WorldWideScience

Sample records for maxillary complete denture

  1. Light weight hollow maxillary complete denture: A case series

    Directory of Open Access Journals (Sweden)

    Laxman Singh Kaira

    2012-01-01

    Full Text Available Retention, stability and support are the basic principles on which the success of a complete denture relies on. The skill lies in applying these principles efficiently in critical situations. Residual ridge resorption occurs at a three times faster rate in mandibular arch than in the maxillary arch. The severely resorbed maxillary and mandibular edentulous arches that are narrow and constricted with increased interarch space provide decreased support, retention and stability. The consequent weight of the processed complete denture only compromises them further. The severely resorbed jaw can have various treatment options. Extreme resorption of the maxillary denture-bearing area may lead to problems with prosthetic rehabilitation. The advantage of a hollow maxillary or mandibular denture is the reduction of excessive weight of acrylic resin, which normally replaces lost alveolar ridge in the interridge space of the denture wearer. This clinical report describes two case reports of edentulous patients with resorbed ridges where a simplified technique of fabricating a light weight hollow maxillary complete denture was used for the preservation of denture bearing areas.

  2. A simple approach to hollow maxillary complete denture fabrication: An innovative technique

    Directory of Open Access Journals (Sweden)

    Kathleen Manuela D'souza

    2017-01-01

    Full Text Available A severely atrophic maxillary arch exhibits reduced denture bearing area and increased inter-ridge distance, thus, affecting retention of the complete denture. Such clinical situations necessitate the fabrication of a hollow complete denture to reduce the weight of the prosthesis and increase retention. This article describes a simple technique to fabricate a hollow maxillary complete denture using salt and thermoplastic poly (methyl methacrylate sheet. The vacuum-formed thermoplastic matrix regulates the quantity of salt and determines its placement in the unpolymerized denture base material during the denture packing stage. The matrix lining the hollow cavity also aids to reinforce the hollow denture base.

  3. Maxillary complete denture outcome with two-implant supported mandibular overdentures. A systematic review.

    Science.gov (United States)

    Rutkunas, Vygandas; Mizutani, Hiroshi; Peciuliene, Vytaute; Bendinskaite, Ruta; Linkevicius, Tomas

    2008-01-01

    Research data regarding maxillary complete denture outcome with two-implant supported mandibular overdentures are not consistent. Considering multiple publications on implant supported mandibular overdentures, it was decided to summarize currently present evidence on the maxillary complete dentures opposed by implant-supported mandibular overdentures, and analyze factors that could potentially influence the outcomes. The articles from 1985 to 2007 related to the topic were identified in the online MEDLINE/Pubmed and other databases and manually. Primary articles were scanned, and irrelevant studies were excluded from the further review process. Potentially relevant titles and abstracts were provisionally included for consideration on the basis of full text articles. Full text articles were obtained from on-line and printed sources. The data from the studies were extracted and reviewed. The study has failed to identify any prospective satisfying inclusion/exclusion criteria RCT reporting on maxillary bone resorption. The number of maxillary complete denture relining incidences per patient was constantly increasing during the 10-year period. Maxillary complete denture remake incidences comprised 16-33 % of the number of patients followed during the 10-year period. Comparing patient satisfaction with upper dentures at the baseline and after two years, no decrease in satisfaction was noticed. There is no evidence that maxillary ridge resorption is accelerated with certain types of two-implant supported mandibular overdenture attachments. Most common complication for the maxilla - prosthetic maintenance. There is a risk of decreased patient satisfaction with bar-supported mandibular overdenture. Further studies are needed to provide evidence for the maxillary complete denture outcome with two-implant supported mandibular overdentures.

  4. Accuracy of Digitally Fabricated Wax Denture Bases and Conventional Completed Complete Dentures

    Directory of Open Access Journals (Sweden)

    Bogna Stawarczyk

    2017-12-01

    Full Text Available The purpose of this investigation was to analyze the accuracy of digitally fabricated wax trial dentures and conventionally finalized complete dentures in comparison to a surface tessellation language (STL-dataset. A generated data set for the denture bases and the tooth sockets was used, converted into STL-format, and saved as reference. Five mandibular and 5 maxillary denture bases were milled from wax blanks and denture teeth were waxed into their tooth sockets. Each complete denture was checked on fit, waxed onto the dental cast, and digitized using an optical laboratory scanning device. The complete dentures were completed conventionally using the injection method, finished, and scanned. The resulting STL-datasets were exported into the three-dimensional (3D software GOM Inspect. Each of the 5 mandibular and 5 maxillary complete dentures was aligned with the STL- and the wax trial denture dataset. Alignment was performed based on a best-fit algorithm. A three-dimensional analysis of the spatial divergences in x-, y- and z-axes was performed by the 3D software and visualized in a color-coded illustration. The mean positive and negative deviations between the datasets were calculated automatically. In a direct comparison between maxillary wax trial dentures and complete dentures, complete dentures showed higher deviations from the STL-dataset than the wax trial dentures. The deviations occurred in the area of the teeth as well as in the distal area of the denture bases. In contrast, the highest deviations in both the mandibular wax trial dentures and the mandibular complete dentures were observed in the distal area. The complete dentures showed higher deviations on the occlusal surfaces of the teeth compared to the wax dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM-fabricated wax dentures exhibited fewer deviations from the STL-reference than the complete dentures. The deviations were significantly greater in the

  5. Rehabilitation of maxillary arch with attachment-retained mesh-reinforced single complete denture

    Science.gov (United States)

    Vamsi Krishna, C H; Rao, A Kaleshwar; Sekhar, N Chandra; Shastry, Y Mahadev

    2014-01-01

    Fabrication of conventional complete dentures was one of the most commonly advised treatment options to mange edentulous patients since many years. One of the commonly encountered challenging tasks in prosthodontics is a clinical situation in which patients have maxillary completely edentulous arches opposing mandibular natural dentition. This situation can be effectively managed by retaining some of the natural teeth as overdenture abutments. Tooth supported overdenture retained by attachments will improve retention, support and stability, and reduces rate of ridge resorption along with psychological benefits to the patients by providing tactile sensation. The present case report describes management of patients with edentulous maxillary arch opposing natural mandibular dentition-rehabilitated attachment-retained mesh-reinforced overdenture. PMID:24574522

  6. Rehabilitation of maxillary arch with attachment-retained mesh-reinforced single complete denture.

    Science.gov (United States)

    Vamsi Krishna, C H; Rao, A Kaleshwar; Sekhar, N Chandra; Shastry, Y Mahadev

    2014-02-26

    Fabrication of conventional complete dentures was one of the most commonly advised treatment options to mange edentulous patients since many years. One of the commonly encountered challenging tasks in prosthodontics is a clinical situation in which patients have maxillary completely edentulous arches opposing mandibular natural dentition. This situation can be effectively managed by retaining some of the natural teeth as overdenture abutments. Tooth supported overdenture retained by attachments will improve retention, support and stability, and reduces rate of ridge resorption along with psychological benefits to the patients by providing tactile sensation. The present case report describes management of patients with edentulous maxillary arch opposing natural mandibular dentition-rehabilitated attachment-retained mesh-reinforced overdenture.

  7. Efficacy of denture adhesives in maxillary dentures using gnathodynamometry: a comparative study.

    Science.gov (United States)

    Polyzois, Gregory; Lagouvardos, Panagiotis; Frangou, Maria; Stefaniotis, Theodoros

    2011-07-01

    The purpose of this study was to investigate the effect of four commercially available denture adhesives on the incisal and premolar dislodgement forces of maxillary complete dentures by using an electronic and disposable gnathodynamometer and compare the measured incisal forces for differences. This study was conducted with 12 complete maxillary denture wearers. Four commercially available denture adhesives Super Corega(®), Corega Ultra(®), Super Corega Powder(®) and Fittydent Cationic(®) were investigated. Testing protocol and sequence included baseline measurements without adhesives (control) for previous and new dentures and then replications of measurements with the four adhesives. Maximum dislodgement forces were recorded in two sites between central incisors and the left 2nd premolars by using an electronic and disposable gnathodynamometer. To estimate the effect of the different adhesives on the dislodgement forces, data were analyzed by a 2- and 3-way ANOVA, while for estimating the agreement of the two devices a Bland-Altman and Mountain plots were used. ANOVAs indicated significant differences between adhesives (p adhesives increase the denture dislodgement forces, but with differences among them. The two devices do not highly agree with each other, but each one alone is useful in estimating dislodgement forces in clinical practice and research.

  8. Speech intelligibility enhancement after maxillary denture treatment and its impact on quality of life.

    Science.gov (United States)

    Knipfer, Christian; Riemann, Max; Bocklet, Tobias; Noeth, Elmar; Schuster, Maria; Sokol, Biljana; Eitner, Stephan; Nkenke, Emeka; Stelzle, Florian

    2014-01-01

    Tooth loss and its prosthetic rehabilitation significantly affect speech intelligibility. However, little is known about the influence of speech deficiencies on oral health-related quality of life (OHRQoL). The aim of this study was to investigate whether speech intelligibility enhancement through prosthetic rehabilitation significantly influences OHRQoL in patients wearing complete maxillary dentures. Speech intelligibility by means of an automatic speech recognition system (ASR) was prospectively evaluated and compared with subjectively assessed Oral Health Impact Profile (OHIP) scores. Speech was recorded in 28 edentulous patients 1 week prior to the fabrication of new complete maxillary dentures and 6 months thereafter. Speech intelligibility was computed based on the word accuracy (WA) by means of an ASR and compared with a matched control group. One week before and 6 months after rehabilitation, patients assessed themselves for OHRQoL. Speech intelligibility improved significantly after 6 months. Subjects reported a significantly higher OHRQoL after maxillary rehabilitation with complete dentures. No significant correlation was found between the OHIP sum score or its subscales to the WA. Speech intelligibility enhancement achieved through the fabrication of new complete maxillary dentures might not be in the forefront of the patients' perception of their quality of life. For the improvement of OHRQoL in patients wearing complete maxillary dentures, food intake and mastication as well as freedom from pain play a more prominent role.

  9. A comparative analysis of salivary factors and maxillary denture retention in different arch forms: An in vivo study

    Directory of Open Access Journals (Sweden)

    Abhishek Shekhar

    2018-01-01

    Conclusions: Complete denture acts as a mechanical stimulant thus increasing flow rate and pH immediately after complete denture insertion. Density, total protein, and viscosity of saliva decreased after complete denture insertion which may be due to increase in water content of saliva. The retention of maxillary complete denture does not seem to depend on the rate of change of the salivary factors, before and after complete denture insertion. Total basal surface area and maxillary denture retention values were highest in square arch form and least in tapered arch form.

  10. Three dimensional changes in maxillary complete dentures immersed in water for seven days after polymerization

    Directory of Open Access Journals (Sweden)

    Shinsuke Sadamori

    2008-03-01

    Full Text Available The purpose of this study was to investigate the three dimensional changes in the fitting surface and artificial teeth of maxillary complete dentures which were fabricated using two different polymerizing processes: heat polymerization (HP and microwave polymerization (MP, after immersion in water for seven days. The amount of distortion in the molar region of the alveolar ridge was significantly different between HP and MP. However, the overall distortion of the dentures polymerized using both methods was similar. The distortion due to immersion in water for seven days compensated for the polymerization distortion, but the amount of distortion was very slight.

  11. Successful Fitting of a Complete Maxillary Denture in a Patient with Severe Alzheimer’s Disease Complicated by Oral Dyskinesia

    Directory of Open Access Journals (Sweden)

    Hiromitsu Morita

    2016-01-01

    Full Text Available There is an increasing population of elderly patients suffering from Alzheimer’s disease (AD, the most common form of dementia. In dentistry, a critical problem associated with these patients is the use of a new denture, as AD patients often refuse dental management and are disturbed by minor changes in their oral environment. Some AD patients have further complications associated with oral dyskinesia, a movement disorder that can make dental management difficult, including the stability of a complete denture. In this case, we successfully fitted a complete maxillary denture using modified bilateral balanced occlusion after multiple tooth extractions under intravenous sedation in a 66-year-old woman with severe AD complicated by oral dyskinesia. Following treatment, her appetite and food intake greatly improved. Providing a well-fitting complete denture applied by modified bilateral balanced occlusion, which removes lateral interference using zero-degree artificial teeth for movement disorder of the jaw in patients with severe AD complicated by oral dyskinesia, helps improve oral function.

  12. Adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by selective laser melting technique.

    Science.gov (United States)

    Ye, Ye; Jiao, Ting; Zhu, Jiarui; Sun, Jian

    2018-01-24

    The purpose of the study was to evaluate the adaptation and micro-structure of Co-Cr alloy maxillary complete denture base plates fabricated by the selective laser melting (SLM) technique. Twenty pairs of edentulous casts were randomly and evenly divided into two groups, and manufacturing of the Co-Cr alloy maxillary complete denture base was conducted either by the SLM technique or by the conventional method. The base-cast sets were transversally sectioned into three sections at the distal canines, mesial of the first molars and the posterior palatal zone. The gap between the metal base and cast was measured in these three sections with a stereoscopic microscope, and the data were analysed using t tests. A total of five specimens of 5 mm diameter were fabricated with the Co-Cr alloy by SLM and the traditional casting technology. A scanning electron microscope (SEM) was used to evaluate the differences in microstructure between these specimens. There was no statistical difference between the three sections in all four groups (P > 0.05). At the region of the canines, the clearance value for the SLM Co-Cr alloy group was larger than that of the conventional method group (P  0.05). The SLM Co-Cr alloy has a denser microstructure behaviour and less casting defect than the cast Co-Cr alloy. The SLM technique showed initial feasibility for the manufacture of dental bases of complete dentures, but large sample studies are needed to prove its reliability in clinical applications. The mechanical properties and microstructure of the denture frameworks prepared by selective laser melting indicate that these dentures are appropriate for clinical use.

  13. Influence of Palatal Coverage and Implant Distribution on Denture Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Tomita, Akiko; Mizuno, Yoko; Maeda, Yoshinobu

    2016-01-01

    As maxillary implant overdentures are being increasingly used in clinical practice, prosthodontic complications related to these dentures are also reported more often. The purpose of this study was to examine the influence of palatal coverage and implant distribution on the shear strain of maxillary implant overdentures. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar areas was fabricated. Two kinds of experimental overdentures, with and without palatal coverage, were also fabricated, and two strain gauges were attached at the midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain in each denture was compared by analysis of variance (P = .05). In all situations, the shear strain in palateless dentures was significantly higher than in dentures with palate on both sides (P overdentures exhibited much higher strain than overdentures with palate regardless of the implant distribution; this may cause more prosthodontic and implant complications. The most favorable configuration to prevent complications in maxillary implant overdentures was palatal coverage that was supported by more than four widely distributed implants.

  14. The effectiveness of chemical denture cleansers and ultrasonic device in biofilm removal from complete dentures

    Directory of Open Access Journals (Sweden)

    Patrícia Costa Cruz

    2011-12-01

    Full Text Available Adequate denture hygiene can prevent and treat infection in edentulous patients. They are usually elderly and have difficulty for brushing their teeth. OBJECTIVE: This study evaluated the efficacy of complete denture biofilm removal using chemical (alkaline peroxide-effervescent tablets, mechanical (ultrasonic and combined (association of the effervescent and ultrasonic methods. MATERIAL AND METHODS: Eighty complete denture wearers participated in the experiment for 21 days. They were distributed into 4 groups (n=20: (1 Brushing with water (Control; (2 Effervescent tablets (Corega Tabs; (3 Ultrasonic device (Ultrasonic Cleaner, model 2840 D; (4 Association of effervescent tablets and ultrasonic device. All groups brushed their dentures with a specific brush (Bitufo and water, 3 times a day, before applying their treatments. Denture biofilm was collected at baseline and after 21 days. To quantify the biofilm, the internal surfaces of the maxillary complete dentures were stained and photographed at 45º. The photographs were processed and the areas (total internal surface stained with biofilm quantified (Image Tool 2.02. The percentage of the biofilm was calculated by the ratio between the biofilm area multiplied by 100 and the total area of the internal surface of the maxillary complete denture. RESULTS: The Kruskal-Wallis test was used for comparison among groups followed by the Dunn multiple-comparison test. All tests were performed respecting a significance level of 0.05. Significant difference was found among the treatments (KW=21.18; P<0.001, the mean ranks for the treatments and results for Dunn multiple comparison test were: Control (60.9; Chemical (37.2; Mechanical (35.2 and Combined (29.1. CONCLUSION: The experimental methods were equally effective regarding the ability to remove biofilm and were superior to the control method (brushing with water. Immersion in alkaline peroxide and ultrasonic vibration can be used as auxiliary agents

  15. Different types of antagonists modify the outcome of complete denture renewal.

    Science.gov (United States)

    Berteretche, Marie Violaine; Frot, Amélie; Woda, Alain; Pereira, Bruno; Hennequin, Martine

    2015-01-01

    The effect of renewing removable dentures on masticatory function was evaluated according to the occlusion offered by different types of mandibular arches. Twenty-eight patients with complete maxillary dentures were subdivided into three groups in terms of mandibular dentition type: dentate, partial denture, and complete denture. The participants were observed before and 8 weeks after maxillary denture renewal. The mandibular denture was also renewed in the partial and complete denture groups. The participants masticated carrots, peanuts, and three model foods of different hardnesses. The particle size distribution of the boluses obtained from natural foods was characterized by the median particle size (d50) in relation to the masticatory normative indicator (MNI). Chewing time (CT), number of chewing cycles (CC), and chewing frequency (CF) were video recorded. A self-assessment questionnaire for oral health-related quality of life (Geriatric Oral Health Assessment Index [GOHAI]) was used. Statistical analyses were carried out with a mixed model. Renewal of the dentures decreased d50 (P < .001). The number of participants with d50 values above the MNI cutoff decreased from 12 to 2 after renewal. Renewal induced an increase in mean CF while chewing model foods (P < .001). With all foods, renewal tended to affect CT, CC, and CF differently among the three groups (statistically significant renewal Å~ group interactions). The GOHAI score increased significantly for all groups. Denture renewal improves masticatory function. The complete denture group benefited least from renewal; the dentate group benefited most. This study confirmed the usefulness of denture renewal for improving functions and oral health- related quality of life.

  16. [Anterior guidance in complete dentures].

    Science.gov (United States)

    Dubreuil, J; Trevelo, A

    1990-01-01

    Although the anterior guidance in complete dentures is not really a guide, the arrangement of the anterior maxillary and mandibular prosthetic teeth, defines a propulsive line called the virtual anterior guidance, a part from the cinematic criterias. The influence of this guide on cuspal movement is superior, in all mandibular points, to the influence of the condylar pathway. If this line is not respected, the practitioner may have to do excessive grindings during occlusal adjustments.

  17. Oral health-related quality of life of edentulous patients after complete dentures relining

    Directory of Open Access Journals (Sweden)

    Krunić Nebojša

    2015-01-01

    Full Text Available Background/Aim. Tooth loss affects oral health-related life quality. More than a third of edentulous patients are not fully satisfied with their complete dentures and mainly complain of insufficient stability, retention, and pain during mastication. Solving the problem may include relining by materials that are based on silicone or acrylic. The aim of this study was to determine the level of patients’ satisfaction before and after relining upper dentures with soft and rigid liners. Methods. The patients (n = 24 were divided into two study groups. Maxillary denture relining of the first group of patients was performed with hard acrylic based resins while in the second group of patients complete denture was relined with a silicone-based soft liner. They were asked the questions from the specifically adapted the Oral Health Impact Profile Questionnaire for edentulous patients before and three months after relining dentures. Results. After relining the patients showed a higher degree of satisfaction with their dentures in all the tested domains (masticatory function, psychological discomfort, social disability and retention and hygiene. The patients with soft denture relines were more satisfied. Conclusion. Relining of maxillary complete dentures significantly positively impacts the quality of life of patients in all the tested domains (masticatory function, psychological discomfort, social disability, pain and oral hygiene. Better results were achieved using a silicone-based soft liner, which recommends it as the material of choice for relining dentures.

  18. [Study on retention and stability of linear occlusal complete dentures].

    Science.gov (United States)

    Zhang, Ping; Xu, Jun

    2003-01-01

    To learn retention and stability of linear occlusal complete dentures by investigating the subjective feelings of patient and the value of retention force. Static retention forces of maxillary and mandibular dentures were measured for 25 patients wearing linear occlusal dentures by using Hz-1 retention dynamometer. The subjective feelings of patients in functional state were gained simultaneously through questionnaire. Linear occlusal dentures demonstrate good retention in static and dynamic state. Among patients with severe resorption of residual ridge (RRR), mandibular linear occlusal dentures (shown good retentive subjective feelings) demonstrate significantly smaller retention force than those with slight or medium degree of RRR. There is no correlation between the subjective feelings and the values of retention forces of mandibular dentures. The subjective feelings of patients wearing new linear occlusal dentures are much better than that of old anatomic occlusal dentures. Linear occlusal dentures improve the performances of dentures by enhancing their stability during mastication movement.

  19. Effects of Reinforcement on Denture Strain in Maxillary Implant Overdentures: An In Vitro Study Under Various Implant Configurations.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Maxillary implant overdentures are often designed without palatal coverage to maximize wearer comfort. Although palateless dentures have been reported to be less rigid than conventional dentures, and require reinforcement to prevent complications, there is little documentation about the effects of such reinforcement. The purpose of this study was to examine the effects of reinforcement on the strain on maxillary implant overdentures supported by implants in a variety of configurations. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar area was fabricated. Five types of experimental overdentures, with and without reinforcement, were fabricated, and two strain gauges were attached at the anterior midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain on the denture was measured. The measurements were compared using the Kruskal-Wallis test (P = .05). On both the labial and palatal sides, the strain on the palateless dentures with reinforcement was significantly lower than the strain on palateless dentures without reinforcement in all implant configurations (P overdenture with residual ridge reinforcement and a palatal bar could reduce the strain in the anterior midline to almost the same level as a denture with palatal coverage. This type of reinforcement may prevent prosthetic and implant complications.

  20. A study to evaluate the location and frequency of denture-related ulcerations and postinsertion adjustments in complete denture patients

    Directory of Open Access Journals (Sweden)

    Saurabh Jain

    2017-01-01

    Full Text Available Background and Aims: Removable complete denture is one of the most common treatment modalities for completely edentulous patients. After denture insertion, patient very often faces problems with the denture even after complete care is taken during fabrication procedure. Most common complaint is traumatic ulcers. The present study aimed to locate the most common areas of ulcerations due to complete dentures, how frequently they occur and how many times patient visits for adjustment after insertion of complete denture. Materials and Methods: Two hundred and twenty-one patients were selected and were delivered complete dentures. Dentures were fabricated for all the patients. Each step of denture fabrication was controlled and guided by a prosthodontist. After placement of dentures, patients were evaluated at every recall visit and their dentures were adjusted. All the details of each visit (area of ulceration and number of visits were recorded in a self-designed format. Descriptive statistical analysis was done using SPSS version 13 software. Chi-squared test was used to evaluate the correlation between mucosal injuries and postinsertion day and the relationship between lesions, patient age, and patient gender. Results: All the 221 patients required denture adjustment due to mucosal injuries. No significant difference was found between denture-related injuries between males and females. Injuries related to mandibular dentures were significantly higher than those related to maxillary dentures. In mandible, the most common area of mucosal injury is posterior one-third of alveololingual sulcus; while in maxilla, the most common area of mucosal injury is labial frenum. Conclusion: Postinsertion adjustments are an important aspect of rehabilitating patient with complete dentures. Most of the denture-related injuries were in limiting areas. Proper border molding techniques, accurate secondary impressions, and use of pressure indicating paste during

  1. Fabrication of titanium alloy frameworks for complete dentures by selective laser melting.

    Science.gov (United States)

    Kanazawa, Manabu; Iwaki, Maiko; Minakuchi, Shunsuke; Nomura, Naoyuki

    2014-12-01

    Casting difficulties have led to the limited use of titanium in dental prostheses. The selective laser melting system was recently developed to fabricate biomedical components from titanium alloys. However, the fabrication of a titanium alloy framework for a maxillary complete denture by selective laser melting has not yet been investigated. The purpose of the study was to fabricate thin titanium alloy frameworks for a maxillary complete denture with a selective laser melting system and to evaluate their hardness and microstructure. A cast of an edentulous maxilla was scanned with a dental 3-dimensional cone-beam computed tomography system, and standard triangulation language data were produced with the DICOM Viewer (Digital Imaging and Communications in Medicine). Two types of metal frameworks for complete dentures were designed with 3-dimensional computer-aided design software. Two titanium alloy frameworks, SLM-1 and SLM-2, were fabricated from these designs with the selective laser melting system. Plate-shaped specimens were cut from the central flat region of SLM-1, SLM-2, and as-cast Ti-6Al-4V (As-cast). Vickers hardness testing, optical microscopy, and x-ray diffraction measurements were performed. Thin titanium alloy frameworks for maxillary complete dentures could be fabricated by selective laser melting. The hardness values for SLM-1 and SLM-2 were higher than that for the as-cast specimen. Optical microscopy images of the SLM-1 and SLM-2 microstructure showed that the specimens did not exhibit pores, indicating that dense frameworks were successfully obtained with the selective laser melting process. In the x-ray diffraction patterns, only peaks associated with the α phase were observed for SLM-1 and SLM-2. In addition, the lattice parameters for SLM-1 and SLM-2 were slightly larger than those for the as-cast specimen. The mechanical properties and microstructure of the denture frameworks prepared by selective laser melting indicate that these dentures

  2. Comparison of digital surface displacements of maxillary dentures based on noninvasive anatomic landmarks.

    Science.gov (United States)

    Norvell, Nicholas G; Korioth, Tom V; Cagna, David R; Versluis, Antheunis

    2018-02-08

    Artificial markers called fiducials are commonly used to orient digitized surfaces for analysis. However, when these markers are tangible and placed in the region of interest, they may alter surface topography and influence data analysis. The purpose of this in vitro study was to apply a modified digital surface fitting method based on anatomic landmarks to evaluate denture accuracy and to use 2 different denture processing techniques to evaluate the method. The goal was to noninvasively measure and describe any surface differences in denture processing techniques at the intaglio and denture tooth levels. Twenty standardized maxillary complete dentures were waxed on standardized edentulous casts and processed by using acrylic resin compression (COM, n=10) and injection molding (INJ, n=10) methods. Digital scans were recorded of the anatomic surface of the cast, the intaglio and cameo surfaces of the acrylic resin dentures, and the cameo surface of the wax dentures. Three anatomic fiducials were identified on denture intaglio and cast scans and 4 on the cameo surfaces of waxed and acrylic resin denture scans. These fiducials were then used to digitally align the anatomic with the processed intaglio surfaces and the waxed with the processed cameo surfaces. Surface displacements were compared among processed dentures expressed at specific points (9 tissue landmarks and 8 tooth landmarks). The accuracy of surface displacements was assessed by changes in the number and location of anatomic fiducials. The scanning precision and the intraobserver repeatability in the selection of dental landmarks were also determined. For each landmark, the spatial (x, y, and z) mean differences between the 2 processing techniques were calculated for the intaglio and the cameo surfaces and presented on each orthogonal plane. Statistical nonparametric comparison of these means was analyzed with the Mann-Whitney U test (α=.05). Benjamini-Hochberg corrections for multiple comparisons were

  3. A comparison of three dimensional change in maxillary complete dentures between conventional heat polymerizing and microwave polymerizing techniques

    Directory of Open Access Journals (Sweden)

    Shinsuke Sadamori

    2007-03-01

    Full Text Available The purpose of this study was to measure and compare two different polymerizing processes, heat polymerizing (HP and microwave polymerizing (MP, on the three dimensional changes in the fitting surface and artificial teeth of maxillary complete dentures. A threedimensional coordinate measurement system was used to record distortion of the specimens. The distortion of the fitting surface was measured from the reference plane on the fitting side from which a coordinate system was set, and the movement of the artificial teeth and the distortion of the polished surface was measured from the reference plane of the artificial tooth side, from which a coordinate system was set. It was clearly showed that various distortions of denture specimens after polymerization process can be measured with this three-coordinate measuring machine. The study showed that the overall distortion of the fitting surface in HP specimens was shown to be larger than in MP ones.

  4. Etiological factors correlated with temporomandibular disorder in complete denture wearers: a comparative analysis

    Directory of Open Access Journals (Sweden)

    Ricardo Alexandre Zavanelli

    2009-01-01

    Full Text Available Objective: The aim of this study was to make a comparative evaluation of the prevalence of temporomandibular disorder in complete denturewearers, with regard to the etiological factors, such as gender, age, and complete dentures clinical conditions, according to the anamnestic(Ai and clinical (Di dysfunction index, developed by Helkimo.Methods: The randomized sample was composed of 90 institutionalized patients and bimaxillary complete denture wearers, with a mean ageof 67.2 years, who were included in this study. The collected data were tabulated and the Kruskal-Wallis and Chi-square statistical tests were applied, at the level of significance of 5% (p<0.05.Results: Statistically significant difference in the prevalence of temporomandibular disorder was observed with regard to the ages of the current complete dentures, free-way space, wear of the occlusal surfaces of the artificial teeth, and the conditions of retention and stability of the maxillary and mandibular complete dentures, according to both the indexes. Conclusion: The patients who wore complete dentures in adequate clinical conditions presented fewer signs and symptoms of temporomandibular disorder than the patients who wore complete dentures in poor clinical conditions.

  5. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA.

    Science.gov (United States)

    Qamheya, Ala Hassan A; Yeniyol, Sinem; Arısan, Volkan

    2015-01-01

    Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC) material in teeth construction to rehabilitate a complete denture wearer patient.

  6. Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA

    Directory of Open Access Journals (Sweden)

    Ala Hassan A. Qamheya

    2015-01-01

    Full Text Available Many people have life-long problems with their dentures, such as difficulties with speaking and eating, loose denture, and sore mouth syndrome. The evolution of dental implant supported prosthesis gives these patients normal healthy life for their functional and esthetic advantages. This case report presents the fabrication of maxillary implant supported hybrid prosthesis by using Nanofilled Composite (NFC material in teeth construction to rehabilitate a complete denture wearer patient.

  7. Effect of Attachment Type on Denture Strain in Maxillary Implant Overdentures: Part 1. Overdenture with Palate.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    This study examined the effects of attachments on strain in maxillary implant overdentures supported by two or four implants. A maxillary edentulous model with implants inserted into anterior, premolar, and molar areas was fabricated, and three types of unsplinted attachments-ball, locator, and magnet-were set on the implants distributed under various conditions. Maxillary experimental dentures were fabricated, and two strain gauges were attached at the anterior midline on the labial and palatal sides. A vertical occlusal load of 98 N was applied and shear strain of the dentures was measured. On both sides, magnet attachments resulted in the lowest shear strain, while ball attachments resulted in the highest shear strain under most conditions. However, differences in shear strain among the three attachment types were not significant when supported by four implants, especially molar implants. Shear strain of the maxillary implant overdenture was lowest when using magnet attachments. Magnet attachments mounted on four implants are recommended to prevent denture complications when using maxillary implant overdentures.

  8. Effect of three investing materials on tooth movement during flasking procedure for complete denture construction.

    Science.gov (United States)

    Salloum, Alaa'a M

    2016-01-01

    Tooth movement has been shown to occur during and after the processing of complete dentures. An understanding of this phenomenon may permit one to construct functional complete dentures that require less occlusal adjustment in the articulator and in the patient's mouth. The purpose of this study was to examine the effects of three different investing methods on tooth movement occurring during the processing of simulated maxillary complete dentures. Forty-five similar maxillary dentures were made using heat-polymerized acrylic resin, and assigned randomly to three experimental groups (n = 15 each) according to investing method: plaster-plaster-plaster (P-P-P), plaster-stone-stone (P-S-S), and plaster-mix (P-M). Specimens in all experimental groups were compression molded with denture base resin. Transverse interincisor (I-I) and intermolar (M-M) distances, and anteroposterior incisor-molar (LI-LM and RI-RM) distances, were measured with digital calipers at the wax denture stage (pre-polymerization) and after denture decasting (post-polymerization). Analysis of variance and Tukey's test were used to compare the results. M-M, LI-LM, and RI-RM movement was significantly greater in the P-P-P group than in the P-S-S and P-M groups; no significant difference in I-I movement was observed among groups. Transverse movement along M-M and I-I was significantly greater than anteroposterior movement in the P-P-P group; no significant difference among measurements was observed in the other two groups. The study results indicate that the use of dental stone or a 50:50 mixture of plaster and stone for investing of dentures is an important factor in efforts to control the magnitude of tooth movement.

  9. Restoration of facial symmetry in a patient with bell palsy using a modified maxillary complete denture: a case report.

    Science.gov (United States)

    Bagchi, Gautam; Nath, Dilip Kumar

    2012-01-01

    Permanent facial paralysis can be devastating for a patient. Modern society's emphasis on appearance and physical beauty contributes to this problem and often leads to isolation of patients embarrassed by their appearance. Lagophthalmos with ocular exposure, loss of oral competence with resultant drooling, alar collapse with nasal airway obstruction, and difficulties with mastication and speech production are all potential consequences of facial paralysis. Affected patients are confronted with both a cosmetic defect and the functional deficits associated with loss of facial nerve function. In this case history report, a modified maxillary complete denture permitted a patient with Bell palsy to carry on daily activities with minimal facial distortion, pain, speech difficulty, and associated emotional trauma.

  10. The effect of denture stability, occlusion, oral hygiene and smoking on denture-induced stomatitis

    International Nuclear Information System (INIS)

    Nimri, Gadeer Mukatash

    2008-01-01

    This longitudinal clinical investigation was undertaken to find out the effect of denture wearing habit (day versus day and night), denture hygiene and cigarette smoking habit on the frequency of denture induced stomatitis. Comparisons were made between 240 complete denture wearers, half of whom were asked to wear their dentures at the daytime only and the other half to wear the denture day and night. All these participants were male patients with a mean age of 57.6 years who had received maxillary complete acrylic dentures for the first time. Fifty percent of the samples were smokers. A standard method for examination of the mouth and denture construction, insertion and follow up were employed. Putative risk factors (denture wearing habits, denture hygiene and smoking) were investigated. Subjects were recalled 12 months after insertion to examine the quality of the denture and the condition of the maxillary mucosa. No significant correlation was found between deterioration of stability or occlusion and type of habitual use of the dentures (P > 0.05). Fourteen percent of the cases reported with inflamed maxillary mucosa. Deterioration of retention or occlusion separately showed no correlation with the condition of the mucosa. However, associated deterioration of both stability and occlusion proved to be significantly correlated with the occurrence of denture stomatitis (P < 0.05). Denture stomatitis was significantly more frequently with subjects wearing their dentures overnight compared with those who removed them (P < 0.05). A significant correlation was also found between cigarette smoking, poor oral hygiene and the presence of denture induced stomatitis (P < 0.05). Nocturnal denture wearing habit, deficient oral and denture hygiene, and cigarette smoking are all important predisposing factors to denture-induced stomatitis, however, none of these factors was the sole cause of mucosal inflammation. (author)

  11. EVALUATION OF MAXILLARY BONE DIMENSIONS IN SPECIFIC AREAS FOR REMOVABLE DENTURES

    Directory of Open Access Journals (Sweden)

    Dobromira Shopova

    2017-05-01

    Full Text Available Background: The removable prosthetics is a big part of Prosthetic Dentistry. The prosthetic field is very important for successful treatment with partial or complete dentures. Maxillary bone is covered with soft tissues, but its anatomy is essential for retention, chewing stability and comfort of the patients. Purpose: The study’s aim was to evaluate the dimensions of maxillary bone in specific zones for removable dentures. Methods: Sixteen craniums were measured in 10 different zones. It was used an Electronic Digital Caliper 0-150 mm. Results: Consistently were applied F-test and Welch t-test for equality of variance and group’s comparison mean, respectively. The spread of the data was described by calculating range and standard deviation. The estimated value of range was highest in the FI-A1P, followed by FI-AC and FI-A2P. The smallest amplitude was established in the TM-PP and SNA. The estimated value of standard deviation was 2,57/2,51 in FI-AC zone, 2,46/2,59 in FI-A1P zone and a few smaller 2,08/2,13 in FI-A2P zone. The lowest values were in TM-PP and SNA areas. Conclusion: Tuber maxillae and Spina nasalis anterior have stable dimensions. The areas of canine and premolars are varied, because the zone is tasked by chewing function.

  12. A clinical evaluation denture adhesives used by patients with xerostomia.

    Science.gov (United States)

    Bogucki, Zdzislaw A; Napadlek, Piotr; Dabrowa, Tomasz

    2015-02-01

    The purpose of study was to analyze the participants' opinions concerning the effectiveness of 6 denture adhesives (DA). The study group included 60 participants. Criteria for selecting the patients were as follows: reduced retention and stabilization of maxillary complete dentures and xerostomia. These features were evaluated on basis of clinical examination and standard sialometry tests (u-SFR). Retention of maxillary dentures was scored by modified Kapur index before application of DA. All participants were divided randomly into 6 groups regarding the use of the 6 DA during a 6-month period. After this time, participants completed an HRQL questionnaire. DA noticeably improved retention and stabilization of maxillary complete dentures. DA in the glue form had the best retention effectiveness in participants with xerostomia. These materials are difficult to clean from the denture base. The data are presented in tables and figures. The results of the study collected positive influence of adhesives on retention of dentures in xerostomia patients. The cleaning dentures and denture bearing tissues was difficult. DA help in the use of prostheses, but it is also necessary for the treatment of the causes and symptoms of xerostomia.

  13. Masticatory performance of complete denture wearers after using two adhesives: a crossover randomized clinical trial.

    Science.gov (United States)

    de Oliveira Junior, Norberto Martins; Rodriguez, Larissa Santana; Mendoza Marin, Danny Omar; Paleari, André Gustavo; Pero, Ana Carolina; Compagnoni, Marco Antonio

    2014-11-01

    Masticatory performance analysis of conventional complete denture wearers who use denture adhesives is scarce in the dental literature. The purpose of this study was to assess the effect of the use of 2 denture adhesives on the masticatory performance of conventional complete denture wearers by means of a crossover study. Forty individuals who were edentulous received new maxillary and mandibular complete dentures, and, after an adaptation period, were submitted to masticatory performance analysis without denture adhesive (control). The participants were randomly divided and assigned to 2 protocols: protocol 1, denture adhesive 1 (Ultra Corega cream tasteless) use during the first 15 days, followed by no use of denture adhesive over the next 15 days (washout), and then use of denture adhesive 2 (Ultra Corega powder tasteless) for 15 days; protocol 2, denture adhesive 2 (Ultra Corega powder tasteless) use during the first 15 days, followed by no use of denture adhesive during the next 15 days (washout), and then use of denture adhesive 1 (Ultra Corega cream tasteless) for 15 days. The masticatory performance was assessed immediately after the use of denture adhesive by means of the sieve method, in which participants were instructed to deliberately chew 5 almonds for 20 chewing strokes. Masticatory performance was calculated by the weight of comminuted material that passed through the sieves. Data were analyzed by a 1-way ANOVA for paired samples and the multiple comparison of means by using the Bonferroni test (α=.05). A significant increase in masticatory performance was noted after using the Ultra Corega cream (mean, 32.6%) and Ultra Corega powder (mean, 31.2%) when compared with the control group (mean, 19.8%) (Padhesives evaluated. The use of denture adhesive improved the masticatory performance of conventional complete denture wearers. No difference was found in masticatory performance with the use of cream or powder denture adhesive. Copyright © 2014

  14. Quantitative Estimation of Yeast on Maxillary Denture in Patients with Denture Stomatitis and the Effect of Chlorhexidine Gluconate in Reduction of Yeast

    Directory of Open Access Journals (Sweden)

    Jaykumar R Gade

    2011-01-01

    Full Text Available Denture stomatitis is a condition associated with wearing of a denture. The predisposing factor leading to denture stomatitis could be poor oral hygiene, ill-fitting denture and relief areas. Around 30 patients with denture stomatitis were advised to rinse with chlorhexidine gluconate mouthwash for 14 days and were directed to immerse the upper denture in the chlorhexidine solution for 8 hours. The samples were collected by scraping maxillary denture in saline at three intervals, prior to, at the end of 24 hours and after 14 days of treatment, then were inoculated and quantitative estimation of the yeast growth on Sabouraud′s dextrose agar plate was done. It was observed that after a period of 14 days, there was a reduction in the growth of yeast and also improvement in the clinical picture of the oral mucosa

  15. The attitude of complete denture wearers towards denture adhesives in Istanbul

    NARCIS (Netherlands)

    Ozcan, M.; Kulak, Y.; Arikan, A.; Silahtar, E.

    2004-01-01

    The purpose of using denture adhesives is to subjectively benefit denture-wearers with improved fit and comfort of their dentures and to improve their chewing ability and confidence. The purpose of this study was to investigate the approach and thought of complete denture wearers to denture

  16. Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures.

    Science.gov (United States)

    Al-Fouzan, Afnan F; Al-Mejrad, Lamya A; Albarrag, Ahmed M

    2017-10-01

    The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure ( P CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

  17. Finite element analysis and clinical complications in mandibular implant-overdentures opposing maxillary dentures.

    Science.gov (United States)

    Khuder, Tameem; Yunus, Norsiah; Sulaiman, Eshamsul; Dabbagh, Ali

    2017-11-01

    Denture fracture is a common clinical complication caused by improper material selection, design, or fabrication technique. This study aimed to investigate the effect of two attachment systems on fracture risk of the implant-overdentures (IOD) via finite element analysis (FEA), using the force distributions obtained from patients' occlusal analyses and to compare the obtained results with the clinical complications associated with these attachments. A three-dimensional jaw model comprised of the edentulous bones was constructed. Three types of mandibular prostheses including complete denture (CD) (model LCD), IOD with Locator attachment (model LID-L), and IOD with telescopic attachment (model LID-T), as well as a maxillary CD (model UCD) were assembled. The vertical occlusal forces at anterior and posterior quadrants were obtained from the patients wearing mandibular CDs or IODs. The FEA results were further compared with the mechanical failures of different prostheses observed at patient recalls. In overall, the fracture risk of mandibular prostheses was lower than the maxillary compartments. The UCD opposing LCD underwent higher strains than that opposing LID-L and LID-T, which was mostly concentrated at the anterior mid-palatal polished surface. On the other hand, LID-L showed the lowest strain, followed by LID-T, and LCD. The obtained results were consistent with the clinical complications observed in the patient recalls. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Hinged and sectional complete dentures for restricted mouth opening: A case report and review

    Directory of Open Access Journals (Sweden)

    Aditi Sharma

    2013-01-01

    Full Text Available Restricted mouth opening is a definite prosthodontic hindrance to carry out treatment successfully. Restricted mouth opening can be due to many reasons such as microstomia, oral submucous fibrosis, some genetic disorder, and as a result of some surgical treatment. In the past, various techniques for prosthetic rehabilitation of limited oral opening have been tried such as surgeries, use of dynamic opening devices, magnetic devices, and modification of denture design. Here we present; a simplified technique and simple design for fabrication of maxillary hinged and mandibular hinged and sectional complete denture for a patient with restricted mouth opening due to oral submucous fibrosis.

  19. Effect of Occlusal Scheme on the Pressure Distribution of Complete Denture Supporting Tissues: An In Vitro Study.

    Science.gov (United States)

    Madalli, Poornima; Murali, C R; Subhas, Sambit; Garg, Surbhi; Shahi, Prinka; Parasher, Pragati

    2015-01-01

    The complete denture teeth arrangement that gives maximum denture stability, comfort, esthetics, and function have been studied since several years. Many occlusal schemes have been advised in which the lingualized occlusion, balanced occlusion, and monoplane occlusion are advocated most popularly. The purpose of this study was to compare the pressure values on the supporting tissue using three diff erent posterior occlusal schemes: Balanced occlusion, lingualized occlusion, and monoplane occlusion in simulated dentures. The simulators used in this study, composed of the maxillary, and mandibular clear heat cure acrylic resin edentulous models. Pressures on the supporting structure under the complete denture were measured using eight strain gauges placed on the model surface on the buccal and lingual slopes of the ridges on the molar and pre-molar region. Pressure on the supporting structure was measured and signals from the sensors were amplifi ed and recorded by the multi-channel electronic strain indicator. The mean pressure which was obtained at each measurement point was compared by one-way ANOVA test. Overall monoplane occlusion had lesser pressure values compared to completely balanced and lingualized occlusal scheme. Lingualized occlusal scheme was found to transfer stresses from working side to non-working side to stabilize the mandibular denture.

  20. Zygomatic implant-retained fixed complete denture for an elderly patient.

    Science.gov (United States)

    Baig, Mirza Rustum; Rajan, Gunaseelan; Yunus, Norsiah

    2012-06-01

    Dental rehabilitation of a completely edentulous geriatric patient has always been a challenge to the clinician, especially in treating those with higher expectations and demands. Treatment duration and the amount of residual alveolar bone available are often important considerations when planning for dental implant-based fixed treatment for these patients. With the introduction of zygomatic implants, a graftless alternative solution has emerged for deficient maxillary bone with provision for immediate loading. This article describes the treatment of a completely edentulous elderly patient using zygomatic implants in conjunction with conventional implants. The implants were immediately loaded using a definitive acrylic resin fixed denture reinforced with a cast metal framework, to provide function and aesthetics. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  1. Remedy for Repeated Implant Retained Denture Fracture-A Challenging Case Report

    Science.gov (United States)

    Reddy M, Ramu; Metta, Kiran Kumar; Charry N, Sudheer; B, Chittaranjan

    2014-01-01

    The most common site of fracture in a maxillary or a mandibular complete denture is along an anteroposterior line that coincides with the labial notch in in the denture which used to provide the frenum relief. Osseointegrated implants have been a boon to the patients who are completelly edentulous and are not satisfied with the conventional removable complete denture approach.Implant supported dentures have proven to provide superior retention and support for removable complete dentures. Nevertheless, fracture of the denture bases is a common complication of implant-supported mandibular overlay dentures,ecspecially when the artificial denture is opposing natural dentition. This article describes and illustrates a method of reinforcing implant-supported mandibular overdentures to overcome this problem. PMID:25584333

  2. A 2D panoramic surgical stent imaging: Complete arch mandibular implant fixed prosthesis along with bar supported maxillary over denture

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar Singhal

    2017-01-01

    Full Text Available Successful rehabilitation of a patient should restore function, esthetic, and speech by prosthesis. Treatment modalities vary from patient to patient. Semi-precision attachments and implants offer several advantages over the traditional approach. The aim and objective of this report was to assess a case of a 55-year-old female patient who had lost all her teeth, except maxillary canines #13 and #23 and with severe bone loss in the mandible. Tooth-supported bar attachment was planned for maxilla, and a total of five dental implants were placed in the mandible using a flapless approach aided by radiographic gutta-percha surgical stents over panoramic two-dimensional imaging. Customized, radiographic stents help for the placement of implant in the view of paralleling and flapless surgery, completely. An immediate loading protocol is adopted as from day of the surgery to 6 weeks along with implant supported full arch fixed dentures after 4 months. The outcome of the treatment was impressive, and the patient gave a positive response with superb esthetics and functions.

  3. Two-Implant-Supported Mandibular Overdentures: Do Clinical Denture Quality and Inter-Implant Distance Affect Patient Satisfaction?

    Science.gov (United States)

    Alfadda, Sara A; Al Amri, Mohammad D; Al-Ohali, Amal; Al-Hakami, Arwa; Al-Madhi, Noura

    To investigate the following three null hypotheses in patients rehabilitated with a mandibular overdenture supported by two unsplinted implants: (1) patient satisfaction is not related to the clinical quality of the dentures; (2) inter-implant distance (IID) has no effect on the clinical quality of the dentures; and (3) IID does not influence patient satisfaction. Forty edentulous patients who were rehabilitated with a two-implant-supported mandibular overdenture participated in the study. Independent investigators evaluated the dentures on the basis of five clinical criteria using the validated Denture Quality Evaluation Form, and the patients completed the validated Denture Satisfaction Scale. Irreversible hydrocolloid impressions of the mandible were made and poured immediately in die stone. The IID was measured by adapting an orthodontic wire to the mandibular alveolar ridge crest, extending from the center of one implant to the center of the other. Spearman correlation analyses were used to identify possible correlations, with a significance level set at P overdenture and of the maxillary conventional complete denture was significantly related to satisfaction (r = 0.389 and r = 0.44, respectively). Significant associations were found between the mandibular stability items and satisfaction with both maxillary and mandibular dentures. The stability of the maxillary denture was significantly associated with patient satisfaction with mandibular denture retention, stability, and comfort. None of the 12 denture satisfaction items were significantly associated with IID. Similarly, IID did not have an effect on the quality of either denture in terms of retention, stability, or occlusion. Denture stability was the feature that had the most influence on patient satisfaction with the mandibular overdenture and with the maxillary conventional denture. IID had no effect on the clinical quality of either denture and did not influence patient satisfaction.

  4. Elderly complete denture wearers: a social approach to tooth loss.

    Science.gov (United States)

    Papadaki, Eftychia; Anastassiadou, Vassiliki

    2012-06-01

    To correlate emotional reactions to tooth loss with denture satisfaction attributes in elderly complete denture wearers. Total tooth loss is a serious life event, and poor oral health has an impact on daily life. Edentulism treated by rehabilitation with dentures can have a positive effect on patients' self-image and social behaviour. A group of 80 edentulous subjects undergoing routine prosthetic care in a Greek Department of Prosthetic Dentistry were interviewed using two structured questionnaires. The first questionnaire explored reactions to tooth loss, whereas the second measured their subjective experience of complete dentures. The responses to both questionnaires were compared using the statistical package SPSS v.17. The results showed significant correlation between aspects of tooth loss experience and complete denture satisfaction. Despite the fact that a substantial proportion of patients were satisfied with their complete dentures, some patients experienced increased social and psychological problems related to their edentulousness and the wearing of complete dentures. The aesthetic and functional aspects of complete dentures affected both patients' social behaviour and self-confidence. Total tooth loss was not only reflected in patient's social behaviour and self-image, but it had a complex and multifaceted impact on satisfaction from complete dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  5. Reinforcing effect of glass-fiber mesh on complete dentures in a test model with a simulated oral mucosa.

    Science.gov (United States)

    Yu, Sang-Hui; Oh, Seunghan; Cho, Hye-Won; Bae, Ji-Myung

    2017-11-01

    Studies that evaluated the strength of complete dentures reinforced with glass-fiber mesh or metal mesh on a cast with a simulated oral mucosa are lacking. The purpose of this in vitro study was to compare the mechanical properties of maxillary complete dentures reinforced with glass-fiber mesh with those of metal mesh in a new test model, using a simulated oral mucosa. Complete dentures reinforced with 2 types of glass-fiber mesh, SES mesh (SES) and glass cloth (GC) and metal mesh (metal) were fabricated. Complete dentures without any reinforcement were prepared as a control (n=10). The complete dentures were located on a cast with a simulated oral mucosa, and a load was applied on the posterior artificial teeth bilaterally. The fracture load, elastic modulus, and toughness of a complete denture were measured using a universal testing machine at a crosshead speed of 5 mm/min. The fracture load and elastic modulus were analyzed using 1-way analysis of variance, and the toughness was analyzed with the Kruskal-Wallis test (α=.05). The Tukey multiple range test was used as a post hoc test. The fracture load and toughness of the SES group was significantly higher than that of the metal and control groups (P<.05) but not significantly different from that of the GC group. The elastic modulus of the metal group was significantly higher than that of the control group (P<.05), and no significant differences were observed in the SES and GC groups. Compared with the control group, the fracture load and toughness of the SES and GC groups were higher, while those of the metal group were not significantly different. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Design of Complete Dentures by Adopting CAD Developed for Fixed Prostheses.

    Science.gov (United States)

    Li, Yanfeng; Han, Weili; Cao, Jing; Iv, Yuan; Zhang, Yue; Han, Yishi; Shen, Yi; Ma, Zheng; Liu, Huanyue

    2018-02-01

    The demand for complete dentures is expected to increase worldwide, but complete dentures are mainly designed and fabricated manually involving a broad series of clinical and laboratory procedures. Therefore, the quality of complete dentures largely depends on the skills of the dentist and technician, leading to difficulty in quality control. Computer-aided design and manufacturing (CAD/CAM) has been used to design and fabricate various dental restorations including dental inlays, veneers, crowns, partial crowns, and fixed partial dentures (FPDs). It has been envisioned that the application of CAD/CAM technology could reduce intensive clinical/laboratory work for the fabrication of complete dentures; however, CAD/CAM is seldom used to fabricate complete dentures due to the lack of suitable CAD software to design virtual complete dentures although the CAM techniques are in a much advanced stage. Here we report the successful design of virtual complete dentures using CAD software of 3Shape Dental System 2012, which was developed for designing fixed prostheses instead of complete dentures. Our results demonstrated that complete dentures could be successfully designed by the combination of two modeling processes, single coping and full anatomical FPD, available in the 3Shape Dental System 2012. © 2016 by the American College of Prosthodontists.

  7. Impact of mandibular conventional denture and overdenture on quality of life and masticatory efficiency

    Directory of Open Access Journals (Sweden)

    Rachel Gomes CARDOSO

    Full Text Available Abstract The aim of this non-randomized controlled clinical trial was to evaluate the oral health-related quality of life and masticatory efficiency of patients rehabilitated with mandibular two-implant overdentures with immediate loading or conventional dentures. Fifty completely edentulous patients wearing bimaxillary conventional dentures, for at least one year, were recruited. The patients were then assigned to either two treatment groups: mandibular overdentures supported by two implants with bar-clip system and a maxillary conventional denture (n = 25, and new maxillary and mandibular conventional complete dentures (n = 25. Masticatory efficiency and oral health-related quality of life were assessed before and 3 months after denture insertion. The Brazilian version of OHIP-Edent questionnaire was used to assess the oral health-related quality of life. Masticatory efficiency was evaluated with chewing capsules through a colorimetric method. The results revealed fewer oral health–related quality of life problems in patients wearing mandibular two-implant overdentures compared to the conventional dentures group. In addition, the implant overdenture group presented statistically significant improvement in masticatory efficiency (p = 0.001. There was no correlation between masticatory efficiency and OHIP in the implant group (p > 0.05, however a correlation was found in the conventional denture group (p < 0.05. Therefore, these short-term results suggest that mandibular overdenture retained by 2 implants with immediate loading combined with maxillary conventional dentures provide better masticatory efficiency and oral health–related quality of life than mandibular conventional dentures.

  8. Trial of an experimental castor oil solution for cleaning dentures.

    Science.gov (United States)

    Andrade, Ingrid Machado de; Andrade, Kelly Machado de; Pisani, Marina Xavier; Silva-Lovato, Cláudia Helena; de Souza, Raphael Freitas; Paranhos, Helena de Freitas Oliveira

    2014-01-01

    Denture hygiene is essential because denture biofilm is involved in oral infections and systemic diseases. Although there are chemical agents available on the market, none of them have ideal properties and research on such products is still necessary. The aim of this study was to evaluate the efficacy of a castor bean (Ricinus communis)-based solution for removing denture biofilm, compared to two traditional products (sodium hypochlorite and alkaline peroxide). Fifty maxillary complete denture wearers were instructed to brush their dentures after meals and to immerse their dentures once a day in the following solutions: Saline (20 min; control), Polident alkaline peroxide (3 min), NaOCl (20 min) and 2% castor oil solution (20 min). Participants used each solution for a period of 7 consecutive days, according to a random sequence. After each period, the internal surfaces of maxillary complete dentures were stained with a disclosing solution (1% neutral red), photographed and the disclosed biofilm was quantified with the aid of specific software. The influence of treatments on results was verified by the Friedman test (α=0.05). Tested solutions presented significant difference (Fr=51.67; pcastor oil presented intermediate results (median: 1.0% and 1.5%, respectively). It can be concluded that the castor oil solution tested in this study was comparable to alkaline peroxide in terms of efficiency in denture biofilm removal.

  9. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study.

    Science.gov (United States)

    Babu, Sumanth; Manjunath, Shaurya; Vajawat, Mayuri

    2016-01-01

    The aim of this in-vitro study was to assess the influence of shallow and deep palatal forms on the movement of teeth during the processing of complete denture prosthesis. Maxillary casts with shallow and deep palatal forms were selected and duplicated to make 10 casts of each palatal form. Base plates were constructed and teeth were arranged in their anatomic positions. Metal pins with true apex were placed on the central groove of the right and left first molars and one on the incisive papilla area as a reference point. Casts were scanned using i-CAT Vision Q 1.9 (i-CAT cone beam 3D dental imaging system by Imaging Sciences International, PA, USA), which has 360° rotational tomography. The distances between the apices of metallic pin inserts on the teeth and fitted point of reference were recorded in buccopalatal axes at waxed up stage, after deflasking, and after finishing and polishing. Results showed a statistically significant movement of teeth in shallow and deep palatal forms during all stages of complete denture processing. In shallow palatal form dentures, there was a significant tooth movement in palatal direction between Stages 1 and 2 (P ≤ 0.05) and buccal movement between Stages 2 and 3. In deep palatal form dentures, teeth showed a statistically significant (P ≤ 0.05) movement in buccal direction during all stages of denture processing. Teeth showed significant movement during processing of acrylic resin dentures. Overall, the movement of teeth in shallow palatal form dentures was in palatal direction, whereas in deep palatal form dentures, the movement of teeth was in buccal direction.

  10. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study

    Directory of Open Access Journals (Sweden)

    Sumanth Babu

    2016-01-01

    Full Text Available Aim: The aim of this in-vitro study was to assess the influence of shallow and deep palatal forms on the movement of teeth during the processing of complete denture prosthesis. Materials and Methods: Maxillary casts with shallow and deep palatal forms were selected and duplicated to make 10 casts of each palatal form. Base plates were constructed and teeth were arranged in their anatomic positions. Metal pins with true apex were placed on the central groove of the right and left first molars and one on the incisive papilla area as a reference point. Casts were scanned using i-CAT Vision Q 1.9 (i-CAT cone beam 3D dental imaging system by Imaging Sciences International, PA, USA, which has 360° rotational tomography. The distances between the apices of metallic pin inserts on the teeth and fitted point of reference were recorded in buccopalatal axes at waxed up stage, after deflasking, and after finishing and polishing. Results: Results showed a statistically significant movement of teeth in shallow and deep palatal forms during all stages of complete denture processing. In shallow palatal form dentures, there was a significant tooth movement in palatal direction between Stages 1 and 2 (P ≤ 0.05 and buccal movement between Stages 2 and 3. In deep palatal form dentures, teeth showed a statistically significant (P ≤ 0.05 movement in buccal direction during all stages of denture processing. Conclusion: Teeth showed significant movement during processing of acrylic resin dentures. Overall, the movement of teeth in shallow palatal form dentures was in palatal direction, whereas in deep palatal form dentures, the movement of teeth was in buccal direction.

  11. Functional Impressions in Complete Denture and Overdenture Treatment

    Directory of Open Access Journals (Sweden)

    Hrvoje Kršek

    2015-01-01

    Full Text Available Tooth loss can cause loss of occlusal, masticatory, esthetic, physiognomic, phonetic and psychosocial function of patients. The most frequently used treatment method of completely edentulous patients and patients with a small number of remaining teeth are complete dentures or overdentures. One of the most important clinical and laboratory procedures in their fabrication is functional impression taking. The aim of this paper was to present procedures of taking functional impressions in fabrication of complete dentures and overdentures, using standardized techniques and materials. An accurate functional impression together with other correctly performed clinical and laboratory procedures ensure good retention and stability of dentures, which is a precondition for restoring patients’ lost functions.

  12. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  13. Perception of Esthetic Impact of Smile Line in Complete Denture Wearers by Different Age Groups.

    Science.gov (United States)

    Pithon, Matheus Melo; Alves, Leandro Pereira; da Costa Prado, Matheus; Oliveira, Rener Leal; Costa, Matheus Souza Campos; da Silva Coqueiro, Raildo; Gusmão, João Milton Rocha; Santos, Rogério Lacerda

    2016-10-01

    To evaluate esthetic perceptions based on tooth exposure when smiling of patients wearing complete dentures by evaluators in different age groups. Alterations were made to a front view photograph of a smiling patient wearing complete maxillary and mandibular dentures. Alterations in the smile line were simulated to increase or decrease tooth exposure (increments of 0.5 mm). For this purpose, image manipulation software was used. After manipulation, images were printed on photo paper, attached to a questionnaire, and distributed to individuals in three age groups (n = 150). To evaluate the esthetic perception for each image, a visual analog scale was used, with 0 representing least attractive, 5 representing attractive, and 10 representing very attractive. Differences between examiners were analyzed using the Mann-Whitney test. All statistical analyses were performed with a degree of confidence of 95%. Two evaluators did not observe any differences between images. The images given the best and worst scores were E and O (alterations of 2 and 7 mm), respectively, in the 15- to 19-year-old group, B and O (alterations of 0.5 and 7 mm), respectively, in the 35- to 44-year-old group, and A and M (no alteration and 6 mm alteration), respectively, in the 65- to 74-year-old group. When the images were presented together (images 1 and 2), the unaltered image was selected by individuals of different age groups as the best, and the image with a change of 7 mm was selected as the worst. In this study, complete dental prostheses with smile lines that coincided with the cervical margins of the anterior teeth were the most acceptable. Less exposure of the maxillary teeth when smiling corresponded with decreased attractiveness. © 2015 by the American College of Prosthodontists.

  14. Effect of microwave cured acrylic resin on candidal growth in complete denture

    International Nuclear Information System (INIS)

    Rasmy, A.H.M.

    2009-01-01

    This study was conducted to evaluate the effect of heat-cured acrylic resin denture base and microwave-cured acrylic resin denture base on candidal growth . Seven completely edentulous male patients with on history of denture wearing participated in this study. all the selected patients were re-habilitated by mucosa supported complete dentures .The dentures were constructed from conventional heat-cured acrylic resin denture base following monoplane concept of occlusion. Before dismissing the patients and one month after denture insertion, salivary samples were collected according to oral rinse technique. one month resting period was allowed so as candidal count can reach to normal, then dentures were re based using microwave-cured acrylic denture base, before denture insertion and one month after denture insertion, salivary sample were collected before and one month following the same oral rinse technique.

  15. Attitudes and usage of denture adhesives by complete denture wearers: a survey in Greece and the Netherlands.

    NARCIS (Netherlands)

    Polyzois, G.L.; Baat, C. de

    2012-01-01

    OBJECTIVE: To explore whether there are differences in usage of and attitudes towards denture adhesives among patients in two countries. BACKGROUND: There are no multi-country surveys concerning usage of and attitudes towards denture adhesives from complete denture wearers. MATERIALS AND METHODS:

  16. Improvdent: Improving dentures for patient benefit. A crossover randomised clinical trial comparing impression materials for complete dentures

    Directory of Open Access Journals (Sweden)

    Gray Janine C

    2012-08-01

    Full Text Available Abstract Background According to the UK Adult Dental Health Survey (2009 15% of adults aged 65–74, 30% aged 75–84 and 47% aged >85 years are edentulous and require complete dentures. Patients’ quality of life and nutrition status are affected by poor dentures. The quality of the dental impression is the most important issue for improving the fit and comfort of new dentures. There is paucity of RCT evidence for which impression material is best for complete dentures construction. This study aims to compare two impression materials for effectiveness and cost effectiveness. Methods/Design IMPROVDENT is a double-blind crossover trial comparing the use of alginate and silicone, two commonly used denture impression materials, in terms of patient preference and cost-effectiveness. Eighty five edentulous patients will be recruited and provided with two sets of dentures, similar in all aspects except for the impression material used (alginate or silicone. Patients will try both sets of dentures for a two-week period, unadjusted, to become accustomed to the feel of the new dentures (habituation period. Patients will then wear each set of dentures for a period of 8 weeks (in random order during which time the dentures will be adjusted for optimum comfort. Finally, patients will be given both sets of dentures for a further two weeks to wear whichever denture they prefer (confirmation period. Patients will be asked about quality of life and to rate dentures on function and comfort at the end of each trial period and asked which set they prefer at the end of the habituation period (unadjusted denture preference and confirmation period (adjusted denture preference. A health economic evaluation will estimate incremental cost-effectiveness ratios of producing dentures from the two materials. A qualitative study will investigate the impact of dentures on behaviour and quality of life. Funding: IMPROVDENT is funded by NIHR RfPB (PB-PG-0408-16300. Discussion

  17. Attitudes and usage of denture adhesives by complete denture wearers: a survey in Greece and the Netherlands.

    Science.gov (United States)

    Polyzois, Gregory L; de Baat, Cees

    2012-06-01

    To explore whether there are differences in usage of and attitudes towards denture adhesives among patients in two countries. There are no multi-country surveys concerning usage of and attitudes towards denture adhesives from complete denture wearers. The survey took place in Greece and the Netherlands with a sample of 284 and 165 consecutive complete denture wearers, respectively, by using a 9-item prepared questionnaire. Statistical analysis relied on chi-square test at α = 0.05. In this survey, 26 and 20% of Greek and Dutch patients, respectively, had tried denture adhesive, but only 27% of them in Greece as well as in the Netherlands currently used it; 49% of the Greek and 45% of the Dutch participants rated the overall performance of adhesives as good. Between the two populations, no differences were identified in a majority of the research variables, except where 27% of Greeks answered that they did not know the existence of denture adhesives compared to none of the Dutch patients and when 90% of the Dutch contrary to 70% of Greeks reported that they did not need denture adhesives as they could manage their dentures well. The usage of and attitudes towards denture adhesives between the Greek and Dutch sample were similar with only two exceptions concerning the knowledge of existence and the need of using denture adhesives. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  18. A comparative study of retention of complete denture base with different types of posterior palatal seals – an in vivo study

    Directory of Open Access Journals (Sweden)

    Chandu GS

    2014-11-01

    Full Text Available GS Chandu,1 BS Hema,2 Harsh Mahajan,1 Antriksh Azad,2 Ipsita Sharma,3 Anurag Azad4 1Department of Prosthodontics, Rishiraj College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India; 2Department of Conservative Dentistry, Rishiraj College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India; 3Department of Oral Pathology, RKDF Dental college and Research centre, Bhopal, Madhya Pradesh, India; 4Department of Oral and Maxillofacial Surgery, Bhabha College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India Aim: To evaluate retention of complete denture base with different types of posterior palatal seals. Material and methods: Ten male patients between the age group of 50 years to 60 years were selected for the study. After the primary and secondary impressions were taken, five casts were made including a cast without posterior palatal seal, a cast with single bead posterior palatal seal, a cast with double bead posterior palatal seal, a cast with butterfly shaped posterior palatal seal, and a cast with posterior palatal seal with low fusing compound by functional method. Results: It was observed that retention increased up to 108% in the posterior palatal seal with low fusing compound with functional method and the posterior palatal seal that was obtained by using functional method provided greater retention than a denture base without posterior palatal seal. Conclusion: It was concluded that the incorporation of a posterior palatal seal is important for obtaining optimum retention of the maxillary complete denture. Keywords: posterior palatal seal, denture base, complete denture, functional method

  19. Conventional Complete Denture in Patients with Ectodermal Dysplasia

    Directory of Open Access Journals (Sweden)

    Larissa Soares Reis Vilanova

    2015-01-01

    Full Text Available Ectodermal dysplasia is described as heritable conditions that involve anomalies of structures derived from the ectoderm, including hypodontia. In the cases of edentulous young patients, who did not finish their craniofacial growth, treatment with conventional complete denture is a suitable alternative. The aim of this study was to report a case of mandibular edentulism treated with conventional complete denture in a thirteen-year-old patient diagnosed with hidrotic ectodermal dysplasia. Typical features, such as frontal bossing, depressed nasal bridge, protuberant lips, scarce hair, and brittle nails, were visualized during the extraoral examination. The intraoral inspection and radiographic analysis revealed oligodontia, dental malformation, and prolonged retention of deciduous teeth at maxilla and total edentulism at mandible. A conventional complete denture was planned and constructed following the same steps of technique as recommended in adults. Although this option is not a definitive treatment, the patient and his parents were satisfied with his improvement in chewing and speech, as well as with the aesthetic benefits.

  20. Evaluation of Prevalence of Oral Candidiasis in Patients Using Complete Denture Wears

    Directory of Open Access Journals (Sweden)

    P Tavakkol

    2001-06-01

    Full Text Available Denture stomatotos os a common problem of the denture wears, and its etiology is not clear from the literatures. Some studies show that the aetiology is candida albicans, while other reports point out the other agents including candida albicans. The present study was designed to evaluate the prevalence of oral candidiasis in patients using complete denture with different datas. 50 subjects all wearing complete denture participated in this study. The palatal mucosa was swabbed and swabs were cultured in Sabourauds medium containing 0.005% chloramphenicol then cultures were tested with common mycological lab tests. In 80% of patients oral candidiasis have been diagnosed. In the investigation a direct relation between the oral candidiasis and removal of denture at night, denture cleanliness, presence of any suction and symptoms of denture stomatitis was shown. No relation between the oral candidiasis and sex, smoking habit, succeptible disease, angular cheilitis; the recent condition of denture and the retention of denture were found. The findings of our investigation indicates that candida albicans is the causative agent of denture stomatitis while other factors such as denture cleanliness, removal of denture at night and presence of any suction may be considered as well.

  1. Unsplinted implants and teeth supporting maxillary removable partial dentures retained by telescopic crowns: a retrospective study with >6 years of follow-up.

    Science.gov (United States)

    Frisch, Eberhard; Ratka-Krüger, Petra; Wenz, Hans-Jürgen

    2015-09-01

    Data regarding tooth- and implant-supported maxillary removable partial dentures (TIRPDs) are scarce. The objective of this research was to perform a retrospective evaluation of the clinical long-term outcome of maxillary TIRPDs rigidly retained via telescopic crowns in patients undergoing supportive post-implant therapy (SIT). The inclusion criteria were met by 26 patients restored with maxillary TIRPDs between 1997 and 2011 in a private practice. Primary crowns (Marburg double crowns, MDCs) on teeth were cemented, whereas those on implants were screw-retained. Using patient records and data from a cross-sectional clinical examination in 2013, the survival rates of the teeth, implants and prostheses, together with the biological and technical complications, were analyzed. After 6.12 ± 3.80 (range: 2-16) years of loading, 23 non-smoking patients with 23 dentures supported by 60 implants and 66 teeth were available for assessment. Nine teeth (survival rate: 86.36%) were lost, whereas 1 implant (survival rate: 98.36%) failed because of peri-implantitis. Although 30 implants (50%) in 16 patients (69.57%) showed bleeding on probing (BOP+), no further peri-implantitis was observed. The mean peri-implant probing depth (PPD) was 3.68 ± 0.71 mm. All dentures were functional and required technical maintenance efforts amounting to 0.128 treatments per patient per year (T/P/Y). Within the limitations of this study, we conclude that TIRPDs retained via MDCs may represent a viable treatment option for patients with residual maxillary teeth. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Fabricating Complete Dentures with CAD/CAM and RP Technologies.

    Science.gov (United States)

    Bilgin, Mehmet Selim; Erdem, Ali; Aglarci, Osman Sami; Dilber, Erhan

    2015-06-01

    Two techological approaches for fabricating dentures; computer-aided design and computer-aided manufacturing (CAD/CAM) and rapid prototyping (RP), are combined with the conventional techniques of impression and jaw relation recording to determine their feasibility and applicability. Maxillary and mandibular edentulous jaw models were produced using silicone molds. After obtaining a gypsum working model, acrylic bases were crafted, and occlusal rims for each model were fabricated with previously determined standard vertical and centric relationships. The maxillary and mandibular relationships were recorded with guides. The occlusal rims were then scanned with a digital scanner. The alignment of the maxillary and mandibular teeth was verified. The teeth in each arch were fabricated in one piece, or set, either by CAM or RP. Conventional waxing and flasking was then performed for both methods. These techniques obviate a practitioner's need for technicians during design and provide the patient with an opportunity to participate in esthetic design with the dentist. In addition, CAD/CAM and RP reduce chair time; however, the materials and techniques need further improvements. Both CAD/CAM and RP techniques seem promising for reducing chair time and allowing the patient to participate in esthetics design. Furthermore, the one-set aligned artificial tooth design may increase the acrylic's durability. © 2015 by the American College of Prosthodontists.

  3. Clinical evaluation of three denture cushion adhesives by complete denture wearers.

    Science.gov (United States)

    Koronis, Spyros; Pizatos, Evangelos; Polyzois, Gregory; Lagouvardos, Panagiotis

    2012-06-01

    The aim of this study was the clinical evaluation of three denture cushion adhesives and whether the results were correlated to Kapur Index for denture-supporting tissues. Various types of denture adhesives are used among denture patients. However, information on the clinical behaviour of denture cushions is limited. Thirty edentulous patients had their denture-supporting tissues scored by Kapur Index and their old dentures replaced. They received three brands of denture cushion adhesives (Fittydent(®) , Protefix(®) and Seabond(®)) and were instructed to use them in a sequence according to the group they were randomly assigned to. Each brand of adhesive was used for 48 h on the lower denture according to the manufacturer's suggestions. After each brand was used, participants spent 24 h without applying any sort of adhesive. Finally, a questionnaire evaluating and comparing the performance of each brand was filled out. Denture adhesives generally improved patient satisfaction and masticatory ability, especially in participants with poor Kapur Index and those who reported a poor retention of their old dentures. Fittydent(®) was the most preferred adhesive, showing the best retention and the longest duration of its effect, but also reported as difficult to remove from the denture-bearing area. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  4. Expectations and final evaluation of complete dentures by patients, dentist and dental technician.

    Science.gov (United States)

    Marachlioglou, C R M Z; Dos Santos, J F F; Cunha, V P P; Marchini, Leonardo

    2010-07-01

    There is a poor association between the dentist's evaluation of denture quality and patients' satisfaction with their dentures. Possible differences between dental professionals and patients' expectations might help explain differences in outcome evaluations. This study compared scores given by a dentist, a dental technician and patients for their expectations before and their final evaluation after complete dentures treatment. Twenty completely edentulous patients, a prosthodontist and a dental technician provided scores for the expected aesthetic and functional results of their dentures based on a visual analogue scale at baseline. Post-treatment completion ratings were given after adjustments, by dentist and patients. The dental technician provided post-treatment completion ratings after completing the dentures. The patients had higher expectations than the dental technician and the dentist perceived for both aesthetic and function (P < 0.001). The patients also presented higher post-treatment completion ratings than the dental professionals perceived for final aesthetics (P = 0.016, Kendall's W = 0.207) and function (P = 0.002, Kendall's W = 0.303). Only the dentist presented a statistically significant difference between expectations (lower) and final (higher) outcomes for aesthetics (P = 0.017) and function (P = 0.003). There was no correlation between expectations and post-treatment completion ratings according to the patients' age. There was also no correlation between the patients' gender and expectation scores. Patients presented higher expectations regarding their dentures than dental professionals. The dentist believed that dentures would bring fewer benefits than patients did, but his perception of denture benefits post-treatment was significantly higher than his expectations.

  5. Removable denture-related oral mucosal lesions: descriptive clinical study

    Directory of Open Access Journals (Sweden)

    Gökçen Akçiçek

    2017-05-01

    Full Text Available Objective: The aim of this study was to investigate whether there was a relationship between removable denture-related oral mucosal lesions and denture type, and demographic characteristics. Materials and Method: The age, sex, denture type, systemic condition and medication use, presence of denture-related oral mucosal lesions (DROML, their locations and patients’ awareness of above mentioned lesions were recorded for 199 patients. Pearson chi-square test was used to analyse the relationship between the DROML and denture type, and demographic characteristics of the patients. Results: Among the patients included to the study, 122 (61.3% were female and 77 (38.7% were male. Ninety-six patients (48.2% exhibited DROML, whereas 103 patients (51.8% had no DROML. No relationship was detected between DROML and age, and sex (p>0.05. The most commonly detected DROML was denture stomatitis (34.7%. Denture stomatitis was significantly more frequently seen in partial denture wearers (p<0.05, while epulis fissuratum and flabby ridge were statistically more frequent in complete denture wearers (p<0.001. Traumatic ulcer was more frequently found in mandibular complete denture wearers (p<0.05, while epulis fissuratum and flabby ridge were significantly more common in maxillary complete denture wearers (p<0.001. Among the patients with DROML, 57.3% stated that they were unaware of these lesions. Conclusion: In this study sample, the rate of DROML was high in patients wearing removable dentures (48.2%, and more than half of the patients with DROML were not aware of these lesions. Upon these findings, it is considered that removable denture wearers should follow the denture usage instructions and should be informed about the importance of periodic controls.

  6. The lingualized occlusion of complete denture

    Institute of Scientific and Technical Information of China (English)

    BEN Wei-hong; Eleni Roumanas

    2008-01-01

    This article reviews the literatures dealing with the lingualized occlusion of complete denture including the origin,development and research. Lingualized occlusion is a valuable concept because many advantages of anatomic and nonanatomic occlusions are retained,satisfactory occlusion is easily obtained,balanced occlusion can be accomplished.

  7. [Gerontoprosthesis. Concept of rebuilding old complete dentures].

    Science.gov (United States)

    Marxkors, R; Mayer, K

    1990-04-01

    If aged patients who have been wearing their full dentures without complications so far, need further prothetic treatment, the dentist must not replace the old denture by a completely new one. It is better to rebuild it step by step. This demand is based on the following theses: --Nobody but the patient himself is able to perform functional movements. --Unless bite and occlusion are correct, patients are not able to perform accurate functional movements. --When bite and occlusion have been checked and, if necessary, improved, bases and alveolar ridges must be congruent.

  8. [Correlation of psychoemotional status and adaptation to complete dentures].

    Science.gov (United States)

    Barkan, I Yu; Stafeev, A A; Repin, V S

    2015-01-01

    Patients with full adentia are characterized by the formation of specific psycho-emotional status. Rational psychotherapeutic support of these patients largely determines the efficiency of dental prosthetic treatment. At the same time, the definition of mental and emotional status is not included in the diagnostic examination protocol. Considering the above the purpose of the study was to evaluate mental and emotional status of patients receiving complete dentures. Prosthetic rehabilitation of 30 patients with complete teeth loss was performed and clinical evaluation and evaluation of mental and emotional status were carried out before and after treatment. Patients with negative experiences of prosthetics showed a higher level of personal and situational anxiety. There was correlation of adaptation to removable dentures and the patient's personality traits. It is determined that emotional instability during treatment tends to decrease affecting the timing of adaptation to complete dentures. It is noted that patients with repeated prosthetics have earlier recovery of coordination ability of the masticatory muscles.

  9. Factors influencing patients’ satisfaction with complete dentures: a qualitative study.

    OpenAIRE

    Silva, Jessica de Cassia Motta; Departamento de Odontologia – Univ de Taubaté – Taubaté – SP – Brazil.; dos Santos, Jarbas Francisco Fernandes; Departamento de Odontologia – Univ de Taubaté – Taubaté – SP – Brazil.; Marchini, Leonardo; College of Dentistry – University of Iowa – Iowa City – IA – USA.

    2014-01-01

    Objective: The treatment most used worldwide for edentulism is conventional complete dentures, and the most important factor for the success of denture treatment seems to be patient satisfaction. The present study aims to use a qualitative approach to investigate factors that were previously associated with patient satisfaction with dentures by quantitative techniques (correlational studies). Material and methods: Twenty patients (12 women and 8 men, age 59-87) participated in open and semi-s...

  10. A Randomised Controlled Trial of complete denture impression materials

    Science.gov (United States)

    Hyde, T.P.; Craddock, H.L.; Gray, J.C.; Pavitt, S.H.; Hulme, C.; Godfrey, M.; Fernandez, C.; Navarro-Coy, N.; Dillon, S.; Wright, J.; Brown, S.; Dukanovic, G.; Brunton, P.A.

    2014-01-01

    Objectives There is continuing demand for non-implant prosthodontic treatment and yet there is a paucity of high quality Randomised Controlled Trial (RCT) evidence for best practice. The aim of this research was to provide evidence for best practice in prosthodontic impressions by comparing two impression materials in a double-blind, randomised, crossover, controlled, clinical trial. Methods Eighty-five patients were recruited, using published eligibility criteria, to the trial at Leeds Dental Institute, UK. Each patient received two sets of dentures; made using either alginate or silicone impressions. Randomisations determined the order of assessment and order of impressions. The primary outcome was patient blinded preference for unadjusted dentures. Secondary outcomes were patient preference for the adjusted dentures, rating of comfort, stability and chewing efficiency, experience of each impression, and an OHIP-EDENT questionnaire. Results Seventy-eight (91.8%) patients completed the primary assessment. 53(67.9%) patients preferred dentures made from silicone impressions while 14(17.9%) preferred alginate impressions. 4(5.1%) patients found both dentures equally satisfactory and 7 (9.0%) found both equally unsatisfactory. There was a 50% difference in preference rates (in favour of silicone) (95%CI 32.7–67.3%, p alginate as their material of choice for secondary impressions for complete dentures. Trial Registration: ISRCTN 01528038.

 This article forms part of a project for which the author (TPH) won the Senior Clinical Unilever Hatton Award of the International Assocation for Dental Research, Capetown, South Africa, June 2014. PMID:24995473

  11. Effect of Microwave Cured Acrylic Resin on Candidal Growth in Complete denture

    International Nuclear Information System (INIS)

    Rasmy, A.H.M.

    2009-01-01

    This study was conducted to evaluate the effect of heat-cured acrylic resin denture base and microwave-cured acrylic resin denture base on Candidal growth. Seven completely edentulous male patients with no history of denture wearing participated in this study. All the selected patients were re-habilitated by mucosa supported complete dentures. The dentures were constructed from conventional heat-cured acrylic resin denture base following monoplane concept of occlusion. Before dismissing the patients and one month after denture insertion, salivary samples were collected according to oral rinse technique. One month resting period was allowed so as Candidal count can reach to normal. Then dentures were re based using microwave-cured acrylic denture base, before denture insertion and one month after denture insertion, salivary sample were collected before and one month following the same oral rinse technique. In the oral rinse technique, the patients were instructed to rinse their mouths with 10 mL of sterile phosphate buffered saline for 60 seconds. The rinse was then expectorated into a universal container and immediately transported to the laboratory for concentration by centrifugation, then cultured on sabouraud's dextrose agar plates which were incubated at 37 degree C for 48 hours. Microscopic examination and germ tube test were carried out for laboratory investigations. In addition, the morphological features of the isolated Candida from the samples tested in this study, were investigated using the scanning electron microscope(SEM)

  12. Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes.

    Science.gov (United States)

    Bidra, Avinash S; Farrell, Kimberly; Burnham, David; Dhingra, Ajay; Taylor, Thomas D; Kuo, Chia-Ling

    2016-05-01

    Presently, no studies have evaluated clinical outcomes or patient-centered outcomes for complete dentures fabricated with computer-aided design and computer aided manufacturing (CAD/CAM) technology. The purpose of this prospective cohort pilot study was to evaluate the clinical and patient-centered outcomes for CAD/CAM monolithic dentures fabricated in 2 visits. Twenty participants with an existing set of maxillary complete dentures opposing either mandibular complete dentures or implant-retained overdentures that required replacement were recruited in this study. A 2-visit duplicate denture protocol was used to fabricate 40 arches of monolithic dentures with CAD/CAM technology. A 100-mm visual analog scale (VAS) instrument was then used to record 12 outcomes at baseline and at 1-year follow-up. Predetermined values were assigned to grade the VAS rating of each outcome as favorable (70.1-100) and unfavorable (≤70). Favorable ratings were sub-divided as excellent (90.1-100), good (80.1-90), and fair (70.1-80). The clinical outcomes were evaluated independently by 2 experienced prosthodontists at baseline and at 1-year follow-up. Patients evaluated the corresponding patient-centered outcomes during the same time intervals. Additional descriptive variables were also recorded. Each clinical and patient-centered outcome was summarized by medians and ranges. Differences in all ratings recorded at baseline and at 1 year were tested by 1-sided sign test (α=.05). Of 20 participants, 3 were lost to follow-up, and 3 were unsatisfied with the digital dentures and withdrew from the study. These 3 participants were considered treatment failures. Of the 14 remaining participants, 9 had implant-retained mandibular overdentures, and 5 had conventional mandibular complete dentures. For clinical outcomes, the 12 studied outcomes were favorably evaluated by the 2 prosthodontist judges at the 1-year follow-up. Evaluations showed minimal differences between baseline and 1 year. An

  13. The Effect of Two Types of Denture Adhesive on the Satisfaction Parameters of Complete Denture Wearers

    Directory of Open Access Journals (Sweden)

    Farzin M

    2017-09-01

    Full Text Available Statement of Problem: Patient satisfaction is highly influenced by the retention of the denture. In some instances using denture adhesives may help the patient to achieve this goal. Objectives: The purpose of this study was to evaluate the participants’ ’opinion concerning the effectiveness of two types of denture adhesives having the same composition (Fixative-powder, Protefix-cream. Materials and Methods: Forty healthy patients (25 Males and 15 Fe-males who visited the Department of Prosthodontics of Shiraz Dentistry School were selected. The oral cavity was examined and patients with oral ulcers, history of allergic reaction, severe xerostomia, red, white and/or red and white lesions were excluded. The subjects were instructed to receive a sequence of treatment protocols. All patients applied Fixative-powder on the dentures for seven days. The Participants were asked to fill a question-naire to include their opinion regarding the strength, biocompatibility, convenience and masticatory ability of the adhesive. On the next seven days, the patients were asked not to use the adhesives and they completed the same questionnaire again. Finally, all participants were asked to apply Protefix-cream on their dentures for a week followed by no cream applica-tion for another 7 days. These patients answered the same questionnaire and data were collected and analyzed using paired-samples t-test and Chi-square test. Result: Denture adhesives significantly improved the overall satisfaction level of the patients (p =0.01. When testing the fixative powder, the satis-faction score of the participants during the first week (powder application and the 2nd weak (no application was 19.95±3.76 and 26.2±2.82, respec-tively. The overall satisfaction rate of the patients using the Protefix adhe-sive was 19.35±5.48 in the third week (adhesive application and 25.85± 4.35 in the fourth week (no application. Conclusions: The study clarified that applying denture

  14. [Comparison of adaptation and microstructure of titanium upper complete denture base fabricated by selecting laser melting and electron beam melting].

    Science.gov (United States)

    Ye, Y; Xiong, Y Y; Zhu, J R; Sun, J

    2017-06-09

    Objective: To fabricate Ti alloy frameworks for a maxillary complete denture with three-dimensional printing (3DP) technique, such as selective laser melting (SLM) and electron beam melting (EBM), and to evaluate the microstructure of these frameworks and their adaptation to the die stone models. Methods: Thirty pairs of edentulous casts were divided into 3 groups randomly and equally. In each group, one of the three techniques (SLM, EBM, conventional technique) was used to fabricate Ti alloy frameworks. The base-cast sets were transversally sectioned into 3 sections at the distal of canines, mesial of first molars, and the posterior palatal zone. The gap between the metal base and cast was measured in the 3 sections. Stereoscopic microscope was used to measure the gap. Three pieces of specimens of 5 mm diameter were fabricated with Ti alloy by SLM, EBM and the traditional casting technology (as mentioned above). Scanning electron microscope (SEM) was used to evaluate the differences of microstructure among these specimens. Results: The gaps between the metal base and cast were (99.4±17.0), (98.2±26.1), and (99.6± 16.1) μm in conventional method; (99.4 ± 22.8), (83.1 ± 19.3), and (103.3 ± 13.8) μm in SLM technique; (248.3±70.3), (279.1±71.9), and (189.1±31.6) μm in EBM technique. There was no statistical difference in the value of gaps between SLM Ti alloy and conventional method Ti alloy group ( P> 0.05). There was statistical difference among EBM Ti alloy, conventional method Ti alloy and SLM Ti alloy group ( Palloy showed more uniform and compact microstructure than the cast Ti alloy and EBM Ti alloy did. Conclusions: SLM technique showed initial feasibility to manufacture the dental base of complete denture. The mechanical properties and microstructure of the denture frameworks prepared by SLM indicate that these dentures are appropriate for clinical use. EBM technique is inadequate to make a complete denture now.

  15. Complete Denture Impression Techniques Practiced by Private Dental Practitioners: A Survey

    OpenAIRE

    Kakatkar, Vinay R.

    2012-01-01

    Impression making is an important step in fabricating complete dentures. A survey to know the materials used and techniques practiced while recording complete denture impressions was conducted. It is disheartening to know that 33 % practitioners still use base plate custom trays to record final impressions. 8 % still use alginate for making final impressions. An acceptable technique for recording CD impressions is suggested.

  16. [Complete denture occlusion considered from occlusal contacts during mastication].

    Science.gov (United States)

    Suzuki, Tetsuya

    2004-12-01

    Few reports describe the functional superiority of full balanced occlusion to that of lingualized occlusion. Recently, a bilateral balanced scheme has been much more generally applied than a unilateral balanced scheme in lingualized occlusion as well as in full balanced occlusion. Occlusal contacts on the non-chewing side occur earlier than on the chewing side;in the order of second molar, first molar, and then premolars. The contact on the balancing side contributes to the prevention of denture dislocation and guidance from eccentric positions to the centric occlusal position during mastication. Therefore, bilateral balanced occlusion was shown to be effective for denture stability during mastication with complete dentures. Today's typical edentulous patients have greater mean age than in the past, and thus are seen with severe alveolar bone resorption, thin mucosa and sometimes abnormalities of the maxillomandibular relation. Their occlusal positions are often unstable and changeable after insertion of complete dentures. Because lingualized occlusion allows for easier accommodation and correction, lingualized occlusion is more suitable for such cases than full balanced occlusion, which requires a strict occlusal relationship. In light of the standard Japanese diet, there is some doubt about why lingualized occlusion might be suitable for Japanese edentulous patients in terms of the sense of mastication. A method of evaluating the sense of mastication needs to be established.

  17. The effect of a commercial probiotic drink on oral microbiota in healthy complete denture wearers

    Directory of Open Access Journals (Sweden)

    Justyna Sutula

    2012-10-01

    Full Text Available Background : It is acknowledged that oral and general health status declines with age. The global population of denture wearers is increasing, so is the incidence of denture biofilm-related problems, such as denture-associated stomatitis, aspiration pneumonia and malodour. It has been suggested that consumption of probiotic bacteria may improve oral health. However, the effects of probiotics on the oral microbiota of denture wearers have received little attention. Methods : The aim of this study was to investigate the effect of consumption of a commercial probiotic product (Yakult on microbiota of saliva, tongue and denture biofilm in healthy complete denture wearers. Eight healthy complete denture-wearing National Health Service (NHS patients undertook a 7-week trial comprising three phases: baseline; 4-week consumption of one bottle of Yakult per day, each containing a minimum 6.5×109 viable cells of Lactobacillus casei strain Shirota (LcS; 4-week washout period. The microbial viability and composition of saliva, tongue dorsum coating and denture biofilm were assessed using a range of solid selective and indicator media. Questionnaires were used to explore participants’ denture cleaning habits and impact of wearing dentures on their life quality and well-being [modified oral health impact profile (OHIP-14] prior to and after the study. Results : Seven volunteers (1 male, 6 females completed the trial. LcS temporarily colonised oral cavity and denture surface. There was no significant change in the viability of Streptococcus mutans, acidogenic microorganisms, total anaerobic species and Gram-negative obligate anaerobes between study phases. There was no obvious effect of LcS on occurrence and viability of Candida. Participants presented a good general knowledge of denture hygiene and their responses to OHIP-14 questionnaires improved after completing the study (p=0.16. Conclusion : It appeared that 4-week consumption of probiotic drink had

  18. The Role of New Removable Complete Dentures in Stimulated Salivary Flow and Taste Perception.

    Science.gov (United States)

    Tango, Rubens Nisie; Arata, Anelyse; Borges, Alexandre Luiz Souto; Costa, Anna K F; Pereira, Luciano Jose; Kaminagakura, Estela

    2018-04-01

    To evaluate the effect of replacement of inadequate complete dentures on salivary flow and taste perception in geriatric patients. Thirty-three patients, 13 males and 20 females, with a mean age of 64.4 years were submitted to stimulated and unstimulated salivary flow rate and salivary pH measurements, and sense of taste evaluation. Tests were performed 3 months before complete denture substitution and 3 weeks after denture insertion. The mean for unstimulated saliva (USS) was 2.1 ml before and 2.7 ml after replacement (p = 0.003). The mean volume of stimulated saliva was 6.3 ml before and 8.2 ml after replacement (p = 0.004). The pH mean of USS was 7.8 ± 0.44 before and 8.02 ± 0.41 after replacement (p = 0.005). No statistically significant difference was determined in the sense of taste before and 3 weeks after complete denture replacement. The replacement of inadequate complete dentures increases saliva flow; however, it does not improve taste perception. © 2016 by the American College of Prosthodontists.

  19. A 2-year report on maxillary and mandibular fixed partial dentures supported by Astra Tech dental implants. A comparison of 2 implants with different surface textures

    DEFF Research Database (Denmark)

    Karlsson, U; Gotfredsen, K; Olsson, C

    1998-01-01

    In 50 partially edentulous patients, 133 (48 maxillary; 85 mandibular) Astra Tech dental implants of 2 different surface textures (machined; TiO-blasted) were alternately installed, supporting 52 fixed partial dentures (FPDs). Before abutment connection 2 machined implants (1 mandibular; 1...

  20. Isolation of Candida species from the oral cavity and fingertips of complete denture wearers.

    Science.gov (United States)

    Nagaral, Suresh; Desai, Raviraj G; Kamble, Vikas; Patil, Anand Kumar G

    2014-11-01

    Wearing a dental prosthesis is known to increase oral candidal colonization and predispose the wearer to oral candidosis. Denture wearers frequently use fingers to take the prosthesis out of their mouth. Oral Candida, if present may contaminate wearer's finger. The objective of this study was to investigate the simultaneous candidal colonization of oral cavity and fingertips of complete denture wearers. A total of 25 apparently healthy male subjects who had worn complete dentures for at least 1 year were selected. Information about each patient's denture age, denture hygiene, handling, and wearing habits, and hand washing habits after denture handling were be obtained. Intraoral examination of all the patients was done. For microbiological examination samples were collected from the fingertip and oral rinse of each patient. Candida species were identified with use of germ tube test and commercially available yeast identification system. Data was statistically analyzed. Significance was set at p < 0.05. It was found that frequency of hand washing, denture handling and denture stomatitis with respect to fingertip candidal isolation was not statistically significant. But poor denture hygiene and denture stomatitis with respect to oral candidal colonization was statistically significant. Denture wearers with oral Candida had a higher prevalence of Candida contamination on their fingers. Patients with removable prostheses should be informed about the importance of proper prosthesis and personal hygiene and the possibility of microbial contamination of the hands and other parts of the body.

  1. The influence of resilient liner and clip attachments for bar-implant-retained mandibular overdentures on opposing maxillary ridge. A 5-year randomised clinical trial.

    Science.gov (United States)

    Elsyad, M A; Ashmawy, T M; Faramawy, A G

    2014-01-01

    This study aimed to compare the influence of resilient liner and clip attachments for bar-implant-retained mandibular overdentures on opposing maxillary ridge after 5 years of denture wearing. Thirty edentulous male patients (mean age 62·5 years) received two implants in the anterior mandible after being allocated into two equal groups using balanced randomisation. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I, GI) or silicone resilient liners (group II, GII). The prosthetic and soft tissue complications of the maxillary dentures were recorded 6 months (T6 m ), 1 year (T1), 3 years (T3) and 5 years (T5) after overdenture insertion. Traced rotational tomograms were used for measurements of maxillary alveolar bone loss. The proportional value between bone areas and areas of reference not subject to resorption was expressed as a ratio (R). Change in R immediately before (T0) and after 5 years (T5) of overdenture insertion was calculated. Maxillary denture relining times and frequency of flabby anterior maxillary ridge occurred significantly more often in GI compared with GII. The change of R in anterior part of maxilla was significantly higher than change of R in posterior part in both groups. GI showed significant resorption of anterior residual ridge compared with GII. Relining times and frequencies of flabby ridge were significantly correlated with change in R. Within the limitations of this study, resilient liner attachments for bar-implant-retained mandibular overdentures are associated with decreased resorption and flabbiness of maxillary anterior residual ridge and fewer maxillary denture relining times when compared with clip attachments. © 2013 John Wiley & Sons Ltd.

  2. Occlusal designs on masticatory ability and patient satisfaction with complete denture: a systematic review.

    Science.gov (United States)

    Zhao, Ke; Mai, Qing-Qing; Wang, Xiao-Dong; Yang, Wen; Zhao, Li

    2013-11-01

    To systematically review clinical outcomes of different occlusal designs of complete dentures. Using a various key words, an electronic search of clinical trials published in English and Chinese literature was performed from four databases: Medline/PubMed, EMBASE, Cochrane Library, and CBM. Furthermore, a manual searching of the relevant journals and the bibliographies of reviews was performed. General satisfaction, masticatory ability, retention, and stability were major criteria for the evaluation of the outcomes. Studies met these criteria were selected for a full-text reading. The whole processes were performed by two reviewers independently. This systematic review started with 1030 articles, which were finally narrowed down to seven, according to the inclusion criteria. The following occlusal designs were included and analyzed: anatomic occlusion, balanced occlusion, canine guidance occlusion, lingualized occlusion, monoplane occlusion, and bilateral-balanced and canine-guided design. Three of the seven studies showed that lingualized occlusion had ratings of higher patients' satisfaction than other occlusion designs. On the other hand, the canine-guided occlusion dentures demonstrated equal or better clinical performances than bilateral-balanced dentures. Because of the heterogeneity and bias of the studies, it was not possible to analyze the data statistically. Lingualized occlusion and canine-guided occlusion can be successfully applied in the fabrication of complete dentures. Canine guided occlusion has also been shown to be satisfactory. More well-controlled randomized trials are needed regarding canine-guided occlusion and the relationship between alveolar ridge resorption, different occlusal schemes and patient satisfaction. The conventional prosthodontic wisdom that complete dentures require a balanced occlusal design is not supported by the included literature. A suitable occlusal scheme would be a critical factor for a successful complete denture

  3. [Selection of occlusal scheme on the basis of pressure distribution on supporting structures under complete dentures].

    Science.gov (United States)

    Nagao, Kan; Kawano, Fumiaki; Ichikawa, Tetsuo

    2004-12-01

    In case of making complete dentures, we have to consider not only denture stability but also the restoration of aesthetics and function such as mastication and speech. However these are contradictory theoretically from the point of view of denture stability, and it is very difficult to satisfy both requirements in the case of a patient who has poor upper and lower alveolar ridges. We investigated the effect of artificial posterior teeth form and occlusal scheme on the distribution of pressure on supporting structures under complete dentures during mastication with upper and lower edentulous simulators. In this report, a guideline for the selection of occlusal scheme for complete dentures, based on our previous investigations, is described. The occlusal scheme remarkably affected the distribution of pressure under simulated complete dentures, as shown by comparing the distribution of pressure using two different occlusal schemes:fully balanced occlusion and lingualized occlusion. However other factors such as posterior teeth form and position affect the distribution of pressure as well, and are related to each other. Therefore, not only occlusal scheme but also posterior artificial teeth form has to be considered, and the form of posterior teeth should be carefully and comprehensively decided when making complete dentures.

  4. Influence of balanced occlusion in complete dentures on the decrease in reduction of an edentulous ridge

    Directory of Open Access Journals (Sweden)

    Poštić Srđan D.

    2012-01-01

    Full Text Available Background/Aim. Balanced occlusal arrangement of artificial teeth and balanced occlusion is a specific type of occlusion that preserves the stability of complete dentures. Balanced occlusion comprises realization of tooth contacts at the working side as well as at the balancing side, at the same time. The aim of this study was to assess the influence of balanced occlusal arrangement of artificial teeth on the decrease in reduction of edentulous alveolar ridge. Methods. A longitudinal study on 91 fully edentulous patients was conducted using their panoramic radiographs and parameters of vertical dimension of edentulous ridges. All the patients were clinically examined by the same and a qualified dental practitioner. Numerical values of parameters of vertical dimensions of edentulous ridges and lines were statistically processed and compared using the Student’s t-test. Results. Vertical dimensions and heights of edentulous ridges were different after comparison of parameters in complete denture wearers with balanced occlusion and complete denture wearers without bilaterally balanced occlusion, as well as between male and female edentulous patients. Statistically significant differences of heights were established in complete denture wearers’ with a set of artificial teeth without balanced occlusion, at the baseline and 12 months after wearing of complete dentures. Conclusion. Balanced occlusion is a favored occlusal design in setting of artificial teeth in conventional complete dentures, which preserves edentulous ridge and influence the stability of dentures.

  5. A randomised controlled trial of complete denture impression materials.

    Science.gov (United States)

    Hyde, T P; Craddock, H L; Gray, J C; Pavitt, S H; Hulme, C; Godfrey, M; Fernandez, C; Navarro-Coy, N; Dillon, S; Wright, J; Brown, S; Dukanovic, G; Brunton, P A

    2014-08-01

    There is continuing demand for non-implant prosthodontic treatment and yet there is a paucity of high quality Randomised Controlled Trial (RCT) evidence for best practice. The aim of this research was to provide evidence for best practice in prosthodontic impressions by comparing two impression materials in a double-blind, randomised, crossover, controlled, clinical trial. Eighty-five patients were recruited, using published eligibility criteria, to the trial at Leeds Dental Institute, UK. Each patient received two sets of dentures; made using either alginate or silicone impressions. Randomisations determined the order of assessment and order of impressions. The primary outcome was patient blinded preference for unadjusted dentures. Secondary outcomes were patient preference for the adjusted dentures, rating of comfort, stability and chewing efficiency, experience of each impression, and an OHIP-EDENT questionnaire. Seventy-eight (91.8%) patients completed the primary assessment. 53(67.9%) patients preferred dentures made from silicone impressions while 14(17.9%) preferred alginate impressions. 4(5.1%) patients found both dentures equally satisfactory and 7 (9.0%) found both equally unsatisfactory. There was a 50% difference in preference rates (in favour of silicone) (95%CI 32.7-67.3%, pUnilever Hatton Award of the International Assocation for Dental Research, Capetown, South Africa, June 2014. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Patient satisfaction with maxillary 3-implant overdentures using different attachment systems opposing mandibular 2-implant overdentures.

    Science.gov (United States)

    Al-Zubeidi, Mohammed I; Alsabeeha, Nabeel H M; Thomson, W Murray; Payne, Alan G T

    2012-05-01

    Patient-based outcomes with maxillary overdentures on a minimum number of implants, opposing mandibular 2-implant overdentures are not evident in the literature. To evaluate patient's satisfaction with maxillary 3-implant overdentures, opposing mandibular 2-implant overdentures, using two different attachment systems over the first 2 years of service. Forty participants wearing mandibular 2-implant overdentures for 3 years were randomly allocated to one of two similar implant system groups to receive maxillary 3-implant overdentures. Twenty participants were allocated to splinted and unsplinted attachment system treatment groups for each system. Patient satisfaction with pre-treatment complete maxillary dentures, with maxillary 3-implant overdentures at baseline and annually for 2 years, was measured using visual analogue scale questionnaires and the oral health impact profiles. Palatal coverage of the maxillary overdentures was reduced at the first annual recall. Data showed significant improvement in pain reduction, comfort, stability, and function variables of the visual analogue scale after treatment. Analysis by prosthodontic design using visual analogue scale showed no significant difference. The total oral health impact profile-14 scores after treatment for all participants, regardless of prosthodontic design, were significantly lower (more satisfied). The overall oral health impact profile-20E score at baseline was significantly higher (more satisfied) compared with pre-treatment conventional maxillary dentures. No significant changes were observed in the first or second years compared with baseline results. Twenty-two participants (84.6%) preferred reduced palatal coverage, regardless of prosthodontic design, after 1 year. Twenty participants (76.9%) still preferred reduced palatal coverage at the end of the second year. The provision of maxillary 3-implant overdentures to oppose mandibular 2-implant overdentures significantly improve levels of patient

  7. Esthetic Rehabilitation with a Cast Partial Denture

    Directory of Open Access Journals (Sweden)

    Suraksha Shrestha

    2017-01-01

    Full Text Available Removable partial denture is a treatment option where fixed prosthesis is not indicated. Due to its esthetic problems in the anterior region various modifications have been designed for its fabrication. This article describes an esthetic alternative using a round rest distal depression clasp for maxillary anterior teeth abutment while restoring the missing teeth with a cast partial denture.

  8. Functional Impressions in Complete Denture and Overdenture Treatment

    OpenAIRE

    Hrvoje Kršek; Nikša Dulčić

    2015-01-01

    Tooth loss can cause loss of occlusal, masticatory, esthetic, physiognomic, phonetic and psychosocial function of patients. The most frequently used treatment method of completely edentulous patients and patients with a small number of remaining teeth are complete dentures or overdentures. One of the most important clinical and laboratory procedures in their fabrication is functional impression taking. The aim of this paper was to present procedures of taking functional impressions in fab...

  9. Enhancing retention of partial dentures using elastomeric retention rings

    Directory of Open Access Journals (Sweden)

    Kakkirala Revathi

    2015-01-01

    Full Text Available This report presents an alternative method for the retention of partial dentures that relies on the engagement of tooth undercuts by a lining material. The lab procedures are also presented. A new maxillary and mandibular acrylic partial dentures were fabricated using elastomeric retention technique for a partially dentate patient. A partially dentate man reported difficulty in retaining his upper removable partial denture (RPD. The maxillary RPD was designed utilizing elastomeric retention technique. During follow-up, it was necessary to replace the retention rings due to wear. The replacement of the retention rings, in this case, was done through a chairside reline technique. Elastomeric retention technique provides exceptionally good retention can be indicated to stabilize, cushion, splint periodontally involved teeth, no enough undercut for clasps, eliminate extractions, single or isolated teeth.

  10. Evaluation of the utility of cephalometric parameters in constructing complete denture. Part I: placement of posterior teeth.

    Science.gov (United States)

    Bassi, F; Deregibus, A; Previgliano, V; Bracco, P; Preti, G

    2001-03-01

    Various types of parameters, including cephalometric ones, have been used in the construction of complete denture. This study aimed to evaluate the utility of cephalometric parameters for this purpose. The position of the posterior teeth in a group of 42 edentulous patients, successfully rehabilitated with complete denture according to clinical parameters, was evaluated by cephalometrics. The following were determined: vertical dimension of occlusion (VDO); orientation of the occlusal plane; and subdivision of the denture space. The cephalometric parameters do not correspond to the clinical positioning of the posterior teeth in successful rehabilitation with complete denture.

  11. Oral manifestations of diabetes mellitus in complete denture wearers.

    Science.gov (United States)

    Cristina de Lima, Danielle; Nakata, Gislaine Cristina; Balducci, Ivan; Almeida, Janete Dias

    2008-01-01

    The oral mucosa has been reported to show a variety of changes in subjects with diabetes mellitus. The purpose of this study was to compare diabetic and nondiabetic subjects wearing complete dentures with regard to salivary flow, salivary buffering capacity, denture retention, and oral mucosal lesions. Sixty subjects, 30 with and 30 without a diagnosis of diabetes, were matched for gender, race, and age. Salivary flow, salivary buffering capacity, glycemia, blood pressure, presence of mucosal lesions, denture retention, use of medications, and behavioral factors (controlled or uncontrolled diet, alcohol consumption, and smoking) reported by the subjects, were evaluated. For the salivary buffering capacity test, 1 mL of saliva was pipetted into a test tube containing 3 mL 0.005 N of hydrochloric acid, and the pH was measured with indicator strips. Group differences were statistically analyzed using the Student t test and the Mann-Whitney test for quantitative variables and the chi-square test for qualitative variables (alpha =.05). Mean (SD) salivary flow was 1.14 (0.87) mL/min in the nondiabetic subjects and 0.95 (0.61) mL/min in the diabetic subjects. Evaluation of self-reported denture retention revealed no significant difference between groups. Denture retention was observed in 66.7% (20/30) of the control group and in 50% (15/30) of the diabetic group. The prevalence of mucosal lesions was 90% (27/30) in the control group and 83.3% (25/30) in the diabetic group. Salivary buffering capacity was 5.80 (0.85) in the control group and 5.26 (0.83) in the diabetic group (P=.017). Within the limitations of this study, no significant differences were observed in salivary flow, denture retention, or oral lesions in diabetic and nondiabetic subjects.

  12. Vinegar as an antimicrobial agent for control of Candida spp. in complete denture wearers

    Directory of Open Access Journals (Sweden)

    Telma Maria Silva Pinto

    2008-12-01

    Full Text Available The use of denture is known to increase the carriage of Candida in healthy patients, and the proliferation of Candida albicans strains can be associated with denture-induced stomatitis. The aim of this study was to evaluate the use of vinegar as an antimicrobial agent for control of Candida spp. in complete upper denture wearers. Fifty-five patients were submitted to a detailed clinical interview and oral clinical examination, and were instructed to keep their dentures immersed in a 10% vinegar solution (pH less than 3 overnight for 45 days. Before and after the experimental period, saliva samples were collected for detection of Candida, counting of cfu/mL and identification of species by phenotypical tests (germ tube formation, chlamidoconidia production, and carbohydrate fermentation and assimilation. The results were analyzed using Spearman's correlation and Student's t-test (p£0.05. Candida yeasts were present in 87.3% of saliva samples before the treatment. A significant reduction was verified in CFU/mL counts of Candida after treatment. A positive correlation between Candida and denture stomatitis was verified, since the decrease of cfu/mL counts was correlated with a reduction in cases of denture stomatitis. Although it was not able to eliminate C. albicans, the immersion of the complete denture in 10% vinegar solution, during the night, reduced the amounts (cfu/mL of Candida spp. in the saliva and the presence of denture stomatitis in the studied patients.

  13. Final-impression techniques and materials for making complete and removable partial dentures.

    Science.gov (United States)

    Jayaraman, Srinivasan; Singh, Balendra P; Ramanathan, Balasubramanian; Pazhaniappan Pillai, Murukan; MacDonald, Laura; Kirubakaran, Richard

    2018-04-04

    Endentulism is relatively common and is often treated with the provision of complete or partial removable dentures. Clinicians make final impressions of complete dentures (CD) and removable partial dentures (RPD) using different techniques and materials. Applying the correct impression technique and material, based on an individual's oral condition, improves the quality of the prosthesis, which may improve quality of life. To assess the effects of different final-impression techniques and materials used to make complete dentures, for retention, stability, comfort, and quality of life in completely edentulous people.To assess the effects of different final-impression techniques and materials used to make removable partial dentures, for stability, comfort, overextension, and quality of life in partially edentulous people. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 22 November 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (Cochrane Register of Studies, to 22 November 2017), MEDLINE Ovid (1946 to 22 November 2017), and Embase Ovid (21 December 2015 to 22 November 2017). The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on language or publication status when searching the electronic databases, however the search of Embase was restricted by date due to the Cochrane Centralised Search Project to identify all clinical trials and add them to CENTRAL. We included randomised controlled trials (RCTs) comparing different final-impression techniques and materials for treating people with complete dentures (CD) and removable partial dentures (RPD). For CD, we included trials that compared different materials or different techniques or both. In RPD for tooth-supported conditions, we included trials comparing the

  14. Comparison of changes in vertical dimension of the upper and lower complete dentures processed using two investing methods

    International Nuclear Information System (INIS)

    Kharat, D.U.; Fakiha, Z.

    1990-01-01

    Standardized compression molding technique was used to process 14 sets of complete dentures. Seven sets of dentures were invested by the conventional method and the other seven were invested by a modified method. In the latter method, the second layer of the investment extended occlusally only up to the maximum convexity on the labial/buccal and lingual surfaces of the teeth. In the beginning, only the upper or the lower denture was processed and changes in the vertical dimension of occlusion were measured. After that, the other denture was also processed and the increase in the vertical dimension of occlusion of the sets of dentures was measured. All measurements were made at the incisal guide pin using a leaf gauge. Statistical analysis using t-test showed no difference in the changes of vertical dimension of the dentures processed by the two different methods of investing. However, both of the methods of investing showed significantly more increase in vertical dimension of the upper complete dentures than that of the lower complete dentures. (author)

  15. Development of chair-side evaluation system of swallowing discomfort of denture wearers

    Science.gov (United States)

    Matsumoto, Keisuke; Ikuta, Ryuhei; Kataoka, Kanako; Ono, Yumie; Tamaki, Katsushi

    2018-02-01

    We investigated the appropriate hemodynamic parameters of functional near-infrared spectroscopy (fNIRS) to best differentiate the discomfort intensity related to swallowing in healthy subjects wearing different types of simulated dentures. Thirty-one subjects performed 4 sessions of water-swallowing task in a sitting position without or with wearing any one of the 3 simulated dentures under continuous fNIRS monitoring of the prefrontal cortex. The simulated dentures were consisted of a flat maxillary palatal bar and bilateral support attachment to the teeth and gum. The palatal bar positions were arranged along with the anterior, middle, or posterior areas of the upper jaw. The cumulative values of oxyhemoglobin and deoxyhemoglobin concentration changes were calculated for periods of 5 - 10 s from completion of swallowing. Subjective rating of swallowing-discomfort was the lowest without wearing denture and increased along with the palatal bar position placed from anterior to posterior. Cumulated deoxyhemoglobin signals calculated for 10 s post-swallowing event in the left frontopolar prefrontal cortex showed the best correlation with the subjective rating of discomfort in swallowing with dentures. These neurological signatures would be beneficial to detect swallowing discomfort in elderly denture wearers who have difficulty in communicating with dentists.

  16. Sectional mandibular complete denture for a total maxillectomy patient with trismus: a clinical report.

    Science.gov (United States)

    Celakil, Tamer; Demir, Azize; Keskin, Haluk

    2017-01-01

    This report presents the case of a 60-year-old male patient with trismus induced by radiotherapy and fabrication of a sectional mandibular complete denture to allow the insertion of the denture into the mouth. A mandibular sectional denture was designed in two pieces with a locking mechanism by using mini anchor and ball abutment housing with cap. Patients who have undergone maxillectomy often have constricted mouth openings, as a result of surgical intervention and radiotherapy, and complain of an inability to insert or remove dentures. A new approach is vital for sectional dentures because existing sectional denture fabrication techniques cannot meet the ongoing needs of trismus patients. The mini anchor system with ball abutment housing has better mechanical retention in acrylic resin and can provide favorable stabilization during masticatory function; thus, additional framework is not required for assisting in stabilization and retention.

  17. The importance of a two-step impression procedure for complete denture fabrication: a systematic review of the literature.

    Science.gov (United States)

    Regis, R R; Alves, C C S; Rocha, S S M; Negreiros, W A; Freitas-Pontes, K M

    2016-10-01

    The literature has questioned the real need for some clinical and laboratory procedures considered essential for achieving better results for complete denture fabrication. The aim of this study was to review the current literature concerning the relevance of a two-step impression procedure to achieve better clinical results in fabricating conventional complete dentures. Through an electronic search strategy of the PubMed/MEDLINE database, randomised controlled clinical trials which compared complete denture fabrication in adults in which one or two steps of impressions occurred were identified. The selections were made by three independent reviewers. Among the 540 titles initially identified, four studies (seven published papers) reporting on 257 patients evaluating aspects such as oral health-related quality of life, patient satisfaction with dentures in use, masticatory performance and chewing ability, denture quality, direct and indirect costs were considered eligible. The quality of included studies was assessed according to the Cochrane guidelines. The clinical studies considered for this review suggest that a two-step impression procedure may not be mandatory for the success of conventional complete denture fabrication regarding a variety of clinical aspects of denture quality and patients' perceptions of the treatment. © 2016 John Wiley & Sons Ltd.

  18. [Occlusal schemes of complete dentures--a review of the literature].

    Science.gov (United States)

    Tarazi, E; Ticotsky-Zadok, N

    2007-01-01

    Occlusal scheme is defined as the form and the arrangement of the occlusal contacts in natural and artificial dentition. The choice of an occlusal scheme will determine the pattern of occlusal contacts between opposing teeth during centric relation and functional movement of the mandible. With dentures, the quantity and the intensity of these contacts determine the amount and the direction of the forces that are transmitted through the bases of the denture to the residual ridges. That is why the occlusal scheme is an important factor in the design of complete dentures. Three occlusal schemes are viewed in this review: bilateral balanced occlusion, monplane occlusion, and linear occlusion scheme. Each scheme represents a different concept of occlusion. Comparisons between these schemes are also reviewed and analyzed. The reasoning underlying the bilateral balanced occlusion scheme is that stability of the dentures is attained when bilateral contacts exist throughout all dynamic and static states of the denture during function. Anatomic teeth are used: the upper anterior teeth are set to satisfy aesthetics, and the posterior teeth are arranged in a compensatory curve and a medial curve. This scheme is adequate for well developed residual ridges, with skeletal class I relation. With highly resorbed residual ridges, the vectors of force that are transmitted through anatomic cusps will dislodge the lower denture and thus impair the comfort and efficiency of mastication experienced by the patient. In order to accommodate to the special needs posed by highly resorbed residual ridges and skeletal relations that are not class I, the monoplane scheme of occlusion was designed. This scheme consists of non anatomic (cuspless) teeth, which are set so that the anterior teeth provide the aesthetics, the premolars and the first molars are used for chewing, and the second molars do not occlude (although sometimes they are specifically used to establish bilateral contacts in lateral

  19. Multicentre prospective evaluation of implant-assisted mandibular bilateral distal extension removable partial dentures: patient satisfaction.

    Science.gov (United States)

    Wismeijer, Daniel; Tawse-Smith, Andrew; Payne, Alan G T

    2013-01-01

    To compare the levels of patient satisfaction with either conventional mandibular bilateral distal extension partial dentures or those assisted by bilateral distal implants. Forty-eight participants who were dissatisfied with their existing conventional mandibular distal extension dentures opposing complete maxillary dentures were selected for a multicentre prospective study in New Zealand, Colombia and the Netherlands. A control group of 12 participants in New Zealand received conventional mandibular partial dentures. Three test groups involving 36 participants in New Zealand (12), Colombia (12) and the Netherlands (12) received bilateral distal implants in the second molar regions. After conventional loading, the test group participants initially had healing caps placed on the distal implants providing support only, followed after approximately 6 months by ball abutments (retentive anchors) for support and retention. Patient outcomes were determined with questionnaires completed at specific stages of the study for up to 3 years. Visual analogue scale, Likert and oral health impact questionnaires before and after treatment indicated improved results. There were significantly improved parameters of overall satisfaction, stability, chewing and appearance after 3 years (P removable partial dentures are a preferable treatment option for patients with complaints about their conventional distal extension partial dentures. © 2011 John Wiley & Sons A/S.

  20. SECTIONAL MANDIBULAR COMPLETE DENTURE FOR A TOTAL MAXILLECTOMY PATIENT WITH TRISMUS: A CLINICAL REPORT

    Directory of Open Access Journals (Sweden)

    Tamer ÇELAKIL

    2017-10-01

    Full Text Available This report presents the case of a 60-year-old male patient with trismus induced by radiotherapy and fabrication of a sectional mandibular complete denture to allow the insertion of the denture into the mouth. A mandibular sectional denture was designed in two pieces with a locking mechanism by using mini anchor and ball abutment housing with cap. Patients who have undergone maxillectomy often have constricted mouth openings, as a result of surgical intervention and radiotherapy, and complain of an inability to insert or remove dentures. A new approach is vital for sectional dentures because existing sectional denture fabrication techniques cannot meet the ongoing needs of trismus patients. The mini anchor system with ball abutment housing has better mechanical retention in acrylic resin and can provide favorable stabilization during masticatory function; thus, additional framework is not required for assisting in stabilization and retention.

  1. Influence of the fast-processing technique on the number of the occlusal contacts and occlusal vertical dimension of complete dentures.

    Science.gov (United States)

    Atashrazm, Parsa; Alavijeh, Leila Zamani; Afshar, Maryam Sadat Sadrzadeh

    2011-03-01

    Occlusal errors during acryl processing affect the retention and stability of complete dentures. The aim of the present study was to assess the influence of a short curing technique on the number of occlusal contacts and the occlusal vertical dimension (OVD) of complete dentures. Complete dentures were prepared. The number of occlusal contacts was recorded in centric relation (CR) using 60 µ articulation paper. The OVD was recorded with the waxed trial denture in place. Dentures were then invested and processed with compression molding and short cure water bath technique. The number of occlusal contacts was recorded again. The amount of pin opening was measured for all of the complete dentures on the articulator. Data were analyzed with paired t-test to determine the alterations. The mean number of occlusal contacts before and after processing was 10.9 ± 2.4 and 6.3 ± 3.1 respectively (4.7 ± 1.9 decrease; p negative effect on the morphologic pattern of artificial teeth of complete dentures and thus should be used carefully.

  2. Trends in complete denture impressions in pakistan

    International Nuclear Information System (INIS)

    Vohra, F.; Rashid, H.; Hanif, A.

    2015-01-01

    Multiple materials and techniques have been reported for complete denture impressions in literature. The aim of the study was to assess the trends in complete denture impression materials and techniques among general dental practitioners (GDP) and specialists (SP) in Pakistan. Methods: In this cross-sectional study, self-designed-structured questionnaires were distributed among 500 dentists in Pakistan. The three-part questionnaire enquired about the demographic features, preferred impression materials, impression techniques and related procedures commonly used in their clinical practice. A comparison between the responses of SP and GDP was also drawn. Frequency distribution and Chi-square test were performed to compare the responses. Results: A total of 294 questionnaires were completed at a response rate of 58.8%. 75% of GDP used alginate for primary impressions and 66% of SP preferred impression compound for the same. A majority of both SP and GDP favoured the used of custom trays (SP 81%, GDP 85%) and selective pressure technique (SP 84%, GDP 53%) for final impression. However, 85% of GDP used zinc-oxide eugenol and 62% of SP favoured elastomeric materials for the same. Most of the SP and GDP used chemical cured resin custom trays (SP 54%, GDP 75%), however, 86% of SP used spaced trays and almost 60% of GDP preferred close-fitting trays. Conclusions: The practice of GDP and SP with regards to CD impression materials and techniques differed significantly. Continued education and training for GDP and SP with respect to procedures and techniques related to CD is recommended. (author)

  3. Evaluation of palatal plate thickness of maxillary prosthesis on phonation- a comparative clinical study.

    Science.gov (United States)

    Zakkula, Srujana; B, Sreedevi; Anne, Gopinadh; Manne, Prakash; Bindu O, Swetha Hima; Atla, Jyothi; Deepthi, Sneha; Chaitanya A, Krishna

    2014-04-01

    Prosthodontic treatment involves clinical procedures which influence speech performance directly or indirectly. Prosthetic rehabilitation of missing teeth with partial or complete maxillary removable dentures influences the individual voice characteristics like Phonation, resonance etc. To evaluate the effect of Acrylic palatal plate thickness (1mm-3mm) of maxillary prosthesis on phonation. Twelve subjects were selected randomly between the age group of 20-25 years who have full complement of teeth and have no speech problems. Speech evaluation was done under four experimental conditions i.e. Without any experimental acrylic palatal plate (control), with experimental acrylic palatal plates of thickness 1 mm, 2 mm and 3 mm respectively. The speech material for phonation test consisted of Vowels sounds /a/, /i/, and /o/. Speech analysis to assess phonation was done using digital acoustic analysis (PRAAT software). The obtained results were statistically analyzed by One-way ANOVA and Tukey's multiple post-hoc for comparison of four experimental conditions with respect to different vowel sounds. Mean harmonics to noise ratio (HNR) values obtained for all the Experimental conditions did not show significant difference (p>0.05). In conclusion, an increase in the thickness of the acrylic palatal plate of maxillary prosthesis for about 1 mm - 3mm in complete or partial maxillary removable dentures resulted in no significant effect on phonation of vowel sounds /a/, /i/ and /o/. Increasing the thickness of the palatal plate from 1 mm to 3 mm has not shown any significant effect on the phonation.

  4. Maxillary overdentures supported by four or six implants in the anterior region: 5-year results from a randomized controlled trial.

    Science.gov (United States)

    Slot, Wim; Raghoebar, Gerry M; Cune, Marco S; Vissink, Arjan; Meijer, Henny J A

    2016-12-01

    To compare a four- and six-implant maxillary overdenture after an observation period of 5 years. Fifty subjects with functional problems concerning their maxillary denture, who had ample bone volume in the anterior region to place four or six implants, were included and randomly assigned to either group. Implant and overdenture survival, clinical performance, marginal bone loss and patient satisfaction were assessed. Forty-six patients completed the 5-year follow-up. One implant failed in the six implants group (99.2% survival) and none in the four implants group (100% survival). No overdentures had to be replaced during the observation period and the number of complications was limited. Clinical function was good, with no difference in clinical parameters between the groups. Mean marginal bone resorption was 0.50 ± 0.37 and 0.52 ± 0.43 mm in the four and six implant group respectively. In patients with functional complaints of their maxillary denture, bar-supported overdentures on four implants in the anterior maxillary region were not inferior to overdentures supported by six implants after 5 years of function. Implant survival and patient satisfaction were high, clinical parameters favourable, bone loss and complications to the denture were minor in both groups (Clinical trial registration number: NTR2969). © 2016 The Authors. Journal of Clinical Periodontology Published by John Wiley & Sons Ltd.

  5. Complications and Clinical Considerations of the Implant-Retained Zirconia Complete-Arch Prosthesis with Various Opposing Dentitions.

    Science.gov (United States)

    Gonzalez, Jorge; Triplett, Robert G

    To evaluate the performance of the implant-retained zirconia complete-arch prosthesis with various opposing dentitions. The 40 patients included in this retrospective case series study were treated with one or two implant-retained zirconia complete-arch prostheses (ZIRCAP) using the Zirkonzahn protocol. Prettau zirconia frames were created with strategic cutbacks in the structure to extend zirconia incisal coverage of the esthetic anterior sextants and complete monolithic zirconia in the molar areas; subsequent layers of porcelain were applied to nonfunctional and esthetic areas. Patients had three possible occlusal scenarios: (1) maxillary ZIRCAP and mandibular ZIRCAP, (2) maxillary ZIRCAP and mandibular natural dentition, and (3) maxillary ZIRCAP and mandibular conventional hybrid prosthesis. Complications were recorded during follow-up appointments 3, 6, and 12 months after definitive prosthesis delivery. The mean treatment observation period was 33 months. Eight prosthetic complications were noted for the 40 implant-retained zirconia complete-arch prostheses (18.18%), including six cases of minor porcelain chipping and two cases of debonding of the metal insert from the zirconia framework. Maxillary ZIRCAP opposing mandibular ZIRCAP and maxillary ZIRCAP opposing mandibular natural dentition occlusal scenarios presented the same complication ratio of 4. No complications were seen in the maxillary ZIRCAP opposing mandibular conventional hybrid prosthesis group, yet 16 complications were found as denture tooth fractures in 12 mandibular conventional hybrid prostheses (ratio of 0.75). The results indicate that the implant-retained zirconia complete-arch prosthesis offers acceptable performance for use as an alternative to the conventional titanium framework acrylic veneer prosthesis for complete edentulism with a lower incidence of prosthetic complications and fewer maintenance appointments. Chipping of veneering porcelain was the most common complication, but a

  6. Influence of reinforcement on strains within maxillary implant overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    2015-01-01

    The purpose of this study was to examine the influence of reinforcement of an embedded cast on the strains within maxillary implant overdentures. A maxillary edentulous model with implants placed bilaterally in the canine positions, dome-shaped copings, and experimental overdentures was fabricated. Rosette-type strain gauges were attached in the canine positions and at three points along the midline of the polished surface of the denture and connected to the sensor interface controlled by a personal computer. Experimental dentures with five different reinforcements were tested: without reinforcement; with a cast cobalt-chrome reinforcement over the residual ridge and the tops of the copings; with the same reinforcement from first molar to first molar, over the residual ridge and the tops of the copings; with the same reinforcement over the residual ridge and the sides of the copings; and with the same reinforcement from first molar to first molar, over the residual ridge and the sides of the copings. A vertical occlusal load of 49 N was applied to the first premolar and then to the first molar, and the strains were measured and compared by analysis of variance. In both loading situations, significantly less strain was recorded in dentures with reinforcement than in those without reinforcement. When the first premolar was loaded on dentures with and without palatal reinforcement at the first premolars, the strains on the denture with reinforcement over the tops of the copings were significantly lower than on the denture with reinforcement over the sides of the copings at the canine position. Cast reinforcement over the residual ridge and the top of copings embedded in an acrylic base reduced the strain from occlusal stress on maxillary implant overdentures.

  7. Patient satisfaction with occlusal scheme of conventional complete dentures: A randomised clinical trial (part I).

    Science.gov (United States)

    Moradpoor, H; Arabzade Hoseini, M; Savabi, O; Shirani, M

    2018-01-01

    Occlusal scheme can affect denture retention, stability, occlusal force distribution, aesthetics, masticatory function, patient comfort and general patient satisfaction with dentures. This study aimed to compare the patient satisfaction with 3 types of complete denture occlusion including fully bilateral balanced occlusion (FBBO), newly presented buccalised occlusion (BO) and lingualised occlusion (LO). In this parallel randomised clinical trial, new conventional complete dentures were fabricated for 86 volunteers. Participants were randomly allocated to 3 groups with 3 different occlusal schemes. All patients were recalled at 1 and 3 months after delivery for data collection. The 19-item version of Oral Health Impact Profile for Edentulous Patients questionnaire was used in this study. The visual analogue scale (VAS) was used for assessment of the prosthodontist's attitude towards denture quality, patient's attitude towards different occlusal schemes and evaluation of patient satisfaction. Data were analysed using the Wilcoxon signed rank test, the Kruskal-Wallis test and the post hoc Dunn test via SPSS version 18.0 (P ≤ .05). Eighty-six patients completed the study, and their data were analysed (mean age ± standard deviation = 57.78 ± 9.98 years). The only significant difference when comparing the 3 groups was physical pain, which was significantly higher in FBBO group. No significant differences were found for the VAS scores of patient and prosthodontist satisfaction or the domain scores among the 3 occlusal schemes either at 1 or at 3 months post-delivery. The VAS score of patient satisfaction and prosthodontist satisfaction increased at third compared to first month after delivery. The results of this randomised clinical trial provided evidence that BO is as effective as LO for the fabrication of complete dentures. © 2017 John Wiley & Sons Ltd.

  8. The Split Denture: Managing Xerostomia in Denture Patients: A Case Report

    OpenAIRE

    Dabas, Nupur; Phukela, Sumit Singh; Yadav, Harish

    2011-01-01

    Wearing complete dentures can be an extremely uncomfortable experience for the people with Xerostomia. Various treatment modalities have been suggested in the literature to overcome the problem of xerostomia in complete denture patients. Incorporating reservoirs containing salivary substitutes, into dentures, is one of these treatment modalities. This paper presents case report of a patient suffering from xerostomia who was successfully treated with a new form of reservoir dentures. This new ...

  9. The patient general satisfaction of mandibular single-implant overdentures and conventional complete dentures: Study protocol for a randomized crossover trial.

    Science.gov (United States)

    Kanazawa, Manabu; Tanoue, Mariko; Miyayasu, Anna; Takeshita, Shin; Sato, Daisuke; Asami, Mari; Lam, Thuy Vo; Thu, Khaing Myat; Oda, Ken; Komagamine, Yuriko; Minakuchi, Shunsuke; Feine, Jocelyne

    2018-05-01

    Mandibular overdentures retained by a single implant placed in the midline of edentulous mandible have been reported to be more comfortable and function better than complete dentures. Although single-implant overdentures are still more costly than conventional complete dentures, there are a few studies which investigated whether mandibular single-implant overdentures are superior to complete dentures when patient general satisfaction is compared. The aim of this study is to assess patient general satisfaction with mandibular single-implant overdentures and complete dentures. This study is a randomized crossover trial to compare mandibular single-implant overdentures and complete dentures in edentulous individuals. Participant recruitment is ongoing at the time of this submission. Twenty-two participants will be recruited. New mandibular complete dentures will be fabricated. A single implant will be placed in the midline of the edentulous mandible. The mucosal surface of the complete denture around the implant will be relieved for 3 months. The participants will then be randomly allocated into 2 groups according to the order of the interventions; group 1 will receive single-implant overdentures first and will wear them for 2 months, followed by complete dentures for 2 months. Group 2 will receive the same treatments in a reverse order. After experiencing the 2 interventions, the participants will choose one of the mandibular prostheses, and yearly follow-up visits are planned for 5 years. The primary outcome of this trial is patient ratings of general satisfaction on 100 mm visual analog scales. Assessments of the prostheses and oral health-related quality of life will also be recorded as patient-reported outcomes. The secondary outcomes are cost and time for treatment. Masticatory efficiency and cognitive capacity will also be recorded. Furthermore, qualitative research will be performed to investigate the factors associated with success of these mandibular

  10. Maxillary Tuberosity Reconstruction with Transport Distraction Osteogenesis

    Directory of Open Access Journals (Sweden)

    F. Ugurlu

    2012-01-01

    Full Text Available Severe bone loss due to pathology in the maxillary tuberosity region is a challenging problem both surgically and prosthetically. Large bone grafts have a poor survival rate due to the delicate bony architecture in this area and presence of the maxillary sinus. Our case presentation describes a new technique for reconstructing severe bony defect in the maxillary tuberosity with horizontal distraction osteogenesis in a 45-year-old man. A 4×6×3cm cyst was discovered in the left maxillary molar region and enucleated. Three months postoperatively, the area had a severe bone defect extending to the zygomatic buttress superiorly and hamular notch posteriorly. Three months later, a bone segment including the right upper second premolar was osteotomised and distracted horizontally. The bone segment was distracted 15 mm distally. After consolidation, implants were placed when the distractor was removed. A fixed denture was loaded over the implants after 3 months. Complete alveolar bone loss extending to the cranial base can be reconstructed with transport distraction osteogenesis. Distalisation of the alveolar bone segment adjacent to the bony defect is an easy method for reconstructing such severe defects.

  11. [Application of individual light-curing resin tray as edge plastic material in complete denture modulo].

    Science.gov (United States)

    Chai, Mei; Tang, Xuyan; Liang, Guangku

    2015-12-01

    To investigate clinical effect of individual light-curing resin tray as edge plastic material in complete denture modulo.
 A total of 30 patients with poor condition for alveolar ridge of mandible were chosen individual tray with individual light-curing resin tray for material edge shaping or traditional individual impression tray for edge shaping cream to produce complete denture. The operability, questionnaire about denture retention, comfort, mucosal cases and chewing function in the process of shaping the edge were investigated three months later after wearing dentures.
 There was no significant difference in retention, comfort, mucosa and the chewing function between the two mandibular denture impression methods. However, the patients with individual light-curing resin tray as edge shaping material felt better in the process than that in the patients with die-cream as the edge shaping material (P<0.05). Furthermore, the manipulation with individual light-curing resin tray as edge shaping material is easy for doctor.
 Although the clinical effect of Individual light-curing resin tray material as the edge shaping material is equal to that of impression cream, it saves time and human resource. Moreover, it is more acceptable for the patients and thus it can be spread in clinics.

  12. Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.

    Science.gov (United States)

    Janeva, Nadica; Kovacevska, Gordana; Janev, Edvard

    2017-10-15

    The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture (CD) fabrication ushered in a new era in removable prosthodontics. Commercially available CAD/CAM denture systems are expected to improve upon the disadvantages associated with conventional fabrication. The purpose of this report is to present the workflow involved in fabricating a CD with a traditional clinical recording method and CAD/CAM technology and to summarize the advantages to the dental practitioner and the patient.

  13. Oral mucosal lesions in denture wearers.

    Science.gov (United States)

    Jainkittivong, Aree; Aneksuk, Vilaiwan; Langlais, Robert P

    2010-03-01

    To determine the prevalence of oral mucosal lesions (OMLs) and denture-related mucosal lesions (DMLs) in denture wearers and to co-relate the prevalence with age, gender, type of denture and any systemic conditions. Dental records of 380 denture wearers were retrospectively reviewed for OMLs and DMLs. We found 45% of the denture wearers had DMLs and 60.8% had OMLs not related to denture wearing. Although the prevalence of DMLs was higher in complete denture wearers than in partial denture wearers (49% vs. 42.2%), this difference was not significant. The most common DMLs were traumatic ulcer (19.5%) and denture-induced stomatitis (18.1%). When analysed by type, traumatic ulcer, denture hyperplasia, frictional keratosis and candidiasis were more common in complete denture wearers, whereas denture-induced stomatitis was more common in partial denture wearers. Frictional keratosis was more common in men than in women. The prevalence of OMLs not related to denture wearing was higher in complete denture wearers than in partial denture wearers, and the most common OML was fissured tongue (27.6%). No association between DMLs and systemic conditions or xerostomic drugs was noted. No differences in the prevalence of DMLs in association with denture type were found. The prevalence of OMLs not related to denture wearing was higher in complete denture wearers than in partial denture wearers. This difference was affected by age, and the data were similar to the findings observed in the elderly.

  14. [Quantitative evaluation of printing accuracy and tissue surface adaptation of mandibular complete denture polylactic acid pattern fabricated by fused deposition modeling technology].

    Science.gov (United States)

    Deng, K H; Wang, Y; Chen, H; Zhao, Y J; Zhou, Y S; Sun, Y C

    2017-06-09

    Objective: To quantitatively evaluate the adaptation of polylactic acid (PLA) pattern of mandibular complete denture fabricated by fused deposition modeling (FDM) technology. Methods: A mandibular complete denture digital model was designed through a complete denture design software based on a pair of standard maxillomandibular edentulous plaster model and their occlusion bases. Ten PLA mandibular complete dentures were printed with a FDM machine. The dentures were scanned with and without the plaster model using a three-dimensional (3D) scanner. In Geomagic software, the scanning data of printed dentures were registered to its computer aided design (CAD) data, and the printing error was analyzed using the multipoint registration command. For quantitatively evaluating the adaptation of the denture, the data of plaster model and PLA denture were registered to the whole data of denture located in the plaster model using the best-fit alignment command, the 3D deviation of the plaster model and tissue surface of the denture represent the space between them. The overall area was separated into three parts: primary stress-bearing area, secondary stress-bearing area and border seal area, and the average deviations of these three parts were measured. The values were analyzed using analysis of variance. Results: Compared with the CAD data, the printing error was (0.013±0.004) mm. The overall 3D deviation between PLA denture and plaster model was (0.164±0.033) mm, in which the primary stress-bearing area was (0.165± 0.045) mm, the secondary stress-bearing area was (0.153 ± 0.027) mm, the border seal area was (0.186 ± 0.043) mm. These showed a good fit in the majority parts of the FDM denture to the plaster model. No statistically significant difference was observed between the three areas ( F =1.857, P =0.175>0.05). Conclusions: Combined with the 3D scanning, CAD and FDM technology, a FDM 3D printing process of complete denture for injection moulding can be established

  15. Effect of Reinforcement Using Stainless Steel Mesh, Glass Fibers, and Polyethylene on the Impact Strength of Heat Cure Denture Base Resin - An In Vitro Study.

    Science.gov (United States)

    Murthy, H B Mallikarjuna; Shaik, Sharaz; Sachdeva, Harleen; Khare, Sumit; Haralur, Satheesh B; Roopa, K T

    2015-06-01

    The impact strength of denture base resin is of great concern and many approaches have been made to strengthen acrylic resin dentures. The objective of this study was to compare the impact strength of the denture base resin with and without reinforcement and to evaluate the impact strength of denture base resin when reinforced with stainless steel mesh, glass fiber, and polyethylene fibers in the woven form. The specimens (maxillary denture bases) were fabricated using a standard polyvinylsiloxane mold with conventional heat cured polymethyl methacrylate resin. The specimens were divided into four groups (n = 10). Group I specimens or control group were not reinforced. Group II specimens were reinforced with stainless steel mesh and Group III and Group IV specimens were reinforced with three percent by weight of glass fibers and polyethylene fibers in weave form respectively. All the specimens were immersed in water for 1-week before testing. The impact strength was measured with falling weight impact testing machine. One-way analysis of variance and Tukey's post-hoc test were used for statistical analysis. Highest impact strength values were exhibited by the specimens reinforced with polyethylene fibers followed by glass fibers, stainless steel mesh, and control group. Reinforcement of maxillary complete dentures showed a significant increase in impact strength when compared to unreinforced dentures. Polyethylene fibers exhibit better impact strength followed by glass fibers and stainless steel mesh. By using pre-impregnated glass and polyethylene fibers in woven form (prepregs) the impact strength of the denture bases can be increased effectively.

  16. Stereotactic radiosurgery with an upper partial denture

    International Nuclear Information System (INIS)

    Tayama, Shusaku; Kunieda, Etsuo; Takeda, Atsushi; Takeda, Toshiaki; Oku, Yohei

    2009-01-01

    A 54-year-old male with partial denture underwent stereotactic radiosurgery with an infrared camera-guided system for a metastatic brain tumor arising from lung cancer. Although this method utilizes a biteplate mounted on the upper jaw to detect head movement, the patient only had four teeth in his upper jaw. In order to stabilize the biteplate, the maxillary denture was fixed to the biteplate with an autopolymerizing resin. In addition, the rest-occlusal position of the lower jaw was impressed on the inferior surface of the biteplate with an autopolymerizing resin. To assess reproducibility and stability, the distance between the left and right incus and left and right markers was measured during pre-planning, as well as before and after stereotactic irradiation. Wearing the biteplate ensures the accuracy of radiotherapy planning for the implementation of radiosurgery in patients who have many maxillary teeth missing. However, a large degree of error was observed when the biteplate was removed. (author)

  17. Orthodontic treatment of a complete transposed impacted maxillary canine

    Directory of Open Access Journals (Sweden)

    Pi-Huei Liu

    2015-03-01

    Full Text Available Tooth transposition is a positional interchange of two adjacent teeth. Transposition most often occurs at maxillary canine. Moving transposed teeth to their normal positions is challenging because this requires bodily movement and translation of one tooth to pass another. This procedure may cause damage to the teeth or supporting structures. We report a case of complete transposition of maxillary canine and lateral incisor. Transposed teeth were successfully moved orthodontically to their normal positions. Multiple mechanics were meticulously applied to achieve complete correction of the tooth positions and to minimize root resorption and/or periodontal defects of canine and lateral incisors. Factors concerning treatment planning for transposed teeth are discussed.

  18. Should edentulous patients be constrained to removable complete dentures? The use of dental implants to improve the quality of life for edentulous patients.

    Science.gov (United States)

    Turkyilmaz, Ilser; Company, Andrea M; McGlumphy, Edwin A

    2010-03-01

    Nowadays, there is some speculation among dental educators that the need for complete dentures will significantly decrease in the future and that training in their provision should be removed from the dental curriculum. To sensitise the reader to the functional shortcomings of complete denture therapy in the edentulous patient and present restorative options including implants to improve edentulous quality of life in these patients. Information retrieval followed a systematic approach using PubMed. English articles published from 1964 to 2008, in which the masticatory performance of patients with implant-supported dentures was assessed by objective methods and compared with performance with conventional dentures, were included. National epidemiological survey data suggested that the adult population in need of one or two complete dentures will increase from 35.4 million adults in 2000 to 37.9 million adults in 2020. Clinical studies have showed that the ratings of general satisfaction were significantly better in the patients treated with implant overdentures post-delivery compared with the complete denture users. In addition, the implant group gave significantly higher ratings on comfort, stability and ability to chew. Furthermore, patients who received mandibular implant overdentures had significantly fewer oral health-related quality of life problems than did the conventional group. Implant-supported dentures including either complete overdentures or a hybrid prosthesis significantly improve the quality of life for edentulous patients compared with conventional removable complete dentures. Therefore, the contemporary dental practitioner should consider other options as well as conventional removable complete dentures to restore edentulous patients.

  19. Implant overdentures: dental students' performance in fabrication, denture quality, and patient satisfaction.

    Science.gov (United States)

    Aragon, Cecilia E; Cornacchio, Angelica Lee Petrina; Ibarra, Lilia Marcela; Saad, Muhammed N; Zibrowski, Elaine

    2010-09-01

    The purpose of this study was to evaluate dental students' performance when fabricating a mandibular two-implant overdenture (OD) as compared to conventional dentures (CD) and to determine if these prostheses were successful. Twenty students and twenty patients were divided into two groups: complete denture group (CDG) and maxillary denture and two-implant OD group (ODG). Students' progress was evaluated at each appointment as they were given a clinical assessment score (CAS), which varied from 1 (unacceptable, needs to repeat procedure) to 4 (acceptable, no errors). The success of the prosthesis was evaluated by the patients using a visual analog scale (VAS) and an expert (a prosthodontist) using a denture quality assessment (DQA) form. Performance for both groups was not statistically different across all eight appointments (CDG 3.16 versus ODG 3.25; p=0.46). Patients with ODs reported greater stability with their dentures (p=0.048) and greater ability to chew than patients with CDs (p=0.03). There were no differences between the groups in terms of expert appraisal (ODG 71.1 versus CDG 67.5; p=0.59). The performance of dental students when fabricating a two-implant OD is thus not different from that of a CD. Students can successfully fabricate a two-implant OD as perceived by both patients and prosthodontists.

  20. [Study of the appearance difference of lower complete denture between functional and anatomic impression techniques].

    Science.gov (United States)

    Zhong, Qun; Wu, Xue-yin; Shen, Qing-yi; Shen, Qing-ping

    2012-04-01

    To compare the difference in oblique external ridge, oblique internal ridge and alveolar process crest of lower complete denture base made through functional impression and anatomic impression techniques. Fifteen patients were chosen to treat with two kinds of complete dentures through functional impression and anatomic impression technique respectively. 3D laser scanner was used to scan the three-dimensional model of the denture base and the differences of the surface structural between two techniques in alveolar process crest, external and internal oblique ridges were analyzed, using paired t test with SPSS 12.0 software package. Between the two techniques, there were significant differences in the areas of internal and external oblique ridge(P0.05). The results explain why there is less tenderness when functional impression technique is applied. The differences measured also indicate that sufficient buffering should be made in external and internal oblique ridge areas in clinic.

  1. Use of a complete denture as a radiation carrier

    International Nuclear Information System (INIS)

    Herring, H.W. Jr.; Greene, P.E.

    1983-01-01

    When surgical resection of intraoral neoplasms is contraindicated, treatment by surface mold irradiation may be used. Success or failure of this mode of treatment may depend on the fabrication of a surface mold that can deliver the prescribed amount of therapeutic radiation in the desired amount of time. A technique for modification of an existing complete denture prosthesis for use as a surface mold has been described. Patient cooperation is essential for successful use of this modified prosthesis

  2. Influence of one- or two-stage methods for polymerizing complete dentures on adaptation and teeth movements

    Directory of Open Access Journals (Sweden)

    Moises NOGUEIRA

    Full Text Available Abstract Introduction The quality of complete dentures might be influenced by the method of confection. Objective To evaluate the influence of two different methods of processing muco-supported complete dentures on their adaptation and teeth movements. Material and method Denture confection was assigned in two groups (n=10 for upper and lower arches according to polymerization method: 1 conventional one-stage - a wax trial base was made, teeth were arranged and polymerized; 2 two-stage method - the base was waxed and first polymerized. With the denture base polymerized, the teeth were arranged and then, performed the final polymerization. Teeth movements were evaluated in the distances between incisive (I-I, pre-molars (P-P, molars (M-M, left incisor to left molar (LI-LM and right incisor to right molar (RI-RM. For the adaptation analysis, dentures were cut in three different positions: (A distal face of canines, (B mesial face of the first molars, and (C distal face of second molars. Result Denture bases have shown a significant better adaptation when polymerized in the one-stage procedure for both the upper (p=0.000 and the lower (p=0.000 arches, with region A presenting significant better adaptation than region C. In the upper arch, significant reduction in the distance between I-I was observed in the one-stage technique, while the two-stage technique promoted significant reduction in the RI-RM distance. In the lower arch, one-stage technique promoted significant reduction in the distance for RI-RM and two-stage promoted significant reduction in the LI-LM distance. Conclusion Conventional one-stage method presented the better results for denture adaptation. Both fabrication methods presented some alteration in teeth movements.

  3. Comparison Predominant Oral micro-flora in Subjects with and without Complete Denture Referred to Yazd Dentistry Department

    Directory of Open Access Journals (Sweden)

    Abbas Ali Jafari

    2014-11-01

    Results: The non-aureus staphylococcus and alpha-hemolytic streptococci showed the highest positive culture among the isolated microorganisms in both groups, whereas beta hemolytic streptococci showed the least percent of isolated microorganism in both groups. The higher density of non-aureus Staphylococci, α-hemolitic Streptococci, Gram negative cocobasillus, non-pathogenic Neisseria, Candida and Corynebacterium were recovered from oral samples of denture users in compare with dentate subjects (P= 0.0001. There was also seen a statistical significant correlation between the number of isolated microorganisms and the duration of denture utilization in denture users (P=0.013. Conclusion: Results of the present study showed that complete denture can be act as a predisposal factor in overgrowing of several oral micro-flora particularly Candida, non-aureus Staphylococci, α-hemolytic streptococci, gram negative cocobacillus, non-pathogenic Neisseria, and Corynebacterium, which emphasized the users denture hygine.

  4. Effects of complete denture wearing on the head posture and posterior airway space: A cephalometric study†

    Directory of Open Access Journals (Sweden)

    Hasan Suat Gokce

    2011-03-01

    Conclusion: Airway protection maintenance with extension and flexion of the head is vital because any rehabilitation involves the head and neck region. Correlation coefficients indicated significant changes in dynamic measurements of the natural head position related to complete dentures. Immediate head extension and alterations of posterior airway dimensions were observed following airway obstruction because of the insertion of complete dentures. The significant changes found in the study should help practitioners understand the mechanisms of craniofacial and cranio-vertical features before planning massive rehabilitations that reduce the oral cavity space.

  5. Video-based Learning Versus Traditional Method for Preclinical Course of Complete Denture Fabrication.

    Science.gov (United States)

    Fayaz, Amir; Mazahery, Azita; Hosseinzadeh, Mohammad; Yazdanpanah, Samane

    2015-03-01

    Advances in computer science and technology allow the instructors to use instructional multimedia programs to enhance the process of learning for dental students. The purpose of this study was to determine the effect of a new educational modality by using videotapes on the performance of dental students in preclinical course of complete denture fabrication. This quasi-experimental study was performed on 54 junior dental students in Shahid Beheshti University of Medical Sciences (SBMU). Twenty-five and 29 students were evaluated in two consecutive semesters as controls and cases, respectively for the same course. The two groups were matched in terms of "knowledge about complete denture fabrication" and "basic dental skills" using a written test and a practical exam, respectively. After the intervention, performance and clinical skills of students were assessed in 8 steps. Eventually, a post-test was carried out to find changes in knowledge and skills of students in this regard. In the two groups with the same baseline level of knowledge and skills, independent T-test showed that students in the test group had a significantly superior performance in primary impression taking (p= 0.001) and primary cast fabrication (p= 0.001). In terms of anterior teeth set up, students in the control group had a significantly better performance (p= 0.001). Instructional videotapes can aid in teaching fabrication of complete denture and are as effective as the traditional teaching system.

  6. Influence of high expansion dental stone used as investing medium on the changes in occlusal vertical dimension of complete dentures.

    Science.gov (United States)

    Salloum, Alaa'a M

    2013-10-01

    Despite advances in materials and techniques, complete dentures made of acrylic resin experience an increase in the occlusal vertical dimension (OVD) during processing. Many factors that affect the OVD of complete dentures are known. However, no study has examined the effect of using high-expansion dental stone (type V) as an investing material on the OVD. This study investigated the effects of using a high-expansion dental stone as an investing material on changes in the OVD of complete dentures. Twenty sets of simulated upper and lower dentures were processed by the compression molding technique. Specimens were equally divided into 2 groups. In the dental stone type III (DST III) group, the lower, middle, and upper parts of a flask were filled with DST III. In the dental stone type V (DST V) group, the procedure was the same as in the DST III group, except that the middle layer was made of high-expansion DST V. Changes in the OVD were measured before and after denture processing. Collected data were analyzed with t-test statistics. Differences were considered statistically significant at the 95% confidence level. Both groups showed a small increase in the OVD as a result of processing, but the OVD increase was significantly less in the DST V group compared to the DST III group. High-expansion DST V can be recommended as an investing material to reduce the increase in the OVD that may occur while processing complete dentures.

  7. Prosthodontic Rehabilitation of Hereditary Ectodermal Dysplasia in an 11-Year-Old Patient with Flexible Denture: A Case Report

    Directory of Open Access Journals (Sweden)

    Neha Jain

    2012-01-01

    Full Text Available Hereditary ectodermal dysplasia is a rare group of inherited disorders characterized by aplasia or dysplasia of two or more tissues of ectodermal origin such as hair, nails, teeth, and skin. The dental characteristics of this syndrome include anodontia or hypodontia of the primary and/or permanent teeth, hypoplastic conical teeth, and underdevelopment of the alveolar ridges. The options for a definitive treatment plan include fixed, removable or implant-supported prostheses, singly or in combination. This clinical report describes the prosthetic rehabilitation of an 11-year-old boy with hereditary ectodermal dysplasia. Maxillary flexible removable partial denture and mandibular conventional complete denture were fabricated to establish an acceptable masticatory function, speech, and esthetics for the patient.

  8. Evaluation of the efficiency of denture cleaners for removing denture adhesives.

    Science.gov (United States)

    Harada-Hada, Kae; Hong, Guang; Abekura, Hitoshi; Murata, Hiroshi

    2016-12-01

    We developed a new scoring index for assessing the removability of denture adhesives and evaluated the removal efficiency of denture cleaners. Although our understanding of the importance of denture care is increasing, little is known about the effectiveness and efficiency of denture cleaners on denture adhesives. Therefore, guidelines for proper cleaning are necessary. We used five denture cleaner solutions on two cream adhesives, one powder adhesive and one cushion adhesive. After immersion in the denture cleaners for a designated time, we evaluated the area of the sample plate still covered by denture adhesive. Cream adhesives were removed more completely after immersion in majority of the denture cleaners than in water. Powder adhesive was removed more quickly than cream adhesives. Cushion adhesive was not removed by immersion in either the denture cleaners or water control. Some denture cleaners could liquefy cream adhesives more than water, but these differences were not observed in case of powder and cushion adhesives. © 2015 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  9. Effect of telescopic distal extension removable partial dentures on oral health related quality of life and maximum bite force: A preliminary cross over study.

    Science.gov (United States)

    Elsyad, Moustafa Abdou; Mostafa, Aisha Zakaria

    2018-01-01

    This cross over study aimed to evaluate the effect of telescopic distal extension removable partial dentures on oral health related quality of life and maximum bite force MATERIALS AND METHODS: Twenty patients with complete maxillary edentulism and partially edentulous mandibles with anterior teeth only remaining were selected for this cross over study. All patients received complete maxillary dentures and mandibular partial removable dental prosthesis (PRDP, control). After 3 months of adaptation, PRDP was replaced with conventional telescopic partial dentures (TPD) or telescopic partial dentures with cantilevered extensions (TCPD) in a quasi-random method. Oral health related quality of life (OHRQoL) was measured using OHIP-14 questionnaire and Maximum bite force (MBF) was measured using a bite force transducer. Measurements were performed 3 months after using each of the following prostheses; PRDP, TPD, and TCPD. TCPD showed the OHIP-14 lowest scores (i.e., the highest patient satisfaction with their OHRQoL), followed by TPD, and PRDP showed the highest OHIP-14 scores (i.e., the lowest patient satisfaction with OHRQoL). TCPD showed the highest MBF (70.7 ± 3.71), followed by TPD (57.4 ± 3.43) and the lowest MBF (40.2 ± 2.20) was noted with PRDP. WITHIN The Limitations of This Study, Mandibular Telescopic Distal Extension Removable Partial Dentures with Cantilevered Extensions Were Associated with Improved Oral Health Related Quality of Life and Maximum Bite Force Compared to Telescopic or Conventional PRDP. Telescopic distal extension removable prostheses is an esthetic restoration in partially edentulous patients with free end saddle. This article describes the addition of cantilevered extensions of this prosthesis. The results showed that telescopic distal extension removable prostheses with cantilevered extensions were associated with improved oral health related quality of life and maximum bite force compared to telescopic or conventional RPDs

  10. A Randomized Controlled Trial of Mastication with Complete Dentures Made by a Conventional or an Abbreviated Technique.

    Science.gov (United States)

    Mengatto, Cristiane Machado; Gameiro, Gustavo Hauber; Brondani, Mario; Owen, C Peter; MacEntee, Michael I

    The aim of this randomized clinical trial was to test the hypothesis that there are no statistically significant differences after 3 and 6 months in masticatory performance or chewing ability of people with new complete dentures made by an abbreviated or a conventional technique. The trial included 20 edentulous participants at a dental school in Brazil assigned randomly to receive dentures made by either a conventional technique involving six clinical sessions or by an abbreviated technique involving three clinical sessions. At baseline with old dentures and at 3 and 6 months with new dentures, masticatory performance was measured by counting the number of chewing strokes and the time before participants had an urge to swallow and by calculating the medium particle size of a silicone material after 20 chewing strokes and at the urge to swallow. On each occasion, the participants recorded on visual analog scales their ability to chew five food textures. Statistical significance (P ≤ .05) of changes in masticatory performance and chewing ability during the trial were analyzed with generalized estimating equations. Both techniques improved masticatory performance between baseline and 6 months and the ability to bite and chew all foods apart from hard apples. There were no significant differences in masticatory performance or chewing ability after 6 months between complete dentures made by a conventional or an abbreviated technique.

  11. Duplication of complete dentures using general-purpose handheld optical scanner and 3-dimensional printer: Introduction and clinical considerations.

    Science.gov (United States)

    Kurahashi, Kosuke; Matsuda, Takashi; Goto, Takaharu; Ishida, Yuichi; Ito, Teruaki; Ichikawa, Tetsuo

    2017-01-01

    To introduce a new clinical procedure for fabricating duplicates of complete dentures by bite pressure impression using digital technology, and to discuss its clinical significance. The denture is placed on a rotary table and the 3-dimensional form of the denture is digitized using a general-purpose handheld optical scanner. The duplicate denture is made of polylactic acid by a 3-dimensional printer using the 3-dimensional data. This procedure has the advantages of wasting less material, employing less human power, decreasing treatment time at the chair side, lowering the rates of contamination, and being readily fabricated at the time of the treatment visit. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  12. Antimicrobial activity of denture adhesive associated with Equisetum giganteum- and Punica granatum-enriched fractions against Candida albicans biofilms on acrylic resin surfaces.

    Science.gov (United States)

    Almeida, Nara Ligia Martins; Saldanha, Luiz Leonardo; da Silva, Rafaela Alves; Pinke, Karen Henriette; da Costa, Eliane Ferraz; Porto, Vinicius Carvalho; Dokkedal, Anne Lígia; Lara, Vanessa Soares

    2018-01-01

    Candida biofilms adhere to the internal surface of removable dentures, which is an etiological factor in the pathogenesis of denture stomatitis (DS). Adhesive materials are used at the base of maxillary complete dentures to improve their retention and chewing qualities. This article reports the antimicrobial activity of the enriched fractions of Equisetum giganteum and Punica granatum incorporated into a denture adhesive against C. albicans biofilm. The biofilms were induced on the surface of heat-cured acrylic resin specimens that were previously treated with a mixture of adhesive/herb extracts. The antimicrobial activity was evaluated by CFU counts, XTT reduction, and SEM and CLSM analysis. Both herb extracts amplified the anti-biofilm action of the adhesive on the acrylic resin by up to 12 h. Therefore, when these extracts were combined with COREGA®, they played a collaborative and innovative role in biofilm control and can be considered alternatives for temporary use in the treatment and/or prevention of DS.

  13. Clinical strategies for complete denture rehabilitation in a patient with Parkinson disease and reduced neuromuscular control.

    Science.gov (United States)

    Haralur, Satheesh B

    2015-01-01

    The dentist has a large role in geriatric health care for the ever increasing elder population with associated physical and neurological disorders. The Parkinson disease is progressive neurological disorder with resting tremor, bradykinesia, akinesia, and postural instability. The psychological components of disease include depression, anxiety, and cognitive deficiency. Poor oral hygiene, increased susceptibility for dental caries, and periodontal diseases predispose them to early edentulism. The number of Parkinson affected patients visiting dental clinic seeking complete denture is growing. This case report explains the steps involved in the complete denture rehabilitation of Parkinson patient. The effective prosthesis will help in alleviating functional, aesthetic, and psychological disabilities of the patient.

  14. Clinical Strategies for Complete Denture Rehabilitation in a Patient with Parkinson Disease and Reduced Neuromuscular Control

    Directory of Open Access Journals (Sweden)

    Satheesh B. Haralur

    2015-01-01

    Full Text Available The dentist has a large role in geriatric health care for the ever increasing elder population with associated physical and neurological disorders. The Parkinson disease is progressive neurological disorder with resting tremor, bradykinesia, akinesia, and postural instability. The psychological components of disease include depression, anxiety, and cognitive deficiency. Poor oral hygiene, increased susceptibility for dental caries, and periodontal diseases predispose them to early edentulism. The number of Parkinson affected patients visiting dental clinic seeking complete denture is growing. This case report explains the steps involved in the complete denture rehabilitation of Parkinson patient. The effective prosthesis will help in alleviating functional, aesthetic, and psychological disabilities of the patient.

  15. Denture adhesives improve mastication in denture wearers.

    Science.gov (United States)

    Gonçalves, Thais Marques Simek Vega; Viu, Flavia Carvalho; Gonçalves, Leticia Machado; Garcia, Renata Cunha Matheus Rodrigues

    2014-01-01

    This clinical trial evaluated the influence of denture adhesive (DA) use on masticatory function in denture wearers according to their denture-bearing ridge status. Thirty edentulous subjects, wearing new well-fitting dentures, were classified as having either a normal or resorbed ridge. Mastication was evaluated in patients who completed chewing tests with and without two DA substances (cream or strips), which were randomly assigned. A chewing test with a sieve method analyzed masticatory performance. A kinesiographic device evaluated chewing cycle, and a visual analog scale measured masticatory ability. Data were submitted to Mauchly's sphericity test, and PROC MIXED procedures were conducted on repeated measures. Tukey-Kramer tests performed appropriate statistical comparisons (P ≤ .05). DA use increased masticatory performance and ability in patients with both ridge types (P mastication by shortening the chewing cycle and by enhancing chewing ability and performance.

  16. Comparison of patient's satisfaction with implant-supported mandibular overdentures and complete dentures

    Directory of Open Access Journals (Sweden)

    Yu-Hwa Pan

    2014-06-01

    Full Text Available Background: The purpose of this study was to compare patients' subjective experiences with respect to long-term satisfaction with mandibular implant-retained overdentures versus conventional complete dentures. Methods: Among 85 completely edentulous patients, 60 were treated with four one-stage titanium implants and overdentures retained by a cast bar with extracoronal attachments. These patients constituted the experimental group, and were subsequently evaluated clinically over a period of up to 6 years. The other 25 patients constituted the control group and were treated with conventional complete dentures without implant retained. All the patients (n = 60 in the experimental group responded to questions on their experiences before and after treatment with the implant-retained overdentures. Sixty percent (n = 15 of the 25 patients in the control group responded to the questionnaire. Results: No implants or restorations failed during the observation period. The experimental group, however, showed significant differences with the control group in terms of their responses to the questionnaire. Conclusion: The use of implants to retain and support the overdenture improved comfort and gave the experimental patients greater self-confidence in social interactions, in addition to more effective oral rehabilitation. The results demonstrate that the effects of rehabilitation of the mandibular arch with an implant-retained overdenture are predictable.

  17. A clinical study to compare between resting and stimulated whole salivary flow rate and pH before and after complete denture placement in different age groups.

    Science.gov (United States)

    Muddugangadhar, B C; Sangur, Rajashekar; Rudraprasad, I V; Nandeeshwar, D B; Kumar, B H Dhanya

    2015-01-01

    This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics.

  18. Effect of Gamma Radiation sterilization versus Disinfection on Removable Partial Dentures (Microbiological study)

    International Nuclear Information System (INIS)

    Mohammed, M.A.

    2011-01-01

    The aim of the study was to compare between the effectiveness of disinfection, using commercially available Fittydent super cleansing tablets versus sterilization, using gamma radiation on candidal growth in maxillary removable partial dentures. Methods: Fourteen partially edentulous subjects were selected according to specific criteria and divided equally and randomly into two groups; Group I: disinfection group and Group II: sterilization group. Conventional maxillary removable partial dentures were constructed for all subjects. The swab technique was used to collect the samples one month after denture delivery, immediately after disinfection/sterilization, and then one week, two weeks, three weeks, four weeks, and five weeks after disinfection/sterilization respectively. Bacteriological candidal colony count was performed using a manual contact colony counter. Results: Both methods (disinfection and sterilization) led to a noticeable decrease in the candidal count. However this decrease was highly and markedly evident in Group II as compared to Group I. Infact, no candidal growth was recorded for group II immediately after strerilization and was maintained for two more weeks. Statistical analysis revealed highly significant differences between the two groups. Conclusions: Both methods were effective in decreasing the number of Candida albicans adhering to the denture. However, sterilization using Gamma radiation had a more superior immediate, as well as, long term efficiency as compared to disinfection using Fittydent super cleansing tablets.

  19. Prevalence of signs and symptoms of temporomandibular disorders (TMD) in patients wearing bimaxillary complete dentures, removable partial dentures and in students with natural dentition.

    Science.gov (United States)

    Bordin, Thaisa B; Conci, Ricardo A; Pezzini, Maristela M G; Pezzini, Rolando P; Mendonça, Márcio J

    2013-01-01

    Temporomandibular Disorder (TMD) has attained a prominent role within the context of dental care due to its high prevalence. The aim of this study was to evaluate the prevalence of signs and symptoms of TMD in students at the State University of West of Paraná (UNIOESTE) with natural dentition, and in patients with removable partial dentures and double complete dentures. A total of 210 randomly selected individuals of both genders were evaluated, being divided into three groups: seventy students at the UNIOESTE with natural dentition (Group 1), seventy patients with removable partial dentures (Group 2) and seventy patients with bimaxillary complete dentures (Group 3). The data were collected by a single examiner using the American Academy of Orofacial Pain questionnaire for triage, where a single affirmative response to any of the situations mentioned was enough to carry out clinical evaluation. Kolmogorov Smirnov, Mann Whitney, Chi-Square, ANOVA and Tukey's statistical tests were performed. The most prevalent signs and symptoms of TMD in Group 1 were pain or difficulty in chewing or talking, perception of recent change in bite and deviations during the course of mandibular movements. In Group 2 they were perceptions of recent changes in the bite, deflections in the mandibular movements, presence of joint sounds, pain during excursive movements and muscle tenderness. The most prevalent signs and symptoms in Group 3 were limited to mouth opening and poor stability and retention of at least one of the prostheses. Group 3 also reported having received treatment for headaches or facial pain with a high prevalence. Group 2 had the highest prevalence of signs and symptoms. Prevalence was similar in Groups 1 and 3.

  20. A clinical study to compare between resting and stimulated whole salivary flow rate and pH before and after complete denture placement in different age groups

    Science.gov (United States)

    Muddugangadhar, B. C.; Sangur, Rajashekar; Rudraprasad, I. V.; Nandeeshwar, D. B.; Kumar, B. H. Dhanya

    2015-01-01

    Purpose: This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Materials and Methods: Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Results: Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Conclusion: Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. Clinical Implications: The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics. PMID:26929540

  1. Diagnosis and treatment of orofacial pain in a patient with unserviceable complete dentures: A clinical report.

    Science.gov (United States)

    Selecman, Audrey M; Ahuja, Swati A

    2018-02-08

    An ill-fitting complete denture has the potential to create pain and discomfort as well as conceal or confound the diagnosis of other primary sources of orofacial pain such as trigeminal neuralgia. Guidelines of the American Academy of Orofacial Pain offer an evidence-based approach for the assessment, diagnosis, and management of orofacial pain. A complete and accurate differential diagnosis is paramount to the success of treatment as well as to the circumvention of unnecessary therapy. The purpose of this clinical report was to emphasize an evidence-based approach to the diagnosis and treatment of orofacial pain in a patient with edentulism and a history of prolonged denture wear. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Flipped clinical training: a structured training method for undergraduates in complete denture prosthesis.

    Science.gov (United States)

    K, Anbarasi; K, Kasim Mohamed; Vijayaraghavan, Phagalvarthy; Kandaswamy, Deivanayagam

    2016-12-01

    To design and implement flipped clinical training for undergraduate dental students in removable complete denture treatment and predict its effectiveness by comparing the assessment results of students trained by flipped and traditional methods. Flipped training was designed by shifting the learning from clinics to learning center (phase I) and by preserving the practice in clinics (phase II). In phase I, student-faculty interactive session was arranged to recap prior knowledge. This is followed by a display of audio synchronized video demonstration of the procedure in a repeatable way and subsequent display of possible errors that may occur in treatment with guidelines to overcome such errors. In phase II, live demonstration of the procedure was given. Students were asked to treat three patients under instructor's supervision. The summative assessment was conducted by applying the same checklist criterion and rubric scoring used for the traditional method. Assessment results of three batches of students trained by flipped method (study group) and three traditionally trained previous batches (control group) were taken for comparison by chi-square test. The sum of traditionally trained three batch students who prepared acceptable dentures (score: 2 and 3) and unacceptable dentures (score: 1) was compared with the same of flipped trained three batch students revealed that the number of students who demonstrated competency by preparing acceptable dentures was higher for flipped training (χ 2 =30.996 with p<0.001). The results reveal the supremacy of flipped training in enhancing students competency and hence recommended for training various clinical procedures.

  3. Color stability of different denture teeth materials: an in vitro study.

    Science.gov (United States)

    Mutlu-Sagesen, L; Ergün, G; Ozkan, Y; Bek, B

    2001-09-01

    The aim of this in vitro study was to compare the color stability of commercially available porcelain, reinforced acrylic, and conventional acrylic denture teeth materials used in removable prostheses. Two brands of porcelain (Unilux-Enta Lactona-Holland and Vivoperl-Ivoclar-Liechtenstein), 2 brands of reinforced acrylic (Optodent-Bayer-Germany and Ivolek-Ivoclar-Liechtenstein), and 2 brands of conventional acrylic (Isodent-Güney Diş Deposu-Turkey and Samed-Turkey), were made, for a total of 6 different denture teeth groups. Denture teeth were subjected to 3 staining solutions (filtered coffee, tea, and cola) and distilled water. From each group of denture teeth, 4 sets of maxillary anterior denture teeth were immersed in each of the 4 solutions. The color values of denture teeth were measured colorimetrically with the Gardner XL 20 Tristimulus Colorimeter (Gardner Lab. Inc., Bethesda, Maryland, USA). Color changes were characterized in the CIEL*a*b* color space. Color change values were determined after 1 day, 1 week, 2 weeks, and 4 weeks. The color difference values were calculated and then evaluated by two-way ANOVA statistically. The filtered coffee solution was found to be more chromogenic than the other 2 staining solutions, while porcelain denture teeth materials were more color stable. Assuming the color change of deltaE* < 1.0 as a discernible limit and deltaE* = 3.3 as an acceptable value, the filtered coffee, tea, and cola had slight staining effects on all 6 groups of denture teeth.

  4. The value of the Gothic arch tracing in the positioning of denture teeth.

    Science.gov (United States)

    el-Gheriani, A S; Winstanley, R B

    1988-07-01

    Twenty-five subjects of three nationalities carried out Gothic arch tracings. Measurements between the side arms were compared with the upper intercuspid distances measured in the same subjects. A relationship was found which may be of value in the setting up of anterior maxillary denture teeth.

  5. Finite element analysis to compare complete denture and implant-retained overdentures with different attachment systems.

    Science.gov (United States)

    Barão, Valentim Adelino Ricardo; Assunção, Wirley Gonçalves; Tabata, Lucas Fernando; Delben, Juliana Aparecida; Gomes, Erica Alves; de Sousa, Edson Antonio Capello; Rocha, Eduardo Passos

    2009-07-01

    This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred in supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

  6. Attachment of clips in a bar-retained maxillary implant overdenture : a clinical report

    NARCIS (Netherlands)

    Slot, J.W.A.; Raghoebar, G.M.; Dijk, G. van; Meijer, H.J.A.

    Implant-supported overdentures are a good alternative for patients with conventional dentures that lack retention and stability. The most common prosthetic complications in mandibular and maxillary implant-supported overdentures are fracture and loosening of the attachment system. This clinical

  7. Candida colonization on the denture of diabetic and non-diabetic patients

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Lotfi-Kamran

    2009-01-01

    Full Text Available Background: Oral candidiasis is a common opportunistic infection in diabetic patients. Presence of denture in the oral cavity of diabetic patients can promote Candida colonization and results in the higher incidence of oral and systemic candidiasis. The general purpose of the present study was to evaluate and compare Candida colonization in denture of diabetic patients and non-diabetic control group. Methods: In current case-control study, samples for mycological examinations were collected from the palatal impression surface of maxillary dentures from 92 edentulous patients including 46 dia-betic and 46 non-diabetic denture wearers. All samples were cultured directly on sabouraud agar me-dium and isolated colonies were counted and identified based on specific tests. Data were statistically analyzed using Mann-Whitney and Spearman correlation tests. Results: The higher density of isolated colonies was seen in diabetic group in compare with control group (P = 0.0001. There was a statistically significant correlation between the blood glucose level (P = 0.0001 and the duration of denture usage (P = 0.022 with the colonization of Candida on den-ture of diabetic patients. C. albicans was the most common isolated Candida species in both groups, though diabetic patients with dentures had more non-albicans Candida isolated from their dentures compared to non-diabetic patients. Conclusions: Mycological findings from the present study revealed that diabetes mellitus can in-crease colonization of Candida in denture and mouth. By elimination of local and systemic factors in diabetic patients and improving their oral health care, Candida colonization and the risk of oral and systemic candidiasis will be decreased.

  8. Evaluation of denture hygiene among removable denture wearers referred to clinics of Kerman, Iran

    Directory of Open Access Journals (Sweden)

    Molouk Torabi Parizi

    2013-06-01

    Full Text Available BACKGROUND AND AIM: The number of patients who need prosthetic treatments has increased. Efficient and regular procedures for cleaning removable dentures are important for maintaining good oral health. The aim of this study was to analyze the oral and prostheses care habits of removable denture users, who attended the clinics of Kerman, Iran. METHODS: This cross-sectional study was carried out on 350 patients, who attended the clinics of Kerman and were chosen by the multistage sampling method. Data were obtained from a checklist consisting of demographic characteristics (age, sex, educational level, kind of prosthesis, age of prosthesis, self-report of halitosis, and smoking status, denture hygiene habits, denture-wearing behavior, and cleanliness of denture by examiner. Data was analyzed using chi-squared test (P < 0.05. RESULTS: The mean age of patients was 58.52 ± 10.78 years, 103 (29.4% were male and 247 (70.6% were female. The results showed that 78.6% had complete denture and 12.7% reported halitosis, 55.1% used their denture at night, and 36.4% had poor denture hygiene. Brushing was the most used cleaning method by the patients (36.5%. 60.4% reported never having been instructed by their dentists as to how to clean their dentures. 58.6% had been using the same denture for more than 5 years. There was a significant correlation between the kind of denture, and denture hygiene and education level. CONCLUSION: According to the results of the present study denture hygiene was not favorable. Therefore, dentists should instruct the patients on cleaning their denture in order to prevent denture–induced lesions.

  9. Lost salt technique for severely resorbed alveolar ridges: An innovative approach

    Directory of Open Access Journals (Sweden)

    Himanshi Aggarwal

    2012-01-01

    Full Text Available The success of a complete denture relies on the principles of retention, stability and support. The prosthodontist skill lies in applying these principles efficiently in critical situations. Severely resorbed maxillary edentulous ridges that are narrow and constricted with increased inter ridge space provide decreased support, retention and stability. The consequent weight of the processed denture only compromises them further. This article describes a case report of an edentulous patient with resorbed ridges where a simplified technique of fabricating a hollow maxillary complete denture using lost salt technique was used for preservation of denture bearing areas. The hollowing of the denture reduces the weight of the denture, thereby enhancing stability and retention, reducing the further resorption of the jaws.

  10. A simplified method to reduce prosthetic misfit for a screw-retained, implant-supported complete denture using a luting technique and laser welding.

    Science.gov (United States)

    Longoni, Salvatore; Sartori, Matteo; Davide, Roberto

    2004-06-01

    An important aim of implant-supported prostheses is to achieve a passive fit of the framework with the abutments to limit the amount of stress transfer to the bone-implant interface. An efficient and standardized technique is proposed. A definitive screw-retained, implant-supported complete denture was fabricated for an immediately loaded provisional screw-retained implant-supported complete denture. Precise fit was achieved by the use of industrial titanium components and the passivity, by an intraoral luting sequence and laser welding.

  11. Clinical comparison of masticatory performance and electromyographic activity of patients with complete dentures, overdentures, and natural teeth.

    Science.gov (United States)

    Rissin, L; House, J E; Manly, R S; Kapur, K K

    1978-05-01

    In this study, which is the first of its kind, it has been shown that overdenture patients, when compared to complete denture patients, while chewing a test food for a constant number of strokes, expended an equivalent amount of muscle effort, chewed more slowly and efficiently, and evidenced significantly better masticatory performance by producing an increased volume of fine test food particles. These findings provide a sound justification for the extra effort required to retain some natural teeth to provide overdenture services to patients. The fact that patients can masticate food more efficiently with overdentures than with complete dentures justifies the increased cost and time involved in their construction. The longitudinal effects that overdentures have on the basic physiopathologic processed involved in the progression of ridge resorption and the advantages of maintaining periodontal proprioception also should be studied.

  12. [Treatment of removable partial dentures. 2. Causes and consequences of a reduced occlusal system

    NARCIS (Netherlands)

    Witter, D.J.; Barel, J.C.; Baat, C. de; Keltjens, H.M.A.M.; Creugers, N.H.J.

    2011-01-01

    The occlusal system is part of the orofacial system and consists of the maxillary and mandibular alveolar ridge and teeth which are occluding or not or the removable denture teeth. The most prevalent causes of loss of teeth are insufficient oral self care or inadequate professional oral healthcare

  13. Clinical evaluation of removable partial dentures on the periodontal health of abutment teeth: a retrospective study.

    Science.gov (United States)

    Dula, Linda J; Ahmedi, Enis F; Lila-Krasniqi, Zana D; Shala, Kujtim Sh

    2015-01-01

    The aim of this retrospective study was to evaluate the effect of removable partial dentures in periodontal abutment teeth in relation to the type of denture support and design of RPD in a five-year worn period. Methods : A total of 64 patients with removable partial dentures (RPDs), participated in this study. It were examined ninety-one RPDs. There were seventy-five RPDs with clasp-retained and sixteenth were RPDs with attachments. There were 28 females and 36 males, aged between 40-64 years, 41 maxillary and 50 mandible RPDs. For each subjects the following data were collected: denture design, denture support, and Kennedy classification. Abutment teeth were assessed for plaque index (PI), calculus index (CI), blending on probing (BOP), probing depth (PD), gingival recession (GR), tooth mobility (TM). Level of significance was set at pdenture support of RPD, BOP, PD, PI, GR, CI and TM-index showed no statistically significant difference. Based on the denture design of RPD's, BOP, PD, PI, CI, and TM-index proved no statistically significant difference. Except GR-index according to denture design confirmed statistically significant difference in RPD with clasp pdentures and below the clasp arms in abutment teeth.

  14. Epidemiological Data and Survival Rate of Removable Partial Dentures

    Science.gov (United States)

    Moreno, Amália; Haddad, Marcela Filié; Rocha, Eduardo Passos; Assunção, Wirley Gonçalves; Filho, Humberto Gennari; Santos, Emerson Gomes Dos; Sonego, Mariana Vilela; Santos, Daniela Micheline Dos

    2016-01-01

    Introduction The use of removable partial denture (RPD) is considered as low-cost and common treatment option to rehabilitate edentulous areas. Aim This study aimed to investigate the epidemiological data of patients rehabilitated with removable partial denture (RPD) in order to assess treatment survival rate and failures. Materials and Methods Epidemiological data and medical records of patients treated with RPD between 2007 and 2012 at the RPD discipline of a Brazilian University (Aracatuba Dental School- UNESP) were evaluated as well as dental records of patients who underwent RPD treatments (fabrication or repairs) between 2000 and 2010. Factors such as gender, age, presence of systemic disease, main complaint, edentulous arch, period and cause of denture replacement and the prosthesis characteristics were recorded. The chi-square test was used to assess the differences between the variables and the Kaplan Meyer to assess the survival of the RPDs evaluated. Results A total of 324 maxillary RPD and 432 mandibular RPD were fabricated. Most of the patients were women aging 41 to 60-year-old. The number of mandibular RPD Kennedy class I (26%) was statistically higher for the maxillary arch (p<.05). There was no association between main complaint to gender or the presence of systemic disease. The lingual plate was the most common major connector used in the mandible (32%). The main reason for altering the design of replaced RPDs were changes during treatment plan. Conclusion The number of patients who require RPD is large; most of RPDs are Kennedy Class I. A good treatment plan is very important for achieving a positive treatment outcome, and it is strictly related to the survival rate. PMID:27437367

  15. Effects of glass fiber mesh with different fiber content and structures on the compressive properties of complete dentures.

    Science.gov (United States)

    Yu, Sang-Hui; Cho, Hye-Won; Oh, Seunghan; Bae, Ji-Myung

    2015-06-01

    No study has yet evaluated the strength of complete dentures reinforced with glass fiber meshes with different content and structures. The purpose of this study was to compare the reinforcing effects of glass fiber mesh with different content and structures with that of metal mesh in complete dentures. Two types of glass fiber mesh were used: SES mesh (SES) and glass cloth (GC2, GC3, and GC4). A metal mesh was used for comparison. The complete dentures were made by placing the reinforcement 1 mm away from the tissue surface. A control group was prepared without any reinforcement (n=10). The compressive properties were measured by a universal testing machine at a crosshead speed of 5 mm/min. The results were analyzed with the Kruskal-Wallis test and the Duncan multiple range test (α=.05). The fracture resistance of the SES group was significantly higher than that of the control, GC4, and metal groups (asymptotic P=.004), but not significantly different from the GC2 and GC3 groups. The toughness of the SES and GC3 groups was significantly higher than that of the others (asymptotic Pglass fiber mesh seemed more important than the structures. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. The influence of double flask investing on tooth displacement in dentures processed by microwave irradiation.

    Science.gov (United States)

    Farias Neto, Arcelino; Sousa, Rodrigo L dos Santos; Rizzatti-Barbosa, Célia M

    2012-06-01

    This study evaluated the influence of the bimaxillary flask (BMF) and two different investing materials on first molar inclination in dentures processed by microwave irradiation. The BMF may minimise tooth displacement, saving time and improving occlusion. Forty pairs of dentures were randomised into four groups: stone wall in monomaxillary flask; silicone wall in BMF; stone wall in BMF; acrylic resin retentions and silicone in BMF. Dentures were processed by microwave irradiation. Two referential points were established on tooth surface. A microscope and a digital pachymeter were used to measure the distance between these points, and the angles α (right maxillary molar), β (left maxillary molar), α' (right mandibular molar) and β' (left mandibular molar) were calculated by the law of cosines. Data were submitted to Kruskal-Wallis (5% significance). No difference was observed among the groups (p > 0.05). In the intra-group analysis, α was significantly different for groups I, II and III; α', for groups II and IV; β, for all groups; β', for groups III and IV. First molar inclination was similar for monomaxillary and BMFs. The use of stone or silicone as investing materials presented the same effect on tooth inclination. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  17. A mandibular implant-supported fixed complete dental prosthesis in a patient with Sjogren syndrome: case report.

    Science.gov (United States)

    Spinato, Sergio; Soardi, Carlo Maria; Zane, Anna Maria

    2010-06-01

    The article describes the treatment and 1 year follow-up of a patient with Sjogren syndrome, treated with 6 intraforaminal mandibular implants with delayed loading and an implant-retained fixed prosthesis. The maxillary arch has been treated with a complete denture. This made an enormous difference in comfort and function for the patient. Radiographic check-ups did not reveal any peri-implant bone loss after 1 year of loading.

  18. Ex vivo fracture resistance of direct resin composite complete crowns with and without posts on maxillary premolars.

    NARCIS (Netherlands)

    Fokkinga, W.A.; Bell, A.M. Le; Kreulen, C.M.; Lassila, L.V.; Vallittu, P.K.; Creugers, N.H.J.

    2005-01-01

    AIM: To investigate ex vivo the fracture resistance and failure mode of direct resin composite complete crowns with and without various root canal posts made on maxillary premolars. METHODOLOGY: The clinical crowns of 40 human extracted single-rooted maxillary premolars were sectioned at the

  19. One-year results of maxillary overdentures supported by 2 titanium-zirconium implants - implant survival rates and radiographic outcomes.

    Science.gov (United States)

    Zembic, Anja; Tahmaseb, Ali; Jung, Ronald E; Wismeijer, Daniel

    2017-07-01

    To assess implant survival rates and peri-implant bone loss of 2 titanium-zirconium implants supporting maxillary overdentures at 1 year of loading. Twenty maxillary edentulous patients (5 women and 15 men) being dissatisfied with their complete dentures were included. In total, 40 diameter-reduced titanium-zirconium implants were placed in the anterior maxilla. Local guided bone regeneration (GBR) was allowed if the treatment did not compromise implant stability. Following 3 to 5 months of healing, implant-supported overdentures were inserted on two ball anchors. Implants and overdentures were assessed at 1, 2, 4, and 8 weeks after implant insertion and 2, 4, and 12 months after insertion of overdentures (baseline). Standardized radiographs were taken at implant loading and 1 year. Implant survival rates and bone loss were the primary outcomes. Nineteen patients (1 dropout) with 38 implants were evaluated at a mean follow-up of 1.1 years (range 1.0-1.7 years). One implant failed resulting in an implant survival rate of 97.3%. There was a significant peri-implant bone loss of the implants at 1 year of function (mean, 0.7 mm, SD = 1.1 mm; median: 0.48 mm, IQR = 0.56 mm). There was a high 1-year implant survival rate for edentulous patients receiving 2 maxillary implants and ball anchors as overdenture support. However, several implants exhibited an increased amount of bone loss of more than 2 mm. Overdentures supported by 2 maxillary implants should thus be used with caution as minimally invasive treatment for specific patients encountering problems with their upper dentures until more long-term data is available. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Efficacy of biofilm disclosing agent and of three brushes in the control of complete denture cleansing Eficácia de um evidenciador de biofilme e de três escovas no controle da higiene de próteses totais

    Directory of Open Access Journals (Sweden)

    Cláudia Helena Lovato da Silva

    2006-12-01

    Full Text Available OBJECTIVE: This report evaluated the efficacy of three brushes and one biofilm disclosing agent in complete denture cleansing. METHODS: Twenty-seven wearers of maxillary dentures were distributed into three groups and received different brushes: Oral B40, conventional toothbrush (Oral B; Denture, denture-specific brush (Condor; Johnson & Johnson, denture-specific brush (Johnson & Johnson. The 60-day experimental period was divided into two techniques: I - brushing (brush associated with a paste - Dentu Creme, Dentco three times a day; II - brushing and daily application of 1% neutral red on the denture internal surface. Biofilm quantification was carried out weekly and the areas with dye biofilm were obtained by means of Image Tool 2.02 software. RESULTS: Biofilm removal was more effective during Technique II (Wilcoxon test: p=0.01 for the three groups of brushes. When the brushes were compared in Technique I, the Kruskal Wallis test indicated statistical difference between Denture X Johnson & Johnson and Denture X Oral B40, in which the Denture was more efficient. For Technique II, there was no statistical difference between brushes (p>0.05. CONCLUSION: The disclosed application promoted more efficacy on biofilm removal, regardless of the brush used. Denture (Condor was more efficient than the other brushes during Technique I.Este trabalho avaliou três escovas e um evidenciador de biofilme na higiene de próteses totais. Vinte e sete usuários de próteses totais superiores foram distribuídos em três grupos que receberam diferentes escovas: Oral B40 para dentes naturais (Oral B; Denture para dentadura (Condor e Johnson & Johnson para dentadura (Johnson & Johnson. O período experimental de 60 dias foi dividido em 2 Técnicas: I - utilização das escovas associadas a um dentifrício (Dentu-Creme, Dentco três vezes ao dia; II - escovação e aplicação diária do evidenciador Vermelho neutro a 1% na superfície interna da prótese total. A

  1. Masseter muscle fatigue during sustained clenching in subjects with complete dentures, implant-supported prostheses, and natural teeth.

    Science.gov (United States)

    Jacobs, R; van Steenberghe, D

    1993-03-01

    A sustained submaximal (50%) clenching effort was performed in four patient groups to establish whether implant-supported prosthetic reconstructions influence myoelectrical signal parameters. The first group consisted of patients with natural teeth in both jaws. The other three groups consisted of patients who were edentulous in both jaws: one group had complete dentures; one had an overdenture in the mandible on two implants connected by a bar; and the third had an implant-supported fixed prosthesis in either the maxilla or the mandible. Surface electromyography indicated an increased myoelectrical output level that paralleled a higher bite force level for implant-supported reconstructions compared with complete dentures. Power spectrum analysis revealed a downward shift of the mean power frequency during sustained clenching in all groups except the implant-supported fixed prosthesis. The absence of a spectral shift in the latter group probably reflected a fear of biting too hard and fracturing the prosthesis.

  2. Transition from failing dentition to complete-arch implant rehabilitation with a staged approach: a 3-year clinical report.

    Science.gov (United States)

    Papaspyridakos, Panos; Chronopoulos, Vasilios

    2014-09-01

    The transition of patients from failing dentition to complete-arch implant rehabilitation often means that the patient is rendered edentulous and has to wear a removable complete denture for a time. Many patients find this objectionable. A staged treatment approach provides a fixed interim prosthesis for use throughout the rehabilitation process, allowing patient comfort and prosthodontic control. This clinical report describes a staged approach protocol with a new type of interim prosthesis. The prosthesis is supported by hopeless teeth and the soft tissues of the maxillary tuberosities and mandibular retromolar pads for the complete-arch implant rehabilitation of a patient with failing dentition. This protocol allows for a fixed interim prosthesis with combined tooth and mucosa or implant support during the entire rehabilitation process, thus avoiding the use of complete dentures. The implants and prostheses were functioning successfully after 3 years of clinical service. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Cost-effectiveness of silicone and alginate impressions for complete dentures.

    Science.gov (United States)

    Hulme, C; Yu, G; Browne, C; O'Dwyer, J; Craddock, H; Brown, S; Gray, J; Pavitt, S; Fernandez, C; Godfrey, M; Dukanovic, G; Brunton, P; Hyde, T P

    2014-08-01

    The aim of this study was to assess the cost effectiveness of silicone and alginate impressions for complete dentures. Cost effectiveness analyses were undertaken alongside a UK single centre, double blind, controlled, crossover clinical trial. Taking the perspective of the healthcare sector, effectiveness is measured using the EuroQol (EQ-5D-3L) which provides a single index value for health status that may be combined with time to produce quality adjusted life years (QALYs); and Oral Health Impact Profile (OHIP-EDENT). Incremental cost effectiveness ratios are presented representing the additional cost per one unit gained. Mean cost was higher in the silicone impression group (£388.57 vs. £363.18). Negligible between-group differences were observed in QALY gains; the silicone group had greater mean OHIP-EDENT gains. The additional cost using silicone was £3.41 per change of one point in the OHIP-EDENT. The silicone group was more costly, driven by the cost of materials. Changes in the EQ-5D and QALY gains over time and between arms were not statistically significant. Change in OHIP-EDENT score showed greater improvement in the silicone group and the difference between arms was statistically significant. Given negligible QALY gains and low level of resource use, results must be treated with caution. It is difficult to make robust claims about the comparative cost-effectiveness. Silicone impressions for complete dentures improve patients' quality of life (OHIP-EDENT score). The extra cost of silicone impressions is £30 per patient. Dentists, patients and health care funders need to consider the clinical and financial value of silicone impressions. Different patients, different dentists, different health funders will have individual perceptions and judgements. ISRCTN01528038. NIHR-RfPB grant PB-PG-0408-16300. This article forms part of a project for which the author (TPH) won the Senior Clinical Unilever Hatton Award of the International Assocation for Dental

  4. Single dental implant retained mandibular complete dentures – influence of the loading protocol: study protocol for a randomized controlled trial

    Science.gov (United States)

    2014-01-01

    Background Over the years, there has been a strong consensus in dentistry that at least two implants are required to retain a complete mandibular denture. It has been shown in several clinical trials that one single median implant can retain a mandibular overdenture sufficiently well for up to 5 years without implant failures, when delayed loading was used. However, other trials have reported conflicting results with in part considerable failure rates when immediate loading was applied. Therefore it is the purpose of the current randomized clinical trial to test the hypothesis that immediate loading of a single mandibular midline implant with an overdenture will result in a comparable clinical outcome as using the standard protocol of delayed loading. Methods/design This prospective nine-center randomized controlled clinical trial is still ongoing. The final patient will complete the trial in 2016. In total, 180 edentulous patients between 60 and 89 years with sufficient complete dentures will receive one median implant in the edentulous mandible, which will retain the existing complete denture using a ball attachment. Loading of the median implant is either immediately after implant placement (experimental group) or delayed by 3 months of submerged healing at second-stage surgery (control group). Follow-up of patients will be performed for 24 months after implant loading. The primary outcome measure is non-inferiority of implant success rate of the experimental group compared to the control group. The secondary outcome measures encompass clinical, technical and subjective variables. The study was funded by the Deutsche Forschungsgemeinschaft (German research foundation, KE 477/8-1). Discussion This multi-center clinical trial will give information on the ability of a single median implant to retain a complete mandibular denture when immediately loaded. If viable, this treatment option will strongly improve everyday dental practice. Trial registration The trial

  5. Alkaline Peroxides Versus Sodium Hypochlorite for Removing Denture Biofilm: a Crossover Randomized Trial.

    Science.gov (United States)

    Peracini, Amanda; Regis, Rômulo Rocha; Souza, Raphael Freitas de; Pagnano, Valéria Oliveira; Silva, Cláudia Helena Lovato da; Paranhos, Helena de Freitas Oliveira

    2016-01-01

    This study evaluated the efficacy of cleanser solutions on denture biofilm removal by a crossover randomized clinical trial. Thirty two edentulous patients were instructed to brush their dentures (specific brush and liquid soap) three times a day (after breakfast, lunch and dinner) and to soak them (≥ 8 h) in: (C) control -water; (AP): alkaline peroxide; or (SH) 0.5% sodium hypochlorite. Each solution was used for 21 days (three cycles of 7 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 - Sony). Areas (total and stained biofilm) were measured (Image Tool software) and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. Data were compared by means of generalized estimating equation (α=5%) and multiple comparisons (Bonferroni; α=1.67%). Immersion in SH reduced biofilm (%) (8.3 ± 13.3B) compared to C (18.2 ± 14.9A) and AP (18.2 ± 16.6A). The 0.5% sodium hypochlorite solution was the most efficacious for biofilm removal. Alkaline peroxides may not lead to further biofilm removal in patients with adequate denture maintenance habits.

  6. Effect of an intraoral retrusion plate on maxillary arch dimensions in complete bilateral cleft lip and palate patients

    NARCIS (Netherlands)

    Oosterkamp, B.C.; van Oort, R.P.; Dijkstra, P.U.; Stellingsma, K.; Bierman, M.W.; de Bont, L.G.

    Objective: The aim of this study was to analyze maxillary arch dimensions in patients with complete bilateral cleft lip and palate treated with an intraoral retrusion plate prior to lip closure. Patients: The effects of the intraoral retrusion plate were evaluated on serially obtained maxillary

  7. Evaluation of Oral Stereognostic Ability After Rehabilitating Patients with Complete Dentures: In Vivo Study

    OpenAIRE

    Meenakshi, S.; Gujjari, Anil Kumar; Thippeswamy, H. N.; Raghunath, N.

    2013-01-01

    Stereognosis has been defined as the appreciation of the form of objects by palpation. Whilst this definition holds good for the manual exploration of objects, it is possible for the shape of objects to be explored intra orally referred to as oral stereognosis. To better understand patients’ relative satisfaction with complete dentures, differences in oral stereognostic perception, based on the identification of 6 edible objects was analyzed in a group of 30 edentulous individuals at 3 stages...

  8. Changes in the edentulous maxilla with ball and telescopic attachments of implant-retained mandibular overdentures: a 4-year retrospective study.

    Science.gov (United States)

    Elsyad, Moustafa Abdou; Khairallah, Ahmed Samir; Shawky, Ahmad Fathalla

    2013-07-01

    This retrospective study investigated the clinical and radiographic changes in the edentulous maxilla in patients with either ball or telescopic attachments of implantretained mandibular overdentures. Thirty-two completely edentulous patients (21 males and 11 females) received two implants in the canine region of the mandible. New maxillary complete dentures and mandibular overdentures were fabricated. Overdentures were connected to the implants either with ball (group 1, n = 16) or telescopic (group 2, n = 16) attachments. Retention and stability of the maxillary denture as well as mucosal changes of the maxillary ridge were recorded after 4 years of denturewearing. Traced rotational tomograms were used for measurements of maxillary alveolar bone loss. The proportional value between bone areas and areas of reference not subject to resorption was expressed as a ratio (R). Change in R immediately before (T0) and after 4 years (T4) of overdenture insertion was calculated for the anterior and posterior regions of the maxilla. After 4 years of denture-wearing, maxillary denture retention was significantly higher in group 1 than in group 2, while occurrence of flabby ridges was significantly higher in group 2 than in group 1. The change in R of the anterior region of the maxilla was significantly higher than the change in the posterior region in both groups. Group 2 showed significant anterior residual ridge resorption compared to group 1. Telescopic attachments for implant-retained mandibular overdentures are associated with increased maxillary ridge resorption and flabbiness, and decreased maxillary denture retention when compared to ball attachments.

  9. Deep pain sensitivity is correlated with oral-health-related quality of life but not with prosthetic factors in complete denture wearers

    Directory of Open Access Journals (Sweden)

    Yuri Martins COSTA

    2015-12-01

    Full Text Available ABSTRACT Low pressure Pain Threshold (PPT is considered a risk factor for Temporomandibular Disorders (TMD and is influenced by psychological variables. Objectives To correlate deep pain sensitivity of masticatory muscles with prosthetic factors and Oral-Health-Related Quality of Life (OHRQoL in completely edentulous subjects. Material and Methods A total of 29 complete denture wearers were recruited. The variables were: a Pressure Pain Threshold (PPT of the masseter and temporalis; b retention, stability, and tooth wear of dentures; c Vertical Dimension of Occlusion (VDO; d Oral Health Impact Profile (OHIP adapted to orofacial pain. The Kolmogorov-Smirnov test, the Pearson Product-Moment correlation coefficient, the Spearman Rank correlation coefficient, the Point-Biserial correlation coefficient, and the Bonferroni correction (α=1% were applied to the data. Results The mean age (standard deviation of the participants was of 70.1 years (9.5 and 82% of them were females. There were no significant correlations with prosthetic factors, but significant negative correlations were found between the OHIP and the PPT of the anterior temporalis (r=-0.50, 95% CI-0.73 to 0.17, p=0.005. Discussion The deep pain sensitivity of masticatory muscles in complete dentures wearers is associated with OHRQoL, but not with prosthetic factors.

  10. Deep pain sensitivity is correlated with oral-health-related quality of life but not with prosthetic factors in complete denture wearers

    Science.gov (United States)

    COSTA, Yuri Martins; PORPORATTI, André Luís; HILGENBERG-SYDNEY, Priscila Brenner; BONJARDIM, Leonardo Rigoldi; CONTI, Paulo César Rodrigues

    2015-01-01

    ABSTRACT Low pressure Pain Threshold (PPT) is considered a risk factor for Temporomandibular Disorders (TMD) and is influenced by psychological variables. Objectives To correlate deep pain sensitivity of masticatory muscles with prosthetic factors and Oral-Health-Related Quality of Life (OHRQoL) in completely edentulous subjects. Material and Methods A total of 29 complete denture wearers were recruited. The variables were: a) Pressure Pain Threshold (PPT) of the masseter and temporalis; b) retention, stability, and tooth wear of dentures; c) Vertical Dimension of Occlusion (VDO); d) Oral Health Impact Profile (OHIP) adapted to orofacial pain. The Kolmogorov-Smirnov test, the Pearson Product-Moment correlation coefficient, the Spearman Rank correlation coefficient, the Point-Biserial correlation coefficient, and the Bonferroni correction (α=1%) were applied to the data. Results The mean age (standard deviation) of the participants was of 70.1 years (9.5) and 82% of them were females. There were no significant correlations with prosthetic factors, but significant negative correlations were found between the OHIP and the PPT of the anterior temporalis (r=-0.50, 95% CI-0.73 to 0.17, p=0.005). Discussion The deep pain sensitivity of masticatory muscles in complete dentures wearers is associated with OHRQoL, but not with prosthetic factors. PMID:26814457

  11. Effect of complete and partial removable dentures on chewing movements.

    Science.gov (United States)

    Gonçalves, T M S V; Vilanova, L S R; Gonçalves, L M; Rodrigues Garcia, R C M

    2014-03-01

    Partial or complete edentulism impairs mastication. However, it is unclear how the chewing cycle is affected by prosthetics. We evaluated the chewing movements of patients fitted with complete (CD) or removable partial denture (RPD). A total of 29 subjects were kinesiographically evaluated during chewing of peanuts and Optocal portions in a random sequence. The subjects were divided into two groups according to prosthesis type. Group RPD was composed of 14 partially edentulous patients using a lower distal extension RPD (mean age 61 ± 8 years), and group CD contained 15 completely edentulous patients using CD (mean age 65·9 ± 7·9 years) in both jaws. Opening, closing, occlusal and masticatory cycle times, movement angle (opening and closing), maximum velocity (opening and closing), total area and chewing cycle amplitudes were evaluated. The results were subjected to anova and Tukey's HSD test at a significance level of 5%. The RPD group exhibited shorter opening and closing phases and masticatory cycle time (P chewing envelope was smaller in the CD group (P chewing cycles in any of the parameters evaluated (P > 0·05). RPD wearers use a faster chewing sequence with greater vertical and lateral jaw excursions compared with CD wearers. © 2013 John Wiley & Sons Ltd.

  12. Clinical evaluation of failures in removable partial dentures.

    Science.gov (United States)

    Jorge, Janaina H; Quishida, Cristiane C C; Vergani, Carlos E; Machado, Ana L; Pavarina, Ana C; Giampaolo, Eunice T

    2012-01-01

    The aim of this clinical study was to evaluate the effects of removable partial dentures on the support tissues and changes occurring in lower tooth-supported and bilateral distal-extension dentures, 5 years after placement. The study involved analysis of a total of 53 patients who received prosthetic treatment for removable partial dentures. The patients were divided into two groups. In group 1, the patients had a completely edentulous maxilla and an edentulous area with natural teeth remaining in both the anterior and posterior regions. In group 2, the patients had a completely edentulous maxilla and partially edentulous mandible with preserved anterior teeth. Tooth mobility, prevalence of caries, fracture of the abutment teeth, fracture and/or deformation of the removable partial denture components and stability of the denture base were evaluated. The use of a removable partial denture increased tooth mobility, reduced the prevalence of caries, and did not cause loss or fracture of the abutments or damage to their components, when compared with the baseline. It was concluded that there was no difference between the groups as evaluated in terms of tooth mobility, prevalence of caries, loss and fracture of the abutments or damage to the components of the removable partial denture.

  13. Do traditional techniques produce better conventional complete dentures than simplified techniques? A 10-year follow-up of a randomized clinical trial.

    Science.gov (United States)

    Kawai, Yasuhiko; Muarakami, Hiroshi; Feine, Jocelyne S

    2018-07-01

    The use of a simplified method (S) of fabricating complete dentures has been shown to be more cost-efficient than the traditional method (T), and there are no negative consequences that detract from the cost savings in the short term. However, it is not clear whether this remains constant over a decade. The objective of this study was to clarify patients' perspectives and determine any differences between the dentures fabricated with these two different techniques after a decade of use. Edentate individuals participated in a randomized controlled clinical trial and completed a 6-month follow-up from 2001 to 2003 (T group n = 50; S group n = 54). For this 10-year follow-up, they were interviewed by telephone. The assessment included whether the denture was still in use or replaced, the condition of the dentures, patient satisfaction and oral health-related quality of life (OHRQoL). Between and within-group differences and the factors that cause deterioration of oral health-related quality of life (OHRQoL) were determined. Among 54 responders (25 T and 29 S), 14T and 21S kept the original dentures. Both groups were similar in ratings of satisfaction and OHRQoL (maxilla T: 80.0 S: 86.0, p = 0.36; mandibular; T: 66.1 S: 72.3, p = 0.48; OHRQoL T: 111.1 S: 108.5, p = 0.46). Irrespective of fabrication method, discomfort, chewing difficulty and esthetics were the factors that deteriorate OHRQoL (adjusted r = 0.76, p < 0.001). The results indicate that the simplified method remains more cost-efficient than the traditional method over a 10-year period. (IRB approval: A09-E71-12 B McGill University, trial registry: ClinicalTrial.org; NCT02289443). Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Do CAD/CAM dentures really release less monomer than conventional dentures?

    Science.gov (United States)

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  15. Denture quality has a minimal effect on health-related quality of life in patients with removable dentures.

    Science.gov (United States)

    Inoue, M; John, M T; Tsukasaki, H; Furuyama, C; Baba, K

    2011-11-01

    The present study examined the association of denture quality and health-related quality of life (HRQoL) in patients with removable dentures. In a study of 171 consecutive patients with removable partial dentures or complete dentures (mean age: 68·0 ± 9·3 years) at a university-based prosthodontic clinic, dentists rated two aspects of denture quality (stability and aesthetics) using a 100-mm visual analog scale (VAS). HRQoL was evaluated using the mental and physical component summary (MCS and PCS) scores of the Medical Outcomes Study Short-Form 36-Item Health Survey (SF-36). Oral health-related quality of life (OHRQoL) was evaluated using the Oral Health Impact Profile-Japanese version (OHIP-J). The associations among denture quality, OHRQoL, and HRQoL were examined by linear regression models. Bivariable linear regression analyses revealed that denture stability was significantly associated with the SF-36 MCS [regression coefficient = 0·52 for a 10-unit increase in denture stability on a 0-100 VAS, 95% confidence interval (CI): 0·03-1·00, P = 0·04], but not with the PCS (0·11, 95% CI: -0·49 to 0·70). Denture aesthetics was not related to the PCS or the MCS (0·22, 95% CI: -0·44 to 0·88 or 0·07, 95%CI: -0·47 to 0·62). When OHIP-J was added to the regression model, this variable was substantially and significantly associated with the MCS and PCS summary scores; in addition, the regression coefficient for denture quality decreased in magnitude and was statistically nonsignificant in all analyses. The quality of removable dentures had a minimal effect on HRQoL in patients with removable dentures, and this association was mediated by OHRQoL. © 2011 Blackwell Publishing Ltd.

  16. The impact of complete denture making instructional videos on self-directed learning of clinical skills.

    Science.gov (United States)

    Kon, Haruka; Botelho, Michael George; Bridges, Susan; Leung, Katherine Chiu Man

    2015-04-01

    The aim of this research was to evaluate the effectiveness of a clinical instructional video with a structured worksheet for independent self-study in a complete denture program. 47 multilingual dental students completed a task by watching an instructional video with subtitles regarding clinical complete denture procedures. After completion, students evaluated their learning experience, and 11 students participated in focus group interviews to gain further insight. A mixed-methods approach to data collection and analysis provided descriptive statistical results and a grounded theory approach to coding identified key concepts and categories from the qualitative data. Over 70% of students had favorable opinions of the learning experience and indicated that the speed and length of the video were appropriate. Highly positive and conflicting negative comments regarding the use of subtitles showed both preferences for subtitles over audio and vice versa. The use of a video resource was considered valuable as the replay and review functions allowed better visualization of the procedures, which was considered a good recap tool for the clinical demonstration. It was also a better revision aid than textbooks. So, if the students were able to view these videos at will, they believed that videos supplemented their self-study. Despite the positive response, videos were not considered to replace live clinical demonstrations. While students preferred live demonstrations over the clinical videos they did express a realization of these as a supplemental learning material for self-study based on their ease of access, use for revision, and prior to clinical preparation. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  17. Effect of storage time and framework design on the accuracy of maxillary cobalt-chromium cast removable partial dentures

    Science.gov (United States)

    Viswambaran, M.; Sundaram, R. K.

    2015-01-01

    Statement of Problem: Inaccuracies in the fit of palatal major connectors may be related to distortion of the wax pattern due to prolonged storage time and faulty major connector design. Purpose: This in vitro study was carried out to find out the effect of storage time and major connector design on the accuracy of cobalt-chromium cast removable partial dentures (RPDs). Materials and Methods: A brass metal die with a Kennedy Class III, modification 1, the partially edentulous arch was used as a master die. Thirty-six refractory casts were fabricated from the master die. The refractory casts were divided into three groups (Group I: Anterior-posterior palatal bar, Group II: Palatal strap and Group III: Palatal plate) based on the design of maxillary major connector and subdivided into four groups (sub Group A: 01 h, sub Group B: 03 h, Sub Group C: 06 h, and sub Group D: 24 h) based on the storage time. For each group, 12 frameworks were fabricated. The influence of wax pattern storage time and the accuracy of the fit palatal major connector designs on the master die were compared. Casting defects (nodules/incompleteness) of the frameworks were also evaluated before finishing and polishing. Repeated measures analysis of variance was used to analyze the data. Results: The gap discrepancy was least in sub Group A (01 h) followed by sub Group B (03 h) and C (06 h) and most in sub Group D (24 h). Statistically significant differences (P < 0.05 in all locations L1–L5) in the fit of the framework were related to the design of the major connector. The gap discrepancy was least in Group I (anterior-posterior palatal bar) followed by Group II (palatal strap) and most in Group II (palatal plate). Conclusions: It is recommended that the wax patterns for RPD to be invested immediately on completion of the wax procedure. The selection of a major connector design is crucial for an accurate fit of RPD. PMID:26681850

  18. Effect of storage time and framework design on the accuracy of maxillary cobalt-chromium cast removable partial dentures

    Directory of Open Access Journals (Sweden)

    M Viswambaran

    2015-01-01

    Full Text Available Statement of Problem: Inaccuracies in the fit of palatal major connectors may be related to distortion of the wax pattern due to prolonged storage time and faulty major connector design. Purpose: This in vitro study was carried out to find out the effect of storage time and major connector design on the accuracy of cobalt-chromium cast removable partial dentures (RPDs. Materials and Methods: A brass metal die with a Kennedy Class III, modification 1, the partially edentulous arch was used as a master die. Thirty-six refractory casts were fabricated from the master die. The refractory casts were divided into three groups (Group I: Anterior-posterior palatal bar, Group II: Palatal strap and Group III: Palatal plate based on the design of maxillary major connector and subdivided into four groups (sub Group A: 01 h, sub Group B: 03 h, Sub Group C: 06 h, and sub Group D: 24 h based on the storage time. For each group, 12 frameworks were fabricated. The influence of wax pattern storage time and the accuracy of the fit palatal major connector designs on the master die were compared. Casting defects (nodules/incompleteness of the frameworks were also evaluated before finishing and polishing. Repeated measures analysis of variance was used to analyze the data. Results: The gap discrepancy was least in sub Group A (01 h followed by sub Group B (03 h and C (06 h and most in sub Group D (24 h. Statistically significant differences (P < 0.05 in all locations L1–L5 in the fit of the framework were related to the design of the major connector. The gap discrepancy was least in Group I (anterior-posterior palatal bar followed by Group II (palatal strap and most in Group II (palatal plate. Conclusions: It is recommended that the wax patterns for RPD to be invested immediately on completion of the wax procedure. The selection of a major connector design is crucial for an accurate fit of RPD.

  19. Changes in head and cervical-spine postures and EMG activities of masticatory muscles following treatment with complete upper and partial lower denture.

    Science.gov (United States)

    Salonen, M A; Raustia, A M; Huggare, J A

    1994-10-01

    A clinical stomatognathic, cephalometric and electromyographic (EMG) study was performed in relation to 14 subjects (10 women, 4 men), each with an edentulous maxilla and residual mandibular dentition before and six months after treatment with complete upper and partial lower dentures. The mean age of the subjects was 54.4 years (range 43-64 years). The mean period of edentulousness and age of dentures were 22.5 years (range 15-33 years) and 14.1 (range 1.5-30 years), respectively. Natural head position was recorded (using a fluid-level method) and measured from cephalograms. EMG activity was measured in relation to masseter and temporal muscles. A decrease in clinical dysfunction index was noted in 12 of 14 subjects (86%). There was no change in cervical inclination, but a slight extension of the head was noted after treatment. Rapid recovery of the masticatory muscles was reflected in increased EMG activity, especially when biting in the maximal intercuspal position. In cases of edentulous maxilla and residual mandibular anterior dentition, treatment with a complete upper and lower partial denture had a favorable effect on craniomandibular disorders and masticatory-muscle function.

  20. Flexible thermoplastic denture base materials for aesthetical removable partial denture framework.

    Science.gov (United States)

    Singh, Kunwarjeet; Aeran, Himanshu; Kumar, Narender; Gupta, Nidhi

    2013-10-01

    Conventional fixed partial dentures, implant supported Fixed Partial Dentures (FDPs) and removable partial dentures are the most common treatment modalities for the aesthetic and functional rehabilitation of partially edentulous patients. Although implants and FDP have certain advantages over removable partial dentures, in some cases, removable partial dentures may be the only choice which is available. Removable cast partial dentures are used as definitive removable prostheses when indicated, but location of clasps may affect aesthetics. So, when patient is concerned about aesthetics, flexible partial dentures which is aesthetically superior to flipper and cast partial dentures, may be considered. But for the success of flexible removable partial denture, proper diagnosis, treatment planning and insertion technique of this prosthesis is very important, which have been thoroughly described in this article.

  1. Does tooth loss have an emotional effect? A cross-sectional and comparative study on nondenture wearers and complete denture wearers

    Directory of Open Access Journals (Sweden)

    Md. Shakeel Anjum

    2017-01-01

    Full Text Available Introduction: Teeth play various functional and esthetic roles. As any part of the body, even teeth loss gives one the feeling of being handicapped showing a negative impact on emotions. Sometimes, few people think that having 32 teeth and losing a few among them will not make a difference. Aim: To assess and compare the emotional effects due to loss of natural teeth in complete denture wearers and nondenture wearers. Materials and Methods: A hospital-based survey was conducted on complete denture wearers and nondenture wearers who were attending the outpatient department in a dental hospital for 2 months using a pretested, self-administered questionnaire. Results: Among them who were surveyed, 65.75% agreed accepting the tooth loss is difficult, only 30.13% felt that loss of teeth affected their self-confidence (P = 0.094, about 80.82% reported that natural teeth loss affected their eating efficiency, and 57.53% of them found it difficult while speaking to others. There was a significant difference between denture wearers and nondenture wearers when asked whether loss of teeth affected their looks, eating efficiency, and speaking difficulties (P = 0.000. Conclusion: Even though the majority of them found it difficult in accepting tooth loss, it did not affect their self-confidence majorly; however, most of them found functional difficulties with loss of natural teeth.

  2. Effect of Attachment Type on Implant Strain in Maxillary Implant Overdentures: Comparison of Ball, Locator, and Magnet Attachments. Part 1. Overdenture with Palate.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Implant overdentures with attachments have been used in clinical practice and the effect of attachments on implant strain has been frequently reported. However, most studies have focused on mandibular overdentures; there are few reports on maxillary overdentures. The purpose of this study was to examine the influence of attachment type on implant strain in maxillary overdentures under various implant configurations. A maxillary edentulous model with implants and experimental overdentures were fabricated. Four strain gauges were attached to each implant, positioned in anterior, premolar, and molar areas. Three types of unsplinted attachments-ball, locator, and magnet-were set on the implants under various implant configurations. A vertical occlusal load of 98 N was applied through the mandibular complete denture, and implant strain was compared using the Kruskal-Wallis test. Ball attachments caused the greatest amount of strain, while magnet attachments caused the least amount under all conditions. For all attachments, two anterior implants caused significantly more strain than four implants (P magnet attachments are recommended to reduce implant stress. Using only two implants, especially two anterior implants, is not recommended regardless of attachment type.

  3. Prosthetic rehabilitation of edentulous patient with limited oral access: A clinical report

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar

    2012-01-01

    Full Text Available Microstomia may result from surgical treatment of orofacial neoplasms, cleft lips, maxillofacial trauma, burns, radiotherapy or scleroderma. A maximal oral opening that is smaller than the size of a complete denture can make prosthetic treatment challenging. This clinical report presents the prosthodontic management of a total edentulous patient with microstomia. Sectional mandibular and maxillary trays and foldable mandibular and maxillary denture were fabricated for the total edentulous patient.

  4. Flexible Thermoplastic Denture Base Materials for Aesthetical Removable Partial Denture Framework

    OpenAIRE

    Singh, Kunwarjeet; Aeran, Himanshu; Kumar, Narender; Gupta, Nidhi

    2013-01-01

    Conventional fixed partial dentures, implant supported Fixed Partial Dentures (FDPs) and removable partial dentures are the most common treatment modalities for the aesthetic and functional rehabilitation of partially edentulous patients. Although implants and FDP have certain advantages over removable partial dentures, in some cases, removable partial dentures may be the only choice which is available. Removable cast partial dentures are used as definitive removable prostheses when indicated...

  5. Pseudomembranous candidiasis in patient wearing full denture

    Directory of Open Access Journals (Sweden)

    Nurdiana Nurdiana

    2009-06-01

    Full Text Available Background: Oral candidiasis is a common opportunistic infection of the oral cavity caused by an overgrowth of Candida species, the commonest being Candida albicans. Candida albicans is a harmless commensal organism inhabiting the mouths but it can change into pathogen and invade tissue and cause acute and chronic disease. Dentures predispose to infection with Candida in as many as 65% of elderly people wearing full upper dentures. Purpose: The purpose of this case report is to discuss thrush in patient wearing full denture which rapidly developed. Case: This paper report a case of 57 year-old man who came to the Oral Medicine Clinic Faculty of Dentistry Airlangga University with clinical appearance of pseudomembranous candidiasis (thrush. Case Management: Diagnosis of this case is confirmed with microbiology examination. Patient was wearing full upper dentures, and from anamnesis known that patient wearing denture for 24 hours and he had poor oral hygiene. Patient was treated with topical (nystatin oral suspension and miconazole oral gel and systemic (ketoconazole antifungal. Patient also instructed not to wear his denture and cleaned white pseudomembrane on his mouth with soft toothbrush. Conclusion: Denture, habit of wearing denture for 24 hours, and poor oral hygiene are predisposing factors of thrush and it can healed completely after treated with topical and systemic antifungal.

  6. A first experience with digital complete overdentures

    Directory of Open Access Journals (Sweden)

    Salwa Omar Bajunaid

    2016-07-01

    Full Text Available The development of computer-aided design/computer-aided manufacturing systems for dentistry in the 1980s resulted in the successful fabrication of crowns, fixed dental prostheses, and superstructures for both natural teeth and dental implants. Today, this technology is available for constructing digitally designed and milled, completely removable dental prostheses. The procedure uses clinical and laboratory protocols that allow fabrication of completely removable prostheses within two clinical appointments. The aim of this clinical report is to present the author’s first experience with digital complete overdentures, the practicality of this technology, and patient feedback. Compared with conventional overdentures, the fit of the digital prostheses was improved because the cameo and flanges of the prostheses were nicely shaped and rolled, and this enhanced their stability and retention. Occlusion was also excellent. However, aesthetics in terms of the alignment, shape, and size of the maxillary overdenture teeth were inacceptable. Despite some of the drawbacks identified in our study, the use of removable digital dentures does provide excellent adaptation of the denture base and requires fewer clinic visits. We anticipate that the unsatisfactory aesthetic outcomes presented in this report can be corrected with more experience. We also believe that acquiring an in-house scanning machine would be beneficial. We highly recommend including this technique in dental school curriculums at both the undergraduate and graduate levels in order to keep students and residents up to date on the latest technology available.

  7. A first experience with digital complete overdentures.

    Science.gov (United States)

    Bajunaid, Salwa Omar

    2016-07-01

    The development of computer-aided design/computer-aided manufacturing systems for dentistry in the 1980s resulted in the successful fabrication of crowns, fixed dental prostheses, and superstructures for both natural teeth and dental implants. Today, this technology is available for constructing digitally designed and milled, completely removable dental prostheses. The procedure uses clinical and laboratory protocols that allow fabrication of completely removable prostheses within two clinical appointments. The aim of this clinical report is to present the author's first experience with digital complete overdentures, the practicality of this technology, and patient feedback. Compared with conventional overdentures, the fit of the digital prostheses was improved because the cameo and flanges of the prostheses were nicely shaped and rolled, and this enhanced their stability and retention. Occlusion was also excellent. However, aesthetics in terms of the alignment, shape, and size of the maxillary overdenture teeth were inacceptable. Despite some of the drawbacks identified in our study, the use of removable digital dentures does provide excellent adaptation of the denture base and requires fewer clinic visits. We anticipate that the unsatisfactory aesthetic outcomes presented in this report can be corrected with more experience. We also believe that acquiring an in-house scanning machine would be beneficial. We highly recommend including this technique in dental school curriculums at both the undergraduate and graduate levels in order to keep students and residents up to date on the latest technology available.

  8. Evaluation of oral stereognostic ability after rehabilitating patients with complete dentures: in vivo study.

    Science.gov (United States)

    Meenakshi, S; Gujjari, Anil Kumar; Thippeswamy, H N; Raghunath, N

    2014-12-01

    Stereognosis has been defined as the appreciation of the form of objects by palpation. Whilst this definition holds good for the manual exploration of objects, it is possible for the shape of objects to be explored intra orally referred to as oral stereognosis. To better understand patients' relative satisfaction with complete dentures, differences in oral stereognostic perception, based on the identification of 6 edible objects was analyzed in a group of 30 edentulous individuals at 3 stages, namely, just before (pre-treatment), 30 min after (30 min post-treatment) and 1 month after (1 month post-treatment) the insertion of new dentures. The time required to identify each object was recorded and the correctness of identification of each object was scored using oral stereognostic score. Descriptive statistics, Wilcoxon signed rank test, Spearman's rank correlation test, Pearson Chi square test was used to statistically analyze the data obtained. OSA scores was significantly increased 1 month post-treatment compared to 30 min post-treatment (p < 0.05). It was found that Oral stereognostic test is reliable for measuring patients' oral stereognostic perception and may be used as one of the clinical aids in appreciating the functional limitations imposed by the prostheses.

  9. A technique to stabilize record bases for Gothic arch tracings in patients with implant-retained complete dentures.

    Science.gov (United States)

    Raigrodski, A J; Sadan, A; Carruth, P L

    1998-12-01

    Clinicians have long expressed concern about the accuracy of the Gothic arch tracing for recording centric relation in edentulous patients. With the use of dental implants to assist in retaining complete dentures, the problem of inaccurate recordings, made for patients without natural teeth, can be significantly reduced. This article presents a technique that uses healing abutments to stabilize the record bases so that an accurate Gothic arch tracing can be made.

  10. Orbital Blowout Fracture with Complete Dislocation of the Globe into the Maxillary Sinus.

    Science.gov (United States)

    Wang, Joy Mh; Fries, Fabian N; Hendrix, Philipp; Brinker, Titus; Loukas, Marios; Tubbs, R Shane

    2017-09-29

    This rare case report describes the diagnosis and treatment of an isolated left-sided orbital floor fracture with a complete dislocation of the globe into the maxillary sinus and briefly discusses the indications of surgery and recovery for orbital floor fractures in general. Complete herniation of the globe through an orbital blow-out fracture is uncommon. However, the current case illustrates that such an occurrence should be in the differential diagnosis and should be considered, especially following high speed/impact injuries involving a foreign object. In these rare cases, surgical intervention is required.

  11. A double blind randomized clinical trial comparing lingualized and fully bilateral balanced posterior occlusion for conventional complete dentures.

    Science.gov (United States)

    Kawai, Yasuhiko; Ikeguchi, Nobuyuki; Suzuki, Asako; Kuwashima, Azusa; Sakamoto, Ryuji; Matsumaru, Yuichi; Kimoto, Suguru; Iijima, Morio; Feine, Jocelyne Sylvia

    2017-04-01

    A lingualized occlusion (LO) for complete dentures reduces lateral inferences and occlusal force contacts and direction; thus, LO is theorized to be more suitable for patients with compromised ridges than fully bilateral balanced articulation (FBBA). However, no studies have yet provided evidence to support LO in edentate patients with compromised alveolar ridges. The purpose of this study was to compare LO and FBBA in edentulous individuals with compromised ridges. Sixty edentulous individuals were randomly allocated into groups and received dentures with either LO or FBBA. Following delivery, several denture-related satisfaction variables were measured using 100mm visual analogue scales; oral health-related quality of life (OHRQoL) was also assessed using the Oral Health Impact Profile (OHIP). Sub-group analyses of the effect of moderate and severe mandibular bone loss were also carried out. No significant differences were detected between LO and FBBA with the primary outcome. At 6 months, participants with severely atrophied mandibles and FBBA rated their satisfaction with retention of mandibular dentures significantly lower than those with LO (median LO: 86, FBBA: 58.5, p=0.03). They also had significantly lower OHRQoL for the domain of Pain (median LO: 4, FBBA: 5, p=0.02). General satisfaction and total OHIP scores significantly improved between baseline and 6 months only for the LO subjects with severely atrophied mandibles (satisfaction: p=0.003, OHIP total score: p=0.0007). The results indicate that the LO occlusal scheme with hard resin artificial teeth is more efficient for patients with severely resorbed mandibular ridges. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Does a mandibular overdenture improve nutrient intake and markers of nutritional status better than conventional complete denture? A systematic review and meta-analysis

    Science.gov (United States)

    Yamazaki, Toru; Martiniuk, Alexandra LC; Irie, Koichiro; Sokejima, Shigeru; Lee, Crystal Man Ying

    2016-01-01

    Objectives The need for denture treatment in public health will increase as the population ages. However, the impact of dentures on nutrition, particularly overdenture treatment, remains unclear although the physical and psychological effects are known. We investigated whether treatment with a mandibular implant supported overdenture improves nutrient intake and markers of nutritional status better than a conventional complete denture in edentulous patients. Design Systematic review and meta-analysis. Methods Medline, EMBASE and the Cochrane Central Register of Controlled Trials were searched for eligible studies published up to April 2016. We included studies which compared the treatment effect of an overdenture to conventional denture on nutrition, in which primary outcomes included changes in intake of macronutrients and/or micronutrients and/or indicators of nutritional status. Two reviewers independently evaluated eligible studies and assessed the risk of bias. We used a fixed effects model to estimate the weighted mean difference (WMD) and 95% CI for change in body mass index (BMI), albumin and serum vitamin B12 between overdenture and conventional denture 6 months after treatment. Results Of 108 eligible studies, 8 studies involving 901 participants were included in the narrative appraisal. Four studies reported changes in markers of nutritional status and nutrient intake after treatment with a prosthetic, regardless of type. In a meta-analysis of 322 participants aged 65 years or older from three studies, pooled analysis suggested no significant difference in change in BMI between an overdenture and conventional denture 6 months after treatment (WMD=−0.18 kg/m2 (95% CI −0.52 to 0.16)), and no significant difference in change in albumin or vitamin B12 between the two treatments. Conclusions The modifying effect of overdenture treatment on nutritional status might be limited. Further studies are needed to evaluate the effectiveness and efficacy of

  13. Comparative evaluation of pressure generated on a simulated maxillary oral analog by impression materials in custom trays of different spacer designs: An in vitro study

    Directory of Open Access Journals (Sweden)

    Sakshi Chopra

    2016-01-01

    Full Text Available Introduction: Literature reveals that masticatory load on denture bearing tissues through complete dentures should be maximum on primary stress bearing areas and least on relief area in accordance with the histology of underlying tissues. A study to validate the existing beliefs was planned to compare the pressure on mucosa using selective pressure technique and minimal pressure technique, with the incorporation of two different impression materials utilizing the pressure sensors during secondary impression procedure. Materials and Methods: The study was performed using a maxillary analog. Three pressure sensors were imbedded in the oral analog, one in the mid palatine area and the other two in the right and left ridge crest. Custom trays of two different configurations were fabricated. The two impression materials tested were light body and zinc oxide eugenol. A total of 40 impressions were made. A constant weight of 1 kg was placed, and the pressure was recorded as initial and end pressures. Results: A significant difference in the pressure produced using different impression materials was found (P < 0.001. Light body vinyl polysiloxane produced significantly lesser pressure than zinc oxide eugenol impression materials. The presence of relief did affect the magnitude of pressure at various locations. Conclusion: All impression materials produced pressure during maxillary edentulous impression making. Tray modification is an important factor in changing the amount of pressure produced. The impression materials used also had a significant role to play on the pressures acting on the tissues during impression procedure. Clinical Implication: Light body VPS impression material may be recommended to achieve minimal pressure on the denture bearing tissues in both selective as well as minimal pressure techniques.

  14. Comparative analysis of unilateral removable partial denture and classical removable partial denture by using finite element method

    Directory of Open Access Journals (Sweden)

    Radović Katarina

    2010-01-01

    Full Text Available Introduction. Various mobile devices are used in the therapy of unilateral free-end saddle. Unilateral dentures with precise connectivity elements are not used frequently. In this paper the problem of applying and functionality of unilateral freeend saddle denture without major connector was taken into consideration. Objective. The aim was to analyze and compare a unilateral RPD (removable partial denture and a classical RPD by calculating and analyzing stresses under different loads. Methods. 3D models of unilateral removable partial denture and classical removable partial denture with casted clasps were made by using computer program CATIA V5 (abutment teeth, canine and first premolar, with crowns and abutment tissues were also made. The models were built in full-scale. Stress analyses for both models were performed by applying a force of 300 N on the second premolar, a force of 500 N on the first molar and a force of 700 N on the second molar. Results. The Fault Model Extractor (FME analysis and calculation showed the complete behavior of unilateral removable partial denture and abutments (canine and first premolar, as well as the behavior of RPD under identical loading conditions. Applied forces with extreme values caused high stress levels on both models and their abutments within physiological limits. Conclusion. Having analyzed stresses under same conditions, we concluded that the unilateral RPD and classical RPD have similar physiological values.

  15. Influence of denture adhesives on occlusion and disocclusion times.

    Science.gov (United States)

    Abdelnabi, Mohamed Hussein; Swelem, Amal Ali; Al-Dharrab, Ayman A

    2016-03-01

    The effectiveness of adhesives in enhancing several functional aspects of complete denture performance has been well established. The direct influence of adhesives on occlusal contact simultaneity has not yet been investigated. The purpose of this crossover clinical trial was to evaluate quantitatively the influence of adhesives on occlusal balance by recording timed occlusal contacts; namely occlusion time (OT) and disocclusion time during right (DT-right) and left (DT-left) excursions by using computerized occlusal analysis. A crossover clinical trial was adopted. Assessments were carried out while participants (n=49) wore their dentures first without then with adhesives. Computerized occlusal analysis using the T-Scan III system was conducted to perform baseline computer-guided occlusal adjustment for conventionally fabricated dentures. Retention and stability assessment using the modified Kapur index and recording of OT and DT-right and DT-left values using the T-Scan III were subsequently carried out for all dentures, first without adhesives and then after application of adhesive. All T-Scan procedures were carried out by the same clinician. Wilcoxon signed-rank test was used to analyze the Kapur index scores and occlusal parameters (α=.05). Stability and retention of conventional dentures ranged initially from good to very good. However, adhesive application resulted in significant improvement (PAdhesives significantly decreased OT and DT durations in initially well-fitting complete dentures with fairly well balanced occlusion, and further enhanced denture stability and occlusal contact simultaneity. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Influence of the width and cross-sectional shape of major connectors of maxillary dentures on the accuracy of speech production.

    Science.gov (United States)

    Wada, Junichiro; Hideshima, Masayuki; Inukai, Shusuke; Matsuura, Hiroshi; Wakabayashi, Noriyuki

    2014-01-01

    To investigate the effects of the width and cross-sectional shape of the major connectors of maxillary dentures located in the middle area of the palate on the accuracy of phonetic output of consonants using an originally developed speech recognition system. Nine adults (4 males and 5 females, aged 24-26 years) with sound dentition were recruited. The following six sounds were considered: [∫i], [t∫i], [ɾi], [ni], [çi], and [ki]. The experimental connectors were fabricated to simulate bars (narrow, 8-mm width) and plates (wide, 20-mm width). Two types of cross-sectional shapes in the sagittal plane were specified: flat and plump edge. The appearance ratio of phonetic segment labels was calculated with the speech recognition system to indicate the accuracy of phonetic output. Statistical analysis was conducted using one-way ANOVA and Tukey's test. The mean appearance ratio of correct labels (MARC) significantly decreased for [ni] with the plump edge (narrow connector) and for [ki] with both the flat and plump edge (wide connectors). For [çi], the MARCs tended to be lower with flat plates. There were no significant differences for the other consonants. The width and cross-sectional shape of the connectors had limited effects on the articulation of consonants at the palate. © 2015 S. Karger AG, Basel.

  17. Multidisciplinary approach to restoring anterior maxillary partial edentulous area using an IPS Empress 2 fixed partial denture: a clinical report.

    Science.gov (United States)

    Dundar, Mine; Gungor, M Ali; Cal, Ebru

    2003-04-01

    Esthetics is a major concern during restoration of anterior partial edentulous areas. All-ceramic fixed partial dentures may provide better esthetics and biocompatibility in the restoration of anterior teeth. This clinic report describes a multidisciplinary approach and treatment procedures with an IPS Empress 2 fixed partial denture to restore missing anterior teeth.

  18. Using Intraoral Scanning Technology for Three-Dimensional Printing of Kennedy Class I Removable Partial Denture Metal Framework: A Clinical Report.

    Science.gov (United States)

    Hu, Feng; Pei, Zhenhua; Wen, Ying

    2017-11-16

    Removable partial dentures (RPDs) are used to restore missing teeth and are traditionally fabricated using the lost-wax casting technique. The casting process is arduous, time-consuming, and requires a skilled technician. The development of intraoral scanning and 3D printing technology has made rapid prototyping of the RPD more achievable. This article reports a completed case of direct fabrication of a maxillary RPD metal framework (Kennedy Class I) using intraoral scanning and 3D printing techniques. Acceptable fit and satisfactory clinical outcome were demonstrated. Intraoral scanning and 3D printing for fabrication of the RPD metal framework is a useful alternative to conventional impression and casting techniques, especially for patients suffering from nasal obstruction or intolerance. © 2017 by the American College of Prosthodontists.

  19. Kinematics modeling and experimentation of the multi-manipulator tooth-arrangement robot for full denture manufacturing.

    Science.gov (United States)

    Zhang, Yong-de; Jiang, Jin-gang; Liang, Ting; Hu, Wei-ping

    2011-12-01

    Artificial teeth are very complicated in shape, and not easy to be grasped and manipulated accurately by a single robot. The method of tooth-arrangement by multi-manipulator for complete denture manufacturing proposed in this paper. A novel complete denture manufacturing mechanism is designed based on multi-manipulator and dental arch generator. Kinematics model of the multi-manipulator tooth-arrangement robot is built by analytical method based on tooth-arrangement principle for full denture. Preliminary experiments on tooth-arrangement are performed using the multi-manipulator tooth-arrangement robot prototype system. The multi-manipulator tooth-arrangement robot prototype system can automatically design and manufacture a set of complete denture that is suitable for a patient according to the jaw arch parameters. The experimental results verified the validity of kinematics model of the multi-manipulator tooth-arrangement robot and the feasibility of the manufacture strategy of complete denture fulfilled by multi-manipulator tooth-arrangement robot.

  20. Hybrid approach to fabrication of hollow internally weighted mandibular denture: A case report

    OpenAIRE

    Hazari, Puja; Mishra, Sunil Kumar

    2015-01-01

    Preservation of ridge dimensions is critical for denture success. For long the concept of an internally weighted denture, which suggested that gravity and the additional weight to the mandibular complete denture aids in prosthetic retention is widely accepted. However, excessive weight and pressure can accelerate bone resorption. Here, we describe a unique modification of internally weighted metal denture base for the resorbed mandibular ridge with an incorporated additional hollow section ov...

  1. Collation of chewing efficiency and dentures with diverse occlusal schemes

    Directory of Open Access Journals (Sweden)

    Vijay Kumar Peddinti

    2017-01-01

    Full Text Available Background: Rehabilitation of an edentulous patient nurtures satisfaction and this lies in the chewing ability provided by the prosthesis. Aim: To evaluate and compare the masticatory efficiencies of complete dentures with different occlusal schemes. Materials and Methods: Fourteen completely edentulous patients from the age group of 50-70 years were selected according to the inclusion criteria followed in this study. The dentures were made with three different occlusal schemes, i.e., anatomic occlusion without balancing, anatomic occlusion with balancing, and lingualized occlusion and stored in water till the date of denture insertion. Post-insertion instructions were given to the patients at the time of delivery of the dentures. Patients were recalled after seven days and then masticatory efficiency was performed. The test was performed using boiled peanuts and Sieve system. Statistical Analysis: One-way analysis of variance (ANOVA test and unpaired t-test were carried out. Results: The obtained masticatory efficiency values with anatomic occlusion without balancing, anatomic occlusion with balancing, and lingualized occlusion LO were analyzed using one-way ANOVA test and unpaired “t” test. The tests showed that lingualized scheme had highest masticatory efficiency. Conclusion: Within the scope of this study, it can be concluded that the masticatory efficiency will be generally higher in patients provided with complete dentures fabricated using the lingualized occlusal scheme.

  2. [A phd completed 10. Implant-supported removable partial -dentures in a Kennedy Class I-situation in the mandible].

    Science.gov (United States)

    Jensen-Louwerse, C

    2017-06-01

    Implant-supported removable partial dentures in the mandible often cause problems, which means that patients wear their dentures seldom if at all. A solution is to place implants that the dentures can be snapped onto. There is, however, no consensus about the best position of the implants in the mandible yet. In addition, it is worthwhile to balance the cost of treatment with its effectiveness. In a randomised cross-over clinical trial involving 30 patients with a shortened dental arch, the implant-supported removable partial denture in the mandible was evaluated based on the experience of the patient, mean time of wearing, chewing ability and the clinical and radiographic parameters in relation to 2 different implant positions: 2 in the pre-molar region or 2 in the molar region. The cost-effectiveness of both treatments was also evaluated. From the patient's point of view, the implant-supported removable partial dentures are best supported by implants placed in the molar region. The research also revealed, however, that significantly more bleeding occurred around implants placed in the molar region and from a clinical perspective placement in the pre-molar region would have preference. The cost-effectiveness of the treatment with an implant-supported removable partial denture depends on the choice of outcome measurement and monetary threshold.

  3. Masticatory performance and oral health-related quality of life before and after complete denture treatment.

    Science.gov (United States)

    Yamamoto, Saori; Shiga, Hiroshi

    2018-03-13

    To clarify the relationship between masticatory performance and oral health-related quality of life (OHRQoL) before and after complete denture treatment. Thirty patients wearing complete dentures were asked to chew a gummy jelly on their habitual chewing side, and the amount of glucose extraction during chewing was measured as the parameter of masticatory performance. Subjects were asked to answer the Oral Health Impact Profile (OHIP-J49) questionnaire, which consists of 49 questions related to oral problems. The total score of 49 question items along with individual domain scores within the seven domains (functional limitation, pain, psychological discomfort, physical disability, psychological disability, social disability and handicap) were calculated and used as the parameters of OHRQoL. These records were obtained before treatment and 3 months after treatment. Each parameter of masticatory performance and OHRQoL was compared before treatment and after treatment. The relationship between masticatory performance and OHRQoL was investigated, and a stepwise multiple linear regression analysis was performed. Both masticatory performance and OHRQoL were significantly improved after treatment. Furthermore, masticatory performance was significantly correlated with some parameters of OHRQoL. The stepwise multiple linear regression analysis showed functional limitation and pain as important factors affecting masticatory performance before treatment and functional limitation as important factors affecting masticatory performance after treatment. These results suggested that masticatory performance and OHRQoL are significantly improved after treatment and that there is a close relationship between the two. Moreover, functional limitation was found to be the most important factor affecting masticatory performance. Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  4. Positional change of the condylar heads after wearing complete denture on dental cone beam CT

    International Nuclear Information System (INIS)

    Lee, Bong Ho; Kim, Jae Duk; Chung, Chae Heon

    2008-01-01

    The aim of this study was to evaluate the change in the position of the mandibular condyle within articular fossa by a CBCT after wearing complete denture (CD). CBCT of 34 temporomandibular joints were taken from 9 male and 8 female patients with CB Mercuray TM (Hitachi, Japan) before and after wearing a CD for rehabilitation. Position of mandibular condyle within articular fossa at centric occlusion was evaluated with Vimplant2.0 TM (CyberMed, Korea) on the central parasagittal view and curved panoramic coronal view of the condylar head. A statistical evaluation was done with SPSS. The range of anteroposterior positional rate (AP) of condylar head within articular fossa was -16-5 and -10-12 respectively on the right and left sides. Before wearing CD, the AP rate showed discrepancy between right and left sides (p<0.05). After wearing CD, both condyles showed a tendency to decrease in posterior condylar position (right side; p<0.05). The average discrepancy between right and left side in mediolateral positional rate (MD) was 15.5 and 4.5 respectively before and after wearing CD. The improvement was observed in mediolateral relationship of both condylar heads after wearing CD (p<0.01). Before wearing CD, the average horizontal angle of long axis of condylar head was 79.6 ± 2.7 .deg. C and 80.1 ± 5.7 .deg. C respectively on the right and left sides. After wearing CD, both condyles were rotated in the same direction in average on axial plane. We observed with CBCT the significant clinical evidence in case of positional change of mandibular condyle after wearing complete denture.

  5. MASTICATION, PHONETICS AND ESTHETICS AS A FINAL RESULT OF PARTIAL OR COMPLETE DENTURE TREATMENT.

    Directory of Open Access Journals (Sweden)

    Kalina Georgieva

    2015-08-01

    Full Text Available Three target groups- dentists/ dental students, dental technicians and patients were asked to fill in an anonymous questionnaire about their satisfaction of the final results after prosthetic treatment with removable dentures using a scale from 1 to 5 (1- completely dissatisfied, 2-dissatisfied, 3-indifferent, 4-satisfied, 5-completely satisfied. The mean results (including colour, shape and size of artificial teeth, arrangement of front teeth, colour of artificial gums, phonetics, mastication, natural smile, enough space for tongue for all three groups of respondents were compared. Dental technicians (4,34 are more satisfied than dentists/dental students (3,62 and patients (3,53. A successful outcome of prosthetic treatment depends on one hand on the professional approach of the dental team and on the other hand on the patient’s motivation and cooperation. The predictive final results and realistic expectations lead to satisfaction of all participants in the treatment process.

  6. Guide-Plane Retention in Designing Removable Partial Dentures.

    Science.gov (United States)

    Mothopi-Peri, Matshediso; Owen, C Peter

    To compare the influence of abutment teeth guide planes and guiding surfaces on retention of a removable partial denture (RPD). Extracted teeth embedded into a maxillary cast in the first premolar and second molar positions simulated two bounded saddles. Acrylic resin RPDs were made with no guide planes, then with guide planes, then with guiding surfaces added to directly contact the guide planes. The maximum loads on removal from the cast were recorded. There was a significant increase in retention force of 1.6 times when only guide planes were present and of 10.2 times when guiding surfaces intimately contacted the guide planes. The retention of acrylic resin RPDs can be substantially increased by making their guiding surfaces intimately contact the guide planes of the teeth.

  7. Prevalence of removable partial dentures users treated at the Aracatuba Dental School-UNESP.

    Science.gov (United States)

    Pellizzer, Eduardo P; Almeida, Daniel Augusto de Faria; Falcón-Antenucci, Rosse M; Sánchez, Daniela Mayumi I K; Zuim, Paulo Renato J; Verri, Fellippo R

    2012-06-01

    The aim of this study was to evaluate the frequency of removable partial dentures (RPD) at the Aracatuba Dental School. The study was conducted by analysing 412 clinical history of patients attended at the RPD clinics in the period from 2000 to 2007. 412 charts were analysed: 148 (35.9%) men and 264 (64.1%) women. The mean age was 53.8 years (men) and 52.4 years (women). A total of 556 dentures were made; of these, 233 (41.90%) were maxillary and 323 (58.09%) were mandibular dentures. The most frequent Kennedy classification found was Class III (maxilla) and Class I (mandible). In the maxilla, 55% (126) of the major connectors were of the anterior-posterior palatal bar, while in the mandible, 64% (202) were the lingual bar. As regards the claps, 401 were circumferential and 318 were bar claps. The mean age of the patients was 52.9 years with higher prevalence of female patients; the most frequent Kennedy's classification was Class I in mandible and Class III in maxilla; the most common major connector was anterior-posterior palatal bar for maxilla and lingual bar for mandible; the circumferential clasps were the most common retainer used in both jaws. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  8. Accelerating effects of cellulase in the removal of denture adhesives from acrylic denture bases.

    Science.gov (United States)

    Harada-Hada, Kae; Mimura, Sumiyo; Hong, Guang; Hashida, Tatsumi; Abekura, Hitoshi; Murata, Hiroshi; Nishimura, Masahiro; Nikawa, Hiroki

    2017-04-01

    Studies of effective methods for the easy removal of denture adhesives from a denture base are not well represented in the literature. We previously assessed the removability of denture adhesives by immersing within denture cleaners, showing that some cleaners have a weak effect, insufficiently effective in daily use. In this study, we prepared a cellulase, as a potential component for denture adhesive removers, and we examined whether the addition of cellulase to denture cleaners is effective in the removal of cream denture adhesives. We prepared the cellulase Meicelase as one component for the liquefaction of denture adhesives. We used two denture cleaners and two cream adhesives. After the immersion of plates in sample solutions, we evaluated the area of the sample plate still covered with adhesives. Biofilm removal assay was also performed using denture cleaners containing cellulase. The addition of cellulase accelerated the removal of cream adhesives in immersion experiments to a rate faster than that of water and denture cleaners. However, it did not influence the removability of Candida albicans biofilms from acrylic resin specimens. Cellulase hastened the liquefaction of cream adhesives. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  9. Hypohidrotic ectodermal dysplasia with anodontia: A rare case-rehabilitation by prosthetic management

    Directory of Open Access Journals (Sweden)

    M Naveen Kumar

    2012-01-01

    Full Text Available Ectodermal dysplasia is a hereditary disorder characterized by developmental dystrophies of ectodermal derivatives- It is characterized by triad of signs comprising sparse hair, abnormal or missing teeth and inability to sweat. This case of 12-year-old boy with hypohidrotic ectodermal dysplasia and complete anodontia of both primary and permanent dentition is presented. Owing to the need for treatment at an early age for anodontia and due to the ill-formed maxillary and mandibular residual ridges, the prosthetic management can be difficult. Complete dentures with soft liners and hollow maxillary denture were provided to encourage normal psychological development and to improve the function of the stomatognathic system.

  10. Going Beyond the Conventional Approach - Liquid Supported Denture: A Case Report

    Directory of Open Access Journals (Sweden)

    Dipti S Shah

    2013-01-01

    Full Text Available Background: The concept of conditioning oral mucosa has gained momentum over the last few years. Different tissue conditioning materials and soft liners have been used for this purpose. But the limitations of these materials has led to the introduction of liquid-supported dentures, which is a newer alternative to conventional complete denture prosthesis in cases with inflamed tissues, atrophic and severely resorbed edentulous ridges. Liquid supported Denture consists of a base which is covered with a preshaped close fitting flexible foil containing a thin film of high viscosity liquid which cushions the underlying tissues. This case report describes fabrication of liquid-supported dentures for patients with compromised tissues.

  11. [Effects of removable partial dentures on the quality of life in people with shortened dental arches].

    Science.gov (United States)

    Armellini, D B; Heydecke, G; Witter, D J; Creugers, N H J

    2009-12-01

    In order to assess the enhanced value of removable partial dentures on the quality of life, patients at 2 university clinics were screened for the presence of complete or shortened dental arches. Those selected were assigned to 1 of 5 subgroups: 1) a shortened dental arch with all frontal teeth, 2) a shortened dental arch with one or more frontal diastemas, 3) a shortened dental arch with all frontal teeth, restored by a removable partial denture, 4) a shortened dental arch and several diastemas, restored by a removable partial denture, 5) a complete dental arch. The participants completed the Oral Health Impact Profile (OHIP-49) and the Short Form Health Survey (SF-36). Clinical data recorded were: whether any teeth were missing and if so which, whether or not these had been replaced by a removable partial denture, and the number of occluding pairs of (pre)molars. The results revealed that a shortenend dental arch has a certain impact on the quality of life. However, the participants only experienced benefits from a removable partial denture if the denture also replaced frontal teeth.

  12. ORAL INJURIES ASSOCIATED WITH THE USE OF COMPLETE ENTURE

    Directory of Open Access Journals (Sweden)

    Thanny de Paula Mascarenhas Barbosa

    2011-05-01

    Full Text Available Nowadays the complete denture still is a very used method of treatment in the rehabilitation of persons who lost their teeth. Oral lesions may occur due to the use of denture with deficiency in confection, or even an inadequate orientation of the patient by the dental surgeon about the use of the dentures and its cleaning. Among the oral lesions caused by the use of complete denture most frequent were the chronic atrophic candidiasis, chronic hyperplastic candidiasis, inflammatory fibrous hyperplasia, angular cheilitis, and traumatic ulceration. A neoplasic lesion wasn’t found associated with the use of dentures. This study aims to identify through a literature review of the prevalence of major diseases due to the use of complete dentures as well as their treatments.

  13. Denture Adhesives

    Science.gov (United States)

    ... Devices Products and Medical Procedures Dental Devices Denture Adhesives Share Tweet Linkedin Pin it More sharing options ... Wearers Reporting Problems to the FDA Background Denture adhesives are pastes, powders or adhesive pads that may ...

  14. Magnet retained cheek plumper in complete denture esthetics: a case report.

    Directory of Open Access Journals (Sweden)

    Suryakant Chhagan Deogade

    2014-02-01

    Full Text Available This clinical report describes a technique to improve support for sunken cheeks using magnet retained detachable acrylic cheek plumpers. The new generation of magnets with improved technology provides sufficient denture retention for clinical application. However, further follow-up may be necessary to ascertain the long-term usefulness of the magnet-retained prosthesis, because of corrosion and further loss of magnetism.

  15. [Acrylic resin removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Creugers, N H J

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of removable partial dentures, the acrylic resin removable partial denture has 3 favourable aspects: the economic aspect, its aesthetic quality and the ease with which it can be extended and adjusted. Disadvantages are an increased risk of caries developing, gingivitis, periodontal disease, denture stomatitis, alveolar bone reduction, tooth migration, triggering of the gag reflex and damage to the acrylic resin base. Present-day indications are ofa temporary or palliative nature or are motivated by economic factors. Special varieties of the acrylic resin removable partial denture are the spoon denture, the flexible denture fabricated of non-rigid acrylic resin, and the two-piece sectional denture. Furthermore, acrylic resin removable partial dentures can be supplied with clasps or reinforced by fibers or metal wires.

  16. [Treatment of removable partial dentures. 2. Causes and consequences of a reduced occlusal system].

    Science.gov (United States)

    Witter, D J; Barèl, J C; de Baat, C; Keltjens, H M A M; Creugers, N H J

    2011-01-01

    The occlusal system is part of the orofacial system and consists of the maxillary and mandibular alveolar ridge and teeth which are occluding or not or the removable denture teeth. The most prevalent causes of loss of teeth are insufficient oral self care or inadequate professional oral healthcare service. A reduced dentition can be described in terms of diastemas in the anterior region and number of occluding pairs of (pre)molars, differentiated as interrupted or shortened dental arches. Characteristic of a healthy functional occlusal system are the absence of pathology and the possibility to practice all oral functions without inconvenience. The consequences of a reduced occlusal system may be overload and/or migration of teeth, mandibular instability, and impaired esthetics and chewing function. Morphological and functional alterations can be considered to be adaptations to changed situations or to be pathological. The distinction between adaptation and pathology cannot be sharply defined. If prosthetic replacement of teeth is needed, the trend is to avoid removable partial dentures.

  17. Effects of denture maintenance on satisfaction levels of Taiwanese elderly using removable partial dentures: a pilot study.

    Science.gov (United States)

    Wu, Ju-Hui; Yang, Yi-Hsin; Wang, Chau-Hsiang; Lee, Huey-Er; Du, Je-Kang

    2012-06-01

    The aim of this study was to evaluate the correlation between patient satisfaction with removable partial dentures and denture maintenance by patients, including regular application of denture adhesives and cleansers. The success of removable partial dentures depends on patient satisfaction with dentures and their regular denture maintenance. Demographic information, the Oral Impacts on Daily Performance (OIDP) indicator and details of denture maintenance (including the use of denture cleansers and adhesives) were collected from 193 (41.5% men and 58.5% women) participants by using questionnaires. A dentist performed oral examinations to evaluate denture function according to the OIDP items photographically and recorded the number of remaining teeth and Kennedy's classification. Most participants were satisfied with their removable partial dentures and tended to have higher satisfaction levels than the dentist's estimation. Further, those using denture adhesives and cleansers had higher satisfaction levels than those not using such denture maintenance. Appropriate education regarding denture use is important because regular denture maintenance by patients affects their degree of satisfaction with dentures, as well as the dentist's skill and the patient's oral condition. Dentists could use this information to predict the potential success of dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  18. A survey of U.S. prosthodontists and dental schools on the current materials and methods for final impressions for complete denture prosthodontics.

    Science.gov (United States)

    Petrie, Cynthia S; Walker, Mary P; Williams, Karen

    2005-12-01

    The purpose of this study was to survey members of The American College of Prosthodontists (ACP) to evaluate current materials and methods for final impressions for complete denture prosthodontics in the United States. In addition, those methods were compared with methods and materials taught in U.S. dental schools via a second survey sent to the chairpersons of prosthodontic/restorative departments. An anonymous questionnaire was mailed to all 1762 active ACP members in the United States in 2003. A slightly modified questionnaire was also distributed to chairpersons of prosthodontic/restorative departments in the 54 U.S. dental schools. Data analysis was performed via frequency distribution and chi-square statistics. Nine hundred and forty-five questionnaires were returned by members of the ACP (54% return rate) and 42 questionnaires were returned by the U.S. dental schools (78% return rate). The majority of the reporting prosthodontists (88%) and dental schools (98%) use a border-molded custom tray for final impressions for complete denture prosthodontics. The most popular material for border molding was plastic modeling compound (67% of reporting ACP members, and 95% of the responding dental schools). Variability of the materials used for final impressions was observed, with the most popular materials being polyvinylsiloxane for the ACP members (36%) and polysulfide for the dental schools (64%). Statistically significant differences were found in the materials used for border molding by prosthodontists based on the time elapsed since completion of prosthodontic training. No differences were found in the materials used for impression of edentulous arches based on years of experience. Geographic location did not influence the materials and methods used by prosthodontists for complete denture final impressions. There was variability of the materials and techniques used for final impressions by ACP members and dental schools; however, overall there was an agreement

  19. Poor oral hygiene, wearing dentures at night, perceptions of mouth dryness and burning, and lower educational level may be related to oral malodor in denture wearers.

    Science.gov (United States)

    Garrett, Neal R

    2010-03-01

    The study sample was recruited from edentulous patients seeking new dentures at the Kirikkale University Denture Clinic, Turkey. Male (n = 56) and female (n = 49) participants were enrolled and ranged from 50 to 78 years of age (mean age 60.7 6 7.7 years). All 105 completed baseline evaluations, new denture therapy, and follow-up examination approximately 4 weeks after denture treatment completion. The study was approved by the institution's Ethics Committee. Dates for patient recruitment and conduct of the study were not provided. For the prognostic component of the study, the primary factors of interest were sociodemographic characteristics, medical conditions previously related to oral malodor, and self-reported oral hygiene habits. The primary exposure for the interventional component was oral hygiene instruction, including brushing the tongue, cleaning the denture, and not wearing the denture at night. After treatment with new dentures, participants were instructed to follow these hygiene instructions daily and were evaluated 4 weeks later. The primary outcome measure was the degree of oral malodor with the original conventional dentures and following new denture treatment and oral hygiene instruction with 4 weeks of self-administered hygiene care. Oral malodor was expressed both quantitatively as the number of parts per billion (ppb) of volatile sulfide compounds (VSCs) and as a binary measure (present/absent) based on a threshold for oral malodor of greater than 110 ppb. Significant relationships with oral malodor (level of VSCs) at baseline with the original denture were found for education (those having only primary school education were more likely to have higher VSC level, odds ratio [OR] 8.6, P = .046), self-reported oral dryness (OR 2.5, P = .037), self-reported overnight denture wear (OR 0.342 [likely a typographical error in the table; based on the 95% CI of 1.59 to 8.35, the OR is probably 3.42], P = .002), and level of bacterial plaque coverage on

  20. Hybrid approach to fabrication of hollow internally weighted mandibular denture: A case report.

    Science.gov (United States)

    Hazari, Puja; Mishra, Sunil Kumar

    2015-08-01

    Preservation of ridge dimensions is critical for denture success. For long the concept of an internally weighted denture, which suggested that gravity and the additional weight to the mandibular complete denture aids in prosthetic retention is widely accepted. However, excessive weight and pressure can accelerate bone resorption. Here, we describe a unique modification of internally weighted metal denture base for the resorbed mandibular ridge with an incorporated additional hollow section over the anterior knife-edge ridge. The weight provided retention and stability while the hollow portion prevented further resorption of the bone.

  1. MICROECOLOGY OF THE MUCOUS MEMBRANE OF THE ALVEOLAR RIDGES IN THE PERIOD OF ADAPTATION TO COMPLETE DENTURES

    Directory of Open Access Journals (Sweden)

    Yanishen I. V.,

    2016-06-01

    Full Text Available Introduction. The oral cavity is an open ecosystem for various microorganisms and is one of the most populated biotopes of human. Removable dental prosthesis creates favorable conditions for the breeding of various microorganisms, including fungi. Stomatitis of dentition (SOD refers to a group of the most frequent pathologies of the mucous membranes of the oral cavity inflammatory character, due to the presence of the patient's dental prosthesis. For the prevention of SOD due to removable prostheses are used proper hygiene of dental prostheses, manufacture of technologically optimal designs of dentures, the shielding of the prosthesis and the use of cushioning materials. In this regard, the aim of this work was to study the dynamics characteristics of the microbiota of the mucous membranes of the oral cavity when performing prosthetic rehabilitation of patients with complete removable acrylic dentures with the use of adhesive and without its use. Materials and methods. The formation of the clinical groups of the patients occurred according to the following criteria: the study group comprised 23 patients with complete edentulous upper and lower jaw, which produced full removable laminar dentures on the upper and lower jaw, which used water-resistant adhesive based on polyvinylacetate and carboxymethilcellulose (cushions and/or cream "Fittydent" according to the instructions of the manufacturer, the control group consisted of 12 patients with complete edentulous upper and lower jaw, which produced full removable laminar dentures on the upper and lower jaw, in the period of adaptation to removable dentures has not applied the adhesive to improve the fixation of dentures. Microbiological examination of patients was carried out in dynamics before developing the prosthesis, after a week and after a month's stay of the prosthesis in the oral cavity. Results and discussion. Microbiological studies included determination of the qualitative and

  2. Managing the severely proclined maxillary anteriors by extracting traumatized right maxillary central incisor

    Directory of Open Access Journals (Sweden)

    Mahesh Jain

    2014-01-01

    Full Text Available A 14-year-old girl reported with severely proclined maxillary anterior teeth with fractured and discolored right maxillary central incisor with questionable prognosis. Autotransplantation of premolar to replace central incisor was considered a risky option as patient was 14-year-old with presence of advanced root development of premolar. The immediate placement of the prosthetic implant was also not possible because of patient′s age. Therefore, it was decided to use the space obtained by extracting questionable maxillary right central incisor for orthodontic purpose and also sacrificing the healthy premolar is invariably an excessive biological cost for a modest functional and aesthetic gain. Hence, the treatment plan for this case includes extraction of right maxillary central incisor and left maxillary first premolar, movement of right maxillary lateral incisor mesially, achieving normal axial inclination of maxillary anteriors with normal overjet and overbite. Mandibular arch was treated nonextraction due to congenitally missing central incisors with presence of normally inclined lower anteriors thereby maintaining Angles class I occlusion. Tipping, usually, seen in Begg mechanotherapy was used for our advantage to correct severely proclined maxillary anteriors with simultaneous bite opening mechanics. Case was completed in 19 months and posttreatment records including photographs, radiographs and study models were made. Begg wrap around the retainer was placed in the maxillary arch allowing natural settling of occlusion.

  3. Integrating hinge axis approximation and the virtual facial simulation of prosthetic outcomes for treatment with CAD-CAM immediate dentures: A clinical report of a patient with microstomia.

    Science.gov (United States)

    Kuric, Katelyn M; Harris, Bryan T; Morton, Dean; Azevedo, Bruno; Lin, Wei-Shao

    2017-09-29

    This clinical report describes a digital workflow using extraoral digital photographs and volumetric datasets from cone beam computed tomography (CBCT) imaging to create a 3-dimensional (3D), virtual patient with photorealistic appearance. In a patient with microstomia, hinge axis approximation, diagnostic casts simulating postextraction alveolar ridge profile, and facial simulation of prosthetic treatment outcome were completed in a 3D, virtual environment. The approach facilitated the diagnosis, communication, and patient acceptance of the treatment of maxillary and mandibular computer-aided design and computer-aided manufacturing (CAD-CAM) of immediate dentures at increased occlusal vertical dimension. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. The maxillary second molar - anatomical variations (case report).

    Science.gov (United States)

    Beshkenadze, E; Chipashvili, N

    2015-01-01

    To be acquainted with dental anatomical specificity is of great importance for dental endodontic treatment algorithm. The subject of present publication is 2 clinical cases of upper second molars, detailed characterization of, which is considered very important for enrichment of anatomical knowledge about dental anatomical variations. In one case, the reason for admission to the clinic of a 38-year-old woman was complains as of esthetic character as well as functional misbalance (disturbance of chewing function due to the damage of orthopedic construction). The patient indicated to the existence of coronary defects of large size aesthetic discomforts, damage and discolouration of old orthopedic construction (denture) in maxillary right molar area. According to the data obtained after clinical and visiographical examinations, chronic periodontitis of 17 teeth was identified as a result of incomplete endodontic treatment. According to the data obtained after clinical and visiographical examinations, the diagnosis of chronic periodontitis of 17 teeth was identified, tooth 17 with 2 roots and 2 canals. In the second clinical case, the reason for admission to the clinic of a 39-year-old woman was severe pain in the upper right molar area. The patient indicated to the caries on the tooth 17. After completion of proper survey clinical and visiographical examinations, acute pulpitis (K04.00) - with three roots and 4 canals was diagnosed. In both cases after the proper examinations and agreement with the patients a treatment plan envisaging: 17 teeth endodontic treatment, filling of caries defects and their preparation on one hand for orthopedic construction (denture) and on the other hand for restoration of anatomical integrity by light-cured composite, was scheduled. The present study is designed to prevent complications of endodontic treatment of the second molar, to optimize diagnosis and treatment algorithm, once again proving reliable information indicating to the

  5. Maxillary arch width in unoperated adult bilateral cleft lip and alveolus and complete bilateral cleft lip and palate.

    NARCIS (Netherlands)

    Latief, B.S.; Lekkas, C.; Kuijpers, M.A.R.

    2010-01-01

    OBJECTIVES: To study maxillary arch width in adult patients with bilateral cleft lip and alveolus (BCLA) or with complete bilateral cleft lip and palate (BCLP), who have not had any surgery. SETTING AND SAMPLING POPULATION: Eighteen patients with BCLA, 13 patients with BCLP, and 24 controls from

  6. [Evaluation of production and clinical working time of computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays for complete denture].

    Science.gov (United States)

    Wei, L; Chen, H; Zhou, Y S; Sun, Y C; Pan, S X

    2017-02-18

    To compare the technician fabrication time and clinical working time of custom trays fabricated using two different methods, the three-dimensional printing custom trays and the conventional custom trays, and to prove the feasibility of the computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays in clinical use from the perspective of clinical time cost. Twenty edentulous patients were recruited into this study, which was prospective, single blind, randomized self-control clinical trials. Two custom trays were fabricated for each participant. One of the custom trays was fabricated using functional suitable denture (FSD) system through CAD/CAM process, and the other was manually fabricated using conventional methods. Then the final impressions were taken using both the custom trays, followed by utilizing the final impression to fabricate complete dentures respectively. The technician production time of the custom trays and the clinical working time of taking the final impression was recorded. The average time spent on fabricating the three-dimensional printing custom trays using FSD system and fabricating the conventional custom trays manually were (28.6±2.9) min and (31.1±5.7) min, respectively. The average time spent on making the final impression with the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually were (23.4±11.5) min and (25.4±13.0) min, respectively. There was significant difference in the technician fabrication time and the clinical working time between the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually (Pmanufacture custom trays by three-dimensional printing method, there is no need to pour preliminary cast after taking the primary impression, therefore, it can save the impression material and model material. As to completing denture restoration, manufacturing custom trays using FSD system is worth being

  7. Denture plaque--past and recent concerns.

    Science.gov (United States)

    Nikawa, H; Hamada, T; Yamamoto, T

    1998-05-01

    This paper critically reviews the history of denture plaque and identifies some concerns with the presence of Candida in the mouth. This review covers literature sources related to Candida albicans and its relationship to denture plaque. The articles selected for this review are from referred journals and describe C. albicans and its relationship to oral, gastrointestinal and pleuropulmonary infections. The relationship to caries, root caries and periodontal disease is also covered. Denture plaque containing Candida could cause not only oral candidiasis, like oral thrush or denture-induced stomatitis, but also caries, root caries and periodontitis of abutment teeth. However, there is only limited experimental evidence or information available on the cariogenicity of Candida. The continuous swallowing or aspiration of micro-organisms from denture plaque exposes patients, particularly the immunocompromised host or medicated elderly, to the risks of unexpected infections. The term, 'denture plaque' has been used throughout the review. However, the term 'plaque on denture' should be used because the microbial flora and its pathogenicity of denture plaque resembles those of plaque formed on the tooth surface, so called dental plaque. In addition, the term 'denture related stomatitis' would be preferable to 'denture induced stomatitis', since the inflammation of (palatal) mucosa is not induced by the denture, but by wearing the denture or by plaque on the denture.

  8. Comparative evaluation of pressure generated on a simulated maxillary oral analog by impression materials in custom trays of different spacer designs: An in vitro study.

    Science.gov (United States)

    Chopra, Sakshi; Gupta, Narendra Kumar; Tandan, Amrit; Dwivedi, Ravi; Gupta, Swati; Agarwal, Garima

    2016-01-01

    Literature reveals that masticatory load on denture bearing tissues through complete dentures should be maximum on primary stress bearing areas and least on relief area in accordance with the histology of underlying tissues. A study to validate the existing beliefs was planned to compare the pressure on mucosa using selective pressure technique and minimal pressure technique, with the incorporation of two different impression materials utilizing the pressure sensors during secondary impression procedure. The study was performed using a maxillary analog. Three pressure sensors were imbedded in the oral analog, one in the mid palatine area and the other two in the right and left ridge crest. Custom trays of two different configurations were fabricated. The two impression materials tested were light body and zinc oxide eugenol. A total of 40 impressions were made. A constant weight of 1 kg was placed, and the pressure was recorded as initial and end pressures. A significant difference in the pressure produced using different impression materials was found (P changing the amount of pressure produced. The impression materials used also had a significant role to play on the pressures acting on the tissues during impression procedure. Light body VPS impression material may be recommended to achieve minimal pressure on the denture bearing tissues in both selective as well as minimal pressure techniques.

  9. Socio-Demographic and Economic Factors Affecting the Acceptance of Removable Dentures

    Science.gov (United States)

    Baran, İlgi; Ergün, Gülfem; Semiz, Mustafa

    2007-01-01

    Objectives The aim of this study was to evaluate relationships between the socio-demographic and economic factors of patients and the reasons of admission, usage periods of the two types of clinics, frequencies of denture changes, satisfaction levels and preferences of prosthetic dental treatment. Materials and Methods 510 partially and/or totally edentulous patients were studied using a questionnaire. The questionnaire consisted of questions; age, gender, education level, income status, problems with dentures, necessity for new dentures. Also asked was the place that the subjects would prefer to get their denture treatment, irrespective of their income level. In this study, Z-test was used to analyze two-sample proportions, T-test was used to determine two-sample means and Chi-square test was used to determine relationship between two classified variables. Results The number of male patients with complete dentures was more than the number of females, with an opposing trend for partial dentures. Irrespective of gender, each patient had had nearly two dentures by the time of questioning. It was also observed that the university clinics were generally preferred by patients from higher income levels with a higher educational level (x2=25.206, Pdenture treatment, regardless of cost, private practice was the preferred-choice. Conclusions With respect to dental condition and the acceptance of removable dentures, there were differences among gender, educational level and income status. PMID:19212485

  10. Wispy Prosthesis: A Novel Method in Denture Weight Reduction.

    Science.gov (United States)

    Anne, Gopinadh; Budeti, Sreedevi; Anche, Sampath Kumar; Zakkula, Srujana; Atla, Jyothi; Jyothula, Ravi Rakesh Dev; Appana, Krishna Chaitanya; Peddinti, Vijaya Kumar

    2016-04-01

    Stability and retention of the denture becomes at stake with the increase in weight of the denture prosthesis. As a consequence, different materials and methods have been introduced to overcome these issues but denture weight reduction still remains to be a cumbersome and strenuous procedure. To introduce a novel technique for the fabrication of denture prosthesis where in the weight of the denture will not affect the retention and stability of the denture. Four groups with a sample size of 10 each, were included where in one group was control and other three were study groups. The control group samples were made completely solid and the study group samples were packed with materials like bean balls, cellulose balls and polyacrylic fibers. The weight of all the samples of each study group was measured and compared with the control group. The observations were analyzed statistically by paired t-test. It was observed that the bean balls group produced a weight reduction of 31.3%, cellulose balls group 27.4% and polyacrylic fibers group 24.5% when compared to that of the control group. This novel technique will eliminate the problems that were associated in creating hollowness and at the same time will reduce the weight of the prosthesis and among all the study groups, bean balls group were found to reduce maximum weight of the prosthesis.

  11. CAD/CAM produces dentures with improved fit.

    Science.gov (United States)

    Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-02-22

    Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.

  12. The effect of various factors on the masticatory performance of removable denture wearer

    Science.gov (United States)

    Pratama, S.; Koesmaningati, H.; Kusdhany, L. S.

    2017-08-01

    An individual’s masticatory performance concerns his/her ability to break down food in order to facilitate digestion, and it therefore plays an important role in nutrition. Removable dentures are used to rehabilitate a loss of teeth, which could jeopardize masticatory performance. Further, there exist various other factors that can affect masticatory performance. The objective of this research is to analyze the relationship between various factors and masticatory performance. Thirty-four removable denture wearers (full dentures, single complete dentures, or partial dentures) participated in a cross-sectional study of masticatory performance using color-changeable chewing gum (Masticatory Performance Evaluating Gum Xylitol®). The volume of saliva was evaluated using measuring cups, while the residual ridge heights were measured using a modified mouth mirror no. 3 with metric measurements. The residual ridge height and removable-denture-wearing experience exhibited a significant relationship with masticatory performance. However, age, gender, saliva volume, denture type, and the number and location of the missing teeth did not have a statistically significant association with masticatory performance. The residual ridge height influences the masticatory performance of removable denture wearers, since the greater the ridge height, the better the performance. The experience of using dentures also has a statistically significant influence on masticatory performance.

  13. Biting Force and Muscle Activity in Implant-Supported Single Mandibular Overdentures Opposing Fixed Maxillary Dentition.

    Science.gov (United States)

    Al-Magaleh, Wafaʼa R; Abbas, Nadia A; Amer, Ashraf A; Abdelkader, Ann A; Bahgat, Basma

    2016-04-01

    This study aimed to investigate the relation between biting force and masticatory muscle activity in patients treated by 3 modalities of single mandibular dentures. Forty implants were placed in 10 patients with completely edentulous mandibles. The study was divided into 3 treatment stages. Initially, each patient received a conventional mandibular complete denture. At the second stage, 4 mandibular implants were placed and the denture was refitted to their abutments. Third stage comprised connecting the denture to the implants through ball attachments. During each treatment stage, maximum biting force and muscle activity were measured during maximum clenching and chewing of soft and hard food. Biting force demonstrated a statistically significant increase by time for the 3 treatment stages. The highest muscle activity was recorded for the conventional denture followed by the implant-supported overdenture without attachment, whereas the lowest values were recorded for the implant-supported overdenture with attachment. Biting force was related mainly to the quality of denture support. Muscle activity was higher in patients with conventional denture than with implant-supported prostheses (with or without attachments).

  14. [Removable partial dentures. Oral functions and types].

    Science.gov (United States)

    Creugers, N H J; de Baat, C

    2009-11-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic tissue-supported dentures, dentures with cast metal frameworks en dentures with cast metal frameworks and (semi)precision attachments. Interrupted tooth arches,free-ending tooth arches, and a combination of interrupted as well as free-ending tooth arches can be restored using these dentures. Well-known disadvantages of removable partial dentures are problematic oral hygiene, negative influence on the remaining dentition and limited oral comfort. Due to the advanced possibilities of fixed tooth- or implant-supported partial dentures, whether or not free-ending, or tooth- as well as implant-supported partial dentures, the indication of removable partial dentures is restricted. Nevertheless, for the time being the demand for removable partial dentures is expected to continue.

  15. Maxillary advancement using distraction osteogenesis with intraoral device.

    Science.gov (United States)

    Takigawa, Yoko; Uematsu, Setsuko; Takada, Kenji

    2010-11-01

    This article describes the surgical orthodontic treatment of maxillary hypoplasia in a patient with cleft lip and palate using maxillary distraction osteogenesis with internal maxillary distractors. Maxillary advancement was performed to correct the retrusive maxillary facial profile and Class III malocclusion. Rotational movement of the distraction segment was made to correct the upper dental midline. Although maxillary advancement was insufficient because of unexpected breakage of the intraoral distractor after completion of the distraction, skeletal traction with a face mask compensated for the shortage. Successful esthetic improvement and posttreatment occlusal stability were achieved with no discernible relapse after 2 years of retention.

  16. Surveys of Current Teaching and Practice for Impressions for Complete Dentures.

    Science.gov (United States)

    Hussain, N; Jabbar, H; Hayati, M; Wu, J; Hyde, T P

    2018-03-08

    The 3 objectives are to assess current preferences for impressions for complete dentures, audit practice and compare practice to current UK teaching. Three surveys where undertaken; a survey of GDPs preferences, an audit of practice and a survey of teaching in UK dental schools. UK Universities advocate border moulded custom trays. In stated preferences, 99% of practitioners used custom trays for private practice; 67% for NHS work. In actual use, the audit found 91% practitioners in private practice used custom trays; in NHS practice 78% did so. The most widely taught materials were silicone (43%), alginate (29%), & zinc oxide eugenol paste (19%). In practitioners stated preferences, 97% of NHS and 53% of private dentists listed alginate as an option; however the audit showed only 74% (NHS) and 52% (private) actually used alginate, with 20% (NHS) and 48% (private) using silicone. Definitive impressions in custom trays are used by GDPs for both private and NHS work; they are universally taught at UK dental schools. Alginate is popular in NHS practice; however, silicone is more widely taught in UK Universities. The use of silicone materials for definitive impressions has increased since 1999. In UK private practice silicone usage is aligned in popularity with alginate. Copyright© 2018 Dennis Barber Ltd.

  17. Swallowed dentures: Two cases and a review

    Directory of Open Access Journals (Sweden)

    Mahir Gachabayov

    2015-12-01

    Conclusion: Fixed dentures can be accidentally ingested as well as removable dentures. Denture loosening leads to accidental denture ingestion. Patients with denture loosening should be recommended to visit dentist as soon as possible.

  18. Correction of complete maxillary crossbite with severe crowding using Hyrax expansion and fixed appliance.

    Science.gov (United States)

    Wangsrimongkol, Tasanee; Manosudprasit, Montian; Pisek, Poonsak; Leelasinjaroen, Pornnapha

    2013-09-01

    An 18-year-old Thai man who presented with a secondary cleft palate, maxillary hypoplasia and severe crowding was treated by rapid maxillary expansion and fixed orthodontic appliances. Initial assessment found skeletal Class III malrelationship and dental Class II malocclusion with anterior and bilateral posterior crossbites. Camouflage orthodontic treatment was planned using a rapid maxillary expansion appliance and correcting crowding with extraction all four premolar teeth. A Hyrax appliance and vertical loop arch wire were placed for maxillary arch expansion of 9.5 mms at first molars and canines, and 5.5 mms at the premolars and obtained positive overjet. Both acceptable skeletal and soft tissue relationships and satisfactory occlusion were produced. After 14 months of postoperative follow-up, the occlusal result was stable and no skeletal reversals could be detected.

  19. Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Pramita Suwal

    2017-03-01

    Full Text Available Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05. The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05. The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05. Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p

  20. Effect of different curing temperatures on the distortion at the posterior peripheral seal: An in vitro study

    Directory of Open Access Journals (Sweden)

    Nirmala Pasam

    2012-01-01

    Conclusion: This study verified the observation that maxillary complete denture base show the greatest discrepancy at the central portion of the posterior palatal seal region as the processing temperature increases.

  1. Maxillary rehabilitation using fixed and removable partial dentures with attachments: a clinical report.

    Science.gov (United States)

    dos Santos Nunes Reis, José Maurício; da Cruz Perez, Luciano Elias; Alfenas, Bruna Fernandes Moreira; de Oliveira Abi-Rached, Filipe; Filho, João Neudenir Arioli

    2014-01-01

    Despite requiring dental crown preparation and possible root canal treatment, besides the difficulty of clinical and laboratory repairs, and financial burden, the association between fixed (FPD) and removable partial dentures (RPD) by means of attachments is an important alternative for oral rehabilitation, particularly when the use of dental implants and FPDs is limited or not indicated. Among the advantages of attachment-retained RPDs are the improvements in esthetics and biomechanics, as well as correction of the buccal arrangement of anterior teeth in Kennedy Class III partially edentulous arches. This article describes the treatment sequence and technique for the use of attachments in therapy combining FPD/RPD. © 2013 by the American College of Prosthodontists.

  2. [Removable partial dentures. Oral functions and types

    OpenAIRE

    Creugers, N.H.J.; Baat, C. de

    2009-01-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic tissue-supported dentures, dentures with cast metal frameworks en dentures with cast metal frameworks and (semi)precision attachments. Interrupted tooth arches,free-ending tooth arches, and a combinatio...

  3. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures

    Science.gov (United States)

    Creugers, N. H. J.; Witter, D. J.; Van 't Spijker, A.; Gerritsen, A. E.; Kreulen, C. M.

    2010-01-01

    Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n = 25) were compared with subjects with shortened dental arches without extension (n = 74) and with subjects who had worn a mandibular extension removable partial denture in the past (n = 19). Subjects with complete dentitions (n = 72) were controls. Data were collected at baseline and at 3-, 6-, and 9-year observations. Results. Occlusal activity in terms of reported awareness of bruxism and occlusal tooth wear of lower anterior teeth did not differ significantly between the groups. In contrast, occlusal tooth wear of premolars in shortened dental arches with or without extension dentures was significantly higher than in the controls. Differences amongst groups with respect to signs and symptoms related to temporomandibular disorders were not found. Occlusal support of the dentures did not influence anterior spatial relationship. Occlusal contacts of the denture teeth decreased from 70% for second premolars via 50% for first molars, to 30% for second molars. Conclusions. Mandibular distal extension removable partial dentures in moderate shortened dental arches had no effects on occlusion and temporomandibular function. PMID:20671961

  4. Prevalence of Candida spp. among healthy denture and nondenture wearers with respect to hygiene and age

    Directory of Open Access Journals (Sweden)

    Bharathi Prakash

    2015-01-01

    Full Text Available Dentures are inert and nonshading surfaces and therefore get easily colonized by Candida species. Subsequent biofilm produced by them lead to denture stomatitis and candidiasis. This study was aimed to understand the prevalence of Candida species among healthy denture and nondenture wearers with respect to their age and hygiene status. Swabs were collected from 50 complete dentures and 50 non-denture wearers and processed on Sabouraud′s dextrose agar. Identification of Candida species was done by staining and a battery of biochemical tests. Data obtained was correlated with age & oral hygiene and statistical analysis was performed. Candida was isolated from both denture and nondenture wearers. Prevalence of different Candida species was significantly higher in denture wearers and found predominated by C. albicans, C. tropicalis, C. dubliensis and C. glabrata. Among nondenture wearers, C. albicans and C. tropicalis were isolated. Prevalence of Candida increased with increasing age among denture wearers. Men presented declining denture hygiene compared to women with increasing age. In comparison to nondenture wearers, multispecies of Candida colonized the dentures thus presenting higher risk of candidiasis especially with increasing age.

  5. Immediate implant placement and provisional crown fabrication after a minimally invasive extraction of a peg-shaped maxillary lateral incisor: a clinical report.

    Science.gov (United States)

    Turkyilmaz, Ilser; Suarez, Jose Carlos; Company, Andrea M

    2009-09-01

    The aim of this case report is to describe the replacement of a maxillary peg-shaped lateral incisor with the placement of an immediate implant and a provisional restoration following a minimally invasive extraction to preserve anterior esthetics. Extraction sites in the anterior maxilla can present restorative challenges with regard to esthetics. Resistance to wearing a temporary removable partial denture during healing makes immediate implant therapy an appealing alternative to patients. Implant placement into fresh extraction sockets using no flap elevation has recently become more popular due to some advantages including less bleeding, swelling, and the preservation of existing soft tissue contours. A 20-year-old woman with a peg-shaped maxillary left lateral incisor was treated using an implant placed into the fresh extraction socket using a flapless approach and immediate provisional crown fabrication. Flapless implant placement helps to preserve site morphology by protecting and supporting existing hard and soft tissues while minimizing surgical trauma to the adjacent tissues. Using a previously fabricated acrylic index, a provisional acrylic crown was fabricated on the adjusted temporary abutment and delivered to the patient the same day during the extraction visit. This report describes the diagnosis and treatment of an over-prepared peg-shaped maxillary left lateral incisor associated with multiple crown decementations. The tooth was extracted without flap elevation and an implant was inserted immediately using flapless surgery and placement of an immediate provisional single crown. Flapless implant insertion into fresh extraction sockets and placement of immediate provisional crowns in cases involving the maxillary anterior region represent a viable treatment option in appropriate clinical situations where esthetics are a high priority. The strategy preserves optimum gingival contours and papillary height may be a viable option compared to fixed partial

  6. Management of bruxism-induced complications in removable partial denture wearers using specially designed dentures: a clinical report.

    Science.gov (United States)

    Baba, Kazuyoshi; Aridome, Kumiko; Pallegama, Ranjith Wasantha

    2008-01-01

    In patients with a limited number of remaining teeth, bruxism force can be destructive for both the remaining teeth and periodontal structures. This paper reports the successful management of four such patients with severe sleep bruxism, using conventional removable partial dentures and specially designed, splint-like removable partial dentures called a night denture. The night denture was fabricated in two different designs, which depended upon the pattern of the remaining tooth contacts. The patients were followed up for 2-6 years using a night denture in either of the two designs. Within the limitations of these four reports of clinical cases, the night denture appeared to be effective in managing the problems related to sleep bruxism.

  7. Denture Adhesives in Prosthodontics: An Overview.

    Science.gov (United States)

    Kumar, P Ranjith; Shajahan, P A; Mathew, Jyothis; Koruthu, Anil; Aravind, Prasad; Ahammed, M Fazeel

    2015-01-01

    The use of denture adhesives is common among denture wearers, and it is also prescribed by many dentists. Prescribing denture adhesives has been viewed by many prosthodontists as a means of compensating for any defects in the fabrication procedures. Denture adhesives add to the retention and thereby improve chewing ability, reduce any instability, provide comfort and eliminate the accumulation of food debris beneath the dentures. Consequently, they increase the patient's sense of security and satisfaction. However, obtaining the advice of the dental practitioner prior to the use of adhesives is a must.

  8. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base.

    Science.gov (United States)

    Shinawi, Lana Ahmed

    2017-05-01

    The application of computer-aided design computer-aided manufacturing (CAD CAM) technology in the fabrication of complete dentures, offers numerous advantages as it provides optimum fit and eliminates polymerization shrinkage of the acrylic base. Additionally, the porosity and surface roughness of CAD CAM resins is less compared to conventionally processed resins which leads to a decrease in the adhesion of bacteria on the denture base, which is associated with many conditions including halitosis and aspiration pneumonia in elderly denture wearers. To evaluate the influence of tooth brushing with dentifrices on CAD CAM resin blocks in terms of abrasion resistance, surface roughness and scanning electron photomicrography. This experimental study was carried out at the Faculty of Dentistry of King Abdulaziz University during 2016. A total of 40 rectangular shaped polymerized CAD CAM resin samples were subjected to 40.000 and 60.000 brushing strokes under a 200-gram vertical load simulating three years of tooth brushing strokes using commercially available denture cleaning dentifrice. Data were analyzed by SPSS version 20, using descriptive statistics and ANOVA. ANOVA test revealed a statistical significant weight loss of CAD CAM acrylic resin denture base specimens following 40.000 and 60.000 brushing strokes as well as a statistical significant change (p=0.0.5) in the surface roughness following brushing. The CAD CAM resin samples SEM baseline imaging revealed a relatively smooth homogenous surface, but following 40,000 and 60,000 brushing strokes, imaging displayed the presence of small scratches on the surface. CAD CAM resin displayed a homogenous surface initially with low surface roughness that was significantly affected following simulating three years of manual brushing, but despite the significant weight loss, the findings are within the clinically acceptable limits.

  9. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures

    Directory of Open Access Journals (Sweden)

    N. H. J. Creugers

    2010-01-01

    Full Text Available Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n=25 were compared with subjects with shortened dental arches without extension (n=74 and with subjects who had worn a mandibular extension removable partial denture in the past (n=19. Subjects with complete dentitions (n=72 were controls. Data were collected at baseline and at 3-, 6-, and 9-year observations. Results. Occlusal activity in terms of reported awareness of bruxism and occlusal tooth wear of lower anterior teeth did not differ significantly between the groups. In contrast, occlusal tooth wear of premolars in shortened dental arches with or without extension dentures was significantly higher than in the controls. Differences amongst groups with respect to signs and symptoms related to temporomandibular disorders were not found. Occlusal support of the dentures did not influence anterior spatial relationship. Occlusal contacts of the denture teeth decreased from 70% for second premolars via 50% for first molars, to 30% for second molars. Conclusions. Mandibular distal extension removable partial dentures in moderate shortened dental arches had no effects on occlusion and temporomandibular function.

  10. Implant retainers for free-end removable partial dentures affect mastication and nutrient intake.

    Science.gov (United States)

    Campos, Camila Heitor; Gonçalves, Thais Marques Simek Vega; Rodrigues Garcia, Renata Cunha Matheus

    2014-08-01

    This study measured swallowing threshold parameters and nutrient intake in partially dentate subjects rehabilitated by conventional free-end removable partial dentures (RPD) and by RPD over posterior implant retainers and ball attachments (BA). Eight subjects (two men and six women; mean age 60.1 ± 6.6 years old) received conventional total maxillary dentures and free-end RPD in the mandible. Two months after denture insertion, swallowing threshold and nutrient intake assessments occurred, which included an evaluation of the number of masticatory cycles and medium particle size (X₅₀) of a silicone test material (Optocal). A 3-day food diary verified nutrient intake based on a standard Brazilian Food Composition Table. Then, osseointegrated implants were placed bilaterally in the mandibular first molar region, followed by BA, which was fitted in the RPD bases after healing. After 2 months of the RPD over implants and BA use, variables were again assessed. Wilcoxon signed rank tests evaluated the data (P 0.05); however, subjects showed decreased X₅₀ values at the swallowing moment (P = 0.008) and increased daily energy (P = 0.008), carbohydrate (P = 0.016), protein (P = 0.023), calcium (P = 0.008), fiber (P = 0.016), and iron (P = 0.016) intake with RPD implants and BA inserts. No differences were found in fat consumption (P > 0.05). Implants and BA retainers over a free-end RPD resulted in smaller swallowed median particle size and improved nutrient intake. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  11. A radiographic template for a two-implant mandibular overdenture using the patient’s existing denture

    Science.gov (United States)

    Huynh-Ba, G; Alexander, P; Vargas, A; Vierra, M; Oates, TW

    2012-01-01

    This article introduces a technique for modifying an existing mandibular complete denture for use as a radiographic template with a radiopaque light-activated calcium hydroxide (Ca(OH)2) preparation. This allows prosthetically-driven treatment planning and surgical placement of 2 implants to support the existing mandibular denture. PMID:23328197

  12. Survival of various implant-supported prosthesis designs following 36 months of clinical function.

    Science.gov (United States)

    Rodriguez, A M; Orenstein, I H; Morris, H F; Ochi, S

    2000-12-01

    The use of endosseous dental implants to replace natural teeth lost to trauma, dental caries, or periodontal disease has become a predictable form of prosthetic treatment since gaining popularity in the early 1980s. While numerous clinical studies have focused on the survival of implants, few address the survival of different prosthesis designs. Beginning in 1991, 882 prostheses supported by more than 2,900 implants (687 patients) were placed by the Department of Veterans Affairs Dental Implant Clinical Research Group (DICRG). These prostheses were divided into five research strata based on arch location. The recommended design for each stratum was: bar-supported overdenture (maxillary completely edentulous); screw-retained hybrid denture (mandibular completely edentulous); screw-retained fixed partial denture (mandibular and maxillary posterior partially edentulous); and cemented single crown (maxillary anterior single tooth). Alternative overdenture designs were utilized in the edentulous arches when the recommended prosthesis could not be fabricated. Prosthesis success rates for the research strata were calculated for an observation time of up to 36 months following prosthesis placement. Success rates for the maxillary edentulous stratum ranged from 94.6% for the bar-retained overdenture supported by five to six fixtures to 81.8% for the cap-retained overdenture. The mandibular edentulous strata produced success rates of 98.1% for the fixed hybrid prosthesis to 91.7% for the cap-retained prosthesis. Success rates for maxillary and mandibular posterior fixed partial dentures were 94.3% and 92.6%, respectively, while the maxillary anterior single-tooth prosthesis yielded a success rate of 98.1% for the 36-month observation period. The recommended prosthesis designs investigated in this study proved to be reliable, with encouraging success rates for an observation period of 36 months following placement.

  13. Rresence of different Candida species at denture wearers with type 2 diabetes and clinically healthy oral mucosa: Pilot study

    OpenAIRE

    Matić-Petrović, Sanja; Barać, Milena; Kuzmanović-Pfićer, Jovana; Radunović, Milena; Jotić, Aleksandra; Pucar, Ana

    2018-01-01

    Background/Aim: The aim of this study was to examine prevalence of different Candida spp. at diabetics and nondiabetics wearing dentures without clinical signs of Denture Stomatitis (DS) and to study if some local and systematic factors are confounders for harboring Candida at these subjects. Material and Methods: Total of 60 subjects wearing partial or complete upper acrylic denture having at least half of palatal mucosa covered by denture were selected and stratified into three experimental...

  14. The nose shape as a predictor of maxillary central and lateral incisor width.

    Science.gov (United States)

    Sülün, Tonguç; Ergin, Ugur; Tuncer, Necat

    2005-09-01

    One of the primary aspects of complete denture prosthodontics is determining the correct proportion for the maxillary central incisor width to the lateral incisor width. It has been suggested that the anatomy of the patient's nose is a reliable guide for deciding this ratio. The aim of this study was to test the hypothesis about the relationship between the shape of the nose and the proportion of the central incisor width (CIW) to the lateral incisor width (LIW). The CIW and LIW from a total of 138 subjects (73 males, 65 females) were measured intraorally. The interalar width (IAW) and the width of the root of the nose (WRN) were measured on standard photographs of the subjects. Spearman's rho test was used to analyze the correlation between the proportions of the CIW to the LIW and the IAW to the WRN. The Mann-Whitney Utest was applied to test for any possible gender differences. The IAW, the WRN, and the nose angle (NA) were statistically significantly wider in male subjects than in female subjects. The correlation between IAW/WRN, NA, and CIW/LIW was statistically significant only in female subjects. In the general population, the only statistically significant relationship was between CIW/LIW on the left side and IAW/WRN. Within the results of the IAW, WRN, and NA measurements, we suggest that males have wider, more triangular-shaped noses than females. The proportion of IAW to WRN seems to be a reliable guide for deciding the proportion of the maxillary central incisor width to the lateral incisor.

  15. Denture adhesives: a systematic review.

    Science.gov (United States)

    Papadiochou, Sofia; Emmanouil, Ioannis; Papadiochos, Ioannis

    2015-05-01

    Denture adhesives have been the objective of scientific research for over half a century. Although they are used by denture wearers worldwide, investigations of their effectiveness and biocompatibility have led to controversial conclusions. The purpose of this study was to review the literature data with regard to the effectiveness and biocompatibility of denture adhesives as well as the attitudes of both patients and dental professionals toward these materials. An electronic search of English peer-reviewed dental literature in the Medline database was conducted to evaluate the effectiveness and biocompatibility of denture adhesives. There was no limitation in publication year, so the search included all the available scientific evidence included in that particular database until March 2014. Specific inclusion criteria were used for the selection of the appropriate articles. A manual search of the citations of the obtained articles followed to extend the electronic search. A full text review was carried out for only 32 articles. Of the 32 articles, 21 examined the efficacy of denture adhesives in terms of retention and stability and masticatory performance, 6 evaluated the issue of the biocompatibility of denture adhesives, and 5 presented the attitudes of either professionals or patients toward these materials. The majority of clinical studies supported the fact that denture adhesives enhance the retention, stability, and masticatory performance of a removable prosthesis. In terms of biocompatibility, long-term in vivo studies to investigate potential harmful effects were lacking. Patients are satisfied with denture adhesives that meet their needs. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Assessment of the prevalence index on signs of combination syndrome in patients treated at Bauru School of Dentistry, University of Sao Paulo

    Directory of Open Access Journals (Sweden)

    Milton Carlos Gonçalves Salvador

    2007-02-01

    Full Text Available A group of destructive changes occurring in jaws in patients with maxillary complete dentures and mandibular removable partial dentures (bilaterally has been described in the literature as the combination syndrome. However, this condition is not clinically observed in all patients. The aim of this study was to establish the prevalence index on signs of combination syndrome and to verify whether these changes also occurred in patients rehabilitated with a mandibular removable partial denture (unilaterally. Sample was composed of 44 patients, completely edentulous in the maxilla. Thirty-two patients had a Kennedy Class I removable partial denture and 12 a Kennedy Class II. Three major alterations were observed in 20.5% of the studied population. Nevertheless, these changes were present only in 25% of patients with Kennedy Class I removable partial denture. Based on the findings of this study, it can be concluded that patients with Kennedy Class II removable partial denture do not have similar signs that lead to the combination syndrome's condition.

  17. Effect of implant support on mandibular distal extension removable partial dentures: relationship between denture supporting area and stress distribution.

    Science.gov (United States)

    Sato, Maki; Suzuki, Yasunori; Kurihara, Daisuke; Shimpo, Hidemasa; Ohkubo, Chikahiro

    2013-04-01

    This study explored the relationship between implant support and the denture-supporting area by comparing the stability of an implant-supported distal extension removable partial denture and a conventional distal extension removable partial denture. A model simulating a mandibular bilateral distal extension missing (#34-37 and #44-47) was fabricated using silicone impression material as soft tissue (2 mm thick) on an epoxy resin bone model. The denture base was reduced by 5 mm cutting part of both the retromolar pad and the lingual border. Loads of up to 5 kg were applied, and the pressure and displacement of the RPDs were simultaneously measured and analyzed using the Wilcoxon test (αremovable partial denture (ISRPD) was significantly less than on the conventional RPD (CRPD). As the supporting area of the denture base decreased, the pressure and the denture displacement of the CRPD were greater than for the ISRPD. This study indicated that implant placement at the distal edentulous ridge can prevent denture displacement of the distal extension bases, regardless of the supporting area of the denture base. Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  18. An economic evaluation of maxillary implant overdentures based on six vs. four implants.

    Science.gov (United States)

    Listl, Stefan; Fischer, Leonhard; Giannakopoulos, Nikolaos Nikitas

    2014-08-18

    The purpose of the present study was to assess the value for money achieved by bar-retained implant overdentures based on six implants compared with four implants as treatment alternatives for the edentulous maxilla. A Markov decision tree model was constructed and populated with parameter estimates for implant and denture failure as well as patient-centred health outcomes as available from recent literature. The decision scenario was modelled within a ten year time horizon and relied on cost reimbursement regulations of the German health care system. The cost-effectiveness threshold was identified above which the six-implant solution is preferable over the four-implant solution. Uncertainties regarding input parameters were incorporated via one-way and probabilistic sensitivity analysis based on Monte-Carlo simulation. Within a base case scenario of average treatment complexity, the cost-effectiveness threshold was identified to be 17,564 € per year of denture satisfaction gained above of which the alternative with six implants is preferable over treatment including four implants. Sensitivity analysis yielded that, depending on the specification of model input parameters such as patients' denture satisfaction, the respective cost-effectiveness threshold varies substantially. The results of the present study suggest that bar-retained maxillary overdentures based on six implants provide better patient satisfaction than bar-retained overdentures based on four implants but are considerably more expensive. Final judgements about value for money require more comprehensive clinical evidence including patient-centred health outcomes.

  19. Efficacy of Denture Cleansers in Reducing Microbial Counts from Removable Partial Dentures: A Short-Term Clinical Evaluation

    OpenAIRE

    Lucena-Ferreira,Silvia Carneiro de; Cavalcanti,Indira Moraes Gomes; Cury,Altair Antoninha Del Bel

    2013-01-01

    This clinical study investigated if daily immersion in denture cleansers reduces microbial counts on removable partial denture's (RPD) biofilm. Twenty-five RPD wearer volunteers were selected and instructed to complement the hygiene of their dentures by immersing them in an enzymatic peroxide-based denture cleanser (Polident® 3 minute) once a day for 3 min for a period of 15 days. The biofilm was collected from RPD surfaces with a swab immediately before (baseline) and after the experimental ...

  20. The influence of polishing techniques on pre-polymerized CAD\\CAM acrylic resin denture bases.

    Science.gov (United States)

    Alammari, Manal Rahma

    2017-10-01

    Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. The purpose of this study was to inspect the effects of mechanical polishing and chemical polishing on the surface roughness (Ra) and contact angle (wettability) of heat-cured, auto-cured and CAD/CAM denture base acrylic resins. This study was conducted at the Advanced Dental Research Laboratory Center of King Abdulaziz University from March to June 2017. Three denture base materials were selected: heat cure poly-methylmethacrylate resin, thermoplastic (polyamide resin) and (CAD\\CAM) denture base resin. Sixty specimens were prepared and divided into three groups, twenty in each. Each group was divided according to the polishing techniques into (Mech P) and (Chem P), ten specimens in each; surface roughness and wettability were investigated. Data were analyzed by SPSS version 22, using one-way ANOVA and Pearson coefficient. One-way analysis of variance (ANOVA) and post hoc tests were used for comparing the surface roughness values between three groups which revealed a statistical significant difference between them (p 1 CAD\\CAM denture base material (group III) showed the least mean values (1.08±0.23, 1.39±0.31, Mech P and Chem P respectively). CAD/CAM showed the least contact angle in both polishing methods, which were statistically significant at 5% level (p=0.034 and pCAD\\CAM denture base resin with superior smooth surface compared to chemical polishing. Mechanical polishing is considered the best effective polishing technique. CAD/CAM denture base material should be considered as the material of choice for complete denture construction in the near future, especially for older dental

  1. Aspergilloma of the maxillary sinus: report of a case

    International Nuclear Information System (INIS)

    Kang, Ju Han; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan; Yu, Jae Jung

    2010-01-01

    Aspergilloma of the paranasal sinus is a non-invasive form of aspergillosis, most often in the maxillary sinus. This case presents an 86-year-old female with aspergilloma of the left maxillary sinus. The patient's chief complaint was intermittent pain on the left maxillary first premolar area. A radiopacification of the left maxillary sinus was observed on the panoramic radiograph. Cone-beam computed tomography revealed complete radiopacification of the left maxillary sinus and scattered multiple radiopaque mass inside the lesion. Biopsy was performed under local anesthesia. On microscopic examination, numerous fungal hyphae, which branch at acute angle, were observed. The diagnosis was made as an aspergilloma based on the histopathologic examination.

  2. [Conventional retaining of removable partial dentures

    NARCIS (Netherlands)

    Keltjens, H.M.A.M.; Witter, D.J.; Creugers, N.H.J.

    2009-01-01

    Mechanical and biological criteria have to be met in retaining the metal frame of a removable partial denture. Additionally, a removable partial denture is part of the occlusal interface by the clasps and the denture teeth. With respect to mechanical aspects, all rigid parts of the removable partial

  3. Efficacy of commercial and household denture cleansers against Candida albicans adherent to acrylic denture base resin: An in vitro study

    Directory of Open Access Journals (Sweden)

    M Nanditha Kumar

    2012-01-01

    Conclusion: Within the limitations of this in vitro study, denture cleansers were found to be effective in reducing C albicans cells adhering to dentures. The commercial denture cleansers (Fittydent® and Clinsodent® were more effective than household denture cleansers (vinegar and diluted vinegar.

  4. A clinical study to evaluate the correlation between maxillary central incisor tooth form and face form in an Indian population.

    Science.gov (United States)

    Koralakunte, Pavankumar R; Budihal, Dhanyakumar H

    2012-09-01

    A study was performed to examine the correlation between maxillary central incisor tooth form and face form in males and females in an Indian population. The selection of prosthetic teeth for edentulous patients is a primary issue in denture esthetics, especially in the case of maxillary central incisors, which are the most prominent teeth in the arch. Two hundred dental students of Indian origin comprising 79 males and 121 females aged 18-28 years studying at Bapuji Dental College and Hospital were randomly selected as the study subjects. A standardized photographic procedure was used to obtain images of the face and the maxillary central incisors. The outline forms of the face and the maxillary right central incisor tooth were determined using a standardized method. The outline forms obtained were used to classify both face form and tooth form on the basis of visual and William's methods. The means were considered after evaluation by five prosthodontists, and the results were tabulated. Statistical analysis was performed using the chi-squared test for association and Z-test for equality of proportions. A correlation greater than 50% was observed between tooth form and face form by the visual method, compared with one of 31.5% by William's method. There was no highly defined correlation between maxillary central incisor tooth form and face form among the male and female Indian subjects studied.

  5. Usage of removable partial dentures in Saudi male patients after 1 year telephone interview

    Science.gov (United States)

    Akeel, Riyadh

    2010-01-01

    Objective The success of removable partial dentures (RPDs) is partly dependent on patients’ acceptance and compliance in using them. The purpose of this study was to describe the usage of removable partial dentures (RPDs) by patients 1 year after insertion and to evaluate the factors that influence their denture usage. Methods Forty-seven patients who received 75 new RPDs at the undergraduate clinic of College of Dentistry, King Saud University, were contacted by telephone 1 year later for an interview. The questions covered denture usage, patient’s satisfaction and reasons for non-use. Results Results showed that 36% of patients discarded or occasionally used their RPDs. There was no significant association between denture usage and RPD experience, location or Kennedy classification. A significantly more RPD rejection was found when it was opposed by natural teeth or complete denture. The most quoted reason for RPD rejection was pain and discomfort. Conclusion Despite the short follow-up period, RPDs were poorly accepted by patients treated by undergraduate students. PMID:23960487

  6. The Oral Microbiome of Denture Wearers Is Influenced by Levels of Natural Dentition

    Science.gov (United States)

    O’Donnell, Lindsay E.; Robertson, Douglas; Nile, Christopher J.; Cross, Laura J.; Riggio, Marcello; Sherriff, Andrea; Bradshaw, David; Lambert, Margaret; Malcolm, Jennifer; Buijs, Mark J.; Zaura, Egija; Crielaard, Wim; Brandt, Bernd W.; Ramage, Gordon

    2015-01-01

    Objectives The composition of dental plaque has been well defined, whereas currently there is limited understanding of the composition of denture plaque and how it directly influences denture related stomatitis (DS). The aims of this study were to compare the microbiomes of denture wearers, and to understand the implications of these towards inter-kingdom and host-pathogen interactions within the oral cavity. Methods Swab samples were obtained from 123 participants wearing either a complete or partial denture; the bacterial composition of each sample was determined using bar-coded illumina MiSeq sequencing of the bacterial hypervariable V4 region of 16S rDNA. Sequencing data processing was undertaken using QIIME, clustered in Operational Taxonomic Units (OTUs) and assigned to taxonomy. The dentures were sonicated to remove the microbial flora residing on the prosthesis, sonicate was then cultured using diagnostic colorex Candida media. Samples of unstimulated saliva were obtained and antimicrobial peptides (AMP) levels were measured by ELISA. Results We have shown that dental and denture plaques are significantly distinct both in composition and diversity and that the oral microbiome composition of a denture wearer is variable and is influenced by the location within the mouth. Dentures and mucosa were predominantly made up of Bacilli and Actinobacteria. Moreover, the presence of natural teeth has a significant impact on the overall microbial composition, when compared to the fully edentulous. Furthermore, increasing levels of Candida spp. positively correlate with Lactobacillus spp. AMPs were quantified, though showed no specific correlations. Conclusions This is the first study to provide a detailed understanding of the oral microbiome of denture wearers and has provided evidence that DS development is more complex than simply a candidal infection. Both fungal and bacterial kingdoms clearly play a role in defining the progression of DS, though we were unable to

  7. Aspergilloma of the maxillary sinus: report of a case

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ju Han; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan [School of Dentistry, Kung Hee University, Seoul (Korea, Republic of); Yu, Jae Jung [Kangdong Scared Heart Hospital, Hallym Medical Center, Seoul (Korea, Republic of)

    2010-12-15

    Aspergilloma of the paranasal sinus is a non-invasive form of aspergillosis, most often in the maxillary sinus. This case presents an 86-year-old female with aspergilloma of the left maxillary sinus. The patient's chief complaint was intermittent pain on the left maxillary first premolar area. A radiopacification of the left maxillary sinus was observed on the panoramic radiograph. Cone-beam computed tomography revealed complete radiopacification of the left maxillary sinus and scattered multiple radiopaque mass inside the lesion. Biopsy was performed under local anesthesia. On microscopic examination, numerous fungal hyphae, which branch at acute angle, were observed. The diagnosis was made as an aspergilloma based on the histopathologic examination.

  8. Investigating Frequency of Temporo- Mandibular Dysfunctions in Complete Denture Wearers Referring to the Prosthesis Department of Dental School during 2013-2014

    Directory of Open Access Journals (Sweden)

    MH Lotfikamran

    2016-04-01

    Results: 46 patients (46% were male, 54 patients (54% were female, and the age range was 35-64 years. The range of using denture was 1-3 years and the mean duration of using denture was 2.52 ± 1.58 years. The most common age range for the relevant disorders was 40-50 years and the frequency of TMD was more in women than in men. Moreover, there was a significant relationship between age factor and Anamnestic index (P=0.037, whereas no significant relationship was observed between frequency of these disorders, level of education and also duration of using previous denture. Conclusion: The study findings revealed that it seems that with increasing age the rate of complaints from TMD problems increases.

  9. Mucous retention cyst of the soft palate: a case presentation.

    Science.gov (United States)

    Ellis, S G; Lee, N J; Peckitt, N S

    1995-12-01

    This article describes a mucous retention cyst of the soft palate associated with an over-extended complete maxillary denture. The clinical and anatomical relevance of the fovea palatinae are discussed with respect to the posterior palatal seal and post-dam positioning.

  10. Denture hygiene knowledge and practice amongst patients in a ...

    African Journals Online (AJOL)

    Aim: To assess patients' knowledge on denture hygiene and the hygiene methods used for cleaning removable partial dentures. Methods: This was a ... Other information obtained were the duration of denture use, frequency of denture cleaning and type of material used for denture cleaning. Results: The age of the ...

  11. [Removable partial dentures. Oral functions and types

    NARCIS (Netherlands)

    Creugers, N.H.J.; Baat, C. de

    2009-01-01

    A removable partial denture enables the restoration or improvement of 4 oral functions: aesthetics, mandibular stability, mastication, and speech. However, wearing a removable partial denture should not cause oral comfort to deteriorate. There are 3 types of removable partial dentures: acrylic

  12. Clinical application of removable partial dentures using thermoplastic resin-part I: definition and indication of non-metal clasp dentures.

    Science.gov (United States)

    Fueki, Kenji; Ohkubo, Chikahiro; Yatabe, Masaru; Arakawa, Ichiro; Arita, Masahiro; Ino, Satoshi; Kanamori, Toshikazu; Kawai, Yasuhiko; Kawara, Misao; Komiyama, Osamu; Suzuki, Tetsuya; Nagata, Kazuhiro; Hosoki, Maki; Masumi, Shin-Ichi; Yamauchi, Mutsuo; Aita, Hideki; Ono, Takahiro; Kondo, Hisatomo; Tamaki, Katsushi; Matsuka, Yoshizo; Tsukasaki, Hiroaki; Fujisawa, Masanori; Baba, Kazuyoshi; Koyano, Kiyoshi; Yatani, Hirofumi

    2014-01-01

    This position paper proposes a definition and naming standard for removable partial dentures (RPDs) using thermoplastic resin, and presents a guideline for clinical application. A panel of 14 experts having broad experience with clinical application of RPDs using thermoplastic resin was selected from members of the Japan Prosthodontic Society. At a meeting of the panel, "non-metal clasp denture" was referred as the generic name of RPDs with retentive elements (resin clasps) made of thermoplastic resin. The panel classified non-metal clasp dentures into two types: one with a flexible structure that lacks a metal framework and the other having a rigid structure that includes a metal framework. According to current prosthetic principles, flexible non-metal clasp dentures are not recommended as definitive dentures, except for limited cases such as patients with a metal allergy. Rigid non-metal clasp dentures are recommended in cases where patients will not accept metal clasps for esthetic reasons. Non-metal clasp dentures should follow the same design principles as conventional RPDs using metal clasps. Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. Digitally Milled Metal Framework for Fixed Complete Denture with Metal Occlusal Surfaces: A Design Concept.

    Science.gov (United States)

    AlBader, Bader; AlHelal, Abdulaziz; Proussaefs, Periklis; Garbacea, Antonela; Kattadiyil, Mathew T; Lozada, Jaime

    Implant-supported fixed complete dentures, often referred to as hybrid prostheses, have been associated with high implant survival rates but also with a high incidence of mechanical prosthetic complications. The most frequent of these complications have been fracture and wear of the veneering material. The proposed design concept incorporates the occlusal surfaces of the posterior teeth as part of a digital milled metal framework by designing the posterior first molars in full contour as part of the framework. The framework can be designed, scanned, and milled from a titanium blank using a milling machine. Acrylic resin teeth can then be placed on the framework by conventional protocol. The metal occlusal surfaces of the titanium-countered molars will be at centric occlusion. It is hypothesized that metal occlusal surfaces in the posterior region may reduce occlusal wear in these types of prostheses. When the proposed design protocol is followed, the connection between the metal frame and the cantilever part of the prosthesis is reinforced, which may lead to fewer fractures of the metal framework.

  14. Dental health professional recommendation and consumer habits in denture cleansing.

    Science.gov (United States)

    Axe, Alyson S; Varghese, Roshan; Bosma, MaryLynn; Kitson, Nicola; Bradshaw, David J

    2016-02-01

    Regular cleaning of dentures is essential to the oral and general health of denture wearers. Only limited systematic data are available on the recommendations that dental health care professionals (DHCPs) make to patients for denture cleaning. Data on denture wearers' cleaning regimens are also lacking. The purpose of this study was to provide data on recommendations that DHCPs make to patients for denture cleaning and on the cleaning regimens of denture wearers. DHCPs (n=613), including dentists and hygienists, were surveyed in developed (Japan, USA, Italy) and developing (Brazil, India) countries. A questionnaire assessing a range of denture cleaning recommendations was used. The questions addressed products, frequency, how to use remedies, the suggested dilution and duration of cleansing treatment, the location of dentures while cleaning, and the reasoning behind the recommendation of particular products or modes of treatment. Denture cleansing methods and the routine of denture wearers in developed and developing countries were also surveyed with a questionnaire (n=2862) and a 1-week diary (n=1462). An average of more than 2 treatments was recommended by DHCPs. Specialist denture cleanser tablets, "regular" toothpaste, mouthwash, soap and water, denture paste, foam or liquid denture cleanser, and dishwashing detergents were most commonly recommended; other product recommendations included baking soda, vinegar, salt water, and bleach. More than 10% of DHCPs made no primary recommendation on cleaning. Denture tablets were more commonly recommended in developed countries, whereas toothpaste was the most common recommendation in developing countries. Denture wearers used products and methods similar to those recommended by DHCPs. Toothpaste, water, and mouthwash were used more frequently than denture tablets. More than 75% of denture wearers reported using denture cleanser tablets for more than 5 minutes, whereas soap and toothpaste were typically used for less

  15. Telescopic Overdenture: A Case Report

    OpenAIRE

    Shruthi, C. S.; Poojya, R.; Ram, Swati; Anupama,

    2017-01-01

    Patient: This report describes the case of a 68 year old female patient who presented with the chief complaint of difficulty in chewing and poor aesthetics due to missing teeth. The patient was interested in saving the remaining natural teeth and desired minimal tissue coverage from the prosthesis. After consideration of all the factors involved, it was deemed advisable to resort to a palate free maxillary telescopic complete denture and a mandibular removable partial denture. Discussion: Con...

  16. [Effects of maxillary distraction osteogenesis on the velopharyngeal configuration of cleft palate patients].

    Science.gov (United States)

    Wang, Xiao-xia; Wang, Xing; Yi, Biao; Li, Zi-li; Liang, Cheng

    2005-12-18

    To study the effects of internal maxillary distraction osteogenesis(DO) on the velopharyngeal configuration of cleft palate patients. Ten patients with severe maxillary hypoplasia secondary to cleft lip and palate patients (7 males and 3 females, average age 20.1 years old) had undertaken high step LeFort I osteotomy, and internal maxillary distraction devices were applied to advance the maxilla. Before surgery, when DO was completed and 6 months after DO was completed, oriented lateral cephalograms at rest position of each patient were taken, and 6 measure indexes of velopharyngeal configuration were collected and analyzed. All patients had successfully accomplished maxillary DO and the maxilla had been averagely advanced 11.3 mm. PNS-PhW, C-PhW, UL and ANS-PNS-T had all significantly increased, and UD had significantly decreased when DO was completed and 6 months after DO was completed as compared with pre-surgery. No significant linear correlation was found between maxilla advancement distance and velopharyngeal configuration changes. Correction of maxillary hypoplasia secondary to cleft palate surgery by using internal maxillary DO can increase the velopharyngeal cavity depth, and may impair velopharyngeal competence, but the compensatory changes of velopharyngeal soft tissue can alleviate this impairment to certain extent.

  17. Complication rates and patient satisfaction with removable dentures

    Science.gov (United States)

    Bilhan, Hakan; Erdogan, Ozge; Ergin, Selen; Celik, Melahat; Ates, Gokcen

    2012-01-01

    PURPOSE The purpose of this clinical study was to evaluate the frequency and type of prosthetic complications in relation to type and properties of removable dentures and to investigate the influence of these complications and several data about the existing dentures on patient satisfaction. MATERIALS AND METHODS Ninety nine patients (44 males and 55 females) wearing removable dentures have been included in the study. The complications of the patients were recorded; patient satisfaction was determined with a Visual Analog Scale (VAS) and the relationship of complications and patient satisfaction with several data about the dentures such as denture age, type of denture, centric relation and vertical dimension was investigated. Kruskal Wallis, Mann Whitney U and Chi square tests were used for statistical analyses. The results were evaluated statistically at a significance level of Pdentures with correct centric relations was found to be significantly lower than dentures with wrong centric relations (Pdentures with wrong centric relations caused need for addition of artificial teeth. PMID:22737317

  18. A follow-up study on removable partial dentures in undergraduate program: part I. participants and denture use by telephone survey.

    Science.gov (United States)

    Yoshida, Eiko; Fueki, Kenji; Igarashi, Yoshimasa

    2011-07-04

    The aim of this study was to investigate the clinical outcome of removable partial dentures (RPDs) designed to minimize denture mobility during function. Using archived files of the undergraduate program between 2003 and 2005 at Tokyo Medical and Dental University, a list of 169 patients treated with 184 RPDs was created. The RPDs had either an acrylic resin-base or a cobalt-chrome framework-base. Two examiners telephoned all the listed patients and interviewed 118 patients (70%) regarding the use of their RPDs. Of 118 patients, 42 (36%) had stopped using, mainly due to problems with abutment teeth in resin-based dentures, and replacement in cobalt-chrome-based dentures. There was no significant difference in mean age, gender distribution, mean number of remaining/abutment teeth, distribution of denture arch, and Kennedy classification between denture use and nonuse groups (p>0.05). The nonuse group showed a significantly higher percentage of resin-base compared to the use group (p = 0.006). Logistic regression analysis indicated that resin-base was a significant risk factor for nonuse (p = 0.008). The present findings suggest that abutment teeth should be selected carefully, especially in this type of resin-based RPDs, and that the denture base material may be a critical factor which determines denture use.

  19. Denture-related oral mucosal lesions among removable denture wearers ‎referred to clinics of Kerman, Iran

    Directory of Open Access Journals (Sweden)

    Shahrzad Taheri

    2016-05-01

    CONCLUSION: The finding of this study showed the prevalence of denture-related mucosal lesions is common. Dentists should be instruct the patients for removing the denture at night and routine follow-up visits.

  20. Pressure distribution of implant-supported removable partial dentures with stress-breaking attachments.

    Science.gov (United States)

    Kono, Kentaro; Kurihara, Daisuke; Suzuki, Yasunori; Ohkubo, Chikahiro

    2014-04-01

    This in vitro study investigated the pressure distribution of the implant-supported removable partial dentures (RPDs) with the stress-breaking attachments under the occlusal force. The experimental model of bilateral missing premolars and molars was modified from a commercial simulation model. Five pressure sensors were embedded near the bilateral first molars, first premolars, and medio-lingual alveolar crest. Two implants were placed near the second molars, and they were connected to the denture base using the following conditions: complete separation between the denture base and implant with cover screws (CRPD), flexible connection with a stress-breaking ball (SBB) attachment, and rigid connection without stress breaking with healing caps (HC). The pressure at five different areas of the soft tissue and the displacement of the RPDs were simultaneously measured, loading up to 50 N. The coefficient of variation (CV) for each connection was calculated from all data of the pressure at five areas to evaluate the pressure distribution. The pressure on medio-lingual alveolar crest and molars of the HC was less than SBB and CRPD. In contrast, the pressure on premolars of SBB was greater than for the HC and CRPD. The CV of SBB was less than that of HC and CRPD. Denture displacement of HC and SBB was less than for CRPD. Within the in vitro limitations, precise denture settlements and pressure distribution under the denture base could be controlled using an SBB attachment. An SBB attachment might be able to protect the implant from harmful force. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  1. A simple method for fabricating custom sectional impression trays for making definitive impressions in patients with microstomia

    OpenAIRE

    Bachhav, Vinay Chila; Aras, Meena Ajay

    2012-01-01

    Objective: A maximum mouth opening that is smaller than the size of a complete denture can make prosthetic treatment challenging. This article describes a simple technique used to fabricate maxillary and mandibular custom sectional impression trays for making definitive impressions in patients with microstomia.

  2. Comparative evaluation of the effect of denture cleansers on the surface topography of denture base materials: An in-vitro study.

    Science.gov (United States)

    Jeyapalan, Karthigeyan; Kumar, Jaya Krishna; Azhagarasan, N S

    2015-08-01

    The aim was to evaluate and compare the effects of three chemically different commercially available denture cleansing agents on the surface topography of two different denture base materials. Three chemically different denture cleansers (sodium perborate, 1% sodium hypochlorite, 0.2% chlorhexidine gluconate) were used on two denture base materials (acrylic resin and chrome cobalt alloy) and the changes were evaluated at 3 times intervals (56 h, 120 h, 240 h). Changes from baseline for surface roughness were recorded using a surface profilometer and standard error of the mean (SEM) both quantitatively and qualitatively, respectively. Qualitative surface analyses for all groups were done by SEM. The values obtained were analyzed statistically using one-way ANOVA and paired t-test. All three denture cleanser solutions showed no statistically significant surface changes on the acrylic resin portions at 56 h, 120 h, and 240 h of immersion. However, on the alloy portion changes were significant at the end of 120 h and 240 h. Of the three denture cleansers used in the study, none produced significant changes on the two denture base materials for the short duration of immersion, whereas changes were seen as the immersion periods were increased.

  3. In vitro comparison of the tensile bond strength of denture adhesives on denture bases.

    Science.gov (United States)

    Kore, Doris R; Kattadiyil, Mathew T; Hall, Dan B; Bahjri, Khaled

    2013-12-01

    With several denture adhesives available, it is important for dentists to make appropriate patient recommendations. The purpose of this study was to evaluate the tensile bond strength of denture adhesives on denture base materials at time intervals of up to 24 hours. Fixodent, Super Poligrip, Effergrip, and SeaBond denture adhesives were tested with 3 denture base materials: 2 heat-polymerized (Lucitone 199 and SR Ivocap) and 1 visible-light-polymerized (shade-stable Eclipse). Artificial saliva with mucin was used as a control. Tensile bond strength was tested in accordance with American Dental Association specifications at 5 minutes, 3 hours, 6 hours, 12 hours, and 24 hours after applying the adhesive. Maximum forces before failure were recorded in megapascals (MPa), and the data were subjected to a 2-way analysis of variance (α=.05). All 4 adhesives had greater tensile bond strength than the control. Fixodent, Super Poligrip, and SeaBond had higher tensile bond strength values than Effergrip. All adhesives had the greatest tensile bond strength at 5 minutes and the least at 24 hours. The 3 denture bases produced significantly different results with each adhesive (Padhesives had the greatest tensile bond strength, followed by Ivocap and Eclipse. All 4 adhesives had greater tensile bond strength than the control, and all 4 adhesives were strongest at the 5-minute interval. On all 3 types of denture bases, Effergrip produced significantly lower tensile bond strength, and Fixodent, Super Poligrip, and SeaBond produced significantly higher tensile bond strength. At 24 hours, the adhesive-base combinations with the highest tensile bond strength were Fixodent on Lucitone 199, Fixodent on Eclipse, Fixodent on Ivocap, and Super Poligrip on Ivocap. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  4. Liquid supported denture-management of flabby ridges

    Directory of Open Access Journals (Sweden)

    Pranav V Mody

    2012-01-01

    Full Text Available The ideal properties of a denture are adequate rigidity on polished surface to bear masticatory forces and at the same time, flexibility and softness on the tissue surface for proper and even distribution of masticatory forces. The problem with conventional denture is rigidity of tissue surface; leads to uneven distribution of load. This drawback even worsens in the case of flabby, atrophic and unemployed ridges with excessive bone resorption.The liquid supported denture allows continued adaptation and eliminates the disadvantages of denture designs based on the application of temporary tissue conditioners or soft liners.

  5. Bilateral iatrogenic maxillary fractures after dental treatment in two aged horses

    OpenAIRE

    Widmer, A; Fürst, A; Bettschart-Wolfensberger, R; Makara, M; Geyer, H; Kummer, M

    2010-01-01

    This clinical report describes two horses with bilateral maxillary fractures following dental treatment. The fractures occurred during dental treatment by a veterinarian, and both had rostral, transverse, and complete bilateral maxillary fractures with instability and minimal displacement. The fractures were repaired using bilateral intraoral wiring with the patients under general anesthesia. The postoperative period was without complications and the fractures healed as expected. Maxillary fr...

  6. [Acrylic resin removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de; Witter, D.J.; Creugers, N.H.J.

    2011-01-01

    An acrylic resin removable partial denture is distinguished from other types of removable partial dentures by an all-acrylic resin base which is, in principle, solely supported by the edentulous regions of the tooth arch and in the maxilla also by the hard palate. When compared to the other types of

  7. Present status of titanium removable dentures--a review of the literature.

    Science.gov (United States)

    Ohkubo, C; Hanatani, S; Hosoi, T

    2008-09-01

    Although porcelain and zirconium oxide might be used for fixed partial dental prostheses instead of conventional dental metals in the near future, removable partial denture (RPD) frameworks will probably continue to be cast with biocompatible metals. Commercially pure (CP) titanium has appropriate mechanical properties, it is lightweight (low density) compared with conventional dental alloys, and has outstanding biocompatibility that prevents metal allergic reactions. This literature review describes the laboratory conditions needed for fabricating titanium frameworks and the present status of titanium removable prostheses. The use of titanium for the production of cast RPD frameworks has gradually increased. There are no reports about metallic allergy apparently caused by CP titanium dentures. The laboratory drawbacks still remain, such as the lengthy burn-out, inferior castability and machinability, reaction layer formed on the cast surface, difficulty of polishing, and high initial costs. However, the clinical problems, such as discoloration of the titanium surfaces, unpleasant metal taste, decrease of clasp retention, tendency for plaque to adhere to the surface, detachment of the denture base resin, and severe wear of titanium teeth, have gradually been resolved. Titanium RPD frameworks have never been reported to fail catastrophically. Thus, titanium is recommended as protection against metal allergy, particularly for large-sized prostheses such as RPDs or complete dentures.

  8. Long-term follow-up of early cleft maxillary distraction.

    Science.gov (United States)

    Park, Young-Wook; Kwon, Kwang-Jun; Kim, Min-Keun

    2016-12-01

    Most of cleft lip and palate patients have the esthetic and functional problems of midfacial deficiencies due to innate developmental tendency and scar tissues from repeated operations. In these cases, maxillary protraction is required for the harmonious facial esthetics and functional occlusion. A 7-year old boy had been diagnosed as severe maxillary constriction due to unilateral complete cleft lip and palate. The author tried to correct the secondary deformity by early distraction osteogenesis with the aim of avoiding marked psychological impact from peers of elementary school. From 1999 to 2006, repeated treatments, which consisted of Le Fort I osteotomy and face mask distraction, and complementary maxillary protraction using miniplates were performed including orthodontics. But, final facial profile was not satisfactory, which needs compromising surgery. The result of this study suggests that if early distraction treatment is performed before facial skeletal growth is completed, an orthognathic surgery or additional distraction may be needed later. Maxillofacial plastic and reconstructive surgeons should notify this point when they plan early distraction treatment for cleft maxillary deformity.

  9. Stress analysis on the free-end distal extension of an implant-supported mandibular complete denture

    Directory of Open Access Journals (Sweden)

    Gustavo Diniz Greco

    2009-06-01

    Full Text Available A comparative and qualitative analysis of the tensions generated in the cantilever region of an implant-supported mandibular complete denture was conducted using the three-dimensional finite element method. The mechanical properties of the components were input in the model and a load of 15 N was applied in pre-determined points. In the first simulation, the load was applied on the occlusal surface of the first premolar. In the second simulation, it was applied on the first and second premolars. In the third simulation, it was applied on the first and second premolars and on the first molar. The different occlusion patterns produced similar tension distributions in the cantilever region, which followed a similar pattern in the three simulations. In all of the cases, the highest levels of tension were located in the region of the first implant. However, as the loads were dislocated distally, the tensions increased considerably. The more extensive the cantilever, the more compromised will be the infrastructure, the prosthetic components and the implants. Regardless of the length of the cantilever, the highest tensions will always be located in the region of the implant next to the load application point.

  10. Generation and evaluation of 3D digital casts of maxillary defects based on multisource data registration: A pilot clinical study.

    Science.gov (United States)

    Ye, Hongqiang; Ma, Qijun; Hou, Yuezhong; Li, Man; Zhou, Yongsheng

    2017-12-01

    Digital techniques are not clinically applied for 1-piece maxillary prostheses containing an obturator and removable partial denture retained by the remaining teeth because of the difficulty in obtaining sufficiently accurate 3-dimensional (3D) images. The purpose of this pilot clinical study was to generate 3D digital casts of maxillary defects, including the defective region and the maxillary dentition, based on multisource data registration and to evaluate their effectiveness. Twelve participants with maxillary defects were selected. The maxillofacial region was scanned with spiral computer tomography (CT), and the maxillary arch and palate were scanned using an intraoral optical scanner. The 3D images from the CT and intraoral scanner were registered and merged to form a 3D digital cast of the maxillary defect containing the anatomic structures needed for the maxillary prosthesis. This included the defect cavity, maxillary dentition, and palate. Traditional silicone impressions were also made, and stone casts were poured. The accuracy of the digital cast in comparison with that of the stone cast was evaluated by measuring the distance between 4 anatomic landmarks. Differences and consistencies were assessed using paired Student t tests and the intraclass correlation coefficient (ICC). In 3 participants, physical resin casts were produced by rapid prototyping from digital casts. Based on the resin casts, maxillary prostheses were fabricated by using conventional methods and then evaluated in the participants to assess the clinical applicability of the digital casts. Digital casts of the maxillary defects were generated and contained all the anatomic details needed for the maxillary prosthesis. Comparing the digital and stone casts, a paired Student t test indicated that differences in the linear distances between landmarks were not statistically significant (P>.05). High ICC values (0.977 to 0.998) for the interlandmark distances further indicated the high

  11. 21 CFR 872.3580 - Preformed gold denture tooth.

    Science.gov (United States)

    2010-04-01

    ... tooth in a fixed or removable partial denture. (b) Classification. Class I (general controls). The... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Preformed gold denture tooth. 872.3580 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3580 Preformed gold denture tooth. (a...

  12. Controlling fungal biofilms with functional drug delivery denture biomaterials.

    Science.gov (United States)

    Wen, Jianchuan; Jiang, Fuguang; Yeh, Chih-Ko; Sun, Yuyu

    2016-04-01

    Candida-associated denture stomatitis (CADS), caused by colonization and biofilm-formation of Candida species on denture surfaces, is a significant clinical concern. We show here that modification of conventional denture materials with functional groups can significantly increase drug binding capacity and control drug release rate of the resulting denture materials for potentially managing CADS. In our approach, poly(methyl methacrylate) (PMMA)-based denture resins were surface grafted with three kinds of polymers, poly(1-vinyl-2-pyrrolidinone) (PNVP), poly(methacrylic acid) (PMAA), and poly(2-hydroxyethyl methacrylate) (PHEMA), through plasma-initiated grafting polymerization. With a grafting yield as low as 2 wt%, the three classes of new functionalized denture materials showed significantly higher drug binding capacities toward miconazole, a widely used antifungal drug, than the original PMMA denture resin control, leading to sustained drug release and potent biofilm-controlling effects against Candida. Among the three classes of functionalized denture materials, PNVP-grafted resin provided the highest miconazole binding capability and the most powerful antifungal and biofilm-controlling activities. Drug binding mechanisms were studied. These results demonstrated the importance of specific interactions between drug molecules and functional groups on biomaterials, shedding lights on future design of CADS-managing denture materials and other related devices for controlled drug delivery. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Candida albicans importance to denture wearers. A literature review.

    Science.gov (United States)

    Gleiznys, Alvydas; Zdanavičienė, Eglė; Žilinskas, Juozas

    2015-01-01

    Opportunistic oral fungal infections have spred, especially in denture wearers. Denture stomatitis is a common inflammatory reaction, multifactorial etiology, which is usually associated with Candida species, particularly Candida albicans, due to its high virulence, ability to adhere and form biofilms on oral cavity tissues and denture surfaces. This article highlights the pathogenesis, clinical presentation, and management strategies of Candida-associated denture stomatitis commonly encountered in dental practice.

  14. An extensive denture‑induced hyperplasia of maxilla | Veena ...

    African Journals Online (AJOL)

    Elimination of the inflammation and excision of the lesion is the treatment of choice. Denture induced hyperplasia in right maxillary buccal vestibule in a middle age old female patient was presented. Surgical excision was done and new denture was fabricated. Keywords: Denture hyperplasia, Denture, Epulis fissuratum ...

  15. Orthodontic management of bilateral maxillary canine-first premolar transposition and bilateral agenesis of maxillary lateral incisors: a case report.

    Science.gov (United States)

    Di Palma, Elena; Di Giuseppe, Biagio; Tepedino, Michele; Chimenti, Claudio

    2015-01-01

    Maxillary canine-first premolar transposition (Mx.C.P1) is an uncommon dental positional anomaly that may create many orthodontic problems from both esthetic and functional points of view. In this report we show the orthodontic management of a case of Mx.C.P1 associated with bilateral maxillary lateral incisor agenesis and unilateral mandibular second premolar agenesis The patient was treated with a multibracket appliance and the extraction of the lower premolar. treatment was completed without the need for any prosthetic replacement.

  16. Comparison of the Effect of two Denture Cleansers on Tensile bond Strength of a Denture Liner.

    Science.gov (United States)

    Farzin, M; Bahrani, F; Adelpour, E

    2013-09-01

    One of the most clinical challenging issues in prosthodontics is debonding of soft liners from the denture base. The aim of this study was to evaluate and compare tensile bond strength between soft liner and heat-cured acrylic resin when immersed in two different types of denture cleanser and distilled water, at different period of times. In this experimental in vivo study, 238 heat-cured acrylic blocks were made. A soft liner was embedded between the acrylic blocks. Samples were divided into four groups: 17 samples were in the control group and were not soaked in any solution .The remaining samples were divided into 3 groups (Distilled water, Calgon and Fittydent). Each group was then subdivided into two subcategories, regarding the immersion time variable; 15 and 45 minutes. All samples were placed in tension force and tensile bond strength was recorded with the testing machine. One- way ANOVA and Tucky HSD post-hoc test were adopted to analyze the yielded data (α> 0.05). Specimens which were immersed in two denture cleansers (Fittydent and Calgon) and in distilled water showed significant difference (p= 0.001) in bonding strength when compared to the control group. The subjects immersed in denture cleanser solutions and distilled water did not reveal any significant difference (p= 0.90). For all groups; most of the bonding failures (72%) were cohesive type. The effect of the denture cleansers and distilled water on the bond strength was not statistically different; however, the difference was significant between the immersed groups with the non-immersed group. Moreover, type of the denture cleanser did not show any effect on the tensile strength. The tensile strength increases with time of immersion.

  17. Telescopic Overdenture: A Case Report

    Science.gov (United States)

    Shruthi, C. S.; Poojya, R.; Ram, Swati; Anupama

    2017-01-01

    Patient: This report describes the case of a 68 year old female patient who presented with the chief complaint of difficulty in chewing and poor aesthetics due to missing teeth. The patient was interested in saving the remaining natural teeth and desired minimal tissue coverage from the prosthesis. After consideration of all the factors involved, it was deemed advisable to resort to a palate free maxillary telescopic complete denture and a mandibular removable partial denture. Discussion: Considering the age of the patient and the cost involved, implant supported prosthesis was ruled out as a treatment option for the patient. A telescopic denture was chosen as a favourable treatment option since it overcomes many of the problems posed by conventional complete dentures like progressive bone loss, lower stability and retention, loss of periodontal proprioception and low masticatory efficiency. It also provides minimal tissue coverage and better distribution of forces. Evaluation of occlusion, esthetics, phonetics and comfort after 24 hours, 1 week and 1 month of treatment showed that the patient was happy with the prosthesis and was able to speak and chew well. Conclusion: Telescopic overdentures have better retention and stability as compared to conventional complete dentures. They improve the chewing efficiency, patient comfort and also decrease the alveolar bone resorption. As such they are an excellent alternative to conventional complete denture treatment. PMID:28533736

  18. Telescopic Overdenture: A Case Report.

    Science.gov (United States)

    Shruthi, C S; Poojya, R; Ram, Swati; Anupama

    2017-03-01

    This report describes the case of a 68 year old female patient who presented with the chief complaint of difficulty in chewing and poor aesthetics due to missing teeth. The patient was interested in saving the remaining natural teeth and desired minimal tissue coverage from the prosthesis. After consideration of all the factors involved, it was deemed advisable to resort to a palate free maxillary telescopic complete denture and a mandibular removable partial denture. Considering the age of the patient and the cost involved, implant supported prosthesis was ruled out as a treatment option for the patient. A telescopic denture was chosen as a favourable treatment option since it overcomes many of the problems posed by conventional complete dentures like progressive bone loss, lower stability and retention, loss of periodontal proprioception and low masticatory efficiency. It also provides minimal tissue coverage and better distribution of forces. Evaluation of occlusion, esthetics, phonetics and comfort after 24 hours, 1 week and 1 month of treatment showed that the patient was happy with the prosthesis and was able to speak and chew well. Telescopic overdentures have better retention and stability as compared to conventional complete dentures. They improve the chewing efficiency, patient comfort and also decrease the alveolar bone resorption. As such they are an excellent alternative to conventional complete denture treatment.

  19. [Designing metal frame removable partial dentures

    NARCIS (Netherlands)

    Witter, D.J.; Barel, J.C.; Keltjens, H.M.A.M.; Creugers, N.H.J.

    2011-01-01

    Oral health care providers have the full responsibility for designing metal frame removable partial dentures and making all of the necessary preparations. Important principles of design are that the denture should hamper natural cleaning and daily oral hygiene as little as possible and that it

  20. EFFECT OF POLYMER PROSTHETIC CONSTRUCTION TREATED WITH GLOW-DISCHARGE PLASMA ON ORAL MUCOSA (CLINICAL CASE

    Directory of Open Access Journals (Sweden)

    E. O. Kudasova

    2017-01-01

    Full Text Available Prosthetic material should induce minimal pathological reaction when in contact with the oral mucosa, especially during oral rehabilitation of patients with tumors of the oral mucosa. The article presents monitoring of a patient after surgery for cancer of the buccal mucosa at the stage of orthopedic rehabilitation. Treatment plan proposed complex oral rehabilitation. A maxillary complete removable denture was manufactured as well as metalloceramic and partial mandibular dentures. Plasma chemical modification of the removable dentures was planned after correction of the prosthetics and primary adaptation. Removable dentures were applied at the maxilla and mandibula. Per our recommendations, the patient was examined weekly for a month and monthly for 6 months. No new tumors or pathological elements were observed.Conclusions. Changes in critical surface tension of the removable dentures made of acrylic plastic improve their biological characteristics as demonstrated by positive clinical dynamics. Prosthetic constructions with hydrophilic surface are recommended in complex clinical cases when patients with tumors of the oral mucosa require dentures.

  1. Effect of resilient liner on masticatory efficiency and general patient satisfaction in completely edentulous patients

    DEFF Research Database (Denmark)

    Mangtani, Nidhi; Pillai, Rajath; Babu, Dinesh

    2015-01-01

    Objectives: To assess the effect of resilient lined denture on patient masticatory efficiency, general patient satisfaction and denture quality as compare to conventional complete denture over a period of one year. Material and methodology: A total of 28 completely edentulous patients (14 males...... denture liner – group 2). All patients were clinically evaluated to assess the denture quality, and administered questionnaires for masticatory efficiency and patients general satisfaction level at three intervals i.e. one month (T0), 6 months (T1) and 1 year post-insertion (T2). Results: Statistical...... masticatory efficiency improved significantly over time in controls, while in experimental group masticatory efficiency remained the same (p>.05) for almost all the questions. Patient general satisfaction score at different time intervals for each question showed no significant difference (P>.05) on inter...

  2. Denture hyperplasia with areas simulating oral inverted ductal papilloma.

    Science.gov (United States)

    Vargas, Pablo Agustin; Perez, Danyel Elias da Cruz; Jorge, Jacks; Rangel, Ana Lúcia Carrinho Ayrosa; León, Jorge Esquiche; Almeida, Oslei Paes de

    2005-07-01

    Denture hyperplasia is a reactive lesion of the oral mucosa, usually associated to an ill-fitting denture. This lesion is easily diagnosed and in some cases distinct microscopic variations such as osseous, oncocytic and squamous metaplasia may be found. These metaplastic alterations probably are associated with the lymphocytic infiltrate usually present in denture hyperplasia. We present a case of denture hyperplasia containing salivary gland tissue with ductal alterations mimicking an oral inverted ductal papilloma.

  3. Clinical evaluation of the essential oil of "Satureja Hortensis" for the treatment of denture stomatitis

    Directory of Open Access Journals (Sweden)

    Ali Mohammad Sabzghabaee

    2012-01-01

    Full Text Available Background: The prevalence of denture stomatitis has been shown to vary from 15 to 65% in complete denture wearers. Satureja hortensis L. has been considered to have antinociceptive, anti-inflammatory, antifungal and antimicrobial activities in vitro and exhibits strong inhibitory effect on the growth of periodontal bacteria. The aim of this study was to evaluate the efficacy of a 1% gel formulation of S. hortensis essential oil for the treatment of denture stomatitis. Materials and Methods: A randomized, controlled clinical trial study was conducted on 80 patients (mean age 62.91±7.34 in two parallel groups treated either with S. hortensis essential oil 1% gel or placebo applied two times daily for two weeks. Denture stomatitis was diagnosed by clinical examination and paraclinical confirmation with sampling the palatal mucosa for Candida albicans. Data were analyzed using Chi-squared or Student′s t tests. Results: The erythematous lesions of palatal area were significantly reduced (P<0.0001 in the treatment group who applied 1% topical gel of S. hortensis essential oil and Candida colonies count were reduced significantly (P=0.001. Conclusion: Topical application of the essential oil of S. hortensis could be considered as an effective agent for the treatment of denture stomatitis.

  4. A clinical study to compare between resting and stimulated whole salivary flow rate and pH before and after complete denture placement in different age groups

    Directory of Open Access Journals (Sweden)

    B C Muddugangadhar

    2015-01-01

    Conclusion: Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. Clinical Implications: The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics.

  5. Treatment Outcomes Based on Patients' Self-Reported Measures after Receiving New Clasp or Precision Attachment-Retained Removable Partial Dentures.

    Science.gov (United States)

    Peršić, Sanja; Kranjčić, Josip; Pavičić, Daniela Kovačević; Mikić, Vlatka Lajnert; Čelebić, Asja

    2017-02-01

    To evaluate effects of a treatment taking into consideration esthetics, chewing, and oral health-related quality of life (OHRQoL) of two tooth replacement strategies for maxillary partially edentulous patients with clasp (C-RPD) and precision attachment (PA-RPD) retained removable partial dentures (RPD). The study included 150 patients (72 men, 78 women) who received maxillary RPDs; 88 patients received clasp and 62 patients received precision attachment retained RPDs. Patients completed three questionnaires before treatment and again 3 months after treatment: the Orofacial Esthetic Scale (OES), the Oral Health Impact Profile (OHIP-14), and the Chewing Function Questionnaire (CFQ). Statistical analysis comprised descriptive statistics, paired t-test, and two-factor ANOVA. Both RPD treatments yielded better after-treatment summary scores when compared with the baseline scores (p < 0.01); however, better results were obtained in the PA-RPD group. Gender, as a single factor, did not yield significant effects; mutual interaction of retention type and gender yielded significant effects. The PA-RPD female group assessed esthetics, chewing function, and OHRQoL significantly better than males, and significantly worse than males in the C-RPD group. The covariate baseline scores yielded statistically significant effects; patients with worse pretreatment condition benefited more from both therapies. Treatment outcomes were better in the PA-RPD group than the C-RPDs. Women showed greater concern for the treatment outcomes; their rates were significantly better than in male patients in the PA-RPD group; however, when their satisfaction was lower, their rates were significantly worse than in male patients (in the C-RPD group). © 2015 by the American College of Prosthodontists.

  6. Skeletal response to maxillary protraction with and without maxillary expansion: a finite element study.

    Science.gov (United States)

    Gautam, Pawan; Valiathan, Ashima; Adhikari, Raviraj

    2009-06-01

    The purpose of this finite element study was to evaluate biomechanically 2 treatment modalities-maxillary protraction alone and in combination with maxillary expansion-by comparing the displacement of various craniofacial structures. Two 3-dimensional analytical models were developed from sequential computed tomography scan images taken at 2.5-mm intervals of a dry young skull. AutoCAD software (2004 version, Autodesk, San Rafael, Calif) and ANSYS software (version 10, Belcan Engineering Group, Cincinnati, Ohio) were used. The model consisted of 108,799 solid 10 node 92 elements, 193,633 nodes, and 580,899 degrees of freedom. In the first model, maxillary protraction forces were simulated by applying 1 kg of anterior force 30 degrees downward to the palatal plane. In the second model, a 4-mm midpalatal suture opening and maxillary protraction were simulated. Forward displacement of the nasomaxillary complex with upward and forward rotation was observed with maxillary protraction alone. No rotational tendency was noted when protraction was carried out with 4 mm of transverse expansion. A tendency for anterior maxillary constriction after maxillary protraction was evident. The amounts of displacement in the frontal, vertical, and lateral directions with midpalatal suture opening were greater compared with no opening of the midpalatal suture. The forward and downward displacements of the nasomaxillary complex with maxillary protraction and maxillary expansion more closely approximated the natural growth direction of the maxilla. Displacements of craniofacial structures were more favorable for the treatment of skeletal Class III maxillary retrognathia when maxillary protraction was used with maxillary expansion. Hence, biomechanically, maxillary protraction combined with maxillary expansion appears to be a superior treatment modality for the treatment of maxillary retrognathia than maxillary protraction alone.

  7. Successful removable partial dentures.

    Science.gov (United States)

    Lynch, Christopher D

    2012-03-01

    Removable partial dentures (RPDs) remain a mainstay of prosthodontic care for partially dentate patients. Appropriately designed, they can restore masticatory efficiency, improve aesthetics and speech, and help secure overall oral health. However, challenges remain in providing such treatments, including maintaining adequate plaque control, achieving adequate retention, and facilitating patient tolerance. The aim of this paper is to review the successful provision of RPDs. Removable partial dentures are a successful form of treatment for replacing missing teeth, and can be successfully provided with appropriate design and fabrication concepts in mind.

  8. A 3-year follow-up study of overdentures retained by mini-dental implants.

    Science.gov (United States)

    Preoteasa, Elena; Imre, Marina; Preoteasa, Christina Teodora

    2014-01-01

    This study evaluated overdentures retained by mini-dental implants (MDIs) as a treatment option for complete edentulism during a 3-year follow-up period. This observational clinical study included completely edentulous patients who were treated with MDI-retained overdentures. The MDIs were supplied by the manufacturer. Twenty-three patients received 7 maxillary and 16 mandibular MDI overdentures retained by 110 MDIs. Of the 36 MDIs placed in the maxilla, 8 failed (in two patients), 2 had compromised survival, 3 displayed satisfactory survival, and 23 were successful. Of the 74 MDIs placed in the mandible, 11 displayed satisfactory survival and 63 were successful. The marginal bone loss was more pronounced for the MDIs placed mesially (intercalated), in areas of decreased ridge width and bone density, and with lower values of insertion torque. The overdentures fractured in seven patients; in 4 of them, this corresponded to the implant housing area. Self-reported reasons for patient dissatisfaction included occasional pain under the overdenture (n = 5) and instability of the maxillary antagonist complete denture (n = 4). Based on this research, considering its limitations, it is possible to conclude that survival rates and health status are better for MDI overdentures applied in the mandible than for those applied in the maxilla. The most severe prosthetic complications encountered were overdenture base fracture, matrix detachment, and instability of the maxillary antagonist denture.

  9. Effects of maxillary sinus floor elevation surgery on maxillary sinus physiology

    NARCIS (Netherlands)

    Timmenga, NM; Raghoebar, GM; Liem, RSB; van Weissenbruch, R; Manson, WL; Vissink, A

    In a prospective study, the effects of elevation surgery of the maxillary sinus floor on maxillary sinus physiology were assessed. Seventeen consecutive patients without preoperative anamnestic, clinical and radiological signs of maxillary sinusitis underwent sinus floor elevation surgery with iliac

  10. Alveolar ridge rehabilitation to increase full denture retention and stability

    OpenAIRE

    Mefina Kuntjoro; Rostiny Rostiny; Wahjuni Widajati

    2010-01-01

    Background: Atrophic mandibular alveolar ridge generally complicates prostetic restoration expecially full denture. Low residual alveolar ridge and basal seat can cause unstable denture, permanent ulcer, pain, neuralgia, and mastication difficulty. Pre-proshetic surgery is needed to improve denture retention and stability. Augmentation is a major surgery to increase vertical height of the atrophic mandible while vestibuloplasty is aimed to increase the denture bearing area. Purpose: The augme...

  11. 21 CFR 872.3300 - Hydrophilic resin coating for dentures.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrophilic resin coating for dentures. 872.3300... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3300 Hydrophilic resin coating for dentures. (a) Identification. A hydrophilic resin coating for dentures is a device that consists of a water...

  12. The adhesive strength and initial viscosity of denture adhesives.

    Science.gov (United States)

    Han, Jian-Min; Hong, Guang; Dilinuer, Maimaitishawuti; Lin, Hong; Zheng, Gang; Wang, Xin-Zhi; Sasaki, Keiichi

    2014-11-01

    To examine the initial viscosity and adhesive strength of modern denture adhesives in vitro. Three cream-type denture adhesives (Poligrip S, Corect Cream, Liodent Cream; PGS, CRC, LDC) and three powder-type denture adhesives (Poligrip Powder, New Faston, Zanfton; PGP, FSN, ZFN) were used in this study. The initial viscosity was measured using a controlled-stress rheometer. The adhesive strength was measured according to ISO-10873 recommended procedures. All data were analyzed independently by one-way analysis of variance combined with a Student-Newman-Keuls multiple comparison test at a 5% level of significance. The initial viscosity of all the cream-type denture adhesives was lower than the powder-type adhesives. Before immersion in water, all the powder-type adhesives exhibited higher adhesive strength than the cream-type adhesives. However, the adhesive strength of cream-type denture adhesives increased significantly and exceeded the powder-type denture adhesives after immersion in water. For powder-type adhesives, the adhesive strength significantly decreased after immersion in water for 60 min, while the adhesive strength of the cream-type adhesives significantly decreased after immersion in water for 180 min. Cream-type denture adhesives have lower initial viscosity and higher adhesive strength than powder type adhesives, which may offer better manipulation properties and greater efficacy during application.

  13. The effect of full denture on memory and depression status in elderly

    Directory of Open Access Journals (Sweden)

    Bahruddin Thalib

    2016-06-01

    Full Text Available Complaint that is most often found in elderly is declining or disappearing memory and tooth loss due to aging. Loss of teeth will cause a disturbance in the function of mastication and reportedly may also contribute to the occurrence of memory disorders and depression. The objective of this study was to analyze the influence of full denture use on memory capacity and depression level in elderly. Study conducted at Oral and Dental Hospital Faculty of Dentistry, University of Hasanuddin. This study was clinical experimental with non-randomized design with pre and post test. Sampling with purposive sampling technique, and there were 6 people who are willing to participate. Memory status measurement using Mini-Mental State Exam (MMSE and level of depression using Geriatric Depression Scale (GDS. Memory status and level of depression measurement performed before using full denture and one month after using full denture. Data were analyzed with statistical pair T-test. With a 95% confidence level, the results showed there is an increase in initial MMSE average value (25.67 to the final MMSE average value (26.83 with statistically significant effect, p 0,05. This study concluded that there was significant influence in using full denture on improved memory status of complete edentulous elderly, and despite there were decreased on level of depression, but it was not statistically significant.

  14. [Oral mucosa reaction in patients adapting to removable dentures].

    Science.gov (United States)

    Iordanishvili, A K; Soldatova, L N; Pihur, O L; Mihajlova, E S; Peremyshlenko, A S; Soldatov, V S

    Oral mucosa reaction of prosthetic bed to the removable acrylic dentures was evaluated in 43 patients (12 male and 31 female) aged 56-69 years with partial and full teeth loss in one or both jaws. Patients of the first (control) group (17 patients) were not using additional tools improving fixation of the removable dentures during adaptation period, while patients of the second (main) group (26 patients) used Corega cream for dentures fixation for 30 days follow-up. Oral mucosa assessment was carried out on 3-4 and 28-30 day of dentures use by 3 end points: pain syndrome, moisture level, inflammation of a prosthetic bed. The results proved Corega cream to improve prosthetic bed mucosa condition reducing inflammatory response to polymeric materials of removable dentures basis.

  15. A review of computer-aided design/computer-aided manufacture techniques for removable denture fabrication

    Science.gov (United States)

    Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan

    2016-01-01

    The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. PMID:27095912

  16. The effect of denture adhesives on Candida albicans growth in vitro.

    Science.gov (United States)

    Sampaio-Maia, Benedita; Figueiral, Maria Helena; Sousa-Rodrigues, Patricia; Fernandes, Maria Helena; Scully, Crispian

    2012-06-01

    Denture-wearing favours the growth of Candida. In view of the fact that many denture wearers regularly use adhesives to enhance denture retention, stability and function, the aim of this work was to study the effect of denture adhesives on Candida albicans growth in vitro. The denture adhesives tested were Corega(®) cream, Kukident(®) cream, Novafix(®) cream, Polident(®) cream, Protefix(®) cream, Steradent(®) cream, Aderyn(®) powder, Corega(®) ultra powder, Protefix(®) powder and Corega(®) strip. C. albicans growth curves were obtained in the presence or absence of a 1% solution of the denture adhesive diluted in Sabouraud broth. Macro- and microscopic morphological changes in C. albicans were analysed, as was microbial contamination of the denture adhesive. Most of the denture adhesives studied induced morphological changes in C. albicans cells and colonies, but only two had any significant inhibitory effect on yeast growth. Kukident(®) cream markedly inhibited C. albicans growth in a concentration-dependent way, reducing the growth rate by 95%, whereas Corega(®) cream also inhibited C. albicans growth but in a non-concentration-dependent way, reducing the growth rate by 37%. In addition, denture adhesives available as powders had detectable microbial contamination. Some commercially available denture adhesives showed microbial contamination and some had significant inhibitory effect on C. albicans growth. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  17. Surgical Splint Design Influences Transverse Expansion in Segmental Maxillary Osteotomies

    DEFF Research Database (Denmark)

    Stokbro, Kasper; Aagaard, Esben; Torkov, Peter

    2017-01-01

    splint designs on achieving the planned transverse expansion in bimaxillary surgery with segmental maxillary procedures. Materials and Methods: Forty-two participants were included in a retrospective observational study. All participants had completed virtually planned bimaxillary surgery with 3-piece......Purpose: In segmental maxillary procedures, it is imperative to obtain as much of the planned expansion as possible. Lack of obtained expansion, in addition to late relapse after splint removal, can result in relapse of the posterior crossbite. This study investigated the influence of 2 surgical...... maxillary segmentation. The primary outcome variable was the transverse expansion obtained, measured as the expansion between the maxillary first molars on preoperative and postoperative cone-beam computed tomograms. The postoperative scan was performed 1 week after surgery with the splint still in place...

  18. Anterior maxillary segmental distraction in the treatment of severe maxillary hypoplasia secondary to cleft lip and palate.

    Science.gov (United States)

    Li, Hongliang; Dai, Jiewen; Si, Jiawen; Zhang, Jianfei; Wang, Minjiao; Shen, Steve Guofang; Yu, Hongbo

    2015-01-01

    Anterior maxillary segmental distraction (AMSD) is an effective surgical procedure in the treatment of maxillary hypoplasia secondary to cleft lip and palate. Its unique advantage of preserving velopharyngeal function makes this procedure widely applied. In this study, the application of AMSD was described and its long-term stability was explored. Eight patients with severe maxillary hypoplasia secondary to CLP were included in this study. They were treated with AMSD using rigid external distraction (RED) device. Cephalometric analysis was performed twice at three time points for evaluation: before surgery (T1), after distraction (T2), and 2 years after treatment (T3). One-way analysis of variance was used to assess the differences statistically. All the distractions completed smoothly, and maxilla was distracted efficiently. The value of SNA, NA-FH, Ptm-A, U1-PP, overjet and PP (ANS-PNS) increased significantly after the AMSD procedure (P 0.05). Changes of palatopharyngeal depth and soft palatal length were insignificant. AMSD with RED device provided an effective way to correct maxillary hypoplasia secondary to CLP, extended the palatal and arch length, avoided damage on velopharyngeal closure function and reduced the relapse rate. It is a promising and valuable technique in this potentially complicated procedure.

  19. Manufacturing hollow obturator with resilient denture liner on post hemimaxillectomy

    Directory of Open Access Journals (Sweden)

    Michael Josef Kridanto Kamadjaja

    2006-03-01

    Full Text Available A resilient denture liner is placed in the part of the hollow obturator base that contacts to post hemimaxillectomy mucosa. Replacing the resilient denture liner can makes the hollow obturator has an intimate contact with the mucosa, so it can prevents the mouth liquid enter to the cavum nasi and sinus, also eliminates painful because of using the hollow obturator. Resilient denture liner is a soft and resilient material that applied to the fitting surface of a denture in order to allow a more distribution of load. A case was reported about using the hollow obturator with resilient denture liner on post hemimaxillectomy to overcome these problems.

  20. Space closure in the maxillary posterior area through the maxillary sinus.

    Science.gov (United States)

    Park, Jae Hyun; Tai, Kiyoshi; Kanao, Akira; Takagi, Masato

    2014-01-01

    A common dilemma in adult orthodontic treatment is deciding how best to treat missing posterior teeth. One treatment option is to orthodontically close the space. But closure can be difficult, especially if the open space is in the maxillary posterior area, because tooth movement through the maxillary sinus is limited. The increased difficulty of moving teeth in the maxillary sinus is similar to moving a tooth in the atrophic posterior mandibular ridge. If space closure is selected as a treatment method, proper mechanics and light forces should be applied. In this article, we report movement of teeth through the maxillary sinus and discuss various implications related to orthodontic treatment in the maxillary sinus. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  1. Rehabilitation of large maxillary defect with two-piece maxillary obturators

    Directory of Open Access Journals (Sweden)

    Kanchan P Dholam

    2015-01-01

    Full Text Available The insertion and removal of an obturator in large maxillary defects with or without trismus is difficult. Fabrication of a two-piece obturator in such cases overcomes this problem. This article describes rehabilitation of large maxillary defects with two piece maxillary obturator of three types. All these obturators have a maxillary plate and a bulb component, which are approximated together by various techniques namely, silicone cover, embedded magnets, and press studs. Prosthetic rehabilitation of large maxillary defects with two-piece obturators offers the possibility of adequate oral rehabilitation by fabricating light weight prosthesis, which is easy to use. The bulb covers the undercut areas of the defect enhancing the facial contour and retention. It facilitates easy examination of underlying tissues, recreation of the anatomic barrier between the oral and nasal cavities and restoration of the function and esthetics. Thus, it adds to the quality of life.

  2. Oral health-related quality of life in patients treated by implant-supported fixed dentures and removable partial dentures.

    Science.gov (United States)

    Furuyama, Chisako; Takaba, Masayuki; Inukai, Mika; Mulligan, Roseann; Igarashi, Yoshimasa; Baba, Kazuyoshi

    2012-08-01

    This study investigated the association between denture status [implant-supported fixed dentures (IDs) and removable partial dentures (RPDs)] and oral health-related quality of life (OHRQoL). Consecutive patients with IDs and RPDs were recruited from the Prosthodontics Departments at Showa University and Tokyo Medical and Dental University. The Japanese version of the Oral Health Impact Profile (OHIP-J-49) was administered to each subject. For each OHIP-J-49 question, the subjects were asked to indicate the frequency with which they had experienced a dental problem during the last month. Responses were recorded on a 5 point Likert rating scale, with 0 being never and 4, very often. Summary scores were calculated and regression analyses conducted to investigate the association between denture status and OHIP-J-49 summary score. In total 79 ID subjects (mean age±SD of 51.7±12.4 years, 44.3% men) and 109 RPD subjects (mean age of 66.5±8.6 years, 30% men) participated after giving informed consent. The regression analysis between the type of treatment and the OHIP-J-49 summary score revealed a significant association with a coefficient of 17.0 (Confidence interval, CI: 10.9-23.1). When age and duration of denture usage, which had significant associations with OHIP-J-49, were included in this model, the regression coefficient remained virtually unchanged at 17.4 (CI: 9.75-25.0), thus indicating little potential confounding by them. OHRQoL in patients with implant-supported fixed dentures is generally less impaired than it is in those patients with RPDs. © 2011 John Wiley & Sons A/S.

  3. Presence of Different Candida Species at Denture Wearers With Type 2 Diabetes and Clinically Healthy Oral Mucosa-Pilot Study

    Directory of Open Access Journals (Sweden)

    Petrović Sanja Matić

    2018-03-01

    Full Text Available Background/Aim: The aim of this study was to examine prevalence of different Candida spp. at diabetics and nondiabetics wearing dentures without clinical signs of Denture Stomatitis (DS and to study if some local and systematic factors are confounders for harboring Candida at these subjects. Material and Methods: Total of 60 subjects wearing partial or complete upper acrylic denture having at least half of palatal mucosa covered by denture were selected and stratified into three experimental groups: systematically health subjects; patients with diagnosed Type 2 Diabetes (T2D and good glycoregulation; and T2D subjects with poorly regulated blood sugar level. Cotton swab samples were obtained from each patient from hard palate mucosa and denture surface. Swab cultures were made on Sabouraud dextrose agar and ChromAgar Media for distinciton of various Candida spp. Density growth was also measured. Results: Frequency of Candida spp. findings were similar between groups. At healthy subjects, only C.albicans was detected. At diabetics, C.albicans was the most common isolated species, followed by C.glabrata and C.tropicalis. Negative finding of yeasts on palatal mucosa, but positive on denture surface were detected at all groups, with the highest frequency (33.4% at diabetics with poor glycoregulation. Denture surface was heavier colonized than hard palate mucosa. Duration of diabetes in years were only independent predictors for harboring Candida spp. at denture surface (Exp B=1.186, CI=1.047-1.344, p=0.007. Conclusions: Prosthesis of denture wearers without DS may serve as reservoir of Candida spp. Presence of more pathogenic and resistant non-albicans species are related to diabetics, even without clinical signs of DS.

  4. Kinesiographic study of complete denture movement related to mucosa displacement in edentulous patients Estudo cinesiográfico da movimentação da prótese total resultante da deformação da fibromucosa em desdentados totais

    Directory of Open Access Journals (Sweden)

    Marco Antonio Compagnoni

    2003-12-01

    Full Text Available The mucosa that covers the residual ridges of edentulous patients may present some distortion or displacement when occlusal loading is applied in complete dentures. This distortion and movement of the denture can result in acceleration of residual ridge resorption and loss of retention and stability. The aim of this study was to analyze the pattern of upper complete denture movement related to underlying mucosa displacement. A sample of 10 complete denture wearers was randomly selected, which had acceptable upper and lower dentures and normal volume and resilience of residual ridges. The kinesiographic instrument K6-I Diagnostic System® was used to measure denture movements, according to the method proposed by Maeda et al.7, 1984. Denture movements were measured under the following experimental conditions: (A 3 maximum voluntary clenching cycles and (B unilateral chewing for 20 seconds. The results showed that under physiological load, oral mucosa distortion has two distinct phases: a fast initial displacement as load is applied and a slower and incomplete recovery when load is removed. Intermittent loading such as chewing progressively reduces the magnitude of the denture displacement and the recovery of the mucosa is gradually more incomplete.Devido às características de compressibilidade da fibromucosa, a incidência de cargas sobre a prótese total resulta na movimentação da prótese em direção ao rebordo, a qual pode resultar no aumento da reabsorção do rebordo residual, na desadaptação interna e na perda de retenção da prótese. O objetivo do presente estudo é avaliar o padrão de movimentação da prótese total superior em função da deformação da fibromucosa. Foram selecionados 10 pacientes usuários de próteses totais bimaxilares, com retenção satisfatória e relações oclusais corretas e rebordos alveolares com volume e grau de resiliência normais. Para a análise da movimentação da prótese total superior foi

  5. Flexible removable partial dentures: a basic overview.

    Science.gov (United States)

    Hill, Edward E; Rubel, Barry; Smith, John B

    2014-01-01

    For many years, flexible resin materials have been available for fabricating removable partial denture (RPD) prostheses. Using a nonrigid material for the major connector or other components of an RPD may be a consideration for certain patients. Except for the promotional literature that has been written for flexible resin dentures, there is very little information available in the dental literature concerning nonrigid RPDs. As a result, the decision to use this treatment option depends on the judgment and experience of the dentist and fabricating laboratory. This article summarizes clinically pertinent information about flexible, nonrigid partial dentures.

  6. Differences in Lip Support with and without Labial Flanges in a Maxillary Edentulous Population - Part 3: Unblinded and Discriminatory Subjective Analysis.

    Science.gov (United States)

    Bidra, Avinash S; Nguyen, Viensuong; Manzotti, Anna; Kuo, Chia-Ling

    2018-01-01

    To study the subjective differences in direct lip support assessments and to determine if dentists and laypeople are able to discern and correctly identify direct changes in lip support between flange and flangeless dentures. A random sample of 20 maxillary edentulous patients described in part 2 of the study was used for analysis. A total of 60 judges comprising 15 general dentists, 15 prosthodontists, and 30 laypeople, the majority of who were distinct from part 2 of the study, were recruited. All images used in this study were cropped at the infraorbital level and converted to black and white tone, to encourage the judges to focus on lip support. The judges were un-blinded to the study objectives and told what to look for, and were asked to rate the lip support of each of the 80 images on a 100 mm visual analog scale (VAS). The judges then took a discriminatory sensory analysis test (triangle test) where they were required to correctly identify the image with a flangeless denture out of a set of 3 images. Both the VAS and triangle test ratings were conducted twice in a random order, and mean ratings were used for all analyses. The overall VAS ratings of lip support for images with flangeless dentures were slightly lower compared to images with labial flanges, and this difference was statistically significant (p differences was too small (no greater than 5 mm on a 100-mm scale) to be clinically significant or meaningful. The differences in VAS ratings were not significant between the judges. For the triangle test, judges overall correctly identified the flangeless denture image in 55% of frontal image sets and 60% of profile image sets. The difference in correct identification rate between frontal and profile images was statistically significant (p difference in correct identification rate was statistically significant between various judges (p = 0.012). For all judges, the likelihood of correctly identifying images with flangeless dentures was significantly

  7. Maxillary Hypoplasia With Congenital Oligodontia Treated by Maxillary Distraction Osteogenesis.

    Science.gov (United States)

    Mishima, Sayaka; Yamaguchi, Takako; Watanabe, Takuma; Komatani, Toru; Nakao, Kazumasa; Takahashi, Katsu; Bessho, Kazuhisa

    2018-02-27

    It is known that congenitally missing teeth can often cause differences in craniofacial morphology; however, there are few reported cases of orthognathic surgical treatment for these patients. Herein, the authors report a rare case of maxillary hypoplasia with congenital oligodontia treated by maxillary distraction osteogenesis with internal device. A 17-year-old male presenting with multiple tooth agenesis and maxillary recession was referred to our hospital for orthognathic surgical treatment. Preoperative simulation surgery was performed using Full-Color 3-dimensional salt model. After surgery, improvement in maxillary recession and occlusal stability was observed. This report demonstrates the advantages of the method used herein, which includes reduction in operating time with increase in the safety of the procedure.

  8. Evaluation of gloss changes of two denture acrylic resin materials in four different beverages.

    Science.gov (United States)

    Keyf, Filiz; Etikan, Ilker

    2004-03-01

    The primary disadvantages of the materials which are used in construction of complete and removable partial dentures is that their esthetic, physical and mechanical properties change rapidly with time in the oral environment. For esthetics, color stability is one of the criteria that needs careful attention. Color may provide important information on the serviceability of these materials. Color change affects the gloss of these materials. The objective of the present study was to determine the gloss changes resulting from the testing process in four different beverages in one heat-polymerized denture base resin and one cold-polymerized denture base repair resin. Thirty-six samples were fabricated for each material. Each sample had a smooth polished and a rough unpolished surface. The gloss measurements were made with a glossmeter before testing. Four different beverages (tea, coffee, cola and cherry juice) were used for testing. Two angles of illumination (20 and 60 degrees) were used for the gloss measurements. The samples were immersed in water, tea, coffee, cola and cherry juice solutions. The gloss of the samples was measured again with the glossmeter at the end of the 45th day and 135th day of testing. The arithmetic mean and standard deviation of each of the samples were calculated and compared with each other statistically by using the Wilcoxon test (within times) (p gloss changes occurred after testing in heat-polymerized denture base resin and cold-polymerized denture base repair resin. The significance of the gloss changes exhibited by each sample, kept for different lengths of time in the same solution, were compared using the Wilcoxon test. The results were statistically significant (p 0.05), but the difference between smooth polished and rough unpolished surfaces was statistically significant (p gloss of heat-polymerized denture base resin or the gloss of cold-polymerized denture base repair resin was affected by tested agents, and the four beverages

  9. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    Science.gov (United States)

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD

  10. Removable partial denture on osseointegrated implants and natural teeth.

    Science.gov (United States)

    Chang, Li-Ching; Wang, Jen-Chyan; Tasi, Chi-Cheng

    2007-01-01

    Implants have been designed to provide edentulous patients with fixed prostheses or overdentures. Recently, implant-supported fixed partial prostheses and single crowns have become successful treatment alternatives to removable and fixed partial dentures. However, few researchers have examined "removable partial dentures on implants and natural teeth". In this article, we report two patients fitted with "removable partial dentures on implants and natural teeth". The patients were satisfied with their dentures in terms of function and aesthetics. Regular follow-up visits revealed that the periodontal and peri-implant conditions were stable. There was no evidence of excessive intrusion or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs. Since the average duration of observation was about 38 months, further follow-up examinations are necessary to determine whether these dentures remain stable long-term.

  11. Development of a digital impression procedure using photogrammetry for complete denture fabrication.

    Science.gov (United States)

    Matsuda, Takashi; Goto, Takaharu; Kurahashi, Kosuke; Kashiwabara, Toshiya; Ichikawa, Tetsuo

    We developed an innovative procedure for digitizing maxillary edentulous residual ridges with a photogrammetric system capable of estimating three-dimensional (3D) digital forms from multiple two-dimensional (2D) digital images. The aim of this study was to validate the effectiveness of the photogrammetric system. Impressions of the maxillary residual ridges of five edentulous patients were taken with four kinds of procedures: three conventional impression procedures and the photogrammetric system. Plaster models were fabricated from conventional impressions and digitized with a 3D scanner. Two 3D forms out of four forms were superimposed with 3D inspection software, and differences were evaluated using a least squares best fit algorithm. The in vitro experiment suggested that better imaging conditions were in the horizontal range of ± 15 degrees and at a vertical angle of 45 degrees. The mean difference between the photogrammetric image (Form A) and the image taken from conventional preliminarily impression (Form C) was 0.52 ± 0.22 mm. The mean difference between the image taken of final impression through a special tray (Form B) and Form C was 0.26 ± 0.06 mm. The mean difference between the image taken from conventional final impression (Form D) and Form C was 0.25 ± 0.07 mm. The difference between Forms A and C was significantly larger than the differences between Forms B and C and between Forms D and C. The results of this study suggest that obtaining digital impressions of edentulous residual ridges using a photogrammetric system is feasible and available for clinical use.

  12. Lost and found…Tracking a swallowed denture: Role of radiology

    Directory of Open Access Journals (Sweden)

    Yogita Khalekar

    2017-01-01

    Full Text Available Denture ingestion or aspiration is a problem requiring awareness of different specialists including dentists, surgeons, otolaryngologists, and anesthesiologists for prevention, early diagnosis and adequate treatment. Complications of swallowed dentures include hollow viscous necrosis, perforation, and penetration to neighbouring organs leading to fistulae, bleeding and obstruction. Here, we present the case of a 65 year old female patient who swallowed the denture, which was detected by barium swallow and removed by endoscopy. Hence, the management of swallowed denture needs a multidisciplinary approach with the help of a dentist, otolaryngologist and anesthesiologists. Dentists should recommend patients to visit them for planned check ups or revisit them in case of denture dislodgement or loosening as soon as possible to prevent such life threatening events.

  13. Expectations and satisfaction of denture patients in a university clinic.

    Science.gov (United States)

    Davis, E L; Albino, J E; Tedesco, L A; Portenoy, B S; Ortman, L F

    1986-01-01

    These results indicate that patients' expectations of dentures before treatment were unrealistically high and that informational videotapes did not significantly affect these expectations. Satisfaction with current dentures was surprisingly high before treatment and increased significantly from pretreatment to postreatment for both groups in the study. While it is likely that this increase in satisfaction reflects a change from poor to excellent denture status, this finding may also be attributed to cognitive dissonance theory; that is, high satisfaction may represent the means by which patients justify the expenses of their denture treatment. Although the videotape presentations did not alter the expectations of patients and their satisfaction with dentures, the tapes represent a potential source of accurate, standardized information for both patient and student dentist.

  14. [Routine oral examinations and specific after-care for removable partial dentures].

    Science.gov (United States)

    de Baat, C; Witter, D J; Keltjens, H M A M; Creugers, N H J

    2011-01-01

    Following treatment with a removable partial denture, routine oral examinations are required to stabilize the existing condition in a sustainable way and to make possible the timely treatment of anomalies which have appeared. In cases of problems assessed during a routine oral examination in relation to the removable partial dentures, maintenance, restorative and prosthetic treatment may be indicated. Maintenance treatments are indicated for small and easily retrievable alterations. In removable partial denture treatment, adequate space between prepared tooth and denture is essential. Possible prosthetic treatments of a removable partial denture are relining, rebasing, improving or renewing the maxillomandibular relation, repairment, and extension.

  15. Clinical and radiographic evaluation of maxillary central incisors exposure in patients undergoing maxillary advancement

    Directory of Open Access Journals (Sweden)

    Guilherme dos Santos Trento

    2015-12-01

    Full Text Available Abstract Introduction: Patients with dentofacial deformities may undergo orthodontic or orthodontic-surgical treatment. Both modalities can affect esthetics. Objective: This study aims to evaluate clinical and radiographic changes in exposure of maxillary central incisors occurring after orthognathic surgery for maxillary advancement. Methods: A total of 17 patients who underwent orthognathic surgery for maxillary advancement between September, 2010 and July, 2011 were selected. Exposure of maxillary central incisors was evaluated clinically and by lateral cephalograms. Measurements were taken one week before and three months after surgery. Data were paired in terms of sex, age, nasolabial angle, height and thickness of the upper lip, the amount of maxillary advancement, clinical exposure and inclination of maxillary central incisor by statistical tests (CI 95%. Results: After maxillary advancement, incisor clinical exposure had increased even with relaxed lips and under forced smile. Moreover, there was a mean increase of 23.33% revealed by lateral cephalograms. There was an inverse correlation between upper lip thickness and incisors postsurgical exposure revealed by radiographic images (p = 0.002. Conclusions: Significant changes in the exposure of maxillary central incisors occur after maxillary advancement, under the influence of some factors, especially lip thickness.

  16. Trans-sinusal maxillary distraction for correction of midfacial hypoplasia: long-term clinical results.

    Science.gov (United States)

    Nadjmi, N; Schutyser, F; Van Erum, R

    2006-10-01

    Maxillary distraction osteogenesis is indicated in severe angle class III malocclusions, and severe maxillary hypoplasia among some cleft patients and other craniofacial deformities. Twenty patients, aged 8-48 years (mean 17.8+/-10.5 SD) with maxillary and midfacial hypoplasia were treated. The follow-up period was 13-65 months (mean 35+/-16.3 SD). A trans-sinusal maxillary distractor was placed intraorally at each side of the maxilla. The distraction vector was predicted using specialist software, and was transferred to the patients using stereolithographic models and individual templates. A (high) Le Fort I type osteotomy was performed. The amount of activation varied from 8 to 17.5 mm (mean 13.1+/-2.9 SD). Soft and hard tissue formation resulted in complete healing across the distraction gaps. The distractors are almost completely submerged, and can be left in place as long as necessary to avoid relapse. Wit's appraisal was used to measure the stability of the long-term distraction results. Results up to 5 years after distraction showed considerable maxillary advancement with long-term stability. Ongoing growth of the facial skeleton must be considered when distraction osteogenesis is chosen in growing patients.

  17. Recent Advances and Future Perspectives for Reinforcement of Poly(methyl methacrylate Denture Base Materials: A Literature Review

    Directory of Open Access Journals (Sweden)

    Sahar Abdulrazzaq Naji

    2018-03-01

    Full Text Available Poly(methyl methacrylate (PMMA is the most common material used to fabricate complete and partial dentures. Despite its desirable properties, it cannot fulfill all mechanical requirements of prosthesis. Flexural fatigue due to repeated masticatory and high-impact forces caused by dropping are the main causes of denture fractures. In the past, different reinforcing agents such as rubbers, macro fibers, and fillers have been employed to improve the mechanical properties of denture base resins. Development of Nano dentistry has introduced new approaches for reinforcement of dental materials. Interest in nanostructure materials is driven by their high surface area to volume ratio, which enhances interfacial interaction and specific new biological, physical, and chemical properties. Researchers to reinforce PMMA resins have used Nanoparticles (Nps which were comprised of silver, Titania (TiO2, zirconia (ZrO2, alumina, and ceramic. Although different reports describe the use of nanofiber and nanotubes in dental composites, few studies have evaluated the reinforcement potential of nanofiber and nanotubes in PMMA denture base resins. The current article aims to review the different attempts to enhance the mechanical properties of denture base materials. We also focus on recent advances and potential future developments for reinforcement of the PMMA acrylic resins.

  18. Comparison of chewing ability, oral health related quality of life and nutritional status before and after insertion of complete denture amongst edentulous patients in a Dental College of Pune.

    Science.gov (United States)

    Madhuri, Sonawane; Hegde, Shetiya Sahana; Ravi, Shirahatti; Deepti, Agarwal; Simpy, Mahuli

    2014-07-01

    The relationship between tooth loss and nutritional intake is important. As people age, their diminished physical capacity and decreased income adversely affect their ability to maintain their teeth. The aim of the study was to assess and compare the chewing ability, oral health related quality of life and nutritional status before and after fabrication and insertion of complete denture amongst edentulous participants in a dental college. Non Randomized Intervention study. The study population consisted of 42 participants (16 females and 26 males), aged 50 years and above. Prior to commencement of the study, informed consent was obtained and validation and reliability test of the questionnaire were done. The data for chewing ability, GOHAI and nutritional status assessment was recorded at baseline, 3(rd), 6(th) and 12(th) month after denture fabrication and insertion. The statistical comparisons were performed by repeated measure ANOVA and Chi-square test. P valueNutritive value of food (protein, energy and fat) showed no significant difference over a period of 12 months (poral health related quality of life.

  19. ORAL HYGIENE OF PROSTHETIC DENTURE USER IN KODINGARENG ISLAND

    OpenAIRE

    NUR, NURUL KUSUMADEWI S.KG

    2008-01-01

    Objectives:to determine the level of oral hygiene for prosthetic denture user, especially for full-denture in Kodingareng Island. This researchincluded the distribution level of prosthetic denture user based on age and education.Methods: the method that used in this research is observational descriptive withcross sectional-studyas the research design. Variable result of the research determined in to 3, those are bad, middle, and good. Result:the highest percentage o...

  20. Impact of removable partial denture prosthesis on chewing efficiency

    Science.gov (United States)

    BESSADET, Marion; NICOLAS, Emmanuel; SOCHAT, Marine; HENNEQUIN, Martine; VEYRUNE, Jean-Luc

    2013-01-01

    Removable partial denture prostheses are still being used for anatomic, medical and economic reasons. However, the impact on chewing parameters is poorly described. Objectives The objective of this study was to estimate the impact of removable partial denture prosthesis on masticatory parameters. Material and Methods Nineteen removable partial denture prosthesis (RPDP) wearers participated in the study. Among them, 10 subjects were Kennedy Class III partially edentulous and 9 with posterior edentulism (Class I). All presented a complete and full dentate opposing arch. The subjects chewed samples of carrots and peanuts with and without their prosthesis. The granulometry of the expectorated boluses from carrot and peanuts was characterized by median particle size (D50), determined at the natural point of swallowing. Number of chewing cycles (CC), chewing time (CT) and chewing frequency (CF=CC/CT) were video recorded. Results With RPDP, the mean D50 values for carrot and peanuts were lower [Repeated Model Procedures (RMP), F=15, p<0.001] regardless of the type of Kennedy Class. For each food, mean CC, CT and CF values recorded decreased (RMP, F=18, F=9, and F=20 respectively, p<0.01). With or without RPD, the boluses' granulometry values were above the masticatory normative index (MNI) determined as 4,000 µm. Conclusion RPDP rehabilitation improves the ability to reduce the bolus particle size, but does not reestablish fully the masticatory function. Clinical relevance This study encourages the clinical improvement of oral rehabilitation procedure. PMID:24212983

  1. Implant-supported mandibular removable partial dentures; patient-based outcome measures in relation to implant position.

    Science.gov (United States)

    Jensen, Charlotte; Raghoebar, Gerry M; Kerdijk, Wouter; Meijer, Henny J A; Cune, Marco S

    2016-12-01

    To assess the benefits of implant support to Removable Partial Dentures (RPD) in patients with a bilateral free-ending situation in the mandible and to determine the most favorable implant position: the premolar (PM) or the molar (M) region. Thirty subjects with a bilateral unbounded posterior saddle received 2 PM and 2M implants. A new RPD was placed. Implant support was provided 3 months later. Two PM implants supported the RPD. After 3 months the 2M implants were used or vice versa. Outcome measures included oral health related quality of life (OHIP-NL49), general health status (SF-36), contentment assessed on a Visual Analogue Scale (VAS) and the number of hours that the RPD was worn. Data were collected prior to treatment, 3 months after having functioned with a new RPD and after 3 and 6 months with implant support. Finally, patients expressed their preferred implant position. The general health status (SF-36) was not influenced. OHIP-NL49 values and mean wearing-time were statistical significantly more favorable for ISRPD's, regardless of the implant position. Per day, the ISRPD's were worn 2-3h more than the unsupported new RPD. Patients' expectations were met as the VAS-scores of anticipated and realized contentment did not reach a statistical significant level (p>0.05). VAS scores for ISRPD's with M implant support were higher than for PM implant support. Finally, 56.7% of subjects preferred the M implant support, 13.3% expressed no preference and 30% opted for PM implant support. Mandibular implant support favorably influences oral health related patient-based outcome measures in patients with a bilateral free-ending situation. The majority of patients prefer the implant support to be in the molar region. Patients with a bilateral free-ending situation in the mandible opposed by a maxillary denture benefit from implant support to their mandibular removable partial denture. Most patients prefer this support to be in the molar region. Copyright © 2016

  2. Evaluation of efficacy of commercial denture cleansing agents to reduce the fungal biofilm activity from heat polymerized denture acrylic resin: An in vitro study

    Directory of Open Access Journals (Sweden)

    Mithilesh M Dhamande

    2012-01-01

    Full Text Available Aims: To compare and evaluate Candida removing effects of three most commonly available varieties of commercial denture cleansers from heat polymerized acrylic resins. To compare and evaluate Candida lytic effects of denture cleansers. To assess the effect of time on ability of denture cleansers in reducing Candidal biofilm. Materials and Methods: A specially designed metal mold was fabricated to obtain wax plates of uniform dimensions which were used to fabricate heat cure acrylic resin plates. A square-shaped window of dimension 15 mm and thickness of 1.5 mm was provided in metal mould to simulate thickness of denture base. All samples used in this study were prepared using this mould. Candida albicans colonies were then cultured on this acrylic resin plates by colonization assay. Yeast removing test for samples was performed using microscope and yeast lytic test was performed using photo colorimeter. Results: Denture cleanser D2 showed the highest Candida removing activity when compared with cleansers D1, D3, and control solution. Denture cleansers D2 showed increased yeast lytic ability when compared with denture cleansers D1, D3, and control solution. More time span shared a definite influence on yeast lytic ability of denture cleansers. Conclusions: The effect of cleansing agents on removal of colonized yeasts particularly fungal biofilm from acrylic resins was assessed for clinical implications. The observation indicated superior performance of cleanser D2 when compared with D1 and D3 even though they all belong to same chemical group of alkaline peroxide. The increased effectiveness may be due to presence of sodium lauryl sulphate in formula of D2.

  3. Ecology of Candida-associated Denture Stomatitis

    OpenAIRE

    Budtz-Jørgensen, Ejvind

    2011-01-01

    Introduction of a prosthesis into the oral cavity results in profound alterations of the environmental conditions as the prosthesis and the underlying mucosa become colonized with oral microorganisms, including Candida spp. This may lead to denture stomatitis, a non-specific inflammatory reaction against microbial antigens, toxins and enzymes produced by the colonizing microorganisms. The role of Candida in the etiology of denture stomatitis is indicated by an increased number of yeasts on th...

  4. Developing a software for removable partial denture design: Part II: Introduction of RPD graph software

    Directory of Open Access Journals (Sweden)

    Nejatidanesh F

    2007-06-01

    Full Text Available Background and Aim: Designing removable partial dentures is one of the most important phases of prosthetic treatments. Computer can be used to facilitate and increase accuracy of removable partial denture design. The aim of this study was to develop a software for removable partial denture design.Materials and Methods: A questionnaire (discussed in part I and major textbooks, were used to determine the design rules.  The software (RPD Graph was developed using Visual C++ and Maryam program. The RPD Graph can determine the classification of partial edentulous arch. With defining the missing teeth and providing data about prognosis and conditions of abutment teeth, the removable partial design will be developed by RPD Graph. This software is a knowledge-based system which has specific characteristics. It can be used as an educational tool for teaching RPD design and as a clinical tool for supporting clinician's decision. In addition it can be developed to more complete softwares.

  5. Long-term results of surgically-assisted maxillary protraction.

    Science.gov (United States)

    Nevzatoğlu, Sirin; Küçükkeleş, Nazan

    2014-05-01

    The long-term treatment results of surgically-assisted facemask therapy were assessed by a comparison of the immediate protraction effects with those seen at five years review. Nine patients treated with a corticotomy-assisted maxillary protraction protocol were recalled five years following protraction. Cephalometric films taken before treatment (T0), immediately after maxillary protraction (T1) and five years after treatment (T2) were compared. The short-term results of surgically-assisted facemask therapy showed significant skeletal and soft tissue changes. After five years, the profile and dental relationships were well maintained and a cephalometric analysis revealed a stable vertical increase but only partially maintained soft tissue changes with loss of sagittal advancement. There was significant upper incisor proclination providing dental camouflage. Patients who are treated with corticotomy-assisted maxillary advancement should be very carefully selected. Assessment criteria include a low mandibular plane angle Class III patients who have severe maxillary retrognathism unable to be treated by conventional orthopaedic correction alone; patients who have almost completed growth and missed the chance of earlier orthopaedic correction, as well as patients who are not willing to accept bimaxillary orthognathic surgery, may be successfully treated.

  6. Does Andrews facial analysis predict esthetic sagittal maxillary position?

    Science.gov (United States)

    Resnick, Cory M; Daniels, Kimberly M; Vlahos, Maryann

    2018-04-01

    Cephalometric analyses have limited utility in planning maxillary sagittal position for orthognathic surgery. In Six Elements of Orofacial Harmony, Andrews quantified maxillary position relative to forehead projection and angulation and proposed an ideal relationship. The purpose of this study was to investigate the ability of this technique to predict esthetic sagittal maxillary position. Survey study including a male and female with straight facial profiles, normal maxillary incisor angulations, and Angle's Class I. Maxillary position was modified on lateral photographs to create 5 images for each participant with incisor-goal anterior limit line (GALL) distances of -4, -2, 0, +2, and +4 mm. A series of health care professionals and laypeople were asked to rate each photo in order of attractiveness. A total of 100 complete responses were received. Incisor-GALL distances of +4 mm (41%) and +2 mm (40%) were most commonly considered "most esthetic" for the female volunteer (P < .001). For the male volunteer, there were 2 peak "most esthetic" responses: incisor-GALL distances of 0 mm (37%) and -4 mm (32%) (P < .001). Respondents considered maxillary incisor position 2 to 4 mm anterior to GALL most attractive in a woman and 0 to 4 mm posterior to GALL most esthetic in a man. Using these modified target distances, this analysis may be useful for orthognathic surgery planning. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Truncal anaesthesia of the maxillary nerve for outpatient surgically assisted rapid maxillary expansion.

    Science.gov (United States)

    Robiony, M; Demitri, V; Costa, F; Politi, M; Cugini, U

    1998-10-01

    We present our experience of transcutaneous truncal anaesthesia of the maxillary nerve in association with transmucosal anaesthesia of the sphenopalatine ganglion in surgically assisted rapid maxillary expansion. Twelve patients with a skeletal transverse discrepancy of the maxilla were treated in our department from 1994 to 1995. Maxillary transcutaneous nerve block was done with a Quincke 8 cm spinal needle together with transmucosal anaesthesia of the sphenopalatine ganglion. Mepivacaine without adrenaline and sodium bicarbonate 1/10 was used for truncal anaesthesia and lidocaine-prilocaine cream for transmucosal anaesthesia. A Le Fort I osteotomy, lateral nasal wall osteotomy, pterygomaxillary osteotomy, and a palatal osteotomy were done for all patients before the maxillary expansion. Total anaesthesia of the maxillary area facilitated the operations and appreciably reduced the amount of postoperative pain. The ease of achieving effective anaesthesia before and after operation and the absence of side-effects make this form of anaesthetic particularly useful in surgically assisted rapid maxillary expansion.

  8. Maxillary hematocele

    International Nuclear Information System (INIS)

    Inaba, Tsuyoshi; Fujimura, Takeyuki; Udaka, Tsuyoshi; Siomori, Teruo; Kadokawa, Yohei; Suzuki, Hideaki

    2007-01-01

    Hematocele is a benign hemorrhagic pseudotumor that preferably arises in the sinonasal tract, particularly in the maxillary sinus. The occurrence of maxillary hematocele has sporadically been documented, but its nature is not dearly understood. We herein report four cases of maxillary hematocele. The patients were 3 men and one woman, 30-62 years of age with an average of 49.8 years. Major symptoms were nasal obstruction (2 cases), nasal bleeding (2 cases), and toothache (1 case). Computed tomography demonstrated well-defined expansive soft tissue shadows with bone erosion. The lesions showed intermingled high/intermediate/low intensity in both T1- and T2-weighted magnetic resonance imaging. Endoscopic sinus surgery was performed in 3 cases, and the other patient underwent Caldwell-Luc procedure. Surgical specimens microscopically exhibited inflammatory changes with hematoma and fibrin deposition. The postoperative clinical course was uneventful in all cases, and all the patients are currently free from disease 4-25 months after surgery. Clinical, histopathological and radiological characteristics of maxillary hematocele are reviewed. (author)

  9. Tensile and shear bond strength of hard and soft denture relining materials to the conventional heat cured acrylic denture base resin: An In-vitro study.

    Science.gov (United States)

    Lau, Mayank; Amarnath, G S; Muddugangadhar, B C; Swetha, M U; Das, Kopal Anshuraj Ashok Kumar

    2014-04-01

    The condition of the denture bearing tissues may be adversely affected by high stress concentration during function. Chairside Denture (Hard and Soft) reliners are used to distribute forces applied to soft tissues during function. Tensile and shear bond strength has been shown to be dependent on their chemical composition. A weak bond could harbor bacteria, promote staining and delamination of the lining material. To investigate tensile and shear bond strength of 4 different commercially available denture relining materials to conventional heat cured acrylic denture base resin. 4 mm sections in the middle of 160 Acrylic cylindrical specimens (20 mm x 8 mm) were removed, packed with test materials (Mollosil, G C Reline Soft, G C Reline Hard (Kooliner) and Ufi Gel Hard and polymerized. Specimens were divided into 8 groups of 20 each. Tensile and shear bond strength to the conventional heat cured acrylic denture base resin were examined by Instron Universal Tensile Testing Machine using the equation F=N/A (F-maximum force exerted on the specimen (Newton) and A-bonding area= 50.24 mm2). One-way ANOVA was used for multiple group comparisons followed by Bonferroni Test and Hsu's MCB for multiple pairwise comparisons to asses any significant differences between the groups. The highest mean Tensile bond strength value was obtained for Ufi Gel Hard (6.49+0.08 MPa) and lowest for G C Reline Soft (0.52+0.01 MPa). The highest mean Shear bond strength value was obtained for Ufi Gel Hard (16.19+0.1 MPa) and lowest for Mollosil (0.59+0.05 MPa). The Benferroni test showed a significant difference in the mean tensile bond strength and the mean shear bond strength when the two denture soft liners were compared as well as when the two denture hard liners were compared. Hsu's MCB implied that Ufi gel hard is better than its other closest competitors. The Tensile and Shear bond strength values of denture soft reliners were significantly lower than denture hard reliners. How to cite the

  10. The knowledge and attitude of general dentists toward denture adhesives in Tehran

    Directory of Open Access Journals (Sweden)

    Fakhri Hamidreza

    2009-01-01

    Full Text Available Background: The purpose of this study was to generate discussion and communication among a group of general dentists in Tehran on their viewpoints regarding denture adhesives. Have they accepted denture adhesive as a material to enhance denture retention, stability and function? Materials and Methods: In the summer of 2007, a questionnaire was mailed to 300 general dentists who were assigned with a random systematic sampling method from general dentists in Tehran. The questions were arranged in two parts of evaluating knowledge and attitude. In evaluation of knowledge, dentists were classified into groups of good, moderate, weak and lack of knowledge. In evaluation of attitude, dentists were classified into positive, moderate and negative groups. (Evaluating attitude was carried out in good and moderate groups of knowledge. Results: The study showed that 14%, 32% and 37% of the general dentists had respectively good, moderate and weak knowledge toward denture adhesive while 16.3% had no knowledge about this material. In evaluation of attitude through dentists with positive and moderate knowledge toward denture adhesive, 9.3%, 71.3% and 19.4% had respectively positive, moderate and negative attitude toward denture adhesive. The χ2 test showed a significant statistical relation between situation of knowledge and experiences of dentists. Discussion: This study demonstrated that the rate of knowledge of these 300 general dentists in Tehran towards denture adhesives has not been in a good situation. It is believed that denture adhesive be able to enhance the fitness of a denture and provide psychological relief to the patient. Dentists agreed that education, not only for practitioners but also for patients, would raise the advantageous features and reduce the misuse of denture adhesive. Education of the topic "Denture adhesive" should be more concerned in dental universities.

  11. Mechanical properties of denture base resins: An evaluation

    Directory of Open Access Journals (Sweden)

    Pooran Chand

    2011-01-01

    Conclusion: The heat cure denture base material D (Trevalon "HI" was the strongest and C (Trevalon was the weakest among all materials used in this study. The study showed that the deflection of various denture base resins (A to D increases proportionately with the increase in load.

  12. The effect of cleaning substances on the surface of denture base material.

    Science.gov (United States)

    Žilinskas, Juozas; Junevičius, Jonas; Česaitis, Kęstutis; Junevičiūtė, Gabrielė

    2013-12-11

    The aim of this study was to evaluate the effect of substances used for hygienic cleaning of dentures on the surface of the denture base material. Meliodent Heat Cure (Heraeus-Kulzer, Germany) heat-polymerized acrylic resin was used to produce plates with all the characteristics of removable denture bases (subsequently, "plates"). Oral-B Complete toothbrushes of various brush head types were fixed to a device that imitated tooth brushing movements; table salt and baking soda (frequently used by patients to improve tooth brushing results), toothpaste ("Colgate Total"), and water were also applied. Changes in plate surfaces were monitored by measuring surface reflection alterations on spectrometry. Measurements were conducted before the cleaning and at 2 and 6 hours after cleaning. No statistically significant differences were found between the 3 test series. All 3 plates used in the study underwent statistically significant (pbaking soda--the total reflection reduction was 4.82 ± 0.1%; among toothbrushes with toothpaste, the hard-type toothbrush had the greatest reflection-reducing effect--4.6 ± 0.05%, while the toothbrush with table salt inflicted the least damage (3.5 ± 0.16%) due to the presence of rounded crystals between the bristles and the resin surface. Toothbrushes with water had a uniform negative effect on the plate surface - 3.8 9 ± 0.07%. All substances used by the patients caused surface abrasion of the denture base material, which reduced the reflection; a hard toothbrush with toothpaste had the greatest abrasive effect, while soft toothbrushes inflicted the least damage.

  13. Antifungal Effect of Henna against Candida albicans Adhered to Acrylic Resin as a Possible Method for Prevention of Denture Stomatitis

    Science.gov (United States)

    Nawasrah, Amal; AlNimr, Amani; Ali, Aiman A.

    2016-01-01

    Denture stomatitis is a very common disease affecting the oral mucosa of denture wearers. The aim of this study was to measure the antifungal effect of henna against Candida albicans adhered to acrylic resin as a possible method for prevention of denture stomatitis. One-hundred-eighty acrylic plates were prepared of heat-cured acrylic denture resin. The specimens were divided into six groups of 30 samples each. The first group was only polymer and monomer following the conventional manufacturer instruction for processing complete dentures. The other five groups were processed by adding different concentration of Yamani henna powder (Harazi) to the polymer in a concentration of henna: polymer 1%, 2.5%, 5%, 7.5% and 10%, respectively. Samples were incubated in artificial saliva rich with Candida albicans at 37 °C, and the effect of henna on Candida albicans was evaluated in two different methods: semi-quantitative slide count and a culture-based quantitative assay (quantitative). Variation in the number of live Candida was observed with the increase in the concentration of Yamani henna powder. It was observed that the variation in live Candida, between control group and group B (concentration of Yamani henna powder was 1%), was statistically significant with a p-value of 0.0001. Similarly, variations in live Candida were significant, when the concentration of powder was 7.5% or 10% in contrast with control group and p-values were 0.0001 and 0.001 respectively. Adding henna to acrylic resin denture could be effective in controlling Candida albicans proliferation on the denture surface; however, its effects on the physical properties of acrylic resin denture need further studies. PMID:27223294

  14. Preoperative concurrent CBDCA chemotherapy and accelerated hyperfractionated radiotherapy for squamous cell carcinoma of the maxillary region

    International Nuclear Information System (INIS)

    Omura, Ken; Harada, Hiroyuki; Suzuki, Haruhiko; Takeuchi, Yosuke; Hatano, Kazuo; Togawa, Takashi

    2001-01-01

    Between 1994 and 2000, 28 patients with T3/T4 squamus cell carcinoma of the maxillary region (maxillary sinus, 22; maxillary gingiva, 4; maxillary bone, 1; buccal mucosa, 1) had accelerated hyperfractionated radiotherapy combined with simultaneous CBDCA chemotherapy preoperatively, at Chiba Cancer Center Hospital. The protocol consisted of combined therapy with accelerated hyperfractionated irradiation of 1.6 Gy, twice a day, to a total dose of 32.0-51.2 Gy and concurrent intra-arterial or intravenous infusion of CBDCA 20-30 mg/body/day for a cumulative total dose of 270-480 mg. After completion of the preoperative combined therapy, the clinical CR rate was 17.9%, and the good PR·CR rate was 32.1%. According to the initial findings and response to the combined therapy, all patients had maxillectomy (subtotal, 3; total, 16; extended, 9) 4 weeks after completion of the preoperative combined therapy. Postoperatively, the complete pathologic response (Ohboshi and Shimozato's classification, grade III and IV) rate was 28.6%. And the actuarial local control rate was 85.7%, with a mean follow-up of 46.2 months. Based on these results, we believe this preoperative therapy with CBDCA chemotherapy and accelerated hyperfractionated radiation is a significant choice as treatment for squamous cell cancer of the maxillary region. (author)

  15. Investigating oral health-related quality of life and self-perceived satisfaction with partial dentures.

    Science.gov (United States)

    Abuzar, Menaka A; Kahwagi, Esperance; Yamakawa, Takeshi

    2012-05-01

    To investigate the prevalence and severity of oral health-related quality of life in patients treated with removable partial dentures at a publicly-funded dental hospital. The association between patients' demographic profiles, denture-related, variables and oral health-related quality of life was also investigated. A questionnaire was designed to investigate the use and satisfaction of removable partial dentures, and oral health-related quality of life of removable partial denture wearers using the Oral Health Impact Profile-14. The questionnaire was administered to 740 randomly-selected patients who received removable partial dentures during 2005-2008. The response rate was 31.35%. Non-parametric tests and a logistic regression model were used to analyze the association between denture-related variables and oral health-related quality of life. A question on symptoms unrelated to dentures was also analyzed. The Oral Health Impact Profile-14 prevalence calculated was 43.1%. The removable partial denture experience and frequency of use was inversely associated with Oral Health Impact Profile-14 scores. Metal-based removable partial dentures were associated with lower Oral Health Impact Profile prevalence and severity scores. No significant association was found between demographic profile, circumstance for provision of removable partial dentures and Oral Health Impact Profile-14 score. The participants of this study indicated that perceived denture performance, removable partial dentures material, experience, and frequency of use are associated with oral health-related quality of life. © 2012 Blackwell Publishing Asia Pty Ltd.

  16. Tooth-Borne Anterior Maxillary Distraction for Cleft Maxillary Hypoplasia: Our Experience With 147 Patients.

    Science.gov (United States)

    Richardson, Sunil; Selvaraj, Dhivakar; Khandeparker, Rakshit V; Seelan, Nikkie S; Richardson, Shweta

    2016-12-01

    To evaluate the results of anterior maxillary distraction for its efficacy and long-term stability in the management of cleft maxillary hypoplasia in a large series of patients with a long-term follow-up extending to 4 years. One hundred sixty-four patients at least 10 years old with cleft maxillary hypoplasia who presented to the authors' unit from January 2009 through October 2014 were evaluated retrospectively, irrespective of gender, type of cleft lip and palate, and amount of advancement needed. Anterior maxillary distraction using a tooth-borne distractor appliance was carried out in all patients and all patients were followed up to 4 years (range, 1 to 4 yr) to evaluate the stability of the procedure and to document any relapse using digitalized lateral cephalograms taken before distraction, immediately after distraction (T2), and at the last follow-up visit (T3; range, 1 to 4 yr). Seventeen patients were subsequently lost to follow-up; therefore, a complete set of records was available for 147 patients. In a subset of 50 patients, perceptual speech assessment was carried out preoperatively and 6 months postoperatively by 2 speech pathologists using the Perkins scoring system that allowed the evaluation of 5 parameters (velopharyngeal insufficiency, resonance, nasal air emission, articulation, and intelligibility). None of these patients underwent speech therapy during the course of evaluation. The development of complications intra- or postoperatively was noted. The data were tabulated and analyzed. An advancement ranging from 4.0 to 13.1 mm (mean, 9.42 mm) was achieved in all patients. One hundred forty patients (95.23%) showed stable results on lateral cephalograms and when T2 values were compared with T3 values. Seven patients (4.76%) exhibited skeletal relapse in various linear and angular measurements assessed on lateral cephalograms. At 6-month follow-up, improvements of 62% (n = 31), 64% (n = 32), 50% (n = 25), 68% (n = 34), and 70% (n

  17. The single-tooth implant treatment of congenitally missing maxillary lateral incisors using angled abutments: A clinical report

    Directory of Open Access Journals (Sweden)

    Suleyman Hakan Tuna

    2009-01-01

    Full Text Available The maxillary lateral incisor is the second most common congenitally absent tooth. There are several treatment options for replacing the missing maxillary lateral incisor, including canine substitution, tooth-supported restoration, or single-tooth implant. Dental implants are an appropriate treatment option for replacing missing maxillary lateral incisor teeth in adolescents when their dental and skeletal development is complete. This case report presents the treatment of a patient with congenitally missing maxillary lateral incisors using dental implants with angled abutments.

  18. Impact of removable dentures on oral health-related quality of life among elderly adults in Taiwan.

    Science.gov (United States)

    Yen, Yea-Yin; Lee, Huey-Er; Wu, Yi-Min; Lan, Shou-Jen; Wang, Wen-Chen; Du, Je-Kang; Huang, Shun-Te; Hsu, Kun-Jung

    2015-01-05

    Although the use of removable dentures can improve oral function and esthetics for elderly people, compared to those who do not wear removable dentures, those wearing removable dentures could have worse oral health related-quality of life (OHRQoL). Additional information is required to assess which factors related to denture wearing influence the OHRQoL of elderly individuals. The purpose of this study is to evaluate the association between denture wearing and OHRQoL in a sample of elderly individuals in Taiwan. The study population included 277 elderly people wearing removable dentures (mean age = 76.0 years). Using face-to-face interviews, we collected data on the participants' socio-demographic characteristics, dental care service usage (regular dental checkups, treatment during toothache, dental visits in the last year), and factors related to denture wearing (perceived oral pain, perceived loose denture, perceived oral ulcer, perceived halitosis, perceived dry mouth, and perceived total denture satisfaction scores). OHRQoL was measured using the Taiwanese version of the Geriatric Oral Health Assessment Index (GOHAI-T). The location and number of remaining natural teeth and the type of denture were also recorded. Hierarchical multiple regression analysis was performed using GOHAI-T scores as the dependent variable. All the predictors together accounted for 50% of the variance in GOHAI-T scores. Further, education level, number of natural teeth, denture status, perceived loose denture, perceived oral ulcer, and perceived total denture satisfaction scores had statistically significant influences on OHRQoL. When compared with other variables, factors related to denture wearing, especially perceived total denture satisfaction scores, had the greatest impact on GOHAI-T scores. Of the factors analyzed in this study, denture satisfaction was the strongest predictor of OHRQoL. This suggests that denture satisfaction is useful for assessing the effect of denture

  19. Functional evaluation of a CAD/CAM prosthesis for immediate defect repair after total maxillectomy: a case series of 18 patients with maxillary sinus cancer.

    Science.gov (United States)

    Jiang, Fei-Fei; Hou, Yan; Lu, Li; Ding, Xiao-Xu; Li, Wei; Yan, Ai-Hui

    2015-01-01

    To evaluate the facial profiles and functional recovery of 18 patients treated by a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis) after total maxillectomy for malignant maxillary sinus tumor. A retrospective observational study was performed to evaluate the facial profiles and functional recovery of 18 patients with T3-4a N0 M0 maxillary sinus cancer, who were treated by total maxillectomy and simultaneous implantation of a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis). Follow-ups were performed 1, 3, 6, and 12 months after surgery. Facial measurements, speech intelligibility, and chewing and swallowing functions were examined. Thirteen patients converted to a permanent prosthesis 6 months after surgery. Comparisons were made between patients with and without the CAD/CAM or permanent prosthesis at various times using SPSS13.0 statistical software (SPSS Inc., Chicago, IL, USA). Speech intelligibility, facial depression, and eyeball prolapse results showed improvements with prosthesis use at 1, 3, and 6 months after surgery (p maxillectomy. This surgical treatment of maxillary sinus cancer is applied rarely in China, but it has a good effect based on our observation. Simultaneous CAD/CAM prosthesis implantation after total maxillectomy can recover the facial profile, enhance the speaking, swallowing, and chewing functions, and improve the quality of life of patients. Tumor recurrence can be detected by direct observation of the postoperative maxillary cavity. This technique avoids the need for dental implants because the bottom part of the prosthesis contains a palatal plate with dentures. © 2014 Wiley Periodicals, Inc.

  20. Palateless custom bar supported overdenture: a treatment modality to treat patient with severe gag reflex.

    Science.gov (United States)

    Singh, Kunwarjeet; Gupta, Nidhi

    2012-01-01

    To suggest a custom bar supported overdenture treatment modality for prosthodontic management of patients with severe gag reflex. Some patients have a severe gag reflex and cannot tolerate conventional maxillary complete dentures with maximum palatal coverage and extensions of all borders. The condition further gets complicated in patients suffering from respiratory problems along with severe gag reflex. Severe gagging acts as a barrier to treat such patients with accepted clinical procedures and prevent patients from wearing the prosthesis. By saving some of the remaining natural teeth and fabricating, a horse shoe shape palateless simple tooth or bar supported overdenture can be successfully used for treating such patients. The remaining maxillary right and left canines were prepared with the tapered round end diamond bur to receive copings of custom bar after intentional root canal treatment of same teeth. Impression was made with light body and putty of the polyvinyl siloxane elastomer with double step putty wash technique. Impression was poured with die stone. Wax pattern of copings with bar was fabricated with inlay wax which was invested and casted. After retrieving the bar, it was finished and its fit was evaluated. The coping-bar assembly was finally cemented with the glass ionomer cement. Palateless overdenture was fabricated by conventional technique used for the fabrication of complete denture. Palateless custom bar supported overdenture procedure can be successfully used for the management of patients with severe gag reflex with improved denture retention, stability, chewing efficiency and comfort of the patient.

  1. Leaching from denture base materials in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Lygre, H.; Solheim, E.; Gjerdet, N.R. [School of Medicine, Univ. of Bergen (Norway)

    1995-04-01

    Specimens made from denture base materials were leached in Ringer Solution and in ethanol. The specimens comprised a heat-cured product processed in two different ways and two cold-cured materials. The organic compounds leaching from the specimens to the solutions were separated, identified, and quantified by a combined gas-chromatography and gas-chromatography/mass-spectrometry technique. Additives and degradation products, possibly made by free radical reactions, were released from the denture base materials. In Ringer solution only phthalates could be quantified. In ethanol solvent, biphenyl, dibutyl phthalate, dicyclohexyl phthalate, phenyl benzoate, and phenyl salicylate were quantified. In addition, copper was found in the ethanol solvent from one of the denture base materials. The amount of leachable organic compounds varies among different materials. Processing temperature influences the initial amount of leachable compounds. 36 refs., 7 figs., 1 tab.

  2. Removable partial or complete dentures exposed to beverages and mouthwashes: evaluation of microhardness and roughness

    Directory of Open Access Journals (Sweden)

    Fernanda Alves Feitosa

    Full Text Available AbstractPurposeTo evaluate microhardness and roughness of denture base polymethylmethacrylate resinn exposed to acid beverages and mouthwashes.Material and methodRectangular samples (n=80 were prepared from poly (methyl methacrylate (PMMA. They were divided into 8 groups and had the initial microhardness and Knoop roughness measured. Samples of each group were immersed for 10 min into a test solution (coffee, lemon juice, chlorhexidine gluconate, red wine, cola-based soft drink, vinegar or antiseptic with and without alcohol and after stored in artificial saliva for 23 h and 50 min, completing a period of 24 h. This procedure was performed for 14 consecutive days and after this period the microhardness and surface roughness measurements were made again. Data were statistically analyzed using ANOVA non parametric, Kruskal-Walis and the Dunn´s test for microhardness and the t-Student and ANOVA for roughness.ResultFor microhardness there were found statistically significant differences among the chlorhexidine gluconate solution, antiseptic without alcohol and cola-based soft drink. For roughness was observed that the mean values between the initial period and after immersion in the test products differed statistically in all groups, without difference among groups.ConclusionThe microhardness of poly(methyl methacrylate was affected by continue exposition to chlorhexidine gluconate, antiseptic without alcohol and cola-based soft drink. The roughness of poly(methyl methacrylate is negatively influenced by the exposure to all tested products. It may be concluded that both, microhardness and roughness, were affected by the treatments.

  3. Preoperative concurrent CBDCA chemotherapy and accelerated hyperfractionated radiotherapy for squamous cell carcinoma of the maxillary region

    Energy Technology Data Exchange (ETDEWEB)

    Omura, Ken; Harada, Hiroyuki [Tokyo Medical and Dental Univ. (Japan). Graduate School; Suzuki, Haruhiko; Takeuchi, Yosuke; Hatano, Kazuo; Togawa, Takashi

    2001-11-01

    Between 1994 and 2000, 28 patients with T3/T4 squamus cell carcinoma of the maxillary region (maxillary sinus, 22; maxillary gingiva, 4; maxillary bone, 1; buccal mucosa, 1) had accelerated hyperfractionated radiotherapy combined with simultaneous CBDCA chemotherapy preoperatively, at Chiba Cancer Center Hospital. The protocol consisted of combined therapy with accelerated hyperfractionated irradiation of 1.6 Gy, twice a day, to a total dose of 32.0-51.2 Gy and concurrent intra-arterial or intravenous infusion of CBDCA 20-30 mg/body/day for a cumulative total dose of 270-480 mg. After completion of the preoperative combined therapy, the clinical CR rate was 17.9%, and the good PR{center_dot}CR rate was 32.1%. According to the initial findings and response to the combined therapy, all patients had maxillectomy (subtotal, 3; total, 16; extended, 9) 4 weeks after completion of the preoperative combined therapy. Postoperatively, the complete pathologic response (Ohboshi and Shimozato's classification, grade III and IV) rate was 28.6%. And the actuarial local control rate was 85.7%, with a mean follow-up of 46.2 months. Based on these results, we believe this preoperative therapy with CBDCA chemotherapy and accelerated hyperfractionated radiation is a significant choice as treatment for squamous cell cancer of the maxillary region. (author)

  4. Management of Cleft Maxillary Hypoplasia with Anterior Maxillary Distraction: Our Experience.

    Science.gov (United States)

    Chacko, Tojan; Vinod, Sankar; Mani, Varghese; George, Arun; Sivaprasad, K K

    2014-12-01

    Maxillary hypoplasia is a common developmental problem in cleft lip and palate deformities. Since 1970s these deformities have traditionally been corrected by means of orthognathic surgery. Management of skeletal deformities in the maxillofacial region has been an important challenge for maxillofacial surgeons and orthodontists. Distraction osteogenesis is a surgical technique that uses body's own repairing mechanisms for optimal reconstruction of the tissues. We present four cases of anterior maxillary distraction osteogenesis with tooth borne distraction device-Hyrax, which were analyzed retrospectively for the efficacy of the tooth borne device-Hyrax and skeletal stability of distracted anterior maxillary segment.

  5. Effect of mini-implant-supported mandibular overdentures on electromyographic activity of the masseter muscle during chewing of hard and soft food.

    Science.gov (United States)

    Ashmawy, Tarek Mohy; El Talawy, Dina Bahgat; Shaheen, Nasser Hussein

    2014-09-01

    To objectively evaluate the effect of mini-implant- supported mandibular overdentures on electromyographic activity (EMG) of the masseter muscle during chewing of hard and soft foods. Twelve completely edentulous patients (4 females and 8 males) with maladaptive experience of wearing mandibular dentures received new maxillary and mandibular dentures. After 3 months of adaptation, four mini dental implants (MDIs) were inserted in the interforaminal region of the mandible, and the new mandibular dentures were connected to the implants immediately with O/ring attachments. The activity of masseter muscle (EMG) and the duration of chewing cycle were measured during chewing hard (carrot) and soft (gum) foods. The measurements were made 3 months after wearing each of the following prostheses: the new conventional dentures; and the MDI-retained mandibular overdentures. The EMG of masseter muscle increased and the DC decreased with MDI-retained mandibular overdentures when compared to conventional dentures. Hard food (carrot) was associated with increased EMG and decreased DC when compared to soft food (gum) for both conventional dentures and MDI-retained mandibular overdentures. Mini-implant-supported mandibular overdentures are associated with increased activity of masseter muscle and decreased duration of chewing cycle for both hard and soft foods when compared to conventional dentures.

  6. Removable partial dentures: use of rapid prototyping.

    Science.gov (United States)

    Lima, Julia Magalhaes Costa; Anami, Lilian Costa; Araujo, Rodrigo Maximo; Pavanelli, Carlos A

    2014-10-01

    The CAD/CAM technology associated with rapid prototyping (RP) is already widely used in the fabrication of all-ceramic fixed prostheses and in the biomedical area; however, the use of this technology for the manufacture of metal frames for removable dentures is new. This work reports the results of a literature review conducted on the use of CAD/CAM and RP in the manufacture of removable partial dentures. © 2014 by the American College of Prosthodontists.

  7. Incomplete mobilization of the maxilla resulting in failed maxillary distraction: a case report.

    Science.gov (United States)

    Alkan, Alper; Inal, Samet; Baş, Burcu; Ozer, Mete

    2007-12-01

    Maxillary distraction osteogenesis has become an accepted alternative method in the treatment of patients with severe maxillary hypoplasia in craniofacial syndromes and cleft-related deformities. Insufficient distraction, undesirable soft tissue changes, and occurrence of defective distraction vectors are among the potential complications of intraoral maxillary distraction osteogenesis. A 2-stage procedure combining maxillary advancement by distraction technique with genioplasty and mandibular setback surgery was planned to correct jaw deformities in a 22-year-old patient with severe maxillary retrusion, mandibular prognathism, and excessive lower facial height. In the first stage, osteotomies were performed and maxilla was lightly mobilized after down-fracture. Distractors were placed to the maxilla intraorally. During activation period, the maxilla rotated in a clockwise direction, producing a discrepancy between the planned and the actual vectors. Complete distraction was unsatisfactory and the complication was due to surgical technique. This case report presents the failure of maxillary distraction due to incomplete mobilization of the maxilla. Treatment of the case was achieved by the conventional osteotomy techniques at final operation. The maxilla was successfully advanced to the desired position producing good occlusion and an improved facial profile.

  8. Positional relationship between the maxillary sinus floor and the apex of the maxillary first molar using cone beam computed tomograph

    International Nuclear Information System (INIS)

    Kim, Kyung Hwa; Koh, Kwang Joon

    2008-01-01

    To assess the positional relationship between the maxillary sinus floor and the apex of the maxillary first molar using cone beam computed tomograph (CBCT). CBCTs from 127 subjects were analysed. A total of 134 maxillary first molars were classified according to their vertical and horizontal positional relationship to the maxillary sinus floor and measured according to the distance between the maxillary sinus floor and the maxillary first molar. Type III (The root projected laterally on the sinus cavity but its apex is outside the sinus boundaries) was dominated between 10 and 19 years and type I (The root apex was not in contact with the cortical borders of the sinus) was dominated (P<0.05) between 20 and 72 years on the vertical relationship between the maxillary sinus floor and the apex of the maxillary first molar. The maxillary sinus floor was located more at the apex (78.2%) than at the furcation (21.3%) for the palatal root. The distance from the root apex to the maxillary sinus floor confined to type I was increased according to the ages (P<0.05). Type M (The maxillary sinus floor was located between the buccal and the palatal root) was most common (72.4%) on the horizontal relationship between the maxillary sinus floor and the apex of the maxillary first molar. CBCT can provide highly qualified images for the maxillary sinus floor and the root apex of the maxillary first molar.

  9. Alveolar ridge rehabilitation to increase full denture retention and stability

    Directory of Open Access Journals (Sweden)

    Mefina Kuntjoro

    2010-12-01

    Full Text Available Background: Atrophic mandibular alveolar ridge generally complicates prostetic restoration expecially full denture. Low residual alveolar ridge and basal seat can cause unstable denture, permanent ulcer, pain, neuralgia, and mastication difficulty. Pre-proshetic surgery is needed to improve denture retention and stability. Augmentation is a major surgery to increase vertical height of the atrophic mandible while vestibuloplasty is aimed to increase the denture bearing area. Purpose: The augmentation and vestibuloplasty was aimed to provide stability and retentive denture atrophic mandibular alveolar ridge. Case: A 65 years old woman patient complained about uncomfortable denture. Clinical evaluate showed flat ridge in the anterior mandible, flabby tissue and candidiasis, while residual ridge height was classified into class IV. Case management: Augmentation using autograph was conducted as the mandible vertical height is less than 15 mm. Autograph was used to achieve better bone quantity and quality. Separated alveolar ridge was conducted from left to right canine region and was elevated 0.5 mm from the previous position to get new ridge in the anterior region. The separated alveolar ridge was fixated by using T-plate and ligature wire. Three months after augmentation fixation appliances was removed vestibuloplasty was performed to increase denture bearing area that can make a stable and retentive denture. Conclusion: Augmentation and vestibuloplasty can improve flat ridge to become prominent.Latar belakang: Ridge mandibula yang atrofi pada umumnya mempersulit pembuatan restorasi prostetik terutama gigi tiruan lengkap (GTL. Residual alveolar ridge dan basal seat yang rendah menyebabkan gigi tiruan menjadi tidak stabil, menimbulkan ulser permanen, nyeri, neuralgia, dan kesulitan mengunyah. Tujuan: Augmentasi dan vestibuloplasti pada ridge mandibula yang atrofi dilakukan untuk menciptakan gigi tiruan yang stabil dan retentive. Kasus: Pasien wanita

  10. The oral microbiome of denture wearers is influenced by levels of natural dentition

    NARCIS (Netherlands)

    O'Donnell, L.E.; Robertson, D.; Nile, C.J.; Cross, L.J.; Riggio, M.; Sherriff, A.; Bradshaw, D.; Lambert, M.; Malcolm, J.; Buijs, M.J.; Zaura, E.; Crielaard, W.; Brandt, B.W.; Ramage, G.

    2015-01-01

    Objectives The composition of dental plaque has been well defined, whereas currently there is limited understanding of the composition of denture plaque and how it directly influences denture related stomatitis (DS). The aims of this study were to compare the microbiomes of denture wearers, and to

  11. The effect of number and distribution of unsplinted maxillary implants on the load transfer in implant-retained maxillary overdentures: an in vitro study.

    Science.gov (United States)

    Damghani, Sahar; Masri, Radi; Driscoll, Carl F; Romberg, Elaine

    2012-06-01

    There is little information as to how the number and distribution of implants affect the amount of load transmitted to the palate in implant-retained maxillary overdentures. The purpose of this study was to evaluate the effect of the number and distribution of dental implants on the load transmitted to the palate. Eight implant analogues were placed in a replica of an average sized edentulous maxilla corresponding to the position of canines, first and second premolars, and first molars. The anteroposterior distance between the centers of implants in each quadrant was 8 mm. Fifteen denture bases were fabricated to fit the edentulous maxilla analogue. The denture bases were attached to the oral analogue using 6 different configurations of attachments (6 groups): Either no Locator attachments were used (control group), or the 2 most anterior attachments were attached, or 4 implants were engaged with a distance of 8, 16, or 24 mm between the centers of implants on left and right side, and finally, when all 8 attachments were activated. A force-measuring sensor was used to measure the force transmitted to the palate when a static force of 245 N was applied on the occlusal rims of the denture bases. Data (Newtons) were analyzed using 1-way ANOVA and Tukey's HSD test α=.05). The mean (SD) amount of force measured on the palate when the overdentures were supported by 4 Locator attachments; [49.84 (26.52) at 8 mm spacing], [24.42 (15.05) at 16 mm spacing], [35.66 (22.94) at 24 mm spacing] was significantly lower than when no attachments [90.98 (20.20), control], or when 2 Locator attachments were used [76.07 (27.63)] (Poverdentures were supported by 8 Locator attachments, the force measured on the palate [20.67(16.06) N] was significantly lower than that for the control group (Poverdentures supported by 2 Locator attachments (Poverdentures supported by 4 Locator attachments when the distance between the anterior and posterior implants was 8 mm P=.006). The distribution of

  12. Patients with burning mouth sensations. A clinical investigation of causative factors in a group of "compete denture wearers" Jordanian population.

    Science.gov (United States)

    Mukatash-Nimri, Gadeer Elea; Al-Nimri, Marwan A; Al-Jadeed, Omar G; Al-Zobe, Zaid R; Aburumman, Khuzama K; Masarwa, Nader A

    2017-01-01

    To find out the prevalence of "true" burning mouth syndrome and study the association between patients' spontaneous complaints of burning mouth and systemic conditions in a group of middle age and elderly "denture wearers" patients in Jordan. A group of 129 patients (112 female and 17 male) of "complete denture wearers" subjects aged 40 years and over attended prosthetic clinic at King Hussein Medical Hospital complaining from oral burning, with no oral lesion possibly responsible for the burning sensations were selected. Assessment of oral and general status was done based on questioners, detailed history taking, medical records and extra and intraoral examination. The existed complete dentures retention, stability, jaw relationship and the free way space were evaluated. The current blood test and instrumental protocol for examination of patients with burning mouth complains were performed for each patient. Then those studied patients with burning mouth sensations including "true" burning mouth syndrome have been compared to the controls with regard to the presence of local problem, undermined local, systemic or psychological disease. The diagnosis of "true" burning mouth syndrome was established in (2.3%) of the studied population two females and one male. In most patients (58%) more than one site was affected. Significant positive associations were found between local factors (i.e., wearing complete dentures with unsatisfactory retention or jaw relationship, dry mouth or candidasis) and patients suffering from burning mouth sensation. The results also show that some systemic or psychological disorders were significantly more present among patients with burning mouth symptoms when compared to the control group ( p  burning mouth without mucosal signs should be considered as a manifestation of undermind pathology and/or distress, and the multi-factorial causes of burning mouth syndrome and sensation need to be referred to the suitable specialist for better

  13. Maxillary and mandibular immediately loaded implant-supported interim complete fixed dental prostheses on immediately placed dental implants with a digital approach: A clinical report.

    Science.gov (United States)

    Lewis, Ryan C; Harris, Bryan T; Sarno, Robert; Morton, Dean; Llop, Daniel R; Lin, Wei-Shao

    2015-09-01

    This clinical report describes the treatment of maxillary and mandibular immediate implant placement and immediately loaded implant-supported interim complete fixed dental prostheses with a contemporary digital approach. The virtual diagnostic tooth arrangement eliminated the need for a customized radiographic template, and the diagnostic data collection required for computer-guided surgery (digital diagnostic impressions, digital photographs, and a cone beam-computed tomography [CBCT] scan) was completed in a single visit with improved workflow efficiency. Computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated surgical templates and interim prosthesis templates were made in a dental laboratory to facilitate computer-guided surgery and the immediate loading process. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. [Longitudinal survey and analysis among Chengdu residents on cognition and acceptance of implant dentures].

    Science.gov (United States)

    Zuo, Yanping; Wang, Yongyue; Wang, Luming; Du, Bing

    2014-08-01

    This study aims to survey the cognition and acceptance of implant dentures among Chengdu residents in 2005 and 2013 and to comparatively analyze the differences and influencing factors. A questionnaire was designed for this study. Its main content included basic demographics of respondents (gender, age, cultural level, and income level), cognition level of implant dentures (concept and main characteristics of implant dentures), main concern of respondents regarding implant dentures and medical institutions, and acceptance level of the price of implant dentures, among others. The sampling survey was carried out among Chengdu residents in 2005 and 2013 using the designed questionnaire. The results were then statistically analyzed. Up to 908 valid questionnaires in 2005 and 905 valid questionnaires in 2013 were obtained. The level of cognition of implant dentures was higher in 2013 than in 2005, and the correlation between cognition and cultural level and that between cognition and income level were both positive. However, the correlation between cognition and age was negative. The success rate for implant dentures and medical treatment technology of medical institutions were the factors that the respondents were mainly concerned with. The main methods for disseminating information on implant dentures were the internet, television, newspapers, magazines, and introduction by friends. With the development of the society's economy and the improvement of culture and income level of Chengdu residents, the cognition and acceptance level of implant dentures have gradualy increased. Meanwhile, health education and medical technology still need to be strengthened.

  15. The Use of Implants to Improve Removable Partial Denture Function.

    Science.gov (United States)

    Pimentel, Marcele Jardim; Arréllaga, Juan Pablo; Bacchi, Ataís; Del Bel Cury, Altair A

    2014-12-01

    The oral rehabilitation with conventional removable partial dentures in Kennedy class I patients allows continuous bone resorption, dislodgment of the prosthesis during the mastication caused by the resilience of the mucosa, and rotation of the prosthesis. Thus, the associations of distal implants become an attractive modality of treatment for these patients. This case report presented an association of removable partial dentures, milled crowns and osseointegrated implants to rehabilitate a partial edentulous patient. A removable partial denture associated with implants and metal-ceramic milled crowns can offer excellent esthetics, and will improve function and biomechanics, at a reduced cost.

  16. Maxillary Sinus Floor Augmentation

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Jensen, Janek Dalsgaard

    2017-01-01

    , radiological and histomorphometric outcome as well as complications are presented after maxillary sinus floor augmentation applying the lateral window technique with a graft material, maxillary sinus membrane elevation without a graft material and osteotome-mediated sinus floor elevation with or without...

  17. Assessment of Candida species colonization and denture-related stomatitis in bar- and locator-retained overdentures.

    Science.gov (United States)

    Kilic, Kerem; Koc, Ayse Nedret; Tekinsen, Fatma Filiz; Yildiz, Pinar; Kilic, Duygu; Zararsiz, Gokmen; Kilic, Erdem

    2014-10-01

    The aim of this study was to assess the prevalence of denture-related stomatitis (DRS) in different attachment-retained overdenture wearers and its association with particular colonizing Candida species. Thirty-seven edentulous patients with implant-supported maxillary or mandibular overdentures were enrolled. A full clinical history was obtained, including details of patients' oral hygiene practices and the levels of erythema based on Newton's classification scale. Swabs were taken from the palate and investigated mycologically to identify the yeast colonies. Quantitative and qualitative microbiological assessments were performed, which included recording the total numbers of colonies (cfu), their color, and their morphological characteristics. Significant differences were found in cfu values between the attachment and inner surfaces of locator- and bar-retained overdentures (P overdentures and 38.1% of locator-retained overdentures. DRS developed in all patients using bar-retained overdentures but in only 71.4% of those using locator-retained overdentures. No statistically significant relationship was found between bar and locator attachments according to smoking habit, overnight removal, or plaque and gingival indices (P > .05).

  18. Load transfer characteristics of unilateral distal extension removable partial dentures with polyacetal resin supporting components.

    Science.gov (United States)

    Jiao, T; Chang, T; Caputo, A A

    2009-03-01

    To photoelastically examine load transfer by unilateral distal extension removable partial dentures with supporting and retentive components made of the lower stiffness polyacetal resins. A mandibular photoelastic model, with edentulous space distal to the right second premolar and missing the left first molar, was constructed to determine the load transmission characteristics of a unilateral distal extension base removable partial denture. Individual simulants were used for tooth structure, periodontal ligament, and alveolar bone. Three designs were fabricated: a major connector and clasps made from polyacetal resin, a metal framework as the major connector with polyacetal resin clasp and denture base, and a traditional metal framework I-bar removable partial denture. Simulated posterior bilateral and unilateral occlusal loads were applied to the removable partial dentures. Under bilateral and left side unilateral loading, the highest stress was observed adjacent to the left side posterior teeth with the polyacetal removable partial denture. The lowest stress was seen with the traditional metal framework. Unilateral loads on the right edentulous region produced similar distributed stress under the denture base with all three designs but a somewhat higher intensity with the polyacetal framework. The polyacetal resin removable partial denture concentrated the highest stresses to the abutment and the bone. The traditional metal framework I-bar removable partial denture most equitably distributed force. The hybrid design that combined a metal framework and polyacetal clasp and denture base may be a viable alternative when aesthetics are of primary concern.

  19. Provision of a swing lock denture for a patient with Gorlin Goltz syndrome.

    Science.gov (United States)

    Razaq, I; Durey, K; Nattress, B

    2012-09-01

    Swinglock dentures are used relatively infrequently but in cases of compromised anatomy or where the pattern of tooth loss is unfavourable, they provide a useful removable partial denture design option. The aim of this article is to provide a clear summary of the clinical and technical considerations necessary when providing a Swinglock denture.

  20. Comparison of Fit of Dentures Fabricated by Traditional Techniques Versus CAD/CAM Technology.

    Science.gov (United States)

    McLaughlin, J Bryan; Ramos, Van; Dickinson, Douglas P

    2017-11-14

    To compare the shrinkage of denture bases fabricated by three methods: CAD/CAM, compression molding, and injection molding. The effect of arch form and palate depth was also tested. Nine titanium casts, representing combinations of tapered, ovoid, and square arch forms and shallow, medium, and deep palate depths, were fabricated using electron beam melting (EBM) technology. For each base fabrication method, three poly(vinyl siloxane) impressions were made from each cast, 27 dentures for each method. Compression-molded dentures were fabricated using Lucitone 199 poly methyl methacrylate (PMMA), and injection molded dentures with Ivobase's Hybrid Pink PMMA. For CAD/CAM, denture bases were designed and milled by Avadent using their Light PMMA. To quantify the space between the denture and the master cast, silicone duplicating material was placed in the intaglio of the dentures, the titanium master cast was seated under pressure, and the silicone was then trimmed and recovered. Three silicone measurements per denture were recorded, for a total of 243 measurements. Each silicone measurement was weighed and adjusted to the surface area of the respective arch, giving an average and standard deviation for each denture. Comparison of manufacturing methods showed a statistically significant difference (p = 0.0001). Using a ratio of the means, compression molding had on average 41% to 47% more space than injection molding and CAD/CAM. Comparison of arch/palate forms showed a statistically significant difference (p = 0.023), with shallow palate forms having more space with compression molding. The ovoid shallow form showed CAD/CAM and compression molding had more space than injection molding. Overall, injection molding and CAD/CAM fabrication methods produced equally well-fitting dentures, with both having a better fit than compression molding. Shallow palates appear to be more affected by shrinkage than medium or deep palates. Shallow ovoid arch forms appear to benefit from

  1. Diminished Antimicrobial Peptide and Antifungal Antibiotic Activities against Candida albicans in Denture Adhesive

    Directory of Open Access Journals (Sweden)

    Amber M. Bates

    2017-02-01

    Full Text Available The underlying causes of denture stomatitis may be related to the long-term use of adhesives, which may predispose individuals to oral candidiasis. In this study, we hypothesize that antimicrobial peptides and antifungal antibiotics have diminished anti-Candida activities in denture adhesive. To show this, nine antimicrobial peptides and five antifungal antibiotics with and without 1.0% denture adhesive were incubated with Candida albicans strains ATCC 64124 and HMV4C in radial diffusion assays. In gels with 1.0% adhesive, HNP-1, HBD2, HBD3, IP-10, LL37 (only one strain, histatin 5 (only one strain, lactoferricin B, and SMAP28 showed diminished activity against C. albicans. In gels with 1.0% adhesive, amphotericin B and chlorhexidine dihydrochloride were active against both strains of C. albicans. These results suggest that denture adhesive may inactivate innate immune mediators in the oral cavity increasing the risk of C. albicans infections, but inclusion of antifungal antibiotics to denture adhesive may aid in prevention or treatment of Candida infections and denture stomatitis.

  2. Inhibitory effects of Lactobacillus rhamnosus and Lactobacillus casei on Candida biofilm of denture surface.

    Science.gov (United States)

    Song, Young-Gyun; Lee, Sung-Hoon

    2017-04-01

    Candida albicans biofilm is associated with denture-related stomatitis and oral candidiasis of elderly. Probiotics are beneficial bacteria and have antibacterial activity against pathogenic bacteria. The purpose of this study was to investigate the antifungal activity of various probiotics against C. albicans and the inhibitory effects of probiotics on Candida biofilm on the denture surface. The spent culture media of various probiotics were investigated the antifungal efficacy against C. albicans. Candida biofilm was formed on a denture base resin and was then treated with Lactobacillus rhamnosus and Lactobacillus casei. Also, the biofilms of L. rhamnosus and L. casei were formed and were sequentially treated with C. albicans. Colony-forming units of C. albicans on the denture surface were counted after spreading on agar plate. The denture base resin was treated with the spent culture media for 30days, after which the denture surface roughness was analyzed with an atomic force microscope. L. rhamnosus and L. casei exhibited stronger antifungal activity than other probiotics. The spent culture medium of L. rhamnosus and L. casei exhibited the antifungal activity against blastoconidia and biofilm of C. albicans. L. rhamnosus and L. casei showed the antifungal activity against Candida biofilm, and the biofilm of L. rhamnosus and L. casei inhibited formation of Candida biofilm on denture surface. Neither of the probiotics affected the surface roughness of the denture base resin. L. rhamnosus and L. casei may be the ideal probiotics for the prevention and treatment of denture-related stomatitis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Maxillary Chronic Osteomyelitis Caused by Domestic Violence: A Diagnostic Challenge

    Science.gov (United States)

    Oliveira, Tamyris Inácio; de Carli, Marina Lara; Ribeiro Junior, Noé Vital; Pereira, Alessandro Antônio Costa; Tatakis, Dimitris N.; Hanemann, João Adolfo Costa

    2014-01-01

    Maxillary osteomyelitis is a rare condition defined as inflammation of the bone primarily caused by odontogenic bacteria, with trauma being the second leading cause. The present report documents a rare case of maxillary osteomyelitis in a 38-year-old female who was the victim of domestic violence approximately a year prior to presentation. Intraoral examination revealed a lesion appearing as exposed bony sequestrum, with significant destruction of gingiva and alveolar mucosa in the maxillary right quadrant, accompanied by significant pain, local edema, and continued purulence. Teeth numbers 11, 12, 13, 14, and 15 were mobile, not responsive to percussion, and nonvital. Treatment included antibiotic therapy for seven days followed by total enucleation of the necrotic bone tissue and extraction of the involved teeth. Microscopic findings confirmed the clinical diagnosis of chronic suppurative osteomyelitis. Six months postoperatively, the treated area presented complete healing and there was no sign of recurrence of the lesion. PMID:25610667

  4. Maxillary Chronic Osteomyelitis Caused by Domestic Violence: A Diagnostic Challenge

    Directory of Open Access Journals (Sweden)

    Tamyris Inácio Oliveira

    2014-01-01

    Full Text Available Maxillary osteomyelitis is a rare condition defined as inflammation of the bone primarily caused by odontogenic bacteria, with trauma being the second leading cause. The present report documents a rare case of maxillary osteomyelitis in a 38-year-old female who was the victim of domestic violence approximately a year prior to presentation. Intraoral examination revealed a lesion appearing as exposed bony sequestrum, with significant destruction of gingiva and alveolar mucosa in the maxillary right quadrant, accompanied by significant pain, local edema, and continued purulence. Teeth numbers 11, 12, 13, 14, and 15 were mobile, not responsive to percussion, and nonvital. Treatment included antibiotic therapy for seven days followed by total enucleation of the necrotic bone tissue and extraction of the involved teeth. Microscopic findings confirmed the clinical diagnosis of chronic suppurative osteomyelitis. Six months postoperatively, the treated area presented complete healing and there was no sign of recurrence of the lesion.

  5. Use of transitional implants for immediate loading in mandibular complete dentures- A case report

    Directory of Open Access Journals (Sweden)

    Seema Bhoosreddy

    2009-01-01

    Full Text Available After the placement of implants in areas in which several teeth have been lost, both the clinician and the patient face many difficulties, particularly during healing. If no prosthesis is provided, the patient′s quality of life suffers. If a removable prosthesis is provided for optimum mastication and speech, many complicated adjustments of the denture may become necessary during healing, and the possibility of osseointegration failure increases. It has been reported that for implants to become osseointegrated, they must heal in the absence of functional loads for 4 to 6 months. To address the need for undisturbed healing and patient demand for uninterrupted immediate function and esthetics, the transitional implant system has been developed. This case report describes the use of transitional implants to support a removable mandibular overdenture. The transitional implant system is a sound and economical method of immediate patient restoration that allows for the protected healing of submerged implants.

  6. [Influence of attachment type on stress distribution of implant-supported removable partial dentures].

    Science.gov (United States)

    Yang, Xue; Rong, Qi-guo; Yang, Ya-dong

    2015-02-18

    To compare influences of different retention attachments on stress among supporting structures. By 3-dimensional laser scanner and reverse engineering computer aided design (CAD) software, a basic partially edentulous digital model with mandibular premolar and molar missing was established. Implant attachment and removable partial dentures (RPD) were added into the basic model to build three kinds of models: RPD only, RPD + implant + Locator attachment, and RPD + implant + Magfit attachment. Vertical and inclined loads were put on artificial teeth unilaterally. By means of 3-dimensional finite element analysis, the stress distribution and displacement of the main supportive structures were compared. A complete 3-dimensional finite element model was established, which contained tooth structure, and periodontal structures. The displacement of the denture was smaller in Locator (9.38 μm vertically, 45.48 μm obliquely) and Magfit models (9.54 μm vertically, 39.45 μm obliquely) compared with non-implant RPD model (95.27 μm vertically, 155.70 μm obliquely). Compared with the two different attachments, cortical bone stress value was higher in Locator model (Locator model 10.850 MPa vertically, 43.760 MPa obliquely; Magfit model 7.100 MPa vertically, 19.260 MPa obliquely).The stress value of abutment periodontal ligamentin Magfit model (0.420 MPa vertically) was lower than that in Locator model (0.520 MPa vertically). The existence of implant could reduce maximum von Mises value of each supportive structure when Kennedy I partially edentulous mandible was restored. Comparing the structure of Magfit and Locator attachment, the contact of Magfit attachment was rigid, while Locator was resilient. Locator attachment could improve stability of the denture dramatically. Locator had stronger effect on defending horizontal movement of the denture.

  7. The Palatal Window for Treating an Incompletely Augmented Maxillary Sinus.

    Science.gov (United States)

    Florio, Salvatore; Suzuki, Takanori; Cho, Sang-Choon

    2017-04-01

    Maxillary sinus augmentation through a lateral window is reported as one of the most predictable bone augmentation procedures before implant placement. The elevation of the membrane represents a delicate and crucial step that allows the creation of the space for the bone graft material. If the elevation is not completed, the regenerated bone might be inadequate for the implant placement. In this case, a new intervention will be necessary to complete the bone augmentation. Reaccessing from a lateral window, however, would be challenging due to thickness of the buccal boney wall because of the first grafting procedure; therefore, a different approach has to be used. The aim of this case report is to present the palatal window technique for treating incompletely augmented maxillary sinus. The detailed step-by-step diagnostic and surgical procedures are described, and the advantages and limitations of the technique are discussed through a review of the literature.

  8. Silver distribution and release from an antimicrobial denture base resin containing silver colloidal nanoparticles.

    Science.gov (United States)

    Monteiro, Douglas Roberto; Gorup, Luiz Fernando; Takamiya, Aline Satie; de Camargo, Emerson Rodrigues; Filho, Adhemar Colla Ruvolo; Barbosa, Debora Barros

    2012-01-01

    The aim of this study was to evaluate a denture base resin containing silver colloidal nanoparticles through morphological analysis to check the distribution and dispersion of these particles in the polymer and by testing the silver release in deionized water at different time periods. A Lucitone 550 denture resin was used, and silver nanoparticles were synthesized by reduction of silver nitrate with sodium citrate. The acrylic resin was prepared in accordance with the manufacturers' instructions, and silver nanoparticle suspension was added to the acrylic resin monomer in different concentrations (0.05, 0.5, and 5 vol% silver colloidal). Controls devoid of silver nanoparticles were included. The specimens were stored in deionized water at 37°C for 7, 15, 30, 60, and 120 days, and each solution was analyzed using atomic absorption spectroscopy. Silver was not detected in deionized water regardless of the silver nanoparticles added to the resin and of the storage period. Micrographs showed that with lower concentrations, the distribution of silver nanoparticles was reduced, whereas their dispersion was improved in the polymer. Moreover, after 120 days of storage, nanoparticles were mainly located on the surface of the nanocomposite specimens. Incorporation of silver nanoparticles in the acrylic resin was evidenced. Moreover, silver was not detected by the detection limit of the atomic absorption spectrophotometer used in this study, even after 120 days of storage in deionized water. Silver nanoparticles are incorporated in the PMMA denture resin to attain an effective antimicrobial material to help control common infections involving oral mucosal tissues in complete denture wearers. © 2011 by the American College of Prosthodontists.

  9. Vector alignment in maxillary distraction osteogenesis.

    Science.gov (United States)

    Uckan, Sina; Arman, Ayca; Bayram, Burak; Celik, Erkan

    2006-09-01

    Maxillary distraction osteogenesis is an alternative treatment of cleft patients with severe maxillary hypoplasia. The aim of this paper is to present the combined surgical/orthodontic treatment of a cleft lip and palate patient and to evaluate the maxillary distraction procedure and the distraction vector in high Le Fort I osteotomy.

  10. Adjustable selective maxillary expansion combined with maxillomandibular surgery: A case report.

    Science.gov (United States)

    Leyder, Patrick; Altounian, Gérard; Chardain, Jacques; Quilichini, Julien

    2015-09-01

    Surgically assisted rapid maxillary expansion (SARME) is usually considered the gold standard for maxillary transverse expansion in adults. However, a second surgical procedure is needed in cases of associated sagittal or vertical discrepancies. We describe the use of two new innovative devices for the correction of discrepancies in all dimensions during a single surgical procedure, thus reducing treatment duration. We report the case of a 21-year-old female patient, referred to our department for skeletal Class III malocclusion associated with right-side laterognathism and transverse maxillary deficiency. The patient underwent one-stage surgery, using sliding osteosynthesis plates and an adjustable bone-borne distractor. Pre-surgical orthodontics consisted in leveling and aligning the mandibular arch; maxillary leveling was initiated 3 months before surgery. Postoperative palatal distraction combined with orthodontic finishing enabled complete correction of dental and bony discrepancies after 3 months. In our experience, treatment of transverse, sagittal and vertical discrepancies has been possible in a single surgical procedure, using two innovative techniques: sliding osteosynthesis and an adjustable bone distractor. Two years post-surgery, the correction is stable in all dimensions. Copyright © 2015. Published by Elsevier Masson SAS.

  11. Orthopantomographic study of the maxillary sinus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Joo; Yu, Dong Su [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1971-11-15

    The author has observed the orthopantomograms of the maxillary sinus which were taken by special exposure method to study mesiodistal dimension, shape, symmetrical relationship, bony septum of the maxillary sinus and relationship between upper lst molar and the maxillary sinus, that were selected 56 cases of 23 to 27 years old male, who have good systemic conditions and no missing teeth on upper posterior molar in normal occlusion, and obtained following conclusions: 1. Mesiodistal dimensions of the maxillary sinus are shown as follows; The mean of left dimension is 50.94 {+-} 8.34 mm and of right dimension is 49.50 {+-} 9.87 mm. 2. To the shape of the maxillary sinus, V or U shape are 33 cases(29.5%) and W shape are 77 cases (70.5%). 3. In the ralationship between upper lst molar and floor of the maxllary sinus, superimposition are 62 cases (55.36%) a nd approach are 50 cases (44.64%). 4. In the right and left symmetrical relationship of the maxillary sinus, symmetry are 37 cases (66.07%) and asymmetry are 19 cases (33.93%). 5. The bony septums in the maxillary sinuses revealed that presence of bony septums are 29 cases (25.8%) and absence ar e 83 cases (74.11%).

  12. Connection of functional quality of partial removable dentures and the degree of patients' phonetic adaptation.

    Science.gov (United States)

    Artjomenko, Victoria; Vidzis, Aldis; Zigurs, Guntis

    2015-01-01

    Phonetic adaptation is a complex biological phenomenon with a highly individual course, depending on the patient's motivation to use prosthesis, on the functional quality of removable dentures. The aim of the study was to estimate phonetic adaptation in patients with partial dentures, connecting it to alteration in speech quality and dentures functional value. We examined some peculiarities of phonetic adaptation in 50 patients with removable dentures (50 patients with natural dentition were invited for the control group). The standardized evaluation protocols (12 speech quality determining parameters) were developed separately for Latvian and Russian native speakers. 500 speech video samples were recorded and analysed according to pre-established guidelines. The connection of speech quality and the functional quality of the dentures was assessed. Statistical analysis was performed using SPSS 20.0. P values equal to or less than 0.05 were considered to be statistically significant. In patients with appropriate functional quality of removable dentures distorted speech production was detected in 25% (pk=0.008) cases and in patients with inappropriate functional quality of the prosthesis - in 40% (pkdentures functional value were satisfied with their speech performance in 96% (pk=0.674), in the group with inappropriate dentures functional value only 59% (premovable dentures depends on the patient's individual adaptation capacity, prosthetic design and functional value. Thus statistically significant correlation between removable partial dentures functional value, duration of usage and the degree of patients' phonetic adaptation (p<0.001) may be considered to be confirmed.

  13. Removable Partial Denture Supported by Implants with Prefabricated Telescopic Abutments - A Case Report

    Science.gov (United States)

    Sehgal, Komal

    2014-01-01

    Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy—biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs. PMID:25121066

  14. Removable partial denture supported by implants with prefabricated telescopic abutments - a case report.

    Science.gov (United States)

    Kumar, Lalit; Sehgal, Komal

    2014-06-01

    Implants have been designed to rehabilitate edentulous patients with fixed prosthesis or implant supported overdentures. Implant-supported single crowns and fixed partial dentures have become successful treatment alternatives to removable and fixed partial dentures. However, it is common to have clinical situations which make it impossible to use conventional as well as implant supported fixed partial dentures. The implant supported removable partial dentures can be a treatment modality that offers the multitude of benefits of implant-based therapy-biologic, biomechanical, social, and psychological to such patients. The aim of this article is to present a case report describing the fabrication and advantages of removable partial denture supported by teeth and implants for a patient with long edentulous span. The patient was satisfied with his dentures in terms of function and aesthetics. Regular follow-up visits over a period of three years revealed that the periodontal condition of remaining natural dentition and peri-implant conditions were stable. There was no evidence of excessive residual ridge resorption or mobility of the teeth, nor were any visible changes in the bone levels of the natural teeth or implants noted on radiographs.

  15. Keratocystic odontogenic tumor with impacted maxillary third molar involving the right maxillary antrum:An unusual case report

    Directory of Open Access Journals (Sweden)

    Abhishek Gupta

    2011-01-01

    Full Text Available The odontogenic keratocyst (OKC, first described by Phillipsen in 1956, has metamorphosized as a keratocystic odontogenic tumor (KCOT as reported in WHO classification of head and neck tumors in 2005. KCOT is a benign intraosseous neoplasm of the jaw and its occurrence in maxilla is unusual and its appearance in maxillary antrum along with maxillary impacted third molar is very uncommon. This article reports a case of KCOT associated with impacted maxillary third molar in right maxillary antrum and describes its rare site of occurrence.

  16. Cytotoxicity of four denture adhesives on human gingival fibroblast cells.

    Science.gov (United States)

    Lee, Yoon; Ahn, Jin-Soo; Yi, Young-Ah; Chung, Shin-Hye; Yoo, Yeon-Jee; Ju, Sung-Won; Hwang, Ji-Yun; Seo, Deog-Gyu

    2015-02-01

    The purpose of this study was to compare the cytotoxicity of four denture adhesives on human gingival fibroblast cells. Immortalized human gingival fibroblasts were cultured with one of four different denture adhesives, Polident, Protefix, Staydent or Denfix-A, which was placed in insert dishes (10% w/v concentration) for 48 h. The MTT [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] assay and flow cytometric apoptosis assay were used to evaluate cell viability and apoptosis rates. The fibroblasts were also examined under a scanning electron microscope. The MTT assay showed that all denture adhesives resulted in a significantly lower cell viability compared to the control cells propagated in normal culture medium (p 0.05). Staydent showed the highest apoptosis rate. Scanning electron microscopy showed that the cells of the Staydent group underwent cytoplasmic membrane shrinkage, with cell free areas containing residual fragments of the membrane of dead cells. The four denture adhesives evaluated in this study imparted cytotoxic effects on human gingival fibroblast cells. Staydent showed the highest toxicity.

  17. Patient's Satisfaction with Removable Partial Dentures: A Retrospective Case Series.

    Science.gov (United States)

    Shala, Kujtim Sh; Dula, Linda J; Pustina-Krasniqi, Teuta; Bicaj, Teuta; Ahmedi, Enis F; Lila-Krasniqi, Zana; Tmava-Dragusha, Arlinda

    2016-01-01

    This retrospective clinical study aimed to assess patient's satisfaction with removable partial dentures (RPDs), as retention, chewing ability, aesthetics during the observation period. A total of 63 patients with RPDs, participated in this study. The following data was collected: Kennedy classification, denture design, denture support, satisfaction and success of RPD. The results showed that 73.6% of patients were wearing RPD for the first time and were finally satisfied. According to the denture support of RPDs, clasp-retained quadrangular RPDs were 100% effective, followed by triangular dental support 81% and linear dental support 47.7%. Comparison of RPDs with attachment with RPDs with claps assessed through Fisher exact test, confirmed statistically significant difference (P=0.008), despite retention; however, chewing ability and aesthetics showed no statistically significant difference with X 2 test on patient's satisfaction with RPD with or without attachment. Patients often would prefer not showing the anterior buccal clasps of RPD, therefore are generally satisfied more with RPD with attachment based on level of retention, chewing ability and aesthetics.

  18. Effect of biofilm formation, and biocorrosion on denture base fractures.

    Science.gov (United States)

    Sahin, Cem; Ergin, Alper; Ayyildiz, Simel; Cosgun, Erdal; Uzun, Gulay

    2013-05-01

    The aim of this study was to investigate the destructive effects of biofilm formation and/or biocorrosive activity of 6 different oral microorganisms. Three different heat polymerized acrylic resins (Ivocap Plus, Lucitone 550, QC 20) were used to prepare three different types of samples. Type "A" samples with "V" type notch was used to measure the fracture strength, "B" type to evaluate the surfaces with scanning electron microscopy and "C" type for quantitative biofilm assay. Development and calculation of biofilm covered surfaces on denture base materials were accomplished by SEM and quantitative biofilm assay. According to normality assumptions ANOVA or Kruskal-Wallis was selected for statistical analysis (α=0.05). Significant differences were obtained among the adhesion potential of 6 different microorganisms and there were significant differences among their adhesion onto 3 different denture base materials. Compared to the control groups after contamination with the microorganisms, the three point bending test values of denture base materials decreased significantly (P.05). All the tested microorganisms had destructive effect over the structure and composition of the denture base materials.

  19. Investigation of the implant-supported overdentures in completely edentulous mandibles

    Directory of Open Access Journals (Sweden)

    Yu-Hwa Pan

    2015-12-01

    Conclusion: Our results indicate that implant-supported overdentures provide a reliable and effective alternative to conventional complete mandibular dentures. Overdentures with Hader bars and bilateral, cast ERA attachments resulted in fewer prosthetic complications.

  20. Denture identification using unique identification authority of India barcode

    OpenAIRE

    Sudhindra Mahoorkar; Anoop Jain

    2013-01-01

    Over the years, various denture marking systems have been reported in the literature for personal identification. They have been broadly divided into surface marking and inclusion methods. In this technique, patient's unique identification number and barcode printed in the patient's Aadhaar card issued by Unique Identification Authority of India (UIDAI) are used as denture markers. This article describes a simple, quick, and economical method for identification of individual.

  1. Denture identification using unique identification authority of India barcode.

    Science.gov (United States)

    Mahoorkar, Sudhindra; Jain, Anoop

    2013-01-01

    Over the years, various denture marking systems have been reported in the literature for personal identification. They have been broadly divided into surface marking and inclusion methods. In this technique, patient's unique identification number and barcode printed in the patient's Aadhaar card issued by Unique Identification Authority of India (UIDAI) are used as denture markers. This article describes a simple, quick, and economical method for identification of individual.

  2. Telescopic Partial Dentures-Concealed Technology.

    Science.gov (United States)

    Bhagat, Tushar Vitthalrao; Walke, Ashwini Nareshchandra

    2015-09-01

    The ideal goal of good dentist is to restore the missing part of oral structure, phonetics, his look and the most important is restored the normal health of the patient, which is hampered due to less or insufficient intake of food. Removable partial denture (RPD) treatment option is considered as a notion, which precludes the inevitability of "floating plastic" in edentulous mouth, that many times fail to fulfill the above essential of the patients. In modern dentistry, though the dental implants or fixed partial denture is the better options, but they have certain limitations. However, overdentures and particularly telescopic denture is the overlooked technology in dentistry that would be a boon for such needy patients. Telescopic denture is especially indicated in the distal edentulous area with minimum two teeth bilaterally present with a good amount of periodontal support. This treatment modality is sort of preventive prosthodontics remedy, which in a conservative manner preserve the remaining teeth and helps in conservation of alveolar bone ultimately. There are two tenets related to this option, one is constant conservation edentulous ridge around the retained tooth and the most important is the endless existence of periodontal sensory action that directs and monitor gnathodynamic task. In this option the primary coping or inner coping are cemented on the prepared tooth, and a similar removable outer or inner telescopic crown placed tightly by using a mechanism of tenso-friction, this is firmly attached to a removable RPD in place without moving or rocking of the prosthesis, which is the common compliant of almost all patients of RPD. Copings are also protecting the abutment from tooth decay and also offers stabilization and maintaining of the outer crown. The outer crown engages the inner coping and gives as an anchor for the remainder of the dentition. This work is the review of telescopic prosthesis which is well supported by the case discussion, and

  3. Forças de mordida relacionadas a próteses parciais removíveis inferiores Biting forces related to partially removable mandibular dentures

    Directory of Open Access Journals (Sweden)

    Eduardo Piza PELLIZZER

    1998-10-01

    Full Text Available A pesquisa teve como objetivo determinar as forças de mordida de 73 indivíduos, por meio de um gnatodinamômetro. Os pacientes eram portadores de próteses parciais removíveis inferiores classes I, II ou III. A arcada antagonista era prótese, parcial removível ou fixa, ou total. Os resultados permitiram concluir que: as selas de extremidade livre, principalmente em suas posições extremas, conduziram a forças de mordida muito baixas; o envolvimento de prótese total, também, conduziu a forças de mordida baixas; o sexo masculino alcançou valores maiores que o feminino; com prótese parcial removível classe III, os dentes naturais molares e pré-molares desenvolveram valores maiores do que com classes I e II.The purpose of this study was to determine the biting forces of individuals wearing classes I, II or III partially removable mandibular dentures. Upper jaws presented fixed bridges, classes I, II or III partially removable dentures, or complete dentures. Measurements of biting forces were obtained by a gnathodynamometer. The conclusions were: classes I and II presented low biting forces, specially far from the last abutment tooth; when the opposite arcade was a complete denture, biting forces were low; males presented higher biting forces than females; natural molars and bicuspids presented higher biting forces with class III than with classes I or II.

  4. Occlusal plane location in edentulous patients: a review.

    Science.gov (United States)

    Shetty, Sanath; Zargar, Nazia Majeed; Shenoy, Kamalakanth; Rekha, V

    2013-09-01

    Occlusal plane orientation is an important factor in the construction of a complete denture. Occlusal plane could be oriented using landmarks in the mandibular arch as well as in the maxillary arch. In the mandibular arch there are few landmarks which could be used to orient the occlusal plane like the retromolar pad, corner of the lips (lower lip length) whereas the maxillary arch has a number of landmarks, of which the ala-tragal line is the most commonly used and the same being the most controversial. In the following article different landmarks and its accuracy for orientating the occlusal plane in an edentulous subject as studied by various authors has been discussed.

  5. Correlation between factors associated with the removable partial dentures use and Candida spp. in saliva.

    Science.gov (United States)

    Gusmão, João Milton Rocha; Ferreira dos Santos, Silvana Soleo; Neisser, Maximiliano Piero; Jorge, Antônio Olavo Cardoso; Faria, Ms Ivan

    2011-12-01

    To correlate the presence and number of Candida spp. in the saliva of wearers of removable partial dentures retained with precision attachments with the proportion of metal/acrylic resin present in the dentures. Saliva samples from 40 removable partial denture wearers (test) and one paired sample of individuals, non-wearers of any type of removable denture (control) were collected, seeded, and the colony forming units of Candida counted and identified. The metal/acrylic resin proportion of each denture was quantified, using silicone plates pressed over each denture. Candida spp. was found in the saliva of 80% of the individuals in the test group and 65% of the control, with C. albicans being the most prevalent species. The test group presented with the highest number of colony forming units of Candida per ml of saliva, and there was weak correlation between this number and the metal and resin area of the denture (Pearson's coefficient of correlation). Greater prevalence and a higher number of colony forming units of Candida per ml of saliva occurred in removable partial denture wearers (p = 0.04) with a weak positive correlation between the metal and resin area and the number of colony forming units of Candida per ml of saliva. However, this correlation was more significant for the area of resin. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  6. Use of Candida-specific chicken egg yolk antibodies to inhibit the adhering of Candida to denture base materials: prevention of denture stomatitis.

    Science.gov (United States)

    Kamikawa, Yoshiaki; Fujisaki, Junichi; Nagayama, Tomohiro; Kawasaki, Kiyotsugu; Hirabayashi, Daisuke; Hamada, Tomofumi; Sakamoto, Ryoich; Mukai, Hiroshi; Sugihara, Kazumasa

    2016-09-01

    Polyclonal anti-Candida chicken egg yolk antibodies (anti-IgY) were used to investigate the prevention of adherence of Candida species to denture base material in vitro. Candida is a potential virulence factor that can cause systemic infection and even death in immunocompromised individuals. Because long-term antifungal treatment may lead to the emergence of drug-resistant strains, it is necessary to develop novel preventive measures and treatments for candidiasis. Three types of chicken egg yolk antibodies were used in this study: non-specific antibody (control IgY), Candida albicans-specific antibody (anti-C.a.IgY) and Candida glabrata-specific antibody (anti-C.g.IgY). A mixture of different dilutions of each antibody with a suspension of Candida species and denture base material was incubated for 3 h, and then the colony-forming units of Candida on the denture base material were counted. Compared with control IgY, anti-C.a.IgY and anti-C.g.IgY significantly inhibited the adherence of C. albicans, but anti-C.a.IgY tended to be more potent than anti-C.g.IgY. The adherence of C. glabrata was also inhibited significantly by anti-C.a.IgY and anti-C.g.IgY with almost equivalent potency, indicating that their actions against C. glabrata were comparable. This study revealed the inhibitory effects of anti-C.a.IgY and anti-C.g.IgY against the adherence of C. albicans and C. glabrata to denture base material. This finding indicates the possibility of a beneficial effect of IgYs for the prevention of denture stomatitis and candidiasis in clinical settings. © 2014 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  7. Maxillary Anterior Segmental Distraction Osteogenesis to Correct Maxillary Deficiencies in a Patient With Cleft Lip and Palate.

    Science.gov (United States)

    Kageyama-Iwata, Asuka; Haraguchi, Seiji; Iida, Seiji; Aikawa, Tomonao; Yamashiro, Takashi

    2017-07-01

    This report describes a case of successful orthodontic treatment using maxillary anterior segmental distraction osteogenesis with an internal maxillary distractor and bilateral sagittal split ramus osteotomy in a girl with cleft lip and palate. A 16-year-old girl with unilateral cleft lip and palate exhibited midface retrusion because of growth inhibition of the maxillary complex and mandibular excess. After the presurgical orthodontic treatment, 6.0-mm advancement of the maxillary anterior segment and 4.0-mm set back of the mandible were performed. After a retention period, the patient's midface convexity was greatly improved and the velopharyngeal competence was preserved without relapse.

  8. Evaluation of articulation of Turkish phonemes after removable partial denture application

    Directory of Open Access Journals (Sweden)

    Özbeki Murat

    2003-01-01

    Full Text Available In this study, the adaptation of patients to removable partial dentures was evaluated related to articulation of Turkish phonemes. Articulation of /t,d,n,l,r/, /g,k/, /b,p,m/ and /s,z,Õ,v,f,y,j,h,c/ phonemes were evaluated by three speech pathologists, on records taken from 15 patients before the insertion of a removable partial denture, just after insertion, and one week later. The test consisted of evaluation of phoneme articulation of independent syllables in terms of distortion, omission, substitution, mass effect, hypernasality and hyponasality. Data were evaluated with Cochrane Q, McNemar and Kruskal-Wallis tests. The results showed that for some phonemes, problems in articulation occurred after the insertion of a removable partial denture while for others a significant amelioration was observed after the insertion of a removable partial denture. In general, problems in articulation of evaluated phonemes were resolved after one week of use.

  9. A comparative finite elemental analysis of glass abutment supported and unsupported cantilever fixed partial denture.

    Science.gov (United States)

    Ramakrishaniah, Ravikumar; Al Kheraif, Abdulaziz A; Elsharawy, Mohamed A; Alsaleh, Ayman K; Ismail Mohamed, Karem M; Rehman, Ihtesham Ur

    2015-05-01

    The purpose of this study was to investigate and compare the load distribution and displacement of cantilever prostheses with and without glass abutment by three dimensional finite element analysis. Micro-computed tomography was used to study the relationship between the glass abutment and the ridge. The external surface of the maxilla was scanned, and a simplified finite element model was constructed. The ZX-27 glass abutment and the maxillary first and second premolars were created and modified. The solid model of the three-unit cantilever fixed partial denture was scanned, and the fitting surface was modified with reference to the created abutments using the 3D CAD system. The finite element analysis was completed in ANSYS. The fit and total gap volume between the glass abutment and dental model were determined by Skyscan 1173 high-energy spiral micro-CT scan. The results of the finite element analysis in this study showed that the cantilever prosthesis supported by the glass abutment demonstrated significantly less stress on the terminal abutment and overall deformation of the prosthesis under vertical and oblique load. Micro-computed tomography determined a gap volume of 6.74162 mm(3). By contacting the mucosa, glass abutments transfer some amount of masticatory load to the residual alveolar ridge, thereby preventing damage to the periodontal microstructures of the terminal abutment. The passive contact of the glass abutment with the mucosa not only preserves the health of the mucosa covering the ridge but also permits easy cleaning. It is possible to increase the success rate of cantilever FPDs by supporting the cantilevered pontic with glass abutments. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  10. Patient satisfaction and dissatisfaction with mandibular two-implant overdentures using different attachment systems: 5-year outcomes.

    Science.gov (United States)

    Al-Zubeidi, Mohammed I; Alsabeeha, Nabeel H M; Thomson, W Murray; Payne, Alan G T

    2012-10-01

    Different attachment systems for mandibular two-implant overdentures could influence levels of patient satisfaction. Positive consensus of the majority of patients being satisfied does not preclude the possibility of dissatisfaction for some. To evaluate patient satisfaction and dissatisfaction before and after 5 years of wearing mandibular two implant overdentures using different attachment systems ; to determine the prognostic relevance of pretreatment complete denture complaints to treatment outcomes. A total of 106 edentulous participants enrolled in a clinical trial completed a preliminary self-report inventory of their original complete denture complaints.New complete maxillary dentures and mandibular two-implant overdentures were provided to each participant using one of six different attachment systems. Patient satisfaction was determined at pretreatment; at baseline with mandibular two-implant overdenture insertion; and then annually for 5 years, using visual analogue and Likert-type scales. Patient satisfaction with mandibular two-implant overdentures showed significant changes pre- to posttreatment(baseline) in all domains, but these were significant immediately and maintained without further significance for 5 years, other than pain with the overdenture. After 5 years, no significant differences were observed with all the attachment systems. Highly significant differences were found with some social and psychological aspects by the fifth year compared to baseline. Diagnostic and prognostic indicators from a pretreatment inventory identified 12 participants (13.5%) who were dissatisfied. These indicators revealed a maladaptive predisposition to mandibular two-implant overdentures. The provision of mandibular two-implant overdentures will, in the majority of patients, significantly enhance levels of patient satisfaction for 5 years, as compared to complete mandibular dentures, regardless of the attachment system. Careful evaluation of pretreatment

  11. Prosthodontic Management of Xerostomic Patient: A Technical Modification

    Directory of Open Access Journals (Sweden)

    Haraswarupa Gurkar

    2016-01-01

    Full Text Available Xerostomia is often a contributing factor in both minor and serious health problems. It can affect nutrition and dental as well as psychological health. Common problems faced by such patients are glossitis, mucositis, angular cheilitis, dysgeusia, and difficulty in chewing and swallowing. One of the major problems associated with xerostomic patients is the poor tolerance and retention of removable dental prostheses because of thin dry atrophic mucosa and lack of a saliva film. This paper describes a new technique of incorporating a salivary reservoir in the maxillary complete denture. The salivary reservoir fabricated by this technique provided good lubrication of the oral tissues and was easily cleansed by the wearer and was fabricated from routine denture materials.

  12. Comparison of three-implant-supported fixed dentures and two-implant-retained overdentures in the edentulous mandible: a pilot study of treatment efficacy and patient satisfaction.

    Science.gov (United States)

    De Kok, Ingeborg J; Chang, Kuang-Han; Lu, Tsui-Shan; Cooper, Lyndon F

    2011-01-01

    The mandibular two-implant overdenture has been shown to be a highly successful treatment. However, overdenture patients who desire a fixed prosthesis may not be satisfied with a removable overdenture. This prospective study sought to compare prosthetic outcomes, patient satisfaction, and survival rates of implants between two-implant-supported overdentures (IODs) and three-implant-supported fixed dentures (ISFDs). Twenty completely edentulous patients were randomly and equally assigned to two groups. New conventional complete dentures were made, and the mandibular denture was used as a surgical guide during implant placement. Implants were placed in one stage, followed by a mandibular denture soft reline (provisional loading). Ball attachments were inserted at 8 weeks, and ISFDs were delivered at 16 weeks. IODs were connected to the attachments at 8 weeks, using each patients's existing denture. The definitive ISFDs were fabricated using computer-aided design/computer-assisted manufacture milled titanium frameworks and acrylic resin base and teeth. Patient satisfaction and panoramic radiographs were investigated at 6 and 12 months. Both treatments had significant and positive effects on patient satisfaction and quality of life. None of the 50 implants placed had failed at 12 months of follow-up; therefore, the implant survival rate was 100%. Prosthetic complications were generally rare and easily manageable. Both the treatment modalities-the ISFD supported by three implants and the IOD supported by two implants-significantly and similarly improved patient satisfaction and oral health-related quality of life, and prosthetic complications were relatively rare for both treatments. Three implants can be used to support a mandibular fixed prosthesis; however, a longer observation period is needed to validate this treatment modality.

  13. A Radiologic Study of the Relationship of the Maxillary Sinus Floor and Apex of the Maxillary Molar

    International Nuclear Information System (INIS)

    Yoon, Hae Rym; Park, Chang Seo

    1998-01-01

    In this study, radiographic evaluation was made using panoramic radiography and cross-sectional tomography of SCANORA in male and female adults in their 20 s on the relationship between the maxillary sinus floor and the apex of the maxillary molar, to test the accuracy and effectiveness of the cross-sectional tomography, and to use this information in the assessment of preop, and postop, root canal treatment, apical surgery, extraction and implantology. Forty-one adults with an average age of 24.4 years were studied panoramic radiography and cross-sectional tomography. In panoramic view and cross-sectional view, the position of the apices of maxillary molars were classified as separated, contacted, or protruded type; the general shape of the maxillary sinus floor was evaluated horizontally and vertically from cross-sectional tomography. The accuracy of each radiography was tested using maxilla from 5 fresh cadavers from the Anatomy Lab at Yonsei University Dental College, and panoramic view and cross-sectional tomography were taken in the same condition as with the patients. The results were as follows ; 1. Panoramic view and cross-sectional view were taken in the maxilla specimen, and the actual distance between the maxillary sinus floor and the tooth apices were measured in the specimen; the median values of the distance from the tooth apices to the maxillary sinus floor in the panoramic view, cross-sectional view and in the accrual maxilla specimen were 2.83 mm, 4.51 mm, and 4.15 mm, respectively. In the cross-sectional view, the measured distance was close to the actual distance but in the panoramic view, the measured distance was far from the actual distance. 2. When the results of the panoramic view and cross-sectional view were compared, 40.5% of the results agreed with each other in the two radiographic methods and buccal roots of the 2nd molar were the closest to the maxillary sinus floor in the cross-sectional tomography.3. In cross-sectional view, when

  14. Factors influencing the provision of removable partial dentures by dentists in Ireland.

    Science.gov (United States)

    Allen, Finbarr

    2010-01-01

    Factors influencing clinical treatment of partially dentate patients are varied, and there is a need to identify factors influencing success in the provision of removable partial dentures. The aim of this study was to assess the attitudes of general dental practitioners (GDPs) in Ireland towards tooth replacement and use of RPDs, in partially dentate older adults. The sample frame was the Register of Dentists in Ireland; data were also collected from a sample of dentists practising under NHS regulations in Northern Ireland. Validated questionnaires were sent to all dentists on the Register of Dentists in the Republic of Ireland, and dentists working under NHS regulations registered with the Central Services Agency in Northern Ireland. Content of the questionnaire included details of the dentist themselves, their dental practice and the profile of partial denture provision. They were also asked to give their views on factors influencing the success or failure of an RPD, the process of providing RPDs and their attitudes to RPD provision. A total of 1,143 responses were received, a response rate of 45%. A mean number of 61 RPDs per annum were provided, with 75% of dentures provided being acrylic based. Respondents indicate their belief that cobalt-chromium based dentures had a longer prognosis than acrylic dentures, but less than half (46%) claim to design the frameworks themselves. Patients' attitudes are considered influential in the success of RPD provision, and their influence on appearance is considered the most important factor influencing success. The most important factors influencing failure are: the patient not requesting a denture; an RPD restoring unbounded saddles; and, lower RPDs. Although considered important, approximately 60% of the sample do not routinely organise follow-up appointments for patients provided with RPDs. The fee structures in the DTSS and DTBS are considered a barrier to quality in the provision of partial dentures.

  15. Factors influencing the provision of removable partial dentures by dentists in Ireland.

    LENUS (Irish Health Repository)

    Allen, Finbarr

    2011-03-15

    Factors influencing clinical treatment of partially dentate patients are varied, and there is a need to identify factors influencing success in the provision of removable partial dentures. The aim of this study was to assess the attitudes of general dental practitioners (GDPs) in Ireland towards tooth replacement and use of RPDs, in partially dentate older adults. The sample frame was the Register of Dentists in Ireland; data were also collected from a sample of dentists practising under NHS regulations in Northern Ireland. Validated questionnaires were sent to all dentists on the Register of Dentists in the Republic of Ireland, and dentists working under NHS regulations registered with the Central Services Agency in Northern Ireland. Content of the questionnaire included details of the dentist themselves, their dental practice and the profile of partial denture provision. They were also asked to give their views on factors influencing the success or failure of an RPD, the process of providing RPDs and their attitudes to RPD provision. A total of 1,143 responses were received, a response rate of 45%. A mean number of 61 RPDs per annum were provided, with 75% of dentures provided being acrylic based. Respondents indicate their belief that cobalt-chromium based dentures had a longer prognosis than acrylic dentures, but less than half (46%) claim to design the frameworks themselves. Patients\\' attitudes are considered influential in the success of RPD provision, and their influence on appearance is considered the most important factor influencing success. The most important factors influencing failure are: the patient not requesting a denture; an RPD restoring unbounded saddles; and, lower RPDs. Although considered important, approximately 60% of the sample do not routinely organise follow-up appointments for patients provided with RPDs. The fee structures in the DTSS and DTBS are considered a barrier to quality in the provision of partial dentures.

  16. Factors influencing the provision of removable partial dentures by dentists in Ireland.

    LENUS (Irish Health Repository)

    Allen, Finbarr

    2010-10-01

    Factors influencing clinical treatment of partially dentate patients are varied, and there is a need to identify factors influencing success in the provision of removable partial dentures. The aim of this study was to assess the attitudes of general dental practitioners (GDPs) in Ireland towards tooth replacement and use of RPDs, in partially dentate older adults. The sample frame was the Register of Dentists in Ireland; data were also collected from a sample of dentists practising under NHS regulations in Northern Ireland. Validated questionnaires were sent to all dentists on the Register of Dentists in the Republic of Ireland, and dentists working under NHS regulations registered with the Central Services Agency in Northern Ireland. Content of the questionnaire included details of the dentist themselves, their dental practice and the profile of partial denture provision. They were also asked to give their views on factors influencing the success or failure of an RPD, the process of providing RPDs and their attitudes to RPD provision. A total of 1,143 responses were received, a response rate of 45%. A mean number of 61 RPDs per annum were provided, with 75% of dentures provided being acrylic based. Respondents indicate their belief that cobalt-chromium based dentures had a longer prognosis than acrylic dentures, but less than half (46%) claim to design the frameworks themselves. Patients\\' attitudes are considered influential in the success of RPD provision, and their influence on appearance is considered the most important factor influencing success. The most important factors influencing failure are: the patient not requesting a denture; an RPD restoring unbounded saddles; and, lower RPDs. Although considered important, approximately 60% of the sample do not routinely organise follow-up appointments for patients provided with RPDs. The fee structures in the DTSS and DTBS are considered a barrier to quality in the provision of partial dentures.

  17. Attachment-retained gingival prosthesis for implant-supported fixed dental prosthesis in the maxilla: a clinical report.

    Science.gov (United States)

    Aparecida de Mattias Sartori, Ivete; Uhlendorf, Yuri; Padovan, Luiz Eduardo Marques; Junior, Paulo Domingos Ribeiro; Melo, Ana Cláudia Moreira; Tiossi, Rodrigo

    2014-12-01

    The rehabilitation of edentulous maxillae is a complex procedure due to the involvement of esthetic and functional requirements. A trial maxillary denture can be used to identify the need for adequate upper lip support when replacing removable complete dentures by implant-fixed dental prostheses. This clinical report describes the outcome of the rehabilitation of an edentulous atrophic maxilla with unfavorable maxillomandibular relationship and deficient upper lip support. A trial denture was fabricated and used to diagnose the need for a prosthesis capable of restoring the upper lip support. The reduced upper lip support was also confirmed by a lateral cephalogram. The patient was rehabilitated by an implant-fixed dental prosthesis associated with an attachment-retained gingival prosthesis. The case presented shows that when loss of upper lip support is detected and the patient does not wish to undergo further surgical reconstruction procedure, the retention of a gingival prosthesis using a ball attachment is a satisfactory treatment option. © 2014 by the American College of Prosthodontists.

  18. Mechanical Properties of Surface-Charged Poly(Methyl Methacrylate as Denture Resins

    Directory of Open Access Journals (Sweden)

    Sang E. Park

    2009-01-01

    Full Text Available The aim of this study was to examine the mechanical properties of a new surface-modified denture resin for its suitability as denture base material. This experimental resin is made by copolymerization of methacrylic acid (MA to poly(methyl methacrylate (PMMA to produce a negative charge. Four experimental groups consisted of Orthodontic Dental Resin (DENTSPLY Caulk as a control and three groups of modified PMMA (mPMMA produced at differing ratios of methacrylic acid (5 : 95, 10 : 90, and 20 : 80 MA : MMA. A 3-point flexural test using the Instron Universal Testing Machine (Instron Corp. measured force-deflection curves and a complete stress versus strain history to calculate the transverse strength, transverse deflection, flexural strength, and modulus of elasticity. Analysis of Variance and Scheffe Post-test were performed on the data. Resins with increased methacrylic acid content exhibited lower strength values for the measured physical properties. The most significant decrease occurred as the methacrylic acid content was increased to 20% mPMMA. No significant differences at P<.05 were found in all parameters tested between the Control and 5% mPMMA.

  19. Segmental maxillary distraction with a novel device for closure of a wide alveolar cleft.

    Science.gov (United States)

    Bousdras, Vasilios A; Liyanage, Chandra; Mars, Michael; Ayliffe, Peter R

    2014-01-01

    Treatment of a wide alveolar cleft with initial application of segmental distraction osteogenesis is reported, in order to minimise cleft size prior to secondary alveolar bone grafting. The lesser maxillary segment was mobilised with osteotomy at Le Fort I level and, a novel distractor, facilitated horizontal movement of the dental/alveolar segment along the curvature of the maxillary dental arch. Following a latency period of 4 days distraction was applied for 7 days at a rate of 0.5 mm twice daily. Radiographic, ultrasonographic and clinical assessment revealed new bone and soft tissue formation 8 weeks after completion of the distraction phase. Overall the maxillary segment did move minimising the width of the cleft, which allowed successful closure with a secondary alveolar bone graft.

  20. Influences of age and maxillary anterior teeth status on patient's satisfaction with dental appearance and tooth colour.

    Science.gov (United States)

    Lajnert, Vlatka; Pavičić, Daniela K; Gržić, Renata; Kovač, Zoran; Pahor, Dana; Kuis, Davor; Simonić-Kocijan, Sunčana; Antonić, Robert; Bakarčić, Danko

    2012-06-01

    To study the impact of age, gender, tooth colour and maxillary anterior teeth status on patient's satisfaction with their dental appearance. A total of 259 Caucasian subjects participated in the study (119 men, mean age 56 years; 140 women, mean age 61 years) divided into three age groups (young colour using a scale with three categories: completely dissatisfied, moderately dissatisfied and completely satisfied. Almost half of the participants were completely satisfied with their dental appearance and tooth colour. Half of the 'young' and 'middle-aged' participants with natural maxillary anterior teeth were completely satisfied and half of the 'old' participants were moderately satisfied with their dental appearance and tooth colour. The majority of participants with composite restorations (45-51%) were moderately satisfied with their dental appearance, one-third of 'young' and 'middle-aged' participants were moderately satisfied or dissatisfied with their tooth colour and more than 70% of older participants were dissatisfied with their tooth colour (p > 0.05). Satisfaction with the appearance of the maxillary anterior teeth differed both between individuals of different age and different dental status. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  1. Changes in speech following maxillary distraction osteogenesis.

    Science.gov (United States)

    Guyette, T W; Polley, J W; Figueroa, A; Smith, B E

    2001-05-01

    The purpose of this study was to describe changes in articulation and velopharyngeal function following maxillary distraction osteogenesis. This is a descriptive, post hoc clinical report comparing the performance of patients before and after maxillary distraction. The independent variable was maxillary distraction while the dependent variables were resonance, articulation errors, and velopharyngeal function. The data were collected at a tertiary health care center in Chicago. The data from pre- and postoperative evaluations of 18 maxillary distraction patients were used. The outcome measures were severity of hypernasality and hyponasality, velopharyngeal orifice size as estimated using the pressure-flow technique, and number and type of articulation errors. At the long-term follow-up, 16.7% exhibited a significant increase in hypernasality. Seventy-five percent of patients with preoperative hyponasality experienced improved nasal resonance. Articulation improved in 67% of patients by the 1-year follow-up. In a predominately cleft palate population, the risk for velopharyngeal insufficiency following maxillary distraction is similar to the risk observed in Le Fort I maxillary advancement. Patients being considered for maxillary distraction surgery should receive pre- and postoperative speech evaluations and be counseled about risks for changes in their speech.

  2. Endoscopic partial medial maxillectomy with mucosal flap for maxillary sinus mucoceles.

    Science.gov (United States)

    Durr, Megan L; Goldberg, Andrew N

    2014-01-01

    To describe a technique of endoscopic medial maxillectomy with mucosal flap for postoperative maxillary sinus mucoceles and to present a case series of subjects who underwent this procedure. This case series includes four subjects with postoperative maxillary sinus mucoceles who underwent resection via endoscopic partial medial maxillectomy with a mucosal flap. We will discuss the clinical presentation, imaging characteristics, operative details, and outcomes. Four subjects are included in this study. The average age at the time of medial maxillectomy was 52 years (range 35-65 years). Three subjects (75%) were female. One subject (25%) had bilateral postoperative maxillary sinus mucoceles. Two subjects (50%) had unilateral right sided mucoceles, and the remaining subject had a unilateral left sided mucocele. All subjects had a history of multiple sinus procedures for chronic sinusitis including Caldwell-Luc procedures ipsilateral to the postoperative mucocele. All subjects underwent endoscopic medial maxillectomy without complication and were symptom free at the last follow up appointment, average 24 months (range 3-71 months) after medial maxillectomy. For postoperative maxillary sinus mucoceles in locations that are difficult to access via the middle meatus antrostomy, we recommend endoscopic medial maxillectomy with mucosal flap. Our preliminary experience with four subjects demonstrates complete resolution of symptoms after this procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Photodynamic antimicrobial therapy in the treatment of denture stomatitis

    International Nuclear Information System (INIS)

    Senna, Andre Machado de

    2012-01-01

    Denture stomatitis (DS), also called chronic atrophic candidiasis, is the most common oral fungal infection in denture wearers. It has a multifactorial etiology, but the presence of Candida spp. biofilm on the denture is considered the most important factor for the establishment of the DS. This study aimed to evaluate the treatment of DS through the use of photodynamic antimicrobial therapy (PAT), mediated by methylene blue. For this purpose, preclinical studies and clinical trials were performed. Simulators prototypes dentures were made of methyl methacrylate polymer to serve as a basis for biofilm growth of the following species of Candida: C. albicans, C. glabrata, C. dubliniensis, C. krusei, C. tropicalis, C. parapsilosis and C. guilliermondii. Methylene blue solution at a concentration of 450 μg/mL was used as a photosensitizer. The prototypes and biofilms were irradiated with a laser of wavelength of 660 nm, potency of 100 mW, for 80 seconds. For the clinical study, subjects were divided into two groups. The first group received conventional treatment based on the use of antifungal Miconazole. The second group received the treatment by PAT. The preclinical results showed that all species of the genus Candida were susceptible to PAT, with a reduction in colonies that ranged from 2.48 to 3.93 log 10 . Clinical outcomes were evaluated for the reduction of colonies of Candida spp. located in the mucosa and in the prosthesis and relative to the improvement of the clinical aspect of the affected mucosa. Both the conventional therapy and PAT were effective in treating DS. There was no significant statistical difference between PAT and conventional treatment for any of the factors evaluated. Thus, it was concluded that PAT is effective in the treatment of denture stomatitis. (author)

  4. A comparative study for plaque removing efficacy between commonly used denture cleansers in India

    Directory of Open Access Journals (Sweden)

    Bhushan Kumar

    2017-01-01

    Conclusions: There was no significant difference among action of four denture cleansers used in this study. Thus we can infer that patients can use liquid handwashing soap or commercial products to overcome disadvantages of toothpastes. Recommendation from the results of this study is the use of liquid handwashing soap for cleansing after every meal and soaking of the denture in commercial denture cleanser during the night.

  5. Maxillary distraction in patients with cleft deformity using a rigid external distraction device: a pilot study on the distraction ratio of the maxilla to the device.

    Science.gov (United States)

    Harada, Kiyoshi; Sato, Masaru; Omura, Ken

    2004-01-01

    We examined the ratio between actual maxillary distraction and the distraction of the rigid external distraction device (Rigid external distraction (RED) system) used for maxillary distraction in patients with a cleft deformity. Twelve patients were examined. The amount of maxillary advancement was measured on lateral cephalograms and divided by the activation amount on the RED system. The value obtained was represented as the distraction ratio of the maxilla to the system. The mean ratio in 10 patients with complete cleft lip, palate, and alveolus (complete cleft) was 0.24. However, the ratios in two patients with cleft lip and alveolus or soft cleft palate (incomplete cleft) were considerably higher than the mean ratios in patients with complete cleft. When the maxilla is distracted in patients with complete cleft using the RED system, the amount of activation on the system needs to be about four times the amount of planned maxillary distraction. However, the distraction ratio may be affected by the type of cleft.

  6. Interrelationship between implant and orthognathic surgery for the rehabilitation of edentulous cleft palate patients: a case report

    Directory of Open Access Journals (Sweden)

    José Fernando Scarelli LOPES

    2015-04-01

    Full Text Available A 43-year-old woman with a unilateral cleft lip and palate, presenting a totally edentulous maxilla and mandible with marked maxillomandibular discrepancy, attended the Prosthodontics section of the Hospital for Rehabilitation of Craniofacial Anomalies, University of São Paulo for treatment. She could not close her mouth and was dissatisfied with her complete dentures. Treatment planning comprised placement of six implants in the maxilla, four in the mandible followed by prostheses installation and orthognathic surgery. The mandibular full arch prosthesis guided the occlusion for orthognathic positioning of the maxilla. The maxillary complete prosthesis was designed to assist the orthognathic surgery with a provisional prosthesis (no metal framework, allowing reverse treatment planning. Maxillary and mandibular realignment was performed. Three months later, a relapse in the position of the maxilla was observed, which was offset with a new maxillary prosthesis. This isa complex interdisciplinary treatment and two-year follow-up is presented and discussed. It should be considered that this type of treatment could also be applied in non-cleft patients.

  7. Preoperative Cleft Lip Measurements and Maxillary Growth in Patients With Unilateral Cleft Lip and Palate.

    Science.gov (United States)

    Antonarakis, Gregory S; Tompson, Bryan D; Fisher, David M

    2016-11-01

    Maxillary growth in patients with cleft lip and palate is highly variable. The authors' aim was to investigate associations between preoperative cleft lip measurements and maxillary growth determined cephalometrically in patients with complete unilateral cleft lip and palate (cUCLP). Retrospective cross-sectional study. Children with cUCLP. Preoperative cleft lip measurements were made at the time of primary cheiloplasty and available for each patient. Maxillary growth was evaluated on lateral cephalometric radiographs taken prior to any orthodontic treatment and alveolar bone grafting (8.5 ± 0.7 years). The presence of associations between preoperative cleft lip measurements and cephalometric measures of maxillary growth was determined using regression analyses. In the 58 patients included in the study, the cleft lateral lip element was deficient in height in 90% and in transverse width in 81% of patients. There was an inverse correlation between cleft lateral lip height and transverse width with a β coefficient of -0.382 (P = .003). Patients with a more deficient cleft lateral lip height displayed a shorter maxillary length (β coefficient = 0.336; P = .010), a less protruded maxilla (β coefficient = .334; P = .008), and a shorter anterior maxillary height (β coefficient = 0.306; P = .020) than those with a less deficient cleft lateral lip height. Patients with cUCLP present with varying degrees of lateral lip hypoplasia. Preoperative measures of lateral lip deficiency are related to later observed deficiencies of maxillary length, protrusion, and height.

  8. Measurement of Mucosal Thickness in Denture-bearing Area of Edentulous Mandible

    Directory of Open Access Journals (Sweden)

    Jian Dong

    2015-01-01

    Full Text Available Background: The thickness of the alveolar mucosa influences the probability of the occurrence of denture-induced irritations. Thick denture-supporting tissues offer relief from mucosal tenderness and ulcers; however, the uniformity of the thickness across the entire mandibular alveolar mucosa cannot be accurately determined in edentulous patients. This study aimed to assess the mucosal thickness of the denture-bearing area in the edentulous mandible. Methods: Twenty-seven edentulous patients underwent cone-beam computed tomography scanning, wherein the patients wore a record base to retract soft tissues away from the alveolar mucosa. The measured regions were the central incisor (IC, lateral incisor (IL, canine (Ca, first premolar (P1, second premolar (P2, first molar (M1, and second molar (M2 regions. The thickness was measured in the alveolar ridge crest (T, buccal (B1-B4, and lingual (L1-L4 alveolar ridge mucosa. The average thickness of the mucosa at buccal sides (B and lingual sides (L were also assessed. Results: The differences in the mucosal thickness between the left and right sides were not significant. In the Ca-M2 regions, T was the thickest, and L3 was the thinnest of all the measured points in the same regions. L was significantly less than B in posterior regions (P < 0.01. On the other hand, M2 at L4 was thinnest of all the measured regions from Ca to M2 (P < 0.01, and was thicker than IC, IL, P1, and P2 at B2. Conclusions: Since the mucosal thickness of denture-bearing area in the edentulous mandible is not uniform; the tissue surface of the denture base or custom tray should be selectively relieved, which may reduce the risk of denture-induced irritations.

  9. Detection of improvement in the masticatory function from old to new removable partial dentures using mixing ability test.

    Science.gov (United States)

    Asakawa, A; Fueki, K; Ohyama, T

    2005-09-01

    The aim of this study was to determine the sensitivity of the Mixing Ability Test to detect improvement of masticatory function in subjects on transition from old to new removable partial dentures. Thirty-two subjects (seven males, 25 females, mean age 65.0 years) with distal extension partially edentulous area in mandible and/or maxilla participated in the study. The following reasons were presented for replacing the old removable partial dentures with new ones: fracture and/or poor fitness of retainers, extraction of abutment teeth, poor fitness of denture base, severe wear of artificial teeth and request for metal base dentures. Masticatory function with old and new removable partial dentures after an adaptation period (mean 27.4 weeks) was evaluated by the Mixing Ability Test. Subjects were asked to masticate five two-coloured wax cubes with each removable partial denture. Mixing Ability Index was obtained from the colour mixture and shape of the masticated cubes. Wilcoxon signed-rank test was used to test the difference of Mixing Ability Indexes between old and new removable partial dentures. The mixing ability indexes with new removable partial dentures (mean+/- s.d.: 0.70+/- 0.68) was significantly higher (Premovable partial dentures (-0.11+/-1.13). The results suggest that the Mixing Ability Test was capable of detecting improvement in masticatory function with new removable partial dentures.

  10. Blood-flow change and recovery of sensibility in the maxillary dental pulp during and after maxillary distraction: a pilot study.

    Science.gov (United States)

    Harada, Kiyoshi; Sato, Masaru; Omura, Ken

    2004-11-01

    To examine the change in blood flow and recovery of sensibility in the maxillary dental pulp during and after maxillary distraction. The subjects included 5 patients undergoing high Le Fort I osteotomy and maxillary distraction (D-group) and a reference group of 14 patients who underwent a common single-segment Le Fort I osteotomy, 1-stage maxillary advancement, and mandibular setback surgery (C-group). Eleven (D-group) and 54 (C-group) maxillary incisors were assessed preoperatively and at 1-7 days, 14 days, and 3 months postoperatively. Pulpal blood flow (PBF) was measured by laser Doppler flowmetry, and pulpal sensibility (PS) was investigated by electrodiagnostics. From postoperative days 1 to 5 (the latency period), the PBF tended to be higher in the D-group than in the C-group. From day 6 to 3 months postoperatively (during and after maxillary distraction), the PBF values of the 2 groups were similar. The PS remained negative up to 14 days postoperatively in both groups. However, at 3 months after the operation, a higher proportion (90.9%) of teeth in the D-group was positive for PS. These results suggest that maxillary distraction is a favorable technique for maintenance of PBF and recovery of PS in the maxillary teeth after surgery.

  11. CT-MPR invaluable in diagnosing odontogenic maxillary sinusitis

    International Nuclear Information System (INIS)

    Aoki, Hideaki; Shimazu, Kaoru; Kamada, Morito; Shiroyama, Akihiro; Mouri, Daisuke; Yamashita, Masashi; Kawasaki, Yasunori; Koseki, Takakazu; Mouri, Manabu

    2001-01-01

    In everyday examination, it is usual to encounter odontogenic maxillary sinusitis patients. Odontogenic maxillary sinusitis is generally best diagnosed by dental X-ray imaging. Many medical facilities not having a dental X-ray unit use coronal computed tomography (CT) images to diagnose odontogenic maxillary sinusitis. Coronal CT imaging causes artifacts, however due to dental prosthesises. Computed tomography-Multiplanar reformation (CT-MPR) imaging has proved useful in evaluating the paranasal sinus because it is not influenced by dental prosthesises. We evaluated the usefulness of CT-MPR for diagnosing odontogenic maxillary sinusitis by retrospectively analyzing 16 patients, with the following results. We couldn't diagnose all cases of odontogenic maxillary sinusitis in posteroanterior and Waters projection images. Panoramic radiography is needed to diagnose odontogenic maxillary sinusitis. Dental X-ray imaging missed some cases, but all cases were diagnosed by CT-MPR imaging, giving a 100% diagnosestic rate. CT-MPR imaging is thus at least as valuable or better than dental X-ray imaging in diagnosing odontogenic maxillary sinusitis. (author)

  12. Patient’s Satisfaction with Removable Partial Dentures: A Retrospective Case Series

    Science.gov (United States)

    Shala, Kujtim Sh.; Dula, Linda J.; Pustina-Krasniqi, Teuta; Bicaj, Teuta; Ahmedi, Enis F.; Lila-Krasniqi, Zana; Tmava-Dragusha, Arlinda

    2016-01-01

    This retrospective clinical study aimed to assess patient’s satisfaction with removable partial dentures (RPDs), as retention, chewing ability, aesthetics during the observation period. Material and Methods: A total of 63 patients with RPDs, participated in this study. The following data was collected: Kennedy classification, denture design, denture support, satisfaction and success of RPD. Result: The results showed that 73.6% of patients were wearing RPD for the first time and were finally satisfied. According to the denture support of RPDs, clasp-retained quadrangular RPDs were 100% effective, followed by triangular dental support 81% and linear dental support 47.7%. Comparison of RPDs with attachment with RPDs with claps assessed through Fisher exact test, confirmed statistically significant difference (P=0.008), despite retention; however, chewing ability and aesthetics showed no statistically significant difference with X 2 test on patient’s satisfaction with RPD with or without attachment. Conclusion: Patients often would prefer not showing the anterior buccal clasps of RPD, therefore are generally satisfied more with RPD with attachment based on level of retention, chewing ability and aesthetics. PMID:28077970

  13. Estimate of Impact on the Oral Health-Related Quality of Life of Older Thai People by the Provision of Dentures through the Royal Project.

    Science.gov (United States)

    Srisilapanan, Patcharawan; Korwanich, Narumanas; Jienmaneechotchai, Sutha; Dalodom, Supranee; Veerachai, Nontalee; Vejvitee, Warangkana; Roseman, Jeffrey

    2016-01-01

    Purpose. To estimate the impact of the provision of dentures to Thai older people by the Royal Project on their oral health-related quality of life. Methods. A purposive cross-sectional study of a sample of 812 subjects was conducted. The Oral Impacts on Daily Performances (OIDP) measure was used to assess the oral health-related quality of life. Results. Four groups of older people with different tooth types were studied. 216 (26.6%) had natural teeth (NT). 189 (23.3%) had natural and replaced teeth (NRT). 167 (20.6%) had below the minimum number of teeth but had no dentures (Edent) and 240 were edentate with complete dentures provided by the Royal Project (ECD) (29.6%). Overall, 36.5% had at least one oral impact. Eating was the most affected oral impact. When compared to the group with natural teeth (NT), the Edent group was significantly more likely to report having impacts on eating OR = 6.5 (3.9-10.9), speaking clearly OR = 43.7 (12.7-15.07), emotional stability OR = 16.5 (6.0-45.6), and social contacts OR = 4.6 (2.2-9.5) (p < 0.001). Conclusion. Those who are edentulous are much more likely to have an oral impact on their daily performances than those provided dentures. Provision of dentures may lead to improvement of considerable oral impacts.

  14. Prefabricated light-polymerizing plastic pattern for partial denture framework

    Directory of Open Access Journals (Sweden)

    Atsushi Takaichi

    2011-01-01

    Full Text Available Our aim is to report an application of a prefabricated light-polymerizing plastic pattern to construction of removable partial denture framework without the use of a refractory cast. A plastic pattern for the lingual bar was adapted on the master cast of a mandibular Kennedy class I partially edentulous patient. The pattern was polymerized in a light chamber. Cobalt-chromium wires were employed to minimize the potential distortion of the plastic framework. The framework was carefully removed from the master cast and invested with phosphate-bonded investment for the subsequent casting procedures. A retentive clasp was constructed using 19-gauge wrought wire and was welded to the framework by means of laser welding machine. An excellent fit of the framework in the patient′s mouth was observed in the try-in and the insertion of the denture. The result suggests that this method minimizes laboratory cost and time for partial denture construction.

  15. [Radiologic picture of maxillary sinus aspergilloma].

    Science.gov (United States)

    Kaczmarek, I; Bilska, J; Osmola, K; Nowaczyk, M T

    2010-06-01

    Mycotic infection of paranasal sinus could be the etiological factor of chronic sinusitis. The increase in number of fungal sinusitis cases have been reported recently among nonimmunocompromised patient after endodontic treatment of maxillary teeth. Nonspecific clinical signs and incorrect radiologic pictures interpretation as well as loss of therapeutic standards seems to be the cause of false negative diagnosis and difficulties in treatment of fungal sinusitis. Clinical and radiological picture of maxillary sinus aspergillosis was described in this paper. In the period of 2006-2009 in the Department of Maxillo-Facial Surgery 19 patient with fungal maxillary sinusitis was treated. The endodontic treatment of maxillary teeth of the related side was performed previously in 80% examined cases. In 2 cases there were immunocompromised patients with immunosuppressive treatment. In 16 cases patients were referred to our Department due to metallic foreign body of the maxillary sinus. Routine diagnostic radiological imaging was performed in each case: paranasal sinus view--Water's view and panoramic radiograph (orthopantomograph). In 4 cases imaging was extended with computer tomography (CT) visualization. The surgical treatment was performed in each case. The final diagnosis was puted on histopathological examination and fungal culture. In 16 cases of analysed group histopathological examination and fungal culture revealed aspergilosis. In 2 cases fungal culture was negative, but histopathology slices confirm presence of hyphae of Aspergillus. In 1 case the root canal sealer was found in the maxillary sinus. In none case invasive form of aspergillosis was confirmed. In all cases Water's view of paranasal sinuses and ortopantomograph showed partially or totally clouded sinus with well-defined, single or multifocal radiopaque object similar to metallic foreign body. Characteristic finding in CT imaging was well-defined radiodence concretions that have been attributed to

  16. [Resin-bonded fixed partial dentures

    NARCIS (Netherlands)

    Kreulen, C.M.; Creugers, N.H.J.

    2013-01-01

    A resin-bonded fixed partial denture is a prosthetic construction which can replace I or several teeth in an occlusal system and which comprises a pontic element which is adhesively attached to 1 or more abutment teeth. To compensate for the limited shear strength of the adhesive layer, the Jixed

  17. Observation of horizontal mandibular positions in an edentulous patient using a digital gothic arch tracer: a clinical report.

    Science.gov (United States)

    Watanabe, Yoshiyuki

    2004-01-01

    Dentures were fabricated for a 73-year-old woman using porcelain 20-degree maxillary posterior teeth and acrylic resin flat planes in the mandibular posterior region. A digital gothic arch tracing device was used to observe the horizontal mandibular positions before insertion and to evaluate the therapeutic effect of the diagnostic dentures at 1 and 3 months after insertion.

  18. Occlusal plane change after intrusion of maxillary posterior teeth by microimplants to avoid maxillary surgery with skeletal Class III orthognathic surgery.

    Science.gov (United States)

    Park, Hyo-Sang; Kim, Ji-Yeun; Kwon, Tae-Geon

    2010-11-01

    To increase stability and mandibular setback movement, surgical maxillary impaction is normally performed with mandibular setback surgery in treating adult skeletal Class III patients. This article demonstrates the use of microimplants for anchorage to intrude molars and the resultant rotation of the maxillary occlusal plane clockwise to increase the surgical mandibular setback and reduce the posterior vertical dimension instead of maxillary surgical impaction. A 21-year-old man with mandibular prognathism was treated with mandibular setback surgery that included orthodontic treatment for decompensation. Microimplants placed into the palatal alveolar bone between the maxillary first and second molars were used to intrude the maxillary posterior teeth and change the occlusal plane clockwise. This produced 4 mm more of distal movement of the chin during mandibular setback surgery compared with the surgical prediction with no change in the occlusal plane. These results were similar to those of 2-jaw surgery with maxillary posterior impaction. The intrusion of the maxillary posterior teeth with microimplants might prevent the need for maxillary surgery in adult skeletal Class III patients. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  19. 21 CFR 872.3450 - Ethylene oxide homopolymer and/or karaya denture adhesive.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide homopolymer and/or karaya denture... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3450 Ethylene oxide homopolymer and/or karaya denture adhesive. (a) Identification. Ethylene oxide homopolymer and/or karaya...

  20. Anterior maxillary segmental distraction for correction of maxillary hypoplasia and dental crowding in cleft palate patients: a preliminary report.

    Science.gov (United States)

    Wang, X-X; Wang, X; Li, Z-L; Yi, B; Liang, C; Jia, Y-L; Zou, B-S

    2009-12-01

    To evaluate the feasibility of anterior maxillary segmental distraction (AMSD) to correct maxillary hypoplasia and severe dental crowding in cleft lip and palate (CLP) patients, 7 patients (average age 16.4 years) with maxillary hypoplasia, shortened maxillary dental arch length and severe anterior dental crowding secondary to CLP were selected for this study. After anterior maxillary segmental osteotomy, 3 patients were treated using bilateral internal distraction devices, and 4 patients were treated using rigid external distraction devices. Photographs and radiographs were taken to review the improvement in facial profile and occlusion after distraction. An average 10.25 mm anterior maxillary advancement was obtained in all patients after 10-23 days of distraction and 9-16 weeks of consolidation. The sella-nasion-point A (SNA) angle increased from 69.5 degrees to 79.6 degrees. Midface convexity was greatly improved and velopharyngeal competence was preserved. The maxillary dental arch length was greatly increased by 10.1 mm (P<0.01). Dental crowding and malocclusion were corrected by orthodontic treatment. These results show that AMSD can effectively correct the hypoplastic maxilla and severe dental crowding associated with CLP by increasing the midface convexity and dental arch length while preserving velopharyngeal function, and dental crowding can be corrected without requiring tooth extraction.

  1. Fracture strength and bending of all-ceramic and fiber-reinforced composites in inlay-retained fixed partial dentures

    Directory of Open Access Journals (Sweden)

    Serkan Saridag

    2012-06-01

    Conclusions: Zirconia-based ceramic inlay-retained fixed partial dentures demonstrated the highest fracture strength. The fiber-reinforced composite inlay-retained fixed partial dentures demonstrated higher bending values than did the all-ceramic inlay-retained fixed partial dentures.

  2. Mastication in subjects with extremely shortened dental arches rehabilitated with removable partial dentures.

    Science.gov (United States)

    Arce-Tumbay, Jackelyn; Sanchez-Ayala, Alfonso; Sotto-Maior, Bruno Salles; Senna, Plinio Mendes; Campanha, Nara Hellen

    2011-01-01

    Mastication was evaluated in subjects presenting extremely shortened dental arches (ESDAs) rehabilitated with mandibular free-end removable partial dentures (RPDs). Subjects were divided into four groups (n = 10): those with a complete dentition, those with ESDAs, and those with ESDAs who were rehabilitated with an RPD, who were evaluated both with and without their prostheses. Mastication was measured through masticatory performance, time, and ability. RPD wearers showed higher masticatory performance (P mastication in ESDA subjects but without achieving normal mastication levels.

  3. Comparison of fixed implant-supported prostheses, removable implant-supported prostheses, and complete dentures: patient satisfaction and oral health-related quality of life.

    Science.gov (United States)

    Oh, Sung-Hee; Kim, Younhee; Park, Joo-Yeon; Jung, Yea Ji; Kim, Seong-Kyun; Park, Sun-Young

    2016-02-01

    The purpose of this study was to compare patient satisfaction and oral health-related quality of life (OHRQoL) among fully edentulous patients treated with either fixed implant-supported prostheses (FP), removable implant-supported prostheses (RP), or complete dentures (CD). Eighty-six patients - 29 FP, 27 RP, and 30 CD patients - participated in this study. The survey was conducted using face-to-face interviews with a questionnaire that included a patient satisfaction scale and Oral Health Impact Profile (OHIP-14). We measured patient satisfaction after prosthetic treatments and OHRQoL before and after the treatments. After prosthetic treatments, OHRQoL increased in all three groups (P patient satisfaction and OHRQoL, and both groups showed greater improvement compared with the CD group. Specifically, the OHRQoL dimensions of functional limitation, physical pain, psychological discomfort, and psychological disability in the FP group, and functional limitation in the RP group, improved greatly in comparison with the CD group (P patient satisfaction than the CD treatment. Reliable information of OHRQoL and patient satisfaction helps experts and patients choose the best prosthetic treatment option. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures.

    NARCIS (Netherlands)

    Creugers, N.H.J.; Witter, D.J.; Spijker, A. van 't; Gerritsen, A.E.; Kreulen, C.M.

    2010-01-01

    Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n = 25) were compared with subjects with shortened dental arches

  5. Maxillary sinus augmentation

    Directory of Open Access Journals (Sweden)

    A B Tarun Kumar

    2015-01-01

    Full Text Available Placing dental implants in the maxillary posterior region can be both challenging and un-nerving for a regular implant dentist who is not well versed with advanced surgical procedures. It is vital for a general dentist to understand the fundamentals of bone grafting the maxillary sinus if he/she is really committed to providing the best health care for their patients. The dental practice is seeing an increasing group of patients who are living longer, and this group of older baby boomers often has an edentulous posterior maxilla either unilateral or bilateral. When edentulous, the posterior maxilla more likely has diminished bone height, which does not allow for the placement of dental implants without creating additional bone. Through grafting the maxillary sinus, bone of ideal quality can be created (allowing for placement of dental implants, which offer many advantages over other tooth replacement modalities. The sinus graft offers the dental patient a predictable procedure of regenerating lost osseous structure in the posterior maxilla. This offers the patient many advantages for long-term success. If dentists understand these concepts, they can better educate their patients and guide them to have the procedure performed. This article outlines bone grafting of the maxillary sinus for the purpose of placing dental implants. This review will help the readers to understand the intricacies of sinus augmentation. They can relate their patient's condition with the available literature and chalk out the best treatment plan for the patient, especially by using indirect sinus augmentation procedures which are less invasive and highly successful if done using prescribed technique.

  6. Radiodiagnostics of maxillary osteomyelitis

    International Nuclear Information System (INIS)

    Klemova, J.; Jenca, A.; Hanusinova, V.; Danko, J.; Ondrasovicova, J.

    2006-01-01

    Osteomyelitis is defined as an inflammation or infection in bone tissues - cancellous bone, bone marrow, bone compacta and periosteum due to invasion of infection from surrounding tissues. Maxillary osteomyelitis is less common disease than osteomyelitis of mandible. This can be explained by anatomical structure of maxilla which is mainly composed of sinuses and thin bone lamellae. Such a structure allows rapid propagation of the infection to the surface. There have been examined and treated 70 patients with osteomyelitis of facial bones within past 15 years at Department of stomatology and maxillo-facial surgery of P.J. Safarik University in Kosice. Only four cases were diagnosed as maxillary osteomyelitis. The aim of this study was to mention the differences in anatomy and symptoms of acute and chronic stage of maxillary osteomyelitis and to give a detailed radiographic picture of this affliction. (authors)

  7. Postoperative Maxillary Cyst: A Case Report

    Directory of Open Access Journals (Sweden)

    Asiye Şafak Bulut

    2010-01-01

    Full Text Available Postoperative maxillary cyst is a quite rare delayed complication of surgical intervention associated with maxillary sinuses. It occurs many years after surgery. This paper describes a 54-year-old woman presenting with swelling of left cheek for seven-years duration. The orthopantomograph revealed a unilocular cystic radiolucency with well-defined margins in left maxillary sinus. In the computerized tomography, the cyst had a sclerotic wall with bony condensations. Aspiration cytology revealed many neutrophil leukocytes. Cyst was drained and enucleated. Histopathologically, it had a fibrous wall with inflammation and focal reactive bone formation and lined by a respiratory-type epithelium. In the clinical history, it is learned that she had a maxillary sinus surgery 8 years ago and the diagnosis was made considering the clinical and histopathological findings.

  8. [Stimulation and evaluation on maxillary distraction osteogenesis using CASSOS 2001].

    Science.gov (United States)

    Zhu, Min; Qiu, Wei-liu; Tang, You-sheng; Li, Qing-yun

    2002-09-01

    To simulate maxillary distraction osteogenesis and evaluate the change of soft and hard tissue before and after treatment, using Computer-Assisted Simulation System for Orthognathic Surgery( CASSOS 2001). A fourteen-year-old boy with severe maxillary hypoplasia, due to unilateral cleft lip and palate, was analysed by cephalometric analysis. The simulations of maxillary distraction osteogenesis (Le Fort I osteotomy and Le Fort II osteotomy) were re-analysed. After the treatment, cephalometric analysis was preformed again. The data were compared. The maxillary hypoplasia was well treated using maxillary distraction osteogenesis; Compared with Le fort I osteotomy, more satisfactory results can be obtained by Le fort I distraction osteogenesis. Maxillary distraction osteogenesis is a better way to treat severe maxillary hypoplasia with operated CLP than maxillary osteotomy. CASSOS 2001 can help surgeons and patients on simulation and evaluation of maxillary distraction osteogenesis, and on decision of treatment plan.

  9. [Elderly people and removable partial dentures

    NARCIS (Netherlands)

    Baat, C. de

    2009-01-01

    The most frequently reported disadvantages of removable partial dentures are the more demanding daily oral hygiene self-care, especially for people who already experience difficulties in self-care, and the possible harmful influence on the remaining dentition. These disadvantages can be expressed in

  10. Nanoindentation and surface roughness profilometry of poly methyl methacrylate denture base materials.

    Science.gov (United States)

    Zafar, Muhammad Sohail; Ahmed, Naseer

    2014-01-01

    Polymers have a wide range of applications in dentistry. Poly methyl methacrylate (PMMA) is the most popular for making orthodontic retainers, dentures as well as synthetic teeth. Prior to clinical applications, the appliances are polished in the dental laboratory to achieve smooth, polished and comfortable surfaces. The objective of this study was to analyze the surface roughness profiles of PMMA dentures polished using two different approaches. In addition, the effects of ultrasonication and sandblasting were also evaluated on the fitting surface of PMMA dentures. This was an in vitro study using non-contact mode surface roughness profilometer and nano-indenter. Samples were polished using two different techniques (Standard and modified). Both cold cure and heat cure PMMA denture surfaces were evaluated for roughness, nanohardness and elastic modulus. The absolute hardness was recorded 297.72±19.04 MPa and 229.93±18.53 MPa for heat cured PMMA and cold cured PMMA. Manufactured acrylic teeth were harder (319.20±12.58 MPa) with an elastic modulus of (4.34±1.86 GPa). Modified polishing techniques (group 3) produced smoother surface. It was concluded that elastic moduli of acrylic tooth and heat cure PMMA is not very different. Surface treatments such as ultrasonication or sandblasting do not affect the roughness profiles of denture fitting surfaces.

  11. 21 CFR 872.3410 - Ethylene oxide homopolymer and/or carboxymethylcellulose sodium denture adhesive.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide homopolymer and/or....3410 Ethylene oxide homopolymer and/or carboxymethylcellulose sodium denture adhesive. (a) Identification. An ethylene oxide homopolymer and/or carboxymethylcellulose sodium denture adhesive is a device...

  12. Aspergillus in endodontic infection near the maxillary sinus

    Directory of Open Access Journals (Sweden)

    Cinthya Cristina Gomes

    2015-10-01

    Full Text Available ABSTRACT INTRODUCTION: Diseases of the maxillary sinus have been associated with dental roots near the maxillary sinus that have undergone endodontic treatment. OBJECTIVE: To investigate the presence of filamentous fungi in patients with dental roots near the maxillary sinus who had apical periodontitis treated endodontically, and to alert practitioners that this could be a possible avenue of contamination of the sinus in patients who develop maxillary sinus infection. METHODS: Cross-sectional study in 60 palatal roots of the first maxillary molars near the maxillary sinus, that underwent endodontic treatment for apical periodontitis. After removal of the filling material, dentin shavings were collected and placed in test tubes containing Sabouraud dextrose agar and chloramphenicol. The phenotype was determined by macroscopic and microscopic examination of the colonies. For polymerase chain reaction, the primers ITS-5 and ITS-4 were used. The sequences obtained were compared with those deposited at GenBank using the Basic Local Alignment Search Tool program. RESULTS: Filamentous fungi were isolated from 6 of 60 canals (10%:Aspergillus niger (6.7%, Aspergillus versicolor (1.6%, and Aspergillus fumigatus(1.6%. CONCLUSION: Root canals near the maxillary sinus with endodontic treatment and apical periodontitis may exhibit positive cultures for filamentous fungi. Interested professionals should be alert, because these microorganisms have pathogenic characteristics that can cause disease of odontogenic origin in the maxillary sinus.

  13. Comparison of two protocols for maxillary protraction: bone anchors versus face mask with rapid maxillary expansion

    Science.gov (United States)

    Cevidanes, Lucia; Baccetti, Tiziano; Franchi, Lorenzo; McNamara, James A.; De Clerck, Hugo

    2010-01-01

    Objective To test the hypothesis that there is no difference in the active treatment effects for maxillary advancement induced by bone-anchored maxillary protraction (BAMP) and the active treatment effects for face mask in association with rapid maxillary expansion (RME/FM). Materials and Methods This is a study on consecutively treated patients. The changes in dentoskeletal cephalometric variables from start of treatment (T1) to end of active treatment (T2) with an average T1–T2 interval of about 1 year were contrasted in a BAMP sample of 21 subjects with a RME/FM sample of 34 patients. All subjects were prepubertal at T1. Statistical comparison was performed with t-tests for independent samples. Results The BAMP protocol produced significantly larger maxillary advancement than the RME/FM therapy (with a difference of 2 mm to 3 mm). Mandibular sagittal changes were similar, while vertical changes were better controlled with BAMP. The sagittal intermaxillary relationships improved 2.5 mm more in the BAMP patients. Additional favorable outcomes of BAMP treatment were the lack of clockwise rotation of the mandible as well as a lack of retroclination of the lower incisors. Conclusions The hypothesis is rejected. The BAMP protocol produced significantly larger maxillary advancement than the RME/FM therapy. PMID:20578848

  14. Estimate of Impact on the Oral Health-Related Quality of Life of Older Thai People by the Provision of Dentures through the Royal Project

    Directory of Open Access Journals (Sweden)

    Patcharawan Srisilapanan

    2016-01-01

    Full Text Available Purpose. To estimate the impact of the provision of dentures to Thai older people by the Royal Project on their oral health-related quality of life. Methods. A purposive cross-sectional study of a sample of 812 subjects was conducted. The Oral Impacts on Daily Performances (OIDP measure was used to assess the oral health-related quality of life. Results. Four groups of older people with different tooth types were studied. 216 (26.6% had natural teeth (NT. 189 (23.3% had natural and replaced teeth (NRT. 167 (20.6% had below the minimum number of teeth but had no dentures (Edent and 240 were edentate with complete dentures provided by the Royal Project (ECD (29.6%. Overall, 36.5% had at least one oral impact. Eating was the most affected oral impact. When compared to the group with natural teeth (NT, the Edent group was significantly more likely to report having impacts on eating OR = 6.5 (3.9–10.9, speaking clearly OR = 43.7 (12.7–15.07, emotional stability OR = 16.5 (6.0–45.6, and social contacts OR = 4.6 (2.2–9.5 (p<0.001. Conclusion. Those who are edentulous are much more likely to have an oral impact on their daily performances than those provided dentures. Provision of dentures may lead to improvement of considerable oral impacts.

  15. Surgically assisted rapid maxillary expansion in adults.

    Science.gov (United States)

    Pogrel, M A; Kaban, L B; Vargervik, K; Baumrind, S

    1992-01-01

    Twelve adults with maxillary width discrepancy of greater than 5 mm were treated by surgically assisted rapid maxillary expansion. The procedure consisted of bilateral zygomatic buttress and midpalatal osteotomies combined with the use of a tooth-borne orthopedic device postoperatively. Mean palatal expansion of 7.5 mm (range of 6 to 13 mm), measured in the first molar region, was achieved within 3 weeks in all patients. Expansion remained stable during the 12-month study period, with a mean relapse for the entire group of 0.88 +/- 0.48 mm. Morbidity was limited to mild postoperative discomfort. The results of this preliminary study indicated that surgically assisted rapid maxillary expansion is a safe, simple, and reliable procedure for achieving a permanent increase in skeletal maxillary width in adults. Further study is necessary to document the three-dimensional movements of the maxillary segments and long-term stability of the skeletal and dental changes.

  16. A case report of mucoid retention cyst in maxillary sinus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han Pyoung [College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1973-11-15

    The author have observed mucoid retention cyst in the right maxillary sinus of the patient, 41 year old woman, complained discharging of purulent exudate on the right maxillary molar area, and obtained the following conclusions; 1. The mucoid retention cyst in maxillary sinus casts a faint dome shaped shadow into the radiolucent image of maxillary sinus. 2. The mucoid retention cyst in maxillary sinus may occurred without the history of trauma. 3. Intraoral standard films are also valuable for the interpretation of the lesions in maxillary sinus but only extraoral roentgenograms.

  17. Effect of surface treatments on the bond strength of soft denture lining materials to an acrylic resin denture base.

    Science.gov (United States)

    Gundogdu, Mustafa; Yesil Duymus, Zeynep; Alkurt, Murat

    2014-10-01

    Adhesive failure between acrylic resin and resilient liner material is commonly encountered in clinical practice. The purpose of this study was to evaluate the effect of different surface treatments on the bond strength of 2 different resilient lining materials to an acrylic resin denture base. Ninety-six dumbbell-shaped specimens were fabricated from heat-polymerized acrylic resin, and 3 mm of the material was cut from the thin midsection. The specimens were divided into 6 groups according to their surface treatments: no surface treatment (control group), 36% phosphoric acid etching (acid group), erbium:yttrium-aluminum-garnet (Er:YAG) laser (laser group), airborne-particle abrasion with 50-μm Al2O3 particles (abrasion group), an acid+laser group, and an abrasion+laser group. The specimens in each group were divided into 2 subgroups according to the resilient lining material used: heat-polymerized silicone based resilient liner (Molloplast B) and autopolymerized silicone-based resilient liner (Ufi Gel P). After all of the specimens had been polymerized, they were stored in distilled water at 37°C for 1 week. A tensile bond strength test was then performed. Data were analyzed with a 2-way ANOVA, and the Sidak multiple comparison test was used to identify significant differences (α=.05). The effects of the surface treatments and resilient lining materials on the surface of the denture base resin were examined with scanning electron microscopy. The tensile bond strength was significantly different between Molloplast B and Ufi Gel P (P<.001). The specimens of the acid group had the highest tensile bond strength, whereas those of the abrasion group had the lowest tensile bond strength. The scanning electron microscopy observations showed that the application of surface treatments modified the surface of the denture base resin. Molloplast B exhibited significantly higher bond strength than Ufi Gel P. Altering the surface of the acrylic resin denture base with 36

  18. Aspergillus in endodontic infection near the maxillary sinus.

    Science.gov (United States)

    Gomes, Cinthya Cristina; Pinto, Larissa Christina Costa; Victor, Fernanda Loretti; Silva, Erlange Andrade Borges da; Ribeiro, Apoena de Aguiar; Sarquis, Maria Inês de Moura; Camões, Isabel Coelho Gomes

    2015-01-01

    Diseases of the maxillary sinus have been associated with dental roots near the maxillary sinus that have undergone endodontic treatment. To investigate the presence of filamentous fungi in patients with dental roots near the maxillary sinus who had apical periodontitis treated endodontically, and to alert practitioners that this could be a possible avenue of contamination of the sinus in patients who develop maxillary sinus infection. Cross-sectional study in 60 palatal roots of the first maxillary molars near the maxillary sinus, that underwent endodontic treatment for apical periodontitis. After removal of the filling material, dentin shavings were collected and placed in test tubes containing Sabouraud dextrose agar and chloramphenicol. The phenotype was determined by macroscopic and microscopic examination of the colonies. For polymerase chain reaction, the primers ITS-5 and ITS-4 were used. The sequences obtained were compared with those deposited at GenBank using the Basic Local Alignment Search Tool program. Filamentous fungi were isolated from 6 of 60 canals (10%): Aspergillus niger (6.7%), Aspergillus versicolor (1.6%), and Aspergillus fumigatus (1.6%). Root canals near the maxillary sinus with endodontic treatment and apical periodontitis may exhibit positive cultures for filamentous fungi. Interested professionals should be alert, because these microorganisms have pathogenic characteristics that can cause disease of odontogenic origin in the maxillary sinus. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  19. Characterization and bacterial anti-adherent effect on modified PMMA denture acrylic resin containing platinum nanoparticles

    OpenAIRE

    Nam, Ki-Young

    2014-01-01

    PURPOSE This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material. MATERIALS AND METHODS Polymerized PMMA denture acrylic disc (20 mm × 2 mm) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transm...

  20. Pressure transmission area and maximum pressure transmission of different thermoplastic resin denture base materials under impact load.

    Science.gov (United States)

    Nasution, Hubban; Kamonkhantikul, Krid; Arksornnukit, Mansuang; Takahashi, Hidekazu

    2018-01-01

    The purposes of the present study were to examine the pressure transmission area and maximum pressure transmission of thermoplastic resin denture base materials under an impact load, and to evaluate the modulus of elasticity and nanohardness of thermoplastic resin denture base. Three injection-molded thermoplastic resin denture base materials [polycarbonate (Basis PC), ethylene propylene (Duraflex), and polyamide (Valplast)] and one conventional heat-polymerized acrylic resin (PMMA, SR Triplex Hot) denture base, all with a mandibular first molar acrylic resin denture tooth set in were evaluated (n=6). Pressure transmission area and maximum pressure transmission of the specimens under an impact load were observed by using pressure-sensitive sheets. The modulus of elasticity and nanohardness of each denture base (n=10) were measured on 15×15×15×3mm 3 specimen by using an ultramicroindentation system. The pressure transmission area, modulus of elasticity, and nanohardness data were statistically analyzed with 1-way ANOVA, followed by Tamhane or Tukey HSD post hoc test (α=.05). The maximum pressure transmission data were statistically analyzed with Kruskal-Wallis H test, followed by Mann-Whitney U test (α=.05). Polymethyl methacrylate showed significantly larger pressure transmission area and higher maximum pressure transmission than the other groups (Pelasticity and nanohardness among the four types of denture bases (Pelasticity and nanohardness of each type of denture base were demonstrated. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  1. Characterization and bacterial anti-adherent effect on modified PMMA denture acrylic resin containing platinum nanoparticles.

    Science.gov (United States)

    Nam, Ki-Young

    2014-06-01

    This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material. Polymerized PMMA denture acrylic disc (20 mm × 2 mm) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transmission electron microscopy), SEM/EDX (scanning electron microscope/energy dispersive X-ray spectroscopy), thermogravimetric and atomic absorption spectrophotometer analysis. In antimicrobial assay, specimens were placed on the cell culture plate, and 100 µL of microbial suspensions of S. mutans (Streptococcus mutans) and S. sobrinus (Streptococcus sobrinus) were inoculated then incubated at 37℃ for 24 hours. The bacterial attachment was tested by FACS (fluorescence-activated cell sorting) analysis after staining with fluorescent probe. PtN were successfully loaded and uniformly immobilized into PMMA denture acrylic with a proper thermal stability and similar surface morphology as compared to control. PtNC expressed significant bacterial anti-adherent effect rather than bactericidal effect above 50 mg/L PtN loaded when compared to pristine PMMA (P=.01) with no or extremely small amounts of Pt ion eluted. This is the first report on the synthesis and its antibacterial activity of Pt-PMMA nanocomposite. PMMA denture acrylic loading PtN could be a possible intrinsic antimicrobial denture material with proper mechanical characteristics, meeting those specified for denture bases. For clinical application, future studies including biocompatibility, color stability and warranting the long-term effect were still required.

  2. Breakage of internal maxillary distractor: considerable complication of maxillary distraction osteogenesis.

    Science.gov (United States)

    Aikawa, Tomonao; Iida, Seiji; Isomura, Emiko T; Namikawa, Mari; Matsuoka, Yudai; Yamada, Chiaki; Yamamoto, Taku; Takigawa, Yoko

    2008-07-01

    Maxillary distraction osteogenesis using intraoral distractors is now one of the standard treatments of maxillary retrusion. This report shows 2 cases of breakage of this internal maxillary distractor in patients with cleft lip and palate; one was observed during the distraction period and the other was during the retention period. The first case required a rotational movement of the distraction segment, and this movement caused the laterally dislocation of the posterior part of the distractor, where the distractor suffered some mechanical forces by mouth opening. In the latter case, breakage of distractor was observed on the radiographs taken 3 months after distraction and this complication may have been caused by mechanical force by occlusion and mastication. Both breakages were found at the joint of the anchorage plate and the extension rod, which has some flexibility for adjusting the plate to the bone surface. Therefore, surgeons should pay special attention for this mechanical weak area in this distractor not only during the advancement period, but also during the retention period and should avoid unnecessary frequent bending for adopting the bone surface, which directly weakens the joint.

  3. A Survey of Removable Partial Denture (RPD Retentive Elements in Relation to Type of Edentulism and Abutment Teeth in Commercial Laboratories in Athens

    Directory of Open Access Journals (Sweden)

    Michael Sotiriou

    2014-01-01

    Full Text Available Objective. The aim of this survey was to record removable partial denture (RPD retentive elements and abutment teeth in partially edentulous patients, identified in commercial laboratories in Athens, Greece. Material and Methods. 628 master casts with the corresponding cast metal frameworks used in the construction of RPDs were evaluated. Casts were photographed to identify the number and position of existing teeth, the partial edentulism class and the retentive elements. Prevalence tables and the x2 test were used for the statistical analysis of the collected data (α=.05. Results. There were 276 maxillary (43.9% and 352 (56.1% mandibular casts. Maxillary edentulism entailed almost a total absence of right third molars in 96.7% and left third molars 96.0% of casts, with lower rates for the first and second molars. Edentulism in the posterior mandible presented a similar pattern. The most profound findings concerning retentive elements were: 91.9% of the retainers used were clasps and the remaining 8.1% were attachments. Of the clasps used, 48.9% were of the Roach Τ type, a finding more common in Kennedy Class I as compared to other Kennedy Classes (p<0.01. The circumferential clasps accounted for 19.3% of the total clasps used, and it was less frequently presented (8.8% in Kennedy I Classes (p<0.01. Conclusions. Roach clasps were used in the majority of cases whereas RPI clasps and attachments were rarely used.

  4. Volumetric measurement of the maxillary sinus by coronal CT scan

    International Nuclear Information System (INIS)

    Ikeda, Atsuko

    1996-01-01

    The volume of the maxillary sinus was estimated by coronal CT scan. The purpose of this study was to compare the estimated volume of the normal maxillary sinus with that of the inflamed maxillary sinus. Patients were classified following evaluation by CT scan of the paranasal sinuses into 3 categories. Group A (n=12): Patients suffered from headache, facial pain and epistaxis, but CT scans of their nasal cavity and paranasal sinus were within normal limits without inflammatory change. Group B (n=69): Patients with bilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory changes in both maxillary sinuses. All of the patients in this group underwent sinus surgery after coronal CT scans. Group C (n=14): Patients with unilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory change in unilateral maxillary sinuses. CT scans of these patients were measured by Plannimeter to take the area of each image of the maxillary sinus. Consecutively imaged areas were summated by integral calculus to obtain an estimate of the sinus volume. The mean maxillary sinus volume in the affected sinuses was significantly smaller than those in the contralateral normal sinuses (p<0.05, Wilcoxon-test). The various volumes of the maxillary sinuses and the developmental cause were discussed. Comparison of groups A with B suggested three distinct patterns; the maxillary sinus volume has decreased due to inflammatory changes in the bone. The small sinuses have a tendency to develop chronic inflammatory change. The aeration in the maxillary sinus may be decreased when anatomic variations that may obstruct the ethmoid infundibulum exist. (K.H.)

  5. Volumetric measurement of the maxillary sinus by coronal CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Atsuko [Tokyo Medical and Dental Univ. (Japan). School of Medicine

    1996-08-01

    The volume of the maxillary sinus was estimated by coronal CT scan. The purpose of this study was to compare the estimated volume of the normal maxillary sinus with that of the inflamed maxillary sinus. Patients were classified following evaluation by CT scan of the paranasal sinuses into 3 categories. Group A (n=12): Patients suffered from headache, facial pain and epistaxis, but CT scans of their nasal cavity and paranasal sinus were within normal limits without inflammatory change. Group B (n=69): Patients with bilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory changes in both maxillary sinuses. All of the patients in this group underwent sinus surgery after coronal CT scans. Group C (n=14): Patients with unilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory change in unilateral maxillary sinuses. CT scans of these patients were measured by Plannimeter to take the area of each image of the maxillary sinus. Consecutively imaged areas were summated by integral calculus to obtain an estimate of the sinus volume. The mean maxillary sinus volume in the affected sinuses was significantly smaller than those in the contralateral normal sinuses (p<0.05, Wilcoxon-test). The various volumes of the maxillary sinuses and the developmental cause were discussed. Comparison of groups A with B suggested three distinct patterns; the maxillary sinus volume has decreased due to inflammatory changes in the bone. The small sinuses have a tendency to develop chronic inflammatory change. The aeration in the maxillary sinus may be decreased when anatomic variations that may obstruct the ethmoid infundibulum exist. (K.H.)

  6. endodontic treatment of unusually long discolored maxillary central ...

    African Journals Online (AJOL)

    a few cases of dual–rooted maxillary central incisor have been reported in literature1-5. Maxillary central incisors vary in root ... The following case report describes the endodontic management of a patient with an unusually long maxillary central incisor in our environment. CASE PROFILE. A 31 year-old male was referred ...

  7. Prosthetic aspects and patient satisfaction with resilient liner and clip attachments for bar- and implant-retained mandibular overdentures: a 3-year randomized clinical study.

    Science.gov (United States)

    ELsyad, Moustafa Abdou

    2012-01-01

    This report aimed to compare prosthetic aspects and patient satisfaction during a 3-year randomized clinical trial of bar- and implant-retained mandibular overdentures attached with either resilient liners or clips. Thirty edentulous male patients (mean age: 62.5 years) received two implants in the anterior mandible after being allocated into two equal groups (according to attachment type received) using balanced randomization. After 3 months, implants were connected with resilient bars. New maxillary complete dentures were then constructed, and mandibular overdentures were retained to the bars with either clips (group I) or silicone resilient liners (group II). Subjects indicated satisfaction with their prostheses using a questionnaire and visual analog scale. Patient satisfaction and prosthetic complications were recorded for both attachments at 6 months and 1 and 3 years after overdenture insertion. Comfort and stability with the maxillary denture and ease of hygiene procedures were rated higher in group II, while ease of handling the dentures was rated higher in group I. No significant differences in other parameters of patient satisfaction between groups were noted after 3 years. The mean number of prosthetic adjustments and repairs in group I (11.9) was significantly higher (P = .00) compared to that in group II (4.8). The most common complication in group I was clip wear, while separation of the resilient liner from the denture base was the most common problem in group II. Hyperplasia under the bar and flabby ridge in the maxilla occurred significantly more often in group I compared to group II. Resilient liner-retained mandibular overdentures had comparable patient satisfaction, less prosthetic maintenance and costs, and less soft tissue complications when compared to clip-retained ones after 3 years.

  8. Evaluation of Currently Used Dental Management Indicators and Development of New Management and Performance Indicators.

    Science.gov (United States)

    1981-07-01

    Meatal Maxillary Resin 05206 - Cast Metal Mandibular Resin 05862 - Overdenture Maxillary 05863 - Overdenture MandibularI 5 A-5 Selected Fixed...27 195.00 5,265.00 18. 06204 Acrylic Veneered Pontic 25 200.00 5,000.00 .19. 02542 Pin Ledge Restoration 24 178.00 4,272.00 120. 05814 Overdenture ...Amalgam Occlusal, Partial Denture 8 320.00 2,560.00 126. 05863 Overdenture Mandibular 8 320.00 2,560.00 127. 05761 Reline Removable Partial Maxillary

  9. Dual Component Removable Partial Denture shows improved ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-02-18

    Feb 18, 2009 ... 2Faculty of Dentistry, the University of Hong Kong, Hong Kong. 3Department of ... an example of poor oral condition caused mainly by periodontitis, and ... working model of the Dual Component Removable Partial Denture.

  10. Unusual Root Canal Morphology of the Maxillary Second Molar: A Case Report

    Directory of Open Access Journals (Sweden)

    Neslihan Şımşek

    2013-01-01

    Full Text Available Introduction. This clinical case report presents the successful endodontic treatment of a maxillary second molar that has a mandibular molar-like anatomy with no palatal root and with each of its roots containing two separate root canals. Cone-beam computed tomography (CBCT was used to confirm this unusual anatomy. Methods. A 34-year-old male patient was referred to the Department of Endodontics at Inonu University’s Faculty of Dentistry because of severe pain in his right maxillary second molar. Clinical and radiographic examinations identified unusual roots and root canals anatomy, and CBCT was planned in order to understand the nature of these variations. Cleaning and shaping procedures were performed using the crown down technique with Sybron Endo (Glendora, CA, USA rotary instruments, and endodontic treatment was completed with gutta-percha cones and AH Plus resin sealers using the cold lateral compaction technique. Conclusions. The maxillary second molar exhibits aberrations and variations in terms of the numbers and configurations of its roots and root canals, and CBCT can be a useful imaging technique in endodontics.

  11. The use of internal maxillary distraction for maxillary hypoplasia: a preliminary report.

    Science.gov (United States)

    Van Sickels, Joseph E; Madsen, Mathew J; Cunningham, Larry L; Bird, Douglas

    2006-12-01

    Distraction osteogenesis is a useful alternative to advance the maxilla in complicated cases of maxillary hypoplasia. The purpose of this article is to review the workup, experience, and preliminary results with the use of internal distraction osteogenesis for maxillary hypoplasia at one teaching institution. Over a 5-year period, more than 300 patients with craniofacial and dentofacial defects have undergone oral and maxillofacial surgery at our center to correct their skeletal discrepancies. Of these, 10 have had maxillary distraction osteogenesis done with internal distractors. Follow-up of 6 months or more was available for 8 patients. Stereolithographic models were used to bend distractors prior to surgery in 6 patients. Latency prior to the start of distraction was 3 to 7 days and varied with the age of the patient. Distraction occurred at approximately 1 mm per day with an average distraction length of 8.5 mm (range, 6-10 mm). Excellent occlusal results were obtained in 5 patients. Major complications including nonunion and failure to achieve acceptable occlusal results were observed in 3 patients. Minor complications including pain and loosening of the distracter devices were observed in 2 patients, but did not appear to affect the esthetic and functional results. Distraction osteogenesis is a useful alternative to traditional orthognathic surgery to treat maxillary hypoplasia. Internal distractions are attractive to patients, but are more difficult to place and can cause discomfort to patients when trying to achieve an ideal primary vector of distraction. Stereolithographic models can help with placement of the device. Changes in design of distractors may help with patient discomfort.

  12. Maxillary unicystic ameloblastoma: a case report.

    Science.gov (United States)

    Agani, Zana; Hamiti-Krasniqi, Vjosa; Recica, Jehona; Loxha, Mergime Prekazi; Kurshumliu, Fisnik; Rexhepi, Aida

    2016-10-18

    Ameloblastoma is a benign epithelial odontogenic tumor. It is often aggressive and destructive, with the capacity to attain great size, erode bone and invade adjacent structures. Unicystic ameloblastoma is a rare odontogenic lesion, with clinical, radiographic and gross features of jaw cysts. The lesion histologically shows typical ameloblastomatous epithelium lining part of the cyst cavity with or without and/or mural tumor growth. Unicystic ameloblastoma usually presents in posterior mandibular ramus region, while it is rare and atypical in posterior maxillary region. . We report a case of 16 year old Kosovar male, Albanian ethnicity, who presented with a swelling located in right maxillary region. Clinical examination revealed a painless swelling extending from the maxillary right central incisor to the maxillary right first molar tooth. Panoramic radiograph disclosed a well corticated unilocular radiolucent lesion approximately 5 × 5 cm in diameter which was in contact with the roots of the teeth present inferiorly and with the maxillary sinus superiorly. Maxillary right canine impaction was noted and unerupted lateral incisor tooth was present inside the radiolucency. Preoperative diagnosis of the lesion was made as dentigerous cyst based on the age of the patient, location of the swelling, clinical and radiographic findings, but the unicystic ameloblastoma was also taken into consideration. The patient was treated by surgical enucleation of the lesion and extraction of lateral incisor tooth which was present inside the lesion. The histopathological examination of the lesion revealed confirmed finding for unicystic ameloblastoma mural form. No recurrence was observed in 1 year follow-up. Maxillary region is considered a rare and atypical location for unicystic ameloblastoma. We emphasize the importance of differential diagnosis of an odontogenic lesion with common clinical and radiological features that will impact the treatment planning and follow up

  13. Elastic modulus and flexural strength comparisons of high-impact and traditional denture base acrylic resins

    Directory of Open Access Journals (Sweden)

    Nour M. Ajaj-ALKordy

    2014-01-01

    Conclusion: Within the limitations of this study, it can be concluded that the high-impact acrylic resin is a suitable denture base material for patients with clinical fracture of the acrylic denture.

  14. Method of Retention Control for Compromised Periodontal Bone Support Abutment of Conical Crown Retained Denture

    Directory of Open Access Journals (Sweden)

    Chau-Hsiang Wang

    2010-08-01

    Full Text Available Conical crown-retained dentures (CCRD show a higher survival rate and greater patient satisfaction than transitional removable partial dentures during long-term follow-up. However, unsustainable denture retention force on supporting abutments after initial delivery and loss retention are frequently seen in long-term follow-up of clinical cases. The main causes are insufficient information concerning denture retention designs and the retention-tolerance of the supporting abutments. Monitoring by dental technicians of the quality of dental prostheses is critical. This case report describes an optimal method for CCRD construction that determines and distributes an optimal denture retention force on the supporting abutments to allow the patient to easily remove the denture while ensuring that the CCRD remains in place during physiologic activities. Oral rehabilitation with CCRD should consider the condition of the abutment periodontal support, the interarch occlusal relationship, supplemental fatigue of the terminal abutment, and patient's estimated bite force. The effects of friction on the abutment's inner crown were based on an optimal a angle. The dental laboratory used these measurements to fabricate a CCRD using a Koni-Meter to adjust the retention of the inner crown. This method protects the abutments and reduces the wear between the inner and outer crowns. The CCRD achieved good esthetic results and physiologic functions. Periodic long-term follow-up of the patient and CCRD after initial placement is recommended.

  15. [Piezosurgery for surgically assisted rapid maxillary expansion under local anesthesia].

    Science.gov (United States)

    Sun, Hao; Li, Biao; Sun, Hao; Liu, Zhixu; Wang, Xudong

    2014-08-01

    This study evaluates piezosurgery for surgically assisted rapid maxillary expansion (SARME) under local anesthesia. SARME was performed on adults with maxillary transverse deficiency under local anesthesia with a piezosurgical device. Fourteen patients (six males and eight females) underwent lateral maxillary osteotomies, midpalatal osteotomies, and bilateral pterygomaxillary disjunction. The feelings of patients during the operation were determined through questionnaires. All patients underwent SARME in the out-patient operating room. The surgical procedures were completed under local anesthesia. All patients exhibited satisfactory tolerance. Ultrasonic bone-cutting surgery was recently introduced as a feasible alternative to the conventional tools of cranio-maxillofacial surgery for its technical characteristics of precision and safety. The device used was unique in that cutting action occurred when the tool was employed on mineralized tissues, but stoped on soft tissues. The results of the questionnaires showed that eight (57.14%) patients felt a mild sensation of ultrasonic vibration, tweleve (85.7 1%) felt mild tolerable pain and tooth soreness during surgery, and eleven (78.57%) felt little fear and hardly heard the ultrasonic sound. Preoperative and postoperative six months later measurements showed an evident effect of expansion. Piezosurgery enabled patients to undergo all the steps of SARME under local anesthesia, but more cases and longer follow-up are needed to verif ' the results.

  16. Maxillary sinus floor extension and posterior tooth inclination in adolescent patients with Class II Division 1 malocclusion treated with maxillary first molar extractions

    NARCIS (Netherlands)

    Livas, Christos; Halazonetis, Demetrios J.; Booij, Johan Willem; Pandis, Nikolaos; Tu, Yu-Kang; Katsaros, Christos

    Introduction: Our objective was to investigate potential associations between maxillary sinus floor extension and inclination of maxillary second premolars and second molars in patients with Class II Division 1 malocclusion whose orthodontic treatment included maxillary first molar extractions.

  17. Maxillary sinus floor extension and posterior tooth inclination in adolescent patients with Class II Division 1 malocclusion treated with maxillary first molar extractions

    NARCIS (Netherlands)

    Livas, C.; Halazonetis, D.J.; Booij, J.W.; Pandis, N.; Tu, Y.K.; Katsaros, C.

    2013-01-01

    INTRODUCTION: Our objective was to investigate potential associations between maxillary sinus floor extension and inclination of maxillary second premolars and second molars in patients with Class II Division 1 malocclusion whose orthodontic treatment included maxillary first molar extractions.

  18. METHODS FOR CORRECTION OF RHINOPHONIA IN PATIENTS WITH ACQUIRED MAXILLARY DEFECTS

    Directory of Open Access Journals (Sweden)

    E. G. Matyakin

    2012-01-01

    Full Text Available Speech recovery sessions were conducted in 63 patients with acquired maxillary defects. Assessment of speech quality in patients after auditory maxillary resection without a prosthestic has indicated 100 % significant rhinolalia, indistinct articulation. Prosthetic defect replacement completely corrects speech dysfunction and creates conditions for forming correct speech stereotypes. Speech therapy sessions and testing are aimed at increasing the performance of the speech apparatus and at improving the automatizaton of speaking skills. The techniques to remove nasal emission include: – articulation exercises (activation of the muscles of the lips, cheeks, tongue, pharynx, neck, and larynx; – speech respiratory gymnastics; – phonopedic (vocal exercises. The elements of rational psychotherapy have extensive applications during each session and include suggestion, an emotional exposure to correct personality disorders, as well as pedagogical elements. 

  19. OVERLAY DENTURES: A REVIEW AND REPORT OF FOUR CASES

    Directory of Open Access Journals (Sweden)

    Deeksha SHARMA

    2013-12-01

    Full Text Available Patients with ectodermal dysplasia or having under‑ gone cleft surgery with anodontia or hypodontia, hypo‑ plastic conical teeth and patients with severely worn dentition are difficult to treat because of the poor remaining tooth structure. These patients often exhibit loss of vertical dimension of occlusion and aesthetic problems and usually need complex prosthetic treatments. Financial constraints or other priorities often restrict one from choosing the most desirable treatment. The overlay removable denture is a covering prosthesis partially supported by natural teeth, tooth roots, or dental implants, providing an efficient alter‑ native of treatment. Clinical reports describe the various applications of overlay dentures.

  20. Analysis of the effects of removable dentures on the psychological status, quality of life, and masticatory function of the elderly

    Science.gov (United States)

    Dyas, R.; Nathanael, M.; Indrasari, M.; Masulili, C.; Rahardjo, T. B.; Agustin, D.; Hogervorst, E.; Kusdhany, L.

    2017-08-01

    Older age is a major risk factor for diseases of the teeth and mouth and dementia. Diseases of the teeth and mouth can lead to tooth loss. The use of removable dentures can help the elderly to replace lost teeth; therefore, dentures are expected to improve the masticatory function, quality of life, and psychological status of the elderly. The aim of this study was to analyze the effects of removable denture usage on the improvement of the psychological status, quality of life, and masticatory function of elderly people. The data was obtained from 30 respondents. The patients answered questionnaires before they used the dentures, 2 weeks after they began using dentures, and 2 months after they started wearing dentures. Four different questionnaires were used: EuroQol Five Dimensions questionnaire (EQ-5D) and Geriatric Depression Scale (GDS), to measure psychological status; a mastication questionnaire to measure masticatory function; and a validated quality of life questionnaire. Based on the results of this study, it is clear that after 2 months of denture usage, removable dentures in the elderly can significantly improve their quality of life, masticatory function, and psychological status(p<0.05).

  1. The effectiveness of adhesives on the retention of mandibular free end saddle partial dentures: An in vitro study.

    Science.gov (United States)

    Quiney, Daniel; Nishio Ayre, Wayne; Milward, Paul

    2017-07-01

    Existing in vitro methods for testing denture adhesives do not fully replicate the complex oral geometries and environment; and in vivo methods are qualitative, prone to bias and not easily reproducible. The purpose of this study was to develop a novel, quantitative and more accurate model to test the effect of adhesives on the retentive force of mandibular free end saddle partial dentures. An in vitro model was developed based on an anatomically accurate cast of a clinical case. Experimentally, the amount of adhesive was varied (0.2g-1g) and the tensile force required for displacement was measured. Different commercially available adhesives were then tested at the optimum volume using the in vitro model. A 3D finite element model of the denture was used to assess how the forces to induce denture displacement varied according to the position of the force along the saddle length. The mass of adhesive was found to significantly alter retention forces, with 0.4-0.7g being the optimum range for this particular scenario. Use of adhesives significantly improved mandibular free end saddle partial denture retention with the worst performing adhesive increasing retention nine-fold whilst the best performing adhesive increased retention twenty three-fold. The finite element model revealed that 77% more force was required to displace the denture by positioning forces towards the mesial end of the saddle compared to the distal end. An in vitro denture adhesive model was developed, which demonstrated that mass of adhesive plays a significant role in enhancing denture retention and supported the design principle of placing as few teeth as clinically necessary on the distal end of the free end saddles. Limiting the position of teeth on free end saddles to the mesial and mid portion of the saddle will reduce displacements caused by mastication. The movement of mandibular free end saddle partial dentures can be restricted with the use of denture adhesives. Altering the mass of

  2. Comparison of maxillary stability after Le Fort I osteotomy for occlusal cant correction surgery and maxillary advanced surgery.

    Science.gov (United States)

    Ueki, Koichiro; Hashiba, Yukari; Marukawa, Kohei; Yoshida, Kan; Shimizu, Chika; Nakagawa, Kiyomasa; Yamamoto, Etsuhide

    2007-07-01

    To compare postoperative maxillary stability following Le Fort I osteotomy for the correction of occlusal cant as compared with conventional Le Fort I osteotomy for maxillary advancement. The subjects were 40 Japanese adults with jaw deformities. Of these, 20 underwent a Le Fort I osteotomy and intraoral vertical ramus osteotomy (IVRO) to correct asymmetric skeletal morphology and inclined occlusal cant. The other 20 patients underwent a Le Fort I osteotomy and sagittal split ramus osteotomy (SSRO) to advance the maxilla. Lateral and posteroanterior cephalograms were taken postoperatively and assessed statistically. Thereafter, the 2 groups were followed for time-course changes. There was no significant difference between the 2 groups with regard to time-course changes during the immediate postoperative period. This suggests that maxillary stability after Le Fort I osteotomy for cant correction does not differ from that after Le Fort I osteotomy for maxillary advancement.

  3. Effect of long-term water immersion or thermal shock on mechanical properties of high-impact acrylic denture base resins.

    Science.gov (United States)

    Sasaki, Hirono; Hamanaka, Ippei; Takahashi, Yutaka; Kawaguchi, Tomohiro

    2016-01-01

    The purpose of this study was to investigate the effect of long-term water immersion or thermal shock on the mechanical properties of high-impact acrylic denture base resins. Two high-impact acrylic denture base resins were selected for the study. Specimens of each denture base material tested were fabricated according to the manufacturers' instructions (n=10). The flexural strength at the proportional limit, the elastic modulus and the impact strength of the specimens were evaluated. The flexural strength at the proportional limit of the high-impact acrylic denture base resins did not change after six months' water immersion or thermocycling 50,000 times. The elastic moduli of the high-impact acrylic denture base resins significantly increased after six months' water immersion or thermocycling 50,000 times. The impact strengths of the high-impact acrylic denture base resins significantly decreased after water immersion or thermocycling as described above.

  4. Maxillary palp glomeruli and ipsilateral projections in the antennal ...

    Indian Academy of Sciences (India)

    Maxillary palp glomeruli and ipsilateral projections in the antennal lobe of Drosophila melanogaster. K P Rajashekhar V R ... The number of glomeruli receiving the maxillary palp sensory projections tallies with the number of Drosophila olfactory receptors (seven) reported to be expressed exclusively in the maxillary palp.

  5. A new palatal distractor device for bodily movement of maxillary bones by rigid self-locking miniplates and screws system.

    Science.gov (United States)

    Cortese, Antonio; Savastano, Mauro; Cantone, Antonio; Claudio, Pier Paolo

    2013-07-01

    A new palatal distractor device for bodily movement of the maxillary bones after complete segmented Le Fort I osteotomy for 1-stage transversal distraction and tridimensional repositioning on 1 patient is presented. The new distractor has an intrinsic tridimensional rigidity also in the fixation system by self-locking miniplates and screws for better control of the 2 maxillary fragments during distraction. Le Fort I distraction and repositioning procedure in association with a bilateral sagittal split osteotomy were performed on 1 patient with complete solution of the cross-bite and class III malocclusion. Results of dental and cephalometric analysis performed before surgery (T1), after surgery and distraction time (T2), and 18 months after surgery and orthodontic appliance removal (T3) are reported. No complications were encountered using the new distractor device. Advantages of this device and technique are presented including improved rigidity of both distraction (jackscrew) and fixation (4 self-locking miniplates and screws) systems resulting in complete control of the position of the 2 maxillary fragments during distraction and surgery. In addition, this new device allows resuming palatal distraction in the event of cross-bite relapse without causing dental-related problems or the risks of screw slackening.

  6. Influence of the mechanical properties of resilient denture liners on the retention of overdenture attachments.

    Science.gov (United States)

    Kubo, Keitaro; Koike, Takashi; Ueda, Takayuki; Sakurai, Kaoru

    2018-03-15

    Information is lacking about the selection criteria for silicone resilient denture liners applied as a matrix material for attachments on overdentures. The purpose of this in vitro study was to investigate the mechanical properties of silicone resilient denture liners and their influence on the initial retention force of overdenture attachments and the reduction in retention force over time. Nine types of silicone resilient denture liner were injected and fixed to the matrix section of an experimental denture base. They were then fitted to an epoxy resin model that simulated the residual ridge with a patrix ball attachment (n=10). The retention force of the denture was measured with a digital force gauge, and the maximum force of traction (N) was regarded as the initial retention force. The retention force reduction (N) after repeated insertion and removal (n=5) was calculated by subtracting the retention force after 3348 cycles (3-year simulated insertion and removal) from the initial retention force. The intaglio of the matrix was observed with a scanning electron microscope (SEM) before and after the 3348 cycles. Four mechanical properties (hardness, strain-in-compression, tensile strength, and arithmetic mean roughness) of the resilient denture liners were measured. One-way ANOVA of the initial retention force of each lining material was performed, followed by the Scheffe test (α=.05). Pearson correlation analysis was used (α=.05) to analyze correlations of the initial retention force with the retention force reduction after insertion and removal and the mechanical properties of each material. Multiple regression analysis with the stepwise method extracted the initial retention force and the retention force reduction as dependent variables, and the resilient denture liner mechanical properties as explanatory variables (α=.05). The initial retention force of the resilient denture liners was 1.3 to 5.4 N. Multiple comparisons showed significant differences in

  7. Endodontic treatment of a maxillary second molar with developmental anomaly: a case report.

    Science.gov (United States)

    Asgary, Saeed

    2007-01-01

    Fusion is a rare occurrence in molar teeth. The purpose of this rare case presentation is to describe the nonsurgical endodontic treatment of maxillary molar. A 28-year-old patient was referred for endodontic treatment of her chronic apical abscess of right maxillary second molar. In the clinical examination, a sinus tract adjacent to involved tooth and a small crown of supernumerary tooth fused to the buccal surface of the molar at gingival margin was observed. Endodontic treatment was decided for the involved molar for functional reason. Recall examination, a year after completion of endodontic and restorative treatments, showed the tooth was clinically asymptomatic and there was no radiographic lucency around the apical region.

  8. Thoracoscopic retrieval of a "smiling" foreign body from the proximal esophagus: an impacted denture.

    Science.gov (United States)

    Palanivelu, Chinnusamy; Rangarajan, Muthukumaran; Parthasarathi, Ramakrishnan; Senthilnathan, Palaniswamy

    2008-06-01

    The esophagus is a common site for foreign bodies (FBs) because of areas of physiologic narrowing. Dentures pose special problems, especially if they are impacted. We present a case of a "smiling" foreign body in the proximal esophagus. The patient was an 80-year-old man with a history of dysphagia and swallowed dentures. Thoracoscopic removal was performed successfully as an endoscopic removal had failed and the patient had an uneventful postoperative recovery. He was discharged on the seventh postoperative day. Coins are the most commonly ingested FBs. Swallowing of dentures is found mostly in elderly patients. If endoscopic removal is not possible, then a minimally invasive surgery is an alternative. Swallowing of dentures is rare, and its thoracoscopic removal has not been reported so far. Using thoracoscopy, all the benefits of a minimally invasive surgery can be used. Minimally invasive techniques have been found to be very useful in the removal of intraluminal FBs, especially when conservative measures fail. Prevention of such incidents should be emphasized.

  9. Comparison of recognition about denture adhesive between Japanese and Indonesian dentists: A pilot study

    Directory of Open Access Journals (Sweden)

    Shinsuke Sadamori

    2005-12-01

    Full Text Available The purpose of this study was to compare cross-national differences of the recognition of denture adhesive among dentists. The design of the research was cross-cultural differences. The research was done in Japan and Indonesia. One hundred and ten dentists from Japan and Indonesia were surveyed using a questionnaire regarding knowledge/comprehension of denture adhesive (in Japanese and Indonesian versions respectively. Logistic regression model (forward stepwise method showed that it was possible to distinguish Japanese dentists from Indonesian peers with a probability of 96.0 per cent by using 4 items out of 16. For the question of "How many domestic products of denture adhesive (DA do you know?" approximately a half of the Japanese dentists answered "less than 3", whereas 93 per cent of Indonesian subjects answered "nothing". It was concluded that there were much differences in dentists' understanding and experience of denture adhesive in the clinic, between Japan and Indonesia.

  10. Modified SARME (Surgically Assisted Rapid Maxillary Expansion) in Conjunction with Orthodontic Treatment-A Case Report.

    Science.gov (United States)

    Dahiya, Sagar; Chitra, Prasad; Rao, Sadam Srinivas; Bindra, Sukhvinder

    2015-10-01

    Transverse maxillary hypoplasia or maxillary constriction in conjunction with unilateral or bilateral posterior cross bites is a common finding in cleft palate patients. These situations are also commonly encountered in adults who have not had recourse to orthodontic treatment in childhood. In adults, after ossification of the mid palatal suture is complete, the accepted means of correcting transverse skeletal discrepancies is by Surgically Assisted Rapid Maxillary Expansion (SARME). The disadvantage of this technique in the Indian scenario is reduced patient acceptance and increased treatment costs. Le Fort-I down fracture and mid palatal suture sectioning requires hospitalization and increases morbidity. A case of a 21-year-old non-cleft male who presented with Class I malocclusion with transverse skeletal discrepancy and bilateral posterior cross bites is presented. A modified SAARME technique was performed without pterygomaxillary disjunction, as an outpatient procedure. The results obtained were satisfactory and the desired amount of transverse skeletal correction was achieved. The patient was discharged the same day. The technique can be used to successfully treat a large number of patients in India with maxillary skeletal transverse problems with increased predictability, reduced costs and morbidity and higher rates of acceptance.

  11. Daya Hambat Infusum Daun Sirih Terhadap Pertumbuhan Staphylococcus aureus Yang Diisolasi Dari Denture Stomatitis ; Penelitian In Vitro.

    OpenAIRE

    bin Abdullah, Muhammad Naim

    2011-01-01

    Denture Stomatitis merupakan lesi mukosa oral berwarna merah, sakit, dan bengkak, kondisi ini karena kebiasaan jelek pada pemakai gigitiruan yang tidak mumbuka protesa pada malam hari dan jarang dibersihkan. Faktor sistemik yang mendukung terjadinya Denture Stomatitis dapat disebabkan oleh beberapa bakteri, salah satunya Staphylococcus aureus. Pencegahan Denture Stomatitis dapat dilakukan dengan sering membersihkan gigitiruan dan pemakaian obat kumur. Tujuan penelitian ini adalah untuk menguj...

  12. Endoscopic Modified Medial Maxillectomy for Fungal Ball of the Hypoplastic Maxillary Sinus With Bony Hypertrophy.

    Science.gov (United States)

    Nomura, Kazuhiro; Ikushima, Hiroyuki; Ozawa, Daiki; Shimizu, Yuichi; Arakawa, Kazuya; Suzuki, Jun; Hidaka, Hiroshi; Katori, Yukio; Ohyama, Kenji

    2018-05-01

    Sinus fungal ball is defined as noninvasive chronic rhino-sinusitis with a clump of mold in the paranasal sinuses, typically affecting the maxillary sinus. Fairly good outcomes of endoscopic surgery have been reported where the ball is removed through the antrostomy. However, the affected sinus tends to have a smaller cavity and thicker bony walls. As such, it is often challenging to maintain a window size that is sufficient to control possible recurrence. The endoscopic modified medial maxillectomy procedure was applied to a 61-year old and a 70-year old female patient with maxillary sinus fungal ball. Using this method, we created a much larger inferior meatal antrostomy without difficulty. The window provided us with an endoscopic view of the whole sinus and complete eradication of the lesion. Endoscopic modified medial maxillectomy is useful as a surgical procedure for maxillary sinus fungal ball and should be considered for better outcomes.

  13. [Percutaneous maxillary nerve block anesthesia in maxillofacial surgery].

    Science.gov (United States)

    Robiony, M; Demitri, V; Costa, F; Politi, M

    1999-01-01

    Personal experience in percutaneous maxillary nerve block anesthesia in association with transmucosal anesthesia of the sphenopalatine ganglion in oral and maxillofacial surgery, is presented. Six Caldwell-Luc, 9 anthrotomies and biopsies of maxillary sinus, 8 removals of extensive odontogenic cysts and 12 surgical maxillary expansions were performed from 1994 to 1996 at our Department. Maxillary transcutaneous nerve block in association with transmucosal anesthesia of the sphenopalatine ganglion were performed. Carbocaine without adrenaline in association with NaCO3 1/10 for maxillary nerve block anesthesia and lidocaineoprilocaine cream (EMLA) for transmucosal anesthesia were employed. Intra- and post-operative pain were evaluated by visual analogue scale in all the patients. Anesthesiological procedures revealed to be effective in all surgical interventions and postoperative analgesia allowed easier pain control. The simplicity of execution, the effective pre- and postoperative anesthesia and the absence of side effects make this procedure particularly indicated in oral and maxillofacial surgery.

  14. Root Length and Anatomy of Impacted Maxillary Canines in Patients with Unilateral Maxillary Canine Impaction

    OpenAIRE

    Mostfa Shahabi; Maryam Omidkhoda; Seyedeh Haniyeh Omidi; Seyed Hosein Hoseini Zarch

    2017-01-01

    Introduction: Canine impaction is a common occurrence. In this study, we sought to investigate the root anatomy and length of impacted canines and lateral incisor adjacent to impacted maxillary canine. Materials and Methods: In this retrospective study, three-dimensional tomographic imaging was performed on 26 patients with unilateral maxillary canine impaction. In this study, we evaluated root length and anatomy of impacted canines, in terms of resorption intensity and curvature, with Planme...

  15. Maxillary distraction complications in cleft patients.

    Science.gov (United States)

    Jeblaoui, Y; Morand, B; Brix, M; Lebeau, J; Bettega, G

    2010-06-01

    Cleft lip and palate (CLP) patients often present with a class III malocclusion in connection with a three dimensional maxillary hypoplasia. Twenty-five to 60% of these patients need maxillary advancement. Two solutions are possible: orthognathic surgery and maxillary distraction. The purpose of this study was to evaluate the complications of maxillary distraction in CLP patients. Data was collected from the records of patients treated in our surgery unit between 2000 and 2007. Among the eight patients (four male and four female), five presented with a bilateral CLP, two with a unilateral CLP, and one with a unilateral cleft lip associated to a soft palate cleft. The average age at surgery was 17 years. All underwent a Le Fort I osteotomy with a pterygomaxillary disjunction. An external distractor was used for the first two patients and an internal distractor for the six following patients. After a seven-day latency, activation was implemented at a rate of 1mm twice a day. The average period of consolidation was four months. Maxillary advancement ranged between 7 and 19mm, with an average of 12.6mm. The average follow-up was four years. Complications were noted in seven patients: one intra-operative hemorrhage, one avulsion of a tooth anchored at the pterygoid process during osteotomy, three cases of device dysfunction, two cases of significant pain during activation, one loosening of the orthodontic arch in an external system, two cases of labial ulceration, and one maxillary sinusitis due to migration of a wisdom tooth. Complications of maxillary distraction in CLP patients were very frequent. Most were related to the device and did not interfere with the final result. This must be taken into account when indicating distraction and choosing the device. Two types of complications can occur during distraction: those related to the osteotomy and those related to the device. The complications related to the osteotomy are linked to the cicatricial ground of previous

  16. [Maxillary distraction complications in cleft patients].

    Science.gov (United States)

    Jeblaoui, Y; Morand, B; Brix, M; Lebeau, J; Bettega, G

    2008-09-01

    Cleft lip and palate (CLP) patients often present with a class III malocclusion in connection with a three dimensional maxillary hypoplasia. Twenty-five to 60% of these patients require a maxillary advancement. Two solutions are possible: orthognathic surgery and maxillary distraction. The purpose of this study was to evaluate the complications of the maxillary distraction in CLP patients. Data was collected from the records of patients treated at our Surgery Unit between 2000 and 2007. Among the eight patients (four male and four female), five presented a bilateral CLP, two a unilateral CLP and one a unilateral cleft lip associated to a soft palate cleft. The average age at surgery was 17 years old. All had a Le Fort I osteotomy with a pterygomaxillary disjunction. The first two patients had external distractors and the six following internal ones. After a seven-day latency, activation was led to the rate of 1mm per day twice. The period of consolidation was four months on average. The maxillary advancement varied between 7 and 19 mm with an average of 12.6mm. The average follow-up was four years. We encountered difficulties and/or complications in seven patients: one intraoperatively haemorrhage, one avulsion of a tooth fixed at the pterygoid process during the osteotomy, three device failures, two cases of significant pains during activation, one dissociation of the dental anchorage of an external system, two labial ulcerations and one maxillary sinusitis by migration of the 18. Difficulties of maxillary distraction in CLP patients are very frequent. The majority is related to the distractors and did not interfere with the final result. But this frequency must be taken into account in the indication and in the choice of the material. Two types of complications can occur during distraction: those related to the osteotomy and those related to the material. The complications related to the osteotomy are in connection with the cicatricial ground of the CLP. They are

  17. Le Fort I Maxillary Advancement Using Distraction Osteogenesis

    OpenAIRE

    Combs, Patrick D.; Harshbarger, Raymond J.

    2014-01-01

    Treatment of maxillary hypoplasia has traditionally involved conventional Le Fort I osteotomies and advancement. Advancements of greater than 10 mm risk significant relapse. This risk is greater in the cleft lip and palate population, whose anatomy and soft tissue scarring from prior procedures contributes to instability of conventional maxillary advancement. Le Fort I advancement with distraction osteogenesis has emerged as viable, stable treatment modality correction of severe maxillary hyp...

  18. Creating natural-looking removable prostheses: combining art and science to imitate nature.

    Science.gov (United States)

    Patras, Michael; Kourtis, Stefanos; Sykaras, Nikitas

    2012-06-01

    Patient awareness of dental appearance has increased, resulting in more demanding esthetic requests. There is also strong evidence that increased esthetics is highly significant for complete denture acceptance and success. Taking notice of patients' perceptions of natural appearance and esthetics, the clinician can incorporate their preferences in the construction of individualized dentures that will be harmonized with their facial characteristics. Despite the evolution of materials and techniques, the vast majority of dentures still fail to look natural. Thus, producing prostheses that defy detection and successfully restore the appearance of edentulous patients remains a challenge for the clinician. This paper presents a clinical case where immediate loading of implants supporting a mandibular overdenture was combined with an opposing conventional maxillary denture to satisfy the high functional and esthetic demands of the patient. It also emphasizes the individualized esthetic performance through customization during their fabrication while taking into consideration the various clinical parameters affecting rehabilitation of the edentulous jaw. Implant-retained overdentures can significantly improve the patients' function. The esthetic performance of these restorations however, may not be satisfying the patients' expectations and demands. Customizing the artificial gingival areas and individual staining of the prefabricated acrylic teeth may improve the esthetic performance creating natural-looking removable prostheses. © 2011 Wiley Periodicals, Inc.

  19. A Survey of Removable Partial Denture (RPD) Retentive Elements in Relation to the Type of Edentulism and Abutment Teeth Found in Commercial Laboratories, Athens, Greece

    Science.gov (United States)

    Sotiriou, Michael; Zissis, Alcibiades

    2014-01-01

    Objective The aim of this survey was to record removable partial denture (RPD) retentive elements and abutment teeth in partially edentulous patients, identified in commercial laboratories in Athens, Greece. Material and Methods 628 master casts with the corresponding cast metal frameworks used in the construction of RPDs were evaluated. Casts were photographed to identify the number and position of existing teeth, the partial edentulism class and the retentive elements. Prevalence tables and the x2 test were used for the statistical analysis of the collected data (α=.05). Results There were 276 maxillary (43.9%) and 352 (56.1%) mandibular casts. Maxillary edentulism entailed almost a total absence of right third molars in 96.7% and left third molars 96.0% of casts, with lower rates for the first and second molars. Edentulism in the posterior mandible presented a similar pattern. The most profound findings concerning retentive elements were: 91.9% of the retainers used were clasps and the remaining 8.1% were attachments. Of the clasps used, 48.9% were of the Roach Τ type, a finding more common in Kennedy Class I as compared to other Kennedy Classes (p<0.01). The circumferential clasps accounted for 19.3% of the total clasps used, and it was less frequently presented (8.8%) in Kennedy I Classes (p<0.01). Conclusions Roach clasps were used in the majority of cases whereas RPI clasps and attachments were rarely used. PMID:27688367

  20. Le Fort I Maxillary Advancement Using Distraction Osteogenesis

    Science.gov (United States)

    Combs, Patrick D.; Harshbarger, Raymond J.

    2014-01-01

    Treatment of maxillary hypoplasia has traditionally involved conventional Le Fort I osteotomies and advancement. Advancements of greater than 10 mm risk significant relapse. This risk is greater in the cleft lip and palate population, whose anatomy and soft tissue scarring from prior procedures contributes to instability of conventional maxillary advancement. Le Fort I advancement with distraction osteogenesis has emerged as viable, stable treatment modality correction of severe maxillary hypoplasia in cleft, syndromic, and noncleft patients. In this article, the authors provide a review of current data and recommendations concerning Le Fort I advancement with distraction osteogenesis. In addition, they outline their technique for treating severe maxillary hypoplasia with distraction osteogenesis using internal devices. PMID:25383054