WorldWideScience

Sample records for maximum focal depths

  1. High Resolution Depth-Resolved Imaging From Multi-Focal Images for Medical Ultrasound

    DEFF Research Database (Denmark)

    Diamantis, Konstantinos; Dalgarno, Paul A.; Greenaway, Alan H.

    2015-01-01

    An ultrasound imaging technique providing subdiffraction limit axial resolution for point sources is proposed. It is based on simultaneously acquired multi-focal images of the same object, and on the image metric of sharpness. The sharpness is extracted by image data and presents higher values...... calibration curves combined with the use of a maximum-likelihood algorithm is then able to estimate, with high precision, the depth location of any emitter fron each single image. Estimated values are compared with the ground truth demonstrating that an accuracy of 28.6 µm (0.13λ) is achieved for a 4 mm depth...

  2. Focal depth measurement of scanning helium ion microscope

    International Nuclear Information System (INIS)

    Guo, Hongxuan; Itoh, Hiroshi; Wang, Chunmei; Zhang, Han; Fujita, Daisuke

    2014-01-01

    When facing the challenges of critical dimension measurement of complicated nanostructures, such as of the three dimension integrated circuit, characterization of the focal depth of microscopes is important. In this Letter, we developed a method for characterizing the focal depth of a scanning helium ion microscope (HIM) by using an atomic force microscope tip characterizer (ATC). The ATC was tilted in a sample chamber at an angle to the scanning plan. Secondary electron images (SEIs) were obtained at different positions of the ATC. The edge resolution of the SEIs shows the nominal diameters of the helium ion beam at different focal levels. With this method, the nominal shapes of the helium ion beams were obtained with different apertures. Our results show that a small aperture is necessary to get a high spatial resolution and high depth of field images with HIM. This work provides a method for characterizing and improving the performance of HIM.

  3. Improving Focal Depth Estimates: Studies of Depth Phase Detection at Regional Distances

    Science.gov (United States)

    Stroujkova, A.; Reiter, D. T.; Shumway, R. H.

    2006-12-01

    The accurate estimation of the depth of small, regionally recorded events continues to be an important and difficult explosion monitoring research problem. Depth phases (free surface reflections) are the primary tool that seismologists use to constrain the depth of a seismic event. When depth phases from an event are detected, an accurate source depth is easily found by using the delay times of the depth phases relative to the P wave and a velocity profile near the source. Cepstral techniques, including cepstral F-statistics, represent a class of methods designed for the depth-phase detection and identification; however, they offer only a moderate level of success at epicentral distances less than 15°. This is due to complexities in the Pn coda, which can lead to numerous false detections in addition to the true phase detection. Therefore, cepstral methods cannot be used independently to reliably identify depth phases. Other evidence, such as apparent velocities, amplitudes and frequency content, must be used to confirm whether the phase is truly a depth phase. In this study we used a variety of array methods to estimate apparent phase velocities and arrival azimuths, including beam-forming, semblance analysis, MUltiple SIgnal Classification (MUSIC) (e.g., Schmidt, 1979), and cross-correlation (e.g., Cansi, 1995; Tibuleac and Herrin, 1997). To facilitate the processing and comparison of results, we developed a MATLAB-based processing tool, which allows application of all of these techniques (i.e., augmented cepstral processing) in a single environment. The main objective of this research was to combine the results of three focal-depth estimation techniques and their associated standard errors into a statistically valid unified depth estimate. The three techniques include: 1. Direct focal depth estimate from the depth-phase arrival times picked via augmented cepstral processing. 2. Hypocenter location from direct and surface-reflected arrivals observed on sparse

  4. The use of waveform shapes to automatically determine earthquake focal depth

    Science.gov (United States)

    Sipkin, S.A.

    2000-01-01

    Earthquake focal depth is an important parameter for rapidly determining probable damage caused by a large earthquake. In addition, it is significant both for discriminating between natural events and explosions and for discriminating between tsunamigenic and nontsunamigenic earthquakes. For the purpose of notifying emergency management and disaster relief organizations as well as issuing tsunami warnings, potential time delays in determining source parameters are particularly detrimental. We present a method for determining earthquake focal depth that is well suited for implementation in an automated system that utilizes the wealth of broadband teleseismic data that is now available in real time from the global seismograph networks. This method uses waveform shapes to determine focal depth and is demonstrated to be valid for events with magnitudes as low as approximately 5.5.

  5. Electric field depth-focality tradeoff in transcranial magnetic stimulation: simulation comparison of 50 coil designs.

    Science.gov (United States)

    Deng, Zhi-De; Lisanby, Sarah H; Peterchev, Angel V

    2013-01-01

    Various transcranial magnetic stimulation (TMS) coil designs are available or have been proposed. However, key coil characteristics such as electric field focality and attenuation in depth have not been adequately compared. Knowledge of the coil focality and depth characteristics can help TMS researchers and clinicians with coil selection and interpretation of TMS studies. To quantify the electric field focality and depth of penetration of various TMS coils. The electric field distributions induced by 50 TMS coils were simulated in a spherical human head model using the finite element method. For each coil design, we quantified the electric field penetration by the half-value depth, d(1/2), and focality by the tangential spread, S(1/2), defined as the half-value volume (V(1/2)) divided by the half-value depth, S(1/2) = V(1/2)/d(1/2). The 50 TMS coils exhibit a wide range of electric field focality and depth, but all followed a depth-focality tradeoff: coils with larger half-value depth cannot be as focal as more superficial coils. The ranges of achievable d(1/2) are similar between coils producing circular and figure-8 electric field patterns, ranging 1.0-3.5 cm and 0.9-3.4 cm, respectively. However, figure-8 field coils are more focal, having S(1/2) as low as 5 cm(2) compared to 34 cm(2) for circular field coils. For any coil design, the ability to directly stimulate deeper brain structures is obtained at the expense of inducing wider electrical field spread. Novel coil designs should be benchmarked against comparison coils with consistent metrics such as d(1/2) and S(1/2). Copyright © 2013 Elsevier Inc. All rights reserved.

  6. The Effect of Focal Distance, Age, and Brightness on Near-Field Augmented Reality Depth Matching

    OpenAIRE

    Singh, Gujot; Ellis, Stephen R.; Swan II, J. Edward

    2017-01-01

    Many augmented reality (AR) applications operate within near-field reaching distances, and require matching the depth of a virtual object with a real object. The accuracy of this matching was measured in three experiments, which examined the effect of focal distance, age, and brightness, within distances of 33.3 to 50 cm, using a custom-built AR haploscope. Experiment I examined the effect of focal demand, at the levels of collimated (infinite focal distance), consistent with other depth cues...

  7. The maximum economic depth of groundwater abstraction for irrigation

    Science.gov (United States)

    Bierkens, M. F.; Van Beek, L. P.; de Graaf, I. E. M.; Gleeson, T. P.

    2017-12-01

    Over recent decades, groundwater has become increasingly important for agriculture. Irrigation accounts for 40% of the global food production and its importance is expected to grow further in the near future. Already, about 70% of the globally abstracted water is used for irrigation, and nearly half of that is pumped groundwater. In many irrigated areas where groundwater is the primary source of irrigation water, groundwater abstraction is larger than recharge and we see massive groundwater head decline in these areas. An important question then is: to what maximum depth can groundwater be pumped for it to be still economically recoverable? The objective of this study is therefore to create a global map of the maximum depth of economically recoverable groundwater when used for irrigation. The maximum economic depth is the maximum depth at which revenues are still larger than pumping costs or the maximum depth at which initial investments become too large compared to yearly revenues. To this end we set up a simple economic model where costs of well drilling and the energy costs of pumping, which are a function of well depth and static head depth respectively, are compared with the revenues obtained for the irrigated crops. Parameters for the cost sub-model are obtained from several US-based studies and applied to other countries based on GDP/capita as an index of labour costs. The revenue sub-model is based on gross irrigation water demand calculated with a global hydrological and water resources model, areal coverage of crop types from MIRCA2000 and FAO-based statistics on crop yield and market price. We applied our method to irrigated areas in the world overlying productive aquifers. Estimated maximum economic depths range between 50 and 500 m. Most important factors explaining the maximum economic depth are the dominant crop type in the area and whether or not initial investments in well infrastructure are limiting. In subsequent research, our estimates of

  8. Mid-depth temperature maximum in an estuarine lake

    Science.gov (United States)

    Stepanenko, V. M.; Repina, I. A.; Artamonov, A. Yu; Gorin, S. L.; Lykossov, V. N.; Kulyamin, D. V.

    2018-03-01

    The mid-depth temperature maximum (TeM) was measured in an estuarine Bol’shoi Vilyui Lake (Kamchatka peninsula, Russia) in summer 2015. We applied 1D k-ɛ model LAKE to the case, and found it successfully simulating the phenomenon. We argue that the main prerequisite for mid-depth TeM development is a salinity increase below the freshwater mixed layer, sharp enough in order to increase the temperature with depth not to cause convective mixing and double diffusion there. Given that this condition is satisfied, the TeM magnitude is controlled by physical factors which we identified as: radiation absorption below the mixed layer, mixed-layer temperature dynamics, vertical heat conduction and water-sediments heat exchange. In addition to these, we formulate the mechanism of temperature maximum ‘pumping’, resulting from the phase shift between diurnal cycles of mixed-layer depth and temperature maximum magnitude. Based on the LAKE model results we quantify the contribution of the above listed mechanisms and find their individual significance highly sensitive to water turbidity. Relying on physical mechanisms identified we define environmental conditions favouring the summertime TeM development in salinity-stratified lakes as: small-mixed layer depth (roughly, ~wind and cloudless weather. We exemplify the effect of mixed-layer depth on TeM by a set of selected lakes.

  9. Determination of the maximum-depth to potential field sources by a maximum structural index method

    Science.gov (United States)

    Fedi, M.; Florio, G.

    2013-01-01

    A simple and fast determination of the limiting depth to the sources may represent a significant help to the data interpretation. To this end we explore the possibility of determining those source parameters shared by all the classes of models fitting the data. One approach is to determine the maximum depth-to-source compatible with the measured data, by using for example the well-known Bott-Smith rules. These rules involve only the knowledge of the field and its horizontal gradient maxima, and are independent from the density contrast. Thanks to the direct relationship between structural index and depth to sources we work out a simple and fast strategy to obtain the maximum depth by using the semi-automated methods, such as Euler deconvolution or depth-from-extreme-points method (DEXP). The proposed method consists in estimating the maximum depth as the one obtained for the highest allowable value of the structural index (Nmax). Nmax may be easily determined, since it depends only on the dimensionality of the problem (2D/3D) and on the nature of the analyzed field (e.g., gravity field or magnetic field). We tested our approach on synthetic models against the results obtained by the classical Bott-Smith formulas and the results are in fact very similar, confirming the validity of this method. However, while Bott-Smith formulas are restricted to the gravity field only, our method is applicable also to the magnetic field and to any derivative of the gravity and magnetic field. Our method yields a useful criterion to assess the source model based on the (∂f/∂x)max/fmax ratio. The usefulness of the method in real cases is demonstrated for a salt wall in the Mississippi basin, where the estimation of the maximum depth agrees with the seismic information.

  10. Penalized maximum-likelihood sinogram restoration for dual focal spot computed tomography

    International Nuclear Information System (INIS)

    Forthmann, P; Koehler, T; Begemann, P G C; Defrise, M

    2007-01-01

    Due to various system non-idealities, the raw data generated by a computed tomography (CT) machine are not readily usable for reconstruction. Although the deterministic nature of corruption effects such as crosstalk and afterglow permits correction by deconvolution, there is a drawback because deconvolution usually amplifies noise. Methods that perform raw data correction combined with noise suppression are commonly termed sinogram restoration methods. The need for sinogram restoration arises, for example, when photon counts are low and non-statistical reconstruction algorithms such as filtered backprojection are used. Many modern CT machines offer a dual focal spot (DFS) mode, which serves the goal of increased radial sampling by alternating the focal spot between two positions on the anode plate during the scan. Although the focal spot mode does not play a role with respect to how the data are affected by the above-mentioned corruption effects, it needs to be taken into account if regularized sinogram restoration is to be applied to the data. This work points out the subtle difference in processing that sinogram restoration for DFS requires, how it is correctly employed within the penalized maximum-likelihood sinogram restoration algorithm and what impact it has on image quality

  11. Phase pupil functions for focal-depth enhancement derived from a Wigner distribution function.

    Science.gov (United States)

    Zalvidea, D; Sicre, E E

    1998-06-10

    A method for obtaining phase-retardation functions, which give rise to an increase of the image focal depth, is proposed. To this end, the Wigner distribution function corresponding to a specific aperture that has an associated small depth of focus in image space is conveniently sheared in the phase-space domain to generate a new Wigner distribution function. From this new function a more uniform on-axis image irradiance can be accomplished. This approach is illustrated by comparison of the imaging performance of both the derived phase function and a previously reported logarithmic phase distribution.

  12. TRENDS IN ESTIMATED MIXING DEPTH DAILY MAXIMUMS

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, R; Amy DuPont, A; Robert Kurzeja, R; Matt Parker, M

    2007-11-12

    Mixing depth is an important quantity in the determination of air pollution concentrations. Fireweather forecasts depend strongly on estimates of the mixing depth as a means of determining the altitude and dilution (ventilation rates) of smoke plumes. The Savannah River United States Forest Service (USFS) routinely conducts prescribed fires at the Savannah River Site (SRS), a heavily wooded Department of Energy (DOE) facility located in southwest South Carolina. For many years, the Savannah River National Laboratory (SRNL) has provided forecasts of weather conditions in support of the fire program, including an estimated mixing depth using potential temperature and turbulence change with height at a given location. This paper examines trends in the average estimated mixing depth daily maximum at the SRS over an extended period of time (4.75 years) derived from numerical atmospheric simulations using two versions of the Regional Atmospheric Modeling System (RAMS). This allows for differences to be seen between the model versions, as well as trends on a multi-year time frame. In addition, comparisons of predicted mixing depth for individual days in which special balloon soundings were released are also discussed.

  13. Multi-approach analysis of maximum riverbed scour depth above subway tunnel

    Directory of Open Access Journals (Sweden)

    Jun Chen

    2010-12-01

    Full Text Available When subway tunnels are routed underneath rivers, riverbed scour may expose the structure, with potentially severe consequences. Thus, it is important to identify the maximum scour depth to ensure that the designed buried depth is adequate. There are a range of methods that may be applied to this problem, including the fluvial process analysis method, geological structure analysis method, scour formula method, scour model experiment method, and numerical simulation method. However, the application ranges and forecasting precision of these methods vary considerably. In order to quantitatively analyze the characteristics of the different methods, a subway tunnel passing underneath a river was selected, and the aforementioned five methods were used to forecast the maximum scour depth. The fluvial process analysis method was used to characterize the river regime and evolution trend, which were the baseline for examination of the scour depth of the riverbed. The results obtained from the scour model experiment and the numerical simulation methods are reliable; these two methods are suitable for application to tunnel projects passing underneath rivers. The scour formula method was less accurate than the scour model experiment method; it is suitable for application to lower risk projects such as pipelines. The results of the geological structure analysis had low precision; the method is suitable for use as a secondary method to assist other research methods. To forecast the maximum scour depth of the riverbed above the subway tunnel, a combination of methods is suggested, and the appropriate analysis method should be chosen with respect to the local conditions.

  14. A comparison of conventional maximum intensity projection with a new depth-specific topographic mapping technique in the CT analysis of proximal tibial subchondral bone density

    International Nuclear Information System (INIS)

    Johnston, James D.; Kontulainen, Saija A.; Masri, Bassam A.; Wilson, David R.

    2010-01-01

    The objective was to identify subchondral bone density differences between normal and osteoarthritic (OA) proximal tibiae using computed tomography osteoabsorptiometry (CT-OAM) and computed tomography topographic mapping of subchondral density (CT-TOMASD). Sixteen intact cadaver knees from ten donors (8 male:2 female; mean age:77.8, SD:7.4 years) were categorized as normal (n = 10) or OA (n = 6) based upon CT reconstructions. CT-OAM assessed maximum subchondral bone mineral density (BMD). CT-TOMASD assessed average subchondral BMD across three layers (0-2.5, 2.5-5 and 5-10 mm) measured in relation to depth from the subchondral surface. Regional analyses of CT-OAM and CT-TOMASD included: medial BMD, lateral BMD, and average BMD of a 10-mm diameter area that searched each medial and lateral plateau for the highest ''focal'' density present within each knee. Compared with normal knees, both CT-OAM and CT-TOMASD demonstrated an average of 17% greater whole medial compartment density in OA knees (p 0.05). CT-TOMASD focal region analyses revealed an average of 24% greater density in the 0- to 2.5-mm layer (p = 0.003) and 36% greater density in the 2.5- to 5-mm layer (p = 0.034) in OA knees. Both CT-OAM and TOMASD identified higher medial compartment density in OA tibiae compared with normal tibiae. In addition, CT-TOMASD indicated greater focal density differences between normal and OA knees with increased depth from the subchondral surface. Depth-specific density analyses may help identify and quantify small changes in subchondral BMD associated with OA disease onset and progression. (orig.)

  15. Multi-approach analysis of maximum riverbed scour depth above subway tunnel

    OpenAIRE

    Jun Chen; Hong-wu Tang; Zui-sen Li; Wen-hong Dai

    2010-01-01

    When subway tunnels are routed underneath rivers, riverbed scour may expose the structure, with potentially severe consequences. Thus, it is important to identify the maximum scour depth to ensure that the designed buried depth is adequate. There are a range of methods that may be applied to this problem, including the fluvial process analysis method, geological structure analysis method, scour formula method, scour model experiment method, and numerical simulation method. However, the applic...

  16. Assessment of geomechanical properties, maximum depth and excavation damaged zone aspects - Expert report

    International Nuclear Information System (INIS)

    Amann, F.; Löw, S.; Perras, M.

    2015-11-01

    This comprehensive report published by the Swiss National Nuclear Safety Inspectorate ENSI discusses the expert report published on the need for the assessment of geomechanical properties and maximum depth of repositories for high, medium and low-activity nuclear wastes. Also, aspects concerning excavation damaged zones (EDZ) are considered. These are all criteria for the selection of sites as part of Phase 2 of the Swiss waste disposal project. Four questions are examined: are NAGRA’s documented basic considerations and calculations on Opalinus Clay comprehensive enough and correct, are the calculations on maximum depth correct, are the proposed storage perimeters correct with respect to depth and will NAGRA be able to take possible excavation damaged zones (EDZ) into account? Literature and references concerning the subject are quoted

  17. Maximum Neutral Buoyancy Depth of Juvenile Chinook Salmon: Implications for Survival during Hydroturbine Passage

    Energy Technology Data Exchange (ETDEWEB)

    Pflugrath, Brett D.; Brown, Richard S.; Carlson, Thomas J.

    2012-03-01

    This study investigated the maximum depth at which juvenile Chinook salmon Oncorhynchus tshawytscha can acclimate by attaining neutral buoyancy. Depth of neutral buoyancy is dependent upon the volume of gas within the swim bladder, which greatly influences the occurrence of injuries to fish passing through hydroturbines. We used two methods to obtain maximum swim bladder volumes that were transformed into depth estimations - the increased excess mass test (IEMT) and the swim bladder rupture test (SBRT). In the IEMT, weights were surgically added to the fishes exterior, requiring the fish to increase swim bladder volume in order to remain neutrally buoyant. SBRT entailed removing and artificially increasing swim bladder volume through decompression. From these tests, we estimate the maximum acclimation depth for juvenile Chinook salmon is a median of 6.7m (range = 4.6-11.6 m). These findings have important implications to survival estimates, studies using tags, hydropower operations, and survival of juvenile salmon that pass through large Kaplan turbines typical of those found within the Columbia and Snake River hydropower system.

  18. A generic statistical methodology to predict the maximum pit depth of a localized corrosion process

    International Nuclear Information System (INIS)

    Jarrah, A.; Bigerelle, M.; Guillemot, G.; Najjar, D.; Iost, A.; Nianga, J.-M.

    2011-01-01

    Highlights: → We propose a methodology to predict the maximum pit depth in a corrosion process. → Generalized Lambda Distribution and the Computer Based Bootstrap Method are combined. → GLD fit a large variety of distributions both in their central and tail regions. → Minimum thickness preventing perforation can be estimated with a safety margin. → Considering its applications, this new approach can help to size industrial pieces. - Abstract: This paper outlines a new methodology to predict accurately the maximum pit depth related to a localized corrosion process. It combines two statistical methods: the Generalized Lambda Distribution (GLD), to determine a model of distribution fitting with the experimental frequency distribution of depths, and the Computer Based Bootstrap Method (CBBM), to generate simulated distributions equivalent to the experimental one. In comparison with conventionally established statistical methods that are restricted to the use of inferred distributions constrained by specific mathematical assumptions, the major advantage of the methodology presented in this paper is that both the GLD and the CBBM enable a statistical treatment of the experimental data without making any preconceived choice neither on the unknown theoretical parent underlying distribution of pit depth which characterizes the global corrosion phenomenon nor on the unknown associated theoretical extreme value distribution which characterizes the deepest pits. Considering an experimental distribution of depths of pits produced on an aluminium sample, estimations of maximum pit depth using a GLD model are compared to similar estimations based on usual Gumbel and Generalized Extreme Value (GEV) methods proposed in the corrosion engineering literature. The GLD approach is shown having smaller bias and dispersion in the estimation of the maximum pit depth than the Gumbel approach both for its realization and mean. This leads to comparing the GLD approach to the GEV one

  19. Incidental colonic focal FDG uptake on PET/CT: can the maximum standardized uptake value (SUVmax) guide us in the timing of colonoscopy?

    NARCIS (Netherlands)

    van Hoeij, F. B.; Keijsers, R. G. M.; Loffeld, B. C. A. J.; Dun, G.; Stadhouders, P. H. G. M.; Weusten, B. L. A. M.

    2015-01-01

    In patients undergoing F-18-FDG PET/CT, incidental colonic focal lesions can be indicative of inflammatory, premalignant or malignant lesions. The maximum standardized uptake value (SUVmax) of these lesions, representing the FDG uptake intensity, might be helpful in differentiating malignant from

  20. Quadruple Cone Coil with improved focality than Figure-8 coil in Transcranial Magnetic Stimulation

    Science.gov (United States)

    Rastogi, Priyam; Lee, Erik G.; Hadimani, Ravi L.; Jiles, David C.

    Transcranial Magnetic Stimulation (TMS) is a non-invasive therapy which uses a time varying magnetic field to induce an electric field in the brain and to cause neuron depolarization. Magnetic coils play an important role in the TMS therapy since their coil geometry determines the focality and penetration's depth of the induced electric field in the brain. Quadruple Cone Coil (QCC) is a novel coil with an improved focality when compared to commercial Figure-8 coil. The results of this newly designed QCC coil are compared with the Figure-8 coil at two different positions of the head - vertex and dorsolateral prefrontal cortex, over the 50 anatomically realistic MRI derived head models. Parameters such as volume of stimulation, maximum electric, area of stimulation and location of maximum electric field are determined with the help of computer modelling of both coils. There is a decrease in volume of brain stimulated by 11.6 % and a modest improvement of 8 % in the location of maximum electric field due to QCC in comparison to the Figure-8 coil. The Carver Charitable Trust and The Galloway Foundation.

  1. Transcranial Magnetic Stimulation-coil design with improved focality

    Science.gov (United States)

    Rastogi, P.; Lee, E. G.; Hadimani, R. L.; Jiles, D. C.

    2017-05-01

    Transcranial Magnetic Stimulation (TMS) is a technique for neuromodulation that can be used as a non-invasive therapy for various neurological disorders. In TMS, a time varying magnetic field generated from an electromagnetic coil placed on the scalp is used to induce an electric field inside the brain. TMS coil geometry plays an important role in determining the focality and depth of penetration of the induced electric field responsible for stimulation. Clinicians and basic scientists are interested in stimulating a localized area of the brain, while minimizing the stimulation of surrounding neural networks. In this paper, a novel coil has been proposed, namely Quadruple Butterfly Coil (QBC) with an improved focality over the commercial Figure-8 coil. Finite element simulations were conducted with both the QBC and the conventional Figure-8 coil. The two coil's stimulation profiles were assessed with 50 anatomically realistic MRI derived head models. The coils were positioned on the vertex and the scalp over the dorsolateral prefrontal cortex to stimulate the brain. Computer modeling of the coils has been done to determine the parameters of interest-volume of stimulation, maximum electric field, location of maximum electric field and area of stimulation across all 50 head models for both coils.

  2. Controlling dental enamel-cavity ablation depth with optimized stepping parameters along the focal plane normal using a three axis, numerically controlled picosecond laser.

    Science.gov (United States)

    Yuan, Fusong; Lv, Peijun; Wang, Dangxiao; Wang, Lei; Sun, Yuchun; Wang, Yong

    2015-02-01

    The purpose of this study was to establish a depth-control method in enamel-cavity ablation by optimizing the timing of the focal-plane-normal stepping and the single-step size of a three axis, numerically controlled picosecond laser. Although it has been proposed that picosecond lasers may be used to ablate dental hard tissue, the viability of such a depth-control method in enamel-cavity ablation remains uncertain. Forty-two enamel slices with approximately level surfaces were prepared and subjected to two-dimensional ablation by a picosecond laser. The additive-pulse layer, n, was set to 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70. A three-dimensional microscope was then used to measure the ablation depth, d, to obtain a quantitative function relating n and d. Six enamel slices were then subjected to three dimensional ablation to produce 10 cavities, respectively, with additive-pulse layer and single-step size set to corresponding values. The difference between the theoretical and measured values was calculated for both the cavity depth and the ablation depth of a single step. These were used to determine minimum-difference values for both the additive-pulse layer (n) and single-step size (d). When the additive-pulse layer and the single-step size were set 5 and 45, respectively, the depth error had a minimum of 2.25 μm, and 450 μm deep enamel cavities were produced. When performing three-dimensional ablating of enamel with a picosecond laser, adjusting the timing of the focal-plane-normal stepping and the single-step size allows for the control of ablation-depth error to the order of micrometers.

  3. ABOUT RATIONING MAXIMUM ALLOWABLE DEFECT DEPTH ON THE SURFACE OF STEEL BILLETS IN PRODUCTION OF HOT-ROLLED STEEL

    Directory of Open Access Journals (Sweden)

    PARUSOV E. V.

    2017-01-01

    Full Text Available Formulation of the problem. Significant influence on the quality of rolled steel have various defects on its surface, which in its turn inherited from surface defects of billet and possible damage to the surface of rolled steel in the rolling mill line. One of the criteria for assessing the quality indicators of rolled steel is rationing of surface defects [1; 2; 3; 6; 7]. Current status of the issue. Analyzing the different requirements of regulations to the surface quality of the rolled high-carbon steels, we can conclude that the maximum allowable depth of defects on the surface of billet should be in the range of 2.0...5.0 mm (depending on the section of the billet, method of its production and further the destination Purpose. Develop a methodology for calculating the maximum allowable depth of defects on the steel billet surface depending on the requirements placed on the surface quality of hot-rolled steel. Results. A simplified method of calculation, allowing at the rated depth of defects on the surface of the hot-rolled steel to make operatively calculation of the maximum allowable depth of surface defects of steel billets before heating the metal in the heat deformation was developed. The findings shows that the maximum allowable depth of surface defects is reduced with increasing diameter rolled steel, reducing the initial section steel billet and degrees of oxidation of the metal in the heating furnace.

  4. Dual-layer electrode-driven liquid crystal lens with electrically tunable focal length and focal plane

    Science.gov (United States)

    Zhang, Y. A.; Lin, C. F.; Lin, J. P.; Zeng, X. Y.; Yan, Q.; Zhou, X. T.; Guo, T. L.

    2018-04-01

    Electric-field-driven liquid crystal (ELC) lens with tunable focal length and their depth of field has been extensively applied in 3D display and imaging systems. In this work, a dual-layer electrode-driven liquid crystal (DELC) lens with electrically tunable focal length and controllable focal plane is demonstrated. ITO-SiO2-AZO electrodes with the dual-layer staggered structure on the top substrate are used as driven electrodes within a LC cell, which permits the establishment of an alternative controllability. The focal length of the DELC lens can be adjusted from 1.41 cm to 0.29 cm when the operating voltage changes from 15 V to 40 V. Furthermore, the focal plane of the DELC lens can selectively move by changing the driving method of the applied voltage to the next driven electrodes. This work demonstrates that the DELC lens has potential applications in imaging systems because of electrically tunable focal length and controllable focal plane.

  5. The Hengill geothermal area, Iceland: Variation of temperature gradients deduced from the maximum depth of seismogenesis

    Science.gov (United States)

    Foulger, G. R.

    1995-04-01

    Given a uniform lithology and strain rate and a full seismic data set, the maximum depth of earthquakes may be viewed to a first order as an isotherm. These conditions are approached at the Hengill geothermal area S. Iceland, a dominantly basaltic area. The likely strain rate calculated from thermal and tectonic considerations is 10 -15 s -1, and temperature measurements from four drill sites within the area indicate average, near-surface geothermal gradients of up to 150 °C km -1 throughout the upper 2 km. The temperature at which seismic failure ceases for the strain rates likely at the Hengill geothermal area is determined by analogy with oceanic crust, and is about 650 ± 50 °C. The topographies of the top and bottom of the seismogenic layer were mapped using 617 earthquakes located highly accurately by performing a simultaneous inversion for three-dimensional structure and hypocentral parameters. The thickness of the seismogenic layer is roughly constant and about 3 km. A shallow, aseismic, low-velocity volume within the spreading plate boundary that crosses the area occurs above the top of the seismogenic layer and is interpreted as an isolated body of partial melt. The base of the seismogenic layer has a maximum depth of about 6.5 km beneath the spreading axis and deepens to about 7 km beneath a transform zone in the south of the area. Beneath the high-temperature part of the geothermal area, the maximum depth of earthquakes may be as shallow as 4 km. The geothermal gradient below drilling depths in various parts of the area ranges from 84 ± 9 °Ckm -1 within the low-temperature geothermal area of the transform zone to 138 ± 15 °Ckm -1 below the centre of the high-temperature geothermal area. Shallow maximum depths of earthquakes and therefore high average geothermal gradients tend to correlate with the intensity of the geothermal area and not with the location of the currently active spreading axis.

  6. Earthquake focal mechanism forecasting in Italy for PSHA purposes

    Science.gov (United States)

    Roselli, Pamela; Marzocchi, Warner; Mariucci, Maria Teresa; Montone, Paola

    2018-01-01

    In this paper, we put forward a procedure that aims to forecast focal mechanism of future earthquakes. One of the primary uses of such forecasts is in probabilistic seismic hazard analysis (PSHA); in fact, aiming at reducing the epistemic uncertainty, most of the newer ground motion prediction equations consider, besides the seismicity rates, the forecast of the focal mechanism of the next large earthquakes as input data. The data set used to this purpose is relative to focal mechanisms taken from the latest stress map release for Italy containing 392 well-constrained solutions of events, from 1908 to 2015, with Mw ≥ 4 and depths from 0 down to 40 km. The data set considers polarity focal mechanism solutions until to 1975 (23 events), whereas for 1976-2015, it takes into account only the Centroid Moment Tensor (CMT)-like earthquake focal solutions for data homogeneity. The forecasting model is rooted in the Total Weighted Moment Tensor concept that weighs information of past focal mechanisms evenly distributed in space, according to their distance from the spatial cells and magnitude. Specifically, for each cell of a regular 0.1° × 0.1° spatial grid, the model estimates the probability to observe a normal, reverse, or strike-slip fault plane solution for the next large earthquakes, the expected moment tensor and the related maximum horizontal stress orientation. These results will be available for the new PSHA model for Italy under development. Finally, to evaluate the reliability of the forecasts, we test them with an independent data set that consists of some of the strongest earthquakes with Mw ≥ 3.9 occurred during 2016 in different Italian tectonic provinces.

  7. Focal depth measurements of the vaginal wall: a new method to noninvasively quantify vaginal wall thickness in the diagnosis and treatment of vaginal atrophy

    NARCIS (Netherlands)

    Weber, Maaike A.; Diedrich, Chantal M.; Ince, Can; Roovers, Jan-Paul

    2016-01-01

    The aim of the study was to evaluate if vaginal focal depth measurement could be a noninvasive method to quantify vaginal wall thickness. Postmenopausal women undergoing topical estrogen therapy because of vaginal atrophy (VA) were recruited. VA was diagnosed based on the presence of symptoms and

  8. Comprehensive Survey on Improved Focality and Penetration Depth of Transcranial Magnetic Stimulation Employing Multi-Coil Arrays

    Directory of Open Access Journals (Sweden)

    Xile Wei

    2017-11-01

    Full Text Available Multi-coil arrays applied in transcranial magnetic stimulation (TMS are proposed to accurately stimulate brain tissues and modulate neural activities by an induced electric field (EF. Composed of numerous independently driven coils, a multi-coil array has alternative energizing strategies to evoke EFs targeting at different cerebral regions. To improve the locating resolution and the stimulating focality, we need to fully understand the variation properties of induced EFs and the quantitative control method of the spatial arrangement of activating coils, both of which unfortunately are still unclear. In this paper, a comprehensive analysis of EF properties was performed based on multi-coil arrays. Four types of planar multi-coil arrays were used to study the relationship between the spatial distribution of EFs and the structure of stimuli coils. By changing coil-driven strategies in a basic 16-coil array, we find that an EF induced by compactly distributed coils decays faster than that induced by dispersedly distributed coils, but the former has an advantage over the latter in terms of the activated brain volume. Simulation results also indicate that the attenuation rate of an EF induced by the 36-coil dense array is 3 times and 1.5 times greater than those induced by the 9-coil array and the 16-coil array, respectively. The EF evoked by the 36-coil dispense array has the slowest decay rate. This result demonstrates that larger multi-coil arrays, compared to smaller ones, activate deeper brain tissues at the expense of decreased focality. A further study on activating a specific field of a prescribed shape and size was conducted based on EF variation. Accurate target location was achieved with a 64-coil array 18 mm in diameter. A comparison between the figure-8 coil, the planar array, and the cap-formed array was made and demonstrates an improvement of multi-coil configurations in the penetration depth and the focality. These findings suggest

  9. Comprehensive Survey on Improved Focality and Penetration Depth of Transcranial Magnetic Stimulation Employing Multi-Coil Arrays.

    Science.gov (United States)

    Wei, Xile; Li, Yao; Lu, Meili; Wang, Jiang; Yi, Guosheng

    2017-11-14

    Multi-coil arrays applied in transcranial magnetic stimulation (TMS) are proposed to accurately stimulate brain tissues and modulate neural activities by an induced electric field (EF). Composed of numerous independently driven coils, a multi-coil array has alternative energizing strategies to evoke EFs targeting at different cerebral regions. To improve the locating resolution and the stimulating focality, we need to fully understand the variation properties of induced EFs and the quantitative control method of the spatial arrangement of activating coils, both of which unfortunately are still unclear. In this paper, a comprehensive analysis of EF properties was performed based on multi-coil arrays. Four types of planar multi-coil arrays were used to study the relationship between the spatial distribution of EFs and the structure of stimuli coils. By changing coil-driven strategies in a basic 16-coil array, we find that an EF induced by compactly distributed coils decays faster than that induced by dispersedly distributed coils, but the former has an advantage over the latter in terms of the activated brain volume. Simulation results also indicate that the attenuation rate of an EF induced by the 36-coil dense array is 3 times and 1.5 times greater than those induced by the 9-coil array and the 16-coil array, respectively. The EF evoked by the 36-coil dispense array has the slowest decay rate. This result demonstrates that larger multi-coil arrays, compared to smaller ones, activate deeper brain tissues at the expense of decreased focality. A further study on activating a specific field of a prescribed shape and size was conducted based on EF variation. Accurate target location was achieved with a 64-coil array 18 mm in diameter. A comparison between the figure-8 coil, the planar array, and the cap-formed array was made and demonstrates an improvement of multi-coil configurations in the penetration depth and the focality. These findings suggest that there is a

  10. Effects of countermovement depth on kinematic and kinetic patterns of maximum vertical jumps.

    Science.gov (United States)

    Mandic, Radivoj; Jakovljevic, Sasa; Jaric, Slobodan

    2015-04-01

    Although maximum height (H(max)), muscle force (F), and power output (P), have been routinely obtained from maximum vertical jumps for various purposes, a possible role of the countermovement depth (H(cmd)) on the same variables remains largely unexplored. Here we hypothesized that (1) the optimum H(cmd) for maximizing H(max) exists, while (2) an increase in H(cmd) would be associated with a decrease in both F and P. Professional male basketball players (N=11) preformed maximum countermovement jumps with and without arm swing while varying H(cmd)±25 cm from its preferred value. Although regression models revealed a presence of optimum H(cmd) for maximizing H(max), H(max) revealed only small changes within a wide range of H(cmd). The preferred H(cmd) was markedly below its optimum value (p vertical jumps should be taken with caution since both of them could be markedly confounded by H(cmd). Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. RAPID DETERMINATION OF FOCAL DEPTH USING A GLOBAL NETWORK OF SMALL-APERTURE SEISMIC ARRAYS

    Science.gov (United States)

    Seats, K.; Koper, K.; Benz, H.

    2009-12-01

    The National Earthquake Information Center (NEIC) of the United States Geological Survey (USGS) operates 24 hours a day, 365 days a year with the mission of locating and characterizing seismic events around the world. A key component of this task is quickly determining the focal depth of each seismic event, which has a first-order effect on estimates of ground shaking used in the impact assessment applications of emergency response activities. Current methods of depth estimation used at the NEIC include arrival time inversion both with and without depth phases, a Bayesian depth constraint based on historical seismicity (1973-present), and moment tensor inversion primarily using P- and S-wave waveforms. In this study, we explore the possibility of automated modeling of waveforms from vertical-component arrays of the International Monitoring System (IMS) to improve rapid depth estimation at NEIC. Because these arrays are small-aperture, they are effective at increasing signal to noise ratios for frequencies of 1 Hz and higher. Currently, NEIC receives continuous real-time data from 23 IMS arrays. Following work done by previous researchers, we developed a technique that acts as an array of arrays. For a given epicentral location we calculate fourth root beams for each IMS array in the distance range of 30 to 95 degrees at the expected slowness vector of the first arrival. Because the IMS arrays are small-aperture, these beams highlight energy that has slowness similar to the first arrival, such as depth phases. The beams are rectified by taking the envelope and then automatically aligned on the largest peak within 5 seconds of the expected arrival time. The station beams are then combined into network beams assuming a range of depths varying from 10 km to 700 km in increments of 1 km. The network beams are computed assuming both pP and sP propagation, and a measure of beam power is output as a function of depth for both propagation models, as well as their sum. We

  12. On the applicability of extreme value statistics in the prediction of maximum pit depth in heavily corroded non-piggable buried pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Alfonso, L. [Universidad Autonoma de la Ciudad de Mexico, Mexico D.F. 09790 (Mexico); Caleyo, F.; Hallen, J. M.; Araujo, J. [ESIQIE, Instituto Politecnico Nacional, Mexico D.F. (Mexico)

    2010-07-01

    Pitting corrosion entails serious risks in industrial plants, since a perforation resulting from a single pit can cause the failure of in-service components like water pipes, heat exchangers or oil tanks. A number of statistical methods have been suggested to estimate the maximum pit depth. Over the years, a successful application of extreme value analysis has been found in the application of the Gumbel distribution to predict the maximum pit depth from a smaller number of samples with small area. There is a lack of studies devoted to the applicability of the Gumbel method to the prediction of maximum pitting-corrosion depth. The aim of the work presented in this paper is to introduce a new strategy for the application of the Gumbel method in real pipelines. The methodology proposed is based on the fact that the clustered pattern of the pit depth distribution is less pronounced when the analysis is restricted to sections of the pipeline that exhibits similar characteristics.

  13. Measurement of the Depth of Maximum of Extensive Air Showers above 10(18) eV

    NARCIS (Netherlands)

    Abraham, J.; Abreu, P.; Aglietta, M.; Ahn, E. J.; Allard, D.; Allekotte, I.; Allen, J.; Alvarez-Muniz, J.; Ambrosio, M.; Anchordoqui, L.; Andringa, S.; Anticic, T.; Anzalone, A.; Aramo, C.; Arganda, E.; Arisaka, K.; Arqueros, F.; Asorey, H.; Assis, P.; Aublin, J.; Ave, M.; Avila, G.; Baecker, T.; Badagnani, D.; Balzer, M.; Barber, K. B.; Barroso, S. L. C.; Barbosa, A. F.; Baughman, B.; Bauleo, P.; Beatty, J. J.; Becker, B. R.; Becker, K. H.; Belletoile, A.; Bellido, J. A.; BenZvi, S.; Berat, C.; Bergmann, T.; Bertou, X.; Biermann, P. L.; Billoir, P.; Blanch-Bigas, O.; Blanco, F.; Blanco, M.; Bleve, C.; Bluemer, H.; Bohacova, M.; Boncioli, D.; Bonifazi, C.; Bonino, R.; Borodai, N.; Brack, J.; Brogueira, P.; Brown, W. C.; Bruijn, R.; Buchholz, P.; Bueno, A.; Burton, R. E.; Busca, N. G.; Caballero-Mora, K. S.; Caramete, L.; Caruso, R.; Castellina, A.; Catalano, O.; Cataldi, G.; Cazon, L.; Cester, R.; Chauvin, J.; Chiavassa, A.; Chinellato, J. A.; Chou, A.; Chudoba, J.; Clay, R. W.; Colombo, E.; Coluccia, M. R.; Conceicao, R.; Contreras, F.; Cook, H.; Cooper, M. J.; Coppens, J.; Cordier, A.; Cotti, U.; Coutu, S.; Covault, C. E.; Creusot, A.; Criss, A.; Cronin, J.; Curutiu, A.; Dagoret-Campagne, S.; Dallier, R.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; De Domenico, M.; De Donato, C.; de Jong, S. J.; De la Vega, G.; de Mello Junior, W. J. M.; de Mello Neto, J. R. T.; De Mitri, I.; de Souza, V.; de Vries, K. D.; Decerprit, G.; del Peral, L.; Deligny, O.; Della Selva, A.; Delle Fratte, C.; Dembinski, H.; Di Giulio, C.; Diaz, J. C.; Diaz Castro, M. L.; Diep, P. N.; Dobrigkeit, C.; D'Olivo, J. C.; Dong, P. N.; Dorofeev, A.; dos Anjos, J. C.; Dova, M. T.; D'Urso, D.; Dutan, I.; DuVernois, M. A.; Ebr, J.; Engel, R.; Erdmann, M.; Escobar, C. O.; Etchegoyen, A.; Facal San Luis, P.; Falcke, H.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Ferrero, A.; Fick, B.; Filevich, A.; Filipcic, A.; Fleck, I.; Fliescher, S.; Fracchiolla, C. E.; Fraenkel, E. D.; Froehlich, U.; Fulgione, W.; Gamarra, R. F.; Gambetta, S.; Garcia, B.; Garcia Gamez, D.; Garcia-Pinto, D.; Garrido, X.; Gelmini, G.; Gemmeke, H.; Ghia, P. L.; Giaccari, U.; Giller, M.; Glass, H.; Goggin, L. M.; Gold, M. S.; Golup, G.; Gomez Albarracin, F.; Gomez Berisso, M.; Goncalves, P.; Gonzalez, D.; Gonzalez, J. G.; Gora, D.; Gorgi, A.; Gouffon, P.; Gozzini, S. R.; Grashorn, E.; Grebe, S.; Grigat, M.; Grillo, A. F.; Guardincerri, Y.; Guarino, F.; Guedes, G. P.; Hague, J. D.; Halenka, V.; Hansen, P.; Harari, D.; Harmsma, S.; Harton, J. L.; Haungs, A.; Hebbeker, T.; Heck, D.; Herve, A. E.; Hojvat, C.; Holmes, V. C.; Homola, P.; Horandel, J. R.; Horneffer, A.; Hrabovsky, M.; Huege, T.; Hussain, M.; Iarlori, M.; Insolia, A.; Ionita, F.; Italiano, A.; Jiraskova, S.; Kadija, K.; Kaducak, M.; Kampert, K. H.; Karova, T.; Kasper, P.; Kegl, B.; Keilhauer, B.; Keivani, A.; Kelley, J.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Knapik, R.; Knapp, J.; Koang, D. -H.; Krieger, A.; Kroemer, O.; Kruppke-Hansen, D.; Kuehn, F.; Kuempel, D.; Kulbartz, K.; Kunka, N.; Kusenko, A.; La Rosa, G.; Lachaud, C.; Lago, B. L.; Lautridou, P.; Leao, M. S. A. B.; Lebrun, D.; Lebrun, P.; Lee, J.; Leigui de Oliveira, M. A.; Lemiere, A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Lopez, R.; Lopez Agueera, A.; Louedec, K.; Lozano Bahilo, J.; Lucero, A.; Ludwig, M.; Lyberis, H.; Maccarone, M. C.; Macolino, C.; Maldera, S.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Marin, V.; Maris, I. C.; Marquez Falcon, H. R.; Marsella, G.; Martello, D.; Martinez Bravo, O.; Mathes, H. J.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Maurizio, D.; Mazur, P. O.; McEwen, M.; Medina-Tanco, G.; Melissas, M.; Melo, D.; Menichetti, E.; Menshikov, A.; Meurer, C.; Micanovic, S.; Micheletti, M. I.; Miller, W.; Miramonti, L.; Mollerach, S.; Monasor, M.; Ragaigne, D. Monnier; Montanet, F.; Morales, B.; Morello, C.; Moreno, E.; Moreno, J. C.; Morris, C.; Mostafa, M.; Mueller, S.; Muller, M. A.; Mussa, R.; Navarra, G.; Navarro, J. L.; Navas, S.; Necesal, P.; Nellen, L.; Nhung, P. T.; Nierstenhoefer, N.; Nitz, D.; Nosek, D.; Nozka, L.; Nyklicek, M.; Oehlschlaeger, J.; Olinto, A.; Oliva, P.; Olmos-Gilbaja, V. M.; Ortiz, M.; Pacheco, N.; Pakk Selmi-Dei, D.; Palatka, M.; Pallotta, J.; Palmieri, N.; Parente, G.; Parizot, E.; Parlati, S.; Parra, A.; Parrisius, J.; Parsons, R. D.; Pastor, S.; Paul, T.; Pavlidou, V.; Payet, K.; Pech, M.; Pekala, J.; Pelayo, R.; Pepe, I. M.; Perrone, L.; Pesce, R.; Petermann, E.; Petrera, S.; Petrinca, P.; Petrolini, A.; Petrov, Y.; Petrovic, J.; Pfendner, C.; Piegaia, R.; Pierog, T.; Pimenta, M.; Pirronello, V.; Platino, M.; Ponce, V. H.; Pontz, M.; Privitera, P.; Prouza, M.; Quel, E. J.; Rautenberg, J.; Ravel, O.; Ravignani, D.; Redondo, A.; Revenu, B.; Rezende, F. A. S.; Ridky, J.; Riggi, S.; Risse, M.; Ristori, P.; Riviere, C.; Rizi, V.; Robledo, C.; Rodriguez, G.; Rodriguez Martino, J.; Rodriguez Rojo, J.; Rodriguez-Cabo, I.; Rodriguez-Frias, M. D.; Ros, G.; Rosado, J.; Rossler, T.; Roth, M.; Rouille-d'Orfeuil, B.; Roulet, E.; Rovero, A. C.; Salamida, F.; Salazar, H.; Salina, G.; Sanchez, F.; Santander, M.; Santo, C. E.; Santos, E.; Santos, E. M.; Sarazin, F.; Sarkar, S.; Sato, R.; Scharf, N.; Scherini, V.; Schieler, H.; Schiffer, P.; Schmidt, A.; Schmidt, F.; Schmidt, T.; Scholten, O.; Schoorlemmer, H.; Schovancova, J.; Schovanek, P.; Schroeder, F.; Schulte, S.; Schuessler, F.; Schuster, D.; Sciutto, S. J.; Scuderi, M.; Segreto, A.; Semikoz, D.; Settimo, M.; Shadkam, A.; Shellard, R. C.; Sidelnik, I.; Siffert, B. B.; Sigl, G.; Smialkowski, A.; Smida, R.; Snow, G. R.; Sommers, P.; Sorokin, J.; Spinka, H.; Squartini, R.; Stasielak, J.; Stephan, M.; Strazzeri, E.; Stutz, A.; Suarez, F.; Suomijarvi, T.; Supanitsky, A. D.; Susa, T.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Tamashiro, A.; Tamburro, A.; Tapia, A.; Tarutina, T.; Tascau, O.; Tcaciuc, R.; Tcherniakhovski, D.; Tegolo, D.; Thao, N. T.; Thomas, D.; Tiffenberg, J.; Timmermans, C.; Tkaczyk, W.; Todero Peixoto, C. J.; Tome, B.; Tonachini, A.; Travnicek, P.; Tridapalli, D. B.; Tristram, G.; Trovato, E.; Tueros, M.; Ulrich, R.; Unger, M.; Urban, M.; Valdes Galicia, J. F.; Valino, I.; Valore, L.; van den Berg, A. M.; Vazquez, J. R.; Vazquez, R. A.; Veberic, D.; Venters, T.; Verzi, V.; Videla, M.; Villasenor, L.; Vorobiov, S.; Voyvodic, L.; Wahlberg, H.; Wahrlich, P.; Wainberg, O.; Warner, D.; Watson, A. A.; Westerhoff, S.; Whelan, B. J.; Wieczorek, G.; Wiencke, L.; Wilczynska, B.; Wilczynski, H.; Williams, C.; Winchen, T.; Winnick, M. G.; Wundheiler, B.; Yamamoto, T.; Younk, P.; Yuan, G.; Yushkov, A.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zaw, I.; Zepeda, A.; Ziolkowski, M.

    2010-01-01

    We describe the measurement of the depth of maximum, X-max, of the longitudinal development of air showers induced by cosmic rays. Almost 4000 events above 10(18) eV observed by the fluorescence detector of the Pierre Auger Observatory in coincidence with at least one surface detector station are

  14. At site and regional analysis of maximum annual and seasonal discharges and precipitation depths in the upper Hron region

    International Nuclear Information System (INIS)

    Kohnova, S.; Hlavcova, K.

    2004-01-01

    In this presentation authors deal with the regional analysis of maximum annual and seasonal discharges and precipitation depths in the upper Hron region (Slovak Republic). This work has two objectives: (1) At site and regional analysis of annual and seasonal maximum design discharges in the upper Hron region; (2) Analysis of annual and seasonal maximum design precipitations in the connection of extreme runoff condition in the upper Hron region

  15. The Hengill geothermal area, Iceland: variation of temperature gradients deduced from the maximum depth of seismogenesis

    Science.gov (United States)

    Foulger, G.R.

    1995-01-01

    Given a uniform lithology and strain rate and a full seismic data set, the maximum depth of earthquakes may be viewed to a first order as an isotherm. These conditions are approached at the Hengill geothermal area, S. Iceland, a dominantly basaltic area. The temperature at which seismic failure ceases for the strain rates likely at the Hengill geothermal area is determined by analogy with oceanic crust, and is about 650 ?? 50??C. The topographies of the top and bottom of the seismogenic layer were mapped using 617 earthquakes. The thickness of the seismogenic layer is roughly constant and about 3 km. A shallow, aseismic, low-velocity volume within the spreading plate boundary that crosses the area occurs above the top of the seismogenic layer and is interpreted as an isolated body of partial melt. The base of the seismogenic layer has a maximum depth of about 6.5 km beneath the spreading axis and deepens to about 7 km beneath a transform zone in the south of the area. -from Author

  16. Nanometric depth resolution from multi-focal images in microscopy.

    Science.gov (United States)

    Dalgarno, Heather I C; Dalgarno, Paul A; Dada, Adetunmise C; Towers, Catherine E; Gibson, Gavin J; Parton, Richard M; Davis, Ilan; Warburton, Richard J; Greenaway, Alan H

    2011-07-06

    We describe a method for tracking the position of small features in three dimensions from images recorded on a standard microscope with an inexpensive attachment between the microscope and the camera. The depth-measurement accuracy of this method is tested experimentally on a wide-field, inverted microscope and is shown to give approximately 8 nm depth resolution, over a specimen depth of approximately 6 µm, when using a 12-bit charge-coupled device (CCD) camera and very bright but unresolved particles. To assess low-flux limitations a theoretical model is used to derive an analytical expression for the minimum variance bound. The approximations used in the analytical treatment are tested using numerical simulations. It is concluded that approximately 14 nm depth resolution is achievable with flux levels available when tracking fluorescent sources in three dimensions in live-cell biology and that the method is suitable for three-dimensional photo-activated localization microscopy resolution. Sub-nanometre resolution could be achieved with photon-counting techniques at high flux levels.

  17. A new method for depth profiling reconstruction in confocal microscopy

    Science.gov (United States)

    Esposito, Rosario; Scherillo, Giuseppe; Mensitieri, Giuseppe

    2018-05-01

    Confocal microscopy is commonly used to reconstruct depth profiles of chemical species in multicomponent systems and to image nuclear and cellular details in human tissues via image intensity measurements of optical sections. However, the performance of this technique is reduced by inherent effects related to wave diffraction phenomena, refractive index mismatch and finite beam spot size. All these effects distort the optical wave and cause an image to be captured of a small volume around the desired illuminated focal point within the specimen rather than an image of the focal point itself. The size of this small volume increases with depth, thus causing a further loss of resolution and distortion of the profile. Recently, we proposed a theoretical model that accounts for the above wave distortion and allows for a correct reconstruction of the depth profiles for homogeneous samples. In this paper, this theoretical approach has been adapted for describing the profiles measured from non-homogeneous distributions of emitters inside the investigated samples. The intensity image is built by summing the intensities collected from each of the emitters planes belonging to the illuminated volume, weighed by the emitters concentration. The true distribution of the emitters concentration is recovered by a new approach that implements this theoretical model in a numerical algorithm based on the Maximum Entropy Method. Comparisons with experimental data and numerical simulations show that this new approach is able to recover the real unknown concentration distribution from experimental profiles with an accuracy better than 3%.

  18. Spatio-temporal distribution of Diaphanosoma brachyurum (Cladocera: Sididae in freshwater reservoir ecosystems: importance of maximum water depth and macrophyte beds for avoidance of fish predation

    Directory of Open Access Journals (Sweden)

    Jong-Yun Choi

    2014-10-01

    Full Text Available In empirical studies, Cladocera is commonly utilized as a primary food source for predators such as fish, thus, predator avoidance are important strategies to sustain their population in freshwater ecosystems. In this study, we tested the hypothesis that water depth is an important factor in determining the spatial distribution of Diaphanosoma brachyurum Liévin, 1848 in response to fish predation. Quarterly monitoring was implemented at three water layers (i.e., water surface and middle and bottom layers in 21 reservoirs located in the southeastern part of South Korea. D. brachyurum individuals were frequently observed at the study sites and exhibited different spatial patterns of distribution in accordance with the maximum depth of the reservoirs. In the reservoirs with a maximum depth of more than 6 m, high densities of D. brachyurum were observed in the bottom layers; however, in the shallower reservoirs (maximum depth <6 m, D. brachyurum were concentrated in the surface layer. Moreover, during additional surveys, we observed a trend in which D. brachyurum densities increased as the maximum depth or macrophyte biomass increased. Gut contents analysis revealed that predatory fishes in each reservoir frequently consumed D. brachyurum; however, the consumption rate abruptly decreased in reservoirs where the maximum depth was more than 11 m or in the shallow reservoirs supporting a macrophyte bed. Interestingly, the reservoirs more than 11-m depth supported high densities of D. brachyurum in the bottom layer and in the surface macrophyte bed. Based on these results, reservoirs with a maximum depth of more than 11 m or those with a macrophyte bed may provide a refuge for D. brachyurum to avoid fish predation. Compared with other cladoceran species, D. brachyurum readily exploits various types of refugia (in this study, the deep layer or surface macrophyte bed, which may help explain why this species is abundant in various types of reservoirs.

  19. Countermovement depth - a variable which clarifies the relationship between the maximum power output and height of a vertical jump.

    Science.gov (United States)

    Gajewski, Jan; Michalski, Radosław; Buśko, Krzysztof; Mazur-Różycka, Joanna; Staniak, Zbigniew

    2018-01-01

    The aim of this study was to identify the determinants of peak power achieved during vertical jumps in order to clarify relationship between the height of jump and the ability to exert maximum power. One hundred young (16.8±1.8 years) sportsmen participated in the study (body height 1.861 ± 0.109 m, body weight 80.3 ± 9.2 kg). Each participant performed three jump tests: countermovement jump (CMJ), akimbo countermovement jump (ACMJ), and spike jump (SPJ). A force plate was used to measure ground reaction force and to determine peak power output. The following explanatory variables were included in the model: jump height, body mass, and the lowering of the centre of mass before launch (countermovement depth). A model was created using multiple regression analysis and allometric scaling. The model was used to calculate the expected power value for each participant, which correlated strongly with real values. The value of the coefficient of determination R2 equalled 0.89, 0.90 and 0.98, respectively, for the CMJ, ACMJ, and SPJ jumps. The countermovement depth proved to be a variable strongly affecting the maximum power of jump. If the countermovement depth remains constant, the relative peak power is a simple function of jump height. The results suggest that the jump height of an individual is an exact indicator of their ability to produce maximum power. The presented model has a potential to be utilized under field condition for estimating the maximum power output of vertical jumps.

  20. Clinical Significance of Focal Breast Lesions Incidentally Identified by 18F-FDG PET/CT

    International Nuclear Information System (INIS)

    Cho, Young Seok; Choi, Joon Young; Lee, Su Jin; Hyun, Seung Hyup; Lee, Ji Young; Choi, Yong; Choe, Yearn Seong; Lee, Kyung Han; Kim, Byung Tae

    2008-01-01

    We evaluated the incidence and malignant risk of focal breast lesions incidentally detected by 18 F-FDG PET/CT. Various PET/CT findings of the breast lesions were also analyzed to improve the differentiation between benign from malignant focal breast lesions. The subjects were 3,768 consecutive 18 F-FDG PET/CT exams performed in adult females without a history of breast cancer. A focal breast lesion was defined as a focal 18 F-FDG uptake or a focal nodular lesion on CT image irrespective of 18 F-FDG uptake in the breasts. The maximum SUV and CT pattern of focal breast lesions were evaluated, and were compared with final diagnosis. The incidence of focal breast lesions on PET/CT in adult female subjects was 1.4% (58 lesions in 53 subjects). In finally confirmed 53 lesions of 48 subjects, 11 lesions of 8 subjects (20.8%) were proven to be malignant. When the PET/CT patterns suggesting benignancy (maximum attenuation value > 75 HU or 20) were added as diagnostic criteria of PET/CT to differentiate benign from malignant breast lesions along with maximum SUV, the area under ROC curve of PET/CT was significantly increased compared with maximum SUV alone (0.680±0.093 vs. 0.786±0.076, p 18 F-FDG PET/CT is not low, deserving further diagnostic confirmation. Image interpretation considering both 18 F-FDG uptake and PET/CT pattern may be helpful to improve the differentiation from malignant and benign focal breast lesion

  1. Control strategy of maximum vertical jumps: The preferred countermovement depth may not be fully optimized for jump height

    Directory of Open Access Journals (Sweden)

    Mandic Radivoj

    2016-09-01

    Full Text Available The aim of the present study was to explore the control strategy of maximum countermovement jumps regarding the preferred countermovement depth preceding the concentric jump phase. Elite basketball players and physically active non-athletes were tested on the jumps performed with and without an arm swing, while the countermovement depth was varied within the interval of almost 30 cm around its preferred value. The results consistently revealed 5.1-11.2 cm smaller countermovement depth than the optimum one, but the same difference was more prominent in non-athletes. In addition, although the same differences revealed a marked effect on the recorded force and power output, they reduced jump height for only 0.1-1.2 cm. Therefore, the studied control strategy may not be based solely on the countermovement depth that maximizes jump height. In addition, the comparison of the two groups does not support the concept of a dual-task strategy based on the trade-off between maximizing jump height and minimizing the jumping quickness that should be more prominent in the athletes that routinely need to jump quickly. Further research could explore whether the observed phenomenon is based on other optimization principles, such as the minimization of effort and energy expenditure. Nevertheless, future routine testing procedures should take into account that the control strategy of maximum countermovement jumps is not fully based on maximizing the jump height, while the countermovement depth markedly confound the relationship between the jump height and the assessed force and power output of leg muscles.

  2. Control strategy of maximum vertical jumps: The preferred countermovement depth may not be fully optimized for jump height.

    Science.gov (United States)

    Mandic, Radivoj; Knezevic, Olivera M; Mirkov, Dragan M; Jaric, Slobodan

    2016-09-01

    The aim of the present study was to explore the control strategy of maximum countermovement jumps regarding the preferred countermovement depth preceding the concentric jump phase. Elite basketball players and physically active non-athletes were tested on the jumps performed with and without an arm swing, while the countermovement depth was varied within the interval of almost 30 cm around its preferred value. The results consistently revealed 5.1-11.2 cm smaller countermovement depth than the optimum one, but the same difference was more prominent in non-athletes. In addition, although the same differences revealed a marked effect on the recorded force and power output, they reduced jump height for only 0.1-1.2 cm. Therefore, the studied control strategy may not be based solely on the countermovement depth that maximizes jump height. In addition, the comparison of the two groups does not support the concept of a dual-task strategy based on the trade-off between maximizing jump height and minimizing the jumping quickness that should be more prominent in the athletes that routinely need to jump quickly. Further research could explore whether the observed phenomenon is based on other optimization principles, such as the minimization of effort and energy expenditure. Nevertheless, future routine testing procedures should take into account that the control strategy of maximum countermovement jumps is not fully based on maximizing the jump height, while the countermovement depth markedly confound the relationship between the jump height and the assessed force and power output of leg muscles.

  3. Measurement of the Depth of Maximum of Extensive Air Showers above 10^18 eV

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, J.; /Buenos Aires, CONICET; Abreu, P.; /Lisbon, IST; Aglietta, M.; /Turin U. /INFN, Turin; Ahn, E.J.; /Fermilab; Allard, D.; /APC, Paris; Allekotte, I.; /Centro Atomico Bariloche /Buenos Aires, CONICET; Allen, J.; /New York U.; Alvarez-Muniz, J.; /Santiago de Compostela U.; Ambrosio, M.; /Naples U.; Anchordoqui, L.; /Wisconsin U., Milwaukee; Andringa, S.; /Lisbon, IST /Boskovic Inst., Zagreb

    2010-02-01

    We describe the measurement of the depth of maximum, X{sub max}, of the longitudinal development of air showers induced by cosmic rays. Almost 4000 events above 10{sup 18} eV observed by the fluorescence detector of the Pierre Auger Observatory in coincidence with at least one surface detector station are selected for the analysis. The average shower maximum was found to evolve with energy at a rate of (106{sub -21}{sup +35}) g/cm{sup 2}/decade below 10{sup 18.24 {+-} 0.05}eV, and (24 {+-} 3) g/cm{sup 2}/decade above this energy. The measured shower-to-shower fluctuations decrease from about 55 to 26 g/cm{sup 2}. The interpretation of these results in terms of the cosmic ray mass composition is briefly discussed.

  4. Earthquake Rupture at Focal Depth, Part I: Structure and Rupture of the Pretorius Fault, TauTona Mine, South Africa

    Science.gov (United States)

    Heesakkers, V.; Murphy, S.; Reches, Z.

    2011-12-01

    We analyze the structure of the Archaean Pretorius fault in TauTona mine, South Africa, as well as the rupture-zone that recently reactivated it. The analysis is part of the Natural Earthquake Laboratory in South African Mines (NELSAM) project that utilizes the access to 3.6 km depth provided by the mining operations. The Pretorius fault is a ~10 km long, oblique-strike-slip fault with displacement of up to 200 m that crosscuts fine to very coarse grain quartzitic rocks in TauTona mine. We identify here three structural zones within the fault-zone: (1) an outer damage zone, ~100 m wide, of brittle deformation manifested by multiple, widely spaced fractures and faults with slip up to 3 m; (2) an inner damage zone, 25-30 m wide, with high density of anastomosing conjugate sets of fault segments and fractures, many of which carry cataclasite zones; and (3) a dominant segment, with a cataclasite zone up to 50 cm thick that accommodated most of the Archaean slip of the Pretorius fault, and is regarded as the `principal slip zone' (PSZ). This fault-zone structure indicates that during its Archaean activity, the Pretorius fault entered the mature fault stage in which many slip events were localized along a single, PSZ. The mining operations continuously induce earthquakes, including the 2004, M2.2 event that rejuvenated the Pretorius fault in the NELSAM project area. Our analysis of the M2.2 rupture-zone shows that (1) slip occurred exclusively along four, pre-existing large, quasi-planer segments of the ancient fault-zone; (2) the slipping segments contain brittle cataclasite zones up to 0.5 m thick; (3) these segments are not parallel to each other; (4) gouge zones, 1-5 mm thick, composed of white `rock-flour' formed almost exclusively along the cataclasite-host rock contacts of the slipping segments; (5) locally, new, fresh fractures branched from the slipping segments and propagated in mixed shear-tensile mode; (6) the maximum observed shear displacement is 25 mm in

  5. Similar mid-depth Atlantic water mass provenance during the Last Glacial Maximum and Heinrich Stadial 1

    Science.gov (United States)

    Howe, Jacob N. W.; Huang, Kuo-Fang; Oppo, Delia W.; Chiessi, Cristiano M.; Mulitza, Stefan; Blusztajn, Jurek; Piotrowski, Alexander M.

    2018-05-01

    The delivery of freshwater to the North Atlantic during Heinrich Stadial 1 (HS1) is thought to have fundamentally altered the operation of Atlantic meridional overturning circulation (AMOC). Although benthic foraminiferal carbon isotope records from the mid-depth Atlantic show a pronounced excursion to lower values during HS1, whether these shifts correspond to changes in water mass proportions, advection, or shifts in the carbon cycle remains unclear. Here we present new deglacial records of authigenic neodymium isotopes - a water mass tracer that is independent of the carbon cycle - from two cores in the mid-depth South Atlantic. We find no change in neodymium isotopic composition, and thus water mass proportions, between the Last Glacial Maximum (LGM) and HS1, despite large decreases in carbon isotope values at the onset of HS1 in the same cores. We suggest that the excursions of carbon isotopes to lower values were likely caused by the accumulation of respired organic matter due to slow overturning circulation, rather than to increased southern-sourced water, as typically assumed. The finding that there was little change in water mass provenance in the mid-depth South Atlantic between the LGM and HS1, despite decreased overturning, suggests that the rate of production of mid-depth southern-sourced water mass decreased in concert with decreased production of northern-sourced intermediate water at the onset of HS1. Consequently, we propose that even drastic changes in the strength of AMOC need not cause a significant change in South Atlantic mid-depth water mass proportions.

  6. Depth (Standard Deviation) Layer used to identify, delineate and classify moderate-depth benthic habitats around St. John, USVI

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Standard deviation of depth was calculated from the bathymetry surface for each cell using the ArcGIS Spatial Analyst Focal Statistics "STD" parameter. Standard...

  7. A simulation study of Linsley's approach to infer elongation rate and fluctuations of the EAS maximum depth from muon arrival time distributions

    International Nuclear Information System (INIS)

    Badea, A.F.; Brancus, I.M.; Rebel, H.; Haungs, A.; Oehlschlaeger, J.; Zazyan, M.

    1999-01-01

    The average depth of the maximum X m of the EAS (Extensive Air Shower) development depends on the energy E 0 and the mass of the primary particle, and its dependence from the energy is traditionally expressed by the so-called elongation rate D e defined as change in the average depth of the maximum per decade of E 0 i.e. D e = dX m /dlog 10 E 0 . Invoking the superposition model approximation i.e. assuming that a heavy primary (A) has the same shower elongation rate like a proton, but scaled with energies E 0 /A, one can write X m = X init + D e log 10 (E 0 /A). In 1977 an indirect approach studying D e has been suggested by Linsley. This approach can be applied to shower parameters which do not depend explicitly on the energy of the primary particle, but do depend on the depth of observation X and on the depth X m of shower maximum. The distribution of the EAS muon arrival times, measured at a certain observation level relatively to the arrival time of the shower core reflect the pathlength distribution of the muon travel from locus of production (near the axis) to the observation locus. The basic a priori assumption is that we can associate the mean value or median T of the time distribution to the height of the EAS maximum X m , and that we can express T = f(X,X m ). In order to derive from the energy variation of the arrival time quantities information about elongation rate, some knowledge is required about F i.e. F = - ∂ T/∂X m ) X /∂(T/∂X) X m , in addition to the variations with the depth of observation and the zenith-angle (θ) dependence, respectively. Thus ∂T/∂log 10 E 0 | X = - F·D e ·1/X v ·∂T/∂secθ| E 0 . In a similar way the fluctuations σ(X m ) of X m may be related to the fluctuations σ(T) of T i.e. σ(T) = - σ(X m )· F σ ·1/X v ·∂T/∂secθ| E 0 , with F σ being the corresponding scaling factor for the fluctuation of F. By simulations of the EAS development using the Monte Carlo code CORSIKA the energy and angle

  8. Assessment of the depth and extent of myometrial invasion in uterine adenomyosis using MRI

    International Nuclear Information System (INIS)

    Yi, Mi Gyung; Cho, Jae Ho; Chang, Jay Chun; Park, Bok Hwan

    2000-01-01

    To determine the detection rate of MRI in the diagnosis of adenomyosis and ascertain the accuracy of MRI in assessing the extent and depth of the myometrial invasion. By retrospective analysis of MR images of the pelvis in 65 pathologically proven cases of uterine adenomyosis, we investigated the detection rate and differences of in the detection rate when this was based on (a) the extent, and (b) the depth of myometrial invasion. The condition was classified as diffuse or focal according to the extent of invasion, and mild, moderate, or severe according to its depth. Pathologically, there were 35 cases of focal adenomyosis (53.8%), and 30 of diffuse adenomyosis (46.2%). Among patients with the focal variety of this condition, 12 cases were mild, 14 were mild, 14 were moderate, and nine were severe, while among those with the diffuse variety, two were mild, ten were moderate and 18 were severe. A total of 48 cases (73.8%) were detected on MR images; the detection rate of focal adenomyosis was 60.0% (21/35) and that of diffuse adenomyosis was 90.0% (27/30). The detection rates of mild, moderate, and severe adenomyosis were 42.9% (6/14), 79.2% (19/24), and 85.2% (23/27), respectively. Among the 48 cases detected on MR images, the pathologic and MR findings were consistent with regard to both the extent and depth of myometrial invasion in 26 (54.2%). For diffuse adenomyosis, the consistency rate was higher than for the focal variety (81.5%, 22/27; compared with 19%, 4/21). The extent of myometrial invasion was correctly evaluated in 32 cases (66.7%); the consistency rate for the diffuse form was higher than for the focal form (96.3%(26/27), compared with 28.6% (6/21)). In 42 cases (87.5%), the depth of invasion was correctly evaluated, though differences in this depth were not significant. MR imaging was a useful imaging modality in the diagnosis of uterine adenomyosis. With regard to the extent of myometrial invasion, the detection rate was higher among cases of the

  9. The design of LMJ focal spots for indirect drive experiments

    International Nuclear Information System (INIS)

    Le Garrec, B J; Sajer, J M

    2008-01-01

    LMJ is a 240 high power laser beam facility for achieving laser matter interaction experiments, high energy density science, including the demonstration of fusion ignition through Inertial Confinement. The Laser Integration Line (LIL) facility is currently a 4-beam prototype for LMJ. The intensity I 0 at the focal spot centre drives hydrodynamic and plasma instabilities and the intensity in the wings must be low to go through the laser entrance Hohlraum. A simple model has been developed to compute the LMJ focal spot. The model gives the intensity at the centre as a function of the focal spot area at 3% of the maximum

  10. Depth Perception In Remote Stereoscopic Viewing Systems

    Science.gov (United States)

    Diner, Daniel B.; Von Sydow, Marika

    1989-01-01

    Report describes theoretical and experimental studies of perception of depth by human operators through stereoscopic video systems. Purpose of such studies to optimize dual-camera configurations used to view workspaces of remote manipulators at distances of 1 to 3 m from cameras. According to analysis, static stereoscopic depth distortion decreased, without decreasing stereoscopitc depth resolution, by increasing camera-to-object and intercamera distances and camera focal length. Further predicts dynamic stereoscopic depth distortion reduced by rotating cameras around center of circle passing through point of convergence of viewing axes and first nodal points of two camera lenses.

  11. Interpretation of the depths of maximum of extensive air showers measured by the Pierre Auger Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Pedro; et al.

    2013-02-01

    To interpret the mean depth of cosmic ray air shower maximum and its dispersion, we parametrize those two observables as functions of the first two moments of the ln A distribution. We examine the goodness of this simple method through simulations of test mass distributions. The application of the parameterization to Pierre Auger Observatory data allows one to study the energy dependence of the mean ln A and of its variance under the assumption of selected hadronic interaction models. We discuss possible implications of these dependences in term of interaction models and astrophysical cosmic ray sources.

  12. Validation of calculated tissue maximum ratio obtained from measured percentage depth dose (PPD) data for high energy photon beam ( 6 MV and 15 MV)

    International Nuclear Information System (INIS)

    Osei, J.E.

    2014-07-01

    During external beam radiotherapy treatments, high doses are delivered to the cancerous cell. Accuracy and precision of dose delivery are primary requirements for effective and efficiency in treatment. This leads to the consideration of treatment parameters such as percentage depth dose (PDD), tissue air ratio (TAR) and tissue phantom ratio (TPR), which show the dose distribution in the patient. Nevertheless, tissue air ratio (TAR) for treatment time calculation, calls for the need to measure in-air-dose rate. For lower energies, measurement is not a problem but for higher energies, in-air measurement is not attainable due to the large build-up material required for the measurement. Tissue maximum ratio (TMR) is the quantity required to replace tissue air ratio (TAR) for high energy photon beam. It is known that tissue maximum ratio (TMR) is an important dosimetric function in radiotherapy treatment. As the calculation methods used to determine tissue maximum ratio (TMR) from percentage depth dose (PDD) were derived by considering the differences between TMR and PDD such as geometry and field size, where phantom scatter or peak scatter factors are used to correct dosimetric variation due to field size difference. The purpose of this study is to examine the accuracy of calculated tissue maximum ratio (TMR) data with measured TMR values for 6 MV and 15 MV photon beam at Sweden Ghana Medical Centre. With the help of the Blue motorize water phantom and the Omni pro-Accept software, Pdd values from which TMRs are calculated were measured at 100 cm source-to-surface distance (SSD) for various square field sizes from 5x5 cm to 40x40 cm and depth of 1.5 cm to 25 cm for 6 MV and 15 MV x-ray beam. With the same field sizes, depths and energies, the TMR values were measured. The validity of the calculated data was determined by making a comparison with values measured experimentally at some selected field sizes and depths. The results show that; the reference depth of maximum

  13. Implementation of focal zooming on the Nike KrF laser

    Energy Technology Data Exchange (ETDEWEB)

    Kehne, D. M.; Karasik, M.; Weaver, J. L.; Chan, Y.; Obenschain, S. P. [Plasma Physics Division, Naval Research Laboratory, Washington, DC 20375 (United States); Aglitsky, Y. [Science Applications International, McLean, Virginia 22150 (United States); Smyth, Z.; Lehmberg, R. H. [Research Support Instruments, Inc., Lanham, Maryland 20706 (United States); Terrell, S. [Commonwealth Technologies, Inc., Alexandria, Virginia 22315 (United States)

    2013-01-15

    In direct drive inertial confinement laser fusion, a pellet containing D-T fuel is imploded by ablation arising from absorption of laser energy at its outer surface. For optimal coupling, the focal spot of the laser would continuously decrease to match the reduction in the pellet's diameter, thereby minimizing wasted energy. A krypton-fluoride laser ({lambda}= 248 nm) that incorporates beam smoothing by induced spatial incoherence has the ability to produce a high quality focal profile whose diameter varies with time, a property known as focal zooming. A two-stage focal zoom has been demonstrated on the Nike laser at the Naval Research Laboratory. In the experiment, a 4.4 ns laser pulse was created in which the on-target focal spot diameter was 1.3 mm (full width at half maximum) for the first 2.4 ns and 0.28 mm for the final 2 ns. These two diameters appear in time-integrated focal plane equivalent images taken at several locations in the amplification chain. Eight of the zoomed output beams were overlapped on a 60 {mu}m thick planar polystyrene target. Time resolved images of self-emission from the rear of the target show the separate shocks launched by the two corresponding laser focal diameters.

  14. Implementation of focal zooming on the Nike KrF laser

    International Nuclear Information System (INIS)

    Kehne, D. M.; Karasik, M.; Weaver, J. L.; Chan, Y.; Obenschain, S. P.; Aglitsky, Y.; Smyth, Z.; Lehmberg, R. H.; Terrell, S.

    2013-01-01

    In direct drive inertial confinement laser fusion, a pellet containing D-T fuel is imploded by ablation arising from absorption of laser energy at its outer surface. For optimal coupling, the focal spot of the laser would continuously decrease to match the reduction in the pellet's diameter, thereby minimizing wasted energy. A krypton-fluoride laser (λ= 248 nm) that incorporates beam smoothing by induced spatial incoherence has the ability to produce a high quality focal profile whose diameter varies with time, a property known as focal zooming. A two-stage focal zoom has been demonstrated on the Nike laser at the Naval Research Laboratory. In the experiment, a 4.4 ns laser pulse was created in which the on-target focal spot diameter was 1.3 mm (full width at half maximum) for the first 2.4 ns and 0.28 mm for the final 2 ns. These two diameters appear in time-integrated focal plane equivalent images taken at several locations in the amplification chain. Eight of the zoomed output beams were overlapped on a 60 μm thick planar polystyrene target. Time resolved images of self-emission from the rear of the target show the separate shocks launched by the two corresponding laser focal diameters.

  15. Implementation of focal zooming on the Nike KrF laser

    Science.gov (United States)

    Kehne, D. M.; Karasik, M.; Aglitsky, Y.; Smyth, Z.; Terrell, S.; Weaver, J. L.; Chan, Y.; Lehmberg, R. H.; Obenschain, S. P.

    2013-01-01

    In direct drive inertial confinement laser fusion, a pellet containing D-T fuel is imploded by ablation arising from absorption of laser energy at its outer surface. For optimal coupling, the focal spot of the laser would continuously decrease to match the reduction in the pellet's diameter, thereby minimizing wasted energy. A krypton-fluoride laser (λ = 248 nm) that incorporates beam smoothing by induced spatial incoherence has the ability to produce a high quality focal profile whose diameter varies with time, a property known as focal zooming. A two-stage focal zoom has been demonstrated on the Nike laser at the Naval Research Laboratory. In the experiment, a 4.4 ns laser pulse was created in which the on-target focal spot diameter was 1.3 mm (full width at half maximum) for the first 2.4 ns and 0.28 mm for the final 2 ns. These two diameters appear in time-integrated focal plane equivalent images taken at several locations in the amplification chain. Eight of the zoomed output beams were overlapped on a 60 μm thick planar polystyrene target. Time resolved images of self-emission from the rear of the target show the separate shocks launched by the two corresponding laser focal diameters.

  16. Shaded-Mask Filtering for Extended Depth-of-Field Microscopy

    OpenAIRE

    Escobar García, Isabel María; Saavedra Tortosa, Genaro; Martínez Corral, Manuel; Calatayud, Arnau; Doblas Expósito, Ana Isabel

    2013-01-01

    This paper proposes a new spatial filtering approach for increasing the depth-of-field (DOF) of imaging systems, which is very useful for obtaining sharp images for a wide range of axial positions of the object. Many different techniques have been reported to increase the depth of field. However the main advantage in our method is its simplicity, since we propose the use of purely absorbing beam-shaping elements, which allows a high focal depth with a minimum modification of the optical archi...

  17. Extreme depth-of-field intraocular lenses

    Science.gov (United States)

    Baker, Kenneth M.

    1996-05-01

    A new technology brings the full aperture single vision pseudophakic eye's effective hyperfocal distance within the half-meter range. A modulated index IOL containing a subsurface zeroth order coherent microlenticular mosaic defined by an index gradient adds a normalizing function to the vergences or parallactic angles of incoming light rays subtended from field object points and redirects them, in the case of near-field images, to that of far-field images. Along with a scalar reduction of the IOL's linear focal range, this results in an extreme depth of field with a narrow depth of focus and avoids the focal split-up, halo, and inherent reduction in contrast of multifocal IOLs. A high microlenticular spatial frequency, which, while still retaining an anisotropic medium, results in a nearly total zeroth order propagation throughout the visible spectrum. The curved lens surfaces still provide most of the refractive power of the IOL, and the unique holographic fabrication technology is especially suitable not only for IOLs but also for contact lenses, artificial corneas, and miniature lens elements for cameras and other optical devices.

  18. Slab Geometry and Deformation in the Northern Nazca Subduction Zone Inferred From The Relocation and Focal mechanisms of Intermediate-Depth Earthquakes

    Science.gov (United States)

    Chang, Y.; Warren, L. M.; Prieto, G. A.

    2015-12-01

    In the northern Nazca subduction zone, the Nazca plate is subducting to the east beneath the South American Plate. At ~5.6ºN, the subducting plate has a 240-km east-west offset associated with a slab tear, called the Caldas tear, that separates the northern and southern segments. Our study seeks to better define the slab geometry and deformation in the southern segment, which has a high rate of intermediate-depth earthquakes (50-300 km) between 3.6ºN and 5.2ºN in the Cauca cluster. From Jan 2010 to Mar 2014, 228 intermediate-depth earthquakes in the Cauca cluster with local magnitude Ml 2.5-4.7 were recorded by 65 seismic stations of the Colombian National Seismic Network. We review and, if necessary, adjust the catalog P and S wave arrival picks. We use the travel times to relocate the earthquakes using a double difference relocation method. For earthquakes with Ml ≥3.8, we also use waveform modeling to compute moment tensors . The distribution of earthquake relocations shows an ~15-km-thick slab dipping to the SE. The dip angle increases from 20º at the northern edge of the cluster to 38º at the southern edge. Two concentrated groups of earthquakes extend ~40 km vertically above the general downdip trend, with a 20 km quiet gap between them at ~100 km depth. The earthquakes in the general downdip seismic zone have downdip compressional axes, while earthquakes close to the quiet gap and in the concentrated groups have an oblique component. The general decrease in slab dip angle to the north may be caused by mantle flow through the Caldas tear. The seismicity gap in the slab may be associated with an active deformation zone and the concentrated groups of earthquakes with oblique focal mechanisms could be due to a slab fold.

  19. Joint Source Location and Focal Mechanism Inversion: efficiency, accuracy and applications

    Science.gov (United States)

    Liang, C.; Yu, Y.

    2017-12-01

    The analysis of induced seismicity has become a common practice to evaluate the results of hydraulic fracturing treatment. Liang et al (2016) proposed a joint Source Scanning Algorithms (jSSA for short) to obtain microseismic events and focal mechanisms simultaneously. The jSSA is superior over traditional SSA in many aspects, but the computation cost is too significant to be applied in real time monitoring. In this study, we have developed several scanning schemas to reduce computation time. A multi-stage scanning schema is proved to be able to improve the efficiency significantly while also retain its accuracy. A series of tests have been carried out by using both real field data and synthetic data to evaluate the accuracy of the method and its dependence on noise level, source depths, focal mechanisms and other factors. The surface-based arrays have better constraints on horizontal location errors (0.5). For sources with varying rakes, dips, strikes and depths, the errors are mostly controlled by the partition of positive and negative polarities in different quadrants. More evenly partitioned polarities in different quadrants yield better results in both locations and focal mechanisms. Nevertheless, even with bad resolutions for some FMs, the optimized jSSA method can still improve location accuracies significantly. Based on much more densely distributed events and focal mechanisms, a gridded stress inversion is conducted to get a evenly distributed stress field. The full potential of the jSSA has yet to be explored in different directions, especially in earthquake seismology as seismic array becoming incleasingly dense.

  20. TRIM15 is a focal adhesion protein that regulates focal adhesion disassembly

    Science.gov (United States)

    Uchil, Pradeep D.; Pawliczek, Tobias; Reynolds, Tracy D.; Ding, Siyuan; Hinz, Angelika; Munro, James B.; Huang, Fang; Floyd, Robert W.; Yang, Haitao; Hamilton, William L.; Bewersdorf, Joerg; Xiong, Yong; Calderwood, David A.; Mothes, Walther

    2014-01-01

    ABSTRACT Focal adhesions are macromolecular complexes that connect the actin cytoskeleton to the extracellular matrix. Dynamic turnover of focal adhesions is crucial for cell migration. Paxillin is a multi-adaptor protein that plays an important role in regulating focal adhesion dynamics. Here, we identify TRIM15, a member of the tripartite motif protein family, as a paxillin-interacting factor and a component of focal adhesions. TRIM15 localizes to focal contacts in a myosin-II-independent manner by an interaction between its coiled-coil domain and the LD2 motif of paxillin. Unlike other focal adhesion proteins, TRIM15 is a stable focal adhesion component with restricted mobility due to its ability to form oligomers. TRIM15-depleted cells display impaired cell migration and reduced focal adhesion disassembly rates, in addition to enlarged focal adhesions. Thus, our studies demonstrate a cellular function for TRIM15 as a regulatory component of focal adhesion turnover and cell migration. PMID:25015296

  1. A video-rate range sensor based on depth from defocus

    OpenAIRE

    Ghita, Ovidiu; Whelan, Paul F.

    2001-01-01

    Recovering the depth information derived from dynamic scenes implies real-time range estimation. This paper addresses the implementation of a bifocal range sensor which estimates the depth by measuring the relative blurring between two images captured with different focal settings. To recover the depth accurately even in cases when the scene is textureless, one possible solution is to project a structured light on the scene. As a consequence, in the scene's spectrum a spatial frequency derive...

  2. Earthquake rupture at focal depth, part II: mechanics of the 2004 M2.2 earthquake along the Pretorius Fault, TauTona Mine, South Africa

    Science.gov (United States)

    Heesakkers, V.; Murphy, S.; Lockner, D.A.; Reches, Z.

    2011-01-01

    We analyze here the rupture mechanics of the 2004, M2.2 earthquake based on our observations and measurements at focal depth (Part I). This event ruptured the Archean Pretorius fault that has been inactive for at least 2 Ga, and was reactivated due to mining operations down to a depth of 3.6 km depth. Thus, it was expected that the Pretorius fault zone will fail similarly to an intact rock body independently of its ancient healed structure. Our analysis reveals a few puzzling features of the M2.2 rupture-zone: (1) the earthquake ruptured four, non-parallel, cataclasite bearing segments of the ancient Pretorius fault-zone; (2) slip occurred almost exclusively along the cataclasite-host rock contacts of the slipping segments; (3) the local in-situ stress field is not favorable to slip along any of these four segments; and (4) the Archean cataclasite is pervasively sintered and cemented to become brittle and strong. To resolve these observations, we conducted rock mechanics experiments on the fault-rocks and host-rocks and found a strong mechanical contrast between the quartzitic cataclasite zones, with elastic-brittle rheology, and the host quartzites, with damage, elastic–plastic rheology. The finite-element modeling of a heterogeneous fault-zone with the measured mechanical contrast indicates that the slip is likely to reactivate the ancient cataclasite-bearing segments, as observed, due to the strong mechanical contrast between the cataclasite and the host quartzitic rock.

  3. Visual Discomfort and Depth-of-Field

    Directory of Open Access Journals (Sweden)

    Louise O'Hare

    2013-05-01

    Full Text Available Visual discomfort has been reported for certain visual stimuli and under particular viewing conditions, such as stereoscopic viewing. In stereoscopic viewing, visual discomfort can be caused by a conflict between accommodation and convergence cues that may specify different distances in depth. Earlier research has shown that depth-of-field, which is the distance range in depth in the scene that is perceived to be sharp, influences both the perception of egocentric distance to the focal plane, and the distance range in depth between objects in the scene. Because depth-of-field may also be in conflict with convergence and the accommodative state of the eyes, we raised the question of whether depth-of-field affects discomfort when viewing stereoscopic photographs. The first experiment assessed whether discomfort increases when depth-of-field is in conflict with coherent accommodation–convergence cues to distance in depth. The second experiment assessed whether depth-of-field influences discomfort from a pre-existing accommodation–convergence conflict. Results showed no effect of depth-of-field on visual discomfort. These results suggest therefore that depth-of-field can be used as a cue to depth without inducing discomfort in the viewer, even when cue conflicts are large.

  4. Depth-resolution imaging of crystalline nanoclusters attached on and embedded in amorphous films using aberration-corrected TEM

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, Jun, E-mail: yamasaki@uhvem.osaka-u.ac.jp [Research Center for Ultra-High Voltage Electron Microscopy, Osaka University, 7-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); EcoTopia Science Institute, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Mori, Masayuki [Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Hirata, Akihiko [Advanced Institute for Materials Research, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Hirotsu, Yoshihiko [Institute of Scientific and Industrial Research, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Tanaka, Nobuo [EcoTopia Science Institute, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2015-04-15

    For observations of crystalline nanoclusters, the features and capabilities of depth-resolution imaging by aberration-corrected transmission electron microscopy (TEM) were investigated using image simulations and experiments for two types of samples. The first sample was gold clusters attached on an amorphous carbon film. The experimental through-focal series indicated that the focal plane for the cluster was shifted 3 nm from that for the supporting film. This difference is due to the depth-resolution imaging of the cluster and film, the mid-planes of which are separated by 3 nm along the depth direction (the electron incident direction). On the basis of this information, the three-dimensional configuration of the sample, such as the film thickness of 2 nm, was successfully illustrated. The second sample was a Zr{sub 66.7}Ni{sub 33.3} metallic glass including a medium-range-order (MRO) structure, which was approximately considered to be a crystalline cluster with a diameter of 1.6 nm. In the experimental through-focal series, the lattice fringe of the MRO cluster was visible at limited focal conditions. Image simulations reproduced well the focal conditions and also indicated a structural condition for the visualization that the embedded cluster must be apart from the mid-plane of the matrix film. Similar to the case of the first sample, this result can be explained by the idea that the “effective focal planes” for the film and cluster are at different heights. This type of depth-resolution phase contrast imaging is possible only in aberration-corrected TEM and when the sample has a simple structure and is sufficiently thin for the kinematical scattering approximation. - Highlights: • Depth-resolution imaging by aberration-corrected TEM was demonstrated. • Thickness of a carbon film supporting gold nano-crystals was successfully estimated. • A crystalline nanocluster embedded in an amorphous matrix was successfully observed. • It was clarified that

  5. Focal myositis

    International Nuclear Information System (INIS)

    Kransdorf, M.J.; Temple, H.T.; Sweet, D.E.

    1998-01-01

    Focal myositis is a pseudotumor of soft tissue that typically occurs in the deep soft tissue of the extremities, and is a relatively rare lesion. There is a wide clinical spectrum, with approximately one-third of patients with focal myositis subsequently developing polymyositis, and clinical symptoms of generalized weakness, fever, myalgia, and weight loss, with elevation of creatine phosphokinase. We report the case of a patient with focal myositis who subsequently developed myositis ossificans-like features. (orig.)

  6. Influence of spatial and temporal spot distribution on the ocular surface quality and maximum ablation depth after photoablation with a 1050 Hz excimer laser system.

    Science.gov (United States)

    Mrochen, Michael; Schelling, Urs; Wuellner, Christian; Donitzky, Christof

    2009-02-01

    To investigate the effect of temporal and spatial distributions of laser spots (scan sequences) on the corneal surface quality after ablation and the maximum ablation of a given refractive correction after photoablation with a high-repetition-rate scanning-spot laser. IROC AG, Zurich, Switzerland, and WaveLight AG, Erlangen, Germany. Bovine corneas and poly(methyl methacrylate) (PMMA) plates were photoablated using a 1050 Hz excimer laser prototype for corneal laser surgery. Four temporal and spatial spot distributions (scan sequences) with different temporal overlapping factors were created for 3 myopic, 3 hyperopic, and 3 phototherapeutic keratectomy ablation profiles. Surface quality and maximum ablation depth were measured using a surface profiling system. The surface quality factor increased (rough surfaces) as the amount of temporal overlapping in the scan sequence and the amount of correction increased. The rise in surface quality factor was less for bovine corneas than for PMMA. The scan sequence might cause systematic substructures at the surface of the ablated material depending on the overlapping factor. The maximum ablation varied within the scan sequence. The temporal and spatial distribution of the laser spots (scan sequence) during a corneal laser procedure affected the surface quality and maximum ablation depth of the ablation profile. Corneal laser surgery could theoretically benefit from smaller spot sizes and higher repetition rates. The temporal and spatial spot distributions are relevant to achieving these aims.

  7. Focal myositis

    Energy Technology Data Exchange (ETDEWEB)

    Kransdorf, M.J. [Saint Mary`s Hospital, Richmond, VA (United States). Dept. of Radiol.]|[Department of Radiologic Pathology, Armed Forces Institute of Pathology, Washington, DC (United States); Temple, H.T. [Department of Orthopedic Surgery, University of Virginia Health Sciences Center, Charlottesville, Virginia (United States)]|[Department of Orthopedic Pathology, Armed Forces Institute of Pathology, Washington, DC (United States); Sweet, D.E. [Department of Orthopedic Pathology, Armed Forces Institute of Pathology, Washington, DC (United States)

    1998-05-01

    Focal myositis is a pseudotumor of soft tissue that typically occurs in the deep soft tissue of the extremities, and is a relatively rare lesion. There is a wide clinical spectrum, with approximately one-third of patients with focal myositis subsequently developing polymyositis, and clinical symptoms of generalized weakness, fever, myalgia, and weight loss, with elevation of creatine phosphokinase. We report the case of a patient with focal myositis who subsequently developed myositis ossificans-like features. (orig.) With 3 figs., 25 refs.

  8. Adjustable focus laser sheet module for generating constant maximum width sheets for use in optical flow diagnostics

    International Nuclear Information System (INIS)

    Hult, J; Mayer, S

    2011-01-01

    A general design of a laser light sheet module with adjustable focus is presented, where the maximum sheet width is preserved over a fixed region. In contrast, conventional focusing designs are associated with a variation in maximum sheet width with focal position. A four lens design is proposed here, where the first three lenses are employed for focusing, and the last for sheet expansion. A maximum sheet width of 1100 µm was maintained over a 50 mm long distance, for focal distances ranging from 75 to 500 mm, when a 532 nm laser beam with a beam quality factor M 2 = 29 was used for illumination

  9. Breaking the Crowther limit: Combining depth-sectioning and tilt tomography for high-resolution, wide-field 3D reconstructions

    International Nuclear Information System (INIS)

    Hovden, Robert; Ercius, Peter; Jiang, Yi; Wang, Deli; Yu, Yingchao; Abruña, Héctor D.; Elser, Veit; Muller, David A.

    2014-01-01

    To date, high-resolution ( 6 nm) to appear blurred or missing. Here we demonstrate a three-dimensional imaging method that overcomes both these limits by combining through-focal depth sectioning and traditional tilt-series tomography to reconstruct extended objects, with high-resolution, in all three dimensions. The large convergence angle in aberration corrected instruments now becomes a benefit and not a hindrance to higher quality reconstructions. A through-focal reconstruction over a 390 nm 3D carbon support containing over 100 dealloyed and nanoporous PtCu catalyst particles revealed with sub-nanometer detail the extensive and connected interior pore structure that is created by the dealloying instability. - Highlights: • Develop tomography technique for high-resolution and large field of view. • We combine depth sectioning with traditional tilt tomography. • Through-focal tomography reduces tilts and improves resolution. • Through-focal tomography overcomes the fundamental Crowther limit. • Aberration-corrected becomes a benefit and not a hindrance for tomography

  10. Determination Hypocentre and Focal Mechanism Earthquake of Oct 31, 2016 in Bone, South Sulawesi

    Science.gov (United States)

    Altin Massinai, Muhammad; Fawzy Ismullah M, Muhammad

    2018-03-01

    Indonesian Meteorology, Climatology and Geophysics Agency (BMKG) recorded an earthquake with M4.6 on at October 31, 2016 at Bone District, around 80 Km northeast form Makassar, South Sulawesi. The earthquake occurred 18:18:14 local time in 4.7°S, 120°E with depth 10 Km. Seismicity around location predicted caused by activity Walennae fault. We reprocessed earthquake data to determine precise hypocentre location and focal mechanism. The P- and S-wave arrival time got from BMKG used as input HYPOELLIPSE code to determine hypocentre. The results showed that the earthquake occurred 10:18:14.46 UTC in 4.638°S, 119.966°E with depth 24.76 Km. The hypocentre resolved 10 Km fix depth and had lower travel time residual than BMKG result. Focal mechanism determination used Azmtak code based on the first arrival polarity at earthquake waveform manually picked. The result showed a reverse mechanism with strike direction 38°, dip 44°, rake angle 134° on fault plane I and strike direction 164°, dip 60°, rake angle 56° on fault plane II. So, the earthquake which may be related to a reverse East Walennae Fault.

  11. Nonlinear focal shift beyond the geometrical focus in moderately focused acoustic beams.

    Science.gov (United States)

    Camarena, Francisco; Adrián-Martínez, Silvia; Jiménez, Noé; Sánchez-Morcillo, Víctor

    2013-08-01

    The phenomenon of the displacement of the position along the axis of the pressure, intensity, and radiation force maxima of focused acoustic beams under increasing driving voltages (nonlinear focal shift) is studied for the case of a moderately focused beam. The theoretical and experimental results show the existence of this shift along the axis when the initial pressure in the transducer increases until the acoustic field reaches the fully developed nonlinear regime of propagation. Experimental data show that at high amplitudes and for moderate focusing, the position of the on-axis pressure maximum and radiation force maximum can surpass the geometrical focal length. On the contrary, the on-axis pressure minimum approaches the transducer under increasing driving voltages, increasing the distance between the positive and negative peak pressure in the beam. These results are in agreement with numerical KZK model predictions and the existed data of other authors and can be explained according to the effect of self-refraction characteristic of the nonlinear regime of propagation.

  12. Focal retinal phlebitis.

    Science.gov (United States)

    Hoang, Quan V; Freund, K Bailey; Klancnik, James M; Sorenson, John A; Cunningham, Emmett T; Yannuzzi, Lawrence A

    2012-01-01

    To report three cases of solitary, focal retinal phlebitis. An observational case series. Three eyes in three patients were noted to have unilateral decreased vision, macular edema, and a focal retinal phlebitis, which was not at an arteriovenous crossing. All three patients developed a branch retinal vein occlusion at the site of inflammation. These patients had no other evidence of intraocular inflammation, including vitritis, retinitis, retinal vasculitis, or choroiditis, nor was there any systemic disorder associated with inflammation, infection, or coagulation identified. Focal retinal phlebitis appears to be an uncommon and unique entity that produces macular edema and ultimately branch retinal vein occlusion. In our patients, the focal phlebitis and venous occlusion did not occur at an arteriovenous crossing, which is the typical site for branch retinal venous occlusive disease. This suggests that our cases represent a distinct clinical entity, which starts with a focal abnormality in the wall of a retinal venule, resulting in surrounding exudation and, ultimately, ends with branch retinal vein occlusion.

  13. Focal myositis

    International Nuclear Information System (INIS)

    Galloway, H.R.; Dahlstrom, J.E.; Bennett, G.M.

    2001-01-01

    Focal myositis is a rare, benign focal inflammation of muscle. The lesion often presents as a mass that may be mistaken for a soft tissue sarcoma. This report describes the MRI and histopathological features of a case and illustrates how the diagnosis may be suspected on the basis of the MR findings. Copyright (2001) Blackwell Science Pty Ltd

  14. Focal pancreatic enlargement: differentiation between pancreatic adenocarcinoma and focal pancreatitis on CT and ERCP

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Kim, Ki Whang; Lee, Jong Tae; Kim, Hee Soo; Yoo, Hyung Sik; Yu, Jeong Sik; Yoon, Sang Wook

    1995-01-01

    To differentiate the pancreatic adenocarcinoma from focal pancreatitis on CT and ERCP in cases of focal pancreatic enlargement. We analysed CT findings of 66 patients of pancreatic adenocarcinoma (n = 45) or focal pancreatitis (n = 21) with respect to size, density, calcification, pancreatic or biliary duct dilatation, fat plane obliteration around the vessels, direction of retroperitoneal extension, lymphadenopathy, pseudocyst formation and atrophy of pancreas. ERCP available in 48 patients were analysed in respect to morphologic appearance of CBD and pancreatic duct, and distance between the two ducts. The patients in focal pancreatitis were younger with more common history of alcohol drinking. There was no statistical difference in calcifications of the mass (18% in the adenocarcinoma, 33% in the focal pancreatitis), but a tendency of denser, larger number of calcifications was noted in focal pancreatitis. The finding of fat plane obliteration around the vessels were more common in pancreatic adenocarcinoma, and fascial thickenings were more prominent in focal pancreatitis, although not statistically significant. On ERCP, there were no differential points of CBD, pancreatic duct morphology, but distance between the two ducts at the lesion center was more wider in focal pancreatitis. Differentiating focal pancreatitis from pancreatic adenocarcinoma is difficult. However, we should consider the possibility of focal pancreatitis in cases of patients with young age, having alcoholic history in association with CT findings of large numbers of and dense calcifications, and ERCP findings of prominent separation of two duct at the lesion center

  15. METHOD FOR DETERMINATION OF FOCAL PLANE LOCATION OF FOCUSING COMPONENTS

    Directory of Open Access Journals (Sweden)

    A. I. Ivashko

    2017-01-01

    Full Text Available Mass-production of different laser systems often requires utilization of the focal spot size method for determination of output laser beam spatial characteristics. The main challenge of this method is high accuracy maintenance of a CCD camera beam profiler in the collecting lens focal plane. The aim of our work is development of new method for placing of photodetector array in the collecting lens focal plane with high accuracy.Proposed technique is based on focusing of several parallel laser beams. Determination of the focal plane position requires only longitudinal translation of the CCD-camera to find a point of laser beams intersection. Continuous-wave (CW diode-pumped laser emitting in the spectral region near 1μm was created to satisfy the requirements of the developed technique. Designed microchip laser generates two stigmatic Gaussian beams with automatically parallel beam axes due to independent pumping of different areas of the one microchip crystal having the same cavity mirrors.It was theoretically demonstrated that developed method provides possibility of the lenses focal plane determination with 1 % accuracy. The microchip laser generates two parallel Gaussian beams with divergence of about 10 mrad. Laser output power can be varied in the range of 0.1–1.5 W by changing the pumping laser diode electrical current. The distance between two beam axes can be changed in the range of 0.5–5.0 mm.We have proposed method for determination of positive lens focal plane location by using of CCDcamera and two laser beams with parallel axes without utilization of additional optical devices. We have developed CW longitudinally diode pumped microchip laser emitting in the 1-μm spectral region that can be used in the measuring instrument that doesn’t require precision mechanical components for determination of focal plane location with 1 % accuracy. The overall dimensions of laser head was 70 × 40 × 40 mm3 and maximum power consumption was

  16. Transparent meta-analysis: does aging spare prospective memory with focal vs. non-focal cues?

    Directory of Open Access Journals (Sweden)

    Bob Uttl

    Full Text Available BACKGROUND: Prospective memory (ProM is the ability to become aware of a previously-formed plan at the right time and place. For over twenty years, researchers have been debating whether prospective memory declines with aging or whether it is spared by aging and, most recently, whether aging spares prospective memory with focal vs. non-focal cues. Two recent meta-analyses examining these claims did not include all relevant studies and ignored prevalent ceiling effects, age confounds, and did not distinguish between prospective memory subdomains (e.g., ProM proper, vigilance, habitual ProM (see Uttl, 2008, PLoS ONE. The present meta-analysis focuses on the following questions: Does prospective memory decline with aging? Does prospective memory with focal vs. non-focal cues decline with aging? Does the size of age-related declines with focal vs. non-focal cues vary across ProM subdomains? And are age-related declines in ProM smaller than age-related declines in retrospective memory? METHODS AND FINDINGS: A meta-analysis of event-cued ProM using data visualization and modeling, robust count methods, and conventional meta-analysis techniques revealed that first, the size of age-related declines in ProM with both focal and non-focal cues are large. Second, age-related declines in ProM with focal cues are larger in ProM proper and smaller in vigilance. Third, age-related declines in ProM proper with focal cues are as large as age-related declines in recall measures of retrospective memory. CONCLUSIONS: The results are consistent with Craik's (1983 proposal that age-related declines on ProM tasks are generally large, support the distinction between ProM proper vs. vigilance, and directly contradict widespread claims that ProM, with or without focal cues, is spared by aging.

  17. Stress regimes in the northwest of Iran from stress inversion of earthquake focal mechanisms

    Science.gov (United States)

    Afra, Mahsa; Moradi, Ali; Pakzad, Mehrdad

    2017-11-01

    Northwestern Iran is one of the seismically active regions with a high seismic risk in the world. This area is a part of the complex tectonic system due to the interaction between Arabia, Anatolia and Eurasia. The purpose of this study is to deduce the stress regimes in the northwestern Iran and surrounding regions from stress inversion of earthquake focal mechanisms. We compile 92 focal mechanisms data from the Global CMT catalogue and other sources and also determine the focal mechanisms of 14 earthquakes applying the moment tensor inversion. We divide the studied region into 9 zones using similarity of the horizontal GPS velocities and existing focal mechanisms. We implement two stress inversion methods, Multiple Inverse Method and Iterative Joint Inversion Method, which provide comparable results in terms of orientations of maximum horizontal stress axes SHmax. The similar results of the two methods should make us more confident about the interpretations. We consider zones of exclusion surrounding all the earthquakes according to independent focal mechanisms hypothesis. The hypothesis says that the inversion should involve events that are far enough from each other in order that any previous event doesn't affect the stress field near the earthquake under consideration. Accordingly we deal with the matter by considering zones of exclusion around all the events. The result of exclusion is only significant for eastern Anatolia. The stress regime in this region changes from oblique to strike slip faulting because of the exclusion. In eastern Anatolia, the direction of maximum horizontal stress is nearly north-south. The direction alters to east-west in Talesh region. Errors of σ1 are lower in all zones comparing with errors of σ2 and σ3 and there is a trade-off between data resolution and covariance of the model. The results substantiate the strike-slip and thrust faulting stress regimes in the northwest of Iran.

  18. Breaking the Crowther limit: Combining depth-sectioning and tilt tomography for high-resolution, wide-field 3D reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Hovden, Robert, E-mail: rmh244@cornell.edu [School of Applied and Engineering Physics and Kavli Institute at Cornell for Nanoscale Science, Cornell University, Ithaca, NY 14853 (United States); Ercius, Peter [National Center for Electron Microscopy, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Jiang, Yi [Department of Physics, Cornell University, Ithaca, NY 14853 (United States); Wang, Deli; Yu, Yingchao; Abruña, Héctor D. [Department of Chemistry and Chemical Biology, Cornell University, Ithaca, NY 14853 (United States); Elser, Veit [Department of Physics, Cornell University, Ithaca, NY 14853 (United States); Muller, David A. [School of Applied and Engineering Physics and Kavli Institute at Cornell for Nanoscale Science, Cornell University, Ithaca, NY 14853 (United States)

    2014-05-01

    To date, high-resolution (<1 nm) imaging of extended objects in three-dimensions (3D) has not been possible. A restriction known as the Crowther criterion forces a tradeoff between object size and resolution for 3D reconstructions by tomography. Further, the sub-Angstrom resolution of aberration-corrected electron microscopes is accompanied by a greatly diminished depth of field, causing regions of larger specimens (>6 nm) to appear blurred or missing. Here we demonstrate a three-dimensional imaging method that overcomes both these limits by combining through-focal depth sectioning and traditional tilt-series tomography to reconstruct extended objects, with high-resolution, in all three dimensions. The large convergence angle in aberration corrected instruments now becomes a benefit and not a hindrance to higher quality reconstructions. A through-focal reconstruction over a 390 nm 3D carbon support containing over 100 dealloyed and nanoporous PtCu catalyst particles revealed with sub-nanometer detail the extensive and connected interior pore structure that is created by the dealloying instability. - Highlights: • Develop tomography technique for high-resolution and large field of view. • We combine depth sectioning with traditional tilt tomography. • Through-focal tomography reduces tilts and improves resolution. • Through-focal tomography overcomes the fundamental Crowther limit. • Aberration-corrected becomes a benefit and not a hindrance for tomography.

  19. Focal thyroid inferno” on color Doppler ultrasonography: A specific feature of focal Hashimoto's thyroiditis

    International Nuclear Information System (INIS)

    Fu, Xianshui; Guo, Limei; Zhang, Huabin; Ran, Weiqiang; Fu, Peng; Li, Zhiqiang; Chen, Wen; Jiang, Ling; Wang, Jinrui; Jia, Jianwen

    2012-01-01

    Purpose: To evaluate color-Doppler features predictive of focal Hashimoto's thyroiditis. Materials and methods: A total of 521 patients with 561 thyroid nodules that underwent surgeries or gun biopsies were included in this study. These nodules were divided into three groups: focal Hashimoto's thyroiditis (104 nodules in 101 patients), benignity other than focal Hashimoto's thyroiditis (73 nodules in 70 patients), and malignancy (358 nodules in 350 patients). On color Doppler sonography, four vascularity types were determined as: hypovascularity, marked internal flow, marked peripheral flow and focal thyroid inferno. The χ 2 test was performed to seek the potential vascularity type with the predictive ability of certain thyroid pathology. Furthermore, the gray-scale features of each nodule were also studied. Results: The vascularity type I (hypovascularity) was more often seen in focal Hashimoto's thyroiditis than other benignity and malignancy (46% vs. 20.5% and 19%). While the type II (marked internal flow) showed the opposite tendency (26.9% [focal Hashimoto's thyroiditis] vs. 45.2% [other benignity] and 52.8% [malignancy]). However, type III (marked peripheral flow) was unable to predict any thyroid pathology. Importantly, type IV (focal thyroid inferno) was exclusive to focal Hashimoto's thyroiditis. All 8 type IV nodules appeared to be solid, hypoechoic, and well-defined. Using “focal thyroid inferno” as an indicator of FHT, the diagnostic sensitivity and specificity were 7.7% and 100% respectively. Conclusions: The vascularity type of “focal thyroid inferno” is specific for focal Hashimoto thyroiditis. Recognition of this particular feature may avoid unnecessary interventional procedures for some solid hypoechoic thyroid nodules suspicious of malignancy.

  20. Quality parameters analysis of optical imaging systems with enhanced focal depth using the Wigner distribution function

    Science.gov (United States)

    Zalvidea; Colautti; Sicre

    2000-05-01

    An analysis of the Strehl ratio and the optical transfer function as imaging quality parameters of optical elements with enhanced focal length is carried out by employing the Wigner distribution function. To this end, we use four different pupil functions: a full circular aperture, a hyper-Gaussian aperture, a quartic phase plate, and a logarithmic phase mask. A comparison is performed between the quality parameters and test images formed by these pupil functions at different defocus distances.

  1. WE-E-BRE-04: Dual Focal Spot Dose Painting for Precision Preclinical Radiobiological Investigations

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, J; Lindsay, P [Princess Margaret Cancer Centre, Toronto (Canada); University of Toronto, Toronto (Canada); Jaffray, D [Princess Margaret Cancer Centre, Toronto (Canada); The Techna Institute for the Advancement of Technology for Health, Toronto (Canada)

    2014-06-15

    Purpose: Recent progress in small animal radiotherapy systems has provided the foundation for delivering the heterogeneous, millimeter scale dose distributions demanded by preclinical radiobiology investigations. Despite advances in preclinical dose planning, delivery of highly heterogeneous dose distributions is constrained by the fixed collimation systems and large x-ray focal spot common in small animal radiotherapy systems. This work proposes a dual focal spot dose optimization and delivery method with a large x-ray focal spot used to deliver homogeneous dose regions and a small focal spot to paint spatially heterogeneous dose regions. Methods: Two-dimensional dose kernels were measured for a 1 mm circular collimator with radiochromic film at 10 mm depth in a solid water phantom for the small and large x-ray focal spots on a recently developed small animal microirradiator. These kernels were used in an optimization framework which segmented a desired dose distribution into low- and high-spatial frequency regions for delivery by the large and small focal spot, respectively. For each region, the method determined an optimal set of stage positions and beam-on times. The method was demonstrated by optimizing a bullseye pattern consisting of 0.75 mm radius circular target and 0.5 and 1.0 mm wide rings alternating between 0 and 2 Gy. Results: Compared to a large focal spot technique, the dual focal spot technique improved the optimized dose distribution: 69.2% of the optimized dose was within 0.5 Gy of the intended dose for the large focal spot, compared to 80.6% for the dual focal spot method. The dual focal spot design required 14.0 minutes of optimization, and will require 178.3 minutes for automated delivery. Conclusion: The dual focal spot optimization and delivery framework is a novel option for delivering conformal and heterogeneous dose distributions at the preclinical level and provides a new experimental option for unique radiobiological investigations

  2. WE-E-BRE-04: Dual Focal Spot Dose Painting for Precision Preclinical Radiobiological Investigations

    International Nuclear Information System (INIS)

    Stewart, J; Lindsay, P; Jaffray, D

    2014-01-01

    Purpose: Recent progress in small animal radiotherapy systems has provided the foundation for delivering the heterogeneous, millimeter scale dose distributions demanded by preclinical radiobiology investigations. Despite advances in preclinical dose planning, delivery of highly heterogeneous dose distributions is constrained by the fixed collimation systems and large x-ray focal spot common in small animal radiotherapy systems. This work proposes a dual focal spot dose optimization and delivery method with a large x-ray focal spot used to deliver homogeneous dose regions and a small focal spot to paint spatially heterogeneous dose regions. Methods: Two-dimensional dose kernels were measured for a 1 mm circular collimator with radiochromic film at 10 mm depth in a solid water phantom for the small and large x-ray focal spots on a recently developed small animal microirradiator. These kernels were used in an optimization framework which segmented a desired dose distribution into low- and high-spatial frequency regions for delivery by the large and small focal spot, respectively. For each region, the method determined an optimal set of stage positions and beam-on times. The method was demonstrated by optimizing a bullseye pattern consisting of 0.75 mm radius circular target and 0.5 and 1.0 mm wide rings alternating between 0 and 2 Gy. Results: Compared to a large focal spot technique, the dual focal spot technique improved the optimized dose distribution: 69.2% of the optimized dose was within 0.5 Gy of the intended dose for the large focal spot, compared to 80.6% for the dual focal spot method. The dual focal spot design required 14.0 minutes of optimization, and will require 178.3 minutes for automated delivery. Conclusion: The dual focal spot optimization and delivery framework is a novel option for delivering conformal and heterogeneous dose distributions at the preclinical level and provides a new experimental option for unique radiobiological investigations

  3. Solar Maximum Mission Experiment - Ultraviolet Spectroscopy and Polarimetry on the Solar Maximum Mission

    Science.gov (United States)

    Tandberg-Hanssen, E.; Cheng, C. C.; Woodgate, B. E.; Brandt, J. C.; Chapman, R. D.; Athay, R. G.; Beckers, J. M.; Bruner, E. C.; Gurman, J. B.; Hyder, C. L.

    1981-01-01

    The Ultraviolet Spectrometer and Polarimeter on the Solar Maximum Mission spacecraft is described. It is pointed out that the instrument, which operates in the wavelength range 1150-3600 A, has a spatial resolution of 2-3 arcsec and a spectral resolution of 0.02 A FWHM in second order. A Gregorian telescope, with a focal length of 1.8 m, feeds a 1 m Ebert-Fastie spectrometer. A polarimeter comprising rotating Mg F2 waveplates can be inserted behind the spectrometer entrance slit; it permits all four Stokes parameters to be determined. Among the observing modes are rasters, spectral scans, velocity measurements, and polarimetry. Examples of initial observations made since launch are presented.

  4. Radionuclide imaging with coded apertures and three-dimensional image reconstruction from focal-plane tomography

    International Nuclear Information System (INIS)

    Chang, L.T.

    1976-05-01

    Two techniques for radionuclide imaging and reconstruction have been studied;; both are used for improvement of depth resolution. The first technique is called coded aperture imaging, which is a technique of tomographic imaging. The second technique is a special 3-D image reconstruction method which is introduced as an improvement to the so called focal-plane tomography

  5. Focal CT abnormality and epileptogenic focus

    International Nuclear Information System (INIS)

    Yagi, Kazuichi; Mihara, Tadahiro; Tottori, Takayasu; Matsuda, Kazumi; Watanabe, Yutaka; Seino, Masakazu

    1989-01-01

    In 31 patients with temporal lobe epilepsy, the precise site of epileptogenic focus was determined by means of a depth EEG recording as one of the presurgical evaluations. In 13 patients, a CT scan revealed focal lesions; 7 in the left temporal lobe and 6 in the right temporal lobe. In 5 of the 7 patients and in 5 of the 6 patients the epileptogenic foci were determined in the temporal lobe on the side of a CT lesion. However, in 2 of the patients with a CT lesion in the left temporal lobe, independent epileptogenic foci were found in both the temporal lobes, and in the other patient with a CT lesion in the right temporal lobe, they were found in the right frontal and left temporal lobes. Thus, the CT lesions agreed in lateralization and focality with the epileptogenic foci in 10 of the 13 patients (77%), but they disagreed in 3 (23%). A CT lesion disclosed in the temporal lobe does not necessarily indicate the side and/or site where the epileptogenic focus may be localized. Although exceptions may be made, spatial disagreement was exemplified between the CT lesion and epileptogenic focus. Therefore, extreme caution has to be taken on the side and/or site of the epileptogenic focus when functional surgical indication is to be made. (author)

  6. Intercomparison On Depth Dose Measurement

    International Nuclear Information System (INIS)

    Rohmah, N; Akhadi, M

    1996-01-01

    Intercomparation on personal dose evaluation system has been carried out between CSRSR-NAEA of Indonesia toward Standard Laboratory of JAERI (Japan) and ARL (Australia). The intercomparison was in 10 amm depth dose measurement , Hp (10), from the intercomparison result could be stated that personal depth dose measurement conducted by CSRSR was sufficiently good. Deviation of dose measurement result using personal dosemeter of TLD BG-1 type which were used by CSRSR in the intercomparison and routine photon personal dose monitoring was still in internationally agreed limit. Maximum deviation of reported doses by CSRSR compared to delivered doses for dosemeter irradiation by JAERI was -10.0 percent and by ARL was +29 percent. Maximum deviation permitted in personal dose monitoring is ± 50 percent

  7. Focal lesions in the central nervous system: stereotaxic radioneurosurgery

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Budinger, T.f.; Hosobuchi, Y.; Born, J.L.; Tobias, C.A.

    1981-01-01

    The application of heavy-ion beams for fundamental and applied brain research has unusual potential. Methods are being developed in our laboratory for producing focal lesions in the central nervous system (e.g., the hypothalamus, thalamus, pituitary gland) to investigate nerve pathways and neuroendocrine responses, and for treating certain pathological disorders of the brain with stereotaxic Bragg peak heavy-ion radiosurgery. Studies in animals are demonstrating the value of this neuroscience tool for investigating mammalian brain response to induction of discrete focal lesions in the hypothalamus or in the cerebral cortex. These studies are also elucidating the neuroendocrinological response follwing ablation of various portions of the midbrain, without requiring complex neurosurgical preparations. Clinical studies are demonstrating the feasibility of stereotaxic neurological radiosurgery for treating certain inoperable vascular disorders of the brain [e.g., arteriovenous malformations (AVM), internal carotid artery-cavernous sinus fistulas and other cerebrovascular disorders] in patients who are already demonstrating progressive neurological deficit. Further applications of focal lesion production with the Bragg ionization peak can be extended to include localized radiation to centers of the brain and spinal cord for treatment of such disorders as Parkinson's disease, pituitary microadenomas, acoustic neuromas, and the control of pain. The eventual application of radioactive beams will provide accurate localization of the stopping points of the beam, thereby making it feasible to stop the beam accurately at a defined depth within the central nervous system

  8. Tensor-guided fitting of subduction slab depths

    Science.gov (United States)

    Bazargani, Farhad; Hayes, Gavin P.

    2013-01-01

    Geophysical measurements are often acquired at scattered locations in space. Therefore, interpolating or fitting the sparsely sampled data as a uniform function of space (a procedure commonly known as gridding) is a ubiquitous problem in geophysics. Most gridding methods require a model of spatial correlation for data. This spatial correlation model can often be inferred from some sort of secondary information, which may also be sparsely sampled in space. In this paper, we present a new method to model the geometry of a subducting slab in which we use a data‐fitting approach to address the problem. Earthquakes and active‐source seismic surveys provide estimates of depths of subducting slabs but only at scattered locations. In addition to estimates of depths from earthquake locations, focal mechanisms of subduction zone earthquakes also provide estimates of the strikes of the subducting slab on which they occur. We use these spatially sparse strike samples and the Earth’s curved surface geometry to infer a model for spatial correlation that guides a blended neighbor interpolation of slab depths. We then modify the interpolation method to account for the uncertainties associated with the depth estimates.

  9. Treatment planning for prostate focal laser ablation in the face of needle placement uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Cepek, Jeremy, E-mail: jcepek@robarts.ca; Fenster, Aaron [Robarts Research Institute, London, Ontario N6A 5K8, Canada and Biomedical Engineering, The University of Western Ontario, London, Ontario N6A 5B9 (Canada); Lindner, Uri; Trachtenberg, John [Department of Surgical Oncology, Division of Urology, University Health Network, Toronto, Ontario M5G 2C4 (Canada); Davidson, Sean R. H. [Ontario Cancer Institute, University Health Network, Toronto, Ontario M5G 2M9 (Canada); Haider, Masoom A. [Department of Medical Imaging, Sunnybrook Health Sciences Center, Toronto, Ontario M4N 3M5, Canada and Department of Medical Imaging, University of Toronto, Toronto, Ontario M5S 2J7 (Canada); Ghai, Sangeet [Department of Medical Imaging, University Health Network, Toronto, Ontario M5G 2M9 (Canada)

    2014-01-15

    Purpose: To study the effect of needle placement uncertainty on the expected probability of achieving complete focal target destruction in focal laser ablation (FLA) of prostate cancer. Methods: Using a simplified model of prostate cancer focal target, and focal laser ablation region shapes, Monte Carlo simulations of needle placement error were performed to estimate the probability of completely ablating a region of target tissue. Results: Graphs of the probability of complete focal target ablation are presented over clinically relevant ranges of focal target sizes and shapes, ablation region sizes, and levels of needle placement uncertainty. In addition, a table is provided for estimating the maximum target size that is treatable. The results predict that targets whose length is at least 5 mm smaller than the diameter of each ablation region can be confidently ablated using, at most, four laser fibers if the standard deviation in each component of needle placement error is less than 3 mm. However, targets larger than this (i.e., near to or exceeding the diameter of each ablation region) require more careful planning. This process is facilitated by using the table provided. Conclusions: The probability of completely ablating a focal target using FLA is sensitive to the level of needle placement uncertainty, especially as the target length approaches and becomes greater than the diameter of ablated tissue that each individual laser fiber can achieve. The results of this work can be used to help determine individual patient eligibility for prostate FLA, to guide the planning of prostate FLA, and to quantify the clinical benefit of using advanced systems for accurate needle delivery for this treatment modality.

  10. Seismicity and seismogenic structures of Central Apennines (Italy): constraints on the present-day stress field from focal mechanisms - The SLAM (Seismicity of Lazio-Abruzzo and Molise) project

    Science.gov (United States)

    Frepoli, Alberto; Battista Cimini, Giovanni; De Gori, Pasquale; De Luca, Gaetano; Marchetti, Alessandro; Montuori, Caterina; Pagliuca, Nicola

    2016-04-01

    We present new results for the microseismic activity in the Central Apennines recorded from a total of 81seismic stations. The large number of recording sites derives from the combination of temporary and permanent seismic networks operating in the study region. Between January 2009 and October 2013 we recorded 6923 earthquakes with local magnitudes ML ranging from 0.1 to 4.8. We located hypocentres by using a refined 1D crustal velocity model. The majority of the hypocenters are located beneath the axes of the Apenninic chain, while the seismic activity observed along the peri-Tyrrhenian margin is lower. The seismicity extends to a depth of 32 km; the hypocentral depth distribution exhibits a pronounced peak of seismic energy release in the depth range between 8 and 20 km. During the observation period we recorded two major seismic swarms and one seismic sequence in the Marsica-Sorano area in which we have had the largest detected magnitude (ML = 4.8). Fault plane solutions for a total of 600 earthquakes were derived from P-polarities. This new data set consists of a number of focal plane solutions that is about four times the data so far available for regional stress field study. The majority of the focal mechanisms show predominantly normal fault solutions. T-axis trends are oriented NE-SW confirming that the area is in extension. We also derived the azimuths of the principal stress axes by inverting the fault plane solutions and calculated the direction of the maximum horizontal stress, which is mainly sub-vertical oriented. The study region has been historically affected by many strong earthquakes, some of them very destructive. This work can give an important contribution to the seismic hazard assessment in an area densely populated as the city of Rome which is distant around 60 km from the main seismogenic structures of Central Apennine.

  11. Systems considerations in mosaic focal planes

    Science.gov (United States)

    White, K. P., III

    1983-08-01

    Two key reasons for pursuing the development of mosaic focal planes are reviewed and it is shown that rapid frame repetition rate is the only requirement that can be solved no other way than through mosaic focal planes. With the view that spaceborne mosaic focal plane sensors are necessarily 'smart sensors' requiring a lot of onboard processing just to function, it is pointed out that various artificial intelligence techniques may be the most appropriate to incorporate in the data processing. Finally, a novel mosaic focal plane design is proposed, termed a virtual mosaic focal plane, in response to other system constraints.

  12. Classification of Focal and Non Focal Epileptic Seizures Using Multi-Features and SVM Classifier.

    Science.gov (United States)

    Sriraam, N; Raghu, S

    2017-09-02

    Identifying epileptogenic zones prior to surgery is an essential and crucial step in treating patients having pharmacoresistant focal epilepsy. Electroencephalogram (EEG) is a significant measurement benchmark to assess patients suffering from epilepsy. This paper investigates the application of multi-features derived from different domains to recognize the focal and non focal epileptic seizures obtained from pharmacoresistant focal epilepsy patients from Bern Barcelona database. From the dataset, five different classification tasks were formed. Total 26 features were extracted from focal and non focal EEG. Significant features were selected using Wilcoxon rank sum test by setting p-value (p z > 1.96) at 95% significance interval. Hypothesis was made that the effect of removing outliers improves the classification accuracy. Turkey's range test was adopted for pruning outliers from feature set. Finally, 21 features were classified using optimized support vector machine (SVM) classifier with 10-fold cross validation. Bayesian optimization technique was adopted to minimize the cross-validation loss. From the simulation results, it was inferred that the highest sensitivity, specificity, and classification accuracy of 94.56%, 89.74%, and 92.15% achieved respectively and found to be better than the state-of-the-art approaches. Further, it was observed that the classification accuracy improved from 80.2% with outliers to 92.15% without outliers. The classifier performance metrics ensures the suitability of the proposed multi-features with optimized SVM classifier. It can be concluded that the proposed approach can be applied for recognition of focal EEG signals to localize epileptogenic zones.

  13. Constraints on fault and crustal strength of the Main Ethiopian Rift from formal inversion of earthquake focal mechanism data

    Science.gov (United States)

    Muluneh, Ameha A.; Kidane, Tesfaye; Corti, Giacomo; Keir, Derek

    2018-04-01

    We evaluate the frictional strength of seismogenic faults in the Main Ethiopian Rift (MER) by inverting the available, well-constrained earthquake focal mechanisms. The regional stress field is given by - 119.6°/77.2°, 6.2°/7.6°, and 97.5°/10.2° for trend/plunge of σ1, σ2 and σ3, respectively agrees well with previous fault kinematic and focal mechanism inversions. We determine the coefficient of friction, μ, for 44 seismogenic faults by assuming the pore pressure to be at hydrostatic conditions. Slip on 36 seismogenic faults occurs with μ ≥ 0.4. Slip on the remaining eight faults is possible with low μ. In general, the coefficient of friction in the MER is compatible with a value of μ of 0.59 ± 0.16 (2σ standard deviation). The shear stresses range from 16 to 129 MPa, is similar to crustal shear stress observed in extensional tectonic regimes and global compilations of shear stresses from major fault zones. The maximum shear stress is observed in the ductile crust, below the seismologically determined brittle-ductile transition (BDT) zone. Below the BDT, the crust is assumed to be weak due to thermal modification and/or high pore fluid pressure. Our results indicate linearly increasing μ and shear stress with depth. We argue that in the MER upper crust is strong and deforms according to Coulomb frictional-failure criterion.

  14. ACCURACY ANALYSIS OF KINECT DEPTH DATA

    Directory of Open Access Journals (Sweden)

    K. Khoshelham

    2012-09-01

    Full Text Available This paper presents an investigation of the geometric quality of depth data obtained by the Kinect sensor. Based on the mathematical model of depth measurement by the sensor a theoretical error analysis is presented, which provides an insight into the factors influencing the accuracy of the data. Experimental results show that the random error of depth measurement increases with increasing distance to the sensor, and ranges from a few millimetres up to about 4 cm at the maximum range of the sensor. The accuracy of the data is also found to be influenced by the low resolution of the depth measurements.

  15. Corrosion pit depth extreme value prediction from limited inspection data

    International Nuclear Information System (INIS)

    Najjar, D.; Bigerelle, M.; Iost, A.; Bourdeau, L.; Guillou, D.

    2004-01-01

    Passive alloys like stainless steels are prone to localized corrosion in chlorides containing environments. The greater the depth of the localized corrosion phenomenon, the more dramatic the related damage that can lead to a structure weakening by fast perforation. In practical situations, because measurements are time consuming and expensive, the challenge is usually to predict the maximum pit depth that could be found in a large scale installation from the processing of a limited inspection data. As far as the parent distribution of pit depths is assumed to be of exponential type, the most successful method was found in the application of the statistical extreme-value analysis developed by Gumbel. This study aims to present a new and alternative methodology to the Gumbel approach with a view towards accurately estimating the maximum pit depth observed on a ferritic stainless steel AISI 409 subjected to an accelerated corrosion test (ECC1) used in automotive industry. This methodology consists in characterising and modelling both the morphology of pits and the statistical distribution of their depths from a limited inspection dataset. The heart of the data processing is based on the combination of two recent statistical methods that avoid making any choice about the type of the theoretical underlying parent distribution of pit depths: the Generalized Lambda Distribution (GLD) is used to model the distribution of pit depths and the Bootstrap technique to determine a confidence interval on the maximum pit depth. (authors)

  16. Depth of maximum of air-shower profiles at the Pierre Auger Observatory. I. Measurements at energies above 10.sup.17.8./sup.  eV

    Czech Academy of Sciences Publication Activity Database

    Aab, A.; Abreu, P.; Aglietta, M.; Boháčová, Martina; Chudoba, Jiří; Ebr, Jan; Mandát, Dušan; Nečesal, Petr; Palatka, Miroslav; Pech, Miroslav; Prouza, Michael; Řídký, Jan; Schovánek, Petr; Trávníček, Petr; Vícha, Jakub

    2014-01-01

    Roč. 90, č. 12 (2014), "122005-1"-"122005-25" ISSN 1550-7998 R&D Projects: GA MŠk(CZ) 7AMB14AR005; GA MŠk(CZ) LG13007; GA ČR(CZ) GA14-17501S Institutional support: RVO:68378271 Keywords : astroparticle physics * Pierre Auger Observatory * cosmic rays * air showers * depth of maximum * Xmax Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 4.643, year: 2014

  17. Intracoronary infusion of catecholamines causes focal arrhythmias in pigs.

    Science.gov (United States)

    Doppalapudi, Harish; Jin, Qi; Dosdall, Derek J; Qin, Hao; Walcott, Gregory P; Killingsworth, Cheryl R; Smith, William M; Ideker, Raymond E; Huang, Jian

    2008-09-01

    Acute ischemia causes myriad changes including increased catecholamines. We tested the hypothesis that elevated catecholamines alone are arrhythmogenic. A 504 electrode sock was placed over both ventricles in six open-chest pigs. During control infusion of saline through a catheter in the left anterior descending coronary artery (LAD), no sustained arrhythmias occurred, and the refractory period estimated by the activation recovery interval (ARI) was 175 +/- 14 ms in the LAD bed below the catheter. After infusion of isoproterenol at 0.1 microg/kg/min through the catheter, the ARI in this bed was significantly reduced to 109 +/- 10 ms. A sharp gradient of refractoriness of 43 +/- 10 ms was at the border of the perfused bed. Sustained monomorphic ventricular tachycardia occurred after drug infusion in the perfused bed or near its boundary in all animals with a cycle length of 329 +/- 26 ms and a focal origin. The maximum slope of the ARI restitution curve at the focal origins of the tachyarrhythmias was always <1 (0.62 +/- 0.15). Similar results with a focal arrhythmia origin occurred in two additional pigs in which intramural mapping was performed with 36 plunge needle electrodes in the left ventricular perfused bed. Regional elevation of a catecholamine, which is one of the alterations produced by acute ischemia, can by itself cause tachyarrhythmias. These arrhythmias are closely associated with a shortened refractory period and a large gradient of the spatial distribution of refractoriness but not with a steep restitution curve.

  18. 'Focal thyroid inferno' on color Doppler ultrasonography: A specific feature of focal Hashimoto's thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Xianshui, E-mail: fuxs1968@163.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Guo, Limei, E-mail: guolimei@bjmu.edu.cn [Department of Pathology, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Zhang, Huabin, E-mail: huabinzhang@bjmu.edu.cn [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Ran, Weiqiang, E-mail: ranwq-sina@vip.sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Fu, Peng, E-mail: fupeng01@gmail.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Li, Zhiqiang, E-mail: lizhq126@126.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Chen, Wen, E-mail: wendy7989@sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Jiang, Ling, E-mail: papayaling@yahoo.com.cn [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Wang, Jinrui, E-mail: jinrui_wang@sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Jia, Jianwen, E-mail: drjia88@sohu.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China)

    2012-11-15

    Purpose: To evaluate color-Doppler features predictive of focal Hashimoto's thyroiditis. Materials and methods: A total of 521 patients with 561 thyroid nodules that underwent surgeries or gun biopsies were included in this study. These nodules were divided into three groups: focal Hashimoto's thyroiditis (104 nodules in 101 patients), benignity other than focal Hashimoto's thyroiditis (73 nodules in 70 patients), and malignancy (358 nodules in 350 patients). On color Doppler sonography, four vascularity types were determined as: hypovascularity, marked internal flow, marked peripheral flow and focal thyroid inferno. The {chi}{sup 2} test was performed to seek the potential vascularity type with the predictive ability of certain thyroid pathology. Furthermore, the gray-scale features of each nodule were also studied. Results: The vascularity type I (hypovascularity) was more often seen in focal Hashimoto's thyroiditis than other benignity and malignancy (46% vs. 20.5% and 19%). While the type II (marked internal flow) showed the opposite tendency (26.9% [focal Hashimoto's thyroiditis] vs. 45.2% [other benignity] and 52.8% [malignancy]). However, type III (marked peripheral flow) was unable to predict any thyroid pathology. Importantly, type IV (focal thyroid inferno) was exclusive to focal Hashimoto's thyroiditis. All 8 type IV nodules appeared to be solid, hypoechoic, and well-defined. Using 'focal thyroid inferno' as an indicator of FHT, the diagnostic sensitivity and specificity were 7.7% and 100% respectively. Conclusions: The vascularity type of 'focal thyroid inferno' is specific for focal Hashimoto thyroiditis. Recognition of this particular feature may avoid unnecessary interventional procedures for some solid hypoechoic thyroid nodules suspicious of malignancy.

  19. Focal dermal hypoplasia without focal dermal hypoplasia

    NARCIS (Netherlands)

    Contreras-Capetillo, Silvina N.; Lombardi, Maria Paola; Pinto-Escalante, Doris; Hennekam, Raoul C.

    2014-01-01

    Focal dermal hypoplasia (FDH; Goltz-Gorlin syndrome) is an X-linked dominant disorder affecting mainly tissues of ectodermal and mesodermal origin. The phenotype is characterized by hypoplastic linear skin lesions, eye malformations, hair and teeth anomalies, and multiple limbs malformations. The

  20. FOCAL EPILEPTIC MYOCLONUS IN KOZHEVNIKOV–RASMUSSEN SYNDROME

    Directory of Open Access Journals (Sweden)

    N. E. Kvaskova

    2016-01-01

    Full Text Available The article presents the clinical, electroencephalographic (EEG and neuroimaging features, as well as the results of treatment of patients with focal epileptic myoclonus (FEM with the Kozhevnikov–Rasmussen syndrome (KRS. FEM in KRS-patients was identified in 11 cases, accounting for 0.9 % of all the cases of epilepsy with the onset of seizures up to 18 years (n = 1261. The age at onset of KRS ranged from 3 to 21 years (average – 9.2 ± 5.7 years. In the active period of the disease of all patients in the clinical picture the active FEM appeared and increasing frequency of the secondary generalized seizures (SGS. In addition SGS and FEM, the clinical picture of the disease in most patients (91 % the focal motor (clonic and the somatosensory focal seizures were observed. As the disease progressed, the FEM became more pronounced in frequency and intensity, seized more muscle groups, localizing mainly in the muscles of the trunk and limbs. The typical EEG pattern of FEM patients with KRS was regional epileptiform activity that occurs in the structure of the continued regional slowing localizing maximum of the fronto-central-temporal region. During the magnetic resonance tomography of the brain in dynamics all the patients observed the increase in total cortical hemiatrophy. In all the cases, the appointment of antiepileptic therapy resulted in a slowing of the FEM, however, a complete remission was reached at none of the patients. Two patients were made surgical treatment of epilepsy. In one case remission of epileptic seizures was observed after right-side hemispherotomy. Our study showed that FEM is very resistant type of epileptic seizures. This fact calls for the identification of the FEM at the early stages of the disease with the purpose to improve the prognosis, as well as for an earlier surgical treatment.

  1. Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement

    International Nuclear Information System (INIS)

    Lerche, Ch.W.; Ros, A.; Monzo, J.M.; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Esteve, R.; Gadea, R.; Colom, R.J.; Toledo, J.; Mateo, F.; Sebastia, A.; Sanchez, F.; Benlloch, J.M.

    2009-01-01

    The center of gravity algorithm leads to strong artifacts for gamma-ray imaging detectors that are based on monolithic scintillation crystals and position sensitive photo-detectors. This is a consequence of using the centroids as position estimates. The fact that charge division circuits can also be used to compute the standard deviation of the scintillation light distribution opens a way out of this drawback. We studied the feasibility of maximum likelihood estimation for computing the true gamma-ray photo-conversion position from the centroids and the standard deviation of the light distribution. The method was evaluated on a test detector that consists of the position sensitive photomultiplier tube H8500 and a monolithic LSO crystal (42mmx42mmx10mm). Spatial resolution was measured for the centroids and the maximum likelihood estimates. The results suggest that the maximum likelihood positioning is feasible and partially removes the strong artifacts of the center of gravity algorithm.

  2. Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lerche, Ch.W. [Grupo de Sistemas Digitales, ITACA, Universidad Politecnica de Valencia, 46022 Valencia (Spain)], E-mail: lerche@ific.uv.es; Ros, A. [Grupo de Fisica Medica Nuclear, IFIC, Universidad de Valencia-Consejo Superior de Investigaciones Cientificas, 46980 Paterna (Spain); Monzo, J.M.; Aliaga, R.J.; Ferrando, N.; Martinez, J.D.; Herrero, V.; Esteve, R.; Gadea, R.; Colom, R.J.; Toledo, J.; Mateo, F.; Sebastia, A. [Grupo de Sistemas Digitales, ITACA, Universidad Politecnica de Valencia, 46022 Valencia (Spain); Sanchez, F.; Benlloch, J.M. [Grupo de Fisica Medica Nuclear, IFIC, Universidad de Valencia-Consejo Superior de Investigaciones Cientificas, 46980 Paterna (Spain)

    2009-06-01

    The center of gravity algorithm leads to strong artifacts for gamma-ray imaging detectors that are based on monolithic scintillation crystals and position sensitive photo-detectors. This is a consequence of using the centroids as position estimates. The fact that charge division circuits can also be used to compute the standard deviation of the scintillation light distribution opens a way out of this drawback. We studied the feasibility of maximum likelihood estimation for computing the true gamma-ray photo-conversion position from the centroids and the standard deviation of the light distribution. The method was evaluated on a test detector that consists of the position sensitive photomultiplier tube H8500 and a monolithic LSO crystal (42mmx42mmx10mm). Spatial resolution was measured for the centroids and the maximum likelihood estimates. The results suggest that the maximum likelihood positioning is feasible and partially removes the strong artifacts of the center of gravity algorithm.

  3. Sighting optics including an optical element having a first focal length and a second focal length

    Science.gov (United States)

    Crandall, David Lynn [Idaho Falls, ID

    2011-08-01

    One embodiment of sighting optics according to the teachings provided herein may include a front sight and a rear sight positioned in spaced-apart relation. The rear sight includes an optical element having a first focal length and a second focal length. The first focal length is selected so that it is about equal to a distance separating the optical element and the front sight and the second focal length is selected so that it is about equal to a target distance. The optical element thus brings into simultaneous focus, for a user, images of the front sight and the target.

  4. Theoretical performance model for single image depth from defocus.

    Science.gov (United States)

    Trouvé-Peloux, Pauline; Champagnat, Frédéric; Le Besnerais, Guy; Idier, Jérôme

    2014-12-01

    In this paper we present a performance model for depth estimation using single image depth from defocus (SIDFD). Our model is based on an original expression of the Cramér-Rao bound (CRB) in this context. We show that this model is consistent with the expected behavior of SIDFD. We then study the influence on the performance of the optical parameters of a conventional camera such as the focal length, the aperture, and the position of the in-focus plane (IFP). We derive an approximate analytical expression of the CRB away from the IFP, and we propose an interpretation of the SIDFD performance in this domain. Finally, we illustrate the predictive capacity of our performance model on experimental data comparing several settings of a consumer camera.

  5. Early vision and focal attention

    Science.gov (United States)

    Julesz, Bela

    1991-07-01

    At the thirty-year anniversary of the introduction of the technique of computer-generated random-dot stereograms and random-dot cinematograms into psychology, the impact of the technique on brain research and on the study of artificial intelligence is reviewed. The main finding-that stereoscopic depth perception (stereopsis), motion perception, and preattentive texture discrimination are basically bottom-up processes, which occur without the help of the top-down processes of cognition and semantic memory-greatly simplifies the study of these processes of early vision and permits the linking of human perception with monkey neurophysiology. Particularly interesting are the unexpected findings that stereopsis (assumed to be local) is a global process, while texture discrimination (assumed to be a global process, governed by statistics) is local, based on some conspicuous local features (textons). It is shown that the top-down process of "shape (depth) from shading" does not affect stereopsis, and some of the models of machine vision are evaluated. The asymmetry effect of human texture discrimination is discussed, together with recent nonlinear spatial filter models and a novel extension of the texton theory that can cope with the asymmetry problem. This didactic review attempts to introduce the physicist to the field of psychobiology and its problems-including metascientific problems of brain research, problems of scientific creativity, the state of artificial intelligence research (including connectionist neural networks) aimed at modeling brain activity, and the fundamental role of focal attention in mental events.

  6. Analytical magmatic source modelling from a joint inversion of ground deformation and focal mechanisms data

    Science.gov (United States)

    Cannavo', Flavio; Scandura, Danila; Palano, Mimmo; Musumeci, Carla

    2014-05-01

    Seismicity and ground deformation represent the principal geophysical methods for volcano monitoring and provide important constraints on subsurface magma movements. The occurrence of migrating seismic swarms, as observed at several volcanoes worldwide, are commonly associated with dike intrusions. In addition, on active volcanoes, (de)pressurization and/or intrusion of magmatic bodies stress and deform the surrounding crustal rocks, often causing earthquakes randomly distributed in time within a volume extending about 5-10 km from the wall of the magmatic bodies. Despite advances in space-based, geodetic and seismic networks have significantly improved volcano monitoring in the last decades on an increasing worldwide number of volcanoes, quantitative models relating deformation and seismicity are not common. The observation of several episodes of volcanic unrest throughout the world, where the movement of magma through the shallow crust was able to produce local rotation of the ambient stress field, introduces an opportunity to improve the estimate of the parameters of a deformation source. In particular, during these episodes of volcanic unrest a radial pattern of P-axes of the focal mechanism solutions, similar to that of ground deformation, has been observed. Therefore, taking into account additional information from focal mechanisms data, we propose a novel approach to volcanic source modeling based on the joint inversion of deformation and focal plane solutions assuming that both observations are due to the same source. The methodology is first verified against a synthetic dataset of surface deformation and strain within the medium, and then applied to real data from an unrest episode occurred before the May 13th 2008 eruption at Mt. Etna (Italy). The main results clearly indicate as the joint inversion improves the accuracy of the estimated source parameters of about 70%. The statistical tests indicate that the source depth is the parameter with the highest

  7. Realization of arbitrarily long focus-depth optical vortices with spiral area-varying zone plates

    Science.gov (United States)

    Zheng, Chenglong; Zang, Huaping; Du, Yanli; Tian, Yongzhi; Ji, Ziwen; Zhang, Jing; Fan, Quanping; Wang, Chuanke; Cao, Leifeng; Liang, Erjun

    2018-05-01

    We provide a methodology to realize an optical vortex with arbitrarily long focus-depth. With a technique of varying each zone area of a phase spiral zone plate one can obtain optics capable of generating ultra-long focus-depth optical vortex from a plane wave. The focal property of such optics was analysed using the Fresnel diffraction theory, and an experimental demonstration was performed to verify its effectiveness. Such optics may bring new opportunity and benefits for optical vortex application such as optical manipulation and lithography.

  8. High bit depth infrared image compression via low bit depth codecs

    Science.gov (United States)

    Belyaev, Evgeny; Mantel, Claire; Forchhammer, Søren

    2017-08-01

    Future infrared remote sensing systems, such as monitoring of the Earth's environment by satellites, infrastructure inspection by unmanned airborne vehicles etc., will require 16 bit depth infrared images to be compressed and stored or transmitted for further analysis. Such systems are equipped with low power embedded platforms where image or video data is compressed by a hardware block called the video processing unit (VPU). However, in many cases using two 8-bit VPUs can provide advantages compared with using higher bit depth image compression directly. We propose to compress 16 bit depth images via 8 bit depth codecs in the following way. First, an input 16 bit depth image is mapped into 8 bit depth images, e.g., the first image contains only the most significant bytes (MSB image) and the second one contains only the least significant bytes (LSB image). Then each image is compressed by an image or video codec with 8 bits per pixel input format. We analyze how the compression parameters for both MSB and LSB images should be chosen to provide the maximum objective quality for a given compression ratio. Finally, we apply the proposed infrared image compression method utilizing JPEG and H.264/AVC codecs, which are usually available in efficient implementations, and compare their rate-distortion performance with JPEG2000, JPEG-XT and H.265/HEVC codecs supporting direct compression of infrared images in 16 bit depth format. A preliminary result shows that two 8 bit H.264/AVC codecs can achieve similar result as 16 bit HEVC codec.

  9. Focal spot size reduction using asymmetric collimation to enable reduced anode angles with a conventional angiographic x-ray tube for use with high resolution detectors

    Science.gov (United States)

    Russ, M.; Shankar, A.; Setlur Nagesh, S. V.; Ionita, C. N.; Bednarek, D. R.; Rudin, S.

    2017-03-01

    The high-resolution requirements for neuro-endovascular image-guided interventions (EIGIs) necessitate the use of a small focal-spot size; however, the maximum tube output limits for such small focal-spot sizes may not enable sufficient x-ray fluence after attenuation through the human head to support the desired image quality. This may necessitate the use of a larger focal spot, thus contributing to the overall reduction in resolution. A method for creating a higher-output small effective focal spot based on the line-focus principle has been demonstrated and characterized. By tilting the C-arm gantry, the anode-side of the x-ray field-of-view is accessible using a detector placed off-axis. This tilted central axis diminishes the resultant focal spot size in the anode-cathode direction by the tangent of the effective anode angle, allowing a medium focal spot to be used in place of a small focal spot with minimal losses in resolution but with increased tube output. Images were acquired of two different objects at the central axis, and with the C-arm tilted away from the central axis at 1° increments from 0°-7°. With standard collimation settings, only 6° was accessible, but using asymmetric extended collimation a maximum of 7° was accessed for enhanced comparisons. All objects were positioned perpendicular to the anode-cathode direction and images were compared qualitatively. The increasing advantage of the off-axis focal spots was quantitatively evidenced at each subsequent angle using the Generalized Measured-Relative Object Detectability metric (GM-ROD). This anode-tilt method is a simple and robust way of increasing tube output for a small field-of-view detector without diminishing the overall apparent resolution for neuro-EIGIs.

  10. X-ray focal spot reconstruction by circular penumbra analysis-Application to digital radiography systems.

    Science.gov (United States)

    Di Domenico, Giovanni; Cardarelli, Paolo; Contillo, Adriano; Taibi, Angelo; Gambaccini, Mauro

    2016-01-01

    The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiograph of a simple test object, acquired with a suitable magnification. The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit. In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera. The method was proven to be effective for simulated

  11. X-ray focal spot reconstruction by circular penumbra analysis—Application to digital radiography systems

    Energy Technology Data Exchange (ETDEWEB)

    Di Domenico, Giovanni, E-mail: didomenico@fe.infn.it; Cardarelli, Paolo; Taibi, Angelo; Gambaccini, Mauro [Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, via Saragat 1, FE I-44122, Italy and INFN - sezione di Ferrara, via Saragat 1, FE I-44122 (Italy); Contillo, Adriano [Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, via Saragat 1, FE I-44122 (Italy)

    2016-01-15

    Purpose: The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiograph of a simple test object, acquired with a suitable magnification. Methods: The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit. Results: In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera. Conclusions: The method was

  12. The maximum significant wave height in the Southern North Sea

    NARCIS (Netherlands)

    Bouws, E.; Tolman, H.L.; Holthuijsen, L.H.; Eldeberky, Y.; Booij, N.; Ferier, P.

    1995-01-01

    The maximum possible wave conditions along the Dutch coast, which seem to be dominated by the limited water depth, have been estimated in the present study with numerical simulations. Discussions with meteorologists suggest that the maximum possible sustained wind speed in North Sea conditions is

  13. Evaluation of Hemodynamics in Focal Steatosis and Focal Spared Lesion of the Liver Using Contrast-Enhanced Ultrasonography with Sonazoid

    International Nuclear Information System (INIS)

    Shiozawa, K.; Watanabe, M.; Ikehara, T.; Kogame, M.; Shinohara, M.; Shinohara, M.; Ishii, K.; Igarashi, Y.; Sumino, Y.; Shiozawa, K.; Makino, H.

    2014-01-01

    We aim to investigate the hemodynamics in focal steatosis and focal spared lesion of the liver using contrast-enhanced ultrasonography (CEUS) with Sonazoid. The subjects were 47 patients with focal steatosis and focal spared lesion. We evaluated enhancement patterns (hyper enhancement, iso enhancement, and hypo enhancement) in the vascular phase and the presence or absence of a hypoechoic area in the post vascular phase for these lesions using CEUS. Of the 24 patients with focal steatosis, the enhancement pattern was iso enhancement in 19 and hypo enhancement in 5. Hypoechoic areas were noted in the post vascular phase in 3 patients. Of the 23 patients with focal spared lesions, the enhancement pattern was iso enhancement in 18 and hyper enhancement in 5. No hypoechoic areas were noted in the post vascular phase in any patient. The hemodynamics in focal steatosis and focal spared lesions in non diffuse fatty liver can be observed using low-invasive procedures in real-time by CEUS. It was suggested that differences in the dynamics of enhancement in the vascular phase of CEUS were influenced by the fat deposits in the target lesion, the surrounding liver parenchyma, and the third inflow.

  14. Evaluation of ML-MC as a Depth Discriminant in Yellowstone, USA and Italy

    Science.gov (United States)

    Li, Z.; Koper, K. D.; Burlacu, R.; Sun, D.; D'Amico, S.

    2017-12-01

    Recent work has shown that the difference between two magnitude scales, ML (local Richter magnitude) and MC (coda/duration magnitude), acts as a depth discriminant in Utah. Shallow seismic sources, such as mining induced earthquakes and explosions, have strongly negative ML-MC values, while deeper tectonic earthquakes have ML-MC values near zero. These observations imply that ML-MC might be effective at discriminating small explosions from deeper natural earthquakes at local distances. In this work, we examine seismicity catalogs for the Yellowstone region and Italy to determine if ML-MCacts as a depth discriminant in these regions as well. We identified 4,780 earthquakes that occurred in the Yellowstone region between Sept. 24, 1994 and March 31, 2017 for which both ML and MC were calculated. The ML-MC distribution is well described by a Gaussian function with a mean of 0.102 and a standard deviation of 0.326. We selected a subset of these events with accurate depths and determined mean ML-MC values in various depth bins. An event depth was considered accurate if the formal depth error was less than 2 km and either (1) the nearest station was within one focal depth or (2) the distance to the nearest station was smaller than the bin size. We find that ML-MC decreases as event depths become shallower than about 10 km. Similar to the results for Utah, the decrease is statistically significant and is robust with respect to small changes in bin size and the criteria used to define accurate depths. We used a similar process to evaluate whether ML-MC was a function of source depth for 63,555 earthquakes that occurred between April 16, 2005 and April 30, 2012 in Italy. The ML-MC values in Italy are also well described by a normal distribution, with a mean of -0.477 and standard deviation of 0.315. We again find a statistically significant decrease in ML-MC for shallow earthquakes. In contrast to the Yellowstone results, for Italy ML-MC decreases at a nearly constant rate

  15. Focal midbrain tumors in children

    NARCIS (Netherlands)

    Vandertop, W. P.; Hoffman, H. J.; Drake, J. M.; Humphreys, R. P.; Rutka, J. T.; Amstrong, D. C.; Becker, L. E.

    1992-01-01

    The clinical and neuroradiological features of focal midbrain tumors in 12 children are described, and the results of their surgical management are presented. Patients with a focal midbrain tumor usually exhibit either symptoms and signs of raised intracranial pressure caused by an obstructive

  16. Diagnostic imaging in focal epilepsy

    International Nuclear Information System (INIS)

    Zlatareva, D.

    2013-01-01

    Focal epilepsies account for 60% of all seizure disorders worldwide. In this review the classic and new classification system of epileptic seizures and syndromes as well as genetic forms are discussed. Magnetic resonance (MR) is the technique of choice for diagnostic imaging in focal epilepsy because of its sensitivity and high tissue contrast. The review is focused on the lack of consensus of imaging protocols and reported findings in refractory epilepsy. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics are depicted. Diagnosis of hippocampal sclerosis and malformations of cortical development as two major causes of refractory focal epilepsy is described in details. Some promising new techniques as positron emission tomography computed tomography (PET/CT) and MR and PET/CT fusion are briefly discussed. Also the relevance of adequate imaging in focal epilepsy, some practical points in imaging interpretation and differential diagnosis are highlighted. (author)

  17. Focal Dystonia in Hemiplegic Upper Limb: Favorable Effect of Cervical Microsurgical DREZotomy Involving the Ventral Horn - A Report of 3 Patients.

    Science.gov (United States)

    Sindou, Marc; Georgoulis, George

    2016-01-01

    Focal dystonia in hemiplegic upper limbs is poorly responsive to medications or classical neurosurgical treatments. Only repeated botulinum toxin injections show efficacy, but in most severe cases effects are transient. Cervical DREZ lesioning, which has proven efficacious in hyperspasticity when done deeply (3-5 mm) in the dorsal horn, may have favorable effects on the dystonic component when performed down to, and including, the base of the ventral horn (5-6 mm in depth). Three patients underwent deep cervical microsurgical DREZotomy (MDT) for focal dystonia in the upper limb. Hypertonia was reduced, and sustained dystonic postures were suppressed. Residual motor function (hidden behind hypertonia) came to the surface. Cervical MDT may be a useful armamentarium for treating refractory focal dystonia in the upper limb. © 2016 S. Karger AG, Basel.

  18. 18 F-FDG uptake in focal organising pneumonia mimicking bronchial carcinoma.

    Science.gov (United States)

    Baha, Ayse; Yildirim, Fatma; Kokturk, Nurdan; Akdemir, Umit Ozgur; Demircan, Sedat; Turktas, Haluk

    2016-11-01

    Organising pneumonia (OP) is not a well-known cause of increased 18 F-FDG uptake, and the relationship of the increased 18 F-FDG uptake to clinical parameters has not been clearly identified. This study aims to assess the role of positron emission tomography-computed tomography (PET-CT) for the diagnosis of focal organised pneumonia that may mimic malignity because of mass-like lesions on the radiological images it causes. Among 40 patients of whom histopathological exams were consistent with OP, medical records of 14 focal OP patients diagnosed with surgical biopsy were evaluated retrospectively. There were 10 male (71.4%) and 4 female (28.6%) patients. The mean age at the time of diagnosis was 57.2 ± 11.7 years, ranging from 38 to 85 years. Nine subjects (64.3%) were smokers. Eleven patients (78.5%) had symptoms, the remaining 3 patients (21.5%) were asymptomatic. Three patients (21.3%) had a history of malignancy. Focal lung lesion was initially detected by chest radiography in 10 patients (71.4%) and by computed tomography (CT) scan in all patients. CT scan showed a single lesion in 12 (85.7%) patients. The lesions were located in the right lung of the half of patients (50%) and in the left lung of the other half. The median diameter of the lesions was 3.4 cm (range, 1.8-6.0 cm). PET with 18 F-FDG was performed in all patients, and hypermetabolic activity of the focal lung lesion was demonstrated in all cases. The median values of maximum standardized uptake value was 3.5 ± 2.7 (min 2.1-max 13.1). Focal OP is a discrete form of OP that is associated with unifocal lesions on radiological images, and it can easily mimic lung cancer because of positivity on PET scans. There are no specific findings of PET scan for the diagnosis of OP. © 2015 John Wiley & Sons Ltd.

  19. Clinical Significance of Incidental Focal 18F-FDG Uptake in the Spinal Cord of Patients with Cancer.

    Science.gov (United States)

    Lim, Chae Hong; Hyun, Seung Hyup; Moon, Seung Hwan; Cho, Young Seok; Choe, Yearn Seong; Lee, Kyung-Han; Kim, Byung-Tae; Choi, Joon Young

    2017-09-01

    We investigated the incidence, location, and clinical significance of focal 18 F-FDG uptake of the spinal cord in patients with cancer. We reviewed the medical records of 22,937 consecutive adult patients with known or suspicious malignancy who underwent 18 F-FDG PET/CT. PET/CT scans with incidental focal spinal cord uptake were selected and retrospectively reviewed to determine the presence, location, number, and maximum standardized uptake value (SUV max ) of any focal hypermetabolic lesions of the spinal cord. In subjects with focal spinal uptake, clinical characteristics and clinical follow-up results, including follow-up PET/CT, were reviewed. Incidental focal spinal cord uptake was observed in 69 of 22,937 adult patients (incidence = 0.3%; M:F = 31:38; age, 55.8 ± 14.7 years). Seventy-eight focal hypermetabolic lesions on spinal cord in the PET/CT scans of the 69 study subjects were analyzed. The most common sites of focal spinal cord uptake were the T12 vertebra (47/78; 60.3%) and L1 vertebra (20/78; 25.6%). Multifocal cord uptake was found in 8 of 69 patients (11.6%). The average SUV max for cord uptake was 2.5 ± 0.5 (range, 1.4∼3.9). There was no clinical or imaging evidence of abnormalities in the spinal cord, both at the time of PET/CT and during clinical follow-up. Although incidental focal 18 F-FDG uptake of the spinal cord is rare in patients with cancer, it may be physiological or benign, but it should not be considered as malignant involvement. Common sites for the uptake were in the T12 and L1 spine levels.

  20. RTG diagnostics of dental focal infection

    International Nuclear Information System (INIS)

    Petrasova, A.; Ondrasovicova, J.; Cecctkova, A.

    2008-01-01

    The theory of focal infection has always been and still is a controversial issue for many dentists and scientists. Even though the focal infection does not occupy the first place in modern medicine, its understanding is imperative. The authors summarized the knowledge about dental focal infection and its relationship to systemic the diseases of the whole body in their publication and they also focused on the radiodiagnostics of this disease. (authors)

  1. Structure of the subducted Cocos Plate from locations of intermediate-depth earthquakes

    Science.gov (United States)

    Lomnitz, C.; Rodríguez-Padilla, L. D.; Castaños, H.

    2013-05-01

    Locations of 3,000 earthquakes of 40 to 300 km depth are used to define the 3-D structure of the subducted Cocos Plate under central and southern Mexico. Discrepancies between deep-seated lineaments and surface tectonics are described. Features of particular interest include: (1) a belt of moderate activity at 40 to 80 km depth that parallels the southern boundary of the Mexican Volcanic Plateau; (2) an offset of 150 km across the Isthmus of Tehuantepec where all seismic activity is displaced toward the northeast; (3) three nests of frequent, deep-seated events (80 to 300 km depth) under southern Veracruz, Chiapas and the coast of Mexico-Guatemala. The active subduction process is sharply delimited along a NW-SE lineament from the Yucatan Peninsula, of insignificant earthquake activity. The focal distribution of intermediate-depth earthquakes in south-central Mexico provides evidence of stepwise deepening of the subduction angle along the Trench, starting at 15 degrees under Michoacan-Guerrero to 45 degrees under NW Guatemala. Historical evidence suggests that the hazard to Mexico City from large intermediate-depth earthquakes may have been underestimated.

  2. Development of measurement technique for crack depth in weld zone of thick stainless steel pipe with ultrasonic phased array TOFD

    International Nuclear Information System (INIS)

    Ishida, Hitoshi

    2006-01-01

    Phased array TOFD (time of flight diffraction) method which makes possible to detect tip diffraction echoes and measure crack depth in an austenitic stainless steel weld zone with a thickness of more than 25 mm to which region it was difficult to apply ultrasonic test due to scattering of ultrasonic waves has been developed. The developed method uses a single array transducer to have a short distance between incident points of transmitter and receiver in order to propagate waves in shorter pass in the weld region. Transmitting and receiving ultrasonic beams from a single array probe can be set a crossing point and a focal point at desired depth. This method makes possible to scan with 16 kinds of combination of crossing points and focal pints of ultrasonic beam at a time. We have examined fundamental characteristics of depth measurement with electric discharge machining slits on base metal of a stainless steel with a thickness of 35 mm. As the results: (1) We could measure the slit depth with 0.2mm error from the slit depth with a estimating method of a lateral wave propagation time with back wall echo. (2) The largest error of the depth measurement from the slit depth with the ultrasonic beam crossing point set at the 4mm different point from the tip of the slit was 0.3 mm. (3) The largest error of the depth measurements due to the difference of focal point depth of ultrasonic beam was 0.2 mm. (4) The highest tip diffraction echo could be observed with the ultrasonic beam cross point set at the tip of the slit. The difference of 4 mm between the cross point and the tip of the slit caused attenuation of tip diffraction echo height in -6.8 dB. Furthermore we have measured a depth of electric discharge machining slits, fatigue cracks and stress corrosion cracking (SCC) on stainless steel welded pipe specimens with a thickness of 35 mm. As the results: (1) We could detect the tip diffraction echoes which have a signal noise ratio with more than 2.4 from the fatigue

  3. Incidental Focal 18F FDG Uptake in the Prostate: Clinical Significance and Differential Diagnostic Criteria

    International Nuclear Information System (INIS)

    Cho, Suk Kyong; Choi, Joon Young; Yoo, Jang; Cheon, Miju; Lee, Ji Young; Hyun, Seung Hyup; Lee, Eun Jeong; Lee, Kyung Han; Kim, Byung Tae

    2011-01-01

    The extent and intensity of 18F FDG uptake in prostate cancer patients are known to be variable, and the clinical significance of focal 18F fluorodeoxyglucose ( 18F FDG) uptake that is incidentally found on positron emission tomography (PET) has not been established. We investigated the clinical significance of incidental focal prostate uptake of 18F FDG on PET/computed tomography (CT) and analyzed differential findings on PET/CT Between malignant and benign uptake. A total of 14,854 whole body 18F FDG PET/CT scans (4,806 that were conducted during cancer screening and 10,048 that were conducted to evaluate suspected of alleged cancer outside of the prostate) were retrospectively reviewed to determine the presence, location, multiplicity reviewed to determine the presence, location, multiplicity and maximum standardized uptake value (SUVmax) of focal prostate uptake and combined calcification. The final diagnosis determined by serum prostate specific antigen (PSA) level and biopsy was compared with PET findings. Incidental focal prostate uptake was observed in 148 of 14,854 scans (1.0%). Sixty seven of these 148 subjects who had diagnostic confirmation were selected for further analysis. Prostate cancer was diagnosed in nine of 67 subjects (13.4%). The remaining 58 subjects had no malignancy in the prostate based on normal serum PSA level (n=53), or elevated serum PSA level with a negative biopsy result (n=5). While 84.6% (11/13) of malignant uptake was peripherally located in the prostate glands, 60.2% (50/83) of benign uptake was centrally located (p 18F FDG uptake un the prostate is not common, the incidence of cancer with focal uptake is not low. Therefore, these findings deserve further evaluation. The location of the focal prostate uptake may help with the selection of high risk prostate cancer patients.

  4. The dispersion-focalization theory of sound systems

    Science.gov (United States)

    Schwartz, Jean-Luc; Abry, Christian; Boë, Louis-Jean; Vallée, Nathalie; Ménard, Lucie

    2005-04-01

    The Dispersion-Focalization Theory states that sound systems in human languages are shaped by two major perceptual constraints: dispersion driving auditory contrast towards maximal or sufficient values [B. Lindblom, J. Phonetics 18, 135-152 (1990)] and focalization driving auditory spectra towards patterns with close neighboring formants. Dispersion is computed from the sum of the inverse squared inter-spectra distances in the (F1, F2, F3, F4) space, using a non-linear process based on the 3.5 Bark critical distance to estimate F2'. Focalization is based on the idea that close neighboring formants produce vowel spectra with marked peaks, easier to process and memorize in the auditory system. Evidence for increased stability of focal vowels in short-term memory was provided in a discrimination experiment on adult French subjects [J. L. Schwartz and P. Escudier, Speech Comm. 8, 235-259 (1989)]. A reanalysis of infant discrimination data shows that focalization could well be the responsible for recurrent discrimination asymmetries [J. L. Schwartz et al., Speech Comm. (in press)]. Recent data about children vowel production indicate that focalization seems to be part of the perceptual templates driving speech development. The Dispersion-Focalization Theory produces valid predictions for both vowel and consonant systems, in relation with available databases of human languages inventories.

  5. Seven tesla MRI improves detection of focal cortical dysplasia in patients with refractory focal epilepsy

    NARCIS (Netherlands)

    Veersema, Tim J; Ferrier, Cyrille H; van Eijsden, Pieter; Gosselaar, Peter H; Aronica, Eleonora; Visser, Fredy; Zwanenburg, Jaco M; de Kort, Gerard A P; Hendrikse, Jeroen; Luijten, Peter R; Braun, Kees P J

    Objective: The aim of this study is to determine whether the use of 7 tesla (T) MRI in clinical practice leads to higher detection rates of focal cortical dysplasias in possible candidates for epilepsy surgery. Methods: In our center patients are referred for 7 T MRI if lesional focal epilepsy is

  6. Clinical significance of incidental focal "1"8F-FDG uptake in the spinal cord of patients with cancer

    International Nuclear Information System (INIS)

    Lim, Chae Hong; Hyun, Seung Hyup; Moon, Seung Hwan; Cho, Young Seok; Choe, Yearn Seong; Lee, Kyung Han; Kim, Byung Tae; Choi, Joon Young

    2017-01-01

    We investigated the incidence, location, and clinical significance of focal "1"8F-FDG uptake of the spinal cord in patients with cancer. We reviewed the medical records of 22,937 consecutive adult patients with known or suspicious malignancy who underwent "1"8F-FDG PET/CT. PET/CT scans with incidental focal spinal cord uptake were selected and retrospectively reviewed to determine the presence, location, number, and maximum standardized uptake value (SUV_m_a_x) of any focal hypermetabolic lesions of the spinal cord. In subjects with focal spinal uptake, clinical characteristics and clinical follow-up results, including follow-up PET/CT, were reviewed. Incidental focal spinal cord uptake was observed in 69 of 22,937 adult patients (incidence = 0.3%; M:F = 31:38; age, 55.8 ± 14.7 years). Seventy-eight focal hypermetabolic lesions on spinal cord in the PET/CT scans of the 69 study subjects were analyzed. The most common sites of focal spinal cord uptake were the T12 vertebra (47/78; 60.3%) and L1 vertebra (20/78; 25.6%). Multifocal cord uptake was found in 8 of 69 patients (11.6%). The average SUVmax for cord uptake was 2.5 ± 0.5 (range, 1.4∼3.9). There was no clinical or imaging evidence of abnormalities in the spinal cord, both at the time of PET/CT and during clinical follow-up. Although incidental focal "1"8F-FDG uptake of the spinal cord is rare in patients with cancer, it may be physiological or benign, but it should not be considered as malignant involvement. Common sites for the uptake were in the T12 and L1 spine levels

  7. Clinical significance of incidental focal {sup 18}F-FDG uptake in the spinal cord of patients with cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Chae Hong; Hyun, Seung Hyup; Moon, Seung Hwan; Cho, Young Seok; Choe, Yearn Seong; Lee, Kyung Han; Kim, Byung Tae; Choi, Joon Young [Dept. of Nuclear Medicine, Samsung Medical CenterSungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-09-15

    We investigated the incidence, location, and clinical significance of focal {sup 18}F-FDG uptake of the spinal cord in patients with cancer. We reviewed the medical records of 22,937 consecutive adult patients with known or suspicious malignancy who underwent {sup 18}F-FDG PET/CT. PET/CT scans with incidental focal spinal cord uptake were selected and retrospectively reviewed to determine the presence, location, number, and maximum standardized uptake value (SUV{sub max}) of any focal hypermetabolic lesions of the spinal cord. In subjects with focal spinal uptake, clinical characteristics and clinical follow-up results, including follow-up PET/CT, were reviewed. Incidental focal spinal cord uptake was observed in 69 of 22,937 adult patients (incidence = 0.3%; M:F = 31:38; age, 55.8 ± 14.7 years). Seventy-eight focal hypermetabolic lesions on spinal cord in the PET/CT scans of the 69 study subjects were analyzed. The most common sites of focal spinal cord uptake were the T12 vertebra (47/78; 60.3%) and L1 vertebra (20/78; 25.6%). Multifocal cord uptake was found in 8 of 69 patients (11.6%). The average SUVmax for cord uptake was 2.5 ± 0.5 (range, 1.4∼3.9). There was no clinical or imaging evidence of abnormalities in the spinal cord, both at the time of PET/CT and during clinical follow-up. Although incidental focal {sup 18}F-FDG uptake of the spinal cord is rare in patients with cancer, it may be physiological or benign, but it should not be considered as malignant involvement. Common sites for the uptake were in the T12 and L1 spine levels.

  8. Periodontitis in patients with focal tuberculosis

    Directory of Open Access Journals (Sweden)

    Alexandrova Е.А.

    2010-12-01

    Full Text Available The research goal is to investigate the mechanisms of formation and peculiarities of periodontitis in patients with focal tuberculosis. Patients with periodontitis and focal tuberculosis are proved to develop local inflammatory reaction with increased infection and activation of proinflammatory cytokines in parodontal pockets fluid. The main risk factor of frequent and durable recurrence of parodontal pathology in case of focal tuberculosis was the development of pathologic process as a cause of disbalance of lipid peroxidation and antioxidant system, endotoxicosis syndrome

  9. Expansive focal cemento-osseous dysplasia.

    Science.gov (United States)

    Bulut, Emel Uzun; Acikgoz, Aydan; Ozan, Bora; Zengin, Ayse Zeynep; Gunhan, Omer

    2012-01-01

    To present a case of expansive focal cemento-osseous dysplasia and emphasize the importance of differential diagnosis. Cemento-osseous dysplasia is categorized into three subtypes on the basis of the clinical and radiographic features: Periapical, focal and florid. The focal type exhibits a single site of involvement in any tooth-bearing or edentulous area of the jaws. These lesions are usually asymptomatic; therefore, they are frequently diagnosed incidentally during routine radiographic examinations. Lesions are usually benign, show limited growth, and do not require further surgical intervention, but periodic follow-up is recommended because occasionally, this type of dysplasia progresses into florid osseous dysplasia and simple bone cysts are formed. A 24-year-old female patient was referred to our clinic for swelling in the left edentulous mandibular premolarmolar region and felt discomfort when she wore her prosthetics. She had no pain, tenderness or paresthesia. Clinical examination showed that the swelling in the posterior mandible that was firm, nonfluctuant and covered by normal mucosa. On panoramic radiography and computed tomography, a well defined lesion of approximately 1.5 cm in diameter of mixed density was observed. The swelling increased slightly in size over 2 years making it difficult to use prosthetics and, therefore, the lesion was totally excised under local anesthesia, and surgical specimens were submitted for histopathological examination. The histopathological diagnosis was focal cemento-osseous dysplasia. In the present case, because of the increasing size of the swelling making it difficult to use prosthetics, young age of the patient and localization of the lesion, in the initial examination, cemento-ossifying fibroma was suspected, and the lesion was excised surgically; the histopathological diagnosis confirmed it as focal cemento-osseous dysplasia. We present a case of expansive focal cemento-osseous dysplasia. Differential diagnosis

  10. Depth of source from long period P-waves

    International Nuclear Information System (INIS)

    Roy, Falguni

    1986-01-01

    Short period (SP) seismograms are much better than long period (LP) seismograms to get the time resolution needed for the focal depth estimation. However, complex scattering effects due to crustal inhomogeneities and also the multi-pathing of signals usually complicate the short period records. On the other hand the seismograms from long period signals demonstrate clear coherent body waves. Therefore, for intermediate depths (15-60 km) prediction error filtering of LP signals will be useful for identifying the depth phases. Such a study has been carried out in the first part of this report. In a group of 7 events, the p p phases have been extracted from LP signals and the depths so estimated compared well with the published data. For explosions at shallow depths (depth p phases will tend to cancel each other in LP seismograms. As the source depth increases, the cancellation becomes less effective. This feature can be used for the identification of an event as well as for getting an estimate of the source depth. This phenomenon can be successfully exploited for identifying multiple explosions, because at teleseismic distances (Δ > 30 o ) no LP (around 20s period) P waves will be seen in the seismogram due to such events whereas relatively strong SP signals and LP Rayleigh waves will be observed. This phenomenon has been studied for 16 events. For three of these events having m b as high as 6.1 and presumed to be underground explosions, one could not see any P wave on remaining 13 events (which were classified as earthquakes), it was possible to set a threshold value of m b above which an earthquake should produce LP P-wave signals at a given distance. (author)

  11. Incidental focal FDG uptake in the parotid glands on PET/CT in patients with head and neck malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Lan; Yoon, Dae Young; Lim, Kyoung Ja; Yun, Eun Joo; Cho, Young Kwon [Hallym University College of Medicine, Department of Radiology, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of); Baek, Sora [Hallym University College of Medicine, Department of Nuclear Medicine, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of); Bae, Woo Jin; Chung, Eun Jae; Kwon, Kee Hwan [Hallym University College of Medicine, Department of Otorhinolaryngology, Ilsong Memorial Institute of Head and Neck Cancer, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of)

    2015-01-15

    To evaluate the prevalence and clinical significance of focal parotid lesions identified by {sup 18} F- FDG PET/CT in patients with nonparotid head and neck malignancies. From 3,638 PET/CT examinations using {sup 18} F-FDG conducted on 1,342 patients with nonparotid head and neck malignancies, we retrospectively identified patients showing incidental focal FDG uptake in the parotid glands. The diagnosis of parotid lesions was confirmed histopathologically or on imaging follow-up. Patient demographics, clinical features, maximum standardized uptake value (SUV{sub max}) on PET images, size and attenuation on corresponding contrast-enhanced CT images were assessed and correlated with the final diagnosis. The prevalence of incidental focal parotid FDG uptake on PET/CT was 2.1 % (95 % CI 1.4 - 3.0 %). Among 21 patients with focal parotid lesions confirmed histologically or on imaging follow-up, 7 (33.3 %) had malignant lesions (all metastases) and 14 (66.7 %) had benign lesions (four pleomorphic adenomas, two Warthin's tumours, one benign lymph node, one granulomatous lesion, six lesions without histopathological confirmation). There were no significant differences in age, sex, SUV{sub max} or CT findings between patients with benign and those with malignant lesions. Focal parotid FDG uptake on PET/CT in patients with head and neck malignancy warrants further investigations to ensure adequate therapy for incidental parotid lesions. (orig.)

  12. An empirical assessment of the focal species hypothesis.

    Science.gov (United States)

    Lindenmayer, D B; Lane, P W; Westgate, M J; Crane, M; Michael, D; Okada, S; Barton, P S

    2014-12-01

    Biodiversity surrogates and indicators are commonly used in conservation management. The focal species approach (FSA) is one method for identifying biodiversity surrogates, and it is underpinned by the hypothesis that management aimed at a particular focal species will confer protection on co-occurring species. This concept has been the subject of much debate, in part because the validity of the FSA has not been subject to detailed empirical assessment of the extent to which a given focal species actually co-occurs with other species in an assemblage. To address this knowledge gap, we used large-scale, long-term data sets of temperate woodland birds to select focal species associated with threatening processes such as habitat isolation and loss of key vegetation attributes. We quantified co-occurrence patterns among focal species, species in the wider bird assemblage, and species of conservation concern. Some, but not all, focal species were associated with high levels of species richness. One of our selected focal species was negatively associated with the occurrence of other species (i.e., it was an antisurrogate)-a previously undescribed property of nominated focal species. Furthermore, combinations of focal species were not associated with substantially elevated levels of bird species richness, relative to levels associated with individual species. Our results suggest that although there is some merit to the underpinning concept of the FSA, there is also a need to ensure that actions are sufficiently flexible because management tightly focused on a given focal species may not benefit some other species, including species of conservation concern, such of which might not occur in species-rich assemblages. © 2014 Society for Conservation Biology.

  13. SU-G-206-02: Impact of Focal Spot Sizes On CT Image Quality

    International Nuclear Information System (INIS)

    Bache, S; Rong, J

    2016-01-01

    Purpose: To quantify a radiology team’s assessment of image quality differences between two CT scanner models currently in clinical use, with emphasis on spatial resolution that could be impacted by focal spot size. Methods: Modulation Transfer Functions (MTF) measurements were performed by scanning the impulse source insert module of the Catphan 600 at 120/140 kVp with both large (LFS) and small (SFS) focal spots and reconstructed to 2.5mm and 5.0mm thicknesses on a GE Discovery CT750 HD and a LightSpeed VCT CT scanner. MTFs were calculated by summing the 2D PSF along one-dimension to obtain line-spread-function (LSF), and calculating the Fourier Transform of the zero-padded and background corrected LSF. Spatial resolution performance was evaluated by comparing MTF curves, 50% and 10% MTF cutoff, and total area under the MTF curve (AUC). In addition, images of the Catphan high-contrast module and a Kagaku anthropomorphic body phantom were acquired from the HD scanner for visual comparisons. Results: For each scanner model, SFS was superior to LFS spatial resolution with respect to 50%/10% MTF cutoff and AUC. For the HD, 50%/10% cutoff was 4.29/7.22cm-1 for the LFS and 4.43/7.45cm-1 for the SFS. VCT outperformed HD, with 50%/10% cutoff of 4.40/7.29 cm-1 for LFS and 4.62/7.47cm-1 for SFS. Scanner model performance in order of decreasing AUC performance was VCT SFS (7.43), HD SFS (7.20), VCT LFS (7.09) and HD LFS (6.93). Visual evaluations of Kagaku phantom images confirmed that VCT outperformed HD. Conclusion: VCT outperformed HD and small focal spot is desired for either model over large focal spot in term of spatial resolution – in agreement with radiologist feedback of overall image quality. In-depth evaluations of clinical impact and focal spot selection mechanisms is currently being assessed.

  14. Spatiotemporal fusion of multiple-satellite aerosol optical depth (AOD) products using Bayesian maximum entropy method

    Science.gov (United States)

    Tang, Qingxin; Bo, Yanchen; Zhu, Yuxin

    2016-04-01

    Merging multisensor aerosol optical depth (AOD) products is an effective way to produce more spatiotemporally complete and accurate AOD products. A spatiotemporal statistical data fusion framework based on a Bayesian maximum entropy (BME) method was developed for merging satellite AOD products in East Asia. The advantages of the presented merging framework are that it not only utilizes the spatiotemporal autocorrelations but also explicitly incorporates the uncertainties of the AOD products being merged. The satellite AOD products used for merging are the Moderate Resolution Imaging Spectroradiometer (MODIS) Collection 5.1 Level-2 AOD products (MOD04_L2) and the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Deep Blue Level 2 AOD products (SWDB_L2). The results show that the average completeness of the merged AOD data is 95.2%,which is significantly superior to the completeness of MOD04_L2 (22.9%) and SWDB_L2 (20.2%). By comparing the merged AOD to the Aerosol Robotic Network AOD records, the results show that the correlation coefficient (0.75), root-mean-square error (0.29), and mean bias (0.068) of the merged AOD are close to those (the correlation coefficient (0.82), root-mean-square error (0.19), and mean bias (0.059)) of the MODIS AOD. In the regions where both MODIS and SeaWiFS have valid observations, the accuracy of the merged AOD is higher than those of MODIS and SeaWiFS AODs. Even in regions where both MODIS and SeaWiFS AODs are missing, the accuracy of the merged AOD is also close to the accuracy of the regions where both MODIS and SeaWiFS have valid observations.

  15. Managing Innovation Paradox in the Sustainable Innovation Ecosystem: A Case Study of Ambidextrous Capability in a Focal Firm

    Directory of Open Access Journals (Sweden)

    Delin Zeng

    2017-11-01

    Full Text Available To achieve sustainable development, focal firms should balance two paradoxical kinds of innovation activities: exploitative and exploratory ones. Published works found that ambidexterity is an effective way to resolve paradoxical tensions, but few in-depth studies have been conducted to explore the innovation paradox of focal firms in the innovation ecosystem from an ambidextrous capability perspective. This paper takes China Spacesat Co., Ltd. as the case to study focal firms’ management of innovation paradoxes in the sustainable innovation ecosystem and finds that: (1 Sustainable innovation is an ecosystem in which focal firms’ internal functional departments, including the product department, technical center, and Makers’ groups, cooperate with external organizations, including component suppliers, scientific research institutes, and government departments, closely and complementarily; (2 In the exploitative and exploratory innovations of complex products, focal firms in the sustainable innovation ecosystem mainly confront three paradoxes: profit drive vs. breakthroughs in the strategic intent of sustainable innovation of the profit-driven model, tight vs. loose coupling of sustainable innovation, and sustainable innovation driven by discipline vs. that by passion; (3 Focal firms in the innovation ecosystem resolve these three innovation paradoxes with structural, contextual, and coordinated ambidextrous capabilities, and build innovation paradox management mechanisms with three steps in sequence, namely by establishing dual sustainable strategic innovation units, strengthening sustainable organizational ties between the internal and external, while co-creating and sharing innovation values, and, finally, promoting the formation and development of their sustainable innovation ecosystem. This paper complements and enriches the innovation ecosystem and ambidextrous capability theory, providing significant practical guidance to the

  16. Experimental Focal Cerebral Ischemia

    DEFF Research Database (Denmark)

    Christensen, Thomas

    2007-01-01

    Focal cerebral ischemia due to occlusion of a major cerebral artery is the cause of ischemic stroke which is a major reason of mortality, morbidity and disability in the populations of the developed countries. In the seven studies summarized in the thesis focal ischemia in rats induced by occlusion...... in the penumbra is recruited in the infarction process leading to a progressive growth of the infarct. The penumbra hence constitutes an important target for pharmacological treatment because of the existence of a therapeutic time window during which treatment with neuroprotective compounds may prevent...

  17. Sighting optics including an optical element having a first focal length and a second focal length and methods for sighting

    Science.gov (United States)

    Crandall, David Lynn

    2011-08-16

    Sighting optics include a front sight and a rear sight positioned in a spaced-apart relation. The rear sight includes an optical element having a first focal length and a second focal length. The first focal length is selected so that it is about equal to a distance separating the optical element and the front sight and the second focal length is selected so that it is about equal to a target distance. The optical element thus brings into simultaneous focus for a user images of the front sight and the target.

  18. Do focal colors look particularly "colorful"?

    Science.gov (United States)

    Witzel, Christoph; Franklin, Anna

    2014-04-01

    If the most typical red, yellow, green, and blue were particularly colorful (i.e., saturated), they would "jump out to the eye." This would explain why even fundamentally different languages have distinct color terms for these focal colors, and why unique hues play a prominent role in subjective color appearance. In this study, the subjective saturation of 10 colors around each of these focal colors was measured through a pairwise matching task. Results show that subjective saturation changes systematically across hues in a way that is strongly correlated to the visual gamut, and exponentially related to sensitivity but not to focal colors.

  19. Variations in depth-dose data between open and wedge fields for 4-MV x-rays

    International Nuclear Information System (INIS)

    Sewchand, W.; Khan, F.M.; Williamson, J.

    1978-01-01

    Central-axis depth-dose data for 4-MV x rays, including tissue-maximum ratios, were measured for wedge fields. Comparison with corresponding open-field data revealed differences in magnitude which increased with depth, field size, and wedge thickness. However, phantom scatter correction factors for the wedge fields differed less than 1% from corresponding open-field factors. The differences in central-axis percent depth doses between the two types of fields indicate beam hardening by the wedge filter. This study also implies that the derivation of tissue-maximum ratios from central-axis percent depth is as valid for wedge as for open fields

  20. Inverse-designed stretchable metalens with tunable focal distance

    Science.gov (United States)

    Callewaert, Francois; Velev, Vesselin; Jiang, Shizhou; Sahakian, Alan Varteres; Kumar, Prem; Aydin, Koray

    2018-02-01

    In this paper, we present an inverse-designed 3D-printed all-dielectric stretchable millimeter wave metalens with a tunable focal distance. A computational inverse-design method is used to design a flat metalens made of disconnected polymer building blocks with complex shapes, as opposed to conventional monolithic lenses. The proposed metalens provides better performance than a conventional Fresnel lens, using lesser amount of material and enabling larger focal distance tunability. The metalens is fabricated using a commercial 3D-printer and attached to a stretchable platform. Measurements and simulations show that the focal distance can be tuned by a factor of 4 with a stretching factor of only 75%, a nearly diffraction-limited focal spot, and with a 70% relative focusing efficiency, defined as the ratio between power focused in the focal spot and power going through the focal plane. The proposed platform can be extended for design and fabrication of multiple electromagnetic devices working from visible to microwave radiation depending on scaling of the devices.

  1. A Novel Method for Remote Depth Estimation of Buried Radioactive Contamination.

    Science.gov (United States)

    Ukaegbu, Ikechukwu Kevin; Gamage, Kelum A A

    2018-02-08

    Existing remote radioactive contamination depth estimation methods for buried radioactive wastes are either limited to less than 2 cm or are based on empirical models that require foreknowledge of the maximum penetrable depth of the contamination. These severely limits their usefulness in some real life subsurface contamination scenarios. Therefore, this work presents a novel remote depth estimation method that is based on an approximate three-dimensional linear attenuation model that exploits the benefits of using multiple measurements obtained from the surface of the material in which the contamination is buried using a radiation detector. Simulation results showed that the proposed method is able to detect the depth of caesium-137 and cobalt-60 contamination buried up to 40 cm in both sand and concrete. Furthermore, results from experiments show that the method is able to detect the depth of caesium-137 contamination buried up to 12 cm in sand. The lower maximum depth recorded in the experiment is due to limitations in the detector and the low activity of the caesium-137 source used. Nevertheless, both results demonstrate the superior capability of the proposed method compared to existing methods.

  2. Spinal focal lesion detection in multiple myeloma using multimodal image features

    Science.gov (United States)

    Fränzle, Andrea; Hillengass, Jens; Bendl, Rolf

    2015-03-01

    Multiple myeloma is a tumor disease in the bone marrow that affects the skeleton systemically, i.e. multiple lesions can occur in different sites in the skeleton. To quantify overall tumor mass for determining degree of disease and for analysis of therapy response, volumetry of all lesions is needed. Since the large amount of lesions in one patient impedes manual segmentation of all lesions, quantification of overall tumor volume is not possible until now. Therefore development of automatic lesion detection and segmentation methods is necessary. Since focal tumors in multiple myeloma show different characteristics in different modalities (changes in bone structure in CT images, hypointensity in T1 weighted MR images and hyperintensity in T2 weighted MR images), multimodal image analysis is necessary for the detection of focal tumors. In this paper a pattern recognition approach is presented that identifies focal lesions in lumbar vertebrae based on features from T1 and T2 weighted MR images. Image voxels within bone are classified using random forests based on plain intensities and intensity value derived features (maximum, minimum, mean, median) in a 5 x 5 neighborhood around a voxel from both T1 and T2 weighted MR images. A test data sample of lesions in 8 lumbar vertebrae from 4 multiple myeloma patients can be classified at an accuracy of 95% (using a leave-one-patient-out test). The approach provides a reasonable delineation of the example lesions. This is an important step towards automatic tumor volume quantification in multiple myeloma.

  3. Effects on patient exposure dose and image quality by increasing focal film distance in abdominal radiography

    International Nuclear Information System (INIS)

    Kim, You Hyun; Kwon, Soo Il

    1998-01-01

    We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce thr patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowadays, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows ; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data

  4. Pharmacological response of systemically derived focal epileptic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Remler, M.P.; Sigvardt, K.; Marcussen, W.H.

    1986-11-01

    Focal epileptic lesions were made in rats by systemic focal epileptogenesis. In this method, a focal lesion of the blood-brain barrier (BBB) is produced by focal alpha irradiation followed by repeated systemic injection of a convulsant drug that cannot cross the normal BBB, resulting in a chronic epileptic focus. Changes in the spike frequency of these foci in response to various drugs was recorded. The controls, saline and chlorpromazine, produced no change. Phenytoin, phenobarbital, chlordiazepoxide, and valproic acid produced the expected decrease in spike frequency. Pentobarbital and diazepam produced a paradoxical increase in spike frequency.

  5. Details of microearthquake swarms in the Columbia basin, Washington

    International Nuclear Information System (INIS)

    Malone, S.D.; Rothe, G.H.; Smith, S.W.

    1975-01-01

    Three microearthquake swarms in the Columbia River basin of eastern Washington were studied by means of a small portable seismic network. Earthquakes in this area typically occur in swarms, concentrated both temporally and spatially. One unusual characteristic of the three swarms studied was the shallow focal depths of all events. Most events located had depths less than 1 km; none were deeper than 2 km. Composite focal mechanism solutions indicate that more than one fault surface is active in any one swarm. All events had some thrust component with the axis of maximum compression oriented roughly in a north-south direction. (auth)

  6. Recurrent Bilateral Focal Myositis.

    Science.gov (United States)

    Nagafuchi, Hiroko; Nakano, Hiromasa; Ooka, Seido; Takakuwa, Yukiko; Yamada, Hidehiro; Tadokoro, Mamoru; Shimojo, Sadatomo; Ozaki, Shoichi

    This report describes a rare case of recurrent bilateral focal myositis and its successful treatment via methotrexate. A 38-year-old man presented myalgia of the right gastrocnemius in May 2005. Magnetic resonance imaging showed very high signal intensity in the right gastrocnemius on short-tau inversion recovery images. A muscle biopsy revealed inflammatory CD4+ cell-dominant myogenic change. Focal myositis was diagnosed. The first steroid treatment was effective. Tapering of prednisolone, however, repeatedly induced myositis relapse, which progressed to multiple muscle lesions of both lower limbs. Initiation of methotrexate finally allowed successful tapering of prednisolone, with no relapse in the past 4 years.

  7. Focal switching of photochromic fluorescent proteins enables multiphoton microscopy with superior image contrast.

    Science.gov (United States)

    Kao, Ya-Ting; Zhu, Xinxin; Xu, Fang; Min, Wei

    2012-08-01

    Probing biological structures and functions deep inside live organisms with light is highly desirable. Among the current optical imaging modalities, multiphoton fluorescence microscopy exhibits the best contrast for imaging scattering samples by employing a spatially confined nonlinear excitation. However, as the incident laser power drops exponentially with imaging depth into the sample due to the scattering loss, the out-of-focus background eventually overwhelms the in-focus signal, which defines a fundamental imaging-depth limit. Herein we significantly improve the image contrast for deep scattering samples by harnessing reversibly switchable fluorescent proteins (RSFPs) which can be cycled between bright and dark states upon light illumination. Two distinct techniques, multiphoton deactivation and imaging (MPDI) and multiphoton activation and imaging (MPAI), are demonstrated on tissue phantoms labeled with Dronpa protein. Such a focal switch approach can generate pseudo background-free images. Conceptually different from wave-based approaches that try to reduce light scattering in turbid samples, our work represents a molecule-based strategy that focused on imaging probes.

  8. Application of split field technique with 42 MeV betatron bremsstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Spurny, V; Caha, A; Krystof, V; Ott, O [Vyzkumny Ustav Klinicke a Experimentalni Onkologie, Brno (Czechoslovakia)

    1977-03-01

    The split field technique of external irradiation in oncology is described. A 120x28x79 mm lead shielding block was manufactured for a bremsstrahlung radiation with 42 MeV maximum energy. The block was secured to a holder whose design corresponded to tube holders. The block shielding capacity was tested by phantom measurements at a focal depth of 130 mm and at a distance of the block from the phantom surface of 990 mm. For the 42 MeV bremsstrahlung the reduction was found to be 15% of the focal dose in the 20x20 cm/sup 2/ field in the focal depth at a distance of 1200 mm from the bremsstrahlung focus. Dose distribution was established by using two opposite fields in combination as well as by the courses of the maximum and the relative doses in variation with the female patient's antero-posterior diameter. The results show that the split field technique permits a short adjustment time, is simple and reproducible. As against cobalt application, the beam characteristics permit reducing the integral dose.

  9. Multi-focal Vision and Gaze Control Improve Navigation Performance

    Directory of Open Access Journals (Sweden)

    Kolja Kuehnlenz

    2008-11-01

    Full Text Available Multi-focal vision systems comprise cameras with various fields of view and measurement accuracies. This article presents a multi-focal approach to localization and mapping of mobile robots with active vision. An implementation of the novel concept is done considering a humanoid robot navigation scenario where the robot is visually guided through a structured environment with several landmarks. Various embodiments of multi-focal vision systems are investigated and the impact on navigation performance is evaluated in comparison to a conventional mono-focal stereo set-up. The comparative studies clearly show the benefits of multi-focal vision for mobile robot navigation: flexibility to assign the different available sensors optimally in each situation, enhancement of the visible field, higher localization accuracy, and, thus, better task performance, i.e. path following behavior of the mobile robot. It is shown that multi-focal vision may strongly improve navigation performance.

  10. Flotillins Regulate Focal Adhesions by Interacting with α-Actinin and by Influencing the Activation of Focal Adhesion Kinase

    Directory of Open Access Journals (Sweden)

    Antje Banning

    2018-04-01

    Full Text Available Cell–matrix adhesion and cell migration are physiologically important processes that also play a major role in cancer spreading. In cultured cells, matrix adhesion depends on integrin-containing contacts such as focal adhesions. Flotillin-1 and flotillin-2 are frequently overexpressed in cancers and are associated with poor survival. Our previous studies have revealed a role for flotillin-2 in cell–matrix adhesion and in the regulation of the actin cytoskeleton. We here show that flotillins are important for cell migration in a wound healing assay and influence the morphology and dynamics of focal adhesions. Furthermore, anchorage-independent growth in soft agar is enhanced by flotillins. In the absence of flotillins, especially flotillin-2, phosphorylation of focal adhesion kinase and extracellularly regulated kinase is diminished. Flotillins interact with α-actinin, a major regulator of focal adhesion dynamics. These findings are important for understanding the molecular mechanisms of how flotillin overexpression in cancers may affect cell migration and, especially, enhance metastasis formation.

  11. Survey on depth distribution of underground structures for consideration of human intrusion into TRU waste repository

    International Nuclear Information System (INIS)

    Sakamoto, Yoshiaki; Senoo, Muneaki; Sugimoto, Junichiro; Ohishi, Kiyotaka; Okishio, Masanori; Shimizu, Haruo.

    1996-01-01

    Depth distributions of some kinds of underground structure in Japan have been investigated to get an information about suitable depth of underground repository for TRU waste that is arising from reprocessing and MOX fuel fabrication plants. The underground structures investigated in this work were foundation pile of multistoried building, that of elevated expressway, that of JR shinkansen railway, tunnel of subway and wells. The major depth distribution of the underground structures except for the wells was in range from 30 to 50m, and their maximum depth was less than 100m. On the other hand, the 99% of wells was less than 300m in depth. Maximum depth of the other underground structures has been also investigated for a survey of the utilization of underground by artificial structures in Japan. (author)

  12. Continuously variable focal length lens

    Science.gov (United States)

    Adams, Bernhard W; Chollet, Matthieu C

    2013-12-17

    A material preferably in crystal form having a low atomic number such as beryllium (Z=4) provides for the focusing of x-rays in a continuously variable manner. The material is provided with plural spaced curvilinear, optically matched slots and/or recesses through which an x-ray beam is directed. The focal length of the material may be decreased or increased by increasing or decreasing, respectively, the number of slots (or recesses) through which the x-ray beam is directed, while fine tuning of the focal length is accomplished by rotation of the material so as to change the path length of the x-ray beam through the aligned cylindrical slows. X-ray analysis of a fixed point in a solid material may be performed by scanning the energy of the x-ray beam while rotating the material to maintain the beam's focal point at a fixed point in the specimen undergoing analysis.

  13. Characterization and functional correlation of multiple imaging modalities with focal choroidal excavation

    Directory of Open Access Journals (Sweden)

    Yun-Chen Chen

    2018-05-01

    Full Text Available Background: To investigate the clinical manifestations and imaging features of near-infrared autofluorescence (NIA, infrared reflectance (IR, fundus autofluorescence (FAF, indocyanine green angiography (ICGA and fluorescein angiography (FAG in the detection of patients with focal choroidal excavation (FCE identified by cross-sectional spectral-domain optical coherence tomography (SD-OCT. Methods: This retrospective cross-sectional study included 12 eyes of 10 Taiwanese patients with FCE diagnosed by SD-OCT. The areas and depths of FCE in serial cross-sectional and en-face OCT were compared in different imaging modalities. NIA, IR, FAF, ICGA and FAG images were obtained. Best corrected visual acuity, subjective distortion area in the Amsler grid and history of maculopathies were also recorded. Results: In areas where the choroid started to excavate as shown in SD-OCT, hypo-autofluorescence in NIA was noted. The area of hypo-fluorescence in NIA of all the FCE lesions showed good correlation with the size. The area of FCE was associated with complications such as choroidal neovascularization and central serous chorioretinopathy (p = 0.014, d.f = 1 and the volume (NIA area × Depth measured by SD-OCT × 1/3 was associated with subjective distortion strongly (p = 0.051, Spearman's correlation = 0.600. Conclusion: Among all image modalities, NIA was the most sensitive tool in area measurement of FCE and peripheral lesion detection. Also, the volume of FCE was associated with subjective distortion and the area was related to complications. Recording the area and volume of FCE could play an important role in monitoring complications. Keywords: Choroid-retina disease, Focal choroidal excavation, Near-infrared autofluorescence, Spectral-domain optical coherence tomography

  14. Depths of Intraplate Indian Ocean Earthquakes from Waveform Modeling

    Science.gov (United States)

    Baca, A. J.; Polet, J.

    2014-12-01

    The Indian Ocean is a region of complex tectonics and anomalous seismicity. The ocean floor in this region exhibits many bathymetric features, most notably the multiple inactive fracture zones within the Wharton Basin and the Ninetyeast Ridge. The 11 April 2012 MW 8.7 and 8.2 strike-slip events that took place in this area are unique because their rupture appears to have extended to a depth where brittle failure, and thus seismic activity, was considered to be impossible. We analyze multiple intraplate earthquakes that have occurred throughout the Indian Ocean to better constrain their focal depths in order to enhance our understanding of how deep intraplate events are occurring and more importantly determine if the ruptures are originating within a ductile regime. Selected events are located within the Indian Ocean away from major plate boundaries. A majority are within the deforming Indo-Australian tectonic plate. Events primarily display thrust mechanisms with some strike-slip or a combination of the two. All events are between MW5.5-6.5. Event selections were handled this way in order to facilitate the analysis of teleseismic waveforms using a point source approximation. From these criteria we gathered a suite of 15 intraplate events. Synthetic seismograms of direct P-waves and depth phases are computed using a 1-D propagator matrix approach and compared with global teleseismic waveform data to determine a best depth for each event. To generate our synthetic seismograms we utilized the CRUST1.0 software, a global crustal model that generates velocity values at the hypocenter of our events. Our waveform analysis results reveal that our depths diverge from the Global Centroid Moment Tensor (GCMT) depths, which underestimate our deep lithosphere events and overestimate our shallow depths by as much as 17 km. We determined a depth of 45km for our deepest event. We will show a comparison of our final earthquake depths with the lithospheric thickness based on

  15. Design of a nanopatterned long focal-length planar focusing collector for concentrated solar power

    Science.gov (United States)

    Ding, Qing; Choubal, Aakash; Toussaint, Kimani C.

    2017-02-01

    Concentrated solar power (CSP) facilities heavily utilize parabolic troughs to collect and concentrate sunlight onto receivers that deliver solar thermal energy to heat engines for generating electricity. However, parabolic troughs are bulky and heavy and result in a large capital investment for CSP plants, thereby making it difficult for CSP technology to be competitive with photovoltaics. We present the design of a planar focusing collector (PFC) with focal length beyond the micron scale. The PFC design is based on the use of a nanostructured silver surface for linearly polarized singlewavelength light. The designed PFC consists of metallic nanogrooves on a dielectric substrate. The geometric properties, namely the width and depth, of a single-unit nanogroove allows for full control of the optical phase at desired spatial coordinates along the nanogroove short-axis for a single wavelength. Moreover, we show numerically that such phase control can be used to construct a phase front that mimics that of a cylindrical lens. In addition, we determine the concentration ratio by comparing the width of our PFC design to the cross-sectional width of its focal spot. We also determine the conversion efficiency at long focal lengths by evaluating the ratio of the collected optical power to the incoming optical power. Finally, we examine the focusing behavior across multiple wavelengths and angles of incidence. Our work shows how nano-optics and plasmonics could contribute to this important area of CSP technology.

  16. CT appearance of focal fatty infiltration of the liver

    International Nuclear Information System (INIS)

    Halvorsen, R.A.; Korobkin, M.; Ram, P.C.; Thompson, W.M.

    1982-01-01

    Focal fatty infiltration of the liver is an entity that may be confused with liver metastasis on computed tomography (CT). The imaging results and medical records of 16 patients with CT appearance suggestive of focal fatty liver were reviewed, three of whom had the simultaneous presence of metastitic liver disease. Focal fatty liver often has a distinctive appearance with CT, usually with a nonspherical shape, absence of mass effect, and density close to water. Liver metastases are usually round or oval, and unless cystic or necrotic, they have CT attenuation values closer to normal liver parenchyma than water. A radionuclide liver scan almost always resolves any confusion about the differential diagnosis of focal fatty liver: a well defined focus of photon deficiency is due to neoplasm rather than focal fatty infiltration. Sonography sometimes helps to confirm the CT impression, but may be misleading if the diagnosis of focal or diffuse fatty infiltration is not suspected before the examination

  17. The study of the focal trough in panoramic radiograph

    International Nuclear Information System (INIS)

    Park, C. S.; Kim, H. P.

    1982-01-01

    In the study of the focal trough of panoramic radiograph, using the Moritta company Panex EC a series of 48 exposures were taken with the 6-18 brass pins placed in the holes of the plastic model plate, then evaluated by 4 observers. The author analyzed the focal trough defined by the sharpness criteria and calculated the vertical and horizontal magnification range in the corrected focal trough. The results were as follows; 1. Continuous focal trough was not defined in the anterior region using a very high degree of sharpness. 2. As degree of sharpness used in the analysis became less, focal trough was continuous in the anterior and posterior regions, symmetrized bilaterally, and the widths of the focal trough increased more in the posterior region. 3. As sharpness criteria were reduced, the percentage range of image magnification increased in both vertical and horizontal magnification, and especially the percentage range of horizontal magnification was greater than that of vertical magnification.

  18. Focal myositis: A review.

    Science.gov (United States)

    Devic, P; Gallay, L; Streichenberger, N; Petiot, P

    2016-11-01

    Amongst the heterogeneous group of inflammatory myopathies, focal myositis stands as a rare and benign dysimmune disease. Although it can be associated with root and/or nerve lesions, traumatic muscle lesions and autoimmune diseases, its triggering factors remain poorly understood. Defined as an isolated inflammatory pseudotumour usually restricted to one skeletal muscle, clinical presentation of focal myositis is that of a rapidly growing solitary mass within a single muscle, usually in the lower limbs. Electromyography shows spontaneous activity associated with a myopathic pattern. MRI reveals a contrast enhanced enlarged muscle appearing hyper-intense on FAT-SAT T2 weighted images. Adjacent structures are spared and there are no calcifications. Serum creatine kinase (CK) levels are usually moderately augmented and biological markers of systemic inflammation are absent in most cases. Pathological histological features include marked variation in fibre size, inflammatory infiltrates mostly composed of T CD4+ lymphocytes and macrophages, degenerating/regenerating fibres and interstitial fibrosis. Differential diagnoses are numerous and include myositis of other origin with focal onset. Steroid treatment should be reserved for patients who present with major pain, nerve lesions, associated autoimmune disease, or elevated C reactive protein or CK. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Prenatal sonographic diagnosis of focal musculoskeletal anomalies

    International Nuclear Information System (INIS)

    Ryu, Jung-Kyu; Cho, Jeong-Yeon; Choi, Jong-Sun

    2003-01-01

    Focal musculoskeletal anomalies vary, and can manifest as part of a syndrome or be accompanied by numerous other conditions such as genetic disorders, karyotype abnormalities, central nervous system anomalies and other skeletal anomalies, lsolated focal musculoskeletal anomaly does, however, also occur; its early prenatal diagnosis is important in deciding prenatal care, and also helps in counseling parents about the postnatal effects of numerous possible associated anomalies. We have encountered 50 cases involving focal musculoskeletal anomalies, including total limb dysplasia [radial ray abnormality (n=3), mesomelic dysplasia (n=1)]; anomalies of the hand [polydactyly (n=8), syndactyly (n=3), ectrodactyly (n=1), clinodactyly (n=6), clenched hand (n=5)]; anomalies of the foot [clubfoot (n=10), rockerbottom foot (n=5), sandal gap deformity (n=1), curly toe (n=2)]; amniotic band syndrome (n=3); and anomalies of the focal spine [block vertebra (n=1), hemivertebra (n=1)]. Among these 50 cases, five [polydactyly (n=1), syndactyly (n=2) and curly toe (n=2) were confirmed by postnatal physical evaluation, two (focal spine anomalies) were diagnosed after postnatal radiologic examination, and the remaining 43 were proven at autopsy. For each condition, we describe the prenatal sonographic findings, and include a brief review

  20. Prenatal sonographic diagnosis of focal musculoskeletal anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jung-Kyu; Cho, Jeong-Yeon; Choi, Jong-Sun [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2003-12-15

    Focal musculoskeletal anomalies vary, and can manifest as part of a syndrome or be accompanied by numerous other conditions such as genetic disorders, karyotype abnormalities, central nervous system anomalies and other skeletal anomalies, lsolated focal musculoskeletal anomaly does, however, also occur; its early prenatal diagnosis is important in deciding prenatal care, and also helps in counseling parents about the postnatal effects of numerous possible associated anomalies. We have encountered 50 cases involving focal musculoskeletal anomalies, including total limb dysplasia [radial ray abnormality (n=3), mesomelic dysplasia (n=1)]; anomalies of the hand [polydactyly (n=8), syndactyly (n=3), ectrodactyly (n=1), clinodactyly (n=6), clenched hand (n=5)]; anomalies of the foot [clubfoot (n=10), rockerbottom foot (n=5), sandal gap deformity (n=1), curly toe (n=2)]; amniotic band syndrome (n=3); and anomalies of the focal spine [block vertebra (n=1), hemivertebra (n=1)]. Among these 50 cases, five [polydactyly (n=1), syndactyly (n=2) and curly toe (n=2) were confirmed by postnatal physical evaluation, two (focal spine anomalies) were diagnosed after postnatal radiologic examination, and the remaining 43 were proven at autopsy. For each condition, we describe the prenatal sonographic findings, and include a brief review.

  1. Bilateral differences in peak force, power, and maximum plie depth during multiple grande jetes

    NARCIS (Netherlands)

    Wyon, M.; Harris, J.; Brown, D.D.; Clark, F.

    2013-01-01

    A lateral bias has been previously reported in dance training. The aim of this study was to investigate whether there are any bilateral differences in peak forces, power, and maximum knee flexion during a sequence of three grand jetes and how they relate to leg dominance. A randomised observational

  2. Recent Intermediate Depth Earthquakes in El Salvador, Central Mexico, Cascadia and South-West Japan

    Science.gov (United States)

    Lemoine, A.; Gardi, A.; Gutscher, M.; Madariaga, R.

    2001-12-01

    We studied occurence and source parameters of several recent intermediate depth earthquakes. We concentrated on the Mw=7.7 salvadorian earthquake which took place on January 13, 2001. It was a good example of the high seismic risk associated to such kind of events which occur closer to the coast than the interplate thrust events. The Salvadorian earthquake was an intermediate depth downdip extensional event which occured inside the downgoing Cocos plate, next to the downdip flexure where the dip increases sharply before the slab sinks more steeply. This location corresponds closely to the position of the Mw=5.7 1996 and Mw=7.3 1982 downdip extensional events. Several recent intermediate depth earthquakes occured in subduction zones exhibiting a ``flat slab'' geometry with three distinct flexural bends where flexural stress may be enhanced. The Mw=6.7 Geiyo event showed a downdip extensional mechanism with N-S striking nodal planes. This trend was highly oblique to the trench (Nankai Trough), yet consistent with westward steepening at the SW lateral termination of the SW Japan flat slab. The Mw=6.8 Olympia earthquake in the Cascadia subduction zone occured at the downdip termination of the Juan de Fuca slab, where plate dip increases from about 5o to over 30o. The N-S orientation of the focal planes, parallel to the trench indicated downdip extension. The location at the downdip flexure corresponds closely to the estimated positions of the 1949 M7.1 Olympia and 1965 M6.5 Seattle-Tacoma events. Between 1994 and 1999, in Central Mexico, an unusually high intermediate depth seismicity occured where several authors proposed a flat geometry for the Cocos plate. Seven events of magnitude between Mw=5.9 and Mw=7.1 occured. Three of them were downdip compressional and four where down-dip extensional. We can explain these earthquakes by flexural stresses at down-dip and lateral terminations of the supposed flat segment. Even if intermediate depth earthquakes occurence could

  3. Seismicity, fault plane solutions, depth of faulting, and active tectonics of the Andes of Peru, Ecuador, and southern Colombia

    Science.gov (United States)

    Suarez, G.; Molnar, P.; Burchfiel, B. C.

    1983-01-01

    The long-period P waveforms observed for 17 earthquakes in the Peruvian Andes during 1963-1976 are compared with synthetic waveforms to obtain fault-plane solutions and focal depths. The morphological units of the Peruvian Andes are characterized: coastal plains, Cordillera Occidental, altiplano and central high plateau, Cordillera Oriental, and sub-Andes. The data base and analysis methodology are discussed, and the results are presented in tables, diagrams, graphs, maps, and photographs illustrating typical formations. Most of the earthquakes are shown to occur in the transition zone from the sub-Andes to the Cordillera Oriental under formations of about 1 km elevation at focal depths of 10-38 km. It is suggested that the sub-Andean earthquakes reflect hinterland deformation of a detached fold and thrust belt, perhaps like that which occurred in parts of the Canadian Rockies. From the total crustal shortening evident in Andean morphology and the shortening rate of the recent earthquakes it is estimated that the topography and crustal root of the Andes have been formed during the last 90-135 Myr.

  4. Focal Atrichia: A Diagnostic Clue in Female Pattern Hair Loss.

    Science.gov (United States)

    Olsen, Elise A; Whiting, David A

    2017-10-07

    Focal atrichia is a common clinical finding in female pattern hair loss whose specificity and histologic findings need further clarification. To determine the frequency of focal atrichia in various types of hair loss and its histologic characteristics in female pattern hair loss. Part 1: Review of 250 consecutive female patients seen with hair loss for the presence of focal atrichia and Part 2: paired biopsies of haired areas vs focal atrichia in 18 subjects with female pattern hair loss RESULTS: Focal atrichia was seen in 46/104 (44%) of women with female pattern hair loss, including 67% of late onset vs 15% of early onset, compared to 3/146 (2%) of those with other hair disorders Biopsy findings of focal atrichia in female pattern hair loss showed primarily a more progressive miniaturization process than that of haired areas of the scalp. Some women with female pattern hair loss may have had concomitant chronic telogen effluvium CONCLUSIONS: When present, focal atrichia is a clinical clue to the diagnosis of female pattern hair loss, particularly late onset subtype. Copyright © 2017. Published by Elsevier Inc.

  5. Testing of focal plane arrays

    International Nuclear Information System (INIS)

    Merriam, J.D.

    1988-01-01

    Problems associated with the testing of focal plane arrays are briefly examined with reference to the instrumentation and measurement procedures. In particular, the approach and instrumentation used as the Naval Ocean Systems Center is presented. Most of the measurements are made with flooded illumination on the focal plane array. The array is treated as an ensemble of individual pixels, data being taken on each pixel and array averages and standard deviations computed for the entire array. Data maps are generated, showing the pixel data in the proper spatial position on the array and the array statistics

  6. No support for Heincke's law in hagfish (Myxinidae): lack of an association between body size and the depth of species occurrence.

    Science.gov (United States)

    Schumacher, E L; Owens, B D; Uyeno, T A; Clark, A J; Reece, J S

    2017-08-01

    This study tests for interspecific evidence of Heincke's law among hagfishes and advances the field of research on body size and depth of occurrence in fishes by including a phylogenetic correction and by examining depth in four ways: maximum depth, minimum depth, mean depth of recorded specimens and the average of maximum and minimum depths of occurrence. Results yield no evidence for Heincke's law in hagfishes, no phylogenetic signal for the depth at which species occur, but moderate to weak phylogenetic signal for body size, suggesting that phylogeny may play a role in determining body size in this group. © 2017 The Fisheries Society of the British Isles.

  7. Influence of the focal point position on the properties of a laser-produced plasma

    International Nuclear Information System (INIS)

    Kasperczuk, A.; Pisarczyk, T.; Badziak, J.; Miklaszewski, R.; Parys, P.; Rosinski, M.; Wolowski, J.; Stenz, CH.; Ullschmied, J.; Krousky, E.; Masek, K.; Pfeifer, M.; Rohlena, K.; Skala, J.; Pisarczyk, P.

    2007-01-01

    This paper deals with investigations of the influence of the focusing lens focal point position on the properties of a plasma produced by a defocused laser beam. The experiment was carried out at the Prague Asterix Laser System iodine laser [K. Jungwirth, A. Cejnarova, L. Juha, B. Kralikova, J. Krasa, E. Krousky, P. Krupickova, L. Laska, K. Masek, T. Mocek, M. Pfeifer, A. Prag, O. Renner, K. Rohlena, B. Rus, J. Skala, P. Straka, and J. Ullschmied, Phys. Plasmas 8, 2495 (2001)] by using the third harmonic of laser radiation (λ=0.438 μm), laser energy of 70 J, pulse duration of 250 ps (full width at half-maximum), and beam spot radii of 250 and 400 μm. Cu and Ta were chosen as target materials. The experimental data were obtained by means of a three-frame interferometric system, ion collectors, and crater replica techniques. The reported results allow formulating an important hypothesis that the laser-produced plasma modifies strongly the laser intensity distribution. It is shown how such a modification depends on the relative position and distance of the focal point to the target surface. Of particular importance is whether the focal point is located inside or in front of the target. The irradiation geometry is crucial for the possibility of generating plasma jets by laser radiation. Well-formed jet-like plasma structures can be created if an initially homogeneous laser intensity distribution is transformed in the plasma to an annular one

  8. MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system

    Science.gov (United States)

    Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron

    2014-03-01

    Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.

  9. Focal Length Affects Depicted Shape and Perception of Facial Images.

    Directory of Open Access Journals (Sweden)

    Vít Třebický

    Full Text Available Static photographs are currently the most often employed stimuli in research on social perception. The method of photograph acquisition might affect the depicted subject's facial appearance and thus also the impression of such stimuli. An important factor influencing the resulting photograph is focal length, as different focal lengths produce various levels of image distortion. Here we tested whether different focal lengths (50, 85, 105 mm affect depicted shape and perception of female and male faces. We collected three portrait photographs of 45 (22 females, 23 males participants under standardized conditions and camera setting varying only in the focal length. Subsequently, the three photographs from each individual were shown on screen in a randomized order using a 3-alternative forced-choice paradigm. The images were judged for attractiveness, dominance, and femininity/masculinity by 369 raters (193 females, 176 males. Facial width-to-height ratio (fWHR was measured from each photograph and overall facial shape was analysed employing geometric morphometric methods (GMM. Our results showed that photographs taken with 50 mm focal length were rated as significantly less feminine/masculine, attractive, and dominant compared to the images taken with longer focal lengths. Further, shorter focal lengths produced faces with smaller fWHR. Subsequent GMM revealed focal length significantly affected overall facial shape of the photographed subjects. Thus methodology of photograph acquisition, focal length in this case, can significantly affect results of studies using photographic stimuli perhaps due to different levels of perspective distortion that influence shapes and proportions of morphological traits.

  10. Prenatal sonographic diagnosis of focal musculoskeletal anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jung Kyu; Cho, Jeong Yeon; Lee, Young Ho; Kim, Ei Jeong; Chun, Yi Kyeong [Samsung Cheil Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2002-09-15

    Focal musculoskeletal anomalies are various and may be an isolated finding or may be found in conjunction with numerous associations, including genetic syndromes, Karyotype abnormals, central nervous system anomalies and other general musculoskeletal disorders. Early prenatal diagnosis of these focal musculoskeletal anomalies nor only affects prenatal care and postnatal outcome but also helps in approaching other numerous associated anomalies.

  11. Prenatal sonographic diagnosis of focal musculoskeletal anomalies

    International Nuclear Information System (INIS)

    Ryu, Jung Kyu; Cho, Jeong Yeon; Lee, Young Ho; Kim, Ei Jeong; Chun, Yi Kyeong

    2002-01-01

    Focal musculoskeletal anomalies are various and may be an isolated finding or may be found in conjunction with numerous associations, including genetic syndromes, Karyotype abnormals, central nervous system anomalies and other general musculoskeletal disorders. Early prenatal diagnosis of these focal musculoskeletal anomalies nor only affects prenatal care and postnatal outcome but also helps in approaching other numerous associated anomalies.

  12. FOCAL CORTICAL DYSPLASIAS: CLINICAL AND ELECTRO-NEUROIMAGING CHARACTERISTICS

    Directory of Open Access Journals (Sweden)

    K. Yu. Mukhin

    2016-01-01

    Full Text Available In spite of a notable advance made in epileptology, resistant epilepsies account for approximately 30 % of all forms of epilepsy particularly in patients with focal seizures. One of the main causes of therapy-resistant focal epilepsies is focal cortical dysplasias (FCD. This term was first introduced by D. Taylor et al. in 1971. FCD belongs to abnormal cortical development. Among all abnormalities of cortical development, FCD in surgically treated children amounts to 75 %. FCD is the most common cause of resistant epilepsy in children and the most frequent reason for diagnosing cryptogenic focal epilepsy with intractable seizures. The author gives a detailed literature review dedicated to FCD as a cause of resistant epilepsy, including the classification and histologic characteristics of FCD, its clinical manifestations and prognosis, and approaches to medical and surgical treatments. 

  13. Multispectral linear array (MLA) focal plane mechanical and thermal design

    Science.gov (United States)

    Mitchell, A. S.; Kaminski, E. F.

    1982-01-01

    The mechanical and thermal design of an integrated focal plane subsystem of a Multispectral Linear Array (MLA) instrument is discussed in terms of focal-plane alignment, thermoelastic performance, and thermal requirements. The modular construction and thermal control of the focal plane array are discussed.

  14. The semiology of febrile seizures: Focal features are frequent.

    Science.gov (United States)

    Takasu, Michihiko; Kubota, Tetsuo; Tsuji, Takeshi; Kurahashi, Hirokazu; Numoto, Shingo; Watanabe, Kazuyoshi; Okumura, Akihisa

    2017-08-01

    To clarify the semiology of febrile seizures (FS) and to determine the frequency of FS with symptoms suggestive of focal onset. FS symptoms in children were reported within 24h of seizure onset by the parents using a structured questionnaire consisting principally of closed-ended questions. We focused on events at seizure commencement, including changes in behavior and facial expression, and ocular and oral symptoms. We also investigated the autonomic and motor symptoms developing during seizures. The presence or absence of focal and limbic features was determined for each patient. The associations of certain focal and limbic features with patient characteristics were assessed. Information was obtained on FS in 106 children. Various events were recorded at seizure commencement. Behavioral changes were observed in 35 children, changes in facial expression in 53, ocular symptoms in 78, and oral symptoms in 90. In terms of events during seizures, autonomic symptoms were recognized in 78, and convulsive motor symptoms were recognized in 68 children. Focal features were evident in 81 children; 38 children had two or more such features. Limbic features were observed in 44 children, 9 of whom had two or more such features. There was no significant relationship between any patient characteristic and the numbers of focal or limbic features. The semiology of FS varied widely among children, and symptoms suggestive of focal onset were frequent. FS of focal onset may be more common than is generally thought. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Electric field strength and focality in electroconvulsive therapy and magnetic seizure therapy: a finite element simulation study

    Science.gov (United States)

    Deng, Zhi-De; Lisanby, Sarah H.; Peterchev, Angel V.

    2011-02-01

    We present the first computational study comparing the electric field induced by various electroconvulsive therapy (ECT) and magnetic seizure therapy (MST) paradigms. Four ECT electrode configurations (bilateral, bifrontal, right unilateral, and focal electrically administered seizure therapy) and three MST coil configurations (circular, cap, and double cone) were modeled. The model incorporated a modality-specific neural activation threshold. ECT (0.3 ms pulse width) and MST induced the maximum electric field of 2.1-2.5 V cm-1 and 1.1-2.2 V cm-1 in the brain, corresponding to 6.2-7.2 times and 1.2-2.3 times the neural activation threshold, respectively. The MST electric field is more confined to the superficial cortex compared to ECT. The brain volume stimulated was much larger with ECT (up to 100%) than with MST (up to 8.2%). MST with the double-cone coil was the most focal, and bilateral ECT was the least focal. Our results suggest a possible biophysical explanation of the reduced side effects of MST compared to ECT. Our results also indicate that the conventional ECT pulse amplitude (800-900 mA) is much higher than necessary for seizure induction. Reducing the ECT pulse amplitude should be explored as a potential means of diminishing side effects.

  16. The flexible engagement of monitoring processes in non-focal and focal prospective memory tasks with salient cues.

    Science.gov (United States)

    Hefer, Carmen; Cohen, Anna-Lisa; Jaudas, Alexander; Dreisbach, Gesine

    2017-09-01

    Prospective memory (PM) refers to the ability to remember to perform a delayed intention. Here, we aimed to investigate the ability to suspend such an intention and thus to confirm previous findings (Cohen, Gordon, Jaudas, Hefer, & Dreisbach, 2016) demonstrating the ability to flexibly engage in monitoring processes. In the current study, we presented a perceptually salient PM cue (bold and red) to rule out that previous findings were limited to non-salient and, thus, easy to ignore PM cues. Moreover, we used both a non-focal (Experiment 1) and a focal PM (Experiment 2) cue. In both Experiments, three groups of participants performed an Eriksen flanker task as an ongoing task with an embedded PM task (they had to remember to press the F1 key if a pre-specified cue appeared). Participants were assigned to either a control condition (performed solely the flanker task), a standard PM condition (performed the flanker task along with the PM task), or a PM delayed condition (performed the flanker task but were instructed to postpone their PM task intention). The results of Experiment 1 with the non-focal PM cue closely replicated those of Cohen et al. (2016) and confirmed that participants were able to successfully postpone the PM cue intention without additional costs even when the PM cue was a perceptually salient one. However, when the PM cue was focal (Experiment 2), it was much more difficult for participants to ignore it as evidenced by commission errors and slower latencies on PM cue trials. In sum, results showed that the focality of the PM cue plays a more crucial role in the flexibility of the monitoring process whereas the saliency of the PM cue does not. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Performance evaluation of a 64-slice CT system with z-flying focal spot.

    Science.gov (United States)

    Flohr, T; Stierstorfer, K; Raupach, R; Ulzheimer, S; Bruder, H

    2004-12-01

    The meanwhile established generation of 16-slice CT systems enables routine sub-millimeter imaging at short breath-hold times. Clinical progress in the development of multidetector row CT (MDCT) technology beyond 16 slices can more likely be expected from further improvement in spatial and temporal resolution rather than from a mere increase in the speed of volume coverage. We present an evaluation of a recently introduced 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany), which uses a periodic motion of the focal spot in longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. This technique acquires 64 overlapping 0.6 mm slices per rotation. The sampling scheme corresponds to that of a 64 x 0.3 mm detector, with the goal of improved longitudinal resolution and reduced spiral artifacts. After an introduction to the detector design, we discuss the basics of z-flying focal spot technology (z-Sharp). We present phantom and specimen scans for performance evaluation. The measured full width at half maximum (FWHM) of the thinnest spiral slice is 0.65 mm. All spiral slice widths are almost independent of the pitch, with deviations of less than 0.1 mm from the nominal value. Using a high-resolution bar pattern phantom (CATPHAN, Phantom Laboratories, Salem, NY), the longitudinal resolution can be demonstrated to be up to 15 lp/cm at the isocenter independent of the pitch, corresponding to a bar diameter of 0.33 mm. Longitudinal resolution is only slightly degraded for off-center locations. At a distance of 100 mm from the isocenter, 14 lp/cm can be resolved in the z-direction, corresponding to a bar diameter of 0.36 mm. Spiral "windmill" artifacts presenting as hyper- and hypodense structures around osseous edges are effectively reduced by the z-flying focal spot technique. Cardiac scanning benefits from the short gantry rotation time of 0.33 s, providing up to 83 ms temporal resolution with 2-segment ECG

  18. Evaluation of canister weld flaw depth for concrete storage cask

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Tae Chul; Cho, Chun Hyung [Korea Radioactive Waste Agency, Daejeon (Korea, Republic of); Jung, Sung Hun; Lee, Young Oh; Jung, In Su [Korea Nuclear Engineering and Service Corp, Daejeon (Korea, Republic of)

    2017-03-15

    Domestically developed concrete storage casks include an internal canister to maintain the confinement integrity of radioactive materials. In this study, we analyzed the depth of flaws caused by loads that propagate canister weld cracks under normal, off-normal and accident conditions, and evaluated the maximum allowable weld flaw depth needed to secure the structural integrity of the canister weld and to reduce the welding time of the internal canister lid of the concrete storage cask. Structural analyses for normal, off-normal and accident conditions were performed using the general-purpose finite element analysis program ABAQUS; the allowable flaw depth was assessed according to ASME B and PV Code Section XI. Evaluation results revealed an allowable canister weld flaw depth of 18.75 mm for the concrete storage cask, which satisfies the critical flaw depth recommended in NUREG-1536.

  19. Focal necrotizing pneumonia is a distinct entity from lung abscess.

    Science.gov (United States)

    Seo, Hyewon; Cha, Seung-Ick; Shin, Kyung-Min; Lim, Jaekwang; Yoo, Seung-Soo; Lee, Jaehee; Lee, Shin-Yup; Kim, Chang-Ho; Park, Jae-Yong

    2013-10-01

    'Focal necrotizing pneumonia' was defined as a localized type of necrotizing pneumonia characterized by a single or few cavities of low density without rim enhancement on computed tomography (CT) scan. The purpose of this study was to investigate the clinical features and course of patients with focal necrotizing pneumonia, thereby elucidating its clinical relevance. The present study was conducted retrospectively in patients who had been interpreted as having lung abscess or necrotizing pneumonia on CT scan. Clinical and radiological characteristics were compared between the focal necrotizing pneumonia and lung abscess groups. Overall, 68 patients with focal necrotizing pneumonia (n = 35) or lung abscess (n = 33) were included in the present study. The frequency of risk factors for aspiration was significantly lower in the focal necrotizing group, compared with the lung abscess group (14.3% vs 45.5%, P = 0.005). Compared with lung abscess, focal necrotizing pneumonia was observed more commonly in non-gravity-dependent segments (66% vs 36%, P lung abscess group (31% vs 12%, P = 0.08). However, in terms of treatment outcomes, a similar high rate of success was observed in both groups: 97%, respectively. Compared to lung abscess, focal necrotizing pneumonia occurs more commonly in non-gravity-dependent segments with lower incidence of risk factors for aspiration. Similar to lung abscess, the rate of success for treatment of focal necrotizing pneumonia was high. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  20. Proximal Focal Femoral Deficiency in Ibadan a Developing ...

    African Journals Online (AJOL)

    The cultural aversion to amputation in our environment makes it difficult to employ that option of treatment. Proximal focal femoral deficiency in Ibadan a developing country's perspective and a review of the literature. Keywords: Proximal focal femoral deficiency , congenital malformations , limb malformations , lower limb ...

  1. Slab tears and intermediate-depth seismicity

    Science.gov (United States)

    Meighan, Hallie E.; ten Brink, Uri S.; Pulliam, Jay

    2013-01-01

    Active tectonic regions where plate boundaries transition from subduction to strike slip can take several forms, such as triple junctions, acute, and obtuse corners. Well-documented slab tears that are associated with high rates of intermediate-depth seismicity are considered here: Gibraltar arc, the southern and northern ends of the Lesser Antilles arc, and the northern end of Tonga trench. Seismicity at each of these locations occurs, at times, in the form of swarms or clusters, and various authors have proposed that each marks an active locus of tear propagation. The swarms and clusters start at the top of the slab below the asthenospheric wedge and extend 30–60 km vertically downward within the slab. We propose that these swarms and clusters are generated by fluid-related embrittlement of mantle rocks. Focal mechanisms of these swarms generally fit the shear motion that is thought to be associated with the tearing process.

  2. Shave-off depth profiling: Depth profiling with an absolute depth scale

    International Nuclear Information System (INIS)

    Nojima, M.; Maekawa, A.; Yamamoto, T.; Tomiyasu, B.; Sakamoto, T.; Owari, M.; Nihei, Y.

    2006-01-01

    Shave-off depth profiling provides profiling with an absolute depth scale. This method uses a focused ion beam (FIB) micro-machining process to provide the depth profile. We show that the shave-off depth profile of a particle reflected the spherical shape of the sample and signal intensities had no relationship to the depth. Through the introduction of FIB micro-sampling, the shave-off depth profiling of a dynamic random access memory (DRAM) tip was carried out. The shave-off profile agreed with a blue print from the manufacturing process. Finally, shave-off depth profiling is discussed with respect to resolutions and future directions

  3. Removing defocused objects from single focal plane scans of cytological slides

    Directory of Open Access Journals (Sweden)

    David Friedrich

    2016-01-01

    Full Text Available Background: Virtual microscopy and automated processing of cytological slides are more challenging compared to histological slides. Since cytological slides exhibit a three-dimensional surface and the required microscope objectives with high resolution have a low depth of field, these cannot capture all objects of a single field of view in focus. One solution would be to scan multiple focal planes; however, the increase in processing time and storage requirements are often prohibitive for clinical routine. Materials and Methods: In this paper, we show that it is a reasonable trade-off to scan a single focal plane and automatically reject defocused objects from the analysis. To this end, we have developed machine learning solutions for the automated identification of defocused objects. Our approach includes creating novel features, systematically optimizing their parameters, selecting adequate classifier algorithms, and identifying the correct decision boundary between focused and defocused objects. We validated our approach for computer-assisted DNA image cytometry. Results and Conclusions: We reach an overall sensitivity of 96.08% and a specificity of 99.63% for identifying defocused objects. Applied on ninety cytological slides, the developed classifiers automatically removed 2.50% of the objects acquired during scanning, which otherwise would have interfered the examination. Even if not all objects are acquired in focus, computer-assisted DNA image cytometry still identified more diagnostically or prognostically relevant objects compared to manual DNA image cytometry. At the same time, the workload for the expert is reduced dramatically.

  4. DESI focal plate mechanical integration and cooling

    Science.gov (United States)

    Lambert, A. R.; Besuner, R. W.; Claybaugh, T. M.; Silber, J. H.

    2016-08-01

    The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique[1]. The spectra of 40 million galaxies over 14000 sq. deg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. This paper describes the mechanical integration of the DESI focal plate and the thermal system design. The DESI focal plate is comprised of ten identical petal assemblies. Each petal contains 500 robotic fiber positioners. Each petal is a complete, self-contained unit, independent from the others, with integrated power supply, controllers, fiber routing, and cooling services. The major advantages of this scheme are: (1) supports installation and removal of complete petal assemblies in-situ, without disturbing the others, (2) component production, assembly stations, and test procedures are repeated and parallelizable, (3) a complete, full-scale prototype can be built and tested at an early date, (4) each production petal can be surveyed and tested as a complete unit, prior to integration, from the fiber tip at the focal surface to the fiber slit at the spectrograph. The ten petal assemblies will be installed in a single integration ring, which is mounted to the DESI corrector. The aluminum integration ring attaches to the steel corrector barrel via a flexured steel adapter, isolating the focal plate from differential thermal expansions. The plate scale will be kept stable by conductive cooling of the petal assembly. The guider and wavefront sensors (one per petal) will be convectively cooled by forced flow of air. Heat will be removed from the system at ten liquid-cooled cold plates, one per petal, operating at ambient temperature. The entire focal plate structure is enclosed in an insulating shroud, which serves as a thermal barrier

  5. Focal fatty infiltra- tion and focal fatty sparing of the liver

    African Journals Online (AJOL)

    Enrique

    Department of Radiology. Nelson Mandela School of Health Sciences. Durban. Fig. 1a. Unenhanced CT of the liver in case 1 demonstrates multiple focal low density regions in both lobes of the liver. Region of interest 1 over the fatty left lobe measured 10 HU while region of interest 2 over the right lobe measure 40 HU in.

  6. Extending the fundamental imaging-depth limit of multi-photon microscopy by imaging with photo-activatable fluorophores.

    Science.gov (United States)

    Chen, Zhixing; Wei, Lu; Zhu, Xinxin; Min, Wei

    2012-08-13

    It is highly desirable to be able to optically probe biological activities deep inside live organisms. By employing a spatially confined excitation via a nonlinear transition, multiphoton fluorescence microscopy has become indispensable for imaging scattering samples. However, as the incident laser power drops exponentially with imaging depth due to scattering loss, the out-of-focus fluorescence eventually overwhelms the in-focal signal. The resulting loss of imaging contrast defines a fundamental imaging-depth limit, which cannot be overcome by increasing excitation intensity. Herein we propose to significantly extend this depth limit by multiphoton activation and imaging (MPAI) of photo-activatable fluorophores. The imaging contrast is drastically improved due to the created disparity of bright-dark quantum states in space. We demonstrate this new principle by both analytical theory and experiments on tissue phantoms labeled with synthetic caged fluorescein dye or genetically encodable photoactivatable GFP.

  7. Thermomechanical architecture of the VIS focal plane for Euclid

    International Nuclear Information System (INIS)

    Martignac, Jerome; Carty, Michael; Tourette, Thierry; Bachet, Damien; Berthe, Michel; Augueres, Jean-Louis; Amiaux, Jerome; Fontignie, Jean; Horeau, Benoit; Renaud, Diana

    2014-01-01

    One of the main challenges for current and near future space experiments is the increase of focal plane complexity in terms of amount of pixels. In the frame work of the ESA Euclid mission to be launched in 2020, the Euclid Consortium is developing an extremely large and stable focal plane for the VIS instrument. CEA has developed the thermomechanical architecture of that Focal Plane taking into account all the very stringent performance and mission related requirements. The VIS Focal Plane Assembly integrates 36 CCDs (operated at 150 K) connected to their front end electronics (operated at 280 K) as to obtain one of the largest focal plane (0.6 billion pixels) ever built for space application after the GAIA one. The CCDs are CCD273 type specially designed and provided by the e2v company under ESA contract, front end electronics is studied and provided by MSSL. In this paper we first recall the specific requirements that have driven the overall architecture of the VIS-FPA and especially the solutions proposed to cope with the scientific needs of an extremely stable focal plane, both mechanically and thermally. The mechanical structure based on SiC material used for the cold sub assembly supporting the CCDs is detailed. We describe also the modular architecture concept that we have selected taking into account AIT-AIV and programmatic constraints. (authors)

  8. Diffuse and diffuse-plus-focal uptake in the thyroid gland identified by using FDG-PET. Prevalence of thyroid cancer and Hashimoto's thyroiditis

    International Nuclear Information System (INIS)

    Kurata, Seiji; Ishibashi, Masatoshi; Hiromatsu, Yuji; Kaida, Hayato; Miyake, Ikuyo; Uchida, Masafumi; Hayabuchi, Naofumi

    2007-01-01

    The objective of this study was to investigate and evaluate the prevalence of incidental thyroid diffuse and diffuse-plus-focal fluorine-18 fluorodeoxyglucose (FDG) uptake in healthy subjects who underwent cancer screening on positron emission tomography (PET) scan, and also to evaluate the prevalence of thyroid cancer and Hashimoto's thyroiditis. We carried out a retrospective review of 1626 subjects who underwent PET scanning at our institution. Diffuse uptake was defined as FDG uptake in the whole thyroid gland, whereas diffuse-plus-focal uptake was defined as a thyroid lesion with both diffuse uptake and focal FDG uptake. The maximum standardized uptake value of the thyroid lesions was recorded and reviewed. In each selected subject with positive thyroid FDG uptake, serum thyroid-stimulating hormone, thyroid hormone, and thyroid antibodies were measured. Fine needle aspiration cytology was performed on patients with a definite nodule using ultrasonography. Twenty-nine subjects (1.78%) were identified as having either diffuse FDG uptake (n=25, 1.53%) or diffuse-plus-focal FDG uptake (n=4, 0.24%). All subjects with diffuse FDG uptake were diagnosed as having Hashimoto's thyroiditis. In 1 of the 25 subjects with diffuse FDG uptake and two of the four with diffuse-plus-focal FDG uptake, histopathologic diagnosis showed papillary thyroid carcinoma associated with Hashimoto's thyroiditis. However, PET scan did not detect papillary carcinoma associated with Hashimoto's thyroiditis in one of the three subjects. Our results suggest that although diffuse FDG uptake usually indicates Hashimoto's thyroiditis, the risk of thyroid cancer must be recognized in both diffuse FDG uptake and diffuse-plus-focal FDG uptake on PET scan. (author)

  9. Seismicity, focal mechanisms, and stress distribution in the Tres Virgenes volcanic and geothermal region, Baja California Sur, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Victor; Munguia, Luis [Centro de Investigacion Cientifica y de Educacion Superior de Ensenada (Mexico)

    2006-01-15

    In October 1993 we carried out a seismic monitoring in the Tres Virgenes volcanic region in order to record the background seismicity associated with the volcanic structures, the geothermal field and the tectonic features of the area. Hypocenters for 257 microearthquakes were located in the volcanic edifices and along the northwest right-lateral, strike-slip La Virgen fault. Focal depths range from close to the Earth surface to about 8 km. Shallow depths occur mainly in the volcanic edifices. Deeper seismic events occurred outside the volcanic area. The duration magnitudes of the located microearthquakes range between 1 and 3. The Vp/Vs ratio and the low-Q values estimated suggest heterogeneous material properties in the volcanic structures mainly toward the El Azufre fault and the El Aguajito Caldera, where hydrothermal activity has been reported. The P- and T-axes of focal mechanisms for 90 microearthquakes suggest that the region is under N-S compression and E-W extension, in agreement with the regional tectonic stress field of the NW-SE right-lateral strike-slip transform fault system of the Gulf of California. [Spanish] En octubre de 1993 se llevo a cabo un monitoreo sismico en la region volcanica Las Tres Virgenes con el proposito de registrar la actividad sismica asociada a las estructuras volcanicas, al campo geotermico y a la tectonica local. Se localizaron 257 microsismos con hipocentros en los edificios volcanicos y a lo largo de la falla de rumbo, lateral derecha conocida como falla La Virgen. La profundidad focal de los sismos varia desde los muy cercanos a la superficie de la Tierra hasta los 8 km. Las profundidades someras ocurren principalmente en los edificios volcanicos. Los sismos mas profundos ocurren fuera del area volcanica. La magnitud de duracion de los microsismos localizados varia entre 1 y 3. La razon Vp/Vs y los valores bajos de Q que se estimaron en la zona sugieren un material con propiedades heterogeneas bajo las estructuras

  10. Focal cemento-osseous dysplasia: review and a case report.

    Science.gov (United States)

    Salem, Y M Y; Osman, Y I; Norval, E J G

    2010-10-01

    Focal cemento-osseous dysplasia is a benign fibro-osseous condition that can be seen in dentate and edentulous patients. It is an asymptomatic lesion and needs no treatment; however follow-up is essential due to the possibility that focal cemento-osseous dysplasia can progress to a condition called florid osseous dysplasia that involves multiple sites. A case report is presented here, along with a review of the differential diagnoses considered in order to reach a final diagnosis of focal cemento-osseous dysplasia.

  11. Prediction of lake depth across a 17-state region in the United States

    Science.gov (United States)

    Oliver, Samantha K.; Soranno, Patricia A.; Fergus, C. Emi; Wagner, Tyler; Winslow, Luke A.; Scott, Caren E.; Webster, Katherine E.; Downing, John A.; Stanley, Emily H.

    2016-01-01

    Lake depth is an important characteristic for understanding many lake processes, yet it is unknown for the vast majority of lakes globally. Our objective was to develop a model that predicts lake depth using map-derived metrics of lake and terrestrial geomorphic features. Building on previous models that use local topography to predict lake depth, we hypothesized that regional differences in topography, lake shape, or sedimentation processes could lead to region-specific relationships between lake depth and the mapped features. We therefore used a mixed modeling approach that included region-specific model parameters. We built models using lake and map data from LAGOS, which includes 8164 lakes with maximum depth (Zmax) observations. The model was used to predict depth for all lakes ≥4 ha (n = 42 443) in the study extent. Lake surface area and maximum slope in a 100 m buffer were the best predictors of Zmax. Interactions between surface area and topography occurred at both the local and regional scale; surface area had a larger effect in steep terrain, so large lakes embedded in steep terrain were much deeper than those in flat terrain. Despite a large sample size and inclusion of regional variability, model performance (R2 = 0.29, RMSE = 7.1 m) was similar to other published models. The relative error varied by region, however, highlighting the importance of taking a regional approach to lake depth modeling. Additionally, we provide the largest known collection of observed and predicted lake depth values in the United States.

  12. Fast multifrequency focal beam analysis for 3D seismic acquisition geometry

    NARCIS (Netherlands)

    Wei, W.; Fu, L.; Blacquiere, G.

    2012-01-01

    A method for the efficient computation of multifrequency focal beams for 3D seismic acquisition geometry analysis has been developed. By computing them for all the frequency components of seismic data, single-frequency focal beams can be extended to multifrequency focal beams. However, this

  13. There’s plenty of light at the bottom: statistics of photon penetration depth in random media

    Science.gov (United States)

    Martelli, Fabrizio; Binzoni, Tiziano; Pifferi, Antonio; Spinelli, Lorenzo; Farina, Andrea; Torricelli, Alessandro

    2016-01-01

    We propose a comprehensive statistical approach describing the penetration depth of light in random media. The presented theory exploits the concept of probability density function f(z|ρ, t) for the maximum depth reached by the photons that are eventually re-emitted from the surface of the medium at distance ρ and time t. Analytical formulas for f, for the mean maximum depth 〈zmax〉 and for the mean average depth reached by the detected photons at the surface of a diffusive slab are derived within the framework of the diffusion approximation to the radiative transfer equation, both in the time domain and the continuous wave domain. Validation of the theory by means of comparisons with Monte Carlo simulations is also presented. The results are of interest for many research fields such as biomedical optics, advanced microscopy and disordered photonics. PMID:27256988

  14. Angle dependent focal spot size of a conical X-ray target

    International Nuclear Information System (INIS)

    Saeed Raza, Hamid; Jin Kim, Hyun; Nam Kim, Hyun; Oh Cho, Sung

    2015-01-01

    Misaligned phantoms may severely affect the focal spot calculations. A method is proposed to determine the geometry of the X-ray target and the position of the image radiograph around the X-ray target to get a relatively smaller focal spot size. Results reveal that the focal spot size is not always isotropic around the target but it decreases as the point of observation shifts radially away from the center line of the conical X-ray target. This research will help in producing high quality X-ray images in multi-directions by properly aligning the phantoms and the radiograph tallies. - Highlights: • Misaligned phantoms may severely affect the focal spot calculations. • The aim of this research is to analyze systematically the angle dependent behavior of the focal spot size around a conical shaped X-ray target. • A general purpose Monte Carlo (MCNP5) computer code is used to achieve a relatively small focal spot size. • Angular distribution of the X-ray focal spot size mainly depends on the angular orientation of the phantom and its aligned FIR tally. • This research will help in producing high quality X-ray images in multi-directions

  15. Temperature of the Icelandic crust: Inferred from electrical conductivity, temperature surface gradient, and maximum depth of earthquakes

    Science.gov (United States)

    Björnsson, Axel

    2008-02-01

    Two different models of the structure of the Icelandic crust have been presented. One is the thin-crust model with a 10-15 km thick crust beneath the axial rift zones, with an intermediate layer of partially molten basalt at the base of the crust and on the top of an up-domed asthenosphere. The thick-crust model assumes a 40 km thick and relatively cold crust beneath central Iceland. The most important and crucial parameter to distinguish between these different models is the temperature distribution with depth. Three methods are used to estimate the temperature distribution with depth. First, the surface temperature gradient measured in shallow wells drilled outside geothermal areas. Second, the thickness of the seismogenic zone which is associated with a 750 °C isothermal surface. Third, the depth to a layer with high electrical conductivity which is associated with partially molten basalt with temperature around 1100 °C at the base of the crust. Combination of these data shows that the temperature gradient can be assumed to be nearly linear from the surface down to the base of the crust. These results are strongly in favour of the thin-crust model. The scattered deep seismic reflectors interpreted as Moho in the thick-crust model could be caused by phase transitions or reflections from melt pockets in the mantle.

  16. Position sensitive proportional counters as focal plane detectors

    International Nuclear Information System (INIS)

    Ford, J.L.C. Jr.

    1979-01-01

    The rise time and charge division techniques for position decoding with RC-line proportional counters are reviewed. The advantages that these detectors offer as focal plane counters for nuclear spectroscopy performed with magnetic spectrographs are discussed. The theory of operation of proportional counters as position sensing devices is summarized, as well as practical aspects affecting their application. Factors limiting the position and energy resolutions obtainable with a focal plane proportional counter are evaluated and measured position and energy loss values are presented for comparison. Detector systems capable of the multiparameter measurements required for particle identification, background suppression and ray-tracing are described in order to illustrate the wide applicability of proportional counters within complex focal plane systems. Examples of the use of these counters other than with magnetic spectrographs are given in order to demonstrate their usefulness in not only nuclear physics but also in fields such as solid state physics, biology, and medicine. The influence of the new focal plane detector systems on future magnetic spectrograph designs is discussed. (Auth.)

  17. Benign focal liver lesions: discrimination from malignant mimickers.

    Science.gov (United States)

    Alobaidi, Mohammad; Shirkhoda, Ali

    2004-01-01

    Focal lesions of the liver often have various imaging characteristics which may be interpreted as either benign or malignant. Understanding the underlying pathophysiology of these liver lesions may lead to characteristic imaging manifestations, which direct the radiologist to the diagnosis. Benign lesions include congenital hepatic cyst, autosomal dominant polycystic disease, hemangioma, focal nodular hyperplasia (FNH), hepatic adenoma, inflammatory pseudotumor, peliosis hepatis, focal fatty infiltration, hamartoma, and infectious processes such as hepatic abscess, echinococcal cyst, and candidiasis. Characteristic imaging features, clinical symptoms, and treatment/prognosis will be discussed. Emphasis will be placed on key reliable features of each disease to develop a method of discriminating these lesions from other benign and malignant disorders.

  18. Rooting depth and root depth distribution of Trifolium repens × T. uniflorum interspecific hybrids.

    Science.gov (United States)

    Nichols, S N; Hofmann, R W; Williams, W M; van Koten, C

    2016-05-20

    Traits related to root depth distribution were examined in Trifolium repens × T. uniflorum backcross 1 (BC 1 ) hybrids to determine whether root characteristics of white clover could be improved by interspecific hybridization. Two white clover cultivars, two T. uniflorum accessions and two BC 1 populations were grown in 1 -m deep tubes of sand culture. Maximum rooting depth and root mass distribution were measured at four harvests over time, and root distribution data were fitted with a regression model to provide measures of root system shape. Morphological traits were measured at two depths at harvest 3. Root system shape of the hybrids was more similar to T. uniflorum than to white clover. The hybrids and T. uniflorum had a higher rate of decrease in root mass with depth than white clover, which would result in higher proportions of root mass in the upper profile. Percentage total root mass at 100-200 mm depth was higher for T. uniflorum than white clover, and for Crusader BC 1 than 'Crusader'. Roots of the hybrids and T. uniflorum also penetrated deeper than those of white clover. T. uniflorum had thicker roots at 50-100 mm deep than the other entries, and more of its fine root mass at 400-500 mm. The hybrids and white clover had more of their fine root mass higher in the profile. Consequently, T. uniflorum had a higher root length density at 400-500 mm than most entries, and a smaller decrease in root length density with depth. These results demonstrate that rooting characteristics of white clover can be altered by hybridization with T. uniflorum, potentially improving water and nutrient acquisition and drought resistance. Root traits of T. uniflorum are likely to be adaptations to soil moisture and fertility in its natural environment. © The Author 2016. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Actinic Granuloma with Focal Segmental Glomerulosclerosis

    Directory of Open Access Journals (Sweden)

    Ruedee Phasukthaworn

    2016-02-01

    Full Text Available Actinic granuloma is an uncommon granulomatous disease, characterized by annular erythematous plaque with central clearing predominately located on sun-damaged skin. The pathogenesis is not well understood, ultraviolet radiation is recognized as precipitating factor. We report a case of a 52-year-old woman who presented with asymptomatic annular erythematous plaques on the forehead and both cheeks persisting for 2 years. The clinical presentation and histopathologic findings support the diagnosis of actinic granuloma. During that period of time, she also developed focal segmental glomerulosclerosis. The association between actinic granuloma and focal segmental glomerulosclerosis needs to be clarified by further studies.

  20. Natural-focal diseases: mapping experience in Russia.

    Science.gov (United States)

    Malkhazova, Svetlana M; Mironova, Varvara A; Kotova, Tatiana V; Shartova, Natalia V; Orlov, Dmitry S

    2014-06-14

    Natural-focal diseases constitute a serious hazard for human health. Agents and vectors of such diseases belong to natural landscapes. The aim of this study is to identify the diversity and geography of natural-focal diseases in Russia and to develop cartographic approaches for their mapping, including mathematical-cartographical modeling. Russian medico-geographical mapping of natural-focal diseases is highly developed regionally and locally but extremely limited at the national level. To solve this problem, a scientific team of the Faculty of Geography at Lomonosov Moscow State University has developed and implemented a project of a medico-geographical Atlas of Russia "Natural-Focal Diseases". The mapping is based on medical statistics data. The Atlas contains a series of maps on disease incidence, long-term dynamics of disease morbidity, etc. In addition, other materials available to the authors were used: mapping of the natural environment, field data, archival materials, analyzed satellite images, etc. The maps are processed using ArcGIS (ESRI) software application. Different methods of rendering of mapped phenomena are used (geographical ranges, diagrams, choropleth maps etc.). A series of analytical, integrated, and synthetic maps shows disease incidence in the population at both the national and regional levels for the last 15 years. Maps of the mean annual morbidity of certain infections and maps of morbidity dynamics and nosological profiles allow for a detailed analysis of the situation for each of 83 administrative units of the Russian Federation. The degree of epidemic hazard in Russia by natural-focal diseases is reflected in a synthetic medico-geographical map that shows the degree of epidemic risks due to such diseases in Russia and allows one to estimate the risk of disease manifestation in a given region. This is the first attempt at aggregation and public presentation of diverse and multifaceted information about natural-focal diseases in Russia

  1. Present-day stress magnitude at depth from leak-off tests in Italy

    Science.gov (United States)

    Mariucci, M. T.; Montone, P.; Pierdominici, S.

    2012-04-01

    We present new results from the analysis of leak-off tests, performed in deep oil wells in Italy, to characterize the present-day stress magnitude and regime in the crust. In the last years we have collected a large number of data (more than 500) from different stress indicators, mainly borehole breakouts, earthquake focal mechanisms and fault data, which provided information on the present-day stress orientations. In some areas the tectonic regime has been inferred either from fault plane solutions of M≥4 earthquakes or from stress inversions of smaller earthquakes. Where seismicity lacks, the regime is not well constrained and little or no information on the magnitude of the crustal stresses is available. In order to improve our knowledge in stress regime and its magnitude in Italy, in this work we use the leak-off test technique. Each test is performed at the bottom of an open hole by sealing off a section and then slowly pressurizing with a fluid until hydraulic tensile fractures develop. The minimum horizontal stress is inferred by leak-off pressure record, the vertical stress is computed by rock density data and the maximum horizontal stress is estimated applying a specific formula from the literature. Thanks to ENI S.p.A. (Italian oil company), that kindly provided new well data, we have been able to perform a critical review of our preliminary calculations and to enhance our previous results concerning stress magnitudes. Totally, we have analyzed 192 leak-off tests at depth between 200 and 5400m (average 1800m). In particular, wells are located along the Italian peninsula and in Sicily: most of them are in the Po Plain and along the Apenninic foredeep; few are in southern Apenninic belt and a few tens are in Sicily. After an accurate selection of the most robust results, we better characterize the Italian stress regime at depth.

  2. Focal lesions in the central nervous system

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Budinger, T.F.; Tobias, C.A.; Born, J.L.

    1980-01-01

    This report reviews the animal and human studies currently in progress at LBL with heavy-ion beams to induce focal lesions in the central nervous system, and discusses the potential future prospects of fundamental and applied brain research with heavy-ion beams. Methods are being developed for producing discrete focal lesions in the central nervous system using the Bragg ionization peak to investigate nerve pathways and neuroendocrine responses, and for treating pathological disorders of the brain

  3. Focal plane detector for QDD spectrography in Institute of Nuclear Study and detector for SMART 2nd focal plane in RIKEN

    Energy Technology Data Exchange (ETDEWEB)

    Fuchi, Yoshihide [Tokyo Univ., Tanashi (Japan). Inst. for Nuclear Study

    1996-09-01

    The focal plane detector for QDD spectrography in Institute of Nuclear Study was composed of drift space and a proportional counter tube, and the latter is composed of position detector and two delta E detector for recognizing the particles. In this detector, a uniform parallel electric field can be obtained by placing a guard plate at the same height as that of a drift plate outer place of the detector. On the other hand, the detector for SMART 2nd focal plate in RIKEN is composed of drift space and a single wire proportional counter, and has two cathode read out single wire drift counters set so as to hold the focal plane. (G.K.)

  4. A targeted resequencing gene panel for focal epilepsy.

    Science.gov (United States)

    Hildebrand, Michael S; Myers, Candace T; Carvill, Gemma L; Regan, Brigid M; Damiano, John A; Mullen, Saul A; Newton, Mark R; Nair, Umesh; Gazina, Elena V; Milligan, Carol J; Reid, Christopher A; Petrou, Steven; Scheffer, Ingrid E; Berkovic, Samuel F; Mefford, Heather C

    2016-04-26

    We report development of a targeted resequencing gene panel for focal epilepsy, the most prevalent phenotypic group of the epilepsies. The targeted resequencing gene panel was designed using molecular inversion probe (MIP) capture technology and sequenced using massively parallel Illumina sequencing. We demonstrated proof of principle that mutations can be detected in 4 previously genotyped focal epilepsy cases. We searched for both germline and somatic mutations in 251 patients with unsolved sporadic or familial focal epilepsy and identified 11 novel or very rare missense variants in 5 different genes: CHRNA4, GRIN2B, KCNT1, PCDH19, and SCN1A. Of these, 2 were predicted to be pathogenic or likely pathogenic, explaining ∼0.8% of the cohort, and 8 were of uncertain significance based on available data. We have developed and validated a targeted resequencing panel for focal epilepsies, the most important clinical class of epilepsies, accounting for about 60% of all cases. Our application of MIP technology is an innovative approach that will be advantageous in the clinical setting because it is highly sensitive, efficient, and cost-effective for screening large patient cohorts. Our findings indicate that mutations in known genes likely explain only a small proportion of focal epilepsy cases. This is not surprising given the established clinical and genetic heterogeneity of these disorders and underscores the importance of further gene discovery studies in this complex syndrome. © 2016 American Academy of Neurology.

  5. SU-G-206-08: How Should Focal Spot Be Chosen for Optimized CT Imaging with Dose Modulation?

    Energy Technology Data Exchange (ETDEWEB)

    Bache, S; Liu, X; Rong, J [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To choose the preferred focal spot for achieving optimized CT image quality with balanced tube heating considerations. Methods: An anthropomorphic pelvic phantom was scanned using a GE Discovery CT750 HD at 120 and 140kVp, 0.8s rotation time, and pitch of 0.984. “Smart mA” was enabled to simulate a routine abdomen–pelvis CT scan. Permissible mA values at 120 and 140 kVp were obtained from the Serial Load Rating table (for mimicking a busy CT clinical operation) in the scanner Technical Reference Manual. At each kVp station and two Noise Index levels, the mA Upper Limit was set above/below the permissible mA values. Scanned mA values and focal spot (FS) used were obtained from the DICOM header of each image, and the FS-mA relationship was analyzed. For visual confirmation beyond recorded FS information, a CatPhan with a fat-ring attached for mimicking patient size/shape was scanned at 120kVp. A group of radiologists/physicists compared a pair of CatPhan images qualitatively. Lastly, a number of patient cases were evaluated to confirm the FS-mA relationship. Results: When preset Upper Limit values were above the permissible mA values, the Large FS (labeled 1.2) was used in scans, even if the maximum scanned mA values were much lower than the permissible values at both 120 and 140 kVp. Otherwise the Small FS (labeled 0.7) was used. Visual evaluation of the high contrast module of CatPhan and additional analysis of patient cases further confirmed that the preset Upper Limit determines which focal spot is to be used, not the actual maximum mA value to be scanned. Conclusion: Specific FS can be selected by setting up appropriate mA Upper Limit in a protocol. CT protocols could be optimized by selecting appropriate FS for improving patient image quality, especially benefiting the small size and pediatric patients.

  6. SU-G-206-08: How Should Focal Spot Be Chosen for Optimized CT Imaging with Dose Modulation?

    International Nuclear Information System (INIS)

    Bache, S; Liu, X; Rong, J

    2016-01-01

    Purpose: To choose the preferred focal spot for achieving optimized CT image quality with balanced tube heating considerations. Methods: An anthropomorphic pelvic phantom was scanned using a GE Discovery CT750 HD at 120 and 140kVp, 0.8s rotation time, and pitch of 0.984. “Smart mA” was enabled to simulate a routine abdomen–pelvis CT scan. Permissible mA values at 120 and 140 kVp were obtained from the Serial Load Rating table (for mimicking a busy CT clinical operation) in the scanner Technical Reference Manual. At each kVp station and two Noise Index levels, the mA Upper Limit was set above/below the permissible mA values. Scanned mA values and focal spot (FS) used were obtained from the DICOM header of each image, and the FS-mA relationship was analyzed. For visual confirmation beyond recorded FS information, a CatPhan with a fat-ring attached for mimicking patient size/shape was scanned at 120kVp. A group of radiologists/physicists compared a pair of CatPhan images qualitatively. Lastly, a number of patient cases were evaluated to confirm the FS-mA relationship. Results: When preset Upper Limit values were above the permissible mA values, the Large FS (labeled 1.2) was used in scans, even if the maximum scanned mA values were much lower than the permissible values at both 120 and 140 kVp. Otherwise the Small FS (labeled 0.7) was used. Visual evaluation of the high contrast module of CatPhan and additional analysis of patient cases further confirmed that the preset Upper Limit determines which focal spot is to be used, not the actual maximum mA value to be scanned. Conclusion: Specific FS can be selected by setting up appropriate mA Upper Limit in a protocol. CT protocols could be optimized by selecting appropriate FS for improving patient image quality, especially benefiting the small size and pediatric patients.

  7. Critical Assessment of the Surface Tension determined by the Maximum Pressure Bubble Method

    OpenAIRE

    Benedetto, Franco Emmanuel; Zolotucho, Hector; Prado, Miguel Oscar

    2015-01-01

    The main factors that influence the value of surface tension of a liquid measured with the Maximum Pressure Bubble Method are critically evaluated. We present experimental results showing the effect of capillary diameter, capillary depth, bubble spheroidicity and liquid density at room temperature. We show that the decrease of bubble spheroidicity due to increase of capillary immersion depth is not sufficient to explain the deviations found in the measured surface tension values. Thus, we pro...

  8. Magnetic electroanatomical mapping for ablation of focal atrial tachycardias.

    Science.gov (United States)

    Marchlinski, F; Callans, D; Gottlieb, C; Rodriguez, E; Coyne, R; Kleinman, D

    1998-08-01

    Uniform success for ablation of focal atrial tachycardias has been difficult to achieve using standard catheter mapping and ablation techniques. In addition, our understanding of the complex relationship between atrial anatomy, electrophysiology, and surface ECG P wave morphology remains primitive. The magnetic electroanatomical mapping and display system (CARTO) offers an on-line display of electrical activation and/or signal amplitude related to the anatomical location of the recorded sites in the mapped chamber. A window of electrical interest is established based on signals timed from an electrical reference that usually represents a fixed electrogram recording from the coronary sinus or the atrial appendage. This window of electrical interest is established to include atrial activation prior to the onset of the P wave activity associated with the site of origin of a focal atrial tachycardia. Anatomical and electrical landmarks are defined with limited fluoroscopic imaging support and more detailed global chamber and more focal atrial mapping can be performed with minimal fluoroscopic guidance. A three-dimensional color map representing atrial activation or voltage amplitude at the magnetically defined anatomical sites is displayed with on-line data acquisition. This display can be manipulated to facilitate viewing from any angle. Altering the zoom control, triangle fill threshold, clipping plane, or color range can all enhance the display of a more focal area of interest. We documented the feasibility of using this single mapping catheter technique for localizing and ablating focal atrial tachycardias. In a consecutive series of 8 patients with 9 focal atrial tachycardias, the use of the single catheter CARTO mapping system was associated with ablation success in all but one patient who had a left atrial tachycardia localized to the medial aspect of the orifice of the left atrial appendage. Only low power energy delivery was used in this patient because of the

  9. Protein kinase C, focal adhesions and the regulation of cell migration

    DEFF Research Database (Denmark)

    Fogh, Betina S; Multhaupt, Hinke A B; Couchman, John Robert

    2014-01-01

    in their intracellular compartment. Among these are tyrosine kinases, which have received a great deal of attention, whereas the serine/threonine kinase protein kinase C has received much less. Here the status of protein kinase C in focal adhesions and cell migration is reviewed, together with discussion of its roles...... and adhesion turnover. Focal adhesions, or focal contacts, are widespread organelles at the cell-matrix interface. They arise as a result of receptor interactions with matrix ligands, together with clustering. Recent analysis shows that focal adhesions contain a very large number of protein components...

  10. Management of Localized Prostate Cancer by Focal Transurethral Resection of Prostate Cancer: An Application of Radical TUR-PCa to Focal Therapy.

    Science.gov (United States)

    Morita, Masaru; Matsuura, Takeshi

    2012-01-01

    Background. We analyzed radical TUR-PCa against localized prostate cancer. Patients and Methods. Seventy-nine out of 209 patients with prostate cancer in one lobe were studied. Patients' age ranged from 58 to 91 years and preoperative PSA, 0.70 to 17.30 ng/mL. In other 16 additional patients we performed focal TUR-PCa. Patients' age ranged from 51 to 87 years and preoperative PSA, 1.51 to 25.74 ng/mL. Results. PSA failure in radical TUR-PCa was 5.1% during the mean follow-up period of 58.9 months. The actuarial biochemical non-recurrence rate was 98.2% for pT2a and 90.5% for pT2b. Bladder neck contracture occurred in 28 patients (35.4%). In 209 patients, pathological study revealed prostate cancer of the peripheral zone near the neurovascular bundle bilaterally in 25%, unilaterally in 39% and no cancer bilaterally in 35%, suggesting the possibility of focal TUR-PCa. Postoperative PSA of 16 patients treated by focal TUR-PCa was stable between 0.007 and 0.406 ng/mL at 24.2 months' follow-up. No patients suffered from urinary incontinence. Bladder neck contracture developed in only 1 patient and all 5 patients underwent nerve-preserving TUR-PCa did not show erectile dysfunction. Conclusion. Focal TUR-PCa was considered to be a promising option among focal therapies against localized prostate cancer.

  11. Management of Localized Prostate Cancer by Focal Transurethral Resection of Prostate Cancer: An Application of Radical TUR-PCa to Focal Therapy

    Directory of Open Access Journals (Sweden)

    Masaru Morita

    2012-01-01

    Full Text Available Background. We analyzed radical TUR-PCa against localized prostate cancer. Patients and Methods. Seventy-nine out of 209 patients with prostate cancer in one lobe were studied. Patients’ age ranged from 58 to 91 years and preoperative PSA, 0.70 to 17.30 ng/mL. In other 16 additional patients we performed focal TUR-PCa. Patients’ age ranged from 51 to 87 years and preoperative PSA, 1.51 to 25.74 ng/mL. Results. PSA failure in radical TUR-PCa was 5.1% during the mean follow-up period of 58.9 months. The actuarial biochemical non-recurrence rate was 98.2% for pT2a and 90.5% for pT2b. Bladder neck contracture occurred in 28 patients (35.4%. In 209 patients, pathological study revealed prostate cancer of the peripheral zone near the neurovascular bundle bilaterally in 25%, unilaterally in 39% and no cancer bilaterally in 35%, suggesting the possibility of focal TUR-PCa. Postoperative PSA of 16 patients treated by focal TUR-PCa was stable between 0.007 and 0.406 ng/mL at 24.2 months’ follow-up. No patients suffered from urinary incontinence. Bladder neck contracture developed in only 1 patient and all 5 patients underwent nerve-preserving TUR-PCa did not show erectile dysfunction. Conclusion. Focal TUR-PCa was considered to be a promising option among focal therapies against localized prostate cancer.

  12. Focal cortical dysplasia – review

    International Nuclear Information System (INIS)

    Kabat, Joanna; Król, Przemysław

    2012-01-01

    Focal cortical dysplasia is a malformation of cortical development, which is the most common cause of medically refractory epilepsy in the pediatric population and the second/third most common etiology of medically intractable seizures in adults. Both genetic and acquired factors are involved in the pathogenesis of cortical dysplasia. Numerous classifications of the complex structural abnormalities of focal cortical dysplasia have been proposed – from Taylor et al. in 1971 to the last modification of Palmini classification made by Blumcke in 2011. In general, three types of cortical dysplasia are recognized. Type I focal cortical dysplasia with mild symptomatic expression and late onset, is more often seen in adults, with changes present in the temporal lobe. Clinical symptoms are more severe in type II of cortical dysplasia usually seen in children. In this type, more extensive changes occur outside the temporal lobe with predilection for the frontal lobes. New type III is one of the above dysplasias with associated another principal lesion as hippocampal sclerosis, tumor, vascular malformation or acquired pathology during early life. Brain MRI imaging shows abnormalities in the majority of type II dysplasias and in only some of type I cortical dysplasias. The most common findings on MRI imaging include: focal cortical thickening or thinning, areas of focal brain atrophy, blurring of the gray-white junction, increased signal on T2- and FLAIR-weighted images in the gray and subcortical white matter often tapering toward the ventricle. On the basis of the MRI findings, it is possible to differentiate between type I and type II cortical dysplasia. A complete resection of the epileptogenic zone is required for seizure-free life. MRI imaging is very helpful to identify those patients who are likely to benefit from surgical treatment in a group of patients with drug-resistant epilepsy. However, in type I cortical dysplasia, MR imaging is often normal, and also in both

  13. Effect of source depth correction on the estimation of earthquake size

    International Nuclear Information System (INIS)

    Romanelli, F.; Panza, G.

    1995-03-01

    The relationship between surface wave magnitude, M s , and seismic moment, M o , of earthquakes is essential for the estimation of seismic risk in any region. In the hypothesis of constant stress drop, theoretical models predict that Log M o and M s are related by a linear law. The slope most commonly found in the literature is around 1.5. Here we show that the application to the Ms values of the necessary correction for the focal depth, gives a general increment of the correlation coefficient, and that a slope around 1.0 is consistent with the global data, while for regionalized data it can vary from about 1.0 to 2.0. (author). 14 refs, 3 tabs

  14. Managing focal fields of vector beams with multiple polarization singularities.

    Science.gov (United States)

    Han, Lei; Liu, Sheng; Li, Peng; Zhang, Yi; Cheng, Huachao; Gan, Xuetao; Zhao, Jianlin

    2016-11-10

    We explore the tight focusing behavior of vector beams with multiple polarization singularities, and analyze the influences of the number, position, and topological charge of the singularities on the focal fields. It is found that the ellipticity of the local polarization states at the focal plane could be determined by the spatial distribution of the polarization singularities of the vector beam. When the spatial location and topological charge of singularities have even-fold rotation symmetry, the transverse fields at the focal plane are locally linearly polarized. Otherwise, the polarization state becomes a locally hybrid one. By appropriately arranging the distribution of the polarization singularities in the vector beam, the polarization distributions of the focal fields could be altered while the intensity maintains unchanged.

  15. Energy-depth relation of electrons in bulk targets by Monte-Carlo calculations

    International Nuclear Information System (INIS)

    Gaber, M.; Fitting, H.J.

    1984-01-01

    Monte-Carlo calculations are used to calculate the energy of penetrating electrons as a function of the depth in thick targets of Ti, Fe, Cu, As, In, and Au. It is shown that the mean energy ratio anti E(z)/E 0 decays exponentially with depth z and depends on the backscattering coefficient eta/sub B/ of the bulk material and the maximum range R(E 0 ) of the primary electrons with initial energy E 0 . Thereby a normalized plot anti E/E 0 as a function of the reduced depth z/R becomes possible. (author)

  16. Focal vitiligo: long-term follow-up of 52 cases

    NARCIS (Netherlands)

    Lommerts, J. E.; Schilder, Y.; de Rie, M. A.; Wolkerstorfer, A.; Bekkenk, M. W.

    2016-01-01

    Focal vitiligo is characterized by depigmented patches located in a small area without a typical segmental distribution. Focal vitiligo is classified as an undetermined type of vitiligo, and a more definitive diagnosis can be made when the lesions have not evolved into non-segmental or segmental

  17. A simple formula for depth dose calculation for Co-60 teletherapy beam dosimetry

    International Nuclear Information System (INIS)

    Tripathi, U.B.; Kelkar, N.Y.

    1979-01-01

    Knowledge of dose at all points of interest in the plane of tumour is essential for treatment planning. A very simple formula for scatter dose calculation along the central axis of a Co-60 beam has been derived. This formula uses primary dose at depth d, scatter air ratio at the depth of maximum ionisation and the effective depth of the volume, irradiating the medium. The method for calculation of percentage depth dose at any point in the principal plane has been explained in detail. The simple form of the formulation will help in improving the treatment plans for treatments of lesions using Co-60 teletherapy machines. (orig.) [de

  18. Option-4 algorithm for Florida pocket depth probe: reduction in the variance of site-specific probeable crevice depth measurements.

    Science.gov (United States)

    Breen, H J; Rogers, P; Johnson, N W; Slaney, R

    1999-08-01

    Clinical periodontal measurement is plagued by many sources of error which result in aberrant values (outliers). This study sets out to compare probeable crevice depth measurements (PCD) selected by the option-4 algorithm against those recorded with a conventional double-pass method and to quantify any reduction in site-specific PCD variances. A single clinician recorded full-mouth PCD at 1 visit in 32 subjects (mean age 45.5 years) with moderately advanced chronic adult periodontitis. PCD was recorded over 2 passes at 6 sites per tooth with the Florida Pocket Depth Probes, a 3rd generation probe. The option-4 algorithm compared the 1st pass site-specific PCD value (PCD1) to the 2nd pass site-specific PCD value (PCD2) and, if the difference between these values was >1.00 mm, allowed the recording of a maximum of 2 further measurements (3rd and 4th pass measurements PCD3 and PCD4): 4 site-specific measure-meets were considered to be the maximum subject and tissue tolerance. The algorithm selected the 1st 2 measurements whose difference was difference Y) (Y=[(A-B)/A]X 100) and a 75% reduction in the median site-specific variance of PCD1/PCD2.

  19. NeuroSeek dual-color image processing infrared focal plane array

    Science.gov (United States)

    McCarley, Paul L.; Massie, Mark A.; Baxter, Christopher R.; Huynh, Buu L.

    1998-09-01

    Several technologies have been developed in recent years to advance the state of the art of IR sensor systems including dual color affordable focal planes, on-focal plane array biologically inspired image and signal processing techniques and spectral sensing techniques. Pacific Advanced Technology (PAT) and the Air Force Research Lab Munitions Directorate have developed a system which incorporates the best of these capabilities into a single device. The 'NeuroSeek' device integrates these technologies into an IR focal plane array (FPA) which combines multicolor Midwave IR/Longwave IR radiometric response with on-focal plane 'smart' neuromorphic analog image processing. The readout and processing integrated circuit very large scale integration chip which was developed under this effort will be hybridized to a dual color detector array to produce the NeuroSeek FPA, which will have the capability to fuse multiple pixel-based sensor inputs directly on the focal plane. Great advantages are afforded by application of massively parallel processing algorithms to image data in the analog domain; the high speed and low power consumption of this device mimic operations performed in the human retina.

  20. Context cue focality influences strategic prospective memory monitoring.

    Science.gov (United States)

    Hunter Ball, B; Bugg, Julie M

    2018-02-12

    Monitoring the environment for the occurrence of prospective memory (PM) targets is a resource-demanding process that produces cost (e.g., slower responding) to ongoing activities. However, research suggests that individuals are able to monitor strategically by using contextual cues to reduce monitoring in contexts in which PM targets are not expected to occur. In the current study, we investigated the processes supporting context identification (i.e., determining whether or not the context is appropriate for monitoring) by testing the context cue focality hypothesis. This hypothesis predicts that the ability to monitor strategically depends on whether the ongoing task orients attention to the contextual cues that are available to guide monitoring. In Experiment 1, participants performed an ongoing lexical decision task and were told that PM targets (TOR syllable) would only occur in word trials (focal context cue condition) or in items starting with consonants (nonfocal context cue condition). In Experiment 2, participants performed an ongoing first letter judgment (consonant/vowel) task and were told that PM targets would only occur in items starting with consonants (focal context cue condition) or in word trials (nonfocal context cue condition). Consistent with the context cue focality hypothesis, strategic monitoring was only observed during focal context cue conditions in which the type of ongoing task processing automatically oriented attention to the relevant features of the contextual cue. These findings suggest that strategic monitoring is dependent on limited-capacity processing resources and may be relatively limited when the attentional demands of context identification are sufficiently high.

  1. Distribution of phytoplankton groups within the deep chlorophyll maximum

    KAUST Repository

    Latasa, Mikel

    2016-11-01

    The fine vertical distribution of phytoplankton groups within the deep chlorophyll maximum (DCM) was studied in the NE Atlantic during summer stratification. A simple but unconventional sampling strategy allowed examining the vertical structure with ca. 2 m resolution. The distribution of Prochlorococcus, Synechococcus, chlorophytes, pelagophytes, small prymnesiophytes, coccolithophores, diatoms, and dinoflagellates was investigated with a combination of pigment-markers, flow cytometry and optical and FISH microscopy. All groups presented minimum abundances at the surface and a maximum in the DCM layer. The cell distribution was not vertically symmetrical around the DCM peak and cells tended to accumulate in the upper part of the DCM layer. The more symmetrical distribution of chlorophyll than cells around the DCM peak was due to the increase of pigment per cell with depth. We found a vertical alignment of phytoplankton groups within the DCM layer indicating preferences for different ecological niches in a layer with strong gradients of light and nutrients. Prochlorococcus occupied the shallowest and diatoms the deepest layers. Dinoflagellates, Synechococcus and small prymnesiophytes preferred shallow DCM layers, and coccolithophores, chlorophytes and pelagophytes showed a preference for deep layers. Cell size within groups changed with depth in a pattern related to their mean size: the cell volume of the smallest group increased the most with depth while the cell volume of the largest group decreased the most. The vertical alignment of phytoplankton groups confirms that the DCM is not a homogeneous entity and indicates groups’ preferences for different ecological niches within this layer.

  2. Contributions of depth filter components to protein adsorption in bioprocessing.

    Science.gov (United States)

    Khanal, Ohnmar; Singh, Nripen; Traylor, Steven J; Xu, Xuankuo; Ghose, Sanchayita; Li, Zheng J; Lenhoff, Abraham M

    2018-04-16

    Depth filtration is widely used in downstream bioprocessing to remove particulate contaminants via depth straining and is therefore applied to harvest clarification and other processing steps. However, depth filtration also removes proteins via adsorption, which can contribute variously to impurity clearance and to reduction in product yield. The adsorption may occur on the different components of the depth filter, that is, filter aid, binder, and cellulose filter. We measured adsorption of several model proteins and therapeutic proteins onto filter aids, cellulose, and commercial depth filters at pH 5-8 and ionic strengths filter component in the adsorption of proteins with different net charges, using confocal microscopy. Our findings show that a complete depth filter's maximum adsorptive capacity for proteins can be estimated by its protein monolayer coverage values, which are of order mg/m 2 , depending on the protein size. Furthermore, the extent of adsorption of different proteins appears to depend on the nature of the resin binder and its extent of coating over the depth filter surface, particularly in masking the cation-exchanger-like capacity of the siliceous filter aids. In addition to guiding improved depth filter selection, the findings can be leveraged in inspiring a more intentional selection of components and design of depth filter construction for particular impurity removal targets. © 2018 Wiley Periodicals, Inc.

  3. Radiologic manifestations of focal cerebral hyperemia in acute stroke

    DEFF Research Database (Denmark)

    Olsen, Tom Skyhøj; Skriver, E B; Herning, M

    1991-01-01

    In 16 acute stroke patients with focal cerebral hyperemia angiography and regional cerebral blood flow (rCBF) were studied 1 to 4 days post stroke. CT was performed twice with and without contrast enhancement 3 +/- 1 days and 16 +/- 4 days post stroke. Angiographic evidence of focal cerebral hype...

  4. Focal airtrapping at expiratory high-resolution CT: comparison with pulmonary function tests

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Hast, J.; Heussel, C.P.; Mildenberger, P.; Thelen, M.; Schlegel, J.

    2000-01-01

    This study was undertaken to determine prevalence, extent, and severity of focal airtrapping at expiratory high-resolution CT, and to compare focal airtrapping with age, gender, pulmonary function tests, and blood gas analysis. Two-hundred seventeen patients with and without pulmonary disease underwent paired inspiratory/expiratory high-resolution CT. Six scan pairs with corresponding scan levels were visually assessed for focal - not diffuse - airtrapping using a four-point scale. Pulmonary function tests and blood gas analysis were available for correlation in all patients (mean interval 5 days). Focal airtrapping with lower lung predominance was observed in 80 % of patients. Twenty-six of 26 patients with restrictive lung function impairment exhibited focal airtrapping (mean score 2.4), whereas only 72 of 98 (74 %) patients with obstruction did (mean score 1.5; p < 0.05). Fifty-eight of 70 (83 %) patients with normal lung function (mean score 1.8) and 19 of 23 (83 %) patients with mixed impairment (mean score 1.8) had focal airtrapping. Focal airtrapping showed negative correlations with static lung volumes (-0.27 to -0.37; p < 0.001) in all patients and moderate positive correlations with dynamic parameters (0.3-0.4; p < 0.001) in patients with obstruction. No significant correlations were found with age, gender, and blood gas analysis. Visual assessment of focal - not diffuse - airtrapping at expiratory high-resolution CT does not correlate with physiological evidence of obstruction as derived from pulmonary function tests since the perception of focal airtrapping requires an adequate expiratory increase in lung density. (orig.)

  5. DEPDC5 takes a second hit in familial focal epilepsy.

    Science.gov (United States)

    Anderson, Matthew P

    2018-04-30

    Loss-of-function mutations in a single allele of the gene encoding DEP domain-containing 5 protein (DEPDC5) are commonly linked to familial focal epilepsy with variable foci; however, a subset of patients presents with focal cortical dysplasia that is proposed to result from a second-hit somatic mutation. In this issue of the JCI, Ribierre and colleagues provide several lines of evidence to support second-hit DEPDC5 mutations in this disorder. Moreover, the authors use in vivo, in utero electroporation combined with CRISPR-Cas9 technology to generate a murine model of the disease that recapitulates human manifestations, including cortical dysplasia-like changes, focal seizures, and sudden unexpected death. This study provides important insights into familial focal epilepsy and provides a preclinical model for evaluating potential therapies.

  6. Rasmussen's encephalitis presenting as focal cortical dysplasia

    Science.gov (United States)

    O'Rourke, D.J.; Bergin, A.; Rotenberg, A.; Peters, J.; Gorman, M.; Poduri, A.; Cryan, J.; Lidov, H.; Madsen, J.; Harini, C.

    2014-01-01

    Rasmussen's encephalitis is a rare syndrome characterized by intractable seizures, often associated with epilepsia partialis continua and symptoms of progressive hemispheric dysfunction. Seizures are usually the hallmark of presentation, but antiepileptic drug treatment fails in most patients and is ineffective against epilepsia partialis continua, which often requires surgical intervention. Co-occurrence of focal cortical dysplasia has only rarely been described and may have implications regarding pathophysiology and management. We describe a rare case of dual pathology of Rasmussen's encephalitis presenting as a focal cortical dysplasia (FCD) and discuss the literature on this topic. PMID:25667877

  7. Focal therapy in prostate cancer

    NARCIS (Netherlands)

    van den Bos, W.

    2016-01-01

    Interesting developments took place in the treatment of prostate cancer including focal therapy for less aggressive organ-confined prostate cancer. Fortunately, curative treatment is often still an option for patients suffering from the lower staged tumors. In carefully selected patients, the

  8. Gallbladder adenoma with focal adenocarcinoma.

    Science.gov (United States)

    Ciurea, S; Matei, E; Petrisor, P; Luca, L; Boros, Mirela; Herlea, V; Popescu, I

    2008-01-01

    The majority of polypoid lesions of the gallbladder are cholesterolosis pseudopolyps. True neoplastic GB polyps are represented mainly by adenomas. The case of a 52-year old male patient with an adenomatous polyp of the GB with focal adenocarcinoma is presented.

  9. Heterogeneity of Focal Adhesions and Focal Contacts in Motile Fibroblasts.

    Science.gov (United States)

    Gladkikh, Aleena; Kovaleva, Anastasia; Tvorogova, Anna; Vorobjev, Ivan A

    2018-01-01

    Cell-extracellular matrix (ECM) adhesion is an important property of virtually all cells in multicellular organisms. Cell-ECM adhesion studies, therefore, are very significant both for biology and medicine. Over the last three decades, biomedical studies resulted in a tremendous advance in our understanding of the molecular basis and functions of cell-ECM adhesion. Based on morphological and molecular criteria, several different types of model cell-ECM adhesion structures including focal adhesions, focal complexes, fibrillar adhesions, podosomes, and three-dimensional matrix adhesions have been described. All the subcellular structures that mediate cell-ECM adhesion are quite heterogeneous, often varying in size, shape, distribution, dynamics, and, to a certain extent, molecular constituents. The morphological "plasticity" of cell-ECM adhesion perhaps reflects the needs of cells to sense, adapt, and respond to a variety of extracellular environments. In addition, cell type (e.g., differentiation status, oncogenic transformation, etc.) often exerts marked influence on the structure of cell-ECM adhesions. Although molecular, genetic, biochemical, and structural studies provide important maps or "snapshots" of cell-ECM adhesions, the area of research that is equally valuable is to study the heterogeneity of FA subpopulations within cells. Recently time-lapse observations on the FA dynamics become feasible, and behavior of individual FA gives additional information on cell-ECM interactions. Here we describe a robust method of labeling of FA using plasmids with fluorescent markers for paxillin and vinculin and quantifying the morphological and dynamical parameters of FA.

  10. Systematic study of the focal shift effect in planar plasmonic slit lenses

    International Nuclear Information System (INIS)

    Hu Bin; Wang Qijie; Zhang Ying

    2012-01-01

    In this paper, we systematically studied the focal shift effect in planar plasmonic slit lenses. Through theoretical derivations and numerical simulations, we found that there is a focal length shift between the traditional design model and the finite-difference time-domain simulations. The shift is not only dependent on the Fresnel number (FN) of the lens, like traditional dielectric lenses, determined by the lens width and the designed focal length, but also on the surface plasmon polariton (SPPs) interaction on the lens surfaces, dependent on the slit numbers. We also found that the FN-induced focal shift is predominant when FN 1. An approximated theoretical model is presented to estimate the focal shift of plasmonic slit lens with FN < 1. (paper)

  11. Protein kinase C involvement in focal adhesion formation

    DEFF Research Database (Denmark)

    Woods, A; Couchman, J R

    1992-01-01

    Matrix molecules such as fibronectin can promote cell attachment, spreading and focal adhesion formation. Although some interactions of fibronectin with cell surface receptors have now been identified, the consequent activation of intracellular messenger systems by cell/matrix interactions have...... still to be elucidated. We show here that the kinase inhibitors H7 and HA1004 reduce focal adhesion and stress fiber formation in response to fibronectin in a dose-dependent manner, and that activators of protein kinase C can promote their formation under conditions where they do not normally form....... Fibroblasts spread within 1h on substrata composed of fibronectin and formed focal adhesions by 3h, as monitored by interference reflection microscopy (IRM) and by labeling for talin, vinculin and integrin beta 1 subunits. In addition, stress fibers were visible. When cells were allowed to spread for 1h...

  12. A Comparison between Deep and Shallow Stress Fields in Korea Using Earthquake Focal Mechanism Inversions and Hydraulic Fracturing Stress Measurements

    Science.gov (United States)

    Lee, Rayeon; Chang, Chandong; Hong, Tae-kyung; Lee, Junhyung; Bae, Seong-Ho; Park, Eui-Seob; Park, Chan

    2016-04-01

    We are characterizing stress fields in Korea using two types of stress data: earthquake focal mechanism inversions (FMF) and hydraulic fracturing stress measurements (HF). The earthquake focal mechanism inversion data represent stress conditions at 2-20 km depths, whereas the hydraulic fracturing stress measurements, mostly conducted for geotechnical purposes, have been carried out at depths shallower than 1 km. We classified individual stress data based on the World Stress Map quality ranking scheme. A total of 20 FMF data were classified into A-B quality, possibly representing tectonic stress fields. A total of 83 HF data out of compiled 226 data were classified into B-C quality, which we use for shallow stress field characterization. The tectonic stress, revealed from the FMF data, is characterized by a remarkable consistency in its maximum stress (σ1) directions in and around Korea (N79±2° E), indicating a quite uniform deep stress field throughout. On the other hand, the shallow stress field, represented by HF data, exhibits local variations in σ1 directions, possibly due to effects of topography and geologic structures such as faults. Nonetheless, there is a general similarity in σ1 directions between deep and shallow stress fields. To investigate the shallow stress field statistically, we follow 'the mean orientation and wavelength analysis' suggested by Reiter et al. (2014). After the stress pattern analysis, the resulting stress points distribute sporadically over the country, not covering the entire region evenly. In the western part of Korea, the shallow σ1directions are generally uniform with their search radius reaching 100 km, where the average stress direction agrees well with those of the deep tectonic stress. We note two noticeable differences between shallow and deep stresses in the eastern part of Korea. First, the shallow σ1 orientations are markedly non-uniform in the southeastern part of Korea with their search radius less than 25 km

  13. A 1.3 giga pixels focal plane for GAIA

    Science.gov (United States)

    Laborie, Anouk; Pouny, Pierre; Vetel, Cyril; Collados, Emmanuel; Rougier, Gilles; Davancens, Robert; Zayer, Igor; Perryman, Michael; Pace, Oscar

    2004-06-01

    The astrometric mission GAIA is a cornerstone mission of the European Space Agency, due for launch in the 2010 time frame. Requiring extremely demanding performance GAIA calls for the development of an unprecedented large focal plane featuring innovative technologies. For securing the very challenging GAIA development, a significant number of technology activities have been initiated by ESA through a competitive selection process. In this context, an industrial consortium led by EADS-Astrium (France) with e2v technologies (UK) as major subcontractor was selected for the GAIA CCD and Focal Plane Technology Demonstrators programme, which is by far the most significant and the most critical GAIA pre-development for all aspects: science performance, development schedule and cost. This programme has started since August 2002 and will end early 2005 prior to commencement of the GAIA Phase B. While the GAIA payload will host three instruments and related focal planes, the major mission objectives are assigned to the Astrometric (ASTRO) Focal Plane, which is the subject of this presentation.

  14. Focal adhesions, stress fibers and mechanical tension

    Energy Technology Data Exchange (ETDEWEB)

    Burridge, Keith, E-mail: Keith_Burridge@med.unc.edu [Department of Cell Biology and Physiology, and Lineberger Comprehensive Cancer Center, 12-016 Lineberger, CB#7295, University of North Carolina, Chapel Hill, NC (United States); Guilluy, Christophe, E-mail: christophe.guilluy@univ-nantes.fr [Inserm UMR-S1087, CNRS UMR-C6291, L' institut du Thorax, and Université de Nantes, Nantes (France)

    2016-04-10

    Stress fibers and focal adhesions are complex protein arrays that produce, transmit and sense mechanical tension. Evidence accumulated over many years led to the conclusion that mechanical tension generated within stress fibers contributes to the assembly of both stress fibers themselves and their associated focal adhesions. However, several lines of evidence have recently been presented against this model. Here we discuss the evidence for and against the role of mechanical tension in driving the assembly of these structures. We also consider how their assembly is influenced by the rigidity of the substratum to which cells are adhering. Finally, we discuss the recently identified connections between stress fibers and the nucleus, and the roles that these may play, both in cell migration and regulating nuclear function. - Highlights: • The different types of stress fiber and focal adhesion are described. • We discuss the controversy about tension and assembly of these structures. • We describe the different models used to investigate assembly of these structures. • The influence of substratum rigidity is discussed. • Stress fiber connections to the nucleus are reviewed.

  15. Deuterium depth profiles in metals using imaging field desorption

    International Nuclear Information System (INIS)

    Panitz, J.A.

    1976-01-01

    Depth profiles of 80 eV deuterium ions implanted in-situ into (110) tungsten have been measured by Imaging, Field-Desorption Mass Spectrometry. The relative abundance of deuterium was measured from the surface to a depth of 300A with less than 3A depth resolution by controlled field-evaporation of the specimen, and time-of-flight mass spectroscopy. The position of the depth distribution maximum (57 +- 3A from the surface) is shown to be in close agreement with that predicted theoretically for low energy deuterium implants using an amorphous-solid model. Structure in the distribution is attributed to surface morphology and channeling phenomena in the near surface region. Implanted impurity species from the ion source and tungsten surface have also been observed. For C + , C 2+ and 0 + , penetration is limited to less than 30A, with abundance decreasing exponentially from the surface. These results are interpreted in the context of the CTR first-wall impurity problem, and are used to suggest a novel method for in-situ characterization of low energy plasma species in operating CTR devices

  16. MRI of a family with focal abnormalities of gyration

    International Nuclear Information System (INIS)

    Muntaner, L.; Perez-Ferron, J.J.; Herrera, M.; Rosell, J.; Taboada, D.; Climent, S.

    1997-01-01

    Focal abnormalities of gyration (FAG) are developmental disorders that may occur in isolated patients or, as in the case being reported, as part of a familial disorder. Analysis of individuals in a family spanning three generations was carried out using MRI. Abnormalities, present in all members of generations II and III, included focal cortical dysplasia (three patients), focal cortical infolding (two patients) and schizencephaly (one patient); associated minor anomalies, such as white matter abnormalities, were seen in the remaining three members of generations II and III. MRI recognition of FAG in the family being reported proved useful in defining their phenotypical expression and providing proper counselling for individual family members. (orig.). With 6 figs

  17. Concordance of MRI and EEG Focal Slowing in Nonsyndromic Epilepsy

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2013-04-01

    Full Text Available Investigators at the Kangwon National University, Korea, and The Epilepsy Center, Lurie Children’s Hospital of Chicago, USA studied the correlation and significance of EEG focal slowing and focal MRI abnormalities in 253 children with nonsyndromic epilepsy.

  18. Focal low-dose rate brachytherapy for the treatment of prostate cancer

    Directory of Open Access Journals (Sweden)

    Tong WY

    2013-09-01

    Full Text Available William Y Tong, Gilad Cohen, Yoshiya Yamada Memorial Sloan-Kettering Cancer Center, Department of Radiation Oncology, New York, NY, USA Abstract: Whole-gland low-dose rate (LDR brachytherapy has been a well-established modality of treating low-risk prostate cancer. Treatment in a focal manner has the advantages of reduced toxicity to surrounding organs. Focal treatment using LDR brachytherapy has been relatively unexplored, but it may offer advantages over other modalities that have established experiences with a focal approach. This is particularly true as prostate cancer is being detected at an earlier and more localized stage with the advent of better detection methods and newer imaging modalities. Keywords: prostate cancer, focal, low dose rate, brachytherapy

  19. Dosimetry Modeling for Focal Low-Dose-Rate Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Al-Qaisieh, Bashar [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Mason, Josh, E-mail: joshua.mason@nhs.net [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Bownes, Peter; Henry, Ann [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Dickinson, Louise [Division of Surgery and Interventional Science, University College London, London (United Kingdom); Department of Radiology, Northwick Park Hospital, London North West NHS Trust, London (United Kingdom); Ahmed, Hashim U. [Division of Surgery and Interventional Science, University College London, London (United Kingdom); University College London Hospital, London (United Kingdom); Emberton, Mark [University College London Hospital, London (United Kingdom); Langley, Stephen [St Luke' s Cancer Centre, Guildford (United Kingdom)

    2015-07-15

    Purpose: Focal brachytherapy targeted to an individual lesion(s) within the prostate may reduce side effects experienced with whole-gland brachytherapy. The outcomes of a consensus meeting on focal prostate brachytherapy were used to investigate optimal dosimetry of focal low-dose-rate (LDR) prostate brachytherapy targeted using multiparametric magnetic resonance imaging (mp-MRI) and transperineal template prostate mapping (TPM) biopsy, including the effects of random and systematic seed displacements and interseed attenuation (ISA). Methods and Materials: Nine patients were selected according to clinical characteristics and concordance of TPM and mp-MRI. Retrospectively, 3 treatment plans were analyzed for each case: whole-gland (WG), hemi-gland (hemi), and ultra-focal (UF) plans, with 145-Gy prescription dose and identical dose constraints for each plan. Plan robustness to seed displacement and ISA were assessed using Monte Carlo simulations. Results: WG plans used a mean 28 needles and 81 seeds, hemi plans used 17 needles and 56 seeds, and UF plans used 12 needles and 25 seeds. Mean D90 (minimum dose received by 90% of the target) and V100 (percentage of the target that receives 100% dose) values were 181.3 Gy and 99.8% for the prostate in WG plans, 195.7 Gy and 97.8% for the hemi-prostate in hemi plans, and 218.3 Gy and 99.8% for the focal target in UF plans. Mean urethra D10 was 205.9 Gy, 191.4 Gy, and 92.4 Gy in WG, hemi, and UF plans, respectively. Mean rectum D2 cm{sup 3} was 107.5 Gy, 77.0 Gy, and 42.7 Gy in WG, hemi, and UF plans, respectively. Focal plans were more sensitive to seed displacement errors: random shifts with a standard deviation of 4 mm reduced mean target D90 by 14.0%, 20.5%, and 32.0% for WG, hemi, and UF plans, respectively. ISA has a similar impact on dose-volume histogram parameters for all plan types. Conclusions: Treatment planning for focal LDR brachytherapy is feasible. Dose constraints are easily met with a notable

  20. Metallic plates lens focalizing a high power microwave beam

    International Nuclear Information System (INIS)

    Rebuffi, L.

    1987-08-01

    A metallic grating composed of thin parallel plates opportunely spaced, permits to correct the phase of an incident high power microwave beam. In this work we show how it is possible to obtain a beam focalisation (lens), a beam deflection (prisma), or a variation in the polarization (polarizer) using parallel metallic plates. The main design parameters are here presented, in order to obtain the wanted phase modification keeping low the diffraction, the reflected power, the ohmic losses and avoiding breakdowns. Following the given criteria, a metallic plate lens has been realized to focalize the 200 KW, 100 msec 60 GHz beam used in the ECRH experiment on the TFR tokamak. The experimental beam concentration followed satisfactory the design requirements. In fact, the maximum intensity increased about twice the value without lens. In correspondence of this distance a reduction of the beam size of about 50% have been measured for the -3 dB radius. The lens supported high power tests without breakdowns or increase of the reflected power

  1. Detection is unaffected by the deployment of focal attention

    Directory of Open Access Journals (Sweden)

    Jeff eMoher

    2013-05-01

    Full Text Available There has been much debate regarding how much information humans can extract from their environment without the use of limited attentional resources. In a recent study, Theeuwes, Van der Burg, and Belopolsky (2008 argued that even detection of simple feature targets is not possible without selection by focal attention. Supporting this claim, they found response time benefits in a simple feature (color detection task when a target letter’s identity was repeated on consecutive trials, suggesting that the letter was selected by focal attention and identified prior to detection. This intertrial repetition benefit remained even when observers were required to simultaneously identify a central digit. However, we found that intertrial repetition benefits disappeared when a simple color target was presented among a heterogeneously (rather than homogeneously colored set of distractors, thus reducing its bottom-up salience. Still, detection performance remained high. Thus, detection performance was unaffected by whether a letter was focally attended and identified prior to detection or not. Intertrial identity repetition benefits also disappeared when observers were required to perform a simultaneous, attention-demanding central task (Experiment 2, or when unfamiliar Chinese characters were used (Experiment 3. Together, these results suggest that while shifts of focal attention can be affected by target salience, by the availability of excess cognitive resources, and by target familiarity, detection performance itself is unaffected by these manipulations and is thus unaffected by the deployment of focal attention.

  2. Effect of source depth correction on the estimation of earthquake size

    Energy Technology Data Exchange (ETDEWEB)

    Romanelli, F [Universita degli Studi di Trieste, Trieste (Italy). Istituto di Geodesia e Geofisica; Panza, G

    1995-03-01

    The relationship between surface wave magnitude, M{sub s}, and seismic moment, M{sub o}, of earthquakes is essential for the estimation of seismic risk in any region. In the hypothesis of constant stress drop, theoretical models predict that Log M{sub o} and M{sub s} are related by a linear law. The slope most commonly found in the literature is around 1.5. Here we show that the application to the Ms values of the necessary correction for the focal depth, gives a general increment of the correlation coefficient, and that a slope around 1.0 is consistent with the global data, while for regionalized data it can vary from about 1.0 to 2.0. (author). 14 refs, 3 tabs.

  3. Depth enhancement of S3D content and the psychological effects

    Science.gov (United States)

    Hirahara, Masahiro; Shiraishi, Saki; Kawai, Takashi

    2012-03-01

    Stereoscopic 3D (S3D) imaging technologies are widely used recently to create content for movies, TV programs, games, etc. Although S3D content differs from 2D content by the use of binocular parallax to induce depth sensation, the relationship between depth control and the user experience remains unclear. In this study, the user experience was subjectively and objectively evaluated in order to determine the effectiveness of depth control, such as an expansion or reduction or a forward or backward shift in the range of maximum parallactic angles in the cross and uncross directions (depth bracket). Four types of S3D content were used in the subjective and objective evaluations. The depth brackets of comparison stimuli were modified in order to enhance the depth sensation corresponding to the content. Interpretation Based Quality (IBQ) methodology was used for the subjective evaluation and the heart rate was measured to evaluate the physiological effect. The results of the evaluations suggest the following two points. (1) Expansion/reduction of the depth bracket affects preference and enhances positive emotions to the S3D content. (2) Expansion/reduction of the depth bracket produces above-mentioned effects more notable than shifting the cross/uncross directions.

  4. Rasmussen's encephalitis presenting as focal cortical dysplasia

    Directory of Open Access Journals (Sweden)

    D.J. O'Rourke

    2014-01-01

    Full Text Available Rasmussen's encephalitis is a rare syndrome characterized by intractable seizures, often associated with epilepsia partialis continua and symptoms of progressive hemispheric dysfunction. Seizures are usually the hallmark of presentation, but antiepileptic drug treatment fails in most patients and is ineffective against epilepsia partialis continua, which often requires surgical intervention. Co-occurrence of focal cortical dysplasia has only rarely been described and may have implications regarding pathophysiology and management. We describe a rare case of dual pathology of Rasmussen's encephalitis presenting as a focal cortical dysplasia (FCD and discuss the literature on this topic.

  5. Depth Estimates for Slingram Electromagnetic Anomalies from Dipping Sheet-like Bodies by the Normalized Full Gradient Method

    Science.gov (United States)

    Dondurur, Derman

    2005-11-01

    The Normalized Full Gradient (NFG) method was proposed in the mid 1960s and was generally used for the downward continuation of the potential field data. The method eliminates the side oscillations which appeared on the continuation curves when passing through anomalous body depth. In this study, the NFG method was applied to Slingram electromagnetic anomalies to obtain the depth of the anomalous body. Some experiments were performed on the theoretical Slingram model anomalies in a free space environment using a perfectly conductive thin tabular conductor with an infinite depth extent. The theoretical Slingram responses were obtained for different depths, dip angles and coil separations, and it was observed from NFG fields of the theoretical anomalies that the NFG sections yield the depth information of top of the conductor at low harmonic numbers. The NFG sections consisted of two main local maxima located at both sides of the central negative Slingram anomalies. It is concluded that these two maxima also locate the maximum anomaly gradient points, which indicates the depth of the anomaly target directly. For both theoretical and field data, the depth of the maximum value on the NFG sections corresponds to the depth of the upper edge of the anomalous conductor. The NFG method was applied to the in-phase component and correct depth estimates were obtained even for the horizontal tabular conductor. Depth values could be estimated with a relatively small error percentage when the conductive model was near-vertical and/or the conductor depth was larger.

  6. Chest pain in focal musculoskeletal disorders

    DEFF Research Database (Denmark)

    Stochkendahl, Mette Jensen; Christensen, Henrik Wulff

    2010-01-01

    overlapping conditions and syndromes of focal disorders, including Tietze syndrome, costochondritis, chest wall syndrome, muscle tenderness, slipping rib, cervical angina, and segmental dysfunction of the cervical and thoracic spine, have been reported to cause pain. For most of these syndromes, evidence......The musculoskeletal system is a recognized source of chest pain. However, despite the apparently benign origin, patients with musculoskeletal chest pain remain under-diagnosed, untreated, and potentially continuously disabled in terms of anxiety, depression, and activities of daily living. Several...... arises mainly from case stories and empiric knowledge. For segmental dysfunction, clinical features of musculoskeletal chest pain have been characterized in a few clinical trials. This article summarizes the most commonly encountered syndromes of focal musculoskeletal disorders in clinical practice....

  7. Mechanical design and analysis of focal plate for gravity deformation

    Science.gov (United States)

    Wang, Jianping; Chu, Jiaru; Hu, Hongzhuan; Li, Kexuan; Zhou, Zengxiang

    2014-07-01

    The surface accuracy of astronomical telescope focal plate is a key indicator to precision stellar observation. To conduct accurate deformation measurement for focal plate in different status, a 6-DOF hexapod platform was used for attitude adjustment. For the small adjustment range of a classic 6-DOF hexapod platform, an improved structural arrangement method was proposed in the paper to achieve ultimate adjustment of the focal plate in horizontal and vertical direction. To validate the feasibility of this method, an angle change model which used ball hinge was set up for the movement and base plate. Simulation results in MATLAB suggested that the ball hinge angle change of movement and base plate is within the range of the limiting angle in the process of the platform plate adjusting to ultimate attitude. The proposed method has some guiding significance for accurate surface measurement of focal plate.

  8. The deconvolution of sputter-etching surface concentration measurements to determine impurity depth profiles

    International Nuclear Information System (INIS)

    Carter, G.; Katardjiev, I.V.; Nobes, M.J.

    1989-01-01

    The quasi-linear partial differential continuity equations that describe the evolution of the depth profiles and surface concentrations of marker atoms in kinematically equivalent systems undergoing sputtering, ion collection and atomic mixing are solved using the method of characteristics. It is shown how atomic mixing probabilities can be deduced from measurements of ion collection depth profiles with increasing ion fluence, and how this information can be used to predict surface concentration evolution. Even with this information, however, it is shown that it is not possible to deconvolute directly the surface concentration measurements to provide initial depth profiles, except when only ion collection and sputtering from the surface layer alone occur. It is demonstrated further that optimal recovery of initial concentration depth profiles could be ensured if the concentration-measuring analytical probe preferentially sampled depths near and at the maximum depth of bombardment-induced perturbations. (author)

  9. A Water Temperature Simulation Model for Rice Paddies With Variable Water Depths

    Science.gov (United States)

    Maruyama, Atsushi; Nemoto, Manabu; Hamasaki, Takahiro; Ishida, Sachinobu; Kuwagata, Tsuneo

    2017-12-01

    A water temperature simulation model was developed to estimate the effects of water management on the thermal environment in rice paddies. The model was based on two energy balance equations: for the ground and for the vegetation, and considered the water layer and changes in the aerodynamic properties of its surface with water depth. The model was examined with field experiments for water depths of 0 mm (drained conditions) and 100 mm (flooded condition) at two locations. Daily mean water temperatures in the flooded condition were mostly higher than in the drained condition in both locations, and the maximum difference reached 2.6°C. This difference was mainly caused by the difference in surface roughness of the ground. Heat exchange by free convection played an important role in determining water temperature. From the model simulation, the temperature difference between drained and flooded conditions was more apparent under low air temperature and small leaf area index conditions; the maximum difference reached 3°C. Most of this difference occurred when the range of water depth was lower than 50 mm. The season-long variation in modeled water temperature showed good agreement with an observation data set from rice paddies with various rice-growing seasons, for a diverse range of water depths (root mean square error of 0.8-1.0°C). The proposed model can estimate water temperature for a given water depth, irrigation, and drainage conditions, which will improve our understanding of the effect of water management on plant growth and greenhouse gas emissions through the thermal environment of rice paddies.

  10. Microbial diversity from chlorophyll maximum, oxygen minimum and bottom zones in the southwestern Atlantic Ocean

    Science.gov (United States)

    Medina-Silva, Renata; de Oliveira, Rafael R.; Pivel, Maria A. G.; Borges, Luiz G. A.; Simão, Taiz L. L.; Pereira, Leandro M.; Trindade, Fernanda J.; Augustin, Adolpho H.; Valdez, Fernanda P.; Eizirik, Eduardo; Utz, Laura R. P.; Groposo, Claudia; Miller, Dennis J.; Viana, Adriano R.; Ketzer, João M. M.; Giongo, Adriana

    2018-02-01

    Conspicuous physicochemical vertical stratification in the deep sea is one of the main forces driving microbial diversity in the oceans. Oxygen and sunlight availability are key factors promoting microbial diversity throughout the water column. Ocean currents also play a major role in the physicochemical stratification, carrying oxygen down to deeper zones as well as moving deeper water masses up towards shallower depths. Water samples within a 50-km radius in a pockmark location of the southwestern Atlantic Ocean were collected and the prokaryotic communities from different water depths - chlorophyll maximum, oxygen minimum and deep-sea bottom (down to 1355 m) - were described. At phylum level, Proteobacteria were the most frequent in all water depths, Cyanobacteria were statistically more frequent in chlorophyll maximum zone, while Thaumarchaeota were significantly more abundant in both oxygen minimum and bottom waters. The most frequent microorganism in the chlorophyll maximum and oxygen minimum zones was a Pelagibacteraceae operational taxonomic unit (OTU). At the bottom, the most abundant genus was the archaeon Nitrosopumilus. Beta diversity analysis of the 16S rRNA gene sequencing data uncovered in this study shows high spatial heterogeneity among water zones communities. Our data brings important contribution for the characterisation of oceanic microbial diversity, as it consists of the first description of prokaryotic communities occurring in different oceanic water zones in the southwestern Atlantic Ocean.

  11. Charging as a Focal Practice

    DEFF Research Database (Denmark)

    Bødker, Mads

    This position paper reflects on Borgmann’s notion of ‘focal things’ and its applicability in the discourse about interaction with technologies in nature. Using the example of a combined cooking burner and thermoelectric 5W smartphone charger (a BioLite cook stove), this position paper gives...

  12. CT findings of focal organizing pneumonia: correlation with pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yang Soo; Kim, Young Goo; Park, Un Sup [College of Medicine, Chungang University, Seoul (Korea, Republic of)

    1994-11-15

    To evaluate the CT findings of focal organizing pneumonia and to correlate them with pathologic findings to help differentiating from lung cancer. We evaluated radiologic and pathologic findings of five patients with solitary pulmonary nodule which were confirmed as focal organizing pneumonia pathologically. On CT scan, focal organizing pneumonia had irregular margin contacting the pleura in all five cases. The shape of the nodules were spherical to wedge or elliptical and the size from 3.5cm to 5.5cm(average 4.2 cm) in largest diameter. On postcontrast CT scan, all nodules showed enhancement and four cases showed central low density components. Two nodules contained air within the nodule. In four cases, pleural changes such as effusion and/or focal thickening were noted. No lymphadenopathy was found in all cases. Pathologically, the enhancing portion on CT showed findings of organizing pneumonia such as granulation tissue with fibroblast proliferation in alveolar space and interstitial thickening. The central low density areas on CT were due to ischemic necrosis, abscess and exudate, transudate and infiltration of foamy histiocyte. The possibility of focal organizing pneumonia should be considered when peripherally located solitary pulmonary nodule had enhancing component with no combined lymphadenopathy on CT scan.

  13. CT findings of focal organizing pneumonia: correlation with pathologic findings

    International Nuclear Information System (INIS)

    Kim, Yang Soo; Kim, Young Goo; Park, Un Sup

    1994-01-01

    To evaluate the CT findings of focal organizing pneumonia and to correlate them with pathologic findings to help differentiating from lung cancer. We evaluated radiologic and pathologic findings of five patients with solitary pulmonary nodule which were confirmed as focal organizing pneumonia pathologically. On CT scan, focal organizing pneumonia had irregular margin contacting the pleura in all five cases. The shape of the nodules were spherical to wedge or elliptical and the size from 3.5cm to 5.5cm(average 4.2 cm) in largest diameter. On postcontrast CT scan, all nodules showed enhancement and four cases showed central low density components. Two nodules contained air within the nodule. In four cases, pleural changes such as effusion and/or focal thickening were noted. No lymphadenopathy was found in all cases. Pathologically, the enhancing portion on CT showed findings of organizing pneumonia such as granulation tissue with fibroblast proliferation in alveolar space and interstitial thickening. The central low density areas on CT were due to ischemic necrosis, abscess and exudate, transudate and infiltration of foamy histiocyte. The possibility of focal organizing pneumonia should be considered when peripherally located solitary pulmonary nodule had enhancing component with no combined lymphadenopathy on CT scan

  14. EEG dynamical correlates of focal and diffuse causes of coma.

    Science.gov (United States)

    Kafashan, MohammadMehdi; Ryu, Shoko; Hargis, Mitchell J; Laurido-Soto, Osvaldo; Roberts, Debra E; Thontakudi, Akshay; Eisenman, Lawrence; Kummer, Terrance T; Ching, ShiNung

    2017-11-15

    Rapidly determining the causes of a depressed level of consciousness (DLOC) including coma is a common clinical challenge. Quantitative analysis of the electroencephalogram (EEG) has the potential to improve DLOC assessment by providing readily deployable, temporally detailed characterization of brain activity in such patients. While used commonly for seizure detection, EEG-based assessment of DLOC etiology is less well-established. As a first step towards etiological diagnosis, we sought to distinguish focal and diffuse causes of DLOC through assessment of temporal dynamics within EEG signals. We retrospectively analyzed EEG recordings from 40 patients with DLOC with consensus focal or diffuse culprit pathology. For each recording, we performed a suite of time-series analyses, then used a statistical framework to identify which analyses (features) could be used to distinguish between focal and diffuse cases. Using cross-validation approaches, we identified several spectral and non-spectral EEG features that were significantly different between DLOC patients with focal vs. diffuse etiologies, enabling EEG-based classification with an accuracy of 76%. Our findings suggest that DLOC due to focal vs. diffuse injuries differ along several electrophysiological parameters. These results may form the basis of future classification strategies for DLOC and coma that are more etiologically-specific and therefore therapeutically-relevant.

  15. Tratamento focal e perifocal contra Aëdes aegypti

    Directory of Open Access Journals (Sweden)

    Milton Moura Lima

    1987-06-01

    Full Text Available Em quatro bairros da cidade do Rio de Janeiro, foram feitos ensaios de tratamento focal com abate granulado a 1 ppm e perifocal com pó molhável de Sumition a 2,5%. Esses tratamentos foram feitos tanto isoladamente quanto em conjunto e, também, associados à aplicação de inseticida a ultrabaixo volume. Os índices prediais, levantados um mês depois de terminado o trabalho, mostraram que o tratamento focal dispensa qualquer medida auxiliar. O tratamento perifocal mostrou-se inócuo e incapaz de impedir o aparecimento de larvas de Aëdes aegypti e de outros insetos, em pneus pintados, na face externa, com Sumition e com Malation.In four districts of the city of Rio dc Janeiro focal treatment essays with granulated Abate at 1 ppm and perifocal treatment essays with wettable powder of Sumithion at 2,5% were performed. These were made either alone or in combination as well as associated to insecticides applied at ultra low volume. The premise indices obtained one month after the treatments indicates that the focal treatment alone is effective, no other addicional methods being necessary. The perifocal treatment is not effective and did not prevent the development of Aedes aegypti larvae and other insects in tires which had their external surface painted with Sumithion and Malathion.

  16. [Focal myositis: An unknown disease].

    Science.gov (United States)

    Gallay, L; Streichenberger, N; Benveniste, O; Allenbach, Y

    2017-10-01

    Focal myositis are inflammatory muscle diseases of unknown origin. At the opposite from the other idiopathic inflammatory myopathies, they are restricted to a single muscle or to a muscle group. They are not associated with extramuscular manifestations, and they have a good prognosis without any treatment. They are characterized by a localized swelling affecting mostly lower limbs. The pseudo-tumor can be painful, but is not associated with a muscle weakness. Creatine kinase level is normal. Muscle MRI shows an inflammation restricted to a muscle or a muscle group. Muscle biopsy and pathological analysis remain necessary for the diagnosis, showing inflammatory infiltrates composed by macrophages and lymphocytes without any specific distribution within the muscle. Focal overexpression of HLA-1 by the muscle fibers is frequently observed. The muscle biopsy permits to rule out differential diagnosis such a malignancy (sarcoma). Spontaneous remission occurs within weeks or months after the first symptoms, relapse is unusual. Copyright © 2017. Published by Elsevier SAS.

  17. Theory of the mechanical response of focal adhesions to shear flow

    International Nuclear Information System (INIS)

    Biton, Y Y; Safran, S A

    2010-01-01

    The response of cells to shear flow is primarily determined by the asymmetry of the external forces and moments that are sensed by each member of a focal adhesion pair connected by a contractile stress fiber. In the theory presented here, we suggest a physical model in which each member of such a pair of focal adhesions is treated as an elastic body subject to both a myosin-activated contractile force and the shear stress induced by the external flow. The elastic response of a focal adhesion complex is much faster than the active cellular processes that determine the size of the associated focal adhesions and the direction of the complex relative to the imposed flow. Therefore, the complex attains its mechanical equilibrium configuration which may change because of the cellular activity. Our theory is based on the experimental observation that focal adhesions modulate their cross-sectional area in order to attain an optimal shear. Using this assumption, our elastic model shows that such a complex can passively change its orientation to align parallel to the direction of the flow.

  18. Neuro-fuzzy GMDH based particle swarm optimization for prediction of scour depth at downstream of grade control structures

    Directory of Open Access Journals (Sweden)

    Mohammad Najafzadeh

    2015-03-01

    Full Text Available In the present study, neuro-fuzzy based-group method of data handling (NF-GMDH as an adaptive learning network was utilized to predict the maximum scour depth at the downstream of grade-control structures. The NF-GMDH network was developed using particle swarm optimization (PSO. Effective parameters on the scour depth include sediment size, geometry of weir, and flow characteristics in the upstream and downstream of structure. Training and testing of performances were carried out using non-dimensional variables. Datasets were divided into three series of dataset (DS. The testing results of performances were compared with the gene-expression programming (GEP, evolutionary polynomial regression (EPR model, and conventional techniques. The NF-GMDH-PSO network produced lower error of the scour depth prediction than those obtained using the other models. Also, the effective input parameter on the maximum scour depth was determined through a sensitivity analysis.

  19. Focal decompositions for linear differential equations of the second order

    Directory of Open Access Journals (Sweden)

    L. Birbrair

    2003-01-01

    two-points problems to itself such that the image of the focal decomposition associated to the first equation is a focal decomposition associated to the second one. In this paper, we present a complete classification for linear second-order equations with respect to this equivalence relation.

  20. Focal spot motion of linear accelerators and its effect on portal image analysis

    International Nuclear Information System (INIS)

    Sonke, Jan-Jakob; Brand, Bob; Herk, Marcel van

    2003-01-01

    The focal spot of a linear accelerator is often considered to have a fully stable position. In practice, however, the beam control loop of a linear accelerator needs to stabilize after the beam is turned on. As a result, some motion of the focal spot might occur during the start-up phase of irradiation. When acquiring portal images, this motion will affect the projected position of anatomy and field edges, especially when low exposures are used. In this paper, the motion of the focal spot and the effect of this motion on portal image analysis are quantified. A slightly tilted narrow slit phantom was placed at the isocenter of several linear accelerators and images were acquired (3.5 frames per second) by means of an amorphous silicon flat panel imager positioned ∼0.7 m below the isocenter. The motion of the focal spot was determined by converting the tilted slit images to subpixel accurate line spread functions. The error in portal image analysis due to focal spot motion was estimated by a subtraction of the relative displacement of the projected slit from the relative displacement of the field edges. It was found that the motion of the focal spot depends on the control system and design of the accelerator. The shift of the focal spot at the start of irradiation ranges between 0.05-0.7 mm in the gun-target (GT) direction. In the left-right (AB) direction the shift is generally smaller. The resulting error in portal image analysis due to focal spot motion ranges between 0.05-1.1 mm for a dose corresponding to two monitor units (MUs). For 20 MUs, the effect of the focal spot motion reduces to 0.01-0.3 mm. The error in portal image analysis due to focal spot motion can be reduced by reducing the applied dose rate

  1. Contact mechanics of reverse total shoulder arthroplasty during abduction: the effect of neck-shaft angle, humeral cup depth, and glenosphere diameter.

    Science.gov (United States)

    Langohr, G Daniel G; Willing, Ryan; Medley, John B; Athwal, George S; Johnson, James A

    2016-04-01

    Implant design parameters can be changed during reverse shoulder arthroplasty (RSA) to improve range of motion and stability; however, little is known regarding their impact on articular contact mechanics. The purpose of this finite element study was to investigate RSA contact mechanics during abduction for different neck-shaft angles, glenosphere sizes, and polyethylene cup depths. Finite element RSA models with varying neck-shaft angles (155°, 145°, 135°), sizes (38 mm, 42 mm), and cup depths (deep, normal, shallow) were loaded with 400 N at physiological abduction angles. The contact area and maximum contact stress were computed. The contact patch and the location of maximum contact stress were typically located inferomedially in the polyethylene cup. On average for all abduction angles investigated, reducing the neck-shaft angle reduced the contact area by 29% for 155° to 145° and by 59% for 155° to 135° and increased maximum contact stress by 71% for 155° to 145° and by 286% for 155° to 135°. Increasing the glenosphere size increased the contact area by 12% but only decreased maximum contact stress by 2%. Decreasing the cup depth reduced the contact area by 40% and increased maximum contact stress by 81%, whereas increasing the depth produced the opposite effect (+52% and -36%, respectively). The location of the contact patch and maximum contact stress in this study matches the area of damage seen frequently on clinical retrievals. This finding suggests that damage to the inferior cup due to notching may be potentiated by contact stresses. Increasing the glenosphere diameter improved the joint contact area and did not affect maximum contact stress. However, although reducing the neck-shaft angle and cup depth can improve range of motion, our study shows that this also has some negative effects on RSA contact mechanics, particularly when combined. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc

  2. Focal myositis of lower extremity responsive to botulinum A toxin.

    Science.gov (United States)

    Mitrovic, Josko; Prka, Zeljko; Zic, Rado; Marusic, Srecko; Morovic-Vergles, Jadranka

    2014-01-01

    Focal myositis is a rare, mostly benign disease (pseudotumor) of skeletal muscle, histopathologically characterized by interstitial myositis and tumorous enlargement of a single muscle. The etiology of focal myositis remains unknown; however, localized myopathy has been postulated to be caused by denervation lesions. This case report describes a patient that presented with clinical, laboratory, electromyoneurography, and magnetic resonance imaging features of focal myositis complicated with intervertebral disk protrusion in the lumbosacral spine affected with radicular distress. In most cases, focal myositic lesions show spontaneous regression, relapses are rare, and long-term prognosis is good. There is a wide spectrum of therapeutic options, from no therapy at all through nonsteroidal antirheumatics and glucocorticoids to radiotherapy, surgical excision, and immunosuppressants. In the patient presented, treatment with glucocorticoids, methotrexate, and surgical excision failed to produce satisfactory results. Clinical improvement, pain relief, and reduction in lower leg volume were only achieved by local infiltration of botulinum A toxin.

  3. Deriving the effective focal plane for the CBM-RICH detector

    Energy Technology Data Exchange (ETDEWEB)

    Kres, Ievgenii [Wuppertal University (Germany); Collaboration: CBM-Collaboration

    2016-07-01

    The Compressed Baryonic Matter (CBM) experiment at the future FAIR complex will investigate the phase diagram of strongly interacting matter at high baryon density and moderate temperatures in A+A collisions from 2-11 AGeV (SIS100). A central component of the proposed detector setup is a ring imaging Cherenkov detector (RICH) using CO2 as radiator gas, and a focussing optic with a large spherical mirror. In the present design, the optimal focal plane is approximated using four individual, flat detection surfaces. However, the exact shape and position of the ideal focal plane is subject to further optimization due to effects from tilting the focussing mirror and from momentum dependant deflection of the electron tracks in the magnetic stray field. In this talk, we present a new approach to derive the effective 3-dimensional shape of the focal plane based on a set of Monte Carlo simulations, comparing the ring sharpness at each point of a preliminary focal plane as function of z-position.

  4. Preliminary results of very fast computation of Moment Magnitude and focal mechanism in the context of tsunami warning

    Science.gov (United States)

    Schindelé, François; Roch, Julien; Rivera, Luis

    2015-04-01

    Various methodologies were recently developed to compute the moment magnitude and the focal mechanism, thanks to the real time access to numerous broad-band seismic data. Several methods were implemented at the CENALT, in particular the W-Phase method developed by H. Kanamori and L. Rivera. For earthquakes of magnitudes in the range 6.5-9.0, this method provides accurate results in less than 40 minutes. The context of the tsunami warning in Mediterranean, a small basin impacted in less than one hour, and with small sources but some with high tsunami potential (Boumerdes 2003), a comprehensive tsunami warning system in that region should include very fast computation of the seismic parameters. The results of the values of Mw, the focal depth and the type of fault (reverse, normal, strike-slip) are the most relevant parameters expected for the tsunami warning. Preliminary results will be presented using data in the North-eastern and Mediterranean region for the recent period 2010-2014. This work is funded by project ASTARTE - - Assessment, Strategy And Risk Reduction for Tsunamis in Europe - FP7-ENV2013 6.4-3, Grant 603839

  5. Symmetric lens with extended depth of focus

    OpenAIRE

    Cho, Sung Nae

    2008-01-01

    The lens surface profile is derived based on the instantaneous focal length versus the lens radius data. The lens design based on instantaneous focal length versus the lens radius data has many useful applications in software assisted image focusing technology.

  6. Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector.

    Science.gov (United States)

    Russo, Paolo; Mettivier, Giovanni

    2011-04-01

    The goal of this study is to evaluate a new method based on a coded aperture mask combined with a digital x-ray imaging detector for measurements of the focal spot sizes of diagnostic x-ray tubes. Common techniques for focal spot size measurements employ a pinhole camera, a slit camera, or a star resolution pattern. The coded aperture mask is a radiation collimator consisting of a large number of apertures disposed on a predetermined grid in an array, through which the radiation source is imaged onto a digital x-ray detector. The method of the coded mask camera allows one to obtain a one-shot accurate and direct measurement of the two dimensions of the focal spot (like that for a pinhole camera) but at a low tube loading (like that for a slit camera). A large number of small apertures in the coded mask operate as a "multipinhole" with greater efficiency than a single pinhole, but keeping the resolution of a single pinhole. X-ray images result from the multiplexed output on the detector image plane of such a multiple aperture array, and the image of the source is digitally reconstructed with a deconvolution algorithm. Images of the focal spot of a laboratory x-ray tube (W anode: 35-80 kVp; focal spot size of 0.04 mm) were acquired at different geometrical magnifications with two different types of digital detector (a photon counting hybrid silicon pixel detector with 0.055 mm pitch and a flat panel CMOS digital detector with 0.05 mm pitch) using a high resolution coded mask (type no-two-holes-touching modified uniformly redundant array) with 480 0.07 mm apertures, designed for imaging at energies below 35 keV. Measurements with a slit camera were performed for comparison. A test with a pinhole camera and with the coded mask on a computed radiography mammography unit with 0.3 mm focal spot was also carried out. The full width at half maximum focal spot sizes were obtained from the line profiles of the decoded images, showing a focal spot of 0.120 mm x 0.105 mm at 35

  7. Super-resolution links vinculin localization to function in focal adhesions.

    Science.gov (United States)

    Giannone, Grégory

    2015-07-01

    Integrin-based focal adhesions integrate biochemical and biomechanical signals from the extracellular matrix and the actin cytoskeleton. The combination of three-dimensional super-resolution imaging and loss- or gain-of-function protein mutants now links the nanoscale dynamic localization of proteins to their activation and function within focal adhesions.

  8. Membership Functions for Fuzzy Focal Elements

    Directory of Open Access Journals (Sweden)

    Porębski Sebastian

    2016-09-01

    Full Text Available The paper presents a study on data-driven diagnostic rules, which are easy to interpret by human experts. To this end, the Dempster-Shafer theory extended for fuzzy focal elements is used. Premises of the rules (fuzzy focal elements are provided by membership functions which shapes are changing according to input symptoms. The main aim of the present study is to evaluate common membership function shapes and to introduce a rule elimination algorithm. Proposed methods are first illustrated with the popular Iris data set. Next experiments with five medical benchmark databases are performed. Results of the experiments show that various membership function shapes provide different inference efficiency but the extracted rule sets are close to each other. Thus indications for determining rules with possible heuristic interpretation can be formulated.

  9. Focal epilepsy in the Belgian shepherd

    DEFF Research Database (Denmark)

    Berendt, Mette; Gulløv, Christina Hedal; Fredholm, Merete

    2009-01-01

    and deceased) were ascertained through a telephone interview using a standardised questionnaire regarding seizure history and phenomenology. Living dogs were invited to a detailed clinical evaluation. Litters more than five years of age, or where epilepsy was present in all offspring before the age of five......, were included in the calculations of inheritance. results: Out of 199 family members, 66 dogs suffered from epilepsy. The prevalence of epilepsy in the family was 33%. Fifty-five dogs experienced focal seizures with or without secondary generalisation, while four dogs experienced primary generalised...... seizures. In seven dogs, seizures could not be classified. The mode of inheritance of epilepsy was simple Mendelian. CLINICAL SIGNIFICANCE: This study identified that the Belgian shepherd suffers from genetically transmitted focal epilepsy. The seizure phenomenology expressed by family members have...

  10. Extensive Focal Epithelial Hyperplasia: A Case Report.

    Science.gov (United States)

    Mansouri, Zahra; Bakhtiari, Sedigheh; Noormohamadi, Robab

    2015-01-01

    Focal epithelial hyperplasia (FEH) or Heck's disease is a rare viral infection of the oral mucosa caused by human papilloma virus especially subtypes 13 or 32. The frequency of this disease varies widely from one geographic region and ethnic groups to another. This paper reports an Iranian case of extensive focal epithelial hyperplasia. A 35-year-old man with FEH is described, in whom the lesions had persisted for more than 25 years. The lesion was diagnosed according to both clinical and histopathological features. Dental practitioner should be aware of these types of lesions and histopathological examination together and a careful clinical observation should be carried out for a definitive diagnosis.

  11. Focal splenic masses of the extramedullary hematopoiesis

    International Nuclear Information System (INIS)

    Incedayi, M.; Sivrioglu, A.

    2012-01-01

    Full text: Extramedullary hematopoiesis arises from pleuripotential stem cells distributed throughout the body. It is most common in patients with congenital hemolytic anemia, such as thalassemia, sickle cell anemia and hereditary spherocytosis as a response to ineffective red blood cell formation. Although microscopic foci of Extramedullary hematopoiesis are commonly seen in the spleen and liver parenchyma, focal mass-like lesion of extramedullary hematopoiesis in the liver and spleen are rare. We report a case of intrasplenic focal extramedullary hematopoiesis lesions and the imaging features of extramedullary hematopoiesis on computed tomography and magnetic resonance imaging. Extramedullary hematopoiesis should always be considered as a diagnosis in a patient with a known hematological disorder

  12. Correlation between Focal Nodular Low Signal Changes in Hoffa’s Fat Pad Adjacent to Anterior Femoral Cartilage and Focal Cartilage Defect Underlying This Region and Its Possible Implication

    Directory of Open Access Journals (Sweden)

    Chermaine Deepa Antony

    2016-01-01

    Full Text Available Purpose. This study investigates the association between focal nodular mass with low signal in Hoffa’s fat pad adjacent to anterior femoral cartilage of the knee (FNMHF and focal cartilage abnormality in this region. Method. The magnetic resonance fast imaging employing steady-state acquisition sequence (MR FIESTA sagittal and axial images of the B1 and C1 region (described later of 148 patients were independently evaluated by two reviewers and categorized into four categories: normal, FNMHF with underlying focal cartilage abnormality, FNMHF with normal cartilage, and cartilage abnormality with no FNMHF. Results. There was a significant association (p=0.00 between FNMHF and immediate adjacent focal cartilage abnormality with high interobserver agreement. The absence of focal nodular lesions next to the anterior femoral cartilage has a very high negative predictive value for chondral injury (97.8%. Synovial biopsy of focal nodular lesion done during arthroscopy revealed some fibrocollagenous tissue and no inflammatory cells. Conclusion. We postulate that the FNMHF adjacent to the cartilage defects is a form of normal healing response to the cartilage damage. One patient with FHMHF and underlying cartilage abnormality was rescanned six months later. In this patient, the FNMHF disappeared and normal cartilage was observed in the adjacent region which may support this theory.

  13. Focal myositis of the thigh: unusual MR pattern

    International Nuclear Information System (INIS)

    Llauger, Jaume; Palmer, Jaume; San Roman, Luis; Bague, Silvia; Matias-Guiu, Xavier; Doncel, Antonio

    2002-01-01

    Focal myositis is a commonly referenced, infrequently reported and poorly documented benign inflammatory pseudotumor which may be misdiagnosed clinically as a malignant tumor. We report the clinicopathologic features and magnetic resonance imaging findings in a case of focal myositis in the thigh of a 55-year-old woman. A different radiologic presentation of this disorder is described. The gross appearance of the lesion, previously undescribed, appears to be rather specific for such a pseudoneoplastic disorder, and correlates very well with the magnetic resonance imaging features. (orig.)

  14. Focal myositis of the thigh: unusual MR pattern

    Energy Technology Data Exchange (ETDEWEB)

    Llauger, Jaume; Palmer, Jaume; San Roman, Luis [Department of Radiology, Hospital de la Santa Creu i Sant Pau, Barcelona (Spain); Bague, Silvia; Matias-Guiu, Xavier [Department of Pathology, Hospital de la Santa Creu i Sant Pau, Barcelona (Spain); Doncel, Antonio [Department of Orthopedic Surgery, Hospital de la Santa Creu i Sant Pau, Barcelona (Spain)

    2002-05-01

    Focal myositis is a commonly referenced, infrequently reported and poorly documented benign inflammatory pseudotumor which may be misdiagnosed clinically as a malignant tumor. We report the clinicopathologic features and magnetic resonance imaging findings in a case of focal myositis in the thigh of a 55-year-old woman. A different radiologic presentation of this disorder is described. The gross appearance of the lesion, previously undescribed, appears to be rather specific for such a pseudoneoplastic disorder, and correlates very well with the magnetic resonance imaging features. (orig.)

  15. Expansion characteristics of coronary stents in focal stenoses

    Directory of Open Access Journals (Sweden)

    Schmidt Wolfram

    2017-09-01

    Full Text Available The presented experimental in vitro approach was designed to assess the expansion behavior of stent systems in a resistant focal stenosis model with respect to a potential dog-boning effect. Five different stent systems (nominal diameter 3.0 mm were investigated. The focal stenosis was simulated by a stainless steel tube (ID ≤ 1.20 mm. Stent expansion was performed using a proprietary test device consisting of a test chamber with 37 °C water, 2-axis laser scanner and a pressure controller.

  16. Determination of the paraxial focal length using Zernike polynomials over different apertures

    Science.gov (United States)

    Binkele, Tobias; Hilbig, David; Henning, Thomas; Fleischmann, Friedrich

    2017-02-01

    The paraxial focal length is still the most important parameter in the design of a lens. As presented at the SPIE Optics + Photonics 2016, the measured focal length is a function of the aperture. The paraxial focal length can be found when the aperture approaches zero. In this work, we investigate the dependency of the Zernike polynomials on the aperture size with respect to 3D space. By this, conventional wavefront measurement systems that apply Zernike polynomial fitting (e.g. Shack-Hartmann-Sensor) can be used to determine the paraxial focal length, too. Since the Zernike polynomials are orthogonal over a unit circle, the aperture used in the measurement has to be normalized. By shrinking the aperture and keeping up with the normalization, the Zernike coefficients change. The relation between these changes and the paraxial focal length are investigated. The dependency of the focal length on the aperture size is derived analytically and evaluated by simulation and measurement of a strong focusing lens. The measurements are performed using experimental ray tracing and a Shack-Hartmann-Sensor. Using experimental ray tracing for the measurements, the aperture can be chosen easily. Regarding the measurements with the Shack-Hartmann- Sensor, the aperture size is fixed. Thus, the Zernike polynomials have to be adapted to use different aperture sizes by the proposed method. By doing this, the paraxial focal length can be determined from the measurements in both cases.

  17. Improved image quality for asymmetric double-focal cone-beam SPECT

    International Nuclear Information System (INIS)

    Cao, Z.J.; Tsui, B.M.W.

    1993-01-01

    To optimize both spatial resolution and detection efficiency in brain SPECT imaging using a rectangular camera, an asymmetric double-focal cone-beam collimator is proposed with the focal points located near the base plane of the patient's head. To fit the entire head into the field-of-view of the collimator with dimensions of 50cmx40cm and at a radius-of-rotation of 15 cm, the focal lengths of the collimator are 55 and 70 cm, respectively, in the transverse and axial directions. With this geometry, the artifacts in the reconstructed image produced by the Feldkamp algorithm are more severe compared to those in a symmetric cone-beam geometry, due to the larger vertex angle between the top of the head and the base plane. To improve the reconstructed image quality, a fully three-dimensional (3D) reconstruction algorithm developed previously for single-focal cone-beam SPECT was extended to the asymmetric double-focal cone-beam geometry. The algorithm involves nonstationary 2D filtering and a reprojection technique for estimation of the missing data caused by a single-orbit cone-beam geometry. The results from simulation studies with the 3D Defrise slab phantom demonstrated that the fully 3D algorithm provided a much improved image quality in terms of reduced slice-to-slice cross talks and shape elongation compared to that produced by the conventional Feldkamp algorithm

  18. CT and ERCP findings of chronic focal pancreatitis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hee Soo; Lee, Jong Tae; Yoo, Hyung Sik; Kim, Eun Kyeong [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-10-01

    To evaluate the major radiologic features of chronic focal pancreatitis in various imaging studies, with special emphasis on CT and ERCP findings. From 1991 to 1995, twelve patients were pathologically proved to be suffering from focal chronic pancreatitis after pancreatico-duodenectomy;for retrospective evaluation, imaging studies were available for eight(seven men, one woman;mean age 58.9{+-}6.6, range 47 to 67). Clinical, surgical, and radiological findings, including CT(n=8), ultrasound(n=7), ERCP(n=8) and UGI(n=3) were analysed. Seven male patients had suffered from chronic alcoholism for between 20 and 50 years. Serum bilirubin levels were normal in eight patients and alkaline phosphatase levels were normal in seven patients. Serum CA 19-9 levels were normal in all five patients who had undergone preoperative evaluation. Seven patients(87.5%) showed focal enlargement without definable margin on CT, and five of the six lesions detectable on ultrasound(83.3%) were ill defined hypoechoic nodules. Dilated side branches within lesions were seen in five of eight patients(83.3%) on CT and ERCP. Double duct signs were observed in siven(87.5%) patients, and dilated intrahepatic ducts in six(75%), with diameters ranging from 5 to 8mm(average:5.42{+-}1.96mm). The average ratio of pancreatic duct caliber to gland width was 0.33{+-}0.19. None of the patients had calcification within the lesion and one case showed intraductal calcification. None showed perivascular fat obliteration around the superior mesenteric artery or celiac axis. The average biductal distance between abnormal common bile duct and the immediately adjacent pancreatic duct was 4.0{+-}1.15mm. One of three cases who under went a UGI examination showed severe luminal narrowing and mucosal thickening in the second protion of the duodenum, another showed double contour, and the other merely showed widening of the C-loop of the duodenum. Chronic focal pancreatitis mostly demonstrated ill defined focal

  19. CT and ERCP findings of chronic focal pancreatitis

    International Nuclear Information System (INIS)

    Kim, Hee Soo; Lee, Jong Tae; Yoo, Hyung Sik; Kim, Eun Kyeong

    1996-01-01

    To evaluate the major radiologic features of chronic focal pancreatitis in various imaging studies, with special emphasis on CT and ERCP findings. From 1991 to 1995, twelve patients were pathologically proved to be suffering from focal chronic pancreatitis after pancreatico-duodenectomy;for retrospective evaluation, imaging studies were available for eight(seven men, one woman;mean age 58.9±6.6, range 47 to 67). Clinical, surgical, and radiological findings, including CT(n=8), ultrasound(n=7), ERCP(n=8) and UGI(n=3) were analysed. Seven male patients had suffered from chronic alcoholism for between 20 and 50 years. Serum bilirubin levels were normal in eight patients and alkaline phosphatase levels were normal in seven patients. Serum CA 19-9 levels were normal in all five patients who had undergone preoperative evaluation. Seven patients(87.5%) showed focal enlargement without definable margin on CT, and five of the six lesions detectable on ultrasound(83.3%) were ill defined hypoechoic nodules. Dilated side branches within lesions were seen in five of eight patients(83.3%) on CT and ERCP. Double duct signs were observed in siven(87.5%) patients, and dilated intrahepatic ducts in six(75%), with diameters ranging from 5 to 8mm(average:5.42±1.96mm). The average ratio of pancreatic duct caliber to gland width was 0.33±0.19. None of the patients had calcification within the lesion and one case showed intraductal calcification. None showed perivascular fat obliteration around the superior mesenteric artery or celiac axis. The average biductal distance between abnormal common bile duct and the immediately adjacent pancreatic duct was 4.0±1.15mm. One of three cases who under went a UGI examination showed severe luminal narrowing and mucosal thickening in the second protion of the duodenum, another showed double contour, and the other merely showed widening of the C-loop of the duodenum. Chronic focal pancreatitis mostly demonstrated ill defined focal enlargement and

  20. [Primary focal dystonia: descriptive study of 205 patients].

    Science.gov (United States)

    Bartolomé, F M; Fanjul, S; Cantarero, S; Hernández, J; García Ruiz, P J

    2003-03-01

    To describe the clinical and epidemiologic aspects of different types of focal dystonia. A total of 205 patients with primary focal dystonia were studied retrospectively and the following variables were analyzed: gender, age of onset, age at examination, evolution time, history of trauma, association with other movement disorders, fluctuations of dystonic symptoms as well as a family history of dystonia, Parkinson's disease, tremor, and lefthandedness or stuttering. We compared these variables among the different clinical categories of focal dystonia. Those patients with cranial and laryngeal dystonia were significantly older at the onset of symptoms compared with patients with writer's cramp. Males were more prevalent than females in all categories of focal dystonia except for cranial dystonia. Prior history of trauma and association with tremor were more frequent in patients with cervical dystonia than in those with others dystonic categories. Most patients with cranial, cervical and laryngeal dystonia had fluctuations in the intensity of dystonic symptoms, unlike the patients with writer's cramp. There is a caudo-cranial gradient in age of onset and the age of onset increases as the cranial presentation becomes greater. Females are more prevalent in cranial dystonia and there is a preponderance of males in the dystonias with a lower location. The dystonias with cranial distribution frequently present fluctuations of symptoms during the day. Association with other movement disorders, such as tremor, and prior history of trauma, is common in patients with cervical dystonia.

  1. Quantum-Well Infrared Photodetector (QWIP) Focal Plane Assembly

    Science.gov (United States)

    Jhabvala, Murzy; Jhabvala, Christine A.; Ewin, Audrey J.; Hess, Larry A.; Hartmann, Thomas M.; La, Anh T.

    2012-01-01

    A paper describes the Thermal Infrared Sensor (TIRS), a QWIP-based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a far-infrared imager operating in the pushbroom mode with two IR channels: 10.8 and 12 microns. The focal plane will contain three 640x512 QWIP arrays mounted on a silicon substrate. The silicon substrate is a custom-fabricated carrier board with a single layer of aluminum interconnects. The general fabrication process starts with a 4-in. (approx.10-cm) diameter silicon wafer. The wafer is oxidized, a single substrate contact is etched, and aluminum is deposited, patterned, and alloyed. This technology development is aimed at incorporating three large-format infrared detecting arrays based on GaAs QWIP technology onto a common focal plane with precision alignment of all three arrays. This focal plane must survive the rigors of flight qualification and operate at a temperature of 43 K (-230 C) for five years while orbiting the Earth. The challenges presented include ensuring thermal compatibility among all the components, designing and building a compact, somewhat modular system and ensuring alignment to very tight levels. The multi-array focal plane integrated onto a single silicon substrate is a new application of both QWIP array development and silicon wafer scale integration. The Invar-based assembly has been tested to ensure thermal reliability.

  2. Genetics Home Reference: focal dermal hypoplasia

    Science.gov (United States)

    ... in people with focal dermal hypoplasia is an omphalocele , which is an opening in the wall of ... Dermal Hypoplasia MedlinePlus Encyclopedia: Ectodermal dysplasia MedlinePlus Encyclopedia: Omphalocele General Information from MedlinePlus (5 links) Diagnostic Tests ...

  3. Performance of an Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

    Science.gov (United States)

    Newman, Kevin; Belikov, Ruslan; Pluzhnik, Eugene; Balasubramanian, Kunjithapatham; Wilson, Dan

    2014-01-01

    Coronagraph technology combined with wavefront control is close to achieving the contrast and inner working angle requirements in the lab necessary to observe the faint signal of an Earth-like exoplanet in monochromatic light. An important remaining technological challenge is to achieve high contrast in broadband light. Coronagraph bandwidth is largely limited by chromaticity of the focal plane mask, which is responsible for blocking the stellar PSF. The size of a stellar PSF scales linearly with wavelength; ideally, the size of the focal plane mask would also scale with wavelength. A conventional hard-edge focal plane mask has a fixed size, normally sized for the longest wavelength in the observational band to avoid starlight leakage. The conventional mask is oversized for shorter wavelengths and blocks useful discovery space. Recently we presented a solution to the size chromaticity challenge with a focal plane mask designed to scale its effective size with wavelength. In this paper, we analyze performance of the achromatic size-scaling focal plane mask within a Phase Induced Amplitude Apodization (PIAA) coronagraph. We present results from wavefront control around the achromatic focal plane mask, and demonstrate the size-scaling effect of the mask with wavelength. The edge of the dark zone, and therefore the inner working angle of the coronagraph, scale with wavelength. The achromatic mask enables operation in a wider band of wavelengths compared with a conventional hard-edge occulter.

  4. Butterfly Wings Are Three-Dimensional: Pupal Cuticle Focal Spots and Their Associated Structures in Junonia Butterflies.

    Science.gov (United States)

    Taira, Wataru; Otaki, Joji M

    2016-01-01

    Butterfly wing color patterns often contain eyespots, which are developmentally determined at the late larval and early pupal stages by organizing activities of focal cells that can later form eyespot foci. In the pupal stage, the focal position of a future eyespot is often marked by a focal spot, one of the pupal cuticle spots, on the pupal surface. Here, we examined the possible relationships of the pupal focal spots with the underneath pupal wing tissues and with the adult wing eyespots using Junonia butterflies. Large pupal focal spots were found in two species with large adult eyespots, J. orithya and J. almana, whereas only small pupal focal spots were found in a species with small adult eyespots, J. hedonia. The size of five pupal focal spots on a single wing was correlated with the size of the corresponding adult eyespots in J. orithya. A pupal focal spot was a three-dimensional bulge of cuticle surface, and the underside of the major pupal focal spot exhibited a hollowed cuticle in a pupal case. Cross sections of a pupal wing revealed that the cuticle layer shows a curvature at a focal spot, and a positional correlation was observed between the cuticle layer thickness and its corresponding cell layer thickness. Adult major eyespots of J. orithya and J. almana exhibited surface elevations and depressions that approximately correspond to the coloration within an eyespot. Our results suggest that a pupal focal spot is produced by the organizing activity of focal cells underneath the focal spot. Probably because the focal cell layer immediately underneath a focal spot is thicker than that of its surrounding areas, eyespots of adult butterfly wings are three-dimensionally constructed. The color-height relationship in adult eyespots might have an implication in the developmental signaling for determining the eyespot color patterns.

  5. Butterfly Wings Are Three-Dimensional: Pupal Cuticle Focal Spots and Their Associated Structures in Junonia Butterflies.

    Directory of Open Access Journals (Sweden)

    Wataru Taira

    Full Text Available Butterfly wing color patterns often contain eyespots, which are developmentally determined at the late larval and early pupal stages by organizing activities of focal cells that can later form eyespot foci. In the pupal stage, the focal position of a future eyespot is often marked by a focal spot, one of the pupal cuticle spots, on the pupal surface. Here, we examined the possible relationships of the pupal focal spots with the underneath pupal wing tissues and with the adult wing eyespots using Junonia butterflies. Large pupal focal spots were found in two species with large adult eyespots, J. orithya and J. almana, whereas only small pupal focal spots were found in a species with small adult eyespots, J. hedonia. The size of five pupal focal spots on a single wing was correlated with the size of the corresponding adult eyespots in J. orithya. A pupal focal spot was a three-dimensional bulge of cuticle surface, and the underside of the major pupal focal spot exhibited a hollowed cuticle in a pupal case. Cross sections of a pupal wing revealed that the cuticle layer shows a curvature at a focal spot, and a positional correlation was observed between the cuticle layer thickness and its corresponding cell layer thickness. Adult major eyespots of J. orithya and J. almana exhibited surface elevations and depressions that approximately correspond to the coloration within an eyespot. Our results suggest that a pupal focal spot is produced by the organizing activity of focal cells underneath the focal spot. Probably because the focal cell layer immediately underneath a focal spot is thicker than that of its surrounding areas, eyespots of adult butterfly wings are three-dimensionally constructed. The color-height relationship in adult eyespots might have an implication in the developmental signaling for determining the eyespot color patterns.

  6. Focal thyroid incidentalomas identified with whole-body FDG-PET warrant further investigation.

    LENUS (Irish Health Repository)

    Prichard, R S

    2012-02-01

    Fluorodeoxyglucose (FDG) whole body positron emission computed tomography (PET-CT) detects clinically occult malignancy. The aim of this study was to assess the prevalence and significance of focal thyroid 18F - fluorodeoxyglucose uptake. A retrospective review of all patients who had FDG PET-CT examinations, in a single tertiary referral centre was performed. PET scan findings and the final pathological diagnosis were collated. 2105 scans were reviewed. Focal uptake was identified in 35 (1.66%) patients. Final surgical histology was available on eight patients, which confirmed papillary carcinoma in four (20%) patients and lymphoma and metastatic disease in two patients respectively. This gave an overall malignancy rate in focal thyroid uptake of at least 33%. Thyroid incidentalomas occurred with a frequency of 2.13%, with an associated malignancy rate of at least 33% in focal thyroid uptake. The high malignancy rate associated with focal thyroid uptake mandates further investigation in medically fit patients.

  7. Intraoperative definition of bottom-of-sulcus dysplasia using intraoperative ultrasound and single depth electrode recording - A technical note.

    Science.gov (United States)

    Miller, Dorothea; Carney, Patrick; Archer, John S; Fitt, Gregory J; Jackson, Graeme D; Bulluss, Kristian J

    2018-02-01

    Bottom of sulcus dysplasias (BOSDs) are localized focal cortical dysplasias (FCDs) centred on the bottom of a sulcus that can be highly epileptogenic, but difficult to delineate intraoperatively. We report on a patient with refractory epilepsy due to a BOSD, successfully resected with the aid of a multimodal surgical approach using neuronavigation based on MRI and PET, intraoperative ultrasound (iUS) and electrocorticography (ECoG) using depth electrodes. The lesion could be visualized on iUS showing an increase in echogenicity at the grey-white matter junction. IUS demonstrated the position of the depth electrode in relation to the lesion. Depth electrode recording showed almost continuous spiking. Thus, intraoperative imaging and electrophysiology helped confirm the exact location of the lesion. Post-resection ultrasound demonstrated the extent of the resection and depth electrode recording did not show any epileptiform activity. Thus, both techniques helped assess completeness of resection. The patient has been seizure free since surgery. Using a multimodal approach including iUS and ECoG is a helpful adjunct in surgery for BOSD and may improve seizure outcome. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Regional cerebral blood flow in focal cortical epilepsy

    DEFF Research Database (Denmark)

    Hougaard, Kristina Dupont; Oikawa, T; Sveinsdottir, E

    1976-01-01

    Regional cerebral blood flow (rCBF) was studied in ten patients with focal cortical epilepsy. The blood flow was measured by the intra-arterial injection of xenon 133 (133Xe), and the isotope clearance was recorded by a multidetector scintillation camera with 254 detectors. Three patients were....... This finding accords with earlier studies. All nine patients studied in the interictal phase showed, either spontaneously or during activation by intermittent light, focal flow increases in areas presumed to comprise the epileptic focus. These interictal hyperemic foci probably reflect subictal neuronal...

  9. On the relationships between electron spot size, focal spot size, and virtual source position in Monte Carlo simulations

    International Nuclear Information System (INIS)

    Sterpin, E.; Chen, Y.; Lu, W.; Mackie, T. R.; Olivera, G. H.; Vynckier, S.

    2011-01-01

    Purpose: Every year, new radiotherapy techniques including stereotactic radiosurgery using linear accelerators give rise to new applications of Monte Carlo (MC) modeling. Accurate modeling requires knowing the size of the electron spot, one of the few parameters to tune in MC models. The resolution of integrated megavoltage imaging systems, such as the tomotherapy system, strongly depends on the photon spot size which is closely related to the electron spot. The aim of this article is to clarify the relationship between the electron spot size and the photon spot size (i.e., the focal spot size) for typical incident electron beam energies and target thicknesses. Methods: Three electron energies (3, 5.5, and 18 MeV), four electron spot sizes (FWHM=0, 0.5, 1, and 1.5 mm), and two tungsten target thicknesses (0.15 and 1 cm) were considered. The formation of the photon beam within the target was analyzed through electron energy deposition with depth, as well as photon production at several phase-space planes placed perpendicular to the beam axis, where only photons recorded for the first time were accounted for. Photon production was considered for ''newborn'' photons intersecting a 45x45 cm 2 plane at the isocenter (85 cm from source). Finally, virtual source position and ''effective'' focal spot size were computed by backprojecting all the photons from the bottom of the target intersecting a 45x45 cm 2 plane. The virtual source position and focal spot size were estimated at the plane position where the latter is minimal. Results: In the relevant case of considering only photons intersecting the 45x45 cm 2 plane, the results unambiguously showed that the effective photon spot is created within the first 0.25 mm of the target and that electron and focal spots may be assumed to be equal within 3-4%. Conclusions: In a good approximation photon spot size equals electron spot size for high energy X-ray treatments delivered by linear accelerators.

  10. Continuous contour phase plates for tailoring the focal plane irradiance profile

    International Nuclear Information System (INIS)

    Dixit, S.N.; Rushford, M.C.; Thomas, I.M.; Perry, M.D.

    1995-01-01

    We present fully continuous phase screens for producing super-Gaussian focal-plane irradiance profiles. Such phase screens are constructed with the assumption of either circular symmetric near-field and far-field profiles or a separable phase screen in Cartesian co-ordinates. In each case, the phase screen is only a few waves deep. Under illumination by coherent light, such phase screens produce high order super-Gaussian profiles in the focal plane with high energy content effects of beam aberrations on the focal profiles and their energy content are also discussed

  11. Characterization of LIL laser UV focal spot

    International Nuclear Information System (INIS)

    Mangeant, M.; Dubois, J.L.; Behar, G.; Arroyo, P.; Durand, V.; Lahonde, C.

    2006-01-01

    One way to get the fusion of hydrogen in laboratory consists in heating and compressing a DT fuel capsule by using a laser. To reach this aim requires a new generation of high power laser facility. Cea (French board for atomic energy) is developing for this purpose a new 240 laser line facility, the LMJ facility. The LIL which is the prototype of four LMJ laser lines is operational now. In order to confirm the technical choices, a systematic characterization of LIL was carried out. A particular effort has been provided to measure the 3ω high energy focal spot (1.5 kJ/700 ps and 5 ns for one beam) and the synchronization of laser beams onto the target, which are key issues for the plasma production. An experimental device, SAT-3ω (a 3ω laser focal spot analysis) has been designed to perform these measures. That diagnostic which is located at the end of the laser lines delivered its first results during the 2004 quadruplet qualification campaigns. The near field imaging showed no diaphony and vignetting. Low power spots allowed us to control we had no ghost. The energy measurement quality showed the photometric transfer function was perfectly known. Our caustic image are given with an average dynamic range of 800, a spatial resolution of 10 μm and diameter accuracy about 1% for 50% and 3% for 90% of encircled energy. The high energy focal spot diameters are in agreement with low and very low energy diameters. The phase plate and 14 GHz effects are similar to what we had expected. For a laser shot completed with a continuous phase plate at 14 GHz, and for an energy level of 1.5 kJ per beam at 351 nm, the focal beam diameter at 3% of the peak level is (875 ± 45) μm

  12. Widespread EEG changes precede focal seizures.

    Directory of Open Access Journals (Sweden)

    Piero Perucca

    Full Text Available The process by which the brain transitions into an epileptic seizure is unknown. In this study, we investigated whether the transition to seizure is associated with changes in brain dynamics detectable in the wideband EEG, and whether differences exist across underlying pathologies. Depth electrode ictal EEG recordings from 40 consecutive patients with pharmacoresistant lesional focal epilepsy were low-pass filtered at 500 Hz and sampled at 2,000 Hz. Predefined EEG sections were selected immediately before (immediate preictal, and 30 seconds before the earliest EEG sign suggestive of seizure activity (baseline. Spectral analysis, visual inspection and discrete wavelet transform were used to detect standard (delta, theta, alpha, beta and gamma and high-frequency bands (ripples and fast ripples. At the group level, each EEG frequency band activity increased significantly from baseline to the immediate preictal section, mostly in a progressive manner and independently of any modification in the state of vigilance. Preictal increases in each frequency band activity were widespread, being observed in the seizure-onset zone and lesional tissue, as well as in remote regions. These changes occurred in all the investigated pathologies (mesial temporal atrophy/sclerosis, local/regional cortical atrophy, and malformations of cortical development, but were more pronounced in mesial temporal atrophy/sclerosis. Our findings indicate that a brain state change with distinctive features, in the form of unidirectional changes across the entire EEG bandwidth, occurs immediately prior to seizure onset. We postulate that these changes might reflect a facilitating state of the brain which enables a susceptible region to generate seizures.

  13. A case of pathological rib fractures: focal osteolysis or osteoporosis?

    Science.gov (United States)

    Vrbanić, T S L; Novak, S; Sestan, B; Tudor, A; Gulan, G

    2008-03-01

    This paper reports on a unique, previously unreported, successful outcome in the case of a patient with focal osteolytic lesions of the ribs as a first sign of osteoporosis. The lesions were detected by chance after acute cough-induced rib fractures were seen on plain chest radiographs. The diagnosis had to be approached as a diagnosis of exclusion since known causes of the osteolytic process had to be eliminated. The authors describe multiple focal osteolytic lesions with rib fractures appearing in a pattern that could be confused with metastases. Laboratory results were normal. Final diagnosis was based on plain radiography, bone scan and bone densitometry. Pharmacomedical treatments for osteoporosis were applied. The patient was observed between the year 2000 and 2005. Five years later radiological and bone scintigraphy revealed resolution of the lesion. We conclude that osteoporosis should be included in the differential diagnosis of asymptomatic focal osteolysis of the ribs with rib fractures as a complication of acute cough. The case suggests that focal osteolytic lesions of the ribs may regress over time and become scintigraphically inactive.

  14. 3 Tesla MRI-negative focal epilepsies: Presurgical evaluation, postoperative outcome and predictive factors.

    Science.gov (United States)

    Kogias, Evangelos; Klingler, Jan-Helge; Urbach, Horst; Scheiwe, Christian; Schmeiser, Barbara; Doostkam, Soroush; Zentner, Josef; Altenmüller, Dirk-Matthias

    2017-12-01

    To investigate presurgical diagnostic modalities, clinical and seizure outcome as well as predictive factors after resective epilepsy surgery in 3 Tesla MRI-negative focal epilepsies. This retrospective study comprises 26 patients (11 males/15 females, mean age 34±12years, range 13-50 years) with 3 Tesla MRI-negative focal epilepsies who underwent resective epilepsy surgery. Non-invasive and invasive presurgical diagnostic modalities, type and localization of resection, clinical and epileptological outcome with a minimum follow-up of 1year (range 1-11 years, mean 2.5±2.3years) after surgery as well as outcome predictors were evaluated. All patients underwent invasive video-EEG monitoring after implantation of intracerebral depth and/or subdural electrodes. Ten patients received temporal and 16 extratemporal or multilobar (n=4) resections. There was no perioperative death or permanent morbidity. Overall, 12 of 26 patients (46%) were completely seizure-free (Engel IA) and 65% had a favorable outcome (Engel I-II). In particular, seizure-free ratio was 40% in the temporal and 50% in the extratemporal group. In the temporal group, long duration of epilepsy correlated with poor seizure outcome, whereas congruent unilateral FDG-PET hypometabolism correlated with a favorable outcome. In almost two thirds of temporal and extratemporal epilepsies defined as "non-lesional" by 3 Tesla MRI criteria, a favorable postoperative seizure outcome (Engel I-II) can be achieved with accurate multimodal presurgical evaluation including intracranial EEG recordings. In the temporal group, most favorable results were obtained when FDG-PET displayed congruent unilateral hypometabolism. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Simulation of the Focal Spot of the Accelerator Bremsstrahlung Radiation

    Science.gov (United States)

    Sorokin, V.; Bespalov, V.

    2016-06-01

    Testing of thick-walled objects by bremsstrahlung radiation (BR) is primarily performed via high-energy quanta. The testing parameters are specified by the focal spot size of the high-energy bremsstrahlung radiation. In determining the focal spot size, the high- energy BR portion cannot be experimentally separated from the low-energy BR to use high- energy quanta only. The patterns of BR focal spot formation have been investigated via statistical modeling of the radiation transfer in the target material. The distributions of BR quanta emitted by the target for different energies and emission angles under normal distribution of the accelerated electrons bombarding the target have been obtained, and the ratio of the distribution parameters has been determined.

  16. Focal adhesions and cell-matrix interactions

    DEFF Research Database (Denmark)

    Woods, A; Couchman, J R

    1988-01-01

    Focal adhesions are areas of cell surfaces where specializations of cytoskeletal, membrane and extracellular components combine to produce stable cell-matrix interactions. The morphology of these adhesions and the components identified in them are discussed together with possible mechanisms...

  17. Radiopneumographic characteristics of focal pneumonia in children

    International Nuclear Information System (INIS)

    Smirnova, A.A.

    1980-01-01

    Zonal ventilation and blood flow were studied by the radiopneumography method in 50 children of school age with lower-lobe-of-the lung focal pneumonia (26 with left-side and 24 with right-side). It is established that during right-side localization of pneumonic focus preserved was the predomination of ventilation of right lung relative to left. Complete normalization of common and regional indexes of ventilation and blood flow was established by the 21st day from the beginning of treatment during right-side focal pneumonias. In case of left-side localization of pneumonic focus only partial reduction of external respiration and perfusion comes. Therefore, compensatory and reducing capabilities of right lung are preferrable

  18. Flux dynamics in ultrasensitive superconducting focal planes

    Data.gov (United States)

    National Aeronautics and Space Administration — The performance of superconducting focal planes will drive the achievable specifications of ultrasensitive instruments for NASA astrophysics missions, yet they have...

  19. Sowing Depth Effects on Vetch Yield in Maragheh Dry Lands

    Directory of Open Access Journals (Sweden)

    J Asghari Meidany

    2013-12-01

    Full Text Available Increases forage production and economic production in rainfed condition requires attention to agricultural issues such as determination of appropriate sowing depth. So in order to determine the effect of different sowing depths of vetch this experiment was conducted in Agricultural Research Station of Maragheh as strip plot based on randomized complete block design with three species of vetch V. sativa , V. dasycarpa-kouhak and V. narbonensis velox67 as main plots and three sowing depth as sub factor. Results showed that the effect of sowing depth on Vicia yield was significant at the 1% level and the maximum yield of wet hay, dry hay, straw and seed depth of belong to 8-10 cm depth and respectively are 5.364, 3.416, 4.389 and 1.081 ton per ha whereas the minimum yield of wet hay, dry hay, straw and seed depth of belong to 2-4 cm depth and respectively are 4.888, 2.318, 3.729 and 0.825. Among the three Vicia species the highest yield of wet hay, dry hay , straw and seed belongs to V. dasykarpa and respectively are 5.632, 3.532, 4.614 and 1.065 ton/ha. Soil moisture study in the field of these vetches at the time of 10 % vetch flowering showed water differences. V.dasycarpa had lower water depletion from soil. The amount of average soil water for species included: V. dasycarpa 26.31, V. sativa 23.76 and V. narbonesis 22.5.

  20. Focal adhesion kinase-dependent focal adhesion recruitment of SH2 domains directs SRC into focal adhesions to regulate cell adhesion and migration.

    Science.gov (United States)

    Wu, Jui-Chung; Chen, Yu-Chen; Kuo, Chih-Ting; Wenshin Yu, Helen; Chen, Yin-Quan; Chiou, Arthur; Kuo, Jean-Cheng

    2015-12-18

    Directed cell migration requires dynamical control of the protein complex within focal adhesions (FAs) and this control is regulated by signaling events involving tyrosine phosphorylation. We screened the SH2 domains present in tyrosine-specific kinases and phosphatases found within FAs, including SRC, SHP1 and SHP2, and examined whether these enzymes transiently target FAs via their SH2 domains. We found that the SRC_SH2 domain and the SHP2_N-SH2 domain are associated with FAs, but only the SRC_SH2 domain is able to be regulated by focal adhesion kinase (FAK). The FAK-dependent association of the SRC_SH2 domain is necessary and sufficient for SRC FA targeting. When the targeting of SRC into FAs is inhibited, there is significant suppression of SRC-mediated phosphorylation of paxillin and FAK; this results in an inhibition of FA formation and maturation and a reduction in cell migration. This study reveals an association between FAs and the SRC_SH2 domain as well as between FAs and the SHP2_N-SH2 domains. This supports the hypothesis that the FAK-regulated SRC_SH2 domain plays an important role in directing SRC into FAs and that this SRC-mediated FA signaling drives cell migration.

  1. Production of high energy, uniform focal profiles with the Nike laser

    Science.gov (United States)

    Lehecka, T.; Lehmberg, R. H.; Deniz, A. V.; Gerber, K. A.; Obenschain, S. P.; Pawley, C. J.; Pronko, M. S.; Sullivan, C. A.

    1995-02-01

    Nike, a KrF laser facility at the Naval Research Laboratory, is designed to produce high intensity, ultra-uniform focal profiles for experiments relating to direct drive inertial confinement fusion. We present measurements of focal profiles through the next-to-last amplifier, a 20 × 20 cm 2 aperture electron beam pumped amplifier capable of producing more than 120 J of output in a 120 ns pulse. Using echelon free induced spatial incoherence beam smoothing this system has produced focal profiles with less than 2% tilt and curvature and less than 2% rms variation from a flat top distribution.

  2. Modulation depth analysis in fast pulsations of solar radio emission

    International Nuclear Information System (INIS)

    Chernov, G.P.; Kurts, Yu.; Akademie der Wissenschaften der DDR, Berlin

    1990-01-01

    A model of millisecond pulsations due to a pulsation regime of a whistler spectrum is confirmed by the statistical analysis of the modulation depth in five type IV bursts; a modulation depth distribution ΔI/I versus the period (p) grows linearly (with the different slope) up to the maximum at the value ΔI/I ≅ 0.5-0.6. The same dependence ΔI/I(p) for spikes, observed during the same events, testifies also in favour of this model. The overlap on fast pulsations of fiber bursts and of sudden reductions are displayed in the ΔI/I(p) distribution by diffuse tails which are naturally explained by the known models of this fine structure

  3. Adult-onset Rasmussen encephalitis associated with focal cortical dysplasia.

    Science.gov (United States)

    Hohenbichler, Katharina; Lelotte, Julie; Lhommel, Renaud; Tahry, Riëm El; Vrielynck, Pascal; Santos, Susana Ferrao

    2017-12-01

    Rasmussen encephalitis is a rare, devastating condition, typically presenting in childhood. Cases of adult-onset Rasmussen have also been described, but the clinical picture is less defined, rendering final diagnosis difficult. We present a case of adult-onset Rasmussen encephalitis with dual pathology, associated with focal cortical dysplasia and encephalitis. We interpreted the Rasmussen encephalitis to be caused by severe and continuous epileptic activity due to focal cortical dysplasia. The best therapeutic approach for such cases remains unclear.

  4. Focal cryotherapy of localized prostate cancer: a systematic review of the literature.

    Science.gov (United States)

    Shah, Taimur Tariq; Ahmed, Hashim; Kanthabalan, Abi; Lau, Benjamin; Ghei, Maneesh; Maraj, Barry; Arya, Manit

    2014-11-01

    Radical/whole gland treatment for prostate cancer has significant side-effects. Therefore focal treatments such as cryotherapy have been used to treat localized lesions whilst aiming to provide adequate cancer control with minimal side-effects. We performed a systematic review of Pubmed/Medline and Cochrane databases' to yield 9 papers for primary focal prostate cryotherapy and 2 papers for focal salvage treatment (radio-recurrent). The results of 1582 primary patients showed biochemical disease-free survival between 71-93% at 9-70 months follow-up. Incontinence rates were 0-3.6% and ED 0-42%. Recto-urethral fistula occurred in only 2 patients. Salvage focal cryotherapy had biochemical disease-free survival of 50-68% at 3 years. ED occurred in 60-71%. Focal cryotherapy appears to be an effective treatment for primary localized prostate cancer and compares favorably to radical/whole gland treatments in medium-term oncological outcomes and side-effects. Although more studies are needed it is also effective for radio-recurrent cancer with a low complications rates.

  5. Spreading of focal brain edema induced by ultraviolet irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ferszt, R; Neu, S; Cervos-Navarro, J; Sperner, J [Freie Univ. Berlin (Germany, F.R.). Inst. fuer Neuropathologie

    1978-01-01

    Focal brain edema limited to one cerebral hemisphere was produced by ultraviolet irradiation of the exposed cortex. Tissue water content was determined by the gravimetric method which allows microsampling. Therefore, the spread of edema around the small necrotic area be mapped more precisely than by determination of dry weight which calls for larger samples. As early as 30 min after irradiation, hyperemia and swelling of the brain are observed under the operating microscope. This correlates with venous stasis, hyperemia, and broadened perivascular spaces around venules and large capillaries accompanied by a marked rise in the specific weigth of the tissue. After 4h an edema front can be observed spreading from the perinerotic zone in which there is a marked rise in endothelial cell vesicular activity. Edema reaches maximum levels in the deep white matter at 48h post irradiation with normalisation of the tissue water content after 96h. The velocity at which the edema front spreads from the cortex to the periventricular area lies in the range of 0.25mm/h. Edema reabsorption coincides with signs of retrograde micropinocytosis in endothelial cells.

  6. Factores pronósticos de recurrencia de la epilepsia focal en el niño Prognostic factors of recurrence of focal epilepsy in children

    Directory of Open Access Journals (Sweden)

    Albia Pozo Alonso

    2009-12-01

    Full Text Available INTRODUCCIÓN. El objetivo de este trabajo fue determinar los factores pronósticos de recurrencia de las crisis epilépticas focales a los 2 años del diagnóstico y del inicio del tratamiento. MÉTODOS. Este estudio observacional, analítico y prospectivo incluyó a 207 niños que presentaron dos o más crisis epilépticas focales no provocadas, hospitalizados en el Departamento de Neuropediatría del Hospital «William Soler», entre diciembre de 2001 y diciembre de 2003. Al final de los 2 años de seguimiento, 185 pacientes concluyeron el estudio. RESULTADOS. El 33,5 % de los pacientes presentó recurrencias de las crisis epilépticas focales al finalizar el estudio. Constituyeron factores de riesgo de recurrencia de las crisis epilépticas focales los siguientes: edad menor de un año, etiología sintomática, presencia de antecedentes personales de crisis neonatales sintomáticas y discapacidades neurológicas y la persistencia de descargas en el electroencefalograma (EEG evolutivo. El análisis de regresión logística demostró como variables pronósticas de recurrencia la etiología sintomática (p = 0,000; OR = 3,107, el antecedente personal de crisis neonatales sintomáticas (p = 0,037; OR = 4,623 y la persistencia de descargas en el EEG evolutivo (p = 0,000; OR = 2,109. CONCLUSIONES. El antecedente personal de crisis neonatales sintomáticas constituyó el factor independiente con mayor influencia en las recurrencias de las crisis epilépticas focales.INTRODUCTION: The objective of present paper was to determine the recurrent prognostic factors of focal epileptic crises at 2 years of diagnosis and of treatment onset. METHODS: This prospective, analytical and observational study included 207 children presenting two or more non-provoked epileptic crises, admitted in Neuropediatrics Department of "William Soler" Hospital between December, 2001 and December, 2003. At a two years follow-up, 185 patients concluded the study. RESULTS: The

  7. Focal plane for the next generation of earth observation instruments

    Science.gov (United States)

    Pranyies, P.; Toubhans, I.; Badoil, B.; Tanguy, F.; Descours, Francis

    2017-09-01

    Sodern is the French focal plane provider for Earth Observation (EO) satellites. Since the 1980's, Sodern has played an active role first in the SPOT program. Within the two-spacecraft constellation Pleiades 1A/1B over the next years, Sodern introduced advanced technologies as Silicon Carbide (SiC) focal plane structure and multispectral strip filters dedicated to multiple-lines detectors.

  8. Magnetic-resonance-guided biopsy of focal liver lesions

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Ethan A. [University of Michigan Health System, Section of Pediatric Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Grove, Jason J. [University of Michigan Health System, Division of Interventional Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Der Spek, Abraham F.L.V. [University of Michigan Health System, Department of Anesthesiology, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States); Jarboe, Marcus D. [University of Michigan Health System, Division of Interventional Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); University of Michigan Health System, Section of Pediatric Surgery, C.S. Mott Children' s Hospital, Department of Surgery, Ann Arbor, MI (United States)

    2017-05-15

    Image-guided biopsy techniques are widely used in clinical practice. Commonly used methods employ either ultrasound (US) or computed tomography (CT) for image guidance. In certain patients, US or CT guidance may be suboptimal, or even impossible, because of artifacts, suboptimal lesion visualization, or both. We recently began performing magnetic resonance (MR)-guided biopsy of focal liver lesions in select pediatric patients with lesions that are not well visualized by US or CT. This report describes our experience performing MR-guided biopsy of focal liver lesions, with case examples to illustrate innovative techniques and novel aspects of these procedures. (orig.)

  9. Evaluation of depth of field in SEM images in terms of the information-passing capacity (IPC) and contrast gradient in SEM image

    International Nuclear Information System (INIS)

    Sato, Mitsugu; Ishitani, Tohru; Watanabe, Shunya; Nakagawa, Mine

    2004-01-01

    The depth of field (DoF) in scanning electron microscope (SEM) images has been determined by estimating the change of image sharpness or resolution near the exact focus position. The image sharpness or resolution along the optical axis is determined by calculating the information-passing capacity (IPC) of an optical system taking into account the effect of pixel size of the image. The change of image sharpness near the exact focus position is determined by measuring the slope gradient of the line profile in SEM images obtained at various focal positions of beam. The change of image sharpness along the optical axis determined by the IPC agrees well with those determined by the slope gradient of line profiles in SEM images when a Gaussian distribution having radius 0.86L p (L p : pixel size in image) at which the intensity has fallen to 1/e of the maximum is applied to the IPC calculation for each pixel intensity. The change of image sharpness near the exact focus position has also been compared with those determined by the CG (Contrast-to-Gradient) method. The CG method slightly underestimates the change of image sharpness compared with those determined by the IPC method

  10. 99mTc-HM-PAO SPECT of epileptic patients showing focal paroxysm on electroencephalography

    International Nuclear Information System (INIS)

    Takaishi, Yasuko; Hashimoto, Kiyoshi; Fujino, Osamu; Kamayachi, Satoshi; Fujita, Takehisa; Enokido, Hisashi; Komatsuzaki, Hideki; Kawakami, Yasuhiko; Hirayama, Tsunenori

    1995-01-01

    The usefulness of 99m Tc-HM-PAO SPECT in diagnosing epilepsy was studied. The subjects were 33 epileptic patients, ranging in age from 5 years and 5 months to 28 years and 3 months, who showed focal paroxysm on electroencephalograms. Lowered accumulation site was found on SPECT in 19 patients. Four patients with abnormal findings on X-ray CT or MRI showed lowered accumulation and focal paroxysm at the same site. Of 29 patients with normal X-ray CT or MRI findings, 15 (52%) showed lowered accumulation. Five patients showed a focal paroxysm at the site of lowered accumulation. In 8 patients the focal paroxysm site was partly coincided with the accumulation site. In some patients the focal site predicted by the findings of clinical symptoms and the lowered accumulation site coincided. SPECT is therefore a useful method in diagnosing a focal site in epilepsy and considered to reflect the severity of disease. (Y.S.)

  11. Measuring the Flatness of Focal Plane for Very Large Mosaic CCD Camera

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Jiangang; Estrada, Juan; Cease, Herman; Diehl, H.Thomas; Flaugher, Brenna L.; Kubik, Donna; Kuk, Keivin; Kuropatkine, Nickolai; Lin, Huan; Montes, Jorge; Scarpine, Vic; /Fermilab

    2010-06-08

    Large mosaic multiCCD camera is the key instrument for modern digital sky survey. DECam is an extremely red sensitive 520 Megapixel camera designed for the incoming Dark Energy Survey (DES). It is consist of sixty two 4k x 2k and twelve 2k x 2k 250-micron thick fully-depleted CCDs, with a focal plane of 44 cm in diameter and a field of view of 2.2 square degree. It will be attached to the Blanco 4-meter telescope at CTIO. The DES will cover 5000 square-degrees of the southern galactic cap in 5 color bands (g, r, i, z, Y) in 5 years starting from 2011. To achieve the science goal of constraining the Dark Energy evolution, stringent requirements are laid down for the design of DECam. Among them, the flatness of the focal plane needs to be controlled within a 60-micron envelope in order to achieve the specified PSF variation limit. It is very challenging to measure the flatness of the focal plane to such precision when it is placed in a high vacuum dewar at 173 K. We developed two image based techniques to measure the flatness of the focal plane. By imaging a regular grid of dots on the focal plane, the CCD offset along the optical axis is converted to the variation the grid spacings at different positions on the focal plane. After extracting the patterns and comparing the change in spacings, we can measure the flatness to high precision. In method 1, the regular dots are kept in high sub micron precision and cover the whole focal plane. In method 2, no high precision for the grid is required. Instead, we use a precise XY stage moves the pattern across the whole focal plane and comparing the variations of the spacing when it is imaged by different CCDs. Simulation and real measurements show that the two methods work very well for our purpose, and are in good agreement with the direct optical measurements.

  12. Focal masses in a non-cirrhotic liver: The additional benefit of CEUS over baseline imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chiorean, L., E-mail: lilichiorean@yahoo.com [Sino-German Research Center of Ultrasound in Medicine, The First Affiliated Hospital of Zhengzhou University (China); Med. Klinik 2, Caritas Krankenhaus Bad Mergentheim, Uhlandstr. 7, D-97980 Bad Mergentheim (Germany); Département d’imagerie médicale, Clinique des Cévennes, 07100 Annonay (France); Cantisani, V., E-mail: vito.cantisani@uniroma1.it [Dipartimento di Scienze Radiologiche, Oncologiche, Anatomo-patologiche, Policlinico Umberto I, Univ. Sapienza, Roma (Italy); Jenssen, C., E-mail: C.Jenssen@khmol.de [Innere Medizin, Krankenhaus Märkisch Oderland, Prötzeler Chaussee 5, 15433 Strausberg (Germany); Sidhu, P.S., E-mail: paulsidhu@nhs.net [Department of Radiology, King' s College Hospital, Denmark Hill, London SE5 9RS, England (United Kingdom); Baum, U., E-mail: Ulrich.Baum@ckbm.de [Department of Radiology, Caritas Krankenhaus Bad Mergentheim, Uhlandstr. 7, D-97980 Bad Mergentheim (Germany); Dietrich, C.F., E-mail: christoph.dietrich@ckbm.de [Sino-German Research Center of Ultrasound in Medicine, The First Affiliated Hospital of Zhengzhou University (China); Med. Klinik 2, Caritas Krankenhaus Bad Mergentheim, Uhlandstr. 7, D-97980 Bad Mergentheim (Germany)

    2015-09-15

    Highlights: • Contrast-enhanced ultrasound in detection of focal liver lesions. • Contrast-enhanced ultrasound in characterization of focal liver lesions. • Contrast-enhanced ultrasound in differential diagnosis of focal liver lesions. • Contrast-enhanced ultrasound in final diagnosis of focal liver lesions. • Contrast-enhanced ultrasound in liver metastases screening. • Roles of cross-sectional imaging techniques for focal liver lesions assessment. • Advantages of contrast-enhanced ultrasound over other imaging procedures. - Abstract: Incidentally detected focal liver lesions are commonly encountered in clinical practice presenting a challenge in the daily department work flow. Guidelines for the management of incidental focal liver lesions have been published but comments, illustrations and recommendations regarding practical issues are crucial. The unique features of contrast-enhanced ultrasound in non-invasive assessment of focal liver lesion enhancement throughout the vascular phases in real-time has allowed an impressive improvement in the diagnostic accuracy of ultrasound. We highlight the additional benefit of contrast-enhanced ultrasound over conventional B-mode ultrasound imaging in detection, characterization, differential and final diagnosis of focal liver lesions, as well as for liver metastases screening. The current roles of cross-sectional imaging are explained in detail, with indications and limitations for each procedure. The advantages of CEUS, such as non-ionizing radiation exposure, cost benefits, non-iodinate contrast agents, and repeatability are also described ultimately improving patient management.

  13. Focal shift and faculae dimension of focused flat beam propagating in turbulent atmosphere

    International Nuclear Information System (INIS)

    Zhang Jianzhu; Li Youkuan; Zhang Feizhou; An Jianzhu

    2011-01-01

    Through theoretic analysis and numerical simulation,the focal shift of a focused flat beam propagating in turbulent atmosphere is studied. When a focused flat beam propagates in turbulent atmosphere, the effect of turbulence will induce the focal spot to move toward the transmitter. The turbulence is stronger and the diameter of transmitter is smaller, the measure of focal shift is larger. When adjusting the focus of transmitter and letting the focal spot of beam locate on detector, the laser intensity received by detector is not the strongest. The laser intensity will be the strongest if the focus of transmitter equals to the distance from transmitter to detector. (authors)

  14. Collusion through Price Ceilings? In Search of a Focal-Point Effect

    NARCIS (Netherlands)

    Engelmann, D.; Müller, W.

    2008-01-01

    With this study we resume the search for a collusive focal-point effect of price ceilings in laboratory markets. We argue that market conditions in previous studies were unfavorable for collusion which may have been responsible for not finding such a focal-point effect. Our design aims at maximizing

  15. Collusion through price ceilings? In search of a focal-point effect

    NARCIS (Netherlands)

    Engelmann, D.; Müller, W.

    2011-01-01

    We resume the search for a collusive focal-point effect of price ceilings in laboratory markets. We argue that market conditions in previous studies were unfavorable for collusion which may have been responsible for not finding such a focal-point effect. Our design aims at maximizing the likelihood

  16. Variations in the size of focal nodular hyperplasia on magnetic resonance imaging.

    Science.gov (United States)

    Ramírez-Fuentes, C; Martí-Bonmatí, L; Torregrosa, A; Del Val, A; Martínez, C

    2013-01-01

    To evaluate the changes in the size of focal nodular hyperplasia (FNH) during long-term magnetic resonance imaging (MRI) follow-up. We reviewed 44 FNHs in 30 patients studied with MRI with at least two MRI studies at least 12 months apart. We measured the largest diameter of the lesion (inmm) in contrast-enhanced axial images and calculated the percentage of variation as the difference between the maximum diameter in the follow-up and the maximum diameter in the initial study. We defined significant variation in size as variation greater than 20%. We also analyzed predisposing hormonal factors. The mean interval between the two imaging studies was 35±2 months (range: 12-94). Most lesions (80%) remained stable during follow-up. Only 9 of the 44 lesions (20%) showed a significant variation in diameter: 7 (16%) decreased in size and 2 (4%) increased, with variations that reached the double of the initial size. The change in size was not related to pregnancy, menopause, or the use of birth control pills or corticoids. Changes in the size of FNHs during follow-up are relatively common and should not lead to a change in the diagnosis. These variations in size seem to be independent of hormonal factors that are considered to predispose. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  17. Genetic Algorithm for Opto-thermal Skin Hydration Depth Profiling Measurements

    Science.gov (United States)

    Cui, Y.; Xiao, Perry; Imhof, R. E.

    2013-09-01

    Stratum corneum is the outermost skin layer, and the water content in stratum corneum plays a key role in skin cosmetic properties as well as skin barrier functions. However, to measure the water content, especially the water concentration depth profile, within stratum corneum is very difficult. Opto-thermal emission radiometry, or OTTER, is a promising technique that can be used for such measurements. In this paper, a study on stratum corneum hydration depth profiling by using a genetic algorithm (GA) is presented. The pros and cons of a GA compared against other inverse algorithms such as neural networks, maximum entropy, conjugate gradient, and singular value decomposition will be discussed first. Then, it will be shown how to use existing knowledge to optimize a GA for analyzing the opto-thermal signals. Finally, these latest GA results on hydration depth profiling of stratum corneum under different conditions, as well as on the penetration profiles of externally applied solvents, will be shown.

  18. Predicting scour beneath subsea pipelines from existing small free span depths under steady currents

    Directory of Open Access Journals (Sweden)

    Jun Y. Lee

    2017-06-01

    Full Text Available An equation was developed to predict current-induced scour beneath subsea pipelines in areas with small span depths, S. Current equations for scour prediction are only applicable to partially buried pipelines. The existence of small span depths (i.e. S/D < 0.3 are of concern because the capacity for scour is higher at smaller span depths. Furthermore, it is impractical to perform rectification works, such as installing grout bags, under a pipeline with a small S/D. Full-scale two-dimensional computational fluid dynamics (CFD simulations were performed using the Reynolds-averaged Navier–Stokes approach and the Shear stress transport k–ω turbulence model. To predict the occurrence of scour, the computed maximum bed shear stress beneath the pipe was converted to the dimensionless Shields parameter, and compared with the critical Shields parameter based on the mean sediment grain size. The numerical setup was verified, and a good agreement was found between model-scale CFD data and experimental data. Field data were obtained to determine the mean grain size, far field current velocity and to measure the span depths along the surveyed pipe length. A trend line equation was fitted to the full-scale CFD data, whereby the maximum Shields parameter beneath the pipe can be calculated based on the undisturbed Shields parameter and S/D.

  19. Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm

    International Nuclear Information System (INIS)

    Bloch, P.; Altschuler, M.D.; Bjaerngard, B.E.; Kassaee, A.; McDonough, J.

    2000-01-01

    A method to determine the spectrum of a clinical photon beam from measured depth-dose data is described. At shallow depths, where the range of Compton-generated electrons increases rapidly with photon energy, the depth dose provides the information to discriminate the spectral contributions. To minimize the influence of contaminating electrons, small (6x6cm2 ) fields were used. The measured depth dose is represented as a linear combination of basis functions, namely the depth doses of monoenergetic photon beams derived by Monte Carlo simulations. The weights of the basis functions were obtained with the Cimmino feasibility algorithm, which examines in each iteration the discrepancy between predicted and measured depth dose. For 6 and 15 MV photon beams of a clinical accelerator, the depth dose obtained from the derived spectral weights was within about 1% of the measured depth dose at all depths. Because the problem is ill conditioned, solutions for the spectrum can fluctuate with energy. Physically realistic smooth spectra for these photon beams appeared when a small margin (about ±1%) was attributed to the measured depth dose. The maximum energy of both derived spectra agreed with the measured energy of the electrons striking the target to within 1 MeV. The use of a feasibility method on minimally relaxed constraints provides realistic spectra quickly and interactively. (author)

  20. Mechanical solution of the maximum point of dynamic abutment pressure under deep long-wall working face

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, F.; Ma, Q. [Shandong University of Science and Technology, Tai' an (China). College of Resource and Environmental Engineering

    2002-06-01

    The paper studies the dynamic relationship between abutment pressure and overburden collapse precess with advancing of working face. The result shows that the abutment pressure reaches its maximum value when the working face dimension is 1.27 times of the mining depth. This result confirms the statistical result from the strata movement surveys that overburden reaches its full movement stage when extracting dimension reaches 1.2 1.4 times of the mining depth. 12 refs., 2 figs.

  1. [A case of focal epilepsy manifesting multiple psychiatric auras].

    Science.gov (United States)

    Ezura, Michinori; Kakisaka, Yosuke; Jin, Kazutaka; Kato, Kazuhiro; Iwasaki, Masaki; Fujikawa, Mayu; Aoki, Masashi; Nakasato, Nobukazu

    2015-01-01

    We present a case of epilepsy with multiple types of focal seizures that were misdiagnosed as psychiatric disorders. A 20-year-old female patient presented with a variety of episodes, including loss of consciousness, deja vu, fear, delusion of possession, violent movements, and generalized convulsions. Each of these symptoms appeared in a stereotypic manner. She was initially diagnosed with a psychiatric disorder and treated with psychoactive medications, which had no effect. Long-term video electroencephalography revealed that her episodes of violent movement with impaired consciousness and secondarily generalized seizure were epileptic events originating in the right hemisphere. High-field brain magnetic resonance imaging for detecting subtle lesions revealed bilateral lesions from periventricular nodular heterotopia. Her final diagnosis was right hemispheric focal epilepsy. Carbamazepine administration was started, which successfully controlled all seizures. The present case demonstrates the pitfall of diagnosing focal epilepsy when it presents with multiple types of psychiatric aura. Epilepsy should thus be included in differential diagnoses, considering the stereotypic nature of symptoms, to avoid misdiagnosis.

  2. Focal hepatic lesions with peripheral eosinophilia: imaging features of various disease

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Joon Beom; Han, Joon Koo; Kim, Tae Kyoung; Choi, Byung Ihn; Han, Man Chung [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of); Song, Chi Sung [Seoul City Boramae Hospital, Seoul (Korea, Republic of)

    1999-01-01

    Due to the recent advent of various imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging, as well as knowledge of the characteristic imaging features of hepatic lesions, radiologic examination plays a major role in the differential diagnosis of focal hepatic lesions. However, various 'nonspecific' or 'unusual' imaging features of focal hepatic lesions are occasionally encountered, and this makes correct diagnosis difficult. In such a situation, the presence of peripheral eosinophilia helps narrow the differential diagnoses. The aim of this pictorial essay is to describe the imaging features of various disease entities which cause focal hepatic lesions and peripheral eosinophilia.

  3. Numerical simulation of permafrost depth during a future glaciation, Campine area, Northern Belgium

    International Nuclear Information System (INIS)

    Govaerts, Joan; Weetjens, Eef; Beerten, Koen

    2012-01-01

    Document available in extended abstract form only. Given the long time frames involved and their potential detrimental effects, climate changes are considered in the safety assessment of long-term geological disposal of radioactive waste. One such effect that climate changes may govern is the re-appearance of permafrost in north-western Europe. This condition already existed during previous glaciations (e.g., Weichselian glacial, 115-11 ka BP), and may have several consequences for the hydrosphere, geosphere, biosphere and repository. Here, we present calculations of permafrost depth based on the climatic scenario with the Weichselian (last glacial) as an analog to estimate the permafrost depth during a future glaciation. Whereas the lateral extent of permafrost can be deduced from surface features, not much is known about the maximum depth of permafrost during a cold stage in the Campine region. Realistic values of the latent heat of melting of pure water, and thermal conductivity of dry or frozen and unfrozen saturated sand and clay are used as input parameters. In addition, detailed and refined climatic scenarios for the last glacial are used to improve the quality of boundary conditions, together with a more advanced description of freezing/thawing processes. To describe heat transport in the subsoil of the Mol site, the one-dimensional enthalpy conservation equation is used with heat transport only occurring by conduction. In the first calculation case, the temperature at the top of the soil layer is set equal to the air temperatures of a realistic glacial cycle (Weichselian glaciation). In a second calculation case, the insulating effects of the surface cover are considered, and the air temperatures are converted into surface temperatures by making use of the 'n-factor concept', which yields an empirical relationship between the mean annual surface temperature, T s , and the mean annual air temperature, T a . In Figure 1 the permafrost pro-gradation front

  4. High permeability cores to optimize the stimulation of deeply located brain regions using transcranial magnetic stimulation

    International Nuclear Information System (INIS)

    Salvador, R; Miranda, P C; Roth, Y; Zangen, A

    2009-01-01

    Efficient stimulation of deeply located brain regions with transcranial magnetic stimulation (TMS) poses many challenges, arising from the fact that the induced field decays rapidly and becomes less focal with depth. We propose a new method to improve the efficiency of TMS of deep brain regions that combines high permeability cores, to increase focality and field intensity, with a coil specifically designed to induce a field that decays slowly with increasing depth. The performance of the proposed design was investigated using the finite element method to determine the total electric field induced by this coil/core arrangement on a realistically shaped homogeneous head model. The calculations show that the inclusion of the cores increases the field's magnitude by as much as 25% while also decreasing the field's decay with depth along specific directions. The focality, as measured by the area where the field's norm is greater than 1/√2 of its maximum value, is also improved by as much as 15% with some core arrangements. The coil's inductance is not significantly increased by the cores. These results show that the presence of the cores might make this specially designed coil even more suited for the effective stimulation of deep brain regions.

  5. High permeability cores to optimize the stimulation of deeply located brain regions using transcranial magnetic stimulation

    Science.gov (United States)

    Salvador, R.; Miranda, P. C.; Roth, Y.; Zangen, A.

    2009-05-01

    Efficient stimulation of deeply located brain regions with transcranial magnetic stimulation (TMS) poses many challenges, arising from the fact that the induced field decays rapidly and becomes less focal with depth. We propose a new method to improve the efficiency of TMS of deep brain regions that combines high permeability cores, to increase focality and field intensity, with a coil specifically designed to induce a field that decays slowly with increasing depth. The performance of the proposed design was investigated using the finite element method to determine the total electric field induced by this coil/core arrangement on a realistically shaped homogeneous head model. The calculations show that the inclusion of the cores increases the field's magnitude by as much as 25% while also decreasing the field's decay with depth along specific directions. The focality, as measured by the area where the field's norm is greater than 1/\\sqrt 2 of its maximum value, is also improved by as much as 15% with some core arrangements. The coil's inductance is not significantly increased by the cores. These results show that the presence of the cores might make this specially designed coil even more suited for the effective stimulation of deep brain regions.

  6. High permeability cores to optimize the stimulation of deeply located brain regions using transcranial magnetic stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Salvador, R; Miranda, P C [Institute of Biophysics and Biomedical Engineering, Faculty of Sciences, University of Lisbon, 1749-016 Lisbon (Portugal); Roth, Y [Advanced Technology Center, Sheba Medical Center, Tel-Hashomer (Israel); Zangen, A [Neurobiology Department, Weizmann Institute of Science, Rehovot 76100 (Israel)], E-mail: rnsalvador@fc.ul.pt

    2009-05-21

    Efficient stimulation of deeply located brain regions with transcranial magnetic stimulation (TMS) poses many challenges, arising from the fact that the induced field decays rapidly and becomes less focal with depth. We propose a new method to improve the efficiency of TMS of deep brain regions that combines high permeability cores, to increase focality and field intensity, with a coil specifically designed to induce a field that decays slowly with increasing depth. The performance of the proposed design was investigated using the finite element method to determine the total electric field induced by this coil/core arrangement on a realistically shaped homogeneous head model. The calculations show that the inclusion of the cores increases the field's magnitude by as much as 25% while also decreasing the field's decay with depth along specific directions. The focality, as measured by the area where the field's norm is greater than 1/{radical}2 of its maximum value, is also improved by as much as 15% with some core arrangements. The coil's inductance is not significantly increased by the cores. These results show that the presence of the cores might make this specially designed coil even more suited for the effective stimulation of deep brain regions.

  7. The Sentinel 4 focal plane subsystem

    Science.gov (United States)

    Hohn, Rüdiger; Skegg, Michael P.; Hermsen, Markus; Hinger, Jürgen; Williges, Christian; Reulke, Ralf

    2017-09-01

    The Sentinel 4 instrument is an imaging spectrometer, developed by Airbus under ESA contract in the frame of the joint European Union (EU)/ESA COPERNICUS program with the objective of monitoring trace gas concentrations. Sentinel 4 will provide accurate measurements of key atmospheric constituents such as ozone, nitrogen dioxide, sulfur dioxide, formaldehyde, as well as aerosol and cloud properties. Sentinel 4 is unique in being the first geostationary UVN mission. The SENTINEL 4 space segment will be integrated on EUMETSAT's Meteosat Third Generation Sounder satellite (MTG-S). Sentinel 4 will provide coverage of Europe and adjacent regions. The Sentinel 4 instrument comprises as a major element two Focal Plane Subsystems (FPS) covering the wavelength ranges 305 nm to 500 nm (UVVIS) and 750 nm to 775 nm (NIR) respectively. The paper describes the Focal Plane Subsystems, comprising the detectors, the optical bench and the control electronics. Further the design and development approach will be presented as well as first measurement results of FPS Qualification Model.

  8. Focal Colonic FDG Activity with PET/CT: Guidelines for Recommendation of Colonoscopy

    International Nuclear Information System (INIS)

    Liu, Tianye; Behr, Spencer; Khan, Sana; Osterhoff, Robert; Aparici, Carina Mari

    2015-01-01

    Focal 18 F-fluorodeoxyglucose (FDG) colonic activity can be incidentally seen in positron emission tomography/computed tomography (PET/CT) scans. Its clinical significance is still unclear. The purpose of this study was to assess the significance of focal FDG activity in PET/CT scans by correlating the imaging findings to colonoscopy results, and come up with some guidelines for recommendation of follow-up colonoscopy. A total of 133 patients who underwent both 18 F-FDG PET/CT for different oncological indications and colonoscopy within 3 months were retrospectively studied. Imaging, colonoscopy and pathology results were analyzed. Of the 133 FDG-PET/CT scans, 109/133 (82%) did not show focal colonic FDG activity, and 24/133 (18%) did. Of the 109/133 PET/CTs without focal colonic FDG activity, 109/109 (100%) did not have evidence of colon cancer after colonoscopy and histology. Of the 24/133 PET/CTs with focal colonic FDG activity, 10/24 (42%) had pathologic confirmation of colon cancer and 14/24 (58%) did not have evidence of colon cancer after colonoscopy and histological analysis. Sensitivity was 10/10 (100%), specificity 109/123 (89%), positive predictive value (PPV) 10/24 (42%) and negative predictive value (NPV) 109/109 (100%). Incidental focal 18 FDG activity in PET/CT imaging shows a high sensitivity, specificity and NPV for malignancy, with a not so high PPV of 42%. Although some people would argue that a 42% chance of malignancy justifies colonoscopy, this maybe is not possible in all cases. However, the high sensitivity of the test does not allow these studies to be overlooked. We provide our recommendations as per when to send patients with focal FDG colonic activity to have further characterization with colonoscopy

  9. Efficiency of subsoiling depth according to the slope of the land

    Directory of Open Access Journals (Sweden)

    Daniel Pena Pereira

    2012-12-01

    Full Text Available The effectiveness of subsoiling by measuring the depths achieved in different classes of slope of a forest plantation was evaluated. This operation was made with a fertilizer trawling subsoiler with a single smooth parabolic rod depending on seven groups of slope and the maximum lateral inclination of the tractor to perform the subsoiling. It was determined the number and breadth of slope classes by Sturges formula. Data were assessed by regression analysis for data with repetition at 5% significance level. The proposed regression model was adequate to describe the values given that it presented significant result for the F test. For the adjustment of the regression equation, the coefficient of determination was 78.95%, representing the the depth values that are explained by the slope. Thus, it can be said that the depth of subsoiling decreases as the steepness of the ground increases and is a limiter for the quality of the mechanized soil preparation. The results demonstrate that slopes up to 40% allowed the operation of subsoiling to reach the minimum depth of 0.50 m for forest cultivation.

  10. Improved detection of focal pneumonia by chest radiography with bone suppression imaging

    International Nuclear Information System (INIS)

    Li, Feng; Engelmann, Roger; Pesce, Lorenzo; Armato, Samuel G.; MacMahon, Heber

    2012-01-01

    To evaluate radiologists' ability to detect focal pneumonia by use of standard chest radiographs alone compared with standard plus bone-suppressed chest radiographs. Standard chest radiographs in 36 patients with 46 focal airspace opacities due to pneumonia (10 patients had bilateral opacities) and 20 patients without focal opacities were included in an observer study. A bone suppression image processing system was applied to the 56 radiographs to create corresponding bone suppression images. In the observer study, eight observers, including six attending radiologists and two radiology residents, indicated their confidence level regarding the presence of a focal opacity compatible with pneumonia for each lung, first by use of standard images, then with the addition of bone suppression images. Receiver operating characteristic (ROC) analysis was used to evaluate the observers' performance. The mean value of the area under the ROC curve (AUC) for eight observers was significantly improved from 0.844 with use of standard images alone to 0.880 with standard plus bone suppression images (P < 0.001) based on 46 positive lungs and 66 negative lungs. Use of bone suppression images improved radiologists' performance for detection of focal pneumonia on chest radiographs. (orig.)

  11. Improved detection of focal pneumonia by chest radiography with bone suppression imaging

    Energy Technology Data Exchange (ETDEWEB)

    Li, Feng; Engelmann, Roger; Pesce, Lorenzo; Armato, Samuel G.; MacMahon, Heber [University of Chicago, Department of Radiology, MC-2026, Chicago, IL (United States)

    2012-12-15

    To evaluate radiologists' ability to detect focal pneumonia by use of standard chest radiographs alone compared with standard plus bone-suppressed chest radiographs. Standard chest radiographs in 36 patients with 46 focal airspace opacities due to pneumonia (10 patients had bilateral opacities) and 20 patients without focal opacities were included in an observer study. A bone suppression image processing system was applied to the 56 radiographs to create corresponding bone suppression images. In the observer study, eight observers, including six attending radiologists and two radiology residents, indicated their confidence level regarding the presence of a focal opacity compatible with pneumonia for each lung, first by use of standard images, then with the addition of bone suppression images. Receiver operating characteristic (ROC) analysis was used to evaluate the observers' performance. The mean value of the area under the ROC curve (AUC) for eight observers was significantly improved from 0.844 with use of standard images alone to 0.880 with standard plus bone suppression images (P < 0.001) based on 46 positive lungs and 66 negative lungs. Use of bone suppression images improved radiologists' performance for detection of focal pneumonia on chest radiographs. (orig.)

  12. Nodular focal fatty infiltration of the liver: CT appearance

    International Nuclear Information System (INIS)

    Baker, M.E.; Silverman, P.M.

    1985-01-01

    Focal fatty infiltration of the liver is a well recognized entity generally characterized by a nonspherical, low-density area without significant mass effect. CT usually distinguishes this from focal liver processes such as abscess or metastasis by its sharply marginated, geographic pattern and lack of mass effect on hepatic and portal veins. Recently, the authors formed a CT scan of the liver in one patient in whom fatty infiltration appeared nodular or rounded. The clinical presentation and radiographic and pathologic features form the basis of this report

  13. The radiological features of Goltz syndrome: Focal dermal hypoplasia

    International Nuclear Information System (INIS)

    Boothyrod, A.E.; Hall, C.M.

    1988-01-01

    Two female infants with Goltz syndrome (focal dermal hypoplasia) were recently investigated for severe feeding problems and failure to thrive. Both demonstrated severe skeletal malformations and marked gastrooesophageal reflux with laxity of the hiatus. One child (case 1) exhibited nasal regurgitation during feeding. Interestingly, both children had undergone surgery; Case 1 or a right parasagittal abdominal hernia associated with focal dermal hypoplasia of the abdominal wall and Case 2 for an exomphalos also associated with dermal hypoplasia. This observation suggests more widespread mesodermal abnormality. (orig./GDG)

  14. Idiopathic focal epilepsies: the "lost tribe".

    Science.gov (United States)

    Pal, Deb K; Ferrie, Colin; Addis, Laura; Akiyama, Tomoyuki; Capovilla, Giuseppe; Caraballo, Roberto; de Saint-Martin, Anne; Fejerman, Natalio; Guerrini, Renzo; Hamandi, Khalid; Helbig, Ingo; Ioannides, Andreas A; Kobayashi, Katsuhiro; Lal, Dennis; Lesca, Gaetan; Muhle, Hiltrud; Neubauer, Bernd A; Pisano, Tiziana; Rudolf, Gabrielle; Seegmuller, Caroline; Shibata, Takashi; Smith, Anna; Striano, Pasquale; Strug, Lisa J; Szepetowski, Pierre; Valeta, Thalia; Yoshinaga, Harumi; Koutroumanidis, Michalis

    2016-09-01

    The term idiopathic focal epilepsies of childhood (IFE) is not formally recognised by the ILAE in its 2010 revision (Berg et al., 2010), nor are its members and boundaries precisely delineated. The IFEs are amongst the most commonly encountered epilepsy syndromes affecting children. They are fascinating disorders that hold many "treats" for both clinicians and researchers. For example, the IFEs pose many of the most interesting questions central to epileptology: how are functional brain networks involved in the manifestation of epilepsy? What are the shared mechanisms of comorbidity between epilepsy and neurodevelopmental disorders? How do focal EEG discharges impact cognitive functioning? What explains the age-related expression of these syndromes? Why are EEG discharges and seizures so tightly locked to slow-wave sleep? In the last few decades, the clinical symptomatology and the respective courses of many IFEs have been described, although they are still not widely appreciated beyond the specialist community. Most neurologists would recognise the core syndromes of IFE to comprise: benign epilepsy of childhood with centro-temporal spikes or Rolandic epilepsy (BECTS/RE); Panayiotopoulos syndrome; and the idiopathic occipital epilepsies (Gastaut and photosensitive types). The Landau-Kleffner syndrome and the related (idiopathic) epilepsy with continuous spikes and waves in sleep (CSWS or ESES) are also often included, both as a consequence of the shared morphology of the interictal discharges and their potential evolution from core syndromes, for example, CSWS from BECTS. Atypical benign focal epilepsy of childhood also has shared electro-clinical features warranting inclusion. In addition, a number of less well-defined syndromes of IFE have been proposed, including benign childhood seizures with affective symptoms, benign childhood epilepsy with parietal spikes, benign childhood seizures with frontal or midline spikes, and benign focal seizures of adolescence. The

  15. Enhanced nutrient transport improves the depth-dependent properties of tri-layered engineered cartilage constructs with zonal co-culture of chondrocytes and MSCs.

    Science.gov (United States)

    Kim, Minwook; Farrell, Megan J; Steinberg, David R; Burdick, Jason A; Mauck, Robert L

    2017-08-01

    Biomimetic design in cartilage tissue engineering is a challenge given the complexity of the native tissue. While numerous studies have generated constructs with near-native bulk properties, recapitulating the depth-dependent features of native tissue remains a challenge. Furthermore, limitations in nutrient transport and matrix accumulation in engineered constructs hinders maturation within the central core of large constructs. To overcome these limitations, we fabricated tri-layered constructs that recapitulate the depth-dependent cellular organization and functional properties of native tissue using zonally derived chondrocytes co-cultured with MSCs. We also introduced porous hollow fibers (HFs) and HFs/cotton threads to enhance nutrient transport. Our results showed that tri-layered constructs with depth-dependent organization and properties could be fabricated. The addition of HFs or HFs/threads improved matrix accumulation in the central core region. With HF/threads, the local modulus in the deep region of tri-layered constructs nearly matched that of native tissue, though the properties in the central regions remained lower. These constructs reproduced the zonal organization and depth-dependent properties of native tissue, and demonstrate that a layer-by-layer fabrication scheme holds promise for the biomimetic repair of focal cartilage defects. Articular cartilage is a highly organized tissue driven by zonal heterogeneity of cells, extracellular matrix proteins and fibril orientations, resulting in depth-dependent mechanical properties. Therefore, the recapitulation of the functional properties of native cartilage in a tissue engineered construct requires such a biomimetic design of the morphological organization, and this has remained a challenge in cartilage tissue engineering. This study demonstrates that a layer-by-layer fabrication scheme, including co-cultures of zone-specific articular CHs and MSCs, can reproduce the depth-dependent characteristics

  16. Knee Kinetics during Squats of Varying Loads and Depths in Recreationally Trained Females.

    Science.gov (United States)

    Flores, Victoria; Becker, James; Burkhardt, Eric; Cotter, Joshua

    2018-03-06

    The back squat exercise is typically practiced with varying squat depths and barbell loads. However, depth has been inconsistently defined, resulting in unclear safety precautions when squatting with loads. Additionally, females exhibit anatomical and kinematic differences to males which may predispose them to knee joint injuries. The purpose of this study was to characterize peak knee extensor moments (pKEMs) at three commonly practiced squat depths of above parallel, parallel, and full depth, and with three loads of 0% (unloaded), 50%, and 85% depth-specific one repetition maximum (1RM) in recreationally active females. Nineteen females (age, 25.1 ± 5.8 years; body mass, 62.5 ± 10.2 kg; height, 1.6 ± 0.10 m; mean ± SD) performed squats of randomized depth and load. Inverse dynamics were used to obtain pKEMs from three-dimensional knee kinematics. Depth and load had significant interaction effects on pKEMs (p = 0.014). Significantly greater pKEMs were observed at full depth compared to parallel depth with 50% 1RM load (p = 0.001, d = 0.615), and 85% 1RM load (p = 0.010, d = 0.714). Greater pKEMs were also observed at full depth compared to above parallel depth with 50% 1RM load (p = 0.003, d = 0.504). Results indicate effect of load on female pKEMs do not follow a progressively increasing pattern with either increasing depth or load. Therefore, when high knee loading is a concern, individuals are must carefully consider both the depth of squat being performed and the relative load they are using.

  17. Aspectos clínicos y electroencefalográficos de la epilepsia focal en el niño Clinical and electroencephalographic features of focal epilepsy present in children

    Directory of Open Access Journals (Sweden)

    Albia Pozo Alonso

    2009-06-01

    Full Text Available INTRODUCCIÓN. El objetivo del presente trabajo fue caracterizar un grupo de pacientes con epilepsias focales, según aspectos clínicos y electroencefalográficos. MÉTODOS. Se realizó un estudio descriptivo y prospectivo de 185 niños con diagnóstico de epilepsia focal (2 o más crisis epilépticas no provocadas, con edades entre un mes y 14 años, que fueron hospitalizados en el Departamento de Neuropediatría del Hospital «William Soler» entre diciembre de 2001 y diciembre de 2003. RESULTADOS. La edad media de inicio de la primera crisis epiléptica fue de 5 años. El tipo de crisis epiléptica focal más frecuente fue la simple (49,2 %. El 48,6 % de los niños presentó etiología idiopática y el 33,0 % sintomática. Los factores de la etiología sintomática más frecuentes fueron los prenatales (56,2 %. El 91,4 % de los pacientes presentó electroencefalogramas iniciales interictales anormales. El electroencefalograma focal se observó en el 37,3 % de los niños y el multifocal en el 24,9 %. El síndrome epiléptico más frecuente fue la epilepsia benigna con puntas centrotemporales (5,9 %. CONCLUSIONES. Los niños con epilepsia focal tienen variadas manifestaciones clínicas y electroencefalográficas, y en la mayoría de los pacientes no es posible identificar un síndrome epiléptico.INTRODUCTION: The aim of present paper was to characterize a group of patients presenting with focal epilepsies by clinical and electroencephalographic features. METHODS: Authors made a descriptive and cross-sectional study in 185 children diagnosed with focal epilepsy (two or more non-provoked epilepsy crises, aged from one month to 14, admitted in Neurology Department of "William Soler" Children Hospital between December 2001 to December 2003. RESULTS: Mean age of the first epilepsy crisis was at 5 years. The more frequent type of focal epilepsy crisis was the simple one (49, 2%. The 48, 6% of children presented with a idiopathic origin, and the 33

  18. Dual focal-spot imaging for phase extraction in phase-contrast radiography

    International Nuclear Information System (INIS)

    Donnelly, Edwin F.; Price, Ronald R.; Pickens, David R.

    2003-01-01

    The purpose of this study was to evaluate dual focal spot imaging as a method for extracting the phase component from a phase-contrast radiography image. All measurements were performed using a microfocus tungsten-target x-ray tube with an adjustable focal-spot size (0.01 mm to 0.045 mm). For each object, high-resolution digital radiographs were obtained with two different focal spot sizes to produce matched image pairs in which all other geometric variables as well as total exposure and tube kVp were held constant. For each image pair, a phase extraction was performed using pixel-wise division. The phase-extracted image resulted in an image similar to the standard image processing tool commonly referred to as 'unsharp masking' but with the additional edge-enhancement produced by phase-contrast effects. The phase-extracted image illustrates the differences between the two images whose imaging parameters differ only in focal spot size. The resulting image shows effects from both phase contrast as well as geometric unsharpness. In weakly attenuating materials the phase-contrast effect predominates, while in strongly attenuating materials the phase effects are so small that they are not detectable. The phase-extracted image in the strongly attenuating object reflects differences in geometric unsharpness. The degree of phase extraction depends strongly on the size of the smallest focal spot used. This technique of dual-focal spot phase-contrast radiography provides a simple technique for phase-component (edge) extraction in phase-contrast radiography. In strongly attenuating materials the phase-component is overwhelmed by differences in geometric unsharpness. In these cases the technique provides a form of unsharp masking which also accentuates the edges. Thus, the two effects are complimentary and may be useful in the detection of small objects

  19. Imaging the 2017 MW 8.2 Tehuantepec intermediate-depth earthquake using Teleseismic P Waves

    Science.gov (United States)

    Brudzinski, M.; Zhang, H.; Koper, K. D.; Pankow, K. L.

    2017-12-01

    The September 8, 2017 MW 8.1 Tehuantepec, Mexico earthquakes in the middle American subduction zone is one of the largest intermediate-depth earthquake ever recorded and could provide an unprecedented opportunity for understanding the mechanism of intermediate-depth earthquakes. While the hypocenter and centroid depths for this earthquake are shallower than typically considered for intermediate depth earthquakes, the normal faulting mechanism consistent with down-dip extension and location within the subducting plate align with properties of intermediate depth earthquakes. Back-projection of high-frequency teleseismic P-waves from two regional arrays for this earthquake shows unilateral rupture on a southeast-northwest striking fault that extends north of the Tehuantepec fracture zone (TFZ), with an average horizontal rupture speed of 3.0 km/s and total duration of 60 s. Guided by these back-projection results, 47 globally distributed low-frequency P-waves were inverted for a finite-fault model (FFM) of slip for both nodal planes. The FFM shows a slip deficit in proximity to the extension of the TFZ, as well as the minor rupture beyond the TFZ (confirmed by the synthetic tests), which indicates that the TFZ acted as a barrier for this earthquake. Analysis of waveform misfit leads to the preference of a subvertical plane as the causative fault. The FFM shows that the majority of the rupture is above the focal depth and consists of two large slip patches: the first one is near the hypocenter ( 55 km depth) and the second larger one near 30 km depth. The distribution of the two patches spatially agrees with seismicity that defines the upper and lower zones of a double Benioff zone (DBZ). It appears there was single fault rupture across the two depth zones of the DBZ. This is uncommon because a stark aseismic zone is typically observed between the upper and lower zones of the DBZ. This finding indicates that the mechanism for intraslab earthquakes must allow for

  20. Mutations in KCNT1 cause a spectrum of focal epilepsies

    Science.gov (United States)

    Møller, Rikke S.; Heron, Sarah E.; Larsen, Line H. G.; Lim, Chiao Xin; Ricos, Michael G.; Bayly, Marta A.; van Kempen, Marjan J. A.; Klinkenberg, Sylvia; Andrews, Ian; Kelley, Kent; Ronen, Gabriel M.; Callen, David; McMahon, Jacinta M.; Yendle, Simone C.; Carvill, Gemma L.; Mefford, Heather C.; Nabbout, Rima; Poduri, Annapurna; Striano, Pasquale; Baglietto, Maria G.; Zara, Federico; Smith, Nicholas J.; Pridmore, Clair; Gardella, Elena; Nikanorova, Marina; Dahl, Hans Atli; Gellert, Pia; Scheffer, Ingrid E.; Gunning, Boudewijn; Kragh-Olsen, Bente; Dibbens, Leanne M.

    2018-01-01

    Summary Autosomal dominant mutations in the sodium-gated potassium channel subunit gene KCNT1 have been associated with two distinct seizure syndromes, nocturnal frontal lobe epilepsy (NFLE) and malignant migrating focal seizures of infancy (MMFSI). To further explore the phenotypic spectrum associated with KCNT1, we examined individuals affected with focal epilepsy or an epileptic encephalopathy for mutations in the gene. We identified KCNT1 mutations in 12 previously unreported patients with focal epilepsy, multifocal epilepsy, cardiac arrhythmia, and in a family with sudden unexpected death in epilepsy (SUDEP), in addition to patients with NFLE and MMFSI. In contrast to the 100% penetrance so far reported for KCNT1 mutations, we observed incomplete penetrance. It is notable that we report that the one KCNT1 mutation, p.Arg398Gln, can lead to either of the two distinct phenotypes, ADNFLE or MMFSI, even within the same family. This indicates that genotype–phenotype relationships for KCNT1 mutations are not straightforward. We demonstrate that KCNT1 mutations are highly pleiotropic and are associated with phenotypes other than ADNFLE and MMFSI. KCNT1 mutations are now associated with Ohtahara syndrome, MMFSI, and nocturnal focal epilepsy. They may also be associated with multifocal epilepsy and cardiac disturbances. PMID:26122718

  1. Focal Therapy: Patients, Interventions, and Outcomes—A Report from a Consensus Meeting

    Science.gov (United States)

    Donaldson, Ian A.; Alonzi, Roberto; Barratt, Dean; Barret, Eric; Berge, Viktor; Bott, Simon; Bottomley, David; Eggener, Scott; Ehdaie, Behfar; Emberton, Mark; Hindley, Richard; Leslie, Tom; Miners, Alec; McCartan, Neil; Moore, Caroline M.; Pinto, Peter; Polascik, Thomas J.; Simmons, Lucy; van der Meulen, Jan; Villers, Arnauld; Willis, Sarah; Ahmed, Hashim U.

    2015-01-01

    Background Focal therapy as a treatment option for localized prostate cancer (PCa) is an increasingly popular and rapidly evolving field. Objective To gather expert opinion on patient selection, interventions, and meaningful outcome measures for focal therapy in clinical practice and trial design. Design, setting, and participants Fifteen experts in focal therapy followed a modified two-stage RAND/University of California, Los Angeles (UCLA) Appropriateness Methodology process. All participants independently scored 246 statements prior to rescoring at a face-to-face meeting. The meeting occurred in June 2013 at the Royal Society of Medicine, London, supported by the Wellcome Trust and the UK Department of Health. Outcome measurements and statistical analysis Agreement, disagreement, or uncertainty were calculated as the median panel score. Consensus was derived from the interpercentile range adjusted for symmetry level. Results and limitations Of 246 statements, 154 (63%) reached consensus. Items of agreement included the following: patients with intermediate risk and patients with unifocal and multifocal PCa are eligible for focal treatment; magnetic resonance imaging–targeted or template-mapping biopsy should be used to plan treatment; planned treatment margins should be 5 mm from the known tumor; prostate volume or age should not be a primary determinant of eligibility; foci of indolent cancer can be left untreated when treating the dominant index lesion; histologic outcomes should be defined by targeted biopsy at 1 yr; residual disease in the treated area of ≤3 mm of Gleason 3 + 3 did not need further treatment; and focal retreatment rates of ≤20% should be considered clinically acceptable but subsequent whole-gland therapy deemed a failure of focal therapy. All statements are expert opinion and therefore constitute level 5 evidence and may not reflect wider clinical consensus. Conclusions The landscape of PCa treatment is rapidly evolving with new

  2. Inferences about the local stress field from focal mechanisms: Applications to earthquakes in the southern Great Basin of Nevada

    International Nuclear Information System (INIS)

    Harmsen, S.C.; Rogers, A.M.

    1986-01-01

    Focal mechanisms determined from regional-network earthquake data or aftershock field investigation often contain members ranging from strike slip to normal slip in extensional tectonic environments or from strike slip to thrust slip in compressional environments. Although the coexistence of normal and strike-slip faulting has suggested to some investigators that the maximum and intermediate principal stresses are of approximately equal magnitude, several have asserted that the directions of principle stresses can or must interchange to accommodate both types of mechanisms (Zoback and Zoback 1980b; Vetter and Ryall, 1983). A Coulomb-Navier criterion of slip is invoked to demonstrate that both types of mechanisms, as well as oblique members having preferred nodal-plane dips intermediate between those of the strike-slip and normal mechanisms, may be observed in a region where the stress field, resolved into principal components, is axially symmetric. The proximate coexistence of earthquakes having diverse focal mechanisms could be interpreted as evidence for an approximately axially symmetric stress field in a region where optimally oriented planes of weakness are known to exist in the host rock. 10 refs., 6 figs

  3. US and CT findings in splenic focal lesions in AIDS

    International Nuclear Information System (INIS)

    Schinina, V.; Rizzi, E.B.; Mazzuoli, G.; Bibbolilno, C.; David, V.

    2000-01-01

    To evaluate the role of US and CT in focal splenic lesions in AIDS patients in relation to etiology. Material and Methods: A total of 66 patients with AIDS and focal splenic lesions were examined with sonography. CT with administration of contrast medium was performed in 12 cases. Results: Of the focal splenic lesions, 67% were correlated with an infective pathology with prevalence of Mycobacteria tuberculosis (75%), 26% were neoplastic and 6% splenic infarcts. The lesions were hypoechoic in 60% of the cases, while 10% were hypoanechoic and 1% anechoic. At CT, all lesions appeared hypodense, even after i.v. administration of contrast medium. Conclusion: The combination of echographic reports and clinical and laboratory data allows for a diagnosis that can be confirmed, and making a decision for effective therapy of AIDS is possible. CT does not provide any additional information

  4. Comparison in performance of sediment microbial fuel cells according to depth of embedded anode.

    Science.gov (United States)

    An, Junyeong; Kim, Bongkyu; Nam, Jonghyeon; Ng, How Yong; Chang, In Seop

    2013-01-01

    Five rigid graphite plates were embedded in evenly divided sections of sediment, ranging from 2 cm (A1) to 10 cm (A5) below the top sediment layer. The maximum power and current of the MFCs increased in depth order; however, despite the increase in the internal resistance, the power and current density of the A5 MFC were 2.2 and 3.5 times higher, respectively, than those of the A1 MFC. In addition, the anode open circuit potentials (OCPs) of the sediment microbial fuel cells (SMFCs) became more negative with sediment depth. Based on these results, it could be then concluded that as the anode-embedding depth increases, that the anode environment is thermodynamically and kinetically favorable to anodophiles or electrophiles. Therefore, the anode-embedding depth should be considered an important parameter that determines the performance of SMFCs, and we posit that the anode potential could be one indicator for selecting the anode-embedding depth. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. MRI in assessing children with learning disability, focal findings, and reduced automaticity.

    Science.gov (United States)

    Urion, David K; Huff, Hanalise V; Carullo, Maria Paulina

    2015-08-18

    In children with clinically diagnosed learning disabilities with focal findings on neurologic or neuropsychological evaluations, there is a hypothesized association between disorders in automaticity and focal structural abnormalities observed in brain MRIs. We undertook a retrospective analysis of cases referred to a tertiary-hospital-based learning disabilities program. Individuals were coded as having a focal deficit if either neurologic or neuropsychological evaluation demonstrated focal dysfunction. Those with abnormal MRI findings were categorized based on findings. Children with abnormalities from each of these categories were compared in terms of deficits in automaticity, as measured by the tasks of Rapid Automatized Naming, Rapid Alternating Stimulus Naming, or the timed motor performance battery from the Physical and Neurological Examination for Soft Signs. Data were compared in children with and without disorders of automaticity regarding type of brain structure abnormality. Of the 1,587 children evaluated, 127 had a focal deficit. Eighty-seven had a brain MRI (52 on 1.5-tesla machines and 35 on 3.0-tesla machines). Forty of these images were found to be abnormal. These children were compared with a clinic sample of 150 patients with learning disabilities and no focal findings on examination, who also had undergone MRI. Only 5 of the latter group had abnormalities on MRI. Reduced verbal automaticity was associated with cerebellar abnormalities, whereas reduced automaticity on motor or motor and verbal tasks was associated with white matter abnormalities. Reduced automaticity of retrieval and slow timed motor performance appear to be highly associated with MRI findings. © 2015 American Academy of Neurology.

  6. X-ray tube focal spot sizes: comprehensive studies of their measurement and effect of measured size in angiography

    International Nuclear Information System (INIS)

    Doi, K.; Loo, L.N.; Chan, H.P.

    1982-01-01

    Thirty-two focal spot sizes of four x-ray tubes were measured by the pinhole, star pattern, slit, and root-mean-square (RMS) methods under various exposure conditions. The modulation transfer functions (MTFs) and line spread functions (LSFs) were also determined. The star pattern focal spot sizes agreed with the effective sizes calculated from the frequencies at the first minimum of the MTF within 0.04 mm for large focal spots and within 0.01 mm for small focal spots. The focal spot size determined by the slit method was approximately equal to the width of the LSF at the cutoff level of 0.15 +/- 0.06 of the peak value. The RMS method provided the best correlation between the measured focal spot sizes and the corresponding image distributions of blood vessels. The pinhole and slit methods tended to overestimate the focal spot size, but the star pattern method tended to underestimate it. For approximately 90% of the focal spots, the average of the star and slit (or pinhole) focal spot sizes agreed with the RMS focal spot size within +/- 0.1 mm

  7. Focal plane scanner with reciprocating spatial window

    Science.gov (United States)

    Mao, Chengye (Inventor)

    2000-01-01

    A focal plane scanner having a front objective lens, a spatial window for selectively passing a portion of the image therethrough, and a CCD array for receiving the passed portion of the image. All embodiments have a common feature whereby the spatial window and CCD array are mounted for simultaneous relative reciprocating movement with respect to the front objective lens, and the spatial window is mounted within the focal plane of the front objective. In a first embodiment, the spatial window is a slit and the CCD array is one-dimensional, and successive rows of the image in the focal plane of the front objective lens are passed to the CCD array by an image relay lens interposed between the slit and the CCD array. In a second embodiment, the spatial window is a slit, the CCD array is two-dimensional, and a prism-grating-prism optical spectrometer is interposed between the slit and the CCD array so as to cause the scanned row to be split into a plurality of spectral separations onto the CCD array. In a third embodiment, the CCD array is two-dimensional and the spatial window is a rectangular linear variable filter (LVF) window, so as to cause the scanned rows impinging on the LVF to be bandpass filtered into spectral components onto the CCD array through an image relay lens interposed between the LVF and the CCD array.

  8. The depth distribution of bubbles and fracture in He+ and D+ irradiated copper

    International Nuclear Information System (INIS)

    Johnson, P.B.; Mazey, D.J.

    1982-01-01

    Transmission electron microscopy is used to investigate the spatial arrangement and distribution with depth of gas bubbles produced in Cu by irradiation at 320 K to a level approx. equal to 4 x 10 21 30 keV He + m -2 . At the depth of maximum bubble size the bubbles are random and large (up to approx. equal to 10 nm across). At both shallower and greater depths the gas bubbles are smaller (approx. equal to 2 nm diam), much more uniform in size and ordered on an fcc superlattice with a lattice constant of a 1 approx. equal to 7.7 nm which (in contrast to the average bubble size) is independent of depth. It is suggested that blistering results from fracture, at a depth near the mean projected range, between large randomly-ordered bubbles which have evolved from smaller bubbles of uniform size arranged on a superlattice. For the particular case of D + irradiation of Cu at 120 K evidence is found to suggest that the fracture mechanisms involved in blistering and flaking are quite different. (orig.)

  9. Evaluation of focused ultrasound algorithms: Issues for reducing pre-focal heating and treatment time.

    Science.gov (United States)

    Yiannakou, Marinos; Trimikliniotis, Michael; Yiallouras, Christos; Damianou, Christakis

    2016-02-01

    Due to the heating in the pre-focal field the delay between successive movements in high intensity focused ultrasound (HIFU) are sometimes as long as 60s, resulting to treatment time in the order of 2-3h. Because there is generally a requirement to reduce treatment time, we were motivated to explore alternative transducer motion algorithms in order to reduce pre-focal heating and treatment time. A 1 MHz single element transducer with 4 cm diameter and 10 cm focal length was used. A simulation model was developed that estimates the temperature, thermal dose and lesion development in the pre-focal field. The simulated temperature history that was combined with the motion algorithms produced thermal maps in the pre-focal region. Polyacrylimde gel phantom was used to evaluate the induced pre-focal heating for each motion algorithm used, and also was used to assess the accuracy of the simulation model. Three out of the six algorithms having successive steps close to each other, exhibited severe heating in the pre-focal field. Minimal heating was produced with the algorithms having successive steps apart from each other (square, square spiral and random). The last three algorithms were improved further (with small cost in time), thus eliminating completely the pre-focal heating and reducing substantially the treatment time as compared to traditional algorithms. Out of the six algorithms, 3 were successful in eliminating the pre-focal heating completely. Because these 3 algorithms required no delay between successive movements (except in the last part of the motion), the treatment time was reduced by 93%. Therefore, it will be possible in the future, to achieve treatment time of focused ultrasound therapies shorter than 30 min. The rate of ablated volume achieved with one of the proposed algorithms was 71 cm(3)/h. The intention of this pilot study was to demonstrate that the navigation algorithms play the most important role in reducing pre-focal heating. By evaluating in

  10. Statistically sound evaluation of trace element depth profiles by ion beam analysis

    International Nuclear Information System (INIS)

    Schmid, K.; Toussaint, U. von

    2012-01-01

    This paper presents the underlying physics and statistical models that are used in the newly developed program NRADC for fully automated deconvolution of trace level impurity depth profiles from ion beam data. The program applies Bayesian statistics to find the most probable depth profile given ion beam data measured at different energies and angles for a single sample. Limiting the analysis to % level amounts of material allows one to linearize the forward calculation of ion beam data which greatly improves the computation speed. This allows for the first time to apply the maximum likelihood approach to both the fitting of the experimental data and the determination of confidence intervals of the depth profiles for real world applications. The different steps during the automated deconvolution will be exemplified by applying the program to artificial and real experimental data.

  11. ADAMTS9-Regulated Pericellular Matrix Dynamics Governs Focal Adhesion-Dependent Smooth Muscle Differentiation

    Directory of Open Access Journals (Sweden)

    Timothy J. Mead

    2018-04-01

    Full Text Available Summary: Focal adhesions anchor cells to extracellular matrix (ECM and direct assembly of a pre-stressed actin cytoskeleton. They act as a cellular sensor and regulator, linking ECM to the nucleus. Here, we identify proteolytic turnover of the anti-adhesive proteoglycan versican as a requirement for maintenance of smooth muscle cell (SMC focal adhesions. Using conditional deletion in mice, we show that ADAMTS9, a secreted metalloprotease, is required for myometrial activation during late gestation and for parturition. Through knockdown of ADAMTS9 in uterine SMC, and manipulation of pericellular versican via knockdown or proteolysis, we demonstrate that regulated pericellular matrix dynamics is essential for focal adhesion maintenance. By influencing focal adhesion formation, pericellular versican acts upstream of cytoskeletal assembly and SMC differentiation. Thus, pericellular versican proteolysis by ADAMTS9 balances pro- and anti-adhesive forces to maintain an SMC phenotype, providing a concrete example of the dynamic reciprocity of cells and their ECM. : Mead et al. identify a proteolytic mechanism that actively maintains a pericellular microenvironment conducive to uterine smooth muscle activation prior to parturition. They show that pericellular matrix proteolysis by the secreted metalloprotease ADAMTS9 is crucial for maintenance of focal adhesions in uterine smooth muscle cells, and its absence impairs parturition. Keywords: metalloprotease, extracellular matrix, smooth muscle, proteoglycan, myometrium, parturition, uterus, focal adhesion, proteolysis, interference reflection microscopy

  12. Maximum likelihood estimation of the position of a radiating source in a waveguide

    International Nuclear Information System (INIS)

    Hinich, M.J.

    1979-01-01

    An array of sensors is receiving radiation from a source of interest. The source and the array are in a one- or two-dimensional waveguide. The maximum-likelihood estimators of the coordinates of the source are analyzed under the assumptions that the noise field is Gaussian. The Cramer-Rao lower bound is of the order of the number of modes which define the source excitation function. The results show that the accuracy of the maximum likelihood estimator of source depth using a vertical array in a infinite horizontal waveguide (such as the ocean) is limited by the number of modes detected by the array regardless of the array size

  13. Integration time for the perception of depth from motion parallax.

    Science.gov (United States)

    Nawrot, Mark; Stroyan, Keith

    2012-04-15

    The perception of depth from relative motion is believed to be a slow process that "builds-up" over a period of observation. However, in the case of motion parallax, the potential accuracy of the depth estimate suffers as the observer translates during the viewing period. Our recent quantitative model for the perception of depth from motion parallax proposes that relative object depth (d) can be determined from retinal image motion (dθ/dt), pursuit eye movement (dα/dt), and fixation distance (f) by the formula: d/f≈dθ/dα. Given the model's dynamics, it is important to know the integration time required by the visual system to recover dα and dθ, and then estimate d. Knowing the minimum integration time reveals the incumbent error in this process. A depth-phase discrimination task was used to determine the time necessary to perceive depth-sign from motion parallax. Observers remained stationary and viewed a briefly translating random-dot motion parallax stimulus. Stimulus duration varied between trials. Fixation on the translating stimulus was monitored and enforced with an eye-tracker. The study found that relative depth discrimination can be performed with presentations as brief as 16.6 ms, with only two stimulus frames providing both retinal image motion and the stimulus window motion for pursuit (mean range=16.6-33.2 ms). This was found for conditions in which, prior to stimulus presentation, the eye was engaged in ongoing pursuit or the eye was stationary. A large high-contrast masking stimulus disrupted depth-discrimination for stimulus presentations less than 70-75 ms in both pursuit and stationary conditions. This interval might be linked to ocular-following response eye-movement latencies. We conclude that neural mechanisms serving depth from motion parallax generate a depth estimate much more quickly than previously believed. We propose that additional sluggishness might be due to the visual system's attempt to determine the maximum dθ/dα ratio

  14. The Power of Poincar\\'e: Elucidating the Hidden Symmetries in Focal Conic Domains

    OpenAIRE

    Alexander, Gareth P.; Chen, Bryan Gin-ge; Matsumoto, Elisabetta A.; Kamien, Randall D.

    2010-01-01

    Focal conic domains are typically the "smoking gun" by which smectic liquid crystalline phases are identified. The geometry of the equally-spaced smectic layers is highly generic but, at the same time, difficult to work with. In this Letter we develop an approach to the study of focal sets in smectics which exploits a hidden Poincar\\'e symmetry revealed only by viewing the smectic layers as projections from one-higher dimension. We use this perspective to shed light upon several classic focal...

  15. A Micro-Thermal Sensor for Focal Therapy Applications

    Science.gov (United States)

    Natesan, Harishankar; Hodges, Wyatt; Choi, Jeunghwan; Lubner, Sean; Dames, Chris; Bischof, John

    2016-02-01

    There is an urgent need for sensors deployed during focal therapies to inform treatment planning and in vivo monitoring in thin tissues. Specifically, the measurement of thermal properties, cooling surface contact, tissue thickness, blood flow and phase change with mm to sub mm accuracy are needed. As a proof of principle, we demonstrate that a micro-thermal sensor based on the supported “3ω” technique can achieve this in vitro under idealized conditions in 0.5 to 2 mm thick tissues relevant to cryoablation of the pulmonary vein (PV). To begin with “3ω” sensors were microfabricated onto flat glass as an idealization of a focal probe surface. The sensor was then used to make new measurements of ‘k’ (W/m.K) of porcine PV, esophagus, and phrenic nerve, all needed for PV cryoabalation treatment planning. Further, by modifying the sensor use from traditional to dynamic mode new measurements related to tissue vs. fluid (i.e. water) contact, fluid flow conditions, tissue thickness, and phase change were made. In summary, the in vitro idealized system data presented is promising and warrants future work to integrate and test supported “3ω” sensors on in vivo deployed focal therapy probe surfaces (i.e. balloons or catheters).

  16. Role of scintigraphy in focally abnormal sonograms of fatty livers

    International Nuclear Information System (INIS)

    Lisbona, R.; Mishkin, S.; Derbekyan, V.; Novales-Diaz, J.A.; Roy, A.; Sanders, L.

    1988-01-01

    Fatty infiltration of the liver may cause a range of focal abnormalities on hepatic sonography which may simulate hepatic nodular lesions. Discrete deposits of fat or islands of normal tissue which are uninvolved by fatty infiltration may stand out as potential space-occupying lesions on the sonograms. Twelve patients with such focally abnormal ultrasound images were referred for liver scintigraphy with 133 Xe and /sup 99m/Tc colloidal SPECT studies to clarify the issue. These examinations helped identify, in nine of 12 patients, the innocent nature of the sonographic abnormalities which were simply related to the fat deposition process. Further, [/sup 99m/Tc]RBC scans defined the additional pathologic process in three patients in whom actual space-occupying lesions were indeed present in the liver. Scintigraphy has an important role to play in the understanding of focal hepatic ultrasound abnormalities particularly in unsuspected hepatic steatosis

  17. Role of scintigraphy in focally abnormal sonograms of fatty livers

    Energy Technology Data Exchange (ETDEWEB)

    Lisbona, R.; Mishkin, S.; Derbekyan, V.; Novales-Diaz, J.A.; Roy, A.; Sanders, L.

    1988-06-01

    Fatty infiltration of the liver may cause a range of focal abnormalities on hepatic sonography which may simulate hepatic nodular lesions. Discrete deposits of fat or islands of normal tissue which are uninvolved by fatty infiltration may stand out as potential space-occupying lesions on the sonograms. Twelve patients with such focally abnormal ultrasound images were referred for liver scintigraphy with /sup 133/Xe and /sup 99m/Tc colloidal SPECT studies to clarify the issue. These examinations helped identify, in nine of 12 patients, the innocent nature of the sonographic abnormalities which were simply related to the fat deposition process. Further, (/sup 99m/Tc)RBC scans defined the additional pathologic process in three patients in whom actual space-occupying lesions were indeed present in the liver. Scintigraphy has an important role to play in the understanding of focal hepatic ultrasound abnormalities particularly in unsuspected hepatic steatosis.

  18. The spreading of focal brain edema induced by ultraviolet irradiation

    International Nuclear Information System (INIS)

    Ferszt, R.; Neu, S.; Cervos-Navarro, J.; Sperner, J.

    1978-01-01

    Focal brain edema limited to one cerebral hemisphere was produced by ultraviolet irradiation of the exposed cortex. Tissue water content was determined by the gravimetric method which allows microsampling. Therefore, the spread of edema around the small necrotic area be mapped more precisely than by determination of dry weight which calls for larger samples. As early as 30 min after irradiation, hyperemia and swelling of the brain are observed under the operating microscope. This correlates with venous stasis, hyperemia, and broadened perivascular spaces around venules and large capillaries accompanied by a marked rise in the specific weigth of the tissue. After 4h an edema front can be observed spreading from the perinerotic zone in which there is a marked rise in endothelial cell vesicular activity. Edema reaches maximum levels in the deep white matter at 48h post irradiation with normalisation of the tissue water content after 96h. The velocity at which the edema front spreads from the cortex to the periventricular area lies in the range of 0.25mm/h. Edema reabsorption coincides with signs of retrograde micropinocytosis in endothelial cells. (orig./AJ) [de

  19. The role of executive functioning in memory performance in pediatric focal epilepsy

    Science.gov (United States)

    Sepeta, Leigh N.; Casaletto, Kaitlin Blackstone; Terwilliger, Virginia; Facella-Ervolini, Joy; Sady, Maegan; Mayo, Jessica; Gaillard, William D.; Berl, Madison M.

    2016-01-01

    Objective Learning and memory are essential for academic success and everyday functioning, but the pattern of memory skills and its relationship to executive functioning in children with focal epilepsy is not fully delineated. We address a gap in the literature by examining the relationship between memory and executive functioning in a pediatric focal epilepsy population. Methods Seventy children with focal epilepsy and 70 typically developing children matched on age, intellectual functioning, and gender underwent neuropsychological assessment, including measures of intelligence (WASI/DAS), as well as visual (CMS Dot Locations) and verbal episodic memory (WRAML Story Memory and CVLT-C). Executive functioning was measured directly (WISC-IV Digit Span Backward; CELF-IV Recalling Sentences) and by parent report (Behavior Rating Inventory of Executive Function (BRIEF)). Results Children with focal epilepsy had lower delayed free recall scores than controls across visual and verbal memory tasks (p = 0.02; partial η2 = .12). In contrast, recognition memory performance was similar for patients and controls (p = 0.36; partial η2 = .03). Children with focal epilepsy demonstrated difficulties in working memory (p = 0.02; partial η2 = .08) and planning/organization (p = 0.02) compared to controls. Working memory predicted 9–19% of the variance in delayed free recall for verbal and visual memory; organization predicted 9–10% of the variance in verbal memory. Patients with both left and right focal epilepsy demonstrated more difficulty on verbal versus visual tasks (p = 0.002). Memory performance did not differ by location of seizure foci (temporal vs. extra-temporal, frontal vs. extra-frontal). Significance Children with focal epilepsy demonstrated memory ability within age-level expectations, but delayed free recall was inefficient compared to typically developing controls. Memory difficulties were not related to general cognitive impairment or seizure localization

  20. Spatiotemporal variability of snow depth across the Eurasian continent from 1966 to 2012

    Science.gov (United States)

    Zhong, Xinyue; Zhang, Tingjun; Kang, Shichang; Wang, Kang; Zheng, Lei; Hu, Yuantao; Wang, Huijuan

    2018-01-01

    Snow depth is one of the key physical parameters for understanding land surface energy balance, soil thermal regime, water cycle, and assessing water resources from local community to regional industrial water supply. Previous studies by using in situ data are mostly site specific; data from satellite remote sensing may cover a large area or global scale, but uncertainties remain large. The primary objective of this study is to investigate spatial variability and temporal change in snow depth across the Eurasian continent. Data used include long-term (1966-2012) ground-based measurements from 1814 stations. Spatially, long-term (1971-2000) mean annual snow depths of >20 cm were recorded in northeastern European Russia, the Yenisei River basin, Kamchatka Peninsula, and Sakhalin. Annual mean and maximum snow depth increased by 0.2 and 0.6 cm decade-1 from 1966 through 2012. Seasonally, monthly mean snow depth decreased in autumn and increased in winter and spring over the study period. Regionally, snow depth significantly increased in areas north of 50° N. Compared with air temperature, snowfall had greater influence on snow depth during November through March across the former Soviet Union. This study provides a baseline for snow depth climatology and changes across the Eurasian continent, which would significantly help to better understanding climate system and climate changes on regional, hemispheric, or even global scales.

  1. On-line depth measurement for laser-drilled holes based on the intensity of plasma emission

    Science.gov (United States)

    Ho, Chao-Ching; Chiu, Chih-Mu; Chang, Yuan-Jen; Hsu, Jin-Chen; Kuo, Chia-Lung

    2014-09-01

    The direct time-resolved depth measurement of blind holes is extremely difficult due to the short time interval and the limited space inside the hole. This work presents a method that involves on-line plasma emission acquisition and analysis to obtain correlations between the machining processes and the optical signal output. Given that the depths of laser-machined holes can be estimated on-line using a coaxial photodiode, this was employed in our inspection system. Our experiments were conducted in air under normal atmospheric conditions without gas assist. The intensity of radiation emitted from the vaporized material was found to correlate with the depth of the hole. The results indicate that the estimated depths of the laser-drilled holes were inversely proportional to the maximum plasma light emission measured for a given laser pulse number.

  2. Electrophysiological and pathological study of focal cortical dysplasia

    International Nuclear Information System (INIS)

    Hodozuka, Akira; Hashizume, Kiyotaka; Hayashi, Yoshimitsu; Tanaka, Tatsuya

    2008-01-01

    Clinical and experimental studies on focal cortical dysplasia (FCD) were carried out. For the experimental study, an experimental FCD model of rats was developed. Twenty Wistar rats at 0-2 days after birth were used for the study. Kainic acid (KA) solution was injected stereotaxically into medial and lateral sites of the sensori-motor cortex. Bipolar electrodes were inserted. The behavior of the rats and electroencephalography (EEG) were recorded using a digital video-EEG monitoring system. After observation periods of 1, 2 and 6 months, the rats were perfused for pathological study. FCD was observed adjacent to the site of KA injection in all rats more than one month after the injection. EEG recording demonstrated focal spike discharges in and around the site of injection. However, clinical seizure was not observed. Pathological studies showed decrease in gamma aminobutyric acid (GABA)-A receptors and increase in GABA-B receptors not only in the lesion but also in perilesional areas. Fifteen surgical cases of FCD with intractable epilepsy were included in the clinical study. Neuro-imaging studies including high-resolution MRI and single photon emission computed tomography (SPECT) were performed. Conventional EEG studies demonstrated focal EEG abnormalities with epileptic phenomena. At surgery, intraoperative electrocorticography (ECoG) was performed in order to localize epileptic foci under neuroleptanalgesia. Fourteen patients showed epileptiform discharges on preresection ECoG. All foci in non-eloquent areas were resected. Pathological studies including immunohistochemical staining were performed, and characteristics of the FCD in relation to EEG findings were analyzed. Electrophysiological examination revealed epileptogenecity not only in the lesions but also in perilesional areas. In the lesions, immunohistochemical studies showed decrease in GABA-A receptors and increase in GABA-B receptors in both the lesions and perilesional areas, but N

  3. Pathogenesis of Focal Segmental Glomerulosclerosis

    Directory of Open Access Journals (Sweden)

    Beom Jin Lim

    2016-11-01

    Full Text Available Focal segmental glomerulosclerosis (FSGS is characterized by focal and segmental obliteration of glomerular capillary tufts with increased matrix. FSGS is classified as collapsing, tip, cellular, perihilar and not otherwise specified variants according to the location and character of the sclerotic lesion. Primary or idiopathic FSGS is considered to be related to podocyte injury, and the pathogenesis of podocyte injury has been actively investigated. Several circulating factors affecting podocyte permeability barrier have been proposed, but not proven to cause FSGS. FSGS may also be caused by genetic alterations. These genes are mainly those regulating slit diaphragm structure, actin cytoskeleton of podocytes, and foot process structure. The mode of inheritance and age of onset are different according to the gene involved. Recently, the role of parietal epithelial cells (PECs has been highlighted. Podocytes and PECs have common mesenchymal progenitors, therefore, PECs could be a source of podocyte repopulation after podocyte injury. Activated PECs migrate along adhesion to the glomerular tuft and may also contribute to the progression of sclerosis. Markers of activated PECs, including CD44, could be used to distinguish FSGS from minimal change disease. The pathogenesis of FSGS is very complex; however, understanding basic mechanisms of podocyte injury is important not only for basic research, but also for daily diagnostic pathology practice.

  4. Focal skin defect, limb anomalies and microphthalmia.

    NARCIS (Netherlands)

    Jackson, K.E.; Andersson, H.C.

    2004-01-01

    We describe two unrelated female patients with congenital single focal skin defects, unilateral microphthalmia and limb anomalies. Growth and psychomotor development were normal and no brain malformation was detected. Although eye and limb anomalies are commonly associated, clinical anophthalmia and

  5. Evaluation of Depth of Field for depth perception in DVR

    KAUST Repository

    Grosset, A.V.Pascal; Schott, Mathias; Bonneau, Georges-Pierre; Hansen, Charles D.

    2013-01-01

    In this paper we present a user study on the use of Depth of Field for depth perception in Direct Volume Rendering. Direct Volume Rendering with Phong shading and perspective projection is used as the baseline. Depth of Field is then added to see its impact on the correct perception of ordinal depth. Accuracy and response time are used as the metrics to evaluate the usefulness of Depth of Field. The onsite user study has two parts: static and dynamic. Eye tracking is used to monitor the gaze of the subjects. From our results we see that though Depth of Field does not act as a proper depth cue in all conditions, it can be used to reinforce the perception of which feature is in front of the other. The best results (high accuracy & fast response time) for correct perception of ordinal depth occurs when the front feature (out of the two features users were to choose from) is in focus and perspective projection is used. © 2013 IEEE.

  6. Evaluation of Depth of Field for depth perception in DVR

    KAUST Repository

    Grosset, A.V.Pascal

    2013-02-01

    In this paper we present a user study on the use of Depth of Field for depth perception in Direct Volume Rendering. Direct Volume Rendering with Phong shading and perspective projection is used as the baseline. Depth of Field is then added to see its impact on the correct perception of ordinal depth. Accuracy and response time are used as the metrics to evaluate the usefulness of Depth of Field. The onsite user study has two parts: static and dynamic. Eye tracking is used to monitor the gaze of the subjects. From our results we see that though Depth of Field does not act as a proper depth cue in all conditions, it can be used to reinforce the perception of which feature is in front of the other. The best results (high accuracy & fast response time) for correct perception of ordinal depth occurs when the front feature (out of the two features users were to choose from) is in focus and perspective projection is used. © 2013 IEEE.

  7. How Choice of Depth Horizon Influences the Estimated Spatial Patterns and Global Magnitude of Ocean Carbon Export Flux

    Science.gov (United States)

    Palevsky, Hilary I.; Doney, Scott C.

    2018-05-01

    Estimated rates and efficiency of ocean carbon export flux are sensitive to differences in the depth horizons used to define export, which often vary across methodological approaches. We evaluate sinking particulate organic carbon (POC) flux rates and efficiency (e-ratios) in a global earth system model, using a range of commonly used depth horizons: the seasonal mixed layer depth, the particle compensation depth, the base of the euphotic zone, a fixed depth horizon of 100 m, and the maximum annual mixed layer depth. Within this single dynamically consistent model framework, global POC flux rates vary by 30% and global e-ratios by 21% across different depth horizon choices. Zonal variability in POC flux and e-ratio also depends on the export depth horizon due to pronounced influence of deep winter mixing in subpolar regions. Efforts to reconcile conflicting estimates of export need to account for these systematic discrepancies created by differing depth horizon choices.

  8. Ballistic Target PHD Filter Based on Infrared Focal Plane Ambiguous Observation

    Directory of Open Access Journals (Sweden)

    Wei Zhao

    2017-01-01

    Full Text Available Space-based early warning system, the main detection means of which is passive detection based on focal plane, is an important part of ballistic missile defense system. The focal plane is mainly composed of CCD, and its size can reach the micron level, so the pixel is often regarded as point of no area in image postprocessing. The design of traditional tracking methods is based on this, and the observation based on the focal plane is modeled as the azimuth with random noise. However, this modeling is inaccurate. In the context of space-based detection, CCD cannot be simplified as a point, and its size should be considered. And the corresponding observation cannot be treated as azimuth with random noise. In this paper, the observation based on focal plane is modeled as Unambiguously Generated Ambiguous (UGA measurement. The PHD filter algorithm is redesigned and simplified. The simulation results show that the algorithm based on UGA measurement observation model has better tracking effect compared with that based on traditional observation model. This method provides technical support for more accurate target tracking for space-based early warning system.

  9. Adaptation of spectral distribution of synchrotron radiation to X-ray depth lithography

    International Nuclear Information System (INIS)

    Maid, B.; Ehrfeld, W.; Hormes, J.; Mohr, J.; Muenchmeyer, D.

    1989-05-01

    Plastic microstructures with extremly high aspect ratios can be fabricated by X-ray depth lithography with synchrotron radiation. In order to minimize the expenditure in terms of irradiation the spectrum of the synchrotron radiation source has to be adapted to the irradiation task. It is characterized by the height of the microstructure and the maximum admissible dose ratio permitting the resist to develop in the depth without destruction of the surface as a result of radiation damage. Expenditure in terms of irradiation is minimum if an ideal sharp cutoff filter, profiting from the maximum permissible dose ratio, filters out the long-waved portion of the spectrum without attenuating the intensity of the short-waved portion of the spectrum. By the example of a typical resist-developer system the location of the filter edge was determined at different structural heights for the Bonn synchrotron and the ELSA electron stretching facility (Bonn). To be capable of building the ideal sharp cutoff filter, the thickness of an absorber was adapted for different materials in such a way that the maximum permissible dose ratio was obtained. If a thin reflector foil is used which is hit by glazing radiation, the expenditure in terms of irradiation can be reduced because of the steeper filter characteristic of resists with small maximum dose ratios. The short-waved transmitted beam is used for irradiation, with the filter edge set by the angle between the foil and the beam. The technical feasibility of a reflection filter was demonstrated on the model of a reflector foil consisting of 30 nm titanium on 7.5 μm polyimide substrate by transmission measurements performed at different angles. (orig./HP) [de

  10. Formation of multiple focal spots using a high NA lens with a complex spiral phase mask

    Science.gov (United States)

    Lalithambigai, K.; Anbarasan, P. M.; Rajesh, K. B.

    2014-07-01

    The formation of a transversally polarized beam by transmitting a tightly focused double-ring-shaped azimuthally polarized beam through a complex spiral phase mask and high numerical aperture lens is presented based on vector diffraction theory. The generation of transversally polarized focal spot segment splitting and multiple focal spots is illustrated numerically. Moreover, we found that a properly designed complex spiral phase mask can move the focal spots along the optical axis in the z direction. Therefore, one can achieve a focal segment of two, three or multiple completely transversely polarized focal spots, which finds applications in optical trapping and in material processing technologies.

  11. Mammographic image restoration using maximum entropy deconvolution

    International Nuclear Information System (INIS)

    Jannetta, A; Jackson, J C; Kotre, C J; Birch, I P; Robson, K J; Padgett, R

    2004-01-01

    An image restoration approach based on a Bayesian maximum entropy method (MEM) has been applied to a radiological image deconvolution problem, that of reduction of geometric blurring in magnification mammography. The aim of the work is to demonstrate an improvement in image spatial resolution in realistic noisy radiological images with no associated penalty in terms of reduction in the signal-to-noise ratio perceived by the observer. Images of the TORMAM mammographic image quality phantom were recorded using the standard magnification settings of 1.8 magnification/fine focus and also at 1.8 magnification/broad focus and 3.0 magnification/fine focus; the latter two arrangements would normally give rise to unacceptable geometric blurring. Measured point-spread functions were used in conjunction with the MEM image processing to de-blur these images. The results are presented as comparative images of phantom test features and as observer scores for the raw and processed images. Visualization of high resolution features and the total image scores for the test phantom were improved by the application of the MEM processing. It is argued that this successful demonstration of image de-blurring in noisy radiological images offers the possibility of weakening the link between focal spot size and geometric blurring in radiology, thus opening up new approaches to system optimization

  12. Experimental study on depth of paraffin wax over floating absorber plate in built-in storage solar water heater

    Directory of Open Access Journals (Sweden)

    R Sivakumar

    2015-11-01

    Full Text Available The aim of this article is to study the effect of depth of phase change material over the absorber surface of an integrated collector-storage type flat plate solar water heater. Flat plate solar water heaters are extensively used all over the world to utilize the natural source of solar energy. In order to utilize the solar energy during off-sunshine hours, it is inevitable to store and retain solar thermal energy as long as possible. Here, phase change material is not used for heat storage, but to minimize losses during day and night time only. The depth of phase change material over a fixed depth of water in a solar thermal collector is an important geometric parameter that influences the maximum temperature rise during peak solar irradiation and hence the losses. From the results of the studies for different masses of paraffin wax phase change material layers, the optimum depth corresponding to the maximum heat gain till evening is found to be 2 mm, and the heat retention till the next day morning is found to be 4 mm.

  13. Taxonomy of multi-focal nematode image stacks by a CNN based image fusion approach.

    Science.gov (United States)

    Liu, Min; Wang, Xueping; Zhang, Hongzhong

    2018-03-01

    In the biomedical field, digital multi-focal images are very important for documentation and communication of specimen data, because the morphological information for a transparent specimen can be captured in form of a stack of high-quality images. Given biomedical image stacks containing multi-focal images, how to efficiently extract effective features from all layers to classify the image stacks is still an open question. We present to use a deep convolutional neural network (CNN) image fusion based multilinear approach for the taxonomy of multi-focal image stacks. A deep CNN based image fusion technique is used to combine relevant information of multi-focal images within a given image stack into a single image, which is more informative and complete than any single image in the given stack. Besides, multi-focal images within a stack are fused along 3 orthogonal directions, and multiple features extracted from the fused images along different directions are combined by canonical correlation analysis (CCA). Because multi-focal image stacks represent the effect of different factors - texture, shape, different instances within the same class and different classes of objects, we embed the deep CNN based image fusion method within a multilinear framework to propose an image fusion based multilinear classifier. The experimental results on nematode multi-focal image stacks demonstrated that the deep CNN image fusion based multilinear classifier can reach a higher classification rate (95.7%) than that by the previous multilinear based approach (88.7%), even we only use the texture feature instead of the combination of texture and shape features as in the previous work. The proposed deep CNN image fusion based multilinear approach shows great potential in building an automated nematode taxonomy system for nematologists. It is effective to classify multi-focal image stacks. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Changes on diffusion-weighted MRI with focal motor status epilepticus: case report

    International Nuclear Information System (INIS)

    Loevblad, K.O.; Senn, P.; Zutter, D.; Bassetti, C.; Donati, F.; Loevblad, K.O.; Zeller, O.; Schroth, G.

    2003-01-01

    Transient imaging abnormalities, including changes on diffusion-weighted imaging (DWI), may be seen in focal status epilepticus. The changes on DWI provide an insight into the pathophysiology. We report a 53-year-old man with focal motor status epilepticus involving the left hand, arm and face with focal slowing on EEG. The apparent diffusion coefficients (ADC) were higher in the affected hemisphere than on the other side. At 10 days and 6 weeks after the end of the seizures, we saw normal ADCs and atrophy of the affected hemisphere. We conclude that the MRI findings indicate both cytotoxic and vasogenic oedema during seizure activity and subsequent loss of brain parenchyma. (orig.)

  15. Changes on diffusion-weighted MRI with focal motor status epilepticus: case report

    Energy Technology Data Exchange (ETDEWEB)

    Loevblad, K O [Neuroradiology, Radiodiagnostic, Hopital Cantonal de Geneve HUG, Geneve (Switzerland); Senn, P; Zutter, D; Bassetti, C; Donati, F [Dept. of Neurology, Inselspital, Univ. Hospital, Berne (Switzerland); Loevblad, K O; Zeller, O; Schroth, G [Div. of Neuroradiology, Inselspital, Univ. Hospital, Berne (Switzerland)

    2003-04-01

    Transient imaging abnormalities, including changes on diffusion-weighted imaging (DWI), may be seen in focal status epilepticus. The changes on DWI provide an insight into the pathophysiology. We report a 53-year-old man with focal motor status epilepticus involving the left hand, arm and face with focal slowing on EEG. The apparent diffusion coefficients (ADC) were higher in the affected hemisphere than on the other side. At 10 days and 6 weeks after the end of the seizures, we saw normal ADCs and atrophy of the affected hemisphere. We conclude that the MRI findings indicate both cytotoxic and vasogenic oedema during seizure activity and subsequent loss of brain parenchyma. (orig.)

  16. Efficient Depth Enhancement Using a Combination of Color and Depth Information.

    Science.gov (United States)

    Lee, Kyungjae; Ban, Yuseok; Lee, Sangyoun

    2017-07-01

    Studies on depth images containing three-dimensional information have been performed for many practical applications. However, the depth images acquired from depth sensors have inherent problems, such as missing values and noisy boundaries. These problems significantly affect the performance of applications that use a depth image as their input. This paper describes a depth enhancement algorithm based on a combination of color and depth information. To fill depth holes and recover object shapes, asynchronous cellular automata with neighborhood distance maps are used. Image segmentation and a weighted linear combination of spatial filtering algorithms are applied to extract object regions and fill disocclusion in the object regions. Experimental results on both real-world and public datasets show that the proposed method enhances the quality of the depth image with low computational complexity, outperforming conventional methods on a number of metrics. Furthermore, to verify the performance of the proposed method, we present stereoscopic images generated by the enhanced depth image to illustrate the improvement in quality.

  17. Assessment of Macular Function during Vitrectomy: New Approach Using Intraoperative Focal Macular Electroretinograms.

    Directory of Open Access Journals (Sweden)

    Celso Soiti Matsumoto

    Full Text Available To describe a new technique to record focal macular electroretinograms (FMERGs during vitrectomy to assess macular function.Intraoperative FMERGs (iFMERGs were recorded in ten patients (10 eyes who undergo vitrectomy. iFMERGs were elicited by focal macular stimulation. The stimulus light was directed to the macular area through a 25 gauge (25G glass fiber optic bundle. Background light was delivered through a dual chandelier-type light fiber probe. Focal macular responses elicited with combinations of stimulus and background luminances were analyzed.A stimulus luminance that was approximately 1.75 log units brighter than the background light was able to elicit focal macular responses that were not contaminated by stray light responses. Thus, a stimulus luminance of 160 cd/m2 delivered on a background of 3 cd/m2 elicited iFMEGs from only the stimulated area. This combination of stimulus and background luminances did not elicit a response when the stimulus was projected onto the optic nerve head. The iFMERGs elicited by a 10° stimulus with a duration of 100 ms and an interstimulus interval of 150 ms consisted of an a-, b-, and d-waves, the oscillatory potentials, and the photopic negative response (PhNR.Focal ERGs with all components can be recorded from the macula and other retinal areas during vitreous surgery. This new technique will allow surgeons to assess the function of focal areas of the retina intraoperatively.

  18. Prior task experience and comparable stimulus exposure nullify focal and nonfocal prospective memory retrieval differences.

    Science.gov (United States)

    Hicks, Jason L; Franks, Bryan A; Spitler, Samantha N

    2017-10-01

    We explored the nature of focal versus nonfocal event-based prospective memory retrieval. In the context of a lexical decision task, people received an intention to respond to a single word (focal) in one condition and to a category label (nonfocal) for the other condition. Participants experienced both conditions, and their order was manipulated. The focal instruction condition was a single word presented multiple times. In Experiment 1, the stimuli in the nonfocal condition were different exemplars from a category, each presented once. In the nonfocal condition retrieval was poorer and reaction times were slower during the ongoing task as compared to the focal condition, replicating prior findings. In Experiment 2, the stimulus in the nonfocal condition was a single category exemplar repeated multiple times. When this single-exemplar nonfocal condition followed in time the single-item focal condition, focal versus nonfocal performance was virtually indistinguishable. These results demonstrate that people can modify their stimulus processing and expectations in event-based prospective memory tasks based on experience with the nature of prospective cues and with the ongoing task.

  19. Hiperceratose focal acral associada à hipocromia de dermatóglifos Focal acral hyperkeratosis with hypochromic dermatoglyphics

    Directory of Open Access Journals (Sweden)

    Roberto Rheingantz da Cunha Filho

    2008-10-01

    Full Text Available Hiperceratose focal acral é dermatose rara caracterizada por pápulas ceratóticas acrais que afetam preferencialmente as superfícies marginais das mãos e dos pés, pertencendo ao grupo das hiperceratoses marginais. Apresentamos variante inédita de mulher de 45 anos de idade, branca, dona-de-casa, sem história familiar, com lesões ceratóticas papulosas localizadas nos pés e hipocromia de dermatóglifos na região afetada. Histologicamente apresentou hiperortoceratose, desnível da epiderme (degrau, acantose e hipergranulose. Os tratamentos com ceratolíticos tópicos foram ineficientes, de forma semelhante aos casos descritos na literatura atual.Focal acral hyperkeratosis is a rare condition, characterized by acral keratotic papules that preferably affect hand and foot surfaces, and are included in the spectrum of marginal papular keratodermas. We report an unpublished variant of this condition, the case of a 45-year-old Caucasian woman with acral keratotic papular lesions and hypochromic dermatoglyphics in the feet. Histological examination revealed orthohyperkeratosis, depression of the epidermis, acanthosis and hypergranulosis. Topical treatments with keratolytics were ineffective, similarly to previously described cases.

  20. Fabrication of Transition Edge Sensor Microcalorimeters for X-Ray Focal Planes

    Science.gov (United States)

    Chervenak, James A.; Adams, Joseph S.; Audley, Heather; Bandler, Simon R.; Betancourt-Martinez, Gabriele; Eckart, Megan E.; Finkbeiner, Fred M.; Kelley, Richard L.; Kilbourne, Caroline; Lee, Sang Jun; hide

    2015-01-01

    Requirements for focal planes for x-ray astrophysics vary widely depending on the needs of the science application such as photon count rate, energy band, resolving power, and angular resolution. Transition edge sensor x-ray calorimeters can encounter limitations when optimized for these specific applications. Balancing specifications leads to choices in, for example, pixel size, thermal sinking arrangement, and absorber thickness and material. For the broadest specifications, instruments can benefit from multiple pixel types in the same array or focal plane. Here we describe a variety of focal plane architectures that anticipate science requirements of x-ray instruments for heliophysics and astrophysics. We describe the fabrication procedures that enable each array and explore limitations for the specifications of such arrays, including arrays with multiple pixel types on the same array.

  1. Focal perinatal acquired brain injury - a sonographic study of the course

    Energy Technology Data Exchange (ETDEWEB)

    Franek, A.

    1985-06-01

    A case of a perinatal acquired focal brain lesion is reported, and the process of resorption and healing demonstrated by ultrasound. Within four weeks a cortical area of increased echogenicity was resorbed. After two months, the resulting porencephalic cyst had been transformed into glial tissue of very high echogenicity. The neurologic development of two children with such glial focus was good. These cases demonstrate that porencephalic cysts are not always the final state after resorption of a focal brain lesion. They are no reliable prognostic indicator of poor neurological outcome. Traumatic and complicated delivery, asphyxia and coagulopathy are conditions which have been found several times in connection with a focal brain lesion. In contrast to periventricular injury, prematurity does not seem to be a factor of higher risk.

  2. Power of the Poincare Group: Elucidating the Hidden Symmetries in Focal Conic Domains

    International Nuclear Information System (INIS)

    Alexander, Gareth P.; Chen, Bryan Gin-ge; Matsumoto, Elisabetta A.; Kamien, Randall D.

    2010-01-01

    Focal conic domains are typically the 'smoking gun' by which smectic liquid crystalline phases are identified. The geometry of the equally spaced smectic layers is highly generic but, at the same time, difficult to work with. In this Letter we develop an approach to the study of focal sets in smectics which exploits a hidden Poincare symmetry revealed only by viewing the smectic layers as projections from one-higher dimension. We use this perspective to shed light upon several classic focal conic textures, including the concentric cyclides of Dupin, polygonal textures, and tilt-grain boundaries.

  3. Systemic focal epileptogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Remler, M.P.; Marcussen, W.H.

    1986-01-01

    Rats that receive radiation to 0.25 cc of one cerebral hemisphere are clinically and electroencephalographically normal until there is a breakdown of the blood-brain barrier (BBB) at 3 to 6 months postradiation. This BBB lesion can be detected by transient focal seizure activity produced by the BBB-excluded systemic convulsant bicuculline methiodide. In two rats the seizure activity induced by this one injection was self-sustaining. In seven of 15 other rats tested, the subsequent administration of repeated 2 mg/kg injections created a chronic focus that continued to spike with great frequency for 3 weeks or more without further administration of any convulsant. In three of eight other rats, implanted minipumps delivering 180 micrograms/h of bicuculline methiodide produced self-sustaining epileptic activity.

  4. Wave Loads on Ships Sailing in Restricted Water Depth

    DEFF Research Database (Denmark)

    Vidic-Perunovic, Jelena; Jensen, Jørgen Juncher

    2003-01-01

    depth for a container vessel. The results show that if the water depth is less than two times the draft of the vessel, the wave-induced bending moment becomes significant larger than in deep water with the same sea state description. The peak in the frequency response function for the wave bending......The wave-induced bending moment in ships is the most important sea load parameter for ships larger than 100m in length. Hence, any rational ship design procedure must include a reasonable accurate determination of this load and a large amount of various hydrodynamic formulations have been published......, ranging from semi-empirical formulas to three-dimensional non-linear procedures. A review of the state-of-the art can be found in ISSC.VI.1 (2000). These procedures must be combined with operational and sea state information to predict the probability distribution of the maximum wave-induced bending...

  5. Relation between second-order moment radius of focal spot and near field distribution of laser beam

    International Nuclear Information System (INIS)

    Gao Xueyan; Su Yi; Ye Yidong; Guan Youguang

    2011-01-01

    In order to analyze the effect of aberration of amplitude and phase of laser beam on second-order moment radius of focal spot, based on the Fraunhofer formula for light wave scalar diffraction theory and the definition of second-order moment radius, the general expression for focal spot second-order moment radius depending on the complex amplitude of near field is derived. The second-order moment radius of the focal spot depending on intensity distribution and phase distribution of near field is derived, and its clear physical meaning is described. The second-order moment radius and the divergence angle of focal spot may be easily calculated with the second-order moment radius expression of focal spot. At last, the divergence angles of focal spots of several kinds of Gaussian laser beams are calculated directly, and the results are in accordance with those in the related references. (authors)

  6. Tsunamigenic Ratio of the Pacific Ocean earthquakes and a proposal for a Tsunami Index

    Directory of Open Access Journals (Sweden)

    A. Suppasri

    2012-01-01

    Full Text Available The Pacific Ocean is the location where two-thirds of tsunamis have occurred, resulting in a great number of casualties. Once information on an earthquake has been issued, it is important to understand if there is a tsunami generation risk in relation with a specific earthquake magnitude or focal depth. This study proposes a Tsunamigenic Ratio (TR that is defined as the ratio between the number of earthquake-generated tsunamis and the total number of earthquakes. Earthquake and tsunami data used in this study were selected from a database containing tsunamigenic earthquakes from prior 1900 to 2011. The TR is calculated from earthquake events with a magnitude greater than 5.0, a focal depth shallower than 200 km and a sea depth less than 7 km. The results suggest that a great earthquake magnitude and a shallow focal depth have a high potential to generate tsunamis with a large tsunami height. The average TR in the Pacific Ocean is 0.4, whereas the TR for specific regions of the Pacific Ocean varies from 0.3 to 0.7. The TR calculated for each region shows the relationship between three influential parameters: earthquake magnitude, focal depth and sea depth. The three parameters were combined and proposed as a dimensionless parameter called the Tsunami Index (TI. TI can express better relationship with the TR and with maximum tsunami height, while the three parameters mentioned above cannot. The results show that recent submarine earthquakes had a higher potential to generate a tsunami with a larger tsunami height than during the last century. A tsunami is definitely generated if the TI is larger than 7.0. The proposed TR and TI will help ascertain the tsunami generation risk of each earthquake event based on a statistical analysis of the historical data and could be an important decision support tool during the early tsunami warning stage.

  7. Depth resolution and preferential sputtering in depth profiling of sharp interfaces

    International Nuclear Information System (INIS)

    Hofmann, S.; Han, Y.S.; Wang, J.Y.

    2017-01-01

    Highlights: • Interfacial depth resolution from MRI model depends on sputtering rate differences. • Depth resolution critically depends on the dominance of roughness or atomic mixing. • True (depth scale) and apparent (time scale) depth resolutions are different. • Average sputtering rate approximately yields true from apparent depth resolution. • Profiles by SIMS and XPS are different but similar to surface concentrations. - Abstract: The influence of preferential sputtering on depth resolution of sputter depth profiles is studied for different sputtering rates of the two components at an A/B interface. Surface concentration and intensity depth profiles on both the sputtering time scale (as measured) and the depth scale are obtained by calculations with an extended Mixing-Roughness-Information depth (MRI)-model. The results show a clear difference for the two extreme cases (a) preponderant roughness and (b) preponderant atomic mixing. In case (a), the interface width on the time scale (Δt(16–84%)) increases with preferential sputtering if the faster sputtering component is on top of the slower sputtering component, but the true resolution on the depth scale (Δz(16–84%)) stays constant. In case (b), the interface width on the time scale stays constant but the true resolution on the depth scale varies with preferential sputtering. For similar order of magnitude of the atomic mixing and the roughness parameters, a transition state between the two extremes is obtained. While the normalized intensity profile of SIMS represents that of the surface concentration, an additional broadening effect is encountered in XPS or AES by the influence of the mean electron escape depth which may even cause an additional matrix effect at the interface.

  8. Depth resolution and preferential sputtering in depth profiling of sharp interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, S. [Max Planck Institute for Intelligent Systems (formerly MPI for Metals Research), Heisenbergstrasse 3, D-70569 Stuttgart (Germany); Han, Y.S. [Department of Physics, Shantou University, 243 Daxue Road, Shantou, 515063 Guangdong (China); Wang, J.Y., E-mail: wangjy@stu.edu.cn [Department of Physics, Shantou University, 243 Daxue Road, Shantou, 515063 Guangdong (China)

    2017-07-15

    Highlights: • Interfacial depth resolution from MRI model depends on sputtering rate differences. • Depth resolution critically depends on the dominance of roughness or atomic mixing. • True (depth scale) and apparent (time scale) depth resolutions are different. • Average sputtering rate approximately yields true from apparent depth resolution. • Profiles by SIMS and XPS are different but similar to surface concentrations. - Abstract: The influence of preferential sputtering on depth resolution of sputter depth profiles is studied for different sputtering rates of the two components at an A/B interface. Surface concentration and intensity depth profiles on both the sputtering time scale (as measured) and the depth scale are obtained by calculations with an extended Mixing-Roughness-Information depth (MRI)-model. The results show a clear difference for the two extreme cases (a) preponderant roughness and (b) preponderant atomic mixing. In case (a), the interface width on the time scale (Δt(16–84%)) increases with preferential sputtering if the faster sputtering component is on top of the slower sputtering component, but the true resolution on the depth scale (Δz(16–84%)) stays constant. In case (b), the interface width on the time scale stays constant but the true resolution on the depth scale varies with preferential sputtering. For similar order of magnitude of the atomic mixing and the roughness parameters, a transition state between the two extremes is obtained. While the normalized intensity profile of SIMS represents that of the surface concentration, an additional broadening effect is encountered in XPS or AES by the influence of the mean electron escape depth which may even cause an additional matrix effect at the interface.

  9. Experimental evidence concerning the significant information depth of electron backscatter diffraction (EBSD)

    Energy Technology Data Exchange (ETDEWEB)

    Wisniewski, Wolfgang, E-mail: wolfgang.w@uni-jena.de [Otto-Schott-Institut, Jena University, Fraunhoferstr. 6, 07743 Jena (Germany); Saager, Stefan [Fraunhofer Institute for Organic Electronics, Electron Beam and Plasma Technology FEP, Winterbergstraße 28, 01277 Dresden (Germany); Böbenroth, Andrea [Fraunhofer Institute for the Microstructure of Materials and Systems IMWS, Walter-Huelse-Straße 1, 06120 Halle (Saale) (Germany); Rüssel, Christian [Otto-Schott-Institut, Jena University, Fraunhoferstr. 6, 07743 Jena (Germany)

    2017-02-15

    Experiments concerning the information depth of electron backscatter diffraction (EBSD) are performed on samples featuring an amorphous wedge on a crystalline substrate and a crystalline wedge on an amorphous substrate. The effects of the acceleration voltage and exemplary software settings on the ability to measure through an amorphous layer are presented. Changes in the EBSD-signal could be detected through a ≈142 nm thick layer of amorphous Si while orientation measurements could be performed through a ≈116 nm thick layer when using a voltage of 30 kV. The complexity of the information depth significant to a given EBSD-pattern and the multiple parameters influencing it are discussed. It is suggested that a “core information depth” is significant to high quality patterns while a larger “maximum information depth” becomes relevant when the pattern quality decreases or the sample is inhomogeneous within the information volume, i.e. in the form of partially crystalline materials or crystal layers in the nm scale. - Highlights: • Experimental evidence of the significant information depth of EBSD is presented. • Effects of the voltage and exemplary software settings are discussed. • Dependence of the significant information depth on the pattern quality is proposed. • The information depth may reach up to 142 nm in Si when using a voltage of 30 kV. • The information depth depends on the available technology.

  10. Estimation of foot pressure from human footprint depths using 3D scanner

    Science.gov (United States)

    Wibowo, Dwi Basuki; Haryadi, Gunawan Dwi; Priambodo, Agus

    2016-03-01

    The analysis of normal and pathological variation in human foot morphology is central to several biomedical disciplines, including orthopedics, orthotic design, sports sciences, and physical anthropology, and it is also important for efficient footwear design. A classic and frequently used approach to study foot morphology is analysis of the footprint shape and footprint depth. Footprints are relatively easy to produce and to measure, and they can be preserved naturally in different soils. In this study, we need to correlate footprint depth with corresponding foot pressure of individual using 3D scanner. Several approaches are used for modeling and estimating footprint depths and foot pressures. The deepest footprint point is calculated from z max coordinate-z min coordinate and the average of foot pressure is calculated from GRF divided to foot area contact and identical with the average of footprint depth. Evaluation of footprint depth was found from importing 3D scanner file (dxf) in AutoCAD, the z-coordinates than sorted from the highest to the lowest value using Microsoft Excel to make footprinting depth in difference color. This research is only qualitatif study because doesn't use foot pressure device as comparator, and resulting the maximum pressure on calceneus is 3.02 N/cm2, lateral arch is 3.66 N/cm2, and metatarsal and hallux is 3.68 N/cm2.

  11. The coefficient of friction of chrysotile gouge at seismogenic depths

    Science.gov (United States)

    Moore, Diane E.; Lockner, D.A.; Tanaka, H.; Iwata, K.

    2004-01-01

    We report new strength data for the serpentine mineral chrysotile at effective normal stresses, ??sn between 40 and 200 MPa in the temperature range 25??-280??C. Overall, the coefficient of friction, ?? (= shear stress/effective normal stress) of water-saturated chrysotile gouge increases both with increasing temperature and ??sn, but the rates vary and the temperature-related increases begin at ???100??C. As a result, a frictional strength minimum (?? = 0.1) occurs at low ??sn at about 100??C. Maximum strength (?? = 0.55) results from a combination of high normal stress and high temperature. The low-strength region is characterized by velocity strengthening and the high-strength region by velocity-weakening behavior. Thoroughly dried chrysotile has ?? = 0.7 and is velocity-weakening. The frictional properties of chrysolite can be explained in its tendency to adsorb large amounts of water that acts as a lubricant during shear. The water is progressively driven off the fiber surfaces with increasing temperature and pressure, causing chrysotile to approach its dry strength. Depth profiles for a chrysotile-lined fault constructed from these data would pass through a strength minimum at ???3 km depth, where sliding should be stable. Below that depth, strength increases rapidly as does the tendency for unstable (seismic) slip. Such a trend would not have been predicted from the room-temperature data. These results therefore illustrate the potential hazards of extrapolating room-temperature friction data to predict fault zone behavior at depth. This depth profile for chrysotile is consistent with the pattern of slip on the Hayward fault, which creeps aseismically at shallow depths but which may be locked below 5 km depth. ?? 2004 by V. H. Winston and Son, Inc. All rights reserved.

  12. Stress rotation across the Cascadia megathrust requires a weak subduction plate boundary at seismogenic depths

    Science.gov (United States)

    Li, Duo; McGuire, Jeffrey J.; Liu, Yajing; Hardebeck, Jeanne L.

    2018-03-01

    The Mendocino Triple Junction region is the most seismically active part of the Cascadia Subduction Zone. The northward moving Pacific plate collides with the subducting Gorda plate causing intense internal deformation within it. Here we show that the stress field rotates rapidly with depth across the thrust interface from a strike-slip regime within the subducting plate, reflecting the Pacific plate collision, to a thrust regime in the overriding plate. We utilize a dense focal mechanism dataset, including observations from the Cascadia Initiative ocean bottom seismograph experiment, to constrain the stress orientations. To quantify the implications of this rotation for the strength of the plate boundary, we designed an inversion that solves for the absolute stress tensors in a three-layer model subject to assumptions about the strength of the subducting mantle. Our results indicate that the shear stress on the plate boundary fault is likely no more than about ∼50 MPa at ∼20 km depth. Regardless of the assumed mantle strength, we infer a relatively weak megathrust fault with an effective friction coefficient of ∼0 to 0.2 at seismogenic depths. Such a low value for the effective friction coefficient requires a combination of high fluid pressures and/or fault-zone minerals with low inherent friction in the region where a great earthquake is expected in Cascadia.

  13. Stress rotation across the Cascadia megathrust requires a weak subduction plate boundary at seismogenic depths

    Science.gov (United States)

    Li, Duo; McGuire, Jeffrey J.; Liu, Yajing; Hardebeck, Jeanne L.

    2018-01-01

    The Mendocino Triple Junction region is the most seismically active part of the Cascadia Subduction Zone. The northward moving Pacific plate collides with the subducting Gorda plate causing intense internal deformation within it. Here we show that the stress field rotates rapidly with depth across the thrust interface from a strike-slip regime within the subducting plate, reflecting the Pacific plate collision, to a thrust regime in the overriding plate. We utilize a dense focal mechanism dataset, including observations from the Cascadia Initiative ocean bottom seismograph experiment, to constrain the stress orientations. To quantify the implications of this rotation for the strength of the plate boundary, we designed an inversion that solves for the absolute stress tensors in a three-layer model subject to assumptions about the strength of the subducting mantle. Our results indicate that the shear stress on the plate boundary fault is likely no more than about ∼50 MPa at ∼20 km depth. Regardless of the assumed mantle strength, we infer a relatively weak megathrust fault with an effective friction coefficient of ∼0 to 0.2 at seismogenic depths. Such a low value for the effective friction coefficient requires a combination of high fluid pressures and/or fault-zone minerals with low inherent friction in the region where a great earthquake is expected in Cascadia.

  14. Increased calcineurin expression after pilocarpine-induced status epilepticus is associated with brain focal edema and astrogliosis.

    Science.gov (United States)

    Liu, Jinzhi; Li, Xiaolin; Chen, Liguang; Xue, Ping; Yang, Qianqian; Wang, Aihua

    2015-07-28

    Calcineurin plays an important role in the development of neuronal excitability, modulation of receptor's function and induction of apoptosis in neurons. It has been established in kindling models that status epilepticus induces brain focal edema and astrocyte activation. However, the role of calcineurin in brain focal edema and astrocyte activation in status epilepticus has not been fully understood. In this study, we employed a model of lithium-pilocarpine-induced status epilepticus and detected calcineurin expression in hippocampus by immunoblotting, brain focal edema by non-invasive magnetic resonance imaging (MRI-7T) and astrocyte expression by immunohistochemistry. We found that the brain focal edema was seen at 24 h after status epilepticus, and astrocyte expression was obviously seen at 7 d after status epilepticus. Meanwhile, calcineurin expression was seen at24 h and retained to 7 d after status epilepticus. A FK506, a calcineurin inhibitor, remarkably suppressed the status epilepticus-induced brain focal edema and astrocyte expression. Our data suggested that calcineurin overexpression plays a very important role in brain focal edema and astrocyte expression. Therefore, calcineurin may be a novel candidate for brain focal edema occurring and intracellular trigger of astrogliosis in status epilepticus.

  15. Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

    Science.gov (United States)

    Newman, Kevin Edward; Belikov, Ruslan; Guyon, Olivier; Balasubramanian, Kunjithapatham; Wilson, Dan

    2013-01-01

    Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

  16. Opto-mechanical design and development status of an all spherical five lenses focal reducer for the 2.3 m Thai National Telescope

    Science.gov (United States)

    Buisset, Christophe; Prasit, Apirat; Lépine, Thierry; Poshyachinda, Saran; Soonthornthum, Boonrucksar; Deboos, Alexis

    2016-07-01

    The National Astronomical Research Institute (NARIT) is currently developing an all spherical five lenses focal reducer to image a FOV circular of diameter Δθ = 14.6' on the 4K camera with a pixel scale equal to 0.42''/pixel. The spatial resolution will be better than 1.2'' over the full visible spectral domain [400 nm, 800 nm]. The relative irradiance between the ghost and the science images will be lower than 10-4. The maximum distortion will be lower than 1% and the maximum angle of incidence on the filters will be equal to 8°. The focal reducer comprises 1 doublet L1 located at the fork entrance and 1 triplet L2 located in front of the camera. The doublet L1 will be mounted on a tip-tilt mount placed on a robotic sliding rail. L1 will thus be placed in the optical path during the observations with the 4K camera and will be removed during the observations with the other instruments. The triplet L2 will be installed on the instrument cube in front of the camera equipped with the filter wheel. The glass will be manufactured in a specialized company, the mechanical parts will be manufactured by using the NARIT Computer Numerical Control machine and the lenses will be integrated at NARIT. In this paper, we describe the optical and mechanical designs and we present the geometrical performance, the transmission budget and the results of the stray light analyses.

  17. Knee Joint Kinetics in Relation to Commonly Prescribed Squat Loads and Depths

    Science.gov (United States)

    Cotter, Joshua A.; Chaudhari, Ait M.; Jamison, Steve T.; Devor, Steven T.

    2014-01-01

    Controversy exists regarding the safety and performance benefits of performing the squat exercise to depths beyond 90° of knee flexion. Our aim was to compare the net peak external knee flexion moments (pEKFM) experienced over typical ranges of squat loads and depths. Sixteen recreationally trained males (n = 16; 22.7 ± 1.1 yrs; 85.4 ± 2.1 kg; 177.6 ± 0.96 cm; mean ± SEM) with no previous lower limb surgeries or other orthopedic issues and at least one year of consistent resistance training experience while utilizing the squat exercise performed single repetition squat trials in a random order at squat depths of above parallel, parallel, and below parallel. Less than one week before testing, one repetition maximum (1RM) values were found for each squat depth. Subsequent testing required subjects to perform squats at the three depths with three different loads: unloaded, 50% 1RM, and 85% 1RM (nine total trials). Force platform and kinematic data were collected to calculate pEKFM. To assess differences among loads and depths, a two-factor (load and depth) repeated-measures ANOVA with significance set at the P Squat 1RM significantly decreased 13.6% from the above parallel to parallel squat and another 3.6% from the parallel to the below parallel squat (P squat depth and load were increased (P ≤ 0.02). Slopes of pEKFM were greater from unloaded to 50% 1RM than when progressing from 50% to 85% 1RM (P squat loads used with increasing depths are not enough to offset increases in pEKFM. PMID:23085977

  18. Technique for the focal-length measurement of positive lenses using Fizeau interferometry

    International Nuclear Information System (INIS)

    Pavan Kumar, Yeddanapudi; Chatterjee, Sanjib

    2009-01-01

    We present what we believe is a new technique for the focal-length measurement of positive lenses using Fizeau interferometery. The technique utilizes the Gaussian lens equation. The image distance is measured interferometrically in terms of the radius of curvature of the image-forming wavefront emerging from the lens. The radii of curvature of the image-forming wavefronts corresponding to two different axial object positions of known separation are measured. The focal length of the lens is determined by solving the equations obtained using the Gaussian lens equation for the two object positions. Results obtained for a corrected doublet lens of a nominal focal length of 200.0 mm with a measurement uncertainty of ±2.5% is presented

  19. Diagnostic Criteria on 18F-FDG PET/CT for Differentiating Benign from Malignant Focal Hypermetabolic Lesions of Parotid Gland

    International Nuclear Information System (INIS)

    Park, Soo Bin; Choi, Joon Young; Lee, Eun Jeong; Yoo, Jang; Cheon, Miju; Cho, Suk Kyong; Choe, Yearn Seong; Lee, Kyung-Han; Kim, Byung-Tae

    2012-01-01

    We investigated PET/CT diagnostic criteria for differentiating benign from malignant parotid lesions with focal 18 F-FDG uptake. The subjects of the study were 272 patients who exhibited focal 18 F-FDG uptake of the parotid gland. Sixty-eight pathologically confirmed parotid lesions from 67 patients were included. The maximum SUV (SUVmax), uptake patterns (homogeneous vs. heterogeneous), size measured by CT, maximum Housfield units (HUmax) and margins on CT (well vs. ill defined) of each parotid lesion on PET/CT images were compared with final diagnoses. Thirty- two parotid lesions were histologically proven to be malignant. There were significant differences in uptake patterns (cancer incidence, heterogeneous:homogeneous=79.2%:29.5%, p<0.0001) and margins on CT (cancer incidence, ill:well defined=84.4%:13.3%, p<0.0001) between benign and malignant lesions. The cancer risks of parotid lesions were 89.5% with heterogeneous uptake and ill-defined margins, 70.6% with heterogeneous uptake or ill-defined margins (no overlap in subjects) and 9.3% with homogeneous uptake and well-defined margins (p<0.0001). When any lesion with heterogeneous uptake or ill-defined margins was regarded as malignant, the sensitivity, positive predictive value, negative predictive value and accuracy were 90.6% (29/32) and 85.6% (58/68), respectively. For predicting malignancy, combined PET/CT criteria showed better sensitivity, NPV and accuracy than PET-only criteria, and had a tendency to have more accurate results than CT-only criteria, and had a tendency to have more accurate results than CT-only criteria. There were no significant differences in SUVmax, size or HUmax between benign and malignant lesions. Uptake patterns and margins on CT are useful PET/CT diagnostic criteria for differentiating benign from malignant lesions

  20. Landsat 9 OLI 2 focal plane subsystem: design, performance, and status

    Science.gov (United States)

    Malone, Kevin J.; Schrein, Ronald J.; Bradley, M. Scott; Irwin, Ronda; Berdanier, Barry; Donley, Eric

    2017-09-01

    The Landsat 9 mission will continue the legacy of Earth remote sensing that started in 1972. The Operational Land Imager 2 (OLI 2) is one of two instruments on the Landsat 9 satellite. The OLI 2 instrument is essentially a copy of the OLI instrument flying on Landsat 8. A key element of the OLI 2 instrument is the focal plane subsystem, or FPS, which consists of the focal plane array (FPA), the focal plane electronics (FPE) box, and low-thermal conductivity cables. This paper presents design details of the OLI 2 FPS. The FPA contains 14 critically-aligned focal plane modules (FPM). Each module contains 6 visible/near-IR (VNIR) detector arrays and three short-wave infrared (SWIR) arrays. A complex multi-spectral optical filter is contained in each module. Redundant pixels for each array provide exceptional operability. Spare detector modules from OLI were recharacterized after six years of storage. Radiometric test results are presented and compared with data recorded in 2010. Thermal, optical, mechanical and structural features of the FPA will be described. Special attention is paid to the thermal design of the FPA since thermal stability is crucial to ensuring low-noise and low-drift operation of the detectors which operate at -63°C. The OLI 2 FPE provides power, timing, and control to the focal plane modules. It also digitizes the video data and formats it for the solid-state recorder. Design improvements to the FPA-FPE cables will be discussed and characterization data will be presented. The paper will conclude with the status of the flight hardware assembly and testing.

  1. Impact of region contouring variability on image-based focal therapy evaluation

    Science.gov (United States)

    Gibson, Eli; Donaldson, Ian A.; Shah, Taimur T.; Hu, Yipeng; Ahmed, Hashim U.; Barratt, Dean C.

    2016-03-01

    Motivation: Focal therapy is an emerging low-morbidity treatment option for low-intermediate risk prostate cancer; however, challenges remain in accurately delivering treatment to specified targets and determining treatment success. Registered multi-parametric magnetic resonance imaging (MPMRI) acquired before and after treatment can support focal therapy evaluation and optimization; however, contouring variability, when defining the prostate, the clinical target volume (CTV) and the ablation region in images, reduces the precision of quantitative image-based focal therapy evaluation metrics. To inform the interpretation and clarify the limitations of such metrics, we investigated inter-observer contouring variability and its impact on four metrics. Methods: Pre-therapy and 2-week-post-therapy standard-of-care MPMRI were acquired from 5 focal cryotherapy patients. Two clinicians independently contoured, on each slice, the prostate (pre- and post-treatment) and the dominant index lesion CTV (pre-treatment) in the T2-weighted MRI, and the ablated region (post-treatment) in the dynamic-contrast- enhanced MRI. For each combination of clinician contours, post-treatment images were registered to pre-treatment images using a 3D biomechanical-model-based registration of prostate surfaces, and four metrics were computed: the proportion of the target tissue region that was ablated and the target:ablated region volume ratio for each of two targets (the CTV and an expanded planning target volume). Variance components analysis was used to measure the contribution of each type of contour to the variance in the therapy evaluation metrics. Conclusions: 14-23% of evaluation metric variance was attributable to contouring variability (including 6-12% from ablation region contouring); reducing this variability could improve the precision of focal therapy evaluation metrics.

  2. Hemopexin induces neuroprotection in the rat subjected to focal cerebral ischemia.

    Science.gov (United States)

    Dong, Beibei; Cai, Min; Fang, Zongping; Wei, Haidong; Zhu, Fangyun; Li, Guochao; Dong, Hailong; Xiong, Lize

    2013-06-10

    The plasma protein hemopexin (HPX) exhibits the highest binding affinity to free heme. In vitro experiments and gene-knock out technique have suggested that HPX may have a neuroprotective effect. However, the expression of HPX in the brain was not well elucidated and its expression after cerebral ischemia-reperfusion injury was also poorly studied. Furthermore, no in vivo data were available on the effect of HPX given centrally on the prognosis of focal cerebral ischemia. In the present study, we systematically investigated expression of HPX in normal rat brain by immunofluorescent staining. The results showed that HPX was mainly expressed in vascular system and neurons, as well as in a small portion of astrocytes adjacent to the vessels in normal rat brain. Further, we determined the role of HPX in the process of focal cerebral ischemic injury and explored the effects of HPX treatment in a rat model of transient focal cerebral ischemia. After 2 h' middle cerebral artery occlusion (MCAO) followed by 24 h' reperfusion, the expression of HPX was increased in the neurons and astrocytes in the penumbra area, as demonstrated by immunohistochemistry and Western blot techniques. Intracerebroventricular injection of HPX at the onset of reperfusion dose-dependently reduced the infarct volumes and improved measurements of neurological function of the rat subjected to transient focal cerebral ischemia. The neuroprotective effects of HPX sustained for up to 7 days after experiments. Our study provides a new insight into the potential neuroprotective role of HPX as a contributing factor of endogenous protective mechanisms against focal cerebral ischemia injury, and HPX might be developed as a potential agent for treatment of ischemic stroke.

  3. Real-time depth monitoring and control of laser machining through scanning beam delivery system

    International Nuclear Information System (INIS)

    Ji, Yang; Grindal, Alexander W; Fraser, James M; Webster, Paul J L

    2015-01-01

    Scanning optics enable many laser applications in manufacturing because their low inertia allows rapid movement of the process beam across the sample. We describe our method of inline coherent imaging for real-time (up to 230 kHz) micron-scale (7–8 µm axial resolution) tracking and control of laser machining depth through a scanning galvo-telecentric beam delivery system. For 1 cm trench etching in stainless steel, we collect high speed intrapulse and interpulse morphology which is useful for further understanding underlying mechanisms or comparison with numerical models. We also collect overall sweep-to-sweep depth penetration which can be used for feedback depth control. For trench etching in silicon, we show the relationship of etch rate with average power and scan speed by computer processing of depth information without destructive sample post-processing. We also achieve three-dimensional infrared continuous wave (modulated) laser machining of a 3.96 × 3.96 × 0.5 mm 3 (length × width × maximum depth) pattern on steel with depth feedback. To the best of our knowledge, this is the first successful demonstration of direct real-time depth monitoring and control of laser machining with scanning optics. (paper)

  4. Imaging patterns and focal lesions in fatty liver: a pictorial review.

    Science.gov (United States)

    Venkatesh, Sudhakar K; Hennedige, Tiffany; Johnson, Geoffrey B; Hough, David M; Fletcher, Joel G

    2017-05-01

    Non-alcoholic fatty liver disease is the most common cause of chronic liver disease and affects nearly one-third of US population. With the increasing trend of obesity in the population, associated fatty change in the liver will be a common feature observed in imaging studies. Fatty liver causes changes in liver parenchyma appearance on imaging modalities including ultrasound, computed tomography (CT), and magnetic resonance imaging (MRI) and may affect the imaging characteristics of focal liver lesions (FLLs). The imaging characteristics of FLLs were classically described in a non-fatty liver. In addition, focal fatty change and focal fat sparing may also simulate FLLs. Knowledge of characteristic patterns of fatty change in the liver (diffuse, geographical, focal, subcapsular, and perivascular) and their impact on the detection and characterization of FLL is therefore important. In general, fatty change may improve detection of FLLs on MRI using fat suppression sequences, but may reduce sensitivity on a single-phase (portal venous) CT and conventional ultrasound. In patients with fatty liver, MRI is generally superior to ultrasound and CT for detection and characterization of FLL. In this pictorial essay, we describe the imaging patterns of fatty change in the liver and its effect on detection and characterization of FLLs on ultrasound, CT, MRI, and PET.

  5. Mesophotic coral depth acclimatization is a function of host-specific symbiont physiology

    KAUST Repository

    Ziegler, Maren

    2015-02-06

    Mesophotic coral ecosystems receive increasing attention owing to their potential as deep coral refuges in times of global environmental change. Here, the mechanisms of coral holobiont photoacclimatization over a 60 m depth gradient in the central Red Sea were examined for the four coral genera Porites, Leptoseris, Pachyseris, and Podabacia. General acclimatization strategies were common to all host-symbiont combinations, e.g., Symbiodinium cell densities and photoprotective (PP) to light-harvesting pigment ratios both significantly decreased with water depth. Porites harbored Symbiodinium type C15 over the whole 60 m depth range, while Pachyseris and Podabacia had limited vertical distributions and hosted mainly Symbiodinium type C1. Symbiodinium type C15 had generally higher xanthophyll de-epoxidation rates and lower maximum quantum yields than C1, and also exhibited a strong photoacclimatory signal over depth that relates to the large distribution range of Porites. Interestingly, the coral host had an effect on Symbiodinium pigment composition. When comparing Symbiodinium type C1 in Podabacia and Pachyseris, the ß-carotene chl a−1, the peridinin chl a−1, and diadinoxanthin chl a−1 ratios were significantly different between host species. Our data support a view that depth acclimatization of corals in the mesophotics is facilitated by Symbiodinium physiology, which in turn is host-specific.

  6. Mesophotic coral depth acclimatization is a function of host-specific symbiont physiology

    KAUST Repository

    Ziegler, Maren; Roder, Cornelia; Bü chel, Claudia; Voolstra, Christian R.

    2015-01-01

    Mesophotic coral ecosystems receive increasing attention owing to their potential as deep coral refuges in times of global environmental change. Here, the mechanisms of coral holobiont photoacclimatization over a 60 m depth gradient in the central Red Sea were examined for the four coral genera Porites, Leptoseris, Pachyseris, and Podabacia. General acclimatization strategies were common to all host-symbiont combinations, e.g., Symbiodinium cell densities and photoprotective (PP) to light-harvesting pigment ratios both significantly decreased with water depth. Porites harbored Symbiodinium type C15 over the whole 60 m depth range, while Pachyseris and Podabacia had limited vertical distributions and hosted mainly Symbiodinium type C1. Symbiodinium type C15 had generally higher xanthophyll de-epoxidation rates and lower maximum quantum yields than C1, and also exhibited a strong photoacclimatory signal over depth that relates to the large distribution range of Porites. Interestingly, the coral host had an effect on Symbiodinium pigment composition. When comparing Symbiodinium type C1 in Podabacia and Pachyseris, the ß-carotene chl a−1, the peridinin chl a−1, and diadinoxanthin chl a−1 ratios were significantly different between host species. Our data support a view that depth acclimatization of corals in the mesophotics is facilitated by Symbiodinium physiology, which in turn is host-specific.

  7. Core biopsy as a simple and effective diagnostic tool in head and neck focal myositis.

    Science.gov (United States)

    Tan, Chun Yee; Chong, Sheldon; Shaw, Chi-Kee Leslie

    2015-12-01

    Most unilateral head and neck masses are benign, although malignancy is a possibility in some cases. However, there are other rare causes of unilateral neck masses, such as focal myositis, which is a rare, benign condition belonging to the family of inflammatory pseudotumors of the skeletal muscles, with rare presentations in the head and neck region. Focal myositis presents as a rapidly enlarging neck mass that can be misdiagnosed by fine-needle aspiration biopsy and/or radiologic imaging as either an infective or a neoplastic process. To date, there are only 5 reported cases of adult focal myositis of the sternocleidomastoid muscle in the medical literature. In this article, the authors present 2 cases involving patients with focal myositis of the sternocleidomastoid muscle that were successfully diagnosed with core-needle biopsy and managed conservatively. The pros and cons of fine-needle aspiration biopsy and core-needle biopsy are discussed. Based on the authors' results, fine-needle aspiration biopsy universally fails to provide the diagnosis of focal myositis. In contrast, core-needle biopsy successfully diagnosed focal myositis in both of our patients. Both of them had complete resolution with conservative management.

  8. Comparison of Photopic Negative Response of Full-Field and Focal Electroretinograms in Detecting Glaucomatous Eyes

    Directory of Open Access Journals (Sweden)

    Shigeki Machida

    2011-01-01

    Full Text Available Purpose. To compare the photopic negative response (PhNR of the full-field electroretinogram (ERG to the PhNR of the focal ERGs in detecting glaucoma. Methods. One hundred and three eyes with glaucoma and 42 normal eyes were studied. Full-field ERGs were elicited by red stimuli on a blue background. The focal ERGs were elicited by a 15∘ white stimulus spot centered on the macula, the superotemporal or the inferotemporal areas of the macula. Results. In early glaucoma, the areas under the receiver operating characteristic curves (AUCs were significantly larger for the focal PhNR (0.863–0.924 than those for the full-field PhNR (0.666–0.748 (P<.05. The sensitivity was significantly higher for the focal PhNR than for the full-field PhNR in early (P<.01 and intermediate glaucoma (P<.05. In advanced glaucoma, there was no difference in the AUCs and sensitivities between the focal and full-field PhNRs. Conclusions. The focal ERG has the diagnostic ability with higher sensitivity in detecting early and intermediate glaucoma than the full-field ERG.

  9. Oral focal epithelial hyperplasia: report of three cases.

    Science.gov (United States)

    Ghalayani, Parichehr; Tavakoli, Payam; Eftekhari, Mehdi; Haghighi, Mohammad Akhondzadeh

    2015-01-01

    Focal epithelial hyperplasia or Heck's disease is an infrequent asymptomatic condition caused by human papillomavirus types 13 or 32 affecting the mucous membrane of the mouth and is commonly seen in young individuals. Firstly, it was described in Indians and Eskimos, but it exists in various populations. We present three cases of Heck's disease in an Afghan immigrant family group living in Iran that seem to have familial predominance. The disease was identified as oral focal epithelial hyperplasia on the basis of histopathologic and clinical findings. The lesions were reduced significantly after 4 months of good oral hygiene. Dentists should be familiar with the clinical manifestations of these types of lesions that affect the oral cavity. In fact, histopathologic assessment and clinical observation are necessary to establish the diagnosis.

  10. Focal frontal epileptiform discharges in a patient with eyelid myoclonia and absence seizures

    Directory of Open Access Journals (Sweden)

    Satoru Takahashi

    2015-01-01

    Full Text Available Eyelid myoclonia with absences is classified as a unique type of generalized seizure. Its pathogenesis is proposed to involve the functional abnormalities in cortical–subcortical networks. Here, we describe the case of a 7-year-old boy who had eyelid myoclonia with absences, along with focal motor seizures. Video-EEG monitoring demonstrated eyelid myoclonia associated with 4- to 5-Hz generalized polyspike–waves preceded by focal frontal discharges. Interictal EEG showed focal epileptiform discharges over the frontal regions. Our case suggests an important role of the frontal lobe in the generation of eyelid myoclonia with absences.

  11. Extended depth of focus adaptive optics spectral domain optical coherence tomography

    Science.gov (United States)

    Sasaki, Kazuhiro; Kurokawa, Kazuhiro; Makita, Shuichi; Yasuno, Yoshiaki

    2012-01-01

    We present an adaptive optics spectral domain optical coherence tomography (AO-SDOCT) with a long focal range by active phase modulation of the pupil. A long focal range is achieved by introducing AO-controlled third-order spherical aberration (SA). The property of SA and its effects on focal range are investigated in detail using the Huygens-Fresnel principle, beam profile measurement and OCT imaging of a phantom. The results indicate that the focal range is extended by applying SA, and the direction of extension can be controlled by the sign of applied SA. Finally, we demonstrated in vivo human retinal imaging by altering the applied SA. PMID:23082278

  12. Focal plane AIT sequence: evolution from HRG-Spot 5 to Pleiades HR

    Science.gov (United States)

    Le Goff, Roland; Pranyies, Pascal; Toubhans, Isabelle

    2017-11-01

    Optical and geometrical image qualities of Focal Planes, for "push-broom" high resolution remote sensing satellites, require the implementation of specific means and methods for the AIT sequence. Indeed the geometric performances of the focal plane mainly axial focusing and transverse registration, are duly obtained on the basis of adjustment, setting and measurement of optical and CCD components with an accuracy of a few microns. Since the end of the 1970s, EADS-SODERN has developed a series of detection units for earth observation instruments like SPOT and Helios. And EADS-SODERN is now responsible for the development of the Pleiades High Resolution Focal Plane assembly. This paper presents the AIT sequences. We introduce all the efforts, innovative solutions and improvements made on the assembly facilities to match the technical evolutions and breakthrough of the Pleiades HR FP concept in comparison with the previous High Resolution Geometric SPOT 5 Focal Plane. The main evolution drivers are the implementation of strip filters and the realization of 400 mm continuous retinas. For Pleiades HR AIT sequence, three specific integration and measuring benches, corresponding with the different assembly stages, are used: a 3-D non-contact measurement machine for the assembly of detection module, a 3-D measurement machine for mirror integration on the main Focal Plane SiC structure, and a 3-D geometric coordinates control bench to focus detection module lines and to ensure they are well registered together.

  13. Focal fatty infiltration of the liver: demonstration by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Wenker, J.C.; Baker, M.K.; Ellis, J.H.; Glant, M.D.

    1984-01-01

    Focal fatty infiltration of the liver is a recently recognized yet poorly understood entity, which has become more apparent since the onset of widespread computed tomographic (CT) scanning. Recent reports have suggested that magnetic resonance imaging (MRI) may not be sensitive in the evaluation of diffuse fatty liver. A case is presented in which MRI was as sensitive as CT and sonography in the demonstration of focal fatty change within the liver

  14. Continental lithospheric subduction and intermediate-depth seismicity: Constraints from S-wave velocity structures in the Pamir and Hindu Kush

    Science.gov (United States)

    Li, Wei; Chen, Yun; Yuan, Xiaohui; Schurr, Bernd; Mechie, James; Oimahmadov, Ilhomjon; Fu, Bihong

    2018-01-01

    The Pamir has experienced more intense deformation and shortening than Tibet, although it has a similar history of terrane accretion. Subduction as a primary way to accommodate lithospheric shortening beneath the Pamir has induced the intermediate-depth seismicity, which is rare in Tibet. Here we construct a 3D S-wave velocity model of the lithosphere beneath the Pamir by surface wave tomography using data of the TIPAGE (Tien Shan-Pamir Geodynamic program) and other seismic networks in the area. We imaged a large-scale low velocity anomaly in the crust at 20-50 km depth in the Pamir overlain by a high velocity anomaly at a depth shallower than 15 km. The high velocity anomalies colocate with exposed gneiss domes, which may imply a similar history of crustal deformation, partial melting and exhumation in the hinterland, as has occurred in the Himalaya/Tibet system. At mantle depths, where the intermediate-depth earthquakes are located, a low velocity zone is clearly observed extending to about 180 km and 150 km depth in the Hindu Kush and eastern Pamir, respectively. Moreover, the geometry of the low-velocity anomaly suggests that lower crustal material has been pulled down into the mantle by the subducting Asian and Indian lithospheric mantle beneath the Pamir and Hindu Kush, respectively. Metamorphic processes in the subducting lower crust may cause the intermediate-depth seismicity down to 150-180 km depth beneath the Pamir and Hindu Kush. We inverted focal mechanisms in the seismic zone for the stress field. Differences in the stress field between the upper and lower parts of the Indian slab imply that subduction and detachment of the Indian lithosphere might cause intense seismicity associated with the thermal shear instability in the deep Hindu Kush.

  15. Next generation sub-millimeter wave focal plane array coupling concepts: an ESA TRP project to develop multichroic focal plane pixels for future CMB polarization experiments

    Science.gov (United States)

    Trappe, N.; Bucher, M.; De Bernardis, P.; Delabrouille, J.; Deo, P.; DePetris, M.; Doherty, S.; Ghribi, A.; Gradziel, M.; Kuzmin, L.; Maffei, B.; Mahashabde, S.; Masi, S.; Murphy, J. A.; Noviello, F.; O'Sullivan, C.; Pagano, L.; Piacentini, F.; Piat, M.; Pisano, G.; Robinson, M.; Stompor, R.; Tartari, A.; van der Vorst, M.; Verhoeve, P.

    2016-07-01

    The main objective of this activity is to develop new focal plane coupling array concepts and technologies that optimise the coupling from reflector optics to the large number of detectors for next generation sub millimetre wave telescopes particularly targeting measurement of the polarization of the cosmic microwave background (CMB). In this 18 month TRP programme the consortium are tasked with developing, manufacturing and experimentally verifying a prototype multichroic pixel which would be suitable for the large focal plane arrays which will be demanded to reach the required sensitivity of future CMB polarization missions. One major development was to have multichroic operation to potentially reduce the required focal plane size of a CMB mission. After research in the optimum telescope design and definition of requirements based on a stringent science case review, a number of compact focal plane architecture concepts were investigated before a pixel demonstrator consisting of a planar mesh lens feeding a backend Resonant Cold Electron Bolometer RCEB for filtering and detection of the dual frequency signal was planned for manufacture and test. In this demonstrator the frequencies of the channels was chosen to be 75 and 105 GHz in the w band close to the peak CMB signal. In the next year the prototype breadboards will be developed to test the beams produced by the manufactured flat lenses fed by a variety of antenna configurations and the spectral response of the RCEBs will also be verified.

  16. Depth of cure of bulk-fill flowable composite resins.

    Science.gov (United States)

    Pedalino, Inaam; Hartup, Grant R; Vandewalle, Kraig S

    2015-01-01

    In recent years, manufacturers have introduced flowable composite resins that reportedly can be placed in increments of 4 mm or greater. The purpose of this study was to evaluate the depth of cure of bulk-fill flowable composite resins (SureFil SDR Flow, Grandio Flow, and Venus Bulk Fill) and a conventional flowable composite resin (Revolution Formula 2). Depth of cure was measured in terms of bottom-maximum Knoop hardness number (KHN) ratios and the International Organization for Standardization (ISO) 4049 scrape technique. Shades A2 and A3 of SureFil SDR Flow, Grandio Flow, and Revolution Formula 2 were tested. Venus Bulk Fill was tested in its only available shade (universal). Specimens in thicknesses of 2, 3, 4, 5, and 6 mm were polymerized for 20 or 40 seconds, and a hardness tester was used to determine the hardness ratios for each shade at each thickness. For the scraping technique, after specimens were exposed to the curing light, unpolymerized composite resin was removed with a plastic instrument, the polymerized composite was measured, and the length was divided by 2 per ISO guidelines. According to the KHN ratios and the scrape test, Venus Bulk Fill predictably exceeded the manufacturer's claim of a 4-mm depth of cure at both 20 and 40 seconds of curing time. The overall results for depth of cure showed that Venus Bulk Fill ≥ SureFil SDR Flow ≥ Grandio Flow ≥ Revolution Formula 2.

  17. Methods for studying the focal spot size and resolution of diagnostic X-ray tubes

    International Nuclear Information System (INIS)

    Fairbanks, R.; Doust, C.

    1979-01-01

    Attention is given to techniques appropriate for use in the clinical situation. The focal spot size is critical to geometric unsharpness and hence the quality of the finished radiograph, but pinhole imaging of the focal spot is extremely difficult in clinical practice. The resolution of an X-ray tube, although a function of focal spot size, is of more importance in radiography. A comparison is made of various resolution grids suitable for quality control use in X-ray departments. (U.K.)

  18. HIGH PERFORMANCE PIAA CORONAGRAPHY WITH COMPLEX AMPLITUDE FOCAL PLANE MASKS

    International Nuclear Information System (INIS)

    Guyon, Olivier; Martinache, Frantz; Belikov, Ruslan; Soummer, Remi

    2010-01-01

    We describe a coronagraph approach where the performance of a Phase-Induced Amplitude Apodization (PIAA) coronagraph is improved by using a partially transmissive phase-shifting focal plane mask and a Lyot stop. This approach combines the low inner working angle offered by phase mask coronagraphy, the full throughput and uncompromized angular resolution of the PIAA approach, and the design flexibility of Apodized Pupil Lyot Coronagraph. A PIAA complex mask coronagraph (PIAACMC) is fully described by the focal plane mask size, or, equivalently, its complex transmission which ranges from 0 (opaque) to -1 (phase shifting). For all values of the transmission, the PIAACMC theoretically offers full on-axis extinction and 100% throughput at large angular separations. With a pure phase focal plane mask (complex transmission = -1), the PIAACMC offers 50% throughput at 0.64 λ/D while providing total extinction of an on-axis point source. This performance is very close to the 'fundamental performance limit' of coronagraphy derived from first principles. For very high contrast level, imaging performance with PIAACMC is in practice limited by the angular size of the on-axis target (usually a star). We show that this fundamental limitation must be taken into account when choosing the optimal value of the focal plane mask size in the PIAACMC design. We show that the PIAACMC enables visible imaging of Jupiter-like planets at ∼1.2 λ/D from the host star, and can therefore offer almost three times more targets than a PIAA coronagraph optimized for this type of observation. We find that for visible imaging of Earth-like planets, the PIAACMC gain over a PIAA is probably much smaller, as coronagraphic performance is then strongly constrained by stellar angular size. For observations at 'low' contrast (below ∼ 10 8 ), the PIAACMC offers significant performance enhancement over PIAA. This is especially relevant for ground-based high contrast imaging systems in the near-IR, where

  19. Predicting Maximum Lake Depth from Surrounding Topography

    Science.gov (United States)

    Lake volume aids understanding of the physical and ecological dynamics of lakes, yet is often not readily available. The data needed to calculate lake volume (i.e. bathymetry) are usually only collected on a lake by lake basis and are difficult to obtain across broad regions. ...

  20. The Simbol-X Focal Plane

    Science.gov (United States)

    Laurent, P.

    2009-05-01

    The Simbol-X focal plane is designed to detect photons focused by the mirror in the 0.5 to 100 keV energy band. Composed of two detectors, it will measure the position, energy, and arrival time of each incoming X-ray. On top of it will be a collimator to shield all photons not coming from the mirror field of view. The whole system is surrounded by an active and passive shielding in order to ensure the required very low background.

  1. Surveillance following Focal Therapy interventions Seguimiento tras el tratamiento focal en el cáncer de próstata localizado

    NARCIS (Netherlands)

    Postema, A. W.; Catellani, M.; Scheltema, M. J. V.; van den Bos, W.; de la Rosette, J. J. M. C. H.

    2016-01-01

    Focal therapy (FT) is a tissuesparing treatment paradigm for localized prostate cancer (PCa) with the potential to improve functional outcomes while maintaining oncologic safety. This paper aims to provide an overview of important considerations and practical recommendations relating to the

  2. Effects of cue focality on the neural mechanisms of prospective memory: A meta-analysis of neuroimaging studies.

    Science.gov (United States)

    Cona, Giorgia; Bisiacchi, Patrizia Silvia; Sartori, Giuseppe; Scarpazza, Cristina

    2016-05-17

    Remembering to execute pre-defined intentions at the appropriate time in the future is typically referred to as Prospective Memory (PM). Studies of PM showed that distinct cognitive processes underlie the execution of delayed intentions depending on whether the cue associated with such intentions is focal to ongoing activity processing or not (i.e., cue focality). The present activation likelihood estimation (ALE) meta-analysis revealed several differences in brain activity as a function of focality of the PM cue. The retrieval of intention is supported mainly by left anterior prefrontal cortex (Brodmann Area, BA 10) in nonfocal tasks, and by cerebellum and ventral parietal regions in focal tasks. Furthermore, the precuneus showed increased activation during the maintenance phase of intentions compared to the retrieval phase in nonfocal tasks, whereas the inferior parietal lobule showed increased activation during the retrieval of intention compared to maintenance phase in the focal tasks. Finally, the retrieval of intention relies more on the activity in anterior cingulate cortex for nonfocal tasks, and on posterior cingulate cortex for focal tasks. Such focality-related pattern of activations suggests that prospective remembering is mediated mainly by top-down and stimulus-independent processes in nonfocal tasks, whereas by more automatic, bottom-up, processes in focal tasks.

  3. Curved planar reconstruction of MR images in focal cortical dysplasia of the brain

    International Nuclear Information System (INIS)

    Chung, Gyung Ho; Lee, Sang Yong; Kim, Chong So; Kim, Young Kon; Lee, Young Hwan; Jeong, Su Hyun

    2002-01-01

    To describe curved planar reconstruction imaging (CPR) and determine its usefulness in the evaluation of focal cortical dysplasia of the brain. In 17 cases of focal cortical dysplasia (cortical dysplasia (n=9), schizencephaly (n=5), and heterotopia (n=3), CPR images were created using a multiplanar reconstruction program and imaging data obtained during T1 magnetization prepared rapid acquisition gradient-echo MR imaging. We assessed the precise configuration of abnormalities and their relation to adjacent gyri and sulci. CPRI showed the brain cortex as a 2D panoramic image, demonstrating the precise configurations and locations of dysplasia-associated abnormalities and their relation to adjacent gyri and sulci, and the precise shape of the gray-white matter interface. CPRI can provide important radiological information about the extension and configuration of focal cortical dysplasia, and its relation to neighboring cortical structures. We believe that CPRI should form an essential part of the routine investigation os suspected cases of focal cortical dysplasia

  4. Comparison of different methods for determining the size of a focal spot of microfocus X-ray tubes

    International Nuclear Information System (INIS)

    Salamon, M.; Hanke, R.; Krueger, P.; Sukowski, F.; Uhlmann, N.; Voland, V.

    2008-01-01

    The EN 12543-5 describes a method for determining the focal spot size of microfocus X-ray tubes up to a minimum spot size of 5 μm. The wide application of X-ray tubes with even smaller focal spot sizes in computed tomography and radioscopy applications requires the evaluation of existing methods for focal spot sizes below 5 μm. In addition, new methods and conditions for determining submicron focal spot sizes have to be developed. For the evaluation and extension of the present methods to smaller focal spot sizes, different procedures in comparison with the existing EN 12543-5 were analyzed and applied, and the results are presented

  5. Refractive neutron lens

    International Nuclear Information System (INIS)

    Petrov, P.V.; Kolchevsky, N.N.

    2013-01-01

    Model of the refractive neutron lens is proposed. System of N lenses acts as one thin lens with a complex refraction index n*. The maximum number N max of individual lenses for 'thick' neutron lens is calculated. Refractive neutron lens properties (resolution, focal depth) as function of resolution factor F 0 =ρbc/μ and depth of field factor dF 0 =λF 0 =λρbc/μ are calculated. It is shown that micro resolution of the refractive neutron optics is far from the wavelength in size and its open possibilities for progress in refractive neutron optics. (authors)

  6. What Can Radiocarbon Depth Profiles Tell Us About The LGM Circulation?

    Science.gov (United States)

    Burke, A.; Stewart, A.; Adkins, J. F.; Ferrari, R. M.; Thompson, A. F.; Jansen, M. F.

    2014-12-01

    Published reconstructions of radiocarbon in the Atlantic sector of the Southern Ocean indicate that there is a mid-depth maximum in radiocarbon age during the last glacial maximum (LGM). This is in contrast to the modern ocean where intense mixing between water masses along shared density surfaces (isopycnals) results in a relatively homogenous radiocarbon profile. A recent study (Ferrari et al. 2014) suggested that the extended Antarctic sea ice cover during the LGM necessitated a shallower boundary between the upper and lower branches of the meridional overturning circulation (MOC). This shoaled boundary lay above major topographic features and their associated strong diapycnal mixing, which isolated dense southern-sourced water in the lower branch of the overturning circulation. This isolation would have allowed radiocarbon to decay, and thus provides a possible explanation for the mid-depth radiocarbon age bulge. We test this hypothesis using an idealized, 2D, residual-mean dynamical model of the global overturning circulation. Concentration distributions of a decaying tracer that is advected by the simulated overturning are compared to published radiocarbon data. We test the sensitivity of the mid-depth radiocarbon age to changes in sea ice extent, wind strength, and isopycnal and diapycnal diffusion. The mid-depth radiocarbon age bulge is most likely caused by the different circulation geometry, associated with increased sea ice extent. In particular, with an LGM-like sea ice extent the upper and lower branches of the MOC no longer share isopycnals, so radiocarbon-rich northern-sourced water is no longer mixed rapidly into the southern-sourced water. However, this process alone cannot explain the magnitude of the glacial radiocarbon anomalies; additional isolation (e.g. from reduced air-sea gas exchange associated with the increased sea ice) is required. Ferrari, R., M. F. Jansen, J. F. Adkins, A. Burke, A. L. Stewart, and A. F. Thompson (2014), Antarctic sea

  7. Seizure ending signs in patients with dyscognitive focal seizures.

    Science.gov (United States)

    Gavvala, Jay R; Gerard, Elizabeth E; Macken, Mícheál; Schuele, Stephan U

    2015-09-01

    Signs indicating the end of a focal seizure with loss of awareness and/or responsiveness but without progression to focal or generalized motor symptoms are poorly defined and can be difficult to determine. Not recognizing the transition from ictal to postictal behaviour can affect seizure reporting accuracy by family members and may lead to delayed or a lack of examination during EEG monitoring, erroneous seizure localization and inadequate medical intervention for prolonged seizure duration. Our epilepsy monitoring unit database was searched for focal seizures without secondary generalization for the period from 2007 to 2011. The first focal seizure in a patient with loss of awareness and/or responsiveness and/or behavioural arrest, with or without automatisms, was included. Seizures without objective symptoms or inadequate video-EEG quality were excluded. A total of 67 patients were included, with an average age of 41.7 years. Thirty-six of the patients had seizures from the left hemisphere and 29 from the right. All patients showed an abrupt change in motor activity and resumed contact with the environment as a sign of clinical seizure ending. Specific ending signs (nose wiping, coughing, sighing, throat clearing, or laughter) were seen in 23 of 47 of temporal lobe seizures and 7 of 20 extra-temporal seizures. Seizure ending signs are often subtle and the most common finding is a sudden change in motor activity and resumption of contact with the environment. More distinct signs, such as nose wiping, coughing or throat clearing, are not specific to temporal lobe onset. A higher proportion of seizures during sleep went unexamined, compared to those during wakefulness. This demonstrates that seizure semiology can be very subtle and arousals from sleep during monitoring should alert staff. Patient accounts of seizure frequency appear to be unreliable and witness reports need to be taken into account. [Published with video sequences].

  8. How to diagnose and treat focal therapy failure and recurrence?

    Science.gov (United States)

    Barret, Eric; Harvey-Bryan, Kadi-Ann; Sanchez-Salas, Rafael; Rozet, Francois; Galiano, Marc; Cathelineau, Xavier

    2014-05-01

    Focal therapy presents an alternative option for disease-targeted therapy while preserving erectile and urinary function without compromising oncological outcome. Such treatment, which preserves normal prostate parenchyma, presents a clinical challenge to the urologist, as typical disease surveillance parameters are not as reliable in post-ablation follow-up. We propose an integrated approach to post-ablation surveillance to identify treatment failure as well as recurrence. Post-ablation prostate-specific antigen kinetics, imaging based on multiparametric MRI and control biopsies are the tools currently used to follow patients after focal therapy. Good treatment response is indicated by a negative control biopsy, absence of persistent lesion on post-treatment imaging and a reduction in prostate-specific antigen of at least 50%. When histological evidence of therapeutic failure or recurrence is present, different options of management may be proposed to the patient including active surveillance, focal salvage therapy or radical salvage treatment, depending on the characteristics of the lesion found. A recommended post-ablation surveillance protocol is presented as well as a discussion of management strategies based on the data currently available.

  9. Detection and Characterization of Focal Hepatic lesions using Magnetic resonance Imaging

    International Nuclear Information System (INIS)

    Pulgarin, Luis G; Delgado, Jorge Andres; Toro Nancy

    2008-01-01

    A retrospective one year study was performed from June 2006 to June 2007. A total of ten focal liver lesions in 60 patients were examined, describing their magnetic resonance (MR) characteristics, using T1, T2 and dynamic Gd-enhanced T1 weighted sequences with and without fat suppression. Lesions were classified into benign or malignant tumors and a diagnosis was proposed. Specific diagnoses such as simple cyst, abscess, hemangioma, focal nodular hyperplasia, hepatocellular carcinoma, and cholangiocarcinoma were reported.

  10. Variation in Depth Dose Data between Open and Wedge Fields for 6 MV X-Rays

    International Nuclear Information System (INIS)

    U, Hong; Ryu, M. S. Samuel; Park, In Kyu

    1989-01-01

    Central axis depth dose data for 6 MV X-rays, including tissue maximum ratios, were measured for wedge fields according to Tatcher equation. In wedge fields, the differences in magnitude which increased with depth, field size, and wedge thickness increased when compared with the corresponding open field data. However, phantom scatter correction factors for wedge fields differed less that 1% from the corresponding open field factors. The differences in central axis percent depth dose between two types of fields indicated beam hardening by the wedge filter. The deviation of percent depth doses and scatter correction factors between the effective wedge field and the nominal wedge field at same angle was negligible. The differences were less than 3.26% between the nominal or effective wedge fields and the open fields for percent depth doses to the depth 7cm in 6cm x 6cm field. For larger (10cm x 10cm) field size, however, the deviation of percent depth doses between the nominal or effective wedge fields and the open fields were greater-dosimetric errors were 3.56% at depth 7cm and nearly 5.30% at 12cm. We suggest that the percent depth doses of individual wedge and wedge transmission factors should be considered for the dose calculation or monitor setting in the treatment of deep seated tumor

  11. Minimum critical crack depths in pressure vessels guidelines for nondestructive testing

    International Nuclear Information System (INIS)

    Crossley, M.R.; Townley, C.H.A.

    1983-09-01

    Estimates of the minimum critical depths which can be expected in high quality vessels designed to certain British and American Code rules are given. A simple means of allowing for fatigue crack growth in service is included. The data which are presented can be used to decide what sensitivity and what reporting levels should be employed during an ultrasonic inspection of a pressure vessel. It is emphasised that the minimum crack depths are those which would be relevant to a vessel in which the material is stressed to its maximum permitted value during operation. Stresses may, in practice, be significantly less than this. Less restrictive inspection standards may be established, if it were considered worthwhile to carry out a detailed stress analysis of the particular vessel under examination. (author)

  12. A case report: Familial glucocorticoid deficiency associated with familial focal segmental glomerulosclerosis

    Directory of Open Access Journals (Sweden)

    Ram Nanik

    2012-12-01

    Full Text Available Abstract Background Familial glucocorticoid deficiency (FGD is a rare autosomal recessive disorder characterized by isolated glucocorticoid deficiency in the presence of normal plasma renin and aldosterone level. Focal segmental glomerulosclerosis (FSGS is a form of glomerular disease associated with proteinuria and nephritic syndrome. This is the first case of familial glucocorticoid deficiency associated with familial focal segmental glomerulosclerosis. Case presentation An eight month old boy presented with increased genital pigmentation. Initial investigation revealed that he was glucocorticoid deficient and was started on hydrocortisone and fludrocortisone with a diagnosis of primary adrenal insufficiency. Later fludrocortisone was withdrawn and he was diagnosed to have isolated glucocorticoid deficiency. He later developed focal segmental glomerulosclerosis for which he underwent renal transplantation at the age of five years. Now at the age of twelve years, this boy is doing well on hydrocortisone treatment. His two siblings and a first degree cousin also had isolated glucocorticoid deficiency. One of the above two siblings died due to renal failure secondary to focal segmental glomerulosclerosis. Conclusion Patients with familial glucocorticoid deficiency should be carefully followed for development of features of nephrotic syndrome.

  13. Comparison of different approaches to the numerical calculation of the LMJ focal

    Directory of Open Access Journals (Sweden)

    Bourgeade A.

    2013-11-01

    Full Text Available The beam smoothing in the focal plane of high power lasers is of particular importance to laser-plasma interaction studies in order to minimize plasma parametric and hydrodynamic instabilities on the target. Here we investigate the focal spot structure in different geometrical configurations where standard paraxial hypotheses are no longer verified. We present numerical studies in the cases of single flat top square beam, LMJ quadruplet and complete ring of quads with large azimuth angle. Different calculations are made with Fresnel diffraction propagation model in the paraxial approximation and full vector Maxwell's equations. The first model is based on Fourier transform from near to far field method. The second model uses first spherical wave decomposition in plane waves with Fourier transform and propagates them to the focal spot. These two different approaches are compared with Miró [1] modeling results using paraxial or Feit and Fleck options. The methods presented here are generic for focal spot calculations. They can be used for other complex geometric configurations and various smoothing techniques. The results will be used as boundary conditions in plasma interaction computations.

  14. Contact irritant responses of Aedes aegypti Using sublethal concentration and focal application of pyrethroid chemicals.

    Science.gov (United States)

    Manda, Hortance; Shah, Pankhil; Polsomboon, Suppaluck; Chareonviriyaphap, Theeraphap; Castro-Llanos, Fanny; Morrison, Amy; Burrus, Roxanne G; Grieco, John P; Achee, Nicole L

    2013-01-01

    Previous studies have demonstrated contact irritant and spatial repellent behaviors in Aedes aegypti following exposure to sublethal concentrations of chemicals. These sublethal actions are currently being evaluated in the development of a push-pull strategy for Ae. aegypti control. This study reports on mosquito escape responses after exposure to candidate chemicals for a contact irritant focused push-pull strategy using varying concentrations and focal application. Contact irritancy (escape) behavior, knockdown and 24 hour mortality rates were quantified in populations of female Ae. aegypti under laboratory conditions and validated in the field (Thailand and Peru) using experimental huts. Evaluations were conducted using varying concentrations and treatment surface area coverage (SAC) of three pyrethroid insecticides: alphacypermethrin, lambacyhalothrin and deltamethrin. Under laboratory conditions, exposure of Ae. aegypti to alphacypermethrin using the standard field application rate (FAR) resulted in escape responses at 25% and 50% SAC that were comparable with escape responses at 100% SAC. Significant escape responses were also observed at time of exit (by four hours) and 40% increase in escape using ½FAR of alphacypermethrin at 75% SAC compared to a matched chemical-free control. In Peru, however, the maximum increase in Ae. aegypti escape from alphacypermethrin-treated huts was 11%. Results presented here suggest a potential role for sublethal and focal application of contact irritant chemicals in an Ae. aegypti push-pull strategy to reduce human-vector contact inside treated homes. However, the impact of an increase in escape response on dengue virus transmission is currently unknown and will depend on rate of biting on human hosts prior to house exiting.

  15. Technology for advanced focal plane arrays of HgCdTe and AIGaN

    CERN Document Server

    He, Li; Ni, Guoqiang

    2016-01-01

    This book introduces the basic framework of advanced focal plane technology based on the third-generation infrared focal plane concept. The essential concept, research advances, and future trends in advanced sensor arrays are comprehensively reviewed. Moreover, the book summarizes recent research advances in HgCdTe/AlGaN detectors for the infrared/ultraviolet waveband, with a particular focus on the numerical method of detector design, material epitaxial growth and processing, as well as Complementary Metal-Oxide-Semiconductor Transistor readout circuits. The book offers a unique resource for all graduate students and researchers interested in the technologies of focal plane arrays or electro-optical imaging sensors.

  16. [Focal hyperhidrosis.Quality of life, socioeconomic importance and use of internal medicinal therapy].

    Science.gov (United States)

    Rzany, B; Müller, C; Hund, M

    2012-06-01

    Focal hyperhidrosis can have a substantial influence on the professional, physical, emotional and social life of those affected. This becomes clear when the results of quality of life studies and Health Service Research studies are reviewed, e.g. affected patients were prepared to contribute additional money for treatment of hyperhidrosis. The systemic therapy of focal hyperhidrosis with oral anticholinergic agents is a quite economical treatment strategy. These products can be administered continuously or sporadically. However, only good clinical date for the continous treatment exists. Focal hyperhidrosis is a disease which requires our full attention. It should be discussed whether e.g. QoL questionnaires should be used routinelly.

  17. Focal nodular hyperplasia: imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Kehagias, D.; Moulopoulos, L.; Antoniou, A.; Hatziioannou, A.; Smyrniotis, V.; Trakadas, S.; Lahanis, S.; Vlahos, L. [Dept. of Radiology, University of Athens (Greece)

    2001-02-01

    Focal nodular hyperplasia is an uncommon benign hepatic tumor that continues to pose diagnostic dilemmas. Imaging techniques are of great value in diagnosis of this tumor. In this article we present the US, CT, MR imaging, scintigraphy, and angiography findings. The demonstration of a central vascular scar is very helpful. Although the radiologic features may be diagnostic, many atypical cases must be differentiated from other benign or malignant hepatic tumors. In these cases excisional biopsy and histopathologic examination are necessary to determine a definite diagnosis. (orig.)

  18. Focal nodular hyperplasia: imaging findings

    International Nuclear Information System (INIS)

    Kehagias, D.; Moulopoulos, L.; Antoniou, A.; Hatziioannou, A.; Smyrniotis, V.; Trakadas, S.; Lahanis, S.; Vlahos, L.

    2001-01-01

    Focal nodular hyperplasia is an uncommon benign hepatic tumor that continues to pose diagnostic dilemmas. Imaging techniques are of great value in diagnosis of this tumor. In this article we present the US, CT, MR imaging, scintigraphy, and angiography findings. The demonstration of a central vascular scar is very helpful. Although the radiologic features may be diagnostic, many atypical cases must be differentiated from other benign or malignant hepatic tumors. In these cases excisional biopsy and histopathologic examination are necessary to determine a definite diagnosis. (orig.)

  19. Accurate Depth of Radiofrequency-Induced Lesions in Renal Sympathetic Denervation Based on a Fine Histological Sectioning Approach in a Porcine Model.

    Science.gov (United States)

    Sakaoka, Atsushi; Terao, Hisako; Nakamura, Shintaro; Hagiwara, Hitomi; Furukawa, Toshihito; Matsumura, Kiyoshi; Sakakura, Kenichi

    2018-02-01

    Ablation lesion depth caused by radiofrequency-based renal denervation (RDN) was limited to radiofrequency-RDN cannot ablate a substantial percentage of renal sympathetic nerves. We aimed to define the true lesion depth achieved with radiofrequency-RDN using a fine sectioning method and to investigate biophysical parameters that could predict lesion depth. Radiofrequency was delivered to 87 sites in 14 renal arteries from 9 farm pigs at various ablation settings: 2, 4, 6, and 9 W for 60 seconds and 6 W for 120 seconds. Electric impedance and electrode temperature were recorded during ablation. At 7 days, 2470 histological sections were obtained from the treated arteries. Maximum lesion depth increased at 2 to 6 W, peaking at 6.53 (95% confidence interval, 4.27-8.78) mm under the 6 W/60 s condition. It was not augmented by greater power (9 W) or longer duration (120 seconds). There were statistically significant tendencies at 6 and 9 W, with higher injury scores in the media, nerves, arterioles, and fat. Maximum lesion depth was positively correlated with impedance reduction and peak electrode temperature (Pearson correlation coefficients were 0.59 and 0.53, respectively). Lesion depth was 6.5 mm for radiofrequency-RDN at 6 W/60 s. The impedance reduction and peak electrode temperature during ablation were closely associated with lesion depth. Hence, these biophysical parameters could provide prompt feedback during radiofrequency-RDN procedures in the clinical setting. © 2018 The Authors.

  20. Influence of the crustal and subcrustal Vrancea seismic sources on Cernavoda nuclear power plant site

    International Nuclear Information System (INIS)

    Marmureanu, Gheorghe; Popescu, Emilia; Mircea Radulian

    2002-01-01

    The basis of the seismic hazard assessment in different geographical regions with dense-populated areas and strategic objectives (dams, nuclear power plants, etc.) is the study of seismicity of the seismogenic sources which affect these sites. The purpose of this paper is to provide a complete set of information relative to the Vrancea seismic source (in the crust and the intermediate depth domains) that is fundamental for the seismic hazard evaluation at Cernavoda nuclear power plant site. The analysis that we propose has to deal with the following items: (1) geometrical definition of the seismic sources; (2) setting the earthquake catalog associated to each seismic source; (3) estimation of the maximum possible magnitude; (4) estimation of the frequency - magnitude relationship; (5) computation of the distribution function for focal distance; (6) correlation between focal depth and magnitude; (7) attenuation law. We discuss also the implications of the model parameters on the seismic hazard level. (authors)

  1. Infrared detectors and focal plane arrays; Proceedings of the Meeting, Orlando, FL, Apr. 18, 19, 1990

    Science.gov (United States)

    Dereniak, Eustace L.; Sampson, Robert E.

    1990-09-01

    The papers contained in this volume provide an overview of recent advances and the current state of developments in the field of infrared detectors and focal plane arrays. Topics discussed include nickel silicide Schottky-barrier detectors for short-wavelength infrared applications; high performance PtSi linear and focal plane arrays; and multispectral band Schottky-barrier IRSSD for remote-sensing applications. Papers are also presented on the performance of an Insi hybrid focal array; characterization of IR focal plane test stations; GaAs CCD readout for engineered bandgap detectors; and fire detection system for aircraft cargo bays.

  2. Incidental Detection of Temporary Focal FDG Retention in the Spleen

    Energy Technology Data Exchange (ETDEWEB)

    Park, Youn Joon; Lee, Jai Hyuen; Jee, Keum Nahn; Namgung, Hwan [Dankook Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-06-15

    F 18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) is a valuable tool in discriminating malignancy from benign lesion. But because various false positive results reduce the diagnostic specificity, nuclear medicine physicians should be familiar with possible false positive cases. Although many cases of high FDG uptake mimicking malignancy have been reported, temporary intense focal FDG uptake of normal spleen has not been reported previously. We report herein a phenomenon of temporary intense focal FDG uptake of normal spleen without evidence of metastasis in a 46 year old woman with a history of anal cancer.

  3. Interacting Effects Induced by Two Neighboring Pits Considering Relative Position Parameters and Pit Depth

    Directory of Open Access Journals (Sweden)

    Yongfang Huang

    2017-04-01

    Full Text Available For pre-corroded aluminum alloy 7075-T6, the interacting effects of two neighboring pits on the stress concentration are comprehensively analyzed by considering various relative position parameters (inclination angle θ and dimensionless spacing parameter λ and pit depth (d with the finite element method. According to the severity of the stress concentration, the critical corrosion regions, bearing high susceptibility to fatigue damage, are determined for intersecting and adjacent pits, respectively. A straightforward approach is accordingly proposed to conservatively estimate the combined stress concentration factor induced by two neighboring pits, and a concrete application example is presented. It is found that for intersecting pits, the normalized stress concentration factor Ktnor increases with the increase of θ and λ and always reaches its maximum at θ = 90°, yet for adjacent pits, Ktnor decreases with the increase of λ and the maximum value appears at a slight asymmetric location. The simulations reveal that Ktnor follows a linear and an exponential relationship with the dimensionless depth parameter Rd for intersecting and adjacent cases, respectively.

  4. Impact of variations in fatty liver on sonographic detection of focal hepatic lesions originally identified by CT

    OpenAIRE

    Wu, Size; Tu, Rong; Nan, Ruixia; Liu, Guangqing; Cui, Xiaojing; Liang, Xian

    2015-01-01

    Purpose: The aim of this study was to investigate the influence of variations in fatty liver on the ultrasonographic detection of focal liver lesions. Methods: A total of 229 patients with varying degrees of fatty liver and focal liver lesions and 200 patients with focal liver lesions but no fatty liver were randomly selected for inclusion in groups I and II, respectively. Findings of focal liver lesions identified on computed tomography were taken as the reference, and findings on ultrasonog...

  5. Focal spot motion of linear accelerators and its effect on portal image analysis

    NARCIS (Netherlands)

    Sonke, Jan-Jakob; Brand, Bob; van Herk, Marcel

    2003-01-01

    The focal spot of a linear accelerator is often considered to have a fully stable position. In practice, however, the beam control loop of a linear accelerator needs to stabilize after the beam is turned on. As a result, some motion of the focal spot might occur during the start-up phase of

  6. Syndecan-4 and focal adhesion function

    DEFF Research Database (Denmark)

    Woods, A; Couchman, J R

    2001-01-01

    Two groups have now reported the viability of mice that lack syndecan-4. These mice have wound healing/angiogenesis problems, and fibroblasts from these animals differ in adhesion and migration from normal. This is consistent with recent in vitro data indicating a need for signaling via syndecan-4...... for focal adhesion formation, and reports that overexpression of proteins that bind syndecan-4 can modify cell adhesion and migration....

  7. Focal Mechanism of Semi-Volcanic Deep Low-Frequency Earthquakes in Eastern Shimane

    Science.gov (United States)

    Aso, N.; Ohta, K.; Ide, S.

    2012-12-01

    Many deep low-frequency earthquakes (LFEs) occur near the island arc Mohorovicic discontinuities and far from both active volcanoes and plate boundaries. They are quite similar to volcanic LFEs beneath active volcanoes, which infers some fluid movement in the source region, and we regard them as "semi-volcanic" LFEs [Aso et al., 2011; 2012 (submitted)]. Several previous studies determined the focal mechanisms of volcanic and semi-volcanic LFEs using a small portion of information of the waveforms. Although the estimated focal mechanisms are various, they may not necessary support the variety of the actual physical process, owing to the large determination error [e.g., Nishidomi and Takeo, 1996; Ohmi and Obara, 2002; Nakamichi et al., 2003]. Here we determine the focal mechanisms by waveform inversion for LFEs in eastern Shimane in western Japan, where many LFEs occurred in a quiet region. The locations are also close to the fault plane of the 2000 western Tottori earthquake of Mw6.6, and right beneath Yokota volcano, which is a Quaternary volcanic cluster. We estimated the focal mechanisms of semi-volcanic LFEs in eastern Shimane by moment tensor inversion. The data are velocity seismograms at five stations of Hi-net near the epicenters. For each seismogram, we extracted a 1.5-second time window beginning from 0.2 seconds before the arrivals of either P-wave in a vertical component or S-wave in a horizontal component. The arrival time of each phase is picked manually first, and then corrected to minimize the variance between observed and synthetic waveforms. The local site amplification is estimated using far-field body waves from deep intraslab earthquakes, and collected for each seismogram. The synthetic waveforms were calculated using the discrete wavenumber integration method developed by Takeo [1985] for a horizontally layered structure. For 38 LFEs, which are equal to or larger than M1.2 (JMA magnitude) and recorded at all five stations, the focal mechanisms

  8. Differential diagnosis of focal pancreatitis and pancreatic cancer

    NARCIS (Netherlands)

    van Gulik, T. M.; Moojen, T. M.; van Geenen, R.; Rauws, E. A.; Obertop, H.; Gouma, D. J.

    1999-01-01

    The differentiation of focal, chronic pancreatitis (CP) and pancreatic cancer (PAC) poses a diagnostic dilemma. Both conditions may present with the same symptoms and signs. The complexity of differential diagnosis is enhanced because PAC is frequently associated with secondary inflammatory changes

  9. Small cardiac lesions: fibrosis of papillary muscles and focal cardiac myocytolysis

    Energy Technology Data Exchange (ETDEWEB)

    Steer, A [Hijiyanna Park, Hiroshima JP; Nakashima, N; Kawashima, T; Lee, K K; Danzig, M D; Robertson, T L; Dock, D S

    1977-11-01

    Three types of small cardiac lesions were described and illustrated: (1) focal type of papillary muscle fibrosis, evidently a healed infarct of the papillary muscle present in 13% of the autopsies, is a histologically characteristic lesion associated with coronary artery disease and healed myocardial infarction; (2) diffuse type of papillary muscle fibrosis, probably an aging change present in almost half of the autopsies, is associated with sclerosis of the arteries in the papillary muscle, is identifiable histologically; and apparently is not associated with any cardiac abnormality; and (3) focal cardiac myocytolysis, a unique histologic lesion, usually multifocal without predilection for any area of the heart, is associated with ischemic heart disease, death due to cancer complicated by non-bacterial thrombotic endocarditis and microthrombi in small cardiac arteries as well as with other diseases. Differentiation of the 2 types of papillary muscle fibrosis is important in the study of papillary muscle and mitral valve dysfunction. Focal cardiac myocytolysis may contribute to the fatal extension of myocardial infarcts.

  10. Small cardiac lesions: fibrosis of papillary muscles and focal cardiac myocytolysis

    Energy Technology Data Exchange (ETDEWEB)

    Steer, A; Nakashima, T; Kawashima, T; Lee, K K; Danzig, M D; Robertson, T L; Dock, D S

    1977-11-01

    Three types of small cardiac lesions were described and illustrated: (1) focal type of papillary muscle fibrosis, evidently a healed infarct of the papillary muscle present in 13% of the autopsies, is a histologically characteristic lesion associated with coronary artery disease and healed myocardial infarction, (2) diffuse type of papillary muscle fibrosis, probably an aging change present in almost half of the autopsies, is associated with sclerosis of the arteries in the papillary muscle, is identifiable histologically, and apparently is not associated with any cardiac abnormality, and (3) focal cardiac myochtolysis, a unique histologic lesion, usually multifocal without predilection for any area of the heart, is associated with ischemic heart disease, death due to cancer complicated by nonbacterial thrombotic endocarditis and microthrombi in small cardiac arteries as well as with other diseases. Differentiation of the 2 types of papillary muscle fibrosis is important in the study of papillary muscle and mitral valve dysfunction. Focal cardiac myocytolysis may contribute to the fatal extension of myocardial infarcts.

  11. Infrared MUSIC from Z technology focal planes

    International Nuclear Information System (INIS)

    Waters, C.R.; Sommese, A.; Johnston, D.; Landau, H.

    1989-01-01

    Presented is the Multiple Signal Classification (MUSIC) algorithm which uses the high frequency differences in sensed time signals to discriminate, count, and accurately locate closely spaced targets. Z technology focal planes allow the implementation of this algorithm and the trade-off between finer spatial resolution systems and systems with coarser resolution but higher sampling rates

  12. SNAP Satellite Focal Plane Development

    International Nuclear Information System (INIS)

    Bebek, C.; Akerlof, C.; Aldering, G.; Amanullah, R.; Astier, P.; Baltay, C.; Barrelet, E.; Basa, S.; Bercovitz, J.; Bergstrom, L.; Berstein, G.P.; Bester, M.; Bohlin, R.; Bonissent, A.; Bower, C.; Campbell, M.; Carithers, W.; Commins, E.; Day, C.; Deustua, S.; DiGennaro, R.; Ealet, A.; Ellis, R.; Emmett, W.; Eriksson, M.; Fouchez, D.; Fruchter, A.; Genat, J-F.; Goldhaber, G.; Goobar, A.; Groom, D.; Heetderks, H.; Holland, S.; Huterer, D.; Johnson, W.; Kadel, R.; Karcher, A.; Kim, A.; Kolbe, W.; Lafever, R.; Lamoureaux, J.; Lampton, M.; Lefevre, O.; Levi, M.; Levin, D.; Linder, E.; Loken, S.; Malina, R.; Mazure, A.; McKay, T.; McKee, S.; Miquel, R.; Morgan, N.; Mortsell, E.; Mostek, N.; Mufson, S.; Musser, J.; Roe, N.; Nugent, P.; Oluseyi, H.; Pain, R.; Palaio, N.; Pankow, D.; Perlmutter, S.; Prieto, E.; Rabinowitz, D.; Refregier, A.; Rhodes, J.; Schubnell, M.; Sholl, M.; Smadja, G.; Smith, R.; Smoot, G.; Snyder, J.; Spadafora, A.; Szymkowiak, A.; Tarle, G.; Taylor, K.; Tilquin, A.; Tomasch, A.; Vincent, D.; von der Lippe, H.; Walder, J-P.; Wang, G.

    2003-01-01

    The proposed SuperNova/Acceleration Probe (SNAP) mission will have a two-meter class telescope delivering diffraction-limited images to an instrumented 0.7 square degree field in the visible and near-infrared wavelength regime. The requirements for the instrument suite and the present configuration of the focal plane concept are presented. A two year R and D phase, largely supported by the Department of Energy, is just beginning. We describe the development activities that are taking place to advance our preparedness for mission proposal in the areas of detectors and electronics

  13. An Exploration of the Needling Depth in Acupuncture: The Safe Needling Depth and the Needling Depth of Clinical Efficacy

    Directory of Open Access Journals (Sweden)

    Jaung-Geng Lin

    2013-01-01

    Full Text Available Objective. To explore the existing scientific information regarding safe needling depth of acupuncture points and the needling depth of clinical efficacy. Methods. We searched the PubMed, EMBASE, Cochrane, Allied and Complementary Medicine (AMED, The National Center for Complementary and Alternative Medicine (NCCAM, and China National Knowledge Infrastructure (CNKI databases to identify relevant monographs and related references from 1991 to 2013. Chinese journals and theses/dissertations were hand searched. Results. 47 studies were recruited and divided into 6 groups by measuring tools, that is, MRI, in vivo evaluation, CT, ultrasound, dissected specimen of cadavers, and another group with clinical efficacy. Each research was analyzed for study design, definition of safe depth, and factors that would affect the measured depths. Depths of clinical efficacy were discussed from the perspective of de-qi and other clinical observations. Conclusions. Great inconsistency in depth of each point measured from different subject groups and tools exists. The definition of safe depth should be established through standardization. There is also lack of researches to compare the clinical efficacy. A well-designed clinical trial selecting proper measuring tools to decide the actual and advisable needling depth for each point, to avoid adverse effects or complications and promote optimal clinical efficacy, is a top priority.

  14. Laparoscopic Partial Hepatectomy of Focal Nodular Hyperplasia

    Directory of Open Access Journals (Sweden)

    Mayu Sakata

    2012-11-01

    Full Text Available Focal nodular hyperplasia is a benign liver lesion incidentally discovered with increasing frequency because of the proliferation of imaging studies. Radiographic characterization can diagnose this pathologic lesion and nonoperative therapy is the standard of care. However, surgical resection may be required for diagnostic reasons or symptomatic patients. Depending on the anatomic location of the lesion, biopsy and/or resection can be performed laparoscopically. We herein report the case of a 26-year-old Japanese woman with a hepatic tumor who required a medical examination. Her medical history was negative for alcohol abuse, oral contraceptive administration and trauma. Clinical examination showed no significant symptoms. Ultrasonography, computed tomography and magnetic resonance imaging showed a mass located in the left lateral segment of the liver with a diameter of about 40 mm. It was difficult to diagnose the tumor definitively from these imaging studies, so we performed laparoscopic partial hepatectomy with successive firing of endoscopic staplers. The histopathological diagnosis was focal nodular hyperplasia. Surgical procedures and postoperative course were uneventful and the patient was discharged from the hospital on postoperative day 5.

  15. Ultrasound elastographic techniques in focal liver lesions.

    Science.gov (United States)

    Conti, Clara Benedetta; Cavalcoli, Federica; Fraquelli, Mirella; Conte, Dario; Massironi, Sara

    2016-03-07

    Elastographic techniques are new ultrasound-based imaging techniques developed to estimate tissue deformability/stiffness. Several ultrasound elastographic approaches have been developed, such as static elastography, transient elastography and acoustic radiation force imaging methods, which include point shear wave and shear wave imaging elastography. The application of these methods in clinical practice aims at estimating the mechanical tissues properties. One of the main settings for the application of these tools has been liver stiffness assessment in chronic liver disease, which has been studied mainly using transient elastography. Another field of application for these techniques is the assessment of focal lesions, detected by ultrasound in organs such as pancreas, prostate, breast, thyroid, lymph nodes. Considering the frequency and importance of the detection of focal liver lesions through routine ultrasound, some studies have also aimed to assess the role that elestography can play in studying the stiffness of different types of liver lesions, in order to predict their nature and thus offer valuable non-invasive methods for the diagnosis of liver masses.

  16. Estimation of calcaneal loading during standing from human footprint depths using 3D scanner

    Science.gov (United States)

    Wibowo, Dwi Basuki; Haryadi, Gunawan Dwi; Widodo, Achmad; Rahayu, Sri Puji

    2017-01-01

    This research studies the relationship between footprint depths and load in the calcaneal area when human standing in an upright posture. Footprint depths are deformation in the calcaneal area obtained from the z-value extraction of the Boolean operation acquired from unloaded foot scanning using 3D scanner and loaded foot using foot plantar scanner. To compare peak loads estimated from footprint depth maximum, force sensing resistor (FSR) sensor is attached over the shoe insole with zero heel height in the calcaneal area. Twenty participants were selected from students of Mechanical Engineering Department Diponegoro University with the average the age and the body weight 19.5 years and 55.27 kg respectively. Results that were relatively accurate was found on the calcaneal loading estimation by footprint depth is presented by curve and data distribution which are in good agreement with the result of the measurement. A significant difference in estimating calcaneal loading is mainly caused by plantar foot position of research subjects which is not perpendicular to foot ankle and hallux. In addition, plantar foot position which bends to front/back/side affects the result of footprint depths.

  17. Pharmacokinetic Study of Piracetam in Focal Cerebral Ischemic Rats.

    Science.gov (United States)

    Paliwal, Pankaj; Dash, Debabrata; Krishnamurthy, Sairam

    2018-04-01

    Cerebral ischemia affects hepatic enzymes and brain permeability extensively. Piracetam was investigated up to phase III of clinical trials and there is lack of data on brain penetration in cerebral ischemic condition. Thus, knowledge of the pharmacokinetics and brain penetration of piracetam during ischemic condition would aid to improve pharmacotherapeutics in ischemic stroke. Focal cerebral ischemia was induced by middle cerebral artery occlusion for 2 h in male Wistar rats followed by reperfusion. After 24 h of middle cerebral artery occlusion or 22 h of reperfusion, piracetam was administered for pharmacokinetic, brain penetration, and pharmacological experiments. In pharmacokinetic study, blood samples were collected at different time points after 200-mg/kg (oral) and 75-mg/kg (intravenous) administration of piracetam through right external jugular vein cannulation. In brain penetration study, the cerebrospinal fluid, systemic blood, portal blood, and brain samples were collected at pre-designated time points after 200-mg/kg oral administration of piracetam. In a separate experiment, the pharmacological effect of the single oral dose of piracetam in middle cerebral artery occlusion was assessed at a dose of 200 mg/kg. All the pharmacokinetic parameters of piracetam including area under curve (AUC 0-24 ), maximum plasma concentration (C max ), time to reach the maximum plasma concentration (t max ), elimination half-life (t 1/2 ), volume of distribution (V z ), total body clearance, mean residence time, and bioavailability were found to be similar in ischemic stroke condition except for brain penetration. Piracetam exposure (AUC 0-2 ) in brain and CSF were found to be 2.4- and 3.1-fold higher, respectively, in ischemic stroke compared to control rats. Piracetam significantly reduced infarct volume by 35.77% caused by middle cerebral artery occlusion. There was no change in the pharmacokinetic parameters of piracetam in the ischemic stroke model except for

  18. Focal dystonia in musicians: From phenomenology to therapy

    Directory of Open Access Journals (Sweden)

    Hans-Christian Jabusch

    2006-01-01

    Full Text Available Background: Musician's dystonia is a task-specific movement disorder which manifests itself as a loss of voluntary motor control in extensively trained movements. In many cases, the disorder terminates the careers of affected musicians. Approximately 1% of all professional musicians are affected.Etiology and Pathophysiology: The pathophysiology of the disorder is still unclear. Findings include (a reduced inhibition in different levels of the central nervous system, (b maladaptive plasticity, e.g. in the somatosensory cortex and in the basal ganglia, and (c alterations in sensorimotor processing. Epidemiological data demon-strated a higher risk for those musicians who play instruments requiring maximal fine-motorskills. For instruments where workload differs across hands, focal dystonia appears more often in the more intensely used hand. In psychological studies, musicians with dystonia had more perfectionist tendencies than healthy musicians. These findings streng then the assumption that behavioral factors may be involved in the etiology of musician's dystonia. Hereditary factors may play a greater role than previously assumed. Preliminary findings suggest a genetic contributiont o focal task-specific dystonia with phenotypic variations including musician's dystonia.Treatment: Treatment options for musician's dystonia include pharmacological interventions such as administration of Trihexyphenidyl or Botulinum Toxin-A as well as retraining programs and ergonomic changes in the instrument. A long-term follow-up study was performed in 144 patients with musician's dystonia. The outcome was revealed on average 8.4 years after onset of symptoms. Outcome was assessed by patients' subjective rating of cumulative treatmentresponse and response to individual therapies. Seventy-seven patients (54% reported an alleviation of symptoms: 33% of the patients with Trihexyphenidyl, 49% with Botulinum Toxin, 50% with pedagogical retraining, 56% with unmonitored

  19. Serial neuroradiological studies in focal cerebritis

    International Nuclear Information System (INIS)

    Hatta, S.; Mochizuki, H.; Kuru, Y.; Miwa, H.; Kondo, T.; Mori, H.; Mizuno, Y.

    1994-01-01

    We report serial neuroradiological studies in a patient with focal cerebritis in the head of the left caudate nucleus. On the day after the onset of symptoms, CT showed an ill-defined low density lesion. The lack of contrast enhancement appeared to be the most important finding for differentiating focal cerebritis from an encapsulated brain abscess or a tumour. MRI two days later revealed the centre of the lesion to be of slightly low intensity on T1-weighted inversion recovery (IR) images and very low intensity on T2-weighted spin echo images, which appeared to correspond to the early cerebritis stage of experimentally induced cerebritis and brain abscess. Ten days after the onset of symptoms, CT revealed a thin ring of enhancement in the head of the caudate nucleus, and a similar small ring was seen in the hypothalamus 16 days after the onset, corresponding to the late cerebritis stage. MRI nine days later revealed ill-defined high signal lesions within the involved area on the T1-weighted IR images. To our knowledge, this is the first published MRI documentation of the early cerebritis stage developing into an encapsulated brain abscess. The mechanisms underlying of these radiographic changes are discussed. (orig.)

  20. Focal femoral condyle resurfacing.

    LENUS (Irish Health Repository)

    Brennan, S A

    2013-03-01

    Focal femoral inlay resurfacing has been developed for the treatment of full-thickness chondral defects of the knee. This technique involves implanting a defect-sized metallic or ceramic cap that is anchored to the subchondral bone through a screw or pin. The use of these experimental caps has been advocated in middle-aged patients who have failed non-operative methods or biological repair techniques and are deemed unsuitable for conventional arthroplasty because of their age. This paper outlines the implant design, surgical technique and biomechanical principles underlying their use. Outcomes following implantation in both animal and human studies are also reviewed. Cite this article: Bone Joint J 2013;95-B:301-4.

  1. Uncooled infrared focal plane array imaging in China

    Science.gov (United States)

    Lei, Shuyu

    2015-06-01

    This article reviews the development of uncooled infrared focal plane array (UIFPA) imaging in China in the past decade. Sensors based on optical or electrical read-out mechanism were developed but the latter dominates the market. In resistive bolometers, VOx and amorphous silicon are still the two major thermal-sensing materials. The specifications of the IRFPA made by different manufactures were collected and compared. Currently more than five Chinese companies and institutions design and fabricate uncooled infrared focal plane array. Some devices have sensitivity as high as 30 mK; the largest array for commercial products is 640×512 and the smallest pixel size is 17 μm. Emphasis is given on the pixel MEMS design, ROIC design, fabrication, and packaging of the IRFPA manufactured by GWIC, especially on design for high sensitivities, low noise, better uniformity and linearity, better stabilization for whole working temperature range, full-digital design, etc.

  2. Power of the Poincaré group: elucidating the hidden symmetries in focal conic domains.

    Science.gov (United States)

    Alexander, Gareth P; Chen, Bryan Gin-Ge; Matsumoto, Elisabetta A; Kamien, Randall D

    2010-06-25

    Focal conic domains are typically the "smoking gun" by which smectic liquid crystalline phases are identified. The geometry of the equally spaced smectic layers is highly generic but, at the same time, difficult to work with. In this Letter we develop an approach to the study of focal sets in smectics which exploits a hidden Poincaré symmetry revealed only by viewing the smectic layers as projections from one-higher dimension. We use this perspective to shed light upon several classic focal conic textures, including the concentric cyclides of Dupin, polygonal textures, and tilt-grain boundaries.

  3. Axial and focal-plane diffraction catastrophe integrals

    International Nuclear Information System (INIS)

    Berry, M V; Howls, C J

    2010-01-01

    Exact expressions in terms of Bessel functions are found for some of the diffraction catastrophe integrals that decorate caustics in optics and mechanics. These are the axial and focal-plane sections of the elliptic and hyperbolic umbilic diffraction catastrophes, and symmetric elliptic and hyperbolic unfoldings of the X 9 diffraction catastrophes. These representations reveal unexpected relations between the integrals.

  4. Poster - 47: A parametrized prediction model of rectal toxicity in focal SBRT of low risk prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, Todd; Bauman, Glenn [Saint John Regional Hospital, London Regional Cancer Program (Canada)

    2016-08-15

    There has been a recent trend towards watchful waiting in place of intervention for early stage prostate cancer (CaP). However, this approach can allow for disease progression, and subsequent whole-gland therapies such as prostatectomy and whole gland irradiation can result in functional deficits or rectal toxicities or both. A controversial alternative approach for this patient cohort is the use of focal therapy, where the treatment is focussed on an identified dominant index lesion (DIL). This work aims to investigate the treatment parameters for focal SBRT of the prostate under which clinically acceptable rectal NTCP levels can be achieved. For each of 25 low risk CaP patients, a hypothetical 2 cc DIL was modeled in the right-posterior quadrant of the prostate, and was used to build a PTV as the target for SBRT simulation. An SBRT prescriptions of 41 Gy and 37 Gy in 5 fractions were chosen, corresponding to the boost levels used in previous CaP dose escalation studies. DVH data were exported and used to calculate rectal NTCP values based on the Lyman-Kutcher-Burman (LKB) model using the QUANTEC reccommended model parameters. Rectal NTCP dependence on DIL-to-rectum separation, dose level, and DIL volume were investigated. The final goal of this ongoing work is to create a map of the maximum allowable prescription dose for a given patient geometry that achieves a clinically acceptable rectal NTCP level.

  5. Numerical study and ex vivo assessment of HIFU treatment time reduction through optimization of focal point trajectory

    Science.gov (United States)

    Grisey, A.; Yon, S.; Pechoux, T.; Letort, V.; Lafitte, P.

    2017-03-01

    Treatment time reduction is a key issue to expand the use of high intensity focused ultrasound (HIFU) surgery, especially for benign pathologies. This study aims at quantitatively assessing the potential reduction of the treatment time arising from moving the focal point during long pulses. In this context, the optimization of the focal point trajectory is crucial to achieve a uniform thermal dose repartition and avoid boiling. At first, a numerical optimization algorithm was used to generate efficient trajectories. Thermal conduction was simulated in 3D with a finite difference code and damages to the tissue were modeled using the thermal dose formula. Given an initial trajectory, the thermal dose field was first computed, then, making use of Pontryagin's maximum principle, the trajectory was iteratively refined. Several initial trajectories were tested. Then, an ex vivo study was conducted in order to validate the efficicency of the resulting optimized strategies. Single pulses were performed at 3MHz on fresh veal liver samples with an Echopulse and the size of each unitary lesion was assessed by cutting each sample along three orthogonal planes and measuring the dimension of the whitened area based on photographs. We propose a promising approach to significantly shorten HIFU treatment time: the numerical optimization algorithm was shown to provide a reliable insight on trajectories that can improve treatment strategies. The model must now be improved in order to take in vivo conditions into account and extensively validated.

  6. [Functional connectivity and complex networks in focal epilepsy. Pathophysiology and therapeutic implications].

    Science.gov (United States)

    Pastor, Jesús; Sola, Rafael G; Vega-Zelaya, Lorena; Garnes, Óscar; Ortega, Guillermo J

    2014-05-01

    The traditional surgical approach to treat drug-resistant focal epileptic patients is in the resection or disconnection of the epileptic focus. However, a significant minority of patients continue to experience seizures after surgery, which shows the incomplete level of knowledge that currently we have of this pathology. This paper introduces some concepts of functional connectivity and complex networks methodology with its application to the study of neurophysiological recordings from patients suffering from drug-resistant focal epilepsy. In order to fully understand the new developments in the area of complex networks and its applications to the study of epilepsy, we will here review fundamental concepts in complex networks methodology, synchronization and functional connectivity. Some of the most recent published works dealing with focal epilepsy viewed under this new perspective will be revised and commented. We think that a wider perspective in the study of epilepsy, such as the one reviewed in this work, will allow epileptologists to consider surgical alternatives in the usual treatment of focal epilepsy at those currently performed in most medical centers around the world. Combining the traditional knowledge with new insights provided by network theory will certainly fill many of the gaps we have today in the fragmented understanding of epilepsy.

  7. FAK dimerization controls its kinase-dependent functions at focal adhesions

    KAUST Repository

    Brami-Cherrier, Karen; Gervasi, Nicolas; Arsenieva, Diana A.; Walkiewicz, Katarzyna; Boutterin, Marie Claude; Ortega, Á lvaro Darí o; Leonard, Paul G.; Seantier, Bastien; Gasmi, Laï la; Bouceba, Tahar; Kadaré , Gress; Girault -, Jean Antoine; Arold, Stefan T.

    2014-01-01

    Focal adhesion kinase (FAK) controls adhesion-dependent cell motility, survival, and proliferation. FAK has kinase-dependent and kinase-independent functions, both of which play major roles in embryogenesis and tumor invasiveness. The precise mechanisms of FAK activation are not known. Using x-ray crystallography, small angle x-ray scattering, and biochemical and functional analyses, we show that the key step for activation of FAK's kinase-dependent functions-autophosphorylation of tyrosine-397-requires site-specific dimerization of FAK. The dimers form via the association of the N-terminal FERM domain of FAK and are stabilized by an interaction between FERM and the C-terminal FAT domain. FAT binds to a basic motif on FERM that regulates co-activation and nuclear localization. FAK dimerization requires local enrichment, which occurs specifically at focal adhesions. Paxillin plays a dual role, by recruiting FAK to focal adhesions and by reinforcing the FAT:FERM interaction. Our results provide a structural and mechanistic framework to explain how FAK combines multiple stimuli into a site-specific function. The dimer interfaces we describe are promising targets for blocking FAK activation. © 2014 The Authors.

  8. FAK dimerization controls its kinase-dependent functions at focal adhesions

    KAUST Repository

    Brami-Cherrier, Karen

    2014-01-30

    Focal adhesion kinase (FAK) controls adhesion-dependent cell motility, survival, and proliferation. FAK has kinase-dependent and kinase-independent functions, both of which play major roles in embryogenesis and tumor invasiveness. The precise mechanisms of FAK activation are not known. Using x-ray crystallography, small angle x-ray scattering, and biochemical and functional analyses, we show that the key step for activation of FAK\\'s kinase-dependent functions-autophosphorylation of tyrosine-397-requires site-specific dimerization of FAK. The dimers form via the association of the N-terminal FERM domain of FAK and are stabilized by an interaction between FERM and the C-terminal FAT domain. FAT binds to a basic motif on FERM that regulates co-activation and nuclear localization. FAK dimerization requires local enrichment, which occurs specifically at focal adhesions. Paxillin plays a dual role, by recruiting FAK to focal adhesions and by reinforcing the FAT:FERM interaction. Our results provide a structural and mechanistic framework to explain how FAK combines multiple stimuli into a site-specific function. The dimer interfaces we describe are promising targets for blocking FAK activation. © 2014 The Authors.

  9. Kalman Filter for Calibrating a Telescope Focal Plane

    Science.gov (United States)

    Kang, Bryan; Bayard, David

    2006-01-01

    The instrument-pointing frame (IPF) Kalman filter, and an algorithm that implements this filter, have been devised for calibrating the focal plane of a telescope. As used here, calibration signifies, more specifically, a combination of measurements and calculations directed toward ensuring accuracy in aiming the telescope and determining the locations of objects imaged in various arrays of photodetectors in instruments located on the focal plane. The IPF Kalman filter was originally intended for application to a spaceborne infrared astronomical telescope, but can also be applied to other spaceborne and ground-based telescopes. In the traditional approach to calibration of a telescope, (1) one team of experts concentrates on estimating parameters (e.g., pointing alignments and gyroscope drifts) that are classified as being of primarily an engineering nature, (2) another team of experts concentrates on estimating calibration parameters (e.g., plate scales and optical distortions) that are classified as being primarily of a scientific nature, and (3) the two teams repeatedly exchange data in an iterative process in which each team refines its estimates with the help of the data provided by the other team. This iterative process is inefficient and uneconomical because it is time-consuming and entails the maintenance of two survey teams and the development of computer programs specific to the requirements of each team. Moreover, theoretical analysis reveals that the engineering/ science iterative approach is not optimal in that it does not yield the best estimates of focal-plane parameters and, depending on the application, may not even enable convergence toward a set of estimates.

  10. Radio Telescope Focal Container for the Russian VLBI Network of New Generation

    Science.gov (United States)

    Ipatov, Alexander; Mardyshkin, Vyacheslav; Cherepanov, Andrey; Chernov, Vitaly; Diky, Dmitry; Khvostov, Evgeny; Yevstigneyev, Alexander

    2010-01-01

    This article considers the development of the structure of receivers for Russian radio telescopes. The development of these radio telescopes is undertaken within the project for creating a Russian small-antenna-based radio interferometer of new generation. It is shown that for small antennas (10. 12 meter) the principal unit, which provides the best SNR, is the so-called focal container placed at primary focus. It includes the primary feed, HEMT LNA, and cryogenic cooling system down to 20. K. A new multi-band feed based on traveling wave resonators is used. It has small dimensions, low weight, and allows working with circular polarizations. Thus it can be placed into focal container and cooled with the LNA. A sketch of the focal container, with traveling-wave-resonator feed, and calculations of the expected parameters of the multi-band receiver are presented.

  11. Fibrocystic change of the breast presenting as a focal lesion mimicking breast cancer in MR imaging.

    Science.gov (United States)

    Chen, Jeon-Hor; Nalcioglu, Orhan; Su, Min-Ying

    2008-12-01

    Focal fibrocystic change (FCC) of the breast is a rare form of FCC. Imaging presentations of focal FCC are not well known. This study aimed to analyze its MR imaging features. Eleven patients of pathology-proven focal FCC were retrospectively studied. Of the 11 patients, seven were mass (>or=5 mm), two showed multiple foci, and two were focus (Breast sonography suspected malignancy in seven patients (7/10, 70%). No statistically significant difference was found in the three diagnostic methods. In pathology, all 11 patients showed the typical pathological features of fibrocystic change, with mixed components of stromal fibrosis, cyst formation, apocrine metaplasia, adenosis, and/or focal sclerosing adenosis. In conclusion, MR imaging features of focal FCC usually present as a mass or focus lesion with rapid enhancement and washout kinetics that mimic a malignant breast lesion and lead to unnecessary operation, especially in patients with contralateral malignant breast cancer. (c) 2008 Wiley-Liss, Inc.

  12. Large-format InGaAs focal plane arrays for SWIR imaging

    Science.gov (United States)

    Hood, Andrew D.; MacDougal, Michael H.; Manzo, Juan; Follman, David; Geske, Jonathan C.

    2012-06-01

    FLIR Electro Optical Components will present our latest developments in large InGaAs focal plane arrays, which are used for low light level imaging in the short wavelength infrared (SWIR) regime. FLIR will present imaging from their latest small pitch (15 μm) focal plane arrays in VGA and High Definition (HD) formats. FLIR will present characterization of the FPA including dark current measurements as well as the use of correlated double sampling to reduce read noise. FLIR will show imagery as well as FPA-level characterization data.

  13. Ultrasound and computer tomography in the evaluation of focal liver disease

    Energy Technology Data Exchange (ETDEWEB)

    Bartolozzi, C; Ciatti, S; Lucarelli, E; Villari, N; de Dominicis, R [Florence Univ. (Italy). Ist. di Radiologia

    1981-01-01

    The results of ultrasound and computer tomography in 150 patients with possible focal liver disease were compared. Ultrasound was more sensitive than CT in detecting lesions but similar information on the nature of the lesion was obtained with both methods. CT provided more complete information than US on the extent of the lesion. Thus, CT and US are supplementary in the evaluation of focal liver disease. Because of the higher sensitivity US should be the first examination, followed, if clinically indicated, by CT for confirmation and possible further information regarding the extent of the lesion.

  14. Approximate maximum parsimony and ancestral maximum likelihood.

    Science.gov (United States)

    Alon, Noga; Chor, Benny; Pardi, Fabio; Rapoport, Anat

    2010-01-01

    We explore the maximum parsimony (MP) and ancestral maximum likelihood (AML) criteria in phylogenetic tree reconstruction. Both problems are NP-hard, so we seek approximate solutions. We formulate the two problems as Steiner tree problems under appropriate distances. The gist of our approach is the succinct characterization of Steiner trees for a small number of leaves for the two distances. This enables the use of known Steiner tree approximation algorithms. The approach leads to a 16/9 approximation ratio for AML and asymptotically to a 1.55 approximation ratio for MP.

  15. Experimental research on energy circled fraction of continuous phase plates in focal spot

    International Nuclear Information System (INIS)

    Zhang Yuanhang; Yang Chunlin; Wen Shenglin; Shi Qikai; Wang Jian

    2013-01-01

    In inertial confinement fusion (ICF) research process, the form of focal spot is extremely crucial. Especially in the indirect driven implosion, energy circled fraction is higher than 95% in focal spot. Based on the offline test platform, the focusing spot of continuous phase plates with different application error is clearly imaged on CCD. By experimental analysis, it is found that the beam rotation error, caliber error, translational error and inclination error have a high tolerance in affecting focal plane of CPP. Energy circled fraction is higher than 95%, the range is less than 0.5%. Nevertheless, the waterfront aberration seriously affects the shaping ability of the CPP. Clearly, the main factor of reducing energy circled fraction to less than 90% is waterfront aberration. (authors)

  16. Weighted halfspace depth

    Czech Academy of Sciences Publication Activity Database

    Kotík, Lukáš; Hlubinka, D.; Vencálek, O.

    Vol. 46, č. 1 (2010), s. 125-148 ISSN 0023-5954 Institutional research plan: CEZ:AV0Z10750506 Keywords : data depth * nonparametric multivariate analysis * strong consistency of depth * mixture of distributions Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.461, year: 2010 http://library.utia.cas.cz/separaty/2010/SI/kotik-weighted halfspace depth.pdf

  17. Minimum decoding trellis length and truncation depth of wrap-around Viterbi algorithm for TBCC in mobile WiMAX

    Directory of Open Access Journals (Sweden)

    Liu Yu-Sun

    2011-01-01

    Full Text Available Abstract The performance of the wrap-around Viterbi decoding algorithm with finite truncation depth and fixed decoding trellis length is investigated for tail-biting convolutional codes in the mobile WiMAX standard. Upper bounds on the error probabilities induced by finite truncation depth and the uncertainty of the initial state are derived for the AWGN channel. The truncation depth and the decoding trellis length that yield negligible performance loss are obtained for all transmission rates over the Rayleigh channel using computer simulations. The results show that the circular decoding algorithm with an appropriately chosen truncation depth and a decoding trellis just a fraction longer than the original received code words can achieve almost the same performance as the optimal maximum likelihood decoding algorithm in mobile WiMAX. A rule of thumb for the values of the truncation depth and the trellis tail length is also proposed.

  18. Constrained Adherable Area of Nanotopographic Surfaces Promotes Cell Migration through the Regulation of Focal Adhesion via Focal Adhesion Kinase/Rac1 Activation.

    Science.gov (United States)

    Lim, Jiwon; Choi, Andrew; Kim, Hyung Woo; Yoon, Hyungjun; Park, Sang Min; Tsai, Chia-Hung Dylan; Kaneko, Makoto; Kim, Dong Sung

    2018-05-02

    Cell migration is crucial in physiological and pathological processes such as embryonic development and wound healing; such migration is strongly guided by the surrounding nanostructured extracellular matrix. Previous studies have extensively studied the cell migration on anisotropic nanotopographic surfaces; however, only a few studies have reported cell migration on isotropic nanotopographic surfaces. We herein, for the first time, propose a novel concept of adherable area on cell migration using isotropic nanopore surfaces with sufficient nanopore depth by adopting a high aspect ratio. As the pore size of the nanopore surface was controlled to 200, 300, and 400 nm in a fixed center-to-center distance of 480 nm, it produced 86, 68, and 36% of adherable area, respectively, on the fabricated surface. A meticulous investigation of the cell migration in response to changes in the constrained adherable area of the nanotopographic surface showed 1.4-, 1.5-, and 1.6-fold increase in migration speeds and a 1.4-, 2-, and 2.5-fold decrease in the number of focal adhesions as the adherable area was decreased to 86, 68, and 36%, respectively. Furthermore, a strong activation of FAK/Rac1 signaling was observed to be involved in the promoted cell migration. These results suggest that the reduced adherable area promotes cell migration through decreasing the FA formation, which in turn upregulates FAK/Rac1 activation. The findings in this study can be utilized to control the cell migration behaviors, which is a powerful tool in the research fields involving cell migration such as promoting wound healing and tissue repair.

  19. Segmented focal plane detector for light and heavy ions

    International Nuclear Information System (INIS)

    Wolfs, F.L.H.; Bryan, D.C.; Kurz, K.L.; Herrick, D.M.; Perera, P.A.A.; White, C.A.

    1992-01-01

    A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.)

  20. Laser Beam Caustic Measurement with Focal Spot Analyser

    DEFF Research Database (Denmark)

    Olsen, Flemming Ove; Gong, Hui; Bagger, Claus

    2005-01-01

    In industrial applications of high power CO2-lasers the caustic characteristics of the laser beam have great effects on the performance of the lasers. A welldefined high intense focused spot is essential for reliable production results. This paper presents a focal spot analyser that is developed...

  1. Focal sparing around the gallbladder in fatty liver

    International Nuclear Information System (INIS)

    Chen, Kemin; Hiramatsu, Yoshihiro; Yunoki, Masanori; Hirano, Yoko

    1989-01-01

    In evaluating fatty liver with CT, the residual normal liver tissues without fat deposits are occasionally detected on CT as high attenuation regions, especially surrounding the gallbladder. This study examined the incidence of this phenomenon in terms of the diagnostic value of CT in fatty liver. Fifty-seven patients with fatty liver were examined with CT. The incidence of focal sparing area was the highest in the gallbladder bed (42/57, 74%), followed by the interlobar fissure or subcapsular area (13, 23%), quadrate lobe (8, 14%), caudate lobe (2, 4%), and right lobe (one, 1.8%). These CT appearances were of spot, band, ring, and the mixed type. In 38 patients, fatty liver was too moderate to be detected without CT attenuation numbers. Among them, 27 patients (71%) had focal sparing area surrounding the gallbladder. This CT appearance seemed to be of significance in preventing the missing of moderate fatty liver. (Namekawa, K)

  2. High operating temperature interband cascade focal plane arrays

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Z.-B.; Godoy, S. E.; Kim, H. S.; Schuler-Sandy, T.; Montoya, J. A.; Krishna, S. [Center for High Technology Materials, Department of Electrical and Computer Engineering, University of New Mexico, Albuquerque, New Mexico 87106 (United States)

    2014-08-04

    In this paper, we report the initial demonstration of mid-infrared interband cascade (IC) photodetector focal plane arrays with multiple-stage/junction design. The merits of IC photodetectors include low noise and efficient photocarrier extraction, even for zero-bias operation. By adopting enhanced electron barrier design and a total absorber thickness of 0.7 μm, the 5-stage IC detectors show very low dark current (1.10 × 10{sup −7} A/cm{sup 2} at −5 mV and 150 K). Even with un-optimized fabrication and standard commercial (mis-matched) read-out circuit technology, infrared images are obtained by the 320 × 256 IC focal plane array up to 180 K with f/2.3 optics. The minimum noise equivalent temperature difference of 28 mK is obtained at 120 K. These initial results indicate great potential of IC photodetectors, particularly for high operating temperature applications.

  3. High operating temperature interband cascade focal plane arrays

    International Nuclear Information System (INIS)

    Tian, Z.-B.; Godoy, S. E.; Kim, H. S.; Schuler-Sandy, T.; Montoya, J. A.; Krishna, S.

    2014-01-01

    In this paper, we report the initial demonstration of mid-infrared interband cascade (IC) photodetector focal plane arrays with multiple-stage/junction design. The merits of IC photodetectors include low noise and efficient photocarrier extraction, even for zero-bias operation. By adopting enhanced electron barrier design and a total absorber thickness of 0.7 μm, the 5-stage IC detectors show very low dark current (1.10 × 10 −7 A/cm 2 at −5 mV and 150 K). Even with un-optimized fabrication and standard commercial (mis-matched) read-out circuit technology, infrared images are obtained by the 320 × 256 IC focal plane array up to 180 K with f/2.3 optics. The minimum noise equivalent temperature difference of 28 mK is obtained at 120 K. These initial results indicate great potential of IC photodetectors, particularly for high operating temperature applications

  4. Focal dermal hypoplasia: A rare case report

    Directory of Open Access Journals (Sweden)

    Sahana M Srinivas

    2015-01-01

    Full Text Available Focal dermal hypoplasia (Goltz syndrome is a rare genetic multisystem disorder primarily involving the skin, skeletal system, eyes, and face. We report the case of an eight-month-old female child who presented with multiple hypopigmented atrophic macules along the lines of blaschko, skeletal anomalies, umbilical hernia, developmental delay, hypoplastic nails, syndactyly, and lobster claw deformity characteristic of Goltz syndrome.

  5. Affection of blood supply of focal hepatic mass on apparent diffusion coefficient of the lesions

    International Nuclear Information System (INIS)

    Chen Zaizhi; Wu Yulin; Xu Zhongfei; Yang Zhenghan; Chen Min; Zhou Cheng; Xie Jingxia

    2002-01-01

    Objective: To investigate the affection of lesion blood supply on apparent diffusion coefficient (ADC) of focal hepatic mass. Methods: Diffusion-weighted imaging (DWI) with different b values was performed in 87 patients with 159 focal hepatic lesions. ADCs of lesion, liver, spleen, gallbladder were measured in every case. Results: On DWI with small b value and small b value remainder, ADCs were affected by blood perfusion of tissues or lesions. The mean ADC of hypervascular lesions was significantly higher than that of hypovascular lesions on DWI with small b value, and hemoangiomas got the highest mean ADC. The mean ADC of hepatic cysts was not affected by b value. Conclusion: Blood perfusion affects ADC of tissue or focal hepatic lesion, particularly on DWI with small b value, and to some degree, DWI and ADC can reflect the blood supply of focal hepatic lesion

  6. Focal intestinal lymphangiectasia: An unusual cause of acute overt obscure gastrointestinal bleeding

    Directory of Open Access Journals (Sweden)

    Ashish Kumar Jha

    2014-01-01

    Full Text Available Detection of bleeding lesion in a patient of acute overt obscure gastrointestinal bleeding is a real challenge. Recently, authors have showed superiority of urgent capsule endoscopy (CE over angiography in patients with acute overt obscure gastrointestinal bleeding. Focal type of intestinal lymphangiectasia is a rare cause of acute gastrointestinal bleeding. Here, we describe a case of focal lymphangiectasia who presented to us with acute overt obscure gastrointestinal bleeding and diagnosed by urgent CE.

  7. Combining PALM and SOFI for quantitative imaging of focal adhesions in living cells

    Science.gov (United States)

    Deschout, Hendrik; Lukes, Tomas; Sharipov, Azat; Feletti, Lely; Lasser, Theo; Radenovic, Aleksandra

    2017-02-01

    Focal adhesions are complicated assemblies of hundreds of proteins that allow cells to sense their extracellular matrix and adhere to it. Although most focal adhesion proteins have been identified, their spatial organization in living cells remains challenging to observe. Photo-activated localization microscopy (PALM) is an interesting technique for this purpose, especially since it allows estimation of molecular parameters such as the number of fluorophores. However, focal adhesions are dynamic entities, requiring a temporal resolution below one minute, which is difficult to achieve with PALM. In order to address this problem, we merged PALM with super-resolution optical fluctuation imaging (SOFI) by applying both techniques to the same data. Since SOFI tolerates an overlap of single molecule images, it can improve the temporal resolution compared to PALM. Moreover, an adaptation called balanced SOFI (bSOFI) allows estimation of molecular parameters, such as the fluorophore density. We therefore performed simulations in order to assess PALM and SOFI for quantitative imaging of dynamic structures. We demonstrated the potential of our PALM-SOFI concept as a quantitative imaging framework by investigating moving focal adhesions in living cells.

  8. CAMAC module control from the TPA-1001/i by means of the FOCAL programming language

    International Nuclear Information System (INIS)

    Angelov, A.Kh.; Dubovik, L.V.

    1977-01-01

    The possibility of using FOCAL programming language to control CAMAC modules by minicomputer is considered. This language allows to make effective changes in the program and reduce the time necessary for writing and running programmes. To address CAMAC modules a packet of CAMAC subroutines from the CAMAC-tr A/i software is included into FOCAL language, its operational possibilities and linguistic peculiarities being completely preserved. A big fast memory enables one to add three additional functions to the function list of FOCAL language. An example is given illustrating the use of these functions

  9. High Frequency High Spectral Resolution Focal Plane Arrays for AtLAST

    Science.gov (United States)

    Baryshev, Andrey

    2018-01-01

    Large collecting area single dish telescope such as ATLAST will be especially effective for medium (R 1000) and high (R 50000) spectral resolution observations. Large focal plane array is a natural solution to increase mapping speed. For medium resolution direct detectors with filter banks (KIDs) and or heterodyne technology can be employed. We will analyze performance limits of comparable KID and SIS focal plane array taking into account quantum limit and high background condition of terrestrial observing site. For large heterodyne focal plane arrays, a high current density AlN junctions open possibility of large instantaneous bandwidth >40%. This and possible multi frequency band FPSs presents a practical challenge for spatial sampling and scanning strategies. We will discuss phase array feeds as a possible solution, including a modular back-end system, which can be shared between KID and SIS based FPA. Finally we will discuss achievable sensitivities and pixel co unts for a high frequency (>500 GHz) FPAs and address main technical challenges: LO distribution, wire counts, bias line multiplexing, and monolithic vs. discrete mixer component integration.

  10. Interferon Induced Focal Segmental Glomerulosclerosis

    Directory of Open Access Journals (Sweden)

    Yusuf Kayar

    2016-01-01

    Full Text Available Behçet’s disease is an inflammatory disease of unknown etiology which involves recurring oral and genital aphthous ulcers and ocular lesions as well as articular, vascular, and nervous system involvement. Focal segmental glomerulosclerosis (FSGS is usually seen in viral infections, immune deficiency syndrome, sickle cell anemia, and hyperfiltration and secondary to interferon therapy. Here, we present a case of FSGS identified with kidney biopsy in a patient who had been diagnosed with Behçet’s disease and received interferon-alpha treatment for uveitis and presented with acute renal failure and nephrotic syndrome associated with interferon.

  11. Computational model of neuron-astrocyte interactions during focal seizure generation

    Directory of Open Access Journals (Sweden)

    Davide eReato

    2012-10-01

    Full Text Available Empirical research in the last decade revealed that astrocytes can respond to neurotransmitters with Ca2+ elevations and generate feedback signals to neurons which modulate synaptic transmission and neuronal excitability. This discovery changed our basic understanding of brain function and provided new perspectives for how astrocytes can participate not only to information processing, but also to the genesis of brain disorders, such as epilepsy. Epilepsy is a neurological disorder characterized by recurrent seizures that can arise focally at restricted areas and propagate throughout the brain. Studies in brain slice models suggest that astrocytes contribute to epileptiform activity by increasing neuronal excitability through a Ca2+-dependent release of glutamate. The underlying mechanism remains, however, unclear. In this study, we implemented a parsimonious network model of neurons and astrocytes. The model consists of excitatory and inhibitory neurons described by Izhikevich's neuron dynamics. The experimentally observed Ca2+ change in astrocytes in response to neuronal activity was modeled with linear equations. We considered that glutamate is released from astrocytes above certain intracellular Ca2+ concentrations thus providing a non-linear positive feedback signal to neurons. Propagating seizure-like ictal discharges (IDs were reliably evoked in our computational model by repeatedly exciting a small area of the network, which replicates experimental results in a slice model of focal ID in entorhinal cortex. We found that the threshold of focal ID generation was lowered when an excitatory feedback-loop between astrocytes and neurons was included. Simulations show that astrocytes can contribute to ID generation by directly affecting the excitatory/inhibitory balance of the neuronal network. Our model can be used to obtain mechanistic insights into the distinct contributions of the different signaling pathways to the generation and

  12. Recurrent Focal Myositis in Childhood: A Case Report and Systematic Review of the Literature.

    Science.gov (United States)

    Milani, Gregorio P; Mazzoni, Marta B M; Gatti, Helga; Bertolozzi, Giuseppe; Fossali, Emilio F

    2017-06-01

    Recurrent focal myositis in adulthood has been documented in case reports and case series. Existing textbooks and reviews do not mention or mention only in passing this entity in childhood. We present a patient with recurrent focal myositis and summarize available clinical, laboratory, management, and outcome data on this entity in the pediatric ages. We describe a nine-year-old patient with recurrent myositis of the left biceps. The terms "myositis" and "relapsing" or "recurrent" or "recurrence" were searched using the United States National Library of Medicine and the Excerpta Medica Database. Pertinent secondary references were also screened. Another seven pediatric patients (five males and two females, median age ten years, interquartile range 7-14 years) with recurrent focal myositis were identified. In children, the calf was the most frequently involved muscle. Unlike adults, the myositis in children was usually painful. Episodes could be associated with normal or elevated erythrocyte sedimentation rate and blood levels of C-reactive protein, creatine kinase, and aspartate aminotransferase. Abnormalities of the creatine kinase value did not seem to be associated with a higher risk of recurrences. Focal myositis has a favorable outcome in children. Recurrent focal myositis is rare and usually benign in childhood. More data are needed to improve the understanding of this condition. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. The design of a focused ultrasound transducer array for the treatment of stroke: a simulation study

    International Nuclear Information System (INIS)

    Pajek, Daniel; Hynynen, Kullervo

    2012-01-01

    High intensity focused ultrasound (HIFU) is capable of mechanically disintegrating blood clots at high pressures. Safe thrombolysis may require frequencies higher than those currently utilized by transcranial HIFU. Since the attenuation and focal distortion of ultrasound in bone increases at higher frequencies, resulting focal pressures are diminished. This study investigated the feasibility of using transcranial HIFU for the non-invasive treatment of ischemic stroke. The use of large aperture, 1.1–1.5 MHz phased arrays in targeting four clinically relevant vessel locations was simulated. Resulting focal sizes decreased with frequency, producing a maximum –3 dB depth of field and lateral width of 2.0 and 1.2 mm, respectively. Mean focal gains above an order of magnitude were observed in three of four targets and transducer intensities required to achieve thrombolysis were determined. Required transducer element counts are about an order of magnitude higher than what currently exists and so, although technically feasible, new arrays would need to be developed to realize this as a treatment modality for stroke. (paper)

  14. The case for focal brachytherapy for the management of low grade prostate cancer

    International Nuclear Information System (INIS)

    Allen, B.J.; Enari, E.

    2011-01-01

    Full text: Radical therapy of low to intermediate prostate cancer patients can cause substantial adverse events relating to genitourinary and rectal toxicity. Yet there is little evidence that such treatment results in increased life expectancy. On the other hand, watchful waiting is associated with active surveillance and the patient must accept that the cancer remains untreated and has a risk of progression. Focal therapy of low grade prostate cancer provides an intermediate approach to the management of this cancer. The approach is to treat only those positive segments on biopsy and so reduce the likelihood of adverse events. However, continued surveillance is required because of the increased risk of disease progression. Focal therapy needs to be evaluated using available ablative therapies. Recent studies of focal HIFU for 20 patients showed PSA reduced from 7.3 to 1.5 ng/mL at 12 months. 1/20 patients had inadequate erections and 2120 required pads. 17/19 had no histological evidence of cancer and none had evidence of high volume or Gleason = 7 cancer in the treated lobe. Seed brachytherapy is commonly used for radical prostate treatment of low volume disease. As the same template can be used for seed therapy as is used for biopsy, the technique is ideally suited for focal brachytherapy. As any treatment involving less than the entire gland involves the risk of leaving viable cancer cells outside the treatment zone, a phase 3 randomised clinical trial between radical and focal brachytherapy is advocated to demonstrate the efficacy and safety of the latter relative to radical therapy.

  15. Statin-induced focal myositis of the upper extremity. A report of two cases

    International Nuclear Information System (INIS)

    Wagner, M.; Muehldorfer-Fodor, M.; Prommersberger, K.J.; Schmitt, R.

    2011-01-01

    Statins are widely used to lower increased cholesterol levels with the aim to prevent major cardiovascular events. However, they bare the risk of myotoxic side effects. We report on two patients with focal weakness and pain in the upper extremities. In both patients, abnormal MRI signal heights in the muscle groups involved were indicative of the final diagnosis of focal myositis during statin therapy.

  16. Statin-induced focal myositis of the upper extremity. A report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, M., E-mail: wagner.radiologie@herzchirurgie.de [Department of Radiology, Herz- und Gefaessklinik GmbH, Salzburger Leite 1, D-97616 Bad Neustadt an der Saale (Germany); Muehldorfer-Fodor, M.; Prommersberger, K.J. [Department of Handsurgery, Herz- und Gefaessklinik GmbH, Bad Neustadt an der Saale (Germany); Schmitt, R. [Department of Radiology, Herz- und Gefaessklinik GmbH, Salzburger Leite 1, D-97616 Bad Neustadt an der Saale (Germany)

    2011-02-15

    Statins are widely used to lower increased cholesterol levels with the aim to prevent major cardiovascular events. However, they bare the risk of myotoxic side effects. We report on two patients with focal weakness and pain in the upper extremities. In both patients, abnormal MRI signal heights in the muscle groups involved were indicative of the final diagnosis of focal myositis during statin therapy.

  17. Automatic test comes to focal plane array production

    Science.gov (United States)

    Skaggs, Frank L.; Barton, T. D.

    1992-08-01

    To meet the needs of military and commercial markets, the infrared focal plane array industry must develop new, effective and low cost methods of fabricating and testing imaging detectors. This paper describes Texas Instruments new concepts in automated testing and cold probe technology as they apply to volume production.

  18. Depth of magnetic basement in Iran based on fractal spectral analysis of aeromagnetic data

    Science.gov (United States)

    Teknik, Vahid; Ghods, Abdolreza

    2017-06-01

    To estimate the shape of sedimentary basins, a critical parameter in hydrocarbon exploration, we calculated the depth of magnetic basement by applying a fractal spectral method to the aeromagnetic map of Iran. The depth of magnetic basement is a close proxy for the shape of sedimentary basins provided that igneous basement is strongly magnetized relative to the overlying sediments and there is no interbedding magnetic layer in the sediments. The shape of the power spectrum of magnetic anomalies is sensitive to the depth of magnetic basement, the thickness of the magnetic layer, the fractal parameter of magnetization and the size of the window used for the calculation of the power spectrum. Using a suite of synthetic tests, we have shown that the estimation of the depth of magnetic basement of up to 20 km is not very sensitive to the often unknown fractal parameter and thus the spectral method is a reliable tool to calculate the depth of magnetic basement. The depth of magnetic basement is in the range of 7-16 km in the Zagros, east Alborz, Tabas, Jazmurian and Makran regions, showing a close correlation with depths estimated from the maximum thickness of stratigraphic columns. We have also found new sedimentary basins in Bostan Abad, Bijar and south of Orumiyeh Lake. The significant depth of the magnetic basement in the Makran, Jazmurain depression, southeast Caspian Sea, Tabas, Great Kavir, south of Orumiyeh Lake, Bostan Abad and Bijar sedimentary basins makes them future prospects for hydrocarbon explorations. The depth of magnetic basement is strongly reduced over the Neyriz and Kermanshah Ophiolites, but it does not show any meaningful correlation with other outcrops of ophiolitic rocks in Iran.

  19. 111In-labeled nonspecific immunoglobulin scanning in the detection of focal infection

    International Nuclear Information System (INIS)

    Rubin, R.H.; Fischman, A.J.; Callahan, R.J.; Khaw, B.A.; Keech, F.; Ahmad, M.; Wilkinson, R.; Strauss, H.W.

    1989-01-01

    We performed radionuclide scanning after the intravenous injection of human IgG labeled with indium-111 in 128 patients with suspected focal sites of inflammation. Localization of 111In-labeled IgG correlated with clinical findings in 51 infected patients (21 with abdominal or pelvic infections, 11 with intravascular infections, 7 with pulmonary infections, and 12 with skeletal infections). Infecting organisms included gram-positive bacteria, gram-negative bacteria, Pneumocystis carinii, Mycoplasma pneumoniae, and Candida albicans. No focal localization of 111In-labeled IgG was observed in 63 patients without infection. There were five false negative results, and nine results were unusable. Serial scans were carried out in eight patients: continued localization correctly predicted relapse in six, and the absence of localization indicated resolution in two. To determine whether 111In-labeled IgG localization was specific for inflammation, we studied 16 patients with cancer. Focal localization occurred in 13 of these patients (5 with melanomas, 5 with gynecologic cancers, and 1 each with lymphoma, prostate cancer, and malignant fibrous histiocytoma). No localization was seen in patients with renal or colon cancer or metastatic medullary carcinoma of the thyroid. We conclude that 111In-labeled IgG imaging is effective for the detection of focal infection and that serial scans may be useful in assessing therapeutic efficacy. This technique may also be helpful in the evaluation of certain cancers

  20. Focal adhesive arachnoiditis of the spinal cord: Imaging diagnosis and surgical resolution

    Directory of Open Access Journals (Sweden)

    Hiroki Morisako

    2010-01-01

    Full Text Available Background: Although adhesive arachnoiditis of the spinal cord can cause progressive symptoms associated with syringomyelia or myelomalacia, its surgical resolution based on the imaging diagnosis is not well characterized. This study aims to describe the use of imaging for the diagnosis of focal adhesive arachnoiditis of the spinal cord and its surgical resolution using microsurgical arachnoidolysis. Materials and Methods: Four consecutive patients with symptomatic syringomyelia or myelomalacia caused by focal adhesive arachnoiditis underwent microsurgical arachnoidolysis. Comprehensive imaging evaluation using constructive interference in steady-state (CISS magnetic resonance imaging (MRI or myelographic MR imaging using true fast imaging with steady-state precession (TrueFISP sequences was included before surgery to determine the surgical indication. Results: In all four patients a focal adhesion was identified at the cervical or thoracic level of the spinal cord, a consequence of infection or trauma. Three patients showed modest or minor improvement in neurological function, and one patient was unchanged after surgery. The syringomyelia or myelomalacia resolved after surgery and no recurrence was noted within the follow-up period, which ranged from 5 months to 30 months. Conclusions: MRI diagnosis of focal adhesive arachnoiditis is critical to determine the surgical indication. Microsurgical arachnoidolysis appears to be a straightforward method for stabilizing the progressive symptoms, though the procedure is technically demanding.