WorldWideScience

Sample records for major control point

  1. Geodetic Control Points - Multi-State Control Point Database

    Data.gov (United States)

    NSGIC State | GIS Inventory — The Multi-State Control Point Database (MCPD) is a database of geodetic and mapping control covering Idaho and Montana. The control were submitted by registered land...

  2. Searching for the majority: algorithms of voluntary control.

    Directory of Open Access Journals (Sweden)

    Jin Fan

    Full Text Available Voluntary control of information processing is crucial to allocate resources and prioritize the processes that are most important under a given situation; the algorithms underlying such control, however, are often not clear. We investigated possible algorithms of control for the performance of the majority function, in which participants searched for and identified one of two alternative categories (left or right pointing arrows as composing the majority in each stimulus set. We manipulated the amount (set size of 1, 3, and 5 and content (ratio of left and right pointing arrows within a set of the inputs to test competing hypotheses regarding mental operations for information processing. Using a novel measure based on computational load, we found that reaction time was best predicted by a grouping search algorithm as compared to alternative algorithms (i.e., exhaustive or self-terminating search. The grouping search algorithm involves sampling and resampling of the inputs before a decision is reached. These findings highlight the importance of investigating the implications of voluntary control via algorithms of mental operations.

  3. Strike Point Control on EAST Using an Isoflux Control Method

    International Nuclear Information System (INIS)

    Xing Zhe; Xiao Bingjia; Luo Zhengping; Walker, M. L.; Humphreys, D. A.

    2015-01-01

    For the advanced tokamak, the particle deposition and thermal load on the divertor is a big challenge. By moving the strike points on divertor target plates, the position of particle deposition and thermal load can be shifted. We could adjust the Poloidal Field (PF) coil current to achieve the strike point position feedback control. Using isoflux control method, the strike point position can be controlled by controlling the X point position. On the basis of experimental data, we establish relational expressions between X point position and strike point position. Benchmark experiments are carried out to validate the correctness and robustness of the control methods. The strike point position is successfully controlled following our command in the EAST operation. (paper)

  4. Web-Based Learning Enhancements: Video Lectures through Voice-Over PowerPoint in a Majors-Level Biology Course

    Science.gov (United States)

    Lents, Nathan H.; Cifuentes, Oscar E.

    2009-01-01

    This study is an experimental introduction of web-based lecture delivery into a majors-level introductory biology course. Web-based delivery, achieved through the use of prerecorded Voice-Over PowerPoint video lectures, was introduced on a limited basis to an experimental section while a control group, with the same instructor, received standard…

  5. Accuracy assessment of minimum control points for UAV photography and georeferencing

    Science.gov (United States)

    Skarlatos, D.; Procopiou, E.; Stavrou, G.; Gregoriou, M.

    2013-08-01

    In recent years, Autonomous Unmanned Aerial Vehicles (AUAV) became popular among researchers across disciplines because they combine many advantages. One major application is monitoring and mapping. Their ability to fly beyond eye sight autonomously, collecting data over large areas whenever, wherever, makes them excellent platform for monitoring hazardous areas or disasters. In both cases rapid mapping is needed while human access isn't always a given. Indeed, current automatic processing of aerial photos using photogrammetry and computer vision algorithms allows for rapid orthophomap production and Digital Surface Model (DSM) generation, as tools for monitoring and damage assessment. In such cases, control point measurement using GPS is either impossible, or time consuming or costly. This work investigates accuracies that can be attained using few or none control points over areas of one square kilometer, in two test sites; a typical block and a corridor survey. On board GPS data logged during AUAV's flight are being used for direct georeferencing, while ground check points are being used for evaluation. In addition various control point layouts are being tested using bundle adjustment for accuracy evaluation. Results indicate that it is possible to use on board single frequency GPS for direct georeferencing in cases of disaster management or areas without easy access, or even over featureless areas. Due to large numbers of tie points in the bundle adjustment, horizontal accuracy can be fulfilled with a rather small number of control points, but vertical accuracy may not.

  6. Controllable resonant tunnelling through single-point potentials: A point triode

    International Nuclear Information System (INIS)

    Zolotaryuk, A.V.; Zolotaryuk, Yaroslav

    2015-01-01

    A zero-thickness limit of three-layer heterostructures under two bias voltages applied externally, where one of which is supposed to be a gate parameter, is studied. As a result, an effect of controllable resonant tunnelling of electrons through single-point potentials is shown to exist. Therefore the limiting structure may be termed a “point triode” and considered in the theory of point interactions as a new object. The simple limiting analytical expressions adequately describe the resonant behaviour in the transistor with realistic parameter values and thus one can conclude that the zero-range limit of multi-layer structures may be used in fabricating nanodevices. The difference between the resonant tunnelling across single-point potentials and the Fabry–Pérot interference effect is also emphasized. - Highlights: • The zero-thickness limit of three-layer heterostructures is described in terms of point interactions. • The effect of resonant tunnelling through these single-point potentials is established. • The resonant tunnelling is shown to be controlled by a gate voltage

  7. Do Nondomestic Undergraduates Choose a Major Field in Order to Maximize Grade Point Averages?

    Science.gov (United States)

    Bergman, Matthew E.; Fass-Holmes, Barry

    2016-01-01

    The authors investigated whether undergraduates attending an American West Coast public university who were not U.S. citizens (nondomestic) maximized their grade point averages (GPA) through their choice of major field. Multiple regression hierarchical linear modeling analyses showed that major field's effect size was small for these…

  8. Octopuses use a human-like strategy to control precise point-to-point arm movements.

    Science.gov (United States)

    Sumbre, Germán; Fiorito, Graziano; Flash, Tamar; Hochner, Binyamin

    2006-04-18

    One of the key problems in motor control is mastering or reducing the number of degrees of freedom (DOFs) through coordination. This problem is especially prominent with hyper-redundant limbs such as the extremely flexible arm of the octopus. Several strategies for simplifying these control problems have been suggested for human point-to-point arm movements. Despite the evolutionary gap and morphological differences, humans and octopuses evolved similar strategies when fetching food to the mouth. To achieve this precise point-to-point-task, octopus arms generate a quasi-articulated structure based on three dynamic joints. A rotational movement around these joints brings the object to the mouth . Here, we describe a peripheral neural mechanism-two waves of muscle activation propagate toward each other, and their collision point sets the medial-joint location. This is a remarkably simple mechanism for adjusting the length of the segments according to where the object is grasped. Furthermore, similar to certain human arm movements, kinematic invariants were observed at the joint level rather than at the end-effector level, suggesting intrinsic control coordination. The evolutionary convergence to similar geometrical and kinematic features suggests that a kinematically constrained articulated limb controlled at the level of joint space is the optimal solution for precise point-to-point movements.

  9. Device for dynamic switching of robot control points

    DEFF Research Database (Denmark)

    2015-01-01

    The invention comprises a system for switching between control points of a robotic system involving an industrial robot including a robot arm with a number of joints and provided with a tool interest point movable in a plurality of degrees of freedom.......The invention comprises a system for switching between control points of a robotic system involving an industrial robot including a robot arm with a number of joints and provided with a tool interest point movable in a plurality of degrees of freedom....

  10. Control Point Generated PLS - lines

    Data.gov (United States)

    Minnesota Department of Natural Resources — The Control Point Generated PLS layer contains line and polygon features to the 1/4 of 1/4 PLS section (approximately 40 acres) and government lot level. The layer...

  11. Control Point Generated PLS - polygons

    Data.gov (United States)

    Minnesota Department of Natural Resources — The Control Point Generated PLS layer contains line and polygon features to the 1/4 of 1/4 PLS section (approximately 40 acres) and government lot level. The layer...

  12. Geodetic Control Points - MO 2014 Springfield Benchmarks (SHP)

    Data.gov (United States)

    NSGIC State | GIS Inventory — Points that show set benchmark or survey control locations in the City of Springfield. Many of these points are PLS section corners and quarter corners. These points...

  13. Pointing control for LDR

    Science.gov (United States)

    Yam, Y.; Briggs, C.

    1988-01-01

    One important aspect of the LDR control problem is the possible excitations of structural modes due to random disturbances, mirror chopping, and slewing maneuvers. An analysis was performed to yield a first order estimate of the effects of such dynamic excitations. The analysis involved a study of slewing jitters, chopping jitters, disturbance responses, and pointing errors, making use of a simplified planar LDR model which describes the LDR dynamics on a plane perpendicular to the primary reflector. Briefly, the results indicate that the command slewing profile plays an important role in minimizing the resultant jitter, even to a level acceptable without any control action. An optimal profile should therefore be studied.

  14. Space Telescope Pointing Control System software

    Science.gov (United States)

    Dougherty, H.; Rodoni, C.; Rossini, R.; Tompetrini, K.; Nakashima, A.; Bradley, A.

    1982-01-01

    The Space Telescope Pointing Control System software is in the advanced development stage, having been tested on both the airbearing and the static simulator. The overall structure of the software is discussed, along with timing and sizing evaluations. The interaction between the controls analysts and software designer is described.

  15. Network based control point for UPnP QoS architecture

    DEFF Research Database (Denmark)

    Brewka, Lukasz Jerzy; Wessing, Henrik; Rossello Busquet, Ana

    2011-01-01

    Enabling coexistence of non-UPnP Devices in an UPnP QoS Architecture is an important issue that might have a major impact on the deployment and usability of UPnP in future home networks. The work presented here shows potential issues of placing non-UPnP Device in the network managed by UPnP QoS. We...... address this issue by extensions to the UPnP QoS Architecture that can prevent non-UPnP Devices from degrading the overall QoS level. The obtained results show that deploying Network Based Control Point service with efficient traffic classifier, improves significantly the end-to-end packet delay...

  16. Fixed Point Learning Based Intelligent Traffic Control System

    Science.gov (United States)

    Zongyao, Wang; Cong, Sui; Cheng, Shao

    2017-10-01

    Fixed point learning has become an important tool to analyse large scale distributed system such as urban traffic network. This paper presents a fixed point learning based intelligence traffic network control system. The system applies convergence property of fixed point theorem to optimize the traffic flow density. The intelligence traffic control system achieves maximum road resources usage by averaging traffic flow density among the traffic network. The intelligence traffic network control system is built based on decentralized structure and intelligence cooperation. No central control is needed to manage the system. The proposed system is simple, effective and feasible for practical use. The performance of the system is tested via theoretical proof and simulations. The results demonstrate that the system can effectively solve the traffic congestion problem and increase the vehicles average speed. It also proves that the system is flexible, reliable and feasible for practical use.

  17. Comparative Analysis of Maximum Power Point Tracking Controllers under Partial Shaded Conditions in a Photovoltaic System

    Directory of Open Access Journals (Sweden)

    R. Ramaprabha

    2015-06-01

    Full Text Available Mismatching effects due to partial shaded conditions are the major drawbacks existing in today’s photovoltaic (PV systems. These mismatch effects are greatly reduced in distributed PV system architecture where each panel is effectively decoupled from its neighboring panel. To obtain the optimal operation of the PV panels, maximum power point tracking (MPPT techniques are used. In partial shaded conditions, detecting the maximum operating point is difficult as the characteristic curves are complex with multiple peaks. In this paper, a neural network control technique is employed for MPPT. Detailed analyses were carried out on MPPT controllers in centralized and distributed architecture under partial shaded environments. The efficiency of the MPPT controllers and the effectiveness of the proposed control technique under partial shaded environments was examined using MATLAB software. The results were validated through experimentation.

  18. Washing and chilling as critical control points in pork slaughter hazard analysis and critical control point (HACCP) systems.

    Science.gov (United States)

    Bolton, D J; Pearce, R A; Sheridan, J J; Blair, I S; McDowell, D A; Harrington, D

    2002-01-01

    The aim of this research was to examine the effects of preslaughter washing, pre-evisceration washing, final carcass washing and chilling on final carcass quality and to evaluate these operations as possible critical control points (CCPs) within a pork slaughter hazard analysis and critical control point (HACCP) system. This study estimated bacterial numbers (total viable counts) and the incidence of Salmonella at three surface locations (ham, belly and neck) on 60 animals/carcasses processed through a small commercial pork abattoir (80 pigs d(-1)). Significant reductions (P HACCP in pork slaughter plants. This research will provide a sound scientific basis on which to develop and implement effective HACCP in pork abattoirs.

  19. Pressure Points: Preventing and Controlling Hypertension

    Science.gov (United States)

    ... Issue Past Issues Pressure Points: Preventing and Controlling Hypertension Past Issues / Summer 2006 Table of Contents For ... diagnosed with high blood pressure." Aditional Information On Hypertension MedlinePlus: High blood pressure: http://www.nlm.nih. ...

  20. Pointing control using a moving base of support.

    Science.gov (United States)

    Hondzinski, Jan M; Kwon, Taegyong

    2009-07-01

    The purposes of this study were to determine whether gaze direction provides a control signal for movement direction for a pointing task requiring a step and to gain insight into why discrepancies previously identified in the literature for endpoint accuracy with gaze directed eccentrically exist. Straight arm pointing movements were performed to real and remembered target locations, either toward or 30 degrees eccentric to gaze direction. Pointing occurred in normal room lighting or darkness while subjects sat, stood still or side-stepped left or right. Trunk rotation contributed 22-65% to gaze orientations when it was not constrained. Error differences for different target locations explained discrepancies among previous experiments. Variable pointing errors were influenced by gaze direction, while mean systematic pointing errors and trunk orientations were influenced by step direction. These data support the use of a control strategy that relies on gaze direction and equilibrium inputs for whole-body goal-directed movements.

  1. The timing of control signals underlying fast point-to-point arm movements.

    Science.gov (United States)

    Ghafouri, M; Feldman, A G

    2001-04-01

    It is known that proprioceptive feedback induces muscle activation when the facilitation of appropriate motoneurons exceeds their threshold. In the suprathreshold range, the muscle-reflex system produces torques depending on the position and velocity of the joint segment(s) that the muscle spans. The static component of the torque-position relationship is referred to as the invariant characteristic (IC). According to the equilibrium-point (EP) hypothesis, control systems produce movements by changing the activation thresholds and thus shifting the IC of the appropriate muscles in joint space. This control process upsets the balance between muscle and external torques at the initial limb configuration and, to regain the balance, the limb is forced to establish a new configuration or, if the movement is prevented, a new level of static torques. Taken together, the joint angles and the muscle torques generated at an equilibrium configuration define a single variable called the EP. Thus by shifting the IC, control systems reset the EP. Muscle activation and movement emerge following the EP resetting because of the natural physical tendency of the system to reach equilibrium. Empirical and simulation studies support the notion that the control IC shifts and the resulting EP shifts underlying fast point-to-point arm movements are gradual rather than step-like. However, controversies exist about the duration of these shifts. Some studies suggest that the IC shifts cease with the movement offset. Other studies propose that the IC shifts end early in comparison to the movement duration (approximately, at peak velocity). The purpose of this study was to evaluate the duration of the IC shifts underlying fast point-to-point arm movements. Subjects made fast (hand peak velocity about 1.3 m/s) planar arm movements toward different targets while grasping a handle. Hand forces applied to the handle and shoulder/elbow torques were, respectively, measured from a force sensor placed

  2. [A landscape ecological approach for urban non-point source pollution control].

    Science.gov (United States)

    Guo, Qinghai; Ma, Keming; Zhao, Jingzhu; Yang, Liu; Yin, Chengqing

    2005-05-01

    Urban non-point source pollution is a new problem appeared with the speeding development of urbanization. The particularity of urban land use and the increase of impervious surface area make urban non-point source pollution differ from agricultural non-point source pollution, and more difficult to control. Best Management Practices (BMPs) are the effective practices commonly applied in controlling urban non-point source pollution, mainly adopting local repairing practices to control the pollutants in surface runoff. Because of the close relationship between urban land use patterns and non-point source pollution, it would be rational to combine the landscape ecological planning with local BMPs to control the urban non-point source pollution, which needs, firstly, analyzing and evaluating the influence of landscape structure on water-bodies, pollution sources and pollutant removal processes to define the relationships between landscape spatial pattern and non-point source pollution and to decide the key polluted fields, and secondly, adjusting inherent landscape structures or/and joining new landscape factors to form new landscape pattern, and combining landscape planning and management through applying BMPs into planning to improve urban landscape heterogeneity and to control urban non-point source pollution.

  3. Microbial profile and critical control points during processing of 'robo ...

    African Journals Online (AJOL)

    Microbial profile and critical control points during processing of 'robo' snack from ... the relevant critical control points especially in relation to raw materials and ... to the quality of the various raw ingredients used were the roasting using earthen

  4. Word Length Selection Method for Controller Implementation on FPGAs Using the VHDL-2008 Fixed-Point and Floating-Point Packages

    Directory of Open Access Journals (Sweden)

    Urriza I

    2010-01-01

    Full Text Available Abstract This paper presents a word length selection method for the implementation of digital controllers in both fixed-point and floating-point hardware on FPGAs. This method uses the new types defined in the VHDL-2008 fixed-point and floating-point packages. These packages allow customizing the word length of fixed and floating point representations and shorten the design cycle simplifying the design of arithmetic operations. The method performs bit-true simulations in order to determine the word length to represent the constant coefficients and the internal signals of the digital controller while maintaining the control system specifications. A mixed-signal simulation tool is used to simulate the closed loop system as a whole in order to analyze the impact of the quantization effects and loop delays on the control system performance. The method is applied to implement a digital controller for a switching power converter. The digital circuit is implemented on an FPGA, and the simulations are experimentally verified.

  5. Controlling superconductivity by tunable quantum critical points.

    Science.gov (United States)

    Seo, S; Park, E; Bauer, E D; Ronning, F; Kim, J N; Shim, J-H; Thompson, J D; Park, Tuson

    2015-03-04

    The heavy fermion compound CeRhIn5 is a rare example where a quantum critical point, hidden by a dome of superconductivity, has been explicitly revealed and found to have a local nature. The lack of additional examples of local types of quantum critical points associated with superconductivity, however, has made it difficult to unravel the role of quantum fluctuations in forming Cooper pairs. Here, we show the precise control of superconductivity by tunable quantum critical points in CeRhIn5. Slight tin-substitution for indium in CeRhIn5 shifts its antiferromagnetic quantum critical point from 2.3 GPa to 1.3 GPa and induces a residual impurity scattering 300 times larger than that of pure CeRhIn5, which should be sufficient to preclude superconductivity. Nevertheless, superconductivity occurs at the quantum critical point of the tin-doped metal. These results underline that fluctuations from the antiferromagnetic quantum criticality promote unconventional superconductivity in CeRhIn5.

  6. Isosbestic points in the quality control oF spectrophotometers

    International Nuclear Information System (INIS)

    Oliveira, E.M. de.

    1987-01-01

    The methodology and results of quality control of spectrophotometers are reported and the calibrating of the monochromator by isosbestic points is presented. Four colorimetric indicators are used. The absorption curves (in acid and alkaline media) and mathematic determination of the common junction point are used for indicated the isosbetic points. (M.A.C.) [pt

  7. Triana Safehold: A New Gyroless, Sun-Pointing Attitude Controller

    Science.gov (United States)

    Chen, J.; Morgenstern, Wendy; Garrick, Joseph

    2001-01-01

    Triana is a single-string spacecraft to be placed in a halo orbit about the sun-earth Ll Lagrangian point. The Attitude Control Subsystem (ACS) hardware includes four reaction wheels, ten thrusters, six coarse sun sensors, a star tracker, and a three-axis Inertial Measuring Unit (IMU). The ACS Safehold design features a gyroless sun-pointing control scheme using only sun sensors and wheels. With this minimum hardware approach, Safehold increases mission reliability in the event of a gyroscope anomaly. In place of the gyroscope rate measurements, Triana Safehold uses wheel tachometers to help provide a scaled estimation of the spacecraft body rate about the sun vector. Since Triana nominally performs momentum management every three months, its accumulated system momentum can reach a significant fraction of the wheel capacity. It is therefore a requirement for Safehold to maintain a sun-pointing attitude even when the spacecraft system momentum is reasonably large. The tachometer sun-line rate estimation enables the controller to bring the spacecraft close to its desired sun-pointing attitude even with reasonably high system momentum and wheel drags. This paper presents the design rationale behind this gyroless controller, stability analysis, and some time-domain simulation results showing performances with various initial conditions. Finally, suggestions for future improvements are briefly discussed.

  8. Engineering to Control Noise, Loading, and Optimal Operating Points

    International Nuclear Information System (INIS)

    Mitchell R. Swartz

    2000-01-01

    Successful engineering of low-energy nuclear systems requires control of noise, loading, and optimum operating point (OOP) manifolds. The latter result from the biphasic system response of low-energy nuclear reaction (LENR)/cold fusion systems, and their ash production rate, to input electrical power. Knowledge of the optimal operating point manifold can improve the reproducibility and efficacy of these systems in several ways. Improved control of noise, loading, and peak production rates is available through the study, and use, of OOP manifolds. Engineering of systems toward the OOP-manifold drive-point peak may, with inclusion of geometric factors, permit more accurate uniform determinations of the calibrated activity of these materials/systems

  9. A Combined Control Chart for Identifying Out–Of–Control Points in Multivariate Processes

    Directory of Open Access Journals (Sweden)

    Marroquín–Prado E.

    2010-10-01

    Full Text Available The Hotelling's T2 control chart is widely used to identify out–of–control signals in multivariate processes. However, this chart is not sensitive to small shifts in the process mean vec tor. In this work we propose a control chart to identify out–of–control signals. The proposed chart is a combination of Hotelling's T2 chart, M chart proposed by Hayter et al. (1994 and a new chart based on Principal Components. The combination of these charts identifies any type and size of change in the process mean vector. Us ing simulation and the Average Run Length (ARL, the performance of the proposed control chart is evaluated. The ARL means the average points within control before an out–of–control point is detected, The results of the simulation show that the proposed chart is more sensitive that each one of the three charts individually

  10. 21 CFR 120.8 - Hazard Analysis and Critical Control Point (HACCP) plan.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Hazard Analysis and Critical Control Point (HACCP... SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION HAZARD ANALYSIS AND CRITICAL CONTROL POINT (HACCP) SYSTEMS General Provisions § 120.8 Hazard Analysis and Critical Control Point (HACCP) plan. (a) HACCP plan. Each...

  11. CRITICAL CONTROL POINTS ON THE TECHNOLOGICAL FLOW OF PANIFICATION

    Directory of Open Access Journals (Sweden)

    Gigel PARASCHIV

    2013-05-01

    Full Text Available Bread and panification products are intended for direct human consumption and underlying nutritional pyramid, it can affect the consumers health in case of biological, chemical or physical contamination, immediate or delayed, by noxious accumulation in the human organism. Only by rigorous compliance of the production rules throughout the technological process can ensure the quality and food safety of these products. If the risk can be prevented, eliminated or reduce to an acceptable level, as a result of a control actions made at that stage, it is considered a Critical Control Point (CCP. There can be checkpoints where it can exert a control action. Thus, the checkpoint is represented by any stage in which the risk factors, biological, chemical or physical, can be controlled in order to prevent, disrupt or reduce them to an acceptable level. This paper is referring to the control points on the technological flow of the bread fabrication, in all phases of this technological flow, laying stress on that points (or phases which can affect security and food safety, through the influence of parameters of any kind on the quality of finished products.

  12. The value of intermittent point-prevalence surveys of healthcare-associated infections for evaluating infection control interventions at Angkor Hospital for Children, Siem Reap, Cambodia.

    Science.gov (United States)

    Stoesser, N; Emary, K; Soklin, S; Peng An, K; Sophal, S; Chhomrath, S; Day, N P J; Limmathurotsakul, D; Nget, P; Pangnarith, Y; Sona, S; Kumar, V; Moore, C E; Chanpheaktra, N; Parry, C M

    2013-04-01

    There are limited data on the epidemiology of paediatric healthcare-associated infection (HCAI) and infection control in low-income countries. We describe the value of intermittent point-prevalence surveys for monitoring HCAI and evaluating infection control interventions in a Cambodian paediatric hospital. Hospital-wide, point-prevalence surveys were performed monthly in 2011. Infection control interventions introduced during this period included a hand hygiene programme and a ventilator-associated pneumonia (VAP) care bundle. Overall HCAI prevalence was 13.8/100 patients at-risk, with a significant decline over time. The highest HCAI rates (50%) were observed in critical care; the majority of HCAIs were respiratory (61%). Klebsiella pneumoniae was most commonly isolated and antimicrobial resistance was widespread. Hand hygiene compliance doubled to 51.6%, and total VAP cases/1000 patient-ventilator days fell from 30 to 10. Rates of HCAI were substantial in our institution, and antimicrobial resistance a major concern. Point-prevalence surveys are effective for HCAI surveillance, and in monitoring trends in response to infection control interventions.

  13. Fuzzy Controller Design Using FPGA for Photovoltaic Maximum Power Point Tracking

    OpenAIRE

    Basil M Hamed; Mohammed S. El-Moghany

    2012-01-01

    The cell has optimum operating point to be able to get maximum power. To obtain Maximum Power from photovoltaic array, photovoltaic power system usually requires Maximum Power Point Tracking (MPPT) controller. This paper provides a small power photovoltaic control system based on fuzzy control with FPGA technology design and implementation for MPPT. The system composed of photovoltaic module, buck converter and the fuzzy logic controller implemented on FPGA for controlling on/off time of MOSF...

  14. Stabilizing Planar Inverted Pendulum System Based on Fuzzy Nine-point Controller

    OpenAIRE

    Qi Qian; Liu Feng; Tang Yong-chuan; Yang Yang

    2013-01-01

    In order to stabilize planar inverted pendulum, after analyzing the physical characteristics of the planar inverted pendulum system, a pendulum nine-point controller and a car nine-point controller for X-axis and Y-axis were designed respectively. Then a fuzzy coordinator was designed using the fuzzy control theory based on the priority of those two controllers, and the priority level of the pendulum is higher than the car. Thus, the control tasks of each controller in each axis were harmoniz...

  15. Fuzzy Logic Based Set-Point Weighting Controller Tuning for an Internal Model Control Based PID Controller

    Directory of Open Access Journals (Sweden)

    Maruthai Suresh

    2009-10-01

    Full Text Available Controller tuning is the process of adjusting the parameters of the selected controller to achieve optimum response for the controlled process. For many of the control problems, a satisfactory performance is obtained by using PID controllers. One of the main problems with mathematical models of physical systems is that the parameters used in the models cannot be determined with absolute accuracy. The values of the parameters may change with time or various effects. In these cases, conventional controller tuning methods suffer when trying a lot to produce optimum response. In order to overcome these difficulties a fuzzy logic based Set- Point weighting controller tuning method is proposed. The effectiveness of the proposed scheme is analyzed through computer simulation using SIMULINK software and the results are presented. The fuzzy logic based simulation results are compared with Cohen-Coon (CC, Ziegler- Nichols (ZN, Ziegler – Nichols with Set- Point weighting (ZN-SPW, Internal Model Control (IMC and Internal model based PID controller responses (IMC-PID. The effects of process modeling errors and the importance of controller tuning have been brought out using the proposed control scheme.

  16. PointCom: semi-autonomous UGV control with intuitive interface

    Science.gov (United States)

    Rohde, Mitchell M.; Perlin, Victor E.; Iagnemma, Karl D.; Lupa, Robert M.; Rohde, Steven M.; Overholt, James; Fiorani, Graham

    2008-04-01

    Unmanned ground vehicles (UGVs) will play an important role in the nation's next-generation ground force. Advances in sensing, control, and computing have enabled a new generation of technologies that bridge the gap between manual UGV teleoperation and full autonomy. In this paper, we present current research on a unique command and control system for UGVs named PointCom (Point-and-Go Command). PointCom is a semi-autonomous command system for one or multiple UGVs. The system, when complete, will be easy to operate and will enable significant reduction in operator workload by utilizing an intuitive image-based control framework for UGV navigation and allowing a single operator to command multiple UGVs. The project leverages new image processing algorithms for monocular visual servoing and odometry to yield a unique, high-performance fused navigation system. Human Computer Interface (HCI) techniques from the entertainment software industry are being used to develop video-game style interfaces that require little training and build upon the navigation capabilities. By combining an advanced navigation system with an intuitive interface, a semi-autonomous control and navigation system is being created that is robust, user friendly, and less burdensome than many current generation systems. mand).

  17. Role of rural solid waste management in non-point source pollution control of Dianchi Lake catchments, China

    Institute of Scientific and Technical Information of China (English)

    Wenjing LU; Hongtao WANG

    2008-01-01

    In recent years, with control of the main municipal and industrial point pollution sources and implementation of cleaning for some inner pollution sources in the water body, the discharge of point source pollution decreased gradually, while non-point source pollution has become increasingly distressing in Dianchi Lake catchments. As one of the major targets in non-point source pollution control, an integrated solid waste controlling strategy combined with a technological solution and management system was proposed and implemented based on the waste disposal situation and characteristics of rural solid waste in the demonstration area. As the key technoogy in rural solid waste treatment, both centralized plantscale composting and a dispersed farmer-operated waste treating system showed promise in rendering timely benefits in efficiency, large handling capacity, high quality of the end product, as well as good economic return. Problems encountered during multi-substrates co-com-posting such as pathogens, high moisture content, asyn-chronism in the decomposition of different substrates, and low quality of the end product can all be tackled. 92.5% of solid waste was collected in the demonstration area, while the treating and recycling ratio reached 87.9%, which pre-vented 32.2 t nitrogen and 3.9 t phosphorus per year from entering the water body of Dianchi Lake after imple-mentation of the project.

  18. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Operation of internal transmitter control... Transmitter Control Internal Transmitter Control Systems § 90.473 Operation of internal transmitter control systems through licensed fixed control points. An internal transmitter control system may be operated...

  19. Hazard analysis and critical control point (HACCP) history and conceptual overview.

    Science.gov (United States)

    Hulebak, Karen L; Schlosser, Wayne

    2002-06-01

    The concept of Hazard Analysis and Critical Control Point (HACCP) is a system that enables the production of safe meat and poultry products through the thorough analysis of production processes, identification of all hazards that are likely to occur in the production establishment, the identification of critical points in the process at which these hazards may be introduced into product and therefore should be controlled, the establishment of critical limits for control at those points, the verification of these prescribed steps, and the methods by which the processing establishment and the regulatory authority can monitor how well process control through the HACCP plan is working. The history of the development of HACCP is reviewed, and examples of practical applications of HACCP are described.

  20. Critical Control Points in the Processing of Cassava Tuber for Ighu ...

    African Journals Online (AJOL)

    Determination of the critical control points in the processing of cassava tuber into Ighu was carried out. The critical control points were determined according to the Codex guidelines for the application of the HACCP system by conducting hazard analysis. Hazard analysis involved proper examination of each processing step ...

  1. Design and Implementation of Photovoltaic Maximum Power Point Tracking Controller

    Directory of Open Access Journals (Sweden)

    Fawaz S. Abdullah

    2018-03-01

    Full Text Available  The power supplied by any solar array depends upon the environmental conditions as weather conditions (temperature and radiation intensity and the incident angle of the radiant source. The work aims to study the maximum power tracking schemes that used to compare the system performance without and with different types of controllers. The maximum power points of the solar panel under test studied and compared with two controller's types.  The first controller is the proportional- integral - derivative controller type and the second is the perturbation and observation algorithm controller. The associated converter system is a microcontroller based type, whereas the results studied and compared of greatest power point of the Photovoltaic panels under the different two controllers. The experimental tests results compared with simulation results to verify accurate performance.

  2. Translational control is a major contributor to hypoxia induced gene expression

    International Nuclear Information System (INIS)

    Beucken, Twan van den; Magagnin, Michael G.; Jutten, Barry; Seigneuric, Renaud; Lambin, Philippe; Koritzinsky, Marianne; Wouters, Bradly G.

    2011-01-01

    Background and purpose: Hypoxia is a common feature of solid tumors that is associated with an aggressive phenotype, resistance to therapy and poor prognosis. Major contributors to these adverse effects are the transcriptional program activated by the HIF family of transcription factors as well as the translational response mediated by PERK-dependent phosphorylation of eIF2α and inhibition of mTORC1 activity. In this study we determined the relative contribution of both transcriptional and translational responses to changes in hypoxia induced gene expression. Material and methods: Total and efficiently translated (polysomal) mRNA was isolated from DU145 prostate carcinoma cells that were exposed for up to 24 h of hypoxia ( 2 ). Changes in transcription and translation were assessed using affymetrix microarray technology. Results: Our data reveal an unexpectedly large contribution of translation control on both induced and repressed gene expression at all hypoxic time points, particularly during acute hypoxia (2-4 h). Gene ontology analysis revealed that gene classes like transcription and signal transduction are stimulated by translational control whereas expression of genes involved in cell growth and protein metabolism are repressed during hypoxic conditions by translational control. Conclusions: Our data indicate that translation influences gene expression during hypoxia on a scale comparable to that of transcription.

  3. Wireless power charging using point of load controlled high frequency power converters

    Science.gov (United States)

    Miller, John M.; Campbell, Steven L.; Chambon, Paul H.; Seiber, Larry E.; White, Clifford P.

    2015-10-13

    An apparatus for wirelessly charging a battery of an electric vehicle is provided with a point of load control. The apparatus includes a base unit for generating a direct current (DC) voltage. The base unit is regulated by a power level controller. One or more point of load converters can be connected to the base unit by a conductor, with each point of load converter comprising a control signal generator that transmits a signal to the power level controller. The output power level of the DC voltage provided by the base unit is controlled by power level controller such that the power level is sufficient to power all active load converters when commanded to do so by any of the active controllers, without generating excessive power that may be otherwise wasted.

  4. Method of nuclear reactor control using a variable temperature load dependent set point

    International Nuclear Information System (INIS)

    Kelly, J.J.; Rambo, G.E.

    1982-01-01

    A method and apparatus for controlling a nuclear reactor in response to a variable average reactor coolant temperature set point is disclosed. The set point is dependent upon percent of full power load demand. A manually-actuated ''droop mode'' of control is provided whereby the reactor coolant temperature is allowed to drop below the set point temperature a predetermined amount wherein the control is switched from reactor control rods exclusively to feedwater flow

  5. Pasteurised milk and implementation of HACCP (Hazard Analysis Critical Control Point

    Directory of Open Access Journals (Sweden)

    T.B Murdiati

    2004-10-01

    Full Text Available The purpose of pasteurisation is to destroy pathogen bacteria without affecting the taste, flavor, and nutritional value. A study on the implementation of HACCP (Hazard Analysis Critical Control Point in producing pasteurized milk was carried out in four processing unit of pasteurised milk, one in Jakarta, two in Bandung and one in Bogor. The critical control points in the production line were identified. Milk samples were collected from the critical points and were analysed for the total number of microbes. Antibiotic residues were detected on raw milks. The study indicated that one unit in Bandung dan one unit in Jakarta produced pasteurized milk with lower number of microbes than the other units, due to better management and control applied along the chain of production. Penisilin residues was detected in raw milk used by unit in Bogor. Six critical points and the hazard might arise in those points were identified, as well as how to prevent the hazards. Quality assurance system such as HACCP would be able to produce high quality and safety of pasteurised milk, and should be implemented gradually.

  6. Pointing and control system performance and improvement strategies for the SOFIA Airborne Telescope

    Science.gov (United States)

    Graf, Friederike; Reinacher, Andreas; Jakob, Holger; Lampater, Ulrich; Pfueller, Enrico; Wiedemann, Manuel; Wolf, Jürgen; Fasoulas, Stefanos

    2016-07-01

    The Stratospheric Observatory for Infrared Astronomy (SOFIA) has already successfully conducted over 300 flights. In its early science phase, SOFIA's pointing requirements and especially the image jitter requirements of less than 1 arcsec rms have driven the design of the control system. Since the first observation flights, the image jitter has been gradually reduced by various control mechanisms. During smooth flight conditions, the current pointing and control system allows us to achieve the standards set for early science on SOFIA. However, the increasing demands on the image size require an image jitter of less than 0.4 arcsec rms during light turbulence to reach SOFIA's scientific goals. The major portion of the remaining image motion is caused by deformation and excitation of the telescope structure in a wide range of frequencies due to aircraft motion and aerodynamic and aeroacoustic effects. Therefore the so-called Flexible Body Compensation system (FBC) is used, a set of fixed-gain filters to counteract the structural bending and deformation. Thorough testing of the current system under various flight conditions has revealed a variety of opportunities for further improvements. The currently applied filters have solely been developed based on a FEM analysis. By implementing the inflight measurements in a simulation and optimization, an improved fixed-gain compensation method was identified. This paper will discuss promising results from various jitter measurements recorded with sampling frequencies of up to 400 Hz using the fast imaging tracking camera.

  7. A study on surveillance equipment at the exit/entry control point of nuclear facility

    International Nuclear Information System (INIS)

    Park, C. S.; Kim, D. Y.; Cha, H. L.; Kim, H. D.; Hong, J. S.

    1999-01-01

    Exit/Entry control is an essential measure at both entrances of the protected area and vital area of nuclear facility at which physical protection is required under the relevant laws and regulations. Especially, when there are heavy traffics of personnel and process equipment in those areas, automated surveillance devices have to be introduced to timely and efficiently screen out internal and external adversaries from achieving their goals of stealing of nuclear material and/or sabotage of the facility. The major portion of this study involves with integration and processing of signals from radiation detector, metal detector, and image monitor. This integrated device together with positive personal identification device which will be reinforced in near future would contribute to the establishment of total exit/entry control point of nuclear facility

  8. Microprocessor Controlled Maximum Power Point Tracker for Photovoltaic Application

    International Nuclear Information System (INIS)

    Jiya, J. D.; Tahirou, G.

    2002-01-01

    This paper presents a microprocessor controlled maximum power point tracker for photovoltaic module. Input current and voltage are measured and multiplied within the microprocessor, which contains an algorithm to seek the maximum power point. The duly cycle of the DC-DC converter, at which the maximum power occurs is obtained, noted and adjusted. The microprocessor constantly seeks for improvement of obtained power by varying the duty cycle

  9. Neutral-point current modeling and control for Neutral-Point Clamped three-level converter drive with small DC-link capacitors

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Munk-Nielsen, Stig; Busquets-Monge, Sergio

    2011-01-01

    A Neutral-Point-Clamped (NPC) three-level inverter with small DC-link capacitors is presented in this paper. This inverter requires zero average neutral-point current for stable neutral-point potential. A simple carrier based modulation strategy is proposed for achieving zero average neutral...... drive with only 14 μF DC-link capacitors. A fast and stable performance of the neutral-point voltage controller is achieved and verified by experiments....

  10. Identification of major sources controlling groundwater chemistry ...

    Indian Academy of Sciences (India)

    The study area Mettur forms an important industrial town situated NW of Salem district. The geology of the area is mainly composed of Archean crystalline metamorphic complexes. To iden- tify the major process activated for controlling the groundwater chemistry an attempt has been made by collecting a total of 46 ...

  11. Feedback control of Zero Moment Point for stable bipedal walking

    NARCIS (Netherlands)

    Looij, van de R.M.A.; Nijmeijer, H.; Kostic, D.

    2014-01-01

    In order to prevent the humanoid robot TUlip from falling a start has been made with a Zero Moment Point (ZMP) based controller. The chosen controller, which is called the Linear Inverted Pendulum Tracker (LIPT) controller, is based upon a lag between the real and reference ZMP and is used in

  12. Identifying and characterizing major emission point sources as a basis for geospatial distribution of mercury emissions inventories

    Science.gov (United States)

    Steenhuisen, Frits; Wilson, Simon J.

    2015-07-01

    Mercury is a global pollutant that poses threats to ecosystem and human health. Due to its global transport, mercury contamination is found in regions of the Earth that are remote from major emissions areas, including the Polar regions. Global anthropogenic emission inventories identify important sectors and industries responsible for emissions at a national level; however, to be useful for air transport modelling, more precise information on the locations of emission is required. This paper describes the methodology applied, and the results of work that was conducted to assign anthropogenic mercury emissions to point sources as part of geospatial mapping of the 2010 global anthropogenic mercury emissions inventory prepared by AMAP/UNEP. Major point-source emission sectors addressed in this work account for about 850 tonnes of the emissions included in the 2010 inventory. This work allocated more than 90% of these emissions to some 4600 identified point source locations, including significantly more point source locations in Africa, Asia, Australia and South America than had been identified during previous work to geospatially-distribute the 2005 global inventory. The results demonstrate the utility and the limitations of using existing, mainly public domain resources to accomplish this work. Assumptions necessary to make use of selected online resources are discussed, as are artefacts that can arise when these assumptions are applied to assign (national-sector) emissions estimates to point sources in various countries and regions. Notwithstanding the limitations of the available information, the value of this procedure over alternative methods commonly used to geo-spatially distribute emissions, such as use of 'proxy' datasets to represent emissions patterns, is illustrated. Improvements in information that would facilitate greater use of these methods in future work to assign emissions to point-sources are discussed. These include improvements to both national

  13. Vocational Preference Inventory High Point Codes Versus Expressed Choices as Predictors of College Major and Career Entry

    Science.gov (United States)

    Gade, Eldon M.; Soliah, David

    1975-01-01

    For 151 male graduates of the University of North Dakota, expressed choices measured by preferences made as high school seniors on the ACT Student Profile Section were significantly more accurate predictors of graduating college major and of career entry occupation than were their Vocational Preference Inventory high point codes. (Author)

  14. Air emission points for facilities in Iowa with operating permits for Title V of the Federal Clean Air Act_considered MAJOR permits

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Air emission points for facilities in Iowa with operating permits for Title V of the Federal Clean Air Act, considered "major" permits. Also includes emission points...

  15. Stationary point of the radiometric control of cesium contamination of agricultural animals

    International Nuclear Information System (INIS)

    1997-01-01

    Stationary point of the radiometric control of cesium contamination of an agricultural animals. Is intended for vital measurements of the contents of radiocesium in muscular tissue of a cattle. Can be used on cattle-breeding farms, providing points, in meat factories and personal facilities. As a base means for accommodation of the control point the motor-car is used. Design of the car allows to automate operations on deployment of the control point on a place and translation of one to a transport mode. Limits of measured specific activity of cesium contamination of a cattle is up 5*10 -9 to 5*10 -6 Ci/kg. The basic error on the bottom limit of measurement at confidence coefficient 0,95 is no more than 30%. Measurement time for the bottom limit of determined specific activity is no more than 30 s. There is automatic measurement mode. Type of a power is 220 V, 50 Hz. Range of working temperatures is up -15 to +35 centigrade. Relative humidity is no more than 98% at 25 centigrade. External gamma background is till 0.035 mR/h. Time of installation and dismantle of stationary control point is no more than 1,5 hours. The direct radiometric control in divo allows to fulfil and to use biotechnological process of removing of cesium isotopes from body of animals for decrease of levels of radioactive contamination

  16. Modeling of Maximum Power Point Tracking Controller for Solar Power System

    Directory of Open Access Journals (Sweden)

    Aryuanto Soetedjo

    2012-09-01

    Full Text Available In this paper, a Maximum Power Point Tracking (MPPT controller for solar power system is modeled using MATLAB Simulink. The model consists of PV module, buck converter, and MPPT controller. The contribution of the work is in the modeling of buck converter that allowing the input voltage of the converter, i.e. output voltage of PV is changed by varying the duty cycle, so that the maximum power point could be tracked when the environmental changes. The simulation results show that the developed model performs well in tracking the maximum power point (MPP of the PV module using Perturb and Observe (P&O Algorithm.

  17. Suicide risk in placebo-controlled studies of major depression

    NARCIS (Netherlands)

    Storosum, J. G.; van Zwieten, B. J.; van den Brink, W.; Gersons, B. P.; Broekmans, A. W.

    2001-01-01

    The purpose of this study was to determine if fear of an increased risk of attempted suicide in placebo groups participating in placebo-controlled studies is an argument against the performance of placebo-controlled trials in studies of major depression. All short-term and long-term,

  18. Hyporheic Interfaces Serve as Ecological Control Points for Mountainous Landscape Biological Productivity

    Science.gov (United States)

    Newcomer, M. E.; Dwivedi, D.; Raberg, J.; Fox, P. M.; Nico, P. S.; Wainwright, H. M.; Conrad, M. E.; Bill, M.; Bouskill, N.; Williams, K. H.; Hubbard, S.; Steefel, C. I.

    2017-12-01

    Riverine systems in snow-dominated mountainous regions often express complex biogeochemistry and river nutrient indicators as a function of hydrologic variability. In early spring, meltwater infiltration from a ripened snowpack creates a hydrological gradient through hillslopes, floodplains, and hyporheic zones. During this time, these systems are more-or-less a passive filter that allows the rising limb of the hydrograph to display chemo-dynamic relationships (inversely proportional) with solutes and nutrients. During the growing season, temperatures, plants, microbes, and hydrologic gradients shift dramatically and activate hyporheic-zone biogeochemistry as a major control on water nutrient degradation. Hyporheic biogeochemical reliance on the timing of meltwater infiltration and the possibility of a longer vernal window under future climate change indicates the importance of hyporheic cycling as the dominant ecological control point on carbon and nitrogen fluxes and transformations. The objective of our study is to develop a predictive understanding of the subsurface and surface controls on hyporheic biogeochemical behavior through data-model integration. Data from our 2017 field campaign in the East River, Colorado, a pristine, mountainous watershed, were taken at key times during the rising, peak, falling, and dry limb of the hydrograph. Throughout multiple locations across this spatial and temporal gradient, we measured surface and subsurface gases, geochemistry, isotopes, and hydrological flow conditions and used this data to constrain a numerical flow and reactive transport model of the hyporheic zone that included microbial and flow feedback dynamics. Our data coupled with the predictive power of our numerical model reveal that the hyporheic zone serves dual roles throughout the year—as a net source of nutrients and solutes during the early vernal phase, shifting to a net sink of nutrients during the summer dry season. The possibility of a future

  19. Analysis and research on Maximum Power Point Tracking of Photovoltaic Array with Fuzzy Logic Control and Three-point Weight Comparison Method

    Institute of Scientific and Technical Information of China (English)

    LIN; Kuang-Jang; LIN; Chii-Ruey

    2010-01-01

    The Photovoltaic Array has a best optimal operating point where the array operating can obtain the maximum power.However, the optimal operating point can be compromised by the strength of solar radiation,angle,and by the change of environment and load.Due to the constant changes in these conditions,it has become very difficult to locate the optimal operating point by following a mathematical model.Therefore,this study will focus mostly on the application of Fuzzy Logic Control theory and Three-point Weight Comparison Method in effort to locate the optimal operating point of solar panel and achieve maximum efficiency in power generation. The Three-point Weight Comparison Method is the comparison between the characteristic curves of the voltage of photovoltaic array and output power;it is a rather simple way to track the maximum power.The Fuzzy Logic Control,on the other hand,can be used to solve problems that cannot be effectively dealt with by calculation rules,such as concepts,contemplation, deductive reasoning,and identification.Therefore,this paper uses these two kinds of methods to make simulation successively. The simulation results show that,the Three-point Comparison Method is more effective under the environment with more frequent change of solar radiation;however,the Fuzzy Logic Control has better tacking efficiency under the environment with violent change of solar radiation.

  20. Control of exceptional points in photonic crystal slabs

    DEFF Research Database (Denmark)

    Kaminski, Piotr Marek; Taghizadeh, Alireza; Breinbjerg, Olav

    2017-01-01

    Various ways of controlling the extent of the ring of exceptional points in photonic crystal slabs are investigated. The extent of the ring in photonic crystal slabs is found to vary with the thickness of the slab. This enables recovery of Dirac cones in open, non-Hermitian systems, such as a pho...

  1. Hazard analysis and critical control point (HACCP) for an ultrasound food processing operation.

    Science.gov (United States)

    Chemat, Farid; Hoarau, Nicolas

    2004-05-01

    Emerging technologies, such as ultrasound (US), used for food and drink production often cause hazards for product safety. Classical quality control methods are inadequate to control these hazards. Hazard analysis of critical control points (HACCP) is the most secure and cost-effective method for controlling possible product contamination or cross-contamination, due to physical or chemical hazard during production. The following case study on the application of HACCP to an US food-processing operation demonstrates how the hazards at the critical control points of the process are effectively controlled through the implementation of HACCP.

  2. Guaranteeing Pointing Performance of the SDO Sun-Pointing Controllers in Light of Nonlinear Effects

    Science.gov (United States)

    Starin, Scott R.; Bourkland, Kristin L.

    2007-01-01

    The Solar Dynamics Observatory (SDO) mission is the first Space Weather Research Network mission, part of NASA s Living With a Star program.1 This program seeks to understand the changing Sun and its effects on the Solar System, life, and society. To this end, the SDO spacecraft will carry three Sun-observing instruments to geosynchronous orbit: Helioseismic and Magnetic Imager (HMI), led by Stanford University; Atmospheric Imaging Assembly (AIA), led by Lockheed Martin Space and Astrophysics Laboratory; and Extreme Ultraviolet Variability Experiment (EVE), led by the University of Colorado. Links describing the instruments in detail may be found through the SDO web site.2 The basic mission goals are to observe the Sun for a very high percentage of the 5-year mission (10-year goal) with long stretches of uninterrupted observations and with constant, high-data-rate transmission to a dedicated ground station. These goals guided the design of the spacecraft bus that will carry and service the three-instrument payload. At the time of this publication, the SDO spacecraft bus is well into the integration and testing phase at the NASA Goddard Space Flight Center (GSFC). A three-axis stabilized attitude control system (ACS) is needed both to point at the Sun accurately and to keep the roll about the Sun vector correctly positioned. The ACS has four reaction wheel modes and 2 thruster actuated modes. More details about the ACS in general and the control modes in particular can be found in Refs. [3-6]. All four of SDO s wheel-actuated control modes involve Sun-pointing controllers, as might be expected from such a mission. Science mode, during which most science data is collected, uses specialized guide telescopes to point accurately at the Sun. Inertial mode has two sub-modes, one tracks a Sun-referenced target orientation, and another maintains an absolute (star-referenced) target orientation, that both employ a Kalman filter to process data from a digital Sun sensor and

  3. Estimating continuous floodplain and major river bed topography mixing ordinal coutour lines and topographic points

    Science.gov (United States)

    Bailly, J. S.; Dartevelle, M.; Delenne, C.; Rousseau, A.

    2017-12-01

    Floodplain and major river bed topography govern many river biophysical processes during floods. Despite the grow of direct topographic measurements from LiDARS on riverine systems, it still room to develop methods for large (e.g. deltas) or very local (e.g. ponds) riverine systems that take advantage of information coming from simple SAR or optical image processing on floodplain, resulting from waterbodies delineation during flood up or down, and producing ordered coutour lines. The next challenge is thus to exploit such data in order to estimate continuous topography on the floodplain combining heterogeneous data: a topographic points dataset and a located but unknown and ordered contourline dataset. This article is comparing two methods designed to estimate continuous topography on the floodplain mixing ordinal coutour lines and continuous topographic points. For both methods a first estimation step is to value each contourline with elevation and a second step is next to estimate the continuous field from both topographic points and valued contourlines. The first proposed method is a stochastic method starting from multigaussian random-fields and conditional simualtion. The second is a deterministic method based on radial spline fonction for thin layers used for approximated bivariate surface construction. Results are first shown and discussed from a set of synoptic case studies presenting various topographic points density and topographic smoothness. Next, results are shown and discuss on an actual case study in the Montagua laguna, located in the north of Valparaiso, Chile.

  4. Nonpoint and Point Sources of Nitrogen in Major Watersheds of the United States

    Science.gov (United States)

    Puckett, Larry J.

    1994-01-01

    Estimates of nonpoint and point sources of nitrogen were made for 107 watersheds located in the U.S. Geological Survey's National Water-Quality Assessment Program study units throughout the conterminous United States. The proportions of nitrogen originating from fertilizer, manure, atmospheric deposition, sewage, and industrial sources were found to vary with climate, hydrologic conditions, land use, population, and physiography. Fertilizer sources of nitrogen are proportionally greater in agricultural areas of the West and the Midwest than in other parts of the Nation. Animal manure contributes large proportions of nitrogen in the South and parts of the Northeast. Atmospheric deposition of nitrogen is generally greatest in areas of greatest precipitation, such as the Northeast. Point sources (sewage and industrial) generally are predominant in watersheds near cities, where they may account for large proportions of the nitrogen in streams. The transport of nitrogen in streams increases as amounts of precipitation and runoff increase and is greatest in the Northeastern United States. Because no single nonpoint nitrogen source is dominant everywhere, approaches to control nitrogen must vary throughout the Nation. Watershed-based approaches to understanding nonpoint and point sources of contamination, as used by the National Water-Quality Assessment Program, will aid water-quality and environmental managers to devise methods to reduce nitrogen pollution.

  5. Wärtsilä turbocharger wash and dew point controller integration

    OpenAIRE

    Perälä, Antti

    2013-01-01

    There are two separate control cabinets used in Wärtsilä marine solutions, Turbocharger Wash Control and the Dew Point Control. The cabinets contain similar PLCs with I/O-cards needed in the system and touch screen for monitoring and controlling purposes. The purpose of the thesis was to find and implement a solution for integration of the control cabinets. The advantages of the integration are savings in material, space in the engine room and amount of work. The aim of the project was to cre...

  6. Acupuncture-Point Stimulation for Postoperative Pain Control: A Systematic Review and Meta-Analysis of Randomized Controlled Trials

    Directory of Open Access Journals (Sweden)

    Xian-Liang Liu

    2015-01-01

    Full Text Available The purpose of this study was to evaluate the effectiveness of Acupuncture-point stimulation (APS in postoperative pain control compared with sham/placebo acupuncture or standard treatments (usual care or no treatment. Only randomized controlled trials (RCTs were included. Meta-analysis results indicated that APS interventions improved VAS scores significantly and also reduced total morphine consumption. No serious APS-related adverse effects (AEs were reported. There is Level I evidence for the effectiveness of body points plaster therapy and Level II evidence for body points electroacupuncture (EA, body points acupressure, body points APS for abdominal surgery patients, auricular points seed embedding, manual auricular acupuncture, and auricular EA. We obtained Level III evidence for body points APS in patients who underwent cardiac surgery and cesarean section and for auricular-point stimulation in patients who underwent abdominal surgery. There is insufficient evidence to conclude that APS is an effective postoperative pain therapy in surgical patients, although the evidence does support the conclusion that APS can reduce analgesic requirements without AEs. The best level of evidence was not adequate in most subgroups. Some limitations of this study may have affected the results, possibly leading to an overestimation of APS effects.

  7. 47 CFR 90.471 - Points of operation in internal transmitter control systems.

    Science.gov (United States)

    2010-10-01

    ...) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control Systems § 90.471 Points of operation in internal transmitter control systems. The... licensee for internal communications and transmitter control purposes. Operating positions in internal...

  8. 21 CFR 123.6 - Hazard analysis and Hazard Analysis Critical Control Point (HACCP) plan.

    Science.gov (United States)

    2010-04-01

    ... Control Point (HACCP) plan. 123.6 Section 123.6 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Provisions § 123.6 Hazard analysis and Hazard Analysis Critical Control Point (HACCP) plan. (a) Hazard... fish or fishery product being processed in the absence of those controls. (b) The HACCP plan. Every...

  9. Risk factors for suicide completion in major depression: a case-control study of impulsive and aggressive behaviors in men.

    Science.gov (United States)

    Dumais, A; Lesage, A D; Alda, M; Rouleau, G; Dumont, M; Chawky, N; Roy, M; Mann, J J; Benkelfat, C; Turecki, Gustavo

    2005-11-01

    Major depression is a major risk factor for suicide. However, not all individuals with major depression commit suicide. Impulsive and aggressive behaviors have been proposed as risk factors for suicide, but it remains unclear whether their effect on the risk of suicide is at least partly explained by axis I disorders commonly associated with suicide, such as major depression. With a case-control design, a comparison of the level of impulsive and aggressive behaviors and the prevalence of associated psychopathology was carried out with control for the presence of primary psychopathology. One hundred and four male suicide completers who died during an episode of major depression and 74 living depressed male comparison subjects were investigated with proxy-based interviews by using structured diagnostic instruments and personality trait assessments. The authors found that current (6-month prevalence) alcohol abuse/dependence, current drug abuse/dependence, and cluster B personality disorders increased the risk of suicide in individuals with major depression. Also, higher levels of impulsivity and aggression were associated with suicide. An analysis by age showed that these risk factors were more specific to younger suicide victims (ages 18-40). A multivariate analysis indicated that current alcohol abuse/dependence and cluster B personality disorder were two independent predictors of suicide. Impulsive-aggressive personality disorders and alcohol abuse/dependence were two independent predictors of suicide in major depression, and impulsive and aggressive behaviors seem to underlie these risk factors. A developmental hypothesis of suicidal behavior, with impulsive and aggressive behaviors as the starting point, is discussed.

  10. Maximum Power Point Tracking Using Sliding Mode Control for Photovoltaic Array

    Directory of Open Access Journals (Sweden)

    J. Ghazanfari

    2013-09-01

    Full Text Available In this paper, a robust Maximum Power Point Tracking (MPPT for PV array has been proposed using sliding mode control by defining a new formulation for sliding surface which is based on increment conductance (INC method. The stability and robustness of the proposed controller are investigated to load variations and environment changes. Three different types of DC-DC converter are used in Maximum Power Point (MPP system and the results obtained are given. The simulation results confirm the effectiveness of the proposed method in the presence of load variations and environment changes for different types of DC-DC converter topologies.

  11. The point of no return: A fundamental limit on the ability to control thought and action.

    Science.gov (United States)

    Logan, Gordon D

    2015-01-01

    Bartlett (1958. Thinking. New York: Basic Books) described the point of no return as a point of irrevocable commitment to action, which was preceded by a period of gradually increasing commitment. As such, the point of no return reflects a fundamental limit on the ability to control thought and action. I review the literature on the point of no return, taking three perspectives. First, I consider the point of no return from the perspective of the controlled act, as a locus in the architecture and anatomy of the underlying processes. I review experiments from the stop-signal paradigm that suggest that the point of no return is located late in the response system. Then I consider the point of no return from the perspective of the act of control that tries to change the controlled act before it becomes irrevocable. From this perspective, the point of no return is a point in time that provides enough "lead time" for the act of control to take effect. I review experiments that measure the response time to the stop signal as the lead time required for response inhibition in the stop-signal paradigm. Finally, I consider the point of no return in hierarchically controlled tasks, in which there may be many points of no return at different levels of the hierarchy. I review experiments on skilled typing that suggest different points of no return for the commands that determine what is typed and the countermands that inhibit typing, with increasing commitment to action the lower the level in the hierarchy. I end by considering the point of no return in perception and thought as well as action.

  12. Remotely controlled repair at Douglas Point

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The Douglas Point nuclear generating station, completed in 1966, was Canada's first venture in commercial nuclear power. The discovery, 11 years later, of two perforations in auxiliary piping in a high radiation area led Atomic Energy of Canada Ltd and Ontario Hydro to develop new approaches to remotely controlled repair that will have much wider applications. Eddy current and ultrasonic testing were used to determine the pattern and extent of wear in a pipe encircled by a U-bolt, without first removing the U-bolt. Progress was monitored using remote TV cameras. Welding tools were designed and fabricated for the repairs, and a manipulator was also designed to transport the tool into its place of work. (author)

  13. Controlling organic chemical hazards in food manufacturing: a hazard analysis critical control points (HACCP) approach.

    Science.gov (United States)

    Ropkins, K; Beck, A J

    2002-08-01

    Hazard analysis by critical control points (HACCP) is a systematic approach to the identification, assessment and control of hazards. Effective HACCP requires the consideration of all hazards, i.e., chemical, microbiological and physical. However, to-date most 'in-place' HACCP procedures have tended to focus on the control of microbiological and physical food hazards. In general, the chemical component of HACCP procedures is either ignored or limited to applied chemicals, e.g., food additives and pesticides. In this paper we discuss the application of HACCP to a broader range of chemical hazards, using organic chemical contaminants as examples, and the problems that are likely to arise in the food manufacturing sector. Chemical HACCP procedures are likely to result in many of the advantages previously identified for microbiological HACCP procedures: more effective, efficient and economical than conventional end-point-testing methods. However, the high costs of analytical monitoring of chemical contaminants and a limited understanding of formulation and process optimisation as means of controlling chemical contamination of foods are likely to prevent chemical HACCP becoming as effective as microbiological HACCP.

  14. Neuromuscular control of the point to point and oscillatory movements of a sagittal arm with the actor-critic reinforcement learning method.

    Science.gov (United States)

    Golkhou, Vahid; Parnianpour, Mohamad; Lucas, Caro

    2005-04-01

    In this study, we have used a single link system with a pair of muscles that are excited with alpha and gamma signals to achieve both point to point and oscillatory movements with variable amplitude and frequency.The system is highly nonlinear in all its physical and physiological attributes. The major physiological characteristics of this system are simultaneous activation of a pair of nonlinear muscle-like-actuators for control purposes, existence of nonlinear spindle-like sensors and Golgi tendon organ-like sensor, actions of gravity and external loading. Transmission delays are included in the afferent and efferent neural paths to account for a more accurate representation of the reflex loops.A reinforcement learning method with an actor-critic (AC) architecture instead of middle and low level of central nervous system (CNS), is used to track a desired trajectory. The actor in this structure is a two layer feedforward neural network and the critic is a model of the cerebellum. The critic is trained by state-action-reward-state-action (SARSA) method. The critic will train the actor by supervisory learning based on the prior experiences. Simulation studies of oscillatory movements based on the proposed algorithm demonstrate excellent tracking capability and after 280 epochs the RMS error for position and velocity profiles were 0.02, 0.04 rad and rad/s, respectively.

  15. Maximum-power-point tracking control of solar heating system

    KAUST Repository

    Huang, Bin-Juine

    2012-11-01

    The present study developed a maximum-power point tracking control (MPPT) technology for solar heating system to minimize the pumping power consumption at an optimal heat collection. The net solar energy gain Q net (=Q s-W p/η e) was experimentally found to be the cost function for MPPT with maximum point. The feedback tracking control system was developed to track the optimal Q net (denoted Q max). A tracking filter which was derived from the thermal analytical model of the solar heating system was used to determine the instantaneous tracking target Q max(t). The system transfer-function model of solar heating system was also derived experimentally using a step response test and used in the design of tracking feedback control system. The PI controller was designed for a tracking target Q max(t) with a quadratic time function. The MPPT control system was implemented using a microprocessor-based controller and the test results show good tracking performance with small tracking errors. It is seen that the average mass flow rate for the specific test periods in five different days is between 18.1 and 22.9kg/min with average pumping power between 77 and 140W, which is greatly reduced as compared to the standard flow rate at 31kg/min and pumping power 450W which is based on the flow rate 0.02kg/sm 2 defined in the ANSI/ASHRAE 93-1986 Standard and the total collector area 25.9m 2. The average net solar heat collected Q net is between 8.62 and 14.1kW depending on weather condition. The MPPT control of solar heating system has been verified to be able to minimize the pumping energy consumption with optimal solar heat collection. © 2012 Elsevier Ltd.

  16. A Biomechanical Model of Single-joint Arm Movement Control Based on the Equilibrium Point Hypothesis

    OpenAIRE

    Masataka, SUZUKI; Yoshihiko, YAMAZAKI; Yumiko, TANIGUCHI; Department of Psychology, Kinjo Gakuin University; Department of Health and Physical Education, Nagoya Institute of Technology; College of Human Life and Environment, Kinjo Gakuin University

    2003-01-01

    SUZUKI,M., YAMAZAKI,Y. and TANIGUCHI,Y., A Biomechanical Model of Single-joint Arm Movement Control Based on the Equilibrium Point Hypothesis. Adv. Exerc. Sports Physiol., Vol.9, No.1 pp.7-25, 2003. According to the equilibrium point hypothesis of motor control, control action of muscles is not explicitly computed, but rather arises as a consequence of interaction among moving equilibrium point, reflex feedback and muscle mechanical properties. This approach is attractive as it obviates the n...

  17. Maintenance of equilibrium point control during an unexpectedly loaded rapid limb movement.

    Science.gov (United States)

    Simmons, R W; Richardson, C

    1984-06-08

    Two experiments investigated whether the equilibrium point hypothesis or the mass-spring model of motor control subserves positioning accuracy during spring loaded, rapid, bi-articulated movement. For intact preparations, the equilibrium point hypothesis predicts response accuracy to be determined by a mixture of afferent and efferent information, whereas the mass-spring model predicts positioning to be under a direct control system. Subjects completed a series of load-resisted training trials to a spatial target. The magnitude of a sustained spring load was unexpectedly increased on selected trials. Results indicated positioning accuracy and applied force varied with increases in load, which suggests that the original efferent commands are modified by afferent information during the movement as predicted by the equilibrium point hypothesis.

  18. Application of point system in the project control of Ling'ao Nuclear Power Station

    International Nuclear Information System (INIS)

    Xie ahai

    2005-01-01

    Schedule control and cost control are very complicated issues even we set up the detail schedules and engineering measurements requirements for erection of a nuclear power project. In order to solve these problems, a Point System is used in Ling Ao (LA) Nuclear Power Project. This paper introduces the method. The Point System is a measurement system of workload. The measurement unit of any erection works is a Point only. A Point of workload is defined as the equivalent measurement quantities, which could be completed by a relevant skill worker within an hour. A set of procedure manuals for different installations has been set up. The calculation models of equipment installation, piping, cabling are addressed for example in the paper. The application of the Point System in the schedule control is shown in the paper. The following issues are highlighted: to define the duration of a piping activity in the Project Level 2 Schedule, to draught the curves of Point Schedules for different erection fields, to analyze the productive efficiency, to define erection quota of each month for different erection teams, to follow up the erection progress on site. The application of the Point System in the payment of erection contract is outlined. The calculation formula of a monthly payment is given. The advantage of the payment calculation method is discussed, for example, more accurate, very easy and clearly to check the measurement quantities completed on site, to control lump-sum cost. (authors)

  19. Use of four major tobacco control interventions in New Zealand: a review.

    Science.gov (United States)

    Wilson, Nick; Thomson, George; Edwards, Richard

    2008-06-20

    To identify the extent to which four major population-level tobacco control interventions were used in New Zealand from January 2000 to June 2007. We selected the four population-based tobacco control interventions with the strongest evidence base. For each intervention, we undertook literature searches to identify the extent of their use in New Zealand during the study period and made comparisons with the other 29 OECD countries. Increasing the unit price of tobacco: New Zealand has high tobacco prices, but the policy on tax has several limitations relative to best practice within OECD countries. In particular, the high price appears to be shifting many smokers from factory-made cigarettes to loose tobacco, rather than stimulating quitting. Controls on marketing: While New Zealand compares favourably with most other OECD countries for tobacco marketing controls, some jurisdictions have made more progress in specific areas (e.g. eliminating point-of-sale product displays and removing misleading descriptors on packaging). Mass media campaigns: The country routinely invests in these campaigns, but the budget is only around $1.20 per capita per year. Some design aspects of the campaigns are progressive, but comparisons with other countries indicate potential for improvements (e.g. learning from counter-industry campaigns in the USA). Smokefree environments regulations: New Zealand was one of the first OECD countries to implement comprehensive smokefree workplaces legislation (including restaurants and bars) and it still compares well. But gaps remain when compared to some other OECD jurisdictions (e.g. no smokefree car laws). There is still substantial scope for New Zealand to catch up to OECD leaders in these key tobacco control areas. In particular, there needs to be higher tax levels for loose tobacco (relative to factory-made cigarettes) and the elimination of residual marketing. There are also important gaps in exploiting synergies between interventions in this

  20. An optimising controller for Hinkley Point B AGR boilers

    International Nuclear Information System (INIS)

    Wells, C.

    1986-01-01

    The improvements to the control system at Hinkley Point 'B' Power Station has as one of its objectives the provision of a half unit valve controller. This will enable the asymmetry between the boiler half units, which is a feature of current operation, to be reduced. The use of an on-line boiler model in conjunction with this facility will allow the risk to the boilers from corrosion, creep, and vibration to be assessed and held at the minimum attainable value, thereby prolonging plant life whilst maximising output and efficiency. (author)

  1. Remotely controlled repairs at Douglas Point NGS

    International Nuclear Information System (INIS)

    Broad, Les

    In September, 1977, leakage of heavy water at a rate of 125 kg/hr was detected in an area of the Douglas Point NGS reactor vault below the calandria known as the lower labyrinth. Radiation in the area ranges up to 5000 R/hr and the only ready access was through four 75 mm inspection ports that open into the moderator room. Remote-controlled equipment was designed and built to diagnose the problems and carry out repairs. All damaged piping was fixed, supports were replaced as needed, and system vibration was reduced. The work was done with no injuries and little radiation dose

  2. Model Predictive Control of Z-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    2011-01-01

    This paper presents Model Predictive Control (MPC) of Z-source Neutral Point Clamped (NPC) inverter. For illustration, current control of Z-source NPC grid-connected inverter is analyzed and simulated. With MPC’s advantage of easily including system constraints, load current, impedance network...... response are obtained at the same time with a formulated Z-source NPC inverter network model. Operation steady state and transient state simulation results of MPC are going to be presented, which shows good reference tracking ability of this method. It provides new control method for Z-source NPC inverter...

  3. Ants: Major Functional Elements in Fruit Agro-Ecosystems and Biological Control Agents

    Directory of Open Access Journals (Sweden)

    Lamine Diamé

    2017-12-01

    Full Text Available Ants are a very diverse taxonomic group. They display remarkable social organization that has enabled them to be ubiquitous throughout the world. They make up approximately 10% of the world’s animal biomass. Ants provide ecosystem services in agrosystems by playing a major role in plant pollination, soil bioturbation, bioindication, and the regulation of crop-damaging insects. Over recent decades, there have been numerous studies in ant ecology and the focus on tree cropping systems has given added importance to ant ecology knowledge. The only missing point in this knowledge is the reasons underlying difference between the positive and negative effects of ants in tree cropping systems. This review article provides an overview of knowledge of the roles played by ants in orchards as functional elements, and on the potential of Oecophylla weaver ants as biological control agents. It also shows the potential and relevance of using ants as an agro-ecological diagnosis tool in orchards. Lastly, it demonstrates the potential elements which may determine the divergent negative and positive of their effects on cropping systems.

  4. Control of tongue movements in speech: The Equilibrium point Hypothesis perspective

    OpenAIRE

    Perrier , Pascal; Loevenbruck , Hélène; Payan , Yohan

    1996-01-01

    In this paper , the application of the Equilibrium Point Hypothesis— originally proposed by Feldman for the control of limb movements— to speech control is analysed . In the first part , physiological data published in the literature which argue in favour of such control for the tongue are presented and the possible role of this motor process in a global control model of the tongue is explicated . In the second part , using the example of the acoustic variability associated with vowel reducti...

  5. Remotely controlled repair of piping at Douglas Point

    International Nuclear Information System (INIS)

    Conrath, J.J.

    1983-06-01

    The 200 MWe Douglas Point Nuclear Generating Station which started operation in 1966 was Canada's first commercial nuclear power plant. In 1977, after 11 years of operation, leakage of heavy water was detected and traced to the Moderator Piping System (pipe sizes 19 mm to 76 mm) located in a vault below the reactor where the radiation fields during shutdown ranged up to 5000 R/Hr. Inspection using remotely operated TV cameras showed that a 'U' bolt clamp support had worn through the wall of one pipe and resulted in the leakage and also that wear was occurring on other pipes. An extensive repair plan was subsequently undertaken in the form of a joint venture of the designer-owner Atomic Energy of Canada Limited, and the builder-operator, Ontario Hydro. This paper describes the equipment and procedures used in remotely controlled repairs at Douglas Point

  6. Testing of an End-Point Control Unit Designed to Enable Precision Control of Manipulator-Coupled Spacecraft

    Science.gov (United States)

    Montgomery, Raymond C.; Ghosh, Dave; Tobbe, Patrick A.; Weathers, John M.; Manouchehri, Davoud; Lindsay, Thomas S.

    1994-01-01

    This paper presents an end-point control concept designed to enable precision telerobotic control of manipulator-coupled spacecraft. The concept employs a hardware unit (end-point control unit EPCU) that is positioned between the end-effector of the Space Shuttle Remote Manipulator System and the payload. Features of the unit are active compliance (control of the displacement between the end-effector and the payload), to allow precision control of payload motions, and inertial load relief, to prevent the transmission of loads between the end-effector and the payload. This paper presents the concept and studies the active compliance feature using a simulation and hardware. Results of the simulation show the effectiveness of the EPCU in smoothing the motion of the payload. Results are presented from initial, limited tests of a laboratory hardware unit on a robotic arm testbed at the l Space Flight Center. Tracking performance of the arm in a constant speed automated retraction and extension maneuver of a heavy payload with and without the unit active is compared for the design speed and higher speeds. Simultaneous load reduction and tracking performance are demonstrated using the EPCU.

  7. Big rock point restoration project BWR major component removal, packaging and shipping - planning and experience

    International Nuclear Information System (INIS)

    Milner, T.; Dam, S.; Papp, M.; Slade, J.; Slimp, B.; Nurden, P.

    2001-01-01

    The Big Rock Point boiling water reactor (BWR) at Charlevoix, MI was permanently shut down on August 29th 1997. In 1999 BNFL Inc.'s Reactor Decommissioning Group (RDG) was awarded a contract by Consumers Energy (CECo) for the Big Rock Point (BRP) Major Component Removal (MCR) project. BNFL Inc. RDG has teamed with MOTA, Sargent and Lundy and MDM Services to plan and execute MCR in support of the facility restoration project. The facility restoration project will be completed by 2005. Key to the success of the project has been the integration of best available demonstrated technology into a robust and responsive project management approach, which places emphasis on safety and quality assurance in achieving project milestones linked to time and cost. To support decommissioning of the BRP MCR activities, a reactor vessel (RV) shipping container is required. Discussed in this paper is the design and fabrication of a 10 CFR Part 71 Type B container necessary to ship the BRP RV. The container to be used for transportation of the RV to the burial site was designed as an Exclusive Use Type B package for shipment and burial at the Barnwell, South Carolina (SC) disposal facility. (author)

  8. Analysis on Single Point Vulnerabilities of Plant Control System

    International Nuclear Information System (INIS)

    Chi, Moon Goo; Lee, Eun Chan; Bae, Yeon Kyoung

    2011-01-01

    The Plant Control System (PCS) is a system that controls pumps, valves, dampers, etc. in nuclear power plants with an OPR-1000 design. When there is a failure or spurious actuation of the critical components in the PCS, it can result in unexpected plant trips or transients. From this viewpoint, single point vulnerabilities are evaluated in detail using failure mode effect analyses (FMEA) and fault tree analyses (FTA). This evaluation demonstrates that the PCS has many vulnerable components and the analysis results are provided for OPR-1000 plants for reliability improvements that can reduce their vulnerabilities

  9. Analysis on Single Point Vulnerabilities of Plant Control System

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Moon Goo; Lee, Eun Chan; Bae, Yeon Kyoung [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2011-08-15

    The Plant Control System (PCS) is a system that controls pumps, valves, dampers, etc. in nuclear power plants with an OPR-1000 design. When there is a failure or spurious actuation of the critical components in the PCS, it can result in unexpected plant trips or transients. From this viewpoint, single point vulnerabilities are evaluated in detail using failure mode effect analyses (FMEA) and fault tree analyses (FTA). This evaluation demonstrates that the PCS has many vulnerable components and the analysis results are provided for OPR-1000 plants for reliability improvements that can reduce their vulnerabilities.

  10. Reducing symptoms of major depressive disorder through a systematic training of general emotion regulation skills: protocol of a randomized controlled trial.

    Science.gov (United States)

    Ehret, Anna M; Kowalsky, Judith; Rief, Winfried; Hiller, Wolfgang; Berking, Matthias

    2014-01-27

    Major Depressive Disorder is one of the most challenging mental health problems of our time. Although effective psychotherapeutic treatments are available, many patients fail to demonstrate clinically significant improvements. Difficulties in emotion regulation have been identified as putative risk and maintaining factors for Major Depressive Disorder. Systematically enhancing adaptive emotion regulation skills should thus help reduce depressive symptom severity. However, at this point, no study has systematically evaluated effects of increasing adaptive emotion regulation skills application on symptoms of Major Depressive Disorder. In the intended study, we aim to evaluate stand-alone effects of a group-based training explicitly and exclusively targeting general emotion regulation skills on depressive symptom severity and assess whether this training augments the outcome of subsequent individual cognitive behavioral therapy for depression. In the evaluation of the Affect Regulation Training, we will conduct a prospective randomized-controlled trial. Effects of the Affect Regulation Training on depressive symptom severity and outcomes of subsequent individual therapy for depression will be compared with an active, common factor based treatment and a waitlist control condition. The study sample will include 120 outpatients meeting criteria for Major Depressive Disorder. Depressive symptom severity as assessed by the Hamilton Rating Scale will serve as our primary study outcome. Secondary outcomes will include further indicators of mental health and changes in adaptive emotion regulation skills application. All outcomes will be assessed at intake and at 10 points in time over the course of the 15-month study period. Measures will include self-reports, observer ratings, momentary ecological assessments, and will be complemented in subsamples by experimental investigations and the analysis of hair steroids. If findings should support the hypothesis that enhancing

  11. Multi-Class Simultaneous Adaptive Segmentation and Quality Control of Point Cloud Data

    Directory of Open Access Journals (Sweden)

    Ayman Habib

    2016-01-01

    Full Text Available 3D modeling of a given site is an important activity for a wide range of applications including urban planning, as-built mapping of industrial sites, heritage documentation, military simulation, and outdoor/indoor analysis of airflow. Point clouds, which could be either derived from passive or active imaging systems, are an important source for 3D modeling. Such point clouds need to undergo a sequence of data processing steps to derive the necessary information for the 3D modeling process. Segmentation is usually the first step in the data processing chain. This paper presents a region-growing multi-class simultaneous segmentation procedure, where planar, pole-like, and rough regions are identified while considering the internal characteristics (i.e., local point density/spacing and noise level of the point cloud in question. The segmentation starts with point cloud organization into a kd-tree data structure and characterization process to estimate the local point density/spacing. Then, proceeding from randomly-distributed seed points, a set of seed regions is derived through distance-based region growing, which is followed by modeling of such seed regions into planar and pole-like features. Starting from optimally-selected seed regions, planar and pole-like features are then segmented. The paper also introduces a list of hypothesized artifacts/problems that might take place during the region-growing process. Finally, a quality control process is devised to detect, quantify, and mitigate instances of partially/fully misclassified planar and pole-like features. Experimental results from airborne and terrestrial laser scanning as well as image-based point clouds are presented to illustrate the performance of the proposed segmentation and quality control framework.

  12. Implementation of Maximum Power Point Tracking (MPPT) Solar Charge Controller using Arduino

    Science.gov (United States)

    Abdelilah, B.; Mouna, A.; KouiderM’Sirdi, N.; El Hossain, A.

    2018-05-01

    the platform Arduino with a number of sensors standard can be used as components of an electronic system for acquiring measures and controls. This paper presents the design of a low-cost and effective solar charge controller. This system includes several elements such as the solar panel converter DC/DC, battery, circuit MPPT using Microcontroller, sensors, and the MPPT algorithm. The MPPT (Maximum Power Point Tracker) algorithm has been implemented using an Arduino Nano with the preferred program. The voltage and current of the Panel are taken where the program implemented will work and using this algorithm that MPP will be reached. This paper provides details on the solar charge control device at the maximum power point. The results include the change of the duty cycle with the change in load and thus mean the variation of the buck converter output voltage and current controlled by the MPPT algorithm.

  13. Maximum power point tracking controller for PV systems using neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Bahgat, A.B.G. [Cairo Univ. (Egypt). Faculty of Engineering; Helwa, N.H.; Ahmad, G.E.; El Shenawy, E.T. [National Research Center, Dokki, Cairo (Egypt). Solar Energy Dept.

    2005-07-01

    This paper presents a development and implementation of a PC-based maximum power point tracker (MPPT) for PV system using neural networks (NN). The system consists of a PV module via a MPPT supplying a dc motor that drives an air fan. The control algorithm is developed to use the artificial NN for detecting the optimal operating point under different operating conditions, then the control action gives the driving signals to the MPPT. A PC is used for data acquisition, running the control algorithm, data storage, as well as data display and analysis. The system has been implemented and tested under various operating conditions. The experimental results showed that the PV system with MPPT always tracks the peak power point of the PV module under various operating conditions. The MPPT transmits about 97% of the actual maximum power generated by the PV module. The MPPT not only increases the power from the PV module to the load, but also maintains longer operating periods for the PV system. The air velocity and the air mass flow rate of the mechanical load are increased considerably, due to the increase of the PV system power. It is also found that the increase in the output energy due to using the MPPT is about 45.2% for a clear sunny day. (Author)

  14. Optimization of Control Points Number at Coordinate Measurements based on the Monte-Carlo Method

    Science.gov (United States)

    Korolev, A. A.; Kochetkov, A. V.; Zakharov, O. V.

    2018-01-01

    Improving the quality of products causes an increase in the requirements for the accuracy of the dimensions and shape of the surfaces of the workpieces. This, in turn, raises the requirements for accuracy and productivity of measuring of the workpieces. The use of coordinate measuring machines is currently the most effective measuring tool for solving similar problems. The article proposes a method for optimizing the number of control points using Monte Carlo simulation. Based on the measurement of a small sample from batches of workpieces, statistical modeling is performed, which allows one to obtain interval estimates of the measurement error. This approach is demonstrated by examples of applications for flatness, cylindricity and sphericity. Four options of uniform and uneven arrangement of control points are considered and their comparison is given. It is revealed that when the number of control points decreases, the arithmetic mean decreases, the standard deviation of the measurement error increases and the probability of the measurement α-error increases. In general, it has been established that it is possible to repeatedly reduce the number of control points while maintaining the required measurement accuracy.

  15. Maximum Power Point Tracking Control of Photovoltaic Systems: A Polynomial Fuzzy Model-Based Approach

    DEFF Research Database (Denmark)

    Rakhshan, Mohsen; Vafamand, Navid; Khooban, Mohammad Hassan

    2018-01-01

    This paper introduces a polynomial fuzzy model (PFM)-based maximum power point tracking (MPPT) control approach to increase the performance and efficiency of the solar photovoltaic (PV) electricity generation. The proposed method relies on a polynomial fuzzy modeling, a polynomial parallel......, a direct maximum power (DMP)-based control structure is considered for MPPT. Using the PFM representation, the DMP-based control structure is formulated in terms of SOS conditions. Unlike the conventional approaches, the proposed approach does not require exploring the maximum power operational point...

  16. Microbial profile and critical control points during processing of 'robo ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-05-18

    May 18, 2009 ... frying, surface fat draining, open-air cooling, and holding/packaging in polyethylene films during sales and distribution. The product was, however, classified under category III with respect to risk and the significance of monitoring and evaluation of quality using the hazard analysis critical control point.

  17. Geodetic Control Points, Benchmarks; Vertical elevation bench marks for monumented geodetic survey control points for which mean sea level elevations have been determined., Published in 1995, 1:24000 (1in=2000ft) scale, Rhode Island and Providence Plantations.

    Data.gov (United States)

    NSGIC State | GIS Inventory — Geodetic Control Points dataset current as of 1995. Benchmarks; Vertical elevation bench marks for monumented geodetic survey control points for which mean sea level...

  18. Comparison of Extremum-Seeking Control Techniques for Maximum Power Point Tracking in Photovoltaic Systems

    Directory of Open Access Journals (Sweden)

    Chen-Han Wu

    2011-12-01

    Full Text Available Due to Japan’s recent nuclear crisis and petroleum price hikes, the search for renewable energy sources has become an issue of immediate concern. A promising candidate attracting much global attention is solar energy, as it is green and also inexhaustible. A maximum power point tracking (MPPT controller is employed in such a way that the output power provided by a photovoltaic (PV system is boosted to its maximum level. However, in the context of abrupt changes in irradiance, conventional MPPT controller approaches suffer from insufficient robustness against ambient variation, inferior transient response and a loss of output power as a consequence of the long duration required of tracking procedures. Accordingly, in this work the maximum power point tracking is carried out successfully using a sliding mode extremum-seeking control (SMESC method, and the tracking performances of three controllers are compared by simulations, that is, an extremum-seeking controller, a sinusoidal extremum-seeking controller and a sliding mode extremum-seeking controller. Being able to track the maximum power point promptly in the case of an abrupt change in irradiance, the SMESC approach is proven by simulations to be superior in terms of system dynamic and steady state responses, and an excellent robustness along with system stability is demonstrated as well.

  19. A New MPPT Control for Photovoltaic Panels by Instantaneous Maximum Power Point Tracking

    Science.gov (United States)

    Tokushima, Daiki; Uchida, Masato; Kanbei, Satoshi; Ishikawa, Hiroki; Naitoh, Haruo

    This paper presents a new maximum power point tracking control for photovoltaic (PV) panels. The control can be categorized into the Perturb and Observe (P & O) method. It utilizes instantaneous voltage ripples at PV panel output terminals caused by the switching of a chopper connected to the panel in order to identify the direction for the maximum power point (MPP). The tracking for the MPP is achieved by a feedback control of the average terminal voltage of the panel. Appropriate use of the instantaneous and the average values of the PV voltage for the separate purposes enables both the quick transient response and the good convergence with almost no ripples simultaneously. The tracking capability is verified experimentally with a 2.8 W PV panel under a controlled experimental setup. A numerical comparison with a conventional P & O confirms that the proposed control extracts much more power from the PV panel.

  20. Mathematic-Graphical Formalization of Switch Point Control Circuit Function

    Directory of Open Access Journals (Sweden)

    Juraj Zdansky

    2004-01-01

    Full Text Available This article describes authors designed method then enables mathematic – graphical formalization of system’s functional specification. The result of this method is algebraic system – finite automata that is written in transition table. This transition table is possible to overwrite to graphic form (state diagram or to mathematic form (transition and output function. This method is described by example of switch point control circuit.

  1. Polar coordinated fuzzy controller based real-time maximum-power point control of photovoltaic system

    Energy Technology Data Exchange (ETDEWEB)

    Syafaruddin; Hiyama, Takashi [Department of Computer Science and Electrical Engineering of Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555 (Japan); Karatepe, Engin [Department of Electrical and Electronics Engineering of Ege University, 35100 Bornova-Izmir (Turkey)

    2009-12-15

    It is crucial to improve the photovoltaic (PV) system efficiency and to develop the reliability of PV generation control systems. There are two ways to increase the efficiency of PV power generation system. The first is to develop materials offering high conversion efficiency at low cost. The second is to operate PV systems optimally. However, the PV system can be optimally operated only at a specific output voltage and its output power fluctuates under intermittent weather conditions. Moreover, it is very difficult to test the performance of a maximum-power point tracking (MPPT) controller under the same weather condition during the development process and also the field testing is costly and time consuming. This paper presents a novel real-time simulation technique of PV generation system by using dSPACE real-time interface system. The proposed system includes Artificial Neural Network (ANN) and fuzzy logic controller scheme using polar information. This type of fuzzy logic rules is implemented for the first time to operate the PV module at optimum operating point. ANN is utilized to determine the optimum operating voltage for monocrystalline silicon, thin-film cadmium telluride and triple junction amorphous silicon solar cells. The verification of availability and stability of the proposed system through the real-time simulator shows that the proposed system can respond accurately for different scenarios and different solar cell technologies. (author)

  2. China: the tipping point in tobacco control.

    Science.gov (United States)

    Mackay, Judith

    2016-12-01

    Tobacco control in China, the world's largest producer and consumer of tobacco, began in the 1980s with the first national prevalence survey and a conference on tobacco held in Tianjin. Since then, there have been dozens of research papers, partial restrictions on smoking and tobacco advertising, public education campaigns, and the ratification of the World Health Organization Framework Convention on Tobacco Control, but progress has been slow. The state-owned tobacco industry remains a major obstacle to tobacco control. In the last few years, tobacco control efforts have accelerated beyond expectations. The triggering event was the publication on tobacco by the Chinese Central Party School, the ideological think tank of the Communist Party, followed by a spate of activity: directives to government officials; regulations issued by the Ministry of Education, the People's Liberation Army and the Healthy City Standards; tobacco clauses in national advertising and philanthropy laws; the creation of a Smoke-free Beijing; an increase in tobacco taxation; and a national smoke-free law currently in draft. There is a crucial need for China to build upon these recent developments, in accepting the economic research evidence of the debit of tobacco to the economy; in implementing robust, comprehensive legislation; in increasing cigarette price through taxation and, most challenging of all, to tackle the power and influence of the state tobacco monopoly over tobacco control. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Free-time and fixed end-point multi-target optimal control theory: Application to quantum computing

    International Nuclear Information System (INIS)

    Mishima, K.; Yamashita, K.

    2011-01-01

    Graphical abstract: The two-state Deutsch-Jozsa algortihm used to demonstrate the utility of free-time and fixed-end point multi-target optimal control theory. Research highlights: → Free-time and fixed-end point multi-target optimal control theory (FRFP-MTOCT) was constructed. → The features of our theory include optimization of the external time-dependent perturbations with high transition probabilities, that of the temporal duration, the monotonic convergence, and the ability to optimize multiple-laser pulses simultaneously. → The advantage of the theory and a comparison with conventional fixed-time and fixed end-point multi-target optimal control theory (FIFP-MTOCT) are presented by comparing data calculated using the present theory with those published previously [K. Mishima, K. Yamashita, Chem. Phys. 361 (2009) 106]. → The qubit system of our interest consists of two polar NaCl molecules coupled by dipole-dipole interaction. → The calculation examples show that our theory is useful for minor adjustment of the external fields. - Abstract: An extension of free-time and fixed end-point optimal control theory (FRFP-OCT) to monotonically convergent free-time and fixed end-point multi-target optimal control theory (FRFP-MTOCT) is presented. The features of our theory include optimization of the external time-dependent perturbations with high transition probabilities, that of the temporal duration, the monotonic convergence, and the ability to optimize multiple-laser pulses simultaneously. The advantage of the theory and a comparison with conventional fixed-time and fixed end-point multi-target optimal control theory (FIFP-MTOCT) are presented by comparing data calculated using the present theory with those published previously [K. Mishima, K. Yamashita, Chem. Phys. 361, (2009), 106]. The qubit system of our interest consists of two polar NaCl molecules coupled by dipole-dipole interaction. The calculation examples show that our theory is useful for minor

  4. Control-structure interaction in precision pointing servo loops

    Science.gov (United States)

    Spanos, John T.

    1989-01-01

    The control-structure interaction problem is addressed via stability analysis of a generic linear servo loop model. With the plant described by the rigid body mode and a single elastic mode, structural flexibility is categorized into one of three types: (1) appendage, (2) in-the-loop minimum phase, and (3) in-the-loop nonminimum phase. Closing the loop with proportional-derivative (PD) control action and introducing sensor roll-off dynamics in the feedback path, stability conditions are obtained. Trade studies are conducted with modal frequency, modal participation, modal damping, loop bandwidth, and sensor bandwidth treated as free parameters. Results indicate that appendage modes are most likely to produce instability if they are near the sensor rolloff, whereas in-the-loop modes are most dangerous near the loop bandwidth. The main goal of this paper is to provide a fundamental understanding of the control-structure interaction problem so that it may benefit the design of complex spacecraft and pointing system servo loops. In this framework, the JPL Pathfinder gimbal pointer is considered as an example.

  5. Distribution majorization of corner points by reinforcement learning for moving object detection

    Science.gov (United States)

    Wu, Hao; Yu, Hao; Zhou, Dongxiang; Cheng, Yongqiang

    2018-04-01

    Corner points play an important role in moving object detection, especially in the case of free-moving camera. Corner points provide more accurate information than other pixels and reduce the computation which is unnecessary. Previous works only use intensity information to locate the corner points, however, the information that former and the last frames provided also can be used. We utilize the information to focus on more valuable area and ignore the invaluable area. The proposed algorithm is based on reinforcement learning, which regards the detection of corner points as a Markov process. In the Markov model, the video to be detected is regarded as environment, the selections of blocks for one corner point are regarded as actions and the performance of detection is regarded as state. Corner points are assigned to be the blocks which are seperated from original whole image. Experimentally, we select a conventional method which uses marching and Random Sample Consensus algorithm to obtain objects as the main framework and utilize our algorithm to improve the result. The comparison between the conventional method and the same one with our algorithm show that our algorithm reduce 70% of the false detection.

  6. Supplementary control points for reactor shutdown without access to the main control room (International Electrotechnical Commission Standard Publication 965:1989)

    International Nuclear Information System (INIS)

    Kubalek, J.; Hajek, B.

    1993-01-01

    This standard establishes the requirements for supplementary Control Points provided to enable the operating staff to shut down the reactor and maintain the plant in a safe shut-down condition when the main control room is no longer available. This standard covers the functional selection, design and organization of the man/machine interface. It also establishes requirements for procedures which systematically verify and validate the functional design of supplementary control points. The requirements reflect the application of human engineering principles as they apply to man/machine interface. This standard does not cover special emergency response centres (e.g. a Technical Support Centre). It also does not include the detailed equipment design. Unavailability of the main control room controls due to intentionally man-induced events is not considered

  7. Draught regulator with control flap lowers dew point, keeps stacks dry

    Energy Technology Data Exchange (ETDEWEB)

    Dreizler, U.; Dreizler, W.

    1982-11-30

    Draught regulators for auxiliary air are particularly important in older stacks operated with new boilers and burners. Owing to better ventilation during burner operation and standstill, the dew point of flue gases will be lowered so that water vapour condensation will be prevented. Postfitting of draught regulators will also help in stacks already damaged by condensation water. The draught regulator has a control flap for better control of auxiliary air supply.

  8. Adaptive Control for Buck Power Converter Using Fixed Point Inducting Control and Zero Average Dynamics Strategies

    Science.gov (United States)

    Hoyos Velasco, Fredy Edimer; García, Nicolás Toro; Garcés Gómez, Yeison Alberto

    In this paper, the output voltage of a buck power converter is controlled by means of a quasi-sliding scheme. The Fixed Point Inducting Control (FPIC) technique is used for the control design, based on the Zero Average Dynamics (ZAD) strategy, including load estimation by means of the Least Mean Squares (LMS) method. The control scheme is tested in a Rapid Control Prototyping (RCP) system based on Digital Signal Processing (DSP) for dSPACE platform. The closed loop system shows adequate performance. The experimental and simulation results match. The main contribution of this paper is to introduce the load estimator by means of LMS, to make ZAD and FPIC control feasible in load variation conditions. In addition, comparison results for controlled buck converter with SMC, PID and ZAD-FPIC control techniques are shown.

  9. Design of Neutral-Point Voltage Controller of a Three-level NPC Inverter with Small DC-Link Capacitors

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Munk-Nielsen, Stig; Busquets-Monge, S.

    2013-01-01

    A Neutral-Point-Clamped (NPC) three-level inverter with small dc-link capacitors is presented in this paper. The inverter requires zero average neutral-point current for stable neutral-point voltage. The small dc-link capacitors may not maintain capacitor voltage balance, even with zero neutral......-point voltage control on the basis of the continuous model. The design method for optimum performance is discussed. The implementation of the proposed modulation strategy and the controller is very simple. The controller is implemented in a 7.5 kW induction machine based drive with only 14 ìF dc-link capacitors...

  10. End point control of an actinide precipitation reactor

    International Nuclear Information System (INIS)

    Muske, K.R.

    1997-01-01

    The actinide precipitation reactors in the nuclear materials processing facility at Los Alamos National Laboratory are used to remove actinides and other heavy metals from the effluent streams generated during the purification of plutonium. These effluent streams consist of hydrochloric acid solutions, ranging from one to five molar in concentration, in which actinides and other metals are dissolved. The actinides present are plutonium and americium. Typical actinide loadings range from one to five grams per liter. The most prevalent heavy metals are iron, chromium, and nickel that are due to stainless steel. Removal of these metals from solution is accomplished by hydroxide precipitation during the neutralization of the effluent. An end point control algorithm for the semi-batch actinide precipitation reactors at Los Alamos National Laboratory is described. The algorithm is based on an equilibrium solubility model of the chemical species in solution. This model is used to predict the amount of base hydroxide necessary to reach the end point of the actinide precipitation reaction. The model parameters are updated by on-line pH measurements

  11. Interior Point Methods on GPU with application to Model Predictive Control

    DEFF Research Database (Denmark)

    Gade-Nielsen, Nicolai Fog

    The goal of this thesis is to investigate the application of interior point methods to solve dynamical optimization problems, using a graphical processing unit (GPU) with a focus on problems arising in Model Predictice Control (MPC). Multi-core processors have been available for over ten years now...... software package called GPUOPT, available under the non-restrictive MIT license. GPUOPT includes includes a primal-dual interior-point method, which supports both the CPU and the GPU. It is implemented as multiple components, where the matrix operations and solver for the Newton directions is separated...

  12. The equilibrium point hypothesis and its application to speech motor control.

    Science.gov (United States)

    Perrier, P; Ostry, D J; Laboissière, R

    1996-04-01

    In this paper, we address a number of issues in speech research in the context of the equilibrium point hypothesis of motor control. The hypothesis suggests that movements arise from shifts in the equilibrium position of the limb or the speech articulator. The equilibrium is a consequence of the interaction of central neural commands, reflex mechanisms, muscle properties, and external loads, but it is under the control of central neural commands. These commands act to shift the equilibrium via centrally specified signals acting at the level of the motoneurone (MN) pool. In the context of a model of sagittal plane jaw and hyoid motion based on the lambda version of the equilibrium point hypothesis, we consider the implications of this hypothesis for the notion of articulatory targets. We suggest that simple linear control signals may underlie smooth articulatory trajectories. We explore as well the phenomenon of intraarticulator coarticulation in jaw movement. We suggest that even when no account is taken of upcoming context, that apparent anticipatory changes in movement amplitude and duration may arise due to dynamics. We also present a number of simulations that show in different ways how variability in measured kinematics can arise in spite of constant magnitude speech control signals.

  13. Development of safe mechanism for surgical robots using equilibrium point control method.

    Science.gov (United States)

    Park, Shinsuk; Lim, Hokjin; Kim, Byeong-sang; Song, Jae-bok

    2006-01-01

    This paper introduces a novel mechanism for surgical robotic systems to generate human arm-like compliant motion. The mechanism is based on the idea of the equilibrium point control hypothesis which claims that multi-joint limb movements are achieved by shifting the limbs' equilibrium positions defined by neuromuscular activity. The equilibrium point control can be implemented on a robot manipulator by installing two actuators at each joint of the manipulator, one to control the joint position, and the other to control the joint stiffness. This double-actuator mechanism allows us to arbitrarily manipulate the stiffness (or impedance) of a robotic manipulator as well as its position. Also, the force at the end-effector can be estimated based on joint stiffness and joint angle changes without using force transducers. A two-link manipulator and a three-link manipulator with the double-actuator units have been developed, and experiments and simulation results show the potential of the proposed approach. By creating the human arm-like behavior, this mechanism can improve the performance of robot manipulators to execute stable and safe movement in surgical environments by using a simple control scheme.

  14. Analog Fixed Maximum Power Point Control for a PWM Step-downConverter for Water Pumping Installations

    DEFF Research Database (Denmark)

    Beltran, H.; Perez, E.; Chen, Zhe

    2009-01-01

    This paper describes a Fixed Maximum Power Point analog control used in a step-down Pulse Width Modulated power converter. The DC/DC converter drives a DC motor used in small water pumping installations, without any electric storage device. The power supply is provided by PV panels working around....... The proposed Optimal Power Point fix voltage control system is analyzed in comparison to other complex controls....... their maximum power point, with a fixed operating voltage value. The control circuit implementation is not only simple and cheap, but also robust and reliable. System protections and adjustments are also proposed. Simulations and hardware are reported in the paper for a 150W water pumping application system...

  15. Evaluation of the leap motion controller as a new contact-free pointing device.

    Science.gov (United States)

    Bachmann, Daniel; Weichert, Frank; Rinkenauer, Gerhard

    2014-12-24

    This paper presents a Fitts' law-based analysis of the user's performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC) is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8% for the LMC and 2.8% for the mouse device, movement times twice as large as for a mouse device and high overall effort ratings, the Leap Motion Controller's performance as an input device for everyday generic computer pointing tasks is rather limited, at least with regard to the selection recognition provided by the LMC.

  16. Supercritical CO2 Brayton cycle compression and control near the critical point

    International Nuclear Information System (INIS)

    Wright, S. A.; Fuller, R.; Noall, J.; Radel, R.; Vernon, M. E.; Pickard, P. S.

    2008-01-01

    This report describes the supercritical compression and control issues, the analysis, and the measured test results of a small-scale supercritical CO 2 (S-CO 2 ) compression test-loop. The test loop was developed by Sandia and is described in a companion paper in this conference. The results of these experiments will for the first time evaluate and experimentally demonstrate supercritical compression and the required compressor inlet control approaches on an appropriate scale in a series of test loops at Sandia National Laboratories. The Sandia effort is focused on the main compressor of a supercritical Brayton loop while a separate DOE Gen lV program focus is on studying similar behavior in re-compression Brayton cycles that have dual compressors. One of the main goals of this program is to develop and demonstrate the ability to design, operate, and control the supercritical compression process near the critical point due to highly non-linear behavior near this point. This Sandia supercritical test-loop uses a 50 kW radial compressor to pump supercritical CO 2 (S-CO 2 ) through an orifice and through a water-cooled gas-chiller. At the design point the compressor flow rate is 3.5 kg/s, the inlet pressure is 7, 690 kPa, the pressure ratio is 1.8, the inlet temperature is 305 K, and the shaft speed is 75, 000 rpm. The purpose of the loop is to study the compression and control issues near the critical point. To study compression we intend to compare the design code predictions for efficiency and change in enthalpy (or pressure ratio / head) of the radial compressor with the measured results from actual tests. In the tests the inlet flow, temperature, and pressure, will be varied around the critical point of CO 2 (Tc=304.2 K, and Pc=7.377 MPa). To study control, the test loop will use a variety of methods including inventory control, shaft speed control, and cooling water flow rate, and cooling water temperature control methods to set the compressor inlet temperature

  17. [Sacroiliac joint injury treated with oblique insertion at anatomical points: a randomized controlled trial].

    Science.gov (United States)

    Kuang, Jiayi; Li, Yuxuan; He, Yufeng; Gan, Lin; Wang, Aiming; Chen, Yanhua; Li, Xiaoting; Guo, Lin; Tang, Rongjun

    2016-04-01

    To compare the effects of oblique insertion at anatomical points and conventional acupuncture for sacroiliac joint injury. Eighty patients were randomly divided into an observation group and a control group, 40 cases in each one. In the observation group, oblique insertion therapy at anatomical points was used, and the 9 points of equal division (anatomical points) marked by palpating the anatomical symbol were treated as the insertion acupoints. In the control group, conventional acupuncture was applied, and perpendicular insertion was adopted at Huantiao (GB 30), Zhibian (BL 54) and Weizhong (BL 40), etc. In the two groups, the! treatment was given once a day and 5 times per week. Ten treatments were made into one course and two courses were required. The clinical effects, the changes of visual analogue scale (VAS) and Oswestry dysfunctional index. (ODI) before and after treatment were observed in the two groups. The total effective rate of the observation group was 90.0% (36/40), which was better than 72.5% (29/40) of the control group (P sacroiliac joint injury is superior to that of conventional acupuncture, which can effectively relieve pain and improve the disfunction.

  18. A consideration about major business control system for independent administrative institution

    International Nuclear Information System (INIS)

    Abe, Shinya; Nakata, Yutaka; Iitsuka, Tomoaki; Yamagishi, Kojiro

    2003-10-01

    Japanese government is carrying out the administrative reform aiming to promote decentralization of authority, to magnify the field of private sectors, etc. in order to corresponds appropriately to matured economy, internationalized market, etc. As one of the reforms, Japanese government decided that JAERI and JNC would unite into an independent administrative agency. The aims of the independent administrative agency institution include realization of effective and transparent system and management. The aim of the present investigation is to be useful for the new agency to develop a major business control system, which manages financial affairs and accounts not only efficiently but also in correspondence with open information to the public and promoting research activities effectively. First of all, the authors examined Japanese laws and standards relating to the independent administrative agency. They investigated the financial affairs and accounts systems of the preceding independent administrative agencies for research and development and also the development trends of work-flow systems in private enterprises in Japan. They considered expected problems and solutions for developing and making use of the major business control system. On the basis of the above investigations, the authors revealed the total concept of the best major business control system of the new unified agency besides the necessary conditions of the system for an independent administrative agency. Additionally, the above mentioned laws and standards are collected in an appendix. (author)

  19. Pain perception in major depressive disorder: a neurophysiological case-control study.

    Science.gov (United States)

    Zambito Marsala, Sandro; Pistacchi, Michele; Tocco, Pierluigi; Gioulis, Manuela; Fabris, Federico; Brigo, Francesco; Tinazzi, Michele

    2015-10-15

    Depression and pain may sometimes be related conditions. Occasionally, depression may be associated with physical symptoms, such as back pain and headache. Moreover, depression may impair the subjective response to pain and is likely to influence the pain feeling. Conversely, chronic pain may represent an emotional condition as well as physical sensation, and can influence both the mood and behaviour. To better understand the relationship between pain and depression, we therefore assessed the pain threshold and the tolerance pain threshold in patients with depressive disorders. We conducted a case-control study and selected patients who had recently received a diagnosis of major depression (DSM-IV), before treatment, and without any significant pain complaints. Age- and sex-matched healthy controls were also included. Tactile and pain thresholds were assessed in all subjects through an electrical stimulation test. All results were compared between the groups. 27 patients and 27 age-matched healthy controls were included in the study. Tactile, pain and tolerance thresholds were evaluated in all subjects. The pain threshold and pain tolerance were lower in patients with major depression than controls. All differences were statistically significant (pdepressive disorders. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Seafood safety: economics of hazard analysis and Critical Control Point (HACCP) programmes

    National Research Council Canada - National Science Library

    Cato, James C

    1998-01-01

    .... This document on economic issues associated with seafood safety was prepared to complement the work of the Service in seafood technology, plant sanitation and Hazard Analysis Critical Control Point (HACCP) implementation...

  1. An energy-saving set-point optimizer with a sliding mode controller for automotive air-conditioning/refrigeration systems

    International Nuclear Information System (INIS)

    Huang, Yanjun; Khajepour, Amir; Ding, Haitao; Bagheri, Farshid; Bahrami, Majid

    2017-01-01

    Highlights: • A novel two-layer energy-saving controller for automotive A/C-R system is developed. • A set-point optimizer at the outer loop is designed based on the steady state model. • A sliding mode controller in the inner loop is built. • Extensively experiments studies show that about 9% energy can be saving by this controller. - Abstract: This paper presents an energy-saving controller for automotive air-conditioning/refrigeration (A/C-R) systems. With their extensive application in homes, industry, and vehicles, A/C-R systems are consuming considerable amounts of energy. The proposed controller consists of two different time-scale layers. The outer or the slow time-scale layer called a set-point optimizer is used to find the set points related to energy efficiency by using the steady state model; whereas, the inner or the fast time-scale layer is used to track the obtained set points. In the inner loop, thanks to its robustness, a sliding mode controller (SMC) is utilized to track the set point of the cargo temperature. The currently used on/off controller is presented and employed as a basis for comparison to the proposed controller. More importantly, the real experimental results under several disturbed scenarios are analysed to demonstrate how the proposed controller can improve performance while reducing the energy consumption by 9% comparing with the on/off controller. The controller is suitable for any type of A/C-R system even though it is applied to an automotive A/C-R system in this paper.

  2. 41 CFR 101-26.606 - Supply support available from the inventory control points of the military departments.

    Science.gov (United States)

    2010-07-01

    ... from the inventory control points of the military departments. 101-26.606 Section 101-26.606 Public... § 101-26.606 Supply support available from the inventory control points of the military departments. Federal civil agencies may obtain items of supply which are procured and managed by the inventory control...

  3. Maximum Power Point Tracking Based on Sliding Mode Control

    Directory of Open Access Journals (Sweden)

    Nimrod Vázquez

    2015-01-01

    Full Text Available Solar panels, which have become a good choice, are used to generate and supply electricity in commercial and residential applications. This generated power starts with the solar cells, which have a complex relationship between solar irradiation, temperature, and output power. For this reason a tracking of the maximum power point is required. Traditionally, this has been made by considering just current and voltage conditions at the photovoltaic panel; however, temperature also influences the process. In this paper the voltage, current, and temperature in the PV system are considered to be a part of a sliding surface for the proposed maximum power point tracking; this means a sliding mode controller is applied. Obtained results gave a good dynamic response, as a difference from traditional schemes, which are only based on computational algorithms. A traditional algorithm based on MPPT was added in order to assure a low steady state error.

  4. Improvement of lithium chloride dew-point hygrometer for direct reading and controlling of relative humidity

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X.Z.; Chu, Y.

    1986-01-01

    The lithium chloride dew-point hygrometer has many advantages over other types of hygrometers. However, it only reads and controls the dew-point temperature of air instead of the relative humidity, which is more important in industry, agriculture, food storage, and hygiene. This paper describes a new hygrometer which is based on the same principle as the lithium chloride dew-point hygrometer, but it can read and control the relative humidity directly. The instrument is quick in response and the ranges of temperature and relative humidity are quite large. Its accuracy is normally within 3% RH and its precision is within 2% RH.

  5. Sliding-Mode Controller for Maximum Power Point Tracking in Grid-Connected Photovoltaic Systems

    Directory of Open Access Journals (Sweden)

    Paula Andrea Ortiz Valencia

    2015-11-01

    Full Text Available The maximum power point tracking (MPPT of photovoltaic systems must be as fast and accurate as possible to increase the power production, which eventually increases the PV system profitability. This paper proposes and mathematically analyses a sliding-mode controller to provide a fast and accurate maximum power point tracking in grid-connected photovoltaic systems using a single control stage. This approach avoids the circular dependency in the design of classical cascade controllers used to optimize the photovoltaic system operation, and at the same time, it reduces the number of controllers and avoids the use of linearized models to provide global stability in all the operation range. Such a compact solution also reduces the system cost and implementation complexity. To ensure the stability of the proposed solution, detailed mathematical analyses are performed to demonstrate the fulfillment of the transversality, reachability and equivalent control conditions. Finally, the performance of the proposed solution is validated using detailed simulations, executed in the power electronics simulator PSIM, accounting for both environmental and load perturbations.

  6. Interference control in children with first episode major depression : A brief report

    NARCIS (Netherlands)

    van der Meere, Jaap; Börger, Norbert A.; Pirila, Silja; Sallee, Floyed

    2011-01-01

    The ability to deal with sources of conflict, that is, interference control, was evaluated in a group of 11 children with first episode Major Depression and a peer control group. To this end, the Eriksen and Schultz (1979) task was used. Here, the participant is presented with a stimulus that

  7. Application of hazard analysis critical control points (HACCP) to organic chemical contaminants in food.

    Science.gov (United States)

    Ropkins, K; Beck, A J

    2002-03-01

    Hazard Analysis Critical Control Points (HACCP) is a systematic approach to the identification, assessment, and control of hazards that was developed as an effective alternative to conventional end-point analysis to control food safety. It has been described as the most effective means of controlling foodborne diseases, and its application to the control of microbiological hazards has been accepted internationally. By contrast, relatively little has been reported relating to the potential use of HACCP, or HACCP-like procedures, to control chemical contaminants of food. This article presents an overview of the implementation of HACCP and discusses its application to the control of organic chemical contaminants in the food chain. Although this is likely to result in many of the advantages previously identified for microbiological HACCP, that is, more effective, efficient, and economical hazard management, a number of areas are identified that require further research and development. These include: (1) a need to refine the methods of chemical contaminant identification and risk assessment employed, (2) develop more cost-effective monitoring and control methods for routine chemical contaminant surveillance of food, and (3) improve the effectiveness of process optimization for the control of chemical contaminants in food.

  8. Magnetic-field control of quantum critical points of valence transition.

    Science.gov (United States)

    Watanabe, Shinji; Tsuruta, Atsushi; Miyake, Kazumasa; Flouquet, Jacques

    2008-06-13

    We study the mechanism of how critical end points of first-order valence transitions are controlled by a magnetic field. We show that the critical temperature is suppressed to be a quantum critical point (QCP) by a magnetic field, and unexpectedly, the QCP exhibits nonmonotonic field dependence in the ground-state phase diagram, giving rise to the emergence of metamagnetism even in the intermediate valence-crossover regime. The driving force of the field-induced QCP is clarified to be cooperative phenomena of the Zeeman and Kondo effects, which create a distinct energy scale from the Kondo temperature. This mechanism explains the peculiar magnetic response in CeIrIn(5) and the metamagnetic transition in YbXCu(4) for X=In as well as the sharp contrast between X=Ag and Cd.

  9. Nonlinear Burn Control and Operating Point Optimization in ITER

    Science.gov (United States)

    Boyer, Mark; Schuster, Eugenio

    2013-10-01

    Control of the fusion power through regulation of the plasma density and temperature will be essential for achieving and maintaining desired operating points in fusion reactors and burning plasma experiments like ITER. In this work, a volume averaged model for the evolution of the density of energy, deuterium and tritium fuel ions, alpha-particles, and impurity ions is used to synthesize a multi-input multi-output nonlinear feedback controller for stabilizing and modulating the burn condition. Adaptive control techniques are used to account for uncertainty in model parameters, including particle confinement times and recycling rates. The control approach makes use of the different possible methods for altering the fusion power, including adjusting the temperature through auxiliary heating, modulating the density and isotopic mix through fueling, and altering the impurity density through impurity injection. Furthermore, a model-based optimization scheme is proposed to drive the system as close as possible to desired fusion power and temperature references. Constraints are considered in the optimization scheme to ensure that, for example, density and beta limits are avoided, and that optimal operation is achieved even when actuators reach saturation. Supported by the NSF CAREER award program (ECCS-0645086).

  10. A new lunar absolute control point: established by images from the landing camera on Chang'e-3

    International Nuclear Information System (INIS)

    Wang Fen-Fei; Liu Jian-Jun; Li Chun-Lai; Ren Xin; Mu Ling-Li; Yan Wei; Wang Wen-Rui; Xiao Jing-Tao; Tan Xu; Zhang Xiao-Xia; Zou Xiao-Duan; Gao Xing-Ye

    2014-01-01

    The establishment of a lunar control network is one of the core tasks in selenodesy, in which defining an absolute control point on the Moon is the most important step. However, up to now, the number of absolute control points has been very sparse. These absolute control points have mainly been lunar laser ranging retroreflectors, whose geographical location can be observed by observations on Earth and also identified in high resolution lunar satellite images. The Chang'e-3 (CE-3) probe successfully landed on the Moon, and its geographical location has been monitored by an observing station on Earth. Since its positional accuracy is expected to reach the meter level, the CE-3 landing site can become a new high precision absolute control point. We use a sequence of images taken from the landing camera, as well as satellite images taken by CE-1 and CE-2, to identify the location of the CE-3 lander. With its geographical location known, the CE-3 landing site can be established as a new absolute control point, which will effectively expand the current area of the lunar absolute control network by 22%, and can greatly facilitate future research in the field of lunar surveying and mapping, as well as selenodesy

  11. Articulating the history and major departure points evident in post-apartheid South African national water policy and law

    Science.gov (United States)

    Chikozho, C.; Danga, L.; Saruchera, D.

    2017-08-01

    Governance of the water sector in South Africa has reflected the political changes taking place in society. For instance, due to apartheid policies of segregation, inequality of access to water resources marks South Africa's history in a very profound way and redistribution of rights to water to redress the results of past discrimination became an explicit purpose of the post-apartheid water governance policy and legislative regime. In this paper, we articulate the history and major departure points evident in post-apartheid South African national water policy and law. This includes documenting and reflecting on most of the available information that shows how the new water policy and law were developed. Findings from the study show that the key players active in the water law review process deliberately took into account the political goals and dynamics of power asymmetry within which the law was being articulated. Therefore, the water law as it stands today and in the past must be understood within the context of the socio-economic and political landscape that has prevailed in South Africa at different historical junctures. We contend that a detailed examination and articulation of the history and major departure points evident in post-apartheid South African national water policy and law enables practitioners and scholars to better understand the main motivations behind the water sector reforms and the then prevailing thinking behind the policy and legislation eventually promulgated. The present water law must be understood in the context of these reforms and the objectives they sought to achieve.

  12. Compensation for loads during arm movements using equilibrium-point control.

    Science.gov (United States)

    Gribble, P L; Ostry, D J

    2000-12-01

    A significant problem in motor control is how information about movement error is used to modify control signals to achieve desired performance. A potential source of movement error and one that is readily controllable experimentally relates to limb dynamics and associated movement-dependent loads. In this paper, we have used a position control model to examine changes to control signals for arm movements in the context of movement-dependent loads. In the model, based on the equilibrium-point hypothesis, equilibrium shifts are adjusted directly in proportion to the positional error between desired and actual movements. The model is used to simulate multi-joint movements in the presence of both "internal" loads due to joint interaction torques, and externally applied loads resulting from velocity-dependent force fields. In both cases it is shown that the model can achieve close correspondence to empirical data using a simple linear adaptation procedure. An important feature of the model is that it achieves compensation for loads during movement without the need for either coordinate transformations between positional error and associated corrective forces, or inverse dynamics calculations.

  13. An international point source outbreak of typhoid fever: a European collaborative investigation*

    Science.gov (United States)

    Stanwell-Smith, R. E.; Ward, L. R.

    1986-01-01

    A point source outbreak of Salmonella typhi, degraded Vi-strain 22, affecting 32 British visitors to Kos, Greece, in 1983 was attributed by a case—control study to the consumption of a salad at one hotel. This represents the first major outbreak of typhoid fever in which a salad has been identified as the vehicle. The source of the infection was probably a carrier in the hotel staff. The investigation demonstrates the importance of national surveillance, international cooperation, and epidemiological methods in the investigation and control of major outbreaks of infection. PMID:3488842

  14. Hygienic-sanitary working practices and implementation of a Hazard Analysis and Critical Control Point (HACCP plan in lobster processing industries

    Directory of Open Access Journals (Sweden)

    Cristina Farias da Fonseca

    2013-03-01

    Full Text Available This study aimed to verify the hygienic-sanitary working practices and to create and implement a Hazard Analysis Critical Control Point (HACCP in two lobster processing industries in Pernambuco State, Brazil. The industries studied process frozen whole lobsters, frozen whole cooked lobsters, and frozen lobster tails for exportation. The application of the hygienic-sanitary checklist in the industries analyzed achieved conformity rates over 96% to the aspects evaluated. The use of the Hazard Analysis Critical Control Point (HACCP plan resulted in the detection of two critical control points (CCPs including the receiving and classification steps in the processing of frozen lobster and frozen lobster tails, and an additional critical control point (CCP was detected during the cooking step of processing of the whole frozen cooked lobster. The proper implementation of the Hazard Analysis Critical Control Point (HACCP plan in the lobster processing industries studied proved to be the safest and most cost-effective method to monitor each critical control point (CCP hazards.

  15. Single-point reactive power control method on voltage rise mitigation in residential networks with high PV penetration

    DEFF Research Database (Denmark)

    Hasheminamin, Maryam; Agelidis, Vassilios; Ahmadi, Abdollah

    2018-01-01

    Voltage rise (VR) due to reverse power flow is an important obstacle for high integration of Photovoltaic (PV) into residential networks. This paper introduces and elaborates a novel methodology of an index-based single-point-reactive power-control (SPRPC) methodology to mitigate voltage rise by ...... system with high r/x ratio. Efficacy, effectiveness and cost study of SPRPC is compared to droop control to evaluate its advantages.......Voltage rise (VR) due to reverse power flow is an important obstacle for high integration of Photovoltaic (PV) into residential networks. This paper introduces and elaborates a novel methodology of an index-based single-point-reactive power-control (SPRPC) methodology to mitigate voltage rise...... by absorbing adequate reactive power from one selected point. The proposed index utilizes short circuit analysis to select the best point to apply this Volt/Var control method. SPRPC is supported technically and financially by distribution network operator that makes it cost effective, simple and efficient...

  16. Choosing the Optimal Number of B-spline Control Points (Part 1: Methodology and Approximation of Curves)

    Science.gov (United States)

    Harmening, Corinna; Neuner, Hans

    2016-09-01

    Due to the establishment of terrestrial laser scanner, the analysis strategies in engineering geodesy change from pointwise approaches to areal ones. These areal analysis strategies are commonly built on the modelling of the acquired point clouds. Freeform curves and surfaces like B-spline curves/surfaces are one possible approach to obtain space continuous information. A variety of parameters determines the B-spline's appearance; the B-spline's complexity is mostly determined by the number of control points. Usually, this number of control points is chosen quite arbitrarily by intuitive trial-and-error-procedures. In this paper, the Akaike Information Criterion and the Bayesian Information Criterion are investigated with regard to a justified and reproducible choice of the optimal number of control points of B-spline curves. Additionally, we develop a method which is based on the structural risk minimization of the statistical learning theory. Unlike the Akaike and the Bayesian Information Criteria this method doesn't use the number of parameters as complexity measure of the approximating functions but their Vapnik-Chervonenkis-dimension. Furthermore, it is also valid for non-linear models. Thus, the three methods differ in their target function to be minimized and consequently in their definition of optimality. The present paper will be continued by a second paper dealing with the choice of the optimal number of control points of B-spline surfaces.

  17. The application of hazard analysis and critical control points and risk management in the preparation of anti-cancer drugs.

    Science.gov (United States)

    Bonan, Brigitte; Martelli, Nicolas; Berhoune, Malik; Maestroni, Marie-Laure; Havard, Laurent; Prognon, Patrice

    2009-02-01

    To apply the Hazard analysis and Critical Control Points method to the preparation of anti-cancer drugs. To identify critical control points in our cancer chemotherapy process and to propose control measures and corrective actions to manage these processes. The Hazard Analysis and Critical Control Points application began in January 2004 in our centralized chemotherapy compounding unit. From October 2004 to August 2005, monitoring of the process nonconformities was performed to assess the method. According to the Hazard Analysis and Critical Control Points method, a multidisciplinary team was formed to describe and assess the cancer chemotherapy process. This team listed all of the critical points and calculated their risk indexes according to their frequency of occurrence, their severity and their detectability. The team defined monitoring, control measures and corrective actions for each identified risk. Finally, over a 10-month period, pharmacists reported each non-conformity of the process in a follow-up document. Our team described 11 steps in the cancer chemotherapy process. The team identified 39 critical control points, including 11 of higher importance with a high-risk index. Over 10 months, 16,647 preparations were performed; 1225 nonconformities were reported during this same period. The Hazard Analysis and Critical Control Points method is relevant when it is used to target a specific process such as the preparation of anti-cancer drugs. This method helped us to focus on the production steps, which can have a critical influence on product quality, and led us to improve our process.

  18. Quality assurance and halal control points for the food industry

    OpenAIRE

    Lau, An Nee; Jamaludin, Mohd Hafiz; Soon, Jan Mei

    2016-01-01

    Purpose\\ud To determine the understanding of halal concept among food production workers and to develop a generic Halal Control Point (HCP) Plan for the manufacturing of processed foods.\\ud \\ud Design/methodology/approach\\ud A mixed method (interviews, surveys and microbiological analyses) approach was used to analyze the hygiene and halal practices of four food processing plants in Penang, Malaysia. Two hundred food production workers were surveyed (and quality assurance staff were interview...

  19. Tool for identifying critical control points in embedded purchasing activities in SMEs

    NARCIS (Netherlands)

    Hagelaar, Geoffrey; Staal, Anne; Holman, Richard; Walhof, Gert

    2015-01-01

    This paper discusses risk and uncertainty aspects and proposes an assessment tool leading to identification of critical control points (CCPs) within purchasing-oriented activities of small and medium enterprises (SMEs). Identifying such CCPs is the basis for developing SME purchasing instruments to

  20. Critical control points for the management of microbial growth in HVAC systems

    NARCIS (Netherlands)

    Gommers, S; Franchimon, F.; Bronswijk, van J.E.M.H.; Strøm-Tejsen, P; Olesen, BW; Wargocki, P; Zukowska, D; Toftum, J

    2008-01-01

    Office buildings with HVAC systems consistently report Sick Building Symptoms that are derived from microbial growth. We used the HACCP methodology to find the main critical control points (CCPs) for microbial management of HVAC systems in temperate climates. Desk research revealed relative humidity

  1. Optimized Adaptive Perturb and Observe Maximum Power Point Tracking Control for Photovoltaic Generation

    Directory of Open Access Journals (Sweden)

    Luigi Piegari

    2015-04-01

    Full Text Available The power extracted from PV arrays is usually maximized using maximum power point tracking algorithms. One of the most widely used techniques is the perturb & observe algorithm, which periodically perturbs the operating point of the PV array, sometime with an adaptive perturbation step, and compares the PV power before and after the perturbation. This paper analyses the most suitable perturbation step to optimize maximum power point tracking performance and suggests a design criterion to select the parameters of the controller. Using this proposed adaptive step, the MPPT perturb & observe algorithm achieves an excellent dynamic response by adapting the perturbation step to the actual operating conditions of the PV array. The proposed algorithm has been validated and tested in a laboratory using a dual input inductor push-pull converter. This particular converter topology is an efficient interface to boost the low voltage of PV arrays and effectively control the power flow when input or output voltages are variable. The experimental results have proved the superiority of the proposed algorithm in comparison of traditional perturb & observe and incremental conductance techniques.

  2. Equilibrium-point control hypothesis examined by measured arm stiffness during multijoint movement.

    Science.gov (United States)

    Gomi, H; Kawato

    1996-04-05

    For the last 20 years, it has been hypothesized that well-coordinated, multijoint movements are executed without complex computation by the brain, with the use of springlike muscle properties and peripheral neural feedback loops. However, it has been technically and conceptually difficult to examine this "equilibrium-point control" hypothesis directly in physiological or behavioral experiments. A high-performance manipulandum was developed and used here to measure human arm stiffness, the magnitude of which during multijoint movement is important for this hypothesis. Here, the equilibrium-point trajectory was estimated from the measured stiffness, the actual trajectory, and the generated torque. Its velocity profile differed from that of the actual trajectory. These results argue against the hypothesis that the brain sends as a motor command only an equilibrium-point trajectory similar to the actual trajectory.

  3. A Riccati-Based Interior Point Method for Efficient Model Predictive Control of SISO Systems

    DEFF Research Database (Denmark)

    Hagdrup, Morten; Johansson, Rolf; Bagterp Jørgensen, John

    2017-01-01

    model parts separate. The controller is designed based on the deterministic model, while the Kalman filter results from the stochastic part. The controller is implemented as a primal-dual interior point (IP) method using Riccati recursion and the computational savings possible for SISO systems...

  4. Macro-mechanics controls quantum mechanics: mechanically controllable quantum conductance switching of an electrochemically fabricated atomic-scale point contact.

    Science.gov (United States)

    Staiger, Torben; Wertz, Florian; Xie, Fangqing; Heinze, Marcel; Schmieder, Philipp; Lutzweiler, Christian; Schimmel, Thomas

    2018-01-12

    Here, we present a silver atomic-scale device fabricated and operated by a combined technique of electrochemical control (EC) and mechanically controllable break junction (MCBJ). With this EC-MCBJ technique, we can perform mechanically controllable bistable quantum conductance switching of a silver quantum point contact (QPC) in an electrochemical environment at room temperature. Furthermore, the silver QPC of the device can be controlled both mechanically and electrochemically, and the operating mode can be changed from 'electrochemical' to 'mechanical', which expands the operating mode for controlling QPCs. These experimental results offer the perspective that a silver QPC may be used as a contact for a nanoelectromechanical relay.

  5. Macro-mechanics controls quantum mechanics: mechanically controllable quantum conductance switching of an electrochemically fabricated atomic-scale point contact

    Science.gov (United States)

    Staiger, Torben; Wertz, Florian; Xie, Fangqing; Heinze, Marcel; Schmieder, Philipp; Lutzweiler, Christian; Schimmel, Thomas

    2018-01-01

    Here, we present a silver atomic-scale device fabricated and operated by a combined technique of electrochemical control (EC) and mechanically controllable break junction (MCBJ). With this EC-MCBJ technique, we can perform mechanically controllable bistable quantum conductance switching of a silver quantum point contact (QPC) in an electrochemical environment at room temperature. Furthermore, the silver QPC of the device can be controlled both mechanically and electrochemically, and the operating mode can be changed from ‘electrochemical’ to ‘mechanical’, which expands the operating mode for controlling QPCs. These experimental results offer the perspective that a silver QPC may be used as a contact for a nanoelectromechanical relay.

  6. Treating major depression with yoga: A prospective, randomized, controlled pilot trial.

    Directory of Open Access Journals (Sweden)

    Sudha Prathikanti

    Full Text Available Conventional pharmacotherapies and psychotherapies for major depression are associated with limited adherence to care and relatively low remission rates. Yoga may offer an alternative treatment option, but rigorous studies are few. This randomized controlled trial with blinded outcome assessors examined an 8-week hatha yoga intervention as mono-therapy for mild-to-moderate major depression.Investigators recruited 38 adults in San Francisco meeting criteria for major depression of mild-to-moderate severity, per structured psychiatric interview and scores of 14-28 on Beck Depression Inventory-II (BDI. At screening, individuals engaged in psychotherapy, antidepressant pharmacotherapy, herbal or nutraceutical mood therapies, or mind-body practices were excluded. Participants were 68% female, with mean age 43.4 years (SD = 14.8, range = 22-72, and mean BDI score 22.4 (SD = 4.5. Twenty participants were randomized to 90-minute hatha yoga practice groups twice weekly for 8 weeks. Eighteen participants were randomized to 90-minute attention control education groups twice weekly for 8 weeks. Certified yoga instructors delivered both interventions at a university clinic. Primary outcome was depression severity, measured by BDI scores every 2 weeks from baseline to 8 weeks. Secondary outcomes were self-efficacy and self-esteem, measured by scores on the General Self-Efficacy Scale (GSES and Rosenberg Self-Esteem Scale (RSES at baseline and at 8 weeks.In intent-to-treat analysis, yoga participants exhibited significantly greater 8-week decline in BDI scores than controls (p-value = 0.034. In sub-analyses of participants completing final 8-week measures, yoga participants were more likely to achieve remission, defined per final BDI score ≤ 9 (p-value = 0.018. Effect size of yoga in reducing BDI scores was large, per Cohen's d = -0.96 [95%CI, -1.81 to -0.12]. Intervention groups did not differ significantly in 8-week change scores for either the GSES or

  7. A comprehensive review of the implementation of hazard analysis critical control point (HACCP) to the production of flour and flour-based products.

    Science.gov (United States)

    Arvanitoyannis, Ioannis S; Traikou, Athina

    2005-01-01

    The production of flour and semolina and their ensuing products, such as bread, cake, spaghetti, noodles, and corn flakes, is of major importance, because these products constitute some of the main ingredients of the human diet. The Hazard Analysis Critical Control Point (HACCP) system aims at ensuring the safety of these products. HACCP has been implemented within the frame of this study on various products of both Asian and European origin; the hazards, critical control limits (CCLs), observation practices, and corrective actions have been summarized in comprehensive tables. Furthermore, the various production steps, packaging included, were thoroughly analyzed, and reference was made to both the traditional and new methodologies in an attempt to pinpoint the occurring differences (advantages and disadvantages) per process.

  8. Control of the electrical operating point of an electric discharge by mean of its power supply; Controle du point de fonctionnement des decharges electriques par l'intermediaire de leur alimentation

    Energy Technology Data Exchange (ETDEWEB)

    Salanne, J.Ph.

    2005-11-15

    The operating points obtained by the coupling of the power supply with the electric discharge system can be unstable because of the dynamical behaviour of the discharge or because of a change in its length. In this work, the different possible couplings existing between the discharge and the characteristics of its power supply are analyzed in order to optimize the design and control of the power supply and to control the operating point. Analytical and numerical modeling of the system are proposed which allow to simulate the couplings between the power supply and the discharge. This approach is completed by experimental investigations allowing to consider the cases of peak/peak discharges, dielectric barrier discharges (DBD), and gliding arcs. (J.S.)

  9. The Hazard Analysis and Critical Control Points (HACCP) generic model for the production of Thai fermented pork sausage (Nham).

    Science.gov (United States)

    Paukatong, K V; Kunawasen, S

    2001-01-01

    Nham is a traditional Thai fermented pork sausage. The major ingredients of Nham are ground pork meat and shredded pork rind. Nham has been reported to be contaminated with Salmonella spp., Staphylococcus aureus, and Listeria monocytogenes. Therefore, it is a potential cause of foodborne diseases for consumers. A Hazard Analysis and Critical Control Points (HACCP) generic model has been developed for the Nham process. Nham processing plants were observed and a generic flow diagram of Nham processes was constructed. Hazard analysis was then conducted. Other than microbial hazards, the pathogens previously found in Nham, sodium nitrite and metal were identified as chemical and physical hazards in this product, respectively. Four steps in the Nham process have been identified as critical control points. These steps are the weighing of the nitrite compound, stuffing, fermentation, and labeling. The chemical hazard of nitrite must be controlled during the weighing step. The critical limit of nitrite levels in the Nham mixture has been set at 100-200 ppm. This level is high enough to control Clostridium botulinum but does not cause chemical hazards to the consumer. The physical hazard from metal clips could be prevented by visual inspection of every Nham product during stuffing. The microbiological hazard in Nham could be reduced in the fermentation process. The critical limit of the pH of Nham was set at lower than 4.6. Since this product is not cooked during processing, finally, educating the consumer, by providing information on the label such as "safe if cooked before consumption", could be an alternative way to prevent the microbiological hazards of this product.

  10. CRITICAL CONTROL POINT IDENTIFICATION THROUGH TROPHOLOGICAL MEAT PRODUCTION CHAINFROM FIELD TO FORK

    Directory of Open Access Journals (Sweden)

    A. V. Borodin

    2017-01-01

    Full Text Available  Competitive production management is impossible without comprehensive hazard monitoring and critical parameters control at every stage of food production from raw material and auxiliary materials delivery to ready product realization, which is difficult without modern IT-support. The HACCP (Hazard Analysis and Critical Control Points approach to product safety differs from ready product testing for compliance with NaTD requirements (Normative and Technical Documentation and emphasizes the importance of the process approach to monitoring at every stage of food production. Critical control points (CCP identification is a stage, where the presence of a risk of manufacturing products that are unsafe for human health is recognized and it is possible to take action to its elimination, prevention or reduction to an acceptable level. The use of soſtware package significantly increases the enterprise HACCP system efficiency. The article describes methodological bases for IT-approach to the CCP identification in the trophological meat production chain from field to fork. The algorithmic support and soſtware for the «Decision tree», which allows detecting existing hazards, identifying risks, determining CCPs and describing them, has been developed.

  11. Two-point method uncertainty during control and measurement of cylindrical element diameters

    Science.gov (United States)

    Glukhov, V. I.; Shalay, V. V.; Radev, H.

    2018-04-01

    The topic of the article is devoted to the urgent problem of the reliability of technical products geometric specifications measurements. The purpose of the article is to improve the quality of parts linear sizes control by the two-point measurement method. The article task is to investigate methodical extended uncertainties in measuring cylindrical element linear sizes. The investigation method is a geometric modeling of the element surfaces shape and location deviations in a rectangular coordinate system. The studies were carried out for elements of various service use, taking into account their informativeness, corresponding to the kinematic pairs classes in theoretical mechanics and the number of constrained degrees of freedom in the datum element function. Cylindrical elements with informativity of 4, 2, 1 and θ (zero) were investigated. The uncertainties estimation of in two-point measurements was made by comparing the results of of linear dimensions measurements with the functional diameters maximum and minimum of the element material. Methodical uncertainty is formed when cylindrical elements with maximum informativeness have shape deviations of the cut and the curvature types. Methodical uncertainty is formed by measuring the element average size for all types of shape deviations. The two-point measurement method cannot take into account the location deviations of a dimensional element, so its use for elements with informativeness less than the maximum creates unacceptable methodical uncertainties in measurements of the maximum, minimum and medium linear dimensions. Similar methodical uncertainties also exist in the arbitration control of the linear dimensions of the cylindrical elements by limiting two-point gauges.

  12. Effectiveness of Aerobic Exercise as an Augmentation Therapy for Inpatients with Major Depressive Disorder: A Preliminary Randomized Controlled Trial.

    Science.gov (United States)

    Shachar-Malach, Tal; Cooper Kazaz, Rena; Constantini, Naama; Lifschytz, Tzuri; Lerer, Bernard

    2015-01-01

    Physical exercise has been shown to reduce depressive symptoms when used in combination with antidepressant medication. We report a randomized controlled trial of aerobic exercise compared to stretching as an augmentation strategy for hospitalized patients with major depression. Male or female patients, 18-80 years, diagnosed with a Major Depressive Episode, were randomly assigned to three weeks of augmentation therapy with aerobic (n=6) or stretching exercise (n=6). Depression was rated, at several time points using the 21-item Hamilton Depression Scale (HAM-D), Beck Depression Inventory (BDI) and other scales. According to the HAM-D, there were four (out of six) responders in the aerobic group, two of whom achieved remission, and none in the stretching group. According to the BDI, there were two responders in the aerobic group who were also remitters and none in the stretching group. The results of this small study suggest that aerobic exercise significantly improves treatment outcome when added to antidepressant medication. However, due to the small sample size the results must be regarded as preliminary and further studies are needed to confirm the findings.

  13. A Flexible VHDL Floating Point Module for Control Algorithm Implementation in Space Applications

    Science.gov (United States)

    Padierna, A.; Nicoleau, C.; Sanchez, J.; Hidalgo, I.; Elvira, S.

    2012-08-01

    The implementation of control loops for space applications is an area with great potential. However, the characteristics of this kind of systems, such as its wide dynamic range of numeric values, make inadequate the use of fixed-point algorithms.However, because the generic chips available for the treatment of floating point data are, in general, not qualified to operate in space environments and the possibility of using an IP module in a FPGA/ASIC qualified for space is not viable due to the low amount of logic cells available for these type of devices, it is necessary to find a viable alternative.For these reasons, in this paper a VHDL Floating Point Module is presented. This proposal allows the design and execution of floating point algorithms with acceptable occupancy to be implemented in FPGAs/ASICs qualified for space environments.

  14. Perturb and Observe Control for an Embedded Point Pivoted Absorber

    Directory of Open Access Journals (Sweden)

    Gianluca Brando

    2016-11-01

    Full Text Available Marine energy sources represent an attractive and inexhaustible reservoir able to contribute to the fulfillment of the world energy demand in accordance with climate/energy regulatory frameworks. Wave energy converter (WEC integration into the main grid requires both the maximization of the harvested energy and the proper management of the generation variability. The present paper focuses on both these mentioned issues. More specifically, it presents an embedded point pivoted absorber (PPA and its related control strategy aimed at maximizing the harvested energy. Experimental and numerical investigations have been carried out in a wave/towing tank facility in order to derive the design characteristics of the full-scale model and demonstrate the validity and effectiveness of the proposed control strategy.

  15. Evaluation of the Leap Motion Controller as a New Contact-Free Pointing Device

    Directory of Open Access Journals (Sweden)

    Daniel Bachmann

    2014-12-01

    Full Text Available This paper presents a Fitts’ law-based analysis of the user’s performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8% for the LMC and 2.8% for the mouse device, movement times twice as large as for a mouse device and high overall effort ratings, the Leap Motion Controller’s performance as an input device for everyday generic computer pointing tasks is rather limited, at least with regard to the selection recognition provided by the LMC.

  16. Quality Assurance and Quality Control in Point-of-Care Testing.

    Science.gov (United States)

    Newman, Ashleigh W; Behling-Kelly, Erica

    2016-03-01

    With advancements in the standard of care in veterinary medicine and instrument technology, performing in-house laboratory work on a variety of point-of-care instruments, ranging from glucometers to benchtop chemistry analyzers, has become increasingly commonplace. However, the ability of an instrument to perform a test does not guarantee that those results are accurate. Ensuring that your in-clinic laboratory is providing reliable data requires a comprehensive plan that encompasses both common sense practices aimed at preventing errors at each stage of the testing process, as well as standard operating procedures to validate and monitor analyzer performance. These 2 arms of the plan are known as quality assurance and quality control. Although these concepts are typically out of the comfort zone for veterinarians, just as the thought of business management may deter some veterinarians from practice ownership, it is not beyond the capabilities of veterinarians to learn, understand, and incorporate them into their practice. The objectives of this article are to convey the importance of quality assurance and quality control, walk you through the American Society for Veterinary Clinical Pathology guidelines on this topic, and provide direction to additional resources for further education on this topic, all with the focus on point-of-care testing in the in-clinic laboratory. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Velocity-based planning of rapid elbow movements expands the control scheme of the equilibrium point hypothesis.

    Science.gov (United States)

    Suzuki, Masataka; Yamazaki, Yoshihiko

    2005-01-01

    According to the equilibrium point hypothesis of voluntary motor control, control action of muscles is not explicitly computed, but rather arises as a consequence of interaction between moving equilibrium position, current kinematics and stiffness of the joint. This approach is attractive as it obviates the need to explicitly specify the forces controlling limb movements. However, many debatable aspects of this hypothesis remain in the manner of specification of the equilibrium point trajectory and muscle activation (or its stiffness), which elicits a restoring force toward the planned equilibrium trajectory. In this study, we expanded the framework of this hypothesis by assuming that the control system uses the velocity measure as the origin of subordinate variables scaling descending commands. The velocity command is translated into muscle control inputs by second order pattern generators, which yield reciprocal command and coactivation commands, and create alternating activation of the antagonistic muscles during movement and coactivation in the post-movement phase, respectively. The velocity command is also integrated to give a position command specifying a moving equilibrium point. This model is purely kinematics-dependent, since the descending commands needed to modulate the visco-elasticity of muscles are implicitly given by simple parametric specifications of the velocity command alone. The simulated movements of fast elbow single-joint movements corresponded well with measured data performed over a wide range of movement distances, in terms of both muscle excitations and kinematics. Our proposal on a synthesis for the equilibrium point approach and velocity command, may offer some insights into the control scheme of the single-joint arm movements.

  18. Developing control points for halal slaughtering of poultry.

    Science.gov (United States)

    Shahdan, I A; Regenstein, J M; Shahabuddin, A S M; Rahman, M T

    2016-07-01

    Halal (permissible or lawful) poultry meat production must meet industry, economic, and production needs, and government health requirements without compromising the Islamic religious requirements derived from the Qur'an and the Hadiths (the actions and sayings of the Prophet Muhammad, peace and blessings be upon him). Halal certification authorities may vary in their interpretation of these teachings, which leads to differences in halal slaughter requirements. The current study proposes 6 control points (CP) for halal poultry meat production based on the most commonly used halal production systems. CP 1 describes what is allowed and prohibited, such as blood and animal manure, and feed ingredients for halal poultry meat production. CP 2 describes the requirements for humane handling during lairage. CP 3 describes different methods for immobilizing poultry, when immobilization is used, such as water bath stunning. CP 4 describes the importance of intention, details of the halal slaughter, and the equipment permitted. CP 5 and CP 6 describe the requirements after the neck cut has been made such as the time needed before the carcasses can enter the scalding tank, and the potential for meat adulteration with fecal residues and blood. It is important to note that the proposed halal CP program is presented as a starting point for any individual halal certifying body to improve its practices. © 2016 Poultry Science Association Inc.

  19. A Study of a Two Stage Maximum Power Point Tracking Control of a Photovoltaic System under Partially Shaded Insolation Conditions

    Science.gov (United States)

    Kobayashi, Kenji; Takano, Ichiro; Sawada, Yoshio

    A photovoltaic array shows relatively low output power density, and has a greatly drooping Current-Voltage (I-V) characteristic. Therefore, Maximum Power Point Tracking (MPPT) control is used to maximize the output power of the array. Many papers have been reported in relation to MPPT. However, the Current-Power (I-P) curve sometimes shows multi-local maximum points mode under non-uniform insolation conditions. The operating point of the PV system tends to converge to a local maximum output point which is not the real maximal output point on the I-P curve. Some papers have been also reported, trying to avoid this difficulty. However most of those control systems become rather complicated. Then, the two stage MPPT control method is proposed in this paper to realize a relatively simple control system which can track the real maximum power point even under non-uniform insolation conditions. The feasibility of this control concept is confirmed for steady insolation as well as for rapidly changing insolation by simulation study using software PSIM and LabVIEW. In addition, simulated experiment confirms fundament al operation of the two stage MPPT control.

  20. A study of a two stage maximum power point tracking control of a photovoltaic system under partially shaded insolation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Kenji; Takano, Ichiro; Sawada, Yoshio [Kogakuin University, Tokyo 163-8677 (Japan)

    2006-11-23

    A photovoltaic (PV) array shows relatively low output power density, and has a greatly drooping current-voltage (I-V) characteristic. Therefore, maximum power point tracking (MPPT) control is used to maximize the output power of the PV array. Many papers have been reported in relation to MPPT. However, the current-power (I-P) curve sometimes shows multi-local maximum point mode under non-uniform insolation conditions. The operating point of the PV system tends to converge to a local maximum output point which is not the real maximal output point on the I-P curve. Some papers have been also reported, trying to avoid this difficulty. However, most of those control systems become rather complicated. Then, the two stage MPPT control method is proposed in this paper to realize a relatively simple control system which can track the real maximum power point even under non-uniform insolation conditions. The feasibility of this control concept is confirmed for steady insolation as well as for rapidly changing insolation by simulation study using software PSIM and LabVIEW. (author)

  1. End-Point Contact Force Control with Quantitative Feedback Theory for Mobile Robots

    Directory of Open Access Journals (Sweden)

    Shuhuan Wen

    2012-12-01

    Full Text Available Robot force control is an important issue for intelligent mobile robotics. The end-point stiffness of a robot is a key and open problem in the research community. The control strategies are mostly dependent on both the specifications of the task and the environment of the robot. Due to the limited stiffness of the end-effector, we may adopt inherent torque to feedback the oscillations of the controlled force. This paper proposes an effective control strategy which contains a controller using quantitative feedback theory. The nested loop controllers take into account the physical limitation of the system's inner variables and harmful interference. The biggest advantage of the method is its simplicity in both the design process and the implementation of the control algorithm in engineering practice. Taking the one-link manipulator as an example, numerical experiments are carried out to verify the proposed control method. The results show the satisfactory performance.

  2. Two-phase strategy of neural control for planar reaching movements: I. XY coordination variability and its relation to end-point variability.

    Science.gov (United States)

    Rand, Miya K; Shimansky, Yury P

    2013-03-01

    A quantitative model of optimal transport-aperture coordination (TAC) during reach-to-grasp movements has been developed in our previous studies. The utilization of that model for data analysis allowed, for the first time, to examine the phase dependence of the precision demand specified by the CNS for neurocomputational information processing during an ongoing movement. It was shown that the CNS utilizes a two-phase strategy for movement control. That strategy consists of reducing the precision demand for neural computations during the initial phase, which decreases the cost of information processing at the expense of lower extent of control optimality. To successfully grasp the target object, the CNS increases precision demand during the final phase, resulting in higher extent of control optimality. In the present study, we generalized the model of optimal TAC to a model of optimal coordination between X and Y components of point-to-point planar movements (XYC). We investigated whether the CNS uses the two-phase control strategy for controlling those movements, and how the strategy parameters depend on the prescribed movement speed, movement amplitude and the size of the target area. The results indeed revealed a substantial similarity between the CNS's regulation of TAC and XYC. First, the variability of XYC within individual trials was minimal, meaning that execution noise during the movement was insignificant. Second, the inter-trial variability of XYC was considerable during the majority of the movement time, meaning that the precision demand for information processing was lowered, which is characteristic for the initial phase. That variability significantly decreased, indicating higher extent of control optimality, during the shorter final movement phase. The final phase was the longest (shortest) under the most (least) challenging combination of speed and accuracy requirements, fully consistent with the concept of the two-phase control strategy. This paper

  3. The efficacy of agomelatine in elderly patients with recurrent major depressive disorder: a placebo-controlled study.

    Science.gov (United States)

    Heun, Reinhard; Ahokas, Antti; Boyer, Patrice; Giménez-Montesinos, Natalia; Pontes-Soares, Fernando; Olivier, Valérie

    2013-06-01

    The present placebo-controlled study evaluated the efficacy, tolerability, and safety of 8-week treatment with agomelatine (25-50 mg/d by mouth) in elderly patients with major depressive disorder (MDD). Elderly outpatients aged ≥ 65 years with a primary diagnosis of moderate to severe episode of recurrent MDD (DSM-IV-TR) were recruited in 27 clinical centers in Argentina, Finland, Mexico, Portugal, and Romania from November 2009 to October 2011. The primary outcome measure was the 17-item Hamilton Depression Rating Scale (HDRS17) total score. A total of 222 elderly patients entered the study (151 in the agomelatine group, 71 in the placebo group), including 69 patients aged 75 years and older. Agomelatine improved depressive symptoms in the elderly population, as evaluated by the HDRS17 total score, in terms of last postbaseline value (agomelatine-placebo difference: mean estimate [standard error] = 2.67 [1.06] points; P = .013) and response to treatment (agomelatine, 59.5%; placebo, 38.6%; P = .004). The agomelatine-placebo difference according to the Clinical Global Impressions-Severity of Illness scale (CGI-S) score was 0.48 (0.19). The agomelatine-placebo difference (estimate [standard error]) for remission on the HDRS17 was 6.9% (4.7%) and did not achieve statistical significance (P = .179, post hoc analysis). Clinically relevant effects of agomelatine were confirmed on all end points in the subset of severely depressed patients (HDRS17 total score ≥ 25 and CGI-S score ≥ 5 at baseline). Agomelatine was well tolerated by patients, with only minimal distinctions from placebo. The present study provides the first evidence that an 8-week treatment with agomelatine 25-50 mg/d efficiently relieves depressive symptoms and is well tolerated in elderly depressed patients older than 65 years. Controlled-Trials.com identifier: ISRCTN57507360. © Copyright 2011 Physicians Postgraduate Press, Inc.

  4. LIFE CYCLE ASSESSMENT AND HAZARD ANALYSIS AND CRITICAL CONTROL POINTS TO THE PASTA PRODUCT

    Directory of Open Access Journals (Sweden)

    Yulexis Meneses Linares

    2016-10-01

    Full Text Available The objective of this work is to combine the Life Cycle Assessment (LCA and Hazard Analysis and Critical Control Points (HACCP methodologies for the determination of risks that the food production represents to the human health and the ecosystem. The environmental performance of the production of pastas in the “Marta Abreu” Pasta Factory of Cienfuegos is assessed, where the critical control points determined by the biological dangers (mushrooms and plagues and the physical dangers (wood, paper, thread and ferromagnetic particles were the raw materials: flour, semolina and its mixtures, and the disposition and extraction of them. Resources are the most affected damage category due to the consumption of fossil fuels.

  5. Gradient-free determination of isoelectric points of proteins on chip.

    Science.gov (United States)

    Łapińska, Urszula; Saar, Kadi L; Yates, Emma V; Herling, Therese W; Müller, Thomas; Challa, Pavan K; Dobson, Christopher M; Knowles, Tuomas P J

    2017-08-30

    The isoelectric point (pI) of a protein is a key characteristic that influences its overall electrostatic behaviour. The majority of conventional methods for the determination of the isoelectric point of a molecule rely on the use of spatial gradients in pH, although significant practical challenges are associated with such techniques, notably the difficulty in generating a stable and well controlled pH gradient. Here, we introduce a gradient-free approach, exploiting a microfluidic platform which allows us to perform rapid pH change on chip and probe the electrophoretic mobility of species in a controlled field. In particular, in this approach, the pH of the electrolyte solution is modulated in time rather than in space, as in the case for conventional determinations of the isoelectric point. To demonstrate the general approachability of this platform, we have measured the isoelectric points of representative set of seven proteins, bovine serum albumin, β-lactoglobulin, ribonuclease A, ovalbumin, human transferrin, ubiquitin and myoglobin in microlitre sample volumes. The ability to conduct measurements in free solution thus provides the basis for the rapid determination of isoelectric points of proteins under a wide variety of solution conditions and in small volumes.

  6. Evaluation of a proper controller performance for maximum-power point tracking of a stand-alone PV system

    Energy Technology Data Exchange (ETDEWEB)

    Nafeh, A.E.-S.A.; Fahmy, F.H. [Electronics Research Institute, Cairo (Egypt); El-Zahab, E.M.A. [Cairo University, Giza (Egypt). Faculty of Engineering

    2003-02-01

    In this paper the implementation of a suggested stand-alone PV system, for maximum-power point tracking (MPPT), is carried out. Also, this paper presents a comparative study, through experimental work, between the conventional PI controller and the fuzzy logic controller (FLC) under different atmospheric conditions. The implemented system with both the PI controller and the FLC gives a good maximum-power operation of the PV array, but the tracking capability for different optimum operating points is better and faster for the case of using the FLC compared to the case of using the PI controller. (author)

  7. [Powdered infant formulae preparation guide for hospitals based on Hazard Analysis and Critical Control Points (HACCP) principles].

    Science.gov (United States)

    Vargas-Leguás, H; Rodríguez Garrido, V; Lorite Cuenca, R; Pérez-Portabella, C; Redecillas Ferreiro, S; Campins Martí, M

    2009-06-01

    This guide for the preparation of powdered infant formulae in hospital environments is a collaborative work between several hospital services and is based on national and European regulations, international experts meetings and the recommendations of scientific societies. This guide also uses the Hazard Analysis and Critical Control Point principles proposed by Codex Alimentarius and emphasises effective verifying measures, microbiological controls of the process and the corrective actions when monitoring indicates that a critical control point is not under control. It is a dynamic guide and specifies the evaluation procedures that allow it to be constantly adapted.

  8. Optimality with feedback control in relativistic dynamics of a mass point. Part 1

    International Nuclear Information System (INIS)

    Blaquiere, A.; Pauchard, M.; Tahri-Yousfi, N.; Wickers, D.

    1984-01-01

    This article is an account of part of a research task currently in progress; it deals with relativistic dynamics of a mass-point from the point of view of the theory of optimal feedback control. In the first part, the theoretical frame is presented with an application to the case of special Relativity. This application shows that the way followed in this article is a natural one for approaching Wave mechanics, and that it closely parallels the way along which Louis de Broglie introduced Wave mechanics [fr

  9. The equilibrium-point hypothesis--past, present and future.

    Science.gov (United States)

    Feldman, Anatol G; Levin, Mindy F

    2009-01-01

    This chapter is a brief account of fundamentals of the equilibrium-point hypothesis or more adequately called the threshold control theory (TCT). It also compares the TCT with other approaches to motor control. The basic notions of the TCT are reviewed with a major focus on solutions to the problems of multi-muscle and multi-degrees of freedom redundancy. The TCT incorporates cognitive aspects by explaining how neurons recognize that internal (neural) and external (environmental) events match each other. These aspects as well as how motor learning occurs are subjects of further development of the TCT hypothesis.

  10. A randomized controlled comparison of electroconvulsive therapy and repetitive transcranial magnetic stimulation in severe and resistant nonpsychotic major depression.

    Science.gov (United States)

    Grunhaus, Leon; Schreiber, Shaul; Dolberg, Ornah T; Polak, Dana; Dannon, Pinhas N

    2003-02-15

    Studies published over the past few years suggest that transcranial magnetic stimulation (TMS) may have significant antidepressant actions. In a previous report, we compared electroconvulsive therapy (ECT) and repetitive TMS (rTMS) and found ECT to be superior for psychotic major depression (MD); however, ECT and rTMS had similar results in nonpsychotic MD. We now report on a controlled randomized comparison of ECT and rTMS in patients with nonpsychotic MD. Forty patients with nonpsychotic MD referred for ECT were included. Electroconvulsive therapy was performed according to established protocols. Repetitive TMS was performed over the left dorsolateral prefrontal cortex at 90% motor threshold. Patients were treated with 20 sessions (five times per week for 4 weeks) of 10-Hz treatments (1200 pulses per treatment-day) at 90% motor threshold. Response to treatment was defined as a decrease of at least 50% in the Hamilton Rating Scale for Depression (HRSD) score, with a final HRSD equal or less than 10 points and a final Global Assessment of Function Scale rating of 60 or more points. The overall response rate was 58% (23 out of 40 patients responded to treatment). In the ECT group, 12 responded and eight did not; in the rTMS group, 11 responded and nine did not (chi2 =.10, ns). Thus, patients responded as well to either ECT or rTMS. This study adds to the growing literature supporting an antidepressant effect for rTMS. This study is particularly relevant because it suggests that rTMS and ECT reach similar results in nonpsychotic major depressive disorder.

  11. Report on the Audit of Internal Controls Over DoD Major Suggestion Awards

    Science.gov (United States)

    1992-01-22

    This final report on the Audit of Major Suggestion Awards is provided for your information and use. The audit was requested by the Assistant...suggestions. If adopted, the revision could substantially increase the number of cases with awards over $10,000. The audit was made from September through...October 1991. The overall objective of the audit was to determine whether existing internal controls ensured the integrity of major suggestion awards

  12. Observer-based design of set-point tracking adaptive controllers for nonlinear chaotic systems

    International Nuclear Information System (INIS)

    Khaki-Sedigh, A.; Yazdanpanah-Goharrizi, A.

    2006-01-01

    A gradient based approach for the design of set-point tracking adaptive controllers for nonlinear chaotic systems is presented. In this approach, Lyapunov exponents are used to select the controller gain. In the case of unknown or time varying chaotic plants, the Lyapunov exponents may vary during the plant operation. In this paper, an effective adaptive strategy is used for online identification of Lyapunov exponents and adaptive control of nonlinear chaotic plants. Also, a nonlinear observer for estimation of the states is proposed. Simulation results are provided to show the effectiveness of the proposed methodology

  13. Observer-based design of set-point tracking adaptive controllers for nonlinear chaotic systems

    Energy Technology Data Exchange (ETDEWEB)

    Khaki-Sedigh, A. [Department of Electrical Engineering, K.N. Toosi University of Technology, Sayyed Khandan Bridge, Shariati Street, Tehran 16314 (Iran, Islamic Republic of)]. E-mail: sedigh@kntu.ac.ir; Yazdanpanah-Goharrizi, A. [Department of Electrical Engineering, K.N. Toosi University of Technology, Sayyed Khandan Bridge, Shariati Street, Tehran 16314 (Iran, Islamic Republic of)]. E-mail: yazdanpanah@ee.kntu.ac.ir

    2006-09-15

    A gradient based approach for the design of set-point tracking adaptive controllers for nonlinear chaotic systems is presented. In this approach, Lyapunov exponents are used to select the controller gain. In the case of unknown or time varying chaotic plants, the Lyapunov exponents may vary during the plant operation. In this paper, an effective adaptive strategy is used for online identification of Lyapunov exponents and adaptive control of nonlinear chaotic plants. Also, a nonlinear observer for estimation of the states is proposed. Simulation results are provided to show the effectiveness of the proposed methodology.

  14. A measured-ZMP(Zero-Moment-Point)-referenced control of biped locomotion robots

    International Nuclear Information System (INIS)

    Kume, Etsuo; Akimoto, Masayuki

    1994-01-01

    For the control of biped locomotion, the model-referenced-control or programmed control method is widely used. In this method, the instantaneous torque of actuator equipped at each joint is controlled so as to equalize measured angle to input joint angle based on the prescribed motion. The drawback is that this method can not deal with the dynamic change of walking such as that due to unknown external force. To resolve such the drawback, we propose a new control method as follows: given a prescribed motion as a set of gait, namely gait of starting walk, cyclic walk, and stopping walk including a standard trajectory of the Zero-Moment-Point (ZMP), the trunk motion to compensate the legs' motion is generated in real time using the current ZMP measured by sensing device. The proposed method will be validated through some numerical simulations. (author)

  15. L1 Adaptive Speed Control of a Small Wind Energy Conversion System for Maximum Power Point Tracking

    DEFF Research Database (Denmark)

    Zhao, Haoran; Wu, Qiuwei; Rasmussen, Claus Nygaard

    2014-01-01

    This paper presents the design of an L1 adaptive controller for maximum power point tracking (MPPT) of a small variable speed Wind Energy Conversion System (WECS). The proposed controller generates the optimal torque command for the vector controlled generator side converter (GSC) based on the wi......) is used to carry out case studies using Matlab/Simulink. The case study results show that the designed L1 adaptive controller has good tracking performance even with unmodeled dynamics and in the presence of parameter uncertainties and unknown disturbances.......This paper presents the design of an L1 adaptive controller for maximum power point tracking (MPPT) of a small variable speed Wind Energy Conversion System (WECS). The proposed controller generates the optimal torque command for the vector controlled generator side converter (GSC) based on the wind...

  16. Digitally Controlled Point of Load Converter with Very Fast Transient Response

    DEFF Research Database (Denmark)

    Jakobsen, Lars Tønnes; Andersen, Michael Andreas E.

    2007-01-01

    voltage mode control and very fast transient response. The DiSOM modulator is combined with a digital PID compensator algorithm is implemented in a hybrid CPLD/FPGA and is used to control a synchronous Buck converter, which is used in typical Point of Load applications. The computational time is only......This paper presents a new Digital Self-Oscillating Modulator (DiSOM) that allows the duty cycle to be changed instantly. The DiSOM modulator is shown to have variable switching that is a function of the duty cycle. Compared to a more traditional digital PWM modulator based on a counter...... and comparator the DiSOM modulator allows the sampling frequency of the output voltage control loop to be higher than the switching frequency of the power converter, typically a DC/DC converter. The features of the DiSOM modulator makes it possible to design a digitally controlled DC/DC converter with linear...

  17. Major parasitic diseases of poverty in mainland China: perspectives for better control.

    Science.gov (United States)

    Wang, Jin-Lei; Li, Ting-Ting; Huang, Si-Yang; Cong, Wei; Zhu, Xing-Quan

    2016-08-01

    Significant progress has been made in the prevention, control, and elimination of human parasitic diseases in China in the past 60 years. However, parasitic diseases of poverty remain major causes of morbidity and mortality, and inflict enormous economic costs on societies.In this article, we review the prevalence rates, geographical distributions, epidemic characteristics, risk factors, and clinical manifestations of parasitic diseases of poverty listed in the first issue of the journal Infectious Diseases of Poverty on 25 October 2012. We also address the challenges facing control of parasitic diseases of poverty and provide suggestions for better control.

  18. Augmented Nonlinear Controller for Maximum Power-Point Tracking with Artificial Neural Network in Grid-Connected Photovoltaic Systems

    Directory of Open Access Journals (Sweden)

    Suliang Ma

    2016-11-01

    Full Text Available Photovoltaic (PV systems have non-linear characteristics that generate maximum power at one particular operating point. Environmental factors such as irradiance and temperature variations greatly affect the maximum power point (MPP. Diverse offline and online techniques have been introduced for tracking the MPP. Here, to track the MPP, an augmented-state feedback linearized (AFL non-linear controller combined with an artificial neural network (ANN is proposed. This approach linearizes the non-linear characteristics in PV systems and DC/DC converters, for tracking and optimizing the PV system operation. It also reduces the dependency of the designed controller on linearized models, to provide global stability. A complete model of the PV system is simulated. The existing maximum power-point tracking (MPPT and DC/DC boost-converter controller techniques are compared with the proposed ANN method. Two case studies, which simulate realistic circumstances, are presented to demonstrate the effectiveness and superiority of the proposed method. The AFL with ANN controller can provide good dynamic operation, faster convergence speed, and fewer operating-point oscillations around the MPP. It also tracks the global maxima under different conditions, especially irradiance-mutating situations, more effectively than the conventional methods. Detailed mathematical models and a control approach for a three-phase grid-connected intelligent hybrid system are proposed using MATLAB/Simulink.

  19. Control of cutaneous leishmaniasis caused by Leishmania major in south-eastern Morocco.

    Science.gov (United States)

    Bennis, Issam; De Brouwere, Vincent; Ameur, Btissam; El Idrissi Laamrani, Abderrahmane; Chichaoui, Smaine; Hamid, Sahibi; Boelaert, Marleen

    2015-10-01

    The incidence of cutaneous leishmaniasis (CL) caused by Leishmania major has increased in Morocco over the last decade, prompting the Ministry of Health to take intersectoral response measures including vector and reservoir control. The aim of this article was to describe the CL outbreak response measures taken in the province of Errachidia, where the reservoir of L. major, a sand rat (Meriones shawi), was targeted using strychnine-poisoned wheat baits from 2010 to 2012. We analysed routine surveillance data and other information using the data of the CL control programme. We present data on the evolution and the extension of CL in this province as well as the epidemiological profile of the disease. Between 2004 and 2013, 7099 cases of CL were recorded in Errachidia Province, gradually affecting all districts. Our results demonstrate that more women were affected than men and that all age groups were represented. Errachidia Province was the epicentre of the recent CL outbreak in Morocco. A notable decline in incidence rates was observed after 2011. The outbreak control measures may have contributed to this decline, as well as climatic trends or progressing herd immunity. © 2015 John Wiley & Sons Ltd.

  20. Waveguides with Absorbing Boundaries: Nonlinearity Controlled by an Exceptional Point and Solitons

    Science.gov (United States)

    Midya, Bikashkali; Konotop, Vladimir V.

    2017-07-01

    We reveal the existence of continuous families of guided single-mode solitons in planar waveguides with weakly nonlinear active core and absorbing boundaries. Stable propagation of TE and TM-polarized solitons is accompanied by attenuation of all other modes, i.e., the waveguide features properties of conservative and dissipative systems. If the linear spectrum of the waveguide possesses exceptional points, which occurs in the case of TM polarization, an originally focusing (defocusing) material nonlinearity may become effectively defocusing (focusing). This occurs due to the geometric phase of the carried eigenmode when the surface impedance encircles the exceptional point. In its turn, the change of the effective nonlinearity ensures the existence of dark (bright) solitons in spite of focusing (defocusing) Kerr nonlinearity of the core. The existence of an exceptional point can also result in anomalous enhancement of the effective nonlinearity. In terms of practical applications, the nonlinearity of the reported waveguide can be manipulated by controlling the properties of the absorbing cladding.

  1. Quality control for electron beam processing of polymeric materials by end-point analysis

    International Nuclear Information System (INIS)

    DeGraff, E.; McLaughlin, W.L.

    1981-01-01

    Properties of certain plastics, e.g. polytetrafluoroethylene, polyethylene, ethylene vinyl acetate copolymer, can be modified selectively by ionizing radiation. One of the advantages of this treatment over chemical methods is better control of the process and the end-product properties. The most convenient method of dosimetry for monitoring quality control is post-irradiation evaluation of the plastic itself, e.g., melt index and melt point determination. It is shown that by proper calibration in terms of total dose and sufficiently reproducible radiation effects, such product test methods provide convenient and meaningful analyses. Other appropriate standardized analytical methods include stress-crack resistance, stress-strain-to-fracture testing and solubility determination. Standard routine dosimetry over the dose and dose rate ranges of interest confirm that measured product end points can be correlated with calibrated values of absorbed dose in the product within uncertainty limits of the measurements. (author)

  2. Installation of PMV Operation Program in DDC Controller and Air Conditioning Control Using PMV Directly as Set Point

    Science.gov (United States)

    Haramoto, Ken-Ichi

    In general, air conditioning control in a building is operated mainly by indoor air temperature control. Although the operators of the machine in the building accepted a claim for indoor air temperature presented by the building inhabitants, the indoor conditions have been often too cool or warm. Therefore, in an attempt to create better thermal environments, the author paid attention to the PMV that is a thermal comfort index. And then, the possibility of air conditioning control using the PMV directly as the set point was verified by employing actual equipment in an air conditioning testing room and an office building. Prior to the execution of this control, the operation program of the PMV was installed in a DDC controller for the air conditioning control. And information from indoor sensors and so on was inputted to the controller, and the computed PMV was used as the feedback variable.

  3. Gulf of Maine - Control Points Used to Validate the Accuracies of the Interpolated Water Density Rasters

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This feature dataset contains the control points used to validate the accuracies of the interpolated water density rasters for the Gulf of Maine. These control...

  4. An X-point ergodic divertor

    International Nuclear Information System (INIS)

    Chu, M.S.; Jensen, T.H.; La Haye, R.J.; Taylor, T.S.; Evans, T.E.

    1991-10-01

    A new ergodic divertor is proposed. It utilizes a system of external (n = 3) coils arranged to generate overlapping magnetic islands in the edge region of a diverted tokamak and connect the randomized field lines to the external (cold) divertor plate. The novel feature in the configuration is the placement of the external coils close to the X-point. A realistic design of the external coil set is studied by using the field line tracing method for a low aspect ratio (A ≅ 3) tokamak. Two types of effects are observed. First, by placing the coils close to the X-point, where the poloidal magnetic field is weak and the rational surfaces are closely packed only a moderate amount of current in the external coils is needed to ergodize the edge region. This ergodized edge enhances the edge transport in the X-point region and leads to the potential of edge profile control and the avoidance of edge localized modes (ELMs). Furthermore, the trajectories of the field lines close to the X-point are modified by the external coil set, causing the hit points on the external divertor plates to be randomized and spread out in the major radius direction. A time-dependent modulation of the currents in the external (n = 3) coils can potentially spread the heat flux more uniformly on the divertor plate avoiding high concentration of the heat flux. 10 refs., 9 figs

  5. Pilot program: NRC severe reactor accident incident response training manual. Overview and summary of major points

    International Nuclear Information System (INIS)

    McKenna, T.J.; Martin, J.A. Jr.; Giitter, J.G.; Miller, C.W.; Hively, L.M.; Sharpe, R.W.; Watkins

    1987-02-01

    Overview and Summary of Major Points is the first in a series of volumes that collectively summarize the U.S. Nuclear Regulatory Commission (NRC) emergency response during severe power reactor accidents and provide necessary background information. This volume describes elementary perspectives on severe accidents and accident assessment. Other volumes in the series are: Volume 2-Severe Reactor Accident Overview; Volume 3- Response of Licensee and State and Local Officials; Volume 4-Public Protective Actions-Predetermined Criteria and Initial Actions; Volume 5 - U.S. Nuclear Regulatory Commission. Each volume serves, respectively, as the text for a course of instruction in a series of courses for NRC response personnel. These materials do not provide guidance or license requirements for NRC licensees. The volumes have been organized into these training modules to accommodate the scheduling and duty needs of participating NRC staff. Each volume is accompanied by an appendix of slides that can be used to present this material

  6. System implementation of hazard analysis and critical control points (HACCP) in a nitrogen production plant

    International Nuclear Information System (INIS)

    Barrantes Salazar, Alexandra

    2014-01-01

    System of hazard analysis and critical control points are deployed in a production plant of liquid nitrogen. The fact that the nitrogen has become a complement to food packaging to increase shelf life, or provide a surface that protect it from manipulation, has been the main objective. Analysis of critical control points for the nitrogen production plant has been the adapted methodology. The knowledge of both the standard and the production process, as well as the on site verification process, have been necessary. In addition, all materials and/or processing units that are found in contact with the raw material or the product under study were evaluated. Such a way that the intrinsic risks of each were detected, from the physical, chemical and biological points of view according to the origin or pollution source. For each found risk was evaluated the probability of occurrence according to the frequency and gravity of it, with these variables determined was achieved the definition of the type of risk detected. In the cases that was presented a greater risk or critical, these were subjected decision tree; with which is concluded the non determination of critical control points. However, for each one of them were established the maximum permitted limits. To generate each of the results it has literature or scientific reference of reliable provenance, where is indicated properly the support of the evaluated matter. In a general way, the material matrix and the process matrix are found without critical control points; so that the project is concluded in the analysis, and it has to generate without the monitoring system and verification. To increase this project is suggested in order to cover the packaging system of gaseous nitrogen, due to it was delimited to liquid nitrogen. Furthermore, the liquid nitrogen is a 100% automated and closed process so the introduction of contaminants is very reduced, unlike the gaseous nitrogen process. (author) [es

  7. On Motion Planning for Point-to-Point Maneuvers for a Class of Sailing Vehicles

    DEFF Research Database (Denmark)

    Xiao, Lin; Jouffroy, Jerome

    2011-01-01

    Despite their interesting dynamic and controllability properties, sailing vehicles have not been much studied in the control community. In this paper, we investigate motion planning of such vehicles. Starting from a simple dynamic model of sailing vessels in one dimension, this paper first...... considers their associated controllability issues, with the so-called no-sailing zone as a starting point, and it links them with a motion planning strategy using two-point boundary value problems as the main mathematical tool. This perspective is then expanded to do point-to-point maneuvers of sailing...

  8. Once more on the equilibrium-point hypothesis (lambda model) for motor control.

    Science.gov (United States)

    Feldman, A G

    1986-03-01

    The equilibrium control hypothesis (lambda model) is considered with special reference to the following concepts: (a) the length-force invariant characteristic (IC) of the muscle together with central and reflex systems subserving its activity; (b) the tonic stretch reflex threshold (lambda) as an independent measure of central commands descending to alpha and gamma motoneurons; (c) the equilibrium point, defined in terms of lambda, IC and static load characteristics, which is associated with the notion that posture and movement are controlled by a single mechanism; and (d) the muscle activation area (a reformulation of the "size principle")--the area of kinematic and command variables in which a rank-ordered recruitment of motor units takes place. The model is used for the interpretation of various motor phenomena, particularly electromyographic patterns. The stretch reflex in the lambda model has no mechanism to follow-up a certain muscle length prescribed by central commands. Rather, its task is to bring the system to an equilibrium, load-dependent position. Another currently popular version defines the equilibrium point concept in terms of alpha motoneuron activity alone (the alpha model). Although the model imitates (as does the lambda model) spring-like properties of motor performance, it nevertheless is inconsistent with a substantial data base on intact motor control. An analysis of alpha models, including their treatment of motor performance in deafferented animals, reveals that they suffer from grave shortcomings. It is concluded that parameterization of the stretch reflex is a basis for intact motor control. Muscle deafferentation impairs this graceful mechanism though it does not remove the possibility of movement.

  9. SU-E-T-72: A Retrospective Correlation Analysis On Dose-Volume Control Points and Treatment Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Roy, A; Nohadani, O [Northwestern University, Evanston, IL (United States); Refaat, T; Bacchus, I; Cutright, D; Sathiaseelan, V; Mittal, B [Northwestern University, Chicago, IL (United States)

    2015-06-15

    Purpose: To quantify correlation between dose-volume control points and treatment outcomes. Specifically, two outcomes are analyzed: occurrence of radiation induced dysphagia and target complications. The results inform the treatment planning process when competing dose-volume criteria requires relaxations. Methods: 32 patients, treated with whole-field sequential intensity modulated radiation therapy during 2009–2010 period, are considered for this study. Acute dysphagia that is categorized into 3 grades is observed on all patients. 3 patients are observed in grade 1, 17 patients in grade 2, and 12 patients in grade 3. Ordinal logistic regression is employed to establish correlations between grades of dysphagia and dose to cervico-thoracic esophagus. Particularly, minimum (Dmin), mean (Dmean), and maximum (Dmax) dose control points are analyzed. Additionally, target complication, which includes local-regional recurrence and/or distant metastasis, is observed on 4 patients. Binary logistic regression is used to quantify correlation between target complication and four dose control points. Namely, ICRU recommended dose control points, D2, D50, D95, and D98 are analyzed. Results: For correlation with dysphagia, Dmin on cervico-thoracic esophagus is statistically significant (p-value = 0.005). Additionally, Dmean on cervico-thoracic esophagus is also significant in association with dysphagia (p-value = 0.012). However, no correlation was observed between Dmax and dysphagia (p-value = 0.263). For target complications, D50 on the target is a statistically significant dose control point (p-value = 0.032). No correlations were observed between treatment complications and D2 (p-value = 0.866), D95 (p-value = 0.750), and D98 (p-value = 0.710) on the target. Conclusion: Significant correlations are observed between radiation induced dysphagia and Dmean (and Dmin) to cervico-thoracic esophagus. Additionally, correlation between target complications and median dose to target

  10. SU-E-T-72: A Retrospective Correlation Analysis On Dose-Volume Control Points and Treatment Outcomes

    International Nuclear Information System (INIS)

    Roy, A; Nohadani, O; Refaat, T; Bacchus, I; Cutright, D; Sathiaseelan, V; Mittal, B

    2015-01-01

    Purpose: To quantify correlation between dose-volume control points and treatment outcomes. Specifically, two outcomes are analyzed: occurrence of radiation induced dysphagia and target complications. The results inform the treatment planning process when competing dose-volume criteria requires relaxations. Methods: 32 patients, treated with whole-field sequential intensity modulated radiation therapy during 2009–2010 period, are considered for this study. Acute dysphagia that is categorized into 3 grades is observed on all patients. 3 patients are observed in grade 1, 17 patients in grade 2, and 12 patients in grade 3. Ordinal logistic regression is employed to establish correlations between grades of dysphagia and dose to cervico-thoracic esophagus. Particularly, minimum (Dmin), mean (Dmean), and maximum (Dmax) dose control points are analyzed. Additionally, target complication, which includes local-regional recurrence and/or distant metastasis, is observed on 4 patients. Binary logistic regression is used to quantify correlation between target complication and four dose control points. Namely, ICRU recommended dose control points, D2, D50, D95, and D98 are analyzed. Results: For correlation with dysphagia, Dmin on cervico-thoracic esophagus is statistically significant (p-value = 0.005). Additionally, Dmean on cervico-thoracic esophagus is also significant in association with dysphagia (p-value = 0.012). However, no correlation was observed between Dmax and dysphagia (p-value = 0.263). For target complications, D50 on the target is a statistically significant dose control point (p-value = 0.032). No correlations were observed between treatment complications and D2 (p-value = 0.866), D95 (p-value = 0.750), and D98 (p-value = 0.710) on the target. Conclusion: Significant correlations are observed between radiation induced dysphagia and Dmean (and Dmin) to cervico-thoracic esophagus. Additionally, correlation between target complications and median dose to target

  11. Efficiency of Photovoltaic Maximum Power Point Tracking Controller Based on a Fuzzy Logic

    Directory of Open Access Journals (Sweden)

    Ammar Al-Gizi

    2017-07-01

    Full Text Available This paper examines the efficiency of a fuzzy logic control (FLC based maximum power point tracking (MPPT of a photovoltaic (PV system under variable climate conditions and connected load requirements. The PV system including a PV module BP SX150S, buck-boost DC-DC converter, MPPT, and a resistive load is modeled and simulated using Matlab/Simulink package. In order to compare the performance of FLC-based MPPT controller with the conventional perturb and observe (P&O method at different irradiation (G, temperature (T and connected load (RL variations – rising time (tr, recovering time, total average power and MPPT efficiency topics are calculated. The simulation results show that the FLC-based MPPT method can quickly track the maximum power point (MPP of the PV module at the transient state and effectively eliminates the power oscillation around the MPP of the PV module at steady state, hence more average power can be extracted, in comparison with the conventional P&O method.

  12. Tunable superlattice in graphene to control the number of Dirac points.

    Science.gov (United States)

    Dubey, Sudipta; Singh, Vibhor; Bhat, Ajay K; Parikh, Pritesh; Grover, Sameer; Sensarma, Rajdeep; Tripathi, Vikram; Sengupta, K; Deshmukh, Mandar M

    2013-09-11

    Superlattice in graphene generates extra Dirac points in the band structure and their number depends on the superlattice potential strength. Here, we have created a lateral superlattice in a graphene device with a tunable barrier height using a combination of two gates. In this Letter, we demonstrate the use of lateral superlattice to modify the band structure of graphene leading to the emergence of new Dirac cones. This controlled modification of the band structure persists up to 100 K.

  13. [Introduction of hazard analysis and critical control points (HACCP) principles at the flight catering food production plant].

    Science.gov (United States)

    Popova, A Yu; Trukhina, G M; Mikailova, O M

    In the article there is considered the quality control and safety system implemented in the one of the largest flight catering food production plant for airline passengers and flying squad. The system for the control was based on the Hazard Analysis And Critical Control Points (HACCP) principles and developed hygienic and antiepidemic measures. There is considered the identification of hazard factors at stages of the technical process. There are presented results of the analysis data of monitoring for 6 critical control points over the five-year period. The quality control and safety system permit to decline food contamination risk during acceptance, preparation and supplying of in-flight meal. There was proved the efficiency of the implemented system. There are determined further ways of harmonization and implementation for HACCP principles in the plant.

  14. Optimized Latching Control of Floating Point Absorber Wave Energy Converter

    Science.gov (United States)

    Gadodia, Chaitanya; Shandilya, Shubham; Bansal, Hari Om

    2018-03-01

    There is an increasing demand for energy in today’s world. Currently main energy resources are fossil fuels, which will eventually drain out, also the emissions produced from them contribute to global warming. For a sustainable future, these fossil fuels should be replaced with renewable and green energy sources. Sea waves are a gigantic and undiscovered vitality asset. The potential for extricating energy from waves is extensive. To trap this energy, wave energy converters (WEC) are needed. There is a need for increasing the energy output and decreasing the cost requirement of these existing WECs. This paper presents a method which uses prediction as a part of the control scheme to increase the energy efficiency of the floating-point absorber WECs. Kalman Filter is used for estimation, coupled with latching control in regular as well as irregular sea waves. Modelling and Simulation results for the same are also included.

  15. Major and Trace Element Fluxes to the Ganges River: Significance of Small Flood Plain Tributary as Non-Point Pollution Source

    Science.gov (United States)

    Lakshmi, V.; Sen, I. S.; Mishra, G.

    2017-12-01

    There has been much discussion amongst biologists, ecologists, chemists, geologists, environmental firms, and science policy makers about the impact of human activities on river health. As a result, multiple river restoration projects are on going on many large river basins around the world. In the Indian subcontinent, the Ganges River is the focal point of all restoration actions as it provides food and water security to half a billion people. Serious concerns have been raised about the quality of Ganga water as toxic chemicals and many more enters the river system through point-sources such as direct wastewater discharge to rivers, or non-point-sources. Point source pollution can be easily identified and remedial actions can be taken; however, non-point pollution sources are harder to quantify and mitigate. A large non-point pollution source in the Indo-Gangetic floodplain is the network of small floodplain rivers. However, these rivers are rarely studied since they are small in catchment area ( 1000-10,000 km2) and discharge (knowledge gap we have monitored the Pandu River for one year between February 2015 and April 2016. Pandu river is 242 km long and is a right bank tributary of Ganges with a total catchment area of 1495 km2. Water samples were collected every month for dissolved major and trace elements. Here we show that the concentration of heavy metals in river Pandu is in higher range as compared to the world river average, and all the dissolved elements shows a large spatial-temporal variation. We show that the Pandu river exports 192170, 168517, 57802, 32769, 29663, 1043, 279, 241, 225, 162, 97, 28, 25, 22, 20, 8, 4 Kg/yr of Ca, Na, Mg, K, Si, Sr, Zn, B, Ba, Mn, Al, Li, Rb, Mo, U, Cu, and Sb, respectively, to the Ganga river, and the exported chemical flux effects the water chemistry of the Ganga river downstream of its confluence point. We further speculate that small floodplain rivers is an important source that contributes to the dissolved chemical

  16. Post-operative endophthalmitis: the application of hazard analysis critical control points (HACCP) to an infection control problem.

    Science.gov (United States)

    Baird, D R; Henry, M; Liddell, K G; Mitchell, C M; Sneddon, J G

    2001-09-01

    Hazard analysis critical control points (HACCP) is a quality assurance system widely used in the food industry to ensure safety. We adopted the HACCP approach when conventional infection control measures had failed to solve an ongoing problem with an increased incidence of postoperative endophthalmitis, and our ophthalmology unit was threatened with permanent cessation of intraocular surgery. Although time-consuming, the result was an entirely new set of protocols for the care of patients undergoing intraocular surgery, the development of an integrated care pathway, and a comprehensive and robust audit programme, which enabled intraocular surgery to continue in a new spirit of confidence. HACCP methodology has so far been little used in healthcare, but it might be usefully applied to a variety of apparently intractable infection control problems. Copyright 2001 The Hospital Infection Society.

  17. Perceived Intensity of Emotional Point-Light Displays Is Reduced in Subjects with ASD

    Science.gov (United States)

    Krüger, Britta; Kaletsch, Morten; Pilgramm, Sebastian; Schwippert, Sven-Sören; Hennig, Jürgen; Stark, Rudolf; Lis, Stefanie; Gallhofer, Bernd; Sammer, Gebhard; Zentgraf, Karen; Munzert, Jörn

    2018-01-01

    One major characteristic of autism spectrum disorder (ASD) is problems with social interaction and communication. The present study explored ASD-related alterations in perceiving emotions expressed via body movements. 16 participants with ASD and 16 healthy controls observed video scenes of human interactions conveyed by point-light displays. They…

  18. Evaluation of a spirituality informed e-mental health tool as an intervention for major depressive disorder in adolescents and young adults - a randomized controlled pilot trial.

    Science.gov (United States)

    Rickhi, Badri; Kania-Richmond, Ania; Moritz, Sabine; Cohen, Jordan; Paccagnan, Patricia; Dennis, Charlotte; Liu, Mingfu; Malhotra, Sonya; Steele, Patricia; Toews, John

    2015-12-24

    Depression in adolescents and young adults is a major mental health condition that requires attention. Research suggests that approaches that include spiritual concepts and are delivered through an online platform are a potentially beneficial approach to treating/managing depression in this population. The purpose of this study was to evaluate the effectiveness of an 8-week online spirituality informed e-mental health intervention (the LEAP Project) on depression severity, and secondary outcomes of spiritual well-being and self-concept, in adolescents and young adults with major depressive disorder of mild to moderate severity. A parallel group, randomized, waitlist controlled, assessor-blinded clinical pilot trial was conducted in Calgary, Alberta, Canada. The sample of 62 participants with major depressive disorder (DSM-IV-TR) was defined by two age subgroups: adolescents (ages 13 to 18 years; n = 31) and young adults (ages 19 to 24 years; n = 31). Participants in each age subgroup were randomized into the study arm (intervention initiated upon enrolment) or the waitlist control arm (intervention initiated after an 8-week wait period). Comparisons were made between the study and waitlist control arms at week 8 (the point where study arm had completed the intervention and the waitlist control arm had not) and within each arm at four time points over 24-week follow-up period. At baseline, there was no statistical difference between study and waitlist participants for both age subgroups for all three outcomes of interest. After the intervention, depression severity was significantly reduced; comparison across arms at week 8 and over time within each arm and both age subgroups. Spiritual well-being changes were not significant, with the exception of an improvement over time for the younger participants in the study arm (p = 0.01 at week 16 and p = 0.0305 at week 24). Self-concept improved significantly for younger participants immediately after the

  19. Stabilizing unstable fixed points of chaotic maps via minimum entropy control

    Energy Technology Data Exchange (ETDEWEB)

    Salarieh, Hassan [Center of Excellence in Design, Robotics and Automation, Department of Mechanical Engineering, Sharif University of Technology, P.O. Box 11365-9567, Tehran (Iran, Islamic Republic of)], E-mail: salarieh@mech.sharif.edu; Alasty, Aria [Center of Excellence in Design, Robotics and Automation, Department of Mechanical Engineering, Sharif University of Technology, P.O. Box 11365-9567, Tehran (Iran, Islamic Republic of)

    2008-08-15

    In this paper the problem of chaos control in nonlinear maps using minimization of entropy function is investigated. Invariant probability measure of a chaotic dynamics can be used to produce an entropy function in the sense of Shannon. In this paper it is shown that how the entropy control technique is utilized for chaos elimination. Using only the measured states of a chaotic map the probability measure of the system is numerically estimated and this estimated measure is used to obtain an estimation for the entropy of the chaotic map. The control variable of the chaotic system is determined in such a way that the entropy function descends until the chaotic trajectory of the map is replaced with a regular one. The proposed idea is applied for stabilizing the fixed points of the logistic and the Henon maps as some cases of study. Simulation results show the effectiveness of the method in chaos rejection when only the statistical information is available from the under-study systems.

  20. Realworld maximum power point tracking simulation of PV system based on Fuzzy Logic control

    Science.gov (United States)

    Othman, Ahmed M.; El-arini, Mahdi M. M.; Ghitas, Ahmed; Fathy, Ahmed

    2012-12-01

    In the recent years, the solar energy becomes one of the most important alternative sources of electric energy, so it is important to improve the efficiency and reliability of the photovoltaic (PV) systems. Maximum power point tracking (MPPT) plays an important role in photovoltaic power systems because it maximize the power output from a PV system for a given set of conditions, and therefore maximize their array efficiency. This paper presents a maximum power point tracker (MPPT) using Fuzzy Logic theory for a PV system. The work is focused on the well known Perturb and Observe (P&O) algorithm and is compared to a designed fuzzy logic controller (FLC). The simulation work dealing with MPPT controller; a DC/DC Ćuk converter feeding a load is achieved. The results showed that the proposed Fuzzy Logic MPPT in the PV system is valid.

  1. Mobile point sensors and actuators in the controllability theory of partial differential equations

    CERN Document Server

    Khapalov, Alexander Y

    2017-01-01

    This book presents a concise study of controllability theory of partial differential equations when they are equipped with actuators and/or sensors that are finite dimensional at every moment of time. Based on the author’s extensive research in the area of controllability theory, this monograph specifically focuses on the issues of controllability, observability, and stabilizability for parabolic and hyperbolic partial differential equations. The topics in this book also cover related applied questions such as the problem of localization of unknown pollution sources based on information obtained from point sensors that arise in environmental monitoring. Researchers and graduate students interested in controllability theory of partial differential equations and its applications will find this book to be an invaluable resource to their studies.

  2. Evaluation of the Leap Motion Controller as a New Contact-Free Pointing Device

    OpenAIRE

    Bachmann, Daniel; Weichert, Frank; Rinkenauer, Gerhard

    2014-01-01

    This paper presents a Fitts' law-based analysis of the user's performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC) is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8 % for the LMC and 2.8% for the mouse device, movement times...

  3. Synergies in the space of control variables within the equilibrium-point hypothesis.

    Science.gov (United States)

    Ambike, S; Mattos, D; Zatsiorsky, V M; Latash, M L

    2016-02-19

    We use an approach rooted in the recent theory of synergies to analyze possible co-variation between two hypothetical control variables involved in finger force production based on the equilibrium-point (EP) hypothesis. These control variables are the referent coordinate (R) and apparent stiffness (C) of the finger. We tested a hypothesis that inter-trial co-variation in the {R; C} space during repeated, accurate force production trials stabilizes the fingertip force. This was expected to correspond to a relatively low amount of inter-trial variability affecting force and a high amount of variability keeping the force unchanged. We used the "inverse piano" apparatus to apply small and smooth positional perturbations to fingers during force production tasks. Across trials, R and C showed strong co-variation with the data points lying close to a hyperbolic curve. Hyperbolic regressions accounted for over 99% of the variance in the {R; C} space. Another analysis was conducted by randomizing the original {R; C} data sets and creating surrogate data sets that were then used to compute predicted force values. The surrogate sets always showed much higher force variance compared to the actual data, thus reinforcing the conclusion that finger force control was organized in the {R; C} space, as predicted by the EP hypothesis, and involved co-variation in that space stabilizing total force. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  4. Salivary alpha-amylase and cortisol responsiveness following electrical stimulation stress in major depressive disorder patients.

    Science.gov (United States)

    Tanaka, Yoshihiro; Ishitobi, Yoshinobu; Maruyama, Yoshihiro; Kawano, Aimi; Ando, Tomoko; Okamoto, Shizuko; Kanehisa, Masayuki; Higuma, Haruka; Ninomiya, Taiga; Tsuru, Jusen; Hanada, Hiroaki; Kodama, Kensuke; Isogawa, Koichi; Akiyoshi, Jotaro

    2012-03-30

    Major depressive disorder (MDD) is often associated with dysregulation of the hypothalamic-pituitary-adrenal (HPA) axis by chronic stress. In comparison, psychosocial stress-induced activation of salivary α-amylase (sAA) functions as a marker of sympathoadrenal medullary system (SAM) activity. However, in contrast to salivary cortisol, sAA has been less extensively studied in MDD patients. The present study measured sAA and salivary cortisol levels in patients with MDD. The authors determined Profile of Mood State (POMS) and State-Trait anxiety Inventory (STAI) scores, Heart Rate Variability (HRV), and sAA and salivary cortisol levels in 88 patients with MDD and 41 healthy volunteers following the application of electrical stimulation stress. Patients with major depressive disorder were 8 points or more on Hamilton Depression Scale (HAM-D) scores. Tension-Anxiety, Depression-Dejection, Anger-Hostility, Fatigue, and Confusion scores in patients with major depressive disorder were significantly increased compared to healthy controls. In contrast, Vigor scores in patients with MDD were significantly decreased compared with healthy controls. There was no difference in heart rate variability measures between MDD patients and healthy controls. The threshold of electrical stimulation applied in MDD patients was lower than that in healthy controls. SAA levels in female MDD patients were significantly elevated relative to controls both before and after electrical stimulation. Finally, there were no differences in salivary cortisol levels between major depressive patients and controls. In the present study only three time points were explored. Furthermore, the increased secretion of sAA before and after stimulation could allude to an increased responsiveness of novel and uncontrollable situations in patients with MDD. These preliminary results suggest that sAA might be a useful biological marker of MDD. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Populating a Control Point Database: A cooperative effort between the USGS, Grand Canyon Monitoring and Research Center and the Grand Canyon Youth Organization

    Science.gov (United States)

    Brown, K. M.; Fritzinger, C.; Wharton, E.

    2004-12-01

    The Grand Canyon Monitoring and Research Center measures the effects of Glen Canyon Dam operations on the resources along the Colorado River from Glen Canyon Dam to Lake Mead in support of the Grand Canyon Adaptive Management Program. Control points are integral for geo-referencing the myriad of data collected in the Grand Canyon including aerial photography, topographic and bathymetric data used for classification and change-detection analysis of physical, biologic and cultural resources. The survey department has compiled a list of 870 control points installed by various organizations needing to establish a consistent reference for data collected at field sites along the 240 mile stretch of Colorado River in the Grand Canyon. This list is the foundation for the Control Point Database established primarily for researchers, to locate control points and independently geo-reference collected field data. The database has the potential to be a valuable mapping tool for assisting researchers to easily locate a control point and reduce the occurrance of unknowingly installing new control points within close proximity of an existing control point. The database is missing photographs and accurate site description information. Current site descriptions do not accurately define the location of the point but refer to the project that used the point, or some other interesting fact associated with the point. The Grand Canyon Monitoring and Research Center (GCMRC) resolved this problem by turning the data collection effort into an educational exercise for the participants of the Grand Canyon Youth organization. Grand Canyon Youth is a non-profit organization providing experiential education for middle and high school aged youth. GCMRC and the Grand Canyon Youth formed a partnership where GCMRC provided the logistical support, equipment, and training to conduct the field work, and the Grand Canyon Youth provided the time and personnel to complete the field work. Two data

  6. Regional control of Drosophila gut stem cell proliferation: EGF establishes GSSC proliferative set point & controls emergence from quiescence.

    Science.gov (United States)

    Strand, Marie; Micchelli, Craig A

    2013-01-01

    Adult stem cells vary widely in their rates of proliferation. Some stem cells are constitutively active, while others divide only in response to injury. The mechanism controlling this differential proliferative set point is not well understood. The anterior-posterior (A/P) axis of the adult Drosophila midgut has a segmental organization, displaying physiological compartmentalization and region-specific epithelia. These distinct midgut regions are maintained by defined stem cell populations with unique division schedules, providing an excellent experimental model with which to investigate this question. Here, we focus on the quiescent gastric stem cells (GSSCs) of the acidic copper cell region (CCR), which exhibit the greatest period of latency between divisions of all characterized gut stem cells, to define the molecular basis of differential stem cell activity. Our molecular genetic analysis demonstrates that the mitogenic EGF signaling pathway is a limiting factor controlling GSSC proliferation. We find that under baseline conditions, when GSSCs are largely quiescent, the lowest levels of EGF ligands in the midgut are found in the CCR. However, acute epithelial injury by enteric pathogens leads to an increase in EGF ligand expression in the CCR and rapid expansion of the GSSC lineage. Thus, the unique proliferative set points for gut stem cells residing in physiologically distinct compartments are governed by regional control of niche signals along the A/P axis.

  7. Regional control of Drosophila gut stem cell proliferation: EGF establishes GSSC proliferative set point & controls emergence from quiescence.

    Directory of Open Access Journals (Sweden)

    Marie Strand

    Full Text Available Adult stem cells vary widely in their rates of proliferation. Some stem cells are constitutively active, while others divide only in response to injury. The mechanism controlling this differential proliferative set point is not well understood. The anterior-posterior (A/P axis of the adult Drosophila midgut has a segmental organization, displaying physiological compartmentalization and region-specific epithelia. These distinct midgut regions are maintained by defined stem cell populations with unique division schedules, providing an excellent experimental model with which to investigate this question. Here, we focus on the quiescent gastric stem cells (GSSCs of the acidic copper cell region (CCR, which exhibit the greatest period of latency between divisions of all characterized gut stem cells, to define the molecular basis of differential stem cell activity. Our molecular genetic analysis demonstrates that the mitogenic EGF signaling pathway is a limiting factor controlling GSSC proliferation. We find that under baseline conditions, when GSSCs are largely quiescent, the lowest levels of EGF ligands in the midgut are found in the CCR. However, acute epithelial injury by enteric pathogens leads to an increase in EGF ligand expression in the CCR and rapid expansion of the GSSC lineage. Thus, the unique proliferative set points for gut stem cells residing in physiologically distinct compartments are governed by regional control of niche signals along the A/P axis.

  8. Fuzzy sliding mode control for maximum power point tracking of a photovoltaic pumping system

    Directory of Open Access Journals (Sweden)

    Sabah Miqoi

    2017-03-01

    Full Text Available In this paper a new maximum power point tracking method based on fuzzy sliding mode control is proposed, and employed in a PV water pumping system based on a DC-DC boost converter, to produce maximum power from the solar panel hence more speed in the DC motor and more water quantity. This method combines two different tracking techniques sliding mode control and fuzzy logic; our controller is based on sliding mode control, then to give better stability and enhance the power production a fuzzy logic technique was added. System modeling, sliding method definition and the new control method presentation are represented in this paper. The results of the simulation that are compared to both sliding mode controller and perturbation and observation method demonstrate effectiveness and robustness of the proposed controller.

  9. The "Russian roulette" of soccer? : Perceived control and anxiety in a major tournament penalty shootout

    NARCIS (Netherlands)

    Jordet, Geir; T Elferink-Gemser, Marije; Lemmink, Koen A. P. M.; Visscher, Chris

    2006-01-01

    Kicks from the penalty mark (official term for the "penalty shootout") are regularly featured in major soccer tournaments to determine the outcome of tied games. Based on the contingency-competence-control (CCC) model (Weisz & Stipek, 1982), this study provides an examination of the control beliefs

  10. Treatment of myofascial trigger points in female patients with chronic tension-type headache - A randomized controlled trial

    DEFF Research Database (Denmark)

    Berggreen, S.; Wiik, E.; Lund, Hans

    2012-01-01

    The aim of this study was to evaluate the efficacy of myofascial trigger point massage in the muscles of the head, neck and shoulders regarding pain in the treatment of females with chronic tension-type headache. They were randomized into either a treatment group (n = 20) (one session of trigger......: 8.8 (95% CI 0.1117.4), p = 0.047). Furthermore, a significant decrease in the number of trigger points was observed in the treatment group compared with the control group. Myofascial trigger point massage has a beneficial effect on pain in female patients with chronic tension-type headache....... point massage per week for 10 weeks) or a control group receiving no treatment (n = 19). The patients kept a diary to record their pain on a visual analogue scale (VAS), and the daily intake of drugs (mg) during the 4 weeks before and after the treatment period. The McGill Pain Questionnaire...

  11. Family psychoeducation for major depressive disorder - study protocol for a randomized controlled trial

    DEFF Research Database (Denmark)

    Timmerby, Nina; Austin, Stephen F; Ussing, Kristian

    2016-01-01

    BACKGROUND: Major depressive disorder has been shown to affect many domains of family life including family functioning. Conversely, the influence of the family on the course of the depression, including the risk of relapse, is one reason for targeting the family in interventions. The few studies...... will investigate the effect of family psychoeducation compared to social support on the course of the illness in patients with major depressive disorder. METHOD/DESIGN: The study is designed as a dual center, two-armed, observer-blinded, randomized controlled trial. Relatives are randomized to participate in one...

  12. Recommendations for dealing with waste contaminated with Ebola virus: a Hazard Analysis of Critical Control Points approach.

    Science.gov (United States)

    Edmunds, Kelly L; Elrahman, Samira Abd; Bell, Diana J; Brainard, Julii; Dervisevic, Samir; Fedha, Tsimbiri P; Few, Roger; Howard, Guy; Lake, Iain; Maes, Peter; Matofari, Joseph; Minnigh, Harvey; Mohamedani, Ahmed A; Montgomery, Maggie; Morter, Sarah; Muchiri, Edward; Mudau, Lutendo S; Mutua, Benedict M; Ndambuki, Julius M; Pond, Katherine; Sobsey, Mark D; van der Es, Mike; Zeitoun, Mark; Hunter, Paul R

    2016-06-01

    To assess, within communities experiencing Ebola virus outbreaks, the risks associated with the disposal of human waste and to generate recommendations for mitigating such risks. A team with expertise in the Hazard Analysis of Critical Control Points framework identified waste products from the care of individuals with Ebola virus disease and constructed, tested and confirmed flow diagrams showing the creation of such products. After listing potential hazards associated with each step in each flow diagram, the team conducted a hazard analysis, determined critical control points and made recommendations to mitigate the transmission risks at each control point. The collection, transportation, cleaning and shared use of blood-soiled fomites and the shared use of latrines contaminated with blood or bloodied faeces appeared to be associated with particularly high levels of risk of Ebola virus transmission. More moderate levels of risk were associated with the collection and transportation of material contaminated with bodily fluids other than blood, shared use of latrines soiled with such fluids, the cleaning and shared use of fomites soiled with such fluids, and the contamination of the environment during the collection and transportation of blood-contaminated waste. The risk of the waste-related transmission of Ebola virus could be reduced by the use of full personal protective equipment, appropriate hand hygiene and an appropriate disinfectant after careful cleaning. Use of the Hazard Analysis of Critical Control Points framework could facilitate rapid responses to outbreaks of emerging infectious disease.

  13. High performance control strategy for single-phase three-level neutral-point-clamped traction four-quadrant converters

    DEFF Research Database (Denmark)

    Kejian, Song; Konstantinou, Georgios; Jing, Li

    2017-01-01

    Operational data from Chinese railways indicate a number of challenges for traction four-quadrant converter (4QC) control including low-order voltage and current harmonics and reference tracking. A control strategy for a single-phase three-level neutral-point-clamped 4QC employed in the electric...

  14. Morphological control in polymer solar cells using low-boiling-point solvent additives

    Science.gov (United States)

    Mahadevapuram, Rakesh C.

    In the global search for clean, renewable energy sources, organic photovoltaics (OPVs) have recently been given much attention. Popular modern-day OPVs are made from solution-processible, carbon-based polymers (e.g. the model poly(3-hexylthiophene) that are intimately blended with fullerene derivatives (e.g. [6,6]-phenyl-C71-butyric acid methyl ester) to form what is known as the dispersed bulk-heterojunction (BHJ). This BHJ architecture has produced some of the most efficient OPVs to date, with reports closing in on 10% power conversion efficiency. To push efficiencies further into double digits, many groups have identified the BHJ nanomorphology---that is, the phase separations and grain sizes within the polymer: fullerene composite---as a key aspect in need of control and improvement. As a result, many methods, including thermal annealing, slow-drying (solvent) annealing, vapor annealing, and solvent additives, have been developed and studied to promote BHJ self-organization. Processing organic photovoltaic (OPV) blend solutions with high-boiling-point solvent additives has recently been used for morphological control in BHJ OPV cells. Here we show that even low-boiling-point solvents can be effective additives. When P3HT:PCBM OPV cells were processed with a low-boiling-point solvent tetrahydrafuran as an additive in parent solvent o-dichlorobenzene, charge extraction increased leading to fill factors as high as 69.5%, without low work-function cathodes, electrode buffer layers or thermal treatment. This was attributed to PCBM demixing from P3HT domains and better vertical phase separation, as indicated by photoluminescence lifetimes, hole mobilities, and shunt leakage currents. Dependence on solvent parameters and applicability beyond P3HT system was also investigated.

  15. Acupuncture point injection treatment of primary dysmenorrhoea: a randomised, double blind, controlled study.

    Science.gov (United States)

    Wade, C; Wang, L; Zhao, W J; Cardini, F; Kronenberg, F; Gui, S Q; Ying, Z; Zhao, N Q; Chao, M T; Yu, J

    2016-01-05

    To determine if injection of vitamin K3 in an acupuncture point is optimal for the treatment of primary dysmenorrhoea, when compared with 2 other injection treatments. A Menstrual Disorder Centre at a public hospital in Shanghai, China. Chinese women aged 14-25 years with severe primary dysmenorrhoea for at least 6 months not relieved by any other treatment were recruited. Exclusion criteria were the use of oral contraceptives, intrauterine devices or anticoagulant drugs, pregnancy, history of abdominal surgery, participation in other therapies for pain and diagnosis of secondary dysmenorrhoea. Eighty patients with primary dysmenorrhoea, as defined on a 4-grade scale, completed the study. Two patients withdrew after randomisation. A double-blind, double-dummy, randomised controlled trial compared vitamin K3 acupuncture point injection to saline acupuncture point injection and vitamin K3 deep muscle injection. Patients in each group received 3 injections at a single treatment visit. The primary outcome was the difference in subjective perception of pain as measured by an 11 unit Numeric Rating Scale (NRS). Secondary measurements were Cox Pain Intensity and Duration scales and the consumption of analgesic tablets before and after treatment and during 6 following cycles. Patients in all 3 groups experienced pain relief from the injection treatments. Differences in NRS measured mean pain scores between the 2 active control groups were less than 1 unit (-0.71, CI -1.37 to -0.05) and not significant, but the differences in average scores between the treatment hypothesised to be optimal and both active control groups (1.11, CI 0.45 to 1.78) and (1.82, CI 1.45 to 2.49) were statistically significant in adjusted mixed-effects models. Menstrual distress and use of analgesics were diminished for 6 months post-treatment. Acupuncture point injection of vitamin K3 relieves menstrual pain rapidly and is a useful treatment in an urban outpatient clinic. NCT00104546; Results

  16. Realworld maximum power point tracking simulation of PV system based on Fuzzy Logic control

    Directory of Open Access Journals (Sweden)

    Ahmed M. Othman

    2012-12-01

    Full Text Available In the recent years, the solar energy becomes one of the most important alternative sources of electric energy, so it is important to improve the efficiency and reliability of the photovoltaic (PV systems. Maximum power point tracking (MPPT plays an important role in photovoltaic power systems because it maximize the power output from a PV system for a given set of conditions, and therefore maximize their array efficiency. This paper presents a maximum power point tracker (MPPT using Fuzzy Logic theory for a PV system. The work is focused on the well known Perturb and Observe (P&O algorithm and is compared to a designed fuzzy logic controller (FLC. The simulation work dealing with MPPT controller; a DC/DC Ćuk converter feeding a load is achieved. The results showed that the proposed Fuzzy Logic MPPT in the PV system is valid.

  17. A Maximum Power Point Tracking Control Method of a Photovoltaic Power Generator with Consideration of Dynamic Characteristics of Solar Cells

    Science.gov (United States)

    Watanabe, Takashi; Yoshida, Toshiya; Ohniwa, Katsumi

    This paper discusses a new control strategy for photovoltaic power generation systems with consideration of dynamic characteristics of the photovoltaic cells. The controller estimates internal currents of an equivalent circuit for the cells. This estimated, or the virtual current and the actual voltage of the cells are fed to a conventional Maximum-Power-Point-Tracking (MPPT) controller. Consequently, this MPPT controller still tracks the optimum point even though it is so designed that the seeking speed of the operating point is extremely high. This system may suit for applications, which are installed in rapidly changeable insolation and temperature-conditions e.g. automobiles, trains, and airplanes. The proposed method is verified by experiment with a combination of this estimating function and the modified Boehringer's MPPT algorithm.

  18. Abnormal proactive and reactive cognitive control during conflict processing in major depression.

    Science.gov (United States)

    Vanderhasselt, Marie-Anne; De Raedt, Rudi; De Paepe, Annick; Aarts, Kristien; Otte, Georges; Van Dorpe, Jan; Pourtois, Gilles

    2014-02-01

    According to the Dual Mechanisms of Control framework, cognitive control consists of two complementary components: proactive control refers to anticipatory maintenance of goal-relevant information, whereas reactive control acts as a correction mechanism that is activated when a conflict occurs. Possibly, the well-known diminished inhibitory control in response to negative stimuli in Major Depressive Disorder (MDD) patients stems from a breakdown in proactive control, and/or anomalies in reactive cognitive control. In our study, MDD patients specifically showed increased response latencies when actively inhibiting a dominant response to a sad compared with a happy face. This condition was associated with a longer duration of a dominant ERP topography (800-900 ms poststimulus onset) and a stronger activity in the bilateral dorsal anterior cingulate cortex, reflecting abnormal reactive control when inhibiting attention to a negative stimulus. Moreover, MDD patients showed abnormalities in proactive cognitive control when preparing for the upcoming imperative stimulus (abnormal modulation of the contingent negative variation component), accompanied by more activity in brain regions belonging to the default mode network. All together, deficits to inhibit attention to negative information in MDD might originate from an abnormal use of both proactive resources and reactive control processes. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  19. Spin-valves with modified synthetic antiferromagnets exhibiting an enhanced bias point control capability at submicrometer dimensions

    International Nuclear Information System (INIS)

    Park, J.-S.; Lee, S.-R.; Kim, Y.K.

    2004-01-01

    Bias point control is of practical importance for operating read sensors for magnetic recording and magnetic random access memory devices. To attain bias point control capability, in particular, at submicrometer cell size, a modified synthetic antiferromagnet-based spin-valve (MSSV) structure was devised. A series of calculations were carried out to investigate the effect of size variation on their MR transfer behaviors. The cell dimension was varied from 10 to 0.05 μm. The typical MSSV comprises IrMn (9.0)/CoFe (P1, 1.5)/Ru (0.7)/CoFe (P2, 3.0)/Ru (0.7)/CoFe (P3, 1.5)/Cu (2.8)/CoFe (1.6)/NiFe (3.2) (in nm). As the cell size decreased, the bias point in the MSSV maintained nearly zero regardless of the cell size. The bias point was further tuned by varying the P3 layer thickness. Moreover, the effective exchange field (H ex.eff ) of the MSSV was much larger than that of the conventional SSV. The field sensitivity of the MSSV was very high indicating that the free layer can rotate more sharply

  20. Spin-valves with modified synthetic antiferromagnets exhibiting an enhanced bias point control capability at submicrometer dimensions

    Science.gov (United States)

    Park, Jeong-Suk; Lee, Seong-Rae; Kim, Young Keun

    2004-08-01

    Bias point control is of practical importance for operating read sensors for magnetic recording and magnetic random access memory devices. To attain bias point control capability, in particular, at submicrometer cell size, a modified synthetic antiferromagnet-based spin-valve (MSSV) structure was devised. A series of calculations were carried out to investigate the effect of size variation on their MR transfer behaviors. The cell dimension was varied from 10 to 0.05 μm. The typical MSSV comprises IrMn (9.0)/CoFe (P1, 1.5)/Ru (0.7)/CoFe (P2, 3.0)/Ru (0.7)/CoFe (P3, 1.5)/Cu (2.8)/CoFe (1.6)/NiFe (3.2) (in nm). As the cell size decreased, the bias point in the MSSV maintained nearly zero regardless of the cell size. The bias point was further tuned by varying the P3 layer thickness. Moreover, the effective exchange field ( Hex.eff) of the MSSV was much larger than that of the conventional SSV. The field sensitivity of the MSSV was very high indicating that the free layer can rotate more sharply.

  1. Dynamic range majority data structures

    DEFF Research Database (Denmark)

    Elmasry, Amr Ahmed Abd Elmoneim; He, Meng; Munro, J. Ian

    2011-01-01

    Given a set P of n coloured points on the real line, we study the problem of answering range α-majority (or "heavy hitter") queries on P. More specifically, for a query range Q, we want to return each colour that is assigned to more than an α-fraction of the points contained in Q. We present a ne...

  2. New Zealand tobacco retailers' attitudes to selling tobacco, point-of-sale display bans and other tobacco control measures: a qualitative analysis.

    Science.gov (United States)

    Jaine, Richard; Russell, Marie; Edwards, Richard; Thomson, George

    2014-06-20

    We aimed to explore New Zealand tobacco retailers' views on selling tobacco, the forthcoming 2012 point of sale display ban and two other potential tobacco control interventions in the retail setting: compulsory sales of nicotine replacement therapy and licensing of tobacco retailers. We carried out in-depth interviews with 18 retailers from a variety of store types where tobacco was sold. Stores were selected from a range of locations with varying levels of deprivation. We used thematic analysis to analyse the data. All but four of the retailers were ambivalent about selling tobacco, would rather not sell it, or fell back on a business imperative for justification. Only one retailer was explicitly unconcerned about selling tobacco products. Most participants had few or no concerns about the removal of point-of-sale displays. Issues which were raised were mainly practical and logistical issues with the removal of displays. Only three thought sales would definitely be reduced. The majority of the retailers were not opposed to a possible requirement that nicotine replacement therapy products be made available wherever tobacco products are sold. Ten supported a licensing or registration scheme for tobacco retailers, and only three were opposed. We found widespread ambivalence about selling tobacco. There was considerable support for the licensing of tobacco retailers and other potential tobacco control measures. The retailers' attitudes about potential financial costs and security issues from a tobacco display ban were at odds with the tobacco industry predictions and the views of retailers' organisations. Some retailers appear to be potential allies for tobacco control. This is in contrast to retailer organisations, which may be out of step with many of their members in their strong opposition to retail tobacco control interventions.

  3. A Low-Cost Maximum Power Point Tracking System Based on Neural Network Inverse Model Controller

    Directory of Open Access Journals (Sweden)

    Carlos Robles Algarín

    2018-01-01

    Full Text Available This work presents the design, modeling, and implementation of a neural network inverse model controller for tracking the maximum power point of a photovoltaic (PV module. A nonlinear autoregressive network with exogenous inputs (NARX was implemented in a serial-parallel architecture. The PV module mathematical modeling was developed, a buck converter was designed to operate in the continuous conduction mode with a switching frequency of 20 KHz, and the dynamic neural controller was designed using the Neural Network Toolbox from Matlab/Simulink (MathWorks, Natick, MA, USA, and it was implemented on an open-hardware Arduino Mega board. To obtain the reference signals for the NARX and determine the 65 W PV module behavior, a system made of a 0.8 W PV cell, a temperature sensor, a voltage sensor and a static neural network, was used. To evaluate performance a comparison with the P&O traditional algorithm was done in terms of response time and oscillations around the operating point. Simulation results demonstrated the superiority of neural controller over the P&O. Implementation results showed that approximately the same power is obtained with both controllers, but the P&O controller presents oscillations between 7 W and 10 W, in contrast to the inverse controller, which had oscillations between 1 W and 2 W.

  4. Elevated serum levels of malondialdehyde and cortisol are associated with major depressive disorder: A case-control study.

    Science.gov (United States)

    Islam, Md Rabiul; Islam, Md Reazul; Ahmed, Imtiaz; Moktadir, Abdullah Al; Nahar, Zabun; Islam, Mohammad Safiqul; Shahid, Shelina Fatema Binte; Islam, Sheikh Nazrul; Islam, Md Saiful; Hasnat, Abul

    2018-01-01

    Major depressive disorder is diagnosed on the basis of patient's self-reported experiences, behavior reported by relatives, and a mental status examination, and yet we do not have any reliable biomarker for this. Mood-regulating pathways are affected by oxidative injury to lipids and cortisol is released into the blood due to stimulation of corticotrophin receptors in the adrenal cortex. Here, we aimed to determine serum levels of malondialdehyde and cortisol in major depressive disorder patients and controls. We collected blood samples from 247 major depressive disorder patients and 248 controls. Serum levels of malondialdehyde and cortisol were measured by ultraviolet spectrophotometry and enzyme-linked immunosorbent assay kit, respectively. We found malondialdehyde levels were significantly higher in patients than controls, with mean ± standard deviation at 4.49 ± 1.37 and 2.87 ± 0.82 µmol/L, respectively, p  depressive disorder. We believe elevations of malondialdehyde and cortisol in serum level arise independently and they could serve as biomarkers for major depressive disorder.

  5. Cost control and risk mitigation of major projects

    International Nuclear Information System (INIS)

    Caddy, D.G.

    1993-01-01

    In this paper and presentation, the four major types of estimates will be discussed, i.e., capacity factored, equipment factored, semi-detailed and detailed. Key relationships between particular portions of estimates will be discussed such as the relationship between direct field labor and indirect field costs. Having set the basis for developing a project's cost through estimating, the paper will then list and discuss the fifteen key steps which must be followed to control the costs of a project. Next, the subject of allowances and contingency will be discussed and defined and the differences between the two will be highlighted. Having established exactly what contingency is, the subject of risk analysis through RANGE estimating will be discussed. The methods used to establish a precise contingency and probability of an over/under run will be discussed. Finally, the paper will discuss the methods by which a project manager, owner or contractor can mitigate risks; that is to eliminate, transfer or minimize their effect

  6. Neuro Emotional Technique for the treatment of trigger point sensitivity in chronic neck pain sufferers: a controlled clinical trial.

    Science.gov (United States)

    Bablis, Peter; Pollard, Henry; Bonello, Rod

    2008-05-21

    Trigger points have been shown to be active in many myofascial pain syndromes. Treatment of trigger point pain and dysfunction may be explained through the mechanisms of central and peripheral paradigms. This study aimed to investigate whether the mind/body treatment of Neuro Emotional Technique (NET) could significantly relieve pain sensitivity of trigger points presenting in a cohort of chronic neck pain sufferers. Sixty participants presenting to a private chiropractic clinic with chronic cervical pain as their primary complaint were sequentially allocated into treatment and control groups. Participants in the treatment group received a short course of Neuro Emotional Technique that consists of muscle testing, general semantics and Traditional Chinese Medicine. The control group received a sham NET protocol. Outcome measurements included pain assessment utilizing a visual analog scale and a pressure gauge algometer. Pain sensitivity was measured at four trigger point locations: suboccipital region (S); levator scapulae region (LS); sternocleidomastoid region (SCM) and temporomandibular region (TMJ). For each outcome measurement and each trigger point, we calculated the change in measurement between pre- and post- treatment. We then examined the relationships between these measurement changes and six independent variables (i.e. treatment group and the above five additional participant variables) using forward stepwise General Linear Model. The visual analog scale (0 to 10) had an improvement of 7.6 at S, 7.2 at LS, 7.5 at SCM and 7.1 at the TMJ in the treatment group compared with no improvement of at S, and an improvement of 0.04 at LS, 0.1 at SCM and 0.1 at the TMJ point in the control group, (P algometer recordings of four trigger point locations in a cohort of chronic neck pain sufferers were significantly improved when compared to a control group which received a sham protocol of NET. Chronic neck pain sufferers may benefit from NET treatment in the relief

  7. Probabilistic safety assessment and optimal control of hazardous technological systems. A marked point process approach

    International Nuclear Information System (INIS)

    Holmberg, J.

    1997-04-01

    The thesis models risk management as an optimal control problem for a stochastic process. The approach classes the decisions made by management into three categories according to the control methods of a point process: (1) planned process lifetime, (2) modification of the design, and (3) operational decisions. The approach is used for optimization of plant shutdown criteria and surveillance test strategies of a hypothetical nuclear power plant

  8. Introduction of the system of hazard analysis critical control point to ensure the safety of irradiated food

    International Nuclear Information System (INIS)

    Sajet, A.S.

    2014-01-01

    Hazard Analysis Critical Control Point (HACCP) is a preventive system for food safety. It identifies safety risks faced by food. Identified points are controlled ensuring product safety. Because of presence of many of the pathogenic microorganisms and parasites in food which caused cases of food poisoning and many diseases transmitted through food, the current methods of food production could not prevent food contamination or prevent the growth of these pathogens completely because of being a part of the normal flora in the environment. Irradiation technology helped to control diseases transmitted through food, caused by pathological microorganisms and parasites present in food. The application of a system based on risk analysis as a means of risk management in food chain, demonstrated the importance of food irradiation. (author)

  9. Assessment of hygiene standards and Hazard Analysis Critical Control Points implementation on passenger ships.

    Science.gov (United States)

    Mouchtouri, Varavara; Malissiova, Eleni; Zisis, Panagiotis; Paparizou, Evina; Hadjichristodoulou, Christos

    2013-01-01

    The level of hygiene on ferries can have impact on travellers' health. The aim of this study was to assess the hygiene standards of ferries in Greece and to investigate whether Hazard Analysis Critical Control Points (HACCP) implementation contributes to the hygiene status and particularly food safety aboard passenger ships. Hygiene inspections on 17 ferries in Greece were performed using a standardized inspection form, with a 135-point scale. Thirty-four water and 17 food samples were collected and analysed. About 65% (11/17) of ferries were scored with >100 points. Ferries with HACCP received higher scores during inspection compared to those without HACCP (p value food samples, only one was found positive for Salmonella spp. Implementation of management systems including HACCP principles can help to raise the level of hygiene aboard passenger ships.

  10. Biogeochemical control points in a water-limited critical zone

    Science.gov (United States)

    Chorover, J.; Brooks, P. D.; Gallery, R. E.; McIntosh, J. C.; Olshansky, Y.; Rasmussen, C.

    2017-12-01

    The routing of water and carbon through complex terrain is postulated to control structure evolution in the sub-humid critical zone of the southwestern US. By combining measurements of land-atmosphere exchange, ecohydrologic partitioning, and subsurface biogeochemistry, we seek to quantify how a heterogeneous (in time and space) distribution of "reactants" impacts both short-term (sub-)catchment response (e.g., pore and surface water chemical dynamics) and long-term landscape evolution (e.g., soil geochemistry/morphology and regolith weathering depth) in watersheds underlain by rhyolite and schist. Instrumented pedons in convergent, planar, and divergent landscape positions show distinct depth-dependent responses to precipitation events. Wetting front propagation, dissolved carbon flux and associated biogeochemical responses (e.g., pulses of CO2 production, O2 depletion, solute release) vary with topography, revealing the influence of lateral subsidies of water and carbon. The impacts of these episodes on the evolution of porous media heterogeneity is being investigated by statistical analysis of pore water chemistry, chemical/spectroscopic studies of solid phase organo-mineral products, sensor-derived water characteristic curves, and quantification of co-located microbial community activity/composition. Our results highlight the interacting effects of critical zone structure and convergent hydrologic flows in the evolution of biogeochemical control points.

  11. AECB staff annual assessment of the Point Lepreau Nuclear Generating Station

    International Nuclear Information System (INIS)

    1997-06-01

    The Atomic Energy Control Board is the independent federal agency that controls all nuclear activities in Canada. A major use of nuclear energy in Canada is electricity production. The AECB assesses every station's performance against legal requirements, including the conditions in the operating licence. Each station is inspected and all aspects of the station's operation and management is reviewed. This report is the AECB staff assessment of reactor safety at the Point Lepreau Generating Station in 1996. Point Lepreau operated safely but the worsening trends in NB Power's safety performance leads to the conclusion that urgent action is required. NB Power is required to report formally to the AECB on progress with measures to improve safety management every six months. Further licensing action will be taken on NB Power if it fails to make the improvements

  12. Ground-based telescope pointing and tracking optimization using a neural controller.

    Science.gov (United States)

    Mancini, D; Brescia, M; Schipani, P

    2003-01-01

    Neural network models (NN) have emerged as important components for applications of adaptive control theories. Their basic generalization capability, based on acquired knowledge, together with execution rapidity and correlation ability between input stimula, are basic attributes to consider NN as an extremely powerful tool for on-line control of complex systems. By a control system point of view, not only accuracy and speed, but also, in some cases, a high level of adaptation capability is required in order to match all working phases of the whole system during its lifetime. This is particularly remarkable for a new generation ground-based telescope control system. Infact, strong changes in terms of system speed and instantaneous position error tolerance are necessary, especially in case of trajectory disturb induced by wind shake. The classical control scheme adopted in such a system is based on the proportional integral (PI) filter, already applied and implemented on a large amount of new generation telescopes, considered as a standard in this technological environment. In this paper we introduce the concept of a new approach, the neural variable structure proportional integral, (NVSPI), related to the implementation of a standard multi layer perceptron network in new generation ground-based Alt-Az telescope control systems. Its main purpose is to improve adaptive capability of the Variable structure proportional integral model, an already innovative control scheme recently introduced by authors [Proc SPIE (1997)], based on a modified version of classical PI control model, in terms of flexibility and accuracy of the dynamic response range also in presence of wind noise effects. The realization of a powerful well tested and validated telescope model simulation system allowed the possibility to directly compare performances of the two control schemes on simulated tracking trajectories, revealing extremely encouraging results in terms of NVSPI control robustness and

  13. Testing to fulfill HACCP (Hazard Analysis Critical Control Points) requirements: principles and examples.

    Science.gov (United States)

    Gardner, I A

    1997-12-01

    On-farm HACCP (hazard analysis critical control points) monitoring requires cost-effective, yet accurate and reproducible tests that can determine the status of cows, milk, and the dairy environment. Tests need to be field-validated, and their limitations need to be established so that appropriate screening strategies can be initiated and test results can be rationally interpreted. For infections and residues of low prevalence, tests or testing strategies that are highly specific help to minimize false-positive results and excessive costs to the dairy industry. The determination of the numbers of samples to be tested in HACCP monitoring programs depends on the specific purpose of the test and the likely prevalence of the agent or residue at the critical control point. The absence of positive samples from a herd test should not be interpreted as freedom from a particular agent or residue unless the entire herd has been tested with a test that is 100% sensitive. The current lack of field-validated tests for most of the chemical and infectious agents of concern makes it difficult to ensure that the stated goals of HACCP programs are consistently achieved.

  14. The major genetic determinants of HIV-1 control affect HLA class I peptide presentation.

    Science.gov (United States)

    Pereyra, Florencia; Jia, Xiaoming; McLaren, Paul J; Telenti, Amalio; de Bakker, Paul I W; Walker, Bruce D; Ripke, Stephan; Brumme, Chanson J; Pulit, Sara L; Carrington, Mary; Kadie, Carl M; Carlson, Jonathan M; Heckerman, David; Graham, Robert R; Plenge, Robert M; Deeks, Steven G; Gianniny, Lauren; Crawford, Gabriel; Sullivan, Jordan; Gonzalez, Elena; Davies, Leela; Camargo, Amy; Moore, Jamie M; Beattie, Nicole; Gupta, Supriya; Crenshaw, Andrew; Burtt, Noël P; Guiducci, Candace; Gupta, Namrata; Gao, Xiaojiang; Qi, Ying; Yuki, Yuko; Piechocka-Trocha, Alicja; Cutrell, Emily; Rosenberg, Rachel; Moss, Kristin L; Lemay, Paul; O'Leary, Jessica; Schaefer, Todd; Verma, Pranshu; Toth, Ildiko; Block, Brian; Baker, Brett; Rothchild, Alissa; Lian, Jeffrey; Proudfoot, Jacqueline; Alvino, Donna Marie L; Vine, Seanna; Addo, Marylyn M; Allen, Todd M; Altfeld, Marcus; Henn, Matthew R; Le Gall, Sylvie; Streeck, Hendrik; Haas, David W; Kuritzkes, Daniel R; Robbins, Gregory K; Shafer, Robert W; Gulick, Roy M; Shikuma, Cecilia M; Haubrich, Richard; Riddler, Sharon; Sax, Paul E; Daar, Eric S; Ribaudo, Heather J; Agan, Brian; Agarwal, Shanu; Ahern, Richard L; Allen, Brady L; Altidor, Sherly; Altschuler, Eric L; Ambardar, Sujata; Anastos, Kathryn; Anderson, Ben; Anderson, Val; Andrady, Ushan; Antoniskis, Diana; Bangsberg, David; Barbaro, Daniel; Barrie, William; Bartczak, J; Barton, Simon; Basden, Patricia; Basgoz, Nesli; Bazner, Suzane; Bellos, Nicholaos C; Benson, Anne M; Berger, Judith; Bernard, Nicole F; Bernard, Annette M; Birch, Christopher; Bodner, Stanley J; Bolan, Robert K; Boudreaux, Emilie T; Bradley, Meg; Braun, James F; Brndjar, Jon E; Brown, Stephen J; Brown, Katherine; Brown, Sheldon T; Burack, Jedidiah; Bush, Larry M; Cafaro, Virginia; Campbell, Omobolaji; Campbell, John; Carlson, Robert H; Carmichael, J Kevin; Casey, Kathleen K; Cavacuiti, Chris; Celestin, Gregory; Chambers, Steven T; Chez, Nancy; Chirch, Lisa M; Cimoch, Paul J; Cohen, Daniel; Cohn, Lillian E; Conway, Brian; Cooper, David A; Cornelson, Brian; Cox, David T; Cristofano, Michael V; Cuchural, George; Czartoski, Julie L; Dahman, Joseph M; Daly, Jennifer S; Davis, Benjamin T; Davis, Kristine; Davod, Sheila M; DeJesus, Edwin; Dietz, Craig A; Dunham, Eleanor; Dunn, Michael E; Ellerin, Todd B; Eron, Joseph J; Fangman, John J W; Farel, Claire E; Ferlazzo, Helen; Fidler, Sarah; Fleenor-Ford, Anita; Frankel, Renee; Freedberg, Kenneth A; French, Neel K; Fuchs, Jonathan D; Fuller, Jon D; Gaberman, Jonna; Gallant, Joel E; Gandhi, Rajesh T; Garcia, Efrain; Garmon, Donald; Gathe, Joseph C; Gaultier, Cyril R; Gebre, Wondwoosen; Gilman, Frank D; Gilson, Ian; Goepfert, Paul A; Gottlieb, Michael S; Goulston, Claudia; Groger, Richard K; Gurley, T Douglas; Haber, Stuart; Hardwicke, Robin; Hardy, W David; Harrigan, P Richard; Hawkins, Trevor N; Heath, Sonya; Hecht, Frederick M; Henry, W Keith; Hladek, Melissa; Hoffman, Robert P; Horton, James M; Hsu, Ricky K; Huhn, Gregory D; Hunt, Peter; Hupert, Mark J; Illeman, Mark L; Jaeger, Hans; Jellinger, Robert M; John, Mina; Johnson, Jennifer A; Johnson, Kristin L; Johnson, Heather; Johnson, Kay; Joly, Jennifer; Jordan, Wilbert C; Kauffman, Carol A; Khanlou, Homayoon; Killian, Robert K; Kim, Arthur Y; Kim, David D; Kinder, Clifford A; Kirchner, Jeffrey T; Kogelman, Laura; Kojic, Erna Milunka; Korthuis, P Todd; Kurisu, Wayne; Kwon, Douglas S; LaMar, Melissa; Lampiris, Harry; Lanzafame, Massimiliano; Lederman, Michael M; Lee, David M; Lee, Jean M L; Lee, Marah J; Lee, Edward T Y; Lemoine, Janice; Levy, Jay A; Llibre, Josep M; Liguori, Michael A; Little, Susan J; Liu, Anne Y; Lopez, Alvaro J; Loutfy, Mono R; Loy, Dawn; Mohammed, Debbie Y; Man, Alan; Mansour, Michael K; Marconi, Vincent C; Markowitz, Martin; Marques, Rui; Martin, Jeffrey N; Martin, Harold L; Mayer, Kenneth Hugh; McElrath, M Juliana; McGhee, Theresa A; McGovern, Barbara H; McGowan, Katherine; McIntyre, Dawn; Mcleod, Gavin X; Menezes, Prema; Mesa, Greg; Metroka, Craig E; Meyer-Olson, Dirk; Miller, Andy O; Montgomery, Kate; Mounzer, Karam C; Nagami, Ellen H; Nagin, Iris; Nahass, Ronald G; Nelson, Margret O; Nielsen, Craig; Norene, David L; O'Connor, David H; Ojikutu, Bisola O; Okulicz, Jason; Oladehin, Olakunle O; Oldfield, Edward C; Olender, Susan A; Ostrowski, Mario; Owen, William F; Pae, Eunice; Parsonnet, Jeffrey; Pavlatos, Andrew M; Perlmutter, Aaron M; Pierce, Michael N; Pincus, Jonathan M; Pisani, Leandro; Price, Lawrence Jay; Proia, Laurie; Prokesch, Richard C; Pujet, Heather Calderon; Ramgopal, Moti; Rathod, Almas; Rausch, Michael; Ravishankar, J; Rhame, Frank S; Richards, Constance Shamuyarira; Richman, Douglas D; Rodes, Berta; Rodriguez, Milagros; Rose, Richard C; Rosenberg, Eric S; Rosenthal, Daniel; Ross, Polly E; Rubin, David S; Rumbaugh, Elease; Saenz, Luis; Salvaggio, Michelle R; Sanchez, William C; Sanjana, Veeraf M; Santiago, Steven; Schmidt, Wolfgang; Schuitemaker, Hanneke; Sestak, Philip M; Shalit, Peter; Shay, William; Shirvani, Vivian N; Silebi, Vanessa I; Sizemore, James M; Skolnik, Paul R; Sokol-Anderson, Marcia; Sosman, James M; Stabile, Paul; Stapleton, Jack T; Starrett, Sheree; Stein, Francine; Stellbrink, Hans-Jurgen; Sterman, F Lisa; Stone, Valerie E; Stone, David R; Tambussi, Giuseppe; Taplitz, Randy A; Tedaldi, Ellen M; Telenti, Amalio; Theisen, William; Torres, Richard; Tosiello, Lorraine; Tremblay, Cecile; Tribble, Marc A; Trinh, Phuong D; Tsao, Alice; Ueda, Peggy; Vaccaro, Anthony; Valadas, Emilia; Vanig, Thanes J; Vecino, Isabel; Vega, Vilma M; Veikley, Wenoah; Wade, Barbara H; Walworth, Charles; Wanidworanun, Chingchai; Ward, Douglas J; Warner, Daniel A; Weber, Robert D; Webster, Duncan; Weis, Steve; Wheeler, David A; White, David J; Wilkins, Ed; Winston, Alan; Wlodaver, Clifford G; van't Wout, Angelique; Wright, David P; Yang, Otto O; Yurdin, David L; Zabukovic, Brandon W; Zachary, Kimon C; Zeeman, Beth; Zhao, Meng

    2010-12-10

    Infectious and inflammatory diseases have repeatedly shown strong genetic associations within the major histocompatibility complex (MHC); however, the basis for these associations remains elusive. To define host genetic effects on the outcome of a chronic viral infection, we performed genome-wide association analysis in a multiethnic cohort of HIV-1 controllers and progressors, and we analyzed the effects of individual amino acids within the classical human leukocyte antigen (HLA) proteins. We identified >300 genome-wide significant single-nucleotide polymorphisms (SNPs) within the MHC and none elsewhere. Specific amino acids in the HLA-B peptide binding groove, as well as an independent HLA-C effect, explain the SNP associations and reconcile both protective and risk HLA alleles. These results implicate the nature of the HLA-viral peptide interaction as the major factor modulating durable control of HIV infection.

  15. The Major Genetic Determinants of HIV-1 Control Affect HLA Class I Peptide Presentation

    Science.gov (United States)

    Pereyra, Florencia; Jia, Xiaoming; McLaren, Paul J.; Telenti, Amalio; de Bakker, Paul I.W.; Walker, Bruce D.; Jia, Xiaoming; McLaren, Paul J.; Ripke, Stephan; Brumme, Chanson J.; Pulit, Sara L.; Telenti, Amalio; Carrington, Mary; Kadie, Carl M.; Carlson, Jonathan M.; Heckerman, David; de Bakker, Paul I.W.; Pereyra, Florencia; de Bakker, Paul I.W.; Graham, Robert R.; Plenge, Robert M.; Deeks, Steven G.; Walker, Bruce D.; Gianniny, Lauren; Crawford, Gabriel; Sullivan, Jordan; Gonzalez, Elena; Davies, Leela; Camargo, Amy; Moore, Jamie M.; Beattie, Nicole; Gupta, Supriya; Crenshaw, Andrew; Burtt, Noël P.; Guiducci, Candace; Gupta, Namrata; Carrington, Mary; Gao, Xiaojiang; Qi, Ying; Yuki, Yuko; Pereyra, Florencia; Piechocka-Trocha, Alicja; Cutrell, Emily; Rosenberg, Rachel; Moss, Kristin L.; Lemay, Paul; O’Leary, Jessica; Schaefer, Todd; Verma, Pranshu; Toth, Ildiko; Block, Brian; Baker, Brett; Rothchild, Alissa; Lian, Jeffrey; Proudfoot, Jacqueline; Alvino, Donna Marie L.; Vine, Seanna; Addo, Marylyn M.; Allen, Todd M.; Altfeld, Marcus; Henn, Matthew R.; Le Gall, Sylvie; Streeck, Hendrik; Walker, Bruce D.; Haas, David W.; Kuritzkes, Daniel R.; Robbins, Gregory K.; Shafer, Robert W.; Gulick, Roy M.; Shikuma, Cecilia M.; Haubrich, Richard; Riddler, Sharon; Sax, Paul E.; Daar, Eric S.; Ribaudo, Heather J.; Agan, Brian; Agarwal, Shanu; Ahern, Richard L.; Allen, Brady L.; Altidor, Sherly; Altschuler, Eric L.; Ambardar, Sujata; Anastos, Kathryn; Anderson, Ben; Anderson, Val; Andrady, Ushan; Antoniskis, Diana; Bangsberg, David; Barbaro, Daniel; Barrie, William; Bartczak, J.; Barton, Simon; Basden, Patricia; Basgoz, Nesli; Bazner, Suzane; Bellos, Nicholaos C.; Benson, Anne M.; Berger, Judith; Bernard, Nicole F.; Bernard, Annette M.; Birch, Christopher; Bodner, Stanley J.; Bolan, Robert K.; Boudreaux, Emilie T.; Bradley, Meg; Braun, James F.; Brndjar, Jon E.; Brown, Stephen J.; Brown, Katherine; Brown, Sheldon T.; Burack, Jedidiah; Bush, Larry M.; Cafaro, Virginia; Campbell, Omobolaji; Campbell, John; Carlson, Robert H.; Carmichael, J. Kevin; Casey, Kathleen K.; Cavacuiti, Chris; Celestin, Gregory; Chambers, Steven T.; Chez, Nancy; Chirch, Lisa M.; Cimoch, Paul J.; Cohen, Daniel; Cohn, Lillian E.; Conway, Brian; Cooper, David A.; Cornelson, Brian; Cox, David T.; Cristofano, Michael V.; Cuchural, George; Czartoski, Julie L.; Dahman, Joseph M.; Daly, Jennifer S.; Davis, Benjamin T.; Davis, Kristine; Davod, Sheila M.; Deeks, Steven G.; DeJesus, Edwin; Dietz, Craig A.; Dunham, Eleanor; Dunn, Michael E.; Ellerin, Todd B.; Eron, Joseph J.; Fangman, John J.W.; Farel, Claire E.; Ferlazzo, Helen; Fidler, Sarah; Fleenor-Ford, Anita; Frankel, Renee; Freedberg, Kenneth A.; French, Neel K.; Fuchs, Jonathan D.; Fuller, Jon D.; Gaberman, Jonna; Gallant, Joel E.; Gandhi, Rajesh T.; Garcia, Efrain; Garmon, Donald; Gathe, Joseph C.; Gaultier, Cyril R.; Gebre, Wondwoosen; Gilman, Frank D.; Gilson, Ian; Goepfert, Paul A.; Gottlieb, Michael S.; Goulston, Claudia; Groger, Richard K.; Gurley, T. Douglas; Haber, Stuart; Hardwicke, Robin; Hardy, W. David; Harrigan, P. Richard; Hawkins, Trevor N.; Heath, Sonya; Hecht, Frederick M.; Henry, W. Keith; Hladek, Melissa; Hoffman, Robert P.; Horton, James M.; Hsu, Ricky K.; Huhn, Gregory D.; Hunt, Peter; Hupert, Mark J.; Illeman, Mark L.; Jaeger, Hans; Jellinger, Robert M.; John, Mina; Johnson, Jennifer A.; Johnson, Kristin L.; Johnson, Heather; Johnson, Kay; Joly, Jennifer; Jordan, Wilbert C.; Kauffman, Carol A.; Khanlou, Homayoon; Killian, Robert K.; Kim, Arthur Y.; Kim, David D.; Kinder, Clifford A.; Kirchner, Jeffrey T.; Kogelman, Laura; Kojic, Erna Milunka; Korthuis, P. Todd; Kurisu, Wayne; Kwon, Douglas S.; LaMar, Melissa; Lampiris, Harry; Lanzafame, Massimiliano; Lederman, Michael M.; Lee, David M.; Lee, Jean M.L.; Lee, Marah J.; Lee, Edward T.Y.; Lemoine, Janice; Levy, Jay A.; Llibre, Josep M.; Liguori, Michael A.; Little, Susan J.; Liu, Anne Y.; Lopez, Alvaro J.; Loutfy, Mono R.; Loy, Dawn; Mohammed, Debbie Y.; Man, Alan; Mansour, Michael K.; Marconi, Vincent C.; Markowitz, Martin; Marques, Rui; Martin, Jeffrey N.; Martin, Harold L.; Mayer, Kenneth Hugh; McElrath, M. Juliana; McGhee, Theresa A.; McGovern, Barbara H.; McGowan, Katherine; McIntyre, Dawn; Mcleod, Gavin X.; Menezes, Prema; Mesa, Greg; Metroka, Craig E.; Meyer-Olson, Dirk; Miller, Andy O.; Montgomery, Kate; Mounzer, Karam C.; Nagami, Ellen H.; Nagin, Iris; Nahass, Ronald G.; Nelson, Margret O.; Nielsen, Craig; Norene, David L.; O’Connor, David H.; Ojikutu, Bisola O.; Okulicz, Jason; Oladehin, Olakunle O.; Oldfield, Edward C.; Olender, Susan A.; Ostrowski, Mario; Owen, William F.; Pae, Eunice; Parsonnet, Jeffrey; Pavlatos, Andrew M.; Perlmutter, Aaron M.; Pierce, Michael N.; Pincus, Jonathan M.; Pisani, Leandro; Price, Lawrence Jay; Proia, Laurie; Prokesch, Richard C.; Pujet, Heather Calderon; Ramgopal, Moti; Rathod, Almas; Rausch, Michael; Ravishankar, J.; Rhame, Frank S.; Richards, Constance Shamuyarira; Richman, Douglas D.; Robbins, Gregory K.; Rodes, Berta; Rodriguez, Milagros; Rose, Richard C.; Rosenberg, Eric S.; Rosenthal, Daniel; Ross, Polly E.; Rubin, David S.; Rumbaugh, Elease; Saenz, Luis; Salvaggio, Michelle R.; Sanchez, William C.; Sanjana, Veeraf M.; Santiago, Steven; Schmidt, Wolfgang; Schuitemaker, Hanneke; Sestak, Philip M.; Shalit, Peter; Shay, William; Shirvani, Vivian N.; Silebi, Vanessa I.; Sizemore, James M.; Skolnik, Paul R.; Sokol-Anderson, Marcia; Sosman, James M.; Stabile, Paul; Stapleton, Jack T.; Starrett, Sheree; Stein, Francine; Stellbrink, Hans-Jurgen; Sterman, F. Lisa; Stone, Valerie E.; Stone, David R.; Tambussi, Giuseppe; Taplitz, Randy A.; Tedaldi, Ellen M.; Telenti, Amalio; Theisen, William; Torres, Richard; Tosiello, Lorraine; Tremblay, Cecile; Tribble, Marc A.; Trinh, Phuong D.; Tsao, Alice; Ueda, Peggy; Vaccaro, Anthony; Valadas, Emilia; Vanig, Thanes J.; Vecino, Isabel; Vega, Vilma M.; Veikley, Wenoah; Wade, Barbara H.; Walworth, Charles; Wanidworanun, Chingchai; Ward, Douglas J.; Warner, Daniel A.; Weber, Robert D.; Webster, Duncan; Weis, Steve; Wheeler, David A.; White, David J.; Wilkins, Ed; Winston, Alan; Wlodaver, Clifford G.; Wout, Angelique van’t; Wright, David P.; Yang, Otto O.; Yurdin, David L.; Zabukovic, Brandon W.; Zachary, Kimon C.; Zeeman, Beth; Zhao, Meng

    2011-01-01

    Infectious and inflammatory diseases have repeatedly shown strong genetic associations within the major histocompatibility complex (MHC); however, the basis for these associations remains elusive. To define host genetic effects on the outcome of a chronic viral infection, we performed genome-wide association analysis in a multiethnic cohort of HIV-1 controllers and progressors, and we analyzed the effects of individual amino acids within the classical human leukocyte antigen (HLA) proteins. We identified >300 genome-wide significant single-nucleotide polymorphisms (SNPs) within the MHC and none elsewhere. Specific amino acids in the HLA-B peptide binding groove, as well as an independent HLA-C effect, explain the SNP associations and reconcile both protective and risk HLA alleles. These results implicate the nature of the HLA–viral peptide interaction as the major factor modulating durable control of HIV infection. PMID:21051598

  16. Development of intelligent MPPT (maximum power point tracking) control for a grid-connected hybrid power generation system

    International Nuclear Information System (INIS)

    Hong, Chih-Ming; Ou, Ting-Chia; Lu, Kai-Hung

    2013-01-01

    A hybrid power control system is proposed in the paper, consisting of solar power, wind power, and a diesel-engine. To achieve a fast and stable response for the real power control, an intelligent controller was proposed, which consists of the Wilcoxon (radial basis function network) RBFN and the improved (Elman neural network) ENN for (maximum power point tracking) MPPT. The pitch angle control of wind power uses improved ENN controller, and the output is fed to the wind turbine to achieve the MPPT. The solar array is integrated with an RBFN control algorithm to track the maximum power. MATLAB (MATrix LABoratory)/Simulink was used to build the dynamic model and simulate the solar and diesel-wind hybrid power system. - Highlights: ► To achieve a fast and stable response for the real power control. ► The pitch control of wind power uses improved ENN (Elman neural network) controller to achieve the MPPT (maximum power point tracking). ► The RBFN (radial basis function network) can quickly and accurately track the maximum power output for PV (photovoltaic) array. ► MATLAB was used to build the dynamic model and simulate the hybrid power system. ► This method can reach the desired performance even under different load conditions

  17. HACCP (Hazard Analysis and Critical Control Points) to guarantee safe water reuse and drinking water production--a case study.

    Science.gov (United States)

    Dewettinck, T; Van Houtte, E; Geenens, D; Van Hege, K; Verstraete, W

    2001-01-01

    To obtain a sustainable water catchment in the dune area of the Flemish west coast, the integration of treated domestic wastewater in the existing potable water production process is planned. The hygienic hazards associated with the introduction of treated domestic wastewater into the water cycle are well recognised. Therefore, the concept of HACCP (Hazard Analysis and Critical Control Points) was used to guarantee hygienically safe drinking water production. Taking into account the literature data on the removal efficiencies of the proposed advanced treatment steps with regard to enteric viruses and protozoa and after setting high quality limits based on the recent progress in quantitative risk assessment, the critical control points (CCPs) and points of attention (POAs) were identified. Based on the HACCP analysis a specific monitoring strategy was developed which focused on the control of these CCPs and POAs.

  18. Internet-based control recruitment for a case-control study of major risk factors for stroke in Korea: lessons from the experience.

    Science.gov (United States)

    Park, Jong-Moo; Cho, Yong-Jin; Lee, Kyung Bok; Park, Tai Hwan; Lee, Soo Joo; Han, Moon-Ku; Ko, Youngchai; Lee, Jun; Cha, Jae-Kwan; Lee, Byung-Chul; Yu, Kyung-Ho; Oh, Mi-Sun; Lee, Ji Sung; Lee, Juneyoung; Bae, Hee-Joon

    2014-01-01

    This study aimed to estimate the population-attributable risks (PARs) of 9 major risk factors for stroke in Korea through a case-control study and to test the feasibility and validity of internet-based control recruitment. From April 2008 to September 2009, controls were enrolled via internet after providing consent for participation through a web-based survey. The cases included patients who were admitted to the participating centers due to acute stroke or transient ischemic attack within 7 days of onset during the study period. Each control was age- and sex-matched with 2 cases. Adjusted odd ratios, age-standardized prevalence, and PARs were estimated for the 9 major risk factors using the prevalence of risk factors in the control group and the age and sex characteristics from Korea's national census data. In total, 1041 controls were matched to 2082 stroke cases. Because of a shortage of elderly controls in the internet-based recruitment, 248 controls were recruited off-line. The PARs were 23.44%, 10.95%, 51.32%, and 6.35% for hypertension, diabetes, smoking, and stroke history, respectively. Hypercholesterolemia, atrial fibrillation, obesity, coronary heart disease, and a family history of stroke were not associated with stroke. Comparison with education and religion of the control group with that mentioned in the national census data showed a notable difference. The study results imply that internet-based control recruitment for a case-control study requires careful selection of risk factors with high self-awareness and effective strategies to facilitate the recruitment of elderly participants. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  19. Age-related postoperative morphine requirements in children following major surgery--an assessment using patient-controlled analgesia (PCA)

    DEFF Research Database (Denmark)

    Hansen, Tom Giedsing; Henneberg, Steen Winther; Hole, P

    1996-01-01

    To investigate if small children require less morphine for postoperative analgesia than do older children and adolescents we analysed the morphine consumption pattern of 28 consecutive children on intravenous patient-controlled analgesia (PCA) following major surgery. The median age-specific morp......To investigate if small children require less morphine for postoperative analgesia than do older children and adolescents we analysed the morphine consumption pattern of 28 consecutive children on intravenous patient-controlled analgesia (PCA) following major surgery. The median age...

  20. Transfer from point-of-care Ultrasonography training to diagnostic performance on patients--a randomized controlled trial

    DEFF Research Database (Denmark)

    Todsen, Tobias; Jensen, Morten Lind; Tolsgaard, Martin Grønnebæk

    2016-01-01

    BACKGROUND: Clinicians are increasingly using point-of-care ultrasonography for bedside examinations of patients. However, proper training is needed in this technique, and it is unknown whether the skills learned from focused Ultrasonography courses are being transferred to diagnostic performance...... test and binary logistic regression, respectively. RESULTS: There was a significant difference in the performance score between the intervention group (27.4%) and the control group (18.0%, P = .004) and the diagnostic accuracy between the intervention group (65%) and the control group (39%, P = .014......). CONCLUSIONS: Clinicians could successfully transfer learning from an Ultrasonography course to improve diagnostic performance on patients. However, our results also indicate a need for more training when new technologies such as point-of-care ultrasonography are introduced....

  1. Design and implementation of a microcontroller-based maximum power point tracking fuzzy solar-charge controller

    Energy Technology Data Exchange (ETDEWEB)

    Qazalbash, A.A.; Iqbal, T.; Shafiq, M.Z. [National Univ. of Sciences and Technology, Rawalpindi (Pakistan). Dept. of Electrical Engineering

    2007-07-01

    Photovoltaic (PV) solar arrays are particularly useful for electrical power generation in remote, off-grid areas in developing countries. However, PV arrays offer a small power to area ratio, resulting in the need for more PV arrays which increases the cost of the system. In order to improve the profitability of PV arrays, the power extraction from available PV array systems must be maximized. This paper presented an analysis, modeling and implementation of an efficient solar charge controller. It was shown that the maximum power of a photovoltaic system depends largely on temperature and insolation. A perturb and observe algorithm was used for maximum power point tracking (MPPT). MPPT maximizes the efficiency of a solar PV system. A solar charge controller determines the optimal values of output current and voltage of converters to maximize power output for battery charging. In order to improve performance and implement the perturb and observe algorithm, the authors designed a fuzzy rule-based system in which a solar charge controller worked with a PWM controlled DC-DC converter for battery charging. The system was implemented on a low-cost PIC microcontroller. Results were better than conventional techniques in power efficiency. Swift maximum power point tracking was obtained. 13 refs., 1 tab., 11 figs.

  2. [Sickness absence associated with major life events].

    Science.gov (United States)

    Markussen, Simen; Røgeberg, Ole

    2012-05-29

    Sickness absence in the Norwegian workplace doubled in the period 1993-2003. However, the extent to which the driving factors were medical or non-medical remains unclear, as does the extent to which the cause may be found in the composition of the workforce. A differences-in-differences regression model was used to estimate the added sickness absence associated with major life events such as separation, death of spouse and pregnancy in the period 1993-2005. The data were obtained from administrative registers covering the entire Norwegian population, and include all absence periods of 16 days' duration or more reported by a doctor's medical certificate. The primary outcome measures were incidence (the proportion of absentees in a given time window) and absence (the proportion of sick days in a given time window). The level of absence among employees exposed to the specified life events was compared to control groups matched for gender, age, education and income. In 1993, people in each of the three groups exposed to major life events had more frequent and longer periods of absence than people in the control groups. This added sickness absence increased between 1993 and 2005. The changes in added sickness absence were at times significant, particularly for pregnant women. While sickness absence among pregnant women in 1993 was 15.4 percentage points higher than in the control group, the difference had increased to 24.8 percentage points in 2005. We find it improbable for the increase in added sickness absence to be caused by changes in the medical impact of life events or alterations in the workforce composition. We believe the increase is caused by changing attitudes among the working population and in the medical profession towards sickness absence on grounds that are not strictly medical, combined with improved social acceptance and diagnosis of mental health issues, and/or a medicalisation of natural health variations (pregnancy) and emotional distress (grief).

  3. The Rio Orinoco and the haven - two major cases from a legal point of view

    International Nuclear Information System (INIS)

    Jacobsson, M.

    1993-01-01

    The International Oil Pollution Compensation Fund (IOPC Fund), an inter-governmental organization with 49 member states, has recently been involved in two major oil spills of great interest from both a legal and a technical point of view. The Rio Orinoco incident occurred in Canada and the Haven incident took place in Italy. The Rio Orinoco was carrying asphalt when it grounded in the Gulf of St Lawrence. The grounding led to extensive salvage and cleanup operations carried out on behalf of the Canadian authorities. The claims for compensation, totalling 15 million Canadian dollars (12.5 million US dollars), were settled out of court. This paper discusses the main legal problems that arose, for example, the reasonableness of certain operations and the relationship between pollution prevention and salvage. The Haven exploded off Genoa with 144,000 metric tons of crude oil on board. A large quantity of oil escaped, necessitating extensive cleanup operations in Italy, France, and Monaco. Over 1,300 claims for compensation have been submitted totalling US$1.4 billion. This paper deals with some of the main legal problems that have arisen as a result of this incident, for example, the admissibility of claims relating to non-economic damage to the marine environment and the method to be applied for the conversion of the maximum amount payable by the IOPC Fund into Italian lire

  4. Equilibrium-point control of human elbow-joint movement under isometric environment by using multichannel functional electrical stimulation

    Directory of Open Access Journals (Sweden)

    Kazuhiro eMatsui

    2014-06-01

    Full Text Available Functional electrical stimulation (FES is considered an effective technique for aiding quadriplegic persons. However, the human musculoskeletal system has highly nonlinearity and redundancy. It is thus difficult to stably and accurately control limbs using FES. In this paper, we propose a simple FES method that is consistent with the motion-control mechanism observed in humans. We focus on joint motion by a pair of agonist-antagonist muscles of the musculoskeletal system, and define theelectrical agonist-antagonist muscle ratio (EAA ratio and electrical agonist-antagonist muscle activity (EAA activity in light of the agonist-antagonist muscle ratio and agonist-antagonist muscle activity, respectively, to extract the equilibrium point and joint stiffness from electromyography (EMG signals. These notions, the agonist-antagonist muscle ratio and agonist-antagonist muscle activity, are based on the hypothesis that the equilibrium point and stiffness of the agonist-antagonist motion system are controlled by the central nervous system. We derived the transfer function between the input EAA ratio and force output of the end-point. We performed some experiments in an isometric environment using six subjects. This transfer-function model is expressed as a cascade-coupled dead time element and a second-order system. High-speed, high-precision, smooth control of the hand force were achieved through the agonist-antagonist muscle stimulation pattern determined by this transfer function model.

  5. Equilibrium-point control of human elbow-joint movement under isometric environment by using multichannel functional electrical stimulation.

    Science.gov (United States)

    Matsui, Kazuhiro; Hishii, Yasuo; Maegaki, Kazuya; Yamashita, Yuto; Uemura, Mitsunori; Hirai, Hiroaki; Miyazaki, Fumio

    2014-01-01

    Functional electrical stimulation (FES) is considered an effective technique for aiding quadriplegic persons. However, the human musculoskeletal system has highly non-linearity and redundancy. It is thus difficult to stably and accurately control limbs using FES. In this paper, we propose a simple FES method that is consistent with the motion-control mechanism observed in humans. We focus on joint motion by a pair of agonist-antagonist muscles of the musculoskeletal system, and define the "electrical agonist-antagonist muscle ratio (EAA ratio)" and "electrical agonist-antagonist muscle activity (EAA activity)" in light of the agonist-antagonist muscle ratio and agonist-antagonist muscle activity, respectively, to extract the equilibrium point and joint stiffness from electromyography (EMG) signals. These notions, the agonist-antagonist muscle ratio and agonist-antagonist muscle activity, are based on the hypothesis that the equilibrium point and stiffness of the agonist-antagonist motion system are controlled by the central nervous system. We derived the transfer function between the input EAA ratio and force output of the end-point. We performed some experiments in an isometric environment using six subjects. This transfer-function model is expressed as a cascade-coupled dead time element and a second-order system. High-speed, high-precision, smooth control of the hand force were achieved through the agonist-antagonist muscle stimulation pattern determined by this transfer function model.

  6. Neuro Emotional Technique for the treatment of trigger point sensitivity in chronic neck pain sufferers: A controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Pollard Henry

    2008-05-01

    Full Text Available Abstract Background Trigger points have been shown to be active in many myofascial pain syndromes. Treatment of trigger point pain and dysfunction may be explained through the mechanisms of central and peripheral paradigms. This study aimed to investigate whether the mind/body treatment of Neuro Emotional Technique (NET could significantly relieve pain sensitivity of trigger points presenting in a cohort of chronic neck pain sufferers. Methods Sixty participants presenting to a private chiropractic clinic with chronic cervical pain as their primary complaint were sequentially allocated into treatment and control groups. Participants in the treatment group received a short course of Neuro Emotional Technique that consists of muscle testing, general semantics and Traditional Chinese Medicine. The control group received a sham NET protocol. Outcome measurements included pain assessment utilizing a visual analog scale and a pressure gauge algometer. Pain sensitivity was measured at four trigger point locations: suboccipital region (S; levator scapulae region (LS; sternocleidomastoid region (SCM and temporomandibular region (TMJ. For each outcome measurement and each trigger point, we calculated the change in measurement between pre- and post- treatment. We then examined the relationships between these measurement changes and six independent variables (i.e. treatment group and the above five additional participant variables using forward stepwise General Linear Model. Results The visual analog scale (0 to 10 had an improvement of 7.6 at S, 7.2 at LS, 7.5 at SCM and 7.1 at the TMJ in the treatment group compared with no improvement of at S, and an improvement of 0.04 at LS, 0.1 at SCM and 0.1 at the TMJ point in the control group, (P Conclusion After a short course of NET treatment, measurements of visual analog scale and pressure algometer recordings of four trigger point locations in a cohort of chronic neck pain sufferers were significantly

  7. Impact of target point deviations on control and complication probabilities in stereotactic radiosurgery of AVMs and metastases

    International Nuclear Information System (INIS)

    Treuer, Harald; Kocher, Martin; Hoevels, Moritz; Hunsche, Stefan; Luyken, Klaus; Maarouf, Mohammad; Voges, Juergen; Mueller, Rolf-Peter; Sturm, Volker

    2006-01-01

    Objective: Determination of the impact of inaccuracies in the determination and setup of the target point in stereotactic radiosurgery (SRS) on the expectable complication and control probabilities. Methods: Two randomized samples of patients with arteriovenous malformation (AVM) (n = 20) and with brain metastases (n = 20) treated with SRS were formed, and the probability for complete obliteration (COP) or complete remission (CRP), the size of the 10 Gy-volume in the brain tissue (VOI10), and the probability for radiation necrosis (NTCP) were calculated. The dose-effect relations for COP and CRP were fitted to clinical data. Target point deviations were simulated through random vectors and the resulting probabilities and volumes were calculated and compared with the values of the treatment plan. Results: The decrease of the relative value of the control probabilities at 1 mm target point deviation was up to 4% for AVMs and up to 10% for metastases. At 2 mm the median decrease was 5% for AVMs and 9% for metastases. The value for the target point deviation, at which COP and CRP decreased about 0.05 in 90% of the cases, was 1.3 mm. The increase of NTCP was maximally 0.0025 per mm target point deviation for AVMs and 0.0035/mm for metastases. The maximal increase of VOI10 was 0.7 cm 3 /mm target point deviation in both patient groups. Conclusions: The upper limit for tolerable target point deviations is at 1.3 mm. If this value cannot be achieved during the system test, a supplementary safety margin should be applied for the definition of the target volume. A better accuracy level is desirable, in order to ensure optimal chances for the success of the treatment. The target point precision is less important for the minimization of the probability of radiation necroses

  8. Genetics of mechanisms controlling responses to two major pathogens in broiler and layer chickens

    DEFF Research Database (Denmark)

    Hamzic, Edin

    The objective of this thesis was to improve the understanding of molecular mechanisms controlling the response to two major pathogens, Eimeria maxima (coccidiosis) and infectious bronchitis virus (IBV), in broiler and layer chickens, respectively. Breeding for the improved response to the two...

  9. A novel approach for automatic snow depth estimation using UAV-taken images without ground control points

    Science.gov (United States)

    Mizinski, Bartlomiej; Niedzielski, Tomasz

    2017-04-01

    Recent developments in snow depth reconstruction based on remote sensing techniques include the use of photographs of snow-covered terrain taken by unmanned aerial vehicles (UAVs). There are several approaches that utilize visible-light photos (RGB) or near infrared images (NIR). The majority of the methods in question are based on reconstructing the digital surface model (DSM) of the snow-covered area with the use of the Structure-from-Motion (SfM) algorithm and the stereo-vision software. Having reconstructed the above-mentioned DSM it is straightforward to calculate the snow depth map which may be produced as a difference between the DSM of snow-covered terrain and the snow-free DSM, known as the reference surface. In order to use the aforementioned procedure, the high spatial accuracy of the two DSMs must be ensured. Traditionally, this is done using the ground control points (GCPs), either artificial or natural terrain features that are visible on aerial images, the coordinates of which are measured in the field using the Global Navigation Satellite System (GNSS) receiver by qualified personnel. The field measurements may be time-taking (GCPs must be well distributed in the study area, therefore the field experts should travel over long distances) and dangerous (the field experts may be exposed to avalanche risk or cold). Thus, there is a need to elaborate methods that enable the above-mentioned automatic snow depth map production without the use of GCPs. One of such attempts is shown in this paper which aims to present the novel method which is based on real-time processing of snow-covered and snow-free dense point clouds produced by SfM. The two stage georeferencing is proposed. The initial (low accuracy) one assigns true geographic, and subsequently projected, coordinates to the two dense point clouds, while the said initially-registered dense point clouds are matched using the iterative closest point (ICP) algorithm in the final (high accuracy) stage. The

  10. Optimization for set-points and robust model predictive control for steam generator in nuclear power plants

    International Nuclear Information System (INIS)

    Osgouee, Ahmad

    2010-01-01

    Full Text: Nuclear power plants will be needed for future energy demands, which are expected to grow at different rates around the world. Lower operating cost is one of the major benefits of nuclear power plants over fossil power plants. Also, the plant availability is a key factor to economic index of a nuclear power plant. The opportunities for building new nuclear power plants around the world will depend on the need for clean energy with zero, or minimal emissions to support healthy communities, supply reliable energy with stable prices, and issues related to global warming and climate change. Compared to other types of power plants, nuclear power plants are preferred for their numerous advantages, including low operating costs, emission free operation with no smog, no acid rain, and no effect on global warming. Economic feasibility of a nuclear power plant requires for smooth and uninterrupted plant operation during electrical power demand variations. The steam generator (SG) in a nuclear power plant plays an important role in cooling of the reactor, balancing energy between reactor and turbine and producing steam for the turbine-generators. SG acts as an additional safety barrier between the nuclear reactor and the outside world also. As a result, control of the water inventory in the SG is very important to ensure continuous cooling of the nuclear reactor core, plant protection and at the same time, to prevent the SG tubes and turbine blades failure. A review of past nuclear power plant operation experiences indicates that unplanned reactor trips due to steam generator level (SGL) control have been significant contributors to plant unavailability. During low power operation, the level control is complicated by the thermal reverse effects known as 'shrink and swell'. Manual operator intervention to the SGL control system at low reactor power and to the unit upset conditions has been identified as an operator response in most nuclear power plants. In spite of

  11. Liquid in the major incision

    International Nuclear Information System (INIS)

    Herrera Jaramillo, Diego Alberto; Ortega Jaramillo, Hector

    2003-01-01

    We present the case of a patient with spill pleural extending in the left major incision. In the chest thorax PA, we could observe one of the complex radiographic appearances that take the reconfiguration of fluid in this localization, being this appearance dependent of the patient's position. Some points are also discussed on the anatomy of the major incisions and some of their radiographic characteristics

  12. Calorimetry end-point predictions

    International Nuclear Information System (INIS)

    Fox, M.A.

    1981-01-01

    This paper describes a portion of the work presently in progress at Rocky Flats in the field of calorimetry. In particular, calorimetry end-point predictions are outlined. The problems associated with end-point predictions and the progress made in overcoming these obstacles are discussed. The two major problems, noise and an accurate description of the heat function, are dealt with to obtain the most accurate results. Data are taken from an actual calorimeter and are processed by means of three different noise reduction techniques. The processed data are then utilized by one to four algorithms, depending on the accuracy desired to determined the end-point

  13. Probabilistic safety assessment and optimal control of hazardous technological systems. A marked point process approach

    Energy Technology Data Exchange (ETDEWEB)

    Holmberg, J [VTT Automation, Espoo (Finland)

    1997-04-01

    The thesis models risk management as an optimal control problem for a stochastic process. The approach classes the decisions made by management into three categories according to the control methods of a point process: (1) planned process lifetime, (2) modification of the design, and (3) operational decisions. The approach is used for optimization of plant shutdown criteria and surveillance test strategies of a hypothetical nuclear power plant. 62 refs. The thesis includes also five previous publications by author.

  14. LiveWire interactive boundary extraction algorithm based on Haar wavelet transform and control point set direction search

    Science.gov (United States)

    Cheng, Jun; Zhang, Jun; Tian, Jinwen

    2015-12-01

    Based on deep analysis of the LiveWire interactive boundary extraction algorithm, a new algorithm focusing on improving the speed of LiveWire algorithm is proposed in this paper. Firstly, the Haar wavelet transform is carried on the input image, and the boundary is extracted on the low resolution image obtained by the wavelet transform of the input image. Secondly, calculating LiveWire shortest path is based on the control point set direction search by utilizing the spatial relationship between the two control points users provide in real time. Thirdly, the search order of the adjacent points of the starting node is set in advance. An ordinary queue instead of a priority queue is taken as the storage pool of the points when optimizing their shortest path value, thus reducing the complexity of the algorithm from O[n2] to O[n]. Finally, A region iterative backward projection method based on neighborhood pixel polling has been used to convert dual-pixel boundary of the reconstructed image to single-pixel boundary after Haar wavelet inverse transform. The algorithm proposed in this paper combines the advantage of the Haar wavelet transform and the advantage of the optimal path searching method based on control point set direction search. The former has fast speed of image decomposition and reconstruction and is more consistent with the texture features of the image and the latter can reduce the time complexity of the original algorithm. So that the algorithm can improve the speed in interactive boundary extraction as well as reflect the boundary information of the image more comprehensively. All methods mentioned above have a big role in improving the execution efficiency and the robustness of the algorithm.

  15. The Type-2 Fuzzy Logic Controller-Based Maximum Power Point Tracking Algorithm and the Quadratic Boost Converter for Pv System

    Science.gov (United States)

    Altin, Necmi

    2018-05-01

    An interval type-2 fuzzy logic controller-based maximum power point tracking algorithm and direct current-direct current (DC-DC) converter topology are proposed for photovoltaic (PV) systems. The proposed maximum power point tracking algorithm is designed based on an interval type-2 fuzzy logic controller that has an ability to handle uncertainties. The change in PV power and the change in PV voltage are determined as inputs of the proposed controller, while the change in duty cycle is determined as the output of the controller. Seven interval type-2 fuzzy sets are determined and used as membership functions for input and output variables. The quadratic boost converter provides high voltage step-up ability without any reduction in performance and stability of the system. The performance of the proposed system is validated through MATLAB/Simulink simulations. It is seen that the proposed system provides high maximum power point tracking speed and accuracy even for fast changing atmospheric conditions and high voltage step-up requirements.

  16. Elevated serum levels of malondialdehyde and cortisol are associated with major depressive disorder: A case-control study

    Science.gov (United States)

    Islam, Md Reazul; Ahmed, Imtiaz; Moktadir, Abdullah Al; Nahar, Zabun; Islam, Mohammad Safiqul; Shahid, Shelina Fatema Binte; Islam, Sheikh Nazrul; Islam, Md Saiful; Hasnat, Abul

    2018-01-01

    Objectives: Major depressive disorder is diagnosed on the basis of patient’s self-reported experiences, behavior reported by relatives, and a mental status examination, and yet we do not have any reliable biomarker for this. Mood-regulating pathways are affected by oxidative injury to lipids and cortisol is released into the blood due to stimulation of corticotrophin receptors in the adrenal cortex. Here, we aimed to determine serum levels of malondialdehyde and cortisol in major depressive disorder patients and controls. Methods: We collected blood samples from 247 major depressive disorder patients and 248 controls. Serum levels of malondialdehyde and cortisol were measured by ultraviolet spectrophotometry and enzyme-linked immunosorbent assay kit, respectively. Results: We found malondialdehyde levels were significantly higher in patients than controls, with mean ± standard deviation at 4.49 ± 1.37 and 2.87 ± 0.82 µmol/L, respectively, p < 0.001. Cortisol levels were also found significantly higher in patients than controls, with mean ± SD at 19.22 ± 1.64 and 17.37 ± 1.34 µg/dL, respectively, p < 0.001. Significant negative correlation was observed between serum levels of malondialdehyde and cortisol in patients (r =−0.170, p = 0.021). Receiver operating characteristic analysis showed good diagnostic value for malondialdehyde and cortisol, with the area under the curve at 0.853 and 0.819, respectively. Conclusion: The present study suggests that increased serum levels of malondialdehyde and cortisol are strongly associated with major depressive disorder. We believe elevations of malondialdehyde and cortisol in serum level arise independently and they could serve as biomarkers for major depressive disorder. PMID:29770218

  17. Inherently safe SNR shutdown system with Curie point controlled sensor/switch unit

    International Nuclear Information System (INIS)

    Mueller, K.; Norajitra, P.; Reiser, H.

    1987-02-01

    Inherent shutdown due to increase in the sodium temperature at the core outlet is triggered by interruption of the current supply to the electromagnet coupling of absorber elements via curie point controlled sensor/switch units. These switches are arranged above suitable fuel element positions and spatially independent of the shutdown elements. Compared with other similar systems very short response times are achieved. A prototype switch unit has already undergone extensive testing. These tests have confirmed that switching takes place in a very narrow temperature range. (orig./HP) [de

  18. Changes in cytokine and chemokine expression distinguish dysthymic disorder from major depression and healthy controls.

    Science.gov (United States)

    Ho, Pei-Shen; Yen, Che-Hung; Chen, Chun-Yen; Huang, San-Yuan; Liang, Chih-Sung

    2017-02-01

    An important area of uncertainty is the inflammatory degree to which depression occurring as part of dysthymic disorder may differ from major depression. Using a 27-plex cytokine assay, we analyzed the serum of 12 patients with dysthymic disorder, 12 with major depression, and an age-, sex-, and body mass index-matched control group of 20 healthy volunteers. We observed that patients with dysthymic disorder exhibited aberrant cytokine and chemokine expression compared with healthy controls and patients with major depression. The levels of interferon-γ-induced protein 10 highly predicted dysthymic disorder. Network analyses revealed that in patients with dysthymic disorder, the vertices were more sparsely connected and adopted a more hub-like architecture, and the connections from neighboring vertices of interleukin 2 and eotaxin-1 increased. After treatment with the same antidepressant, there was no difference between dysthymic disorder and major depression regarding any of the cytokines or chemokines analyzed. For dysthymic disorder, changes in the levels of interferon-γ-induced protein 10 and macrophage inflammatory protein-1α correlated with depression improvement. The findings suggest that the cytokine milieu in dysthymic disorder differs either at the level of individual expression or in network patterns. Moreover, chemokines play an important role in driving the pathophysiology of dysthymic disorder. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Early cryoprecipitate for major haemorrhage in trauma: a randomised controlled feasibility trial.

    Science.gov (United States)

    Curry, N; Rourke, C; Davenport, R; Beer, S; Pankhurst, L; Deary, A; Thomas, H; Llewelyn, C; Green, L; Doughty, H; Nordmann, G; Brohi, K; Stanworth, S

    2015-07-01

    Low fibrinogen (Fg) concentrations in trauma haemorrhage are associated with poorer outcomes. Cryoprecipitate is the standard source for Fg administration in the UK and USA and is often given in the later stages of transfusion therapy. It is not known whether early cryoprecipitate therapy improves clinical outcomes. The primary aim of this feasibility study was to determine whether it was possible to administer cryoprecipitate, within 90 min of admission to hospital. Secondary aims were to evaluate laboratory measures of Fg and clinical outcomes including thrombotic events, organ failure, length of hospital stay and mortality. This was an unblinded RCT, conducted at two civilian UK major trauma centres of adult trauma patients (age ≥16 yrs), with active bleeding and requiring activation of the major haemorrhage protocol. Participants were randomised to standard major haemorrhage therapy (STANDARD) (n=22), or to standard haemorrhage therapy plus two early pools of cryoprecipitate (CRYO) (n=21). 85% (95% CI: 69-100%) CRYO participants received cryoprecipitate within 90 min, median time 60 min (IQR: 57-76) compared with 108 min (67-147), CRYO and STANDARD arms respectively (P=0.002). Fg concentrations were higher in the CRYO arm and were maintained above 1.8 g litre(-1) at all time-points during active haemorrhage. All-cause mortality at 28 days was not significantly different (P=0.14). Early Fg supplementation using cryoprecipitate is feasible in trauma patients. This study supports the need for a definitive RCT to determine the effect of early Fg supplementation on mortality and other clinical outcomes. ISRCTN55509212. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. A maximum power point tracking for photovoltaic-SPE system using a maximum current controller

    Energy Technology Data Exchange (ETDEWEB)

    Muhida, Riza [Osaka Univ., Dept. of Physical Science, Toyonaka, Osaka (Japan); Osaka Univ., Dept. of Electrical Engineering, Suita, Osaka (Japan); Park, Minwon; Dakkak, Mohammed; Matsuura, Kenji [Osaka Univ., Dept. of Electrical Engineering, Suita, Osaka (Japan); Tsuyoshi, Akira; Michira, Masakazu [Kobe City College of Technology, Nishi-ku, Kobe (Japan)

    2003-02-01

    Processes to produce hydrogen from solar photovoltaic (PV)-powered water electrolysis using solid polymer electrolysis (SPE) are reported. An alternative control of maximum power point tracking (MPPT) in the PV-SPE system based on the maximum current searching methods has been designed and implemented. Based on the characteristics of voltage-current and theoretical analysis of SPE, it can be shown that the tracking of the maximum current output of DC-DC converter in SPE side will track the MPPT of photovoltaic panel simultaneously. This method uses a proportional integrator controller to control the duty factor of DC-DC converter with pulse-width modulator (PWM). The MPPT performance and hydrogen production performance of this method have been evaluated and discussed based on the results of the experiment. (Author)

  1. [The different point of view about the sanitary control of importation of psychotropic substances in Brazil].

    Science.gov (United States)

    Sebastião, Patrícia Cristina Antunes; Lucchese, Geraldo

    2010-11-01

    The purpose of this work is to analyze the process of importation, that is a part of the sanitary control of psychotropic substances, made by Brazilian National Health Surveillance Agency's ports, airports and borders. For this work, psychotropic substances are defined as active pharmaceutical raw materials present in the list B1 of Portaria nº 344/98; which need Anvisa's permission to be imported. For this purpose we used semistructured interviews with key informers and participant observation. The information were collected and systematized through the content analysis, thematic modality. The results show a very complex control which involves an intense bureaucratic process. The main identified critical points of the process were: the information system precariousness; the absence of human resources; deficiency of laboratorial support and infra-structure at customs. Anvisa's web page and the specific law are strong points of the process, but still needing improvements. We understood that despite of the progress made, there are many things to do for giving the country an efficient health control system to the importation of these substances.

  2. 40 CFR 63.1583 - What are the emission points and control requirements for an industrial POTW treatment plant?

    Science.gov (United States)

    2010-07-01

    ... control requirements for an industrial POTW treatment plant? 63.1583 Section 63.1583 Protection of... Pollutants: Publicly Owned Treatment Works Industrial Potw Treatment Plant Description and Requirements § 63.1583 What are the emission points and control requirements for an industrial POTW treatment plant? (a...

  3. A Globally Stable Lyapunov Pointing and Rate Controller for the Magnetospheric MultiScale Mission (MMS)

    Science.gov (United States)

    Shah, Neerav

    2011-01-01

    The Magnetospheric MultiScale Mission (MMS) is scheduled to launch in late 2014. Its primary goal is to discover the fundamental plasma physics processes of reconnection in the Earth's magnetosphere. Each of the four MMS spacecraft is spin-stabilized at a nominal rate of 3 RPM. Traditional spin-stabilized spacecraft have used a number of separate modes to control nutation, spin rate, and precession. To reduce the number of modes and simplify operations, the Delta-H control mode is designed to accomplish nutation control, spin rate control, and precession control simultaneously. A nonlinear design technique, Lyapunov's method, is used to design the Delta-H control mode. A global spin rate controller selected as the baseline controller for MMS, proved to be insufficient due to an ambiguity in the attitude. Lyapunov's design method was used to solve this ambiguity, resulting in a controller that meets the design goals. Simulation results show the advantage of the pointing and rate controller for maneuvers larger than 90 deg and provide insight into the performance of this controller.

  4. Design and control of a point absorber wave energy converter with an open loop hydraulic transmission

    International Nuclear Information System (INIS)

    Fan, YaJun; Mu, AnLe; Ma, Tao

    2016-01-01

    Highlights: • Point absorber wave energy converter is presented. • Piston pump module captures and converts wave energy. • Hydraulic accumulator stores/releases the surplus energy. • Fuzzy controller adjusts the displacement of hydraulic motor. • Generator outputs meet the electricity demand precisely. - Abstract: In this paper, a point absorber wave energy converter combined with offshore wind turbine is proposed. In the system, the wave energy is captured and converted into hydraulic energy by a piston pump module, which is combined with a wind turbine floating platform, and then the hydraulic energy is converted into electricity energy by a variable displacement hydraulic motor and induction generator. In order to smooth and stabilize the captured wave energy, a hydraulic accumulator is applied to store and release the excess energy. In order to meet the demand power a fuzzy controller is designed to adjust the displacement of hydraulic motor and controlled the output power. Simulation under irregular wave condition has been carried out to verify the validity of the mathematical model and the effectiveness of the controller strategy. The results show that the wave energy converter system could deliver the required electricity power precisely as the motor output torque is controlled. The accumulator could damp out all the fluctuations in output power, so the wave energy would become a dispatchable power source.

  5. Genetic algorithms optimized fuzzy logic control for the maximum power point tracking in photovoltaic system

    Energy Technology Data Exchange (ETDEWEB)

    Larbes, C.; Ait Cheikh, S.M.; Obeidi, T.; Zerguerras, A. [Laboratoire des Dispositifs de Communication et de Conversion Photovoltaique, Departement d' Electronique, Ecole Nationale Polytechnique, 10, Avenue Hassen Badi, El Harrach, Alger 16200 (Algeria)

    2009-10-15

    This paper presents an intelligent control method for the maximum power point tracking (MPPT) of a photovoltaic system under variable temperature and irradiance conditions. First, for the purpose of comparison and because of its proven and good performances, the perturbation and observation (P and O) technique is briefly introduced. A fuzzy logic controller based MPPT (FLC) is then proposed which has shown better performances compared to the P and O MPPT based approach. The proposed FLC has been also improved using genetic algorithms (GA) for optimisation. Different development stages are presented and the optimized fuzzy logic MPPT controller (OFLC) is then simulated and evaluated, which has shown better performances. (author)

  6. Towards free 3D end-point control for robotic-assisted human reaching using binocular eye tracking.

    Science.gov (United States)

    Maimon-Dror, Roni O; Fernandez-Quesada, Jorge; Zito, Giuseppe A; Konnaris, Charalambos; Dziemian, Sabine; Faisal, A Aldo

    2017-07-01

    Eye-movements are the only directly observable behavioural signals that are highly correlated with actions at the task level, and proactive of body movements and thus reflect action intentions. Moreover, eye movements are preserved in many movement disorders leading to paralysis (or amputees) from stroke, spinal cord injury, Parkinson's disease, multiple sclerosis, and muscular dystrophy among others. Despite this benefit, eye tracking is not widely used as control interface for robotic interfaces in movement impaired patients due to poor human-robot interfaces. We demonstrate here how combining 3D gaze tracking using our GT3D binocular eye tracker with custom designed 3D head tracking system and calibration method enables continuous 3D end-point control of a robotic arm support system. The users can move their own hand to any location of the workspace by simple looking at the target and winking once. This purely eye tracking based system enables the end-user to retain free head movement and yet achieves high spatial end point accuracy in the order of 6 cm RMSE error in each dimension and standard deviation of 4 cm. 3D calibration is achieved by moving the robot along a 3 dimensional space filling Peano curve while the user is tracking it with their eyes. This results in a fully automated calibration procedure that yields several thousand calibration points versus standard approaches using a dozen points, resulting in beyond state-of-the-art 3D accuracy and precision.

  7. The role of controlled attention on recall in major depression.

    Science.gov (United States)

    Ellis, Alissa J; Wells, Tony T; Vanderlind, W Michael; Beevers, Christopher G

    2014-04-01

    Information processing biases are hallmark features of major depressive disorder (MDD). Depressed individuals display biased memory and attention for negative material. Given that memory is highly dependent on attention for initial encoding, understanding the interplay of these processes may provide important insight into mechanisms that produce memory biases in depression. In particular, attentional control-the ability to selectively attend to task-relevant information by both inhibiting the processing of irrelevant information and disengaging attention from irrelevant material-may be one area of impairment in MDD. In the current study, clinically depressed (MDD: n = 15) and never depressed (non-MDD: n = 22) participants' line of visual gaze was assessed while participants viewed positive and negative word pairs. For each word pair, participants were instructed to attend to one word (target) and ignore one word (distracter). Free recall of study stimuli was then assessed. Depressed individuals displayed greater recall of negatively valenced target words following the task. Although there were no group differences in attentional control in the context of negative words, attention to negative targets mediated the relationship between depression status and recall of negative words. Results suggest a stronger link between attention and memory for negative material in MDD.

  8. Thermoplastic fusion bonding using a pressure-assisted boiling point control system.

    Science.gov (United States)

    Park, Taehyun; Song, In-Hyouk; Park, Daniel S; You, Byoung Hee; Murphy, Michael C

    2012-08-21

    A novel thermoplastic fusion bonding method using a pressure-assisted boiling point (PABP) control system was developed to apply precise temperatures and pressures during bonding. Hot embossed polymethyl methacrylate (PMMA) components containing microchannels were sealed using the PABP system. Very low aspect ratio structures (AR = 1/100, 10 μm in depth and 1000 μm in width) were successfully sealed without collapse or deformation. The integrity and strength of the bonds on the sealed PMMA devices were evaluated using leakage and rupture tests; no leaks were detected and failure during the rupture tests occurred at pressures greater than 496 kPa. The PABP system was used to seal 3D shaped flexible PMMA devices successfully.

  9. Headache: an important factor associated with muscle soreness/pain at the two-year follow-up point among patients with major depressive disorder.

    Science.gov (United States)

    Hung, Ching-I; Liu, Chia-Yih; Yang, Ching-Hui; Wang, Shuu-Jiun

    2016-01-01

    No study has compared the associations of headache, anxiety, and depression at baseline with muscle soreness or pain (MS/P) at baseline and at the two-year follow-up point among outpatients with major depressive disorder (MDD). This study aimed to investigate the above issue. This study enrolled 155 outpatients with MDD at baseline, and 131 attended a two-year follow-up appointment. At baseline, migraine was diagnosed based on the International Classification of Headache Disorders, 2(nd) edition. MDD and anxiety disorders were diagnosed using the Structured Clinical Interview for DSM-IV-TR. The visual analog scale was used to evaluate the intensities of headache and MS/P in the neck, shoulder, back, upper limbs, and lower limbs. Depression and anxiety were evaluated using the Hospital Anxiety and Depression Scale. Multiple linear regressions were used to compare the associations of these factors with MS/P. Compared with anxiety disorders, migraine was more strongly associated with MS/P in all areas at baseline and in the upper and lower limbs at follow-up. Headache intensity at baseline was the factor most strongly associated with MS/P in all areas at baseline and follow-up after controlling for depression and anxiety. Headache intensity at baseline predicted MS/P at baseline and follow-up. Migraine and headache intensity are important factors related to MS/P at baseline and follow-up among patients with MDD. Integrating depression and headache treatment might be indicated to improve MS/P.

  10. Analysis of risk factors from salmonella infections and determination of critical control points in poultry industry production chain

    Directory of Open Access Journals (Sweden)

    Velhner Maja

    2005-01-01

    Full Text Available This paper encompasses problems related to infection caused by Salmonella spp in poultry. The need to carry out adequate control measures and to provide safe food is emphasized. Using experiences from other countries, critical control points are presented in flocks during rearing and in hatcheries. In attempt to diagnose disease as early as possible and to advise proper therapy, the significance of serology monitoring is underlined. In order to produce safe food there is a need to control disease applying our Regulations concerning eradication of Salmonella spp in poultry flocks that is given in Official paper of Republic of Serbia No 6&88 and also to include serology monitoring in poultry flocks. Veterinary practitioners are expected to perform analysis of critical control points in poultry industry as well as to determine specificity and differences in production for single farms, which would enable more effective struggle with diseases in general.

  11. Does the European natural gas market pass the competitive benchmark of the theory of storage? Indirect tests for three major trading points

    International Nuclear Information System (INIS)

    Stronzik, Marcus; Rammerstorfer, Margarethe; Neumann, Anne

    2009-01-01

    This paper presents the first comparative analysis of the relationship between natural gas storage utilization and price patterns at three major European trading points. Using two indirect tests developed by that are applied in other commodity markets, we impose the no arbitrage condition to model the efficiency of the natural gas market. The results reveal that while operators of European storage facilities realize seasonal arbitrage profits, substantial arbitrage potentials remain. We suggest that the indirect approach is well suited to provide market insights for periods with limited data. We find that overall market performance differs substantially from the competitive benchmark of the theory of storage. (author)

  12. Maximum Power Point Tracking Control of a Thermoelectric Generation System Using the Extremum Seeking Control Method

    Directory of Open Access Journals (Sweden)

    Ssennoga Twaha

    2017-12-01

    Full Text Available This study proposes and implements maximum power Point Tracking (MPPT control on thermoelectric generation system using an extremum seeking control (ESC algorithm. The MPPT is applied to guarantee maximum power extraction from the TEG system. The work has been carried out through modelling of thermoelectric generator/dc-dc converter system using Matlab/Simulink. The effectiveness of ESC technique has been assessed by comparing the results with those of the Perturb and Observe (P&O MPPT method under the same operating conditions. Results indicate that ESC MPPT method extracts more power than the P&O technique, where the output power of ESC technique is higher than that of P&O by 0.47 W or 6.1% at a hot side temperature of 200 °C. It is also noted that the ESC MPPT based model is almost fourfold faster than the P&O method. This is attributed to smaller MPPT circuit of ESC compared to that of P&O, hence we conclude that the ESC MPPT method outperforms the P&O technique.

  13. Design of the control system for fixed-point keeping in FPSO (Floating Production Storage and Offloading); FPSO no teiten hoji no tame no seigyokei no sekkei ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Kijima, K; Murata, W; Furukawa, Y [Kyushu University, Fukuoka (Japan). Faculty of Engineering

    1997-10-01

    The control system for keeping the fixed-point of ships against disturbance was designed by applying an ILQ (Inverse Linear Quadratic) control (possible to specify the response of controlled systems with time constant) theory, to study the effect of different time constants as design parameter on a fixed-point keeping performance. It was assumed that the controlled ship is equipped with two bow thrusters and one stern thruster of 30ton in output to generate a control force. For fixed-point keeping control, the state equation was derived to slave the controlled system to a target input. The ILQ design method uses the result of the inverse problem of optimum regulators. For designing control systems by using the ILQ control theory, the smallest time constant should be selected according to the most severe disturbance condition considering the response performance of controllers, to achieve fixed-point keeping of ships. In fixed-point keeping, it is also essential to put the initial position as close as possible to the target point. 2 refs., 6 figs., 2 tabs.

  14. A Comparative Study of Applying Active-Set and Interior Point Methods in MPC for Controlling Nonlinear pH Process

    Directory of Open Access Journals (Sweden)

    Syam Syafiie

    2014-06-01

    Full Text Available A comparative study of Model Predictive Control (MPC using active-set method and interior point methods is proposed as a control technique for highly non-linear pH process. The process is a strong acid-strong base system. A strong acid of hydrochloric acid (HCl and a strong base of sodium hydroxide (NaOH with the presence of buffer solution sodium bicarbonate (NaHCO3 are used in a neutralization process flowing into reactor. The non-linear pH neutralization model governed in this process is presented by multi-linear models. Performance of both controllers is studied by evaluating its ability of set-point tracking and disturbance-rejection. Besides, the optimization time is compared between these two methods; both MPC shows the similar performance with no overshoot, offset, and oscillation. However, the conventional active-set method gives a shorter control action time for small scale optimization problem compared to MPC using IPM method for pH control.

  15. Point specificity in acupuncture

    Directory of Open Access Journals (Sweden)

    Choi Emma M

    2012-02-01

    Full Text Available Abstract The existence of point specificity in acupuncture is controversial, because many acupuncture studies using this principle to select control points have found that sham acupoints have similar effects to those of verum acupoints. Furthermore, the results of pain-related studies based on visual analogue scales have not supported the concept of point specificity. In contrast, hemodynamic, functional magnetic resonance imaging and neurophysiological studies evaluating the responses to stimulation of multiple points on the body surface have shown that point-specific actions are present. This review article focuses on clinical and laboratory studies supporting the existence of point specificity in acupuncture and also addresses studies that do not support this concept. Further research is needed to elucidate the point-specific actions of acupuncture.

  16. Propofol clearance and volume of distribution are increased in patients with major burns.

    Science.gov (United States)

    Han, Tae-Hyung; Greenblatt, David J; Martyn, J A Jeevendra

    2009-07-01

    Propofol pharmacokinetics were examined in 17 adults with major burns during the hyperdynamic convalescent phase. Eighteen nonburned surgical patients served as controls. After a 2-mg/kg intravenous dose of propofol, blood samples were collected at multiple time points. Noncompartmental methods were used to calculate the pharmacokinetic parameters. The following indices were higher in burns than controls: propofol clearance (64+/-17 vs 29+/-4 mL/kg/min, Pclearance of propofol in burned patients may imply that these patients require higher doses or infusion rates of propofol to attain a target plasma concentration or pharmacodynamic effect.

  17. Antenna Controller Replacement Software

    Science.gov (United States)

    Chao, Roger Y.; Morgan, Scott C.; Strain, Martha M.; Rockwell, Stephen T.; Shimizu, Kenneth J.; Tehrani, Barzia J.; Kwok, Jaclyn H.; Tuazon-Wong, Michelle; Valtier, Henry; Nalbandi, Reza; hide

    2010-01-01

    The Antenna Controller Replacement (ACR) software accurately points and monitors the Deep Space Network (DSN) 70-m and 34-m high-efficiency (HEF) ground-based antennas that are used to track primarily spacecraft and, periodically, celestial targets. To track a spacecraft, or other targets, the antenna must be accurately pointed at the spacecraft, which can be very far away with very weak signals. ACR s conical scanning capability collects the signal in a circular pattern around the target, calculates the location of the strongest signal, and adjusts the antenna pointing to point directly at the spacecraft. A real-time, closed-loop servo control algorithm performed every 0.02 second allows accurate positioning of the antenna in order to track these distant spacecraft. Additionally, this advanced servo control algorithm provides better antenna pointing performance in windy conditions. The ACR software provides high-level commands that provide a very easy user interface for the DSN operator. The operator only needs to enter two commands to start the antenna and subreflector, and Master Equatorial tracking. The most accurate antenna pointing is accomplished by aligning the antenna to the Master Equatorial, which because of its small size and sheltered location, has the most stable pointing. The antenna has hundreds of digital and analog monitor points. The ACR software provides compact displays to summarize the status of the antenna, subreflector, and the Master Equatorial. The ACR software has two major functions. First, it performs all of the steps required to accurately point the antenna (and subreflector and Master Equatorial) at the spacecraft (or celestial target). This involves controlling the antenna/ subreflector/Master-Equatorial hardware, initiating and monitoring the correct sequence of operations, calculating the position of the spacecraft relative to the antenna, executing the real-time servo control algorithm to maintain the correct position, and

  18. Impact of point A asymmetry on local control and survival for low dose-rate (LDR) brachytherapy in cervical cancer.

    Science.gov (United States)

    Opfermann, Krisha J; Wahlquist, Amy; Watkins, John; Kohler, Matthew; Jenrette, Joseph

    2012-03-01

    To evaluate whether Point A asymmetry in low dose-rate (LDR) brachytherapy is associated with local control (LC), disease-free survival (DFS) and/or overall survival (OS). A retrospective analysis of disease control and survival outcomes was conducted for patients who underwent LDR brachytherapy for advanced cervical cancer. Institutional protocol entailed concurrent chemotherapy and whole pelvis radiotherapy (WPRT) over 5 weeks, followed by placement of Fletcher-Suit tandem and colpostat applicators at weeks 6 and 8. Objective Point A doses, 80-85 Gy, were accomplished by placement of Cesium-137 (Cs-137) sources. Cox proportional hazards regression models were used to assess associations between disease control and survival endpoints with variables of interest. The records of 50 patients with FIGO stage IB1-IVA cervical cancer undergoing LDR brachytherapy at our institution were identified. Thirty of these patients had asymmetry > 2.5%, and 11 patients had asymmetry > 5%. At a median survivor follow-up of 20.25 months, 15 patients had experienced disease failure (including 5 cervical/vaginal apex only failures and 2 failures encompassing the local site). Right/left dose asymmetry at Point A was associated with statistically significantly inferior LC (p = 0.035) and inferior DFS (p = 0.011) for patients with mean Point A dose of > 80 Gy. Insufficient evidence existed to conclude an association with OS. LDR brachytherapy may be associated with clinically significant dose asymmetry. The present study demonstrates that patients with Point A asymmetry have a higher risk of failure for DFS and LC.

  19. Robust maximum power point tracker using sliding mode controller for the three-phase grid-connected photovoltaic system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Il-Song [LG Chem. Ltd./Research park, Mobile Energy R and D, 104-1 Moonji-Dong, Yuseong-Gu, Daejeon 305-380 (Korea)

    2007-03-15

    A robust maximum power point tracker (MPPT) using sliding mode controller for the three-phase grid-connected photovoltaic system has been proposed in this paper. Contrary to the previous controller, the proposed system consists of MPPT controller and current controller for tight regulation of the current. The proposed MPPT controller generates current reference directly from the solar array power information and the current controller uses the integral sliding mode for the tight control of current. The proposed system can prevent the current overshoot and provide optimal design for the system components. The structure of the proposed system is simple, and it shows robust tracking property against modeling uncertainties and parameter variations. Mathematical modeling is developed and the experimental results verify the validity of the proposed controller. (author)

  20. Maximum Power Point Tracking in Variable Speed Wind Turbine Based on Permanent Magnet Synchronous Generator Using Maximum Torque Sliding Mode Control Strategy

    Institute of Scientific and Technical Information of China (English)

    Esmaeil Ghaderi; Hossein Tohidi; Behnam Khosrozadeh

    2017-01-01

    The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy.In this strategy,fhst,the rotor speed is set at an optimal point for different wind speeds.As a result of which,the tip speed ratio reaches an optimal point,mechanical power coefficient is maximized,and wind turbine produces its maximum power and mechanical torque.Then,the maximum mechanical torque is tracked using electromechanical torque.In this technique,tracking error integral of maximum mechanical torque,the error,and the derivative of error are used as state variables.During changes in wind speed,sliding mode control is designed to absorb the maximum energy from the wind and minimize the response time of maximum power point tracking (MPPT).In this method,the actual control input signal is formed from a second order integral operation of the original sliding mode control input signal.The result of the second order integral in this model includes control signal integrity,full chattering attenuation,and prevention from large fluctuations in the power generator output.The simulation results,calculated by using MATLAB/m-file software,have shown the effectiveness of the proposed control strategy for wind energy systems based on the permanent magnet synchronous generator (PMSG).

  1. Teacher points to dyslexia as a major cause of school failure

    Directory of Open Access Journals (Sweden)

    Vicente Martins

    2002-01-01

    Full Text Available In the past seven years, Professor Vincent Martins has developed studies on the contribution of linguistics to the diagnosis of dyslexia. The dyslexia is a disturbance or inconvenience to the level of reading. The dyslexic children is a bad player: you can read but can not effectively understand what you read. The estimate of the teacher is that, in Brazil at least 15 million children and young people suffering with disorders of letters. For the teacher, the dyslexia is the major cause of low school performance.

  2. Efficacy and safety of deep transcranial magnetic stimulation for major depression: a prospective multicenter randomized controlled trial.

    Science.gov (United States)

    Levkovitz, Yechiel; Isserles, Moshe; Padberg, Frank; Lisanby, Sarah H; Bystritsky, Alexander; Xia, Guohua; Tendler, Aron; Daskalakis, Zafiris J; Winston, Jaron L; Dannon, Pinhas; Hafez, Hisham M; Reti, Irving M; Morales, Oscar G; Schlaepfer, Thomas E; Hollander, Eric; Berman, Joshua A; Husain, Mustafa M; Sofer, Uzi; Stein, Ahava; Adler, Shmulik; Deutsch, Lisa; Deutsch, Frederic; Roth, Yiftach; George, Mark S; Zangen, Abraham

    2015-02-01

    Major depressive disorder (MDD) is a prevalent and disabling condition, and many patients do not respond to available treatments. Deep transcranial magnetic stimulation (dTMS) is a new technology allowing non-surgical stimulation of relatively deep brain areas. This is the first double-blind randomized controlled multicenter study evaluating the efficacy and safety of dTMS in MDD. We recruited 212 MDD outpatients, aged 22-68 years, who had either failed one to four antidepressant trials or not tolerated at least two antidepressant treatments during the current episode. They were randomly assigned to monotherapy with active or sham dTMS. Twenty sessions of dTMS (18 Hz over the prefrontal cortex) were applied during 4 weeks acutely, and then biweekly for 12 weeks. Primary and secondary efficacy endpoints were the change in the Hamilton Depression Rating Scale (HDRS-21) score and response/remission rates at week 5, respectively. dTMS induced a 6.39 point improvement in HDRS-21 scores, while a 3.28 point improvement was observed in the sham group (p=0.008), resulting in a 0.76 effect size. Response and remission rates were higher in the dTMS than in the sham group (response: 38.4 vs. 21.4%, p=0.013; remission: 32.6 vs. 14.6%, p=0.005). These differences between active and sham treatment were stable during the 12-week maintenance phase. dTMS was associated with few and minor side effects apart from one seizure in a patient where a protocol violation occurred. These results suggest that dTMS constitutes a novel intervention in MDD, which is efficacious and safe in patients not responding to antidepressant medications, and whose effect remains stable over 3 months of maintenance treatment. © 2015 World Psychiatric Association.

  3. Efficacy and Effectiveness of Exercise on Tender Points in Adults with Fibromyalgia: A Meta-Analysis of Randomized Controlled Trials

    Directory of Open Access Journals (Sweden)

    George A. Kelley

    2011-01-01

    Full Text Available Fibromyalgia is a major public health problem affecting an estimated 200 to 400 million people worldwide. The purpose of this study was to use the meta-analytic approach to determine the efficacy and effectiveness of randomized controlled exercise intervention trials (aerobic, strength training, or both on tender points (TPs in adults with fibromyalgia. Using random effects models and 95% confidence intervals (CI, a statistically significant reduction in TPs was observed based on per-protocol analyses (8 studies representing 322 participants but not intention-to-treat analyses (5 studies representing 338 participants (per-protocol, , −0.68, 95% CI, −1.16, −0.20; intention-to-treat, , −0.24, 95% CI, −0.62, 0.15. Changes were equivalent to relative reductions of 10.9% and 6.9%, respectively, for per-protocol and intention-to-treat analyses. It was concluded that exercise is efficacious for reducing TPs in women with FM. However, a need exists for additional well-designed and reported studies on this topic.

  4. A time domain inverse dynamic method for the end point tracking control of a flexible manipulator

    Science.gov (United States)

    Kwon, Dong-Soo; Book, Wayne J.

    1991-01-01

    The inverse dynamic equation of a flexible manipulator was solved in the time domain. By dividing the inverse system equation into the causal part and the anticausal part, we calculated the torque and the trajectories of all state variables for a given end point trajectory. The interpretation of this method in the frequency domain was explained in detail using the two-sided Laplace transform and the convolution integral. The open loop control of the inverse dynamic method shows an excellent result in simulation. For real applications, a practical control strategy is proposed by adding a feedback tracking control loop to the inverse dynamic feedforward control, and its good experimental performance is presented.

  5. Detecting Major Genetic Loci Controlling Phenotypic Variability in Experimental Crosses

    Science.gov (United States)

    Rönnegård, Lars; Valdar, William

    2011-01-01

    Traditional methods for detecting genes that affect complex diseases in humans or animal models, milk production in livestock, or other traits of interest, have asked whether variation in genotype produces a change in that trait’s average value. But focusing on differences in the mean ignores differences in variability about that mean. The robustness, or uniformity, of an individual’s character is not only of great practical importance in medical genetics and food production but is also of scientific and evolutionary interest (e.g., blood pressure in animal models of heart disease, litter size in pigs, flowering time in plants). We describe a method for detecting major genes controlling the phenotypic variance, referring to these as vQTL. Our method uses a double generalized linear model with linear predictors based on probabilities of line origin. We evaluate our method on simulated F2 and collaborative cross data, and on a real F2 intercross, demonstrating its accuracy and robustness to the presence of ordinary mean-controlling QTL. We also illustrate the connection between vQTL and QTL involved in epistasis, explaining how these concepts overlap. Our method can be applied to a wide range of commonly used experimental crosses and may be extended to genetic association more generally. PMID:21467569

  6. A Riccati Based Homogeneous and Self-Dual Interior-Point Method for Linear Economic Model Predictive Control

    DEFF Research Database (Denmark)

    Sokoler, Leo Emil; Frison, Gianluca; Edlund, Kristian

    2013-01-01

    In this paper, we develop an efficient interior-point method (IPM) for the linear programs arising in economic model predictive control of linear systems. The novelty of our algorithm is that it combines a homogeneous and self-dual model, and a specialized Riccati iteration procedure. We test...

  7. Distance majorization and its applications.

    Science.gov (United States)

    Chi, Eric C; Zhou, Hua; Lange, Kenneth

    2014-08-01

    The problem of minimizing a continuously differentiable convex function over an intersection of closed convex sets is ubiquitous in applied mathematics. It is particularly interesting when it is easy to project onto each separate set, but nontrivial to project onto their intersection. Algorithms based on Newton's method such as the interior point method are viable for small to medium-scale problems. However, modern applications in statistics, engineering, and machine learning are posing problems with potentially tens of thousands of parameters or more. We revisit this convex programming problem and propose an algorithm that scales well with dimensionality. Our proposal is an instance of a sequential unconstrained minimization technique and revolves around three ideas: the majorization-minimization principle, the classical penalty method for constrained optimization, and quasi-Newton acceleration of fixed-point algorithms. The performance of our distance majorization algorithms is illustrated in several applications.

  8. Intraflagellar transport particle size scales inversely with flagellar length: revisiting the balance-point length control model.

    Science.gov (United States)

    Engel, Benjamin D; Ludington, William B; Marshall, Wallace F

    2009-10-05

    The assembly and maintenance of eukaryotic flagella are regulated by intraflagellar transport (IFT), the bidirectional traffic of IFT particles (recently renamed IFT trains) within the flagellum. We previously proposed the balance-point length control model, which predicted that the frequency of train transport should decrease as a function of flagellar length, thus modulating the length-dependent flagellar assembly rate. However, this model was challenged by the differential interference contrast microscopy observation that IFT frequency is length independent. Using total internal reflection fluorescence microscopy to quantify protein traffic during the regeneration of Chlamydomonas reinhardtii flagella, we determined that anterograde IFT trains in short flagella are composed of more kinesin-associated protein and IFT27 proteins than trains in long flagella. This length-dependent remodeling of train size is consistent with the kinetics of flagellar regeneration and supports a revised balance-point model of flagellar length control in which the size of anterograde IFT trains tunes the rate of flagellar assembly.

  9. Automatic dew-point hygrometer making use of US -ray backscattering and controlled at the constant amount of dew

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Shigeaki; Kobayashi, Hisanobu

    1988-08-01

    A control system which consists of proportional and integral control to maintain the constant amount of dew was developed in this hygrometer. The dew points were measured within an accuracy of +-1 deg C in the ranging from -4 to 32 deg C. The response time for suddenly changing humidity was about 8 min.

  10. Magic Pointing for Eyewear Computers

    DEFF Research Database (Denmark)

    Jalaliniya, Shahram; Mardanbegi, Diako; Pederson, Thomas

    2015-01-01

    In this paper, we propose a combination of head and eye movements for touchlessly controlling the "mouse pointer" on eyewear devices, exploiting the speed of eye pointing and accuracy of head pointing. The method is a wearable computer-targeted variation of the original MAGIC pointing approach...... which combined gaze tracking with a classical mouse device. The result of our experiment shows that the combination of eye and head movements is faster than head pointing for far targets and more accurate than eye pointing....

  11. Alterations of serum macro-minerals and trace elements are associated with major depressive disorder: a case-control study.

    Science.gov (United States)

    Islam, Md Rabiul; Islam, Md Reazul; Shalahuddin Qusar, M M A; Islam, Mohammad Safiqul; Kabir, Md Humayun; Mustafizur Rahman, G K M; Islam, Md Saiful; Hasnat, Abul

    2018-04-10

    Major depressive disorder (MDD) is a mixed disorder with the highly irregular course, inconsistent response to treatment and has no well-known mechanism for the pathophysiology. Major causes of depression are genetic, neurobiological, and environmental. However, over the past few years, altered serum levels of macro-minerals (MM) and trace elements (TE) have been recognized as major causative factors to the pathogenesis of many mental disorders. The purpose of this study was to determine the serum levels of MM (calcium and magnesium) and TE (copper, iron, manganese, selenium, and zinc) in MDD patients and find out their associations with depression risk. This prospective case-control study recruited 247 patients and 248 healthy volunteers matched by age and sex. The serum levels of MM and TE were analyzed by atomic absorption spectroscopy (AAS). Statistical analysis was performed with independent sample t-tests and Pearson's correlation test. We found significantly decreased concentrations of calcium and magnesium, iron, manganese, selenium, and zinc in MDD patients compared with control subjects (p < 0.05). But the concentration of copper was significantly increased in the patients than control subjects (p < 0.05). Data obtained from different inter-element relations in MDD patients and control subjects strongly suggest that there is a disturbance in the element homeostasis. Our study suggests that altered serum concentrations of MM and TE are major contributing factors for the pathogenesis of MDD. Alterations of these elements in serum levels of MDD patients arise independently and they may provide a prognostic tool for the assessment of depression risk.

  12. Optimization Of Scan Range For 3d Point Localization In Statscan Digital Medical Radiology

    Directory of Open Access Journals (Sweden)

    Jacinta S. Kimuyu

    2015-08-01

    Full Text Available The emergence of computerized medical imaging in early 1970s which merged with digital technology in the 1980s was celebrated as a major breakthrough in three-dimensional 3D medicine. However a recent South African innovation the high speed scanning Lodox Statscan Critical Digital Radiology modality posed challenges in X-ray photogrammetry due to the systems intricate imaging geometry. The study explored the suitability of the Direct Linear Transformation as a method for the determination of 3D coordinates of targeted points from multiple images acquired with the Statscan X-ray system and optimization of the scan range. This investigation was carried out as a first step towards the development of a method to determine the accurate positions of points on or inside the human body. The major causes of errors in three-dimensional point localization using Statscan images were firstly the X-ray beam divergence and secondly the position of the point targets above the X-ray platform. The experiments carried out with two reference frames showed that point positions could be established with RMS values in the mm range in the middle axis of the X-ray patient platform. This range of acceptable mm accuracies extends about 15 to 20 cm sideways towards the edge of the X-ray table and to about 20 cm above the table surface. Beyond this range accuracy deteriorated significantly reaching RMS values of 30mm to 40 mm. The experiments further showed that the inclusion of control points close to the table edges and more than 20 cm above the table resulted in lower accuracies for the L - parameters of the DLT solution than those derived from points close to the center axis only. As the accuracy of the L - parameters propagates into accuracy of the final coordinates of newly determined points it is essential to restrict the space of the control points to the above described limits. If one adopts the usual approach of surrounding the object by known control points then

  13. Evolution of Motor Control: From Reflexes and Motor Programs to the Equilibrium-Point Hypothesis

    OpenAIRE

    Latash, Mark L.

    2008-01-01

    This brief review analyzes the evolution of motor control theories along two lines that emphasize active (motor programs) and reactive (reflexes) features of voluntary movements. It suggests that the only contemporary hypothesis that integrates both approaches in a fruitful way is the equilibrium-point hypothesis. Physical, physiological, and behavioral foundations of the EP-hypothesis are considered as well as relations between the EP-hypothesis and the recent developments of the notion of m...

  14. Stabilization at almost arbitrary points for chaotic systems

    International Nuclear Information System (INIS)

    Huang, C.-S.; Lian, K.-Y.; Su, C.-H.; Wu, J.-W.

    2008-01-01

    We consider how to design a feasible control input for chaotic systems via a suitable input channel to achieve the stabilization at arbitrary points. Regarding the nonlinear systems without naturally defined input vectors, we propose a local stabilization controller which works for almost arbitrary points. Subsequently, according to topologically transitive property for chaotic systems, the feedback control force is activated only when the trajectory passes through the neighboring region of the regulated point. Hence the global stabilization is achieved whereas the control effort of the hybrid controller is extremely low

  15. 40 CFR 63.1586 - What are the emission points and control requirements for a non-industrial POTW treatment plant?

    Science.gov (United States)

    2010-07-01

    ... control requirements for a non-industrial POTW treatment plant? 63.1586 Section 63.1586 Protection of... Pollutants: Publicly Owned Treatment Works Non-Industrial Potw Treatment Plant Requirements § 63.1586 What are the emission points and control requirements for a non-industrial POTW treatment plant? There are...

  16. Neural set point for the control of arterial pressure: role of the nucleus tractus solitarius

    Directory of Open Access Journals (Sweden)

    Valentinuzzi Max E

    2010-01-01

    Full Text Available Abstract Background Physiological experiments have shown that the mean arterial blood pressure (MAP can not be regulated after chemo and cardiopulmonary receptor denervation. Neuro-physiological information suggests that the nucleus tractus solitarius (NTS is the only structure that receives information from its rostral neural nuclei and from the cardiovascular receptors and projects to nuclei that regulate the circulatory variables. Methods From a control theory perspective, to answer if the cardiovascular regulation has a set point, we should find out whether in the cardiovascular control there is something equivalent to a comparator evaluating the error signal (between the rostral projections to the NTS and the feedback inputs. The NTS would function as a comparator if: a its lesion suppresses cardiovascular regulation; b the negative feedback loop still responds normally to perturbations (such as mechanical or electrical after cutting the rostral afferent fibers to the NTS; c perturbation of rostral neural structures (RNS to the NTS modifies the set point without changing the dynamics of the elicited response; and d cardiovascular responses to perturbations on neural structures within the negative feedback loop compensate for much faster than perturbations on the NTS rostral structures. Results From the control theory framework, experimental evidence found currently in the literature plus experimental results from our group was put together showing that the above-mentioned conditions (to show that the NTS functions as a comparator are satisfied. Conclusions Physiological experiments suggest that long-term blood pressure is regulated by the nervous system. The NTS functions as a comparator (evaluating the error signal between its RNS and the cardiovascular receptor afferents and projects to nuclei that regulate the circulatory variables. The mean arterial pressure (MAP is regulated by the feedback of chemo and cardiopulmonary receptors and

  17. The implementation of a Hazard Analysis and Critical Control Point management system in a peanut butter ice cream plant

    Directory of Open Access Journals (Sweden)

    Yu-Ting Hung

    2015-09-01

    Full Text Available To ensure the safety of the peanut butter ice cream manufacture, a Hazard Analysis and Critical Control Point (HACCP plan has been designed and applied to the production process. Potential biological, chemical, and physical hazards in each manufacturing procedure were identified. Critical control points for the peanut butter ice cream were then determined as the pasteurization and freezing process. The establishment of a monitoring system, corrective actions, verification procedures, and documentation and record keeping were followed to complete the HACCP program. The results of this study indicate that implementing the HACCP system in food industries can effectively enhance food safety and quality while improving the production management.

  18. Geometric Correction of PHI Hyperspectral Image without Ground Control Points

    International Nuclear Information System (INIS)

    Luan, Kuifeng; Tong, Xiaohua; Liu, Xiangfeng; Ma, Yanhua; Shu, Rong; Xu, Weiming

    2014-01-01

    Geometric correction without ground control points (GCPs) is a very important topic. Conventional airborne photogrammetry is difficult to implement in areas where the installation of GCPs is not available. The technical of integrated GPS/INS systems providing the positioning and attitude of airborne systems is a potential solution in such areas. This paper first states the principle of geometric correction based on a combination of GPS and INS then the error of the geometric correction of Pushbroom Hyperspectral Imager (PHI) without GCP was analysed, then a flight test was carried out in an area of Damxung, Tibet. The experiment result showed that the error at straight track was small, generally less than 1 pixel, while the maximum error at cross track direction, was close to 2 pixels. The results show that geometric correction of PHI without GCP enables a variety of mapping products to be generated from airborne navigation and imagery data

  19. Control electronic platform based on floating-point DSP and FPGA for a NPC multilevel back-to-back converter

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Francisco J.; Cobreces, Santiago; Bueno, Emilio J.; Hernandez, Alvaro; Mateos, Raul; Espinosa, Felipe [Department of Electronics, University of Alcala, Alcala de Henares, Madrid (Spain)

    2008-09-15

    Modern energy concepts as Distributed Power Generation are changing the appearance of electric distribution and transmission and challenging power electronics researchers, which try to develop new solutions of electronic controllers. The aim is to enable the implementation of new and more complex control algorithms to verify the last standards related to the grid energy quality for new power converters, and, also, for equipments which nowadays are operating. This paper presents the design, implementation and test of a novel real-time controller for a Neutral Point Clamped (NPC) (three-level) multilevel converter based on a floating-point Digital Signal Processor (DSP) and on a Field-Programmable Gate Array (FPGA), by operating in a cooperative way. Although the proposed system can be readily applied to any power electronic application, in this work, it is focused on the next system: a 150 kVA back-to-back three-level NPC Voltage Source Converter (VSC) for wind power applications. (author)

  20. A scanning point source for quality control of FOV uniformity in GC-PET imaging

    International Nuclear Information System (INIS)

    Bergmann, H.; Minear, G.; Dobrozemsky, G.; Nowotny, R.; Koenig, B.

    2002-01-01

    Aim: PET imaging with coincidence cameras (GC-PET) requires additional quality control procedures to check the function of coincidence circuitry and detector zoning. In particular, the uniformity response over the field of view needs special attention since it is known that coincidence counting mode may suffer from non-uniformity effects not present in single photon mode. Materials and methods: An inexpensive linear scanner with a stepper motor and a digital interface to a PC with software allowing versatile scanning modes was developed. The scanner is used with a source holder containing a Sodium-22 point source. While moving the source along the axis of rotation of the GC-PET system, a tomographic acquisition takes place. The scan covers the full axial field of view of the 2-D or 3-D scatter frame. Depending on the acquisition software, point source scanning takes place continuously while only one projection is acquired or is done in step-and-shoot mode with the number of positions equal to the number of gantry steps. Special software was developed to analyse the resulting list mode acquisition files and to produce an image of the recorded coincidence events of each head. Results: Uniformity images of coincidence events were obtained after further correction for systematic sensitivity variations caused by acquisition geometry. The resulting images are analysed visually and by calculating NEMA uniformity indices as for a planar flood field. The method has been applied successfully to two different brands of GC-PET capable gamma cameras. Conclusion: Uniformity of GC-PET can be tested quickly and accurately with a routine QC procedure, using a Sodium-22 scanning point source and an inexpensive mechanical scanning device. The method can be used for both 2-D and 3-D acquisition modes and fills an important gap in the quality control system for GC-PET

  1. Comprehensive Interpretation of a Three-Point Gauss Quadrature with Variable Sampling Points and Its Application to Integration for Discrete Data

    Directory of Open Access Journals (Sweden)

    Young-Doo Kwon

    2013-01-01

    Full Text Available This study examined the characteristics of a variable three-point Gauss quadrature using a variable set of weighting factors and corresponding optimal sampling points. The major findings were as follows. The one-point, two-point, and three-point Gauss quadratures that adopt the Legendre sampling points and the well-known Simpson’s 1/3 rule were found to be special cases of the variable three-point Gauss quadrature. In addition, the three-point Gauss quadrature may have out-of-domain sampling points beyond the domain end points. By applying the quadratically extrapolated integrals and nonlinearity index, the accuracy of the integration could be increased significantly for evenly acquired data, which is popular with modern sophisticated digital data acquisition systems, without using higher-order extrapolation polynomials.

  2. Can Ashi points stimulation have specific effects on shoulder pain? A systematic review of randomized controlled trials.

    Science.gov (United States)

    Wang, Kang-Feng; Zhang, Li-Juan; Lu, Feng; Lu, Yong-Hui; Yang, Chuan-Hua

    2016-06-01

    To provide an evidence-based overview regarding the efficacy of Ashi points stimulation for the treatment of shoulder pain. A comprehensive search [PubMed, Chinese Biomedical Literature Database, China National Knowledge Infrastructure (CNKI), Chongqing Weipu Database for Chinese Technical Periodicals (VIP) and Wanfang Database] was conducted to identify randomized or quasi-randomized controlled trials that evaluated the effectiveness of Ashi points stimulation for shoulder pain compared with conventional treatment. The methodological quality of the included studies was assessed using the Cochrane risk of bias tool. RevMan 5.0 was used for data synthesis. Nine trials were included. Seven studies assessed the effectiveness of Ashi points stimulation on response rate compared with conventional acupuncture. Their results suggested significant effect in favour of Ashi points stimulation [odds ratio (OR): 5.89, 95% confidence interval (CI): 2.97 to 11.67, Pfirm conclusion could not be reached until further studies of high quality are available.

  3. Plant litter dynamics in the forest-stream interface: precipitation is a major control across tropical biomes.

    Science.gov (United States)

    Tonin, Alan M; Gonçalves, José F; Bambi, Paulino; Couceiro, Sheyla R M; Feitoza, Lorrane A M; Fontana, Lucas E; Hamada, Neusa; Hepp, Luiz U; Lezan-Kowalczuk, Vânia G; Leite, Gustavo F M; Lemes-Silva, Aurea L; Lisboa, Leonardo K; Loureiro, Rafael C; Martins, Renato T; Medeiros, Adriana O; Morais, Paula B; Moretto, Yara; Oliveria, Patrícia C A; Pereira, Evelyn B; Ferreira, Lidiane P; Pérez, Javier; Petrucio, Mauricio M; Reis, Deusiano F; S Rezende, Renan; Roque, Nadia; Santos, Luiz E P; Siegloch, Ana E; Tonello, Gabriela; Boyero, Luz

    2017-09-07

    Riparian plant litter is a major energy source for forested streams across the world and its decomposition has repercussions on nutrient cycling, food webs and ecosystem functioning. However, we know little about plant litter dynamics in tropical streams, even though the tropics occupy 40% of the Earth's land surface. Here we investigated spatial and temporal (along a year cycle) patterns of litter inputs and storage in multiple streams of three tropical biomes in Brazil (Atlantic forest, Amazon forest and Cerrado savanna), predicting major differences among biomes in relation to temperature and precipitation regimes. Precipitation explained most of litter inputs and storage, which were generally higher in more humid biomes (litterfall: 384, 422 and 308 g m -2 y -1 , storage: 55, 113 and 38 g m -2 , on average in Atlantic forest, Amazon and Cerrado, respectively). Temporal dynamics varied across biomes in relation to precipitation and temperature, with uniform litter inputs but seasonal storage in Atlantic forest streams, seasonal inputs in Amazon and Cerrado streams, and aseasonal storage in Amazon streams. Our findings suggest that litter dynamics vary greatly within the tropics, but point to the major role of precipitation, which contrasts with the main influence of temperature in temperate areas.

  4. Simulation model of ANN based maximum power point tracking controller for solar PV system

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Anil K.; Singh, Bhupal [Department of Electrical and Electronics Engineering, Ajay Kumar Garg Engineering College, Ghaziabad 201009 (India); Kaushika, N.D.; Agarwal, Niti [School of Research and Development, Bharati Vidyapeeth College of Engineering, A-4 Paschim Vihar, New Delhi 110063 (India)

    2011-02-15

    In this paper the simulation model of an artificial neural network (ANN) based maximum power point tracking controller has been developed. The controller consists of an ANN tracker and the optimal control unit. The ANN tracker estimates the voltages and currents corresponding to a maximum power delivered by solar PV (photovoltaic) array for variable cell temperature and solar radiation. The cell temperature is considered as a function of ambient air temperature, wind speed and solar radiation. The tracker is trained employing a set of 124 patterns using the back propagation algorithm. The mean square error of tracker output and target values is set to be of the order of 10{sup -5} and the successful convergent of learning process takes 1281 epochs. The accuracy of the ANN tracker has been validated by employing different test data sets. The control unit uses the estimates of the ANN tracker to adjust the duty cycle of the chopper to optimum value needed for maximum power transfer to the specified load. (author)

  5. Synthetic organic agrochemicals in the lower Mississippi River and its major tributaries: Distribution, transport and fate

    Science.gov (United States)

    Pereira, W.E.; Rostad, C.E.; Leiker, T.J.; ,

    1992-01-01

    The Mississippi River and its major tributaries transport herbicides and their degradation products from agricultural areas in the mid-western U.S.A. These compounds include atrazine and its degradation products (desethyl- and desisopropylatrazine), simazine, cyanazine, metolachlor, and alachlor and its degradation products (2-chloro-2',6'-diethylacetanilide, 2-hydroxy-2',6'-diethylacetanilide and 2,6-diethylaniline). These compounds were identified and confirmed by gas chromatography-ion trap mass spectrometry. Loads of these compounds were determined during five sampling trips in 1987-1989. Stream loads of these compounds indicated that atrazine and metolachlor were relatively conservative in downstream transport. Alachlor and its degradation products were generated from point and non-point sources. Seasonal variations and hydrologic conditions controlled the loads of these compounds in the Mississippi River. Cross-channel mixing was slow downstream from major river confluences, possibly requiring several hundred kilometers of downriver transit for completion. The annual transport of these compounds into the Gulf of Mexico was estimated to be < 2% of the annual application of each herbicide in the Midwest.The Mississippi River and its major tributaries transport herbicides and their degradation products from agricultural areas in the mid-western U.S.A. These compounds include atrazine and its degradation products (desethyl- and desisopropylatrazine), simazine, cyanazine, metolachlor, and alachlor and its degradation products (2-chloro-2???,6???-diethylacetanilide, 2-hydroxy-2???,6???-diethylacetanilide and 2,6-diethylaniline). These compounds were identified and confirmed by gas chromatography-ion trap mass spectrometry. Loads of these compounds were determined during five sampling trips in 1987-1989. Stream loads of these compounds indicated that atrazine and metolachlor were relatively conservative in downstream transport. Alachlor and its degradation products

  6. Examining Person--Environment Fit and Academic Major Satisfaction

    Science.gov (United States)

    Milsom, Amy; Coughlin, Julie

    2017-01-01

    Decisions regarding college majors have the potential to affect a person's overall academic performance and long-term career success. With Holland's (1997) trait-and-factor theory serving as a foundation, the authors examined relationships between person-environment fit, college major satisfaction, and grade point average of undergraduate students…

  7. HACCP (Hazard Analysis Critical Control Points): is it coming to the dairy?

    Science.gov (United States)

    Cullor, J S

    1997-12-01

    The risks and consequences of foodborne and waterborne pathogens are coming to the forefront of public health concerns, and strong pressure is being applied on agriculture for immediate implementation of on-farm controls. The FDA is considering HACCP (Hazard Analysis Critical Control Points) as the new foundation for revision of the US Food Safety Assurance Program because HACCP is considered to be a science-based, systematic approach to the prevention of food safety problems. In addition, the implementation of HACCP principles permits more government oversight through requirements for standard operating procedures and additional systems for keeping records, places primary responsibility for ensuring food safety on the food manufacturer or distributor, and may assist US food companies in competing more effectively in the world market. With the HACCP-based program in place, a government investigator should be able to determine and evaluate both current and past conditions that are critical to ensuring the safety of the food produced by the facility. When this policy is brought to the production unit, the impact for producers and veterinarians will be substantial.

  8. The implementation of a Hazard Analysis and Critical Control Point management system in a peanut butter ice cream plant.

    Science.gov (United States)

    Hung, Yu-Ting; Liu, Chi-Te; Peng, I-Chen; Hsu, Chin; Yu, Roch-Chui; Cheng, Kuan-Chen

    2015-09-01

    To ensure the safety of the peanut butter ice cream manufacture, a Hazard Analysis and Critical Control Point (HACCP) plan has been designed and applied to the production process. Potential biological, chemical, and physical hazards in each manufacturing procedure were identified. Critical control points for the peanut butter ice cream were then determined as the pasteurization and freezing process. The establishment of a monitoring system, corrective actions, verification procedures, and documentation and record keeping were followed to complete the HACCP program. The results of this study indicate that implementing the HACCP system in food industries can effectively enhance food safety and quality while improving the production management. Copyright © 2015. Published by Elsevier B.V.

  9. 75 FR 8239 - School Food Safety Program Based on Hazard Analysis and Critical Control Point Principles (HACCP...

    Science.gov (United States)

    2010-02-24

    ... (HACCP); Approval of Information Collection Request AGENCY: Food and Nutrition Service, USDA. ACTION... Safety Program Based on Hazard Analysis and Critical Control Point Principles (HACCP) was published on... must be based on the (HACCP) system established by the Secretary of Agriculture. The food safety...

  10. Laser Dew-Point Hygrometer

    Science.gov (United States)

    Matsumoto, Shigeaki; Toyooka, Satoru

    1995-01-01

    A rough-surface-type automatic dew-point hygrometer was developed using a laser diode and an optical fiber cable. A gold plate with 0.8 µ m average surface roughness was used as a surface for deposition of dew to facilitate dew deposition and prevent supersaturation of water vapor at the dew point. It was shown experimentally that the quantity of dew deposited can be controlled to be constant at any predetermined level, and is independent of the dew point to be measured. The dew points were measured in the range from -15° C to 54° C in which the temperature ranged from 0° C to 60° C. The measurement error of the dew point was ±0.5° C which was equal to below ±2% in relative humidity in the above dew-point range.

  11. The Major Genetic Determinants of HIV-1 Control Affect HLA Class I Peptide Presentation

    OpenAIRE

    Pereyra, Florencia; Jia, Xiaoming; McLaren, Paul J.; Telenti, Amalio; de Bakker, Paul I.W.; Walker, Bruce D.; Jia, Xiaoming; McLaren, Paul J.; Ripke, Stephan; Brumme, Chanson J.; Pulit, Sara L.; Telenti, Amalio; Carrington, Mary; Kadie, Carl M.; Carlson, Jonathan M.

    2010-01-01

    Infectious and inflammatory diseases have repeatedly shown strong genetic associations within the major histocompatibility complex (MHC); however, the basis for these associations remains elusive. To define host genetic effects on the outcome of a chronic viral infection, we performed genome-wide association analysis in a multiethnic cohort of HIV-1 controllers and progressors, and we analyzed the effects of individual amino acids within the classical human leukocyte antigen (HLA) proteins. W...

  12. Investigating Prospective Teachers' Perceived Problem-Solving Abilities in Relation to Gender, Major, Place Lived, and Locus of Control

    Science.gov (United States)

    Çakir, Mustafa

    2017-01-01

    The purpose of this study is to investigate prospective teachers' perceived personal problem-solving competencies in relation to gender, major, place lived, and internal-external locus of control. The Personal Problem-Solving Inventory and Rotter's Internal-External Locus of Control Scale were used to collect data from freshman teacher candidates…

  13. [Preliminary studies on critical control point of traceability system in wolfberry].

    Science.gov (United States)

    Liu, Sai; Xu, Chang-Qing; Li, Jian-Ling; Lin, Chen; Xu, Rong; Qiao, Hai-Li; Guo, Kun; Chen, Jun

    2016-07-01

    As a traditional Chinese medicine, wolfberry (Lycium barbarum) has a long cultivation history and a good industrial development foundation. With the development of wolfberry production, the expansion of cultivation area and the increased attention of governments and consumers on food safety, the quality and safety requirement of wolfberry is higher demanded. The quality tracing and traceability system of production entire processes is the important technology tools to protect the wolfberry safety, and to maintain sustained and healthy development of the wolfberry industry. Thus, this article analyzed the wolfberry quality management from the actual situation, the safety hazard sources were discussed according to the HACCP (hazard analysis and critical control point) and GAP (good agricultural practice for Chinese crude drugs), and to provide a reference for the traceability system of wolfberry. Copyright© by the Chinese Pharmaceutical Association.

  14. Variable Parameter Nonlinear Control for Maximum Power Point Tracking Considering Mitigation of Drive-train Load

    Institute of Scientific and Technical Information of China (English)

    Zaiyu; Chen; Minghui; Yin; Lianjun; Zhou; Yaping; Xia; Jiankun; Liu; Yun; Zou

    2017-01-01

    Since mechanical loads exert a significant influence on the life span of wind turbines, the reduction of transient load on drive-train shaft has received more attention when implementing a maximum power point tracking(MPPT) controller.Moreover, a trade-off between the efficiency of wind energy extraction and the load level of drive-train shaft becomes a key issue. However, for the existing control strategies based on nonlinear model of wind turbines, the MPPT efficiencies are improved at the cost of the intensive fluctuation of generator torque and significant increase of transient load on drive train shaft. Hence, in this paper, a nonlinear controller with variable parameter is proposed for improving MPPT efficiency and mitigating transient load on drive-train simultaneously. Then,simulations on FAST(Fatigue, Aerodynamics, Structures, and Turbulence) code and experiments on the wind turbine simulator(WTS) based test bench are presented to verify the efficiency improvement of the proposed control strategy with less cost of drive-train load.

  15. Variable Parameter Nonlinear Control for Maximum Power Point Tracking Considering Mitigation of Drive-train Load

    Institute of Scientific and Technical Information of China (English)

    Zaiyu Chen; Minghui Yin; Lianjun Zhou; Yaping Xia; Jiankun Liu; Yun Zou

    2017-01-01

    Since mechanical loads exert a significant influence on the life span of wind turbines,the reduction of transient load on drive-train shaft has received more attention when implementing a maximum power point tracking (MPPT) controller.Moreover,a trade-off between the efficiency of wind energy extraction and the load level of drive-train shaft becomes a key issue.However,for the existing control strategies based on nonlinear model of wind turbines,the MPPT efficiencies are improved at the cost of the intensive fluctuation of generator torque and significant increase of transient load on drive train shaft.Hence,in this paper,a nonlinear controller with variable parameter is proposed for improving MPPT efficiency and mitigating transient load on drive-train simultaneously.Then,simulations on FAST (Fatigue,Aerodynamics,Structures,and Turbulence) code and experiments on the wind turbine simulator (WTS) based test bench are presented to verify the efficiency improvement of the proposed control strategy with less cost of drive-train load.

  16. Prevention and Control of Agricultural Non-Point Source Pollutions in UK and Suggestions to China

    OpenAIRE

    Liu, Kun; Ren, Tianzhi; Wu, Wenliang; Meng, Fanquiao; Bellarby, Jessica; Smith, Laurence

    2016-01-01

    Currently, the world is facing challenges of maintaining food production growth while improving agricultural ecological environmental quality. The prevention and control of agricultural non-point source pollution, a key component of these challenges, is a systematic program which integrates many factors such as technology and its extension, relevant regulation and policies. In the project of UK-China Sustainable Agriculture Innovation Network, we undertook a comprehensive analysis of the prev...

  17. Part I: Hazard, sensorial and economic implications of applying the hazard analysis and critical control points to irradiated ready-to-eat meals

    International Nuclear Information System (INIS)

    Haruvy, Y.F.

    2009-01-01

    The classical methodology of hazard analysis and critical control points focuses on hazards and related implications. A new methodology is suggested here, one that attempts at a systematic simultaneous assessment of safety hazards, sensorial failures and economic risks, and the critical control points necessary for their early detection and/or prevention of their potential outcomes. The new methodology also attempts to combine the three parameters to form a qualitative prioritization of the numerous control points and to screen those that can be cost effective for implementation. This is demonstrated in this paper for a complex product, i.e. radiation sterilized ready-to-eat meals. Hence, a fourth parameter specific to this product - the radiation specific pitfall - is also assessed. The advantages and drawbacks of the combined assessment methodology are described and their overall possible impact is discussed. Finally, the suggested combined assessment and control system for ensuring the safety and quality of food can provide a more structured and critical approach to control identified hazards, compared with that achievable by traditional inspection and quality control procedures. It has the potential to identify areas of concern where failure has not yet been experienced, making it particularly useful for new operations and products thereafter. (author)

  18. Personality, academic majors and performance

    DEFF Research Database (Denmark)

    Vedel, Anna; Thomsen, Dorthe Kirkegaard; Larsen, Lars

    2015-01-01

    Personality–performance research typically uses samples of psychology students without questioning their representativeness. The present article reports two studies challenging this practice. Study 1: group differences in the Big Five personality traits were explored between students (N = 1067......) in different academic majors (medicine, psychology, law, economics, political science, science, and arts/humanities), who were tested immediately after university enrolment. Study 2: six and a half years later the students’ academic records were obtained, and predictive validity of the Big Five personality...... traits and their subordinate facets was examined in the various academic majors in relation to Grade Point Average (GPA). Significant group differences in all Big Five personality traits were found between students in different academic majors. Also, variability in predictive validity of the Big Five...

  19. Hazard analysis and critical control point to irradiated food in Brazil

    International Nuclear Information System (INIS)

    Boaratti, Maria de Fatima Guerra

    2004-01-01

    Food borne diseases, in particular gastro-intestinal infections, represent a very large group of pathologies with a strong negative impact on the health of the population because of their widespread nature. Little consideration is given to such conditions due to the fact that their symptoms are often moderate and self-limiting. This has led to a general underestimation of their importance, and consequently to incorrect practices during the preparation and preservation of food, resulting in the frequent occurrence of outbreaks involving groups of varying numbers of consumers. Despite substantial efforts in the avoidance of contamination, an upward trend in the number of outbreaks of food borne illnesses caused by non-spore forming pathogenic bacteria are reported in many countries. Good hygienic practices can reduce the level of contamination but the most important pathogens cannot presently be eliminated from most farms, nor is it possible to eliminate them by primary processing, particularly from those foods which are sold raw. Several decontamination methods exist but the most versatile treatment among them is the ionizing radiation procedure. HACCP (Hazard Analysis and Critical Control Point) is a management system in which food safety is addressed through the analysis and control of biological, chemical, and physical hazards from raw material production, procurement and handling, to manufacturing, distribution and consumption of the finished product. For successful implementation of a HACCP plan, management must be strongly committed to the HACCP concept. A firm commitment to HACCP by top management provides company employees with a sense of the importance of producing safe food. At the same time, it has to be always emphasized that, like other intervention strategies, irradiation must be applied as part of a total sanitation program. The benefits of irradiation should never be considered as an excuse for poor quality or for poor handling and storage conditions

  20. The Point Lepreau Desktop Simulator

    International Nuclear Information System (INIS)

    MacLean, M.; Hogg, J.; Newman, H.

    1997-01-01

    The Point Lepreau Desktop Simulator runs plant process modeling software on a 266 MHz single CPU DEC Alpha computer. This same Alpha also runs the plant control computer software on an SSCI 125 emulator. An adjacent Pentium PC runs the simulator's Instructor Facility software, and communicates with the Alpha through an Ethernet. The Point Lepreau Desktop simulator is constructed to be as similar as possible to the Point Lepreau full scope training simulator. This minimizes total maintenance costs and enhances the benefits of the desktop simulator. Both simulators have the same modeling running on a single CPU in the same schedule of calculations. Both simulators have the same Instructor Facility capable of developing and executing the same lesson plans, doing the same monitoring and control of simulations, inserting all the same malfunctions, performing all the same overrides, capable of making and restoring all the same storepoints. Both simulators run the same plant control computer software - the same assembly language control programs as the power plant uses for reactor control, heat transport control, annunciation, etc. This is a higher degree of similarity between a desktop simulator and a full scope training simulator than previously reported for a computer controlled nuclear plant. The large quantity of control room hardware missing from the desktop simulator is replaced by software. The Instructor Facility panel override software of the training simulator provides the means by which devices (switches, controllers, windows, etc.) on the control room panels can be controlled and monitored in the desktop simulator. The CRT of the Alpha provides a mouse operated DCC keyboard mimic for controlling the plant control computer emulation. Two emulated RAMTEK display channels appear as windows for monitoring anything of interest on plant DCC displays, including one channel for annunciation. (author)

  1. Incorporation of Complex Hydrological and Socio-economic Factors for Non-point Source Pollution Control: A Case Study at the Yincungang Canal, the Lake Tai Basin of China

    Science.gov (United States)

    Yang, X.; Luo, X.; Zheng, Z.

    2012-04-01

    It is increasingly realized that non-point pollution sources contribute significantly to water environment deterioration in China. Compared to developed countries, non-point source pollution in China has the unique characteristics of strong intensity and composition complexity due to its special socioeconomic conditions. First, more than 50% of its 1.3 billion people are rural. Sewage from the majority of the rural households is discharged either without or only with minimal treatment. The large amount of erratic rural sewage discharge is a significant source of water pollution. Second, China is plagued with serious agricultural pollution due to widespread improper application of fertilizers and pesticides. Finally, there lack sufficient disposal and recycling of rural wastes such as livestock manure and crop straws. Pollutant loads from various sources have far exceeded environmental assimilation capacity in many parts of China. The Lake Tai basin is one typical example. Lake Tai is the third largest freshwater lake in China. The basin is located in the highly developed and densely populated Yangtze River Delta. While accounting for 0.4% of its land area and 2.9% of its population, the Lake Tai basin generates more than 14% of China's Gross Domestic Production (GDP), and the basin's GDP per capita is 3.5 times as much as the state average. Lake Tai is vital to the basin's socio-economic development, providing multiple services including water supply for municipal, industrial, and agricultural needs, navigation, flood control, fishery, and tourism. Unfortunately, accompanied with the fast economic development is serious water environment deterioration in the Lake Tai basin. The lake is becoming increasingly eutrophied and has frequently suffered from cyanobacterial blooms in recent decades. Chinese government has made tremendous investment in order to mitigate water pollution conditions in the basin. Nevertheless, the trend of deteriorating water quality has yet to

  2. Neuromodulation of Attentional Control in Major Depression: A Pilot DeepTMS Study

    Directory of Open Access Journals (Sweden)

    Jodie Naim-Feil

    2016-01-01

    Full Text Available While Major Depressive Disorder (MDD is primarily characterized by mood disturbances, impaired attentional control is increasingly identified as a critical feature of depression. Deep transcranial magnetic stimulation (deepTMS, a noninvasive neuromodulatory technique, can modulate neural activity and induce neuroplasticity changes in brain regions recruited by attentional processes. This study examined whether acute and long-term high-frequency repetitive deepTMS to the dorsolateral prefrontal cortex (DLPFC can attenuate attentional deficits associated with MDD. Twenty-one MDD patients and 26 matched control subjects (CS were administered the Beck Depression Inventory and the Sustained Attention to Response Task (SART at baseline. MDD patients were readministered the SART and depressive assessments following a single session (n=21 and after 4 weeks (n=13 of high-frequency (20 Hz repetitive deepTMS applied to the DLPFC. To control for the practice effect, CS (n=26 were readministered the SART a further two times. The MDD group exhibited deficits in sustained attention and cognitive inhibition. Both acute and long-term high-frequency repetitive frontal deepTMS ameliorated sustained attention deficits in the MDD group. Improvement after acute deepTMS was related to attentional recovery after long-term deepTMS. Longer-term improvement in sustained attention was not related to antidepressant effects of deepTMS treatment.

  3. Neuromodulation of Attentional Control in Major Depression: A Pilot DeepTMS Study.

    Science.gov (United States)

    Naim-Feil, Jodie; Bradshaw, John L; Sheppard, Dianne M; Rosenberg, Oded; Levkovitz, Yechiel; Dannon, Pinhas; Fitzgerald, Paul B; Isserles, Moshe; Zangen, Abraham

    2016-01-01

    While Major Depressive Disorder (MDD) is primarily characterized by mood disturbances, impaired attentional control is increasingly identified as a critical feature of depression. Deep transcranial magnetic stimulation (deepTMS), a noninvasive neuromodulatory technique, can modulate neural activity and induce neuroplasticity changes in brain regions recruited by attentional processes. This study examined whether acute and long-term high-frequency repetitive deepTMS to the dorsolateral prefrontal cortex (DLPFC) can attenuate attentional deficits associated with MDD. Twenty-one MDD patients and 26 matched control subjects (CS) were administered the Beck Depression Inventory and the Sustained Attention to Response Task (SART) at baseline. MDD patients were readministered the SART and depressive assessments following a single session (n = 21) and after 4 weeks (n = 13) of high-frequency (20 Hz) repetitive deepTMS applied to the DLPFC. To control for the practice effect, CS (n = 26) were readministered the SART a further two times. The MDD group exhibited deficits in sustained attention and cognitive inhibition. Both acute and long-term high-frequency repetitive frontal deepTMS ameliorated sustained attention deficits in the MDD group. Improvement after acute deepTMS was related to attentional recovery after long-term deepTMS. Longer-term improvement in sustained attention was not related to antidepressant effects of deepTMS treatment.

  4. The research of the coupled orbital-attitude controlled motion of celestial body in the neighborhood of the collinear libration point L1

    Science.gov (United States)

    Shmyrov, A.; Shmyrov, V.; Shymanchuk, D.

    2017-10-01

    This article considers the motion of a celestial body within the restricted three-body problem of the Sun-Earth system. The equations of controlled coupled attitude-orbit motion in the neighborhood of collinear libration point L1 are investigated. The translational orbital motion of a celestial body is described using Hill's equations of circular restricted three-body problem of the Sun-Earth system. Rotational orbital motion is described using Euler's dynamic equations and quaternion kinematic equation. We investigate the problem of stability of celestial body rotational orbital motion in relative equilibrium positions and stabilization of celestial body rotational orbital motion with proposed control laws in the neighborhood of collinear libration point L1. To study stabilization problem, Lyapunov function is constructed in the form of the sum of the kinetic energy and special "kinematic function" of the Rodriguez-Hamiltonian parameters. Numerical modeling of the controlled rotational motion of a celestial body at libration point L1 is carried out. The numerical characteristics of the control parameters and rotational motion are given.

  5. Active control on high-order coherence and statistic characterization on random phase fluctuation of two classical point sources.

    Science.gov (United States)

    Hong, Peilong; Li, Liming; Liu, Jianji; Zhang, Guoquan

    2016-03-29

    Young's double-slit or two-beam interference is of fundamental importance to understand various interference effects, in which the stationary phase difference between two beams plays the key role in the first-order coherence. Different from the case of first-order coherence, in the high-order optical coherence the statistic behavior of the optical phase will play the key role. In this article, by employing a fundamental interfering configuration with two classical point sources, we showed that the high- order optical coherence between two classical point sources can be actively designed by controlling the statistic behavior of the relative phase difference between two point sources. Synchronous position Nth-order subwavelength interference with an effective wavelength of λ/M was demonstrated, in which λ is the wavelength of point sources and M is an integer not larger than N. Interestingly, we found that the synchronous position Nth-order interference fringe fingerprints the statistic trace of random phase fluctuation of two classical point sources, therefore, it provides an effective way to characterize the statistic properties of phase fluctuation for incoherent light sources.

  6. Analysing and controlling the tax evasion dynamics via majority-vote model

    Energy Technology Data Exchange (ETDEWEB)

    Lima, F W S, E-mail: fwslima@gmail.co, E-mail: wel@ufpi.edu.b [Departamento de Fisica, Universidade Federal do PiauI, 64049-550, Teresina - PI (Brazil)

    2010-09-01

    Within the context of agent-based Monte-Carlo simulations, we study the well-known majority-vote model (MVM) with noise applied to tax evasion on simple square lattices, Voronoi-Delaunay random lattices, Barabasi-Albert networks, and Erdoes-Renyi random graphs. In the order to analyse and to control the fluctuations for tax evasion in the economics model proposed by Zaklan, MVM is applied in the neighborhood of the noise critical q{sub c} to evolve the Zaklan model. The Zaklan model had been studied recently using the equilibrium Ising model. Here we show that the Zaklan model is robust because this can be studied using equilibrium dynamics of Ising model also through the nonequilibrium MVM and on various topologies cited above giving the same behavior regardless of dynamic or topology used here.

  7. Analysing and controlling the tax evasion dynamics via majority-vote model

    International Nuclear Information System (INIS)

    Lima, F W S

    2010-01-01

    Within the context of agent-based Monte-Carlo simulations, we study the well-known majority-vote model (MVM) with noise applied to tax evasion on simple square lattices, Voronoi-Delaunay random lattices, Barabasi-Albert networks, and Erdoes-Renyi random graphs. In the order to analyse and to control the fluctuations for tax evasion in the economics model proposed by Zaklan, MVM is applied in the neighborhood of the noise critical q c to evolve the Zaklan model. The Zaklan model had been studied recently using the equilibrium Ising model. Here we show that the Zaklan model is robust because this can be studied using equilibrium dynamics of Ising model also through the nonequilibrium MVM and on various topologies cited above giving the same behavior regardless of dynamic or topology used here.

  8. Investigating Clinically and Scientifically Useful Cut Points on the Compulsive Sexual Behavior Inventory.

    Science.gov (United States)

    Miner, Michael H; Raymond, Nancy; Coleman, Eli; Swinburne Romine, Rebecca

    2017-05-01

    One of the major obstacles to conducting epidemiologic research and determining the incidence and prevalence of compulsive sexual behavior (CSB) has been the lack of relevant empirically derived cut points on the various instruments that have been used to measure the concept. To further develop the Compulsive Sexual Behavior Inventory (CSBI) through exploring predictive validity and developing an empirically determined and clinically useful cut point for defining CSB. A sample of 242 men who have sex with men was recruited from various sites in a moderate-size Midwestern city. Participants were assigned to a CSB group or a control group using an interview for the diagnosis that was patterned after the Structured Clinical Interview for the Diagnostic and Statistical Manual for Mental Disorders, Fourth Edition. The 22-item CSBI was administered as part of a larger battery of self-report inventories. Receiver operating characteristic analyses were used to compute area-under-the-curve measurements to ascertain the predictive validity of the total scale, the control subscale, and the violence subscale. Cut points were determined through consensus of experts balancing sensitivity and specificity as determined by receiver operating characteristic curves. Analyses indicated that the 22-item CSBI was a good predictor of group membership, as was the 13-item control subscale. The violence subscale added little to the predictive accuracy of the instrument; thus, it likely measures something other than CSB. Two relevant cut points were found, one that minimized false negatives and another, more conservative cut point that minimized false positives. The CSBI as currently configured measures two different constructions and only the control subscale is helpful in diagnosing CSB. Therefore, we decided to eliminate the violence subscale and move forward with a 13-item scale that we have named the CSBI-13. Two cut points were developed from this revised scale, one that is useful as a

  9. Turning points in the history of mathematics

    CERN Document Server

    Grant, Hardy

    2015-01-01

    This book explores some of the major turning points in the history of mathematics, ranging from ancient Greece to the present, demonstrating the drama that has often been a part of its evolution. Studying these breakthroughs, transitions, and revolutions, their stumbling-blocks and their triumphs, can help illuminate the importance of the history of mathematics for its teaching, learning, and appreciation. Some of the turning points considered are the rise of the axiomatic method (most famously in Euclid), and the subsequent major changes in it (for example, by David Hilbert); the “wedding,” via analytic geometry, of algebra and geometry; the “taming” of the infinitely small and the infinitely large; the passages from algebra to algebras, from geometry to geometries, and from arithmetic to arithmetics; and the revolutions in the late nineteenth and early twentieth centuries that resulted from Georg Cantor’s creation of transfinite set theory. The origin of each turning point is discussed, along with...

  10. An automatic dew-point hygrometer making use of β-ray backscattering and controlled at the constant amount of dew

    International Nuclear Information System (INIS)

    Matsumoto, Shigeaki; Kobayashi, Hisanobu

    1988-01-01

    A control system which consists of proportional and integral control to maintain the constant amount of dew was developed in this hygrometer. The dew points were measured within an accuracy of ±1 deg C in the ranging from -4 to 32 deg C. The response time for suddenly changing humidity was about 8 min. (author)

  11. Maximum power point tracking-based control algorithm for PMSG wind generation system without mechanical sensors

    International Nuclear Information System (INIS)

    Hong, Chih-Ming; Chen, Chiung-Hsing; Tu, Chia-Sheng

    2013-01-01

    Highlights: ► This paper presents MPPT based control for optimal wind energy capture using RBFN. ► MPSO is adopted to adjust the learning rates to improve the learning capability. ► This technique can maintain the system stability and reach the desired performance. ► The EMF in the rotating reference frame is utilized in order to estimate speed. - Abstract: This paper presents maximum-power-point-tracking (MPPT) based control algorithms for optimal wind energy capture using radial basis function network (RBFN) and a proposed torque observer MPPT algorithm. The design of a high-performance on-line training RBFN using back-propagation learning algorithm with modified particle swarm optimization (MPSO) regulating controller for the sensorless control of a permanent magnet synchronous generator (PMSG). The MPSO is adopted in this study to adapt the learning rates in the back-propagation process of the RBFN to improve the learning capability. The PMSG is controlled by the loss-minimization control with MPPT below the base speed, which corresponds to low and high wind speed, and the maximum energy can be captured from the wind. Then the observed disturbance torque is feed-forward to increase the robustness of the PMSG system

  12. When should we recommend use of dual time-point and delayed time-point imaging techniques in FDG PET?

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Gang [Philadelphia VA Medical Center, Department of Radiology, Philadelphia, PA (United States); Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Torigian, Drew A.; Alavi, Abass [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Zhuang, Hongming [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2013-05-15

    FDG PET and PET/CT are now widely used in oncological imaging for tumor characterization, staging, restaging, and response evaluation. However, numerous benign etiologies may cause increased FDG uptake indistinguishable from that of malignancy. Multiple studies have shown that dual time-point imaging (DTPI) of FDG PET may be helpful in differentiating malignancy from benign processes. However, exceptions exist, and some studies have demonstrated significant overlap of FDG uptake patterns between benign and malignant lesions on delayed time-point images. In this review, we summarize our experience and opinions on the value of DTPI and delayed time-point imaging in oncology, with a review of the relevant literature. We believe that the major value of DTPI and delayed time-point imaging is the increased sensitivity due to continued clearance of background activity and continued FDG accumulation in malignant lesions, if the same diagnostic criteria (as in the initial standard single time-point imaging) are used. The specificity of DTPI and delayed time-point imaging depends on multiple factors, including the prevalence of malignancies, the patient population, and the cut-off values (either SUV or retention index) used to define a malignancy. Thus, DTPI and delayed time-point imaging would be more useful if performed for evaluation of lesions in regions with significant background activity clearance over time (such as the liver, the spleen, the mediastinum), and if used in the evaluation of the extent of tumor involvement rather than in the characterization of the nature of any specific lesion. Acute infectious and non-infectious inflammatory lesions remain as the major culprit for diminished diagnostic performance of these approaches (especially in tuberculosis-endemic regions). Tumor heterogeneity may also contribute to inconsistent performance of DTPI. The authors believe that selective use of DTPI and delayed time-point imaging will improve diagnostic accuracy and

  13. Tobacco point of sale advertising increases positive brand user imagery.

    Science.gov (United States)

    Donovan, R J; Jancey, J; Jones, S

    2002-09-01

    To determine the potential impact of point of sale advertising on adolescents so as to inform changes to the Tobacco Control Act. Participants were randomly assigned to one of two conditions. In the control condition, students were exposed to a photograph of a packet of cigarettes; in the intervention condition, students were exposed to an ad for cigarettes, typical of point of sale advertising posters. All students then rated the brand user on a set of 12 bipolar adjectives. Two brands were used in the study: Benson & Hedges, and Marlboro. One hundred year (grade) 6 and 7 students (age range 10-12 years), from four Western Australian metropolitan primary schools, participated in the study. In a majority of the brand user descriptions, the cigarette advertisements increased brand user imagery in a positive way, especially for Benson & Hedges. For example, participants viewing the Benson & Hedges advertisement, as distinct from those viewing the Benson & Hedges pack only, were more likely to describe the Benson & Hedges user as relaxed, interesting, cool, rich, adventurous, and classy. Relative to the Marlboro pack only, the Marlboro ad increased positive perceptions of the Marlboro user on adventurous, interesting, and relaxed. The results presented here support restrictions being placed on advertising at point of sale, since such ads have the potential to increase positive brand user imagery directly in the situation where a product purchase can take place, and hence the potential to increase the likelihood of impulse purchasing.

  14. Dynamic Control of Particle Deposition in Evaporating Droplets by an External Point Source of Vapor.

    Science.gov (United States)

    Malinowski, Robert; Volpe, Giovanni; Parkin, Ivan P; Volpe, Giorgio

    2018-02-01

    The deposition of particles on a surface by an evaporating sessile droplet is important for phenomena as diverse as printing, thin-film deposition, and self-assembly. The shape of the final deposit depends on the flows within the droplet during evaporation. These flows are typically determined at the onset of the process by the intrinsic physical, chemical, and geometrical properties of the droplet and its environment. Here, we demonstrate deterministic emergence and real-time control of Marangoni flows within the evaporating droplet by an external point source of vapor. By varying the source location, we can modulate these flows in space and time to pattern colloids on surfaces in a controllable manner.

  15. Developing a Tool Point Control Scheme for a Hydraulic Crane Using Interactive Real-time Dynamic Simulation

    DEFF Research Database (Denmark)

    Pedersen, Mikkel Melters; Hansen, Michael Rygaard; Ballebye, Morten

    2010-01-01

    This paper describes the implementation of an interactive real-time dynamic simulation model of a hydraulic crane. The user input to the model is given continuously via joystick and output is presented continuously in a 3D animation. Using this simulation model, a tool point control scheme...... is developed for the specific crane, considering the saturation phenomena of the system and practical implementation....

  16. Depression treatment for impoverished mothers by point-of-care providers: A randomized controlled trial.

    Science.gov (United States)

    Segre, Lisa S; Brock, Rebecca L; O'Hara, Michael W

    2015-04-01

    Depression in low-income, ethnic-minority women of childbearing age is prevalent and compromises infant and child development. Yet numerous barriers prevent treatment delivery. Listening Visits (LV), an empirically supported intervention developed for delivery by British home-visiting nurses, could address this unmet mental health need. This randomized controlled trial (RCT) evaluated the effectiveness of LV delivered at a woman's usual point-of-care, including home visits or an ob-gyn office. Listening Visits were delivered to depressed pregnant women or mothers of young children by their point-of-care provider (e.g., home visitor or physician's assistant), all of whom had low levels of prior counseling experience. Three quarters of the study's participants were low-income. Of those who reported ethnicity, all identified themselves as minorities. Participants from 4 study sites (N = 66) were randomized in a 2:1 ratio, to LV or a wait-list control group (WLC). Assessments, conducted at baseline and 8 weeks, evaluated depression, quality of life, and treatment satisfaction. Depressive severity, depressive symptoms, and quality of life significantly improved among LV recipients as compared with women receiving standard social/health services. Women valued LV as evidenced by their high attendance rates and treatment satisfaction ratings. In a stepped model of depression care, LV can provide an accessible, acceptable, and effective first-line treatment option for at-risk women who otherwise are unlikely to receive treatment. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  17. A Novel Maximum Power Point Tracking Control for Permanent Magnet Direct Drive Wind Energy Conversion Systems

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2012-05-01

    Full Text Available This paper proposes a novel optimal current given (OCG maximum power point tracking (MPPT control strategy based on the theory of power feedback and hill climb searching (HCS for a permanent magnet direct drive wind energy conversion system (WECS. The presented strategy not only has the advantages of not needing the wind speed and wind turbine characteristics of the traditional HCS method, but it also improves the stability and accuracy of MPPT by estimating the exact loss torque. The OCG MPPT control strategy is first carried out by simulation, then an experimental platform based on the dSPACE1103 controller is built and a 5.5 kW permanent magnet synchronous generator (PMSG is tested. Furthermore, the proposed method is compared experimentally with the traditional optimum tip speed ratio (TSR MPPT control. The experiments verify the effectiveness of the proposed OCG MPPT strategy and demonstrate its better performance than the traditional TSR MPPT control.

  18. Development of a High Temperature Antenna Pointing Mechanism for BepiColombo Planetary Orbiter

    Science.gov (United States)

    Campo, Pablo; Barrio, Aingeru; Puente, Nicolas; Kyle, Robert

    2013-09-01

    BepiColombo is an ESA mission to Mercury its planetary orbiter (MPO) has two antenna pointing mechanism, High gain antenna pointing mechanism steers and points a large reflector which is integrated at system level by TAS-I Rome. Medium gain antenna (MGA) APM points a 1.5 m boom with a horn antenna. Both radiating elements exposed to sun fluxes as high as 10 solar constants without protections.The pointing mechanism is a major challenge as high performances are required in a harsh environment. It has required the development of new technologies, and components specially dedicated for the mission needs. Some of the state of the art required for the mission was achieved during the preparatory technology development activities [1]. However the number of critical elements involved, and the difficulties of some areas have required the continuation of the developments, and new research activities had to be launched in CD phase. Some of the major concerns and related areas of development are:- High temperature and long life requirements for the gearhead motors (up to 15500 equivalent APM revolutions, 19 million motor revolution)- Low thermal distortion of the mechanical chain, being at the same time insulating from external environment and interfaces (55 arcsec pointing error)- Low heat leak to the spacecraft (in the order of 50W per APM)- High precision position control, low microvibration noise and error stability in motion (16 arcsec/s)- High power radio frequency (18W in band Ka, 30 in X band) with phase stability for use in radio-science (3mm in Ka band, 5o in X band).- Wide range of motion (full 360o with end-stops)Currently HGA APM EQM azimuth and elevation stages are assembled and ready for test at actuator level.

  19. Contingent Valuation of Residents' Attitudes and Willingness-to-Pay for Non-point Source Pollution Control: A Case Study in AL-Prespa, Southeastern Albania

    Science.gov (United States)

    Grazhdani, Dorina

    2015-07-01

    Recently, local governments in Albania have begun paying attention to management of small watershed, because there are specific boundaries and people living within a watershed basin tend to be more concerned about the basin's environmental, economic, and social development. But this natural resource management and non-point source (NPS) pollution control is still facing challenges. Albanian part of Prespa Park (AL-Prespa) is a good case study, as it is a protected wetland area of high biodiversity and long human history. In this framework, this study was undertaken, the main objectives of which were to explore: (1) the attitudes of the residents toward NPS pollution control, (2) their willingness-to-pay for improving water quality, and (3) factors affecting the residents' willingness-to-pay. Descriptive statistics, one-way ANOVA (analysis of variance), Chi-square analysis, and multivariate data analysis techniques were used. Findings strongly suggested that the residents' attitudes toward NPS pollution control in this area were positive. With the combination of two major contingent valuation methods—dichotomous choice and open-ended formats, the survey results indicated that the average yearly respondents' WTP was €6.4. The survey revealed that residents' yearly income and education level were the main factors affecting residents' willingness-to-pay for NPS pollution control in this area, and there was no significant correlation between residents' yearly income and their education level. The current study would lay a solid foundation on decision-making in further NPS pollution control and public participation through community-based watershed management policies in AL-Prespa watershed and similar areas.

  20. Sliding Mode Extremum Seeking Control Scheme Based on PSO for Maximum Power Point Tracking in Photovoltaic Systems

    Directory of Open Access Journals (Sweden)

    Her-Terng Yau

    2013-01-01

    Full Text Available An extremum seeking control (ESC scheme is proposed for maximum power point tracking (MPPT in photovoltaic power generation systems. The robustness of the proposed scheme toward irradiance changes is enhanced by implementing the ESC scheme using a sliding mode control (SMC law. In the proposed approach, the chattering phenomenon caused by high frequency switching is suppressed by means of a sliding layer concept. Moreover, in implementing the proposed controller, the optimal value of the gain constant is determined using a particle swarm optimization (PSO algorithm. The experimental and simulation results show that the proposed PSO-based sliding mode ESC (SMESC control scheme yields a better transient response, steady-state stability, and robustness than traditional MPPT schemes based on gradient detection methods.

  1. Is blunted cardiovascular reactivity in depression mood-state dependent? A comparison of major depressive disorder remitted depression and healthy controls.

    Science.gov (United States)

    Salomon, Kristen; Bylsma, Lauren M; White, Kristi E; Panaite, Vanessa; Rottenberg, Jonathan

    2013-10-01

    Prior work has repeatedly demonstrated that people who have current major depression exhibit blunted cardiovascular reactivity to acute stressors (e.g., Salomon et al., 2009). A key question regards the psychobiological basis for these deficits, including whether such deficits are depressed mood-state dependent or whether these effects are trait-like and are observed outside of depression episodes in vulnerable individuals. To examine this issue, we assessed cardiovascular reactivity to a speech stressor task and a forehead cold pressor in 50 individuals with current major depressive disorder (MDD), 25 with remitted major depression (RMD), and 45 healthy controls. Heart rate (HR), blood pressure and impedance cardiography were assessed and analyses controlled for BMI and sex. Significant group effects were found for SBP, HR, and PEP for the speech preparation period and HR, CO, and PEP during the speech. For each of these parameters, only the MDD group exhibited attenuated reactivity as well as impaired SBP recovery. Reactivity and recovery in the RMD group more closely resembled the healthy controls. Speeches given by the MDD group were rated as less persuasive than the RMD or healthy controls' speeches. No significant differences were found for the cold pressor. Blunted cardiovascular reactivity and impaired recovery in current major depression may be mood-state dependent phenomena and may be more reflective of motivational deficits than deficits in the physiological integrity of the cardiovascular system. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Active control of sound transmission through a rectangular panel using point-force actuators and piezoelectric film sensors.

    Science.gov (United States)

    Sanada, Akira; Higashiyama, Kouji; Tanaka, Nobuo

    2015-01-01

    This study deals with the active control of sound transmission through a rectangular panel, based on single input, single output feedforward vibration control using point-force actuators and piezoelectric film sensors. It focuses on the phenomenon in which the sound power transmitted through a finite-sized panel drops significantly at some frequencies just below the resonance frequencies of the panel in the low-frequency range as a result of modal coupling cancellation. In a previous study, it was shown that when point-force actuators are located on nodal lines for the frequency at which this phenomenon occurs, a force equivalent to the incident sound wave can act on the panel. In this study, a practical method for sensing volume velocity using a small number of piezoelectric film strips is investigated. It is found that two quadratically shaped piezoelectric film strips, attached at the same nodal lines as those where the actuators were placed, can sense the volume velocity approximately in the low-frequency range. Results of simulations show that combining the proposed actuation method and the sensing method can achieve a practical control effect at low frequencies over a wide frequency range. Finally, experiments are carried out to demonstrate the validity and feasibility of the proposed method.

  3. Hazard analysis of critical control points assessment as a tool to respond to emerging infectious disease outbreaks.

    Directory of Open Access Journals (Sweden)

    Kelly L Edmunds

    Full Text Available Highly pathogenic avian influenza virus (HPAI strain H5N1 has had direct and indirect economic impacts arising from direct mortality and control programmes in over 50 countries reporting poultry outbreaks. HPAI H5N1 is now reported as the most widespread and expensive zoonotic disease recorded and continues to pose a global health threat. The aim of this research was to assess the potential of utilising Hazard Analysis of Critical Control Points (HACCP assessments in providing a framework for a rapid response to emerging infectious disease outbreaks. This novel approach applies a scientific process, widely used in food production systems, to assess risks related to a specific emerging health threat within a known zoonotic disease hotspot. We conducted a HACCP assessment for HPAI viruses within Vietnam's domestic poultry trade and relate our findings to the existing literature. Our HACCP assessment identified poultry flock isolation, transportation, slaughter, preparation and consumption as critical control points for Vietnam's domestic poultry trade. Introduction of the preventative measures highlighted through this HACCP evaluation would reduce the risks posed by HPAI viruses and pressure on the national economy. We conclude that this HACCP assessment provides compelling evidence for the future potential that HACCP analyses could play in initiating a rapid response to emerging infectious diseases.

  4. Repeated tender point injections of granisetron alleviate chronic myofascial pain--a randomized, controlled, double-blinded trial.

    Science.gov (United States)

    Christidis, Nikolaos; Omrani, Shahin; Fredriksson, Lars; Gjelset, Mattias; Louca, Sofia; Hedenberg-Magnusson, Britt; Ernberg, Malin

    2015-01-01

    Serotonin (5-HT) mediates pain by peripheral 5-HT3-receptors. Results from a few studies indicate that intramuscular injections of 5-HT3-antagonists may reduce musculoskeletal pain. The aim of this study was to investigate if repeated intramuscular tender-point injections of the 5-HT3-antagonist granisetron alleviate pain in patients with myofascial temporomandibular disorders (M-TMD). This prospective, randomized, controlled, double blind, parallel-arm trial (RCT) was carried out during at two centers in Stockholm, Sweden. The randomization was performed by a researcher who did not participate in data collection with an internet-based application ( www.randomization.com ). 40 patients with a diagnose of M-TMD according to the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) were randomized to receive repeated injections, one week apart, with either granisetron (GRA; 3 mg) or isotonic saline as control (CTR). The median weekly pain intensities decreased significantly at all follow-ups (1-, 2-, 6-months) in the GRA-group (Friedman test; P  0.075). The numbers needed to treat (NNT) were 4 at the 1- and 6-month follow-ups, and 3.3 at the 2-month follow-up in favor of granisetron. Repeated intramuscular tender-point injections with granisetron provide a new pharmacological treatment possibility for myofascial pain patients with repeated intramuscular tender-point injections with the serotonin type 3 antagonist granisetron. It showed a clinically relevant pain reducing effect in the temporomandibular region, both in a short- and long-term aspect. European Clinical Trials Database 2005-006042-41 as well as at Clinical Trials NCT02230371 .

  5. N-acetylcysteine for major mental disorders: a systematic review and meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Zheng, W; Zhang, Q-E; Cai, D-B; Yang, X-H; Qiu, Y; Ungvari, G S; Ng, C H; Berk, M; Ning, Y-P; Xiang, Y-T

    2018-05-01

    This systematic review and meta-analysis of randomized controlled trials (RCTs) examined the efficacy and safety of adjunctive N-acetylcysteine (NAC), an antioxidant drug, in treating major depressive disorder (MDD), bipolar disorder, and schizophrenia. The PubMed, Cochrane Library, PsycINFO, CNKI, CBM, and WanFang databases were independently searched and screened by two researchers. Standardized mean differences (SMDs), risk ratios, and their 95% confidence intervals (CIs) were computed. Six RCTs (n = 701) of NAC for schizophrenia (three RCTs, n = 307), bipolar disorder (two RCTs, n = 125), and MDD (one RCT, n = 269) were identified and analyzed as separate groups. Adjunctive NAC significantly improved total psychopathology (SMD = -0.74, 95% CI: -1.43, -0.06; I 2 = 84%, P = 0.03) in schizophrenia, but it had no significant effect on depressive and manic symptoms as assessed by the Young Mania Rating Scale in bipolar disorder and only a small effect on major depressive symptoms. Adverse drug reactions to NAC and discontinuation rates between the NAC and control groups were similar across the three disorders. Adjunctive NAC appears to be a safe treatment that has efficacy for schizophrenia, but not for bipolar disorder or MDD. Further higher quality RCTs are warranted to determine the role of adjunctive NAC in the treatment of major psychiatric disorders. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Modeling route choice criteria from home to major streets: A discrete choice approach

    Directory of Open Access Journals (Sweden)

    Jose Osiris Vidana-Bencomo

    2018-03-01

    Full Text Available A discrete choice model that consists of three sub-models was developed to investigates the route choice criteria of drivers who travel from their homes in the morning to the access point along the major streets that bound the Traffic Analysis Zones (TAZs. The first sub-model is a Nested Logit Model (NLM that estimates the probability of a driver has or has no multiple routes, and if the driver has multiple routes, the route selection criteria are based on the access point’s intersection control type or other factors. The second sub-model is a Mixed Logit (MXL model. It estimates the probabilities of the type of intersection control preferred by a driver. The third sub-model is a NLM that estimates the probabilities of a driver selecting his/her route for its shortest travel time or to avoid pedestrian, and if the aim is to take the fastest route, the decision criteria is based on the shortest distance or minimum stops and turns. Data gathered in a questionnaire survey were used to estimate the sub-models. The attributes of the utility functions of the sub-models are the driver’s demographic and trip characteristics. The model provides a means for transportation planners to distribute the total number of home-based trips generated within a TAZ to the access points along the major streets that bound the TAZ.

  7. Neural Modeling of Fuzzy Controllers for Maximum Power Point Tracking in Photovoltaic Energy Systems

    Science.gov (United States)

    Lopez-Guede, Jose Manuel; Ramos-Hernanz, Josean; Altın, Necmi; Ozdemir, Saban; Kurt, Erol; Azkune, Gorka

    2018-06-01

    One field in which electronic materials have an important role is energy generation, especially within the scope of photovoltaic energy. This paper deals with one of the most relevant enabling technologies within that scope, i.e, the algorithms for maximum power point tracking implemented in the direct current to direct current converters and its modeling through artificial neural networks (ANNs). More specifically, as a proof of concept, we have addressed the problem of modeling a fuzzy logic controller that has shown its performance in previous works, and more specifically the dimensionless duty cycle signal that controls a quadratic boost converter. We achieved a very accurate model since the obtained medium squared error is 3.47 × 10-6, the maximum error is 16.32 × 10-3 and the regression coefficient R is 0.99992, all for the test dataset. This neural implementation has obvious advantages such as a higher fault tolerance and a simpler implementation, dispensing with all the complex elements needed to run a fuzzy controller (fuzzifier, defuzzifier, inference engine and knowledge base) because, ultimately, ANNs are sums and products.

  8. Optical tools and techniques for aligning solar payloads with the SPARCS control system. [Solar Pointing Aerobee Rocket Control System

    Science.gov (United States)

    Thomas, N. L.; Chisel, D. M.

    1976-01-01

    The success of a rocket-borne experiment depends not only on the pointing of the attitude control system, but on the alignment of the attitude control system to the payload. To ensure proper alignment, special optical tools and alignment techniques are required. Those that were used in the SPARCS program are described and discussed herein. These tools include theodolites, autocollimators, a 38-cm diameter solar simulator, a high-performance 1-m heliostat to provide a stable solar source during the integration of the rocket payload, a portable 75-cm sun tracker for use at the launch site, and an innovation called the Solar Alignment Prism. Using the real sun as the primary reference under field conditions, the Solar Alignment Prism facilitates the coalignment of the attitude sun sensor with the payload. The alignment techniques were developed to ensure the precise alignment of the solar payloads to the SPARCS attitude sensors during payload integration and to verify the required alignment under field conditions just prior to launch.

  9. Children with migraine: Provocation of headache via pressure to myofascial trigger points in the trapezius muscle? - A prospective controlled observational study.

    Science.gov (United States)

    Landgraf, M N; Biebl, J T; Langhagen, T; Hannibal, I; Eggert, T; Vill, K; Gerstl, L; Albers, L; von Kries, R; Straube, A; Heinen, F

    2018-02-01

    The objective was to evaluate a supposed clinical interdependency of myofascial trigger points and migraine in children. Such interdependency would support an interaction of spinal and trigeminal afferences in the trigemino-cervical complex as a contributing factor in migraine. Children ≤18 years with the confirmed diagnosis of migraine were prospectively investigated. Comprehensive data on medical history, clinical neurological and psychological status were gathered. Trigger points in the trapezius muscle were identified by palpation and the threshold of pressure pain at these points was measured. Manual pressure was applied to the trigger points, and the occurrence and duration of induced headache were recorded. At a second consultation (4 weeks after the first), manual pressure with the detected pressure threshold was applied to non-trigger points within the same trapezius muscle (control). Headache and related parameters were again recorded and compared to the results of the first consultation. A total of 13 girls and 13 boys with migraine and a median age of 14.5 (Range 6.3-17.8) years took part in the study. Manual pressure to trigger points in the trapezius muscle led to lasting headache after termination of the manual pressure in 13 patients while no patient experienced headache when manual pressure was applied to non-trigger points at the control visit (p complex, especially in adolescents. In children with migraine headache can often be induced by pressure to myofascial trigger points, but not by pressure to non-trigger points in the trapezius muscle. This supports the hypothesis of a trigemino-cervical-complex in the pathophysiology of migraine, which might have implications for innovative therapies in children with migraine. © 2017 European Pain Federation - EFIC®.

  10. Improved point-kinetics model for the BWR control rod drop accident

    International Nuclear Information System (INIS)

    Neogy, P.; Wakabayashi, T.; Carew, J.F.

    1985-01-01

    A simple prescription to account for spatial feedback weighting effects in RDA (rod drop accident) point-kinetics analyses has been derived and tested. The point-kinetics feedback model is linear in the core peaking factor, F/sub Q/, and in the core average void fraction and fuel temperature. Comparison with detailed spatial kinetics analyses indicates that the improved point-kinetics model provides an accurate description of the BWR RDA

  11. Public Support for Family Smoking Prevention and Tobacco Control Act Point-of-Sale Provisions: Results of a National Study.

    Science.gov (United States)

    Rose, Shyanika W; Emery, Sherry L; Ennett, Susan; McNaughton Reyes, Heath Luz; Scott, John C; Ribisl, Kurt M

    2015-10-01

    We assessed public and smoker support for enacted and potential point-of-sale (POS) tobacco-control policies under the Family Smoking Prevention and Tobacco Control Act. We surveyed a US nationally representative sample of 17, 507 respondents (6595 smokers) in January through February 2013, and used linear regression to calculate weighted point estimates and identify factors associated with support for POS policies among adults and smokers. Overall, nonsmokers were more supportive than were smokers. Regardless of smoking status, African Americans, Hispanics, women, and those of older ages were more supportive than White, male, and younger respondents, respectively. Policy support varied by provision. More than 80% of respondents supported minors' access restrictions and more than 45% supported graphic warnings. Support was lowest for plain packaging (23%), black-and-white advertising (26%), and a ban on menthol cigarettes (36%). Public support for marketing and POS provisions is low relative to other areas of tobacco control. Tobacco-control advocates and the Food and Drug Administration should build on existing levels of public support to promote and maintain evidence-based, but controversial, policy changes in the retail environment.

  12. Measuring the distance from saddle points and driving to locate them over quantum control landscapes

    International Nuclear Information System (INIS)

    Sun, Qiuyang; Riviello, Gregory; Rabitz, Herschel; Wu, Re-Bing

    2015-01-01

    Optimal control of quantum phenomena involves the introduction of a cost functional J to characterize the degree of achieving a physical objective by a chosen shaped electromagnetic field. The cost functional dependence upon the control forms a control landscape. Two theoretically important canonical cases are the landscapes associated with seeking to achieve either a physical observable or a unitary transformation. Upon satisfaction of particular assumptions, both landscapes are analytically known to be trap-free, yet possess saddle points at precise suboptimal J values. The presence of saddles on the landscapes can influence the effort needed to find an optimal field. As a foundation to future algorithm development and analyzes, we define metrics that identify the ‘distance’ from a given saddle based on the sufficient and necessary conditions for the existence of the saddles. Algorithms are introduced utilizing the metrics to find a control such that the dynamics arrive at a targeted saddle. The saddle distance metric and saddle-seeking methodology is tested numerically in several model systems. (paper)

  13. Natural gas treatment: Simultaneous water and hydrocarbon-dew point-control

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, T. (Solvay Catalysts GmbH, Hannover (Germany)); Rennemann, D. (Solvay Catalysts GmbH, Hannover (Germany)); Schulz, T. (Solvay Catalysts GmbH, Hannover (Germany))

    1993-10-01

    Natural gas is a multicomponent mixture of hydrocarbons. The condensation behavior of such mixtures is different from single component systems. The so-called retrograde behavior leads to the observations that saturated vapor (dew point curve) and saturated liquid curve (bubble point curve) are not identical. Between both is a region of saturated phases which even can exist above the critical point. Following this behaviour it is possible that condensation might occur at pressure decrease or at temperature increase, respectively. This phenomenon is undesired in natural gas pipeline networks. Selective removal of higher hydrocarbons by the means of adsorption can change the phase behavior in such a way that condensation does not occur at temperatures and pressures specified for gas distribution. (orig.)

  14. Comparison of right and left side heart functions in patients with thalassemia major, patients with thalassemia intermedia, and control group.

    Science.gov (United States)

    Noori, Noormohammad; Mohamadi, Mehdi; Keshavarz, Kambiz; Alavi, Seyed Mostafa; Mahjoubifard, Maziar; Mirmesdagh, Yalda

    2013-01-01

    Heart disease is the main cause of mortality and morbidity in patients with beta thalassemia, rendering its early diagnosis vital. We studied and compared echocardiographic findings in patients with beta thalassemia major, patients with beta thalassemia intermedia, and a control group. Eighty asymptomatic patients with thalassemia major and 22 asymptomatic cases with thalassemia intermedia (8-25 years old) were selected from those referred to Ali Asghar Hospital (Zahedan-Iran) between June 2008 and June 2009. Additionally, 80 healthy individuals within the same age and sex groups were used as controls. All the individuals underwent echocardiography, the data of which were analyzed with the Student t-test. The mean value of the pre-ejection period/ejection time ratio of the left ventricle during systole, the diameter of the posterior wall of the left ventricle during diastole, the left and right isovolumic relaxation times, and the right myocardial performance index in the patients with beta thalassemia major and intermedia increased significantly compared to those of the controls, but the other parameters were similar between the two patient groups. The mean values of the left and right pre-ejection periods, left ventricular end systolic dimension, and left isovolumic contraction time in the patients with thalassemia intermedia increased significantly compared to those of the controls. In the left side, myocardial performance index, left ventricular mass index, isovolumic contraction time, and deceleration time exhibited significant changes between the patients with thalassemia major and those with thalassemia intermedia, whereas all the echocardiographic parameters of the right side were similar between these two groups. The results showed that the systolic and diastolic functions of the right and left sides of the heart would be impaired in patients with thalassemia major and thalassemia intermedia. Consequently, serial echocardiography is suggested in

  15. Major Causes of Organizational Conflict: Diagnosis for Action. Working Paper.

    Science.gov (United States)

    Derr, C. Brooklyn

    Six major causes of organizational conflict (individual stress, role conflict, power struggles, differentiation, interdependence, and external pressures) are delineated; implications for managing these conflicts using collaboration, bargaining, and power plays are pointed out; a conflict management paradigm pointing out which mode of conflict…

  16. Different genetic control of cutaneous and visceral disease after Leishmania major infection in mice

    Czech Academy of Sciences Publication Activity Database

    Vladimirov, Vladimir; Badalová, Jana; Svobodová, M.; Havelková, Helena; Hart, A. A. M.; Blažková, Hana; Demant, P.; Lipoldová, Marie

    2003-01-01

    Roč. 71, č. 4 (2003), s. 2041-2046 ISSN 0019-9567 R&D Projects: GA ČR GA310/00/0760; GA ČR GA310/03/1381; GA MŠk OK 394 Grant - others:Howard Hughes Medical Institute(US) HHMI55000323; EC(XE) ERBI-C15-CT98-0317; EC(XE) BIO-4-CT98-0445 Institutional research plan: CEZ:AV0Z5052915 Keywords : genetic control * Leishmania major Subject RIV: EC - Immunology Impact factor: 3.875, year: 2003

  17. Spline Trajectory Algorithm Development: Bezier Curve Control Point Generation for UAVs

    Science.gov (United States)

    Howell, Lauren R.; Allen, B. Danette

    2016-01-01

    A greater need for sophisticated autonomous piloting systems has risen in direct correlation with the ubiquity of Unmanned Aerial Vehicle (UAV) technology. Whether surveying unknown or unexplored areas of the world, collecting scientific data from regions in which humans are typically incapable of entering, locating lost or wanted persons, or delivering emergency supplies, an unmanned vehicle moving in close proximity to people and other vehicles, should fly smoothly and predictably. The mathematical application of spline interpolation can play an important role in autopilots' on-board trajectory planning. Spline interpolation allows for the connection of Three-Dimensional Euclidean Space coordinates through a continuous set of smooth curves. This paper explores the motivation, application, and methodology used to compute the spline control points, which shape the curves in such a way that the autopilot trajectory is able to meet vehicle-dynamics limitations. The spline algorithms developed used to generate these curves supply autopilots with the information necessary to compute vehicle paths through a set of coordinate waypoints.

  18. A Unified Point Process Probabilistic Framework to Assess Heartbeat Dynamics and Autonomic Cardiovascular Control

    Directory of Open Access Journals (Sweden)

    Zhe eChen

    2012-02-01

    Full Text Available In recent years, time-varying inhomogeneous point process models have been introduced for assessment of instantaneous heartbeat dynamics as well as specific cardiovascular control mechanisms and hemodynamics. Assessment of the model's statistics is established through the Wiener-Volterra theory and a multivariate autoregressive (AR structure. A variety of instantaneous cardiovascular metrics, such as heart rate (HR, heart rate variability (HRV, respiratory sinus arrhythmia (RSA, and baroreceptor-cardiac reflex (baroreflex sensitivity (BRS, are derived within a parametric framework and instantaneously updated with adaptive and local maximum likelihood estimation algorithms. Inclusion of second order nonlinearities, with subsequent bispectral quantification in the frequency domain, further allows for definition of instantaneous metrics of nonlinearity. We here organize a comprehensive review of the devised methods as applied to experimental recordings from healthy subjects during propofol anesthesia. Collective results reveal interesting dynamic trends across the different pharmacological interventions operated within each anesthesia session, confirming the ability of the algorithm to track important changes in cardiorespiratory elicited interactions, and pointing at our mathematical approach as a promising monitoring tool for an accurate, noninvasive assessment in clinical practice.

  19. Professional SharePoint 2010 Cloud-Based Solutions

    CERN Document Server

    Fox, Steve; Stubbs, Paul; Follette, Donovan

    2011-01-01

    An authoritative guide to extending SharePoint's power with cloud-based services If you want to be part of the next major shift in the IT industry, you'll want this book. Melding two of the hottest trends in the industry—the widespread popularity of the SharePoint collaboration platform and the rapid rise of cloud computing—this practical guide shows developers how to extend their SharePoint solutions with the cloud's almost limitless capabilities. See how to get started, discover smart ways to leverage cloud data and services through Azure, start incorporating Twitter or LinkedIn

  20. EBTR design-point selection

    International Nuclear Information System (INIS)

    Krakowski, R.A.; Bathke, C.G.

    1981-01-01

    The procedure used to select the design point for the ELMO Bumpy Torus Reactor (EBTR) study is described. The models used in each phase of the selection process are described, with an emphasis placed on the parametric design curves produced by each model. The tradeoffs related to burn physics, stability/equilibrium, electron-ring physics, and magnetics design are discussed. The resulting design point indicates a plasma with a 35-m major radius and a 1-m minor radium operating at an average core-plasma beta of 0.17, which at approx. 30 keV produces an average neutron wall loading of 1.4 MW/m 2 while maintaining key magnet (< 10 T) and total power (less than or equal to 4000 MWt) constraints

  1. Major factors controlling fracture development in the Middle Permian Lucaogou Formation tight oil reservoir, Junggar Basin, NW China

    Science.gov (United States)

    Zhang, Chen; Zhu, Deyu; Luo, Qun; Liu, Luofu; Liu, Dongdong; Yan, Lin; Zhang, Yunzhao

    2017-09-01

    Natural fractures in seven wells from the Middle Permian Lucaogou Formation in the Junggar Basin were evaluated in light of regional structural evolution, tight reservoir geochemistry (including TOC and mineral composition), carbon and oxygen isotopes of calcite-filled fractures, and acoustic emission (AE). Factors controlling the development of natural fractures were analyzed using qualitative and/or semi-quantitative techniques, with results showing that tectonic factors are the primary control on fracture development in the Middle Permian Lucaogou Formation of the Junggar Basin. Analyses of calcite, dolomite, and TOC show positive correlations with the number of fractures, while deltaic lithofacies appear to be the most favorable for fracture development. Mineral content was found to be a major control on tectonic fracture development, while TOC content and sedimentary facies mainly control bedding fractures. Carbon and oxygen isotopes vary greatly in calcite-filled fractures (δ13C ranges from 0.87‰ to 7.98‰, while δ18O ranges from -12.63‰ to -5.65‰), indicating that fracture development increases with intensified tectonic activity or enhanced diagenetic alteration. By analyzing the cross-cutting relationships of fractures in core, as well as four Kaiser Effect points in the acoustic emission curve, we observed four stages of tectonic fracture development. First-stage fractures are extensional, and were generated in the late Triassic, with calcite fracture fills formed between 36.51 °C and 56.89 °C. Second-stage fractures are shear fractures caused by extrusion stress from the southwest to the northeast, generated by the rapid uplift of the Tianshan in the Middle and Late Jurassic; calcite fracture fills formed between 62.91 °C and 69.88 °C. Third-stage fractures are NNW-trending shear fractures that resulted from north-south extrusion and thrusting in a foreland depression along the front of the Early Cretaceous Bogda Mountains. Calcite fracture

  2. Development of hazard analysis by critical control points (HACCP) procedures to control organic chemical hazards in the agricultural production of raw food commodities.

    Science.gov (United States)

    Ropkins, Karl; Ferguson, Andrew; Beck, Angus J

    2003-01-01

    Hazard Analysis by Critical Control Points (HACCP) is a systematic approach to the identification, assessment, and control of hazards in the food chain. Effective HACCP requires the consideration of all chemical microbiological, and physical hazards. However, current procedures focus primarily on microbiological and physical hazards, while chemical aspects of HACCP have received relatively little attention. In this article we discuss the application of HACCP to organic chemical contaminants and the problems that are likely to be encountered in agriculture. We also present generic templates for the development of organic chemical contaminant HACCP procedures for selected raw food commodities, that is, cereal crops,raw meats, and milk.

  3. Evolution of Motor Control: From Reflexes and Motor Programs to the Equilibrium-Point Hypothesis.

    Science.gov (United States)

    Latash, Mark L

    2008-01-01

    This brief review analyzes the evolution of motor control theories along two lines that emphasize active (motor programs) and reactive (reflexes) features of voluntary movements. It suggests that the only contemporary hypothesis that integrates both approaches in a fruitful way is the equilibrium-point hypothesis. Physical, physiological, and behavioral foundations of the EP-hypothesis are considered as well as relations between the EP-hypothesis and the recent developments of the notion of motor synergies. The paper ends with a brief review of the criticisms of the EP-hypothesis and challenges that the hypothesis faces at this time.

  4. Influencing Factors of the Initiation Point in the Parachute-Bomb Dynamic Detonation System

    Science.gov (United States)

    Qizhong, Li; Ye, Wang; Zhongqi, Wang; Chunhua, Bai

    2017-12-01

    The parachute system has been widely applied in modern armament design, especially for the fuel-air explosives. Because detonation of fuel-air explosives occurs during flight, it is necessary to investigate the influences of the initiation point to ensure successful dynamic detonation. In fact, the initiating position exist the falling area in the fuels, due to the error of influencing factors. In this paper, the major influencing factors of initiation point were explored with airdrop and the regularity between initiation point area and factors were obtained. Based on the regularity, the volume equation of initiation point area was established to predict the range of initiation point in the fuel. The analysis results showed that the initiation point appeared area, scattered on account of the error of attitude angle, secondary initiation charge velocity, and delay time. The attitude angle was the major influencing factors on a horizontal axis. On the contrary, secondary initiation charge velocity and delay time were the major influencing factors on a horizontal axis. Overall, the geometries of initiation point area were sector coupled with the errors of the attitude angle, secondary initiation charge velocity, and delay time.

  5. Application of Hazard Analysis and Critical Control Points (HACCP) to the Cultivation Line of Mushroom and Other Cultivated Edible Fungi.

    Science.gov (United States)

    Pardo, José E; de Figueirêdo, Vinícius Reis; Alvarez-Ortí, Manuel; Zied, Diego C; Peñaranda, Jesús A; Dias, Eustáquio Souza; Pardo-Giménez, Arturo

    2013-09-01

    The Hazard analysis and critical control points (HACCP) is a preventive system which seeks to ensure food safety and security. It allows product protection and correction of errors, improves the costs derived from quality defects and reduces the final overcontrol. In this paper, the system is applied to the line of cultivation of mushrooms and other edible cultivated fungi. From all stages of the process, only the reception of covering materials (stage 1) and compost (stage 3), the pre-fruiting and induction (step 6) and the harvest (stage 7) have been considered as critical control point (CCP). The main hazards found were the presence of unauthorized phytosanitary products or above the permitted dose (stages 6 and 7), and the presence of pathogenic bacteria (stages 1 and 3) and/or heavy metals (stage 3). The implementation of this knowledge will allow the self-control of their productions based on the system HACCP to any plant dedicated to mushroom or other edible fungi cultivation.

  6. The boiling point of stratospheric aerosols.

    Science.gov (United States)

    Rosen, J. M.

    1971-01-01

    A photoelectric particle counter was used for the measurement of aerosol boiling points. The operational principle involves raising the temperature of the aerosol by vigorously heating a portion of the intake tube. At or above the boiling point, the particles disintegrate rather quickly, and a noticeable effect on the size distribution and concentration is observed. Stratospheric aerosols appear to have the same volatility as a solution of 75% sulfuric acid. Chemical analysis of the aerosols indicates that there are other substances present, but that the sulfate radical is apparently the major constituent.

  7. First Results of a Tandem Terrestrial-Unmanned Aerial mapKITE System with Kinematic Ground Control Points for Corridor Mapping

    Directory of Open Access Journals (Sweden)

    Pere Molina

    2017-01-01

    Full Text Available In this article, we report about the first results of the mapKITE system, a tandem terrestrial-aerial concept for geodata acquisition and processing, obtained in corridor mapping missions. The system combines an Unmanned Aerial System (UAS and a Terrestrial Mobile Mapping System (TMMS operated in a singular way: real-time waypoints are computed from the TMMS platform and sent to the UAS in a follow-me scheme. This approach leads to a simultaneous acquisition of aerial-plus-ground geodata and, moreover, opens the door to an advanced post-processing approach for sensor orientation. The current contribution focuses on analysing the impact of the new, dynamic Kinematic Ground Control Points (KGCPs, which arise inherently from the mapKITE paradigm, as an alternative to conventional, costly Ground Control Points (GCPs. In the frame of a mapKITE campaign carried out in June 2016, we present results entailing sensor orientation and calibration accuracy assessment through ground check points, and precision and correlation analysis of self-calibration parameters’ estimation. Conclusions indicate that the mapKITE concept eliminates the need for GCPs when using only KGCPs plus a couple of GCPs at each corridor end, achieving check point horizontal accuracy of μ E , N ≈ 1.7 px (3.4 cm and μ h ≈ 4.3 px (8.6 cm. Since obtained from a simplified version of the system, these preliminary results are encouraging from a future perspective.

  8. Intelligent Photovoltaic Maximum Power Point Tracking Controller for Energy Enhancement in Renewable Energy System

    Directory of Open Access Journals (Sweden)

    Subiyanto

    2013-01-01

    Full Text Available Photovoltaic (PV system is one of the promising renewable energy technologies. Although the energy conversion efficiency of the system is still low, but it has the advantage that the operating cost is free, very low maintenance and pollution-free. Maximum power point tracking (MPPT is a significant part of PV systems. This paper presents a novel intelligent MPPT controller for PV systems. For the MPPT algorithm, an optimized fuzzy logic controller (FLC using the Hopfield neural network is proposed. It utilizes an automatically tuned FLC membership function instead of the trial-and-error approach. The MPPT algorithm is implemented in a new variant of coupled inductor soft switching boost converter with high voltage gain to increase the converter output from the PV panel. The applied switching technique, which includes passive and active regenerative snubber circuits, reduces the insulated gate bipolar transistor switching losses. The proposed MPPT algorithm is implemented using the dSPACE DS1104 platform software on a DS1104 board controller. The prototype MPPT controller is tested using an agilent solar array simulator together with a 3 kW real PV panel. Experimental test results show that the proposed boost converter produces higher output voltages and gives better efficiency (90% than the conventional boost converter with an RCD snubber, which gives 81% efficiency. The prototype MPPT controller is also found to be capable of tracking power from the 3 kW PV array about 2.4 times more than that without using the MPPT controller.

  9. Control points within the cell cycle

    International Nuclear Information System (INIS)

    Van't Hof, J.

    1984-01-01

    Evidence of the temporal order of chromosomal DNA replication argues favorably for the view that the cell cycle is controlled by genes acting in sequence whose time of expression is determined by mitosis and the amount of nuclear DNA (2C vs 4C) in the cell. Gl and G2 appear to be carbohydrate dependent in that cells starved of either carbohydrate of phosphate fail to make these transitions. Cells deprived of nitrate, however, fail only at Gl to S transition indicating that the controls that operate in G1 differ from those that operate in G2. 46 references, 5 figures

  10. Enhanced Buck-Boost Three-Level Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Tan, K. K.; Gao, F.; Chiang Loh, Poh

    2009-01-01

    In traditional three-level neutral-point-clamped (NPC) inverters, a major issue is capacitor voltage imbalance, which results in low order harmonics. The compensation of the capacitor voltages often require additional control complexity, which cannot be conveniently implemented. The "alternative...... phase opposition disposition" (APOD) modulation method used in traditional NPC topologies also has lower harmonics performance as compared to the "phase disposition" (PD) modulation method.In this paper, we introduce a new three-level NPC topology that utilises the harmonically superior PD modulation...... method, with the ability to easily adjust for capacitor voltage imbalances. To further improve the boost capability of the three-level NPC inverters, another new topology introduces 2 additional diodes,achieving higher boost performance while totally eliminating thepossibility of capacitor voltage...

  11. Non-invasive three-dimension control of light between turbid layers using a surface quasi-point light source for precorrection.

    Science.gov (United States)

    Qiao, Mu; Liu, Honglin; Pang, Guanghui; Han, Shensheng

    2017-08-29

    Manipulating light non-invasively through inhomogeneous media is an attractive goal in many disciplines. Wavefront shaping and optical phase conjugation can focus light to a point. Transmission matrix method can control light on multiple output modes simultaneously. Here we report a non-invasive approach which enables three-dimension (3D) light control between two turbid layers. A digital optical phase conjugation mirror measured and conjugated the diffused wavefront, which originated from a quasi-point source on the front turbid layer and passed through the back turbid layer. And then, because of memory effect, the phase-conjugated wavefront could be used as a carrier wave to transport a pre-calculated wavefront through the back turbid layer. The pre-calculated wavefront could project a desired 3D light field inside the sample, which, in our experiments, consisted of two 220-grid ground glass plates spaced by a 20 mm distance. The controllable range of light, according to the memory effect, was calculated to be 80 mrad in solid angle and 16 mm on z-axis. Due to the 3D light control ability, our approach may find applications in photodynamic therapy and optogenetics. Besides, our approach can also be combined with ghost imaging or compressed sensing to achieve 3D imaging between turbid layers.

  12. Defining guilt in depression: a comparison of subjects with major depression, chronic medical illness and healthy controls.

    Science.gov (United States)

    Ghatavi, Kayhan; Nicolson, Rob; MacDonald, Cathy; Osher, Sue; Levitt, Anthony

    2002-04-01

    Although guilt is a widely accepted feature of depression, there is limited and inconsistent data defining the nature of this symptom. The purpose of the current study was to examine the specificity and nature of guilt in subjects with major depression as compared to patients with another chronic medical illness and healthy controls. Outpatients with current major depressive episode (MDE; n=34), past-MDE (n=22), chronic cardiac illness (n=20) and healthy controls (n=59) were administered the following measures: The Guilt Inventory (GI), State Shame and Guilt Scale (SSGS), 17-item Hamilton Rating Scale for Depression (Ham-D) and the Structured Clinical Interview for DSM-IV. Overall multivariate analysis of covariance comparing mean scores for the six guilt subscales [state-guilt, trait-guilt, moral standards (from the GI); state-guilt, -pride, and -shame (from the SSGS)] across the four groups was significant (F=9.1, df=6:121, pguilt (GI), current-MDE>past-MDE>cardiac=healthy controls; for trait-guilt (GI), current-MDE=past-MDE>cardiac=healthy controls; for state-shame, -guilt and -pride (SSGS), current-MDE>past-MDE, past-MDE=cardiac, past-MDE>healthy, cardiac=healthy controls. Among depressed patients, there was significant correlation between Ham-D score and all guilt sub-scales (pguilt, shame and low pride distinguish acutely depressed from all other groups, and are highly influenced by severity of depression. Trait-guilt does not differentiate acute from past depressed. Data suggests guilt may represent both an enduring and fluctuating feature of depressive illness over its longitudinal course.

  13. Identification of hazelnut major allergens in sensitive patients with positive double-blind, placebo-controlled food challenge results

    DEFF Research Database (Denmark)

    Pastorello, Elide A; Vieths, Stefan; Pravettoni, Valerio

    2002-01-01

    The hazelnut major allergens identified to date are an 18-kd protein homologous to Bet v 1 and a 14-kd allergen homologous to Bet v 2. No studies have reported hazelnut allergens recognized in patients with positive double-blind, placebo-controlled food challenge (DBPCFC) results or in patients...

  14. Intelligent approach to maximum power point tracking control strategy for variable-speed wind turbine generation system

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Whei-Min; Hong, Chih-Ming [Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung 80424 (China)

    2010-06-15

    To achieve maximum power point tracking (MPPT) for wind power generation systems, the rotational speed of wind turbines should be adjusted in real time according to wind speed. In this paper, a Wilcoxon radial basis function network (WRBFN) with hill-climb searching (HCS) MPPT strategy is proposed for a permanent magnet synchronous generator (PMSG) with a variable-speed wind turbine. A high-performance online training WRBFN using a back-propagation learning algorithm with modified particle swarm optimization (MPSO) regulating controller is designed for a PMSG. The MPSO is adopted in this study to adapt to the learning rates in the back-propagation process of the WRBFN to improve the learning capability. The MPPT strategy locates the system operation points along the maximum power curves based on the dc-link voltage of the inverter, thus avoiding the generator speed detection. (author)

  15. Dynamic performance of maximum power point tracking circuits using sinusoidal extremum seeking control for photovoltaic generation

    Science.gov (United States)

    Leyva, R.; Artillan, P.; Cabal, C.; Estibals, B.; Alonso, C.

    2011-04-01

    The article studies the dynamic performance of a family of maximum power point tracking circuits used for photovoltaic generation. It revisits the sinusoidal extremum seeking control (ESC) technique which can be considered as a particular subgroup of the Perturb and Observe algorithms. The sinusoidal ESC technique consists of adding a small sinusoidal disturbance to the input and processing the perturbed output to drive the operating point at its maximum. The output processing involves a synchronous multiplication and a filtering stage. The filter instance determines the dynamic performance of the MPPT based on sinusoidal ESC principle. The approach uses the well-known root-locus method to give insight about damping degree and settlement time of maximum-seeking waveforms. This article shows the transient waveforms in three different filter instances to illustrate the approach. Finally, an experimental prototype corroborates the dynamic analysis.

  16. Status of hospital infection control measures at seven major tertiary care hospitals of northern Punjab

    International Nuclear Information System (INIS)

    Ikram, A.; Shah, S.I.H.; Naseem, S.; Absar, S.A.; Safi-Ullah; Ambreen, T.

    2010-01-01

    To determine the availability and implementation of various hospital infection control measures at tertiary care hospitals. Study Design: Survey. Place and Duration of Study: National Institute of Science and Technology, Islamabad, from June through August 2008. Methodology: Seven tertiary care very busy hospitals were selected; one from Islamabad, 5 from Rawalpindi, and one from Lahore. A detailed proforma was designed addressing all the issues pertaining to hospital infection control measures. Air sampling was done and growth yielded was identified by standard methods. Results: Analyses revealed that all of the hospitals had an Infection Control Committee. Microbiological diagnostic facilities were adequate at all the hospitals and overall microorganism yield was very high. Antibiotic policy was claimed by most, not available on ground. Majority of the operation theatres were without proper air flow system and autoclaves were not being regularly monitored. There was no proper disposal for sharps and needles. Incineration was not the usual mode for infectious waste. Conclusion: The results of the present study imply availability of proper hospital infection control policies with need of strict implementation of such measures. (author)

  17. DIRECT GEOREFERENCING ON SMALL UNMANNED AERIAL PLATFORMS FOR IMPROVED RELIABILITY AND ACCURACY OF MAPPING WITHOUT THE NEED FOR GROUND CONTROL POINTS

    Directory of Open Access Journals (Sweden)

    O. Mian

    2015-08-01

    Full Text Available This paper presents results from a Direct Mapping Solution (DMS comprised of an Applanix APX-15 UAV GNSS-Inertial system integrated with a Sony a7R camera to produce highly accurate ortho-rectified imagery without Ground Control Points on a Microdrones md4-1000 platform. A 55 millimeter Nikkor f/1.8 lens was mounted on the Sony a7R and the camera was then focused and calibrated terrestrially using the Applanix camera calibration facility, and then integrated with the APX-15 UAV GNSS-Inertial system using a custom mount specifically designed for UAV applications. In July 2015, Applanix and Avyon carried out a test flight of this system. The goal of the test flight was to assess the performance of DMS APX-15 UAV direct georeferencing system on the md4-1000. The area mapped during the test was a 250 x 300 meter block in a rural setting in Ontario, Canada. Several ground control points are distributed within the test area. The test included 8 North-South lines and 1 cross strip flown at 80 meters AGL, resulting in a ~1 centimeter Ground Sample Distance (GSD. Map products were generated from the test flight using Direct Georeferencing, and then compared for accuracy against the known positions of ground control points in the test area. The GNSS-Inertial data collected by the APX-15 UAV was post-processed in Single Base mode, using a base station located in the project area via POSPac UAV. The base-station’s position was precisely determined by processing a 12-hour session using the CSRS-PPP Post Processing service. The ground control points were surveyed in using differential GNSS post-processing techniques with respect to the base-station.

  18. Geodetic Control Points - National Geodetic Survey Benchmarks

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — This data contains a set of geodetic control stations maintained by the National Geodetic Survey. Each geodetic control station in this dataset has either a precise...

  19. Management Control in Major Brazilian Multiple Banks: the Impact of Internationalization and Convergence of Accounting Standards on the Control Systems

    Directory of Open Access Journals (Sweden)

    João Carlos Damasceno Reis

    2014-08-01

    Full Text Available This study verifies the impact caused by the processes of globalization and convergence to international accounting standards on the managerial control systems of the largest multiple banks that operate in Brazil. The study was exploratory in nature, with the use of the case study method and the application of questionnaires containing mostly open questions to upper tier executives of four major Brazilian banks. The analysis showed that globalization has resulted in improved control systems and widespread use of information technology. It was also found that the convergence to international accounting standards occurred properly, thanks to the steps taken by the Central Bank that aimed at an agile updating of the Brazilian accounting standards laid down for banks operating in Brazil, in line with international standards. In general, the researched banks did not report a significant impact of convergence to the IFRS on their management control systems; adherence to the international accounting standards has had more significant impacts on information systems, especially regarding the new reporting and transparency standards, rather than on management controls. This result signals that the management control systems of the four banks in the sample are in line with Anthony (1965’s vision, that is, that flexibility to adapt to every change in the external environment might actually increase risks of failure.

  20. Usefulness of K-Point Injection for the Nonspecific Neck Pain in So-Called K-Point Syndrome.

    Science.gov (United States)

    Moon, Jeong Jae; Ahn, Myun Whan; Ahn, Hyo Sae; Lee, Sung Jun; Lee, Dong Yeol

    2016-12-01

    Shoichi Kokubun introduced his successful experience with local anesthetic injection at the occipital insertion of the sternocleidomastoid muscle in K-point syndrome. The purpose of this study was to evaluate the short-term and long-term effectiveness of K-point injection and investigate factors affecting treatment results. K-point injection was performed in 58 patients with K-point syndrome at Yeungnam University Medical Center. The syndrome was associated with cervical whiplash injury in 10 patients and was of nonspecific origin in the rest. One milliliter of 2% lidocaine mixed with 1 milliliter of dexamethasone was injected in 50 patients and 2 milliliters of 1% lidocaine alone in the rest. Initially, the severity of local tenderness at the K-point and other tender points was examined and the degree of immediate pain relief effect was assessed within 1 hour after injection. Early effect within 1 month after the injection and current effect were evaluated in 27 patients using a modified Kim's questionnaire with regard to the duration of improvement, degree of improvement in pain and daily living activities, and satisfaction. Of the total 58 patients, 44 (75.8%) apparently had immediate pain relief after K-point injection. The only factor associated with successful immediate pain relief was the whiplash injury associated with traffic accident (TA). The early pain control effect was associated with the immediate effect. The current effect was associated with the early effect alone. Satisfaction with the K-point injection was related to early successful pain relief. K-point injection would be useful for early pain relief in nonspecific neck pain syndrome so called K-point syndrome, but not for current pain relief. Especially, it was very effective for early pain control in the whiplash injury associated with TA.

  1. Critical Point Facility (CPE) Group in the Spacelab Payload Operations Control Center (SL POCC)

    Science.gov (United States)

    1992-01-01

    The primary payload for Space Shuttle Mission STS-42, launched January 22, 1992, was the International Microgravity Laboratory-1 (IML-1), a pressurized manned Spacelab module. The goal of IML-1 was to explore in depth the complex effects of weightlessness of living organisms and materials processing. Around-the-clock research was performed on the human nervous system's adaptation to low gravity and effects of microgravity on other life forms such as shrimp eggs, lentil seedlings, fruit fly eggs, and bacteria. Materials processing experiments were also conducted, including crystal growth from a variety of substances such as enzymes, mercury iodide, and a virus. The Huntsville Operations Support Center (HOSC) Spacelab Payload Operations Control Center (SL POCC) at the Marshall Space Flight Center (MSFC) was the air/ground communication channel used between the astronauts and ground control teams during the Spacelab missions. Featured is the Critical Point Facility (CPE) group in the SL POCC during STS-42, IML-1 mission.

  2. Point of sale tobacco advertisements in India.

    Science.gov (United States)

    Chaudhry, S; Chaudhry, S; Chaudhry, K

    2007-01-01

    The effect of any legislation depends on its implementation. Limited studies indicate that tobacco companies may tend to use such provision for surrogate advertising. The point of sale advertisement provision has been placed in the Indian Tobacco Control legislation. The study was undertaken to assess the Indian scenario in this regard. To assess if there are any violations related to provision of point of tobacco sale advertisements under India's comprehensive tobacco Control legislation in different parts of India. Boards over various shops showing advertisements of tobacco products were observed in the cities of Delhi, Mumbai, Kolkata, Trivandrum and Jaipur, between September 2005 and March 2006. The point of sale advertisements mushroomed after the implementation of 2004 tobacco control legislation. Tobacco advertisement boards fully satisfying the point of sale provision were practically non-existent. The most common violation of point of sale advertisements was the larger size of the board but with tobacco advertisement equal to the size indicated in the legislation and remaining area often showing a picture. Invariably two boards were placed together to provide the impression of a large single repetitive advertisement. More than two boards was not common. Tobacco advertisement boards were also observed on closed shops/ warehouses, shops not selling tobacco products and on several adjacent shops. The purpose of the point of sale advertisements seems to be surrogate advertisement of tobacco products, mainly cigarettes.

  3. One of the Major Problems in Tuberculosis Control: Adherence to Therapy

    Directory of Open Access Journals (Sweden)

    Belguzar Kara

    2009-02-01

    Full Text Available Abstract: Although tuberculosis (TB is a preventable and curable disease, approximately one third of the world’s population is infected with the TB bacillus. Tuberculosis is a major public health problem in especially developing countries. Nonadherence to TB therapy regimes is common, as treatment is difficult and requires long courses of multiple antibiotics. It is estimated that the rate of nonadherence to TB treatment ranges from 20 to 80%. Nonadherence to TB treatment is the most serious barrier in disease control because incomplete treatment may result in prolonged infectiousness, drug resistance, relapse and death. However, handling the factors affecting adherence to treatment for the patients may increase the efficiency of the treatment and help to reach better health outcomes. This article reviews evidence regarding adherence to TB treatment in patients and affecting factors and makes recommendations for health care professionals. [TAF Prev Med Bull 2009; 8(1.000: 75-82

  4. Personality styles in patients with fibromyalgia, major depression and healthy controls

    Directory of Open Access Journals (Sweden)

    Stiles Tore C

    2007-03-01

    Full Text Available Abstract Background The fibromyalgia syndrome (FMS is suggested to be a manifestation of depression or affective spectrum disorder. We measured the cognitive style of patients with FMS to assess personality styles in 44 patients with fibromyalgia syndrome (FMS by comparing them with 43 patients with major depressive disorder (MDD and 41 healthy controls (HC. Methods Personality styles were measured by the Sociotropy and Autonomy Scale (SAS and the Dysfunctional Attitude Scale (DAS. The Structured Clinical interview for DSM Axis I was applied to Axis I disorders, while the Beck Depression Inventory was used to measure depression severity. Results Patients with FMS in general have a sociotropic personality style similar to patients with MDD, and different from HC, but FMS patients without a lifetime history of MDD had a cognitive personality style different from patients with MDD and similar to HC. Conclusion These findings suggest that a depressotypic personality style is related to depressive disorder, but not to FMS.

  5. Analysis of hygienic critical control points in boar semen production.

    Science.gov (United States)

    Schulze, M; Ammon, C; Rüdiger, K; Jung, M; Grobbel, M

    2015-02-01

    The present study addresses the microbiological results of a quality control audit in artificial insemination (AI) boar studs in Germany and Austria. The raw and processed semen of 344 boars in 24 AI boar studs were analyzed. Bacteria were found in 26% (88 of 344) of the extended ejaculates and 66.7% (18 of 24) of the boar studs. The bacterial species found in the AI dose were not cultured from the respective raw semen in 95.5% (84 of 88) of the positive samples. These data, together with the fact that in most cases all the samples from one stud were contaminated with identical bacteria (species and resistance profile), indicate contamination during processing. Microbiological investigations of the equipment and the laboratory environment during semen processing in 21 AI boar studs revealed nine hygienic critical control points (HCCP), which were addressed after the first audit. On the basis of the analysis of the contamination rates of the ejaculate samples, improvements in the hygiene status were already present in the second audit (P = 0.0343, F-test). Significant differences were observed for heating cabinets (improvement, P = 0.0388) and manual operating elements (improvement, P = 0.0002). The odds ratio of finding contaminated ejaculates in the first and second audit was 1.68 (with the 95% confidence interval ranging from 1.04 to 2.69). Furthermore, an overall good hygienic status was shown for extenders, the inner face of dilution tank lids, dyes, and ultrapure water treatment plants. Among the nine HCCP considered, the most heavily contaminated samples, as assessed by the median scores throughout all the studs, were found in the sinks and/or drains. High numbers (>10(3) colony-forming units/cm(2)) of bacteria were found in the heating cabinets, ejaculate transfer, manual operating elements, and laboratory surfaces. In conclusion, the present study emphasizes the need for both training of the laboratory staff in monitoring HCCP in routine semen

  6. The Potential of Established Fitness Cut-off Points for Monitoring Women with Fibromyalgia: The al-Ándalus Project.

    Science.gov (United States)

    Castro-Piñero, José; Aparicio, Virginia A; Estévez-López, Fernando; Álvarez-Gallardo, Inmaculada C; Borges-Cosic, Milkana; Soriano-Maldonado, Alberto; Delgado-Fernández, Manuel; Segura-Jiménez, Víctor

    2017-05-01

    The aim of the present study was to determinate whether fitness cut-off points discriminate the severity of major fibromyalgia symptoms and health-related quality of life. Additionally, we investigated which American Colleague of Rheumatology (ACR) fibromyalgia criteria (1990 vs. modified 2010) better discriminate fibromyalgia symptomatology. A total of 488 women with fibromyalgia and 200 non-fibromyalgia (control) women participated. All participants underwent both the 1990 and the modified 2010 ACR preliminary criteria (hereinafter 1990c and m-2010c, respectively). We used fitness cut-off points (Senior Fitness Tests Battery plus handgrip strength test) to discriminate between presence and absence of fibromyalgia. Additionally, we employed several instruments to assess fibromyalgia symptoms. Fitness cut-off points discriminated between high and low levels of the main symptoms the disease in all age groups (P from fibromyalgia diagnosis and monitoring. Moreover, the effect size of the differences in symptoms between women with fibromyalgia and controls were overall larger using the m-2010c compared with the 1990c, except for the tender points count, reflecting better the polysymptomatic distress condition of fibromyalgia. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Perfectionism moderates stereotype threat effects on STEM majors' academic performance.

    Science.gov (United States)

    Rice, Kenneth G; Lopez, Frederick G; Richardson, Clarissa M E; Stinson, Jennifer M

    2013-04-01

    Using a randomized, between-subjects experimental design, we tested hypotheses that self-critical perfectionism would moderate the effects of subtle stereotype threat (ST) for women and students in underrepresented racial/ethnic groups who are pursuing traditional degrees in science, technology, engineering, or math (STEM). A diverse sample of freshmen students (N = 294) was recruited from 2 major universities. Students were blocked by gender and race/ethnicity and randomly assigned to experience subtle ST or no ST. Participants in the subtle ST condition were primed to consider their gender, race, and ethnicity prior to completing measures of science self-efficacy. Those in the control condition completed the measures without such priming. Controlling for prior academic performance and university context, ST priming significantly interacted (a) with self-critical perfectionism to predict coping self-efficacy scores and (b) with race/ethnicity to predict end-of-semester STEM grades. A 3-way interaction of ST priming, sex, and self-critical perfectionism also predicted students' grades in courses wherein women and men were more proportionally represented. The Sex × Self-Critical Perfectionism interaction was not significant for those in the ST group but was for those in the control group. Men in the control group had higher grade-point averages (GPAs) at low levels of self-critical perfectionism than they had at higher levels of perfectionism. In contrast, women had lower GPAs when self-critical perfectionism was low, but their GPAs were higher when self-critical perfectionism was high. The findings are discussed in terms of their implications for self-efficacy and performance in the pursuit of a STEM major.

  8. The Effects of Group Play Therapy on Self-Concept Among 7 to 11 Year-Old Children Suffering From Thalassemia Major.

    Science.gov (United States)

    Tomaj, Ome Kolsoum; Estebsari, Fatemeh; Taghavi, Taraneh; Borim Nejad, Leili; Dastoorpoor, Maryam; Ghasemi, Afsaneh

    2016-04-01

    Children suffering from thalassemia have higher levels of depression and lower levels of self-concept. The aim of this study was to determine if group play therapy could significantly increase self-concept among children with thalassemia major ages 7 to 11 years old in teaching hospitals of Golestan province, Iran, in 2012. In this randomized, controlled clinical trial, 60 children with thalassemia major were randomly assigned to intervention (30 children) and control (30 children) groups. The intervention included eight 45 to 60 minute sessions during four weeks, during which the intervention group received group play therapy. The control group received no interventions. Self-concept was measured three times using the Piers-Harris children's self-concept scale: before, immediately after, and a month after the intervention. For the intervention group, results showed that the mean self-concept score was significantly higher at the second point in time compared to the baseline (P 0.05). The results showed that group play therapy improves self-concept in children suffering from thalassemia major.

  9. Identification of gram-negative bacteria from critical control points of raw and pasteurized cow milk consumed at Gondar town and its suburbs, Ethiopia.

    Science.gov (United States)

    Garedew, Legesse; Berhanu, Ayalew; Mengesha, Desalegne; Tsegay, Getachew

    2012-11-06

    Milk is highly prone to contamination and can serve as an efficient vehicle for human transmission of foodborne pathogens, especially gram-negative bacteria, as these are widely distributed in the environment. This cross-sectional study of gram-negative staining bacterial contamination of milk meant for human consumption was carried out from October 2010 to May 2011 in Gondar town, Ethiopia. Milk samples were collected from critical control points, from production to consumption, that were hypothesized to be a source of potential contamination. Milk sampling points included smallholder's milk producers, dairy co-operatives, a milk processing plant, and supermarkets. The hygienic procedures applied during milking, milk collection, transportation, pasteurization, and postpasteurization storage conditions at these specified critical control points were evaluated. Standard bacteriological cultivation and biochemical assays were used to isolate and identify bacterial pathogens in the milk samples. The results of the current study showed that conditions for contamination of raw milk at different critical points were due to less hygienic practices in pre-milking udder preparation, sub-optimal hygiene of milk handlers, and poor sanitation practices associated with milking and storage equipments. Among all critical control points considered, transportation containers at milk collection centers and at processing plants were found to be the most heavily contaminated with gram-negative staining bacterial species. Overall, 54 different bacterial species were indentified, and Escherichia coli (29.6%), Pseudomonas aeruginosa (18.5%), and Klebsiella pneumoniae (16.7%), were the most commonly identified gram-negative staining bacterial pathogens. Of particular interest was that no gram-negative staining bacteria were isolated from pasteurized milk samples with varying shelf life. This study showed the presence of diverse pathogenic gram-negative staining bacterial species in raw

  10. Identification of gram-negative bacteria from critical control points of raw and pasteurized cow milk consumed at Gondar town and its suburbs, Ethiopia

    Directory of Open Access Journals (Sweden)

    Garedew Legesse

    2012-11-01

    Full Text Available Abstract Background Milk is highly prone to contamination and can serve as an efficient vehicle for human transmission of foodborne pathogens, especially gram-negative bacteria, as these are widely distributed in the environment. Methods This cross-sectional study of gram-negative staining bacterial contamination of milk meant for human consumption was carried out from October 2010 to May 2011 in Gondar town, Ethiopia. Milk samples were collected from critical control points, from production to consumption, that were hypothesized to be a source of potential contamination. Milk sampling points included smallholder’s milk producers, dairy co-operatives, a milk processing plant, and supermarkets. The hygienic procedures applied during milking, milk collection, transportation, pasteurization, and postpasteurization storage conditions at these specified critical control points were evaluated. Standard bacteriological cultivation and biochemical assays were used to isolate and identify bacterial pathogens in the milk samples. Results The results of the current study showed that conditions for contamination of raw milk at different critical points were due to less hygienic practices in pre-milking udder preparation, sub-optimal hygiene of milk handlers, and poor sanitation practices associated with milking and storage equipments. Among all critical control points considered, transportation containers at milk collection centers and at processing plants were found to be the most heavily contaminated with gram-negative staining bacterial species. Overall, 54 different bacterial species were indentified, and Escherichia coli (29.6%, Pseudomonas aeruginosa (18.5%, and Klebsiella pneumoniae (16.7%, were the most commonly identified gram-negative staining bacterial pathogens. Of particular interest was that no gram-negative staining bacteria were isolated from pasteurized milk samples with varying shelf life. Conclusion This study showed the presence of

  11. A Homogeneous and Self-Dual Interior-Point Linear Programming Algorithm for Economic Model Predictive Control

    DEFF Research Database (Denmark)

    Sokoler, Leo Emil; Frison, Gianluca; Skajaa, Anders

    2015-01-01

    We develop an efficient homogeneous and self-dual interior-point method (IPM) for the linear programs arising in economic model predictive control of constrained linear systems with linear objective functions. The algorithm is based on a Riccati iteration procedure, which is adapted to the linear...... system of equations solved in homogeneous and self-dual IPMs. Fast convergence is further achieved using a warm-start strategy. We implement the algorithm in MATLAB and C. Its performance is tested using a conceptual power management case study. Closed loop simulations show that 1) the proposed algorithm...

  12. Flight mission control for multiple spacecraft

    Science.gov (United States)

    Ryan, Robert E.

    1990-10-01

    A plan developed by the Jet Propulsion Laboratory for mission control of unmanned spacecraft is outlined. A technical matrix organization from which, in the past, project teams were formed to uniquely support a mission is replaced in this new plan. A cost effective approach was needed to make best use of limited resources. Mission control is a focal point operations and a good place to start a multimission concept. Co-location and sharing common functions are the keys to obtaining efficiencies at minimum additional risk. For the projects, the major changes are sharing a common operations area and having indirect control of personnel. The plan identifies the still direct link for the mission control functions. Training is a major element in this plan. Personnel are qualified for a position and certified for a mission. This concept is more easily accepted by new missions than the ongoing missions.

  13. [Incorporation of the Hazard Analysis and Critical Control Point system (HACCP) in food legislation].

    Science.gov (United States)

    Castellanos Rey, Liliana C; Villamil Jiménez, Luis C; Romero Prada, Jaime R

    2004-01-01

    The Hazard Analysis and Critical Control Point system (HACCP), recommended by different international organizations as the Codex Alimentarius Commission, the World Trade Organization (WTO), the International Office of Epizootics (OIE) and the International Convention for Vegetables Protection (ICPV) amongst others, contributes to ensuring the innocuity of food along the agro-alimentary chain and requires of Good Manufacturing Practices (GMP) for its implementation, GMP's which are legislated in most countries. Since 1997, Colombia has set rules and legislation for application of HACCP system in agreement with international standards. This paper discusses the potential and difficulties of the legislation enforcement and suggests some policy implications towards food safety.

  14. Synthetic organic agrochemicals in the lower Mississippi River and its major tributaries--Distribution, transport and fate

    Science.gov (United States)

    Pereira, W.E.; Rostad, C.E.; Leiker, T.J.

    1992-01-01

    The Mississippi River and its major tributaries transport herbicides and their degradation products from agricultural areas in the mid-western U.S.A. These compounds include atrazine and its degradation products (desethyl- and desisopropylatrazine), simazine, cyanazine, metolachlor, and alachlor and its degradation products (2-chloro-2′,6′-diethylacetanilide 2-hydroxy-2′,6′-diethylacetanilide and 2,6-diethylaniline). These compounds were identified and confirmed by gas chromatography-ion trap mass spectrometry. Loads of these compounds were determined during five sampling trips in 1987–1989. Stream loads of these compounds indicated that atrazine and metolachlor were relatively conservative in downstream transport. Alachlor and its degradation products were generated from point and non-point sources. Seasonal variations and hydrologic conditions controlled the loads of these compounds in the Mississippi River. Cross-channel mixing was slow downstream from major river confluences, possibly requiring several hundred kilometers of downriver transit for completion. The annual transport of these compounds into the Gulf of Mexico was estimated to be < 2% of the annual application of each herbicide in the Midwest.

  15. Food safety and nutritional quality for the prevention of non communicable diseases: the Nutrient, hazard Analysis and Critical Control Point process (NACCP).

    Science.gov (United States)

    Di Renzo, Laura; Colica, Carmen; Carraro, Alberto; Cenci Goga, Beniamino; Marsella, Luigi Tonino; Botta, Roberto; Colombo, Maria Laura; Gratteri, Santo; Chang, Ting Fa Margherita; Droli, Maurizio; Sarlo, Francesca; De Lorenzo, Antonino

    2015-04-23

    The important role of food and nutrition in public health is being increasingly recognized as crucial for its potential impact on health-related quality of life and the economy, both at the societal and individual levels. The prevalence of non-communicable diseases calls for a reformulation of our view of food. The Hazard Analysis and Critical Control Point (HACCP) system, first implemented in the EU with the Directive 43/93/CEE, later replaced by Regulation CE 178/2002 and Regulation CE 852/2004, is the internationally agreed approach for food safety control. Our aim is to develop a new procedure for the assessment of the Nutrient, hazard Analysis and Critical Control Point (NACCP) process, for total quality management (TMQ), and optimize nutritional levels. NACCP was based on four general principles: i) guarantee of health maintenance; ii) evaluate and assure the nutritional quality of food and TMQ; iii) give correct information to the consumers; iv) ensure an ethical profit. There are three stages for the application of the NACCP process: 1) application of NACCP for quality principles; 2) application of NACCP for health principals; 3) implementation of the NACCP process. The actions are: 1) identification of nutritional markers, which must remain intact throughout the food supply chain; 2) identification of critical control points which must monitored in order to minimize the likelihood of a reduction in quality; 3) establishment of critical limits to maintain adequate levels of nutrient; 4) establishment, and implementation of effective monitoring procedures of critical control points; 5) establishment of corrective actions; 6) identification of metabolic biomarkers; 7) evaluation of the effects of food intake, through the application of specific clinical trials; 8) establishment of procedures for consumer information; 9) implementation of the Health claim Regulation EU 1924/2006; 10) starting a training program. We calculate the risk assessment as follows

  16. An Improvement of a Fuzzy Logic-Controlled Maximum Power Point Tracking Algorithm for Photovoltic Applications

    Directory of Open Access Journals (Sweden)

    Woonki Na

    2017-03-01

    Full Text Available This paper presents an improved maximum power point tracking (MPPT algorithm using a fuzzy logic controller (FLC in order to extract potential maximum power from photovoltaic cells. The objectives of the proposed algorithm are to improve the tracking speed, and to simultaneously solve the inherent drawbacks such as slow tracking in the conventional perturb and observe (P and O algorithm. The performances of the conventional P and O algorithm and the proposed algorithm are compared by using MATLAB/Simulink in terms of the tracking speed and steady-state oscillations. Additionally, both algorithms were experimentally validated through a digital signal processor (DSP-based controlled-boost DC-DC converter. The experimental results show that the proposed algorithm performs with a shorter tracking time, smaller output power oscillation, and higher efficiency, compared with the conventional P and O algorithm.

  17. Time Series UAV Image-Based Point Clouds for Landslide Progression Evaluation Applications.

    Science.gov (United States)

    Al-Rawabdeh, Abdulla; Moussa, Adel; Foroutan, Marzieh; El-Sheimy, Naser; Habib, Ayman

    2017-10-18

    Landslides are major and constantly changing threats to urban landscapes and infrastructure. It is essential to detect and capture landslide changes regularly. Traditional methods for monitoring landslides are time-consuming, costly, dangerous, and the quality and quantity of the data is sometimes unable to meet the necessary requirements of geotechnical projects. This motivates the development of more automatic and efficient remote sensing approaches for landslide progression evaluation. Automatic change detection involving low-altitude unmanned aerial vehicle image-based point clouds, although proven, is relatively unexplored, and little research has been done in terms of accounting for volumetric changes. In this study, a methodology for automatically deriving change displacement rates, in a horizontal direction based on comparisons between extracted landslide scarps from multiple time periods, has been developed. Compared with the iterative closest projected point (ICPP) registration method, the developed method takes full advantage of automated geometric measuring, leading to fast processing. The proposed approach easily processes a large number of images from different epochs and enables the creation of registered image-based point clouds without the use of extensive ground control point information or further processing such as interpretation and image correlation. The produced results are promising for use in the field of landslide research.

  18. Tracking the maximum efficiency point for the FC system based on extremum seeking scheme to control the air flow

    International Nuclear Information System (INIS)

    Bizon, Nicu

    2014-01-01

    Highlights: • The Maximum Efficiency Point (MEP) is tracked based on air flow rate. • The proposed Extremum Seeking (ES) control assures high performances. • About 10 kW/s search speed and 99.99% stationary accuracy can be obtained. • The energy efficiency increases with 3–12%, according to the power losses. • The control strategy is robust based on self-optimizing ES scheme proposed. - Abstract: An advanced control of the air compressor for the Proton Exchange Membrane Fuel Cell (PEMFC) system is proposed in this paper based on Extremum Seeking (ES) control scheme. The FC net power is mainly depended on the air and hydrogen flow rate and pressure, and heat and water management. This paper proposes to compute the optimal value for the air flow rate based on the advanced ES control scheme in order to maximize the FC net power. In this way, the Maximum Efficiency Point (MEP) will be tracked in real time, with about 10 kW/s search speed and a stationary accuracy of 0.99. Thus, energy efficiency will be close to the maximum value that can be obtained for a given PEMFC stack and compressor group under dynamic load. It is shown that the MEP tracking allows an increasing of the FC net power with 3–12%, depending on the percentage of the FC power supplied to the compressor and the level of the load power. Simulations shows that the performances mentioned above are effective

  19. Maximum power point tracking

    International Nuclear Information System (INIS)

    Enslin, J.H.R.

    1990-01-01

    A well engineered renewable remote energy system, utilizing the principal of Maximum Power Point Tracking can be m ore cost effective, has a higher reliability and can improve the quality of life in remote areas. This paper reports that a high-efficient power electronic converter, for converting the output voltage of a solar panel, or wind generator, to the required DC battery bus voltage has been realized. The converter is controlled to track the maximum power point of the input source under varying input and output parameters. Maximum power point tracking for relative small systems is achieved by maximization of the output current in a battery charging regulator, using an optimized hill-climbing, inexpensive microprocessor based algorithm. Through practical field measurements it is shown that a minimum input source saving of 15% on 3-5 kWh/day systems can easily be achieved. A total cost saving of at least 10-15% on the capital cost of these systems are achievable for relative small rating Remote Area Power Supply systems. The advantages at larger temperature variations and larger power rated systems are much higher. Other advantages include optimal sizing and system monitor and control

  20. The effects of practice on movement distance and final position reproduction: implications for the equilibrium-point control of movements.

    Science.gov (United States)

    Jaric, S; Corcos, D M; Gottlieb, G L; Ilic, D B; Latash, M L

    1994-01-01

    Predictions of two views on single-joint motor control, namely programming of muscle force patterns and equilibrium-point control, were compared with the results of experiments with reproduction of movement distance and final location during fast unidirectional elbow flexions. Two groups of subjects were tested. The first group practiced movements over a fixed distance (36 degrees), starting from seven different initial positions (distance group, DG). The second group practiced movements from the same seven initial positions to a fixed final location (location group, LG). Later, all the subjects were tested at the practiced task with their eyes closed, and then, unexpectedly for the subjects, they were tested at the other, unpracticed task. In both groups, the task to reproduce final position had lower indices of final position variability than the task to reproduce movement distance. Analysis of the linear regression lines between initial position and final position (or movement distance) also demonstrated a better (more accurate) performance during final position reproduction than during distance reproduction. The data are in a good correspondence with the predictions of the equilibrium-point hypothesis, but not with the predictions of the force-pattern control approach.

  1. Automatic Optimization of Focal Point Position in CO2 Laser Welding with Neural Network in A Focus Control System

    DEFF Research Database (Denmark)

    Gong, Hui; Olsen, Flemming Ove

    CO2 lasers are increasingly being utilized for quality welding in production. Considering the high cost of equipment, the start-up time and the set-up time should be minimized. Ideally the parameters should be set up and optimized more or less automatically. In this paper a control system...... is designed and built to automatically optimize the focal point position, one of the most important parameters in CO2 laser welding, in order to perform a desired deep/full penetration welding. The control system mainly consists of a multi-axis motion controller - PMAC, a light sensor - Photo Diode, a data...

  2. Control over structure-specific flexibility improves anatomical accuracy for point-based deformable registration in bladder cancer radiotherapy.

    Science.gov (United States)

    Wognum, S; Bondar, L; Zolnay, A G; Chai, X; Hulshof, M C C M; Hoogeman, M S; Bel, A

    2013-02-01

    Future developments in image guided adaptive radiotherapy (IGART) for bladder cancer require accurate deformable image registration techniques for the precise assessment of tumor and bladder motion and deformation that occur as a result of large bladder volume changes during the course of radiotherapy treatment. The aim was to employ an extended version of a point-based deformable registration algorithm that allows control over tissue-specific flexibility in combination with the authors' unique patient dataset, in order to overcome two major challenges of bladder cancer registration, i.e., the difficulty in accounting for the difference in flexibility between the bladder wall and tumor and the lack of visible anatomical landmarks for validation. The registration algorithm used in the current study is an extension of the symmetric-thin plate splines-robust point matching (S-TPS-RPM) algorithm, a symmetric feature-based registration method. The S-TPS-RPM algorithm has been previously extended to allow control over the degree of flexibility of different structures via a weight parameter. The extended weighted S-TPS-RPM algorithm was tested and validated on CT data (planning- and four to five repeat-CTs) of five urinary bladder cancer patients who received lipiodol injections before radiotherapy. The performance of the weighted S-TPS-RPM method, applied to bladder and tumor structures simultaneously, was compared with a previous version of the S-TPS-RPM algorithm applied to bladder wall structure alone and with a simultaneous nonweighted S-TPS-RPM registration of the bladder and tumor structures. Performance was assessed in terms of anatomical and geometric accuracy. The anatomical accuracy was calculated as the residual distance error (RDE) of the lipiodol markers and the geometric accuracy was determined by the surface distance, surface coverage, and inverse consistency errors. Optimal parameter values for the flexibility and bladder weight parameters were determined

  3. Control over structure-specific flexibility improves anatomical accuracy for point-based deformable registration in bladder cancer radiotherapy

    International Nuclear Information System (INIS)

    Wognum, S.; Chai, X.; Hulshof, M. C. C. M.; Bel, A.; Bondar, L.; Zolnay, A. G.; Hoogeman, M. S.

    2013-01-01

    Purpose: Future developments in image guided adaptive radiotherapy (IGART) for bladder cancer require accurate deformable image registration techniques for the precise assessment of tumor and bladder motion and deformation that occur as a result of large bladder volume changes during the course of radiotherapy treatment. The aim was to employ an extended version of a point-based deformable registration algorithm that allows control over tissue-specific flexibility in combination with the authors’ unique patient dataset, in order to overcome two major challenges of bladder cancer registration, i.e., the difficulty in accounting for the difference in flexibility between the bladder wall and tumor and the lack of visible anatomical landmarks for validation. Methods: The registration algorithm used in the current study is an extension of the symmetric-thin plate splines-robust point matching (S-TPS-RPM) algorithm, a symmetric feature-based registration method. The S-TPS-RPM algorithm has been previously extended to allow control over the degree of flexibility of different structures via a weight parameter. The extended weighted S-TPS-RPM algorithm was tested and validated on CT data (planning- and four to five repeat-CTs) of five urinary bladder cancer patients who received lipiodol injections before radiotherapy. The performance of the weighted S-TPS-RPM method, applied to bladder and tumor structures simultaneously, was compared with a previous version of the S-TPS-RPM algorithm applied to bladder wall structure alone and with a simultaneous nonweighted S-TPS-RPM registration of the bladder and tumor structures. Performance was assessed in terms of anatomical and geometric accuracy. The anatomical accuracy was calculated as the residual distance error (RDE) of the lipiodol markers and the geometric accuracy was determined by the surface distance, surface coverage, and inverse consistency errors. Optimal parameter values for the flexibility and bladder weight

  4. Control over structure-specific flexibility improves anatomical accuracy for point-based deformable registration in bladder cancer radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Wognum, S.; Chai, X.; Hulshof, M. C. C. M.; Bel, A. [Department of Radiotherapy, Academic Medical Center, Meiberdreef 9, 1105 AZ Amsterdam (Netherlands); Bondar, L.; Zolnay, A. G.; Hoogeman, M. S. [Department of Radiation Oncology, Daniel den Hoed Cancer Center, Erasmus Medical Center, Groene Hilledijk 301, 3075 EA Rotterdam (Netherlands)

    2013-02-15

    Purpose: Future developments in image guided adaptive radiotherapy (IGART) for bladder cancer require accurate deformable image registration techniques for the precise assessment of tumor and bladder motion and deformation that occur as a result of large bladder volume changes during the course of radiotherapy treatment. The aim was to employ an extended version of a point-based deformable registration algorithm that allows control over tissue-specific flexibility in combination with the authors' unique patient dataset, in order to overcome two major challenges of bladder cancer registration, i.e., the difficulty in accounting for the difference in flexibility between the bladder wall and tumor and the lack of visible anatomical landmarks for validation. Methods: The registration algorithm used in the current study is an extension of the symmetric-thin plate splines-robust point matching (S-TPS-RPM) algorithm, a symmetric feature-based registration method. The S-TPS-RPM algorithm has been previously extended to allow control over the degree of flexibility of different structures via a weight parameter. The extended weighted S-TPS-RPM algorithm was tested and validated on CT data (planning- and four to five repeat-CTs) of five urinary bladder cancer patients who received lipiodol injections before radiotherapy. The performance of the weighted S-TPS-RPM method, applied to bladder and tumor structures simultaneously, was compared with a previous version of the S-TPS-RPM algorithm applied to bladder wall structure alone and with a simultaneous nonweighted S-TPS-RPM registration of the bladder and tumor structures. Performance was assessed in terms of anatomical and geometric accuracy. The anatomical accuracy was calculated as the residual distance error (RDE) of the lipiodol markers and the geometric accuracy was determined by the surface distance, surface coverage, and inverse consistency errors. Optimal parameter values for the flexibility and bladder weight

  5. Design and Integration of an All-Magnetic Attitude Control System for FASTSAT-HSV01's Multiple Pointing Objectives

    Science.gov (United States)

    DeKock, Brandon; Sanders, Devon; Vanzwieten, Tannen; Capo-Lugo, Pedro

    2011-01-01

    The FASTSAT-HSV01 spacecraft is a microsatellite with magnetic torque rods as it sole attitude control actuator. FASTSAT s multiple payloads and mission functions require the Attitude Control System (ACS) to maintain Local Vertical Local Horizontal (LVLH)-referenced attitudes without spin-stabilization, while the pointing errors for some attitudes be significantly smaller than the previous best-demonstrated for this type of control system. The mission requires the ACS to hold multiple stable, unstable, and non-equilibrium attitudes, as well as eject a 3U CubeSat from an onboard P-POD and recover from the ensuing tumble. This paper describes the Attitude Control System, the reasons for design choices, how the ACS integrates with the rest of the spacecraft, and gives recommendations for potential future applications of the work.

  6. Point-by-point written fiber-Bragg gratings and their application in complex grating designs.

    Science.gov (United States)

    Marshall, Graham D; Williams, Robert J; Jovanovic, Nemanja; Steel, M J; Withford, Michael J

    2010-09-13

    The point-by-point technique of fabricating fibre-Bragg gratings using an ultrafast laser enables complete control of the position of each index modification that comprises the grating. By tailoring the local phase, amplitude and spacing of the grating's refractive index modulations it is possible to create gratings with complex transmission and reflection spectra. We report a series of grating structures that were realized by exploiting these flexibilities. Such structures include gratings with controlled bandwidth, and amplitude- and phase-modulated sampled (or superstructured) gratings. A model based on coupled-mode theory provides important insights into the manufacture of such gratings. Our approach offers a quick and easy method of producing complex, non-uniform grating structures in both fibres and other mono-mode waveguiding structures.

  7. Insular and Hippocampal Gray Matter Volume Reductions in Patients with Major Depressive Disorder

    Science.gov (United States)

    Kugel, Harald; Krug, Axel; Schöning, Sonja; Ohrmann, Patricia; Uhlmann, Christina; Postert, Christian; Suslow, Thomas; Heindel, Walter; Arolt, Volker; Kircher, Tilo; Dannlowski, Udo

    2014-01-01

    Background Major depressive disorder is a serious psychiatric illness with a highly variable and heterogeneous clinical course. Due to the lack of consistent data from previous studies, the study of morphometric changes in major depressive disorder is still a major point of research requiring additional studies. The aim of the study presented here was to characterize and quantify regional gray matter abnormalities in a large sample of clinically well-characterized patients with major depressive disorder. Methods For this study one-hundred thirty two patients with major depressive disorder and 132 age- and gender-matched healthy control participants were included, 35 with their first episode and 97 with recurrent depression. To analyse gray matter abnormalities, voxel-based morphometry (VBM8) was employed on T1 weighted MRI data. We performed whole-brain analyses as well as a region-of-interest approach on the hippocampal formation, anterior cingulate cortex and amygdala, correlating the number of depressive episodes. Results Compared to healthy control persons, patients showed a strong gray-matter reduction in the right anterior insula. In addition, region-of-interest analyses revealed significant gray-matter reductions in the hippocampal formation. The observed alterations were more severe in patients with recurrent depressive episodes than in patients with a first episode. The number of depressive episodes was negatively correlated with gray-matter volume in the right hippocampus and right amygdala. Conclusions The anterior insula gray matter structure appears to be strongly affected in major depressive disorder and might play an important role in the neurobiology of depression. The hippocampal and amygdala volume loss cumulating with the number of episodes might be explained either by repeated neurotoxic stress or alternatively by higher relapse rates in patients showing hippocampal atrophy. PMID:25051163

  8. The resilience of an operating point for a fusion power plant

    Energy Technology Data Exchange (ETDEWEB)

    Ward, David, E-mail: david.ward@ccfe.ac.uk; Kemp, Richard

    2015-10-15

    Highlights: • The need to control a power plant changes our view of the optimum design. • The need for control can be reduced by finding resilient design points. • It is important to include resilience and control in selecting design points. • Including these additional constraints reduces flexibility in choice of operating points. - Abstract: The operating point for fusion power plant design concepts is often determined by simultaneously satisfying the requirements of all of the main plant systems and finding an optimum solution, for instance the one with the lowest capital cost or cost of electricity. This static assessment takes no account of the sensitivity of that operating point to variations in key parameters and therefore includes no information about how difficult to adjust and control the chosen operating point may be. Control of the operation point is a large subject with much work still to be done, and is expected to play an increasing role in the future in choosing the optimum design point. Here we present results of two analyses: one relates to the ability to load follow, that is, to vary the power production in the light of varying demands for power from the electricity network; the other investigates in simple terms what choices we can make to improve the resilience of static operating points.

  9. Fixed point theory in metric type spaces

    CERN Document Server

    Agarwal, Ravi P; O’Regan, Donal; Roldán-López-de-Hierro, Antonio Francisco

    2015-01-01

    Written by a team of leading experts in the field, this volume presents a self-contained account of the theory, techniques and results in metric type spaces (in particular in G-metric spaces); that is, the text approaches this important area of fixed point analysis beginning from the basic ideas of metric space topology. The text is structured so that it leads the reader from preliminaries and historical notes on metric spaces (in particular G-metric spaces) and on mappings, to Banach type contraction theorems in metric type spaces, fixed point theory in partially ordered G-metric spaces, fixed point theory for expansive mappings in metric type spaces, generalizations, present results and techniques in a very general abstract setting and framework. Fixed point theory is one of the major research areas in nonlinear analysis. This is partly due to the fact that in many real world problems fixed point theory is the basic mathematical tool used to establish the existence of solutions to problems which arise natur...

  10. A major QTL controls susceptibility to spinal curvature in the curveback guppy

    Directory of Open Access Journals (Sweden)

    Dreyer Christine

    2011-01-01

    Full Text Available Abstract Background Understanding the genetic basis of heritable spinal curvature would benefit medicine and aquaculture. Heritable spinal curvature among otherwise healthy children (i.e. Idiopathic Scoliosis and Scheuermann kyphosis accounts for more than 80% of all spinal curvatures and imposes a substantial healthcare cost through bracing, hospitalizations, surgery, and chronic back pain. In aquaculture, the prevalence of heritable spinal curvature can reach as high as 80% of a stock, and thus imposes a substantial cost through production losses. The genetic basis of heritable spinal curvature is unknown and so the objective of this work is to identify quantitative trait loci (QTL affecting heritable spinal curvature in the curveback guppy. Prior work with curveback has demonstrated phenotypic parallels to human idiopathic-type scoliosis, suggesting shared biological pathways for the deformity. Results A major effect QTL that acts in a recessive manner and accounts for curve susceptibility was detected in an initial mapping cross on LG 14. In a second cross, we confirmed this susceptibility locus and fine mapped it to a 5 cM region that explains 82.6% of the total phenotypic variance. Conclusions We identify a major QTL that controls susceptibility to curvature. This locus contains over 100 genes, including MTNR1B, a candidate gene for human idiopathic scoliosis. The identification of genes associated with heritable spinal curvature in the curveback guppy has the potential to elucidate the biological basis of spinal curvature among humans and economically important teleosts.

  11. Economic consequences of major accidents in the industrial plants: The case of a nuclear power plant

    International Nuclear Information System (INIS)

    Fraix, J.

    1989-09-01

    These last years, newspapers head-lines have reported various accidents (Mexico City, Bhopal, Chernobyl, ...) which have drawn attention to the fact that the major technological risk is now a reality and that, undoubtedly, industrial decision-makers ought to integrate it into their preoccupations. In addition to the sometimes considerable human problems such accidents engender, their economic consequences may be such that they become significant on a national or even international scale. The aim of the present paper is to analyse these economic effects by using the particular context of a nuclear power plant. The author has deliberately limited his subject to the consequences of a major accident, that is to say a sudden event, theoretically unforeseen and beyond man's control. The qualification major means an accident of which the consequences extend far beyond the industrial plant itself. The direct and indirect economic consequences are analysed from the responsibility point of view as well as from the national and international community's point of view. A paragraph explains how the coverage of the costs can rely on the cooperation of a number of parties: responsible company, state, insurers, customers, etc. The study is broadly based on the experience resulting from the two major accidents which happened in the nuclear industry these last years (Three Mile Island in 1979 and Chernobyl in 1986) and makes use of more theoretical considerations, for example in the field of the economic evaluation of human life. (author). 58 refs, 2 figs, 12 tabs

  12. Case management and quality: have we reached a tipping point?

    Science.gov (United States)

    Dulworth, Sherrie

    2006-01-01

    In The Tipping Point, Malcolm Gladwell describes a phenomenon in which a niche market or fad undergoes transformation into mainstream acceptability, resulting in widespread social change. He concludes that a "tipping point" occurs when a series of small events results in a critical mass of acceptance that produces sudden major changes.

  13. Distortion product otoacoustic emissions in college music majors and nonmusic majors

    Directory of Open Access Journals (Sweden)

    Rebecca L. Warner Henning

    2016-01-01

    Full Text Available The presence and absence of distortion product otoacoustic emissions (DPOAEs as well as DPOAE amplitudes were compared between college music majors and a control group of nonmusic majors. Participants included 28 music majors and 35 nonmusic majors enrolled at a university with ages ranging from 18-25 years. DPOAEs and hearing thresholds were measured bilaterally on all the participants. DPOAE amplitudes were analyzed at the following f2 frequencies: 1,187 Hz, 1,500 Hz, 1,906 Hz, 2,531 Hz, 3,031 Hz, 3812 Hz, 4,812 Hz, and 6,031 Hz. Significantly more music majors (7/28 than nonmusic majors (0/35 exhibited absent DPOAEs for at least one frequency in at least one ear. Both groups of students reported similar histories of recreational and occupational noise exposures that were unrelated to studying music, and none of the students reported high levels of noise exposure within the previous 48 h. There were no differences in audiometric thresholds between the groups at any frequency. At DPOAE f2 frequencies from 3,031 Hz to 6,031 Hz, nonsignificantly lower amplitudes of 2-4 dB were seen in the right ears of music majors versus nonmajors, and in the right ears of music majors playing brass instruments compared to music majors playing nonbrass instruments. Given the greater prevalence of absent DPOAEs in university music majors compared to nonmusic majors, it appears that early stages of cochlear damage may be occurring in this population. Additional research, preferably longitudinal and across multiple colleges/universities, would be beneficial to more definitively determine when the music students begin to show signs of cochlear damage, and to identify whether any particular subgroups of music majors are at a greater risk of cochlear damage.

  14. Hardware description ADSP-21020 40-bit floating point DSP as designed in a remotely controlled digital CW Doppler radar

    Science.gov (United States)

    Morrison, R. E.; Robinson, S. H.

    A continuous wave Doppler radar system has been designed which is portable, easily deployed, and remotely controlled. The heart of this system is a DSP/control board using Analog Devices ADSP-21020 40-bit floating point digital signal processor (DSP) microprocessor. Two 18-bit audio A/D converters provide digital input to the DSP/controller board for near real time target detection. Program memory for the DSP is dual ported with an Intel 87C51 microcontroller allowing DSP code to be up-loaded or down-loaded from a central controlling computer. The 87C51 provides overall system control for the remote radar and includes a time-of-day/day-of-year real time clock, system identification (ID) switches, and input/output (I/O) expansion by an Intel 82C55 I/O expander.

  15. Efficiency of stormwater control measures for combined sewer retrofitting under varying rain conditions: Quantifying the Three Points Approach (3PA)

    DEFF Research Database (Denmark)

    Sørup, Hjalte Jomo Danielsen; Lerer, Sara Maria; Arnbjerg-Nielsen, Karsten

    2016-01-01

    We present a method to assess and communicate the efficiency of stormwater control measures for retrofitting existing urban areas. The tool extends the Three Points Approach to quantitatively distinguish three rainfall domains: (A) rainwater resource utilisation, (B) urban stormwater drainage pip...

  16. Immediate Effect of Needling at CV-12 (Zhongwan) Acupuncture Point on Blood Glucose Level in Patients with Type 2 Diabetes Mellitus: A Pilot Randomized Placebo-Controlled Trial.

    Science.gov (United States)

    Kumar, Ranjan; Mooventhan, A; Manjunath, Nandi Krishnamurthy

    2017-08-01

    Diabetes mellitus is a major global health problem. Needling at CV-12 has reduced blood glucose level in diabetic rats. The aim of this study was to evaluate the effect of needling at CV-12 (Zhongwan) on blood glucose level in patients with type 2 diabetes mellitus (T2DM). Forty T2DM patients were recruited and randomized into either the acupuncture group or placebo control group. The participants in the acupuncture group were needled at CV-12 (4 cun above the center of the umbilicus), and those in the placebo control group were needled at a placebo point on the right side of the abdomen (1 cun beside the CV-12). For both groups, the needle was retained for 30 minutes. Assessments were performed prior to and after the intervention. Statistical analysis was performed using SPSS version 16. There was a significant reduction in random blood glucose level in the acupuncture group compared to baseline. No such significant change was observed in the placebo control group. The result of this study suggests that 30 minutes of needling at CV-12 might be useful in reducing blood glucose level in patients with T2DM. Copyright © 2017. Published by Elsevier B.V.

  17. Track and mode controller (TMC): a software executive for a high-altitude pointing and tracking experiment

    Science.gov (United States)

    Michnovicz, Michael R.

    1997-06-01

    A real-time executive has been implemented to control a high altitude pointing and tracking experiment. The track and mode controller (TMC) implements a table driven design, in which the track mode logic for a tracking mission is defined within a state transition diagram (STD). THe STD is implemented as a state transition table in the TMC software. Status Events trigger the state transitions in the STD. Each state, as it is entered, causes a number of processes to be activated within the system. As these processes propagate through the system, the status of key processes are monitored by the TMC, allowing further transitions within the STD. This architecture is implemented in real-time, using the vxWorks operating system. VxWorks message queues allow communication of status events from the Event Monitor task to the STD task. Process commands are propagated to the rest of the system processors by means of the SCRAMNet shared memory network. The system mode logic contained in the STD will autonomously sequence in acquisition, tracking and pointing system through an entire engagement sequence, starting with target detection and ending with aimpoint maintenance. Simulation results and lab test results will be presented to verify the mode controller. In addition to implementing the system mode logic with the STD, the TMC can process prerecorded time sequences of commands required during startup operations. It can also process single commands from the system operator. In this paper, the author presents (1) an overview, in which he describes the TMC architecture, the relationship of an end-to-end simulation to the flight software and the laboratory testing environment, (2) implementation details, including information on the vxWorks message queues and the SCRAMNet shared memory network, (3) simulation results and lab test results which verify the mode controller, and (4) plans for the future, specifically as to how this executive will expedite transition to a fully

  18. Metallogenetic characteristics of major fault in area No.212-318

    International Nuclear Information System (INIS)

    Zhang Yong

    1994-01-01

    Based on the distribution characteristics of major fault on the plan and assemblage form of major and subsidiary faults on the section, this paper expounds the relationship between major fault and uranium ore-formation, namely: different orders of fault structure control the spatial distribution of ore fields, ore deposits and ore bodies respectively, regional turning sites of the major fault control the ore fields; local turning sites of the major fault control ore deposits; different types of structural assemblages control ore bodies. Whether the matter compositions of fault structure are simple or not, it plays an absolutely important role in ore-formation. The complicated matter compositions of fault structures are favourable for ore-formation, conversely, simple compositions are unfavourable

  19. Policy on Hazard Analysis and Critical Control Point (HACCP) and adherence to food preparation guidelines: a cross sectional survey of stakeholders in food service in Kumasi, Ghana.

    Science.gov (United States)

    Agyei-Baffour, Peter; Sekyere, Kofi Boateng; Addy, Ernestine Akosua

    2013-11-04

    Food borne diseases claim more lives and are growing public health concerns. Simple preventive techniques such as adoption and adherence to hazard analysis and critical control point (HACCP) policy can significantly reduce this disease burden. Though food screening and inspection are done, the ultimate regulation, Hazard Analysis and Critical Control Point, which is known and accepted worldwide, appears not to be popular among food operators in Ghana. This paper examines the level of awareness of the existence of policy on hazard analysis and critical control point (HACCP) and its adherence to food preparation guidelines among food service providers in Ghana. The results revealed the mean age of food providers as 33.1 years with a standard deviation of 7.5, range of 18-55 years, more females, in full time employment and with basic education. Of the fifty institutional managers, 42 (84%) were senior officers and had worked for more than five years. Education and type of food operator had strong statistically significant relationship with the implementation of HCCP policy and adherence with food preparation guidelines. The enforcement of HACCP policy and adherence with food safety guidelines was led by the Ghana Tourist Board, Public Health officers, and KMA, respectively. While a majority of food operators 373/450 (83.3%) did not know HACCP policy is part of food safety guidelines, staff of food safety law enforcement 44/50 (88%) confirmed knowing that food operators were not aware of the HACCP policy. The study documents evidence on the practice of food safety principles or HACCP policy or adherence to food preparation guidelines. Existing food safety guidelines incorporate varying principles of HACCP, however, awareness is low among food operators. The implication is that food production is likely to fall short of acceptable standards and not be wholesome putting consumers at health risk. Repeating this study in rural and urban areas in Ghana is necessary to

  20. Dew point vs bubble point : a misunderstood constraint on gravity drainage processes

    Energy Technology Data Exchange (ETDEWEB)

    Nenninger, J. [N-Solv Corp., Calgary, AB (Canada); Gunnewiek, L. [Hatch Ltd., Mississauga, ON (Canada)

    2009-07-01

    This study demonstrated that gravity drainage processes that use blended fluids such as solvents have an inherently unstable material balance due to differences between dew point and bubble point compositions. The instability can lead to the accumulation of volatile components within the chamber, and impair mass and heat transfer processes. Case studies were used to demonstrate the large temperature gradients within the vapour chamber caused by temperature differences between the bubble point and dew point for blended fluids. A review of published data showed that many experiments on in-situ processes do not account for unstable material balances caused by a lack of steam trap control. A study of temperature profiles during steam assisted gravity drainage (SAGD) studies showed significant temperature depressions caused by methane accumulations at the outside perimeter of the steam chamber. It was demonstrated that the condensation of large volumes of purified solvents provided an efficient mechanism for the removal of methane from the chamber. It was concluded that gravity drainage processes can be optimized by using pure propane during the injection process. 22 refs., 1 tab., 18 figs.

  1. A major gene controls mimicry and crypsis in butterflies and moths

    Science.gov (United States)

    Nadeau, Nicola J.; Pardo-Diaz, Carolina; Whibley, Annabel; Supple, Megan; Saenko, Suzanne V.; Wallbank, Richard W. R.; Wu, Grace C.; Maroja, Luana; Ferguson, Laura; Hanly, Joseph J.; Hines, Heather; Salazar, Camilo; Merrill, Richard; Dowling, Andrea; ffrench-Constant, Richard; Llaurens, Violaine; Joron, Mathieu; McMillan, W. Owen; Jiggins, Chris D.

    2016-01-01

    The wing patterns of butterflies and moths (Lepidoptera) are diverse and striking examples of evolutionary diversification by natural selection1,2. Lepidopteran wing colour patterns are a key innovation, consisting of arrays of coloured scales. We still lack a general understanding of how these patterns are controlled and if there is any commonality across the 160,000 moth and 17,000 butterfly species. Here, we identify a gene, cortex, through fine-scale mapping using population genomics and gene expression analyses, which regulates pattern switches in multiple species across the mimetic radiation in Heliconius butterflies. cortex belongs to a fast evolving subfamily of the otherwise highly conserved fizzy family of cell cycle regulators3, suggesting that it most likely regulates pigmentation patterning through regulation of scale cell development. In parallel with findings in the peppered moth (Biston betularia)4, our results suggest that this mechanism is common within Lepidoptera and that cortex has become a major target for natural selection acting on colour and pattern variation in this group of insects. PMID:27251285

  2. Ground Control Point - Wireless System Network for UAV-based environmental monitoring applications

    Science.gov (United States)

    Mejia-Aguilar, Abraham

    2016-04-01

    In recent years, Unmanned Aerial Vehicles (UAV) have seen widespread civil applications including usage for survey and monitoring services in areas such as agriculture, construction and civil engineering, private surveillance and reconnaissance services and cultural heritage management. Most aerial monitoring services require the integration of information acquired during the flight (such as imagery) with ground-based information (such as GPS information or others) for improved ground truth validation. For example, to obtain an accurate 3D and Digital Elevation Model based on aerial imagery, it is necessary to include ground-based information of coordinate points, which are normally acquired with surveying methods based on Global Position Systems (GPS). However, GPS surveys are very time consuming and especially for longer time series of monitoring data repeated GPS surveys are necessary. In order to improve speed of data collection and integration, this work presents an autonomous system based on Waspmote technologies build on single nodes interlinked in a Wireless Sensor Network (WSN) star-topology for ground based information collection and later integration with surveying data obtained by UAV. Nodes are designed to be visible from the air, to resist extreme weather conditions with low-power consumption. Besides, nodes are equipped with GPS as well as Inertial Measurement Unit (IMU), accelerometer, temperature and soil moisture sensors and thus provide significant advantages in a broad range of applications for environmental monitoring. For our purpose, the WSN transmits the environmental data with 3G/GPRS to a database on a regular time basis. This project provides a detailed case study and implementation of a Ground Control Point System Network for UAV-based vegetation monitoring of dry mountain grassland in the Matsch valley, Italy.

  3. Thoracic epidural analgesia reduces myocardial injury in ischemic patients undergoing major abdominal cancer surgery

    Directory of Open Access Journals (Sweden)

    Mohamad MF

    2017-04-01

    to PCIA at all measured time points. Regarding perioperative hemodynamics, there was a significant reduction in intra-operative mean arterial pressure (MAP; and heart rate in PCEA group in comparison to PCIA group at most of measured time points while there was not a significant reduction in postoperative MAP and heart rate in the second and third post-operative days. The incidence of other postoperative complications such as DVT, pneumonia and in hospital mortality were decreased in PCEA group.Conclusion: Perioperative thoracic epidural analgesia in patients suffering from coronary artery disease subjected to major abdominal cancer surgery reduced significantly postoperative major adverse cardiac events with better pain control in comparison with perioperative IV analgesia. Keywords: postoperative myocardial infarction, thoracic epidural analgesia, PCA

  4. AN ADAPTIVE APPROACH FOR SEGMENTATION OF 3D LASER POINT CLOUD

    Directory of Open Access Journals (Sweden)

    Z. Lari

    2012-09-01

    Full Text Available Automatic processing and object extraction from 3D laser point cloud is one of the major research topics in the field of photogrammetry. Segmentation is an essential step in the processing of laser point cloud, and the quality of extracted objects from laser data is highly dependent on the validity of the segmentation results. This paper presents a new approach for reliable and efficient segmentation of planar patches from a 3D laser point cloud. In this method, the neighbourhood of each point is firstly established using an adaptive cylinder while considering the local point density and surface trend. This neighbourhood definition has a major effect on the computational accuracy of the segmentation attributes. In order to efficiently cluster planar surfaces and prevent introducing ambiguities, the coordinates of the origin's projection on each point's best fitted plane are used as the clustering attributes. Then, an octree space partitioning method is utilized to detect and extract peaks from the attribute space. Each detected peak represents a specific cluster of points which are located on a distinct planar surface in the object space. Experimental results show the potential and feasibility of applying this method for segmentation of both airborne and terrestrial laser data.

  5. Generalized transmissibilities for corner point rids in reservoir simulation; Transmissibilidades generalizadas em malhas corner point na simulacao de reservatorios

    Energy Technology Data Exchange (ETDEWEB)

    Tada, Mauricio P.; Silva, Antonio Fabio C. da; Maliska, Clovis R. [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil). Lab. de Simulacao Numerica em Mecanica dos Fluidos e Transferencia de Calor (SINMEC)

    2008-07-01

    It is common to use five points schemes in reservoir simulation, since it simplifies the computational implementation and takes the linear resultant system simplest to be solved, giving more process velocity and robust to simulator. However, the use of these schemes may introduce significant errors solutions as function of volume's non orthogonality and medium anisotropy. These errors do not disappear with grid refinement since they are not truncate errors, it is a flux calculus approximation in the control volume faces. In order to get a correct solution and with no errors of these kind, it must be used a nine point scheme based on the correct flux calculus. The objective of this work is to present a new methodology to calculate the transmissibility on simulation reservoir that use a five and nine points scheme with corner-points grids. This mode considers full tensor anisotropy and the heterogeneity. The transmissibility presented are derivative of the discrete flux expression through control volume faces, where a generalized curvilinear coordinate system, located inner to the control volume, it is adopted. The transmissibility is then written on vector form and may to be used for any coordinate system. (author)

  6. Maximum power point tracker based on fuzzy logic

    International Nuclear Information System (INIS)

    Daoud, A.; Midoun, A.

    2006-01-01

    The solar energy is used as power source in photovoltaic power systems and the need for an intelligent power management system is important to obtain the maximum power from the limited solar panels. With the changing of the sun illumination due to variation of angle of incidence of sun radiation and of the temperature of the panels, Maximum Power Point Tracker (MPPT) enables optimization of solar power generation. The MPPT is a sub-system designed to extract the maximum power from a power source. In the case of solar panels power source. the maximum power point varies as a result of changes in its electrical characteristics which in turn are functions of radiation dose, temperature, ageing and other effects. The MPPT maximum the power output from panels for a given set of conditions by detecting the best working point of the power characteristic and then controls the current through the panels or the voltage across them. Many MPPT methods have been reported in literature. These techniques of MPPT can be classified into three main categories that include: lookup table methods, hill climbing methods and computational methods. The techniques vary according to the degree of sophistication, processing time and memory requirements. The perturbation and observation algorithm (hill climbing technique) is commonly used due to its ease of implementation, and relative tracking efficiency. However, it has been shown that when the insolation changes rapidly, the perturbation and observation method is slow to track the maximum power point. In recent years, the fuzzy controllers are used for maximum power point tracking. This method only requires the linguistic control rules for maximum power point, the mathematical model is not required and therefore the implementation of this control method is easy to real control system. In this paper, we we present a simple robust MPPT using fuzzy set theory where the hardware consists of the microchip's microcontroller unit control card and

  7. Optimal Control Of Nonlinear Wave Energy Point Converters

    DEFF Research Database (Denmark)

    Nielsen, Søren R.K.; Zhou, Qiang; Kramer, Morten

    2013-01-01

    idea behind the control strategy is to enforce the stationary velocity response of the absorber into phase with the wave excitation force at any time. The controller is optimal under monochromatic wave excitation. It is demonstrated that the devised causal controller, in plane irregular sea states...

  8. Tuning of PID controller using optimization techniques for a MIMO process

    Science.gov (United States)

    Thulasi dharan, S.; Kavyarasan, K.; Bagyaveereswaran, V.

    2017-11-01

    In this paper, two processes were considered one is Quadruple tank process and the other is CSTR (Continuous Stirred Tank Reactor) process. These are majorly used in many industrial applications for various domains, especially, CSTR in chemical plants.At first mathematical model of both the process is to be done followed by linearization of the system due to MIMO process and controllers are the major part to control the whole process to our desired point as per the applications so the tuning of the controller plays a major role among the whole process. For tuning of parameters we use two optimizations techniques like Particle Swarm Optimization, Genetic Algorithm. The above techniques are majorly used in different applications to obtain which gives the best among all, we use these techniques to obtain the best tuned values among many. Finally, we will compare the performance of the each process with both the techniques.

  9. A randomized controlled trial of single point acupuncture in primary dysmenorrhea.

    Science.gov (United States)

    Liu, Cun-Zhi; Xie, Jie-Ping; Wang, Lin-Peng; Liu, Yu-Qi; Song, Jia-Shan; Chen, Yin-Ying; Shi, Guang-Xia; Zhou, Wei; Gao, Shu-Zhong; Li, Shi-Liang; Xing, Jian-Min; Ma, Liang-Xiao; Wang, Yan-Xia; Zhu, Jiang; Liu, Jian-Ping

    2014-06-01

    Acupuncture is often used for primary dysmenorrhea. But there is no convincing evidence due to low methodological quality. We aim to assess immediate effect of acupuncture at specific acupoint compared with unrelated acupoint and nonacupoint on primary dysmenorrhea. The Acupuncture Analgesia Effect in Primary Dysmenorrhoea-II is a multicenter controlled trial conducted in six large hospitals of China. Patients who met inclusion criteria were randomly assigned to classic acupoint (N = 167), unrelated acupoint (N = 167), or non-acupoint (N = 167) group on a 1:1:1 basis. They received three sessions with electro-acupuncture at a classic acupoint (Sanyinjiao, SP6), or an unrelated acupoint (Xuanzhong, GB39), or nonacupoint location, respectively. The primary outcome was subjective pain as measured by a 100-mm visual analog scale (VAS). Measurements were obtained at 0, 5, 10, 30, and 60 minutes following the first intervention. In addition, patients scored changes of general complaints using Cox retrospective symptom scales (RSS-Cox) and 7-point verbal rating scale (VRS) during three menstrual cycles. Secondary outcomes included VAS score for average pain, pain total time, additional in-bed time, and proportion of participants using analgesics during three menstrual cycles. Five hundred and one people underwent random assignment. The primary comparison of VAS scores following the first intervention demonstrated that classic acupoint group was more effective both than unrelated acupoint (-4.0 mm, 95% CI -7.1 to -0.9, P = 0.010) and nonacupoint (-4.0 mm, 95% CI -7.0 to -0.9, P = 0.012) groups. However, no significant differences were detected among the three acupuncture groups for RSS-Cox or VRS outcomes. The per-protocol analysis showed similar pattern. No serious adverse events were noted. Specific acupoint acupuncture produced a statistically, but not clinically, significant effect compared with unrelated acupoint and nonacupoint acupuncture in

  10. Retailer opinions about and compliance with family smoking prevention and tobacco control act point of sale provisions: a survey of tobacco retailers.

    Science.gov (United States)

    Rose, Shyanika W; Emery, Sherry L; Ennett, Susan; Reyes, Heathe Luz McNaughton; Scott, John C; Ribisl, Kurt M

    2015-09-11

    The objectives of this study were to document retailer opinions about tobacco control policy at the point of sale (POS) and link these opinions with store level compliance with sales and marketing provisions of the Tobacco Control Act. This study conducted interviews of 252 tobacco retailers in three counties in North Carolina and linked their opinions with in-person observational audit data of their stores' compliance with POS policies. We conducted analyses examining retailer factors associated with noncompliance using Generalized Estimating Equations (GEE) controlling for individual, store, neighborhood, and county factors. Over 90 % of retailers support minors' access provisions and a large minority (over 40 %) support graphic warnings and promotion bans. Low levels of support were found for a potential ban on menthol cigarettes (17 %). Store noncompliance with tobacco control policies was associated with both more reported retailer barriers to compliance and less support for POS policies. Awareness of and source of information about tobacco control regulations were not associated with compliance when accounting for neighborhood and county characteristics. Retailers expressed some support for a wide range of POS policies. Advocates and government agencies tasked with enforcement can work with retailers as stakeholders to enhance support, mitigate barriers, and promote compliance with tobacco control efforts at the point of sale.

  11. Investigation on the pinch point position in heat exchangers

    Science.gov (United States)

    Pan, Lisheng; Shi, Weixiu

    2016-06-01

    The pinch point is important for analyzing heat transfer in thermodynamic cycles. With the aim to reveal the importance of determining the accurate pinch point, the research on the pinch point position is carried out by theoretical method. The results show that the pinch point position depends on the parameters of the heat transfer fluids and the major fluid properties. In most cases, the pinch point locates at the bubble point for the evaporator and the dew point for the condenser. However, the pinch point shifts to the supercooled liquid state in the near critical conditions for the evaporator. Similarly, it shifts to the superheated vapor state with the condensing temperature approaching the critical temperature for the condenser. It even can shift to the working fluid entrance of the evaporator or the supercritical heater when the heat source fluid temperature is very high compared with the absorbing heat temperature. A wrong position for the pinch point may generate serious mistake. In brief, the pinch point should be founded by the iterative method in all conditions rather than taking for granted.

  12. Experimental Tracking of Limit-Point Bifurcations and Backbone Curves Using Control-Based Continuation

    Science.gov (United States)

    Renson, Ludovic; Barton, David A. W.; Neild, Simon A.

    Control-based continuation (CBC) is a means of applying numerical continuation directly to a physical experiment for bifurcation analysis without the use of a mathematical model. CBC enables the detection and tracking of bifurcations directly, without the need for a post-processing stage as is often the case for more traditional experimental approaches. In this paper, we use CBC to directly locate limit-point bifurcations of a periodically forced oscillator and track them as forcing parameters are varied. Backbone curves, which capture the overall frequency-amplitude dependence of the system’s forced response, are also traced out directly. The proposed method is demonstrated on a single-degree-of-freedom mechanical system with a nonlinear stiffness characteristic. Results are presented for two configurations of the nonlinearity — one where it exhibits a hardening stiffness characteristic and one where it exhibits softening-hardening.

  13. [Management of intractable epistaxis and bleeding points localization].

    Science.gov (United States)

    Yang, Da-Zhang; Cheng, Jing-Ning; Han, Jun; Shu, Ping; Zhang, Hua

    2005-05-01

    To investigate the common nasal bleeding points and the management of intractable epistaxis. The bleeding points and its correlation with age distribution, surgical techniques as well as its effects were studied retrospectively in 92 patients, in whom the bleeding points were not found by routine nasal endoscopy and the hemorrhage was not controlled with standard nasal packing. The bleeding points were found in the following different sites: superior wall of inferior nasal meatus (56.5%, 52/92), olfactory cleft of nasal septum (27.2%, 25/92), posterosuperior wall of middle nasal meatus (8.7%, 8/92) and uncertain (7.6%, 7/92). The results showed that the bleeding points had correlation with age. Epistaxis was well controlled by electrocoagulation in 83 cases, gelfoam packing in 8 cases, and transcatheter maxillary artery embolization in 1 case. There were no complications during a followed-up for 1 - 3 months after management. Among the 92 cases, the numbers of treatment needed to stop bleeding were 82 cases (89.1%) after 1 time of treatment, 9 cases (9.8%) after 2 times and in one case (1.1%) after 4 times. Endoscopy combined with displacement of the middle and inferior turbinate gives good visualization and direct management of the deeply-sited bleeding points, which were difficult in localization. The combined method provides an effective and safe way to control intractable epistaxis.

  14. Photovoltaic System with Smart Tracking of the Optimal Working Point

    Directory of Open Access Journals (Sweden)

    PATARAU, T.

    2010-08-01

    Full Text Available A photovoltaic (PV system, based on a Maximum Power Point Tracking (MPPT controller that extracts the maximum possible output power from the solar panel is described. Output efficiency of a PV energy system can be achieved only if the system working point is brought near the maximum power point (MPP. The proposed system, making use of several MPPT control algorithms (Perturb and Observe, Incremental conductance, Fuzzy Logic, demonstrates in simulations as well as in real experiments good tracking of the optimal working point.

  15. Five-axis Control Processing Using NC Machine Tools : A Tool Posture Decision Using the Tangent Slope at a Cut Point on a Work

    OpenAIRE

    小島, 龍広; 西田, 知照; 扇谷, 保彦

    2003-01-01

    This report deals with the way to decide tool posture and the way to analytically calculate tool path for the work shape requiring 5-axis control machining. In the tool path calculation, basic equations are derived using the principle that the tangent slope at a cut point on a work and the one at a cutting point on a tool edge are identical. A tool posture decision procedure using the tangent slope at each cut point on a work is proposed for any shape of tool edge. The valid- ity of the way t...

  16. Process Control/SCADA system vendor security awareness and security posture.

    NARCIS (Netherlands)

    Luiijf, H.A.M.; Lüders, S.

    2009-01-01

    A starting point for the adequate security of process control/SCADA systems is the security awareness and security posture by the manufacturers, vendors, system integrators, and service organisations. The results of a short set of questions indicate that major security improvements are required in

  17. Barriers to Point-of-Care Testing in India: Results from Qualitative Research across Different Settings, Users and Major Diseases

    Science.gov (United States)

    Engel, Nora; Ganesh, Gayatri; Patil, Mamata; Yellappa, Vijayashree; Pant Pai, Nitika; Vadnais, Caroline; Pai, Madhukar

    2015-01-01

    Background Successful point-of-care testing, namely ensuring the completion of the test and treat cycle in the same encounter, has immense potential to reduce diagnostic and treatment delays, and impact patient outcomes. However, having rapid tests is not enough, as many barriers may prevent their successful implementation in point-of-care testing programs. Qualitative research on diagnostic practices may help identify such barriers across different points of care in health systems. Methods In this exploratory qualitative study, we conducted 78 semi-structured interviews and 13 focus group discussions in an urban and rural area of Karnataka, India, with healthcare providers (doctors, nurses, specialists, traditional healers, and informal providers), patients, community health workers, test manufacturers, laboratory technicians, program managers and policy-makers. Participants were purposively sampled to represent settings of hospitals, peripheral labs, clinics, communities and homes, in both the public and private sectors. Results In the Indian context, the onus is on the patient to ensure successful point-of-care testing across homes, clinics, labs and hospitals, amidst uncoordinated providers with divergent and often competing practices, in settings lacking material, money and human resources. We identified three overarching themes affecting point-of-care testing: the main theme is ‘relationships’ among providers and between providers and patients, influenced by the cross-cutting theme of ‘infrastructure’. Challenges with both result in ‘modified practices’ often favouring empirical (symptomatic) treatment over treatment guided by testing. Conclusions Even if tests can be conducted on the spot and infrastructure challenges have been resolved, relationships among providers and between patients and providers are crucial for successful point-of-care testing. Furthermore, these barriers do not act in isolation, but are interlinked and need to be examined

  18. Barriers to Point-of-Care Testing in India: Results from Qualitative Research across Different Settings, Users and Major Diseases.

    Directory of Open Access Journals (Sweden)

    Nora Engel

    Full Text Available Successful point-of-care testing, namely ensuring the completion of the test and treat cycle in the same encounter, has immense potential to reduce diagnostic and treatment delays, and impact patient outcomes. However, having rapid tests is not enough, as many barriers may prevent their successful implementation in point-of-care testing programs. Qualitative research on diagnostic practices may help identify such barriers across different points of care in health systems.In this exploratory qualitative study, we conducted 78 semi-structured interviews and 13 focus group discussions in an urban and rural area of Karnataka, India, with healthcare providers (doctors, nurses, specialists, traditional healers, and informal providers, patients, community health workers, test manufacturers, laboratory technicians, program managers and policy-makers. Participants were purposively sampled to represent settings of hospitals, peripheral labs, clinics, communities and homes, in both the public and private sectors.In the Indian context, the onus is on the patient to ensure successful point-of-care testing across homes, clinics, labs and hospitals, amidst uncoordinated providers with divergent and often competing practices, in settings lacking material, money and human resources. We identified three overarching themes affecting point-of-care testing: the main theme is 'relationships' among providers and between providers and patients, influenced by the cross-cutting theme of 'infrastructure'. Challenges with both result in 'modified practices' often favouring empirical (symptomatic treatment over treatment guided by testing.Even if tests can be conducted on the spot and infrastructure challenges have been resolved, relationships among providers and between patients and providers are crucial for successful point-of-care testing. Furthermore, these barriers do not act in isolation, but are interlinked and need to be examined as such. Also, a test alone has only

  19. Allogeneic major histocompatibility complex-mismatched equine bone marrow-derived mesenchymal stem cells are targeted for death by cytotoxic anti-major histocompatibility complex antibodies.

    Science.gov (United States)

    Berglund, A K; Schnabel, L V

    2017-07-01

    Allogeneic mesenchymal stem cells (MSCs) are a promising cell source for treating musculoskeletal injuries in horses. Controversy exists, however, over whether major histocompatibility complex (MHC)-mismatched MSCs are recognised by the recipient immune system and targeted for death by a cytotoxic antibody response. To determine if cytotoxic anti-MHC antibodies generated in vivo following MHC-mismatched MSC injections are capable of initiating complement-dependent cytotoxicity of MSCs. Experimental controlled study. Antisera previously collected at Days 0, 7, 14 and 21 post-injection from 4 horses injected with donor MHC-mismatched equine leucocyte antigen (ELA)-A2 haplotype MSCs and one control horse injected with donor MHC-matched ELA-A2 MSCs were utilised in this study. Antisera were incubated with ELA-A2 MSCs before adding complement in microcytotoxicity assays and cell death was analysed via eosin dye exclusion. ELA-A2 peripheral blood leucocytes (PBLs) were used in the assays as a positive control. Antisera from all 4 horses injected with MHC-mismatched MSCs contained antibodies that caused the death of ELA-A2 haplotype MSCs in the microcytotoxicity assays. In 2 of the 4 horses, antibodies were present as early as Day 7 post-injection. MSC death was consistently equivalent to that of ELA-A2 haplotype PBL death at all time points and antisera dilutions. Antisera from the control horse that was injected with MHC-matched MSCs did not contain cytotoxic ELA-A2 antibodies at any of the time points examined. This study examined MSC death in vitro only and utilized antisera from a small number of horses. The cytotoxic antibody response induced in recipient horses following injection with donor MHC-mismatched MSCs is capable of killing donor MSCs in vitro. These results suggest that the use of allogeneic MHC-mismatched MSCs must be cautioned against, not only for potential adverse events, but also for reduced therapeutic efficacy due to targeted MSC death. © 2016 The

  20. Automatic Detection and Positioning of Ground Control Points Using TerraSAR-X Multiaspect Acquisitions

    Science.gov (United States)

    Montazeri, Sina; Gisinger, Christoph; Eineder, Michael; Zhu, Xiao xiang

    2018-05-01

    Geodetic stereo Synthetic Aperture Radar (SAR) is capable of absolute three-dimensional localization of natural Persistent Scatterer (PS)s which allows for Ground Control Point (GCP) generation using only SAR data. The prerequisite for the method to achieve high precision results is the correct detection of common scatterers in SAR images acquired from different viewing geometries. In this contribution, we describe three strategies for automatic detection of identical targets in SAR images of urban areas taken from different orbit tracks. Moreover, a complete work-flow for automatic generation of large number of GCPs using SAR data is presented and its applicability is shown by exploiting TerraSAR-X (TS-X) high resolution spotlight images over the city of Oulu, Finland and a test site in Berlin, Germany.

  1. Impact of point-of-sale tobacco display bans: findings from the International Tobacco Control Four Country Survey

    OpenAIRE

    Li, Lin; Borland, Ron; Fong, Geoffrey T.; Thrasher, James F.; Hammond, David; Cummings, Kenneth M.

    2013-01-01

    This study examined the impact of point-of-sale (POS) tobacco marketing restrictions in Australia and Canada, in relation to the United Kingdom and the United States where there were no such restrictions during the study period (2006–10). The data came from the International Tobacco Control Four Country Survey, a prospective multi-country cohort survey of adult smokers. In jurisdictions where POS display bans were implemented, smokers’ reported exposure to tobacco marketing declined markedly....

  2. Efficiency of stormwater control measures for combined sewer retrofitting under varying rain conditions: Quantifying the Three Points Approach (3PA)

    DEFF Research Database (Denmark)

    Sørup, Hjalte Jomo Danielsen; Lerer, Sara Maria; Arnbjerg-Nielsen, Karsten

    2016-01-01

    We present a method to assess and communicate the efficiency of stormwater control measures for retrofitting existing urban areas. The tool extends the Three Points Approach to quantitatively distinguish three rainfall domains: (A) rainwater resource utilisation, (B) urban stormwater drainage pipe......, stormwater drainage and flood risks....

  3. Controlled ion track etching

    Science.gov (United States)

    George, J.; Irkens, M.; Neumann, S.; Scherer, U. W.; Srivastava, A.; Sinha, D.; Fink, D.

    2006-03-01

    It is a common practice since long to follow the ion track-etching process in thin foils via conductometry, i.e . by measurement of the electrical current which passes through the etched track, once the track breakthrough condition has been achieved. The major disadvantage of this approach, namely the absence of any major detectable signal before breakthrough, can be avoided by examining the track-etching process capacitively. This method allows one to define precisely not only the breakthrough point before it is reached, but also the length of any non-transient track. Combining both capacitive and conductive etching allows one to control the etching process perfectly. Examples and possible applications are given.

  4. Microprocessor-controlled step-down maximum-power-point tracker for photovoltaic systems

    Science.gov (United States)

    Mazmuder, R. K.; Haidar, S.

    1992-12-01

    An efficient maximum power point tracker (MPPT) has been developed and can be used with a photovoltaic (PV) array and a load which requires lower voltage than the PV array voltage to be operated. The MPPT makes the PV array to operate at maximum power point (MPP) under all insolation and temperature, which ensures the maximum amount of available PV power to be delivered to the load. The performance of the MPPT has been studied under different insolation levels.

  5. Metal food packaging design based on hazard analysis critical control point (HACCP system in canned food safety

    Directory of Open Access Journals (Sweden)

    Li Xingyi

    2016-06-01

    Full Text Available This study aims to design metal food packaging with hazard analysis critical control point (HACCP. First, theory of HACCP was introduced in detail. Taking empty cans provided by Wuxi Huapeng Food Packaging Company as an example, we studied migration of bisphenol compounds in coating of food can to food stimulant. Moreover, packaging design of luncheon meat can was taken as an example to confirm whether HACCP system could effectively control migration of phenolic substance. Results demonstrated that, coating of such empty were more likely to contain multiple bisphenol compounds such as bisphenol A (BPA, and bisphenol A diglycidyl ether (BADGE was considered as the leading bisphenol pollutant; food stimulant of different types, storage temperature and time could all impact migration of bisphenol compounds. HACCP system was proved to be effective in controlling hazards of phenolic substance in luncheon meat can and could reduce various phenolic substance indexes to an acceptable range. Therefore, HACCP can control migration of phenolic substance and recontamination of food and thus ensure food safety.

  6. Design of the stabilizing control of the orbital motion in the vicinity of the collinear libration point L1 using the analytical representation of the invariant manifold

    Science.gov (United States)

    Maliavkin, G. P.; Shmyrov, A. S.; Shmyrov, V. A.

    2018-05-01

    Vicinities of collinear libration points of the Sun-Earth system are currently quite attractive for the space navigation. Today, various projects on placing of spacecrafts observing the Sun in the L1 libration point and telescopes in L2 have been implemented (e.g. spacecrafts "WIND", "SOHO", "Herschel", "Planck"). Collinear libration points being unstable leads to the problem of stabilization of a spacecraft's motion. Laws of stabilizing motion control in vicinity of L1 point can be constructed using the analytical representation of a stable invariant manifold. Efficiency of these control laws depends on the precision of the representation. Within the model of Hill's approximation of the circular restricted three-body problem in the rotating geocentric coordinate system one can obtain the analytical representation of an invariant manifold filled with bounded trajectories in a form of series in terms of powers of the phase variables. Approximate representations of the orders from the first to the fourth inclusive can be used to construct four laws of stabilizing feedback motion control under which trajectories approach the manifold. By virtue of numerical simulation the comparison can be made: how the precision of the representation of the invariant manifold influences the efficiency of the control, expressed by energy consumptions (characteristic velocity). It shows that using approximations of higher orders in constructing the control laws can significantly reduce the energy consumptions on implementing the control compared to the linear approximation.

  7. White matter correlates of impaired attention control in major depressive disorder and healthy volunteers.

    Science.gov (United States)

    Rizk, Mina M; Rubin-Falcone, Harry; Keilp, John; Miller, Jeffrey M; Sublette, M Elizabeth; Burke, Ainsley; Oquendo, Maria A; Kamal, Ahmed M; Abdelhameed, Mohamed A; Mann, J John

    2017-11-01

    Major depressive disorder (MDD) is associated with impaired attention control and alterations in frontal-subcortical connectivity. We hypothesized that attention control as assessed by Stroop task interference depends on white matter integrity in fronto-cingulate regions and assessed this relationship using diffusion tensor imaging (DTI) in MDD and healthy volunteers (HV). DTI images and Stroop task were acquired in 29 unmedicated MDD patients and 16 HVs, aged 18-65 years. The relationship between Stroop interference and fractional anisotropy (FA) was examined using region-of-interest (ROI) and tract-based spatial statistics (TBSS) analyses. ROI analysis revealed that Stroop interference correlated positively with FA in left caudal anterior cingulate cortex (cACC) in HVs (r = 0.62, p = 0.01), but not in MDD (r = -0.05, p= 0.79) even after controlling for depression severity. The left cACC was among 4 ROIs in fronto-cingulate network where FA was lower in MDD relative to HVs (F (1,41) = 8.87, p = 0.005). Additionally, TBSS showed the same group interaction of differences and correlations, although only at a statistical trend level. The modest sample size limits the generalizability of the findings. Structural connectivity of white matter network of cACC correlated with magnitude of Stroop interference in HVs, but not MDD. The cACC-frontal network, sub-serving attention control, may be disrupted in MDD. Less cognitive control may include enhanced effects of salience in HVs, or less effective response inhibition in MDD. Further studies of salience and inhibition components of executive function may better elucidate the relationship between brain white matter changes and executive dysfunction in MDD. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Identification of critical points of thermal environment in broiler production

    Directory of Open Access Journals (Sweden)

    AG Menezes

    2010-03-01

    Full Text Available This paper describes an exploratory study carried out to determine critical control points and possible risks in hatcheries and broiler farms. The study was based in the identification of the potential hazards existing in broiler production, from the hatchery to the broiler farm, identifying critical control points and defining critical limits. The following rooms were analyzed in the hatchery: egg cold storage, pre-heating, incubator, and hatcher rooms. Two broiler houses were studied in two different farms. The following data were collected in the hatchery and broiler houses: temperature (ºC and relative humidity (%, air velocity (m s-1, ammonia levels, and light intensity (lx. In the broiler house study, a questionnaire using information of the Broiler Production Good Practices (BPGP manual was applied, and workers were interviewed. Risk analysis matrices were build to determine Critical Control Points (CCP. After data collection, Statistical Process Control (SPC was applied through the analysis of the Process Capacity Index, using the software program Minitab15®. Environmental temperature and relative humidity were the critical points identified in the hatchery and in both farms. The classes determined as critical control points in the broiler houses were poultry litter, feeding, drinking water, workers' hygiene and health, management and biosecurity, norms and legislation, facilities, and activity planning. It was concluded that CCP analysis, associated with SPC control tools and guidelines of good production practices, may contribute to improve quality control in poultry production.

  9. Launching and controlling Gaussian beams from point sources via planar transformation media

    Science.gov (United States)

    Odabasi, Hayrettin; Sainath, Kamalesh; Teixeira, Fernando L.

    2018-02-01

    Based on operations prescribed under the paradigm of complex transformation optics (CTO) [F. Teixeira and W. Chew, J. Electromagn. Waves Appl. 13, 665 (1999), 10.1163/156939399X01104; F. L. Teixeira and W. C. Chew, Int. J. Numer. Model. 13, 441 (2000), 10.1002/1099-1204(200009/10)13:5%3C441::AID-JNM376%3E3.0.CO;2-J; H. Odabasi, F. L. Teixeira, and W. C. Chew, J. Opt. Soc. Am. B 28, 1317 (2011), 10.1364/JOSAB.28.001317; B.-I. Popa and S. A. Cummer, Phys. Rev. A 84, 063837 (2011), 10.1103/PhysRevA.84.063837], it was recently shown in [G. Castaldi, S. Savoia, V. Galdi, A. Alù, and N. Engheta, Phys. Rev. Lett. 110, 173901 (2013), 10.1103/PhysRevLett.110.173901] that a complex source point (CSP) can be mimicked by parity-time (PT ) transformation media. Such coordinate transformation has a mirror symmetry for the imaginary part, and results in a balanced loss/gain metamaterial slab. A CSP produces a Gaussian beam and, consequently, a point source placed at the center of such a metamaterial slab produces a Gaussian beam propagating away from the slab. Here, we extend the CTO analysis to nonsymmetric complex coordinate transformations as put forth in [S. Savoia, G. Castaldi, and V. Galdi, J. Opt. 18, 044027 (2016), 10.1088/2040-8978/18/4/044027] and verify that, by using simply a (homogeneous) doubly anisotropic gain-media metamaterial slab, one can still mimic a CSP and produce Gaussian beam. In addition, we show that a Gaussian-like beams can be produced by point sources placed outside the slab as well. By making use of the extra degrees of freedom (the real and imaginary parts of the coordinate transformation) provided by CTO, the near-zero requirement on the real part of the resulting constitutive parameters can be relaxed to facilitate potential realization of Gaussian-like beams. We illustrate how beam properties such as peak amplitude and waist location can be controlled by a proper choice of (complex-valued) CTO Jacobian elements. In particular, the beam waist

  10. Control Strategy of Two Capacitor Voltages for Separate MPPTs in Photovoltaic Systems Using Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Choi, Ui-Min; Blaabjerg, Frede; Lee, Kyo-Beum

    2015-01-01

    The centralized topology with three-level inverters are widely used in photovoltaic (PV) systems due to their less installation costs and complexity. However, the common maximum power point tracking (MPPT) is a disadvantage of the centralized topology particularly under the partial shading...... and panel mismatch conditions. In this system, if PV modules are separately connected to the split capacitor voltage, the MPPT efficiency can be improved by the proposed control strategy. By the proposed method, the two capacitor voltages can be controlled asymmetrically to perform the separate MPPTs...... of each PV module connected to separate capacitors. The outputs can be generated without distortion even if two capacitors are asymmetrically regulated. Simulation and experimental results verify the validity and feasibility of the proposed methods....

  11. Communication Needs Assessment for Distributed Turbine Engine Control

    Science.gov (United States)

    Culley, Dennis E.; Behbahani, Alireza R.

    2008-01-01

    Control system architecture is a major contributor to future propulsion engine performance enhancement and life cycle cost reduction. The control system architecture can be a means to effect net weight reduction in future engine systems, provide a streamlined approach to system design and implementation, and enable new opportunities for performance optimization and increased awareness about system health. The transition from a centralized, point-to-point analog control topology to a modular, networked, distributed system is paramount to extracting these system improvements. However, distributed engine control systems are only possible through the successful design and implementation of a suitable communication system. In a networked system, understanding the data flow between control elements is a fundamental requirement for specifying the communication architecture which, itself, is dependent on the functional capability of electronics in the engine environment. This paper presents an assessment of the communication needs for distributed control using strawman designs and relates how system design decisions relate to overall goals as we progress from the baseline centralized architecture, through partially distributed and fully distributed control systems.

  12. Rainfall Deduction Method for Estimating Non-Point Source Pollution Load for Watershed

    OpenAIRE

    Cai, Ming; Li, Huai-en; KAWAKAMI, Yoji

    2004-01-01

    The water pollution can be divided into point source pollution (PSP) and non-point source pollution (NSP). Since the point source pollution has been controlled, the non-point source pollution is becoming the main pollution source. The prediction of NSP load is being increasingly important in water pollution controlling and planning in watershed. Considering the monitoring data shortage of NPS in China, a practical estimation method of non-point source pollution load --- rainfall deduction met...

  13. Predicting Undergraduate Music Education Majors' Collegiate Achievement

    Science.gov (United States)

    Rohwer, Debbie

    2012-01-01

    In order for teachers to guide students in their preparation to be music majors, it would be useful to know those musical components that best predict overall collegiate success. The purpose of this study was to measure the relationship of predictor variables (Lessons, Music History, Music Theory, and Piano) to collegiate grade point average (GPA)…

  14. Psychosocial functioning in prepubertal major depressive disorders. II. Interpersonal relationships after sustained recovery from affective episode.

    Science.gov (United States)

    Puig-Antich, J; Lukens, E; Davies, M; Goetz, D; Brennan-Quattrock, J; Todak, G

    1985-05-01

    Psychosocial relationships with parents, peers, and siblings, as well as school functioning, were measured at two points in time by parental interview in 21 prepubertal children: during an episode of major depression and after they had sustained an affective recovery from the index episode for at least four months. School functioning was completely normalized, but deficits in the child's intrafamilial and extra-familial relationships had improved only partially. The pattern of improvement was merely quantitative. Moderate deficits during the depressive episode reached, after affective recovery, the level of the normal control group. In contrast, severe deficits only improved to a moderate level of severity. It is suggested that treating the affective disorder is not sufficient in many children with major depression and that efficacy studies of psychotherapeutic interventions in affectively recovered children are needed.

  15. Implementation of hazard analysis and critical control point (HACCP) in dried anchovy production process

    Science.gov (United States)

    Citraresmi, A. D. P.; Wahyuni, E. E.

    2018-03-01

    The aim of this study was to inspect the implementation of Hazard Analysis and Critical Control Point (HACCP) for identification and prevention of potential hazards in the production process of dried anchovy at PT. Kelola Mina Laut (KML), Lobuk unit, Sumenep. Cold storage process is needed in each anchovy processing step in order to maintain its physical and chemical condition. In addition, the implementation of quality assurance system should be undertaken to maintain product quality. The research was conducted using a survey method, by following the whole process of making anchovy from the receiving raw materials to the packaging of final product. The method of data analysis used was descriptive analysis method. Implementation of HACCP at PT. KML, Lobuk unit, Sumenep was conducted by applying Pre Requisite Programs (PRP) and preparation stage consisting of 5 initial stages and 7 principles of HACCP. The results showed that CCP was found in boiling process flow with significant hazard of Listeria monocytogenesis bacteria and final sorting process with significant hazard of foreign material contamination in the product. Actions taken were controlling boiling temperature of 100 – 105°C for 3 - 5 minutes and training for sorting process employees.

  16. The case for an internal dynamics model versus equilibrium point control in human movement.

    Science.gov (United States)

    Hinder, Mark R; Milner, Theodore E

    2003-06-15

    The equilibrium point hypothesis (EPH) was conceived as a means whereby the central nervous system could control limb movements by a relatively simple shift in equilibrium position without the need to explicitly compensate for task dynamics. Many recent studies have questioned this view with results that suggest the formation of an internal dynamics model of the specific task. However, supporters of the EPH have argued that these results are not incompatible with the EPH and that there is no reason to abandon it. In this study, we have tested one of the fundamental predictions of the EPH, namely, equifinality. Subjects learned to perform goal-directed wrist flexion movements while a motor provided assistance in proportion to the instantaneous velocity. It was found that the subjects stopped short of the target on the trials where the magnitude of the assistance was randomly decreased, compared to the preceding control trials (P = 0.003), i.e. equifinality was not achieved. This is contrary to the EPH, which predicts that final position should not be affected by external loads that depend purely on velocity. However, such effects are entirely consistent with predictions based on the formation of an internal dynamics model.

  17. The application of quality risk management to the bacterial endotoxins test: use of hazard analysis and critical control points.

    Science.gov (United States)

    Annalaura, Carducci; Giulia, Davini; Stefano, Ceccanti

    2013-01-01

    Risk analysis is widely used in the pharmaceutical industry to manage production processes, validation activities, training, and other activities. Several methods of risk analysis are available (for example, failure mode and effects analysis, fault tree analysis), and one or more should be chosen and adapted to the specific field where they will be applied. Among the methods available, hazard analysis and critical control points (HACCP) is a methodology that has been applied since the 1960s, and whose areas of application have expanded over time from food to the pharmaceutical industry. It can be easily and successfully applied to several processes because its main feature is the identification, assessment, and control of hazards. It can be also integrated with other tools, such as fishbone diagram and flowcharting. The aim of this article is to show how HACCP can be used to manage an analytical process, propose how to conduct the necessary steps, and provide data templates necessary to document and useful to follow current good manufacturing practices. In the quality control process, risk analysis is a useful tool for enhancing the uniformity of technical choices and their documented rationale. Accordingly, it allows for more effective and economical laboratory management, is capable of increasing the reliability of analytical results, and enables auditors and authorities to better understand choices that have been made. The aim of this article is to show how hazard analysis and critical control points can be used to manage bacterial endotoxins testing and other analytical processes in a formal, clear, and detailed manner.

  18. Administrative Lead Time at Navy Inventory Control Points

    National Research Council Canada - National Science Library

    Granetto, Paul

    1994-01-01

    .... We also evaluated the internal controls established for administrative lead time and the adequacy of management's implementation of the DoD Internal Management Control Program for monitoring administrative lead time...

  19. [Effect of ear point embedding on plasma and effect site concentrations of propofol-remifentanil in elderly patients after target-controlled induction].

    Science.gov (United States)

    Zheng, Xiaochun; Wan, Liling; Gao, Fei; Chen, Jianghu; Tu, Wenshao

    2017-08-12

    To observe the clinical effect of ear point embedding on plasma and effect site concentrations of propofol-remifentanil in elderly patients who underwent abdominal external hernia surgery at the time of consciousness and pain disappearing by target-controlled infusion (TCI) and bispectral index (BIS). Fifty patients who underwent elective abdominal hernia surgery were randomly assigned into an observation group and a control group, 25 cases in each one. In the observation group, 30 minutes before anesthesia induction, Fugugou (Extra), Gan (CO 12 ), Pizhixia (AT 4 ), and Shenmen (TF 4 ) were embedded by auricular needles until the end of surgery, 10 times of counter press each point. In the control group, the same amount of auricular tape was applied until the end of surgery at the same points without stimulation 30 minutes before anesthesia induction. Patients in the two groups were given total intravenous anesthesia, and BIS was monitored by BIS anesthesia depth monitor. Propofol was infused by TCI at a beginning concentration of 1.5μg/L and increased by 0.3μg/L every 30s until the patients lost their consciousness. After that, remifentanil was infused by TCI at a beginning concentration of 2.0μg/L and increased by 0.3μg/L every 30s until the patients had no body reaction to pain stimulation (orbital reflex). Indices were recorded, including mean arterial pressure (MAP), heart rate (HR) and the BIS values, at the time of T 0 (entering into the operation room), T 1 (losing consciousness) and T 2 (pain relief), the plasma and effect site concentrations of propofol at T 1 , the plasma and effect site concentrations of remifentanil at T 2 . After surgery we recorded the total amounts of propofol and remifentanil, surgery time and anesthesia time. At T 1 and T 2 , MAP and HR of the observation group were higher than those of the control group ( P effect site concentrations of propofol in the observation group were significantly lower than those in the control group

  20. Freezing point osmometry of milk to determine the additional water content – an issue in general quality control and German food regulation

    Directory of Open Access Journals (Sweden)

    Holz Birger

    2008-03-01

    Full Text Available Abstract Background The determination of the osmolality of aqueous samples using a freezing point osmometer is a well-established, routine laboratory method. In addition to their use in clinical and pharmaceutical laboratories, freezing point osmometers are also employed in food testing laboratories. One application is the determination of the osmolality of milk. Although cow's milk is a natural product whose water content is approximately 87%, the osmolality of milk is a significant value when the milk is collected from a larger population of animals. This value is used in milk processing to control the water content, based on the German Food Control Regulations for Milk. Results Measurement of the freezing point and osmolality of milk samples was performed with a Knauer Semi-Micro Freezing Point Osmometer. Osmolality was measured for the untreated milk samples and following their dilution (by volume with 10% and 50% water. The measurements were made after 1, 4 and 7 days to evaluate changes over time. All measurement values for the undiluted milk were spread over a small interval with an average of 271 mOsmol/kg. After mixing the milk samples with 10% water, the average decreased to 242 mOsmol/kg, while mixing with 50% water resulted in an average osmolality of 129 mOsmol/kg. There was no significant change for the osmolality within the 7 days (measurements from days 1, 4 and 7. Conclusion The results observed demonstrate clearly that the additional water content of milk can be determined easily using a freezing point osmometer. Milk samples that contain additional water have a significantly decreased osmolality, corresponding to an increased freezing point. The effect on osmolality of ageing the milk samples could not be determined in this study's time-dependent measurements.

  1. How compliant are tobacco vendors to india's tobacco control legislation on Ban of advertisments at point of sale? A three jurisdictions review.

    Science.gov (United States)

    Goel, Sonu; Kumar, Ravinder; Lal, Pranay; Tripathi, Jp; Singh, Rana J; Rathinam, Arul; Christian, Anant

    2014-01-01

    Section 5 of India's tobacco control legislation "Cigarettes and Other Tobacco Products Act (COTPA), 2003"comprehensively prohibits all kinds of tobacco advertisement, promotion and sponsorship (TAPS), but permits advertisments at the point-of-sale (POS) under certain conditions. This provision has been exploited by the tobacco companies to promote their products. To measure compliance with the provisions of Section 5 of Indian tobacco control legislation (COTPA, 2003) at point of sale. A cross-sectional survey using an observation checklist was conducted in 1860 POS across three jurisdictions (Chennai city, District Vadodara and District Mohali) in India. The most common mode of advertisement of tobacco products was product showcasing (51.1%), followed by dangles (49.6%), stickers (33.8%) and boards (27.1%). More than one fourth of POS were found violating legal provisions for displaying advertisement boards in one or other forms (oversized, extended to full body lenth of POS, displayed brandname/ packshot and promotional messages). Advertisement boards (16.3%) without health warnings were also found and wherever found, more than 90% health warning were not as per the specification in respect to size, font and background color. Point of sale advertising is aggressively used by the tobacco industry to promote their products. There is an urgent need of effective implementation of a comprehensive ban on tobacco product advertisement, promotion and sponsorship at point of sale.

  2. Serious gaming technology in major incident triage training: a pragmatic controlled trial.

    Science.gov (United States)

    Knight, James F; Carley, Simon; Tregunna, Bryan; Jarvis, Steve; Smithies, Richard; de Freitas, Sara; Dunwell, Ian; Mackway-Jones, Kevin

    2010-09-01

    By exploiting video games technology, serious games strive to deliver affordable, accessible and usable interactive virtual worlds, supporting applications in training, education, marketing and design. The aim of the present study was to evaluate the effectiveness of such a serious game in the teaching of major incident triage by comparing it with traditional training methods. Pragmatic controlled trial. During Major Incident Medical Management and Support Courses, 91 learners were randomly distributed into one of two training groups: 44 participants practiced triage sieve protocol using a card-sort exercise, whilst the remaining 47 participants used a serious game. Following the training sessions, each participant undertook an evaluation exercise, whereby they were required to triage eight casualties in a simulated live exercise. Performance was assessed in terms of tagging accuracy (assigning the correct triage tag to the casualty), step accuracy (following correct procedure) and time taken to triage all casualties. Additionally, the usability of both the card-sort exercise and video game were measured using a questionnaire. Tagging accuracy by participants who underwent the serious game training was significantly higher than those who undertook the card-sort exercise [Chi2=13.126, p=0.02]. Step accuracy was also higher in the serious game group but only for the numbers of participants that followed correct procedure when triaging all eight casualties [Chi2=5.45, p=0.0196]. There was no significant difference in time to triage all casualties (card-sort=435+/-74 s vs video game=456+/-62 s, p=0.155). Serious game technologies offer the potential to enhance learning and improve subsequent performance when compared to traditional educational methods. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Dynamics and control of high area-to-mass ratio spacecraft and its application to geomagnetic exploration

    Science.gov (United States)

    Luo, Tong; Xu, Ming; Colombo, Camilla

    2018-04-01

    This paper studies the dynamics and control of a spacecraft, whose area-to-mass ratio is increased by deploying a reflective orientable surface such as a solar sail or a solar panel. The dynamical system describing the motion of a non-zero attitude angle high area-to-mass ratio spacecraft under the effects of the Earth's oblateness and solar radiation pressure admits the existence of equilibrium points, whose number and the eccentricity values depend on the semi-major axis, the area-to-mass ratio and the attitude angle of the spacecraft together. When two out of three parameters are fixed, five different dynamical topologies successively occur through varying the third parameter. Two of these five topologies are critical cases characterized by the appearance of the bifurcation phenomena. A conventional Hamiltonian structure-preserving (HSP) controller and an improved HSP controller are both constructed to stabilize the hyperbolic equilibrium point. Through the use of a conventional HSP controller, a bounded trajectory around the hyperbolic equilibrium point is obtained, while an improved HSP controller allows the spacecraft to easily transfer to the hyperbolic equilibrium point and to follow varying equilibrium points. A bifurcation control using topologies and changes of behavior areas can also stabilize a spacecraft near a hyperbolic equilibrium point. Natural trajectories around stable equilibrium point and these stabilized trajectories around hyperbolic equilibrium point can all be applied to geomagnetic exploration.

  4. DETECTION OF SLOPE MOVEMENT BY COMPARING POINT CLOUDS CREATED BY SFM SOFTWARE

    Directory of Open Access Journals (Sweden)

    K. Oda

    2016-06-01

    Full Text Available This paper proposes movement detection method between point clouds created by SFM software, without setting any onsite georeferenced points. SfM software, like Smart3DCaputure, PhotoScan, and Pix4D, are convenient for non-professional operator of photogrammetry, because these systems require simply specification of sequence of photos and output point clouds with colour index which corresponds to the colour of original image pixel where the point is projected. SfM software can execute aerial triangulation and create dense point clouds fully automatically. This is useful when monitoring motion of unstable slopes, or loos rocks in slopes along roads or railroads. Most of existing method, however, uses mesh-based DSM for comparing point clouds before/after movement and it cannot be applied in such cases that part of slopes forms overhangs. And in some cases movement is smaller than precision of ground control points and registering two point clouds with GCP is not appropriate. Change detection method in this paper adopts CCICP (Classification and Combined ICP algorithm for registering point clouds before / after movement. The CCICP algorithm is a type of ICP (Iterative Closest Points which minimizes point-to-plane, and point-to-point distances, simultaneously, and also reject incorrect correspondences based on point classification by PCA (Principle Component Analysis. Precision test shows that CCICP method can register two point clouds up to the 1 pixel size order in original images. Ground control points set in site are useful for initial setting of two point clouds. If there are no GCPs in site of slopes, initial setting is achieved by measuring feature points as ground control points in the point clouds before movement, and creating point clouds after movement with these ground control points. When the motion is rigid transformation, in case that a loose Rock is moving in slope, motion including rotation can be analysed by executing CCICP for a

  5. Relationship between cardiac vagal activity and mood congruent memory bias in major depression.

    Science.gov (United States)

    Garcia, Ronald G; Valenza, Gaetano; Tomaz, Carlos A; Barbieri, Riccardo

    2016-01-15

    Previous studies suggest that autonomic reactivity during encoding of emotional information could modulate the neural processes mediating mood-congruent memory. In this study, we use a point-process model to determine dynamic autonomic tone in response to negative emotions and its influence on long-term memory of major depressed subjects. Forty-eight patients with major depression and 48 healthy controls were randomly assigned to either neutral or emotionally arousing audiovisual stimuli. An adaptive point-process algorithm was applied to compute instantaneous estimates of the spectral components of heart rate variability [Low frequency (LF), 0.04-0.15 Hz; High frequency (HF), 0.15-0.4 Hz]. Three days later subjects were submitted to a recall test. A significant increase in HF power was observed in depressed subjects in response to the emotionally arousing stimulus (p=0.03). The results of a multivariate analysis revealed that the HF power during the emotional segment of the stimulus was independently associated with the score of the recall test in depressed subjects, after adjusting for age, gender and educational level (Coef. 0.003, 95%CI, 0.0009-0.005, p=0.008). These results could only be interpreted as responses to elicitation of specific negative emotions, the relationship between HF changes and encoding/recall of positive stimuli should be further examined. Alterations on parasympathetic response to emotion are involved in the mood-congruent cognitive bias observed in major depression. These findings are clinically relevant because it could constitute the mechanism by which depressed patients maintain maladaptive patterns of negative information processing that trigger and sustain depressed mood. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Maximum power point tracker for photovoltaic power plants

    Science.gov (United States)

    Arcidiacono, V.; Corsi, S.; Lambri, L.

    The paper describes two different closed-loop control criteria for the maximum power point tracking of the voltage-current characteristic of a photovoltaic generator. The two criteria are discussed and compared, inter alia, with regard to the setting-up problems that they pose. Although a detailed analysis is not embarked upon, the paper also provides some quantitative information on the energy advantages obtained by using electronic maximum power point tracking systems, as compared with the situation in which the point of operation of the photovoltaic generator is not controlled at all. Lastly, the paper presents two high-efficiency MPPT converters for experimental photovoltaic plants of the stand-alone and the grid-interconnected type.

  7. TMACS I/O termination point listing. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Scaief, C.C. III

    1994-09-13

    This document provides a listing of all analog and discrete input/output (I/O) points connected to the Tank Monitor and Control System (TMACS). The list also provides other information such as the point tag name, termination location, description, drawing references and other parameters. The purpose is to define each point`s unique tag name and to cross reference the point with other associated information that may be necessary for activities such as maintenance, calibration, diagnostics, or design changes. It provides a list in one document of all I/O points that would otherwise only be available by referring to all I/O termination drawings.

  8. Major unsolved points in adult neurogenesis: doors open on a translational future?

    Directory of Open Access Journals (Sweden)

    Paolo ePeretto

    2014-06-01

    Full Text Available The ultimate goal of exploiting adult neurogenesis (AN as a source of cell replacement is far from being achieved. In spite of many data gathered during the last two decades on homeostatic and reactive neurogenesis, it is evident that such knowledge is not sufficient for granting translational outcomes. By asking the question whether AN research field has to be considered as a dead end in such a perspective, here we review some major unresolved issues: multifaceted evolutionary constraints emerged in mammals, stem/progenitor cell type/availability and tissue permissivity, the possible impact on other brain functions and/or interplay with other forms of plasticity, and relevance in humans. We suggest that full understanding of AN biological processes is an essential step to their possible exploitation for brain repair, and that further fundamental, multidisciplinary research is required before translational outcomes can be reached. Scientist's attitude and their communication skills are also important. To avoid overestimation of AN reparative potential, more distant goals of cell replacement should be kept clearly distinct from restorative approaches involving AN plasticity, both representing translational perspectives.

  9. A Randomized Double-Blind Sham-Controlled Study of Transcranial Direct Current Stimulation for Treatment-Resistant Major Depression

    Directory of Open Access Journals (Sweden)

    Daniel eBlumberger

    2012-08-01

    Full Text Available Objectives: Transcranial direct current stimulation (tDCS has demonstrated some efficacy in treatment-resistant major depression (TRD. The majority of previous controlled studies have used anodal stimulation to the left dorsolateral prefrontal cortex (DLPFC and a control location such as the supraorbital region on for the cathode. Several open label studies have suggested effectiveness from anodal stimulation to the left DLPFC combined with cathodal stimulation to the right DLPFC. Thus, this study evaluated the efficacy of tDCS using anodal stimulation to the left DLPFC and cathodal stimulation to the right DLPFC compared to sham tDCS. Methods: Subjects between the ages of 18 and 65 were recruited from a tertiary care university hospital. Twenty-four subjects with TRD and a 17-item Hamilton Depression Rating Scale (HDRS greater than 21 were randomized to receive tDCS or sham tDCS. The rates of remission were compared between the two treatment groups.Results: The remission rates did not differ significantly between the two groups using an intention to treat analysis. More subjects in the active tDCS group had failed a course of electroconvulsive therapy in the current depressive episode. Side effects did not differ between the two groups and in general the treatment was very well tolerated. Conclusion: Anodal stimulation to the left DLPFC and cathodal stimulation to the right DLPFC was not efficacious in TRD. However, a number of methodological limitations warrant caution in generalizing from this study. Ongoing, controlled studies should provide further clarification on the efficacy of this stimulation configuration in TRD.

  10. The Apache Point Observatory Galactic Evolution Experiment (APOGEE)

    DEFF Research Database (Denmark)

    Majewski, Steven R.; Schiavon, Ricardo P.; Frinchaboy, Peter M.

    2017-01-01

    The Apache Point Observatory Galactic Evolution Experiment (APOGEE), one of the programs in the Sloan Digital Sky Survey III (SDSS-III), has now completed its systematic, homogeneous spectroscopic survey sampling all major populations of the Milky Way. After a three-year observing campaign on the...

  11. DETERMINATION OF THE EFFICACY OF BEST ACTION, FURADAN, AND NEEM EMULSION IN THE CONTROL OF MAJOR INSECT PESTS OF COWPEA [Vigna unguiculata (L. WALP

    Directory of Open Access Journals (Sweden)

    2016-11-01

    Full Text Available Field experiments to determine the efficacy of Best Action (30g/litre cypermethrine plus 250g/litre dimethoate as water emulsifiable concentrates, Furadan 10G (carbofuran, Neem emulsion (Azadiracta indica as insecticide treatments in the control of major insect pests of cowpea were conducted in two agro-environments simultaneously in Enugu Area, South Eastern Nigeria in 2014 cropping season using two cowpea varieties (Ife brown, and Potiskum as test crops. The experimental design was a split plot in a randomized compete block (RCB replicated three times. Best Action was more effective in controlling cowpea insect pests, followed by Furandan 10G, and Neem emulsion respectively and their effectiveness was not affected by climatic factors variations in the two agro-environments (Nsukka and Agbani. Ife brown and Potiskum did not significantly resist the attack of major insect pests of cowpea. Insecticides and cowpea varieties did not have a significant interaction effect on the control of major insect pests of cowpea.

  12. Trace elements status in children with B-thalassaemia major

    International Nuclear Information System (INIS)

    Moawad, A.T.

    2005-01-01

    This study was conducted on 30 children suffering from ft-thalassaemia major (15 males and 15 females) with mean age of 10.3 ± 5.1 years and 17 apparently healthy children with the same age and sex and served as controls. Patients as well as controls were subjected to careful history, clinical examination and laboratoiy investigations. Patients with jB-thalassaemia major had low body mass index (BMI) of 15.6± 3.5 compared to 19.5± 3.7 for the control (P<0.05). Hematological profile revealed that the mean This study was conducted on 30 children suffering from ft-thalassaemia major (15 males and 15 females) with mean age of 10.3 ± 5.1 years and 17 apparently healthy children with the same age and sex and served as controls. Patients as well as controls were subjected to careful history, clinical examination and laboratoiy investigations. Patients with jB-thalassaemia major had low body mass index (BMI) of 15.6± 3.5 compared to 19.5 ± 3.7 for the control (P<0.05). Hematological profile revealed that the mean

  13. Major Refurbishment of the University of Florida Training Reactor

    International Nuclear Information System (INIS)

    Joradn, Kelly; Berglund, Matthew; Shea, Brian

    2013-01-01

    The research reactor fleet is aging with few replacements being built. At the same time the technology for refurbishment of the older reactors has advanced well beyond that of currently installed equipment. The disparity between new and old technology results in an inability to find simple replacements for the older, highly integrated components. The lack of comprehensive guidance for digital equipment adds to the technical problems of installing individual replacement parts. Up to this point, no U. S. facilities have attempted a complete modernization effort because of the time commitment, financial burden, and licensing required for a total upgrade. The University of Florida Training Reactor is tackling this problem with a replacement of nearly all of the major facility sub-systems, including electrical distribution, reactor controls, nuclear instrumentation, security, building management, and environmental controls. This approach offers increased flexibility over the piece-by-piece replacement method by leveraging modern control systems based on global standards and capable of good data interchange with higher levels of redundancy. The UFTR reviewed numerous technologies to arrive at the final system architecture and this 'clean-slate' installation methodology. It is this concept of total system replacement and strict use of modular, open-standards technology that has allowed for a facility design that will be easy to install, maintain, and build upon over time

  14. Major Refurbishment of the University of Florida Training Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Joradn, Kelly; Berglund, Matthew; Shea, Brian [Univ., of Florida, Florida (United States)

    2013-07-01

    The research reactor fleet is aging with few replacements being built. At the same time the technology for refurbishment of the older reactors has advanced well beyond that of currently installed equipment. The disparity between new and old technology results in an inability to find simple replacements for the older, highly integrated components. The lack of comprehensive guidance for digital equipment adds to the technical problems of installing individual replacement parts. Up to this point, no U. S. facilities have attempted a complete modernization effort because of the time commitment, financial burden, and licensing required for a total upgrade. The University of Florida Training Reactor is tackling this problem with a replacement of nearly all of the major facility sub-systems, including electrical distribution, reactor controls, nuclear instrumentation, security, building management, and environmental controls. This approach offers increased flexibility over the piece-by-piece replacement method by leveraging modern control systems based on global standards and capable of good data interchange with higher levels of redundancy. The UFTR reviewed numerous technologies to arrive at the final system architecture and this 'clean-slate' installation methodology. It is this concept of total system replacement and strict use of modular, open-standards technology that has allowed for a facility design that will be easy to install, maintain, and build upon over time.

  15. Effect of perioperative beta blockade in patients with diabetes undergoing major non-cardiac surgery: randomised placebo controlled, blinded multicentre trial

    DEFF Research Database (Denmark)

    Juul, Anne Benedicte; Wetterslev, Jørn; Gluud, Christian

    2006-01-01

    Objectives To evaluate the long term effects of perioperative blockade on mortality and cardiac morbidity in patients with diabetes undergoing major non-cardiac surgery. Design Randomised placebo controlled and blinded multicentre trial. Analyses were by intention to treat. Setting University...

  16. Microbiological performance of Hazard Analysis Critical Control Point (HACCP)-based food safety management systems: A case of Nile perch processing company

    NARCIS (Netherlands)

    Kussaga, J.B.; Luning, P.A.; Tiisekwa, B.P.M.; Jacxsens, L.

    2017-01-01

    This study aimed at giving insight into microbiological safety output of a Hazard Analysis Critical Control Point (HACCP)-based Food Safety Management System (FSMS) of a Nile perch exporting company by using a combined assessment, This study aimed at giving insight into microbiological safety output

  17. Recombinant human G6PD for quality control and quality assurance of novel point-of-care diagnostics for G6PD deficiency.

    Directory of Open Access Journals (Sweden)

    Maria Kahn

    Full Text Available A large gap for the support of point-of-care testing is the availability of reagents to support quality control (QC of diagnostic assays along the supply chain from the manufacturer to the end user. While reagents and systems exist to support QC of laboratory screening tests for glucose-6-phosphate dehydrogenase (G6PD deficiency, they are not configured appropriately to support point-of-care testing. The feasibility of using lyophilized recombinant human G6PD as a QC reagent in novel point-of-care tests for G6PD deficiency is demonstrated.Human recombinant G6PD (r-G6PD was expressed in Escherichia coli and purified. Aliquots were stored at -80°C. Prior to lyophilization, aliquots were thawed, and three concentrations of r-G6PD (representing normal, intermediate, and deficient clinical G6PD levels were prepared and mixed with a protective formulation, which protects the enzyme activity against degradation from denaturation during the lyophilization process. Following lyophilization, individual single-use tubes of lyophilized r-G6PD were placed in individual packs with desiccants and stored at five temperatures for one year. An enzyme assay for G6PD activity was used to ascertain the stability of r-G6PD activity while stored at different temperatures.Lyophilized r-G6PD is stable and can be used as a control indicator. Results presented here show that G6PD activity is stable for at least 365 days when stored at -80°C, 4°C, 30°C, and 45°C. When stored at 55°C, enzyme activity was found to be stable only through day 28.Lyophilized r-G6PD enzyme is stable and can be used as a control for point-of-care tests for G6PD deficiency.

  18. Smart Global Maximum Power Point Tracking Controller of Photovoltaic Module Arrays

    Directory of Open Access Journals (Sweden)

    Long-Yi Chang

    2018-03-01

    Full Text Available This study first explored the effect of shading on the output characteristics of modules in a photovoltaic module array. Next, a modified particle swarm optimization (PSO method was employed to track the maximum power point of the multiple-peak characteristic curve of the array. Through the optimization method, the weighting value and cognition learning factor decreased with an increasing number of iterations, whereas the social learning factor increased, thereby enhancing the tracking capability of a maximum power point tracker. In addition, the weighting value was slightly modified on the basis of the changes in the slope and power of the characteristic curve to increase the tracking speed and stability of the tracker. Finally, a PIC18F8720 microcontroller was coordinated with peripheral hardware circuits to realize the proposed PSO method, which was then adopted to track the maximum power point of the power–voltage (P–V output characteristic curve of the photovoltaic module array under shading. Subsequently, tests were conducted to verify that the modified PSO method exhibited favorable tracking speed and accuracy.

  19. Motivation and academic performance of medical students from ethnic minorities and majority: a comparative study.

    Science.gov (United States)

    Isik, Ulviye; Wouters, Anouk; Ter Wee, Marieke M; Croiset, Gerda; Kusurkar, Rashmi A

    2017-11-28

    Medical students from ethnic minorities underperform in knowledge and skills assessments both in pre-clinical and clinical education compared to the ethnic majority group. Motivation, which influences learning and academic performance of medical students, might play an important role in explaining these differences, but is under-investigated. This study aimed to compare two types of motivation (autonomous and controlled) of ethnic minority (Western and non-Western) and majority (Dutch) students, and their association with academic performance. In a cross-sectional study, all students of a Dutch medical school were invited to complete a survey including the Academic Self-Regulation Questionnaire, measuring autonomous and controlled motivation, in the academic year 2015-2016. Motivation was compared using Kruskal-Wallis test and performance was compared using One-Way ANOVA. Linear regression analysis was used to determine the association between motivation and performance (grade point average; GPA). The response rate was 38.6% (n = 947). Autonomous motivation (AM) of non-Western students was higher than that of Dutch students in pre-clinical and clinical education (p motivation was higher in Western students than in Dutch students (pre-clinical education; p motivation between the ethnic majority and minority groups. The association of motivation with performance also differs between ethnic groups. We found that AM has a positive influence on GPA. Further research is needed to uncover the underlying mechanisms.

  20. Risk management: Role of societal factors in major industrial accidents

    International Nuclear Information System (INIS)

    Hovden, J.; Rausand, M.; Sergeev, G.

    1995-01-01

    The paper discusses factors influencing the occurrence of major accidents in complex technological systems. Societal factors are identified as most significant in this context. Important types of societal factors are pin-pointed and discussed. The safety situation in the former Soviet Union and in today's Russian is described. The calamities at Chernobyl, Three Mile Island, and partly also Bhopal are discussed, and the role of societal factors identified. A main point of view is that it is not surprising that these catastrophes happened in the then existing conditions. What is surprising is that they did not happen earlier exclamation point

  1. A randomized, controlled study evaluating effects of amlodipine addition to chelators to reduce iron loading in patients with thalassemia major.

    Science.gov (United States)

    Eghbali, Aziz; Kazemi, Hamideh; Taherahmadi, Hassan; Ghandi, Yazdan; Rafiei, Mohammad; Bagheri, Bahador

    2017-12-01

    Cardiomyopathy due to iron overload can be fatal in patients with thalassemia major. Calcium channel blockers seem to be effective to reduce iron loading. Our goal was to study effects of amlodipine addition to chelators on iron loading in patients with thalassemia major. This randomized, controlled, and single-center trial was performed on 56 patients with thalassemia major. Patients were randomized 1:1 to combined group (iron chelator plus amlodipine) or control group (iron chelator) for 1 year. Iron content was measured by magnetic resonance imaging; heart T2*, and liver T2*. Serum ferritin was also measured. After 12 months of treatment, myocardial T2* values had significant improvement in combined group (21.9 ± 8.0 ms to 24.5 ± 7.6 ms; P < .05); Difference between two groups was significant (P = .02). Combined treatment had no effect on hepatic T2* value (9.6 ± 2.8 ms to 9.5 ± 3.6 ms); difference between two groups was not significant (P = .2). In addition, a significant reduction was seen in serum ferritin levels in two groups. Mild gastrointestinal upset was the most common untoward effect. Addition of amlodipine to iron chelators has beneficial effects for reduction of iron loading in patients with thalassemia major. This combination therapy seems safe. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. PENERAPAN SISTEM HAZARD ANALYSIS CRITICAL CONTROL POINT (HACCP PADA PROSES PEMBUATAN KERIPIK TEMPE

    Directory of Open Access Journals (Sweden)

    Rahmi Yuniarti

    2015-06-01

    Full Text Available Malang is one of the industrial centers of tempe chips. To maintain the quality and food safety, analysis is required to identify the hazards during the production process. This study was conducted to identify the hazards during the production process of tempe chips and provide recommendations for developing a HACCP system. The phases of production process of tempe chips are started from slice the tempe, move it to the kitchen, coat it with flour dough, fry it in the pan, drain it, package it, and then storage it. There are 3 types of potential hazards in terms of biological, physical, and chemical during the production process. With the CCP identification, there are three processes that have Critical Control Point. There are the process of slicing tempe, immersion of tempe into the flour mixture and draining. Recommendations for the development of HACCP systems include recommendations related to employee hygiene, supporting equipment, 5-S analysis, and the production layout.

  3. Radiological signs pointing to altered correlations between heart and major vessels, esophagus and trachea

    International Nuclear Information System (INIS)

    Frantsov, S.

    1993-01-01

    A number of rather frequently encountered varieties and anomalies, involving heart and major vessels, esophagus, trachea, lungs and their X-ray images, are outlined. The study rests on rich experience with X-ray diagnosis of congenital cardiovascular malformations and acquired heart defects, and considers their complexity and difficult differential diagnosis. The radiological signs and diagnostic algorithm of examination are described, followed by a discussion of the differential diagnosis. The author's experience is based on X-ray diagnosis verified during operation. 9 refs., 1 fig. (orig.)

  4. ATS-6 engineering performance report. Volume 2: Orbit and attitude controls

    Science.gov (United States)

    Wales, R. O. (Editor)

    1981-01-01

    Attitude control is reviewed, encompassing the attitude control subsystem, spacecraft attitude precision pointing and slewing adaptive control experiment, and RF interferometer experiment. The spacecraft propulsion system (SPS) is discussed, including subsystem, SPS design description and validation, orbital operations and performance, in-orbit anomalies and contingency operations, and the cesium bombardment ion engine experiment. Thruster failure due to plugging of the propellant feed passages, a major cause for mission termination, are considered among the critical generic failures on the satellite.

  5. Material-Point Analysis of Large-Strain Problems

    DEFF Research Database (Denmark)

    Andersen, Søren

    The aim of this thesis is to apply and improve the material-point method for modelling of geotechnical problems. One of the geotechnical phenomena that is a subject of active research is the study of landslides. A large amount of research is focused on determining when slopes become unstable. Hence......, it is possible to predict if a certain slope is stable using commercial finite element or finite difference software such as PLAXIS, ABAQUS or FLAC. However, the dynamics during a landslide are less explored. The material-point method (MPM) is a novel numerical method aimed at analysing problems involving...... materials subjected to large strains in a dynamical time–space domain. This thesis explores the material-point method with the specific aim of improving the performance for geotechnical problems. Large-strain geotechnical problems such as landslides pose a major challenge to model numerically. Employing...

  6. Equilibrium point control of a monkey arm simulator by a fast learning tree structured artificial neural network.

    Science.gov (United States)

    Dornay, M; Sanger, T D

    1993-01-01

    A planar 17 muscle model of the monkey's arm based on realistic biomechanical measurements was simulated on a Symbolics Lisp Machine. The simulator implements the equilibrium point hypothesis for the control of arm movements. Given initial and final desired positions, it generates a minimum-jerk desired trajectory of the hand and uses the backdriving algorithm to determine an appropriate sequence of motor commands to the muscles (Flash 1987; Mussa-Ivaldi et al. 1991; Dornay 1991b). These motor commands specify a temporal sequence of stable (attractive) equilibrium positions which lead to the desired hand movement. A strong disadvantage of the simulator is that it has no memory of previous computations. Determining the desired trajectory using the minimum-jerk model is instantaneous, but the laborious backdriving algorithm is slow, and can take up to one hour for some trajectories. The complexity of the required computations makes it a poor model for biological motor control. We propose a computationally simpler and more biologically plausible method for control which achieves the benefits of the backdriving algorithm. A fast learning, tree-structured network (Sanger 1991c) was trained to remember the knowledge obtained by the backdriving algorithm. The neural network learned the nonlinear mapping from a 2-dimensional cartesian planar hand position (x,y) to a 17-dimensional motor command space (u1, . . ., u17). Learning 20 training trajectories, each composed of 26 sample points [[x,y], [u1, . . ., u17] took only 20 min on a Sun-4 Sparc workstation. After the learning stage, new, untrained test trajectories as well as the original trajectories of the hand were given to the neural network as input. The network calculated the required motor commands for these movements. The resulting movements were close to the desired ones for both the training and test cases.

  7. Point shear wave elastography of the pancreas in patients with cystic fibrosis: a comparison with healthy controls.

    Science.gov (United States)

    Pfahler, Matthias Hermann Christian; Kratzer, Wolfgang; Leichsenring, Michael; Graeter, Tilmann; Schmidt, Stefan Andreas; Wendlik, Inka; Lormes, Elisabeth; Schmidberger, Julian; Fabricius, Dorit

    2018-02-19

    Manifestations of cystic fibrosis in the pancreas are gaining in clinical importance as patients live longer. Conventional ultrasonography and point shear wave elastography (pSWE) imaging are non-invasive and readily available diagnostic methods that are easy to perform. The aim of this study was to perform conventional ultrasonography and obtain pSWE values in the pancreases of patients with cystic fibrosis and to compare the findings with those of healthy controls. 27 patients with cystic fibrosis (13 women/14 men; mean age 27.7 ± 13.7 years; range 9-58 years) and 60 healthy control subjects (30 women/30 men; mean age 30.3 ± 10.0 years; range 22-55 years) underwent examinations of the pancreas with conventional ultrasound and pSWE imaging. Patients with cystic fibrosis have an echogenic pancreatic parenchyma. We found cystic lesions of the pancreas in six patients. pSWE imaging of the pancreatic parenchyma gave significantly lower shear wave velocities in patients with cystic fibrosis than in the control group (1.01 m/s vs 1.30 m/s; p cystic fibrosis than in a healthy control population.

  8. Successful Control of Major Project Budgets

    Directory of Open Access Journals (Sweden)

    Steen Lichtenberg

    2016-07-01

    Full Text Available This paper differs from scientific papers describing current research. In line with the theme of this special issue, it challenges conventional risk management practice against the background of former research results successfully finished decades ago. It is well-known that conventional practice frequently results in budget overruns of large projects. International reviews document that. Severe delays of schedules are also well-known. This paper describes successful research results from almost three decades ago, which successfully challenges this severe problem and has led to new practices. The research involved is an unusual mix: Scandinavian researchers from psychology, statistical theory and engineering economy. The resulting procedure has been widely used since around 1990 and challenges conventional procedures. The procedure is documented to be able to yield statistically correct prognoses, when the “rules of the game” have been correctly followed. After a short summary of the basic situation, this paper summarizes the research, followed by some resulting experiences, focusing on two recent studies each of 40 infrastructures and other major projects. In both sets, the actual final cost largely equaled the expected project cost. This result is a marked change from international past and present experience. Finally, the need for further research and progress is discussed.

  9. Metabolic syndrome in patients with bipolar disorder: comparison with major depressive disorder and non-psychiatric controls.

    Science.gov (United States)

    Silarova, Barbora; Giltay, Erik J; Van Reedt Dortland, Arianne; Van Rossum, Elisabeth F C; Hoencamp, Erik; Penninx, Brenda W J H; Spijker, Annet T

    2015-04-01

    We aimed to investigate the prevalence of the metabolic syndrome (MetS) and its individual components in subjects with bipolar disorder (BD) compared to those with major depressive disorder (MDD) and non-psychiatric controls. We examined 2431 participants (mean age 44.3±13.0, 66.1% female), of whom 241 had BD; 1648 had MDD; and 542 were non-psychiatric controls. The MetS was ascertained according to NCEP ATP III criteria. Multivariable analyses were adjusted for age, sex, ethnicity, level of education, smoking status and severity of depressive symptoms, and in the case of BD subjects, also for psychotropic medication use. Subjects with BD had a significantly higher prevalence of MetS when compared to subjects with MDD and non-psychiatric controls (28.4% vs. 20.2% and 16.5%, respectively, pdifferences between BD subjects with controls could partly be ascribed to a higher mean waist circumference (91.0 cm vs. 88.8, respectively, p=0.03). In stratified analysis, the differences in the prevalence of MetS between patients with BD and MDD were found in symptomatic but not in asymptomatic cases. This study confirms a higher prevalence of MetS in patients with BD compared to both MDD patients and controls. Specifically at risk are patients with a higher depression score and abdominal obesity. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Major issues on establishing an emergency plan in nuclear facilities

    International Nuclear Information System (INIS)

    Chen, Zhu-zhou

    1988-03-01

    Several major issues on emergency planning and preparation in nuclear facilities were discussed -- such as the importance of emergency planning and preparation, basic principles of intervention and implementation of emergency plan and emergency training and drills to insure the effectiveness of the emergency plan. It is emphasized that the major key point of emergency planning and response is to avoid the occurrence of serious nonrandom effect. 12 refs., 3 tabs

  11. Safety control and risk management

    International Nuclear Information System (INIS)

    Rasmussen, J.

    1987-01-01

    The acceptable probability of major accidents in nuclear power is very small, and can not be determined from direct empirical evidence. Therefore, control of the level of safety is a complex problem. The difficulty is related to the fact that a variable, 'safety', which is not accessible to direct measurement, is to be tightly controlled. Control, therefore, depends on a systematic, analytical prediction of the target state, i.e., the level of safety, from indirect evidence. From a control theoretic point of view this means that safety is controlled by a system which includes openloop as well as closed loop control paths. The aim of the paper is to take a general systems view on the complex mechanisms involved in the control of safety of industrial installations like nuclear power. From this, the role of probabilistic risk analysis is evaluated and needs for further development discussed. (author)

  12. Fast Change Point Detection for Electricity Market Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Berkeley, UC; Gu, William; Choi, Jaesik; Gu, Ming; Simon, Horst; Wu, Kesheng

    2013-08-25

    Electricity is a vital part of our daily life; therefore it is important to avoid irregularities such as the California Electricity Crisis of 2000 and 2001. In this work, we seek to predict anomalies using advanced machine learning algorithms. These algorithms are effective, but computationally expensive, especially if we plan to apply them on hourly electricity market data covering a number of years. To address this challenge, we significantly accelerate the computation of the Gaussian Process (GP) for time series data. In the context of a Change Point Detection (CPD) algorithm, we reduce its computational complexity from O($n^{5}$) to O($n^{2}$). Our efficient algorithm makes it possible to compute the Change Points using the hourly price data from the California Electricity Crisis. By comparing the detected Change Points with known events, we show that the Change Point Detection algorithm is indeed effective in detecting signals preceding major events.

  13. Three-level grid-connected photovoltaic inverter with maximum power point tracking

    International Nuclear Information System (INIS)

    Tsang, K.M.; Chan, W.L.

    2013-01-01

    Highlight: ► This paper reports a novel 3-level grid connected photovoltaic inverter. ► The inverter features maximum power point tracking and grid current shaping. ► The inverter can be acted as an active filter and a renewable power source. - Abstract: This paper presents a systematic way of designing control scheme for a grid-connected photovoltaic (PV) inverter featuring maximum power point tracking (MPPT) and grid current shaping. Unlike conventional design, only four power switches are required to achieve three output levels and it is not necessary to use any phase-locked-loop circuitry. For the proposed scheme, a simple integral controller has been designed for the tracking of the maximum power point of a PV array based on an improved extremum seeking control method. For the grid-connected inverter, a current loop controller and a voltage loop controller have been designed. The current loop controller is designed to shape the inverter output current while the voltage loop controller can maintain the capacitor voltage at a certain level and provide a reference inverter output current for the PV inverter without affecting the maximum power point of the PV array. Experimental results are included to demonstrate the effectiveness of the tracking and control scheme.

  14. Internet-based cognitive behavior therapy for major depressive disorder: A randomized controlled trial.

    Science.gov (United States)

    Rosso, Isabelle M; Killgore, William D S; Olson, Elizabeth A; Webb, Christian A; Fukunaga, Rena; Auerbach, Randy P; Gogel, Hannah; Buchholz, Jennifer L; Rauch, Scott L

    2017-03-01

    Prior research has shown that the Sadness Program, a technician-assisted Internet-based cognitive behavioral therapy (iCBT) intervention developed in Australia, is effective for treating major depressive disorder (MDD). The current study aimed to expand this work by adapting the protocol for an American population and testing the Sadness Program with an attention control group. In this parallel-group, randomized controlled trial, adult MDD participants (18-45 years) were randomized to a 10-week period of iCBT (n = 37) or monitored attention control (MAC; n = 40). Participants in the iCBT group completed six online therapy lessons, which included access to content summaries and homework assignments. During the 10-week trial, iCBT and MAC participants logged into the web-based system six times to complete self-report symptom scales, and a nonclinician technician contacted participants weekly to provide encouragement and support. The primary outcome was the Hamilton Rating Scale for Depression (HRSD), and the secondary outcomes were the Patient Health Questionnaire-9 and Kessler-10. Intent-to-treat analyses revealed significantly greater reductions in depressive symptoms in iCBT compared with MAC participants, using both the self-report measures and the clinician-rated HRSD (d = -0.80). Importantly, iCBT participants also showed significantly higher rates of clinical response and remission. Exploratory analyses did not support illness severity as a moderator of treatment outcome. The Sadness Program led to significant reductions in depression and distress symptoms. With its potential to be delivered in a scalable, cost-efficient manner, iCBT is a promising strategy to enhance access to effective care. © 2016 Wiley Periodicals, Inc.

  15. Evaluation of maximum power point tracking in hydrokinetic energy conversion systems

    Directory of Open Access Journals (Sweden)

    Jahangir Khan

    2015-11-01

    Full Text Available Maximum power point tracking is a mature control issue for wind, solar and other systems. On the other hand, being a relatively new technology, detailed discussion on power tracking of hydrokinetic energy conversion systems are generally not available. Prior to developing sophisticated control schemes for use in hydrokinetic systems, existing know-how in wind or solar technologies can be explored. In this study, a comparative evaluation of three generic classes of maximum power point scheme is carried out. These schemes are (a tip speed ratio control, (b power signal feedback control, and (c hill climbing search control. In addition, a novel concept for maximum power point tracking: namely, extremum seeking control is introduced. Detailed and validated system models are used in a simulation environment. Potential advantages and drawbacks of each of these schemes are summarised.

  16. Trends in point-of-sale tobacco marketing around college campuses: Opportunities for enhanced tobacco control efforts.

    Science.gov (United States)

    Wagoner, Kimberly G; Sutfin, Erin L; Song, Eunyoung Y; King, Jessica L; Egan, Kathleen L; Reboussin, Beth; Debinski, Beata; Spangler, John; Wolfson, Mark

    2018-04-01

    Colleges have implemented policies to limit tobacco use on-campus; however, the off-campus environment is often overlooked in tobacco control efforts. We assessed availability, marketing, and promotion of cigarettes, snus, and traditional smokeless tobacco (SLT) in a sample of communities surrounding 11 college campuses in North Carolina and Virginia. Between January-March of 2011, 2012 and 2013, 481 tobacco-selling retailers, including convenience stores, pharmacies and supermarkets, located near campuses were assessed. Trained observers completed annual point-of-sale assessments. The percentage of stores selling (81.4% to 58.6%; p < .0001) and advertising snus (80.1% to 53.11%; p < .0001) significantly decreased over time. Convenience stores increased promotions of cigarettes (65.4% to 72.8%; p = 0.04) and SLT (3.1% to 23.3%; p = 0.02). Off-campus environments have abundant tobacco availability and marketing. Colleges should collaborate with state and local tobacco control advocates to address tobacco promotion near campuses to potentially decrease product appeal and access among young adults.

  17. Nova laser alignment control system

    International Nuclear Information System (INIS)

    Van Arsdall, P.J.; Holloway, F.W.; McGuigan, D.L.; Shelton, R.T.

    1984-01-01

    Alignment of the Nova laser requires control of hundreds of optical components in the ten beam paths. Extensive application of computer technology makes daily alignment practical. The control system is designed in a manner which provides both centralized and local manual operator controls integrated with automatic closed loop alignment. Menudriven operator consoles using high resolution color graphics displays overlaid with transport touch panels allow laser personnel to interact efficiently with the computer system. Automatic alignment is accomplished by using image analysis techniques to determine beam references points from video images acquired along the laser chain. A major goal of the design is to contribute substantially to rapid experimental turnaround and consistent alignment results. This paper describes the computer-based control structure and the software methods developed for aligning this large laser system

  18. Comparison between the effects of trigger point mesotherapy versus acupuncture points mesotherapy in the treatment of chronic low back pain: a short term randomized controlled trial.

    Science.gov (United States)

    Di Cesare, Annalisa; Giombini, Arrigo; Di Cesare, Mariachiara; Ripani, Maurizio; Vulpiani, Maria Chiara; Saraceni, Vincenzo Maria

    2011-02-01

    The goal of this study was to compare the effects of trigger point (TRP) mesotherapy and acupuncture (ACP) mesotherapy in the treatment of patients with chronic low back pain. Short term randomized controlled trial. 62 subjects with chronic low back pain were recruited at outpatients Physical Medicine and Rehabilitation Clinic at the University of Rome "La Sapienza" in the period between July 2006 and May 2008. Study subjects were assigned to receive 4 weeks treatments with either trigger point mesotherapy (TRP mesotherapy, n=29) or acupoints mesotherapy (ACP mesotherapy, n=33). Pain intensity with a pain visual analogic scale (VAS) and verbal rating scale (VRS) and pain disability with McGill Pain Questionnaire Short Form (SFMPQ), Roland Morris Disability Questionnaire (RMQ) and Oswestry Low Back Pain Disability Questionaire (ODQ). ACP mesotherapy shows a more effective results in VRS and VAS measures in the follow-up (p(VRS)=mesotherapy group. Our results suggest that the response to ACP mesotherapy may be greater than the response to TRP mesotherapy in the short term follow-up. This technique could be nevertheless a viable option as an adjunct treatment in an overall treatment planning of CLBP. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Evaluation of Plantago major L. seed mucilage as a rate controlling matrix for sustained release of propranolol hydrochloride.

    Science.gov (United States)

    Saeedi, Majid; Morteza-Semnani, Katayoun; Sagheb-Doust, Mehdi

    2013-03-01

    Polysaccharide mucilage derived from the seeds of Plantago major L. (family Plantaginaceae) was investigated for use in matrix formulations containing propranolol hydrochloride. HPMC K4M and tragacanth were used as standards for comparison. The hardness, tensile strength, and friability of tablets increased as the concentration of mucilage increased, indicating good compactibility of mucilage powders. The rate of release of propranolol hydrochloride from P. major mucilage matrices was mainly controlled by the drug/mucilage ratio. Formulations containing P. major mucilage were found to exhibit a release rate comparable to HPMC containing matrices at a lower drug/polymer ratio (drug/HPMC 2:1). These results demonstrated that P. major mucilage is a better release retardant compared to tragacanth at an equivalent content. The results of kinetic analysis showed that in F3 (containing 1:2 drug/mucilage) the highest correlation coefficient was achieved with the zero order model. The swelling and erosion studies revealed that as the proportion of mucilage in tablets was increased, there was a corresponding increase in percent swelling and a decrease in percent erosion of tablets. The DSC and FT-IR studies showed that no formation of complex between the drug and mucilage or changes in crystallinity of the drug had occurred.

  20. Time perception in patients with major depressive disorder during vagus nerve stimulation.

    Science.gov (United States)

    Biermann, T; Kreil, S; Groemer, T W; Maihöfner, C; Richter-Schmiedinger, T; Kornhuber, J; Sperling, W

    2011-07-01

    Affective disorders may affect patients' time perception. Several studies have described time as a function of the frontal lobe. The activating eff ects of vagus nerve stimulation on the frontal lobe might also modulate time perception in patients with major depressive disorder (MDD). Time perception was investigated in 30 patients with MDD and in 7 patients with therapy-resistant MDD. In these 7 patients, a VNS system was implanted and time perception was assessed before and during stimulation. A time estimation task in which patients were asked "How many seconds have passed?" tested time perception at 4 defined time points (34 s, 77 s, 192 s and 230 s). The differences between the estimated and actual durations were calculated and used for subsequent analysis. Patients with MDD and healthy controls estimated the set time points relatively accurately. A general linear model revealed a significant main eff ect of group but not of age or sex. The passing of time was perceived as significantly slower in patients undergoing VNS compared to patients with MDD at all time points (T34: t = − 4.2; df = 35; p differences in time perception with regard to age, sex or polarity of depression (uni- or bipolar). VNS is capable of changing the perception of time. This discovery furthers the basic research on circadian rhythms in patients with psychiatric disorders.