WorldWideScience

Sample records for magnetic induction logging

  1. Induction logging device

    Science.gov (United States)

    Koelle, A.R.; Landt, J.A.

    An instrument is disclosed for mapping vertical conductive fractures in a resistive bedrock, magnetically inducing eddy currents by a pair of vertically oriented, mutually perpendicular, coplanar coils. The eddy currents drive magnetic fields which are picked up by a second, similar pair of coils.

  2. Circular induction accelerator for borehole logging

    International Nuclear Information System (INIS)

    Chen, F.K.; Bertozzi, W.; Corris, G.W.; Diamond, W.; Doucet, J.A.; Schweitzer, J.S.

    1992-01-01

    This patent describes a downhole logging sonde adapted to be moved through a borehole, a source of gamma rays in the sonde for irradiating earth formations traversed by the borehole, one or more gamma ray detectors for detecting gamma rays scattered back to the sonde from the irradiated earth formations, and means for transmitting signals representative of the detected gamma rays to the earth's surface for processing. This patent describes improvement in the gamma ray source comprises a magnetic induction particle accelerator, including: a magnetic circuit having a field magnet, generally circular opposed pole pieces, and a core magnet metal ions from the group consisting of Mn, Zn and Ni; an excitation circuit including a field coil surrounding the field magnet and the core magnet and a core coil surrounding the central axially leg of the core magnet; an annular acceleration chamber interposed between the pole pieces; means for applying time-varying acceleration voltage pulses across the primary excitation circuit; means for injecting charged particles into orbit within the acceleration chamber; means for compressing the particle orbits to trap particles within generally circular orbits within the acceleration chamber; means for generating a particle accelerating magnetic flux in the magnetic circuit; and means for ejecting charged particles from the generally circular orbits and into contact with a target to produce gamma ray photons

  3. The nuclear magnetic resonance well logging

    International Nuclear Information System (INIS)

    Zhang Yumin; Shen Huitang

    2003-01-01

    In this paper, the characteristic of the nuclear magnetic resonance logging is described at first. Then its development and its principle is presented. Compared with the nuclear magnetic resonance spectrometer, the magnet techniques is the first question that we must solve in the manufacture of the NMR well logging

  4. Intrinsic magnetic torque at low magnetic induction

    International Nuclear Information System (INIS)

    Doria, M.M.; Oliveira, I.G. de.

    1993-01-01

    Using anisotropic London theory the intrinsic magnetic torque for extreme type II uniaxial superconductors for any value of the magnetic induction is obtained. It is considered the vortex lines straight and take into account the contribution of the supercurrents flowing inside the vortex core within the London theory. It is shown that the interline and intra line free energies give opposite torque contributions, the first drives the magnetic induction parallel to the superconductor's axis of symmetry and the second orthogonal to it. At high magnetic induction torque expression obtained generalizes V. Kogan's formula since it has no free parameters other than the anisotropy γ = m 1 /m 3 and the Ginzburg-Landau parameter κ. At low magnetic induction it is proposed a way to observe vortex chains effects in the total torque based on the fact that London theory is linear and the energy to make a single vortex line in space is independent of the magnetic induction. (author)

  5. Comparison between moving and stationary transmitter systems in induction logging

    Science.gov (United States)

    Poddar, M.; Caleb Dhanasekaran, P.; Prabhakar Rao, K.

    1985-09-01

    In a general treatment of the theory of induction logging, an exact integral representation has been obtained for the mutual impedance between a vertical dipole transmitter and a coaxial dipole receiver in a three layered earth. Based on this representation, a computer model has been devised using the traditional Slingram system of induction logging and the comparatively new Turam system, ignoring borehole effects. The model results indicate that due to its much larger response, the Turam system is in general preferable to the Slingram in mineral and groundwater investigations where formation conductivity much less than 1 S/m is generally encountered. However, if the surrounding media are conductive (more than 0.1 S/m), the Turam system suffers from large amplitude attenuation and phase rotation of the primary field caused by the conductive surrounding, and is less useful than the Slingram system which does not so suffer, unless the target bed is shallow. Because it is a more complex function of system parameters than the corresponding Slingram log, a Turam log can be conveniently interpreted only by the modern inverse method using a fast algorithm for the forward solution and a high speed digital computer.

  6. Comparative analysis of nuclear magnetic resonance well logging and nuclear magnetic resonance mud logging

    International Nuclear Information System (INIS)

    Yuan Zugui

    2008-01-01

    The hydrogen atoms in oil and water are able to resonate and generate signals in the magnetic field, which is used by the NMR (nuclear magnetic resonance) technology in petroleum engineering to research and evaluate rock characteristics. NMR well logging was used to measure the physical property parameters of the strata in well bore, whereas NMR mud logging was used to analyze (while drilling) the physical property parameters of cores, cuttings and sidewall coring samples on surface (drilling site). Based on the comparative analysis of the porosity and permeability parameters obtained by NMR well logging and those from analysis of the cores, cuttings and sidewall coring samples by NMR mud logging in the same depth of 13 wells, these two methods are of certain difference, but their integral tendency is relatively good. (authors)

  7. Selective Induction of Optical Magnetism.

    Science.gov (United States)

    Manna, Uttam; Lee, Jung-Hoon; Deng, Tian-Song; Parker, John; Shepherd, Nolan; Weizmann, Yossi; Scherer, Norbert F

    2017-12-13

    An extension of the Maxwell-Faraday law of electromagnetic induction to optical frequencies requires spatially appropriate materials and optical beams to create resonances and excitations with curl. Here we employ cylindrical vector beams with azimuthal polarization to create electric fields that selectively drive magnetic responses in dielectric core-metal nanoparticle "satellite" nanostructures. These optical frequency magnetic resonances are induced in materials that do not possess spin or orbital angular momentum. Multipole expansion analysis of the scattered fields obtained from electrodynamics simulations show that the excitation with azimuthally polarized beams selectively enhances magnetic vs electric dipole resonances by nearly 100-fold in experiments. Multipolar resonances (e.g., quadrupole and octupole) are enhanced 5-fold by focused azimuthally versus linearly polarized beams. We also selectively excite electric multipolar resonances in the same identical nanostructures with radially polarized light. This work opens new opportunities for spectroscopic investigation and control of "dark modes", Fano resonances, and magnetic modes in nanomaterials and engineered metamaterials.

  8. Forward modelling of multi-component induction logging tools in layered anisotropic dipping formations

    International Nuclear Information System (INIS)

    Gao, Jie; Xu, Chenhao; Xiao, Jiaqi

    2013-01-01

    Multi-component induction logging provides great assistance in the exploration of thinly laminated reservoirs. The 1D parametric inversion following an adaptive borehole correction is the key step in the data processing of multi-component induction logging responses. To make the inversion process reasonably fast, an efficient forward modelling method is necessary. In this paper, a modelling method has been developed to simulate the multi-component induction tools in deviated wells drilled in layered anisotropic formations. With the introduction of generalized reflection coefficients, the analytic expressions of magnetic field in the form of a Sommerfeld integral were derived. The fast numerical computation of the integral has been completed by using the fast Fourier–Hankel transform and fast Hankel transform methods. The latter is so time efficient that it is competent enough for real-time multi-parameter inversion. In this paper, some simulated results have been presented and they are in excellent agreement with the finite difference method code's solution. (paper)

  9. Borehole induction logging for the Dynamic Underground Stripping Project LLNL gasoline spill site

    International Nuclear Information System (INIS)

    Boyd, S.; Newmark, R.; Wilt, M.

    1994-01-01

    Borehole induction logs were acquired for the purpose of characterizing subsurface physical properties and monitoring steam clean up activities at the Lawrence Livermore National Laboratory. This work was part of the Dynamic Underground Stripping Project's demonstrated clean up of a gasoline spin. The site is composed of unconsolidated days, sands and gravels which contain gasoline both above and below the water table. Induction logs were used to characterize lithology, to provide ''ground truth'' resistivity values for electrical resistance tomography (ERT), and to monitor the movement of an underground steam plume used to heat the soil and drive volatile organic compounds (VOCs) to the extraction wells

  10. Magnetic storms and induction hazards

    Science.gov (United States)

    Love, Jeffrey J.; Rigler, E. Joshua; Pulkkinen, Antti; Balch, Christopher

    2014-01-01

    Magnetic storms are potentially hazardous to the activities and technological infrastructure of modern civilization. This reality was dramatically demonstrated during the great magnetic storm of March 1989, when surface geoelectric fields, produced by the interaction of the time-varying geomagnetic field with the Earth's electrically conducting interior, coupled onto the overlying Hydro-Québec electric power grid in Canada. Protective relays were tripped, the grid collapsed, and about 9 million people were temporarily left without electricity [Bolduc, 2002].

  11. Environmental corrections of a dual-induction logging while drilling tool in vertical wells

    Science.gov (United States)

    Kang, Zhengming; Ke, Shizhen; Jiang, Ming; Yin, Chengfang; Li, Anzong; Li, Junjian

    2018-04-01

    With the development of Logging While Drilling (LWD) technology, dual-induction LWD logging is not only widely applied in deviated wells and horizontal wells, but it is used commonly in vertical wells. Accordingly, it is necessary to simulate the response of LWD tools in vertical wells for logging interpretation. In this paper, the investigation characteristics, the effects of the tool structure, skin effect and drilling environment of a dual-induction LWD tool are simulated by the three-dimensional (3D) finite element method (FEM). In order to closely simulate the actual situation, real structure of the tool is taking into account. The results demonstrate that the influence of the background value of the tool structure can be eliminated. The values of deducting the background of a tool structure and analytical solution have a quantitative agreement in homogeneous formations. The effect of measurement frequency could be effectively eliminated by chart of skin effect correction. In addition, the measurement environment, borehole size, mud resistivity, shoulder bed, layer thickness and invasion, have an effect on the true resistivity. To eliminate these effects, borehole correction charts, shoulder bed correction charts and tornado charts are computed based on real tool structure. Based on correction charts, well logging data can be corrected automatically by a suitable interpolation method, which is convenient and fast. Verified with actual logging data in vertical wells, this method could obtain the true resistivity of formation.

  12. Multichannel simultaneous magnetic induction measurement system (MUSIMITOS)

    International Nuclear Information System (INIS)

    Steffen, Matthias; Leonhardt, Steffen; Heimann, Konrad; Bernstein, Nina

    2008-01-01

    Non-contact heart and lung activity monitoring would be a desirable supplement to conventional monitoring techniques. Based on the potential of non-contact magnetic induction measurements, requirements for an adequate monitoring system were estimated. This formed the basis for the development of the presented extendable multichannel simultaneous magnetic induction measurement system (MUSIMITOS). Special focus was given to the dynamic behaviour and simultaneous multichannel measurements, so that the system allows for up to 14 receiver coils working simultaneously at 6 excitation frequencies. Moreover, a real-time software concept for online signal processing visualization in combination with a fast software demodulation is presented. Finally, first steps towards a clinical application are pointed out and technical performance as well as first in vivo measurements are presented. This paper covers some aspects previously presented in Steffen and Leonhardt (2007 Proc. 13th Int. Conf. on Electrical Bioimpedance and the 8th Conf. on Electrical Impedance Tomography, Graz 2007)

  13. Inductive voltage compensation in superconducting magnet systems

    International Nuclear Information System (INIS)

    Yeh, H.T.; Goddard, J.S.; Shen, S.S.

    1979-01-01

    This paper details several techniques of inductive voltage compensation developed for quench detection in superconducting magnet systems with multiple coils and power supplies, with particular application for the Large Coil Test Facility (LCTF). Sources of noise, their magnitudes, and the sensitivity required for normal zone detection to avoid damage to the magnets are discussed. Two passive compensation schemes (second difference and central difference) are introduced and illustrated by parameters of LCTF; these take advantage of coil symmetries and other system characteristics. An active compensation scheme based on current rate input fom pickup coils and utilizing theory on ac loss voltage for calibration was tested, and the experimental setup and test results are discussed

  14. Ammonia synthesis using magnetic induction method (MIM)

    Science.gov (United States)

    Puspitasari, P.; Razak, J. Abd; Yahya, N.

    2012-09-01

    The most challenging issues for ammonia synthesis is to get the high yield. New approach of ammonia synthesis by using Magnetic Induction Method (MIM) and the Helmholtz Coils has been proposed. The ammonia detection was done by using Kjeldahl Method and FTIR. The system was designed by using Autocad software. The magnetic field of MIM was vary from 100mT-200mT and the magnetic field for the Helmholtz coils was 14mT. The FTIR result shows that ammonia has been successfully formed at stretching peaks 1097,1119,1162,1236, 1377, and 1464 cm-1. UV-VIS result shows the ammonia bond at 195nm of wavelength. The ammonia yield was increase to 244.72μmole/g.h by using the MIM and six pairs of Helmholtz coils. Therefore this new method will be a new promising method to achieve the high yield ammonia at ambient condition (at 25δC and 1atm), under the Magnetic Induction Method (MIM).

  15. Fracture mapping in geothermal fields with long-offset induction logging

    Energy Technology Data Exchange (ETDEWEB)

    Wilt, M.; Takasugi, Shinji; Uchida, Toshihiro [and others

    1997-12-31

    The mapping of producing fractures in a geothermal field is an important technical objective in field development. Locating, orienting, and assessing producing fractures can guide drilling programs and optimize the placement of production and injection wells. A long-offset multicomponent borehole induction resistivity tool capable of surviving the high temperatures encountered in geothermal wells has recently been developed in a NEDO project, {open_quotes}Deep-Seated Geothermal Reservoirs,{close_quotes} and tested in a high temperature environment. Several characteristics of this device make it ideal for detecting producing fractures. Whereas commercial induction logging devices have source-receiver separations of 1 m, this device has multiple sensors with separations up to 8 m, allowing for deeper penetration and the ability to straddle fracture-induced washout zones in boreholes. The three-component measurements also make it possible to map the strike and inclination of nearby fractures and other three-dimensional structures. This, in turn, allows for accurate projection of these structures into the space between wells. In this paper, we describe the design of the tool and show results of a performance test carried out in an oil-field steam flood. Data from vertical sensors are compared to conventional logging results and indicate the recent formation of a low-resistivity zone associated with high temperatures due to steam flood breakthrough. Horizontal field data indicate that the high-temperature zone is irregular in the vicinity of the borehole and more pronounced closest to the steam injector.

  16. Effective Induction Heating around Strongly Magnetized Stars

    Science.gov (United States)

    Kislyakova, K. G.; Fossati, L.; Johnstone, C. P.; Noack, L.; Lüftinger, T.; Zaitsev, V. V.; Lammer, H.

    2018-05-01

    Planets that are embedded in the changing magnetic fields of their host stars can experience significant induction heating in their interiors caused by the planet’s orbital motion. For induction heating to be substantial, the planetary orbit has to be inclined with respect to the stellar rotation and dipole axes. Using WX UMa, for which the rotation and magnetic axes are aligned, as an example, we show that for close-in planets on inclined orbits, induction heating can be stronger than the tidal heating occurring inside Jupiter’s satellite Io; namely, it can generate a surface heat flux exceeding 2 W m‑2. An internal heating source of such magnitude can lead to extreme volcanic activity on the planet’s surface, possibly also to internal local magma oceans, and to the formation of a plasma torus around the star aligned with the planetary orbit. A strongly volcanically active planet would eject into space mostly SO2, which would then dissociate into oxygen and sulphur atoms. Young planets would also eject CO2. Oxygen would therefore be the major component of the torus. If the O I column density of the torus exceeds ≈1012 cm‑2, the torus could be revealed by detecting absorption signatures at the position of the strong far-ultraviolet O I triplet at about 1304 Å. We estimate that this condition is satisfied if the O I atoms in the torus escape the system at a velocity smaller than 1–10 km s‑1. These estimates are valid also for a tidally heated planet.

  17. Review of magnetic susceptibility logging and its application to uranium exploration

    International Nuclear Information System (INIS)

    George, D.C.; Scott, J.H.

    1982-01-01

    Borehole measurement of magnetic susceptibility can show anomalies associated with mineralization or alteration. The detection of small anomalies is necessary, so efforts have been made in recent years to improve the sensitivity and the stability of magnetic susceptibility logging tools. Typical tools contain a single coil constructed as a solenoid wound on ferrite rods about 30cm long. The coil is heated to a constant temperature to reduce drift, and careful design is necessary to optimize temperature control and to maximize sensitivity. Measurements of coil resistance and inductance, which indicate conductivity and susceptibility, are made using a Maxwell bridge circuit. Circuit analysis shows that conductivity measurements are difficult and that stringent requirements are placed on phase stability of measurement circuitry. Corrections to the observed log are necessary to account for borehole size. The response of the tool to a thin zones of anomalous susceptibility is double peaked and a set of curves has been developed for interpretation. Calibrations of the tools are made by measuring the tool's response in models of known susceptibility

  18. Determination of reservoir effective porosity using nuclear magnetic logging data

    International Nuclear Information System (INIS)

    Aksel'rod, S.M.; Danevich, V.I.; Sadykov, D.M.

    1979-01-01

    In connection with the development of nuclear magnetic logging (NML) the possibility has occurred to determine the effective porosity coefficient for rocks directly under the conditions of their occurrence. The initial amplitude of a signal of free precession of NML is proportional to the quantity of free fluid in the rock volume, which is determined by the index of free fluid (IFF). On the basis of the laboratory studies it is shown that the relation between IFF and free water content is always linear and doesn't depend on lithological characteristics of rocks, porous dimensions and distribution. Using this relation it's possible to estimate bound water content. While filling the reservoir with weakly mineralized water the IFF value coincides numerically with the effective porosity coefficient. Otherwise the content of hydrogen nuclei in a volume unit is much less; while calculating the effective porosity coefficient this fact is recorded by the index of the amplitude decrease which depends on temperature and increases with its growth (for oils). In strata containing intercalations of reservoirs and non-reservoirs the averaged according to stratum IFF value determines the mean-weighted values of effective porosity

  19. Measurement of the D0 WAMUS magnet inductance

    International Nuclear Information System (INIS)

    Kristalinski, A.; Hance, R.; Jaskierny, W.

    1994-12-01

    Historically, the term inductance, as it relates to magnets, has been relatively obscure at Fermilab. Confusion resulted from the typical engineering approach to the matter, whereby distinction may not have been made between analytical and beam line magnets; and distribution transformers. The latter always have a laminated core to reduce eddy currents which makes their inductance in a transitional state very close to that in a steady state. This is true only if the core material is not in saturation, which is once again the case for transformers; but not for magnets, especially the analytical ones. Based on the traditional ''transformer'' thinking, an incorrect method to measure magnet inductance was initially employed. The characteristics of a tank circuit including the magnet under test were observed. Then based on the resonant frequency and quality factor, the inductance was calculated. This method represents a very valuable tool for magnet testing where you can compare newly built magnets to a reference magnet and see if there is any difference. Although electrically correct, this method unfortunately does not reveal any valuable information which could be used to anticipate the magnet behavior under the normal working conditions. Another method of measuring inductance, based on a freewheeling discharge of the magnet, is also widely used in the Lab. To measure the inductance, a magnet is powered from a small power supply for up to 100 A to 200 A, then the power is turned off and the current decay in the magnet is recorded. Based on the dc resistance measurements and the magnet current decay data, one can determine the magnet inductance. In order to do so, the inductance is assumed to be constant and current decay is assumed to be exponential. To find out how well the effective inductance represents the real process taking place in the magnet was one of the purposes of the experiment

  20. Observation of Magnetic Induction Distribution by Scanning Interference Electron Microscopy

    Science.gov (United States)

    Takahashi, Yoshio; Yajima, Yusuke; Ichikawa, Masakazu; Kuroda, Katsuhiro

    1994-09-01

    A scanning interference electron microscope (SIEM) capable of observing magnetic induction distribution with high sensitivity and spatial resolution has been developed. The SIEM uses a pair of fine coherent scanning probes and detects their relative phase change by magnetic induction, giving raster images of microscopic magnetic distributions. Its performance has been demonstrated by observing magnetic induction distributed near the edge of a recorded magnetic storage medium. Obtained images are compared with corresponding images taken in the scanning Lorentz electron microscope mode using the same microscope, and the differences between them are discussed.

  1. Distributed generation induction and permanent magnet generators

    CERN Document Server

    Lai, L

    2007-01-01

    Distributed power generation is a technology that could help to enable efficient, renewable energy production both in the developed and developing world. It includes all use of small electric power generators, whether located on the utility system, at the site of a utility customer, or at an isolated site not connected to the power grid. Induction generators (IGs) are the cheapest and most commonly used technology, compatible with renewable energy resources. Permanent magnet (PM) generators have traditionally been avoided due to high fabrication costs; however, compared with IGs they are more reliable and productive. Distributed Generation thoroughly examines the principles, possibilities and limitations of creating energy with both IGs and PM generators. It takes an electrical engineering approach in the analysis and testing of these generators, and includes diagrams and extensive case study examples o better demonstrate how the integration of energy sources can be accomplished. The book also provides the ...

  2. CALCULATION OF INDUCTANCE OF THE INTERIOR PERMANENT MAGNET SYNCHRONOUS MOTOR

    Directory of Open Access Journals (Sweden)

    Phyong Le Ngo

    2017-01-01

    Full Text Available Interior permanent magnet synchronous motor (IPMSM refers to salient-pole synchronous motors, characterized by inequality of inductances of longitudinal (d and transverse (q axes. Electromagnetic torque of IPMSM consists of two components: active torque and reactive torque; the latter depends on inductances of d and q axes. An analytical method to calculate own inductances and mutual inductances of a three-phase IPMSM is presented. Distributed windings of the stator are substituted by equivalent sine distributed windings. An interior permanent magnets rotor is substituted by an equivalent salient-pole rotor. Sections of a magnetic circuit comprising interior permanent magnets, air barriers and steel bridges are substituted by equivalent air-gap. The expressions of the magnetic induction created by current of the stator windings at each point of the air gap as well as of magnetic flux linkage of the stator windings have been obtained. The equations of the self-inductances of phases A, B, C, and of inductance of mutual induction are determined from magnetic flux linkage. The inductance of the d and q axes have been obtained as a result of transformation of the axes abc–dq. The results obtained with the use of the proposed analytical method and the finite element method are presented in the form of a graph; the calculations that have been obtained by these two methods were compared. 

  3. An induction heating device using planar coil with high amplitude alternating magnetic fields for magnetic hyperthermia.

    Science.gov (United States)

    Wu, Zuhe; Zhuo, Zihang; Cai, Dongyang; Wu, Jian'an; Wang, Jie; Tang, Jintian

    2015-01-01

    Induction heating devices using the induction coil and magnetic nanoparticles (MNPs) are the way that the magnetic hyperthermia is heading. To facilitate the induction heating of in vivo magnetic nanoparticles in hyperthermia experiments on large animals. An induction heating device using a planar coil was designed with a magnetic field frequency of 328 kHz. The coil's magnetic field distribution and the device's induction heating performance on different concentrations of magnetic nanoparticles were measured. The alternating magnetic field produced in the axis position 165 mm away from the coil center is 40 Gs in amplitude; magnetic nanoparticles with a concentration higher than 80 mg. mL-1 can be heated up rapidly. Our results demonstrate that the device can be applied not only to in vitro and in small animal experiments of magnetic hyperthermia using MNPs, but also in large animal experiments.

  4. MAGNETIC INDUCTION DISTRIBUTION IN A LINEAR SYNCHRONUS MOTOR WITH MAGNETIC SUSPENSION

    Directory of Open Access Journals (Sweden)

    D.I. Parkhomenko

    2013-02-01

    Full Text Available Results of computer simulation and experimental investigations of magnetic induction distribution in a coaxial linear synchronous motor with magnetic suspension are presented. The magnetic induction distribution has been studied both in the motor air gap and on the runner surface.

  5. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Jun, Zhang; Ouyang, Ziwei; Duffy, M. C.

    2013-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...

  6. Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction

    OpenAIRE

    Xia, Rongmin; Li, Xu; He, Bin

    2007-01-01

    Magnetoacoustic tomography with magnetic induction (MAT-MI) is a recently introduced method for imaging tissue electrical impedance properties by integrating magnetic induction and ultrasound measurements. In the present study, we have developed a focused cylindrical scanning mode MAT-MI system and the corresponding reconstruction algorithms. Using this system, we demonstrated 3-dimensional MAT-MI imaging in a physical phantom, with cylindrical scanning combined with ultrasound focusing, and ...

  7. Apparent resistivity for transient electromagnetic induction logging and its correction in radial layer identification

    Science.gov (United States)

    Meng, Qingxin; Hu, Xiangyun; Pan, Heping; Xi, Yufei

    2018-04-01

    We propose an algorithm for calculating all-time apparent resistivity from transient electromagnetic induction logging. The algorithm is based on the whole-space transient electric field expression of the uniform model and Halley's optimisation. In trial calculations for uniform models, the all-time algorithm is shown to have high accuracy. We use the finite-difference time-domain method to simulate the transient electromagnetic field in radial two-layer models without wall rock and convert the simulation results to apparent resistivity using the all-time algorithm. The time-varying apparent resistivity reflects the radially layered geoelectrical structure of the models and the apparent resistivity of the earliest time channel follows the true resistivity of the inner layer; however, the apparent resistivity at larger times reflects the comprehensive electrical characteristics of the inner and outer layers. To accurately identify the outer layer resistivity based on the series relationship model of the layered resistance, the apparent resistivity and diffusion depth of the different time channels are approximately replaced by related model parameters; that is, we propose an apparent resistivity correction algorithm. By correcting the time-varying apparent resistivity of radial two-layer models, we show that the correction results reflect the radially layered electrical structure and the corrected resistivities of the larger time channels follow the outer layer resistivity. The transient electromagnetic fields of radially layered models with wall rock are simulated to obtain the 2D time-varying profiles of the apparent resistivity and corrections. The results suggest that the time-varying apparent resistivity and correction results reflect the vertical and radial geoelectrical structures. For models with small wall-rock effect, the correction removes the effect of the low-resistance inner layer on the apparent resistivity of the larger time channels.

  8. Magnetic Viscosity for Cyclostratigraphic Logging of Argillaceous Sediment

    Directory of Open Access Journals (Sweden)

    Alain Tabbagh

    2009-09-01

    Full Text Available Magnetic susceptibility (MS is currently used as a directly representative proxy for the study of climatic variations, and for cyclostratigraphic studies. It depends on the concentration of magnetic minerals in the rocks, but does not allow identifying the magnetic minerals. In the case of argillaceous sediments, the paramagnetism of clay particles often plays a major role in determining the magnitude of their magnetic susceptibility, while the presence of ferrimagnetic iron oxides or sulfides cannot be assessedusing susceptibility measurements alone. Among the different methods that can be used to detect ferrimagnetic particles magnetic viscosity (MV characterizing the delay corresponding to the acquisition or loss of induced magnetization, has the same advantages as MS. Itsmeasurement is direct, rapid and has been proven to be very efficient in detecting the presence of secondary ferrimagnetic minerals in soils. A MV measurement technique was tested on cores taken from a borehole, in Callovian-Oxfordian formations in the eastern Paris Basin (France (Fig. 1. Although the MV values are very small, they have cyclic variations of which strongest values are found at the base of the Lower Oxfordian. These values, when correlated to MS,Gamma Ray (GR and a sequential interpretation of a borehole drilled close-by are found to be associated with the maximum clay fraction in the core samples, a MS maximum, and a major transgression event. Consequently, a significant increase in ferrimagnetic minerals can be associated with this event.

  9. Characteristics of The Magnet Wheel As A Magnetic Levitation Device of Induction Type

    OpenAIRE

    藤井, 信男; 小川, 幸吉; 松本, 敏雄; Nobuo, FUJII; Kokichi, OGAWA; Toshio, MATSUMOTO; 九州大学; 大分大学; 安川電機; Kyushu University; Oita University; Yaskawa Electric Co., Ltd.

    1996-01-01

    A new type of magnetic wheel called the "magnet wheel" has been proposed. The magnet wheel has both magnetic levitation and linear drive functions combined into one. In the magnet wheel, the permanent magnets are rotated over the conducting plate so that an induction type of repulsive lift force is obtained. To produce thrust from the drag torque which is simultaneously induced with the lift force, the "tilt type" and "partial overlap type" magnet wheels have been proposed. Poor power factor ...

  10. Magnetic field, inductance of circular coil and solenoids

    International Nuclear Information System (INIS)

    Ramirez Hoyos, P.; Barbero Garcia, A.J.; Mafe Matoses, S.

    1995-01-01

    The self-inductance of a current-carrying circular coil and the mutual inductances of the Helmholtz coils and coil-sole-noid systems have been measured and calculated theoretically. The experiments and the required equipment are suited to an undergraduate laboratory. The theoretical calculation involve the use of simple numerical integration methods for evaluating the magnetic field of the circular coil and the inductances. The calculated values agree with the measurements within the experimental error. The material presented can be proposed to the students as a laboratory project. (Author) 7 refs

  11. Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction

    Science.gov (United States)

    Xia, Rongmin; Li, Xu; He, Bin

    2007-08-01

    Magnetoacoustic tomography with magnetic induction (MAT-MI) is a recently introduced method for imaging tissue electrical impedance properties by integrating magnetic induction and ultrasound measurements. In the present study, the authors have developed a focused cylindrical scanning mode MAT-MI system and the corresponding reconstruction algorithms. Using this system, they demonstrated a three-dimensional MAT-MI imaging approach in a physical phantom, with cylindrical scanning combined with ultrasound focusing, and the ability of MAT-MI in imaging electrical conductivity properties of biological tissue.

  12. EM Induction Experiment to Determine the Moment of a Magnet

    Science.gov (United States)

    Najiya Maryam, K. M.

    2014-01-01

    If we drop a magnet through a coil, an emf is induced in the coil according to Faraday's law of electromagnetic induction. Here, such an experiment is done using expEYES kit. The plot of emf versus time has a specific shape with two peaks. A theoretical analysis of this graph is discussed here for both short and long cylindrical magnets.…

  13. Development of Induction Logging Technology for Non-Stationary Conditions While Drilling Subhorozontal Sections of Oil and Gas Wells

    Directory of Open Access Journals (Sweden)

    V. K. Teplukhin

    2017-06-01

    Full Text Available The article presents the results of development of the induction logging module designed for resistivity measurements while drilling horizontal and directional wells for oil and gas. Materials of the tool testing during the drilling of wells in the oil field in the Republic of Bashkortostan are shown. We introduce the comparative analysis of resistivity data obtained after completion of the drilling, and the results obtained with developed complex as part of the LWD telemetry system TARGET during the drilling. The technical characteristics of complex MIR are presented.

  14. Force analysis of linear induction motor for magnetic levitation system

    NARCIS (Netherlands)

    Kuijpers, A.A.; Nemlioglu, C.; Sahin, F.; Verdel, A.J.D.; Compter, J.C.; Lomonova, E.

    2010-01-01

    This paper presents the analyses of thrust and normal forces of linear induction motor (LIM) segments which are implemented in a rotating ring system. To obtain magnetic levitation in a cost effective and sustainable way, decoupled control of thrust and normal forces is required. This study includes

  15. Simulation of magnetic induction distribution in a coaxial linear motor with axial and radial direction of permanent magnets magnetization

    Directory of Open Access Journals (Sweden)

    G.M. Golenkov

    2014-03-01

    Full Text Available The paper presents results of computer simulation and experimental study of magnetic induction distribution in a coaxial linear motor air gap throughout the length of the runner active part at different heights of the air gap between the runner and the inductor magnetic core for motors with axial and radial direction of the permanent magnets magnetization.

  16. Development of multi-frequency array induction logging (MAIL) tool. Part 4; Multi shuhasu array gata induction kenso (MAIL) tool no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T.; Otsuka, K.; Takasugi, S. [GERD Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan); Uchida, T. [New Energy and Industrial Technology Development Organization, Tokyo, (Japan)

    1997-05-27

    NEDO is now carrying out `the deep-seated geothermal resource survey` with the aim of surveying deep geothermal resource lying 3,000m below sea level. `The development of resistivity use investigation technology` being carried out as element technology for this survey conducts well surveys and earth surface-well surveys using the drilled deep wells. By analyzing these surveys together with electromagnetic method surveys including the MT method carried out on the earth surface, the survey was aimed at grasping in high resolution resistivity structures from the shallow underground to the deep underground. The multi-frequency array induction logging being researched as the well survey is a method to grasp resistivity structures within a radius of several meters of the well using the electromagnetic logging method. The paper reported the field test conducted this time using the improved tool. A comparison of the data obtained in the test with the results of the normal logging showed consistency, and therefore, it showed that the tool itself fully grasped responses from strata. 3 refs., 5 figs., 1 tab.

  17. Streamlined approach to mapping the magnetic induction of skyrmionic materials

    International Nuclear Information System (INIS)

    Chess, Jordan J.; Montoya, Sergio A.; Harvey, Tyler R.; Ophus, Colin; Couture, Simon; Lomakin, Vitaliy; Fullerton, Eric E.; McMorran, Benjamin J.

    2017-01-01

    Highlights: • A method to reconstruction the phase of electrons after pasting though a sample that requires a single defocused image is presented. • Restrictions as to when it is appropriate to apply this method are described. • The relative error associated with this method is compared to conventional transport of intensity equation analysis. - Abstract: Recently, Lorentz transmission electron microscopy (LTEM) has helped researchers advance the emerging field of magnetic skyrmions. These magnetic quasi-particles, composed of topologically non-trivial magnetization textures, have a large potential for application as information carriers in low-power memory and logic devices. LTEM is one of a very few techniques for direct, real-space imaging of magnetic features at the nanoscale. For Fresnel-contrast LTEM, the transport of intensity equation (TIE) is the tool of choice for quantitative reconstruction of the local magnetic induction through the sample thickness. Typically, this analysis requires collection of at least three images. Here, we show that for uniform, thin, magnetic films, which includes many skyrmionic samples, the magnetic induction can be quantitatively determined from a single defocused image using a simplified TIE approach.

  18. Iterative reconstruction of magnetic induction using Lorentz transmission electron tomography

    International Nuclear Information System (INIS)

    Phatak, C.; Gürsoy, D.

    2015-01-01

    Intense ongoing research on complex nanomagnetic structures requires a fundamental understanding of the 3D magnetization and the stray fields around the nano-objects. 3D visualization of such fields offers the best way to achieve this. Lorentz transmission electron microscopy provides a suitable combination of high resolution and ability to quantitatively visualize the magnetization vectors using phase retrieval methods. In this paper, we present a formalism to represent the magnetic phase shift of electrons as a Radon transform of the magnetic induction of the sample. Using this formalism, we then present the application of common tomographic methods particularly the iterative methods, to reconstruct the 3D components of the vector field. We present an analysis of the effect of missing wedge and the limited angular sampling as well as reconstruction of complex 3D magnetization in a nanowire using simulations. - Highlights: • We present a formalism to represent electron-optical magnetic phase shift as a Radon transform of the 3D magnetic induction of the nano-object. • We have analyzed four different tomographic reconstruction methods for vectorial data reconstruction. • Reconstruction methods were tested for varying experimental limitations such as limited tilt range and limited angular sampling. • The analysis showed that Gridrec and SIRT methods performed better with lower errors than other reconstruction methods

  19. Streamlined approach to mapping the magnetic induction of skyrmionic materials

    Energy Technology Data Exchange (ETDEWEB)

    Chess, Jordan J., E-mail: jchess@uoregon.edu [Department of Physics, University of Oregon, Eugene, OR 97403 (United States); Montoya, Sergio A. [Center for Memory and Recording Research, University of California, San Diego, CA 92093 (United States); Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA 92093 (United States); Harvey, Tyler R. [Department of Physics, University of Oregon, Eugene, OR 97403 (United States); Ophus, Colin [National Center for Electron Microscopy, Molecular Foundry, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Couture, Simon; Lomakin, Vitaliy; Fullerton, Eric E. [Center for Memory and Recording Research, University of California, San Diego, CA 92093 (United States); Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA 92093 (United States); McMorran, Benjamin J. [Department of Physics, University of Oregon, Eugene, OR 97403 (United States)

    2017-06-15

    Highlights: • A method to reconstruction the phase of electrons after pasting though a sample that requires a single defocused image is presented. • Restrictions as to when it is appropriate to apply this method are described. • The relative error associated with this method is compared to conventional transport of intensity equation analysis. - Abstract: Recently, Lorentz transmission electron microscopy (LTEM) has helped researchers advance the emerging field of magnetic skyrmions. These magnetic quasi-particles, composed of topologically non-trivial magnetization textures, have a large potential for application as information carriers in low-power memory and logic devices. LTEM is one of a very few techniques for direct, real-space imaging of magnetic features at the nanoscale. For Fresnel-contrast LTEM, the transport of intensity equation (TIE) is the tool of choice for quantitative reconstruction of the local magnetic induction through the sample thickness. Typically, this analysis requires collection of at least three images. Here, we show that for uniform, thin, magnetic films, which includes many skyrmionic samples, the magnetic induction can be quantitatively determined from a single defocused image using a simplified TIE approach.

  20. Magnetic induction heating of FeCr nanocrystalline alloys

    International Nuclear Information System (INIS)

    Gómez-Polo, C.; Larumbe, S.; Pérez-Landazábal, J.I.; Pastor, J.M.; Olivera, J.; Soto-Armañanzas, J.

    2012-01-01

    In this work the thermal effects of magnetic induction heating in (FeCr) 73.5 Si 13.5 Cu 1 B 9 Nb 3 amorphous and nanocrystalline wires were analyzed. A single piece of wire was immersed in a glass capillary filled with water and subjected to an ac magnetic field (frequency, 320 kHz). The initial temperature rise enabled the determination of the effective Specific Absorption Rate (SAR). Maximum SAR values are achieved for those samples displaying high magnetic susceptibility, where the eddy current losses dominate the induction heating behavior. Moreover, the amorphous sample with Curie temperature around room temperature displays characteristic features of self-regulated hyperthermia. - Highlights: ► Amorphous and nanocrystalline Fe based alloys with tailored Curie temperature of the amorphous phase. ► Induction heating effects under the action of a ac magnetic field. ► Self-regulated characteristics based on the control of the Curie temperature. ► Dominant role of the eddy-current losses in the self-heating phenomena.

  1. Fourier-based magnetic induction tomography for mapping resistivity

    International Nuclear Information System (INIS)

    Puwal, Steffan; Roth, Bradley J.

    2011-01-01

    Magnetic induction tomography is used as an experimental tool for mapping the passive electromagnetic properties of conductors, with the potential for imaging biological tissues. Our numerical approach to solving the inverse problem is to obtain a Fourier expansion of the resistivity and the stream functions of the magnetic fields and eddy current density. Thus, we are able to solve the inverse problem of determining the resistivity from the applied and measured magnetic fields for a two-dimensional conducting plane. When we add noise to the measured magnetic field, we find the fidelity of the measured to the true resistivity is quite robust for increasing levels of noise and increasing distances of the applied and measured field coils from the conducting plane, when properly filtered. We conclude that Fourier methods provide a reliable alternative for solving the inverse problem.

  2. Instrument for the measuring magnetic field characteristics of induction acceleration

    International Nuclear Information System (INIS)

    Novikov, V.M.; Romasheva, P.I.

    1976-01-01

    An instrument for the measuring instantaneous values of variable and pulsed magnetic fields with an amplitide of 0.005-2.0 and duration of 5x10 -6 -2x10 -2 sec is described. Time resolution is not less than 0.5 musec, measuring accuracy is about 1%. Induction coils are used as sensors. A digital voltmeter serves as a secondary recorder

  3. Recent simulation results of the magnetic induction tomography forward problem

    Directory of Open Access Journals (Sweden)

    Stawicki Krzysztof

    2016-06-01

    Full Text Available In this paper we present the results of simulations of the Magnetic Induction Tomography (MIT forward problem. Two complementary calculation techniques have been implemented and coupled, namely: the finite element method (applied in commercial software Comsol Multiphysics and the second, algebraic manipulations on basic relationships of electromagnetism in Matlab. The developed combination saves a lot of time and makes a better use of the available computer resources.

  4. Application of a new Magnetic Resonance Logging While Drilling Tool in Offshore Nigeria

    International Nuclear Information System (INIS)

    Kamal, O.; Adindu, F.; Anselm, O.; Bacon, R.; Butt, P.; Ogbuagu, C.

    2003-01-01

    This paper describes results gained during the running of a new NMR logging-while-drilling (LWD) tool that has ben designed to run in any By combining with core and magnetic resonance data, probabilistic mineral analysis (with ECS and NGT) showed that the sands with lowest feldspars have the highest permeability. These sands with large grain sizes were deposited in the high-energy upper shore-face environment

  5. Appraisal of electromagnetic induction effects on magnetic pulsation studies

    Directory of Open Access Journals (Sweden)

    B. R. Arora

    Full Text Available The quantification of wave polarization characteristics of ULF waves from the geomagnetic field variations is done under ‘a priori’ assumption that fields of internal induced currents are in-phase with the external inducing fields. Such approximation is invalidated in the regions marked by large lateral conductivity variations that perturb the flow pattern of induced currents. The amplitude and phase changes that these perturbations produce, in the resultant fields at the Earth’s surface, make determination of polarization and phase of the oscillating external signals problematic. In this paper, with the help of a classical Pc5 magnetic pulsation event of 24 March 1991, recorded by dense network of magnetometers in the equatorial belt of Brazil, we document the nature and extent of the possible influence of anomalous induction effects in the wave polarization of ULF waves. The presence of anomalous induction effects at selected sites lead to an over estimation of the equatorial enhancement at pulsation period and also suggest changes in the azimuth of ULF waves as they propagate through the equatorial electrojet. Through numerical calculations, it is shown that anomalous horizontal fields, that result from induction in the lateral conductivity distribution in the study region, vary in magnitude and phase with the polarization of external source field. Essentially, the induction response is also a function of the period of external inducing source field. It is further shown that when anomalous induction fields corresponding to the magnitude and polarization of the 24 March 1991 pulsation event are eliminated from observed fields, corrected amplitude in the X and Y horizontal components allows for true characterisation of ULF wave parameters.

    Key words. Geomagnetism and paleomagnetism (geomagnetic induction – Ionosphere (equatorial ionosphere – Magnetospheric physics (magnetosphere-ionosphere interactions

  6. Effects of a primordial magnetic field with log-normal distribution on the cosmic microwave background

    International Nuclear Information System (INIS)

    Yamazaki, Dai G.; Ichiki, Kiyotomo; Takahashi, Keitaro

    2011-01-01

    We study the effect of primordial magnetic fields (PMFs) on the anisotropies of the cosmic microwave background (CMB). We assume the spectrum of PMFs is described by log-normal distribution which has a characteristic scale, rather than power-law spectrum. This scale is expected to reflect the generation mechanisms and our analysis is complementary to previous studies with power-law spectrum. We calculate power spectra of energy density and Lorentz force of the log-normal PMFs, and then calculate CMB temperature and polarization angular power spectra from scalar, vector, and tensor modes of perturbations generated from such PMFs. By comparing these spectra with WMAP7, QUaD, CBI, Boomerang, and ACBAR data sets, we find that the current CMB data set places the strongest constraint at k≅10 -2.5 Mpc -1 with the upper limit B < or approx. 3 nG.

  7. Energy transfer from a superconducting magnet to an inductive load

    International Nuclear Information System (INIS)

    Onishi, Toshitada; Miura, Akinori.

    1977-01-01

    Experiments on energy transfer between two superconducting magnets have been carried out using an inductive energy transfer system similar to the flying capacitor system developed at the Karlsruhe Institute. In the present system the capacitor is grounded and diodes are used instead of thyristors, and a fraction of stored energy is transferred to the capacitor only when the relay connected in parallel to the magnet is switched off. The capacitor is expected to have no constraint in size, while in the flying capacitor system the capacitor is required to exceed a threshold size. Consequently it is possible to shorten the transfer time to some extent in comparison with the one in the flying capacitor system. Transfer experiments have been carried out using a storage magnet with inductance of 1.2H and a load of 0.41H. The capacitance is 200μF. It is possible to transfer 80.1% of the stored energy of 221 J into the load in less than about 0.35 seconds. (auth.)

  8. Problems of the processing of nuclear magnetic logging signals (identification of fluid-containing strata from a number of measurements)

    International Nuclear Information System (INIS)

    Aliev, T.M.; Orlov, G.L.; Lof, V.M.; Mityushin, E.M.; Ragimova, E.K.

    1978-01-01

    Problems of the processing of nuclear magnetic logging signals to identification of fluid-containing strata from a number of measurements. Problems of application statistical decision theory to discovery of fluid-containing beds from a number of measurements are considered. Using the technique possibilities of nuclear magnetic logging method the necessary volume of samples is motivated, the rational algorithm for processing of sequential measurements is obtained

  9. Downhole logs of natural gamma radiation and magnetic susceptibility and their use in interpreting lithostratigraphy in AND-1B, Antarctica

    Science.gov (United States)

    Williams, T.; Morin, R. H.; Jarrard, R. D.; Jackolski, C. L.; Henrys, S. A.; Niessen, F.; Magens, D.; Kuhn, G.; Monien, D.; Powell, R. D.

    2010-12-01

    The ANDRILL McMurdo Ice Shelf (MIS) project drilled 1285 metres of sediment representing the last 14 million years of glacial history. Downhole geophysical logs were acquired to a depth of 1018 metres, and are complementary to data acquired from the core itself. We describe here the natural gamma radiation (NGR) and magnetic susceptibility logs, and their application to understanding lithological and paleoenvironmental change at ANDRILL McMurdo Ice Shelf Hole AND-1B. Natural gamma radiation logs cover the whole interval from the sea floor to 1018 metres, and magnetic susceptibility and other logs covered the open-hole intervals between 692-1018 and 237-342 metres. NGR logs were stacked and corrected for signal attenuation through the drill pipe, and magnetic susceptibility logs were corrected for drift. In the upper part of AND-1B, clear alternations between low and high NGR values distinguish between diatomite (lacking minerals containing naturally radioactive K, U, and Th) and diamict (containing K-bearing clays, K-feldspar, and heavy minerals). In the lower open-hole logged section, NGR and magnetic susceptibility can also distinguish claystones (rich in K-bearing clay minerals, relatively low in magnetite) and diamicts (relatively high in magnetite), while sandstones generally have high resistivity log values at AND-1B. On the basis of these three downhole logs, three sets of facies can be predicted correctly for 74% of the 692-1018m interval. The logs were then used to predict facies for the 7% of this interval that was unrecovered by coring. Similarly, the NGR log provides the best information on the lithology of the poorly recovered top 25m of AND-1B. Given the understanding of the physical property characteristics of different facies, it is also possible to identify subtle changes in lithology from the physical properties, and help refine parts of the lithostratigraphy (for example, the varying terrigenous content of diatomites).

  10. Scientific Drilling of Impact Craters - Well Logging and Core Analyses Using Magnetic Methods (Invited)

    Science.gov (United States)

    Fucugauchi, J. U.; Perez-Cruz, L. L.; Velasco-Villarreal, M.

    2013-12-01

    Drilling projects of impact structures provide data on the structure and stratigraphy of target, impact and post-impact lithologies, providing insight on the impact dynamics and cratering. Studies have successfully included magnetic well logging and analyses in core and cuttings, directed to characterize the subsurface stratigraphy and structure at depth. There are 170-180 impact craters documented in the terrestrial record, which is a small proportion compared to expectations derived from what is observed on the Moon, Mars and other bodies of the solar system. Knowledge of the internal 3-D deep structure of craters, critical for understanding impacts and crater formation, can best be studied by geophysics and drilling. On Earth, few craters have yet been investigated by drilling. Craters have been drilled as part of industry surveys and/or academic projects, including notably Chicxulub, Sudbury, Ries, Vredefort, Manson and many other craters. As part of the Continental ICDP program, drilling projects have been conducted on the Chicxulub, Bosumtwi, Chesapeake, Ries and El gygytgyn craters. Inclusion of continuous core recovery expanded the range of paleomagnetic and rock magnetic applications, with direct core laboratory measurements, which are part of the tools available in the ocean and continental drilling programs. Drilling studies are here briefly reviewed, with emphasis on the Chicxulub crater formed by an asteroid impact 66 Ma ago at the Cretaceous/Paleogene boundary. Chicxulub crater has no surface expression, covered by a kilometer of Cenozoic sediments, thus making drilling an essential tool. As part of our studies we have drilled eleven wells with continuous core recovery. Magnetic susceptibility logging, magnetostratigraphic, rock magnetic and fabric studies have been carried out and results used for lateral correlation, dating, formation evaluation, azimuthal core orientation and physical property contrasts. Contributions of magnetic studies on impact

  11. Development of multi-frequency array induction logging (MAIL) tool. 3; Multi shuhasu array gata induction kenso tool (MAIL) no kaihatsu (genchi shiken data no ichijigen kaiseki). 3

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T; Osato, K; Takasugi, S [Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan); Uchida, T [New Energy and Industrial Technology Development Organization, Tokyo, (Japan)

    1996-05-01

    A field test was carried out in 1995 on a deep-seated geothermal investigation and reduction well WDR (in Kakkonda, Shizuku-ishi, Iwate Prefecture) by utilizing a multi-frequency array induction logging tool which is under development by NEDO. This paper reports results of analyzing the acquired data. With the WDR wells, an investigation has been conducted to a drilling depth of 330 m. Three frequencies in a range from 3 to 24 kHz provided relatively good data, but data with 42 kHz had poor quality that cannot be utilized for the analysis. Precise device calibration is difficult on data acquired from three array type vertical component magnetometers (the difficulty may be due to a signal line from a transmitter passing on the magnetometer side). Because of this difficulty, analysis using one-dimensional inversion program was performed by using ratio of the amplitude for each frequency and phase difference as input data. The analysis allowed to have derived a result that corresponds to the ground bed structure. 5 refs., 8 figs., 3 tabs.

  12. ''Theta gun,'' a multistage, coaxial, magnetic induction projectile accelerator

    International Nuclear Information System (INIS)

    Burgess, T.J.; Duggin, B.W.; Cowan, M. Jr.

    1985-11-01

    We experimentally and theoretically studied a multistage coaxial magnetic induction projectile accelerator. We call this system a ''theta gun'' to differentiate it from other coaxial accelerator concepts such as the mass driver. We conclude that this system can theoretically attain railgun performance only for large caliber or very high injection velocity and, even then, only for long coil geometry. Our experiments with a three-stage, capactor bank-driven accelerator are described. The experiments are modeled with a 1-1/2 dimensional equivalent circuit-hydrodynamics code which is also described. We derive an expression for the conditions of coaxial accelerator-railgun ''velocity breakeven'' in the absence of ohmic and hydrodynamic effects. This, in conjunction with an expression for the magnetic coupling coefficient, defines a set of geometric relations which the coaxial system must simultaneously satisfy. Conclusions concerning both the existence and configuration of a breakeven coaxial system follow from this requirement. The relative advantages and disadvantages of the coaxial induction projectile accelerator, previously cited in the literature, are critiqued from the viewpoint of our analysis and experimental results. We find that the advantages vis-a-vis the railgun have been overstated. 13 refs., 17 figs

  13. The Inductive Coupling of the Magnets in MICE and its Effect on Quench Protection

    International Nuclear Information System (INIS)

    Green, Michael A.; Witte, Holger

    2005-01-01

    The inductive coupling between various MICE magnet circuits is described. The consequences of this coupling on magnet charging and quenching are discussed. Magnet quench protection is achieved through the use of quench-back. Calculations of the quenching of a magnet due to quench-back resulting from circulating currents induced in the magnet mandrel due to quenching of an adjacent magnet are discussed. This report describes how the MICE magnet channel will react when magnets in that channel are quenched

  14. A quench detection/logging system for the SSCL Magnet Test Laboratory

    International Nuclear Information System (INIS)

    Kim, K.; Coles, M.; Dryer, J.; Lambert, D.

    1993-05-01

    The quench in a magnet describes a process which occurs while the superconductivity state goes to the normal resistive state. The consequence of a quench is the conversion of the stored electromagnetic energy into heat. During this process the initiating point will reach a high temperature, which will char the insulation or melt the conductor and thereby destroy the magnet. To prevent the magnet from being lost, it is standard practice to observe several resistance and/or inductance voltages across the magnet as quench signatures -- detection. When a quench symptom is detected, protection operations are initiated: proper shutdown of the magnet excitation systems and treatment to dilute the heat energy at a spot -- protection. The temperature rise is diluted by firing heaters along the length of the magnet to insure that the dissipated energy is spread. To develop a reliable quench detection system, two distinct approaches have been tried in the past: (i) Understanding of the Noise Mechanism and Sub-system Optimization, and (ii) Escaping from the Known Electromagnetic Noises by Observing Optical Waves or Acoustic Waves. The MTL of SSCL confronts a mass-measurement of about 10,000 production magnets. To meet the testing schedule, the false quench detection rate needs to be further optimized while the true quench detection rate remains secure for the magnet measurement safety. To meet these requirements, we followed an iterative top-down approach. First we defined the signal and noise characteristics of the quench phenomena by using existing software tools to build a rapid prototype system incorporating all proven functionality of the existing system. Then we further optimize the system through iterative upgrading based on our signal and noise character findings

  15. A quench detection/logging system for the SSCL Magnet Test Laboratory

    International Nuclear Information System (INIS)

    Kim, K.; Coles, M.; Dryer, J.; Lambert, D.

    1994-01-01

    The quench in a magnet describes a process which occurs while the superconductivity state goes to the normal resistive state. The consequence of a quench is the conversion of the stored electromagnetic energy into heat. During this process the initiating point will reach a high temperature, which will char the insulation or melt the conductor and thereby destroy the magnet. To prevent the magnet from being lost, it is standard practice to observe several resistance and/or inductance voltages across the magnet as quench signatures - Detection. When a quench symptom is detected, protection operations are initiated: proper shutdown of the magnet excitation systems and treatment to dilute the heat energy at a spot - Protection. The temperature rise is diluted by firing heaters along the length of the magnet to ensure that the dissipated energy is spread. It is interesting that there is not a significant amount of published research on detection. To afford a more reliable quench detection system, two distinct approaches have been tried in the past: (i) Understanding of the Noise Mechanism and Sub-system Optimization, and (ii) Escaping from the Known Electromagnetic Noises by Observing Optical Waves or Acoustic Waves. The MTL of SSCL confronts a mass-measurement of about 10,000 production magnets. To meet the testing schedule, the false quench detection rate needs to be further optimized while the true quench detection rate remains secure for the magnet measurement safety. To meet these requirements, the authors followed an iterative top-down approach. First they defend the signal and noise characteristics of the quench phenomena by using existing software tools to build a rapid prototype system incorporating all proven functionality of the existing system. Then they further optimize the system through iterative upgrading based on their signal and noise character findings

  16. Induction heating of rotating nonmagnetic billet in magnetic field produced by high-parameter permanent magnets

    Directory of Open Access Journals (Sweden)

    Ivo Doležel

    2014-04-01

    Full Text Available An advanced way of induction heating of nonmagnetic billets is discussed and modeled. The billet rotates in a stationary magnetic field produced by unmoving high-parameter permanent magnets fixed on magnetic circuit of an appropriate shape. The mathematical model of the problem consisting of two coupled partial differential equations is solved numerically, in the monolithic formulation. Computations are carried out using our own code Agros2D based on a fully adaptive higher-order finite element method. The most important results are verified experimentally on our own laboratory device.

  17. Induced magnetic-field effects in inductively coupled plasmas

    International Nuclear Information System (INIS)

    Cohen, R.H.; Rognlien, T.D.

    1995-01-01

    In inductive plasma sources, the rapid spatial decay of the electric field arising from the skin effect produces a large radio frequency (RF) magnetic field via Faraday's law. We previously determined that this magnetic field leads to a reduction of the electron density in the skin region, as well as a reduction in the collisionless heating rate. The electron deficit leads to the formation of an electrostatic potential which pulls electrons in to restore quasineutrality. Here we calculate the electron density including both the induced and electrostatic fields. If the wave frequency is not too low, the ions respond only to the averaged fields, and hence the electrostatic field is oscillatory, predominantly at the second harmonic of the applied field. We calculate the potential required to establish a constant electron density, and compare with numerical orbit-code calculations. For times short compared to ion transit times, the quasineutral density is just the initial ion density. For timescales long enough that the ions can relax, the density profile can be found from the solution of fluid equations with an effective (ponderomotive-like) potential added. Although the time-varying electrostatic potential is an extra source of heating, the net effect of the induced magnetic and electrostatic fields through trapping, early turning, and direct heating is a significant reduction in collisionless heating for parameters of interest

  18. Magnetic induction tomography of objects for security applications

    Science.gov (United States)

    Ward, Rob; Joseph, Max; Langley, Abbi; Taylor, Stuart; Watson, Joe C.

    2017-10-01

    A coil array imaging system has been further developed from previous investigations, focusing on designing its application for fast screening of small bags or parcels, with a view to the production of a compact instrument for security applications. In addition to reducing image acquisition times, work was directed toward exploring potential cost effective manufacturing routes. Based on magnetic induction tomography and eddy-current principles, the instrument captured images of conductive targets using a lock-in amplifier, individually multiplexing signals between a primary driver coil and a 20 by 21 imaging array of secondary passive coils constructed using a reproducible multiple tile design. The design was based on additive manufacturing techniques and provided 2 orthogonal imaging planes with an ability to reconstruct images in less than 10 seconds. An assessment of one of the imaging planes is presented. This technique potentially provides a cost effective threat evaluation technique that may compliment conventional radiographic approaches.

  19. Compact, Low-Noise Magnetic Sensor with Fluxgate (DC) and Induction (AC) Modes of Operation

    Science.gov (United States)

    2009-07-01

    induction sensor and the fluxgate magnetometer . ......................................... 2 Figure 3.1 - Impulse response of a 4” long coil (#6...Block diagram of the Year 2, Task 2 fluxgate magnetometer . ................................... 6 Figure 3.3 - FIS-prototype magnetic-field...and demonstrated an innovative dual-mode, fluxgate -induction sensor (FIS) that combines a fluxgate magnetometer and an electromagnetic (EM) induction

  20. Magnetic Logs from the Lopra-1/1A and Vestmanna-1 wells (Faroe Islands)

    DEFF Research Database (Denmark)

    Waagstein, R.; Abrahamsen, N.

    2006-01-01

    basalts poor in magnetite, lapilli-tuffs and tuffs. Thus single measurements of susceptibility are of little use in discriminating between these three types of rock. Susceptibility logs from the Lopra-1/1A  well show that the variation below 3315 m clearly distinguishes between volcaniclastics...... at 2381 m and sidewall cores of basalt from the Lopra-1/1A well have a mean susceptibility of 22.1 ± 3.5 ´ 10-3 SI (σ = 23.6, N = 46), while samples of hyaloclastite (lapilli-tuff and tuff) have a mean susceptibility of 0.85 ´ 10-3 SI (σ = 0.39, N = 17). The mean values of the rock magnetic parameters...

  1. Detection of acute cerebral hemorrhage in rabbits by magnetic induction

    International Nuclear Information System (INIS)

    Sun, J.; Jin, G.; Qin, M.X.; Wan, Z.B.; Wang, J.B.; Wang, C.; Guo, W.Y.; Xu, L.; Ning, X.; Xu, J.; Pu, X.J.; Chen, M.S.; Zhao, H.M.

    2014-01-01

    Acute cerebral hemorrhage (ACH) is an important clinical problem that is often monitored and studied with expensive devices such as computed tomography, magnetic resonance imaging, and positron emission tomography. These devices are not readily available in economically underdeveloped regions of the world, emergency departments, and emergency zones. We have developed a less expensive tool for non-contact monitoring of ACH. The system measures the magnetic induction phase shift (MIPS) between the electromagnetic signals on two coils. ACH was induced in 6 experimental rabbits and edema was induced in 4 control rabbits by stereotactic methods, and their intracranial pressure and heart rate were monitored for 1 h. Signals were continuously monitored for up to 1 h at an exciting frequency of 10.7 MHz. Autologous blood was administered to the experimental group, and saline to the control group (1 to 3 mL) by injection of 1-mL every 5 min. The results showed a significant increase in MIPS as a function of the injection volume, but the heart rate was stable. In the experimental (ACH) group, there was a statistically significant positive correlation of the intracranial pressure and MIPS. The change of MIPS was greater in the ACH group than in the control group. This high-sensitivity system could detect a 1-mL change in blood volume. The MIPS was significantly related to the intracranial pressure. This observation suggests that the method could be valuable for detecting early warning signs in emergency medicine and critical care units

  2. Detection of acute cerebral hemorrhage in rabbits by magnetic induction

    Energy Technology Data Exchange (ETDEWEB)

    Sun, J.; Jin, G.; Qin, M.X. [College of Biomedical Engineering and Medical Imaging, Third Military Medical University, Chongqing, China, College of Biomedical Engineering and Medical Imaging, Third Military Medical University, Chongqing (China); Wan, Z.B. [Experimental Animal Center, Third Military Medical University, Chongqing, China, Experimental Animal Center, Third Military Medical University, Chongqing (China); Wang, J.B.; Wang, C.; Guo, W.Y. [College of Electronic Engineering, Xidian University, Xi' an, China, College of Electronic Engineering, Xidian University, Xi' an (China); Xu, L.; Ning, X.; Xu, J.; Pu, X.J.; Chen, M.S. [College of Biomedical Engineering and Medical Imaging, Third Military Medical University, Chongqing, China, College of Biomedical Engineering and Medical Imaging, Third Military Medical University, Chongqing (China); Zhao, H.M. [Experimental Animal Center, Third Military Medical University, Chongqing, China, Experimental Animal Center, Third Military Medical University, Chongqing (China)

    2014-02-17

    Acute cerebral hemorrhage (ACH) is an important clinical problem that is often monitored and studied with expensive devices such as computed tomography, magnetic resonance imaging, and positron emission tomography. These devices are not readily available in economically underdeveloped regions of the world, emergency departments, and emergency zones. We have developed a less expensive tool for non-contact monitoring of ACH. The system measures the magnetic induction phase shift (MIPS) between the electromagnetic signals on two coils. ACH was induced in 6 experimental rabbits and edema was induced in 4 control rabbits by stereotactic methods, and their intracranial pressure and heart rate were monitored for 1 h. Signals were continuously monitored for up to 1 h at an exciting frequency of 10.7 MHz. Autologous blood was administered to the experimental group, and saline to the control group (1 to 3 mL) by injection of 1-mL every 5 min. The results showed a significant increase in MIPS as a function of the injection volume, but the heart rate was stable. In the experimental (ACH) group, there was a statistically significant positive correlation of the intracranial pressure and MIPS. The change of MIPS was greater in the ACH group than in the control group. This high-sensitivity system could detect a 1-mL change in blood volume. The MIPS was significantly related to the intracranial pressure. This observation suggests that the method could be valuable for detecting early warning signs in emergency medicine and critical care units.

  3. Detection of acute cerebral hemorrhage in rabbits by magnetic induction

    Directory of Open Access Journals (Sweden)

    J. Sun

    2014-02-01

    Full Text Available Acute cerebral hemorrhage (ACH is an important clinical problem that is often monitored and studied with expensive devices such as computed tomography, magnetic resonance imaging, and positron emission tomography. These devices are not readily available in economically underdeveloped regions of the world, emergency departments, and emergency zones. We have developed a less expensive tool for non-contact monitoring of ACH. The system measures the magnetic induction phase shift (MIPS between the electromagnetic signals on two coils. ACH was induced in 6 experimental rabbits and edema was induced in 4 control rabbits by stereotactic methods, and their intracranial pressure and heart rate were monitored for 1 h. Signals were continuously monitored for up to 1 h at an exciting frequency of 10.7 MHz. Autologous blood was administered to the experimental group, and saline to the control group (1 to 3 mL by injection of 1-mL every 5 min. The results showed a significant increase in MIPS as a function of the injection volume, but the heart rate was stable. In the experimental (ACH group, there was a statistically significant positive correlation of the intracranial pressure and MIPS. The change of MIPS was greater in the ACH group than in the control group. This high-sensitivity system could detect a 1-mL change in blood volume. The MIPS was significantly related to the intracranial pressure. This observation suggests that the method could be valuable for detecting early warning signs in emergency medicine and critical care units.

  4. Imaging cerebral haemorrhage with magnetic induction tomography: numerical modelling.

    Science.gov (United States)

    Zolgharni, M; Ledger, P D; Armitage, D W; Holder, D S; Griffiths, H

    2009-06-01

    Magnetic induction tomography (MIT) is a new electromagnetic imaging modality which has the potential to image changes in the electrical conductivity of the brain due to different pathologies. In this study the feasibility of detecting haemorrhagic cerebral stroke with a 16-channel MIT system operating at 10 MHz was investigated. The finite-element method combined with a realistic, multi-layer, head model comprising 12 different tissues, was used for the simulations in the commercial FE package, Comsol Multiphysics. The eddy-current problem was solved and the MIT signals computed for strokes of different volumes occurring at different locations in the brain. The results revealed that a large, peripheral stroke (volume 49 cm(3)) produced phase changes that would be detectable with our currently achievable instrumentation phase noise level (17 m degrees ) in 70 (27%) of the 256 exciter/sensor channel combinations. However, reconstructed images showed that a lower noise level than this, of 1 m degrees , was necessary to obtain good visualization of the strokes. The simulated MIT measurements were compared with those from an independent transmission-line-matrix model in order to give confidence in the results.

  5. Reception pattern influence on magnetoacoustic tomography with magnetic induction

    International Nuclear Information System (INIS)

    Sun Xiao-Dong; Wang Xin; Zhou Yu-Qi; Ma Qing-Yu; Zhang Dong

    2015-01-01

    Based on the acoustic radiation theory of a dipole source, the influence of the transducer reception pattern is studied for magnetoacoustic tomography with magnetic induction (MAT-MI). Numerical studies are conducted to simulate acoustic pressures, waveforms, and reconstructed images with unidirectional, omnidirectional, and strong directional transducers. With the analyses of equivalent and projection sources, the influences of the model dimension and the layer effect are qualitatively analyzed to evaluate the performance of MAT-MI. Three-dimensional simulation studies show that the strong directional transducer with a large radius can reduce the influences of equivalent sources, projection sources, and the layer effect effectively, resulting in enhanced pressure and improved image contrast, which is beneficial for boundary pressure extraction in conductivity reconstruction. The reconstructed conductivity contrast images present the conductivity boundaries as stripes with different contrasts and polarities, representing the values and directions of the conductivity changes of the scanned layer. The favorable results provide solid evidence for transducer selection and suggest potential practical applications of MAT-MI in biomedical imaging. (paper)

  6. Transducer selection and application in magnetoacoustic tomography with magnetic induction

    International Nuclear Information System (INIS)

    Zhou, Yuqi; Wang, Jiawei; Ma, Qingyu; Sun, Xiaodong; Zhang, Dong

    2016-01-01

    As an acoustic receiver, transducer plays a vital role in signal acquisition and image reconstruction for magnetoacoustic tomography with magnetic induction (MAT-MI). In order to optimize signal acquisition, the expressions of acoustic pressure detection and waveform collection are theoretically studied based on the radiation theory of acoustic dipole and the reception pattern of transducer. Pressure distributions are simulated for a cylindrical phantom model using a planar piston transducer with different radii and bandwidths. The proposed theory is also verified by the experimental measurements of acoustic waveform detection for an aluminum foil cylinder. It is proved that acoustic pressure with sharp and clear boundary peaks can be detected by the large-radius transducer with wide bandwidth, reflecting the differential of the induced Lorentz force accurately, which is helpful for precise conductivity reconstruction. To detect acoustic pressure with acceptable pressure amplitude, peak pressure ratio, amplitude ratio, and improved signal to noise ratio, the scanning radius of 5–10 times the radius of the object should be selected to improve the accuracy of image reconstruction. This study provides a theoretical and experimental basis for transducer selection and application in MAT-MI to obtain reconstructed images with improved resolution and definition.

  7. Transducer selection and application in magnetoacoustic tomography with magnetic induction

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Yuqi; Wang, Jiawei; Ma, Qingyu, E-mail: maqingyu@njnu.edu.cn [Key Laboratory of Optoelectronics of Jiangsu Province, School of Physics and Technology, Nanjing Normal University, Nanjing 210023 (China); Sun, Xiaodong [China Key System & Integrated Circuit Co., Ltd., Wuxi 214072 (China); Zhang, Dong [Laboratory of Modern Acoustics of MOE, Institute of Acoustics, Nanjing University, Nanjing 210093 (China)

    2016-03-07

    As an acoustic receiver, transducer plays a vital role in signal acquisition and image reconstruction for magnetoacoustic tomography with magnetic induction (MAT-MI). In order to optimize signal acquisition, the expressions of acoustic pressure detection and waveform collection are theoretically studied based on the radiation theory of acoustic dipole and the reception pattern of transducer. Pressure distributions are simulated for a cylindrical phantom model using a planar piston transducer with different radii and bandwidths. The proposed theory is also verified by the experimental measurements of acoustic waveform detection for an aluminum foil cylinder. It is proved that acoustic pressure with sharp and clear boundary peaks can be detected by the large-radius transducer with wide bandwidth, reflecting the differential of the induced Lorentz force accurately, which is helpful for precise conductivity reconstruction. To detect acoustic pressure with acceptable pressure amplitude, peak pressure ratio, amplitude ratio, and improved signal to noise ratio, the scanning radius of 5–10 times the radius of the object should be selected to improve the accuracy of image reconstruction. This study provides a theoretical and experimental basis for transducer selection and application in MAT-MI to obtain reconstructed images with improved resolution and definition.

  8. Approaches for improving image quality in magnetic induction tomography

    International Nuclear Information System (INIS)

    Maimaitijiang, Y; Roula, M A; Kahlert, J

    2010-01-01

    Magnetic induction tomography (MIT) is a contactless and non-invasive method for imaging the passive electrical properties of objects. Measuring the weak signal produced by eddy currents within biological soft tissues can be challenging in the presence of noise and the large signals resulting from the direct excitation–detection coil coupling. To detect haemorrhagic stroke in the brain, for instance, high measurement accuracy is required to enable images with enough contrast to differentiate between normal and haemorrhaged brain tissues. The reconstructed images are often very sensitive to inevitable measurement noise from the environment, system instabilities and patient-related artefacts such as movement and sweating. We propose methods for mitigating signal noise and improving image reconstruction. We evaluated and compared the use of a range wavelet transforms for signal denoising. Adaptive regularization methods including L-curve, generalized cross validation (GCV) and noise estimation were also compared. We evaluated all these described methods with measurements of in vitro tissues resembling a peripheral haemorrhagic cerebral stroke created by placing a bio-membrane package filled with 10 ml blood in a swine brain of 100 ml. We show that wavelet packet denoising combined with adaptive regularization can improve the quality of reconstructed images

  9. Closed loop control of the induction heating process using miniature magnetic sensors

    Science.gov (United States)

    Bentley, Anthony E.; Kelley, John Bruce; Zutavern, Fred J.

    2003-05-20

    A method and system for providing real-time, closed-loop control of the induction hardening process. A miniature magnetic sensor located near the outer surface of the workpiece measures changes in the surface magnetic field caused by changes in the magnetic properties of the workpiece as it heats up during induction heating (or cools down during quenching). A passive miniature magnetic sensor detects a distinct magnetic spike that appears when the saturation field, B.sub.sat, of the workpiece has been exceeded. This distinct magnetic spike disappears when the workpiece's surface temperature exceeds its Curie temperature, due to the sudden decrease in its magnetic permeability. Alternatively, an active magnetic sensor can measure changes in the resonance response of the monitor coil when the excitation coil is linearly swept over 0-10 MHz, due to changes in the magnetic permeability and electrical resistivity of the workpiece as its temperature increases (or decreases).

  10. Use of miniature magnetic sensors for real-time control of the induction heating process

    Science.gov (United States)

    Bentley, Anthony E.; Kelley, John Bruce; Zutavern, Fred J.

    2002-01-01

    A method of monitoring the process of induction heating a workpiece. A miniature magnetic sensor located near the outer surface of the workpiece measures changes in the surface magnetic field caused by changes in the magnetic properties of the workpiece as it heats up during induction heating (or cools down during quenching). A passive miniature magnetic sensor detects a distinct magnetic spike that appears when the saturation field, B.sub.sat, of the workpiece has been exceeded. This distinct magnetic spike disappears when the workpiece's surface temperature exceeds its Curie temperature, due to the sudden decrease in its magnetic permeability. Alternatively, an active magnetic sensor can also be used to measure changes in the resonance response of the monitor coil when the excitation coil is linearly swept over 0-10 MHz, due to changes in the magnetic permeability and electrical resistivity of the workpiece as its temperature increases (or decreases).

  11. Shear viscosity of the quark-gluon plasma in a weak magnetic field in perturbative QCD: Leading log

    Science.gov (United States)

    Li, Shiyong; Yee, Ho-Ung

    2018-03-01

    We compute the shear viscosity of two-flavor QCD plasma in an external magnetic field in perturbative QCD at leading log order, assuming that the magnetic field is weak or soft: e B ˜g4log (1 /g )T2. We work in the assumption that the magnetic field is homogeneous and static, and the electrodynamics is nondynamical in a formal limit e →0 while e B is kept fixed. We show that the shear viscosity takes a form η =η ¯(B ¯)T3/(g4log (1 /g )) with a dimensionless function η ¯(B ¯) in terms of a dimensionless variable B ¯=(e B )/(g4log (1 /g )T2). The variable B ¯ corresponds to the relative strength of the effect of cyclotron motions compared to the QCD collisions: B ¯˜lmfp/lcyclo. We provide a full numerical result for the scaled shear viscosity η ¯(B ¯).

  12. Effect of inter-tissue inductive coupling on multi-frequency imaging of intracranial hemorrhage by magnetic induction tomography

    Science.gov (United States)

    Xiao, Zhili; Tan, Chao; Dong, Feng

    2017-08-01

    Magnetic induction tomography (MIT) is a promising technique for continuous monitoring of intracranial hemorrhage due to its contactless nature, low cost and capacity to penetrate the high-resistivity skull. The inter-tissue inductive coupling increases with frequency, which may lead to errors in multi-frequency imaging at high frequency. The effect of inter-tissue inductive coupling was investigated to improve the multi-frequency imaging of hemorrhage. An analytical model of inter-tissue inductive coupling based on the equivalent circuit was established. A set of new multi-frequency decomposition equations separating the phase shift of hemorrhage from other brain tissues was derived by employing the coupling information to improve the multi-frequency imaging of intracranial hemorrhage. The decomposition error and imaging error are both decreased after considering the inter-tissue inductive coupling information. The study reveals that the introduction of inter-tissue inductive coupling can reduce the errors of multi-frequency imaging, promoting the development of intracranial hemorrhage monitoring by multi-frequency MIT.

  13. NUMERICAL RESEARCH TECHNIQUES OF MAGNETIC FIELDS GENERATED BY INDUCTION CURRENTS IN A MASSIVE CONDUCTOR

    OpenAIRE

    Tchernykh A. G.

    2015-01-01

    We consider the technology of application of numerical methods in the educational process in physics on the example of a study of the magnetic field induced by induction currents in a cylindrical conductor in a quasi-stationary magnetic field. Here is given the numerical calculation of the real and imaginary parts of the Bessel functions of complex argument. The listing of the program of drawing the graphs of the radial dependence of the amplitude and phase shift of the inductive currents fie...

  14. Magnetic Induction Machines Embedded in Fusion-Bonded Silicon

    National Research Council Canada - National Science Library

    Arnold, David P; Cros, Florent; Zana, Iulica; Allen, Mark G; Das, Sauparna; Lang, Jeffrey H

    2004-01-01

    ...) within etched and fusion-bonded silicon to form the machine structure. The induction machines were characterized in motoring mode using tethered rotors, and exhibited a maximum measured torque...

  15. AIRGAP MAGNETIC INDUCTION DISTRIBUTION IN A COAXIALLY-LINEAR SYNCHRONOUS MOTOR WITH AXIAL AND RADIAL DIRECTION OF THE RUNNER PERMANENT MAGNETS MAGNETIZATION

    Directory of Open Access Journals (Sweden)

    Abbasian Mohsen

    2013-02-01

    Full Text Available Results of theoretical and experimental research on magnetic induction distribution in the air gap of a coaxially-linear synchronous motor with reciprocal motion within the pole pitch and axial and radial direction of the permanent magnets magnetization are presented.

  16. Analysis of the magnetic susceptibility well log in drill hole UE25a-5, Yucca Mountain, Nevada Test Site

    International Nuclear Information System (INIS)

    Hagstrum, J.T.; Daniels, J.J.; Scott, J.H.

    1980-01-01

    Magnetic susceptibility measurements have been shown to be dependent upon the magnetite content of rocks with variations in rock susceptibility arising from changes in the shape, size, composition, and quantity of the contained magnetite grains. The present study was undertaken to determine the factor(s) responsible for the variation in magnetic susceptibility measurements from borehole UE25a-5 on the Nevada Test Site (NTS). The well logs and sample analyses presented in this paper form part of a larger geophysical well-logging project studying the physical properties of welded tuffs at NTS. The ash-flow sheets at NTS appear to be the products of single compositionally zoned magmas that tend, within a cooling unit, to erupt hotter, more mafic, and more crystal-rich with time. These factors, however, have little effect on the degree to which the tuffs become welded. Furthermore, zones of crystallization and alteration are superimposed upon the welded units. X-ray data show poor correspondence between the relative abundance of magnetite in a sample and the borehole magnetic susceptibility measurement associated with it. Curie balance experiments demonstrate no change in the magnetic mineralogy that could account for the susceptibility variation. Thin-section observations corroborate the x-ray data, but indicate a proportional relationship between the borehole susceptibility measurements and the grain-size distribution of magnetite. The association of magnetic susceptibility anomalies with the crystal-rich zones of the welded tuffs will aid in the identification and correlation of the eruptive sequences at NTS

  17. Induction of somaclonal variation and mutations in sugarcane calli for selecting mutants with resistance to red-rot and tolerance to water-logged conditions

    International Nuclear Information System (INIS)

    Shaikh, M.A.Q.; Begum, S.; Samad, M.A.; Shmsuzzaman, K.M.

    1997-01-01

    Immature leaves of cv. 'Isd-16' of sugarcane were cultured on modified MS medium supplemented with 3.0 mg/l 2,4-D for callus induction. The calli were transferred to MS medium supplemented with 5.0 mg/l IAA and 2.0 mg/l KIN for shoot regeneration. The shoots were rooted on MS medium supplemented with 5.0 mg/1NAA and 70 g/l sucrose. The regenerated plants were screened against red-rot disease and water-logged condition in a field. Of the 368 plants inoculated with red-rot pathogen, only one was moderately resistant and two were moderately susceptible. In another set of 500 R 1 plants, six clones were tolerant to water-logged condition. Four week-old callus cultures were irradiated with doses of 2, 3, 4, 5, 6, 7, 8 and 10 Gy gamma-rays. Survival of calli decreased with increase in radiation dose and ranged from 58 to 91%. Regenerated shoots were obtained from all irradiated calli except those treated with 8 and 10 Gy. Shoot regeneration from the irradiated calli ranged from 8 to 50%, and gave 768 R 1 plants. The highest regeneration of plants was obtained from calli treated with 3 Gy. These plants are being grown in a field for screening against red-rot and water-logged conditions. (author). 10 refs, 2 tabs

  18. Induction of somaclonal variation and mutations in sugarcane calli for selecting mutants with resistance to red-rot and tolerance to water-logged conditions

    Energy Technology Data Exchange (ETDEWEB)

    Shaikh, M A.Q.; Begum, S; Samad, M A; Shmsuzzaman, K M [Bangladesh Inst. of Nuclear Agriculture, Mymensingh (Bangladesh)

    1997-07-01

    Immature leaves of cv. `Isd-16` of sugarcane were cultured on modified MS medium supplemented with 3.0 mg/l 2,4-D for callus induction. The calli were transferred to MS medium supplemented with 5.0 mg/l IAA and 2.0 mg/l KIN for shoot regeneration. The shoots were rooted on MS medium supplemented with 5.0 mg/1NAA and 70 g/l sucrose. The regenerated plants were screened against red-rot disease and water-logged condition in a field. Of the 368 plants inoculated with red-rot pathogen, only one was moderately resistant and two were moderately susceptible. In another set of 500 R{sub 1} plants, six clones were tolerant to water-logged condition. Four week-old callus cultures were irradiated with doses of 2, 3, 4, 5, 6, 7, 8 and 10 Gy gamma-rays. Survival of calli decreased with increase in radiation dose and ranged from 58 to 91%. Regenerated shoots were obtained from all irradiated calli except those treated with 8 and 10 Gy. Shoot regeneration from the irradiated calli ranged from 8 to 50%, and gave 768 R{sub 1} plants. The highest regeneration of plants was obtained from calli treated with 3 Gy. These plants are being grown in a field for screening against red-rot and water-logged conditions. (author). 10 refs, 2 tabs.

  19. Magnetism Teaching Sequences Based on an Inductive Approach for First-Year Thai University Science Students

    Science.gov (United States)

    Narjaikaew, Pattawan; Emarat, Narumon; Arayathanitkul, Kwan; Cowie, Bronwen

    2010-01-01

    The study investigated the impact on student motivation and understanding of magnetism of teaching sequences based on an inductive approach. The study was conducted in large lecture classes. A pre- and post-Conceptual Survey of Electricity and Magnetism was conducted with just fewer than 700 Thai undergraduate science students, before and after…

  20. Change in magnetic induction lines during the current-induced destruction of superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Makiei, B; Golab, S; Sikora, A; Troinar, E; Zacharko, W [Polska Akademia Nauk, Wroclaw. Instytut Niskich Temperatur i Badan Strukturalnych

    1976-09-01

    Recent results of experimental investigations show that during the current-induced destruction of superconductivity in cylindrical samples a non-azimuthal component of the magnetic induction arises. This 'autoparamagnetic effect' is observable both in type I and type II superconductors. Assuming a helical form for the magnetic flux filaments the angle between the magnetic induction lines and the plane perpendicular to the Pb + In alloy sample axis is estimated in several cases. A conceptual explanation of the energy losses in the resistive state is.

  1. Change in magnetic induction lines during the current-induced destruction of superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Makiej, B; Golab, S; Sikora, A; Trojnar, E; Zacharko, W

    1976-09-01

    Recent results of experimental investigations show that during the current-induced destruction of superconductivity in cylindrical samples a non-azimuthal component of the magnetic induction arises. This ''autoparamagnetic effect'' is observable both in type I and type II superconductors. Assuming a helical form for the magnetic flux filaments the angle between the magnetic induction lines and the plane perpendicular to the Pb + In alloy sample axis is estimated in several cases. A conceptual explanation of the energy losses in the resistive state is presented. 4 refs.

  2. Neutron methods for the direct determination of the magnetic induction in thick films

    Energy Technology Data Exchange (ETDEWEB)

    Kozhevnikov, S.V., E-mail: kozhevn@nf.jinr.ru [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Ott, F. [CEA, IRAMIS, Laboratoire Léon Brillouin, F-91191 Gif sur Yvette (France); CNRS, IRAMIS, Laboratoire Léon Brillouin, F-91191 Gif sur Yvette (France); Radu, F. [Helmholtz-Zentrum Berlin für Materialien und Energie, Albert-Einstein Strasse 15, D-12489 Berlin (Germany)

    2016-03-15

    We review different neutron methods which allow extracting directly the value of the magnetic induction in thick films: Larmor precession, Zeeman spatial beam-splitting and neutron spin resonance. Resulting parameters obtained by the neutron methods and standard magnetometry technique are presented and compared. The possibilities and specificities of the neutron methods are discussed. - Highlights: • We present neutron methods for investigations of the thick magnetic films. • It is the methods for the direct determination of the magnetic induction. • Magnetic induction in bulk, at single interface and in a single domain. • It is Larmor precession, Zeeman spatial beam-splitting and neutron spin resonance. • These methods are complementary to polarized neutron reflectometry.

  3. High Tc superconducting nonlinear inductance and quick response magnetic sensor devices

    International Nuclear Information System (INIS)

    Uchiyama, T.; Mohri, K.; Ozeki, A.; Shibata, T.

    1990-01-01

    A flux penetration model considering the demagnetizing effect is presented in order to analyze the nonlinear inductance characteristics for HTcSC. Various quick response magnetic devices such as modulators, magnetic switches and magnetic sensors were constructed. The magnetizing frequency can be set up more than 10 MHz which is difficult to achieve with the conventional ferromagnetic bulk cores. The cut-off frequency of 1.6 MHz was obtained for the sensors using the HTcSC cores at a magnetizing frequency of 11.5 MHz

  4. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Zhang, Jun; Ouyang, Ziwei; Duffy, Maeve C.

    2014-01-01

    with a magnetic shunt by means of the stored magnetic energy in the primary and secondary sides of the transformer using the magnetomotive force (MMF) variation method, as well as the stored energy in the shunt based on the reluctance model. The detailed calculation method is described. Both the FEA simulation...

  5. Processing and display of nuclear magnetism logging signals: application to residual oil determination

    International Nuclear Information System (INIS)

    Brown, R.J.S.; Neuman, C.H.

    1980-01-01

    A presentation is made of a series of computations and signal displays which help to show the nature of NML signals in general as well as to show the response to particular formation, hole, and tool conditions. Such processing of digitally recorded signals enables improved accuracy and bed resolution over that presented with the raw log. The treatment of drilling mud filtrate to eliminate NML signal from the brine phase in the invaded zone is described. Logs are shown as recorded before and after invasion of treated mud filtrate. This treatment causes the NML signal to correspond to residual oil only, enabling accurate and relatively inexpensive measurement of residual oil. 24 refs

  6. Determination of the High Frequency Inductance Profile of Surface Mounted Permanent Magnet Synchronous Motors

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Rasmussen, Peter Omand; Ritchie, Ewen

    2008-01-01

    ) synchronous motors. This paper presents an AC+DC measurement method for determination of the d-axis and q-axis high frequency inductance profiles of SMPM synchronous motors. This method uses DC currents to set a desired magnetic working point on the motor laminations, and then superimpose balanced small AC......Accurate knowledge of the high frequency inductance profile plays an important role in many designs of sensorless controllers for Surface inductance. A special algorithm is used to decouple the cross-coupling effects between the d-axis and the q-axis, which allows Mounted Permanent Magnet (SMPM...... signals to measure the incremental a separate determination of the d, q inductance profiles as functions of the d, q currents. Experimental results on a commercial SMPM motor using the proposed method are presented in this paper....

  7. NdFeB magnets with zero temperature coefficient of induction

    International Nuclear Information System (INIS)

    Ma, B.M.; Narasimhan, K.S.V.L.; Hurt, J.C.

    1986-01-01

    Temperature compensation for the induction of NdFeB type magnets has been investigated. A computer assisted alloy selection method was adopted to identify composition of zero temperature coefficient of induction over -50 to 200 0 C. Selected alloys were processed into magnet by the conventional powder metallurgy method. The experimental temperature coefficient on the sintered magnet correlated with the prediction satisfactory. Holmium is an essential ingredient required for temperature compensation of NdFeB magnets. A magnet, (Nd/sub 0.23/Ho/sub 0.64/Dy/sub 0.13/)/sub 15/Fe/sub 79/B/sub 6/ with B/sub r/ of 7,700 Gauss, H/sub c/ of 7,700 Oe, H/sub ci/ of 20,600 Oe, Bh/sub max/ of 14.8 MGOe and temperature coefficient of -0.029% per 0 C over -50 to +150 was obtained

  8. Effect of coupling currents on the dynamic inductance during fast transient in superconducting magnets

    Directory of Open Access Journals (Sweden)

    V. Marinozzi

    2015-03-01

    Full Text Available We present electromagnetic models aiming to calculate the variation of the inductance in a magnet due to dynamic effects such as the variation of magnetization or the coupling with eddy currents. The models are studied with special regard to the calculation of the inductance in superconducting magnets which are affected by interfilament coupling currents. The developed models have been compared with experimental data coming from tests of prototype Nb_{3}Sn magnets designed for the new generation of accelerators. This work is relevant for the quench protection study of superconducting magnets: quench is an unwanted event, when part of the magnet becomes resistive; in these cases, the current should be discharged as fast as possible, in order to maintain the resistive zone temperature under a safe limit. The magnet inductance is therefore a relevant term for the description of the current discharge, especially for the high-field new generation superconducting magnets for accelerators, and this work shows how to calculate the correct value during rapid current changes, providing a mean for simulations of the reached temperature.

  9. Effects of electric field and magnetic induction on spin injection into organic semiconductors

    International Nuclear Information System (INIS)

    Wang, Y.M.; Ren, J.F.; Yuan, X.B.; Dou, Z.T.; Hu, G.C.

    2011-01-01

    Spin-polarized injection and transport into ferromagnetic/organic semiconductor structure are studied theoretically in the presence of the external electric field and magnetic induction. Based on the spin-drift-diffusion theory and Ohm's law, we obtain the charge current polarization, which takes into account the special carriers of organic semiconductors. From the calculation, it is found that the current spin polarization is enhanced by several orders of magnitude by tuning the magnetic induction and electric fields. To get an apparent current spin polarization, the effects of spin-depended interfacial resistances and the special carriers in the organic semiconductor, which are polarons and bipolarons, are also discussed. -- Research highlights: → Current polarization in ferromagnetic/organic semiconductor structure is obtained. → Calculations are based on spin-drift-diffusion theory and Ohm's law. → Current polarization is enhanced by tuning magnetic induction and electric fields. → Effects of interfacial resistances and the special carriers are also discussed.

  10. Direct and quadrature inductances measurement of the permanent magnetic linear synchronous machines

    Energy Technology Data Exchange (ETDEWEB)

    Li Liyi [Electrical Engineering Dept./Harbin Institute of Technology, Harbin 150000 (China); Hong Junjie, E-mail: wizard0663@126.co [School of Engineering/Sun Yat-Sen University, Guangzhou 510006 (China); Wu Hongxing; Kou Baoquan; Liu Rizhong [Electrical Engineering Dept./Harbin Institute of Technology, Harbin 150000 (China)

    2011-05-15

    Research highlights: {yields} The d- and q-axis inductances are derived theoretically. {yields} The new measurement principle of the d- and q-axis inductances is analyzed. {yields} A corresponding measuring circuit is developed. {yields} Measurement results match those of the FEM well. -- Abstract: Permanent magnetic linear synchronous machines (PMLSMs) are playing a more important role either in transportation systems or magnetic launch systems, for the excellent advantages. It is indispensable to high performance controllers that some machine parameters are known such as the direct axis (d-axis) and quadrature axis (q-axis) inductances. In this paper, self and mutual inductances of the three-phase winding are deduced by basic electric machinery theory, and the measured inductances are analyzed since the mutual inductances and the corresponding terminals among three-phase windings are changing as different phase winding is concerned. The d- and q-axis inductances are measured with the designed circuit, and the experimental measurement method is validated by the comparison between the experimental and finite element method (FEM) results.

  11. Direct and quadrature inductances measurement of the permanent magnetic linear synchronous machines

    International Nuclear Information System (INIS)

    Li Liyi; Hong Junjie; Wu Hongxing; Kou Baoquan; Liu Rizhong

    2011-01-01

    Research highlights: → The d- and q-axis inductances are derived theoretically. → The new measurement principle of the d- and q-axis inductances is analyzed. → A corresponding measuring circuit is developed. → Measurement results match those of the FEM well. -- Abstract: Permanent magnetic linear synchronous machines (PMLSMs) are playing a more important role either in transportation systems or magnetic launch systems, for the excellent advantages. It is indispensable to high performance controllers that some machine parameters are known such as the direct axis (d-axis) and quadrature axis (q-axis) inductances. In this paper, self and mutual inductances of the three-phase winding are deduced by basic electric machinery theory, and the measured inductances are analyzed since the mutual inductances and the corresponding terminals among three-phase windings are changing as different phase winding is concerned. The d- and q-axis inductances are measured with the designed circuit, and the experimental measurement method is validated by the comparison between the experimental and finite element method (FEM) results.

  12. Delineation of Salt Water Intrusion through Use of Electromagnetic-Induction Logging: A Case Study in Southern Manhattan Island, New York

    Directory of Open Access Journals (Sweden)

    Frederick Stumm

    2017-08-01

    Full Text Available Groundwater with chloride concentrations up to 15,000 mg/L has intruded the freshwater aquifer underlying southern Manhattan Island, New York. Historical (1940–1950 chloride concentration data of glacial aquifer wells in the study area indicate the presence of four wedges of saltwater intrusion that may have been caused by industrial pumpage. The limited recharge capability of the aquifer, due to impervious surfaces and the 22.7 million liters per day (mld of reported industrial pumpage early in the 20th Century was probably the cause for the saltwater intrusion and the persistence of the historical saltwater intrusion wedges over time. Recent drilling of wells provided new information on the hydrogeology and extent of saltwater intrusion of the glacial aquifer overlying bedrock. The new observation wells provided ground-water level, chloride concentration, hydraulic conductivity, and borehole geophysical data of the glacial aquifer. The glacial sediments range in thickness from less than 0.3 m to more than 76.2 m within the study area. A linear relation between Electromagnetic-induction (EM conductivity log response and measured chloride concentration was determined. Using this relation, chloride concentration was estimated in parts of the glacial aquifer where sampling was not possible. EM logging is an effective tool to monitor changes in saltwater intrusion wedges.

  13. Comparison of an Inductance In-Line Oil Debris Sensor and Magnetic Plug Oil Debris Sensor

    Science.gov (United States)

    Dempsey, Paula J.; Tuck, Roger; Showalter, Stephen

    2012-01-01

    The objective of this research was to compare the performance of an inductance in-line oil debris sensor and magnetic plug oil debris sensor when detecting transmission component health in the same system under the same operating conditions. Both sensors were installed in series in the NASA Glenn Spiral Bevel Gear Fatigue Rig during tests performed on 5 gear sets (pinion/gear) when different levels of damage occurred on the gear teeth. Results of this analysis found both the inductance in-line oil debris sensor and magnetic plug oil debris sensor have benefits and limitations when detecting gearbox component damage.

  14. Phase-Inductance-Based Position Estimation Method for Interior Permanent Magnet Synchronous Motors

    Directory of Open Access Journals (Sweden)

    Xin Qiu

    2017-12-01

    Full Text Available This paper presents a phase-inductance-based position estimation method for interior permanent magnet synchronous motors (IPMSMs. According to the characteristics of phase induction of IPMSMs, the corresponding relationship of the rotor position and the phase inductance is obtained. In order to eliminate the effect of the zero-sequence component of phase inductance and reduce the rotor position estimation error, the phase inductance difference is employed. With the iterative computation of inductance vectors, the position plane is further subdivided, and the rotor position is extracted by comparing the amplitudes of inductance vectors. To decrease the consumption of computer resources and increase the practicability, a simplified implementation is also investigated. In this method, the rotor position information is achieved easily, with several basic math operations and logical comparisons of phase inductances, without any coordinate transformation or trigonometric function calculation. Based on this position estimation method, the field orientated control (FOC strategy is established, and the detailed implementation is also provided. A series of experiment results from a prototype demonstrate the correctness and feasibility of the proposed method.

  15. Impact of magnetic saturation on the input-output linearising tracking control of an induction motor

    DEFF Research Database (Denmark)

    Dolinar, Drago; Ljusev, Petar; Stumberger, Gorazd

    2004-01-01

    This paper deals with the tracking control design of an induction motor, based on input-output linearization with magnetic saturation included. Magnetic saturation is represented by the nonlinear magnetizing curve of the iron core and is used in the control design, the observer of state variables......, and in the load torque estimator. An input-output linearising control is used to achieve better tracking performances of the drive. It is based on the mixed ”stator current - rotor flux linkage” induction motor model with magnetic saturation considered in the stationary reference frame. Experimental results show...... that the proposed input-output linearising tracking control with the included saturation behaves considerably better than the one without saturation, and that it introduces smaller position and speed errors, and better motor stiffness on account of the increased computational complexity....

  16. Reducing the Lift-Off Effect on Permeability Measurement for Magnetic Plates From Multifrequency Induction Data

    OpenAIRE

    Lu, Mingyang; Zhu, Wenqian; Yin, Liyuan; Peyton, Anthony J.; Yin, Wuliang; Qu, Zhigang

    2017-01-01

    Lift-off variation causes errors in eddy current measurement of nonmagnetic plates as well as magnetic plates. For nonmagnetic plates, previous work has been carried out to address the issue. In this paper, we follow a similar strategy, but try to reduce the lift-off effect on another index--zero-crossing frequency for magnetic plates. This modified index, termed as the compensated zero-crossing frequency, can be obtained from the measured multifrequency inductance spectral data using the alg...

  17. Propagation of ULF waves through the ionosphere: Inductive effect for oblique magnetic fields

    Directory of Open Access Journals (Sweden)

    M. D. Sciffer

    2004-04-01

    Full Text Available Solutions for ultra-low frequency (ULF wave fields in the frequency range 1–100mHz that interact with the Earth's ionosphere in the presence of oblique background magnetic fields are described. Analytic expressions for the electric and magnetic wave fields in the magnetosphere, ionosphere and atmosphere are derived within the context of an inductive ionosphere. The inductive shielding effect (ISE arises from the generation of an "inductive" rotational current by the induced part of the divergent electric field in the ionosphere which reduces the wave amplitude detected on the ground. The inductive response of the ionosphere is described by Faraday's law and the ISE depends on the horizontal scale size of the ULF disturbance, its frequency and the ionosphere conductivities. The ISE for ULF waves in a vertical background magnetic field is limited in application to high latitudes. In this paper we examine the ISE within the context of oblique background magnetic fields, extending studies of an inductive ionosphere and the associated shielding of ULF waves to lower latitudes. It is found that the dip angle of the background magnetic field has a significant effect on signals detected at the ground. For incident shear Alfvén mode waves and oblique background magnetic fields, the horizontal component of the field-aligned current contributes to the signal detected at the ground. At low latitudes, the ISE is larger at smaller conductivity values compared with high latitudes.

    Key words. Ionosphere (ionosphere-magnetosphere interactions; electric fields and currents; wave propagation

  18. Superconducting magnets for induction linac phase-rotation in a neutrino factory

    International Nuclear Information System (INIS)

    Green, M.A.; Yu, S.

    2001-01-01

    The neutrino factory[1-3] consists of a target section where pions are produced and captured in a solenoidal magnetic field. Pions in a range of energies from 100 Mev to 400 MeV decay into muons in an 18-meter long channel of 1.25 T superconducting solenoids. The warm bore diameter of these solenoids is about 600 mm. The phase rotation section slows down the high-energy muon and speeds up the low energy muons to an average momentum of 200 MeV/c. The phase-rotation channel consists of three induction linac channels with a short cooling section and a magnetic flux reversal section between the first and second induction linacs and a drift space between the second and third induction linacs. The length of the phase rotation channel will be about 320 meters. The superconducting coils in the channel are 0.36 m long with a gap of 0.14 m between the coils. The magnetic induction within the channel will be 1.25. For 260 meters of the 320-meter long channel, the solenoids are inside the induction linac. This paper discusses the design parameters for the superconducting solenoids in the neutrino factory phase-rotation channel

  19. Temperature Dependence and Magnetic Properties of Injection Molding Tool Materials Used in Induction Heating

    DEFF Research Database (Denmark)

    Guerrier, Patrick; Nielsen, Kaspar Kirstein; Hattel, Jesper Henri

    2015-01-01

    To analyze the heating phase of an induction heated injection molding tool precisely, the temperature-dependent magnetic properties, B–H curves, and the hysteresis loss are necessary for the molding tool materials. Hence, injection molding tool steels, core materials among other materials have...

  20. Start-up problem with an induction machine and a permanent magnet gear

    DEFF Research Database (Denmark)

    Frandsen, Tommy; Berg, Nick Ilsø; Holm, Rasmus Koldborg

    2014-01-01

    This paper presents the preliminary work conducted to design a magnetic gear (MG) integrated with a fan and driven by an grid connected induction machine (IM). A start-up problem with a MG, which occurs due to a high oscillating torque and a high breakdown torque of the IM when starting up directly...

  1. Analytic solution of magnetic induction distribution of ideal hollow spherical field sources

    Science.gov (United States)

    Xu, Xiaonong; Lu, Dingwei; Xu, Xibin; Yu, Yang; Gu, Min

    2017-12-01

    The Halbach type hollow spherical permanent magnet arrays (HSPMA) are volume compacted, energy efficient field sources, and capable of producing multi-Tesla field in the cavity of the array, which have attracted intense interests in many practical applications. Here, we present analytical solutions of magnetic induction to the ideal HSPMA in entire space, outside of array, within the cavity of array, and in the interior of the magnet. We obtain solutions using concept of magnetic charge to solve the Poisson's and Laplace's equations for the HSPMA. Using these analytical field expressions inside the material, a scalar demagnetization function is defined to approximately indicate the regions of magnetization reversal, partial demagnetization, and inverse magnetic saturation. The analytical field solution provides deeper insight into the nature of HSPMA and offer guidance in designing optimized one.

  2. Multilevel DC Link Inverter for Brushless Permanent Magnet Motors with Very Low Inductance

    International Nuclear Information System (INIS)

    Su, G.J.

    2001-01-01

    Due to their long effective air gaps, permanent magnet motors tend to have low inductance. The use of ironless stator structure in present high power PM motors (several tens of kWs) reduces the inductance even further ( and lt; 100(micro)H). This low inductance imposes stringent current regulation demands for the inverter to obtain acceptable current ripple. An analysis of the current ripple for these low inductance brushless PM motors shows that a standard inverter with the most commonly used IGBT switching devices cannot meet the current regulation demands and will produce unacceptable current ripples due to the IGBT's limited switching frequency. This paper introduces a new multilevel dc link inverter, which can dramatically reduce the current ripple for brushless PM motor drives. The operating principle and design guidelines are included

  3. An Induction Heating Method with Traveling Magnetic Field for Long Structure Metal

    Science.gov (United States)

    Sekine, Takamitsu; Tomita, Hideo; Obata, Shuji; Saito, Yukio

    A novel dismantlable adhesion method for recycling operation of interior materials is proposed. This method is applied a high frequency induction heating and a thermoplastic adhesive. For an adhesion of interior material to long steel stud, a conventional spiral coil as like IH cooking heater gives inadequateness for uniform heating to the stud. Therefore, we have proposed an induction heating method with traveling magnetic field for perfect long structures bonding. In this paper, we describe on the new adhesion method using the 20kHz, three-phase 200V inverter and linear induction coil. From induction heating characteristics to thin steel plates and long studs, the method is cleared the usefulness for uniform heating to long structures.

  4. The effect of the novel internal-type linear inductive antenna for large area magnetized inductive plasma source

    Science.gov (United States)

    Lee, S. H.; Shulika, Olga.; Kim, K. N.; Yeom, G. Y.; Lee, J. K.

    2004-09-01

    As the technology of plasma processing progresses, there is a continuing demand for higher plasma density, uniformity over large areas and greater control over plasma parameters to optimize the processes of etching, deposition and surface treatment. Traditionally, the external planar ICP sources with low pressure high density plasma have limited scale-up capabilities due to its high impedance accompanied by the large antenna size. Also due to the cost and thickness of their dielectric material in order to generate uniform plasma. In this study the novel internal-type linear inductive antenna system (1,020mm¡¿830mm¡¿437mm) with permanent magnet arrays are investigated to improve both the plasma density and the uniformity of LAPS (Large Area Plasma Source) for FPD processing. Generally plasma discharges are enhanced because the inductance of the novel antenna (termed as the double comb antenna) is lower than that of the serpentine-type antenna and also the magnetic confinement of electron increases the power absorption efficiency. The uniformity is improved by reducing the standing wave effect. The total length of antenna is comparable to the driving rf wavelength to cause the plasma nonuniformity. To describe the discharge phenomenon we have developed a magnetized two-dimensional fluid simulation. This work was supported by National Research Laboratory (NRL) Program of the Korea Ministry of Science and Technology. [References] 1. J.K.Lee, Lin Meng, Y.K.Shin, H,J,Lee and T.H.Chung, ¡°Modeling and Simulation of a Large-Area Plasma Source¡±, Jpn. J. Appl. Phys. Vol.36(1997) pp. 5714-5723 2. S.E.Park, B.U.Cho, Y.J.Lee*, and G.Y.Yeom*, and J.K.Lee, ¡°The Characteristics of Large Area Processing Plasmas¡±, IEEE Trans. Plasma Sci., Vol.31 ,No.4(2003) pp. 628-637

  5. Performance Comparison between a Permanent Magnet Synchronous Motor and an Induction Motor as a Traction Motor for High Speed Train

    Science.gov (United States)

    Kondo, Minoru; Kawamura, Junya; Terauchi, Nobuo

    Performance tests are carried out to demonstrate the superiority of a permanent magnet synchronous motor to an induction motor as a traction motor for high-speed train. A prototype motor was manufactured by replacing the rotor of a conventional induction motor. The test results show that the permanent magnet motor is lighter, efficient and more silent than the induction motor because of the different rotor structure.

  6. Development of the methodology for the MHD analysis in a linear induction electro-magnetic pump

    International Nuclear Information System (INIS)

    Seong, Seung Hwan; Hur, Seop; Kim, Seong O; Choi, Seok Ki; Wi, Myung Hwan; Jeon, Won Dae

    2004-01-01

    Generally, fast breeder reactors have adopted a liquid metal as a coolant for the heat transfer from the reactor to the heat exchangers. Since a liquid metal has an electrical conductivity, the pumping of the liquid metal may use an induction electro-magnetic (EM) pump which induces electrical current and body force on the metal flow. These linear induction pumps use a traveling magnetic field wave created by poly-phase currents and the induced currents and their associated magnetic field generate the Lorentz force whose effect can be actually the pumping of the liquid metal. The flow behaviors in the pump are very complex such as the existence of a rotational force, pulsation and so on, because the induction EM pump has time-varying magnetic fields and the induced convective currents which originate form the flow of the liquid metal. These phenomena generate a stability problem in the pump and depend on the changes of the magnetic field and fluid flow field due to the induced currents and the fluid flow of the liquid metal with time and complex pump geometry. Therefore, an exact flow analysis is required for designing and evaluating the stability of a pump

  7. Modeling of Self-Excited Isolated Permanent Magnet Induction Generator Using Iterative Numerical Method

    Directory of Open Access Journals (Sweden)

    Mohamed Mostafa R.

    2016-01-01

    Full Text Available Self-Excited Permanent Magnet Induction Generator (PMIG is commonly used in wind energy generation systems. The difficulty of Self-Excited Permanent Magnet Induction Generator (SEPMIG modeling is the circuit parameters of the generator vary at each load conditions due to the a change in the frequency and stator voltage. The paper introduces a new modeling for SEPMIG using Gauss-sidle relaxation method. The SEPMIG characteristics using the proposed method are studied at different load conditions according to the wind speed variation, load impedance changes and different shunted capacitor values. The system modeling is investigated due to the magnetizing current variation, the efficiency variation, the power variation and power factor variation. The proposed modeling system satisfies high degree of simplicity and accuracy.

  8. Input-output linearizing tracking control of induction machine with the included magnetic saturation

    DEFF Research Database (Denmark)

    Dolinar, Drago; Ljusev, Petar; Stumberger, Gorazd

    2003-01-01

    The tracking control design of an induction motor, based on input-output linearisation with magnetic saturation included is addressed. The magnetic saturation is represented by a nonlinear magnetising curve for the iron core and is used in the control, the observer of the state variables......, and in the load torque estimator. An input-output linearising control is used to achieve better tracking performances. It is based on the mixed 'stator current - rotor flux linkage' induction motor model with magnetic saturation considered in the stationary reference frame. Experimental results show...... that the proposed input-output linearising tracking control with saturation included behaves considerably better than the one without saturation, and that it introduces smaller position and speed errors, and better motor stiffness on account of the increased computational complexity....

  9. Ironless Inductive Position Sensor for Harsh Magnetic Environments

    CERN Document Server

    Danisi, Alessandro; Masi, Alessandro

    Linear Variable Differential Transformers (LVDTs) are widely used for high-precision and high-accuracy linear position sensing in harsh environments, such as the LHC collimators at CERN. These sensors guarantee theoretically infinite resolution and long lifetimes thanks to contactless sensing. Furthermore, they offer very good robustness and ruggedness, as well as micrometer uncertainty over a range of centimeters when proper conditioning techniques are used (such as the three-parameter Sine-Fit algorithm). They can also be suitable for radioactive environments. Nevertheless, an external DC/slowly-varying magnetic field can seriously affect the LVDT reading, leading to position drifts of hundreds of micrometers, often unacceptable in high-accuracy applications. The effect is due to the presence of non-linear ferromagnetic materials in the sensor’s structure. A detailed Finite Element model of an LVDT is first proposed in order to study and characterize the phenomenon. The model itself becomes a powerful de...

  10. Use of magnetic compression based on amorphous alloys as a drive for induction linacs

    International Nuclear Information System (INIS)

    Birx, D.L.; Cook, E.G.; Hawkins, S.A.; Poor, S.E.; Reginato, L.; Schmidt, J.; Smith, M.W.

    1984-01-01

    In anticipation of current and future needs for the Particle Beam Program and other programs at the Lawrence Livermore National Laboratory, we are continuing efforts in the development of high-repetition-rate magnetic pulse compressors that use ferromagnetic metallic glasses, both in the linear and very high saturation rates. These devices are ideally suited as drivers for linear induction accelerators, where duty factor or average repetition rates (hundred of hertz) requirements exceed the parameters that can be achieved by pulse compression using spark gaps. The technique of magnetic pulse compression has been with use for several decades, but relatively recent developments in rapidly quenched magnetic metals of very thin cross sections, has led to the development of state-of-the-art magnetic pulse compressors with very high peak power, repetition rates, and reliability. This paper will describe results of recent experiments and the relevant electrical and mechanical properties of magnetic pulse compressors to achieve high efficiency and reliability

  11. The effects of extremely low frequency magnetic fields on mutation induction in mice

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, James W. [Department of Genetics, University of Leicester, Leicester LE1 7RH (United Kingdom); Haines, Jackie; Sienkiewicz, Zenon [Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton, Didcot, Oxfordshire OX11 0RQ (United Kingdom); Dubrova, Yuri E., E-mail: yed2@le.ac.uk [Department of Genetics, University of Leicester, Leicester LE1 7RH (United Kingdom)

    2015-03-15

    Highlights: • The effects of 50 Hz magnetic fields on mutation induction in mice were analyzed. • The frequency of ESTR mutation was established in sperm and blood. • Exposure to 10–300 μT for 2 and 15 h did not result in mutation induction. • Mutagenic effects of 50 Hz magnetic fields are likely to be negligible. - Abstract: The growing human exposure to extremely low frequency (ELF) magnetic fields has raised a considerable concern regarding their genotoxic effects. The aim of this study was to evaluate the in vivo effects of ELF magnetic fields irradiation on mutation induction in the germline and somatic tissues of male mice. Seven week old BALB/c × CBA/Ca F{sub 1} hybrid males were exposed to 10, 100 or 300 μT of 50 Hz magnetic fields for 2 or 15 h. Using single-molecule PCR, the frequency of mutation at the mouse Expanded Simple Tandem Repeat (ESTR) locus Ms6-hm was established in sperm and blood samples of exposed and matched sham-treated males. ESTR mutation frequency was also established in sperm and blood samples taken from male mice exposed to 1 Gy of acute X-rays. The frequency of ESTR mutation in DNA samples extracted from blood of mice exposed to magnetic fields did not significantly differ from that in sham-treated controls. However, there was a marginally significant increase in mutation frequency in sperm but this was not dose-dependent. In contrast, acute exposure X-rays led to significant increases in mutation frequency in sperm and blood of exposed males. The results of our study suggest that, within the range of doses analyzed here, the in vivo mutagenic effects of ELF magnetic fields are likely to be minor if not negligible.

  12. The effects of extremely low frequency magnetic fields on mutation induction in mice

    International Nuclear Information System (INIS)

    Wilson, James W.; Haines, Jackie; Sienkiewicz, Zenon; Dubrova, Yuri E.

    2015-01-01

    Highlights: • The effects of 50 Hz magnetic fields on mutation induction in mice were analyzed. • The frequency of ESTR mutation was established in sperm and blood. • Exposure to 10–300 μT for 2 and 15 h did not result in mutation induction. • Mutagenic effects of 50 Hz magnetic fields are likely to be negligible. - Abstract: The growing human exposure to extremely low frequency (ELF) magnetic fields has raised a considerable concern regarding their genotoxic effects. The aim of this study was to evaluate the in vivo effects of ELF magnetic fields irradiation on mutation induction in the germline and somatic tissues of male mice. Seven week old BALB/c × CBA/Ca F 1 hybrid males were exposed to 10, 100 or 300 μT of 50 Hz magnetic fields for 2 or 15 h. Using single-molecule PCR, the frequency of mutation at the mouse Expanded Simple Tandem Repeat (ESTR) locus Ms6-hm was established in sperm and blood samples of exposed and matched sham-treated males. ESTR mutation frequency was also established in sperm and blood samples taken from male mice exposed to 1 Gy of acute X-rays. The frequency of ESTR mutation in DNA samples extracted from blood of mice exposed to magnetic fields did not significantly differ from that in sham-treated controls. However, there was a marginally significant increase in mutation frequency in sperm but this was not dose-dependent. In contrast, acute exposure X-rays led to significant increases in mutation frequency in sperm and blood of exposed males. The results of our study suggest that, within the range of doses analyzed here, the in vivo mutagenic effects of ELF magnetic fields are likely to be minor if not negligible

  13. Induction-heating MOCVD reactor with significantly improved heating efficiency and reduced harmful magnetic coupling

    KAUST Repository

    Li, Kuang-Hui; Alotaibi, Hamad S.; Sun, Haiding; Lin, Ronghui; Guo, Wenzhe; Torres-Castanedo, Carlos G.; Liu, Kaikai; Galan, Sergio V.; Li, Xiaohang

    2018-01-01

    In a conventional induction-heating III-nitride metalorganic chemical vapor deposition (MOCVD) reactor, the induction coil is outside the chamber. Therefore, the magnetic field does not couple with the susceptor well, leading to compromised heating efficiency and harmful coupling with the gas inlet and thus possible overheating. Hence, the gas inlet has to be at a minimum distance away from the susceptor. Because of the elongated flow path, premature reactions can be more severe, particularly between Al- and B-containing precursors and NH3. Here, we propose a structure that can significantly improve the heating efficiency and allow the gas inlet to be closer to the susceptor. Specifically, the induction coil is designed to surround the vertical cylinder of a T-shaped susceptor comprising the cylinder and a top horizontal plate holding the wafer substrate within the reactor. Therefore, the cylinder coupled most magnetic field to serve as the thermal source for the plate. Furthermore, the plate can block and thus significantly reduce the uncoupled magnetic field above the susceptor, thereby allowing the gas inlet to be closer. The results show approximately 140% and 2.6 times increase in the heating and susceptor coupling efficiencies, respectively, as well as a 90% reduction in the harmful magnetic flux on the gas inlet.

  14. Induction-heating MOCVD reactor with significantly improved heating efficiency and reduced harmful magnetic coupling

    KAUST Repository

    Li, Kuang-Hui

    2018-02-23

    In a conventional induction-heating III-nitride metalorganic chemical vapor deposition (MOCVD) reactor, the induction coil is outside the chamber. Therefore, the magnetic field does not couple with the susceptor well, leading to compromised heating efficiency and harmful coupling with the gas inlet and thus possible overheating. Hence, the gas inlet has to be at a minimum distance away from the susceptor. Because of the elongated flow path, premature reactions can be more severe, particularly between Al- and B-containing precursors and NH3. Here, we propose a structure that can significantly improve the heating efficiency and allow the gas inlet to be closer to the susceptor. Specifically, the induction coil is designed to surround the vertical cylinder of a T-shaped susceptor comprising the cylinder and a top horizontal plate holding the wafer substrate within the reactor. Therefore, the cylinder coupled most magnetic field to serve as the thermal source for the plate. Furthermore, the plate can block and thus significantly reduce the uncoupled magnetic field above the susceptor, thereby allowing the gas inlet to be closer. The results show approximately 140% and 2.6 times increase in the heating and susceptor coupling efficiencies, respectively, as well as a 90% reduction in the harmful magnetic flux on the gas inlet.

  15. Investigation on magnetoacoustic signal generation with magnetic induction and its application to electrical conductivity reconstruction

    International Nuclear Information System (INIS)

    Ma Qingyu; He Bin

    2007-01-01

    A theoretical study on the magnetoacoustic signal generation with magnetic induction and its applications to electrical conductivity reconstruction is conducted. An object with a concentric cylindrical geometry is located in a static magnetic field and a pulsed magnetic field. Driven by Lorentz force generated by the static magnetic field, the magnetically induced eddy current produces acoustic vibration and the propagated sound wave is received by a transducer around the object to reconstruct the corresponding electrical conductivity distribution of the object. A theory on the magnetoacoustic waveform generation for a circular symmetric model is provided as a forward problem. The explicit formulae and quantitative algorithm for the electrical conductivity reconstruction are then presented as an inverse problem. Computer simulations were conducted to test the proposed theory and assess the performance of the inverse algorithms for a multi-layer cylindrical model. The present simulation results confirm the validity of the proposed theory and suggest the feasibility of reconstructing electrical conductivity distribution based on the proposed theory on the magnetoacoustic signal generation with magnetic induction

  16. Analysis of Unbalanced Magnetic Pull in Wound Rotor Induction Machines using Finite Element Analysis – Transient, Motoring and Generating Modes

    DEFF Research Database (Denmark)

    Dorrell, David G.; Hermann, Alexander Niels August; Jensen, Bogi Bech

    2013-01-01

    eccentricity. The operating conditions are varied so that transient, motoring and doubly-fed induction generator modes are studied. This allows greater understanding of the radial forces involved. Wound rotor induction machines exhibit higher unbalanced magnetic pull than cage induction machines so......There has been much literature on unbalanced magnetic pull in various types of electrical machine. This can lead to bearing wear and additional vibrations in the machine. In this paper a wound rotor induction is studied. Finite element analysis studies are conducted when the rotor has 10 % rotor...

  17. A Magnetic-Balanced Inductive Link for the Simultaneous Uplink Data and Power Telemetry.

    Science.gov (United States)

    Gong, Chen; Liu, Dake; Miao, Zhidong; Li, Min

    2017-08-02

    When using the conventional two-coil inductive link for the simultaneous wireless power and data transmissions in implantable biomedical sensor devices, the strong power carrier could overwhelm the uplink data signal and even saturate the external uplink receiver. To address this problem, we propose a new magnetic-balanced inductive link for our implantable glaucoma treatment device. In this inductive link, an extra coil is specially added for the uplink receiving. The strong power carrier interference is minimized to approach zero by balanced canceling of the magnetic field of the external power coil. The implant coil is shared by the wireless power harvesting and the uplink data transmitting. Two carriers (i.e., 2-MHz power carrier and 500-kHz uplink carrier) are used for the wireless power transmission and the uplink data transmission separately. In the experiments, the prototype of this link achieves as high as 65.72 dB improvement of the signal-to-interference ratio (SIR) compared with the conventional two-coil inductive link. Benefiting from the significant improvement of SIR, the implant transmitter costs only 0.2 mW of power carrying 50 kbps of binary phase shift keying data and gets a bit error rate of 1 × 10 - 7 , even though the coupling coefficient is as low as 0.005. At the same time, 5 mW is delivered to the load with maximum power transfer efficiency of 58.8%. This magnetic-balanced inductive link is useful for small-sized biomedical sensor devices, which require transmitting data and power simultaneously under ultra-weak coupling.

  18. A Magnetic-Balanced Inductive Link for the Simultaneous Uplink Data and Power Telemetry

    Directory of Open Access Journals (Sweden)

    Chen Gong

    2017-08-01

    Full Text Available When using the conventional two-coil inductive link for the simultaneous wireless power and data transmissions in implantable biomedical sensor devices, the strong power carrier could overwhelm the uplink data signal and even saturate the external uplink receiver. To address this problem, we propose a new magnetic-balanced inductive link for our implantable glaucoma treatment device. In this inductive link, an extra coil is specially added for the uplink receiving. The strong power carrier interference is minimized to approach zero by balanced canceling of the magnetic field of the external power coil. The implant coil is shared by the wireless power harvesting and the uplink data transmitting. Two carriers (i.e., 2-MHz power carrier and 500-kHz uplink carrier are used for the wireless power transmission and the uplink data transmission separately. In the experiments, the prototype of this link achieves as high as 65.72 dB improvement of the signal-to-interference ratio (SIR compared with the conventional two-coil inductive link. Benefiting from the significant improvement of SIR, the implant transmitter costs only 0.2 mW of power carrying 50 kbps of binary phase shift keying data and gets a bit error rate of 1 × 10 − 7 , even though the coupling coefficient is as low as 0.005. At the same time, 5 mW is delivered to the load with maximum power transfer efficiency of 58.8%. This magnetic-balanced inductive link is useful for small-sized biomedical sensor devices, which require transmitting data and power simultaneously under ultra-weak coupling.

  19. Performance exploration of an energy harvester near the varying magnetic field of an operating induction motor

    International Nuclear Information System (INIS)

    Uzun, Yunus; Kurt, Erol

    2013-01-01

    Highlights: • This paper explores the piezoelectric harvester performance. • The varying magnetic field generates electricity via exciting harvester. • Generated power should be optimized via load resistance. • 0.11 mW/cm 3 Power can be generated from 500 cm 3 surrounding volume. - Abstract: This paper reports a performance exploration of a piezoelectric harvester which is positioned near an operating induction motor. The harvester includes a magnet knob in a pendulum arrangement, which ascertains mechanical vibrations under the varying magnetic field. This energy harvester transforms the ambient unused magnetic energy into the electricity due to the piezoelectric layer attached to the pendulum. It has been proven that when the motor is under operation, the varying ambient field causes a varying magnetic force at the tip of harvester, then output voltage between the terminals of piezoelectric layer is produced due to the mechanical vibrations. This output signal has some characteristics of the operating induction motor in terms of its operation frequency, number of magnetic pole and natural frequency of the harvester. Since the surrounding field of the induction motor directly depends on the current flowing through the windings and electrical parameters, both the amplitude U and the frequency ω m of the harvested voltage can be characterized after some certain parametrical explorations. It has been proven that the harvested voltage strictly depends on the electrical load, which is attached to the terminals of the harvester, after the rectifying circuit. The harvested power per surrounding volume can be increased up to 0.11 mW/cm 3 , if the entire surrounding volume of the motor is considered

  20. Study on spatial distribution of plasma parameters in a magnetized inductively coupled plasma

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Hee-Woon; Lee, Woohyun; Kim, Ji-Won; Whang, Ki-Woong, E-mail: kwhang@snu.ac.kr [Plasma Laboratory, Inter-University Semiconductor Research Center, Department of Electrical and Computer Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Kim, Hyuk [Samsung Electronics Co., Banwol-dong, Hwaseong 445-701 (Korea, Republic of); Park, Wanjae [Tokyo Electron Miyagi Ltd., Taiwa-cho, Kurokawa-gun, Miyagi 981-3629 (Japan)

    2015-07-15

    Spatial distributions of various plasma parameters such as plasma density, electron temperature, and radical density in an inductively coupled plasma (ICP) and a magnetized inductively coupled plasma (M-ICP) were investigated and compared. Electron temperature in between the rf window and the substrate holder of M-ICP was higher than that of ICP, whereas the one just above the substrate holder of M-ICP was similar to that of ICP when a weak (<8 G) magnetic field was employed. As a result, radical densities in M-ICP were higher than those in ICP and the etch rate of oxide in M-ICP was faster than that in ICP without severe electron charging in 90 nm high aspect ratio contact hole etch.

  1. Speed control of switched reluctance motors taking into account mutual inductances and magnetic saturation effects

    Energy Technology Data Exchange (ETDEWEB)

    Alrifai, M., E-mail: alrifm@eng.kuniv.edu.k [Electrical Engineering Department, College of Engineering and Petroleum, Kuwait University, P.O. Box 5969, Safat 13060 (Kuwait); Zribi, M.; Rayan, M. [Electrical Engineering Department, College of Engineering and Petroleum, Kuwait University, P.O. Box 5969, Safat 13060 (Kuwait); Krishnan, R. [Center for Rapid Transit Systems, Electrical and Computer Engineering Department, Virginia Tech University, 461 Durham Hall, Blacksburg, VA 24061-011 (United States)

    2010-06-15

    This paper deals with the speed control of switched reluctance motor (SRM) drives taking into account the effects of the mutual inductances between two adjacent phases and the effects of the magnetic saturation of the core. To overcome the problems commonly associated with single-phase excitation, a nonlinear SRM model, which is suitable for two-phase excitation and which takes into account the effects of mutual inductances between two adjacent phases and the magnetic saturation effects, is considered in the design of the proposed controllers. A feedback linearization control scheme and a sliding mode control scheme are designed for this motor drive. The proposed controllers guarantee the convergence of the phase currents and the rotor speed of the motor to their desired values. Simulation results indicate that the proposed controllers work well and that they are robust to changes in the parameters of the system and to changes in the load torque.

  2. Speed control of switched reluctance motors taking into account mutual inductances and magnetic saturation effects

    International Nuclear Information System (INIS)

    Alrifai, M.; Zribi, M.; Rayan, M.; Krishnan, R.

    2010-01-01

    This paper deals with the speed control of switched reluctance motor (SRM) drives taking into account the effects of the mutual inductances between two adjacent phases and the effects of the magnetic saturation of the core. To overcome the problems commonly associated with single-phase excitation, a nonlinear SRM model, which is suitable for two-phase excitation and which takes into account the effects of mutual inductances between two adjacent phases and the magnetic saturation effects, is considered in the design of the proposed controllers. A feedback linearization control scheme and a sliding mode control scheme are designed for this motor drive. The proposed controllers guarantee the convergence of the phase currents and the rotor speed of the motor to their desired values. Simulation results indicate that the proposed controllers work well and that they are robust to changes in the parameters of the system and to changes in the load torque.

  3. Sensitive element of multifunctional sensor for measuring temperature, strain and magnetic field induction

    Directory of Open Access Journals (Sweden)

    Druzhinin A. A.

    2017-12-01

    Full Text Available Sensitive element of multifunctional sensor for measuring temperature, strain and magnetic field induction has been developed based on the studies of electrical conductivity and magnetoresistance of silicon and germanium microcrystals in the temperature range 4.2—70 K, strain ±1.5*10–3 rel.un. and magnetic fields of 0—14 T. The feature of the sensitive element is the using of the p- and n-type conductivity germanium microcrystals as mechanical and magnetic field sensors, respectively, and the p-type silicon microcrystal — as temperature sensor. That allows providing the compensation of temperature influence on piezoresistance and on sensitivity to the magnetic field.

  4. Numerical Simulation of the Moving Induction Heating Process with Magnetic Flux Concentrator

    Directory of Open Access Journals (Sweden)

    Feng Li

    2013-01-01

    Full Text Available The induction heating with ferromagnetic metal powder bonded magnetic flux concentrator (MPB-MFC demonstrates more advantages in surface heating treatments of metal. However, the moving heating application is mostly applied in the industrial production. Therefore, the analytical understanding of the mechanism, efficiency, and controllability of the moving induction heating process becomes necessary for process design and optimization. This paper studies the mechanism of the moving induction heating with magnetic flux concentrator. The MPB-MFC assisted moving induction heating for Inconel 718 alloy is studied by establishing the finite element simulation model. The temperature field distribution is analyzed, and the factors influencing the temperature are studied. The conclusion demonstrates that the velocity of the workpiece should be controlled properly and the heat transfer coefficient (HTC has little impact on the temperature development, compared with other input parameters. In addition, the validity of the static numerical model is verified by comparing the finite element simulation with experimental results on AISI 1045 steel. The numerical model established in this work can provide comprehensive understanding for the process control in production.

  5. A new kind of low-inductance transformer type magnetic switch (TTMS) with coaxial cylindrical conductors.

    Science.gov (United States)

    Zhang, Yu; Liu, Jinliang

    2013-02-01

    As important devices for voltage boosting and switching, respectively, pulse transformer and magnetic switch are widely used in pulsed power technology. In this paper, a new kind of transformer type magnetic switch (TTMS) with coaxial cylindrical conductors is put forward to combine the functions of voltage boosting and switching in one power device. As a compact combination device of discrete pulse transformer and magnetic switch, the compact TTMS decreases the required volume of magnetic cores in a large scale. The primary windings of the TTMS have a parallel combination structure so that the TTMS which only has 3 turns of secondary windings has a step-up ratio at 1:9. Before the magnetic core saturates, the TTMS has low unsaturated inductances of windings and good pulse response characteristics, so it can be used to substitute the Marx generator to charge the pulse forming line (PFL) at the ranges of several hundred kV and several hundred ns. After the core saturates, the cylindrical conductors can decrease the saturated inductance of the secondary windings of TTMS to a level less than 400 nH. As a result, the proposed TTMS can be used as the boosting transformer and main switch of helical Blumlein PFL to form the quasi-square voltage pulse on the 160 Ω load with a short pulse rise time only at 60 ns.

  6. Axial Magneto-Inductive Effect in Soft Magnetic Microfibers, Test Methodology, and Experiments

    Science.gov (United States)

    2016-03-24

    Nickle nT Nano- Tesla Si Silicon V Volts w Exchange Energy W Watts Zm Coil Impedance, measured  Circumferential Field Direction T Micro... Tesla  Ratio of Coil Length to Diameter  Ohm ° Degrees 1 (2 blank) 1. INTRODUCTION Magneto-induction (MI) effects in soft...axial magnetic field is utilized to excite the fiber. Previous investigators have demonstrated this effect with small coils applied directly to the

  7. The use of induction linacs with nonlinear magnetic drive as high average power accelerators

    International Nuclear Information System (INIS)

    Birx, D.L.; Cook, E.G.; Hawkins, S.A.; Newton, M.A.; Poor, S.E.; Reginato, L.L.; Schmidt, J.A.; Smith, M.W.

    1985-01-01

    The marriage of induction linac technology with Nonlinear Magnetic Modulators has produced some unique capabilities. It appears possible to produce electron beams with average currents measured in amperes, at gradients exceeding 1 MeV/m, and with power efficiences approaching 50%. A 2 MeV, 5 kA electron accelerator is under construction at Lawrence Livermore National Laboratory (LLNL) to allow us to demonstrate some of these concepts. Progress on this project is reported here. (orig.)

  8. Pulsed taut-wire measurement of the magnetic alignment of the ITS induction cells

    International Nuclear Information System (INIS)

    Melton, J.G.; Burns, M.J.; Honaberger, D.J.

    1993-01-01

    The mechanical and magnetic alignment of the first eight induction-cell, solenoid magnets of the Integrated Test Stand (ITS) for the Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility were measured by observing the deflection of a fine, taut wire carrying a pulsed current. To achieve the required alignment (less than 0.25 mm offset and less than 5 mrad tilt), the magnet design uses quadrufilar windings and iron field-smoothing rings. After detailed measurements of each solenoid magnet, the cells are assembled and then mechanically aligned using a laser and an alignment target moved along the cell centerline. After the cells are in final position, the pulsed wire method is used to verify the magnetic alignment. The measurements show an average offset of the magnetic axes from the mechanical axis of 0. 15 mm, with a maximum offset of 0.3 mm. The average tilt of the magnetic axis was 0.7 mrad with a maximum tilt of 1.4 mrad. Tilts are corrected to less than 0.3 mrad, using dipole trim magnets assembled into each cell. Correction is limited noise

  9. Non-chemotoxic induction of cancer cell death using magnetic nanowires

    Directory of Open Access Journals (Sweden)

    Contreras MF

    2015-03-01

    Full Text Available Maria F Contreras,1 Rachid Sougrat,2 Amir Zaher,3 Timothy Ravasi,1,3 Jürgen Kosel3 1Division of Biological and Environmental Sciences and Engineering, 2Advanced Nanofabrication Imaging and Characterization, 3Division of Computer, Electrical and Mathematical Sciences and Engineering, King Abdullah University of Science and Technology, Thuwal, Kingdom of Saudi Arabia Abstract: In this paper, we show that magnetic nanowires with weak magnetic fields and low frequencies can induce cell death via a mechanism that does not involve heat production. We incubated colon cancer cells with two concentrations (2.4 and 12 µg/mL of nickel nanowires that were 35 nm in diameter and exposed the cells and nanowires to an alternating magnetic field (0.5 mT and 1 Hz or 1 kHz for 10 or 30 minutes. This low-power field exerted a force on the magnetic nanowires, causing a mechanical disturbance to the cells. Transmission electron microscopy images showed that the nanostructures were internalized into the cells within 1 hour of incubation. Cell viability studies showed that the magnetic field and the nanowires separately had minor deleterious effects on the cells; however, when combined, the magnetic field and nanowires caused the cell viability values to drop by up to 39%, depending on the strength of the magnetic field and the concentration of the nanowires. Cell membrane leakage experiments indicated membrane leakage of 20%, suggesting that cell death mechanisms induced by the nanowires and magnetic field involve some cell membrane rupture. Results suggest that magnetic nanowires can kill cancer cells. The proposed process requires simple and low-cost equipment with exposure to only very weak magnetic fields for short time periods. Keywords: cell death induction, low frequency alternating magnetic field, nanomedicine, nanowire internalization, nickel nanowires

  10. Influence of different kinds of rolling on the crystallographic texture and magnetic induction of a NOG 3 wt% Si steel

    Science.gov (United States)

    Silva, J. M.; Baêta Júnior, E. S.; Moraes, N. R. D. C.; Botelho, R. A.; Felix, R. A. C.; Brandao, L.

    2017-01-01

    The purpose of this work was to study the influence of different kinds of rolling on the magnetic properties of NOG steel, an electric steel widely used in electrical motors. These properties are highly correlated with the crystallographic texture of the material, which can be changed by rolling. Three kinds of rolling were examined: conventional rolling, cross-rolling and asymmetrical rolling. The crystallographic texture was determined by X-ray diffraction and the magnetic properties were calculated from a theoretical model that related the magnetic induction to crystallographic texture through the anisotropy energy. The results show that cross-rolling yields higher values of magnetic induction than the other processes.

  11. The application of magnetic gradiometry and electromagnetic induction at a former radioactive waste disposal site.

    Science.gov (United States)

    Rucker, Dale Franklin

    2010-04-01

    A former radioactive waste disposal site is surveyed with two non-intrusive geophysical techniques, including magnetic gradiometry and electromagnetic induction. Data were gathered over the site by towing the geophysical equipment mounted to a non-electrically conductive and non-magnetic fibre-glass cart. Magnetic gradiometry, which detects the location of ferromagnetic material, including iron and steel, was used to map the existence of a previously unknown buried pipeline formerly used in the delivery of liquid waste to a number of surface disposal trenches and concrete vaults. The existence of a possible pipeline is reinforced by historical engineering drawing and photographs. The electromagnetic induction (EMI) technique was used to map areas of high and low electrical conductivity, which coincide with the magnetic gradiometry data. The EMI also provided information on areas of high electrical conductivity unrelated to a pipeline network. Both data sets demonstrate the usefulness of surface geophysical surveillance techniques to minimize the risk of exposure in the event of future remediation efforts.

  12. Effects of assistant anode on planar inductively coupled magnetized argon plasma in plasma immersion ion implantation

    International Nuclear Information System (INIS)

    Tang, Deli; Chu, Paul K.

    2003-01-01

    The enhancement of planar radio frequency (RF) inductively coupled argon plasma is studied in the presence of an assistant anode and an external magnetic field at low pressure. The influence of the assistant anode and magnetic field on the efficiency of RF power absorption and plasma parameters is investigated. An external axial magnetic field is coupled into the plasma discharge region by an external electromagnetic coil outside the discharge chamber and an assistant cylindrical anode is inserted into the discharge chamber to enhance the plasma discharge. The plasma parameters and density profile are measured by an electrostatic Langmuir probe at different magnetic fields and anode voltages. The RF power absorption by the plasma can be effectively enhanced by the external magnetic field compared with the nonmagnetized discharge. The plasma density can be further increased by the application of a voltage to the assistant anode. Owing to the effective power absorption and enhanced plasma discharge by the assistant anode in a longitudinal magnetic field, the plasma density can be enhanced by more than a factor of two. Meanwhile, the nonuniformity of the plasma density is less than 10% and it can be achieved in a process chamber with a diameter of 600 mm

  13. Influence of magnetic saturation effects on the fault detection of induction motors

    Directory of Open Access Journals (Sweden)

    Drozdowski Piotr

    2014-09-01

    Full Text Available In this paper, the influence of impact damage to the induction motors on the zero-sequence voltage and its spectrum is presented. The signals detecting the damages result from a detailed analysis of the formula describing this voltage component which is induced in the stator windings due to core magnetic saturation and the discrete displacement of windings. Its course is affected by the operation of both the stator and the rotor. Other fault detection methods, are known and widely applied by analysing the spectrum of stator currents. The presented method may be a complement to other methods because of the ease of measurements of the zero voltage for star connected motors. Additionally, for converter fed motors the zero sequence voltage eliminates higher time harmonics displaced by 120 degrees. The results of the method application are presented through measurements and explained by the use of a mathematical model of the slip-ring induction motor

  14. Magnetic induction of hyperthermia by a modified self-learning fuzzy temperature controller

    Science.gov (United States)

    Wang, Wei-Cheng; Tai, Cheng-Chi

    2017-07-01

    The aim of this study involved developing a temperature controller for magnetic induction hyperthermia (MIH). A closed-loop controller was applied to track a reference model to guarantee a desired temperature response. The MIH system generated an alternating magnetic field to heat a high magnetic permeability material. This wireless induction heating had few side effects when it was extensively applied to cancer treatment. The effects of hyperthermia strongly depend on the precise control of temperature. However, during the treatment process, the control performance is degraded due to severe perturbations and parameter variations. In this study, a modified self-learning fuzzy logic controller (SLFLC) with a gain tuning mechanism was implemented to obtain high control performance in a wide range of treatment situations. This implementation was performed by appropriately altering the output scaling factor of a fuzzy inverse model to adjust the control rules. In this study, the proposed SLFLC was compared to the classical self-tuning fuzzy logic controller and fuzzy model reference learning control. Additionally, the proposed SLFLC was verified by conducting in vitro experiments with porcine liver. The experimental results indicated that the proposed controller showed greater robustness and excellent adaptability with respect to the temperature control of the MIH system.

  15. The effect of receiver coil orientations on the imaging performance of magnetic induction tomography

    Science.gov (United States)

    Gürsoy, D.; Scharfetter, H.

    2009-10-01

    Magnetic induction tomography is an imaging modality which aims to reconstruct the conductivity distribution of the human body. It uses magnetic induction to excite the body and an array of sensor coils to detect the perturbations in the magnetic field. Up to now, much effort has been expended with the aim of finding an efficient coil configuration to extend the dynamic range of the measured signal. However, the merits of different sensor orientations on the imaging performance have not been studied in great detail so far. Therefore, the aim of the study is to fill the void of a systematic investigation of coil orientations on the reconstruction quality of the designs. To this end, a number of alternative receiver array designs with different coil orientations were suggested and the evaluations of the designs were performed based on the singular value decomposition. A generalized class of quality measures, the subclasses of which are linked to both the spatial resolution and uncertainty measures, was used to assess the performance on the radial and axial axes of a cylindrical phantom. The detectability of local conductivity perturbations in the phantom was explored using the reconstructed images. It is possible to draw the conclusion that the proper choice of the coil orientations significantly influences the number of usable singular vectors and accordingly the stability of image reconstruction, although the effect of increased stability on the quality of the reconstructed images was not of paramount importance due to the reduced independent information content of the associated singular vectors.

  16. The effect of receiver coil orientations on the imaging performance of magnetic induction tomography

    International Nuclear Information System (INIS)

    Gürsoy, D; Scharfetter, H

    2009-01-01

    Magnetic induction tomography is an imaging modality which aims to reconstruct the conductivity distribution of the human body. It uses magnetic induction to excite the body and an array of sensor coils to detect the perturbations in the magnetic field. Up to now, much effort has been expended with the aim of finding an efficient coil configuration to extend the dynamic range of the measured signal. However, the merits of different sensor orientations on the imaging performance have not been studied in great detail so far. Therefore, the aim of the study is to fill the void of a systematic investigation of coil orientations on the reconstruction quality of the designs. To this end, a number of alternative receiver array designs with different coil orientations were suggested and the evaluations of the designs were performed based on the singular value decomposition. A generalized class of quality measures, the subclasses of which are linked to both the spatial resolution and uncertainty measures, was used to assess the performance on the radial and axial axes of a cylindrical phantom. The detectability of local conductivity perturbations in the phantom was explored using the reconstructed images. It is possible to draw the conclusion that the proper choice of the coil orientations significantly influences the number of usable singular vectors and accordingly the stability of image reconstruction, although the effect of increased stability on the quality of the reconstructed images was not of paramount importance due to the reduced independent information content of the associated singular vectors

  17. Snubber-less NPC inverter by a novel reduction technique of parasitic inductance for magnet power supplies

    Energy Technology Data Exchange (ETDEWEB)

    Koseki, K., E-mail: kunio.koseki@kek.jp; Morita, Y.

    2014-10-11

    The effects induced by parasitic inductance were studied in a neutral point clamped (NPC) inverter. The energy stored in the parasitic inductance by the output current causes a surge voltage during the turn-off period of semiconductor switches. The effect is serious in a magnet power supply for which a large excitation current is required. It is predicted by a circuit analysis that the parasitic inductance causes an electrical breakdown of the semiconductor switches. It was found that the most promising way to mitigate the effect is to reduce the parasitic inductance. With newly developed circuitry and layout of an NPC inverter, cancelation of the induced magnetic field, which is based on Ampere's circuital law, in power devices has been accomplished. The newly developed NPC inverter has been operated successfully with both a resistive dummy load and the dipole magnets in the main ring synchrotron at the J-PARC facility.

  18. Borehole logging

    International Nuclear Information System (INIS)

    Olsen, H.

    1995-01-01

    Numerous ground water investigations have been accomplished by means of borehole logging. Borehole logging can be applied to establish new water recovery wells, to control the existing water producing wells and source areas and to estimate ground water quality. (EG)

  19. Improvements in the measurement system of a biological Magnetic Induction Tomographical experimental setup

    International Nuclear Information System (INIS)

    Bras, N. B.; Martins, R. C.; Serra, A. C.

    2010-01-01

    Magnetic Induction Tomography (MIT) is an imaging technique that allows mapping the internal structure complex conductivity of a body. In this paper a feasibility study to implement a higher resolution MIT system for biological tissues is carried out. Recent improvements in measured signal stability and accuracy as well as a much improved angular resolution measurement of the multi-coil setup are presented which, together with a new mechanical design allows obtaining longer stable and more accurate acquisitions. This allows improving the number of measurements without trends or external perturbations, leading to a better conductivity resolution and to an enhanced image reconstruction. Throughout the paper experimental data is used to consolidate results.

  20. The Numerical Calculation and Experimental Measurement of the Inductance Parameters for Permanent Magnet Synchronous Motor in Electric Vehicle

    Science.gov (United States)

    Jiang, Chao; Qiao, Mingzhong; Zhu, Peng

    2017-12-01

    A permanent magnet synchronous motor with radial magnetic circuit and built-in permanent magnet is designed for the electric vehicle. Finite element numerical calculation and experimental measurement are adopted to obtain the direct axis and quadrature axis inductance parameters of the motor which are vital important for the motor control. The calculation method is simple, the measuring principle is clear, the results of numerical calculation and experimental measurement are mutual confirmation. A quick and effective method is provided to obtain the direct axis and quadrature axis inductance parameters of the motor, and then improve the design of motor or adjust the control parameters of the motor controller.

  1. Analytical Calculation of D- and Q-axis Inductance for Interior Permanent Magnet Motors Based on Winding Function Theory

    Directory of Open Access Journals (Sweden)

    Peixin Liang

    2016-07-01

    Full Text Available Interior permanent magnet (IPM motors are widely used in electric vehicles (EVs, benefiting from the excellent advantages of a more rational use of energy. For further improvement of energy utilization, this paper presents an analytical method of d- and q-axis inductance calculation for IPM motors with V-shaped rotor in no-load condition. A lumped parameter magnetic circuit model (LPMCM is adopted to investigate the saturation and nonlinearity of the bridge. Taking into account the influence of magnetic field distribution on inductance, the winding function theory (WFT is employed to accurately calculate the armature reaction airgap magnetic field and d- and q-axis inductances. The validity of the analytical technique is verified by the finite element method (FEM.

  2. Magnetic field alignment for a 20 MeV linear induction accelerator

    International Nuclear Information System (INIS)

    Zhang Wenwei; Pan Haifeng; Li Hong; Liu Yunlong; Zhang Linwen

    2002-01-01

    'Dragon-1' accelerator now is being constructed in CAEP. It will produce high current pulse electron beams. The main components of the accelerator include 72 induction accelerating cells and 18 connection cells with ports for beam di gnostic hardware and vacuum pump. In order to acquire high quality beams, a lot of problems have to be addressed such as to reduce the emittance, to control the increase of corkscrew and so on. The alignment of the focus magnetic field is the most concerned. A laser track has been used for mechanical alignment, magnetic alignment is performed by using pulsed-wire technique, and the natural tilt errors is corrected by a pair of steering coil, which is located inside the cell

  3. Prototyping Energy Efficient Thermo-Magnetic & Induction Hardening for Heat Treat & Net Shape Forming Applications

    Energy Technology Data Exchange (ETDEWEB)

    Aquil Ahmad

    2012-08-03

    Within this project, Eaton undertook the task of bringing about significant impact with respect to sustainability. One of the major goals for the Department of Energy is to achieve energy savings with a corresponding reduction in carbon foot print. The use of a coupled induction heat treatment with high magnetic field heat treatment makes possible not only improved performance alloys, but with faster processing times and lower processing energy, as well. With this technology, substitution of lower cost alloys for more exotic alloys became a possibility; microstructure could be tailored for improved magnetic properties or wear resistance or mechanical performance, as needed. A prototype commercial unit has been developed to conduct processing of materials. Testing of this equipment has been conducted and results demonstrate the feasibility for industrial commercialization.

  4. Problem of simulating the Earth's induction effects in modeling polar magnetic substorms

    International Nuclear Information System (INIS)

    Mareschal, M.

    1976-01-01

    A major problem encountered in trying to model the current system associated with a polar magnetic substorm from ground-based magnetic observations is the difficulty of adequately evaluating the earth's induction effects. Two methods for simulating these effects are reviewed here. Method 1 simply reduces the earth to a perfect conductor and leads to very simple field equations. Method 2 considers the earth as a ''horizontally'' layered body of finite conductivity but requires a large amount of computational time. The performances of both methods are compared when the substorm current system can be approximated by an infinitely long electrojet flowing over a flat earth. In this case it appears that for most substorm modeling problems it is sufficient to treat the earth as a perfect conductor. The depth of this perfect conductor below the earth's surface should be selected in function of the source frequency content

  5. Inductively Coupled Plasma: Fundamental Particle Investigations with Laser Ablation and Applications in Magnetic Sector Mass Spectrometry

    International Nuclear Information System (INIS)

    Nathan Joe Saetveit

    2008-01-01

    Particle size effects and elemental fractionation in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) are investigated with nanosecond and femtosecond laser ablation, differential mobility analysis, and magnetic sector ICP-MS. Laser pulse width was found to have a significant influence on the LA particle size distribution and the elemental composition of the aerosol and thus fractionation. Emission from individual particles from solution nebulization, glass, and a pressed powder pellet are observed with high speed digital photography. The presence of intact particles in an ICP is shown to be a likely source of fractionation. A technique for the online detection of stimulated elemental release from neural tissue using magnetic sector ICP-MS is described. Detection limits of 1 (micro)g L -1 or better were found for P, Mn, Fe, Cu, and Zn in a 60 (micro)L injection in a physiological saline matrix

  6. Induction of biogenic magnetization and redox control by a component of the target of rapamycin complex 1 signaling pathway.

    Directory of Open Access Journals (Sweden)

    Keiji Nishida

    Full Text Available Most organisms are simply diamagnetic, while magnetotactic bacteria and migratory animals are among organisms that exploit magnetism. Biogenic magnetization not only is of fundamental interest, but also has industrial potential. However, the key factor(s that enable biogenic magnetization in coordination with other cellular functions and metabolism remain unknown. To address the requirements for induction and the application of synthetic bio-magnetism, we explored the creation of magnetism in a simple model organism. Cell magnetization was first observed by attraction towards a magnet when normally diamagnetic yeast Saccharomyces cerevisiae were grown with ferric citrate. The magnetization was further enhanced by genetic modification of iron homeostasis and introduction of ferritin. The acquired magnetizable properties enabled the cells to be attracted to a magnet, and be trapped by a magnetic column. Superconducting quantum interference device (SQUID magnetometry confirmed and quantitatively characterized the acquired paramagnetism. Electron microscopy and energy-dispersive X-ray spectroscopy showed electron-dense iron-containing aggregates within the magnetized cells. Magnetization-based screening of gene knockouts identified Tco89p, a component of TORC1 (Target of rapamycin complex 1, as important for magnetization; loss of TCO89 and treatment with rapamycin reduced magnetization in a TCO89-dependent manner. The TCO89 expression level positively correlated with magnetization, enabling inducible magnetization. Several carbon metabolism genes were also shown to affect magnetization. Redox mediators indicated that TCO89 alters the intracellular redox to an oxidized state in a dose-dependent manner. Taken together, we demonstrated that synthetic induction of magnetization is possible and that the key factors are local redox control through carbon metabolism and iron supply.

  7. Tucker Wireline Open Hole Wireline Logging; FINAL

    International Nuclear Information System (INIS)

    Milliken, M.

    2002-01-01

    The Tucker Wireline unit ran a suite of open hole logs right behind the RMOTC logging contractor for comparison purposes. The tools included Dual Laterolog, Phased Induction, BHC Sonic, and Density-Porosity

  8. Inductive Displacement Sensors with a Notch Filter for an Active Magnetic Bearing System

    Directory of Open Access Journals (Sweden)

    Seng-Chi Chen

    2014-07-01

    Full Text Available Active magnetic bearing (AMB systems support rotating shafts without any physical contact, using electromagnetic forces. Each radial AMB uses two pairs of electromagnets at opposite sides of the rotor. This allows the rotor to float in the air gap, and the machine to operate without frictional losses. In active magnetic suspension, displacement sensors are necessary to detect the radial and axial movement of the suspended object. In a high-speed rotating machine equipped with an AMB, the rotor bending modes may be limited to the operating range. The natural frequencies of the rotor can cause instability. Thus, notch filters are a useful circuit for stabilizing the system. In addition, commercial displacement sensors are sometimes not suitable for AMB design, and cannot filter the noise caused by the natural frequencies of rotor. Hence, implementing displacement sensors based on the AMB structure is necessary to eliminate noises caused by natural frequency disturbances. The displacement sensor must be highly sensitive in the desired working range, and also exhibit a low interference noise, high stability, and low cost. In this study, we used the differential inductive sensor head and lock-in amplifier for synchronous demodulation. In addition, an active low-pass filter and a notch filter were used to eliminate disturbances, which caused by natural frequencies. As a consequence, the inductive displacement sensor achieved satisfactory linearity, high sensitivity, and disturbance elimination. This sensor can be easily produced for AMB applications. A prototype of these displacement sensors was built and tested.

  9. Mapping of Students’ Learning Progression Based on Mental Model in Magnetic Induction Concepts

    Science.gov (United States)

    Hamid, R.; Pabunga, D. B.

    2017-09-01

    The progress of student learning in a learning process has not been fully optimally observed by the teacher. The concept being taught is judged only at the end of learning as a product of thinking, and does not assess the mental processes that occur in students’ thinking. Facilitating students’ thinking through new phenomena can reveal students’ variation in thinking as a mental model of a concept, so that students who are assimilative and or accommodative can be identified in achieving their equilibrium of thought as well as an indicator of progressiveness in the students’ thinking stages. This research data is obtained from the written documents and interviews of students who were learned about the concept of magnetic induction through Constructivist Teaching Sequences (CTS) models. The results of this study indicate that facilitating the students’ thinking processes on the concept of magnetic induction contributes to increasing the number of students thinking within the "progressive change" category, and it can be said that the progress of student learning is more progressive after their mental models were facilitated through a new phenomena by teacher.

  10. Inductive displacement sensors with a notch filter for an active magnetic bearing system.

    Science.gov (United States)

    Chen, Seng-Chi; Le, Dinh-Kha; Nguyen, Van-Sum

    2014-07-15

    Active magnetic bearing (AMB) systems support rotating shafts without any physical contact, using electromagnetic forces. Each radial AMB uses two pairs of electromagnets at opposite sides of the rotor. This allows the rotor to float in the air gap, and the machine to operate without frictional losses. In active magnetic suspension, displacement sensors are necessary to detect the radial and axial movement of the suspended object. In a high-speed rotating machine equipped with an AMB, the rotor bending modes may be limited to the operating range. The natural frequencies of the rotor can cause instability. Thus, notch filters are a useful circuit for stabilizing the system. In addition, commercial displacement sensors are sometimes not suitable for AMB design, and cannot filter the noise caused by the natural frequencies of rotor. Hence, implementing displacement sensors based on the AMB structure is necessary to eliminate noises caused by natural frequency disturbances. The displacement sensor must be highly sensitive in the desired working range, and also exhibit a low interference noise, high stability, and low cost. In this study, we used the differential inductive sensor head and lock-in amplifier for synchronous demodulation. In addition, an active low-pass filter and a notch filter were used to eliminate disturbances, which caused by natural frequencies. As a consequence, the inductive displacement sensor achieved satisfactory linearity, high sensitivity, and disturbance elimination. This sensor can be easily produced for AMB applications. A prototype of these displacement sensors was built and tested.

  11. Characteristic Of Induction Magnetic Field On The Laboratory Scale Superconducting Fault Current Limiter Circuit

    International Nuclear Information System (INIS)

    Adi, Wisnu Ari; Sukirman, E.; Didin, S.W.; Yustinus, P.M.; Siregar, Riswal H.

    2004-01-01

    Model construction of the laboratory scale superconducting fault current limiter circuit (SFCL) has been performed. The SFCL is fault current limiter and used as electric network security. It mainly consists of a copper coil, a superconducting ring and an iron core that are concentrically arranged. The SFCL circuit is essentially a transformer where the secondary windings are being replaced by the ring of YBa 2 Cu 3 O 7-x superconductor (HTS). The ring has critical transition temperature Tc = 92 K and critical current Ic = 3.61 A. Characterization of the SFCL circuit is simulated by ANSYS version 5.4 software. The SFCL circuit consists of load and transformer impedances. The results show that the inductions of magnet field flux in the iron core of primer windings and ring disappear to one other before fault state. It means that impedance of the transformer is zero. After the condition a superconductivity behavior of the ring is disappear so that the impedance of the transformer becomes very high. From this experiment, we concluded that the SFCL circuit could work normally if the resultant of induction magnetic in the iron core (transformer) is zero

  12. Increasing the magnetic-field capability of the magneto-inertial fusion electrical discharge system using an inductively coupled coil

    Science.gov (United States)

    Barnak, D. H.; Davies, J. R.; Fiksel, G.; Chang, P.-Y.; Zabir, E.; Betti, R.

    2018-03-01

    Magnetized high energy density physics (HEDP) is a very active and relatively unexplored field that has applications in inertial confinement fusion, astrophysical plasma science, and basic plasma physics. A self-contained device, the Magneto-Inertial Fusion Electrical Discharge System, MIFEDS [G. Fiksel et al., Rev. Sci. Instrum. 86, 016105 (2015)], was developed at the Laboratory for Laser Energetics to conduct magnetized HEDP experiments on both the OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495-506 (1997)] and OMEGA EP [J. H. Kelly et al., J. Phys. IV France 133, 75 (2006) and L. J. Waxer et al., Opt. Photonics News 16, 30 (2005)] laser systems. Extremely high magnetic fields are a necessity for magnetized HEDP, and the need for stronger magnetic fields continues to drive the redevelopment of the MIFEDS device. It is proposed in this paper that a magnetic coil that is inductively coupled rather than directly connecting to the MIFEDS device can increase the overall strength of the magnetic field for HEDP experiments by increasing the efficiency of energy transfer while decreasing the effective magnetized volume. A brief explanation of the energy delivery of the MIFEDS device illustrates the benefit of inductive coupling and is compared to that of direct connection for varying coil size and geometry. A prototype was then constructed to demonstrate a 7-fold increase in energy delivery using inductive coupling.

  13. Detection of cerebral hemorrhage in rabbits by time-difference magnetic inductive phase shift spectroscopy.

    Directory of Open Access Journals (Sweden)

    Wencai Pan

    Full Text Available Cerebral hemorrhage, a difficult issue in clinical practice, is often detected and studied with computed tomography (CT, magnetic resonance imaging (MRI, and positron emission tomography (PET. However, these expensive devices are not readily available in economically underdeveloped regions, and hence are unable to provide bedside and emergency on-site monitoring. The magnetic inductive phase shift (MIPS is an emerging technology that may become a new tool to detect cerebral hemorrhage and to serve as an inexpensive partial substitute to medical imaging. In order to study a wider band of cerebral hemorrhage MIPS and to provide more useful information for measuring cerebral hemorrhage, we established a cerebral hemorrhage magnetic induction phase shift spectroscopy (MIPSS detection system. Thirteen rabbits with five cerebral hemorrhage states were studied using a single coil-coil within a 1 MHz-200 MHz frequency range in linear sweep. A feature band (FB with the highest detection sensitivity and the greatest stability was selected for further analysis and processing. In addition, a maximum conductivity cerebrospinal fluid (CSF MRI was performed to verify and interpret the MIPSS result. The average phase shift change induced by a 3 ml injection of autologous blood under FB was -7.7503° ± 1.4204°, which was considerably larger than our previous work. Data analysis with a non-parametric statistical Friedman M test showed that in the FB, MIPSS could distinguish the five states of cerebral hemorrhage in rabbits, with a statistical significance of p<0.05. A B-F distribution profile was designed according to the MIPSS under FB that can provide instantaneous diagnostic information about the cerebral hemorrhage severity from a single set of measurements. The results illustrate that the MIPSS detection method is able to provide a new possibility for real-time monitoring and diagnosis of the severity of cerebral hemorrhage.

  14. Detection of Cerebral Hemorrhage in Rabbits by Time-Difference Magnetic Inductive Phase Shift Spectroscopy

    Science.gov (United States)

    Pan, Wencai; Yan, Qingguang; Qin, Mingxin; Jin, Gui; Sun, Jian; Ning, Xu; Zhuang, Wei; Peng, Bin; Li, Gen

    2015-01-01

    Cerebral hemorrhage, a difficult issue in clinical practice, is often detected and studied with computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET). However, these expensive devices are not readily available in economically underdeveloped regions, and hence are unable to provide bedside and emergency on-site monitoring. The magnetic inductive phase shift (MIPS) is an emerging technology that may become a new tool to detect cerebral hemorrhage and to serve as an inexpensive partial substitute to medical imaging. In order to study a wider band of cerebral hemorrhage MIPS and to provide more useful information for measuring cerebral hemorrhage, we established a cerebral hemorrhage magnetic induction phase shift spectroscopy (MIPSS) detection system. Thirteen rabbits with five cerebral hemorrhage states were studied using a single coil-coil within a 1 MHz-200 MHz frequency range in linear sweep. A feature band (FB) with the highest detection sensitivity and the greatest stability was selected for further analysis and processing. In addition, a maximum conductivity cerebrospinal fluid (CSF) MRI was performed to verify and interpret the MIPSS result. The average phase shift change induced by a 3 ml injection of autologous blood under FB was -7.7503° ± 1.4204°, which was considerably larger than our previous work. Data analysis with a non-parametric statistical Friedman M test showed that in the FB, MIPSS could distinguish the five states of cerebral hemorrhage in rabbits, with a statistical significance of phemorrhage severity from a single set of measurements. The results illustrate that the MIPSS detection method is able to provide a new possibility for real-time monitoring and diagnosis of the severity of cerebral hemorrhage. PMID:26001112

  15. Determination of High-Frequency d- and q-axis Inductances for Surface-Mounted Permanent-Magnet Synchronous Machines

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Vetuschi, M.; Rasmussen, Peter Omand

    2010-01-01

    This paper presents a reliable method for the experimental determination of high-frequency d- and q -axis inductances for surface-mounted permanent-magnet synchronous machines (SMPMSMs). Knowledge of the high-frequency d- and q-axis inductances plays an important role in the efficient design...... of sensorless controllers using high-frequency signal injection techniques. The proposed method employs a static locked-rotor test using an ac +dc power supply. By injecting a high-frequency rotating voltage vector into the machine, the d- and q-axis inductances may simultaneously be determined with no need...

  16. Self-consistent simulation study on magnetized inductively coupled plasma for 450 mm semiconductor wafer processing

    International Nuclear Information System (INIS)

    Lee, Ho-Jun; Kim, Yun-Gi

    2012-01-01

    The characteristics of weakly magnetized inductively coupled plasma (MICP) are investigated using a self-consistent simulation based on the drift–diffusion approximation with anisotropic transport coefficients. MICP is a plasma source utilizing the cavity mode of the low-frequency branch of the right-hand circularly polarized wave. The model system is 700 mm in diameter and has a 250 mm gap between the radio-frequency window and wafer holder. The model chamber size is chosen to verify the applicability of this type of plasma source to the 450 mm wafer process. The effects of electron density distribution and external axial magnetic field on the propagation properties of the plasma wave, including the wavelength modulation and refraction toward the high-density region, are demonstrated. The restricted electron transport and thermal conductivity in the radial direction due to the magnetic field result in small temperature gradient along the field lines and off-axis peak density profile. The calculated impedance seen from the antenna terminal shows that MICP has a resistance component that is two to threefold higher than that of ICP. This property is practically important for large-size, low-pressure plasma sources because high resistance corresponds to high power-transfer efficiency and stable impedance matching characteristics. For the 0.665 Pa argon plasma, MICP shows a radial density uniformity of 6% within 450 mm diameter, which is much better than that of nonmagnetized ICP.

  17. Functionalized magnetic nanowires for chemical and magneto-mechanical induction of cancer cell death

    KAUST Repository

    Martinez Banderas, Aldo Isaac

    2016-10-24

    Exploiting and combining different properties of nanomaterials is considered a potential route for next generation cancer therapies. Magnetic nanowires (NWs) have shown good biocompatibility and a high level of cellular internalization. We induced cancer cell death by combining the chemotherapeutic effect of doxorubicin (DOX)-functionalized iron NWs with the mechanical disturbance under a low frequency alternating magnetic field. (3-aminopropyl)triethoxysilane (APTES) and bovine serum albumin (BSA) were separately used for coating NWs allowing further functionalization with DOX. Internalization was assessed for both formulations by confocal reflection microscopy and inductively coupled plasma-mass spectrometry. From confocal analysis, BSA formulations demonstrated higher internalization and less agglomeration. The functionalized NWs generated a comparable cytotoxic effect in breast cancer cells in a DOX concentration-dependent manner, (~60% at the highest concentration tested) that was significantly different from the effect produced by free DOX and non-functionalized NWs formulations. A synergistic cytotoxic effect is obtained when a magnetic field (1 mT, 10 Hz) is applied to cells treated with DOX-functionalized BSA or APTES-coated NWs, (~70% at the highest concentration). In summary, a bimodal method for cancer cell destruction was developed by the conjugation of the magneto-mechanical properties of iron NWs with the effect of DOX producing better results than the individual effects.

  18. Functionalized magnetic nanowires for chemical and magneto-mechanical induction of cancer cell death

    KAUST Repository

    Martinez Banderas, Aldo; Aires, Antonio; Teran, Francisco J.; Perez, Jose E.; Cadenas, Jael F.; Alsharif, Nouf; Ravasi, Timothy; Cortajarena, Aitziber L.; Kosel, Jü rgen

    2016-01-01

    Exploiting and combining different properties of nanomaterials is considered a potential route for next generation cancer therapies. Magnetic nanowires (NWs) have shown good biocompatibility and a high level of cellular internalization. We induced cancer cell death by combining the chemotherapeutic effect of doxorubicin (DOX)-functionalized iron NWs with the mechanical disturbance under a low frequency alternating magnetic field. (3-aminopropyl)triethoxysilane (APTES) and bovine serum albumin (BSA) were separately used for coating NWs allowing further functionalization with DOX. Internalization was assessed for both formulations by confocal reflection microscopy and inductively coupled plasma-mass spectrometry. From confocal analysis, BSA formulations demonstrated higher internalization and less agglomeration. The functionalized NWs generated a comparable cytotoxic effect in breast cancer cells in a DOX concentration-dependent manner, (~60% at the highest concentration tested) that was significantly different from the effect produced by free DOX and non-functionalized NWs formulations. A synergistic cytotoxic effect is obtained when a magnetic field (1 mT, 10 Hz) is applied to cells treated with DOX-functionalized BSA or APTES-coated NWs, (~70% at the highest concentration). In summary, a bimodal method for cancer cell destruction was developed by the conjugation of the magneto-mechanical properties of iron NWs with the effect of DOX producing better results than the individual effects.

  19. Functionalized magnetic nanowires for chemical and magneto-mechanical induction of cancer cell death.

    Science.gov (United States)

    Martínez-Banderas, Aldo Isaac; Aires, Antonio; Teran, Francisco J; Perez, Jose Efrain; Cadenas, Jael F; Alsharif, Nouf; Ravasi, Timothy; Cortajarena, Aitziber L; Kosel, Jürgen

    2016-10-24

    Exploiting and combining different properties of nanomaterials is considered a potential route for next generation cancer therapies. Magnetic nanowires (NWs) have shown good biocompatibility and a high level of cellular internalization. We induced cancer cell death by combining the chemotherapeutic effect of doxorubicin (DOX)-functionalized iron NWs with the mechanical disturbance under a low frequency alternating magnetic field. (3-aminopropyl)triethoxysilane (APTES) and bovine serum albumin (BSA) were separately used for coating NWs allowing further functionalization with DOX. Internalization was assessed for both formulations by confocal reflection microscopy and inductively coupled plasma-mass spectrometry. From confocal analysis, BSA formulations demonstrated higher internalization and less agglomeration. The functionalized NWs generated a comparable cytotoxic effect in breast cancer cells in a DOX concentration-dependent manner, (~60% at the highest concentration tested) that was significantly different from the effect produced by free DOX and non-functionalized NWs formulations. A synergistic cytotoxic effect is obtained when a magnetic field (1 mT, 10 Hz) is applied to cells treated with DOX-functionalized BSA or APTES-coated NWs, (~70% at the highest concentration). In summary, a bimodal method for cancer cell destruction was developed by the conjugation of the magneto-mechanical properties of iron NWs with the effect of DOX producing better results than the individual effects.

  20. Inductive Sustainment of Oblate FRCs with the Assistance of Magnetic Diffusion, Shaping and Finite-Lamor Radius Stabilization

    International Nuclear Information System (INIS)

    Gerhardt, S.; Belova, E.V.; Yamada, M.; Ji, H.; Inomoto, M.; Jacobson, C.M.; Maqueda, R.; McGeehan, B.; Ren, Y.

    2008-01-01

    Oblate field-reversed configurations FRCs have been sustained for >300 (micro)s, or >15 magnetic diffusion times, through the use of an inductive solenoid. These argon FRCs can have their poloidal flux sustained or increased, depending on the timing and strength of the induction. An inward pinch is observed during sustainment, leading to a peaking of the pressure profile and maintenance of the FRC equilibrium. The good stability observed in argon (and krypton) does not transfer to lighter gases, which develop terminal co-interchange instabilities. The stability in argon and krypton is attributed to a combination of external field shaping, magnetic diffusion, and finite-Larmor radius effects.

  1. Mechanics of log calibration

    International Nuclear Information System (INIS)

    Waller, W.C.; Cram, M.E.; Hall, J.E.

    1975-01-01

    For any measurement to have meaning, it must be related to generally accepted standard units by a valid and specified system of comparison. To calibrate well-logging tools, sensing systems are designed which produce consistent and repeatable indications over the range for which the tool was intended. The basics of calibration theory, procedures, and calibration record presentations are reviewed. Calibrations for induction, electrical, radioactivity, and sonic logging tools will be discussed. The authors' intent is to provide an understanding of the sources of errors, of the way errors are minimized in the calibration process, and of the significance of changes in recorded calibration data

  2. Numerical modeling and design of a disk-type rotating permanent magnet induction pump

    Energy Technology Data Exchange (ETDEWEB)

    Koroteeva, E., E-mail: koroteeva@physics.msu.ru [Institute of Physics of University of Latvia, Salaspils 2169 (Latvia); Lomonosov Moscow State University, Moscow 119991 (Russian Federation); Ščepanskis, M. [Laboratory for Mathematical Modelling of Environmental and Technological Processes, University of Latvia, Rīga 1002 (Latvia); Bucenieks, I.; Platacis, E. [Institute of Physics of University of Latvia, Salaspils 2169 (Latvia)

    2016-05-15

    Highlights: • The design and performance of a disk-type induction pump are described. • A 3D numerical model based on an iterative coupling between EM and hydrodynamic solvers is developed. • The model is verified by comparing with the experiments in a Pb-Bi loop facility. • The suggestions are given to estimate the pump performance in a Pb-Li loop at high pressures. - Abstract: Electromagnetic induction pumps with rotating permanent magnets appear to be the most promising devices to transport liquid metals in high-temperature applications. Here we present a numerical methodology to simulate the operation of one particular modification of these types of pumps: a disk-type induction pump. The numerical model allows for the calculation and analysis of the flow parameters, including the pressure–flow rate characteristics of the pump. The simulations are based on an iterative fully coupled scheme for electromagnetic and hydrodynamic solvers. The developed model is verified by comparing with experimental data obtained using a Pb-Bi loop test facility, for pressures up to 4 bar and flow rates up to 9 kg/s. The verified model is then expanded to higher pressures, beyond the limits of the experimental loop. Based on the numerical simulations, suggestions are given to extrapolate experimental data to higher (industrially important) pressure ranges. Using the numerical model and analytical estimation, the pump performance for the Pb-Li loop is also examined, and the ability of the designed pump to develop pressure heads over 6 bar and to provide flow rates over 15 kg/s is shown.

  3. Non-Contact Monitoring of Heart and Lung Activity by Magnetic Induction Measurement

    Directory of Open Access Journals (Sweden)

    M. Steffen

    2008-01-01

    Full Text Available In many clinical applications, the monitoring of heart and lung activity is of vital importance. State-of-the-art monitoring involves the use of electrodes or other contact based sensors (electrocardiogram (ECG, impedance cardiography (ICG, pulse oximetry or equivalent. With the equipment that is used, side effects like skin irritation, difficult application or additional cabling may occur. In contrast, this paper describes a method for non-contact monitoring of heart and lung activity, which is solely based on magnetic induction. This method allows simultaneous monitoring of heart and lung activity, and has the potential of an integrated application in a personal healthcare scenario. To illustrate the performance, a simple test-setup has been developed and the first results are presented here (some of which have been previously presented on the Poster 2008 [10]. 

  4. 87Sr/86Sr dating and preliminary interpretation of magnetic susceptibility logs of giant piston cores from the Rio Grande Rise in the South Atlantic

    Science.gov (United States)

    Lacasse, Christian Michel; Santos, Roberto Ventura; Dantas, Elton Luiz; Vigneron, Quentin; de Sousa, Isabela Moreno Cordeiro; Harlamov, Vadim; Lisniowski, Maria Aline; Pessanha, Ivo Bruno Machado; Frazão, Eugênio Pires; Cavalcanti, José Adilson Dias

    2017-12-01

    Giant piston cores recovered from shallow depths (optimized matching with an internationally recognized timescale of 87Sr/86Sr seawater variation through geological times. Depth-to-age conversion of the magnetic susceptibility logs was implemented based on the identification of correlative peaks between cores and the developed 87Sr/86Sr age model. The influence of Northern Hemisphere glaciation is reflected in these new stratigraphic logs by a gradual increase from ∼2.7 Ma in the lower signal of magnetic susceptibility (below background level), to values approaching the arithmetic means, likely reflecting an overall increase in terrigenous input. The Rio Grande Rise cores have very low Plio-Pleistocene sedimentation rates (∼0.4-0.8 cm/ka), similar to gravity cores from the oligotrophic subtropical South Atlantic (below ∼2000 mbsl), and for which an inverse correlation between carbonate content and magnetic susceptibility was established. The coring depths on the Rio Grande Rise encompass strong gradients in oxygen concentration and other seawater parameters that define today's AAIW/UCDW transition. Depth-dependent variation in sedimentation rates since the onset of Northern Hemisphere glaciation coincides with the incursion of intermediate waters (UCDW, AAIW) in response to the overall reduction of NADW export to the Southern Ocean. Background levels of magnetic susceptibility in the cores suggest that this variation is mainly attributed to terrigenous input. The source region of this material has yet to be traced by considering in particular the mineral composition and paramagnetic properties of the detrital clays.

  5. A novel approach to calculate inductance and analyze magnetic flux density of helical toroidal coil applicable to Superconducting Magnetic Energy Storage systems (SMES)

    International Nuclear Information System (INIS)

    Alizadeh Pahlavani, M.R.; Shoulaie, A.

    2010-01-01

    In this paper, formulas are proposed for the self and mutual inductance calculations of the helical toroidal coil (HTC) by the direct and indirect methods at superconductivity conditions. The direct method is based on the Neumann's equation and the indirect approach is based on the toroidal and the poloidal components of the magnetic flux density. Numerical calculations show that the direct method is more accurate than the indirect approach at the expense of its longer computational time. Implementation of some engineering assumptions in the indirect method is shown to reduce the computational time without loss of accuracy. Comparison between the experimental measurements and simulated results for inductance, using the direct and the indirect methods indicates that the proposed formulas have high reliability. It is also shown that the self inductance and the mutual inductance could be calculated in the same way, provided that the radius of curvature is >0.4 of the minor radius, and that the definition of the geometric mean radius in the superconductivity conditions is used. Plotting contours for the magnetic flux density and the inductance show that the inductance formulas of helical toroidal coil could be used as the basis for coil optimal design. Optimization target functions such as maximization of the ratio of stored magnetic energy with respect to the volume of the toroid or the conductor's mass, the elimination or the balance of stress in some coordinate directions, and the attenuation of leakage flux could be considered. The finite element (FE) approach is employed to present an algorithm to study the three-dimensional leakage flux distribution pattern of the coil and to draw the magnetic flux density lines of the HTC. The presented algorithm, due to its simplicity in analysis and ease of implementation of the non-symmetrical and three-dimensional objects, is advantageous to the commercial software such as ANSYS, MAXWELL, and FLUX. Finally, using the

  6. ANALYSIS OF THE SPECIAL FEATURES OF THE THERMAL PROCESS IN AN INDUCTION GENERATOR AT HIGH SATURATION OF THE MAGNETIC SYSTEM

    Directory of Open Access Journals (Sweden)

    V. Chenchevoi

    2017-06-01

    Full Text Available Purpose. Development of the method for the assessment of the thermal operation modes of an autonomous electrical power system with an induction motor, aiming at improvement of the reliability of electricity supply and the quality of electric energy. Methodology. Induction generator mathematical modeling taking into account the magnetic system saturation was used in the research. A heat model taking into account the excess of the temperature of the induction generator units in the mode of high saturation was developed. The obtained results were compared with the experimental data. Results. The paper contains the solution to the problem of improvement of the mathematical model sand methods for steel losses determination in there search of the operation modes of an autonomous uncontrolled induction generator taking into consideration the properties of the magnetic system in the mode of high saturation. The expression for determination of steel losses in the mode of high saturation is obtained. It enables the assessment of the induction generator thermal condition. Originality. The analytical dependence for the calculation of the steel losses in the mode of magnetic system saturation has been obtained for the first time. Practical value. The obtained expression for the calculation of the steel losses can be used for determination of the admissible time of generator operation at overload. It will allow avoiding broken winding insulation and complete use of the generator overload capacity. As a result, it will reduce possible irregularities of electricity supply due to the generator preliminary cutoff.

  7. Apparatus and method for reducing inductive coupling between levitation and drive coils within a magnetic propulsion system

    Science.gov (United States)

    Post, Richard F.

    2001-01-01

    An apparatus and method is disclosed for reducing inductive coupling between levitation and drive coils within a magnetic levitation system. A pole array has a magnetic field. A levitation coil is positioned so that in response to motion of the magnetic field of the pole array a current is induced in the levitation coil. A first drive coil having a magnetic field coupled to drive the pole array also has a magnetic flux which induces a parasitic current in the levitation coil. A second drive coil having a magnetic field is positioned to attenuate the parasitic current in the levitation coil by canceling the magnetic flux of the first drive coil which induces the parasitic current. Steps in the method include generating a magnetic field with a pole array for levitating an object; inducing current in a levitation coil in response to motion of the magnetic field of the pole array; generating a magnetic field with a first drive coil for propelling the object; and generating a magnetic field with a second drive coil for attenuating effects of the magnetic field of the first drive coil on the current in the levitation coil.

  8. Magnetic induction pneumography: a planar coil system for continuous monitoring of lung function via contactless measurements

    Directory of Open Access Journals (Sweden)

    Doga Gursoy

    2010-11-01

    Full Text Available Continuous monitoring of lung function is of particular interest to the mechanically ventilated patients during critical care. Recent studies have shown that magnetic induction measurements with single coils provide signals which are correlated with the lung dynamics and this idea is extended here by using a 5 by 5 planar coil matrix for data acquisition in order to image the regional thoracic conductivity changes. The coil matrix can easily be mounted onto the patient bed, and thus, the problems faced in methods that use contacting sensors can readily be eliminated and the patient comfort can be improved. In the proposed technique, the data are acquired by successively exciting each coil in order to induce an eddy-current density within the dorsal tissues and measuring the corresponding response magnetic field strength by the remaining coils. The recorded set of data is then used to reconstruct the internal conductivity distribution by means of algorithms that minimize the residual norm between the estimated and measured data. To investigate the feasibility of the technique, the sensitivity maps and the point spread functions at different locations and depths were studied. To simulate a realistic scenario, a chest model was generated by segmenting the tissue boundaries from NMR images. The reconstructions of the ventilation distribution and the development of an edematous lung injury were presented. The imaging artifacts caused by either the incorrect positioning of the patient or the expansion of the chest wall due to breathing were illustrated by simulations.

  9. Electrodynamics the field-free approach : electrostatics, magnetism, induction, relativity and field theory

    CERN Document Server

    Prytz, Kjell

    2015-01-01

    This book is intended as an undergraduate textbook in electrodynamics at basic or advanced level. The objective is to attain a general understanding of the electrodynamic theory and its basic experiments and phenomena in order to form a foundation for further studies in the engineering sciences as well as in modern quantum physics. The outline of the book is obtained from the following principles: •         Base the theory on the concept of force and mutual interaction •         Connect the theory to experiments and observations accessible to the student •         Treat the electric, magnetic and inductive phenomena cohesively with respect to force, energy, dipoles and material •         Present electrodynamics using the same principles as in the preceding mechanics course •         Aim at explaining that theory of relativity is based on the magnetic effect •         Introduce field theory after the basic phenomena have been explored in terms of forc...

  10. Electroporation of cells using EM induction of ac fields by a magnetic stimulator

    International Nuclear Information System (INIS)

    Chen, C; Robinson, M P; Evans, J A; Smye, S W; O'Toole, P

    2010-01-01

    This paper describes a method of effectively electroporating mammalian cell membranes with pulsed alternating-current (ac) electric fields at field strengths of 30-160 kV m -1 . Although many in vivo electroporation protocols entail applying square wave or monotonically decreasing pulses via needles or electrode plates, relatively few have explored the use of pulsed ac fields. Following our previous study, which established the effectiveness of ac fields for electroporating cell membranes, a primary/secondary coil system was constructed to produce sufficiently strong electric fields by electromagnetic induction. The primary coil was formed from the applicator of an established transcranial magnetic stimulation (TMS) system, while the secondary coil was a purpose-built device of a design which could eventually be implanted into tissue. The effects of field strength, pulse interval and cumulative exposure time were investigated using microscopy and flow cytometry. Results from experiments on concentrated cell suspensions showed an optimized electroporation efficiency of around 50%, demonstrating that electroporation can be practicably achieved by inducing such pulsed ac fields. This finding confirms the possibility of a wide range of in vivo applications based on magnetically coupled ac electroporation.

  11. Electroporation of cells using EM induction of ac fields by a magnetic stimulator

    Energy Technology Data Exchange (ETDEWEB)

    Chen, C; Robinson, M P [Department of Electronics, University of York, Heslington, York YO10 5DD (United Kingdom); Evans, J A [Academic Unit of Medical Physics, University of Leeds, Leeds LS2 9JT (United Kingdom); Smye, S W [Department of Medical Physics and Engineering, Leeds Teaching Hospitals, St. James' s University Hospital, Leeds LS9 7TF (United Kingdom); O' Toole, P [Department of Biology, University of York, Heslington, York YO10 5DD (United Kingdom)

    2010-02-21

    This paper describes a method of effectively electroporating mammalian cell membranes with pulsed alternating-current (ac) electric fields at field strengths of 30-160 kV m{sup -1}. Although many in vivo electroporation protocols entail applying square wave or monotonically decreasing pulses via needles or electrode plates, relatively few have explored the use of pulsed ac fields. Following our previous study, which established the effectiveness of ac fields for electroporating cell membranes, a primary/secondary coil system was constructed to produce sufficiently strong electric fields by electromagnetic induction. The primary coil was formed from the applicator of an established transcranial magnetic stimulation (TMS) system, while the secondary coil was a purpose-built device of a design which could eventually be implanted into tissue. The effects of field strength, pulse interval and cumulative exposure time were investigated using microscopy and flow cytometry. Results from experiments on concentrated cell suspensions showed an optimized electroporation efficiency of around 50%, demonstrating that electroporation can be practicably achieved by inducing such pulsed ac fields. This finding confirms the possibility of a wide range of in vivo applications based on magnetically coupled ac electroporation.

  12. Wireless thin film transistor based on micro magnetic induction coupling antenna.

    Science.gov (United States)

    Jun, Byoung Ok; Lee, Gwang Jun; Kang, Jong Gu; Kim, Seunguk; Choi, Ji-Woong; Cha, Seung Nam; Sohn, Jung Inn; Jang, Jae Eun

    2015-12-22

    A wireless thin film transistor (TFT) structure in which a source/drain or a gate is connected directly to a micro antenna to receive or transmit signals or power can be an important building block, acting as an electrical switch, a rectifier or an amplifier, for various electronics as well as microelectronics, since it allows simple connection with other devices, unlike conventional wire connections. An amorphous indium gallium zinc oxide (α-IGZO) TFT with magnetic antenna structure was fabricated and studied for this purpose. To enhance the induction coupling efficiency while maintaining the same small antenna size, a magnetic core structure consisting of Ni and nanowires was formed under the antenna. With the micro-antenna connected to a source/drain or a gate of the TFT, working electrical signals were well controlled. The results demonstrated the device as an alternative solution to existing wire connections which cause a number of problems in various fields such as flexible/wearable devices, body implanted devices, micro/nano robots, and sensors for the 'internet of things' (IoT).

  13. Wireless thin film transistor based on micro magnetic induction coupling antenna

    Science.gov (United States)

    Jun, Byoung Ok; Lee, Gwang Jun; Kang, Jong Gu; Kim, Seunguk; Choi, Ji-Woong; Cha, Seung Nam; Sohn, Jung Inn; Jang, Jae Eun

    2015-12-01

    A wireless thin film transistor (TFT) structure in which a source/drain or a gate is connected directly to a micro antenna to receive or transmit signals or power can be an important building block, acting as an electrical switch, a rectifier or an amplifier, for various electronics as well as microelectronics, since it allows simple connection with other devices, unlike conventional wire connections. An amorphous indium gallium zinc oxide (α-IGZO) TFT with magnetic antenna structure was fabricated and studied for this purpose. To enhance the induction coupling efficiency while maintaining the same small antenna size, a magnetic core structure consisting of Ni and nanowires was formed under the antenna. With the micro-antenna connected to a source/drain or a gate of the TFT, working electrical signals were well controlled. The results demonstrated the device as an alternative solution to existing wire connections which cause a number of problems in various fields such as flexible/wearable devices, body implanted devices, micro/nano robots, and sensors for the ‘internet of things’ (IoT).

  14. Reconstruction artefacts in magnetic induction tomography due to patient's movement during data acquisition

    International Nuclear Information System (INIS)

    Gürsoy, D; Scharfetter, H

    2009-01-01

    Magnetic induction tomography (MIT) attempts to obtain the distribution of passive electrical properties inside the body. Eddy currents are induced in the body using an array of transmitter coils and the magnetic fields of these currents are measured by receiver coils. In clinical usage, the relative position of the coils to the body can change during data acquisition because of the expected/unexpected movements of the patient. Especially in respiration monitoring these movements will inevitably cause artefacts in the reconstructed images. In this paper, this effect was investigated for both state and frequency differential variants of MIT. It was found that a slight shift of the body in the transverse plane causes spurious perturbations on the surface. In reconstructions, this artefact on the surface propagates towards the centre in an oscillatory manner. It was observed that the movement can corrupt all the valuable information in state differential MIT, while frequency differential MIT seems more robust against movement effects. A filtering strategy is offered in order to decrease the movement artefacts in the images. To this end, monitoring of the patient's movement during data acquisition is required

  15. A new method for detecting cerebral hemorrhage in rabbits by magnetic inductive phase shift.

    Science.gov (United States)

    Jin, Gui; Sun, Jian; Qin, Mingxin; Tang, Qinghua; Xu, Lin; Ning, Xu; Xu, Jia; Pu, Xianjie; Chen, Mingsheng

    2014-02-15

    Cerebral hemorrhage, which is an important clinical problem, is often monitored and studied using expensive devices, such as magnetic resonance imaging (MRI) and positron emission tomography (PET) that are unavailable in economically underdeveloped regions. Magnetic induction tomography (MIT) is a new type of non-contact, non-invasive, and low-cost detection technology, and exhibits prospects for wide application, especially for the detection of brain diseases. However, the previous studies on MIT have focused on laboratory models and rarely on in vivo applications because the induced signals produced by biological tissues are notably weak. Based on the symmetry between the two brain hemispheres and the fact that a local brain hemorrhage will not affect the contra-lateral hemisphere, a symmetric cancellation-type sensor detection system, which is characterized by one excitation coil and two receiving coils, was designed to improve the detection sensitivity of MIT. This method was subsequently used to detect the occurrence of cerebral hematomas in rabbits. The average phase drift induced by a 3-ml injection of autologous blood was 1.885°, which is a fivefold improvement compared with the traditional single excitation coil and single receiving coil method. The results indicate that this system has high sensitivity and anti-interference ability and high practical value. © 2013 Published by Elsevier B.V.

  16. Acoustic Source Analysis of Magnetoacoustic Tomography With Magnetic Induction for Conductivity Gradual-Varying Tissues.

    Science.gov (United States)

    Wang, Jiawei; Zhou, Yuqi; Sun, Xiaodong; Ma, Qingyu; Zhang, Dong

    2016-04-01

    As a multiphysics imaging approach, magnetoacoustic tomography with magnetic induction (MAT-MI) works on the physical mechanism of magnetic excitation, acoustic vibration, and transmission. Based on the theoretical analysis of the source vibration, numerical studies are conducted to simulate the pathological changes of tissues for a single-layer cylindrical conductivity gradual-varying model and estimate the strengths of sources inside the model. The results suggest that the inner source is generated by the product of the conductivity and the curl of the induced electric intensity inside conductivity homogeneous medium, while the boundary source is produced by the cross product of the gradient of conductivity and the induced electric intensity at conductivity boundary. For a biological tissue with low conductivity, the strength of boundary source is much higher than that of the inner source only when the size of conductivity transition zone is small. In this case, the tissue can be treated as a conductivity abrupt-varying model, ignoring the influence of inner source. Otherwise, the contributions of inner and boundary sources should be evaluated together quantitatively. This study provide basis for further study of precise image reconstruction of MAT-MI for pathological tissues.

  17. Comparitive study of the influence of harmonic voltage distortion on the efficiency of induction machines versus line start permanent magnet machines

    OpenAIRE

    Debruyne, Colin; Derammelaere, Stijn; Desmet, Jan; Vandevelde, Lieven

    2012-01-01

    Induction machines have nearly reached their maximal efficiency. In order to further increase the efficiency the use of permanent magnets in combination with the robust design of the induction machine is being extensively researched. These so-called line start permanent magnet machines have an increased efficiency in sine wave conditions in respect to standard induction machines, however the efficiency of these machines is less researched under distorted voltage conditions. This paper compare...

  18. Magnetic field emission comparison at different quality factors with series-series compensation network for inductive power transfer to vehicles

    DEFF Research Database (Denmark)

    Batra, Tushar; Schaltz, Erik

    2014-01-01

    Inductive power transfer is non-contact transfer of energy by means of magnetic fields. A higher secondary side quality factor at fixed input current ensures a linear increase in power transfer across the air gap. But also at the same time magnetic emissions to the surroundings increase. First...... of all in this paper an analytic expression for comparing the magnetic emissions at different quality factors is introduced. It is shown with help of simulations on Comsol that emissions have a lower increase as compared to linear increase in the power transferred with the quality factor as suggested...

  19. Magnetoacoustic Tomography with Magnetic Induction (MAT-MI) for Imaging Electrical Conductivity of Biological Tissue: A Tutorial Review

    Science.gov (United States)

    Li, Xu; Yu, Kai; He, Bin

    2016-01-01

    Magnetoacoustic tomography with magnetic induction (MAT-MI) is a noninvasive imaging method developed to map electrical conductivity of biological tissue with millimeter level spatial resolution. In MAT-MI, a time-varying magnetic stimulation is applied to induce eddy current inside the conductive tissue sample. With the existence of a static magnetic field, the Lorentz force acting on the induced eddy current drives mechanical vibrations producing detectable ultrasound signals. These ultrasound signals can then be acquired to reconstruct a map related to the sample’s electrical conductivity contrast. This work reviews fundamental ideas of MAT-MI and major techniques developed in these years. First, the physical mechanisms underlying MAT-MI imaging are described including the magnetic induction and Lorentz force induced acoustic wave propagation. Second, experimental setups and various imaging strategies for MAT-MI are reviewed and compared together with the corresponding experimental results. In addition, as a recently developed reverse mode of MAT-MI, magneto-acousto-electrical tomography with magnetic induction (MAET-MI) is briefly reviewed in terms of its theory and experimental studies. Finally, we give our opinions on existing challenges and future directions for MAT-MI research. With all the reported and future technical advancement, MAT-MI has the potential to become an important noninvasive modality for electrical conductivity imaging of biological tissue. PMID:27542088

  20. Dual excitation acoustic paramagnetic logging tool

    Energy Technology Data Exchange (ETDEWEB)

    Vail, III, William B. (Bothell, WA)

    1989-01-01

    New methods and apparatus are disclosed which allow measurement of the presence of oil and water in gelogical formations using a new physical effect called the Acoustic Paramagnetic Logging Effect (APLE). The presence of petroleum in formation causes a slight increase in the earth's magnetic field in the vicinity of the reservoir. This is the phenomena of paramagnetism. Application of an acoustic source to a geological formation at the Larmor frequency of the nucleous present causes the paramagnetism of the formation to disappear. This results in a decrease in the earth's magnetic field in the vicinity of the oil bearing formation. Repetitively frequency sweeping the acoustic source through the Larmor frequency of the nucleons present (approx. 2 kHz) causes an amplitude modulation of the earth's magnetic field which is a consequence of the APLE. The amplitude modulation of the earth's magnetic field is measured with an induction coil gradiometer and provides a direct measure of the amount of oil and water in the excitation zone of the formation. The phase of the signal is used to infer the longitudinal relaxation times of the fluids present, which results in the ability in general to separate oil and water and to measure the viscosity of the oil present. Such measurements may be preformed in open boreholes and in cased well bores. The Dual Excitation Acoustic Paramagnetic Logging Tool employing two acoustic sources is also described.

  1. Wireless Energy Transfer Using Resonant Magnetic Induction for Electric Vehicle Charging Application

    Science.gov (United States)

    Dahal, Neelima

    The research work for this thesis is based on utilizing resonant magnetic induction for wirelessly charging electric vehicles. The background theory for electromagnetic induction between two conducting loops is given and it is shown that an RLCequivalent circuit can be used to model the loops. An analysis of the equivalent circuit is used to show how two loosely coupled loops can be made to exchange energy efficiently by operating them at a frequency which is the same as the resonant frequency of both. Furthermore, it is shown that the efficiency is the maximum for critical coupling (determined by the quality factors of the loops), and increasing the coupling beyond critical coupling causes double humps to appear in the transmission efficiency versus frequency spectrum. In the experiment, as the loops are brought closer together which increases the coupling between them, doubles humps, as expected from the equivalent circuit analysis is seen. Two models for wireless energy transfer are identified: basic model and array model. The basic model consists of the two loosely coupled loops, the transmitter and the receiver. The array model consists of a 2 x 2 array of the transmitter and three parasites, and the receiver. It is shown that the array model allows more freedom for receiver placement at the cost of degraded transmission efficiency compared to the basic model. Another important part of the thesis is software validation. HFSS-IE and 4NEC2 are the software tools used and the simulation results for wire antennas are compared against references obtained from a textbook and a PhD dissertation. It is shown that the simulations agree well with the references and also with each other.

  2. Minimum Electric Field Exposure for Seizure Induction with Electroconvulsive Therapy and Magnetic Seizure Therapy.

    Science.gov (United States)

    Lee, Won H; Lisanby, Sarah H; Laine, Andrew F; Peterchev, Angel V

    2017-05-01

    Lowering and individualizing the current amplitude in electroconvulsive therapy (ECT) has been proposed as a means to produce stimulation closer to the neural activation threshold and more focal seizure induction, which could potentially reduce cognitive side effects. However, the effect of current amplitude on the electric field (E-field) in the brain has not been previously linked to the current amplitude threshold for seizure induction. We coupled MRI-based E-field models with amplitude titrations of motor threshold (MT) and seizure threshold (ST) in four nonhuman primates (NHPs) to determine the strength, distribution, and focality of stimulation in the brain for four ECT electrode configurations (bilateral, bifrontal, right-unilateral, and frontomedial) and magnetic seizure therapy (MST) with cap coil on vertex. At the amplitude-titrated ST, the stimulated brain subvolume (23-63%) was significantly less than for conventional ECT with high, fixed current (94-99%). The focality of amplitude-titrated right-unilateral ECT (25%) was comparable to cap coil MST (23%), demonstrating that ECT with a low current amplitude and focal electrode placement can induce seizures with E-field as focal as MST, although these electrode and coil configurations affect differently specific brain regions. Individualizing the current amplitude reduced interindividual variation in the stimulation focality by 40-53% for ECT and 26% for MST, supporting amplitude individualization as a means of dosing especially for ECT. There was an overall significant correlation between the measured amplitude-titrated ST and the prediction of the E-field models, supporting a potential role of these models in dosing of ECT and MST. These findings may guide the development of seizure therapy dosing paradigms with improved risk/benefit ratio.

  3. Software for evaluating magnetic induction field generated by power lines: implementation of a new algorithm

    International Nuclear Information System (INIS)

    Comelli, M.; Benes, M.; Bampo, A.; Villalta, R.

    2006-01-01

    The Regional Environment Protection Agency of Friuli Venezia Giulia (A.R.P.A. F.V.G., Italy) has performed an analysis on existing software designed to calculate magnetic induction field generated by power lines. As far as the agency requirements are concerned the tested programs display some difficulties in the immediate processing of electrical and geometrical data supplied by plant owners, and in certain cases turn out to be inadequate in representing complex configurations of power lines. Furthermore, none of them is preset for cyclic calculus to determine the time evolution of induction in a certain exposure area. Finally, the output data are not immediately importable by ArcView, the G.I.S. used by A.R.P.A. F.V.G., and it is not always possible to implement the territory orography to determine the field at specified heights above the ground. P.h.i.d.e.l., an innovative software, tackles and works out al l the above mentioned problems. The power line wires interested in its implementation are represented by poly lines, and the field is analytically calculated, with no further approximation, not even when more power lines are concerned. Therefore, the obtained results, when compared with those of other programs, are the closest to experimental measurements. The output data can be employed both in G.I.S. and Excel environments, allowing the immediate overlaying of digital cartography and the determining of the 3 and 10 μT bands, in compliance with the Italian Decree of the President of the Council of Ministers of 8 July 2003. (authors)

  4. Analysis of Operating Performance and Three Dimensional Magnetic Field of High Voltage Induction Motors with Stator Chute

    Directory of Open Access Journals (Sweden)

    WANG Qing-shan

    2017-06-01

    Full Text Available In view of the difficulties on technology of rotor chute in high voltage induction motor,the desig method adopted stator chute structure is put forward. The mathematical model of three dimensional nonlinear transient field for solving stator chute in high voltage induction motor is set up. Through the three dimensional entity model of motor,three dimensional finite element method based on T,ψ - ψ electromagnetic potential is adopted for the analysis and calculation of stator chute in high voltage induction motor under rated condition. The distributions long axial of fundamental wave magnetic field and tooth harmonic wave magnetic field are analyzed after stator chute,and the weakening effects on main tooth harmonic magnetic field are researched. Further more,the comparison analysis of main performance parameters of chute and straight slot is carried out under rated condition. The results show that the electrical performance of stator chute is better than that of straight slot in high voltage induction motor,and the tooth harmonic has been sharply decreased

  5. Huge Inverse Magnetization Generated by Faraday Induction in Nano-Sized Au@Ni Core@Shell Nanoparticles.

    Science.gov (United States)

    Kuo, Chen-Chen; Li, Chi-Yen; Lee, Chi-Hung; Li, Hsiao-Chi; Li, Wen-Hsien

    2015-08-25

    We report on the design and observation of huge inverse magnetizations pointing in the direction opposite to the applied magnetic field, induced in nano-sized amorphous Ni shells deposited on crystalline Au nanoparticles by turning the applied magnetic field off. The magnitude of the induced inverse magnetization is very sensitive to the field reduction rate as well as to the thermal and field processes before turning the magnetic field off, and can be as high as 54% of the magnetization prior to cutting off the applied magnetic field. Memory effect of the induced inverse magnetization is clearly revealed in the relaxation measurements. The relaxation of the inverse magnetization can be described by an exponential decay profile, with a critical exponent that can be effectively tuned by the wait time right after reaching the designated temperature and before the applied magnetic field is turned off. The key to these effects is to have the induced eddy current running beneath the amorphous Ni shells through Faraday induction.

  6. Huge Inverse Magnetization Generated by Faraday Induction in Nano-Sized Au@Ni Core@Shell Nanoparticles

    Directory of Open Access Journals (Sweden)

    Chen-Chen Kuo

    2015-08-01

    Full Text Available We report on the design and observation of huge inverse magnetizations pointing in the direction opposite to the applied magnetic field, induced in nano-sized amorphous Ni shells deposited on crystalline Au nanoparticles by turning the applied magnetic field off. The magnitude of the induced inverse magnetization is very sensitive to the field reduction rate as well as to the thermal and field processes before turning the magnetic field off, and can be as high as 54% of the magnetization prior to cutting off the applied magnetic field. Memory effect of the induced inverse magnetization is clearly revealed in the relaxation measurements. The relaxation of the inverse magnetization can be described by an exponential decay profile, with a critical exponent that can be effectively tuned by the wait time right after reaching the designated temperature and before the applied magnetic field is turned off. The key to these effects is to have the induced eddy current running beneath the amorphous Ni shells through Faraday induction.

  7. Huge Inverse Magnetization Generated by Faraday Induction in Nano-Sized Au@Ni Core@Shell Nanoparticles

    Science.gov (United States)

    Kuo, Chen-Chen; Li, Chi-Yen; Lee, Chi-Hung; Li, Hsiao-Chi; Li, Wen-Hsien

    2015-01-01

    We report on the design and observation of huge inverse magnetizations pointing in the direction opposite to the applied magnetic field, induced in nano-sized amorphous Ni shells deposited on crystalline Au nanoparticles by turning the applied magnetic field off. The magnitude of the induced inverse magnetization is very sensitive to the field reduction rate as well as to the thermal and field processes before turning the magnetic field off, and can be as high as 54% of the magnetization prior to cutting off the applied magnetic field. Memory effect of the induced inverse magnetization is clearly revealed in the relaxation measurements. The relaxation of the inverse magnetization can be described by an exponential decay profile, with a critical exponent that can be effectively tuned by the wait time right after reaching the designated temperature and before the applied magnetic field is turned off. The key to these effects is to have the induced eddy current running beneath the amorphous Ni shells through Faraday induction. PMID:26307983

  8. Induction linacs

    International Nuclear Information System (INIS)

    Keefe, D.

    1986-07-01

    The principle of linear induction acceleration is described, and examples are given of practical configurations for induction linacs. These examples include the Advanced Technology Accelerator, Long Pulse Induction Linac, Radial Line Accelerator (RADLAC), and Magnetically-Insulated Electron-Focussed Ion Linac. A related concept, the auto accelerator, is described in which the high-current electron-beam technology in the sub-10 MeV region is exploited to produce electron beams at energies perhaps as high as the 100 to 1000 MeV range. Induction linacs for ions are also discussed. The efficiency of induction linear acceleration is analyzed

  9. Hardware for quasi-single-shot multifrequency magnetic induction tomography (MIT): the Graz Mk2 system

    International Nuclear Information System (INIS)

    Scharfetter, H; Köstinger, A; Issa, S

    2008-01-01

    Magnetic induction tomography (MIT) has been suggested by several groups for the contact-less mapping of the passive electrical properties of tissues via AC magnetic fields in the frequency range between several tens of kHz and several tens of MHz. Multifrequency MIT as an analog to multifrequency EIT has been tried and first image reconstructions have been demonstrated with phantoms. MIT appears to yield comparable images to EIT but offers the advantage of being non-contacting. In the beta-dispersion range of most tissues the method is challenging because the signals are very small and buried in noise. In order to minimize drifts and systematic errors fast data acquisition is therefore pivotal. This paper presents a method for single-shot MIT which allows us to acquire the data for a multifrequency image with an analog bandwidth of 50 kHz–1.5 MHz which covers a good part of the β-dispersion of many tissues. The transmit (TX) coils are simultaneously driven by individual power amplifiers with a multisinus pattern with up to 3 A pp . The amplifiers are configured as current sources so as not to perturb the excitation fields by inappropriately terminated coils. The separation of the different TX channels after reception is achieved by splitting up the carrier frequencies into individual subcarriers with a narrow spacing of at most 300 Hz. In this way every TX coil is identifiable by its own subcarrier but the whole excitation band is contained within a few kHz. The real and imaginary parts of the received signals are extracted efficiently with FFT. The system noise and the sources for low-frequency perturbations are analyzed and characterized

  10. Three-axis magnetic field induction sensor realized on buckled cantilever plate

    KAUST Repository

    Alfadhel, Ahmed; Carreno, Armando Arpys Arevalo; Foulds, Ian G.; Kosel, Jü rgen

    2013-01-01

    This work presents the fabrication and characterization of a three-axis induction sensor consisting of one planar microcoil, fixed on the substrate, and two microcoils fabricated on Bbuckled cantilever plates (BCP) oriented perpendicularly to the substrate and each other. The BCP allows an out-of-plane translation while preserving a direct connection to the substrate, which aids the routing of electrical lines. The fabricated sensor is integrated on a single substrate, allowing interaction and integration with other systems. The devices are fabricated using a MEMS polymer fabrication process. Different microcoil configurations are realized with 17-30 turns, 5 μm track width, and 15-20 μm track pitch. The sensor showed up to 6.8 nT/√Hz resolution to magnetic fields within a frequency range of 40 Hz to 1 MHz. The BCP concept provides a strikingly simple method to fabricate a three-axis field sensor that can readily be integrated with electronic circuits, and the sensor's performance can easily be adjusted within a wide range by changing the dimensions of the coils. © 2013 IEEE.

  11. Three-axis magnetic field induction sensor realized on buckled cantilever plate

    KAUST Repository

    Alfadhel, Ahmed

    2013-07-01

    This work presents the fabrication and characterization of a three-axis induction sensor consisting of one planar microcoil, fixed on the substrate, and two microcoils fabricated on Bbuckled cantilever plates (BCP) oriented perpendicularly to the substrate and each other. The BCP allows an out-of-plane translation while preserving a direct connection to the substrate, which aids the routing of electrical lines. The fabricated sensor is integrated on a single substrate, allowing interaction and integration with other systems. The devices are fabricated using a MEMS polymer fabrication process. Different microcoil configurations are realized with 17-30 turns, 5 μm track width, and 15-20 μm track pitch. The sensor showed up to 6.8 nT/√Hz resolution to magnetic fields within a frequency range of 40 Hz to 1 MHz. The BCP concept provides a strikingly simple method to fabricate a three-axis field sensor that can readily be integrated with electronic circuits, and the sensor\\'s performance can easily be adjusted within a wide range by changing the dimensions of the coils. © 2013 IEEE.

  12. Time-difference imaging of magnetic induction tomography in a three-layer brain physical phantom

    International Nuclear Information System (INIS)

    Liu, Ruigang; Li, Ye; Fu, Feng; You, Fusheng; Shi, Xuetao; Dong, Xiuzhen

    2014-01-01

    Magnetic induction tomography (MIT) is a contactless and noninvasive technique to reconstruct the conductivity distribution in a human cross-section. In this paper, we want to study the feasibility of imaging the low-contrast perturbation and small volume object in human brains. We construct a three-layer brain physical phantom which mimics the real conductivity distribution of brains by introducing an artificial skull layer. Using our MIT data acquisition system on this phantom and differential algorithm, we have obtained a series of reconstructed images of conductivity perturbation objects. All of the conductivity perturbation objects in the brain phantom can be clearly distinguished in the reconstructed images. The minimum detectable conductivity difference between the object and the background is 0.03 S m −1  (12.5%). The minimum detectable inner volume of the objects is 3.4 cm 3 . The three-layer brain physical phantom is able to simulate the conductivity distribution of the main structures of a human brain. The images of the low-contrast perturbation and small volume object show the prospect of MIT in the future. (paper)

  13. Dry etching of ITO by magnetic pole enhanced inductively coupled plasma for display and biosensing devices

    Energy Technology Data Exchange (ETDEWEB)

    Meziani, T. [European Commission, Joint Research Centre, Institute for Health and Consumer Protection, 21020 Ispra (Vatican City State, Holy See,) (Italy)]. E-mail: tarik.meziani@jrc.it; Colpo, P. [European Commission, Joint Research Centre, Institute for Health and Consumer Protection, 21020 Ispra (Va) (Italy)]. E-mail: pascal.colpo@jrc.it; Lambertini, V. [Centro Ricerche Fiat, Strada Torino 50, 10043 Orbassano (TO) (Italy); Ceccone, G. [European Commission, Joint Research Centre, Institute for Health and Consumer Protection, 21020 Ispra (Va) (Italy); Rossi, F. [European Commission, Joint Research Centre, Institute for Health and Consumer Protection, 21020 Ispra (Va) (Italy)

    2006-03-15

    The dry etching of indium tin oxide (ITO) layers deposited on glass substrates was investigated in a high density inductively coupled plasma (ICP) source. This innovative low pressure plasma source uses a magnetic core in order to concentrate the electromagnetic energy on the plasma and thus provides for higher plasma density and better uniformity. Different gas mixtures were tested containing mainly hydrogen, argon and methane. In Ar/H{sub 2} mixtures and at constant bias voltage (-100 V), the etch rate shows a linear dependence with input power varying the same way as the ion density, which confirms the hypothesis that the etching process is mainly physical. In CH{sub 4}/H{sub 2} mixtures, the etch rate goes through a maximum for 10% CH{sub 4} indicating a participation of the radicals to the etching process. However, the etch rate remains quite low with this type of gas mixture (around 10 nm/min) because the etching mechanism appears to be competing with a deposition process. With CH{sub 4}/Ar mixtures, a similar feature appeared but the etch rate was much higher, reaching 130 nm/min at 10% of CH{sub 4} in Ar. The increase in etch rate with the addition of a small quantity of methane indicates that the physical etching process is enhanced by a chemical mechanism. The etching process was monitored by optical emission spectroscopy that appeared to be a valuable tool for endpoint detection.

  14. A multi-channel magnetic induction tomography measurement system for human brain model imaging

    International Nuclear Information System (INIS)

    Xu, Zheng; Luo, Haijun; He, Wei; He, Chuanhong; Song, Xiaodong; Zahng, Zhanglong

    2009-01-01

    This paper proposes a multi-channel magnetic induction tomography measurement system for biological conductivity imaging in a human brain model. A hemispherical glass bowl filled with a salt solution is used as the human brain model; meanwhile, agar blocks of different conductivity are placed in the solution to simulate the intracerebral hemorrhage. The excitation and detection coils are fixed co-axially, and the axial gradiometer is used as the detection coil in order to cancel the primary field. On the outer surface of the glass bowl, 15 sensor units are arrayed in two circles as measurement parts, and a single sensor unit for canceling the phase drift is placed beside the glass bowl. The phase sensitivity of our system is 0.204°/S m −1 with the excitation frequency of 120 kHz and the phase noise is in the range of −0.03° to +0.05°. Only the coaxial detection coil is available for each excitation coil; therefore, 15 phase data are collected in each measurement turn. Finally, the two-dimensional images of conductivity distribution are obtained using an interpolation algorithm. The frequency-varying experiment indicates that the imaging quality becomes better as the excitation frequency is increased

  15. Procedure to evaluate the ionizing radiation influence over LED and magnetic induction lamps

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Otavio Luis de; Menzel, Silvio Carlos, E-mail: otavioluis@ipen.br, E-mail: scmenzel@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (CEN/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Engenharia Nuclear; Ribas, Jacinto Oliveira, E-mail: jacinto@eletronuclear.gov.br [Eletrobras Termonuclear S.A. (ELETRONUCLEAR), Angra dos Reis, RJ (Brazil). Gerencia de Eletrica e Instrumentacao

    2015-07-01

    The goal of this paper is to present a methodology to evaluate the ionizing radiation influence over Lighting Emitting Diode (LED) and Magnetic Induction (MI) lamps as they use a lot of electronic in their power supply. Considering they have a huge lifetime it is interesting to apply this technology into environments under ionizing radiation, such as a nuclear facility. Thus, it is possible to increase the period between two consecutive maintenance, reduce the repair and global maintenance costs and reduce the operational personnel exposure to ionizing radiation. In this context it is going to be presented a scheme to select different LED and MI lamps available in the Brazilian market, a methodology to irradiate several lamp samples according various radiation levels that can be found in the facilities and the electrical and photometric evaluation to be performed. Considering this methodology it will be possible to analyze the lamps capacity to withstand ionizing radiation, under regular operating conditions of the facilities and its effects in the performance and lifetime of the selected lamps. Thus, the procedures suggested in this work can be used as a guide to perform experiments and analysis to find specific lamps that can reduce the global maintenance costs and the personnel exposure. Hereafter, several lamps are going to be acquired and the tests performed, according the procedures here described. (author)

  16. Procedure to evaluate the ionizing radiation influence over LED and magnetic induction lamps

    International Nuclear Information System (INIS)

    Oliveira, Otavio Luis de; Menzel, Silvio Carlos; Ribas, Jacinto Oliveira

    2015-01-01

    The goal of this paper is to present a methodology to evaluate the ionizing radiation influence over Lighting Emitting Diode (LED) and Magnetic Induction (MI) lamps as they use a lot of electronic in their power supply. Considering they have a huge lifetime it is interesting to apply this technology into environments under ionizing radiation, such as a nuclear facility. Thus, it is possible to increase the period between two consecutive maintenance, reduce the repair and global maintenance costs and reduce the operational personnel exposure to ionizing radiation. In this context it is going to be presented a scheme to select different LED and MI lamps available in the Brazilian market, a methodology to irradiate several lamp samples according various radiation levels that can be found in the facilities and the electrical and photometric evaluation to be performed. Considering this methodology it will be possible to analyze the lamps capacity to withstand ionizing radiation, under regular operating conditions of the facilities and its effects in the performance and lifetime of the selected lamps. Thus, the procedures suggested in this work can be used as a guide to perform experiments and analysis to find specific lamps that can reduce the global maintenance costs and the personnel exposure. Hereafter, several lamps are going to be acquired and the tests performed, according the procedures here described. (author)

  17. Improved magnetic induction heating of nanoferrites for hyperthermia applications: Correlation with colloidal stability and magneto-structural properties

    Energy Technology Data Exchange (ETDEWEB)

    Khot, V.M., E-mail: wish_khot@yahoo.co.in [Center for Interdisciplinary Research, D. Y. Patil University, Kolhapur 416006 (India); Salunkhe, A.B. [Advanced Materials Laboratory, Department of Physics, Savitribai Phule University of Pune (India); Ruso, J.M. [Soft Matter and Molecular Biophysics Group, Applied Physics Department, University of Santiago de Compostela, Santiago de Compostela (Spain); Pawar, S.H. [Center for Interdisciplinary Research, D. Y. Patil University, Kolhapur 416006 (India)

    2015-06-15

    Nanoferrites with compositions Mn{sub 0.4}Zn{sub 0.6}Fe{sub 2}O{sub 4}, Co{sub 0.4}Zn{sub 0.6}Fe{sub 2}O{sub 4}, Ni{sub 0.4}Zn{sub 0.6}Fe{sub 2}O{sub 4} (MZF, CZF and NZF respectively) coated with polyethylene glycol (PEG) were prepared in a single step. These nanoparticles are highly water dispersible with zeta potential values between 14 and 21 mV. Magnetic induction heating characteristics of these NPs have been studied as a function of magnetic field amplitude from 6.7 to 26.7 kA m{sup −1} (at fixed frequency 265 kHz) and concentration of nanoparticles. Notable enhancement in specific absorption rate (334.5 W g{sup −1}) by CZF nanoparticles has been observed. This enhanced induction heating properties have been studied and correlated with colloidal stability and magnetostructural properties such as tuned magnetic anisotropy arising from zinc substitution. Cytotoxicity of synthesized mixed ferrites has been evaluated in vitro on HeLa cell lines using MTT assay to explore their use as heating agents in magnetic hyperthermia. - Highlights: • Magnetic nanoferrites (sizes 8–12 nm) with improved specific absorption rate (334.5 W g{sup −1}) at lowest particle concentration have been prepared • The results have been explained by correlating colloidal stability and magnetostructural properties such as magnetocrystalline anisotropy. • It has been shown that substitution of zinc tunes anisotropy of cobalt iron oxide within the value optimized previously in achieving high throughput in magnetic induction heating. • In vitro cytotoxicity proves nanoparticles are non-toxic suggesting their use as a potential heating agent in hyperthermia therapy.

  18. Improved magnetic induction heating of nanoferrites for hyperthermia applications: Correlation with colloidal stability and magneto-structural properties

    International Nuclear Information System (INIS)

    Khot, V.M.; Salunkhe, A.B.; Ruso, J.M.; Pawar, S.H.

    2015-01-01

    Nanoferrites with compositions Mn 0.4 Zn 0.6 Fe 2 O 4 , Co 0.4 Zn 0.6 Fe 2 O 4 , Ni 0.4 Zn 0.6 Fe 2 O 4 (MZF, CZF and NZF respectively) coated with polyethylene glycol (PEG) were prepared in a single step. These nanoparticles are highly water dispersible with zeta potential values between 14 and 21 mV. Magnetic induction heating characteristics of these NPs have been studied as a function of magnetic field amplitude from 6.7 to 26.7 kA m −1 (at fixed frequency 265 kHz) and concentration of nanoparticles. Notable enhancement in specific absorption rate (334.5 W g −1 ) by CZF nanoparticles has been observed. This enhanced induction heating properties have been studied and correlated with colloidal stability and magnetostructural properties such as tuned magnetic anisotropy arising from zinc substitution. Cytotoxicity of synthesized mixed ferrites has been evaluated in vitro on HeLa cell lines using MTT assay to explore their use as heating agents in magnetic hyperthermia. - Highlights: • Magnetic nanoferrites (sizes 8–12 nm) with improved specific absorption rate (334.5 W g −1 ) at lowest particle concentration have been prepared • The results have been explained by correlating colloidal stability and magnetostructural properties such as magnetocrystalline anisotropy. • It has been shown that substitution of zinc tunes anisotropy of cobalt iron oxide within the value optimized previously in achieving high throughput in magnetic induction heating. • In vitro cytotoxicity proves nanoparticles are non-toxic suggesting their use as a potential heating agent in hyperthermia therapy

  19. Intracerebral hemorrhage (ICH) evaluation with a novel magnetic induction sensor: a preliminary study using the Chinese head model.

    Science.gov (United States)

    Zhang, Ziyi; Liu, Peiguo; Zhou, Dongming; Zhang, Liang; Lei, Hengdong

    2014-01-01

    Biomedical magnetic induction measurement is a promising method for the detection of intracerebral hemorrhage (ICH), especially in China. Aiming at overcoming the problem of low sensitivity, a magnetic induction sensor is chosen to replace the conventional sensors. It uses a two-arm Archimedean spiral coil as the exciter and a circular coil as the receiver. In order to carry out high-fidelity simulations, the Chinese head model with real anatomical structure is introduced into this novel sensor for the first time. Simulations have been carried out upon early stage ICH measurements. By calculating the state sensitivity and time sensitivity of the perturbation phase of two types of sensors using the electromagnetic software, we conclude that the primary signal received can be largely reduced using the novel sensor, which could effectively increase the time and state sensitivity simultaneously.

  20. INDUCTION HEATING OF NON-MAGNETIC SHEET METALS IN THE FIELD OF A FLAT CIRCULAR MULTITURN SOLENOID

    Directory of Open Access Journals (Sweden)

    Y. Batygin

    2016-06-01

    Full Text Available The theoretical analysis of electromagnetic processes in the system for induction heating presented by a flat circular multiturn solenoid positioned above a plane of thin sheet non-magnetic metal has been conducted. The calculated dependences for the current induced in a metal sheet blank and ratio of transformation determined have been obtained. The maximal value of the transformation ratio with regard to spreading the eddy-currents over the whole area of the sheet metal has been determined.

  1. Investigating the Relationship between Cerebrospinal Fluid and Magnetic Induction Phase Shift in Rabbit Intracerebral hematoma expansion Monitoring by MRI

    OpenAIRE

    Chen, Mingsheng; Yan, Qingguang; Sun, Jian; Jin, Gui; Qin, Mingxin

    2017-01-01

    In a prior study of intracerebral hemorrhage monitoring using magnetic induction phase shift (MIPS), we found that MIPS signal changes occurred prior to those seen with intracranial pressure. However, the characteristic MIPS alert is not yet fully explained. Combining the brain physiology and MIPS theory, we propose that cerebrospinal fluid (CSF) may be the primary factor that leads to hematoma expansion being alerted by MIPS earlier than with intracranial pressure monitoring. This paper inve...

  2. Effect of Co content on structure and magnetic behaviors of high induction Fe-based amorphous alloys

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Rajat K., E-mail: rajat@nmlindia.org; Panda, Ashis K.; Mitra, Amitava

    2016-11-15

    The replacement of Fe with Co is investigated in the (Fe{sub 1−x}Co{sub x}){sub 79}Si{sub 8.5}B{sub 8.5}Nb{sub 3}Cu{sub 1} (x=0, 0.05, 0.2, 0.35, 0.5) amorphous alloys. The alloys are synthesized in the forms of ribbons by single roller melt spinning technique, and the structural and magnetic properties of annealed ribbons are characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM) and vibrating sample magnetometer (VSM), B–H curve tracer, respectively. All as-cast alloys are structurally amorphous, however, their magnetic properties are varying with Co addition. The Co addition within 5–20 at% results in moderate thermal stability, saturation induction, Curie temperature and lowest coercivity, while 35 at% Co causes highest saturation induction, coercivity, Curie temperature and lowest thermal stability. On devitrification, the magnetic properties change with the generation of α-FeCo nanocrystallites and (FeCo){sub 23}B{sub 6}, Fe{sub 2}B phases during primary and secondary crystallization stages, respectively. A small amount Co is advantageous for maintaining finer nanocrystallites in amorphous matrix even after annealing at 600 °C, leading to high saturation magnetization (>1.5 T) and low coercivity (~35 A/m). The improved magnetic properties at elevated temperatures indicate these alloys have a potential for high frequency transformer core applications. - Highlights: • The structural and magnetic behaviors of Fe based amorphous alloys have been investigated with the effect of Co content. • The Co has no adverse effect on amorphization of alloys. • A small amount Co causes the superior improvement of magnetic properties at elevated temperatures. • Therefore, it is important not only for academic research but also for industrial applied research.

  3. Influence of different kinds of rolling on the crystallographic texture and magnetic induction of a NOG 3 wt% Si steel

    Energy Technology Data Exchange (ETDEWEB)

    Silva, J.M.; Baêta Júnior, E.S.; Moraes, N.R.D.C.; Botelho, R.A. [Department of Mechanical and Materials Engineering, Military Institute of Engineering (IME), Praça General Tibúrcio, 80,Urca, Rio de Janeiro/RJ (Brazil); Felix, R.A.C. [Scientific Instrumentation and Mechanical Technology Laboratory, Brazilian Center for Physics Research (CBPF), Rua Dr. Xavier Sigaud, 150-Urca, Rio de Janeiro-RJ (Brazil); Brandao, L., E-mail: brandao@ime.eb.br [Department of Mechanical and Materials Engineering, Military Institute of Engineering (IME), Praça General Tibúrcio, 80,Urca, Rio de Janeiro/RJ (Brazil)

    2017-01-01

    The purpose of this work was to study the influence of different kinds of rolling on the magnetic properties of NOG steel, an electric steel widely used in electrical motors. These properties are highly correlated with the crystallographic texture of the material, which can be changed by rolling. Three kinds of rolling were examined: conventional rolling, cross-rolling and asymmetrical rolling. The crystallographic texture was determined by X-ray diffraction and the magnetic properties were calculated from a theoretical model that related the magnetic induction to crystallographic texture through the anisotropy energy. The results show that cross-rolling yields higher values of magnetic induction than the other processes. - Highlights: • The B{sub 50} of NOG steels was evaluated via texture for different rolling processes. • On comparison to all processes used, the cross-rolling led to highest average B{sub 50}. • Cross-rolling enhances Goss and γ-fiber after annealing. • The better B{sub 50} values were obtained for symmetrical and cross-rolling processes. • For asymmetric rolling process, cylinder diameter ratio changed slightly the texture.

  4. Magnetic induction strength on surface of a ferro-medium circular cylinder

    Directory of Open Access Journals (Sweden)

    M. Jin

    2016-09-01

    Full Text Available Based on the Ampere molecular current hypothesis and the Biot–Savart law, a magnetic model on the metal magnetic memory (MMM testing of a specimen is proposed. Relation between magnetic flux leakage (MFL and magnetization of a ferro-medium circular cylinder is set up. We can predict magnetization of material according to the MFL on surface of the circular cylinder.

  5. Coreless Linear Induction Motor (LIM) for Space-borne Electro-magnetic Mass Driver Applications

    Data.gov (United States)

    National Aeronautics and Space Administration — Large scale linear induction motors use ferromagnetic cores, but at high speed these cores choke the system’s ability to transform electrical energy into mechanical...

  6. Effects of Leakage Inductances on Magnetically Coupled Y-Source Network

    DEFF Research Database (Denmark)

    Siwakoti, Yam P.; Loh, Poh Chiang; Blaabjerg, Frede

    2014-01-01

    inductances must be small. This is often difficult to achieve in practice especially at high switching frequencies. It is therefore necessary to understand the effects that leakage inductances have on the performance of these converters. In this letter, we address these issues for the latest Y-source network......, showing in particular that voltage spikes will appear across its switching devices in some, but not all, cases. Experimental results verifying the findings have been obtained and presented at the end of this letter....

  7. Electrical description of a magnetic pole enhanced inductively coupled plasma source: Refinement of the transformer model by reverse electromagnetic modeling

    International Nuclear Information System (INIS)

    Meziani, T.; Colpo, P.; Rossi, F.

    2006-01-01

    The magnetic pole enhanced inductively coupled source (MaPE-ICP) is an innovative low-pressure plasma source that allows for high plasma density and high plasma uniformity, as well as large-area plasma generation. This article presents an electrical characterization of this source, and the experimental measurements are compared to the results obtained after modeling the source by the equivalent circuit of the transformer. In particular, the method applied consists in performing a reverse electromagnetic modeling of the source by providing the measured plasma parameters such as plasma density and electron temperature as an input, and computing the total impedance seen at the primary of the transformer. The impedance results given by the model are compared to the experimental results. This approach allows for a more comprehensive refinement of the electrical model in order to obtain a better fitting of the results. The electrical characteristics of the system, and in particular the total impedance, were measured at the inductive coil antenna (primary of the transformer). The source was modeled electrically by a finite element method, treating the plasma as a conductive load and taking into account the complex plasma conductivity, the value of which was calculated from the electron density and electron temperature measurements carried out previously. The electrical characterization of the inductive excitation source itself versus frequency showed that the source cannot be treated as purely inductive and that the effect of parasitic capacitances must be taken into account in the model. Finally, considerations on the effect of the magnetic core addition on the capacitive component of the coupling are made

  8. Non-chemotoxic induction of cancer cell death using magnetic nanowires

    KAUST Repository

    Contreras, Maria F.

    2015-03-01

    In this paper, we show that magnetic nanowires with weak magnetic fields and low frequencies can induce cell death via a mechanism that does not involve heat production. We incubated colon cancer cells with two concentrations (2.4 and 12 μg/mL) of nickel nanowires that were 35 nm in diameter and exposed the cells and nanowires to an alternating magnetic field (0.5 mT and 1 Hz or 1 kHz) for 10 or 30 minutes. This low-power field exerted a force on the magnetic nanowires, causing a mechanical disturbance to the cells. Transmission electron microscopy images showed that the nanostructures were internalized into the cells within 1 hour of incubation. Cell viability studies showed that the magnetic field and the nanowires separately had minor deleterious effects on the cells; however, when combined, the magnetic field and nanowires caused the cell viability values to drop by up to 39%, depending on the strength of the magnetic field and the concentration of the nanowires. Cell membrane leakage experiments indicated membrane leakage of 20%, suggesting that cell death mechanisms induced by the nanowires and magnetic field involve some cell membrane rupture. Results suggest that magnetic nanowires can kill cancer cells. The proposed process requires simple and low-cost equipment with exposure to only very weak magnetic fields for short time periods. © 2015 Contreras et al.

  9. Non-chemotoxic induction of cancer cell death using magnetic nanowires

    KAUST Repository

    Contreras, Maria F.; Sougrat, Rachid; Zaher, Amir Omar; Ravasi, Timothy; Kosel, Jü rgen

    2015-01-01

    In this paper, we show that magnetic nanowires with weak magnetic fields and low frequencies can induce cell death via a mechanism that does not involve heat production. We incubated colon cancer cells with two concentrations (2.4 and 12 μg/mL) of nickel nanowires that were 35 nm in diameter and exposed the cells and nanowires to an alternating magnetic field (0.5 mT and 1 Hz or 1 kHz) for 10 or 30 minutes. This low-power field exerted a force on the magnetic nanowires, causing a mechanical disturbance to the cells. Transmission electron microscopy images showed that the nanostructures were internalized into the cells within 1 hour of incubation. Cell viability studies showed that the magnetic field and the nanowires separately had minor deleterious effects on the cells; however, when combined, the magnetic field and nanowires caused the cell viability values to drop by up to 39%, depending on the strength of the magnetic field and the concentration of the nanowires. Cell membrane leakage experiments indicated membrane leakage of 20%, suggesting that cell death mechanisms induced by the nanowires and magnetic field involve some cell membrane rupture. Results suggest that magnetic nanowires can kill cancer cells. The proposed process requires simple and low-cost equipment with exposure to only very weak magnetic fields for short time periods. © 2015 Contreras et al.

  10. An induction-based magnetohydrodynamic 3D code for finite magnetic Reynolds number liquid-metal flows in fusion blankets

    International Nuclear Information System (INIS)

    Kawczynski, Charlie; Smolentsev, Sergey; Abdou, Mohamed

    2016-01-01

    Highlights: • A new induction-based magnetohydrodynamic code was developed using a finite difference method. • The code was benchmarked against purely hydrodynamic and MHD flows for low and finite magnetic Reynolds number. • Possible applications of the new code include liquid-metal MHD flows in the breeder blanket during unsteady events in the plasma. - Abstract: Most numerical analysis performed in the past for MHD flows in liquid-metal blankets were based on the assumption of low magnetic Reynolds number and involved numerical codes that utilized electric potential as the main electromagnetic variable. One limitation of this approach is that such codes cannot be applied to truly unsteady processes, for example, MHD flows of liquid-metal breeder/coolant during unsteady events in plasma, such as major plasma disruptions, edge-localized modes and vertical displacements, when changes in plasmas occur at millisecond timescales. Our newly developed code MOONS (Magnetohydrodynamic Object-Oriented Numerical Solver) uses the magnetic field as the main electromagnetic variable to relax the limitations of the low magnetic Reynolds number approximation for more realistic fusion reactor environments. The new code, written in Fortran, implements a 3D finite-difference method and is capable of simulating multi-material domains. The constrained transport method was implemented to evolve the magnetic field in time and assure that the magnetic field remains solenoidal within machine accuracy at every time step. Various verification tests have been performed including purely hydrodynamic flows and MHD flows at low and finite magnetic Reynolds numbers. Test results have demonstrated very good accuracy against known analytic solutions and other numerical data.

  11. An induction-based magnetohydrodynamic 3D code for finite magnetic Reynolds number liquid-metal flows in fusion blankets

    Energy Technology Data Exchange (ETDEWEB)

    Kawczynski, Charlie; Smolentsev, Sergey, E-mail: sergey@fusion.ucla.edu; Abdou, Mohamed

    2016-11-01

    Highlights: • A new induction-based magnetohydrodynamic code was developed using a finite difference method. • The code was benchmarked against purely hydrodynamic and MHD flows for low and finite magnetic Reynolds number. • Possible applications of the new code include liquid-metal MHD flows in the breeder blanket during unsteady events in the plasma. - Abstract: Most numerical analysis performed in the past for MHD flows in liquid-metal blankets were based on the assumption of low magnetic Reynolds number and involved numerical codes that utilized electric potential as the main electromagnetic variable. One limitation of this approach is that such codes cannot be applied to truly unsteady processes, for example, MHD flows of liquid-metal breeder/coolant during unsteady events in plasma, such as major plasma disruptions, edge-localized modes and vertical displacements, when changes in plasmas occur at millisecond timescales. Our newly developed code MOONS (Magnetohydrodynamic Object-Oriented Numerical Solver) uses the magnetic field as the main electromagnetic variable to relax the limitations of the low magnetic Reynolds number approximation for more realistic fusion reactor environments. The new code, written in Fortran, implements a 3D finite-difference method and is capable of simulating multi-material domains. The constrained transport method was implemented to evolve the magnetic field in time and assure that the magnetic field remains solenoidal within machine accuracy at every time step. Various verification tests have been performed including purely hydrodynamic flows and MHD flows at low and finite magnetic Reynolds numbers. Test results have demonstrated very good accuracy against known analytic solutions and other numerical data.

  12. Dirac's æther in curved spacetime-II: the geometric amplification of the cosmic magnetic induction

    Directory of Open Access Journals (Sweden)

    Marcelo Carvalho

    2004-03-01

    Full Text Available We search for an amplification mechanism of the seed cosmic magnetic induction by studying a new version of the Dirac's æther in a curved cosmological background. We find that the variation of the scale factor R(t with cosmic time brings to the magnetic field the desired effect of amplification, that we call geometric amplification.Procuramos por um mecanismo de amplificação das sementes do campo de indução magnética cósmico através do estudo de uma nova versão do æ ther de Dirac em uma arena cosmológica curva. Encontramos uma amplificação que ocorre se o fator de escala R(t varia com o tempo cósmico, acarretando um efeito o qual chamamos de amplificação geométrica do campo magnético.

  13. Mapping the Induction of Magnetic Field Around an Applicator for Dermato Magnetotherapy, using the Magnetic Resonance Method

    Czech Academy of Sciences Publication Activity Database

    Bartušek, Karel; Gescheidtová, E.

    2005-01-01

    Roč. 5, - (2005), s. 62-66 ISSN 1335-8871 R&D Projects: GA AV ČR(CZ) IAA2065201 Keywords : Nuclear Magnetic Resonance * Gradient Echo * Spin Echo Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  14. Integrodifferential model of induction heating of nonmagneticcylindrical billet rotating in uniform magnetic field

    Czech Academy of Sciences Publication Activity Database

    Donátová, M.; Karban, P.; Doležel, Ivo; Ulrych, B.

    2009-01-01

    Roč. 85, č. 4 (2009), s. 16-18 ISSN 0033-2097 R&D Projects: GA ČR(CZ) GA102/07/0496 Institutional research plan: CEZ:AV0Z20570509 Keywords : induction heating * integrodifferential model * electromagnetic field Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.196, year: 2009

  15. Inductively Driven, 3D Liner Compression of a Magnetized Plasma to Megabar Energy Densities

    Energy Technology Data Exchange (ETDEWEB)

    Slough, John [MSNW LLC, Redmond, WA (United States)

    2015-02-01

    To take advantage of the smaller scale, higher density regime of fusion an efficient method for achieving the compressional heating required to reach fusion gain conditions must be found. What is proposed is a more flexible metallic liner compression scheme that minimizes the kinetic energy required to reach fusion. It is believed that it is possible to accomplish this at sub-megajoule energies. This however will require operation at very small scale. To have a realistic hope of inexpensive, repetitive operation, it is essential to have the liner kinetic energy under a megajoule which allows for the survivability of the vacuum and power systems. At small scale the implosion speed must be reasonably fast to maintain the magnetized plasma (FRC) equilibrium during compression. For limited liner kinetic energy, it becomes clear that the thinnest liner imploded to the smallest radius consistent with the requirements for FRC equilibrium lifetime is desired. The proposed work is directed toward accomplishing this goal. Typically an axial (Z) current is employed for liner compression. There are however several advantages to using a θ-pinch coil. With the θ-pinch the liner currents are inductively driven which greatly simplifies the apparatus and vacuum system, and avoids difficulties with the post implosion vacuum integrity. With fractional flux leakage, the foil liner automatically provides for the seed axial compression field. To achieve it with optimal switching techniques, and at an accelerated pace however will require additional funding. This extra expense is well justified as the compression technique that will be enabled by this funding is unique in the ability to implode individual segments of the liner at different times. This is highly advantageous as the liner can be imploded in a manner that maximizes the energy transfer to the FRC. Production of shaped liner implosions for additional axial compression can thus be readily accomplished with the modified power

  16. CFA Films in Amorphous Substrate: Structural Phase Induction and Magnetization Dynamics

    Science.gov (United States)

    Correa, M. A.; Bohn, F.; Escobar, V. M.

    We report a systematic study of the structural and quasi-static magnetic properties, as well as of the dynamic magnetic response through MI effect, in Co2FeAl and MgO//Co2FeAl single layers and a MgO//Co2FeAl/Ag/Co2FeAl trilayered film, all grown onto an amorphous substrate. We present a new route to induce the crystalline structure in the Co2FeAl alloy and verify that changes in the structural phase of this material leads to remarkable modifications of the magnetic anisotropy and, consequently, dynamic magnetic behavior. Considering the electrical and magnetic properties of the Co2FeAl, our results open new possibilities for technological applications of this full-Heusler alloy in rigid and flexible spintronic devices.

  17. Punching influence on magnetic properties of the stator teeth of an induction motor

    International Nuclear Information System (INIS)

    Kedous-Lebouc, A.; Cornut, B.; Perrier, J.C.; Manfe, Ph.; Chevalier, Th.

    2003-01-01

    In order to study the effects of punching of electrical steel sheets, a suitable geometrical structure able to characterize the stator teeth behavior of an induction motor is proposed and validated. The influence of the punching on a fully processed M330-65A is then characterized. A spectacular degradation of loss and B(H) curves is observed. This leads to a perceptible increase of the no-load machine current

  18. Scientific results from the deepened Lopra-1 borehole, Faroe Islands: Magnetic logs from the Lopra-1/1A and Vestmanna-1 wells, Faroe Islands

    Directory of Open Access Journals (Sweden)

    Waagstein, Regin

    2006-07-01

    Full Text Available Susceptibility measurements from cores (representing basalt, lapilli-tuffs and tuffs and magnetic logs from the Lopra-1/1A well are presented. The basalts fall into high- and low-susceptibility groups with no overlap. The high-susceptibility basalts (seven cores have susceptibilities between 4 and 88 ×10–3 SI and consist of basalt with < 1% vesicles from thick massive units. The low-susceptibility basalts are intergranular, intersertal or hypocrystalline and contain no or very little (< 1% visible magnetite, are generally more altered than the high-susceptibility basalts and have susceptibilities in the range from 0.6 to 1.4 × 10–3 SI (seven cores. The susceptibility of ten volcaniclastites of lapilli-tuff or tuff varies from 0.4 to 3.8 × 10–3 SI. The cores from the Lopra-1/1A well reveal a bimodal distribution of magnetic susceptibility. Low susceptibilities ranging from 0.4 to 4 are characteristic of altered basalts poor in magnetite, lapilli-tuffs and tuffs. Thus single measurements of susceptibility are of little use indiscriminating between these three types of rock. Susceptibility logs from the Lopra-1/1A well show that the variation below 3315 m distinguishes clearly between volcaniclastics (hyaloclastites with low and fairly constant susceptibility and basalt beds of between 5 and 10 m thickness (with high susceptibility. The volcaniclastics comprise some 60–70% of the sequence between 3315 and 3515 m with the maximum continuous sediment layer being 80 m thick. A 1½ m core of solid basalt at 2381 m and sidewall cores of basalt from the Lopra-1/1A well have a mean susceptibility of 22.1 ± 3.5 × 10–3 SI (standard deviation (σ = 23.6, number of samples (N = 46, while samples of hyaloclastite (lapilli-tuff and tuff have a mean susceptibility of0.85 × 10–3 SI (σ = 0.39, N = 17.The mean values of the rock magnetic parameters for 303 basalt plugs from the Vestmanna-1 well are: Qave = 13.3 ± 0.6 (σ = 11, Save = 11.8 ± 0

  19. Magnetic induction heating of superparamagnetic nanoparticles during rewarming augments the recovery of hUCM-MSCs cryopreserved by vitrification.

    Science.gov (United States)

    Wang, Jianye; Zhao, Gang; Zhang, Zhengliang; Xu, Xiaoliang; He, Xiaoming

    2016-03-01

    Cryopreservation by vitrification has been recognized as a promising strategy for long-term banking of living cells. However, the difficulty to generate a fast enough heating rate to minimize devitrification and recrystallization-induced intracellular ice formation during rewarming is one of the major obstacles to successful vitrification. We propose to overcome this hurdle by utilizing magnetic induction heating (MIH) of magnetic nanoparticles to enhance rewarming. In this study, superparamagnetic (SPM) Fe3O4 nanoparticles were synthesized by a chemical coprecipitation method. We successfully applied the MIH of Fe3O4 nanoparticles for rewarming human umbilical cord matrix mesenchymal stem cells (hUCM-MSCs) cryopreserved by vitrification. Our results show that extracellular Fe3O4 nanoparticles with MIH may efficiently suppress devitrification and/or recrystallization during rewarming and significantly improve the survival of vitrified cells. We further optimized the concentration of Fe3O4 nanoparticles and the current of an alternating current (AC) magnetic field for generating the MIH to maximize cell viability. Our results indicate that MIH in an AC magnetic field with 0.05% (w/v) Fe3O4 nanoparticles significantly facilitates rewarming and improves the cryopreservation outcome of hUCM-MSCs by vitrification. The application of MIH of SPM nanoparticles to achieve rapid and spatially homogeneous heating is a promising strategy for enhanced cryopreservation of stem cells by vitrification. Here we report the successful synthesis and application of Fe3O4 nanoparticles for magnetic induction heating (MIH) to enhance rewarming of vitrification-cryopreserved human umbilical cord matrix mesenchymal stem cells (hUCM-MSCs). We found that MIH-enhanced rewarming greatly improves the survival of vitrification-cryopreserved hUCM-MSCs. Moreover, the hUCM-MSCs retain their intact stemness and multilineage potential of differentiation post cryopreservation by vitrification with the

  20. Numerical modeling of magnetic induction and heating in injection molding tools

    DEFF Research Database (Denmark)

    Guerrier, Patrick; Hattel, Jesper Henri

    2013-01-01

    the temperatures as close as possible to the cavity surface, by means of an integrated induction heating system in the injection molding tool, to improve the fluidity of the polymer melt hereby ensuring that the polymer melt will continue to flow until the mold cavity is completely filled. The presented work uses......Injection molding of parts with special requirements or features such as micro- or nanostructures on the surface, a good surface finish, or long and thin features results in the need of a specialized technique to ensure proper filling and acceptable cycle time. The aim of this study is to increase...

  1. Contactless remote induction of shear waves in soft tissues using a transcranial magnetic stimulation device

    International Nuclear Information System (INIS)

    Grasland-Mongrain, Pol; Miller-Jolicoeur, Erika; Cloutier, Guy; Tang, An; Catheline, Stefan

    2016-01-01

    This study presents the first observation of shear waves induced remotely within soft tissues. It was performed through the combination of a transcranial magnetic stimulation device and a permanent magnet. A physical model based on Maxwell and Navier equations was developed. Experiments were performed on a cryogel phantom and a chicken breast sample. Using an ultrafast ultrasound scanner, shear waves of respective amplitudes of 5 and 0.5 μm were observed. Experimental and numerical results were in good agreement. This study constitutes the framework of an alternative shear wave elastography method. (paper)

  2. Contactless remote induction of shear waves in soft tissues using a transcranial magnetic stimulation device

    Science.gov (United States)

    Grasland-Mongrain, Pol; Miller-Jolicoeur, Erika; Tang, An; Catheline, Stefan; Cloutier, Guy

    2016-03-01

    This study presents the first observation of shear waves induced remotely within soft tissues. It was performed through the combination of a transcranial magnetic stimulation device and a permanent magnet. A physical model based on Maxwell and Navier equations was developed. Experiments were performed on a cryogel phantom and a chicken breast sample. Using an ultrafast ultrasound scanner, shear waves of respective amplitudes of 5 and 0.5 μm were observed. Experimental and numerical results were in good agreement. This study constitutes the framework of an alternative shear wave elastography method.

  3. Specific features of well logging of boreholes drilled on electrical nonconducting solutions

    International Nuclear Information System (INIS)

    Ruchkin, A.F.; Fomenko, V.G.

    1978-01-01

    Methods for identification of permeable strata and determination of their porosity and oil-gas saturation using standard combination of geophysical investigations in the boreholes drilled with nonaqueous and inert drilling fluids are considered. Geophysical combination consists of the methods indications of which are independent on electrical conductivity of drilling fluids. They are all modifications of radioactivity logging (gamma logging, neutron logging, neutron-gamma logging, gamma-gamma logging, pulsed neutron logging, nuclear-magnetic logging), acoustic logging and thermal logging

  4. Use of Propofol for Induction and Maintenance of Anesthesia in a King Penguin ( Aptenodytes patagonicus ) Undergoing Magnetic Resonance Imaging.

    Science.gov (United States)

    Bigby, Sarah E; Carter, Jennifer E; Bauquier, Sébastien; Beths, Thierry

    2016-09-01

    Anesthesia protocols for patients with intracranial lesions need to provide hemodynamic stability, preserve cerebrovascular autoregulation, avoid increases in intracranial pressure, and facilitate a rapid recovery. Propofol total intravenous anesthesia (TIVA) maintains cerebral blood flow autoregulation and is considered superior to inhalant agents as an anesthetic protocol for patients with intracranial lesions. A propofol-based TIVA subsequent to premedication with medetomidine and diazepam was used in a king penguin ( Aptenodytes patagonicus ) undergoing magnetic resonance imaging of the brain after a new onset of seizures. This protocol provided a rapid and smooth induction and calm recovery in the penguin. When ventilation control is possible, propofol TIVA may be a superior choice to inhalant agents for anesthesia of birds with potential intracranial lesions.

  5. The Distribution of Cloud to Ground Lightning Strike Intensities and Associated Magnetic Inductance Fields Near the Kennedy Space Center

    Science.gov (United States)

    Burns, Lee; Decker, Ryan

    2005-01-01

    Lightning strike location and peak current are monitored operationally in the Kennedy Space Center (KSC) Cape Canaveral Air Force Station (CCAFS) area by the Cloud to Ground Lightning Surveillance System (CGLSS). The present study compiles ten years worth of CGLSS data into a database of near strikes. Using shuffle launch platform LP39A as a convenient central point, all strikes recorded within a 20-mile radius for the period of record O R ) from January 1, 1993 to December 31,2002 were included in the subset database. Histograms and cumulative probability curves are produced for both strike intensity (peak current, in kA) and the corresponding magnetic inductance fields (in A/m). Results for the full POR have application to launch operations lightning monitoring and post-strike test procedures.

  6. A technical note about Phidel: A new software for evaluating magnetic induction field generated by power lines

    International Nuclear Information System (INIS)

    Comelli, M.; Benes, M.; Bampo, A.; Villalta, R.

    2007-01-01

    The Regional Environment Protection Agency of Friuli Venezia Giulia (ARPA FVG, Italy) has performed an analysis on existing software designed to calculate magnetic induction field generated by power lines. As far as the agency's requirements are concerned the tested programs display some difficulties in the immediate processing of electrical and geometrical data supplied by plant owners, and in certain cases turn out to be inadequate in representing complex configurations of power lines. Phidel, an innovative software, tackles and works out all the above-mentioned problems. Therefore, the obtained results, when compared with those of other programs, are the closest to experimental measurements. The output data can be employed both in the GIS and Excel environments, allowing the immediate overlaying of digital cartography and the determining of the 3 and 10 μT bands, in compliance with the Italian Decree of the President of the Council of Ministers of 8 July 2003. (authors)

  7. Validation of methods to measure uranium isotopes using magnetic sector mass spectrometry with inductively coupled plasma source

    International Nuclear Information System (INIS)

    Hernandez M, H.; Rios L, M. J.; Romero G, E. T.

    2017-10-01

    The mass spectrometry technique with inductively coupled plasma source (Icp-Ms) has been widely used to measure isotopic ratios of elements toxic to human health. Reason for which, in this work several measurement methods for the analysis of uranium isotopes in different matrices were implemented using magnetic sector mass spectrometry with inductively coupled plasma source (Icp-SFMS). Groundwater, sediment, soil and urine were the matrices analyzed, which were supplied by intercomparison tests conducted by the IAEA and Association for the Promotion of Quality Control of Medical Biology Analysis in Radio-toxicology. The procedures used in the treatment of soil, sediment and water samples were based on US EPA methods. In the case of the urine sample, the preparation was rapid (1:20 dilution). The average of the results obtained in yield of each matrix was 94, 71, 72 and 78% for water, urine, soil and sediment respectively. In addition, the precision in terms of standard relative deviation was less than 5% and the accuracy was less than 4%. In conclusion, the Icp-SFMS is a very sensitive technique for measuring isotopes of U in different matrices. However, careful tuning is necessary, especially in the mass regions of interest 234, 235 and 238 if an external quantification is considered using natural U solutions. (Author)

  8. Repetitive transcranial magnetic stimulation modulates the impact of a negative mood induction

    NARCIS (Netherlands)

    Möbius, M.; Lacomblé, L.M.T.; Meyer, T.; Schutter, D.J.L.G.; Gielkens, T.; Becker, E.S.; Tendolkar, I.; Eijndhoven, P.F.P. van

    2017-01-01

    High frequency repetitive Transcranial Magnetic Stimulation (rTMS) over the left dorsolateral prefrontal cortex (DLPFC) has been found to alleviate depressive symptoms. However, the mechanisms driving these effects are still poorly understood. In the current study, we tested the idea that this

  9. DESIGN AND APPLICATION OF MAGNETIC BEARING SUSPENSION SYSTEM IN A THREE PHASE INDUCTION MOTOR

    Directory of Open Access Journals (Sweden)

    Osman GÜRDAL

    1998-03-01

    Full Text Available The current popularity of suspension and levitation stems no doubt the possibilities in high-speed ground transportation schemes. Although these are both challenging and exciting, there is considerable scope for application of suspension techniques to achieving frictionless bearing. The requirement in this case is often for close tolerances, low power consumption, small airgaps and ingeneral, compactness. Thus, magnetic suspension using DC electromagnets schemes have received more attention than the other techniques of repulsion levitation. Proposed prototype system consists of a conventional stator and its rotor without iron core, set of electromagnets for suspension of rotor shaft and set of compensation circuits feedbacked by optical-transducers. Prototyped system is aimed as a laboratory demonstration tool so there is no challenging to exceed the speeds of 1500 rev/min that is the speed of motor with mechanical bearings. Magnetic bearing suspension system provides a high impact visual demonstration of many principles in undergraduate educational programs in electrical education, e.g., electromagnetic design, PD controlled compensation of a unstable control system and power amplifier design. The system is capable of giving a good comparison between mechanical and magnetic bearing up to speeds 350 rev/min. Power losses without load show about 15% reduction with magnetic bearing. The noise of the motor is also decreased to a low level.

  10. Diagnostics of an rf induction plasma torch with the aid of a magnetic probe

    International Nuclear Information System (INIS)

    Shamim, A.; Wooding, E.R.

    1978-01-01

    Estimates of a plasma temperature, electrical conductivity, and torch efficiency have been made from simple measurements made on the plasma and on the rf supply. Measurements were made with the aid of a simple magnetic probe and a pickup coil. Estimates are also made of the heating-coil constants

  11. Magnetic Shear and Transport in ECRH Discharges of the TJ-II under Ohmic Induction

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Bruna, D.; Castejon, F.; Romero, J. A.; Estrada, T.; Medina, F.; Ochando, M.; Lopez-Fraguas, A.; Ascasibar, E.; Herranz, J.; Sanchez, E.; Luna, E. de la; Pastor, I.

    2006-07-01

    TJ-II is ha heliac type stellarator characterised by high, but almost constant, vacuum rotational transform throughout the confining volume. In ECRH plasmas, moderate induced ohmic currents (negligible heating and modification of the magnetic field nodules) are enough to disregard the bootstrap contribution, which allows us performing a fair calculation of the evolution of the rotational transform. We use the loop voltage diagnostic to estimate the plasma electrical conductivity. Then the evolution of the rotational transform and shear is related to changes in the profiles of electron and thermal diffusivities: negative shear correlates with decreasing diffusivities in the region of steepest density gradient; transport increases toward zero shear but the achieved positive values are too small to draw conclusions. The radial sweeping of lowest order rational magnetic surfaces does not determine the observed trends in transport. (Author)43 refs.

  12. Magnetic Shear and Transport in ECRH Discharges of the TJ-II under Ohmic Induction

    International Nuclear Information System (INIS)

    Lopez-Bruna, D.; Castejon, F.; Romero, J. A.; Estrada, T.; Medina, F.; Ochando, M.; Lopez-Fraguas, A.; Ascasibar, E.; Herranz, J.; Sanchez, E.; Luna, E. de la; Pastor, I.

    2006-01-01

    TJ-II is ha heliac type stellarator characterised by high, but almost constant, vacuum rotational transform throughout the confining volume. In ECRH plasmas, moderate induced ohmic currents (negligible heating and modification of the magnetic field nodules) are enough to disregard the bootstrap contribution, which allows us performing a fair calculation of the evolution of the rotational transform. We use the loop voltage diagnostic to estimate the plasma electrical conductivity. Then the evolution of the rotational transform and shear is related to changes in the profiles of electron and thermal diffusivities: negative shear correlates with decreasing diffusivities in the region of steepest density gradient; transport increases toward zero shear but the achieved positive values are too small to draw conclusions. The radial sweeping of lowest order rational magnetic surfaces does not determine the observed trends in transport. (Author)43 refs

  13. Finite-Element 2-D Model of Induction Heating of Rotating Billets in System of Permanent Magnets and its Experimental Verification

    Czech Academy of Sciences Publication Activity Database

    Mach, F.; Štarman, V.; Karban, P.; Doležel, Ivo; Kůs, P.

    2014-01-01

    Roč. 61, č. 5 (2014), s. 2584-2591 ISSN 0278-0046 R&D Projects: GA ČR(CZ) GAP102/11/0498 Institutional support: RVO:61388998 Keywords : higher order finite-element method * induction heating * magnetic field Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 6.498, year: 2014

  14. Magnetic inductive heating of organs of mouse models treated by copolymer coated Fe3O4 nanoparticles

    Science.gov (United States)

    Pham, Hong Nam; Giang Pham, Thi Ha; Nguyen, Dac Tu; Thong Phan, Quoc; Thu Huong Le, Thi; Thu Ha, Phuong; Do, Hung Manh; Nhung Hoang, Thi My; Phuc Nguyen, Xuan

    2017-06-01

    Biodistribution studies provide basic information to design and perform various applications of superparamagnetic iron oxide magnetic nanoparticles (SPIOs) in biomedicine such as drug delivery, MRI as well as hyperthermia. Recently, several quantitative measurements as well as new imaging methods have been used to characterize the SPIOs distribution in organs and in tissues of animal model. In this report we used the fabricated iron oxide nanoparticles coated with two block copolymers of polystyrene-co-polyacrylic acid (St-co-PAA) and polylactic acid-co-polyethylene glycol (PLA-PEG). The biodistributions were investigated ex-vivo for several organs of both healthy and Sarcoma transplanted Swiss mice. The SPIOs concentrations were verified mainly by magnetic inductive heating (MIH) measurement with a combination with atomic absorption spectroscopy (AAS). The results indicated the density detected highest in liver and lowest in kidney. The SPIOs concentration increased significantly up to 24 h after the injection. The observations by our two methods not only are in agreement with each other but also consistent with the tendency reported by other techniques. Discussion will also concern injection strategy for various aspects of hyperthermia applications. Invited talk at 8th Int. Workshop on Advanced Materials Science and Nanotechnology (Ha Long City, Vietnam, 8-12 November 2016).

  15. Isotopic ratio measurement using a double focusing magnetic sector mass analyser with an inductively coupled plasma as an ion source

    International Nuclear Information System (INIS)

    Walder, A.J.; Freedman, P.A.

    1992-01-01

    An inductively coupled plasma source was coupled to a magnetic sector mass analyser equipped with seven Faraday detectors. An electrostatic filter located between the plasma source and the magnetic sector was used to create a double focusing system. Isotopic ratio measurements of uranium and lead standards revealed levels of internal and external precision comparable to those obtained using thermal inonization mass spectrometry. An external precision of 0.014% was obtained from the 235 U: 238 U measurement of six samples of a National Bureau of Standards (NBS) Standard Reference Material (SRM) U-500, while an RSD of 0.022% was obtained from the 206 Pb: 204 Pb measurement of six samples of NBS SRM Pb-981. Measured isotopic ratios deviated from the NBS value by approximately 0.9% per atomic mass unit. This deviation approximates to a linear function of mass bias and can therefore be corrected for by the analysis of standards. The analysis of NBS SRM Sr-987 revealed superior levels of internal and external precision. The normalization of the 87 Sr: 86 Sr ratio to the 86 Sr: 88 Sr ratio reduced the RSD to approximately 0.008%. The measured ratio was within 0.01% of the NBS value and the day-to-day reproducibility was consistent within one standard deviation. (author)

  16. RF power absorption by plasma of low pressure low power inductive discharge located in the external magnetic field

    Science.gov (United States)

    Kralkina, E. A.; Rukhadze, A. A.; Nekliudova, P. A.; Pavlov, V. B.; Petrov, A. K.; Vavilin, K. V.

    2018-03-01

    Present paper is aimed to reveal experimentally and theoretically the influence of magnetic field strength, antenna shape, pressure, operating frequency and geometrical size of plasma sources on the ability of plasma to absorb the RF power characterized by the equivalent plasma resistance for the case of low pressure RF inductive discharge located in the external magnetic field. The distinguishing feature of the present paper is the consideration of the antennas that generate not only current but charge on the external surface of plasma sources. It is shown that in the limited plasma source two linked waves can be excited. In case of antennas generating only azimuthal current the waves can be attributed as helicon and TG waves. In the case of an antenna with the longitudinal current there is a surface charge on the side surface of the plasma source, which gives rise to a significant increase of the longitudinal and radial components of the RF electric field as compared with the case of the azimuthal antenna current.

  17. Microstructure and magnetism of Co2FeAl Heusler alloy prepared by arc and induction melting compared with planar flow casting

    Science.gov (United States)

    Titov, A.; Jiraskova, Y.; Zivotsky, O.; Bursik, J.; Janickovic, D.

    2018-04-01

    This paper is devoted to investigations of the structural and magnetic properties of the Co2FeAl Heusler alloy produced by three technologies. The alloys prepared by arc and induction melting have resulted in coarse-grained samples in contrast to the fine-grained ribbon-type sample prepared by planar flow casting. Scanning electron microscopy completed by energy dispersive X-ray spectroscopy, X-ray diffraction, Mössbauer spectroscopy, and magnetic methods sensitive to both bulk and surface were applied. The chemical composition was slightly different from the nominal only for the ribbon sample. From the viewpoint of magnetic properties, the bulk coercivity and remnant magnetization have followed the structure influenced by the technology used. Saturation magnetization was practically the same for samples prepared by arc and induction melting, whereas the magnetization of ribbon is slightly lower due to a higher Al content at the expense of iron and cobalt. The surface magnetic properties were markedly influenced by anisotropy, grain size, and surface roughness of the samples. The surface roughness and brittleness of the ribbon-type sample did not make domain structure observation possible. The other two samples could be well polished and their highly smooth surface has enabled domain structure visualization by both magneto-optical Kerr microscopy and magnetic force microscopy.

  18. Development of a simple proton nuclear magnetic resonance-based procedure to estimate the approximate distribution coefficient at physiological pH (logD7.4)

    DEFF Research Database (Denmark)

    Stéen, E Johanna L; Nyberg, Nils; Lehel, Szabolcs

    2017-01-01

    D7.4) in 1-octanol and D2O buffer. The method can be applied to both UV and non-UV active compounds. In addition, neither calibration curves nor internal/external standards are needed. We have demonstrated that logD7.4 can be accurately measured using 1H NMR for compounds within the logD7.4 interval...

  19. Encyclopedia of well logging

    International Nuclear Information System (INIS)

    Desbrandes, R.

    1985-01-01

    The 16 chapters of this book aim to provide students, trainees and engineers with a manual covering all well-logging measurements ranging from drilling to productions, from oil to minerals going by way of geothermal energy. Each chapter is a summary but a bibliography is given at the end of each chapter. Well-logging during drilling, wireline logging equipment and techniques, petroleum logging, data processing of borehole data, interpretation of well-logging, sampling tools, completion and production logging, logging in relief wells to kill off uncontrolled blowouts, techniques for high temperature geothermal energy, small-scale mining and hydrology, logging with oil-base mud and finally recommended logging programs are all topics covered. There is one chapter on nuclear well-logging which is indexed separately. (UK)

  20. Innovative mutually inductively coupled radiofrequency coils for magnetic resonance imaging and spectroscopy

    International Nuclear Information System (INIS)

    Tomanek, B.

    2006-01-01

    The paper presents the author's thesis based on the work carried out at the Institute for Bio diagnostics in Canada and published in years 2000-2006. A patented new generation of the RF coils were introduced to MRI and MRS techniques what significantly reduced SNR and improved image resolution of MR diagnostic procedure. Examples of the applications of the RF coils are presented. The intraoperative MRI system with a movable magnet used during the brain surgery included RF probe. This coil was efficiently used for breast screening and detection of submillimeter tumors. Quantification of the tissue metabolites by combining MRT with 31 P MRS can be achieved using dual - frequency RF coils. It was successfully tested on a rat liver. The innovative RF coil design was supported by the theoretical analysis and performed experiments. As an extension of the design an idea and the theory construction of multi - frequency multi - ring coil and its possible applications are also considered

  1. Designing an optimum pulsed magnetic field by a resistance/self-inductance/capacitance discharge system and alignment of carbon nanotubes embedded in polypyrrole matrix

    Science.gov (United States)

    Kazemikia, Kaveh; Bonabi, Fahimeh; Asadpoorchallo, Ali; Shokrzadeh, Majid

    2015-02-01

    In this work, an optimized pulsed magnetic field production apparatus is designed based on a RLC (Resistance/Self-inductance/Capacitance) discharge circuit. An algorithm for designing an optimum magnetic coil is presented. The coil is designed to work at room temperature. With a minor physical reinforcement, the magnetic flux density can be set up to 12 Tesla with 2 ms duration time. In our design process, the magnitude and the length of the magnetic pulse are the desired parameters. The magnetic field magnitude in the RLC circuit is maximized on the basis of the optimal design of the coil. The variables which are used in the optimization process are wire diameter and the number of coil layers. The coil design ensures the critically damped response of the RLC circuit. The electrical, mechanical, and thermal constraints are applied to the design process. A locus of probable magnetic flux density values versus wire diameter and coil layer is provided to locate the optimum coil parameters. Another locus of magnetic flux density values versus capacitance and initial voltage of the RLC circuit is extracted to locate the optimum circuit parameters. Finally, the application of high magnetic fields on carbon nanotube-PolyPyrrole (CNT-PPy) nano-composite is presented. Scanning probe microscopy technique is used to observe the orientation of CNTs after exposure to a magnetic field. The result shows alignment of CNTs in a 10.3 Tesla, 1.5 ms magnetic pulse.

  2. Chronic treatment with repetitive transcranial magnetic stimulation inhibits seizure induction by electroconvulsive shock in rats.

    Science.gov (United States)

    Fleischmann, A; Hirschmann, S; Dolberg, O T; Dannon, P N; Grunhaus, L

    1999-03-15

    Studies in laboratory animals suggest that repetitive transcranial magnetic stimulation (rTMS) and electroconvulsive shock (ECS) increase seizure inhibition acutely. This study was designed to explore whether chronic rTMS would also have seizure inhibition properties. To this purpose we administered rTMS (Magstim Rapid) and sham rTMS twice daily (2.5 T, 4-sec train duration, 20 Hz) to two groups of 10 rats for 16 days. The rTMS coil was a 50-mm figure-8 coil held directly over the rat's head. Raters were blind to experimental groups. On days 11, 17, and 21 (5 days after the last rTMS) ECS was administered with a Siemens convulsator using three electrical charge levels. Variables examined were the presence or absence of seizures and seizure length (measured from the initiation of the tonic contraction until the end of the limb movement). At day 11 rTMS had no effect on seizures, and both rTMS and sham rTMS animals convulsed equally. At day 17, however, rTMS-treated animals convulsed significantly less (both at presence/absence of seizures, and at seizure length) than sham rTMS animals. At day 21 the effects of rTMS had disappeared. These findings suggest that rTMS administered chronically leads to changes in seizure threshold similar to those reported for ECS and ECT; however, these effects were short-lived.

  3. Geophysical log analysis of selected test and residential wells at the Shenandoah Road National Superfund Site, East Fishkill, Dutchess County, New York

    Science.gov (United States)

    Reynolds, Richard J.; Anderson, J. Alton; Williams, John H.

    2015-01-01

    The U.S. Geological Survey collected and analyzed geophysical logs from 20 test wells and 23 residential wells at the Shenandoah Road National Superfund Site in East Fishkill, New York, from 2006 through 2010 as part of an Interagency Agreement to provide hydrogeologic technical support to the U.S. Environmental Protection Agency, Region 2. The geophysical logs collected include caliper, gamma, acoustic and optical televiewer, deviation, electromagnetic-induction, magnetic-susceptibility, fluid-property, and flow under ambient and pumped conditions. The geophysical logs were analyzed along with single-well aquifer test data and drilling logs to characterize the lithology, fabric, fractures, and flow zones penetrated by the wells. The results of the geophysical log analysis were used as part of the hydrogeologic characterization of the site and in the design of discrete-zone monitoring installations in the test wells and selected residential wells.

  4. Non-contact multi-frequency magnetic induction spectroscopy system for industrial-scale bio-impedance measurement

    International Nuclear Information System (INIS)

    O'Toole, M D; Marsh, L A; Davidson, J L; Tan, Y M; Armitage, D W; Peyton, A J

    2015-01-01

    Biological tissues have a complex impedance, or bio-impedance, profile which changes with respect to frequency. This is caused by dispersion mechanisms which govern how the electromagnetic field interacts with the tissue at the cellular and molecular level. Measuring the bio-impedance spectra of a biological sample can potentially provide insight into the sample’s properties and its cellular structure. This has obvious applications in the medical, pharmaceutical and food-based industrial domains. However, measuring the bio-impedance spectra non-destructively and in a way which is practical at an industrial scale presents substantial challenges. The low conductivity of the sample requires a highly sensitive instrument, while the demands of industrial-scale operation require a fast high-throughput sensor of rugged design. In this paper, we describe a multi-frequency magnetic induction spectroscopy (MIS) system suitable for industrial-scale, non-contact, spectroscopic bio-impedance measurement over a bandwidth of 156 kHz–2.5 MHz. The system sensitivity and performance are investigated using calibration and known reference samples. It is shown to yield rapid and consistently sensitive results with good long-term stability. The system is then used to obtain conductivity spectra of a number of biological test samples, including yeast suspensions of varying concentration and a range of agricultural produce, such as apples, pears, nectarines, kiwis, potatoes, oranges and tomatoes. (paper)

  5. Ion diode performance on a positive polarity inductive voltage adder with layered magnetically insulated transmission line flow

    International Nuclear Information System (INIS)

    Hinshelwood, D. D.; Schumer, J. W.; Allen, R. J.; Commisso, R. J.; Jackson, S. L.; Murphy, D. P.; Phipps, D.; Swanekamp, S. B.; Weber, B. V.; Ottinger, P. F.; Apruzese, J. P.; Cooperstein, G.; Young, F. C.

    2011-01-01

    A pinch-reflex ion diode is fielded on the pulsed-power machine Mercury (R. J. Allen, et al., 15th IEEE Intl. Pulsed Power Conf., Monterey, CA, 2005, p. 339), which has an inductive voltage adder (IVA) architecture and a magnetically insulated transmission line (MITL). Mercury is operated in positive polarity resulting in layered MITL flow as emitted electrons are born at a different potential in each of the adder cavities. The usual method for estimating the voltage by measuring the bound current in the cathode and anode of the MITL is not accurate with layered flow, and the interaction of the MITL flow with a pinched-beam ion diode load has not been studied previously. Other methods for determining the diode voltage are applied, ion diode performance is experimentally characterized and evaluated, and circuit and particle-in-cell (PIC) simulations are performed. Results indicate that the ion diode couples efficiently to the machine operating at a diode voltage of about 3.5 MV and a total current of about 325 kA, with an ion current of about 70 kA of which about 60 kA is proton current. It is also found that the layered flow impedance of the MITL is about half the vacuum impedance.

  6. Investigating the Relationship between Cerebrospinal Fluid and Magnetic Induction Phase Shift in Rabbit Intracerebral hematoma expansion Monitoring by MRI.

    Science.gov (United States)

    Chen, Mingsheng; Yan, Qingguang; Sun, Jian; Jin, Gui; Qin, Mingxin

    2017-09-11

    In a prior study of intracerebral hemorrhage monitoring using magnetic induction phase shift (MIPS), we found that MIPS signal changes occurred prior to those seen with intracranial pressure. However, the characteristic MIPS alert is not yet fully explained. Combining the brain physiology and MIPS theory, we propose that cerebrospinal fluid (CSF) may be the primary factor that leads to hematoma expansion being alerted by MIPS earlier than with intracranial pressure monitoring. This paper investigates the relationship between CSF and MIPS in monitoring of rabbit intracerebral hemorrhage models, which is based on the MIPS measurements data, the quantified data on CSF from medical images and the amount of injected blood in the rabbit intracerebral hemorrhage model. In the investigated results, a R value of 0.792 with a significance of 0.019 is observed between the MIPS and CSF, which is closer than MIPS and injected blood. Before the reversal point of MIPS, CSF is the leading factor in MIPS signal changing in an early hematoma expansion stage. Under CSF compensation, CSF reduction compensates for hematoma expansion in the brain to keep intracranial pressure stable. MIPS decrease results from the reducing CSF volume. This enables MIPS to detect hematoma expansion earlier than intracranial pressure.

  7. A Combined Chemical and Magneto-Mechanical Induction of Cancer Cell Death by the Use of Functionalized Magnetic Iron Nanowires

    KAUST Repository

    Martinez Banderas, Aldo

    2016-04-01

    Cancer prevails as one of the most devastating diseases being at the top of death causes for adults despite continuous development and innovation in cancer therapy. Nanotechnology may be used to achieve therapeutic dosing, establish sustained-release drug profiles, and increase the half-life of drugs. In this context, magnetic nanowires (NWs) have shown a good biocompatibility and cellular internalization with a low cytotoxic effect. In this thesis, I induced cancer cell death by combining the chemotherapeutic effect of iron NWs functionalized with Doxorubicin (DOX) with mechanical disturbance under a low frequency alternating magnetic field. Two different agents, APTES and BSA, were separately used for coating NWs permitting further functionalization with DOX. Internalization was qualitatively and quantitatively assessed for both formulations by confocal reflection microscopy and inductively coupled plasma-mass spectrometry. From confocal reflection analysis, BSA formulations demonstrate to have a higher internalization degree and a broader distribution within the cells in comparison to APTES formulations. Both groups of functionalized NWs generated a comparable cytotoxic effect in MDA-MB-231 breast cancer cells in a DOX concentration-dependent manner, (~60% at the highest concentration tested) that was significantly different from the effect produced by the free DOX (~95% at the same concentration) and non-functionalized NWs formulations (~10% at the same NWs concentration). A synergistic cytotoxic effect is obtained when a low frequency magnetic field (1 mT, 10 Hz) is applied to cells treated with the two formulations that is again comparable (~70% at the highest concentration). Furthermore, the cytotoxic effect of both groups of coated NWs without the drug increased notoriously when the field is applied (~25% at the highest concentration tested). Here, a novel bimodal method for cancer cell destruction was developed by the conjugation of the magneto

  8. http Log Analysis

    DEFF Research Database (Denmark)

    Bøving, Kristian Billeskov; Simonsen, Jesper

    2004-01-01

    This article documents how log analysis can inform qualitative studies concerning the usage of web-based information systems (WIS). No prior research has used http log files as data to study collaboration between multiple users in organisational settings. We investigate how to perform http log...... analysis; what http log analysis says about the nature of collaborative WIS use; and how results from http log analysis may support other data collection methods such as surveys, interviews, and observation. The analysis of log files initially lends itself to research designs, which serve to test...... hypotheses using a quantitative methodology. We show that http log analysis can also be valuable in qualitative research such as case studies. The results from http log analysis can be triangulated with other data sources and for example serve as a means of supporting the interpretation of interview data...

  9. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    Operation of the magnet has gone quite smoothly during the first half of this year. The magnet has been at 4.5K for the full period since January. There was an unplanned short stop due to the CERN-wide power outage on May 28th, which caused a slow dump of the magnet. Since this occurred just before a planned technical stop of the LHC, during which access in the experimental cavern was authorized, it was decided to leave the magnet OFF until 2nd June, when magnet was ramped up again to 3.8T. The magnet system experienced a fault also resulting in a slow dump on April 14th. This was triggered by a thermostat on a filter choke in the 20kA DC power converter. The threshold of this thermostat is 65°C. However, no variation in the water-cooling flow rate or temperature was observed. Vibration may have been the root cause of the fault. All the thermostats have been checked, together with the cables, connectors and the read out card. The tightening of the inductance fixations has also been checked. More tem...

  10. Log N-log S in inconclusive

    Science.gov (United States)

    Klebesadel, R. W.; Fenimore, E. E.; Laros, J.

    1983-01-01

    The log N-log S data acquired by the Pioneer Venus Orbiter Gamma Burst Detector (PVO) are presented and compared to similar data from the Soviet KONUS experiment. Although the PVO data are consistent with and suggestive of a -3/2 power law distribution, the results are not adequate at this state of observations to differentiate between a -3/2 and a -1 power law slope.

  11. The Meaning of Logs

    NARCIS (Netherlands)

    Etalle, Sandro; Massacci, Fabio; Yautsiukhin, Artsiom

    2007-01-01

    While logging events is becoming increasingly common in computing, in communication and in collaborative work, log systems need to satisfy increasingly challenging (if not conflicting) requirements.Despite the growing pervasiveness of log systems, to date there is no high-level framework which

  12. The Meaning of Logs

    NARCIS (Netherlands)

    Etalle, Sandro; Massacci, Fabio; Yautsiukhin, Artsiom; Lambrinoudakis, Costas; Pernul, Günther; Tjoa, A Min

    While logging events is becoming increasingly common in computing, in communication and in collaborative environments, log systems need to satisfy increasingly challenging (if not conflicting) requirements. In this paper we propose a high-level framework for modeling log systems, and reasoning about

  13. Detection of Static Eccentricity Fault in Saturated Induction Motors by Air-Gap Magnetic Flux Signature Analysis Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    N. Halem

    2013-06-01

    Full Text Available Unfortunately, motor current signature analysis (MCSA cannot detect the small degrees of the purely static eccentricity (SE defects, while the air-gap magnetic flux signature analysis (FSA is applied successfully. The simulation results are obtained by using time stepping finite elements (TSFE method. In order to show the impact of magnetic saturation upon the diagnosis of SE fault, the analysis is carried out for saturated induction motors. The index signatures of static eccentricity fault around fundamental and PSHs are detected successfully for saturated motor.

  14. DETECTION OF STATIC ECCENTRICITY FAULT IN SATURATED INDUCTION MOTORS BY AIR-GAP MAGNETIC FLUX SIGNATURE ANALYSIS USING FINITE ELEMENT METHOD

    Directory of Open Access Journals (Sweden)

    N. Halem

    2013-06-01

    Full Text Available Unfortunately, motor current signature analysis (MCSA cannot detect the small degrees of the purely static eccentricity (SE defects, while the air-gap magnetic flux signature analysis (FSA is applied successfully. The simulation results are obtained by using time stepping finite elements (TSFE method. In order to show the impact of magnetic saturation upon the diagnosis of SE fault, the analysis is carried out for saturated induction motors. The index signatures of static eccentricity fault around fundamental and PSHs are detected successfully for saturated motor.

  15. DETECTION OF STATIC ECCENTRICITY FAULT IN SATURATED INDUCTION MOTORS BY AIR-GAP MAGNETIC FLUX SIGNATURE ANALYSIS USING FINITE ELEMENT METHOD

    Directory of Open Access Journals (Sweden)

    N. Halem

    2015-07-01

    Full Text Available Unfortunately, motor current signature analysis (MCSA cannot detect the small degrees of the purely static eccentricity (SE defects, while the air-gap magnetic flux signature analysis (FSA is applied successfully. The simulation results are obtained by using time stepping finite elements (TSFE method. In order to show the impact of magnetic saturation upon the diagnosis of SE fault, the analysis is carried out for saturated induction motors. The index signatures of static eccentricity fault around fundamental and PSHs are detected successfully for saturated motor.

  16. Magnetic fields and uniformity of radio frequency power deposition in low-frequency inductively coupled plasmas with crossed internal oscillating currents

    DEFF Research Database (Denmark)

    Tsakadze, Erekle; Ostrikov, K.N.; Tsakadze, Z.L.

    2004-01-01

    ) discharge modes using two miniature magnetic probes. It is shown that the radial uniformity and depth of the rf power deposition can be improved as compared with conventional sources of inductively coupled plasmas with external flat spiral ("pancake") antennas. Relatively deeper rf power deposition...... in the plasma source results in more uniform profiles of the optical emission intensity, which indicates on the improvement of the plasma uniformity over large chamber volumes. The results of the numerical modeling of the radial magnetic field profiles are found in a reasonable agreement with the experimental...

  17. Power ion beam production in a magnetic-insulated diode placed in a circuit with an inductive storage with a plasmoerosion circuit breaker

    International Nuclear Information System (INIS)

    Anan'in, P.S.; Karpov, V.B.; Krasik, Ya.E.; Paul', E.A.

    1991-01-01

    Consideration is given to results of experimental studies of modes of operation of plasma current breaker and magnetic insulated diode, placed parallel in a circuit with inductive storage and microsecond generator, as well as parameters of high-power ion beam, generated in gas-filled diode. Magnetic field of mirror configuration, which enabled to locate the gas-filled diode dose to breaking region was used for decrease of electrodynamic plasma transfer. It is shown that time delay (of the order of ten and more) of power maximum in gas-filled diode with respect to power maximum in plasma breaker is observed when using passive plasma source on anode

  18. SAR and thermal response effects of a two-arm Archimedean spiral coil in a magnetic induction sensor on a human head.

    Science.gov (United States)

    Zhang, Ziyi; Liu, Peiguo; Zhou, Dongming; Zhang, Liang; Ding, Liang

    2015-01-01

    This study investigates the radiation safety of a newly designed magnetic induction sensor. This novel magnetic induction sensor uses a two-arm Archimedean spiral coil (TAASC) as the exciter. A human head model with a real anatomical structure was used to calculate the specific absorption rate (SAR) and temperature change. Computer Simulation Technology (CST) was used to determine the values of the peak 10-g SAR under different operating parameters (current, frequency, horizontal distance between the excitation coil and the receiver coil, vertical distance between the top of the head model and the XOY plane, position of excitation coil, and volume of hemorrhage). Then, the highest response for the SAR and temperature rise was determined. The results showed that this new magnetic induction sensor is safe in the initial state; for safety reasons, the TAASC current should not exceed 4 A. The scalp tissue absorbed most of the electromagnetic energy. The TAASC's SAR/thermal performance was close to that of the circular coil.

  19. LogScope

    Science.gov (United States)

    Havelund, Klaus; Smith, Margaret H.; Barringer, Howard; Groce, Alex

    2012-01-01

    LogScope is a software package for analyzing log files. The intended use is for offline post-processing of such logs, after the execution of the system under test. LogScope can, however, in principle, also be used to monitor systems online during their execution. Logs are checked against requirements formulated as monitors expressed in a rule-based specification language. This language has similarities to a state machine language, but is more expressive, for example, in its handling of data parameters. The specification language is user friendly, simple, and yet expressive enough for many practical scenarios. The LogScope software was initially developed to specifically assist in testing JPL s Mars Science Laboratory (MSL) flight software, but it is very generic in nature and can be applied to any application that produces some form of logging information (which almost any software does).

  20. Magnetic susceptibility and spectral gamma logs in the Tithonian-Berriasian pelagic carbonates in the Tatra Mts (Western Carpathians, Poland): Palaeoenvironmental changes at the Jurassic/Cretaceous boundary

    Czech Academy of Sciences Publication Activity Database

    Grabowski, J.; Schnyder, J.; Sobien, K.; Koptíková, Leona; Krzemiński, L.; Pszczółkowski, A.; Hejnar, J.; Schnabl, Petr

    2013-01-01

    Roč. 43, June 2013 (2013), s. 1-17 ISSN 0195-6671 Institutional support: RVO:67985831 Keywords : Berriasian * Gamma-ray spectrometry * magnetic susceptibility * palaeoenvironmental trends * Tithonian Subject RIV: DE - Earth Magnetism, Geodesy, Geography Impact factor: 2.390, year: 2013

  1. Speciation analysis of inorganic arsenic by magnetic solid phase extraction on-line with inductively coupled mass spectrometry determination.

    Science.gov (United States)

    Montoro Leal, P; Vereda Alonso, E; López Guerrero, M M; Cordero, M T Siles; Cano Pavón, J M; García de Torres, A

    2018-07-01

    Arsenic, one of the main environmental pollutants and potent natural poison, is a chemical element that is spread throughout the Earth's crust. It is well known that the toxicity of arsenic is highly dependent on its chemical forms. Generally, the inorganic species are more toxic than its organics forms, and As(III) is 60 times more toxic than As(V). In environmental waters, arsenic exists predominantly in two chemical forms: As(III) and As(V). In view of these facts, fast, sensitive, accurate and simple analytical methods for the speciation of inorganic arsenic in environmental waters are required. In this work, a new magnetic solid phase extraction with a hydride generation system was coupled on line with inductively coupled plasma mass spectrometry (MSPE-HG-ICP-MS). The new system was based on the retention of As(III) and As(V) in two knotted reactors filled with (Fe 3 O 4 ) magnetic nanoparticles functionalized with [1,5-bis (2-pyridyl) 3-sulfophenylmethylene] thiocarbonohydrazide (PSTH-MNPs). As(III) and total inorganic As were sequentially eluted in different reduction conditions. The concentration of As(V) was obtained by subtracting As(III) from total As. The system runs in a fully automated way and the method has proved to have a wide linear range and to be precise, sensitive and fast. The detection limits found were 2.7 and 3.2 ng/L for As(III) and total As, respectively; with relative standard deviations (RSDs) of 2.5% and 2.7% and a sample throughput of 14.4 h -1 . In order to validate the developed method, several certified reference samples of environmental waters including sea water, were analyzed and the determined values were in good agreement with the certified values. The proposed method was successfully applied to the speciation analysis of inorganic arsenic in well-water and sea water. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Induction Brazing

    DEFF Research Database (Denmark)

    Henningsen, Poul

    , or if the hottest area is located outside the joint interface, a number of defects may appear: the braze metal may flow away from the joint, the flux may burn off, poor binding of the braze metal may appear or the braze metal may be overheated. Joint geometry as well as electro-magnetic properties of the work piece...... presents a combined numerical and experimental method for determination of appropriate/optimiged coil geometry and position in induction brazing tube-to-plate joints of different ratios between tube and plate thickness and different combinations of the materials stainless steel, brass and copper....... The method has proven to give successful results in brazing tube-plate joints of copper-brass, copper-stainless steel, stainless steel-brass, and stainless steel-stainless steel. A new design of an adjustable flux concentrator for induction heating tube-to-plate joints is proposed and tested on a variety...

  3. Magnetic fields and uniformity of radio frequency power deposition in low-frequency inductively coupled plasmas with crossed internal oscillating currents

    International Nuclear Information System (INIS)

    Tsakadze, E.L.; Ostrikov, K.; Tsakadze, Z.L.; Vladimirov, S.V.; Xu, S.

    2004-01-01

    Radial and axial distributions of magnetic fields in a low-frequency (∼460 kHz) inductively coupled plasma source with two internal crossed planar rf current sheets are reported. The internal antenna configuration comprises two orthogonal sets of eight alternately reconnected parallel and equidistant copper litz wires in quartz enclosures and generates three magnetic (H z , H r , and H φ ) and two electric (E φ and E r ) field components at the fundamental frequency. The measurements have been performed in rarefied and dense plasmas generated in the electrostatic (E) and electromagnetic (H) discharge modes using two miniature magnetic probes. It is shown that the radial uniformity and depth of the rf power deposition can be improved as compared with conventional sources of inductively coupled plasmas with external flat spiral ('pancake') antennas. Relatively deeper rf power deposition in the plasma source results in more uniform profiles of the optical emission intensity, which indicates on the improvement of the plasma uniformity over large chamber volumes. The results of the numerical modeling of the radial magnetic field profiles are found in a reasonable agreement with the experimental data

  4. Well logging. Acquisition and applications; Diagraphies. Acquisition et applications

    Energy Technology Data Exchange (ETDEWEB)

    Serra, O.; Serra, L.

    2001-07-01

    This reference book on wire-line and LWD well logging covers all geophysical methods of underground survey in a synthetic, visual and dynamical way. It treats of: the physical principle of well logging measurements, the different types of existing probes, the factors that can influence the measurements, and the applications of these measurements. The following well-logging methods are reviewed: resistivity; electromagnetic wave propagation; magnetic susceptibility and magnetic field; spontaneous potential; nuclear logging: natural gamma radioactivity, density logging, photoelectric index, neutron emission probes, hydrogen index or neutron porosity, neutron induced gamma spectroscopy, neutron relaxation time, NMR; acoustic measurements: sonic logging, seismic profiles; texture, structure and stratigraphy data acquisition; borehole diameter measurement; temperature measurement; wire sampling methods; place and role of well-logging in petroleum exploration; well-logging programs. (J.S.)

  5. A Student Teamwork Induction Protocol

    Science.gov (United States)

    Kamau, Caroline; Spong, Abigail

    2015-01-01

    Faulty group processes have harmful effects on performance but there is little research about intervention protocols to pre-empt them in higher education. This naturalistic experiment compared a control cohort with an inducted cohort. The inducted cohort attended a workshop, consultations, elected a leader and used tools (a group log and group…

  6. Evaluating the accuracy of uranium isotope amount ratio measurements performed by a quadrupole and a multi-collector magnetic sector inductively coupled plasma mass spectrometers for nuclear safeguards

    International Nuclear Information System (INIS)

    Pereira de Oliveira, O. Jr.; Sarkis, J.E.S.; Ponzevera, E.; Alonso, A.; De Bolle, W.; Quetel, C.

    2008-01-01

    The n(U 235 )/n(U 238 ) isotope amount ratio in a set of samples was measured using two modern analytical techniques: quadrupole inductively coupled plasma mass spectrometry (ICP-QMS) and multi-collector magnetic sector inductively coupled plasma mass spectrometry (MC-ICPMS). The measured ratios were compared to the certified ratios provided by the high accuracy gas source mass spectrometry (GSMS). The components of the uncertainty were identified and their contribution to the combined standard uncertainty was estimated using the recommendations of the ISO-GUM guide. The values of the measurement uncertainty and bias were determined and then compared to the International Target Values for Measurement Uncertainties in Safeguarding Nuclear Materials. It appears that only the measurements performed by MC-ICPMS can meet the stringent requirements of international nuclear safeguards. (authors)

  7. Radiometric well logging instruments

    International Nuclear Information System (INIS)

    Davydov, A.V.

    1975-01-01

    The technical properties of well instruments for radioactive logging used in the radiometric logging complexes PKS-1000-1 (''Sond-1'') and PRKS-2 (''Vitok-2'') are described. The main features of the electric circuit of the measuring channels are given

  8. Power to the logs!

    CERN Multimedia

    CERN. Geneva; MACMAHON, Joseph

    2015-01-01

    Are you tired of using grep, vi and emacs to read your logs? Do you feel like you’re missing the big picture? Does the word "statistics" put a smile on your face? Then it’s time to give power to the logs!

  9. Data logging system upgrade for Indus accelerator

    International Nuclear Information System (INIS)

    Mishra, R.; Merh, B.N.; Agrawal, R.K.; Fatnani, P.; Navathe, C.P.; Pal, S.

    2012-01-01

    An accelerator has various subsystems like Magnet Power Supply, Beam Diagnostics and Vacuum etc. which are required to work in a stable manner to ensure required machine performance. Logging of system parameters at a faster rate plays a crucial role in analysing and understanding machine behaviour. Logging all the machine parameters consistently at the rate of typically more than 1 Hz has been the aim of a recent data logging system upgrade. Nearly ten thousand parameters are being logged at varying intervals of one second to one minute in Indus accelerator complex. The present logging scheme is augmented to log all these parameters at a rate equal to or more than 1 Hz. The database schema is designed according to the data type of the parameter. The data is distributed into historical table and intermediate table which comprises of recent data. Machine control applications read the parameter values from the control system and store them into the text files of finite time duration for each sub-system. The logging application of each sub-system passes these text files to database for bulk insertion. The detail design of database, logging scheme and its architecture is presented in the paper. (author)

  10. Digital mineral logging system

    International Nuclear Information System (INIS)

    West, J.B.

    1980-01-01

    A digital mineral logging system acquires data from a mineral logging tool passing through a borehole and transmits the data uphole to an electronic digital signal processor. A predetermined combination of sensors, including a deviometer, is located in a logging tool for the acquisition of the desired data as the logging tool is raised from the borehole. Sensor data in analog format is converted in the logging tool to a digital format and periodically batch transmitted to the surface at a predetermined sampling rate. An identification code is provided for each mineral logging tool, and the code is transmitted to the surface along with the sensor data. The self-identifying tool code is transmitted to the digital signal processor to identify the code against a stored list of the range of numbers assigned to that type of tool. The data is transmitted up the d-c power lines of the tool by a frequency shift key transmission technique. At the surface, a frequency shift key demodulation unit transmits the decoupled data to an asynchronous receiver interfaced to the electronic digital signal processor. During a recording phase, the signals from the logging tool are read by the electronic digital signal processor and stored for later processing. During a calculating phase, the stored data is processed by the digital signal processor and the results are outputted to a printer or plotter, or both

  11. Magnetic susceptibility measuring probe utilizing a compensation coil

    International Nuclear Information System (INIS)

    Bonnet, Jean; Fournet, Julien.

    1978-01-01

    This invention concerns a magnetic susceptibility measuring probe. It is used, inter alia, in logging, to wit continuous logging of the magnetic susceptibility of the ground throughout the length of a bore hole. The purpose of this invention is to increase the sensitivity of this type of probe by creating a side focusing effect . To this end, it provides for the use of a compensation winding, coaxial with the measurement winding and arranged symmetrically to the latter with respect to the centre of the induction windings [fr

  12. Mariners Weather Log

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Mariners Weather Log (MWL) is a publication containing articles, news and information about marine weather events and phenomena, worldwide environmental impact...

  13. Log-inject-log in sand consolidation

    International Nuclear Information System (INIS)

    Murphy, R.P.; Spurlock, J.W.

    1977-01-01

    A method is described for gathering information for the determination of the adequacy of placement of sand consolidating plastic for sand control in oil and gas wells. The method uses a high neutron cross-section tracer which becomes part of the plastic and uses pulsed neutron logging before and after injection of the plastic. Preferably, the method uses lithium, boron, indium, and/or cadmium tracers. Boron oxide is especially useful and can be dissolved in alcohol and mixed with the plastic ingredients

  14. Elephant logging and environment

    International Nuclear Information System (INIS)

    Tin-Aung-Hla

    1995-01-01

    The natural environment comprises non-biological elements such as air, water, light, heat and biological elements of animal and plant life; all interact with each other to create an ecosystem. Human activities like over-exploitation of forest results in deforestation and desertification. This consequently changes ecological balance. Topics on: (1) history of elephants utilization; (2) elephant logging; (3) classification of elephants; (4) dragging gear; (5) elephant power; (6) elephant logging and environment, are discussed

  15. Magnetic induction measurements and identification of the permeability of Magneto-Rheological Elastomers using finite element simulations

    International Nuclear Information System (INIS)

    Schubert, Gerlind; Harrison, Philip

    2016-01-01

    The isotropic and anisotropic magnetic permeability of Magneto-Rheological Elastomers (MREs) is identified using a simple inverse modelling approach. This involves measuring the magnetic flux density and attractive force occurring between magnets, when MRE specimens are placed in between the magnets. Tests were conducted using isotropic MREs with 10–40% and for anisotropic MREs with 10–30%, particle volume concentration. Magnetic permeabilities were then identified through inverse modelling, by simulating the system using commercially available multi-physics finite element software. As expected, the effective permeability of isotropic MREs was found to be scalar-valued; increasing with increasing particle volume concentration (from about 1.6 at 10% to 3.7 at 30% particle volume concentration). The magnetic permeability of transversely isotropic MRE was itself found to be transversely isotropic, with permeabilities in the direction of particle chain alignment from 1.6 at 10% to 4.45 at 30%, which is up to 1.07–1.25 times higher than in the transverse directions. Results of this investigation are demonstrated to show good agreement with those reported in the literature. - Highlights: • An inverse modelling approach for permeability identification of MREs. • Comparison of magnetic flux measurements with finite element simulations. • Permeability of isotropic and anisotropic MREs of varying iron content identified. • Results compare favourably with theoretical predictions. • Simple experimental setup. • Inexpensive technique that can be conducted in most mechanical test labs.

  16. Methods of assembling large magnetic blocks from NdFeB magnets with a high value of (BH)max and their influence on the magnetic induction reached in an air gap of magnetic circuit

    Czech Academy of Sciences Publication Activity Database

    Žežulka, Václav; Straka, Pavel

    2008-01-01

    Roč. 44, č. 4 (2008), s. 485-491 ISSN 0018-9464 Institutional research plan: CEZ:AV0Z30460519 Keywords : assembly * demagnetization * magnet ic circuits Subject RIV: BM - Solid Matter Physics ; Magnet ism Impact factor: 1.129, year: 2008

  17. Curing of a Bisphenol-E Based Cyanate Ester using Magnetic Nanoparticles as an Internal Heat Source through Induction Heating

    Science.gov (United States)

    2013-11-01

    reactions forming high-temperature thermosetting polymers and for innovative ways to process such polymers. 15. SUBJECT TERMS 16. SECURITY...reaction should allow for other reactions forming high-temperature thermosetting polymers and for innovative ways to process such polymers...generated by the particles in a polymer,18 1 µm nickel alloy (Nitinol) used to compare polymerizations with conventional or induction heating,19 or a

  18. Induction heating of thin metal plates in time-varying external magnetic field solved as nonlinear hard-coupled problem

    Czech Academy of Sciences Publication Activity Database

    Doležel, Ivo; Kropík, P.; Ulrych, B.

    2013-01-01

    Roč. 219, č. 13 (2013), s. 7159-7169 ISSN 0096-3003 R&D Projects: GA ČR GA102/09/1305 Grant - others:GA MŠk(CZ) MEB051041 Institutional support: RVO:61388998 Keywords : induction heating * electric field * temperature field Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.600, year: 2013 http://www.sciencedirect.com/science/article/pii/S0096300311010824

  19. Comparison of 2D and 3D magnetic field analysis of single-phase shaded pole induction motors

    Directory of Open Access Journals (Sweden)

    Adem Dalcali

    2016-03-01

    Full Text Available There has always been doubt on the accuracy of 2D analysis of small electric machines. To investigate the validity of this doubt, in this present work a small uni-coil shaded-pole induction motor is analyzed in 2D and 3D and the results are compared. In order to maintain the paper size as compact, the analysis is limited to the air-gap flux density distribution, variation of the main winding inductance against current and the force acting on the rotor body; which are the important components of the motor performance. It is found that although 3D analysis consumes several times more computing time and storage space, improvement achieved in performance by use of 3D analysis is not very significant. % rms difference between the two cases is obtained as 0.76% for the main winding inductance and 0.59% for the force acting on the rotor body. Also the air-gap flux density distribution obtained from the two types of analysis is found to be very close to each other. Therefore it is concluded that despite more computing time, more storage requirements and more human effort in the case of 3D analysis, the degree of improvement is not proportionally rewarding, and hence, 2D analysis is sufficient for the analysis of small machines.

  20. Characteristic and magnetic field analysis of a high temperature superconductor axial-flux coreless induction maglev motor.

    Science.gov (United States)

    Wei, Qin; Yu, Fan; Jin, Fang; Shuo, Li; Guoguo, Li; Gang, Lv

    2012-04-01

    A new high temperature superconductor axial-flux coreless maglev motor (HTS AFIM) is proposed, of which the primary windings are made of HTS tapes and the secondary is a non-magnetic conductor. The main works of this paper are the magnetic-field computation and characteristics analysis of HTS AFIM. For the first one, the reduction of magnetic fields near outer and inner radius of the HTS AFIM is solved by introducing the sub-loop electro-magnetic model along the radial position. For the second one, the AC losses of HTS coils are calculated. The relationships between the device's characteristics and device parameters are presented, and the results indicate that under certain frequency and current levitation device can output enough lift force. The conclusions are verified by finite element calculations.

  1. Log4J

    CERN Document Server

    Perry, Steven

    2009-01-01

    Log4j has been around for a while now, and it seems like so many applications use it. I've used it in my applications for years now, and I'll bet you have too. But every time I need to do something with log4j I've never done before I find myself searching for examples of how to do whatever that is, and I don't usually have much luck. I believe the reason for this is that there is a not a great deal of useful information about log4j, either in print or on the Internet. The information is too simple to be of real-world use, too complicated to be distilled quickly (which is what most developers

  2. A Novel Hysteresis Model of Magnetic Field Strength Determined by Magnetic Induction Intensity for Fe-3% Si Electrical Steel Applied in Cigarette Making Machines

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2016-01-01

    Full Text Available Hysteresis characteristics of grain-oriented electrical steel were studied through the hysteresis loop. Existing hysteresis fitting simulation methods were summarized, and new Fe-3% Si grain-oriented electrical steel hysteresis loop model was proposed. Undetermined coefficients of the magnetic field intensity and magnetic flux density were determined by both the fixed angle method and the least squares method, and the hysteresis loop model was validated with high fitting degree by experimental data.

  3. Determination of Tributyltin in Seafood Based on Magnetic Molecularly Imprinted Polymers Coupled with High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hua Yang

    2017-01-01

    Full Text Available In this study, Fe3O4 was adopted as a carrier for surface molecular imprinting with two-stage polymerization. First, the functional monomer (methacrylic acid, MAA was modified on the surface of Fe3O4, which was then polymerized with the template molecule (tributyltin, TBT, cross linking agent (ethylene glycol dimethacrylate, EGDMA, and porogen (acetonitrile, hereby successfully preparing Fe3O4@MIPs prone to specifically identify TBT. The physical properties of Fe3O4@MIPs were then characterized, and adsorption and selection capacities were also assessed. Compared with conventional imprinting polymers, this magnetic molecular imprinting polymer (MIP displayed significantly increased and more specific adsorption. Meanwhile, its pretreatment was simpler and faster due to magnetic separation characteristics. Using magnetic MIPs as adsorbents for enrichment and separation, detection limit, recovery rate, and linear range were 1.0 ng g−1, 79.74–95.72%, and 5 ng g−1~1000 ng g−1, respectively, for a number of seafood samples. High-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS was used to analyze Tegillarca granosa, mussels, large yellow croaker, and other specimens, with recovery rates of 79.74–95.72% and RSD of 1.3%–4.7%. Overall, this method has a shorter total analysis time, lower detection limit, and wider linear range and can be more effectively applied to determine MAA in seawater and seafood.

  4. Effect of a uniform magnetic induction field upon the flow of an electrically conducting fluid placed in a straight rectangular cross section, one of the walls of which, characterized by an infinite conductivity, presents uniform translation movement

    International Nuclear Information System (INIS)

    Herve, Patrick

    1975-01-01

    This is a theoretical study of an electrically viscous fluid flowing in a straight rectangular cross section channel, a wall of which, infinitely conducting, is placed perpendicularly to the direction of a uniform magnetic induction field. The three other walls of the channel being electrically insulating, remain motionless. Formulas giving velocity distribution law in the straight section of the flow in relation to the Hartmann's number, curves illustrating the accelerating effect produced across the whole section, by the application of the magnetic induction field, and example for the distribution of the electric current lines in case of a square section are given [fr

  5. Logging Concessions Enable Illegal Logging Crisis in the Peruvian Amazon

    OpenAIRE

    Finer, Matt; Jenkins, Clinton N.; Sky, Melissa A. Blue; Pine, Justin

    2014-01-01

    The Peruvian Amazon is an important arena in global efforts to promote sustainable logging in the tropics. Despite recent efforts to achieve sustainability, such as provisions in the US?Peru Trade Promotion Agreement, illegal logging continues to plague the region. We present evidence that Peru's legal logging concession system is enabling the widespread illegal logging via the regulatory documents designed to ensure sustainable logging. Analyzing official government data, we found that 68.3%...

  6. Log of Apollo 11.

    Science.gov (United States)

    National Aeronautics and Space Administration, Washington, DC.

    The major events of the first manned moon landing mission, Apollo 11, are presented in chronological order from launch time until arrival of the astronauts aboard the U.S.S. Hornet. The log is descriptive, non-technical, and includes numerous color photographs of the astronauts on the moon. (PR)

  7. Borehole logging system

    International Nuclear Information System (INIS)

    Allen, L.S.

    1988-01-01

    A radioactive borehole logging tool employs an epithermal neutron detector having a neutron counter surrounded by an inner thermal neutron filter and an outer thermal neutron filter. Located between the inner and outer filters is a neutron moderating material for extending the lifetime of epithermal neutrons to enhance the counting rate of such epithermal neutrons by the neutron counter

  8. Half Bridge Inductive Heater

    Directory of Open Access Journals (Sweden)

    Zoltán GERMÁN-SALLÓ

    2015-12-01

    Full Text Available Induction heating performs contactless, efficient and fast heating of conductive materials, therefore became one of the preferred heating procedure in industrial, domestic and medical applications. During induction heating the high-frequency alternating currents that heat the material are induced by means of electromagnetic induction. The material to be heated is placed inside the time-varying magnetic field generated by applying a highfrequency alternating current to an induction coil. The alternating electromagnetic field induces eddy currents in the workpiece, resulting resistive losses, which then heat the material. This paper describes the design of a power electronic converter circuit for induction heating equipment and presents the obtained results. The realized circuit is a low power half bridge resonant inverter which uses power MOS transistors and adequate driver circuits.

  9. Effects of slotting and unipolar flux on magnetic pull in a two-pole induction motor with an extra four-pole stator winding

    Energy Technology Data Exchange (ETDEWEB)

    Sinervo, A.

    2013-06-01

    This thesis is about the radial magnetic forces between the rotor and stator in twopole induction machines. The magnetic forces arise from rotor eccentricity. The asymmetric air-gap makes the flux density on one side of the rotor stronger than on the opposite side. This produces magnetic pull. The magnetic flux density distribution in the air-gap can be expressed with spatial harmonics, i.e. flux densities with different pole-pair numbers. In two-pole machines, the main part of the magnetic force is produced by the interaction of two- and fourpole flux unless the four-pole flux is damped by parallel paths in the stator winding or an extra four-pole stator winding. The rest of the force comes from the interaction of two-pole and unipolar flux and from the higher harmonics of the air-gap flux of which the slot harmonics are a major part. The force caused by the higher harmonics and the unipolar flux is studied in the case where a four-pole stator winding is used to reduce the four-pole flux. The higher harmonics are found to produce, in addition to the traditional unbalanced magnetic pull, a force similar to the effect of the unipolar flux and the two can be distinguished only by measuring the unipolar flux. In measurements at various operation points, the higher harmonics are found to produce much more force than the unipolar flux and two-pole flux but the unipolar flux is still significant. The four-pole winding also is used to actively control the four-pole flux and the magnetic forces. Designing the controller requires a low order model of the system. Such a model is derived and the effect of the slot harmonics and the unipolar flux are included in the model. Different measurements techniques and methods are presented to identify and validate the control model. The operation point dependence of the system dynamics is studied via measurements. All results are obtained from a 30 kW test motor. The rotor of the test machine has a long flexible shaft on external

  10. Well logging instrumental and methodological research

    International Nuclear Information System (INIS)

    Andrassy, L.; Barath, I.; Dorko, R.

    1983-01-01

    This part of the Annual Report of the Roland Eoetvoes Geophysical Institute (ELGI) of Hungary for 1982, summarizes the well logging instrumental and methodological researches of ELGI. The theoretical neutron diffusion fluxes for black and brown coals of Hungarian mines were calculated. A coal probe was developed and tested in boreholes using computerized data processing and interpretation. An X-ray radiometric method was used for the determination of Cu and Fe contents of minerals. Researches in the field of magnetic susceptibility and induced polarization logging are also summarized. A rapid analyzer for bauxite mining and a photorecorder for petroleum industry were developed by ELGI. (D.Gy.)

  11. High-induction nanocrystalline soft magnetic Fe{sub X}Ti{sub Y}B{sub Z} films prepared by magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Sheftel, Elena N.; Tedzhetov, Valentin A.; Harin, Eugene V.; Usmanova, Galina Sh. [A.A. Baikov Institute of Metallurgy and Material Science, Russian Academy of Sciences, Moscow (Russian Federation); Kiryukhantsev-Korneev, Filipp V. [National University of Science and Technology ' ' MISIS' ' , Moscow (Russian Federation)

    2016-12-15

    To design films with the Fe/TiB{sub 2} nanocomposite structure, which are characterized by high saturation induction B{sub s}, the phase and structural states and static magnetic properties of Fe-TiB{sub 2} films prepared by magnetron sputtering and subjected to subsequent annealing have been studied. According to X-ray diffraction data, either amorphous or nanocrystalline single-phase structure (an α-Fe(Ti,B) supersaturated solid solution with a bcc crystal lattice) is formed in the as-sputtered films. Depending on the film composition, the grain size of the α-Fe(Ti,B) phase varies from 45.6 to 6.5 nm; grains are characterized by high microstrain (0.21-4.96%). The annealing at 200-500 C leads to a decrease in the lattice parameter of the α-Fe(Ti,B) phase, i.e. to its depletion of titanium and boron and to the formation of two-phase α-Fe + Fe{sub 3}B structure after annealing at 500 C. The annealing at 200-500 C almost does not affect the grain size and microstrain of the bcc α-Fe-based phase. The amorphous state of the films is stable up to 500 C. All studied films are ferromagnets; the saturation induction B{sub s}(0.95-2.13 T) and coercive field H{sub c} (0.4-5 kA/m) of the films were determined. Correlations between the B{sub s} and H{sub c} magnitudes and the chemical composition of the films, their phase and structural states and magnetic structure are discussed. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. Magnetic immunoassay coupled with inductively coupled plasma mass spectrometry for simultaneous quantification of alpha-fetoprotein and carcinoembryonic antigen in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xing; Chen, Beibei; He, Man; Zhang, Yiwen; Xiao, Guangyang; Hu, Bin, E-mail: binhu@whu.edu.cn

    2015-04-01

    The absolute quantification of glycoproteins in complex biological samples is a challenge and of great significance. Herein, 4-mercaptophenylboronic acid functionalized magnetic beads were prepared to selectively capture glycoproteins, while antibody conjugated gold and silver nanoparticles were synthesized as element tags to label two different glycoproteins. Based on that, a new approach of magnetic immunoassay-inductively coupled plasma mass spectrometry (ICP-MS) was established for simultaneous quantitative analysis of glycoproteins. Taking biomarkers of alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) as two model glycoproteins, experimental parameters involved in the immunoassay procedure were carefully optimized and analytical performance of the proposed method was evaluated. The limits of detection (LODs) for AFP and CEA were 0.086 μg L{sup −1} and 0.054 μg L{sup −1} with the relative standard deviations (RSDs, n = 7, c = 5 μg L{sup −1}) of 6.5% and 6.2% for AFP and CEA, respectively. Linear range for both AFP and CEA was 0.2–50 μg L{sup −1}. To validate the applicability of the proposed method, human serum samples were analyzed, and the obtained results were in good agreement with that obtained by the clinical chemiluminescence immunoassay. The developed method exhibited good selectivity and sensitivity for the simultaneous determination of AFP and CEA, and extended the applicability of metal nanoparticle tags based on ICP-MS methodology in multiple glycoprotein quantifications. - Highlights: • 4-Mercaptophenylboronic acid functionalized magnetic beads were prepared and characterized. • ICP-MS based magnetic immunoassay approach was developed for quantification of glycoproteins. • AFP and CEA were quantified simultaneously with Au and Ag NPs as element tags. • The developed method exhibited good selectivity and sensitivity for target glycoproteins.

  13. Optically transmitted and inductively coupled electric reference to access in vivo concentrations for quantitative proton-decoupled ¹³C magnetic resonance spectroscopy.

    Science.gov (United States)

    Chen, Xing; Pavan, Matteo; Heinzer-Schweizer, Susanne; Boesiger, Peter; Henning, Anke

    2012-01-01

    This report describes our efforts on quantification of tissue metabolite concentrations in mM by nuclear Overhauser enhanced and proton decoupled (13) C magnetic resonance spectroscopy and the Electric Reference To access In vivo Concentrations (ERETIC) method. Previous work showed that a calibrated synthetic magnetic resonance spectroscopy-like signal transmitted through an optical fiber and inductively coupled into a transmit/receive coil represents a reliable reference standard for in vivo (1) H magnetic resonance spectroscopy quantification on a clinical platform. In this work, we introduce a related implementation that enables simultaneous proton decoupling and ERETIC-based metabolite quantification and hence extends the applicability of the ERETIC method to nuclear Overhauser enhanced and proton decoupled in vivo (13) C magnetic resonance spectroscopy. In addition, ERETIC signal stability under the influence of simultaneous proton decoupling is investigated. The proposed quantification method was cross-validated against internal and external reference standards on human skeletal muscle. The ERETIC signal intensity stability was 100.65 ± 4.18% over 3 months including measurements with and without proton decoupling. Glycogen and unsaturated fatty acid concentrations measured with the ERETIC method were in excellent agreement with internal creatine and external phantom reference methods, showing a difference of 1.85 ± 1.21% for glycogen and 1.84 ± 1.00% for unsaturated fatty acid between ERETIC and creatine-based quantification, whereas the deviations between external reference and creatine-based quantification are 6.95 ± 9.52% and 3.19 ± 2.60%, respectively. Copyright © 2011 Wiley Periodicals, Inc.

  14. Multi-Sensor Systems Development for UXO Detection and Discrimination: Man-Portable Dual Magnetic/Electromagnetic Induction Sensor

    Science.gov (United States)

    2008-02-01

    of the magnetic data to constrain the target depth using joint or cooperative inversions ( Pasion et al. 2002). ERDC/EL TR-08-9 24 Figure 15. EM...baseline ordnance classification test site at Blossom Pt. Naval Research Laboratory. NRL/MR/6110-00-8437, March 20, 1998. Pasion , L., S. Billings, and

  15. Cortical Plasticity Induction by Pairing Subthalamic Nucleus Deep-Brain Stimulation and Primary Motor Cortical Transcranial Magnetic Stimulation in Parkinson's Disease.

    Science.gov (United States)

    Udupa, Kaviraja; Bahl, Nina; Ni, Zhen; Gunraj, Carolyn; Mazzella, Filomena; Moro, Elena; Hodaie, Mojgan; Lozano, Andres M; Lang, Anthony E; Chen, Robert

    2016-01-13

    Noninvasive brain stimulation studies have shown abnormal motor cortical plasticity in Parkinson's disease (PD). These studies used peripheral nerve stimulation paired with transcranial magnetic stimulation (TMS) to primary motor cortex (M1) at specific intervals to induce plasticity. Induction of cortical plasticity through stimulation of the basal ganglia (BG)-M1 connections has not been studied. In the present study, we used a novel technique of plasticity induction by repeated pairing of deep-brain stimulation (DBS) of the BG with M1 stimulation using TMS. We hypothesize that repeated pairing of subthalamic nucleus (STN)-DBS and M1-TMS at specific time intervals will lead to plasticity in the M1. Ten PD human patients with STN-DBS were studied in the on-medication state with DBS set to 3 Hz. The interstimulus intervals (ISIs) between STN-DBS and TMS that produced cortical facilitation were determined individually for each patient. Three plasticity induction conditions with repeated pairings (180 times) at specific ISIs (∼ 3 and ∼ 23 ms) that produced cortical facilitation and a control ISI of 167 ms were tested in random order. Repeated pairing of STN-DBS and M1-TMS at short (∼ 3 ms) and medium (∼ 23 ms) latencies increased M1 excitability that lasted for at least 45 min, whereas the control condition (fixed ISI of 167 ms) had no effect. There were no specific changes in motor thresholds, intracortical circuits, or recruitment curves. Our results indicate that paired-associative cortical plasticity can be induced by repeated STN and M1 stimulation at specific intervals. These results show that STN-DBS can modulate cortical plasticity. We introduced a new experimental paradigm to test the hypothesis that pairing subthalamic nucleus deep-brain stimulation (STN-DBS) with motor cortical transcranial magnetic stimulation (M1-TMS) at specific times can induce cortical plasticity in patients with Parkinson's disease (PD). We found that repeated pairing of STN

  16. Neutron--neutron logging

    International Nuclear Information System (INIS)

    Allen, L.S.

    1977-01-01

    A borehole logging tool includes a steady-state source of fast neutrons, two epithermal neutron detectors, and two thermal neutron detectors. A count rate meter is connected to each neutron detector. A first ratio detector provides an indication of the porosity of the formation surrounding the borehole by determining the ratio of the outputs of the two count rate meters connected to the two epithermal neutron detectors. A second ratio detector provides an indication of both porosity and macroscopic absorption cross section of the formation surrounding the borehole by determining the ratio of the outputs of the two count rate meters connected to the two thermal neutron detectors. By comparing the signals of the two ratio detectors, oil bearing zones and salt water bearing zones within the formation being logged can be distinguished and the amount of oil saturation can be determined. 6 claims, 2 figures

  17. Pulsed radiation decay logging

    International Nuclear Information System (INIS)

    Mills, W.R. Jr.

    1983-01-01

    There are provided new and improved well logging processes and systems wherein the detection of secondary radiation is accomplished during a plurality of time windows in a manner to accurately characterize the decay rate of the secondary radiation. The system comprises a well logging tool having a primary pulsed radiation source which emits repetitive time-spaced bursts of primary radiation and detector means for detecting secondary radiation resulting from the primary radiation and producing output signals in response to the detected radiation. A plurality of measuring channels are provided, each of which produces a count rate function representative of signals received from the detector means during successive time windows occurring between the primary radiation bursts. The logging system further comprises means responsive to the measuring channels for producing a plurality of functions representative of the ratios of the radiation count rates measured during adjacent pairs of the time windows. Comparator means function to compare the ratio functions and select at least one of the ratio functions to generate a signal representative of the decay rate of the secondary radiation

  18. Geophysical borehole logging

    International Nuclear Information System (INIS)

    McCann, D.; Barton, K.J.; Hearn, K.

    1981-08-01

    Most of the available literature on geophysical borehole logging refers to studies carried out in sedimentary rocks. It is only in recent years that any great interest has been shown in geophysical logging in boreholes in metamorphic and igneous rocks following the development of research programmes associated with geothermal energy and nuclear waste disposal. This report is concerned with the programme of geophysical logging carried out on the three deep boreholes at Altnabreac, Caithness, to examine the effectiveness of these methods in crystalline rock. Of particular importance is the assessment of the performance of the various geophysical sondes run in the boreholes in relation to the rock mass properties. The geophysical data can be used to provide additional in-situ information on the geological, hydrogeological and engineering properties of the rock mass. Fracturing and weathering in the rock mass have a considerable effect on both the design parameters for an engineering structure and the flow of water through the rock mass; hence, the relation between the geophysical properties and the degree of fracturing and weathering is examined in some detail. (author)

  19. Magnetic immunoassay coupled with inductively coupled plasma mass spectrometry for simultaneous quantification of alpha-fetoprotein and carcinoembryonic antigen in human serum

    Science.gov (United States)

    Zhang, Xing; Chen, Beibei; He, Man; Zhang, Yiwen; Xiao, Guangyang; Hu, Bin

    2015-04-01

    The absolute quantification of glycoproteins in complex biological samples is a challenge and of great significance. Herein, 4-mercaptophenylboronic acid functionalized magnetic beads were prepared to selectively capture glycoproteins, while antibody conjugated gold and silver nanoparticles were synthesized as element tags to label two different glycoproteins. Based on that, a new approach of magnetic immunoassay-inductively coupled plasma mass spectrometry (ICP-MS) was established for simultaneous quantitative analysis of glycoproteins. Taking biomarkers of alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) as two model glycoproteins, experimental parameters involved in the immunoassay procedure were carefully optimized and analytical performance of the proposed method was evaluated. The limits of detection (LODs) for AFP and CEA were 0.086 μg L- 1 and 0.054 μg L- 1 with the relative standard deviations (RSDs, n = 7, c = 5 μg L- 1) of 6.5% and 6.2% for AFP and CEA, respectively. Linear range for both AFP and CEA was 0.2-50 μg L- 1. To validate the applicability of the proposed method, human serum samples were analyzed, and the obtained results were in good agreement with that obtained by the clinical chemiluminescence immunoassay. The developed method exhibited good selectivity and sensitivity for the simultaneous determination of AFP and CEA, and extended the applicability of metal nanoparticle tags based on ICP-MS methodology in multiple glycoprotein quantifications.

  20. One less trip : logging with less tripping, more protection

    Energy Technology Data Exchange (ETDEWEB)

    Byfield, M.

    2005-12-15

    New logging technology by Datalog Technology Inc. was described. Logging-while-tripping (LWT) technology uses a slim petrophysical sensor package that is moved to the targeted geological formation through a drill pipe, which reduces the exposure to vibration and shock involved in logging-while-drilling (LWD). The equipment features standard components in a patented configuration and comes in 2 segments: the receiver sub and the sensor package electronics. A receiver sub is inserted into the bottomhole assembly at the end of the drill string. Drilling progresses with the LWT sub in the bottomhole assembly until the borehole approaches the logging depth. The sensor package and electronics are then lowered into the drill string. If the well is horizontal, rig pumps push the package into the drill string until it lands in the LWT sub. Drill pipes are moved across the zone of interest and logs are recorded on downhole memory contained within the LWT package. As the logging operation progresses, a depth recorder at the surface records depth information along with the downhole recorders. When logging is completed, downhole tools are retrieved, and data downloaded from the LWT onboard memory is merged with the surface depth information to generate well logs. Retrieval via the drill string greatly reduces the risk of losing the logging gear, which contains radioactive material. Federal officials now routinely insist on extensive fishing operations to retrieve lost tools. If a well gets a gas kick while logging is in progress, the operator can still pump down mud or close the blowout preventer rams if necessary, and save time in determining where to perforate shallow gas wells. Compensated neutron logs, gamma rays, spectrum gamma rays, and induction have been tested with the LWT system. It was concluded that Petro-Canada has deployed the logs recently and has achieved results that compared satisfactorily with conventional logs. 2 figs.

  1. Labor Induction

    Science.gov (United States)

    f AQ FREQUENTLY ASKED QUESTIONS FAQ154 LABOR, DELIVERY, AND POSTPARTUM CARE Labor Induction • What is labor induction? • Why is labor induced? • What is the Bishop score? • What is “ripening ...

  2. Geophysical logging for mineral exploration and development

    International Nuclear Information System (INIS)

    Plouffe, R.D.

    1981-01-01

    It is possible to retrieve from small-diameter holes geophysical data for qualitative interpretation in exploration and quantitative interpretation in the development of orebodies. The primary objectives in the exploration stage are to identify where, within a hole, economic minerals are, and to help in lithological interpretations. Other aspects, which are more quantitative, are the interpretation of downhole logs for parameters which can be used in surface geophysical methods (i.e. density for gravity surveys, acoustic velocities for seismic surveys, and magnetic susceptibility for airborne and ground magnetic surveys). Recent advances in equipment design, portability and durability have made downhole logging in exploration more inexpensive and reliable. This new equipment is being used to generate very precise quantitative results. This is especially true on uranium development projects. The interpretation of gamma logs for eU 3 O 8 values has finally become precise enough that they have begun to replace chemical values in reserve calculations. Another part of development data is density and equilibrium information, which, with today's technology, is being derived from downhole probing. In the years to come, the trends for many metals are toward neutron activation techniques, or in-situ assaying, and the use of multiple logs for better lithological and physical rock property determinations. (auth)

  3. Pulse neutron logging technique

    International Nuclear Information System (INIS)

    Bespalov, D.F.; Dylyuk, A.A.

    1975-01-01

    A new method of neutron-burst logging is proposed, residing in irradiating rocks with fast neutron bursts and registering the integrated flux burst of thermal and/or epithermal neutrons, from the moment of its initiation to that of full absorption. The obtaained value is representative of the rock properties (porosity, hydrogen content). The integrated flux in a burst of thermal and epithermal neutrons can be measured both by way of activation of a reference sample of a known chemical composition during the neutron burst and by recording the radiation of induced activity of the sample within an interval between two bursts. The proposed method features high informative value, accuracy and efficiency

  4. Nuclear spin Hall and Klein tunneling effects during oxidation with electric and magnetic field inductions in graphene.

    Science.gov (United States)

    Little, Reginald B; McClary, Felicia; Rice, Bria; Jackman, Corine; Mitchell, James W

    2012-12-14

    The recent observation of the explosive oxidation of graphene with enhancement for decreasing temperature and the requirements for synchronizing oxidants for collective oxidation-reduction (redox) reactions presented a chemical scenario for the thermal harvesting by the magnetic spin Hall Effect. More experimental data are presented to demonstrate such spin Hall Effect by determining the influence of spins of so-called spectator fermionic cations. Furthermore, the so-called spectator bosonic cations are discovered to cause a Klein tunneling effect during the redox reaction of graphene. The Na(+) and K(+), fermionic cations and the Mg(2+) and Ca(2+), bosonic cations were observed and compared under a variety of experimental conditions: adiabatic reactions with initial temperatures (18-22 °C); reactions toward infinite dilution; isothermal reactions under nonadiabatic conditions at low temperature of 18 °C; reactions under paramagnetic O(2) or diamagnetic N(2) atmospheres of different permeabilities; reactions in applied and no applied external magnetic field; and reactions toward excess concentrations of common and uncommon Na(+) and Mg(2+) cations. The observed reaction kinetics and dynamics under these various, diverse conditions are consistent with the spin Hall mechanism, energy harvesting and short time violation of Second Law of Thermodynamics for redox reactions of graphene by the Na(+)K(+) mixture and are consistent with the Klein tunnel mechanism for the redox reactions of graphene by the Mg(2+)Ca(2+) mixture. Mixed spin Hall and Klein tunnel mechanisms are discovered to slow and modulate explosive redox reactions. Such spin Hall Effect also gives explanation of recent tunneling of electrons through boron nitride.

  5. Nova Event Logging System

    International Nuclear Information System (INIS)

    Calliger, R.J.; Suski, G.J.

    1981-01-01

    Nova is a 200 terawatt, 10-beam High Energy Glass Laser currently under construction at LLNL. This facility, designed to demonstrate the feasibility of laser driven inertial confinement fusion, contains over 5000 elements requiring coordinated control, data acquisition, and analysis functions. The large amounts of data that will be generated must be maintained over the life of the facility. Often the most useful but inaccessible data is that related to time dependent events associated with, for example, operator actions or experiment activity. We have developed an Event Logging System to synchronously record, maintain, and analyze, in part, this data. We see the system as being particularly useful to the physics and engineering staffs of medium and large facilities in that it is entirely separate from experimental apparatus and control devices. The design criteria, implementation, use, and benefits of such a system will be discussed

  6. Querying Workflow Logs

    Directory of Open Access Journals (Sweden)

    Yan Tang

    2018-01-01

    Full Text Available A business process or workflow is an assembly of tasks that accomplishes a business goal. Business process management is the study of the design, configuration/implementation, enactment and monitoring, analysis, and re-design of workflows. The traditional methodology for the re-design and improvement of workflows relies on the well-known sequence of extract, transform, and load (ETL, data/process warehousing, and online analytical processing (OLAP tools. In this paper, we study the ad hoc queryiny of process enactments for (data-centric business processes, bypassing the traditional methodology for more flexibility in querying. We develop an algebraic query language based on “incident patterns” with four operators inspired from Business Process Model and Notation (BPMN representation, allowing the user to formulate ad hoc queries directly over workflow logs. A formal semantics of this query language, a preliminary query evaluation algorithm, and a group of elementary properties of the operators are provided.

  7. Visualizing the Acute Effects of Vascular-Targeted Therapy In Vivo Using Intravital Microscopy and Magnetic Resonance Imaging: Correlation with Endothelial Apoptosis, Cytokine Induction, and Treatment Outcome

    Directory of Open Access Journals (Sweden)

    Mukund Seshadri

    2007-02-01

    Full Text Available The acute effects of the vascular-disrupting agent 5,6-dimethylxanthenone-4-acetic acid (DMXAA were investigated in vivo using intravital microscopy (IVM and magnetic resonance imaging (MRI. Changes in vascular permeability and blood flow of syngeneic CT-26 murine colon adenocarcinomas were assessed at 4 and 24 hours after DMXAA treatment (30 mg/kg, i.p. and correlated with induction of tumor necrosis factor-α (TNF-α, endothelial damage [CD31/terminal deoxynucleotidyl transferase (TdT], and treatment outcome. Intravital imaging revealed a marked increase in vascular permeability 4 hours after treatment, consistent with increases in intratumoral mRNA and protein levels of TNF-α. Parallel contrast-enhanced MRI studies showed a ~ 4-fold increase in longitudinal relaxation rates (ΔR1, indicative of increased contrast agent accumulation within the tumor. Dualimmunostained tumor sections (CD31/TdT revealed evidence of endothelial apoptosis at this time point. Twenty-four hours after treatment, extensive hemorrhage and complete disruption of vascular architecture were observed with IVM, along with a significant reduction in ΔR1 and virtual absence of CD31 immunostaining. DMXAA-induced tumor vascular damage resulted in significant long-term (60-day cures compared to untreated controls. Multimodality imaging approaches are useful in visualizing the effects of antivascular therapy in vivo. Such approaches allow cross validation and correlation of findings with underlying molecular changes contributing to treatment outcome.

  8. Effect of inter-train interval on the induction of repetition suppression of motor-evoked potentials using transcranial magnetic stimulation.

    Directory of Open Access Journals (Sweden)

    Minna Pitkänen

    Full Text Available Repetition suppression (RS is evident as a weakened response to repeated stimuli after the initial response. RS has been demonstrated in motor-evoked potentials (MEPs induced with transcranial magnetic stimulation (TMS. Here, we investigated the effect of inter-train interval (ITI on the induction of RS of MEPs with the attempt to optimize the investigative protocols. Trains of TMS pulses, targeted to the primary motor cortex by neuronavigation, were applied at a stimulation intensity of 120% of the resting motor threshold. The stimulus trains included either four or twenty pulses with an inter-stimulus interval (ISI of 1 s. The ITI was here defined as the interval between the last pulse in a train and the first pulse in the next train; the ITIs used here were 1, 3, 4, 6, 7, 12, and 17 s. RS was observed with all ITIs except with the ITI of 1 s, in which the ITI was equal to ISI. RS was more pronounced with longer ITIs. Shorter ITIs may not allow sufficient time for a return to baseline. RS may reflect a startle-like response to the first pulse of a train followed by habituation. Longer ITIs may allow more recovery time and in turn demonstrate greater RS. Our results indicate that RS can be studied with confidence at relatively short ITIs of 6 s and above.

  9. Twenty-Four-Hour Real-Time Continuous Monitoring of Cerebral Edema in Rabbits Based on a Noninvasive and Noncontact System of Magnetic Induction

    Directory of Open Access Journals (Sweden)

    Gen Li

    2017-03-01

    Full Text Available Cerebral edema is a common disease, secondary to craniocerebral injury, and real-time continuous monitoring of cerebral edema is crucial for treating patients after traumatic brain injury. This work established a noninvasive and noncontact system by monitoring the magnetic induction phase shift (MIPS which is associated with brain tissue conductivity. Sixteen rabbits (experimental group n = 10, control group, n = 6 were used to perform a 24 h MIPS and intracranial pressure (ICP simultaneously monitored experimental study. For the experimental group, after the establishment of epidural freeze-induced cerebral edema models, the MIPS presented a downward trend within 24 h, with a change magnitude of −13.1121 ± 2.3953°; the ICP presented an upward trend within 24 h, with a change magnitude of 12–41 mmHg. The ICP was negatively correlated with the MIPS. In the control group, the MIPS change amplitude was −0.87795 ± 1.5146 without obvious changes; the ICP fluctuated only slightly at the initial value of 12 mmHg. MIPS had a more sensitive performance than ICP in the early stage of cerebral edema. These results showed that this system is basically capable of monitoring gradual increases in the cerebral edema solution volume. To some extent, the MIPS has the potential to reflect the ICP changes.

  10. Inductive reasoning.

    Science.gov (United States)

    Hayes, Brett K; Heit, Evan; Swendsen, Haruka

    2010-03-01

    Inductive reasoning entails using existing knowledge or observations to make predictions about novel cases. We review recent findings in research on category-based induction as well as theoretical models of these results, including similarity-based models, connectionist networks, an account based on relevance theory, Bayesian models, and other mathematical models. A number of touchstone empirical phenomena that involve taxonomic similarity are described. We also examine phenomena involving more complex background knowledge about premises and conclusions of inductive arguments and the properties referenced. Earlier models are shown to give a good account of similarity-based phenomena but not knowledge-based phenomena. Recent models that aim to account for both similarity-based and knowledge-based phenomena are reviewed and evaluated. Among the most important new directions in induction research are a focus on induction with uncertain premise categories, the modeling of the relationship between inductive and deductive reasoning, and examination of the neural substrates of induction. A common theme in both the well-established and emerging lines of induction research is the need to develop well-articulated and empirically testable formal models of induction. Copyright © 2010 John Wiley & Sons, Ltd. For further resources related to this article, please visit the WIREs website. Copyright © 2010 John Wiley & Sons, Ltd.

  11. Interpretation of horizontal well production logs: influence of logging tool

    Energy Technology Data Exchange (ETDEWEB)

    Ozkan, E. [Colorado School of Mines, Boulder, CO (United States); Sarica, C. [Pennsylvania State Univ., College Park, PA (United States); Haci, M. [Drilling Measurements, Inc (United States)

    1998-12-31

    The influence of a production-logging tool on wellbore flow rate and pressure measurements was investigated, focusing on the disturbence caused by the production-logging tool and the coiled tubing on the original flow conditions in the wellbore. The investigation was carried out using an analytical model and single-phase liquid flow was assumed. Results showed that the production-logging tool influenced the measurements as shown by the deviation of the original flow-rate, pressure profiles and low-conductivity wellbores. High production rates increase the effect of the production-logging tool. Recovering or inferring the original flow conditions in the wellbore from the production-logging data is a very complex process which cannot be solved easily. For this reason, the conditions under which the information obtained by production-logging is meaningful is of considerable practical interest. 7 refs., 2 tabs., 15 figs.

  12. Results of mine logging in Sn-W prospectina in Cinovec deposit

    International Nuclear Information System (INIS)

    Kudrna, R.; Masek, K.; Pavlik, I.; Rejl, L.

    1984-01-01

    The method is suggested of indicating cassiterite ore mineralization in the Cinovec deposit by combining the methods of selective gamma-gamma logging and magnetic susceptibility logging. The estimate of the tin content was based on selective gamma-gamma logging. (B.S.)

  13. Physic basis of electromagnetic induction low

    Directory of Open Access Journals (Sweden)

    V.J. Kutkovetskyy

    2015-03-01

    Full Text Available The statement on the macro level of EMF dependence on change in magnetic flux in time wrong reflects the physical phenomenon of electromagnetic induction low by Faraday, because EMF can be inducted if the magnetic flux of the circuit does not change. Changing magnetic flux of the circuit when the electromotive force arises is only a result of crossing the magnetic field lines by conductor and is an exception, which applies only to certain classes of electric machines.

  14. Magnets

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    A magnet pole piece for an NMR imaging magnet is made of a plurality of magnetic wires with one end of each wire held in a non-magnetic spacer, the other ends of the wires being brought to a pinch, and connected to a magnetic core. The wires may be embedded in a synthetic resin and the magnetisation and uniformity thereof can be varied by adjusting the density of the wires at the spacer which forms the pole piece. (author)

  15. Linear induction accelerators

    International Nuclear Information System (INIS)

    Briggs, R.J.

    1986-06-01

    The development of linear induction accelerators has been motivated by applications requiring high-pulsed currents of charged particles at voltages exceeding the capability of single-stage, diode-type accelerators and at currents too high for rf accelerators. In principle, one can accelerate charged particles to arbitrarily high voltages using a multi-stage induction machine, but the 50-MeV, 10-kA Advanced Test Accelerator (ATA) at LLNL is the highest voltage machine in existence at this time. The advent of magnetic pulse power systems makes sustained operation at high-repetition rates practical, and this capability for high-average power is very likely to open up many new applications of induction machines in the future. This paper surveys the US induction linac technology with primary emphasis on electron machines. A simplified description of how induction machines couple energy to the electron beam is given, to illustrate many of the general issues that bound the design space of induction linacs

  16. ANDRILL Borehole AND-1B: Well Log Analysis of Lithofacies and Glacimarine Cycles.

    Science.gov (United States)

    Jackolski, C. L.; Williams, T.; Powell, R. D.; Jarrard, R.; Morin, R. H.; Talarico, F. M.; Niessen, F.; Kuhn, G.

    2008-12-01

    During the 2006-2007 austral summer, the Antarctic geological drilling program ANDRILL recovered cores of sedimentary rock from a 1285-m-deep borehole below the McMurdo Ice Shelf. Well logging instruments were deployed to a depth of 1017 mbsf after core recovery. This study focuses on two intervals of the AND-1B borehole: upper HQ (238-343 mbsf; Pliocene) and NQ (698-1017 mbsf; upper Miocene), which were logged with natural gamma ray, induction resistivity and magnetic susceptibility tools. To understand how the well logs fit into a more complete physical properties data set, we performed factor and cluster analyses on a suite of well logs and core logs in the upper HQ and NQ intervals. In both intervals, factor analysis groups resistivity and core P-velocity into a factor that we interpret as being inversely proportional to porosity. It also groups natural gamma and potassium (from the XRF core scanner) into a factor that we interpret as a particle-size or lithology index. An additional factor in the NQ interval, influenced by clast number and magnetic susceptibility, distinguishes subglacial diamictites from other lithofacies. The factors in each interval (2 in HQ, 3 in NQ) are used as input to cluster analysis. The results are log data objectively organized into clusters, or electrofacies. We compare these electrofacies to the lithofacies, well logs and unconformity-bounded glacimarine cycles of AND-1B. Patterns in the glacimarine cycles are observed in the well logs and electrofacies. In the NQ glacimarine sediments, an electrofacies pattern is produced between subglacial diamictites at the bottom of each sequence and the glacial retreat facies above. Subglacial diamictites have higher values for the additional NQ factor, corresponding to clast number and magnetic susceptibility, than the muds and sands that form the retreat facies. Differences in the porosity factor are not observed in any electrofacies pattern in the NQ interval, but subtle patterns in the

  17. Teacher induction

    NARCIS (Netherlands)

    Beijaard, D.; Buitink, J.; Kessels, C.; Peterson, P.; Baker, E.; McGraw, B.

    2010-01-01

    Teacher induction programs are intended to support the professional development of beginning teachers and thereby contribute to the reduction of teacher attrition during the early teaching years. Teacher induction programs are often based upon a deficit model with a focus on the better organization

  18. Logging Concessions Enable Illegal Logging Crisis in the Peruvian Amazon

    Science.gov (United States)

    Finer, Matt; Jenkins, Clinton N.; Sky, Melissa A. Blue; Pine, Justin

    2014-04-01

    The Peruvian Amazon is an important arena in global efforts to promote sustainable logging in the tropics. Despite recent efforts to achieve sustainability, such as provisions in the US-Peru Trade Promotion Agreement, illegal logging continues to plague the region. We present evidence that Peru's legal logging concession system is enabling the widespread illegal logging via the regulatory documents designed to ensure sustainable logging. Analyzing official government data, we found that 68.3% of all concessions supervised by authorities were suspected of major violations. Of the 609 total concessions, nearly 30% have been cancelled for violations and we expect this percentage to increase as investigations continue. Moreover, the nature of the violations indicate that the permits associated with legal concessions are used to harvest trees in unauthorized areas, thus threatening all forested areas. Many of the violations pertain to the illegal extraction of CITES-listed timber species outside authorized areas. These findings highlight the need for additional reforms.

  19. Logging concessions enable illegal logging crisis in the Peruvian Amazon.

    Science.gov (United States)

    Finer, Matt; Jenkins, Clinton N; Sky, Melissa A Blue; Pine, Justin

    2014-04-17

    The Peruvian Amazon is an important arena in global efforts to promote sustainable logging in the tropics. Despite recent efforts to achieve sustainability, such as provisions in the US-Peru Trade Promotion Agreement, illegal logging continues to plague the region. We present evidence that Peru's legal logging concession system is enabling the widespread illegal logging via the regulatory documents designed to ensure sustainable logging. Analyzing official government data, we found that 68.3% of all concessions supervised by authorities were suspected of major violations. Of the 609 total concessions, nearly 30% have been cancelled for violations and we expect this percentage to increase as investigations continue. Moreover, the nature of the violations indicate that the permits associated with legal concessions are used to harvest trees in unauthorized areas, thus threatening all forested areas. Many of the violations pertain to the illegal extraction of CITES-listed timber species outside authorized areas. These findings highlight the need for additional reforms.

  20. A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support

    Science.gov (United States)

    Shen, Yang-Wu; Ke, De-Ping; Sun, Yuan-Zhang; Daniel, Kirschen; Wang, Yi-Shen; Hu, Yuan-Chao

    2015-07-01

    A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator (DFIG) equipped with a superconducting magnetic energy storage (SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter (GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter (RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive (priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. Project supported by the National Natural Science Foundation of China (Grant No. 51307124) and the Major Program of the National Natural Science Foundation of China (Grant No. 51190105).

  1. Determination of avian influenza A (H9N2) virions by inductively coupled plasma mass spectrometry based magnetic immunoassay with gold nanoparticles labeling

    Science.gov (United States)

    Xiao, Guangyang; Chen, Beibei; He, Man; Shi, Kaiwen; Zhang, Xing; Li, Xiaoting; Wu, Qiumei; Pang, Daiwen; Hu, Bin

    2017-12-01

    Avian influenza viruses are the pathogens of global poultry epidemics, and may even cause the human infections. Here, we proposed a novel inductively coupled plasma mass spectrometry (ICP-MS) based immunoassay with gold nanoparticles (Au NPs) labeling for the determination of H9N2 virions. Magnetic-beads modified with anti-influenza A H9N2 hemagglutinin mono-antibody (mAb-HA) were utilized for the capture of H9N2 virions in complex matrix; and Au NPs conjugated with mAb-HA were employed for the specific labeling of H9N2 virions for subsequent ICP-MS detection. With a sandwich immunoassay strategy, this method exhibited a high specificity for H9N2 among other influenza A virions such as H1N1 and H3N2. Under the optimized conditions, this method could detect as low as 0.63 ng mL- 1 H9N2 virions with the linear range of 2-400 ng mL- 1, the relative standard deviation for seven replicate detections of H9N2 virions was 7.2% (c = 10 ng mL- 1). The developed method was applied for the detection of H9N2 virions in real-world chicken dung samples, and the recovery for the spiking samples was 91.4-116.9%. This method is simple, rapid, sensitive, selective, reliable and has a good application potential for virions detection in real-world samples.

  2. SNG-logs at Skjern

    DEFF Research Database (Denmark)

    Korsbech, Uffe C C; Petersen, Jesper; Aage, Helle Karina

    1998-01-01

    Spectral Natural Gamma-ray logs have been run in two water supply borings at Skjern. The log data have been examined by a new technique - Noise Adjusted Singular Value Decomposition - in order to get a detailed and reliable picture of the distribution of uranium and thorium gamma-rays from heavy...

  3. Practicing induction:

    DEFF Research Database (Denmark)

    Sprogøe, Jonas; Rohde, Nicolas

    2009-01-01

    We claim that induction potentially triggers both individual and organizational learning and by drawing on practice-based theory we discuss how the interplay between individual and organization, what we call a generative dance, ignites both kinds of learning.......We claim that induction potentially triggers both individual and organizational learning and by drawing on practice-based theory we discuss how the interplay between individual and organization, what we call a generative dance, ignites both kinds of learning....

  4. Application of oil-field well log interpretation techniques to the Cerro Prieto Geothermal Field

    Energy Technology Data Exchange (ETDEWEB)

    Ershaghi, I.; Phillips, L.B.; Dougherty, E.L.; Handy, L.L.

    1979-10-01

    An example is presented of the application of oil-field techniques to the Cerro Prieto Field, Mexico. The lithology in this field (sand-shale lithology) is relatively similar to oil-field systems. The study was undertaken as a part of the first series of case studies supported by the Geothermal Log Interpretation Program (GLIP) of the US Department of Energy. The suites of logs for individual wells were far from complete. This was partly because of adverse borehole conditions but mostly because of unavailability of high-temperature tools. The most complete set of logs was a combination of Dual Induction Laterolog, Compensated Formation Density Gamma Ray, Compensated Neutron Log, and Saraband. Temperature data about the wells were sketchy, and the logs had been run under pre-cooled mud condition. A system of interpretation consisting of a combination of graphic and numerical studies was used to study the logs. From graphical studies, evidence of hydrothermal alteration may be established from the trend analysis of SP (self potential) and ILD (deep induction log). Furthermore, the cross plot techniques using data from density and neutron logs may help in establishing compaction as well as rock density profile with depth. In the numerical method, R/sub wa/ values from three different resistivity logs were computed and brought into agreement. From this approach, values of formation temperature and mud filtrate resistivity effective at the time of logging were established.

  5. Engineering aspects of radiometric logging

    International Nuclear Information System (INIS)

    Huppert, P.

    1982-01-01

    Engineering problems encountered in the development of nuclear borehole logging techniques are discussed. Spectrometric techniques require electronic stability of the equipment. In addition the electronics must be capable of handling high count rates of randomly distributed pulses of fast rise time from the detector and the systems must be designed so that precise calibration is possible under field operating conditions. Components of a logging system are discussed in detail. They include the logging probe (electronics, detector, high voltage supply, preamplifier), electronic instrumentation for data collection and processing and auxiliary equipment

  6. Log-balanced combinatorial sequences

    Directory of Open Access Journals (Sweden)

    Tomislav Došlic

    2005-01-01

    Full Text Available We consider log-convex sequences that satisfy an additional constraint imposed on their rate of growth. We call such sequences log-balanced. It is shown that all such sequences satisfy a pair of double inequalities. Sufficient conditions for log-balancedness are given for the case when the sequence satisfies a two- (or more- term linear recurrence. It is shown that many combinatorially interesting sequences belong to this class, and, as a consequence, that the above-mentioned double inequalities are valid for all of them.

  7. High current induction linacs

    International Nuclear Information System (INIS)

    Barletta, W.; Faltens, A.; Henestroza, E.; Lee, E.

    1994-07-01

    Induction linacs are among the most powerful accelerators in existence. They have accelerated electron bunches of several kiloamperes, and are being investigated as drivers for heavy ion driven inertial confinement fusion (HIF), which requires peak beam currents of kiloamperes and average beam powers of some tens of megawatts. The requirement for waste transmutation with an 800 MeV proton or deuteron beam with an average current of 50 mA and an average power of 40 MW lies midway between the electron machines and the heavy ion machines in overall difficulty. Much of the technology and understanding of beam physics carries over from the previous machines to the new requirements. The induction linac allows use of a very large beam aperture, which may turn out to be crucial to reducing beam loss and machine activation from the beam halo. The major issues addressed here are transport of high intensity beams, availability of sources, efficiency of acceleration, and the state of the needed technology for the waste treatment application. Because of the transformer-like action of an induction core and the accompanying magnetizing current, induction linacs make the most economic sense and have the highest efficiencies with large beam currents. Based on present understanding of beam transport limits, induction core magnetizing current requirements, and pulse modulators, the efficiencies could be very high. The study of beam transport at high intensities has been the major activity of the HIF community. Beam transport and sources are limiting at low energies but are not significant constraints at the higher energies. As will be shown, the proton beams will be space-charge-dominated, for which the emittance has only a minor effect on the overall beam diameter but does determine the density falloff at the beam edge

  8. MAGNET

    CERN Multimedia

    by B. Curé

    2011-01-01

    The magnet operation was very satisfactory till the technical stop at the end of the year 2010. The field was ramped down on 5th December 2010, following the successful regeneration test of the turbine filters at full field on 3rd December 2010. This will limit in the future the quantity of magnet cycles, as it is no longer necessary to ramp down the magnet for this type of intervention. This is made possible by the use of the spare liquid Helium volume to cool the magnet while turbines 1 and 2 are stopped, leaving only the third turbine in operation. This obviously requires full availability of the operators to supervise the operation, as it is not automated. The cryogenics was stopped on 6th December 2010 and the magnet was left without cooling until 18th January 2011, when the cryoplant operation resumed. The magnet temperature reached 93 K. The maintenance of the vacuum pumping was done immediately after the magnet stop, when the magnet was still at very low temperature. Only the vacuum pumping of the ma...

  9. VT Route Log Points 2017

    Data.gov (United States)

    Vermont Center for Geographic Information — This data layer is used with VTrans' Integrated Route Log System (IRA). It is also used to calibrate the linear referencing systems, including the End-to-End and...

  10. New materials for fireplace logs

    Science.gov (United States)

    Kieselback, D. J.; Smock, A. W.

    1971-01-01

    Fibrous insulation and refractory concrete are used for logs as well as fireproof walls, incinerator bricks, planters, and roof shingles. Insulation is lighter and more shock resistant than fireclay. Lightweight slag bonded with refractory concrete serves as aggregrate.

  11. Overview of Bearingless Induction Motors

    Directory of Open Access Journals (Sweden)

    Xiaodong Sun

    2014-01-01

    Full Text Available Bearingless induction motors combining functions of both torque generation and noncontact magnetic suspension together have attracted more and more attention in the past decades due to their definite advantages of compactness, simple structure, less maintenance, no wear particles, high rotational speed, and so forth. This paper overviews the key technologies of the bearingless induction motors, with emphasis on motor topologies, mathematical models, and control strategies. Particularly, in the control issues, the vector control, independent control, direct torque control, nonlinear decoupling control, sensorless control, and so forth are investigated. In addition, several possible development trends of the bearingless induction motors are also discussed.

  12. Palm distributions for log Gaussian Cox processes

    DEFF Research Database (Denmark)

    Coeurjolly, Jean-Francois; Møller, Jesper; Waagepetersen, Rasmus Plenge

    2017-01-01

    This paper establishes a remarkable result regarding Palm distributions for a log Gaussian Cox process: the reduced Palm distribution for a log Gaussian Cox process is itself a log Gaussian Cox process that only differs from the original log Gaussian Cox process in the intensity function. This new...... result is used to study functional summaries for log Gaussian Cox processes....

  13. Selenium speciation in radix puerariae using ultrasonic assisted extraction combined with reversed phase high performance liquid chromatography-inductively coupled plasma-mass spectrometry after magnetic solid-phase extraction with 5-sulfosalicylic acid functionalized magnetic nanoparticles

    Science.gov (United States)

    Cao, Yupin; Yan, Lizhen; Huang, Hongli; Deng, Biyang

    2016-08-01

    A new method for determination of selenium species in radix puerariae was described. The method consists of sample enrichment with 5-sulfosalicylic acid (SSA)-functionalized silica-coated magnetic nanoparticles (SMNPs), high performance liquid chromatography (HPLC) separation, and online detection using inductively coupled plasma mass spectrometry (ICP-MS). The selenium species were extracted using ultrasonic extraction system with a mixture of protease K and lipase. The SSA-SMNPs were used to enrich trace amounts of selenite [Se(IV)], selenate [Se(VI)], selenomethionine (SeMet), and selenocystine (SeCys2) from lower selenium containing samples. Under the optimal conditions, the limits of detection (3σ) for SeCys2, Se(IV), SeMet and Se(VI) were observed as 0.0023, 0.0015, 0.0043, and 0.0016 ng mL- 1, respectively. The RSD values (n = 6) of method for intraday were observed between 0.5% and 0.9%. The RSD values of method for interday were less than 1.3%. The linear concentration ranges for SeCys2, Se(IV), SeMet and Se(VI) were 0.008-1000, 0.005-200, 0.015-500 and 0.006-200 ng mL- 1, respectively. The detection limits of this method were improved by 10 times due to the enrichment with the SSA-SMNP extraction. The contents of SeCys2, Se(IV), SeMet, and Se(VI) in radix puerariae were determined as 0.0140, 0.171, 0.0178, and 0.0344 μg g- 1, respectively. The recoveries were in the range of 95.6%-99.4% and the RSDs (n = 6) of recoveries were less than 1.5%.

  14. Lithostratigraphy from downhole logs in Hole AND-1B, Antarctica

    Science.gov (United States)

    Williams, Trevor; Morin, Roger H.; Jarrard, Richard D.; Jackolski, Chris L.; Henrys, Stuart A.; Niessen, Frank; Magens, Diana; Kuhn, Gerhard; Monien, Donata; Powell, Ross D.

    2012-01-01

    The ANDRILL (Antarctic Drilling Project) McMurdo Ice Shelf (MIS) project drilled 1285 m of sediment in Hole AND–1B, representing the past 12 m.y. of glacial history. Downhole geophysical logs were acquired to a depth of 1018 mbsf (meters below seafloor), and are complementary to data acquired from the core. The natural gamma radiation (NGR) and magnetic susceptibility logs are particularly useful for understanding lithological and paleoenvironmental change at ANDRILL McMurdo Ice Shelf Hole AND–1B. NGR logs cover the entire interval from the seafloor to 1018 mbsf, and magnetic susceptibility and other logs covered the open hole intervals between 692 and 1018 and 237–342 mbsf. In the upper part of AND–1B, clear alternations between low and high NGR values distinguish between diatomite (lacking minerals containing naturally radioactive K, U, and Th) and diamictite (containing K-bearing clays, K-feldspar, mica, and heavy minerals). In the lower open hole logged section, NGR and magnetic susceptibility can also distinguish claystones (rich in K-bearing clay minerals, relatively low in magnetite) and diamictites (relatively high in magnetite). Sandstones can be distinguished by their high resistivity values in AND–1B. On the basis of these three downhole logs, diamictite, claystones, and sandstones can be predicted correctly for 74% of the 692–1018 mbsf interval. The logs were then used to predict facies for the 6% of this interval that was unrecovered by coring. Given the understanding of the physical property characteristics of different facies, it is also possible to identify subtle changes in lithology from the physical properties and help refine parts of the lithostratigraphy, for example, the varying terrigenous content of diatomites and the transitions from subice diamictite to open-water diatomite.

  15. Log quality enhancement: A systematic assessment of logging company wellsite performance and log quality

    International Nuclear Information System (INIS)

    Farnan, R.A.; Mc Hattie, C.M.

    1984-01-01

    To improve the monitoring of logging company performance, computer programs were developed to assess information en masse from log quality check lists completed on wellsite by the service company engineer and Phillips representative. A study of all logging jobs performed by different service companies for Phillips in Oklahoma (panhandle excepted) during 1982 enabled several pertinent and beneficial interpretations to be made. Company A provided the best tool and crew service. Company B incurred an excessive amount of lost time related to tool failure, in particular the neutron-density tool combination. Company C, although used only three times, incurred no lost time. With a reasonable data base valid conclusions were made pertaining, for example, to repeated tool malfunctions. The actual logs were then assessed for quality

  16. Induction practice -

    DEFF Research Database (Denmark)

    Rohde, Nicolas; Sprogøe, Jonas

    2007-01-01

    that induction potentially triggers both individual and organizational learning and by drawing on practice-based theory we discuss how the interplay between individual and the organization, what we call agenerative dance, ignites both kinds of learning. We focus on and describe the interplay , ignites both kinds...

  17. Validation of an internal hardwood log defect prediction model

    Science.gov (United States)

    R. Edward. Thomas

    2011-01-01

    The type, size, and location of internal defects dictate the grade and value of lumber sawn from hardwood logs. However, acquiring internal defect knowledge with x-ray/computed-tomography or magnetic-resonance imaging technology can be expensive both in time and cost. An alternative approach uses prediction models based on correlations among external defect indicators...

  18. Application of MRIL-WD (Magnetic Resonance Imaging Logging While Drilling) for irreducible water saturation, total reservoir, free-fluid, bound-fluid porosity measurements and its value for the petrophysical analysis of RT/RM data from the Shah Deniz well

    Science.gov (United States)

    Amirov, Elnur

    2016-04-01

    Sperry-Sun (Sperry Drilling Services) is the leader in MWD/LWD reliability, has developed the industry's first LWD NMR/MRIL-WD (nuclear magnetic resonance) tool. The MRIL-WD (magnetic resonance imaging logging-while-drilling) service directly measures the T1 component of hydrogen in subsurface rock units while drilling to obtain total reservoir porosity and to dissect the observed total porosity into its respective components of free fluid and bound fluid porosity. These T1 data are used to secure accurate total, free-fluid, capillary-bound water, and clay-bound water porosity of the reservoir sections which can be drilled in the several Runs. Over the last decade, results from Magnetic Resonance Imaging logs (NMR) have added significant value to petrophysical analysis and understanding by providing total, free-fluid and bound-fluid porosities, combined with fluid typing capabilities. With MRIL-WD very valuable Real-Time or Recorded Memory data/information is now available during or shortly after the drilling operation (formation properties measurement can be taken right after a drill bit penetration), while trip in and trip out as well. A key point in utilizing MRIL in an LWD environment is motion-tolerant measurements. Recent MRIL-WD logging runs from the Shah Deniz wells located in the Khazarian-Caspian Sea of the Azerbaijan Republic helped to delineate and assess hydrocarbon bearing zones. Acquired results demonstrate how MRIL data can be acquired while-drilling and provide reliable/high quality measurements. Magnetic Resonance Imaging logs at some developments wells have become a cornerstone in formation evaluation and petrophysical understanding. By providing total, free-fluid, and bound-fluid porosities together with fluid typing, MRIL results have significantly added to the assessment of reservoirs. In order to reduce NPT (Non-Productive Time) and save the rig operations time, there is always the desire to obtain logging results as soon as possible

  19. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet was energised at the beginning of March 2012 at a low current to check all the MSS safety chains. Then the magnet was ramped up to 3.8 T on 6 March 2012. Unfortunately two days later an unintentional switch OFF of the power converter caused a slow dump. This was due to a misunderstanding of the CCC (CERN Control Centre) concerning the procedure to apply for the CMS converter control according to the beam-mode status at that time. Following this event, the third one since 2009, a discussion was initiated to define possible improvement, not only on software and procedures in the CCC, but also to evaluate the possibility to upgrade the CMS hardware to prevent such discharge from occurring because of incorrect procedure implementations. The magnet operation itself was smooth, and no power cuts took place. As a result, the number of magnetic cycles was reduced to the minimum, with only two full magnetic cycles from 0 T to 3.8 T. Nevertheless the magnet suffered four stops of the cryogeni...

  20. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      Following the unexpected magnet stops last August due to sequences of unfortunate events on the services and cryogenics [see CMS internal report], a few more events and initiatives again disrupted the magnet operation. All the magnet parameters stayed at their nominal values during this period without any fault or alarm on the magnet control and safety systems. The magnet was stopped for the September technical stop to allow interventions in the experimental cavern on the detector services. On 1 October, to prepare the transfer of the liquid nitrogen tank on its new location, several control cables had to be removed. One cable was cut mistakenly, causing a digital input card to switch off, resulting in a cold-box (CB) stop. This tank is used for the pre-cooling of the magnet from room temperature down to 80 K, and for this reason it is controlled through the cryogenics control system. Since the connection of the CB was only allowed for a field below 2 T to avoid the risk of triggering a fast d...

  1. Pulsed neutron generator for logging

    International Nuclear Information System (INIS)

    Thibideau, F.D.

    1977-01-01

    A pulsed neutron generator for uranium logging is described. This generator is one component of a prototype uranium logging probe which is being developed by SLA to detect, and assay, uranium by borehole logging. The logging method is based on the measurement of epithermal neutrons resulting from the prompt fissioning of uranium from a pulsed source of 17.6 MeV neutrons. An objective of the prototype probe was that its diameter not exceed 2.75 inches, which would allow its use in conventional rotary drill holes of 4.75-inch diameter. This restriction limited the generator to a maximum 2.375-inch diameter. The performance requirements for the neutron generator specified that it operate with a nominal output of 5 x 10 6 neutrons/pulse at up to 100 pulses/second for a one-hour period. The development of a neutron generator meeting the preliminary design goals was completed and two prototype models were delivered to SLA. These two generators have been used by SLA to log a number of boreholes in field evaluation of the probe. The results of the field evaluations have led to the recommendation of several changes to improve the probe's operation. Some of these changes will require additional development effort on the neutron generator. It is expected that this work will be performed during 1977. The design and operation of the first prototype neutron generators is described

  2. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet and its sub-systems were stopped at the beginning of the winter shutdown on 8th December 2011. The magnet was left without cooling during the cryogenics maintenance until 17th January 2012, when the cryoplant operation resumed. The magnet temperature reached 93 K. The vacuum pumping was maintained during this period. During this shutdown, the yearly maintenance was performed on the cryogenics, the vacuum pumps, the magnet control and safety systems, and the power converter and discharge lines. Several preventive actions led to the replacement of the electrovalve command coils, and the 20A DC power supplies of the magnet control system. The filters were cleaned on the demineralised water circuits. The oil of the diffusion pumps was changed. On the cryogenics, warm nitrogen at 343 K was circulated in the cold box to regenerate the filters and the heat exchangers. The coalescing filters have been replaced at the inlet of both the turbines and the lubricant trapping unit. The active cha...

  3. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

      The magnet was operated without any problem until the end of the LHC run in February 2013, apart from a CERN-wide power glitch on 10 January 2013 that affected the CMS refrigerator, causing a ramp down to 2 T in order to reconnect the coldbox. Another CERN-wide power glitch on 15 January 2013 didn’t affect the magnet subsystems, the cryoplant or the power converter. At the end of the magnet run, the reconnection of the coldbox at 2.5 T was tested. The process will be updated, in particular the parameters of some PID valve controllers. The helium flow of the current leads was reduced but only for a few seconds. The exercise will be repeated with the revised parameters to validate the automatic reconnection process of the coldbox. During LS1, the water-cooling services will be reduced and many interventions are planned on the electrical services. Therefore, the magnet cryogenics and subsystems will be stopped for several months, and the magnet cannot be kept cold. In order to avoid unc...

  4. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet was successfully operated at the end of the year 2009 despite some technical problems on the cryogenics. The magnet was ramped up to 3.8 T at the end of November until December 16th when the shutdown started. The magnet operation met a few unexpected stops. The field was reduced to 3.5 T for about 5 hours on December 3rd due to a faulty pressure sensor on the helium compressor. The following day the CERN CCC stopped unintentionally the power converters of the LHC and the experiments, triggering a ramp down that was stopped at 2.7 T. The magnet was back at 3.8 T about 6 hours after CCC sent the CERN-wide command. Three days later, a slow dump was triggered due to a stop of the pump feeding the power converter water-cooling circuit, during an intervention on the water-cooling plant done after several disturbances on the electrical distribution network. The magnet was back at 3.8 T in the evening the same day. On December 10th a break occurred in one turbine of the cold box producing the liquid ...

  5. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The CMS magnet has been running steadily and smoothly since the summer, with no detected flaw. The magnet instrumentation is entirely operational and all the parameters are at their nominal values. Three power cuts on the electrical network affected the magnet run in the past five months, with no impact on the data-taking as the accelerator was also affected at the same time. On 22nd June, a thunderstorm caused a power glitch on the service electrical network. The primary water cooling at Point 5 was stopped. Despite a quick restart of the water cooling, the inlet temperature of the demineralised water on the busbar cooling circuit increased by 5 °C, up to 23.3 °C. It was kept below the threshold of 27 °C by switching off other cooling circuits to avoid the trigger of a slow dump of the magnet. The cold box of the cryogenics also stopped. Part of the spare liquid helium volume was used to maintain the cooling of the magnet at 4.5 K. The operators of the cryogenics quickly restarted ...

  6. Hardwood log grades and lumber grade yields for factory lumber logs

    Science.gov (United States)

    Leland F. Hanks; Glenn L. Gammon; Robert L. Brisbin; Everette D. Rast

    1980-01-01

    The USDA Forest Service Standard Grades for Hardwood Factory Lumber Logs are described, and lumber grade yields for 16 species and 2 species groups are presented by log grade and log diameter. The grades enable foresters, log buyers, and log sellers to select and grade those log suitable for conversion into standard factory grade lumber. By using the apropriate lumber...

  7. The log S -log N distribution of gamma ray brust

    International Nuclear Information System (INIS)

    Yamagami, Takamasa; Nishimura, Jun; Fujii, Masami

    1982-01-01

    The relation between the size S and the frequency N of gamma ray burst has been studied. This relation may be determined from the celestial distribution of gamma ray burst sources. The present analysis gives that the log S - log N relation for any direction is determined by the celestial distribution of gamma ray burst sources. The observed bursts were analyzed. The celestial distribution of gamma ray burst sources was observed by the satellites of USSR. The results showed that the distribution seemed to be isotropic. However, the calculated log S - log N relation based on the isotropic distribution wasF in disagreement with the observed ones. As the result of analysis, it was found that the observed bursts missed low energy part because of the threshold of detectors. The levels of discrimination of detection were not clear. When a proper threshold level is set for each type of burst, and the size of bursts is determined, the above mentioned discrepancy will be deleted regardless of luminosity and the spatial distribution of bursts. (Kato, T.)

  8. Mud Logging; Control geologico en perforaciones petroliferas (Mud Logging)

    Energy Technology Data Exchange (ETDEWEB)

    Pumarega Lafuente, J.C.

    1994-12-31

    Mud Logging is an important activity in the oil field and it is a key job in drilling operations, our duties are the acquisition, collection and interpretation of the geological and engineering data at the wellsite, also inform the client immediately of any significant changes in the well. (Author)

  9. Borehole logging for uranium exploration

    International Nuclear Information System (INIS)

    1982-01-01

    The present text has been prepared taking into account the requirements of both developing countries, which might be at an incipient stage of uranium exploration, and industrialized countries, where more advanced exploration and resource evaluation techniques are commonly in use. While it was felt necessary to include some discussion of exploration concepts and fundamental physical principles underlying various logging methods, it was not the intention of the consultants to provide a thorough, detailed explanation of the various techniques, or even to give a comprehensive listing thereof. However, a list of references has been included, and it is strongly recommended that the serious student of mineral logging consult this list for further guidance

  10. Pulsed neutron porosity logging system

    International Nuclear Information System (INIS)

    Smith, H.D. Jr.; Smith, M.P.; Schultz, W.E.

    1978-01-01

    An improved pulsed neutron porosity logging system is provided in the present invention. A logging tool provided with a 14 MeV pulsed neutron source, an epithermal neutron detector, and a fast neutron detector is moved through a borehole. Repetitive bursts of neutrons irradiate the earth formations and, during the bursts, the fast neutron population is sampled. During the interval between bursts the epithermal neutron population is sampled along with background gamma radiation due to lingering thermal neutrons. The fast and epithermal neutron population measurements are combined to provide a measurement of formation porosity

  11. 3D Analysis of Coupled Quasi-Stationary Electromagnetic and Non-Stationary Temperature Fields in Non-Magnetic Inductively Heated Charge

    Czech Academy of Sciences Publication Activity Database

    Barglik, J.; Doležel, Ivo; Šolín, Pavel; Ulrych, B.

    2001-01-01

    Roč. 97, č. 885 (2001), s. 9-16 ISSN 0072-4688 R&D Projects: GA ČR GA102/01/0184; GA MŠk ME 448 Grant - others:-(PL) 7T08603716 Keywords : induction heating * numerical analysis * integral model Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  12. Combined Approach for Solving the Electromagnetic Induction ...

    African Journals Online (AJOL)

    Nafiisah

    boundary. For example, in electromagnetic induction imaging, it is the magnetic ... Applications of electromagnetic .... The first integral is referred to as a single layer potential and is continuous across ..... Scattering Theory, 2nd ed., Springer.

  13. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The magnet ran smoothly in the last few months until a fast dump occurred on 9th May 2011. Fortunately, this occurred in the afternoon of the first day of the technical stop. The fast dump was due to a valve position controller that caused the sudden closure of a valve. This valve is used to regulate the helium flow on one of the two current leads, which electrically connects the coil at 4.5 K to the busbars at room temperature. With no helium flow on the lead, the voltage drop and the temperatures across the leads increase up to the defined thresholds, triggering a fast dump through the Magnet Safety System (MSS). The automatic reaction triggered by the MSS worked properly. The helium release was limited as the pressure rise was just at the limit of the safety valve opening pressure. The average temperature of the magnet reached 72 K. It took four days to recover the temperature and refill the helium volumes. The faulty valve controller was replaced by a spare one before the magnet ramp-up resumed....

  14. Logging Work Injuries in Appalachia

    Science.gov (United States)

    Charles H. Wolf; Gilbert P. Dempsey

    1978-01-01

    Logging accidents are costly. They may bring pain to injured workers, hardship to their families, and higher insurance premiums and lower productivity to their employers. Our analysis of 1,172 injuries in central Appalachia reveals that nearly half of all time lost-and almost all fatalities-resulted from accidents during felling and unloading. The largest proportion of...

  15. Log files for testing usability

    NARCIS (Netherlands)

    Klein Teeselink, G.; Siepe, A.H.M.; Pijper, de J.R.

    1999-01-01

    The aim of this study is to gain insight in the usefulness of log file analysis as a method to evaluate the usability of individual interface components and their influence on the usability of the overall user interface. We selected a music player as application, with four different interfaces and

  16. Electromagnetic induction phenomena in plasma systems

    International Nuclear Information System (INIS)

    Karlovitz, B.

    1982-01-01

    The phenomenon of electromagnetic induction is considered in complex high temperature plasma systems. Thermal energy of such fully ionized plasma is really energy of the magnetic vortex fields surrounding the randomly moving ions and electrons. In an expanding plasma stream, moving across the containing magnetic field, random thermal motion of the ions and electrons is converted into ordered motion and thereby random magnetic energy of the plasma into magnetic energy of an ordered field. Consequently, in contrast to simple systems consisting of coils and magnets only, an expanding plasma stream can maintain net outflow of ordered magnetic energy from a closed volume for an indefinite length of time. Conversion of thermal energy of plasma into ordered magnetic energy by the thermodynamic expansion process leads to the expectation of a new induction phenomenon: the generation of a unidirectional induced electromotive force of unlimited duration, measured in a closed loop at rest relative to the magnetic field, by the expansion work of the plasma stream. No change is required in the differential form of Maxwell's equations for the existence of this induction phenomenon, only the definition of the concept of rate of change of magnetic flux needs to be modified in the macroscopic equations to correspond to the rate of flow of magnetic energy across a closed surface. An experimental test of the predicted induction phenomenon is proposed

  17. Hardwood log supply: a broader perspective

    Science.gov (United States)

    Iris Montague; Adri Andersch; Jan Wiedenbeck; Urs. Buehlmann

    2015-01-01

    At regional and state meetings we talk with others in our business about the problems we face: log exports, log quality, log markets, logger shortages, cash flow problems, the weather. These are familiar talking points and real and persistent problems. But what is the relative importance of these problems for log procurement in different regions of...

  18. Unsupervised signature extraction from forensic logs

    NARCIS (Netherlands)

    Thaler, S.M.; Menkovski, V.; Petkovic, M.; Altun, Y.; Das, K.; Mielikäinen, T.; Malerba, D.; Stefanowski, J.; Read, J.; Žitnik, M.; Ceci, M.

    2017-01-01

    Signature extraction is a key part of forensic log analysis. It involves recognizing patterns in log lines such that log lines that originated from the same line of code are grouped together. A log signature consists of immutable parts and mutable parts. The immutable parts define the signature, and

  19. A method of estimating log weights.

    Science.gov (United States)

    Charles N. Mann; Hilton H. Lysons

    1972-01-01

    This paper presents a practical method of estimating the weights of logs before they are yarded. Knowledge of log weights is required to achieve optimum loading of modern yarding equipment. Truckloads of logs are weighed and measured to obtain a local density index (pounds per cubic foot) for a species of logs. The density index is then used to estimate the weights of...

  20. Nondestructive evaluation for sorting red maple logs

    Science.gov (United States)

    Xiping Wang; Robert J. Ross; David W. Green; Karl Englund; Michael Wolcott

    2000-01-01

    Existing log grading procedures in the United States make only visual assessments of log quality. These procedures do not incorporate estimates of the modulus of elasticity (MOE) of logs. It is questionable whether the visual grading procedures currently used for logs adequately assess the potential quality of structural products manufactured from them, especially...

  1. Nuclear well logging in hydrology

    International Nuclear Information System (INIS)

    1971-01-01

    The optimum development of regional and local groundwater resources requires a quantitative evaluation of its aquifers and aquicludes, and of the physical and chemical properties relevant to the recharge to and withdrawal of water from them. If an understanding of the groundwater regime is to be obtained, geological observations at outcrop must be augmented by subsurface measurements of the strata and the waters they contain. Measurements of many hydrological and geological parameters can be made in situ by nuclear geophysical well-logging methods. Very simply, well logging consists of lowering a measuring probe into a well and making a continuous record of the variations of a particular parameter with depth. In most circumstances, repetition of the measurements under differing hydrodynamic conditions results in a better definition of the flow regime in the aquifer. Nuclear well-logging techniques have for some years been capable of solving a number of the sub-surface measurement problems faced by hydrogeologists. However, the present usage of these methods varies from country to country and the literature concerning applications is scattered in the professional journals of several disciplines. The objective of this report is to include in a single reference volume descriptions of the physical principles of nuclear logging methods, their applications to hydrogeological problems and their limitations on a level suitable for the practising hydrologists with a limited knowledge of nuclear physics. The Working Group responsible for compiling the report recommended that it should cover a broad spectrum of hydrogeological investigations and problems. For example, it saw no valid reason to distinguish for the purposes of the report between well-logging applications for water-supply purposes and for water-flooding studies in the petroleum industry. Neutron measurements made for soil-moisture determinations in the unsaturated zone have been specifically omitted, however, as

  2. Predicting internal red oak (Quercus rubra) log defect features using surface defect defect measurements

    Science.gov (United States)

    R. Edward. Thomas

    2013-01-01

    Determining the defects located within a log is crucial to understanding the tree/log resource for efficient processing. However, existing means of doing this non-destructively requires the use of expensive x-ray/CT (computerized tomography), MRI (magnetic resonance imaging), or microwave technology. These methods do not lend themselves to fast, efficient, and cost-...

  3. Log analysis in the shallow oil sands of the San Joaquin Valley, California

    International Nuclear Information System (INIS)

    Vohs, J.B.

    1976-01-01

    Many fields in the San Joaquin Valley of California produce oil from a depth of 2,500 ft or less. During the period of primary production in these fields, evaluation of potential pay intervals from logs was restricted to examination of ES logs and correlation. With the introduction of secondary and tertiary recovery techniques the need for more and better answers, more quickly available, became apparent. However, several log-analysis problems had to be resolved. Formation evaluation using well logs was complicated by the shaliness of the sand intervals, the low and variable salinity of the formation waters, and the presence of low-pressure-gas (depleted) zones in many of the shallow sands. Solutions to these problems have required more modern logging programs and interpretation techniques. Logs available for the evaluation of these sands are the dual induction-laterolog, the compensated formation density log, the compensated neutron log, and the microlaterolog or proximity log. With this suite of logs it is possible to determine the shale content, porosity, saturation in the flushed zone, and water saturation of the sand, and to locate the low-pressure-gas sands and depleted zones. In cases where freshwater and oil are interlayered, it is possible to tell which sands contain oil and which contain only water. Because a quick interpretation is required, wellsite techniques are called for. These will be described

  4. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet worked very well at 3.8 T as expected, despite a technical issue that manifested twice in the cryogenics since June. All the other magnet sub-systems worked without flaw. The issue in the cryogenics was with the cold box: it could be observed that the cold box was getting progressively blocked, due to some residual humidity and air accumulating in the first thermal exchanger and in the adsorber at 65 K. This was later confirmed by the analysis during the regeneration phases. An increase in the temperature difference between the helium inlet and outlet across the heat exchanger and a pressure drop increase on the filter of the adsorber were observed. The consequence was a reduction of the helium flow, first compensated by the automatic opening of the regulation valves. But once they were fully opened, the flow and refrigeration power reduced as a consequence. In such a situation, the liquid helium level in the helium Dewar decreased, eventually causing a ramp down of the magnet current and a field...

  5. MAGNET

    CERN Multimedia

    B. Curé

    MAGNET During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bough...

  6. MAGNET

    CERN Multimedia

    Benoit Curé.

    The magnet operation restarted end of June this year. Quick routine checks of the magnet sub-systems were performed at low current before starting the ramps up to higher field. It appeared clearly that the end of the field ramp down to zero was too long to be compatible with the detector commissioning and operations plans. It was decided to perform an upgrade to keep the ramp down from 3.8T to zero within 4 hours. On July 10th, when a field of 1.5T was reached, small movements were observed in the forward region support table and it was decided to fix this problem before going to higher field. At the end of July the ramps could be resumed. On July 28th, the field was at 3.8T and the summer CRAFT exercise could start. This run in August went smoothly until a general CERN wide power cut took place on August 3rd, due to an insulation fault on the high voltage network outside point 5. It affected the magnet powering electrical circuit, as it caused the opening of the main circuit breakers, resulting in a fast du...

  7. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

    The magnet is fully stopped and at room temperature. The maintenance works and consolidation activities on the magnet sub-systems are progressing. To consolidate the cryogenic installation, two redundant helium compressors will be installed as ‘hot spares’, to avoid the risk of a magnet downtime in case of a major failure of a compressor unit during operation. The screw compressors, their motors, the mechanical couplings and the concrete blocks are already available and stored at P5. The metallic structure used to access the existing compressors in SH5 will be modified to allow the installation of the two redundant ones. The plan is to finish the installation and commissioning of the hot spare compressors before the summer 2014. In the meantime, a bypass on the high-pressure helium piping will be installed for the connection of a helium drier unit later during the Long Shutdown 1, keeping this installation out of the schedule critical path. A proposal is now being prepared for the con...

  8. Uranium logging in earth formations

    International Nuclear Information System (INIS)

    Givens, W.W.

    1979-01-01

    A technique is provided for assaying the formations surrounding a borehole for uranium. A borehole logging tool cyclically irradiates the formations with neutrons and responds to neutron fluxes produced during the period of time that prompt neutrons are being produced by the neutron fission of uranium in the formations. A borehole calibration tool employs a steady-state (continuous output) neutron source, firstly, to produce a response to neutron fluxes in models having known concentrations of uranium and, secondly, to to produce a response to neutron fluxes in the formations surrounding the borehole. The neutron flux responses of the borehole calibration tool in both the model and the formations surrounding the borehole are utilized to correct the neutron flux response of the borehole logging tool for the effects of epithermal/thermal neutron moderation, scattering, and absorption within the borehole itself

  9. Logística empresarial

    OpenAIRE

    Feres Sahid

    1987-01-01

    RESUMEN El concepto logístico, se pudo ver reflejado con exactitud desde el punto de vista etimológico e histórico a través de la revista de la E.A.N; ya que  tiene cierto carácter militar que lo hace característico a la gestión empresarial y de esto se formula un debate definitivo de este concepto.

  10. Chemical logging of geothermal wells

    Science.gov (United States)

    Allen, C.A.; McAtee, R.E.

    The presence of geothermal aquifers can be detected while drilling in geothermal formations by maintaining a chemical log of the ratio of the concentrations of calcium to carbonate and bicarbonate ions in the return drilling fluid. A continuous increase in the ratio of the concentrations of calcium to carbonate and bicarbonate ions is indicative of the existence of a warm or hot geothermal aquifer at some increased depth.

  11. Audit Log for Forensic Photography

    Science.gov (United States)

    Neville, Timothy; Sorell, Matthew

    We propose an architecture for an audit log system for forensic photography, which ensures that the chain of evidence of a photograph taken by a photographer at a crime scene is maintained from the point of image capture to its end application at trial. The requirements for such a system are specified and the results of experiments are presented which demonstrate the feasibility of the proposed approach.

  12. Logística empresarial

    Directory of Open Access Journals (Sweden)

    Feres Sahid

    1987-04-01

    Full Text Available RESUMEN El concepto logístico, se pudo ver reflejado con exactitud desde el punto de vista etimológico e histórico a través de la revista de la E.A.N; ya que  tiene cierto carácter militar que lo hace característico a la gestión empresarial y de esto se formula un debate definitivo de este concepto.

  13. Neutron capture in borehole logging

    International Nuclear Information System (INIS)

    Randall, R.R.

    1981-01-01

    The use is described of a pulsed source of fast neutrons and a radiation detector to measure the thermal neutron population decay rate in a well logging instrument. The macroscopic neutron absorption cross-section is calculated by taking the natural logarithm of the ratio of the detected radiation counts occurring within two measurement intervals of fixed duration and starting at a fixed time after a neutron burst. (U.K.)

  14. Borehole logging in uranium exploration

    International Nuclear Information System (INIS)

    Kulkarni, N.H.

    1992-01-01

    The ultimate objective of exploration by drilling as far as Atomic Minerals Division is concerned is to locate the ore zone in the subsurface, draw samples and analyze them for their metal content. The presence of the ore zone is also indicated by gamma-ray logging of the borehole. A gamma-ray detector is lowered in the borehole and precise depth and grade of the ore zone is established. This helps the geologist in correlating the ore horizon with the surface outcrop or the ore zone intercepted in adjoining boreholes and in deciding about further drilling and location of boreholes. Most commonly, total gamma measurements are made although some units capable of measuring the gamma-ray spectrum are also in use. It is possible to know if the mineralization is due to uranium without waiting for the laboratory results. The present write up gives a brief account of the principles, equipment and methods of borehole gamma-ray logging including density and self-potential logging. (author). 8 refs., 5 figs

  15. MAGNET

    CERN Multimedia

    Benoit Curé

    The magnet subsystems resumed operation early this spring. The vacuum pumping was restarted mid March, and the cryogenic power plant was restarted on March 30th. Three and a half weeks later, the magnet was at 4.5 K. The vacuum pumping system is performing well. One of the newly installed vacuum gauges had to be replaced at the end of the cool-down phase, as the values indicated were not coherent with the other pressure measurements. The correction had to be implemented quickly to be sure no helium leak could be at the origin of this anomaly. The pressure measurements have been stable and coherent since the change. The cryogenics worked well, and the cool-down went quite smoothly, without any particular difficulty. The automated start of the turbines had to be fine-tuned to get a smooth transition, as it was observed that the cooling power delivered by the turbines was slightly higher than needed, causing the cold box to stop automatically. This had no consequence as the cold box safety system acts to keep ...

  16. MAGNET

    CERN Multimedia

    B. Curé

    During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bought. Th...

  17. Dynamic Planar Convex Hull with Optimal Query Time and O(log n · log log n ) Update Time

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Jakob, Riko

    2000-01-01

    The dynamic maintenance of the convex hull of a set of points in the plane is one of the most important problems in computational geometry. We present a data structure supporting point insertions in amortized O(log n · log log log n) time, point deletions in amortized O(log n · log log n) time......, and various queries about the convex hull in optimal O(log n) worst-case time. The data structure requires O(n) space. Applications of the new dynamic convex hull data structure are improved deterministic algorithms for the k-level problem and the red-blue segment intersection problem where all red and all...

  18. A model of annular linear induction pumps

    Energy Technology Data Exchange (ETDEWEB)

    Momozaki, Yoichi [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-10-27

    The present work explains how the magnetic field and the induced current are obtained when the distributed coils are powered by a 3 phase power supply.  From the magnetic field and the induced current, the thrust and the induction losses in the pump can be calculated to estimate the pump performance.

  19. Validation of methods to measure uranium isotopes using magnetic sector mass spectrometry with inductively coupled plasma source; Validacion de metodos para medir isotopos de uranio usando espectrometria de masas de sector magnetico con fuente de plasma acoplado inductivamente

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez M, H. [Universidad del Centro de Mexico, Capitan Caldera 75, Col. Tequixquiapan, 78250 San Luis Potosi, SLP (Mexico); Rios L, M. J. [Universidad Autonoma de San Luis Potosi, Facultad de Enfermeria y Nutricion, Unidad de Posgrado, Av. Nino Artillero 130, 78210 San Luis Potosi, SLP (Mexico); Romero G, E. T., E-mail: hector.hernandez520@gmail.com [ININ, Departamento de Quimica, Laboratorio Forense Nuclear, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2017-10-15

    The mass spectrometry technique with inductively coupled plasma source (Icp-Ms) has been widely used to measure isotopic ratios of elements toxic to human health. Reason for which, in this work several measurement methods for the analysis of uranium isotopes in different matrices were implemented using magnetic sector mass spectrometry with inductively coupled plasma source (Icp-SFMS). Groundwater, sediment, soil and urine were the matrices analyzed, which were supplied by intercomparison tests conducted by the IAEA and Association for the Promotion of Quality Control of Medical Biology Analysis in Radio-toxicology. The procedures used in the treatment of soil, sediment and water samples were based on US EPA methods. In the case of the urine sample, the preparation was rapid (1:20 dilution). The average of the results obtained in yield of each matrix was 94, 71, 72 and 78% for water, urine, soil and sediment respectively. In addition, the precision in terms of standard relative deviation was less than 5% and the accuracy was less than 4%. In conclusion, the Icp-SFMS is a very sensitive technique for measuring isotopes of U in different matrices. However, careful tuning is necessary, especially in the mass regions of interest 234, 235 and 238 if an external quantification is considered using natural U solutions. (Author)

  20. Plasma internal inductance dynamics in a tokamak

    International Nuclear Information System (INIS)

    Romero, J.A.

    2010-01-01

    A lumped parameter model for tokamak plasma current and inductance time evolution as a function of plasma resistance, non-inductive current drive sources and boundary voltage or poloidal field coil current drive is presented. The model includes a novel formulation leading to exact equations for internal inductance and plasma current dynamics. Having in mind its application in a tokamak inductive control system, the model is expressed in state space form, the preferred choice for the design of control systems using modern control systems theory. The choice of system states allows many interesting physical quantities such as plasma current, inductance, magnetic energy, and resistive and inductive fluxes be made available as output equations. The model is derived from energy conservation theorem, and flux balance theorems, together with a first order approximation for flux diffusion dynamics. The validity of this approximation has been checked using experimental data from JET showing an excellent agreement.

  1. Data Mining of Network Logs

    Science.gov (United States)

    Collazo, Carlimar

    2011-01-01

    The statement of purpose is to analyze network monitoring logs to support the computer incident response team. Specifically, gain a clear understanding of the Uniform Resource Locator (URL) and its structure, and provide a way to breakdown a URL based on protocol, host name domain name, path, and other attributes. Finally, provide a method to perform data reduction by identifying the different types of advertisements shown on a webpage for incident data analysis. The procedures used for analysis and data reduction will be a computer program which would analyze the URL and identify and advertisement links from the actual content links.

  2. Neutron borehole logging correction technique

    International Nuclear Information System (INIS)

    Goldman, L.H.

    1978-01-01

    In accordance with an illustrative embodiment of the present invention, a method and apparatus is disclosed for logging earth formations traversed by a borehole in which an earth formation is irradiated with neutrons and gamma radiation produced thereby in the formation and in the borehole is detected. A sleeve or shield for capturing neutrons from the borehole and producing gamma radiation characteristic of that capture is provided to give an indication of the contribution of borehole capture events to the total detected gamma radiation. It is then possible to correct from those borehole effects the total detected gamma radiation and any earth formation parameters determined therefrom

  3. Benchmark neutron porosity log calculations

    International Nuclear Information System (INIS)

    Little, R.C.; Michael, M.; Verghese, K.; Gardner, R.P.

    1989-01-01

    Calculations have been made for a benchmark neutron porosity log problem with the general purpose Monte Carlo code MCNP and the specific purpose Monte Carlo code McDNL. For accuracy and timing comparison purposes the CRAY XMP and MicroVax II computers have been used with these codes. The CRAY has been used for an analog version of the MCNP code while the MicroVax II has been used for the optimized variance reduction versions of both codes. Results indicate that the two codes give the same results within calculated standard deviations. Comparisons are given and discussed for accuracy (precision) and computation times for the two codes

  4. 29 CFR 1918.88 - Log operations.

    Science.gov (United States)

    2010-07-01

    ...) SAFETY AND HEALTH REGULATIONS FOR LONGSHORING Handling Cargo § 1918.88 Log operations. (a) Working in..., the employer shall ensure that employees remain clear of areas where logs being dumped could strike...

  5. Artificial intelligence approach to interwell log correlation

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jong-Se [Korea Maritime University, Pusan(Korea); Kang, Joo Myung [Seoul National University, Seoul(Korea); Kim, Jung Whan [Korea National Oil Corp., Anyang(Korea)

    2000-04-30

    This paper describes a new approach to automated interwell log correlation using artificial intelligence and principal component analysis. The approach to correlate wire line logging data is on the basis of a large set of subjective rules that are intended to represent human logical processes. The data processed are mainly the qualitative information such as the characteristics of the shapes extracted along log traces. The apparent geologic zones are identified by pattern recognition for the specific characteristics of log trace collected as a set of objects by object oriented programming. The correlation of zones between wells is made by rule-based inference program. The reliable correlation can be established from the first principal component logs derived from both the important information around well bore and the largest common part of variances of all available well log data. Correlation with field log data shows that this approach can make interwell log correlation more reliable and accurate. (author). 6 refs., 7 figs.

  6. Face logging in Copenhagen Limestone, Denmark

    DEFF Research Database (Denmark)

    Jakobsen, Lisa; Foged, Niels Nielsen; Erichsen, Lars

    2015-01-01

    tunnel in Copenhagen more than 2.5 km face logs were made in 467 locations at underground stations, shafts, caverns and along bored tunnels. Over 160 geotechnical boreholes, many with geophysical logging were executed prior to construction works. The bedrock consists of Paleogene "Copenhagen limestone......The requirement for excavation support can be assessed from face logging. Face logs can also improve our knowledge of lithological and structural conditions within bedrock and supplement information from boreholes and geophysical logs. During the construction of 8 km metro tunnel and 4 km heating....... The induration degrees recorded in face logs and boreholes are compared and correlated. Distinct geophysical log markers are used to divide the limestone into three units. These marker horizons are correlated between face logs and geotechnical boreholes. A 3D model of the strength variations recorded within...

  7. Magnetic

    Science.gov (United States)

    Aboud, Essam; El-Masry, Nabil; Qaddah, Atef; Alqahtani, Faisal; Moufti, Mohammed R. H.

    2015-06-01

    The Rahat volcanic field represents one of the widely distributed Cenozoic volcanic fields across the western regions of the Arabian Peninsula. Its human significance stems from the fact that its northern fringes, where the historical eruption of 1256 A.D. took place, are very close to the holy city of Al-Madinah Al-Monawarah. In the present work, we analyzed aeromagnetic data from the northern part of Rahat volcanic field as well as carried out a ground gravity survey. A joint interpretation and inversion of gravity and magnetic data were used to estimate the thickness of the lava flows, delineate the subsurface structures of the study area, and estimate the depth to basement using various geophysical methods, such as Tilt Derivative, Euler Deconvolution and 2D modeling inversion. Results indicated that the thickness of the lava flows in the study area ranges between 100 m (above Sea Level) at the eastern and western boundaries of Rahat Volcanic field and getting deeper at the middle as 300-500 m. It also showed that, major structural trend is in the NW direction (Red Sea trend) with some minor trends in EW direction.

  8. MAGNET

    CERN Multimedia

    Benoit Curé

    The cooling down to the nominal temperature of 4.5 K was achieved at the beginning of August, in conjunction with the completion of the installation work of the connection between the power lines and the coil current leads. The temperature gradient on the first exchanger of the cold box is now kept within the nominal range. A leak of lubricant on a gasket of the helium compressor station installed at the surface was observed and several corrective actions were necessary to bring the situation back to normal. The compressor had to be refilled with lubricant and a regeneration of the filters and adsorbers was necessary. The coil cool down was resumed successfully, and the cryogenics is running since then with all parameters being nominal. Preliminary tests of the 20kA coil power supply were done earlier at full current through the discharge lines into the dump resistors, and with the powering busbars from USC5 to UXC5 without the magnet connected. On Monday evening August 25th, at 8pm, the final commissionin...

  9. MAGNET

    CERN Document Server

    B. Curé

    The first phase of the commissioning ended in August by a triggered fast dump at 3T. All parameters were nominal, and the temperature recovery down to 4.5K was carried out in two days by the cryogenics. In September, series of ramps were achieved up to 3 and finally 3.8T, while checking thoroughly the detectors in the forward region, measuring any movement of and around the HF. After the incident of the LHC accelerator on September 19th, corrective actions could be undertaken in the forward region. When all these displacements were fully characterized and repetitive, with no sign of increments in displacement at each field ramp, it was possible to start the CRAFT, Cosmic Run at Four Tesla (which was in fact at 3.8T). The magnet was ramped up to 18.16kA and the 3 week run went smoothly, with only 4 interruptions: due to the VIP visits on 21st October during the LHC inauguration day; a water leak on the cooling demineralized water circuit, about 1 l/min, that triggered a stop of the cooling pumps, and resulte...

  10. MAGNET

    CERN Multimedia

    Benoit Curé

    2013-01-01

    Maintenance work and consolidation activities on the magnet cryogenics and its power distribution are progressing according to the schedules. The manufacturing of the two new helium compressor frame units has started. The frame units support the valves, all the sensors and the compressors with their motors. This activity is subcontracted. The final installation and the commissioning at CERN are scheduled for March–April 2014. The overhauls of existing cryogenics equipment (compressors, motors) are in progress. The reassembly of the components shall start in early 2014. The helium drier, to be installed on the high-pressure helium piping, has been ordered and will be delivered in the first trimester of 2014. The power distribution for the helium compressors in SH5 on the 3.3kV network is progressing. The 3.3kV switches, between each compressor and its hot spare compressor, are being installed, together with the power cables for the new compressors. The 3.3kV electrical switchboards in SE5 will ...

  11. Selective logging in the Brazilian Amazon.

    Science.gov (United States)

    G. P. Asner; D. E. Knapp; E. N. Broadbent; P. J. C. Oliveira; M Keller; J. N. Silva

    2005-01-01

    Amazon deforestation has been measured by remote sensing for three decades. In comparison, selective logging has been mostly invisible to satellites. We developed a large-scale, high-resolution, automated remote-sensing analysis of selective logging in the top five timber-producing states of the Brazilian Amazon. Logged areas ranged from 12,075 to 19,823 square...

  12. Linking log quality with product performance

    Science.gov (United States)

    D. W. Green; Robert Ross

    1997-01-01

    In the United States, log grading procedures use visual assessment of defects, in relation to the log scaling diameter, to estimate the yield of lumber that maybe expected from the log. This procedure was satisfactory when structural grades were based only on defect size and location. In recent years, however, structural products have increasingly been graded using a...

  13. Selective logging and its relation to deforestation

    Science.gov (United States)

    Gregory P. Asner; Michael Keller; Marco Lentini; Frank Merry; Souza Jr. Carlos

    2009-01-01

    Selective logging is a major contributor to the social, economic, and ecological dynamics of Brazilian Amazonia. Logging activities have expanded from low-volume floodplain harvests in past centuries to high-volume operations today that take about 25 million m3 of wood from the forest each year. The most common high-impact conventional and often illegal logging...

  14. Pacific Rim log trade: determinants and trends.

    Science.gov (United States)

    Donald F. Flora; Andrea L. Anderson; Wendy J. McGinnls

    1991-01-01

    Pacific Rim trade in softwood logs amounts to about $3 billion annually, of which the U.S. share is about $2 billion. Log exporting is a significant part of the forest economy in the Pacific Northwest. The 10 major Pacific Rim log-trading client and competitor countries differ widely in their roles in trade and in their policies affecting the industry.

  15. Well logging radioactive detector assembly

    International Nuclear Information System (INIS)

    Osburn, T.D.

    1992-01-01

    This patent describes a well logging instrument of the type having a radioactive logging sub having a sealed chamber and have a radioactive source for emitting radioactive energy into the well formation, the instrument having a radioactive energy detector for detecting gamma rays resulting from the emission of the radioactive energy into the well formation, and means for pressing the sub against the well of the well, an improved Dewar flask for the detector. It comprises: an inner housing formed of titanium and containing the detector; an outer housing formed of titanium, having a cylindrical side wall surrounding the inner housing and separated by a clearance which is evacuated, the outer housing being located within the sealed chamber in the sub of the instrument; a window section formed in the side wall of the outer housing adjacent the detector and on a side of the side wall closest to the wall of the well when the sub is pressed against the wall of the well; and wherein the inner housing has a cylindrical side wall that is of lesser wall thickness than the wall thickness of the side wall of the outer housing other than in the window section

  16. Inductive circuit arrangements

    International Nuclear Information System (INIS)

    Mansfield, Peter; Coxon, R.J.

    1987-01-01

    A switched coil arrangement is connected in a bridge configuration of four switches S 1 , S 2 , S 3 and S 4 which are each shunted by diodes D 1 , D 2 , D 3 and D 4 so that current can flow in either direction through a coil L depending on the setting of the switches. A capacitor C is connected across the bridge through a switch S 5 to receive the inductive energy stored in coil L on breaking the current flow path through the coil. The electrostatic energy stored in capacitor C can then be used to supply current through the coil in the reverse direction either immediately or after a time delay. Coil L may be a superconductive coil. Losses in the circuit can be made up by a trickle charge of capacitor C from a separate supply V 2 . The device may be used in nuclear magnetic resonance imaging. (author)

  17. Well log characterization of natural gas-hydrates

    Science.gov (United States)

    Collett, Timothy S.; Lee, Myung W.

    2012-01-01

    In the last 25 years there have been significant advancements in the use of well-logging tools to acquire detailed information on the occurrence of gas hydrates in nature: whereas wireline electrical resistivity and acoustic logs were formerly used to identify gas-hydrate occurrences in wells drilled in Arctic permafrost environments, more advanced wireline and logging-while-drilling (LWD) tools are now routinely used to examine the petrophysical nature of gas-hydrate reservoirs and the distribution and concentration of gas hydrates within various complex reservoir systems. Resistivity- and acoustic-logging tools are the most widely used for estimating the gas-hydrate content (i.e., reservoir saturations) in various sediment types and geologic settings. Recent integrated sediment coring and well-log studies have confirmed that electrical-resistivity and acoustic-velocity data can yield accurate gas-hydrate saturations in sediment grain-supported (isotropic) systems such as sand reservoirs, but more advanced log-analysis models are required to characterize gas hydrate in fractured (anisotropic) reservoir systems. New well-logging tools designed to make directionally oriented acoustic and propagation-resistivity log measurements provide the data needed to analyze the acoustic and electrical anisotropic properties of both highly interbedded and fracture-dominated gas-hydrate reservoirs. Advancements in nuclear magnetic resonance (NMR) logging and wireline formation testing (WFT) also allow for the characterization of gas hydrate at the pore scale. Integrated NMR and formation testing studies from northern Canada and Alaska have yielded valuable insight into how gas hydrates are physically distributed in sediments and the occurrence and nature of pore fluids(i.e., free water along with clay- and capillary-bound water) in gas-hydrate-bearing reservoirs. Information on the distribution of gas hydrate at the pore scale has provided invaluable insight on the mechanisms

  18. Inductive shearing of drilling pipe

    Science.gov (United States)

    Ludtka, Gerard M.; Wilgen, John; Kisner, Roger; Mcintyre, Timothy

    2016-04-19

    Induction shearing may be used to cut a drillpipe at an undersea well. Electromagnetic rings may be built into a blow-out preventer (BOP) at the seafloor. The electromagnetic rings create a magnetic field through the drillpipe and may transfer sufficient energy to change the state of the metal drillpipe to shear the drillpipe. After shearing the drillpipe, the drillpipe may be sealed to prevent further leakage of well contents.

  19. The law of electromagnetic induction

    Directory of Open Access Journals (Sweden)

    V.J. Kutkovetskyy

    2014-09-01

    Full Text Available Mathematical models of the electromagnetic induction law which do not take into account Faraday’s restrictions are not in full accordance with the physical phenomenon and so they are not laws. Their incomplete correspondence with real devices results in such "paradoxes" as unlimited magnetic field of unipolar generators, infinite sizes of inductors for DC and AC machines modeled, and so on.

  20. Semi-automatic logarithmic converter of logs

    International Nuclear Information System (INIS)

    Gol'dman, Z.A.; Bondar's, V.V.

    1974-01-01

    Semi-automatic logarithmic converter of logging charts. An original semi-automatic converter was developed for use in converting BK resistance logging charts and the time interval, ΔT, of acoustic logs from a linear to a logarithmic scale with a specific ratio for subsequent combining of them with neutron-gamma logging charts in operative interpretation of logging materials by a normalization method. The converter can be used to increase productivity by giving curves different from those obtained in manual, pointwise processing. The equipment operates reliably and is simple in use. (author)

  1. A Universal Logging System for LHCb Online

    International Nuclear Information System (INIS)

    Nikolaidis, Fotis; Brarda, Loic; Garnier, Jean-Christophe; Neufeld, Niko

    2011-01-01

    A log is recording of system's activity, aimed to help system administrator to traceback an attack, find the causes of a malfunction and generally with troubleshooting. The fact that logs are the only information an administrator may have for an incident, makes logging system a crucial part of an IT infrastructure. In large scale infrastructures, such as LHCb Online, where quite a few GB of logs are produced daily, it is impossible for a human to review all of these logs. Moreover, a great percentage of them as just n oise . That makes clear that a more automated and sophisticated approach is needed. In this paper, we present a low-cost centralized logging system which allow us to do in-depth analysis of every log.

  2. A neutron well logging system

    International Nuclear Information System (INIS)

    1980-01-01

    A pulsed neutron well logging system using a sealed off neutron generator tube is provided with a programmable digital neutron output control system. The control system monitors the target beam current and compares a function of this current with a pre-programmed control function to develop a control signal for the neutron generator. The control signal is used in a series regulator to control the average replenisher current of the neutron generator tube. The programmable digital control system of the invention also provides digital control signals as a function of time to provide ion source voltages. This arrangement may be utilized to control neutron pulses durations and repetition rates or to produce other modulated wave forms for intensity modulating the output of the neutron generator as a function of time. (Auth.)

  3. Decomposable log-linear models

    DEFF Research Database (Denmark)

    Eriksen, Poul Svante

    can be characterized by a structured set of conditional independencies between some variables given some other variables. We term the new model class decomposable log-linear models, which is illustrated to be a much richer class than decomposable graphical models.It covers a wide range of non...... The present paper considers discrete probability models with exact computational properties. In relation to contingency tables this means closed form expressions of the maksimum likelihood estimate and its distribution. The model class includes what is known as decomposable graphicalmodels, which......-hierarchical models, models with structural zeroes, models described by quasi independence and models for level merging. Also, they have a very natural interpretation as they may be formulated by a structured set of conditional independencies between two events given some other event. In relation to contingency...

  4. Well logging, atom and geology

    International Nuclear Information System (INIS)

    Serra, O.

    1994-01-01

    Well logging techniques exploit interactions of gamma photons and neutrons with atoms. Interactions of neutrons of different energies with atoms allow the detection and evaluation of the weight percentage of several elements composing the rocks (C, O, Si, Ca, Fe, S); spectrometry of gamma rays produced by thermal neutron absorption allows for the weight percentage determination of Si, Ca, Fe, S, Cl, H, Ti and Gd, etc. High resolution detectors (germanium doped by Li, at liquid nitrogen temperature) allow the recognition of more elements. Other techniques involving neutrons consist in determining the population in epithermal neutrons at a certain distance of the neutron source (measurement of the hydrogen index). By analyzing the intensity of the gamma flux produced by Compton scattering, the electronic and bulk densities of the rocks are measured. All these data lead to the detection and evaluation of ore deposits (uranium and potassium) and coal, and determination of the lithology, the main minerals composing the rocks, petrophysical properties... 1 fig

  5. Stratigraphic variation of complex impurities in platform limestones and possible significance of atmospheric dust: a study with emphasis on gamma-ray spectrometry and magnetic susceptibility outcrop logging (Eifelian-Frasnian, Moravia, Czech Republic)

    Science.gov (United States)

    Hladil, J.; Gersl, M.; Strnad, L.; Frana, J.; Langrova, A.; Spisiak, J.

    2006-07-01

    Mineral dust and other constituents of Devonian atmospheric aerosols together with certain amounts of aquatic suspensions of riverine detrital origin, colloidal particle dispersions and seawater solutes were embedded in ~95-98% (or purer) limestones on a consistently subsiding isolated carbonate platform where they formed very complex impurity systems. Very low Th/U values, relative abundance of Fe but a slight excess of K typically characterize these ultrafine impurities which are mineralogically dominated by smectite-illite and mica (sericite) together with goethite. In vertical section, these impurities are arranged like incremental series of light and dense bands. The combined method of natural gamma-ray spectrometric and magnetic susceptibility measurements (GRS-MS) together with background of major and trace element analyses provided first systematic insights into fine-scale variability of these impurities in a pile of pure carbonate platform beds, mostly in inner platform Amphipora limestone facies. These carbonates were deposited close to sea level but far from river mouths, and they represented a certain sort of a relatively “independent” medium that was primarily sensitive to climatically (and by rare events) controlled input of atmospheric dust. A remarkable similarity of MS stratigraphic patterns that reflect the quantity and quality of embedded impurities in very distant and paleogeographically separated Devonian basins might be seen as supporting this viewpoint. A long composite stratigraphic section of the Moravian Karst ranges from mid-Eifelian to end-Frasnian levels and yields a number of time characterizing GRS-MS variations that can potentially serve as templates for high-resolution stratigraphic correlations over long distances.

  6. PULSAR: an inductive pulse power source

    International Nuclear Information System (INIS)

    Cnare, E.C.; Brooks, W.P.; Cowan, M.

    1979-01-01

    The PULSAR concept of inductive pulsed power source uses a flux-compressing metallic or plasma armature rather than a fast opening switch to transfer magnetic flux to a load. The inductive store may be a relatively unsophisticated dc superconducting magnet since no magnetic energy is taken from it, and no large current transients are induced in it. Initial experimental efforts employed either expendable or reusable metallic armatures with a 200 kJ, 450 mm diameter superconducting magnet. Attention is now being focused on the development of much faster plasma armatures for use in larger systems of one and two meters diameter. Techniques used to generate the required high magnetic Reynolds number flow will be described and initial experimental results will be presented

  7. Diagnostics of internal inductance in HT-7

    International Nuclear Information System (INIS)

    Zeng Li; Wan Baonian; Qian Jinping; Fan Hengyu

    2001-01-01

    Two arrays of Mirnov coils and a pair of concentric loops have been installed to superconducting tokamak HT-7. Software compensation and digital Fourier series expansion are the two techniques that have been applied successfully in measuring diamagnetic flux of concentric loops and internal inductance. The internal inductance of plasma l i , poloidal beta β p , Grad Shafranov parameter Λ, plasma minor radius α p and the center of the outermost magnetic flux surface Δ g are determined

  8. Geomicrobial Optical Logging Detectors (GOLD)

    Science.gov (United States)

    Bramall, N. E.; Stoker, C. R.; Price, P. B.; Coates, J. D.; Allamandola, L. J.; Mattioda, A. L.

    2008-12-01

    We will present concepts for downhole instrumentation that could be used in the Deep Underground Science and Engineering Laboratory (DUSEL). We envision optical borehole-logging instruments that could monitor bacterial concentration, mineralogy, aromatic organics, temperature and oxygen concentration, allowing for the in situ monitoring of time-dependent microbial and short-scale geologic processes and provide valuable in situ data on stratigraphy to supplement core analyses, especially where instances of missing or damaged core sections make such studies difficult. Incorporated into these instruments will be a sampling/inoculation tool to allow for the recovery and/or manipulation of particularly interesting sections of the borehole wall for further study, enabling a series of microbiological studies. The borehole tools we will develop revolve around key emerging technologies and methods, some of which are briefly described below: 1) Autofluorescence Spectroscopy: Building on past instruments, we will develop a new borehole logger that searches for microbial life and organics using fluorescence spectroscopy. Many important organic compounds (e.g. PAHs) and biomolecules (e.g. aromatic amino acids, proteins, methanogenic coenzymes) fluoresce when excited with ultraviolet and visible light. Through the careful selection of excitation wavelength(s) and temporal gating parameters, a borehole logging instrument can detect and differentiate between these different compounds and the mineral matrix in which they exist. 2) Raman Spectroscopy: Though less sensitive than fluorescence spectroscopy, Raman spectroscopy is more definitive: it can provide important mineral phase distribution/proportions and other chemical data enabling studies of mineralogy and microbe-mineral interactions (when combined with fluorescence). 3) Borehole Camera: Imaging of the borehole wall with extended information in the UV, visible, and NIR for a more informative view can provide a lot of insight

  9. Induction accelerator test module for HIF

    International Nuclear Information System (INIS)

    Faltens, A.

    1991-04-01

    An induction linac test module suitable for investigating the drive requirements and the longitudinal coupling impedance of a high-power ion induction linac has been constructed by the Heavy Ion Fusion (HIF) group at LBL. The induction linac heavy ion driver for inertial confinement fusion (ICF) as presently envisioned uses multiple parallel beams which are transported in separate focusing channels but accelerated together in the induction modules. The resulting induction modules consequently have large beam apertures-1--2 meters in diameter- and correspondingly large outside diameters. The module geometry is related to a low-frequency ''gap capacity'' and high-frequency structural resonances, which are affected by the magnetic core loading and the module pulser impedance. A description of the test module and preliminary results are presented. 3 figs

  10. California-Nevada uranium logging. Final report

    International Nuclear Information System (INIS)

    1981-04-01

    The purpose of this project was to obtain geophysical logs of industry drill holes to assess the uranium resource potential of geologic formations of interest. The work was part of the US Department of Energy's National Uranium Resource Evaluation (NURE) Program. The principal objective of the logging program was to determine radioelement grade of formations through natural gamma ray detectors. Supplementary information was obtained from resistivity (R), self-potential (SP), point resistance (RE), and neutron density (NN) logs for formation interpretation. Additional data for log interpretation was obtained from caliper logs, casing schedules, and downhole temperature. This data was obtained from well operators when available, with new logs obtained where not formerly available. This report contains a summary of the project and data obtained to date

  11. Pembangkitan Data dari Distribusi Log-logistik

    Directory of Open Access Journals (Sweden)

    Aceng Komarudin Mutaqin

    2014-11-01

    Full Text Available Distribusi log-logistik merupakan salah satu distribusi yang dapat diaplikasikan untuk data mutu lingkungan. Makalah ini membahas pembangkitan data dari distribusi log-logistik mulai dari pembangunan algoritme sampai pembuatan program komputer pada perangkat lunak MATLAB. Metode pembangkitan datanya menggunakan metode inverse transform. Ada dua jenis data yang dibangkitkan, yaitu data lengkap dan data tersensor kiri. Dalam makalah ini diberikan contoh data yang dibangkitkan dari distribusi log-logistik.

  12. SNG-logs at the Bagsvaerd Lake

    International Nuclear Information System (INIS)

    Korsbech, U.

    1992-11-01

    Spectral Natural Gamma-logs (SNG) were taken in old boreholes around Bagsvaerd Lake (Zealand). The purpose of this investigation was to clarify the geologic/lithologic conditions in this region and the potential risks of waste penetration into ground water. Relationship curves for thorium, uranium and potassium concentrations are given. Some special logs which can be useful for evaluating concentration variations or transition forms among various lithological layers are collected. Appendices contain technical information on the boreholes and discussion of differences between results of SNG-logging and the conventional gamma-logging. (EG)

  13. 32 CFR 700.846 - Status of logs.

    Science.gov (United States)

    2010-07-01

    ... Officers Afloat § 700.846 Status of logs. The deck log, the engineering log, the compass record, the bearing hooks, the engineer's bell book, and any records generated by automated data logging equipment...

  14. Benefits of obtaining log data in horizontal wells in the WCSB

    Energy Technology Data Exchange (ETDEWEB)

    Spratt, D. [Reeves Wireline Technologies Ltd., Calgary, AB (Canada)

    2001-11-01

    A Compact Memory Logging (CML) system developed by Reeves Wireline Technologies was presented. It can be used to obtain log data from horizontal wells to get a better understanding of how to enhance production or completion techniques. The methods that are commonly used to obtain data from horizontal wells include measurement while drilling (MWD), logging while drilling (LWD), wet connect pipe conveyed wireline logging and CML. Each method has its unique benefits that range from information on lithology, rock parameters and fluid interfaces. Reeves has been using wireless pipe conveyed CML over the past two years. The log data includes array induction, dual spaced neutron and photo density porosity, Pe, gamma ray, compensated sonic and hose size caliper. Reeves CML is smaller, easily conveyed and has an unprecedented capability to bend and is considered to be well suited for both newly and previously drilled horizontal wells that require remedial assessment. The tool can be used to determine reservoir quality and boundaries, establish zone structures, or identify fluid interfaces for strategic planning of completions and stimulations. This paper presented examples of logs on some horizontal wells that indicate the value of obtaining log data. Reeves CML is considered to be economically and operationally ideal, particularly since data from the CML includes depth of investigation. 5 figs.

  15. Velocity measurement of conductor using electromagnetic induction

    International Nuclear Information System (INIS)

    Kim, Gu Hwa; Kim, Ho Young; Park, Joon Po; Jeong, Hee Tae; Lee, Eui Wan

    2002-01-01

    A basic technology was investigated to measure the speed of conductor by non-contact electromagnetic method. The principle of the velocity sensor was electromagnetic induction. To design electromagnet for velocity sensor, 2D electromagnetic analysis was performed using FEM software. The sensor output was analyzed according to the parameters of velocity sensor, such as the type of magnetizing currents and the lift-off. Output of magnetic sensor was linearly depended on the conductor speed and magnetizing current. To compensate the lift-off changes during measurement of velocity, the other magnetic sensor was put at the pole of electromagnet.

  16. FLOZ-the computer program for the primary interpretation of nuclear borehole logging

    International Nuclear Information System (INIS)

    Zorski, T.

    1979-01-01

    This work presents the FLOZ program for nuclear well logging data interpretation. Program has been written in FORTRAN 1900 language for ODRA 1300 computers. The description of the program possibilities and the ways of its application are given. Short presentation of the interpretation method used here and the description of the program work with its complete listing, together with the explanatory commentaries are also presented. The type of interpretation performed by the program depends upon the kind of nuclear logging of interest. For neutron-gamma and gamma-gamma logging the program introduces the corrections for the following disturbing factors: the ratemeter time constant, the logging speed, the apparatus dead time, the gamma-ray background. The gamma-ray logging is corrected for the following disturbing factors: ratemeter time constant, the logging speed, the apparatus dead time of tool, borehole radius, gamma-ray absorbtion in the borehole liquid and the finite thickness of the layers. The calibration constant for gamma-ray probe can be introduced for calculations of radioactivity ore grades. The log deflections being the input data for the FLOZ program, are taken from specially prepared magnetic tape. The results of interpretation are written on magnetic tape, according to the X3GY system for the ODRA 1300 computers. The method of interpretation which is applicated in program FLOZ was elaborated by Prof. J.A. Czubek from Institute of Nuclear Physics in Cracow. (author)

  17. A Magnetized Nanoparticle Based Solid-Phase Extraction Procedure Followed by Inductively Coupled Plasma Atomic Emission Spectrometry to Determine Arsenic, Lead and Cadmium in Water, Milk, Indian Rice and Red Tea.

    Science.gov (United States)

    Azimi, Salameh; Es'haghi, Zarrin

    2017-06-01

    A sensitive and simple method using magnetic multi-walled carbon nanotube (MWCNTs-Fe 3 O 4 MNP), as the adsorbent, has been successfully developed for extraction and pre-concentration of arsenic, lead and cadmium with detection by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). The nanosorbent was characterized by Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction pattern (XRD), vibrating sample magnetometer (VSM) and transmission electron microscopy (TEM). The key factors affecting the signal intensity such as pH, adsorbent amount, etc. were investigated. Under optimal conditions, the limits of detection (three-time of signal to noise ratio, S/N 3) were 0.3, 0.6, 0.3 ng/mL for arsenic, lead and cadmium, respectively. Application of the adsorbent was investigated by the analysis of water, milk, Indian rice and red tea. The experimental data was analyzed and obeyed Langmuir and Freundlich adsorption models. The kinetic data was fitted to the pseudo-second-order model. Thermodynamic studies revealed the feasibility and exothermic nature of the system.

  18. Influence of borehole-eccentred tools on wireline and logging-while-drilling sonic logging measurements

    KAUST Repository

    Pardo, David; Matuszyk, Paweł Jerzy; Torres-Verdí n, Carlos; Mora Cordova, Angel; Muga, Ignacio; Calo, Victor M.

    2013-01-01

    We describe a numerical study to quantify the influence of tool-eccentricity on wireline (WL) and logging-while-drilling (LWD) sonic logging measurements. Simulations are performed with a height-polynomial-adaptive (hp) Fourier finite-element method

  19. Log canonical thresholds of smooth Fano threefolds

    International Nuclear Information System (INIS)

    Cheltsov, Ivan A; Shramov, Konstantin A

    2008-01-01

    The complex singularity exponent is a local invariant of a holomorphic function determined by the integrability of fractional powers of the function. The log canonical thresholds of effective Q-divisors on normal algebraic varieties are algebraic counterparts of complex singularity exponents. For a Fano variety, these invariants have global analogues. In the former case, it is the so-called α-invariant of Tian; in the latter case, it is the global log canonical threshold of the Fano variety, which is the infimum of log canonical thresholds of all effective Q-divisors numerically equivalent to the anticanonical divisor. An appendix to this paper contains a proof that the global log canonical threshold of a smooth Fano variety coincides with its α-invariant of Tian. The purpose of the paper is to compute the global log canonical thresholds of smooth Fano threefolds (altogether, there are 105 deformation families of such threefolds). The global log canonical thresholds are computed for every smooth threefold in 64 deformation families, and the global log canonical thresholds are computed for a general threefold in 20 deformation families. Some bounds for the global log canonical thresholds are computed for 14 deformation families. Appendix A is due to J.-P. Demailly.

  20. Aggregation of log-linear risks

    DEFF Research Database (Denmark)

    Embrechts, Paul; Hashorva, Enkeleijd; Mikosch, Thomas Valentin

    2014-01-01

    In this paper we work in the framework of a k-dimensional vector of log-linear risks. Under weak conditions on the marginal tails and the dependence structure of a vector of positive risks, we derive the asymptotic tail behaviour of the aggregated risk {and present} an application concerning log...

  1. Synthetic rope applications in Appalachian logging

    Science.gov (United States)

    Ben D. Spong; Jingxin Wang

    2008-01-01

    New ultra-high molecular weight polyethylene rope has shown good results as a replacement for wire rope in logging applications in the western United States. A single case study trial was performed in Appalachian forest conditions to assess the appropriateness of this technology for hardwood logging applications. The study focused on use of the rope in West Virginia...

  2. Palm distributions for log Gaussian Cox processes

    DEFF Research Database (Denmark)

    Coeurjolly, Jean-Francois; Møller, Jesper; Waagepetersen, Rasmus

    This paper reviews useful results related to Palm distributions of spatial point processes and provides a new result regarding the characterization of Palm distributions for the class of log Gaussian Cox processes. This result is used to study functional summary statistics for a log Gaussian Cox...

  3. Log-binomial models: exploring failed convergence.

    Science.gov (United States)

    Williamson, Tyler; Eliasziw, Misha; Fick, Gordon Hilton

    2013-12-13

    Relative risk is a summary metric that is commonly used in epidemiological investigations. Increasingly, epidemiologists are using log-binomial models to study the impact of a set of predictor variables on a single binary outcome, as they naturally offer relative risks. However, standard statistical software may report failed convergence when attempting to fit log-binomial models in certain settings. The methods that have been proposed in the literature for dealing with failed convergence use approximate solutions to avoid the issue. This research looks directly at the log-likelihood function for the simplest log-binomial model where failed convergence has been observed, a model with a single linear predictor with three levels. The possible causes of failed convergence are explored and potential solutions are presented for some cases. Among the principal causes is a failure of the fitting algorithm to converge despite the log-likelihood function having a single finite maximum. Despite these limitations, log-binomial models are a viable option for epidemiologists wishing to describe the relationship between a set of predictors and a binary outcome where relative risk is the desired summary measure. Epidemiologists are encouraged to continue to use log-binomial models and advocate for improvements to the fitting algorithms to promote the widespread use of log-binomial models.

  4. LHCb Online Log Analysis and Maintenance System

    CERN Document Server

    Garnier, J-C

    2011-01-01

    History has shown, many times computer logs are the only information an administrator may have for an incident, which could be caused either by a malfunction or an attack. Due to the huge amount of logs that are produced from large-scale IT infrastructures, such as LHCb Online, critical information may be overlooked or simply be drowned in a sea of other messages. This clearly demonstrates the need for an automatic system for long-term maintenance and real time analysis of the logs. We have constructed a low cost, fault tolerant centralized logging system which is able to do in-depth analysis and cross-correlation of every log. This system is capable of handling O(10000) different log sources and numerous formats, while trying to keep the overhead as low as possible. It provides log gathering and management, Offline analysis and online analysis. We call Offline analysis the procedure of analyzing old logs for critical information, while Online analysis refer to the procedure of early alerting and reacting. ...

  5. A semantic perspective on query log analysis

    NARCIS (Netherlands)

    Hofmann, K.; de Rijke, M.; Huurnink, B.; Meij, E.

    2009-01-01

    We present our views on the CLEF log file analysis task. We argue for a task definition that focuses on the semantic enrichment of query logs. In addition, we discuss how additional information about the context in which queries are being made could further our understanding of users’ information

  6. Utilization and cost for animal logging operations

    Science.gov (United States)

    Suraj P. Shrestha; Bobby L. Lanford

    2001-01-01

    Forest harvesting with animals is a labor-intensive operation. Due to the development of efficient machines and high volume demands from the forest products industry, mechanization of logging developed very fast, leaving behind the traditional horse and mule logging. It is expensive to use machines on smaller woodlots, which require frequent moves if mechanically...

  7. Impacts of extended working hours in logging

    Science.gov (United States)

    Dana Mitchell; Tom Gallagher

    2008-01-01

    Last year at the 2007 AIM in Minneapolis, MN, the authors presented the human factors impacts to consider when implementing extended working hours in the logging industry. In a continuation of this project, we have researched existing literature to identify possible actions that logging business owners can take to reduce the impact of extended working hours on their...

  8. Neutron logging reliability techniques and apparatus

    International Nuclear Information System (INIS)

    Johnstone, C.W.

    1978-01-01

    This invention relates in general to neutron logging of earth formations, and in particular, to novel apparatus and procedures for determining the validity, or reliability, of data derived at least in part by logging neutron characteristics of earth formations and, if desired, for affording verifiably accurate indications of such data

  9. Neutron logging reliability techniques and apparatus

    International Nuclear Information System (INIS)

    Johnstone, C.W.

    1974-01-01

    This invention relates in general to neutron logging of earth formations, and in particular, to novel apparatus and procedures for determining the validity, or reliability, of data derived at least in part by logging neutron characteristics of earth formations and, if desired, for affording verifiably accurate indications of such data. (author)

  10. Logging methods and peeling of Aspen

    Science.gov (United States)

    T. Schantz-Hansen

    1948-01-01

    The logging of forest products is influenced by many factors, including the size of the trees, density of the stand, the soundness of the trees, size of the area logged, topography and soil, weather conditions, the degree of utilization, the skill of the logger and the equipment used, the distance from market, etc. Each of these factors influences not only the method...

  11. Log Analysis Using Splunk Hadoop Connect

    Science.gov (United States)

    2017-06-01

    23 A. INPUT SELECTION ...Conversion Resource Consumption .............................................. 28 Figure 8. Distribution of Events in Years...running a logging service puts a performance tax on the system and may cause the degradation of performance. More thorough 8 logging will cause a

  12. Grading sugar pine saw logs in trees.

    Science.gov (United States)

    John W. Henley

    1972-01-01

    Small limbs and small overgrown limbs cause problems when grading saw logs in sugar pine trees. Surface characteristics and lumber recovery information for 426 logs from 64 sugar pine trees were examined. Resulting modifications in the grading specification that allow a grader to ignore small limbs and small limb indicators do not appear to decrease the performance of...

  13. Analysis of RIA standard curve by log-logistic and cubic log-logit models

    International Nuclear Information System (INIS)

    Yamada, Hideo; Kuroda, Akira; Yatabe, Tami; Inaba, Taeko; Chiba, Kazuo

    1981-01-01

    In order to improve goodness-of-fit in RIA standard analysis, programs for computing log-logistic and cubic log-logit were written in BASIC using personal computer P-6060 (Olivetti). Iterative least square method of Taylor series was applied for non-linear estimation of logistic and log-logistic. Hear ''log-logistic'' represents Y = (a - d)/(1 + (log(X)/c)sup(b)) + d As weights either 1, 1/var(Y) or 1/σ 2 were used in logistic or log-logistic and either Y 2 (1 - Y) 2 , Y 2 (1 - Y) 2 /var(Y), or Y 2 (1 - Y) 2 /σ 2 were used in quadratic or cubic log-logit. The term var(Y) represents squares of pure error and σ 2 represents estimated variance calculated using a following equation log(σ 2 + 1) = log(A) + J log(y). As indicators for goodness-of-fit, MSL/S sub(e)sup(2), CMD% and WRV (see text) were used. Better regression was obtained in case of alpha-fetoprotein by log-logistic than by logistic. Cortisol standard curve was much better fitted with cubic log-logit than quadratic log-logit. Predicted precision of AFP standard curve was below 5% in log-logistic in stead of 8% in logistic analysis. Predicted precision obtained using cubic log-logit was about five times lower than that with quadratic log-logit. Importance of selecting good models in RIA data processing was stressed in conjunction with intrinsic precision of radioimmunoassay system indicated by predicted precision. (author)

  14. Model wells for nuclear well logging

    International Nuclear Information System (INIS)

    Tittle, C.W.

    1989-01-01

    Considerations needed in the design and construction of model wells for nuclear log calibration are covered, with special attention to neutron porosity logging and total γ-ray logging. Pulsed neutron decay-time and spectral γ-ray logging are discussed briefly. The American Petroleum Institute calibration facility for nuclear logs is a good starting point for similar or expanded facilities. A few of its shortcomings are mentioned; they are minor. The problem of fluid saturation is emphasized. Attention is given to models made of consolidated rock and those containing unconsolidated material such as Ottawa sand. Needed precautions are listed. A similarity method is presented for estimating the porosity index of formations that are not fully saturated. (author)

  15. Processing of gamma-ray spectrometric logs

    International Nuclear Information System (INIS)

    Umiastowski, K.; Dumesnil, P.

    1984-10-01

    CEA (Commissariat a l'Energie Atomique) has developped a gamma-ray spectrometric tool, containing an analog-to-digital converter. This new tool permits to perform very precise uranium logs (natural gamma-ray spectrometry), neutron activation logs and litho-density logs (gamma-gamma spectrometric logs). Specific processing methods were developped to treate the particular problems of down-hole gamma-ray spectrometry. Extraction of the characteristic gamma-ray peak, even if they are superposed on the background radiation of very high intensity, is possible. This processing methode enables also to obtain geological informations contained in the continuous background of the spectrum. Computer programs are written in high level language for SIRIUS (VICTOR) and APOLLO computers. Exemples of uranium and neutron activation logs treatment are presented [fr

  16. Induction Motors by Electric Measurements

    Directory of Open Access Journals (Sweden)

    Andrzej M. Trzynadlowski

    1999-01-01

    Full Text Available The paper gives an overview of the issues and means of detection of mechanical abnormalities in induction motors by electric measurements. If undetected and untreated, the worn or damaged bearings, rotor imbalance and eccentricity, broken bars of the rotor cage, and torsional and lateral vibration lead to roughly a half of all failures of induction motor drives. The detection of abnormalities is based on the fact that they cause periodic disturbance of motor variables, such as the speed, torque, current, and magnetic flux. Thus, spectral analysis of those or related quantities may yield a warning about an incipient failure of the drive system. Although the traditional non-invasive diagnostics has mostly been based on the signature analysis of the stator current, other media can also be employed. In particular, the partial instantaneous input power is shown, theoretically and experimentally, to offer distinct advantages under noisy operating conditions. Use of torque and flux estimates is also discussed.

  17. LOG2MARKUP: State module to transform a Stata text log into a markup document

    DEFF Research Database (Denmark)

    2016-01-01

    log2markup extract parts of the text version from the Stata log command and transform the logfile into a markup based document with the same name, but with extension markup (or otherwise specified in option extension) instead of log. The author usually uses markdown for writing documents. However...

  18. Processing well logging data, for example for verification and calibration of well logs

    International Nuclear Information System (INIS)

    Suau, J.; Boutemy, Y.

    1981-01-01

    A method is described of machine processing well logging data derived from borehole exploring devices which investigate earth formations traversed by boreholes. The method can be used for verifying and recalibrating logs, reconstructing missing logs and combining the data to form a statistical model of the traversed earth formations. (U.K.)

  19. Inductive Monitoring System (IMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...

  20. Inductive Reasoning and Writing

    Science.gov (United States)

    Rooks, Clay; Boyd, Robert

    2003-01-01

    Induction, properly understood, is not merely a game, nor is it a gimmick, nor is it an artificial way of explaining an element of reasoning. Proper understanding of inductive reasoning--and the various types of reasoning that the authors term inductive--enables the student to evaluate critically other people's writing and enhances the composition…

  1. Digitization, correction, and standardization of geophysical logs from deep boreholes of Central New York State. Final technical report

    International Nuclear Information System (INIS)

    Robinson, J.E.

    1981-07-01

    Digitization and standardization of suitable logs are provided from wells located in the area of Central New York that had been under consideration as a possible site for the disposal of radioactive waste. Digitized logs included those with geophysical parameters that could be analyzed for formation porosity and lithology and in which the log interval was sufficient to evaluate formation parameters. Digitizing equipment was purchased, interfaced, and necessary software was written and documented. Magnetic tapes and hard copy playbacks of all digitized well logs are being forwarded to the Department of Energy repository at Battelle Memorial Institute for use in future projects

  2. Analysis of geophysical well logs from the Mariano Lake-Lake Valley drilling project, San Juan Basin, Northwestern New Mexico

    International Nuclear Information System (INIS)

    Scott, J.H.

    1986-01-01

    Geophysical well logs were obtained in eight deep holes drilled and cored by the U.S. Geological Survey to examine the geology of the Mariano Lake-Lake Valley area in the southern part of the San Juan basin, New Mexico. The logs were made to determine the petrophysical properties of the rocks penetrated by the holes, to aid in making stratigraphic correlations between the holes, and to estimate the grade of uranium enrichment in mineralized zones. The logs can be divided into six categories-nuclear, electric, sonic, magnetic, dipmeter, and borehole conditions. Examples of these logs are presented and related to lithological and petrophysical properties of the cores recovered. Gamma-ray and prompt fission neutron logs were used to estimate uranium grade in mineralized zones. Resistivity and spontaneous potential logs were used to make stratigraphic correlations between drill holes and to determine the variability of the sandstone:mudstone ratios of the major sedimentary units. In one drill hole a dipmeter log was used to estimate the direction of sediment transport of the fluvial host rock. Magnetic susceptibility logs provided supportive information for a laboratory study of magnetic mineral alteration in drill cores. This study was used to infer the geochemical and hydrologic environment associated with uranium deposition in the project area

  3. Nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    In a method of imaging a body in which nuclear magnetic resonance is excited in a region including part of the body, and the free induction decay signal is measured, a known quantity of a material of known nuclear magnetic resonance properties, for example a bag of water, is included in the region so as to enhance the measured free induction decay signal. This then reduces the generation of noise during subsequent processing of the signal. (author)

  4. Numerical simulation of induction heating thick-walled tubes

    Directory of Open Access Journals (Sweden)

    Lenhard Richard

    2018-01-01

    Full Text Available In the paper is shown the connection of two toolboxes in an Ansys Workbench solution for induction heating. In Ansys Workbench, Maxwell electromagnetism programs and Fluent have been linked. In Maxwell, a simulation of electromagnetic induction was performed, where data on the magnetic field distribution in the heated material was obtained and then transformed into the Fluent program in which the induction heating simulation was performed.

  5. Energy Optimal Control of Induction Motor Drives

    DEFF Research Database (Denmark)

    Abrahamsen, Flemming

    This thesis deals with energy optimal control of small and medium-size variable speed induction motor drives for especially Heating, Ventilation and Air-Condition (HVAC) applications. Optimized efficiency is achieved by adapting the magnetization level in the motor to the load, and the basic...... demonstrated that energy optimal control will sometimes improve and sometimes deteriorate the stability. Comparison of small and medium-size induction motor drives with permanent magnet motor drives indicated why, and in which applications, PM motors are especially good. Calculations of economical aspects...... improvement by energy optimal control for any standard induction motor drive between 2.2 kW and 90 kW. A simple method to evaluate the robustness against load disturbances was developed and used to compare the robustness of different motor types and sizes. Calculation of the oscillatory behavior of a motor...

  6. Induction machine handbook

    CERN Document Server

    Boldea, Ion

    2002-01-01

    Often called the workhorse of industry, the advent of power electronics and advances in digital control are transforming the induction motor into the racehorse of industrial motion control. Now, the classic texts on induction machines are nearly three decades old, while more recent books on electric motors lack the necessary depth and detail on induction machines.The Induction Machine Handbook fills industry's long-standing need for a comprehensive treatise embracing the many intricate facets of induction machine analysis and design. Moving gradually from simple to complex and from standard to

  7. Logística del transporte

    OpenAIRE

    Robusté Antón, Francesc

    2005-01-01

    La logística se ha conformado como un proceso estratégico para organizar las actividades de producción y de distribución de las empresas. El concepto de sistema logístico ha incluido un amplio espectro de operaciones que condicionan la eficiencia y la competitividad empresarial en el actual contexto de globalización de la economía. En este sentido, este libro afronta y analiza los distintos aspectos que inciden en los procesos de planificación y gestión de los procesos logísticos relacionados...

  8. Nonblocking and orphan free message logging protocols

    Science.gov (United States)

    Alvisi, Lorenzo; Hoppe, Bruce; Marzullo, Keith

    1992-12-01

    Currently existing message logging protocols demonstrate a classic pessimistic vs. optimistic tradeoff. We show that the optimistic-pessimistic tradeoff is not inherent to the problem of message logging. We construct a message-logging protocol that has the positive features of both optimistic and pessimistic protocol: our protocol prevents orphans and allows simple failure recovery; however, it requires no blocking in failure-free runs. Furthermore, this protocol does not introduce any additional message overhead as compared to one implemented for a system in which messages may be lost but processes do not crash.

  9. Supply of Rubber Wood Log in Malaysia

    OpenAIRE

    Noraida, A. W.; Abdul-Rahim, A. S.

    2014-01-01

    Issue on shortage of raw material for wood processing solved by discovery of rubber wood log as one of the substitutes the natural log. This paper examines the supply of rubber wood log in Malaysia. We employ ARDL Bound Approach Test and time series data from 1980 to 2010 which represented the whole Malaysia are used to achieve the established objectives. The result shown, in the long run harvested area and wages have 1% and 10% significant level respectively. While in the short run, there wa...

  10. Study of linear induction motor characteristics : the Mosebach model

    Science.gov (United States)

    1976-05-31

    This report covers the Mosebach theory of the double-sided linear induction motor, starting with the ideallized model and accompanying assumptions, and ending with relations for thrust, airgap power, and motor efficiency. Solutions of the magnetic in...

  11. Coreless Concept for High Gradient Induction Cell

    International Nuclear Information System (INIS)

    Krasnykh, Anatoly

    2008-01-01

    An induction linac cell for a high gradient is discussed. The proposed solid state coreless approach for the induction linac topology (SLIM(reg s ign)) is based on nanosecond mode operation. This mode may have an acceleration gradient comparable with gradients of rf- accelerator structures. The discussed induction system has the high electric efficiency. The key elements are a solid state semiconductor switch and a high electric density dielectric with a thin section length. The energy in the induction system is storied in the magnetic field. The nanosecond current break-up produces the high voltage. The induced voltage is used for acceleration. This manner of an operation allows the use of low voltage elements in the booster part and achieves a high accelerating gradient. The proposed topology was tested in POP (proof of principle) experiments

  12. Induction generator-induction motor wind-powered pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, M.S.; Lyra, R.O.C.; Silva, S.R. [CPDEE - UFMG, Belo Horizonte (Brazil)

    1997-12-31

    The energy storage matter plays an important role in wind-electric conversion systems for isolated applications. Having that in mind, two different approaches can be basically considered: either the immediate conversion of the generated electric energy, as in a water pumping system or electric energy storage for later use, as in a battery charging system. Due to some features such as no need of an external reactive power source and, sometimes, a gearbox, permanent-magnet synchronous generators have been broadly used in low rated power isolated systems. Despite that, system performance can be affected when the generator is feeding an inductive load (e.g., an induction motor) under variable-speed-variable-frequency operational conditions. Since there is no effective flux control, motor overload may occur at high wind speeds. Thus, good system performance can be obtained through additional control devices which may increase system cost. Although being rugged and cheap, induction machines always work as a reactive power drain; therefore, they demand an external reactive power source. Considering that, reactive static compensators appear as an attractive alternative to the cost x performance problem. In addition to that, different control strategies can be used so that system performance can be improved.

  13. Value of NMR logging for heavy oil characterization

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S.; Chen, J.; Georgi, D. [Baker Hughes, Calgary, AB (Canada); Sun, B. [Chevron Energy Technology Co., Calgary, AB (Canada)

    2008-07-01

    Non-conventional, heavy oil fields are becoming increasingly important to the security of energy supplies and are becoming economically profitable to produce. Heavy oil reservoirs are difficult to evaluate since they are typically shallow and the connate waters are very fresh. Other heavy oil reservoirs are oil-wet where the resistivities are not indicative of saturation. Nuclear magnetic resonance (NMR) detects molecular level interactions. As such, it responds distinctively to different hydrocarbon molecules, thereby opening a new avenue for constituent analysis. This feature makes NMR a more powerful technique than bulk oil density or viscosity measurements for characterizing oils, and is the basis for detecting gas in heavy oil fields. NMR logging, which measures fluid in pore space directly, is capable of separating oil from water. It is possible to discern movable from bound water by analyzing NMR logs. The oil viscosity can be also quantified from NMR logs, NMR relaxation time and diffusivity estimates. The unique challenges for heavy oil reservoir characterization for the NMR technique were discussed with reference to the extra-fast decay of the NMR signal in response to extra-heavy oil/tars, and the lack of sensitivity in measuring very slow diffusion of heavy oil molecules. This paper presented various methods for analyzing heavy oil reservoirs in different viscosity ranges. Heavy oil fields in Venezuela, Kazakhstan, Canada, Alaska and the Middle East were analyzed using different data interpretation approaches based on the reservoir formation characteristics and the heavy oil type. NMR direct fluid typing was adequate for clean sands and carbonate reservoirs while integrated approaches were used to interpret extra heavy oils and tars. It was concluded that NMR logs can provide quantitative measures for heavy oil saturation, identify sweet spots or tar streaks, and quantify heavy oil viscosity within reasonable accuracy. 14 refs., 16 figs.

  14. 双馈风电机组与高速永磁风电机组对比分析﹡%Comparison of Doubly-fed Induction Generator and High Speed Permanent Magnet Wind Power Generator

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    is paper compared two main wind turbines. One is doubly-fed induction generator, the other is high speed permanent magnet wind power generator. It calculated the efficiency and annual electric energy production in different IEC wind classes, and compared the cost based on the market value. A er analyzing the reliability, e ciency and power grid adaptability, it came to the conclusion that two types of wind turbines have di erent advantages and meet di erent requirements from customers. erefore, development of two types of wind turbines will be be er adapted to the market competition.%  本文从风电机组角度对两种主流的发电方式,即双馈式发电机组和高速永磁发电机组,进行了对比分析。计算了两种发电方式的效率及在不同风区的年发电量,根据市场价格对各部件进行成本对比。在综合考虑了可靠性、效率、电网适应性等方面后指出,两种方式各有特点,适合客户的不同需求。因此,作为风电机组开发商,同时开发两种机型方能更好地适应市场的竞争。

  15. Drilling and logging in uranium exploration

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    The report reviews drilling and logging practices in exploration of uranium ores and summarizes the papers presented in the panel meeting. Recommendations for further research and development are given

  16. Neutron logging reliability techniques and apparatus

    International Nuclear Information System (INIS)

    Johnstone, C.W.

    1975-01-01

    Apparatus and methods for verifying the validity of data derived at least in part by neutron logging of earth formations, and, where indicated, for affording neutron diffusion-corrected values of such data, are disclosed. (WHK)

  17. Nuclear log interpretation by first principle

    International Nuclear Information System (INIS)

    Oelgaard, P.L.

    1988-07-01

    A weakness connected to the present interpretation of nuclear borehole logs is that the interdependence of the various logs and physical effects of importance for the tools are not always taken into account in a correct way. Therefore a new approach to the interpretation of nuclear borehole logs is considered. It is based on the logs obtained with the natural gamma, the neutron porosity, the gamma density, and the pulsed neutron tools. For each of these tools a model, taking into account the important physical effects, is established. These models are incorporated into a computer programme which from the tool signals calculates, by use of iteration, a consistent set of the corresponding formation properties. In the paper the models developed for the four tools and the interpretation programme are briefly described. An example of the use of the interpretation programme is given and compared with a conventional interpretation. (author)

  18. CMLOG: A common message logging system

    International Nuclear Information System (INIS)

    Chen, J.; Akers, W.; Bickley, M.; Wu, D.; Watson, W. III

    1997-01-01

    The Common Message Logging (CMLOG) system is an object-oriented and distributed system that not only allows applications and systems to log data (messages) of any type into a centralized database but also lets applications view incoming messages in real-time or retrieve stored data from the database according to selection rules. It consists of a concurrent Unix server that handles incoming logging or searching messages, a Motif browser that can view incoming messages in real-time or display stored data in the database, a client daemon that buffers and sends logging messages to the server, and libraries that can be used by applications to send data to or retrieve data from the database via the server. This paper presents the design and implementation of the CMLOG system meanwhile it will also address the issue of integration of CMLOG into existing control systems. CMLOG into existing control systems

  19. LATTE - Log and Time Tracking for Elections

    Data.gov (United States)

    Office of Personnel Management — LATTE - Log and Time Tracking for Elections is a time tracking and voucher preparation system used to schedule employees to cover elections, to document their time...

  20. Well Logging Equipment Updated in China

    Institute of Scientific and Technical Information of China (English)

    Xu Lili

    1996-01-01

    @@ As one of the ten principal disciplines in the petroleum industry, well logging has been developed for about 55years in China and is playing an increasingly important role in the country's oil and gas exploration and development.

  1. Compound induction electric rotating machine

    Energy Technology Data Exchange (ETDEWEB)

    Decesare, D

    1987-07-28

    The present invention generally relates to dynamo-electric machines cabable of operating in a generator mode or in a motor mode and more specifically, to increased efficiency compound interaction AC and/or DC dynamo-electric machines. This patent describes such a machine having a distributed armature winding in a cylindrical rotor wound to form axial and substantially radial winding portions and including permanent and/or electromagnets to couple magnetic flux into the peripheral or circumferential surface of the rotor, and to provide interaction between a magnetic field formed beyond the rotor axial surfaces and the rotor to thereby enhance the total induction of flux into the rotor for improved, more efficient operation. 28 figs.,

  2. Conversation Threads Hidden within Email Server Logs

    Science.gov (United States)

    Palus, Sebastian; Kazienko, Przemysław

    Email server logs contain records of all email Exchange through this server. Often we would like to analyze those emails not separately but in conversation thread, especially when we need to analyze social network extracted from those email logs. Unfortunately each mail is in different record and those record are not tided to each other in any obvious way. In this paper method for discussion threads extraction was proposed together with experiments on two different data sets - Enron and WrUT..

  3. Nuclear borehole logging for oil exploration

    International Nuclear Information System (INIS)

    Oelgaard, P.L.

    1989-01-01

    Reactor physics can be applied to the logging of boreholes for the exploration of oil and gas and the results obtained can be interpreted more correctly by use of reactor physics models, e.g. one-dimensional multi-group diffusion theory adapted for gamma quanta. The standard nuclear logging tools are: natural gamma, gamma density, neutron porosity and the pulsed-neutron tool. The models and interpretation procedures are discussed. 1 fig

  4. Geophysical logging of the Harwell boreholes

    International Nuclear Information System (INIS)

    Brightman, M.A.

    1983-08-01

    A comprehensive geophysical borehole logging survey was carried out on each of three deep boreholes drilled at the Harwell research site. KOALA and PETRA computer programs were used to analyse and interpret the logs to obtain continuous quantitative estimates of the geological and hydrogeological properties of the sequences penetrated at the Harwell site. Quantitative estimates of the mineral composition and porosity of the cores samples were made. (UK)

  5. Defect core detection in radiata pine logs

    International Nuclear Information System (INIS)

    Wallace, G.

    1993-01-01

    Internal defect cores in Pinus radiata logs arise primarily from the practice in New Zealand of pruning trees to increase the amount of clear wood. Realising the benefits of this practice when milling the logs is hampered by the lack of a practical method for detecting the defect cores. This report attempts to establish industry requirements for detections and examine techniques which may be suitable. Some trials of a novel technique are described. (author) 19 refs.; 11 figs

  6. Modeling Precipitation Extremes using Log-Histospline

    Science.gov (United States)

    Huang, W. K.; Nychka, D. W.; Zhang, H.

    2017-12-01

    One of the commonly used approaches to modeling univariate extremes is the peaks-overthreshold (POT) method. The POT method models exceedances over a (sufficiently high/low) threshold as a generalized Pareto distribution (GPD). To apply this method, a threshold has to be chosen and the estimates might be sensitive to the chosen threshold. Here we propose an alternative, the "Log-Histospline", to explore modeling the tail behavior and the remainder of the density in one step using the full range of the data. Log-Histospline applies a smoothing spline model on a finely binned histogram of the log transformed data to estimate its log density. By construction, we are able to preserve the polynomial upper tail behavior, a feature commonly observed in geophysical observations. The Log-Histospline can be extended to the spatial setting by treating the marginal (log) density at each location as spatially indexed functional data, and perform a dimension reduction and spatial smoothing. We illustrate the proposed method by analyzing precipitation data from regional climate model output (North American Regional Climate Change and Assessment Program (NARCCAP)).

  7. La logística integral como ventaja competitiva y sistema logístico

    Directory of Open Access Journals (Sweden)

    Mario Anselmo Martínez gallardo

    2013-07-01

    Full Text Available Esta investigación analiza la logística integral como una ventaja competitiva y el sistema logístico. Es opinión de los autores que la logística integral es esencial para el intercambio de mercancías, toda vez que reduce costos y hace más ágil la actividad comercial. La utilización de esta logística representa una ventaja competitiva con respecto de otras empresas por la optimización del capital y ahorro de tiempo.

  8. Well logging with natural gamma radiation

    International Nuclear Information System (INIS)

    Ellis, D.V.

    1983-01-01

    An invention is described for use in natural gamma radiation well logging in which measurements taken in a borehole are used in the search for valuable underground resources such as oil or gas. The invention comprises deriving a log of natural gamma radiation detected in selected energy windows for a selected borehole depth interval and converting it into a log of the selected subsurface materials, e.g. Th, U, K. This log is corrected for the effects of 1) either a gamma ray emitter in the borehole fluid, e.g. potassium salts and/or 2) a gamma ray attenuator in the borehole fluid, e.g. a strong attenuator such as barite and/or hematite. The Th, U, K log is particularly useful in the exploration of oil and gas resources since the Th, U, K concentrations are a good indication as to the presence, type and volume of shale and clay in the formations surrounding the borehole. (U.K.)

  9. AML (Advanced Mud Logging: First Among Equals

    Directory of Open Access Journals (Sweden)

    T. Loermans

    2017-09-01

    Full Text Available During the past ten years an enormous development in mud logging technology has been made. Traditional mud logging was only qualitative in nature, and mudlogs could not be used for the petrophysical well evaluations which form the basis for all subsequent activities on wells and fields. AML however can provide quantitative information, logs with a reliability, trueness and precision like LWD and WLL. Hence for well evaluation programmes there are now three different logging methods available, each with its own pros and cons on specific aspects: AML, LWD and WLL. The largest improvements have been made in mud gas analysis and elemental analysis of cuttings. Mud gas analysis can yield hydrocarbon fluid composition for some components with a quality like PVT analysis, hence not only revolutionising the sampling programme so far done with only LWD/WLL, but also making it possible to geosteer on fluid properties. Elemental analysis of cuttings, e.g. with XRF, with an ability well beyond the capabilities of the spectroscopy measurements possible earlier with LWD/WLL tools, is opening up improved ways to evaluate formations, especially of course where the traditional methods are falling short of requirements, such as in unconventional reservoirs. An overview and specific examples of these AML logs is given, from which it may be concluded that AML now ought to be considered as “first among its equals”.

  10. The Characterization of the Magnetic Properties of Soft Magnetic Materials

    DEFF Research Database (Denmark)

    Larsen, Raino Michael

    1996-01-01

    The hysteresis curve and magnetic properties such as permeability, saturation induction, residual induction, coercive force and hysteresis losses are presented. The design and construction of equipment making it possible to measure true DC-values as well as AC-properties of toroid rings and cylin......The hysteresis curve and magnetic properties such as permeability, saturation induction, residual induction, coercive force and hysteresis losses are presented. The design and construction of equipment making it possible to measure true DC-values as well as AC-properties of toroid rings...

  11. Pulsed neutron logging - a modern approach to petroleum exploration

    International Nuclear Information System (INIS)

    Navalkar, M.P.

    1978-01-01

    As hydrocarbons have strikingly different properties for neutrons as compared with rocks, neutronic methods are useful to prepare logs of bore holes drilled for petroleum exploration. The earlier neutron logs were based on steady neutron sources, but the superior logs, namely, neutron life time log and neutron induced spectral log are based on pulsed neutron sources. The methods of obtaining these logs, their limitations and the field equipment required are described briefly. As the two logs are complementary, a plea has been made to develop field equipment which can obtain two logs in a single run. (M.G.B.)

  12. Artificial Inductance Concept to Compensate Nonlinear Inductance Effects in the Back EMF-Based Sensorless Control Method for PMSM

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Lei, Xiao; Blaabjerg, Frede

    2013-01-01

    The back EMF-based sensorless control method is very popular for permanent magnet synchronous machines (PMSMs) in the medium- to high-speed operation range due to its simple structure. In this speed range, the accuracy of the estimated position is mainly affected by the inductance, which varies...... at different loading conditions due to saturation effects. In this paper, a new concept of using a constant artificial inductance to replace the actual varying machine inductance for position estimation is introduced. This facilitates greatly the analysis of the influence of inductance variation...

  13. Fracture diagnostics with tube wave reflection logs

    International Nuclear Information System (INIS)

    Medlin, W.L.

    1991-01-01

    This paper reports on the Tube Wave Reflection Log (TWRL) which is acoustic logging method which provides information about the height, location and conductivity of hydraulically induced fractures behind perforated casing. The TWRL tool consists of a transmitter and closely spaced receiver. The transmitter is driven with a short, low frequency tone burst to generate long wavelength tube waves which are little attenuated in unperforated casing. They are partially reflected when they pass perforated intervals communicating with a hydraulically induced fracture. The tool listens for such reflections for 0.1 seconds following each excitation burst. As the tool is moved uphole at logging speed, the transmitter is excited at each foot of depth. VDL displays of the TWRL records provide reflection traces whose projections define the uppermost and lower-most perforations communicating with the fracture. The strength of the reflections depends on the ease of fluid flow into the fracture and thus, is an indicator of fracture conductivity

  14. Smartphone log data in a qualitative perspective

    DEFF Research Database (Denmark)

    Ørmen, Jacob; Thorhauge, Anne Mette

    2015-01-01

    into studies of smartphones in everyday life. Through an illustrative study, we explore a more nuanced perspective on what can be considered “log data” and how these types of data can be collected and analysed. A qualitative approach to log data analysis offers researchers new opportunities to situate......Log data from smartphones have primarily been used in large-scale research designs to draw statistical inferences from hundreds or even thousands of participants. In this article, we argue that more qualitatively oriented designs can also benefit greatly from integrating these rich data sources...... serve as cues to instigate discussion and reflection as well as act as resources for contextualizing and organizing related empirical material. In the discussion, the advantages of a qualitative perspective for research designs are assessed in relation to issues of validity. Further perspectives...

  15. Characteristics of magnetic field induction inside a module of a magnetic separator ХАРАКТЕРИСТИКИ ИНДУКЦИИ ПОЛЯ В МОДУЛЕ МАГНИТНОГО СЕПАРАТОРА

    Directory of Open Access Journals (Sweden)

    Sandulyak Anna Aleksandrovna

    2013-05-01

    Full Text Available Characteristics of magnetic separators are analyzed in the article. Magnetic separators are used to treat various construction materials. Unfortunately, the nature of the magnetic field, generated in their operating zone, is generally not taken into account by their designers. Academic publications fail to provide any detailed basic characteristics of the field induction emitted by magnetic separators in the course of their operation.Magnetic systems of any magnetic separator have a modular structure; they consist of several modules. Single and opposite magnetic elements are usually integrated into one module within a system having permanent magnets. If opposite magnetic elements are used, magnetic field intensity inside the module increases.In this study, characteristics of magnetic induction for single magnetic elements inside various modules of magnetic separators were assessed in a laboratory experiment. Similar characteristics of magnetic induction for single and twin (opposite magnetic elements were compared. In the module consisting of two opposed magnetic elements, the magnetic field becomes stronger compared to the field of a single magnetic element. Magnetic induction in the module recedes as the distance between magnetic elements increases, because of the isolation of the field generated by the opposed magnetic elements.The authors have proven the feasibility and expediency of employment of the superposition principle used to obtain the resulting characteristics. It may be employed to substitute modeling by calculations.Экспериментально получены характеристики индукции магнитного поля для одиночных элементов в различных модулях магнитных сепараторов. Сопоставлены характеристики индукции магнитного поля для одиночных и спаренных магнитных

  16. Urofollitropin and ovulation induction

    NARCIS (Netherlands)

    van Wely, Madelon; Yding Andersen, Claus; Bayram, Neriman; van der Veen, Fulco

    2005-01-01

    Anovulation is a common cause of female infertility. Treatment for women with anovulation is aimed at induction of ovulation. Ovulation induction with follicle-stimulating hormone (FSH) is indicated in women with WHO type II anovulation in whom treatment with clomifene citrate (clomifene) has

  17. EVALUATION OF INDUCTANCE WITH ELECTRICAL WIRES

    Directory of Open Access Journals (Sweden)

    V. Kudry

    2016-08-01

    Full Text Available In this paper proved the possibility of developing passive electronic inductive elements based replace metal wire that is wound inductor, the wire is made of electret. The relative permeability of the electret S  10 000, several orders of magnitude greater than the permeability of conventional insulation materials, i < 10, resulting current in the wire acquires properties bias current. The essence of innovation is to replace the source of of magnetic induction flow that pervades the core of the coil. According to the theory of electrodynamics, current bias, in contrast to conduction current, generated no movement of charge along the wire, but the change of the charge in the local volume.Equivalence bias current and conduction current is manifested in the possibility of forming a magnetic field. The flow through magnetic induction coil core regardless of the current it generates, creates voltage at its ends.The paper also shows the numeric characteristics that determine the effective frequency range, specified the reason why electric a wire with і < 10 can not generate magnetic flux through the core and serve as a passive reactive component.

  18. Financial feasibility of a log sort yard handling small-diameter logs: A preliminary study

    Science.gov (United States)

    Han-Sup Han; E. M. (Ted) Bilek; John (Rusty) Dramm; Dan Loeffler; Dave Calkin

    2011-01-01

    The value and use of the trees removed in fuel reduction thinning and restoration treatments could be enhanced if the wood were effectively evaluated and sorted for quality and highest value before delivery to the next manufacturing destination. This article summarizes a preliminary financial feasibility analysis of a log sort yard that would serve as a log market to...

  19. Geothermal well log interpretation midterm report

    Energy Technology Data Exchange (ETDEWEB)

    Sanyal, S.K.; Wells, L.E.; Bickham, R.E.

    1979-02-01

    Reservoir types are defined according to fluid phase and temperature, lithology, geologic province, pore geometry, and salinity and fluid chemistry. Improvements are needed in lithology and porosity definition, fracture detection, and thermal evaluation for more accurate interpretation. Further efforts are directed toward improving diagnostic techniques for relating rock characteristics and log response, developing petrophysical models for geothermal systems, and developing thermal evaluation techniques. The Geothermal Well Log Interpretation study and report has concentrated only on hydrothermal geothermal reservoirs. Other geothermal reservoirs (hot dry rock, geopressured, etc.) are not considered.

  20. New portable neutron generator for well logging

    International Nuclear Information System (INIS)

    Chicanov, A.E.; Gromov, E. V.; Gulko, V. M.; Izmailov, A. V.

    1994-01-01

    The information about the design, investigation and testing of new well neutron generator for the pulse neutron logging (PNL) is given in this paper. The main physical characteristics of new PNL apparatus are: Neutron flux 2.10 sup 8 n/s ; Pulse frequency>=400 Hz; Diameter= 90 mm; Logging velocity >200 m/h; Number of probes = 2; Resource > 300 h. The generator were provided by gas-filled neutron accelerative tube named NTF-2. The perspective of application and optimization shown PNL apparatus are considered. (author)

  1. Analyzing Log Files using Data-Mining

    Directory of Open Access Journals (Sweden)

    Marius Mihut

    2008-01-01

    Full Text Available Information systems (i.e. servers, applications and communication devices create a large amount of monitoring data that are saved as log files. For analyzing them, a data-mining approach is helpful. This article presents the steps which are necessary for creating an ‘analyzing instrument’, based on an open source software called Waikato Environment for Knowledge Analysis (Weka [1]. For exemplification, a system log file created by a Windows-based operating system, is used as input file.

  2. Kaizen aplicado à logística

    OpenAIRE

    Santos, Ana Catarina Almeida

    2011-01-01

    O presente trabalho propõe alcançar um aumento de produtividade e consequente redução de custos e desperdícios ajudando o departamento logístico da Empresa Revigrés – Industria de Revestimentos de Grés, Lda, a tornar-se mais eficiente, através da aplicação da filosofia kaizen que propõe melhorias no desempenho por implementação de pequenas ações. O objetivo deste projeto é a melhoria do departamento logístico globalmente, para isso houve o recurso a pesquisas e levantamento ...

  3. Geophysical borehole logging test procedure: Final draft

    International Nuclear Information System (INIS)

    1986-09-01

    The purpose of geophysical borehole logging from the At-Depth Facility (ADF) is to provide information which will assist in characterizing the site geologic conditions and in classifying the engineering characteristics of the rock mass in the vicinity of the ADF. The direct goals of borehole logging include identification of lithologic units and their correlation from hole to hole, identification of fractured or otherwise porous or permeable zones, quantitative or semi-quantitative estimation of various formation properties, and evaluation of factors such as the borehole diameter and orientation. 11 figs., 4 tabs

  4. CS model coil experimental log book

    International Nuclear Information System (INIS)

    Nishijima, Gen; Sugimoto, Makoto; Nunoya, Yoshihiko; Wakabayashi, Hiroshi; Tsuji, Hiroshi

    2001-02-01

    Charging test of the ITER CS Model Coil which is the world's largest superconducting pulse coil and the CS Insert Coil had started at April 11, 2000 and had completed at August 18, 2000. In the campaign, total shot numbers were 356 and the size of the data file in the DAS (Data Acquisition System) was over 20 GB. This report is a database that consists of the log list and the log sheets of every shot. One can access the database, make a search, and browse results via Internet (http://1ogwww.naka.jaeri.go.jp). The database will be useful to quick search to choose necessary shots. (author)

  5. Perfil logístico de Colombia

    OpenAIRE

    Cardozo Maglioni, María Victoria; Lozano Suarez, María Goretty

    2012-01-01

    El presente documento ofrece un estudio del perfil logístico de Colombia con la finalidad de dar a conocer el estado de arte de las ciudades, puertos e infraestructura principal para facilitar la toma de decisiones de los empresarios. Para el desarrollo de este trabajo se determinaron a partir de un análisis competitivo del país; las principales ciudades y puertos; logrando establecer un inventario de maquinaria y equipo e infraestructura logística; enmarcados en retos ya establecidos en las ...

  6. Using open hole and cased-hole resistivity logs to monitor gas hydrate dissociation during a thermal test in the mallik 5L-38 research well, Mackenzie Delta, Canada

    Science.gov (United States)

    Anderson, B.I.; Collett, T.S.; Lewis, R.E.; Dubourg, I.

    2008-01-01

    Gas hydrates, which are naturally occurring ice-like combinations of gas and water, have the potential to provide vast amounts of natural gas from the world's oceans and polar regions. However, producing gas economically from hydrates entails major technical challenges. Proposed recovery methods such as dissociating or melting gas hydrates by heating or depressurization are currently being tested. One such test was conducted in northern Canada by the partners in the Mallik 2002 Gas Hydrate Production Research Well Program. This paper describes how resistivity logs were used to determine the size of the annular region of gas hydrate dissociation that occurred around the wellbore during the thermal test in the Mallik 5L-38 well. An open-hole logging suite, run prior to the thermal test, included array induction, array laterolog, nuclear magnetic resonance and 1.1-GHz electromagnetic propagation logs. The reservoir saturation tool was run both before and after the thermal test to monitor formation changes. A cased-hole formation resistivity log was run after the test.Baseline resistivity values in each formation layer (Rt) were established from the deep laterolog data. The resistivity in the region of gas hydrate dissociation near the wellbore (Rxo) was determined from electromagnetic propagation and reservoir saturation tool measurements. The radius of hydrate dissociation as a function of depth was then determined by means of iterative forward modeling of cased-hole formation resistivity tool response. The solution was obtained by varying the modeled dissociation radius until the modeled log overlaid the field log. Pretest gas hydrate production computer simulations had predicted that dissociation would take place at a uniform radius over the 13-ft test interval. However, the post-test resistivity modeling showed that this was not the case. The resistivity-derived dissociation radius was greatest near the outlet of the pipe that circulated hot water in the wellbore

  7. Amorphous alloy induction core performance in pulse condition

    International Nuclear Information System (INIS)

    Cheng Hao; Zhang Linwen; Cheng Nian'an

    2002-01-01

    The requirements and the characteristics of magnetic material (amorphous and ferrite) in linac induction accelerators (LIA) are described briefly in this paper. Experimentations are done base on the static conditions, in additional more researches are done in the pulse condition. Come to the conclusion that both materials have higher saturation magnetic swing under pulse conditions in comparison with their static conditions

  8. Inductance loop and partial

    CERN Document Server

    Paul, Clayton R

    2010-01-01

    "Inductance is an unprecedented text, thoroughly discussing "loop" inductance as well as the increasingly important "partial" inductance. These concepts and their proper calculation are crucial in designing modern high-speed digital systems. World-renowned leader in electromagnetics Clayton Paul provides the knowledge and tools necessary to understand and calculate inductance." "With the present and increasing emphasis on high-speed digital systems and high-frequency analog systems, it is imperative that system designers develop an intimate understanding of the concepts and methods in this book. Inductance is a much-needed textbook designed for senior and graduate-level engineering students, as well as a hands-on guide for working engineers and professionals engaged in the design of high-speed digital and high-frequency analog systems."--Jacket.

  9. Extracting useful knowledge from event logs

    DEFF Research Database (Denmark)

    Djenouri, Youcef; Belhadi, Asma; Fournier-Viger, Philippe

    2018-01-01

    Business process analysis is a key activity that aims at increasing the efficiency of business operations. In recent years, several data mining based methods have been designed for discovering interesting patterns in event logs. A popular type of methods consists of applying frequent itemset mini...

  10. Potential for shared log transport services

    Science.gov (United States)

    Tim McDonald; Steve Taylor; Jorge Valenzuela

    2001-01-01

    A simulation model of a log transport logistics network was developed. The model could be structured to either share truck capacity among a group of loggers, or to assign a fixed number of trucks to individual loggers. Another variation of the model allowed the use of a staging yard to set out loaded trailers and deliver them to destinations using dedicated shuttle...

  11. Identifying unstable sites on logging roads

    Science.gov (United States)

    R. M. Rice; J. Lewis

    1986-01-01

    Logging roads are an important source of forestry-related erosion. The amount of erosion on a forest road is determined by the interaction between how the road is constructed and maintained and the environment in which it is built. The roads in this study were constructed with large bulldozers, and most excavated material was sidecast. The roads studied were...

  12. Narrating Illegal Logging Across the Globe

    DEFF Research Database (Denmark)

    Winkel, Georg; Leipold, Sina; Buhmann, Karin

    2017-01-01

    In the last decade illegal logging has triggered the attention of policy makers and scholars of international forest governance. The issue is multifaceted, involving aspects of social and environmental sustainability, development, trade, access to markets and competitiveness. A vivid academic deb...

  13. Modelling tropical forests response to logging

    Science.gov (United States)

    Cazzolla Gatti, Roberto; Di Paola, Arianna; Valentini, Riccardo; Paparella, Francesco

    2013-04-01

    Tropical rainforests are among the most threatened ecosystems by large-scale fragmentation due to human activity such as heavy logging and agricultural clearance. Although, they provide crucial ecosystem goods and services, such as sequestering carbon from the atmosphere, protecting watersheds and conserving biodiversity. In several countries forest resource extraction has experienced a shift from clearcutting to selective logging to maintain a significant forest cover and understock of living biomass. However the knowledge on the short and long-term effects of removing selected species in tropical rainforest are scarce and need to be further investigated. One of the main effects of selective logging on forest dynamics seems to be the local disturbance which involve the invasion of open space by weed, vines and climbers at the expense of the late-successional state cenosis. We present a simple deterministic model that describes the dynamics of tropical rainforest subject to selective logging to understand how and why weeds displace native species. We argue that the selective removal of tallest tropical trees carries out gaps of light that allow weeds, vines and climbers to prevail on native species, inhibiting the possibility of recovery of the original vegetation. Our results show that different regime shifts may occur depending on the type of forest management adopted. This hypothesis is supported by a dataset of trees height and weed/vines cover that we collected from 9 plots located in Central and West Africa both in untouched and managed areas.

  14. ADN* Density log estimation Using Rockcell*

    International Nuclear Information System (INIS)

    Okuku, C.; Iloghalu, Emeka. M.; Omotayo, O.

    2003-01-01

    This work is intended to inform on the possibilities of estimating good density data in zones associated with sliding in a reservoir with ADN* tool with or without ADOS in string in cases where repeat sections were not done, possibly due to hole stability or directional concerns. This procedure has been equally used to obtain a better density data in corkscrew holes. Density data (ROBB) was recomputed using neural network in RockCell* to estimate the density over zones of interest. RockCell* is a Schlumberger software that has neural network functionally which can be used to estimate missing logs using the combination of the responses of other log curves and intervals that are not affected by sliding. In this work, an interval was selected and within this interval twelve litho zones were defined using the unsupervised neural network. From this a training set was selected based on intervals of very good log responses outside the sliding zones. This training set was used to train and run the neural network for a specific lithostratigraphic interval. The results matched the known good density curve. Then after this, an estimation of the density curve was done using the supervised neural network. The output from this estimation matched very closely in the good portions of the log, thus providing some density measurements in the sliding zone. This methodology provides a scientific solution to missing data during the process of Formation evaluation

  15. Changes in the Logging Labor Force

    Science.gov (United States)

    Charles H. Wolf; Jean W. Nolley

    1977-01-01

    Employment in the logging industry dropped 28 percent between 1950 and 1970, while output of industrial roundwood increased 31 percent. Today's loggers are older, better educated, and more skilled. A large proportion are self-employed, many work less than a full year, and a substantial number have incomes below the poverty level. Mechanization of timber harvesting...

  16. Alaska midgrade logs: supply and offshore demand.

    Science.gov (United States)

    Donald F. Flora; Wendy J. McGinnis

    1989-01-01

    The outlook for shipments and prices of export logs from Alaska differs significantly by grade (quality class). For the majority lying in the middle of the value range, the trend of prices is projected to increase $200 per thousand board feet, or about 55 percent, by 2000. Shipments are expected to rise about 30 percent by 1995 and then subside about 10 percent. These...

  17. Analyzing Grid Log Data with Affinity Propagation

    NARCIS (Netherlands)

    Modena, G.; van Someren, M.W.; Ali, M; Bosse, T.; Hindriks, K.V.; Hoogendoorn, M.; Jonker, C.M; Treur, J.

    2013-01-01

    In this paper we present an unsupervised learning approach to detect meaningful job traffic patterns in Grid log data. Manual anomaly detection on modern Grid environments is troublesome given their increasing complexity, the distributed, dynamic topology of the network and heterogeneity of the jobs

  18. Exploration and grade control neutron logging

    International Nuclear Information System (INIS)

    Eisler, P.L.

    1982-01-01

    Techniques used in neutron logging in boreholes are discussed. They include the application of neutron probes to porosity measurements, to lithological determinations based on macroscopic cross-section measurements and measurements of the concentration of chemical constituents in rocks and ores

  19. Explorations in statistics: the log transformation.

    Science.gov (United States)

    Curran-Everett, Douglas

    2018-06-01

    Learning about statistics is a lot like learning about science: the learning is more meaningful if you can actively explore. This thirteenth installment of Explorations in Statistics explores the log transformation, an established technique that rescales the actual observations from an experiment so that the assumptions of some statistical analysis are better met. A general assumption in statistics is that the variability of some response Y is homogeneous across groups or across some predictor variable X. If the variability-the standard deviation-varies in rough proportion to the mean value of Y, a log transformation can equalize the standard deviations. Moreover, if the actual observations from an experiment conform to a skewed distribution, then a log transformation can make the theoretical distribution of the sample mean more consistent with a normal distribution. This is important: the results of a one-sample t test are meaningful only if the theoretical distribution of the sample mean is roughly normal. If we log-transform our observations, then we want to confirm the transformation was useful. We can do this if we use the Box-Cox method, if we bootstrap the sample mean and the statistic t itself, and if we assess the residual plots from the statistical model of the actual and transformed sample observations.

  20. Apache Flume distributed log collection for Hadoop

    CERN Document Server

    D'Souza, Subas

    2013-01-01

    A starter guide that covers Apache Flume in detail.Apache Flume: Distributed Log Collection for Hadoop is intended for people who are responsible for moving datasets into Hadoop in a timely and reliable manner like software engineers, database administrators, and data warehouse administrators