  1. Magnetic resonance study of maghemite-based magnetic fluid

    International Nuclear Information System (INIS)

    Figueiredo, L.C.; Lacava, B.M.; Skeff Neto, K.; Pelegrini, F.; Morais, P.C.

    2008-01-01

    This study reports on the magnetic resonance (MR) data (X-band experiment) of 10.2 nm average diameter maghemite nanoparticle in the temperature range of 100-230 K. Maghemite nanoparticles were suspended as low-pH ionic magnetic fluid containing 2.3x10 17 particles/cm 3 . The temperature dependence of both resonance linewidth and resonance field of the zero-field-cooled sample as well as the resonance field of the field-cooled sample (angular variation experiment) was analyzed using well-established methodology. Information regarding particle size, particle clusterization and surface magnetic anisotropy were obtained from the analysis of the MR data. The number of magnetic sites per particle from the MR data is in excellent agreement with the number provided by the transmission electron microscopy (TEM) data. The demagnetizing field value obtained from the MR data indicates cluster of particles containing on average 1.42 particles. The MR angular variation data suggest that magnetoelastic effect accounts for the non-linearity observed for the surface component of the magnetic anisotropy

  2. Magnetic resonance imaging of cerebrospinal fluid flow in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Heroux, R. [Children' s Hospital of Eastern Ontario, Magnetic Resonance Imaging Dept., Ottawa, Ontario (Canada)

    2000-06-30

    Magnetic Resonance Imaging of flowing protons in cerebrospinal fluid is useful for demonstrating areas of obstruction or stenosis of the ventricular system causing hydrocephalus. This is used in pediatric patients to assess the circulation of the cerebrospinal fluid. This article discusses two studies. In the first, the cerebrospinal fluid flow study helped the neurosurgeon assess the patency after a third ventriculocisternostomy. The second study evaluated the cerebrospinal fluid flowing through the foramen magnum in a patient with cerebellar tonsilar descent (Chiari malformation) and a syringomyelia. Different techniques to evaluate the flow studies are also discussed. (author)

  3. Study of biological fluids by nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Kriat, M.; Vion-Dury, J.; Confort-Gouny, S.; Sciaky, M.; Cozzone, P.J.

    1991-01-01

    The use of nuclear magnetic resonance (NMR) spectroscopy in the study of biofluids is rapidly developing and might soon constitute a new major medical application of this technique which benefits from technological and methodological progress such as higher magnetic fields, new probe design, solvent suppression sequences and advanced data processing routines. In this overview, the clinical and pharmacological impact of this new approach is examined, with emphasis on the NMR spectroscopy of plasma, cerebrospinal fluid and urine. Applications to pharmacokinetics and toxicology are illustrated. Interestingly, a number of biochemical components of fluids which are not usually assayed by conventional biochemical methods are readily detected by NMR spectroscopy which is clearly a new competitive entrant among the techniques used in clinical biology. Its ease-of-use, cost effectiveness and high informational content might turn it into a major diagnostic tool in the years to come [fr

  4. Some applications of magnetic resonance imaging in fluid mechanics: Complex flows and complex fluids

    NARCIS (Netherlands)

    Bonn, Daniel; Rodts, Stephane; Groenink, Maarten; Rafai, Salima; Shahidzadeh-Bonn, Noushine; Coussot, Philippe

    2008-01-01

    The review deals with applications of magnetic resonance imaging (MRI) techniques to study flow. We first briefly discuss the principles of flow measurement by MRI and give examples of some applications, such as multiphase flows, the MRI rheology of complex fluid flows, and blood flows in the human

  5. Thermal and particle size distribution effects on the ferromagnetic resonance in magnetic fluids

    International Nuclear Information System (INIS)

    Marin, C.N.

    2006-01-01

    Thermal and particle size distribution effects on the ferromagnetic resonance of magnetic fluids were theoretically investigated, assuming negligible interparticle interactions and neglecting the viscosity of the carrier liquid. The model is based on the usual approach for the ferromagnetic resonance description of single-domain magnetic particle systems, which was amended in order to take into account the finite particle size effect, the particle size distribution and the orientation mobility of the particles within the magnetic fluid. Under these circumstances the shape of the resonance line, the resonance field and the line width are found to be strongly affected by the temperature and by the particle size distribution of magnetic fluids

  6. Differentiating benign from malignant bone tumors using fluid-fluid level features on magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Hong; Cui, Jian Ling; Cui, Sheng Jie; Sun, Ying Cal; Cui, Feng Zhen [Dept. of Radiology, The Third Hospital of Hebei Medical University, Hebei Province Biomechanical Key Laborary of Orthopedics, Shijiazhuang, Hebei (China)

    2014-12-15

    To analyze different fluid-fluid level features between benign and malignant bone tumors on magnetic resonance imaging (MRI). This study was approved by the hospital ethics committee. We retrospectively analyzed 47 patients diagnosed with benign (n = 29) or malignant (n = 18) bone tumors demonstrated by biopsy/surgical resection and who showed the intratumoral fluid-fluid level on pre-surgical MRI. The maximum length of the largest fluid-fluid level and the ratio of the maximum length of the largest fluid-fluid level to the maximum length of a bone tumor in the sagittal plane were investigated for use in distinguishing benign from malignant tumors using the Mann-Whitney U-test and a receiver operating characteristic (ROC) analysis. Fluid-fluid level was categorized by quantity (multiple vs. single fluid-fluid level) and by T1-weighted image signal pattern (high/low, low/high, and undifferentiated), and the findings were compared between the benign and malignant groups using the chi2 test. The ratio of the maximum length of the largest fluid-fluid level to the maximum length of bone tumors in the sagittal plane that allowed statistically significant differentiation between benign and malignant bone tumors had an area under the ROC curve of 0.758 (95% confidence interval, 0.616-0.899). A cutoff value of 41.5% (higher value suggests a benign tumor) had sensitivity of 73% and specificity of 83%. The ratio of the maximum length of the largest fluid-fluid level to the maximum length of a bone tumor in the sagittal plane may be useful to differentiate benign from malignant bone tumors.

  7. Differentiating benign from malignant bone tumors using fluid-fluid level features on magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yu, Hong; Cui, Jian Ling; Cui, Sheng Jie; Sun, Ying Cal; Cui, Feng Zhen

    2014-01-01

    To analyze different fluid-fluid level features between benign and malignant bone tumors on magnetic resonance imaging (MRI). This study was approved by the hospital ethics committee. We retrospectively analyzed 47 patients diagnosed with benign (n = 29) or malignant (n = 18) bone tumors demonstrated by biopsy/surgical resection and who showed the intratumoral fluid-fluid level on pre-surgical MRI. The maximum length of the largest fluid-fluid level and the ratio of the maximum length of the largest fluid-fluid level to the maximum length of a bone tumor in the sagittal plane were investigated for use in distinguishing benign from malignant tumors using the Mann-Whitney U-test and a receiver operating characteristic (ROC) analysis. Fluid-fluid level was categorized by quantity (multiple vs. single fluid-fluid level) and by T1-weighted image signal pattern (high/low, low/high, and undifferentiated), and the findings were compared between the benign and malignant groups using the chi2 test. The ratio of the maximum length of the largest fluid-fluid level to the maximum length of bone tumors in the sagittal plane that allowed statistically significant differentiation between benign and malignant bone tumors had an area under the ROC curve of 0.758 (95% confidence interval, 0.616-0.899). A cutoff value of 41.5% (higher value suggests a benign tumor) had sensitivity of 73% and specificity of 83%. The ratio of the maximum length of the largest fluid-fluid level to the maximum length of a bone tumor in the sagittal plane may be useful to differentiate benign from malignant bone tumors.

  8. Magnetic resonance of field-frozen and zero-field-frozen magnetic fluids

    International Nuclear Information System (INIS)

    Pereira, A.R.; Pelegrini, F.; Neto, K. Skeff; Buske, N.; Morais, P.C.

    2004-01-01

    In this study magnetic resonance was used to investigate magnetic fluid samples frozen under zero and non-zero (15 kG) external fields. The magnetite-based sample containing 2x10 17 particle/cm 3 was investigated from 100 to 400 K. Analysis of the temperature dependence of the resonance field revealed bigger magnetic structures in the frozen state than in the liquid phase. Also, differences in the mesoscopic organization in the frozen state may explain the data obtained from samples frozen under zero and non-zero fields

  9. Static fluid magnetic resonance urography in evaluation of ureteral ...

    African Journals Online (AJOL)

    Introduction: Ectopic ureters are often very difficult to diagnose with conventional imaging modalities especially in children. Magnetic resonance urography (MRU) has been recently investigated as a problem-solving tool for the evaluation of various congenital urogenital anomalies with favorable results. Aim of the work: To ...

  10. The effect of colloidal stabilization upon ferrimagnetic resonance in magnetic fluids in the presence of a polarizing magnetic field

    CERN Document Server

    Fannin, P C; Socoliuc, V; Istratuca, G M; Giannitsis, A T

    2003-01-01

    The complex magnetic susceptibility of two magnetic fluids, with different degrees of colloidal stabilization, has been measured over the frequency range 100 MHz to 6 GHz. The colloidal stabilization of the magnetic fluids has been investigated using magneto-optical measurements. Based on complex magnetic susceptibility measurements, chi(omega) chi'(omega)-i chi''(omega), the dependence of the maximum absorption frequency at resonance, f sub m sub a sub x , and of line width, DELTA f, on an external magnetic polarizing field, H, over the range 0-1.45 kOe, has been examined for both magnetic fluids. The experimental results have been interpreted in terms of magnetic interparticle interactions and particle agglomeration.

  11. Preliminary analysis of proton magnetic resonance 1D spectra of cerebrospinal fluid and brain cancer extracts

    International Nuclear Information System (INIS)

    Toczylowska, B.; Jozwik, A.; Kierul, K.; Matysiak, Z.; Sidor, M.; Wojcik, J.

    1999-01-01

    In series of cerebrospinal fluid samples from 25 patients proton spectra of magnetic resonance were measured. The spectra were measured also for series of brain tumor tissue extracts received from another 25 patients. This paper presents an attempt to apply statistical methods of image recognition for spectra analysis of the two measured series

  12. Rheo-NMR: nuclear magnetic resonance and the rheology of complex fluids

    International Nuclear Information System (INIS)

    Callaghan, Paul T.

    1999-01-01

    The application of nuclear magnetic resonance methods to the study of complex fluids under shearing and extensional flows is reviewed. Both NMR velocimetry and spectroscopy approaches are discussed while specific systems studied include polymer melts, rigid rod and random coil polymers in solution, lyotropic and thermotropic liquid crystals and liquid crystalline polymers, and wormlike micelles. Reference is made to food systems. (author)

  13. A Noninvasive Method to Study Regulation of Extracellular Fluid Volume in Rats Using Nuclear Magnetic Resonance

    Science.gov (United States)

    Time-domain nuclear magnetic resonance (TD-NMR)-based measurement of body composition of rodents is an effective method to quickly and repeatedly measure proportions of fat, lean, and fluid without anesthesia. TD-NMR provides a measure of free water in a living animal, termed % f...

  14. Pulsed-field gradient nuclear magnetic resonance study of transport properties of fluid catalytic cracking catalysts

    Czech Academy of Sciences Publication Activity Database

    Kortunov, P.; Vasenkov, S.; Kärger, J.; Fé Elía, M.; Perez, M.; Stöcker, M.; Papadopoulos, G. K.; Theodorou, D.; Drescher, B.; McElhiney, G.; Bernauer, B.; Krystl, V.; Kočiřík, Milan; Zikánová, Arlette; Jirglová, Hana; Berger, C.; Gläser, R.; Weitkamp, J.; Hansen, E. W.

    2005-01-01

    Roč. 23, č. 2 (2005), s. 233-237 ISSN 0730-725X Grant - others:TROCAT project - European Community(DE) G5RD-CT-2001-00520 Institutional research plan: CEZ:AV0Z40400503 Keywords : pulsed-field gradient * nuclear magnetic resonance * fluid catalytic cracking catalyst Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.361, year: 2005

  15. Shale characteristics impact on Nuclear Magnetic Resonance (NMR fluid typing methods and correlations

    Directory of Open Access Journals (Sweden)

    Mohamed Mehana

    2016-06-01

    Full Text Available The development of shale reservoirs has brought a paradigm shift in the worldwide energy equation. This entails developing robust techniques to properly evaluate and unlock the potential of those reservoirs. The application of Nuclear Magnetic Resonance techniques in fluid typing and properties estimation is well-developed in conventional reservoirs. However, Shale reservoirs characteristics like pore size, organic matter, clay content, wettability, adsorption, and mineralogy would limit the applicability of the used interpretation methods and correlation. Some of these limitations include the inapplicability of the controlling equations that were derived assuming fast relaxation regime, the overlap of different fluids peaks and the lack of robust correlation to estimate fluid properties in shale. This study presents a state-of-the-art review of the main contributions presented on fluid typing methods and correlations in both experimental and theoretical side. The study involves Dual Tw, Dual Te, and doping agent's application, T1-T2, D-T2 and T2sec vs. T1/T2 methods. In addition, fluid properties estimation such as density, viscosity and the gas-oil ratio is discussed. This study investigates the applicability of these methods along with a study of the current fluid properties correlations and their limitations. Moreover, it recommends the appropriate method and correlation which are capable of tackling shale heterogeneity.

  16. Magnetic resonance imaging biomarkers of gastrointestinal motor function and fluid distribution

    Institute of Scientific and Technical Information of China (English)

    Asseel; Khalaf; Caroline; L; Hoad; Robin; C; Spiller; Penny; A; Gowland; Gordon; W; Moran; Luca; Marciani

    2015-01-01

    Magnetic resonance imaging(MRI) is a well established technique that has revolutionized diagnostic radiology. Until recently, the impact that MRI has had in the assessment of gastrointestinal motor function and bowel fluid distribution in health and in disease has been more limited, despite the novel insights that MRI can provide along the entire gastrointestinal tract. MRI biomarkers include intestinal motility indices, small bowel water content and whole gut transit time. The present review discusses new developments and applications of MRI in the upper gastrointestinal tract, the small bowel and the colon reported in the literature in the last 5 years.

  17. Anisotropic multi-scale fluid registration: evaluation in magnetic resonance breast imaging

    International Nuclear Information System (INIS)

    Crum, W R; Tanner, C; Hawkes, D J

    2005-01-01

    Registration using models of compressible viscous fluids has not found the general application of some other techniques (e.g., free-form-deformation (FFD)) despite its ability to model large diffeomorphic deformations. We report on a multi-resolution fluid registration algorithm which improves on previous work by (a) directly solving the Navier-Stokes equation at the resolution of the images (b) accommodating image sampling anisotropy using semi-coarsening and implicit smoothing in a full multi-grid (FMG) solver and (c) exploiting the inherent multi-resolution nature of FMG to implement a multi-scale approach. Evaluation is on five magnetic resonance (MR) breast images subject to six biomechanical deformation fields over 11 multi-resolution schemes. Quantitative assessment is by tissue overlaps and target registration errors and by registering using the known correspondences rather than image features to validate the fluid model. Context is given by comparison with a validated FFD algorithm and by application to images of volunteers subjected to large applied deformation. The results show that fluid registration of 3D breast MR images to sub-voxel accuracy is possible in minutes on a 1.6 GHz Linux-based Athlon processor with coarse solutions obtainable in a few tens of seconds. Accuracy and computation time are comparable to FFD techniques validated for this application

  18. Magnetic resonance annual 1986

    International Nuclear Information System (INIS)

    Kressel, H.Y.

    1986-01-01

    This book contains papers written on magnetic resonance during 1986. Topics include: musculosketetal magnetic resonance imaging; imaging of the spine; magnetic resonance chemical shift imaging; magnetic resonance imaging in the central nervous system; comparison to computed tomography; high resolution magnetic resonance imaging using surface coils; magnetic resonance imaging of the chest; magnetic resonance imaging of the breast; magnetic resonance imaging of the liver; magnetic resonance spectroscopy of neoplasms; blood flow effects in magnetic resonance imaging; and current and potential applications of clinical sodium magnetic resonance imaging

  19. Magnetic resonance of phase transitions

    CERN Document Server

    Owens, Frank J; Farach, Horacio A

    1979-01-01

    Magnetic Resonance of Phase Transitions shows how the effects of phase transitions are manifested in the magnetic resonance data. The book discusses the basic concepts of structural phase and magnetic resonance; various types of magnetic resonances and their underlying principles; and the radiofrequency methods of nuclear magnetic resonance. The text also describes quadrupole methods; the microwave technique of electron spin resonance; and the Mössbauer effect. Phase transitions in various systems such as fluids, liquid crystals, and crystals, including paramagnets and ferroelectrics, are also

  20. Diffusion-Weighted Magnetic Resonance Imaging of Cerebrospinal Fluid in Patients with and without Communicating Hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Nasel, C.; Gentzsch, S.; Heimberger, K. [Cerebrovascular Imaging Workgroup of the Div. of Neuroradiology, Dept. of Radiology, Medical Univ. Vienna, Vienna (Austria)

    2007-09-15

    Background: Recent concepts about cerebrospinal fluid (CSF) circulation in communicating hydrocephalus (CoHy), which is also termed 'restricted arterial pulsation hydrocephalus,' suggest reduced arterial pulsations of subarachnoid vessels with a smaller amount of CSF shifted in subarachnoid spaces during the early systole. The postulated restriction of subarachnoid arterial pulsations in CoHy should induce a smaller motion artifact and reduced local stream effects in CSF in magnetic resonance (MR) diffusion-weighted imaging (DWI). Purpose: To investigate the maximum diffusivity in CSF in patients with and without CoHy using DWI. Material and Methods: 12 patients without CSF circulation disturbances and six cases with proven CoHy were assessed. Diffusion was measured in six non collinear directions without triggering the arterial pulse wave (scan time 6:45 min, voxel size 2x2x2 mm). Due to expected artifacts, the calculated maximum diffusivity was called apparent diffusivity. Regional high and low apparent diffusivity was assessed in CSF spaces on newly created 3D CSF motion maps. Results: Patients with regular CSF circulation exhibited high apparent diffusivity in CSF in basal subarachnoid spaces, whereas apparent diffusivity was low there in patients with CoHy. Conclusion: DWI opens a feasible approach to study CSF motion in the neurocranium. Restricted arterial pulsations seem to be involved in CoHy.

  1. Diffusion-Weighted Magnetic Resonance Imaging of Cerebrospinal Fluid in Patients with and without Communicating Hydrocephalus

    International Nuclear Information System (INIS)

    Nasel, C.; Gentzsch, S.; Heimberger, K.

    2007-01-01

    Background: Recent concepts about cerebrospinal fluid (CSF) circulation in communicating hydrocephalus (CoHy), which is also termed 'restricted arterial pulsation hydrocephalus,' suggest reduced arterial pulsations of subarachnoid vessels with a smaller amount of CSF shifted in subarachnoid spaces during the early systole. The postulated restriction of subarachnoid arterial pulsations in CoHy should induce a smaller motion artifact and reduced local stream effects in CSF in magnetic resonance (MR) diffusion-weighted imaging (DWI). Purpose: To investigate the maximum diffusivity in CSF in patients with and without CoHy using DWI. Material and Methods: 12 patients without CSF circulation disturbances and six cases with proven CoHy were assessed. Diffusion was measured in six non collinear directions without triggering the arterial pulse wave (scan time 6:45 min, voxel size 2x2x2 mm). Due to expected artifacts, the calculated maximum diffusivity was called apparent diffusivity. Regional high and low apparent diffusivity was assessed in CSF spaces on newly created 3D CSF motion maps. Results: Patients with regular CSF circulation exhibited high apparent diffusivity in CSF in basal subarachnoid spaces, whereas apparent diffusivity was low there in patients with CoHy. Conclusion: DWI opens a feasible approach to study CSF motion in the neurocranium. Restricted arterial pulsations seem to be involved in CoHy

  2. Rheo-NMR - how nuclear magnetic resonance is providing new insight regarding complex fluid rheology

    International Nuclear Information System (INIS)

    Callaghan, P.T.

    2000-01-01

    Over the past five decades, NMR has revolutionised chemistry, and has found widespread application in condensed matter physics, in molecular biology, in medicine and in food technology. Most recently NMR has made a significant impact in chemical engineering, where it is being extensively used for the non-invasive study of dispersion and flow in porous media. One of the most recent applications of NMR in materials science concerns its use in the study of the mechanical properties of complex fluids. This particular aspect of NMR has been extensively developed in research carried out at Massey University in New Zealand. In this short article, some of the ideas behind this work and the applications which have resulted, will be described. These examples provide a glimpse of possible applications of Nuclear Magnetic Resonance to the study of complex fluid rheology. While this is a very new field of research in which only a handful of groups presently participate, the potential exists for a substantial increase in Rheo-NMR research activity. Systems studied to date include polymer melts and semi-dilute solutions, thermotropic and lyotropic liquid crystals and liquid crystalline polymers, micellar solutions, food materials and colloidal suspensions. Rheo-NMR suffers in a number of respects by comparison with optical methods. It is expensive, it is difficult to use, it suffers from poor signal-to-noise ratios and the effective interpretation of spectra often depends on familiarity with the nuclear spin Hamiltonian and the associated effects of spin dynamics. Nonetheless NMR offers some unique advantages, including the ability to work with opaque materials, the ability to combine velocimetry with localised spectroscopy, and the ability to access a wide range of molecular properties relating to organisation, orientation and dynamics. Rheo-NMR has been able to provide a direct window on a variety of behaviours, including slip, shear-thinning, shear banding, yield stress

  3. Magnetic resonance annual, 1988

    International Nuclear Information System (INIS)

    Kressel, H.Y.

    1987-01-01

    This book features reviews of high-resolution MRI of the knee, MRI of the normal and ischmeic hip, MRI of the heart, and temporomandibular joint imaging, as well as thorough discussion on artifacts in magnetic resonance imaging. Contributors consider the clinical applications of gadolinium-DTPA in magnetic resonance imaging and the clinical use of partial saturation and saturation recovery sequences. Timely reports assess the current status of rapid MRI and describe a new rapid gated cine MRI technique. Also included is an analysis of cerebrospinal fluid flow effects during MRI of the central nervous system

  4. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Magnetic Resonance Imaging (MRI) is a medical imaging procedure for ...

  5. Cardiovascular fluid dynamics. Methods for flow and pressure field analysis from magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ebbers, T.

    2001-01-01

    Cardiovascular blood flow is highly complex and incompletely understood. Blood flow patterns are expected to influence the opening and closing of normal and prosthetic heart valves, the efficiency of cardiac filling and ejection, and the resistance to thrombus formation within the heart. Conventional diagnostic techniques are poorly suited to the study of the three-dimensional (3D) blood flow patterns in the heart chambers and large vessels. Noninvasive methods have also been inadequate in studying intracardiac pressure differences, which are the driving force of flow and are critical in the evaluation of many cardiovascular abnormalities. This thesis focuses on the development of non-invasive methods for analysis of 3D cardiovascular blood flow. Simultaneous study of cardiovascular fluid dynamics allowed knowledge exchange across the two disciplines, facilitating the development process and broadening the applicability of the methods. A time-resolved 3D phase-contrast Magnetic Resonance Imaging (MRI) technique was used to acquire the velocity vector field in a 3D volume encompassing the entire heart or a large vessel. Cardiovascular blood flow patterns were visualized by use of particle traces, which revealed, for instance, vortical flow patterns in the left atrium. By applying the Navier-Stokes equation along a user-defined line in the 3D velocity vector field, the relative pressure could be obtained as an excellent supplement to the flow pattern visualization. Using a delineation of the blood pool, the time-varying 3D relative pressure field in the human left ventricle was obtained from the velocity field by use of the pressure Poisson equation. A delineation of the heart muscle, a task that is almost impossible to perform on 3D MRI either automatically or manually, was also achieved by usage of particle traces. This segmentation allows automatic calculation of the 3D relative pressure field, as well as calculation of well-established parameters such as

  6. Cardiovascular fluid dynamics. Methods for flow and pressure field analysis from magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ebbers, T

    2001-05-01

    Cardiovascular blood flow is highly complex and incompletely understood. Blood flow patterns are expected to influence the opening and closing of normal and prosthetic heart valves, the efficiency of cardiac filling and ejection, and the resistance to thrombus formation within the heart. Conventional diagnostic techniques are poorly suited to the study of the three-dimensional (3D) blood flow patterns in the heart chambers and large vessels. Noninvasive methods have also been inadequate in studying intracardiac pressure differences, which are the driving force of flow and are critical in the evaluation of many cardiovascular abnormalities. This thesis focuses on the development of non-invasive methods for analysis of 3D cardiovascular blood flow. Simultaneous study of cardiovascular fluid dynamics allowed knowledge exchange across the two disciplines, facilitating the development process and broadening the applicability of the methods. A time-resolved 3D phase-contrast Magnetic Resonance Imaging (MRI) technique was used to acquire the velocity vector field in a 3D volume encompassing the entire heart or a large vessel. Cardiovascular blood flow patterns were visualized by use of particle traces, which revealed, for instance, vortical flow patterns in the left atrium. By applying the Navier-Stokes equation along a user-defined line in the 3D velocity vector field, the relative pressure could be obtained as an excellent supplement to the flow pattern visualization. Using a delineation of the blood pool, the time-varying 3D relative pressure field in the human left ventricle was obtained from the velocity field by use of the pressure Poisson equation. A delineation of the heart muscle, a task that is almost impossible to perform on 3D MRI either automatically or manually, was also achieved by usage of particle traces. This segmentation allows automatic calculation of the 3D relative pressure field, as well as calculation of well-established parameters such as

  7. Use of magnetic resonance to study biodistribution of dextran-coated magnetic fluid intravenously administered in mice

    International Nuclear Information System (INIS)

    Lacava, L.M.; Lacava, Z.G.M.; Azevedo, R.B.; Chaves, S.B.; Garcia, V.A.P.; Silva, O.; Pelegrini, F.; Buske, N.; Gansau, C.; Da Silva, M.F.; Morais, P.C.

    2002-01-01

    Magnetic resonance was used to investigate the kinetic disposition and the subsequent biodistribution of dextran-coated magnetite nanoparticles (9.4 nm core diameter) after intravenous injection of a bolus dose in female Swiss mice. The X-band spectra show a broad single-line at g∼2, typical of nanomagnetic particles suspended in a non-magnetic matrix. In the first 90 min the time-decay of the nanoparticle concentration in the bloodstream follows the one-exponential (one-compartment) model with a half-life of 6.9 min. With respect to blood the clearance (90 μl/min) and the volume of distribution (900 μl) were obtained from the magnetic resonance data. Magnetite nanoparticles were found 90 min after administration in liver and spleen with a typical absorption half-life of 14 min

  8. Importance of contrast-enhanced fluid-attenuated inversion reconvery magnetic resonance imaging in various intracranial pathologic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Kyoung; Lee, Eun Ja; Kim, Sung Won; Lee, Yong Seok [Dept. of Radiology, Dongguk University Ilsan Hospital, Goyang(Korea, Republic of)

    2016-02-15

    Intracranial lesions may show contrast enhancement through various mechanisms that are closely associated with the disease process. The preferred magnetic resonance sequence in contrast imaging is T1-weighted imaging (T1WI) at most institutions. However, lesion enhancement is occasionally inconspicuous on T1WI. Although fluid-attenuated inversion recovery (FLAIR) sequences are commonly considered as T2-weighted imaging with dark cerebrospinal fluid, they also show mild T1-weighted contrast, which is responsible for the contrast enhancement. For several years, FLAIR imaging has been successfully incorporated as a routine sequence at our institution for contrast-enhanced (CE) brain imaging in detecting various intracranial diseases. In this pictorial essay, we describe and illustrate the diagnostic importance of CE-FLAIR imaging in various intracranial pathologic conditions.

  9. In vivo (1)H magnetic resonance spectroscopy of amniotic fluid and fetal lung at 1.5 T: technical challenges.

    Science.gov (United States)

    Kim, Dong-Hyun; Vahidi, Kiarash; Caughey, Aaron B; Coakley, Fergus V; Vigneron, Daniel B; Kurhanewicz, John; Mow, Ben; Joe, Bonnie N

    2008-10-01

    To identify the major technical challenges associated with in utero single-voxel proton spectroscopy of amniotic fluid and fetal lung and to evaluate the feasibility of performing in utero fetal spectroscopy for fetal lung maturity testing. Fetal magnetic resonance (MR) spectroscopy of amniotic fluid and fetal lung were performed at 1.5 T in 8 near-term pregnant women. Presence/absence of lactate and choline peaks was tabulated. Ex vivo spectra were obtained from amniotic fluid samples to investigate and refine sequence parameters. Spectroscopy failed in 3 of 8 cases due to maternal discomfort (n = 1) or fetal gastroschisis (n = 2). Both fetal motion and low signal-to-noise ratio were limiting factors for the remaining 5 clinical in vivo studies at 1.5 T. Ex vivo and in vivo studies suggested feasibility for detecting lactate from amniotic fluid within a reasonable clinical scan time (4-5 minutes). Lactate was detected in 3 of 5 patients. Choline detection was limited and was detected in 1 patient. Minor motion effects can be overcome but continuous fetal motion is problematic. Lactate detection seems clinically feasible, but choline detection requires additional technical development and, potentially, further imaging at a higher field strength because of the low signal-to-noise ratio at 1.5 T. (c) 2008 Wiley-Liss, Inc.

  10. Advances in magnetic resonance 2

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 2, features a mixture of experimental and theoretical contributions. The book contains four chapters and begins with an ambitious and general treatment of the problem of signal-to-noise ratio in magnetic resonance. This is followed by separate chapters on the interpretation of nuclear relaxation in fluids, with special reference to hydrogen; and various aspects of molecular theory of importance in NMR.

  11. Cerebrospinal fluid metabolic profiles in multiple sclerosis and degenerative dementias obtained by high resolution proton magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Vion-Dury, J.; Confort-Gouny, S.; Maillet, S.; Cozzone, P.J.; Nicoli, F.; Gastaut, J.L.

    1996-01-01

    We have analyzed the cerebrospinal fluid (CSF) of 19 patients with multiple sclerosis (MS), 12 patients with degenerative dementia and 17 control patients using in vitro high resolution proton magnetic resonance spectroscopy (MRS) at 400 MHz. The CSF metabolic profile is slightly modified in MS patients (increased lactate and fructose concentrations, decreased creatinine and phenylalanine concentrations) and is not correlated with the intensity of the intrathecal inflammation. Proton MRS of CSF does not differentiate relapsing-remitting MS and primary progressive MS. We have not detected any specific abnormal resonance in native or lyophilized CSF. The CSF metabolic profile of demented patients is much more altered (increased concentration of lactate, pyruvate, alanine, lysine, valine, leucine-isoleucine, tyrosine, glutamine) and is in agreement with a brain oxidative metabolism impairment as already described in Alzheimer's disease. Unassigned abnormal but non specific or constant resonances have been detected on MR spectra of demented patients. CSF inositol concentration is also increased in the CSF of patients with Alzheimer's disease. In vitro high resolution proton MRS of the CSF constitutes a new and original way to explore CSF for the differential and/or early diagnosis of dementias, as a complement to in vivo proton cerebral MRS. (authors). 22 refs., 4 figs., 2 tabs

  12. Cerebrospinal fluid metabolic profiles in multiple sclerosis and degenerative dementias obtained by high resolution proton magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Vion-Dury, J.; Confort-Gouny, S.; Maillet, S.; Cozzone, P.J. [Centre Hospitalier Universitaire de la Timone, 13 - Marseille (France); Nicoli, F. [Centre Hospitalier Universitaire de la Timone, 13 - Marseille (France)]|[Hopital Sainte-Marguerite, 13 - Marseille (France); Gastaut, J.L. [Hopital Sainte-Marguerite, 13 - Marseille (France)

    1996-07-01

    We have analyzed the cerebrospinal fluid (CSF) of 19 patients with multiple sclerosis (MS), 12 patients with degenerative dementia and 17 control patients using in vitro high resolution proton magnetic resonance spectroscopy (MRS) at 400 MHz. The CSF metabolic profile is slightly modified in MS patients (increased lactate and fructose concentrations, decreased creatinine and phenylalanine concentrations) and is not correlated with the intensity of the intrathecal inflammation. Proton MRS of CSF does not differentiate relapsing-remitting MS and primary progressive MS. We have not detected any specific abnormal resonance in native or lyophilized CSF. The CSF metabolic profile of demented patients is much more altered (increased concentration of lactate, pyruvate, alanine, lysine, valine, leucine-isoleucine, tyrosine, glutamine) and is in agreement with a brain oxidative metabolism impairment as already described in Alzheimer`s disease. Unassigned abnormal but non specific or constant resonances have been detected on MR spectra of demented patients. CSF inositol concentration is also increased in the CSF of patients with Alzheimer`s disease. In vitro high resolution proton MRS of the CSF constitutes a new and original way to explore CSF for the differential and/or early diagnosis of dementias, as a complement to in vivo proton cerebral MRS. (authors). 22 refs., 4 figs., 2 tabs.

  13. Pediatric magnetic resonance imaging

    International Nuclear Information System (INIS)

    Cohen, M.D.

    1986-01-01

    This book defines the current clinical potential of magnetic resonance imaging and focuses on direct clinical work with pediatric patients. A section dealing with the physics of magnetic resonance imaging provides an introduction to enable clinicians to utilize the machine and interpret the images. Magnetic resonance imaging is presented as an appropriate imaging modality for pediatric patients utilizing no radiation

  14. Windowed direct exponential curve resolution quantification of nuclear magnetic resonance spectroscopy with applications to amniotic fluid metabonomics

    International Nuclear Information System (INIS)

    Botros, L.L.

    2007-01-01

    This thesis presents a quantitative protocol of proton nuclear magnetic resonance ( 1 H NMR) that allows the determination of human amniotic fluid metabolite concentrations, which are then used in a metabonomic study to establish patient health during gestation. 1 H NMR free inductive decays (FIDs) of 258 human amniotic fluid samples from a 500MHz spectrometer are acquired. Quantitative analyses methods in both the frequency- and time-domain are carried out and compared. Frequency-domain analysis is accomplished by integration of the metabolite peaks before and after the inclusion of a known standard addition of alanine. Time-domain analysis is accomplished by the direct exponential curve resolution algorithm (DECRA). Both techniques are assessed by applications to calibration biological solutions and a simulated data set. The DECRA method proves to be a more accurate and precise route for quantitative analysis, and is included in the developed protocol. Well-defined peaks of various components are visible in the frequency-domain 1 H NMR spectra, including lactate, alanine, acetate, citrate, choline, glycine, and glucose. All are quantified with the proposed protocol. Statistical t-test and notched box and whisker plots are used to compare means of metabolite concentrations for diabetic and normal patients. Glucose, glycine, and choline are all found to correlate with gestational diabetes mellitus early in gestation. With further development, time-domain quantitative 1 H NMR has potential to become a robust diagnostic tool for gestational health. (author)

  15. Windowed direct exponential curve resolution quantification of nuclear magnetic resonance spectroscopy with applications to amniotic fluid metabonomics

    Energy Technology Data Exchange (ETDEWEB)

    Botros, L.L

    2007-07-01

    This thesis presents a quantitative protocol of proton nuclear magnetic resonance ({sup 1}H NMR) that allows the determination of human amniotic fluid metabolite concentrations, which are then used in a metabonomic study to establish patient health during gestation. {sup 1}H NMR free inductive decays (FIDs) of 258 human amniotic fluid samples from a 500MHz spectrometer are acquired. Quantitative analyses methods in both the frequency- and time-domain are carried out and compared. Frequency-domain analysis is accomplished by integration of the metabolite peaks before and after the inclusion of a known standard addition of alanine. Time-domain analysis is accomplished by the direct exponential curve resolution algorithm (DECRA). Both techniques are assessed by applications to calibration biological solutions and a simulated data set. The DECRA method proves to be a more accurate and precise route for quantitative analysis, and is included in the developed protocol. Well-defined peaks of various components are visible in the frequency-domain {sup 1}H NMR spectra, including lactate, alanine, acetate, citrate, choline, glycine, and glucose. All are quantified with the proposed protocol. Statistical t-test and notched box and whisker plots are used to compare means of metabolite concentrations for diabetic and normal patients. Glucose, glycine, and choline are all found to correlate with gestational diabetes mellitus early in gestation. With further development, time-domain quantitative {sup 1}H NMR has potential to become a robust diagnostic tool for gestational health. (author)

  16. A noninvasive method to study regulation of extracellular fluid volume in rats using nuclear magnetic resonance

    Data.gov (United States)

    U.S. Environmental Protection Agency — NMR fluid measurements of commonly used rat strains when subjected to SQ normotonic or hypertonic salines, as well as physiologic comparisons to sedentary and...

  17. Magnetic resonance imaging apparatus

    International Nuclear Information System (INIS)

    Ehnholm, G.J.

    1991-01-01

    This patent describes an electron spin resonance enhanced magnetic resonance (MR) imaging (ESREMRI) apparatus able to generate a primary magnetic field during periods of nuclear spin transition excitation and magnetic resonance signal detection. This allows the generation of ESREMRI images of a subject. A primary magnetic field of a second and higher value generated during periods of nuclear spin transition excitation and magnetic resonance signal detection can be used to generate conventional MR images of a subject. The ESREMRI and native MR images so generated may be combined, (or superimposed). (author)

  18. Metabolite Profiling of Human Amniotic Fluid by Hyphenated Nuclear Magnetic Resonance Spectroscopy

    OpenAIRE

    Graça, Gonçalo; Duarte, Iola F.; Goodfellow, Brian J.; Carreira, Isabel M.; Couceiro, Ana Bela; Domingues, Maria do Rosário; Spraul, Manfred; Tseng, Li-Hong; Gil, Ana M.

    2008-01-01

    The metabolic profiling of human amniotic fluid (HAF) is of potential interest for the diagnosis of disorders in the mother or the fetus. In order to build a comprehensive metabolite database for HAF, hyphenated NMR has been used, for the first time, for systematic HAF profiling. Experiments were carried out using reverse-phase (RP) and ion-exchange liquid chromatography (LC), in order to detect less and more polar compounds, respectively. RP-LC conditions achieved good separation of amino ac...

  19. Blood flow in cerebral aneurysms: comparison of phase contrast magnetic resonance and computational fluid dynamics - preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Karmonik, C.; Benndorf, G. [The Methodist Hospital Research Inst., Houston (United States). Radiology; Klucznik, R. [The Methodist Hospital, Houston (United States). Radiology

    2008-03-15

    Purpose: computational fluid dynamics (CFD) simulations are increasingly used to model cerebral aneurysm hemodynamics. We investigated the capability of phase contrast magnetic resonance imaging (pcMRI), guided by specialized software for optimal slice definition (NOVA, Vassol Inc.) as a non-invasive method to measure intra-aneurysmal blood flow patterns in-vivo. In a novel approach, these blood flow patterns measured with pcMRI were qualitatively compared to the ones calculated with CFD. Materials end methods: the volumetric inflow rates into three unruptured cerebral aneurysms and the temporal variations of the intra-aneurysmal blood flow patterns were recorded with pcMRI. Transient CFD simulations were performed on geometric models of these aneurysms derived from 3D digital subtraction angiograms. Calculated intra-aneurysmal blood flow patterns were compared at the times of maximum and minimum arterial inflow to the ones measured with pcMRI and the temporal variations of these patterns during the cardiac cycle were investigated. Results: in all three aneurysms, the main features of intra-aneurysmal flow patterns obtained with pcMRI consisted of areas with positive velocities components and areas with negative velocities components. The measured velocities ranged from approx. {+-}60 to {+-}100 cm/sec. Comparison with calculated CFD simulations showed good correlation with regard to the spatial distribution of these areas, while differences in calculated magnitudes of velocities were found. (orig.)

  20. Added value of diffusion-weighted magnetic resonance imaging for the detection of pancreatic fluid collection infection

    Energy Technology Data Exchange (ETDEWEB)

    Borens, Bruno [Polyclinique Santa Maria, Nice (France); Arvanitakis, Marianna; Eisendrath, Pierre; Toussaint, Emmanuel; Deviere, Jacques [Erasme Hospital, Department of Gastroenterology, Brussels (Belgium); Absil, Julie; Matos, Celso; Bali, Maria Antonietta [Erasme Hospital, Department of Radiology, Brussels (Belgium); El Bouchaibi, Said [Epicura, Ath (Belgium)

    2017-03-15

    To investigate the added value of diffusion-weighted (DW) magnetic resonance (MR) imaging in the detection of infection in pancreatic fluid collections (PFC). Forty-patients with PFC requiring endoscopic-transmural drainage underwent conventional-MR and DW-MR imaging (b = 1000 s/mm{sup 2}) before endoscopy. MR images were divided into two sets (set1, conventional-MR; set2, conventional-MR, DW-MR and ADC maps) and randomized. Two independent readers performed qualitative and quantitative (apparent diffusion coefficient, ADC) image analysis. Bacteriological analysis of PFC content was the gold standard. Non-parametric tests were used for comparisons. Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) and accuracy were calculated for the two sets for both readers. Receiver operating characteristic curves (ROC) were drawn to assess quantitative DW-MR imaging diagnostic performance. For both readers, sensitivity, specificity, NPV, PPV and accuracy for infected PFCs were higher for set2 (P >.05). ADC were lower in infected versus non-infected PFCs (P ≤.031). Minimum ADC cut-off: 1,090 x 10{sup -3} mm{sup 2}/s for reader 1 and 1,012 x 10{sup -3} mm{sup 2}/s for reader 2 (sensitivity and specificity 67 % and 96 % for both readers). Qualitative information provided by DW-MR may help to assess PFCs infection. Infected PFCs show significantly lower ADCs compared to non-infected ones. (orig.)

  1. Application of variable threshold intensity to segmentation for white matter hyperintensities in fluid attenuated inversion recovery magnetic resonance images

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Byung Il; Han, Ji Won; Oh, San Yeo Wool; Kim, Tae Hui [Seoul National University Bundang Hospital, Department of Neuropsychiatry, Seongnam, Gyeonggi-do (Korea, Republic of); Lee, Jung Jae; Lee, Eun Young [Kyungbook National University Chilgok Hospital, Department of Psychiatry, Buk-gu, Daegu (Korea, Republic of); MacFall, James R. [Duke University Medical Center, Neuropsychiatric Imaging Research Laboratory, Durham, NC (United States); Duke University Medical Center, Department of Radiology, Durham, NC (United States); Payne, Martha E. [Duke University Medical Center, Neuropsychiatric Imaging Research Laboratory, Durham, NC (United States); Duke University Medical Center, Department of Psychiatry and Behavioral Sciences, Durham, NC (United States); Kim, Jae Hyoung [Seoul National University Bundang Hospital, Department of Radiology, Seongnam, Gyeonggi-do (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Kim, Ki Woong [Seoul National University Bundang Hospital, Department of Neuropsychiatry, Seongnam, Gyeonggi-do (Korea, Republic of); Seoul National University College of Medicine, Department of Psychiatry, Jongno-gu, Seoul (Korea, Republic of); Seoul National University College of Natural Sciences, Department of Brain and Cognitive Science, Gwanak-gu, Seoul (Korea, Republic of)

    2014-04-15

    White matter hyperintensities (WMHs) are regions of abnormally high intensity on T2-weighted or fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI). Accurate and reproducible automatic segmentation of WMHs is important since WMHs are often seen in the elderly and are associated with various geriatric and psychiatric disorders. We developed a fully automated monospectral segmentation method for WMHs using FLAIR MRIs. Through this method, we introduce an optimal threshold intensity (I{sub O}) for segmenting WMHs, which varies with WMHs volume (V{sub WMH}), and we establish the I{sub O} -V{sub WMH} relationship. Our method showed accurate validations in volumetric and spatial agreements of automatically segmented WMHs compared with manually segmented WMHs for 32 confirmatory images. Bland-Altman values of volumetric agreement were 0.96 ± 8.311 ml (bias and 95 % confidence interval), and the similarity index of spatial agreement was 0.762 ± 0.127 (mean ± standard deviation). Furthermore, similar validation accuracies were obtained in the images acquired from different scanners. The proposed segmentation method uses only FLAIR MRIs, has the potential to be accurate with images obtained from different scanners, and can be implemented with a fully automated procedure. In our study, validation results were obtained with FLAIR MRIs from only two scanner types. The design of the method may allow its use in large multicenter studies with correct efficiency. (orig.)

  2. Variation in supratentorial cerebrospinal fluid production rate in one day. Measurement by nontriggered phase-contrast magnetic resonance imaging

    International Nuclear Information System (INIS)

    Takahashi, Hiroto; Tanaka, Hisashi; Fujita, Norihiko; Murase, Kenya; Tomiyama, Noriyuki

    2011-01-01

    Measuring the cerebrospinal fluid (CSF) production rate is important for understanding the physiology related to normal conditions and neurological disorders. Triggered phase-contrast magnetic resonance imaging (MRI) has been used to measure CSF production rate, but the use of nontriggered phase-contrast MRI has not been reported. The purposes of this study were to assess the feasibility of using nontriggered phase-contrast MRI to measure CSF flow and to determine whether CSF production exhibits circadian rhythm. The feasibility of phase-contrast MRI was assessed with a phantom simulated human cerebral aqueduct. CSF flow through the cerebral aqueduct was measured with nontriggered phase-contrast MRI four times during 1 day in 10 normal volunteers. In the phantom study, linear regression analysis gave the following measured values (ml/h): 0.80 x (value of steady flow)-10.0 for triggered phase-contrast MRI and 1.27 x (value of steady flow)-12.2 for nontriggered phase-contrast MRI. One-factor analysis of variance showed no significant effect of the time of the measurements (P=0.47). The supratentorial CSF production rate was 510±549 ml/day (mean ± SD). Nontriggered phase-contrast MRI provided good estimates of the flow rate in the phantom study. We observed no circadian rhythm in CSF production. (author)

  3. Blood flow in cerebral aneurysms: comparison of phase contrast magnetic resonance and computational fluid dynamics - preliminary experience

    International Nuclear Information System (INIS)

    Karmonik, C.; Benndorf, G.; Klucznik, R.

    2008-01-01

    Purpose: computational fluid dynamics (CFD) simulations are increasingly used to model cerebral aneurysm hemodynamics. We investigated the capability of phase contrast magnetic resonance imaging (pcMRI), guided by specialized software for optimal slice definition (NOVA, Vassol Inc.) as a non-invasive method to measure intra-aneurysmal blood flow patterns in-vivo. In a novel approach, these blood flow patterns measured with pcMRI were qualitatively compared to the ones calculated with CFD. Materials end methods: the volumetric inflow rates into three unruptured cerebral aneurysms and the temporal variations of the intra-aneurysmal blood flow patterns were recorded with pcMRI. Transient CFD simulations were performed on geometric models of these aneurysms derived from 3D digital subtraction angiograms. Calculated intra-aneurysmal blood flow patterns were compared at the times of maximum and minimum arterial inflow to the ones measured with pcMRI and the temporal variations of these patterns during the cardiac cycle were investigated. Results: in all three aneurysms, the main features of intra-aneurysmal flow patterns obtained with pcMRI consisted of areas with positive velocities components and areas with negative velocities components. The measured velocities ranged from approx. ±60 to ±100 cm/sec. Comparison with calculated CFD simulations showed good correlation with regard to the spatial distribution of these areas, while differences in calculated magnitudes of velocities were found. (orig.)

  4. Application of variable threshold intensity to segmentation for white matter hyperintensities in fluid attenuated inversion recovery magnetic resonance images

    International Nuclear Information System (INIS)

    Yoo, Byung Il; Han, Ji Won; Oh, San Yeo Wool; Kim, Tae Hui; Lee, Jung Jae; Lee, Eun Young; MacFall, James R.; Payne, Martha E.; Kim, Jae Hyoung; Kim, Ki Woong

    2014-01-01

    White matter hyperintensities (WMHs) are regions of abnormally high intensity on T2-weighted or fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI). Accurate and reproducible automatic segmentation of WMHs is important since WMHs are often seen in the elderly and are associated with various geriatric and psychiatric disorders. We developed a fully automated monospectral segmentation method for WMHs using FLAIR MRIs. Through this method, we introduce an optimal threshold intensity (I O ) for segmenting WMHs, which varies with WMHs volume (V WMH ), and we establish the I O -V WMH relationship. Our method showed accurate validations in volumetric and spatial agreements of automatically segmented WMHs compared with manually segmented WMHs for 32 confirmatory images. Bland-Altman values of volumetric agreement were 0.96 ± 8.311 ml (bias and 95 % confidence interval), and the similarity index of spatial agreement was 0.762 ± 0.127 (mean ± standard deviation). Furthermore, similar validation accuracies were obtained in the images acquired from different scanners. The proposed segmentation method uses only FLAIR MRIs, has the potential to be accurate with images obtained from different scanners, and can be implemented with a fully automated procedure. In our study, validation results were obtained with FLAIR MRIs from only two scanner types. The design of the method may allow its use in large multicenter studies with correct efficiency. (orig.)

  5. Added value of diffusion-weighted magnetic resonance imaging for the detection of pancreatic fluid collection infection

    International Nuclear Information System (INIS)

    Borens, Bruno; Arvanitakis, Marianna; Eisendrath, Pierre; Toussaint, Emmanuel; Deviere, Jacques; Absil, Julie; Matos, Celso; Bali, Maria Antonietta; El Bouchaibi, Said

    2017-01-01

    To investigate the added value of diffusion-weighted (DW) magnetic resonance (MR) imaging in the detection of infection in pancreatic fluid collections (PFC). Forty-patients with PFC requiring endoscopic-transmural drainage underwent conventional-MR and DW-MR imaging (b = 1000 s/mm"2) before endoscopy. MR images were divided into two sets (set1, conventional-MR; set2, conventional-MR, DW-MR and ADC maps) and randomized. Two independent readers performed qualitative and quantitative (apparent diffusion coefficient, ADC) image analysis. Bacteriological analysis of PFC content was the gold standard. Non-parametric tests were used for comparisons. Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) and accuracy were calculated for the two sets for both readers. Receiver operating characteristic curves (ROC) were drawn to assess quantitative DW-MR imaging diagnostic performance. For both readers, sensitivity, specificity, NPV, PPV and accuracy for infected PFCs were higher for set2 (P >.05). ADC were lower in infected versus non-infected PFCs (P ≤.031). Minimum ADC cut-off: 1,090 x 10"-"3 mm"2/s for reader 1 and 1,012 x 10"-"3 mm"2/s for reader 2 (sensitivity and specificity 67 % and 96 % for both readers). Qualitative information provided by DW-MR may help to assess PFCs infection. Infected PFCs show significantly lower ADCs compared to non-infected ones. (orig.)

  6. Delayed clearance of cerebrospinal fluid tracer from entorhinal cortex in idiopathic normal pressure hydrocephalus: A glymphatic magnetic resonance imaging study.

    Science.gov (United States)

    Eide, Per K; Ringstad, Geir

    2018-01-01

    The glymphatic system plays a key role for clearance of waste solutes from the rodent brain. We recently found evidence of glymphatic circulation in the human brain when using magnetic resonance imaging (MRI) contrast agent as cerebrospinal fluid (CSF) tracer in conjunction with multiple MRI acquisitions (gMRI). The present study explored the hypothesis that reduced glymphatic clearance in entorhinal cortex (ERC) may be instrumental in idiopathic normal pressure hydrocephalus (iNPH) dementia. gMRI acquisitions were obtained over a 24-48 h time span in cognitively affected iNPH patients and non-cognitively affected patients with suspected CSF leaks. The CSF tracer enrichment was determined as changes in normalized MRI T1 signal units. The study included 30 patients with iNPH and 8 individuals with suspected CSF leaks (i.e. reference individuals). Compared to reference individuals, iNPH patients presented with higher medial temporal lobe atrophy score and Evan's index and inferior ERC thickness. We found delayed clearance of the intrathecal CSF tracer gadobutrol from CSF, the ERC and adjacent white matter, suggesting impaired glymphatic circulation. Reduced clearance and accumulation of toxic waste product such as amyloid-β may be a mechanism behind dementia in iNPH. Glymphatic MRI (gMRI) may become a tool for assessment of early dementia.

  7. Water volume quantitation using nuclear magnetic resonance imaging: application to cerebrospinal fluid

    International Nuclear Information System (INIS)

    Lecouffe, P.; Huglo, D.; Dubois, P.; Rousseau, J.; Marchandise, X.

    1990-01-01

    Quantitation in proton NMR imaging is applied to cerebrospinal fluid (CSF). Total intracranial CSF volume was measured from Condon's method: CSF signal was compared with distilled water standard signal in a single sagittal thick slice. Brain signal was reduced to minimum using a 5000/360/400 sequence. Software constraints did not permit easy implementing on imager and uniformity correction was performed on a microcomputer. Accuracy was better than 4%. Total intracranial CSF was found between 91 and 164 ml in 5 healthy volunteers. Extraventricular CSF quantitation appears very improved by this method, but planimetric methods seem better in order to quantify ventricular CSF. This technique is compared to total lung water measurement from proton density according to Mac Lennan's method. Water volume quantitation confirms ability of NMR imaging to quantify biologic parameters but image defects have to be known by strict quality control [fr

  8. Cardiac magnetic resonance imaging

    African Journals Online (AJOL)

    2011-03-06

    Mar 6, 2011 ... Cardiac magnetic resonance imaging. Cardiovascular magnetic resonance imaging is becoming a routine diagnostic technique. BRUCE s sPOTTiswOOdE, PhD. MRC/UCT Medical Imaging Research Unit, University of Cape Town, and Division of Radiology, Stellenbosch University. Bruce Spottiswoode ...

  9. Renal transplant failure due to urologic complications: Comparison of static fluid with contrast-enhanced magnetic resonance urography

    Energy Technology Data Exchange (ETDEWEB)

    Blondin, D. [University Hospital Duesseldorf, Institute of Diagnostic Radiology, Moorenstr. 5, D-40225 Duesseldorf (Germany)], E-mail: blondin@med.uni-duesseldorf.de; Koester, A.; Andersen, K.; Kurz, K.D.; Moedder, U.; Cohnen, M. [University Hospital Duesseldorf, Institute of Diagnostic Radiology, Moorenstr. 5, D-40225 Duesseldorf (Germany)

    2009-02-15

    Purpose: Postrenal reasons of renal transplant failure can be assessed by magnetic resonance urography. This study was designed to retrospectively compare the diagnostic accuracy of static fluid (T2-)MRU compared to contrast enhanced (CE-)MRU in patients with renal transplant failure. Material and methods: Thirty-five consecutive patients (14 female, 21 men; mean age 48.6 years) with renal transplant failure and sonographically detected hydronephrosis were examined both with T2-MRU as well as CE-MRU resulting in 39 MRU examinations. MRU was performed both using T2-weighted HASTE-sequence (T2-MRU) as well as Gadolinium-enhanced 3D-FLASH-sequence (CE-MRU) on a 1.5-T clinical MRI scanner (Magnetom Vision, Siemens Medical Solutions). Subjective image quality of resulting maximum intensity projection was assessed in consensus by two readers blinded to the final diagnosis, using a five point scale. MRU findings were correlated to sonography, operative results or clinical follow up. Results: CE-MRU yielded a sensitivity of 85.7% (T2-MRU 76.2%), and a specificity of 83.3% (T2-MRU: 73.7%), however statistical significance was not reached. The subjective image quality was significantly better in CE-MRU. Conclusions: Only concerning subjective image quality CE-MRU proved superior to T2-MRU. Yet, there was no significant difference in diagnostic accuracy between T2- and CE-MRU. Thinking of incipient nephrogenic systemic fibrosis, T2-MRU can be used as reliable alternative in patients with decreased renal transplant function due to urological complications.

  10. Detection of cerebrospinal fluid leakage: initial experience with three-dimensional fast spin-echo magnetic resonance myelography.

    Science.gov (United States)

    Tomoda, Y; Korogi, Y; Aoki, T; Morioka, T; Takahashi, H; Ohno, M; Takeshita, I

    2008-03-01

    The pathogenesis of cerebrospinal fluid (CSF) hypovolemia is supposed to be caused by CSF leakage through small dural defects. To compare source three-dimensional (3D) fast spin-echo (FSE) images of magnetic resonance (MR) myelography with radionuclide cisternography findings, and to evaluate the feasibility of MR myelography in the detection of CSF leakage. A total of 67 patients who were clinically suspected of CSF hypovolemia underwent indium-111 radionuclide cisternography, and 27 of those who had direct findings of CSF leakage were selected for evaluation. MR myelography with 3D FSE sequences (TR/TE 6000/203 ms) was performed at the lumbar spine for all patients. We evaluated source images and maximum intensity projection (MIP) images of MR myelography, and the findings were correlated with radionuclide cisternography findings. MR myelography of five healthy volunteers was used as a reference. The MR visibility of the CSF leakage was graded as definite (leakage clearly visible), possible (leakage poorly seen), or absent (not shown). CSF leakage was identified with source 3D FSE images in 22 (81.5%) of 27 patients. Of the 22 patients, 16 were graded as definite and six were graded as possible. For the definite cases, 3D FSE images clearly showed the extent of the leaked CSF in the paraspinal structures. In the remaining five patients with absent findings, radionuclide cisternography showed only slight radionuclide activity out of the arachnoid space. Source 3D FSE images of MR myelography seem useful in the detection of CSF leakage. Invasive radionuclide cisternography may be reserved for equivocal cases only.

  11. Development of a system for measuring wall shear stress in blood vessels using magnetic resonance imaging and computational fluid dynamics

    International Nuclear Information System (INIS)

    Yoshida, Keita; Nagao, Taisuke; Okada, Kouji; Miyazaki, Shohei; Yang, Xiaomei; Yamazaki, Youichi; Murase, Kenya

    2008-01-01

    We developed a system for measuring the wall shear stress (WSS) in blood vessels using magnetic resonance imaging (MRI) and computational fluid dynamics (CFD). The time-dependent velocity at the center of the blood vessel was measured by phase-contrast MRI and was approximated by finite Fourier series, which was used for generating the velocity profile at the inlet for the boundary condition to the CFD method. To validate the CFD method, we compared the WSS obtained by the CFD method with the theoretical value in a straight cylinder with various radii for both steady and pulsatile flows. We also investigated the dependence of the WSS on the inlet velocity profile incorporated into the CFD method. For steady flow, there was a good agreement between the WSS obtained by the CFD method and the theoretical value. For pulsatile flow, there was a relatively good agreement between them when the radius of the cylinder was 2.5 mm and the inlet velocity profile was given by the Womersley solution for fully developed pulsatile flow in a straight circular cylinder. When the radius of the cylinder was 5 mm and/or the inlet velocity profile was assumed to be parabolic, large differences were observed between them, suggesting that the assumption of fully developed flow does not hold true in these cases. In human studies, the vortex due to the secondary blood flow in the carotid arterial sinus was clearly observed. The WSS in the bifurcation was the highest, while that in the carotid arterial sinus was the smallest. In conclusion, the system presented here appears to be useful for measuring the WSS in blood vessels and for analyzing the cause and/or extent of atherosclerosis, and our results suggest that the inlet velocity profile should be carefully considered. (author)

  12. Renal transplant failure due to urologic complications: Comparison of static fluid with contrast-enhanced magnetic resonance urography

    International Nuclear Information System (INIS)

    Blondin, D.; Koester, A.; Andersen, K.; Kurz, K.D.; Moedder, U.; Cohnen, M.

    2009-01-01

    Purpose: Postrenal reasons of renal transplant failure can be assessed by magnetic resonance urography. This study was designed to retrospectively compare the diagnostic accuracy of static fluid (T2-)MRU compared to contrast enhanced (CE-)MRU in patients with renal transplant failure. Material and methods: Thirty-five consecutive patients (14 female, 21 men; mean age 48.6 years) with renal transplant failure and sonographically detected hydronephrosis were examined both with T2-MRU as well as CE-MRU resulting in 39 MRU examinations. MRU was performed both using T2-weighted HASTE-sequence (T2-MRU) as well as Gadolinium-enhanced 3D-FLASH-sequence (CE-MRU) on a 1.5-T clinical MRI scanner (Magnetom Vision, Siemens Medical Solutions). Subjective image quality of resulting maximum intensity projection was assessed in consensus by two readers blinded to the final diagnosis, using a five point scale. MRU findings were correlated to sonography, operative results or clinical follow up. Results: CE-MRU yielded a sensitivity of 85.7% (T2-MRU 76.2%), and a specificity of 83.3% (T2-MRU: 73.7%), however statistical significance was not reached. The subjective image quality was significantly better in CE-MRU. Conclusions: Only concerning subjective image quality CE-MRU proved superior to T2-MRU. Yet, there was no significant difference in diagnostic accuracy between T2- and CE-MRU. Thinking of incipient nephrogenic systemic fibrosis, T2-MRU can be used as reliable alternative in patients with decreased renal transplant function due to urological complications

  13. Magnetic Resonance Force Microscopy System

    Data.gov (United States)

    Federal Laboratory Consortium — The Magnetic Resonance Force Microscopy (MRFM) system, developed by ARL, is the world's most sensitive nuclear magnetic resonance (NMR) spectroscopic analysis tool,...

  14. Nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Ethier, R.; Melanson, D.; Peters, T.M.

    1983-01-01

    Ten years following computerized tomography, a new technique called nuclear magnetic resonance revolutionizes the field of diagnostic imaging. A major advantage of nuclear magnetic resonance is that the danger of radiation is non-existent as compared to computerized tomography. When parts of the human body are subject to radio-frequencies while in a fixed magnetic field, its most detailed structures are revealed. The quality of images, the applications, as well as the indications are forever increasing. Images obtained at the level of the brain and spinal cord through nuclear magnetic resonance supercede those obtained through computerized tomography. Hence, it is most likely that myelography, along with pneumoencephalography will be eliminated as a diagnostic means. It is without a doubt that nuclear magnetic resonance is tomorrow's computerized tomography [fr

  15. Magnetic Resonance (MR) Defecography

    Science.gov (United States)

    ... to a CD or uploaded to a digital cloud server. Magnetic resonance (MR) defecography is a special ... with you. top of page What are the benefits vs. risks? Benefits MR defecography helps assess pelvic ...

  16. Magnetic resonance angiography (MRA)

    International Nuclear Information System (INIS)

    Arlart, I.P.; Guhl, L.

    1992-01-01

    An account is given in this paper of the physical and technical principles underlying the 'time-of-flight' technique for imaging of vessels by magnetic resonance tomography. Major indications for the new procedure of magnetic resonance angiography at present are intracerebral and extracerebral vessels, with digital subtraction angiography quite often being required to cope with minor alterations (small aneurysms, small occlusions). Magnetic resonance angiography and digital subtraction angiography are compared to each other for advantages and disadvantages. Basically, replacement of radiological angiography by magnetic resonance angiography appears to be possible only within limits, since X-ray diagnostics primarily provides morphological information about vessels, whereas flow dynamics is visualized by the 'time-of-flight' technique. (orig.) [de

  17. Magnetic Resonance Cholangiopancreatography (MRCP)

    Science.gov (United States)

    ... radio waves and a computer to evaluate the liver, gallbladder, bile ducts, pancreas and pancreatic duct for disease. It is ... of the hepatobiliary and pancreatic systems, including the liver, gallbladder, bile ducts, pancreas and pancreatic duct . Magnetic resonance imaging (MRI) ...

  18. Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Robert H. Morris

    2014-11-01

    Full Text Available Magnetic Resonance finds countless applications, from spectroscopy to imaging, routinely in almost all research and medical institutions across the globe. It is also becoming more frequently used for specific applications in which the whole instrument and system is designed for a dedicated application. With beginnings in borehole logging for the petro-chemical industry Magnetic Resonance sensors have been applied to fields as varied as online process monitoring for food manufacture and medical point of care diagnostics. This great diversity is seeing exciting developments in magnetic resonance sensing technology published in application specific journals where they are often not seen by the wider sensor community. It is clear that there is enormous interest in magnetic resonance sensors which represents a significant growth area. The aim of this special edition of Sensors was to address the wide distribution of relevant articles by providing a forum to disseminate cutting edge research in this field in a single open source publication.[...

  19. Magnetic resonance angiography

    Science.gov (United States)

    ... Saunders; 2015:chap 17. Litt H, Carpenter JP. Magnetic resonance imaging. In: Cronenwett JL, Johnston KW, eds. Rutherford's Vascular Surgery . 8th ed. Philadelphia, PA: Elsevier Saunders; 2014:chap ...

  20. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Robertson, Angus

    1990-01-01

    An assessment is made of the clinical benefits of expensive diagnostic technology, such as the magnetic resonance imaging. It is concluded that to most radiologists, magnetic resonance imaging has a definite place in the diagnostic scenario, especially for demonstrating central nervous system lesions in multiple sclerosis. While it is recognized that medical and financial resources are limited, it is emphasised that the cost to society must be balanced against the patient benefit. 17 refs

  1. Nuclear magnetic resonance gyroscope

    International Nuclear Information System (INIS)

    Grover, B.C.

    1984-01-01

    A nuclear magnetic resonance gyro using two nuclear magnetic resonance gases, preferably xenon 129 and xenon 131, together with two alkaline metal vapors, preferably rubidium, potassium or cesium, one of the two alkaline metal vapors being pumped by light which has the wavelength of that alkaline metal vapor, and the other alkaline vapor being illuminated by light which has the wavelength of that other alkaline vapor

  2. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    In a method of imaging a body in which nuclear magnetic resonance is excited in a region including part of the body, and the free induction decay signal is measured, a known quantity of a material of known nuclear magnetic resonance properties, for example a bag of water, is included in the region so as to enhance the measured free induction decay signal. This then reduces the generation of noise during subsequent processing of the signal. (author)

  3. Laser magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Ferrari, C.A.

    1985-01-01

    The technique of laser resonance magnetic resonance allows one to study the high-resolution spectroscopy of transient paramagnetic species, viz, atoms, radicals, and molecular ions. This article is a brief exposition of the method, describing the principles, instrumentation and applicability of the IR and FIR-LMR and shows results of HF + . (Author) [pt

  4. Nuclear Magnetic Resonance Spectroscopy

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 9; Issue 1. Nuclear Magnetic Resonance Spectroscopy. Susanta Das. General Article Volume 9 Issue 1 January 2004 pp 34-49. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/009/01/0034-0049. Keywords.

  5. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Magnetic resonance imaging (MRI) is a new and innovative technique that affords anatomic images in multiple planes and that may provide information about tissue characterization. The magnetic resonance images are obtained by placing the patient or the area of interest within a powerful, highly uniform, static magnetic field. Magnetized protons (hydrogen nuclei) within the patient align like small magnets in this field. Radiofrequency pulses are then used to create an oscillating magnetic field perpendicular to the main field. Magnetic resonance images differ from those produced by x-rays: the latter are associated with absorption of x-ray energy while magnetic resonance images are based on proton density and proton relaxation dynamics. Proton characteristics vary according to the tissue under examination and reflect its physical and chemical properties. To resolve issues regarding safety and efficacy, the Warren Grant Magnuson Clinical Center and the Office of Medical Applications of Research of the National Institutes of Health (NIH) convened a consensus conference about MRI Oct 26 through 28, 1987. At the NIH, the Consensus Development Conference brings together investigators in the biomedical sciences, clinical investigators, practicing physicians, and consumer and special interest groups to make a scientific assessment of technologies, including drugs, devices, and procedures, and to seek agreement on their safety and effectiveness

  6. Nuclear magnetic resonance apparatus

    International Nuclear Information System (INIS)

    Lambert, R.

    1991-01-01

    In order to include the effect of a magnetic object in a subject under investigation, Nuclear Magnetic Resonance (NMR) apparatus is operable at more than one radio frequency (RF) frequency. The apparatus allows normal practice as far as obtaining an NMR response or image from a given nuclear species is concerned, but, in addition, interrogates the nuclear spin system at a frequency which is different from the resonance frequency normally used for the given nuclear species, as determined from the applied magnetic field. The magnetic field close to a magnetised or magnetisable object is modified and the given nuclear species gives a response at the different frequency. Thus detection of a signal at the frequency indicates the presence of the chosen nuclei close to the magnetised or magnetisable object. Applications include validation of an object detection or automatic shape inspection system in the presence of magnetic impurities, and the detection of magnetic particles which affect measurement of liquid flow in a pipe. (author)

  7. Nuclear magnetic resonance scattering

    International Nuclear Information System (INIS)

    Young, I.R.

    1985-01-01

    A nuclear magnetic resonance apparatus is described including a magnet system which is capable of providing a steady magnetic field along an axis, and is constructed so as to define a plurality of regions along the axis in each of which the field is substantially homogeneous so that in each region an imaging operation may be separately carried out. Iron shields increase the field homogeneity. In use, each patient lies on a wheeled trolley which is provided with magnetic field gradient coils and an RF coil system, some of the coils being movable to facilitate positioning of the patient, and there are terminals for connection to a common computing and control facility. (author)

  8. Advances in magnetic resonance 10

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 10, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters that examine superoperators in magnetic resonance; ultrasonically modulated paramagnetic resonance; and the utility of electron paramagnetic resonance (EPR) and electron-nuclear double-resonance (ENDOR) techniques for studying low-frequency modes of atomic fluctuations and their significance for understanding the mechanism of structural phase transitions in solids.

  9. Imaging by magnetic resonance

    International Nuclear Information System (INIS)

    Duroure, J.F.; Serpolay, H.; Vallens, D.

    1995-01-01

    Here are described the advanced technology for nuclear magnetic resonance imaging: reduction of acquisition times, and rebuilding times, images quality improvement. The tendency is to open the machines at low and middle field, on a market being at 10% of NMR I sales, with economical, scientifical and ergonomic reasons broadly developed by constructors

  10. Magnetic resonance fingerprinting.

    Science.gov (United States)

    Ma, Dan; Gulani, Vikas; Seiberlich, Nicole; Liu, Kecheng; Sunshine, Jeffrey L; Duerk, Jeffrey L; Griswold, Mark A

    2013-03-14

    Magnetic resonance is an exceptionally powerful and versatile measurement technique. The basic structure of a magnetic resonance experiment has remained largely unchanged for almost 50 years, being mainly restricted to the qualitative probing of only a limited set of the properties that can in principle be accessed by this technique. Here we introduce an approach to data acquisition, post-processing and visualization--which we term 'magnetic resonance fingerprinting' (MRF)--that permits the simultaneous non-invasive quantification of multiple important properties of a material or tissue. MRF thus provides an alternative way to quantitatively detect and analyse complex changes that can represent physical alterations of a substance or early indicators of disease. MRF can also be used to identify the presence of a specific target material or tissue, which will increase the sensitivity, specificity and speed of a magnetic resonance study, and potentially lead to new diagnostic testing methodologies. When paired with an appropriate pattern-recognition algorithm, MRF inherently suppresses measurement errors and can thus improve measurement accuracy.

  11. Functional Magnetic Resonance Imaging

    Science.gov (United States)

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  12. Nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Rueterjans, H.

    1987-01-01

    Contributions by various authors who are working in the field of NMR imaging present the current status and the perspectives of in-vivo nuclear magnetic resonance spectroscopy, explaining not only the scientific and medical aspects, but also technical and physical principles as well as questions concerning practical organisation and training, and points of main interest for further research activities. (orig./TRV) [de

  13. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    1983-06-01

    This report summarises the aspects of nuclear magnetic resonance imaging (NMRI) considered by the National Health Technology Advisory Panel and makes recommendations on its introduction in Australia with particular regard to the need for thorough evaluation of its cost effectiveness. Topics covered are: principles of the technique, equipment required, installation, costs, reliability, performance parameters, clinical indications, training and staff requirements, and safety considerations

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association ... MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  15. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how ... What is MRI and how does it work? Magnetic resonance imaging, or MRI, is a way of obtaining ...

  16. Magnetic Resonance Imaging of Stroke

    NARCIS (Netherlands)

    Bouts, Mark. J. R. J.; Wu, O.; Dijkhuizen, R. M.

    2017-01-01

    Magnetic resonance imaging (MRI) provides a powerful (neuro)imaging modality for the diagnosis and outcome prediction after (acute) stroke. Since MRI allows noninvasive, longitudinal, and three-dimensional assessment of vessel occlusion (with magnetic resonance angiography (MRA)), tissue injury

  17. Magnetic power piston fluid compressor

    Science.gov (United States)

    Gasser, Max G. (Inventor)

    1994-01-01

    A compressor with no moving parts in the traditional sense having a housing having an inlet end allowing a low pressure fluid to enter and an outlet end allowing a high pressure fluid to exit is described. Within the compressor housing is at least one compression stage to increase the pressure of the fluid within the housing. The compression stage has a quantity of magnetic powder within the housing, is supported by a screen that allows passage of the fluid, and a coil for selectively providing a magnetic field across the magnetic powder such that when the magnetic field is not present the individual particles of the powder are separated allowing the fluid to flow through the powder and when the magnetic field is present the individual particles of the powder pack together causing the powder mass to expand preventing the fluid from flowing through the powder and causing a pressure pulse to compress the fluid.

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  1. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging ( ... the limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  3. Magnetic resonance instrumentation

    International Nuclear Information System (INIS)

    Bell, R.A.

    1987-01-01

    Magnetic resonance (MR), while opening new vistas to diagnostic medicine, utilizes equipment that is unfamiliar to most clinicians. Beyond learning to cope with new terms, such as spin-echo, T1, T2, and spin density, health care professionals are faced with the inclusion of magnetic and radiofrequency effects in their facilities produced by a complex array of devices. It is the purpose of this chapter to outline the components of an MR imaging system, to discuss their functions, and to note the variations in equipment commercially available

  4. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sigal, R.

    1988-01-01

    This book is an introduction to magnetic resonance imaging (MRI). The basic principles for the interpretation of MR images are developed. The book is divided into five chapters: introduction, tissue, parameters, acquisition parameters, contribution to diagnosis, and practical management of an MR examination. Eight exercises allow the reader to test the knowledge he has acquired. Signal localization and MR artefacts are reviewed in an appendix

  5. Magnetic resonance imaging (MRI

    Directory of Open Access Journals (Sweden)

    Takavar A

    1993-04-01

    Full Text Available Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I, a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D. factors and different image construction techniques based on their different combinations is discussed and at the end physical properties of some N.M.R images is mentioned.

  6. Magnetic resonance imaging (MRI)

    OpenAIRE

    Takavar A

    1993-01-01

    Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I), a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D.) factors and different image construction techniques based on their different combinations is discussed and at the end physical properties of some N.M.R images is mentioned.

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... magnetic resonance imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed ... problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it may cause some ...

  8. A study on magnetic relaxation times of various organs and body fluids using superconducting magnetic resonance imaging system part I: measurement of relative signal intensity and T2 relaxation time in various portions of brain and cerebrospinal fluid

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Lee, Ghi Jai; Han, Moon Hee; Kim, Jae Ho; Han, Man Chang; Kim, Chu Wan

    1988-01-01

    This study was undertake to determine if routine clinical magnetic resonance imaging sequences using only two different repetition times (TRs) and with only two sequential echo times (TEs) can be used to measure reproducible relative signal intensity and T2 relaxation time for normal brain tissues and cerebrospinal fluid using a 2.0T superconducting system. In 47 patients 6 different anatomic sites were measured. For each anatomic location, the mean and standard deviation of these values were determined. On T1-weighted (SE 500msec/30msec) images, in globus pallidus and thalamus, of the CSF, cortical gray matter and retrobulbar fat tissue varied more, with a standard deviation of 11-14% on T1-weighted images. On T2-weighted (SE 3000msec/30msec and 3000msec/80msec) images, the relative signal intensity of all anatomic regions varied more than on T1-weighted images. The standard deviation of T2 relaxation times also varied from 10% (fat tissue) to 18% (CSF). These variations might be due to partial volume averaging, signal alteration of CSF secondary to CSF pulsatile motion, etc. Knowing that relative signal intensity and T2 relaxation times calculated from routine imaging sequences are reproducible in only limited area, these normal ranges can be used to investigate changes occurring in disease states of the limited regions.

  9. Evaluation of nuclear magnetic resonance spectroscopy for determination of deuterium abundance in body fluids: application to measurement of total-body water in human infants

    International Nuclear Information System (INIS)

    Rebouche, C.J.; Pearson, G.A.; Serfass, R.E.; Roth, C.W.; Finley, J.W.

    1987-01-01

    Nuclear magnetic resonance (NMR) spectroscopy was used to quantitate abundance of 2H in body water of human infants. This method provides precise measurement of total-body water without the extensive sample preparation requirements of previously described methods for determination of 2H content in body fluids. 2H2O (1 g/kg body weight) was administered to infants and saliva and urine were collected for up to 5 h. An internal standard was added directly to the fluid specimen and 2H enrichment in water was measured by NMR spectroscopy. Working range of deuterium abundance was 0.04-0.32 atom %. Coefficients of variation for saliva samples at 0.20 atom % 2H was 1.97%. 2H content in urine and saliva water reached a plateau by 4 h after administration, and amounts in the two fluids were virtually identical. Mean total-body water determination for six infants was 58.3 +/- 5.8% of body weight (range 53-66%)

  10. Introduction lecture to magnetic resonance

    International Nuclear Information System (INIS)

    Conard, J.

    1980-01-01

    This lecture deals with all that is common either to electron paramagnetic resonance (E.P.R.) or to nuclear magnetic resonance (N.M.R.). It will present, in an as elementary form as possible, the main concepts used in magnetic resonance emphasizing some aspects, specific for interface science. (orig./BHO)

  11. Advanced Nuclear Magnetic Resonance

    OpenAIRE

    Alonso, Diego A.

    2014-01-01

    Transparencias en inglés de la asignatura "Resonancia Magnética Nuclear Avanzada" (Advanced Nuclear Magnetic Resonance) (36643) que se imparte en el Máster de Química Médica como asignatura optativa de 3 créditos ECTS. En esta asignatura se completa el estudio iniciado en la asignatura de quinto curso de la licenciatura en Química "Determinación estructural" (7448) y en la del Grado de Química de tercer curso "Determinación estructural de los compuestos orgánicos" (26030) en lo referente a té...

  12. Cranial magnetic resonance imaging

    International Nuclear Information System (INIS)

    Elster, A.D.

    1988-01-01

    Cranial Magnetic Resonance Imaging is comprehensive, well structured, and well written. The material is current and well referenced. The illustrations are good and complement the text well. The overall quality of publication is above average. The greatest attribute of the book is its readability. The author demonstrates ample skill in making complex subjects, such as MR physics and imaging of cerebral hemorrhage, easy to understand. The book closes with a detailed atlas on the anatomic appearance of the brain on MR images in the axial, coronal, and sagittal planes

  13. Dental magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hilgenfeld, Tim; Bendszus, Martin; Haehnel, Stefan

    2016-01-01

    Growing distribution and utilization of digital volume tomography (DVT) extend the spectrum of clinical dental imaging. Additional diagnostic value, however, comes along with an increasing amount of radiation. In contrast, magnetic resonance imaging is a radiation free imaging technique. Furthermore, it offers a high soft tissue contrast. Morphological and numerical dental anomalies, differentiation of periapical lesions and exclusion of complications of dental diseases are field of applications for dental MRI. In addition, detection of caries and periodontal lesions and injury of inferior alveolar nerve are promising application areas in the future.

  14. Nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Cremin, B.J.

    1981-01-01

    Recent advances in diagnostic imaging, have been the medical application of nuclear magnetic resonance (NMR). It's been used to study the structure of various compounds in chemistry and physics, and in the mid-1970 to produce images of rabbits and eventually of the human hand and head. The images are produced by making use of the nuclear magnetization of the hydrogen ion, or proton, that is present in biological material to record the density distribution of protons in cellular water and lipids. An exploration of the end-results of complicated free induction decay signals, that have been digitized and frequency-analysed by mathematical computerized techniques to produce an image of tissue density, is given. At present NMR produces images comparable to those of early computed tomography

  15. Magnetic resonance angiography in meningovascular syphilis

    Energy Technology Data Exchange (ETDEWEB)

    Gallego, J [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Soriano, G [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Zubieta, J L [Servicio de Neuroradiologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Delgado, G [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Villanueva, J A [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain)

    1994-04-01

    Meningovascular neurosyphilis (MN) is an unusual cause of stroke in young adults. The clinical manifestations include prodromal symptoms weeks or months before definitive stroke. The diagnosis is based on clinical findings and examination of the serum and cerebrospinal fluid. We report a case of MN with basilar artery irregularities demonstrated by magnetic resonance angiography. (orig.)

  16. Magnetic resonance angiography in meningovascular syphilis

    International Nuclear Information System (INIS)

    Gallego, J.; Soriano, G.; Zubieta, J.L.; Delgado, G.; Villanueva, J.A.

    1994-01-01

    Meningovascular neurosyphilis (MN) is an unusual cause of stroke in young adults. The clinical manifestations include prodromal symptoms weeks or months before definitive stroke. The diagnosis is based on clinical findings and examination of the serum and cerebrospinal fluid. We report a case of MN with basilar artery irregularities demonstrated by magnetic resonance angiography. (orig.)

  17. Advances in magnetic resonance 11

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 11, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters and begins with a discussion of the principles and applications of dynamic nuclear polarization, with emphasis on molecular motions and collisions, intermolecular couplings, and chemical interactions. Subsequent chapters focus on the assessment of a proposed broadband decoupling method and studies of time-domain (or Fourier transform) multiple-quantum nuclear magnetic resonance.

  18. Nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Rabenstein, D.L.; Guo, W.

    1988-01-01

    Nuclear magnetic resonance (NMR) spectroscopy is one of the most widely used instrumental methods, with applications ranging from the characterization of pure compounds by high-resolution NMR to the diagnosis of disease by magnetic resonance imaging (MRI). To give some idea of the wide-spread use of NMR, a computer search for the period 1985-1987 turned up over 500 books and review articles and over 7000 literature citations, not including papers in which NMR was used together with other spectroscopic methods for the routine identification of organic compounds. Consequently, they have by necessity been somewhat selective in the topics they have chosen to cover and in the articles they have cited. In this review, which covers the published literature for the approximate period Sept 1985-Aug 1987, they have focused on new developments and applications of interest to the chemist. First they review recent developments in instrumentation and techniques. Although there have not been any major break-throughs in NMR instrumentation during the past two years, significant refinements have been reported which optimize instrumentation for the demanding multiple pulse experiments in routine use today. Next they review new developments in methods for processing NMR data, followed by reviews of one-dimensional and two-dimensional NMR experiments

  19. Advances in magnetic resonance 6

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 6 focuses on the theoretical and practical aspects of applying magnetic resonance methods to various problems in physical chemistry, emphasizing the different aspects of the exegesis of these problems. This book discusses the gas phase magnetic resonance of electronically excited molecules; techniques for observing excited electronic states; NMR studies in liquids at high pressure; and effect of pressure on self-diffusion in liquids. The nuclear magnetic resonance investigations of organic free radicals; measurement of proton coupling constants by NMR; an

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... immediately after the exam. A few patients experience side effects from the contrast material, including nausea and local ... Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... by the interpreting radiologist. Frequently, the differentiation of abnormal (diseased) tissue from normal tissues is better with ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  3. Gastric Fluid Volume Change After Oral Rehydration Solution Intake in Morbidly Obese and Normal Controls: A Magnetic Resonance Imaging-Based Analysis.

    Science.gov (United States)

    Shiraishi, Toshie; Kurosaki, Dai; Nakamura, Mitsuyo; Yazaki, Taiji; Kobinata, Satomi; Seki, Yosuke; Kasama, Kazunori; Taniguchi, Hideki

    2017-04-01

    Although preoperative fluid intake 2 hours before anesthesia is generally considered safe, there are concerns about delayed gastric emptying in obese subjects. In this study, the gastric fluid volume (GFV) change in morbidly obese subjects was investigated after ingesting an oral rehydration solution (ORS) and then compared with that in nonobese subjects. GFV change over time after the ingestion of 500 mL of ORS containing 2.5% carbohydrate (OS-1) was measured in 10 morbidly obese subjects (body mass index [BMI], >35) scheduled for bariatric surgery and 10 nonobese (BMI, 19-24) using magnetic resonance imaging. After 9 hours of fasting, magnetic resonance imaging scans were performed at preingestion, 0 min (just after ingestion), and every 30 minutes up to 120 minutes. GFV values were compared between morbidly obese and control groups and also between preingestion and postingestion time points. The morbidly obese group had a significantly higher body weight and BMI than the control group (mean body weight and BMI in morbidly obese, 129.6 kg and 46.3 kg/m, respectively; control, 59.5 kg and 21.6 kg/m, respectively). GFV was significantly higher in the morbidly obese subjects compared with the control group at preingestion (73 ± 30.8 mL vs 31 ± 19.9 mL, P = .001) and at 0 minutes after ingestion (561 ± 30.8 mL vs 486 ± 42.8 mL; P < .001). GFV declined rapidly in both groups and reached fasting baseline levels by 120 minutes (morbidly obese, 50 ± 29.5 mL; control, 30 ± 11.6 mL). A significant correlation was observed between preingestion residual GFV and body weight (r = .66; P = .001). Morbidly obese subjects have a higher residual gastric volume after 9 hours of fasting compared with subjects with a normal BMI. However, no differences were observed in gastric emptying after ORS ingestion in the 2 populations, and GFVs reached baseline within 2 hours after ORS ingestion. Further studies are required to confirm whether the preoperative fasting and fluid

  4. In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI

    International Nuclear Information System (INIS)

    Isoda, Haruo; Takeda, Hiroyasu; Yamashita, Shuhei; Takehara, Yasuo; Sakahara, Harumi; Ohkura, Yasuhide; Kosugi, Takashi; Hirano, Masaya; Hiramatsu, Hisaya; Namba, Hiroki; Alley, Marcus T.; Bammer, Roland; Pelc, Norbert J.

    2010-01-01

    Hemodynamics is thought to play a very important role in the initiation, growth, and rupture of intracranial aneurysms. The purpose of our study was to perform in vivo hemodynamic analysis of unruptured intracranial aneurysms of magnetic resonance fluid dynamics using time-resolved three-dimensional phase-contrast MRI (4D-Flow) at 1.5 T and to analyze relationships between hemodynamics and wall shear stress (WSS) and oscillatory shear index (OSI). This study included nine subjects with 14 unruptured aneurysms. 4D-Flow was performed by a 1.5-T magnetic resonance scanner with a head coil. We calculated in vivo streamlines, WSS, and OSI of intracranial aneurysms based on 4D-Flow with our software. We evaluated the number of spiral flows in the aneurysms and compared the differences in WSS or OSI between the vessel and aneurysm and between whole aneurysm and the apex of the spiral flow. 3D streamlines, WSS, and OSI distribution maps in arbitrary direction during the cardiac phase were obtained for all intracranial aneurysms. Twelve aneurysms had one spiral flow each, and two aneurysms had two spiral flows each. The WSS was lower and the OSI was higher in the aneurysm compared to the vessel. The apex of the spiral flow had a lower WSS and higher OSI relative to the whole aneurysm. Each intracranial aneurysm in this study had at least one spiral flow. The WSS was lower and OSI was higher at the apex of the spiral flow than the whole aneurysmal wall. (orig.)

  5. In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI.

    Science.gov (United States)

    Isoda, Haruo; Ohkura, Yasuhide; Kosugi, Takashi; Hirano, Masaya; Takeda, Hiroyasu; Hiramatsu, Hisaya; Yamashita, Shuhei; Takehara, Yasuo; Alley, Marcus T; Bammer, Roland; Pelc, Norbert J; Namba, Hiroki; Sakahara, Harumi

    2010-10-01

    Hemodynamics is thought to play a very important role in the initiation, growth, and rupture of intracranial aneurysms. The purpose of our study was to perform in vivo hemodynamic analysis of unruptured intracranial aneurysms of magnetic resonance fluid dynamics using time-resolved three-dimensional phase-contrast MRI (4D-Flow) at 1.5 T and to analyze relationships between hemodynamics and wall shear stress (WSS) and oscillatory shear index (OSI). This study included nine subjects with 14 unruptured aneurysms. 4D-Flow was performed by a 1.5-T magnetic resonance scanner with a head coil. We calculated in vivo streamlines, WSS, and OSI of intracranial aneurysms based on 4D-Flow with our software. We evaluated the number of spiral flows in the aneurysms and compared the differences in WSS or OSI between the vessel and aneurysm and between whole aneurysm and the apex of the spiral flow. 3D streamlines, WSS, and OSI distribution maps in arbitrary direction during the cardiac phase were obtained for all intracranial aneurysms. Twelve aneurysms had one spiral flow each, and two aneurysms had two spiral flows each. The WSS was lower and the OSI was higher in the aneurysm compared to the vessel. The apex of the spiral flow had a lower WSS and higher OSI relative to the whole aneurysm. Each intracranial aneurysm in this study had at least one spiral flow. The WSS was lower and OSI was higher at the apex of the spiral flow than the whole aneurysmal wall.

  6. Magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Meyerhoff, D.J.; Weiner, M.W.

    1989-01-01

    A major function of the liver is regulation of carbohydrate, lipid, and nitrogen metabolism. Food is absorbed by the intestines and transported to the liver by the portal circulation. Substrates are metabolized and stored in the liver to maintain optimal blood concentrations of glucose and lipids. Ammonia generated in the gastrointestinal tract is converted to urea in the liver by the urea cycle. Various forms of liver disease are associated with disorders of carbohydrate, fat, and nitrogen metabolism. Therefore the ability to characterize liver metabolism noninvasively is of potential diagnostic value. Magnetic resonance spectroscopy (MRS) provides information about tissue metabolism by measuring concentrations of metabolites. However, to determine the anatomic location from which spectroscopic signals are derived, MRS could be performed in conjunction with MRI. This paper summarizes the current experience with spectroscopy ion animal models of human disease and reviews the clinical experience with hepatic MRS to date

  7. Magnetic resonance in neuroborreliosis

    International Nuclear Information System (INIS)

    Ustymowicz, A.; Zajkowska, J.

    2003-01-01

    Magnetic resonance (MR) is commonly used in diagnosing infections of the central nervous system. The aim of the study is to evaluate central nervous system changes in neuroborreliosis patients. MR examinations were performed in 44 patients with clinical symptoms, epidemiology and laboratory tests results of neuroborreliosis. Abnormalities were detected in 22 patients. Most of them presented cortico-subcortical atrophy (86%). In 9 cases foci of increased signal in T2-weighted and FLAIR images were observed in white matter. They were single or multiple, located subcorticaly and paraventriculary. In 2 subjects areas of increased signal were found in the brain stem. Central nervous system abnormalities detected with MR are not specific for Lyme disease. They can suggest demyelinating lesions and/or gliosis observed in many nervous system disorders (SM, ADEM, lacunar infarcts). (author)

  8. Cine magnetic resonance

    International Nuclear Information System (INIS)

    Higgins, C.B.; Sechtem, U.P.; Pflugfelder, P.

    1987-01-01

    Cine magnetic resonance (MR) is a fast MR imaging process with referencing of the imaging data to the electrocardiogram (ECG) so that images corresponding to 21-msec segments of the cardiac cycle are acquired. A series of such images, each corresponding to a 21-msec segment of the cardiac cycle, can be laced together for viewing in the cine format at a framing rate of 20 to 40 frames per second. Since cine angiograms of the heart are usually done at 30 frames per second, this technique achieves a temporal resolution adequate for the evluation of central cardiovascular function. The major application of this technique is to depict central cardiovascular function and blood flow

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful ... for an MRI exam contains a metal called gadolinium . Gadolinium can be used in patients with iodine ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... work? Unlike conventional x-ray examinations and computed tomography (CT) scans, MRI does not utilize ionizing radiation. Instead, ... Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging (MRI) Safety Contrast Materials Children ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses ... identify and accurately characterize diseases than other imaging methods. This detail makes MRI an invaluable tool in ...

  12. Magnetic resonance of low dimensional magnetic solids

    Energy Technology Data Exchange (ETDEWEB)

    Gatteschi, D.; Ferraro, F.; Sessoli, R. (Florence Univ. (Italy))

    1994-06-01

    The utility of EPR and NMR in the study of low-dimensional magnetic solids is shown. A short summary of the basis of magnetic resonance in these systems is reported, and the importance of spin-diffusion and magnetic anisotropy evidenced. Some results from experiments on metal-radical chains and clusters are presented. (authors). 37 refs., 7 figs.

  13. Magnetic resonance of low dimensional magnetic solids

    International Nuclear Information System (INIS)

    Gatteschi, D.; Ferraro, F.; Sessoli, R.

    1994-01-01

    The utility of EPR and NMR in the study of low-dimensional magnetic solids is shown. A short summary of the basis of magnetic resonance in these systems is reported, and the importance of spin-diffusion and magnetic anisotropy evidenced. Some results from experiments on metal-radical chains and clusters are presented. (authors). 37 refs., 7 figs

  14. Advances in magnetic resonance 12

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 12, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains six chapters and begins with a discussion of diffusion and self-diffusion measurements by nuclear magnetic resonance. This is followed by separate chapters on spin-lattice relaxation time in hydrogen isotope mixtures; the principles of optical detection of nuclear spin alignment and nuclear quadropole resonance; and the spin-1 behavior, including the relaxation of the quasi-invariants of the motion of a system of pairs of dipolar coupled spin-1/2 nu

  15. Magnetic resonance imaging methodology

    International Nuclear Information System (INIS)

    Moser, Ewald; Stadlbauer, Andreas; Windischberger, Christian; Quick, Harald H.; Ladd, Mark E.

    2009-01-01

    Magnetic resonance (MR) methods are non-invasive techniques to provide detailed, multi-parametric information on human anatomy, function and metabolism. Sensitivity, specificity, spatial and temporal resolution may, however, vary depending on hardware (e.g., field strength, gradient strength and speed) and software (optimised measurement protocols and parameters for the various techniques). Furthermore, multi-modality imaging may enhance specificity to better characterise complex disease patterns. Positron emission tomography (PET) is an interesting, largely complementary modality, which might be combined with MR. Despite obvious advantages, combining these rather different physical methods may also pose challenging problems. At this early stage, it seems that PET quality may be preserved in the magnetic field and, if an adequate detector material is used for the PET, MR sensitivity should not be significantly degraded. Again, this may vary for the different MR techniques, whereby functional and metabolic MR is more susceptible than standard anatomical imaging. Here we provide a short introduction to MR basics and MR techniques, also discussing advantages, artefacts and problems when MR hardware and PET detectors are combined. In addition to references for more detailed descriptions of MR fundamentals and applications, we provide an early outlook on this novel and exciting multi-modality approach to PET/MR. (orig.)

  16. Low field magnetic resonance imaging

    Science.gov (United States)

    Pines, Alexander; Sakellariou, Dimitrios; Meriles, Carlos A.; Trabesinger, Andreas H.

    2010-07-13

    A method and system of magnetic resonance imaging does not need a large homogenous field to truncate a gradient field. Spatial information is encoded into the spin magnetization by allowing the magnetization to evolve in a non-truncated gradient field and inducing a set of 180 degree rotations prior to signal acquisition.

  17. Application of magnetic resonance imaging (MRI) to determine the influence of fluid dynamics on desulfurization in Bench scale reactors

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, N.L.; Reimert, R. [Engler-Bunte-Institut, Bereich Gas, Erdoel und Kohle, Universitaet Karlsruhe (T.H.) (Germany); Hardy, E.H. [Institut fuer Mechanische Verfahrenstechnik und Mechanik, Universitaet Karlsruhe (T.H.) (Germany)

    2006-07-15

    The influence of fluid dynamics on the hydrodesulfurization (HDS) reactions of a diesel oil in bench-scale reactors was evaluated. The porosities and liquid saturations of catalyst beds were quantified by using the MRI technique. The gas-liquid systems used in the experiments were nitrogen diesel and hydrogen diesel. An apparatus was especially constructed, allowing in situ measurements of gas and liquid distributions in packed beds at elevated pressure and temperature up to 20 bar and 200 C, respectively. The reactor itself had a length of 500 mm and an internal diameter of 19 mm. The packed beds used in this MRI study consisted of: (1) 2 mm diameter nonporous spherical glass beads and (2) 1.3 mm diameter porous Al{sub 2}O{sub 3} trilobes having the same size as the original trilobe catalyst used in HDS bench-scale experiments. The superficial gas and liquid velocities were set within the range of trickle flow, e.g., u{sub 0G} = 20-500 mm/s and u{sub 0L} = 0.1-6 mm/s. In parallel with the MRI experiments, the hydrodesulfurization of a gas oil was investigated in a bench-scale plant. Its reactor had the same dimensions of the trickle-bed column used in the MRI experiments and was filled with original trilobe catalyst. These catalytic experiments were carried out at a wide range of operating conditions (p = 30-80 bar, T = 300-380 C, LHSV = 1-4 h{sup -1}). The results of both fluid dynamic and catalytic reaction experiments were then combined for developing a simulation model to predict the HDS performance by accounting for fluid dynamic nonidealities. (Abstract Copyright [2006], Wiley Periodicals, Inc.)

  18. Haemodynamic imaging of thoracic stent-grafts by computational fluid dynamics (CFD): presentation of a patient-specific method combining magnetic resonance imaging and numerical simulations.

    Science.gov (United States)

    Midulla, Marco; Moreno, Ramiro; Baali, Adil; Chau, Ming; Negre-Salvayre, Anne; Nicoud, Franck; Pruvo, Jean-Pierre; Haulon, Stephan; Rousseau, Hervé

    2012-10-01

    In the last decade, there was been increasing interest in finding imaging techniques able to provide a functional vascular imaging of the thoracic aorta. The purpose of this paper is to present an imaging method combining magnetic resonance imaging (MRI) and computational fluid dynamics (CFD) to obtain a patient-specific haemodynamic analysis of patients treated by thoracic endovascular aortic repair (TEVAR). MRI was used to obtain boundary conditions. MR angiography (MRA) was followed by cardiac-gated cine sequences which covered the whole thoracic aorta. Phase contrast imaging provided the inlet and outlet profiles. A CFD mesh generator was used to model the arterial morphology, and wall movements were imposed according to the cine imaging. CFD runs were processed using the finite volume (FV) method assuming blood as a homogeneous Newtonian fluid. Twenty patients (14 men; mean age 62.2 years) with different aortic lesions were evaluated. Four-dimensional mapping of velocity and wall shear stress were obtained, depicting different patterns of flow (laminar, turbulent, stenosis-like) and local alterations of parietal stress in-stent and along the native aorta. A computational method using a combined approach with MRI appears feasible and seems promising to provide detailed functional analysis of thoracic aorta after stent-graft implantation. • Functional vascular imaging of the thoracic aorta offers new diagnostic opportunities • CFD can model vascular haemodynamics for clinical aortic problems • Combining CFD with MRI offers patient specific method of aortic analysis • Haemodynamic analysis of stent-grafts could improve clinical management and follow-up.

  19. Evaluation of Possible Prognostic Factors of Fulminant Acute Disseminated Encephalomyelitis (ADEM) on Magnetic Resonance Imaging with Fluid-Attenuated Inversion Recovery (FLAIR) and Diffusion-Weighted Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Donmez, F.Y.; Aslan, H.; Coskun, M. (Dept. of Radiology, Faculty of Medicine, Baskent Univ., Ankara (Turkey))

    2009-04-15

    Background: Acute disseminated encephalomyelitis (ADEM) may be a rapidly progressive disease with different clinical outcomes. Purpose: To investigate the radiological findings of fulminant ADEM on diffusion-weighted imaging (DWI) and fluid-attenuated inversion recovery (FLAIR) images, and to correlate these findings with clinical outcome. Material and Methods: Initial and follow-up magnetic resonance imaging (MRI) scans in eight patients were retrospectively evaluated for distribution of lesions on FLAIR images and presence of hemorrhage or contrast enhancement. DWI of the patients was evaluated as to cytotoxic versus vasogenic edema. The clinical records were analyzed, and MRI results and clinical outcome were correlated. Results: Four of the eight patients died, three had full recovery, and one had residual cortical blindness. The distribution of the hyperintense lesions on FLAIR sequence was as follows: frontal (37.5%), parietal (50%), temporal (37.5%), occipital (62.5%), basal ganglia (50%), pons (37.5%), mesencephalon (37.5%), and cerebellum (50%). Three of the patients who died had brainstem involvement. Two patients had a cytotoxic edema, one of whom died, and the other developed cortical blindness. Six patients had vasogenic edema: three of these patients had a rapid progression to coma and died; three of them recovered. Conclusion: DWI is not always helpful for evaluating the evolution or predicting the outcome of ADEM. However, extension of the lesions, particularly brainstem involvement, may have an influence on the prognosis.

  20. Clinical significance of cerebrospinal fluid tap test and magnetic resonance imaging/computed tomography findings of tight high convexity in patients with possible idiopathic normal pressure hydrocephalus

    International Nuclear Information System (INIS)

    Ishikawa, Masatsune; Furuse, Motomasa; Nishida, Namiko; Oowaki, Hisayuki; Matsumoto, Atsuhito; Suzuki, Takayuki

    2010-01-01

    Idiopathic normal pressure hydrocephalus (iNPH) is a treatable syndrome with a classical triad of symptoms. The Japanese iNPH guidelines indicate that the cerebrospinal fluid (CSF) tap test and tight high-convexity on magnetic resonance (MR) imaging are important for the diagnosis. The relationships between the effectiveness of CSF shunt surgery in possible iNPH patients, the tap test result, and the MR imaging/computed tomography (CT) findings of tight high-convexity were evaluated in 88 possible iNPH patients (mean age 75 years) with one or more of the classical triad of symptoms, and mild to moderate ventricular dilation. All patients underwent the tap test in the outpatient clinic, and patients and caregivers assessed the clinical changes during one week. The tap test was positive in 47 patients and negative in 41 patients. Surgery was performed in 19 patients with positive tap test, and was effective in 17 patients. Although the findings were inconsistent in some patients, the result of the tap test was found to be highly correlated with the MR imaging/CT finding of tight high-convexity (p<0.0001), confirming that both these diagnostic tests are promising predictors of shunt effectiveness. (author)

  1. Magnetic resonance imaging and computational fluid dynamics (CFD) simulations of rabbit nasal airflows for the development of hybrid CFD/PBPK models.

    Science.gov (United States)

    Corley, R A; Minard, K R; Kabilan, S; Einstein, D R; Kuprat, A P; Harkema, J R; Kimbell, J S; Gargas, M L; Kinzell, John H

    2009-05-01

    The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation. These airflow calculations, along with nasal airway geometry determinations, are critical parameters for hybrid CFD/physiologically based pharmacokinetic models that describe the nasal dosimetry of water-soluble or reactive gases and vapors in rabbits. CFD simulations were based upon three-dimensional computational meshes derived from magnetic resonance images of three adult female New Zealand White (NZW) rabbits. In the anterior portion of the nose, the maxillary turbinates of rabbits are considerably more complex than comparable regions in rats, mice, monkeys, or humans. This leads to a greater surface area to volume ratio in this region and thus the potential for increased extraction of water soluble or reactive gases and vapors in the anterior portion of the nose compared to many other species. Although there was considerable interanimal variability in the fine structures of the nasal turbinates and airflows in the anterior portions of the nose, there was remarkable consistency between rabbits in the percentage of total inspired airflows that reached the ethmoid turbinate region (approximately 50%) that is presumably lined with olfactory epithelium. These latter results (airflows reaching the ethmoid turbinate region) were higher than previous published estimates for the male F344 rat (19%) and human (7%). These differences in regional airflows can have significant implications in interspecies extrapolations of nasal dosimetry.

  2. Parallel magnetic resonance imaging

    International Nuclear Information System (INIS)

    Larkman, David J; Nunes, Rita G

    2007-01-01

    Parallel imaging has been the single biggest innovation in magnetic resonance imaging in the last decade. The use of multiple receiver coils to augment the time consuming Fourier encoding has reduced acquisition times significantly. This increase in speed comes at a time when other approaches to acquisition time reduction were reaching engineering and human limits. A brief summary of spatial encoding in MRI is followed by an introduction to the problem parallel imaging is designed to solve. There are a large number of parallel reconstruction algorithms; this article reviews a cross-section, SENSE, SMASH, g-SMASH and GRAPPA, selected to demonstrate the different approaches. Theoretical (the g-factor) and practical (coil design) limits to acquisition speed are reviewed. The practical implementation of parallel imaging is also discussed, in particular coil calibration. How to recognize potential failure modes and their associated artefacts are shown. Well-established applications including angiography, cardiac imaging and applications using echo planar imaging are reviewed and we discuss what makes a good application for parallel imaging. Finally, active research areas where parallel imaging is being used to improve data quality by repairing artefacted images are also reviewed. (invited topical review)

  3. Noncontrast Magnetic Resonance Lymphography.

    Science.gov (United States)

    Arrivé, Lionel; Derhy, Sarah; El Mouhadi, Sanaâ; Monnier-Cholley, Laurence; Menu, Yves; Becker, Corinne

    2016-01-01

    Different imaging techniques have been used for the investigation of the lymphatic channels and lymph glands. Noncontrast magnetic resonance (MR) lymphography has significant advantages in comparison with other imaging modalities. Noncontrast MR lymphography uses very heavily T2-weighted fast spin echo sequences which obtain a nearly complete signal loss in tissue background and specific display of lymphatic vessels with a long T2 relaxation time. The raw data can be processed with different algorithms such as maximum intensity projection algorithm to obtain an anatomic representation. Standard T2-weighted MR images easily demonstrate the location of edema. It appears as subcutaneous infiltration of soft tissue with a classical honeycomb pattern. True collection around the muscular area may be demonstrated in case of severe lymphedema. Lymph nodes may be normal in size, number, and signal intensity; in other cases, lymph nodes may be smaller in size or number of lymph nodes may be restricted. MR lymphography allows a classification of lymphedema in aplasia (no collecting vessels demonstrated); hypoplasia (a small number of lymphatic vessels), and numerical hyperplasia or hyperplasia (with an increased number of lymphatic vessels of greater and abnormal diameter). Noncontrast MR lymphography is a unique noninvasive imaging modality for the diagnosis of lymphedema. It can be used for positive diagnosis, differential diagnosis, and specific evaluation of lymphedema severity. It may also be used for follow-up evaluation after treatment. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Magnetic resonance imaging. 1

    International Nuclear Information System (INIS)

    Wall, E.E. van der; Roos, A.A. de; Doornbos, J.; Dijkman, P.R.M. van; Matheijssen, N.A.A.; Laarse, A. van der; Krauss, X.H.; Blokland, J.A.k.; Manger Cats, V.; Voorthuisen, A.E. van; Bruschke, A.V.G.

    1991-01-01

    The cardiovascular applications of MRI in coronary artery disease have considerably increased in recent years. Although many applications overlap those of other more cost-effective techniques, such as echocardiography, radionuclide angiography, and CT, MRI offers unique features not shared by the conventional techniques. Technical advantages are the excellent spatial resolution, the characterization of myocardial tissue, and the potential for three-dimensional imaging. This allows the accurate assessment of left ventricular mass and volume, the differentiation of infarcted tissue from normal myocardial tissue, and the determination of systolic wall thickening and regional wall motion abnormalities. Also inducible myocardial ischemia using pharmacological stress (dipyramidole or dobutamine) may be assessed by magnetic resonance imaging. Future technical developments include real-time imaging and noninvasive visualization of the coronary arteries. These advantages will have a major impact on the application of MRI in coronary artery disease, potentially unsurpassed by other techniques and certainly justifying the expenses. Consequently, the clinical use of MRI for the detection of coronary artery disease largely depends on the progress of technical developments. (author). 134 refs.; 10 figs.; 2 tabs

  5. Propagation characteristics of resonance cone in a nonuniform magnetic field

    International Nuclear Information System (INIS)

    Ohnuma, T.; Sanuki, H.

    1984-01-01

    Propagation characteristics of resonance cone field for frequencies below the electron cyclotron frequency are described in a mirror magnetic field on the basis of fluid equation. Theoretical results are compared qualitatively with those of experiment

  6. Advances in magnetic resonance 9

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 9 describes the magnetic resonance in split constants and dipolar relaxation. This book discusses the temperature-dependent splitting constants in the ESR spectra of organic free radicals; temperature-dependent splittings in ion pairs; and magnetic resonance induced by electrons. The electron impact excitation of atoms and molecules; intramolecular dipolar relaxation in multi-spin systems; and dipolar cross-correlation problem are also elaborated. This text likewise covers the NMR studies of molecules oriented in thermotropic liquid crystals and diffusion

  7. Advances in magnetic resonance 1

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 1, discusses developments in various areas of magnetic resonance. The subject matter ranges from original theoretical contributions through syntheses of points of view toward series of phenomena to critical and painstaking tabulations of experimental data. The book contains six chapters and begins with a discussion of the theory of relaxation processes. This is followed by separate chapters on the development of magnetic resonance techniques for studying rate processes in chemistry and the application of these techniques to various problems; the geometri

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... As the hydrogen atoms return to their usual alignment, they emit different amounts of energy that vary ... story about radiology? Share your patient story here Images × Image Gallery Radiologist prepping patient for magnetic resonance ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... As the hydrogen atoms return to their usual alignment, they emit different amounts of energy that vary ... story about radiology? Share your patient story here Images × Image Gallery Magnetic Resonance Imaging (MRI) procedure View ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... or thyroid problems. Any of these conditions may influence the decision on whether contrast material will be ... bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ...

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the technologist or scheduler before the exam. ... patient for magnetic resonance imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the scheduler before the exam and bring ... Image Gallery Magnetic Resonance Imaging (MRI) procedure View full size with caption Pediatric Content Some imaging tests ...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... MRI) exam. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... necessary in trauma situations. Although there is no reason to believe that magnetic resonance imaging harms the ...

  19. Magnetic resonance imaging the basics

    CERN Document Server

    Constantinides, Christakis

    2014-01-01

    Magnetic resonance imaging (MRI) is a rapidly developing field in basic applied science and clinical practice. Research efforts in this area have already been recognized with five Nobel prizes awarded to seven Nobel laureates in the past 70 years. Based on courses taught at The Johns Hopkins University, Magnetic Resonance Imaging: The Basics provides a solid introduction to this powerful technology. The book begins with a general description of the phenomenon of magnetic resonance and a brief summary of Fourier transformations in two dimensions. It examines the fundamental principles of physics for nuclear magnetic resonance (NMR) signal formation and image construction and provides a detailed explanation of the mathematical formulation of MRI. Numerous image quantitative indices are discussed, including (among others) signal, noise, signal-to-noise, contrast, and resolution. The second part of the book examines the hardware and electronics of an MRI scanner and the typical measurements and simulations of m...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... fluid spaces within the brain (ventricles) causes of epilepsy (seizure) hemorrhage in selected trauma patients certain chronic ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  1. Magnetic Resonance Imaging. Chapter 15

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M. O. [The Institute of Cancer Research and The Royal Marsden Hospital, London (United Kingdom)

    2014-09-15

    In Chapter 14, the principles of nuclear magnetic resonance were presented, along with an introduction to image forming processes. In this chapter, magnetic resonance imaging (MRI) will be reviewed, beginning with the hardware needed and its impact on image quality. The acquisition processes and image reconstruction will be discussed, as well as the artefacts that are possible, with discussion of the important area of safety and bioeffects completing the chapter.

  2. The nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Goyer, Ph.

    1997-01-01

    The spectroscopy of nuclear magnetic resonance constitutes a major analytical technique in biological and organic analysis. This technique appears now in the programme of preparatory classes and its teaching is developed in the second year of DEUG. The following article reviews on the nuclear magnetic resonance and on the possibilities it offers to bring to the fore the physico-chemical properties of molecules. (N.C.)

  3. Nuclear magnetic resonance diagnostic apparatus

    International Nuclear Information System (INIS)

    Sugimoto, H.

    1985-01-01

    Nuclear magnetic resonance diagnostic apparatus including a coil for generating a gradient field in a plane perpendicular to a static magnetic field, means for controlling the operation of the coil to rotationally shift in angular steps the gradient direction of the gradient field at an angle pitch of some multiple of the unit index angle through a plurality of rotations to assume all the shift positions of the gradient direction, a rough image reconstructor for reconstructing a rough tomographic image on the basis of nuclear magnetic resonance signals acquired during a rotation of the second gradient magnetic field, a rough image display for depicting the rough tomographic image, a final image reconstructor for reconstructing a final tomographic image on the basis of all nuclear magnetic resonance signals corresponding to all of the expected rotation shift positions acquired during a plurality of rotations and a final image display for depicting the final tomographic image

  4. Nuclear magnetic resonance and earth magnetic field

    International Nuclear Information System (INIS)

    Anon.

    1998-01-01

    Nuclear magnetic resonance concerns nuclei whose spin is different from 0. These nuclei exposed to a magnetic field is comparable to a peg top spinning around its axis while being moved by a precession movement called Larmor precession. This article presents an experiment whose aim is to reveal nuclear magnetism of nuclei by observing Larmor precession phenomena due to the earth magnetic field. The earth magnetic field being too weak, it is necessary to increase the magnetization of the sample during a polarization phase. First the sample is submitted to a magnetic field B perpendicular to the earth magnetic field B 0 , then B is cut off and the nuclei move back to their equilibrium position by executing a precession movement due to B 0 field. (A.C.)

  5. Magnetic Resonance Imaging

    Science.gov (United States)

    ... Permanent cosmetics or tattoos Dentures/teeth with magnetic keepers Other implants that involve magnets Medication patch (i. ... or longer. You’ll be told ahead of time just how long your scan is expected to ...

  6. Noble gas magnetic resonator

    Science.gov (United States)

    Walker, Thad Gilbert; Lancor, Brian Robert; Wyllie, Robert

    2014-04-15

    Precise measurements of a precessional rate of noble gas in a magnetic field is obtained by constraining the time averaged direction of the spins of a stimulating alkali gas to lie in a plane transverse to the magnetic field. In this way, the magnetic field of the alkali gas does not provide a net contribution to the precessional rate of the noble gas.

  7. Magnetic resonance imaging of hypophysis

    International Nuclear Information System (INIS)

    Malla Huesh, I. V.

    2016-01-01

    nuclei and sulci. FLAIR - sequences with its advantage in suppressing the signal from the cerebrospinal fluid is useful in case of meningeal involvement in hypophysitis. DWI is essential in case of ischemia, apoplexy and associated necrotic changes. Contrast medium application is not compulsory, but it increases the sensitivity of the method, especially in young patients. The contrast used is Gadolinium, applied according to the body weight. After contrast application the gland enhances homogeneously. MR-methods made are responsible for throwing light upon the normal images of the pituitary gland from the neonatal patients to adults, explaining the malformative and rare conditions, leading to disturbances in the hypothalamic-pituitary axis. The most common reason for pathologic conditions in the hypothalamic-pituitary axis remain the adenomas. MR-imaging is the method of choice to rule out a suspected formation in the sellar area. Small adenomas with size around 3mm are now detectable with the use of equipment with high strength of magnetic field. Authors agree on the fact the secreting and nonsecreting adenomas need a thorough MR-follow up in time, especially the nonsecreting ones that are usually detected accidentally. In the era before the multislice diagnostic imaging the pathologies in the hypothalamic-pituitary axis were difficult to assess. The introduction of the new methods of investigation made the diagnosis of such conditions achievable. Magnetic resonance imaging is convenient, informative and clinically applicable for detecting hypothalamic-pituitary axis. However there is no agreement how the MR-protocol should be carried out. MR with high magnetic field is an essential tool in obtaining images with better quality, higher diagnostic value and the opportunity for performing sequences in thin slices and reconstructions in different planes. Key words: Magnetic Resonance Imaging. Hypophysis. 3TESLA

  8. Magnetic resonance imaging of aneurysmal subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Ogawa, Toshihide; Shimosegawa, Eku; Inugami, Atsushi; Shishido, Fumio; Fujita, Hideaki; Ito, Hiroshi; Uemura, Kazuo; Yasui, Nobuyuki

    1991-01-01

    Magnetic resonance imaging of subarachnoid hemorrhage (SAH) due to aneurysm rupture was evaluated in relation to CT findings in nine patients. Six patients were studied within 3 days and the other three patients were studied 4 to 6 days from the ictus of SAH using a 0.5 Tesla superconducting unit. In all of the patients, hematoma in the subarachnoid space and ventricles was demonstrated by the proton density-weighted spin echo sequence, which showed that bloody cerebrospinal fluid (CSF) had a higher signal intensity than brain tissue or normal CSF. Magnetic resonance imaging was more sensitive in detecting SAH and more informative as to the site of the ruptured aneurysm than CT. Despite some limitations in applying it to patients with acute SAH, magnetic resonace imaging has clear advantages in the diagnosis of SAH. (author)

  9. Magnetic resonance imaging of aneurysmal subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Toshihide; Shimosegawa, Eku; Inugami, Atsushi; Shishido, Fumio; Fujita, Hideaki; Ito, Hiroshi; Uemura, Kazuo; Yasui, Nobuyuki (Research Inst. of Brain and Blood Vessels, Akita (Japan))

    1991-11-01

    Magnetic resonance imaging of subarachnoid hemorrhage (SAH) due to aneurysm rupture was evaluated in relation to CT findings in nine patients. Six patients were studied within 3 days and the other three patients were studied 4 to 6 days from the ictus of SAH using a 0.5 Tesla superconducting unit. In all of the patients, hematoma in the subarachnoid space and ventricles was demonstrated by the proton density-weighted spin echo sequence, which showed that bloody cerebrospinal fluid (CSF) had a higher signal intensity than brain tissue or normal CSF. Magnetic resonance imaging was more sensitive in detecting SAH and more informative as to the site of the ruptured aneurysm than CT. Despite some limitations in applying it to patients with acute SAH, magnetic resonace imaging has clear advantages in the diagnosis of SAH. (author).

  10. Resting myocardial blood flow quantification using contrast-enhanced magnetic resonance imaging in the presence of stenosis: A computational fluid dynamics study

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Karsten, E-mail: sommerk@uni-mainz.de, E-mail: Schreiber-L@ukw.de [Section of Medical Physics, Department of Radiology, Johannes Gutenberg University Medical Center, Mainz 55131, Germany and Max Planck Graduate Center with the Johannes Gutenberg University Mainz, Mainz 55128 (Germany); Bernat, Dominik; Schmidt, Regine; Breit, Hanns-Christian [Section of Medical Physics, Department of Radiology, Johannes Gutenberg University Medical Center, Mainz 55131 (Germany); Schreiber, Laura M., E-mail: sommerk@uni-mainz.de, E-mail: Schreiber-L@ukw.de [Comprehensive Heart Failure Center, Department of Cardiovascular Imaging, Würzburg University Hospital, Würzburg 97078 (Germany)

    2015-07-15

    Purpose: The extent to which atherosclerotic plaques affect contrast agent (CA) transport in the coronary arteries and, hence, quantification of myocardial blood flow (MBF) using magnetic resonance imaging (MRI) is unclear. The purpose of this work was to evaluate the influence of plaque induced stenosis both on CA transport and on the accuracy of MBF quantification. Methods: Computational fluid dynamics simulations in a high-detailed realistic vascular model were employed to investigate CA bolus transport in the coronary arteries. The impact of atherosclerosis was analyzed by inserting various medium- to high-grade stenoses in the vascular model. The influence of stenosis morphology was examined by varying the stenosis shapes but keeping the area reduction constant. Errors due to CA bolus transport were analyzed using the tracer-kinetic model MMID4. Results: Dispersion of the CA bolus was found in all models and for all outlets, but with a varying magnitude. The impact of stenosis was complex: while high-grade stenoses amplified dispersion, mild stenoses reduced the effect. Morphology was found to have a marked influence on dispersion for a small number of outlets in the post-stenotic region. Despite this marked influence on the concentration–time curves, MBF errors were less affected by stenosis. In total, MBF was underestimated by −7.9% to −44.9%. Conclusions: The presented results reveal that local hemodynamics in the coronary vasculature appears to have a direct impact on CA bolus dispersion. Inclusion of atherosclerotic plaques resulted in a complex alteration of this effect, with both degree of area reduction and stenosis morphology affecting the amount of dispersion. This strong influence of vascular transport effects impairs the accuracy of MRI-based MBF quantification techniques and, potentially, other bolus-based perfusion measurement techniques like computed tomography perfusion imaging.

  11. A neoclassical drift-magnetohydrodynamical fluid model of the interaction of a magnetic island chain with a resonant error-field in a high temperature tokamak plasma

    Science.gov (United States)

    Fitzpatrick, Richard

    2018-04-01

    A two-fluid, neoclassical theory of the interaction of a single magnetic island chain with a resonant error-field in a quasi-cylindrical, low-β, tokamak plasma is presented. The plasmas typically found in large hot tokamaks lie in the so-called weak neoclassical flow-damping regime in which the neoclassical ion stress tensor is not the dominant term in the ion parallel equation of motion. Nevertheless, flow-damping in such plasmas dominates ion perpendicular viscosity, and is largely responsible for determining the phase velocity of a freely rotating island chain (which is in the ion diamagnetic direction relative to the local E × B frame at the rational surface). The critical vacuum island width required to lock the island chain is mostly determined by the ion neoclassical poloidal flow damping rate at the rational surface. The stabilizing effect of the average field-line curvature, as well as the destabilizing effect of the perturbed bootstrap current, is the same for a freely rotating, a non-uniformly rotating, and a locked island chain. The destabilizing effect of the error-field averages to zero when the chain is rotating and only manifests itself when the chain locks. The perturbed ion polarization current has a small destabilizing effect on a freely rotating island chain, but a large destabilizing effect on both a non-uniformly rotating and a locked island chain. This behavior may account for the experimentally observed fact that locked island chains are much more unstable than corresponding freely rotating chains.

  12. Hemodynamic vascular biomarkers for initiation of paraclinoid internal carotid artery aneurysms using patient-specific computational fluid dynamic simulation based on magnetic resonance imaging.

    Science.gov (United States)

    Watanabe, Tomoya; Isoda, Haruo; Takehara, Yasuo; Terada, Masaki; Naito, Takehiro; Kosugi, Takafumi; Onishi, Yuki; Tanoi, Chiharu; Izumi, Takashi

    2018-05-01

    We performed computational fluid dynamics (CFD) for patients with and without paraclinoid internal carotid artery (ICA) aneurysms to evaluate the distribution of vascular biomarkers at the aneurysm initiation sites of the paraclinoid ICA. This study included 35 patients who were followed up for aneurysms using 3D time of flight (TOF) magnetic resonance angiography (MRA) and 3D cine phase-contrast MR imaging. Fifteen affected ICAs were included in group A with the 15 unaffected contralateral ICAs in group B. Thirty-three out of 40 paraclinoid ICAs free of aneurysms and arteriosclerotic lesions were included in group C. We deleted the aneurysms in group A based on the 3D TOF MRA dataset. We performed CFD based on MR data set and obtained wall shear stress (WSS), its derivatives, and streamlines. We qualitatively evaluated their distributions at and near the intracranial aneurysm initiation site among three groups. We also calculated and compared the normalized highest (nh-) WSS and nh-spatial WSS gradient (SWSSG) around the paraclinoid ICA among three groups. High WSS and SWSSG distribution were observed at and near the aneurysm initiation site in group A. High WSS and SWSSG were also observed at similar locations in group B and group C. However, nh-WSS and nh-SWSSG were significantly higher in group A than in group C, and nh-SWSSG was significantly higher in group A than in group B. Our findings indicated that nh-WSS and nh-SWSSG were good biomarkers for aneurysm initiation in the paraclinoid ICA.

  13. Hyperdynamic CSF motion profiles found in idiopathic normal pressure hydrocephalus and Alzheimer's disease assessed by fluid mechanics derived from magnetic resonance images.

    Science.gov (United States)

    Takizawa, Ken; Matsumae, Mitsunori; Hayashi, Naokazu; Hirayama, Akihiro; Yatsushiro, Satoshi; Kuroda, Kagayaki

    2017-10-18

    Magnetic resonance imaging (MRI) does not only ascertain morphological features, but also measures physiological properties such as fluid velocity or pressure gradient. The purpose of this study was to investigate cerebrospinal fluid (CSF) dynamics in patients with morphological abnormalities such as enlarged brain ventricles and subarachnoid spaces. We used a time-resolved three dimensional phase contrast (3D-PC) MRI technique to quantitatively evaluate CSF dynamics in the Sylvian aqueduct of healthy elderly individuals and patients with either idiopathic normal pressure hydrocephalus (iNPH) or Alzheimer's disease (AD) presenting with ventricular enlargement. Nineteen healthy elderly individuals, ten iNPH patients, and seven AD patients (all subjects ≥ 60 years old) were retrospectively evaluated 3D-PC MRI. The CSF velocity, pressure gradient, and rotation in the Sylvian aqueduct were quantified and compared between the three groups using Kolmogorov-Smirnov and Mann-Whitney U tests. There was no statistically significant difference in velocity among the three groups. The pressure gradient was not significantly different between the iNPH and AD groups, but was significantly different between the iNPH group and the healthy controls (p < 0.001), and similarly, between the AD group and the healthy controls (p < 0.001). Rotation was not significantly different between the iNPH and AD groups, but was significantly different between the iNPH group and healthy controls (p < 0.001), and similarly, between the AD group and the healthy controls (p < 0.001). Quantitative analysis of CSF dynamics with time resolved 3D-PC MRI revealed differences and similarities in the Sylvian aqueduct between healthy elderly individuals, iNPH patients, and AD patients. The results showed that CSF motion is in a hyperdynamic state in both iNPH and AD patient groups compared to healthy elderly individuals, and that iNPH patients and AD patients display similar CSF motion profiles.

  14. Fourier transform nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Geick, R.

    1981-01-01

    This review starts with the basic principles of resonance phenomena in physical systems. Especially, the connection is shown between the properties of these systems and Fourier transforms. Next, we discuss the principles of nuclear magnetic resonance. Starting from the general properties of physical systems showing resonance phenomena and from the special properties of nuclear spin systems, the main part of this paper reviews pulse and Fourier methods in nuclear magnetic resonance. Among pulse methods, an introduction will be given to spin echoes, and, apart from the principle of Fourier transform nuclear magnetic resonance, an introduction to the technical problems of this method, e.g. resolution in the frequency domain, aliasing, phase and intensity errors, stationary state of the spin systems for repetitive measurements, proton decoupling, and application of Fourier methods to systems in a nonequilibrium state. The last section is devoted to special applications of Fourier methods and recent developments, e.g. measurement of relaxation times, solvent peak suppression, 'rapid scan'-method, methods for suppressing the effects of dipolar coupling in solids, two-dimensional Fourier transform nuclear magnetic resonance, and spin mapping or zeugmatography. (author)

  15. Suppressing magnetic island growth by resonant magnetic perturbation

    Science.gov (United States)

    Yu, Q.; Günter, S.; Lackner, K.

    2018-05-01

    The effect of externally applied resonant magnetic perturbations (RMPs) on the growth of magnetic islands is investigated based on two-fluid equations. It is found that if the local bi-normal electron fluid velocity at the resonant surface is sufficiently large, static RMPs of the same helicity and of moderate amplitude can suppress the growth of magnetic islands in high-temperature plasmas. These islands will otherwise grow, driven by an unfavorable plasma current density profile and bootstrap current perturbation. These results indicate that the error field can stabilize island growth, if the error field amplitude is not too large and the local bi-normal electron fluid velocity is not too low. They also indicate that applied rotating RMPs with an appropriate frequency can be utilized to suppress island growth in high-temperature plasmas, even for a low bi-normal electron fluid velocity. A significant change in the local equilibrium plasma current density gradient by small amplitude RMPs is found for realistic plasma parameters, which are important for the island stability and are expected to be more important for fusion reactors with low plasma resistivity.

  16. Magnetic resonance and porous materials

    International Nuclear Information System (INIS)

    McDonald, P.; Strange, J.

    1998-01-01

    Mention the words magnetic resonance to your medical advisor and he or she will immediately think of a multi-million pound scanner that peers deep into the brain. A chemist, on the other hand, will imagine a machine that costs several hundred thousand pounds and produces high-resolution spectra for chemical analysis. Food technologists will probably think of a bench-top instrument for determining moisture content, while an oil prospector will envisage a device that can be operated several kilometres down an oil well. To a physicist the term is more likely to conjure up a mental picture of nuclear spins precessing in a magnetic field. These examples illustrate the diverse aspects of a phenomenon discovered by physicists over 50 years ago. Electron spin resonance was first discovered by Russian scientists, and nuclear magnetic resonance was discovered in the US shortly afterwards by Ed Purcell at Harvard University and Felix Bloch at Stanford University. Today, nuclear magnetic resonance (NMR) is the most widely used technique. Modern NMR machines are making it possible to probe microstructure and molecular movement in materials as diverse as polymers, cements, rocks, soil and foods. NMR allows the distribution of different components in a material to be determined with a resolution approaching 1μm, although the signal can be sensitive to even smaller lengthscales. In this article the authors describe how physicists are still developing magnetic resonance to exploit a range of new applications. (UK)

  17. EXPERIMENTAL STUDY OF MAGNETIC FLUID SEAL

    Directory of Open Access Journals (Sweden)

    V. G. Bashtovoi

    2006-01-01

    Full Text Available Dependences of critical pressure drop, being held by magnetic fluid seal, on time in a static state and shaft rotation velocity in dynamics have been experimentally determined. The significant influence of particles’ redistribution in magnetic fluid on static parameters of magnetic fluid seal has been established.

  18. GHz nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Cross, T.A.; Drobny, G.; Trewhella, J.

    1994-12-01

    For the past dozen years, 500- and 600-MHz spectrometers have become available in many laboratories. The first 600-MHz NMR spectrometer (at Carnegie Mellon University) was commissioned more than 15 years ago and, until 1994, represented the highest field available for high-resolution NMR. This year, we have witnessed unprecedented progress in the development of very high field magnets for NMR spectroscopy, including the delivery of the first commercial 750-MHz NMR spectrometers. In addition, NMR signals have been obtained from 20-Tesla magnets (850 MHz for {sup 1}H`s) at both Los Alamos National Laboratory and Florida State University in the NHMFL (National High Magnetic Field Laboratory). These preliminary experiments have been performed in magnets with 100-ppm homogeneity, but a 20-Tesla magnet developed for the NHMFL will be brought to field this year with a projected homogeneity of 0.1 ppm over a 1-cm-diam spherical volume.

  19. Principles of magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mlynarik, V.; Tkac, I.; Srbecky, M.

    1995-01-01

    The aim of this review is to describe and explain the basic principles of magnetic resonance imaging. The first part of the text is devoted to the phenomenon of magnetic resonance (the interaction of RF magnetic field with the set of magnetic moments in the homogeneous magnetic field) and to relaxation processes. Then, the creation of MR image is described (slice selection, phase and frequency encoding of spatial information). The basic and the most frequently used techniques are explained (spin echo, gradient echo). The way the repetition and echo times influence the image quality and contrast (T1 or T2 weighing) is described. The part with the technical description of the MR equipment is included in the review. The MR imagination examination are compared with X-ray computer tomography technique

  20. Bifurcation magnetic resonance in films magnetized along hard magnetization axis

    Energy Technology Data Exchange (ETDEWEB)

    Vasilevskaya, Tatiana M., E-mail: t_vasilevs@mail.ru [Ulyanovsk State University, Leo Tolstoy 42, 432017 Ulyanovsk (Russian Federation); Sementsov, Dmitriy I.; Shutyi, Anatoliy M. [Ulyanovsk State University, Leo Tolstoy 42, 432017 Ulyanovsk (Russian Federation)

    2012-09-15

    We study low-frequency ferromagnetic resonance in a thin film magnetized along the hard magnetization axis performing an analysis of magnetization precession dynamics equations and numerical simulation. Two types of films are considered: polycrystalline uniaxial films and single-crystal films with cubic magnetic anisotropy. An additional (bifurcation) resonance initiated by the bistability, i.e. appearance of two closely spaced equilibrium magnetization states is registered. The modification of dynamic modes provoked by variation of the frequency, amplitude, and magnetic bias value of the ac field is studied. Both steady and chaotic magnetization precession modes are registered in the bifurcation resonance range. - Highlights: Black-Right-Pointing-Pointer An additional bifurcation resonance arises in a case of a thin film magnetized along HMA. Black-Right-Pointing-Pointer Bifurcation resonance occurs due to the presence of two closely spaced equilibrium magnetization states. Black-Right-Pointing-Pointer Both regular and chaotic precession modes are realized within bifurcation resonance range. Black-Right-Pointing-Pointer Appearance of dynamic bistability is typical for bifurcation resonance.

  1. Bifurcation magnetic resonance in films magnetized along hard magnetization axis

    International Nuclear Information System (INIS)

    Vasilevskaya, Tatiana M.; Sementsov, Dmitriy I.; Shutyi, Anatoliy M.

    2012-01-01

    We study low-frequency ferromagnetic resonance in a thin film magnetized along the hard magnetization axis performing an analysis of magnetization precession dynamics equations and numerical simulation. Two types of films are considered: polycrystalline uniaxial films and single-crystal films with cubic magnetic anisotropy. An additional (bifurcation) resonance initiated by the bistability, i.e. appearance of two closely spaced equilibrium magnetization states is registered. The modification of dynamic modes provoked by variation of the frequency, amplitude, and magnetic bias value of the ac field is studied. Both steady and chaotic magnetization precession modes are registered in the bifurcation resonance range. - Highlights: ► An additional bifurcation resonance arises in a case of a thin film magnetized along HMA. ► Bifurcation resonance occurs due to the presence of two closely spaced equilibrium magnetization states. ► Both regular and chaotic precession modes are realized within bifurcation resonance range. ► Appearance of dynamic bistability is typical for bifurcation resonance.

  2. Recommendations concerning magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    1986-01-01

    In medicine the technique of nuclear magnetic resonance (NMR) is applied in the form of in vivo nuclear magnetic resonance spectroscopy (MRS). In vivo MRS can be carried out non-invasively. The committee of the Dutch Health Council briefly discusses the qualities and potentialities of the nuclei that will probably be used in future clinical spectroscopy: 31 P, 13 C, 1 H (and possibly 19 F and 23 Na). The committee discusses several possibilities of combining imaging and spectroscopy. The imaging of nuclei other than protons is also possible with MRS. Potential applications are considered in oncology, cardiology, neurology and hepatology. (Auth.)

  3. Migraine and magnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Younis, Samaira; Hougaard, Anders; Vestergaard, Mark B.

    2017-01-01

    Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation in the meth......Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation...

  4. Evanescent Waves Nuclear Magnetic Resonance

    DEFF Research Database (Denmark)

    Halidi, El Mohamed; Nativel, Eric; Akel, Mohamad

    2016-01-01

    Nuclear Magnetic Resonance spectroscopy and imaging can be classified as inductive techniques working in the near- to far-field regimes. We investigate an alternative capacitive detection with the use of micrometer sized probes positioned at sub wavelength distances of the sample in order...

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Magnetic Resonance Imaging Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... about radiology? Share your patient story here Images ... Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ...

  12. Magnetic Resonance Imaging (MRI): Brain (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Brain KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Brain What's in this article? What ...

  13. Advances in magnetic and optical resonance

    CERN Document Server

    Warren, Warren S

    1997-01-01

    Since 1965, Advances in Magnetic and Optical Resonance has provided researchers with timely expositions of fundamental new developments in the theory of, experimentation with, and application of magnetic and optical resonance.

  14. Magnetic resonance for wireless power transfer

    OpenAIRE

    Hui, SYR

    2016-01-01

    Magnetic resonance has been a cornerstone of nonradiative wireless power transfer (WPT) since the late 19th century. However, some researchers have the misconception that magnetic resonance for WPT was developed recently. This article traces some early work of Tesla and other researchers related to the use of magnetic resonance in WPT. Included are some examples of magnetic resonance-based WPT projects conducted by researchers in the biomedical and power electronics communities over the last ...

  15. Magnetic resonance of the renal transplantation

    International Nuclear Information System (INIS)

    Cauquil, P.; Hiesse, C.; Say, C.; Verdier, J.P.; Cauquil, M.; Brunet, A.M.; Galindo, R.; Tessier, J.P.

    1989-01-01

    Renal transplantation is the treatment of choice for renal insufficiency. Progress of surgical techniques and immuno-suppression have lead to better results. One year graft survival rate are 80% in most series. In this article, the role of imaging in renal transplantation, is defined. In surgical complications (fluid collections, obstruction, vascular insufficiency) non invasive radiology and interventionnal radiologic procedures have a great impact. Despite the perspectives of duplex and magnetic resonance, sensibility and specificity are not yet specified in medical complications: rejection, acute tubular necrosis, infection, drug toxicity. Association of these lesions is frequent and complicate analysis of results. Finally, transplant biopsy is still necessary to confirm the diagnosis [fr

  16. Magnetic resonance tomography in syringomyelia

    International Nuclear Information System (INIS)

    Koehler, D.; Treisch, J.; Hertel, G.; Schoerner, W.; Fiegler, W.; Staedtisches Rudolf-Virchow Krankenhaus, Berlin

    1985-01-01

    Thirteen patients with a clinical diagnosis of syringomyelia were examined by nuclear tomography (0.35 T magnet) in the spin-echo mode. In all thirteen patients, the T1 images (Se 400/35) showed a longitudinal cavity with a signal intensity of CSF. The shape and extent of the syrinx could be adequately demonstrated in 12 of the 13 examinations. Downward displacement of the cerebellar tonsils was seen in eight cases. The examination took between half and one hour. Advantages of magnetic resonance tomography (nuclear tomography) include the absence of artifacts, images in the line of the lesion and its non-invasiveness. (orig.) [de

  17. Limits to magnetic resonance microscopy

    International Nuclear Information System (INIS)

    Glover, Paul; Mansfield, Peter

    2002-01-01

    The last quarter of the twentieth century saw the development of magnetic resonance imaging (MRI) grow from a laboratory demonstration to a multi-billion dollar worldwide industry. There is a clinical body scanner in almost every hospital of the developed nations. The field of magnetic resonance microscopy (MRM), after mostly being abandoned by researchers in the first decade of MRI, has become an established branch of the science. This paper reviews the development of MRM over the last decade with an emphasis on the current state of the art. The fundamental principles of imaging and signal detection are examined to determine the physical principles which limit the available resolution. The limits are discussed with reference to liquid, solid and gas phase microscopy. In each area, the novel approaches employed by researchers to push back the limits of resolution are discussed. Although the limits to resolution are well known, the developments and applications of MRM have not reached their limit. (author)

  18. Magnetic resonance and its applications

    CERN Document Server

    Chizhik, Vladimir I; Donets, Alexey V; Frolov, Vyacheslav V; Komolkin, Andrei V; Shelyapina, Marina G

    2014-01-01

    The book provides a basic understanding of the underlying theory, fundamentals and applications of magnetic resonance The book implies a few levels of the consideration (from simple to complex) of phenomena, that can be useful for different groups of readers The introductory chapter provides the necessary underpinning knowledge for newcomers to the methods The exposition of theoretical materials goes from initial to final formulas through detailed intermediate expressions.

  19. Thin-Film Magnetic-Field-Response Fluid-Level Sensor for Non-Viscous Fluids

    Science.gov (United States)

    Woodard, Stanley E.; Shams, Qamar A.; Fox, Robert L.; Taylor, Bryant D.

    2008-01-01

    An innovative method has been developed for acquiring fluid-level measurements. This method eliminates the need for the fluid-level sensor to have a physical connection to a power source or to data acquisition equipment. The complete system consists of a lightweight, thin-film magnetic-field-response fluid-level sensor (see Figure 1) and a magnetic field response recorder that was described in Magnetic-Field-Response Measurement-Acquisition System (LAR-16908-1), NASA Tech Briefs, Vol. 30, No. 6 (June 2006), page 28. The sensor circuit is a capacitor connected to an inductor. The response recorder powers the sensor using a series of oscillating magnetic fields. Once electrically active, the sensor responds with its own harmonic magnetic field. The sensor will oscillate at its resonant electrical frequency, which is dependent upon the capacitance and inductance values of the circuit.

  20. Dielectric studies of fluids with reentrant resonators

    International Nuclear Information System (INIS)

    Goodwin, A.R.H.; Moldover, M.R.

    1993-01-01

    The authors have used a reentrant radio-frequency (rf) cavity as a resonator operating near 375 MHz to measure changes in the dielectric constant of fluids within it. The utility of these measurements was demonstrated by determining the dipole moment of 1,1,1,2,3,3-hexafluoropropane, a candidate replacement refrigerant (denoted R236ea) and by detecting the phase boundaries in the mixture [(1-x)C 2 H 6 + xCO 2 ], for the mole fraction x = 0.492. The densities of the coexisting phases of the mixture were determined using the Clausius-Mossotti relation which has errors on the order of 0.5% in this application. To test the accuracy of the present techniques, the rf resonator was calibrated with helium and then used to redetermine the molar polarizability A e of argon. The results were in excellent agreement with published values. The design of the reentrant resonator makes it suitable for use with corrosive fluids at temperature up to 400 degrees C

  1. Hydrodynamic bearing lubricated with magnetic fluids

    International Nuclear Information System (INIS)

    Urreta, H; Leicht, Z; Sanchez, A; Agirre, A; Kuzhir, P; Magnac, G

    2009-01-01

    This paper summarizes the work carried out in the development of hydrodynamic lubricated journal bearings with magnetic fluids. Two different fluids have been analyzed, one ferrofluid from FERROTEC APG s10n and one magnetorheological fluid from LORD Corp., MRF122-2ED. Theoretical analysis has been carried out with numerical solutions of Reynolds equation, based on apparent viscosity modulation for ferrofluid and Bingham model for MR fluid. To validate this model, one test bench has been designed, manufactured and set up, where preliminary results shown in this paper demonstrate that magnetic fluids can be used to develop active journal bearings.

  2. The nuclear magnetic resonance well logging

    International Nuclear Information System (INIS)

    Zhang Yumin; Shen Huitang

    2003-01-01

    In this paper, the characteristic of the nuclear magnetic resonance logging is described at first. Then its development and its principle is presented. Compared with the nuclear magnetic resonance spectrometer, the magnet techniques is the first question that we must solve in the manufacture of the NMR well logging

  3. Temporal stability of superposed magnetic fluids in porous media

    International Nuclear Information System (INIS)

    Zakaria, Kadry; Sirwah, Magdy A; Alkharashi, Sameh

    2008-01-01

    The present work deals with the stability properties of time periodically streaming superposed magnetic fluids through porous media under the influence of an oblique alternating magnetic field. The system is composed of a middle fluid sheet of finite thickness embedded between two other bounded layers. The fluids are assumed to be incompressible and there are no volume charges in the layers of the fluids. Such configurations are of relevance in a variety of astrophysical and space configurations. The solutions of the linearized equations of motion and boundary conditions lead to deriving two more general simultaneous Mathieu equations of damping terms with complex coefficients. The method of multiple time scales is used to obtain approximate solutions and analyze the stability criteria for both the non-resonant and resonant cases and hence transition curves are obtained for such cases. The stability criteria are examined theoretically and numerically from which stability diagrams are obtained. It is found that the fluid sheet thickness plays a destabilizing role in the presence of a constant field and velocity, while the damping role is observed for the resonant cases. Dual roles are observed for the fluid velocity and the porosity in the stability criteria

  4. Magnetic resonance imaging at Rikshospitalet

    International Nuclear Information System (INIS)

    Smith, H.J.

    1990-01-01

    During the first 18 months of operations of the nuclear magnetic resonance (NMR) unit at Rikshospitalet, 1453 NMR examinations have been performed on 1431 patients. 64% of the time has been devoted to examinations of the central nervous system and spine in children and adults, 9% of the time has been used on non-neuroradiology pediatric patients, while the rest of the time has been spent equally on ear, nose and throat, thoracic (including cardiac) and abdominal examinations in adult patients. The indications for doing NMR at Rikshospitalet are listed and discussed, and it is concluded that NMR has proved to be useful at several conditions in most organ systems. 15 refs

  5. Magnetic resonance imaging in psychiatry

    International Nuclear Information System (INIS)

    Mann, K.

    1993-01-01

    Diagnosis and research in psychiatry are increasingly availing themselves of magnetic resonance imaging (MRI). In comparison to computed tomography (CT), this offers the combined benefits of no exposure to radiation, high resolution, artefact-free display of structures near bone, and a sharp contrast between the grey and white brain matter, with freedom to select the section. With the exception of very anxious patients, MRI will gradually replace CT scans for a wide range of differential diagnostic investigations. Its superiority in systematic studies of psychiatric patients with discrete cerebral parenchyma lesions is already considered proven. This is illustrated on the basis of research into schizophrenia and alcoholism. (orig.) [de

  6. Advances in magnetic resonance 3

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 3, describes a number of important developments which are finding increasing application by chemists. The book contains five chapters and begins with a discussion of how the properties of random molecular rotations reflect themselves in NMR and how they show up, often differently, in other kinds of experiments. This is followed by separate chapters on the Kubo method, showing its equivalence to the Redfield approach in the cases of most general interest; the current state of dynamic nuclear polarization measurements in solutions and what they tell us abou

  7. Resonant and nonresonant magnetic scattering (invited)

    International Nuclear Information System (INIS)

    McWhan, D.B.; Hastings, J.B.; Kao, C.; Siddons, D.P.

    1992-01-01

    The tunability and the polarization of synchrotron radiation open up new possibilities for the study of magnetism. Studies on magnetic materials performed at the National Synchrotron Light Source are reviewed, and they fall into four areas: structure, evolution of magnetic order, separation of L and S, and resonance effects. In the vicinity of atomic absorption edges, the Faraday effect, magnetic circular dichroism, and resonant magnetic scattering are all related resonance effects which measure the spin-polarized density of states. The production and analysis of polarized beams are discussed in the context of the study of magnetism with synchrotron radiation

  8. The dynamic behavior of magnetic fluid adsorbed to small permanent magnet in alternating magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Sudo, Seiichi, E-mail: sudo@akita-pu.ac.j [Faculty of Systems Science and Technology, Akita Prefectural University, Ebinokuchi 84-4, Yurihonjo 015-0055 (Japan); Asano, Daisaku [Faculty of Systems Science and Technology, Akita Prefectural University, Ebinokuchi 84-4, Yurihonjo 015-0055 (Japan); Takana, Hidemasa; Nishiyama, Hideya [Institute of Fluid Science, Tohoku University, Katahira 2-1-1, Aobaku, Sendai 980-8577 (Japan)

    2011-05-15

    The dynamic behavior of a magnetic fluid adsorbed to a small NdFeB permanent magnet subjected to an alternating magnetic field was studied with a high speed video camera system. The directions of alternating magnetic field are parallel and opposite to that of the permanent magnet. It was found that the surface of magnetic fluid responds to the external alternating magnetic field in elongation and contraction with a lot of spikes. Generation of a capillary magnetic fluid jet was observed in the neighbourhood of a specific frequency of alternating field. The effect of gravitational force on surface phenomena of magnetic fluid adsorbed to the permanent magnet was revealed. - Research Highlights: Magnetic fluid of the system responds to alternating magnetic field with higher frequencies. Large-amplitude surface motions of magnetic fluid occur at the specific frequencies of the external field. Capillary jets of magnetic fluid are generated at the natural frequency of the system.

  9. Tunable Magnetic Resonance in Microwave Spintronics Devices

    Science.gov (United States)

    Chen, Yunpeng; Fan, Xin; Xie, Yunsong; Zhou, Yang; Wang, Tao; Wilson, Jeffrey D.; Simons, Rainee N.; Chui, Sui-Tat; Xiao, John Q.

    2015-01-01

    Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe based tunable microwave spintronics devices, which is 10X higher than conventional methods.

  10. Magnetic resonance imaging of Parkinsonism

    International Nuclear Information System (INIS)

    Mukai, Eiichiro; Makino, Naoki; Fujishiro, Kenichiro.

    1989-01-01

    We have analyzed magnetic resonance images in 33 patients; 18 patients with Parkinson's disease, 1 patient with diurnally fluctuating progressive dystonia, 1 patient with pure akinesia, 6 patients with multiple system atrophy, 1 patient with flunarizine induced parkinsonism, and 4 patients with unclassified parkinsonism. The MR images were obtained using a 1.5-T GE MR System. A spin-echo pulse sequence was used with a TE of 30 msec and 80 msec and a TR of 2000 msec. No signal abnormalities were seen in any patient with Parkinson's disease but 3 showed slightly decreased signal intensity of the putamen on T2-weighted sequences. Patients with diurnally fluctuating progressive dystonia and pure akinesia evidensed no abnormal findings. All six patients with multiple system atrophy demonstrated decreased signal intensity of the putamen, particularly along their lateral and posterior portions, and an enlarged substantia nigra. Atrophy of the pons and cerebellum was detected in all cases with multiple system atrophy. One case of flunarizine induced parkinsonism showed slightly decreased signal intensity of the putamen. Four cases of unclassified parkinsonism showed decreased signal in the putamen on T2-weighted sequences. Magnetic resonance imaging has the potential to become a useful diagnostic tool in the management of parkinsonism. (author)

  11. Magnetic resonance imaging of Parkinsonism

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, Eiichiro [National Hospital of Nagoya (Japan); Makino, Naoki; Fujishiro, Kenichiro

    1989-06-01

    We have analyzed magnetic resonance images in 33 patients; 18 patients with Parkinson's disease, 1 patient with diurnally fluctuating progressive dystonia, 1 patient with pure akinesia, 6 patients with multiple system atrophy, 1 patient with flunarizine induced parkinsonism, and 4 patients with unclassified parkinsonism. The MR images were obtained using a 1.5-T GE MR System. A spin-echo pulse sequence was used with a TE of 30 msec and 80 msec and a TR of 2000 msec. No signal abnormalities were seen in any patient with Parkinson's disease but 3 showed slightly decreased signal intensity of the putamen on T2-weighted sequences. Patients with diurnally fluctuating progressive dystonia and pure akinesia evidensed no abnormal findings. All six patients with multiple system atrophy demonstrated decreased signal intensity of the putamen, particularly along their lateral and posterior portions, and an enlarged substantia nigra. Atrophy of the pons and cerebellum was detected in all cases with multiple system atrophy. One case of flunarizine induced parkinsonism showed slightly decreased signal intensity of the putamen. Four cases of unclassified parkinsonism showed decreased signal in the putamen on T2-weighted sequences. Magnetic resonance imaging has the potential to become a useful diagnostic tool in the management of parkinsonism. (author).

  12. Migraine and magnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Younis, Samaira; Hougaard, Anders; Vestergaard, Mark B.

    2017-01-01

    Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation in the meth......Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation...... in the methodology and quality of the MRS migraine studies over time, some results were consistent and reproducible. 31P-MRS studies suggested reduced availability of neuronal energy and implied a mitochondrial dysfunction in the migraine brain. 1H-MRS studies reported interictal abnormalities in the excitatory...... and inhibitory neurotransmitters, glutamate and g-aminobutyric acid (GABA), suggesting persistent altered excitability in migraine patients. N-Acetylaspartate levels were decreased in migraine, probably due to a mitochondrial dysfunction and abnormal energy metabolism. The reported abnormalities may increase...

  13. Magnetic resonance imaging of chemistry.

    Science.gov (United States)

    Britton, Melanie M

    2010-11-01

    Magnetic resonance imaging (MRI) has long been recognized as one of the most important tools in medical diagnosis and research. However, MRI is also well placed to image chemical reactions and processes, determine the concentration of chemical species, and look at how chemistry couples with environmental factors, such as flow and heterogeneous media. This tutorial review will explain how magnetic resonance imaging works, reviewing its application in chemistry and its ability to directly visualise chemical processes. It will give information on what resolution and contrast are possible, and what chemical and physical parameters can be measured. It will provide examples of the use of MRI to study chemical systems, its application in chemical engineering and the identification of contrast agents for non-clinical applications. A number of studies are presented including investigation of chemical conversion and selectivity in fixed-bed reactors, temperature probes for catalyst pellets, ion mobility during tablet dissolution, solvent dynamics and ion transport in Nafion polymers and the formation of chemical waves and patterns.

  14. Magnetic fluid seals for DWDM filter manufacturing

    International Nuclear Information System (INIS)

    Li Zhixin

    2002-01-01

    Performance requirements of rotary magnetic fluid seals for thin film dense wavelength division multiplexing filter manufacturing are discussed. High speed, large diameter, tight tolerance for rotating accuracy and motion control are some of the technical challenges in this application. Analytical methods for studying these technical issues and experimental data are presented. Innovative design approaches are also discussed. It is shown that using the most advanced magnetic fluid technology and seal design technology, magnetic fluid seals can provide satisfactory performance in this challenging new application

  15. Magnetization of High Density Hadronic Fluid

    DEFF Research Database (Denmark)

    Bohr, Henrik; Providencia, Constanca; da Providencia, João

    2012-01-01

    In the present paper the magnetization of a high density relativistic fluid of elementary particles is studied. At very high densities, such as may be found in the interior of a neutron star, when the external magnetic field is gradually increased, the energy of the normal phase of the fluid...... in the particle fluid. For nuclear densities above 2 to 3 rho(0), where rho(0) is the equilibrium nuclear density, the resulting magnetic field turns out to be rather huge, of the order of 10(17) Gauss....

  16. Advances in mechanical detection of magnetic resonance

    International Nuclear Information System (INIS)

    Kuehn, Seppe; Hickman, Steven A.; Marohn, John A.

    2008-01-01

    The invention and initial demonstration of magnetic resonance force microscopy (MRFM) in the early 1990s launched a renaissance of mechanical approaches to detecting magnetic resonance. This article reviews progress made in MRFM in the last decade, including the demonstration of scanned probe detection of magnetic resonance (electron spin resonance, ferromagnetic resonance, and nuclear magnetic resonance) and the mechanical detection of electron spin resonance from a single spin. Force and force-gradient approaches to mechanical detection are reviewed and recent related work using attonewton sensitivity cantilevers to probe minute fluctuating electric fields near surfaces is discussed. Given recent progress, pushing MRFM to single proton sensitivity remains an exciting possibility. We will survey some practical and fundamental issues that must be resolved to meet this challenge.

  17. Magnetic resonance imaging: hazard, risk and safety

    International Nuclear Information System (INIS)

    Narayan, Pradeep; Suri, S.; Singh, P.

    2001-01-01

    The hazard and risk associated with magnetic resonance imaging is a matter of concern. In 1982, the Food and Drug Administration (FDA), USA issued guidelines to Hospital's Investigational Review Board (IRBs) in 'Guidelines for Evaluating Electromagnetic Exposure Risks for Trials of Clinical Nuclear Magnetic Resonance (NMR)'. In 1997, the Berufsgenossenschaft (BG), professional association for precision engineering and electronics of Germany, in their preliminary proposal for safety limits extended their concerns on static magnetic field. Owing to both time varying and static magnetic fields applied in Magnetic Resonance Imaging (MRI) this became of immediate concern to user community to assess the potential hazard and risk associated with the NMR system

  18. Assessment of magnetic fluid stability in non-homogeneous magnetic field of a single-tooth magnetic fluid sealer

    Energy Technology Data Exchange (ETDEWEB)

    Arefyev, I.M.; Demidenko, O.V.; Saikin, M.S.

    2017-06-01

    A special experimental stand has been developed and made to test magnetic fluid. It represents a single-tooth magnetic fluid sealer. The type of dependence of the pressure differential on magnetic fluid sealer operation time is used as a criterion to determine magnetic fluid stability and magnetic fluid sealer service life under such conditions. The siloxane-based magnetic fluid was used as the test sample. The colloidal stability as well as stability of the synthesized magnetic fluid in magnetic fields in static mode were determined. It has been found that the obtained magnetic fluid is stable in static mode and, consequently, can be used to conduct necessary tests on stand. Short-term and life tests on stand have shown that MF remains stable and efficient for at least 360 days of continuous utilization. - Highlights: • An experimental single-tooth magnetic fluid sealer has been developed and made. • The magnetic fluid based on siloxane liquid was used as the test sample. • Short-term and life tests of the magnetic fluid were conducted. • The magnetic fluid stability was determined by necessary tests on stand.

  19. Magnetic resonance imaging of Parkinsonism

    International Nuclear Information System (INIS)

    Nakamura, Yusaku; Takahashi, Mitsuo; Kitaguchi, Masataka; Akaneya, Yukio; Mitui, Yoshiyuki; Tanaka, Hisashi

    1991-01-01

    We studied eighteen patients affected by Parkinsonism with symptoms of tremor, bradykinesia, or rigidity using magnetic resonance imaging (MRI). Patients ranged in age from 34 to 80 years (mean 62.8±11.6 years), and the duration of their disease had been 3.8±3.2 years. MRI examinations were performed with Shimazu and Siemens superconducting magnets, operating at 0.5 and 1.5 T magnetic fields, respectively. Both T 1 - and T 2 -weighted spin echo (SE) pulse sequences were used. In eight patients (44.4%), MRI demonstrated bilateral multiple lacunar infarction of the basal ganglia. The most common abnormality identified was multiple, bilateral lacunar infarcts in the lateral portion of the putamen. The average size of the lacunar infarction of the putamen was less than half that of the entire putamen. Patients with multiple lacunar infarction were significantly older than the other patients and had lower Yahr's scores. The clinical symptoms of patients with bilateral multiple lacunar infarction of the basal ganglia were compatible with the diagnosis of arteriosclerotic Parkinsonism of akinetic rigid type. It has been suggested that multiple lacunar infarction of the basal ganglia may have led to Parkinsonism in these patients. (author)

  20. Nuclear magnetic resonance imaging method

    International Nuclear Information System (INIS)

    Johnson, G.; MacDonald, J.; Hutchison, S.; Eastwood, L.M.; Redpath, T.W.T.; Mallard, J.R.

    1984-01-01

    A method of deriving three dimensional image information from an object using nuclear magnetic resonance signals comprises subjecting the object to a continuous, static magnetic field and carrying out the following set of sequential steps: 1) exciting nuclear spins in a selected volume (90deg pulse); 2) applying non-aligned first, second and third gradients of the magnetic field; 3) causing the spins to rephase periodically by reversal of the first gradient to produce spin echoes, and applying pulses of the second gradient prior to every read-out of an echo signal from the object, to differently encode the spin in the second gradient direction for each read-out signal. The above steps 1-3 are then successively repeated with different values of gradient of the third gradient, there being a recovery interval between the repetition of successive sets of steps. Alternate echoes only are read out, the other echoes being time-reversed and ignored for convenience. The resulting signals are appropriately sampled, set out in an array and subjected to three dimensional Fourier transformation. (author)

  1. Magnetic resonance cisternography; Magnetresonanz-Zisternographie

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, U. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg-Saar (Germany)

    2018-02-15

    Conventional MRI can be insufficient to depict certain pathologies of the cerebrospinal fluid (CSF)-filled spaces. 3-D T2-weighted sequences and phase-contrast imaging have a high sensitivity for pathologies of the CSF-filled spaces, but are susceptible to artifacts in some cases. Magnetic resonance (MR) cisternography directly depicts the connection between CSF-filled spaces. (orig.) [German] Bei bestimmten Fragestellungen, die Pathologien des Liquorraums betreffen, kann die konventionelle MRT-Bildgebung an ihre Grenzen stossen. Duennschichtige 3-D-T2-Sequenzen und die Phasenkontrastbildgebung koennen die Liquorraeume und den Liquorfluss mit hoher Aufloesung darstellen, sind aber zum Teil anfaellig fuer Artefakte. Die Magnetresonanz(MR)-Zisternographie erlaubt die genaue Darstellung des Liquorraums und stellt Verbindungen einzelner Kompartimente direkt dar. (orig.)

  2. The magnetic fluid for heat transfer applications

    International Nuclear Information System (INIS)

    Nakatsuka, K.; Jeyadevan, B.; Neveu, S.; Koganezawa, H.

    2002-01-01

    Real-time visual observation of boiling water-based and ionic magnetic fluids (MFs) and heat transfer characteristics in heat pipe using ionic MF stabilized by citrate ions (JC-1) as working liquid are reported. Irrespective of the presence or absence of magnetic field water-based MF degraded during boiling. However, the degradation of JC-1 was avoided by heating the fluid in magnetic field. Furthermore, the heat transfer capacity of JC-1 heat pipe under applied magnetic field was enhanced over the no field case

  3. Transition metal nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Pregosin, P.S.

    1991-01-01

    Transition metal NMR spectroscopy has progressed enormously in recent years. New methods, and specifically solid-state methods and new pulse sequences, have allowed access to data from nuclei with relatively low receptivities with the result that chemists have begun to consider old and new problems, previously unapproachable. Moreover, theory, computational science in particular, now permits the calculation of not just 13 C, 15 N and other light nuclei chemical shifts, but heavy main-group element and transition metals as well. These two points, combined with increasing access to high field pulsed spectrometer has produced a wealth of new data on the NMR transition metals. A new series of articles concerned with measuring, understanding and using the nuclear magnetic resonance spectra of the metals of Group 3-12 is presented. (author)

  4. Gaucher's disease: Magnetic resonance findings

    International Nuclear Information System (INIS)

    Roca, M.; Gomez-Pereda, R.; Blasco, A.; Ros, L.

    1996-01-01

    The objective is to assess the role of magnetic resonance (MR) in determining the initial extension of Gaucher's disease and its complications. A retrospective study of eight patients diagnosed as having Gaucher's disease was carried out using MR. The study focused on pelvis, hip, femur, spine, liver parenchyma and splenic parenchyma. Infiltration of the cancellous portion of the vertebral bodies was observed in all but one of the patients. Three patients presented small hemangiomas in dorsal and lumbar vertebral bodies. Pelvic bone involvement was homogeneous in four cases and spotty in two, while the pelvic marrow was normal in the two patients with no vertebral infiltration. A vascular necrosis of the femoral head was detected in two cases. MR is very useful in determining the initial extension, in the early diagnosis of complications and in managing the posttreatment marrow response to assess the therapeutic efficacy. 16 refs

  5. Fetal abdominal magnetic resonance imaging

    International Nuclear Information System (INIS)

    Brugger, Peter C.; Prayer, Daniela

    2006-01-01

    This review deals with the in vivo magnetic resonance imaging (MRI) appearance of the human fetal abdomen. Imaging findings are correlated with current knowledge of human fetal anatomy and physiology, which are crucial to understand and interpret fetal abdominal MRI scans. As fetal MRI covers a period of more than 20 weeks, which is characterized not only by organ growth, but also by changes and maturation of organ function, a different MR appearance of the fetal abdomen results. This not only applies to the fetal intestines, but also to the fetal liver, spleen, and adrenal glands. Choosing the appropriate sequences, various aspects of age-related and organ-specific function can be visualized with fetal MRI, as these are mirrored by changes in signal intensities. Knowledge of normal development is essential to delineate normal from pathological findings in the respective developmental stages

  6. Fetal abdominal magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, Peter C. [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University of Vienna, Waehringerstrasse 13, 1090 Vienna (Austria)]. E-mail: peter.brugger@meduniwien.ac.at; Prayer, Daniela [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria)

    2006-02-15

    This review deals with the in vivo magnetic resonance imaging (MRI) appearance of the human fetal abdomen. Imaging findings are correlated with current knowledge of human fetal anatomy and physiology, which are crucial to understand and interpret fetal abdominal MRI scans. As fetal MRI covers a period of more than 20 weeks, which is characterized not only by organ growth, but also by changes and maturation of organ function, a different MR appearance of the fetal abdomen results. This not only applies to the fetal intestines, but also to the fetal liver, spleen, and adrenal glands. Choosing the appropriate sequences, various aspects of age-related and organ-specific function can be visualized with fetal MRI, as these are mirrored by changes in signal intensities. Knowledge of normal development is essential to delineate normal from pathological findings in the respective developmental stages.

  7. Magnetic resonance imaging in neuroradiology

    International Nuclear Information System (INIS)

    Voigt, K.; Lotx, J.W.

    1990-01-01

    Magnetic resonance imaging (MRI) is now accepted as an effective method of investigating a wide range of disorders, especially of the brain and spine. A short introduction on image contrast in MRI is given and the advantages and disadvantages for the different diseases of the brain is discussed. Excellent soft-tissue contrast, multiplanar imaging capabilities and lack of ionising radiation are conspicuous advantages, and it is now established as the investigation of choice in a large number of clinical conditions, especially when the central nervous system is involved. However, it remains only one of a series of imaging modalities. A confident provisional clinical diagnosis is essential for establishing an imaging protocol and the intention should always be to reach a definitive diagnosis in the least invasive and most cost-effective way. 7 figs., 19 refs

  8. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1988-01-01

    Magnetic resonance imaging offers new possibilities in investigation of the prostate gland. Current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be useful in the staging of carcinoma of the prostate....

  9. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1987-01-01

    Magnetic resonance imaging offers new possibilities in the investigation of the prostate. The current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be of value in the staging of carcinoma of the prostate....

  10. Single voxel magnetic resonance spectroscopy in distinguishing ...

    African Journals Online (AJOL)

    Objective: Assess diagnostic utility of combined magnetic resonance imaging and magnetic resonance spectroscopy (MRI, MRS) in differentiating focal neoplastic lesions from focal non- neoplastic (infective or degenerative) brain lesions. Design: Descriptive, analytical - prospective study. Setting: The Aga Khan University ...

  11. Magnetic resonance imaging of radiation optic neuropathy

    International Nuclear Information System (INIS)

    Zimmerman, C.F.; Schatz, N.J.; Glaser, J.S.

    1990-01-01

    Three patients with delayed radiation optic neuropathy after radiation therapy for parasellar neoplasms underwent magnetic resonance imaging. The affected optic nerves and chiasms showed enlargement and focal gadopentetate dimeglumine enhancement. The magnetic resonance imaging technique effectively detected and defined anterior visual pathway changes of radionecrosis and excluded the clinical possibility of visual loss because of tumor recurrence

  12. Magnetic resonance: discovery, investigations, and applications

    International Nuclear Information System (INIS)

    Kessenikh, Aleksandr V

    2009-01-01

    The history of the development of the theoretical ideas and experimental methods of magnetic resonance, as well as the applications of these methods in modern natural science, technology, and medicine, are outlined, with allowance for the contribution of Russian researchers. An assessment of some promising trends of studies and applications of magnetic resonance is given. (from the history of physics)

  13. Contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Karadjian, V.

    1987-01-01

    The origine of nuclear magnetic resonance signal is reminded and different ways for contrast enhancement in magnetic resonance imaging are presented, especially, modifications of tissus relaxation times. Investigations have focused on development of agents incorporating either paramagnetic ions or stable free radicals. Pharmacological and toxicological aspects are developed. The diagnostic potential of these substances is illustrated by the example of gadolinium complexes [fr

  14. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA ...

  15. Magnetic nanofluids and magnetic composite fluids in rotating seal systems

    International Nuclear Information System (INIS)

    Borbath, T; Borbath, I; Boros, T; Bica, D; Vekas, L; Potencz, I

    2010-01-01

    Recent results are presented concerning the development of magnetofluidic leakage-free rotating seals for vacuum and high pressure gases, evidencing significant advantages compared to mechanical seals. The micro-pilot scale production of various types of magnetizable sealing fluids is shortly reviewed, in particular the main steps of the chemical synthesis of magnetic nanofluids and magnetic composite fluids with light hydrocarbon, mineral oil and synthetic oil carrier liquids. The behavior of different types of magnetizable fluids in the rotating sealing systems is analyzed. Design concepts, some constructive details and testing procedures of magnetofluidic rotating seals are presented such as the testing equipment. The main characteristics of several magnetofluidic sealing systems and their applications will be presented: vacuum deposition systems and liquefied gas pumps applications, mechanical and magnetic nanofluid combined seals, gas valves up to 40 bar equipped by rotating seal with magnetic nanofluids and magnetic composite fluids.

  16. Multidimensionally encoded magnetic resonance imaging.

    Science.gov (United States)

    Lin, Fa-Hsuan

    2013-07-01

    Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image reconstruction performance. Here, we propose the multidimensionally encoded (MDE) MRI to map a q-dimensional object onto a p-dimensional encoding space where p > q. MDE MRI is a theoretical framework linking imaging strategies using linear and nonlinear SEMs. Using a system of eight surface SEM coils with an eight-channel radiofrequency coil array, we demonstrate the five-dimensional MDE MRI for a two-dimensional object as a further generalization of PatLoc imaging and O-space imaging. We also present a method of optimizing spatial bases in MDE MRI. Results show that MDE MRI with a higher dimensional encoding space can reconstruct images more efficiently and with a smaller reconstruction error when the k-space sampling distribution and the number of samples are controlled. Copyright © 2012 Wiley Periodicals, Inc.

  17. Magnetic fluid bridge in a non-uniform magnetic field

    International Nuclear Information System (INIS)

    Pelevina, D.A.; Naletova, V.A.; Turkov, V.A.

    2017-01-01

    The shape of a magnetic fluid bridge between a horizontal ferrite rod of circular cross-section and a horizontal plate above the rod in a vertical applied uniform magnetic field is studied. Various static shapes of the bridges are obtained theoretically and experimentally for the same magnetic field value. Abrupt changes and the hysteresis of the bridge shape in alternating magnetic fields are observed experimentally. - Highlights: • Magnetic fluid bridge between rod and horizontal plate in magnetic field is studied. • Magnetic field is created by a ferrite rod in a uniform vertical magnetic field. • Various static bridge shapes for fixed field are obtained in theory and experiment. • A good agreement of experimental and theoretical results is obtained. • Hysteresis of the bridge shape in alternating field is observed experimentally.

  18. Mechanics of magnetic fluid column in strong magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Polunin, V.M.; Ryapolov, P.A., E-mail: r-piter@yandex.ru; Platonov, V.B.

    2017-06-01

    Elastic-and magnetic properties of magnetic fluid confined by ponderomotive force in a tube fixed in horizontal position are considered. The system is placed in a strong magnetic field under the influence of external static and dynamic perturbations. An experimental setup has been developed. A theoretical basis of the processes of magnetic colloid elastic deformation has been proposed. The values of the static ponderomotive elasticity coefficient and the elasticity coefficient under dynamic action are experimentally determined. The calculations of the saturation magnetization for two magnetic fluid samples, carried out according to the equation containing the dynamic elasticity coefficient, are in good agreement with the experimental magnetization curve. The described method is of interest when studying magnetophoresis and aggregation of nanoparticles in magnetic colloids.

  19. Magnetic fluid bridge in a non-uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Pelevina, D.A., E-mail: pelevina.daria@gmail.com; Naletova, V.A.; Turkov, V.A.

    2017-06-01

    The shape of a magnetic fluid bridge between a horizontal ferrite rod of circular cross-section and a horizontal plate above the rod in a vertical applied uniform magnetic field is studied. Various static shapes of the bridges are obtained theoretically and experimentally for the same magnetic field value. Abrupt changes and the hysteresis of the bridge shape in alternating magnetic fields are observed experimentally. - Highlights: • Magnetic fluid bridge between rod and horizontal plate in magnetic field is studied. • Magnetic field is created by a ferrite rod in a uniform vertical magnetic field. • Various static bridge shapes for fixed field are obtained in theory and experiment. • A good agreement of experimental and theoretical results is obtained. • Hysteresis of the bridge shape in alternating field is observed experimentally.

  20. Dissipative charged fluid in a magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Abbasi, Navid; Davody, Ali, E-mail: davody.phy@gmail.com

    2016-05-10

    We study the collective excitations in a dissipative charged fluid at zero chemical potential when an external magnetic field is present. While in the absence of magnetic field, four collective excitations appear in the fluid, we find five hydrodynamic modes here. This implies that the magnetic field splits the degeneracy between the transverse shear modes. Using linear response theory, we then compute the retarded response functions. In particular, it turns out that the correlation between charge and the energy fluctuations will no longer vanish, even at zero chemical potential. By use of the response functions, we also derive the relevant Kubo formulas for the transport coefficients.

  1. Magnetic fluids stabilized by polypropylene glycol

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, A.V., E-mail: lav@icmm.r [Institute of Continuous Media Mechanics, UB RAS, Academic Korolev Str. 1, Perm 614013 (Russian Federation); Lysenko, S.N. [Institute of Technical Chemistry, UB RAS, Academic Korolev Str. 3, Perm 614013 (Russian Federation)

    2011-05-15

    A series of samples of magnetic fluids stabilized with low-molecular weight polypropylene glycol (PPG) of different molecular masses were synthesized. The use of PPG allowed the maximum extension of the carrier fluid range to include ethyl- and butyl-acetate, ethanol, butanol, acetone, carbon tetrachloride, toluene, kerosene and PPG itself. Magnetic and rheological properties of the samples were investigated. Based on the results of investigation it has been concluded that magnetic nanoparticles are covered by a monolayer of surfactant molecules. At low temperatures the propanol-based sample preserves fluidity up to -115 {sup o}C. Measurement of critical temperatures of other base fluids showed that alcohols are the best carrier medium. Coagulation stability of the ethanol-based ferrocolloid with respect to water and kerosene was explored. It has been found that kerosene, whose fraction by weight exceeds 22.5%, does not mix with the colloid. This effect can be used to produce magneto-controllable extractors of ethyl alcohol. Under the action of water the colloid coagulates, which allows one to substitute the carrier fluid and to separate the colloid into fractions. - Research highlights: PPG stabilizes the magnetic particles in the polar and non-polar media. The minimum operating temperature reaches -115 {sup o}C. Alcohols are the best environment for PPG-stabilized particles. PPG magnetic fluids can be used as magnetic extractors of alcohol. PPG MF can be divided into fractions by partial coagulation with water.

  2. Force detection of nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Rugar, D.; Zueger, O.; Hoen, S.; Yannoni, C.S.; Vieth, H.M.; Kendrick, R.D.

    1994-01-01

    Micromechanical sensing of magnetic force was used to detect nuclear magnetic resonance with exceptional sensitivity and spatial resolution. With a 900 angstrom thick silicon nitride cantilever capable of detecting subfemtonewton forces, a single shot sensitivity of 1.6 x 10 13 protons was achieved for an ammonium nitrate sample mounted on the cantilever. A nearby millimeter-size iron particle produced a 600 tesla per meter magnetic field gradient, resulting in a spatial resolution of 2.6 micrometers in one dimension. These results suggest that magnetic force sensing is a viable approach for enhancing the sensitivity and spatial resolution of nuclear magnetic resonance microimaging

  3. Magnetic resonance elastometry using a single-sided permanent magnet

    International Nuclear Information System (INIS)

    Tan, Carl S; Marble, Andrew E; Ono, Yuu

    2012-01-01

    In this paper, we describe a magnetic resonance method of measuring material elasticity using a single-sided magnet with a permanent static field gradient. This method encodes sample velocity in a reciprocal space using Hahn spin-echoes with variable timing. The experimental results show a strong correlation between magnetic resonance signal attenuation and elasticity when an oscillating force is applied on the sample. This relationship in turn provides us with information about the displacement velocity experienced by the sample, which is inversely proportional to Young's modulus. The proposed method shows promise in offering a portable and cost-effective magnetic resonance elastography system. (paper)

  4. Artifacts in Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Krupa, Katarzyna; Bekiesińska-Figatowska, Monika

    2015-01-01

    Artifacts in magnetic resonance imaging and foreign bodies within the patient’s body may be confused with a pathology or may reduce the quality of examinations. Radiologists are frequently not informed about the medical history of patients and face postoperative/other images they are not familiar with. A gallery of such images was presented in this manuscript. A truncation artifact in the spinal cord could be misinterpreted as a syrinx. Motion artifacts caused by breathing, cardiac movement, CSF pulsation/blood flow create a ghost artifact which can be reduced by patient immobilization, or cardiac/respiratory gating. Aliasing artifacts can be eliminated by increasing the field of view. An artificially hyperintense signal on FLAIR images can result from magnetic susceptibility artifacts, CSF/vascular pulsation, motion, but can also be found in patients undergoing MRI examinations while receiving supplemental oxygen. Metallic and other foreign bodies which may be found on and in patients’ bodies are the main group of artifacts and these are the focus of this study: e.g. make-up, tattoos, hairbands, clothes, endovascular embolization, prostheses, surgical clips, intraorbital and other medical implants, etc. Knowledge of different types of artifacts and their origin, and of possible foreign bodies is necessary to eliminate them or to reduce their negative influence on MR images by adjusting acquisition parameters. It is also necessary to take them into consideration when interpreting the images. Some proposals of reducing artifacts have been mentioned. Describing in detail the procedures to avoid or limit the artifacts would go beyond the scope of this paper but technical ways to reduce them can be found in the cited literature

  5. NON-CONTRAST MAGNETIC RESONANCE UROGRAPHY

    Directory of Open Access Journals (Sweden)

    Arpita C

    2016-07-01

    Full Text Available BACKGROUND AND PURPOSE Magnetic Resonance (MR urography with its optimal contrast resolution and lack of ionizing radiation provides a comprehensive examination of the entire urinary tract noninvasively. MR urography is clinically useful in the evaluation of suspected urinary tract obstruction, haematuria, congenital anomalies, and surgically altered anatomy. It is particularly useful in cases of where there is contraindication of ionizing radiation and in paediatric and pregnant patients. The common MR urographic techniques are: Static-fluid MR urography and excretory MR urography. Static-fluid MR urography uses of heavily T2-weighted sequences to image the urinary tract as a static collection of fluid, can be repeated sequentially (Cine MR urography to better demonstrate the ureters in their entirety and to confirm the presence of fixed stenoses. Excretory MR urography is performed during the excretory phase of enhancement after the intravenous administration of gadolinium-based contrast material; thus, the patient must have sufficient renal function to allow the excretion. Static-fluid and excretory MR urography can be combined with conventional MR imaging for comprehensive evaluation of the urinary tract. The limitations are limited availability, high cost, relatively long examination time, low spatial resolution compared to IVU (Intravenous Urogram and CT Urography; sensitivity to motion (breathing and ureteral peristalsis inherent contraindications like patients with pacemakers, claustrophobia, and relative insensitivity for calcification and ureteric calculi. In this article, an attempt has been made to demonstrate the potential of static-fluid MRU to demonstrate a spectrum of urologic pathology involving the kidneys, ureters, and bladder while discussing the limitations. METHODS Thirty patients with urinary tract abnormalities were evaluated with MR urography performed between May 2014 to April 2016 using routine MR sequences and

  6. Magnetic resonance in obstructive jaundice

    International Nuclear Information System (INIS)

    Gupta, R.K.; Jena, A.; Khushu, S.; Kakar, A.K.; Mishra, P.K.

    1989-01-01

    Twelve cases of obstructive jaundice in whom ultrasound failed to demonstrate the site and/or the cause of obstruction of the biliary tract were examined with magnetic resonance imaging (MRI), correctly diagnosing the site and cause of obstruction in 10 of 12 surgically proven cases. In one case of cholangiocarcinoma, the site of obstruction was well shown on MR but a definite cause could not be ascertained. In another patient who developed intermittent jaundice following surgery for choledochal cyst, MR demonstrated a solitary stone in the common hepatic duct. Surgical confirmation could not be achieved as the patient was lost to follow up. There were 6 cases of choledocholithiasis, 3 cases of gall bladder carcinoma and one case each of pancreatic adenocarcinoma and cholangiocarcinoma. It is believed that MRI will provide obstructive jaundice and will be able to minimize the use of percutaneous transhepatic cholangiography (PTC) and endoscopic retrograde cholangiopancreatography (ERCP) in view of its ability to perform multiplanar imaging in multiple sequences. 11 refs., figs., 1 tab

  7. Low rank magnetic resonance fingerprinting.

    Science.gov (United States)

    Mazor, Gal; Weizman, Lior; Tal, Assaf; Eldar, Yonina C

    2016-08-01

    Magnetic Resonance Fingerprinting (MRF) is a relatively new approach that provides quantitative MRI using randomized acquisition. Extraction of physical quantitative tissue values is preformed off-line, based on acquisition with varying parameters and a dictionary generated according to the Bloch equations. MRF uses hundreds of radio frequency (RF) excitation pulses for acquisition, and therefore high under-sampling ratio in the sampling domain (k-space) is required. This under-sampling causes spatial artifacts that hamper the ability to accurately estimate the quantitative tissue values. In this work, we introduce a new approach for quantitative MRI using MRF, called Low Rank MRF. We exploit the low rank property of the temporal domain, on top of the well-known sparsity of the MRF signal in the generated dictionary domain. We present an iterative scheme that consists of a gradient step followed by a low rank projection using the singular value decomposition. Experiments on real MRI data demonstrate superior results compared to conventional implementation of compressed sensing for MRF at 15% sampling ratio.

  8. Presurgical functional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Stippich, C.

    2010-01-01

    Functional magnetic resonance imaging (fMRI) is an important and novel neuroimaging modality for patients with brain tumors. By non-invasive measurement, localization and lateralization of brain activiation, most importantly of motor and speech function, fMRI facilitates the selection of the most appropriate and sparing treatment and function-preserving surgery. Prerequisites for the diagnostic use of fMRI are the application of dedicated clinical imaging protocols and standardization of the respective imaging procedures. The combination with diffusion tensor imaging (DTI) also enables tracking and visualization of important fiber bundles such as the pyramidal tract and the arcuate fascicle. These multimodal MR data can be implemented in computer systems for functional neuronavigation or radiation treatment. The practicability, accuracy and reliability of presurgical fMRI have been validated by large numbers of published data. However, fMRI cannot be considered as a fully established modality of diagnostic neuroimaging due to the lack of guidelines of the responsible medical associations as well as the lack of medical certification of important hardware and software components. This article reviews the current research in the field and provides practical information relevant for presurgical fMRI. (orig.) [de

  9. Endometrial cancer: magnetic resonance imaging.

    Science.gov (United States)

    Manfredi, R; Gui, B; Maresca, G; Fanfani, F; Bonomo, L

    2005-01-01

    Carcinoma of the endometrium is the most common invasive gynecologic malignancy of the female genital tract. Clinically, patients with endometrial carcinoma present with abnormal uterine bleeding. The role of magnetic resonance imaging (MRI) in endometrial carcinoma is disease staging and treatment planning. MRI has been shown to be the most valuable imaging mod-ality in this task, compared with endovaginal ultrasound and computed tomography, because of its intrinsic contrast resolution and multiplanar capability. MRI protocol includes axial T1-weighted images; axial, sagittal, and coronal T2-weighted images; and dynamic gadolinium-enhanced T1-weighted imaging. MR examination is usually performed in the supine position with a phased array multicoil using a four-coil configuration. Endometrial carcinoma is isointense with the normal endometrium and myometrium on noncontrast T1-weighted images and has a variable appearance on T2-weighted images demonstrating heterogeneous signal intensity. The appearance of noninvasive endometrial carcinoma on MRI is characterized by a normal or thickened endometrium, with an intact junctional zone and a sharp tumor-myometrium interface. Invasive endometrial carcinoma is characterized disruption or irregularity of the junctional zone by intermediate signal intensity mass on T2-weighted images. Invasion of the cervical stroma is diagnosed when the low signal intensity cervical stroma is disrupted by the higher signal intensity endometrial carcinoma. MRI in endometrial carcinoma performs better than other imaging modalities in disease staging and treatment planning. Further, the accuracy and the cost of MRI are equivalent to those of surgical staging.

  10. Endovascular interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bartels, L W; Bakker, C J G

    2003-01-01

    Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed. (topical review)

  11. Magnetic resonance imaging and neurolupus

    International Nuclear Information System (INIS)

    Schott, A.M.; Colson, F.; Tebib, J.; Noel, E.; Bouvier, M.

    1990-01-01

    Magnetic resonance imaging (MRI) was assessed in the management of neuropsychiatric manifestations occurring in 6 SLE patients. The MRI scans were normal in 3 cases and was associated with remission of the symptoms except for a patient who experienced a chorea at the time of the examination. Abnormal MRI scans always revealed more lesions than CT scan. 2 different patterns of abnormalities seem to correspond to 2 specific disorders. In 2 patients with clinical presentation suggesting a cortical ischemia by vascular thrombosis, both MRI scans showed areas of abnormal high signal intensities located in the subcortical white matter. In one last patient, MRI scan revealed multiple focal areas of high signal intensities (on T 1 weighter scans) disseminated not only in the deep white matter but also in the gray one. These lesions could be depend upon demyelinisation which may occur by a local vascular process. This serie confirms the interest of MRI in the management of SLE brain involvement as well as it points out some problem of interpretation. This suggest further comparative studies especially at the real onset and during the course of neuro-psychiatric manifestations. At last, the coronal sections may be more informative for the diagnosis and patholophysiology than the horizontal ones [fr

  12. Magnetic resonance in multiple sclerosis

    International Nuclear Information System (INIS)

    Scotti, G.; Caputo, D.; Cazzullo, C.L.

    1986-01-01

    Magnetic Resonance Imaging was performed in more than 200 patients with clinical suspicion or knowledge of Multiple Sclerosis. One hundred and forty-seven (60 males and 87 females) had MR evidence of multiple sclerosis lesions. The MR signal of demyelinating plaques characteristically has prolonged T1 and T2 relaxation times and the T2-weighted spin-echo sequences are generally superior to the T1-weighted images because the lesions are better visualized as areas of increased signal intensity. MR is also able to detect plaques in the brainstem, cerebellum and within the cervical spinal cord. MR appears to be an important, non-invasive method for the diagnosis of Multiple Sclerosis and has proven to be diagnostically superior to CT, evoked potentials (EP) and CSF examination. In a selected group of 30 patients, with the whole battery of the relevant MS studies, MR was positive in 100%, CT in 33,3%, EP in 56% and CSF examination in 60%. In patients clinically presenting only with signs of spinal cord involvement or optic neuritis or when the clinical presentation is uncertain MR has proven to be a very useful diagnostic tool for diagnosis of MS by demonstrating unsuspected lesions in the cerebral hemispheres. (orig.)

  13. Myositis ossificans: magnetic resonance images

    International Nuclear Information System (INIS)

    Dosda, R.; Marti-Bonmati, L.; Concepcion, L.; Galant, J.

    1999-01-01

    Myositis ossificans is characterized by a benign, self-limiting, ossifying mass of the white tissue. In the present report, we describe the magnetic resonance (MR) images in three cases of myositis ossificans in pediatric patients, correlating the MR findings with those obtained with other radiological studies. The lesions were detected in three patients, two boys and one girl, ranging in age between 10 and 14 years. The nature of the lesion was confirmed histologically in all three cases. The MR images were obtained using superconductive units at 0.5 Teslas, with T1 and T2-weighted spin-echo and STIR sequences. In two patients, gadolinium-enhanced T1-weighted images were also obtained. As in any process of maturation, the proliferation/maturation ratio depends on the moment in the course of the lesion, which affects its MR features,. In acute phases, the soft tissue mass with an intraosseous, perilesional adematous reaction predominates, while annular calcification and lesser edema are characteristic of subacute episode. Myositis ossificans is very rare in children. The inflammatory response may present a radiological pattern difficult to distinguish from that of aggressive tumor or infection, especially in the acute phase. (Author) 7 refs

  14. Cardiovascular magnetic resonance in congenital heart disease

    International Nuclear Information System (INIS)

    Cazacu, A.; Ciubotaru, A.

    2010-01-01

    The increasing prevalence of congenital heart disease can be attributed to major improvements in diagnosis and treatment. Cardiovascular magnetic resonance imaging plays an important role in the clinical management strategy of patients with congenital heart disease. The development of new cardiovascular magnetic resonance (CMR) techniques allows comprehensive assessment of complex cardiac anatomy and function and provides information about the long-term residual post-operative lesions and complications of surgery. It overcomes many of the limitations of echocardiography and cardiac catheterization. This review evaluates the role of cardiovascular magnetic resonance imaging modality in the management of subject with congenital heart disease (CHD). (authors)

  15. Functional magnetic resonance imaging by visual stimulation

    International Nuclear Information System (INIS)

    Nishimura, Yukiko; Negoro, Kiyoshi; Morimatsu, Mitsunori; Hashida, Masahiro

    1996-01-01

    We evaluated functional magnetic resonance images obtained in 8 healthy subjects in response to visual stimulation using a conventional clinical magnetic resonance imaging system with multi-slice spin-echo echo planar imaging. Activation in the visual cortex was clearly demonstrated by the multi-slice experiment with a task-related change in signal intensity. In addition to the primary visual cortex, other areas were also activated by a complicated visual task. Multi-slice spin-echo echo planar imaging offers high temporal resolution and allows the three-dimensional analysis of brain function. Functional magnetic resonance imaging provides a useful noninvasive method of mapping brain function. (author)

  16. NMR magnetic field controller for pulsed nuclear magnetic resonance experiments

    International Nuclear Information System (INIS)

    Scheler, G.; Anacker, M.

    1975-01-01

    A nuclear magnetic resonance controller for magnetic fields, which can also be used for pulsed NMR investigations, is described. A longtime stability of 10 -7 is achieved. The control signal is generated by a modified time sharing circuit with resonance at the first side band of the 2 H signal. An exact calibration of the magnetic field is achieved by the variation of the H 1 - or of the time-sharing frequency. (author)

  17. A Magnetic Resonance Measurement Technique for Rapidly Switched Gradient Magnetic Fields in a Magnetic Resonance Tomograph

    Directory of Open Access Journals (Sweden)

    K. Bartušek

    2003-01-01

    Full Text Available This paper describes a method for measuring of the gradient magnetic field in Nuclear Magnetic Resonance (NMR tomography, which is one of the modern medical diagnostic methods. A very important prerequisite for high quality imaging is a gradient magnetic field in the instrument with exactly defined properties. Nuclear magnetic resonance enables us to measure the pulse gradient magnetic field characteristics with high accuracy. These interesting precise methods were designed, realised, and tested at the Institute of Scientific Instruments (ISI of the Academy of Sciences of the Czech Republic. The first of them was the Instantaneous Frequency (IF method, which was developed into the Instantaneous Frequency of Spin Echo (IFSE and the Instantaneous Frequency of Spin Echo Series (IFSES methods. The above named methods are described in this paper and their a comparison is also presented.

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... tumors stroke infections developmental anomalies hydrocephalus — dilatation of fluid spaces within the brain (ventricles) causes of epilepsy ( ... may not always distinguish between cancer tissue and fluid, known as edema . MRI typically costs more and ...

  19. GEOCHEMICAL CONTROLS ON NUCLEAR MAGNETIC RESONANCE MEASUREMENTS

    International Nuclear Information System (INIS)

    Knight, Rosemary

    2008-01-01

    Proton nuclear magnetic resonance (NMR) is used in the Earth Sciences as a means of obtaining information about the molecular-scale environment of fluids in porous geological materials. Laboratory experiments were conducted to advance our fundamental understanding of the link between the NMR response and the geochemical properties of geological materials. In the first part of this research project, we studied the impact of both the surface-area-to-volume ratio (S/V) of the pore space and the surface relaxivity on the NMR response of fluids in sand-clay mixtures. This study highlighted the way in which these two parameters control our ability to use NMR measurements to detect and quantify fluid saturation in multiphase saturated systems. The second part of the project was designed to explore the way in which the mineralogic form of iron, as opposed to simply the concentration of iron, affects the surface relaxation rate and, more generally, the NMR response of porous materials. We found that the magnitude of the surface relaxation rate was different for the various iron-oxide minerals because of changes in both the surface-area-to-volume ratio of the pore space, and the surface relaxivity. Of particular significance from this study was the finding of an anomalously large surface relaxivity of magnetite compared to that of the other iron minerals. Differences in the NMR response of iron minerals were seen in column experiments during the reaction of ferrihydrite-coated quartz sand with aqueous Fe(II) solutions to form goethite, lepidocrocite and magnetite; indicating the potential use of NMR as a means of monitoring geochemical reactions. The final part of the research project investigated the impact of heterogeneity, at the pore-scale, on the NMR response. This work highlighted the way in which the geochemistry, by controlling the surface relaxivity, has a significant impact on the link between NMR data and the microgeometry of the pore space.

  20. Reducing Field Distortion in Magnetic Resonance Imaging

    Science.gov (United States)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2010-01-01

    A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

  1. Pocket atlas of cranial magnetic resonance imaging

    International Nuclear Information System (INIS)

    Haughton, V.M.; Daniels, D.L.

    1986-01-01

    This atlas illustrates normal cerebral anatomy in magnetic resonance images. From their studies in cerebral anatomy utilizing cryomicrotome and other techniques, the authors selected more than 100 high-resolution images that represent the most clinically useful scans

  2. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by Image/Video Gallery Your ... Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot ...

  3. Fifty years of nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Martinez Valderrama, Juan Crisostomo

    1997-01-01

    Short information about the main developments of nuclear magnetic resonance during their fifty existence years is presented. Beside two examples of application (HETCOR and INADEQUATE) to the structural determination of organic compounds are described

  4. Principles of nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Pykett, I.L.; Newhouse, J.H.; Buonanno, F.S.; Brady, T.J.; Goldman, M.R.; Kistler, J.P.; Pohost, G.M.

    1982-01-01

    The physical principles which underlie the phenomenon of nuclear magnetic resonance (NMR) are presented in this primer. The major scanning methods are reviewed, and the principles of technique are discussed. A glossary of NMR terms is included

  5. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive test ... of the major blood vessels throughout your body. It may be performed with or without contrast material ...

  6. The role of magnetic resonance cholangiopancreatography and ...

    African Journals Online (AJOL)

    ) is accepted as the gold standard, there is a place for magnetic resonance cholangiopancreatography (MRCP) and diffusion-weighted imaging (DWI) in the diagnosis of obstructive biliary disorders. Aim: To compare the findings of MRCP with ...

  7. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  8. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... mild sedative prior to the examination. For more information about Magnetic Resonance Angiography of MRA or any ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  9. Chronic liver disease: evaluation by magnetic resonance

    International Nuclear Information System (INIS)

    Stark, D.D.; Goldberg, H.I.; Moss, A.A.; Bass, N.M.

    1984-01-01

    Magnetic resonance (MR) imaging distinguished hepatitis from fatty liver and cirrhosis in a woman with a history of alcohol abuse. Anatomic and physiologic manifestations of portal hypertension were also demonstrated by MR

  10. Nuclear Magnetic Resonance Trackbed Moisture Sensor System

    Science.gov (United States)

    2018-02-01

    In this initial phase, conducted from March 2015 through December 2016, Vista Clara and its subcontractor Zetica Rail successfully developed and tested a man-portable, non-invasive spot-check nuclear magnetic resonance (NMR) moisture sensor that dire...

  11. Can magnetic resonance imaging differentiate undifferentiated arthritis?

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Duer, Anne; Hørslev-Petersen, K

    2005-01-01

    A high sensitivity for the detection of inflammatory and destructive changes in inflammatory joint diseases makes magnetic resonance imaging potentially useful for assigning specific diagnoses, such as rheumatoid arthritis and psoriatic arthritis in arthritides, that remain undifferentiated after...... conventional clinical, biochemical and radiographic examinations. With recent data as the starting point, the present paper describes the current knowledge on magnetic resonance imaging in the differential diagnosis of undifferentiated arthritis....

  12. Nuclear magnetic resonance spectroscopy and imaging

    International Nuclear Information System (INIS)

    Jiang Weiping; Wang Qi; Zhou Xin

    2013-01-01

    This paper briefly introduces the basic principle of nuclear magnetic resonance (NMR). Protein's structures and functions and dynamics studied by liquid NMR are elaborated; methods for enhancing the resolution of solid state NMR and its applications are discussed; the principle of magnetic resonance imaging (MRI) is interpreted, and applications in different aspects are reviewed. Finally, the progress of NMR is commented. (authors)

  13. Concepts and indications of abdominal magnetic resonance

    International Nuclear Information System (INIS)

    Murillo Viera, Wendy

    2012-01-01

    A literature review and conceptualization was performed of the main indications of magnetic resonance studies of the abdomen and the characteristic findings for each sequence, according to organ and pathology. The radiologist has had in mind main indications for magnetic resonance studies of the abdomen, with the purpose to guide the clinician in the choice of imaging modality that works best for the patient at diagnosis [es

  14. Magnetic resonance imaging of muscle tears

    International Nuclear Information System (INIS)

    De Smet, A.A.; Fisher, D.R.; Heiner, J.P.; Keene, J.S.

    1990-01-01

    Magnetic resonance scans were obtained on 17 patients with acute, subacute, or chronic muscle tears. These patients presented with complaints of persistent pain or a palpable mass. Magnetic resonance findings were characterized according to alterations in muscle shape and the presence of abnormal high signal within the injured muscle. These areas of high signal were noted on both T1-weighted and T2-weighted scans and were presumed to represent areas of intramuscular hemorrhage. (orig.)

  15. Clinical magnetic resonance: imaging and spectroscopy

    International Nuclear Information System (INIS)

    Andrew, E.R.; Bydder, Graeme; Griffiths, John; Iles, Richard; Styles, Peter

    1990-01-01

    This book begins with a readable, comprehensive but non-mathematical introduction to the basic underlying principles of magnetic resonance. Further chapters include information on the theory and principles of MRI and MRS, the interpretation of MR images, the clinical applications and scope of MRI and MRS, practical aspects of spectroscopy and magnetic resonance, and also the practical problems associated with the siting, safety and operation of large MRI and MRS equipment. (author)

  16. Magnetic movement of biological fluid droplets

    International Nuclear Information System (INIS)

    Garcia, Antonio A.; Egatz-Gomez, Ana; Lindsay, Solitaire A.; Dominguez-Garcia, P.; Melle, Sonia; Marquez, Manuel; Rubio, Miguel A.; Picraux, S.T.; Yang, Dongqing; Aella, P.; Hayes, Mark A.; Gust, Devens; Loyprasert, Suchera; Vazquez-Alvarez, Terannie; Wang, Joseph

    2007-01-01

    Magnetic fields can be used to control the movement of aqueous drops on non-patterned, silicon nanowire superhydrophobic surfaces. Drops of aqueous and biological fluids are controlled by introducing magnetizable carbonyl iron microparticles into the liquid. Key elements of operations such as movement, coalescence, and splitting of water and biological fluid drops, as well as electrochemical measurement of an analyte are demonstrated. Superhydrophobic surfaces were prepared using vapor-liquid-solid (VLS) growth systems followed by coating with a perfluorinated hydrocarbon molecule. Drops were made from aqueous and biological fluid suspensions with magnetizable microparticle concentrations ranging from 0.1 to 10 wt%

  17. Self-contained inflatable penile prosthesis: magnetic resonance appearance

    International Nuclear Information System (INIS)

    Levin, M.F.; Munk, P.L.; Vellet, A.D.; Chin, J.L.

    1994-01-01

    The appearance of an inflatable penile prosthesis, visualized on a short tau inversion recovery sequence, is reported, in a patient who had magnetic resonance imaging for pelvic pain subsequent to radical cystoprostatectomy for bladder carcinoma. With suppression of adjacent fat signal, the prosthesis is well delineated from adjacent structures. The fluid-containing cylinders of the prosthesis are of very bright signal intensity, with the relief valve assembly of low signal intensity. 5 refs., 2 figs

  18. Schistosomiasis of the spinal cord value of magnetic resonance imaging

    International Nuclear Information System (INIS)

    Masson, C.; Rey, A.; Ast, G.; Cambier, J.; Masson, M.

    1990-01-01

    The authors report a case of spinal cord schistosomiasis presenting as myelitis, with rapidly developing deficit, signs of severe cerebrospinal fluid inflammation, normal myelography and computerized tomography. The patient's country of origin suggested schistosomiasis, and the diagnosis was confirmed by serology and rectal biopsy which showed eggs of Schistosoma mansoni. Magnetic resonance imaging was helpful as it confirmed the absence of spinal cord compression and showed a lesion of the conus medullaris, this region being the most frequent site of schistosomial myelitis [fr

  19. Magnetic method for stimulating transport in fluids

    Science.gov (United States)

    Martin, James E.; Solis, Kyle J.

    2016-10-18

    A method for producing mass and heat transport in fluids, wherein the method does not rely on conventional convection, that is, it does not require gravity, a thermal gradient, or a magnetic field gradient. This method gives rise to a unique class of vigorous, field-controllable flow patterns termed advection lattices. The advection lattices can be used to transport heat and/or mass in any desired direction using only magnetic fields.

  20. Nuclear magnetic resonance method and apparatus

    International Nuclear Information System (INIS)

    Burl, M.; Young, I.R.

    1984-01-01

    A method and apparatus for determining the rate of flow of a liquid in a selected region of a body by nuclear magnetic resonance techniques are described. The method includes a sequence of applying a first magnetic pulse effective to excite nuclear magnetic resonance of a chosen nucleus within the liquid preferentially in a slice of the body which includes the selected region. A period of time (tsub(D)) is waited and then a second magnetic pulse is applied which is effective to excite nuclear magnetic resonance of the nuclei preferentially in the slice, and the free induction decay signal is measured. The whole sequence is repeated for different values of the period of time (tsub(D)). The variation in the value of the measured signal with tsub(D) is then related to the rate of flow of the liquid through the slice. (author)

  1. Resonance double magnetic bremsstrahlung in a strong magnetic field

    International Nuclear Information System (INIS)

    Fomin, P.I.; Kholodov, R.I.

    2003-01-01

    The possibility of resonance double magnetic bremsstrahlung in the approximation of weakly excited electron states in a strong external magnetic field is analyzed. The differential probability of this process in the Breit-Wigner form is obtained. The probability of double magnetic bremsstrahlung (second-order process of perturbation theory) is compared with the probability of magnetic bremsstrahlung (first-order process of perturbation theory)

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the inside of ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  4. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... help detect certain chronic diseases of the nervous system, such as multiple sclerosis diagnose problems with the ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) of the head uses a powerful magnetic field, radio waves and a computer to produce detailed ... there’s a possibility you are pregnant. The magnetic field is not harmful, but it may cause some ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. Your child will lie on a moveable examination ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table ...

  8. Spontaneous intracranial hypotension syndrome: magnetic resonance findings in two patients

    International Nuclear Information System (INIS)

    Ortega, R.; Pastor, J.; Escamilla, F.; Romero, M. I.

    1999-01-01

    The postural headache syndrome associated with a decrease in the cerebrospinal fluid (CSF) pressure is generally secondary to the CSF leakage that usually occurs after diagnostic lumbar puncture. Spontaneous intracranial hypotension can not be attributed to any known cause or previous diagnostic or therapeutic intervention. The syndrome is characterized by severe headache that is relieved by lying supine. During lumbar puncture, the CSF pressure is normally low. We present two patients in whom gadolinium-enhanced magnetic resonance imaging showed widespread thickening and enhancement of the dura mater and subdural fluid collections. (Author) 13 refs

  9. Magnetic islands created by resonant helical windings

    International Nuclear Information System (INIS)

    Fernandes, A.S.; Heller, M.V.; Caldas, I.L.

    1986-01-01

    The triggering of disruptive instabilities by resonant helical windings in large aspect-ratio tokamaks is associated to destruction of magnetic surfaces. The Chirikov condition is applied to estimate analytically the helical winding current thresholds for ergodization of the magnetic field lines. (Autor) [pt

  10. Topical questions in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Andrew, E.R.; Florida Univ., Gainesville, FL; Florida Univ., Gainesville, FL

    1989-01-01

    This paper examines a number of practical questions concerning magnetic resonance imaging. These include the choice of operating magnetic field strength, the problem of siting and screening, a procedure for securing precise slice selection and the use of paramagnetic contrast agents. (author). 5 refs

  11. Basis of the nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Bahceli, S.

    1996-08-01

    The aim of this book which is translated from English language is to explain the physical and mathematical basis of nuclear magnetic resonance (NMR). There are nine chapters covering different aspects of NMR. In the firs chapter fundamental concepts of quantum mechanics are given at a level suitable for readers to understand NMR fully. The remaining chapters discuss the magnetic properties of nucleus, the interactions between atoms and molecules, continuous wave NMR, pulsed NMR, nuclear magnetic relaxation and NMR of liquids

  12. Magnetic resonance imaging of the normal placenta

    International Nuclear Information System (INIS)

    Blaicher, Wibke; Brugger, Peter C.; Mittermayer, Christoph; Schwindt, Jens; Deutinger, Josef; Bernaschek, Gerhard; Prayer, Daniela

    2006-01-01

    The goal of this study was to provide a representative description of the normal placenta with contrast medium-free magnetic resonance imaging (MRI) in order to determine a standard of reference. One hundred consecutive singleton pregnancies were investigated by MRI without application of a contrast medium. The mean gestational age (GA) at the time of investigation was 29.5 weeks (range 19-40). Patients with suspected utero-placental insufficiency (UPI) or placental anomalies were excluded. Signal intensities were assessed and correlated with the respective GA. Antenatal MRI without contrast medium was able to depict placental status and morphological changes during gestation. A regular homogeneous structure was found in weeks 19-23. Subsequently, sporadic, slightly marked lobules appeared, which increased in number and markedness with ongoing gestation. Stratification of the lobules was observed after 36 weeks. The ratio of placental and amniotic fluid signal intensities decreased significantly with higher GA and with placental grading. MRI is well suited as an imaging method for the placenta. Our data may be used as a reference in the assessment of the placenta on MRI, and may have further clinical impact with respect to the determination of UPI

  13. Neural network segmentation of magnetic resonance images

    International Nuclear Information System (INIS)

    Frederick, B.

    1990-01-01

    Neural networks are well adapted to the task of grouping input patterns into subsets which share some similarity. Moreover, once trained, they can generalize their classification rules to classify new data sets. Sets of pixel intensities from magnetic resonance (MR) images provide a natural input to a neural network; by varying imaging parameters, MR images can reflect various independent physical parameters of tissues in their pixel intensities. A neural net can then be trained to classify physically similar tissue types based on sets of pixel intensities resulting from different imaging studies on the same subject. This paper reports that a neural network classifier for image segmentation was implanted on a Sun 4/60, and was tested on the task of classifying tissues of canine head MR images. Four images of a transaxial slice with different imaging sequences were taken as input to the network (three spin-echo images and an inversion recovery image). The training set consisted of 691 representative samples of gray matter, white matter, cerebrospinal fluid, bone, and muscle preclassified by a neuroscientist. The network was trained using a fast backpropagation algorithm to derive the decision criteria to classify any location in the image by its pixel intensities, and the image was subsequently segmented by the classifier

  14. Magnetic resonance imaging of the normal placenta

    Energy Technology Data Exchange (ETDEWEB)

    Blaicher, Wibke [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria)]. E-mail: wibke.blaicher@meduniwien.ac.at; Brugger, Peter C. [Center of Anatomy and Cell Biology, University Hospital of Vienna (Austria); Mittermayer, Christoph [Department of Pediatrics, Division of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Schwindt, Jens [Department of Pediatrics, Division of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Deutinger, Josef [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria); Bernaschek, Gerhard [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria); Prayer, Daniela [Department of Radiology, Division of Neuroradiology, University Hospital of Vienna (Austria)

    2006-02-15

    The goal of this study was to provide a representative description of the normal placenta with contrast medium-free magnetic resonance imaging (MRI) in order to determine a standard of reference. One hundred consecutive singleton pregnancies were investigated by MRI without application of a contrast medium. The mean gestational age (GA) at the time of investigation was 29.5 weeks (range 19-40). Patients with suspected utero-placental insufficiency (UPI) or placental anomalies were excluded. Signal intensities were assessed and correlated with the respective GA. Antenatal MRI without contrast medium was able to depict placental status and morphological changes during gestation. A regular homogeneous structure was found in weeks 19-23. Subsequently, sporadic, slightly marked lobules appeared, which increased in number and markedness with ongoing gestation. Stratification of the lobules was observed after 36 weeks. The ratio of placental and amniotic fluid signal intensities decreased significantly with higher GA and with placental grading. MRI is well suited as an imaging method for the placenta. Our data may be used as a reference in the assessment of the placenta on MRI, and may have further clinical impact with respect to the determination of UPI.

  15. Magnetic nanoparticles in magnetic resonance imaging and diagnostics.

    Science.gov (United States)

    Rümenapp, Christine; Gleich, Bernhard; Haase, Axel

    2012-05-01

    Magnetic nanoparticles are useful as contrast agents for magnetic resonance imaging (MRI). Paramagnetic contrast agents have been used for a long time, but more recently superparamagnetic iron oxide nanoparticles (SPIOs) have been discovered to influence MRI contrast as well. In contrast to paramagnetic contrast agents, SPIOs can be functionalized and size-tailored in order to adapt to various kinds of soft tissues. Although both types of contrast agents have a inducible magnetization, their mechanisms of influence on spin-spin and spin-lattice relaxation of protons are different. A special emphasis on the basic magnetism of nanoparticles and their structures as well as on the principle of nuclear magnetic resonance is made. Examples of different contrast-enhanced magnetic resonance images are given. The potential use of magnetic nanoparticles as diagnostic tracers is explored. Additionally, SPIOs can be used in diagnostic magnetic resonance, since the spin relaxation time of water protons differs, whether magnetic nanoparticles are bound to a target or not.

  16. Magnetic resonance imaging of the fetal brain.

    Science.gov (United States)

    Tee, L Mf; Kan, E Yl; Cheung, J Cy; Leung, W C

    2016-06-01

    This review covers the recent literature on fetal brain magnetic resonance imaging, with emphasis on techniques, advances, common indications, and safety. We conducted a search of MEDLINE for articles published after 2010. The search terms used were "(fetal OR foetal OR fetus OR foetus) AND (MR OR MRI OR [magnetic resonance]) AND (brain OR cerebral)". Consensus statements from major authorities were also included. As a result, 44 relevant articles were included and formed the basis of this review. One major challenge is fetal motion that is largely overcome by ultra-fast sequences. Currently, single-shot fast spin-echo T2-weighted imaging remains the mainstay for motion resistance and anatomical delineation. Recently, a snap-shot inversion recovery sequence has enabled robust T1-weighted images to be obtained, which is previously a challenge for standard gradient-echo acquisitions. Fetal diffusion-weighted imaging, diffusion tensor imaging, and magnetic resonance spectroscopy are also being developed. With multiplanar capabilities, superior contrast resolution and field of view, magnetic resonance imaging does not have the limitations of sonography, and can provide additional important information. Common indications include ventriculomegaly, callosum and posterior fossa abnormalities, and twin complications. There are safety concerns about magnetic resonance-induced heating and acoustic damage but current literature showed no conclusive evidence of deleterious fetal effects. The American College of Radiology guideline states that pregnant patients can be accepted to undergo magnetic resonance imaging at any stage of pregnancy if risk-benefit ratio to patients warrants that the study be performed. Magnetic resonance imaging of the fetal brain is a safe and powerful adjunct to sonography in prenatal diagnosis. It can provide additional information that aids clinical management, prognostication, and counselling.

  17. Magnetic resonance imaging: effects of magnetic field strength

    International Nuclear Information System (INIS)

    Crooks, L.E.; Arakawa, M.; Hoenninger, J.; McCarten, B.; Watts, J.; Kaufman, L.

    1984-01-01

    Magnetic resonance images of the head, abdomen, and pelvis of normal adult men were obtained using varying magnetic field strength, and measurements of T1 and T2 relaxations and of signal-to-noise (SN) ratios were determined. For any one spin echo sequence, gray/white matter contrast decreases and muscle/fat contrast increases with field. SN levels rise rapidly up to 3.0 kgauss and then change more slowly, actually dropping for muscle. The optimum field for magnetic resonance imaging depends on tissue type, body part, and imaging sequence, so that it does not have a unique value. Magnetic resonance systems that operate in the 3.0-5.0 kgauss range achieve most or all of the gains that can be achieved by higher magnetic fields

  18. Streaming flows produced by oscillating interface of magnetic fluid adsorbed on a permanent magnet in alternating magnetic field

    Science.gov (United States)

    Sudo, S.; Ito, M.; Ishimoto, Y.; Nix, S.

    2017-04-01

    This paper describes microstreaming flows generated by oscillating interface of magnetic fluid adsorbed on a circular cylindrical permanent magnet in alternating magnetic field. The interface of magnetic fluid adsorbed on the NdFeB magnet responds to the external alternating magnetic flied as harmonic oscillation. The directions of alternating magnetic field are parallel and antiparallel to the magnetic field of permanent magnet. The oscillation of magnetic fluid interface generates streaming flow around the magnet-magnetic fluid element in water. Microstreaming flows are observed with a high-speed video camera analysis system. The flow pattern generated by magnetic fluid motion depends on the Keulegan-Carpenter number and the Reynolds number.

  19. Thermomechanic equations for magnetic fluids of equilibrium magnetization

    International Nuclear Information System (INIS)

    Bashtovoy, V.G.; Berkovsky, B.M.; Vislovich, A.N.

    1988-01-01

    The main physical prerequisite for the existence of equilibrium magnetization is the assumption that nothing, except thermal motion, hinders the orientation of elementary magnetic moments along the field and that the mean value of magnetization is achieved instantaneously, i.e., within the times much shorter than the characteristic times of macroscopic processes (hydrodynamic, thermal, electromagnetic, etc.). This assumption makes it possible to consider the fluid magnetization vector M-vector at a given instant to be parallel to the vector of magnetic field intensity H-vector, which in the general form may be related as M-vector = (M/H)H-vector. Magnetization M is determined by the fluid temperature and density and by field intensity: M = M(T,rho,H). It is natural that it decreases with rising temperature and increases with the field intensity. The condition for the vectors M-vector and H-vector to be parallel is realized in a MF only for certain colloid characteristics. Nevertheless, for a wide range of problems this condition may be regarded as fulfilled and enables one to study those effects in a MF which are caused to occur by the volume magnetic force due to the interaction between equilibrium magnetization and the magnetic field

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... stroke infections developmental anomalies hydrocephalus — dilatation of fluid spaces within the brain (ventricles) causes of epilepsy (seizure) ... MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want to ask your ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... can help diagnose conditions such as: brain tumors stroke infections developmental anomalies hydrocephalus — dilatation of fluid spaces ... MRA page for more information. MRI can detect stroke at a very early stage by mapping the ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... medically necessary. MRI may not always distinguish between cancer tissue and fluid, known as edema . MRI typically ... Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association top ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... conditions such as: brain tumors stroke infections developmental anomalies hydrocephalus — dilatation of fluid spaces within the brain ( ... follow-up exam is done because a potential abnormality needs further evaluation with additional views or a ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... information on the chemicals present in the body's cells, may also be performed during the MRI exam ... medically necessary. MRI may not always distinguish between cancer tissue and fluid, known as edema . MRI typically ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... fluid spaces within the brain (ventricles) causes of epilepsy (seizure) hemorrhage in selected trauma patients certain chronic ... data suggest that it is safe to continue breastfeeding after receiving intravenous contrast. For further information please ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... fluid spaces within the brain (ventricles) causes of epilepsy (seizure) hemorrhage in selected trauma patients certain chronic conditions, such as multiple sclerosis disorders of the eye and inner ear disorders of ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI examination poses almost no risk to the average patient when appropriate safety guidelines are followed. If ... tissue and fluid, known as edema . MRI typically costs more and may take more time to perform ...

  10. Apparatus and method for handling magnetic particles in a fluid

    Science.gov (United States)

    Holman, David A.; Grate, Jay W.; Bruckner-Lea, Cynthia J.

    2000-01-01

    The present invention is an apparatus and method for handling magnetic particles suspended in a fluid, relying upon the known features of a magnetic flux conductor that is permeable thereby permitting the magnetic particles and fluid to flow therethrough; and a controllable magnetic field for the handling. The present invention is an improvement wherein the magnetic flux conductor is a monolithic porous foam.

  11. Diagnostic apparatus employing nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Hoshino, K.; Yamada, N.; Yoshitome, E.; Matsuura, H.

    1987-01-01

    An NMR diagnostic apparatus is described comprising means for applying a primary magnetic field to a subject; means for applying RF pulses to the subject to give nuclear magnetic resonance to the nuclei of atoms in the subject; means for applying gradient magnetic fields to project an NMR signal of the nuclei at least in one direction; means for observing the NMR signal projected by the gradient magnetic fields applying means; and arithmetic means for constructing a distribution of information on resonance energy as an image from an output signal from the observing means; wherein the gradient magnetic fields applying means comprises means for applying the gradient magnetic fields at a predetermined time and for not applying the gradient magnetic fields at another predetermined time, during the time period of one view; and wherein the gradient magnetic fields applying means further comprises means for measuring the NMR signal during the predetermined time when the gradient magnetic fields are applied, and means for measuring the intensity of the primary magnetic field during the other predetermined time when no gradient magnetic fields are applied

  12. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... vision or seizures help detect certain chronic diseases of the nervous system, such as multiple sclerosis diagnose problems with the ... moveable examination table that slides into the center of the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  13. Fluid mechanics aspects of magnetic drug targeting.

    Science.gov (United States)

    Odenbach, Stefan

    2015-10-01

    Experiments and numerical simulations using a flow phantom for magnetic drug targeting have been undertaken. The flow phantom is a half y-branched tube configuration where the main tube represents an artery from which a tumour-supplying artery, which is simulated by the side branch of the flow phantom, branches off. In the experiments a quantification of the amount of magnetic particles targeted towards the branch by a magnetic field applied via a permanent magnet is achieved by impedance measurement using sensor coils. Measuring the targeting efficiency, i.e. the relative amount of particles targeted to the side branch, for different field configurations one obtains targeting maps which combine the targeting efficiency with the magnetic force densities in characteristic points in the flow phantom. It could be shown that targeting efficiency depends strongly on the magnetic field configuration. A corresponding numerical model has been set up, which allows the simulation of targeting efficiency for variable field configuration. With this simulation good agreement of targeting efficiency with experimental data has been found. Thus, the basis has been laid for future calculations of optimal field configurations in clinical applications of magnetic drug targeting. Moreover, the numerical model allows the variation of additional parameters of the drug targeting process and thus an estimation of the influence, e.g. of the fluid properties on the targeting efficiency. Corresponding calculations have shown that the non-Newtonian behaviour of the fluid will significantly influence the targeting process, an aspect which has to be taken into account, especially recalling the fact that the viscosity of magnetic suspensions depends strongly on the magnetic field strength and the mechanical load.

  14. Embroidered Coils for Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Michael I. Newton

    2013-04-01

    Full Text Available Magnetic resonance imaging is a widely used technique for medical and materials imaging. Even though the objects being imaged are often irregularly shaped, suitable coils permitting the measurement of the radio-frequency signal in these systems are usually made of solid copper. One problem often encountered is how to ensure the coils are both in close proximity and conformal to the object being imaged. Whilst embroidered conductive threads have previously been used as antennae in mobile telecommunications applications, they have not previously been reported for use within magnetic resonance. In this paper we show that an embroidered single loop coil can be used in a commercial unilateral nuclear magnetic resonance system as an alternative to a solid copper. Data is presented showing the determination of both longitudinal (T1 and effective transverse (T2eff relaxation times for a flat fabric coil and the same coil conformed to an 8 cm diameter cylinder. We thereby demonstrate the principles required for the wider use of fabric based conformal coils within nuclear magnetic resonance and magnetic resonance imaging.

  15. Application of MRIL-WD (Magnetic Resonance Imaging Logging While Drilling) for irreducible water saturation, total reservoir, free-fluid, bound-fluid porosity measurements and its value for the petrophysical analysis of RT/RM data from the Shah Deniz well

    Science.gov (United States)

    Amirov, Elnur

    2016-04-01

    Sperry-Sun (Sperry Drilling Services) is the leader in MWD/LWD reliability, has developed the industry's first LWD NMR/MRIL-WD (nuclear magnetic resonance) tool. The MRIL-WD (magnetic resonance imaging logging-while-drilling) service directly measures the T1 component of hydrogen in subsurface rock units while drilling to obtain total reservoir porosity and to dissect the observed total porosity into its respective components of free fluid and bound fluid porosity. These T1 data are used to secure accurate total, free-fluid, capillary-bound water, and clay-bound water porosity of the reservoir sections which can be drilled in the several Runs. Over the last decade, results from Magnetic Resonance Imaging logs (NMR) have added significant value to petrophysical analysis and understanding by providing total, free-fluid and bound-fluid porosities, combined with fluid typing capabilities. With MRIL-WD very valuable Real-Time or Recorded Memory data/information is now available during or shortly after the drilling operation (formation properties measurement can be taken right after a drill bit penetration), while trip in and trip out as well. A key point in utilizing MRIL in an LWD environment is motion-tolerant measurements. Recent MRIL-WD logging runs from the Shah Deniz wells located in the Khazarian-Caspian Sea of the Azerbaijan Republic helped to delineate and assess hydrocarbon bearing zones. Acquired results demonstrate how MRIL data can be acquired while-drilling and provide reliable/high quality measurements. Magnetic Resonance Imaging logs at some developments wells have become a cornerstone in formation evaluation and petrophysical understanding. By providing total, free-fluid, and bound-fluid porosities together with fluid typing, MRIL results have significantly added to the assessment of reservoirs. In order to reduce NPT (Non-Productive Time) and save the rig operations time, there is always the desire to obtain logging results as soon as possible

  16. Magnetic resonance signal moment determination using the Earth's magnetic field

    KAUST Repository

    Fridjonsson, Einar Orn; Creber, Sarah A.; Vrouwenvelder, Johannes S.; Johns, Michael L.

    2015-01-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth's magnetic field system.

  17. Magnetic resonance signal moment determination using the Earth's magnetic field

    KAUST Repository

    Fridjonsson, Einar Orn

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth\\'s magnetic field system.

  18. Generation of nuclear magnetic resonance images

    International Nuclear Information System (INIS)

    Beckmann, N.X.

    1986-01-01

    Two generation techniques of nuclear magnetic resonance images, the retro-projection and the direct transformation method are studied these techniques are based on the acquisition of NMR signals which phases and frequency components are codified in space by application of magnetic field gradients. The construction of magnet coils is discussed, in particular a suitable magnet geometry with polar pieces and air gap. The obtention of image contrast by T1 and T2 relaxation times reconstructed from generated signals using sequences such as spin-echo, inversion-recovery and stimulated echo, is discussed. The mathematical formalism of matrix solution for Bloch equations is also presented. (M.C.K.)

  19. Susceptibility effects in nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ziener, Christian Herbert

    2008-01-01

    The properties of dephasing and the resulting relaxation of the magnetization are the basic principle on which all magnetic resonance imaging methods are based. The signal obtained from the gyrating spins is essentially determined by the properties of the considered tissue. Especially the susceptibility differences caused by magnetized materials (for example, deoxygenated blood, BOLD-effect) or magnetic nanoparticles are becoming more important for biomedical imaging. In the present work, the influence of such field inhomogeneities on the NMR-signal is analyzed. (orig.)

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a risk, depending on their nature and the strength of the MRI magnet. Many implanted devices will ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... and extremities. Tell your doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic ... the radiologist if your child has any serious health problems or has recently had surgery. Some conditions, ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, ... to the heart muscle evaluate findings following cardiovascular surgery In the abdominal and pelvic region, MRI is ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... material called gadolinium, which is less likely to cause an allergic reaction than iodinated contrast material. Tell ... magnetic field is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... distort images of the facial area or brain, so you should let the radiologist know about them. ... MRI units, called short-bore systems , are designed so that the magnet does not completely surround you. ...

  6. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... distort images of the facial area or brain, so the radiologist should be aware of them. Parents ... MRI units, called short-bore systems , are designed so that the magnet does not completely surround you. ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if you have asthma. The contrast material ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if your child has asthma. The contrast ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... interfere with the magnetic field of the MRI unit, metal and electronic items are not allowed in ... the MRI equipment look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... interfere with the magnetic field of the MRI unit, metal and electronic items are not allowed in ... does the equipment look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... an MRI scan, but this is rare. Tooth fillings and braces usually are not affected by the magnetic field, but they may distort images of the facial area or brain, so you should let the ...

  12. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... lodged in the eyes are particularly important. Tooth fillings and braces usually are not affected by the magnetic field, but they may distort images of the facial area or brain, so the radiologist should be ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... traditional MRI unit is a large cylinder-shaped tube surrounded by a circular magnet. You will lie ... your skin at the site of the IV tube insertion. Some patients may sense a temporary metallic ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... traditional MRI unit is a large cylinder-shaped tube surrounded by a circular magnet. Your child will ... skin irritation at the site of the IV tube insertion. Some patients may sense a temporary metallic ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... regular daily routine and have him/her take food and medications as usual. Some MRI examinations may ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... if your child has any implanted medical or electronic devices. Inform your doctor and the technologist prior ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. ... signals that are detected by the coils. The electric current does not come in contact with the ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. ... signals that are detected by the coils. The electric current does not come in contact with the ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Magnetic ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... pregnant. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... number of abrupt onset or long-standing symptoms. It can help diagnose conditions such as: brain tumors ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... allergies. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... cord is needed, MRI is useful because of its ability to see through the skull and the ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... about pregnancy and MRI. If you have claustrophobia (fear of enclosed spaces) or anxiety, you may want ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography ( ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... allergies and whether there’s a possibility you are pregnant. The magnetic field is not harmful, but it ... if there is any possibility that they are pregnant. MRI has been used for scanning patients since ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) procedure View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic ...

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... two-way intercom. Many MRI centers allow a parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it ... the exam if your child has a known allergy to contrast material. Your child should wear loose, ...

  12. Magnetic resonance imaging of breast implants.

    Science.gov (United States)

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  13. Magnetic resonance enterography in pediatric celiac disease.

    Science.gov (United States)

    Koc, Gonca; Doganay, Selim; Sevinc, Eylem; Deniz, Kemal; Chavhan, Govind; Gorkem, Sureyya B; Karacabey, Neslihan; Dogan, Mehmet S; Coskun, Abdulhakim; Aslan, Duran

    To assess if magnetic resonance enterography is capable of showing evidence/extent of disease in pediatric patients with biopsy-proven celiac disease by comparing with a control group, and to correlate the magnetic resonance enterography findings with anti-endomysial antibody level, which is an indicator of gluten-free dietary compliance. Thirty-one pediatric patients (mean age 11.7±3.1 years) with biopsy-proven celiac disease and 40 pediatric patients as a control group were recruited in the study. The magnetic resonance enterography images of both patients with celiac disease and those of the control group were evaluated by two pediatric radiologists in a blinded manner for the mucosal pattern, presence of wall thickening, luminal distention of the small bowel, and extra-intestinal findings. Patient charts were reviewed to note clinical features and laboratory findings. The histopathologic review of the duodenal biopsies was re-conducted. The mean duration of the disease was 5.6±1.8 years (range: 3-7.2 years). In 24 (77%) of the patients, anti-endomysial antibody levels were elevated (mean 119.2±66.6RU/mL). Magnetic resonance enterography revealed normal fold pattern in all the patients. Ten (32%) patients had enlarged mesenteric lymph nodes. Although a majority of the patients had elevated anti-endomysial antibody levels indicating poor dietary compliance, magnetic resonance enterography did not show any mucosal abnormality associated with the inability of magnetic resonance enterography to detect mild/early changes of celiac disease in children. Therefore, it may not be useful for the follow-up of pediatric celiac disease. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  14. Magnetic resonance imaging of popliteal artery pathologies

    International Nuclear Information System (INIS)

    Holden, Andrew; Merrilees, Stephen; Mitchell, Nicola; Hill, Andrew

    2008-01-01

    This paper illustrates examples of popliteal artery pathologies imaged with contrast enhanced magnetic resonance angiography (CE-MRA) and magnetic resonance imaging (MRI) at a single tertiary referral centre. Popliteal artery pathologies were identified in 1710 patients referred over a 6-year period with symptoms suggesting lower limb arterial occlusive disease. Common pathologies such as atherosclerotic occlusive disease, thromboemboli and aneurysm disease are discussed as well as unusual pathologies such as cystic adventitial disease, mycotic aneurysm and arterial entrapment. The combination of CE-MRA and the excellent soft tissue resolution of MRI allow detailed evaluation of arterial and peri-arterial pathologies, and facilitate appropriate management decisions

  15. Magnetic resonance imaging of popliteal artery pathologies

    Energy Technology Data Exchange (ETDEWEB)

    Holden, Andrew [Department of Radiology, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: andrewh@adhb.govt.nz; Merrilees, Stephen [Department of Radiology, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: smerrilees@adhb.govt.nz; Mitchell, Nicola [Department of Radiology, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: nmit010@ec.auckland.ac.nz; Hill, Andrew [Department of Vascular Surgery, Auckland City Hospital, Park Road, Grafton, Auckland 9 (New Zealand)], E-mail: ahill@adhb.govt.nz

    2008-07-15

    This paper illustrates examples of popliteal artery pathologies imaged with contrast enhanced magnetic resonance angiography (CE-MRA) and magnetic resonance imaging (MRI) at a single tertiary referral centre. Popliteal artery pathologies were identified in 1710 patients referred over a 6-year period with symptoms suggesting lower limb arterial occlusive disease. Common pathologies such as atherosclerotic occlusive disease, thromboemboli and aneurysm disease are discussed as well as unusual pathologies such as cystic adventitial disease, mycotic aneurysm and arterial entrapment. The combination of CE-MRA and the excellent soft tissue resolution of MRI allow detailed evaluation of arterial and peri-arterial pathologies, and facilitate appropriate management decisions.

  16. Magnetic elliptical polarization of Schumann resonances

    International Nuclear Information System (INIS)

    Sentman, D.D.

    1987-01-01

    Measurements of orthogonal, horizontal components of the magnetic field in the ELF range obtained during September 1985 show that the Schumann resonance eigenfrequencies determined separately for the north-south and east-west magnetic components differ by as much as 0.5 Hz, suggesting that the underlying magnetic signal is not linearly polarized at such times. The high degree of magnetic ellipticity found suggests that the side multiplets of the Schumann resonances corresponding to azimuthally inhomogeneous normal modes are strongly excited in the highly asymmetric earth-ionosphere cavity. The dominant sense of polarization over the measurement passband is found to be right-handed during local daylight hours, and to be left-handed during local nighttime hours. 16 references

  17. Proton magnetic resonance spectroscopy and perfusion magnetic resonance imaging in the evaluation of musculoskeletal tumors

    International Nuclear Information System (INIS)

    Costa, Flavia Martins; Setti, Marcela; Vianna, Evandro Miguelote; Domingues, Romulo Cortes; Meohas, Walter; Rezende, Jose Francisco; Gasparetto, Emerson Leandro

    2009-01-01

    Objective: To assess the role of proton magnetic resonance spectroscopy and dynamic contrast-enhanced magnetic resonance imaging in the differentiation between malignant and benign musculoskeletal tumors. Materials And Methods: Fifty-five patients with musculoskeletal tumors (27 malignant and 28 benign) were studied. The examinations were performed in a 1.5 T magnetic resonance scanner with standard protocol, and single voxel proton magnetic resonance spectroscopy with 135 msec echo time. The dynamic contrast study was performed using T1-weighted gradient-echo sequence after intravenous gadolinium injection. Time signal intensity curves and slope values were calculated. The statistical analysis was performed with the Levene's test, followed by a Student's t-test, besides the Pearson's chi-squared and Fischer's exact tests. Results: Proton magnetic resonance spectroscopy sensitivity, specificity and accuracy were, respectively, 87.5%, 92.3% and 90.9% (p < 0.0001). Statistically significant difference was observed in the slope (%/min) between benign (mean, 27.5%/min) and malignant (mean, 110.9%/min) lesions (p < 0.0001). Conclusion: The time-intensity curve and slope values using dynamic-enhanced perfusion magnetic resonance imaging in association with the presence of choline peak demonstrated by single voxel magnetic resonance spectroscopy study are useful in the differentiation between malignant and benign musculoskeletal tumors. (author)

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... ill effects on pregnant women or their unborn babies. However, because the unborn baby will be in a strong magnetic field, pregnant ... intravenous contrast indicate mothers should not breastfeed their babies for 24-48 hours after contrast medium is ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... epilepsy (seizure) hemorrhage in selected trauma patients certain chronic conditions, such as multiple sclerosis disorders of the ... a very small chance of irritation of your skin at the site of the IV tube insertion. Some ... Images related to Magnetic ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic ... patient to have an allergy to a gadolinium-based contrast agent used for MRI than the iodine- ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... which they come. The MR scanner captures this energy and creates a picture of the tissues scanned based on this information. The magnetic field is produced by passing an electric current through wire coils in most MRI units. ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... which they come. The MR scanner captures this energy and creates a picture of the tissues scanned based on this information. The magnetic field is produced by passing an electric current through wire coils in most MRI units. ...

  4. Nuclear magnetic resonance (NMR) tomography

    International Nuclear Information System (INIS)

    Skalpe, I.O.

    1984-01-01

    A brief survey of the working principle of the NMR technique in diagnostical medicine is given. Its clinical usefulness for locating tumors, diagnosing various other diseases, such as some mental illnesses and multiple sclerosis, and its possibilities for studying biochemical processes in vivo are mentioned. The price of NMR image scanners and the problems of the strong magnetic field around the machines are mentioned

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... MRI equipment look like? How does the procedure work? How is the ... use to diagnose medical conditions. MRI uses a powerful magnetic field, radio frequency ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... the equipment look like? How does the procedure work? How is the ... use to diagnose medical conditions. MRI uses a powerful magnetic field, radio frequency ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... to see, hear and speak with your child at all times using a two-way intercom. Many MRI centers allow a parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... able to see, hear and speak with you at all times using a two-way intercom. Many MRI centers allow a friend or parent to stay in the room as long as they are also screened for safety in the magnetic environment. Children will be given ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and other cranial structures that are clearer and more detailed than other imaging methods. This exam does not use ionizing radiation and may require an injection of a ...

  10. Magnetic Resonance Features of Cerebral Malaria

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, P.; Sharma, R.; Kumar, S.; Kumar, U. (Dept. of Radiodiagnosis and Dept. of Medicine, All India Institute of Medical Sciences, New Delhi (India))

    2008-06-15

    Background: Cerebral malaria is a major health hazard, with a high incidence of mortality. The disease is endemic in many developing countries, but with a greater increase in tourism, occasional cases may be detected in countries where the disease in not prevalent. Early diagnosis and evaluation of cerebral involvement in malaria utilizing modern imaging modalities have an impact on the treatment and clinical outcome. Purpose: To evaluate the magnetic resonance (MR) features of patients with cerebral malaria presenting with altered sensorium. Material and Methods: We present the findings in three patients with cerebral malaria presenting with altered sensorium. MR imaging using a 1.5-Tesla unit was carried out. The sequences performed were 5-mm-thick T1-weighted, T2-weighted, fluid-attenuated inversion-recovery (FLAIR), and T2-weighted gradient-echo axial sequences, and sagittal and coronal FLAIR. Diffusion-weighted imaging was performed with b values of 0 and 1000 s/mm2, and apparent diffusion coefficient (ADC) maps were obtained. Results: Focal hyperintensities in the bilateral periventricular white matter, corpus callosum, occipital subcortex, and bilateral thalami were noticed on T2-weighted and FLAIR sequences. The lesions were more marked in the splenium of the corpus callosum. No enhancement on postcontrast T1-weighted MR images was observed. There was no evidence of restricted diffusion on the diffusion-weighted sequence and ADC map. Conclusion: MR is a sensitive imaging modality, with a role in the assessment of cerebral lesions in malaria. Focal white matter and corpus callosal lesions without any restricted diffusion were the key findings in our patients

  11. Magnetic Resonance Features of Cerebral Malaria

    International Nuclear Information System (INIS)

    Yadav, P.; Sharma, R.; Kumar, S.; Kumar, U.

    2008-01-01

    Background: Cerebral malaria is a major health hazard, with a high incidence of mortality. The disease is endemic in many developing countries, but with a greater increase in tourism, occasional cases may be detected in countries where the disease in not prevalent. Early diagnosis and evaluation of cerebral involvement in malaria utilizing modern imaging modalities have an impact on the treatment and clinical outcome. Purpose: To evaluate the magnetic resonance (MR) features of patients with cerebral malaria presenting with altered sensorium. Material and Methods: We present the findings in three patients with cerebral malaria presenting with altered sensorium. MR imaging using a 1.5-Tesla unit was carried out. The sequences performed were 5-mm-thick T1-weighted, T2-weighted, fluid-attenuated inversion-recovery (FLAIR), and T2-weighted gradient-echo axial sequences, and sagittal and coronal FLAIR. Diffusion-weighted imaging was performed with b values of 0 and 1000 s/mm 2 , and apparent diffusion coefficient (ADC) maps were obtained. Results: Focal hyperintensities in the bilateral periventricular white matter, corpus callosum, occipital subcortex, and bilateral thalami were noticed on T2-weighted and FLAIR sequences. The lesions were more marked in the splenium of the corpus callosum. No enhancement on postcontrast T1-weighted MR images was observed. There was no evidence of restricted diffusion on the diffusion-weighted sequence and ADC map. Conclusion: MR is a sensitive imaging modality, with a role in the assessment of cerebral lesions in malaria. Focal white matter and corpus callosal lesions without any restricted diffusion were the key findings in our patients

  12. Role of three-dimensional fluid-attenuated inversion recovery (3D FLAIR) and proton density magnetic resonance imaging for the detection and evaluation of lesion extent of focal cortical dysplasia in patients with refractory epilepsy

    International Nuclear Information System (INIS)

    Saini, Jitender; Kesavadas, Chandrasekharan; Thomas, Bejoy; Singh, Atampreet; Rathore, Chathurbhuj; Radhakrishnan, Ashalatha; Radhakrishnan, Kurupath; Bahuleyan, Biji

    2010-01-01

    Background: Focal cortical dysplasia (FCD) is often associated with epilepsy. Identification of FCD can be difficult due to subtle magnetic resonance imaging (MRI) changes. Though fluid-attenuated inversion recovery (FLAIR) sequence detects the majority of these lesions, smaller lesions may go unnoticed while larger lesions may be poorly delineated. Purpose: To determine the ability of a specialized epilepsy protocol in visualizing and delineating the extent of FCD. Material and Methods: We compared the imaging findings in nine patients with cortical malformation who underwent routine epilepsy MR imaging as well as a specialized epilepsy protocol. All imaging was done on a 1.5T MR unit. The specialized epilepsy protocol included 3D FLAIR in the sagittal plane as well as proton density (PD) and high-resolution T2-weighted (T2W) images in the transverse plane. Results: In all nine patients, the specialized protocol identified lesion anatomy better. In three patients in whom routine MRI was normal, the specialized epilepsy protocol including 3D FLAIR helped in identifying the lesions. One of these patients underwent surgery, and histo-pathology revealed a cortical dysplasia. In one patient, lesion characterization was improved, while in the remaining patients the extent of the FCD was more clearly demonstrated in the 3D FLAIR and PD images. Statistical analysis of images for cortical thickness, cortical signal intensity, adjacent white matter abnormalities, and gray-white matter junction showed significant statistical difference in the ability of 3D FLAIR to assess these aspects over conventional images. PD images were also found superior to the routine epilepsy protocol in assessment of cortical signal, adjacent white matter, and gray-white matter junction. Conclusion: Specialized MRI sequences and techniques should be performed whenever there is a high suspicion of cortical dysplasia, especially when they remain occult on conventional MR protocols. These techniques

  13. Magnetic resonance investigation of magnetic-labeled baker's yeast cells

    International Nuclear Information System (INIS)

    Godoy Morais, J.P.M.; Azevedo, R.B.; Silva, L.P.; Lacava, Z.G.M.; Bao, S.N.; Silva, O.; Pelegrini, F.; Gansau, C.; Buske, N.; Safarik, I.; Safarikova, M.; Morais, P.C.

    2004-01-01

    In this study, the interaction of DMSA-coated magnetite nanoparticles (5 and 10 nm core-size) with Saccharomyces cerevisae was investigated using magnetic resonance (MR) and transmission electron microscopy (TEM). The TEM micrographs revealed magnetite nanoparticles attached externally to the cell wall. The MR data support the strong interaction among the nanoparticles supported by the cells. A remarkable shift in the resonance field was used as signature of particle attachment to the cell wall

  14. Optimization of T2-weighted imaging for shoulder magnetic resonance arthrography by synthetic magnetic resonance imaging.

    Science.gov (United States)

    Lee, Seung Hyun; Lee, Young Han; Hahn, Seok; Yang, Jaemoon; Song, Ho-Taek; Suh, Jin-Suck

    2017-01-01

    Background Synthetic magnetic resonance imaging (MRI) allows reformatting of various synthetic images by adjustment of scanning parameters such as repetition time (TR) and echo time (TE). Optimized MR images can be reformatted from T1, T2, and proton density (PD) values to achieve maximum tissue contrast between joint fluid and adjacent soft tissue. Purpose To demonstrate the method for optimization of TR and TE by synthetic MRI and to validate the optimized images by comparison with conventional shoulder MR arthrography (MRA) images. Material and Methods Thirty-seven shoulder MRA images acquired by synthetic MRI were retrospectively evaluated for PD, T1, and T2 values at the joint fluid and glenoid labrum. Differences in signal intensity between the fluid and labrum were observed between TR of 500-6000 ms and TE of 80-300 ms in T2-weighted (T2W) images. Conventional T2W and synthetic images were analyzed for diagnostic agreement of supraspinatus tendon abnormalities (kappa statistics) and image quality scores (one-way analysis of variance with post-hoc analysis). Results Optimized mean values of TR and TE were 2724.7 ± 1634.7 and 80.1 ± 0.4, respectively. Diagnostic agreement for supraspinatus tendon abnormalities between conventional and synthetic MR images was excellent (κ = 0.882). The mean image quality score of the joint space in optimized synthetic images was significantly higher compared with those in conventional and synthetic images (2.861 ± 0.351 vs. 2.556 ± 0.607 vs. 2.750 ± 0.439; P optimized TR and TE for shoulder MRA enables optimization of soft-tissue contrast.

  15. resonant inverter supplied interior permanent magnet (ipm)

    African Journals Online (AJOL)

    user

    [5] Zhenyue Hong, “DC-voltage link resonant inverters”, Department of Electrical and. Electronic Engineering University of. Canterbury, New Zealand. [6] Kalyan Kumar Halder, Naruttam Kumar Roy and B.C. Ghosh, “Position Sensorless. Control for an Interior Permanent Magnet. Synchronous Motor SVM Drive with ANN.

  16. Magnetic resonance imaging in radiotherapy treatment planning

    NARCIS (Netherlands)

    Moerland, Marinus Adriaan

    1996-01-01

    From its inception in the early 1970's up to the present, magnetic resonance imaging (MRI) has evolved into a sophisticated technique, which has aroused considerable interest in var- ious subelds of medicine including radiotherapy. MRI is capable of imaging in any plane and does not use ionizing

  17. Pharyngeal branchial cyst: magnetic resonance findings

    Energy Technology Data Exchange (ETDEWEB)

    Cerezal, L.; Canga, A. [Department of Radiology of the ' Santa Cruz' Hospital Liencres, Cantabria (Spain); Morales, C. [Department of Otorhinolaryngology of the ' Sierrallana' Hospital Torrelavega, Cantabria (Spain); Abascal, F.; Usamentiaga, E.; Bustamante, M. [Department of Radiology of the University Hospital ' Marques de Valdecilla' , Av. de Valdecilla s/n Santander 39008 (Spain); Olcinas, O. [Department of Pathology of the University Hospital ' Marques de Valdecilla' , Av. de Valdecilla s/n Santander 39008 (Spain)

    1998-11-01

    An unusual case of pharyngeal cyst in a 25-year-old man studied by Magnetic Resonance (MR) is described. Anatomic location and pathological findings indicated the second branchial pouch origin. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  18. Pharyngeal branchial cyst: magnetic resonance findings

    International Nuclear Information System (INIS)

    Cerezal, L.; Canga, A.; Morales, C.; Abascal, F.; Usamentiaga, E.; Bustamante, M.; Olcinas, O.

    1998-01-01

    An unusual case of pharyngeal cyst in a 25-year-old man studied by Magnetic Resonance (MR) is described. Anatomic location and pathological findings indicated the second branchial pouch origin. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  19. Numerical methods in electron magnetic resonance

    International Nuclear Information System (INIS)

    Soernes, A.R.

    1998-01-01

    The focal point of the thesis is the development and use of numerical methods in the analysis, simulation and interpretation of Electron Magnetic Resonance experiments on free radicals in solids to uncover the structure, the dynamics and the environment of the system

  20. Numerical methods in electron magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Soernes, A.R

    1998-07-01

    The focal point of the thesis is the development and use of numerical methods in the analysis, simulation and interpretation of Electron Magnetic Resonance experiments on free radicals in solids to uncover the structure, the dynamics and the environment of the system.

  1. Cryogenic Preamplifiers for Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Johansen, Daniel H.; Sanchez-Heredia, Juan D.; Petersen, Jan R.

    2018-01-01

    Pursuing the ultimate limit of detection in magnetic resonance imaging (MRI) requires cryogenics to decrease the thermal noise of the electronic circuits. As cryogenic coils for MRI are slowly emerging cryogenic preamplifiers are required to fully exploit their potential. A cryogenic preamplifier...

  2. Automated Segmentation of Cardiac Magnetic Resonance Images

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Nilsson, Jens Chr.; Grønning, Bjørn A.

    2001-01-01

    Magnetic resonance imaging (MRI) has been shown to be an accurate and precise technique to assess cardiac volumes and function in a non-invasive manner and is generally considered to be the current gold-standard for cardiac imaging [1]. Measurement of ventricular volumes, muscle mass and function...

  3. Magnetic resonance imaging of xanthomatous meningioma

    International Nuclear Information System (INIS)

    Katayama, Y.; Tsubokawa, T.; Tanaka, A.; Koshinaga, M.; Nemoto, N.

    1993-01-01

    A case of meningioma with extensive xanthomatous metaplasia occurring in the left frontal convexity of a 37-year-old woman is reported. The tumour was demonstrated as a hypodense mass with minimal enhancement on CT. Our findings suggest that magnetic resonance imaging may provide a clue to the diagnosis of meningiomas with extensive xanthomatous metaplasia when CT is less specific. (orig.)

  4. Evaluation of nuclear magnetic resonance spectroscopy variability

    Energy Technology Data Exchange (ETDEWEB)

    Barreto, Felipe Rodrigues; Salmon, Carlos Ernesto Garrido, E-mail: garrido@ffclrp.usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Filisofia, Ciencias e Letras; Otaduy, Maria Concepcion Garcia [Universidade de Sao Paulo (FAMUS/USP), Sao Paulo, SP (Brazil). Fac. de Medicina. Departamento de Radiologia

    2014-11-01

    Introduction: the intrinsically high sensitivity of Magnetic Resonance Spectroscopy (MRS) causes considerable variability in metabolite quantification. In this study, we evaluated the variability of MRS in two research centers using the same model of magnetic resonance image scanner. Methods: two metabolic phantoms were created to simulate magnetic resonance spectra from in vivo hippocampus. The phantoms were filled with the same basic solution containing the following metabolites: N-acetyl-aspartate, creatine, choline, glutamate, glutamine and inositol. Spectra were acquired over 15 months on 26 acquisition dates, resulting in a total of 130 spectra per center. Results: the phantoms did not undergo any physical changes during the 15-month period. Temporal analysis from both centers showed mean metabolic variations of 3.7% in acquisitions on the same day and of 8.7% over the 15-month period. Conclusion: The low deviations demonstrated here, combined with the high specificity of Magnetic Resonance Spectroscopy, confirm that it is feasible to use this technique in multicenter studies in neuroscience research. (author)

  5. Vascular anatomy in angiography for magnetic resonance

    International Nuclear Information System (INIS)

    Charry Lopez, Marco Luciano; Rivera Gomez, Juan Enrique

    1998-01-01

    A review of basic anatomical concepts and main variants, as well as some anatomical anomalies of the central nervous system vascularity, these concepts are considered essential for the interpretation of magnetic resonance angiography with time-of-flight (TOF) and phase-contrast (PC) methods

  6. Magnetic resonance imaging in obstetric diagnosis.

    Science.gov (United States)

    Weinreb, J C; Lowe, T W; Santos-Ramos, R; Cunningham, F G; Parkey, R

    1985-01-01

    Five patients with abnormal pregnancies were examined with ultrasound (US) and magnetic resonance imaging (MR). Three had a malformed fetus, 1 had a molar pregnancy, and 1 had an ovarian mass. Both maternal and fetal structures were clearly shown, although fetal motion may have resulted in image degradation in some cases. The authors suggest that MR may be useful in obstetric diagnosis.

  7. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive ... possibility that you’re pregnant tell your doctor as well. On the day of your exam, it’s ...

  8. Magnetic resonance imaging in sudden deafness

    International Nuclear Information System (INIS)

    Ramos, Hugo Valter Lisboa; Barros, Flavia Alencar; Penido, Norma de Oliveira; Souza, Ana Claudia Valerio de; Yamaoka, Wellington Yugo; Yamashita, Helio

    2005-01-01

    The etiology of sudden deafness can remain undetermined despite extensive investigation. This study addresses the value of magnetic resonance imaging in the analysis of sudden deafness patients.Study Design: transversal cohort.Material And Method: In a prospective study, 49 patients attended at otolaryngology emergency room of Federal University of Sao Paulo - Escola Paulista de Medicina, from April 2001 to May 2003, were submitted to magnetic resonance imaging.Results: Magnetic Resonance abnormalities were seen in 23 (46.9%) patients and revealed two tumors suggestive of meningioma, three vestibular schwannomas, thirteen microangiopathic changes of the brain and five (21.7%) pathological conditions of the labyrinth.Conclusion: Sudden deafness should be approached as a symptom common to different diseases. The presence of cerebellopontine angle tumors in 10.2% of our cases, among other treatable causes, justifies the recommendation of gadolinium-enhanced magnetic resonance use, not only to study the auditory peripheral pathway, but to study the whole auditory pathway including the brain. (author)

  9. Magnetic resonance studies of solid polymers

    International Nuclear Information System (INIS)

    Lenk, R.

    1969-01-01

    This paper is a review of the application of nuclear magnetic resonance (NMR) to solid polymers. In the first, theoretical part, the elements of the theory of NMR, which are necessary for the study of the properties of solid polymers are discussed: the moments method, nuclear relaxation and the distribution of correlation times. In the second part the experimental results are presented. (author) [fr

  10. Appropriateness of computed tomography and magnetic resonance ...

    African Journals Online (AJOL)

    Introduction. Computed tomography (CT) and magnetic resonance imaging (MRI) are an essential part of modern healthcare. Marked increases in clinical demand for these imaging modalities are straining healthcare expenditure and threatening health system sustainability. The number of CT and MRI scans requested in ...

  11. Magnetic resonance imaging of the knee

    International Nuclear Information System (INIS)

    Nederveen, D.; Bakker, C.J.G.; Scholten, F.G.; Feldberg, N.A.M.; Postma, J.H.; Vis, H. van der

    1989-01-01

    Sixteen patients suspected of having meniscal lesions, were examined bt magnetic resonance (MR) and arthroscopy, MR and arthroscopy corelate well for meniscal and cruciate ligament lesions. Damage of the articular cartilage was, however, not detected by MR (author). 15 refs.; 4 figs.; 1 tab

  12. Intralabyrinthine schwannoma shown by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Saeed, S.R.; Birzgalis, A.R.; Ramsden, R.T.

    1994-01-01

    Intralabyrinthine schwannomas are rare benign tumours which present with progressive or fluctuant audiovestibular symptoms and may mimic Menieres disease. The size and position of these lesions make preoperative diagnosis unusual and most are discovered incidentally at labyrinthectomy. A case is reported which was diagnosed on magnetic resonance imaging and confirmed at surgery. (orig.)

  13. Magnetic resonance imaging of semicircular canals.

    Science.gov (United States)

    Sbarbati, A; Leclercq, F; Zancanaro, C; Antonakis, K

    1992-01-01

    The present paper reports the results of the first investigation of the semicircular canals in a living, small animal by means of high spatial resolution magnetic resonance imaging. This procedure is noninvasive and allows identification of the endolymphatic and perilymphatic spaces yielding a morphology quite consistent with direct anatomical examination. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:1506290

  14. Quantitative dosing by nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Solomon, I.

    1958-01-01

    The measurement of the absolute concentration of a heavy water reference containing approximately 99.8 per cent of D 2 O has been performed, by an original magnetic resonance method ('Adiabatic fast passage method') with a precision of 5.10 -5 on the D 2 O concentration. (author) [fr

  15. Nonlinear nuclear magnetic resonance in ferromagnets

    International Nuclear Information System (INIS)

    Nurgaliev, T.

    1988-01-01

    The properties of nonlinear nuclear magnetic resonance (NMR) have been studied theoretically by taking into account the interaction between NMR and FMR in the ferromagnets. The Landau-Lifshitz-Bloch equations, describing the electron and nuclear magnetization behaviour in ferromagnets are presented in an integral form for a weakly excited electronic system. The stationary solution of these equations has been analysed in the case of equal NMR and FMR frequencies: the criteria for the appearance of two stable dynamic states is found and the high-frequency magnetic susceptibility for these systems is investigated. 2 figs., 8 refs

  16. Interaction of magnetic resonators studied by the magnetic field enhancement

    Directory of Open Access Journals (Sweden)

    Yumin Hou

    2013-12-01

    Full Text Available It is the first time that the magnetic field enhancement (MFE is used to study the interaction of magnetic resonators (MRs, which is more sensitive than previous parameters–shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  17. Theoretical investigation of the extinction coefficient of magnetic fluid

    Energy Technology Data Exchange (ETDEWEB)

    Fang Xiaopeng; Xuan Yimin, E-mail: ymxuan@mail.njust.edu.cn; Li Qiang [Nanjing University of Science and Technology, School of Energy and Power Engineering (China)

    2013-05-15

    A new theoretical approach for calculating the extinction coefficient of magnetic fluid is proposed, which is based on molecular dynamics (MD) simulation and T-matrix method. By means of this approach, the influence of particle diameter, particle volume fraction, and external magnetic filed on the extinction coefficient of magnetic fluid is investigated. The results show that the extinction coefficient of the magnetic fluid linearly increases with increase in the particle volume fraction. For a given particle volume fraction, the extinction coefficient increases with increase in the particle diameter which varies from 5 to 20 nm. When a uniform external magnetic filed is applied to the magnetic fluid, the extinction coefficient of the magnetic fluid presents an anisotropic feature. These results agree well with the reported experimental results. The proposed approach is applicable to investigating the optical properties of magnetic fluids.

  18. Magnetic resonance imaging of infectious myositis

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Ji Young; Kim, Jee Young; Kim, Sang Heum; Jung, Youn Ju; Cha, Eun Suk; Park, Joung Mi; Park, Young Ha [The Catholic Univ., College of Medicine, Suwon (Korea, Republic of)

    1998-09-01

    To describe the findings of magnetic resonance imaging in infectious myositis and to determine their value for differentiation between ruberculous and bacterial myositis. Magnetic resonance images of ten proven cases of infectious myositis (five tuberculous and five bacterial) were retrospectively reviewed in the light of clinical and laboratory findings. On the basis of magnetic resonance images, signal intensity of the mass, the presence or absence of an abscess, signal intensity of the peripheral wall, patterns of contrast enhancement, and associated findings were evaluated. Compared with those of bacterial myositis, the symptoms of tuberculous myositis lasted longer but there were no difinite local inflammatory signs. In three of five cases of bacterial myositis there were specific medical records;trauma in two cases and systemic lupus erythematosus in one. All tuberculous myositis cases involved a single muscle, but bacterial myositis affected multipe muscles in three cases(60%). All but one case showed a mass in the involved muscles. In one bacterial case, there was diffuse swelling in the involved muscle. On T1-weighted images, eight infectious cases showed low signal intensity;two, of the bactrerial type, showed subtle increased signal intensity. all cases demonstrated high signal intensity on t2-weighted images. The signal intensity of peripheral wall was slightly increased on T1-weighted images, but low on T2-weighted. In four cases there was associated cellulitis, and in one case each, adjacent joint effusion and deep vein thrombosis were seen. After gadolinium infusion, peripheral rim enhancement was noted in nine cases and heterogeneous enhancement in one. After magnetic resonance imaging of infectious myositis, the characteristic finding was an abscessed lesion, with the peripheral wall showing high signal intensity on T1-weighted images and low signal intensity on T2 weighted. Although we found it difficult to differentiate bacterial from tuberculous

  19. Magnetic resonance imaging of infectious myositis

    International Nuclear Information System (INIS)

    Yun, Ji Young; Kim, Jee Young; Kim, Sang Heum; Jung, Youn Ju; Cha, Eun Suk; Park, Joung Mi; Park, Young Ha

    1998-01-01

    To describe the findings of magnetic resonance imaging in infectious myositis and to determine their value for differentiation between ruberculous and bacterial myositis. Magnetic resonance images of ten proven cases of infectious myositis (five tuberculous and five bacterial) were retrospectively reviewed in the light of clinical and laboratory findings. On the basis of magnetic resonance images, signal intensity of the mass, the presence or absence of an abscess, signal intensity of the peripheral wall, patterns of contrast enhancement, and associated findings were evaluated. Compared with those of bacterial myositis, the symptoms of tuberculous myositis lasted longer but there were no difinite local inflammatory signs. In three of five cases of bacterial myositis there were specific medical records;trauma in two cases and systemic lupus erythematosus in one. All tuberculous myositis cases involved a single muscle, but bacterial myositis affected multipe muscles in three cases(60%). All but one case showed a mass in the involved muscles. In one bacterial case, there was diffuse swelling in the involved muscle. On T1-weighted images, eight infectious cases showed low signal intensity;two, of the bactrerial type, showed subtle increased signal intensity. all cases demonstrated high signal intensity on t2-weighted images. The signal intensity of peripheral wall was slightly increased on T1-weighted images, but low on T2-weighted. In four cases there was associated cellulitis, and in one case each, adjacent joint effusion and deep vein thrombosis were seen. After gadolinium infusion, peripheral rim enhancement was noted in nine cases and heterogeneous enhancement in one. After magnetic resonance imaging of infectious myositis, the characteristic finding was an abscessed lesion, with the peripheral wall showing high signal intensity on T1-weighted images and low signal intensity on T2 weighted. Although we found it difficult to differentiate bacterial from tuberculous

  20. Magnetic resonance: safety measures and biological effects

    International Nuclear Information System (INIS)

    Gordillo, I.; Lafuente, J.; Fernandez, C.; Barbero, M.J.; Cascon, E.

    1997-01-01

    The biological effects of electromagnetic fields is currently a subject of great controversy. For this reason, magnetic resonance imaging (MRI) and spectroscopy are constantly under investigation. The source of the risk in MRI is associated with the three types of electromagnetic radiation to which the patient is exposed: the static magnetic field, variable (gradient) magnetic fields and radiofrequency fields. Each is capable of producing significant biological effects when employed at sufficient intensity. Patients exposed to risk sources are those situated within the lines of force of the magnetic field, ellipsoid lines that are arranged around the magnet, representing the strength of the surrounding field. To date, at the intensity normally utilized in MRI(<2T) and respecting the field limit recommendations established by the US Food and Drug Administration (FDA) for clinical use of this technique no adverse secondary biological effects have been reported. The known biological effects and other possible secondary effects are reviewed, and the recommended safety measures are discussed. (Author)

  1. The market for magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Carlson, L.

    1990-01-01

    The medical market is, at present, the most dominant market for low T c superconductors. Indeed, without magnetic resonance imaging (MRI), there would hardly be a low T c superconductor market at all. According to the author, any development that can expand the medical market for MRI machines would be a welcome one. This paper reports how the recent advances in magnetic resonance spectroscopy (MRS) are such a development. While the principle of MRS has bee around as long as MRI, only recently have advances in technique, computer programming and magnet technology allowed MRS to advance to a point where it may become an important technology-one that could increase the medical market for superconductors. The author discussed how MRS can be used to analyze oil core samples for their oil content, oil/water ratios, how the oil is bound and how to extract it

  2. Transcranial magnetic stimulation assisted by neuronavigation of magnetic resonance images

    Science.gov (United States)

    Viesca, N. Angeline; Alcauter, S. Sarael; Barrios, A. Fernando; González, O. Jorge J.; Márquez, F. Jorge A.

    2012-10-01

    Technological advance has improved the way scientists and doctors can learn about the brain and treat different disorders. A non-invasive method used for this is Transcranial Magnetic Stimulation (TMS) based on neuron excitation by electromagnetic induction. Combining this method with functional Magnetic Resonance Images (fMRI), it is intended to improve the localization technique of cortical brain structures by designing an extracranial localization system, based on Alcauter et al. work.

  3. Magnetic resonance imaging in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.; Paprzycki, W.

    1993-01-01

    In the paper authors describe fundamental physical properties of a phenomenon of the radio-frequency excitation and relaxation of nuclei ordered in a strong magnetic field and the usefulness of MRI in medical diagnostic procedures. Basic interpretations principles of MR imaging due to signal intensity differences between organs and tissues in T 1 - and T 2 - weighted sequences and proton density are presented. Both, literature review and experience of authors suggest application of MRI in otolaryngology, it is illustrated by a lot of examples. The MR imaging studies were compared with results obtained from CT in otolaryngology field. (author)

  4. Magnetic Resonance Imaging (MRI): Lumbar Spine (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Lumbar Spine KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Lumbar Spine What's in this article? ...

  5. Magnetic resonance imaging by using nano-magnetic particles

    Energy Technology Data Exchange (ETDEWEB)

    Shokrollahi, H., E-mail: Shokrollahi@sutech.ac.ir [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Khorramdin, A. [Electroceramics Group, Department of Materials Science and Engineering, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Isapour, Gh. [Department of Materials and Engineering, Hakim Sabzevari University (Iran, Islamic Republic of)

    2014-11-15

    Magnetism and magnetic materials play a major role in various biological applications, such as magnetic bioseparation, magnetic resonance imaging (MRI), hyperthermia treatment of cancer and drug delivery. Among these techniques, MRI is a powerful method not only for diagnostic radiology but also for therapeutic medicine that utilizes a magnetic field and radio waves. Recently, this technique has contributed greatly to the promotion of the human quality life. Thus, this paper presents a short review of the physical principles and recent advances of MRI, as well as providing a summary of the synthesis methods and properties of contrast agents, like different core materials and surfactants. - Highlights: • This paper studies the physics of MRI as a powerful diagnostic technique. • MRI uses the differentiation between healthy and pathological tissues. • The relaxation times can be shortened by the use of a magnetic contrast agent. • The magnetic nanoparticles act as contrast agents, helping to increase the resolution. • Different synthesis methods can influence the magnetic resonance behavior.

  6. Flow imaging by means of nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Wedeen, V.J.; Rosen, B.R.

    1986-01-01

    To form an image (velocity profile) of fluid flowing in a vessel, the fluid is stimulated to produce a time-dependent magnetic resonance signal which is subjected to Fourier-transform. The stimulating is done so as to introduce spatially-dependent phase information indicative of the velocity profile of the fluid. Thus, for measuring velocity in the x-direction within a z-slice, after selective oxidation of the slice, a long gradient bsub(x), is applied, followed by a π pulse. A second frequency dispersing bsub(x) gradient bsub(x) is present in a period embracing the echo signal, following a phase encoding gradient bsub(y). Slice section may be omitted for projection imaging, and an image of fluid flow can be obtained by generating two data sets encoded with phase information indicative of two different velocity profiles of the fluid (taken at different times), combining the data sets, and displaying the resulting data set as an image. By analysing the signal over a period not centred at the middle of the echo signal, a frequency offset is introduced giving the image a striped appearance, the strips being curved in the presence of fluid flow. (author)

  7. Musculoskeletal applications of magnetic resonance imaging: Council on Scientific Affairs

    International Nuclear Information System (INIS)

    Harms, S.E.; Fisher, C.F.; Fulmer, J.M.

    1989-01-01

    Magnetic resonance imaging provides superior contrast, resolution, and multiplanar imaging capability, allowing excellent definition of soft-tissue and bone marrow abnormalities. For these reasons, magnetic resonance imaging has become a major diagnostic imaging method for the evaluation of many musculoskeletal disorders. The applications of magnetic resonance imaging for musculoskeletal diagnosis are summarized and examples of common clinical situations are given. General guidelines are suggested for the musculoskeletal applications of magnetic resonance imaging

  8. Nuclear magnetic resonance (NMR): principles and applications

    International Nuclear Information System (INIS)

    Quibilan, E.I.

    The basis for the phenomenon of nuclear magnetic resonance (NMR) is the ability of certain nuclei possessing both intrinsic angular momentum or ''spin'' I and magnetic moment to absorb electromagnetic energy in the radio frequency range. In principle, there are approximately 200 nuclei which may be investigated using the NMR technique. The NMR spectrum consists of intensity peaks along an axis calibrated in terms of the steady magnetic field or the frequency of the radiofrequency electromagnetic radiation. Analysis of the number, spacing, position and intensity of the lines in an NMR spectrum consists of intensity peaks along an axis calibrated in terms of the steady magnetic field or the frequency of the radiofrequency electromagnetic radiation. Analysis of the number, spacing, position and intensity of the lines in an NMR spectrum provides a variety of qualitative and quantitative analytical applications. The most obvious applications consist of the measurements of nuclear properties, such as spin number and nuclear magnetic moment. In liquids, the fine structure of resonance spectra provides a tool for chemical identification and molecular structure analysis. Other applications include the measurements of self-diffusion coefficients, magnetic fields and field homogeneity, inter-nuclear distances, and, in some cases, the water content of biological materials. (author)

  9. Nuclear magnetic resonance. Applications to medicine and biology

    International Nuclear Information System (INIS)

    Berdugo, M.; Fauchet, M.; Menasche, P.; Grall, Y.; Piwnica, A.

    1982-01-01

    Nuclear magnetic resonance (NMR) is a non-invasive exploratory technique based on a principle radically different from those of radiography, radionuclide exploration and ultrasonography. Signals coming from atomic nuclei and reflecting their density and chemical/biochemical environment are collected, thus providing information on the physiological and pathological state of tissues. The technique has multiple applications, either practical (tomographic imaging of the brain, thyroid gland and liver) or in the field of research, e.g. investigating ischaemic myocardial areas and pathological fluid composition, measuring intracellular pH, diagnosing the nature of a tumour and, broadly speaking, understanding the biochemical changes associated with malignant degeneration [fr

  10. Physics of Magnetic Resonance. Chapter 14

    Energy Technology Data Exchange (ETDEWEB)

    Song, Hee Kwon [Hospital of the University of Pennsylvania, Philadelphia (United States)

    2014-09-15

    The discovery of nuclear magnetic resonance (NMR), a property of nuclei in a magnetic field where they are able to absorb applied radiofrequency (RF) energy and subsequently release it at a specific frequency, goes back many decades to the early 1900s. Physicist Isidor I. Rabi, fascinated by the work of Otto Stern and Walther Gerlach which demonstrated that particles have intrinsic quantum properties, delved into the magnetic properties of nuclei, and in 1938 Rabi discovered the phenomenon of NMR. Several years later, in 1946, Felix Bloch and Edward Purcell refined the methods and successfully measured the NMR signal from liquids and solids. For their discoveries, Rabi received the Nobel Prize for physics in 1944 and Bloch and Purcell in 1952. While Rabi, Bloch, Purcell and other physicists working in this field had laid the foundations, a major discovery that transformed the NMR phenomenon for imaging was not made until 1973, when Paul Lauterbur developed a method for spatially encoding the NMR signal by utilizing linear magnetic field gradients. About the same time, Peter Mansfield had also discovered a means of determining the spatial structure of solids by introducing a linear gradient across the object. The idea of applying magnetic field gradients to induce spatially varying resonance frequencies to resolve the spatial distribution of magnetization was a major milestone and the beginning of magnetic resonance imaging (MRI). For their work, Lauterbur and Mansfield were awarded the Nobel Prize for medicine in 2003. Since its discovery, MRI has quickly become one of the most important medical imaging devices available to physicians today. Unlike other imaging modalities, such as X ray and computed tomography, MRI does not involve ionizing radiation. MRI also offers superior soft tissue contrast that is not possible with other imaging modalities. Furthermore, in MRI, the desired level of image contrast among different tissues can often be precisely controlled

  11. A fluid density sensor based on a resonant tube

    International Nuclear Information System (INIS)

    Zhu, Yong; Dao, Dzung Viet; Woodfield, Peter

    2014-01-01

    A fluid density sensor based on resonance frequency change of a metallic tube is presented. The sensor has been developed without using a complex micro-fabrication process. The sensor is able to identify fluid types/contaminations and improve the performance by reducing testing time, decreasing complexity of testing equipment and reducing sample sizes. The sensor can measure the resonance frequency of its own structure and determine the change in resonance frequency due to the subsequent sample inside the tube. Numerical modelling, analytical modelling and physical testing of a prototype sensor showed comparable results for both the magnitude and resonance frequency shift. The modelling results yielded a resonance frequency shift of 200 Hz from 9.87 kHz to 9.67 kHz after the water was filled into the tube. The actual testing illustrated a resonance frequency change of 280 Hz from 9.11 kHz to 8.83 kHz. The ultimate aim of the work is to determine resonance frequencies of desired samples at a level that could detect genetic disease on a cellular level. (paper)

  12. 76 FR 58281 - Magnetic Resonance Imaging Safety; Public Workshop

    Science.gov (United States)

    2011-09-20

    ...] Magnetic Resonance Imaging Safety; Public Workshop AGENCY: Food and Drug Administration, HHS. ACTION... announcing a public workshop entitled: ``Magnetic Resonance Imaging (MRI) Safety Public Workshop.'' The purpose of the public workshop is to discuss factors affecting the safe use of magnetic resonance imaging...

  13. Functional magnetic resonance imaging of the primary motor cortex ...

    Indian Academy of Sciences (India)

    Unknown

    Abbreviations used: BOLD, Blood oxygenation level dependent; CBF, cerebral blood flow; fMRI, functional magnetic resonance imaging; EPI, eco-planar imaging; FOV, field of view; MRI, Magnetic resonance imaging; MRS, magnetic resonance spectroscopy;. PET, position emission tomography; rCBF, regional cerebral ...

  14. Nuclear magnetic resonance in ferromagnetic terbium metal

    International Nuclear Information System (INIS)

    Cha, C.L.T.

    1974-01-01

    The magnetic properties of terbium were studied by the method of zero field nuclear magnetic resonance at 1.5 to 4 and 85 to 160 0 K. Two unconventional experimental techniques have been employed: the swept frequency and the swept temperature technique. Near 4 0 K, triplet resonance line structures were found and interpreted in terms of the magnetic domain and wall structures of ferromagnetic terbium. In the higher temperature range, temperature dependence of the resonance frequency and the quadrupole splitting were measured. The former provides a measurement of the temperature dependence of the magnetization M, and it agrees with bulk M measurements as well as the latest spin wave theory of M(T) (Brooks 1968). The latter agrees well with a calculation using a very general single ion density matrix for collective excitations (Callen and Shtrikman 1965). In addition, the small temperature-independent contribution to the electric field gradient at the nucleus due to the lattice and conduction electrons was untangled from the P(T) data. Also an anomalous and unexplained relaxation phenomenon was also observed

  15. [Magnetic resonance compatibility research for coronary mental stents].

    Science.gov (United States)

    Wang, Ying; Liu, Li; Wang, Shuo; Shang, Ruyao; Wang, Chunren

    2015-01-01

    The objective of this article is to research magnetic resonance compatibility for coronary mental stents, and to evaluate the magnetic resonance compatibility based on laboratory testing results. Coronary stents magnetic resonance compatibility test includes magnetically induced displacement force test, magnetically induced torque test, radio frequency induced heating and evaluation of MR image. By magnetic displacement force and torque values, temperature, and image distortion values to determine metal coronary stent demagnetization effect. The methods can be applied to test magnetic resonance compatibility for coronary mental stents and evaluate its demagnetization effect.

  16. A hyperpolarized equilibrium for magnetic resonance.

    Science.gov (United States)

    Hövener, Jan-Bernd; Schwaderlapp, Niels; Lickert, Thomas; Duckett, Simon B; Mewis, Ryan E; Highton, Louise A R; Kenny, Stephen M; Green, Gary G R; Leibfritz, Dieter; Korvink, Jan G; Hennig, Jürgen; von Elverfeldt, Dominik

    2013-01-01

    Nuclear magnetic resonance spectroscopy and imaging (MRI) play an indispensable role in science and healthcare but use only a tiny fraction of their potential. No more than ≈10 p.p.m. of all ¹H nuclei are effectively detected in a 3-Tesla clinical MRI system. Thus, a vast array of new applications lays dormant, awaiting improved sensitivity. Here we demonstrate the continuous polarization of small molecules in solution to a level that cannot be achieved in a viable magnet. The magnetization does not decay and is effectively reinitialized within seconds after being measured. This effect depends on the long-lived, entangled spin-order of parahydrogen and an exchange reaction in a low magnetic field of 10⁻³ Tesla. We demonstrate the potential of this method by fast MRI and envision the catalysis of new applications such as cancer screening or indeed low-field MRI for routine use and remote application.

  17. Study on magnetic fluid optical fiber devices for optical logic operations by characteristics of superparamagnetic nanoparticles and magnetic fluids

    International Nuclear Information System (INIS)

    Chieh, J. J.; Hong, C. Y.; Yang, S. Y.; Horng, H. E.; Yang, H. C.

    2010-01-01

    We propose two optical fiber-based schemes using two magnetic fluid optical fiber modulators in series or in parallel for optical logic signal processing and operation. Here, each magnetic fluid optical fiber modulator consists of a bare multimode fiber surrounded by magnetic fluid in which the refractive index is adjustable by applying external magnetic fields amplifying the input electrical signal to vary the transmission intensity of the optical fiber-based scheme. The physical mechanisms for the performances of the magnetic fluid optical fiber devices, such as the transmission loss related to Boolean number of the logic operation as well as the dynamic response, are studied by the characteristics of superparamagnetic nanoparticles and magnetic fluids. For example, in the dynamic response composed of the retarding and response sub-procedures except the response times of the actuation coil, the theoretical evaluation of the retarding time variation with cladding magnetic fluids length has good agreement with the experimental results.

  18. Waves on the surface of a magnetic fluid layer in a traveling magnetic field

    International Nuclear Information System (INIS)

    Zimmermann, K.; Zeidis, I.; Naletova, V.A.; Turkov, V.A.

    2004-01-01

    The plane flow of a layer of incompressible viscous magnetic fluid with constant magnetic permeability under the action of a traveling magnetic field is analyzed. The strength of the magnetic field producing a sinusoidal traveling small-amplitude wave on the surface of a magnetic fluid is found. This flow can be used in designing mobile robots

  19. Nuclear magnetic resonance imaging in pharmaceutical research

    International Nuclear Information System (INIS)

    Sarkar, S.K.

    1991-01-01

    Nuclear magnetic resonance imaging has important applications in pharmaceutical research since it allows specific tissue and disease characterization in animal models noninvasively with excellent anatomical resolution and therefore provides improved ability to monitor the efficacy of novel drugs. The utility of NMR imaging in renal studies to monitor the mechanism of drug action and renal function in rats is described. The extension of the resolution of an NMR image to microscopic domain at higher magnetic field strengths and the utility of NMR microimaging in cerebrovascular and tumour metastasis studies in mice are discussed. (author). 40 refs., 14 figs

  20. Nuclear magnetic resonance method and apparatus

    International Nuclear Information System (INIS)

    Young, I.R.

    1983-01-01

    In a method of investigating the distribution of a quantity in a chosen region of a body (E) by nuclear magnetic resonance techniques movement of the body during the investigation is monitored by probes (A, B C) (C extends orthogonally to A and B) attached to the body and responsive to magnetic fields applied to the body during the investigation. An apparatus for carrying out the method is also described. If movement is detected, due compensation may be made during processing of the collected data, or the latter may be re-ascertained after appropriate adjustment e.g. a change in the RF excitation frequency. (author)

  1. Application of a magnetic fluid seal to rotary blood pumps

    International Nuclear Information System (INIS)

    Mitamura, Y; Arioka, S; Azegami, M; Sakota, D; Sekine, K

    2008-01-01

    A magnetic fluid seal enables mechanical contact-free rotation of a shaft without frictional heat and material wear and hence has excellent durability. However, the durability of a magnetic fluid seal decreases in liquid. The life of a seal applied to a rotary blood pump is not known. We have developed a magnetic fluid seal that has a shield mechanism minimizing the influence of the rotary pump on the magnetic fluid. The developed magnetic fluid seal worked for over 286 days in a continuous flow condition, for 24 days (on-going) in a pulsatile flow condition and for 24 h (electively terminated) in blood flow. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps

  2. Proton magnetic resonance spectroscopy in the fetus.

    Science.gov (United States)

    Story, Lisa; Damodaram, Mellisa S; Allsop, Joanna M; McGuinness, Amy; Wylezinska, Marzena; Kumar, Sailesh; Rutherford, Mary A

    2011-09-01

    Magnetic Resonance Imaging (MRI) has become an established technique in fetal medicine, providing complementary information to ultrasound in studies of the brain. MRI can provide detailed structural information irrespective of the position of the fetal head or maternal habitus. Proton Magnetic Resonance Spectroscopy ((1)HMRS) is based on the same physical principles as MRI but data are collected as a spectrum, allowing the biochemical and metabolic status of in vivo tissue to be studied in a non-invasive manner. (1)HMRS has been used to assess metabolic function in the neonatal brain but fetal studies have been limited, primarily due to fetal motion. This review will assess the technique and findings from fetal studies to date. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Magnetic resonance studies of intercalation compounds

    International Nuclear Information System (INIS)

    Miller, G.R.

    1990-01-01

    During the last three or four years, nearly tow hundred papers have been published that used NMR or ESR spectroscopy to study compounds formed by the intercalation of molecules or ions into the van der Waals gap of a layered hast compound. The host lattices have ranged from the simple, such as graphite, to the complex, such as clay. In many cases, magnetic resonance techniques now enable one to obtain quite detailed information on even fairly complex intercalated species, on the nature of the changes in the host lattice accompanying intercalation, and on the nature of the interactions between the intercalant species and the host lattice. Magnetic resonance is used in conunction with many other techniques to obtain a fuller picture of these interesting systems, but this review will limit its focus to the use of NMR and ESR techniques. (author). 51 refs

  4. Sensorineural hearing loss after magnetic resonance imaging

    DEFF Research Database (Denmark)

    Mollasadeghi, Abolfazl; Mehrparvar, Amir Houshang; Atighechi, Saeid

    2013-01-01

    Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus)......). In this report, a case of bilateral sensorineural hearing loss in an otherwise healthy patient underwent brain MRI was described. The patient's hearing loss was accompanied with tinnitus and was not improved after 3 months of followup.......Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus...

  5. Magnetic resonance imaging findings in tuberculous meningoencephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Pui, M.H.; Memon, W.A. [Aga Khan Univ. Hospital, Dept. of Radiology, Karachi (Pakistan)

    2001-02-01

    To evaluate the efficacy of magnetic resonance imaging (MRI) for distinguishing tuberculosis from other types of meningoencephalitis. MRIs of 100 patients with tuberculous (50), pyogenic (33), viral (14), or fungal (3) meningoencephalitis were analyzed independently by 2 radiologists. Number, size, location, signal characteristics, surrounding edema, and contrast enhancement pattern of nodular lesions; location and pattern of meningeal enhancement; extent of infarct or encephalitis and hydrocephalus were evaluated. Contrast-enhancing nodular lesions were detected in patients with tuberculous (43 of 50 patients), pyogenic (9 of 33), and fungal (3 of 3) infections. No nodules were detected in patients with viral meningoencephalitis. Using the criteria of 1 or more solid rim or homogeneously enhancing nodules smaller than 2 cm, the sensitivity, specificity and accuracy for diagnosing tuberculous meningitis were 86.0%, 90.0% and 88.0%, respectively. Magnetic resonance imaging is useful in distinguishing tuberculous from pyogenic, viral and fungal meningoencephalitis. (author)

  6. Two-dimensional nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Bax, A.; Lerner, L.

    1986-01-01

    Great spectral simplification can be obtained by spreading the conventional one-dimensional nuclear magnetic resonance (NMR) spectrum in two independent frequency dimensions. This so-called two-dimensional NMR spectroscopy removes spectral overlap, facilitates spectral assignment, and provides a wealth of additional information. For example, conformational information related to interproton distances is available from resonance intensities in certain types of two-dimensional experiments. Another method generates 1 H NMR spectra of a preselected fragment of the molecule, suppressing resonances from other regions and greatly simplifying spectral appearance. Two-dimensional NMR spectroscopy can also be applied to the study of 13 C and 15 N, not only providing valuable connectivity information but also improving sensitivity of 13 C and 15 N detection by up to two orders of magnitude. 45 references, 10 figures

  7. Nuclear magnetic resonance - from molecules to man

    OpenAIRE

    Wüthrich, Kurt

    2017-01-01

    Initial observations of the physical phenomenon of nuclear magnetic resonance (NMR) date back to the late 1940s. In the following two decades high-resolution NMR in solution became an indispensible analytical tool in chemistry, and solid state NMR had an increasingly important role in physics. Some of the potentialities of the method for investigations of complex biological systems had also long been anticipated, and initial experiments with biological specimens were described already 30 year...

  8. OPTIMAL EXPERIMENT DESIGN FOR MAGNETIC RESONANCE FINGERPRINTING

    OpenAIRE

    Zhao, Bo; Haldar, Justin P.; Setsompop, Kawin; Wald, Lawrence L.

    2016-01-01

    Magnetic resonance (MR) fingerprinting is an emerging quantitative MR imaging technique that simultaneously acquires multiple tissue parameters in an efficient experiment. In this work, we present an estimation-theoretic framework to evaluate and design MR fingerprinting experiments. More specifically, we derive the Cram��r-Rao bound (CRB), a lower bound on the covariance of any unbiased estimator, to characterize parameter estimation for MR fingerprinting. We then formulate an optimal experi...

  9. Magnetic resonance in multiple sclerose twins

    International Nuclear Information System (INIS)

    Polman, C.H.; UitdeHaag, B.M.J.; Koetsier, C.J.; Valk, J.; Lucas, C.J.

    1989-01-01

    Magnetic resonance imaging (MR) examinations were performed in a series of 7 twin sets (4 monozygotic and 3 dizygotic) and one triplet set who were clinically discordant for multiple sclerosis (MS). MRI abnormalities were detected in a number of the unaffected members of the nonzygotic twin pairs. The authors discuss the possible implications of their findings for the present view on the aetiology of MS. (author). 3 refs.; 1 fig.; 1 tab

  10. Basic principles of nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Valk, J.; MacLean, C.; Algra, P.R.

    1985-01-01

    The intent of this book is to help clinicians understand the basic physical principles of magnetic resonance (MR) imaging. The book consists of the following: a discussion of elementary considerations; pulse sequencing; localization of MR signals in space; MR equipment; MR contrast agents; clinical applications; MR spectroscopy; and biological effects of MR imaging; a set of appendixes; and a bibliography. Illustrations and images are included

  11. BOLD magnetic resonance imaging in nephrology

    OpenAIRE

    Hall ME; Jordan JH; Juncos LA; Hundley WG; Hall JE

    2018-01-01

    Michael E Hall,1,2 Jennifer H Jordan,3 Luis A Juncos,1,2 W Gregory Hundley,3 John E Hall2 1Department of Medicine, University of Mississippi Medical Center, Jackson, MS, USA; 2Department of Physiology and Biophysics, University of Mississippi Medical Center, Jackson, MS, USA; 3Department of Internal Medicine, Section on Cardiovascular Medicine, Wake Forest University School of Medicine, Winston-Salem, NC, USA Abstract: Magnetic resonance (MR) imaging, a non-invasive modality that provides ana...

  12. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8...

  13. Sensorineural hearing loss after magnetic resonance imaging

    DEFF Research Database (Denmark)

    Mollasadeghi, Abolfazl; Mehrparvar, Amir Houshang; Atighechi, Saeid

    2013-01-01

    Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus......). In this report, a case of bilateral sensorineural hearing loss in an otherwise healthy patient underwent brain MRI was described. The patient's hearing loss was accompanied with tinnitus and was not improved after 3 months of followup....

  14. Magnetic resonance imaging in MELAS syndrome

    International Nuclear Information System (INIS)

    Rosen, L.; Phillips, S.; Enzmann, D.

    1990-01-01

    MELAS syndrome is a distinct clinical entity belonging to a group of mitochondrial encephalomyopathies characterized by the tetrad of myopathy, encephalopathy, lactic acidosis, and stroke-like episodes. Computed tomography (CT) and magnetic resonance (MR) findings are reviewed in a patient with MELAS. Serial CT studies demonstrated multiple 'migrating' infarcts in various stages of evolution involving primarily the posterior temporal and occipital regions. MR was more sensitive than CT in demonstrating the number and extent of cortical lesions in this disease entity. (orig.)

  15. Cardiac magnetic resonance imaging in clinical practice

    Directory of Open Access Journals (Sweden)

    Adriana Dias Barranhas

    2014-01-01

    Full Text Available Objective To evaluate and describe indications, mainly diagnoses and cardiac magnetic resonance imaging findings observed in clinical practice. Materials and Methods Retrospective and descriptive study of cardiac magnetic resonance performed at a private hospital and clinic in the city of Niterói, RJ, Brazil, in the period from May 2007 to April 2011. Results The sample included a total of 1000 studies performed in patients with a mean age of 53.7 ± 16.2 years and predominance for male gender (57.2%. The majority of indications were related to assessment of myocardial perfusion at rest and under pharmacological stress (507/1000; 51%, with positive results in 36.2% of them. Suspected myocarditis was the second most frequent indication (140/1000; 14%, with positive results in 63.4% of cases. These two indications were followed by study of arrhythmias (116/1000; 12%, myocardial viability (69/1000; 7% and evaluation of cardiomyopathies (47/1000; 5%. In a subanalysis, it was possible to identify that most patients were assessed on an outpatient basis (58.42%. Conclusion Cardiac magnetic resonance has been routinely performed in clinical practice, either on an outpatient or emergency/inpatient basis, and myocardial ischemia represented the main indication, followed by investigation of myocarditis, arrhythmogenic right ventricular dysplasia and myocardial viability.

  16. Image production by magnetic resonance: transparency via the atom

    International Nuclear Information System (INIS)

    Kanel, A.

    1984-01-01

    The author gives a general description of the nuclear magnetic resonance technique to study the human body. The use of superconducting magnets to generate the required magnetic field is discussed. (G.T.H.)

  17. Magnetic resonance imaging in schizophrenia: a morphometric study

    International Nuclear Information System (INIS)

    Castro, Claudio Campi de

    2001-01-01

    Thirty-three patients with chronic schizophrenia and 21 normal subjects were submitted to magnetic resonance imaging studies using a 1.5 T scanner. Axial and coronal T 2-weighted images were obtained. The volumes of the brain, intracranial, supratentorial, infratentorial and the total, ventricular and subarachnoid cerebrospinal fluid volumes were measured using semi-automated morphometric methods. The volumes of the amygdala-hippocampus complex, para hippocampal gyrus cortex, putamen, globus pallidus, temporal lobe, gray and white matter of temporal lobe were also measured. These volumes were normalized using the intracranial volume as reference. The most relevant findings observed were reduced brain volume and increased total, ventricular and subarachnoid cerebrospinal fluid volumes in patients with schizophrenia when compared to the controls. Patients with schizophrenia had also smaller amygdala-hippocampus complexes, temporal lobes and temporal lobe white matter than the controls, as well as increased putamen volumes. (author)

  18. Magnetically coupled Fano resonance of dielectric pentamer oligomer

    International Nuclear Information System (INIS)

    Zhang, Fuli; Li, Chang; He, Xuan; Chen, Lei; Fan, Yuancheng; Zhao, Qian; Zhang, Weihong; Zhou, Ji

    2017-01-01

    We present magnetically induced Fano resonance inside a dielectric metamaterial pentamer composed of ceramic bricks. Unlike previous reports where different sizes of dielectric resonators were essential to produce Fano resonance, under external magnetic field excitation, central and outer dielectric bricks with identical sizes exhibit in-phase and out-of-phase magnetic Mie oscillations. An asymmetric line shape of Fano resonance along with enhanced group delay is observed due to the interference between the magnetic resonance of the central brick and the symmetric magnetic resonance of outer bricks. Besides, Fano resonance blueshifts with the increasing resonance of the smaller central brick. The thermal-dependent permittivity of ceramics allows Fano resonance to be reversibly tuned by 300 MHz when temperature varies by 60 °C. (paper)

  19. Magnetic properties of carbonyl iron particles in magnetorheological fluids

    International Nuclear Information System (INIS)

    Gorodkin, S R; James, R O; Kordonski, W I

    2009-01-01

    Knowledge of the magnetic properties of dispersed magnetic particles is a prerequisite to the design an MR fluid with desired performance. A term specific susceptibility is introduced for characterization of particle susceptibility. The study was performed with the Bartington MS2B magnetic susceptibility system on small samples volume. Specific magnetic susceptibility of iron particles was found to be a linear function of median particle size. Structural change in the fluid, including particle organization, led to susceptibility drift and may affect fluid performance. It was shown that susceptibility data can be used for evaluation of the concentration of carbonyl iron particles in MR fluids.

  20. SQUID-detected magnetic resonance imaging in microtesla magnetic fields

    International Nuclear Information System (INIS)

    McDermott, Robert; Kelso, Nathan; Lee, SeungKyun; Moessle, Michael; Mueck, Michael; Myers, Whittier; Haken, Bernard ten; Seton, H.C.; Trabesinger, Andreas H.; Pines, Alex; Clarke, John

    2003-01-01

    We describe studies of nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance imaging (MRI) of liquid samples at room temperature in microtesla magnetic fields. The nuclear spins are prepolarized in a strong transient field. The magnetic signals generated by the precessing spins, which range in frequency from tens of Hz to several kHz, are detected by a low-transition temperature dc SQUID (Superconducting QUantum Interference Device) coupled to an untuned, superconducting flux transformer configured as an axial gradiometer. The combination of prepolarization and frequency-independent detector sensitivity results in a high signal-to-noise ratio and high spectral resolution (∼1 Hz) even in grossly inhomogeneous magnetic fields. In the NMR experiments, the high spectral resolution enables us to detect the 10-Hz splitting of the spectrum of protons due to their scalar coupling to a 31P nucleus. Furthermore, the broadband detection scheme combined with a non-resonant field-reversal spin echo allows the simultaneous observation of signals from protons and 31P nuclei, even though their NMR resonance frequencies differ by a factor of 2.5. We extend our methodology to MRI in microtesla fields, where the high spectral resolution translates into high spatial resolution. We demonstrate two-dimensional images of a mineral oil phantom and slices of peppers, with a spatial resolution of about 1 mm. We also image an intact pepper using slice selection, again with 1-mm resolution. In further experiments we demonstrate T1-contrast imaging of a water phantom, some parts of which were doped with a paramagnetic salt to reduce the longitudinal relaxation time T1. Possible applications of this MRI technique include screening for tumors and integration with existing multichannel SQUID systems for brain imaging

  1. Waveguide volume probe for magnetic resonance imaging and spectroscopy

    DEFF Research Database (Denmark)

    2015-01-01

    The present disclosure relates to a probe for use within the field of nuclear magnetic resonance, such as magnetic resonance imaging (MRI), and magnetic resonance spectroscopy (MRS)). One embodiment relates to an RF probe for magnetic resonance imaging and/or spectroscopy comprising a conductive...... non-magnetic hollow waveguide having an internal volume and at least one open end, one or more capacitors and at least a first conductive non-magnetic wire, wherein said first conductive wire connects at least one of said one or more capacitors to opposite walls of one open end of the waveguide...

  2. Diagnosing aneurysmal and unicameral bone cysts with magnetic resonance imaging.

    Science.gov (United States)

    Sullivan, R J; Meyer, J S; Dormans, J P; Davidson, R S

    1999-09-01

    The differential between aneurysmal bone cysts and unicameral bone cysts usually is clear clinically and radiographically. Occasionally there are cases in which the diagnosis is not clear. Because natural history and treatment are different, the ability to distinguish between these two entities before surgery is important. The authors reviewed, in a blinded fashion, the preoperative magnetic resonance images to investigate criteria that could be used to differentiate between the two lesions. All patients had operative or pathologic confirmation of an aneurysmal bone cyst or unicameral bone cyst. The authors analyzed the preoperative magnetic resonance images of 14 patients with diagnostically difficult bone cysts (eight children with unicameral bone cysts and six children with aneurysmal bone cysts) and correlated these findings with diagnosis after biopsy or cyst aspiration and contrast injection. The presence of a double density fluid level within the lesion strongly indicated that the lesion was an aneurysmal bone cyst, rather than a unicameral bone cyst. Other criteria that suggested the lesion was an aneurysmal bone cyst were the presence of septations within the lesion and signal characteristics of low intensity on T1 images and high intensity on T2 images. The authors identified a way of helping to differentiate between aneurysmal bone cysts and unicameral bone cysts on magnetic resonance images. Double density fluid level, septation, and low signal on T1 images and high signal on T2 images strongly suggest the bone cyst in question is an aneurysmal bone cyst, rather than a unicameral bone cyst. This may be helpful before surgery for the child who has a cystic lesion for which radiographic features do not allow a clear differentiation of unicameral bone cyst from aneurysmal bone cyst.

  3. Magnetic resonance imaging of tablet dissolution.

    Science.gov (United States)

    Nott, Kevin P

    2010-01-01

    Magnetic resonance imaging (MRI) is the technique of choice for measuring hydration, and its effects, during dissolution of tablets since it non-invasively maps (1)H nuclei associated with 'mobile' water. Although most studies have used MRI systems with high-field superconducting magnets, low-field laboratory-based instruments based on permanent magnet technology are being developed that provide key data for the formulation scientist. Incorporation of dissolution hardware, in particular the United States Pharmacopeia (USP) apparatus 4 flow-through cell, allows measurements under controlled conditions for comparison against other dissolution methods. Furthermore, simultaneous image acquisition and measurement of drug concentration allow direct comparison of the drug release throughout the hydration process. The combination of low-field MRI with USP-4 apparatus provides another tool to aid tablet formulation. Copyright 2009 Elsevier B.V. All rights reserved.

  4. Nuclear magnetic resonance studies of lipoproteins

    International Nuclear Information System (INIS)

    Hamilton, J.A.; Morrisett, J.D.

    1986-01-01

    Several nuclei in lipoproteins are magnetically active and are thus potential NMR probes of lipoprotein structure. Table I lists the magnetic isotopes preset in the covalent structures of the molecular constituents of lipoproteins: lipids, proteins, and carbohydrates. Every type of nucleus that is part of the endogenous structure of these molecules has at least one magnetic isotope. Each magnetic nucleus represents an intrinsic and completely nonperturbing probe (when at the natural abundance level) of local molecular motion and magnetic environment. The NMR experiment itself is also nonperturbing and nondestructive. Table I also lists for each nucleus its nuclear spin, its natural isotopic abundance, its sensitivity, and its resonance frequency at two commonly employed magnetic in the low field range (21.14 kG or 2.11 Tesla) and the other in the high field range (47.0 kG or 4.70 Tesla). Of the nuclei listed in Table I, /sup 1/H, /sup 13/C, and /sup 31/P have been the primary ones studied in lipoproteins. The general advantages and disadvantages afforded by these and other nuclei as probes of lipoprotein structure are discussed. /sup 13/C NMR spectroscopy, the method which has had the most extensive application (and probably has the greatest future potential) to lipoproteins, is treated in greatest detail, but many of the principles described apply to other nuclei as well

  5. Computer simulations of equilibrium magnetization and microstructure in magnetic fluids

    Science.gov (United States)

    Rosa, A. P.; Abade, G. C.; Cunha, F. R.

    2017-09-01

    In this work, Monte Carlo and Brownian Dynamics simulations are developed to compute the equilibrium magnetization of a magnetic fluid under action of a homogeneous applied magnetic field. The particles are free of inertia and modeled as hard spheres with the same diameters. Two different periodic boundary conditions are implemented: the minimum image method and Ewald summation technique by replicating a finite number of particles throughout the suspension volume. A comparison of the equilibrium magnetization resulting from the minimum image approach and Ewald sums is performed by using Monte Carlo simulations. The Monte Carlo simulations with minimum image and lattice sums are used to investigate suspension microstructure by computing the important radial pair-distribution function go(r), which measures the probability density of finding a second particle at a distance r from a reference particle. This function provides relevant information on structure formation and its anisotropy through the suspension. The numerical results of go(r) are compared with theoretical predictions based on quite a different approach in the absence of the field and dipole-dipole interactions. A very good quantitative agreement is found for a particle volume fraction of 0.15, providing a validation of the present simulations. In general, the investigated suspensions are dominated by structures like dimmer and trimmer chains with trimmers having probability to form an order of magnitude lower than dimmers. Using Monte Carlo with lattice sums, the density distribution function g2(r) is also examined. Whenever this function is different from zero, it indicates structure-anisotropy in the suspension. The dependence of the equilibrium magnetization on the applied field, the magnetic particle volume fraction, and the magnitude of the dipole-dipole magnetic interactions for both boundary conditions are explored in this work. Results show that at dilute regimes and with moderate dipole

  6. Magnetic resonance phenomena in dynamics of relativistic particles

    International Nuclear Information System (INIS)

    Ternov, I.M.; Bordovitsyn, V.A.

    1987-01-01

    A relativistic generalization of Rabi's formula for magnetic resonance is given. On this basis, we consider fast and slow passage through resonance. We define a magnetic resonance exterior field as usual, using unit vectors of a Cartesian coordinate system, a homogeneous magnetic field, and the amplitude of a rotating magnetic field. For the description of spin dynamics we use the Bargmann-Michel-Telegdi equation

  7. Dynamic rheological properties of viscoelastic magnetic fluids in uniform magnetic fields

    International Nuclear Information System (INIS)

    Yamaguchi, Hiroshi; Niu Xiaodong; Ye Xiaojiang; Li Mingjun; Iwamoto, Yuhiro

    2012-01-01

    The dynamic rheological properties of viscoelastic magnetic fluids in externally applied uniform magnetic fields are investigated by a laboratory-made cone-plate rheometer in this study. In particular, the effects of the magnetic field on the viscoelastic properties (the complex dynamic modulus) of the viscoelastic magnetic fluids are studied. In the investigation, three viscoelastic magnetic fluids are made by mixing a magnetic fluid and a viscoelastic fluid with different mass ratios. As a supplementation to the experimental investigation, a theoretical analysis is also presented. The present study shows that the viscosity and elasticity of the viscoelastic magnetic fluids are significantly influenced by the magnetic field and the concentrations of the magnetic particles in the test fluids. Theoretical analysis qualitatively explains the present findings. - Highlights: ► The dynamic rheological properties of the viscoelastic magnetic fluids in uniform magnetic fields are investigated. ► Both the magnetic field strength and the concentration of the magnetic particles in the fluids have significant effects on the viscosity and elasticity of the viscoelastic magnetic fluids. ► Theoretical prediction and analysis qualitatively explains the present findings.

  8. Nuclear resonance apparatus including means for rotating a magnetic field

    International Nuclear Information System (INIS)

    Sugimoto, H.

    1983-01-01

    A nuclear magnetic resonance apparatus including magnet apparatus for generating a homogeneous static magnetic field between its magnetic poles, shims of a magnetic substance mounted on the magnetic poles to apply a first gradient magnetic field intensity distribution in a direction orthogonal as to the direction of line of magnetic force of the static magnetic field, gradient magnetic field generating electromagnetic apparatus for generating a second gradient magnetic field having a gradient magnetic field intensity distribution in superimposition with the static magnetic field and for changing the magnetic field gradient of the first gradient magnetic field, an oscillator for generating an oscillating output having a frequency corresponding to the nuclear magnetic resonance condition of an atomic nucleus to be measured, a coil wound around a body to be examined for applying the output of said oscillator as electromagnetic waves upon the body, a receiver for detecting the nuclear magnetic resonance signals received by the coil, a gradient magnetic field controller making a magnetic field line equivalent to the combined gradient magnetic fields and for rotating the line along the section of the body to be examined by controlling said gradient magnetic field generating electromagnetic apparatus and devices for recording the nuclear magnetic resonance signals, for reconstructing the concentration distribution of the specific atomic nuclei in the section of the body, and a display unit for depicting the result of reconstruction

  9. First national meeting of magnetic resonance and hyperfine interactions

    International Nuclear Information System (INIS)

    1985-07-01

    Works performed at CNEA's: Magnetic Resonance Division; Moessbauer Spectroscopy; Solid State Physics Division; Nuclear magnetic Resonance Laboratory and Theoretical Physics Group; Mossbauer Spectroscopy Group; Nuclear Quadrupole Resonance; Physics and Materials Group; Perturbed Angular Correlation and Moessbauer Spectroscopy and Physics Department. (M.E.L.) [es

  10. The particle concentration effect on magnetic resonance linewidth for magnetic liquids with chain aggregates

    International Nuclear Information System (INIS)

    Marin, C.N.

    2002-01-01

    Based on the assumption of particle chains formation within a magnetic liquid, computer simulation of the magnetic resonance line is presented. The dependence on particle concentration within a magnetic liquid of magnetic resonance linewidth is analyzed. The computer simulation demonstrates that the particles chaining has an important effect on the enlargement of the magnetic resonance line. Increasing the particle concentration within magnetic liquid leads to an increase in the linewidth. The agreement with some experimental findings is discussed

  11. Accuracy of magnetic resonance based susceptibility measurements

    Science.gov (United States)

    Erdevig, Hannah E.; Russek, Stephen E.; Carnicka, Slavka; Stupic, Karl F.; Keenan, Kathryn E.

    2017-05-01

    Magnetic Resonance Imaging (MRI) is increasingly used to map the magnetic susceptibility of tissue to identify cerebral microbleeds associated with traumatic brain injury and pathological iron deposits associated with neurodegenerative diseases such as Parkinson's and Alzheimer's disease. Accurate measurements of susceptibility are important for determining oxygen and iron content in blood vessels and brain tissue for use in noninvasive clinical diagnosis and treatment assessments. Induced magnetic fields with amplitude on the order of 100 nT, can be detected using MRI phase images. The induced field distributions can then be inverted to obtain quantitative susceptibility maps. The focus of this research was to determine the accuracy of MRI-based susceptibility measurements using simple phantom geometries and to compare the susceptibility measurements with magnetometry measurements where SI-traceable standards are available. The susceptibilities of paramagnetic salt solutions in cylindrical containers were measured as a function of orientation relative to the static MRI field. The observed induced fields as a function of orientation of the cylinder were in good agreement with simple models. The MRI susceptibility measurements were compared with SQUID magnetometry using NIST-traceable standards. MRI can accurately measure relative magnetic susceptibilities while SQUID magnetometry measures absolute magnetic susceptibility. Given the accuracy of moment measurements of tissue mimicking samples, and the need to look at small differences in tissue properties, the use of existing NIST standard reference materials to calibrate MRI reference structures is problematic and better reference materials are required.

  12. Proton nuclear magnetic resonance studies on brain edema

    International Nuclear Information System (INIS)

    Naruse, S.; Horikawa, Y.; Tanaka, C.; Hirakawa, K.; Nishikawa, H.; Yoshizaki, K.

    1982-01-01

    The water in normal and edematous brain tissues of rats was studied by the pulse nuclear magnetic resonance (NMR) technique, measuring the longitudinal relaxation time (T1) and the transverse relaxation time (T2). In the normal brain, T1 and T2 were single components, both shorter than in pure water. Prolongation and separation of T2 into two components, one fast and one slow, were the characteristic findings in brain edema induced by both cold injury and triethyl tin (TET), although some differences between the two types of edema existed in the content of the lesion and in the degree of changes in T1 and T2 values. Quantitative analysis of T1 and T2 values in their time course relating to water content demonstrated that prolongation of T1 referred to the volume of increased water in tissues examined, and that two phases of T2 reflected the distribution and the content of the edema fluid. From the analysis of the slow component of T2 versus water content during edema formation, it was demonstrated that the increase in edema fluid was steady, and its content was constant during formation of TET-induced edema. On the contrary, during the formation of cold-injury edema, water-rich edema fluid increased during the initial few hours, and protein-rich edema fluid increased thereafter. It was concluded that proton NMR relaxation time measurements may provide new understanding in the field of brain edema research

  13. Measuring viscosity with a levitating magnet: application to complex fluids

    International Nuclear Information System (INIS)

    Even, C; Bouquet, F; Deloche, B; Remond, J

    2009-01-01

    As an experimental project proposed to students in fourth year of university, a viscometer was developed, consisting of a small magnet levitating in a viscous fluid. The viscous force acting on the magnet is directly measured: viscosities in the range 10-10 6 mPa s are obtained. This experiment is used as an introduction to complex fluids and soft matter physics

  14. Symmetry adaptation, operator equivalents and magnetic resonance

    International Nuclear Information System (INIS)

    Kibler, M.; Chatterjee, R.

    1977-12-01

    Basic quantities for symmetry adaptation are discussed in connection with molecular and solid state physics. This gives rise to a formalism whose the central elements are operator equivalents adapted to a point group. Such symmetry adapted operator equivalents are defined in terms of Schwinger operators so that they cover the off-diagonal and diagonal cases. Special emphasis is put on the applications of the formalism to magnetic resonance. More specifically, it is shown how to apply the formalism to the construction, the study of the transformation properties, and the determination of the eigenstates of a generalized spin hamiltonian. Numerous examples are given as well as key tables relative to the chain SO(3) for making easy the application of the formalism to electron paramagnetic resonance [fr

  15. Magnetic resonance imaging of valvular heart disease

    DEFF Research Database (Denmark)

    Søndergaard, Lise; Ståhlberg, F; Thomsen, C

    1999-01-01

    The optimum management of patients with valvular heart diseases requires accurate and reproducible assessment of the valvular lesion and its hemodynamic consequences. Magnetic resonance imaging (MRI) techniques, such as volume measurements, signal-void phenomena, and velocity mapping, can be used...... in an integrated approach to gain qualitative and quantitative information on valvular heart disease as well as ventricular dimensions and functions. Thus, MRI may be advantageous to the established diagnostic tools in assessing the severity of valvular heart disease as well as monitoring the lesion and predicting...... the optimal timing for valvular surgery. This paper reviews the validation of these MRI techniques in assessing valvular heart disease and discusses some typical pitfalls of the techniques, including suggestions for solutions.J. Magn. Reson. Imaging 1999;10:627-638....

  16. Nanodiamond graphitization: a magnetic resonance study

    International Nuclear Information System (INIS)

    Panich, A M; Shames, A I; Sergeev, N A; Olszewski, M; McDonough, J K; Mochalin, V N; Gogotsi, Y

    2013-01-01

    We report on the first nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR) study of the high-temperature nanodiamond-to-onion transformation. 1 H, 13 C NMR and EPR spectra of the initial nanodiamond samples and those annealed at 600, 700, 800 and 1800 ° C were measured. For the samples annealed at 600 to 800 ° C, our NMR data reveal the early stages of the surface modification, as well as a progressive increase in sp 2 carbon content with increased annealing temperature. Such quantitative experimental data were recorded for the first time. These findings correlate with EPR data on the sensitivity of the dangling bond EPR line width to air content, progressing with rising annealing temperature, that evidences consequent graphitization of the external layers of the diamond core. The sample annealed at 1800 ° C shows complete conversion of nanodiamond particles into carbon onions. (paper)

  17. Magnetic resonance tracking of fluorescent nanodiamond fabrication

    Science.gov (United States)

    Shames, A. I.; Osipov, V. Yu; Boudou, J. P.; Panich, A. M.; von Bardeleben, H. J.; Treussart, F.; Vul', A. Ya

    2015-04-01

    Magnetic resonance techniques (electron paramagnetic resonance (EPR) and nuclear magnetic resonance (NMR)) are used for tracking the multi-stage process of the fabrication of fluorescent nanodiamonds (NDs) produced by high-energy electron irradiation, annealing, and subsequent nano-milling. Pristine commercial high pressure and high temperature microdiamonds (MDs) with mean size 150 μm contain ~5  ×  1018 spins/g of singlet (S = 1/2) substitutional nitrogen defects P1, as well as sp3 C-C dangling bonds in the crystalline lattice. The half-field X-band EPR clearly shows (by the appearance of the intense ‘forbidden’ g = 4.26 line) that high-energy electron irradiation and annealing of MDs induce a large amount (~5  ×  1017 spins/g) of triplet (S = 1) magnetic centers, which are identified as negatively charged nitrogen vacancy defects (NV-). This is supported by EPR observations of the ‘allowed’ transitions between Zeeman sublevels of the triplet state. After progressive milling of the fluorescent MDs down to an ultrasubmicron scale (≤100 nm), the relative abundance of EPR active NV- defects in the resulting fluorescent NDs (FND) substantially decreases and, vice versa, the content of C-inherited singlet defects correlatively increases. In the fraction of the finest FNDs (mean particle size fingerprint of the presence of NV- centers in small ND systems. The same size reduction causes the disappearance of the characteristic hyperfine satellites in the spectra of the P1 centers. We discuss the mechanisms that cause both the strong reduction of the peak intensity of the ‘allowed’ lines in EPR spectra of triplet defects and the transformation of the P1 spectra.

  18. Molecular structure and motion in zero field magnetic resonance

    International Nuclear Information System (INIS)

    Jarvie, T.P.

    1989-10-01

    Zero field magnetic resonance is well suited for the determination of molecular structure and the study of motion in disordered materials. Experiments performed in zero applied magnetic field avoid the anisotropic broadening in high field nuclear magnetic resonance (NMR) experiments. As a result, molecular structure and subtle effects of motion are more readily observed

  19. Magnetic resonance imaging of cleft palate

    Energy Technology Data Exchange (ETDEWEB)

    Naito, Yasushi; Tasaka, Yasuyuki; Honjo, Iwao; Nishimura, Kazumasa; Nakano, Yoshihisa

    1987-03-01

    Magnetic resonance imaging (MRI) of the nasopharynx and the eustachian tube was performed in five patients with cleft palate and compared with the results of those without this anomaly. Various degrees of deformity of the eustachian tube cartilage were found in cleft palate patients. The levator veli palatini muscles were situated more laterally in cleft palate patients than in normal subjects. Also, changes in the position of these muscles after palatoplasty were clearly depicted by MRI. Besides several autopsy reports, this is the first demonstration of the characteristic anomaly around the eustachian tube by a non-invasive method.

  20. Magnetic resonance imaging of optic nerve

    International Nuclear Information System (INIS)

    Gala, Foram

    2015-01-01

    Optic nerves are the second pair of cranial nerves and are unique as they represent an extension of the central nervous system. Apart from clinical and ophthalmoscopic evaluation, imaging, especially magnetic resonance imaging (MRI), plays an important role in the complete evaluation of optic nerve and the entire visual pathway. In this pictorial essay, the authors describe segmental anatomy of the optic nerve and review the imaging findings of various conditions affecting the optic nerves. MRI allows excellent depiction of the intricate anatomy of optic nerves due to its excellent soft tissue contrast without exposure to ionizing radiation, better delineation of the entire visual pathway, and accurate evaluation of associated intracranial pathologies

  1. Magnetic resonance imaging in cardiovascular disease

    International Nuclear Information System (INIS)

    Eckel, C.G.; Mettler, F.A. Jr.; Wicks, J.D.; Stevens, G.F.

    1986-01-01

    How does magnetic resonance imaging (MRI) currently contribute in the evaluation of patients with suspected heart disease? What role will MRI play in the future in evaluation of cardiovascular disease? To understand better where MRI fits into the diagnostic algorithm of cardiovascular disease the authors first consider the characteristics that they would like to see in the ideal diagnostic test and then survey the available cardiac diagnostic tests to note the characteristics that limit or recommend a test. In the final analysis, the justification for expensive diagnostic tests such as MRI must be an overall improvement in survival or quality of life in those patients treated after diagnosis

  2. Magnetic resonance imaging of pelvic endometriosis

    International Nuclear Information System (INIS)

    Vieira, G.P.; Martin, B.; Tubiana, J.M.

    1994-01-01

    Twenty-five magnetic resonance imaging (MRI) studies were performed in 18 patients with proven endometriosis. MRI findings were analyzed and compared with laparoscopic or surgical findings; MRI accurately demonstrated ovarian endometrial cysts as well as ectopic foci of endometriosis. Adhesions may be also suggested. Contrary to laparoscopy, MRI easily depicts both deep lesions and endometrial implants under the peritoneum. Consequently, MRI appears as an useful adjunct to laparoscopy for initial diagnosis before starting a medical treatment and above all as the imaging modality of choice for evaluation of the answer to treatment, avoiding iterative and often adhesions limited laparoscopies. (author). 7 refs.; 9 figs

  3. New magnetic resonance imaging methods in nephrology

    Science.gov (United States)

    Zhang, Jeff L.; Morrell, Glen; Rusinek, Henry; Sigmund, Eric; Chandarana, Hersh; Lerman, Lilach O.; Prasad, Pottumarthi Vara; Niles, David; Artz, Nathan; Fain, Sean; Vivier, Pierre H.; Cheung, Alfred K.; Lee, Vivian S.

    2013-01-01

    Established as a method to study anatomic changes, such as renal tumors or atherosclerotic vascular disease, magnetic resonance imaging (MRI) to interrogate renal function has only recently begun to come of age. In this review, we briefly introduce some of the most important MRI techniques for renal functional imaging, and then review current findings on their use for diagnosis and monitoring of major kidney diseases. Specific applications include renovascular disease, diabetic nephropathy, renal transplants, renal masses, acute kidney injury and pediatric anomalies. With this review, we hope to encourage more collaboration between nephrologists and radiologists to accelerate the development and application of modern MRI tools in nephrology clinics. PMID:24067433

  4. Fetal magnetic resonance imaging and human genetics

    International Nuclear Information System (INIS)

    Hengstschlaeger, Markus

    2006-01-01

    The use of fetal magnetic resonance imaging (MRI), in addition to prenatal genetic testing and sonography, has the potential to improve prenatal diagnosis of genetic disorders. MRI plays an important role in the evaluation of fetal abnormalities and malformations. Fetal MRI often enables a differential diagnosis, a determination of the extent of the disorder, the prognosis, and an improvement in therapeutic management. For counseling of parents, as well as to basically understand how genetic aberrations affect fetal development, it is of great importance to correlate different genotypes with fetal MRI data

  5. Fetal magnetic resonance imaging and human genetics

    Energy Technology Data Exchange (ETDEWEB)

    Hengstschlaeger, Markus [Medical Genetics, Obstetrics and Gynecology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)]. E-mail: markus.hengstschlaeger@meduniwien.ac.at

    2006-02-15

    The use of fetal magnetic resonance imaging (MRI), in addition to prenatal genetic testing and sonography, has the potential to improve prenatal diagnosis of genetic disorders. MRI plays an important role in the evaluation of fetal abnormalities and malformations. Fetal MRI often enables a differential diagnosis, a determination of the extent of the disorder, the prognosis, and an improvement in therapeutic management. For counseling of parents, as well as to basically understand how genetic aberrations affect fetal development, it is of great importance to correlate different genotypes with fetal MRI data.

  6. Magnetic resonance in hearing loss and vertigo

    Directory of Open Access Journals (Sweden)

    Manuel Ángel MARTÍN-PÉREZ

    2017-03-01

    Full Text Available Introduction and objective: Hearing loss and vertiginous syndrome represent an important part of the otorhinolaryngology clinic. The role of the radiologist plays in their workup become fundamental. Studies using magnetic resonance imaging (MRI are essential to guide or give the diagnosis in these cases. Method: After performing a retrospective analysis of 456 MRI studies of patients with these symptoms, we conducted a review of the main pathologies recorded that can cause these symptoms. Results: We classify into vascular disorders and other variants, tumor pathology, malformations and inflammatory pathology; We also describe the most relevant findings on MRI and illustrated with examples of our center.

  7. Nuclear magnetic resonance common laboratory, quadrennial report

    International Nuclear Information System (INIS)

    1994-01-01

    This quadrennial report of the nuclear magnetic resonance common laboratory gives an overview of the main activities. Among the different described activities, only one is interesting for the INIS database: it concerns the Solid NMR of cements used for radioactive wastes storage. In this case, the NMR is used to characterize the structure of the material and the composition, structure and kinetics of formation of the alteration layer which is formed at the surface of concrete during water leaching conditions. The NMR methodology is given. (O.M.)

  8. Magnetic resonance imaging of the cardiovascular system

    International Nuclear Information System (INIS)

    Masuda, Yoshiaki; Imai, Hiroshi; Watanabe, Sigeru; Inagaki, Yoshiaki; Tateno, Yukio; Ikehira, Hiroo.

    1990-01-01

    Magnetic resonance imaging (MRI) is a new noninvasive technique for visualization of the cardiovascular system, and is used to evaluate tissue characteristics, cardiac function and blood flow abnormalities, as well as to obtain morphological information. In this paper we presented results of clinical and laboratory research obtained using conventional spin echo MRI with regard to cardiovascular anatomy, tissue characterization and physiology. Furthermore, experience with two new techniques, cine-MRI and volume-selected MR spectroscopy, and their potential clinical usefulness in detecting cardiovascular diseases are documented. (author)

  9. Nuclear magnetic resonance applications in biological systems

    International Nuclear Information System (INIS)

    Jiang Ling; Liu Maili

    2011-01-01

    Nuclear magnetic resonance (NMR) spectroscopy is a state-of-the-art technology which has been widely applied in biological systems over the past decades. It is a powerful tool for macromolecular structure determination in solution, and has the unique advantage of being capable of elucidating the structure and dynamic behavior of proteins during vital biomedical processes. In this review, we introduce the recent progress in NMR techniques for studying the structure, interaction and dynamics of proteins. The methods for NMR based drug discovery and metabonomics are also briefly introduced. (authors)

  10. Magnetic resonance imaging of the male pelvis

    International Nuclear Information System (INIS)

    Lamarque, J.L.; Rouanet, J.P.; Pujol, J.

    1986-01-01

    The authors present their preliminary results in the investigation of the male pelvis by means of a 0.35 Tesla superconductor apparatus. They present the different sequences used. The signal of the various pelvic organs in man is analysed together with the different anatomical possibilities. Magnetic resonance imaging appears to present very important advantages. The authors consider that the major limitations involve the prostate: new sequences of investigation, in particular a long TR, should be used for the purposes of tissue differentiation [fr

  11. Resonant magnetic pumping at very low frequency

    International Nuclear Information System (INIS)

    Canobbio, Ernesto

    1978-01-01

    We propose to exploit for plasma heating purposes the very low frequency limit of the Alfven wave resonance condition, which reduces essentially to safety factor q=m/n, a rational number. It is shown that a substantial fraction of the total RF-energy can be absorbed by the plasma. The lowest possible frequency value is determined by the maximum tolerable width of the RF-magnetic islands which develop near the singular surface. The obvious interest of the proposed scheme is the low frequency value (f<=10 KHz) which allows the RF-coils to be protected by stainless steel or even to be put outside the liner

  12. Proton magnetic resonance spectroscopy in schizophrenia

    International Nuclear Information System (INIS)

    Bertolino, Alessandro; Weinberger, Daniel R.

    1999-01-01

    Proton magnetic resonance spectroscopy (MRS) has become an important tool to study in vivo certain biochemical aspects of brain disorders. In the last decade this technique has been applied to the in vivo investigation of pathophysiological aspects of psychiatric disorders, extending knowledge of the related brain alterations. This review will focus on providing some background to clarify technical and biochemical issues and it will describe the studies that have been performed in schizophrenia. The results will be framed in a more general context to highlight what we have learned and what remains to be understood from the application of this technique to schizophrenia

  13. Lateral patellar luxation: magnetic resonance findings

    International Nuclear Information System (INIS)

    Armesto, V.; Pulpeiro, J.R.

    1995-01-01

    The objective of this article is to present the magnetic resonance (MR) findings associated with lateral patellar luxation. The series consisted of eight patients, all of whom presented joint effusion, damage to the medical retinaculum and cortical contusion or fracture of medical aspect of the patella or of anterolateral surface of the outer condyle. Five patients also presented patellar sub luxation. Diagnosis depends on the technique employed, with axial planes being very useful. Thus, it is recommended that they be used as the standard plane, especially in pathologies that are clinically unsuspicious as in this case. MR can also provide information that leads to surgical treatment rather than the standard conservative treatment. (Author)

  14. Indications for fetal magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Prayer, D.

    2006-01-01

    Indications to perform fetal magnetic resonance imaging (MRI) are composed of common ones related to methodological problems of ultrasound (US) assessment (such as for instance hydramnios) and special ones. The latter are related to MR capability of high-resolution soft tissue contrast and an extended field of view that allows visualization of the whole fetus, even in later stages of pregnancy. The most important indications include confirmation of US findings, work-up of malformations with respect to individual prognosis and genetic background, differentiation between acquired conditions and malformations, visualization of pathologies that have to be treated surgically immediately after birth, and morphological changes of the placenta. (orig.) [de

  15. MRCP. Magnetic resonance cholangiopancreatography; MRCP. Magnetresonanzcholangiopankreatografie

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja [Wisconsin-Madison Univ., Madison, WI (United States). Dept. of Radiology; Lauenstein, Thomas [Evangelisches Krankenhaus Duesseldorf (Germany). Radiologie

    2016-06-15

    Magnetic resonance cholangiopancreatography (MRCP) is a special MR technique to display and analyze the biliary tract and pancreatic ducts. MRCP sequences are equivalent to endoscopic retrograde cholangiopancreatography (ERCP) for diagnostic purposes due to technical developments of the classical T2 weighted MRCP sequences and the availability of contrast enhanced T1 weighted sequences. Therefore, MRCP plays a fundamental role in the diagnoses of hepatobliary and pancreatic diseases, which are presented in this review article as are technical details of sequence acquisitions and the underlying anatomy.

  16. Magnetic resonance imaging of pelvic floor dysfunction.

    Science.gov (United States)

    Lalwani, Neeraj; Moshiri, Mariam; Lee, Jean H; Bhargava, Puneet; Dighe, Manjiri K

    2013-11-01

    Pelvic floor dysfunction is largely a complex problem of multiparous and postmenopausal women and is associated with pelvic floor or organ descent. Physical examination can underestimate the extent of the dysfunction and misdiagnose the disorders. Functional magnetic resonance (MR) imaging is emerging as a promising tool to evaluate the dynamics of the pelvic floor and use for surgical triage and operative planning. This article reviews the anatomy and pathology of pelvic floor dysfunction, typical imaging findings, and the current role of functional MR imaging. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Magnetic resonance spectroscopy studies in migraine

    Energy Technology Data Exchange (ETDEWEB)

    Montagna, P.; Cortelli, P.; Barbiroli, B. (Inst. of Medical Pathology, Univ. of Bologna (Italy))

    1994-06-01

    The authors describe the method of [sup 31]phosphorus magnetic resonance spectroscopy and review the results when it is applied to the study of brain and muscle energy metabolism in migraine subjects. Brain energy metabolism appears to be abnormal in all major subtypes of migraine when measured both during and between attacks. Impaired energy metabolism is also documented in skeletal muscle. It is suggested that migraine is associated with a generalized disorder of mitochondrial oxidative phosphorylation and that this may constitute a threshold for the triggering of migraine attacks. 47 refs., 10 figs., 3 tabs.

  18. Structural magnetic resonance imaging in epilepsy

    International Nuclear Information System (INIS)

    Deblaere, Karel; Achten, Eric

    2008-01-01

    Because of its sensitivity and high tissue contrast, magnetic resonance imaging (MRI) is the technique of choice for structural imaging in epilepsy. In this review the effect of using optimised scanning protocols and the use of high field MR systems on detection sensitivity is discussed. Also, the clinical relevance of adequate imaging in patients with focal epilepsy is highlighted. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics depicted. Imaging focus will be on the diagnosis of hippocampal sclerosis and malformations of cortical development, two major causes of medically intractable focal epilepsy. (orig.)

  19. Magnetic resonance imaging of glenohumeral joint diseases

    International Nuclear Information System (INIS)

    Kieft, G.J.; Bloem, J.L.; Obermann, W.R.; Rozing, P.; Doornbos, J.

    1987-01-01

    Through the application of oblique planes and flexible surface coil techniques, magnetic resonance imaging (MRI) promises to be of great clinical value in the evaluation of a variety of pathologic conditions affecting the shoulder. In patients with joint effusions, the tendinous portion of the rotator cuff, glenoid labrum, and bicipital tendon can be readily visualized. This capability has particular relevance in patients with inflammatory disease and traumatic conditions. Rotator cuff atrophy and impingement of the coracoacromial arc upon the supraspinatus muscle and tendon can also be demonstrated. MRI is also useful in the evaluation of shoulder instability. (orig.)

  20. Structural magnetic resonance imaging in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Deblaere, Karel [Ghent University Hospital, Department of Neuroradiology, Ghent (Belgium); Ghent University Hospital, MR Department - 1K12, Ghent (Belgium); Achten, Eric [Ghent University Hospital, Department of Neuroradiology, Ghent (Belgium)

    2008-01-15

    Because of its sensitivity and high tissue contrast, magnetic resonance imaging (MRI) is the technique of choice for structural imaging in epilepsy. In this review the effect of using optimised scanning protocols and the use of high field MR systems on detection sensitivity is discussed. Also, the clinical relevance of adequate imaging in patients with focal epilepsy is highlighted. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics depicted. Imaging focus will be on the diagnosis of hippocampal sclerosis and malformations of cortical development, two major causes of medically intractable focal epilepsy. (orig.)

  1. Cardiac magnetic resonance assessment of takotsubo cardiomyopathy

    International Nuclear Information System (INIS)

    Abbas, A.; Sonnex, E.; Pereira, R.S.; Coulden, R.A.

    2016-01-01

    Takotsubo cardiomyopathy is an important condition that can be difficult to differentiate from acute coronary syndrome on the basis of clinical, electrocardiogram, and cardiac enzyme assessment alone. Although coronary angiography remains important in the acute assessment of patients with suspected takotsubo cardiomyopathy, cardiac magnetic resonance (CMR) has emerged over the last decade as an important non-invasive imaging tool in the diagnosis and follow-up of this condition. We present a review highlighting the CMR features of takotsubo cardiomyopathy and its complications with particular focus on differentiating this condition from acute myocardial infarction and myocarditis.

  2. Magnetic resonance imaging of spinal diseases

    International Nuclear Information System (INIS)

    Nakatani, Mariko; Sekiya, Toru; Harada, Junta; Kawakami, Kenji; Tada, Shimpei

    1985-01-01

    Twenty-two patients were examined to determine the clinical value of magnetic resonance imaging (MRI) in the spinal disease. Using different pulse sequences T 1 value was obtained from 38 spines; the result showed that increased T 1 value indicated spinal marrow abnormalities. A comparative study of MRI and bone scintigraphy was performed in 18 patients. Although it was not feasible to evaluate effect of therapy in metastatic disease by MRI, diffuse bone marrow disease, such as diffuse bone marrow metastases and blood dyscrasia could be detected by MRI. This limited study will suggest applicability of MRI in the spinal disease. (author)

  3. Sensorineural Hearing Loss after Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Abolfazl Mollasadeghi

    2013-01-01

    Full Text Available Magnetic resonance imaging (MRI devices produce noise, which may affect patient’s or operators’ hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus. In this report, a case of bilateral sensorineural hearing loss in an otherwise healthy patient underwent brain MRI was described. The patient’s hearing loss was accompanied with tinnitus and was not improved after 3 months of followup.

  4. Nanoplatforms for magnetic resonance imaging of cancer

    International Nuclear Information System (INIS)

    Cywinska, M. A.; Grudzinski, I. P.; Cieszanowski, A.; Bystrzejewski, M.; Poplawska, M.

    2011-01-01

    The application of biomedical nanotechnology in magnetic resonance imaging (MRI) is expect to have a major impact leading to the development of new contrast drug candidates on the nanoscale (1 - 100 nm) that are able to react with specific biological targets at a molecular level. One of the major challenges in this regard is the construction of nanomaterials, especially used in molecular MRI diagnostics of cancer in vivo, specialized antitumor drug delivery or real-time evaluation of the efficacy of the implemented cancer treatment. In this paper, we tried to gain further insights into current trends of nanomedicine, with special focus on preclinical MRI studies in translation cancer research. (authors)

  5. Nuclear magnetic resonance and medicine. Present applications

    International Nuclear Information System (INIS)

    1984-01-01

    At the workshop on nuclear magnetic resonance and medicine held at Saclay, the following topics were presented: physical principles of NMR; NMR spectroscopy signal to noise ratio; principles of NMR imaging; methods of NMR imaging; image options in NMR; biological significance of contrast in proton NMR imaging; measurement and significance of relaxation times in cancers; NMR contrast agents; NMR for in-vivo biochemistry; potential effects and hazards of NMR applications in Medicine; difficulties of NMR implantation in Hospitals; NMR imaging of brain tumors and diseases of the spinal cord; NMR and Nuclear Medicine in brain diseases [fr

  6. Cerebral fat embolism: magnetic resonance study

    International Nuclear Information System (INIS)

    Guedea, A.; Barrena, R.; Guelbenzu, S.; Tejada, A.

    1998-01-01

    We report the case of 26-year-old man who presented clinical evidence of fat embolism following a traffic accident. Although computed tomography (CT) of the brain showed no abnormalities, magnetic resonance imaging (MRI) disclosed several scattered points of high intensity on T2-weighted and proton density (PD) images, with complete resolution of the lesions on follow-up scan. MRI is considered more sensitive than computed tomography in detecting these lesions, and may be useful for their diagnosis, correlating well with the clinical course. (Author) 10 refs

  7. Developments in boron magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Schweizer, M.

    1995-01-01

    This report summarizes progress during the past year on maturing Boron-11 magnetic resonance imaging (MRI) methodology for noninvasive determination of BNCT agents (BSH) spatially in time. Three major areas are excerpted: (1) Boron-11 MRI of BSH distributions in a canine intracranial tumor model and the first human glioblastoma patient, (2) whole body Boron-11 MRI of BSH pharmacokinetics in a rat flank tumor model, and (3) penetration of gadolinium salts through the BBB as a function of tumor growth in the canine brain

  8. Magnetic resonance imaging of the pediatric airway

    International Nuclear Information System (INIS)

    Auringer, S.T.; Bisset, G.S. III; Myer, C.M.

    1991-01-01

    Evaluation of the pediatric airway is often complex and may require multiple imaging techniques and invasive procedures. We performed magnetic resonance (MR) imaging of the airway in 34 children with clinical evidence of chronic airway obstruction and compared MR findings with those obtained by surgery and/or endoscopy. MR diagnoses included vascular compression in 15 patients, primary tracheomalacic states in 12 patients, and mediastinal masses in 4 patients. Findings were normal for 3 patients. The MR findings were in agreement with the endoscopic findings in 25 to 28 cases and in agreement with the surgical findings in 21 to 21 cases. (orig./GDG)

  9. The friction control of magnetic fluid in the Couette flow

    Energy Technology Data Exchange (ETDEWEB)

    Labkovich, O.N., E-mail: olji@tut.by; Reks, A.G.; Chernobai, V.A.

    2017-06-01

    In the work characteristic areas of magnetic fluid flow are experimentally determined in the gap between the cylinders: the area of strong dipole-dipole interaction between magnetite particles 041,2. For areas with high flow losses in viscous friction is shown the possibility of reducing the introduction of magnetic fluid of carbon nanotubes and creating a rotating magnetic field. - Highlights: • Typical areas of magnetic fluid flow are determined in the gap. • Influence of dipole-dipole interaction of magnetite particles on the viscous friction. • Features of Taylor vortex flow.

  10. Clinical applications of cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Marcu, C.B.; Beek, A.M.; Van Rossum, A.C.

    2006-01-01

    Cardiovascular magnetic resonance imaging (MRI) has evolved from an effective research tool into a clinically proven, safe and comprehensive imaging modality. It provides anatomic and functional information in acquired and congenital heart disease and is the most precise technique for quantification of ventricular volumes, function and mass. Owing to its excellent interstudy reproducibility, cardiovascular MRI is the optimal method for assessment of changes in ventricular parameters after therapeutic intervention. Delayed contrast enhancement is an accurate and robust method used in the diagnosis of ischemic and nonischemic cardiomyopathies and less common diseases, such as cardiac sarcoidosis and myocarditis. First-pass magnetic contrast myocardial perfusion is becoming an alternative to radionuclide techniques for the detection of coronary atherosclerotic disease. In this review we outline the techniques used in cardiovascular MRI and discuss the most common clinical applications. (author)

  11. Parasellar meningiomas: magnetic resonance imaging findings

    International Nuclear Information System (INIS)

    Santos, Alair Augusto S.M.D. dos; Fontes, Cristina Asvolinsque P.

    2001-01-01

    We reviewed 22 cases of patients with parasellar meningiomas evaluated with magnetic resonance imaging (MRI) in private clinics of the cities of Niteroi and Rio de Janeiro, Rio de Janeiro State, Brazil. Our aim was to characterize the imaging findings in this type of tumor. MRI scanners with 0.5 and 1.0 Tesla magnets were used for the acquisition of multiplanar T1-weighted (pre-and post-gadolinium administration) and T2-weighted images. The main symptoms observed were headache and visual disturbances. Hyperprolactinaemia was observed in only one patient. The most frequent imaging finding was a parasellar mass which appeared hypointense on T1-weighted and hyperintense on T2-weighted images, and enhanced intensively after gadolinium administration. MRI is useful to demonstrate the lesion and to asses the damage to adjacent structures, particularly when the patient presents visual disturbances due to involvement of the cavernous sinuses. (author)

  12. Magnetic resonance imaging of parotid tumors, 1

    International Nuclear Information System (INIS)

    Nakamura, Akihiko; Yamashita, Toshio; Inoue, Toshiya; Kumazawa, Tadami; Kato, Tsutomu; Sawada, Satoshi; Tanaka, Yoshimasa

    1987-01-01

    We compared the usefulness of magnetic resonance imaging (MRI), with that of X-ray computed tomography in the preoperative diagnosis of parotid tumors. We performed in 13 patients with parotid tumors and 10 of them were operated. The MRI equipment had a magnetic fild of 0.15 Tesla. We used the spine echo acquisition technique and a repetition time of 600, 1000 and 2000 milli-seconds, and echo time of 40 and 80 milli-seconds. We found that the T 1 weighted image well visualized the duct of the parotid gland, the T 2 weighted image provided fine pictures of the parotid tumor. The facial nerve of normal parotid glands could not be visualized by MRI. (author)

  13. Contrast Agent in Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Vu-Quang, Hieu

    2015-01-01

    Nanoparticles have been employed as contrast agent in magnetic resonance imaging (MRI) in order to improve sensitivity and accuracy in diagnosis. In addition, these contrast agents are potentially combined with other therapeutic compounds or near infrared bio-imaging (NIR) fluorophores to obtain...... theranostic or dual imaging purposes, respectively. There were two main types of MRI contrast agent that were synthesized during this PhD project including fluorine containing nanoparticles and magnetic nanoparticles. In regard of fluorine containing nanoparticles, there were two types contrast agent...... cancer cells for cancer diagnosis in MRI. F127-Folate coated SPION were stable in various types of suspension medium for over six months. They could specifically target folate receptor of cancer cells in vitro and in vivo thus enhancing the contrast in MRI T2/T2* weighted images. These are preliminary...

  14. Shimadzu magnetic resonance imaging system, SMT-50

    International Nuclear Information System (INIS)

    Oikawa, Shiro; Nishida, Takayuki; Fujio, Yasuo

    1986-01-01

    The magnetic resonance imaging (MRI) system, as a new modality of medical imaging, has already been put to practical applications on many clinical sites, through which a lot of clinical data has been accumulated. It can offer a powerful new probe of internal anatomy of the human body and its functions. Now that the MRI has established its effectiveness in diagnosis, a really practical MRI system which features high efficiency and economical design with high patient throughput is strongly called for. Introduced in this article is a superconductive magnet MRI system, SMT-50, operating at 5000 Gauss. It has realized an excellent diagnostic capability with such functions as multi-slice multi-echo imaging, high sensitive, surface coil technique and so on. High resolution image display (1024 x 1024 pixcel) unit and separate console system (viewing console and scanning console) will assist high patient throughput. The outline of the SMT-50 and its clinical data are reported here. (author)

  15. Preoperative conventional magnetic resonance images versus magnetic resonance arthrography of subacromial impingement syndrome

    International Nuclear Information System (INIS)

    Ahn, Sang Hyuk; Park, Jung Hwan; Moon, Tae Yong; Lee, In Sook; Lee, Seung Jun

    2012-01-01

    To evaluate the usefulness of conventional magnetic resonance images (MRI) for arthroscopic surgery in subacromial impingement syndrome of the shoulder, as an alternative to MR arthrography with additional T2 fat saturation images (MRA). The preoperative MRI of 77 patients (45 females, 32 males) (52 right, 25 left) and MRA of 34 patients (14 females, 20 males) (24 right, 10 left) with subsequent arthroscopic confirmation of subacromial impingement syndrome were reviewed retrospectively. The lesions requiring arthroscopic surgery were 95 subacromial spurs, 101 subacromial bursitis, and 51 full-thickness and 44 partial thickness tears of the supraspinatus among 111 cases for both studies. A two by two table was constructed in order to calculate the sensitivity and specificity of both studies against arthroscopic outcomes. Also we analyzed the false positive and false negative cases of the full-thickness tears individually. The detection rates of subacromial spur and bursitis and full and partial thickness tears of the supraspinatus were 91%, 94%, 77%, and 65% in MRI and 93%, 100%, 83%, and 77% in MRA respectively. Their specificities were 33%, 33%, 90%, and 76% in MRI and 50%, 75%, 100%, and 71% in MRA respectively. Eleven false negative cases in regards to MRI resulted in Ellman's grade 3 partial thickness tear (72.7%), mild bursitis (63.6%), greater tuberosity erosion (45.5%), and negative fluid signal of the glenohumeral joint (81.8%). Three false positive cases on the MRI were induced from errors with lower window depth and width on the imagings. Two false negative cases on MRA were induced from the adhesion between Ellman's grade 3 rim rent tear and the glenohumeral joint cavity. Conventional MR images could be used to decide the arthroscopic surgery in subacromial impingement syndrome, as an alternative to MR arthrography with additional T2 fat saturation images

  16. Preoperative conventional magnetic resonance images versus magnetic resonance arthrography of subacromial impingement syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sang Hyuk; Park, Jung Hwan; Moon, Tae Yong [Pusan National Univ. Yangsan Hospital, Yangsan (Korea, Republic of); Lee, In Sook; Lee, Seung Jun [Pusan National Univ. Hospital, Busan (Korea, Republic of)

    2012-09-15

    To evaluate the usefulness of conventional magnetic resonance images (MRI) for arthroscopic surgery in subacromial impingement syndrome of the shoulder, as an alternative to MR arthrography with additional T2 fat saturation images (MRA). The preoperative MRI of 77 patients (45 females, 32 males) (52 right, 25 left) and MRA of 34 patients (14 females, 20 males) (24 right, 10 left) with subsequent arthroscopic confirmation of subacromial impingement syndrome were reviewed retrospectively. The lesions requiring arthroscopic surgery were 95 subacromial spurs, 101 subacromial bursitis, and 51 full-thickness and 44 partial thickness tears of the supraspinatus among 111 cases for both studies. A two by two table was constructed in order to calculate the sensitivity and specificity of both studies against arthroscopic outcomes. Also we analyzed the false positive and false negative cases of the full-thickness tears individually. The detection rates of subacromial spur and bursitis and full and partial thickness tears of the supraspinatus were 91%, 94%, 77%, and 65% in MRI and 93%, 100%, 83%, and 77% in MRA respectively. Their specificities were 33%, 33%, 90%, and 76% in MRI and 50%, 75%, 100%, and 71% in MRA respectively. Eleven false negative cases in regards to MRI resulted in Ellman's grade 3 partial thickness tear (72.7%), mild bursitis (63.6%), greater tuberosity erosion (45.5%), and negative fluid signal of the glenohumeral joint (81.8%). Three false positive cases on the MRI were induced from errors with lower window depth and width on the imagings. Two false negative cases on MRA were induced from the adhesion between Ellman's grade 3 rim rent tear and the glenohumeral joint cavity. Conventional MR images could be used to decide the arthroscopic surgery in subacromial impingement syndrome, as an alternative to MR arthrography with additional T2 fat saturation images.

  17. Energy dissipation in a finite volume of magnetic fluid

    Energy Technology Data Exchange (ETDEWEB)

    Bashtovoi, V.; Motsar, A.; Reks, A., E-mail: alexfx20@yandex.ru

    2017-06-01

    This study is devoted to investigation of energy dissipation processes which happen in a magnetic fluid drop with compound magnet during its motion in cylindrical non magnetic container. The possibility of energy dissipation control by means of electromagnetic field is examined. It's found that a change of magnetic field of compound magnet can lead to both increase and decrease of oscillation decay time and relative damping factor can be varied in a range of ±35%.

  18. Performances of Magnetic Fluid Seal and Application to Turbopumps

    OpenAIRE

    北洞, 貴也; 黒川, 淳一; 宮副, 雄貴; 林, 正悦

    1994-01-01

    A magnetic fluid shaft seal can achieve zero-leakage and operate stably against shaft vibration, but the sealing pressure is very low. In order to improve the pressure performance of a magnetic fluid seal and apply it to a turbopump, the seal pressure characteristics are studied theoretically and experimentally. The Poisson equation for magnetic vector potential is solved by FEM, and the seal performances are determined by use of the Bernoulli equation. The validity of the theory is confirmed...

  19. Pulse sequences for contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Graves, Martin J.

    2007-01-01

    The theory and application of magnetic resonance imaging (MRI) pulse sequences following the administration of an exogenous contrast agent are discussed. Pulse sequences are categorised according to the contrast agent mechanism: changes in proton density, relaxivity, magnetic susceptibility and resonant frequency shift. Applications in morphological imaging, magnetic resonance angiography, dynamic imaging and cell labelling are described. The importance of optimising the pulse sequence for each application is emphasised

  20. Deep-level defects in semiconductors: studies by magnetic resonance

    International Nuclear Information System (INIS)

    Ammerlaan, C.A.J.

    1983-01-01

    This work is divided into two parts. In the first one, the following topics are discussed: paramagnetic centers in semiconductors, principles of magnetic resonance, spin-Hamiltonian, g-tensor, hyperfine interaction, magnetic resonance spectrometer. In the second part it is dicussed defects studied by magnetic resonance including vacancy and divacancy in silicon, iron in silicon, nitrogen in diamond and antisite defects in III-V compounds. (A.C.A.S.) [pt

  1. Magnetic resonance imaging of the central nervous system

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Norman, D.

    1987-01-01

    This book presents the papers on technological advancement and diagnostic uses g magnetic resonance imaging. A comparative evaluation with computerized tomography is presented. Topics covered are imaging principles g magnetic resonance;instrumentation of magnetic resonance (MR);pathophysiology;quality and limitations g images;NMR imaging of brain and spinal cord;MR spectroscopy and its applications;neuroanatomy;Congenital malformations of brain and MR imaging;planning g MR imaging of spine and head and neck imaging

  2. Magnetic resonance imaging of the bone marrow

    International Nuclear Information System (INIS)

    Baur-Melnyk, Andrea

    2013-01-01

    The first book devoted to MRI of the bone marrow. Describes the MRI appearances of normal bone marrows and the full range of bone marrow disorders. Discusses the role of advanced MRI techniques and contrast enhancement. On account of its unrivalled imaging capabilities and sensitivity, magnetic resonance imaging (MRI) is considered the modality of choice for the investigation of physiologic and pathologic processes affecting the bone marrow. This book describes the MRI appearances of both the normal bone marrow, including variants, and the full range of bone marrow disorders. Detailed discussion is devoted to malignancies, including multiple myeloma, lymphoma, chronic myeloproliferative disorders, leukemia, and bone metastases. Among the other conditions covered are benign and malignant compression fractures, osteonecrosis, hemolytic anemia, Gaucher's disease, bone marrow edema syndrome, trauma, and infective and non-infective inflammatory disease. Further chapters address the role of MRI in assessing treatment response, the use of contrast media, and advanced MRI techniques. Magnetic Resonance Imaging of the Bone Marrow represents an ideal reference for both novice and experienced practitioners.

  3. Nuclear magnetic resonance in cardiology: cardiac MRI

    International Nuclear Information System (INIS)

    Fernandez, Claudio C.

    2003-01-01

    As a new gold standard for mass, volume and flow, the magnetic resonance imaging (MRI) is probably the most rapidly evolving technique in the cardiovascular diagnosis. An integrated cardiac MRI examination allows the evaluation of morphology, global and regional function, coronary anatomy, perfusion, viability and myocardial metabolism, all of them in only one diagnostic test and in a totally noninvasive manner. The surgeons can obtain relevant information on all aspects of diseases of the heart and great vessels, which include anatomical details and relationships with the greatest field of view, and may help to reduce the number of invasive procedures required in pre and postoperative evaluation. However, despite these excellent advantages the present clinical utilization of MRI is still too often restricted to few pathologies or case studies in which other techniques fail to identify the cardiac or cardiovascular abnormalities. If magnetic resonance is an excellent method for diagnosing so many different cardiac conditions, why is so little it used in routine cardiac practice? Cardiologists are still not very familiar with the huge possibilities or cardiovascular MRI utilities. Our intention is to give a comprehensive survey of many of the clinical applications of this challenger technique in the study of the heart and great vessels. Those who continue to ignore this important and mature imaging technique will rightly fail to benefit. (author) [es

  4. Magnetic Resonance Imaging of Liver Metastasis.

    Science.gov (United States)

    Karaosmanoglu, Ali Devrim; Onur, Mehmet Ruhi; Ozmen, Mustafa Nasuh; Akata, Deniz; Karcaaltincaba, Musturay

    2016-12-01

    Liver magnetic resonance imaging (MRI) is becoming the gold standard in liver metastasis detection and treatment response assessment. The most sensitive magnetic resonance sequences are diffusion-weighted images and hepatobiliary phase images after Gd-EOB-DTPA. Peripheral ring enhancement, diffusion restriction, and hypointensity on hepatobiliary phase images are hallmarks of liver metastases. In patients with normal ultrasonography, computed tomography (CT), and positron emission tomography (PET)-CT findings and high clinical suspicion of metastasis, MRI should be performed for diagnosis of unseen metastasis. In melanoma, colon cancer, and neuroendocrine tumor metastases, MRI allows confident diagnosis of treatment-related changes in liver and enables differential diagnosis from primary liver tumors. Focal nodular hyperplasia-like nodules in patients who received platinum-based chemotherapy, hypersteatosis, and focal fat can mimic metastasis. In cancer patients with fatty liver, MRI should be preferred to CT. Although the first-line imaging for metastases is CT, MRI can be used as a problem-solving method. MRI may be used as the first-line method in patients who would undergo curative surgery or metastatectomy. Current limitation of MRI is low sensitivity for metastasis smaller than 3mm. MRI fingerprinting, glucoCEST MRI, and PET-MRI may allow simpler and more sensitive diagnosis of liver metastasis. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Smart Contrast Agents for Magnetic Resonance Imaging.

    Science.gov (United States)

    Bonnet, Célia S; Tóth, Éva

    2016-01-01

    By visualizing bioactive molecules or biological parameters in vivo, molecular imaging is searching for information at the molecular level in living organisms. In addition to contributing to earlier and more personalized diagnosis in medicine, it also helps understand and rationalize the molecular factors underlying physiological and pathological processes. In magnetic resonance imaging (MRI), complexes of paramagnetic metal ions, mostly lanthanides, are commonly used to enhance the intrinsic image contrast. They rely either on the relaxation effect of these metal chelates (T(1) agents), or on the phenomenon of paramagnetic chemical exchange saturation transfer (PARACEST agents). In both cases, responsive molecular magnetic resonance imaging probes can be designed to report on various biomarkers of biological interest. In this context, we review recent work in the literature and from our group on responsive T(1) and PARACEST MRI agents for the detection of biogenic metal ions (such as calcium or zinc), enzymatic activities, or neurotransmitter release. These examples illustrate the general strategies that can be applied to create molecular imaging agents with an MRI detectable response to biologically relevant parameters.

  6. Magnetic resonance spectroscopy: clinical application in neuroradiology

    International Nuclear Information System (INIS)

    Penev, L.

    2012-01-01

    Full text: Magnetic Resonance Spectroscopy (MRS) provides a non-invasive method of studying metabolism in vivo. Magnetic resonance spectroscopy (MRS) defines neuro chemistry on a regional basis by acquiring a radiofrequency signal with chemical shift from one or many voxels or volumes previously selected on MRI. The tissue's chemical environment determines the frequency of a metabolite peak in an MRS spectrum. Candidates for MRS include: 1 H, 31 P, 13 C, 23 Na, 7 Li, 19 F, 14 N, 15 N, 17 O, 39 K The most commonly studied nuclei are 1 H and 31 P. This lecture is focused on Proton ( 1 H) Spectroscopy. Proton MRS can be added on to conventional MR imaging protocols. It can be used to serially monitor biochemical changes in tumors, stroke, epilepsy, metabolic disorders, infections, and neurodegenerative diseases.The MR spectra do not come labeled with diagnoses. They require interpretation and should always be correlated with the MR images before making a final diagnosis. As a general rule, the single voxel, short TE technique is used to make the initial diagnosis, because the signal-to-noise is high and all metabolites are represented. Multi-voxel, long TE techniques are used to further characterize different regions of a mass and to assess brain parenchyma around or adjacent to the mass. Multi-voxel, long TE techniques are also used to assess response to therapy and to search for tumor recurrence. Each metabolite appears at a specific ppm, and each one reflects specific cellular and biochemical processes

  7. [Surface coils for magnetic-resonance images].

    Science.gov (United States)

    Rodríguez-González, Alfredo Odón; Amador-Baheza, Ricardo; Rojas-Jasso, Rafael; Barrios-Alvarez, Fernando Alejandro

    2005-01-01

    Since the introduction of magnetic resonance imaging in Mexico, the development of this important medical imaging technology has been almost non-existing in our country. The very first surface coil prototypes for clinical applications in magnetic resonance imaging has been developed at the Center of Research in Medical Imaging and Instrumentation of the Universidad Autónoma Metropolitana Iztapalapa (Metropolitan Autonomous University, Campus Iztapalapa). Two surface coil prototypes were built: a) a circular-shaped coil and b) a square-shaped coil for multiple regions of the body, such as heart, brain, knee, hands, and ankles. These coils were tested on the 1.5T imager of the ABC Hospital-Tacubaya, located in Mexico City. Brain images of healthy volunteers were obtained in different orientations: sagittal, coronal, and axial. Since images showed a good-enough clinical quality for diagnosis, it is fair to say that these coil prototypes can be used in the clinical environment, and with small modifications, they can be made compatible with almost any commercial scanner. This type of development can offer new alternatives for further collaboration between the research centers and the radiology community, in the search of new applications and developments of this imaging technique.

  8. Magnetic resonance imaging findings in adnexial torsion

    Energy Technology Data Exchange (ETDEWEB)

    Trindade, Ronald Meira Castro; Quadros, Marianne Siquara de [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Instituto de Ensino e Pesquisa], e-mail: rtrindade@einstein.br; Baroni, Ronaldo Hueb; Rosemberg, Michelle; Racy, Marcelo de Castro Jorge; Tachibana, Adriano [Hospital Albert Einstein, Sao Paulo, SP (Brazil); Funari, Marcelo Buarque de Gusmao [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Imaging Service

    2010-01-15

    Adnexial torsion is an unusual event, but a major cause of abdominal pain in women. It is often associated with ovarian tumor or cyst, but can occur in normal ovaries, especially in children. The twisting of adnexial structures may involve the ovary or tube, but frequently affects both. In most cases, it is unilateral, with slight predilection for the right size. In imaging findings, increased ovarian volume and adnexial masses are observed, with reduced or absent vascularisation. In cases of undiagnosed or untreated complete twist, hemorrhagic necrosis may occur leading to complications; in that, peritonitis is the most frequent. Early diagnosis helps preventing irreversible damage with conservative treatment, thereby saving the ovary. Limitations in performing physical examination, possible inconclusive results in ultrasound and exposure to radiation in computed tomography makes magnetic resonance imaging a valuable tool in emergency assessment of gynecological diseases. The objective of this study was to report two confirmed cases of adnexial twist, emphasizing the contribution of magnetic resonance imaging in the diagnosis of this condition. (author)

  9. Magnetic Resonance Imaging Evaluation of Cardiac Masses

    International Nuclear Information System (INIS)

    Braggion-Santos, Maria Fernanda; Koenigkam-Santos, Marcel; Teixeira, Sara Reis; Volpe, Gustavo Jardim; Trad, Henrique Simão; Schmidt, André

    2013-01-01

    Cardiac tumors are extremely rare; however, when there is clinical suspicion, proper diagnostic evaluation is necessary to plan the most appropriate treatment. In this context, cardiovascular magnetic resonance imaging (CMRI) plays an important role, allowing a comprehensive characterization of such lesions. To review cases referred to a CMRI Department for investigation of cardiac and paracardiac masses. To describe the positive case series with a brief review of the literature for each type of lesion and the role of cardiovascular magnetic resonance imaging in evaluation. Between August 2008 and December 2011, all cases referred for CMRI with suspicion of tumor involving the heart were reviewed. Cases with positive histopathological diagnosis, clinical evolution or therapeutic response compatible with the clinical suspicion and imaging findings were selected. Among the 13 cases included in our study, eight (62%) had histopathological confirmation. We describe five benign tumors (myxomas, rhabdomyoma and fibromas), five malignancies (sarcoma, lymphoma, Richter syndrome involving the heart and metastatic disease) and three non-neoplastic lesions (pericardial cyst, intracardiac thrombus and infectious vegetation). CMRI plays an important role in the evaluation of cardiac masses of non-neoplastic and neoplastic origin, contributing to a more accurate diagnosis in a noninvasive manner and assisting in treatment planning, allowing safe clinical follow-up with good reproducibility

  10. Magnetic resonance spectroscopy as an imaging method

    International Nuclear Information System (INIS)

    Bomsdorf, H.; Imme, M.; Jensen, D.; Kunz, D.; Menhardt, W.; Ottenberg, K.; Roeschmann, P.; Schmidt, K.H.; Tschendel, O.; Wieland, J.

    1990-01-01

    An experimental Magnetic Resonance (MR) system with 4 tesla flux density was set up. For that purpose a data acquisition system and RF coils for resonance frequencies up to 170 MHz were developed. Methods for image guided spectroscopy as well as spectroscopic imaging focussing on the nuclei 1 H and 13 C were developed and tested on volunteers and selected patients. The advantages of the high field strength with respect to spectroscopic studies were demonstrated. Developments of a new fast imaging technique for the acquisition of scout images as well as a method for mapping and displaying the magnetic field inhomogeneity in-vivo represent contributions to the optimisation of the experimental procedure in spectroscopic studies. Investigations on the interaction of RF radiation with the exposed tissue allowed conclusions regarding the applicability of MR methods at high field strengths. Methods for display and processing of multi-dimensional spectroscopic imaging data sets were developed and existing methods for real-time image synthesis were extended. Results achieved in the field of computer aided analysis of MR images comprised new techniques for image background detection, contour detection and automatic image interpretation as well as knowledge bases for textural representation of medical knowledge for diagnosis. (orig.) With 82 refs., 3 tabs., 75 figs [de

  11. Magnetic resonance imaging of the bone marrow

    Energy Technology Data Exchange (ETDEWEB)

    Baur-Melnyk, Andrea (ed.) [Klinikum der Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2013-08-01

    The first book devoted to MRI of the bone marrow. Describes the MRI appearances of normal bone marrows and the full range of bone marrow disorders. Discusses the role of advanced MRI techniques and contrast enhancement. On account of its unrivalled imaging capabilities and sensitivity, magnetic resonance imaging (MRI) is considered the modality of choice for the investigation of physiologic and pathologic processes affecting the bone marrow. This book describes the MRI appearances of both the normal bone marrow, including variants, and the full range of bone marrow disorders. Detailed discussion is devoted to malignancies, including multiple myeloma, lymphoma, chronic myeloproliferative disorders, leukemia, and bone metastases. Among the other conditions covered are benign and malignant compression fractures, osteonecrosis, hemolytic anemia, Gaucher's disease, bone marrow edema syndrome, trauma, and infective and non-infective inflammatory disease. Further chapters address the role of MRI in assessing treatment response, the use of contrast media, and advanced MRI techniques. Magnetic Resonance Imaging of the Bone Marrow represents an ideal reference for both novice and experienced practitioners.

  12. Ultra-fast magnetic resonance encephalography of physiological brain activity - Glymphatic pulsation mechanisms?

    Science.gov (United States)

    Kiviniemi, Vesa; Wang, Xindi; Korhonen, Vesa; Keinänen, Tuija; Tuovinen, Timo; Autio, Joonas; LeVan, Pierre; Keilholz, Shella; Zang, Yu-Feng; Hennig, Jürgen; Nedergaard, Maiken

    2016-06-01

    The theory on the glymphatic convection mechanism of cerebrospinal fluid holds that cardiac pulsations in part pump cerebrospinal fluid from the peri-arterial spaces through the extracellular tissue into the peri-venous spaces facilitated by aquaporin water channels. Since cardiac pulses cannot be the sole mechanism of glymphatic propulsion, we searched for additional cerebrospinal fluid pulsations in the human brain with ultra-fast magnetic resonance encephalography. We detected three types of physiological mechanisms affecting cerebral cerebrospinal fluid pulsations: cardiac, respiratory, and very low frequency pulsations. The cardiac pulsations induce a negative magnetic resonance encephalography signal change in peri-arterial regions that extends centrifugally and covers the brain in ≈1 Hz cycles. The respiratory ≈0.3 Hz pulsations are centripetal periodical pulses that occur dominantly in peri-venous areas. The third type of pulsation was very low frequency (VLF 0.001-0.023 Hz) and low frequency (LF 0.023-0.73 Hz) waves that both propagate with unique spatiotemporal patterns. Our findings using critically sampled magnetic resonance encephalography open a new view into cerebral fluid dynamics. Since glymphatic system failure may precede protein accumulations in diseases such as Alzheimer's dementia, this methodological advance offers a novel approach to image brain fluid dynamics that potentially can enable early detection and intervention in neurodegenerative diseases. © The Author(s) 2015.

  13. Reciprocity and gyrotropism in magnetic resonance transduction

    International Nuclear Information System (INIS)

    Tropp, James

    2006-01-01

    We give formulas for transduction in magnetic resonance - i.e., the appearance of an emf due to Larmor precession of spins - based upon the modified Lorentz reciprocity principle for gyrotropic (also called 'nonreciprocal') media, i.e., in which a susceptibility tensor is carried to its transpose by reversal of an external static field [cf., R. F. Harrington and A. T. Villeneuve IRE Trans. Microwave Theory and Technique MTT6, 308 (1958)]. Prior applications of reciprocity to magnetic resonance, despite much success, have ignored the gyrotropism which necessarily arises due to nuclear and/or unpaired electronic spins. For detection with linearly polarized fields, oscillating at the Larmor frequency, the emf is written in terms of a volume integral containing a product of two factors which we define as the antenna patterns, i.e. (H 1x ±iH 1y ), where, e.g., for a single transceive antenna, the H's are just the spatially dependent oscillatory magnetic field strengths, per the application of some reference current at the antenna terminals, with the negative sign obtaining for transmission, and the positive for reception. Similar expressions hold for separate transmit and receive antennas; expressions are also given for circular polarization of the fields. We then exhibit a receive-only array antenna of two elements for magnetic resonance imaging of protons, which, due an intensity artifact arising from stray reactive coupling of the elements, produces, despite its own bilateral symmetry, asymmetric proton NMR images of a symmetric cylindrical phantom containing aqueous saline solution [J. Tropp and T. Schirmer, J. Magn. Reson. 151, 146 (2001)]. Modification of this two-port antenna, to function in transmit-receive mode, allows us to demonstrate highly nonreciprocal behavior: that is, to record images (of cylindrical test phantoms containing aqueous saline solution) whose appearance dramatically changes, when the roles of transmission and reception are swapped between

  14. Proceedings of the nuclear magnetic resonance user meeting

    International Nuclear Information System (INIS)

    1987-01-01

    Studies on utilization of nuclear magnetic resonance, such as: chemical analysis in complexes and organic compounds; structures and magnetic properties of solids; construction of images and; spectrometer designs, are presented. (M.C.K.) [pt

  15. Resonance of magnetization excited by voltage in magnetoelectric heterostructures

    Science.gov (United States)

    Yu, Guoliang; Zhang, Huaiwu; Li, Yuanxun; Li, Jie; Zhang, Dainan; Sun, Nian

    2018-04-01

    Manipulation of magnetization dynamics is critical for spin-based devices. Voltage driven magnetization resonance is promising for realizing low-power information processing systems. Here, we show through Finite Element Method (FEM) simulations that magnetization resonance in nanoscale magnetic elements can be generated by a radio frequency (rf) voltage via the converse magnetoelectric (ME) effect. The magnetization dynamics induced by voltage in a ME heterostructures is simulated by taking into account the magnetoelastic and piezoelectric coupling mechanisms among magnetization, strain and voltage. The frequency of the excited magnetization resonance is equal to the driving rf voltage frequency. The proposed voltage driven magnetization resonance excitation mechanism opens a way toward energy-efficient spin based device applications.

  16. Chiral discrimination in nuclear magnetic resonance spectroscopy

    Science.gov (United States)

    Lazzeretti, Paolo

    2017-11-01

    Chirality is a fundamental property of molecules whose spatial symmetry is characterized by the absence of improper rotations, making them not superimposable to their mirror image. Chiral molecules constitute the elementary building blocks of living species and one enantiomer is favoured in general (e.g. L-aminoacids and D-sugars pervade terrestrial homochiral biochemistry) because most chemical reactions producing natural substances are enantioselective. Since the effect of chiral chemicals and drugs on living beings can be markedly different between enantiomers, the quest for practical spectroscopical methods to scrutinize chirality is an issue of great importance and interest. Nuclear magnetic resonance (NMR) is a topmost analytical technique, but spectrometers currently used are ‘blind’ to chirality, i.e. unable to discriminate the two mirror-image forms of a chiral molecule, because, in the absence of a chiral solvent, the spectral parameters, chemical shifts and spin-spin coupling constants are identical for enantiomers. Therefore, the development of new procedures for routine chiral recognition would offer basic support to scientists. However, in the presence of magnetic fields, a distinction between true and false chirality is mandatory. The former epitomizes natural optical activity, which is rationalized by a time-even pseudoscalar, i.e. the trace of a second-rank tensor, the mixed electric dipole/magnetic dipole polarizability. The Faraday effect, magnetic circular dichroism and magnetic optical activity are instead related to a time-odd axial vector. The present review summarizes recent theoretical and experimental efforts to discriminate enantiomers via NMR spectroscopy, with the focus on the deep connection between chirality and symmetry properties under the combined set of fundamental discrete operations, namely charge conjugation, parity (space inversion) and time (motion) reversal.

  17. Fluid transportation mechanisms by a coupled system of elastic membranes and magnetic fluids

    International Nuclear Information System (INIS)

    Ido, Y.; Tanaka, K.; Sugiura, Y.

    2002-01-01

    The basic properties of the fluid transportation mechanism that is produced by the coupled waves propagating along a thin elastic membrane covering a magnetic fluid layer in a shallow and long rectangular vessel are investigated. It is shown that the progressive magnetic field induced by the rectangular pulses generates sinusoidal vibration of the displacement of elastic membrane and makes the system work more efficiently than the magnetic field induced by the pulse-width-modulation method

  18. Ultra high field magnetic resonance imaging

    International Nuclear Information System (INIS)

    Lethimonnier, F.; Vedrine, P.

    2007-01-01

    Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research on human subjects. The level of the magnetic field and the scale required will make this joint French-German project to build the magnet a breakthrough in the international arena. (authors)

  19. State of the art magnetic resonance imaging

    International Nuclear Information System (INIS)

    Weissman, J.D.

    1987-01-01

    In less than a decade Magnetic Resonance Imaging (MRI) has evolved from a laboratory demonstration to a safe and effective technique for clinical diagnosis. This evolutionary process continues. At this time 2-D and 3-D imaging of the head and body is firmly established in clinical use. Surface coil imaging, two-component chemical shift imaging, in-vivo spectroscopy and flow imaging are currently in various stages of development. The present state of the art of MRI is a function of an array of technologies: magnet, Rf coil, Rf pulse amplifier, gradient coil and driver, pulse programmer, A/D converter, computer system architecture, array processors and mass storage (both magnetic and optical). The overall product design is the result of a complex process which balances the advantages and disadvantages of each component for optimal system performance and flexibility. The author discusses the organization of a state-of-the-art MRI system. Several examples of the kinds of system interactions affecting design choices are given. (Auth.)

  20. Spatial localization in nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Keevil, Stephen F

    2006-01-01

    The ability to select a discrete region within the body for signal acquisition is a fundamental requirement of in vivo NMR spectroscopy. Ideally, it should be possible to tailor the selected volume to coincide exactly with the lesion or tissue of interest, without loss of signal from within this volume or contamination with extraneous signals. Many techniques have been developed over the past 25 years employing a combination of RF coil properties, static magnetic field gradients and pulse sequence design in an attempt to meet these goals. This review presents a comprehensive survey of these techniques, their various advantages and disadvantages, and implications for clinical applications. Particular emphasis is placed on the reliability of the techniques in terms of signal loss, contamination and the effect of nuclear relaxation and J-coupling. The survey includes techniques based on RF coil and pulse design alone, those using static magnetic field gradients, and magnetic resonance spectroscopic imaging. Although there is an emphasis on techniques currently in widespread use (PRESS, STEAM, ISIS and MRSI), the review also includes earlier techniques, in order to provide historical context, and techniques that are promising for future use in clinical and biomedical applications. (topical review)