WorldWideScience

Sample records for making spectrophotometric measurements

  1. Spectrophotometric measurement of calcium carbonate saturation states in seawater.

    Easley, Regina A; Patsavas, Mark C; Byrne, Robert H; Liu, Xuewu; Feely, Richard A; Mathis, Jeremy T

    2013-02-05

    Measurements of ocean pH and carbonate ion concentrations in the North Pacific and Arctic Oceans were used to determine calcium carbonate saturation states (Ω(CaCO(3))) from spectrophotometric methods alone. Total carbonate ion concentrations, [CO(3)(2-)](T), were for the first time at sea directly measured using Pb(II) UV absorbance spectra. The basis of the method is given by the following: [formula see text] where (CO(3))β(1) is the PbCO(3)(0) formation constant, e(i) are molar absorptivity ratios, and R = (250)A/(234)A (ratio of absorbances measured at 250 and 234 nm). On the basis of shipboard and laboratory Pb(II) data and complementary carbon-system measurements, the experimental parameters were determined to be (25 °C) the following: [formula see text]. The resulting mean difference between the shipboard spectrophotometric and conventional determinations of [CO(3)(2-)](T) was ±2.03 μmol kg(-1). The shipboard analytical precision of the Pb(II) method was ∼1.71 μmol kg(-1) (2.28%). Spectrophotometric [CO(3)(2-)](T) and pH(T) were then combined to calculate Ω(CaCO(3)). For the case of aragonite, 95% of the spectrophotometric aragonite saturation states (Ω(Aspec)) were within ±0.06 of the conventionally calculated values (Ω(Acalc)) when 0.5 ≤ Ω(A) ≤ 2.0. When Ω(A) > 2.0, 95% of the Ω(Aspec) values were within ±0.18 of Ω(Acalc). Our shipboard experience indicates that spectrophotometric determinations of [CO(3)(2-)](T) and Ω(CaCO(3)) are straightforward, fast, and precise. The method yields high-quality measurements of two important, rapidly changing aspects of ocean chemistry and offers capabilities suitable for long-term automated in situ monitoring.

  2. In situ spectrophotometric measurement of dissolved inorganic carbon in seawater

    Liua, Xuewu; Byrne, Robert H.; Adornato, Lori; Yates, Kimberly K.; Kaltenbacher, Eric; Ding, Xiaoling; Yang, Bo

    2013-01-01

    Autonomous in situ sensors are needed to document the effects of today’s rapid ocean uptake of atmospheric carbon dioxide (e.g., ocean acidification). General environmental conditions (e.g., biofouling, turbidity) and carbon-specific conditions (e.g., wide diel variations) present significant challenges to acquiring long-term measurements of dissolved inorganic carbon (DIC) with satisfactory accuracy and resolution. SEAS-DIC is a new in situ instrument designed to provide calibrated, high-frequency, long-term measurements of DIC in marine and fresh waters. Sample water is first acidified to convert all DIC to carbon dioxide (CO2). The sample and a known reagent solution are then equilibrated across a gas-permeable membrane. Spectrophotometric measurement of reagent pH can thereby determine the sample DIC over a wide dynamic range, with inherent calibration provided by the pH indicator’s molecular characteristics. Field trials indicate that SEAS-DIC performs well in biofouling and turbid waters, with a DIC accuracy and precision of ∼2 μmol kg–1 and a measurement rate of approximately once per minute. The acidic reagent protects the sensor cell from biofouling, and the gas-permeable membrane excludes particulates from the optical path. This instrument, the first spectrophotometric system capable of automated in situ DIC measurements, positions DIC to become a key parameter for in situ CO2-system characterizations.

  3. ATPase Activity Measurements by an Enzyme-Coupled Spectrophotometric Assay.

    Sehgal, Pankaj; Olesen, Claus; Møller, Jesper V

    2016-01-01

    Enzymatic coupled assays are usually based on the spectrophotometric registration of changes in NADH/NAD(+) or NADPH/NADP(+) absorption at 340 nm accompanying the oxidation/reduction of reactants that by dehydrogenases and other helper enzymes are linked to the activity of the enzymatic reaction under study. The present NADH-ATP-coupled assay for ATPase activity is a seemingly somewhat complicated procedure, but in practice adaptation to performance is easily acquired. It is a more safe and elegant method than colorimetric methods, but not suitable for handling large number of samples, and also presupposes that the activity of the helper enzymes is not severely affected by the chemical environment of the sample in which it is tested.

  4. Human perception of dental porcelain translucency correlated to spectrophotometric measurements.

    Liu, Min-Chieh; Aquilino, Steven A; Lund, Peter S; Vargas, Marcos A; Diaz-Arnold, Ana M; Gratton, David G; Qian, Fang

    2010-04-01

    This study evaluated the relationship between instrumental measurements and subjective visual assessment of differences in dental porcelain translucency. Unshaded feldspathic porcelain was used with controlled amounts of tin oxide to create two groups of 12-mm diameter disks with incremental changes in opacity. Contrast ratio (CR = Yb/Yw) was determined with a spectrophotometer, and used as a measure of porcelain translucency (Group A = 0.20 to 0.40; Group B = 0.6-0.8). Within each group, there were 14 specimens with 11 CRs. Three observer groups (first year dental students, residents, faculty with >10 years of shade matching experience) were recruited to assess the translucency between porcelain disks under two lighting conditions (reflected light, transmitted light). Each subject's ability to distinguish between specimens of differing translucency was determined. Descriptive statistics and three-way ANOVA followed by a post-hoc Tukey-Kramer test were used to evaluate the translucency perception threshold (TPT) of subjects (alpha= 0.05). The overall mean TPT (DeltaC) was 0.07, while 50% of the subjects could perceive a 0.06 CR difference between porcelain specimens. Three-way ANOVA revealed a significant difference in translucency perception among the observer groups (p or =10 years) significantly improved the ability to perceive differences in translucency; however, neither the viewing condition nor porcelain opacity affected the perceived translucency threshold.

  5. Spectrophotometric high-precision seawater pH determination for use in underway measuring systems

    S. Aßmann

    2011-10-01

    Full Text Available Autonomous sensors are required for a comprehensive documentation of the changes in the marine carbon system and thus to differentiate between its natural variability and anthropogenic impacts. Spectrophotometric determination of pH – a key variable of the seawater carbon system – is particularly suited to achieve precise and drift-free measurements. However, available spectrophotometric instruments are not suitable for integration into automated measurement systems (e.g. FerryBox since they do not meet the major requirements of reliability, stability, robustness and moderate cost. Here we report on the development and testing of a~new indicator-based pH sensor that meets all of these requirements. This sensor can withstand the rough conditions during long-term deployments on ships of opportunity and is applicable to the open ocean as well as to coastal waters with a complex matrix and highly variable conditions. The sensor uses a high resolution CCD spectrometer as detector connected via optical fibers to a custom-made cuvette designed to reduce the impact of air bubbles. The sample temperature can be precisely adjusted (25 °C ± 0.006 °C using computer-controlled power supplies and Peltier elements thus avoiding the widely used water bath. The overall setup achieves a measurement frequency of 1 min−1 with a precision of ±0.0007 pH units, an average offset of +0.0005 pH units to a reference system, and an offset of +0.0081 pH units to a certified standard buffer. Application of this sensor allows monitoring of seawater pH in autonomous underway systems, providing a key variable for characterization and understanding of the marine carbon system.

  6. Measurement of peroxisomal enzyme activities in the liver of brown trout (Salmo trutta, using spectrophotometric methods

    Resende Albina D

    2003-03-01

    Full Text Available Abstract Background This study was aimed primarily at testing in the liver of brown trout (Salmo trutta spectrophotometric methods previously used to measure the activities of catalase and hydrogen peroxide producing oxidases in mammals. To evaluate the influence of temperature on the activities of those peroxisomal enzymes was the second objective. A third goal of this work was the study of enzyme distribution in crude cell fractions of brown trout liver. Results The assays revealed a linear increase in the activity of all peroxisomal enzymes as the temperature rose from 10° to 37°C. However, while the activities of hydrogen peroxide producing oxidases were strongly influenced by temperature, catalase activity was only slightly affected. A crude fraction enriched with peroxisomes was obtained by differential centrifugation of liver homogenates, and the contamination by other organelles was evaluated by the activities of marker enzymes for mitochondria (succinate dehydrogenase, lysosomes (aryl sulphatase and microsomes (NADPH cytochrome c reductase. For peroxisomal enzymes, the activities per mg of protein (specific activity in liver homogenates were strongly correlated with the activities per g of liver and with the total activities per liver. These correlations were not obtained with crude peroxisomal fractions. Conclusions The spectrophotometric protocols originally used to quantify the activity of mammalian peroxisomal enzymes can be successfully applied to the study of those enzymes in brown trout. Because the activity of all studied peroxisomal enzymes rose in a linear mode with temperature, their activities can be correctly measured between 10° and 37°C. Probably due to contamination by other organelles and losses of soluble matrix enzymes during homogenisation, enzyme activities in crude peroxisomal fractions do not correlate with the activities in liver homogenates. Thus, total homogenates will be used in future seasonal and

  7. Quantitative HPLC Analysis of Rosmarinic Acid in Extracts of "Melissa officinalis" and Spectrophotometric Measurement of Their Antioxidant Activities

    Canelas, Vera; da Costa, Cristina Teixeira

    2007-01-01

    The students prepare tea samples using different quantities of lemon balm leaves ("Melissa officinalis") and measure the rosmarinic acid contents by an HPLC-DAD method. The antioxidant properties of the tea samples are evaluated by a spectrophotometric method using a radical-scavenging assay with DPPH. (2,2-diphenyl-1-picrylhydrazyl). Finally the…

  8. Determination of DPPH Radical Oxidation Caused by Methanolic Extracts of Some Microalgal Species by Linear Regression Analysis of Spectrophotometric Measurements

    Ulf-Peter Hansen

    2007-10-01

    Full Text Available The demonstrated modified spectrophotometric method makes use of the 2,2-diphenyl-1-picrylhydrazyl (DPPH radical and its specific absorbance properties. Theabsorbance decreases when the radical is reduced by antioxidants. In contrast to otherinvestigations, the absorbance was measured at a wavelength of 550 nm. This wavelengthenabled the measurements of the stable free DPPH radical without interference frommicroalgal pigments. This approach was applied to methanolic microalgae extracts for twodifferent DPPH concentrations. The changes in absorbance measured vs. the concentrationof the methanolic extract resulted in curves with a linear decrease ending in a saturationregion. Linear regression analysis of the linear part of DPPH reduction versus extractconcentration enabled the determination of the microalgae’s methanolic extractsantioxidative potentials which was independent to the employed DPPH concentrations. Theresulting slopes showed significant differences (6 - 34 μmol DPPH g-1 extractconcentration between the single different species of microalgae (Anabaena sp.,Isochrysis galbana, Phaeodactylum tricornutum, Porphyridium purpureum, Synechocystissp. PCC6803 in their ability to reduce the DPPH radical. The independency of the signal on the DPPH concentration is a valuable advantage over the determination of the EC50 value.

  9. Spectrophotometric method for quantitative measuring essential oil in aromatic water and distillate with rose smell

    Semenova, E; Moiseeva, I; Presnyakova, V; Goncharov, D; Goncharov, M; Presnyakova, E; Presnyakov, S; Kolesnikova, S

    2017-01-01

    In this connection, we improved the express methods of determining the mixture of volatile aromatic substances by the spectrophotometry of aromatic water and steam distillate of essential oil raw materials (traditional or biotechnological with rose smell). Direct spectrophotometry of distillation water is impossible because it is a colloid of liquid oil and law is not observed. Therefore, it is necessary to dissolve 1 ml of distillate in ethanol in the ratio 1:4, in this case we take real solution with no lipophilic fall-out on the walls of cuvette, also the light absorption law is observed. There are stable maximums in spectrums of studied oils. Optical density of these maximums is a result of summary absorption of terpenoid components (aromatic and monoterpene alcohols, its ethers). Optical density of tested and standard solutions is measured in appropriate wavelengths. Spectrophotometric method of determination of essential oil quantity in aromatic water with rose smell differs with high sensitivity (10 -5 -10 -6 gmol/l) and allows to determine oil concentration from 0,900 to 0,008 mg with an error less than 1%. At that, 1 ml is enough for analysis. It’s expedient to apply this method while operating with small quantity of water distillate in biochemical and biotechnological researches and also as express control for extraction and hydrodistillation of essential oil raw material (rose petals and flowers from different origin, eremothecium cultural liquid etc.). (paper)

  10. Determination of total antioxidant capacity by a new spectrophotometric method based on Ce(IV) reducing capacity measurement.

    Ozyurt, Dilek; Demirata, Birsen; Apak, Resat

    2007-02-28

    Dietary antioxidants widely found in fruits and vegetables may serve the task of reducing oxidative damage in humans induced by free radicals and reactive oxygen species under 'oxidative stress' conditions. The aim of this work is to develop a simple, low-cost, sensitive, and diversely applicable indirect spectrophotometric method for the determination of total antioxidant capacity of several plants. The method is based on the oxidation of antioxidants with cerium(IV) sulfate in dilute sulfuric acid at room temperature. The Ce(IV) reducing capacity of the sample is measured under carefully adjusted conditions of oxidant concentration and pH such that only antioxidants and not other organic compounds would be oxidized. The spectrophotometric determination of the remaining Ce(IV) was performed after completion of reaction with antioxidants. Quercetin and gallic acid were used as standards for flavonoids and phenolic acids, respectively, and results of antioxidant measurements were reported as trolox equivalents. The developed procedure was successfully applied to the assay of total antioxidant capacity due to simple compounds such as trolox, quercetin, gallic acid, ascorbic acid, catechin, naringin, naringenin, caffeic acid, chlorogenic acid, ferulic acid, and p-coumaric acid, and due to phenolic acids and flavonoids in the arieal parts of nettle (Urtica Dioica L.). Blank correction of significantly absorbing plant extracts at 320nm could be made with the aid of spectrophotometric titration. Plant selection was made in respect to high antioxidant content, and extraction was made with water. The proposed method was reproducible, and the trolox equivalent antioxidant capacities (TEAC coefficients) of the tested antioxidant compounds were correlated to those found by reference methods such as ABTS and CUPRAC. Since the TEAC coefficients found with the proposed method of naringin-naringenin and rutin-catechin pairs were close to each other, this Ce(IV)-based assay

  11. The kinetics of colour change in textiles and fibres treated with detergent solutions Part II - Spectrophotometric measurements.

    Was-Gubala, Jolanta; Grzesiak, Edyta

    2010-06-01

    The aim of this study was to assess colour variations that occur in several types of textiles and their constituent fibres, resulting from the long-term influence of various laundry detergents. A 14-day experiment was conducted using blue, red and grey/black cotton, wool, acrylic and polyester textiles. The spectrophotometric measurement of colour changes in fabric samples and test solutions, as well as the microspectrophotometric analysis of colour changes in single fibres were described. An evaluation of the observed colour changes from a forensic fibre analysis expert's point of view, as well as that of an average user/consumer of the textiles and laundry detergents is also provided. Copyright 2009 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Single peak parameters technique for simultaneous measurements: Spectrophotometric sequential injection determination of Fe(II) and Fe(III).

    Kozak, J; Paluch, J; Węgrzecka, A; Kozak, M; Wieczorek, M; Kochana, J; Kościelniak, P

    2016-02-01

    Spectrophotometric sequential injection system (SI) is proposed to automate the method of simultaneous determination of Fe(II) and Fe(III) on the basis of parameters of a single peak. In the developed SI system, sample and mixture of reagents (1,10-phenanthroline and sulfosalicylic acid) are introduced into a vessel, where in an acid environment (pH≅3) appropriate compounds of Fe(II) and Fe(III) with 1,10-phenanthroline and sulfosalicylic acid are formed, respectively. Then, in turn, air, sample, EDTA and sample again, are introduced into a holding coil. After the flow reversal, a segment of air is removed from the system by an additional valve and as EDTA replaces sulfosalicylic acid forming a more stable colorless compound with Fe(III), a complex signal is registered. Measurements are performed at wavelength 530 nm. The absorbance measured at minimum of the negative peak and the area or the absorbance measured at maximum of the signal can be used as measures corresponding to Fe(II) and Fe(III) concentrations, respectively. The time of the peak registration is about 2 min. Two-component calibration has been applied to analysis. Fe(II) and Fe(III) can be determined within the concentration ranges of 0.04-4.00 and 0.1-5.00 mg L(-1), with precision less than 2.8% and 1.7% (RSD), respectively and accuracy better than 7% (RE). The detection limit is 0.04 and 0.09 mg L(-1) for Fe(II) and Fe(III), respectively. The method was applied to analysis of artesian water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Extraction spectrophotometric analyzer

    Batik, J.; Vitha, F.

    1985-01-01

    Automation is discussed of extraction spectrophotometric determination of uranium in a solution. Uranium is extracted from accompanying elements in an HCl medium with a solution of tributyl phosphate in benzene. The determination is performed by measuring absorbance at 655 nm in a single-phase ethanol-water-benzene-tributyl phosphate medium. The design is described of an analyzer consisting of an analytical unit and a control unit. The analyzer performance promises increased productivity of labour, improved operating and hygiene conditions, and mainly more accurate results of analyses. (J.C.)

  14. The measurement of acetanilide in plasma by spectrophotometric and selected ion monitoring methods.

    Baty, J D; Playfer, J; Evans, D A; Lamb, J

    1977-08-01

    Plasma samples from volunteers who had received an oral dose of acetanilide have been analysed by gas chromatography mass spectrometry and ultraviolet absorption techniques. The gas chromatography mass spectrometry method involved extraction of the plasma and analysis of the acetanilide using selected ion monitoring with a deuterated internal standard. In the ultraviolet method the plasma was hydrolysed with acid to convert the acetanilide to aniline, and this compound was diazotized and coupled with N-1-naphthylethylene-diamine. The absorbance of the resulting complex was read at 550 nm. Acetanilide levels in plasma determined by the selected ion monitoring method were significantly lower than those measured by spectrophotometry. Pharmacokinetic data calculated from the results obtained using these two assays are very different and illustrate the need for an accurate and specific method of analysis. The major metabolites of acetanilide are shown not to interfere with these assays and the results suggest the possible presence of a new metabolite of acetanilide.

  15. Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters

    Gentle, Brady S.; Ellis, Peter S.; Grace, Michael R. [Water Studies Centre, School of Chemistry, Monash University, Victoria 3800 (Australia); McKelvie, Ian D., E-mail: iandm@unimelb.edu.au [School of Chemistry, University of Melbourne, Victoria 3010 (Australia); School of Geography, Earth and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom)

    2011-10-17

    Highlights: {yields} Second derivative UV spectrophotometry has been used to determine nitrate and total N using flow analysis techniques. {yields} A simple flow system with a single-reflection flow-through cell was used for the UV measurement of nitrate. {yields} Total N was determined after on-line UV photooxidation with alkaline peroxodisulfate. {yields} Analyses carried out using the developed flow systems show a high degree of agreement with comparative analyses. {yields} This method requires no colorimetric reagents and eliminates the requirement for a toxic cadmium reduction column. - Abstract: Second derivative ultra-violet spectrophotometric methods are described for the measurement of nitrate and total nitrogen in freshwaters using flow analysis techniques. A simple flow system consisting of a peristaltic pump and a single-reflection flow-through cell was used for the measurement of nitrate. Quantification of total nitrogen using alkaline peroxodisulfate photo-digestion was achieved by incorporating an ultra-violet photo-reactor, a hollow-fibre filter and a debubbler into the flow system. The nitrate system featured a limit of detection of 0.04 mg N L{sup -1}, 0.4%RSD (1 mg N L{sup -1} as nitrate, n = 10), a coefficient of determination (R{sup 2}) of 0.9995 over the calibration range 0.0-2.0 mg N L{sup -1}, and a data acquisition time of 1.5 s per spectrum. The total nitrogen system featured a limit of detection of 0.05 mg N L{sup -1}, 1%RSD (1 mg N L{sup -1} as ammonium chloride, n = 10), a coefficient of determination of 0.9989 over the calibration range 0.0-2.0 mg N L{sup -1}, and a throughput of 5 sample h{sup -1} measured in triplicate. Digestions of five model nitrogen compounds returned recoveries of >88%. Determinations carried out using the developed systems show a high degree of agreement with data obtained using reference methods. These methods require no colorimetric reagents and eliminate the requirement for a toxic cadmium reduction column

  16. Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters

    Gentle, Brady S.; Ellis, Peter S.; Grace, Michael R.; McKelvie, Ian D.

    2011-01-01

    Highlights: → Second derivative UV spectrophotometry has been used to determine nitrate and total N using flow analysis techniques. → A simple flow system with a single-reflection flow-through cell was used for the UV measurement of nitrate. → Total N was determined after on-line UV photooxidation with alkaline peroxodisulfate. → Analyses carried out using the developed flow systems show a high degree of agreement with comparative analyses. → This method requires no colorimetric reagents and eliminates the requirement for a toxic cadmium reduction column. - Abstract: Second derivative ultra-violet spectrophotometric methods are described for the measurement of nitrate and total nitrogen in freshwaters using flow analysis techniques. A simple flow system consisting of a peristaltic pump and a single-reflection flow-through cell was used for the measurement of nitrate. Quantification of total nitrogen using alkaline peroxodisulfate photo-digestion was achieved by incorporating an ultra-violet photo-reactor, a hollow-fibre filter and a debubbler into the flow system. The nitrate system featured a limit of detection of 0.04 mg N L -1 , 0.4%RSD (1 mg N L -1 as nitrate, n = 10), a coefficient of determination (R 2 ) of 0.9995 over the calibration range 0.0-2.0 mg N L -1 , and a data acquisition time of 1.5 s per spectrum. The total nitrogen system featured a limit of detection of 0.05 mg N L -1 , 1%RSD (1 mg N L -1 as ammonium chloride, n = 10), a coefficient of determination of 0.9989 over the calibration range 0.0-2.0 mg N L -1 , and a throughput of 5 sample h -1 measured in triplicate. Digestions of five model nitrogen compounds returned recoveries of >88%. Determinations carried out using the developed systems show a high degree of agreement with data obtained using reference methods. These methods require no colorimetric reagents and eliminate the requirement for a toxic cadmium reduction column. The overlap of chloride and nitrate spectra in seawater is

  17. Measurement of trimethylamine concentration and evaluation of pig meat natural quality by a spectrophotometric method

    Mohammod Abdul HAMID,Xi WANG,Xiangdong DING,Chuduan WANG,Xingbo ZHAO

    2014-09-01

    Full Text Available Pig meat off-flavor is attributed to trimethylamine (TMA concentration, and it is considered as the precursor of the fishy off-flavor problems. In this study, TMA concentrations in pig meat were determined, and the interactions with breed and gender effects were discussed. In addition, the TMA threshold for meat off-flavor and pig meat natural quality was measured in relation to meat storage and movement, and the influential factors including the pig breed and storage time were discussed. The results indicated positive effects on the precursor of the fishy off-flavor and the TMA threshold. Native breeds were found to have lower TMA concentrations than European breeds (P<0.01, and females and castrated males had significantly lower TMA concentration than males (P<0.01, The threshold concentration of TMA when meat was classed as off-flavored was 25 μg·g-1, and this occurred after 35–38 h of storage. The natural qualities, such as appearance, flavor, color and overall acceptable scores declined significantly after 4 days in storage (P<0.01. It is concluded that pig meat off-flavor, breed and gender were essential factors affecting flavor for meat breeding programs, and storage time is important for pig meat natural quality.

  18. Measurement of Capsaicinoids in Chiltepin Hot Pepper: A Comparison Study between Spectrophotometric Method and High Performance Liquid Chromatography Analysis

    Alberto González-Zamora

    2015-01-01

    Full Text Available Direct spectrophotometric determination of capsaicinoids content in Chiltepin pepper was investigated as a possible alternative to HPLC analysis. Capsaicinoids were extracted from Chiltepin in red ripe and green fruit with acetonitrile and evaluated quantitatively using the HPLC method with capsaicin and dihydrocapsaicin standards. Three samples of different treatment were analyzed for their capsaicinoids content successfully by these methods. HPLC-DAD revealed that capsaicin, dihydrocapsaicin, and nordihydrocapsaicin comprised up to 98% of total capsaicinoids detected. The absorbance of the diluted samples was read on a spectrophotometer at 215–300 nm and monitored at 280 nm. We report herein the comparison between traditional UV assays and HPLC-DAD methods for the determination of the molar absorptivity coefficient of capsaicin (ε280=3,410 and ε280=3,720 M−1 cm−1 and dihydrocapsaicin (ε280=4,175 and ε280=4,350 M−1 cm−1, respectively. Statistical comparisons were performed using the regression analyses (ordinary linear regression and Deming regression and Bland-Altman analysis. Comparative data for pungency was determined spectrophotometrically and by HPLC on samples ranging from 29.55 to 129 mg/g with a correlation of 0.91. These results indicate that the two methods significantly agree. The described spectrophotometric method can be routinely used for total capsaicinoids analysis and quality control in agricultural and pharmaceutical analysis.

  19. CATALYTIC KINETIC SPECTROPHOTOMETRIC DETERMINATION ...

    Preferred Customer

    acetylchlorophosphonazo(CPApA) by hydrogen peroxide in 0.10 M phosphoric acid. A novel catalytic kinetic-spectrophotometric method is proposed for the determination of copper based on this principle. Copper(II) can be determined spectrophotometrically ...

  20. Spectrophotometric analysis of irradiated spices

    Josimovic, L; Cudina, I

    1987-01-01

    Seven different spices (thyme, cinnamon, coriander, caraway, pimento, paprika, black pepper) were treated by gamma radiation at an absorbed dose of 10 kGy, and the effect on chemical quality was determined. The effects of this dose were assessed by spectrophotometric analysis of some water-soluble constituents of spices (carbohydrates; carbonyl compounds) and on the content of water-insoluble steam-volatile oils. The colour of paprika and the content of piperine in pepper held in different packaging materials were measured in unirradiated and irradiated samples as a function of storage time. In all cases irradiation does not bring about any distinct qualitative or quantitative chemical changes based on spectrophotometric analysis of spice extracts.

  1. Spectrophotometric Analysis of Caffeine

    Showkat Ahmad Bhawani

    2015-01-01

    Full Text Available The nature of caffeine reveals that it is a bitter white crystalline alkaloid. It is a common ingredient in a variety of drinks (soft and energy drinks and is also used in combination with various medicines. In order to maintain the optimum level of caffeine, various spectrophotometric methods have been developed. The monitoring of caffeine is very important aspect because of its consumption in higher doses that can lead to various physiological disorders. This paper incorporates various spectrophotometric methods used in the analysis of caffeine in various environmental samples such as pharmaceuticals, soft and energy drinks, tea, and coffee. A range of spectrophotometric methodologies including chemometric techniques and derivatization of spectra have been used to analyse the caffeine.

  2. Spectrophotometric Determination of Ezetimibe

    P. Baby Sudha Lakshmi

    2010-01-01

    Full Text Available Two simple, sensitive, selective and accurate spectro-photometric methods (Method A and Method B for the determination of eztimibe in bulk drug and pharmaceutical formulations (tablets have been described. Method A and B are based on the redox/complex formation reaction of drug with 1,10-phenanthroline and hexacyano-ferrate(III in presence of ferric chloride to form coloured chromogens exhibiting λmax at 510 and 740 nm respectively. The results of analysis for the two methods have been validated statistically and by recovery studies. The results are compared with those obtained using UV spectrophotometric method in alcohol at 231.7 nm.

  3. Spectrophotometric determination of copper with ascorbic acid

    Majeed, A; Mustafa, M M; Asma, R N; Sareecha, N [Islamia Univ., Bahawalpur (Pakistan). Chemistry Dept.

    1996-06-01

    Copper has been determined spectrophotometrically by using ascorbic acid as a chromagenic reagent. The complex formed in basic medium is measured for its absorbance at 340 n.m. Interference for 23 cations and 9 anions has also been checked. Effect of pH, time, temperature, ammonia, reagent concentration and interferents has been report. (author).

  4. Development of an indirect spectrophotometric method for ...

    A simple and rapid indirect spectrophotometric method for determination of ... of the colored product was measured at 405 nm and pH 3 against a reagent blank. ... The limit of detection and quantification were found to be 0.20±0.03 and ...

  5. Spectrophotometric Determination of Nitrate in Vegetables Using ...

    DR. MIKE HORSFALL

    ABSTRACT: A rapid and sensitive spectrophotometric method for the determination of nitrate in vegetables is described. The method is based on the measurement of the absorbance of yellow sodium nitrophenoxide formed via the reaction of phenol with the vegetable-based nitrate in presence of sulphuric acid.

  6. Spectrophotometric determination of copper with ascorbic acid

    Majeed, A.; Mustafa, M.M.; Asma, R.N.; Sareecha, N.

    1996-01-01

    Copper has been determined spectrophotometrically by using ascorbic acid as a chromagenic reagent. The complex formed in basic medium is measured for its absorbance at 340 n.m. Interference for 23 cations and 9 anions has also been checked. Effect of pH, time, temperature, ammonia, reagent concentration and interferents has been report. (author)

  7. Measurement, monitoring, and verification: make it work!

    Coeli M. Hoover

    2011-01-01

    The capacity of forests to absorb and store carbon is certainly, as the authors note, an important tool in the greenhouse gas mitigation toolbox. Our understanding of what elements can make forest carbon offset projects successful has grown a great deal over time, as the global community has come to understand that forest degradation and conversion are the result of a...

  8. Spectrophotometric calibration system for DECam

    Rheault, J.-P.; DePoy, D. L.; Marshall, J. L.; Prochaska, T.; Allen, R.; Wise, J.; Martin, E.; Williams, P.

    2012-09-01

    We describe a spectrophotometric calibration system that is being implemented as part of the DES DECam project at the Blanco 4 meter at CTIO. Our calibration system uses a 1nm wide tunable source to measure the instrumental response function of the telescope optics and detector from 300nm up to 1100nm. This calibration will be performed regularly to monitor any change in the transmission function of the telescope during the 5 year survey. The system consists of a monochromator based tunable light source that provides illumination on a dome flat that is monitored by calibrated photodiodes that allow us to measure the telescope throughput as a function of wavelength. Our system has a peak output power of 2 mW, equivalent to a flux of approximately 800 photons/s/pixel on DECam.

  9. Spectrophotometric retinal oximetry in pigs

    Traustason, Sindri; Kiilgaard, Jens Folke; Karlsson, Robert

    2013-01-01

    PURPOSE: To assess the validity of spectrophotometric retinal oximetry, by comparison to blood gas analysis and intra-vitreal measurements of partial pressure of oxygen (pO2). METHODS: Female domestic pigs were used for all experiments (n=8). Oxygen fraction in inspired air was changed using...... a mixture of room air, pure oxygen and pure nitrogen, ranging from 5% to 100% oxygen. Femoral arterial blood gas analysis and retinal oximetry was performed at each level of inspiratory oxygen fraction. Retinal oximetry was performed using a commercial instrument, the Oxymap Retinal Oximeter T1 (Oxymap ehf...... arterial oxygen saturation and the optical density ratio over retinal arteries revealed an approximately linear relationship (R(2) = 0.74, p = 3.4 x 10(-9)). In order to test the validity of applying the arterial calibration to veins, we compared non-invasive oximetry measurements to invasive pO2...

  10. REVIEW ARTICLE: Spectrophotometric applications of digital signal processing

    Morawski, Roman Z.

    2006-09-01

    Spectrophotometry is more and more often the method of choice not only in analysis of (bio)chemical substances, but also in the identification of physical properties of various objects and their classification. The applications of spectrophotometry include such diversified tasks as monitoring of optical telecommunications links, assessment of eating quality of food, forensic classification of papers, biometric identification of individuals, detection of insect infestation of seeds and classification of textiles. In all those applications, large numbers of data, generated by spectrophotometers, are processed by various digital means in order to extract measurement information. The main objective of this paper is to review the state-of-the-art methodology for digital signal processing (DSP) when applied to data provided by spectrophotometric transducers and spectrophotometers. First, a general methodology of DSP applications in spectrophotometry, based on DSP-oriented models of spectrophotometric data, is outlined. Then, the most important classes of DSP methods for processing spectrophotometric data—the methods for DSP-aided calibration of spectrophotometric instrumentation, the methods for the estimation of spectra on the basis of spectrophotometric data, the methods for the estimation of spectrum-related measurands on the basis of spectrophotometric data—are presented. Finally, the methods for preprocessing and postprocessing of spectrophotometric data are overviewed. Throughout the review, the applications of DSP are illustrated with numerous examples related to broadly understood spectrophotometry.

  11. Liquid waveguide spectrophotometric measurement of nanomolar ammonium in seawater based on the indophenol reaction with o-phenylphenol (OPP).

    Hashihama, Fuminori; Kanda, Jota; Tauchi, Ami; Kodama, Taketoshi; Saito, Hiroaki; Furuya, Ken

    2015-10-01

    We describe a highly sensitive colorimetric method for the determination of nanomolar concentrations of ammonium in seawater based on the indophenol reaction with o-phenylphenol [(1,1'-biphenyl)-2-ol, abbreviated as OPP]. OPP is available as non-toxic, stable flaky crystals with no caustic odor and has some advantages over phenol in practical use. The method was established by using a gas-segmented continuous flow analyzer equipped with two types of long path liquid waveguide capillary cell, LWCCs (100 cm and 200 cm) and an UltraPath (200 cm), which have inner diameters of 0.55 mm and 2 mm, respectively. The reagent concentrations, flow rates of the pumping tubes, and reaction path and temperature were determined on the basis of a manual indophenol blue method with OPP (Kanda, Water Res. 29 (1995) 2746-2750). The sample mixed with reagents that form indophenol blue dye was measured at 670 nm. Aged subtropical surface water was used as a blank, a matrix of standards, and the carrier. The detection limits of the analytical systems with a 100 cm LWCC, a 200 cm LWCC, and a 200 cm UltraPath were 6, 4, and 4 nM, respectively. These systems had high precision (<4% at 100 nM) and a linear dynamic range up to 200 nM. Non-linear baseline drift did not occur when using the UltraPath system. This is due to the elimination of cell clogging because of the larger inner diameter of the UltraPath compared to the LWCCs. The UltraPath system is thus more suitable for long-term measurements compared with the LWCC systems. The results of the proposed sensitive colorimetry and a conventional colorimetry for the determination of seawater samples showed no significant difference. The proposed analytical systems were applied to underway surface monitoring and vertical observation in the oligotrophic South Pacific. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Making transuranic assay measurements using modern controllers

    Kuckertz, T.H.; Caldwell, J.T.; Medvick, P.A.; Kunz, W.E.; Hastings, R.D.

    1987-01-01

    This paper describes methodology and computer-controlled instrumentation developed at the Los Alamos National Laboratory that accurately performs nondestructive assays of large containers bearing transuranic wastes and nonradioactive matrix materials. These assay systems can measure fissile isotopes with 1-mg sensitivity and spontaneous neutron-emitting isotopes at a 10-mg sensitivity. The assays are performed by neutron interrogation, detection, and counting in a custom assay chamber. An International Business Machines Personal Computer (IBM-PC) is used to control the CAMAC-based instrumentation system that acquires the assay data. 6 refs., 7 figs

  13. Differential spectrophotometric determination of plutonium

    Lecat, J.

    1980-01-01

    Differential spectrophotometric method is used for determination of plutonium reduced to oxydation state III+ by ascorbic acid, at 560 nm. Concentration of solutions is 4 g/l and accuracy of the method is better than 0,3% [fr

  14. Measurement of shared decision making - a review of instruments

    Scholl, I.; Koelewijn-van Loon, M.; Sepucha, K.; Elwyn, G.; Legare, F.; Harter, M.; Dirmaier, J.

    2011-01-01

    The last years have seen a clear move towards shared decision making (SDM) and increased patient involvement in many countries. However, as the field of SDM research is still relatively young, new instruments for the measurement of (shared) decision making (process, outcome and surrounding elements)

  15. Construção de uma cela de fluxo de longo caminho óptico para medidas espectrofotométricas Construction of a long-pathlength flow cell for spectrophotometric measurements

    Wanessa Roberto Melchert

    2008-01-01

    Full Text Available A simple and low-cost flow cell with 30 cm optical path for spectrophotometric measurements is described. It presents desirable characteristics such as low attenuation of the radiation beam and internal volume (75 µL comparable to that of a 1-cm conventional cell (80 µL. Despite the increase in optical path, the effect on sample dispersion was also similar to that attained in the commercial cell. The performance of the cell was assessed by the determination of phosphate based on the molybdenum blue method, yielding a linear response range between 0.05 and 0.8 mg L-1 phosphorus (r=0.999. The increase in sensitivity (30.4-fold in comparison with that obtained with a conventional 1-cm flow cell agreed with that estimated by the Lambert-Beer law.

  16. Convergent validity of two decision making style measures

    Berisha, Gentrit

    2018-04-01

    Full Text Available Decision making research has witnessed a growing number of studies on individual differences and decision making styles, yet the lack of comprehensive frameworks and widely accepted measures has hindered research for a long time. There is an ongoing debate on whether individuals’ styles dynamically change across time and situations according to circumstances. Furthermore, it is an open question whether these styles are mutually exclusive. Decision style measures seek to determine one’s dominant style as well as less used styles. To our knowledge this is the first study of the convergent validity of two widely used decision making style measures: The Decision Style Inventory (DSI and the General Decision Making Style (GDMS. The direction and strength of correlation between directive, analytical, conceptual and behavioral styles as measured by DSI and rational, intuitive, dependent, avoidant and spontaneous styles as measured by GDMS have been tested. Results of the current study are compared with previous studies that have used one or both of the instruments. Correlations between styles are consistent with findings from other studies using one of the decision style measures, but the strength of correlations indicates that there is no convergent validity between DSI and GDMS.

  17. Second derivative spectrophotometric determination of ...

    A new, simple, rapid, wide applicable range and reliable second derivative spectrophotometric method has been developed for determination of cyclophosphamide (CP) in bulk and pharmaceutical dosage forms. Calibration graph is linear in the concentration range of 25 - 200 μg/ml of CP with 10 μg/ml of detection limit and ...

  18. Spectrophotometric determination of eflornithine hydrochloride ...

    Purpose: To develop and validate a spectrophotometric method for the quantitative determination of eflornithine hydrochloride as a pure compound and in pharmaceutical formulations. Methods: The method involved the reaction of the target compound with vanillin reagent at specific pH 5.6 to produce a green reddish color ...

  19. Spectrophotometric determination of association constant

    2016-01-01

    Least-squares 'Systematic Trial-and-Error Procedure' (STEP) for spectrophotometric evaluation of association constant (equilibrium constant) K and molar absorption coefficient E for a 1:1 molecular complex, A + B = C, with error analysis according to Conrow et al. (1964). An analysis of the Charge...

  20. Spectrophotometric Determination of Eflornithine Hydrochloride ...

    Purpose: To develop and validate a spectrophotometric method for the quantitative determination of eflornithine hydrochloride as a pure compound and in pharmaceutical formulations. Methods: The method involved the reaction of the target compound with vanillin reagent at specific pH. 5.6 to produce a green reddish color ...

  1. Second derivative spectrophotometric determination of ...

    Hemn

    2013-11-13

    Nov 13, 2013 ... olanzapine in pharmaceutical formulation.Int.J.ChemTech. Res.2(1):756-761. Stanisz B, Paszun S, Lesniak M (2009). Validation of UV derivative spectrophotometric method for determination of benazepril hydrochloride in tablets and evaluation of its stability.ActaPoloniaePharmaceutica-Drug Research.

  2. Measuring local autonomy: A decision-making approach

    Fleurke, F.; Willemse, R.

    2006-01-01

    In studies on central-local relations it is common to assess local autonomy in a deductive way. The extent of local autonomy is determined by measuring the central legal and financial competence, after which the remaining room for local decision-making is determined. The outcome of this indirect

  3. Using measurement uncertainty in decision-making and conformity assessment

    Pendrill, L. R.

    2014-08-01

    Measurements often provide an objective basis for making decisions, perhaps when assessing whether a product conforms to requirements or whether one set of measurements differs significantly from another. There is increasing appreciation of the need to account for the role of measurement uncertainty when making decisions, so that a ‘fit-for-purpose’ level of measurement effort can be set prior to performing a given task. Better mutual understanding between the metrologist and those ordering such tasks about the significance and limitations of the measurements when making decisions of conformance will be especially useful. Decisions of conformity are, however, currently made in many important application areas, such as when addressing the grand challenges (energy, health, etc), without a clear and harmonized basis for sharing the risks that arise from measurement uncertainty between the consumer, supplier and third parties. In reviewing, in this paper, the state of the art of the use of uncertainty evaluation in conformity assessment and decision-making, two aspects in particular—the handling of qualitative observations and of impact—are considered key to bringing more order to the present diverse rules of thumb of more or less arbitrary limits on measurement uncertainty and percentage risk in the field. (i) Decisions of conformity can be made on a more or less quantitative basis—referred in statistical acceptance sampling as by ‘variable’ or by ‘attribute’ (i.e. go/no-go decisions)—depending on the resources available or indeed whether a full quantitative judgment is needed or not. There is, therefore, an intimate relation between decision-making, relating objects to each other in terms of comparative or merely qualitative concepts, and nominal and ordinal properties. (ii) Adding measures of impact, such as the costs of incorrect decisions, can give more objective and more readily appreciated bases for decisions for all parties concerned. Such

  4. Measurements of Saharan dust aerosols over the Eastern Mediterranean using elastic backscatter-Raman lidar, spectrophotometric and satellite observations in the frame of the EARLINET project

    A. Papayannis

    2005-01-01

    Full Text Available We report on the vertical distributions of Saharan dust aerosols over the N.E. Mediterranean region, which were obtained during a typical dust outbreak on August 2000, by two lidar systems located in Athens and Thessaloniki, Greece, in the frame of the European EARLINET project. MODIS and ground sun spectrophotometric data, as well as air-mass backward trajectories confirmed the existence of Saharan dust in the case examined, which was also successfully forecasted by the DREAM dust model. The lidar data analysis for the period 2000-2002 made possible, for the first time, an estimation of the vertical extent of free tropospheric dust layers [mean values of the aerosol backscatter and extinction coefficients and the extinction-to-backscatter ratio (lidar ratio, LR at 355 nm], as well as a seasonal distribution of Saharan dust outbreaks over Greece, under cloud-free conditions. A mean value of the lidar ratio at 355 nm was obtained over Athens (53±1 sr and over Thessaloniki (44±2 sr during the Saharan dust outbreaks. The corresponding aerosol optical thickness (AOT at 355 nm, in the altitude range 0-5 km, was 0.69±0.12 and 0.65±0.10 for Athens and Thessaloniki, respectively (within the dust layer the AOT was 0.23 and 0.21, respectively. Air-mass back-trajectory analysis performed in the period 2000-2002 for all Saharan dust outbreaks over the N.E. Mediterranean indicated the main pathways followed by the dust aerosols.

  5. Spectrophotometric determination of aluminium in steel with xylenol orange

    Majeed, A.; Javed, N.; Khan, M.S.

    1996-01-01

    Spectrophotometric determination of Aluminium in steel based on colour reaction between Aluminium and xylenol orange has been carried out. Red coloured complex formed in weak acidic solution is measured for its absorbance at 550 nm. The various optimum experimental conditions for Aluminium xylenol orange (Al-Xo) complex have been studied. (author)

  6. Salicylate-spectrophotometric determination of inorganic monochloramine

    Tao Hui; Chen Zhonglin; Li Xing; Yang Yanling; Li Guibai

    2008-01-01

    On the basis of classical Berthelot reaction, a simple salicylate-spectrophotometric method was developed for quantitative determination of inorganic monochloramine in water samples. With the catalysis of disodium pentacyanonitrosylferrate(III), inorganic monochloramine reacts with salicylate in equimolar to produce indophenol compound which has an intense absorption at 703 nm. Parameters that influence method performance, such as pH, dosage of salicylate and nitroprussiate and reaction time, were modified to enhance the method performance. By using this method, inorganic monochloramine can be distinguished from organic chloramines and other inorganic chlorine species, such as free chlorine, dichloramine, and trichloramine. The molar absorptivities of the final products formed by these compounds are below ±3% of inorganic monochloramine, because of the α-N in them have only one exchangeable hydrogen atom, and cannot react with salicylate to produce the indophenol compound. The upper concentrations of typical ions that do not interfere with the inorganic monochloramine determination are also tested to be much higher than that mostly encountered in actual water treatment. Case study demonstrates that the results obtained from this method are lower than DPD-titrimetric method because the organic chloramines formed by chlorination of organic nitrogenous compounds give no response in the newly established method. And the result measured by salicylate-spectrophotometric method is coincident with theoretical calculation

  7. DECal: A Spectrophotometric Calibration System For DECam.

    Rheault, Jean-Philippe; DePoy, D. L.; Marshall, J. L.; Prochaska, T.; Allen, R.; Wise, J.; Martin, E.

    2012-01-01

    We present preliminary results for a spectrophotometric calibration system that is being implemented as part of the DES DECam project at the Blanco 4 meter at CTIO. Our calibration system uses a 2nm wide tunable source to measure the instrumental response function of the telescope from 300nm up to 1100nm. This calibration will be performed regularly to monitor any change in the transmission function. The system consists of a monochromator based tunable light source that provides illumination on a dome flat that is monitored by calibrated photodiodes and allow us to measure the throughput as a function of wavelength. Our system has an output power of 2 mW, equivalent to a flux of approximately 800 photons/s/pixel on DECam. Preliminary results of the measure of the throughput of the telescope will be presented.

  8. SPECTROPHOTOMETRIC DETERMINATION OF PIZOTEFIN ...

    B. S. Chandravanshi

    respectively. Different experimental conditions for the two methods were optimized. Beer's law was obeyed in the concentration ranges of .... mixed in various proportions and the volume was diluted in a 10-mL volumetric flask with acetonitrile. The absorbance of the resulting solutions was measured at optimum wavelengths.

  9. A new importance measure for risk-informed decision making

    Borgonovo, E.; Apostolakis, G.E.

    2000-01-01

    Recently, several authors pointed out that the traditional importance measures had limitations. In this study, the problem through an analysis at the parameter level was investigated and a new measure was introduced. The measure was based on small parameter variations and is capable of accounting for the importance of a group of components/parameters. The definition, computational steps, and an application of a new importance measure for risk-informed decision making were presented here. Unlike traditional importance measures, differential importance measure (DIM) deals with changes in the various parameters that determine the unavailability/unreliability of a component, e.g., failure rates, common-cause failure rates, individual human errors. The importance of the component unavailability/unreliability can be calculated from the importance of the parameters. DIM can be calculated for the frequency of initiating events, while risk achievement worth (RAW) is limited to binary events, e.g., component unavailability. The changes in parameters are 'small'. This is more realistic than the drastic assumption in RAW that the component is always down. DIM is additive. This allows the evaluation of the impact of changes, such as the relaxation of quality assurance requirements, which affect groups of parameters, e.g., the failure rates of a group of pumps. (M.N.)

  10. Neuroeconomic Measures of Social Decision-Making Across the Lifespan

    Lusha eZhu

    2012-09-01

    Full Text Available Social and decision-making deficits are often the first symptoms of a striking number of neurodegenerative disorders associated with aging. These includes not only disorders that directly impact dopamine and basal ganglia, such as Parkinson’s disorder, but also degeneration in which multiple neural pathways are affected over the course of normal aging. The impact of such deficits can be dramatic, as in cases of financial fraud, which disproportionately affect the elderly. Unlike memory and motor impairments, however, which are readily recognized as symptoms of more serious underlying neurological conditions, social and decision-making deficits often do not elicit comparable concern in the elderly. Furthermore, few behavioral measures exist to quantify these deficits, due in part to our limited knowledge of the core cognitive components or their neurobiological substrates. Here we probe age-related differences in decision-making using a game theory paradigm previously shown to dissociate contributions of basal ganglia and prefrontal regions to behavior. Combined with computational modeling, we provide evidence that behavioral deficits in elderly participants is driven primarily by an over-reliance in trial-and-error reinforcement learning that does not take into account the strategic context, which may underlie elderly’s susceptibility to fraud.

  11. Eye tracking measures of uncertainty during perceptual decision making.

    Brunyé, Tad T; Gardony, Aaron L

    2017-10-01

    Perceptual decision making involves gathering and interpreting sensory information to effectively categorize the world and inform behavior. For instance, a radiologist distinguishing the presence versus absence of a tumor, or a luggage screener categorizing objects as threatening or non-threatening. In many cases, sensory information is not sufficient to reliably disambiguate the nature of a stimulus, and resulting decisions are done under conditions of uncertainty. The present study asked whether several oculomotor metrics might prove sensitive to transient states of uncertainty during perceptual decision making. Participants viewed images with varying visual clarity and were asked to categorize them as faces or houses, and rate the certainty of their decisions, while we used eye tracking to monitor fixations, saccades, blinks, and pupil diameter. Results demonstrated that decision certainty influenced several oculomotor variables, including fixation frequency and duration, the frequency, peak velocity, and amplitude of saccades, and phasic pupil diameter. Whereas most measures tended to change linearly along with decision certainty, pupil diameter revealed more nuanced and dynamic information about the time course of perceptual decision making. Together, results demonstrate robust alterations in eye movement behavior as a function of decision certainty and attention demands, and suggest that monitoring oculomotor variables during applied task performance may prove valuable for identifying and remediating transient states of uncertainty. Published by Elsevier B.V.

  12. Neuroeconomic measures of social decision-making across the lifespan.

    Zhu, Lusha; Walsh, Daniel; Hsu, Ming

    2012-01-01

    Social and decision-making deficits are often the first symptoms of a striking number of neurodegenerative disorders associated with aging. These includes not only disorders that directly impact dopamine and basal ganglia, such as Parkinson's disorder, but also degeneration in which multiple neural pathways are affected over the course of normal aging. The impact of such deficits can be dramatic, as in cases of financial fraud, which disproportionately affect the elderly. Unlike memory and motor impairments, however, which are readily recognized as symptoms of more serious underlying neurological conditions, social and decision-making deficits often do not elicit comparable concern in the elderly. Furthermore, few behavioral measures exist to quantify these deficits, due in part to our limited knowledge of the core cognitive components or their neurobiological substrates. Here we probe age-related differences in decision-making using a game theory paradigm previously shown to dissociate contributions of basal ganglia and prefrontal regions to behavior. Combined with computational modeling, we provide evidence that age-related changes in elderly participants are driven primarily by an over-reliance in trial-and-error reinforcement learning that does not take into account the strategic context, which may underlie cognitive deficits that contribute to social vulnerability in elderly individuals.

  13. Ocean Health X-Prize testing of a Simplified Spectrophotometric pH Sensor

    Darlington, R. C.; DeGrandpre, M. D.; Spaulding, R. S.; Beck, J. C.

    2016-02-01

    Since the Industrial Revolution, the world's oceans have absorbed increasing amounts of CO2, resulting in a >0.1 reduction in the pH of surface waters. This acidification of the oceans has many far reaching impacts on marine life. There is, therefore, great need of quality instrumentation to assess and follow the changing carbonate system. To address this need, we have developed a simplified spectrophotometric pH sensor with accuracy and precision suitable for sea surface measurements with special emphasis on reduced size and cost. The reduced size will allow deployment of sensors on a much wider variety of platforms than are currently possible, and the reduced cost will make the instruments available to a broader research community. This prototype pH instrument was entered into the Wendy Schmidt Ocean Health X-Prize, an incentivized global competition to spur innovation in sensors to monitor ocean acidification's impact on marine ecosystems. Results from the three phases of competition which explored accuracy, precision, and stability culminating in a one month field trial are detailed. The prototype proved to be highly accurate (+/-0.009), with good precision (+/-0.004) and stability showing drift indistinguishable from that of the validation measurements. The innovations that enabled this sensor to succeed in the competition could allow for deployment of spectrophotometric sensors on new platforms such as NOAAs Global Drifter Program, a network of non-recovered surface drifting buoys, which would greatly extend the spatial and temporal resolution of ocean acidification measurements.

  14. Plutonium spectrophotometric analysis

    Esteban, A.; Cassaniti, P.; Orosco, E.H.

    1990-01-01

    Plutonium ions in solution have absorption spectra so different that it is possible to use them for analytical purposes. Detailed studies have been performed in nitric solutions. Some very convenient methods for the determination of plutonium and its oxidation states, especially the ratios Pu(III):Pu(IV) and Pu(IV):Pu(VI) in a mixture of both, have been developed. These methods are described in this paper, including: a) Absorption spectra for plutonium (III), (IV), (VI) and mixtures. b) Relative extinction coefficients for the above mentioned species. c) Dependences of the relative extinction coefficients on the nitric acid concentration and the plutonium VI deviation from the Beer-Lambert law. The developed methods are simple and rapid and then, suitable in process control. Accuracy is improved when relative absorbance measurements are performed or controlled the variables which have effect on the spectra and extinction coefficients. (Author) [es

  15. Simultaneous Spectrophotometric Determination of Valsartan and ...

    Purpose: To develop a direct, simple and extraction-free spectrophotometric method for the simultaneous estimation of valsartan and ezetimibe in pharmaceuticals. Methods: A spectrophotometric method for the determination of valsartan and ezetimibe was developed using acidic dyes, namely, bromophenol blue (BPB) ...

  16. High precision spectrophotometric analysis of thorium

    Palmieri, H.E.L.

    1984-01-01

    An accurate and precise determination of thorium is proposed. Precision of about 0,1% is required for the determination of macroquantities of thorium when processed. After an extensive literature search concerning this subject, spectrophotometric titration has been chosen, using dissodium ethylenediaminetetraacetate (EDTA) solution and alizarin-S as indicator. In order to obtain such a precision, an amount of 0,025 M EDTA solution precisely measured has been added and the titration was completed with less than 5 ml of 0,0025 M EDTA solution. It is usual to locate the end-point graphically, by plotting added titrant versus absorbance. The non-linear minimum square fit, using the Fletcher e Powell's minimization process and a computer programme. Besides the equivalence point, other parameters of titration were determined: the indicator concentration, the absorbance of the metal-indicator complex, and the stability constants of the metal-indicator and the metal-EDTA complexes. (Author) [pt

  17. Thorium spectrophotometric analysis with high precision

    Palmieri, H.E.L.

    1983-06-01

    An accurate and precise determination of thorium is proposed. Precision of about 0,1% is required for the determination of macroquantities of thorium processed. After an extensive literature search concerning this subject, spectrophotometric titration has been chosen, using disodium ethylenediaminetetraacetate (EDTA) solution and alizarin S as indicator. In order to obtain such a precision, an amount of 0,025 M EDTA solution precisely measured has been added and the titration was completed with less than 5 ml of 0,0025 M EDTA solution. It is usual to locate the end-point graphically, by plotting added titrant versus absorbance. The non-linear minimum square fit, using the Fletcher e Powell's minimization process and a computer program. (author)

  18. Spectrophotometric determination of silicon in silumin matrix

    Samanta, Papu; Pandey, K.L.; Kumar, Pradeep; Bagchi, A.C.; Abdulla, K.K.

    2015-01-01

    In dispersion fuel, fissile material is dispersed in inert matrix. Aluminum-silicon-nickel (silumin) alloy is employed as inert matrix owing to its high thermal conductivity, high castability, high corrosion resistance. All these properties depend on the chemical composition and the structure of silumin. Silicon is stringent specification in silumin. A spectrophotometric method has been developed for the determination of silicon content in silumin matrix. Silumin matrix was fused with LiOH and subsequent dissolution in water along with few drops of conc. sulphuric acid. The molybodo-silicic formed by the addition of ammonium molybdate is reduced to molybdenum blue by ascorbic acid in the presence of antimony. The absorbance was measured at 810 nm. Aluminum and nickel were found to be non-interfering with the silicon determination. (author)

  19. The spectrophotometric determination of boron in tourmalines

    LJILJANA JAKSIC

    2005-02-01

    Full Text Available A procedure for the spectrophotometric determination of macro amounts of boron in tourmaline with azomethine H is described. The used tourmaline concentrate was obtained by magnetic separation and heavy-liquids purification of the schorl zone of pegmatite or granite aplite. The samples of tourmaline were decomposed by fusion with anhydrous sodium carbonate and taken up in dilute hydrochloric acid. The interfering effects of iron and aluminium were eliminated by masking with an EDTA – NTA solution. After pH adjustment, the boron was reacted with azomethine H and the absorbance of the obtained coloured complex was measured at 415 nm. The results are compared with those obtained by other procedures. The relative error of the determination was less than 3 %.

  20. Extractive spectrophotometric determination of thorium

    Venkatesan, M.; Gopalakrishnan, V.; Ramanujam, A.; Nadkarni, M.N.

    1981-01-01

    An extractive spectrophotometric method has been standardized for the analysis of 0.2 to 1.6 milligrams of thorium present in nitric acid solutions. The method involves the extraction of thorium from nitric acid solutions into 0.5 M thenoyl trifluoro acetone (HTTA) in benzene and its direct estimation from the organic extract by spectrophotometry as Thoron colour complex. In this method, interference due to iron upto 5 milligrams can be suppressed by adding ascorbic acid in the ratio of 1:2 prior to HTTA extraction. Uranium(VI) does not interefere even when present in 2000 times the amount of thorium. Plutonium and cerium do not interfere at one milligram level whereas zirconium interferes in this method. The overall error variation and precision of this method has been determined to be +- 3.5%. (author)

  1. Spectrophotometric determination of procainamide hydrochloride using sodium periodate

    Al-Tamrah, S.; Al-Abbad, S.

    2015-01-01

    A simple spectrophotometric method has been described for the determination of procainamide hydrochloride. The method is based on the oxidation of procainamide hydrochloride by sodium periodate in the presence of sulfuric acid and measurement of the absorbance of the violet color formed at 531 nm. Parameters affecting the reaction were studied and conditions were optimized. Linear calibration graph was obtained from 50 to 700 μg ml−1 of procainamide hydrochloride and the limit of detection wa...

  2. Reliability and accuracy of Crystaleye spectrophotometric system.

    Chen, Li; Tan, Jian Guo; Zhou, Jian Feng; Yang, Xu; Du, Yang; Wang, Fang Ping

    2010-01-01

    to develop an in vitro shade-measuring model to evaluate the reliability and accuracy of the Crystaleye spectrophotometric system, a newly developed spectrophotometer. four shade guides, VITA Classical, VITA 3D-Master, Chromascop and Vintage Halo NCC, were measured with the Crystaleye spectrophotometer in a standardised model, ten times for 107 shade tabs. The shade-matching results and the CIE L*a*b* values of the cervical, body and incisal regions for each measurement were automatically analysed using the supporting software. Reliability and accuracy were calculated for each shade tab both in percentage and in colour difference (ΔE). Difference was analysed by one-way ANOVA in the cervical, body and incisal regions. range of reliability was 88.81% to 98.97% and 0.13 to 0.24 ΔE units, and that of accuracy was 44.05% to 91.25% and 1.03 to 1.89 ΔE units. Significant differences in reliability and accuracy were found between the body region and the cervical and incisal regions. Comparisons made among regions and shade guides revealed that evaluation in ΔE was prone to disclose the differences. measurements with the Crystaleye spectrophotometer had similar, high reliability in different shade guides and regions, indicating predictable repeated measurements. Accuracy in the body region was high and less variable compared with the cervical and incisal regions.

  3. New development of spectrophotometric analysis of thorium

    Yang Xiangzhen

    1992-01-01

    This review covers new development of spectrophotometric determination of thorium since 1980's. The methods include general spectrophotometry, double wavelength spectrophotometry, catalytic spectrophotometry, total differential spectrophotometry, derivative spectrophotometry and fluorescent spectrophotometry, etc

  4. Extractive Spectrophotometric Determination of Omeprazole in ...

    Erah

    Abstract. Purpose: To develop a simple, rapid and selective method for the extractive spectrophotometric determination of .... The colour intensity of the organic layer had shown a very .... considerable attention for quantitative analyses of many ...

  5. Spectrophotometric Determination Of Heavy Metals In Cosmetics

    ISSN 1597-6343. Spectrophotometric Determination Of Heavy Metals In Cosmetics ... analysed using atomic absorption spectrophotometer – coupled with a hydride ... presence of arsenic (As), mercury (Hg), cadmium (Cd) and lead. (Pb) in ...

  6. Optimization, Validation and Application of Spectrophotometric ...

    ... 3Research Center of Food and Drug Evaluation, Wuhan University, Wuhan 430071, ... Methods: Spectrophotometric HMG-CoA reductase detection in male Wistar ... protein expression in various regulatory ... reagents were analytical grade.

  7. Development of Vanadometric System for Spectrophotometric ...

    rugged, and compares well with some complex methods for assay of timolol maleate in ... 3-[[4-(4-morpholinyl)-1, 2, 5-thiadiazol-3-yl] oxy]- ... preparation methods, costly reagents, expertise ..... chemical characterization, UV spectrophotometric.

  8. Development of Ultraviolet Spectrophotometric Method for Analysis ...

    HP

    Method for Analysis of Lornoxicam in Solid Dosage. Forms. Sunit Kumar Sahoo ... testing. Mean recovery was 100.82 % for tablets. Low values of % RSD indicate .... Saharty E, Refaat YS, Khateeb ME. Stability-. Indicating. Spectrophotometric.

  9. Spectrophotometric Rapid-Response Classification of Near-Earth Objects

    Mommert, Michael; Trilling, David; Butler, Nat; Axelrod, Tim; Moskovitz, Nick; Jedicke, Robert; Pichardo, Barbara; Reyes-Ruiz, Mauricio

    2015-08-01

    Small NEOs are, as a whole, poorly characterized, and we know nothing about the physical properties of the majority of all NEOs. The rate of NEO discoveries is increasing each year, and projects to determine the physical properties of NEOs are lagging behind. NEOs are faint, and generally even fainter by the time that follow-up characterizations can be made days or weeks after their discovery. There is a need for a high-throughput, high-efficiency physical characterization strategy in which hundreds of faint NEOs can be characterized each year. Broadband photometry in the near-infrared is sufficiently diagnostic to assign taxonomic types, and hence constrain both the individual and ensemble properties of NEOs.We present results from our rapid response near-infrared spectrophotometric characterization program of NEOs. We are using UKIRT (on Mauna Kea) and the RATIR instrument on the 1.5m telescope at the San Pedro Martir Observatory (Mexico) to allow us to make observations most nights of the year in robotic/queue mode. We derive taxonomic classifications for our targets using machine-learning techniques that are trained on a large sample of measured asteroid spectra. For each target we assign a probability for it to belong to a number of different taxa. Target selection, observation, data reduction, and analysis are highly automated, requiring only a minimum of user interaction, making this technique powerful and fast. Our targets are NEOs that are generally too faint for other characterization techniques, or would require many hours of large telescope time.

  10. Spectrophotometric Examination of Rough Print Surfaces

    Erzsébet Novotny

    2011-05-01

    Full Text Available The objective was to assess the impact of the surface texture of individual creative paper types (coated or patternedon the quality of printing and to identify to what extent the various creative paper types require specific types ofspectrophotometers. We used stereomicroscopic images to illustrate unprinted and printed surfaces of creative papertypes. Surface roughness was measured to obtain data on the unevenness of surfaces. Spectrophotometric tests wereused to select the most suitable spectrophotometer from meters with different illumination setup for testing anygiven print. For the purpose of testing, we used spectrophotometers which are commonly available generally used totest print products for colour accuracy. With the improvement of measuring geometries, illumination setup, colourmeasurement becomes more and more capable of producing reliable results unaffected by surface textures. Our testshave proved this fact by showing that the GretagMacbeth Spectrolino with annular illumination is less sensitive tosurface texture than the X-Rite Spetrodensitometer and the Techkon SpetroDens with directional illumination. Furthertests have brought us to the conclusion that there is a difference even between the two devices with directionalillumination. While the X-Rite 530 Spectrodensitometer is more suitable for testing coated surfaces, the TechkonSpectroDens can come close to ΔE*ab values produced by the annular illuminated device for textured surfaces.

  11. Spectrophotometric observations of symbiotic stars

    Ipatov, A.P.; Yudin, B.F.

    1985-01-01

    The data of spectrophotometric observations of symbiotic stars Z And, AX Per, CI Cyg, BF Cyg, YY Her, V 443 Her, AG Dra, AG Peg, AS 296, EG And, V 1016 Cyg, and HM Sge are presented. The spectral range of observations is 3300-7500 A, resolution is 50 A. The data obtained allowed to reveal specific characteristics inherent to the radiation of symbiotic stars and to estimate the parameters of their individual components. Analysis of the spectra of symbiotic stars in the range of 1300-7500 A wavelengths suggests a hypothesis, according to which a hot source in the Rayleigh - Jeans spectral range has a less steep inclination in the energy distribution, than a black-body one. A disk, formed during cold star substance accretion through an internal Lagrangian point onto a denser component of the system, can play the role of the source. In this case one manages to obtain the energy distribution in the symbiotic star spectrum consistent with the observed distribution

  12. Spectrophotometric Analysis of Phenolic Compounds in Grapes and Wines.

    Aleixandre-Tudo, Jose Luis; Buica, Astrid; Nieuwoudt, Helene; Aleixandre, Jose Luis; du Toit, Wessel

    2017-05-24

    Phenolic compounds are of crucial importance for red wine color and mouthfeel attributes. A large number of enzymatic and chemical reactions involving phenolic compounds take place during winemaking and aging. Despite the large number of published analytical methods for phenolic analyses, the values obtained may vary considerably. In addition, the existing scientific knowledge needs to be updated, but also critically evaluated and simplified for newcomers and wine industry partners. The most used and widely cited spectrophotometric methods for grape and wine phenolic analysis were identified through a bibliometric search using the Science Citation Index-Expanded (SCIE) database accessed through the Web of Science (WOS) platform from Thompson Reuters. The selection of spectrophotometry was based on its ease of use as a routine analytical technique. On the basis of the number of citations, as well as the advantages and disadvantages reported, the modified Somers assay appears as a multistep, simple, and robust procedure that provides a good estimation of the state of the anthocyanins equilibria. Precipitation methods for total tannin levels have also been identified as preferred protocols for these types of compounds. Good reported correlations between methods (methylcellulose precipitable vs bovine serum albumin) and between these and perceived red wine astringency, in combination with the adaptation to high-throughput format, make them suitable for routine analysis. The bovine serum albumin tannin assay also allows for the estimation of the anthocyanins content with the measurement of small and large polymeric pigments. Finally, the measurement of wine color using the CIELab space approach is also suggested as the protocol of choice as it provides good insight into the wine's color properties.

  13. Spectrophotometric determination of substrate-borne polyacrylamide.

    Lu, Jianhang; Wu, Laosheng

    2002-08-28

    Polyacrylamides (PAMs) have wide application in many industries and in agriculture. Scientific research and industrial applications manifested a need for a method that can quantify substrate-borne PAM. The N-bromination method (a PAM analytical technique based on N-bromination of amide groups and spectrophotometric determination of the formed starch-triiodide complex), which was originally developed for determining PAM in aqueous solutions, was modified to quantify substrate-borne PAM. In the modified method, the quantity of substrate-borne PAM was converted to a concentration of starch-triiodide complex in aqueous solution that was then measured by spectrophotometry. The method sensitivity varied with substrates due to sorption of reagents and reaction intermediates on the substrates. Therefore, separate calibration for each substrate was required. Results from PAM samples in sand, cellulose, organic matter burnt soils, and clay minerals showed that this method had good accuracy and reproducibility. The PAM recoveries ranged from 95.8% to 103.7%, and the relative standard deviations (n = 4) were application and facilitating PAM-related research.

  14. The Spectrophotometric Analysis and Modeling of Sunscreens

    Walters, Christina; Keeney, Allen; Wigal, Carl T.; Johnston, Cynthia R.; Cornelius, Richard D.

    1997-01-01

    Sunscreens and their SPF (Sun Protection Factor) values are the focus of this experiment that includes spectrophotometric measurements and molecular modeling. Students suspend weighed amounts of sunscreen lotions graded SPF 4, 6, 8, 15, 30, and 45 in water and dissolve aliquots of the aqueous suspensions in propanol. The expected relationship of absorbance proportional to log10(SPF) applies at 312 nm where a maximum in absorbance occurs for the sunscreen solutions. Results at 330 nm give similar results and are more accessible using spectrometers routinely available in the introductory laboratory. Sunscreens constitute a suitable class of compounds to use for modeling electronic spectra, and using the computer for the active ingredients ethylhexyl para-methoxycinnamate, oxybenzone, 2-ethylhexyl salicylate, and octocrylene found in commercially available formulations typically predicts the absorption maxima within 10 nm. This experiment lets students explore which compounds have the potential to function as sunscreen agents and thereby see the importance of a knowledge of chemistry to the formulation of household items.

  15. Standard guide for making quality nondestructive assay measurements

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This guide is a compendium of Quality Measurement Practices for performing measurements of radioactive material using nondestructive assay (NDA) instruments. The primary purpose of the guide is to assist users in arriving at quality NDA results, that is, results that satisfy the end user’s needs. This is accomplished by providing an acceptable and uniform basis for the collection, analysis, comparison, and application of data. The recommendations are not compulsory or prerequisites to achieving quality NDA measurements, but are considered contributory in most areas. 1.2 This guide applies to the use of NDA instrumentation for the measurement of nuclear materials by the observation of spontaneous or stimulated nuclear radiations, including photons, neutrons, or the flow of heat. Recommended calibration, operating, and assurance methods represent guiding principles based on current NDA technology. The diversity of industry-wide nuclear materials measurement applications and instrumentation precludes disc...

  16. Method of making self-calibrated displacement measurements

    Pedersen, H.N.

    1977-01-01

    A method for monitoring the displacement of an object having an acoustically reflective surface at least partially submerged in an acoustically conductive medium is described. The reflective surface is designed to have a stepped interface responsive to an incident acoustic pulse to provide separate discrete reflected pulses to a receiving transducer. The difference in the time of flight of the reflected acoustic signals corresponds to the known step height and the time of travel of the signals to the receiving transducer provides a measure of the displacement of the object. Accordingly, the reference step length enables simultaneous calibration of each displacement measurement. 3 claims, 3 figures

  17. Improving Teacher Evaluation Systems: Making the Most of Multiple Measures

    Grissom, Jason A., Ed.; Youngs, Peter, Ed.

    2015-01-01

    This is the first book to gather and address what we have learned about the impacts and challenges of data-intensive teacher evaluation systems--a defining characteristic of the current education policy landscape. Expert researchers and practitioners speak to what we know (and what remains to be known) about evaluation measures themselves, the…

  18. Blind quantum computation protocol in which Alice only makes measurements

    Morimae, Tomoyuki; Fujii, Keisuke

    2013-05-01

    Blind quantum computation is a new secure quantum computing protocol which enables Alice (who does not have sufficient quantum technology) to delegate her quantum computation to Bob (who has a full-fledged quantum computer) in such a way that Bob cannot learn anything about Alice's input, output, and algorithm. In previous protocols, Alice needs to have a device which generates quantum states, such as single-photon states. Here we propose another type of blind computing protocol where Alice does only measurements, such as the polarization measurements with a threshold detector. In several experimental setups, such as optical systems, the measurement of a state is much easier than the generation of a single-qubit state. Therefore our protocols ease Alice's burden. Furthermore, the security of our protocol is based on the no-signaling principle, which is more fundamental than quantum physics. Finally, our protocols are device independent in the sense that Alice does not need to trust her measurement device in order to guarantee the security.

  19. Make

    Frauenfelder, Mark

    2012-01-01

    The first magazine devoted entirely to do-it-yourself technology projects presents its 29th quarterly edition for people who like to tweak, disassemble, recreate, and invent cool new uses for technology. MAKE Volume 29 takes bio-hacking to a new level. Get introduced to DIY tracking devices before they hit the consumer electronics marketplace. Learn how to build an EKG machine to study your heartbeat, and put together a DIY bio lab to study athletic motion using consumer grade hardware.

  20. Spectrophotometric determination of procainamide hydrochloride using sodium periodate

    S. Al-Tamrah

    2015-09-01

    Full Text Available A simple spectrophotometric method has been described for the determination of procainamide hydrochloride. The method is based on the oxidation of procainamide hydrochloride by sodium periodate in the presence of sulfuric acid and measurement of the absorbance of the violet color formed at 531 nm. Parameters affecting the reaction were studied and conditions were optimized. Linear calibration graph was obtained from 50 to 700 μg ml−1 of procainamide hydrochloride and the limit of detection was 25 μg ml−1. The method was successfully applied for the determination of procainamide hydrochloride in pharmaceutical preparation.

  1. Validation of different spectrophotometric methods for determination of vildagliptin and metformin in binary mixture

    Abdel-Ghany, Maha F.; Abdel-Aziz, Omar; Ayad, Miriam F.; Tadros, Mariam M.

    New, simple, specific, accurate, precise and reproducible spectrophotometric methods have been developed and subsequently validated for determination of vildagliptin (VLG) and metformin (MET) in binary mixture. Zero order spectrophotometric method was the first method used for determination of MET in the range of 2-12 μg mL-1 by measuring the absorbance at 237.6 nm. The second method was derivative spectrophotometric technique; utilized for determination of MET at 247.4 nm, in the range of 1-12 μg mL-1. Derivative ratio spectrophotometric method was the third technique; used for determination of VLG in the range of 4-24 μg mL-1 at 265.8 nm. Fourth and fifth methods adopted for determination of VLG in the range of 4-24 μg mL-1; were ratio subtraction and mean centering spectrophotometric methods, respectively. All the results were statistically compared with the reported methods, using one-way analysis of variance (ANOVA). The developed methods were satisfactorily applied to analysis of the investigated drugs and proved to be specific and accurate for quality control of them in pharmaceutical dosage forms.

  2. Making a measurable difference in advanced Huntington disease care.

    Moskowitz, Carol Brown; Rao, Ashwini K

    2017-01-01

    Neurologists' role in the care of people with advanced Huntington disease (HD) (total functional capacity speech and language pathology), behavioral and psychiatric professionals for problem-solving strategies, which must be reviewed with direct care staff before implementation; (3) encourage and support qualitative and quantitative interdisciplinary research studies, and randomized controlled studies of nonpharmacologic interventions; and (4) assist in the development of meaningful measures to further document what works to provide a good quality of life for the patient and family and a comfortable thoughtful approach to a good death. Collaborative models of care depend on: (1) clear communication; (2) ongoing education and support programs; with (3) pharmacologic and rehabilitation interventions, always in the context of respect for the person with HD, a preservation of the individuals' dignity, autonomy, and individual preferences. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Spectrophotometric determination of proteins associated with ...

    Twenty six Aeromonas isolates from fishes, poultry and humans in Zaria were quantified for total soluble proteins (enzymes) profiles in January, 2007 by spectrophotometric (Biuret) method. Isolates were grown on Brain Heart Infusion (BHI) broth, they were incubated at 370C and centrifuged at 1,000 g/dl using harous ...

  4. Uranium fluorides analysis. Titanium spectrophotometric determination

    Anon.

    Titanium determination in uranium hexafluoride in the range 0.7 to 100 microgrammes after transformation of uranium fluoride in sulfate. Titanium is separated by extraction with N-benzoylphenylhydroxylamine, reextracted by hydrochloric-hydrofluoric acid. The complex titanium-N-benzoylphenylhydroxylamine is extracted by chloroform. Spectrophotometric determination at 400 nm [fr

  5. SPECTROPHOTOMETRIC DETERMINATION OF NITRITE BY ITS ...

    Preferred Customer

    sources of nitrite include intensive use of chemical nitrogenous fertilizers, ... The current paper describes another kinetic spectrophotometric method for determination of ... s at λmax = 570 nm (allowing a lag time of 5 s) against water as reference. ... samples and the total amount of the analyte was estimated by applying the ...

  6. Spectrophotometric determination of uranium using quercetin

    Barros, A.R.

    1972-10-01

    A spectrophotometric method for quantitative determination of uranium, using a flavone (quercetin) as complexing agent, is described. The method is based on the reaction between uranyl ion and alcoholic solution of quercetin with a complex formation of intense yellow color. (M.C.L.) [pt

  7. Spectrophotometric Methods for the Determination of Ketoconazole ...

    Spectrophotometric Methods for the Determination of Ketoconazole in Pharmaceutical Dosage Forms. ... Tropical Journal of Pharmaceutical Research ... Methods: The first method (A) was based on the oxidation of the studied drug by a known excess of cerium (IV) as an oxidizing agent and subsequent determination of ...

  8. Kinetic spectrophotometric determination of some fluoroquinolone ...

    A simple and sensitive kinetic spectrophotometric method was developed for the determination of some fluoroquinolonea antibiotics; gemifloxacin mesylate, moxifloxacin hydrochloride and gatifloxacin in bulk and in pharmaceutical preparations. The method is based upon a kinetic investigation of the oxidation reaction of ...

  9. Development and Application of Kinetic Spectrophotometric Method ...

    Purpose: To develop an improved kinetic-spectrophotometric procedure for the determination of metronidazole (MNZ) in pharmaceutical formulations. Methods: The method is based on oxidation reaction of MNZ by hydrogen peroxide in the presence of Fe(II) ions at pH 4.5 (acetate buffer). The reaction was monitored ...

  10. Spectrophotometric Determination of Trimipramine in Tablet Dosage ...

    Purpose: To develop and validate simple, rapid and sensitive spectrophotometric procedures for determination of trimipramine in tablet dosage form. Methods: The methods were based on the interaction of trimipramine as n-electron donor with the ο-acceptor, iodine and various π-acceptors, namely: chloranil (CH), ...

  11. A Sensitive Validated Spectrophotometric Method for the Determination of Flucloxacillin Sodium

    R. Singh Gujral

    2009-01-01

    Full Text Available A simple and sensitive spectrophotometric method has been proposed for the determination of flucloxacillin sodium. The determination method is based on charge transfer complexation reaction of the drug with iodine in methanol-dichloromethane medium. The absorbance was measured at 362 nm against the reagent blank. Under optimized experimental conditions, Beer's law is obeyed in the concentration ranges 1-9 μg/mL for flucloxacillin. The method was validated for specificity, linearity, precision, accuracy. The degree of linearity of the calibration curves, the percent recoveries, limit of detection and quantitation for the spectrophotometric method were determined. No interferences could be observed from the additives commonly present in the pharmaceutical formulations. The method was successfully applied for in vitro determination of human urine samples with low RSD value. This is simple, specific, accurate and sensitive spectrophotometric method.

  12. Effect of bilirubin on the spectrophotometric and radionuclide assay for serum angiotensin-converting enzyme

    Saxe, A.W.; Hollinger, M.A.; Essam, T.

    1986-01-01

    The effect of bilirubin on serum angiotensin-converting enzyme (ACE) activity was studied with spectrophotometric and radionuclide assays. In the spectrophotometric assay addition of bilirubin to normal serum from dog, mouse, and human produced a dose-related inhibition of ACE activity. A 50% decrease in human ACE activity was produced by the addition of approximately 250 mg/L in vitro. Serum from icteric patients with elevated bilirubin was also associated with a reduction in ACE activity in the spectrophotometric assay. A 50% decrease in ACE activity in these samples was associated with a serum bilirubin of approximately 220 mg/L. In the radionuclide assay, however, addition of bilirubin to normal human serum failed to reduce measured ACE activity. The use of a radionuclide assay for serum ACE in clinical samples offers the advantage of less interference from serum bilirubin

  13. Spectrophotometric determination of the ASTM color of diesel oil

    Douglas Willian Emanuel Alves Santana; Marcelle Prates Sepulveda; Paulo Jorge Sanches Barbeira

    2007-03-15

    One of the parameters analyzed to determine the quality of diesel oil is its ASTM color. Changes in color may be indicative of problems in the production process, contamination, degradation or the oxidation of diesel. The methodology recommended for determining the color of automotive diesel oil samples is the colorimetry according to standard ASTM D1500, in which a sample is introduced into a glass cell and the color of the sample is compared with an optical filter color scale. Although it is very simple, the manual method requires good visual acuity from the operator. This procedure becomes somewhat subjective in some cases since different operators can make distinct evaluations of the same sample. In this way, this work proposes the development of a spectrophotometric analysis methodology to eliminate the subjectiveness in the determination of ASTM color of diesel oil samples by using operator-independent parameters and making quality assay more accurate and precise. Short communication. 7 refs., 2 figs., 2 tabs.

  14. Validated UV-Spectrophotometric Methods for Determination of Gemifloxacin Mesylate in Pharmaceutical Tablet Dosage Forms

    R. Rote Ambadas

    2010-01-01

    Full Text Available Two simple, economic and accurate UV spectrophotometric methods have been developed for determination of gemifloxacin mesylate in pharmaceutical tablet formulation. The first UV-spectrophotometric method depends upon the measurement of absorption at the wavelength 263.8 nm. In second area under curve method the wavelength range for detection was selected from 268.5-258.5 nm. Beer’s law was obeyed in the range of 2 to 12 μgmL-1 for both the methods. The proposed methods was validated statistically and applied successfully to determination of gemifloxacin mesylate in pharmaceutical formulation.

  15. SPECTROPHOTOMETRIC, ATOMIC ABSORPTION AND CONDUCTOMETRIC ANALYSIS OF TRAMADOL HYDROCHLORIDE

    Sara M. Anis

    2011-09-01

    Full Text Available Six simple and sensitive spectroscopic and conductometric procedures (A-F were developed for the determination of tramadol hydrochloride. Methods A, B and C are based on the reaction of cobalt (II thiocyanate with tramadol to form a stable ternary complex, which could be measured by spectrophotometric (method A, atomic absorption (method B or conductometric (method C procedures. Methods D and E depend on the reaction of molybdenum thiocyanate with tramadol to form a stable ternary complex, measured by spectrophotometric means (method D or by atomic absorption procedures (method E, while method F depends on the formation of an ion pair complex between the studied drug and bromothymol blue which is extractable into methylene chloride. Tramadol hydrochloride could be assayed in the range of 80-560 and 40-–220 μg ml-1, 1-15 mg ml-1 and 2.5-22.5, 1.25-11.25 and 5-22 μg ml-1 using methods A,B,C,D,E and F, respectively. Various experimental conditions were studied. The results obtained showed good recoveries. The proposed procedures were applied successfully to the analysis of tramadol in its pharmaceutical preparations and the results were favorably comparable with the official method.

  16. Indications of Segmental Flow in Straight Pipes by Flow Injection with Spectrophotometric Detection

    Andersen, Jens Enevold Thaulov

    2000-01-01

    A procedure of spectrophotometric analysis of fluid flow in pipes is described and its performance is tested on three different dye compounds. The procedure follows measurement and mathematical de-convolution of the signal with an exponential function that is associated with molecular diffusion. ...

  17. How Much Cranberry Juice Is in Cranberry-Apple Juice? A General Chemistry Spectrophotometric Experiment

    Edionwe, Etinosa; Villarreal, John R.; Smith, K. Christopher

    2011-01-01

    A laboratory experiment that spectrophotometrically determines the percent of cranberry juice in cranberry-apple juice is described. The experiment involves recording an absorption spectrum of cranberry juice to determine the wavelength of maximum absorption, generating a calibration curve, and measuring the absorbance of cranberry-apple juice.…

  18. Spectrophotometric study of holmium complexation in KOH solutions at 25 Deg C

    Stepanchikova, S.A.; Bitejkina, R.P.

    2006-01-01

    Complexation of Ho 3+ in solutions of HoCl 3 and KOH at 25 Deg C is studied by indicator spectrophotometric method. Within the range of pH 9.25-10.10 and μ≤4 x 10 -4 stability constants of Ho 3+ hydroxocomplexes are measured and are extrapolated on zero ion strength [ru

  19. Separation and spectrophotometric determination of elements

    Marczenko, Z.

    1986-01-01

    This book is a useful text intended as a reference for the laboratory that is either involved in spectrophotometric analysis or requires separations prior to analysis by any method. It attempts to cover a diverse series of topics in fewer than 700 pages. Part I of the book covers general topics such as separation schemes (solvent extraction, precipitation, volatility, ion exchange), principles and instrumentation used for spectrophotometry, and color reagents in only 119 pages. Entire books have been written on each of those subjects. The author must therefore resort to extensive referencing to cover each subject adequately. Part II, Methods for Separation and Determination of Individual Elements, discusses all elements - both nonmetals and metals and major procedures for the separation and spectrophotometric determination of each element are adequately covered

  20. Spectrophotometric determination of fluoride with alizarin complexone

    Marczenko, Z; Lenarczyk, L [Politechnika Warszawska (Poland)

    1976-01-01

    The modification of direct spectrophotometric method of fluoride determination by alizarin complexone has been developed. It was shown that the lanthanum alizarin complexone chelate is more convenient than that of cerium (3). The influence of acetone, dioxane and dimethyl sulphoxide in water solution on the increase of sensitivity of the method and the rate of colour reaction has been determined. The optimal pH ranges for the reaction with lanthanum and cerium (3) have been estimated. Some amines having a large molecule are useful for extraction of blue fluoride complex with isobutanol. Dioctylamine was applied in a new extraction spectrophotometric procedure of fluoride determination. Conditions in reagent have been established. Both variants of the method have been applied to the fluoride determination in several chemicals. The obtained results show a good precision and accuracy.

  1. Spectrophotometric titration of zirconium in siliceous materials

    Sugawara, K.F.; Su, Y.-S.; Strzegowski, W.R.

    1978-01-01

    An accurate and selective complexometric titration procedure based upon a spectrophotometrically detected end-point has been developed for the determination of zirconium in glasses, glass-ceramics and refractories. A p-bromomandelic acid separation step for zirconium imparts excellent selectivity to the procedure. The method is particularly important for the 1 to 5% concentration range where a simple, accurate and selective method for the determination of zirconium has been lacking. (author)

  2. [Spectrophotometric and HPLC evaluation of ceftazidime stability].

    Palade, B; Cioroiu, B; Lazăr, Doina; Corciovă, Andreia; Lazăr, M I

    2010-01-01

    In this paper we followed up the stability of ceftazidime, raw material used in drug industry. Matherials and methods: We used three spectrophotometric methods based on ceftazidime property to form complexes with p-chloranilic acid (ac. p-CA), 3-methylbenzothiazolin-2-on hydrazone (MBTH) and N-(1-naphtil) etilendiamine (NEDA) and a chromatographic method (HPLC). Our results revealed that the substances analyzed maintained minimum content allowable.

  3. Compatible validated spectrofluorimetric and spectrophotometric methods for determination of vildagliptin and saxagliptin by factorial design experiments

    Abdel-Aziz, Omar; Ayad, Miriam F.; Tadros, Mariam M.

    2015-04-01

    Simple, selective and reproducible spectrofluorimetric and spectrophotometric methods have been developed for the determination of vildagliptin and saxagliptin in bulk and their pharmaceutical dosage forms. The first proposed spectrofluorimetric method is based on the dansylation reaction of the amino group of vildagliptin with dansyl chloride to form a highly fluorescent product. The formed product was measured spectrofluorimetrically at 455 nm after excitation at 345 nm. Beer's law was obeyed in a concentration range of 100-600 μg ml-1. The second proposed spectrophotometric method is based on the charge transfer complex of saxagliptin with tetrachloro-1,4-benzoquinone (p-chloranil). The formed charge transfer complex was measured spectrophotometrically at 530 nm. Beer's law was obeyed in a concentration range of 100-850 μg ml-1. The third proposed spectrophotometric method is based on the condensation reaction of the primary amino group of saxagliptin with formaldehyde and acetyl acetone to form a yellow colored product known as Hantzsch reaction, measured at 342.5 nm. Beer's law was obeyed in a concentration range of 50-300 μg ml-1. All the variables were studied to optimize the reactions' conditions using factorial design. The developed methods were validated and proved to be specific and accurate for quality control of vildagliptin and saxagliptin in their pharmaceutical dosage forms.

  4. Kinetic Spectrophotometric Determination of Certain Cephalosporins in Pharmaceutical Formulations

    Mahmoud A. Omar

    2009-01-01

    Full Text Available A simple, reliable, and sensitive kinetic spectrophotometric method was developed for determination of eight cephalosporin antibiotics, namely, Cefotaxime sodium, Cephapirin sodium, Cephradine dihydrate, Cephalexin monohydrate, Ceftazidime pentahydrate, Cefazoline sodium, Ceftriaxone sodium, and Cefuroxime sodium. The method depends on oxidation of each of studied drugs with alkaline potassium permanganate. The reaction is followed spectrophotometrically by measuring the rate of change of absorbance at 610 nm. The initial rate and fixed time (at 3 minutes methods are utilized for construction of calibration graphs to determine the concentration of the studied drugs. The calibration graphs are linear in the concentration ranges 5–15 g mL−1 and 5–25 g mL−1 using the initial rate and fixed time methods, respectively. The results are validated statistically and checked through recovery studies. The method has been successfully applied for the determination of the studied cephalosporins in commercial dosage forms. Statistical comparisons of the results with the reference methods show the excellent agreement and indicate no significant difference in accuracy and precision.

  5. AAS and spectrophotometric determination of propranolol HCl and metoprolol tartrate.

    El-Ries, M A; Abou Attia, F M; Ibrahim, S A

    2000-12-15

    Two simple and accurate spectrophotometric methods are described for the determination of propranolol hydrochloride (I) and metoprolol tartrate (II). The methods are based on the reaction of each drug as a secondary amine: (a) with carbon disulphide, the formed complex extracted into iso-butyl methyl ketone (IBMK) after chelation with Cu(II) ions at pH 7.5, followed by measuring the absorbance at 435.4 nm or indirectly for the drug by flame atomic absorption spectrophotometry (AAS). The calibration graph is linear up to 40 and 60 microg ml(-1) with apparent molar absorptivities of 6.89 x 10(3) and 1.08 x 104 l mol(-1) cm(-1) and correlation coefficients of 0.9994 and 0.9995 for propranolol and metoprolol, respectively; (b) with pi-acceptors, tetracyanoethylene (TCNE), or chloranilic acid (CLA) to give highly coloured complex species. The coloured products are quantitated spectrophotometrically at 415 or 510 nm for the two drugs with TCNE and CLA, respectively, and obey Beer's Law with RSD less than 2.0. The methods were applied to the determination of these drugs in pharmaceutical preparation without interferences.

  6. KINETIC SPECTROPHOTOMETRIC DETERMINATION OF SOME ...

    Preferred Customer

    parameters affecting the development and stability of the colors were carefully studied and .... 100 mL with double distilled water in a 100 mL measuring flask. ... by measuring the slope of the tangent to the absorbance-time curve. ... The effect of the KMnO4 concentration on the initial rate of the reaction (ν) was studied using.

  7. Integrating fMRI with psychophysiological measurements in the study of decision-making

    Wong, Savio W.H.; Xue, Gui; Bechara, Antoine

    2011-01-01

    Neuroimaging techniques have recently been used to examine the neural mechanism of decision-making. Nevertheless, most of the neuroimaging studies overlook the importance of emotion and autonomic response in modulating the process of decision-making. In this paper, we discussed how to integrating fMRI with psychophysiological measurements in studying decision-making. We suggested that psychophysiological data would complement with fMRI findings in providing a more comprehensive understanding ...

  8. Individual v. community-level measures of women's decision-making ...

    Individual v. community-level measures of women's decision-making involvement and ... participation for child survival in sub-Saharan Africa is limited. ... Multilevel discrete-time hazard models were employed to investigate the net effect of ...

  9. Make-or-buy decisions and the manipulability of performance measures

    Andersson, Fredrik

    2009-01-01

    Abstract in Undetermined The make-or-buy decision is analyzed in a simple framework combining contractual incompleteness with the existence of an imperfect but contractible performance measure. Contractual incompleteness gives rise to two regimes, identified with make and buy. The performance measure on which comprehensive contracts can be written is imperfect in the sense of being subject to manipulation. The performance incentives faced by the agent are stronger in the “buy” regime. A posit...

  10. Validation of a spectrophotometric method for quantification of carboxyhemoglobin.

    Luchini, Paulo D; Leyton, Jaime F; Strombech, Maria de Lourdes C; Ponce, Julio C; Jesus, Maria das Graças S; Leyton, Vilma

    2009-10-01

    The measurement of carboxyhemoglobin (COHb) levels in blood is a valuable procedure to confirm exposure to carbon monoxide (CO) either for forensic or occupational matters. A previously described method using spectrophotometric readings at 420 and 432 nm after reduction of oxyhemoglobin (O(2)Hb) and methemoglobin with sodium hydrosulfite solution leads to an exponential curve. This curve, used with pre-established factors, serves well for lower concentrations (1-7%) or for high concentrations (> 20%) but very rarely for both. The authors have observed that small variations on the previously described factors F1, F2, and F3, obtained from readings for 100% COHb and 100% O(2)Hb, turn into significant changes in COHb% results and propose that these factors should be determined every time COHb is measured by reading CO and O(2) saturated samples. This practice leads to an increase in accuracy and precision.

  11. Determination of rhenium (7) trace amounts by spectrophotometric titration in medium of mixed solvents

    Kuznetsov, V.V.; Samorukova, O.L.

    1978-01-01

    The method has been proposed of determining rhenium (7) microamounts by spectrophotometric titration in the medium water-dimethyl-sulphoxide with the reagent nitrochromazo. The method is based on the formation of ionic pairs K + ReO 4 - in water-organic solvents. The results of rhenium determination are satisfactory in a wide concentration range up to 0.3 mkg in 15 ml which makes the method proposed close in sensitivity to photometric methods and much better in reproducibility

  12. Purohit's spectrophotometric method for determination of stability constants of complexes using Job's curves

    Purohit, D.N.; Goswami, A.K.; Chauhan, R.S.; Ressalan, S.

    1999-01-01

    A spectrophotometric method for determination of stability constants making use of Job's curves has been developed. Using this method stability constants of Zn(II), Cd(II), Mo(VI) and V(V) complexes of hydroxytriazenes have been determined. For the sake of comparison, values of the stability constants were also determined using Harvey and Manning's method. The values of the stability constants developed by two methods compare well. This new method has been named as Purohit's method. (author)

  13. Development of a safety decision-making scenario to measure worker safety in agriculture.

    Mosher, G A; Keren, N; Freeman, S A; Hurburgh, C R

    2014-04-01

    Human factors play an important role in the management of occupational safety, especially in high-hazard workplaces such as commercial grain-handling facilities. Employee decision-making patterns represent an essential component of the safety system within a work environment. This research describes the process used to create a safety decision-making scenario to measure the process that grain-handling employees used to make choices in a safety-related work task. A sample of 160 employees completed safety decision-making simulations based on a hypothetical but realistic scenario in a grain-handling environment. Their choices and the information they used to make their choices were recorded. Although the employees emphasized safety information in their decision-making process, not all of their choices were safe choices. Factors influencing their choices are discussed, and implications for industry, management, and workers are shared.

  14. Determination of the acidity constants of neutral red and bromocresol green by solution scanometric method and comparison with spectrophotometric results

    Ardeshir Shokrollahi

    2016-03-01

    The method is based on scanning cells containing the indicator solution with a scanner, and analyzing the color of each cell with a software written in visual basic (VB 6 media to red, green and blue values. The cells were made by making holes in the Plexiglas® sheet. Also, the acidity constants of the neutral red and bromocresol green indicators were studied with spectrophotometrically. HypSpec program has been applied for the estimation of pKa values based on spectrophotometric data. The agreement between obtained pKa values by solution scanometric, spectrophotometric method and values reported in the literature demonstrates the utility of the method here used. Also the HySS 2009 program was applied for drawing of the corresponding distribution diagrams.

  15. Kinetic Spectrophotometric Determination of Trace Amounts of Sulfide

    Barzegar, Mohsen [Tarbiat Modarres University, Tehran (Iran, Islamic Republic of); Jabbari, Ali [K. N. Toosi University, Tehran (Iran, Islamic Republic of); Esmaeili, Majid [Razi University, Kermanshah (Iran, Islamic Republic of)

    2003-09-15

    A method for the determination of trace amount of sulfide based on the addition reaction of sulfide with methyl green at pH 7.5 and 25 .deg. C is described. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of the dyestuff at 637 nm by the initial rate and fixed time method. The calibration graph is linear in the range 30-1200 ppb. The theoretical limit of detection was 0.014 ppm. Seven replicate analysis of a sample solution containing 0.70 ppm sulfide gave a relative standard deviation of 1.5%. The interfering effects of various ions on sulfide determination have been reported and procedures for removal of interference have been described. The proposed method was applied successfully to the determination of sulfide in tap and wastewater samples.

  16. Kinetic Spectrophotometric Determination of Trace Amounts of Sulfide

    Barzegar, Mohsen; Jabbari, Ali; Esmaeili, Majid

    2003-01-01

    A method for the determination of trace amount of sulfide based on the addition reaction of sulfide with methyl green at pH 7.5 and 25 .deg. C is described. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of the dyestuff at 637 nm by the initial rate and fixed time method. The calibration graph is linear in the range 30-1200 ppb. The theoretical limit of detection was 0.014 ppm. Seven replicate analysis of a sample solution containing 0.70 ppm sulfide gave a relative standard deviation of 1.5%. The interfering effects of various ions on sulfide determination have been reported and procedures for removal of interference have been described. The proposed method was applied successfully to the determination of sulfide in tap and wastewater samples

  17. DLLME-spectrophotometric determination of glyphosate residue in legumes.

    Çetin, Emine; Şahan, Serkan; Ülgen, Ahmet; Şahin, Uğur

    2017-09-01

    A new separation and pre-concentration method for spectrophotometric determination of glyphosate herbicide was developed. Glyphosate was converted into dithiocarbamic acid with CS 2 , followed by copper in the presence of ammonia to promote complex formation. This complex was collected in a CH 2 Cl 2 organic drop and absorbance measured at 435nm. The analytical parameters, such as the amount of NH 3 , Cu(II) and CS 2 , type of extraction solutions, and the ratio of dispersive and organic liquids were optimized. The calibration curve was linear in the range 0.5-10mgl -1 . The limits of detection and quantification were calculated from 3s to 10s criterions as 0.21mgl -1 and 0.70mgl -1 , respectively. The developed method was applied to legume samples with the satisfactory recovery values of 98±4-102±3%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Speciation and spectrophotometric determination of uranium in seawater

    M. KONSTANTINOU

    2004-06-01

    Full Text Available A series of ion-exchange and extraction procedures for the separation of uranium from seawater samples and subsequent spectrophotometric determination of uranium in seawater by means of arsenazo(III is described. According to the measurements performed by means of traced samples at every stage of separation, the yield of the pre-analytical procedures is generally over 90% and the separation of uranium very selective. The mean uranium concentration in seawater samples collected from five different coastal areas in Cyprus was found to be 3.2 ± 0.2 & micro; g L-1. Uranium in seawater is stable in its hexavalent oxidation state and UO2 (CO334- is the predominant species under normal coastal conditions (pH ≥ 8, EH ≥ 0.35 mV, 1 atm and 0.03% CO2.

  19. Spectrophotometric determination of the sulfhydryl containing drug mesna

    Rim S. Haggag

    2016-06-01

    Full Text Available Four simple and sensitive spectrophotometric methods were developed for the determination of the sulfhydryl containing drug mesna (MSN. Methods I and II rely on nucleophilic aromatic substitution reactions using two UV tagging reagents namely: 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl for method I and 2,4-dinitrofluorobenzene (DNFB for method II. Both reactions took place in alkaline buffered medium and the obtained yellowish products were measured at 414 and 332 nm for methods I and II, respectively. Methods III and IV are indirect spectrophotometric methods based on the suppressive effect of MSN on the absorption of two ternary complex systems which are composed of 1,10-phenanthroline, silver and eosin for method III and 1,10-phenanthroline, silver and bromopyrogallol red for method IV. The decrease in absorbance of the ternary complexes was measured at 547 and 635 nm for methods III and IV, respectively. All the experimental parameters affecting these reactions were carefully studied and optimized. The methods were validated as per the ICH guidelines. The methods were applicable in the linearity ranges 4–18 μg/mL for method I, 4–16 μg/mL for method II, 0.25–2.25 μg/mL for method III and 0.25–1.75 μg/mL for method IV. The proposed methods were successfully applied for the analysis of MSN in its commercial ampoules and no interference was encountered from the present excipients as indicated by the satisfactory percentage recoveries. The results obtained were in a good agreement with those obtained from a previously published method of the investigated drug.

  20. Comparison of spectrophotometric and radioisotopic methods for the assay of Rubisco in ozone-treated plants

    Reid, C.D.; Tissue, D.T.; Fiscus, E.L.; Strain, B.R.

    1997-01-01

    Radioisotopic and spectrophotometric assays for ribulose-1,5-bisphosphate carboxylase/oxygenase (Rubisco) initial and final activities and Rubisco content were compared in plants chronically exposed to ozone (O 3 ) in a greenhouse and the field. In a greenhouse experiment, Glycine max was treated in exposure chambers with either charcoal-filtered air (CF air) or 100 nl O 3 l -1 for 6 h daily during vegetative growth. Samples were collected after 7 days of exposure. In a field experiment, G. max was treated in open-top chambers with either CF air or non-filtered air with O 3 added at 1.5 times ambient O 3 for 12 h daily. Average daily O 3 concentrations were 21 and 92 nl l -1 in the CF and O 3 treatments, respectively. Samples were collected during vegetative and reproductive growth. Both assays generally yielded comparable Rubisco initial and final activities for greenhouse-grown plants regardless of the O 3 treatment. However for field-grown plants, Rubisco initial and final activities average 15 and 23% lower when assayed by the spectrophotometric rather than the radioisotopic method. For Rubisco content estimated by the spectrophotometric method, lower values for the regression of Rubisco activity vs concentration of carboxyarabinitol-1.5-bisphosphate were observed in O 3- than in CF-treated plants. Both assays yielded comparable Rubisco contents in the greenhouse and in the field although the variation was larger with the spectrophotometric method in field-grown plants. Growth conditions, field vs greenhouse, were more critical to the spectrophotometric assay performance than the O 3 treatments for measurement of Rubisco activity and content. (au) 40 refs

  1. Development of a Draft Core Set of Domains for Measuring Shared Decision Making in Osteoarthritis

    Toupin-April, Karine; Barton, Jennifer; Fraenkel, Liana

    2015-01-01

    OBJECTIVE: Despite the importance of shared decision making for delivering patient-centered care in rheumatology, there is no consensus on how to measure its process and outcomes. The aim of this Outcome Measures in Rheumatology (OMERACT) working group is to determine the core set of domains...... for measuring shared decision making in intervention studies in adults with osteoarthritis (OA), from the perspectives of patients, health professionals, and researchers. METHODS: We followed the OMERACT Filter 2.0 method to develop a draft core domain set by (1) forming an OMERACT working group; (2) conducting...... a review of domains of shared decision making; and (3) obtaining opinions of all those involved using a modified nominal group process held at a session activity at the OMERACT 12 meeting. RESULTS: In all, 26 people from Europe, North America, and Australia, including 5 patient research partners...

  2. Spectrophotometric characterization of hemozoin as a malaria biomarker

    Silva, Ivo; Lima, Rui; Minas, Graça.; Catarino, Susana O.

    2017-08-01

    Malaria is a parasitic disease with more than a billion people worldwide at risk of contraction. The disease is predominantly widespread in regions with precarious healthcare conditions and resources. Despite the several available malaria diagnostic methods, only two are predominantly used in the field in malaria-endemic countries: microscopy and rapid diagnostic tests. In this work, an alternative diagnostic system is proposed, based on optical absorption spectrophotometry. The main objective of this paper is the spectrophotometric study of hemozoin as a malaria biomarker, since it is a sub-product of the malaria infection. The optical absorbance of hemoglobin and hemozoin solutions in purified water was measured in the visible spectrum range using a spectrophotometric setup. The results showed main absorbance peaks at 540 nm and 574 nm for hemoglobin, and at 672 nm for hemozoin. The tests performed in aqueous solutions have shown that both hemoglobin and synthetic hemozoin, when alone in solution, were detected by absorbance, with sensitivity of 0.05 g/L, and with a high linearity (R2> 0.92 for all wavelength peaks). Furthermore, it was found that the whole blood and the hemoglobin spectra have similar absorption peaks. By combining whole blood and synthetic hemozoin solutions, it was proved that both the hemozoin and the hemoglobin absorbance peaks could still be detected by spectrophotometry. For instance, in polydimethylsiloxane wells, the proposed method was able to detect hemozoin in whole blood samples for optical paths as low as 3 mm in cylindrical wells, thus proving the capability for this method's miniaturization. With this work, it is possible to conclude that hemozoin is a viable candidate as a biomarker for malaria detection by optical absorption spectrophotometry and also, that an autonomous, fully integrated and low cost miniaturized system, based on such a principle, could provide an efficient diagnosis of malaria.

  3. Decision-making impairment in obsessive-compulsive disorder as measured by the Iowa Gambling Task

    Felipe Filardi da Rocha

    2011-08-01

    Full Text Available OBJECTIVE: This study aims to evaluate the process of decision-making in patients with obsessive-compulsive disorder (OCD using the Iowa Gambling Task (IGT. In addition, we intend to expand the understanding of clinical and demographic characteristics that influence decision-making. METHOD: Our sample consisted of 214 subjects (107 diagnosed with OCD and 107 healthy controls who were evaluated on their clinical, demographic and neuropsychological features. Moreover, the Iowa Gambling Task (IGT, a task that detects and measures decision-making impairments, was used. RESULTS: We found that OCD patients performed significantly worse on the IGT. Furthermore, features such as symptoms of anxiety did not influence IGT performance. CONCLUSION: Impaired decision-making seems to be a key feature of OCD. Given that OCD is a complex heterogeneous disorder, homogeneous groups are necessary for an accurate characterization of our findings.

  4. New Spectrophotometric and Conductometric Methods for Macrolide Antibiotics Determination in Pure and Pharmaceutical Dosage Forms Using Rose Bengal

    Rania A. Sayed

    2013-01-01

    Full Text Available Two Simple, accurate, precise, and rapid spectrophotometric and conductometric methods were developed for the estimation of erythromycin thiocyanate (I, clarithromycin (II, and azithromycin dihydrate (III in both pure and pharmaceutical dosage forms. The spectrophotometric procedure depends on the reaction of rose bengal and copper with the cited drugs to form stable ternary complexes which are extractable with methylene chloride, and the absorbances were measured at 558, 557, and 560 nm for (I, (II, and (III, respectively. The conductometric method depends on the formation of an ion-pair complex between the studied drug and rose bengal. For the spectrophotometric method, Beer's law was obeyed. The correlation coefficient ( for the studied drugs was found to be 0.9999. The molar absorptivity (, Sandell’s sensitivity, limit of detection (LOD, and limit of quantification (LOQ were also calculated. The proposed methods were successfully applied for the determination of certain pharmaceutical dosage forms containing the studied drugs

  5. Spectrophotometric determination of trace uranium in phosphate ore samples from kurum and uro areas, Nuba mountains, Sudan

    Mohamed, A. A.; Ali, A. H.; Altayeb, M. A. H.

    2004-01-01

    A method was proposed for the spectrophotometric determination of uranium content in phosphate ores. the method is based on the use of nitrogen (v) acid for leaching the rock, and treatment with ammonium carbonate solution, whereby uranium (Vi) is kept in solution as its carbonate complex. The ion-exchange technique was used for the recovery of uranium. Uranium was determined spectrophotometrically by measurement of the absorbance of the yellow uranium (Vi)-8-hydroxyquinolate complex at λ 425 nm. The procedure was used for the determination of trace uranium content in 30 phosphate ore samples collected from Kurun and Uro areas in Nuba mountains in Sudan. X-ray fluorescence technique was employed for the assessment of the method used. The spectrophotometric method results show a high similarity with those obtained by XRF technique. This agreement indicates that the procedure proposed here has been successfully applied for the determination of uranium in phosphate ores. (Author)

  6. Spectrophotometric methods for determining noble metals

    Gur'eva, R.F.; Savvin, S.B.

    2002-01-01

    The main trends of the development of spectrophotometric methods for determining noble metals (NMs) including ruthenium are considered. One of these trends is the synthesis and study of new, highly sensitive and selective organic reagents for determining NMs in solutions and solid phase. Another trend is the search for and developing of new methodological approaches (techniques) and color reactions, including those that involve modified and immobilized reagents. The third trend includes the improvement of equipment and automation. It is shown that the present-day spectrophotometry can provide the determination of NMs in samples with concentrations from several to 10 -4 % (photometry and differential photometry) and down to 10 -7 % (test and sorption-spectroscopic methods based on photometry and diffuse-reflectance spectroscopy, including the use of chromaticity functions) [ru

  7. Spectrophotometric determination of plutonium with chlorophosphonazo III in n-pentanol

    Saponara, N.M.; Marsh, S.F.

    1982-03-01

    Microgram amounts of plutonium are measured spectrophotometrically as the plutonium-chlorophosphonazo III complex after extraction into n-pentanol from 1.5 M HCl. The relative standard deviation is 1.5% for the range of 2.5 to 17.5 μg. The tolerance is excellent for many metals and nonmetals present in nuclear fuel-cycle materials. A preceding anion-exchange-column separation increases tolerance for certain metals and nonmetals

  8. Spectrophotometric studies of transcurium element halides and oxyhalides in the solid state

    Young, J.P.; Haire, R.G.; Fellows, R. L.; Peterson, J.R.

    1978-01-01

    The present state of a microscale spectrophotometric technique is described. The application of spectrophotometry to transcurium elements (Bk, Cf, Es) requires some rather specialized microtechniques for the following reasons: only small amounts of these elements are available; their radioactivity makes the use of μg-sized samples desirable; and spectral study of solids requires thin samples. A schematic diagram of the microscope-spectrophotometer used for spectrophotometric study of the transcurium element compounds is shown. The spectrophotometer, of local design, consists of two microscopes equipped with Cassegrainian reflecting microscope objective lenses, a quartz field lens, and a Jarrell Ash 1/2 meter scanning monochromator equipped with a 1180 line/mm grating blazed at 4000 A. The photomultiplier used in this system is an S-1 type RCA 7102 operated at approximately -50 deg C. This grating-photomultiplier combination provides a continuous response free of discontinuities over the useful wavelength range of the system from 3000 to 11 000 A. The microscope-spectrophotometer is a single beam instrument. Each spectral trace is registered as photomultiplier current on a strip chart recorder. In order to obtain true absorption spectra, however, the output from the photometer is also simultaneously digitized for on-line processing. The unique advantages of applying both spectrophotometric and X-ray powder diffraction methods on the sample, in order to identify and characterize newly synthesized compounds, are also discussed. (T.G.)

  9. Zeolite - a possible substitute of silica gel in spectrophotometric determination of uranium?

    Foeldesova, M; Dillinger, P.

    2006-01-01

    Zeolites sorption abilities differ from the ones of the silica gel, which is normally used for uranium determination by spectrophotometric method. The difference is obvious mainly in the case of zeolites chemically modified with 1 or 2 mol/L NaOH solution. Absorbances measured using these zeolites on an radioactive water samples were 4 to 4.2 times bigger than the ones with silica gel. This avoids a use of one universal calibration curve for experimental data evaluation. Within delivered experimental data only a calibration curve for silica gel was provided. Its application to zeolites caused substantial misinterpretation of the results. Calculational construction of individual calibration curves made at this work shaw, that zeolites have a potential to replace the silica gel. This possibility is necessary to confirm by more experiments. Better sorption abilities of the modified zeolites would be utilized to reduce the lower limit for uranium determination by spectrophotometric method. (authors)

  10. Spectrophotometric Determination of Cilostazol in Tablet Dosage Form

    Erah

    Purpose: To develop simple, rapid and selective spectrophotometric methods for ... Conclusion: These validated methods may be useful for routine analysis of cilostazol ... Keywords: Cilostazol tablets, UV spectrophotometry, Linear regression ...

  11. Study on the Solid Phase Extraction and Spectrophotometric ...

    NJD

    Spectrophotometric Determination of Mercury in Water and. Biological ... 1Department of Chemistry, Yunnan University, Kunming, 650091, P.R. China. 2Department of ... (such as higher enrichment factor, reduced contamination of the.

  12. Spectrophotometric and Voltammetric Studies on the Interaction of ...

    0.84V(vs. SCE) also changed correspondingly without change of the peak potential, which also indicated that the binding reaction had taken place. Under the selected conditions a new spectrophotometric analytical method was established for ...

  13. An experimental method for making spectral emittance and surface temperature measurements of opaque surfaces

    Moore, Travis J.; Jones, Matthew R.; Tree, Dale R.; Daniel Maynes, R.; Baxter, Larry L.

    2011-01-01

    An experimental procedure has been developed to make spectral emittance and temperature measurements. The spectral emittance of an object is calculated using measurements of the spectral emissive power and of the surface temperature of the object obtained using a Fourier transform infrared (FTIR) spectrometer. A calibration procedure is described in detail which accounts for the temperature dependence of the detector. The methods used to extract the spectral emissive power and surface temperature from measured infrared spectra were validated using a blackbody radiator at known temperatures. The average error in the measured spectral emittance was 2.1% and the average difference between the temperature inferred from the recorded spectra and the temperature indicated on the blackbody radiator was 1.2%. The method was used to measure the spectral emittance of oxidized copper at various temperatures.

  14. Dose intercomparison for 400–500 keV electrons using FWT-60 film and glutamine (spectrophotometric readout) dosimeters

    Gupta, B. L.; Nilekani, S. R.; Gehringer, P.

    1986-01-01

    This paper describes the dose and the depth dose measurements with FWT-60 film and glutamine (Spectrophotometric readout) dosimeters for 400–500 keV electrons. The glutamine powder was spread uniformly in polyethylene bags and the powder thickness in each bag was 5 mg cm−2. Both techniques show...

  15. Measuring patient participation in surgical treatment decision-making from healthcare professionals' perspective.

    Heggland, Liv-Helen; Mikkelsen, Aslaug; Øgaard, Torvald; Hausken, Kjell

    2014-02-01

    To develop, empirical test, and validate an instrument measuring patient participation in surgical treatment decision-making from healthcare professionals' perspective. Since the advent of New Public Management in many Western countries, patient participation in healthcare decision-making has been considered to be a best practice. A common notion is that well-educated and well-informed public want to choose their own treatments and providers and want to ask questions about the quality of their health services. Survey. A self-report-measuring instrument was designed and administered to 620 healthcare professionals. Items were developed, validated and tested by 451 nurses and physicians working in six surgical wards in a University Hospital in Norway. A 16-item scale with the following four dimensions was developed: information dissemination, formulation of options, integration of information and control. Factor analysis procedures and reliability testing were performed. A one-way, between-groups analysis of variance was conducted to compare doctors' and nurses' opinions on four dimensions of patient participation in surgical treatment decision-making. This article shows that patient participation in surgical treatment decision-making can be measured by a 16-item scale and four distinct dimensions. The analysis demonstrated a reasonable level of construct validity and reliability. Nurses and physicians have a positive attitude towards patient participation overall, but the two groups differ in the extent to which they accept the idea of patient participation in treatment decision-making. The instrument can be a tool for managers and healthcare professionals in the implementation of patient participation in clinical practice. Data from the instrument can be useful to identify health services being provided and what areas that could strengthen patient participation. © 2013 Blackwell Publishing Ltd.

  16. Physics and Analysis at a Hadron Collider - Making Measurements (3/3)

    CERN. Geneva

    2010-01-01

    This is the third lecture of three which together discuss the physics of hadron colliders with an emphasis on experimental techniques used for data analysis. This third lecture discusses techniques important for analyses making a measurement (e.g. determining a cross section or a particle property such as its mass or lifetime) using some CDF top-quark analyses as specific examples. The lectures are aimed at graduate students.

  17. Spectrophotometric determination of some metal ions using hydrazones

    Mohammed, M. S.

    2000-05-01

    In this research many starting materials were prepared, like methyl salicylate and salicylic acid hydrazide from which different derivatives of hydrazones were synthesized by coupling with carbonyl compounds like benzil monoxime and benzil mono hydrazone which are prepared and others like salicylaldehyde and benzoin. The hydrazones that were synthesized are salicylaldehyde salicylic acid hydrazone, benzoin salicylic acid hydrazone, benzil mono hydrazone salicylic acid hydrazone and benzil monoxime salicylic acid hydrazone. These reagents were determined by different methods, IR spectrophotometric determination, the nitrogen content method and melting point determination. These hydrazones act as ligands for determination of some metal ions by making different coloured complexes that were prepared for eight hydrazones with eight metal ions U (VI), Fe (II), Fe (III), Co (II), V (II), Mo (VI), Ni (II) and Cu (II). These complexes were determined by ultraviolet and visible spectrophotometer (UV/VIS) to detect their absorbance and wavelengths (λ max). The two hydrazones salicylaldehyde salicylic acid-hydrazone and benzoin salicylic acid hydrazone, were selected for determination of five metal ions (Fe (II), Fe (III), U (VI), Ni (II) and Cu (II)), using two micelles sodium n-dodecyl sulphate and pyridinium hexa decyl bromide mono hydrate. Their absorbance and wavelengths were detected using UV/VIS spectrophotometer. (Author)

  18. The four principles: can they be measured and do they predict ethical decision making?

    Page, Katie

    2012-05-20

    The four principles of Beauchamp and Childress--autonomy, non-maleficence, beneficence and justice--have been extremely influential in the field of medical ethics, and are fundamental for understanding the current approach to ethical assessment in health care. This study tests whether these principles can be quantitatively measured on an individual level, and then subsequently if they are used in the decision making process when individuals are faced with ethical dilemmas. The Analytic Hierarchy Process was used as a tool for the measurement of the principles. Four scenarios, which involved conflicts between the medical ethical principles, were presented to participants who then made judgments about the ethicality of the action in the scenario, and their intentions to act in the same manner if they were in the situation. Individual preferences for these medical ethical principles can be measured using the Analytic Hierarchy Process. This technique provides a useful tool in which to highlight individual medical ethical values. On average, individuals have a significant preference for non-maleficence over the other principles, however, and perhaps counter-intuitively, this preference does not seem to relate to applied ethical judgements in specific ethical dilemmas. People state they value these medical ethical principles but they do not actually seem to use them directly in the decision making process. The reasons for this are explained through the lack of a behavioural model to account for the relevant situational factors not captured by the principles. The limitations of the principles in predicting ethical decision making are discussed.

  19. What to measure next to improve decision making? On top-down task driven feature saliency

    Hansen, Lars Kai; Karadogan, Seliz; Marchegiani, Letizia

    2011-01-01

    Top-down attention is modeled as decision making based on incomplete information. We consider decisions made in a sequential measurement situation where initially only an incomplete input feature vector is available, however, where we are given the possibility to acquire additional input values...... among the missing features. The procecure thus poses the question what to do next? We take an information theoretical approach implemented for generality in a generative mixture model. The framework allows us reduce the decision about what to measure next in a classification problem to the estimation...

  20. Moving towards tangible decision-making tools for policy makers: Measuring and monitoring energy access provision

    Bhanot, Jaya; Jha, Vivek

    2012-01-01

    Access to energy services has been recognised as central to achieving economic growth and sustainable development. However, almost 1.3 billion people in the world still lack access to electricity and 2.7 billion lack access to clean cooking facilities. In this backdrop, the issue of energy access is receiving more interest than ever before and this has brought to the fore, the need for a robust decision support tool for policy makers to measure the progress of energy access provision and also to provide direction for future policy making. The paper studies existing definitions of energy access and identifies the key requirements for an appropriate decision-making tool to measure and monitor energy access provision. In this context the paper assesses the strengths and weaknesses of the metrics currently being used to measure energy access in policy, as well as of contemporary monitoring and evaluation frameworks being used in other sectors. Based on these insights, a dashboard of indicators is proposed as an alternate decision support tool for policy makers to measure energy access. The paper concludes with a discussion on what is needed to operationalise this proposed framework. - Highlights: ► No one indicator or metric can successfully capture progress on energy access. ► A service oriented approach is necessary to measure energy access. ► Socio-economic and political contexts influence success of energy access policies.

  1. Development of a Draft Core Set of Domains for Measuring Shared Decision Making in Osteoarthritis: An OMERACT Working Group on Shared Decision Making.

    Toupin-April, Karine; Barton, Jennifer; Fraenkel, Liana; Li, Linda; Grandpierre, Viviane; Guillemin, Francis; Rader, Tamara; Stacey, Dawn; Légaré, France; Jull, Janet; Petkovic, Jennifer; Scholte-Voshaar, Marieke; Welch, Vivian; Lyddiatt, Anne; Hofstetter, Cathie; De Wit, Maarten; March, Lyn; Meade, Tanya; Christensen, Robin; Gaujoux-Viala, Cécile; Suarez-Almazor, Maria E; Boonen, Annelies; Pohl, Christoph; Martin, Richard; Tugwell, Peter S

    2015-12-01

    Despite the importance of shared decision making for delivering patient-centered care in rheumatology, there is no consensus on how to measure its process and outcomes. The aim of this Outcome Measures in Rheumatology (OMERACT) working group is to determine the core set of domains for measuring shared decision making in intervention studies in adults with osteoarthritis (OA), from the perspectives of patients, health professionals, and researchers. We followed the OMERACT Filter 2.0 method to develop a draft core domain set by (1) forming an OMERACT working group; (2) conducting a review of domains of shared decision making; and (3) obtaining opinions of all those involved using a modified nominal group process held at a session activity at the OMERACT 12 meeting. In all, 26 people from Europe, North America, and Australia, including 5 patient research partners, participated in the session activity. Participants identified the following domains for measuring shared decision making to be included as part of the draft core set: (1) identifying the decision, (2) exchanging information, (3) clarifying views, (4) deliberating, (5) making the decision, (6) putting the decision into practice, and (7) assessing the effect of the decision. Contextual factors were also suggested. We proposed a draft core set of shared decision-making domains for OA intervention research studies. Next steps include a workshop at OMERACT 13 to reach consensus on these proposed domains in the wider OMERACT group, as well as to detail subdomains and assess instruments to develop a core outcome measurement set.

  2. Decision Dissonance: Evaluating an Approach to Measuring the Quality of Surgical Decision Making

    Fowler, Floyd J.; Gallagher, Patricia M.; Drake, Keith M.; Sepucha, Karen R.

    2013-01-01

    Background Good decision making has been increasingly cited as a core component of good medical care, and shared decision making is one means of achieving high decision quality. If it is to be a standard, good measures and protocols are needed for assessing the quality of decisions. Consistency with patient goals and concerns is one defining characteristic of a good decision. A new method for evaluating decision quality for major surgical decisions was examined, and a methodology for collecting the needed data was developed. Methods For a national probability sample of fee-for-service Medicare beneficiaries who had a coronary artery bypass graft (CABG), a lumpectomy or a mastectomy for breast cancer, or surgery for prostate cancer during the last half of 2008, a mail survey of selected patients was carried out about one year after the procedures. Patients’ goals and concerns, knowledge, key aspects of interactions with clinicians, and feelings about the decisions were assessed. A Decision Dissonance Score was created that measured the extent to which patient ratings of goals ran counter to the treatment received. The construct and predictive validity of the Decision Dissonance Score was then assessed. Results When data were averaged across all four procedures, patients with more knowledge and those who reported more involvement reported significantly lower Decision Dissonance Scores. Patients with lower Decision Dissonance Scores also reported more confidence in their decisions and feeling more positively about how the treatment turned out, and they were more likely to say that they would make the same decision again. Conclusions Surveying discharged surgery patients is a feasible way to evaluate decision making, and Decision Dissonance appears to be a promising approach to validly measuring decision quality. PMID:23516764

  3. Simultaneous spectrophotometric determination of tungsten and molybdenum with dithiol

    Navale, A.S.

    1987-01-01

    Toluene-3,4-dithiol is a very sensitive reagent for the spectrophotometric determination of tungsten and molybdenum. Since the absorption spectra of the dithiol complexes of these two elements overlap, a separation of the two elements is carried out. This leads to time consuming extraction procedures. Measuring the absorption of the mixed complexes at two wavelengths and solving a set of simultaneous equations is also not favorable because a lot of time and effort is required for solving the simultaneous equations for each sample. A faster and simpler method is described here for the simultaneous determination of the two elements. The method is based on measurement of absorbance of the mixed complexes at three pre-selected wavelengths and simple calculations involving the absorbance differences. The criteria for selecting the three wavelengths and the theory are described. Application of the method for the determination of tungsten and molybdenum in ore samples is presented. The method is applicable to any similar system consisting of two interfering components. 4 figures, 2 tables, 6 refs. (author)

  4. Spectrophotometric readout for an alanine dosimeter for food irradiation applications

    Ebraheem, S.; Beshir, W.B.; Eid, S.; Sobhy, R.; Kovacs, A.

    2003-01-01

    The alanine-electron spin resonance (EPR) readout system is well known as a reference and transfer dosimetry system for the evaluation of high doses in radiation processing. The high cost of an EPR/alanine dosimetry system is a serious handicap for large-scale routine application in irradiation facilities. In this study, the use of a complex produced by dissolving irradiated L-alanine in 1,4-phenyl diammonium dichloride solution was investigated for dosimetry purposes. This complex--having a purple colour--has an increasing absorbance with increasing dose in the range of 1-20 kGy. The applicability of spectrophotometric evaluation was studied by measuring the absorbance intensity of this complex at 360 and 505 nm, respectively. Fluorimetric evaluation was also investigated by measuring the emission of the complex at 435 nm as a function of dose. The present method is easy for routine application. The effect of the dye concentration as well as the suitable amount of irradiated alanine has been studied. With respect to routine application, the stability of the product complex after its formation was also investigated

  5. Spectrophotometric determination of boric acid in boron powder with curcumin

    Grotheer, E.W.

    1979-01-01

    A rapid and accurate method was needed to determine trace amounts of boric acid for quality control and specification testing of elemental boron. The reaction between boric acid and curcumin occurs at a measurable rate only when the curcumin molecule is protonated. Protonation takes place at the carbonyl groups in the presence of a strong acid and occurs completely and rapidly when sulfuric acid is added to a solution of curcumin in acetic acid. Spectrophotometric measurements were made. The extraction of boric acid from boron powder was found to be complete within 2h when either water or the diol solution was used. Whatman No. 40 cr 42 filter paper was used to obtain diol samples free of boron particles. The extraction efficiency of 2-ethyl-1,3-hexanediol was evaluated by adding 1 ml of 500 ppM aqueous boric acid and 1 drop of 10% NaOH to accurately weighed samples of boron powder. The water then was evaporated at room temperature and the samples were extracted with diol solution. The data obtained are included. The extraction efficiency also was evaluated by determining the boric acid content of boron which had been recovered from a previous extraction and boric acid determination. The determination of boric acid using curcumin is unaffected by the presence of other compounds, except for fluoride and nitrate ions. 2 tables

  6. Development of a Draft Core Set of Domains for Measuring Shared Decision Making in Osteoarthritis: An OMERACT Working Group on Shared Decision Making

    Toupin April, Karine; Barton, Jennifer; Fraenkel, Liana; Li, Linda; Grandpierre, Viviane; Guillemin, Francis; Rader, Tamara; Stacey, Dawn; Légaré, France; Jull, Janet; Petkovic, Jennifer; Scholte Voshaar, Marieke; Welch, Vivian; Lyddiatt, Anne; Hofstetter, Cathie; De Wit, Maarten; March, Lyn; Meade, Tanya; Christensen, Robin; Gaujoux-Viala, Cécile; Suarez-Almazor, Maria E.; Boonen, Annelies; Pohl, Christoph; Martin, Richard; Tugwell, Peter

    2015-01-01

    Objective Despite the importance of shared decision making for delivering patient-centred care in rheumatology, there is no consensus on how to measure its process and outcomes. The aim of this OMERACT working group is to determine the core set of domains for measuring shared decision making in intervention studies in adults with osteoarthritis (OA), from the perspective of patients, health professionals and researchers. Methods We followed the OMERACT Filter 2.0 to develop a draft core domain set, which consisted of: (i) forming an OMERACT working group; (ii) conducting a review of domains of shared decision making; and (iii) obtaining the opinions of stakeholders using a modified nominal group process held at a session activity at the OMERACT 2014 meeting. Results 26 stakeholders from Europe, North America and Australia, including 5 patient research partners, participated in the session activity. Participants identified the following domains for measuring shared decision making to be included as part of the Draft Core Set: 1) Identifying the decision; 2) Exchanging Information; 3) Clarifying views; 4) Deliberating; 5) Making the decision; 6) Putting the decision into practice; and 7) Assessing the impact of the decision. Contextual factors were also suggested. Conclusion We propose a Draft Core Set of shared decision making domains for OA intervention research studies. Next steps include a workshop at OMERACT 2016 to reach consensus on these proposed domains in the wider OMERACT group, as well as detail sub-domains and assess instruments to develop a Core Outcome Measurement Set. PMID:25877502

  7. Spectrophotometrical investigation of the NGC 3359 galaxy

    Burenkov, A.N.; Khchikyan, Eh.E.; AN Armyanskoj SSR, Byurakan. Astrofizicheskaya Observatoriya)

    1986-01-01

    Results of detailed spectrophotometrical investigations of NGC 3353, carried out with 6 m telescope of SAO Academy of Sciences of the USSR are presented (dispersion approximately 65 A/mm). Four separate condensations, the brightest of which is Mark 35, are studied. In the spectrum of Mark 35 the emission lines for Hsub(α) to H 12 , HeI lambda lambda 7065, 6678, 5876, 4922, 4472, 3820 and forbidden lines [01]lambda lambdas 6300/64, [02] lambda 3727, [03] lambda lambda 5007, 4959, 4363, [Ne3] lambda 3869, [N2] lambda lambda 6584/48, [S2] lambda lambda 6717/31, [S3] lambda 6310, [Ar3] lambda 7136 are detected. In the second central condensation, called ''nucleus'', emission lines are weaker and beginning with Hsub(β) the absorption components appear which become stronger in the late members of Balmer lines. The forbidden lines in the nucleus are strong: [Ne3], [O3], [O2], [S2][N2]. The relative intensities and equivalent widths of emission lines as well as the chemical composition of Mark 35 and ''nucleus'' are estimated. Both condensations according to their physical properties look like superassociations. It has been concluded that the source of excitation are young stars. NGC 3353 is probably the net of superassociations

  8. Spectrophotometric and Spectrofluorimetric Studies on Azilsartan Medoxomil and Chlorthalidone to be Utilized in Their Determination in Pharmaceuticals

    Walid M. Ebeid

    2014-01-01

    Full Text Available The recently approved angiotensin II receptor blocker, azilsartan medoxomil (AZL, was determined spectrophotometrically and spectrofluorimetrically in its combination with chlorthalidone (CLT in their combined dosage form. The UV-spectrophotometric technique depends on simultaneous measurement of the first derivative spectra for AZL and CLT at 286 and 257 nm, respectively, in methanol. The spectrofluorimetric technique depends on measurement of the fourth derivative of the synchronous spectra intensities of AZL in presence of CLT at 298 nm in methanol. The effects of different solvents on spectrophotometric and spectrofluorimetric responses were studied. For, the spectrofluorimetric study, the effect of pH and micelle-assisted fluorescence enhancement were also studied. Linearity, accuracy, and precision were found to be satisfactory over the concentration ranges of 8-50 μg mL −1 and 2-20 μg mL −1 for AZL and CLT, respectively, in the spectrophotometric method as well as 0.01-0.08 μg mL −1 for AZL in the spectrofluorimetric method. The methods were successfully applied for the determination of the studied drugs in their co-formulated tablets. The developed methods are inexpensive and simple for the quality control and routine analysis of the cited drugs in bulk and in pharmaceuticals.

  9. Determination of niobium in rocks by an isotope dilution spectrophotometric method

    Greenland, L.P.; Campbell, E.Y.

    1970-01-01

    Rocks and minerals are fused with sodium peroxide in the presence of carrierfree 95Nb. The fusion cake is leached with water and the precipitate dissolved in hydrofluoric-sulfuric acid mixture. Niobium is extracted into methyl isobutyl ketone and further purified by ion exchange. The amount of niobium is determined spectrophotometrically with 4-(2-pyridylazo)-resorcinol, and the chemical yield of the separations determined by counting 95Nb. This procedure is faster and less sensitive to interferences than previously proposed methods for determining niobium in rocks.The high purity of the separated niobium makes the method applicable to nearly all matrices. ?? 1970.

  10. Developing model-making and model-breaking skills using direct measurement video-based activities

    Vonk, Matthew; Bohacek, Peter; Militello, Cheryl; Iverson, Ellen

    2017-12-01

    This study focuses on student development of two important laboratory skills in the context of introductory college-level physics. The first skill, which we call model making, is the ability to analyze a phenomenon in a way that produces a quantitative multimodal model. The second skill, which we call model breaking, is the ability to critically evaluate if the behavior of a system is consistent with a given model. This study involved 116 introductory physics students in four different sections, each taught by a different instructor. All of the students within a given class section participated in the same instruction (including labs) with the exception of five activities performed throughout the semester. For those five activities, each class section was split into two groups; one group was scaffolded to focus on model-making skills and the other was scaffolded to focus on model-breaking skills. Both conditions involved direct measurement videos. In some cases, students could vary important experimental parameters within the video like mass, frequency, and tension. Data collected at the end of the semester indicate that students in the model-making treatment group significantly outperformed the other group on the model-making skill despite the fact that both groups shared a common physical lab experience. Likewise, the model-breaking treatment group significantly outperformed the other group on the model-breaking skill. This is important because it shows that direct measurement video-based instruction can help students acquire science-process skills, which are critical for scientists, and which are a key part of current science education approaches such as the Next Generation Science Standards and the Advanced Placement Physics 1 course.

  11. Developing a Tool for Measuring the Decision-Making Competence of Older Adults

    Finucane, Melissa L.; Gullion, Christina M.

    2010-01-01

    The authors evaluated the reliability and validity of a tool for measuring older adults’ decision-making competence (DMC). Two-hundred-five younger adults (25-45 years), 208 young-older adults (65-74 years), and 198 old-older adults (75-97 years) made judgments and decisions related to health, finance, and nutrition. Reliable indices of comprehension, dimension weighting, and cognitive reflection were developed. Unlike previous research, the authors were able to compare old-older with young-older adults’ performance. As hypothesized, old-older adults performed more poorly than young-older adults; both groups of older adults performed more poorly than younger adults. Hierarchical regression analyses showed that a large amount of variance in decision performance across age groups (including mean trends) could be accounted for by social variables, health measures, basic cognitive skills, attitudinal measures, and numeracy. Structural equation modeling revealed significant pathways from three exogenous latent factors (crystallized intelligence, other cognitive abilities, and age) to the endogenous DMC latent factor. Further research is needed to validate the meaning of performance on these tasks for real-life decision making. PMID:20545413

  12. Harnessing monitoring measurements in urban environments for decision making after nuclear accidents

    Kaiser, J.C.; Proehl, G.

    2007-01-01

    This article gives an overview on the conceptual design of the Inhabited Areas Monitoring Module IA MM which will be introduced into European decision support systems for nuclear emergencies. It will improve the use of monitoring data of radioactive contamination in urban environments for decision making. IAMM converts the dated gamma dose rate (GDR) measurements from geo-referenced locations into maps of surface contamination with an enhanced spatial resolution. Depending on the availability of the monitoring data, IAMM relies on two modes of operation. If there are only a few measurements, these are taken to improve the maps from a deposition model using data assimilation. If the number of measurements is sufficient to apply spatial interpolation IAMM will rely entirely on monitoring data. Suitable geo-referenced data points will be interpreted by IAMM with respect to their detector environment using the concept of location factors. The endpoints of IAMM can be used directly for decision making or dose calculations with either simple dose models or the more refined EuRopean Model for INhabited areas (ERMIN). (orig.)

  13. The four principles: Can they be measured and do they predict ethical decision making?

    Page Katie

    2012-05-01

    Full Text Available Abstract Background The four principles of Beauchamp and Childress - autonomy, non-maleficence, beneficence and justice - have been extremely influential in the field of medical ethics, and are fundamental for understanding the current approach to ethical assessment in health care. This study tests whether these principles can be quantitatively measured on an individual level, and then subsequently if they are used in the decision making process when individuals are faced with ethical dilemmas. Methods The Analytic Hierarchy Process was used as a tool for the measurement of the principles. Four scenarios, which involved conflicts between the medical ethical principles, were presented to participants who then made judgments about the ethicality of the action in the scenario, and their intentions to act in the same manner if they were in the situation. Results Individual preferences for these medical ethical principles can be measured using the Analytic Hierarchy Process. This technique provides a useful tool in which to highlight individual medical ethical values. On average, individuals have a significant preference for non-maleficence over the other principles, however, and perhaps counter-intuitively, this preference does not seem to relate to applied ethical judgements in specific ethical dilemmas. Conclusions People state they value these medical ethical principles but they do not actually seem to use them directly in the decision making process. The reasons for this are explained through the lack of a behavioural model to account for the relevant situational factors not captured by the principles. The limitations of the principles in predicting ethical decision making are discussed.

  14. The four principles: Can they be measured and do they predict ethical decision making?

    2012-01-01

    Background The four principles of Beauchamp and Childress - autonomy, non-maleficence, beneficence and justice - have been extremely influential in the field of medical ethics, and are fundamental for understanding the current approach to ethical assessment in health care. This study tests whether these principles can be quantitatively measured on an individual level, and then subsequently if they are used in the decision making process when individuals are faced with ethical dilemmas. Methods The Analytic Hierarchy Process was used as a tool for the measurement of the principles. Four scenarios, which involved conflicts between the medical ethical principles, were presented to participants who then made judgments about the ethicality of the action in the scenario, and their intentions to act in the same manner if they were in the situation. Results Individual preferences for these medical ethical principles can be measured using the Analytic Hierarchy Process. This technique provides a useful tool in which to highlight individual medical ethical values. On average, individuals have a significant preference for non-maleficence over the other principles, however, and perhaps counter-intuitively, this preference does not seem to relate to applied ethical judgements in specific ethical dilemmas. Conclusions People state they value these medical ethical principles but they do not actually seem to use them directly in the decision making process. The reasons for this are explained through the lack of a behavioural model to account for the relevant situational factors not captured by the principles. The limitations of the principles in predicting ethical decision making are discussed. PMID:22606995

  15. Measurement of natural radionuclides in bricks and brick-making clays from Cuddalore district, Tamilnadu, India

    Viruthagirl, G.; Rajamanan, B.; Ravisankar, R.; Thilaivelavan, K.; Chandrasekaran, A.; Meenkshisundram, V.

    2010-01-01

    In India, bricks as building materials are mainly prepared by clay using the deposited sediments of rivers, and the radionuclide contents in bricks and brick-making clays should vary with origin and geological condition. In this paper, the radionuclide contents of these materials from river bank areas of Cuddalore district, Tamilnadu India are measured by gamma ray spectrometer using NaI (Tl) detector, and compared with those of other countries. The radiation hazard indices, which are evaluated by radium-equivalent (Raeq) activity, are lower than that of NEA-OECD. (authors)

  16. Measuring Motivation and Reward-Related Decision Making in the Rodent Operant Touchscreen System.

    Heath, Christopher J; Phillips, Benjamin U; Bussey, Timothy J; Saksida, Lisa M

    2016-01-04

    This unit is designed to facilitate implementation of the fixed and progressive ratio paradigms and the effort-related choice task in the rodent touchscreen apparatus to permit direct measurement of motivation and reward-related decision making in this equipment. These protocols have been optimized for use in the mouse and reliably yield stable performance levels that can be enhanced or suppressed by systemic pharmacological manipulation. Instructions are also provided for the adjustment of task parameters to permit use in mouse models of neurodegenerative disease. These tasks expand the utility of the rodent touchscreen apparatus beyond the currently available battery of cognitive assessment paradigms. Copyright © 2016 John Wiley & Sons, Inc.

  17. THE SPECTROPHOTOMETRIC DETERMINATION OF NITRITES WITH N,N-DIETHYLANILINE

    O. S. Pogrebnyak

    2015-11-01

    Full Text Available A new spectrophotometric method for nitrite determination was proposed. The method is based on the measurement of absorbance of the N,N-diethylaniline nitrosation product at 475 nm in the hydrochloric acid medium. The optimum concentrations and the influence of various conditions on the determination sensitivity have been determined. The detection limit (blank + 3s for nitrite is 0.98 mg∙L–1 where sis the standard deviation of blank estimation. The linearity range of the calibration graph was over 1.0–100 mg∙L–1 of  nitrite (sr≤ 0.029, n = 8. The metrological characteristics of the procedure were checked by means of method of additives on the control samples and natural waters. The relative error did not exceed 0.06 for nitrite determination on the control samples. The effect of foreign ions in nitrite determination of 1,0∙10−3 mol∙L–1 has been studied. The proposed procedure is simple  and suitable for nitrite determination in various objects.

  18. Spectrophotometric Determination of Lamivudine in Pure and Tablet Forms

    A. Biksham Babu

    2012-01-01

    Full Text Available Two visible spectrophotometric methods have been developed for the determination of Lamivudine(LMV in pure and tablet forms. Method-A is based on oxidation of 3-methyl-2-benzathiazolinone hydrazone (MBTH in the presence of iodoso benzene diacetate (IBDA to form electrophilic intermediate which is an active coupling species that reacts with the coupler (LMV by electrophillic attack on the most nucleophilic site on cyclic ring of the coupler. Method-B depends on diazonium salt formation and consequent reaction with resorcinol producing colored product. The absorbances are measured at 590 nm and 540 nm for Method-A and Method-B respectively. Beer's law is obeyed in the concentration range of 10.0-60.0 μg/mL for both the methods. The correlation coefficient which is very close to unity indicates that there is good correlation between concentration and absorbance. LOD, LOQ, confidence levels and relative standard deviation are calculated for the developed methods. The developed methods were successfully applied to tablet forms.

  19. Kinetic spectrophotometric determination of trace amounts of selenium and vanadium

    Safavi, A.; Sedghy, H.R.; Shams, E. [Dept. of Chemistry, Shiraz Univ. (Iran)

    1999-11-01

    A sensitive kinetic spectrophotometric method has been developed for the determination of Se(IV) over the range of 45 to 4000 ng in 10 mL of solution. The method is based on the catalytic effect of Se(IV) on the reduction reaction of bromate by hydrazinium dichloride, with subsequent reaction of Ponceau S with products of the above reaction (chlorine and bromine), causing color changing of Ponceau S. Method development includes optimization of time interval for measurement of slope, pH, reagents concentration, and temperature. The optimized conditions yielded a theoretical detection limit of 33 ng/10 mL of solution of Se(IV). The interfering effects were studied and removed. The method was applied to the determination of selenium in spiked water, Kjeldahl tablet, selenium tablet, and shampoo. Vanadium(V) has an inhibition effect on the catalyzed reaction of bromate and hydrazine by selenium. Using this effect, V(V) can be determined in the range of 70 to 2500 ng in 10 mL of solution. The optimization procedure includes pH and selenium concentration. An extraction method was used for interference removal. The method was applied to the determination of vanadium in petroleum. (orig.)

  20. A far-field-viewing sensor for making analytical measurements in remote locations.

    Michael, K L; Taylor, L C; Walt, D R

    1999-07-15

    We demonstrate a far-field-viewing GRINscope sensor for making analytical measurements in remote locations. The GRINscope was fabricated by permanently affixing a micro-Gradient index (GRIN) lens on the distal face of a 350-micron-diameter optical imaging fiber. The GRINscope can obtain both chemical and visual information. In one application, a thin, pH-sensitive polymer layer was immobilized on the distal end of the GRINscope. The ability of the GRINscope to visually image its far-field surroundings and concurrently detect pH changes in a flowing stream was demonstrated. In a different application, the GRINscope was used to image pH- and O2-sensitive particles on a remote substrate and simultaneously measure their fluorescence intensity in response to pH or pO2 changes.

  1. Extended VIKOR Method for Intuitionistic Fuzzy Multiattribute Decision-Making Based on a New Distance Measure

    Xiao Luo

    2017-01-01

    Full Text Available An intuitionistic fuzzy VIKOR (IF-VIKOR method is proposed based on a new distance measure considering the waver of intuitionistic fuzzy information. The method aggregates all individual decision-makers’ assessment information based on intuitionistic fuzzy weighted averaging operator (IFWA, determines the weights of decision-makers and attributes objectively using intuitionistic fuzzy entropy, calculates the group utility and individual regret by the new distance measure, and then reaches a compromise solution. It can be effectively applied to multiattribute decision-making (MADM problems where the weights of decision-makers and attributes are completely unknown and the attribute values are intuitionistic fuzzy numbers (IFNs. The validity and stability of this method are verified by example analysis and sensitivity analysis, and its superiority is illustrated by the comparison with the existing method.

  2. Psychometrics of shared decision making and communication as patient centered measures for two language groups.

    Alvarez, Kiara; Wang, Ye; Alegria, Margarita; Ault-Brutus, Andrea; Ramanayake, Natasha; Yeh, Yi-Hui; Jeffries, Julia R; Shrout, Patrick E

    2016-09-01

    Shared decision making (SDM) and effective patient-provider communication are key and interrelated elements of patient-centered care that impact health and behavioral health outcomes. Measurement of SDM and communication from the patient's perspective is necessary in order to ensure that health care systems and individual providers are responsive to patient views. However, there is a void of research addressing the psychometric properties of these measures with diverse patients, including non-English speakers, and in the context of behavioral health encounters. This study evaluated the psychometric properties of 2 patient-centered outcome measures, the Shared Decision-Making Questionnaire-9 (SDM-Q) and the Kim Alliance Scale-Communication subscale (KAS-CM), in a sample of 239 English and Spanish-speaking behavioral health patients. One dominant factor was found for each scale and this structure was used to examine whether there was measurement invariance across the 2 language groups. One SDM-Q item was inconsistent with the configural invariance comparison and was removed. The remaining SDM-Q items exhibited strong invariance, meaning that item loadings and item means were similar across the 2 groups. The KAS-CM items had limited variability, with most respondents indicating high communication levels, and the invariance analysis was done on binary versions of the items. These had metric invariance (loadings the same over groups) but several items violated the strong invariance test. In both groups, the SDM-Q had high internal consistency, whereas the KAS-CM was only adequate. These findings help interpret results for individual patients, taking into account cultural and linguistic differences in how patients perceive SDM and patient-provider communication. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  3. Effort-Based Decision Making in Schizophrenia: Evaluation of Paradigms to Measure Motivational Deficits.

    Green, Michael F; Horan, William P

    2015-09-01

    Effort-based decision making requires one to decide how much effort to expend for a certain amount of reward. As the amount of reward goes up most people are willing to exert more effort. This relationship between reward level and effort expenditure can be measured in specialized performance-based tasks that have only recently been applied to schizophrenia. Such tasks provide a way to measure objectively motivational deficits in schizophrenia, which now are only assessed with clinical interviews of negative symptoms. The articles in this theme provide reviews of the relevant animal and human literatures (first 2 articles), and then a psychometric evaluation of 5 effort-based decision making paradigms (last 2 articles). This theme section is intended to stimulate interest in this emerging area among basic scientists developing paradigms for preclinical studies, human experimentalists trying to disentangle factors that contribute to performance on effort-based tasks, and investigators looking for objective endpoints for clinical trials of negative symptoms in schizophrenia. © The Author 2015. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  4. Program to make remote time measurement on the new precise clock system on totem

    Martin, David

    2016-01-01

    For my project at CERN, I worked in the TOTEM team with Michele Quinto and Francesco Cafagna as supervisors. Their team is currently working on an update on TOTEM that includes a module able to measure precisely the time of flight of particles emitted from the collision at CMS. With this additional data, TOTEM will be able to reconstruct precisely the point of the collision in CMS. The main problem posed for this new module is to provide a precise synchronized clock signal to both the TOTEM detectors situated 200 meters after and before CMS. In fact, due to some external parameters, as temperature, the length of the optical fiber guiding the clock signal can vary yielding thus a unwanted phase difference of the clock between the two detectors. The idea is to get rid of the noisy phase difference to make very precise time of flight measurement of the order of the picosecond. This is achieved by continuously measuring the phase difference and correcting the time measurements according to the current phase diffe...

  5. Spectrophotometric Investigations of Macrolide Antibiotics: A Brief Review

    Mrudul R. Keskar

    2015-01-01

    Full Text Available Macrolides, one of the most commonly used class of antibiotics, are a group of drugs produced by Streptomyces species. They belong to the polyketide class of natural products. Their activity is due to the presence of a large macrolide lactone ring with deoxy sugar moieties. They are protein synthesis inhibitors and broad-spectrum antibiotics, active against both gram-positive and gram-negative bacteria. Different analytical techniques have been reported for the determination of macrolides such as chromatographic methods, flow injection methods, spectrofluorometric methods, spectrophotometric methods, and capillary electrophoresis methods. Among these methods, spectrophotometric methods are sensitive and cost effective for the analysis of various antibiotics in pharmaceutical formulations as well as biological samples. This article reviews different spectrophotometric methods for the determination of macrolide antibiotics.

  6. Importance measures in risk-informed decision making: Ranking, optimisation and configuration control

    Vaurio, Jussi K., E-mail: jussi.vaurio@pp1.inet.fi [Prometh Solutions, Hiihtaejaenkuja 3K, 06100 Porvoo (Finland)

    2011-11-15

    This paper describes roles, extensions and applications of importance measures of components and configurations for making risk-informed decisions relevant to system operations, maintenance and safety. Basic importance measures and their relationships are described for independent and mutually exclusive events and for groups of events associated with common cause failures. The roles of importances are described mainly in two groups of activities: (a) ranking safety significance of systems, structures, components and human actions for preventive safety assurance activities, and (b) making decisions about permissible permanent and temporary configurations and allowed configuration times for regulation, technical specifications and for on-line risk monitoring. Criticality importance and sums of criticalities turn out to be appropriate measures for ranking and optimization. Several advantages are pointed out and consistent ranking of pipe segments for in-service inspection is provided as an example. Risk increase factor and its generalization risk gain are most appropriately used to assess corrective priorities and acceptability of a situation when components are already failed or when planning to take one or more components out of service for maintenance. Precise definitions are introduced for multi-failure configurations and it is shown how they can be assessed under uncertainties, in particular when common cause failures or success states may be involved. A general weighted average method is compared to other candidate methods in benchmark cases. It is the preferable method for prediction when a momentary configuration is known or only partially known. Potential applications and optimization of allowed outage times are described. The results show how to generalize and apply various importance measures to ranking and optimization and how to manage configurations in uncertain multi-failure situations. - Highlights: > Rigorous methods developed for using importances

  7. Importance measures in risk-informed decision making: Ranking, optimisation and configuration control

    Vaurio, Jussi K.

    2011-01-01

    This paper describes roles, extensions and applications of importance measures of components and configurations for making risk-informed decisions relevant to system operations, maintenance and safety. Basic importance measures and their relationships are described for independent and mutually exclusive events and for groups of events associated with common cause failures. The roles of importances are described mainly in two groups of activities: (a) ranking safety significance of systems, structures, components and human actions for preventive safety assurance activities, and (b) making decisions about permissible permanent and temporary configurations and allowed configuration times for regulation, technical specifications and for on-line risk monitoring. Criticality importance and sums of criticalities turn out to be appropriate measures for ranking and optimization. Several advantages are pointed out and consistent ranking of pipe segments for in-service inspection is provided as an example. Risk increase factor and its generalization risk gain are most appropriately used to assess corrective priorities and acceptability of a situation when components are already failed or when planning to take one or more components out of service for maintenance. Precise definitions are introduced for multi-failure configurations and it is shown how they can be assessed under uncertainties, in particular when common cause failures or success states may be involved. A general weighted average method is compared to other candidate methods in benchmark cases. It is the preferable method for prediction when a momentary configuration is known or only partially known. Potential applications and optimization of allowed outage times are described. The results show how to generalize and apply various importance measures to ranking and optimization and how to manage configurations in uncertain multi-failure situations. - Highlights: → Rigorous methods developed for using importances

  8. Determination of loratadine in pharmaceuticals by a spectrophotometric method

    Pavalache Georgeta

    2015-06-01

    Full Text Available The spectrophotometric method for determination of loratadine using tetraiodomercurate has been applied in various pharmaceutical formulations. The results confirmed that recovery value is optimum and the method is valid, thus it can be used in quality control and evaluation of loratadine tablets, oral formulations of mixed composition, oral solutions, etc. The method is easy and simple to apply, does not require complicated equipment and spectrophotometric reading time is reduced, which allows a large number of analyzes in a relatively short time.

  9. The making of pressure measurement device on heating-02 based realtime

    Giarno; Kussigit Santosa; Agus Nur Rachman; G B Heru K

    2013-01-01

    In order to modify the installation strand BETA Test Section Test integrated with heating-02 into a closed loop, it would require an additional system that can measure pressure changes in the closed-loop system. By making the measurement device to test the system pressure at the heating-expected 02 researchers can monitor the pressure changes that occur in the system. The pressure gauge device fabrication using manufacturing simulation methodology, the preparation of the hardware and software and test functions. Manufacturing simulation using measuring devices HIOKI DC current source Signal Source, preparation of pressure measurement devices require hardware such as pressure transducers, NI cRIO-9074, NI 9203 analog module, Computer and software LabVIEW 2011 as programming. In the test process function method is used to provide flow simulation module that is connected to the 9203 NI NI cRIO-9074. Current provision tailored to the specifics pressure transducer is 4 mA s/d 20 mA. Based on the test results obtained function value of the lowest current is 4.00 mA = 0.001 bar, and the highest current value of 20.00 mA = 4995 bar. From the results of calculations using the linear equations obtained correlation coefficient (R 2 ) of 0.999, so it is evident that the pressure changes in LabVIEW is affected by changes in flow. The results obtained from this activity is a device that can measure the pressure in the heating-02 test. (author)

  10. Multi-wavelength spectrophotometric analysis for detection of xanthochromia in cerebrospinal fluid and accuracy for the diagnosis of subarachnoid hemorrhage.

    Smith, Andrew; Wu, Alan H B; Lynch, Kara L; Ko, Nerissa; Grenache, David G

    2013-09-23

    Cerebrospinal fluid (CSF) was examined for bilirubin, an important indicator for diagnosis of subarachnoid hemorrhage (SAH). A multi-wavelength (340, 415, and 460 nm) spectrophotometric assay was developed for the quantitative measurement of bilirubin in CSF, enabling the mathematical correction for absorbance of hemoglobin and proteins. Bilirubin and hemoglobin results were correlated to HPLC and a standard colorimetric assay, respectively. A subset of samples was sent for an absorbance reading at 450 nm following baseline correction. The multi-wavelength bilirubin assay was validated on 70 patients with confirmed SAH and 70 patients with neurologic symptoms who ruled out for SAH. The multi-wavelength spectrophometric assay demonstrated no interferences due to proteins (albumin) up to 30 g/l or oxyhemoglobin up to 260 mg/l. The assay limit of detection was 0.2 mg/l, linear to 20 mg/l, and CVs ranged from 1 to 6% at bilirubin concentrations of 0.84 and 2.1mg/l. The spectrophotometric assay correlated to HPLC and the colorimetric assay for bilirubin and hemoglobin, respectively. Results also correlated to the absorbance method (with removal of samples with high hemoglobin and proteins). The area under the ROC curve for diagnosis of SAH was 0.971 and 0.954 for the HPLC and spectrophotometric assay, respectively. At a cutoff of 0.2mg/l, the clinical specificity was 100% for both assays, and the clinical sensitivity was 94.3% and 88.6% for SAH for the HPLC and spectrophotometric asays, respectively. The multi-wavelength spectrophotometric assay is an objective alternative to visual inspection, HPLC, and absorbance for CSF bilirubin. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Different Spectrophotometric and Chromatographic Methods for Determination of Mepivacaine and Its Toxic Impurity.

    Abdelwahab, Nada S; Fared, Nehal F; Elagawany, Mohamed; Abdelmomen, Esraa H

    2017-09-01

    Stability-indicating spectrophotometric, TLC-densitometric, and ultra-performance LC (UPLC) methods were developed for the determination of mepivacaine HCl (MEP) in the presence of its toxic impurity, 2,6-dimethylanaline (DMA). Different spectrophotometric methods were developed for the determination of MEP and DMA. In a dual-wavelength method combined with direct spectrophotometric measurement, the absorbance difference between 221.4 and 240 nm was used for MEP measurements, whereas the absorbance at 283 nm was used for measuring DMA in the binary mixture. In the second-derivative method, amplitudes at 272.2 and 232.6 nm were recorded and used for the determination of MEP and DMA, respectively. The developed TLC-densitometric method depended on chromatographic separation using silica gel 60 F254 TLC plates as a stationary phase and methanol-water-acetic acid (9 + 1 + 0.1, v/v/v) as a developing system, with UV scanning at 230 nm. The developed UPLC method depended on separation using a C18 column (250 × 4.6 mm id, 5 μm particle size) as a stationary phase and acetonitrile-water (40 + 60, v/v; pH 4 with phosphoric acid) as a mobile phase at a flow rate of 0.4 mL/min, with UV detection at 215 nm. The chromatographic run time was approximately 1 min. The proposed methods were validated with respect to International Conference on Harmonization guidelines regarding precision, accuracy, ruggedness, robustness, and specificity.

  12. Spectrophotometric Methods for Simultaneous Determination of Oxytetracycline HCl and Flunixin Meglumine in Their Veterinary Pharmaceutical Formulation

    Hanan A. Merey

    2017-01-01

    Full Text Available Four precise, accurate, selective, and sensitive UV-spectrophotometric methods were developed and validated for the simultaneous determination of a binary mixture of Oxytetracycline HCl (OXY and Flunixin Meglumine (FLU. The first method, dual wavelength (DW, depends on measuring the difference in absorbance (ΔA 273.4–327 nm for the determination of OXY where FLU is zero while FLU is determined at ΔA 251.7–275.7 nm. The second method, first-derivative spectrophotometric method (1D, depends on measuring the peak amplitude of the first derivative selectively at 377 and 266.7 nm for the determination of OXY and FLU, respectively. The third method, ratio difference method, depends on the difference in amplitudes of the ratio spectra at ΔP 286.5–324.8 nm and ΔP 249.6–286.3 nm for the determination of OXY and FLU, respectively. The fourth method, first derivative of ratio spectra method (1DD, depends on measuring the amplitude peak to peak of the first derivative of ratio spectra at 296.7 to 369 nm and 259.1 to 304.7 nm for the determination of OXY and FLU, respectively. Different factors affecting the applied spectrophotometric methods were studied. The proposed methods were validated according to ICH guidelines. Satisfactory results were obtained for determination of both drugs in laboratory prepared mixture and pharmaceutical dosage form. The developed methods are compared favourably with the official ones.

  13. Spectrophotometric studies of marine surfactants in the southern Baltic Sea

    Violetta Drozdowska

    2015-04-01

    Full Text Available It is well known that surfactants in the southern Baltic Sea constitute the organic matter from riverine waters discharges as well as the secondary degradation products of marine phytoplankton excretion. They reach the surface microlayer by the upwellings and turbulent motions of water and in the membranes of the vesicles as well as from the atmosphere. To assess concentration and spatial distribution of marine surfactants in the southern Baltic Sea, the steady-state spectrophotometric and spectrofluorometric measurements of water samples taken from a surface film and a depth of 0.5 m were carried out. Water samples were collected during windless days of the cruise of r/v ‘Oceania’ in November 2012, from the open and the coastal waters having regard to the vicinity of the Vistula and Łeba mouths. In the present paper, fractions of dissolved organic matter having chromophores (CDOM or fluorophores (FDOM are recognized through their specific spectroscopic behavior, i.e., steady-state absorption, fluorescence excitation and fluorescence spectra. The steady-state spectroscopic measurements revealed the CDOM and FDOM molecules characteristic to both the land and marine origin. Moreover, the concentration and spatial distribution of marine surfactants significantly depend on the distance from the river mouth. Finally, higher values of absorbance and fluorescence intensity observed in a surface film in comparison to these values in a depth of 0.5 m clearly suggest the higher concentration of organic matter in a marine film. On the other hand, our results revealed that a surface microlayer is composed of the same CDOM and FDOM as bulk water.

  14. Highly sensitive spectrophotometric kinetic determination of vanadium by catalysis of the gallic acid-bromate reaction

    Fukasawa, Tsutomu; Kawakubo, Susumu; Yamanouchi, Tatsuo

    1985-01-01

    Conditions are described for improving the speed and sensitivity of this catalytic determination of vanadium. The reaction of 0.018 M gallic acid with 0.96 M sodium bromate at pH 3.8 and double-beam spectrophotometric measurement at 380 nm are recommended. The highest practical sensitivity at 22-30 0 C was ca. 40 pg for an absorbance change of 0.0005, 50 times better than previously. The detection limit was ca. 0.5 ng of vanadium. Reaction at 50 0 C gave even better sensitivity. (Auth.)

  15. Quantization of buspirone hydrochloride in pure and pharmaceutical formulation by spectrophotometric method

    Kazi, A.A.; Mumtaz, A.; Sabri, M.U.

    2008-01-01

    A simple and sensitive method is described for the determination of bus pirone hydrochloride in bulk drug and in formulations employing spectrophotometric technique. The method is based on the interaction orbuspirone hydrochloride with ammonium molybdate in acidic media and the absorbance is measured at 700 nm. Beer's Law is obeyed in the range of 5 macro g to 350 micro g/ml and RSD is 0.96% for buspirone hydrochloride. Analytical data for the determination of pure compound is presented along with the application of the proposed method for the analysis of pharmaceutical formulation. (author)

  16. Derivative spectrophotometric method for simultaneous determination of clindamycin phosphate and tretinoin in pharmaceutical dosage forms.

    Barazandeh Tehrani, Maliheh; Namadchian, Melika; Fadaye Vatan, Sedigheh; Souri, Effat

    2013-04-10

    A derivative spectrophotometric method was proposed for the simultaneous determination of clindamycin and tretinoin in pharmaceutical dosage forms. The measurement was achieved using the first and second derivative signals of clindamycin at (1D) 251 nm and (2D) 239 nm and tretinoin at (1D) 364 nm and (2D) 387 nm.The proposed method showed excellent linearity at both first and second derivative order in the range of 60-1200 and 1.25-25 μg/ml for clindamycin phosphate and tretinoin respectively. The within-day and between-day precision and accuracy was in acceptable range (CVpharmaceutical dosage form.

  17. Multi-Attribute Decision Making Based on Several Trigonometric Hamming Similarity Measures under Interval Rough Neutrosophic Environment

    Surapati Pramanik

    2018-03-01

    Full Text Available In this paper, the sine, cosine and cotangent similarity measures of interval rough neutrosophic sets is proposed. Some properties of the proposed measures are discussed. We have proposed multi attribute decision making approaches based on proposed similarity measures. To demonstrate the applicability, a numerical example is solved.

  18. Determination of cyanide by a highly sensitive indirect spectrophotometric method.

    Blanco, M; Maspoch, S

    1984-01-01

    Complexation of Pd(2+) with cyanide inhibits the extraction of the palladium complex of 5-phenylazo-8-aminoquinoline. This effect is used for the indirect spectrophotometric determination of cyanide at the mug level. Cyanide in industrial waste water and in sea-water is determined after distillation as HCN from the sample and collection in sodium hydroxide solution.

  19. Spectrophotometric determination of pizotefin maleate in pure form ...

    Two simple, quick and sensitive methods were described for the spectrophotometric determination of pizotefin maleate (PZT) either in pure form or pharmaceutical form (tablets). The methods were based on the reaction of pizotefin maleate as 'n' electron donor with chloranilic acid (p-CLA) and 7,7,8 ...

  20. NEW SPECTROPHOTOMETRIC METHOD WITH KMnO 4 FOR ...

    The new method, an instrument-based and simple experimental procedure involves the reaction of the hypochlorite with arsenious oxide (As2O3) (pH 6.5) followed by the coupled reaction of residual As2O3 with permanganate at acidic pH. A titration procedure is described and spectrophotometric method is designed using ...

  1. Spectrophotometric and theoretical studies on the determination of ...

    Purpose: To develop a simple and cost effective spectrophotometric method for the ... species exhibited absorption maxima at 410 and 479 nm for the two systems in ... etilefrine in plasma and urine in pharmacokinetic ... In this work, the interactions of ET with BCG and ... prepared where the total volume of investigated.

  2. New simple spectrophotometric assay of total carotenes in margarines

    Luterotti, S.; Bicanic, D.D.; Pozgaj, R.

    2006-01-01

    Direct and reliable spectrophotometric method for assaying total carotenes (TC) in margarines with the minimum of sample manipulation is proposed. For the first time saponification step used in determination of carotenes in margarines was omitted leading to a substantial cost saving and reduction of

  3. A Spectrophotometric Method for the Determination of Ramipril in ...

    A Spectrophotometric Method for the Determination of Ramipril in Solid Dosage Forms. ... Tropical Journal of Pharmaceutical Research ... Methods: UV spectrophotometry was used to develop and validate a simple method for the assay of ramipril in solid dosage form at λmax of 210 nm, as per International Conference on ...

  4. Eliminating amino acid interference during spectrophotometric NH4+ analysis

    Ros, G.H.; Leeuwen, van A.G.; Temminghoff, E.J.M.

    2011-01-01

    Amino acids can interfere with NH4+ in spectrophotometric NH4+ determination hampering accurate quantification of the fate of NH4+ and dissolved organic N in soils. Serious interference has been reported for soils rich in organic matter, and for soils that have been fumigated, oven-dried or

  5. Spectrophotometric Determination of Cilostazol in Tablet Dosage Form

    Purpose: To develop simple, rapid and selective spectrophotometric methods for the determination of cilostazol in tablet dosage form. Methods: Cilostazol was dissolved in 50 % methanol and its absorbance was scanned by ultraviolet (UV) spectrophotometry. Both linear regression equation and standard absorptivity were ...

  6. Making the Handoff from Earthquake Hazard Assessments to Effective Mitigation Measures (Invited)

    Applegate, D.

    2010-12-01

    This year has witnessed a barrage of large earthquakes worldwide with the resulting damages ranging from inconsequential to truly catastrophic. We cannot predict when earthquakes will strike, but we can build communities that are resilient to strong shaking as well as to secondary hazards such as landslides and liquefaction. The contrasting impacts of the magnitude-7 earthquake that struck Haiti in January and the magnitude-8.8 event that struck Chile in April underscore the difference that mitigation and preparedness can make. In both cases, millions of people were exposed to severe shaking, but deaths in Chile were measured in the hundreds rather than the hundreds of thousands that perished in Haiti. Numerous factors contributed to these disparate outcomes, but the most significant is the presence of strong building codes in Chile and their total absence in Haiti. The financial cost of the Chilean earthquake still represents an unacceptably high percentage of that nation’s gross domestic product, a reminder that life safety is the paramount, but not the only, goal of disaster risk reduction measures. For building codes to be effective, both in terms of lives saved and economic cost, they need to reflect the hazard as accurately as possible. As one of four federal agencies that make up the congressionally mandated National Earthquake Hazards Reduction Program (NEHRP), the U.S. Geological Survey (USGS) develops national seismic hazard maps that form the basis for seismic provisions in model building codes through the Federal Emergency Management Agency and private-sector practitioners. This cooperation is central to NEHRP, which both fosters earthquake research and establishes pathways to translate research results into implementation measures. That translation depends on the ability of hazard-focused scientists to interact and develop mutual trust with risk-focused engineers and planners. Strengthening that interaction is an opportunity for the next generation

  7. Spectrophotometric Analysis of Phosphoric Acid Leakage in High-Temperature Phosphoric Acid-Doped Polybenzimidazole Membrane Fuel Cell Application

    Seungyoon Han

    2016-01-01

    Full Text Available High-temperature proton exchange membrane fuel cells (HT-PEMFCs utilize a phosphoric acid- (PA- doped polybenzimidazole (PBI membrane as a polymer electrolyte. The PA concentration in the membrane can affect fuel cell performance, as a significant amount of PA can leak from the membrane electrode assembly (MEA by dissolution in discharged water, which is a byproduct of cell operation. Spectrophotometric analysis of PA leakage in PA-doped polybenzimidazole membrane fuel cells is described here. This spectrophotometric analysis is based on measurement of absorption of an ion pair formed by phosphomolybdic anions and the cationoid color reagent. Different color reagents were tested based on PA detection sensitivity, stability of the formed color, and accuracy with respect to the amount of PA measured. This method allows for nondestructive analysis and monitoring of PA leakage during HT-PEMFCs operation.

  8. Spectrophotometric and spectrofluorimetric determination of some drugs containing secondary amino group in bulk drug and dosage forms via derivatization with 7-Chloro-4-Nitrobenzofurazon

    Armaan Önal

    2011-01-01

    Full Text Available Sensitive and selective spectrophotometric and spectrofluorimetric methods have been developed for determination of some drugs such as Pramipexole, Nebivolol, Carvedilol, and Eletriptan, which commonly contain secondary amino group. The subject methods were developed via derivatization of the secondary amino groups with 7-Chloro-4-Nitrobenzofurazon in borate buffer where a yellow colored reaction product was obtained and measured spectrophotometrically or spectrofluorimetrically. Concentration ranges were found as 2.0 to 250 μg mL-1 and 0.1 to 3.0 μg mL-1, for spectrophotometric and spectrofluorimetric study, respectively. The described methods can be easily applied by the quality control laboratories in routine analyses of these drugs in pharmaceutical preparations.

  9. Reliable electricity. The effects of system integration and cooperative measures to make it work

    Hagspiel, Simeon; Koeln Univ.

    2017-01-01

    We investigate the effects of system integration for reliability of supply in regional electricity systems along with cooperative measures to support it. Specifically, we set up a model to contrast the benefits from integration through statistical balancing (i.e., a positive externality) with the risk of cascading outages (a negative externality). The model is calibrated with a comprehensive dataset comprising 28 European countries on a high spatial and temporal resolution. We find that positive externalities from system integration prevail, and that cooperation is key to meet reliability targets efficiently. To enable efficient solutions in a non-marketed environment, we formulate the problem as a cooperative game and study different rules to allocate the positive and negative effects to individual countries. Strikingly, we find that without a mechanism, the integrated solution is unstable. In contrast, proper transfer payments can be found to make all countries better off in full integration, and the Nucleolus is identified as a particularly promising candidate. The rule could be used as a basis for compensation payments to support the successful integration and cooperation of electricity systems.

  10. Reliable electricity. The effects of system integration and cooperative measures to make it work

    Hagspiel, Simeon [Koeln Univ. (Germany). Energiewirtschaftliches Inst.; Koeln Univ. (Germany). Dept. of Economics

    2017-12-15

    We investigate the effects of system integration for reliability of supply in regional electricity systems along with cooperative measures to support it. Specifically, we set up a model to contrast the benefits from integration through statistical balancing (i.e., a positive externality) with the risk of cascading outages (a negative externality). The model is calibrated with a comprehensive dataset comprising 28 European countries on a high spatial and temporal resolution. We find that positive externalities from system integration prevail, and that cooperation is key to meet reliability targets efficiently. To enable efficient solutions in a non-marketed environment, we formulate the problem as a cooperative game and study different rules to allocate the positive and negative effects to individual countries. Strikingly, we find that without a mechanism, the integrated solution is unstable. In contrast, proper transfer payments can be found to make all countries better off in full integration, and the Nucleolus is identified as a particularly promising candidate. The rule could be used as a basis for compensation payments to support the successful integration and cooperation of electricity systems.

  11. A new optical sensor for spectrophotometric determination of uranium (VI) and thorium (IV) in acidic medium

    Elhefnawy, O.A. [Nuclear and Radiological Regulatory Authority (NRRA), Cairo (Egypt). Nuclear Safeguards and Physical Protection Dept.

    2017-07-01

    A spectrophotometric method was developed for U(VI) and Th(IV) determination in acidic medium by using proposed optical sensor. This sensor is base on the complexation reaction of the ionophore midodrine hydrochloride (L) with U(VI)/Th(IV) in plasticized (o-NPOE) high molecular weight (PVC). Several parameters such as effect of acidic medium, response time and sensor compositions were studied. The determination of the complexes stoichiometry was also studied using Job's method. The complexes stoichiometry were measured at the absorbance spectra 302 nm and the results were found to be 1:1 for both complexes U(VI)-L and Th(IV)-L. The complexation reaction was extremely rapid at room temperature; it takes 5, 10 min to complete the complexation reaction in U(VI) and Th(IV), respectively. Under the optimum conditions the calibration curves of U(VI)/Th(IV) determination, have good linearity at different acidic medium nitric, sulfuric, and phosphoric acids with low detection and quantification limits. The accuracy and precision studies proved that the proposed optical sensor is valid and qualified for U(VI)/Th(IV) spectrophotometric determination in different acidic medium. The selectivity of the proposed optical sensor was studied. The proposed optical sensor was applied successfully for U(VI)/Th(IV) determination in research and development (R and D) nuclear waste samples with satisfactory results. A comparative study of the proposed optical sensor with other previous spectrophotometric sensors for U(VI)/Th(IV) determination, proved the high efficiency of the proposed optical sensor, that it presents wide linear range and low detection limit. The proposed optical sensor could be applied for a quantitative determination of U(VI)/Th(IV) in acidic waste samples.

  12. A new optical sensor for spectrophotometric determination of uranium (VI) and thorium (IV) in acidic medium

    Elhefnawy, O.A.

    2017-01-01

    A spectrophotometric method was developed for U(VI) and Th(IV) determination in acidic medium by using proposed optical sensor. This sensor is base on the complexation reaction of the ionophore midodrine hydrochloride (L) with U(VI)/Th(IV) in plasticized (o-NPOE) high molecular weight (PVC). Several parameters such as effect of acidic medium, response time and sensor compositions were studied. The determination of the complexes stoichiometry was also studied using Job's method. The complexes stoichiometry were measured at the absorbance spectra 302 nm and the results were found to be 1:1 for both complexes U(VI)-L and Th(IV)-L. The complexation reaction was extremely rapid at room temperature; it takes 5, 10 min to complete the complexation reaction in U(VI) and Th(IV), respectively. Under the optimum conditions the calibration curves of U(VI)/Th(IV) determination, have good linearity at different acidic medium nitric, sulfuric, and phosphoric acids with low detection and quantification limits. The accuracy and precision studies proved that the proposed optical sensor is valid and qualified for U(VI)/Th(IV) spectrophotometric determination in different acidic medium. The selectivity of the proposed optical sensor was studied. The proposed optical sensor was applied successfully for U(VI)/Th(IV) determination in research and development (R and D) nuclear waste samples with satisfactory results. A comparative study of the proposed optical sensor with other previous spectrophotometric sensors for U(VI)/Th(IV) determination, proved the high efficiency of the proposed optical sensor, that it presents wide linear range and low detection limit. The proposed optical sensor could be applied for a quantitative determination of U(VI)/Th(IV) in acidic waste samples.

  13. Validated spectrophotometric methods for determination of Alendronate sodium in tablets through nucleophilic aromatic substitution reactions

    Walash Mohamed I

    2012-04-01

    Full Text Available Abstract Background Alendronate (ALD is a member of the bisphosphonate family which is used for the treatment of osteoporosis, bone metastasis, Paget's disease, hypocalcaemia associated with malignancy and other conditions that feature bone fragility. ALD is a non-chromophoric compound so its determination by conventional spectrophotometric methods is not possible. So two derivatization reactions were proposed for determination of ALD through the reaction with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl and 2,4-dinitrofluorobenzene (DNFB as chromogenic derivatizing reagents. Results Three simple and sensitive spectrophotometric methods are described for the determination of ALD. Method I is based on the reaction of ALD with NBD-Cl. Method II involved heat-catalyzed derivatization of ALD with DNFB, while, Method III is based on micellar-catalyzed reaction of the studied drug with DNFB at room temperature. The reactions products were measured at 472, 378 and 374 nm, for methods I, II and III, respectively. Beer's law was obeyed over the concentration ranges of 1.0-20.0, 4.0-40.0 and 1.5-30.0 μg/mL with lower limits of detection of 0.09, 1.06 and 0.06 μg/mL for Methods I, II and III, respectively. The proposed methods were applied for quantitation of the studied drug in its pure form with mean percentage recoveries of 100.47 ± 1.12, 100.17 ± 1.21 and 99.23 ± 1.26 for Methods I, II and III, respectively. Moreover the proposed methods were successfully applied for determination of ALD in different tablets. Proposals of the reactions pathways have been postulated. Conclusion The proposed spectrophotometric methods provided sensitive, specific and inexpensive analytical procedures for determination of the non-chromophoric drug alendronate either per se or in its tablet dosage forms without interference from common excipients. Graphical abstract

  14. Simultaneous determination of the brand new two-drug combination for the treatment of hepatitis C: Sofosbuvir/ledipasvir using smart spectrophotometric methods manipulating ratio spectra

    Eissa, Maya S.

    2017-08-01

    In this work, various sensitive and selective spectrophotometric methods were first introduced for the simultaneous determination of sofosbuvir and ledipasvir in their binary mixture without preliminary separation. Ledipasvir was determined simply by zero-order spectrophotometric method at its λmax = 333.0 nm in a linear range of 2.5-30.0 μg/ml without any interference of sofosbuvir even in low or high concentrations and with mean percentage recovery of 100.05 ± 0.632. Sofosbuvir can be quantitatively estimated by one of the following smart spectrophotometric methods based on ratio spectra developed for the resolution of the overlapped spectra of their binary mixture; ratio difference spectrophotometric method (RD) by computing the difference between the amplitudes of sofosbuvir ratio spectra at 228 nm and 270 nm, first derivative (DD1) of ratio spectra by measuring the sum of amplitude of trough and peak at 265 nm and 277 nm, respectively, ratio subtraction (RS) spectrophotometric method in which sofosbuvir can be successfully determined at its λmax = 261.0 nm and mean centering (MC) of ratio spectra by measuring the mean centering values at 270 nm. All of the above mentioned spectrophotometric methods can estimate sofosbuvir in a linear range of 7.5-90.0 μg/ml with mean percentage recoveries of 100.57 ± 0.810, 99.92 ± 0.759, 99.51 ± 0.475 and 100.75 ± 0.672, respectively. These methods were successfully applied to the analysis of their combined dosage form and bulk powder. The adopted methods were also validated as per ICH guidelines and statistically compared to an in-house HPLC method.

  15. Clonidine improved laboratory-measured decision-making performance in abstinent heroin addicts.

    Xiao-Li Zhang

    Full Text Available BACKGROUND: Impulsivity refers to a wide spectrum of actions characterized by quick and nonplanned reactions to external and internal stimuli, without taking into account the possible negative consequences for the individual or others, and decision-making is one of the biologically dissociated impulsive behaviors. Changes in impulsivity may be associated with norepinephrine. Various populations of drug addicts all performed impulsive decision making, which is a key risk factor in drug dependence and relapse. The present study investigated the effects of clonidine, which decreased norepinephrine release through presynaptic alpha-2 receptor activation, on the impaired decision-making performance in abstinent heroin addicts. METHODOLOGY/PRINCIPAL FINDINGS: Decision-making performance was assessed using the original version of Iowa Gambling Task (IGT. Both heroin addicts and normal controls were randomly assigned to three groups receiving clonidine, 0, 75 µg or 150 µg orally under double blind conditions. Psychiatric symptoms, including anxiety, depression and impulsivity, were rated on standardized scales. Heroin addicts reported higher scores on the Barratt Impulsiveness Scale and exhibited impaired decision-making on the IGT. A single high-dose of clonidine improved the decision-making performance in heroin addicts. CONCLUSIONS/SIGNIFICANCE: Our results suggest clonidine may have a potential therapeutic role in heroin addicts by improving the impaired impulsive decision-making. The current findings have important implications for behavioral and pharmacological interventions targeting decision-making in heroin addiction.

  16. On intervention levels for nuclear or radiological emergency and decision-making on protective measures

    Wang Hengde; Nakashima, Y.

    1999-01-01

    The intervention principles and intervention levels newly recommended by ICRP and IAEA are introduced, the necessarily of determining site specific intervention levels is discussed, the method of estimating intervention levels with human capital approach by an example of Japan case is described, and finally decision-making issues are discussed and a decision-making chain is given

  17. Automated spectrophotometric bicarbonate analysis in duodenal juice compared to the back titration method.

    Erchinger, Friedemann; Engjom, Trond; Gudbrandsen, Oddrun Anita; Tjora, Erling; Gilja, Odd H; Dimcevski, Georg

    2016-01-01

    We have recently evaluated a short endoscopic secretin test for exocrine pancreatic function. Bicarbonate concentration in duodenal juice is an important parameter in this test. Measurement of bicarbonate by back titration as the gold standard method is time consuming, expensive and technically difficult, thus a simplified method is warranted. We aimed to evaluate an automated spectrophotometric method in samples spanning the effective range of bicarbonate concentrations in duodenal juice. We also evaluated if freezing of samples before analyses would affect its results. Patients routinely examined with short endoscopic secretin test suspected to have decreased pancreatic function of various reasons were included. Bicarbonate in duodenal juice was quantified by back titration and automatic spectrophotometry. Both fresh and thawed samples were analysed spectrophotometrically. 177 samples from 71 patients were analysed. Correlation coefficient of all measurements was r = 0.98 (p titration gold standard. This is a major simplification of direct pancreas function testing, and allows a wider distribution of bicarbonate testing in duodenal juice. Extreme values for Bicarbonate concentration achieved by the autoanalyser method have to be interpreted with caution. Copyright © 2016 IAP and EPC. Published by Elsevier India Pvt Ltd. All rights reserved.

  18. Comparison of gravimetric and spectrophotometric methods for the determination of O/U ratios in uranium oxides

    Esteban, Adolfo; Eppis, Maria Rosa

    2004-01-01

    One important parameter to specify in nuclear fuels is the oxygen-metal ratio; many tests were described in literature to determine it. Possibly, gravimetric methods are the most used and usually a good precision was obtained analysing sintered materials. However, the humidity sorbed in the samples and impurities affect these methods, especially in powders. On the other hand, the spectrophotometric methods determine oxygen-uranium ratio by measuring the absorbances of different ionic species in phosphoric acid. This technique is simply and is not affected by humidity and impurities. Owing to discrepancy in the results between both methods, it was carried out in our laboratory, a study on various gravimetric and spectrophotometric methods. Several assays and analysis were performed comparing test procedures, trying to obtain better precision and accuracy. This work presents the results obtained and the recommend procedure to use with sintered and unsintered materials

  19. Determination of dissociation constants for coordination compounds of Cr(III) and Co(III) using potentiometric and spectrophotometric methods

    Chylewska, A.; Jacewicz, D.; Zarzeczanska, D. [Department of Chemistry, University of Gdansk, Sobieskiego 18/19, 80-952 Gdansk (Poland); Chmurzynski, L. [Department of Chemistry, University of Gdansk, Sobieskiego 18/19, 80-952 Gdansk (Poland)], E-mail: lech@chem.univ.gda.pl

    2008-08-15

    The acid-base properties of analogous complex ions of chromium(III) and cobalt(III) in aqueous solution have been studied. The equilibrium constants for all metal complexes were determined by using potentiometric and spectrophotometric titration methods. First, dissociation constants for the studied complexes of Cr(III) and Co(III) were determined by means of the potentiometric titration method and using the STOICHIO computer programme. Then, pH-spectrophotometric titrations were performed and the OriginPro 7.5 computer programme was used to calculate the same constants. The measurements using both methods were carried out under the same conditions of temperature, T = 298.15 K, and over the same pH range 2.00-10.00, respectively. It turned out that the two methods used enabled us to obtain acidity constants in very good agreement.

  20. Determination of dissociation constants for coordination compounds of Cr(III) and Co(III) using potentiometric and spectrophotometric methods

    Chylewska, A.; Jacewicz, D.; Zarzeczanska, D.; Chmurzynski, L.

    2008-01-01

    The acid-base properties of analogous complex ions of chromium(III) and cobalt(III) in aqueous solution have been studied. The equilibrium constants for all metal complexes were determined by using potentiometric and spectrophotometric titration methods. First, dissociation constants for the studied complexes of Cr(III) and Co(III) were determined by means of the potentiometric titration method and using the STOICHIO computer programme. Then, pH-spectrophotometric titrations were performed and the OriginPro 7.5 computer programme was used to calculate the same constants. The measurements using both methods were carried out under the same conditions of temperature, T = 298.15 K, and over the same pH range 2.00-10.00, respectively. It turned out that the two methods used enabled us to obtain acidity constants in very good agreement

  1. Individual v. community-level measures of women's decision-making ...

    These questions captured information on women's participation in household decision-making, gender-related hurdles in accessing healthcare and women's .... estimated to account for the hierarchical structure of the data. In order to ...

  2. Stakeholders’ inclusion: more than a cup of tea? Measuring the performance of interactive decision making

    M. Ianniello; P. Fedele; L. Brusati

    2010-01-01

    Interactive decision making has become a recurrent practice, especially in local governments (Edelenbos, 1999; Klijn, 2008). Many administrations, in fact, involve citizens, social organizations and broadly speaking stakeholders, in the early stages of policy making, before the development of policy proposals (Kickert et al., 1997; McLaverty, 2002). The intended purpose is to adopt better and more democratic policy decisions, avoiding recurrent problems encountered in usua...

  3. Spectrophotometric and Refractometric Determination of Total Protein in Avian Plasma

    Rodica Căpriță

    2013-10-01

    Full Text Available The aim of this study was to compare the total protein values obtained in heparin plasma of chickens by a spectrophotometric technique (biuret method, and the values obtained on the same day in the same samples by refractometry. The results obtained by refractometry (average value 2.638±0.153g% were higher than those obtained by the spectrophotometric method (average value 2.441±0.181g%. There was a low correlation (r = 0.6709 between the total protein values, determined with both methods. Protein is the major determinant of plasma refractive index, but glucose contributes too. The refractometric method is not recommended in chickens for the determination of total protein, because avian blood glucose concentration averages about twice than in mammalian blood.

  4. Method development for arsenic analysis by modification in spectrophotometric technique

    M. A. Tahir

    2012-01-01

    Full Text Available Arsenic is a non-metallic constituent, present naturally in groundwater due to some minerals and rocks. Arsenic is not geologically uncommon and occurs in natural water as arsenate and arsenite. Additionally, arsenic may occur from industrial discharges or insecticide application. World Health Organization (WHO and Pakistan Standard Quality Control Authority have recommended a permissible limit of 10 ppb for arsenic in drinking water. Arsenic at lower concentrations can be determined in water by using high tech instruments like the Atomic Absorption Spectrometer (hydride generation. Because arsenic concentration at low limits of 1 ppb can not be determined easily with simple spectrophotometric technique, the spectrophotometric technique using silver diethyldithiocarbamate was modified to achieve better results, up to the extent of 1 ppb arsenic concentration.

  5. Spectrophotometric determination of silica in water. Low range

    Acosta L, E.

    1992-07-01

    The spectrophotometric method for the determination of the silica element in water, demineralized water, raw waters, laundry waters, waters treated with ion exchange resins and sea waters is described. This method covers the determination of the silica element in the interval from 20 to 1000 μg/l on 50 ml. of base sample. These limits its can be variable if the size of the used aliquot one is changed for the final determination of the silica element. (Author)

  6. Spectrophotometric determination of thorium using arsenazo III in water

    Rio, M.A.P. do; Godoy, J.M. de.

    1985-01-01

    A spectrophotometric determination of thorium with arsenazo III (1,8 dihidroxynaphtaline - 3,6 sulfanic acid - 2,7 bis (azo-2) - phenil argonic acid) was carried out aiming to analyse this element in water. In order to eliminate possible interferences, a coprecipitation with lantanium fluoride was used followed by an extration with 0,2 M TTA (tenoil-trifluor - aceton) / Benzen. The results showed a good agreement with the ones obtained by alfa-spectrometry. (Author) [pt

  7. SPECTROPHOTOMETRIC ASSESSMENT OF FERRIC REDUCING POWER OF THE INSTANT COFFEE

    Tsiupko, T. G.; Tishchenko, E. A.; Voronova, O. B.

    2016-01-01

    The methods of antioxidant activity determination of foodstuffs using different indicator systems were discussed. The investigation of ferric reducing power (FRP) of coffee and its individual phenolic components such as chlorogenic (CGA), caffeic (СА), ferulic (FA), gallic (GA), vanillic (VA), protocatechuic (PCA) and uric (UA) acids as well as quercetin (Qu) and catechol (C) using the spectrophotometric method with Fe(III) - o-Phen indicator system was carried out. It was shown that the sens...

  8. A survey tool for measuring evidence-based decision making capacity in public health agencies

    Jacobs Julie A

    2012-03-01

    Full Text Available Abstract Background While increasing attention is placed on using evidence-based decision making (EBDM to improve public health, there is little research assessing the current EBDM capacity of the public health workforce. Public health agencies serve a wide range of populations with varying levels of resources. Our survey tool allows an individual agency to collect data that reflects its unique workforce. Methods Health department leaders and academic researchers collaboratively developed and conducted cross-sectional surveys in Kansas and Mississippi (USA to assess EBDM capacity. Surveys were delivered to state- and local-level practitioners and community partners working in chronic disease control and prevention. The core component of the surveys was adopted from a previously tested instrument and measured gaps (importance versus availability in competencies for EBDM in chronic disease. Other survey questions addressed expectations and incentives for using EBDM, self-efficacy in three EBDM skills, and estimates of EBDM within the agency. Results In both states, participants identified communication with policymakers, use of economic evaluation, and translation of research to practice as top competency gaps. Self-efficacy in developing evidence-based chronic disease control programs was lower than in finding or using data. Public health practitioners estimated that approximately two-thirds of programs in their agency were evidence-based. Mississippi participants indicated that health department leaders' expectations for the use of EBDM was approximately twice that of co-workers' expectations and that the use of EBDM could be increased with training and leadership prioritization. Conclusions The assessment of EBDM capacity in Kansas and Mississippi built upon previous nationwide findings to identify top gaps in core competencies for EBDM in chronic disease and to estimate a percentage of programs in U.S. health departments that are evidence

  9. Spectro-photometric determinations of Mn, Fe and Cu in aluminum master alloys

    Rehan; Naveed, A.; Shan, A.; Afzal, M.; Saleem, J.; Noshad, M. A.

    2016-08-01

    Highly reliable, fast and cost effective Spectro-photometric methods have been developed for the determination of Mn, Fe & Cu in aluminum master alloys, based on the development of calibration curves being prepared via laboratory standards. The calibration curves are designed so as to induce maximum sensitivity and minimum instrumental error (Mn 1mg/100ml-2mg/100ml, Fe 0.01mg/100ml-0.2mg/100ml and Cu 2mg/100ml-10mg/ 100ml). The developed Spectro-photometric methods produce accurate results while analyzing Mn, Fe and Cu in certified reference materials. Particularly, these methods are suitable for all types of Al-Mn, Al-Fe and Al-Cu master alloys (5%, 10%, 50% etc. master alloys).Moreover, the sampling practices suggested herein include a reasonable amount of analytical sample, which truly represent the whole lot of a particular master alloy. Successive dilution technique was utilized to meet the calibration curve range. Furthermore, the workout methods were also found suitable for the analysis of said elements in ordinary aluminum alloys. However, it was observed that Cush owed a considerable interference with Fe, the later one may not be accurately measured in the presence of Cu greater than 0.01 %.

  10. Spectrophotometric determination of nitrite by its catalytic effect on the oxidation of congo red with bromate

    Zenovia Moldovan

    2012-08-01

    Full Text Available A novel simple, sensitive and rapid kinetic-spectrophotometric method for the determination of trace amounts of nitrite is proposed. The method is based on its catalytic effect on the oxidation of congo red (CR by potassium bromate in acidic solution. The oxidation reaction is monitored spectrophotometrically by measuring the decrease in the absorbance of CR at a suitable λmax = 570 nm for the first 10–40 s from the start of the reaction. Under the optimum experimental conditions (sulfuric acid, 0.3 M; CR, 0.75Χ10-4 M; potassium bromate, 5Χ10-4 M and 25 oC, nitrite can be determined in the range of 0.015–0.75 µg mL−1 with the detection limit of 0.006 µg mL−1. The relative standard deviation of five replicate determination of 0.25 µg mL−1 nitrite was 2.5%. The proposed method was applied satisfactorily to the determination of nitrite in spiked drinking water samples.DOI: http://dx.doi.org/10.4314/bcse.v26i2.1

  11. Indirect spectrophotometric determination of arbutin, whitening agent through oxidation by periodate and complexation with ferric chloride

    Barsoom, B. N.; Abdelsamad, A. M. E.; Adib, N. M.

    2006-07-01

    A simple and accurate spectrophotometric method for the determination of arbutin (glycosylated hydroquinone) is described. It is based on the oxidation of arbutin by periodate in presence of iodate. Excess periodate causes liberation of iodine at pH 8.0. The unreacted periodate is determined by measurement of the liberated iodine spectrophotometrically in the wavelength range (300-500 nm). A calibration curve was constructed for more accurate results and the correlation coefficient of linear regression analysis was -0.9778. The precision of this method was better than 6.17% R.S.D. ( n = 3). Regression analysis of Bear-Lambert plot shows good correlation in the concentration range 25-125 ug/ml. The identification limit was determined to be 25 ug/ml a detailed study of the reaction conditions was carried out, including effect of changing pH, time, temperature and volume of periodate. Analyzing pure and authentic samples containing arbutin tested the validity of the proposed method which has an average percent recovery of 100.86%. An alternative method is also proposed which involves a complexation reaction between arbutin and ferric chloride solution. The produced complex which is yellowish-green in color was determined spectophotometrically.

  12. A novel method for spectrophotometric determination of pregabalin in pure form and in capsules

    Gaur Prateek

    2011-10-01

    Full Text Available Abstract Background Pregabalin, a γ-amino-n-butyric acid derivative, is an antiepileptic drug not yet official in any pharmacopeia and development of analytical procedures for this drug in bulk/formulation forms is a necessity. We herein, report a new, simple, extraction free, cost effective, sensitive and reproducible spectrophotometric method for the determination of the pregabalin. Results Pregabalin, as a primary amine was reacted with ninhydrin in phosphate buffer pH 7.4 to form blue violet colored chromogen which could be measured spectrophotometrically at λmax 402.6 nm. The method was validated with respect to linearity, accuracy, precision and robustness. The method showed linearity in a wide concentration range of 50-1000 μg mL-1 with good correlation coefficient (0.992. The limits of assays detection was found to be 6.0 μg mL-1 and quantitation limit was 20.0 μg mL-1. The suggested method was applied to the determination of the drug in capsules. No interference could be observed from the additives in the capsules. The percentage recovery was found to be 100.43 ± 1.24. Conclusion The developed method was successfully validated and applied to the determination of pregabalin in bulk and pharmaceutical formulations without any interference from common excipients. Hence, this method can be potentially useful for routine laboratory analysis of pregabalin.

  13. Alanine dosimetry using a spectrophotometric ferric-xylenol orange complex readout

    Laere, K. van; Buysse, J.; Berkvens, P.

    1989-01-01

    The spectrophotometric dosimetric method using the indirect oxidation of ferrous ions after dissolution of irradiated DL-and L-alanine has been thoroughly investigated with respect to its composition, read-out procedure and dose-response. Optimal concentration of 0.10 N H 2 SO 4 , 0.2 mM xylenol orange and 0.2 mM Fe 2+ were found, giving an absorption maximum at 547 nm. Standardization of chemical processing procedures allows a reproducibility better than 0.5%. The useful dose range has been extended to 0.03-12 kGy by means of slightly different read-out procedure. The quantitative concept of ''indirect yield'', G id , was introduced for this procedure as a measure of the indirect oxidation capacity of the radicals. It was found to be G id,0 (Fe 3+ ) 7.1 ions/100 eV transferred into the alanine. The spectrophotometric readout combines the highly advantageous use of alanine as a dosemeter with the straightforwardness, accuracy and low costs of the chemical procedure. (author)

  14. Batch and flow-injection methods for the spectrophotometric determination of olanzapine

    Jasinska, A.; Nalewajko, E

    2004-04-22

    An indirect batch spectrophotometric and direct flow-injection (FI) visible spectrophotometric methods have been developed for the determination of the novel anti-psychotic drug olanzapine (OLA). The batch method is based on the oxidation of olanzapine by a known excess of potassium hexacyanoferrate(III) in the presence of the mixture of sulphuric and phosphoric acids (1:1 (v/v)). The absorbance of unreacted oxidant is measured at 425 nm. The absorbance decreases linearly with increasing concentration of the assayed drug. The FI method with detection at 540 nm is based on the direct oxidation of olanzapine one of two oxidants, cerium(IV) sulphate or potassium hexacyanoferrate(III) in acidic medium. The calibration graph were linear over the range of 2.5-40 {mu}g ml{sup -1} in the batch method and 0.05-300 and 0.5-250 {mu}g ml{sup -1} in the FI methods, used cerium (IV) sulphate and potassium hexacyanoferrate (III) respectively. Both FI methods gave similar results in terms of precision and accuracy. The relative standard deviation (R.S.D.), was <1%. The accuracy, obtained from recovery experiments, was 97.9-99.4%. The batch method gave slightly higher R.S.D. values (up to 2.3%) and lower values of accuracy (the recovery was between 96.5 and 96.6%). The methods developed were applied to the determination of olanzapine in a pharmaceutical product.

  15. Spectrophotometric Determination of Phenolic Antioxidants in the Presence of Thiols and Proteins

    Aslı Neslihan Avan

    2016-08-01

    Full Text Available Development of easy, practical, and low-cost spectrophotometric methods is required for the selective determination of phenolic antioxidants in the presence of other similar substances. As electron transfer (ET-based total antioxidant capacity (TAC assays generally measure the reducing ability of antioxidant compounds, thiols and phenols cannot be differentiated since they are both responsive to the probe reagent. In this study, three of the most common TAC determination methods, namely cupric ion reducing antioxidant capacity (CUPRAC, 2,2′-azinobis(3-ethylbenzothiazoline-6-sulfonic acid diammonium salt/trolox equivalent antioxidant capacity (ABTS/TEAC, and ferric reducing antioxidant power (FRAP, were tested for the assay of phenolics in the presence of selected thiol and protein compounds. Although the FRAP method is almost non-responsive to thiol compounds individually, surprising overoxidations with large positive deviations from additivity were observed when using this method for (phenols + thiols mixtures. Among the tested TAC methods, CUPRAC gave the most additive results for all studied (phenol + thiol and (phenol + protein mixtures with minimal relative error. As ABTS/TEAC and FRAP methods gave small and large deviations, respectively, from additivity of absorbances arising from these components in mixtures, mercury(II compounds were added to stabilize the thiol components in the form of Hg(II-thiol complexes so as to enable selective spectrophotometric determination of phenolic components. This error compensation was most efficient for the FRAP method in testing (thiols + phenols mixtures.

  16. Measuring Personality in Context: Improving Predictive Accuracy in Selection Decision Making

    Hoffner, Rebecca Ann

    2009-01-01

    This study examines the accuracy of a context-sensitive (i.e., goal dimensions) measure of personality compared to a traditional measure of personality (NEO-PI-R) and generalized self-efficacy (GSE) to predict variance in task performance. The goal dimensions measure takes a unique perspective in the conceptualization of personality. While traditional measures differentiate within person and collapse across context (e.g., Big Five), the goal dimensions measure employs a hierarchical structure...

  17. SHARDS: AN OPTICAL SPECTRO-PHOTOMETRIC SURVEY OF DISTANT GALAXIES

    Pérez-González, Pablo G.; Cava, Antonio; Barro, Guillermo; Villar, Víctor; Cardiel, Nicolás; Espino, Néstor; Gallego, Jesús; Ferreras, Ignacio; Rodríguez-Espinosa, José Miguel; Balcells, Marc; Cepa, Jordi; Alonso-Herrero, Almudena; Cenarro, Javier; Charlot, Stéphane; Cimatti, Andrea; Conselice, Christopher J.; Daddi, Emmanuele; Elbaz, David; Donley, Jennifer; Gobat, R.

    2013-01-01

    We present the Survey for High-z Absorption Red and Dead Sources (SHARDS), an ESO/GTC Large Program carried out using the OSIRIS instrument on the 10.4 m Gran Telescopio Canarias (GTC). SHARDS is an ultra-deep optical spectro-photometric survey of the GOODS-N field covering 130 arcmin 2 at wavelengths between 500 and 950 nm with 24 contiguous medium-band filters (providing a spectral resolution R ∼ 50). The data reach an AB magnitude of 26.5 (at least at a 3σ level) with sub-arcsec seeing in all bands. SHARDS' main goal is to obtain accurate physical properties of intermediate- and high-z galaxies using well-sampled optical spectral energy distributions (SEDs) with sufficient spectral resolution to measure absorption and emission features, whose analysis will provide reliable stellar population and active galactic nucleus (AGN) parameters. Among the different populations of high-z galaxies, SHARDS' principal targets are massive quiescent galaxies at z > 1, whose existence is one of the major challenges facing current hierarchical models of galaxy formation. In this paper, we outline the observational strategy and include a detailed discussion of the special reduction and calibration procedures which should be applied to the GTC/OSIRIS data. An assessment of the SHARDS data quality is also performed. We present science demonstration results on the detection and study of emission-line galaxies (star-forming objects and AGNs) at z = 0-5. We also analyze the SEDs for a sample of 27 quiescent massive galaxies with spectroscopic redshifts in the range 1.0 < z ∼< 1.4. We discuss the improvements introduced by the SHARDS data set in the analysis of their star formation history and stellar properties. We discuss the systematics arising from the use of different stellar population libraries, typical in this kind of study. Averaging the results from the different libraries, we find that the UV-to-MIR SEDs of the massive quiescent galaxies at z = 1.0-1.4 are well

  18. SHARDS: An Optical Spectro-photometric Survey of Distant Galaxies

    Pérez-González, Pablo G.; Cava, Antonio; Barro, Guillermo; Villar, Víctor; Cardiel, Nicolás; Ferreras, Ignacio; Rodríguez-Espinosa, José Miguel; Alonso-Herrero, Almudena; Balcells, Marc; Cenarro, Javier; Cepa, Jordi; Charlot, Stéphane; Cimatti, Andrea; Conselice, Christopher J.; Daddi, Emmanuele; Donley, Jennifer; Elbaz, David; Espino, Néstor; Gallego, Jesús; Gobat, R.; González-Martín, Omaira; Guzmán, Rafael; Hernán-Caballero, Antonio; Muñoz-Tuñón, Casiana; Renzini, Alvio; Rodríguez-Zaurín, Javier; Tresse, Laurence; Trujillo, Ignacio; Zamorano, Jaime

    2013-01-01

    We present the Survey for High-z Absorption Red and Dead Sources (SHARDS), an ESO/GTC Large Program carried out using the OSIRIS instrument on the 10.4 m Gran Telescopio Canarias (GTC). SHARDS is an ultra-deep optical spectro-photometric survey of the GOODS-N field covering 130 arcmin2 at wavelengths between 500 and 950 nm with 24 contiguous medium-band filters (providing a spectral resolution R ~ 50). The data reach an AB magnitude of 26.5 (at least at a 3σ level) with sub-arcsec seeing in all bands. SHARDS' main goal is to obtain accurate physical properties of intermediate- and high-z galaxies using well-sampled optical spectral energy distributions (SEDs) with sufficient spectral resolution to measure absorption and emission features, whose analysis will provide reliable stellar population and active galactic nucleus (AGN) parameters. Among the different populations of high-z galaxies, SHARDS' principal targets are massive quiescent galaxies at z > 1, whose existence is one of the major challenges facing current hierarchical models of galaxy formation. In this paper, we outline the observational strategy and include a detailed discussion of the special reduction and calibration procedures which should be applied to the GTC/OSIRIS data. An assessment of the SHARDS data quality is also performed. We present science demonstration results on the detection and study of emission-line galaxies (star-forming objects and AGNs) at z = 0-5. We also analyze the SEDs for a sample of 27 quiescent massive galaxies with spectroscopic redshifts in the range 1.0 UV-to-MIR SEDs of the massive quiescent galaxies at z = 1.0-1.4 are well described by an exponentially decaying star formation history with scale τ = 100-200 Myr, age around 1.5-2.0 Gyr, solar or slightly sub-solar metallicity, and moderate extinction, A(V) ~ 0.5 mag. We also find that galaxies with masses above M* are typically older than lighter galaxies, as expected in a downsizing scenario of galaxy formation. This

  19. SHARDS: AN OPTICAL SPECTRO-PHOTOMETRIC SURVEY OF DISTANT GALAXIES

    Perez-Gonzalez, Pablo G.; Cava, Antonio; Barro, Guillermo; Villar, Victor; Cardiel, Nicolas; Espino, Nestor; Gallego, Jesus [Departamento de Astrofisica, Facultad de CC. Fisicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Ferreras, Ignacio [Mullard Space Science Laboratory, University College London, Holmbury St Mary, Dorking, Surrey RH5 6NT (United Kingdom); Rodriguez-Espinosa, Jose Miguel; Balcells, Marc; Cepa, Jordi [Instituto de Astrofisica de Canarias, E-38200 La Laguna, Tenerife (Spain); Alonso-Herrero, Almudena [Instituto de Fisica de Cantabria, CSIC-Universidad de Cantabria, E-39005 Santander (Spain); Cenarro, Javier [Centro de Estudios de Fisica del Cosmos de Aragon, Plaza San Juan 1, Planta 2, E-44001 Teruel (Spain); Charlot, Stephane [Institut d' Astrophysique de Paris, CNRS, Universite Pierre and Marie Curie, UMR 7095, 98bis bd Arago, F-75014 Paris (France); Cimatti, Andrea [Dipartimento di Astronomia, Universita degli Studi di Bologna, I-40127 Bologna (Italy); Conselice, Christopher J. [School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD (United Kingdom); Daddi, Emmanuele; Elbaz, David [CEA, Laboratoire AIM, Irfu/SAp, F-91191 Gif-sur-Yvette (France); Donley, Jennifer [Los Alamos National Laboratory, Los Alamos, NM (United States); Gobat, R. [Laboratoire AIM-Paris-Saclay, CEA/DSM-CNRS-Universite Paris Diderot, Irfu/Service d' Astrophysique, CEA Saclay, Orme des Merisiers, F-91191 Gif-sur-Yvette (France); and others

    2013-01-01

    We present the Survey for High-z Absorption Red and Dead Sources (SHARDS), an ESO/GTC Large Program carried out using the OSIRIS instrument on the 10.4 m Gran Telescopio Canarias (GTC). SHARDS is an ultra-deep optical spectro-photometric survey of the GOODS-N field covering 130 arcmin{sup 2} at wavelengths between 500 and 950 nm with 24 contiguous medium-band filters (providing a spectral resolution R {approx} 50). The data reach an AB magnitude of 26.5 (at least at a 3{sigma} level) with sub-arcsec seeing in all bands. SHARDS' main goal is to obtain accurate physical properties of intermediate- and high-z galaxies using well-sampled optical spectral energy distributions (SEDs) with sufficient spectral resolution to measure absorption and emission features, whose analysis will provide reliable stellar population and active galactic nucleus (AGN) parameters. Among the different populations of high-z galaxies, SHARDS' principal targets are massive quiescent galaxies at z > 1, whose existence is one of the major challenges facing current hierarchical models of galaxy formation. In this paper, we outline the observational strategy and include a detailed discussion of the special reduction and calibration procedures which should be applied to the GTC/OSIRIS data. An assessment of the SHARDS data quality is also performed. We present science demonstration results on the detection and study of emission-line galaxies (star-forming objects and AGNs) at z = 0-5. We also analyze the SEDs for a sample of 27 quiescent massive galaxies with spectroscopic redshifts in the range 1.0 < z {approx}< 1.4. We discuss the improvements introduced by the SHARDS data set in the analysis of their star formation history and stellar properties. We discuss the systematics arising from the use of different stellar population libraries, typical in this kind of study. Averaging the results from the different libraries, we find that the UV-to-MIR SEDs of the massive quiescent galaxies at

  20. An Information Theoretic Approach for Measuring Data Discovery and Utilization During Analytical and Decision Making Processes

    2015-07-31

    and make the expected decision outcomes. The scenario is based around a scripted storyboard where an organized crime network is operating in a city to...interdicted by law enforcement to disrupt the network. The scenario storyboard was used to develop a probabilistic vehicle traffic model in order to

  1. The vexing problem of defining the meaning, role and measurement of values in treatment decision-making.

    Charles, Cathy; Gafni, Amiram

    2014-03-01

    Two international movements, evidence-based medicine (EBM) and shared decision-making (SDM) have grappled for some time with issues related to defining the meaning, role and measurement of values/preferences in their respective models of treatment decision-making. In this article, we identify and describe unresolved problems in the way that each movement addresses these issues. The starting point for this discussion is that at least two essential ingredients are needed for treatment decision-making: research information about treatment options and their potential benefits and risks; and the values/preferences of participants in the decision-making process. Both the EBM and SDM movements have encountered difficulties in defining the meaning, role and measurement of values/preferences in treatment decision-making. In the EBM model of practice, there is no clear and consistent definition of patient values/preferences and no guidance is provided on how to integrate these into an EBM model of practice. Methods advocated to measure patient values are also problematic. Within the SDM movement, patient values/preferences tend to be defined and measured in a restrictive and reductionist way as patient preferences for treatment options or attributes of options, while broader underlying value structures are ignored. In both models of practice, the meaning and expected role of physician values in decision-making are unclear. Values clarification exercises embedded in patient decision aids are suggested by SDM advocates to identify and communicate patient values/preferences for different treatment outcomes. Such exercises have the potential to impose a particular decision-making theory and/or process onto patients, which can change the way they think about and process information, potentially impeding them from making decisions that are consistent with their true values. The tasks of clarifying the meaning, role and measurement of values/preferences in treatment decision-making

  2. Decision-making in follow-up after endovascular aneurysm repair based on diameter and volume measurements : a blinded comparison

    Prinssen, M; Verhoeven, ELG; Verhagen, HJM; Blankensteijn, JD

    Objective: to assess whether volume, in addition to diameter, measurements facilitate decision-making after endovascular aneurysm repair (EVAR). Material/Methods: patients (n = 82) with an immediately post-EVAR, and at least one follow-up (3-60 months), computed tomographic angiogram (CTA) were

  3. Adjusted Poverty Measures and the Distribution of Title I Aid: Does Title I Really Make the Rich States Richer?

    Baker, Bruce D.; Taylor, Lori; Levin, Jesse; Chambers, Jay; Blankenship, Charles

    2013-01-01

    Federal and state governments in the United States make extensive use of student poverty rates in compensatory aid programs like Title I. Unfortunately, the measures of student poverty that drive funding allocations under such programs are biased because they fail to reflect geographic differences in the cost of living. In this study, we construct…

  4. Patients' and observers' perceptions of involvement differ. Validation study on inter-relating measures for shared decision making.

    Kasper, Jürgen; Heesen, Christoph; Köpke, Sascha; Fulcher, Gary; Geiger, Friedemann

    2011-01-01

    Patient involvement into medical decisions as conceived in the shared decision making method (SDM) is essential in evidence based medicine. However, it is not conclusively evident how best to define, realize and evaluate involvement to enable patients making informed choices. We aimed at investigating the ability of four measures to indicate patient involvement. While use and reporting of these instruments might imply wide overlap regarding the addressed constructs this assumption seems questionable with respect to the diversity of the perspectives from which the assessments are administered. The study investigated a nested cohort (N = 79) of a randomized trial evaluating a patient decision aid on immunotherapy for multiple sclerosis. Convergent validities were calculated between observer ratings of videotaped physician-patient consultations (OPTION) and patients' perceptions of the communication (Shared Decision Making Questionnaire, Control Preference Scale & Decisional Conflict Scale). OPTION reliability was high to excellent. Communication performance was low according to OPTION and high according to the three patient administered measures. No correlations were found between observer and patient judges, neither for means nor for single items. Patient report measures showed some moderate correlations. Existing SDM measures do not refer to a single construct. A gold standard is missing to decide whether any of these measures has the potential to indicate patient involvement. Pronounced heterogeneity of the underpinning constructs implies difficulties regarding the interpretation of existing evidence on the efficacy of SDM. Consideration of communication theory and basic definitions of SDM would recommend an inter-subjective focus of measurement. Controlled-Trials.com ISRCTN25267500.

  5. When it comes to measuring value, few HMOs can make the grade.

    MacStravic, S

    2001-01-01

    Like all organizations, managed care organizations (MCOs) must deliver value to customers, and to be sure of keeping them, ensure those customers know they have gained value. MCOs can choose any mix of insurance, protection, or experience value from particular encounters with customers, or durable value from their relationship with customers. Many have done a good job of tracking and enabling employers to appreciate the impact they have had on business performance, but few have done the same for the health and quality-of-life they deliver to consumers. MCOs already participate in the delivery of significant and enduring life value to consumers. It makes sense to track and remind consumers of the positive differences MCOs make, and thereby obtain member satisfaction, retention, and loyalty benefits, as well as image improvements for managed care as a whole. Some simple and inexpensive options for both tracking and reminding consumers are offered for consideration, including personalized annual health reports.

  6. Defining and Measuring Decision-Making for the Management of Trauma Patients.

    Madani, Amin; Gips, Amanda; Razek, Tarek; Deckelbaum, Dan L; Mulder, David S; Grushka, Jeremy R

    Effective management of trauma patients is heavily dependent on sound judgment and decision-making. Yet, current methods for training and assessing these advanced cognitive skills are subjective, lack standardization, and are prone to error. This qualitative study aims to define and characterize the cognitive and interpersonal competencies required to optimally manage injured patients. Cognitive and hierarchical task analyses for managing unstable trauma patients were performed using qualitative methods to map the thoughts, behaviors, and practices that characterize expert performance. Trauma team leaders and board-certified trauma surgeons participated in semistructured interviews that were transcribed verbatim. Data were supplemented with content from published literature and prospectively collected field notes from observations of the trauma team during trauma activations. The data were coded and analyzed using grounded theory by 2 independent reviewers. A framework was created based on 14 interviews with experts (lasting 1-2 hours each), 35 field observations (20 [57%] blunt; 15 [43%] penetrating; median Injury Severity Score 20 [13-25]), and 15 literary sources. Experts included 11 trauma surgeons and 3 emergency physicians from 7 Level 1 academic institutions in North America (median years in practice: 12 [8-17]). Twenty-nine competencies were identified, including 17 (59%) related to situation awareness, 6 (21%) involving decision-making, and 6 (21%) requiring interpersonal skills. Of 40 potential errors that were identified, root causes were mapped to errors in situation awareness (20 [50%]), decision-making (10 [25%]), or interpersonal skills (10 [25%]). This study defines cognitive and interpersonal competencies that are essential for the management of trauma patients. This framework may serve as the basis for novel curricula to train and assess decision-making skills, and to develop quality-control metrics to improve team and individual performance

  7. Method to make accurate concentration and isotopic measurements for small gas samples

    Palmer, M. R.; Wahl, E.; Cunningham, K. L.

    2013-12-01

    Carbon isotopic ratio measurements of CO2 and CH4 provide valuable insight into carbon cycle processes. However, many of these studies, like soil gas, soil flux, and water head space experiments, provide very small gas sample volumes, too small for direct measurement by current constant-flow Cavity Ring-Down (CRDS) isotopic analyzers. Previously, we addressed this issue by developing a sample introduction module which enabled the isotopic ratio measurement of 40ml samples or smaller. However, the system, called the Small Sample Isotope Module (SSIM), does dilute the sample during the delivery with inert carrier gas which causes a ~5% reduction in concentration. The isotopic ratio measurements are not affected by this small dilution, but researchers are naturally interested accurate concentration measurements. We present the accuracy and precision of a new method of using this delivery module which we call 'double injection.' Two portions of the 40ml of the sample (20ml each) are introduced to the analyzer, the first injection of which flushes out the diluting gas and the second injection is measured. The accuracy of this new method is demonstrated by comparing the concentration and isotopic ratio measurements for a gas sampled directly and that same gas measured through the SSIM. The data show that the CO2 concentration measurements were the same within instrument precision. The isotopic ratio precision (1σ) of repeated measurements was 0.16 permil for CO2 and 1.15 permil for CH4 at ambient concentrations. This new method provides a significant enhancement in the information provided by small samples.

  8. Titrimetric and Spectrophotometric Determination of Metaprolol tartrate in Pharmaceuticals Using N-Bromosuccinimide

    K. Basavaiah

    2007-01-01

    Full Text Available One titrimetric and two spectrophotometric methods are presented for the assay of metaprolol tartrate (MPT in bulk drug and in tablets. The methods employ N-bromosuccinimide (NBS as the oxidimetric reagent and two dyes, methyl orange and indigo carmine as spectrophotometric reagents. In titrimetry, an acidified solution of MPT is treated with a known excess amount of NBS and after a definite time, the unreacted oxidant is determined by iodometric back titration. Spectrophotometry involves adding a measured excess of NBS to MPT in acid medium followed by determination of residual NBS by reacting with a fixed amount of either methyl orange and measuring the absorbance at 520 nm (Method A or indigo carmine and measuring the absorbance at 610 nm (Method B. In all the methods, the amount of NBS reacted corresponds to the amount of MPT. Reaction conditions have been optimized. Titrimetry allows the determination of 1 - 12 mg of MPT and the calculations are based on a 1: 4 (MPT: NBS reaction stoichiometry. In spectrophotometry, the measured absorbance is found to increase linearly with the concentration of MPT serving as basis for quantitation. The systems obey Beer’s law for 0.5 - 4.0 μg mL-1 and 1.25 - 10.0 μg mL-1 for method A and method B, respectively. The apparent absorptivities are calculated to 1.07 × 105 be and 4.22 × 104 L mol cm-1 for method A and method B, respectively. The methods developed were applied to the assay of MPT in commercial tablet formulations, and the results were compared statistically with those of a reference method. The accuracy and reliability of the methods were further ascertained by performing recovery tests via standard-addition method.

  9. Challenges in Measuring Cost and Value in Oncology: Making It Personal.

    Yu, Peter P

    2016-01-01

    Oncology patients often find themselves facing an incurable disease with limited treatment options and increasing patient fragility. The importance of patient preferences and values increases in shared decision making especially when the cost of cancer care is continuing its steep rise. As our understanding of cancer systems biology increases, we are justifiably optimistic about therapeutic improvements but recognize that this has complicated the traditional Food and Drug Administration approval of drug indications based on organ-specific cancer for a particular drug. Dynamic and agile clinical guidelines that reflect a rapidly changing knowledge base for decision-making support are needed. The American Society of Clinical Oncology (ASCO) has been working on three initiatives to tackle these complex issues. The first initiative is ASCO's collaboration with other international organizations to create a framework to assess drugs for the World Health Organization's Essential Medicines List, including nongenerics. The second initiative aims to define clinically meaningful outcomes as precision medicine expands the definition of cancers, leading to increased demand for the use of targeted drugs as single agents or in combination. The third initiative is ASCO's value framework, published in 2015, focusing on patient-physician shared decision making. The framework incorporates three parameters: 1) the meaningfulness of the clinical benefit, 2) the toxicity of the treatment, and 3) the patient's financial out-of-pocket cost. ASCO is concerned about the rising cost of cancer care when the clinical complexity and the pace of change in oncology are accelerating, and it is committed to help improve patient outcomes and value in cancer care as well as to engage the broader health care community in a process of collaborative improvement. Copyright © 2016 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  10. A simplified, improved method for making amplifier equivalent noise charge measurements using a new generation digitizing oscilloscope

    Zimmerman, T.

    1990-10-01

    Historically a variety of methods have been used to measure the equivalent noise charge (ENC) of amplifier/shaper systems for high energy physics. Some of these methods require several pieces of special test equipment and a fair amount of effort. The advent of digitizing oscilloscopes with statistics capabilities makes it possible to perform certain types of noise measurements accurately with very little effort. This paper describes the noise measurement method of a time invariant amplifier/shaper and of a time variant correlated sampling system, using a Tektronix DSA602 Digitizing Signal Analyzer. 4 figs

  11. Determining the psychometric properties of the Enhancing Decision-making Assessment in Midwifery (EDAM) measure in a cross cultural context.

    Jefford, Elaine; Jomeen, Julie; Martin, Colin R

    2016-04-28

    The ability to act on and justify clinical decisions as autonomous accountable midwifery practitioners, is encompassed within many international regulatory frameworks, yet decision-making within midwifery is poorly defined. Decision-making theories from medicine and nursing may have something to offer, but fail to take into consideration midwifery context and philosophy and the decisional autonomy of women. Using an underpinning qualitative methodology, a decision-making framework was developed, which identified Good Clinical Reasoning and Good Midwifery Practice as two conditions necessary to facilitate optimal midwifery decision-making during 2nd stage labour. This study aims to confirm the robustness of the framework and describe the development of Enhancing Decision-making Assessment in Midwifery (EDAM) as a measurement tool through testing of its factor structure, validity and reliability. A cross-sectional design for instrument development and a 2 (country; Australia/UK) x 2 (Decision-making; optimal/sub-optimal) between-subjects design for instrument evaluation using exploratory and confirmatory factor analysis, internal consistency and known-groups validity. Two 'expert' maternity panels, based in Australia and the UK, comprising of 42 participants assessed 16 midwifery real care episode vignettes using the empirically derived 26 item framework. Each item was answered on a 5 point likert scale based on the level of agreement to which the participant felt each item was present in each of the vignettes. Participants were then asked to rate the overall decision-making (optimal/sub-optimal). Post factor analysis the framework was reduced to a 19 item EDAM measure, and confirmed as two distinct scales of 'Clinical Reasoning' (CR) and 'Midwifery Practice' (MP). The CR scale comprised of two subscales; 'the clinical reasoning process' and 'integration and intervention'. The MP scale also comprised two subscales; women's relationship with the midwife' and 'general

  12. Spectrophotometric determination of zinc in impure solutions

    Rodriguez Hernandez, B.; Reyes Tamaral, A.

    1972-01-01

    A dithizone colorimetric method is described for determining zinc concentrations of 0.001 to 5 g/l in aqueous solutions from Rio Tinto Mines, containing copper, iron and other impurities. Citrate, cyanide and bis-2hydroxyethyl)-dithiocarbamate are added to the aqueous sample of masking several metals, and zinc is extracted at pH 5 with a solution of dithizone in carbon tetrachloride. Excess of dithizone is removed with sodium sulphide, and optical density of zinc dithionate in organic solution is measured at 5.35 nm. Calibration curves obey Beer's law up to 0.5 micro Zn/ml. (Author) 5 refs

  13. On a Consensus Measure in a Group Multi-Criteria Decision Making Problem.

    Michele Fedrizzi

    2010-01-01

    A method for consensus measuring in a group decision problem is presented for the multiple criteria case. The decision process is supposed to be carried out according to Saaty's Analytic Hierarchy Process, and hence using pairwise comparison among the alternatives. Using a suitable distance between the experts' judgements, a scale transformation is proposed which allows a fuzzy interpretation of the problem and the definition of a consensus measure by means of fuzzy tools as linguistic quanti...

  14. Cross Entropy Measures of Bipolar and Interval Bipolar Neutrosophic Sets and Their Application for Multi-Attribute Decision-Making

    Surapati Pramanik

    2018-03-01

    Full Text Available The bipolar neutrosophic set is an important extension of the bipolar fuzzy set. The bipolar neutrosophic set is a hybridization of the bipolar fuzzy set and neutrosophic set. Every element of a bipolar neutrosophic set consists of three independent positive membership functions and three independent negative membership functions. In this paper, we develop cross entropy measures of bipolar neutrosophic sets and prove their basic properties. We also define cross entropy measures of interval bipolar neutrosophic sets and prove their basic properties. Thereafter, we develop two novel multi-attribute decision-making strategies based on the proposed cross entropy measures. In the decision-making framework, we calculate the weighted cross entropy measures between each alternative and the ideal alternative to rank the alternatives and choose the best one. We solve two illustrative examples of multi-attribute decision-making problems and compare the obtained result with the results of other existing strategies to show the applicability and effectiveness of the developed strategies. At the end, the main conclusion and future scope of research are summarized.

  15. Spectrophotometric determination of volautile inorganic hydrides in binary gaseous mixtures

    Rezchikov, V.G.; Skachkova, I.N.; Kuznetsova, T.S.; Khrushcheva, V.V.

    1985-01-01

    A study was made on possibility of single and continuons analysis of binary mixtures (hydride-gas) for the content of volatile inorganic hydrides (VIH) from absorption spectra in the 185-280 nm band. Dependences of the percentage of VIH transmission on the wavelength are presented. It is shown that the maximum of their absorption depends on the element-hydrogen the bond length and binding energy. Detection limit for boron hydride was established to be n x 10 -3 % vol at 185-190 nm wavelength. Technique for spectrophotometric hydride determination in binary mixtures with hydrogen, argon, helium was developed. The technique provides the continuous control of gaseous mixture composition

  16. Spectrophotometric Determination of Thorium in Low Grade Minerals and Ores

    Arnfelt, A L; Edmundsson, I

    1960-08-15

    The following method is intended for the determination of microgram quantities of thorium in samples of minerals and ores. The mineral sample is decomposed by repeated sintering with sodium peroxide. After digestion with water thorium peroxide hydrate is recovered by centrifugation and dissolved in hydrochloric acid. Thorium is determined spectrophotometrically with naphtarson after its separation from metals forming chloro complexes which are adsorbed on a strongly basic anion exchange resin. Interferences from a few different ions have been studied. The time required for the analysis of one sample is about 4 hours, when analysing 12 samples simultaneously

  17. Spectrophotometric determination of the first hydrolysis constant of praseodymium (III)

    Gonzalez M, R.; Lopez G, H.; Rojas H, A.

    2010-01-01

    The behavior of the trivalent ion praseodymium in 2 M of NaCl at 303 K and in CO 2 free conditions, was studied. Spectrophotometric titrations of the soluble species were used, in order to obtain the value of the first hydrolysis constant of Pr(III). The data obtained were treated with both the program Squad and by a graphic method, respectively. The result obtained using Squad was log*β 1 = -8.94 ± 0.03, while it was log*β 1 = -8.77 ± 0.03, when calculated graphically. These results are similar to the value obtained previously with the potentiometric method. (Author)

  18. Spectrophotometric Determination of Thorium in Low Grade Minerals and Ores

    Arnfelt, A.L.; Edmundsson, I.

    1960-08-01

    The following method is intended for the determination of microgram quantities of thorium in samples of minerals and ores. The mineral sample is decomposed by repeated sintering with sodium peroxide. After digestion with water thorium peroxide hydrate is recovered by centrifugation and dissolved in hydrochloric acid. Thorium is determined spectrophotometrically with naphtarson after its separation from metals forming chloro complexes which are adsorbed on a strongly basic anion exchange resin. Interferences from a few different ions have been studied. The time required for the analysis of one sample is about 4 hours, when analysing 12 samples simultaneously

  19. Spectrophotometric determination of fluorides in water with Hach equipment

    Acosta L, E.

    1994-11-01

    The spectrophotometric method for the determination of the fluoride ion in water, demineralized water, raw waters, laundry waters and waters treated with ion exchange resins , using the technique and the SPADNS coloring indicated in the operation manual of the Hach equipment is described. This method covers the determination of the fluoride ion in the range from 0 to 2 mg/l on 25 ml. of radioactive base sample. These limits can be variable if the size of the used aliquot one is changed for the final determination of the fluoride ion. (Author)

  20. Model Multi Criteria Decision Making with Fuzzy ANP Method for Performance Measurement Small Medium Enterprise (SME)

    Rahmanita, E.; Widyaningrum, V. T.; Kustiyahningsih, Y.; Purnama, J.

    2018-04-01

    SMEs have a very important role in the development of the economy in Indonesia. SMEs assist the government in terms of creating new jobs and can support household income. The number of SMEs in Madura and the number of measurement indicators in the SME mapping so that it requires a method.This research uses Fuzzy Analytic Network Process (FANP) method for performance measurement SME. The FANP method can handle data that contains uncertainty. There is consistency index in determining decisions. Performance measurement in this study is based on a perspective of the Balanced Scorecard. This research approach integrated internal business perspective, learning, and growth perspective and fuzzy Analytic Network Process (FANP). The results of this research areframework a priority weighting of assessment indicators SME.

  1. Value Measurement Systems, Professional Narratives and the (Un)Making of Market Regimes in Twentieth-Century American Advertising

    Schwarzkopf, Stefan

    During the 1920s, consumer psychologists and market researchers began to develop measurement systems that allowed their clients to express in ‘hard’ figures, and thus to put a financial value on, the impact that particular advertisements had on consumers. At the same time, advertising designers...... owners, their clients and by media organizations which printed, aired or screened commercial messages. Drawing on the notion of the socio-technical ‘agencements’, and on theories of the performativity of measurement regimes in the making of markets, economic sociologists have developed a good...... understanding of how the act of measuring itself can affect the behaviour of those whose social actions are being measured. Much less well developed is an economic-sociological account of how such measurement regimes are being resisted and how and why they decline. This paper uses the rise and fall...

  2. Ideas on a practical method to make more uniform the measure and the account of doses

    Boussard, P.; Dollo, R.; De Kerviller, M.; Penneroux, M.

    1992-01-01

    The ICRP 60 publication and its consequences on the revision of CEC regulations and basic norms, discussions on dosimetry of outside workers and more generally on the development of exchanges of information between users have led EDF to question its practices for measuring counting doses. Faced with this wide range of french practices and in a desire for harmonisation, an EDF and CEA work team has established a summary of present methods, an evaluation of the consequences of these different strategies and have then suggested a harmonisation of dosimetric measures based on systematic methodology. (author)

  3. MEASURING COMPETITION FOR TEXTILES: DOES THE U.S. MAKE THE GRADE?

    Lyford, Conrad P.; Welch, J. Mark

    2004-01-01

    U.S. textile manufacturing is coming under increasing pressure from foreign competition. This paper evaluates the U.S. competitive position in the yarn segment using established quantifiable measures and provides an overall competitive assessment. The study found the industry in a relatively weak competitive position but that U.S. competitive position is improving.

  4. Pushing the limits of signal resolution to make coupling measurement easier.

    Herbert Pucheta, José Enrique; Pitoux, Daisy; Grison, Claire M; Robin, Sylvie; Merlet, Denis; Aitken, David J; Giraud, Nicolas; Farjon, Jonathan

    2015-05-07

    Probing scalar couplings are essential for structural elucidation in molecular (bio)chemistry. While the measurement of JHH couplings is facilitated by SERF experiments, overcrowded signals represent a significant limitation. Here, a new band selective pure shift SERF allows access to δ(1)H and JHH with an ultrahigh spectral resolution.

  5. CHALLENGES IN MEASURING A NEW CONSTRUCT : PERCEPTION OF VOLUNTARINESS FOR RESEARCH AND TREATMENT DECISION MAKING

    Miller, Victoria A.; Reynolds, William W.; Ittenbach, Richard F.; Luce, Mary Frances; Beauchamp, Tom L.; Nelson, Robert M.

    RELIABLE AND VALID MEASURES OF RELEVANT constructs are critical in the developing field of the empirical study of research ethics. The early phases of scale development for such constructs can be complex. We describe the methodological challenges of construct definition and operationalization and

  6. Application of Algebra Curriculum-Based Measurements for Decision Making in Middle and High School

    Johnson, Evelyn S.; Galow, Patricia A.; Allenger, Robert

    2013-01-01

    This article reports the results of a study examining the utility of curriculum-based measurement (CBM) in algebra for predicting performance on a state math assessment and informing instructional placement decisions for students in seventh, eighth, and tenth grades. Students completed six Basic Skills algebra probes across different time…

  7. Safety Assessment Approach for Decision Making Related to Remedial Measures and Radioactive Waste Management

    Rybalka, Nataliia; Kondratyev, Sergiy; Alekseeva, Zoya

    2016-01-01

    Conclusions: At each particular case of “legacy” radioactive waste management facilities the optimized remedial measures should be justified taken into account: • results of facility investigations; • site status and characteristics; • safety assessment; • economical reasons; • societal factors; • timeframes; • available technologies and techniques

  8. IMPROVED SPECTROPHOTOMETRIC CALIBRATION OF THE SDSS-III BOSS QUASAR SAMPLE

    Margala, Daniel; Kirkby, David [Frederick Reines Hall, Department of Physics and Astronomy, University of California, Irvine, CA (United States); Dawson, Kyle [Department of Physics and Astronomy, University of Utah, Salt Lake City, UT 84112 (United States); Bailey, Stephen [Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, CA 94720 (United States); Blanton, Michael [Center for Cosmology and Particle Physics, Department of Physics, New York University, 4 Washington Place, New York, NY 10003 (United States); Schneider, Donald P., E-mail: dmargala@uci.edu [Department of Astronomy and Astrophysics, The Pennsylvania State University, University Park, PA 16802 (United States)

    2016-11-10

    We present a model for spectrophotometric calibration errors in observations of quasars from the third generation of the Sloan Digital Sky Survey Baryon Oscillation Spectroscopic Survey (BOSS) and describe the correction procedure we have developed and applied to this sample. Calibration errors are primarily due to atmospheric differential refraction and guiding offsets during each exposure. The corrections potentially reduce the systematics for any studies of BOSS quasars, including the measurement of baryon acoustic oscillations using the Ly α forest. Our model suggests that, on average, the observed quasar flux in BOSS is overestimated by ∼19% at 3600 Å and underestimated by ∼24% at 10,000 Å. Our corrections for the entire BOSS quasar sample are publicly available.

  9. Optical spectrophotometric atlas of Supernova 1987A in the LMC. I. The first 130 days

    Phillips, M.M.; Heathcote, S.R.; Hamuy, M.; Navarrete, M.

    1988-01-01

    Optical spectrophotometry of SN 1987A in the Large Magellanic Cloud (LMC) covering the first 5 months since outburst is presented. More than 80 spectra were obtained at Cerro Tololo over this period, mostly with the 2D-Frutti two-dimensional photon-counting detector on the 1-m telescope. The spectrophotometric calibration of the 2D-Frutti data is considered in detail. Through a comparison with broadband photometry, it is shown that the accuracy of the 2D-Frutti spectrophotometry is + or - 5 percent in absolute terms, and that the relative calibration for any single spectrum is accurate to + or - 3 percent. CCD spectrophotometry obtained on the first night of observation (Feb. 25, 1987) is also briefly discussed. Radial velocities for several prominent absorption and emission features are measured from these combined data. 13 references

  10. Simultaneous determination of rifampicin, isoniazid and pyrazinamide in tablet preparations by multivariate spectrophotometric calibration.

    Goicoechea, H C; Olivieri, A C

    1999-08-01

    The use of multivariate spectrophotometric calibration is presented for the simultaneous determination of the active components of tablets used in the treatment of pulmonary tuberculosis. The resolution of ternary mixtures of rifampicin, isoniazid and pyrazinamide has been accomplished by using partial least squares (PLS-1) regression analysis. Although the components show an important degree of spectral overlap, they have been simultaneously determined with high accuracy and precision, rapidly and with no need of nonaqueous solvents for dissolving the samples. No interference has been observed from the tablet excipients. A comparison is presented with the related multivariate method of classical least squares (CLS) analysis, which is shown to yield less reliable results due to the severe spectral overlap among the studied compounds. This is highlighted in the case of isoniazid, due to the small absorbances measured for this component.

  11. Investigation of a New Spectrophotometric Method for the analysis of carbohydrates using glucose as model

    Hussain, Z.; Ali, A.; Shah, N.U.; Khan, K.M.

    2013-01-01

    Carbohydrates are biomolecule of significant importance. Its analysis is of prime importance in the clinical investigations, delivery of medicines and quality control operations of food and fuel products. Based on its importance a novel spectrophotometric method was investigated for the trace analysis of carbohydrates using glucose as model carbohydrate. This method is based on glucosazation followed by oxidation of the glucosazone with acidified iron (III) chloride. Oxidation of the glucsazone is necessary for enhancing the color intensity and optimum conditions were investigated for the process. All the absorbance measurements were carried out using 390 nm as gamma max. The ratio of the reactants was 1: 1.5: 0.1 mole for the glucose, phenyl hydrazine and iron (III) chloride. This method was used for the analysis of carbohydrates in real samples from plants, industrial products, blood and urine using glucose as reference. (author)

  12. Spectrophotometric determination of boron by solvent extraction with 2-hydroxy-2-methylbutyric acid and malachite green

    Sato, Shigeya; Uchikawa, Sumio

    1984-01-01

    A very simple and sensitive method for the spectrophotometric determination of boron was developed. Boron was found to react with 2-hydroxy-2-methylbutyric acid in weak acidic aqueous solution at room temperature to form a complex anion which can be extracted into chlorobenzene with malachite green in a single extraction; boron is determined indirectly by measuring the absorbance of malachite green in the extract at 629 nm. The calibration graph is linear over the range (7.50 x 10 -7 - 2.00 x 10 -5 ) mol dm -3 boron; the apparent molar absorptivity is 6.50 x 10 4 dm 3 mol -1 cm -1 . The method is applied to the determination of micro amounts of boron in natural waters with satisfactory results. (author)

  13. Spectrophotometric determination of boron by solvent extraction with 2-hydroxy-2-methylbutyric acid and malachite green

    Sato, Shigeya; Uchikawa, Sumio [Kumamoto Univ. (Japan). Faculty of Education

    1984-03-01

    A very simple and sensitive method for the spectrophotometric determination of boron was developed. Boron was found to react with 2-hydroxy-2-methylbutyric acid in weak acidic aqueous solution at room temperature to form a complex anion which can be extracted into chlorobenzene with malachite green in a single extraction; boron is determined indirectly by measuring the absorbance of malachite green in the extract at 629 nm. The calibration graph is linear over the range (7.50 x 10/sup -7/ - 2.00 x 10/sup -5/) mol dm/sup -3/ boron; the apparent molar absorptivity is 6.50 x 10/sup 4/ dm/sup 3/ mol/sup -1/ cm/sup -1/. The method is applied to the determination of micro amounts of boron in natural waters with satisfactory results.

  14. Development and application of spectrophotometric method for the determination of cefaclor in pharmaceutical formulations

    Asad Raza

    2009-01-01

    Full Text Available A simple, fast and sensitive spectrophotometric method for the determination of cefaclor in pharmaceutical raw and dosage forms based on reaction with ninhydrin is developed, optimized and validated. The purple color (Ruhemenn's purple that resulted from the reaction was stabilized and measured at 560 nm. Beer's law is obeyed in the concentration range of 4-80 µg mL-1 with molar absorptivity of 1.42 × 10(5 L mole-1 cm-1. All variables including the reagent concentration, heating time, reaction temperature, color stability period, and cefaclor/ninhydrin ratio were studied in order to optimize the reaction conditions. No interference was observed from common pharmaceutical adjuvant. The developed method is easy to use, accurate and highly cost-effective for routine studies relative to HPLC and other techniques.

  15. Development of microwave assisted spectrophotometric method for the determination of glucose

    Ali, Asif; Hussain, Zahid; Arain, Muhammad Balal; Shah, Nasrullah; Khan, Khalid Mohammad; Gulab, Hussain; Zada, Amir

    2016-01-01

    A spectrophotometric method was developed based on the microwave assisted synthesis of Maillard product. Various conditions of the reaction were optimized by varying the relative concentration of the reagents, operating temperature and volume of solutions used in the reaction in the microwave synthesizer. The absorbance of the microwave synthesized Maillard product was measured in the range of 360-740 nm using UV-Visible spectrophotometer. Based on the maximum absorbance, 370 nm was selected as the optimum wave length for further studies. The LOD and LOQ of glucose was found 3.08 μg mL- 1 and 9.33 μg mL- 1 with standard deviation of ± 0.05. The developed method was also applicable to urine sample.

  16. Selection of performance measure system as a base of airport operational control using multi criteria decision making approach

    Stevanović, Tatjana; Stanković, Jelena

    2012-01-01

    In contemporary's business environment, successful company must be socially responsible and environmentally conscientious in addition to essential tendency for maximizing profits, because only in this way can it ensure competitiveness in the market. Performance measuring of the airport is a critical management activity, which must be consistent with the goals, strategies and key success factors. Since the decision making is based on facts about considered task and their detailed analysis, the...

  17. Patients' and observers' perceptions of involvement differ. Validation study on inter-relating measures for shared decision making.

    Jürgen Kasper

    Full Text Available OBJECTIVE: Patient involvement into medical decisions as conceived in the shared decision making method (SDM is essential in evidence based medicine. However, it is not conclusively evident how best to define, realize and evaluate involvement to enable patients making informed choices. We aimed at investigating the ability of four measures to indicate patient involvement. While use and reporting of these instruments might imply wide overlap regarding the addressed constructs this assumption seems questionable with respect to the diversity of the perspectives from which the assessments are administered. METHODS: The study investigated a nested cohort (N = 79 of a randomized trial evaluating a patient decision aid on immunotherapy for multiple sclerosis. Convergent validities were calculated between observer ratings of videotaped physician-patient consultations (OPTION and patients' perceptions of the communication (Shared Decision Making Questionnaire, Control Preference Scale & Decisional Conflict Scale. RESULTS: OPTION reliability was high to excellent. Communication performance was low according to OPTION and high according to the three patient administered measures. No correlations were found between observer and patient judges, neither for means nor for single items. Patient report measures showed some moderate correlations. CONCLUSION: Existing SDM measures do not refer to a single construct. A gold standard is missing to decide whether any of these measures has the potential to indicate patient involvement. PRACTICE IMPLICATIONS: Pronounced heterogeneity of the underpinning constructs implies difficulties regarding the interpretation of existing evidence on the efficacy of SDM. Consideration of communication theory and basic definitions of SDM would recommend an inter-subjective focus of measurement. TRIAL REGISTRATION: Controlled-Trials.com ISRCTN25267500.

  18. A FMEA clinical laboratory case study: how to make problems and improvements measurable.

    Capunzo, Mario; Cavallo, Pierpaolo; Boccia, Giovanni; Brunetti, Luigi; Pizzuti, Sante

    2004-01-01

    The authors have experimented the application of the Failure Mode and Effect Analysis (FMEA) technique in a clinical laboratory. FMEA technique allows: a) to evaluate and measure the hazards of a process malfunction, b) to decide where to execute improvement actions, and c) to measure the outcome of those actions. A small sample of analytes has been studied: there have been determined the causes of the possible malfunctions of the analytical process, calculating the risk probability index (RPI), with a value between 1 and 1,000. Only for the cases of RPI > 400, improvement actions have been implemented that allowed a reduction of RPI values between 25% to 70% with a costs increment of FMEA technique can be applied to the processes of a clinical laboratory, even if of small dimensions, and offers a high potential of improvement. Nevertheless, such activity needs a thorough planning because it is complex, even if the laboratory already operates an ISO 9000 Quality Management System.

  19. A modified spectrophotometric assay to estimate deglycosylation of steroidal saponin to sapogenin by mixed ruminal microbes.

    Wang, Yuxi; McAllister, Tim A

    2010-08-30

    The lack of a method for measuring deglycosylation of saponins in ruminal fluid has limited the ability to investigate the impact of these compounds on rumen microorganisms. A simple spectrophotometric assay was adapted and a protocol developed to enable measurement of steroidal saponin and sapogenin in ruminal fluid. The procedure was used for in vitro determination of deglycosylation activity of rumen bacteria obtained from cattle fed or not fed Yucca schidigera saponin, and to determine the relative deglycosylase activities of extracellular and cell-associated enzymes from ruminal content. Modifications to the spectrophotometric assay (i.e. heating time shortened to 10 min and 0.5 mL dH(2)O added to the reaction mixture) improved the stability of the optical density (425 nm) of the chromophore for up to 24 h post-reaction. Centrifugation (12 000 x g, 20 min) enabled differential estimations of steroidal saponin and sapogenin in ruminal fluid. Steroidal saponin added to defaunated ruminal fluid (dRF) or clarified ruminal fluid (cRF) was recovered completely from the mixture as saponin + sapogenin (99.1% and 100.6%, respectively), whereas saponin recovery from the supernatant of dRF was greatly reduced (P ruminal extracellular enzyme preparation was recoverable in supernatant after 24 h, compared with only 26-32% remaining in supernatant from incubation with a cell-associated enzymes fraction. Mixed rumen bacteria deglycosylate steroidal saponin to sapogenin, at activity levels unaffected by prior exposure to saponin, but they were unable to degrade the sapogenin core structure. Deglycosylation activity occurred primarily in the cell-associated enzyme fraction of ruminal content. Copyright (c) 2008 Crown in the right of Canada. Published by John Wiley & Sons, Ltd.

  20. Don't bet on it! Wagering as a measure of awareness in decision making under uncertainty.

    Konstantinidis, Emmanouil; Shanks, David R

    2014-12-01

    Can our decisions be guided by unconscious or implicit influences? According to the somatic marker hypothesis, emotion-based signals can guide our decisions in uncertain environments outside awareness. Postdecision wagering, in which participants make wagers on the outcomes of their decisions, has been recently proposed as an objective and sensitive measure of conscious content. In 5 experiments we employed variations of a classic decision-making assessment, the Iowa Gambling Task, in combination with wagering in order to investigate the role played by unconscious influences. We examined the validity of postdecision wagering by comparing it with alternative measures of conscious knowledge, specifically confidence ratings and quantitative questions. Consistent with a putative role for unconscious influences, in Experiments 2 and 3 we observed a lag between choice accuracy and the onset of advantageous wagering. However, the lag was eliminated by a change in the wagering payoff matrix (Experiment 2) and by a switch from a binary wager response to either a binary or a 4-point confidence response (Experiment 3), and wagering underestimated awareness compared to explicit quantitative questions (Experiments 1 and 4). Our results demonstrate the insensitivity of postdecision wagering as a direct measure of conscious knowledge and challenge the claim that implicit processes influence decision making under uncertainty. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  1. Commentary: moving toward cost-effectiveness in using psychophysiological measures in clinical assessment: validity, decision making, and adding value.

    Youngstrom, Eric A; De Los Reyes, Andres

    2015-01-01

    Psychophysiological measures offer a variety of potential advantages, including more direct assessment of certain processes, as well as provision of information that may contrast with other sources. The role of psychophysiological measures in clinical practice will be best defined when researchers (a) switch to research designs and statistical models that better approximate how clinicians administer assessments and make clinical decisions in practice, (b) systematically compare the validity of psychophysiological measures to incumbent methods for assessing similar criteria, (c) test whether psychophysiological measures show either greater validity or clinically meaningful incremental validity, and (d) factor in fiscal costs as well as the utilities that the client attaches to different assessment outcomes. The statistical methods are now readily available, along with the interpretive models for integrating assessment results into client-centered decision making. These, combined with technology reducing the cost of psychophysiological measurement and improving ease of interpretation, poise the field for a rapid transformation of assessment practice, but only if we let go of old habits of research.

  2. Results from a psychometric assessment of a new tool for measuring evidence-based decision making in public health organizations.

    Stamatakis, Katherine A; Ferreira Hino, Adriano Akira; Allen, Peg; McQueen, Amy; Jacob, Rebekah R; Baker, Elizabeth A; Brownson, Ross C

    2017-02-01

    In order to better understand how to improve evidence-based decision making (EBDM) in state health departments, measurement tools are needed to evaluate changes in EBDM. The purpose of this study was to test the psychometric properties of a new measurement tool to assess EBDM in public health practice settings. A questionnaire was developed, pilot-tested and refined in an iterative process with the input of public health practitioners with the aim of identifying a set of specific measures representing different components of EBDM. Data were collected in a national survey of state health department chronic disease practitioners. The final dataset (n=879) for psychometric testing was comprised of 19 EBDM items that were first examined using exploratory factor analysis, and then confirmatory factor analysis. The final model from confirmatory factor analysis includes five latent factors representing components of EBDM: capacity for evaluation, expectations and incentives for EBDM, access to evidence and resources for EBDM, participatory decision making, and leadership support and commitment. This study addresses the need for empirically tested and theory-aligned measures that may be used to assess the extent to which EBDM is currently implemented, and further, to gauge the success of strategies to improve EBDM, in public health settings. This EBDM measurement tool may help identify needed supports for enhanced capacity and implementation of effective strategies. Copyright © 2016. Published by Elsevier Ltd.

  3. Flame Spectrophotometric Determination of Strontium in Water and Biological Material

    Joensson, G

    1964-10-15

    A flame spectrophotometric method has been developed for the determination of strontium in biological material and water samples. Strontium is determined in the presence of calcium at a wavelength of 4607 A. The intensity of the strontium emission from the sample is increased if n-butanol is added to a solution of the sample in water. With a 6 vol% solution of n-butanol in water, an optimum intensity of 3.5 times that obtained with pure water solution is obtained. Anions and alkali metals which might interfere with the flame spectrophotometric determination are separated from the sample by a simple ion exchange operation. The method allows determination of strontium in solutions down to 0.1{mu}g/ml. In this case the standard deviation is 3.1 % and with a strontium concentration of 1 {mu}g/ml the deviation is 0.9 %. This method has been used for the determination of strontium in samples of varying composition such as bone, meat and skin from fishes, samples of human bones, shell-fish, milk, and water, in which case Sr quantities of 5{mu}g were determined with an analytical error of less than 5 % and Sr{sub q}uantities greater than 10 {mu}g with an error of less than 3 %.

  4. Estimation of citicoline sodium in tablets by difference spectrophotometric method

    Sagar Suman Panda

    2013-01-01

    Full Text Available Aim: The present work deals with development and validation of a novel, precise, and accurate spectrophotometric method for the estimation of citicoline sodium (CTS in tablets. This spectrophotometric method is based on the principle that CTS shows two different forms that differs in the absorption spectra in basic and acidic medium. Materials and Methods: The present work was being carried out on Shimadzu 1800 Double Beam UV-visible spectrophotometer. Difference spectra were generated using 10 mm quartz cells over the range of 200-400 nm. Solvents used were 0.1 M NaOH and 0.1 M HCl. Results: The maxima and minima in the difference spectra of CTS were found to be 239 nm and 283 nm, respectively. Amplitude was calculated from the maxima and minima of spectrum. The drug follows linearity in the range of 1-50 μ/ml (R 2 = 0.999. The average % recovery from the tablet formulation was found to be 98.47%. The method was validated as per International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use: ICH Q2(R1 Validation of Analytical Procedures: Text and Methodology guidelines. Conclusion: This method is simple and inexpensive. Hence it can be applied for determination of the drug in pharmaceutical dosage forms.

  5. Flame Spectrophotometric Determination of Strontium in Water and Biological Material

    Joensson, G.

    1964-10-01

    A flame spectrophotometric method has been developed for the determination of strontium in biological material and water samples. Strontium is determined in the presence of calcium at a wavelength of 4607 A. The intensity of the strontium emission from the sample is increased if n-butanol is added to a solution of the sample in water. With a 6 vol% solution of n-butanol in water, an optimum intensity of 3.5 times that obtained with pure water solution is obtained. Anions and alkali metals which might interfere with the flame spectrophotometric determination are separated from the sample by a simple ion exchange operation. The method allows determination of strontium in solutions down to 0.1μg/ml. In this case the standard deviation is 3.1 % and with a strontium concentration of 1 μg/ml the deviation is 0.9 %. This method has been used for the determination of strontium in samples of varying composition such as bone, meat and skin from fishes, samples of human bones, shell-fish, milk, and water, in which case Sr quantities of 5μg were determined with an analytical error of less than 5 % and Sr q uantities greater than 10 μg with an error of less than 3 %

  6. Making Ultraviolet Spectro-Polarimetry Polarization Measurements with the MSFC Solar Ultraviolet Magnetograph Sounding Rocket

    West, Edward; Cirtain, Jonathan; Kobayashi, Ken; Davis, John; Gary, Allen

    2011-01-01

    This paper will describe the Marshall Space Flight Center's Solar Ultraviolet Magnetograph Investigation (SUMI) sounding rocket program. This paper will concentrate on SUMI's VUV optics, and discuss their spectral, spatial and polarization characteristics. While SUMI's first flight (7/30/2010) met all of its mission success criteria, there are several areas that will be improved for its second and third flights. This paper will emphasize the MgII linear polarization measurements and describe the changes that will be made to the sounding rocket and how those changes will improve the scientific data acquired by SUMI.

  7. Uncovering curvilinear relationships between conscientiousness and job performance: how theoretically appropriate measurement makes an empirical difference.

    Carter, Nathan T; Dalal, Dev K; Boyce, Anthony S; O'Connell, Matthew S; Kung, Mei-Chuan; Delgado, Kristin M

    2014-07-01

    The personality trait of conscientiousness has seen considerable attention from applied psychologists due to its efficacy for predicting job performance across performance dimensions and occupations. However, recent theoretical and empirical developments have questioned the assumption that more conscientiousness always results in better job performance, suggesting a curvilinear link between the 2. Despite these developments, the results of studies directly testing the idea have been mixed. Here, we propose this link has been obscured by another pervasive assumption known as the dominance model of measurement: that higher scores on traditional personality measures always indicate higher levels of conscientiousness. Recent research suggests dominance models show inferior fit to personality test scores as compared to ideal point models that allow for curvilinear relationships between traits and scores. Using data from 2 different samples of job incumbents, we show the rank-order changes that result from using an ideal point model expose a curvilinear link between conscientiousness and job performance 100% of the time, whereas results using dominance models show mixed results, similar to the current state of the literature. Finally, with an independent cross-validation sample, we show that selection based on predicted performance using ideal point scores results in more favorable objective hiring outcomes. Implications for practice and future research are discussed.

  8. Standard Reference Test Method for Making Potentiostatic and Potentiodynamic Anodic Polarization Measurements

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method covers an experimental procedure for checking experimental technique and instrumentation. If followed, this test method will provide repeatable potentiostatic and potentiodynamic anodic polarization measurements that will reproduce data determined by others at other times and in other laboratories provided all laboratories are testing reference samples from the same lot of Type 430 stainless steel. 1.2 Values stated in SI units are to be regarded as the standard. Inch-pound units given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. A definition of distance and method of making space-time measurements

    Brisson, D.W.

    1980-01-01

    The paper explores an extended definition of the absolute value of a complex number and thus a new definition of distance. This new definition, called the nabsolute value of a complex number, is (Z) where Z = (a or ia) + (b or ib), so that (Z) is equivalent to [α 2 + β 2 ]sup(1/2), and α = a or ia, β = b or ib. This is shown on a superimposed X,Y plot and iX,iY plot so that four dimensions are represented in a plane. The application of this scheme to space-time measurement is then identified with the Minkowski Plane which has identical properties with the complex plane, with this new interpretation of the absolute value of a complex number. (Auth.)

  10. Spectrophotometric Determination of Labetalol and Lercanidipine in Pure Form and in Pharmaceutical Preparations Using Ferric-1,10-Phenanthroline

    Abu El-Enin, M. A.; El-Wasseef, D. R.; El-Sherbiny, D. T.; El-Ashry, S. M.

    2009-01-01

    A simple and sensitive spectrophotometric method was developed for the determination of labetalol HCl (LBT) and lercanidipine HCl (LER) in pure form and in dosage forms. The method was based upon oxidation of the LBT and LER with Fe+3 and the estimation of the produced Fe+2 with 1,10-phenanthroline. The absorbance of the tris(1,10-phenanthroline) Fe+2 complex was measured at 510 nm. Reaction conditions were optimized to obtain colored complex of higher sensitivity and longer stability. The ab...

  11. AN APPLICATION OF FLOW INJECTION ANALYSIS WITH GAS DIFFUSION AND SPECTROPHOTOMETRIC DETECTION FOR THE MONITORING OF DISSOLVED SULPHIDE CONCENTRATION IN ENVIRONMENTAL SAMPLES

    Malwina Cykowska

    2014-10-01

    Full Text Available The monitoring of the concentration of sulphide is very important from the environment point of view because of high toxicity of hydrogen sulphide. What is more hydrogen sulphide is an important pollution indicator. In many cases the determination of sulphide is very difficult due to complicated matrix of some environmental samples, which causes that most analytical methods cannot be used. Flow injection analysis allows to avoid matrix problem what makes it suitable for a wide range of applications in analytical laboratories. In this paper determination of dissolved sulphide in environmental samples by gas-diffusion flow injection analysis with spectrophotometric detection was presented. Used gas-diffusion separation ensures the elimination of interferences caused by sample matrix and gives the ability of determination of sulphides in coloured and turbid samples. Studies to optimize the measurement conditions and to determine the value of the validation parameters (e.g. limit of detection, limit of quantification, precision, accuracy were carried out. Obtained results confirm the usefulness of the method for monitoring the concentration of dissolved sulphides in water and waste water. Full automation and work in a closed system greatly reduces time of analysis, minimizes consumption of sample and reagents and increases safety of analyst’s work.

  12. Spectrophotometric and spectrofluorimetric methods for the determination of saxagliptin and vildagliptin in bulk and pharmaceutical preparations

    Marwa S. Moneeb

    2013-12-01

    Full Text Available New simple and sensitive spectrophotometric and spectrofluorimetric methods have been developed and validated for the determination of saxagliptin (SAX and vildagliptin (VDG in bulk and pharmaceutical preparations. The spectrophotometric methods were based on derivatization of the investigated drugs with two reagents: 1,2-naphthoquinone-4-sulfonic acid sodium salt (NQS and 4-chloro-7-nitrobenzofurazan (NBD-Cl. For further increase in the sensitivity, the D1 spectra of the reactions products were also recorded. For NQS reaction, Beer’s law was obeyed over the ranges of 5–30 and 7–45 μg mL−1 for the absorbance readings; and 3–32 and 5–50 μg mL−1 for the derivative readings of SAX and VDG, respectively. For NBD-Cl reaction, Beer’s law was obeyed over the ranges of 3–20 and 4.5–35 μg mL−1 for the absorbance readings; and 1.5–25 and 2.5–40 μg mL−1 for the derivative readings of SAX and VDG, respectively. Spectrofluorimetric methods were developed based on the fact that the derivatized investigated drugs with NBD-Cl reagent are highly fluorescent products. The fluorescence concentration plots were linear over the ranges of 0.02–0.25 and 0.03–0.37 μg mL−1 for SAX and VDG, respectively. The fluorescence measurement enabled the detection of SAX and VDG at concentrations of about 3 and 7 ng mL−1, respectively. The proposed methods have been validated and successfully applied to the determination of the investigated drugs in their pharmaceutical preparations. The results obtained were statistically compared to those obtained from reference methods.

  13. Study of extraction-spectrophotometric micro-determination of boron with methylene blue and its application

    Zhu Daohong

    1990-08-01

    A sensitive extraction-spectrophotometric method for microdetermination of boron with methylene blue was investigated. The method was based on the extraction of a BF 4 - -methylene blue complex into dichloroethane. Boron was determined directly by measuring the absorbance at 658 nm. The calibration graph was linear over the range of 2.5 x 10 -9 to 8 x 10 -8 g/mL. The blank, mechanism of the reactions, interference of other ions and some optimum conditions of the method were studied in detail. The main source of the blank resulted from methylene blue and the complex of F - -methylene blue. In order to reduce the blank, the amounts of methylene blue, H 2 SO 4 and HF were used as less as possible. Only one to one complex BF 4 - -methylene blue was formed in the medium of H 2 SO 4 . About 90% of methylene blue and F - -methylene blue complex was removre with 5 ml of water and only a little amount of BF 4 -methylene blue complex was decomposed. The extraction-spectrophotometric method with methylene blue was first applied to the microdetermination of boron in sodium metal and UF 6 . The sample of sodium metal was taken and weighed in the glovebox filled with argon. Then sodium metal was oxidized, hydrolyzed, netralized and fluorizated with H 2 O, H 2 SO 4 and HF, respectively. The 0.5 ppm of boron in sodium metal was determined with a relative error about ±4%. This method can be applied to the determination of boron in sodium metal, sodium sulfate and sodium hydroxide at diffeent grades. The species of boron in the hydrolysate of UF 6 is BF 4 - anion, so the sample can be directly analyzed. Boron contents in the range of 0.1 to 0.5 ppm was determined with a relative error about ±3%. Six samples could be analysed in 2h

  14. Kinetic spectrophotometric method for the determination of perindopril erbumine in pure and commercial dosage forms

    Nafisur Rahman

    2017-02-01

    Full Text Available A kinetic spectrophotometric method has been developed for the determination of perindopril erbumine in pure and commercial dosage forms. The method is based on the reaction of drug with potassium permanganate in alkaline medium at room temperature (30 ± 1 °C. The reaction was followed spectrophotometrically by measuring the increase in absorbance with time at 603 nm and the initial rate, fixed time (at 8.0 min and equilibrium time (at 90.0 min methods were adopted for constructing the calibration graphs. All the calibration graphs are linear in the concentration range of 5.0–50.0 μg/ml. The limits of detection for initial rate, fixed time and equilibrium time methods were 0.752, 0.882 and 1.091 μg/ml, respectively. The activation parameters such as Ea, ΔH‡, ΔS‡ and ΔG‡ were also determined for the reaction and found to be 60.93 kJ/mol, 56.45 kJ/mol, 74.16 J/K mol and −6.53 kJ/mol, respectively. The variables were optimized and the proposed methods are validated as per ICH guidelines. The method has been further applied to the determination of perindopril erbumine in commercial dosage forms. The analytical results of the proposed methods when compared with those of the reference method show no significant difference in accuracy and precision and have acceptable bias.

  15. New potentiometric and spectrophotometric methods for the determination of dextromethorphan in pharmaceutical preparations.

    Elmosallamy, Mohamed A F; Amin, Alaa S

    2014-01-01

    New, simple and convenient potentiometric and spectrophotometric methods are described for the determination of dextromethorphan hydrobromide (DXM) in pharmaceutical preparations. The potentiometric technique is based on developing a potentiometric sensor incorporating the dextromethorphan tetrakis(p-chlorophenyl)borate ion-pair complex as an electroactive species in a plasticized PVC matrix membrane with o-nitophenyl octyl ether or dioctyl phthalate. The sensor shows a rapid near Nernstian response of over 1 × 10(-5) - 1 × 10(-2) mol L(-1) dextromethorphan in the pH range of 3.0 - 9.0. The detection limit is 2 × 10(-6) mol L(-1) DXM and the response time is instantaneous (2 s). The proposed spectrophotometric technique involves the reaction of DXM with eriochrom black T (EBT) to form an ion-associate complex. Solvent extraction is used to improve the selectivity of the method. The optimal extraction and reaction conditions have been studied, and the analytical characteristics of the method have been obtained. Linearity is obeyed in the range of 7.37 - 73.7 × 10(-5) mol L(-1) DXM, and the detection limit of the method is 1.29 × 10(-5) mol L(-1). The relative standard deviation (RSD) and relative error for six replicate measurements of 3.685 × 10(-4) mol L(-1) are 0.672 and 0.855%, respectively. The interference effect of some excepients has also been tested. The drug contents in pharmaceutical preparations were successfully determined by the proposed methods by applying the standard-addition technique.

  16. How do american students measure up? Making sense of international comparisons.

    Koretz, Daniel

    2009-01-01

    In response to frequent news media reports about how poorly American students fare compared with their peers abroad, Daniel Koretz takes a close look at what these comparisons say, and do not say, about the achievement of U.S. high school students. He stresses that the comparisons do not provide what many observers of education would like: unambiguous information about the effectiveness of American high schools compared with those in other nations. Koretz begins by describing the. two principal international student comparisons-the Trends in International Mathematics and Science Study (TIMSS) and the Program for International Student Assessment (PISA). Both assessments, he stresses, reflect the performance of students several years before they complete high school. PISA, which targets fifteen-year-old students, measures students' abilities to apply what they have learned in school to real-world problems. By contrast, TIMSS tests fourth and eighth graders. Unlike PISA, TIMSS follows the school curriculum closely. Because the findings of the two tests are sometimes inconsistent, Koretz stresses the importance of considering data from both sources. He cautions against comparing U.S. students with an "international average," which varies widely from survey to survey depending on which countries participate, and recommends instead comparing them with students in other nations that are similar to the United States or that are particularly high-achieving. Many observers, says Koretz, speculate that the lackluster average performance of American students in international comparisons arises because many, especially minority and low-income U.S. students, attend low-performing schools. But both TIMSS and PISA, he says, show that the performance of American students on the exams is not much more variable than that of students in countries that are socially more homogeneous or that have more equitable educational systems. Koretz emphasizes that the international comparisons

  17. Test-retest assessment of functional near-infrared spectroscopy to measure risk decision making in young adults

    Li, Lin; Lin, Zijing; Cazzell, Mary; Liu, Hanli

    2013-03-01

    Investigation of the reliability and reproducibility of the hemodynamic response is important for interpretation and understanding of the results of functional near-infrared spectroscopy (fNIRS). It measures optical signals absorbed by the brain tissue and reflects the neuronal activities indirectly. Here we described an fNIRS study measured in the prefrontal region (Brodman area 9, 10, part of 46)to examine the risk decision-making behavior in nine young adults. The Balloon Analog Risk Task (BART) is widely used to test the level of risk taking ability in the field of psychology. BART was a protocol utilized in this study to evoke a risk-taking environment with a gambling-like balloon game in each subject. Specifically, we recorded the brain oxygenated-hemoglobin (HbO) and deoxygenated-hemoglobin (HHb) changes during the two repeated measurements within a time interval of 3 weeks. The results demonstrate that the changes in HbO2 amplitudes have high reliability at the group level, and that the spatial patterns of the tomographic images have high reproducibility in size and a moderate degree of overlap. Overall, this study confirms that the hemodynamic response to risk decision-making (i.e., BART) seen by fNIRS is highly reliable and reproducible.

  18. SPECTROPHOTOMETRIC STUDIES OF SANGUINARINE-Β-CYCLODEXTRIN COMPLEX FORMATION

    Veaceslav Boldescu

    2008-06-01

    Full Text Available The main aim of this study was to investigate the influence of pH and the presence of hydrophilic polymer polyvinylpyrrolidone on the formation of sanguinarine-β-cyclodextrin (SANG-β-CD inclusion complex. Spectrophotometric studies of the SANG-β-CD systems in the presence and without 0.1 % PVP at the pH 5.0 did not show any evidence of the complex formation. However, the same systems showed several obvious evidences at the pH 8.0: the hyperchromic and the hypochromic effects and the presence of the isosbestic point in the region of 200 – 210 nm. The association constants calculated by three linear methods: Benesi-Hildebrand, Scott and Scatchard, were two times higher for the systems with addition of 0.1% PVP than for the systems without it.

  19. An efficient absorbing system for spectrophotometric determination of nitrogen dioxide

    Kaveeshwar, Rachana; Amlathe, Sulbha; Gupta, V. K.

    A simple and sensitive spectrophotometric method for determination of atmospheric nitrogen dioxide using o-nitroaniline as an efficient absorbing, as well as diazotizing, reagent is described. o-Nitroaniline present in the absorbing medium is diazotized by the absorbed nitrite ion to form diazonium compound. This is later coupled with 1-amino-2-naphthalene sulphonic acid (ANSA) in acidic medium to give red-violet-coloured dye,having λmax = 545 nm. The isoamyl extract of the red azo dye has λmax = 530 nm. The proposed reagents has ≈ 100% collection efficiency and the stoichiometric ratio of NO 2:NO 2- is 0.74. The other important analytical parameters have been investigated. By employing solvent extraction the sensitivity of the reaction was increased and up to 0.03 mg m -3 nitrogen dioxide could be estimated.

  20. Spectrophotometric determination of triclosan in personal care products

    Lu, Huihui; Ma, Hongbing; Tao, Guanhong

    2009-09-01

    A spectrophotometric method for the determination of triclosan in personal care products was proposed. It was based on the reaction of sodium nitrite with p-sulfanilic acid in an acidic medium to form diazonium ion, with which triclosan further formed an azo compound in an alkaline medium. The resulting yellow colored product has a maximum absorption at 452 nm. A good linear relationship ( r = 0.9999) was obtained in the range of 0-30 mg L -1 triclosan. A detection limit of 0.079 g L -1 was achieved and the relative standard deviation was 0.24% ( n = 11) at 14 mg L -1 triclosan. The proposed method has been applied to the analyses of triclosan in several personal care products and the results were in good agreement with those obtained by high-performance liquid chromatography.

  1. Spectrophotometric determination of the first hydrolysis constant of praseodymium (III)

    Gonzalez M, R.; Lopez G, H. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Rojas H, A., E-mail: hilario.lopez@inin.gob.m [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Departamento de Quimica, Av. San Rafael Atlixco No. 186, Col. Vicentina, 09340 Mexico D. F. (Mexico)

    2010-07-01

    The behavior of the trivalent ion praseodymium in 2 M of NaCl at 303 K and in CO{sub 2} free conditions, was studied. Spectrophotometric titrations of the soluble species were used, in order to obtain the value of the first hydrolysis constant of Pr(III). The data obtained were treated with both the program Squad and by a graphic method, respectively. The result obtained using Squad was log*{beta}{sub 1}= -8.94 {+-} 0.03, while it was log*{beta}{sub 1}= -8.77 {+-} 0.03, when calculated graphically. These results are similar to the value obtained previously with the potentiometric method. (Author)

  2. Spectrophotometric intracutaneous analysis for differential diagnosis of pigmented skin lesions

    Е. V. Filonenko

    2013-01-01

    Full Text Available The non-invasive diagnosis of pigmented skin lesions by spectrophotometric intracutaneous analysis (SIA-scopy using device for dermatoscopy (SIAscope V by Astron Clinica, Ltd was approved in P.A.Herzen Moscow Cancer Research Institute. The method is based on analysis of light interaction with wavelength of 440–960 nm anf human skin, which is recorded by change of image on scan. The comparative analysis of SIA-scopy and histological data in 327 pigmented skin lesions in 147 patients showed, that SIA had high diagnostic efficiency for cutaneous melanoma: the sensitivity was 96%, specifity – 94%, diagnostic accuracy – 94%. For study of malignant potential of pigmented lesions by SIA-scopy the most informative capacity was obtained for assessment of melanin in papillary dermis, status of blood vessels and collagen fibres (SIA-scans 3, 4, 5.

  3. Extractive Spectrophotometric Methods for the Determination of Etoricoxib in Tablets

    Kamal Shah

    2009-01-01

    Full Text Available Two simple, rapid, sensitive, precise and economic spectrophotometric methods have been developed for the estimation of etoricoxib in tablet formulation. During the course of study, it was observed that acidic solution of the drug formed colored ion-association complexes with Bromocresol Green (BCG and Bromocresol Purple (BCP which were soluble in chloroform. This property of the drug was followed for the development of colorimetric methods for analysis of drug. The complex of etoricoxib with BCG and BCP showed λmax at 416 nm and 408 nm respectively. These methods were validated statistically. Recovery studies gave satisfactory results indicating that none of common additives and excipients interfere the assay method. The proposed methods are found to be simple, accurate and reproducible that was successfully applied for the analysis of tablet formulation.

  4. Spectrophotometric titration of sulfates in the presence of zirconium

    Kuznetsov, V.V.; Kotova, S.S.; Molokanova, L.G.; Chekmarev, A.M.; Yagodin, G.A.

    1978-01-01

    The procedure has been proposed for express determination of sulphate ions in the presence of zirconium by spectrophotometric titration with the use of barium chloride and nitrochromazo as an indicator. The procedure is based on bonding zirconium into a more stable complex with EDTA (ethylenediaminotetraacetic acid). The presence of excess of EDTA and zirconium (4) complexonate in the solution being titrated does not affect the titration curve shape and the character of break on the curve in the equivalence point. A complete demasking of SO 4 2- is observed in the case of 1O-fold excess of EDTA with respect to zirconium (4). Statistic evaluation of the method has shown that the results of titration can be distorted by chance errors only

  5. Extractive spectrophotometric determination of uranium with malachite green

    Dubey, S C; Nadkarni, M N [Bhabha Atomic Research Centre, Bombay (India). Fuel Reprocessing Div.

    1977-04-01

    A sensitive spectrophotometric method based on the extraction of a uranium-benzoate-Malachite Green complex by chlorobenzene is described. The absorption maximum is at 635 nm and the molar absorptivity is 8.3 x 10/sup 4/1. mole /sup -1/ cm/sup -1/. A preliminary separation of uranium by extraction with methyl isobutyl ketone from acid-deficient aluminium nitrate solution is used to avoid interferences. An aliquot of the extract in then diluted with chlorobenzene and shaken with benzoate buffer containing Malachite Green (MG). The method has been applied for the determination of uranium in a synthetic leach solution. The complex extracted is probably (U0/sub 2/(C/sub 6/H/sub 5/C00/sub 3//sup -/)(MG/sup +/).

  6. Extractive spectrophotometric determination of uranium with malachite green

    Dubey, S.C.; Nadkarni, M.N.

    1977-01-01

    A sensitive spectrophotometric method based on the extraction of a uranium-benzoate-Malachite Green complex by chlorobenzene is described. The absorption maximum is at 635 nm and the molar absorptivity is 8.3 x 10 4 1. mole -1 cm -1 . A preliminary separation of uranium by extraction with methyl isobutyl ketone from acid-deficient aluminium nitrate solution is used to avoid interferences. An aliquot of the extract in then diluted with chlorobenzene and shaken with benzoate buffer containing Malachite Green (MG). The method has been applied for the determination of uranium in a synthetic leach solution. The complex extracted is probably [U0 2 (C 6 H 5 C00 3 - ][MG + ]. (author)

  7. Spectrophotometric determination of La (III) with sulphamethoxazole based hydroxy triazene

    Manwani, Sapana; Chauhan, R.S.; Goswami, A.K.

    2015-01-01

    In the present study, 3-hydroxy-3-p-chlorophenyll-1-(4-amino-N-(5-methyl-1,2-oxazole-3- yl) benzenesulphonamide-methane) triazene has been synthesized by coupling of hydroxylamine obtained by reduction of nitro compound with diazonium salt obtained from sulphamethoxazole taking hydroxylamine in excess at temperature between 0-5°C. Chemical structure of the synthesized compound was confirmed by IR, 1 H NMR, MASS and by elemental analysis. The complex of the reagent with La (III) has been studied. 3-hydroxy-3-p-chlorophenyll-1-(4-amino-N-(5-methyl-1,2-oxazole-3-yl) benzenesulphonamide-methane) triazene has been used for spectrophotometric determination of lanthanum (III) at 392 nm, keeping the pH between 8.5 to 8.9

  8. Spectrophotometric investigation of vanadium(4) complexing with monoamine complexones

    Merkulov, D.A.; Kornev, V.I.

    1998-01-01

    Interaction of vanadium(4) with iminodiacetic (H 2 Ida) and methyliminodiacetic (H 2 Mida) acids by μ = 0.1 (NaClO 4 ) and t = 20±2 deg C is studied through the spectrophotometric method. It is established that the process of complex formation in quasi-binary systems due to competitive effect of hydroxide ions depends to a large degree on the ligands concentration and properties. The VOIda, VO(OH)Ida - , VOMida, VO(OH)Mida - complexes are identified. The stability constants logarithms of these complexes are equal correspondingly to 9.81±0.02, 18.19±0.03, 10.15±0.03, 18.34±0.02. The results of the study on the VO 2+ -HIda and VO 2+ -H 2 Mida systems agree well with the regularities, identified by the study on the vanadium(4) complex formation with other complexones of the iminodiacetate series

  9. Determination of lisinopril in pharmaceuticals by a kinetic spectrophotometric method

    Čakar Mira

    2012-01-01

    Full Text Available A kinetic spectrophotometric method for determination of lisinopril in pharmaceuticals has been developed. The method is based on activator action of lisinopril on Cu(II ions catalysing the oxidation of nile blue A with hydrogen peroxide in borate buffer (pH 9.3. A decrease of the absorbance was recorded at 635 nm for 5 min at 25°C. The linearity was established applying the tangent method within the concentration range of lisinopril from 0.8-6.4 μg mL-1, the detection and quantification limits being 0.158 μg mL-1 and 0.480 μg mL-1, respectively. The method has been successfully applied in three brands of tablets containing lisinopril alone or in combination with hydrochlorothiazide.

  10. Spectrophotometric study of lanthanoid complexes with antipyrine and salicylic acid

    Tishchenko, M A; Gerasimenko, G I; Poluehktov, N S [AN Ukrainskoj SSR, Odessa. Fiziko-Khimicheskij Inst.

    1981-01-01

    The extraction-spectrophotometric method has been used to study lanthanoid ion complexing (Pr, Nd, Ho and Er) with antipyrine (Ant) and salicylic acid (Sal). The component relationship in different-ligand compounds Ln:Ant:Sal=2:3:6 and solvate number equal to 5 are determined; molar extinction coefficients of binary and different-ligand compounds are calculated. Oscillator strengths of absorption bands corresponding to supersensitive transitions of neodymium, holmium, erbium and some most intensive praseodymium bands are calculated. The study of IR spectra of investigated compounds allows to conclude on formation of coordination bonds of the central atom with the antipyrine molecule through the oxygen of the carbonyl group as well as on carboxyl group hydrogen substitution for metal and formation of coordination bond with OH group in salicylic acid molecules.

  11. Spectrophotometric study of lanthanoid complexes with antipyrine and salicylic acid

    Tishchenko, M.A.; Gerasimenko, G.I.; Poluehktov, N.S.

    1981-01-01

    The extraction-spectrophotometric method has been used to study lanthanoid ion complexing (Pr, Nd, Ho and Er) with antipyrine (Ant) and salicylic acid (Sal). The component relationship in different-ligand compounds Ln:Aut:Sal=2:3:6 and solvate number equal to 5 are determined; molar extinction coefficients of binary and different-ligand compounds are calculated. Oscillator strengths of absorption bands corresponding to supersensitive transitions of neodymium, holmium, erbium and some most intensive praseodymium bands are calculated. The study of IR spectra of investigated compounds allows to conclude on formation of coordination bonds of the central atom with the antipyrine molecule through the oxygen of the carbonyl group as well as on carboxyl group hydrogen substitution for metal and formation of coordination bond with OH group in salicylic acid molecules [ru

  12. Spectrophotometric determination of catecholamine using vanadium and eriochrome cyanine r

    Nagaraja, Padmarajaiah; Shrestha, Ashwinee Kumar; Shivakumar, Anantharaman; Al-Tayar, Naef Ghallab Saeed; Gowda, Avinask K.

    2011-01-01

    highly sensitive spectrophotometric method for the analysis of catecholamine drugs; L-dopa and methyldopa, is described. The analysis is based on the reaction of drug molecules with vanadium (V) which is reduced to vanadium (IV) and form complex with eriochrome cyanine R to give products having maximum absorbance (λ max ) at 565 nm. Beer's law is obeyed in the range 0.028-0.84 and 0.099-0.996 μg mL -1 for L-dopa and methyldopa, respectively. The statistical analysis as well as comparison with reported methods demonstrated high precision and accuracy of the proposed method. The method was successfully applied in the analysis of pharmaceutical preparations. (author)

  13. Determination of dissolved inorganic species of iodine by spectrophotometric titration

    Pesavento, Maria; Profumo, Antonella; Biesuz, Raffaela

    1987-09-01

    A method for determining iodate and iodine (+1) in aqueous solutions is proposed. The assay is similar to a previously described method for the determination of iodide and iodine (O), which were titrated with standard iodate in hydrochloric acid solution. A sample solution made 0.5-1.5 M in hydrochloric acid is titrated with a standard iodide solution and monitored spectrophotometrically at 230 nm. The species involved have strong absorbances that are well differentiated at this wavelength. By combining the two titrations it is possible to resolve any mixture of species of iodine in different oxidation states. The precision of the method (standard deviation) is the same both when determining a single species (IO/sub 3/-,I+,1/sub 2/ or I-) and a mixture, and is equal to 2 x 10/sup -7/ M. Chloride and bromide, even at very high concentrations, do not interfere.

  14. Determination of dissolved inorganic species of iodine by spectrophotometric titration

    Pesavento, Maria; Profumo, Antonella

    1987-01-01

    A method for determining iodate and iodine (+1) in aqueous solutions is proposed. The assay is similar to a previously described method for the determination of iodide and iodine (O), which were titrated with standard iodate in hydrochloric acid solution. A sample solution made 0.5-1.5 M in hydrochloric acid is titrated with a standard iodide solution and monitored spectrophotometrically at 230 nm. The species involved have strong absorbances that are well differentiated at this wavelength. By combining the two titrations it is possible to resolve any mixture of species of iodine in different oxidation states. The precision of the method (standard deviation) is the same both when determining a single species (IO 3 -,I+,1 2 or I-) and a mixture, and is equal to 2 x 10 -7 M. Chloride and bromide, even at very high concentrations, do not interfere. (author)

  15. Spectrophotometric Methods for the Assay of Fluvoxamine Using Chromogenic Reagents

    V. Annapurna

    2010-01-01

    Full Text Available Simple, accurate and reproducible UV-Visible spectrophotometric methods were established for the assay of FXA based on the oxidative coupling and condensation reactions. Condensation and coupling of the FXA with Ninhydrin-Ascorbic acid is proposed in method A. Method B includes complexation of FXA with cobalt thiocyanate. The ligating property of FXA with sodium nitro prusside is incorporated in method C. The optical characteristics such as Beers law limits, molar absorptivity and Sandell’s sensitivity for the methods (A-C are given. Regression analysis using the method of least squares was made to evaluate the slope(b, intercept(a and correlation coefficient (r and standard error of estimation (Se for each system. Determination of FXA in bulk form and in pharmaceutical formulations were also incorporated.

  16. Development and Validation of UV-Visible Spectrophotometric Methods for Simultaneous Estimation of Thiocolchicoside and Dexketoprofen in Bulk and Tablet Dosage Form

    M. T. Harde; S. B. Jadhav; D. L. Dharam; P. D. Chaudhari

    2012-01-01

    Development and validation of two simple, accurate, precise and economical UV Spectrophotometric methods for simultaneous estimation of Thiocolchicoside and Dexketoprofen in bulk and in tablet dosage form. The methods employed were Method-1 Absorbance correction method and Method-2 First order derivative spectroscopic method. In method-1 Absorbance is measured at two wavelengths 370nm at which Dexketoprofen has no absorbance and 255nm at which both the drug have considerable absorbance. In me...

  17. Spectrophotometric and computerized evaluation of tooth bleaching employing 10 different home-bleaching procedures: In-vitro study

    Peskersoy, Cem; Tetik, Ayhan; Ozturk, Veli Ozgen; Gokay, Necmi

    2014-01-01

    Objective: The aim of this in-vitro study was to evaluate the efficacy of bleaching products, determine the applicability and validation of the measurement methods. Materials and Methods: Freshly extracted 110 human incisor teeth were stained with whole blood and hemolysate solution prior to the application of 10 different home-bleaching products. Spectrophotometric measurements of the tooth shades were performed for each specimen before and after bleaching at the 1st, 3rd, 7th, and 14 days. Differences in lightness (Δl), chroma (Δc), hue (Δh) values and shade changes were measured to evaluate process. Computerized digital imaging analyses to determine the color changes were performed with Photoshop CS4 software (Adobe, San Jose, CA, USA). Statistical analyses were performed with analysis of variance, Scheffe and Tukey tests. Results: In all of the test groups regardless of the material used, a significant increase in lightness and hue, and decrease of chroma were observed, as compared to the control group. After recommended bleaching applications, Δl and Δh values respectively increased in group Zaris White and Brite (ZWB) and group Pola Night and Δc values showed significant decrease in groups ZWB and Rembrandt REM3 (P bleaching systems showed slower but almost permanent bleaching effect likewise office-based methods. Both software and spectrophotometric analyses have advantages such as evaluating the results objectively and numerically, also treatment outcomes could be preserved. PMID:25512738

  18. Spectrophotometric and spectrofluorimetric methods for determination of certain biologically active phenolic drugs in their bulk powders and different pharmaceutical formulations

    Omar, Mahmoud A.; Badr El-Din, Kalid M.; Salem, Hesham; Abdelmageed, Osama H.

    2018-03-01

    Two simple and sensitive spectrophotometric and spectrofluorimetric methods for the determination of terbutaline sulfate, fenoterol hydrobromide, etilefrine hydrochloride, isoxsuprine hydrochloride, ethamsylate, doxycycline hyclate have been developed. Both methods were based on the oxidation of the cited drugs with cerium (IV) in acid medium. The spectrophotometric method was based on measurement of the absorbance difference (ΔA), which represents the excess cerium (IV), at 317 nm for each drug. On the other hand, the spectrofluorimetric method was based on measurement of the fluorescent of the produced cerium (III) at emission wavelength 354 nm (λexcitation = 255 nm) for the concentrations studied for each drug. For both methods, the variables affecting the reactions were carefully investigated and the conditions were optimized. Linear relationships were found between either ΔA or the fluorescent of the produced cerium (III) values and the concentration of the studied drugs in a general concentration range of 2.0-24.0 μg mL- 1, 20.0-24.0 ng mL- 1 with good correlation coefficients in the following range 0.9990-0.9999, 0.9990-0.9993 for spectrophotometric and spectrofluorimetric methods respectively. The limits of detection and quantitation of spectrophotometric method were found in general concentration range 0.190-0.787 and 0.634-2.624 μg mL- 1respectively. For spectrofluorimetric method, the limits of detection and quantitation were found in general concentration range 4.77-9.52 and 15.91-31.74 ng mL- 1 respectively. The stoichiometry of the reaction was determined, and the reactions pathways were postulated. The analytical performance of the methods, in terms of accuracy and precision, were statistically validated and the results obtained were satisfactory. The methods have been successfully applied to the determination of the cited drugs in their commercial pharmaceutical formulations. Statistical comparison of the results with the reference methods

  19. Sensitive inexpensive spectrophotometric and spectrofluorimetric analysis of ezogabine, levetiracetam and topiramate in tablet formulations using Hantzsch condensation reaction

    Ibrahim, F. A.; El-Yazbi, A. F.; Wagih, M. M.; Barary, M. A.

    2017-09-01

    Two highly sensitive, simple and selective spectrophotometric and spectrofluorimetric assays have been investigated for the analysis of ezogabine, levetiracetam and topiramate in their pure and in pharmaceutical dosage forms. The suggested methods depend on the condensation of the primary amino-groups in the three drugs with acetylacetone and formaldehyde according to Hantzsch reaction yielding highly fluorescent yellow colored dihydropyridine derivatives. The reaction products of ezogabine, levetiracetam and topiramate were measured spectrophotometrically at 418, 390 and 380 nm or spectrofluorimetrically at λem/ex of 495/425 nm, 490/415 nm and 488/410 nm, respectively. Various experimental conditions have been carefully studied to maximize the reaction yield. At the optimum reaction conditions, the calibration curves were rectilinear over the concentration ranges of 8-25, 60-180 and 80-200 μg/mL spectrophotometrically and 0.02-0.2, 0.2-1.2 and 0.2-1.5 μg/mL spectrofluorimetrically for ezogabine, levetiracetam and topiramate, respectively with good correlation coefficients. The suggested methods were applied successfully for the analysis of ezogabine, levetiracetam and topiramate in their commercial tablets with high percentage recoveries and negligible interference from various excipients in pharmaceutical dosage forms. The results were statistically analyzed and showed the absence of any significant difference between both developed and published methods. The procedures were validated and evaluated by the ICH guidelines revealing good reproducibility and accuracy. Therefore, the two proposed methods may be considered of high interest for practical and reliable analysis of ezogabine, levetiracetam and topiramate in pharmaceutical dosage forms.

  20. Sensitive spectrophotometric assay of simvastatin in pharmaceuticals using permanganate

    Kalsang Tharpa

    2010-03-01

    Full Text Available Two simple, sensitive, selective and inexpensive spectrophotometric methods are described for the determination of simvastatin (SMT in bulk drug and in tablets using permanganate as the oxidimetric reagent. In method A, SMT is treated with a measured excess of permanganate in acetic acid medium and the unreacted oxidant is measured at 550 nm, whereas in method B the reaction is carried out in alkaline medium and the resulting manganate is measured at 610 nm. In method A, the amount of permanganate reacted corresponds to the SMT content and the absorbance is found to decrease linearly with the concentration; and in method B, the absorbance increases with concentration. The working conditions of assays were optimized, and the methods were validated according to the current ICH guidelines. Under optimum conditions, SMT could be assayed in the concentration ranges, 1.47 - 17.67x10-5 and 2.27 - 27.18 x10-6 mol/L by method A and method B, respectively. The calculated molar absorptivities are 3.2 x 10³ and 2.5 x 10(4 L/mol/cm for method A and method B, respectively with corresponding Sandell sensitivity values of 0.0387 and 0.0178 μg/cm². The limits of detection (LOD and quantification (LOQ have also been reported. Accuracy and precision for the assay were determined by calculating the intra-day and inter-day at three concentrations; the intra-day RSD was Dois métodos espectrofotométricos simples, sensíveis, seletivos e baratos são descritos para a determinação de sinvastatina (SMT a granel e em comprimidos, utilizando permanganato como reagente oxidimétrico. No método A, a SMT é tratada com excesso conhecido de permanganato em meio de ácido acético e o oxidante que não reage é medido a 550 nm, enquanto no método B, a reação é efetuada em meio alcalino e o manganato resultante é medido a 610 nm. No método A, a quantidade de permanganato que reage corresponde ao conteúdo de SMT e a absorbância diminui linearmente com o aumento da

  1. Making Acquisition Measurable

    2011-04-30

    Corporation. All rights reserved End Users Administrator/ Maintainer (A/M) Subject Matter Expert ( SME ) Trainer/ Instructor Manager, Evaluator, Supervisor... CMMI ) - Acquisition (AQ) © 2011 The MITRE Corporation. All rights reserved 13 CMMI -Development Incremental iterative development (planning & execution...objectives Constructing games highlighting particular aspects of proposed CCOD® acquisition, and conducting exercises with Subject Matter Experts ( SMEs

  2. Acceptability criteria for linear dependence in validating UV-spectrophotometric methods of quantitative determination in forensic and toxicological analysis

    L. Yu. Klimenko

    2014-08-01

    dictated by the primary orientation of all studied international guidances on the work exactly by this method. The next criteria and the order of acceptability estimation of linearity for UV-spectrophotometric methods of quantitative determination analyses in biological fluids used in forensic and toxicological analysis have been offered: acceptability estimation of linear dependence parameters is carried out in two stages – for the lines obtained using model solutions (without matrix and calibration samples respectively; two approaches has been suggested for parameters estimation of linear dependence obtained using model solutions; they are based on: 1 assumption of equality of the uncertainty related to the procedure of sample preparation of calibration standards, and the uncertainty of the calibration curve plotted by model solutions; 2 assumption of insignificance of the uncertainty of the calibration curve plotted by model solutions; for both approaches the acceptability criteria have been offered for residual standard deviation and correlation coefficient ; for estimation of parameters of linear dependence obtained using calibration samples it has been suggested to proceed from assumption of equality of the calibration uncertainty and the uncertainty of measuring the absorbance and sample preparation of the sample to be analysed; within this approach the acceptability criteria have been offered for residual standard deviation RSD0 and correlation coefficient Rс; the parameters of within-run (within-day and between-run (between-day linearity should satisfy these criteria. Conclusion. The criteria and order of acceptability estimation of linearity for UV-spectrophotometric methods of quantitative determination analyses in biological fluids used in forensic and toxicological analysis have been formed. Offered approaches have been tested by example of UV-spectrophotometric method of doxylamine quantitative determination in blood.

  3. Spectrophotometric method for the determination of thorium in UO2 pellets

    Acosta L, E.

    1995-04-01

    This report presents a procedure with the description of the spectrophotometric method for the determination of the thorium element in uranium products including powders and pellets of uranium dioxide. Quantities can be determined starting from 1 ppm. (Author)

  4. Polarographic, spectrophotometric and coulometric studies of MoO=4 in H2SO4

    Tokoro, R.; Bertotti, M.

    1990-01-01

    This study characterizes the polarographic process of Mo O sup(=) sub(4) in H sub(2)SO sub(4) medium, determining which species is responsible by catalytic cycle. Spectrophotometric and coulometric studies are also described. (author)

  5. Spectrophotometric reading of EUCAST antifungal susceptibility testing of Aspergillus fumigatus

    Meletiadis, J.; Leth Mortensen, K.; Verweij, P. E.

    2017-01-01

    with spectrophotometrically determined MICs and essential (±1 twofold dilution) and categorical (susceptible/intermediate/resistant or wild-type/non-wild-type) agreement was calculated. Spectrophotometric data were analysed with regression analysis using the Emax model, and the effective concentration corresponding to 5% (EC......5) was estimated. Results Using the 5% cut-off, high essential (92%–97%) and categorical (93%–99%) agreement (

  6. SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF MONTELUKAST SODIUM AND BAMBUTEROL HYDROCHLORIDE IN TABLETS

    Patel Satish A; Patel Dhara J; Patel Natavarlal J.

    2011-01-01

    The present manuscript describe simple, sensitive, rapid, accurate, precise and economical first derivative spectrophotometric method for the simultaneous determination of montelukast sodium and bambuterol hydrochloride in combined tablet dosage form. The derivative spectrophotometric method was based on the determination of both the drugs at their respective zero crossing point (ZCP). The first order derivative spectra was obtained in chloroform and the determinations were made at 241 nm (ZC...

  7. Titrimetric and Spectrophotometric Determination of Metaprolol tartrate in Pharmaceuticals Using N-Bromosuccinimide

    K. Basavaiah; B. C. Somashekar

    2007-01-01

    One titrimetric and two spectrophotometric methods are presented for the assay of metaprolol tartrate (MPT) in bulk drug and in tablets. The methods employ N-bromosuccinimide (NBS) as the oxidimetric reagent and two dyes, methyl orange and indigo carmine as spectrophotometric reagents. In titrimetry, an acidified solution of MPT is treated with a known excess amount of NBS and after a definite time, the unreacted oxidant is determined by iodometric back titration. Spectrophotometry involve...

  8. Low relative error in consumer-grade GPS units make them ideal for measuring small-scale animal movement patterns

    Greg A. Breed

    2015-08-01

    Full Text Available Consumer-grade GPS units are a staple of modern field ecology, but the relatively large error radii reported by manufacturers (up to 10 m ostensibly precludes their utility in measuring fine-scale movement of small animals such as insects. Here we demonstrate that for data collected at fine spatio-temporal scales, these devices can produce exceptionally accurate data on step-length and movement patterns of small animals. With an understanding of the properties of GPS error and how it arises, it is possible, using a simple field protocol, to use consumer grade GPS units to collect step-length data for the movement of small animals that introduces a median error as small as 11 cm. These small error rates were measured in controlled observations of real butterfly movement. Similar conclusions were reached using a ground-truth test track prepared with a field tape and compass and subsequently measured 20 times using the same methodology as the butterfly tracking. Median error in the ground-truth track was slightly higher than the field data, mostly between 20 and 30 cm, but even for the smallest ground-truth step (70 cm, this is still a signal-to-noise ratio of 3:1, and for steps of 3 m or more, the ratio is greater than 10:1. Such small errors relative to the movements being measured make these inexpensive units useful for measuring insect and other small animal movements on small to intermediate scales with budgets orders of magnitude lower than survey-grade units used in past studies. As an additional advantage, these units are simpler to operate, and insect or other small animal trackways can be collected more quickly than either survey-grade units or more traditional ruler/gird approaches.

  9. [A multi-measure analysis of the similarity, attraction, and compromise effects in multi-attribute decision making].

    Tsuzuki, Takashi; Matsui, Hiroshi; Kikuchi, Manabu

    2012-12-01

    In multi-attribute decision making, the similarity, attraction, and compromise effects warrant specific investigation as they cause violations of principles in rational choice. In order to investigate these three effects simultaneously, we assigned 145 undergraduates to three context effect conditions. We requested them to solve the same 20 hypothetical purchase problems, each of which had three alternatives described along two attributes. We measured their choices, confidence ratings, and response times. We found that manipulating the third alternative had significant context effects for choice proportions and confidence ratings in all three conditions. Furthermore, the attraction effect was the most prominent with regard to choice proportions. In the compromise effect condition, although the choice proportion of the third alternative was high, the confidence rating was low and the response time was long. These results indicate that the relationship between choice proportions and confidence ratings requires further theoretical investigation. They also suggest that a combination of experimental and modeling studies is imperative to reveal the mechanisms underlying the context effects in multi-attribute, multi-alternative decision making.

  10. PRISM, a Novel Visual Metaphor Measuring Personally Salient Appraisals, Attitudes and Decision-Making: Qualitative Evidence Synthesis.

    Tom Sensky

    Full Text Available PRISM (the Pictorial Representation of Illness and Self Measure is a novel, simple visual instrument. Its utility was initially discovered serendipitously, but has been validated as a quantitative measure of suffering. Recently, new applications for different purposes, even in non-health settings, have encouraged further exploration of how PRISM works, and how it might be applied. This review will summarise the results to date from applications of PRISM and propose a generic conceptualisation of how PRISM works which is consistent with all these applications.A systematic review, in the form of a qualitative evidence synthesis, was carried out of all available published data on PRISM.Fifty-two publications were identified, with a total of 8254 participants. Facilitated by simple instructions, PRISM has been used with patient groups in a variety of settings and cultures. As a measure of suffering, PRISM has, with few exceptions, behaved as expected according to Eric Cassell's seminal conceptualisation of suffering. PRISM has also been used to assess beliefs about or attitudes to stressful working conditions, interpersonal relations, alcohol consumption, and suicide, amongst others.This review supports PRISM behaving as a visual metaphor of the relationship of objects (eg 'my illness' to a subject (eg 'myself' in a defined context (eg 'my life at the moment'. As a visual metaphor, it is quick to complete and yields personally salient information. PRISM is likely to have wide applications in assessing beliefs, attitudes, and decision-making, because of its properties, and because it yields both quantitative and qualitative data. In medicine, it can serve as a generic patient-reported outcome measure. It can serve as a tool for representational guidance, can be applied to developing strategies visually, and is likely to have applications in coaching, psychological assessment and therapeutic interventions.

  11. Spectrophotometric determination of nitrite based on its catalytic effect on the reaction of nuclear fast red and potassium bromate

    HASSAN ZAVVAR MOUSAVI

    2009-08-01

    Full Text Available A highly selective and sensitive catalytic spectrophotometric method was developed for the determination of nitrite in water samples. The method is based on its catalytic effect on the nuclear fast red–potassium bromate redox reaction in acidic medium. The reaction was followed spectrophotometrically by measuring the change in the absorbance at 518 nm of nuclear fast red 5 min after initiation of the reaction. In this study, the experimental parameters were optimized and the effects of other cations and anions on the determination of nitrite were examined. The calibration graph was linear in the range 2.0–45 µg mL-1 of nitrite. The relative standard deviations for the determination of 15 and 30 µg mL-1 of nitrite were 3.1 and 1.75 %, respectively (n = 8. The detection limit calculated from three times the standard deviation of the blank 3Sb was 0.7 µg mL-1. The method was successfully applied to the determination of nitrite in spiked tap, natural and wastewater samples.

  12. Rapid and direct spectrophotometric method for kinetics studies and routine assay of peroxidase based on aniline diazo substrates.

    Mirazizi, Fatemeh; Bahrami, Azita; Haghbeen, Kamahldin; Shahbani Zahiri, Hossein; Bakavoli, Mehdi; Legge, Raymond L

    2016-12-01

    Peroxidases are ubiquitous enzymes that play an important role in living organisms. Current spectrophotometrically based peroxidase assay methods are based on the production of chromophoric substances at the end of the enzymatic reaction. The ambiguity regarding the formation and identity of the final chromophoric product and its possible reactions with other molecules have raised concerns about the accuracy of these methods. This can be of serious concern in inhibition studies. A novel spectrophotometric assay for peroxidase, based on direct measurement of a soluble aniline diazo substrate, is introduced. In addition to the routine assays, this method can be used in comprehensive kinetics studies. 4-[(4-Sulfophenyl)azo]aniline (λmax = 390 nm, ɛ = 32 880 M(-1) cm(-1) at pH 4.5 to 9) was introduced for routine assay of peroxidase. This compound is commercially available and is indexed as a food dye. Using this method, a detection limit of 0.05 nmol mL(-1) was achieved for peroxidase.

  13. Spectrophotometric and Spectrofluorimetric Methods for the Determination of Dothiepin Hydrochloride in its Pure and Dosage Forms using Eosin

    Walash, M. I.; Belal, F.; El-Enany, N.; Elmansi, H.

    2010-01-01

    Spectrophotometric and spectrofluorimetric methods were developed for the determination of dothiepin hydrochloride (DOP) in different dosage forms. The spectrophotometric method (Method I) is based on formation of a binary complex with eosin at 540 nm in acetate buffer of pH3.7. The absorbance-concentration plot is rectilinear over the range 1–10 μg/mL with LOD of 0.18 μg/mL and LOQ of 0.54 μg/mL. The spectroflurimetric method (Method II) is based on the quantitative quenching effect of Dothiepin on the native fluorescence of eosin at the same pH. The quenching of the fluorescence of eosin was measured at 543 nm after excitation at 304 nm. The fluorescence-concentration plot is rectilinear over the range 0.3–8 μg/ mL with LOD of 0.11 μg/mL and LOQ of 0.34 μg/mL. The proposed methods were successfully applied to the analysis of commercial tablets and capsules containing the drug. Statistical comparison of the results with those of the reference method revealed good agreement and proved that there were no significant differences in the accuracy and precision between the two methods respectively. PMID:23675210

  14. Performance Evaluation of Monolith Based Immobilized Acetylcholinesterase Flow-Through Reactor for Copper(II Determination with Spectrophotometric Detection

    Parawee Rattanakit

    2014-01-01

    Full Text Available A monolith based immobilized acetylcholinesterase (AChE flow-through reactor has been developed for the determination of copper(II using flow injection spectrophotometric system. The bioreactor was prepared inside a microcapillary column by in situ polymerization of butyl methacrylate, ethylene dimethacrylate, and 2,2-dimethoxy-1,2-diphynyletane-1-one in the presence of 1-decanol, followed by vinyl azlactone functionalization and AChE immobilization. The behavior of AChE before and after being immobilized on the monolith was evaluated by kinetic parameters from Lineweaver and Burk equation. The detection was based on measuring inhibition effect on the enzymatic activity of AChE by copper(II using Ellman’s reaction with spectrophotometric detection at 410 nm. The linear range of the calibration graph was obtained over the range of 0.02–3.00 mg L−1. The detection limit, defined as 10% inhibition (I10, was found to be 0.04 mg L−1. The repeatability was 3.35 % (n=5 for 1.00 mg L−1 of copper(II. The proposed method was applied to the determination of copper(II in natural water samples with sampling rate of 4 h−1.

  15. A New Spectrophotometric Method for Determination of Selenium in Cosmetic and Pharmaceutical Preparations after Preconcentration with Cloud Point Extraction

    Mohammad Hosein Soruraddin

    2011-01-01

    Full Text Available A simple, rapid, and sensitive spectrophotometric method for the determination of trace amounts of selenium (IV was described. In this method, all selenium spices reduced to selenium (IV using 6 M HCl. Cloud point extraction was applied as a preconcentration method for spectrophotometric determination of selenium (IV in aqueous solution. The proposed method is based on the complexation of Selenium (IV with dithizone at pH < 1 in micellar medium (Triton X-100. After complexation with dithizone, the analyte was quantitatively extracted to the surfactant-rich phase by centrifugation and diluted to 5 mL with methanol. Since the absorption maxima of the complex (424 nm and dithizone (434 nm overlap, hence, the corrected absorbance, Acorr, was used to overcome the problem. With regard to the preconcentration, the tested parameters were the pH of the extraction, the concentration of the surfactant, the concentration of dithizone, and equilibration temperature and time. The detection limit is 4.4 ng mL-1; the relative standard deviation for six replicate measurements is 2.18% for 50 ng mL-1 of selenium. The procedure was applied successfully to the determination of selenium in two kinds of pharmaceutical samples.

  16. Structural health monitoring and damage assessment using measured FRFs from multiple sensors. Part II. Decision making with RBF networks

    Zang, C.; Friswell, M.I. [Dept. of Aerospace Engineering, Univ. of Bristol, Bristol (United Kingdom); Imregun, M. [Dept. of Mechanical Engineering, Imperial Coll., London (United Kingdom)

    2003-07-01

    This paper is the second of two papers concerned with structural health monitoring and damage assessment using measured FRFs from multiple sensors, and discusses the decision making technique with radial basis function (RBF) neural networks. In PART 1 of the paper, the correlation criteria showed their capability to indicate various changes to the structure's state. PART 2, presented here, develops the methodology of decision theory to identify precisely all of the structure states. Although, the statistical approach can be used for classification, interpreting the information is difficult. Neural network techniques have been proven to possess many advantages for classification due to their learning ability and good generalization. In this paper, the radial basis function neural network is applied for function approximation and recognition. The key idea is to partition the input space (the indicators of the correlation criteria) into a number of subspaces that are in the form of hyper spheres. Then, the widely used k-mean clustering algorithm was selected as a logical approach to detecting the structure states. A bookshelf structure with measured frequency responses from 24 accelerometers was used to demonstrate the effectiveness of the method. The results show the successful classification of all structure states, for instance, the undamaged and damage states, damage locations and damage levels, and the environmental variability. (orig.)

  17. "What makes life good?" Developing a culturally grounded quality of life measure for Alaska Native college students.

    Sharma, Dinghy Kristine B; Lopez, Ellen D S; Mekiana, Deborah; Ctibor, Alaina; Church, Charlene

    2013-01-01

    Alaska Native (AN) college students experience higher attrition rates than their non-Native peers. Understanding the factors that contribute to quality of life ("what makes life good") for AN students will help inform supportive programs that are congruent with their culture and college life experiences. Co-develop a conceptual model and a measure of quality of life (QOL) that reflects the experiences of AN college students. Six focus groups were conducted with 26 AN college students. Within a community-academic partnership, interactive data collection activities, co-analysis workgroup sessions and an interactive findings forum ensured a participant-driven research process. Students identified and operationally defined eight QOL domains (values, culture and traditions, spirituality, relationships, basic needs, health, learning and leisure). The metaphor of a tree visually illustrates how the domains values, culture and traditions and spirituality form the roots to the other domains that appear to branch out as students navigate the dual worldviews of Native and Western ways of living. The eight QOL domains and their items identified during focus groups were integrated into a visual model and an objective QOL measure. The hope is to provide a useful tool for developing and evaluating university-based programs and services aimed toward promoting a positive QOL and academic success for AN students.

  18. Development and Validation of New Spectrophotometric Methods to Determine Enrofloxacin in Pharmaceuticals

    Rajendraprasad, N.; Basavaiah, K.

    2015-07-01

    Four spectrophotometric methods, based on oxidation with cerium(IV), are investigated and developed to determine EFX in pure form and in dosage forms. The frst and second methods (Method A and method B) are direct, in which after the oxidation of EFX with cerium(IV) in acid medium, the absorbance of reduced and unreacted oxidant is measured at 275 and 320 nm, respectively. In the third (C) and fourth (D) methods after the reaction between EFX and oxidant is ensured to be completed the surplus oxidant is treated with either N-phenylanthranilic acid (NPA) or Alizarin Red S (ARS) dye and the absorbance of the oxidized NPA or ARS is measured at 440 or 420 nm. The methods showed good linearity over the concentration ranges of 0.5-5.0, 1.25-12.5, 10.0-100.0, and 6.0-60.0 μg/ml, for method A, B, C and D, respectively, with apparent molar absorptivity values of 4.42 × 10 4 , 8.7 × 10 3 , 9.31 × 10 2 , and 2.28 × 10 3 l/(mol· cm). The limits of detection (LOD), quantification (LOQ), and Sandell's sensitivity values and other validation results have also been reported. The proposed methods are successfully applied to determine EFX in pure form and in dosage forms.

  19. SHARDS: a spectro-photometric analysis of distant red and dead massive galaxies

    Pérez-González, P. G.; Cava, A.; The Shards Team

    2013-05-01

    SHARDS, an ESO/GTC Large Program, is an ultra-deep (26.5 mag) spectro-photometric survey carried out with GTC/OSIRIS and designed to select and study massive passively evolving galaxies at z= 1.0--2.5 in the GOODS-N field. The survey uses a set of 24 medium band filters (FWHM ˜15 nm) covering the 500--950 nm spectral range. Our observing strategy has been planned to detect, for z>1 sources, the prominent Mg absorption feature (at rest-frame ˜280 nm), a distinctive, necessary, and sufficient feature of evolved stellar populations (older than 0.5 Gyr). These observations are being used to: (1) construct for the first time an unbiased sample of high-z quiescent galaxies, which extends to fainter magnitudes the samples selected with color techniques and spectroscopic surveys; (2) derive accurate ages and stellar masses based on robust measurements of spectral features such as the Mg(UV) or D(4000) indices; (3) measure their redshift with an accuracy Δ z/(1+z)<0.02; and (4) study emission-line galaxies (starbursts and AGN) up to very high redshifts. The well-sampled optical SEDs provided by SHARDS for all sources in the GOODS-N field are a valuable complement for current and future surveys carried out with other telescopes (e.g., Spitzer, HST, and Herschel).

  20. The role of self-reported impulsivity and reward sensitivity versus neurocognitive measures of disinhibition and decision making in the prediction of relapse in pathological gamblers

    Goudriaan, A.E.; Oosterlaan, J.; de Beurs, E.; van den Brink, W.

    2008-01-01

    Background: Disinhibition and decision-making skills play an important role in theories on the cause and outcome of addictive behaviors such as substance use disorders and pathological gambling. In recent studies, both disinhibition and disadvantageous decision-making strategies, as measured by

  1. The role of self-reported impulsivity and reward sensitivity versus neurocognitive measures of disinhibition and decision-making in the prediction of relapse in pathological gamblers

    Goudriaan, A. E.; Oosterlaan, J.; de Beurs, E.; van den Brink, W.

    2008-01-01

    BACKGROUND: Disinhibition and decision-making skills play an important role in theories on the cause and outcome of addictive behaviors such as substance use disorders and pathological gambling. In recent studies, both disinhibition and disadvantageous decision-making strategies, as measured by

  2. Spectrophotometric determination of total lactones in Andrographis paniculata Nees

    Napaporn Jantakun

    2005-11-01

    Full Text Available A spectrophotometric method for determination of total lactones in Andrographis paniculata was established by using dinitrobenzoic acid and potassium hydroxide solutions as colour forming agents. The absorbance of the solution was determined at 536 nm. The linearity range was 12-72 × 10-6 g.ml-1. The detection limit was 1.2 μg, the quantitation limit was 4.23 μg. The intraday variation had an average of slope 6082.97 g.ml-1, % RSD 0.10; an average intercept 0.2786, %RSD 3.66 (n=3. The interday variation had an average of 6146 g.ml-1 with the %RSD of 6.30 and an average intercept 0.2628, %RSD 4.95 (n=4. The coefficients of determination were 0.998-0.999. The total lactones content, calculated as andrographolide, determined by this method was 8.61±0.52% (n=4 and by the official method, Thai Herbal Pharmacopoeia, was 8.12±0.34% (n=2. The results of the two methods do not differ significantly at P=0.05 (P(|t|>0.903 = 0.53

  3. Verification of spectrophotometric method for nitrate analysis in water samples

    Kurniawati, Puji; Gusrianti, Reny; Dwisiwi, Bledug Bernanti; Purbaningtias, Tri Esti; Wiyantoko, Bayu

    2017-12-01

    The aim of this research was to verify the spectrophotometric method to analyze nitrate in water samples using APHA 2012 Section 4500 NO3-B method. The verification parameters used were: linearity, method detection limit, level of quantitation, level of linearity, accuracy and precision. Linearity was obtained by using 0 to 50 mg/L nitrate standard solution and the correlation coefficient of standard calibration linear regression equation was 0.9981. The method detection limit (MDL) was defined as 0,1294 mg/L and limit of quantitation (LOQ) was 0,4117 mg/L. The result of a level of linearity (LOL) was 50 mg/L and nitrate concentration 10 to 50 mg/L was linear with a level of confidence was 99%. The accuracy was determined through recovery value was 109.1907%. The precision value was observed using % relative standard deviation (%RSD) from repeatability and its result was 1.0886%. The tested performance criteria showed that the methodology was verified under the laboratory conditions.

  4. Rapid visual and spectrophotometric nitrite detection by cyclometalated ruthenium complex.

    Lo, Hoi-Shing; Lo, Ka-Wai; Yeung, Chi-Fung; Wong, Chun-Yuen

    2017-10-16

    Quantitative determination of nitrite ion (NO 2 - ) is of great importance in environmental and clinical investigations. A rapid visual and spectrophotometric assay for NO 2 - detection was developed based on a newly designed ruthenium complex, [Ru(npy)([9]aneS3)(CO)](ClO 4 ) (denoted as RuNPY; npy = 2-(1-naphthyl)pyridine, [9]aneS3 = 1,4,7-trithiacyclononane). This complex traps NO + produced in acidified NO 2 - solution, and yields observable color change within 1 min at room temperature. The assay features excellent dynamic range (1-840 μmol L -1 ) and high selectivity, and its limit of detection (0.39 μmol L -1 ) is also well below the guideline values for drinking water recommended by WHO and U.S. EPA. Practical use of this assay in tap water and human urine was successfully demonstrated. Overall, the rapidity and selectivity of this assay overcome the problems suffered by the commonly used modified Griess assays for nitrite determination. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Titanium Analysis of Ilmenite Bangka by Spectrophotometric Method Using Perhidrol

    Rusydi-S

    2004-01-01

    Determination of titanium by spectrofotometric method using perhydrol has been done. The purpose of experiment is to find out the condition of titanium analysis of ilmenite by spectrophotometric method. The experiment parameter e c. analysis condition include the Ti-perhydrol complex spectrum, acidity of complex, perhydrol concentration, linearity, influence of anion, limit detection, interfere elements, application of the method using 40 SRM Standard and analysis for ilmenite samples. Result of experiments are spectrum of Ti-perhydrol complex at 410 nm, acidity of complex is the H 2 SO 4 2 M, perhydrol concentration is 0,24 %, the curve calibration is linier at 1-80 ppm, anion of PO 4 , NO 3 , Cl, CO 3 not be influence until 2000 ppm, limit detection is 0,30 ppm and Mo, V is interfere. The method which was aplicated to 40 SRM standard, shown that the content of Ti is 1580 ppm while the standard is 1600 ppm, and the content of Ti from ilmenite high grade samples is 31,46 % and low grade is 13,55 %. (author)

  6. Spectrophotometric determination of nicradipine and isradipine in pharmaceutical formulations

    S. M. Al-Ghannam

    2009-05-01

    Full Text Available A sensitive spectrophotometric method was developed for the determination of some 1,4-dihydropyridine compounds namely, nicardipine and isradipine either in pure form or in pharmaceutical preparations. The method is based on the reduction of nicardipine and isradipine with zinc powder and calcium chloride followed by further reduction with sodium pentacyanoaminoferrate (II to give violet and red products having the absorbance maximum at 546 and 539 nm with nicardipine and isradipine, respectively. Beer’s law was obeyed over the concentration range 8.0–180 μg/ml with the detection limit of 1.67 μg/ml for nicardipine and 8.0–110 μg/ml with the detection limit of 1.748 μg/ml for isradipine. The analytical parameters and their effects on the reported methods were investigated. The molar absorptivity, quantization limit, standard deviation of intercept (Sa, standard deviation of slope (Sb and standard deviation of the residuals (Sy/x were calculated. The composition of the result compounds were found 1:1 for nicardipine and 1:2 for isradipine by Job’s method and the conditional stability constant (Kf and the free energy changes (ΔG were calculated for compounds formed. The proposed method was applied successfully for the determination of nicardipine and isradipine in their dosage forms. The results obtained were in good agreement with those obtained using the reference or official methods. A proposal of the reaction pathway was presented.

  7. Sensitive flow-injection spectrophotometric analysis of bromopride

    Lima, Liliane Spazzapam; Weinert, Patrícia Los; Pezza, Leonardo; Pezza, Helena Redigolo

    2014-12-01

    A flow injection spectrophotometric procedure employing merging zones is proposed for direct bromopride determination in pharmaceutical formulations and biological fluids. The proposed method is based on the reaction between bromopride and p-dimethylaminocinnamaldehyde (p-DAC) in acid medium, in the presence of sodium dodecyl sulfate (SDS), resulting in formation of a violet product (λmax = 565 nm). Experimental design methodologies were used to optimize the experimental conditions. The Beer-Lambert law was obeyed in a bromopride concentration range of 3.63 × 10-7 to 2.90 × 10-5 mol L-1, with a correlation coefficient (r) of 0.9999. The limits of detection and quantification were 1.07 × 10-7 and 3.57 × 10-7 mol L-1, respectively. The proposed method was successfully applied to the determination of bromopride in pharmaceuticals and human urine, and recoveries of the drug from these media were in the ranges 99.6-101.2% and 98.6-102.1%, respectively. This new flow injection procedure does not require any sample pretreatment steps.

  8. Spectrophotometric determination of nitrite in simulated Purex Process solutions

    Araujo, I.daC. de; Matsuda, H T; Araujo, B.F. de; Araujo, J.A. de

    1984-01-01

    A spectrophotometric method for nitrite determination in simulated Purex Process solutions is presented, utilizing the Griess reagent for the formation of the coloured azocompound with an absorption maximum at 525 nm. Molar absortivity was 36,262 and the sensitivity of the method 10/sup -6/M for nitrite. The calibration curve is linear in the range of 2 to 30..mu..g NO/sup -//sub 2//25 ml in cells of 1 cm optical path. The method can be used in the presence of uranium up to limits of an U/NO/sup -//sub 2/ ratio of 150. Test solutions were prepared to simulate composition and concentrations as obtained by irradiating standard fuel with a neutro flux of 3.2 x 10/sup 13/ n.s/sup -1/.cm/sup -2/, with a burn-up value of 33,000 Mwd/T and cooling time of two years. Nitrite determinations in these solutions were accurate within limits of 5%.

  9. Spectrophotometric assay of creatinine in human serum sample

    Avinash Krishnegowda

    2017-05-01

    Full Text Available A new spectrophotometric method for the analysis of creatinine concentration in human serum samples is developed. The method explores the oxidation of p-methylamino phenol sulfate (Metol in the presence of copper sulfate and creatinine which yields an intense violet colored species with maximum absorbance at 530 nm. The calibration graph of creatinine by fixed time assay ranged from 4.4 to 620 μM. Recovery of creatinine in human serum samples varied from 101% to 106%. Limit of detection and limit of quantification were 0.145 μM and 0.487 μM respectively. Sandell’s sensitivity was 0.112 μg cm−2 and molar absorptivity was 0.101 × 104 L mol−1 cm−1. Within day precision was 2.5–4.8% and day-to-day precision range was 3.2–7.8%. The robustness and ruggedness of the method expressed in RSD values ranged from 0.78% to 2.12% and 1.32% to 3.46% respectively, suggesting that the developed method was rugged. This method provides good sensitivity and is comparable to standard Jaffe’s method with comparatively less interference from foreign substances.

  10. Making better sense of the mosaic of environmental measurement networks: a system-of-systems approach and quantitative assessment

    P. W. Thorne

    2017-11-01

    Full Text Available There are numerous networks and initiatives concerned with the non-satellite-observing segment of Earth observation. These are owned and operated by various entities and organisations often with different practices, norms, data policies, etc. The Horizon 2020 project GAIA–CLIM is working to improve our collective ability to use an appropriate subset of these observations to rigorously characterise satellite observations. The first fundamental question is which observations from the mosaic of non-satellite observational capabilities are appropriate for such an application. This requires an assessment of the relevant, quantifiable aspects of the measurement series which are available. While fundamentally poor or incorrect measurements can be relatively easily identified, it is metrologically impossible to be sure that a measurement series is correct. Certain assessable aspects of the measurement series can, however, build confidence in their scientific maturity and appropriateness for given applications. These are aspects such as that it is well documented, well understood, representative, updated, publicly available and maintains rich metadata. Entities such as the Global Climate Observing System have suggested a hierarchy of networks whereby different subsets of the observational capabilities are assigned to different layers based on such assessable aspects. Herein, we make a first attempt to formalise both such a system-of-systems networks concept and a means by which to, as objectively as possible, assess where in this framework different networks may reside. In this study, we concentrate on networks measuring primarily a subset of the atmospheric Essential Climate Variables of interest to GAIA–CLIM activities. We show assessment results from our application of the guidance and how we plan to use this in downstream example applications of the GAIA–CLIM project. However, the approach laid out should be more widely applicable across

  11. TITRIMETRIC AND SENSITIVE SPECTRO-PHOTOMETRIC METHODS FOR THE ASSAY OF QUETIAPINE FUMARATE IN PHARMACEUTICAL FORMULATIONS

    Nagaraju Rajendraprasad

    2011-03-01

    Full Text Available Quetiapine fumarate (QTF is a selective monoaminergic antagonist with high affinity for the serotonin Type 2 (5HT2, and dopamine type 2 (D2 receptors. Titrimetric and spectrophotometric assay of quetiapine fumarate (QTF using perchloric acid and acetic acid as reagents are described. The first method (method A is a non-aqueous titrimetric method and is based on the titration of QTF in glacial acetic acid with 0.01 M acetous perchloric acid using crystal violet as indicator. In the second method (method B, QTF has been measured in 0.1M acetic acid spectrophotometrically at a wavelength of 222 nm. The titri¬metric method was applicable over the range of 2.0–20.0 mg of QTF. The reac¬tion stoichiometry of 1:3 is obtained which served as the basis for calculation. In spectrophotometry, Beer’s law was obeyed over the concentration range of 1.25–15.0 µg mL-1. The linear regression equation of the calibration graph was A = 0.0115 + 0.0673c with a regression coefficient (r of 0.9986 (n = 7. The apparent molar absorptivity was calculated to be 4.25104 L mol-1cm-1 and the Sandell sensitivity was 0.0145 µg cm-2. The limits of detection (LOD and quantification (LOQ calculated as per the ICH guidelines were 0.07 and 0.21 µg mL-1, respectively. Accuracy and precision of the assays were determined by computing the intra-day and inter-day variations at three different levels of QTF. The intra-day and inter-day relative standard deviation (%RSD were in the range of 0.99–2.88 and 1.65–2.32%, for method A and B, respectively, with an acceptable percentage relative error (%RE < 2%. The methods were successfully applied to the determination of QTF in two different brands of tablets with good accuracy and precision and without detectable interference by excipients. The methods have demonstrated to be simple and easy to apply in routine usage and do not need any costly instrumentation. Therefore, the proposed procedures are advantageous and can be

  12. A new innovative spectrophotometric method for the simultaneous determination of sofosbuvir and ledipasvir

    Mansour, Fotouh R.

    2018-01-01

    A new innovative spectrophotometric method is developed to determine the concentration ratios in binary mixtures by determining the zero crossing point in the first derivative of the gross curve. This relationship can be applied if the part of the UV spectrum of substance Y, that intersects with the overlaid spectra of substance X is straight. By plotting the intersection wavelength against the concentration ratio (Cx/Cy), a straight line was obtained with a co-efficient of determination equals 0.9999. As an application, simultaneous determination of sofosbuvir and ledipasvir in their binary mixtures was performed using two methods; a direct UV spectrophotometric method for determination of ledipasvir at 333 nm, and the new "wavelength-intersection ratio" method for determination of sofosbuvir. In the wavelength-intersection ratio method, different mixtures of sofosbuvir and ledipasvir containing different concentration ratios were prepared; the zero crossing point of the first derivative curve in the range 285 to 295 nm were determined for each mixture. An absorbance shift in the intersection was obtained with the change in the concentration ratio (sofosbuvir/ledipasvir). When the concentration ratio was plotted against the intersection wavelength, a straight line was obtained with a coefficient of determination of 0.9992. The direct method was linear in the range 3 to 18 μg/mL while the wavelength-intersection ratio method was linear in the range 11-110 μg/mL. The limits of detection were determined and found to be 0.5 and 3 μg/mL for ledipasvir and sofosbuvir, respectively. The accuracy and repeatability of the two methods were tested. The mean %recovery was found to be 100.19% and 100.75% for ledipasvir and sofosbuvir, respectively. The relative standard deviation was 0.57 for ledipasvir and 1.79 for sofosbuvir. The intermediate precision was also checked, the coefficients of variation for sofosbuvir and ledipasvir measurements between days did not exceed 1.88%.

  13. Insights into the concept and measurement of health literacy from a study of shared decision-making in a low literacy population.

    Smith, Sian K; Nutbeam, Don; McCaffery, Kirsten J

    2013-08-01

    This article explores the concept and measurement of health literacy in the context of shared health decision-making. It draws upon a series of qualitative and quantitative studies undertaken in the development and evaluation of a bowel cancer screening decision aid for low literacy populations. The findings indicate that different types of health literacy (functional, interactive and critical) are required in decision-making and present a set of instruments to assess and discriminate between higher level health literacy skills required for engagement in decision-making. It concludes that greater sophistication in both the definition and measurement of health literacy in research is needed.

  14. Development of spectrophotometric determination of beryllium in beryl minerals using chrome Azurol S

    Hisham K. Fouad

    2016-09-01

    Full Text Available A developed, direct, rapid, and sensitive spectrophotometric determination of beryllium in beryl minerals with Chrome Azurol S (CAS as a chromogenic reagent was developed in the present article. The determination was performed without either solvent extraction or ion exchange separation of beryllium from its matrix. The stable 1:1 Be-CAS complex was formed instantly with duration time of at least 24 h with constant absorbance. Different parameters such as wavelengths, pH, EDTA concentration and dye concentration were studied for the optimum determination of beryllium. Interference due to presence of high aluminum concentrations was overcome by adding 5% EDTA disodium salt solution. Maximum absorbance for Be-CAS complex was performed at λmax 568 NM using acetate buffer at pH 4.6. Beer’s law was obeyed in the range from 0.02 to 9 ppm with molar absorptivity ε = 0.22 × 104 mol−1 cm−1 and an average standard deviation of 0.7. The R.S.D for 10 replicate measurements of 1 ppm Be was 1.2%.

  15. Reverse flow injection spectrophotometric determination of thiram and nabam fungicides in natural water samples

    Asghar, M.; Yaqoob, M.; Nabi, A.

    2014-01-01

    A reverse flow injection (rFI) spectrophotometric method is reported for determination of thiram and nabam fungicides in natural water samples. The method is based on the reduction of iron(III) in the presence of thiram/nabam in acidic medium at 60 degree C and formation of iron(II)-ferricyanide complex was measured at 790 nm. The limits of detection (3s blank) were 0.01 and 0.05 micro g mL1 for thiram and nabam respectively with a sample throughput of 60 h1. Calibration graphs were linear over the range of 0.02 - 8.0 micro g mL1 (R2 = 0.9999, n = 8) and 0.1 - 30 micro g mL1 (R2 = 0.9982, n = 10) for thiram and nabam with relative standard deviations (RSDs; n = 3) in the range of 0.8 - 1.6% respectively. Experimental parameters and potential interferences were examined. Thiram and nabam were determined in natural water samples using solid-phase extraction (SPE) procedure and recoveries were in the range of 93+-3 - 105+-2% and 87+-4 - 102+-3% respectively. The results obtained were not significantly different compared with a HPLC method. (author)

  16. A spectrophotometric study of cerium IV and chromium VI species in nuclear fuel reprocessing process streams

    Nickson, I D; Boxall, C; Jackson, A; Whillock, G O H

    2010-01-01

    Nuclear fuel reprocessing schemes such as PUREX and UREX utilise HNO 3 media. An understanding of the corrosion of process engineering materials such as stainless steel in such media is a major concern for the nuclear industry. Two key species are cerium and chromium which, as Ce(IV), Cr(VI), may act as corrosion accelerants. An on-line analytical technique for these quantities would be useful for determining the relationship between corrosion rate and [Ce(IV)] and [Cr(VI)]. Consequently, a strategy for simultaneous quantification of Ce(IV), Cr(VI) and Cr(III) in the presence of other ions found in average burn-up Magnox / PWR fuel reprocessing stream (Fe, Mg, Nd, Al) is being developed. This involves simultaneous UV-vis absorbance measurement at 620, 540, 450 nm, wavelengths where Ce and Cr absorb but other ions do not. Mixed solutions of Cr(VI) and Ce(IV) are found to present higher absorbance values at 540 nm than those predicted from absorbances recorded from single component solutions of those ions. This is attributed to the formation of a 3:1 Cr(VI)-Ce(IV) complex and we report on the complexation and UV-visible spectrophotometric characteristics of this species. To the best of our knowledge this is the first experimental study of this complex in aqueous nitric acid solution systems.

  17. A simple spectrophotometric determination of trace amounts of vanadium using thionin

    Tom Cherian

    2005-12-01

    Full Text Available A simple and sensitive spectrophotometric method has been developed for the determination of trace amounts of vanadium using thionin as a chromogenic reagent. The proposed method is based on the reaction of vanadium(V with potassium iodide in acid medium to liberate iodine, which bleaches the violet colour of thionin and is measured at 600 nm. This decrease in absorbance is directly proportional to the vanadium(V concentration and obeys Beer's law in the range of 0.2-10 μgmL-1 of V(V. The molar absorptivity, Sandell's sensitivity, detection limit and quantitation limit of the method were found to be 2.298 x 104 Lmol-1cm-1, 0.52 x 10-2 μgcm-2, 0.035 μgmL-1 and 0.11 μgmL-1, respectively. The optimum reaction conditions and other analytical conditions were evaluated. The effect of interfering ions on the determination is described. The developed method has been successfully applied to the analysis of the vanadium in synthetic and alloy samples.

  18. Development of a flotation-spectrophotometric method for determination of cetylpyridinium chloride in pharmaceutical products

    Hooshang Parham

    2011-01-01

    Full Text Available A new simple and sensitive flotation-spectrophotometric method for the determination of cetylpyridinium chloride (CPC is reported. The method is based on the formation of an ion- associate between CPC and Orange II (OR which is floated in the interface of aqueous phase and n-hexane by vigorous shaking. The aqueous solution was discarded and the adsorbed ion associate on to the wall of a separating funnel was dissolved in a small volume of methanol solvent and its absorbance was measured at 480 nm. The apparent molar absorptivity (Ε of the ion associate was determined to be 4.12 x 10(5 L mol-1 cm-1. The calibration graph was linear in the concentration range of 15-800 ng mL-1 of CPC with a correlation coefficient of 0.9988. The limit of detection (LOD was 10.8 ng mL-1. The relative standard deviation (RSD for determination of 100 and 800 ng mL-1 of CPC was 3.47 and 2.04% (n=7, respectively. The method was successfully applied to the determination of CPC in a commercial mouth washer product.

  19. Spectrophotometric Determination of Gemifloxacin Mesylate, Moxifloxacin Hydrochloride, and Enrofloxacin in Pharmaceutical Formulations Using Acid Dyes

    Ayman A. Gouda

    2014-01-01

    Full Text Available Simple, rapid, and extractive spectrophotometric methods were developed for the determination of some fluoroquinolones antibiotics: gemifloxacin mesylate (GMF, moxifloxacin hydrochloride (MXF, and enrofloxacin (ENF in pure forms and pharmaceutical formulations. These methods are based on the formation of ion-pair complexes between the basic drugs and acid dyes, namely, bromocresol green (BCG, bromocresol purple (BCP, bromophenol blue (BPB, bromothymol blue (BTB, and methyl orange (MO in acidic buffer solutions. The formed complexes were extracted with chloroform and measured at 420, 408, 416, 415, and 422 nm for BCG, BCP, BPB, BTB, and MO, respectively, for GMF; at 410, 415, 416, and 420 nm for BCP, BTB, BPB, and MO, respectively, for MXF; and at 419 and 414 nm for BCG and BTB, respectively, in case of ENF. The analytical parameters and their effects are investigated. Beer’s law was obeyed in the ranges 1.0–30, 1.0–20, and 2.0–24 μg mL−1 for GMF, MXF, and ENF, respectively. The proposed methods have been applied successfully for the analysis of the studied drugs in pure forms and pharmaceutical formulations. Statistical comparison of the results with the reference methods showed excellent agreement and indicated no significant difference in accuracy and precision.

  20. Derivatization of labetalol hydrochloride for its spectrofluorimetric and spectrophotometric determination inhuman plasma: Application to stability study

    Omar, Mahmoud A.; Derayea, Sayed M.; Abdel-Lateef, Mohamed A.; El Hamd, Mohamed A.

    2018-02-01

    Two simple, selective and accurate methods were developed for the determination of Labetalol hydrochloride in pure form and pharmaceutical tablets. Both methods are based on derivatization of the studied drug with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBDsbnd Cl) in alkaline medium (pH 7.5).The reaction product was measured spectrofluorimetrically at 540 nm after excitation at 476 nm (method I) or spectrophotometrically at 480 nm (method II). The calibration graphs were rectilinear over the concentration ranges of 0.10-2.0 and 1.0-11.0 μg mL- 1 for methods I and II, respectively. The proposed methods were successfully applied to the analysis of commercial tablets without interference from common excipients. Furthermore, the spectrofluorimetric method was utilized for the in vitro determination of labetalol in spiked human plasma, with a percent mean recovery (n = 3) of 97.80 ± 1.29%. Moreover, the spectrofluorimetric method was extended to examine the stability study of LBT under different stress conditions such as alkaline, acidic, oxidative, photolytic and a thermal degradation.

  1. Spectrophotometric Evaluation of the Pulpal Peroxide Levels in Intact and Restored Teeth - An Invitro Study.

    Patri, Gaurav; Acharya, Gourismita; Agrawal, Pratik; Panda, Vijeta

    2016-08-01

    Hydrogen peroxide (30%) is a commonly used "in office" bleaching agent. Deleterious effects of hydrogen peroxide on the pulp have been observed. The present study was conducted with the aim to evaluate the penetration of 30% hydrogen peroxide into the pulp chamber through intact teeth and through the surface of teeth, restored with either hybrid composite or Resin Modified Glass Ionomer Cement (RMGIC). Sixty extracted human maxillary central incisors were selected and divided into six groups. Two groups were restored with hybrid composite resin and two with RMGIC, while two groups were left intact. The teeth with acetate buffer solution in their pulp cavity were then immersed in either 30% hydrogen peroxide or distilled water depending upon the group, for 60 minutes at 37°C. Then horseradish peroxidase and leucocrystal violet were added to the acetate buffer solution present in the pulp chamber after it was transferred to a test tube and the optical density of the resultant blue solution obtained was measured spectrophotometrically. The data obtained were analyzed using one way ANOVA and Student's t-test. The data obtained established that hydrogen peroxide penetrated into the pulp from the bleaching agent used. Hydrogen peroxide (30%) showed the highest pulpal peroxide level in teeth restored with RMGIC followed by teeth restored with hybrid composite resin and the least amount of penetration was observed in intact teeth. The amount of peroxide penetration into the tooth is more through restored tooth than intact tooth and is also dependant on the type of restorative materials used.

  2. Sensitization of glycine (spectrophotometric read-out) dosimetric system using sorbitol

    Shinde, S.H.; Mukherjee, T.

    2009-01-01

    Glycine spectrophotometric read-out systems have a useful dose range of 15-4000 Gy. An attempt was made to sensitize it using sorbitol as a sensitizer. Optimum compositions of aqueous acidic solutions of ferrous ammonium sulphate-xylenol orange (XO), i.e. FX and sorbitol-ferrous ammonium sulphate-xylenol orange, i.e. SFX, for 400 mg of glycine, which gives maximum dosimetric response for any given dose, were established. Molar absorption coefficient values of ferric-XO-glycine complex, i.e. ε-values, were determined for glycine system in FX and SFX. These values were found to be 8410 and 15,000 m 2 mol -1 respectively, indicating that an enhancement or sensitivity factor of about 1.78 can be achieved by sorbitol for glycine in SFX. This factor was further confirmed by measuring the gamma dose response of glycine in FX and in SFX for four different doses, viz. 37.8, 75.5, 151 and 302 Gy. It was observed that dose response of glycine in SFX is about 77% more than that of glycine in FX. The maximum variation observed in response of glycine in FX or SFX was found to be within ±1.5%.

  3. Process monitored spectrophotometric titration coupled with chemometrics for simultaneous determination of mixtures of weak acids.

    Liao, Lifu; Yang, Jing; Yuan, Jintao

    2007-05-15

    A new spectrophotometric titration method coupled with chemometrics for the simultaneous determination of mixtures of weak acids has been developed. In this method, the titrant is a mixture of sodium hydroxide and an acid-base indicator, and the indicator is used to monitor the titration process. In a process of titration, both the added volume of titrant and the solution acidity at each titration point can be obtained simultaneously from an absorption spectrum by least square algorithm, and then the concentration of each component in the mixture can be obtained from the titration curves by principal component regression. The method only needs the information of absorbance spectra to obtain the analytical results, and is free of volumetric measurements. The analyses are independent of titration end point and do not need the accurate values of dissociation constants of the indicator and the acids. The method has been applied to the simultaneous determination of the mixtures of benzoic acid and salicylic acid, and the mixtures of phenol, o-chlorophenol and p-chlorophenol with satisfactory results.

  4. Sensitive kinetic spectrophotometric determination of captopril and ethamsylate in pharmaceutical preparations and biological fluids.

    El-Shabrawy, Y; El-Enany, N; Salem, K

    2004-10-01

    A highly sensitive kinetic spectrophotometric method was developed for the determination of captopril (CPL) and ethamsylate (ESL) in pharmaceutical preparations and biological fluids. The method is based on a catalytic acceleration of the reaction between sodium azide and iodine in an aqueous solution. Concentration range of 0.1-1.5 microg ml(-1) for CPL and 0.3-3 microg ml(-1) for ESL was determined by measuring the decrease in the absorbance of iodine at 348 nm by a fixed time method. The decrease in absorbance after 5 min was markedly correlated to the concentration. The relative standard deviations obtained were 1.30 and 1.87 for CPL and ESL, respectively, in pure forms. Correlation coefficients were 0.9997 and 0.9999 for CPL and ESL, respectively. The detection limits were determined as (S/N = 3) were 20 ng ml(-1) for CPL and 50 ng ml(-1) for ESL. The proposed procedure was successively applied for the determination of both drugs in pharmaceutical preparations and in biological fluids.

  5. A nanosilver-based spectrophotometric method for determination of malachite green in surface water samples.

    Sahraei, R; Farmany, A; Mortazavi, S S; Noorizadeh, H

    2013-07-01

    A new spectrophotometric method is reported for the determination of nanomolar level of malachite green in surface water samples. The method is based on the catalytic effect of silver nanoparticles on the oxidation of malachite green by hexacyanoferrate (III) in acetate-acetic acid medium. The absorbance is measured at 610 nm with the fixed-time method. Under the optimum conditions, the linear range was 8.0 × 10(-9)-2.0 × 10(-7) mol L(-1) malachite green with a correlation coefficient of 0.996. The limit of detection (S/N = 3) was 2.0 × 10(-9) mol L(-1). Relative standard deviation for ten replicate determinations of 1.0 × 10(-8) mol L(-1) malachite green was 1.86%. The method is featured with good accuracy and reproducibility for malachite green determination in surface water samples without any pre-concentration and separation step.

  6. Sensitive and selective spectrophotometric determination of pantoprazole sodium in pharmaceuticals using permanganate

    K. B. VINAY

    2010-03-01

    Full Text Available A simple visible spectrophotometric method is described for the determination of pantoprazole sodium sesquihydrate (PSS. The method is based on the formation of a brown colored product on treating PSS with permanganate in neutral medium, the absorbance being measured at 350 nm. The experimental conditions for the assay were optimized. The absorbance is found to increase linearly with the concentration of PSS and the calibration graph is linear in the range of 2.5-40.0 μg ml-1 with a linear regression coefficient of 0.998. The calculated molar absorptivity value is 1.27x104 l mol-1 cm-1 and the corresponding Sandel sensitivity is 0.0341 µg cm-2. The limits of detection (LOD and quantification (LOQ are calculated to be 0.49 and 1.47 µg ml-1, respectively. Intra-day and inter-day accuracy expressed as relative error were better than 2.0% and the corresponding precision (RSD was less than 2.5 %. The developed and validated method was applied to the determination of the active ingredient in a tablet dosage form and the results obtained agreed well with those of the reference method. The accuracy and reliability of the method were ascertained by performing recovery experiments via standard-addition procedure.

  7. Challenges and solutions for the analysis of in situ, in crystallo micro-spectrophotometric data

    Dworkowski, Florian S. N.; Hough, Michael A.; Pompidor, Guillaume; Fuchs, Martin R.

    2015-01-01

    The particular challenge of the analysis of optical absorption and Raman spectroscopic data measured from protein crystals and how the SLS-APE software toolbox supports scientists in dealing with such data is described. Combining macromolecular crystallography with in crystallo micro-spectrophotometry yields valuable complementary information on the sample, including the redox states of metal cofactors, the identification of bound ligands and the onset and strength of undesired photochemistry, also known as radiation damage. However, the analysis and processing of the resulting data differs significantly from the approaches used for solution spectrophotometric data. The varying size and shape of the sample, together with the suboptimal sample environment, the lack of proper reference signals and the general influence of the X-ray beam on the sample have to be considered and carefully corrected for. In the present article, how to characterize and treat these sample-dependent artefacts in a reproducible manner is discussed and the SLS-APEin situ, in crystallo optical spectroscopy data-analysis toolbox is demonstrated

  8. Simultaneous in-line concentration for spectrophotometric determination of cations and anions

    Rocha Fábio R. P

    2004-01-01

    Full Text Available A flow system is proposed for simultaneous in-line concentration of cations and anions. A sliding-bar commutator was employed to insert an anion and a cation exchange column into a flowing sample stream for serial retention of the analytes. In the injector alternative position, different solutions flowed through the columns for parallel elution of the species in different analytical paths. Three-way solenoid valves allowed the intermittent reagent introduction in the sample zones. Signals were measured by employing two flow-through LED-based detectors. The simultaneous retention of the sample zones in coiled reactors can be also performed to increase the residence time and the analyte conversion rate. The analytical potentiality was demonstrated by the in-line concentration of ammonium and phosphate followed by spectrophotometric detection. For a 90 s loading time, the sampling rate was estimated as 40 determinations per hour, which is three-fold higher than the obtained without performing the tasks simultaneously. Enrichment factors of 8.0 and 18 were estimated for phosphate and ammonium, respectively, yielding detection limits of 1 mg L-1 PO4(3- and 1 mg L-1 NH4+ (99.7% confidence level. The reagent consumption was lower than 2 mg per determination. Results for freshwater samples agreed with the obtained by reference APHA procedures at the 95% confidence level.

  9. Different Spectrophotometric Methods for Simultaneous Determination of Trelagliptin and Its Acid Degradation Product

    Hassan, Mostafa A.; Zaghary, Wafaa A.

    2018-01-01

    New spectrophotometric and chemometric methods were carried out for the simultaneous assay of trelagliptin (TRG) and its acid degradation product (TAD) and applied successfully as a stability indicating assay to recently approved Zafatek® tablets. TAD was monitored using TLC to ensure complete degradation. Furthermore, HPLC was used to confirm dealing with one major acid degradation product. The proposed methods were developed by manipulating zero-order, first-derivative, and ratio spectra of TRG and TAD using simultaneous equation, first-derivative, and mean-centering methods, respectively. Using Spectra Manager II and Minitab v.14 software, the absorbance at 274 nm–260.4 nm, amplitudes at 260.4 nm–274.0 nm, and mean-centered values at 287.6 nm–257.2 nm were measured against methanol as a blank for TRG and TAD, respectively. Linearity and the other validation parameters were acceptable at concentration ranges of 5–50 μg/mL and 2.5–25 μg/mL for TRG and TAD, respectively. Using one-way analysis of variance (ANOVA), the optimized methods were compared and proved to be accurate for the simultaneous assay of TRG and TAD. PMID:29629213

  10. The Gaia spectrophotometric standard stars survey: II. Instrumental effects of six ground-based observing campaigns

    Altavilla, G.; Marinoni, S.; Pancino, E.; Galleti, S.; Ragaini, S.; Bellazzini, M.; Cocozza, G.; Bragaglia, A.; Carrasco, J. M.; Castro, A.; Di Fabrizio, L.; Federici, L.; Figueras, F.; Gebran, M.; Jordi, C.; Masana, E.; Schuster, W.; Valentini, G.; Voss, H.

    2015-08-01

    The Gaia SpectroPhotometric Standard Stars (SPSS) survey started in 2006, was awarded almost 450 observing nights and accumulated almost 100 000 raw data frames with both photometric and spectroscopic observations. Such large observational effort requires careful, homogeneous, and automatic data reduction and quality control procedures. In this paper, we quantitatively evaluate instrumental effects that might have a significant (i.e., ≥ 1 %) impact on the Gaia SPSS flux calibration. The measurements involve six different instruments, monitored over the eight years of observations dedicated to the Gaia flux standards campaigns: DOLORES@TNG in La Palma, EFOSC2@NTT and ROSS@REM in La Silla, CAFOS@2.2 m in Calar Alto, BFOSC@Cassini in Loiano, and LaRuca@1.5 m in San Pedro Mártir. We examine and quantitatively evaluate the following effects: CCD linearity and shutter times, calibration frames stability, lamp flexures, second order contamination, light polarization, and fringing. We present methods to correct for the relevant effects which can be applied to a wide range of observational projects at similar instruments. Based on data obtained with BFOSC@Cassini in Loiano, Italy; EFOSC2@NTT in La Silla, Chile; DOLORES@TNG in La Palma, Spain; CAFOS@2.2 m in Calar Alto, Spain; LaRuca@1.5 m in San Pedro Mártir, Mexico (see acknowledgements for more details).

  11. Extractive Spectrophotometric Determination of Nortriptyline Hydrochloride Using Sudan II, IV and Black B.

    Amin, A S; Saleh, H M

    2017-08-17

    A simple spectrophotometric methods has been developed for the determination of nortriptyline hydrochloride in pure and in pharmaceuticalformulations based on the formation of ion-pair complexes with sudun II (S II ), sudan (IV) (S IV ) and sudan black B (S BB ). The selectivity of the method was improved through extraction with chloroform. The optimum conditions for complete extracted colour development were assessed. The absorbance measurements were made at 534, 596 and 649 nm for S II , S IV and S BB complexes, respectively. The calibration graph was linear in the ranges 0.5- 280. 0.5- 37.5 and 0.5 - 31.0 μg ml -1 of the drug usiny the same reagents, respectively. The precision of the procedure was checked by calculating the relative standard deviation of ten replicate determinations on 15 μg ml -1 of nortriptyline HCI and was found to be 1.7, 1.3 and 1.55% using S II , S IV , and S BB complexes, respectively. The molar absorptivity and Sandell sensitivity for each ion-pair were calculated. The proposed methods were successfully applied to the deterniination of pure nortriptyline HCI and in pharmaceutical formulations, and the results demonstrated that the method is equally accurate, precise and reproducible as the official method.

  12. Development of a Direct Spectrophotometric and Chemometric Method for Determining Food Dye Concentrations.

    Arroz, Erin; Jordan, Michael; Dumancas, Gerard G

    2017-07-01

    An ultraviolet visible (UV-Vis) spectrophotometric and partial least squares (PLS) chemometric method was developed for the simultaneous determination of erythrosine B (red), Brilliant Blue, and tartrazine (yellow) dyes. A training set (n = 64) was generated using a full factorial design and its accuracy was tested in a test set (n = 13) using a Box-Behnken design. The test set garnered a root mean square error (RMSE) of 1.79 × 10 -7 for blue, 4.59 × 10 -7 for red, and 1.13 × 10 -6 for yellow dyes. The relatively small RMSE suggests only a small difference between predicted versus measured concentrations, demonstrating the accuracy of our model. The relative error of prediction (REP) for the test set were 11.73%, 19.52%, 19.38%, for blue, red, and yellow dyes, respectively. A comparable overlay between the actual candy samples and their replicated synthetic spectra were also obtained indicating the model as a potentially accurate method for determining concentrations of dyes in food samples.

  13. Spectrophotometric determination of boron in complex matrices by isothermal distillation of borate ester into curcumin

    Thangavel, S.; Dhavile, S.M.; Dash, K.; Chaurasia, S.C.

    2004-01-01

    In situ distillation of borate ester into the curcumin solution has been developed for the spectrophotometric determination of boron in a variety of complex matrixes. A polypropylene vessel containing the sample solution was placed inside a vessel (PP) containing 10 ml of curcumin solution and the distillation was carried out at room temperature/on a water bath. The borate ester collected in to the curcumin solution was evaporated to dryness on the water bath, taken in acetone and the absorbance was measured at 550 nm. In situ distillation of borate ester directly into the chromogenic reagent eliminates tedious sample treatment (before and/or after borate separation), use of methanol, complicated quartz set up, possible loss of boron and reduces the analysis time significantly. In situ dehydration of sample solution by ethanolic vapour in the absence of dehydrating acid prevents the formation of fluoborate and co-distillation of potential anionic interferents (nitrate and fluoride). This developed method has been applied for the determination of traces of boric acid in boron powder by the distillation of methyl borate at room temperature. For other matrixes (water, uranium oxide, uranyl nitrate, fluoride salt, etc.) distillation of ethyl borate was carried out on the water bath. LOD (3σ) was 5 ng g -1 for water and 30 ng g -1 for solid samples

  14. Derivative spectrophotometric determination of trace amounts of Tungsten(VI) in real water samples

    Viswanatha, C.; Ramakrishna Reddy, K.; Devanna, N.; Praveen Kumar, M.D.

    2012-01-01

    2,4-Dimethoxybenzaldehydeisonicotinoylhydrazone (DMBHIH) has been synthesized and characterized with IR, NMR and Mass Spectroscopic methods. A simple and derivative spectrophotometric method has been developed for the determination of trace amounts of W(VI). The reagent forms a yellow coloured water soluble complex with W(VI) in basic medium (pH 8.0). The molar absorptivity and Sandell's sensitivity of coloured species are 3.43 x 10 4 L.mol -1 cm -1 and 0.0049 μg/cm 2 respectively. Beer's law is obeyed in the range 0.4113-6.2138 μg/ml of W(VI) at λ max 394 nm. W(VI) forms 1:1 complex with DMBHIH and stability constant of the complex was 5.22x10 6 . The first and second derivative amplitude was measured at 453 nm and 468 nm. The developed method applied for the determination of W(VI) in alloys and biological samples. (author)

  15. Analytical method development and validation of spectrofluorimetric and spectrophotometric determination of some antimicrobial drugs in their pharmaceuticals

    Ibrahim, F.; Wahba, M. E. K.; Magdy, G.

    2018-01-01

    In this study, three novel, sensitive, simple and validated spectrophotometric and spectrofluorimetric methods have been proposed for estimation of some important antimicrobial drugs. The first two methods have been proposed for estimation of two important third-generation cephalosporin antibiotics namely, cefixime and cefdinir. Both methods were based on condensation of the primary amino group of the studied drugs with acetyl acetone and formaldehyde in acidic medium. The resulting products were measured by spectrophotometric (Method I) and spectrofluorimetric (Method II) tools. Regarding method I, the absorbance was measured at 315 nm and 403 nm with linearity ranges of 5.0-140.0 and 10.0-100.0 μg/mL for cefixime and cefdinir, respectively. Meanwhile in method II, the produced fluorophore was measured at λem 488 nm or 491 nm after excitation at λex 410 nm with linearity ranges of 0.20-10.0 and 0.20-36.0 μg/mL for cefixime and cefdinir, respectively. On the other hand, method III was devoted to estimate nifuroxazide spectrofluorimetrically depending on formation of highly fluorescent product upon reduction of the studied drug with Zinc powder in acidic medium. Measurement of the fluorescent product was carried out at λem 335 nm following excitation at λex 255 nm with linearity range of 0.05 to 1.6 μg/mL. The developed methods were subjected to detailed validation procedure, moreover they were used for the estimation of the concerned drugs in their pharmaceuticals. It was found that there is a good agreement between the obtained results and those obtained by the reported methods.

  16. A Novel Method making direct use of AIRS and IASI Calibrated Radiances for Measuring Trends in Surface Temperatures

    Aumann, H. H.; Ruzmaikin, A.

    2014-12-01

    Making unbiased measurements of trends in the surface temperatures, particularly on a gobal scale, is challenging: While the non-frozen oceans temperature measurements are plentiful and accurate, land and polar areas are much less accurately or fairly sampled. Surface temperature deduced from infrared radiometers on polar orbiting satellites (e.g. the Atmospheric Infrared Sounder (AIRS) at 1:30PM, the Interferometer Atmosphere Sounding Interferometer (IASI) at 9:30 AM and the MODerate resolution Imaging Spectro-radiometer (MODIS) at 1:30PM), can produce what appear to be well sampled data, but dealing with clouds either by cloud filtering (MODIS, IASI) or cloud-clearing (AIRS) can create sampling bias. We use a novel method: Random Nadir Sampling (RNS) combined with Probability Density Function (PDF) analysis. We analyze the trend in the PDF of st1231, the water vapor absorption corrected brightness temperatures measured in the 1231 cm-1 atmospheric window channel. The advantage of this method is that trends can be directly traced to the known, less than 3 mK/yr trend for AIRS, in st1231. For this study we created PDFs from 22,000 daily RNS from the AIRS and IASI data. We characterized the PDFs by its daily 90%tile value, st1231p90, and analysed the statistical properties of the this time series between 2002 and 2014. The method was validated using the daily NOAA SST (RTGSST) from the non-frozen oceans: The mean, seasonal variability and anomaly trend of st1231p90 agree with the corrsponding values from the RTGSST and the anomaly correlation is larger than 0.9. Preliminary results (August 2014) confirm the global hiatus in the increase of the globally averaged surface temperatures between 2002 and 2014, with a change of less than 10 mK/yr. This uncertainty is dominated by the large interannual variability related to El Niño events. Further insite is gained by analyzing land/ocean, day/night, artic and antarctic trends. We observe a massive warming trend in the

  17. [Derivative spectrophotometric and NMR spectroscopic study in pharmaceutical science].

    Kitamura, Keisuke

    2007-10-01

    This review starts with an introduction of derivative spectrophotometry followed by a description on the construction of a personal computer-assisted derivative spectrophotometric (DS) system. An acquisition system for inputting digitalized absorption spectra into personal computers and a BASIC program for calculating derivative spectra were developed. Then, applications of the system to drug analyses that are difficult with traditional absorption methods are described. Following this, studies on the interactions of drugs with biological macromolecules by the DS and NMR methods were discussed. An (1)H NMR study elucidated that the small unilamellar vesicle (SUV) has a single membrane made of a phosphatidylcholine bilayer, and that chlorpromazine interacts with both the outer and inner layers. (13)C NMR revealed a reduction of the dissociation constants of phenothiazine drugs due to their interaction with SUV. The partition coefficients of phenothiazine, benzodiazepine and steroid drugs in an SUV-water system and the effects of cholesterol or amino lipids content on these partition coefficients were examined by the DS method. The binding constants of phenothiazine drugs to bovine serum albumin (BSA) and the influence of Na(+), K(+), Cl(-), Br(-), and I(-) on these binding constants were determined by DS. It was found that I(-), Br(-), Cl(-) reduce the binding constants in this order, and that Na(+) and K(+) have no effect. A (19)F NMR study revealed that triflupromazine binds to BSA and human serum albumin in two regions including Site II with different populations, and that a nonsteroidal anti-inflammatory drug, niflumic acid, binds Sites Ia and Ib.

  18. Application and validation of superior spectrophotometric methods for simultaneous determination of ternary mixture used for hypertension management

    Mohamed, Heba M.; Lamie, Nesrine T.

    2016-02-01

    Telmisartan (TL), Hydrochlorothiazide (HZ) and Amlodipine besylate (AM) are co-formulated together for hypertension management. Three smart, specific and precise spectrophotometric methods were applied and validated for simultaneous determination of the three cited drugs. Method A is the ratio isoabsorptive point and ratio difference in subtracted spectra (RIDSS) which is based on dividing the ternary mixture of the studied drugs by the spectrum of AM to get the division spectrum, from which concentration of AM can be obtained by measuring the amplitude values in the plateau region at 360 nm. Then the amplitude value of the plateau region was subtracted from the division spectrum and HZ concentration was obtained by measuring the difference in amplitude values at 278.5 and 306 nm (corresponding to zero difference of TL) while the total concentration of HZ and TL in the mixture was measured at their isoabsorptive point in the division spectrum at 278.5 nm (Aiso). TL concentration is then obtained by subtraction. Method B; double divisor ratio spectra derivative spectrophotometry (RS-DS) and method C; mean centering of ratio spectra (MCR) spectrophotometric methods. The proposed methods did not require any initial separation steps prior the analysis of the three drugs. A comparative study was done between the three methods regarding their; simplicity, sensitivity and limitations. Specificity was investigated by analyzing the synthetic mixtures containing different ratios of the three studied drugs and their tablets dosage form. Statistical comparison of the obtained results with those found by the official methods was done, differences were non-significant in regard to accuracy and precision. The three methods were validated in accordance with ICH guidelines and can be used for quality control laboratories for TL, HZ and AM.

  19. Extractive spectrophotometric determination of molybdenum using p-chloroisonitroso acetophenone hydrazone

    Lokhande, R.S.; Agashe, A.P.; Hundiwale, D.G.

    2001-01-01

    Separation technique like solvent extraction can be advantageously employed for the determination of metals at low concentration in micrograms using spectrophotometric methods. Hydrazoxine has been used for the extraction and spectrophotometric determination of metals at trace level as well as for the studies of transition metals in complex form. In the present paper, solvent extraction technique has been used to develop methods for the separation and spectrophotometric determination of Mo(VI) with p-chloroisonitroso acetophenone hydrazone was extracted into chloroform from aqueous solution in the pH range 8 to 8.5. The absorption maxima was also tried for the extracted species and Beer's law was also studied for its applicability. In this, interference from the foreign ion has also been examined. (author)

  20. Yonsei Evolutionary Population Synthesis (YEPS). II. Spectro-photometric Evolution of Helium-enhanced Stellar Populations

    Chung, Chul; Yoon, Suk-Jin; Lee, Young-Wook, E-mail: chulchung@yonsei.ac.kr, E-mail: sjyoon0691@yonsei.ac.kr [Center for Galaxy Evolution Research, Yonsei University, Seoul 03722 (Korea, Republic of)

    2017-06-20

    The discovery of multiple stellar populations in Milky Way globular clusters (GCs) has stimulated various follow-up studies on helium-enhanced stellar populations. Here we present the evolutionary population synthesis models for the spectro-photometric evolution of simple stellar populations (SSPs) with varying initial helium abundance ( Y {sub ini}). We show that Y {sub ini} brings about dramatic changes in spectro-photometric properties of SSPs. Like the normal-helium SSPs, the integrated spectro-photometric evolution of helium-enhanced SSPs is also dependent on metallicity and age for a given Y {sub ini}. We discuss the implications and prospects for the helium-enhanced populations in relation to the second-generation populations found in the Milky Way GCs. All of the models are available at http://web.yonsei.ac.kr/cosmic/data/YEPS.htm.

  1. Yonsei Evolutionary Population Synthesis (YEPS). II. Spectro-photometric Evolution of Helium-enhanced Stellar Populations

    Chung, Chul; Yoon, Suk-Jin; Lee, Young-Wook

    2017-01-01

    The discovery of multiple stellar populations in Milky Way globular clusters (GCs) has stimulated various follow-up studies on helium-enhanced stellar populations. Here we present the evolutionary population synthesis models for the spectro-photometric evolution of simple stellar populations (SSPs) with varying initial helium abundance ( Y ini ). We show that Y ini brings about dramatic changes in spectro-photometric properties of SSPs. Like the normal-helium SSPs, the integrated spectro-photometric evolution of helium-enhanced SSPs is also dependent on metallicity and age for a given Y ini . We discuss the implications and prospects for the helium-enhanced populations in relation to the second-generation populations found in the Milky Way GCs. All of the models are available at http://web.yonsei.ac.kr/cosmic/data/YEPS.htm.

  2. Extraction-spectrophotometric method for silicon determination in high-purity substances. 1. Silicon determination in tellurium

    Shaburova, V P; Yudelevich, I G [AN SSSR, Novosibirsk (USSR). Inst. Neorganicheskoj Khimii

    1989-01-01

    The extraction-spectrophotometric method for silicon determination in tellurium based on extraction isolation of the base by tributyl phosphate from hydrochloride solutions and with addition of HNO/sub 3/ and spectrophotometric silicon determination using malachite green is developed. The method permits to determine 2x10/sup -1/-3x10/sup -4/ % Si.

  3. Development and Validation of UV Spectrophotometric Method For Determination of Bisoprolol Fumarate in Bulk and Pharmaceutical Dosage Forms

    Shahinaz Mohammed

    2017-10-01

    Full Text Available In this study a simple, accurate and precise UV- spectrophotometric method was developed for the estimation of bisoprolol fumarate (BF in bulk and tablet dosage form. The method was based on measurement of absorbance of BF aqueous solution at 225 nm. Validation was conducted in accordance to ICH guidelines. The calibration curve was linear in the concentration range 5.0-30.0 µg/mL with correlation coefficient not less than 0.996. The limit of detection and limit of quantification were 0.22 μg/ml and 0.66 μg/ml, respectively. Intraday and intermediate precision of the developed method were reflected by the low RSD% values (1.19 and 0.854, respectively. The recovery percentage was 100.6 ± 0.6%, n=3. The proposed method was applied for the assay of BF in three different brands.

  4. Sensitive flotation-spectrophotometric determination of gold, based on the gold(I)-iodide-methylene blue system.

    Marczenko, Z; Jankowski, K

    1985-04-01

    The gold(I)-iodide-Methylene Blue (MB) system is suitable for flotation separation and spectrophotometric determination of gold. Under the optimum conditions [(MB(+))(AuI(2)(-))].3[(MB(+))(I(3)(-))] is formed, and floated with cyclohexane. The product is dissolved in methanol and its absorbance measured. The molar absorptivity is 3.4 x 10(5)1.mole(-1).cm(-1) at 655 nm. The proposed method is more than three times as sensitive as the Rhodamine B method. Pt, Pd, Ag and Hg interfere seriously, and Ir, Rh, Bi and Cd to a smaller extent. Preliminary separation of gold by precipitation with tellurium as a collector is recommended. The method has been applied to determination of gold traces (about 1 x 10(-4)%) in a copper sample.

  5. Spectrophotometric determination of cerium with methylthymol blue in the presence of oxalate and cyanide as masking agents

    Cabrera-Martin, A; Izquierdo-Hornillos, R; Quejido-Cabezas, A J; Peral-Fernandez, J L [Universidad Complutense de Madrid (Spain). Facultad de Ciencias Quimicas

    1983-04-01

    The spectrophotometric determination of cerium can be carried out by several methods, which involve either the formation of complexes of cerium(III) and cerium(IV) or the oxidation of suitable reagents by cerium(IV) and further measuring the intensity of the colour of the oxidised matter. The latter methods show a lack of selectivity and low sensitivity owing to the nature of the redox reaction. The methods that involve the formation of complexes have also been shown to have low selectivity and sensitivity. However, the most useful methods are those based on the complexes of cerium(III) with Xylenol Orange and Methylthymol Blue (MTB), but they are affected by many interferences. In this work the reaction of cerium(III) with MTB in the presence of oxalate and cyanide ions was studied at pH 10.2, which improves the sensitivity and the selectivity of the determination of cerium.

  6. Development of a microtitre-based spectrophotometric method to monitor Babesia divergens growth in vitro.

    Malandrin, Laurence; Marchand, Anne-Marie; Chauvin, Alain

    2004-09-01

    Babesia divergens multiplication cycle involves erythrocyte invasion, intracellular division, and erythrocyte lysis with the simultaneous liberation of hemoglobin. We have decided to set up a spectrophotometric protocol based on hemoglobin concentration in the culture supernatants to monitor B. divergens in vitro growth. After the selection of 405 nm as the most appropriate endpoint hemoglobin wavelength in our conditions (hemoglobin concentration in the supernatant), cultures were standardized [1 x 10(9) red blood cell (RBC)/ml, 1-2.5 x 10(5) infected red blood cell (iRBC)/ml] to allow their monitoring over 3 days. The protocol was then compared to the most commonly used growth measurement methods: parasitemia counting and [(3)H]hypoxanthine incorporation. An excellent correlation was demonstrated between A(405) of the culture supernatant and parasitemia of the iRBC, whatever the RBC concentration used in the medium. This correlation was also evidenced between A(405) and [(3)H]hypoxanthine incorporation for [(3)H]hypoxanthine concentrations lower than 4 microCi/ml. Our assays also highlighted the inhibitory effect of [(3)H]hypoxanthine on B. divergens growth even when used at low concentrations (0.8 microCi/ml) and for a short incorporation duration (24 h). This effect was confirmed by both A(405) and parasitemia counting. In conclusion, A(405) measurement of B. divergens culture supernatant represents a simple, rapid, safe, and reliable way to measure the in vitro growth of this parasite. Generation times of three different B. divergens strains were then determined by the protocol described here and varied between 8 h 36 min and 13 h 8 min.

  7. The role of self-reported impulsivity and reward sensitivity versus neurocognitive measures of disinhibition and decision making in the prediction of relapse in pathological gamblers

    Goudriaan, A.E.; Oosterlaan, J.; de Beurs, E.; van den Brink, W.

    2008-01-01

    Background: Disinhibition and decision-making skills play an important role in theories on the cause and outcome of addictive behaviors such as substance use disorders and pathological gambling. In recent studies, both disinhibition and disadvantageous decision-making strategies, as measured by neurocognitive tests, have been found to influence the course of substance use disorders. Research on factors affecting relapse in pathological gambling is scarce. Method: This study investigated the e...

  8. How the risky features of previous selection affect subsequent decision-making: evidence from behavioral and fMRI measures.

    Dong, Guangheng; Zhang, Yifen; Xu, Jiaojing; Lin, Xiao; Du, Xiaoxia

    2015-01-01

    Human decision making is rarely conducted in temporal isolation. It is often biased and affected by environmental variables, particularly prior selections. In this study, we used a task that simulates a real gambling process to explore the effect of the risky features of a previous selection on subsequent decision making. Compared with decision making after an advantageous risk-taking situation (Risk_Adv), that after a disadvantageous risk-taking situation (Risk_Disadv) is associated with a longer response time (RT, the time spent in making decisions) and higher brain activations in the caudate and the dorsolateral prefrontal cortex (DLPFC). Compared with decisions after Risk_Adv, those after Risk_Disadv in loss trials are associated with higher brain activations in the left superior temporal gyrus (STG) and the precuneus. Brain activity and relevant RTs significantly correlated. Overall, people who experience disadvantageous risk-taking selections tend to focus on current decision making and engage cognitive endeavors in value evaluation and in the regulation of their risk-taking behaviors during decision making.

  9. PCA-based algorithm for calibration of spectrophotometric analysers of food

    Morawski, Roman Z; Miekina, Andrzej

    2013-01-01

    Spectrophotometric analysers of food, being instruments for determination of the composition of food products and ingredients, are today of growing importance for food industry, as well as for food distributors and consumers. Their metrological performance significantly depends of the numerical performance of available means for spectrophotometric data processing; in particular – the means for calibration of analysers. In this paper, a new algorithm for this purpose is proposed, viz. the algorithm using principal components analysis (PCA). It is almost as efficient as PLS-based algorithms of calibration, but much simpler

  10. UV Spectrophotometric Method for Determination of Cinitapride in Pure and its Solid Dosage Form

    B. Thangabalan

    2009-01-01

    Full Text Available A new, rapid, precise, accurate and sensitive analytical method was developed for the UV spectrophotometric assay of cinitapride (CTP. The drug obeyed the Beer's law and showed good correlation. It showed absorption maxima at 260 nm in methanol. The linearity was observed between 5-40 µg mL-1. The results of analysis were validated by recovery studies. The recovery was more than 99%. The proposed method is the only method available for spectrophotometric determination of the drug. It is simple, precise, sensitive and reproducible and can be used for the routine quality control testing of the marketed formulations.

  11. Spectrophotometric determination of dopaminergic drugs used for Parkinson's disease, cabergoline and ropinirole, in pharmaceutical preparations.

    Onal, Armağan; Cağlar, Sena

    2007-04-01

    Simple and reproducible spectrophotometric methods have been developed for determination of dopaminergic drugs used for Parkinson's disease, cabergoline (CAB) and ropinirole hydrochloride (ROP), in pharmaceutical preparations. The methods are based on the reactions between the studied drug substances and ion-pair agents [methyl orange (MO), bromocresol green (BCG) and bromophenol blue (BPB)] producing yellow colored ion-pair complexes in acidic buffers, after extracting in dichloromethane, which are spectrophotometrically determined at the appropriate wavelength of ion-pair complexes. Beer's law was obeyed within the concentration range from 1.0 to 35 microg ml(-1). The developed methods were applied successfully for the determination of these drugs in tablets.

  12. Application of spectrophotometric, densitometric, and HPLC techniques as stability indicating methods for determination of Zaleplon in pharmaceutical preparations

    Metwally, Fadia H.; Abdelkawy, M.; Abdelwahab, Nada S.

    2007-12-01

    Spectrophotometric, spectrodensitometric and HPLC are stability indicating methods described for determination of Zaleplon in pure and dosage forms. As Zaleplon is easily degradable, the proposed techniques in this manuscript are adopted for its determination in presence of its alkaline degradation product, namely N-[4-(3-cyano-pyrazolo[1,5a]pyridin-7-yl)-phenyl]- N-ethyl-acetamide. These approaches are successfully applied to quantify Zaleplon using the information included in the absorption spectra of appropriate solutions. The second derivative (D 2) spectrophotometric method, allows determination of Zaleplon without interference of its degradate at 235.2 nm using 0.01N HCl as a solvent with obedience to Beer's law over a concentration range of 1-10 μg ml -1 with mean percentage recovery 100.24 ± 0.86%. The first derivative of the ratio spectra ( 1DD) based on the simultaneous use of ( 1DD) and measurement at 241.8 nm using the same solvent and over the same concentration range as (D 2) spectrophotometric method, with mean percentage recovery 99.9 ± 1.07%. The spectrodensitometric analysis allows the separation and quantitation of Zaleplon from its degradate on silica gel plates using chloroform:acetone:ammonia solution (9:1:0.2 by volume) as a mobile phase. This method depends on quantitave densitometric evaluation of thin layer chromatogram of Zaleplon at 338 nm over a concentration range of 0.2-1 μg band -1, with mean percentage recovery 99.73 ± 1.35. Also a reversed-phase liquid chromatographic method using 5-C8 (22 cm × 4.6 mm i.d. 5 μm particle size) column was described and validated for quantitation of Zaleplon using acetonitrile:deionised water (35:65, v/v) as a mobile phase using Paracetamol as internal standard and a flow rate of 1.5 ml min -1 with UV detection of the effluent at 232 nm at ambient temperature over a concentration range of 2-20 μg ml -1 with mean percentage recovery 100.19 ± 1.15%. The insignificance difference of the proposed

  13. Spectrophotometric determination of boron by solvent extraction with hydrobenzoin and crystal violet

    Sato, Shigeya; Uchikawa, Sumio

    1982-01-01

    A highly sensitive and simple method for the spectrophotometric determination of boron was developed. Boron was found to react with hydrobenzoin in weak alkaline medium to form a complex anion extractable into benzene with crystal violet, and the measurement of the absorbance of crystal violet in the extract at 600 nm enabled the determination of boron indirectly. The recommended procedure is as follows: Take an aliquot of the boron solution (2.0 x 10 - 4 mol l - 1 ) into a 10-ml test tube. Add 1 ml of carbonate buffer solution (pH 9.4) and 0.25 ml of crystal violet solution (1.0 x 10 - 2 mol l - 1 ), and dilute the mixed solution to 4 ml with deionized water. Shake the solution with 4 ml of benzene solution containing hydrobenzoin (2.0 x 10 - 2 mol l - 1 ) for 2 min. Measure the absorbance of the organic phase at 600 nm using a 10-mm glass cell against benzene. The calibration curve obeyed Beer's law on the concentration range from 2.5 x 10 - 6 mol l - 1 to 2.5 x 10 - 5 mol l - 1 of boron, and the apparent molar absorptivity was 3.0 x 10 4 l mol - 1 cm - 1 at 20 0 C. It was found that many kinds of co-existing ions interfered with the determination. However, this method was applicable to the determination of boron in sea water when chloride ion and cations such as Ca(II) and Mg(II) were previously eliminated by treating the sample solution with Ag 2 O and cation exchanger resin. The proposed method is a very simple and rapid one, because this method does not require apparatus other than common laboratories and the evaporation to dryness of sample or removal of the excess of reagent. (author)

  14. Reaction of uranium (IV) with xenon difluoride by chemiluminescence, spectrophotometric, and spectrofluorimetric methods

    Mamykin, A.V.; Kazakov, V.P.

    1988-07-01

    A study is made of the kinetics of the chemiluminescent reaction of oxidation of uranium (IV) by xenon difluoride in 1M HClO/sub 4/ U/sup 4 +/ + XeF/sub 2/ ..-->.. UO/sub 2//sup 2 +/ = h/eta/. The optical density D and the intensity of the photoluminescence of the solution I/sub PL/ were measured in parallel with recording of the luminescence intensity I/sub CL/. I/sub CL/ attains a maximum value some time after the beginning of the reaction, after which it decays exponentially. On the kinetic curves of the time dependence of D and I/sub PL/ an induction period is observed, the extent of which depends on concentrations of reagents and temperature of the solution. The maximum of I/sub CL/ coincides with the end of the induction period if the measurements are carried out under identical conditions. The rate of the reaction after the induction period is described by a first order equation in U/sup (IV)/. The rate constants of the reaction, obtained by chemiluminescence, spectrophotometric, and spectrofluorimetric methods, have close values 2.0 +- 0.4, 1.8 +- 0.3, and 2.1 +- 0.3 sec/sup /minus/1/ x 10/sup 2/, respectively. On the basis of the results obtained, we conclude that the stages of formation of UO/sub 2//sup 2 +/ and of chemiluminescence coincide, i.e., formation of the excited state (UD/sub 2//sup 2 +/) and of chemiluminescence coincide, i.e., formation of the excited state (UD/sub 2//sup 2 +/)* takes place during the reaction. It is proposed and experimentally verified that the reaction passes through an intermediate stage of formation of uranyl ion UO/sub 2//sup +/.

  15. Analysis on the Decision Making on Nuclear Material Measurements for Safeguards Efficiency and Effectiveness on Research and Power Reactors

    Petit Wiringgalih; Basuki Wibowo

    2004-01-01

    This paper discusses three options in quantifying nuclear materials, ie. status quo, mobile unit measurement and centralised measurement. These three options are compared based on their safeguards effectiveness, timeline / efficiency, cost and safety aspects. Status quo measurement relies unverified estimation on nuclear materials, mobile unit measurement utilise NDA technique in order to obtain more accurate result while centralised measurement system transfers all measurements to another facility which posses more sophisticated equipment. Each of these three measurement options posesses relative advantages and disadvantages over the others. Status quo quantification is easy to perform but entails high inaccuracy. Mobile unit quantification is probably the best option, but it yields higher cost and radiation doses to workers. Centralised measurement facility is difficult to realise since the radioactive materials have to be coverted to their stable form. (author)

  16. Multicomponent kinetic spectrophotometric determination of pefloxacin and norfloxacin in pharmaceutical preparations and human plasma samples with the aid of chemometrics

    Ni, Yongnian; Wang, Yong; Kokot, Serge

    2008-10-01

    A spectrophotometric method for the simultaneous determination of the important pharmaceuticals, pefloxacin and its structurally similar metabolite, norfloxacin, is described for the first time. The analysis is based on the monitoring of a kinetic spectrophotometric reaction of the two analytes with potassium permanganate as the oxidant. The measurement of the reaction process followed the absorbance decrease of potassium permanganate at 526 nm, and the accompanying increase of the product, potassium manganate, at 608 nm. It was essential to use multivariate calibrations to overcome severe spectral overlaps and similarities in reaction kinetics. Calibration curves for the individual analytes showed linear relationships over the concentration ranges of 1.0-11.5 mg L -1 at 526 and 608 nm for pefloxacin, and 0.15-1.8 mg L -1 at 526 and 608 nm for norfloxacin. Various multivariate calibration models were applied, at the two analytical wavelengths, for the simultaneous prediction of the two analytes including classical least squares (CLS), principal component regression (PCR), partial least squares (PLS), radial basis function-artificial neural network (RBF-ANN) and principal component-radial basis function-artificial neural network (PC-RBF-ANN). PLS and PC-RBF-ANN calibrations with the data collected at 526 nm, were the preferred methods—%RPE T ˜ 5, and LODs for pefloxacin and norfloxacin of 0.36 and 0.06 mg L -1, respectively. Then, the proposed method was applied successfully for the simultaneous determination of pefloxacin and norfloxacin present in pharmaceutical and human plasma samples. The results compared well with those from the alternative analysis by HPLC.

  17. Oxygen consumption in Plasmodium berghei-infected murine red cells: a direct spectrophotometric assay in intact erythrocytes.

    Deslauriers, R; Moffatt, D J; Smith, I C

    1986-05-29

    A spectrophotometric assay has been devised to measure oxygen consumption non-invasively in intact murine red cells parasitized by Plasmodium berghei. The method uses oxyhemoglobin in the erythrocytes both as a source of oxygen and as an indicator of oxygen consumption. Spectra of intact cells show broad peaks and sloping baselines due to light-scattering. In order to ascertain the number of varying components in the 370-450 nm range, the resolution of the spectra was enhanced using Fourier transforms of the frequency domain spectra. Calculation of oxygen consumption was carried out for two-component systems (oxyhemoglobin, deoxyhemoglobin) using absorbances at 415 and 431 nm. Samples prepared from highly parasitized mice (greater than 80% parasitemia, 5% hematocrit) showed oxygen consumption rates of (4-8) X 10(-8) microliter/cell per h. This rate was not attributable to the presence of white cells or reticulocytes. The rate of oxygen consumption in the erythrocytes is shown to be modulated by various agents: the respiratory inhibitors NaN3 and KCN (1 mM) reduced oxygen consumption 2-3-fold; salicylhydroxamic acid (2.5 mM) caused a 20% reduction in rate and 10 mM NaN3, completely blocked deoxygenation. Antimalarial drugs and metal-chelating agents were also tested. Chloroquine, EDTA and desferal (desferoxamine mesylate) did not decrease the deoxygenation rate of hemoglobin in parasitized cells. Quinacrine, quinine and primaquine reduced the rate of formation of deoxyhemoglobin but also produced substantial quantities of methemoglobin. The lipophilic chelator, 5-hydroxyquinoline, decreased the rate of deoxygenation one-third. The spectrophotometric assay provides a convenient means to monitor oxygen consumption in parasitized red cells, to test the effects of various agents thereon, and potentially to explore possible mechanisms for oxygen utilization.

  18. Stability indicating spectrophotometric and spectrodensitometric methods for the determination of diatrizoate sodium in presence of its degradation product

    Abd El-Rahman, Mohamed K.; Riad, Safaa M.; Abdel Gawad, Sherif A.; Fawaz, Esraa M.; Shehata, Mostafa A.

    2015-02-01

    Three sensitive, selective, and precise stability indicating methods for the determination of the X-ray contrast agent, diatrizoate sodium (DTA), in the presence of its acidic degradation product (highly cytotoxic 3,5 diamino metabolite) and in pharmaceutical formulation were developed and validated. The first method is a first derivative (D1) spectrophotometric one, which allows the determination of DTA in the presence of its degradate at 231.2 nm (corresponding to zero crossing of the degradate) over a concentration range of 2-24 μg/mL with mean percentage recovery 99.95 ± 0.97%. The second method is the first derivative of the ratio spectra (DD1) by measuring the peak amplitude at 227 nm over the same concentration range as D1 spectrophotometric method, with mean percentage recovery 99.99 ± 1.15%. The third method is a TLC-densitometric one, where DTA was separated from its degradate on silica gel plates using chloroform:methanol:ammonium hydroxide (20:10:2 by volume) as a developing system. This method depends on quantitative densitometric evaluation of thin layer chromatogram of DTA at 238 nm over a concentration range of 4-20 μg/spot, with mean percentage recovery 99.88 ± 0.89%. The selectivity of the proposed methods was tested using laboratory-prepared mixtures. The proposed methods have been successfully applied to the analysis of DTA in pharmaceutical dosage forms without interference from other dosage form additives. The results were statistically compared with the official US pharmacopeial method. No significant difference for either accuracy or precision was observed.

  19. Spectrophotometric and chromatographic determination of insensitive energetic materials: HNS and NTO, in the presence of sensitive nitro-explosives.

    Can, Ziya; Uzer, Ayşem; Tekdemir, Yasemin; Erçağ, Erol; Türker, Lemi; Apak, Reşat

    2012-02-15

    As there are no molecular spectroscopic determination methods for the most widely used insensitive energetic materials, 2,2',4,4',6,6'-hexanitrostilbene (HNS) and 3-nitro-1,2,4-triazole-5-one (NTO), in the presence of sensitive nitro-explosives, two novel spectrophotometric methods were developed. For HNS and TNT mixtures, both analytes react with dicyclohexylamine (DCHA) forming different colored charge-transfer complexes, which can be resolved by derivative spectroscopy. The spectrophotometric method for NTO measures the 416-nm absorbance of its yellow-colored Na(+)NTO(-) salt formed with NaOH. TNT, if present, is pre-extracted into IBMK as its Meisenheimer anion forming an ion-pair with the cationic surfactant cetyl pyridinium (CP(+)) in alkaline medium, whereas the unextracted NTO is determined in the aqueous phase. The molar absorptivity (ε, L mol(-1)cm(-1)) and limit of quantification (LOQ, mg L(-1)) are as follows: for HNS, ε=2.75 × 10(4) and LOQ=0.48 (in admixture with TNT); for NTO, ε=6.83 × 10(3) and LOQ=0.73. These methods were not affected from nitramines and nitrate esters in synthetic mixtures or composite explosives. The developed methods were statistically validated against HPLC, and the existing chromatographic method was modified so as to enable NTO determination in the presence of TNT. These simple, low-cost, and versatile methods can be used in criminology, remediation/monitoring of contaminated sites, and kinetic stability modeling of munitions containing desensitized energetic materials. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Decision making under risk : a study of models and measurement procedures with special reference to the farmer's marketing behavior

    Smidts, A.

    1990-01-01

    The objectives of the study were: a) to review, discuss and test a number of theories on individual decision making under risk; much attention is specifically given to the definition and empirical testing of the concept of relative risk attitude, b) to investigate in a large scale survey

  1. Decision making under risk. A study of models and measurement procedures with special reference to the farmers' marketing behavior

    A. Smidts (Ale)

    1990-01-01

    textabstractThe objectives of the study were: a) to review, discuss and test a number of theories on individual decision making under risk; much attention is specifically given to the definition and empirical testing of the concept of relative risk attitude, b) to investigate in a large scale survey

  2. Selective determination of cyanide complexes of copper, zinc and cadmium in electrolytes by spectrophotometric titration

    Kuznetsov, V.V.; Korchagina, O.A.; Samorukova, O.L.

    1986-01-01

    Selective, sensitive and rapid method for determining Cd, Zn, Cu and their mixtures in cyanide electrolytes of galvanic bathes has been developed. Analysis is performed by means of indicator spectrophotometric titration with barium and strontium salts of cadmium cyanide complexes in organic-aqueous solvents

  3. Determination of cyanide by an indirect spectrophotometric method using 5-Br-PADAP.

    Fu-Sheng, W; Yu-Qin, L; Fang, Y; Nai-Kui, S

    1981-09-01

    Complexation of Ni(2+) with cyanide inhibits its colour reaction with 5-Br-PADAP and this reaction is used in the spectrophotometric determination of cyanide at the ug level. Cyanide in industrial waste waters is determined after an initial transfer as hydrogen cyanide from the sample into sodium hydroxide solution with a stream of air.

  4. Spectrophotometric investigation into iodine-electron donor systems at low temperature

    Gorodyskij, V.A.; Morachevskij, A.A.

    1978-01-01

    Iodine-sec. butanol (n-donor) and iodine - hexene - 1 (π-donor) have been investigated for the first time by the spectrophotometric method in the wide temeprature range (77-293 K). The existence of complexes with a charge transfer of the type, which is characterized by the long-wave absorption band in electron spectra, is determined in the systems

  5. Spectrophotometric determination of boron in water with prior distillation and hydrolysis of the methyl borate

    Monzo, J.; Pomares, F.; Guardia, M. de la

    1988-01-01

    A procedure for the determination of boron in irrigation waters is proposed, involving the prior distillation and hydrolysis of methyl borate and subsequent spectrophotometric determination with azomethine-H. The selectivity is better than that of the direct analysis method. (author)

  6. Using Spectrophotometric Titrations To Characterize Humic Acid Reactivity at Environmental Concentrations

    Janot, N.; Benedetti, M. F. [Univ Paris Diderot, Lab Geochim Eaux, UMR CNRS 7154, IPGP, F-75025 Paris 13 (France); Janot, N.; Reiller, P. E. [CE Saclay, CEA DEN DANS DPC SECR, Lab Speciat Radionucleides and Mol, F-91191 Gif Sur Yvette (France); Korshin, G. V. [Univ Washington, Dept Civil and Environm Engn, Seattle, WA 98195 (United States)

    2010-07-01

    Potentiometric titration is a common method to characterize dissolved organic matter (DOM) reactivity. Because of the sensitivity of pH electrodes, it is necessary to work with very high DOM ({>=}1 g/L) concentrations that are unrealistic compared to those found in natural waters (0. 1 to 100 mg/L). To obtain proton binding data for concentrations closer to environmental values, spectroscopic titration methodology is a viable alternative to traditional potentiometric titrations. Spectrophotometric titrations and UV visible spectra of a diluted solution of purified Aldrich humic acid (5 mg(DOC)/L) are used to estimate changes in proton binding moieties as function of pH and ionic strength after calculation of differential absorbance spectra variations. After electrostatic correction of spectrophotometric data, there is a linear operational correlation between spectrophotometric and potentiometric data which can be used as a transfer function between the two properties. Spectrophotometric titrations are then used to determine the changes of humic acid protonation after adsorption onto alpha-alumina. (authors)

  7. Liquid chromatographic and spectrophotometric methods for the determination of erythromycin stearate and trimethoprim in tablets

    Sonia T. Hassib

    2011-12-01

    Full Text Available Simple, accurate and precise reversed-phase liquid chromatographic (LC and spectrophotometric methods have been developed and validated for the determination of erythromycin stearate (ERS and trimethoprim (TMP in mixture. In LC method, chromatographic separation was achieved on a Symmetry® Waters C18 column (150 × 4.6 mm, 5 μm based on isocratic elution using a mobile phase consisting of potassium dihydrogen phosphate buffer pH (9:acetonitrile:water (25:100:50, v/v/v at a flow rate of 1.6 ml min−1 with UV detection at 210 nm for ERS and 280 nm for TMP. Besides, two spectrophotometric methods were applied after reaction with perchloric acid (12 M which gives a colored product with ERS. Then, the spectral interference between the colored product of ERS and TMP was resolved by either ratio spectra derivative spectrophotometry in the first spectrophotometric method or chemometric techniques, namely classical least-squares (CLS, principal component regression (PCR and partial least-squares regression (PLS in the second spectrophotometric method. The results were statistically compared using one-way analysis of variance (ANOVA. The methods developed were satisfactorily applied to the analysis of the pharmaceutical preparation containing the two drugs and proved to be specific and accurate for the quality control of the cited drugs in pharmaceutical dosage forms.

  8. Using Spectrophotometric Titrations To Characterize Humic Acid Reactivity at Environmental Concentrations

    Janot, N.; Benedetti, M. F.; Janot, N.; Reiller, P. E.; Korshin, G. V.

    2010-01-01

    Potentiometric titration is a common method to characterize dissolved organic matter (DOM) reactivity. Because of the sensitivity of pH electrodes, it is necessary to work with very high DOM (≥1 g/L) concentrations that are unrealistic compared to those found in natural waters (0. 1 to 100 mg/L). To obtain proton binding data for concentrations closer to environmental values, spectroscopic titration methodology is a viable alternative to traditional potentiometric titrations. Spectrophotometric titrations and UV visible spectra of a diluted solution of purified Aldrich humic acid (5 mg(DOC)/L) are used to estimate changes in proton binding moieties as function of pH and ionic strength after calculation of differential absorbance spectra variations. After electrostatic correction of spectrophotometric data, there is a linear operational correlation between spectrophotometric and potentiometric data which can be used as a transfer function between the two properties. Spectrophotometric titrations are then used to determine the changes of humic acid protonation after adsorption onto alpha-alumina. (authors)

  9. Strengthening the Assessment Trajectory: Engaging Educators in the Policy Process. Making a Measurable Difference: Case Studies from the High-Quality Assessment Project

    McClellan, Catherine; Snyder, Rebecca; Woods-Murphy, Maryann; Basset, Katherine

    2018-01-01

    Great teachers recognize great assessments. As policy and education leaders work to make sure state tests are measuring the problem-solving, writing, and critical-thinking skills students need for success, they should convene and rely on teachers to review test quality and help answer the question: Do the questions on our state test reflect…

  10. Novel Spectrophotometric Methods for Determination of Salicylamide and Ascorbic acid in their binary mixture

    Ali, N.W.; Zaazaa, H.E.S.; Abdelrahman, M.M.

    2014-01-01

    Simple, selective and precise four spectrophotometric methods were developed and validated for quantitative determination of Salicylamide (SAD) and Ascorbic acid (ASC, Vitamin C) in their binary mixture. Method A is Area under curve spectrophotometry, in which the area under curve in the wavelength ranges 225-245 nm and 265-285 nm were selected for determination of SAD and ASC. Method B is based on dual wavelength spectrophotometry, where ASC can be determined by difference in absorbance at 249.8 and 285.8 nm. On the same way; SAD is measured by difference in absorbance at 240.4 and 286.4 nm. Method C utilizes isoabsorptive point spectrophotometry where total concentration of SAD and ASC was calculated at their isoabsorptive points at 246.4 and 287 nm, while SAD concentration alone can be determined by first derivative spectrophotometry (1D) at 315.4 nm, then ASC concentration can be determined by subtraction. Method D is ratio subtraction spectrophotometry, where ASC can be determined by dividing the spectrum of the mixture by the spectrum of the SAD (as a divisor) followed by subtracting the constant absorbance value of the plateau region, then finally multiplying the obtained spectrum by the spectrum of the divisor. The developed methods have been successfully applied for determination of the studied drugs in different laboratory prepared mixtures and in their pharmaceutical formulation. Statistical comparison between the results obtained by applying the proposed methods and the reported HPLC method was done, and it was found that there was no significant difference between them regarding both accuracy and precision. (author)

  11. Comparison of Spectrophotometric Methods for the Determination of Copper in Sugar Cane Spirit.

    Soares, Sarah Adriana R; Costa, Silvânio Silvério L; Araujo, Rennan Geovanny O; Teixeira, Leonardo Sena Gomes; Dantas, Alailson Falcão

    2018-05-01

    Three spectrophotometric methods were developed for the determination of copper (Cu) in sugar cane spirit using the chromogenic reagents neocuproine, cuprizone, and bathocuproine. Experimental conditions, such as reagent concentration, reducer concentration, pH, buffer concentration, the order of addition of reagents, and the stability of the complexes, were optimized. The work range was established from 1.0 to 10.0 µg/mL, with correlation coefficients of >0.999 for all three optimized methods. The methods were evaluated regarding accuracy by addition and recovery tests at five concentration levels, and the obtained recoveries ranged from 91 to 105% (n = 3). Precision was expressed as RSD (relative standard deviation), with values ranging from 0.01 to 0.17% (n = 10). The method using the chromogenic reagent cuprizone presented the greatest molar absorptivity, followed by bathocuproine and neocuproine. The methods were applied for the determination of Cu in sugar cane spirit, and the results were compared with a reference method by flame atomic absorption spectrometry (FAAS). Calibration curve solutions for FAAS analysis were prepared in a 40% (v/v) alcohol medium in a range of concentrations from 0.5 up to 5 µg/mL. Measurements for Cu determination were carried out at a wavelength of 324.7 nm. The concentrations obtained for Cu in sugar cane spirit samples from Brazil were between 1.99 and 12.63 µg/mL, and about 75% of the samples presented Cu concentrations above the limit established by Brazilian legislation (5.0 µg/mL or 5.0 mg/L).

  12. Spectrophotometric method for quantitative determination of triclabendazole in bulk and pharmaceutical

    Alankar Shrivastava

    2011-01-01

    Full Text Available Background: Triclabendazole (TCBZ, 6-chloro-5(2-3 dichlorophenoxy-2-methyl thio-benzimidazole, an halogenated benzimidazole (BZD thiol derivative, shows high efficacy against both the immature and mature stages of Fasciola hepatica in sheep and cattle, which is a differential feature compared to other available trematodicidal drugs. As a consequence of its excellent activity against the liver fluke, it has been extensively used and this has inevitably promoted the selection of TCBZ-resistant populations, which is now a worrying problem in several areas of the world. We propose simple ultraviolet spectrophotometric method for the estimation of triclabendazole in 0.1 methanolic HCl for the estimation of the drug. Method was validated as per ICH guidelines. Materials and Methods: Spectral absorbance measurements were made on Shimadzu UV-1800 with 10 mm matched quartz cells and dilutions were made in 0.1 M methanolic HCl. Results: The LOD and LOQ of triclabendazole at 305 nm were found to be 0.068434 and 2.73×10-4 μg/ml respectively. The calibration was linear in the range of 1-10 μg/ml. Analytical parameters such as stability, selectivity, accuracy, and precision have been established for the method in Endex and Fasinex tablets and evaluated statistically to assess the application of the method. Conclusion: Method passes all parameters with in desirable limits and found to be simple, stable, sensitive, reproducible, and accurate for the routine analysis of the drug in pharmaceutical formulations and in pharmaceutical investigations involving triclabendazole.

  13. Spectrophotometric analysis of discoloration and internal bleaching after use of different antibiotic pastes.

    Fundaoğlu Küçükekenci, Funda; Çakici, Fatih; Küçükekenci, Ahmet Serkan

    2018-04-14

    To investigate teeth's antibiotic-induced color differences after bleaching using two different techniques. One hundred twenty extracted maxillar human incisors were examined. The specimens were randomly divided into six groups, each receiving one of six antibiotic paste fillings: (1) triple antibiotic paste (TAP) with minocycline, (2) double antibiotic paste (DAP), (3) TAP with amoxicillin, (4) TAP with cefaclor, (5) TAP with doxycycline, and (6) no filling (control group). Spectrophotometric measurements were obtained at baseline and then during the first, second, and third weeks after paste placement. The specimens discolored by antibiotics pastes were randomly divided into two subgroups: (1) internal bleaching with hydrogen peroxide (H 2 O 2) and (2) internal bleaching with H 2 O 2 plus Nd-YAG laser irradiation. The ∆E value was calculated and analyzed using a two-way analysis of variance and post-hoc Tukey's test (α = 0.05). The ∆E for all groups showed color differences exceeding the perceptibility threshold (∆E ˃ 3.7) at all time points except in the control and DAP groups. Minocycline-induced TAP showed the most severe coronal discoloration (32.42). When the ∆E was examined, thermo/photo bleaching (22.01 ± 8.23) caused more bleaching than walking bleaching (19.73 ± 5.73) at every time point (P = 0.19). No group returned to the original color after bleaching (P bleaching with Nd-YAG laser can be useful for bleaching/removing this discoloration. For clinically successful final appearances, understanding the effects of bleaching procedures on antibiotic paste discoloration is important.

  14. Chromium speciation in environmental samples using a solid phase spectrophotometric method

    Amin, Alaa S.; Kassem, Mohammed A.

    2012-10-01

    A solid phase extraction technique is proposed for preconcentration and speciation of chromium in natural waters using spectrophotometric analysis. The procedure is based on sorption of chromium(III) as 4-(2-benzothiazolylazo)2,2'-biphenyldiol complex on dextran-type anion-exchange gel (Sephadex DEAE A-25). After reduction of Cr(VI) by 0.5 ml of 96% concentrated H2SO4 and ethanol, the system was applied to the total chromium. The concentration of Cr(VI) was calculated as the difference between the total Cr and the Cr(III) content. The influences of some analytical parameters such as: pH of the aqueous solution, amounts of 4-(2-benzothiazolylazo)2,2'-biphenyldiol (BTABD), and sample volumes were investigated. The absorbance of the gel, at 628 and 750 nm, packed in a 1.0 mm cell, is measured directly. The molar absorptivities were found to be 2.11 × 107 and 3.90 × 107 L mol-1 cm-1 for 500 and 1000 ml, respectively. Calibration is linear over the range 0.05-1.45 μg L-1 with RSD of <1.85% (n = 8.0). Using 35 mg exchanger, the detection and quantification limits were 13 and 44 ng L-1 for 500 ml sample, whereas for 1000 ml sample were 8.0 and 27 ng L-1, respectively. Increasing the sample volume can enhance the sensitivity. No considerable interferences have been observed from other investigated anions and cations on the chromium speciation. The proposed method was applied to the speciation of chromium in natural waters and total chromium preconcentration in microwave digested tobacco, coffee, tea, and soil samples. The results were simultaneously compared with those obtained using an ET AAS method, whereby the validity of the method has been tested.

  15. Optimization and validation of spectrophotometric methods for determination of finasteride in dosage and biological forms

    Amin, Alaa S.; Kassem, Mohammed A.

    2012-01-01

    Aim and Background: Three simple, accurate and sensitive spectrophotometric methods for the determination of finasteride in pure, dosage and biological forms, and in the presence of its oxidative degradates were developed. Materials and Methods: These methods are indirect, involve the addition of excess oxidant potassium permanganate for method A; cerric sulfate [Ce(SO4)2] for methods B; and N-bromosuccinimide (NBS) for method C of known concentration in acid medium to finasteride, and the determination of the unreacted oxidant by measurement of the decrease in absorbance of methylene blue for method A, chromotrope 2R for method B, and amaranth for method C at a suitable maximum wavelength, λmax: 663, 528, and 520 nm, for the three methods, respectively. The reaction conditions for each method were optimized. Results: Regression analysis of the Beer plots showed good correlation in the concentration ranges of 0.12–3.84 μg mL–1 for method A, and 0.12–3.28 μg mL–1 for method B and 0.14 – 3.56 μg mL–1 for method C. The apparent molar absorptivity, Sandell sensitivity, detection and quantification limits were evaluated. The stoichiometric ratio between the finasteride and the oxidant was estimated. The validity of the proposed methods was tested by analyzing dosage forms and biological samples containing finasteride with relative standard deviation ≤ 0.95. Conclusion: The proposed methods could successfully determine the studied drug with varying excess of its oxidative degradation products, with recovery between 99.0 and 101.4, 99.2 and 101.6, and 99.6 and 101.0% for methods A, B, and C, respectively. PMID:23781478

  16. Spectrophotometric determination of yttrium with 2-(2-thiazolylazo)-5-dimethylaminophenol

    Tsurumi, Chikao; Furuya, Keiichi.

    1975-01-01

    Spectrophotometric determination of small amounts of yttrium with 2-(2-thiazolylazo)-5-dimethylaminophenol (TAM) in the presence of zephiramine was investigated. The recommended procedures were as follows; 2.0 ml of water, 7.0 ml of TAM-methanolic solution (2x10 -4 mol/l) and 2.0 ml of zephiramine-aqueous solution (1x10 -2 mol/l) were added to a solution containing less than 35 μg of yttrium and its pH was adjusted to 8.0 with 0.1 mol/l ammonium chloride-0.1 mol/l ammonium hydroxide solution. The solution was transferred to a 25 ml volumetric flask and diluted to the mark with water. After 20 minutes, the absorbance at 575 nm against a reagent blank was measured. The color of yttrium-TAM complex is reddish-violet in the presence of zephiramine and is stable for 90 minutes after color development. The yttrium-TAM complex shows an absorption maximum at 575 nm. The absorbance at 575 nm is constant in a pH range from 7.5 to 8.3. The molar extinction coefficient at this wavelength is 7.2x10 4 l.mol -1 .cm -1 . The band obeys Beer's law up to the concentration of 1.4 μg/ml of yttrium. The molar ratio of yttrium to TAM in the complex is 1 : 2. A number of ions interfere with the determination can be masked by the addition of various masking agents and removed in terms of trioctylamine-xylene extraction. Manganese, tantalum, tin(II), citrate and tartrate ions interfere with the determination. (auth.)

  17. Can we measure patients' perception during dental impressions? The Burdens in Dental Impression-Making Questionnaire - BiDIM-Q.

    Tsirogiannis, Panagiotis; Neophytou, Sophia; Reul, Anika; Heydecke, Guido; Reissmann, Daniel R

    2017-01-01

    To develop a reliable and valid instrument for the comprehensive assessment of patients' burdens during dental impression making, the Burdens in Dental Impression Making Questionnaire, BiDIM-Q. The item pool was generated in a convenience sample of 20 prosthodontic patients using semi-structured face-to-face interviews. The final instrument was tested in 145 consecutively recruited patients, and psychometric properties of the BiDIM-Q were determined. Four different impression materials were used according to the manufacturers' instructions and indications: alginate, c-silicone, polyvinylsiloxane, and polyether. The final BiDIM-Q consisting of 12 items showed sufficient reliability, indicated by Cronbach's alpha of .82 and an average inter-item correlation of .29. Validity was supported by Pearson correlation coefficients for the correlation between the instrument's total score with the patients' overall satisfaction rating (r=.63), and by the correlation matrix for the correlations of the patients' perceptions with the practitioners' satisfaction ratings. Overall, patient perceived burdens were low with highest burdens observed when using polyether in partially dentate patients for pick-up impressions, while lowest burdens were reported when using c-silicone for impressions of edentulous jaws. The BiDIM-Q is a reliable and valid tool for assessing patient-based process-related quality of care in dentistry allowing a deeper insight into patients' perspective during dental impression making. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  18. RDT&E Laboratory Capacity Utilization and Productivity Measurement Methods for Financial Decision-Making within DON

    Haupt, Jeffrey

    1998-01-01

    .... Industry capacity utilization and productivity measurement techniques and models were evaluated for their potential application to the Naval Air Warfare Center Aircraft Division (NAWCAD) RDT&E organization...

  19. The role of self-reported impulsivity and reward sensitivity versus neurocognitive measures of disinhibition and decision-making in the prediction of relapse in pathological gamblers.

    Goudriaan, A E; Oosterlaan, J; De Beurs, E; Van Den Brink, W

    2008-01-01

    Disinhibition and decision-making skills play an important role in theories on the cause and outcome of addictive behaviors such as substance use disorders and pathological gambling. In recent studies, both disinhibition and disadvantageous decision-making strategies, as measured by neurocognitive tests, have been found to influence the course of substance use disorders. Research on factors affecting relapse in pathological gambling is scarce. This study investigated the effect of both self-reported impulsivity and reward sensitivity, and neurocognitively assessed disinhibition and decision-making under conflicting contingencies, on relapse in a group of 46 pathological gamblers. Logistic regression analysis indicated that longer duration of the disorder and neurocognitive indicators of disinhibition (Stop Signal Reaction Time) and decision-making (Card Playing Task) were significant predictors of relapse (explaining 53% of the variance in relapse), whereas self-reported impulsivity and reward sensitivity did not significantly predict relapse. Overall classification accuracy was 76%, with a positive classification accuracy of 76% and a negative classification accuracy of 75%. Duration of the disorder and neurocognitive measures of disinhibition and decision-making are powerful predictors of relapse in pathological gambling. The results suggest that endophenotypical neurocognitive characteristics are more promising in the prediction of relapse in pathological gambling than phenotypical personality characteristics. Neurocognitive predictors may be useful to guide treatment planning of follow-up contacts and booster sessions.

  20. Decision making measured by the Iowa Gambling Task in alcohol use disorder and gambling disorder: a systematic review and meta-analysis.

    Kovács, Ildikó; Richman, Mara J; Janka, Zoltán; Maraz, Aniko; Andó, Bálint

    2017-12-01

    Gambling disorder (GD) and alcohol use disorder (AD) have similar features, such as elevated impulsivity and decision-making deficits, which are directly linked to relapse and poor therapeutic outcomes. Our aim was to assess decision-making characteristics in GD and AD patients compared to healthy controls (HC) based on one of the most frequently used measures of decision-making: the Iowa Gambling Task (IGT). In our systematic literature search of three databases, we identified 1198 empirical articles that mentioned decision-making deficits with the use of the IGT in patients diagnosed with either AD or GD. Possible effects were calculated using meta-analysis. In the end, 17 studies (including 1360 participants) were suitable for inclusion in the meta-analysis reporting data for 23 group contrasts. The random effects estimate indicated impaired IGT performance in both AD patients (N=500; d=-0.581, CI:-89.5decision-making deficit associated with addictive disorders, and that the deficit is more expressed in gambling disorder than in alcohol use disorder. Impaired decision-making plays an important part in poor therapeutic outcomes, thus provides a promising opportunity for cognitive intervention. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Valide measurements and quality consulting are the basis for making professional and proper decisions in radiation protection. A task for the NLWKN as a state authority for measurement

    Brueggemeyer, H.

    2016-01-01

    The NLWKN has as the official measuring point of the country Lower Saxony a long-standing experience in the measuring-technical in radiation protection and in the supply this information for different target groups. Some knowledge derived from this work is introduced here.

  2. Utilization of oxidation reactions for the spectrophotometric determination of captopril using brominating agents

    El-Didamony, Akram M.; Erfan, Eman A. H.

    2010-03-01

    Three simple, accurate and sensitive methods (A-C) for the spectrophotometric assay of captopril (CPL) in bulk drug, in dosage forms and in the presence of its oxidative degradates have been described. The methods are based on the bromination of captopril with a solution of excess brominating mixture in hydrochloric acid medium. After bromination, the excess brominating mixture is followed by the estimation of surplus bromine by three different reaction schemes. In the first method (A), the determination of the residual bromine is based on its ability to bleach the indigo carmine dye and measuring the absorbance at 610 nm. Method B, involves treating the unreacted bromine with a measured excess of iron(II) and the remaining iron(II) is complexed with 1,10-phenanthroline and the increase in absorbance is measured at 510 nm. In method (C), the surplus bromine is treated with excess of iron(II) and the resulting iron(III) is complexed with thiocyanate and the absorbance is measured at 478 nm. In all the methods, the amount of bromine reacted corresponds to the drug content. The different experimental parameters affecting the development and stability of the color are carefully studied and optimized. Beer's law is valid within a concentration range of 0.4-6.0, 0.4-2.8 and 1.2-4.8 μg mL -1 for methods A, B and C, respectively. The calculated apparent molar absorptivity was found to be 5.16 × 10 4, 9.95 × 10 4 and 1.74 × 10 5 L mol -1 cm -1, for methods A, B and C, respectively. Sandell's sensitivity, correlation coefficients, detection and quantification limits are also reported. No interference was observed from common additives found in pharmaceutical preparations. The proposed methods are successfully applied to the determination of CPL in the tablet formulations with mean recoveries of 99.94-100.11% and the results were statistically compared with those of a reference method by applying Student's t- and F-test.

  3. An expanded framework to define and measure shared decision-making in dialogue: A 'top-down' and 'bottom-up' approach.

    Callon, Wynne; Beach, Mary Catherine; Links, Anne R; Wasserman, Carly; Boss, Emily F

    2018-03-11

    We aimed to develop a comprehensive, descriptive framework to measure shared decision making (SDM) in clinical encounters. We combined a top-down (theoretical) approach with a bottom-up approach based on audio-recorded dialogue to identify all communication processes related to decision making. We coded 55 pediatric otolaryngology visits using the framework and report interrater reliability. We identified 14 clinician behaviors and 5 patient behaviors that have not been previously described, and developed a new SDM framework that is descriptive (what does happen) rather than normative (what should happen). Through the bottom-up approach we identified three broad domains not present in other SDM frameworks: socioemotional support, understandability of clinician dialogue, and recommendation-giving. We also specify the ways in which decision-making roles are assumed implicitly rather than discussed explicitly. Interrater reliability was >75% for 92% of the coded behaviors. This SDM framework allows for a more expansive understanding and analysis of how decision making takes place in clinical encounters, including new domains and behaviors not present in existing measures. We hope that this new framework will bring attention to a broader conception of SDM and allow researchers to further explore the new domains and behaviors identified. Copyright © 2018. Published by Elsevier B.V.

  4. Designing and making of a tool used for measurements by X fluorescence using HgI2 detectors

    Liu-Xu, X.

    1994-10-01

    A new measuring apparatus by X fluorescence based on a HgI 2 detector, operating at room temperature is presented. The principal properties of HgI 2 are outlined. A computer code designed for this apparatus is developed. Some experimental results are given to illustrate the performances of the device. (author). 67 refs., 117 figs., 7 tabs

  5. The Development of a New Inhibition Kinetic Spectrophotometric Method for the Determination of Phenylhydrazine Based on its Inhibitory Effect on Oxidation of Methyl Red by Bromate in Micellar Medium

    Mohsen Keyvanfard

    2010-01-01

    Full Text Available A new, simple, sensitive and selective kinetic spectrophotometric method was developed for the determination of trace amounts of phenylhydrazine over the range of 0.02-0.30 μg/mL. The method is based on the inhibitory effect of phenylhydrazine on the oxidation of methyl red by bromate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of methyl red at 518 nm with a fixed-time 0.5–2.0 min from initiation of the reaction..The relative standard deviation of 0.08 and 0.2 μg/mL phenylhydrazine was 1.7 and 2.4%, respectively. The method was applied to the determination of phenylhydrazine in water samples.

  6. Non-streaming high-efficiency perforated semiconductor neutron detectors, methods of making same and measuring wand and detector modules utilizing same

    McGregor, Douglas S.; Shultis, John K.; Rice, Blake B.; McNeil, Walter J.; Solomon, Clell J.; Patterson, Eric L.; Bellinger, Steven L.

    2010-12-21

    Non-streaming high-efficiency perforated semiconductor neutron detectors, method of making same and measuring wands and detector modules utilizing same are disclosed. The detectors have improved mechanical structure, flattened angular detector responses, and reduced leakage current. A plurality of such detectors can be assembled into imaging arrays, and can be used for neutron radiography, remote neutron sensing, cold neutron imaging, SNM monitoring, and various other applications.

  7. Analysis of Protein by Spectrophotometric and Computer Colour Based Intensity Method from Stem of Pea (Pisum sativum at Different Stages

    Afsheen Mushtaque Shah

    2010-12-01

    Full Text Available In this study proteins were analyzed from pea plants at three different growth stages of stem by spectrophotometric i.e Lowry and Bradford quantitative methods and computer colour intensity based method. Though Spectrophotometric methods are regarded as classical methods, we report an alternate computer based method which gave comparable results. Computer software was developed the for protein analysis which is easier, time and money saving method as compared to the classical methods.

  8. Does the Position or Contact Pressure of the Stethoscope Make Any Difference to Clinical Blood Pressure Measurements

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-01-01

    Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675

  9. Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements: an observational study.

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-12-01

    This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.

  10. Validation of SDM-Q-Doc Questionnaire to measure shared decision-making physician's perspective in oncology practice.

    Calderon, C; Ferrando, P J; Carmona-Bayonas, A; Lorenzo-Seva, U; Jara, C; Beato, C; García, T; Ramchandani, A; Castelo, B; Muñoz, M M; Garcia, S; Higuera, O; Mangas-Izquierdo, M; Jimenez-Fonseca, P

    2017-11-01

    The aim of this study was to analyze the psychometric properties of the Shared Decision-Making Questionnaire-Physician version (SDM-Q-Doc) in a sample of medical oncologists who provide adjuvant treatment to patients with non-metastatic resected cancer and the correlations between the total SDM-Q-Doc score and physician satisfaction with the information provided. Prospective, observational and multicenter study in which 32 medical oncologists and 520 patients were recruited. The psychometric properties, dimensionality, and factor structure of the SDM-Q-Doc were assessed. Exploratory factor analyses suggested that the most likely solution was two-dimensional, with two correlated factors: one factor regarding information and another one about treatment. Confirmatory factor analysis based on cross-validation showed that the fitted two-dimensional solution provided the best fit to the data. Reliability analyses revealed good accuracy for the derived scores, both total and sub-scale, with estimates ranging from 0.81 to 0.89. The results revealed significant correlations between the total SDM-Q-Doc score and physician satisfaction with the information provided (p Doc showed good psychometric properties and could be a helpful tool that examines physician's perspective of SDM and as an indicator of quality and satisfaction in patients with cancer.

  11. Use of classical criterions of a decision making for choice of measures on decrease of economic damage from nuclear and radiation accidents

    Rylov, M.I.; Kamynov, Sh.V.; Mozhaev, A.S.; Anisimov, N.A.; Nikitin, V.S.

    2004-01-01

    Application of classical criteria of decision making for choice of measures on the decrease of economic damage from possible nuclear and radiation accidents during spent fuel unloading from nuclear submarines and storage in the process of their utilization was demonstrated. Economic damage was chosen as optimization index, three versions of possible accidents and limited number of measures on the decrease of their effect were treated for illustration of the suggested approach. On the base of analysis of classical criteria the optimal strategy for decrease of economic damage was chosen [ru

  12. Determination of Modafinil in Tablet Formulation Using Three New Validated Spectrophotometric Methods

    Basniwal, P.K.; Jain, D.; Basniwal, P.K.

    2014-01-01

    In this study, three new UV spectrophotometric methods viz. linear regression equation (LRE), standard absorptivity (SA) and first order derivative (FOD) method were developed and validated for determination of modafinil in tablet form. The Beer-Lamberts law was obeyed as linear in the range of 10-50 μg/ mL and all the methods were validated for linearity, accuracy, precision and robustness. These methods were successfully applied for assay of modafinil drug content in tablets in the range of 100.20 - 100.42 %, 100.11 - 100.58 % and 100.25 - 100.34 %, respectively with acceptable standard deviation (less than two) for all the methods. The validated spectrophotometric methods may be successfully applied for assay, dissolution studies, bio-equivalence studies as well as routine analysis in pharmaceutical industries. (author)

  13. Complexation equilibria and spectrophotometric determination of iron(III) with 1-amino-4-hydroxyanthraquinone.

    Abu-Bakr, M S; Sedaira, H; Hashem, E Y

    1994-10-01

    The complex equilibria of iron(III) with 1-amino-4-hydroxyanthraquinone (AMHA) were studied spectrophotometrically in 40% (v/v) ethanol and an ionic strength of 0.1M (NaClO(4)). The complexation reactions were demonstrated and characterized using graphical logarithmic analysis of the absorbance-pH graphs. A simple, rapid, selective and sensitive method for the spectrophotometric determination of trace amounts of Fe(III) is developed based on the formation of Fe(AMHA) complex at pH 2.5 (lambda(max) = 640 nm, epsilon approximately = 2.1 x 10(4) L. mol(-1) . cm(-1)) in the presence of a large number of foreign ions. Interferences caused by palladium(II) was masked by the addition of cyanide ions. The method has been applied to the determination of iron in some synthetic samples and polymetallic iron ores.

  14. Spectrophotometric determination of uranium by previous extraction chromatography separation in polimetalic mineral, phosphorites and technological licours

    Moreno Bermudez, J.; Cabrera Quevedo, C.; Alfonso Mendez, L.; Rodriguez Aguilera, M.

    1994-01-01

    The development of an analytical procedure for spectrophotometric determination of uranium in polimetalic mineral, phosphorites and technological licours is described. The method is based on the previous separation of interfering elements by extraction chromatography and on spectrophotometric determination of uranium (IV) with arsenazo III in concentrated hydrochloric acid. Tributyl phosphate impregnate on politetrafluoroethylene is used as stationary phase and 5.5 M nitric acid is used as movie phase. The influence of matrix-component elements was studies. The development procedure was applied to real samples, being the results compared with those obtained by other well established analytical methods like gamma-spectrometry, laser fluorimetric, spectrophotometry previous uranium separation by liquid liquid extraction and anion exchange. The reproducibility is evaluated and the detection limited has been established for each studied matrix. A procedure for correcting the thorium interference has been developed for samples with a Th/ 3U8O higher than 0.2

  15. Spectrophotometric Determination of Zinc Using 7-(4-Nitrophenylazo-8-Hydroxyquinoline-5-Sulfonic Acid

    Korn Maria das Graças Andrade

    1999-01-01

    Full Text Available A sensitive and selective spectrophotometric method is proposed for the rapid determination of zinc(II using an 8-hydroxyquinoline derivative, 7-(4-nitrophenylazo-8-hydroxyquinoline-5-sulfonic acid (p-NIAZOXS, as a new spectrophotometric reagent. The reaction between the p-NIAZOXS and zinc(II is instantaneous at pH 9.2 (borax buffer and the absorbance remains stable for over 24 h. The method allows the determination of zinc over the range of 0.05-1.0 mug mL-1 with a molar absorptivity of 3.75x10(4 L mol-1 cm-1 and features a detection limit of 15 ng mL-1. The proposed method has been successfully applied to the determination of zinc in several pharmaceutical preparations and copper alloys. The precision (R.S.D. < 2% and the accuracy obtained were satisfactory.

  16. Spectrophotometric determination of metals in Pakistani and foreign brand cigarette tobacco

    Ikram, M.; Rauf, M.A.; Ali, S.; Iqbal, M.

    2001-01-01

    Tobacco smoking and related uses are major cause of various diseases in human beings. In the present study forty one various brands of cigarettes from Pakistan, United States, United Kingdom and Japan have been selected for determination of iron, nickel and copper spectrophotometrically. The concentration of Fe, Ni and Cu in tobacco of each forty-one brands of national and foreign brands cigarette is given in this article. The spectrophotometric determination of Fe, Ni and Cu in forty one brands of national and foreign cigarettes reveals that the concentrations of these metals depends on different conditions, such as soil condition, fertilizer and sprays during the tobacco growth. However, Cigarette manufacturing companies could have a significant role in their concentration levels. The results obtained by this technique are in good agreement with the reported literature values. (A.B.)

  17. Spectrophotometric method of the determination of gold (III) by using imipramine hydrochloride and promethazine hydrochloride

    Dembinski, B.; Kurzawa, M.; Szydlowska-Czerniak, A.

    2003-01-01

    Imipramine hydrochloride (IPM.HCl) and promethazine hydrochloride (PMT-HCl) were used for the spectrophotometric determination of gold (III) in the aqueous solution. The halides complexes of gold (III) created a coloured coupling with the studied drugs which were extractable in chloroform. These new compounds were characterized by IR,UV-VIS spectra and thermal and elemental analysis. Rapid and sensitive spectrophotometric method for the determination of gold (III) in the aqueous solution is described. The absorbance was found to be linear function of the gold (III) concentration in the range from 0.2 to 20 x10/sup -1/ mg. The ratio of complex (AuX/sub 4/) to the organic cation from drug in the obtained compounds was determined as 1:1. The method was satisfactorily applied to the analysis of gold (III). A great advantage of the proposed method is that the trace amounts of gold (III) can also be examined. (author)

  18. The analysis of impurities in the diuranate-determination of phosphate by phosphomolybdate blue spectrophotometric method

    Sun Haobo

    2014-01-01

    Phosphomolybdenum blue spectrophotometric method was used for determination of phosphate in the diuranate. Diuranate was dissolved in nitric acid solution, in which formed a soluble heteropolyacid complex (namely phosphomolybdenum yellow) due to interaction of phosphate and ammonium molybdate. Then phosphomolybdenum yellow was reduced to phosphomolybdenum blue with Bismuth nitrate as catalyst. Colour intensity at 700 nm is in proportion to the content of phosphate determined by spectrophotometric method. This experiment presents good linearity at the range of 30 μg to 245 μg phosphate, and the relative standard deviation of the experimental result is 2.4%, and the recovery rate is from 95% to 105%. The determination result of phosphate content will not be effected under conditions of 4 mg of SiO 2 , 6 mg of Fe, 400 mg of Cl - and 4.5 mg of Ge in the solution. (author)

  19. Evaluation of the Esthetic Properties of Developmental Defects of Enamel: A Spectrophotometric Clinical Study

    Fabrizio Guerra

    2015-01-01

    Full Text Available Objectives. Detailed clinical quantification of optical properties of developmental defect of enamel is possible with spectrophotometric evaluation. Developmental defects of enamel (DDE are daily encountered in clinical practice. DDE are an alteration in quality and quantity of the enamel, caused by disruption and/or damage to the enamel organ during amelogenesis. Methods. Several clinical indices have been developed to categorize enamel defects based on their nature, appearance, microscopic features, or cause. A sample of 39 permanent teeth presenting DDE on labial surface was examined using the DDE Modified Index and SpectroShade evaluation. The spectrophotometric approach quantifies L* (luminosity, a* (quantity of green-red, and b* (quantity of blue-yellow of different DDE. Conclusions. SpectroShade evaluation of the optical properties of the enamel defect enhances clinical understanding of severity and extent of the defect and characterizes the enamel alteration in terms of color discrepancy and surface characterization.

  20. Estimation of very low concentrations of Ruthenium by spectrophotometric method using barbituric acid as complexing agent

    Ramakrishna Reddy, S.; Srinivasan, R.; Mallika, C.; Kamachi Mudali, U.; Natarajan, R.

    2012-01-01

    Spectrophotometric method employing numerous chromogenic reagents like thiourea, 1,10-phenanthroline, thiocyanate and tropolone is reported in the literature for the estimation of very low concentrations of Ru. A sensitive spectrophotometric method has been developed for the determination of ruthenium in the concentration range 1.5 to 6.5 ppm in the present work. This method is based on the reaction of ruthenium with barbituric acid to produce ruthenium(ll)tris-violurate, (Ru(H 2 Va) 3 ) -1 complex which gives a stable deep-red coloured solution. The maximum absorption of the complex is at 491 nm due to the inverted t 2g → Π(L-L ligand) electron - transfer transition. The molar absorptivity of the coloured species is 9,851 dm 3 mol -1 cm -1

  1. Making limb and nadir measurements comparable: A common volume study of PMC brightness observed by Odin OSIRIS and AIM CIPS

    Benze, Susanne; Gumbel, Jörg; Randall, Cora E.; Karlsson, Bodil; Hultgren, Kristoffer; Lumpe, Jerry D.; Baumgarten, Gerd

    2018-01-01

    Combining limb and nadir satellite observations of Polar Mesospheric Clouds (PMCs) has long been recognized as problematic due to differences in observation geometry, scattering conditions, and retrieval approaches. This study offers a method of comparing PMC brightness observations from the nadir-viewing Aeronomy of Ice in the Mesosphere (AIM) Cloud Imaging and Particle Size (CIPS) instrument and the limb-viewing Odin Optical Spectrograph and InfraRed Imaging System (OSIRIS). OSIRIS and CIPS measurements are made comparable by defining a common volume for overlapping OSIRIS and CIPS observations for two northern hemisphere (NH) PMC seasons: NH08 and NH09. We define a scattering intensity quantity that is suitable for either nadir or limb observations and for different scattering conditions. A known CIPS bias is applied, differences in instrument sensitivity are analyzed and taken into account, and effects of cloud inhomogeneity and common volume definition on the comparison are discussed. Not accounting for instrument sensitivity differences or inhomogeneities in the PMC field, the mean relative difference in cloud brightness (CIPS - OSIRIS) is -102 ± 55%. The differences are largest for coincidences with very inhomogeneous clouds that are dominated by pixels that CIPS reports as non-cloud points. Removing these coincidences, the mean relative difference in cloud brightness reduces to -6 ± 14%. The correlation coefficient between the CIPS and OSIRIS measurements of PMC brightness variations in space and time is remarkably high, at 0.94. Overall, the comparison shows excellent agreement despite different retrieval approaches and observation geometries.

  2. Spectrophotometric determination of Fe(II) in Geological Materials by Using Ferrozine as Cromogenic Reagent

    Sanchez, D. M.; Martin, R.; Marin, J.; Morante, R.; Gutierrez, L.; Bayon, A.

    1999-12-01

    A rapid and sensitive spectrophotometric method for the determination of labile ferrous iron in geological materials is described. Samples are treated by boiling with hydrochloric acid for 60 min. in an atmosphere of carbon dioxide. Systematic erroneous results due to high concentrations of ferric iron are resolved. The limit of detection for the method was 0.02% of FeO. International standard granites analysed by the proposed method showed recoveries ranged from 81-102%. (Author) 9 refs

  3. Spectrophotometric-isotope dilution determination of arsenic in soils and rock

    Brown, F.W.; Simon, F.O.; Greenland, L.P.

    1975-01-01

    Arsenic in soil and rock samples may be determined in part-per-million concentrations using a radiochemical-isotope dilution method. Arsenic in the sample plus added As76 tracer is separated as arsine and determined spectrophotometrically as a molybdenum blue complex. The As76 activity in the absorbing solution allows corrections for chemical losses. A lower limit of 1 ppm is determinate in a 0.5-g sample.

  4. Stopped-flow injection spectrophotometric method for determination of chlorate in soil

    Jaroon Jakmunee

    2008-01-01

    A stopped-flow injection (FI) spectrophotometric procedure based on iodometric reaction for the determination of chlorate has been developed. Standard/sample was injected into a stream of potassium iodide solution and then merged with a stream of hydrochloric acid solution to produce triiodide. By stopping the flow while the sample zone is being in a mixing coil, a slow reaction of chlorate with iodide in acidic medium was promoted to proceed with minimal dispersion of the triiodide product z...

  5. Microchemical analysis of materials based on Y-Ba-Cu by spectrophotometric titration

    Kuznetsov, V.V.; Samorukova, O.L.; Zakharov, Eh.K.

    1990-01-01

    A complex method for analysis of superconductor and similar materials on Y-Ba-Cu basis has been developed, which comprises yttrium and copper determination by their indicator spectrophotometric titration by EDTA and/or complexone 4 in the presence of arsenazo 3. The use of complexone 4 is more favourable. Titration is carried out at λ=650 nm. The method has a sufficient accuracy, provides for rapid determination and does not reguire preliminary separation of components

  6. DETERMINATION OF PROTOPINE IN FUMARIA DENSIFLORA DC. BY TLC- DENSITOMETRIC AND SPECTROPHOTOMETRIC METHOD

    FAFAL, Tuğçe; ÖNÜR, Mustafa Ali

    2007-01-01

    The isoquinoline alkaloid protopine in Fumaria densiflora DC. (Fumariaceae) was quantitatively determined by TLC-densitometry and spectrophotometry. In TLC-densitometry two different solvent systems as toluene : chloroform : methanol : % 25 ammonium hydroxide (5:3:1:1) and cyclohexane : diethylamine (9:1) were used and protopine was detected as 0.351 and 0.352 % respectively. The content of protopine in Fumaria densiflora DC. was estimated as 0.366 % in spectrophotometric method. The quantita...

  7. SPECTROPHOTOMETRIC METHOD FOR SIMULTANEOUS ESTIMATION OF TOLPERISONE HYDROCHLORIDE AND DICLOFENAC SODIUM IN SYNTHETIC MIXTURE

    Patel Satish A; Hariyani Kaushik P

    2012-01-01

    The present manuscript describes simple, sensitive, rapid, accurate, precise and economical spectrophotometric method for the simultaneous determination of Diclofenac sodium and Tolperisone hydrochloride in bulk and synthetic mixture. The method is based on the simultaneous equations for analysis of both the drugs using methanol as solvent. Diclofenac sodium has absorbance maxima at 281 nm and Tolperisone hydrochloride has absorbance maxima at 255 nm in methanol. The linearity was obtained in...

  8. SPECTROPHOTOMETRIC METHOD FOR SIMULTANEOUS ESTIMATION OF EPERISONE HYDROCHLORIDE AND DICLOFENAC SODIUM IN SYNTHETIC MIXTURE

    Patel Paresh U; Patel Sejal K; Patel Umang J

    2012-01-01

    The present manuscript describes simple, sensitive, rapid, accurate, precise and economical spectrophotometric method for the simultaneous determination of diclofenac sodium and Eperisone hydrochloride in bulk and synthetic mixture. The method is based on the simultaneous equations for analysis of both the drugs using methanol as solvent. Diclofenac sodium has absorbance maxima at 281 nm and Eperisone hydrochloride has absorbance maxima at 255 nm in methanol. The linearity was obtained in the...

  9. Spectrophotometric determination of silica in water. Low range; Determinacion espectrofotometrica de silicio en aguas. Rango bajo

    Acosta L, E. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: eal@nuclear.inin.mx

    1992-07-15

    The spectrophotometric method for the determination of the silica element in water, demineralized water, raw waters, laundry waters, waters treated with ion exchange resins and sea waters is described. This method covers the determination of the silica element in the interval from 20 to 1000 {mu}g/l on 50 ml. of base sample. These limits its can be variable if the size of the used aliquot one is changed for the final determination of the silica element. (Author)

  10. Spectrophotometric and spectrofluorometric determination of uranium using a flotation process with benzoate and rivanol

    Lopez Herroz, C.; Hernandez, M.; Sanchez-Pedreno, C.

    1988-01-01

    Tribenzouranyl anion forms with rivnol an ion-association compound which is floated with isopropyl ether and dissolved in ethanol. As a consequence, new spectrophotometric and spectrofluorimetric methods for the determination of trace amounts of uranium are developed. At 373 nm Beer's law is obeyed over the range 10-150 /mu/g of uranium. When the spectrofluorimetric technique is used, calibration graph is linear in the 2-25 /mu/g range.

  11. Spectrophotometric determination of low levels arsenic species in beverages after ion-pairing vortex-assisted cloud-point extraction with acridine red.

    Altunay, Nail; Gürkan, Ramazan; Kır, Ufuk

    2016-01-01

    A new, low-cost, micellar-sensitive and selective spectrophotometric method was developed for the determination of inorganic arsenic (As) species in beverage samples. Vortex-assisted cloud-point extraction (VA-CPE) was used for the efficient pre-concentration of As(V) in the selected samples. The method is based on selective and sensitive ion-pairing of As(V) with acridine red (ARH(+)) in the presence of pyrogallol and sequential extraction into the micellar phase of Triton X-45 at pH 6.0. Under the optimised conditions, the calibration curve was highly linear in the range of 0.8-280 µg l(-1) for As(V). The limits of detection and quantification of the method were 0.25 and 0.83 µg l(-1), respectively. The method was successfully applied to the determination of trace As in the pre-treated and digested samples under microwave and ultrasonic power. As(V) and total As levels in the samples were spectrophotometrically determined after pre-concentration with VA-CPE at 494 nm before and after oxidation with acidic KMnO4. The As(III) levels were calculated from the difference between As(V) and total As levels. The accuracy of the method was demonstrated by analysis of two certified reference materials (CRMs) where the measured values for As were statistically within the 95% confidence limit for the certified values.

  12. Semi-empirical spectrophotometric (SESp) method for the indirect determination of the ratio of cationic micellar binding constants of counterions X⁻ and Br⁻(K(X)/K(Br)).

    Khan, Mohammad Niyaz; Yusof, Nor Saadah Mohd; Razak, Norazizah Abdul

    2013-01-01

    The semi-empirical spectrophotometric (SESp) method, for the indirect determination of ion exchange constants (K(X)(Br)) of ion exchange processes occurring between counterions (X⁻ and Br⁻) at the cationic micellar surface, is described in this article. The method uses an anionic spectrophotometric probe molecule, N-(2-methoxyphenyl)phthalamate ion (1⁻), which measures the effects of varying concentrations of inert inorganic or organic salt (Na(v)X, v = 1, 2) on absorbance, (A(ob)) at 310 nm, of samples containing constant concentrations of 1⁻, NaOH and cationic micelles. The observed data fit satisfactorily to an empirical equation which gives the values of two empirical constants. These empirical constants lead to the determination of K(X)(Br) (= K(X)/K(Br) with K(X) and K(Br) representing cationic micellar binding constants of counterions X and Br⁻). This method gives values of K(X)(Br) for both moderately hydrophobic and hydrophilic X⁻. The values of K(X)(Br), obtained by using this method, are comparable with the corresponding values of K(X)(Br), obtained by the use of semi-empirical kinetic (SEK) method, for different moderately hydrophobic X. The values of K(X)(Br) for X = Cl⁻ and 2,6-Cl₂C6H₃CO₂⁻, obtained by the use of SESp and SEK methods, are similar to those obtained by the use of other different conventional methods.

  13. EVALUATING THE ACCUMULATION TREND OF L-DOPA IN DARK-GERMINATED SEEDS AND SUSPENSION CULTURES OF Phaseolus vulgaris L. BY AN EFFICIENT UV-SPECTROPHOTOMETRIC METHOD

    Samira Rahmani-Nezhad

    Full Text Available Seed germination and plant cell cultures provide an alternative mean for producing secondary metabolites. The present study is an attempt to evaluate the effect of seed dark germination and some elicitors and precursors on the production of L-DOPA in Phaseolus vulgaris L. Callus cultured on Murashige and Skoog medium supplemented with various concentrations of different plant growth regulators. L-DOPA produced was quantified by UV-spectrophotometric method. In this study, a user-friendly, quick, and economical UV-spectrophotometric method was described to determine L-DOPA content in extracts from 33 biotypes of Phaseolus vulgaris L. The method is based on the nitrosation of L-DOPA to form a yellow solution and then formation of a red solution by adding base which is measurable at 470 nm. According to our statistical studies, this method showed high efficiency and selectivity for quantitative determination of L-DOPA in herbal extracts from dried plant seeds, dark-germinated seeds and callus cultures. L-DOPA content in dark-germinated seeds and suspension cultures increased significantly to approximately several-fold compared to the control. The implication from this study is that elicitor treatment and precursor feeding of Phaseolus vulgaris L. can significantly improve the parkinson’s relevant L-DOPA content.

  14. Spectrophotometric titrations: Application to the determination of some elements in uranium solutions

    L'Her, M.

    1967-01-01

    The aim of this work is the application of spectrophotometric titrations to the analysis of uranium-containing solutions. We have been led to examine the general principles involved in these titrations, and we give a brief outline of these principles. In the first part we deal therefore with spectrophotometric titrations from a general point of view, examining their fundamental principle, their practical execution as well as the various possibilities of the method. The advantage of the titration are examined, in particular that of lending itself simultaneous determination of two species. The possibility of applying these spectrophotometric titrations to the analysis of uranium-containing solutions is the subject of the second part of this report: the dosage of a few species in uranium (VI) solutions is described. To this second part is added an experimental appendix consisting of a description of the apparatus, as well as of the operational techniques used for certain titrations, in particular those involving solutions containing uranium. (author) [fr

  15. OPTIMIZING CONDITIONS FOR SPECTROPHOTOMETRIC DETERMINATION OF TOTAL POLYPHENOLS IN WINES USING FOLIN-CIOCALTEU REAGENT

    Daniel Bajčan

    2013-02-01

    Full Text Available Wine is a complex beverage that obtains its properties mainly due to synergistic effect of alcohol, organic acids, arbohydrates, as well as the phenolic and aromatic substances. At present days, we can observe an increased interest in the study of polyphenols in wines that have antioxidant, antimicrobial, anti-inflammatory, anti-cancer and many other beneficial effects. Moderate and regular consumption of the red wine especially, with a high content of phenolic compounds, has a beneficial effect on human health. The aim of this work was to optimize conditions for spectrophotometric determination of total polyphenols in winwas to optimize conditions for spectrophotometric determination of total polyphenols in winwas to optimize conditions for spectrophotometric determination of total polyphenols in winwas to optimize conditions for pectrophotometric determination of total polyphenols in wine using Folin-Ciocaulteu reagent. Based on several studies, in order to minimize chemical use and optimize analysis time, we have proposed a method for the determination of total polyphenols using 0.25 ml Folin-Ciocaulteu reagent, 3 ml of 20% Na2CO3 solution and time of coloring complex 1.5 hour. We f

  16. Spectrophotometric determination of Sn+2 in lyophilized kit for labeling with 99mTc

    Araujo, Elaine Bortoleti; Sampel, Carolina Judith; Melo, Ivani Bortoleti; Okamoto, Miriam R.Y; Silva, Constancia P.G

    2004-01-01

    The preparation of 99 mTc labeled radiopharmaceuticals depends on the reduction of the technetium pertechnetate, commonly by stannous chloride (SnCl 2 ). The determination of the Sn +2 contents in the lyophilized preparations represents an important quality control procedure that may be applied to the process and to the final product. The objective os this work is the optimization of an spectrophotometric assay to the determination os Sn +2 contents in a citrate-stannous lyophilized kit for 99 mTc labeling. The spectrophotometric methodology employed is based in the colour development when Sn +2 reacts with sodium molybdate in the presence of potasium thiocyanate in chloridric medium. The colourfull reaction studied showed high stability after 60 minutes of the mixtures preparation. The sequence of reagents introduction in the reaction mixture was determinant to the assay. The molibdenium-stannous-tiocianate sequence produces calibration curves with good correlations (R2 ≥ 0.99). The concentrations of the molibdenium solution was also studied, in order to determine a ideal concentration for the Sn +2 range. The spectrophotometric method studied was usefull to the determination of Sn +2 content in different batches of citrate-stannous preparations. The method was fast and easy and can be applied to different stages of the production process, in order to guarantee the content of Sn +2 in the preparations (Au)

  17. INTER-RATER RELIABILITY FOR MOVEMENT PATTERN ANALYSIS (MPA: MEASURING PATTERNING OF BEHAVIORS VERSUS DISCRETE BEHAVIOR COUNTS AS INDICATORS OF DECISION-MAKING STYLE

    Brenda L Connors

    2014-06-01

    Full Text Available The unique yield of collecting observational data on human movement has received increasing attention in a number of domains, including the study of decision-making style. As such, interest has grown in the nuances of core methodological issues, including the best ways of assessing inter-rater reliability. In this paper we focus on one key topic – the distinction between establishing reliability for the patterning of behaviors as opposed to the computation of raw counts – and suggest that reliability for each be compared empirically rather than determined a priori. We illustrate by assessing inter-rater reliability for key outcome measures derived from Movement Pattern Analysis (MPA, an observational methodology that records body movements as indicators of decision-making style with demonstrated predictive validity. While reliability ranged from moderate to good for raw counts of behaviors reflecting each of two Overall Factors generated within MPA (Assertion and Perspective, inter-rater reliability for patterning (proportional indicators of each factor was significantly higher and excellent (ICC = .89. Furthermore, patterning, as compared to raw counts, provided better prediction of observable decision-making process assessed in the laboratory. These analyses support the utility of using an empirical approach to inform the consideration of measuring discrete behavioral counts versus patterning of behaviors when determining inter-rater reliability of observable behavior. They also speak to the substantial reliability that may be achieved via application of theoretically grounded observational systems such as MPA that reveal thinking and action motivations via visible movement patterns.

  18. Convective Leakage Makes Heparin Locking of Central Venous Catheters Ineffective Within Seconds: Experimental Measurements in a Model Superior Vena Cava.

    Barbour, Michael C; McGah, Patrick M; Ng, Chin H; Clark, Alicia M; Gow, Kenneth W; Aliseda, Alberto

    2015-01-01

    Central venous catheters (CVCs), placed in the superior vena cava (SVC) for hemodialysis or chemotherapy, are routinely filled while not in use with heparin, an anticoagulant, to maintain patency and prevent thrombus formation at the catheter tip. The heparin-locking procedure, however, places the patient at risk for systemic bleeding, as heparin is known to leak from the catheter into the blood stream. We provide evidence from detailed in vitro experiments that shows the driving mechanism behind heparin leakage to be convective-diffusive transport due to the pulsatile flow surrounding the catheter. This novel mechanism is supported by experimental planar laser-induced fluorescence (PLIF) and particle image velocimetry (PIV) measurements of flow velocity and heparin transport from a CVC placed inside a model SVC inside a pulsatile flow loop. The results predict an initial, fast (<10 s), convection-dominated phase that rapidly depletes the concentration of heparin in the near-tip region, the region of the catheter with side holes. This is followed by a slow, diffusion-limited phase inside the catheter lumen, where the concentration is still high, that is insufficient at replenishing the lost heparin concentration in the near-tip region. The results presented here, which are consistent with previous in vivo estimates of 24 hour leakage rates, predict that the concentration of heparin in the near-tip region is essentially zero for the majority of the interdialytic phase, rendering the heparin locking procedure ineffective.

  19. Undertaking high impact strategies: The role of national efficiency measures in long-term energy and emission reduction in steel making

    Xu, Tengfang; Karali, Nihan; Sathaye, Jayant

    2014-01-01

    Highlights: • Evaluate long-term effects of national energy efficiency in steel making. • Use bottom-up optimization for projection in China, India and the U.S. • The effects include changes in steel production, energy use, emissions, and costs. • Three emission targets induce different structural changes and investments. • Projected energy and CO 2 intensity declines in each country from 2010 to 2050. - Abstract: In this paper, we applied bottom-up linear optimization modeling to analyze long-term national impacts of implementing energy efficiency measures on energy savings, CO 2 -emission reduction, production, and costs of steel making in China, India, and the U.S. We first established two base scenarios representing business-as-usual steel production for each country from 2010 to 2050; Base scenario (in which no efficiency measure is available) and Base-E scenario (in which efficiency measures are available), and model scenarios representing various emission-reduction targets that affects production, annual energy use and costs with the goal of cost minimization. A higher emission-reduction target generally induces larger structural changes and increased investments in nation-wide efficiency measures, in addition to autonomous improvement expected in the Base scenario. Given the same emission-reduction target compared to the base scenario, intensity of annual energy use and emissions exhibits declining trends in each country from year 2010 to 2050. While a higher emission-reduction target result in more energy reduction from the base scenario, such reduction can become more expensive to achieve. The results advance our understanding of long-term effects of national energy efficiency applications under different sets of emission-reduction targets for steel sectors in the three major economies, and provide useful implications for high impact strategies to manage production structures, production costs, energy use, and emission reduction in steel making

  20. Novel microwell-based spectrophotometric assay for determination of atorvastatin calcium in its pharmaceutical formulations

    Abdel-Rahman Hamdy M

    2011-10-01

    Full Text Available Abstract The formation of a colored charge-transfer (CT complex between atorvastatin calcium (ATR-Ca as a n-electron donor and 2, 3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ as a π-electron acceptor was investigated, for the first time. The spectral characteristics of the CT complex have been described, and the reaction mechanism has been proved by computational molecular modeling. The reaction was employed in the development of a novel microwell-based spectrophotometric assay for determination of ATR-Ca in its pharmaceutical formulations. The proposed assay was carried out in 96-microwell plates. The absorbance of the colored-CT complex was measured at 460 nm by microwell-plate absorbance reader. The optimum conditions of the reaction and the analytical procedures of the assay were established. Under the optimum conditions, linear relationship with good correlation coefficient (0.9995 was found between the absorbance and the concentration of ATR-Ca in the range of 10-150 μg/well. The limits of detection and quantitation were 5.3 and 15.8 μg/well, respectively. No interference was observed from the additives that are present in the pharmaceutical formulation or from the drugs that are co-formulated with ATR-Ca in its combined formulations. The assay was successfully applied to the analysis of ATR-Ca in its pharmaceutical dosage forms with good accuracy and precision. The assay described herein has great practical value in the routine analysis of ATR-Ca in quality control laboratories, as it has high throughput property, consumes minimum volume of organic solvent thus it offers the reduction in the exposures of the analysts to the toxic effects of organic solvents, and reduction in the analysis cost by 50-fold. Although the proposed assay was validated for ATR-Ca, however, the same methodology could be used for any electron-donating analyte for which a CT reaction can be performed.

  1. Spectrophotometric methods for the determination of ampicillin by potassium permanganate and 1-chloro-2,4-dinitrobenzene in pharmaceutical preparations

    Aftab Aslam Parwaz Khan

    2015-03-01

    Full Text Available Two simple and sensitive kinetic methods for the determination of ampicillin (AMP are described. The first method is based on kinetic investigation of the oxidation reaction of the drug with alkaline potassium permanganate at room temperature for a fixed time of 25 min. The absorbance of the colored manganate ions is measured at 610 nm. The second method is based on the reaction of AMP with 1-chloro-2,4-dinitrobenzene (CDNB in the presence of 0.1 mol L−1 sodium bicarbonate. Spectrophotometric measurement was achieved by recording the absorbance at 490 nm for a fixed time of 60 min. All variables affecting the development of the color were investigated and the conditions were optimized. Plots of absorbance against concentration in both procedures were rectilinear over the ranges 5–30 and 50–260 μg mL−1, with mean recoveries 99.80 and 99.91, respectively. The proposed methods were successfully applied for the determination of AMP in bulk powder and in capsule dosage form. The determination of AMP by the fixed concentration method is feasible with the calibration equations obtained, but the fixed time method proves to be more applicable.

  2. A simple and selective spectrophotometric flow injection determination of trace amounts of ruthenium by catalytic oxidation of safranin-O

    Rezaei, Behzad [Department of Chemistry, Isfahan University of Technology, Isfahan 84156-84111 (Iran, Islamic Republic of)], E-mail: rezaei@cc.iut.ac.ir; Keyvanfard, Mohsen [Faculty of Science, Majlesi Campus, Islamic Azad University, Isfahan (Iran, Islamic Republic of)

    2008-03-01

    In this work, a simple, selective and rapid flow injection method has been developed for determination of ruthenium. The method is based on its catalytic effect on the oxidation of safranin-O by metaperiodate. The reaction was monitored spectrophotometrically by measuring safranin-O absorbance at {lambda}{sub max} = 521. The reagents and manifold variables, which have influences on the sensitivity, were investigated and the optimum conditions were established. The optimized conditions made it possible to determine ruthenium in the ranges of 0.4-20.0 ng/mL ({delta}A = 0.2819C{sub Ru} + 1.1840) and 20.0-100.0 ng/mL ({delta}A = 0.0984C{sub Ru} + 7.9391) with a detection limit of 0.095 ng/mL and a sample rate of 30 {+-} 5 samples/h. Relative standard deviation for the five replicate measurements was less than 1.84%. The proposed method has been successfully applied for analysis of ultra trace amounts of ruthenium in real samples.

  3. A simple and selective spectrophotometric flow injection determination of trace amounts of ruthenium by catalytic oxidation of safranin-O

    Rezaei, Behzad; Keyvanfard, Mohsen

    2008-01-01

    In this work, a simple, selective and rapid flow injection method has been developed for determination of ruthenium. The method is based on its catalytic effect on the oxidation of safranin-O by metaperiodate. The reaction was monitored spectrophotometrically by measuring safranin-O absorbance at λ max = 521. The reagents and manifold variables, which have influences on the sensitivity, were investigated and the optimum conditions were established. The optimized conditions made it possible to determine ruthenium in the ranges of 0.4-20.0 ng/mL (ΔA = 0.2819C Ru + 1.1840) and 20.0-100.0 ng/mL (ΔA = 0.0984C Ru + 7.9391) with a detection limit of 0.095 ng/mL and a sample rate of 30 ± 5 samples/h. Relative standard deviation for the five replicate measurements was less than 1.84%. The proposed method has been successfully applied for analysis of ultra trace amounts of ruthenium in real samples

  4. A structured review of spinal stiffness as a kinesiological outcome of manipulation: its measurement and utility in diagnosis, prognosis and treatment decision-making.

    Snodgrass, Suzanne J; Haskins, Robin; Rivett, Darren A

    2012-10-01

    To review and discuss the methods used for measuring spinal stiffness and factors associated with stiffness, how stiffness is used in diagnosis, prognosis, and treatment decision-making and the effects of manipulative techniques on stiffness. A systematic search of MEDLINE, EMBASE, CINAHL, AMED and ICL databases was conducted. Included studies addressed one of four constructs related to stiffness: measurement, diagnosis, prognosis and/or treatment decision-making, and the effects of manipulation on stiffness. Spinal stiffness was defined as the relationship between force and displacement. One hundred and four studies are discussed in this review, with the majority of studies focused on the measurement of stiffness, most often in asymptomatic persons. Eight studies investigated spinal stiffness in diagnosis, providing limited evidence that practitioner-judged stiffness is associated with radiographic findings of sagittal rotational mobility. Fifteen studies investigated spinal stiffness in prognosis or treatment decision-making, providing limited evidence that spinal stiffness is unlikely to independently predict patient outcomes, though stiffness may influence a practitioner's application of non-thrust manipulative techniques. Nine studies investigating the effects of manipulative techniques on spinal stiffness provide very limited evidence that there is no change in spinal stiffness following thrust or non-thrust manipulation in asymptomatic individuals and non-thrust techniques in symptomatic persons, with only one study supporting an immediate, but not sustained, stiffness decrease following thrust manipulation in symptomatic individuals. The existing limited evidence does not support an association between spinal stiffness and manipulative treatment outcomes. There is a need for additional research investigating the effects of manipulation on spinal stiffness in persons with spinal pain. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Tacit and encoded knowledge in the use of standardised outcome measures in multidisciplinary team decision making: a case study of in-patient neurorehabilitation.

    Greenhalgh, Joanne; Flynn, Rob; Long, Andrew F; Tyson, Sarah

    2008-07-01

    This paper explores how multidisciplinary teams (MDTs) balance encoded knowledge, in the form of standardised outcome measurement, with tacit knowledge, in the form of intuitive judgement, clinical experience and expertise, in the process of clinical decision making. The paper is based on findings from a qualitative case study of a multidisciplinary in-patient neurorehabilitation team in one UK NHS trust who routinely collected standardised outcome measures. Data were collected using non-participant observation of 16 MDT meetings and semi-structured interviews with 11 practitioners representing different professional groups. Our analysis suggests that clinicians drew on tacit knowledge to supplement, adjust or dismiss 'the scores' in making judgements about a patients' likely progress in rehabilitation, their change (or lack of) during therapy and their need for support on discharge. In many cases, the scores accorded with clinicians' tacit knowledge of the patient, and were used to reinforce this opinion, rather than determine it. In other cases, the scores, in particular the Barthel Index, provided a partial picture of the patient and in these circumstances, clinicians employed tacit knowledge to fill in the gaps. In some cases, the scores and tacit knowledge diverged and clinicians preferred to rely on their clinical experience and intuition and adjusted or downplayed the accuracy of the scores. We conclude that there are limits to the advantages of quantifying and standardising assessments of health within routine clinical practice and that standardised outcome measures can support, rather than determine clinical judgement. Tacit knowledge is essential to produce and interpret this form of encoded knowledge and to balance its significance against other information about the patient in making decisions about patient care.

  6. Comparison of two models for the X-ray dispersion produced in a Novillo Tokamak with measurements make with thermoluminescent dosemeters

    Flores O, A.; Castillo, A.; Barocio, S.R.; Melendez L, L.; Chavez A, E.; Cruz C, G.J.; Lopez, R.; Olayo, M.G.; Gonzalez M, P.; Azorin N, J.

    1999-01-01

    It was presented the results to study about the X-ray dispersion produced in the Novillo Tokamak using thermoluminescent dosemeters (DTL). The measurements were make in the equatorial plane of Tokamak, along twelve radial directions. The dispersion is observed due to the radiation interaction with walls surrounding the machine. It was proposed two types of heuristic mathematical methods for describing the X-ray dispersion, comparing them with the experimental data obtained with Dtl. The predictions of both models are adjusted well to the experimental data. (Author)

  7. Outlier detection in UV/Vis spectrophotometric data

    Lepot, M.J.; Aubin, Jean Baptiste; Clemens, F.H.L.R.; Mašić, Alma

    2017-01-01

    UV/Vis spectrophotometers have been used to monitor water quality since the early 2000s. Calibration of these devices requires sampling campaigns to elaborate relations between recorded spectra and measured concentrations. In order to build robust calibration data sets, several spectra must be

  8. Spectrophotometric flow-injection analysis assay of tetracycline antibiotics using a dual light-emitting diode based detector

    Prinya Masawat

    2008-02-01

    Full Text Available In this paper, a small dual light-emitting diode (LED-based detector for FIA process analyser has been designed. The detector’s optical parts comprise a flow-through cell, a dual-blue LED and a photodiode. Neither mirrors nor lenses are used. The optical path for the first LED detects the blank, while the other LED detects the sample. The detector’s electronic components including a signal amplifier and an A/D converter are integrated on one small board connected to a PC for measuring the results. The designed spectrophotometric detector was used for the determination of tetracycline antibiotics. Uranyl acetate was used as a reagent forming orange-red complexes with the drugs in N,N– dimethylformamide. The complexes show absorption maxima at 410, 416 and 408 nm for tetracycline hydrochloride (TCH, chlortetracycline hydrochloride (CTCH, and doxycycline hydrochloride (DCH, respectively. The detection limit was found to be 0.38, 0.75, 1.44 µg mL-1 and the linear range was obtained at 1.0-3.0, 3.0-5.0, and 3.0-10.0 µg mL-1 for TCH, CTCH and DCH, respectively. The proposed method has been successfully applied to the determination of tetracycline antibiotic residues in milk samples. Moreover, this method is an environmentally friendly approach and suitable for routine analysis.

  9. Development of an indirect spectrophotometric method for determination of methamidophos insecticide in soil, water and vegetable samples

    J. Shah

    2015-07-01

    Full Text Available A simple and rapid indirect spectrophotometric method for determination of methamidophos in water, soil and vegetable samples has been described. Methamidophos reacts with acid produced from p-dimethylaminobenzaldehyde (p-DMAB as a result of Cannizaro’s reaction. The resultant adduct undergoes condensation reaction in acidic medium forming a yellow colored product. Absorbance of the colored product was measured at 405 nm and pH 3 against a reagent blank. The Beer’s law range is obeyed in the range 1-30 µg mL-1 with molar absorptivity of 2.8 ×103 L mol-1 cm-1. The limit of detection and quantification were found to be 0.20±0.03 and 0.60±0.04 µg mL-1 respectively. The proposed method was effectively applied for determination of methamidophos in various samples with percent recoveries in the range of 96±0.08 to 102±0.06 %.

  10. Development of indirect spectrophotometric method for quantification of cephalexin in pure form and commercial formulation using complexation reaction

    Khan, M.N.; Hussain, R.; Kalsoom, S.; Saadiq, M.

    2016-01-01

    A simple, accurate and indirect spectrophotometric method was developed for the quantification of cephalexin in pure form and pharmaceutical products using complexation reaction. The developed method is based on the oxidation of the cephalexin with Fe/sup 3+/ in acidic medium. Then 1, 10- phenanthroline reacts with Fe/sup 2+/ and a red colored complex was formed. The absorbance of the complex was measured at 510 nm by spectrophotometer. Different experimental parameters affecting the complexation reactions were studied and optimized. Beer law was obeyed in the concentration range 0.4 -10 micro gmL/sup -1/ with a good correlation of 0.992. The limit of detection and limit of quantification were found to be 0.065 micro gmL/sup -1/ and 0.218 micro gmL/sup -1/ , respectively. The method have good reproducibility with a relative standard deviation of 6.26 percent (n = 6). The method was successfully applied for the determination of cephalexin in bulk powder and commercial formulation. Percent recoveries were found to range from 95.47 to 103.87 percent for the pure form and 98.62 to 103.35 percent for commercial formulations. (author)

  11. Spectrophotometric determination of β-adrenergic antagonists drugs via ion-pair complex formation using MO and EBT

    El-Didamony, A. M.; Shehata, A. M.

    2014-09-01

    Two simple, rapid and sensitive spectrophotometric methods have been proposed for the assay of bisoprolol fumarate (BSF), propranolol hydrochloride (PRH), and timolol maleate (TIM) either in bulk or in pharmaceutical formulations. The methods are based on the reaction of the selected drugs with methyl orange (MO) and eriochrome black T in acidic buffers, after extracting in dichloromethane and measured quantitatively with maximum absorption at 428 and 518 nm for MO and EBT, respectively. The analytical parameters and their effects on the reported systems are investigated. The extracts are intensely colored and very stable at room temperature. The calibration graphs were linear over the concentration range of 0.8-6.4, 0.4-3.6, 0.8-5.6 μg/mL for BSF, PRH, and TIM, respectively, with MO and 0.8-6.4, 0.4-3.2, and 0.8-8.0 μg/mL for BSF, PRH, and TIM, respectively, with EBT. The stoichiometry of the complexes was found to be 1 : 1 in all cases. The proposed methods were successfully extended to pharmaceutical preparations. Excipients used as additive in commercial formulations did not interfere in the analysis. The proposed methods can be recommended for quality control and routine analysis where time, cost effectiveness and high specificity of analytical technique are of great importance.

  12. Utility of Charge Transfer and Ion-Pair Complexation for Spectrophotometric Determination of Eletriptan Hydrobromide in Pure and Dosage Forms

    Ayman A. Gouda

    2013-01-01

    Full Text Available Three simple, sensitive, and accurate spectrophotometric methods have been developed for the determination of eletriptan hydrobromide (ELT in pure and dosage forms. The first two methods are based on charge transfer complex formation between ELT and chromogenic reagents quinalizarin (Quinz and alizarin red S (ARS producing charge transfer complexes which showed an absorption maximum at 569 and 533 nm for Quinz and ARS, respectively. The third method is based on the formation of ion-pair complex between ELT with molybdenum(V-thiocyanate inorganic complex in hydrochloric acid medium followed by extraction of the colored ion-pair with dichloromethane and measured at 470 nm. Different variables affecting the reactions were studied and optimized. Beer's law is obeyed in the concentration ranges 2.0–18, 1.0–8.0, and 2.0–32 μg mL−1 for Quinz, ARS, and Mo(V-thiocyanate, respectively. The molar absorptivity, Sandell sensitivity, detection, and quantification limits are also calculated. The correlation coefficients were ≥0.9994 with a relative standard deviation (R.S.D%. of ≤0.925. The proposed methods were successfully applied for simultaneous determination of ELT in tablets with good accuracy and precision and without interferences from common additives, and the validity is assessed by applying the standard addition technique, which is compared with those obtained using the reported method.

  13. Development and Validation of Spectrophotometric Methods for Simultaneous Estimation of Valsartan and Hydrochlorothiazide in Tablet Dosage Form

    Monika L. Jadhav

    2014-01-01

    Full Text Available Two UV-spectrophotometric methods have been developed and validated for simultaneous estimation of valsartan and hydrochlorothiazide in a tablet dosage form. The first method employed solving of simultaneous equations based on the measurement of absorbance at two wavelengths, 249.4 nm and 272.6 nm, λmax for valsartan and hydrochlorothiazide, respectively. The second method was absorbance ratio method, which involves formation of Q-absorbance equation at 258.4 nm (isoabsorptive point and also at 272.6 nm (λmax of hydrochlorothiazide. The methods were found to be linear between the range of 5–30 µg/mL for valsartan and 4–24 μg/mL for hydrochlorothiazide using 0.1 N NaOH as solvent. The mean percentage recovery was found to be 100.20% and 100.19% for the simultaneous equation method and 98.56% and 97.96% for the absorbance ratio method, for valsartan and hydrochlorothiazide, respectively, at three different levels of standard additions. The precision (intraday, interday of methods was found within limits (RSD<2%. It could be concluded from the results obtained in the present investigation that the two methods for simultaneous estimation of valsartan and hydrochlorothiazide in tablet dosage form are simple, rapid, accurate, precise and economical and can be used, successfully, in the quality control of pharmaceutical formulations and other routine laboratory analysis.

  14. Indirect spectrophotometric determination of sulfadiazine based on localized surface plasmon resonance peak of silver nanoparticles after cloud point extraction.

    Kazemi, Elahe; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Fattahi, Mohammad Reza; Khodaveisi, Javad

    2017-12-05

    A novel, efficient, easy to use, environmentally friendly and cost-effective methodology is developed for the indirect spectrophotometric determination of sulfadiazine in different samples. The method is based on the micelle-mediated extraction of silver sulfadiazine and converting the silver content of the resultant surfactant-rich phase to the silver nanoparticles via generation of [Ag(NH 3 ) 2 ] + followed by its chemical reduction using ascorbic acid. The changes in the amplitude of localized surface plasmon resonance peak of silver nanoparticles as a function of sulfadiazine concentration in the sample solution was monitored using fiber optic linear array spectrophotometry at 457nm. The experimental conditions were thoroughly investigated and optimized. Under the optimized condition, the developed procedure showed dynamic linear calibration within the range of 10.0-800.0μgL -1 with a detection limit of 2.8μgL -1 for sulfadiazine. The relative standard deviation of the method for six replicate measurements at 150.0μgL -1 of sulfadiazine was 4.7%. The developed method was successfully applied to the determination of sulfadiazine in different samples including well water, human urine, milk and pharmaceutical formulation. Copyright © 2017. Published by Elsevier B.V.

  15. Indirect spectrophotometric determination of sulfadiazine based on localized surface plasmon resonance peak of silver nanoparticles after cloud point extraction

    Kazemi, Elahe; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Fattahi, Mohammad Reza; Khodaveisi, Javad

    2017-12-01

    A novel, efficient, easy to use, environmentally friendly and cost-effective methodology is developed for the indirect spectrophotometric determination of sulfadiazine in different samples. The method is based on the micelle-mediated extraction of silver sulfadiazine and converting the silver content of the resultant surfactant-rich phase to the silver nanoparticles via generation of [Ag(NH3)2]+ followed by its chemical reduction using ascorbic acid. The changes in the amplitude of localized surface plasmon resonance peak of silver nanoparticles as a function of sulfadiazine concentration in the sample solution was monitored using fiber optic linear array spectrophotometry at 457 nm. The experimental conditions were thoroughly investigated and optimized. Under the optimized condition, the developed procedure showed dynamic linear calibration within the range of 10.0-800.0 μg L- 1 with a detection limit of 2.8 μg L- 1 for sulfadiazine. The relative standard deviation of the method for six replicate measurements at 150.0 μg L- 1 of sulfadiazine was 4.7%. The developed method was successfully applied to the determination of sulfadiazine in different samples including well water, human urine, milk and pharmaceutical formulation.

  16. Spectrophotometric study of Saturn's main rings by means of Monte Carlo ray-tracing and Hapke's theory

    Ciarniello, Mauro; Filacchione, Gianrico; D'Aversa, Emiliano; Cuzzi, Jeffrey N.; Capaccioni, Fabrizio; Hedman, Matthew M.; Dalle Ore, Cristina M.; Nicholson, Philip D.; Clark, Roger Nelson; Brown, Robert H.; Cerroni, Priscilla; Spilker, Linda

    2017-10-01

    This work is devoted to the investigation of the spectrophotometric properties of Saturn's rings from Cassini-VIMS (Visible and Infrared Mapping Spectrometer) observations. The dataset used for this analysis is represented by ten radial spectrograms of the rings which have been derived in Filacchione et al. (2014) by radial mosaics produced by VIMS. Spectrograms report the measured radiance factor of the main Saturn's rings as a function of both radial distance (from 73.500 to 141.375 km) and wavelength (0.35-5.1 µm) for different observation geometries (phase angle ranging in the 1.9°-132.2° interval). We take advantage of a Monte Carlo ray-tracing routine to characterize the photometric behavior of the rings at each wavelength and derive the spectral Bond albedo of rings particles. This quantity is used to infer the composition of the regolith covering rings particles by applying Hapke's theory. Four different regions, characterized by different optical depths, and respectively located in the C ring, inner B ring, mid B ring and A ring, have been investigated. Results from spectral modeling indicate that rings spectrum can be described by water ice with minimal inclusion of organic materials (tholin, exogenous material, which is more effective in the less dense regions of the rings because of their lower content of pure water ice.

  17. First derivative spectrophotometric determination of granisetron hydrochloride in presence of its hydrolytic products and preservative and application to pharmaceutical preparations.

    Hewala, Ismail I; Bedair, Mona M; Shousha, Sherif M

    2013-04-01

    Granisetron is a selective 5-HT3 receptor antagonist used in prevention and treatment of chemotherapy-induced nausea and vomiting. The drug is available in tablet dosage form and parenteral dosage form containing benzyl alcohol as a preservative. The main route of degradation of granisetron is through hydrolysis. The present work describes the development of a simple, rapid, and reliable first derivative spectrophotometric method for the determination of granisetron in presence of its hydrolytic products as well as the formulations adjuvant and benzyl alcohol. The method is based on the measurement of the first derivative response of granisetron at 290 nm where the interference of the hydrolytic products, the co-formulated adjuvant and benzyl alcohol is completely eliminated. The proposed method was validated with respect to specificity, linearity, selectivity, accuracy, precision, robustness, detection, and quantification limits. Regression analysis showed good correlation between the first derivative response and the concentration of granisetron over a range of 8-16 μg ml(-1) . Statistical analysis proved the accuracy of the proposed method compared with a reference stability indicating high performance liquid chromatography method. The described method was successfully applied to the determination of granisetron in different batches of tablets and ampoules. The assay results obtained in this study strongly encourage us to apply the validated method for the quality control and routine analysis of tablets and parenteral preparations containing granisetron. Copyright © 2012 John Wiley & Sons, Ltd.

  18. Speciative determination of total V and dissolved inorganic vanadium species in environmental waters by catalytic–kinetic spectrophotometric method

    Ramazan Gürkan

    2017-02-01

    Full Text Available A kinetic determination of V(V as a catalyst was spectrophotometrically performed by using the indicator reaction of Gallamine blue (GB+ and bromate at pH 2.0. The reaction was followed by measuring absorbance change for a fixed-time of 3 min at 537 nm. The variables such as reagent concentration, pH, buffer concentration, ionic strength and temperature were optimized to improve the selectivity and sensitivity. Under the optimized conditions, the determination of V(V was performed in the range 1–100 μg L−1 with limits of detection and quantification of 0.31 and 0.94 μg L−1. The developed kinetic method is sufficiently sensitive, selective and simple. It was successfully applied to the speciative determination of total V and inorganic dissolved vanadium species, V(V and V(IV in environmental water samples. The oxidizing property of permanganate is used to differentiate between V(IV and V(V species. The V(IV content was found by subtracting the V(V content from those of total V. The recovery is above 95% for V(V spiked samples. Additionally, the accuracy was validated by analysis of a certified water sample, CRM TMDA-53.3, and the results were in good agreement with the certified value.

  19. Multi-wavelength spectrophotometric determination of acidity constant of some newly synthesized Schiff bases and their QSPR study

    Hemmateenejad, Bahram; Emami, Leila; Sharghi, Hashem

    2010-01-01

    The acidity constants of some newly synthesized Schiff base derivatives were determined by hard-model based multivariate data analysis of the spectrophotometric data in the course of pH-metric titration in 50% (v/v) methanol-water binary solvent. The employed data analysis method was also able to extract the pure spectra and pH-dependent concentration profiles of the acid-base species. The molecules that possess different substituents (both electron donating and withdrawing) on the ortho-, meta- and para-positions of one of the phenyl ring showed variable acidity constants ranging from 8.77 to 11.07 whereas the parent molecule had an acidity constant of 10.25. To investigate the quantitative effects of changing of substitution pattern on the acidity constant, a quantitative structure-property relation analysis was conducted using substituent constants and molecular descriptor. Some models with high statistical quality (measured by cross-validation Q2) were obtained. It was found that the acidity constant of the studied molecules in the methanol-water mixed solvent not only is affected by electronic features of the solutes but also by the lipophilic interaction between methanol part of solvent and the deprotonated solutes.

  20. Separation of zirconium through extraction in hydrochloric medium with tri-n-octilamine and its spectrophotometric determination with chloroanilic acid

    Floh, B.; Abrao, A.; Federgruen, L.

    1976-01-01

    A procedure is outlined for the spectrophotometric determination of zirconium using its complex with chloroanilic acid in HC10 4 2M. Interfering elements like Fe, Zn, U, Cy, Cd, Sb, Co, Pb, Hg, Tl, Pt, Au, Pd, Ga, In, Mo and W are previously extracted with tri-n-octylamine 7,5%-benzene from 4 M HCL. Then, the acid content of the solution is ascertained to 10 M HCL and zirconium is extracted with the amine. Nb is a strong interference, being extracted by the amine as well as zirconium and absorbing at the same region as zirconium chloroanilate. Zirconium is stripped from the organic phase with Na 2 CO 3 . The colour development is done with chloroanilic acid in 2 M HC10 4 and the measurements at 340 nm. The method allows the determination of 5 micrograms of Zr. The work curve covers the 0.2 - 2.0 μg Zr/mL range. The procedure is being applied to the determination of zirconium in several alloys and in samples containing zinc, magnesium, iron, aluminium, uranium and thorium [pt

  1. Novel atomic absorption spectrometric and rapid spectrophotometric methods for the quantitation of paracetamol in saliva: application to pharmacokinetic studies.

    Issa, M M; Nejem, R M; El-Abadla, N S; Al-Kholy, M; Saleh, Akila A

    2008-01-01

    A novel atomic absorption spectrometric method and two highly sensitive spectrophotometric methods were developed for the determination of paracetamol. These techniques based on the oxidation of paracetamol by iron (III) (method I); oxidation of p-aminophenol after the hydrolysis of paracetamol (method II). Iron (II) then reacts with potassium ferricyanide to form Prussian blue color with a maximum absorbance at 700 nm. The atomic absorption method was accomplished by extracting the excess iron (III) in method II and aspirates the aqueous layer into air-acetylene flame to measure the absorbance of iron (II) at 302.1 nm. The reactions have been spectrometrically evaluated to attain optimum experimental conditions. Linear responses were exhibited over the ranges 1.0-10, 0.2-2.0 and 0.1-1.0 mug/ml for method I, method II and atomic absorption spectrometric method, respectively. A high sensitivity is recorded for the proposed methods I and II and atomic absorption spectrometric method value indicate: 0.05, 0.022 and 0.012 mug/ml, respectively. The limit of quantitation of paracetamol by method II and atomic absorption spectrometric method were 0.20 and 0.10 mug/ml. Method II and the atomic absorption spectrometric method were applied to demonstrate a pharmacokinetic study by means of salivary samples in normal volunteers who received 1.0 g paracetamol. Intra and inter-day precision did not exceed 6.9%.

  2. A continuous spectrophotometric assay for monitoring adenosine 5'-monophosphate production.

    First, Eric A

    2015-08-15

    A number of biologically important enzymes release adenosine 5'-monophosphate (AMP) as a product, including aminoacyl-tRNA synthetases, cyclic AMP (cAMP) phosphodiesterases, ubiquitin and ubiquitin-like ligases, DNA ligases, coenzyme A (CoA) ligases, polyA deadenylases, and ribonucleases. In contrast to the abundance of assays available for monitoring the conversion of adenosine 5'-triphosphate (ATP) to ADP, there are relatively few assays for monitoring the conversion of ATP (or cAMP) to AMP. In this article, we describe a homogeneous assay that continuously monitors the production of AMP. Specifically, we have coupled the conversion of AMP to inosine 5'-monophosphate (IMP) (by AMP deaminase) to the oxidation of IMP (by IMP dehydrogenase). This results in the reduction of oxidized nicotine adenine dinucleotide (NAD(+)) to reduced nicotine adenine dinucleotide (NADH), allowing AMP formation to be monitored by the change in the absorbance at 340 nm. Changes in AMP concentrations of 5 μM or more can be reliably detected. The ease of use and relatively low expense make the AMP assay suitable for both high-throughput screening and kinetic analyses. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Development of Spectrophotometric Process Monitors for Aqueous Reprocessing Facilities

    Smith, N.; Krebs, J.; Hebden, A.

    2015-01-01

    The safeguards envelope of an aqueous reprocessing plant can be extended beyond traditional measures to include surveillance of the process chemistry itself. By observing the concentration of accountable species in solution directly, a measure of real time accountancy can be applied. Of equal importance, select information on the process chemistry can be determined that will allow the operator and inspectors to verify that the process is operating as intended. One of the process monitors that can be incorporated is molecular spectroscopy, such as UV-Visible absorption spectroscopy. Argonne National Laboratory has developed a process monitoring system that can be tailored to meet the specific chemistry requirements of a variety of processes. The Argonne Spectroscopic Process monitoring system (ASP) is composed of commercial-off-the-shelf (COTS) spectroscopic hardware, custom manufactured sample handling components (to meet end user requirements) and the custom Plutonium and Uranium Measurement and Acquisition System (PUMAS) software. Two versions of the system have been deployed at the Savannah River Site's H-Canyon facility, tailored for high and low concentration streams. (author)

  4. The spatial concentration of dust emissions measured by using 3D scanning lidar in the open storage yards of steel-making company

    Chiang, Chih-Wei; Chiang, Hong-Wei; Chou, Huann-Ming; Sun, Shu-Huang; Lee, Jiann-Shen

    2017-06-01

    The wind-blown dust emissions frequently occur in the open storage yards of steel-making companies. Tracking the dust source and monitoring their dispersion are rather difficult. This type of open-air storage yards poses many environmental hazards. The 3-D scanning lidar system is effective in environmental monitoring (e.g., dust) with high temporal and spatial resolution, which is lacking in traditional ground-based measurement. The objective of this paper is to make an attempt for the flux estimation of dust concentration by using lidar system. Further, we investigate the dynamical process of dust and their relationship with local air quality monitoring data. The results show that the material storage erosion by wind ( 3.6 m/s) could cause dust to elevate up to 20m height above the material storage, and produces the flux of dust around 674 mg/s. The flux of dust is proportional to the dust mass concentration (PM10) measured by commercial ambient particular monitors.

  5. Spectrophotometric Determination of Carbon Disulphide in the Workplace Air

    V. Pitschmann

    2013-01-01

    Full Text Available This papre describes a simple method of carbon disulphide determination in the air of working environment in the chemical companies and plants after its absorption into aprotic N,N-dimethylformamide solvent. Carbon disulphide absorbed into aprotic solvent was transformed by using ammonium hydroxide on sulphides which were determined by spectrophotometry. 5,5′-Dithiobis(2-nitrobenzoic acid and blue tetrazolium chloride were used as chromogenic sensing reagents. Colour-reducing products were measured at the wavelength of 500, respectively 520 nm. Detection limits for determination of carbon disulphide in the air are 0.2, respectively 0.4 mg·m−3.

  6. Flow injection determination of metronidazole through spectrophotometric measurement of the nitrite ion produced upon alkaline hydrolysis

    Simões Simone S.

    2006-01-01

    Full Text Available A new method for metronidazole determination, based on spectrometric monitoring of a diazonium salt produced in-line by alkaline hydrolysis released nitrite ions, was developed and successfully applied to pharmaceutical tablets (r = 0.9993, 2.0-20.0 mg L-1, DL = 0.7 mg L-1 with no interference from common ingredients accompanying the drug.

  7. Spectrophotometric determination of microamounts of boron in water

    Weber de D'Alessio, Ana; Guido, O.O.; Bandin, N.A.

    1980-01-01

    A fast method of boron in water determination has been studied for the 0.5 .- 2 μg ml -1 concentration range. The procedure is based on the formation of a coloured complex of the tetrafluoroborate of a thionine derivate cation, its extraction by an organic solvent and the further absorptiometric measurement in such media. Methylene blue and azur C were comparatively tested as organic reagents, with 1.2-dichloroethane as the extractant. The absorbance was measured at the maximum (658 nm). The tetrafluoroboric acid formation was reached in 20 min on a water-bath kept at 60 deg C. The sensitivity with methylene blue was higher than with azur C. The molar absorptivities were 65,000 and 38,000 (l mol -1 cm -1 ) respectively. For a boron concentration of 0.1 μg ml -1 the relative standard deviation was 9% for methylene blue and 7% for azur C. The procedure is applicable to the control of boron traces in heavy water of nuclear reactors refrigerating loops. (author) [es

  8. Thin layer alanine dosimeter with optical spectrophotometric evaluation

    Zagorski, Z.P.

    2000-01-01

    Experience in the high dose dosimetry of gamma radiation, gathered in our group from the sixties till now, allows to express the opinion, that techniques applied are adequate to solve problems. It can be confirmed by the fact that 60% of laboratories participating in the international comparison during the duration of the contract obtained satisfactory results. Adaptation of these methods, in particular of the alanine-ESR dosimetry to highly inhomogeneous fields of EB gives poor results, as it has been shown on thin films of the alanine/polymer composite. However, the applications of these films give excellent results if the concentration of the radical CH 3 C·H CO 2 - is measured by diffuse reflection spectrophotometry, which tolerates poor transparency of the composite and is insensitive to the orientation of crystals of alanine in thin films, what is disqualifying the ESR measurements. The development of thin-film dosimeters for EB processing was possible due to new developments in solid state radiation chemistry. The research has revealed some unsolved questions, e.g. of the high temperature coefficient of alanine based dosimeters, of the role of the size of spurs and the necessity to adapt dosimetry to the energy spectrum of electrons, because every type of accelerators differs in that respect. (author)

  9. Utilization of a Green Brominating Agent for the Spectrophotometric Determination of Pipazethate HCl in Pure Form and Pharmaceutical Preparations

    Ayman A. Gouda

    2013-01-01

    Full Text Available Five simple, accurate, and sensitive spectrophotometric methods (A–E have been described for the indirect assay of pipazethate HCl (PZT either in pure form or in pharmaceutical preparations. The proposed methods are based on the bromination of pipazethate HCl with a solution of excess bromate-bromide mixture in hydrochloric acid medium and subsequent estimation of the residual bromine by different reaction schemes. In the first three methods (A–C, the determination of the residual bromine is based on its ability to bleach the color of methyl orange, indigo carmine, or thymol blue dyes and measuring the absorbance at 520, 610, and 550 nm for methods A, B, and C, respectively. Methods D and E involves treating the unreacted bromine with a measured excess of iron(II, and the remaining iron(II is complexed with 1,10-phenanthroline, and the increase in absorbance is measured at 510 nm for method D and the resulting iron(III is complexed with thiocyanate and the absorbance is measured at 480 nm for method E. The different experimental parameters affecting the development and stability of the color are carefully studied and optimized. Regression analysis of the Beer-Lambert plots showed good correlation in the concentration ranges of 0.5–8.0 μg . The apparent molar absorptivity, Sandell's sensitivity, detection and quantitation limits were evaluated. The proposed methods have been applied and validated successfully for the analysis of the drug in its pure form and pharmaceutical formulations with mean recoveries of 99.94%–100.15% and relative standard deviation ≤1.53. No interference was observed from a common pharmaceutical adjuvant. Statistical comparison of the results with the reference method shows excellent agreement and indicates no significant difference in accuracy and precision.

  10. Application of hydrocyanic acid vapor generation via focused microwave radiation to the preparation of industrial effluent samples prior to free and total cyanide determinations by spectrophotometric flow injection analysis.

    Quaresma, Maria Cristina Baptista; de Carvalho, Maria de Fátima Batista; Meirelles, Francis Assis; Santiago, Vânia Maria Junqueira; Santelli, Ricardo Erthal

    2007-02-01

    A sample preparation procedure for the quantitative determination of free and total cyanides in industrial effluents has been developed that involves hydrocyanic acid vapor generation via focused microwave radiation. Hydrocyanic acid vapor was generated from free cyanides using only 5 min of irradiation time (90 W power) and a purge time of 5 min. The HCN generated was absorbed into an accepting NaOH solution using very simple glassware apparatus that was appropriate for the microwave oven cavity. After that, the cyanide concentration was determined within 90 s using a well-known spectrophotometric flow injection analysis system. Total cyanide analysis required 15 min irradiation time (90 W power), as well as chemical conditions such as the presence of EDTA-acetate buffer solution or ascorbic acid, depending on the effluent to be analyzed (petroleum refinery or electroplating effluents, respectively). The detection limit was 0.018 mg CN l(-1) (quantification limit of 0.05 mg CN l(-1)), and the measured RSD was better than 8% for ten independent analyses of effluent samples (1.4 mg l(-1) cyanide). The accuracy of the procedure was assessed via analyte spiking (with free and complex cyanides) and by performing an independent sample analysis based on the standard methodology recommended by the APHA for comparison. The sample preparation procedure takes only 10 min for free and 20 min for total cyanide, making this procedure much faster than traditional methodologies (conventional heating and distillation), which are time-consuming (they require at least 1 h). Samples from oil (sour and stripping tower bottom waters) and electroplating effluents were analyzed successfully.

  11. Measuring $\

    Mitchell, Jessica Sarah [Univ. of Cambridge (United Kingdom)

    2011-01-01

    The MINOS Experiment consists of two steel-scintillator calorimeters, sampling the long baseline NuMI muon neutrino beam. It was designed to make a precise measurement of the ‘atmospheric’ neutrino mixing parameters, Δm2 atm. and sin2 (2 atm.). The Near Detector measures the initial spectrum of the neutrino beam 1km from the production target, and the Far Detector, at a distance of 735 km, measures the impact of oscillations in the neutrino energy spectrum. Work performed to validate the quality of the data collected by the Near Detector is presented as part of this thesis. This thesis primarily details the results of a vμ disappearance analysis, and presents a new sophisticated fitting software framework, which employs a maximum likelihood method to extract the best fit oscillation parameters. The software is entirely decoupled from the extrapolation procedure between the detectors, and is capable of fitting multiple event samples (defined by the selections applied) in parallel, and any combination of energy dependent and independent sources of systematic error. Two techniques to improve the sensitivity of the oscillation measurement were also developed. The inclusion of information on the energy resolution of the neutrino events results in a significant improvement in the allowed region for the oscillation parameters. The degree to which sin2 (2θ )= 1.0 could be disfavoured with the exposure of the current dataset if the true mixing angle was non-maximal, was also investigated, with an improved neutrino energy reconstruction for very low energy events. The best fit oscillation parameters, obtained by the fitting software and incorporating resolution information were: | Δm2| = 2.32+0.12 -0.08×10-3 eV2 and sin2 (2θ ) > 0.90(90% C.L.). The analysis provides the current world best measurement of the atmospheric neutrino mass

  12. Decision Making

    Pier Luigi Baldi

    2006-06-01

    Full Text Available This article points out some conditions which significantly exert an influence upon decision and compares decision making and problem solving as interconnected processes. Some strategies of decision making are also examined.

  13. Spectrophotometric study of bio-sorption of uranium on glass grade spodumene shell powder

    Parakudyil, A.S.; Pillai, A.K.; Reddy, A.V.R.; Singal, R.K.; Sharma, P.K.; Michael, K.M.

    2012-01-01

    Separation of uranium found in iron ore leachates was done by extraction chromatography using glass grade spodumene shellpowder (GSS) in nitric acid medium and analyzed spectrophotometrically. The influences of metal ion concentration, pH and adsorption capacity of biomass were investigated. Biosorption is a potential method of separation of heavy and trace metals from waste water and effluents from various sources. The adsorption capacities of biomass were investigated by batch experiments and column experiments. In the present study, glass grade spodumene shell powder (GSS) in acidic medium is being used as a biosorbent

  14. K4 Fe(CN)6 as a spectrophotometric agent for uranium analysis

    Soedyartomo; Tarwita.

    1976-01-01

    The properties of K 4 Fe(CN) 6 as a spectrophotometric agent for Uranium analysis was observed by putting some experiment into practice. The experiment covers the observation of expanding colour stability, the optimization of operating condition (p,H. and wavelength), the effect of K 4 Fe(CN) 6 concentration and the preparation of its standard curves (transmitansion vs uranium concentration) and the observation of the interfering metal spectra s (Cu ++ , Fe ++ ) either of its mixtures or themselves alone, has been carried out. The result and discussion on it are given. (author)

  15. Comparison of numerical and physico-chemical models for on-line spectrophotometric control of uranium

    Corriou, J.P.; Boisde, G.

    1986-04-01

    In view of on-line spectrophotometric control of fuel reprocessing streams, a physico-chemical model able to predict uranium and nitric acid concentrations in an uranyl nitrate-nitric acid system has been searched. Thus the influences of the following parameters: uranium, nitrate, hydrogen ion concentrations, ionic strength, on the equilibria of complexation of uranium (VI) nitrate have been evaluated. Extinction coefficients for the uranium mononitrate and uranium dinitrate complexes are given between 410 and 440 nm. The apparent equilibrium constants are determined as a function of the ionic strength. The limitations of this predictive model are emphasized and comparisons with numerical models are discussed. (16 refs)

  16. Spectrophotometric determination of hydrogen peroxide with osmium(VIII) and m-carboxyphenylfluorone.

    Hoshino, Mitsuru; Kamino, Shinichiro; Doi, Mitsunobu; Takada, Shingo; Mitani, Shota; Yanagihara, Rika; Asano, Mamiko; Yamaguchi, Takako; Fujita, Yoshikazu

    2014-01-03

    Spectrophotometric determination of hydrogen peroxide was accomplished with osmium(VIII) and m-carboxyphenylfluorone (MCPF) in the presence of cetyltrimethylammonium chloride (CTAC). In the determination of hydrogen peroxide based on the fading of the color of osmium(VIII)-MCPF complex, Beer's law was obeyed in the range 20-406 ng mL(-1), with an effective molar absorption coefficient (at 580 nm) of 5.21×10(4) L mol(-1) cm(-1) and a relative standard deviation of 0.33% (n=6). Further, we performed the characterization of MCPF and obtained the crystal structure. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Ultra-violet Spectrophotometric Determination of Caffeine in Soft and Energy Drinks Available in Yenagoa, Nigeria

    Amos-Tautua; W. Bamidele Martin; E.R.E. Diepreye

    2014-01-01

    This study was carried out to determine the pH and levels of caffeine in eight brands of carbonated and energy drinks available in local market in Yenagoa, Nigeria. Quantitative analysis of caffeine was performed by a simple and fast standard UV spectrophotometric method, using carbon tetrachloride as the extracting solvent. Results showed that the pH of the beverages were slightly acidic ranging from 5.92-6.44. The minimum caffeine level was observed in the carbonated soft drink Coca Cola (4...

  18. Development of a new spectrophotometric method to determine the total aromatic contents in kerosene

    Harfoush, A.; shlewit, H.

    1996-12-01

    This developed spectrophotometric method is helpful to determine and control the total aromatic contents in kerosene, during the treatment process of kerosene with conc. H sup 2 SO sup 4 and P sup 2 O sup 5 to remove aromatics, which have negative effect on the solvent extraction coefficient KD of uranium from the Syrian phosphoric acid, where kerosene is used as diluent. this method is rapid according to others, and simply, using the standard curve prepared by the separated aromatics from the Syrian kerosene, A =f (C) at 272 nm, we can calculate the aromatic contents in the known samples. (author). 24 Refs., 5 Figs

  19. Anion-exchange enrichment and spectrophotometric determination of uranium in sea-water

    Kuroda, Rokuro; Oguma, Koichi; Mukai, Noriko; Iwamoto, Masatoshi

    1987-01-01

    A method is proposed for the determination of uranium in sea-water. The uranium is strongly sorbed on a strongly basic anion-exchange resin (Cl - form) from acidified sea-water containing sodium azide (0.3M) and is easily eluted with 1M hydrochloric acid. Uranium in the effluent can be determined spectrophotometrically with Arsenazo III. The combined method allows easy and selective determination of uranium in sea-water without using a sophisticated adsorbent. The overall recovery and precision are satisfactory at the 3 μg/1. level. (author)

  20. Spectrophotometric activity microassay for pure and recombinant cytochrome P450-type nitric oxide reductase

    Garny, S

    2014-02-01

    Full Text Available spectrophotometric quantification of NADH [19]. Kaya et al. (2004) [19] demonstrated the linearly proportional relationship between the oxidation of NADH to NAD+, with the release of NO from NOC-5, but did not develop a kinetic assay for NOR activity using... this principle, the primary aim of this study. Nakahara et al. (1993) [10] determined the stoichiometry of NO reduction by NOR as 2:1:1 for NO:NADH:N2O. Therefore, for each NADH oxidized to NAD+, two molecules of NO are converted to N2O (refer Equation 1). 2...

  1. Oxytetracycline as a new analytical reagent for the spectrophotometric determination of boron

    Narayana, G L

    1984-05-01

    Oxytetracycline hydrochloride, Terramycin, is introduced as a new reagent for the spectrophotometric determination of trace quantities of boron in concentrated sulphuric acid medium. The reagent has an absorption maximum at 430 nm, and that of the boron complex at 520 nm. The colored system conformed to Beer's law between 2 and 10 ..mu..g of boron at 520 nm. The molar absorptivity calculated on the basis of boron is 10,800 1 mol/sup -1/ cm/sup -1/. The composition of the complex has been shown to be 1:1 both by the slope ratio and molar ratio methods. 16 references.

  2. Oxytetracycline as a new analytical reagent for the spectrophotometric determination of boron

    Narayana, G.L.

    1984-01-01

    Oxytetracycline hydrochloride, Terramycin, is introduced as a new reagent for the spectrophotometric determination of trace quantities of boron in concentrated sulphuric acid medium. The reagent has an absorption maximum at 430 nm, and that of the boron complex at 520 nm. The coloured system conformed to Beer's law between 2 and 10 μg of boron at 520 nm. The molar absorptivity calculated on the basis of boron is 10,800 1 mol -1 cm -1 . The composition of the complex has been shown to be 1:1 both by the slope ratio and molar ratio methods. (author)

  3. Liquid chromatographic and spectrophotometric methods for the determination of erythromycin stearate and trimethoprim in tablets

    Hassib, Sonia T.; Farag, Awatef E.; Elkady, Ehab F.

    2011-01-01

    Simple, accurate and precise reversed-phase liquid chromatographic (LC) and spectrophotometric methods have been developed and validated for the determination of erythromycin stearate (ERS) and trimethoprim (TMP) in mixture. In LC method, chromatographic separation was achieved on a Symmetry® Waters C18 column (150 × 4.6 mm, 5 μm) based on isocratic elution using a mobile phase consisting of potassium dihydrogen phosphate buffer pH (9):acetonitrile:water (25:100:50, v/v/v) at a flow rate of 1...

  4. Spectrophotometric determination of phosphorus in iron alloys employing a flow injection system

    Gervasio,Ana P. G.; Miranda,Carlos E. S.; Luca,Gilmara C.; Tumang,Cristiane A.; Campos,Luis F. P.; Reis,Boaventura F.

    2001-01-01

    A flow-injection procedure for spectrophotometric determination of phosphorus in electrolytic iron and iron alloys is proposed. The method is based on the ammonium molybdate reaction followed by stannous chloride reduction in acidic medium. In order to circumvent the severe interference caused by the major constituents such as Fe(III) and Cr(III), a mini-column packed with AG50W-X8 resin was coupled to the manifold. A sample throughput of 40 determinations per hour, a dynamical range from P 0...

  5. Potentiometric and spectrophotometric titration study of interaction of tungstovanadophosphoric heteropolyacids with sodium hydroxide

    Borkoyakov, S.A.; Fisun, L.A.

    1988-01-01

    The methods of potentiometric and spectrophotometric titration are used to study H s+n PW 12-n V n O 40 (n=1,2) (P-W-V HPA) decomposition by sodium hydroxide. It is shown that at the first stage of heteropolyanion interaction with alkali (pH) > 4 P-W-V HPA structural reconstruction takes place. It is accompanied by the formation of complexes with a higher content of vanadium atoms stable at pH 4-7/ P-W-V HPA decomposition to initial salts occurs at pH > 8

  6. Spectrophotometric observations of very low ionization HII regions in the LMC

    Pena, M.; Ruiz, M.T.; Rubio, M.

    1987-01-01

    Optical spectrophotometric observations of 17 very low ionization HII regions of the LMC are reported. Physical conditions and chemical composition of these objects are derived from the emission line intensities. The average chemical abundances obtained are: log O/H=8.49+-0.08, log N/H=6.91+-0.07 and log S/H=6.89+-0.10. We do not find evidence of any composition gradient in the LMC. The HII regions in the vicinity of the detected molecular cloud complexes show higher nebular reddening. (Author)

  7. Comparative study on the selectivity of various spectrophotometric techniques for the determination of binary mixture of fenbendazole and rafoxanide.

    Saad, Ahmed S; Attia, Ali K; Alaraki, Manal S; Elzanfaly, Eman S

    2015-11-05

    Five different spectrophotometric methods were applied for simultaneous determination of fenbendazole and rafoxanide in their binary mixture; namely first derivative, derivative ratio, ratio difference, dual wavelength and H-point standard addition spectrophotometric methods. Different factors affecting each of the applied spectrophotometric methods were studied and the selectivity of the applied methods was compared. The applied methods were validated as per the ICH guidelines and good accuracy; specificity and precision were proven within the concentration range of 5-50 μg/mL for both drugs. Statistical analysis using one-way ANOVA proved no significant differences among the proposed methods for the determination of the two drugs. The proposed methods successfully determined both drugs in laboratory prepared and commercially available binary mixtures, and were found applicable for the routine analysis in quality control laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Spectrophotometric determination of rare earths in binary mixtures

    Krasnova, A.V.; Shvarev, V.S.

    1978-01-01

    The possibility was investigated of using the reaction with brompyrogallol red (BPR) (dibrompyrogallosulfophthalein) for analyzing binary mixtures of rare earth metals close in ordinal numbers (La-Y, La-Eu, La-Sm, La-Nd, Nd-Y, Nd-Eu). Heavy REM are masked by nitrile-acetic acid (NAA). The experimental design method was used to determine optimum conditions. The optimizing parameters were the optical density measured with respect to water and the amount of the component bound into the complex. It was found that optimum conditions for the analysis of investigated mixtures differ only in the amount of NAA necessary to mask the heavy element [NAA]/[Sm 3+ ]=4; [NAA]/[Eu 3+ ]=5; [NAA]/Nb 3+ ]=10; [NAA]/[Y 3+ ]=2.5. The optimum acidity and the amount of BPR are always the same: pH 6.5; [BPR]/[La 3+ ]=[BPR]/[Nd 3+ ]=4. The given method for analyzing binary mixtures of lanthanoids surpasses considerably in sensitivity the methods based on intrinsic absorption spectra, while retaining the same reproducibility

  9. Irradiation temperature effect on glutamine (spectrophotometric readout) dosimeter

    Gupta, B.L.; Narayan, G.R.; Nilekani, S.R.; Bhat, R.M.

    2001-01-01

    For the dose estimation using glutamine dosimeter, 20 mg L-glutamine powder is dissolved in 10 ml of a solution which contains 2x10 -3 mol dm -3 ferrous ammonium sulphate and 10 -4 mol dm -3 xylenol orange in aerated aqueous 0.033 mol dm -3 sulphuric acid (FX). The plot of absorbance at 549 nm against dose is non-linear, however, the plot of 1/absorbance vs. 1/dose is linear. The slope of this linear plot changes above an absorbance of 0.3 corresponding to a dose of about 15 kGy. The response of the dosimeter is independent of irradiation temperature in the temperature range of 23-30 deg. C within the uncertainty of dose measurement. Below 23 deg. C, the absorbance decreases by 1.23% per deg. sign C decrease in temperature while between 30 and 40 deg. C, the absorbance increases by 0.75% per deg. C increase in temperature. Above 40 deg. C, the absorbance increases by 0.2% per deg. C only. The absorbance is corrected for the irradiation temperature and the dose is read from a calibration graph at 25 deg. C. Either a linear or polynomial relation can be used for the dose calculation

  10. Kinetic spectrophotometric determination of ethamsylate in dosage forms.

    El-Enany, Nahed; Belal, Fathalla; Rizk, Mohamed

    2007-01-01

    A simple and sensitive kinetic method has been developed for the determination of ethamsylate (ESL) in its pharmaceutical preparations. The method is based upon oxidation of ESL with 3-methyl-2-benzothiazolinone hydrazone hydrochloride in presence of cerium (IV) ammonium sulfate at room temperature for 20 min. The absorbance of the reaction product is measured at 514 nm. The absorbance-concentration plot was rectilinear over the range of 4-30 microg/mL (r = 0.9999). The lower detection limit was 0.267 microl/mL (9.110 x 10(-6) M) and the lower quantitation limit was 0.808 microg/mL. The different experimental parameters affecting the development and stability of the reaction product were studied and optimized. The proposed method was applied to the determination of ESL in formulations, and the results obtained were in good agreement with those obtained using a reference method. The proposed method was also used for the in vitro detection of ESL in spiked human plasma at its therapeutic concentration level.

  11. [Adapting and validating the generic instrument CollaboRATE™ to measure women's participation in health related decision-making during the reproductive process].

    Bravo, Paulina; Contreras, Aixa; Dois, Angelina; Villarroel, Luis

    2018-05-01

    There is a worldwide interest in involving patients in health related decisions, so patients can actively search for therapeutic options and choose course of action that allows them to have better quality of life and wellbeing. The majority of the instruments available to capture the degree of participation in medical decision-making are in English and have been developed in high income countries. To adapt and validate for the Chilean context the instrument CollaboRATE™, to measure women's participation in medical decisions during the reproductive process. Cross-sectional study to adapt and validate the instrument CollaboRATE™. Maternity units in Santiago, Chile. Puerperal women in maternity units of three public hospitals. Translation and back-translation, cultural and linguistic relevance with service users and final revision by experts. Study for validation with 90 puerperal women. The Chilean version of CollaboRATE™ demonstrated to be a reliable instrument to capture the degree of patients' participation in medical decision-making. Cronbach alpha was above 0.89. This study provides the first instrument to capture the prevalence of SDM in a Latin American country. This instrument will be critical in future research efforts that seek to explore to what extent people are being involved in the decisions related to their healthcare. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  12. High-sucrose diets in male rats disrupt aspects of decision making tasks, motivation and spatial memory, but not impulsivity measured by operant delay-discounting.

    Wong, Alanna; Dogra, Vimi R; Reichelt, Amy C

    2017-06-01

    Excessive consumption of sugar sweetened drinks is proposed to produce functional changes in the hippocampus and prefrontal cortex, leading to perturbations in behavioural control. Impairments in behavioural control have been observed in obese people on tasks that involve making choices, including delay-discounting, indicative of increased impulsivity. In this study we examined the impact of 2h daily access to 10% sucrose (or no sucrose in controls) in young male rats on behavioural tasks reliant on hippocampal function including delay-discounting, T-maze forced choice alternation and place recognition memory, as well as progressive ratio to measure motivation. We observed deficits in place recognition memory and T-maze forced choice alternation, indicative of hippocampal deficits in rats with a history of sucrose consumption. Moreover, rats with a history of sucrose consumption were less motivated to lever press for rewards on a progressive ratio schedule. However, rats with a history of sucrose consumption performed equally to control animals during the delay-discounting task, suggesting that they discounted for reward size over a delay in a manner comparable to control animals. These findings indicate that high-sucrose diets impact on spatial and working memory processes, but do not induce impulsive-like choice behaviours in rats, suggesting that unhealthy diet choices may not influence this aspect of decision-making behaviour. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. SDSS-IV/MaNGA: SPECTROPHOTOMETRIC CALIBRATION TECHNIQUE

    Yan, Renbin; Sánchez-Gallego, José R. [Department of Physics and Astronomy, University of Kentucky, 505 Rose St., Lexington, KY 40506-0057 (United States); Tremonti, Christy; Bershady, Matthew A.; Eigenbrot, Arthur; Wake, David A. [Department of Astronomy, University of Winsconsin-Madison, 475 N. Charter Street, Madison, WI 53706-1582 (United States); Law, David R. [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Schlegel, David J. [Physics Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720-8160 (United States); Bundy, Kevin [Kavli IPMU (WPI), UTIAS, The University of Tokyo, Kashiwa, Chiba 277-8583 (Japan); Drory, Niv [McDonald Observatory, Department of Astronomy, University of Texas at Austin, 1 University Station, Austin, TX 78712-0259 (United States); MacDonald, Nicholas [Department of Astronomy, Box 351580, University of Washington, Seattle, WA 98195 (United States); Bizyaev, Dmitry [Apache Point Observatory, P.O. Box 59, sunspot, NM 88349 (United States); Blanc, Guillermo A. [Departamento de Astronomía, Universidad de Chile, Camino el Observatorio 1515, Las Condes, Santiago (Chile); Blanton, Michael R.; Hogg, David W. [Center for Cosmology and Particle Physics, Department of Physics, New York University, 4 Washington Place, New York, NY 10003 (United States); Cherinka, Brian [Dunlap Institute for Astronomy and Astrophysics, University of Toronto, 50 St. George Street, Toronto, Ontario M5S 3H4 (Canada); Gunn, James E. [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States); Harding, Paul [Department of Astronomy, Case Western Reserve University, Cleveland, OH 44106 (United States); Sánchez, Sebastian F., E-mail: yanrenbin@uky.edu [Instituto de Astronomia, Universidad Nacional Autonoma de Mexico, A.P. 70-264, 04510 Mexico D.F. (Mexico); and others

    2016-01-15

    Mapping Nearby Galaxies at Apache Point Observatory (MaNGA), one of three core programs in the Sloan Digital Sky Survey-IV, is an integral-field spectroscopic survey of roughly 10,000 nearby galaxies. It employs dithered observations using 17 hexagonal bundles of 2″ fibers to obtain resolved spectroscopy over a wide wavelength range of 3600–10300 Å. To map the internal variations within each galaxy, we need to perform accurate spectral surface photometry, which is to calibrate the specific intensity at every spatial location sampled by each individual aperture element of the integral field unit. The calibration must correct only for the flux loss due to atmospheric throughput and the instrument response, but not for losses due to the finite geometry of the fiber aperture. This requires the use of standard star measurements to strictly separate these two flux loss factors (throughput versus geometry), a difficult challenge with standard single-fiber spectroscopy techniques due to various practical limitations. Therefore, we developed a technique for spectral surface photometry using multiple small fiber-bundles targeting standard stars simultaneously with galaxy observations. We discuss the principles of our approach and how they compare to previous efforts, and we demonstrate the precision and accuracy achieved. MaNGA's relative calibration between the wavelengths of Hα and Hβ has an rms of 1.7%, while that between [N ii] λ6583 and [O ii] λ3727 has an rms of 4.7%. Using extinction-corrected star formation rates and gas-phase metallicities as an illustration, this level of precision guarantees that flux calibration errors will be sub-dominant when estimating these quantities. The absolute calibration is better than 5% for more than 89% of MaNGA's wavelength range.

  14. SDSS-IV/MaNGA: SPECTROPHOTOMETRIC CALIBRATION TECHNIQUE

    Yan, Renbin; Sánchez-Gallego, José R.; Tremonti, Christy; Bershady, Matthew A.; Eigenbrot, Arthur; Wake, David A.; Law, David R.; Schlegel, David J.; Bundy, Kevin; Drory, Niv; MacDonald, Nicholas; Bizyaev, Dmitry; Blanc, Guillermo A.; Blanton, Michael R.; Hogg, David W.; Cherinka, Brian; Gunn, James E.; Harding, Paul; Sánchez, Sebastian F.

    2016-01-01

    Mapping Nearby Galaxies at Apache Point Observatory (MaNGA), one of three core programs in the Sloan Digital Sky Survey-IV, is an integral-field spectroscopic survey of roughly 10,000 nearby galaxies. It employs dithered observations using 17 hexagonal bundles of 2″ fibers to obtain resolved spectroscopy over a wide wavelength range of 3600–10300 Å. To map the internal variations within each galaxy, we need to perform accurate spectral surface photometry, which is to calibrate the specific intensity at every spatial location sampled by each individual aperture element of the integral field unit. The calibration must correct only for the flux loss due to atmospheric throughput and the instrument response, but not for losses due to the finite geometry of the fiber aperture. This requires the use of standard star measurements to strictly separate these two flux loss factors (throughput versus geometry), a difficult challenge with standard single-fiber spectroscopy techniques due to various practical limitations. Therefore, we developed a technique for spectral surface photometry using multiple small fiber-bundles targeting standard stars simultaneously with galaxy observations. We discuss the principles of our approach and how they compare to previous efforts, and we demonstrate the precision and accuracy achieved. MaNGA's relative calibration between the wavelengths of Hα and Hβ has an rms of 1.7%, while that between [N ii] λ6583 and [O ii] λ3727 has an rms of 4.7%. Using extinction-corrected star formation rates and gas-phase metallicities as an illustration, this level of precision guarantees that flux calibration errors will be sub-dominant when estimating these quantities. The absolute calibration is better than 5% for more than 89% of MaNGA's wavelength range

  15. Spectrophotometric determination of ethionamide in pharmaceuticals using Folin–Ciocalteu reagent and iron(III-ferricyanide as chromogenic agents

    Nagib A.S. Qarah

    2017-09-01

    Full Text Available Two simple and sensitive spectrophotometric methods are described for the determination of ethionamide (ETM in pure drug and tablets. The first method is based on the reduction of Folin–Ciocalteu (F–C reagent by ETM in sodium carbonate medium to form a blue coloured complex, which was measured at 760 nm (Molybdenum–tungsten blue method. In the second method (Prussian blue method, iron(III was reduced to iron(II by ETM in HCl medium, in which iron(II was complexed with ferricyanide, and the resulting Prussian blue was also measured at 760 nm. The absorbance measured in each case was related to the ETM concentration. The experimental conditions were carefully studied and optimised. Beer's law was obeyed in concentration ranges of 1–40 μg/ml and 0.2–4.0 μg/ml with the Molybdenum-tungsten blue method and the Prussian blue method, respectively, with corresponding molar absorptivity values of 5.72 × 103 and 3.18 × 104 l/(mol·cm. The limits of detection (LOD and quantification (LOQ were 0.09 and 0.27 μg/ml for the Molybdenum-tungsten blue method and 0.01 and 0.04 μg/ml for the Prussian blue method. Within-day and between-day relative standard deviations (%RSD at three different concentration levels were <3%, and the respective relative errors (%RE were ≤2%, implying good accuracy and precision of the methods. The proposed methods were successfully applied to the determination of ETM in bulk powder and tablets, and the results demonstrated that the methods were as accurate and precise as the official method.

  16. [Shared decision-making and individualized goal setting - a pilot trial using PRISM (Pictorial Representation of Illness and Self Measure) in psychiatric inpatients].

    Büchi, S; Straub, S; Schwager, U

    2010-12-01

    Although there is much talk about shared decision making and individualized goal setting, there is a lack of knowledge and knowhow in their realization in daily clinical practice. There is a lack in tools for easy applicable tools to ameliorate person-centred individualized goal setting processes. In three selected psychiatric inpatients the semistructured, theory driven use of PRISM (Pictorial Representation of Illness and Self Measure) in patients with complex psychiatric problems is presented and discussed. PRISM sustains a person-centred individualized process of goal setting and treatment and reinforces the active participation of patients. The process of visualisation and synchronous documentation is validated positively by patients and clinicians. The visual goal setting requires 30 to 45 minutes. In patients with complex psychiatric illness PRISM was used successfully to ameliorate individual goal setting. Specific effects of PRISM-visualisation are actually evaluated in a randomized controlled trial.

  17. Development and Validation of Spectrophotometric Methods for the Determination of Rasagiline in Pharmaceutical Preparations

    Serife Evrim Kepekci Tekkeli

    2013-01-01

    Full Text Available This study presents three simple, rapid, and accurate spectrophotometric methods for the determination of Rasagiline (RSG in pharmaceutical preparations. The determination procedures depend on the reaction of RSG with chloranilic acid for method A, tetrachloro-1,4-benzoquinone for method B, and 7,7,8,8-tetracyanoquinodimethane for method C. The colored products were quantitated spectrophotometrically at 524, 535, and 843 nm for methods A, B, and C, respectively. Different variables affecting the reaction were optimized. Linearity ranges of the methods with good correlation coefficients (0.9988–0.9996 were observed as 25–300 µg mL−1, 25–350 µg mL−1, and 50–500 µg mL−1 for methods A, B, and C, respectively. The formation of products takes place through different mechanisms. The sites of interaction were confirmed by elemental analysis using IR and 1H-NMR spectroscopy. The validation of the methods was carried out in terms of specificity, linearity, accuracy, precision, robustness, limit of detection, and limit of quantitation. No interference was observed from concomitants usually present in dosage forms. The methods were applied successfully to the determination of RSG in pharmaceutical preparations.

  18. Stopped-flow injection spectrophotometric method for determination of chlorate in soil

    Jaroon Jakmunee

    2008-06-01

    Full Text Available A stopped-flow injection (FI spectrophotometric procedure based on iodometric reaction for the determination of chlorate has been developed. Standard/sample was injected into a stream of potassium iodide solution and then merged with a stream of hydrochloric acid solution to produce triiodide. By stopping the flow while the sample zone is being in a mixing coil, a slow reaction of chlorate with iodide in acidic medium was promoted to proceed with minimal dispersion of the triiodide product zone. When the flow started again, a concentrated product zone was pushed into a flow cell and a signal profile due to light absorption of the product was recorded. Employing a lab-built semi-automatic stopped-FI analyser, the analysis can be performed with higher degree of automation and low chemical consumption. Linear calibration graph in the range of 5-50 mg ClO3- L-1 was obtained, with detection limit of 1.4 mg ClO3- L-1. Relative standard deviation of 2.2% (30 mg ClO3- L-1, n=10 and sample throughput of about 20 h-1 were achieved. The system was applied to soil samples and validated by batch spectrophotometric and standard titrimetric methods.

  19. Spectrophotometric determination of trace and ultratrace levels of boron in silicon and chlorosilane samples

    Chen, J.S.; Lin, H.M.; Yang, M.H.

    1991-01-01

    Spectrophotometric methods for the determination of boron in the low μg/g and ng/g range in high-purity silicon and dichloro- and trichlorosilanes were investigated in detail. The procedures established involve dissolution of silicon samples and the hydrolyzed products of chlorosilane samples in hydrofluoric acid-containing reagents followed by evaporation of the silicon matrix as H 2 SiF 6 . The boron retained in the treated sample solution was then determined by a spectrophotometric method using carminic acid as a chromatic reagent. Special effort has been paid to the control of the analytical blank and reproducible determination of boron. The results indicate that addition of mannitol and proper control of the evaporation process are effective in preventing volatilization of boron during the evaporation of silicon matrix and can thus attain high recovery of boron and reproducible analysis. Through meticulous control of the analytical blank and experimental conditions, the limit of detection for boron determination with the established method can be as low as ng/g levels. Application of the methods to the determination of boron in various stages of purification of silicon and trichlorosilane as well as in borophosphosilicate film was conducted. (orig.)

  20. Determination of Nitrite and Nitrate in Natural Waters Using Flow Injection with Spectrophotometric Detection

    Yaqoob, M.; Nabi, A.

    2013-01-01

    A simple and sensitive flow injection spectrophotometric method is reported for the room temperature determination of nitrite and nitrate based on the Griess reaction and a copperised cadmium column for reduction of nitrate. Calibration graphs were linear over the range 2 - 1000 micro g N L /sup -1/ (R2 = 0.9997 and 0.9999, n = 9) with a limit of detection (3 s.d.) of 1.0 micro g N L and relative standard deviations (n = 10) of 0.9 and 1.2% for 50 micro g N L nitrite and nitrate respectively. The sample throughput was 50 h. The effect of reagent concentrations, physical parameters (flow rate, sample volume, reaction coil and copperised cadmium column length) and the potential interferences are reported. The effect of salinity on the blank and on the determination of nitrite and nitrate are also presented. The method was applied to natural waters (rainwater, freshwater and estuarine water) and the results for nitrite + nitrate (140 - 7310 micro g N L/sup -1/) were not significantly different (95% confidence interval) from results obtained using a segmented flow analyser reference method with spectrophotometric detection. (author)