WorldWideScience

Sample records for macromolecular contrast medium

  1. Dendrimer-based Macromolecular MRI Contrast Agents: Characteristics and Application

    Directory of Open Access Journals (Sweden)

    Hisataka Kobayashi

    2003-01-01

    Full Text Available Numerous macromolecular MRI contrast agents prepared employing relatively simple chemistry may be readily available that can provide sufficient enhancement for multiple applications. These agents operate using a ~100-fold lower concentration of gadolinium ions in comparison to the necessary concentration of iodine employed in CT imaging. Herein, we describe some of the general potential directions of macromolecular MRI contrast agents using our recently reported families of dendrimer-based agents as examples. Changes in molecular size altered the route of excretion. Smaller-sized contrast agents less than 60 kDa molecular weight were excreted through the kidney resulting in these agents being potentially suitable as functional renal contrast agents. Hydrophilic and larger-sized contrast agents were found better suited for use as blood pool contrast agents. Hydrophobic variants formed with polypropylenimine diaminobutane dendrimer cores created liver contrast agents. Larger hydrophilic agents are useful for lymphatic imaging. Finally, contrast agents conjugated with either monoclonal antibodies or with avidin are able to function as tumor-specific contrast agents, which also might be employed as therapeutic drugs for either gadolinium neutron capture therapy or in conjunction with radioimmunotherapy.

  2. Polydisulfide Manganese(II) Complexes as Non-Gadolinium Biodegradable Macromolecular MRI Contrast Agents

    Science.gov (United States)

    Ye, Zhen; Jeong, Eun-Kee; Wu, Xueming; Tan, Mingqian; Yin, Shouyu; Lu, Zheng-Rong

    2011-01-01

    Purpose To develop safe and effective manganese(II) based biodegradable macromolecular MRI contrast agents. Materials and Methods In this study, we synthesized and characterized two polydisulfide manganese(II) complexes, Mn-DTPA cystamine copolymers and Mn-EDTA cystamine copolymers, as new biodegradable macromolecular MRI contrast agents. The contrast enhancement of the two manganese based contrast agents were evaluated in mice bearing MDA-MB-231 human breast carcinoma xenografts, in comparison with MnCl2. Results The T1 and T2 relaxivities were 4.74 and 10.38 mM−1s−1 per manganese at 3T for Mn-DTPA cystamine copolymers (Mn=30.50 kDa) and 6.41 and 9.72 mM−1s−1 for Mn-EDTA cystamine copolymers (Mn= 61.80 kDa). Both polydisulfide Mn(II) complexes showed significant liver, myocardium and tumor enhancement. Conclusion The manganese based polydisulfide contrast agents have a potential to be developed as alternative non-gadolinium contrast agents for MR cancer and myocardium imaging. PMID:22031457

  3. A technique for determining the deuterium/hydrogen contrast map in neutron macromolecular crystallography.

    Science.gov (United States)

    Chatake, Toshiyuki; Fujiwara, Satoru

    2016-01-01

    A difference in the neutron scattering length between hydrogen and deuterium leads to a high density contrast in neutron Fourier maps. In this study, a technique for determining the deuterium/hydrogen (D/H) contrast map in neutron macromolecular crystallography is developed and evaluated using ribonuclease A. The contrast map between the D2O-solvent and H2O-solvent crystals is calculated in real space, rather than in reciprocal space as performed in previous neutron D/H contrast crystallography. The present technique can thus utilize all of the amplitudes of the neutron structure factors for both D2O-solvent and H2O-solvent crystals. The neutron D/H contrast maps clearly demonstrate the powerful detectability of H/D exchange in proteins. In fact, alternative protonation states and alternative conformations of hydroxyl groups are observed at medium resolution (1.8 Å). Moreover, water molecules can be categorized into three types according to their tendency towards rotational disorder. These results directly indicate improvement in the neutron crystal structure analysis. This technique is suitable for incorporation into the standard structure-determination process used in neutron protein crystallography; consequently, more precise and efficient determination of the D-atom positions is possible using a combination of this D/H contrast technique and standard neutron structure-determination protocols.

  4. Macromolecular and dendrimer-based magnetic resonance contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Bumb, Ambika; Brechbiel, Martin W. (Radiation Oncology Branch, National Cancer Inst., National Inst. of Health, Bethesda, MD (United States)), e-mail: pchoyke@mail.nih.gov; Choyke, Peter (Molecular Imaging Program, National Cancer Inst., National Inst. of Health, Bethesda, MD (United States))

    2010-09-15

    Magnetic resonance imaging (MRI) is a powerful imaging modality that can provide an assessment of function or molecular expression in tandem with anatomic detail. Over the last 20-25 years, a number of gadolinium-based MR contrast agents have been developed to enhance signal by altering proton relaxation properties. This review explores a range of these agents from small molecule chelates, such as Gd-DTPA and Gd-DOTA, to macromolecular structures composed of albumin, polylysine, polysaccharides (dextran, inulin, starch), poly(ethylene glycol), copolymers of cystamine and cystine with GD-DTPA, and various dendritic structures based on polyamidoamine and polylysine (Gadomers). The synthesis, structure, biodistribution, and targeting of dendrimer-based MR contrast agents are also discussed

  5. The contrasting effect of macromolecular crowding on amyloid fibril formation.

    Directory of Open Access Journals (Sweden)

    Qian Ma

    Full Text Available Amyloid fibrils associated with neurodegenerative diseases can be considered biologically relevant failures of cellular quality control mechanisms. It is known that in vivo human Tau protein, human prion protein, and human copper, zinc superoxide dismutase (SOD1 have the tendency to form fibril deposits in a variety of tissues and they are associated with different neurodegenerative diseases, while rabbit prion protein and hen egg white lysozyme do not readily form fibrils and are unlikely to cause neurodegenerative diseases. In this study, we have investigated the contrasting effect of macromolecular crowding on fibril formation of different proteins.As revealed by assays based on thioflavin T binding and turbidity, human Tau fragments, when phosphorylated by glycogen synthase kinase-3β, do not form filaments in the absence of a crowding agent but do form fibrils in the presence of a crowding agent, and the presence of a strong crowding agent dramatically promotes amyloid fibril formation of human prion protein and its two pathogenic mutants E196K and D178N. Such an enhancing effect of macromolecular crowding on fibril formation is also observed for a pathological human SOD1 mutant A4V. On the other hand, rabbit prion protein and hen lysozyme do not form amyloid fibrils when a crowding agent at 300 g/l is used but do form fibrils in the absence of a crowding agent. Furthermore, aggregation of these two proteins is remarkably inhibited by Ficoll 70 and dextran 70 at 200 g/l.We suggest that proteins associated with neurodegenerative diseases are more likely to form amyloid fibrils under crowded conditions than in dilute solutions. By contrast, some of the proteins that are not neurodegenerative disease-associated are unlikely to misfold in crowded physiological environments. A possible explanation for the contrasting effect of macromolecular crowding on these two sets of proteins (amyloidogenic proteins and non-amyloidogenic proteins has been

  6. Macromolecular contrast agents for MR mammography: current status

    International Nuclear Information System (INIS)

    Daldrup-Link, Heike E.; Brasch, Robert C.

    2003-01-01

    Macromolecular contrast media (MMCM) encompass a new class of diagnostic drugs that can be applied with dynamic MRI to extract both physiologic and morphologic information in breast lesions. Kinetic analysis of dynamic MMCM-enhanced MR data in breast tumor patients provides useful estimates of tumor blood volume and microvascular permeability, typically increased in cancer. These tumor characteristics can be applied to differentiate benign from malignant lesions, to define the angiogenesis status of cancers, and to monitor tumor response to therapy. The most immediate challenge to the development of MMCM-enhanced mammography is the identification of those candidate compounds that demonstrate the requisite long intravascular distribution and have the high tolerance necessary for clinical use. Potential mammographic applications and limitations of various MMCM, defined by either experimental animal testing or clinical testing in patients, are reviewed in this article. (orig.)

  7. Incompatibility of Contrast Medium and Trisodium Citrate

    International Nuclear Information System (INIS)

    Delcour, Christian; Bruninx, Guy

    2013-01-01

    To test the compatibility of trisodium citrate, a catheter lock solution, with iodinated contrast medium. Iohexol, iobitridol, iodixanol, ioxaglate, ioxithalamate, iomeprol, and iopromide were tested. In all tests, 2 ml of contrast medium were mixed with 2 ml of trisodium citrate solution. Iodixanol and ioxaglate provoked a highly viscous gluelike precipitation when mixed with trisodium citrate. A brief transient precipitate was observed with iohexol, iomeprol, and ioxithalamate. Permanent precipitation occurred with iobitridol and iopromide. One must be aware of the potential for precipitation when contrast medium is mixed with trisodium citrate solution. Before trisodium citrate solution is injected, the catheter should be thoroughly flushed with saline if a contrast medium has previously been injected through it.

  8. Permeability to macromolecular contrast media quantified by dynamic MRI correlates with tumor tissue assays of vascular endothelial growth factor (VEGF)

    International Nuclear Information System (INIS)

    Cyran, Clemens C.; Sennino, Barbara; Fu, Yanjun; Rogut, Victor; Shames, David M.; Chaopathomkul, Bundit; Wendland, Michael F.; McDonald, Donald M.; Brasch, Robert C.; Raatschen, Hans-Juergen

    2012-01-01

    Purpose: To correlate dynamic MRI assays of macromolecular endothelial permeability with microscopic area–density measurements of vascular endothelial growth factor (VEGF) in tumors. Methods and material: This study compared tumor xenografts from two different human cancer cell lines, MDA-MB-231 tumors (n = 5), and MDA-MB-435 (n = 8), reported to express respectively higher and lower levels of VEGF. Dynamic MRI was enhanced by a prototype macromolecular contrast medium (MMCM), albumin-(Gd-DTPA)35. Quantitative estimates of tumor microvascular permeability (K PS ; μl/min × 100 cm 3 ), obtained using a two-compartment kinetic model, were correlated with immunohistochemical measurements of VEGF in each tumor. Results: Mean K PS was 2.4 times greater in MDA-MB-231 tumors (K PS = 58 ± 30.9 μl/min × 100 cm 3 ) than in MDA-MB-435 tumors (K PS = 24 ± 8.4 μl/min × 100 cm 3 ) (p < 0.05). Correspondingly, the area–density of VEGF in MDA-MB-231 tumors was 2.6 times greater (27.3 ± 2.2%, p < 0.05) than in MDA-MB-435 cancers (10.5 ± 0.5%, p < 0.05). Considering all tumors without regard to cell type, a significant positive correlation (r = 0.67, p < 0.05) was observed between MRI-estimated endothelial permeability and VEGF immunoreactivity. Conclusion: Correlation of MRI assays of endothelial permeability to a MMCM and VEGF immunoreactivity of tumors support the hypothesis that VEGF is a major contributor to increased macromolecular permeability in cancers. When applied clinically, the MMCM-enhanced MRI approach could help to optimize the appropriate application of VEGF-inhibiting therapy on an individual patient basis.

  9. Roentgen contrast medium

    International Nuclear Information System (INIS)

    Tamborski, C.

    1989-01-01

    The patent deals with a roentgen contrast medium containing a perfluorinebrominealkylether of the formula C m F 2m+1 OC n F 2n Br dispersed in water, preferentially in the presence of a non-ionic dispersing agent such as a fluorinated amidoaminoxide. 2 tabs

  10. Macromolecular contrast media. A new approach for characterising breast tumors with MR-mammography

    International Nuclear Information System (INIS)

    Daldrup, H.E.; Gossmann, A.; Koeln Univ.; Wendland, M.; Brasch, R.C.; Rosenau, W.

    1997-01-01

    The value of macromolecular contrast agents (MMCM) for the characterization of benign and malignant breast tumors will be demonstrated in this review. Animal studies suggest a high potential of MMCM to increase the specificity of MR-mammography. The concept of tumor differentiation is based on the pathological hyperpermeability of microvessels in malignant tumors. MMCM show a leak into the interstitium of carcinomas, whereas they are confined to the intravascular space in benign tumors. Capabilities and limitations of the MMCM-prototype. Albumin-Gd-DTPA, for breast tumor characterization will be summarized and compared to the standard low molecular weight contrast agent Gd-DTPA. Initial experience with new MMCM, such as Dendrimers, Gd-DTPA-Polylysine and MS-325 will be outlined. The potential of 'blood-pool'-iron oxides, such as AMI-227 for the evaluation of tumor microvascular permeabilities will be discussed. (orig.) [de

  11. A neutral polydisulfide containing Gd(III) DOTA monoamide as a redox-sensitive biodegradable macromolecular MRI contrast agent.

    Science.gov (United States)

    Ye, Zhen; Zhou, Zhuxian; Ayat, Nadia; Wu, Xueming; Jin, Erlei; Shi, Xiaoyue; Lu, Zheng-Rong

    2016-01-01

    This work aims to develop safe and effective gadolinium (III)-based biodegradable macromolecular MRI contrast agents for blood pool and cancer imaging. A neutral polydisulfide containing macrocyclic Gd-DOTA monoamide (GOLS) was synthesized and characterized. In addition to studying the in vitro degradation of GOLS, its kinetic stability was also investigated in an in vivo model. The efficacy of GOLS for contrast-enhanced MRI was examined with female BALB/c mice bearing 4T1 breast cancer xenografts. The pharmacokinetics, biodistribution, and metabolism of GOLS were also determined in mice. GOLS has an apparent molecular weight of 23.0 kDa with T1 relaxivities of 7.20 mM(-1) s(-1) per Gd at 1.5 T, and 6.62 mM(-1) s(-1) at 7.0 T. GOLS had high kinetic inertness against transmetallation with Zn(2+) ions, and its polymer backbone was readily cleaved by L-cysteine. The agent showed improved efficacy for blood pool and tumor MR imaging. The structural effect on biodistribution and in vivo chelation stability was assessed by comparing GOLS with Gd(HP-DO3A), a negatively charged polydisulfide containing Gd-DOTA monoamide GODC, and a polydisulfide containing Gd-DTPA-bisamide (GDCC). GOLS showed high in vivo chelation stability and minimal tissue deposition of gadolinium. The biodegradable macromolecular contrast agent GOLS is a promising polymeric contrast agent for clinical MR cardiovascular imaging and cancer imaging. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Risk of application of contrast medium in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wende, S.; Speck, U.

    1981-06-01

    The paper deals with the risk associated with the application of contrast medium in CT. The risk is to be seen in intolerance reactions, such as allergic or circulatory reactions and neurotoxic side-effects. In this paper the problems of renal failure caused by the injection of contrast medium are given special attention. Furthermore an iodine-induced hyperthyreosis might result. Especially the possible disturbance of the kidney function means that contrast medium should not be applied arbitrarily and that the examination should be done only by experienced staff. Furthermore the indication for the application of contrast medium in CT should be strictly qualified.

  13. Risk of application of contrast medium in computed tomography

    International Nuclear Information System (INIS)

    Wende, S.; Speck, U.; Schering A.G., Berlin

    1981-01-01

    The paper deals with the risk associated with the application of contrast medium in CT. The risk is to be seen in intolerance reactions, such as allergic or circulatory reactions and neurotoxic side-effects. In this paper the problems of renal failure caused by the injection of contrast medium are given special attention. Furthermore an iodine-induced hyperthyreosis might result. Especially the possible disturbance of the kidney function means that contrast medium should not be applied arbitrarily and that the examination should be done only by experienced staff. Furthermore the indication for the application of contrast medium in CT should be strictly qualified. (orig.) [de

  14. Dynamic contrast-enhanced MRI using a macromolecular MR contrast agent (P792): Evaluation of antivascular drug effect in a rabbit VX2 liver tumor model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Sun [Dept. of Radiology, Konkuk University School of Medicine, Seoul (Korea, Republic of); Han, Joon Koo; Lee, Jeong Min; Woo, Sung Min; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Young Il [Dept. of Radiology, Sheikh Khalifa Specialty Hospital, Ras Al Khaimah (United Arab Emirates); Choi, Jin Young [Dept. of Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-10-15

    To evaluate the utility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using macromolecular contrast agent (P792) for assessment of vascular disrupting drug effect in rabbit VX2 liver tumor models. This study was approved by our Institutional Animal Care and Use Committee. DCE-MRI was performed with 3-T scanner in 13 VX2 liver tumor-bearing rabbits, before, 4 hours after, and 24 hours after administration of vascular disrupting agent (VDA), using gadomelitol (P792, n = 7) or low molecular weight contrast agent (gadoterate meglumine [Gd-DOTA], n = 6). P792 was injected at a of dose 0.05 mmol/kg, while that of Gd-DOTA was 0.2 mmol/kg. DCE-MRI parameters including volume transfer coefficient (Ktrans) and initial area under the gadolinium concentration-time curve until 60 seconds (iAUC) of tumors were compared between the 2 groups at each time point. DCE-MRI parameters were correlated with tumor histopathology. Reproducibility in measurement of DCE-MRI parameters and image quality of source MR were compared between groups. P792 group showed a more prominent decrease in Ktrans and iAUC at 4 hours and 24 hours, as compared to the Gd-DOTA group. Changes in DCE-MRI parameters showed a weak correlation with histologic parameters (necrotic fraction and microvessel density) in both groups. Reproducibility of DCE-MRI parameters and overall image quality was not significantly better in the P792 group, as compared to the Gd-DOTA group. Dynamic contrast-enhanced magnetic resonance imaging using a macromolecular contrast agent shows changes of hepatic perfusion more clearly after administration of the VDA. Gadolinium was required at smaller doses than a low molecular contrast agent.

  15. Dynamic contrast-enhanced MRI using a macromolecular MR contrast agent (P792): Evaluation of antivascular drug effect in a rabbit VX2 liver tumor model

    International Nuclear Information System (INIS)

    Park, Hee Sun; Han, Joon Koo; Lee, Jeong Min; Woo, Sung Min; Choi, Byung Ihn; Kim, Young Il; Choi, Jin Young

    2015-01-01

    To evaluate the utility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using macromolecular contrast agent (P792) for assessment of vascular disrupting drug effect in rabbit VX2 liver tumor models. This study was approved by our Institutional Animal Care and Use Committee. DCE-MRI was performed with 3-T scanner in 13 VX2 liver tumor-bearing rabbits, before, 4 hours after, and 24 hours after administration of vascular disrupting agent (VDA), using gadomelitol (P792, n = 7) or low molecular weight contrast agent (gadoterate meglumine [Gd-DOTA], n = 6). P792 was injected at a of dose 0.05 mmol/kg, while that of Gd-DOTA was 0.2 mmol/kg. DCE-MRI parameters including volume transfer coefficient (Ktrans) and initial area under the gadolinium concentration-time curve until 60 seconds (iAUC) of tumors were compared between the 2 groups at each time point. DCE-MRI parameters were correlated with tumor histopathology. Reproducibility in measurement of DCE-MRI parameters and image quality of source MR were compared between groups. P792 group showed a more prominent decrease in Ktrans and iAUC at 4 hours and 24 hours, as compared to the Gd-DOTA group. Changes in DCE-MRI parameters showed a weak correlation with histologic parameters (necrotic fraction and microvessel density) in both groups. Reproducibility of DCE-MRI parameters and overall image quality was not significantly better in the P792 group, as compared to the Gd-DOTA group. Dynamic contrast-enhanced magnetic resonance imaging using a macromolecular contrast agent shows changes of hepatic perfusion more clearly after administration of the VDA. Gadolinium was required at smaller doses than a low molecular contrast agent

  16. Effects of computed tomography contrast medium factors on contrast enhancement

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi; Okuda, Itsuko

    2011-01-01

    The various nonionic iodinated contrast media used in contrast computed tomography (CT) studies differ in terms of their composition, characteristics, and iodine concentration (mgI/ml), as well as the volume injected (ml). Compared with ionic iodinated contrast media, nonionic iodinated contrast media are low-osmolar agents, with different agents having different osmotic pressures. Using a custom-made phantom incorporating a semipermeable membrane, the osmotic flow rate (hounsfield unit (HU)/s) could easily be measured based on the observed increase in CT numbers, and the relationship between the osmotic pressure and the osmotic flow rate could be obtained (r 2 =0.84). In addition, taking the effects of patient size into consideration, the levels of contrast enhancement in the abdominal aorta (AA) and inferior vena cava (IVC) were compared among four types of CT contrast medium. The results showed differences in contrast enhancement in the IVC during the equilibrium phase depending on the type of contrast medium used. It was found that the factors responsible for the differences observed in enhancement in the IVC were the osmotic flow rate and the volume of the blood flow pathways in the circulatory system. It is therefore considered that the reproducibility of contrast enhancement is likely to be reduced in the examination of parenchymal organs, in which scanning must be performed during the equilibrium phase, even if the amount of iodine injected per unit body weight (mgI/kg) is maintained at a specified level. (author)

  17. Clinical experience with a non-ionic contrast medium (ultravist) in left ventriculography

    International Nuclear Information System (INIS)

    Lee, Ghi Jai; Park, Jae Hyung; Soe, Gwy Suk; Hong, Ju Hee; Han, Man Chung

    1988-01-01

    Non-ionic contrast medium, iopromide (Ultravist), was compared with ionic contrast medium, ioxitalamate (Telebrix), for efficacy and safety in 63 patients undergoing left ventriculography. In all patients, adverse symptoms and signs including pain, heat sense, nausea, vomiting, etc., were checked during and shortly after the injection. Blood pressure, heart rate, EKG and left ventricular pressure were also monitored during the study, and CBC, UA, BUN and creatinine were checked before and 24 hours after the study. The cineangiographic films were analysed and compared by 2 radiologists for the quality. Serious adverse effect did not occur in any case. Minor effects, especially nausea, were lee frequently caused by non-ionic contrast medium than by ionic contrast medium, and heat sense to non-ionic contrast medium was less severe than to ionic contrast medium. Except slightly elevated LVEDP at 1,5 minutes after the study in patients given ionic contrast medium, there was no significant change of electrophysiologic parameters and laboratory findings in both groups. In regard to image quality, there was no significant difference between ionic and non-ionic contrast medium. Thus non-ionic contrast medium, iopromide, appears to be safer for use in left ventriculography than the conventional ionic contrast medium, particularly in those patients at high risk of adverse effects.

  18. Crowding-facilitated macromolecular transport in attractive micropost arrays.

    Science.gov (United States)

    Chien, Fan-Tso; Lin, Po-Keng; Chien, Wei; Hung, Cheng-Hsiang; Yu, Ming-Hung; Chou, Chia-Fu; Chen, Yeng-Long

    2017-05-02

    Our study of DNA dynamics in weakly attractive nanofabricated post arrays revealed crowding enhances polymer transport, contrary to hindered transport in repulsive medium. The coupling of DNA diffusion and adsorption to the microposts results in more frequent cross-post hopping and increased long-term diffusivity with increased crowding density. We performed Langevin dynamics simulations and found maximum long-term diffusivity in post arrays with gap sizes comparable to the polymer radius of gyration. We found that macromolecular transport in weakly attractive post arrays is faster than in non-attractive dense medium. Furthermore, we employed hidden Markov analysis to determine the transition of macromolecular adsorption-desorption on posts and hopping between posts. The apparent free energy barriers are comparable to theoretical estimates determined from polymer conformational fluctuations.

  19. Gd-DTPA L-cystine bisamide copolymers as novel biodegradable macromolecular contrast agents for MR blood pool imaging.

    Science.gov (United States)

    Kaneshiro, Todd L; Ke, Tianyi; Jeong, Eun-Kee; Parker, Dennis L; Lu, Zheng-Rong

    2006-06-01

    The purpose of this study was to synthesize biodegradable Gd-DTPA L-cystine bisamide copolymers (GCAC) as safe and effective, macromolecular contrast agents for magnetic resonance imaging (MRI) and to evaluate their biodegradability and efficacy in MR blood pool imaging in an animal model. Three new biodegradable GCAC with different substituents at the cystine bisamide [R = H (GCAC), CH2CH2CH3 (Gd-DTPA L-cystine bispropyl amide copolymers, GCPC), and CH(CH3)2 (Gd-DTPA cystine bisisopropyl copolymers, GCIC)] were prepared by the condensation copolymerization of diethylenetriamine pentaacetic acid (DTPA) dianhydride with cystine bisamide or bisalkyl amides, followed by complexation with gadolinium triacetate. The degradability of the agents was studied in vitro by incubation in 15 microM cysteine and in vivo with Sprague-Dawley rats. The kinetics of in vivo contrast enhancement was investigated in Sprague-Dawley rats on a Siemens Trio 3 T scanner. The apparent molecular weight of the polydisulfide Gd(III) chelates ranged from 22 to 25 kDa. The longitudinal (T1) relaxivities of GCAC, GCPC, and GCIC were 4.37, 5.28, and 5.56 mM(-1) s(-1) at 3 T, respectively. The polymeric ligands and polymeric Gd(III) chelates readily degraded into smaller molecules in incubation with 15 microM cysteine via disulfide-thiol exchange reactions. The in vitro degradation rates of both the polymeric ligands and macromolecular Gd(III) chelates decreased as the steric effect around the disulfide bonds increased. The agents readily degraded in vivo, and the catabolic degradation products were detected in rat urine samples collected after intravenous injection. The agents showed strong contrast enhancement in the blood pool, major organs, and tissues at a dose of 0.1 mmol Gd/kg. The difference of their in vitro degradability did not significantly alter the kinetics of in vivo contrast enhancement of the agents. These novel GCAC are promising contrast agents for cardiovascular and tumor MRI

  20. Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT

    International Nuclear Information System (INIS)

    Berther, Ralph; Eckhardt, Boris; Zollikofer, Christoph L.; Patak, Michael A.; Erturk, Sukru M.

    2008-01-01

    To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P<0.001), homogeneity of the luminal content (P<0.001), delineation of the bowel-wall to the lumen (P<0.001) and to the mesentery (P<0.001) and artifacts (P<0.001), leading to a significant better overall image quality (P<0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P<0.001) and wall to lumen delineation (P<0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population. (orig.)

  1. Radiculography with water-soluble contraste medium

    International Nuclear Information System (INIS)

    Araujo Pinheiro, R.S. de

    1987-01-01

    The etiologic diagnosis of the lumbar pain is discussed. The radiculography with water-soluble contrast medium is used and 250 cases are studied. Some practical criteria of indication executation and interpretation of the examination are reported. (M.A.C.) [pt

  2. Comparison of renal toxicity after injection of CT contrast medium and MR contrast medium: change of renal function in acute renal failure rat models

    International Nuclear Information System (INIS)

    Han, Young min; Lee, Young Hwan; Kim, Sang Won; Jin, Kong Young; Kim, Won; Chung, Gyung Ho

    2002-01-01

    To determine renal toxicity through changes in renal function after the injection of CT and MRI contrast media into rats in which acute renal failure (ARF) was induced. To cause acute renal failure, the abdominal cavity of 110 male rats each weighing 250-300 gm was opened via a midline incision under anesthesia. Microvascular clamps were placed on both renal arteries and veins to completely block renal blood flow for 45 minutes, and were then removed, allowing blood flow to return to the kidneys. ARF, defined as a two-fold difference in the creatinine level before ARF and 48 hours after, was successfully induced in 60 of the rats. These were divided into two groups: one was injected with CT contrast medium and the other with MRI contrast medium. Each CT and MRI group was divided into a low dose (0.5 cc/kg, 0.2 ml/kg), standard dose (2 cc/kg, 0.8 ml/kg), and high dose (8 cc/kg, 3.2 ml/kg) sub-group; thus, there was a total of six groups with ten rats in each. Blood samples were obtained before ARF, 48 hours after, and 48 hours after contrast injection, and CT scanning and MRI were performed after blood sampling at 48 hours. In each group, creatinine levels 48 hours after contrast injection were compared by means of the ANOVA test. There were no significant differences in creatinine levels between the CT and MRI contrast medium groups (p=0.116), nor between the animals to which different doses of CT and MRI contrast medium, were administered. After both standard and high doses, CT and MRI provided good images. In rats in which acute renal failure was induced, renal function did not change according to whether CT or MRI contrast medium was injected. Thus, the two media induce similar levels of toxicity

  3. Enhanced conjugation stability and blood circulation time of macromolecular gadolinium-DTPA contrast agent.

    Science.gov (United States)

    Jenjob, Ratchapol; Kun, Na; Ghee, Jung Yeon; Shen, Zheyu; Wu, Xiaoxia; Cho, Steve K; Lee, Don Haeng; Yang, Su-Geun

    2016-04-01

    In this study, we prepared macromolecular MR T1 contrast agent: pullulan-conjugated Gd diethylene triamine pentaacetate (Gd-DTPA-Pullulan) and estimated residual free Gd(3+), chelation stability in competition with metal ions, plasma and tissue pharmacokinetics, and abdominal MR contrast on rats. Residual free Gd(3+) in Gd-DTPA-Pullulan was measured using colorimetric spectroscopy. The transmetalation of Gd(3+) incubated with Ca(2+) was performed by using a dialysis membrane (MWCO 100-500 Da) and investigated by ICP-OES. The plasma concentration profiles of Gd-DTPA-Pullulan were estimated after intravenous injection at a dose 0.1 mmol/kg of Gd. The coronal-plane abdominal images of normal rats were observed by MR imaging. The content of free Gd(3+), the toxic residual form, was less than 0.01%. Chelation stability of Gd-DTPA-Pullulan was estimated, and only 0.2% and 0.00045% of Gd(3+) were released from Gd-DTPA-Pullulan after 2h incubation with Ca(2+) and Fe(2+), respectively. Gd-DTPA-Pullulan displayed the extended plasma half-life (t1/2,α=0.43 h, t1/2,β=2.32 h), much longer than 0.11h and 0.79 h of Gd-EOB-DTPA. Abdominal MR imaging showed Gd-DTPA-Pullulan maintained initial MR contrast for 30 min. The extended plasma half-life of Gd-DTPA-Pullulan probably allows the prolonged MR acquisition time in clinic with enhanced MR contrast. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Efficacy of high iodine concentration contrast medium with saline pushing in hepatic CT in patients with chronic liver disease. Comparison of high doses-standard contrast medium concentration

    International Nuclear Information System (INIS)

    Matoba, Munetaka; Kondo, Tamaki; Nishikawa, Takahiro; Kuginuki, Yasuaki; Yokota, Hajime; Higashi, Kotaro; Tonami, Hisao

    2006-01-01

    The aim of this study was to compare the enhancement of liver parenchyama with high iodine concentration contrast medium with saline pushing to that with high doses standard iodine concentration in hepatic CT in patients with chronic liver disease. There was no statistically significant difference regarding to the enhancement of liver parenchyama between the 370 mgI/ml of contrast medium with saline pushing and high doses standard iodine concentration contrast medium. (author)

  5. Local blood-brain barrier penetration following systemic contrast medium administration

    International Nuclear Information System (INIS)

    Utz, R.; Ekholm, S.E.; Isaac, L.; Sands, M.; Fonte, D.

    1988-01-01

    The present study was initiated by a severe complication in a patient with renal dysfunction who developed cortical blindness and weakness of her left extremities 30 hours following renal and abdominal angiography. To evaluate the impact of prolonged high serum concentrations of contrast medium (CM) this clinical situation was simulated in a laboratory model using sheep with elevated serum levels of contrast medium maintained for 48 hours. The experimental data did not support the theory that the prolonged exposure to high circulating levels of contrast medium (4 ml/kg body weight of meglumine diatrizoate 60%) is sufficient alone to cause penetration of the blood-brain barrier. (orig.)

  6. Enhanced conjugation stability and blood circulation time of macromolecular gadolinium-DTPA contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Jenjob, Ratchapol [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of); Kun, Na [Department of Biotechnology, The Catholic University of Korea, 43 Jibong-ro, Wonmi-gu, Bucheon-si, Gyeonggi-do 420-743 (Korea, Republic of); Ghee, Jung Yeon [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Shen, Zheyu; Wu, Xiaoxia [Division of Functional Materials and Nano-Devices, Ningbo Institute of Materials Technology & Engineering (NIMTE), Chinese Academy of Sciences, 519 Zhuangshi Street, Zhenhai District, Ningbo, Zhejiang 315201 (China); Cho, Steve K., E-mail: scho@gist.ac.kr [Division of Liberal Arts and Science, GIST College, Gwangju Institute of Science and Technology, Gwangju 500-712 (Korea, Republic of); Lee, Don Haeng [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Department of Internal Medicine, School of Medicine, Inha University Hospital, Incheon 420-751 (Korea, Republic of); Yang, Su-Geun, E-mail: Sugeun.Yang@Inha.ac.kr [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of)

    2016-04-01

    In this study, we prepared macromolecular MR T1 contrast agent: pullulan-conjugated Gd diethylene triamine pentaacetate (Gd-DTPA-Pullulan) and estimated residual free Gd{sup 3+}, chelation stability in competition with metal ions, plasma and tissue pharmacokinetics, and abdominal MR contrast on rats. Residual free Gd{sup 3+} in Gd-DTPA-Pullulan was measured using colorimetric spectroscopy. The transmetalation of Gd{sup 3+} incubated with Ca{sup 2+} was performed by using a dialysis membrane (MWCO 100–500 Da) and investigated by ICP-OES. The plasma concentration profiles of Gd-DTPA-Pullulan were estimated after intravenous injection at a dose 0.1 mmol/kg of Gd. The coronal-plane abdominal images of normal rats were observed by MR imaging. The content of free Gd{sup 3+}, the toxic residual form, was less than 0.01%. Chelation stability of Gd-DTPA-Pullulan was estimated, and only 0.2% and 0.00045% of Gd{sup 3+} were released from Gd-DTPA-Pullulan after 2 h incubation with Ca{sup 2+} and Fe{sup 2+}, respectively. Gd-DTPA-Pullulan displayed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h), much longer than 0.11 h and 0.79 h of Gd-EOB-DTPA. Abdominal MR imaging showed Gd-DTPA-Pullulan maintained initial MR contrast for 30 min. The extended plasma half-life of Gd-DTPA-Pullulan probably allows the prolonged MR acquisition time in clinic with enhanced MR contrast. - Highlights: • Macromolecule (pullulan) conjugated Gd contrast agent (Gd-DTPA-Pullulan) showed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h) in comparison with Gd-EOB-DTPA • Gd-DTPA-pullulan T1 contrast agent exhibited strong chelation stability against Gd. • The extended blood circulation attributed the enhanced and prolonged MR contrast on abdominal region of rats. • The extended blood circulation may provide prolonged MR acquisition time window in clinics.

  7. Recommendation to use iso-osmotic contrast medium in interventional treatment

    International Nuclear Information System (INIS)

    Zhou Bing; Cheng Yongde

    2012-01-01

    With the rapid development of imaging diagnostic and interventional therapeutic techniques, the contrast medium (CM) has been used more and more common in clinical practice, and meanwhile more and more attention has been paid to the CM-related adverse events. Contrast induced nephropathy (CN) is the most common CM-related adverse event, and CM-related neurotoxicity has already attracted the physicians' attention. The osmotic pressure of the iso-osmotic contrast medium (IOCM) is quite the same as that of the plasma, and therefore its safety is higher than that of low-osmotic contrast medium (LOCM), the patient's tolerance to IOCM is better than that to LOCM. For this reason, the use of IOCM should be strongly recommended in interventional procedures, which is of great significance to the reduction of the occurrence of CM-related adverse events. (authors)

  8. Radiculography with reduced amounts of contrast medium

    International Nuclear Information System (INIS)

    Signorini, E.; Caputo, N.; Chiurulla, C.; Ciorba, E.; Pelliccioli, G.P.; Cianciulli, E.

    1984-01-01

    Because of the frequency and seriousness of side effects observed after radiculography, due to, among the other things, the amount of contrast medium, the authors describe a method that gives diagnostically satisfactory results using a low dose of contrast and a tangent-beam technique. Among 106 patients undergoing radiculography with a tangent-beam technique and Iopamidol, only 4 developed mild side effects, namely headache in three cases and headache with nausea in one. (Author)

  9. Targeting cancer chemotherapeutic agents by use of lipiodol contrast medium

    International Nuclear Information System (INIS)

    Konno, T.

    1990-01-01

    Arterially administered Lipiodol Ultrafluid contrast medium selectively remained in various malignant solid tumors because of the difference in time required for the removal of Lipiodol contrast medium from normal capillaries and tumor neovasculature. Although blood flow was maintained in the tumor, even immediately after injection Lipiodol contrast medium remained in the neovasculature of the tumor. To target anti-cancer agents to tumors by using Lipiodol contrast medium as a carrier, the characteristics of the agents were examined. Anti-cancer agents had to be soluble in Lipiodol, be stable in it, and separate gradually from it so that the anti-cancer agents would selectively remain in the tumor. These conditions were found to be necessary on the basis of the measurement of radioactivity in VX2 tumors implanted in the liver of 16 rabbits that received arterial injections of 14C-labeled doxorubicin. Antitumor activities and side effects of arterial injections of two types of anti-cancer agents were compared in 76 rabbits with VX2 tumors. Oily anti-cancer agents that had characteristics essential for targeting were compared with simple mixtures of anti-cancer agents with Lipiodol contrast medium that did not have these essential characteristics. Groups of rabbits that received oily anti-cancer agents responded significantly better than groups that received simple mixtures, and side effects were observed more frequently in the groups that received the simple mixtures. These results suggest that targeting of the anti-cancer agent to the tumor is important for treatment of solid malignant tumors

  10. Contrast enhancement technique in brain 3D-CTA studies. Optimizing the amount of contrast medium according to scan time based on TDC

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi

    2008-01-01

    In three-dimensional CT angiography (3D-CTA), good reproducibility can be obtained by maintaining the maximum CT numbers (HU) at a specified level. However, the correlation between the scan time and the injection time showed that the maximum CT numbers increased and varied due to the additional contrast enhancement effect from recirculation of the injected contrast medium for longer injection times when the dose of iodinated contrast medium per unit time (mgI/s) was maintained at a specified level based on the time-density curve (TDC) of the phantom. The amount of contrast medium employed at our hospital has been optimized based on an iodinated contrast medium dose per unit time providing a contrast enhancement effect of 300 HU in the middle cerebral artery. Using this standard, a TDC phantom was employed to obtain an iodinated contrast medium dose per unit time, permitting equivalent maximum CT values (used as standard values) to be obtained by changing the injection time. A contrast-enhancement technique that accounts for the variation in the scan time was evaluated. Strong correlations were observed between the scan time and the injection time (R 2 =0.969) and between the injection time and the dose of iodinated contrast medium per unit body weight (R 2 =0.994). We conclude that adjusting the dose of iodinated contrast medium per unit body weight per unit time according to the scan time permits optimization of the contrast-enhancement technique. (author)

  11. MRI of the liver with the new contrast medium Gd-BOPTA

    International Nuclear Information System (INIS)

    Vogl, T.J.; Pegios, W.; Balzer, J.; Lissner, J.; Pirovano, G.

    1992-01-01

    A phase 1 study on 8 normals has been carried out to determine the effectiveness and safety during MRI of a new hepatobiliary contrast medium Gd-BOPTA for causing enhancement of the upper abdominal organs. Gradient echo sequences (flash), T 1 and T 2 -weighted spin echo sequences and turbo-flash sequences were used. The contrast medium was given as a single infusion in various concentrations (0.005, 0.05, 0.1 and 0.2 mmol/kg body weight). Optimal contrast of liver parenchyma was obtained with a dose of 0.05-0.1 mmol/kg body weight, resulting in contrast increase of 149.1% during gradient echo sequences and 107.8% during T 1 spin echo sequences. In general, the increased contrast lasted for about two hours. Because of the biliary and renal excretion there was an enormous increase in signal intensity of the bile ducts and a significant increase in the kidneys and ureters. The results of the first in-vivo-trial of Gd-BOPTA encourages the performance of further clinical studies of this new hepatobiliary contrast medium. (orig.) [de

  12. Computed tomography using contrast medium in disorders of the patello-femoral joint

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kenji; Chiba, Mitsuho; Morita, Hiromi; Kikuchi, Toshihiko; Shimada, Yoichi; Yamamoto, Masahiro; Tozawa, Kazuma

    1985-01-01

    The morphology and alignment of the articular cartilage of the patello-femoral joint were examined by computed tomography (CT) using a contrast medium in 15 patients with a chief complaint of patellar pain. CT was undertaken immediately after injecting a contrast medium and air into the knee joint. Retention and irregularity of the contrast medium in the joint estimated the expansion and depth of lesions in patients with osteomalacia of the auricular joint or osteoarthritis of the knee, and the thickness of the auricular cartilage. Considering the individual differences of the patella itself and specificity of the form of the auricular cartilage, the auricular joint should also be examined in terms of alignment of the cartilage surface. CT using a contrast medium is a simple, less invasive method for evaluating disorders of the patello-femoral joint.

  13. Potential mechanisms behind contrast medium-induced nephropathy

    African Journals Online (AJOL)

    How contrast medium-induced nephropathy (CIN) comes about is poorly understood, although CIN is a common cause of acute renal failure. Hitherto, the various studies performed have led to different interpretations and partially contradictory conclusions. This article aimed to review the mechanisms underlying CIN and to ...

  14. Effects of use of the lodine contrast medium on gamma camera imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pyo, Sung Jae; Cho, Yun Ho [Dept. of Nuclear Medicine, Inha University hospital, Incheon (Korea, Republic of); Choi, Jae Ho [Dept. of Radiological Technology, Ansan College, Ansan (Korea, Republic of)

    2016-12-15

    Effects of Gamma camera imaging on gamma ray counting rates as a function of use and density of the iodine contrast medium currently in primary use for clinics, and changes in gamma ray counting rates as a function of the contrast medium status upon attenuation correction using a CT absorption coefficientin an SPECT/CT attenuation correction will be considered herein. For experimental materials used 99mTcO4 370 MBq and Pamiray 370 mg, Iomeron 350 mg, Visipaque 320 mg, Bonorex 300 mg of iodine contrast medium. For image acquisition, planar imaging was consecutively filmed for 1, 2, 3, 4, 5 min, respectively, 30 min after administration of 99mTcO4. while 60 views were filmed per frame for 20 min at 55 min for the SPECT/CT imaging. In planar imaging, the gamma ray counting rates as a function of filming time were reduced showing a statistically significant difference when mixed according to the type of contrast medium density rather than when the radioactive isotope 99mTcO4 and the saline solution were mixed. In the tomography for mixing of the radioactive isotope 99mTcO4 and saline solution, the mean counting rate without correction by the CT absorption coefficient is 182±26 counts, while the counting rate with correction by the CT absorption coefficient is 531.3±34 counts. In the tomography for mixing of the radioactive isotope 99mTcO4 and the saline solution with the contrast medium, the mean values before attenuation correction by CT absorption coefficient were 166±29, 158.3±17, 154±36, and 150±33 counts depending on the densities of the contrast medium, while the mean values after attenuation correction were 515±03, 503±10, 496±31, and 488.7±33 counts, showing significant differences in both cases when comparatively evaluated with the imaging for no mixing of the contrast medium. Iodine contrast medium affects the rate of gamma ray. Therefore, You should always be preceded before another test on the day of diagnosis.

  15. Renal clearance of an ionic high-osmolar and a nonionic low-osmolar contrast medium

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Vestergaard, A.; Nielsen, S.L.; Fogh-Andersen, N.; Golman, K.; Dorph, S.

    1991-01-01

    One hundred patients with normal serum creatinine concentration underwent intravenous urography with either an ionic high-osmolar (diatrizoate) or a nonionic low-osmolar (iopamidol) contrast medium after randomization. Before injection of the contrast medium, a blood sample was drawn for determinating serum creatinine concentration, and a urine sample for measurement of urine osmolality. Using x-ray fluorescence, the plasma concentration of iodine (contrast medium) was determined on blood samples drawn approximately 3 and 4 hours after injection of the contrast medium. The glomerular filtration rate was calculated by two different formulas: one requiring only a single sample and one requiring at least two samples (standard). There were poor correlations between the standard contrast medium clearance and the serum creatinine concentration, the estimated creatinine clearance (calculated from a nomogram), as well as the urine osmolality. The 3-hour and the 4-hour single-sample values correlated well with the two-sample values for both contrast media. In patients with normal serum creatinine, the glomerular filtration rate determined by measuring the contrast medium concentration in a single plasma sample obtained at 3 hours, is almost identical to the value determined from two samples. Consequently, two samples are unnecessary

  16. Improve identification of details in double-contrast examination of the stomach by means of a new contrast medium mixture

    International Nuclear Information System (INIS)

    Tenner, R.

    1984-01-01

    In a contrast medium study, 100 patients were employed for a comparison between the contrast medium Mikropaque liquid and a mixture of Mikropaque HD and Mikropaque liquid in double-contrast examination of the stomach. The special feature of this method was that one and the same stomach was examined in each case with both contrast media. The new contrast media mixture with Mikropaque HD represents a step forward; the contrast could be enhanced in 80% of the cases, and the finely contoured relief became visible in two-thirds of the cases, compared with one-third of the examined patients before this method was introduced. (orig.) [de

  17. Adverse effects in coronary angiography: a comparative study of different temperature contrast medium

    International Nuclear Information System (INIS)

    Zhou Peng; Wang Qiulin; Cai Guocai; Li Lu; Jiang Licheng; Yang Zhen; Huang Xiuping

    2011-01-01

    Objective: To investigate the correlation between different temperature contrast medium and the occurrence of adverse effects, including the chest discomfort, the changes of heart rate, ST segment and T wave, the operating time and the used dosage of contrast medium, in performing coronary angiography. Methods: According to the contrast medium temperature used in coronary angiography, the patients were randomly divided into two groups: room temperature group (n=521) and warm temperature group (n=522). The contrast medium used in warm temperature group was bathed in 37 ℃ water for 60 minutes when the coronary angiography was carried out. The T Wave amplitude changes ≥ 0.01 mv, ST segment depression ≥ 0.05 mv, changes in heart rate ≥ 10 times/min were brought into the positive accounting. The occurrence of adverse effects, such as palpitation, chest distress and pectoralgia, the operative time and the used dosage of contrast medium were recorded. The results were analyzed and compared between the two groups. Results: Statistically significant differences in the changes of heart rate, ST segment deviation, T wave change and operating time existed between the two groups (P<0.05). And the difference in the occurrence of adverse effects between the two groups was also statistically significant (P<0.05). Conclusion: When performing coronary angiography, warming of the contrast medium with water bath is greatly conducive to the prevention of cardiac adverse effects. (authors)

  18. The affects of contrast medium on renal function in selective coronary angiography and intervention

    International Nuclear Information System (INIS)

    Chen Yueguang; Lv Baojing

    2006-01-01

    Selective coronary angiography and intervention with injection of contrast medium into the coronary arteries has become very common in dealing with coronary cardiac diseases. The excretion of contrast medium through kidneys may lead to acute renal functional insufficiency, especially for those suffering from chronic nephropathy, diabetes and cardiac functional disorder to form the so called 'contrast medium nephropathy' which is considered as the number second drug induced acute renal functional failure. Although routine preventive measure including low osmotic contrast medium and fine hydrotherapy have been taken, 14% incidences still occur with renal functional damage. The majority could be reversible but the minority needs emergent hemodialysis or even with persistent renal functional damage in a few ones. (authors)

  19. Valuation of using saline flush technique of contrast medium on abdominal multidetector row CT scanning

    International Nuclear Information System (INIS)

    Zhao Hong; Wang Ying; He Yanli; Liu Xiaobing; Bao Shiliang; Han Mingjun

    2006-01-01

    Objective: The purpose of this study was to compare the enhancement degree of abdomen organs and vessels after different amount of contrast medium using saline flush in abdomen MDCT scanning, which aimed to not affect contrast enhancement, decreased the amount of contrast medium, and reduced the side-effect. Methods: This study group consisted of 75 patients who were referred for contrast enhanced abdominal MDCT for various reasons. Patients were allocated into three groups: injection of 100ml of contrast medium only (A group), injection of 80ml pushed with 20ml of saline solution (B group), and injection of 70ml pushed with 30ml of saline solution (C group). Attenuation values were measured from the liver, spleen, pancreas, kidney, aorta, portal vein, and inferior vena cava in 33 second and 80 second of imaging after injection contrast medium. Results: The portal venous phases of the spleen, pancreas, kidney, aorta, portal vein had statistically significant difference among groups A, B and C. Post hoc test showed statistically significant difference between A group and C group, But no statistically significant difference during the portal venous phases of the pancreas and the kidney between A group and B group. Conclusion: Using a saline flush technique after the injection contrast medium in abdominal MDCT reduced waste of contrast medium and decrease in nephrotoxicity, at the same time, it would not lose important diagnostic information and saved patients cost for the contrast medium. (authors)

  20. Extravasation of contrast medium during CT examination: An ...

    African Journals Online (AJOL)

    2013-03-31

    Extravasation of contrast medium during CT examination: An observational casecontrol study. ... Methods: every incident of extravasation which occurred between March 2012 and March 31, 2013 was recorded in an extravasation form. Ethics Committee approval was obtained and the patients gave their consent to ...

  1. Quantitative contrast-enhanced mammography for contrast medium kinetics studies

    Science.gov (United States)

    Arvanitis, C. D.; Speller, R.

    2009-10-01

    Quantitative contrast-enhanced mammography, based on a dual-energy approach, aims to extract quantitative and temporal information of the tumour enhancement after administration of iodinated vascular contrast media. Simulations using analytical expressions and optimization of critical parameters essential for the development of quantitative contrast-enhanced mammography are presented. The procedure has been experimentally evaluated using a tissue-equivalent phantom and an amorphous silicon active matrix flat panel imager. The x-ray beams were produced by a tungsten target tube and spectrally shaped using readily available materials. Measurement of iodine projected thickness in mg cm-2 has been performed. The effect of beam hardening does not introduce nonlinearities in the measurement of iodine projected thickness for values of thicknesses found in clinical investigations. However, scattered radiation introduces significant deviations from slope equal to unity when compared with the actual iodine projected thickness. Scatter correction before the analysis of the dual-energy images provides accurate iodine projected thickness measurements. At 10% of the exposure used in clinical mammography, signal-to-noise ratios in excess of 5 were achieved for iodine projected thicknesses less than 3 mg cm-2 within a 4 cm thick phantom. For the extraction of temporal information, a limited number of low-dose images were used with the phantom incorporating a flow of iodinated contrast medium. The results suggest that spatial and temporal information of iodinated contrast media can be used to indirectly measure the tumour microvessel density and determine its uptake and washout from breast tumours. The proposed method can significantly improve tumour detection in dense breasts. Its application to perform in situ x-ray biopsy and assessment of the oncolytic effect of anticancer agents is foreseeable.

  2. Dual Energy CT Angiography of Peripheral Arterial Disease: Feasibility of Using Lower Contrast Medium Volume.

    Directory of Open Access Journals (Sweden)

    Abdulrahman Almutairi

    Full Text Available One of the main drawbacks associated with Dual Energy Computed Tomography Angiography (DECTA is the risk of developing contrast medium-induced nephropathy (CIN. The aim of the present study was firstly, to design an optimal CT imaging protocol by determining the feasibility of using a reduced contrast medium volume in peripheral arterial DECTA, and secondly, to compare the results with those obtained from using routine contrast medium volume.Thirty four patients underwent DECTA for the diagnosis of peripheral arterial disease. They were randomly divided into two groups: Group 1 (routine contrast volume group with n = 17, injection rate 4-5 ml/s, and 1.5 ml/kg of contrast medium, and Group 2 ((low contrast volume group, with n = 17, injection rate 4-5ml/s, and contrast medium volume 0.75 ml/kg. A fast kilovoltage-switching 64-slice CT scanner in the dual-energy mode was employed for the study. A total of 6 datasets of monochromatic images at 50, 55, 60, 65, 70 and 75 keV levels were reconstructed with adaptive statistical iterative reconstruction (ASIR at 50%. A 4-point scale was the tool for qualitative analysis of results. The two groups were compared and assessed quantitatively for image quality on the basis of signal-to-noise ratio (SNR and contrast-to-noise-ratio (CNR. Radiation and contrast medium doses were also compared.The overall mean CT attenuation and mean noise for all lower extremity body parts was significantly lower for the low volume contrast group (p<0.001, and varied significantly between groups (p = 0.001, body parts (p<0.001 and keVs (p<0.001. The interaction between group body parts was significant with CT attenuation and CNR (p = 0.002 and 0.003 respectively, and marginally significant with SNR (p = 0.047, with minimal changes noticed between the two groups. Group 2 (low contrast volume group displayed the lowest image noise between 65 and 70 keV, recorded the highest SNR and CNR at 65 keV, and produced significantly lower

  3. Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Jo, K.I.; Kim, S.R.; Choi, J.H.; Kim, K.H.; Jeon, P. [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Gangnam-gu, Seoul (Korea, Republic of)

    2015-11-15

    Contrast-enhanced cone-beam computed tomography (CBCT) has been introduced and accepted as a useful technique to evaluate delicate vascular anatomy and neurovascular stents. Current protocol for CBCT requires quantitative dilution of contrast medium to obtain adequate quality images. Here, we introduce simple methods to obtain contrast-enhanced CBCT without quantitative contrast dilution. A simple experiment was performed to estimate the change in flow rate in the internal carotid artery during the procedure. Transcranial doppler (TCD) was used to evaluate the velocity change before and after catheterization and fluid infusion. In addition, 0.3 cm{sup 3}/s (n = 3) and 0.2 cm{sup 3}/s (n = 7) contrast infusions were injected and followed by saline flushes using a 300 mmHg pressure bag to evaluate neurovascular stent and host arteries. Flow velocities changed -15 ± 6.8 % and +17 ± 5.5 % from baseline during catheterization and guiding catheter flushing with a 300 mmHg pressure bag, respectively. Evaluation of the stents and vascular structure was feasible using this technique in all patients. Quality assessment showed that the 0.2 cm{sup 3}/s contrast infusion protocol was better for evaluating the stent and host artery. Contrast-enhanced CBCT can be performed without quantitative contrast dilution. Adequate contrast dilution can be achieved with a small saline flush and normal blood flow. (orig.)

  4. Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study.

    Science.gov (United States)

    Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Royon, Laurent; Marcy, Pierre Yves; Merckx, Jacques

    2013-01-01

    The use of totally implantable venous access devices (TIVADs) certified as "high pressure resistant" or "power port" has begun to spread worldwide as a safe procedure for power contrast injection. Owing to the thermo-rheological properties of the contrast media, the primary aim of this work is to present an in vitro experimental impact study concerning the impact of the temperature level on flushing efficiency after contrast medium injection. Moreover, we report experimental data that confirms the role of needle bevel orientation. The secondary aim is to answer the following questions: Is there significant device contrast medium trapping after contrast medium injection? Is saline flushing efficient? And, finally, is it safe to inject contrast medium through an indwelled port catheter? The experimental results show that in addition to hydrodynamics, temperature is a key parameter for the efficiency of device flushing after contrast medium injection. It appears that this is the case when the cavity is incompletely rinsed after three calibrated flushing volumes of 10 mL saline solution, even by using the Huber needle bevel opposite to the port exit. This leads to a potentially important trapped volume of contrast medium in the port, and consequently to the possibility of subsequent salt precipitates and long term trisubstituted benzene nuclei delivery that might impair the solute properties, which may be further injected via the power port later on. We thus suggest, in TIVADS patients, the use of a temporary supplementary intravenous line rather than the port to perform contrast medium injections in daily radiology routine practice.

  5. Oral contrast medium in PET/CT: should you or shouldn't you?

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Dickson, John C.; Townsend, Caroline; Croasdale, Ian; Syed, Rizwan; Nagabushan, Nagesh; Hain, Sharon F.; Ell, Peter J.; Bomanji, Jamshed B.

    2005-01-01

    It has been suggested that the use of computed tomography (CT) positive contrast agents has led to attenuation-induced artefacts on 18 F-fluorodeoxyglucose positron emission tomography ( 18 F-FDG PET/CT) systems. Consequently, centres may withhold the use of such agents. Whilst there is theoretical evidence to support the aforementioned claim, the clinical relevance of the induced artefacts has not been widely established. Moreover, the potential benefits of bowel enhancement on PET/CT have yet to be formally evaluated. We therefore prospectively examined PET/CT studies to assess whether the use of oral contrast medium induces clinically relevant artefacts and whether the use of these agents is diagnostically helpful. Over a 2-month period, 18 F-FDG PET/CT images were prospectively reviewed from 200 patients following Gastrografin administration 2 h prior to examination. Both a radiologist and a nuclear medicine physician reviewed the images for contrast medium-mediated clinically relevant artefacts. Artefacts were sought on the CT attenuation-corrected images and were compared with the appearance on non-attenuated-corrected images. The number of examinations in which the oral contrast aided image interpretation was also noted. There were no oral contrast medium-induced clinically significant artefacts. In 38 of the 200 patients, oral contrast aided image interpretation (owing to differentiation of mass/node from bowel, discrimination of intestinal wall from lumen or definition of the anatomy of a relevant site). In 33 of these 38 patients, the anatomical site of interest was the abdomen/pelvis. The use of oral contrast medium in 18 F-FDG PET studies should not be withheld as it improves image interpretation and does not produce clinically significant artefacts. (orig.)

  6. Power port contrast medium flushing and trapping: impact of temperature, an in vitro experimental study

    Directory of Open Access Journals (Sweden)

    Guiffant G

    2013-09-01

    Full Text Available Gérard Guiffant,1 Jean Jacques Durussel,1 Patrice Flaud,1 Laurent Royon,1 Pierre Yves Marcy,2 Jacques Merckx1,31University Paris Diderot, Paris, France; 2Radiodiagnosis and Interventional Radiology Department, Caen, France; 3University Teaching Hospital Necker-Enfants Malades, Paris, FrancePurpose: The use of totally implantable venous access devices (TIVADs certified as "high pressure resistant" or "power port" has begun to spread worldwide as a safe procedure for power contrast injection. Owing to the thermo-rheological properties of the contrast media, the primary aim of this work is to present an in vitro experimental impact study concerning the impact of the temperature level on flushing efficiency after contrast medium injection. Moreover, we report experimental data that confirms the role of needle bevel orientation. The secondary aim is to answer the following questions: Is there significant device contrast medium trapping after contrast medium injection? Is saline flushing efficient? And, finally, is it safe to inject contrast medium through an indwelled port catheter?Results: The experimental results show that in addition to hydrodynamics, temperature is a key parameter for the efficiency of device flushing after contrast medium injection. It appears that this is the case when the cavity is incompletely rinsed after three calibrated flushing volumes of 10 mL saline solution, even by using the Huber needle bevel opposite to the port exit. This leads to a potentially important trapped volume of contrast medium in the port, and consequently to the possibility of subsequent salt precipitates and long term trisubstituted benzene nuclei delivery that might impair the solute properties, which may be further injected via the power port later on.Conclusion: We thus suggest, in TIVADS patients, the use of a temporary supplementary intravenous line rather than the port to perform contrast medium injections in daily radiology routine practice

  7. Design, synthesis, and evaluation of VEGFR-targeted macromolecular MRI contrast agent based on biotin–avidin-specific binding

    Science.gov (United States)

    Liu, Yongjun; Wu, Xiaoyun; Sun, Xiaohe; Wang, Dan; Zhong, Ying; Jiang, Dandan; Wang, Tianqi; Yu, Dexin; Zhang, Na

    2017-01-01

    Developing magnetic resonance imaging (MRI) contrast agents with high relaxivity and specificity was essential to increase MRI diagnostic sensitivity and accuracy. In this study, the MRI contrast agent, vascular endothelial growth factor receptor (VEGFR)-targeted poly (l-lysine) (PLL)-diethylene triamine pentacetate acid (DTPA)-gadolinium (Gd) (VEGFR-targeted PLL-DTPA-Gd, VPDG), was designed and prepared to enhance the MRI diagnosis capacity of tumor. Biotin-PLL-DTPA-Gd was synthesized first, then, VEGFR antibody was linked to biotin-PLL-DTPA-Gd using biotin–avidin reaction. In vitro cytotoxicity study results showed that VPDG had low toxicity to MCF-7 cells and HepG2 cells at experimental concentrations. In cell uptake experiments, VPDG could significantly increase the internalization rates (61.75%±5.22%) in VEGFR-positive HepG2 cells compared to PLL-DTPA-Gd (PDG) (25.16%±4.71%, P<0.05). In MRI studies in vitro, significantly higher T1 relaxivity (14.184 mM−1 s−1) was observed compared to Magnevist® (4.9 mM−1 s−1; P<0.01). Furthermore, in vivo MRI study results showed that VPDG could significantly enhance the tumor signal intensity and prolong the diagnostic time (from <1 h to 2.5 h). These results indicated that macromolecular VPDG was a promising MRI contrast agent and held great potential for molecular diagnosis of tumor. PMID:28765707

  8. Contrast-medium-induced nephropathy: is there a new consensus? A review of published guidelines

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.; Morcos, Sameh K.

    2006-01-01

    The interest in contrast-medium-induced nephropathy has increased considerably during the last few years. Various guidelines regarding identifying patients at risk and measures to reduce the incidence of this complication have been proposed. The aim of this review was to analyse whether there is some consistency amongst these guidelines. A Medline search for the keyword ''contrast medium induced nephropathy'' during the period from the beginning of 2003 through the end of September 2005 was carried out. Only papers in English were reviewed. Thirteen guidelines were identified. Inconsistency was observed regarding advise on the prophylactic use of drugs and the isoosmolar dimer to reduce the incidence of contrast-medium-induced nephropathy. Consistency was found in relation to the importance of hydration, cessation of intake of nephrotoxic drugs and administration of the lowest possible dose of contrast medium. No new consensus has been observed in comparison to the European Society for Urogenital Radiology (ESUR) guidelines, which were published in 1999. (orig.)

  9. Use of iohexol as a gastrointestinal contrast medium in the dog

    International Nuclear Information System (INIS)

    Agut, A.; Sanchez-Valverde, M.A.; Lasaosa, J.M.; Murciano, J.; Molina, F.

    1993-01-01

    Iohexol was administered orally in five dogs. The dose, gastrointestinal (GI) transit time, appearance of mucosal patterns and side effects were studied. Three different doses (525, 700, 875 mgI/kg) were used in each dog at 1-week intervals. GI transit time was rapid. In each dose, gastric emptying commenced immediately after administration of the contrast medium, and was completed within 30–60 min with doses of 525–700 mgI/kg and 90–120 min with 875 mgI/kg. Large intestinal filling was observed within 60-90 min. In the majority of studies, the mucosal border appeared as a thin homogeneous halo of lucency surrounding the more opaque bowel lumen contents. The contrast intensity was not adequate with the lowest dose. The image quality did not deteriorate along the GI tract. No adverse reactions were found. Iohexol is an alternative GI contrast medium in the dog when contrast media are contraindicated

  10. Nitrogen isotopic composition of macromolecular organic matter in interplanetary dust particles

    Science.gov (United States)

    Aléon, Jérôme; Robert, François; Chaussidon, Marc; Marty, Bernard

    2003-10-01

    Nitrogen concentrations and isotopic compositions were measured by ion microprobe scanning imaging in two interplanetary dust particles L2021 K1 and L2036 E22, in which imaging of D/H and C/H ratios has previously evidenced the presence of D-rich macromolecular organic components. High nitrogen concentrations of 10-20 wt% and δ 15N values up to +400‰ are observed in these D-rich macromolecular components. The previous study of D/H and C/H ratios has revealed three different D-rich macromolecular phases. The one previously ascribed to macromolecular organic matter akin the insoluble organic matter (IOM) from carbonaceous chondrites is enriched in nitrogen by one order of magnitude compared to the carbonaceous chondrite IOM, although its isotopic composition is still similar to what is known from Renazzo (δ 15N = +208‰). The correlation observed in macromolecular organic material between the D- and 15N-excesses suggests that the latter originate probably from chemical reactions typical of the cold interstellar medium. These interstellar materials preserved to some extent in IDPs are therefore macromolecular organic components with various aliphaticity and aromaticity. They are heavily N-heterosubstituted as shown by their high nitrogen concentrations >10 wt%. They have high D/H ratios >10 -3 and δ 15N values ≥ +400‰. In L2021 K1 a mixture is observed at the micron scale between interstellar and chondritic-like organic phases. This indicates that some IDPs contain organic materials processed at various heliocentric distances in a turbulent nebula. Comparison with observation in comets suggests that these molecules may be cometary macromolecules. A correlation is observed between the D/H ratios and δ 15N values of macromolecular organic matter from IDPs, meteorites, the Earth and of major nebular reservoirs. This suggests that most macromolecular organic matter in the inner solar system was probably issued from interstellar precursors and further processed

  11. Gadolinium-DTPA and gadodiamide as an alternative contrast medium for CT

    International Nuclear Information System (INIS)

    Engelbrecht, V.; Koch, J.A.; Rassek, M.; Moedder, U.

    1996-01-01

    To evaluate the effect of intravenously applied gadolinium-based contrast medium in computed tomographic (CT) studies. Serial dilutions of iohexol 300, Gd-DTPA and gadodiamide were scanned with CT in a phantom study using water filled tubes. For quantification of X-ray attenuation, the mean Hounsfield units (HU) were calculated from the CT scans. Five patients with contraindications against iodine contrast agents were examined with abdominal or thoracic CT before and after application of 0.2 mmol/kg body weight of a gadolinium-based contrast agent. In these patients attenuation values were obtained in ROI from unenhanced and enhanced CT scans. The phantom study revealed a 38,4% enhancement for Gd-DTPA and a 35.7% enhancement for gadodiamide scaled on the reference measurements with iohexol 300. Thus, 130.2 ml Gd-DTPA or 140.1 ml gadodiamide are needed to achieve the same attenuation as an i.v. injection of 50 ml iohexol 300. Consequently the corresponding dose of 1 mmol/kg body weight would exceed the manufacturer's recommended dose. In four patients with complete thoracic or abdominal CT, i.v. applied gadolinium-based contrast medium (0.2 mmol/kg) yielded no visible advantage. In these patients parenchymal enhancement did not exceed 25%. Dynamic CT of a patient with focal liver lesion revealed an arterial enhancement peak of 75%. Sufficient parenchymal enhancement in CT studies cannot be achieved with the available gadolinium-based contrast mediums. They might be helpful if only short time vascular enhancement is required. (orig.) [de

  12. CT contrasting theory. Effects of the concentration, volume and infusion rate of iodine contrast medium on TDC

    International Nuclear Information System (INIS)

    Yamachi, Jun

    2007-01-01

    This study was performed to evaluate the effects in the title on TDC (time-density curve) using a phantom. CT machine used was Toshiba Aquilion Multi 64, TDC phantom was the product of Nemoto-Kyorindo Co., and the contrast medium was Eisai iomeprol, in syringe-sealed formulations of 300 and 350 mg I/mL. The medium was infused at 1-5 mL/sec in the phantom equivalent to body weight of 78 kg (total water volume=1 min circulation=6,000 mL, 800 mL/heart) to obtain 30 TDCs. Evaluated were the relationships of the infusion rate (mL/sec), volume (mL) or time (sec) with TDC parameters of the detection time of the medium, slope, time to reach the maximum CT value, the maximum CT value, time to keep the CT concentration and its actual concentration. Results revealed that, regardless to the difference of formulations of the contrast medium, TDC with high reproducibility can be obtainable by making the infusion rate of I per unit time and body weight (mgI/sec/kg) constant when the infusion time is made identical for CT of the same diagnostic purpose. (R.T.)

  13. Craniopharyngiomas - the utility of contrast medium enhancement for MR imaging at 1.5 T

    International Nuclear Information System (INIS)

    Hald, J.K.; Eldevik, O.P.; Brunberg, J.A.; Chandler, W.F.

    1994-01-01

    To evaluate the efficacy of i.v. contrast medium administration in MR imaging at 1.5 T in patients with craniopharyngiomas, MR studies of 10 men and 6 women with pathologically proven craniopharyngiomas were made. The MR images were obtained as 3- to 5-mm-thick coronal (n=13) or axial (n=3) T1-weighted images (T1WI) prior to an following i.v. Gd-DTPA administration. Proton density-(PD) and T2-weighted images (T2WI) were also obtained. Conspicuity of tumor margins, cystic versus solid components, size, location and effect upon adjacent structures were separately characterized in all imaging sequences. In 6 patients contrast medium-enhanced T1WI, PD and T2WI demonstrated cystic tumor components not seen on unenhanced T1WI. There were significant differences (p<0.004) on 2-tailed Student's t-test comparing tumor conspicuity on contrast medium-enhanced T1WI with unenhanced T1WI, PD and T2WI. Optimal tumor delineation on MR imaging of patients with craniopharyngiomas justifies the use of i.v. contrast medium. (orig.)

  14. Analytical model for macromolecular partitioning during yeast cell division

    International Nuclear Information System (INIS)

    Kinkhabwala, Ali; Khmelinskii, Anton; Knop, Michael

    2014-01-01

    Asymmetric cell division, whereby a parent cell generates two sibling cells with unequal content and thereby distinct fates, is central to cell differentiation, organism development and ageing. Unequal partitioning of the macromolecular content of the parent cell — which includes proteins, DNA, RNA, large proteinaceous assemblies and organelles — can be achieved by both passive (e.g. diffusion, localized retention sites) and active (e.g. motor-driven transport) processes operating in the presence of external polarity cues, internal asymmetries, spontaneous symmetry breaking, or stochastic effects. However, the quantitative contribution of different processes to the partitioning of macromolecular content is difficult to evaluate. Here we developed an analytical model that allows rapid quantitative assessment of partitioning as a function of various parameters in the budding yeast Saccharomyces cerevisiae. This model exposes quantitative degeneracies among the physical parameters that govern macromolecular partitioning, and reveals regions of the solution space where diffusion is sufficient to drive asymmetric partitioning and regions where asymmetric partitioning can only be achieved through additional processes such as motor-driven transport. Application of the model to different macromolecular assemblies suggests that partitioning of protein aggregates and episomes, but not prions, is diffusion-limited in yeast, consistent with previous reports. In contrast to computationally intensive stochastic simulations of particular scenarios, our analytical model provides an efficient and comprehensive overview of partitioning as a function of global and macromolecule-specific parameters. Identification of quantitative degeneracies among these parameters highlights the importance of their careful measurement for a given macromolecular species in order to understand the dominant processes responsible for its observed partitioning

  15. A method to evaluate the dose increase in CT with iodinated contrast medium

    International Nuclear Information System (INIS)

    Amato, Ernesto; Lizio, Domenico; Settineri, Nicola; Di Pasquale, Andrea; Salamone, Ignazio; Pandolfo, Ignazio

    2010-01-01

    Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical protocols

  16. A method to evaluate the dose increase in CT with iodinated contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Amato, Ernesto; Lizio, Domenico; Settineri, Nicola; Di Pasquale, Andrea; Salamone, Ignazio; Pandolfo, Ignazio [Department of Radiological Sciences, University of Messina, Messina 98125 (Italy); Department of Physics, University of Messina, Messina 98166 (Italy); University Hospital ' ' G. Martino' ' , Messina 98125 (Italy); Department of Radiological Sciences, University of Messina, Messina 98125 (Italy) and University Hospital ' ' G. Martino' ' , Messina 98125 (Italy)

    2010-08-15

    Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical

  17. Intravenous contrast medium application in elderly patients - evaluation of Iopentol (Imagopaque trademark 300)

    International Nuclear Information System (INIS)

    Rathsmann, P.; Jacobs, G.F.; Mueller, R.D.

    2004-01-01

    Purpose: We examined the subjective compatibility of elderly patients who received the intravenous contrast medium Iopentol (Imagopaque trademark 300). In addition, objective data were acquired to show possible interactions between contrast media and organ systems in old patients. Methods and materials: A CT scan with intravenous application of contrast media was performed on 132 patients ranging in age from 75 to 96 years. The patients were questioned about their individual sensations. In addition, blood pressure, creatinine and CT-densitometry were acquired as objective date. Results: The patients' individual sensations and clinical data show a very low rate of complications. Mild allergic reactions were noticed in two patients. No severe anaphylactic reactions were encountered. Statistically significant changes in blood pressure before and after administration of the contrast medium were not observed. The serum creatinine concentration was unchanged after application of contrast media. For CT-densitometry, the patients were divided into two groups, one group with patients 75-84 years and the other group with patients 85-96 years of age. CT-densitometry showed no age-related differences. The protocol of contrast administration resulted in excellent opacification of the examined regions, only the liver did not enhance in some cases before the opacification of the portal vein. Conclusion: It is shown that old age alone is no reason to withhold contrast media containing iodine when performing CT. For the evaluation of the liver, however, the peculiarities of old age have to be taken into account and the interval between injection of the contrast medium and beginning of the spiral-CT has to be extended. (orig.)

  18. Soft-tissue tumor differentiation using 3D power Doppler ultrasonography with echo-contrast medium injection.

    Science.gov (United States)

    Chiou, Hong-Jen; Chou, Yi-Hong; Chen, Wei-Ming; Chen, Winby; Wang, Hsin-Kai; Chang, Cheng-Yen

    2010-12-01

    We aimed to evaluate the ability of 3-dimensional power Doppler ultrasonography to differentiate soft-tissue masses from blood flow and vascularization with contrast medium. Twenty-five patients (mean age, 44.1 years; range, 12-77 years) with a palpable mass were enrolled in this study. Volume data were acquired using linear and convex 3-dimensional probes and contrast medium injected manually by bolus. Data were stored and traced slice by slice for 12 slices. All patients were scanned by the same senior sonologist. The vascular index (VI), flow index (FI), and vascular-flow index (VFI) were automatically calculated after the tumor was completely traced. All tumors were later confirmed by pathology. The study included 8 benign (mean, 36.5 mL; range, 2.4-124 mL) and 17 malignant (mean, 319.4 mL; range, 9.9-1,179.6 mL) tumors. Before contrast medium injection, mean VI, FI and VFI were, respectively, 3.22, 32.26 and 1.07 in benign tumors, and 1.97, 29.33 and 0.67 in malignant tumors. After contrast medium injection, they were, respectively, 20.85, 37.33 and 8.52 in benign tumors, and 40.12, 41.21 and 17.77 in malignant tumors. The mean differences between with and without contrast injection for VI, FI and VFI were, respectively, 17.63, 5.07 and 7.45 in benign tumors, and 38.15, 11.88 and 16.55 in malignant tumors. Tumor volume, VI, FI and VFI were not significantly different between benign and malignant tumors before and after echo-contrast medium injection. However, VI, FI and VFI under self-differentiation (differences between with and without contrast injection) were significantly different between malignant and benign tumors. Three-dimensional power Doppler ultrasound is a valuable tool for differential diagnosis of soft-tissue tumors, especially with the injection of an echo-contrast medium. Copyright © 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

  19. Optical tracking of contrast medium bolus to optimize bolus shape and timing in dynamic computed tomography

    International Nuclear Information System (INIS)

    Eisa, Fabian; Brauweiler, Robert; Peetz, Alexander; Hupfer, Martin; Nowak, Tristan; Kalender, Willi A

    2012-01-01

    One of the biggest challenges in dynamic contrast-enhanced CT is the optimal synchronization of scan start and duration with contrast medium administration in order to optimize image contrast and to reduce the amount of contrast medium. We present a new optically based approach, which was developed to investigate and optimize bolus timing and shape. The time-concentration curve of an intravenously injected test bolus of a dye is measured in peripheral vessels with an optical sensor prior to the diagnostic CT scan. The curves can be used to assess bolus shapes as a function of injection protocols and to determine contrast medium arrival times. Preliminary results for phantom and animal experiments showed the expected linear behavior between dye concentration and absorption. The kinetics of the dye was compared to iodinated contrast medium and was found to be in good agreement. The contrast enhancement curves were reliably detected in three mice with individual bolus shapes and delay times of 2.1, 3.5 and 6.1 s, respectively. The optical sensor appears to be a promising approach to optimize injection protocols and contrast enhancement timing and is applicable to all modalities without implying any additional radiation dose. Clinical tests are still necessary. (note)

  20. Utility of gadolinium as a contrast medium in endovascular therapeutic procedures; Utilidad del gadolinio como medio de contraste en procedimientos terapeuticos endovasculares

    Energy Technology Data Exchange (ETDEWEB)

    Reyes, R.; Pardo, M. D.; Gorriz, E.; Gallardo, L. (Hospital de Gran Canaria Dr. Negrin); Carreira, J. M. (Universidad de Santiago de Compostela)

    2001-07-01

    To assess the utility of gadolinium associated with CO{sub 2}, as a contrast medium in angiographic studies related to endovascular therapeutic procedures in patients with suboptimal renal function. Between January 2000 and June 2001, endovascular treatments using CO{sub 2} and gadolinium as contrast medium were performed in 10 patients presenting renal function deterioration (creatinine>1.5 mg/ml). A mean dose of 42 ml of gadolinium was administered. The images acquired in diagnostic and therapeutic studied were satisfactory in every case. There was no evidence of significant increases in the previous urea and creatine levels when measured 24, 48 and 72 hours after the procedure. In combination with CO{sub 2} gadolinium is a useful contrast medium for endovascular therapeutic procedures in patients with suboptimal renal function. (Author) 21 refs.

  1. Design, synthesis, and evaluation of VEGFR-targeted macromolecular MRI contrast agent based on biotin–avidin-specific binding

    Directory of Open Access Journals (Sweden)

    Liu YJ

    2017-07-01

    Full Text Available Yongjun Liu,1 Xiaoyun Wu,1 Xiaohe Sun,1 Dan Wang,1 Ying Zhong,1 Dandan Jiang,1 Tianqi Wang,1 Dexin Yu,2 Na Zhang1 1School of Pharmaceutical Science, Shandong University, 2Department of Radiology Medicine, Qilu Hospital, Jinan, People’s Republic of China Abstract: Developing magnetic resonance imaging (MRI contrast agents with high relaxivity and specificity was essential to increase MRI diagnostic sensitivity and accuracy. In this study, the MRI contrast agent, vascular endothelial growth factor receptor (VEGFR-targeted poly (l-lysine (PLL-diethylene triamine pentacetate acid (DTPA-gadolinium (Gd (VEGFR-targeted PLL-DTPA-Gd, VPDG, was designed and prepared to enhance the MRI diagnosis capacity of tumor. Biotin-PLL-DTPA-Gd was synthesized first, then, VEGFR antibody was linked to biotin-PLL-DTPA-Gd using biotin–avidin reaction. In vitro cytotoxicity study results showed that VPDG had low toxicity to MCF-7 cells and HepG2 cells at experimental concentrations. In cell uptake experiments, VPDG could significantly increase the internalization rates (61.75%±5.22% in VEGFR-positive HepG2 cells compared to PLL-DTPA-Gd (PDG (25.16%±4.71%, P<0.05. In MRI studies in vitro, significantly higher T1 relaxivity (14.184 mM-1 s-1 was observed compared to Magnevist® (4.9 mM-1 s-1; P<0.01. Furthermore, in vivo MRI study results showed that VPDG could significantly enhance the tumor signal intensity and prolong the diagnostic time (from <1 h to 2.5 h. These results indicated that macromolecular VPDG was a promising MRI contrast agent and held great potential for molecular diagnosis of tumor. Keywords: MRI, contrast agent, VEGFR, biotin–avidin reaction, relaxivity

  2. Aspiration of barium contrast medium in an elderly man with disordered swallowing

    OpenAIRE

    Bağcı Ceyhan, B.; Çelikel, T.; Koç, M.; Ahıskalı, R.; Biren, T.; Ataizi Çelikel, Ç.

    1995-01-01

    The aspiration of contrast medium during the investigation of gastrointestinal diseases is a well recognized hazard, particularly in patients with swallowing disorders. A case is reported in which accidental aspiration of contrast barium occurred owing to disordered swallowing in an elderly man. The infiltration on chest x-ray persisted 2 years after barium contrast aspiration. Inflammatory reaction and retractile, granular material observed in lung biopsy specimens suggested barium-induced p...

  3. Macromolecular therapeutics.

    Science.gov (United States)

    Yang, Jiyuan; Kopeček, Jindřich

    2014-09-28

    This review covers water-soluble polymer-drug conjugates and macromolecules that possess biological activity without attached low molecular weight drugs. The main design principles of traditional and backbone degradable polymer-drug conjugates as well as the development of a new paradigm in nanomedicines - (low molecular weight) drug-free macromolecular therapeutics are discussed. To address the biological features of cancer, macromolecular therapeutics directed to stem/progenitor cells and the tumor microenvironment are deliberated. Finally, the future perspectives of the field are briefly debated. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Extravasation of contrast medium into the gastrointestinal tract following lymphangiography

    International Nuclear Information System (INIS)

    Mihara, K.; Koga, K.; Tsurudome, H.; Nakano, T.; Hoshi, H.; Yamada, H.; Kawahira, K.; Inakura, M.; Watanabe, K.; Haraguchi, Y.

    1981-01-01

    Two cases with roentgenologic findings of extravasation of contrast medium into the stomach and colon following lymphangiography are presented. One is clinically diagnosed as primary intestinal lymphangiectasia; the other as retroperitoneal spread from uterine cancer. The significance of lymphangiography in gastrointestinal or retroperitoneal disorders is discussed. (orig.)

  5. Extravasation of contrast medium into the gastrointestinal tract following lymphangiography

    Energy Technology Data Exchange (ETDEWEB)

    Mihara, K.; Koga, K.; Tsurudome, H.; Nakano, T.; Hoshi, H.; Yamada, H.; Kawahira, K.; Inakura, M.; Watanabe, K.; Haraguchi, Y.

    1981-07-15

    Two cases with roentgenologic findings of extravasation of contrast medium into the stomach and colon following lymphangiography are presented. One is clinically diagnosed as primary intestinal lymphangiectasia; the other as retroperitoneal spread from uterine cancer. The significance of lymphangiography in gastrointestinal or retroperitoneal disorders is discussed.

  6. Magnetic resonance tomography of the orbit: First experiences with the paramagnetic contrast medium gadolinium-DTPA

    International Nuclear Information System (INIS)

    Markl, A.; Vogl, T.; Scheidhauer, K.; Riedel, K.G.; Oeckler, R.

    1986-01-01

    In 21 patients with orbital mass lesions MRI was performed before and after administration of paramagnetic contrast medium, gadolinium-DPTA. In comparison to the plain scan the differentiation of the tumorous tissue against the surrounding structures was improved after application of contrast medium despite a partially moderate increase in signal intensity. Especially highly vascular tumors and vessel diseases show a significant contrast enhancement. With increasing experience in larger number of patients a tissue differentiation seems to be possible. (orig.) [de

  7. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is an x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  8. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is a x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  9. Radiologic diagnosis of gastro-oesophageal reflux. Comparison of barium and low-density contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, S.G.; Soekjer, H.; Johansson, K.E.; Tibbling, L.

    It has been proposed that the high density of ordinary barium suspension may complicate the radiologic diagnosis of gastro-oesophageal reflux. For this reason P-contrast was developed (Ferring AB); a contrast medium with the same density as water (1 g/cm/sup 3/). A comparison of P-contrast and barium (Mixobar Ventrikel 400 mg/ml) was performed in 82 patients. All patients were examined with both contrast media and the findings were compared with those at reflux test at manometry, endoscopy and 24-hour pH monitoring. Another 40 patients and 15 symptom-free controls were examined with two different amounts of barium, 100 ml and 200 ml, to study if the radiologic diagnosis of reflux varied with the volume of contrast medium administered. P-contrast was found to have no advantages over barium for the diagnosis of gastro-oesophageal reflux. The outcome of the radiologic examination was not influenced by the different volumes of barium used.

  10. Gadolinium-DTPA (Magnevist) as a contrast medium for arterial DSA

    International Nuclear Information System (INIS)

    Schild, H.H.; Weber, W.; Boeck, E.; Mildenberger, P.; Strunk, H.; Dueber, C.; Grebe, P.; Schadmand-Fischer, S.; Thelen, M.

    1994-01-01

    16 DSA investigations using intra-arterial Gd-DTPA were performed on 12 patients. The contrast medium was administered either as a 0.5 molar gadolinium solution (commercially available) or diluted with distilled water to a 0.2 -0.4 molar gadolinium solution. The injection was made either by pressure injector or by hand. The aortic arch, abdominal aorta and pelvic and lower limb arteries were examined. 14 of the 16 procedures were diagnostically adequate, but compared with iodinated contrast materials, contrast was less marked. There were no cardiovascular, neurological or allergic side effects. Three patients suffered a feeling of heat and one patient had mild pain during the injection. Even large volumes rapidly injected (up to 20 ml/s of the commercially available solution) were well tolerated. DSA with intra-arterial Gd-DTPA seems to be a suitable alternative for vascular imaging if iodine-containing contrast materials are contraindicated. (orig.) [de

  11. Human pharmacokinetics of iohexol. A new nonionic contrast medium

    International Nuclear Information System (INIS)

    Olsson, B.; Aulie, A.; Sveen, K.; Andrew, E.

    1983-01-01

    The pharmacokinetics of iohexol, a new nonionic, water-soluble contrast medium, have been determined after intravenous injection in 20 healthy volunteers, at four different dose levels (125-500 mg I/kg). The apparent volume of distribution was 0.27 1/kg, indicating distribution in the extracellular water. The biologic half-life was 121 minutes, comparable with that of other intravascular contrast media. Iohexol was excreted completely unmetabolized in the urine, with a 100% recovery 24 hours after injection. A comparison of iohexol and chromium-51 ( 51 Cr)-EDTA clearances indicates that iohexol is mainly excreted by glomerular filtration. The 51 Cr-EDTA clearance was the same when injected separately and concomitantly with iohexol, indicating that glomerular filtration rate is not affected by iohexol. No dose dependency was observed in the investigated parameters t1/2 alpha, t1/2 beta, Vd, ClT or ClR. Iohexol pharmacokinetics are in correspondence with previously reported data on intravascular contrast media

  12. Diagnostic capabilities of the contrast medium verografin in liposomes (animal experiments)

    International Nuclear Information System (INIS)

    Rozenberg, O.A.; Khason, K.P.; Aliyakparov, M.T.; Davidenkova, E.F.; Zherbin, E.A.; Akademiya Meditsinskikh Nauk SSSR, Leningrad. Inst. Ehksperimental'noj Meditsiny)

    1985-01-01

    Some examples for the diagnosis of various diseases of liver and spleen after intravenous (cats, dogs) or intraportal (rodents) injection of lecithin-cholesterol liposomes containing the water soluble contrast medium verografin are described. Tumors of 1 mm were found in the spleen of mice with lymphogranulomatosis, hepatomas of 3-5 mm in rats and lesions of 10 mm in cats with turpentine abscesses. The application of liposomes containing radiographic contrast media offers good possibilities for the diagnosis of liver and spleen. (author)

  13. Computed tomography of the cervical spine with iv injection of contrast medium

    International Nuclear Information System (INIS)

    Magnaldi, S.; Pozzi-Mucelli, R.S.; Cova, M.A.; De Morpurgo, P.

    1989-01-01

    Computed Tomography (CT) without contrast medium is largely applied to the study of intervertebral disk pathology in the lumbar spine, but has not been widely accepted in cervical spine, due to technical and anatomical limitations. For these reasons many neuroradiologists still prefer myelography or myelo-CT. CT may yield better results if combined with iv contrast medium injection, which allows a better visualization of disk herniation. This technique is aimed at enhancing the density of the venous plexus which is located close to the intervertebral disk the vertebral bodies and the neural foramina. A better contrast enhancement is thus obtained between the disk and the spinal cord. The authors' experience is based on 61 patients who underwent contrast enhanced CT; in 22 cases myelography and myelo-CT were also performed. The authors describe their technique and the most frequent CT findings of disk hernation: the typical finding includes a focal hypodensity surrounded by a linear blush, due to a posteriorly dislocated epidural vein. The posterior linear blush alone may be present in few cases. Contrast enhanced CT is very useful in the study of disk pathology of the cervical spine, even when compared with myelography and myelo-CT, due the increase in the density of epidural plexus it allows. However, the technique must be very accurate if the same results as those of myelo-CT are to be obtained

  14. The association between use of metformin and change in serum CO_2 level after administration of contrast medium

    International Nuclear Information System (INIS)

    Kim, S.K.; Jung, J.; Jung, J.H.; Kim, K.Y.; Baek, J.-H.; Hahm, J.R.

    2016-01-01

    Aim: To evaluate the changes in serum creatinine and total CO_2 levels in patients receiving metformin during administration of contrast medium. Materials and methods: Patient records from January 2012 to December 2012 after the administration of contrast medium were reviewed retrospectively. A total of 924 patients were included for the final analysis. Of them, 105 received metformin during contrast medium administration, 112 were taking other oral hypoglycaemic agents, and 707 patients were not diabetic (controls). Results: No significant change in total CO_2 levels was detected (p=0.678). Metabolic acidosis was present in 33 (31.4%) metformin users, 31 (28.6%) other oral hypoglycaemic agent users, and 153 (21.6%) control patients. In the present logistic regression analysis, age, baseline levels of creatinine, and total CO_2 levels were associated with metabolic acidosis after contrast medium exposure. Conclusion: These data indicate the presence of a coexisting risk factor, other than metformin use, associated with metabolic acidosis after contrast medium exposure. No relationship was found between the use of metformin and metabolic acidosis during contrast medium exposure. - Highlights: • The use of metformin was not associated with metabolic acidosis after contrast exposure. • The coexisting risk factors for metabolic acidosis were present in patient with metabolic acidosis after contrast exposure. • There is a need to consider the maintenance of metformin during a CT scan in patients with a low risk for lactic acidosis.

  15. GE-145, a new low-osmolar dimeric radiographic contrast medium

    International Nuclear Information System (INIS)

    Wistrand, Lars-G.; Rogstad, Astri; Hagelin, Gunnar

    2010-01-01

    Background: Contrast-induced nephrotoxicity is a significant risk when using radiographic contrast media clinically, especially in high risk patients. Consequently, there is a need for a new contrast agent with improved clinical safety with regards to nephrotoxicity. Purpose: To evaluate the physicochemical properties as well as the preclinical safety and biodistribution parameters of the newly developed radiographic contrast medium GE-145. Material and Methods: Standard methods for radiographic contrast media were used for evaluation of physicochemical properties. The acute toxicity in rats was studied at 8, 10, and 12.5 gI/kg, the clinical chemistry parameters were determined, and histology of the kidneys was performed. Biodistribution was studied in rats using 123 I-labeled GE-145. Results: GE-145 is more hydrophilic than iodixanol and has a considerably lower osmolality. The viscosity is similar to that of iodixanol and the protein binding is low. The acute toxicity is similar to that of iodixanol and the biodistribution is similar to that of other radiographic contrast media, showing mainly renal excretion. Kidney histology showed a moderate reversible vacuolization, similar to that of iodixanol. Conclusion: GE-145 exhibits similar preclinical properties to other dimeric radiographic contrast media. In addition, the low osmolality enables an iso-osmolar formulation containing a significantly higher concentration of electrolytes than Visipaque

  16. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    International Nuclear Information System (INIS)

    Hausegger, K.; Reinprecht, P.; Kau, T.; Igerc, I.; Lind, P.

    2005-01-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk registered , which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk registered can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  17. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, K.; Reinprecht, P. [Roentgendiagnostisches Zentralinstitut, LKH Klagenfurt (Austria); Kau, T. [Roentgendiagnostisches Zentral Inst., Klagenfurt (Austria); Igerc, I.; Lind, P. [Abt. fuer Nuklearmedizin und Spezielle Endokrinologie, LKH Klagenfurt (Austria)

    2005-06-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk {sup registered}, which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk {sup registered} can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  18. Water as a contrast medium: a re-evaluation using the multidetector-row computed tomography.

    Science.gov (United States)

    Makarawo, Tafadzwa P; Negussie, Edsa; Malde, Sachit; Tilak, Jacqueline; Gayagoy, Jennifer; Watson, Jenna; Francis, Faiz; Lincoln, Denis; Jacobs, Michael J

    2013-07-01

    Water as an intraluminal negative contrast medium produces improved image quality with reduced artefact. However, rapid absorption of oral water in the bowel relative to speed and timing of image capturing has limited its clinical application. These findings predate advances in multidetector-row computed tomography (CT). To re-evaluate differences in image quality, we studied image clarity and luminal distention between the same group of patients who received both a pancreas protocol CT (PPCT) that uses oral water and a conventional positive oral contrast scan. We reviewed 66 patients who had previously undergone both a PPCT and an oral contrast abdominal CT. CT images were independently reviewed by two board-certified radiologists who scored degree of hollow viscus distention and visualization of mural detail using a Likert 5-point scale. Results were evaluated by using the Wilcoxon-signed rank test. Student's t test was applied to evaluate the differences in radiation dosage and Spearman's correlational test was used to evaluate interrater correlation between the radiologists. In comparing the mean radiation dosage, there was no statistical difference between the two protocols, and there was good interrater association with ratios of 0.595 and 0.51 achieved for the PPCT and conventional oral scan, respectively. The Wilcoxon signed-rank test showed statistical differences in the stomach (P contrast medium causing better or equal distention in the bowel and better or equal clarity than routine barium contrast. This calls for a need to reconsider the use of water as a contrast medium in clinical practice.

  19. Pure and diluted contrast medium in the evaluation of portal venous system with digital subtraction angiography

    International Nuclear Information System (INIS)

    Gattoni, F.; Baldini, V.; Pozzato, C.; Nessi, R.; Raiteri, R.; Uscenghi, C.; Opocher, E.; Santambrogio, R.

    1990-01-01

    We report the results of intra-arterial digital subtraction angiography (DSA) in 100 patients with portal hypertension. The portal venous system was evaluated; all patients underwent angiography of the celiac and superior mesenteric arteries before surgery. Forty-four of them were also examined after Warren splenorenal shunts. Therefore, a total of 144 exams was evaluated. The authors always employed low-osmolality ionic and non-ionic contrast media (iodine concentration: 300-350 mg/ml). In 70 cases pure contrast medium was injected (20/25 ml): in the extant 74 cases it was diluted with an equal volume of saline solution (osmolality and iodine concentration reduced by 50%). Intra-arterial DSA always visualized portal venous system, collateral circulation, shunt location and postoperative changes. The mayor advantage of intra-arterial DSA is the smaller amount of contrast medium injected, so that local and systemic side effects are rare. According to our experience, it is best to dilute the contrast medium and inject the same amount as in conventional angiography, at the same rate. Other well-known advantages of intra-arterial DSA are quicker execution, less injury to arteries using smaller caliber catheters, and low cost. The major disadvantage of intra-arterial DSA, as it appeared also in our study, is the field size of the intensifier, which in our case was limited to 6-9 inches. This is an insufficient coverage for the whole portal system to be studied, and some contrast medium injections become therefore necessary. An average of 3 injections were given to each patient. This problem reduces the advantage of less contrast medium per injection. At any rate, even though intra-arterial DSA exhibits this limitation, it can nevertheless yield important information in the pre- and postoperative evaluation of patients with portal hypertension

  20. Analysis on the entrance surface dose and contrast medium dose at computed tomography and angiography in cardiovascular examination

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Hyun [Dept. of Cardiovascular Center, Yeocheon Jeonnam Hospital, Yeosu (Korea, Republic of); Han, Jae Bok; Choi, Nam Gil; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of)

    2016-12-15

    This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48-85 years old (mean 65±10 years old), and the weight was 37.6~83.3 kg (mean 63±6 kg). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.

  1. Transient partial amnesia complicating cardiac and peripheral arteriography with nonionic contrast medium

    International Nuclear Information System (INIS)

    Yildiz, A.; Yencilek, E.; Apaydin, F.D.; Duce, M.N.; Oezer, C.; Atalay, A.

    2003-01-01

    The aim of this study was to present a case of disruption of the blood-brain barrier during the coronary and lower extremity angiographies with radiological and clinical findings. This condition was secondary to intraarterial use of a nonionic, monomeric contrast medium. A total of 450 cc contrast media was used. Computed tomography examination showed contrast enhancement of the right occipital and frontoparietal cortical regions, which returned to normal one day after. The patient also fully recovered from the neurological symptoms within 24 h. We discussed the possible mechanism for blood-brain barrier disruption in this case. (orig.)

  2. Transient partial amnesia complicating cardiac and peripheral arteriography with nonionic contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Yildiz, A.; Yencilek, E.; Apaydin, F.D.; Duce, M.N.; Oezer, C. [Dept. of Radiology, Mersin Ueniv. Tip Fakueltesi Sokak Mersin (Turkey); Atalay, A. [Dept. of Cardiology, Mersin Ueniv. Tip Fakueltesi Sokak Mersin (Turkey)

    2003-12-01

    The aim of this study was to present a case of disruption of the blood-brain barrier during the coronary and lower extremity angiographies with radiological and clinical findings. This condition was secondary to intraarterial use of a nonionic, monomeric contrast medium. A total of 450 cc contrast media was used. Computed tomography examination showed contrast enhancement of the right occipital and frontoparietal cortical regions, which returned to normal one day after. The patient also fully recovered from the neurological symptoms within 24 h. We discussed the possible mechanism for blood-brain barrier disruption in this case. (orig.)

  3. Evaluation of changes in vertebral body density following administration of contrast medium during routine CT examination

    International Nuclear Information System (INIS)

    Janicek, M.; Bruna, J.; Stenhova, H.

    1984-01-01

    The possibility is discussed of depicting changes in the density of spongiosis of the vertebral body in normal patients after intravenous administration of a bolus of 40 ml 60% Diazetrizoate in the course of a routine CT examination. The average increase in density immediately after the administration of the contrast medium is 12 H (8%), in the course of 10 minutes is reduced to 5 H (4%) against the initial values in native examination. These average changes are statistically significant, in individual patients, however, the increase in density following the administration of a contrast medium fluctuates considerably (from 0.7% to 10%). Only systematic comparison with various pathological conditions will make it possible to assess the possibilities of the evaluation of the structure of the vertebral body in routine CT with the administration of a contrast medium into the blood flow. (author)

  4. Variable effects of soman on macromolecular secretion by ferret trachea

    International Nuclear Information System (INIS)

    McBride, R.K.; Zwierzynski, D.J.; Stone, K.K.; Culp, D.J.; Marin, M.G.

    1991-01-01

    The purpose of this study was to examine the effect of the anticholinesterase agent, soman, on macromolecular secretion by ferret trachea, in vitro. We mounted pieces of ferret trachea in Ussing-type chambers. Secreted sulfated macromolecules were radiolabeled by adding 500 microCi of 35 SO 4 to the submucosal medium and incubating for 17 hr. Soman added to the submucosal side produced a concentration-dependent increase in radiolabeled macromolecular release with a maximal secretory response (mean +/- SD) of 202 +/- 125% (n = 8) relative to the basal secretion rate at a concentration of 10 - 7 M. The addition of either 10 -6 M pralidoxime (acetylcholinesterase reactivator) or 10 -6 M atropine blocked the response to 10 -7 M soman. At soman concentrations greater than 10 -7 M, secretion rate decreased and was not significantly different from basal secretion. Additional experiments utilizing acetylcholine and the acetylcholinesterase inhibitor, physostigmine, suggest that inhibition of secretion by high concentrations of soman may be due to a secondary antagonistic effect of soman on muscarinic receptors

  5. Duplex-assisted carotid artery stenting without administration of contrast medium for patients with chronic kidney disease or allergic reaction.

    Science.gov (United States)

    Mizowaki, Takashi; Fujita, Atsushi; Imahori, Taichiro; Uyama, Atsushi; Inoue, Satoshi; Kohta, Masaaki; Hamaguchi, Hirotoshi; Sasayama, Takashi; Hosoda, Kohkichi; Kohmura, Eiji

    2016-07-01

    We aimed to investigate the safety and feasibility of duplex-assisted carotid artery stenting (CAS) without administration of contrast medium for the prevention of adverse reactions. Fifteen patients (9 % of all CASs) with severe carotid stenosis (≥70 %) associated with chronic kidney disease (CKD) (stage ≥3) or allergy to contrast medium underwent duplex-assisted CAS without administration of contrast medium over 4 years. The procedural success rate and perioperative complication rates were compared between the duplex-assisted CAS (n = 15) and conventional CAS (n = 153) groups. The technical success rate was 100 % in both groups. Combined stroke or death rates during the post-procedural period did not differ significantly between the duplex-assisted CAS group (0/15, 0 %) and conventional CAS group (4/153, 2.6 %). None of the 14 patients with CKD in the duplex-assisted CAS group experienced further deterioration of renal function. The mean surface radiation dose of participants in the duplex-assisted CAS group (n = 13, 312 ± 131 mGy) was significantly lower than that of the conventional CAS group (n = 31, 1036 ± 571 mGy) (p duplex-assisted CAS group (156 ± 39.7 min) and the conventional CAS group (156 ± 37.4 min). Duplex-assisted CAS without administration of contrast medium could be an alternative option in selected patients deemed to be at high risk for renal failure from nephrotoxic contrast medium or who have an allergy to contrast medium.

  6. Digital subtraction angiography and intraarterial contrast medium injection for coronary examinations

    Energy Technology Data Exchange (ETDEWEB)

    Tobio, R; Kallmeyer, C; Castello, J

    1985-01-01

    Digital subtraction angiography (DSA) is an established method of vasography, most extensively used as i.v. DSA. Intraarterial injection, however, applying selective or non-selective contrast medium injection, seems to be at least as important a technique although it has not yet met with corresponding interest. The article explains advantages of the technique for angiographic examinations, in particular of coronary angiography.

  7. Automated contrast medium monitoring system for computed tomography--Intra-institutional audit.

    Science.gov (United States)

    Lauretti, Dario Luca; Neri, Emanuele; Faggioni, Lorenzo; Paolicchi, Fabio; Caramella, Davide; Bartolozzi, Carlo

    2015-12-01

    The aim of this study was to analyze the usage and the data recorded by a RIS-PACS-connected contrast medium (CM) monitoring system (Certegra(®), Bayer Healthcare, Leverkusen, Germany) over 19 months of CT activity. The system used was connected to two dual syringe power injectors (each associated with a 16-row and a high definition 64-row multidetector CT scanner, respectively), allowing to manage contrast medium injection parameters and to send and retrieve CT study-related information via RIS/PACS for any scheduled contrast-enhanced CT examination. The system can handle up to 64 variables and can be accessed via touchscreen by CT operators as well as via a web interface by registered users with three different hierarchy levels. Data related to CM injection parameters (i.e. iodine concentration, volume and flow rate of CM, iodine delivery rate and iodine dose, CM injection pressure, and volume and flow rate of saline), patient weight and height, and type of CT study over a testing period spanning from 1 June 2013 to 10 January 2015 were retrieved from the system. Technical alerts occurred for each injection event (such as system disarm due to technical failure, disarm due to operator's stop, incomplete filling of patient data fields, or excessively high injection pressure), as well as interoperability issues related to data sending and receiving to/from the RIS/PACS were also recorded. During the testing period, the CM monitoring system generated a total of 8609 reports, of which 7629 relative to successful injection events (88.6%). 331 alerts were generated, of which 40 resulted in injection interruption and 291 in CM flow rate limitation due to excessively high injection pressure (>325 psi). Average CM volume and flow rate were 93.73 ± 17.58 mL and 3.53 ± 0.89 mL/s, and contrast injection pressure ranged between 5 and 167 psi. A statistically significant correlation was found between iodine concentration and peak IDR (rs=0.2744, psystems can provide a full

  8. Practical macromolecular cryocrystallography

    Energy Technology Data Exchange (ETDEWEB)

    Pflugrath, J. W., E-mail: jim.pflugrath@gmail.com [Rigaku Americas Corp., 9009 New Trails Drive, The Woodlands, TX 77381 (United States)

    2015-05-27

    Current methods, reagents and experimental hardware for successfully and reproducibly flash-cooling macromolecular crystals to cryogenic temperatures for X-ray diffraction data collection are reviewed. Cryocrystallography is an indispensable technique that is routinely used for single-crystal X-ray diffraction data collection at temperatures near 100 K, where radiation damage is mitigated. Modern procedures and tools to cryoprotect and rapidly cool macromolecular crystals with a significant solvent fraction to below the glass-transition phase of water are reviewed. Reagents and methods to help prevent the stresses that damage crystals when flash-cooling are described. A method of using isopentane to assess whether cryogenic temperatures have been preserved when dismounting screened crystals is also presented.

  9. Investigation of a potential macromolecular MRI contrast agent prepared from PPI (G = 2, polypropyleneimine, generation 2) dendrimer bifunctional chelates

    Science.gov (United States)

    Wang, Jianxin Steven

    The long-term objective is to develop magnetic resonance (MR) contrast agents that actively and passively target tumors for diagnosis and therapy. Many diagnostic imaging techniques for cancer lack specificity. A dendrimer based magnetic resonance imaging contrast agent has been developed with large proton relaxation enhancements and high molecular relaxivities. A new type of linear dendrimer based MRI contrast agent that is built from the polypropyleneimine and polyamidoamine dendrimers in which free amines have been conjugated to the chelate DTPA, which further formed the complex with Gadolinium (Gd) was studied. The specific research goals were to test the hypothesis that a linear chelate with macromolecular agents can be used in vitro and in vivo. This work successfully examined the adequacy and viability of the application for this agent in vitro and in vivo. A small animal whole body counter was designed and constructed to allow us to monitor biodistribution and kinetic mechanisms using a radioisotope labeled complex. The procedures of metal labeling, separation and purification have been established from this work. A biodistribution study has been performed using radioisotope induced organ/tissue counting and gamma camera imaging. The ratio of percentage of injected dose per gram organ/tissue for kidney and liver is 3.71 from whole body counter and 3.77 from the gamma camera. The results suggested that retention of Gd (III) is too high and a more kinetically stable chelate should be developed. The pharmacokinetic was evaluated in the whole animal model with the whole body clearance, and a kinetics model was developed. The pharmacokinetic results showed a bi-exponential decay in the animal model with two component excretion constants 1.43e(-5) and 0.0038511, which give half-lives of 3 hours and 33.6 days, respectively. Magnetic resonance imaging of this complex resulted in a 52% contrast enhancement in the rat kidney following the agents' administration in

  10. Enhancement effects of test injection with a small amount of MR contrast medium in the oral and maxillofacial region

    International Nuclear Information System (INIS)

    Yanagi, Yoshinobu; Asaumi, Jun-ichi; Konouchi, Hironobu; Hisatomi, Miki; Matsuzaki, Hidenobu; Murakami, Jun; Maki, Yuu; Unetsubo, Teruhisa; Kishi, Kanji

    2006-01-01

    Purpose: To examine whether the signal intensity of dynamic contrast-enhanced MRI (DCE-MRI) is altered by test injection of 1 ml of contrast medium, and if so, whether this change affects the DCE-MRI analysis. Materials and methods: Six healthy volunteers were examined by DCE-MRI using a Magnevist syringe and/or an Omniscan syringe for the injection of contrast medium. Each scan was performed 10 times using steady-state free precession (3D-FISP), a sequence for DCE-MRI, before and after intravenous injection of 1 ml of the contrast medium. The internal pterygoid muscle, masseter muscle, tongue, parotid gland, submandibular gland, bone marrow of the mandible, subcutaneous adipose tissue, and common carotid artery were determined to be regions of interest (ROI), and the ROI internal average signal intensity was measured. The 10 data sets obtained before or after contrast medium administration for each ROI were evaluated using the paired t-test. Results: The test injection increased the signal intensities of six of eight ROIs, with all 20 experiments in the submandibular gland showing significant differences. There was no significant difference in the two ROIs corresponding to the carotid artery and subcutaneous adipose tissue of the cheek. Conclusions: The enhanced signal intensity in the tissue might have been caused by the small amount of contrast medium in the test injection. To eliminate this discrepancy caused by the test injection, a pre-contrast scan should be performed when the average signal intensity of an ROI is measured. We therefore believe that the data obtained before a test injection may be important in the analysis of DCE-MRI

  11. Lecithine as an adjuvant in resorption of contrast medium in oral cholecystography

    International Nuclear Information System (INIS)

    Lindgren, I.

    1978-01-01

    No or poor filling of the gallbladder was obtained in 21 patients at cholecystography. They were re-examined after 10 days or later with the addition of lecithine to the contrast medium. The filling of the gallbladder, which was without abnormality, was improved in all cases. The mechanism of this effect is discussed. (Auth.)

  12. Macromolecular crystallography using synchrotron radiation

    International Nuclear Information System (INIS)

    Bartunik, H.D.; Phillips, J.C.; Fourme, R.

    1982-01-01

    The use of synchrotron X-ray sources in macromolecular crystallography is described. The properties of synchrotron radiation relevant to macromolecular crystallography are examined. The applications discussed include anomalous dispersion techniques, the acquisition of normal and high resolution data, and kinetic studies of structural changes in macromolecules; protein data are presented illustrating these applications. The apparatus used is described including information on the electronic detectors, the monitoring of the incident beam and crystal cooling. (U.K.)

  13. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT--a pooled analysis of two randomized trials

    DEFF Research Database (Denmark)

    Thomsen, Henrik S; Morcos, Sameh K

    2009-01-01

    of the LOCM were also observed in patients with GFR contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM......The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients...... with glomerular filtration rate (GFR) contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients...

  14. Iopamidol, a new non-ionic X-ray contrast medium

    International Nuclear Information System (INIS)

    Hagen, B.

    1982-01-01

    Iopamidol, a new non-ionic, monomeric contrast medium with low osmolality has been well established in our angiographic routine procedures according to the favourable results obtained in more than 300 controlled trials. The general tolerance (demonstrated by the rate of systemic adverse reactions) of the lower concentrated solution (300 mg iodine/ml is a little bit better than that of the higher concentrated one (370 mg iodine/ml). We could demonstrate a significant difference between the two preparations related to local side effects such as pain and heat sensations. The results of 100 intraindividual double blind studies (only peripheral angiography) specially referred to local side effects showed the high significant decrease of pain and heat sensations after application of Iopamidol compared to the results gained by the ionic Ioxitalamate and Ioglicinate. There was no remarkable difference between Iopamidol and Ioxaglate which is a dimeric but likewise low osmolar substance. The role of osmolality in the generation of side effects is pointed out. In consequence the advantages of using contrast media of reducted osmolality particularly in peripheral angiography must be emphasized. (orig.)

  15. Effect of barium sulfate contrast medium on rheology and sensory texture attributes in a model food.

    Science.gov (United States)

    Ekberg, O; Bulow, M; Ekman, S; Hall, G; Stading, M; Wendin, K

    2009-03-01

    The swallowing process can be visualized using videoradiography, by mixing food with contrast medium, e.g., barium sulfate (BaSO(4)), making it radiopaque. The sensory properties of foods may be affected by adding this medium. To evaluate if and to what extent sensory and rheological characteristics of mango purée were altered by adding barium sulfate to the food. This study evaluated four food samples based on mango purée, with no or added barium sulfate contrast medium (0%, 12.5%, 25.0%, and 37.5%), by a radiographic method, and measured sensory texture properties and rheological characteristics. The sensory evaluation was performed by an external trained panel using quantitative descriptive analysis. The ease of swallowing the foods was also evaluated. The sensory texture properties of mango purée were significantly affected by the added barium in all evaluated attributes, as was the perception of particles. Moreover, ease of swallowing was significantly higher in the sample without added contrast medium. All samples decreased in extensional viscosity with increasing extension rate, i.e., all samples were tension thinning. Shear viscosity was not as dependent on the concentration of BaSO(4) as extensional viscosity. Addition of barium sulfate to a model food of mango purée has a major impact on perceived sensory texture attributes as well as on rheological parameters.

  16. MR lymphography with macromolecular Gd-DTPA compounds

    International Nuclear Information System (INIS)

    Hamm, B.; Wagner, S.; Branding, G.; Taupitz, M.; Wolf, K.J.

    1990-01-01

    This paper investigates the suitability of macromolecular Gd-DTPA compounds as signal-enhancing lymphographic agents in MR imaging. Two Gd-DTPA polylysin compounds and Gd-DTPA albumin, with molecular weights of 48,000,170,000, and 87,000 daltons, respectively, were tested in rabbits at gadolinium doses of 5 and 15 μmol per animal. Three animals were examined at each dose with T1-weighted sequences. The iliac lymph nodes were imaged prior to and during unilateral endolymphatic infusion into a femoral lymph vessel as well as over a period of 2 hours thereafter. All contrast media showed a homogeneous and pronounced signal enhancement in the lymph nodes during infusion at both doses

  17. Magnetic resonance tomography for focal lesions in the liver using the para-magnetic contrast medium gadolinium DTPA

    International Nuclear Information System (INIS)

    Hamm, B.; Roemer, T.; Felix, R.; Wolf, K.J.; Klinikum Charlottenburg, Berlin

    1986-01-01

    The use of the para-magnetic contrast medium gadolinium DTPA for magnetic resonance tomography of focal lesions in the liver was investigated in 31 patients. Two dosage schedules of the contrast medium (0.1 and 0.2 mmol/kg body weight) were used with field strengths of 0.35 and 0.5 Tesla. Using T 1 sequences, gadolinium DTPA showed increased signal intensity in the liver and in tumours, but this was significantly more marked in the tumour. On T 1 spin-echo sequences, previously iso-intense lesions became visible after administration of contrast. On the other hand, contrast-enhanced lesions were less well seen on inversion recovery sequences because of a reduction in the contrast between tumour and liver tissue. The contrast between tumour and liver tissue was not improved by gadolinium DTPA in comparison with precontrast inversion recovery sequences and T 2 spin-echo sequences. The perfusion of intra-hepatic tumours could be elucidated by magnetic resonance tomography after the administration of gadolinium DTPA. (orig.) [de

  18. Time-efficient, high-resolution, whole brain three-dimensional macromolecular proton fraction mapping.

    Science.gov (United States)

    Yarnykh, Vasily L

    2016-05-01

    Macromolecular proton fraction (MPF) mapping is a quantitative MRI method that reconstructs parametric maps of a relative amount of macromolecular protons causing the magnetization transfer (MT) effect and provides a biomarker of myelination in neural tissues. This study aimed to develop a high-resolution whole brain MPF mapping technique using a minimal number of source images for scan time reduction. The described technique was based on replacement of an actually acquired reference image without MT saturation by a synthetic one reconstructed from R1 and proton density maps, thus requiring only three source images. This approach enabled whole brain three-dimensional MPF mapping with isotropic 1.25 × 1.25 × 1.25 mm(3) voxel size and a scan time of 20 min. The synthetic reference method was validated against standard MPF mapping with acquired reference images based on data from eight healthy subjects. Mean MPF values in segmented white and gray matter appeared in close agreement with no significant bias and small within-subject coefficients of variation (maps demonstrated sharp white-gray matter contrast and clear visualization of anatomical details, including gray matter structures with high iron content. The proposed synthetic reference method improves resolution of MPF mapping and combines accurate MPF measurements with unique neuroanatomical contrast features. © 2015 Wiley Periodicals, Inc.

  19. The predictive value of the product of contrast medium volume and urinary albumin/creatinine ratio in contrast-induced acute kidney injury.

    Science.gov (United States)

    Wang, Chunrui; Ma, Shuai; Deng, Bo; Lu, Jianxin; Shen, Wei; Jin, Bo; Shi, Haiming; Ding, Feng

    2017-11-01

    Preexisting renal impairment and the amount of contrast media are the most important risk factors for contrast-induced acute kidney injury (CI-AKI). We aimed to investigate whether the product of contrast medium volume and urinary albumin/creatinine ratio (CMV × UACR) would be a better predictor of CI-AKI in patients undergoing nonemergency coronary interventions. This was a prospective single-center observational study, and 912 consecutive patients who were exposed to contrast media during coronary interventions were investigated prospectively. CI-AKI is defined as a 44.2 μmol/L rise in serum creatinine or a 25% increase, assessed within 48 h after administration of contrast media in the absence of other causes. Fifty patients (5.48%) developed CI-AKI. The urinary albumin/creatinine ratio (UACR) (OR = 1.002, 95% CI = 1.000-1.003, p = .012) and contrast medium volume (CMV) (OR = 1.008, 95% CI = 1.001-1.014, p = .017) were independent risk factors for the development of CI-AKI. The area under the ROC curve of CMV, UACR and CMV × UACR were 0.662 (95% CI = 0.584-0.741, p < .001), 0.761 (95% CI = 0.674-0.847, p < .001) and 0.808 (95% CI = 0.747-0.896, p < .001), respectively. The cutoff value of CMV × UACR to predict CI-AKI was 1186.2, with 80.0% sensitivity and 62.2% specificity. The product of CMV and UACR (CMV × UACR) might be a predictor of CI-AKI in patients undergoing nonemergency coronary interventions, which was superior to CMV or UACR alone.

  20. Multi-modal magnetic resonance imaging and histology of vascular function in xenografts using macromolecular contrast agent hyperbranched polyglycerol (HPG-GdF).

    Science.gov (United States)

    Baker, Jennifer H E; McPhee, Kelly C; Moosvi, Firas; Saatchi, Katayoun; Häfeli, Urs O; Minchinton, Andrew I; Reinsberg, Stefan A

    2016-01-01

    Macromolecular gadolinium (Gd)-based contrast agents are in development as blood pool markers for MRI. HPG-GdF is a 583 kDa hyperbranched polyglycerol doubly tagged with Gd and Alexa 647 nm dye, making it both MR and histologically visible. In this study we examined the location of HPG-GdF in whole-tumor xenograft sections matched to in vivo DCE-MR images of both HPG-GdF and Gadovist. Despite its large size, we have shown that HPG-GdF extravasates from some tumor vessels and accumulates over time, but does not distribute beyond a few cell diameters from vessels. Fractional plasma volume (fPV) and apparent permeability-surface area product (aPS) parameters were derived from the MR concentration-time curves of HPG-GdF. Non-viable necrotic tumor tissue was excluded from the analysis by applying a novel bolus arrival time (BAT) algorithm to all voxels. aPS derived from HPG-GdF was the only MR parameter to identify a difference in vascular function between HCT116 and HT29 colorectal tumors. This study is the first to relate low and high molecular weight contrast agents with matched whole-tumor histological sections. These detailed comparisons identified tumor regions that appear distinct from each other using the HPG-GdF biomarkers related to perfusion and vessel leakiness, while Gadovist-imaged parameter measures in the same regions were unable to detect variation in vascular function. We have established HPG-GdF as a biocompatible multi-modal high molecular weight contrast agent with application for examining vascular function in both MR and histological modalities. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Macromolecular crystallization in microgravity

    International Nuclear Information System (INIS)

    Snell, Edward H; Helliwell, John R

    2005-01-01

    Density difference fluid flows and sedimentation of growing crystals are greatly reduced when crystallization takes place in a reduced gravity environment. In the case of macromolecular crystallography a crystal of a biological macromolecule is used for diffraction experiments (x-ray or neutron) so as to determine the three-dimensional structure of the macromolecule. The better the internal order of the crystal then the greater the molecular structure detail that can be extracted. It is this structural information that enables an understanding of how the molecule functions. This knowledge is changing the biological and chemical sciences, with major potential in understanding disease pathologies. In this review, we examine the use of microgravity as an environment to grow macromolecular crystals. We describe the crystallization procedures used on the ground, how the resulting crystals are studied and the knowledge obtained from those crystals. We address the features desired in an ordered crystal and the techniques used to evaluate those features in detail. We then introduce the microgravity environment, the techniques to access that environment and the theory and evidence behind the use of microgravity for crystallization experiments. We describe how ground-based laboratory techniques have been adapted to microgravity flights and look at some of the methods used to analyse the resulting data. Several case studies illustrate the physical crystal quality improvements and the macromolecular structural advances. Finally, limitations and alternatives to microgravity and future directions for this research are covered. Macromolecular structural crystallography in general is a remarkable field where physics, biology, chemistry and mathematics meet to enable insight to the fundamentals of life. As the reader will see, there is a great deal of physics involved when the microgravity environment is applied to crystallization, some of it known, and undoubtedly much yet to

  2. Comparison between two positive and one negative oral contrast medium for abdominal CT diagnosis

    International Nuclear Information System (INIS)

    Zwaan, M.; Gmelin, E.

    1989-01-01

    In a prospective randomised study three groups of 30 patients each were subjected to CT of the entire abdomen. The oral intestinal contrast media used were iodine solution (2%), barium suspension (1.5%) and paraffin emulsion (25%). The results were evaluated according to imaging, artifacts, assessability of the intestinal wall, taste and side effects. All three contrast media are suitable for marking the gastrointestinal tract; paraffin shows advantages in the upper part of the tract and is the only medium that enables assessment of the wall, while causing the lowest rate of artifacts. Barium has a high acceptance and the best tolerance of all contrast agents. (orig.) [de

  3. Sequential recovery of macromolecular components of the nucleolus.

    Science.gov (United States)

    Bai, Baoyan; Laiho, Marikki

    2015-01-01

    The nucleolus is involved in a number of cellular processes of importance to cell physiology and pathology, including cell stress responses and malignancies. Studies of macromolecular composition of the nucleolus depend critically on the efficient extraction and accurate quantification of all macromolecular components (e.g., DNA, RNA, and protein). We have developed a TRIzol-based method that efficiently and simultaneously isolates these three macromolecular constituents from the same sample of purified nucleoli. The recovered and solubilized protein can be accurately quantified by the bicinchoninic acid assay and assessed by polyacrylamide gel electrophoresis or by mass spectrometry. We have successfully applied this approach to extract and quantify the responses of all three macromolecular components in nucleoli after drug treatments of HeLa cells, and conducted RNA-Seq analysis of the nucleolar RNA.

  4. Kinetics of intravenous radiographic contrast medium injections as used on CT: simulation with time delay differential equations in a basic human cardiovascular multicompartment model.

    Science.gov (United States)

    Violon, D

    2012-12-01

    To develop a multicompartment model of only essential human body components that predicts the contrast medium concentration vs time curve in a chosen compartment after an intravenous injection. Also to show that the model can be used to time adequately contrast-enhanced CT series. A system of linked time delay instead of ordinary differential equations described the model and was solved with a Matlab program (Matlab v. 6.5; The Mathworks, Inc., Natick, MA). All the injection and physiological parameters were modified to cope with normal or pathological situations. In vivo time-concentration curves from the literature were recalculated to validate the model. The recalculated contrast medium time-concentration curves and parameters are given. The results of the statistical analysis of the study findings are expressed as the median prediction error and the median absolute prediction error values for both the time delay and ordinary differential equation systems; these are situated well below the generally accepted maximum 20% limit. The presented program correctly predicts the time-concentration curve of an intravenous contrast medium injection and, consequently, allows an individually tailored approach of CT examinations with optimised use of the injected contrast medium volume, as long as time delay instead of ordinary differential equations are used. The presented program offers good preliminary knowledge of the time-contrast medium concentration curve after any intravenous injection, allowing adequate timing of a CT examination, required by the short scan time of present-day scanners. The injected volume of contrast medium can be tailored to the individual patient with no more contrast medium than is strictly needed.

  5. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic me....../min/1.73 m (2) is CIN risk threshold for intravenous contrast medium. • Hydration with either saline or sodium bicarbonate reduces CIN incidence. • Patients with eGFR = 60 ml/min/1.73 m (2) receiving contrast medium can continue metformin normally....

  6. MO-E-17A-02: Incorporation of Contrast Medium Dynamics in Anthropomorphic Phantoms: The Advent of 5D XCAT Models

    Energy Technology Data Exchange (ETDEWEB)

    Sahbaee, P [NC State University, Raleigh, NC (United States); Samei, E [Duke University Medical Center, Durham, NC (United States); Segars, W [Duke University, Durham, NC (United States)

    2014-06-15

    Purpose: To develop a unique method to incorporate the dynamics of contrast-medium propagation into the anthropomorphic phantom, to generate a five-dimensional (5D) patient model for multimodality imaging studies. Methods: A compartmental model of blood circulation network within the body was embodied into an extended cardiac-torso (4D-XCAT) patient model. To do so, a computational physiologic model of the human cardiovascular system was developed which includes a series of compartments representing heart, vessels, and organs. Patient-specific cardiac output and blood volume were used as inputs influenced by the weight, height, age, and gender of the patient's model. For a given injection protocol and given XCAT model, the contrast-medium transmission within the body was described by a series of mass balance differential equations, the solutions to which provided the contrast enhancement-time curves for each organ; thereby defining the tissue materials including the contrastmedium within the XCAT model. A library of time-dependent organ materials was then defined. Each organ in each voxelized 4D-XCAT phantom was assigned to a corresponding time-varying material to create the 5D-XCAT phantom in which the fifth dimension is blood/contrast-medium within the temporal domain. Results: The model effectively predicts the time-varying concentration behavior of various contrast-medium administration in each organ for different patient models as function of patient size (weight/height) and different injection protocol factors (injection rate and pattern, iodine concentration or volume). The contrast enhanced XCAT patient models was developed based on the concentration of iodine as a function of time after injection. Conclusion: Majority of medical imaging systems take advantage of contrast-medium administration in terms of better image quality, the effect of which was ignored in previous optimization studies. The study enables a comprehensive optimization of contrast

  7. Effects of changes in analytic variables and contrast medium on estimation of glomerular filtration rates by computed tomography in healthy dogs.

    Science.gov (United States)

    Matsuda, Yuri; Kishimoto, Miori; Kushida, Kazuya; Yamada, Kazutaka; Shimizu, Miki; Itoh, Hiroshi

    2017-09-01

    OBJECTIVE To investigate effects of changes in analytic variables and contrast medium osmolality on glomerular filtration rate estimated by CT (CT-GFR) in dogs. ANIMALS 4 healthy anesthetized Beagles. PROCEDURES GFR was estimated by inulin clearance, and dogs underwent CT-GFR with iodinated contrast medium (iohexol or iodixanol) in a crossover-design study. Dynamic renal CT scanning was performed. Patlak plot analysis was used to calculate GFR with the renal cortex or whole kidney selected as the region of interest. The renal cortex was analyzed just prior to time of the second cortical attenuation peak. The whole kidney was analyzed 60, 80, 100, and 120 seconds after the appearance of contrast medium. Automated GFR calculations were performed with preinstalled perfusion software including 2 noise reduction levels (medium and strong). The CT-GFRs were compared with GFR estimated by inulin clearance. RESULTS There was no significant difference in CT-GFR with iohexol versus iodixanol in any analyses. The CT-GFR at the renal cortex, CT-GFR for the whole kidney 60 seconds after appearance of contrast medium, and CT-GFR calculated by perfusion software with medium noise reduction did not differ significantly from GFR estimated by inulin clearance. The CT-GFR was underestimated at ≥ 80 seconds after contrast medium appearance (whole kidney) and when strong noise reduction was used with perfusion CT software. CONCLUSIONS AND CLINICAL RELEVANCE Selection of the renal cortex as region of interest or use of the 60-second time point for whole-kidney evaluation yielded the best CT-GFR results. The perfusion software used produced good results with appropriate noise reduction. IMPACT FOR HUMAN MEDICINE The finding that excessive noise reduction caused underestimation of CT-GFR suggests that this factor should also be considered in CT-GFR examination of human patients.

  8. The role of macromolecular stability in desiccation tolerance

    NARCIS (Netherlands)

    Wolkers, W.F.

    1998-01-01

    The work presented in this thesis concerns a study on the molecular interactions that play a role in the macromolecular stability of desiccation-tolerant higher plant organs. Fourier transform infrared microspectroscopy was used as the main experimental technique to assess macromolecular

  9. Thermodynamics of Macromolecular Association in Heterogeneous Crowding Environments: Theoretical and Simulation Studies with a Simplified Model.

    Science.gov (United States)

    Ando, Tadashi; Yu, Isseki; Feig, Michael; Sugita, Yuji

    2016-11-23

    The cytoplasm of a cell is crowded with many different kinds of macromolecules. The macromolecular crowding affects the thermodynamics and kinetics of biological reactions in a living cell, such as protein folding, association, and diffusion. Theoretical and simulation studies using simplified models focus on the essential features of the crowding effects and provide a basis for analyzing experimental data. In most of the previous studies on the crowding effects, a uniform crowder size is assumed, which is in contrast to the inhomogeneous size distribution of macromolecules in a living cell. Here, we evaluate the free energy changes upon macromolecular association in a cell-like inhomogeneous crowding system via a theory of hard-sphere fluids and free energy calculations using Brownian dynamics trajectories. The inhomogeneous crowding model based on 41 different types of macromolecules represented by spheres with different radii mimics the physiological concentrations of macromolecules in the cytoplasm of Mycoplasma genitalium. The free energy changes of macromolecular association evaluated by the theory and simulations were in good agreement with each other. The crowder size distribution affects both specific and nonspecific molecular associations, suggesting that not only the volume fraction but also the size distribution of macromolecules are important factors for evaluating in vivo crowding effects. This study relates in vitro experiments on macromolecular crowding to in vivo crowding effects by using the theory of hard-sphere fluids with crowder-size heterogeneity.

  10. Arterial and venous blood pressure and blood flow following femoral angiography with a new non-ionic contrast medium

    International Nuclear Information System (INIS)

    Nyman, U.; Almen, T.

    1978-01-01

    At femoral angiography in dogs the effects of a new non-ionic contrast medium (C29) were compared with those of one non-ionic medium (metrizamide) and one ionic medium (meglumine/sodium diatrizoate) in current use. In the leg subjected to angiography the pressure gradient over the peripheral vessels decreased and the femoral blood flow increased. The changes induced by the ionic medium were significantly greater than those induced by metrizamide and C29, whereas no significant difference between the two non-ionic media was recorded. (Auth.)

  11. Analytical optimization of digital subtraction mammography with contrast medium using a commercial unit.

    Science.gov (United States)

    Rosado-Méndez, I; Palma, B A; Brandan, M E

    2008-12-01

    Contrast-medium-enhanced digital mammography (CEDM) is an image subtraction technique which might help unmasking lesions embedded in very dense breasts. Previous works have stated the feasibility of CEDM and the imperative need of radiological optimization. This work presents an extension of a former analytical formalism to predict contrast-to-noise ratio (CNR) in subtracted mammograms. The goal is to optimize radiological parameters available in a clinical mammographic unit (x-ray tube anode/filter combination, voltage, and loading) by maximizing CNR and minimizing total mean glandular dose (D(gT)), simulating the experimental application of an iodine-based contrast medium and the image subtraction under dual-energy nontemporal, and single- or dual-energy temporal modalities. Total breast-entrance air kerma is limited to a fixed 8.76 mGy (1 R, similar to screening studies). Mathematical expressions obtained from the formalism are evaluated using computed mammographic x-ray spectra attenuated by an adipose/glandular breast containing an elongated structure filled with an iodinated solution in various concentrations. A systematic study of contrast, its associated variance, and CNR for different spectral combinations is performed, concluding in the proposal of optimum x-ray spectra. The linearity between contrast in subtracted images and iodine mass thickness is proven, including the determination of iodine visualization limits based on Rose's detection criterion. Finally, total breast-entrance air kerma is distributed between both images in various proportions in order to maximize the figure of merit CNR2/D(gT). Predicted results indicate the advantage of temporal subtraction (either single- or dual-energy modalities) with optimum parameters corresponding to high-voltage, strongly hardened Rh/Rh spectra. For temporal techniques, CNR was found to depend mostly on the energy of the iodinated image, and thus reduction in D(gT) could be achieved if the spectral energy

  12. The design of macromolecular crystallography diffraction experiments

    International Nuclear Information System (INIS)

    Evans, Gwyndaf; Axford, Danny; Owen, Robin L.

    2011-01-01

    Thoughts about the decisions made in designing macromolecular X-ray crystallography experiments at synchrotron beamlines are presented. The measurement of X-ray diffraction data from macromolecular crystals for the purpose of structure determination is the convergence of two processes: the preparation of diffraction-quality crystal samples on the one hand and the construction and optimization of an X-ray beamline and end station on the other. Like sample preparation, a macromolecular crystallography beamline is geared to obtaining the best possible diffraction measurements from crystals provided by the synchrotron user. This paper describes the thoughts behind an experiment that fully exploits both the sample and the beamline and how these map into everyday decisions that users can and should make when visiting a beamline with their most precious crystals

  13. Magnetic Resonance Imaging in degenerative disease of the lumbar spine: Fat Saturation technique and contrast medium.

    Science.gov (United States)

    D'Aprile, Paola; Nasuto, Michelangelo; Tarantino, Alfredo; Cornacchia, Samantha; Guglielmi, Giuseppe; Jinkins, J Randy

    2018-01-19

    To examine both anterior and posterior elements of the lumbar spine in patients with low back pain using MRI T2-weighted sequences with Fat Saturation (FS) and contrast enhanced T1-weighted sequences with FS. Two thousand eight hundred and twenty (2820) patients (1628 male, 1192 female, mean age 54) presenting low back pain underwent MRI standard examination (Sagittal T1w TSE and T2w TSE, axial T1 SE) with the addition of sagittal and axial T2w Fat Sat (FS) sequences. Among all the patients, 987 (35%) have been studied adding Contrast Enhanced (CE) T1w FS sequences after administration of contrast medium. Among 987 patients studied with contrast medium, we found: active-inflammatory intervertebral osteochondrosis in 646 (65%) patients; degenerative-inflammatory changes in facet joints (facet joint effusion, synovitis, synovial cysts) in 462 (47%); spondylolysis in 69 (7%); degenerative-inflammatory changes of the flava, interspinous and supraspinous ligaments in 245 (25%); inflammatory changes of posterior perispinal muscles in 84 (8%) patients. In patients with suspected no-disc-related low back pain, the implementation of T2w FS and CE T1w FS sequences to the standard MR protocol could allow a better identification of degenerative-inflammatory changes more likely associated to the pain.

  14. A case of pulmonary edema developed after intraarterial injection of iodinated contrast medium

    International Nuclear Information System (INIS)

    Min, Byoung Chol; Chun, Kang Woo; Koh, Jae Hyu; Yoon, Jong Sup

    1982-01-01

    Pulmonary edema is a rare adverse reaction to the iodinated contrast medium. Complaining of huge abdominal mass, a 52 years old female was admitted to the Hangang Sungsim Hospital. On physical examination, the patient appeared to be healthy. She had stable vital signs, i.e. BP: 120/80 mmHg, pulse rate: 80/min.etc. An adult head sized mass was palpated in the left mid and lower abdomen. Otherwise nonspecific. On laboratory studies the positive findings were 8-10 WBC/HPF in urine, 25.6 mg/dl for BUN and PVC in EKG. It was negative for urine protein, serum creatinline and liver function test. We injected 100 ml and 30 ml of Urografin 60 through the abdominal aorta dividing 3 times and major branches of the abdominal aorta, respectively. Immediately after complicating angiography, interstitial pulmonary edema was found, showing blurring of the vascular margins, perivascular haziness and thickening of the interlobular septal lines in the both lower lung fields. The blood pressure was dropped to 80/60 mmHg, but pulse rate was normal. She did not complain of dyspnea, and cyanosis was not developed. The urine volume was normally maintained. She was treated for pulmonary edema, which was completely absorbed after 20 hours. And the blood pressure was also normalized. We have experienced a case of pulmonary edema developed after intraarterial injection of the iodinated contrast medium without underlying cardiac, renal and hepatic problems, and reviewed the literatures on mechanisms of pulmonary edema caused by intravascular injection of the iodinated contrast materials

  15. Clinical cardiovascular experiences with iopamidol: a new non-ionic contrast medium

    International Nuclear Information System (INIS)

    Partridge, J.B.; Robinson, P.J.; Turnbull, C.M.; Stoker, J.B.; Morrison, G.W.; Boyle, R.M.

    1981-01-01

    Iopamidol, a new non-ionic water-soluble contrast medium, has been compared with standard ionic media in a number of cardiovascular applications. It is stable in aqueous solution, is much less viscous and only slightly more osmolar than metrizamide. Compared to sodium meglumine diatrizoate in a series of 40 coronary arteriograms, it produced a consistent and highly significant decrease in the incidence and severity of hypotension and bradycardia following intracoronary injection. In the same group and in 62 children undergoing ventricular or great vessel angiocardiography, a subjective assessment of patient reaction showed that iopamidol was better tolerated than the ionic medium. There was a very strong patient preference for iopamidol in a group of 10 of the adult patients who had also consented to femoral artery injections of both media. Throughout these series there was no detectable difference in arterial image quality between the media. Venous phase opacification during arterioportography was assessed in 11 cases comparing iopamidol with sodium meglumine iothalamate. No significant difference was found. We conclude that iopamidol is clearly preferable to ionic media for routine cardiovascular applications. (author)

  16. Metabolic growth rate control in Escherichia coli may be a consequence of subsaturation of the macromolecular biosynthetic apparatus with substrates and catalytic components

    DEFF Research Database (Denmark)

    Jensen, Kaj Frank; Pedersen, Steen

    1990-01-01

    In this paper, the Escherichia coli cell is considered as a system designed for rapid growth, but limited by the medium. We propose that this very design causes the cell to become subsaturated with precursors and catalytic components at all levels of macromolecular biosynthesis and leads to a mol...

  17. Macromolecular crystallography beamline X25 at the NSLS

    Energy Technology Data Exchange (ETDEWEB)

    Héroux, Annie; Allaire, Marc; Buono, Richard; Cowan, Matthew L.; Dvorak, Joseph; Flaks, Leon; LaMarra, Steven; Myers, Stuart F.; Orville, Allen M.; Robinson, Howard H.; Roessler, Christian G.; Schneider, Dieter K.; Shea-McCarthy, Grace; Skinner, John M.; Skinner, Michael; Soares, Alexei S.; Sweet, Robert M.; Berman, Lonny E., E-mail: berman@bnl.gov [Brookhaven National Laboratory, PO Box 5000, Upton, NY 11973-5000 (United States)

    2014-04-08

    A description of the upgraded beamline X25 at the NSLS, operated by the PXRR and the Photon Sciences Directorate serving the Macromolecular Crystallography community, is presented. Beamline X25 at the NSLS is one of the five beamlines dedicated to macromolecular crystallography operated by the Brookhaven National Laboratory Macromolecular Crystallography Research Resource group. This mini-gap insertion-device beamline has seen constant upgrades for the last seven years in order to achieve mini-beam capability down to 20 µm × 20 µm. All major components beginning with the radiation source, and continuing along the beamline and its experimental hutch, have changed to produce a state-of-the-art facility for the scientific community.

  18. Macromolecular crystallography beamline X25 at the NSLS

    International Nuclear Information System (INIS)

    Héroux, Annie; Allaire, Marc; Buono, Richard; Cowan, Matthew L.; Dvorak, Joseph; Flaks, Leon; LaMarra, Steven; Myers, Stuart F.; Orville, Allen M.; Robinson, Howard H.; Roessler, Christian G.; Schneider, Dieter K.; Shea-McCarthy, Grace; Skinner, John M.; Skinner, Michael; Soares, Alexei S.; Sweet, Robert M.; Berman, Lonny E.

    2014-01-01

    A description of the upgraded beamline X25 at the NSLS, operated by the PXRR and the Photon Sciences Directorate serving the Macromolecular Crystallography community, is presented. Beamline X25 at the NSLS is one of the five beamlines dedicated to macromolecular crystallography operated by the Brookhaven National Laboratory Macromolecular Crystallography Research Resource group. This mini-gap insertion-device beamline has seen constant upgrades for the last seven years in order to achieve mini-beam capability down to 20 µm × 20 µm. All major components beginning with the radiation source, and continuing along the beamline and its experimental hutch, have changed to produce a state-of-the-art facility for the scientific community

  19. Abdominal multi-detector row CT: Effectiveness of determining contrast medium dose on basis of body surface area

    International Nuclear Information System (INIS)

    Onishi, Hiromitsu; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Osuga, Keigo; Tatsumi, Mitsuaki; Higashihara, Hiroki; Maeda, Noboru; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tomoda, Kaname; Tomiyama, Noriyuki

    2011-01-01

    Purpose: To investigate the validity of determining the contrast medium dose based on body surface area (BSA) for the abdominal contrast-enhanced multi-detector row CT comparing with determining based on body weight (BW). Materials and methods: Institutional review committee approval was obtained. In this retrospective study, 191 patients those underwent abdominal contrast-enhanced multi-detector row CT were enrolled. All patients received 96 mL of 320 mg I/mL contrast medium at the rate of 3.2 mL. The iodine dose required to enhance 1 HU of the aorta at the arterial phase and that of liver parenchyma at portal venous phase per BSA were calculated (EU BSA ) and evaluated the relationship with BSA. Those per BW were also calculated (EU BW ) and evaluated. Estimated enhancement values (EEVs) of the aorta and liver parenchyma with two protocols for dose decision based on BSA and BW were calculated and patient-to-patient variability was compared between two protocols using the Levene test. Results: The mean of EU BSA and EU BW were 0.0621 g I/m 2 /HU and 0.00178 g I/kg/HU for the aorta, and 0.342 g I/m 2 /HU and 0.00978 g I/kg/HU for the liver parenchyma, respectively. In the aortic enhancement, EU BSA was almost constant regardless of BSA, and the mean absolute deviation of the EEV with the BSA protocol was significantly lower than that with the BW protocol (P < .001), although there was no significant difference between two protocols in the hepatic parenchymal enhancement (P = .92). Conclusion: For the aortic enhancement, determining the contrast medium dose based on BSA was considered to improve patient-to-patient enhancement variability.

  20. Cytogenetic effects of cardioangiography on blood lymphocytes in children and in vitro effects of contrast medium and low dose radiation

    International Nuclear Information System (INIS)

    Nikula, E.; Kiviniitty, K.

    1987-01-01

    Structural chromosome aberrations were analysed in the peripheral blood lymphocytes of 15 children, aged 1 to 13 years, before, immediately after, 24 hours after and 6 to 8 months after cardioangiographic examination. Statistically significant increases were only demonstrated in the frequency of gaps and, consequently, in the frequency of aberrant cells immediately after cardioangiography. Most of the chromosome damage clearly disappeared within 24 hours. In addition, whole blood cultures were exposed in vitro to low dose radiation, a contrast medium, and radiation together with the contrast medium. No statistically significant differences could be observed in the chromosome aberration frequencies. It was concluded that the modern radiographic procedure, which uses very low radiation doses and less contrast medium, does not cause a consistent, permanent increase of chromosomal damage in the lymphocytes of children. However, the situation may be different if the child undergoes many radiography examinations or the radiation doses are high. (orig./MG)

  1. Contrast-enhanced peripheral MRA

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Thomsen, Henrik S

    2012-01-01

    MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic......-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged...... intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal...

  2. Polysorbate 80 and low-osmolality water-soluble contrast medium enema in diagnosis and treatment of faecal obstruction in malignant phaeochromocytoma

    International Nuclear Information System (INIS)

    Ratcliffe, J.F.

    1986-01-01

    Stercoral obstruction in a young woman with disseminated phaeochromocytoma was diagnosed and treated successfully using an enema of isosmolar iohexol (Omnipaque) and 1% polysorbate 80 (Tween 80) without complication. Surgical intervention was thus avoided. A low osmolality water-soluble contrast medium (iohexol 150 mg I/ml) with a wetting agent (1% Tween 80) was used because a barium suspension would have inspissated, exacerbating the constipation and a hyperosmolar contrast medium might have precipitated a hypertensive crisis and destablished her critical salt and water balance. (orig.)

  3. Perforations during contrast enema

    International Nuclear Information System (INIS)

    Vogel, H.; Steinkamp, U.; Grabbe, E.; Allgemeines Krankenhaus Ochsenzoll, Hamburg

    1983-01-01

    During contrast enema, perforation into the retroperitoneal space can be differentiated from perforation into the peritoneum and perforation into the intestinal wall associated with formation of barium granulomas or submucosal spreading of the contrast medium. Other special forms are perforation with contrast medium embolism of diverticula; of the processus vermiformis; penetration of contrast medium into fistulous systems and from the operated areas. Risk factors are: balloon catheter, intestinal tubes with a hard tip, preternatural anus, excessive enema pressure, contrast medium additions, preceding manipulations, intestinal diseases, advanced age and delegation of manipulations to assistants and unskilled staff. Children are particularly at risk. (orig.) [de

  4. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic me...

  5. Nuclear magnetic resonance diagnosis of cerebral tumours with the use of the contrast medium gadolinium-DTPA

    International Nuclear Information System (INIS)

    Schoerner, W.; Felix, R.; Claussen, C.; Fiegler, W.; Kazner, E.; Speck, U.; Niendorf, H.P.

    1984-01-01

    This study examines the effect of the NMR contrast medium gadolinium-DTPA on image contrast in cerebral tumours. Sixteen patients with space-occupying cerebral lesions were examined on a 0.35 Tesla superconducting scanner, using a T1-weighted spinecho sequence prior to and after the intravenous application of gadolinium-DTPA. In 8 patients T2-weighted spinecho-sequences were obtained before the administration of contrast. The tomograms were evaluated visually and according to quantitative criteria. The use of gadolinium-DTPA helps to evaluate the blood-brain barrier and improves diagnosis by differentiating tumour tissue from edema and from normal brain tissue. (orig.) [de

  6. Experimental investigations on the influence of the contrast medium Iopamiro 300 mixed with vegetal mucus on the nasolacrimal system and external eye tissues

    International Nuclear Information System (INIS)

    Rubaj, B.; Koper, S.; Wolski, T.; Toczowski, J.; Wolski, J.; Langwinska-Wosko, E.

    1994-01-01

    Using low osmolality, nonionized contrast medium Iopamiro-300, Bracco mixed with the mucus prepared from the seed flax (''Linum usitatissimum, L.''), a dacryocistorhinography was performed experimentally on 8 healthy mongrel dogs. Assessing the occurrence of local and general complications was the aim of the investigation. On the basis of a radiographic examination it has been shown that the mixture of the contrast medium and seed flax mucus appeared to be a very useful compound for dacryocistorhinography, especially for the evaluation of nasolacrimal duct system course and its patency. Clinical observations and a histological examination proved that this compound of the contrast medium was well tolerated by the mucous membrane of the nasolacrimal system and the external eye tissues. (author). 21 refs, 4 figs

  7. Macromolecular crowding directs extracellular matrix organization and mesenchymal stem cell behavior.

    Directory of Open Access Journals (Sweden)

    Adam S Zeiger

    Full Text Available Microenvironments of biological cells are dominated in vivo by macromolecular crowding and resultant excluded volume effects. This feature is absent in dilute in vitro cell culture. Here, we induced macromolecular crowding in vitro by using synthetic macromolecular globules of nm-scale radius at physiological levels of fractional volume occupancy. We quantified the impact of induced crowding on the extracellular and intracellular protein organization of human mesenchymal stem cells (MSCs via immunocytochemistry, atomic force microscopy (AFM, and AFM-enabled nanoindentation. Macromolecular crowding in extracellular culture media directly induced supramolecular assembly and alignment of extracellular matrix proteins deposited by cells, which in turn increased alignment of the intracellular actin cytoskeleton. The resulting cell-matrix reciprocity further affected adhesion, proliferation, and migration behavior of MSCs. Macromolecular crowding can thus aid the design of more physiologically relevant in vitro studies and devices for MSCs and other cells, by increasing the fidelity between materials synthesized by cells in vivo and in vitro.

  8. Macromolecular crowding directs extracellular matrix organization and mesenchymal stem cell behavior.

    Science.gov (United States)

    Zeiger, Adam S; Loe, Felicia C; Li, Ran; Raghunath, Michael; Van Vliet, Krystyn J

    2012-01-01

    Microenvironments of biological cells are dominated in vivo by macromolecular crowding and resultant excluded volume effects. This feature is absent in dilute in vitro cell culture. Here, we induced macromolecular crowding in vitro by using synthetic macromolecular globules of nm-scale radius at physiological levels of fractional volume occupancy. We quantified the impact of induced crowding on the extracellular and intracellular protein organization of human mesenchymal stem cells (MSCs) via immunocytochemistry, atomic force microscopy (AFM), and AFM-enabled nanoindentation. Macromolecular crowding in extracellular culture media directly induced supramolecular assembly and alignment of extracellular matrix proteins deposited by cells, which in turn increased alignment of the intracellular actin cytoskeleton. The resulting cell-matrix reciprocity further affected adhesion, proliferation, and migration behavior of MSCs. Macromolecular crowding can thus aid the design of more physiologically relevant in vitro studies and devices for MSCs and other cells, by increasing the fidelity between materials synthesized by cells in vivo and in vitro.

  9. Contrast medium-induced nephropathy: the pathophysiology

    DEFF Research Database (Denmark)

    Persson, P B; Tepel, Martin

    2006-01-01

    A widespread, rather general, definition of contrast-induced nephropathy (CIN) is an impairment in renal function occurring within 3 days following the intravascular administration of contrast media (CM) and the absence of an alternative aetiology. In spite of the vast clinical importance of CIN...... haemodynamics, regional hypoxia, auto-, and paracrine factors (adenosine, endothelin, reactive oxygen species) to direct cytotoxic effects. Although these potential mediators of CIN will be discussed separately, several factors may act in concert to perturb kidney function after exposure to contrast media. From...... the current knowledge of the mechanisms causing CIN, it is not possible to recommend a certain class of contrast media, except to avoid large doses of CM of the first generation. From a pathophysiological perspective, volume expansion is effective in avoiding CIN, since water permeability of the collecting...

  10. Vascularization of liver tumors - preliminary results with Coded Harmonic Angio (CHA), phase inversion imaging, 3D power Doppler and contrast medium-enhanced B-flow with second generation contrast agent (Optison).

    Science.gov (United States)

    Jung, E M; Kubale, R; Jungius, K-P; Jung, W; Lenhart, M; Clevert, D-A

    2006-01-01

    To investigate the dynamic value of contrast medium-enhanced ultrasonography with Optison for appraisal of the vascularization of hepatic tumors using harmonic imaging, 3D-/power Doppler and B-flow. 60 patients with a mean age of 56 years (range 35-76 years) with 93 liver tumors, including histopathologically proven hepatocellular carcinoma (HCC) [15 cases with 20 lesions], liver metastases of colorectal tumors [17 cases with 33 lesions], metastases of breast cancer [10 cases with 21 lesions] and hemangiomas [10 cases with 19 lesions] were prospectively investigated by means of multislice CT as well as native and contrast medium-enhanced ultrasound using a multifrequency transducer (2.5-4 MHz, Logig 9, GE). B scan was performed with additional color and power Doppler, followed by a bolus injection of 0.5 ml Optison. Tumor vascularization was evaluated with coded harmonic angio (CHA), pulse inversion imaging with power Doppler, 3D power Doppler and in the late phase (>5 min) with B-flow. In 15 cases with HCC, i.a. DSA was performed in addition. The results were also correlated with MRT and histological findings. Compared to spiral-CT/MRT, only 72/93 (77%) of the lesions could be detected in the B scan, 75/93 (81%) with CHA and 93/93 (100%) in the pulse inversion mode. Tumor vascularization was detectable in 43/93 (46%) of lesions with native power Doppler, in 75/93 (81%) of lesions after administering contrast medium in the CHA mode, in 81/93 (87%) of lesions in the pulse inversion mode with power Doppler and in 77/93 (83%) of lesions with contrast-enhanced B-flow. Early arterial and capillary perfusion was best detected with CHA, particularly in 20/20 (100%) of the HCC lesions, allowing a 3D reconstruction. 3D power Doppler was especially useful in investigating the tumor margins. Up to 20 min after contrast medium injection, B-flow was capable of detecting increased metastatic tumor vascularization in 42/54 (78%) of cases and intratumoral perfusion in 17/20 (85

  11. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.

    2005-01-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  12. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [Copenhagen University Hospital, Herlev (Denmark). Department of Diagnostic Radiology; Morcos, Sameh K. [Northern General Hospital, Department of Diagnostic Imaging, Sheffield Teaching Hospitals NHS Trust, Sheffield (United Kingdom)

    2005-04-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  13. The influence of different contrast medium concentrations and injection protocols on quantitative and clinical assessment of FDG–PET/CT in lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Verburg, Frederik A., E-mail: fverburg@ukaachen.de [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Kuhl, Christiane K. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Pietsch, Hubertus [Bayer Pharma AG, Berlin, Müllerstrasse 178, 13353 Berlin (Germany); Palmowski, Moritz [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Mottaghy, Felix M. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Behrendt, Florian F. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany)

    2013-10-01

    Objectives: To compare the effects of two different contrast medium concentrations for use in computed X-ray tomography (CT) employing two different injection protocols on positron emission tomography (PET) reconstruction in combined 2-{sup 18}F-desoxyglucose (FDG) PET/CT in patients with a suspicion of lung cancer. Methods: 120 patients with a suspicion of lung cancer were enrolled prospectively. PET images were reconstructed with the non-enhanced and venous phase contrast CT obtained after injection of iopromide 300 mg/ml or 370 mg/ml using either a fixed-dose or a body surface area adapted injection protocol. Maximum and mean standardized uptake values (SUVmax and SUVmean) and contrast enhancement (HU) were determined in the subclavian vein, ascending aorta, abdominal aorta, inferior vena cava, portal vein, liver and kidney and in the suspicious lung lesion. PET data were evaluated visually for the presence of malignancy and image quality. Results: At none of the sites a significant difference in the extent of the contrast enhancement between the four different protocols was found. However, the variability of the contrast enhancement at several anatomical sites was significantly greater in the fixed dose groups than in the BSA groups for both contrast medium concentrations. At none of the sites a significant difference was found in the extent of the SUVmax and SUVmean increase as a result of the use of the venous phase contrast enhanced CT for attenuation. Visual clinical evaluation of lesions showed no differences between contrast and non-contrast PET/CT (P = 0.32). Conclusions: Contrast enhanced CT for attenuation correction in combined PET/CT in lung cancer affects neither the clinical assessment nor image quality of the PET-images. A body surface adapted contrast medium protocol reduces the interpatient variability in contrast enhancement.

  14. Distribution and enzymatic activity of heterotrophic bacteria decomposing selected macromolecular compounds in a Baltic Sea sandy beach

    Science.gov (United States)

    Podgórska, B.; Mudryk, Z. J.

    2003-03-01

    The potential capability to decompose macromolecular compounds, and the level of extracellular enzyme activities were determined in heterotrophic bacteria isolated from a sandy beach in Sopot on the Southern Baltic Sea coast. Individual isolates were capable of hydrolysing a wide spectrum of organic macromolecular compounds. Lipids, gelatine, and DNA were hydrolyzed most efficiently. Only a very small percentage of strains were able to decompose cellulose, and no pectinolytic bacteria were found. Except for starch-hydrolysis, no significant differences in the intensity of organic compound decomposition were recorded between horizontal and vertical profiles of the studied beach. Of all the studied extracellular enzymes, alkaline phosphatase, esterase lipase, and leucine acrylaminidase were most active; in contrast, the activity α-fucosidase, α-galactosidase and β-glucouronidase was the weakest. The level of extracellular enzyme activity was similar in both sand layers.

  15. Effects of high iodine doses given parenterally as contrast medium on parameter of the pro/antioxidative balance

    International Nuclear Information System (INIS)

    Winkler, R.; Griebenow, S.; Scheidleder, B.; Bailer, H.

    2002-01-01

    The aim of this study was to investigate effects of high iodine doses given parenterally as contrast medium on parameters of lipid status and thyroid hormone status as well as on parameters of the pro/antioxidative balance of spa patients. 29 patients with a comparable indication who had to undergo an angiography were chosen. The blood parameters of these patients were determined before and after the angiographic treatment. No provable changes of the thyroid parameters f-T 3 , f-T 4 and TSH were found after the angiography. In case of enzyme activities, the protective enzymes SOD and GSHPX showed no changes, while the concentrations of peroxides and MDA were increased significantly. Corresponding to this, the total antioxidative status and the vitamin E level decreased significantly. Altogether these results stand for a moderate deterioration of the antioxidative protective potential by the highly iodine containing contrast medium. (author)

  16. The use of dilute calogen[reg] as a fat density oral contrast medium in upper abdominal computed tomography, compared with the use of water and positive oral contrast media

    International Nuclear Information System (INIS)

    Ramsay, Duncan W.; Markham, Derrian H.; Morgan, Bruno; Rodgers, Peter M.; Liddicoat, Amanda J.

    2001-01-01

    AIM: Oral contrast media are commonly given prior to computed tomography (CT) examination of the upper abdomen. Although positive oral contrast media are normally used, there is increasing interest in using negative agents such as water and less commonly fat density products. The aim of this study was to compare a positive oral contrast medium, water, and a diluted emulsion of arachis oil (Calogen[reg], a fat density food supplement) for assessment of the upper abdomen. MATERIALS AND METHODS: Seventy-one patients referred for upper abdominal CT were randomized to receive either 500 ml water, 2% sodium diatrizoate or a dilute suspension of Calogen[reg]. The CT images were scored independently by three radiologists. Distension and anatomical identification was assessed for the stomach, duodenum and jejunum; with anatomical identification recorded for the pancreas, retroperitoneum, liver, gallbladder and spleen. RESULTS: Dilute Calogen[reg] produced a significant improvement (P < 0.01) in distension and anatomical visualization of the stomach and proximal duodenum. Only minimal differences were demonstrated between the three contrast media for visualization of more distal small bowel or identification of the other upper abdominal viscera. Significantly more artifacts were caused by positive contrast media than with the Calogen[reg] mixture. CONCLUSION: A dilute suspension of Calogen[reg] as an oral contrast medium is recommended when disease is suspected within the stomach or proximal duodenum. Ramsay, D.W. et al. (2001)

  17. Estimation of shear velocity contrast for dipping or anisotropic medium from transmitted Ps amplitude variation with ray-parameter

    Science.gov (United States)

    Kumar, Prakash

    2015-12-01

    Amplitude versus offset analysis of P to P reflection is often used in exploration seismology for hydrocarbon exploration. In the present work, the feasibility to estimate crustal velocity structure from transmitted P to S wave amplitude variation with ray-parameter has been investigated separately for dipping layer and anisotropy medium. First, for horizontal and isotropic medium, the approximation of P-to-s conversion is used that is expressed as a linear form in terms of slowness. Next, the intercept of the linear regression has been used to estimate the shear wave velocity contrast (δβ) across an interface. The formulation holds good for isotropic and horizontal layer medium. Application of such formula to anisotropic medium or dipping layer data may lead to erroneous estimation of δβ. In order to overcome this problem, a method has been proposed to compensate the SV-amplitude using shifted version of SH-amplitude, and subsequently transforming SV amplitudes equivalent to that from isotropic or horizontal layer medium as the case may be. Once this transformation has been done, δβ can be estimated using isotropic horizontal layer formula. The shifts required in SH for the compensation are π/2 and π/4 for dipping layer and anisotropic medium, respectively. The effectiveness of the approach has been reported using various synthetic data sets. The methodology is also tested on real data from HI-CLIMB network in Himalaya, where the presence of dipping Moho has already been reported. The result reveals that the average shear wave velocity contrast across the Moho is larger towards the Indian side compared to the higher Himalayan and Tibetan regions.

  18. Studies on the consistency of internally taken contrast medium for pancreas CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Kishio; Mimura, Seiichi; Tahara, Seiji; Kitayama, Takuichi; Inamura, Keiji; Mikami, Yasutaka; Hashimoto, Keiji; Hiraki, Yoshio; Aono, Kaname

    1985-02-01

    A problem of Pancreatic CT scanning is the discrimination between the pancreas and the adjacent gastrointestinal tract. Generally we administer a dilution of gastrografin internally to make the discrimination. The degree of dilution has been decided by experience at each hospital. When the consistency of the contrast medium is low in density, an enhancement effect cannot be expected, but when the consistency is high, artifacts appear. We have experimented on the degree of the dilution and CT-No to decide the optimum consistency of gastrografin for the diagnosis of pancreatic disease. Statistical analysis of the results show the optimum dilution of gastrografin to be 1.5%.

  19. Dialysis and contrast media

    International Nuclear Information System (INIS)

    Morcos, Sameh K.; Thomsen, Henrik S.; Webb, Judith A.W.

    2002-01-01

    In a previous survey we revealed uncertainty among responders about (a) whether or not to perform hemodialysis in patients with severely reduced renal function who had received contrast medium; and (b) when to perform hemodialysis in patients on regular treatment with hemodialysis or continuous ambulatory dialysis who received contrast medium. Therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and to issue guidelines. The committee performed a Medline search. Based on this, a report and guidelines were prepared. The report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy. Hemodialysis and peritoneal dialysis safely remove both iodinated and gadolinium-based contrast media. The effectiveness of hemodialysis depends on many factors including blood and dialysate flow rate, permeability of dialysis membrane, duration of hemodialysis and molecular size, protein binding, hydrophilicity, and electrical charge of the contrast medium. Generally, several hemodialysis sessions are needed to removal all contrast medium, whereas it takes 3 weeks for continuous ambulatory dialysis to remove the agent completely. There is no need to schedule the dialysis in relation to the injection of iodinated or MR contrast media or the injection of contrast agent in relation to the dialysis program. Hemodialysis does not protect poorly functioning kidneys against contrast-medium-induced nephrotoxicity. Simple guidelines are given. (orig.)

  20. What Macromolecular Crowding Can Do to a Protein

    Science.gov (United States)

    Kuznetsova, Irina M.; Turoverov, Konstantin K.; Uversky, Vladimir N.

    2014-01-01

    The intracellular environment represents an extremely crowded milieu, with a limited amount of free water and an almost complete lack of unoccupied space. Obviously, slightly salted aqueous solutions containing low concentrations of a biomolecule of interest are too simplistic to mimic the “real life” situation, where the biomolecule of interest scrambles and wades through the tightly packed crowd. In laboratory practice, such macromolecular crowding is typically mimicked by concentrated solutions of various polymers that serve as model “crowding agents”. Studies under these conditions revealed that macromolecular crowding might affect protein structure, folding, shape, conformational stability, binding of small molecules, enzymatic activity, protein-protein interactions, protein-nucleic acid interactions, and pathological aggregation. The goal of this review is to systematically analyze currently available experimental data on the variety of effects of macromolecular crowding on a protein molecule. The review covers more than 320 papers and therefore represents one of the most comprehensive compendia of the current knowledge in this exciting area. PMID:25514413

  1. Optimizing Water Exchange Rates and Rotational Mobility for High-Relaxivity of a Novel Gd-DO3A Derivative Complex Conjugated to Inulin as Macromolecular Contrast Agents for MRI.

    Science.gov (United States)

    Granato, Luigi; Vander Elst, Luce; Henoumont, Celine; Muller, Robert N; Laurent, Sophie

    2018-02-01

    Thanks to the understanding of the relationships between the residence lifetime τ M of the coordinated water molecules to macrocyclic Gd-complexes and the rotational mobility τ R of these structures, and according to the theory for paramagnetic relaxation, it is now possible to design macromolecular contrast agents with enhanced relaxivities by optimizing these two parameters through ligand structural modification. We succeeded in accelerating the water exchange rate by inducing steric compression around the water binding site, and by removing the amide function from the DOTA-AA ligand [1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid mono(p-aminoanilide)] (L) previously designed. This new ligand 10[2(1-oxo-1-p-propylthioureidophenylpropyl]-1,4,7,10-tetraazacyclodecane-1,4,7-tetraacetic acid (L 1 ) was then covalently conjugated to API [O-(aminopropyl)inulin] to get the complex API-(GdL 1 )x with intent to slow down the rotational correlation time (τ R ) of the macromolecular complex. The evaluation of the longitudinal relaxivity at different magnetic fields and the study of the 17 O-NMR at variable temperature of the low-molecular-weight compound (GdL 1 ) showed a slight decrease of the τ M value (τM310 = 331 ns vs. τM310 = 450 ns for the GdL complex). Consequently to the increase of the size of the API-(GdL 1 )x complex, the rotational correlation time becomes about 360 times longer compared to the monomeric GdL 1 complex (τ R  = 33,700 ps), which results in an enhanced proton relaxivity. © 2018 Wiley-VHCA AG, Zurich, Switzerland.

  2. Medium chain glycerides of coconut oil for microwave-enhanced conversion of polycarbonate into polyols

    Czech Academy of Sciences Publication Activity Database

    Beneš, Hynek; Paruzel, Aleksandra; Trhlíková, Olga; Paruzel, Bartosz

    2017-01-01

    Roč. 86, January (2017), s. 173-187 ISSN 0014-3057 R&D Projects: GA MŠk(CZ) LO1507 Institutional support: RVO:61389013 Keywords : medium chain triglycerides * coconut oil * polycarbonate Subject RIV: CD - Macromolecular Chemistry OBOR OECD: Polymer science Impact factor: 3.531, year: 2016

  3. Macromolecular nanotheranostics for multimodal anticancer therapy

    Science.gov (United States)

    Huis in't Veld, Ruben; Storm, Gert; Hennink, Wim E.; Kiessling, Fabian; Lammers, Twan

    2011-10-01

    Macromolecular carrier materials based on N-(2-hydroxypropyl)methacrylamide (HPMA) are prototypic and well-characterized drug delivery systems that have been extensively evaluated in the past two decades, both at the preclinical and at the clinical level. Using several different imaging agents and techniques, HPMA copolymers have been shown to circulate for prolonged periods of time, and to accumulate in tumors both effectively and selectively by means of the Enhanced Permeability and Retention (EPR) effect. Because of this, HPMA-based macromolecular nanotheranostics, i.e. formulations containing both drug and imaging agents within a single formulation, have been shown to be highly effective in inducing tumor growth inhibition in animal models. In patients, however, as essentially all other tumor-targeted nanomedicines, they are generally only able to improve the therapeutic index of the attached active agent by lowering its toxicity, and they fail to improve the efficacy of the intervention. Bearing this in mind, we have recently reasoned that because of their biocompatibility and their beneficial biodistribution, nanomedicine formulations might be highly suitable systems for combination therapies. In the present manuscript, we briefly summarize several exemplary efforts undertaken in this regard in our labs in the past couple of years, and we show that long-circulating and passively tumor-targeted macromolecular nanotheranostics can be used to improve the efficacy of radiochemotherapy and of chemotherapy combinations.

  4. Multi-detector CT urography: effect of oral hydration and contrast medium volume on renal parenchymal enhancement and urinary tract opacification - a quantitative and qualitative analysis

    International Nuclear Information System (INIS)

    Szolar, Dieter H.; Tillich, Manfred; Preidler, Klaus W.

    2010-01-01

    To assess the effect of oral hydration and contrast-medium volume on renal enhancement and urinary tract opacification in multi-detector CT urography. A total of 192 patients were assigned to different protocols with varying doses of contrast agent with and without oral hydration. The attenuation was measured in the renal parenchyma in the unenhanced, nephrographic and excretory phase, and in the urinary tract in excretory phase imaging, respectively. Opacification of the urinary tract was graded on volume rendered images. Oral hydration did not significantly alter renal parenchymal enhancement in both the nephrographic and the excretory phase (p > 0.001), but significantly decreased mean attenuation of the urinary tract in the excretory phase (p ≤ 0.001), and improved continuous opacification of all ureter segments (p < 0.01). Higher volumes of contrast medium improved renal parenchymal enhancement (p ≤ 0.001) and continuous opacification of the urinary tract (p ≤ 0.01). Oral hydration leads to lower attenuation values in the urinary tract but improves the continuous opacification of the tract. Increase in contrast medium volume leads to higher renal parenchymal enhancement as well as to an increased continuous opacification of the urinary tract. Decrease in contrast medium volume cannot be compensated for by oral hydration in terms of parenchymal enhancement. (orig.)

  5. Recent advances in macromolecular prodrugs

    DEFF Research Database (Denmark)

    Riber, Camilla Frich; Zelikin, Alexander N.

    2017-01-01

    Macromolecular prodrugs (MP) are high molar mass conjugates, typically carrying several copies of a drug or a drug combination, designed to optimize delivery of the drug, that is — its pharmacokinetics. From its advent several decades ago, design of MP has undergone significant development and es...

  6. Evaluation of the acute adverse reaction of contrast medium with high and moderate iodine concentration in patients undergoing computed tomography

    International Nuclear Information System (INIS)

    Nagamoto, Masashi; Gomi, Tatsuya; Terada, Hitoshi; Terada, Shigehiko; Kohda, Eiichi

    2006-01-01

    The aim of this prospective study was to evaluate and compare acute adverse reactions between contrast medium containing moderate and high concentrations of iodine in patients undergoing computed tomography (CT). A total of 945 patients undergoing enhanced CT were randomly assigned to receive one of two doses of contrast medium. We then prospectively investigated the incidence of adverse reactions. Iopamidol was used as the contrast medium, with a high concentration of 370 mgI/ml and a moderate concentration of 300 mgI/ml. The frequency of adverse reactions, such as pain at the injection site and heat sensation, were determined. Acute adverse reactions were observed in 2.4% (11/458) of the moderate-concentration group compared to 3.11% (15/482) of the high-concentration group; there was no significant difference in incidence between the two groups. Most adverse reactions were mild, and there was no significant difference in severity. One patient in the high-concentration group was seen to have a moderate adverse reaction. No correlation existed between the incidence of adverse reactions and patient characteristics such as sex, age, weight, flow amount, and flow rate. The incidence of pain was not significantly different between the two groups. In contrast, the incidence of heat sensation was significantly higher in the high-concentration group. The incidence and severity of acute adverse reactions were not significantly different between the two groups, and there were no severe adverse reactions in either group. (author)

  7. Status and prospects of macromolecular crystallography

    Indian Academy of Sciences (India)

    technique that could be completely automated in most cases. ... major challenge in macromolecular crystallography today is ... tial characterization of crystals in the home source and make a ... opportunities for a generation of structural biolo-.

  8. Intracavitary application of contrast medium in the follow-up of complicated tube-drained pleural empyema: Conventional radiography vs CT

    International Nuclear Information System (INIS)

    Duex, M.; Bischoff, H.; Schmaehl, A.; Tuengerthal, S.

    1997-01-01

    Purpose: To define the value of conventional radiography compared with CT in the follow-up of complicated, long-term tube drained pleural empyema after intracavitary application of contrast medium. Methods: 28 patients with complicated pleural empyema (stage III) and longterm tube drainage were submitted to fluoroscopy of the pleural cavity and a CT of the thorax after contrast medium had been instilled into the pleural space. Both examinations were judged by the following criteria: Number and morphology of pleural cavities, quality of drainage and accompanying thoracic disease. Results: 49 pleural cavities were diagnosed. Judgement of drainage corresponded in 79% of cases and differed 21% with proof of further not drained cavities only on CT. 4 bronchopleural fistulas were diagnosed by fluoroscopy, of which only 2 were evident on CT. Accompanying thoracic disease was reliably detected by CT only. Conclusions: Diagnosis of bronchopleural fistulas and judgement of the pleural drainage is best possible using fluoroscopy after application of contrast medium into the pleural space. CT is most accurate to detect further cavities that have not been drained, to look for concomitant thoracic disease, and to judge the morphology of the pleural cavity. Conventional radiography of the pleural space is effective and recommended to be used as a first line investigation for the follow-up of stage III empyemas. Patients in poor general condition (fever, elevated blood markers indicating inflammation) should be examined by both fluoroscopy and CT. (orig.) [de

  9. Attenuation changes of the normal and ischemic canine kidney. Dynamic CT scanning after intravenous contrast medium bolus

    Energy Technology Data Exchange (ETDEWEB)

    Jaschke, W.; Lipton, M.J.; Boyd, D.P.; Cann, C.; Strauss, L.; Sievers, R.S.

    The potential of CT scanning to explore total and regional renal blood flow was evaluated in a dog model with unilateral renal artery stenosis (n=7, reduction of renal blood flow: 32-75% of base line flow). Attenuation versus time curves were generated for the renal cortex and medulla, as well as for the aorta and renal vein. A fast CT scanner was used which allowed for up to 24 scans/minute at the same level (slice thickness: 10 mm). A total of 10 ml contrast medim was injected into a peripheral vein for each scan series taken. During baseline conditions, the curve of the renal cortex and medulla demonstrated 2 peaks. The first peak was mainly related to early vascular enhancement, whereas the second peak corresponded mainly to the appearance of contrast medium in the distal convolutes and collecting ducts. Ischemia of the kidney resulted in a reduction of the first peak and a flattening of the leading edge slope. Transport of contrast medium through the extravascular compartments of the kidney was delayed during ischemia. Relative renal blood flow was obtained from the CT data by dividing peak enhancement by rise-time as assessed from the cortical curve. All measurements were related to baseline flow and validated by flow measurements using radioactive labeled microspheres (n=5). Correlation was found to be r=0.97. (orig.).

  10. Study of the safety of a new non-ionic contrast medium, iopromide 370 in patients with chronic renal failure

    International Nuclear Information System (INIS)

    Meyrier, A.; Fernet, M.; Rainfray, M.

    1989-01-01

    Intravenous injection of iodinated contrast media usually induces modifications of renal function. Adverse effects of contrast media on renal function may affect diuresis, blood flow or glomerular filtration rate. These modifications are mainly related to osmolality but also chemotoxicity. This open study showed that after i.v. injection of a bolus of iopromide 370, a new non-ionic contrast medium, there was no untoward effect on renal function in patients with renal insufficiency. This justifies comparative studies in patients with renal impairment including elderly subjects, to confirm the tolerance of this product in high risk groups [fr

  11. Radiation damage to nucleoprotein complexes in macromolecular crystallography

    International Nuclear Information System (INIS)

    Bury, Charles; Garman, Elspeth F.; Ginn, Helen Mary; Ravelli, Raimond B. G.; Carmichael, Ian; Kneale, Geoff; McGeehan, John E.

    2015-01-01

    Quantitative X-ray induced radiation damage studies employing a model protein–DNA complex revealed a striking partition of damage sites. The DNA component was observed to be far more resistant to specific damage compared with the protein. Significant progress has been made in macromolecular crystallography over recent years in both the understanding and mitigation of X-ray induced radiation damage when collecting diffraction data from crystalline proteins. In contrast, despite the large field that is productively engaged in the study of radiation chemistry of nucleic acids, particularly of DNA, there are currently very few X-ray crystallographic studies on radiation damage mechanisms in nucleic acids. Quantitative comparison of damage to protein and DNA crystals separately is challenging, but many of the issues are circumvented by studying pre-formed biological nucleoprotein complexes where direct comparison of each component can be made under the same controlled conditions. Here a model protein–DNA complex C.Esp1396I is employed to investigate specific damage mechanisms for protein and DNA in a biologically relevant complex over a large dose range (2.07–44.63 MGy). In order to allow a quantitative analysis of radiation damage sites from a complex series of macromolecular diffraction data, a computational method has been developed that is generally applicable to the field. Typical specific damage was observed for both the protein on particular amino acids and for the DNA on, for example, the cleavage of base-sugar N 1 —C and sugar-phosphate C—O bonds. Strikingly the DNA component was determined to be far more resistant to specific damage than the protein for the investigated dose range. At low doses the protein was observed to be susceptible to radiation damage while the DNA was far more resistant, damage only being observed at significantly higher doses

  12. Nanoparticles generated by laser in liquids as contrast medium and radiotherapy intensifiers

    Science.gov (United States)

    Restuccia, Nancy; Torrisi, Lorenzo

    2018-01-01

    The synthesis of Au and Ag nanoparticles (NP) though laser ablation in liquids as a function the laser parameters is presented. Spherical NPs with diameter distribution within 1 and 100 nm were prepared by laser ablation in water. The nanoparticles characterization was performed using optical spectroscopy and electronic microscopy (SEM and TEM) measurements. Studies of the possible use of metallic nanoparticles as intensifier of diagnostics imaging contrast medium and absorbing dose from ionizing radiations in traditional radiotherapy and protontherapy are presented. Examples of in vitro (in tissue equivalent materials) and in vivo (in mice), were conducted thank to simulation programs permitting to evaluate the enhancement of efficiency in imaging and therapy as a function of the NPs concentrations and irradiation conditions.

  13. Nanoparticles generated by laser in liquids as contrast medium and radiotherapy intensifiers

    Directory of Open Access Journals (Sweden)

    Restuccia Nancy

    2018-01-01

    Full Text Available The synthesis of Au and Ag nanoparticles (NP though laser ablation in liquids as a function the laser parameters is presented. Spherical NPs with diameter distribution within 1 and 100 nm were prepared by laser ablation in water. The nanoparticles characterization was performed using optical spectroscopy and electronic microscopy (SEM and TEM measurements. Studies of the possible use of metallic nanoparticles as intensifier of diagnostics imaging contrast medium and absorbing dose from ionizing radiations in traditional radiotherapy and protontherapy are presented. Examples of in vitro (in tissue equivalent materials and in vivo (in mice, were conducted thank to simulation programs permitting to evaluate the enhancement of efficiency in imaging and therapy as a function of the NPs concentrations and irradiation conditions.

  14. Automated data collection for macromolecular crystallography.

    Science.gov (United States)

    Winter, Graeme; McAuley, Katherine E

    2011-09-01

    An overview, together with some practical advice, is presented of the current status of the automation of macromolecular crystallography (MX) data collection, with a focus on MX beamlines at Diamond Light Source, UK. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Celebrating macromolecular crystallography: A personal perspective

    Directory of Open Access Journals (Sweden)

    Abad-Zapatero, Celerino

    2015-04-01

    Full Text Available The twentieth century has seen an enormous advance in the knowledge of the atomic structures that surround us. The discovery of the first crystal structures of simple inorganic salts by the Braggs in 1914, using the diffraction of X-rays by crystals, provided the critical elements to unveil the atomic structure of matter. Subsequent developments in the field leading to macromolecular crystallography are presented with a personal perspective, related to the cultural milieu of Spain in the late 1950’s. The journey of discovery of the author, as he developed professionally, is interwoven with the expansion of macromolecular crystallography from the first proteins (myoglobin, hemoglobin to the ‘coming of age’ of the field in 1971 and the discoveries that followed, culminating in the determination of the structure of the ribosomes at the turn of the century. A perspective is presented exploring the future of the field and also a reflection about the future generations of Spanish scientists.El siglo XX ha sido testigo del increíble avance que ha experimentado el conocimiento de la estructura atómica de la materia que nos rodea. El descubrimiento de las primeras estructuras atómicas de sales inorgánicas por los Bragg en 1914, empleando difracción de rayos X con cristales, proporcionó los elementos clave para alcanzar tal conocimiento. Posteriores desarrollos en este campo, que condujeron a la cristalografía macromolecular, se presentan aquí desde una perspectiva personal, relacionada con el contexto cultural de la España de la década de los 50. La experiencia del descubrimiento científico, durante mi desarrollo profesional, se integra en el desarrollo de la cristalografía macromolecular, desde las primeras proteínas (míoglobina y hemoglobina, hasta su madurez en 1971 que, con los posteriores descubrimientos, culmina con la determinación del la estructura del ribosoma. Asimismo, se explora el futuro de esta disciplina y se

  16. PEGylated chitosan grafted with polyamidoaminedendron as tumor-targeted magnetic resonance imaging contrast agent

    International Nuclear Information System (INIS)

    Guangyue Zu; Xiaoyan Tong; Yi Cao; Ye Kuang; Yajie Zhang; Min Liu; Renjun Pei

    2017-01-01

    Macromolecular contrast agents labeled with targeting ligands are now receiving growing interest in tumor-targeted magnetic resonance imaging. In this study, a macromolecular contrast agent based on PEGylated chitosan was synthesized and characterized, and its application as an MRI contrast agent was then demonstrated both in vitro and in vivo. First, the chitosan backbone was partially grafted with poly(ethylene glycol), which was used to improve the in vivo stability, followed by modifying with azide groups. Second, alkynyl-terminated PAMAM dendron modified with gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) was synthesized and conjugated onto the chitosan backbone through click chemistry. Finally, the obtained mCA was further functionalized with folic acid to improve the target specificity. The obtained FA labeled mCA exhibited higher relaxivity (9.53 mM"-"1.s"-"1) relative to Gd-DTPA (4.25 mM"-"1.s"-"1) and showed negligible toxicity as determined by the WST assay. In vivo MRI results suggested that a relatively high signal enhancement was observed in the tumor region, which made it a promising candidate for tumor-targeted MRI CA. (authors)

  17. Structure studies of macromolecular systems

    Czech Academy of Sciences Publication Activity Database

    Hašek, Jindřich; Dohnálek, Jan; Skálová, Tereza; Dušková, Jarmila; Kolenko, Petr

    2006-01-01

    Roč. 13, č. 3 (2006), s. 136 ISSN 1211-5894. [Czech and Slovak Crystallographic Colloquium. 22.06.2006-24.06.2006, Grenoble] R&D Projects: GA AV ČR IAA4050811; GA MŠk 1K05008 Keywords : structure * X-ray diffraction * synchrotron Subject RIV: CD - Macromolecular Chemistry http://www. xray .cz/ms/default.htm

  18. Case with high cervical intramedullary hemangioblastoma associated with arteriovenous fistula. CT with simultaneous intravenous and intrathecal injection of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takao; Shoji, Shin-ichi; Yanagisawa, Nobuo; Tada, Tsuyoshi; Kobayashi, Naoki

    1988-02-01

    A 34-year-old woman complained of right hemiparesis and pain in the right hand. Routine X-ray of the cervical portion failed to reveal abnormal findings. CT with intravenous contrast medium showed a large high-density mass in the spinal canal at the level of C2. Right vertebral angiography showed a hypervascular mass. With simultaneous intravenous and intrathecal injections of contrast medium, the tumor was shown as a moderately high-density area and the parenchyma of cord as a thin low-density area surrounding the tumor stain on CT. These CT appearances led to the final diagnosis of high cervical intramedullary hemangioblastoma associated with arteriovenous fistulae. Pathological findings are typical of hemangioblastoma. The usefulness of CT in detecting the localization of hypervascular spinal cord lesions is stressed. (Namekawa, K.).

  19. Contrast medium-induced nephropathy: Aspects on incidence ...

    African Journals Online (AJOL)

    Contrast media-induced nephropathy (CIN) is a well-known complication of radiological examinations employing iodine contrast media (I-CM). The rapid development and frequent use of coronary interventions and multi-channel detector computed tomography with concomitant administration of relatively large doses of ...

  20. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT - A pooled analysis of two randomized trials

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [University of Copenhagen, Department of Diagnostic Radiology, Copenhagen University Hospital Herlev, and Department of Diagnostic Sciences, Faculty of Health Sciences, Herlev (Denmark); Morcos, Sameh K. [University of Sheffield, Department of Diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom)

    2009-04-15

    The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients with glomerular filtration rate (GFR) <60 ml/min undergoing contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients with moderate-to-severe renal failure received a similar IV contrast dose (40 gI). Serum creatinine (SCr) was measured at screening, baseline and 48-72 {+-} 6 h after the MDCT examination. Primary CIN outcome was an increase in SCr {>=}0.5 mg/dl ({>=}44.2 {mu}mol/l) from baseline. The CIN rates were 2.3% in the total population, 0.6% when GFR >40 ml/min, 4.6% when GFR <40 ml/min and 7.8% in patients with GFR <30 ml/min. The incidence of CIN was significantly higher after iodixanol than after LOCM (seven patients, 4.7% following IOCM, no CIN cases following the LOCM; p = 0.007). Significant differences in favor of the LOCM were also observed in patients with GFR <40 ml/min and GFR <30 ml/min. Following the IV administration of nonionic contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM iopamidol and iomeprol, especially in high-risk patients. Differences in osmolality between these LOCM and iodixanol do not play a role in the genesis of CIN. (orig.)

  1. Atomic force microscopy imaging of macromolecular complexes.

    Science.gov (United States)

    Santos, Sergio; Billingsley, Daniel; Thomson, Neil

    2013-01-01

    This chapter reviews amplitude modulation (AM) AFM in air and its applications to high-resolution imaging and interpretation of macromolecular complexes. We discuss single DNA molecular imaging and DNA-protein interactions, such as those with topoisomerases and RNA polymerase. We show how relative humidity can have a major influence on resolution and contrast and how it can also affect conformational switching of supercoiled DNA. Four regimes of AFM tip-sample interaction in air are defined and described, and relate to water perturbation and/or intermittent mechanical contact of the tip with either the molecular sample or the surface. Precise control and understanding of the AFM operational parameters is shown to allow the user to switch between these different regimes: an interpretation of the origins of topographical contrast is given for each regime. Perpetual water contact is shown to lead to a high-resolution mode of operation, which we term SASS (small amplitude small set-point) imaging, and which maximizes resolution while greatly decreasing tip and sample wear and any noise due to perturbation of the surface water. Thus, this chapter provides sufficient information to reliably control the AFM in the AM AFM mode of operation in order to image both heterogeneous samples and single macromolecules including complexes, with high resolution and with reproducibility. A brief introduction to AFM, its versatility and applications to biology is also given while providing references to key work and general reviews in the field.

  2. Control of Macromolecular Architectures for Renewable Polymers: Case Studies

    Science.gov (United States)

    Tang, Chuanbing

    The development of sustainable polymers from nature biomass is growing, but facing fierce competition from existing petrochemical-based counterparts. Controlling macromolecular architectures to maximize the properties of renewable polymers is a desirable approach to gain advantages. Given the complexity of biomass, there needs special consideration other than traditional design. In the presentation, I will talk about a few case studies on how macromolecular architectures could tune the properties of sustainable bioplastics and elastomers from renewable biomass such as resin acids (natural rosin) and plant oils.

  3. Nonlinear image blending for dual-energy MDCT of the abdomen: can image quality be preserved if the contrast medium dose is reduced?

    Science.gov (United States)

    Mileto, Achille; Ramirez-Giraldo, Juan Carlos; Marin, Daniele; Alfaro-Cordoba, Marcela; Eusemann, Christian D; Scribano, Emanuele; Blandino, Alfredo; Mazziotti, Silvio; Ascenti, Giorgio

    2014-10-01

    The objective of this study was to compare the image quality of a dual-energy nonlinear image blending technique at reduced load of contrast medium with a simulated 120-kVp linear blending technique at a full dose during portal venous phase MDCT of the abdomen. Forty-five patients (25 men, 20 women; mean age, 65.6 ± 9.7 [SD] years; mean body weight, 74.9 ± 12.4 kg) underwent contrast-enhanced single-phase dual-energy CT of the abdomen by a random assignment to one of three different contrast medium (iomeprol 400) dose injection protocols: 1.3, 1.0, or 0.65 mL/kg of body weight. The contrast-to-noise ratio (CNR) and noise at the portal vein, liver, aorta, and kidney were compared among the different datasets using the ANOVA. Three readers qualitatively assessed all datasets in a blinded and independent fashion. Nonlinear blended images at a 25% reduced dose allowed a significant improvement in CNR (p < 0.05 for all comparisons), compared with simulated 120-kVp linear blended images at a full dose. No statistically significant difference existed in CNR and noise between the nonlinear blended images at a 50% reduced dose and the simulated 120-kVp linear blended images at a full dose. Nonlinear blended images at a 50% reduced dose were considered in all cases to have acceptable image quality. The dual-energy nonlinear image blending technique allows reducing the dose of contrast medium up to 50% during portal venous phase imaging of the abdomen while preserving image quality.

  4. Hypoxic tumor environments exhibit disrupted collagen I fibers and low macromolecular transport.

    Directory of Open Access Journals (Sweden)

    Samata M Kakkad

    Full Text Available Hypoxic tumor microenvironments result in an aggressive phenotype and resistance to therapy that lead to tumor progression, recurrence, and metastasis. While poor vascularization and the resultant inadequate drug delivery are known to contribute to drug resistance, the effect of hypoxia on molecular transport through the interstitium, and the role of the extracellular matrix (ECM in mediating this transport are unexplored. The dense mesh of fibers present in the ECM can especially influence the movement of macromolecules. Collagen 1 (Col1 fibers form a key component of the ECM in breast cancers. Here we characterized the influence of hypoxia on macromolecular transport in tumors, and the role of Col1 fibers in mediating this transport using an MDA-MB-231 breast cancer xenograft model engineered to express red fluorescent protein under hypoxia. Magnetic resonance imaging of macromolecular transport was combined with second harmonic generation microscopy of Col1 fibers. Hypoxic tumor regions displayed significantly decreased Col1 fiber density and volume, as well as significantly lower macromolecular draining and pooling rates, than normoxic regions. Regions adjacent to severely hypoxic areas revealed higher deposition of Col1 fibers and increased macromolecular transport. These data suggest that Col1 fibers may facilitate macromolecular transport in tumors, and their reduction in hypoxic regions may reduce this transport. Decreased macromolecular transport in hypoxic regions may also contribute to poor drug delivery and tumor recurrence in hypoxic regions. High Col1 fiber density observed around hypoxic regions may facilitate the escape of aggressive cancer cells from hypoxic regions.

  5. Macromolecular target prediction by self-organizing feature maps.

    Science.gov (United States)

    Schneider, Gisbert; Schneider, Petra

    2017-03-01

    Rational drug discovery would greatly benefit from a more nuanced appreciation of the activity of pharmacologically active compounds against a diverse panel of macromolecular targets. Already, computational target-prediction models assist medicinal chemists in library screening, de novo molecular design, optimization of active chemical agents, drug re-purposing, in the spotting of potential undesired off-target activities, and in the 'de-orphaning' of phenotypic screening hits. The self-organizing map (SOM) algorithm has been employed successfully for these and other purposes. Areas covered: The authors recapitulate contemporary artificial neural network methods for macromolecular target prediction, and present the basic SOM algorithm at a conceptual level. Specifically, they highlight consensus target-scoring by the employment of multiple SOMs, and discuss the opportunities and limitations of this technique. Expert opinion: Self-organizing feature maps represent a straightforward approach to ligand clustering and classification. Some of the appeal lies in their conceptual simplicity and broad applicability domain. Despite known algorithmic shortcomings, this computational target prediction concept has been proven to work in prospective settings with high success rates. It represents a prototypic technique for future advances in the in silico identification of the modes of action and macromolecular targets of bioactive molecules.

  6. Patient radiation dose during fluoroscopy testes with contrast medium

    International Nuclear Information System (INIS)

    Darsalih, Abir Abdelrady El noor

    2016-09-01

    The purpose of this study was to assess the patient radiation dose received in fluoroscopy examinations during contrast medium. The cumulative air kerma (Ck), kerma area product (KAP) and fluoroscopy time were measured for sixty ( male and female ) patients undergoing five fluoroscopy examinations KAP metre which was installed for the purpose of this study. The mean kerma area product were found to be 2.681, 5.1561, 9.85529. 5.7974 and 13.09 Gy.cm"2 for HSG, A.S and D.S, GI Track and sonogram tests, respectively. The obtained mean cumulative dose was were 6.31, 13.88, 24.61, 22.56 and 32.14 mGy for HSG, A.S, A.S and D.S , GI Track, respectively, the mean fluoroscopy time were. 0.18, 0.51,0.89,1.57 and 1.75 min, for HSG, A.S, A.S, and D.S, G1 Track and sonogram test respectively. Patient dose is mainly dependent on the patient size, procedure, equipment used exposure factor and user experience. As KV and mA were controlled by the AEC and it was found to be well calibrated, possible optimization could be achieved by radiologist by decreasing the exposure time if possible. (Author)

  7. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Oztoprak, I. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey)], E-mail: oztoprak@cumhuriyet.edu.tr; Guemues, C.; Oztoprak, B. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey); Engin, A. [Department of Infectious Diseases, Cumhuriyet University Faculty of Medicine, Sivas (Turkey)

    2007-12-15

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas.

  8. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    International Nuclear Information System (INIS)

    Oztoprak, I.; Guemues, C.; Oztoprak, B.; Engin, A.

    2007-01-01

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas

  9. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  10. Stochastic reaction-diffusion algorithms for macromolecular crowding

    Science.gov (United States)

    Sturrock, Marc

    2016-06-01

    Compartment-based (lattice-based) reaction-diffusion algorithms are often used for studying complex stochastic spatio-temporal processes inside cells. In this paper the influence of macromolecular crowding on stochastic reaction-diffusion simulations is investigated. Reaction-diffusion processes are considered on two different kinds of compartmental lattice, a cubic lattice and a hexagonal close packed lattice, and solved using two different algorithms, the stochastic simulation algorithm and the spatiocyte algorithm (Arjunan and Tomita 2010 Syst. Synth. Biol. 4, 35-53). Obstacles (modelling macromolecular crowding) are shown to have substantial effects on the mean squared displacement and average number of molecules in the domain but the nature of these effects is dependent on the choice of lattice, with the cubic lattice being more susceptible to the effects of the obstacles. Finally, improvements for both algorithms are presented.

  11. Ionic and non-ionic contrast media used for contrast-enhanced computed tomography in experimental pancreatitis

    International Nuclear Information System (INIS)

    Kivisaari, L.; Nuutinen, P.; Lehtola, A.; Saari, A.; Pitkaeranta, P.; Standertskjoeld-Nordenstam, C.G.; Lempinen, M.; Schroeder, T.; Helsinki Univ. Central Hospital

    1988-01-01

    Contrast enhancement of the pancreas was studied in pigs using dynamic computed tomography in experimental oedematous and haemorrhagic/necrotizing pancreatitis during the first two minutes after injection of an intravenous bolus of non-ionic contrast medium (iohexol). The prospects of separating the two forms of the disease, known to be possible with ionic contrast media, were tested with a non-ionic contrast medium. In the oedematous form, contrast enhancement after 5 hours of the disease was significantly higher than in the haemorrhagic/necrotizing form. Contrast enhancement after 30 hours of disease tended to vary with the severity of the disease, showing that the course of oedematous pancreatitis is dynamic. Intermediate forms occur and follow-up studies are needed during the disease. A non-ionic contrast medium proved as good for separating the two forms of the disease in the early phase as were ionic contrast media. In severely ill patients, non-ionic contrast media should therefore be used. (orig.)

  12. In situ macromolecular crystallography using microbeams.

    Science.gov (United States)

    Axford, Danny; Owen, Robin L; Aishima, Jun; Foadi, James; Morgan, Ann W; Robinson, James I; Nettleship, Joanne E; Owens, Raymond J; Moraes, Isabel; Fry, Elizabeth E; Grimes, Jonathan M; Harlos, Karl; Kotecha, Abhay; Ren, Jingshan; Sutton, Geoff; Walter, Thomas S; Stuart, David I; Evans, Gwyndaf

    2012-05-01

    Despite significant progress in high-throughput methods in macromolecular crystallography, the production of diffraction-quality crystals remains a major bottleneck. By recording diffraction in situ from crystals in their crystallization plates at room temperature, a number of problems associated with crystal handling and cryoprotection can be side-stepped. Using a dedicated goniometer installed on the microfocus macromolecular crystallography beamline I24 at Diamond Light Source, crystals have been studied in situ with an intense and flexible microfocus beam, allowing weakly diffracting samples to be assessed without a manual crystal-handling step but with good signal to noise, despite the background scatter from the plate. A number of case studies are reported: the structure solution of bovine enterovirus 2, crystallization screening of membrane proteins and complexes, and structure solution from crystallization hits produced via a high-throughput pipeline. These demonstrate the potential for in situ data collection and structure solution with microbeams. © 2012 International Union of Crystallography

  13. Effects of barium sulfate as a contrast medium to enterocutaneous fistulas

    International Nuclear Information System (INIS)

    Pelster, F.W.; Reichelt, S.; Arndt, M.; Eising, E.G.

    1989-01-01

    Fistulation following thoracic and epigastric interventions are conservatively treated, as a rule, because of the high rate of complications expected from reoperation. With properly functioning anastomotic transit, insufficiencies usually undergo spontaneous healing, within four to six weeks. Enterocutaneous fistulae developed in 29 of 271 patients with intrathoracic oesophagastric or oesophagojejunal anastomosis. Syringeal ramification into pleural or abdominal cavities were eliminated by means of an absorbable contrast medium, before barium sulphate was orally administered to all patients. Thoracic fistulae were closed after 21.8 days on average, while 20.3 days was the average period required for closure of epigastric fistulae. Barium sulphate was found to stimulate fistular tissue granulation, so that obliteration of the fistular system occurred much sooner, as compared to conservative treatment. The patient's quality of life can thus be improved, and hospitalisation can be shortened. Neither locally delimited nor systemic complications were observed in any of the cases described. (author)

  14. Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jia; Qu, Mingliang; Duan, Xinhui; Takahashi, Naoki; Kawashima, Akira; Leng, Shuai; McCollough, Cynthia H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2012-12-15

    To develop a dual-energy CT (DECT) method for differentiating uric acid (UA) from non-UA stones in the presence of iodinated contrast medium. Thirty UA and 45 non-UA stones were selected after infra-red spectroscopic analysis and independently placed in a 1.5-ml vial, which was filled first with saline and then with increasing concentrations of iodine. For each condition, tubes were put in a 35-cm water phantom and examined using a dual-source CT system at 100 and 140 kV. Virtual unenhanced images created from CT data sets of the stones in iodine-containing solutions provided position and volume information. This map was used to calculate a CT number ratio to differentiate stone type. A region-growing method was developed to improve the ability to differentiate between UA and non-UA stones with iodinated contrast medium. The sensitivity for detecting UA stones was 100 % for unenhanced images but fell to 18 % with 20 mgI/ml iodine solution and 0 % for higher concentrations. With region growing, the sensitivity for detecting UA stones was increased to 100 %, 82 %, 57 %, 50 % and 21 % for iodine solutions of 20, 40, 60, 80 and 100 mgI/ml. The region-growing method improves differentiation of UA from non-UA stones on contrast-enhanced DECT urograms. (orig.)

  15. Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chien-Ming; Chu, Sung-Yu; Hsu, Ming-Yi [Chang Gung University, Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital Linkou, College of Medicine, Taoyuan (China); Liao, Ying-Lan [National Tsing Hua University, Department of Biomedical Engineering and Environmental Sciences, Hsinchu (China); Tsai, Hui-Yu [Chang Gung University, Department of Medical Imaging and Radiological Sciences, College of Medicine, Taoyuan (China); Chang Gung University, Healthy Aging Research Center, Taoyuan (China); Chang Gung University, Department of Medical Imaging and Radiological Sciences, Taoyuan (China)

    2014-02-15

    To evaluate CT aortography at reduced tube voltage and contrast medium dose while maintaining image quality through iterative reconstruction (IR). The Institutional Review Board approved a prospective study of 48 patients who underwent follow-up CT aortography. We performed intra-individual comparisons of arterial phase images using 120 kVp (standard tube voltage) and 80 kVp (low tube voltage). Low-tube-voltage imaging was performed on a 320-detector CT with IR following injection of 40 ml of contrast medium. We assessed aortic attenuation, aortic attenuation gradient, image noise, contrast-to-noise ratio (CNR), volume CT dose index (CTDI{sub vol}), and figure of merit (FOM) of image noise and CNR. Two readers assessed images for diagnostic quality, image noise, and artefacts. The low-tube-voltage protocol showed 23-31 % higher mean aortic attenuation and image noise (both P < 0.01) than the standard-tube-voltage protocol, but no significant difference in the CNR and aortic attenuation gradients. The low-tube-voltage protocol showed a 48 % reduction in CTDI{sub vol} and an 80 % increase in FOM of CNR. Subjective diagnostic quality was similar for both protocols, but low-tube-voltage images showed greater image noise (P = 0.01). Application of IR to an 80-kVp CT aortography protocol allows radiation dose and contrast medium reduction without affecting image quality. (orig.)

  16. The Multi-center Evaluation of the Accuracy of the Contrast MEdium INduced Pd/Pa RaTiO in Predicting FFR (MEMENTO-FFR) Study.

    Science.gov (United States)

    Leone, Antonio Maria; Martin-Reyes, Roberto; Baptista, Sergio B; Amabile, Nicolas; Raposo, Luis; Franco Pelaez, Juan Antonio; Trani, Carlo; Cialdella, Pio; Basile, Eloisa; Zimbardo, Giuseppe; Burzotta, Francesco; Porto, Italo; Aurigemma, Cristina; Rebuzzi, Antonio G; Faustino, Mariana; Niccoli, Giampaolo; Abreu, Pedro F; Slama, Michel S; Spagnoli, Vincent; Telleria Arrieta, Miren; Amat Santos, Ignacio J; de la Torre Hernandez, Jose M; Lopez Palop, Ramon; Crea, Filippo

    2016-08-20

    Adenosine administration is needed for the achievement of maximal hyperaemia fractional flow reserve (FFR) assessment. The objective was to test the accuracy of Pd/Pa ratio registered during submaximal hyperaemia induced by non-ionic contrast medium (contrast FFR [cFFR]) in predicting FFR and comparing it to the performance of resting Pd/Pa in a collaborative registry of 926 patients enrolled in 10 hospitals from four European countries (Italy, Spain, France and Portugal). Resting Pd/Pa, cFFR and FFR were measured in 1,026 coronary stenoses functionally evaluated using commercially available pressure wires. cFFR was obtained after intracoronary injection of contrast medium, while FFR was measured after administration of adenosine. Resting Pd/Pa and cFFR were significantly higher than FFR (0.93±0.05 vs. 0.87±0.08 vs. 0.84±0.08, ptime and costs.

  17. Nanotoxic Profiling of Novel Iron Oxide Nanoparticles Functionalized with Perchloric Acid and SiPEG as a Radiographic Contrast Medium

    Directory of Open Access Journals (Sweden)

    Muhamad Idham Mohamed

    2015-01-01

    Full Text Available Emerging syntheses and findings of new metallic nanoparticles (MNPs have become an important aspect in various fields including diagnostic imaging. To date, iodine has been utilized as a radiographic contrast medium. However, the raise concern of iodine threats on iodine-intolerance patient has led to search of new contrast media with lower toxic level. In this animal modeling study, 14 nm iron oxide nanoparticles (IONPs with silane-polyethylene glycol (SiPEG and perchloric acid have been assessed for toxicity level as compared to conventional iodine. The nanotoxicity of IONPs was evaluated in liver biochemistry, reactive oxygen species production (ROS, lipid peroxidation mechanism, and ultrastructural evaluation using transmission electron microscope (TEM. The hematological analysis and liver function test (LFT revealed that most of the liver enzymes were significantly higher in iodine-administered group as compared to those in normal and IONPs groups P<0.05. ROS production assay and lipid peroxidation indicator, malondialdehyde (MDA, also showed significant reductions in comparison with iodine group P<0.05. TEM evaluation yielded the aberration of nucleus structure of iodine-administered group as compared to those in control and IONPs groups. This study has demonstrated the less toxic properties of IONPs and it may postulate that IONPs are safe to be applied as radiographic contrast medium.

  18. Role of hemolysis in potassium release by iodinated contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, K.; Nakamura, T.; Shimizu, Y. [Department of Radiology, Kyoto City Hospital (Japan)

    1999-09-01

    It has been demonstrated that an iodinated contrast medium (CM) causes release of potassium into blood vessel lumina, resulting in an increase in serum potassium. The purpose of the present study was to assess whether this potassium release is due to hemolysis. Fresh human blood was mixed in vitro with CM at a ratio of 10:2. Potassium release rates were determined, and serum haptoglobin and free hemoglobin were measured after 30 min of exposure to CM. To compare the potassium release curve between CM exposure and true hemolysis induced by distilled water, fresh human blood was also mixed with distilled water. The level of serum haptoglobin decreased due to hemodilution. Changes in haptoglobin were not correlated with potassium release rates. The serum free hemoglobin level did not increase significantly, and there was no correlation between changes in the free hemoglobin level and the rate of potassium release. Hemolysis caused by water occurred instantaneously, whereas potassium release caused by CM was a slow response, which was linearly correlated with exposure time. Potassium release from blood cannot be explained by hemolysis. (orig.) With 4 figs., 4 tabs., 3 refs.

  19. Intravenous contrast medium application in elderly patients - evaluation of Iopentol (Imagopaque trademark 300); Intravenoese Kontrastmittel-Applikation bei aelteren Patienten - Anwendungsbeobachtung von Iopentol (Imagopaque trademark 300)

    Energy Technology Data Exchange (ETDEWEB)

    Rathsmann, P.; Jacobs, G.F.; Mueller, R.D. [Zentrum fuer Klinische Radiologie, Kliniken Essen-Sued (Germany)

    2004-12-01

    Purpose: We examined the subjective compatibility of elderly patients who received the intravenous contrast medium Iopentol (Imagopaque trademark 300). In addition, objective data were acquired to show possible interactions between contrast media and organ systems in old patients. Methods and materials: A CT scan with intravenous application of contrast media was performed on 132 patients ranging in age from 75 to 96 years. The patients were questioned about their individual sensations. In addition, blood pressure, creatinine and CT-densitometry were acquired as objective date. Results: The patients' individual sensations and clinical data show a very low rate of complications. Mild allergic reactions were noticed in two patients. No severe anaphylactic reactions were encountered. Statistically significant changes in blood pressure before and after administration of the contrast medium were not observed. The serum creatinine concentration was unchanged after application of contrast media. For CT-densitometry, the patients were divided into two groups, one group with patients 75-84 years and the other group with patients 85-96 years of age. CT-densitometry showed no age-related differences. The protocol of contrast administration resulted in excellent opacification of the examined regions, only the liver did not enhance in some cases before the opacification of the portal vein. Conclusion: It is shown that old age alone is no reason to withhold contrast media containing iodine when performing CT. For the evaluation of the liver, however, the peculiarities of old age have to be taken into account and the interval between injection of the contrast medium and beginning of the spiral-CT has to be extended. (orig.)

  20. Iomeprol: results of clinical trials in children with a new nonionic contrast medium

    International Nuclear Information System (INIS)

    Gessel, R. van; Moeller, A.; Schmiedel, E.

    1994-01-01

    A total of 438 patients (1 day - 17 years) were enrolled in open-label phase III studies with Iomeprol in the most important radiologic, urologic, and cardiologic indications. Iomeprol was tested in five concentrations ranging from isotonic solutions of 150 mg iodine/ml up to 400 mg iodine/ml. Half of the patients were younger than 3 years. Apart from the mostly slight sensations of heat, pain, and taste, the following adverse events were observed independently of a causal relationship to the test compound: vomiting (1.8%), rise in blood pressure (1.8%), and restlessness (1.1%). The respective incidence of all other adverse events was below 1%. Iomeprol is a suitable and well-tolerated nonionic contrast medium for use in pediatric examinations. (orig./MG) [de

  1. Studies on the usefulness of negative contrast medium for CT-fatty emulsion-in diseases of the gastrointestinal tract

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Tsuneo; Kameda, Kyoko; Tanaka, Koji; Nishimura, Shigeru; Higashide, Toshiaki [Osaka Police Hospital (Japan)

    1983-09-01

    Investigation was made on the usefulness of negative contrast medium for CT-fatty emulsion-, which is applicable to the whole area of the gastrointestinal tract, in diagnoses of diseases of the stomach, pancreas, colon and the organs adjacent to the three. After the administration of the drug, CT was performed and the thickness of the walls were measured for the normal upper gastrointestinal tract in 50 patients and for the normal colon in 25. The normal gastric walls did not exceed 5 mm and the walls of the colon measured about 2.1 mm. Gastric tumors were projected at 80.4%. Especially, the drug was useful for the early diagnosis of schirrus. The pancreas was more clearly projected in 88.4% of the patients. The reconstruction method using the present drug was useful for the investigation of the relationship between the two organs, the stomach and the duodenum, and the pancreas. When CT was performed on a patient laying this right side on the bed, invasion of pancreatic cancer and gastric antrum cancer into the circumferntial organs could be diagnosed. The drug was useful for the identification of tumors in the colon and intrapelvic lesions. The medium was also given to four patients with colitis ulcerosa and the obtained findings on the wall features were same as those obtained by barium enema. The present drug was little associated with side effects and is considered to be an excellent negative contrast medium for all the gastrointestinal tracts.

  2. Does MRI with oral contrast medium allow single-study depiction of inflammatory bowel disease enteritis and colitis?

    International Nuclear Information System (INIS)

    Cronin, Carmel G.; Lohan, Derek G.; Browne, Ann Michelle; Roche, Clare; Murphy, Joseph M.

    2010-01-01

    To assess the feasibility and utility of magnetic resonance (MR) imaging of the bowel in concurrent small- and large-bowel evaluation for the presence of inflammatory bowel disease (IBD). Over a 5-year period, 62 MR examinations performed on 53 patients demonstrated evidence of IBD. Sixteen of these 53 (30.1%) patients had imaging findings of colonic disease and underwent 19 formal MR small bowel examinations. These were further evaluated for bowel distention and image quality. The sensitivity and specificity of the technique compared with colonoscopy as the 'gold standard' was evaluated. Simultaneous imaging of the colon is feasible at MR small bowel follow-through with moderate-to-excellent colonic visibility and colon distention obtained when the contrast medium is present in the colon at the time of image acquisition. MR imaging had a sensitivity of 80% (0.56-0.93), specificity of 100% (0.77-1.00), positive predictive value (PPV) of 1 and a negative predictive value (NPV) of 0.8 for the identification of colitis (based on available concurrent correlation of 38/62 examinations with colonoscopy). Small and large bowel MR imaging with orally consumed contrast medium represents a promising, feasible, non-invasive, non-radiating single mode of assessment of the entire gastrointestinal tract, performed at a single sitting. (orig.)

  3. In situ macromolecular crystallography using microbeams

    International Nuclear Information System (INIS)

    Axford, Danny; Owen, Robin L.; Aishima, Jun; Foadi, James; Morgan, Ann W.; Robinson, James I.; Nettleship, Joanne E.; Owens, Raymond J.; Moraes, Isabel; Fry, Elizabeth E.; Grimes, Jonathan M.; Harlos, Karl; Kotecha, Abhay; Ren, Jingshan; Sutton, Geoff; Walter, Thomas S.; Stuart, David I.; Evans, Gwyndaf

    2012-01-01

    A sample environment for mounting crystallization trays has been developed on the microfocus beamline I24 at Diamond Light Source. The technical developments and several case studies are described. Despite significant progress in high-throughput methods in macromolecular crystallography, the production of diffraction-quality crystals remains a major bottleneck. By recording diffraction in situ from crystals in their crystallization plates at room temperature, a number of problems associated with crystal handling and cryoprotection can be side-stepped. Using a dedicated goniometer installed on the microfocus macromolecular crystallography beamline I24 at Diamond Light Source, crystals have been studied in situ with an intense and flexible microfocus beam, allowing weakly diffracting samples to be assessed without a manual crystal-handling step but with good signal to noise, despite the background scatter from the plate. A number of case studies are reported: the structure solution of bovine enterovirus 2, crystallization screening of membrane proteins and complexes, and structure solution from crystallization hits produced via a high-throughput pipeline. These demonstrate the potential for in situ data collection and structure solution with microbeams

  4. In situ macromolecular crystallography using microbeams

    Energy Technology Data Exchange (ETDEWEB)

    Axford, Danny; Owen, Robin L.; Aishima, Jun [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); Foadi, James [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); Imperial College, London SW7 2AZ (United Kingdom); Morgan, Ann W.; Robinson, James I. [University of Leeds, Leeds LS9 7FT (United Kingdom); Nettleship, Joanne E.; Owens, Raymond J. [Research Complex at Harwell, Rutherford Appleton Laboratory R92, Didcot, Oxfordshire OX11 0DE (United Kingdom); Moraes, Isabel [Imperial College, London SW7 2AZ (United Kingdom); Fry, Elizabeth E.; Grimes, Jonathan M.; Harlos, Karl; Kotecha, Abhay; Ren, Jingshan; Sutton, Geoff; Walter, Thomas S. [University of Oxford, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Stuart, David I. [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); University of Oxford, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Evans, Gwyndaf, E-mail: gwyndaf.evans@diamond.ac.uk [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom)

    2012-04-17

    A sample environment for mounting crystallization trays has been developed on the microfocus beamline I24 at Diamond Light Source. The technical developments and several case studies are described. Despite significant progress in high-throughput methods in macromolecular crystallography, the production of diffraction-quality crystals remains a major bottleneck. By recording diffraction in situ from crystals in their crystallization plates at room temperature, a number of problems associated with crystal handling and cryoprotection can be side-stepped. Using a dedicated goniometer installed on the microfocus macromolecular crystallography beamline I24 at Diamond Light Source, crystals have been studied in situ with an intense and flexible microfocus beam, allowing weakly diffracting samples to be assessed without a manual crystal-handling step but with good signal to noise, despite the background scatter from the plate. A number of case studies are reported: the structure solution of bovine enterovirus 2, crystallization screening of membrane proteins and complexes, and structure solution from crystallization hits produced via a high-throughput pipeline. These demonstrate the potential for in situ data collection and structure solution with microbeams.

  5. In vitro experiments for the development of a high density (HD) barium sulfate contrast medium

    International Nuclear Information System (INIS)

    Klein, J.

    1986-01-01

    In vitro experiments with the high-density (HD) barium meal Falibaryt HD are described. Several charges of BaSO 4 were tested together with certain additives influencing dispersion, stability of the suspension, flowability, surface tension etc. Particle size spectra were measured by the manufacturer, VEB Fahlberg-List. With a simple PVC test plate containing several grooves simulating small details (areae gastricae) the diagnostic capabilities of the HD contrast medium were evaluated in an in vitro test. The developed barium meal Falibaryt HD is in its physical and chemical parameters comparable with Prontobario-HD, one of the best HD barium meals. (author)

  6. An acoustic on-chip goniometer for room temperature macromolecular crystallography.

    Science.gov (United States)

    Burton, C G; Axford, D; Edwards, A M J; Gildea, R J; Morris, R H; Newton, M I; Orville, A M; Prince, M; Topham, P D; Docker, P T

    2017-12-05

    This paper describes the design, development and successful use of an on-chip goniometer for room-temperature macromolecular crystallography via acoustically induced rotations. We present for the first time a low cost, rate-tunable, acoustic actuator for gradual in-fluid sample reorientation about varying axes and its utilisation for protein structure determination on a synchrotron beamline. The device enables the efficient collection of diffraction data via a rotation method from a sample within a surface confined droplet. This method facilitates efficient macromolecular structural data acquisition in fluid environments for dynamical studies.

  7. Experimental and clinical studies of non-ionic isoosmolality contrast medium (iohexol 140), 2

    International Nuclear Information System (INIS)

    Tajima, Natsuki

    1986-01-01

    Based upon the results of fundamental investigation by the author, that non-ionic isoosmolality contrast medium, iohexol 140 mgI/ml, has almost no adverse effect on the shape of erythrocyte. Intraarterial digital subtraction angiography (IADSA) was performed with this agent in clinical practice. A total number of 344 injections was performed in 100 cases, and angiographic opacifications, subjective reactions and hemodynamic alterations were analysed. The contrast opacifications were excellent or good except five injections on which angiographies were afflicted by misregistration artifact. As for adverse reactions there were only 14 cases who complained mild heat sensations, whereas no pain was experienced. The intensity of local heat sensation at peripheral arteriographies was statistically milder than that caused by diatrizoate 292 mgI/ml (p < 0.001) and iohexol 300 mgI/ml (p < 0.001). The continuous monitorings of femoral blood pressure and electrocardiogram following 16 cases of thoracic aortography, 17 abdominal aortographies and 80 peripheral arteriographies revealed that iohexol 140 mgI/ml caused significantly less effects on decrease of both systolic and diastolic blood pressure and increase of heart rate. Thus it was concluded that iohexol 140 mgI/ml was well suited for IADSA as it caused no pain, good opacification quality and minimum hemodynamic effects. (author)

  8. Radical copolymerization in homogenous medium and emulsion system monomers acrylonitrile/styrene

    Directory of Open Access Journals (Sweden)

    Boussehel H.

    2013-09-01

    Full Text Available This study examines the radical copolymerization in homogeneous and emulsion of the monomer system acrylonitrile/styrene. These copolymers are of great interest to the plastics industry, because they combine the good mechanical properties and implementation provided by the styrene units in the very high solvent resistance and extreme gas impermeability provided by the acrylonitrile units. The properties of a copolymer are directly related to its composition and distribution of monomer units in its macromolecular chains. Based on the reports of the couple reactivity's of monomers (AN/S found in the literature, the objective of the work is to provide theoretical simulation (by analytical and numerical integration of the equation of copolymerization: The kinetics of the reaction copolymerization of AN/S in a homogeneous medium and emulsion (drift composition, azeotropic and the microstructure (distribution of monomer sequences and the glass transition property of the macromolecular chains instant formed throughout the copolymerization reaction.

  9. Body surface area adapted iopromide 300 mg/ml versus 370 mg/ml contrast medium injection protocol: Influence on quantitative and clinical assessment in combined PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Verburg, Frederik A., E-mail: fverburg@ukaachen.de [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Apitzsch, Jonas [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Lensing, Carina [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Kuhl, Christiane K. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Pietsch, Hubertus [Bayer Pharma AG, Müllerstrasse 178, 13353 Berlin (Germany); Mottaghy, Felix M. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Behrendt, Florian F. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany)

    2013-12-01

    Purpose: To investigate the quantitative and qualitative differences between combined positron emission tomography and computed X-ray tomography (PET/CT) enhanced with contrast medium with either an iodine concentration 300 mg/ml or 370 mg/ml. Materials and methods: 120 consecutive patients scheduled for F-18-Fluorodeoxyglucose (FDG) PET/CT were included. The first (second) 60 patients received contrast medium with 300 (370) mg iodine/ml. Intravenous injection protocols were adapted for an identical iodine delivery rate (1.3 mg/s) and body surface area (BSA) adapted iodine dose (22.26 g I/m{sup 2}). Maximum and mean standardized uptake values (SUV{sub max}; SUV{sub mean}) and contrast enhancement (HU) were determined in the ascending aorta, the abdominal aorta, the inferior vena cava, the portal vein, the liver and the right kidney in the venous contrast medium phase. PET data were evaluated visually for the presence of malignancy and image quality. Results: Both media caused significantly higher values for HU, SUV{sub mean} and SUV{sub max} for the enhanced PET/CT than the non-enhanced one (all p < 0.01). There were no significant differences in the degree of increase of HU, SUV{sub mean} and SUV{sub max} between the two contrast media at any anatomic site (all p > 0.05). Visual evaluation of lesions showed no differences between contrast and non-contrast PET/CT or between the two different contrast media (p = 0.77). Conclusion: When using a constant iodine delivery rate and total iodine dose in a BSA adapted injection protocol, there are no quantitative or qualitative differences in either CT or PET between contrast media with an iodine concentration of 300 mg/ml and 370 mg/ml, respectively.

  10. Gaussian-Based Smooth Dielectric Function: A Surface-Free Approach for Modeling Macromolecular Binding in Solvents

    Directory of Open Access Journals (Sweden)

    Arghya Chakravorty

    2018-03-01

    Full Text Available Conventional modeling techniques to model macromolecular solvation and its effect on binding in the framework of Poisson-Boltzmann based implicit solvent models make use of a geometrically defined surface to depict the separation of macromolecular interior (low dielectric constant from the solvent phase (high dielectric constant. Though this simplification saves time and computational resources without significantly compromising the accuracy of free energy calculations, it bypasses some of the key physio-chemical properties of the solute-solvent interface, e.g., the altered flexibility of water molecules and that of side chains at the interface, which results in dielectric properties different from both bulk water and macromolecular interior, respectively. Here we present a Gaussian-based smooth dielectric model, an inhomogeneous dielectric distribution model that mimics the effect of macromolecular flexibility and captures the altered properties of surface bound water molecules. Thus, the model delivers a smooth transition of dielectric properties from the macromolecular interior to the solvent phase, eliminating any unphysical surface separating the two phases. Using various examples of macromolecular binding, we demonstrate its utility and illustrate the comparison with the conventional 2-dielectric model. We also showcase some additional abilities of this model, viz. to account for the effect of electrolytes in the solution and to render the distribution profile of water across a lipid membrane.

  11. Dry preparation for virtual CT colonography with fecal tagging using water-soluble contrast medium: initial results

    International Nuclear Information System (INIS)

    Bielen, Didier; Thomeer, Maarten; Vanbeckevoort, Dirk; Marchal, Guy; Kiss, Gabriel; Maes, Frederik; Rutgeerts, Paul

    2003-01-01

    The purpose of this study was to evaluate the feasibility of a dry bowel preparation, i.e. without laxative fluids, for virtual CT colonography (VCTC), and its impact on patient acceptance compared with conventional colonoscopy (CC). A randomly chosen patient population scheduled for CC (n=11) was first submitted to VCTC after a dry preparation, consisting of low-residue meals combined with a small amount of a iodinated water-soluble contrast medium during each meal 3 days before VCTC. In different colon segments and between different persons, the degree of tagging in VCTC was evaluated and graded. Patient acceptance and future preference were assessed for both preparations as well as for both investigations. The mixing of the contrast with the intestinal content results in contrast impregnated stool, the tagged feces. The degree of fecal tagging was good in the majority of the patients and the colonic segments, especially in the descending colon and sigmoid. Furthermore, patient acceptance and preference were clearly in favour of VCTC compared with CC merely because of the non-invasiveness of the dry preparation. Dry bowel preparation and VCTC is a promising approach towards a patient-friendly colon cancer-screening setup. (orig.)

  12. A public database of macromolecular diffraction experiments.

    Science.gov (United States)

    Grabowski, Marek; Langner, Karol M; Cymborowski, Marcin; Porebski, Przemyslaw J; Sroka, Piotr; Zheng, Heping; Cooper, David R; Zimmerman, Matthew D; Elsliger, Marc André; Burley, Stephen K; Minor, Wladek

    2016-11-01

    The low reproducibility of published experimental results in many scientific disciplines has recently garnered negative attention in scientific journals and the general media. Public transparency, including the availability of `raw' experimental data, will help to address growing concerns regarding scientific integrity. Macromolecular X-ray crystallography has led the way in requiring the public dissemination of atomic coordinates and a wealth of experimental data, making the field one of the most reproducible in the biological sciences. However, there remains no mandate for public disclosure of the original diffraction data. The Integrated Resource for Reproducibility in Macromolecular Crystallography (IRRMC) has been developed to archive raw data from diffraction experiments and, equally importantly, to provide related metadata. Currently, the database of our resource contains data from 2920 macromolecular diffraction experiments (5767 data sets), accounting for around 3% of all depositions in the Protein Data Bank (PDB), with their corresponding partially curated metadata. IRRMC utilizes distributed storage implemented using a federated architecture of many independent storage servers, which provides both scalability and sustainability. The resource, which is accessible via the web portal at http://www.proteindiffraction.org, can be searched using various criteria. All data are available for unrestricted access and download. The resource serves as a proof of concept and demonstrates the feasibility of archiving raw diffraction data and associated metadata from X-ray crystallographic studies of biological macromolecules. The goal is to expand this resource and include data sets that failed to yield X-ray structures in order to facilitate collaborative efforts that will improve protein structure-determination methods and to ensure the availability of `orphan' data left behind for various reasons by individual investigators and/or extinct structural genomics

  13. Macromolecular crowding-assisted fabrication of liquid-crystalline imprinted polymers.

    Science.gov (United States)

    Zhang, Chen; Zhang, Jing; Huang, Yan-Ping; Liu, Zhao-Sheng

    2015-04-01

    A macromolecular crowding-assisted liquid-crystalline molecularly imprinted monolith (LC-MIM) was prepared successfully for the first time. The imprinted stationary phase was synthesized with polymethyl methacrylate (PMMA) or polystyrene (PS) as the crowding agent, 4-cyanophenyl dicyclohexyl propylene (CPCE) as the liquid-crystal monomer, and hydroquinidine as the pseudo-template for the chiral separation of cinchona alkaloids in HPLC. A low level of cross-linker (26%) has been found to be sufficient to achieve molecular recognition on the crowding-assisted LC-MIM due to the physical cross-linking of mesogenic groups in place of chemical cross-linking, and baseline separation of quinidine and quinine could be achieved with good resolution (R(s) = 2.96), selectivity factor (α = 2.16), and column efficiency (N = 2650 plates/m). In contrast, the LC-MIM prepared without crowding agents displayed the smallest diastereoselectivity (α = 1.90), while the crowding-assisted MIM with high level of cross-linker (80%) obtained the greatest selectivity factor (α = 7.65), but the lowest column efficiency (N = 177 plates/m).

  14. Magnesium sulfate as an oral contrast medium in magnetic resonance imaging of the small intestine.

    Science.gov (United States)

    Shi, Hao; Liu, Cun; Ding, Hong Yu; Li, Chun Wei

    2012-03-01

    To explore the use of magnesium sulfate (MgSO4) as an oral contrast medium (CM) in MRI of the small intestine. By comparing MgSO4 SNRs at different concentrations, we determined that 2.5% MgSO4 is the ideal concentration for small bowel MRI. Twenty volunteers underwent MRI after drinking 2.5% MgSO4. Thirty-one patients with clinical suspicion of small intestinal pathology underwent both MRI and the air-barium contrast examination. The patient's tolerance, side effects and complications were noted. 2.5% MgSO4 can decrease the absorption of water and fully fill the enteric cavity, thereby increasing the contrast between the intestinal wall and lumen and facilitating radiographic examination of the small bowel. The mean diameter of the small intestine was 19.8±1.21 mm in the 20 volunteers consuming 2.5% MgSO4 and 12.7±0.84 mm in the 20 volunteers given water. There was a significant difference (P0.05) in side effects between MgSO4 and water groups. Small intestinal MRI was successfully performed in all 31 patients, who were also examined by the double contrast barium, which gave almost identical diagnoses to MRI in all cases except for 1 patient with small intestinal hemorrhage. MRI with 2.5% MgSO4 can demonstrate intestinal abnormalities. Therefore, 2.5% MgSO4 solution is an ideal oral CM for small bowel MRI. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  15. Macromolecular contrast media. A new approach for characterising breast tumors with MR-mammography; Makromolekulare Kontrastmittel fuer die MR-Mammographie. Ein neuer Ansatz fuer die Charakterisierung von Mammatumoren

    Energy Technology Data Exchange (ETDEWEB)

    Daldrup, H.E. [Contrast Media Lab., Dept. of Radiology, California Univ., San Francisco, CA (United States)]|[Muenster Univ. (Germany). Inst. fuer Klinische Radiologie; Roberts, T.P.L.; Roberts, H.C. [Contrast Media Lab., Dept. of Radiology, California Univ., San Francisco, CA (United States)]|[Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Muehler, A. [Contrast Media Lab., Dept. of Radiology, California Univ., San Francisco, CA (United States)]|[Berlex Laboratories, Wayne, NJ (United States); Gossmann, A. [Contrast Media Lab., Dept. of Radiology, California Univ., San Francisco, CA (United States)]|[Koeln Univ. (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Wendland, M.; Brasch, R.C. [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie; Rosenau, W. [California Univ., San Francisco, CA (United States). Dept. of Pathology

    1997-09-01

    The value of macromolecular contrast agents (MMCM) for the characterization of benign and malignant breast tumors will be demonstrated in this review. Animal studies suggest a high potential of MMCM to increase the specificity of MR-mammography. The concept of tumor differentiation is based on the pathological hyperpermeability of microvessels in malignant tumors. MMCM show a leak into the interstitium of carcinomas, whereas they are confined to the intravascular space in benign tumors. Capabilities and limitations of the MMCM-prototype. Albumin-Gd-DTPA, for breast tumor characterization will be summarized and compared to the standard low molecular weight contrast agent Gd-DTPA. Initial experience with new MMCM, such as Dendrimers, Gd-DTPA-Polylysine and MS-325 will be outlined. The potential of `blood-pool`-iron oxides, such as AMI-227 for the evaluation of tumor microvascular permeabilities will be discussed. (orig.) [Deutsch] Diese Uebersicht stellt den Stellenwert makromolekularer Kontrastmittel (MMKM) fuer die MR-tomographische Charakterisierung von benignen und malignen Mammatumoren dar. Aufgrund experimenteller Studien lassen MMKM eine signifikante Verbesserung der Spezifitaet der dynamischen kontrastmittelunterstuetzten MR-Mammographie erwarten. Das differentialdiagnostische Konzept beruht auf der pathologischen Hyperpermeabilitaet von Kapillaren in Karzinomen, die einen MMKM-Austritt in das Tumorinterstitium bedingt, waehrend die intakten Kapillaren benigner Tumoren nicht permeabel fuer MMKM sind. Diagnostische Moeglichkeiten und Grenzen des MMKM-Prototyps, Albumin-Gd-DTPA (92 kD), werden dargestellt und mit dem niedermolekularen Standard-Kontrastmittel Gd-DTPA (500 D) verglichen. Erste Erfahrungen mit neuen, fuer die klinische Anwendung optimierten MMKM-Praeparaten, wie das Kaskadenpolymer, Gd-DTPA-Polylysine und das MS-325 werden vorgestellt. Das Potential von Blood-pool-Eisenoxidpraeparaten, z.B. AMI-227, fuer die Bestimmung von

  16. Patient safety and adverse events in contrast medium examinations

    International Nuclear Information System (INIS)

    Enge, I.; Edgren, J.

    1989-01-01

    This volume contains six contributions dealing with the properties, safety and economic aspects (lower risks but higher costs of new low-osmonality contrast media compared to the older high-osmonality, ionic ones) of contrast media used in radiology, and risks involved in procedures for administering of radiologic contrast media. (H.W.). refs.; figs.; tabs

  17. Macromolecular Networks Containing Fluorinated Cyclic Moieties

    Science.gov (United States)

    2015-12-12

    Briefing Charts 3. DATES COVERED (From - To) 17 Nov 2015 – 12 Dec 2015 4. TITLE AND SUBTITLE Macromolecular Networks Containing Fluorinated Cyclic... FLUORINATED CYCLIC MOIETIES 12 December 2015 Andrew J. Guenthner,1 Scott T. Iacono,2 Cynthia A. Corley,2 Christopher M. Sahagun,3 Kevin R. Lamison,4...Reinforcements Good Flame, Smoke, & Toxicity Characteristics Low Water Uptake with Near Zero Coefficient of Hygroscopic Expansion ∆ DISTRIBUTION A

  18. Design and application of a C++ macromolecular class library.

    Science.gov (United States)

    Chang, W; Shindyalov, I N; Pu, C; Bourne, P E

    1994-01-01

    PDBlib is an extensible object oriented class library written in C++ for representing the 3-dimensional structure of biological macromolecules. PDBlib forms the kernel of a larger software framework being developed for assiting in knowledge discovery from macromolecular structure data. The software design strategy used by PDBlib, how the library may be used and several prototype applications that use the library are summarized. PDBlib represents the structural features of proteins, DNA, RNA, and complexes thereof, at a level of detail on a par with that which can be parsed from a Protein Data Bank (PDB) entry. However, the memory resident representation of the macromolecule is independent of the PDB entry and can be obtained from other back-end data sources, for example, existing relational databases and our own object oriented database (OOPDB) built on top of the commercial object oriented database, ObjectStore. At the front-end are several prototype applications that use the library: Macromolecular Query Language (MMQL) is based on a separate class library (MMQLlib) for building complex queries pertaining to macromolecular structure; PDBtool is an interactive structure verification tool; and PDBview, is a structure rendering tool used either as a standalone tool or as part of another application. Each of these software components are described. All software is available via anonymous ftp from cuhhca.hhmi.columbia.edu.

  19. Role of medium heterogeneity and viscosity contrast in miscible flow regimes and mixing zone growth: A computational pore-scale approach

    Science.gov (United States)

    Afshari, Saied; Hejazi, S. Hossein; Kantzas, Apostolos

    2018-05-01

    Miscible displacement of fluids in porous media is often characterized by the scaling of the mixing zone length with displacement time. Depending on the viscosity contrast of fluids, the scaling law varies between the square root relationship, a sign for dispersive transport regime during stable displacement, and the linear relationship, which represents the viscous fingering regime during an unstable displacement. The presence of heterogeneities in a porous medium significantly affects the scaling behavior of the mixing length as it interacts with the viscosity contrast to control the mixing of fluids in the pore space. In this study, the dynamics of the flow and transport during both unit and adverse viscosity ratio miscible displacements are investigated in heterogeneous packings of circular grains using pore-scale numerical simulations. The pore-scale heterogeneity level is characterized by the variations of the grain diameter and velocity field. The growth of mixing length is employed to identify the nature of the miscible transport regime at different viscosity ratios and heterogeneity levels. It is shown that as the viscosity ratio increases to higher adverse values, the scaling law of mixing length gradually shifts from dispersive to fingering nature up to a certain viscosity ratio and remains almost the same afterwards. In heterogeneous media, the mixing length scaling law is observed to be generally governed by the variations of the velocity field rather than the grain size. Furthermore, the normalization of mixing length temporal plots with respect to the governing parameters of viscosity ratio, heterogeneity, medium length, and medium aspect ratio is performed. The results indicate that mixing length scales exponentially with log-viscosity ratio and grain size standard deviation while the impact of aspect ratio is insignificant. For stable flows, mixing length scales with the square root of medium length, whereas it changes linearly with length during

  20. Contrast media on abdominal computed tomography

    International Nuclear Information System (INIS)

    Skalpe, I.O.; Oestensen, H.M.

    1984-01-01

    Abdominal computed tomography was performed in 55 patients before and after intravenous injection of 60 ml of a non-ionic (iohexol) or an ionic (metrizoate) contrast medium. The adverse effects were recorded and a series of measurements of attenuation values before and after the contrast medium injection was performed in the aorta and in hepatic and renal parenchyma. Only minor adverse effects were seen with both contrast media, but iohexol was clearly better tolerated than metrizoate. No difference in the enhancement properties was found between the two contrast media. (orig.)

  1. Principles and Overview of Sampling Methods for Modeling Macromolecular Structure and Dynamics.

    Science.gov (United States)

    Maximova, Tatiana; Moffatt, Ryan; Ma, Buyong; Nussinov, Ruth; Shehu, Amarda

    2016-04-01

    Investigation of macromolecular structure and dynamics is fundamental to understanding how macromolecules carry out their functions in the cell. Significant advances have been made toward this end in silico, with a growing number of computational methods proposed yearly to study and simulate various aspects of macromolecular structure and dynamics. This review aims to provide an overview of recent advances, focusing primarily on methods proposed for exploring the structure space of macromolecules in isolation and in assemblies for the purpose of characterizing equilibrium structure and dynamics. In addition to surveying recent applications that showcase current capabilities of computational methods, this review highlights state-of-the-art algorithmic techniques proposed to overcome challenges posed in silico by the disparate spatial and time scales accessed by dynamic macromolecules. This review is not meant to be exhaustive, as such an endeavor is impossible, but rather aims to balance breadth and depth of strategies for modeling macromolecular structure and dynamics for a broad audience of novices and experts.

  2. Outrunning free radicals in room-temperature macromolecular crystallography

    International Nuclear Information System (INIS)

    Owen, Robin L.; Axford, Danny; Nettleship, Joanne E.; Owens, Raymond J.; Robinson, James I.; Morgan, Ann W.; Doré, Andrew S.; Lebon, Guillaume; Tate, Christopher G.; Fry, Elizabeth E.; Ren, Jingshan; Stuart, David I.; Evans, Gwyndaf

    2012-01-01

    A systematic increase in lifetime is observed in room-temperature protein and virus crystals through the use of reduced exposure times and a fast detector. A significant increase in the lifetime of room-temperature macromolecular crystals is reported through the use of a high-brilliance X-ray beam, reduced exposure times and a fast-readout detector. This is attributed to the ability to collect diffraction data before hydroxyl radicals can propagate through the crystal, fatally disrupting the lattice. Hydroxyl radicals are shown to be trapped in amorphous solutions at 100 K. The trend in crystal lifetime was observed in crystals of a soluble protein (immunoglobulin γ Fc receptor IIIa), a virus (bovine enterovirus serotype 2) and a membrane protein (human A 2A adenosine G-protein coupled receptor). The observation of a similar effect in all three systems provides clear evidence for a common optimal strategy for room-temperature data collection and will inform the design of future synchrotron beamlines and detectors for macromolecular crystallography

  3. Outrunning free radicals in room-temperature macromolecular crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Owen, Robin L., E-mail: robin.owen@diamond.ac.uk; Axford, Danny [Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 0DE (United Kingdom); Nettleship, Joanne E.; Owens, Raymond J. [Rutherford Appleton Laboratory, Didcot OX11 0FA (United Kingdom); The Henry Wellcome Building for Genomic Medicine, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Robinson, James I.; Morgan, Ann W. [University of Leeds, Leeds LS9 7FT (United Kingdom); Doré, Andrew S. [Heptares Therapeutics Ltd, BioPark, Welwyn Garden City AL7 3AX (United Kingdom); Lebon, Guillaume; Tate, Christopher G. [MRC Laboratory of Molecular Biology, Hills Road, Cambridge CB2 0QH (United Kingdom); Fry, Elizabeth E.; Ren, Jingshan [The Henry Wellcome Building for Genomic Medicine, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Stuart, David I. [Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 0DE (United Kingdom); The Henry Wellcome Building for Genomic Medicine, Roosevelt Drive, Oxford OX3 7BN (United Kingdom); Evans, Gwyndaf [Diamond Light Source, Harwell Science and Innovation Campus, Didcot OX11 0DE (United Kingdom)

    2012-06-15

    A systematic increase in lifetime is observed in room-temperature protein and virus crystals through the use of reduced exposure times and a fast detector. A significant increase in the lifetime of room-temperature macromolecular crystals is reported through the use of a high-brilliance X-ray beam, reduced exposure times and a fast-readout detector. This is attributed to the ability to collect diffraction data before hydroxyl radicals can propagate through the crystal, fatally disrupting the lattice. Hydroxyl radicals are shown to be trapped in amorphous solutions at 100 K. The trend in crystal lifetime was observed in crystals of a soluble protein (immunoglobulin γ Fc receptor IIIa), a virus (bovine enterovirus serotype 2) and a membrane protein (human A{sub 2A} adenosine G-protein coupled receptor). The observation of a similar effect in all three systems provides clear evidence for a common optimal strategy for room-temperature data collection and will inform the design of future synchrotron beamlines and detectors for macromolecular crystallography.

  4. Macromolecular diffusion in crowded media beyond the hard-sphere model.

    Science.gov (United States)

    Blanco, Pablo M; Garcés, Josep Lluís; Madurga, Sergio; Mas, Francesc

    2018-04-25

    The effect of macromolecular crowding on diffusion beyond the hard-core sphere model is studied. A new coarse-grained model is presented, the Chain Entanglement Softened Potential (CESP) model, which takes into account the macromolecular flexibility and chain entanglement. The CESP model uses a shoulder-shaped interaction potential that is implemented in the Brownian Dynamics (BD) computations. The interaction potential contains only one parameter associated with the chain entanglement energetic cost (Ur). The hydrodynamic interactions are included in the BD computations via Tokuyama mean-field equations. The model is used to analyze the diffusion of a streptavidin protein among different sized dextran obstacles. For this system, Ur is obtained by fitting the streptavidin experimental long-time diffusion coefficient Dlongversus the macromolecular concentration for D50 (indicating their molecular weight in kg mol-1) dextran obstacles. The obtained Dlong values show better quantitative agreement with experiments than those obtained with hard-core spheres. Moreover, once parametrized, the CESP model is also able to quantitatively predict Dlong and the anomalous exponent (α) for streptavidin diffusion among D10, D400 and D700 dextran obstacles. Dlong, the short-time diffusion coefficient (Dshort) and α are obtained from the BD simulations by using a new empirical expression, able to describe the full temporal evolution of the diffusion coefficient.

  5. A smooth and differentiable bulk-solvent model for macromolecular diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Fenn, T. D. [Department of Molecular and Cellular Physiology and Howard Hughes Medical Institute, Stanford, California (United States); Schnieders, M. J. [Department of Chemistry, Stanford, California (United States); Brunger, A. T., E-mail: brunger@stanford.edu [Department of Molecular and Cellular Physiology and Howard Hughes Medical Institute, Stanford, California (United States); Departments of Neurology and Neurological Sciences, Structural Biology and Photon Science, Stanford, California (United States)

    2010-09-01

    A new method for modeling the bulk solvent in macromolecular diffraction data based on Babinet’s principle is presented. The proposed models offer the advantage of differentiability with respect to atomic coordinates. Inclusion of low-resolution data in macromolecular crystallography requires a model for the bulk solvent. Previous methods have used a binary mask to accomplish this, which has proven to be very effective, but the mask is discontinuous at the solute–solvent boundary (i.e. the mask value jumps from zero to one) and is not differentiable with respect to atomic parameters. Here, two algorithms are introduced for computing bulk-solvent models using either a polynomial switch or a smoothly thresholded product of Gaussians, and both models are shown to be efficient and differentiable with respect to atomic coordinates. These alternative bulk-solvent models offer algorithmic improvements, while showing similar agreement of the model with the observed amplitudes relative to the binary model as monitored using R, R{sub free} and differences between experimental and model phases. As with the standard solvent models, the alternative models improve the agreement primarily with lower resolution (>6 Å) data versus no bulk solvent. The models are easily implemented into crystallographic software packages and can be used as a general method for bulk-solvent correction in macromolecular crystallography.

  6. A smooth and differentiable bulk-solvent model for macromolecular diffraction

    International Nuclear Information System (INIS)

    Fenn, T. D.; Schnieders, M. J.; Brunger, A. T.

    2010-01-01

    A new method for modeling the bulk solvent in macromolecular diffraction data based on Babinet’s principle is presented. The proposed models offer the advantage of differentiability with respect to atomic coordinates. Inclusion of low-resolution data in macromolecular crystallography requires a model for the bulk solvent. Previous methods have used a binary mask to accomplish this, which has proven to be very effective, but the mask is discontinuous at the solute–solvent boundary (i.e. the mask value jumps from zero to one) and is not differentiable with respect to atomic parameters. Here, two algorithms are introduced for computing bulk-solvent models using either a polynomial switch or a smoothly thresholded product of Gaussians, and both models are shown to be efficient and differentiable with respect to atomic coordinates. These alternative bulk-solvent models offer algorithmic improvements, while showing similar agreement of the model with the observed amplitudes relative to the binary model as monitored using R, R free and differences between experimental and model phases. As with the standard solvent models, the alternative models improve the agreement primarily with lower resolution (>6 Å) data versus no bulk solvent. The models are easily implemented into crystallographic software packages and can be used as a general method for bulk-solvent correction in macromolecular crystallography

  7. Atomic Scale Structural Studies of Macromolecular Assemblies by Solid-state Nuclear Magnetic Resonance Spectroscopy.

    Science.gov (United States)

    Loquet, Antoine; Tolchard, James; Berbon, Melanie; Martinez, Denis; Habenstein, Birgit

    2017-09-17

    Supramolecular protein assemblies play fundamental roles in biological processes ranging from host-pathogen interaction, viral infection to the propagation of neurodegenerative disorders. Such assemblies consist in multiple protein subunits organized in a non-covalent way to form large macromolecular objects that can execute a variety of cellular functions or cause detrimental consequences. Atomic insights into the assembly mechanisms and the functioning of those macromolecular assemblies remain often scarce since their inherent insolubility and non-crystallinity often drastically reduces the quality of the data obtained from most techniques used in structural biology, such as X-ray crystallography and solution Nuclear Magnetic Resonance (NMR). We here present magic-angle spinning solid-state NMR spectroscopy (SSNMR) as a powerful method to investigate structures of macromolecular assemblies at atomic resolution. SSNMR can reveal atomic details on the assembled complex without size and solubility limitations. The protocol presented here describes the essential steps from the production of 13 C/ 15 N isotope-labeled macromolecular protein assemblies to the acquisition of standard SSNMR spectra and their analysis and interpretation. As an example, we show the pipeline of a SSNMR structural analysis of a filamentous protein assembly.

  8. Late adverse reactions to intravascular iodinated contrast media

    International Nuclear Information System (INIS)

    Webb, Judith A.W.; Stacul, Fulvio; Thomsen, Henrik S.; Morcos, Sameh K.

    2003-01-01

    Late adverse reactions to intravascular iodinated contrast media are defined as reactions occurring 1 h to 1 week after contrast medium injection. They have received increasing interest over the past decade, but their prevalence remains uncertain and their pathophysiology is not fully understood. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and to issue guidelines. An extensive literature search was carried out and summarized in a report. Based on the available information, simple guidelines have been drawn up. The report and guidelines were discussed at the 8th European Symposium on Urogenital Radiology in Genoa. Late adverse reactions after intravascular iodinated contrast medium include symptoms such as nausea, vomiting, headache, itching, skin rash, musculoskeletal pain, and fever. A significant proportion of these reactions is unrelated to the contrast medium; however, allergy-like skin reactions are well-documented side effects of contrast media with an incidence of approximately 2%. Late reactions appear to be commoner after non-ionic dimers. The majority of late skin reactions after contrast medium exposure are probably T-cell-mediated allergic reactions. Patients at increased risk of late skin reactions are those with a history of previous contrast medium reaction and those on interleukin-2 treatment. Most skin reactions are self-limiting and resolve within a week. Management is symptomatic and similar to the management of other drug-induced skin reactions. (orig.)

  9. A simple quantitative model of macromolecular crowding effects on protein folding: Application to the murine prion protein(121-231)

    Science.gov (United States)

    Bergasa-Caceres, Fernando; Rabitz, Herschel A.

    2013-06-01

    A model of protein folding kinetics is applied to study the effects of macromolecular crowding on protein folding rate and stability. Macromolecular crowding is found to promote a decrease of the entropic cost of folding of proteins that produces an increase of both the stability and the folding rate. The acceleration of the folding rate due to macromolecular crowding is shown to be a topology-dependent effect. The model is applied to the folding dynamics of the murine prion protein (121-231). The differential effect of macromolecular crowding as a function of protein topology suffices to make non-native configurations relatively more accessible.

  10. Prolonged retainment of contrast media in renal tumours by oily X-ray contrast media

    International Nuclear Information System (INIS)

    Ryzkov, V.K.; Anisimov, V.N.

    1990-01-01

    In 194 patients with renal tumours an angiographic investigation with the oily X-ray contrast medium Iodolipol was carried out. A selective tropism of oily X-ray contrast media was found in the malignant zones only. The application of the preparation caused no complications. The oily X-ray contrast medium persisted in the tumours over several weeks or months. After embolization of the renal arteria a moderate size reduction of malign tumours in the first 10-14 d was seen. The ability of Iodolipol for a lasting retainment in malign tumour tissue allows a follow-up of the involution of the pathologic focus after arterial embolization of the tumour vessels. (author)

  11. The Postgraduate Study of Macromolecular Sciences at the University of Zagreb (1971-1980

    Directory of Open Access Journals (Sweden)

    Kunst, B.

    2008-07-01

    Full Text Available The postgraduate study of macromolecular sciences (PSMS was established at the University of Zagreb in 1971 as a university study in the time of expressed interdisciplinary permeation of natural sciences - physics, chemistry and biology, and application of their achievements in technologicaldisciplines. PSMS was established by a group of prominent university professors from the schools of Science, Chemical Technology, Pharmacy and Medicine, as well as from the Institute of Biology. The study comprised basic fields of macromolecular sciences: organic chemistry of synthetic macromolecules, physical chemistry of macromolecules, physics of macromolecules, biological macromolecules and polymer engineering with polymer application and processing, and teaching was performed in 29 lecture courses lead by 30 professors with their collaborators. PSMS ceased to exist with the change of legislation in Croatia in 1980, when the attitude prevailed to render back postgraduate studies to the university schools. During 9 years of existence of PSMS the MSci grade was awarded to 37 macromolecular experts. It was assessed that the PSMS some thirty years ago was an important example of modern postgraduate education as compared with the international postgraduate development. In concordance with the recent introduction of similar interdisciplinary studies in macromolecular sciences elsewhere in the world, the establishment of a modern interdisciplinary study in the field would be of importance for further development of these sciences in Croatia.

  12. Synthesis and characterization of macromolecular rhodamine tethers and their interactions with P-glycoprotein.

    Science.gov (United States)

    Crawford, Lindsey; Putnam, David

    2014-08-20

    Rhodamine dyes are well-known P-glycoprotein (P-gp) substrates that have played an important role in the detection of inhibitors and other substrates of P-gp, as well as in the understanding of P-gp function. Macromolecular conjugates of rhodamines could prove useful as tethers for further probing of P-gp structure and function. Two macromolecular derivatives of rhodamine, methoxypolyethylene glycol-rhodamine6G and methoxypolyethylene glycol-rhodamine123, were synthesized through the 2'-position of rhodamine6G and rhodamine123, thoroughly characterized, and then evaluated by inhibition with verapamil for their ability to interact with P-gp and to act as efflux substrates. To put the results into context, the P-gp interactions of the new conjugates were compared to the commercially available methoxypolyethylene glycol-rhodamineB. FACS analysis confirmed that macromolecular tethers of rhodamine6G, rhodamine123, and rhodamineB were accumulated in P-gp expressing cells 5.2 ± 0.3%, 26.2 ± 4%, and 64.2 ± 6%, respectively, compared to a sensitive cell line that does not overexpress P-gp. Along with confocal imaging, the efflux analysis confirmed that the macromolecular rhodamine tethers remain P-gp substrates. These results open potential avenues for new ways to probe the function of P-gp both in vitro and in vivo.

  13. Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors

    International Nuclear Information System (INIS)

    Kawatani, Yohei; Nakamura, Yoshitsugu; Mochida, Yoshihiko; Yamauchi, Naoya; Hayashi, Yujiro; Taneichi, Tetsuyoshi; Ito, Yujiro; Kurobe, Hirotsugu; Suda, Yuji; Hori, Takaki

    2016-01-01

    Endovascular stent graft placement has become a major treatment for thoracic and abdominal aneurysms. While endovascular therapy is less invasive than open surgery, it involves the use of a contrast medium. Contrast media can cause renal impairment, a condition termed as contrast-induced nephropathy (CIN). This study sought to evaluate the incidence and risk factors of CIN following endovascular stent graft placement for aortic aneurysm repair. The study included 167 consecutive patients who underwent endovascular stent graft placement in our hospital from October 2013 to June 2014. CIN was diagnosed using the European Society of Urogenital Radiology criteria. Patients with and without CIN were compared. Chi-squared tests, t-tests, and multivariate logistic regression analyses were performed. Thirteen patients (7.8%) developed CIN. Left ventricular dysfunction and intraoperative blood transfusion were significantly more frequent in the CIN group (P = 0.017 and P = 0.032, resp.). Multivariate analysis showed that left ventricular dysfunction had the strongest influence on CIN development (odds ratio 9.34, P = 0.018, and 95% CI = 1.46–59.7). Patients with CIN also experienced longer ICU and hospital stays. Measures to improve renal perfusion flow should be considered for patients with left ventricular dysfunction who are undergoing endovascular stent graft placement

  14. Use of high concentration contrast media: principles and rationale--vascular district

    International Nuclear Information System (INIS)

    Fleischmann, Dominik.

    2003-01-01

    Optimal contrast medium delivery remains a crucial issue in CT angiography and it will become even more critical with continuously evolving, faster CT scanner technology. This review article first explains the fundamentals of arterial enhancement using mathematical models of early contrast medium dynamics. The relationship of contrast medium volume, injection flow rates and injection duration are explicitly illustrated. Next, current techniques of contrast medium application are reviewed, with particular attention to methods of accurate timing of the scanning delay (test-bolus and automated bolus triggering), tools for automated saline-flushing of the veins (double-syringe power injectors) and the use of high-concentration contrast medium. From there, rational CT angiographic injection protocols for a wide range of selectable acquisition times for 4-, 8- and 16-channel MDCT are proposed

  15. Iodine-based contrast media, multiple myeloma and monoclonal gammopathies: literature review and ESUR Contrast Media Safety Committee guidelines.

    Science.gov (United States)

    Stacul, Fulvio; Bertolotto, Michele; Thomsen, Henrik S; Pozzato, Gabriele; Ugolini, Donatella; Bellin, Marie-France; Bongartz, Georg; Clement, Olivier; Heinz-Peer, Gertraud; van der Molen, Aart; Reimer, Peter; Webb, Judith A W

    2018-02-01

    Many radiologists and clinicians still consider multiple myeloma (MM) and monoclonal gammopathies (MG) a contraindication for using iodine-based contrast media. The ESUR Contrast Media Safety Committee performed a systematic review of the incidence of post-contrast acute kidney injury (PC-AKI) in these patients. A systematic search in Medline and Scopus databases was performed for renal function deterioration studies in patients with MM or MG following administration of iodine-based contrast media. Data collection and analysis were performed according to the PRISMA statement 2009. Eligibility criteria and methods of analysis were specified in advance. Cohort and case-control studies reporting changes in renal function were included. Thirteen studies were selected that reported 824 iodine-based contrast medium administrations in 642 patients with MM or MG, in which 12 unconfounded cases of PC-AKI were found (1.6 %). The majority of patients had intravenous urography with high osmolality ionic contrast media after preparatory dehydration and purgation. MM and MG alone are not risk factors for PC-AKI. However, the risk of PC-AKI may become significant in dehydrated patients with impaired renal function. Hypercalcaemia may increase the risk of kidney damage, and should be corrected before contrast medium administration. Assessment for Bence-Jones proteinuria is not necessary. • Monoclonal gammopathies including multiple myeloma are a large spectrum of disorders. • In monoclonal gammopathy with normal renal function, PC-AKI risk is not increased. • Renal function is often reduced in myeloma, increasing the risk of PC-AKI. • Correction of hypercalcaemia is necessary in myeloma before iodine-based contrast medium administration. • Bence-Jones proteinuria assessment in myeloma is unnecessary before iodine-based contrast medium administration.

  16. MMTF-An efficient file format for the transmission, visualization, and analysis of macromolecular structures.

    Directory of Open Access Journals (Sweden)

    Anthony R Bradley

    2017-06-01

    Full Text Available Recent advances in experimental techniques have led to a rapid growth in complexity, size, and number of macromolecular structures that are made available through the Protein Data Bank. This creates a challenge for macromolecular visualization and analysis. Macromolecular structure files, such as PDB or PDBx/mmCIF files can be slow to transfer, parse, and hard to incorporate into third-party software tools. Here, we present a new binary and compressed data representation, the MacroMolecular Transmission Format, MMTF, as well as software implementations in several languages that have been developed around it, which address these issues. We describe the new format and its APIs and demonstrate that it is several times faster to parse, and about a quarter of the file size of the current standard format, PDBx/mmCIF. As a consequence of the new data representation, it is now possible to visualize structures with millions of atoms in a web browser, keep the whole PDB archive in memory or parse it within few minutes on average computers, which opens up a new way of thinking how to design and implement efficient algorithms in structural bioinformatics. The PDB archive is available in MMTF file format through web services and data that are updated on a weekly basis.

  17. Diffusion accessibility as a method for visualizing macromolecular surface geometry.

    Science.gov (United States)

    Tsai, Yingssu; Holton, Thomas; Yeates, Todd O

    2015-10-01

    Important three-dimensional spatial features such as depth and surface concavity can be difficult to convey clearly in the context of two-dimensional images. In the area of macromolecular visualization, the computer graphics technique of ray-tracing can be helpful, but further techniques for emphasizing surface concavity can give clearer perceptions of depth. The notion of diffusion accessibility is well-suited for emphasizing such features of macromolecular surfaces, but a method for calculating diffusion accessibility has not been made widely available. Here we make available a web-based platform that performs the necessary calculation by solving the Laplace equation for steady state diffusion, and produces scripts for visualization that emphasize surface depth by coloring according to diffusion accessibility. The URL is http://services.mbi.ucla.edu/DiffAcc/. © 2015 The Protein Society.

  18. Local analysis of strains and rotations for macromolecular electron microscopy maps

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Ramos, A.; Prieto, F.; Melero, R.; Martin-Benito, J.; Jonic, S.; Navas-Calvente, J.; Vargas, J.; Oton, J.; Abrishami, V.; Rosa-Trevin, J.L. de la; Gomez-Blanco, J.; Vilas, J.L.; Marabini, R.; Carazo, R.; Sorzano, C.O.S.

    2016-07-01

    Macromolecular complexes can be considered as molecular nano-machines that must have mobile parts in order to perform their physiological functions. The reordering of their parts is essential to execute their task. These rearrangements induce local strains and rotations which, after analyzing them, may provide relevant information about how the proteins perform their function. In this project these deformations of the macromolecular complexes are characterized, translating into a “mathematical language” the conformational changes of the complexes when they perform their function. Electron Microscopy (EM) volumes are analyzed using a method that uses B-splines as its basis functions. It is shown that the results obtained are consistent with the conformational changes described in their corresponding reference publications. (Author)

  19. Influence of osmolarity of contrast medium and saline flush on computed tomography angiography: Comparison of monomeric and dimeric iodinated contrast media with different iodine concentrations at an identical iodine delivery rate

    International Nuclear Information System (INIS)

    Kishimoto, Miori; Doi, Shoko; Shimizu, Junichiro; Lee, Ki-Ja; Iwasaki, Toshiroh; Miyake, Yoh-Ichi; Yamada, Kazutaka

    2010-01-01

    Purpose: To evaluate the influence of osmolarity of iodinated contrast media and saline flush on the contrast effect in thoracic computed tomography angiography (CTA) at an identical iodine delivery rate (IDR). Materials and methods: Seven beagles were used in a cross-over experiment. The contrast media used were iohexol 350 mgI/ml (IOH350; osmolarity 844 mmol/kg) and iodixanol 320 mgI/ml (IDX320; osmolarity 290 mmol/kg). Each contrast medium was administered to groups with and without saline flush at 40.0 mgI/kg/s for all experiments. Dynamic CT scanning was performed at the ninth thoracic vertebra level. The peak value, area under the curve (AUC), and time to peak (TTP) were calculated from the time attenuation curves of the pulmonary artery and aorta. Results: There was no significant difference between IOH350 and IDX320 with or without saline flush in the peak values for the pulmonary artery and aorta. AUC was significantly higher in groups with saline flush for both contrast media and arteries (p < 0.05) with no significant difference between contrast media. TTP was significantly longer in groups with saline flush than without saline flush for both contrast media and arteries (p < 0.05), with no significant difference between contrast media. Conclusions: There were no significant differences in the contrast effects of monomeric IOH350 and dimeric IDX320 in thoracic CTA when used at an identical IDR. Moreover, saline flush prolonged the peak duration at 600 mgI/kg.

  20. [Macromolecular aromatic network characteristics of Chinese power coal analyzed by synchronous fluorescence and X-ray diffraction].

    Science.gov (United States)

    Ye, Cui-Ping; Feng, Jie; Li, Wen-Ying

    2012-07-01

    Coal structure, especially the macromolecular aromatic skeleton structure, has a strong influence on coke reactivity and coal gasification, so it is the key to grasp the macromolecular aromatic skeleton coal structure for getting the reasonable high efficiency utilization of coal. However, it is difficult to acquire their information due to the complex compositions and structure of coal. It has been found that the macromolecular aromatic network coal structure would be most isolated if small molecular of coal was first extracted. Then the macromolecular aromatic skeleton coal structure would be clearly analyzed by instruments, such as X-ray diffraction (XRD), fluorescence spectroscopy with synchronous mode (Syn-F), Gel permeation chromatography (GPC) etc. Based on the previous results, according to the stepwise fractional liquid extraction, two Chinese typical power coals, PS and HDG, were extracted by silica gel as stationary phase and acetonitrile, tetrahydrofuran (THF), pyridine and 1-methyl-2-pyrollidinone (NMP) as a solvent group for sequential elution. GPC, Syn-F and XRD were applied to investigate molecular mass distribution, condensed aromatic structure and crystal characteristics. The results showed that the size of aromatic layers (La) is small (3-3.95 nm) and the stacking heights (Lc) are 0.8-1.2 nm. The molecular mass distribution of the macromolecular aromatic network structure is between 400 and 1 130 amu, with condensed aromatic numbers of 3-7 in the structure units.

  1. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT - A pooled analysis of two randomized trials

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.; Morcos, Sameh K.

    2009-01-01

    The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients with glomerular filtration rate (GFR) 40 ml/min, 4.6% when GFR <40 ml/min and 7.8% in patients with GFR <30 ml/min. The incidence of CIN was significantly higher after iodixanol than after LOCM (seven patients, 4.7% following IOCM, no CIN cases following the LOCM; p = 0.007). Significant differences in favor of the LOCM were also observed in patients with GFR <40 ml/min and GFR <30 ml/min. Following the IV administration of nonionic contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM iopamidol and iomeprol, especially in high-risk patients. Differences in osmolality between these LOCM and iodixanol do not play a role in the genesis of CIN. (orig.)

  2. Consideration of Adverse Reaction to MDCT Contrast Media

    International Nuclear Information System (INIS)

    Yang, Won Seok; Shin, Seong Gyu

    2012-01-01

    In this experiment, we investigated 82 patients who suffered adverse reactions due to contrast medium. We selected the subjects out of 21,178 people who had an intravenous injection of contrast medium to undergo MDCT examination at one university hospital in Busan in 2007. As a result, the largest groups of the patients were as follows. 52.4% of the patients were male when classify by gender; 28.0% of the patients were 50's by age; 45% of the patients got when it was spring(April and March); 75.6% of the patients had a side effects when the speed of injection is 2.5 mL/sec; 58.5% of the patients were suffered when the volume of injected contrast medium is over 130 mL. Urticaria was the main symptom of side effect as 26.8%. And the main treatment for the effect was alleviating the symptoms before making patients to return home. Thus, practical preventive measures are needed as follows: use the OCS system to observe warning signs at risky patients, secure warming spaces for patients to cope with season changing, prepare enough emergency kits for the patients in danger, and establish CPR call systems, explain the risk of contrast medium and get agree about using contrast medium.

  3. Flexibility damps macromolecular crowding effects on protein folding dynamics: Application to the murine prion protein (121-231)

    Science.gov (United States)

    Bergasa-Caceres, Fernando; Rabitz, Herschel A.

    2014-01-01

    A model of protein folding kinetics is applied to study the combined effects of protein flexibility and macromolecular crowding on protein folding rate and stability. It is found that the increase in stability and folding rate promoted by macromolecular crowding is damped for proteins with highly flexible native structures. The model is applied to the folding dynamics of the murine prion protein (121-231). It is found that the high flexibility of the native isoform of the murine prion protein (121-231) reduces the effects of macromolecular crowding on its folding dynamics. The relevance of these findings for the pathogenic mechanism are discussed.

  4. Effect of contrast media iodine concentration on bolus tracking

    International Nuclear Information System (INIS)

    Ishihara, Toshihiro; Hayashi, Takayuki; Nakaya, Yoshihiro; Naoi, Kuniji; Ikeno, Naoya; Kobayashi, Tatsushi; Satake, Mitsuo

    2006-01-01

    Computer-assisted bolus tracking has been confirmed to be a useful technique in computed tomography (CT) imaging and allows images to be captured with automated timing. The inflow of the contrast medium is monitored, and when the contrast medium reaches a predetermined level, CT image capture starts automatically. However, it has been shown that the preset threshold value of contrast medium is affected by its iodine concentration, which causes variations in image capture times. Greater speed in current multislice CT imaging requires that medical technicians pay more attention to setting the timing of image capture during venous examinations by taking into account the iodine concentration in contrast media. (author)

  5. MRI with intrathecal MRI gadolinium contrast medium administration: a possible method to assess glymphatic function in human brain

    International Nuclear Information System (INIS)

    Eide, Per Kristian; Ringstad, Geir

    2015-01-01

    Recently, the “glymphatic system” of the brain has been discovered in rodents, which is a paravascular, transparenchymal route for clearance of excess brain metabolites and distribution of compounds in the cerebrospinal fluid. It has already been demonstrated that intrathecally administered gadolinium (Gd) contrast medium distributes along this route in rats, but so far not in humans. A 27-year-old woman underwent magnetic resonance imaging (MRI) with intrathecal administration of gadobutrol, which distributed throughout her entire brain after 1 and 4.5 h. MRI with intrathecal Gd may become a tool to study glymphatic function in the human brain

  6. MRI with intrathecal MRI gadolinium contrast medium administration: a possible method to assess glymphatic function in human brain.

    Science.gov (United States)

    Eide, Per Kristian; Ringstad, Geir

    2015-11-01

    Recently, the "glymphatic system" of the brain has been discovered in rodents, which is a paravascular, transparenchymal route for clearance of excess brain metabolites and distribution of compounds in the cerebrospinal fluid. It has already been demonstrated that intrathecally administered gadolinium (Gd) contrast medium distributes along this route in rats, but so far not in humans. A 27-year-old woman underwent magnetic resonance imaging (MRI) with intrathecal administration of gadobutrol, which distributed throughout her entire brain after 1 and 4.5 h. MRI with intrathecal Gd may become a tool to study glymphatic function in the human brain.

  7. Improved specimen reconstruction by Hilbert phase contrast tomography.

    Science.gov (United States)

    Barton, Bastian; Joos, Friederike; Schröder, Rasmus R

    2008-11-01

    The low signal-to-noise ratio (SNR) in images of unstained specimens recorded with conventional defocus phase contrast makes it difficult to interpret 3D volumes obtained by electron tomography (ET). The high defocus applied for conventional tilt series generates some phase contrast but leads to an incomplete transfer of object information. For tomography of biological weak-phase objects, optimal image contrast and subsequently an optimized SNR are essential for the reconstruction of details such as macromolecular assemblies at molecular resolution. The problem of low contrast can be partially solved by applying a Hilbert phase plate positioned in the back focal plane (BFP) of the objective lens while recording images in Gaussian focus. Images recorded with the Hilbert phase plate provide optimized positive phase contrast at low spatial frequencies, and the contrast transfer in principle extends to the information limit of the microscope. The antisymmetric Hilbert phase contrast (HPC) can be numerically converted into isotropic contrast, which is equivalent to the contrast obtained by a Zernike phase plate. Thus, in-focus HPC provides optimal structure factor information without limiting effects of the transfer function. In this article, we present the first electron tomograms of biological specimens reconstructed from Hilbert phase plate image series. We outline the technical implementation of the phase plate and demonstrate that the technique is routinely applicable for tomography. A comparison between conventional defocus tomograms and in-focus HPC volumes shows an enhanced SNR and an improved specimen visibility for in-focus Hilbert tomography.

  8. Addition of lacal anesthetics to contrast media. Pt. 2

    International Nuclear Information System (INIS)

    Nilsson, P.; Almen, T.; Golman, K.; Jonsson, K.; Nyman, U.; Malmoe Allmaenna Sjukhus

    1988-01-01

    The acute intravenous toxicity (i.v. LD 50 ) of solutions of the ratio 1.5 contrast media metrizoate or diatrizoate and the ratio 3.0 contrast medium metrizamide was determined in mice with and without the addition of local anesthetics to the solutions. The two local anesthetics mepivacaine or lidocaine were added to final concentrations up to 2.0 mg/ml of the contrast medium solutions. This corresponds to clinically used concentrations. All additions of local anesthetics to the solutions increased the mortalities caused by the contrast medium solutions. Addition of local anesthetics to a final concentration of 2 mg/ml approximately doubled the acute intravenous toxicity of the contrast media. The ratio 3 contrast media produce less hypertonic solutions than the ratio 1.5 contrast media and should be preferred for angiography because they cause less pain and do not require the addition of local anesthetics which increase the acute toxicity of the solutions. (orig.)

  9. Contrast media in computed tomography of the pelvic organs

    International Nuclear Information System (INIS)

    Husband, J.E.

    1981-01-01

    The use of various contrast media is essential for examination of the pelvis with computed tomography (CT) because there is little fat between the organs and structures and because bowel may be misinterpreted as mass. Routine opacification of the distal small bowel and colon is achieved using dilute oral and rectal contrast medium, and all patients are scanned with a full bladder. A tampon is used to outline the vaginal vault. Intravenous contrast medium may be required to opacify the urinary tract or to distinguish vessels from a suspected space-occupying lesion. Pelvic masses may show tissue enhancement following injection of intravenous contrast medium but further studies are required to determine the diagnostic value of the information obtained. (Auth.)

  10. Hydration for the prevention of contrast medium-induced nephropathy. An update

    International Nuclear Information System (INIS)

    Heinrich, M.; Uder, M.

    2006-01-01

    Contrast medium-induced nephropathy (CIN) continues to be one of the most common causes of hospital-acquired acute renal failure. Since most of the clinical studies on the prophylactic use of different drugs to prevent CIN produced disappointing results, hydration remains the mainstay of prophylaxis. A number of recent prospective randomized trials provided further evidence of the effectiveness of hydration and relevant information regarding the optimization of hydration protocols. It was shown that a bolus hydration solely during examination is not sufficient to prevent CIN. In addition, isotonic 0.9% saline was superior to the commonly used halfisotonic 0.45% saline in another trial. An outpatient hydration protocol including oral hydration before the examination followed by forced intravenous hydration over 6 hrs. beginning 30 to 60 min. prior to examination seems to be comparable to the usual hydration over 24 hrs. Another hydration protocol, which could also be very attractive especially for outpatients, included the infusion of sodium bicarbonate. In a recent trial, hydration with sodium bicarbonate, given as a bolus for 1 hr. prior to examination followed by an infusion for 6 hrs. after examination, was more effective than hydration with sodium chloride for the prophylaxis of CIN. However, there is still a lack of large-scale, multi-center trials comparing different hydration protocols and investigating their influence on clinically relevant endpoints such as mortality or the need for dialysis. (orig.)

  11. Contrast-enhanced MR imaging monitoring of acute tumor response to chemotherapy

    International Nuclear Information System (INIS)

    Ranney, D.F.; Cohen, J.M.; Antich, P.P.; Endman, W.A.; Kulkarni, P.; Weinreb, J.C.; Giovanella, B.

    1987-01-01

    Treatment responses of human malignant melanomas were monitored at millimeter resolution in athymic mice by injecting a new polymeric contrast agent, Gd-DTPA-dextran (0.1 mmol Gd/kg, intravenously). Proton MR imaging (0.35 T, spin-echo, repetition time = 0.5 second, echo time = 50 msec) was performed 30 hours after administering diphtheria toxin. Pre-contrast medium images revealed only homogeneous intermediate-intensity tumor masses. Post-contrast medium images of untreated (viable) tumors demonstrated 32% enhancement throughout the entire mass. Post-contrast medium images of toxin-treated tumors revealed marked enhancement (65%) of the histologically viable outer rims, lesser enhancement (38%) of heavily damaged subregions, and no enhancement of dead tumor. These acute, contrast medium-enhanced MR images accurately identified tumor subregions that survived for longer than one week

  12. Choice of intravenous contrast material for CT

    International Nuclear Information System (INIS)

    Cohen, M.D.; Herman, E.; Herron, D.; White, S.T.; Smith, J.A.; Cory, D.A.

    1989-01-01

    For CT, minor side effects (e.g., nausea, vomiting, pain) following intravenous administration of contrast medium may degrade image quality by causing patient motion or by delaying scanning. The objective of this study was to see if nonionic contrast agents offer advantages in reducing the incidence of such side effects. One hundred five pediatric patients randomly received iohexol (Omnipaque), Iopamidol (Isovue), or diatrizoate sodium (Hypaque). Contrast medium was given in doses of 2 mL/kg body weight (300 mg of iodine per milliliter). The results are presented in the paper

  13. Macromolecular crystallography research at Trombay

    International Nuclear Information System (INIS)

    Kannan, K.K.; Chidamrabam, R.

    1983-01-01

    Neutron diffraction studies of hydrogen positions in small molecules of biological interest at Trombay have provided valuable information that has been used in protein and enzyme structure model-building and in developing hydrogen bond potential functions. The new R-5 reactor is expected to provide higher neutron fluxes and also make possible small-angle neutron scattering studies of large biomolecules and bio-aggregates. In the last few years infrastructure facilities have also been established for macromolecular x-ray crystallography research. Meanwhile, the refinement of carbonic hydrases and lyysozyme structures have been carried out and interesting results obtained on protein dynamics and structure-function relationships. Some interesting presynaptic toxin phospholipases have also taken up for study. (author)

  14. Iohexol for contrast enhancement of bowel in pediatric abdominal CT

    International Nuclear Information System (INIS)

    Smevik, B.; Westvik, J.

    1990-01-01

    Abdominal CT scans from 160 examinations performed on pediatric patients using iohexol 2 percent as contrast medium for bowel enhancement were evaluated retrospectively. When diluted with a beverage of the child's choice, iohexol has a neutral taste and cannot be detected, and 139 out of 142 patients drank the full amount of dilute contrast offered to them. The enhancement of bowel in the area of interest was graded as good (58%), reasonable (23%), or poor (19%). The contrast medium was prepared from leftovers from our angiocardiography studies. We conclude that the use of water-soluble contrast medium in a low concentration is a safe and cost-effective way of facilitating ingesion of sufficient amounts of the medium in oncologic pediatric patients undergoing cytotoxic and/or radiation treatment. (orig.)

  15. Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Minwen, E-mail: zhengmw2007@163.com; Liu, Ying, E-mail: yingyinglyly@126.com; Wei, Mengqi, E-mail: weimengqi2008@163.com; Wu, Yongjie, E-mail: wu18291988526@163.com; Zhao, Hongliang, E-mail: zhaohl1980@163.com; Li, Jian, E-mail: xjyylj@yeah.net

    2014-02-15

    Objectives: To assess the impact of low-concentration contrast medium on vascular enhancement, image quality and radiation dose of coronary CT angiography (cCTA) by using a combination of iterative reconstruction (IR) and low-tube-voltage technique. Materials and methods: One hundred patients were prospectively randomized to two types of contrast medium and underwent prospective electrocardiogram-triggering cCTA (Definition Flash, Siemens Healthcare; collimation: 128 mm × 0.6 mm; tube current: 300 mA s). Fifty patients received Iopromide 370 were scanned using the conventional tube setting (100 kVp or 120 kVp if BMI ≥ 25 kg/m{sup 2}) and reconstructed with filtered back projection (FBP). Fifty patients received Iodixanol 270 were scanned using the low-tube-voltage (80 kVp or 100 kVp if BMI ≥ 25 kg/m{sup 2}) technique and reconstructed with IR. CT attenuation was measured in coronary artery and other anatomical regions. Noise, image quality and radiation dose were compared. Results: Compared with two Iopromide 370 subgroups, Iomeprol 270 subgroups showed no significant difference in CT attenuation (576.63 ± 95.50 vs. 569.51 ± 118.93 for BMI < 25 kg/m{sup 2}, p = 0.647 and 394.19 ± 68.09 vs. 383.72 ± 63.11 for BMI ≥ 25 kg/m{sup 2}, p = 0.212), noise (in various anatomical regions of interest) and image quality (3.5 vs. 4.0, p = 0.13), but significantly (0.41 ± 0.17 vs. 0.94 ± 0.45 for BMI < 25 kg/m{sup 2}, p < 0.001 and 1.14 ± 0.24 vs. 2.37 ± 0.69 for BMI ≥ 25 kg/m{sup 2}, p < 0.001) lower radiation dose, which reflects dose saving of 56.4% and 51.9%, respectively. Conclusions: Combined IR with low-tube-voltage technique, a low-concentration contrast medium of 270 mg I/ml can still maintain the contrast enhancement without impairing image quality, as well as significantly lower the radiation dose.

  16. Dexamethasone attenuates grain sorghum dust extract-induced increase in macromolecular efflux in vivo.

    Science.gov (United States)

    Akhter, S R; Ikezaki, H; Gao, X P; Rubinstein, I

    1999-05-01

    The purpose of this study was to determine whether dexamethasone attenuates grain sorghum dust extract-induced increase in macromolecular efflux from the in situ hamster cheek pouch and, if so, whether this response is specific. By using intravital microscopy, we found that an aqueous extract of grain sorghum dust elicited significant, concentration-dependent leaky site formation and increase in clearance of FITC-labeled dextran (FITC-dextran; mol mass, 70 kDa) from the in situ hamster cheek pouch (P grain sorghum dust extract- and substance P-induced increases in macromolecular efflux from the in situ hamster cheek pouch in a specific fashion.

  17. The Joint Structural Biology Group beam lines at the ESRF: Modern macromolecular crystallography

    CERN Document Server

    Mitchell, E P

    2001-01-01

    Macromolecular crystallography has evolved considerably over the last decade. Data sets in under an hour are now possible on high throughput beam lines leading to electron density and, possibly, initial models calculated on-site. There are five beam lines currently dedicated to macromolecular crystallography: the ID14 complex and BM-14 (soon to be superseded by ID-29). These lines handle over five hundred projects every six months and demand is increasing. Automated sample handling, alignment and data management protocols will be required to work efficiently with this demanding load. Projects developing these themes are underway within the JSBG.

  18. Isotope labeling for NMR studies of macromolecular structure and interactions

    International Nuclear Information System (INIS)

    Wright, P.E.

    1994-01-01

    Implementation of biosynthetic methods for uniform or specific isotope labeling of proteins, coupled with the recent development of powerful heteronuclear multidimensional NMR methods, has led to a dramatic increase in the size and complexity of macromolecular systems that are now amenable to NMR structural analysis. In recent years, a new technology has emerged that combines uniform 13 C, 15 N labeling with heteronuclear multidimensional NMR methods to allow NMR structural studies of systems approaching 25 to 30 kDa in molecular weight. In addition, with the introduction of specific 13 C and 15 N labels into ligands, meaningful NMR studies of complexes of even higher molecular weight have become feasible. These advances usher in a new era in which the earlier, rather stringent molecular weight limitations have been greatly surpassed and NMR can begin to address many central biological problems that involve macromolecular structure, dynamics, and interactions

  19. Isotope labeling for NMR studies of macromolecular structure and interactions

    Energy Technology Data Exchange (ETDEWEB)

    Wright, P.E. [Scripps Research Institute, La Jolla, CA (United States)

    1994-12-01

    Implementation of biosynthetic methods for uniform or specific isotope labeling of proteins, coupled with the recent development of powerful heteronuclear multidimensional NMR methods, has led to a dramatic increase in the size and complexity of macromolecular systems that are now amenable to NMR structural analysis. In recent years, a new technology has emerged that combines uniform {sup 13}C, {sup 15}N labeling with heteronuclear multidimensional NMR methods to allow NMR structural studies of systems approaching 25 to 30 kDa in molecular weight. In addition, with the introduction of specific {sup 13}C and {sup 15}N labels into ligands, meaningful NMR studies of complexes of even higher molecular weight have become feasible. These advances usher in a new era in which the earlier, rather stringent molecular weight limitations have been greatly surpassed and NMR can begin to address many central biological problems that involve macromolecular structure, dynamics, and interactions.

  20. Macromolecular shape and interactions in layer-by-layer assemblies within cylindrical nanopores.

    Science.gov (United States)

    Lazzara, Thomas D; Lau, K H Aaron; Knoll, Wolfgang; Janshoff, Andreas; Steinem, Claudia

    2012-01-01

    Layer-by-layer (LbL) deposition of polyelectrolytes and proteins within the cylindrical nanopores of anodic aluminum oxide (AAO) membranes was studied by optical waveguide spectroscopy (OWS). AAO has aligned cylindrical, nonintersecting pores with a defined pore diameter d(0) and functions as a planar optical waveguide so as to monitor, in situ, the LbL process by OWS. The LbL deposition of globular proteins, i.e., avidin and biotinylated bovine serum albumin was compared with that of linear polyelectrolytes (linear-PEs), both species being of similar molecular weight. LbL deposition within the cylindrical AAO geometry for different pore diameters (d(0) = 25-80 nm) for the various macromolecular species, showed that the multilayer film growth was inhibited at different maximum numbers of LbL steps (n(max)). The value of n(max) was greatest for linear-PEs, while proteins had a lower value. The cylindrical pore geometry imposes a physical limit to LbL growth such that n(max) is strongly dependent on the overall internal structure of the LbL film. For all macromolecular species, deposition was inhibited in native AAO, having pores of d(0) = 25-30 nm. Both, OWS and scanning electron microscopy showed that LbL growth in larger AAO pores (d(0) > 25-30 nm) became inhibited when approaching a pore diameter of d(eff,n_max) = 25-35 nm, a similar size to that of native AAO pores, with d(0) = 25-30 nm. For a reasonable estimation of d(eff,n_max), the actual volume occupied by a macromolecular assembly must be taken into consideration. The results clearly show that electrostatic LbL allowed for compact macromolecular layers, whereas proteins formed loosely packed multilayers.

  1. Effects of acetylcysteine and probucol on contrast medium-induced depression of intrinsic renal glutathione peroxidase activity in diabetic rats.

    Science.gov (United States)

    Yen, Hsueh-Wei; Lee, Hsiang-Chun; Lai, Wen-Te; Sheu, Sheng-Hsiung

    2007-04-01

    Antioxidants such as N-acetylcysteine and probucol have been used to protect patients from contrast media-induced nephrotoxicity. The mechanisms underlying these protective effects are not well understood. We hypothesized that acetylcysteine and probucol alter the activity of endogenous antioxidant enzyme activity. Four weeks after induction of diabetes with streptozotocin, diabetic and nondiabetic rats were divided into three groups. Group 1 rats did not receive any antioxidant agents. Group 2 rats were treated with acetylcysteine and group 3 rats with probucol for 1 week before injection of the contrast medium diatrizoate (DTZ). We found that diabetic rats had higher renal glutathione peroxidase (GPx) activity than normal rats. DTZ suppressed renal GPx activity significantly in both group 1 diabetic and normal rats. Interestingly, renal GPx activity in both diabetic and normal rats pretreated with acetylcysteine or probucol was not inhibited by DTZ. Renal superoxide dismutase (SOD) increased significantly in normal rats after DTZ injection, but not in diabetic rats. Finally, acetylcysteine or probucol did not significantly influence renal SOD. These findings suggest that the renal protective effects of acetylcysteine and probucol against contrast-induced oxidative stress and nephrotoxicity may be mediated by altering endogenous GPx activity.

  2. Variationally optimal selection of slow coordinates and reaction coordinates in macromolecular systems

    Science.gov (United States)

    Noe, Frank

    To efficiently simulate and generate understanding from simulations of complex macromolecular systems, the concept of slow collective coordinates or reaction coordinates is of fundamental importance. Here we will introduce variational approaches to approximate the slow coordinates and the reaction coordinates between selected end-states given MD simulations of the macromolecular system and a (possibly large) basis set of candidate coordinates. We will then discuss how to select physically intuitive order paremeters that are good surrogates of this variationally optimal result. These result can be used in order to construct Markov state models or other models of the stationary and kinetics properties, in order to parametrize low-dimensional / coarse-grained model of the dynamics. Deutsche Forschungsgemeinschaft, European Research Council.

  3. Renal effects of the non-ionic contrast medium iopentol after intravenous injection in healthy volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Jakobsen, J.A.; Berg, K.J.; Waaler, A.; Andrew, E. (Rikshospitalet, Oslo (Norway). Dept. of Radiology Rikshospitalet, Oslo (Norway). Renal Section Nycomed A/S, Oslo (Norway). Dept. of Clinical Research and Development)

    1990-01-01

    Renal effects of the new non-ionic contrast medium iopentol in increasing doses were assessed and compared with the effects of physiologic saline. Twenty-four healthy male volunteers, allocated to three dose groups, were given iopentol intravenously in doses of 0.3, 0.6, and 1.2 g I/kg body weight, respectively. The highest dose group was also given physiologic saline separately as a control. The diuresis increased in all groups, most in the highest dose group, and with a concomitant fall of urine osmolality and increase in osmolar clearance. A slight decrease of serum osmolality, creatinine and urea occurred at 3 hours due to hemodilution. The glomerular filtration rate was unaffected by iopentol. The urinary excretion of albumin and {beta}{sub 2}-microglobulin was unchanged. However, urinary N-acetyl-{beta}-glucosaminidase and alkaline phosphatase increased significantly, most in the highest dose group. All changes were reversible. (orig.).

  4. Superhydrophobic hybrid membranes by grafting arc-like macromolecular bridges on graphene sheets: Synthesis, characterization and properties

    Science.gov (United States)

    Mo, Zhao-Hua; Luo, Zheng; Huang, Qiang; Deng, Jian-Ping; Wu, Yi-Xian

    2018-05-01

    Grafting single end-tethered polymer chains on the surface of graphene is a conventional way to modify the surface properties of graphene oxide. However, grafting arc-like macromolecular bridges on graphene surfaces has been barely reported. Herein, a novel arc-like polydimethylsiloxane (PDMS) macromolecular bridges grafted graphene sheets (GO-g-Arc PDMS) was successfully synthesized via a confined interface reaction at 90 °C. Both the hydrophilic α- and ω-amino groups of linear hydrophobic NH2-PDMS-NH2 macromolecular chains rapidly reacted with epoxy and carboxyl groups on the surfaces of graphene oxide in water suspension to form arc-like PDMS macromolecular bridges on graphene sheets. The grafting density of arc-like PDMS bridges on graphene sheets can reach up to 0.80 mmol g-1 or 1.32 arc-like bridges per nm2 by this confined interface reaction. The water contact angle (WCA) of the hybrid membrane could be increased with increasing both the grafting density and content of covalent arc-like bridges architecture. The superhydrophobic hybrid membrane with a WCA of 153.4° was prepared by grinding of the above arc-like PDMS bridges grafted graphene hybrid, dispersing in ethanol and filtrating by organic filter membrane. This superhydrophobic hybrid membrane shows good self-cleaning and complete oil-water separation properties, which provides potential applications in anticontamination coating and oil-water separation. To the best of our knowledge, this is the first report on the synthesis of functional hybrid membranes by grafting arc-like PDMS macromolecular bridges on graphene sheets via a confined interface reaction.

  5. A method for the investigation of cholegraphic contrast media

    International Nuclear Information System (INIS)

    Otto, H.

    1982-01-01

    Isolated perfused rat livers were used for investigating possible interactions between two simultaneously injected contrast media, and which technique, using parenteral application of cholegraphic media, is optimal. The results show that excretion of a parenteral contrast medium is reduced by giving an oral contrast medium at the same time. Simultaneous administration of two different contrast media therefore does not result in improved diagnostic information. The effect depends on the dose, and a sufficiently long interval should be observed between giving an oral and a parenteral contrast medium. A comparison of excretion values following injection of a bolus and prolonged infusion shows higher biliary contrast concentration and increased excretion after a single injection. Comparing only the period after the infusion, no difference was found between these two methods of administration. The single injection offers pharmacokinetic advantages, but an infusion is better tolerated and has fewer side effects. A rapid infusion of 10 to 15 minutes is therefore recommended as the optimal means of administration. (orig.) [de

  6. Myelography in achondroplasia: value of a lateral C1-2 puncture and non-ionic, water-soluble contrast medium

    International Nuclear Information System (INIS)

    Suss, R.A.; Udvarhelyi, G.B.; Wang, H.; Kumar, A.J.; Zinreich, S.J.; Rosenbaum, A.E.

    1983-01-01

    Because of technical difficulties and diagnostic limitations encountered with other myelographic techniques in patients with achondroplasia, the authors employed a lateral C1-2 puncture and non-ionic, water-soluble contrast medium in 18 achondroplastic patients with spinal compression (21 procedures). This technique proved most appropriate for identifying the upper limit of degenerative osteophytes causing exacerbation of congenital spinal stenosis, which is crucial in planning decompressive surgery. A potentially important additional finding was the presence of degenerative lower cervical spine disease in the majority of patients. There were no serious complications. The authors recommend this technique as safe and effective in achondroplastic patients with severe congenital spinal stenosis

  7. Systems and methods for separating particles utilizing engineered acoustic contrast capture particles

    Science.gov (United States)

    Kaduchak, Gregory; Ward, Michael D.

    2018-03-06

    An apparatus for separating particles from a medium includes a capillary defining a flow path therein that is in fluid communication with a medium source. The medium source includes engineered acoustic contrast capture particle having a predetermined acoustic contrast. The apparatus includes a vibration generator that is operable to produce at least one acoustic field within the flow path. The acoustic field produces a force potential minima for positive acoustic contrast particles and a force potential minima for negative acoustic contrast particles in the flow path and drives the engineered acoustic contrast capture particles to either the force potential minima for positive acoustic contrast particles or the force potential minima for negative acoustic contrast particles.

  8. Tuning the properties of an anthracene-based PPE-PPV copolymer by fine variation of its macromolecular parameters

    Czech Academy of Sciences Publication Activity Database

    Tinti, F.; Sabir, F. K.; Gazzano, M.; Righi, S.; Ulbricht, C.; Usluer, Ö.; Pokorná, Veronika; Cimrová, Věra; Yohannes, T.; Egbe, D. A. M.; Camaioni, N.

    2013-01-01

    Roč. 3, č. 19 (2013), s. 6972-6980 ISSN 2046-2069 R&D Projects: GA ČR GAP106/12/0827; GA ČR(CZ) GA13-26542S Institutional support: RVO:61389013 Keywords : anthracene-containing PPE-PPV copolymer * macromolecular parameters * structural and transport properties Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.708, year: 2013

  9. Intravenous Contrast Medium Administration for Computed Tomography Scan in Emergency: A Possible Cause of Contrast-Induced Nephropathy

    International Nuclear Information System (INIS)

    Sonhaye, Lantam; Kolou, Bérésa; Tchaou, Mazamaesso; Amadou, Abdoulatif; Assih, Kouméabalo; N'Timon, Bidamin; Adambounou, Kokou; Agoda-Koussema, Lama; Adjenou, Komlavi; N'Dakena, Koffi

    2015-01-01

    The goal of this study was to assess risk for CIN after CT Scan during an emergency and to identify risk factors for the patient. Prospective review of all patients admitted to the emergency room (ER) of the Teaching Hospital of Lomé (Togo) during a 2-year period. CIN was defined as an increase in serum creatinine by 0.5 mg/dL from admission after undergoing CT Scan with intravenous contrast. A total of 620 patients underwent a CT Scan in the emergency room using intravenous contrast and 672 patients took the CT Scan without intravenous contrast. Out of the patients who received intravenous contrast for CT Scan, three percent of them developed CIN during their admission. Moreover, upon discharge no patient had continued renal impairment. No patient required dialysis during their admission. The multivariate analysis of all patients who had serial creatinine levels (including those who did not receive any contrast load) shows no increased risk for acute kidney injury associated intravenous contrast (odds ratio = 0.619, p value = 0.886); only diabetes remains independent risk factor of acute kidney injury (odds ratio = 6.26, p value = 0.031)

  10. Speckle contrast diffuse correlation tomography of complex turbid medium flow

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chong; Irwin, Daniel; Lin, Yu; Shang, Yu; He, Lian; Kong, Weikai; Yu, Guoqiang [Department of Biomedical Engineering, University of Kentucky, Lexington, Kentucky 40506 (United States); Luo, Jia [Department of Pharmacology and Nutritional Sciences, University of Kentucky, Lexington, Kentucky 40506 (United States)

    2015-07-15

    Purpose: Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckle contrast diffuse correlation tomography (scDCT), enables incorporation of complex optical property heterogeneities and sample boundaries. When combined with a reflectance-based design, this system facilitates a rapid segue into flow contrast imaging of larger, in vivo applications such as humans. Methods: A highly sensitive CCD camera was integrated into a reflectance-based optical system. Four long-coherence laser source positions were coupled to an optical switch for sequencing of tomographic data acquisition providing multiple projections through the sample. This system was investigated through incorporation of liquid and solid tissue-like phantoms exhibiting optical properties and flow characteristics typical of human tissues. Computer simulations were also performed for comparisons. A uniquely encountered smear correction algorithm was employed to correct point-source illumination contributions during image capture with the frame-transfer CCD and reflectance setup. Results: Measurements with scDCT on a homogeneous liquid phantom showed that speckle contrast-based deep flow indices were within 12% of those from standard DCT. Inclusion of a solid phantom submerged below the liquid phantom surface allowed for heterogeneity detection and validation. The heterogeneity was identified successfully by reconstructed 3D flow contrast tomography with scDCT. The heterogeneity center and dimensions and averaged relative flow (within 3%) and localization were in agreement with actuality and computer simulations, respectively. Conclusions: A custom cost-effective CCD-based reflectance 3D flow imaging system demonstrated rapid acquisition of dense boundary

  11. MxCuBE: a synchrotron beamline control environment customized for macromolecular crystallography experiments

    International Nuclear Information System (INIS)

    Gabadinho, José; Beteva, Antonia; Guijarro, Matias; Rey-Bakaikoa, Vicente; Spruce, Darren

    2010-01-01

    MxCuBE is a beamline control environment optimized for the needs of macromolecular crystallography. This paper describes the design of the software and the features that MxCuBE currently provides. The design and features of a beamline control software system for macromolecular crystallography (MX) experiments developed at the European Synchrotron Radiation Facility (ESRF) are described. This system, MxCuBE, allows users to easily and simply interact with beamline hardware components and provides automated routines for common tasks in the operation of a synchrotron beamline dedicated to experiments in MX. Additional functionality is provided through intuitive interfaces that enable the assessment of the diffraction characteristics of samples, experiment planning, automatic data collection and the on-line collection and analysis of X-ray emission spectra. The software can be run in a tandem client-server mode that allows for remote control and relevant experimental parameters and results are automatically logged in a relational database, ISPyB. MxCuBE is modular, flexible and extensible and is currently deployed on eight macromolecular crystallography beamlines at the ESRF. Additionally, the software is installed at MAX-lab beamline I911-3 and at BESSY beamline BL14.1

  12. Intra-arterial digital subtraction portography with a blood-isotonic, non-ionic, dimeric contrast medium

    International Nuclear Information System (INIS)

    Minakuchi, Kazuo; Tamaoka, Koichi; Nishio, Hiroshi; Matsuo, Ryoichi; Takada, Keiji; Morimoto, Atsuko; Toyoshima, Masami; Murata, Katsuko; Onoyama, Yasuto

    1993-01-01

    Intra-arterial digital subtraction portography (IA-DSP) with a blood-isotonic, non-ionic, dimeric contrast medium was carried out in 27 patients with hepatocellular carcinoma. It was possible to obtain images of excellent or good quality of the portal vein and its bilateral main branches in all patients. The third-order branches of the portal vein in the right lobe could be identified in all patients, and images of excellent or good quality were obtained in a mean of 80.2% of patients. Images of third-order branches in the left lobe were of lower quality than those of third-order branches in the right lobe; in particular, images obtained were of poor quality for 27.3% of the medial branches of the left lobe. It was impossible to identify the caudal branches in almost all patients. The side effects of IA-DSP, pain and sensations of heat were very mild; only one patient complained of mild pain, while 18 patients (69.2%) complained of no sensations of heat whatsoever. (author)

  13. Comparison of two self-assembled macromolecular prodrug micelles with different conjugate positions of SN38 for enhancing antitumor activity

    Directory of Open Access Journals (Sweden)

    Liu Y

    2015-03-01

    Full Text Available Yi Liu,1 Hongyu Piao,1 Ying Gao,1 Caihong Xu,2 Ye Tian,1 Lihong Wang,1 Jinwen Liu,1 Bo Tang,1 Meijuan Zou,1 Gang Cheng1 1Department of Pharmaceutics, Shenyang Pharmaceutical University, Shenyang, Liaoning Province, People’s Republic of China; 2Department of Food Science, Shenyang Normal University, Shenyang, Liaoning Province, People’s Republic of China Abstract: 7-Ethyl-10-hydroxycamptothecin (SN38, an active metabolite of irinotecan (CPT-11, is a remarkably potent antitumor agent. The clinical application of SN38 has been extremely restricted by its insolubility in water. In this study, we successfully synthesized two macromolecular prodrugs of SN38 with different conjugate positions (chitosan-(C10-OHSN38 and chitosan-(C20-OHSN38 to improve the water solubility and antitumor activity of SN38. These prodrugs can self-assemble into micelles in aqueous medium. The particle size, morphology, zeta potential, and in vitro drug release of SN38 and its derivatives, as well as their cytotoxicity, pharmacokinetics, and in vivo antitumor activity in a xenograft BALB/c mouse model were studied. In vitro, chitosan-(C10-OHSN38 (CS-(10sSN38 and chitosan-(C20-OHSN38 (CS-(20sSN38 were 13.3- and 25.9-fold more potent than CPT-11 in the murine colon adenocarcinoma cell line CT26, respectively. The area under the curve (AUC0–24 of SN38 after intravenously administering CS-(10sSN38 and CS-(20sSN38 to Sprague Dawley rats was greatly improved when compared with CPT-11 (both P<0.01. A larger AUC0–24 of CS-(20sSN38 was observed when compared to CS-(10sSN38 (P<0.05. Both of the novel self-assembled chitosan-SN38 prodrugs demonstrated superior anticancer activity to CPT-11 in the CT26 xenograft BALB/c mouse model. We have also investigated the differences between these macromolecular prodrug micelles with regards to enhancing the antitumor activity of SN38. CS-(20sSN38 exhibited better in vivo antitumor activity than CS-(10sSN38 at a dose of 2.5 mg/kg (P<0

  14. Enzymes as Green Catalysts for Precision Macromolecular Synthesis.

    Science.gov (United States)

    Shoda, Shin-ichiro; Uyama, Hiroshi; Kadokawa, Jun-ichi; Kimura, Shunsaku; Kobayashi, Shiro

    2016-02-24

    The present article comprehensively reviews the macromolecular synthesis using enzymes as catalysts. Among the six main classes of enzymes, the three classes, oxidoreductases, transferases, and hydrolases, have been employed as catalysts for the in vitro macromolecular synthesis and modification reactions. Appropriate design of reaction including monomer and enzyme catalyst produces macromolecules with precisely controlled structure, similarly as in vivo enzymatic reactions. The reaction controls the product structure with respect to substrate selectivity, chemo-selectivity, regio-selectivity, stereoselectivity, and choro-selectivity. Oxidoreductases catalyze various oxidation polymerizations of aromatic compounds as well as vinyl polymerizations. Transferases are effective catalysts for producing polysaccharide having a variety of structure and polyesters. Hydrolases catalyzing the bond-cleaving of macromolecules in vivo, catalyze the reverse reaction for bond forming in vitro to give various polysaccharides and functionalized polyesters. The enzymatic polymerizations allowed the first in vitro synthesis of natural polysaccharides having complicated structures like cellulose, amylose, xylan, chitin, hyaluronan, and chondroitin. These polymerizations are "green" with several respects; nontoxicity of enzyme, high catalyst efficiency, selective reactions under mild conditions using green solvents and renewable starting materials, and producing minimal byproducts. Thus, the enzymatic polymerization is desirable for the environment and contributes to "green polymer chemistry" for maintaining sustainable society.

  15. Fluid Physics and Macromolecular Crystal Growth in Microgravity

    Science.gov (United States)

    Helliwell, John R.; Snell, Edward H.; Chayen, Naomi E.; Judge, Russell A.; Boggon, Titus J.; Pusey, M. L.; Rose, M. Franklin (Technical Monitor)

    2000-01-01

    The first protein crystallization experiment in microgravity was launched in April, 1981 and used Germany's Technologische Experimente unter Schwerelosigkeit (TEXUS 3) sounding rocket. The protein P-galactosidase (molecular weight 465Kda) was chosen as the sample with a liquid-liquid diffusion growth method. A sliding device brought the protein, buffer and salt solution into contact when microgravity was reached. The sounding rocket gave six minutes of microgravity time with a cine camera and schlieren optics used to monitor the experiment, a single growth cell. In microgravity a strictly laminar diffusion process was observed in contrast to the turbulent convection seen on the ground. Several single crystals, approx 100micron in length, were formed in the flight which were of inferior but of comparable visual quality to those grown on the ground over several days. A second experiment using the same protocol but with solutions cooled to -8C (kept liquid with glycerol antifreeze) again showed laminar diffusion. The science of macromolecular structural crystallography involves crystallization of the macromolecule followed by use of the crystal for X-ray diffraction experiments to determine the three dimensional structure of the macromolecule. Neutron protein crystallography is employed for elucidation of H/D exchange and for improved definition of the bound solvent (D20). The structural information enables an understanding of how the molecule functions with important potential for rational drug design, improved efficiency of industrial enzymes and agricultural chemical development. The removal of turbulent convection and sedimentation in microgravity, and the assumption that higher quality crystals will be produced, has given rise to the growing number of crystallization experiments now flown. Many experiments can be flown in a small volume with simple, largely automated, equipment - an ideal combination for a microgravity experiment. The term "protein crystal growth

  16. Atomic force microscopy applied to study macromolecular content of embedded biological material

    Energy Technology Data Exchange (ETDEWEB)

    Matsko, Nadejda B. [Electron Microscopy Centre, Institute of Applied Physics, HPM C 15.1, ETH-Hoenggerberg, CH-8093, Zurich (Switzerland)]. E-mail: matsko@iap.phys.ethz.ch

    2007-02-15

    We demonstrate that atomic force microscopy represents a powerful tool for the estimation of structural preservation of biological samples embedded in epoxy resin, in terms of their macromolecular distribution and architecture. The comparison of atomic force microscopy (AFM) and transmission electron microscopy (TEM) images of a biosample (Caenorhabditis elegans) prepared following to different types of freeze-substitution protocols (conventional OsO{sub 4} fixation, epoxy fixation) led to the conclusion that high TEM stainability of the sample results from a low macromolecular density of the cellular matrix. We propose a novel procedure aimed to obtain AFM and TEM images of the same particular organelle, which strongly facilitates AFM image interpretation and reveals new ultrastructural aspects (mainly protein arrangement) of a biosample in addition to TEM data.

  17. Effect of macromolecular crowding on the rate of diffusion-limited ...

    Indian Academy of Sciences (India)

    The enzymatic reaction rate has been shown to be affected by the presence of such macromolecules. A simple numerical model is proposed here based on percolation and diffusion in disordered systems to study the effect of macromolecular crowding on the enzymatic reaction rates. The model qualitatively explains some ...

  18. New Paradigm for Macromolecular Crystallography Experiments at SSRL: Automated Crystal Screening And Remote Data Collection

    International Nuclear Information System (INIS)

    Soltis, S.M.; Cohen, A.E.; Deacon, A.; Eriksson, T.; Gonzalez, A.; McPhillips, S.; Chui, H.; Dunten, P.; Hollenbeck, M.; Mathews, I.; Miller, M.; Moorhead, P.; Phizackerley, R.P.; Smith, C.; Song, J.; Bedem, H. van dem; Ellis, P.; Kuhn, P.; McPhillips, T.; Sauter, N.; Sharp, K.

    2009-01-01

    Complete automation of the macromolecular crystallography experiment has been achieved at Stanford Synchrotron Radiation Lightsource (SSRL) through the combination of robust mechanized experimental hardware and a flexible control system with an intuitive user interface. These highly reliable systems have enabled crystallography experiments to be carried out from the researchers' home institutions and other remote locations while retaining complete control over even the most challenging systems. A breakthrough component of the system, the Stanford Auto-Mounter (SAM), has enabled the efficient mounting of cryocooled samples without human intervention. Taking advantage of this automation, researchers have successfully screened more than 200 000 samples to select the crystals with the best diffraction quality for data collection as well as to determine optimal crystallization and cryocooling conditions. These systems, which have been deployed on all SSRL macromolecular crystallography beamlines and several beamlines worldwide, are used by more than 80 research groups in remote locations, establishing a new paradigm for macromolecular crystallography experimentation.

  19. In Vitro and In Vivo Evaluation of Microparticulate Drug Delivery Systems Composed of Macromolecular Prodrugs

    Directory of Open Access Journals (Sweden)

    Yoshiharu Machida

    2008-08-01

    Full Text Available Macromolecular prodrugs are very useful systems for achieving controlled drug release and drug targeting. In particular, various macromolecule-antitumor drug conjugates enhance the effectiveness and improve the toxic side effects. Also, polymeric micro- and nanoparticles have been actively examined and their in vivo behaviors elucidated, and it has been realized that their particle characteristics are very useful to control drug behavior. Recently, researches based on the combination of the concepts of macromolecular prodrugs and micro- or nanoparticles have been reported, although they are limited. Macromolecular prodrugs enable drugs to be released at a certain controlled release rate based on the features of the macromolecule-drug linkage. Micro- and nanoparticles can control in vivo behavior based on their size, surface charge and surface structure. These merits are expected for systems produced by the combination of each concept. In this review, several micro- or nanoparticles composed of macromolecule-drug conjugates are described for their preparation, in vitro properties and/or in vivo behavior.

  20. Influence of hyperosmotic agent (glycerol) in contrast enhancement

    International Nuclear Information System (INIS)

    Moriyama, Takashi; Suzuki, Shigeharu; Nakaoka, Tsutomu

    1981-01-01

    For getting a better contrast enhancement (CE) of computed tomography (CT) in brain tumors, we tried to increase the extravascular iodine concentration. A vailing ourselves of the period of returning water following intravenously administered glycerol, a drip injection of the contrast medium gave a better CE effect than the usual CE. In two benign gliomas, CE with glycerol was much better than CE without glycerol, and in two malignant gliomas and two metastatic tumors, CE with glycerol was better, but not so much better as with the benign tumors. In general, the CE effect in primary brain tumors showed a decreasing pattern, whereas in metastatic brain tumors the best time was 60 minutes after the injection of the contrast material (increasing and decreasing pattern), suggesting an increase in the extravascular iodine and a severe failure of the blood brain barrier. Two cystic malignant gliomas allowed the intravenously injected contrast medium to enter the cysts. It appears that the contrast medium passes through and/or is secreted from the wall of the cyst. (author)

  1. Potentials and limitations of low-concentration contrast medium (150 mg iodine/ml) in CT pulmonary angiography

    International Nuclear Information System (INIS)

    Radon, M.R.; Kaduthodil, M.J.; Jagdish, J.; Matthews, S.; Hill, C.; Bull, M.J.; Morcos, S.K.

    2011-01-01

    Aim: To assess the feasibility of producing diagnostic multidetector computed tomography (MDCT) pulmonary angiography with low iodine concentration contrast media (150 mg iodine/ml) in patients with suspected acute pulmonary embolism. Materials and methods: Ninety-five randomized patients underwent MDCT (64 row) pulmonary angiography with 100 ml iopromide either at low concentration (LC) of 150 mg iodine/ml (n = 45) or high concentration (HC) of 300 mg iodine/ml (n = 50), delivered at the rate of 5 ml/s via a power injector. Two experienced radiologists, blinded to the concentration used, subjectively assessed the diagnostic quality and confidence using a four-point scale [1 = poor (not diagnostic), 2 = satisfactory, 3 = good, 4 = excellent]. Attenuation values (in HU) were measured in the main proximal branches of the pulmonary arteries. Results: The median diagnostic quality score for both observers was 3.5 (interquartile range 3-4) in the HC group and 2.5 (interquartile range 1.5-3) in the LC group (p < 0.01). The median diagnostic confidence score for both observers was 4 (interquartile range 3-4) in the HC group and 3 (interquartile range 1.5-4) in the LC group (p < 0.01). Both observers rated examinations as diagnostic in 69% of cases in the LC group, compared with 96% of cases in the HC group. Good interobserver agreement was found in both groups (K value 0.72 in the LC group and 0.73 in the HC). Obesity, poor scan timing, and dilution by venous return of non-opacified blood were the main reasons for a reduction in diagnostic quality of examinations in the LC group. Conclusion: Despite a 50% reduction of contrast medium dose in comparison to the standard technique, 150 mg iodine/ml can produce diagnostic MDCT pulmonary angiogram studies in the absence of obesity or high cardiac output and hyper-dynamic pulmonary circulation. Reducing the dose of contrast media would minimize the risk of contrast nephropathy in patients at risk of this complication

  2. MR mammography: influence of menstrual cycle on the dynamic contrast enhancement of fibrocystic disease

    International Nuclear Information System (INIS)

    Rieber, A.; Nuessle, K.; Merkle, E.; Tomczak, R.; Brambs, H.J.; Kreienberg, R.

    1999-01-01

    Magnetic resonance mammography (MRM) provides data regarding the nature of tumours based on contrast medium dynamics; fibrocystic changes in the breast, however, may lead to false-positive results. This study investigated whether the contrast medium dynamics of fibrocystic changes are dependent on the menstrual cycle. Twenty-four patients with palpable lumps but normal mammographies and ultrasound studies were examined. The MRM technique was performed during the first and second part of the menstrual cycle using a FLASH 3D sequence, both native and at 1, 2, 3 and 8 min after intravenous application of 0.15 mmol/kg body weight of gadodiamide. The calculated time-intensity curves were evaluated based on the following criteria: early percentage of contrast medium uptake in relation to the native value; formation of a plateau phenomenon after the second minute; the point of maximal contrast medium uptake; and calculation of the contrast enhancing index. During the second half of the menstrual cycle, a generally greater contrast medium uptake was observed. Nevertheless, when further diagnostic criteria, such as continuous contrast medium increase as a function of time, were considered, there was no increased rate of false-positive findings. The phase of the menstrual cycle may affect the specificity of the examination, if only the quantitative contrast medium uptake and the percentage of contrast medium uptake in the first 2 min are considered. A control MRM during the other half of the cycle may then be indicated and additional diagnostic criteria may improve specificity. (orig.)

  3. MR mammography: influence of menstrual cycle on the dynamic contrast enhancement of fibrocystic disease

    Energy Technology Data Exchange (ETDEWEB)

    Rieber, A.; Nuessle, K.; Merkle, E.; Tomczak, R.; Brambs, H.J. [Ulm Univ. (Germany). Abt. Radiologie 1 (Roentgendiagnostik); Kreienberg, R. [Ulm Univ. (Germany). Dept. of Gynecology

    1999-08-01

    Magnetic resonance mammography (MRM) provides data regarding the nature of tumours based on contrast medium dynamics; fibrocystic changes in the breast, however, may lead to false-positive results. This study investigated whether the contrast medium dynamics of fibrocystic changes are dependent on the menstrual cycle. Twenty-four patients with palpable lumps but normal mammographies and ultrasound studies were examined. The MRM technique was performed during the first and second part of the menstrual cycle using a FLASH 3D sequence, both native and at 1, 2, 3 and 8 min after intravenous application of 0.15 mmol/kg body weight of gadodiamide. The calculated time-intensity curves were evaluated based on the following criteria: early percentage of contrast medium uptake in relation to the native value; formation of a plateau phenomenon after the second minute; the point of maximal contrast medium uptake; and calculation of the contrast enhancing index. During the second half of the menstrual cycle, a generally greater contrast medium uptake was observed. Nevertheless, when further diagnostic criteria, such as continuous contrast medium increase as a function of time, were considered, there was no increased rate of false-positive findings. The phase of the menstrual cycle may affect the specificity of the examination, if only the quantitative contrast medium uptake and the percentage of contrast medium uptake in the first 2 min are considered. A control MRM during the other half of the cycle may then be indicated and additional diagnostic criteria may improve specificity. (orig.) With 2 figs., 2 tabs., 24 refs.

  4. The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke

    International Nuclear Information System (INIS)

    Tijssen, M.P.M.; Stadler, A.A.R.; Zwam, W. van; Graaf, R. de; Postma, A.A.; Hofman, P.A.M.; Oostenbrugge, R.J. van; Klotz, E.; Wildberger, J.E.

    2014-01-01

    To assess the feasibility of dual energy computed tomography (DE-CT) in intra-arterially treated acute ischaemic stroke patients to discriminate between contrast extravasation and intracerebral haemorrhage. Thirty consecutive acute ischaemic stroke patients following intra-arterial treatment were examined with DE-CT. Simultaneous imaging at 80 kV and 140 kV was employed with calculation of mixed images. Virtual unenhanced non-contrast (VNC) images and iodine overlay maps (IOM) were calculated using a dedicated brain haemorrhage algorithm. Mixed images alone, as ''conventional CT'', and DE-CT interpretations were evaluated and compared with follow-up CT. Eight patients were excluded owing to a lack of follow-up or loss of data. Mixed images showed intracerebral hyperdense areas in 19/22 patients. Both haemorrhage and residual contrast material were present in 1/22. IOM suggested contrast extravasation in 18/22 patients; in 16/18 patients this was confirmed at follow-up. The positive predictive value (PPV) of mixed imaging alone was 25 %, with a negative predictive value (NPV) of 91 % and accuracy of 63 %. The PPV for detection of haemorrhage with DE-CT was 100 %, with an NPV of 89 % and accuracy improved to 89 %. Dual energy computed tomography improves accuracy and diagnostic confidence in early differentiation between intracranial haemorrhage and contrast medium extravasation in acute stroke patients following intra-arterial revascularisation. (orig.)

  5. The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Tijssen, M.P.M.; Stadler, A.A.R.; Zwam, W. van; Graaf, R. de; Postma, A.A. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Hofman, P.A.M. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University, MhENS School for Mental Health and Neuroscience, Maastricht (Netherlands); Oostenbrugge, R.J. van [Maastricht University Medical Centre, Department of Neurology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University, CARIM School for Cardiovascular Diseases, P.O. Box 616, Maastricht (Netherlands); Klotz, E. [Siemens Healthcare Sector, Computed Tomography, Forchheim (Germany); Wildberger, J.E. [Maastricht University Medical Centre, Department of Radiology, P.O. Box 5800, Maastricht (Netherlands); Maastricht University, CARIM School for Cardiovascular Diseases, P.O. Box 616, Maastricht (Netherlands)

    2014-04-15

    To assess the feasibility of dual energy computed tomography (DE-CT) in intra-arterially treated acute ischaemic stroke patients to discriminate between contrast extravasation and intracerebral haemorrhage. Thirty consecutive acute ischaemic stroke patients following intra-arterial treatment were examined with DE-CT. Simultaneous imaging at 80 kV and 140 kV was employed with calculation of mixed images. Virtual unenhanced non-contrast (VNC) images and iodine overlay maps (IOM) were calculated using a dedicated brain haemorrhage algorithm. Mixed images alone, as ''conventional CT'', and DE-CT interpretations were evaluated and compared with follow-up CT. Eight patients were excluded owing to a lack of follow-up or loss of data. Mixed images showed intracerebral hyperdense areas in 19/22 patients. Both haemorrhage and residual contrast material were present in 1/22. IOM suggested contrast extravasation in 18/22 patients; in 16/18 patients this was confirmed at follow-up. The positive predictive value (PPV) of mixed imaging alone was 25 %, with a negative predictive value (NPV) of 91 % and accuracy of 63 %. The PPV for detection of haemorrhage with DE-CT was 100 %, with an NPV of 89 % and accuracy improved to 89 %. Dual energy computed tomography improves accuracy and diagnostic confidence in early differentiation between intracranial haemorrhage and contrast medium extravasation in acute stroke patients following intra-arterial revascularisation. (orig.)

  6. Homogenization Theory for the Prediction of Obstructed Solute Diffusivity in Macromolecular Solutions.

    Science.gov (United States)

    Donovan, Preston; Chehreghanianzabi, Yasaman; Rathinam, Muruhan; Zustiak, Silviya Petrova

    2016-01-01

    The study of diffusion in macromolecular solutions is important in many biomedical applications such as separations, drug delivery, and cell encapsulation, and key for many biological processes such as protein assembly and interstitial transport. Not surprisingly, multiple models for the a-priori prediction of diffusion in macromolecular environments have been proposed. However, most models include parameters that are not readily measurable, are specific to the polymer-solute-solvent system, or are fitted and do not have a physical meaning. Here, for the first time, we develop a homogenization theory framework for the prediction of effective solute diffusivity in macromolecular environments based on physical parameters that are easily measurable and not specific to the macromolecule-solute-solvent system. Homogenization theory is useful for situations where knowledge of fine-scale parameters is used to predict bulk system behavior. As a first approximation, we focus on a model where the solute is subjected to obstructed diffusion via stationary spherical obstacles. We find that the homogenization theory results agree well with computationally more expensive Monte Carlo simulations. Moreover, the homogenization theory agrees with effective diffusivities of a solute in dilute and semi-dilute polymer solutions measured using fluorescence correlation spectroscopy. Lastly, we provide a mathematical formula for the effective diffusivity in terms of a non-dimensional and easily measurable geometric system parameter.

  7. Homogenization Theory for the Prediction of Obstructed Solute Diffusivity in Macromolecular Solutions.

    Directory of Open Access Journals (Sweden)

    Preston Donovan

    Full Text Available The study of diffusion in macromolecular solutions is important in many biomedical applications such as separations, drug delivery, and cell encapsulation, and key for many biological processes such as protein assembly and interstitial transport. Not surprisingly, multiple models for the a-priori prediction of diffusion in macromolecular environments have been proposed. However, most models include parameters that are not readily measurable, are specific to the polymer-solute-solvent system, or are fitted and do not have a physical meaning. Here, for the first time, we develop a homogenization theory framework for the prediction of effective solute diffusivity in macromolecular environments based on physical parameters that are easily measurable and not specific to the macromolecule-solute-solvent system. Homogenization theory is useful for situations where knowledge of fine-scale parameters is used to predict bulk system behavior. As a first approximation, we focus on a model where the solute is subjected to obstructed diffusion via stationary spherical obstacles. We find that the homogenization theory results agree well with computationally more expensive Monte Carlo simulations. Moreover, the homogenization theory agrees with effective diffusivities of a solute in dilute and semi-dilute polymer solutions measured using fluorescence correlation spectroscopy. Lastly, we provide a mathematical formula for the effective diffusivity in terms of a non-dimensional and easily measurable geometric system parameter.

  8. Quality of roentgenological visualization and tolerance of various intravenous cholegraphic contrast media

    International Nuclear Information System (INIS)

    Tischendorf, P.

    1980-01-01

    The recently introduced intravenous cholegraphic contrast media produce a greater diagnostic yield in radiological routine thanks to improved roentgenological contrasting. Whereas the percentage share of roentgenologically clearly assessable cases is about 75% when using Biligrafin, this percentage is much higher with the more recent contrast media, especially Biliscopin, namely, up to 88%. These new contrast media are also superior in respect of tolerance, since they produce fewer side effects. While side effects must be expected in about 28% of the cases when injecting Biligrafin, the side effect quota is about 10% only with Biliscopin or Endomirabil. If the contrast medium is infused instead of injected, the quota of side effect drops to 2.3% with Biliscopin or 3.9% with Endomirabil. Slight and medium side effects have definitely decreased with the more recent contrast media. The slower and more continually the contrast medium is administered, the fewer are the side effects observed; this becomes particularly noticeable in the case of long-term infusions. However, the likelihood of severe incidents caused by the contrast medium remains unchanged at about 1% of the examined patients, even with the more recently introduced contrast media. (orig.) [de

  9. PRIGo: a new multi-axis goniometer for macromolecular crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Waltersperger, Sandro; Olieric, Vincent, E-mail: vincent.olieric@psi.ch; Pradervand, Claude [Paul Scherrer Institute, Villigen PSI (Switzerland); Glettig, Wayne [Centre Suisse d’Electronique et Microtechnique SA, Neuchâtel 2002 (Switzerland); Salathe, Marco; Fuchs, Martin R.; Curtin, Adrian; Wang, Xiaoqiang; Ebner, Simon; Panepucci, Ezequiel; Weinert, Tobias [Paul Scherrer Institute, Villigen PSI (Switzerland); Schulze-Briese, Clemens [Dectris Ltd, Baden 5400 (Switzerland); Wang, Meitian, E-mail: vincent.olieric@psi.ch [Paul Scherrer Institute, Villigen PSI (Switzerland)

    2015-05-09

    The design and performance of the new multi-axis goniometer PRIGo developed at the Swiss Light Source at Paul Scherrer Institute is described. The Parallel Robotics Inspired Goniometer (PRIGo) is a novel compact and high-precision goniometer providing an alternative to (mini-)kappa, traditional three-circle goniometers and Eulerian cradles used for sample reorientation in macromolecular crystallography. Based on a combination of serial and parallel kinematics, PRIGo emulates an arc. It is mounted on an air-bearing stage for rotation around ω and consists of four linear positioners working synchronously to achieve x, y, z translations and χ rotation (0–90°), followed by a ϕ stage (0–360°) for rotation around the sample holder axis. Owing to the use of piezo linear positioners and active correction, PRIGo features spheres of confusion of <1 µm, <7 µm and <10 µm for ω, χ and ϕ, respectively, and is therefore very well suited for micro-crystallography. PRIGo enables optimal strategies for both native and experimental phasing crystallographic data collection. Herein, PRIGo hardware and software, its calibration, as well as applications in macromolecular crystallography are described.

  10. Progress in rational methods of cryoprotection in macromolecular crystallography

    International Nuclear Information System (INIS)

    Alcorn, Thomas; Juers, Douglas H.

    2010-01-01

    Measurements of the average thermal contractions (294→72 K) of 26 different cryosolutions are presented and discussed in conjunction with other recent advances in the rational design of protocols for cryogenic cooling in macromolecular crystallography. Cryogenic cooling of macromolecular crystals is commonly used for X-ray data collection both to reduce crystal damage from radiation and to gather functional information by cryogenically trapping intermediates. However, the cooling process can damage the crystals. Limiting cooling-induced crystal damage often requires cryoprotection strategies, which can involve substantial screening of solution conditions and cooling protocols. Here, recent developments directed towards rational methods for cryoprotection are described. Crystal damage is described in the context of the temperature response of the crystal as a thermodynamic system. As such, the internal and external parts of the crystal typically have different cryoprotection requirements. A key physical parameter, the thermal contraction, of 26 different cryoprotective solutions was measured between 294 and 72 K. The range of contractions was 2–13%, with the more polar cryosolutions contracting less. The potential uses of these results in the development of cryocooling conditions, as well as recent developments in determining minimum cryosolution soaking times, are discussed

  11. Saphenous Venous Ablation with Hot Contrast in a Canine Model

    International Nuclear Information System (INIS)

    Prasad, Amit; Qian Zhong; Kirsch, David; Eissa, Marna; Narra, Pavan; Lopera, Jorge; Espinoza, Carmen G.; Castaneda, Wifrido

    2008-01-01

    Purpose. To determine the feasibility, efficacy, and safety of thermal ablation of the saphenous vein with hot contrast medium. Methods. Twelve saphenous veins of 6 dogs were percutaneously ablated with hot contrast medium. In all animals, ablation was performed in the vein of one leg, followed by ablation in the contralateral side 1 month later. An occlusion balloon catheter was placed in the infragenicular segment of the saphenous vein via a jugular access to prevent unwanted thermal effects on the non-target segment of the saphenous vein. After inflation of the balloon, 10 ml of hot contrast medium was injected under fluoroscopic control through a sheath placed in the saphenous vein above the ankle. A second 10 ml injection of hot contrast medium was made after 5 min in each vessel. Venographic follow-up of the ablated veins was performed at 1 month (n = 12) and 2 months (n = 6). Results. Follow-up venograms showed that all ablated venous segments were occluded at 1 month. In 6 veins which were followed up to 2 months, 4 (66%) remained occluded, 1 (16%) was partially patent, and the remaining vein (16%) was completely patent. In these latter 2 cases, an inadequate amount of hot contrast was delivered to the lumen due to a closed balloon catheter downstream which did not allow contrast to displace blood within the vessel. Discussion. Hot contrast medium thermal ablation of the saphenous vein appears feasible, safe, and effective in the canine model, provided an adequate amount of embolization agent is used

  12. Collagen macromolecular drug delivery systems

    International Nuclear Information System (INIS)

    Gilbert, D.L.

    1988-01-01

    The objective of this study was to examine collagen for use as a macromolecular drug delivery system by determining the mechanism of release through a matrix. Collagen membranes varying in porosity, crosslinking density, structure and crosslinker were fabricated. Collagen characterized by infrared spectroscopy and solution viscosity was determined to be pure and native. The collagen membranes were determined to possess native vs. non-native quaternary structure and porous vs. dense aggregate membranes by electron microscopy. Collagen monolithic devices containing a model macromolecule (inulin) were fabricated. In vitro release rates were found to be linear with respect to t 1/2 and were affected by crosslinking density, crosslinker and structure. The biodegradation of the collagen matrix was also examined. In vivo biocompatibility, degradation and 14 C-inulin release rates were evaluated subcutaneously in rats

  13. Contrast media induced acute renal failure in diabetics

    International Nuclear Information System (INIS)

    Rambausek, M.

    1985-01-01

    Dehydration, preexisting renal insufficiency, multiple myeloma and insulin-dependent diabetes mellitus are known risk factors for a radiocontrast medium induced acute renal failure. In 90% of patients with insulin-dependent diabetes mellitus, renal insufficiency and proteinuria, a further detoriation of renal function can be expected after i.v. administration of radiocontrast medium. Recent concepts on the genesis of acute renal failure after radiocontrast medium in multiple myeloma emphasize the role of tubular blocade (tubular precipitation of myeloma protein with contrast medium). In insulin-dependent diabetic patients we found altered carbohydrate composition of urinary Tamm Horsfall Protein (THP), with increased glucose and diminished N-acetyl-neuraminicacid content. This was paralleled by a difference in an in-vitro system of coprecipitation where THP of diabetes triggered more pronounced calcium dependent coprecipitation of contrast medium and albumin. These in-vitro findings might be important for the explanation of the genesis of radiocontrast medium-induced acute renal failure in insulin-dependent diabetes mellitus. (orig.) [de

  14. Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver?

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Hiroto; Okada, Masahiro; Hyodo, Tomoko; Hidaka, Syojiro; Kagawa, Yuki; Matsuki, Mitsuru; Tsurusaki, Masakatsu; Murakami, Takamichi, E-mail: murakami@med.kindai.ac.jp

    2014-04-15

    Purpose: To investigate whether low-dose dynamic CT of the liver with iterative reconstruction can reduce both the radiation dose and the amount of contrast medium. Materials and methods: This study was approved by our institutional review board. 113 patients were randomly assigned to one of two groups. Group A/group B (fifty-eight/fifty-five patients) underwent liver dynamic CT at 120/100 kV, with 0/40% adaptive statistical iterative reconstruction (ASIR), with a contrast dose of 600/480 mg I/kg, respectively. Radiation exposure was estimated based on the manufacturer's phantom data. The enhancement value of the hepatic parenchyma, vessels and the tumor-to-liver contrast of hepatocellular carcinomas (HCCs) were compared between two groups. Two readers independently assessed the CT images of the hepatic parenchyma and HCCs. Results: The mean CT dose indices: 6.38/4.04 mGy, the dose-length products: 194.54/124.57 mGy cm, for group A/group B. The mean enhancement value of the hepatic parenchyma and the tumor-to-liver contrast of HCCs with diameters greater than 1 cm in the post-contrast all phases did not differ significantly between two groups (P > 0.05). The enhancement values of vessels in group B were significantly higher than that in group A in the delayed phases (P < 0.05). Two reader's confidence levels for the hepatic parenchyma in the delayed phases and HCCs did not differ significantly between the groups (P > 0.05). Conclusions: Low-dose dynamic CT with ASIR can reduce both the radiation dose and the amount of contrast medium without image quality degradation, compared to conventional dynamic CT without ASIR.

  15. 3D CT cerebral angiography technique using a 320-detector machine with a time–density curve and low contrast medium volume: Comparison with fixed time delay technique

    International Nuclear Information System (INIS)

    Das, K.; Biswas, S.; Roughley, S.; Bhojak, M.; Niven, S.

    2014-01-01

    Aim: To describe a cerebral computed tomography angiography (CTA) technique using a 320-detector CT machine and a small contrast medium volume (35 ml, 15 ml for test bolus). Also, to compare the quality of these images with that of the images acquired using a larger contrast medium volume (90 or 120 ml) and a fixed time delay (FTD) of 18 s using a 16-detector CT machine. Materials and methods: Cerebral CTA images were acquired using a 320-detector machine by synchronizing the scanning time with the time of peak enhancement as determined from the time–density curve (TDC) using a test bolus dose. The quality of CTA images acquired using this technique was compared with that obtained using a FTD of 18 s (by 16-detector CT), retrospectively. Average densities in four different intracranial arteries, overall opacification of arteries, and the degree of venous contamination were graded and compared. Results: Thirty-eight patients were scanned using the TDC technique and 40 patients using the FTD technique. The arterial densities achieved by the TDC technique were higher (significant for supraclinoid and basilar arteries, p < 0.05). The proportion of images deemed as having “good” arterial opacification was 95% for TDC and 90% for FTD. The degree of venous contamination was significantly higher in images produced by the FTD technique (p < 0.001%). Conclusion: Good diagnostic quality CTA images with significant reduction of venous contamination can be achieved with a low contrast medium dose using a 320-detector machine by coupling the time of data acquisition with the time of peak enhancement

  16. Data Management System at the Photon Factory Macromolecular Crystallography Beamline

    International Nuclear Information System (INIS)

    Yamada, Y; Matsugaki, N; Chavas, L M G; Hiraki, M; Igarashi, N; Wakatsuki, S

    2013-01-01

    Macromolecular crystallography is a very powerful tool to investigate three-dimensional structures of macromolecules at the atomic level, and is widely spread among structural biology researchers. Due to recent upgrades of the macromolecular crystallography beamlines at the Photon Factory, beamline throughput has improved, allowing more experiments to be conducted during a user's beam time. Although the number of beamlines has increased, so has the number of beam time applications. Consequently, both the experimental data from users' experiments and data derived from beamline operations have dramatically increased, causing difficulties in organizing these diverse and large amounts of data for the beamline operation staff and users. To overcome this problem, we have developed a data management system by introducing commercial middleware, which consists of a controller, database, and web servers. We have prepared several database projects using this system. Each project is dedicated to a certain aspect such as experimental results, beam time applications, beam time schedule, or beamline operation reports. Then we designed a scheme to link all the database projects.

  17. Comparison of neutral and positive enteral contrast media for MDCT enteroclysis

    International Nuclear Information System (INIS)

    Aiyappan, Senthil Kumar; Kalra, Naveen; Sandhu, Manavjit Singh; Kochhar, Rakesh; Wig, Jai Dev; Khandelwal, Niranjan

    2012-01-01

    Objective: To compare neutral and positive enteral contrast media for MDCT enteroclysis (MDCTE) in various small bowel diseases. Materials and methods: 40 patients with suspicion of small bowel diseases were divided randomly into two equal groups. In one group, water was used as neutral enteral contrast and in other group, 2% water soluble iodinated contrast was used as positive enteral contrast. All MDCTE were done on a 16-slice multidetector row CT unit. The findings of MDCTE were compared with the standards of reference. Results: There were 12 cases of abdominal tuberculosis (30%), 5 cases of bowel masses (12%), 4 cases of Crohn's disease (10%), 3 cases of small bowel adhesions (7%), 2 cases of midgut volvulus (5%), 2 cases of segmental enteritis (5%) and 12 of all cases (30%) were normal. There was no statistically significant difference between neutral and positive enteral contrast with regards to bowel distention, contrast reflux and evaluation of duodenum. Abnormal bowel wall enhancement was appreciated only with use of neutral enteral contrast (n = 12). Evaluation of ileocaecal junction was possible in all 20 patients (100%) with positive enteral contrast but in only 17 patients (85%) with neutral enteral contrast. Overall sensitivity and specificity of MDCTE with use of neutral contrast medium (100 and 88% respectively) was greater for evaluation of small bowel diseases, when compared to MDCTE using positive enteral contrast medium (92.8 and 83.3% respectively). Conclusions: Water is a good enteral contrast medium for MDCT enteroclysis examination and allows better evaluation of abnormal bowel wall enhancement. Ileocaecal junction evaluation is better with positive enteral contrast medium.

  18. Modeling the multi-scale mechanisms of macromolecular resource allocation

    DEFF Research Database (Denmark)

    Yang, Laurence; Yurkovich, James T; King, Zachary A

    2018-01-01

    As microbes face changing environments, they dynamically allocate macromolecular resources to produce a particular phenotypic state. Broad 'omics' data sets have revealed several interesting phenomena regarding how the proteome is allocated under differing conditions, but the functional consequen...... and detail how mathematical models have aided in our understanding of these processes. Ultimately, such modeling efforts have helped elucidate the principles of proteome allocation and hold promise for further discovery....

  19. Pi sampling: a methodical and flexible approach to initial macromolecular crystallization screening

    International Nuclear Information System (INIS)

    Gorrec, Fabrice; Palmer, Colin M.; Lebon, Guillaume; Warne, Tony

    2011-01-01

    Pi sampling, derived from the incomplete factorial approach, is an effort to maximize the diversity of macromolecular crystallization conditions and to facilitate the preparation of 96-condition initial screens. The Pi sampling method is derived from the incomplete factorial approach to macromolecular crystallization screen design. The resulting ‘Pi screens’ have a modular distribution of a given set of up to 36 stock solutions. Maximally diverse conditions can be produced by taking into account the properties of the chemicals used in the formulation and the concentrations of the corresponding solutions. The Pi sampling method has been implemented in a web-based application that generates screen formulations and recipes. It is particularly adapted to screens consisting of 96 different conditions. The flexibility and efficiency of Pi sampling is demonstrated by the crystallization of soluble proteins and of an integral membrane-protein sample

  20. Post double-contrast sigmoid flush: An adjuvant technique in imaging diverticular disease

    International Nuclear Information System (INIS)

    Lappas, J.C.; Maglinte, D.D.T.; Kopecky, K.K.; Cockerill, E.M.; Lehman, G.A.

    1987-01-01

    In a prospective study, the effect of a low-density contrast medium infusion was evaluated as an adjunct to high-density double-contrast medium sigmoid imaging. Following a double-contrast medium barium enema (DCBE), 52 consecutive patients with sigmoid diverticulosis received an additional 500-700-mL enema with either water or a 1.5%CT barium suspension. Rectosigmoid films were evaluated for luminal distention, visualization of the interhaustral space, definition of diverticula, and interpretation of polypoid defects. While double-contrast medium views were excellent in 21%, improvement in multiple factors by water or 1.5% barium flush resulted in improved sigmoid images in 65% and 73% of patients, respectively. Polyps may be confirmed and artifactual defects confidently excluded. Sigmoid flush, particularly with low-density barium, is a simple adjunct to DCBE that improves visualization of the diverticular sigmoid

  1. High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Knobloch, Gesine; Durmus, Tahir; Hamm, Bernd; Schwenke, Carsten; Huppertz, Alexander

    2014-01-01

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m 2 ) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G 30 , 30 mL; G 40 , 40 mL; G 50 , 50 mL; G 60 , 60 mL; G 70 , 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G 30 to 478.2 and 571.8 HU in G 70 . Mean attenuation values were higher in groups with higher CM volumes (P 30 , G 40 , G 50 , G 60 and G 70 were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. (orig.)

  2. Experimental investigations on the influence of the contrast medium Iopamiro 300 mixed with vegetal mucus on the nasolacrimal system and external eye tissues; Badania doswiadczalne nad wplywem srodka cieniujacego Iopamiro 300 ze sluzem roslinnym na drogi lzowe i przedni odcinek oka

    Energy Technology Data Exchange (ETDEWEB)

    Rubaj, B.; Koper, S. [Akademia Rolnicza, Lublin (Poland); Wolski, T.; Toczowski, J.; Wolski, J.; Langwinska-Wosko, E. [Akademia Medyczna, Lublin (Poland)

    1994-12-31

    Using low osmolality, nonionized contrast medium Iopamiro-300, Bracco mixed with the mucus prepared from the seed flax (``Linum usitatissimum, L.``), a dacryocistorhinography was performed experimentally on 8 healthy mongrel dogs. Assessing the occurrence of local and general complications was the aim of the investigation. On the basis of a radiographic examination it has been shown that the mixture of the contrast medium and seed flax mucus appeared to be a very useful compound for dacryocistorhinography, especially for the evaluation of nasolacrimal duct system course and its patency. Clinical observations and a histological examination proved that this compound of the contrast medium was well tolerated by the mucous membrane of the nasolacrimal system and the external eye tissues. (author). 21 refs, 4 figs.

  3. Digital subtraction angiography (DSA) of aortocoronary bypass grafts in the early postoperative phase with peripheral-venous contrast medium injection

    International Nuclear Information System (INIS)

    Tuengerthal, S.; Lang, J.; Donhoeffner, A.

    1985-01-01

    Using a fully digitalised subtraction unit, aortocoronary bypass grafts can be visualised in the early postoperative phase by means of peripheral venous contrast medium injection (57 out of a total of 60 cases). In more than one-half of the cases (31 out of a total of 60), it is possible to outline sharply the bypass grafts from the beginning to their entry into the bridged-over coronary artery, in such a manner that any loops, kinks, stenoses or reduced flow rates can be recognised. This examination is not considered to be an invasive one by the patient, and the cardiosurgeon can welcome it as a valuable additional means of controlling and assessing the results of surgery. (orig.) [de

  4. Hypersensitivity to contrast media and dyes.

    Science.gov (United States)

    Brockow, Knut; Sánchez-Borges, Mario

    2014-08-01

    This article updates current knowledge on hypersensitivity reactions to diagnostic contrast media and dyes. After application of a single iodinated radiocontrast medium (RCM), gadolinium-based contrast medium, fluorescein, or a blue dye, a hypersensitivity reaction is not a common finding; however, because of the high and still increasing frequency of those procedures, patients who have experienced severe reactions are nevertheless frequently encountered in allergy departments. Evidence on allergologic testing and management is best for iodinated RCM, limited for blue dyes, and insufficient for fluorescein. Skin tests can be helpful in the diagnosis of patients with hypersensitivity reactions to these compounds. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Functionalization of Planet-Satellite Nanostructures Revealed by Nanoscopic Localization of Distinct Macromolecular Species

    KAUST Repository

    Rossner, Christian; Roddatis, Vladimir; Lopatin, Sergei; Vana, Philipp

    2016-01-01

    The development of a straightforward method is reported to form hybrid polymer/gold planet-satellite nanostructures (PlSNs) with functional polymer. Polyacrylate type polymer with benzyl chloride in its backbone as a macromolecular tracer

  6. Contrast induced nephropathy in patients undergoing intravenous (IV) contrast enhanced computed tomography (CECT) and the relationship with risk factors: a meta-analysis

    NARCIS (Netherlands)

    Moos, Shira I.; van Vemde, David N. H.; Stoker, Jaap; Bipat, Shandra

    2013-01-01

    To summarize the incidence of contrast-induced nephropathy (CIN) and associations between CIN incidence and risk factors in patients undergoing intravenous contrast-enhanced computed tomography (CECT) with low- or iso-osmolar iodinated contrast medium. This review is performed in accordance with the

  7. Thiomers for oral delivery of hydrophilic macromolecular drugs.

    Science.gov (United States)

    Bernkop-Schnürch, Andreas; Hoffer, Martin H; Kafedjiiski, Krum

    2004-11-01

    In recent years thiolated polymers (thiomers) have appeared as a promising new tool in oral drug delivery. Thiomers are obtained by the immobilisation of thio-bearing ligands to mucoadhesive polymeric excipients. By the formation of disulfide bonds with mucus glycoproteins, the mucoadhesive properties of thiomers are up to 130-fold improved compared with the corresponding unmodified polymers. Owing to the formation of inter- and intramolecular disulfide bonds within the thiomer itself, matrix tablets and particulate delivery systems show strong cohesive properties, resulting in comparatively higher stability, prolonged disintegration times and a more controlled drug release. The permeation of hydrophilic macromolecular drugs through the gastrointestinal (GI) mucosa can be improved by the use of thiomers. Furthermore, some thiomers exhibit improved inhibitory properties towards GI peptidases. The efficacy of thiomers in oral drug delivery has been demonstrated by various in vivo studies. A pharmacological efficacy of 1%, for example, was achieved in rats by oral administration of calcitonin tablets comprising a thiomer. Furthermore, tablets comprising a thiomer and pegylated insulin resulted in a pharmacological efficacy of 7% after oral application to diabetic mice. Low-molecular-weight heparin embedded in thiolated polycarbophil led to an absolute bioavailability of > or = 20% after oral administration to rats. In these studies, formulations comprising the corresponding unmodified polymer had only a marginal or no effect. These results indicate drug carrier systems based on thiomers appear to be a promising tool for oral delivery of hydrophilic macromolecular drugs.

  8. ISPyB: an information management system for synchrotron macromolecular crystallography.

    Science.gov (United States)

    Delagenière, Solange; Brenchereau, Patrice; Launer, Ludovic; Ashton, Alun W; Leal, Ricardo; Veyrier, Stéphanie; Gabadinho, José; Gordon, Elspeth J; Jones, Samuel D; Levik, Karl Erik; McSweeney, Seán M; Monaco, Stéphanie; Nanao, Max; Spruce, Darren; Svensson, Olof; Walsh, Martin A; Leonard, Gordon A

    2011-11-15

    Individual research groups now analyze thousands of samples per year at synchrotron macromolecular crystallography (MX) resources. The efficient management of experimental data is thus essential if the best possible experiments are to be performed and the best possible data used in downstream processes in structure determination pipelines. Information System for Protein crystallography Beamlines (ISPyB), a Laboratory Information Management System (LIMS) with an underlying data model allowing for the integration of analyses down-stream of the data collection experiment was developed to facilitate such data management. ISPyB is now a multisite, generic LIMS for synchrotron-based MX experiments. Its initial functionality has been enhanced to include improved sample tracking and reporting of experimental protocols, the direct ranking of the diffraction characteristics of individual samples and the archiving of raw data and results from ancillary experiments and post-experiment data processing protocols. This latter feature paves the way for ISPyB to play a central role in future macromolecular structure solution pipelines and validates the application of the approach used in ISPyB to other experimental techniques, such as biological solution Small Angle X-ray Scattering and spectroscopy, which have similar sample tracking and data handling requirements.

  9. Macromolecular systems for vaccine delivery.

    Science.gov (United States)

    MuŽíková, G; Laga, R

    2016-10-20

    Vaccines have helped considerably in eliminating some life-threatening infectious diseases in past two hundred years. Recently, human medicine has focused on vaccination against some of the world's most common infectious diseases (AIDS, malaria, tuberculosis, etc.), and vaccination is also gaining popularity in the treatment of cancer or autoimmune diseases. The major limitation of current vaccines lies in their poor ability to generate a sufficient level of protective antibodies and T cell responses against diseases such as HIV, malaria, tuberculosis and cancers. Among the promising vaccination systems that could improve the potency of weakly immunogenic vaccines belong macromolecular carriers (water soluble polymers, polymer particels, micelles, gels etc.) conjugated with antigens and immunistumulatory molecules. The size, architecture, and the composition of the high molecular-weight carrier can significantly improve the vaccine efficiency. This review includes the most recently developed (bio)polymer-based vaccines reported in the literature.

  10. Physical experiments on the utility of non-iodine-containing contrast media

    International Nuclear Information System (INIS)

    Kirschner, H.; Burmester, U.; Stringaris, K.; Jentsch, F.

    1979-01-01

    Because of the excellent ability of the CT scanner in analyzing absorption, the use of non-iodine-containing contrast media will be discussed. Experimental studies of the chemical elements with the atomic number Z = 1-83 with a scan tension of 120 kV were made to determine how many atoms of a given element are necessary to replace one iodine atom in an iodine-containing contrast medium, whereby the same contrast enhancement in the scan picture as with the iodine-containing contrast medium is produced. (orig.) 891 ORU/orig. 892 MB [de

  11. Effect of ionic and non-ionic contrast media on whole blood viscosity, plasma viscosity and hematocrit in vitro

    International Nuclear Information System (INIS)

    Aspelin, P.

    1978-01-01

    The effect of the ionic contrast media diatrizoate, iocarmate and metrizoate and the non-ionic metrizamide on whole blood viscosity, plasma viscosity and hematocrit was investigated. All the contrast media increased whole blood and plasma viscosity and reduced the hematocrit. The whole blood viscosity increased with increasing osmolality of the contrast medium solutions, whereas the plasma viscosity increased with increasing viscosity of the contrast medium solutions. The higher the osmolality of the contrast media, the lower the hematocrit became. The normal shear-thinning (decreasing viscosity with increasing shear rate) property of blood was reduced when contrast medium was added to the blood. At 50 per cent volume ratio (contrast medium to blood), the ionic contrast media converted the blood into a shear-thickening (increasing viscosity with increasing shear rate) suspension, indicating a marked rigidification of the single red cell, while the non-ionic contrast medium still produced shear-thinning, indicating less rigidification of the red cell (p<0.01). (Auth.)

  12. Myths and misconceptions concerning contrast media-induced anaphylaxis: a narrative review.

    Science.gov (United States)

    Böhm, Ingrid; Morelli, John; Nairz, Knud; Silva Hasembank Keller, Patricia; Heverhagen, Johannes T

    2017-03-01

    Contrast-enhanced radiological examinations are an increasingly important diagnostic tool in modern medicine. All approved and available contrast media (iodinated and gadolinium-based) are safe compounds that are well-tolerated by most patients. However, a small percentage of patients exhibit contrast medium-induced adverse drug reactions that are dose-dependent and predictable (type A) or an even smaller cohort experience so-called type B (dose-independent, non-predictable). To increase patients' safety, recommendations/guidelines have been put forth in the literature and advice passed down informally by radiologists in practice to ensure contrast media safety. Through these, both reasonable suggestions as well as misinterpretations and myths (such as the misleading terms "allergy-like" reactions, and "iodine-allergy", the wrong assumption that the initial contact to a contrast medium could not induce an allergy, the estimation that an anti-allergy premedication could suppress all possible adverse reactions, and interleukin-2 as a risk/trigger for contrast medium adverse events) have arisen. Since the latter are not only unhelpful but also potentially reduce patients' safety, such myths and misconceptions are the focus of this review.

  13. Design, synthesis, and evaluation of VEGFR-targeted macromolecular MRI contrast agent based on biotin?avidin-specific binding

    OpenAIRE

    Liu, Yongjun; Wu, Xiaoyun; Sun, Xiaohe; Wang, Dan; Zhong, Ying; Jiang, Dandan; Wang, Tianqi; Yu, Dexin; Zhang, Na

    2017-01-01

    Yongjun Liu,1 Xiaoyun Wu,1 Xiaohe Sun,1 Dan Wang,1 Ying Zhong,1 Dandan Jiang,1 Tianqi Wang,1 Dexin Yu,2 Na Zhang1 1School of Pharmaceutical Science, Shandong University, 2Department of Radiology Medicine, Qilu Hospital, Jinan, People’s Republic of China Abstract: Developing magnetic resonance imaging (MRI) contrast agents with high relaxivity and specificity was essential to increase MRI diagnostic sensitivity and accuracy. In this study, the MRI contrast agent, vascular endotheli...

  14. Macromolecular composition of terrestrial and marine organic matter in sediments across the East Siberian Arctic Shelf

    Science.gov (United States)

    Sparkes, Robert B.; Doğrul Selver, Ayça; Gustafsson, Örjan; Semiletov, Igor P.; Haghipour, Negar; Wacker, Lukas; Eglinton, Timothy I.; Talbot, Helen M.; van Dongen, Bart E.

    2016-10-01

    Mobilisation of terrestrial organic carbon (terrOC) from permafrost environments in eastern Siberia has the potential to deliver significant amounts of carbon to the Arctic Ocean, via both fluvial and coastal erosion. Eroded terrOC can be degraded during offshore transport or deposited across the wide East Siberian Arctic Shelf (ESAS). Most studies of terrOC on the ESAS have concentrated on solvent-extractable organic matter, but this represents only a small proportion of the total terrOC load. In this study we have used pyrolysis-gas chromatography-mass spectrometry (py-GCMS) to study all major groups of macromolecular components of the terrOC; this is the first time that this technique has been applied to the ESAS. This has shown that there is a strong offshore trend from terrestrial phenols, aromatics and cyclopentenones to marine pyridines. There is good agreement between proportion phenols measured using py-GCMS and independent quantification of lignin phenol concentrations (r2 = 0.67, p radiocarbon data for bulk OC (14COC) which, when coupled with previous measurements, allows us to produce the most comprehensive 14COC map of the ESAS to date. Combining the 14COC and py-GCMS data suggests that the aromatics group of compounds is likely sourced from old, aged terrOC, in contrast to the phenols group, which is likely sourced from modern woody material. We propose that an index of the relative proportions of phenols and pyridines can be used as a novel terrestrial vs. marine proxy measurement for macromolecular organic matter. Principal component analysis found that various terrestrial vs. marine proxies show different patterns across the ESAS, and it shows that multiple river-ocean transects of surface sediments transition from river-dominated to coastal-erosion-dominated to marine-dominated signatures.

  15. Aspiration of Barium Contrast

    OpenAIRE

    Fuentes Santos, Cristina; Steen, Bárbara

    2014-01-01

    The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical fil...

  16. The Effect of Attractive Interactions and Macromolecular Crowding on Crystallins Association.

    Directory of Open Access Journals (Sweden)

    Jiachen Wei

    Full Text Available In living systems proteins are typically found in crowded environments where their effective interactions strongly depend on the surrounding medium. Yet, their association and dissociation needs to be robustly controlled in order to enable biological function. Uncontrolled protein aggregation often causes disease. For instance, cataract is caused by the clustering of lens proteins, i.e., crystallins, resulting in enhanced light scattering and impaired vision or blindness. To investigate the molecular origins of cataract formation and to design efficient treatments, a better understanding of crystallin association in macromolecular crowded environment is needed. Here we present a theoretical study of simple coarse grained colloidal models to characterize the general features of how the association equilibrium of proteins depends on the magnitude of intermolecular attraction. By comparing the analytic results to the available experimental data on the osmotic pressure in crystallin solutions, we identify the effective parameters regimes applicable to crystallins. Moreover, the combination of two models allows us to predict that the number of binding sites on crystallin is small, i.e. one to three per protein, which is different from previous estimates. We further observe that the crowding factor is sensitive to the size asymmetry between the reactants and crowding agents, the shape of the protein clusters, and to small variations of intermolecular attraction. Our work may provide general guidelines on how to steer the protein interactions in order to control their association.

  17. In-vacuum long-wavelength macromolecular crystallography.

    Science.gov (United States)

    Wagner, Armin; Duman, Ramona; Henderson, Keith; Mykhaylyk, Vitaliy

    2016-03-01

    Structure solution based on the weak anomalous signal from native (protein and DNA) crystals is increasingly being attempted as part of synchrotron experiments. Maximizing the measurable anomalous signal by collecting diffraction data at longer wavelengths presents a series of technical challenges caused by the increased absorption of X-rays and larger diffraction angles. A new beamline at Diamond Light Source has been built specifically for collecting data at wavelengths beyond the capability of other synchrotron macromolecular crystallography beamlines. Here, the theoretical considerations in support of the long-wavelength beamline are outlined and the in-vacuum design of the endstation is discussed, as well as other hardware features aimed at enhancing the accuracy of the diffraction data. The first commissioning results, representing the first in-vacuum protein structure solution, demonstrate the promising potential of the beamline.

  18. Use of postmortem coronary computed tomography angiography with water-insoluble contrast medium to detect stenosis of the left anterior descending artery in a case of sudden death.

    Science.gov (United States)

    Takahashi, Yoichiro; Sano, Rie; Takahashi, Keiko; Kominato, Yoshihiko; Takei, Hiroyuki; Kobayashi, Susumu; Shimada, Takehiro; Tokue, Hiroyuki; Awata, Sachiko; Hirasawa, Satoshi

    2016-03-01

    A 40-year-old man was found dead on a sidewalk in an expressway parking area one hour after he had entered the area on a motorcycle. A medicolegal autopsy was performed to reveal the cause of this sudden and unexpected death. Postmortem coronary CT angiography after introduction of 5% gelatin-barium emulsion as a radiopaque contrast medium into the heart demonstrated a significant arterial luminal filling defect in the left anterior descending (LAD) coronary artery. Macroscopic and microscopic examinations revealed that a thrombus had become deposited on ruptured plaque within the LAD artery, and that a small amount of the contrast medium was present between the thrombus and the vessel endothelium. These histological findings were consistent with incomplete occlusion of the LAD artery in the 3D reconstructed image. The cause of death in this case was definitively determined to be ischemic heart disease. Postmortem angiography played a role in screening of a vascular lesion that was subsequently verified by histology to have been responsible for sudden and unexpected death. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Visualization of endolymphatic hydrops in meniere's disease after single-dose intravenous gadolinium-based contrast medium. Timing of optimal enhancement

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Yamazaki, Masahiro; Kawai, Hisashi; Bokura, Kiminori; Sone, Michihiko; Nakashima, Tsutomu

    2012-01-01

    Visualization of endolymphatic hydrops (EH) in patients with Meniere's disease (MD) is now possible by heavily T 2 -weighted 3-dimensional fluid-attenuated inversion recovery (h T 2 W-3D-FLAIR) obtained 4 hours after intravenous (IV) administration of single dose gadolinium-based contrast medium (GBCM). Although maximum enhancement has been reported 4 hours after contrast administration in healthy volunteers, the timing of optimal enhancement in patients with MD is not reported. We investigated if that optimal timing is earlier or later than 4 hours. We evaluated 10 consecutive patients with suspected MD whom we randomly divided into 2 groups. We obtained h T 2 W-3D-FLAIR before GBCM administration and 10 min, 3.5 hours, and 4 hours after GBCM administration in Group A and before and 10 min, 4 hours, and 4.5 hours after GBCM administration in Group B. We compared signal intensity ratio (SIR) values of the perilymph and pons between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B and evaluated grades of EH at 3.5 and 4 hours in Group A and at 4 and 4.5 hours in Group B. SIR values did not differ significantly between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B. However, SIR values at 4 hours were significantly higher in Group A than Group B. Grades of EH agreed between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B. The optimal timing of contrast enhancement in patients with suspected MD remains unclear, but evaluation of EH may be possible from 3.5 to 4.5 hours after contrast administration. (author)

  20. Improved reproducibility of unit-cell parameters in macromolecular cryocrystallography by limiting dehydration during crystal mounting.

    Science.gov (United States)

    Farley, Christopher; Burks, Geoffry; Siegert, Thomas; Juers, Douglas H

    2014-08-01

    In macromolecular cryocrystallography unit-cell parameters can have low reproducibility, limiting the effectiveness of combining data sets from multiple crystals and inhibiting the development of defined repeatable cooling protocols. Here, potential sources of unit-cell variation are investigated and crystal dehydration during loop-mounting is found to be an important factor. The amount of water lost by the unit cell depends on the crystal size, the loop size, the ambient relative humidity and the transfer distance to the cooling medium. To limit water loss during crystal mounting, a threefold strategy has been implemented. Firstly, crystal manipulations are performed in a humid environment similar to the humidity of the crystal-growth or soaking solution. Secondly, the looped crystal is transferred to a vial containing a small amount of the crystal soaking solution. Upon loop transfer, the vial is sealed, which allows transport of the crystal at its equilibrated humidity. Thirdly, the crystal loop is directly mounted from the vial into the cold gas stream. This strategy minimizes the exposure of the crystal to relatively low humidity ambient air, improves the reproducibility of low-temperature unit-cell parameters and offers some new approaches to crystal handling and cryoprotection.

  1. Contrast detail phantom for SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Cabrejas, M.L. de; Arashiro, J G; Giannone, C. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Camuyrano, M; Nohara, G [Universidad de Buenos Aires, Buenos Aires (Argentina). Facultad Ciencias Exactas

    1996-06-01

    A new low variable contrast phantom for single photon emission computed tomography (SPECT) was constructed, tested and compared with other existing phantoms. It contains simulated cylindrical lesions of four different diameters (D{sub i}), embedded in a cylindrical scattering medium and a uniform section to evaluate tomographic uniformity. The concentration of tracer in the simulated lesions and the scattering medium (background) can be varied to simulate hot and cold lesions. Different applications of the phantom were tested, including determination of the minimum object contrast (OCm) necessary to detect lesions as a function of lesion size, lesion type (hot or cold) and acquisition and processing protocols by visual inspection. This parameter allows categorization of instruments comparing an `image quality index` (IQI). Preliminary comparison with the Britten contrast processing method showed that the detectable OCm was of the same order of magnitude, but the presented device seems more suitable for training and intercomparison purposes. The constructed phantom, of simple design, has proved to be useful for acquisition and processing condition evaluation, OCm estimation and external quality control. (author). 11 refs, 4 figs.

  2. Design, synthesis, and evaluation of VEGFR-targeted macromolecular MRI contrast agent based on biotin-avidin-specific binding.

    Science.gov (United States)

    Liu, Yongjun; Wu, Xiaoyun; Sun, Xiaohe; Wang, Dan; Zhong, Ying; Jiang, Dandan; Wang, Tianqi; Yu, Dexin; Zhang, Na

    2017-01-01

    Developing magnetic resonance imaging (MRI) contrast agents with high relaxivity and specificity was essential to increase MRI diagnostic sensitivity and accuracy. In this study, the MRI contrast agent, vascular endothelial growth factor receptor (VEGFR)-targeted poly (l-lysine) (PLL)-diethylene triamine pentacetate acid (DTPA)-gadolinium (Gd) (VEGFR-targeted PLL-DTPA-Gd, VPDG), was designed and prepared to enhance the MRI diagnosis capacity of tumor. Biotin-PLL-DTPA-Gd was synthesized first, then, VEGFR antibody was linked to biotin-PLL-DTPA-Gd using biotin-avidin reaction. In vitro cytotoxicity study results showed that VPDG had low toxicity to MCF-7 cells and HepG2 cells at experimental concentrations. In cell uptake experiments, VPDG could significantly increase the internalization rates (61.75%±5.22%) in VEGFR-positive HepG2 cells compared to PLL-DTPA-Gd (PDG) (25.16%±4.71%, P contrast agent and held great potential for molecular diagnosis of tumor.

  3. Long-term results with a nonionic contrast medium - a clinical experience report

    International Nuclear Information System (INIS)

    Hruby, W.; Stellamor, K.

    1987-01-01

    Between January 1982 and May 1986 more than 50 000 patients were examined radioligically with water-soluble (ionic and nonionic) contrast media at the Department of Radiology Rudolfstiftung, Vienna. 1983 only 2,2% of the contrast agents used were nonionic, in 1985 the share had increased to 53,3%. During this period the rate of drug-related side effects (DRSE) decreased from 6,9% (1983) to 3,3% (1985). From 1983 to 1985 DRSE were observed with 1952 patients after administration of ionic agents, whereas after application of nonionic media adverse reactions occurred in only 6 cases, so that DRSE rates of 6,98% respectively 0,07% resulted for ionic respectively nonionic contrast media. These results are discussed with regard to the physicochemical properties and physiological actions of ionic and nonionic contrast agents. (orig.) [de

  4. Investigation of the gastrointestinal tract by means of the first dimerous nonionic x-ray contrast medium (Iotrolan)

    International Nuclear Information System (INIS)

    Troger, J.; Wenzel-Hora, B.I.

    1987-01-01

    The risks with an ionic, water solvent highly osmotic contrast medium (CM) have now led to a monomerous, nonionic CM being used, particularly in the field of gastrointestinal investigation in newborn babies and infants. Thus side effects could be reduced and the quality of the x-rays improved. However, since the monomerous nonionic CM is still hyperosmotic with respect to blood, there is a water shift into the intestinal lumen. This can upset hydration and impair the quality of radiographs. Iotrolan is the first CM isoosmotic to the blood to be used clinically. It has proved to be superior to a monomerous nonionic CM as far as radiographic quality (density and sharpness) is concerned. Fifty-one children, aged 2 days to 19 years, were give Iotrolan. Some of these patients were compared in a double-blind study with a group of children who had been given monomerous nonionic CM. If Iotrolan was given, the good quality of the radiographs remained constant throughout the gastrointestinal tract and details were clearly discernible, even in the rectum. In addition, Iotrolan in the aboral intestinal sections leads to double-contrast pictures and thereby further increases the identifiability of details. The monomerous nonionic CM, however, showed a loss in density and above all in sharpness during its passage. Since Iotrolan is isotonic to blood, its is superior to all other water-solvent CM as far as possible side effects and radiographic quality are concerned

  5. Effects of age and brightness contrast on perception of the Wundt-Hering illusion.

    Science.gov (United States)

    Astor-Stetson, E; Purnell, T G

    1990-10-01

    Susceptibility to the Wundt-Hering illusion was studied as a function of age and contrast. Preschoolers, third-graders and college students were shown light-grey, medium-grey, and black Wundt-Hering figures on white ground. Pre-schoolers were most susceptible to the illusion, differing from third graders in the medium and high contrast conditions and from college students in all contrast conditions. Low contrast figures resulted in significantly less distortion than did high contrast figures for the preschoolers. The significant interaction of age and contrast effects highlights the importance of a developmental approach to the study of illusions.

  6. MRI cisternography with gadolinium-containing contrast medium: its role, advantages and limitations in the investigation of rhinorrhoea.

    Science.gov (United States)

    Aydin, K; Guven, K; Sencer, S; Jinkins, J R; Minareci, O

    2004-01-01

    Our purpose was to evaluate the utility of intrathecal gadopentetate dimeglumine -enhanced magnetic resonance cisternography (GdMRC). We injected 0.5 ml contrast medium into the subarachnoid space via lumbar puncture in 20 patients with suspected cerebrospinal fluid (CSF) rhinorrhoea. MRC showed CSF leakage in 14 patients with rhinorrhoea at the time of the examination, into the ethmoid air cells in nine, the sphenoid sinus in three and the frontal sinus in two cases. In 12 of these the site leakage was confirmed during surgical repair of the fistula. No leakage was observed in four patients with intermittent rhinorrhoea, not present at the time of the examination. GdMRC showed leakage in two patients with negative CT cisternography. GdMRC may prove better than CT cisternography, especially with slow CSF flow. We also showed low-dose GdMRC to be a feasible and relative safe way of confirming the presence of and localising active CSF leaks prior to surgical repair.

  7. MRI cisternography with gadolinium-containing contrast medium: its role, advantages and limitations in the investigation of rhinorrhoea

    International Nuclear Information System (INIS)

    Aydin, K.; Guven, K.; Sencer, S.; Minareci, O.; Jinkins, J.R.

    2004-01-01

    Our purpose was to evaluate the utility of intrathecal gadopentetate dimeglumine -enhanced magnetic resonance cisternography (GdMRC). We injected 0.5 ml contrast medium into the subarachnoid space via lumbar puncture in 20 patients with suspected cerebrospinal fluid (CSF) rhinorrhoea. MRC showed CSF leakage in 14 patients with rhinorrhoea at the time of the examination, into the ethmoid air cells in nine, the sphenoid sinus in three and the frontal sinus in two cases. In 12 of these the site leakage was confirmed during surgical repair of the fistula. No leakage was observed in four patients with intermittent rhinorrhoea, not present at the time of the examination. GdMRC showed leakage in two patients with negative CT cisternography. GdMRC may prove better than CT cisternography, especially with slow CSF flow. We also showed low-dose GdMRC to be a feasible and relative safe way of confirming the presence of and localising active CSF leaks prior to surgical repair. (orig.)

  8. Workshop on algorithms for macromolecular modeling. Final project report, June 1, 1994--May 31, 1995

    Energy Technology Data Exchange (ETDEWEB)

    Leimkuhler, B.; Hermans, J.; Skeel, R.D.

    1995-07-01

    A workshop was held on algorithms and parallel implementations for macromolecular dynamics, protein folding, and structural refinement. This document contains abstracts and brief reports from that workshop.

  9. Transient global amnesia following cerebral angiography with non-ionic contrast medium

    International Nuclear Information System (INIS)

    Schamschula, R.G.; Soo, M.Y.S.

    1994-01-01

    Transit global amnesia (TGA) is an uncommon syndrome of recent memory deficit and inability to learn new data, usually resolving within 24 hours. Two cases following use of non-ionic contrast media in cerebral angiography are presented. The neuroanatomy of memory is reviewed. Possible aetiologies of TGA in relation to cerebral angiography include ischemia (embolic, arterial spasm), epilepsy that may be primary or tumour-related and direct toxic effects of contrast media. 19 refs., 1 fig

  10. Aging changes of macromolecular synthesis in the mitochondria of mouse hepatocytes as revealed by microscopic radioautography

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Tetsuji [Shinshu University, Matsumoto (Japan). Dept. of Anatomy and Cell Biology

    2007-07-01

    This mini-review reports aging changes of macromolecular synthesis in the mitochondria of mouse hepatocytes. We have observed the macromolecular synthesis, such as DNA, RNA and proteins, in the mitochondria of various mammalian cells by means of electron microscopic radioautography technique developed in our laboratory. The number of mitochondria per cell, number of labeled mitochondria per cell with 3H-thymidine, 3H-uridine and 3H-leucine, precursors for DNA, RNA and proteins, respectively, were counted and the labeling indices at various ages, from fetal to postnatal early days and several months to 1 and 2 years in senescence, were calculated, which showed variations due to aging. (author)

  11. Variable effects of radiological contrast media on thrombus growth in a rabbit jugular vein thrombosis model

    NARCIS (Netherlands)

    Levi, M. [=Marcel M.; Biemond, B. J.; Sturk, A.; Hoek, J.; ten Cate, J. W.

    1991-01-01

    We studied the effect of an ionic high osmolar contrast medium (Ioxitalamate), an ionic low osmolar contrast medium (Ioxaglate) and various nonionic low osmolar contrast media (Iopamidol, Iopromide and Iohexol) on thrombus growth in a rabbit jugular vein thrombosis model. Thrombus growth was

  12. A finite-difference contrast source inversion method

    International Nuclear Information System (INIS)

    Abubakar, A; Hu, W; Habashy, T M; Van den Berg, P M

    2008-01-01

    We present a contrast source inversion (CSI) algorithm using a finite-difference (FD) approach as its backbone for reconstructing the unknown material properties of inhomogeneous objects embedded in a known inhomogeneous background medium. Unlike the CSI method using the integral equation (IE) approach, the FD-CSI method can readily employ an arbitrary inhomogeneous medium as its background. The ability to use an inhomogeneous background medium has made this algorithm very suitable to be used in through-wall imaging and time-lapse inversion applications. Similar to the IE-CSI algorithm the unknown contrast sources and contrast function are updated alternately to reconstruct the unknown objects without requiring the solution of the full forward problem at each iteration step in the optimization process. The FD solver is formulated in the frequency domain and it is equipped with a perfectly matched layer (PML) absorbing boundary condition. The FD operator used in the FD-CSI method is only dependent on the background medium and the frequency of operation, thus it does not change throughout the inversion process. Therefore, at least for the two-dimensional (2D) configurations, where the size of the stiffness matrix is manageable, the FD stiffness matrix can be inverted using a non-iterative inversion matrix approach such as a Gauss elimination method for the sparse matrix. In this case, an LU decomposition needs to be done only once and can then be reused for multiple source positions and in successive iterations of the inversion. Numerical experiments show that this FD-CSI algorithm has an excellent performance for inverting inhomogeneous objects embedded in an inhomogeneous background medium

  13. Organizational liability for adverse reactions to the contrast media

    International Nuclear Information System (INIS)

    Lim, Chang Seon

    2007-01-01

    Contrast medium is a very useful tool for X-ray examinations. But contrast medium has some unavoidable adverse reactions. For those patients who have never received contrast medium before, it is impossible to predict whether they will suffer from certain kinds of adverse reactions. Thus, radiologists should use strategies to minimize adverse events and be prepared to promptly recognize and manage any reactions to the contrast media. If a radiologist commits medical malpractice, he will face civil responsibility. Medical malpractice means a tort or breach of contrast that occurs in a medical setting. Medical malpractices happen, despite the efforts of hospital staff. Many courts have applied the traditional doctrine of respondeat superior in actions against organizations for injuries caused by their employees. It is a legal doctrine, which states that an employer is responsible for employee actions performed within the course of the employment. A hospital is an organization for health purposes. An organization may be convicted of an offense committed by an employee of the organization acting in its behalf and within the scope of this office or employment. Organizational liability involves a wide variety of legal issues, including tort liability, wrongful employment practices, personal injury, breach of fiduciary duty, and so on. Many executive directors of organizations are aware of their personal and organizational risks of exposure to legal liabilities. The employer must have the right to control the physical conduct of the employee and must consent to receive the employee's services, while expecting some benefits from the services offered. Therefore, legal liability can be imposed for improper selection, assignment, training, and supervision of employees. In conclusion, the hospital itself has organizational liability for adverse reactions to the contrast medium

  14. FOLD-EM: automated fold recognition in medium- and low-resolution (4-15 Å) electron density maps.

    Science.gov (United States)

    Saha, Mitul; Morais, Marc C

    2012-12-15

    Owing to the size and complexity of large multi-component biological assemblies, the most tractable approach to determining their atomic structure is often to fit high-resolution radiographic or nuclear magnetic resonance structures of isolated components into lower resolution electron density maps of the larger assembly obtained using cryo-electron microscopy (cryo-EM). This hybrid approach to structure determination requires that an atomic resolution structure of each component, or a suitable homolog, is available. If neither is available, then the amount of structural information regarding that component is limited by the resolution of the cryo-EM map. However, even if a suitable homolog cannot be identified using sequence analysis, a search for structural homologs should still be performed because structural homology often persists throughout evolution even when sequence homology is undetectable, As macromolecules can often be described as a collection of independently folded domains, one way of searching for structural homologs would be to systematically fit representative domain structures from a protein domain database into the medium/low resolution cryo-EM map and return the best fits. Taken together, the best fitting non-overlapping structures would constitute a 'mosaic' backbone model of the assembly that could aid map interpretation and illuminate biological function. Using the computational principles of the Scale-Invariant Feature Transform (SIFT), we have developed FOLD-EM-a computational tool that can identify folded macromolecular domains in medium to low resolution (4-15 Å) electron density maps and return a model of the constituent polypeptides in a fully automated fashion. As a by-product, FOLD-EM can also do flexible multi-domain fitting that may provide insight into conformational changes that occur in macromolecular assemblies.

  15. High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Lembcke, Alexander; Hein, Patrick A.; Knobloch, Gesine; Durmus, Tahir; Hamm, Bernd [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); Schwenke, Carsten [SCO:SSiS - Schwenke Consulting, Berlin (Germany); Huppertz, Alexander [Charite - University Medicine Berlin, Department of Radiology, Berlin (Germany); ISI - Imaging Science Institute Charite, Berlin (Germany)

    2014-01-15

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m{sup 2}) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G{sub 30}, 30 mL; G{sub 40}, 40 mL; G{sub 50}, 50 mL; G{sub 60}, 60 mL; G{sub 70}, 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G{sub 30} to 478.2 and 571.8 HU in G{sub 70}. Mean attenuation values were higher in groups with higher CM volumes (P < 0.0001) and higher in women than in men (P < 0.0001). The proportions of segments with attenuation of at least 300 HU in G{sub 30}, G{sub 40}, G{sub 50}, G{sub 60} and G{sub 70} were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. (orig.)

  16. Improvements in gastric diagnosis by using high density contrast media with low viscosity

    International Nuclear Information System (INIS)

    Toischer, H.P.

    1983-01-01

    In a retrospective clinical study, 150 unselected double contrast examinations of the stomach using conventional contrast media (100 g/100 ml barium sulphate) were compared with a similar number of examinations using a high density contrast medium of flow viscosity (250 g/100 ml barium sulphate). The high density contrast medium was distinctly better for demonstrating detail of the gastric mucosa. The uneveness of coating and instability of the older high density contrast media was observed in 15.5% of cases and, in no instance, did this make it impossible to reach a diagnosis. (orig.) [de

  17. Experimental irradiation of the rat ureter: The effects of field size and the presence of contrast medium on incidence and latency of hydronephrosis

    International Nuclear Information System (INIS)

    Knowles, J.F.; Trott, K.R.

    1987-01-01

    Following X-irradiation of a 1.5 cm length of rat ureter, hydronephrosis developed after doses down to 10 Gy. The estimated ED 50 was 11.8 Gy. In the dose range 37.4 Gy to 17.5 Gy there was a significant increase in latency with decreasing dose, but at lower doses the latency did not increase further. Reducing the length of ureter irradiated to 0.5 cm or 0.8 cm caused a decrease in incidence of hydronephrosis and longer latency periods. The ED 50 for rats iradiated to 0.5 cm of ureter was 29.6 Gy. The possibility that secondary radiation produced as a result of interaction between X-radiation and iodinated contrast medium might affect the radiation induction of hydronephrosis was investigated. No difference was found between groups of rats irradiated with or without injection of contrast media. 39 refs.; 4 figs

  18. Use of cystatin C and serum creatinine for the diagnosis of contrast-induced nephropathy in patients undergoing contrast-enhanced computed tomography at an oncology centre.

    Directory of Open Access Journals (Sweden)

    Joao Italo Fortalesa Melo

    Full Text Available Our aim was to assess renal function using as laboratory measurements serum creatinine and cystatin C concentrations before and after administration of low-osmolarity (nonionic iodinated contrast medium in patients with cancer undergoing computed tomography (CT.This prospective study included 400 oncologic outpatients. Serum creatinine and cystatin C concentrations were measured before and 72 h after contrast administration. Glomerular filtration rates (GFRs were estimated using serum creatinine-based [Modification of Diet in Renal Disease (MDRD and Cockroft-Gault and cystatin C based (Larsson equations. Exploratory data analysis was performed. The nonparametric Wilcoxon test was used to compare pre and post contrast of test results and estimated clearance. The confidence interval used in the analysis was 95%.Compared with the pre-contrast values, the mean serum creatinine concentration was significantly higher and average GFRs estimated using MDRD and Cockcroft-Gault equations were significantly lower after the administration of contrast (p <0.001. It was also observed a significant increase after contrast in the concentration of Cystatin C (p = 0.015. In addition, a decrease in GFR estimated using the average Larsson (p = 0.021 was observed between time points. However, none of the patients presented clinically significant nephropathy.Assessment using serum creatinine and cystatin C concentrations showed changes in renal function among patients with cancer undergoing contrast-enhanced CT examination in this study. No significant renal damage related to the use of low-osmolarity iodinated contrast medium of the type and dosage employed in this study was observed. This contrast medium is thus safe for use in patients with cancer.

  19. Transient angioedema of small bowel secondary to intravenous iodinated contrast medium

    Directory of Open Access Journals (Sweden)

    Kirankumar N Kulkarni

    2014-01-01

    Full Text Available We report the clinical details and imaging findings of a case of transient angioedema of the small bowel following intravenous administration of non-ionic iodinated contrast material in a 17 year old female with no predisposing risk factors. Findings included long segment, symmetric, circumferential, low-density, bowel wall thickening involving the duodenum, jejunum, and most of the ileum on computed tomography scan obtained at 7 min following intravenous contrast material injection. This entity is self-limiting with a favourable clinical outcome and requires no specific treatment but only aggressive clinical monitoring.

  20. MRI monitoring of tumor response following angiogenesis inhibition in an experimental human breast cancer model

    International Nuclear Information System (INIS)

    Turetschek, Karl; Preda, Anda; Shames, David M.; Novikov, Viktor; Roberts, Timothy P.L.; Fu, Yanjun; Brasch, Robert C.; Floyd, Eugenia; Carter, Wayne O.; Wood, Jeanette M.

    2003-01-01

    The aim of this study was to evaluate the potential of dynamic magnetic resonance imaging (MRI) enhanced by macromolecular contrast agents to monitor noninvasively the therapeutic effect of an anti-angiogenesis VEGF receptor kinase inhibitor in an experimental cancer model. MDA-MB-435, a poorly differentiated human breast cancer cell line, was implanted into the mammary fat pad in 20 female homozygous athymic rats. Animals were assigned randomly to a control (n=10) or drug treatment group (n=10). Baseline dynamic MRI was performed on sequential days using albumin-(GdDTPA) 30 (6.0 nm diameter) and ultrasmall superparamagnetic iron oxide (USPIO) particles (30 nm diameter). Subjects were treated either with PTK787/ZK 222584, a VEGF receptor tyrosine kinase inhibitor, or saline given orally twice daily for 1 week followed by repeat MRI examinations serially using each contrast agent. Employing a unidirectional kinetic model comprising the plasma and interstitial water compartments, tumor microvessel characteristics including fractional plasma volume and transendothelial permeability (K PS ) were estimated for each contrast medium. Tumor growth and the microvascular density, a histologic surrogate of angiogenesis, were also measured. Control tumors significantly increased (P PS ) based on MRI assays using both macromolecular contrast media. In contrast, tumor growth was significantly reduced (P PS values declined slightly. Estimated values for the fractional plasma volume did not differ significantly between treatment groups or contrast agents. Microvascular density counts correlated fairly with the tumor growth rate (r=0.64) and were statistically significant higher (P PS ), using either of two macromolecular contrast media, were able to detect effects of treatment with a VEGF receptor tyrosine kinase inhibitor on tumor vascular permeability. In a clinical setting such quantitative MRI measurements could be used to monitor tumor anti-angiogenesis therapy. (orig.)

  1. A survey of contrast media used in coronary angiograph

    International Nuclear Information System (INIS)

    Weikl, A.; Hubmann, M.

    1982-01-01

    In recent years, various contrast media have been developed for use in coronary angiography. These contrast media may be divided into ionic contrast media of high osmolality, those of low osmolality, and nonionic contrast materials. We conducted our own clinical studies with 40 patients. In random succession a standard contrast medium (ionic, of high osmolality) and a new-generation contrast medium (either nonionic or ionic with low osmolality) were injected into the right and left coronary arteries. After each injection we measured the systolic and diastolic blood pressure using a liquid-filled coronary catheter. In addition, the change in the length of the cardiac cycle was registered in terms of the R-R interval (in ms) and at the same time, leads I, II, and III of the ECG were recorded. We studied the influence of the various contrast media on the activity of ATPase in in vitro experiments, using Lasser and Lang's. When ionic contrast media of low osmolality and nonionic contrast media were utilized the heart rate showed no change. Disturbances of rhythm such as ventricular tachycardia or fibrillation were not observed. All of the contrast media used produced the same ECG changes. These changes can be ascribed to the inhibition of ATPase. The arterial blood pressure was lowered significantly only by ionic contrast media of high osmolality only. (orig.)

  2. Aspiration of Barium Contrast

    Directory of Open Access Journals (Sweden)

    Cristina Fuentes Santos

    2014-01-01

    Full Text Available The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical file was reviewed, images were found of a barium swallow study that the patient had undergone months earlier, and we were able to observe the exact moment of the aspiration of the contrast material. The patient had been asymptomatic since the test.

  3. Detection and cellular localisation of the synthetic soluble macromolecular drug carrier pHPMA

    Czech Academy of Sciences Publication Activity Database

    Kissel, M.; Peschke, P.; Šubr, Vladimír; Ulbrich, Karel; Strunz, A. M.; Kühnlein, R.; Debus, J.; Friedrich, E.

    2002-01-01

    Roč. 29, č. 8 (2002), s. 1055-1062 ISSN 1619-7070 R&D Projects: GA ČR GV307/96/K226 Institutional research plan: CEZ:AV0Z4050913 Keywords : EPR effect * Radiolabelled macromolecules * Pharmacokinetic Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.568, year: 2002

  4. UQlust: combining profile hashing with linear-time ranking for efficient clustering and analysis of big macromolecular data.

    Science.gov (United States)

    Adamczak, Rafal; Meller, Jarek

    2016-12-28

    Advances in computing have enabled current protein and RNA structure prediction and molecular simulation methods to dramatically increase their sampling of conformational spaces. The quickly growing number of experimentally resolved structures, and databases such as the Protein Data Bank, also implies large scale structural similarity analyses to retrieve and classify macromolecular data. Consequently, the computational cost of structure comparison and clustering for large sets of macromolecular structures has become a bottleneck that necessitates further algorithmic improvements and development of efficient software solutions. uQlust is a versatile and easy-to-use tool for ultrafast ranking and clustering of macromolecular structures. uQlust makes use of structural profiles of proteins and nucleic acids, while combining a linear-time algorithm for implicit comparison of all pairs of models with profile hashing to enable efficient clustering of large data sets with a low memory footprint. In addition to ranking and clustering of large sets of models of the same protein or RNA molecule, uQlust can also be used in conjunction with fragment-based profiles in order to cluster structures of arbitrary length. For example, hierarchical clustering of the entire PDB using profile hashing can be performed on a typical laptop, thus opening an avenue for structural explorations previously limited to dedicated resources. The uQlust package is freely available under the GNU General Public License at https://github.com/uQlust . uQlust represents a drastic reduction in the computational complexity and memory requirements with respect to existing clustering and model quality assessment methods for macromolecular structure analysis, while yielding results on par with traditional approaches for both proteins and RNAs.

  5. Late adverse reactions to intravascular iodine based contrast media

    DEFF Research Database (Denmark)

    Bellin, Marie-France; Stacul, Fulvio; Webb, Judith A W

    2011-01-01

    DEFINITION: Late adverse reactions (LAR) to contrast media (CM) are defined as reactions occurring 1 h to 1 week after exposure. NEED FOR REVIEW: In view of more prospective studies of LAR and new data about their pathophysiology, the Contrast Medium Safety Committee (CMSC) of the European Society...... or delayed reading intradermal). The main risk factors for LAR are a previous reaction to contrast medium, a history of allergy, and interleukin-2 treatment. Most skin reactions are mild or moderate and self-limiting. MANAGEMENT: Management is symptomatic and similar to the management of other drug......-induced skin reactions. To reduce the risk of repeat reactions avoidance of the relevant CM and any cross-reacting agents identified by skin testing is recommended....

  6. Predictive Mechanical Characterization of Macro-Molecular Material Chemistry Structures of Cement Paste at Nano Scale - Two-phase Macro-Molecular Structures of Calcium Silicate Hydrate, Tri-Calcium Silicate, Di-Calcium Silicate and Calcium Hydroxide

    Science.gov (United States)

    Padilla Espinosa, Ingrid Marcela

    Concrete is a hierarchical composite material with a random structure over a wide range of length scales. At submicron length scale the main component of concrete is cement paste, formed by the reaction of Portland cement clinkers and water. Cement paste acts as a binding matrix for the other components and is responsible for the strength of concrete. Cement paste microstructure contains voids, hydrated and unhydrated cement phases. The main crystalline phases of unhydrated cement are tri-calcium silicate (C3S) and di-calcium silicate (C2S), and of hydrated cement are calcium silicate hydrate (CSH) and calcium hydroxide (CH). Although efforts have been made to comprehend the chemical and physical nature of cement paste, studies at molecular level have primarily been focused on individual components. Present research focuses on the development of a method to model, at molecular level, and analysis of the two-phase combination of hydrated and unhydrated phases of cement paste as macromolecular systems. Computational molecular modeling could help in understanding the influence of the phase interactions on the material properties, and mechanical performance of cement paste. Present work also strives to create a framework for molecular level models suitable for potential better comparisons with low length scale experimental methods, in which the sizes of the samples involve the mixture of different hydrated and unhydrated crystalline phases of cement paste. Two approaches based on two-phase cement paste macromolecular structures, one involving admixed molecular phases, and the second involving cluster of two molecular phases are investigated. The mechanical properties of two-phase macromolecular systems of cement paste consisting of key hydrated phase CSH and unhydrated phases C3S or C2S, as well as CSH with the second hydrated phase CH were calculated. It was found that these cement paste two-phase macromolecular systems predicted an isotropic material behavior. Also

  7. Contrast media in urography, angiography and computerized tomography

    International Nuclear Information System (INIS)

    Taenzer, V.; Zeitler, E.

    1983-01-01

    The fact that new contrast media have been introduced in Germany or are currently undergoing clinical trials prompted the authors to assemble available experiences in a special edition of ''Roentgen-Fortschritte''. Particular prominence is given in the publication to preclinical and clinical experiences with another new non-ionic contrast medium, Iopromide. Experimental and clinical studies both indicate changes in certain clinically pertinent properties of the new contrast media. (orig./MG) [de

  8. The use of iodinated and gadolinium contrast media during pregnancy and lactation

    Energy Technology Data Exchange (ETDEWEB)

    Webb, Judith A.W. [St. Bartholomew' s Hospital, Department of Diagnostic Imaging, London (United Kingdom); Thomsen, Henrik S. [Copenhagen University Hospital at Herlev, Department of Diagnostic Radiology 54E2, Herlev (Denmark); Morcos, Sameh K. [Northern General Hospital, Department of Diagnostic Imaging, Sheffield (United Kingdom)

    2005-06-01

    The use of iodinated or gadolinium-based contrast media in pregnant or lactating women often causes concerns in the radiology department because of the principle of not exposing a fetus or neonate to any drugs. Because of the uncertainty about the use of contrast media during pregnancy and lactation, the Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines. An extensive literature search was carried out and summarized in a report. Based on the limited information available, simple guidelines have been drawn up. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. Mutagenic and teratogenic effects have not been described after administration of gadolinium or iodinated contrast media. Free iodide in radiographic contrast medium given to the mother has the potential to depress fetal/neonatal thyroid function. Neonatal thyroid function should be checked during the 1st week if iodinated contrast media have been given during pregnancy. No effect on the fetus has been seen after gadolinium contrast media. Only tiny amounts of iodinated or gadolinium-based contrast medium given to a lactating mother reach the milk, and only a minute proportion entering the baby's gut is absorbed. The very small potential risk associated with absorption of contrast medium may be considered insufficient to warrant stopping breast-feeding for 24 h following either iodinated or gadolinium contrast agents. (orig.)

  9. The use of iodinated and gadolinium contrast media during pregnancy and lactation

    International Nuclear Information System (INIS)

    Webb, Judith A.W.; Thomsen, Henrik S.; Morcos, Sameh K.

    2005-01-01

    The use of iodinated or gadolinium-based contrast media in pregnant or lactating women often causes concerns in the radiology department because of the principle of not exposing a fetus or neonate to any drugs. Because of the uncertainty about the use of contrast media during pregnancy and lactation, the Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines. An extensive literature search was carried out and summarized in a report. Based on the limited information available, simple guidelines have been drawn up. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. Mutagenic and teratogenic effects have not been described after administration of gadolinium or iodinated contrast media. Free iodide in radiographic contrast medium given to the mother has the potential to depress fetal/neonatal thyroid function. Neonatal thyroid function should be checked during the 1st week if iodinated contrast media have been given during pregnancy. No effect on the fetus has been seen after gadolinium contrast media. Only tiny amounts of iodinated or gadolinium-based contrast medium given to a lactating mother reach the milk, and only a minute proportion entering the baby's gut is absorbed. The very small potential risk associated with absorption of contrast medium may be considered insufficient to warrant stopping breast-feeding for 24 h following either iodinated or gadolinium contrast agents. (orig.)

  10. Coevolutionary constraints in the sequence-space of macromolecular complexes reflect their self-assembly pathways.

    Science.gov (United States)

    Mallik, Saurav; Kundu, Sudip

    2017-07-01

    Is the order in which biomolecular subunits self-assemble into functional macromolecular complexes imprinted in their sequence-space? Here, we demonstrate that the temporal order of macromolecular complex self-assembly can be efficiently captured using the landscape of residue-level coevolutionary constraints. This predictive power of coevolutionary constraints is irrespective of the structural, functional, and phylogenetic classification of the complex and of the stoichiometry and quaternary arrangement of the constituent monomers. Combining this result with a number of structural attributes estimated from the crystal structure data, we find indications that stronger coevolutionary constraints at interfaces formed early in the assembly hierarchy probably promotes coordinated fixation of mutations that leads to high-affinity binding with higher surface area, increased surface complementarity and elevated number of molecular contacts, compared to those that form late in the assembly. Proteins 2017; 85:1183-1189. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  11. Intravenous contrast media application using cone-beam computed tomography in a rabbit model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Sung; Kim, Bok Yeol; Choi, Hwa Young [Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of); and others

    2015-03-15

    This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.

  12. Intravenous contrast media application using cone-beam computed tomography in a rabbit model

    International Nuclear Information System (INIS)

    Kim, Min Sung; Kim, Bok Yeol; Choi, Hwa Young

    2015-01-01

    This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.

  13. Contrast-enhanced ultrasound imaging of active bleeding associated with hepatic and splenic trauma.

    Science.gov (United States)

    Lv, F; Tang, J; Luo, Y; Li, Z; Meng, X; Zhu, Z; Li, T

    2011-10-01

    The aim of this study was to evaluate contrast-enhanced ultrasound (CEUS) imaging of active bleeding from hepatic and splenic trauma. Three hundred and ninety-two patients with liver or/and spleen trauma (179 liver and 217 spleen injuries), who underwent CEUS examinations following contrast-enhanced computed tomography (CT), were enrolled in this retrospective study over a period of >4 years. CEUS detected contrast medium extravasation or pooling in 16% (63/396) of liver or spleen lesions in 61 patients, which was confirmed by contrast-enhanced CT. Special attention was paid to observing the presence, location, and characteristics of the extravasated or pooled contrast medium. The CEUS detection rate for active bleeding was not different from that of contrast-enhanced CT (p=0.333). Information from surgery, minimally invasive treatment and conservative treatment was used as reference standard, and the sensitivities of the two techniques were not different (p=0.122). Of 63 lesions in 61 patients, CEUS showed that 74.6% (47/63) (21 liver lesions and 26 spleen lesions) presented contrast medium extravasation or pooling, both in the organ and out the capsule, in 14.3% (9/63) and only outside the capsule in 11.1% (7/63). CEUS imaging of active bleeding from hepatic and splenic trauma presented various characteristics, and the sizes and shapes of the active bleeding due to contrast medium extravasation or pooling were variable. CEUS can show the active bleeding associated with hepatic and splenic trauma with various imaging characteristics, thus making it possible to diagnose active bleeding using CEUS.

  14. In Vivo Differentiation of Complementary Contrast Media at Dual-Energy CT

    Science.gov (United States)

    Mongan, John; Rathnayake, Samira; Fu, Yanjun; Wang, Runtang; Jones, Ella F.; Gao, Dong-Wei

    2012-01-01

    Purpose: To evaluate the feasibility of using a commercially available clinical dual-energy computed tomographic (CT) scanner to differentiate the in vivo enhancement due to two simultaneously administered contrast media with complementary x-ray attenuation ratios. Materials and Methods: Approval from the institutional animal care and use committee was obtained, and National Institutes of Health guidelines for the care and use of laboratory animals were observed. Dual-energy CT was performed in a set of iodine and tungsten solution phantoms and in a rabbit in which iodinated intravenous and bismuth subsalicylate oral contrast media were administered. In addition, a second rabbit was studied after intravenous administration of iodinated and tungsten cluster contrast media. Images were processed to produce virtual monochromatic images that simulated the appearance of conventional single-energy scans, as well as material decomposition images that separate the attenuation due to each contrast medium. Results: Clear separation of each of the contrast media pairs was seen in the phantom and in both in vivo animal models. Separation of bowel lumen from vascular contrast medium allowed visualization of bowel wall enhancement that was obscured by intraluminal bowel contrast medium on conventional CT scans. Separation of two vascular contrast media in different vascular phases enabled acquisition of a perfectly coregistered CT angiogram and venous phase–enhanced CT scan simultaneously in a single examination. Conclusion: Commercially available clinical dual-energy CT scanners can help differentiate the enhancement of selected pairs of complementary contrast media in vivo. © RSNA, 2012 PMID:22778447

  15. Comparison of in vitro histamine release by ionic and nonionic radiographyic contrast media

    International Nuclear Information System (INIS)

    Faraj, B.A.; Martin, L.G.

    1989-01-01

    This paper discusses a study whose results showed that in 53 hospitalized patients undergoing cardiovascular catheterization, incubation of their blood samples with varying concentrations of an ionic contrast medium (Angiovist-370, 60--631 mM) induced a significant (P < .005) amount of histamine release from whole blood (3.5%--10%), as compared with the histamine release following incubation with a nonionic contrast medium. Data suggest that the use of nonionic contrast media may induce minimal histamine release and thereby involve less patient risk from the histamine-mediated allergic and hemodynamic side effects associated with radiographic contrast media procedures

  16. Interplay between the bacterial nucleoid protein H-NS and macromolecular crowding in compacting DNA

    NARCIS (Netherlands)

    Wintraecken, C.H.J.M.

    2012-01-01

    In this dissertation we discuss H-NS and its connection to nucleoid compaction and organization. Nucleoid formation involves a dramatic reduction in coil volume of the genomic DNA. Four factors are thought to influence coil volume: supercoiling, DNA charge neutralization, macromolecular

  17. Bringing macromolecular machinery to life using 3D animation.

    Science.gov (United States)

    Iwasa, Janet H

    2015-04-01

    Over the past decade, there has been a rapid rise in the use of three-dimensional (3D) animation to depict molecular and cellular processes. Much of the growth in molecular animation has been in the educational arena, but increasingly, 3D animation software is finding its way into research laboratories. In this review, I will discuss a number of ways in which 3d animation software can play a valuable role in visualizing and communicating macromolecular structures and dynamics. I will also consider the challenges of using animation tools within the research sphere. Copyright © 2015. Published by Elsevier Ltd.

  18. Synthesis and evaluation of nanoglobule-cystamine-(Gd-DO3A, a biodegradable nanosized magnetic resonance contrast agent for dynamic contrast-enhanced magnetic resonance urography

    Directory of Open Access Journals (Sweden)

    Rongzuo Xu

    2010-09-01

    Full Text Available Rongzuo Xu1, Todd Lyle Kaneshiro1, Eun-Kee Jeong2, Dennis L Parker2, Zheng-Rong Lu31Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, Salt Lake City, UT, USA; 2Department of Radiology, University of Utah, Salt Lake City, UT, USA; 3Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USAAbstract: Dynamic contrast-enhanced magnetic resonance imaging has been recently shown to be effective for diagnostic urography. High-resolution urographic images can be acquired with T1 contrast agents for the kidney and urinary tract with minimal noise in the abdomen. Currently, clinical contrast agents are low molecular weight agents and can rapidly extravasate from blood circulation, leading to slow contrast agent elimination through kidney and consequently providing limited contrast enhancement in urinary tract. In this study, a new biodegradable macromolecular contrast agent, nanoglobule-G4-cystamine-(Gd-DO3A, was prepared by conjugating Gd-DO3A chelates on the surface of a generation 4 nanoglobule, poly-l-lysine octa(3-aminopropylsilsesquioxane dendrimer, via a disulfide spacer, where the carrier had a precisely defined nanosize that is far smaller than the renal filtration threshold. The in vivo contrast enhancement and dynamic imaging of the urinary tract of the agent was evaluated in nude mice using a low molecular weight agent Gd(DTPA-BMA as a control. The agent eliminated rapidly from blood circulation and accumulated more abundantly in urinary tract than Gd(DTPA-BMA. The fast elimination kinetics is ideal for functional evaluation of the kidneys. The morphology of the kidneys and urinary tract was better visualized by the biodegradable nanoglobular contrast agent than Gd(DTPA-BMA. The agent also resulted in low liver contrast enhancement, indicating low nonspecific tissue deposition. These features render the G4 nanoglobule-cystamine-(Gd-DO3A conjugate a promising contrast agent for magnetic

  19. Depiction of normal gastrointestinal anatomy with MDCT: comparison of low- and high-attenuation oral contrast media.

    Science.gov (United States)

    Erturk, Sukru Mehmet; Mortelé, Koenraad J; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R

    2008-04-01

    To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Duodenal, jejunal and ileal distention (pcontrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (pcontrast medium, for reader 2. Interobserver agreement was fair to good for both distention (kappa-range: 0.41-0.74) and wall visualization (kappa-range: 0.48-0.71). MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium.

  20. Macromolecular composition of terrestrial and marine organic matter in sediments across the East Siberian Arctic Shelf

    Directory of Open Access Journals (Sweden)

    R. B. Sparkes

    2016-10-01

    Full Text Available Mobilisation of terrestrial organic carbon (terrOC from permafrost environments in eastern Siberia has the potential to deliver significant amounts of carbon to the Arctic Ocean, via both fluvial and coastal erosion. Eroded terrOC can be degraded during offshore transport or deposited across the wide East Siberian Arctic Shelf (ESAS. Most studies of terrOC on the ESAS have concentrated on solvent-extractable organic matter, but this represents only a small proportion of the total terrOC load. In this study we have used pyrolysis–gas chromatography–mass spectrometry (py-GCMS to study all major groups of macromolecular components of the terrOC; this is the first time that this technique has been applied to the ESAS. This has shown that there is a strong offshore trend from terrestrial phenols, aromatics and cyclopentenones to marine pyridines. There is good agreement between proportion phenols measured using py-GCMS and independent quantification of lignin phenol concentrations (r2 = 0.67, p < 0.01, n = 24. Furfurals, thought to represent carbohydrates, show no offshore trend and are likely found in both marine and terrestrial organic matter. We have also collected new radiocarbon data for bulk OC (14COC which, when coupled with previous measurements, allows us to produce the most comprehensive 14COC map of the ESAS to date. Combining the 14COC and py-GCMS data suggests that the aromatics group of compounds is likely sourced from old, aged terrOC, in contrast to the phenols group, which is likely sourced from modern woody material. We propose that an index of the relative proportions of phenols and pyridines can be used as a novel terrestrial vs. marine proxy measurement for macromolecular organic matter. Principal component analysis found that various terrestrial vs. marine proxies show different patterns across the ESAS, and it shows that multiple river–ocean transects of surface sediments transition from river-dominated to

  1. In vivo magnetic resonance imaging of atherosclerotic lesions with a newly developed Evans blue-DTPA-gadolinium contrast medium in apolipoprotein-E-deficient mice.

    Science.gov (United States)

    Yasuda, Satoshi; Ikuta, Kenjiro; Uwatoku, Toyokazu; Oi, Keiji; Abe, Kohtaro; Hyodo, Fuminori; Yoshimitsu, Kengo; Sugimura, Kohtaro; Utsumi, Hideo; Katayama, Yoshiki; Shimokawa, Hiroaki

    2008-01-01

    Magnetic resonance imaging (MRI) contrast agents that specifically detect atherosclerotic plaque may be useful for the noninvasive detection of the plaque. We have recently developed a new contrast agent, Evans blue-DTPA-gadolinium (EB-DTPA-Gd), which selectively accumulates vascular lesions with endothelial removal. In this study, we examined whether EB-DTPA-Gd is also useful for in vivo imaging of atherosclerotic plaques. We used male apolipoprotein-E-deficient (ApoE-/-) mice of different ages (3, 6 and 12 months old) and age-matched male wild-type mice. After a single intravenous administration of EB-DTPA-Gd (160 microM/kg body weight), MRI T(1) signal was obtained in vivo. Increased signal intensity in the aortic wall was noted within 10-20 min after intravenous injection of EB-DTPA-Gd and was maintained for 30 min. The MRI enhancement in the aorta of ApoE-/- mice was increased in accordance with age, whereas no such enhancement was noted in wild-type mice. Histological examination demonstrated that there was a topological correlation between the site of MRI enhancement and that of atherosclerotic plaque. These results indicate that EB-DTPA-Gd is a useful MRI contrast medium for the in vivo detection of atherosclerotic plaques. Copyright (c) 2007 S. Karger AG, Basel.

  2. Clustering procedures for the optimal selection of data sets from multiple crystals in macromolecular crystallography

    International Nuclear Information System (INIS)

    Foadi, James; Aller, Pierre; Alguel, Yilmaz; Cameron, Alex; Axford, Danny; Owen, Robin L.; Armour, Wes; Waterman, David G.; Iwata, So; Evans, Gwyndaf

    2013-01-01

    A systematic approach to the scaling and merging of data from multiple crystals in macromolecular crystallography is introduced and explained. The availability of intense microbeam macromolecular crystallography beamlines at third-generation synchrotron sources has enabled data collection and structure solution from microcrystals of <10 µm in size. The increased likelihood of severe radiation damage where microcrystals or particularly sensitive crystals are used forces crystallographers to acquire large numbers of data sets from many crystals of the same protein structure. The associated analysis and merging of multi-crystal data is currently a manual and time-consuming step. Here, a computer program, BLEND, that has been written to assist with and automate many of the steps in this process is described. It is demonstrated how BLEND has successfully been used in the solution of a novel membrane protein

  3. Clustering procedures for the optimal selection of data sets from multiple crystals in macromolecular crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Foadi, James [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); Imperial College, London SW7 2AZ (United Kingdom); Aller, Pierre [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); Alguel, Yilmaz; Cameron, Alex [Imperial College, London SW7 2AZ (United Kingdom); Axford, Danny; Owen, Robin L. [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); Armour, Wes [Oxford e-Research Centre (OeRC), Keble Road, Oxford OX1 3QG (United Kingdom); Waterman, David G. [Research Complex at Harwell (RCaH), Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0FA (United Kingdom); Iwata, So [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); Imperial College, London SW7 2AZ (United Kingdom); Evans, Gwyndaf, E-mail: gwyndaf.evans@diamond.ac.uk [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom)

    2013-08-01

    A systematic approach to the scaling and merging of data from multiple crystals in macromolecular crystallography is introduced and explained. The availability of intense microbeam macromolecular crystallography beamlines at third-generation synchrotron sources has enabled data collection and structure solution from microcrystals of <10 µm in size. The increased likelihood of severe radiation damage where microcrystals or particularly sensitive crystals are used forces crystallographers to acquire large numbers of data sets from many crystals of the same protein structure. The associated analysis and merging of multi-crystal data is currently a manual and time-consuming step. Here, a computer program, BLEND, that has been written to assist with and automate many of the steps in this process is described. It is demonstrated how BLEND has successfully been used in the solution of a novel membrane protein.

  4. 2D and 3D parameter images for analysis of contrast medium enhancement based on dynamic CT and MR

    International Nuclear Information System (INIS)

    Beier, J.; Stroszczynski, C.; Oellinger, H.; Felix, R.; Buege, T.; Fleck, E.

    1998-01-01

    Aim: For dynamic contrast medium (CM) studies, parameter images exploit specific features of the time/intensity curve (TIC) of each pixel and represent these values in a new image. Existing concepts of two-dimensional CM analysis are extended for three-dimensional applications using adequate computer graphic visualization. Results: In first-pass analyses, TMIP and TG allowed the simultaneous or separted presentation of different temporal phases of the CM bolus. Correlation images emphasized regions with similarities to given TIC patterns. Three-dimensional computer graphic techniques enabled (1) anatomical/function mapping of original image and CM accumulation and (2) fused display of both spatial CM enhancement and color-encoded time of TIC peak in one common image. Conclusions: The quantifiction of presence, magnitude, and time-of-peak of CM accumulation in local image regions supports the assessment of vascularization and of ischemic or necrotic areas. (orig./AJ) [de

  5. Synthesis of novel complexing macromolecular surfactants and study of their interactions with cobalt for the development of a decontamination process of textiles in dense CO2 medium

    International Nuclear Information System (INIS)

    Chirat, M.

    2012-01-01

    This study is about textile decontamination in dense CO 2 (liquid CO 2 or supercritical CO 2 ). The study is carried out in the framework of decontamination of textile used in the nuclear industry. The dense CO 2 offers an alternative to aqueous medium used in the current process which generates a huge quantity of contaminated aqueous effluent requiring a post-treatment. Cobalt is the targeted contamination and can be found as ionic species or particles. The cobalt extraction in dense CO 2 is achieved with an additive: a complexing CO 2 -philic/CO 2 -phobic macromolecular surfactant. Several types of additives were synthesized by controlled free radical polymerization: gradient copolymers made with CO 2 -philic groups (silicone-based or fluorinated moieties) and CO 2 -phobic complexing groups (aceto acetoxy, di-ethylphosphonate or phosphonic acid moieties). The copolymer behavior in dense CO 2 was determined by phase diagram measurements (cloud point method) and their self-assembly in dense CO 2 was investigated by small angle neutron scattering. The fluorinated copolymers were found advantageous in terms of solubility. Nevertheless, the silicone-based copolymers showed solubilities which are compatible with the process, therefore they are a good alternative to avoid fluorinated compounds which are unwanted in the conditioning of nuclear wastes. The study of cobalt complexation by the copolymers (UV-vis spectroscopy and inductively coupled plasma-mass spectroscopy) established relations between the type of complexing group and the affinity with the cobalt. The solubility of copolymer-cobalt complexes in dense CO 2 is similar to those of copolymers. Moreover, the self-assembly study of the complex revealed a low aggregation. Finally, the synthesized copolymers were used in particle or ionic decontamination processes. In the case of ionic decontamination process, a rate of 70% of decontamination was reached with the use of gradient copolymer poly(1

  6. Recent Major Improvements to the ALS Sector 5 Macromolecular Crystallography Beamlines

    International Nuclear Information System (INIS)

    Morton, Simon A.; Glossinger, James; Smith-Baumann, Alexis; McKean, John P.; Trame, Christine; Dickert, Jeff; Rozales, Anthony; Dauz, Azer; Taylor, John; Zwart, Petrus; Duarte, Robert; Padmore, Howard; McDermott, Gerry; Adams, Paul

    2007-01-01

    Although the Advanced Light Source (ALS) was initially conceived primarily as a low energy (1.9GeV) 3rd generation source of VUV and soft x-ray radiation it was realized very early in the development of the facility that a multipole wiggler source coupled with high quality, (brightness preserving), optics would result in a beamline whose performance across the optimal energy range (5-15keV) for macromolecular crystallography (MX) would be comparable to, or even exceed, that of many existing crystallography beamlines at higher energy facilities. Hence, starting in 1996, a suite of three beamlines, branching off a single wiggler source, was constructed, which together formed the ALS Macromolecular Crystallography Facility. From the outset this facility was designed to cater equally to the needs of both academic and industrial users with a heavy emphasis placed on the development and introduction of high throughput crystallographic tools, techniques, and facilities--such as large area CCD detectors, robotic sample handling and automounting facilities, a service crystallography program, and a tightly integrated, centralized, and highly automated beamline control environment for users. This facility was immediately successful, with the primary Multiwavelength Anomalous Diffraction beamline (5.0.2) in particular rapidly becoming one of the foremost crystallographic facilities in the US--responsible for structures such as the 70S ribosome. This success in-turn triggered enormous growth of the ALS macromolecular crystallography community and spurred the development of five additional ALS MX beamlines all utilizing the newly developed superconducting bending magnets ('superbends') as sources. However in the years since the original Sector 5.0 beamlines were built the performance demands of macromolecular crystallography users have become ever more exacting; with growing emphasis placed on studying larger complexes, more difficult structures, weakly diffracting or smaller

  7. Macromolecularly crowded in vitro microenvironments accelerate the production of extracellular matrix-rich supramolecular assemblies.

    Science.gov (United States)

    Kumar, Pramod; Satyam, Abhigyan; Fan, Xingliang; Collin, Estelle; Rochev, Yury; Rodriguez, Brian J; Gorelov, Alexander; Dillon, Simon; Joshi, Lokesh; Raghunath, Michael; Pandit, Abhay; Zeugolis, Dimitrios I

    2015-03-04

    Therapeutic strategies based on the principles of tissue engineering by self-assembly put forward the notion that functional regeneration can be achieved by utilising the inherent capacity of cells to create highly sophisticated supramolecular assemblies. However, in dilute ex vivo microenvironments, prolonged culture time is required to develop an extracellular matrix-rich implantable device. Herein, we assessed the influence of macromolecular crowding, a biophysical phenomenon that regulates intra- and extra-cellular activities in multicellular organisms, in human corneal fibroblast culture. In the presence of macromolecules, abundant extracellular matrix deposition was evidenced as fast as 48 h in culture, even at low serum concentration. Temperature responsive copolymers allowed the detachment of dense and cohesive supramolecularly assembled living substitutes within 6 days in culture. Morphological, histological, gene and protein analysis assays demonstrated maintenance of tissue-specific function. Macromolecular crowding opens new avenues for a more rational design in engineering of clinically relevant tissue modules in vitro.

  8. Long-wavelength macromolecular crystallography - First successful native SAD experiment close to the sulfur edge

    Science.gov (United States)

    Aurelius, O.; Duman, R.; El Omari, K.; Mykhaylyk, V.; Wagner, A.

    2017-11-01

    Phasing of novel macromolecular crystal structures has been challenging since the start of structural biology. Making use of anomalous diffraction of natively present elements, such as sulfur and phosphorus, for phasing has been possible for some systems, but hindered by the necessity to access longer X-ray wavelengths in order to make most use of the anomalous scattering contributions of these elements. Presented here are the results from a first successful experimental phasing study of a macromolecular crystal structure at a wavelength close to the sulfur K edge. This has been made possible by the in-vacuum setup and the long-wavelength optimised experimental setup at the I23 beamline at Diamond Light Source. In these early commissioning experiments only standard data collection and processing procedures have been applied, in particular no dedicated absorption correction has been used. Nevertheless the success of the experiment demonstrates that the capability to extract phase information can be even further improved once data collection protocols and data processing have been optimised.

  9. The In-Situ One-Step Synthesis of a PDC Macromolecular Pro-Drug and the Fabrication of a Novel Core-Shell Micell.

    Science.gov (United States)

    Yu, Cui-Yun; Yang, Sa; Li, Zhi-Ping; Huang, Can; Ning, Qian; Huang, Wen; Yang, Wen-Tong; He, Dongxiu; Sun, Lichun

    2016-01-01

    The development of slow release nano-sized carriers for efficient antineoplastic drug delivery with a biocompatible and biodegradable pectin-based macromolecular pro-drug for tumor therapy has been reported in this study. Pectin-doxorubicin conjugates (PDC), a macromolecular pro-drug, were prepared via an amide condensation reaction, and a novel amphiphilic core-shell micell based on a PDC macromolecular pro-drug (PDC-M) was self-assembled in situ, with pectin as the hydrophilic shell and doxorubicin (DOX) as the hydrophobic core. Then the chemical structure of the PDC macromolecular pro-drug was identified by both Fourier transform infrared spectroscopy (FTIR) and nuclear magnetic resonance spectroscopy ((1)H-NMR), and proved that doxorubicin combined well with the pectin and formed macromolecular pro-drug. The PDC-M were observed to have an unregularly spherical shape and were uniform in size by scanning electron microscopy (SEM). The average particle size of PDC-M, further measured by a Zetasizer nanoparticle analyzer (Nano ZS, Malvern Instruments), was about 140 nm. The encapsulation efficiency and drug loading were 57.82% ± 3.7% (n = 3) and 23.852% ±2.3% (n = 3), respectively. The in vitro drug release behaviors of the resulting PDC-M were studied in a simulated tumor environment (pH 5.0), blood (pH 7.4) and a lysosome media (pH 6.8), and showed a prolonged slow release profile. Assays for antiproliferative effects and flow cytometry of the resulting PDC-M in HepG2 cell lines demonstrated greater properties of delayed and slow release as compared to free DOX. A cell viability study against endothelial cells further revealed that the resulting PDC-M possesses excellent cell compatibilities and low cytotoxicities in comparison with that of the free DOX. Hemolysis activity was investigated in rabbits, and the results also demonstrated that the PDC-M has greater compatibility in comparison with free DOX. This shows that the resulting PDC-M can ameliorate the

  10. Late adverse reactions to intravascular iodine based contrast media

    DEFF Research Database (Denmark)

    Bellin, Marie-France; Stacul, Fulvio; Webb, Judith A W

    2011-01-01

    DEFINITION: Late adverse reactions (LAR) to contrast media (CM) are defined as reactions occurring 1 h to 1 week after exposure. NEED FOR REVIEW: In view of more prospective studies of LAR and new data about their pathophysiology, the Contrast Medium Safety Committee (CMSC) of the European Societ...

  11. Depiction of normal gastrointestinal anatomy with MDCT: Comparison of low- and high-attenuation oral contrast media

    International Nuclear Information System (INIS)

    Erturk, Sukru Mehmet; Mortele, Koenraad J.; Oliva, Maria-Raquel; Ichikawa, Tomoaki; Silverman, Stuart G.; Cantisani, Vito; Pagliara, Elisa; Ros, Pablo R.

    2008-01-01

    Purpose: To compare low- and high-attenuation oral contrast media for depiction of normal gastrointestinal anatomy with multidetector-row computed tomography (MDCT). Materials and methods: A prospective, randomized study of 90 consecutive patients without known or suspected gastrointestinal disease was conducted after the approval of our Institutional Review Board. All patients underwent IV contrast-enhanced abdominal and pelvic CT scans after oral administration of 900 ml of either low- or high-attenuation barium sulphate suspension. Using a five-point scale, two radiologists independently graded distention and wall visualization of stomach, duodenum, jejunum, and ileum. The degree of distention and wall visualization was compared using Mann-Whitney U-test. Results: Duodenal, jejunal and ileal distention (p < 0.05, <0.001, <0.001, respectively) and wall visualization (p < 0.05, <0.01, <0.05, respectively) scores with low-attenuation contrast medium were significantly higher than those with high-attenuation barium sulphate preparation, for reader 1. Duodenal and jejunal wall visualization scores with low-attenuation contrast medium (p < 0.05, <0.01, respectively) were significantly higher than those with high-attenuation contrast medium, for reader 2. Interobserver agreement was fair to good for both distention (κ-range: 0.41-0.74) and wall visualization (κ-range: 0.48-0.71). Conclusion: MDCT with low-attenuation contrast medium provides distention and wall visualization of the GI tract that is equal or better than high-attenuation contrast medium

  12. MX1: a bending-magnet crystallography beamline serving both chemical and macromolecular crystallography communities at the Australian Synchrotron

    International Nuclear Information System (INIS)

    Cowieson, Nathan Philip; Aragao, David; Clift, Mark; Ericsson, Daniel J.; Gee, Christine; Harrop, Stephen J.; Mudie, Nathan; Panjikar, Santosh; Price, Jason R.; Riboldi-Tunnicliffe, Alan; Williamson, Rachel; Caradoc-Davies, Tom

    2015-01-01

    The macromolecular crystallography beamline MX1 at the Australian Synchrotron is described. MX1 is a bending-magnet crystallography beamline at the 3 GeV Australian Synchrotron. The beamline delivers hard X-rays in the energy range from 8 to 18 keV to a focal spot at the sample position of 120 µm FWHM. The beamline endstation and ancillary equipment facilitate local and remote access for both chemical and biological macromolecular crystallography. Here, the design of the beamline and endstation are discussed. The beamline has enjoyed a full user program for the last seven years and scientific highlights from the user program are also presented

  13. Synthesis of branched polymers under continuous-flow microprocess: an improvement of the control of macromolecular architectures.

    Science.gov (United States)

    Bally, Florence; Serra, Christophe A; Brochon, Cyril; Hadziioannou, Georges

    2011-11-15

    Polymerization reactions can benefit from continuous-flow microprocess in terms of kinetics control, reactants mixing or simply efficiency when high-throughput screening experiments are carried out. In this work, we perform for the first time the synthesis of branched macromolecular architecture through a controlled/'living' polymerization technique, in tubular microreactor. Just by tuning process parameters, such as flow rates of the reactants, we manage to generate a library of polymers with various macromolecular characteristics. Compared to conventional batch process, polymerization kinetics shows a faster initiation step and more interestingly an improved branching efficiency. Due to reduced diffusion pathway, a characteristic of microsystems, it is thus possible to reach branched polymers exhibiting a denser architecture, and potentially a higher functionality for later applications. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Computed tomography of kidney with diuretics. A method for avoiding artifact due to nonionic contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hiromura, Tadao; Terae, Satoshi; Takamura, Akio; Mizoe, Junetsu (Obihiro Kosei Hospital, Hokkaido (Japan)); Morita, Yutaka; Irie, Goro

    1989-07-01

    We devised a method for avoiding beam-hardening artifacts, which interfere with enhanced CT images of kidney due to nonionic contrast medium. The radiographic effect and the frequency of beam-hardening artifacts on enhanced CT of kidney were studied by prospective comparison among three groups: a group of 20 patients examined with furosemide (f-d.CT), a group of 20 patients examined without diuretics (non-d.CT) and a group of 20 patients examined after water intake (w-d.CT). In all patients of f-d.CT group, the renal parenchyma from the cortex to the papilla was almost evently enhanced, free from artifacts. The density of the renal papilla and pelvis in non-d.CT and w-d.CT groups was significantly higher than that in f-d.CT group, and artifacts were also observed in 14 (70%) of non-d.CT group and 12 (60%) of w.d.CT group, respectively. Satisfactory CT of kidney free from artifacts was obtained by f-d.CT, providing easy evaluation of renal pelvic or peripelvic lesions. In conclusion, this technique can be used in those pathologic cases of renal pelvis or peripelvic region, that are not clear on routine CT because of artifacts. (author).

  15. Structural analysis of nanoparticulate carriers for encapsulation of macromolecular drugs

    Czech Academy of Sciences Publication Activity Database

    Angelov, Borislav; Garamus, V.M.; Drechsler, M.; Angelova, A.

    2017-01-01

    Roč. 235, Jun (2017), s. 83-89 ISSN 0167-7322 R&D Projects: GA MŠk EF15_003/0000447; GA MŠk EF15_008/0000162 Grant - others:OP VVV - ELIBIO(XE) CZ.02.1.01/0.0/0.0/15_003/0000447; ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:68378271 Keywords : self-assembled nanocarriers * liquid crystalline phase transitions * cationic lipids * macromolecular drugs Subject RIV: BO - Biophysics OBOR OECD: Biophysics Impact factor: 3.648, year: 2016

  16. Protein crystal growth studies at the Center for Macromolecular Crystallography

    International Nuclear Information System (INIS)

    DeLucas, Lawrence J.; Long, Marianna M.; Moore, Karen M.; Harrington, Michael; McDonald, William T.; Smith, Craig D.; Bray, Terry; Lewis, Johanna; Crysel, William B.; Weise, Lance D.

    2000-01-01

    The Center for Macromolecular Crystallography (CMC) has been involved in fundamental studies of protein crystal growth (PCG) in microgravity and in our earth-based laboratories. A large group of co-investigators from academia and industry participated in these experiments by providing protein samples and by performing the x-ray crystallographic analysis. These studies have clearly demonstrated the usefulness of a microgravity environment for enhancing the quality and size of protein crystals. Review of the vapor diffusion (VDA) PCG results from nineteen space shuttle missions is given in this paper

  17. Alterations of serum potassium, serum magnesium and adenosine diphosphate due to various contrast media containing iodine

    International Nuclear Information System (INIS)

    Lehrberger, G.

    1979-01-01

    As an introduction of the chemical structure of contrast media is explained. Then follows a survey about the complication rates in examinations with intravascularly applicable iodine-containing contrast media. In the next part clinical symptoms and signs of general and localized contrast media incompatibility reactions, the contrast medium protein reaction and the relationship between allergic reaction and contrast medium are explained. It was tried to attribute the large amount of side-effects to one primary reaction. In this connection the three above-mentioned components were investigated. (orig./MG) [de

  18. Contrast Agent in Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Vu-Quang, Hieu

    2015-01-01

    Nanoparticles have been employed as contrast agent in magnetic resonance imaging (MRI) in order to improve sensitivity and accuracy in diagnosis. In addition, these contrast agents are potentially combined with other therapeutic compounds or near infrared bio-imaging (NIR) fluorophores to obtain...... theranostic or dual imaging purposes, respectively. There were two main types of MRI contrast agent that were synthesized during this PhD project including fluorine containing nanoparticles and magnetic nanoparticles. In regard of fluorine containing nanoparticles, there were two types contrast agent...... cancer cells for cancer diagnosis in MRI. F127-Folate coated SPION were stable in various types of suspension medium for over six months. They could specifically target folate receptor of cancer cells in vitro and in vivo thus enhancing the contrast in MRI T2/T2* weighted images. These are preliminary...

  19. Extraction of cobalt ion from textile using a complexing macromolecular surfactant in supercritical carbon dioxide

    International Nuclear Information System (INIS)

    Chirat, Mathieu; Ribaut, Tiphaine; Clerc, Sebastien; Lacroix-Desmazes, Patrick; Charton, Frederic; Fournel, Bruno

    2013-01-01

    Cobalt ion under the form of cobalt nitrate is removed from a textile lab coat using supercritical carbon dioxide extraction. The process involves a macromolecular additive of well-defined architecture, acting both as a surfactant and a complexing agent. The extraction efficiency of cobalt reaches 66% when using a poly(1,1,2,2-tetrahydroperfluoro-decyl-acrylate-co-vinyl-benzylphosphonic diacid) gradient copolymer in the presence of water at 160 bar and 40 C. The synergy of the two additives, namely the copolymer and water which are useless if used separately, is pointed out. The potential of the supercritical carbon dioxide process using complexing macromolecular surfactant lies in the ability to modulate the complexing unit as a function of the metal as well as the architecture of the surface-active agent for applications ranging for instance from nuclear decontamination to the recovery of strategic metals. (authors)

  20. E-MSD: the European Bioinformatics Institute Macromolecular Structure Database.

    Science.gov (United States)

    Boutselakis, H; Dimitropoulos, D; Fillon, J; Golovin, A; Henrick, K; Hussain, A; Ionides, J; John, M; Keller, P A; Krissinel, E; McNeil, P; Naim, A; Newman, R; Oldfield, T; Pineda, J; Rachedi, A; Copeland, J; Sitnov, A; Sobhany, S; Suarez-Uruena, A; Swaminathan, J; Tagari, M; Tate, J; Tromm, S; Velankar, S; Vranken, W

    2003-01-01

    The E-MSD macromolecular structure relational database (http://www.ebi.ac.uk/msd) is designed to be a single access point for protein and nucleic acid structures and related information. The database is derived from Protein Data Bank (PDB) entries. Relational database technologies are used in a comprehensive cleaning procedure to ensure data uniformity across the whole archive. The search database contains an extensive set of derived properties, goodness-of-fit indicators, and links to other EBI databases including InterPro, GO, and SWISS-PROT, together with links to SCOP, CATH, PFAM and PROSITE. A generic search interface is available, coupled with a fast secondary structure domain search tool.

  1. Macromolecular Engineering: New Routes Towards the Synthesis of Well-??Defined Polyethers/Polyesters Co/Terpolymers with Different Architectures

    KAUST Repository

    Alamri, Haleema

    2016-01-01

    Macromolecular engineering (as discussed in the first chapter) of homo/copolymers refers to the specific tailoring of these materials for achieving an easy and reproducible synthesis that results in precise molecular

  2. Contrast medium at the site of the anastomosis is crucial in detecting anastomotic leakage with CT imaging after colorectal surgery.

    Science.gov (United States)

    Huiberts, Astrid A M; Dijksman, Lea M; Boer, Simone A; Krul, Eveline J T; Peringa, Jan; Donkervoort, Sandra C

    2015-06-01

    The use of computed tomography (CT) to detect anastomotic leakage (AL) is becoming the standard of care. Accurate detection of AL is crucial. The aim of this study was to define CT criteria that are most predictive for AL. From January 2006 to December 2012, all consecutive patients who had undergone CT imaging because of clinical suspicion of anastomotic leakage after colorectal surgery were analysed. All CT scans were re-evaluated by two independent abdominal radiologists blinded for clinical outcome. The images were scored with a set of criteria and a conclusion whether or not AL was present was drawn. Each separate criterion was analysed for its value in predicting AL by uni- and multivariable logistic regression Of 668 patients with colorectal surgery, 108 had undergone CT imaging within 16 days postoperatively. According to our standard of reference, 34 (31%) of the patients had AL. Univariable analysis showed that "fluid near anastomosis" (radiologist 1 (rad 1), p leakage" (rad 1, p leakage was the only independent predictor for AL in multivariable analysis for both radiologists (rad 1, OR 5.43 (95% CI 1.18-25.02); rad 2, OR 8.51 (95% CI 2.21-32.83)). The only independent variable predicting AL is leakage of contrast medium. To improve the accuracy of CT imaging, optimal contrast administration near the anastomosis appears to be crucial.

  3. Contrast enhancement of the gyri in herpes simplex encephalitis

    International Nuclear Information System (INIS)

    Schumacher, K.A.; Langer, M.; Langer, R.

    1982-01-01

    A case of herpes simplex encephalitis was examined by computer tomography. Both cerebral hemispheres showed contrast enhancement of the gyri. The cause of this is considered. The increased contrast medium accumulation in the affected areas is probably due to the marked vascular proliferation which can be demonstrated anatomically, and to the rapid escape of contrast from the capillaries into the interstitial spaces. The findings of other authors, which differ somewhat, are discussed. (orig.) [de

  4. Generalized Born Models of Macromolecular Solvation Effects

    Science.gov (United States)

    Bashford, Donald; Case, David A.

    2000-10-01

    It would often be useful in computer simulations to use a simple description of solvation effects, instead of explicitly representing the individual solvent molecules. Continuum dielectric models often work well in describing the thermodynamic aspects of aqueous solvation, and approximations to such models that avoid the need to solve the Poisson equation are attractive because of their computational efficiency. Here we give an overview of one such approximation, the generalized Born model, which is simple and fast enough to be used for molecular dynamics simulations of proteins and nucleic acids. We discuss its strengths and weaknesses, both for its fidelity to the underlying continuum model and for its ability to replace explicit consideration of solvent molecules in macromolecular simulations. We focus particularly on versions of the generalized Born model that have a pair-wise analytical form, and therefore fit most naturally into conventional molecular mechanics calculations.

  5. Probing the hydration water diffusion of macromolecular surfaces and interfaces

    International Nuclear Information System (INIS)

    Ortony, Julia H; Cheng, Chi-Yuan; Franck, John M; Pavlova, Anna; Hunt, Jasmine; Han, Songi; Kausik, Ravinath

    2011-01-01

    We probe the translational dynamics of the hydration water surrounding the macromolecular surfaces of selected polyelectrolytes, lipid vesicles and intrinsically disordered proteins with site specificity in aqueous solutions. These measurements are made possible by the recent development of a new instrumental and methodological approach based on Overhauser dynamic nuclear polarization (DNP)-enhanced nuclear magnetic resonance (NMR) spectroscopy. This technique selectively amplifies 1 H NMR signals of hydration water around a spin label that is attached to a molecular site of interest. The selective 1 H NMR amplification within molecular length scales of a spin label is achieved by utilizing short-distance range (∼r -3 ) magnetic dipolar interactions between the 1 H spin of water and the electron spin of a nitroxide radical-based label. Key features include the fact that only minute quantities (<10 μl) and dilute (≥100 μM) sample concentrations are needed. There is no size limit on the macromolecule or molecular assembly to be analyzed. Hydration water with translational correlation times between 10 and 800 ps is measured within ∼10 A distance of the spin label, encompassing the typical thickness of a hydration layer with three water molecules across. The hydration water moving within this time scale has significant implications, as this is what is modulated whenever macromolecules or molecular assemblies undergo interactions, binding or conformational changes. We demonstrate, with the examples of polymer complexation, protein aggregation and lipid-polymer interaction, that the measurements of interfacial hydration dynamics can sensitively and site specifically probe macromolecular interactions.

  6. Endovascular revascularization of TASC C and D femoropopliteal occlusive disease using carbon dioxide as contrast

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Cynthia de Almeida; Teivelis, Marcelo Passos; Kuzniec, Sergio; Fukuda, Juliana Maria; Wolosker, Nelson [Hospital Israelita Albert Einstein, São Paulo, SP (Brazil)

    2016-07-01

    To analyze the results of ten angioplasties of TASC C and D femoropopliteal lesions using CO{sub 2} as primary contrast in patients with no formal contraindication to iodine, aiming to decrease allergic reactions and potential nephrotoxicity in high-risk patients. We describe the results of ten angioplasties of TASC C and D femoropopliteal lesions using CO{sub 2} as primary contrast in patients with high risk for open revascularization and no formal contraindication to iodine. We analyzed feasibility of the procedures, complications, quality of the angiographic images, clinical and surgical outcomes, and costs of C and D lesions treated using CO{sub 2} as contrast medium. The use of CO{sub 2} in C and D lesions needed iodine complementation in most of the cases (nine cases) but decreased the potential nephrotoxicity of iodine contrast medium by the reduction of its volume in this group of high-risk patients. The extension of the arterial lesions was the factor that most contributed to the need for iodine supplementation due to the difficulty to visualize the refill after a long arterial occlusion. The use of CO{sub 2} as contrast in patients with C and D lesions with no restriction for iodine contrast medium was an alternative that did not dismiss the need of iodine supplementation in most of the cases, but could decrease the potential nephrotoxicity of iodine constrast medium.

  7. Automatic Time Sequence Alignment in Contrast Enhanced MRI by Maximization of Mutual Information

    National Research Council Canada - National Science Library

    Positano, Vicenzo

    2001-01-01

    The use of contrast medium allows joining the high-resolution anatomical information provided by standard magnetic resonance with functional information obtained by means of the diffusion of contrast...

  8. Equilibrium-phase MR angiography: Comparison of unspecific extracellular and protein-binding gadolinium-based contrast media with respect to image quality.

    Science.gov (United States)

    Erb-Eigner, Katharina; Taupitz, Matthias; Asbach, Patrick

    2016-01-01

    The purpose of this study was to compare contrast and image quality of whole-body equilibrium-phase high-spatial-resolution MR angiography using a non-protein-binding unspecific extracellular gadolinium-based contrast medium with that of two contrast media with different protein-binding properties. 45 patients were examined using either 15 mL of gadobutrol (non-protein-binding, n = 15), 32 mL of gadobenate dimeglumine (weakly protein binding, n = 15) or 11 mL gadofosveset trisodium (protein binding, n = 15) followed by equilibrium-phase high-spatial-resolution MR-angiography of four consecutive anatomic regions. The time elapsed between the contrast injection and the beginning of the equilibrium-phase image acquisition in the respective region was measured and was up to 21 min. Signal intensity was measured in two vessels per region and in muscle tissue. Relative contrast (RC) values were calculated. Vessel contrast, artifacts and image quality were rated by two radiologists in consensus on a five-point scale. Compared with gadobutrol, gadofosveset trisodium revealed significantly higher RC values only when acquired later than 15 min after bolus injection. Otherwise, no significant differences between the three contrast media were found regarding vascular contrast and image quality. Equilibrium-phase high-spatial-resolution MR-angiography using a weakly protein-binding or even non-protein-binding contrast medium is equivalent to using a stronger protein-binding contrast medium when image acquisition is within the first 15 min after contrast injection, and allows depiction of the vasculature with high contrast and image quality. The protein-binding contrast medium was superior for imaging only later than 15 min after contrast medium injection. Copyright © 2015 John Wiley & Sons, Ltd.

  9. High-pitch coronary CT angiography at 70 kVp adopting a protocol of low injection speed and low volume of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Ruiqi; Liu, Xiao Fei; Zhao, Yu; Zhang, Liang [Dept. of Radiology, The First Affiliated Hospital of China Medical University, Shenyang (China); Tong, Jia Jie [Dept. of Radiology, Hebei General Hospital, Shijiazhuang(China)

    2017-09-15

    To evaluate the feasibility and image quality (IQ) of prospectively high-pitch coronary CT angiography (CCTA) with low contrast medium injection rate at 70 kVp. One hundred and four patients with suspected coronary artery disease (body mass index < 26 kg/m{sup 2}, sinus rhythm and heart rate < 70 beats/min) were prospectively enrolled and randomly divided into two groups. In group A and group B, 28 mL and 40 mL of 370 mgI/mL iodinated contrast media was administrated at a flow rate of 3.5 and 5 mL/s, respectively. CT values, noise, signal-to-noise ratio, contrast-to-noise ratio (CNR) of the proximal segments of coronary arteries and subjective IQ were evaluated. The CT values and noise in group A were significantly lower than those in group B (434–485 Hounsfield units [HU] vs. 772–851 HU, all p < 0.001; 17.8–22.3 vs. 23.3–26.4, all p < 0.005). The CNRs of the right coronary artery and left main artery showed no statistical difference between the two groups (42.1 ± 13.8 vs. 36.8 ± 16.0, p = 0.074; 38.7 ± 10.6 vs. 38.1 ± 17.0, p = 0.819). No statistical difference was observed between the two groups in IQ scores (3.04 ± 0.75 vs. 3.0 ± 0.79, p = 0.526) and diagnostic ratio (96.1% [50/52] vs. 94.2% [49/52], p = 0.647). Prospective high-pitch CCTA at 70 kVp with 28 mL of contrast media and injection rate of 3.5 mL/s could provide diagnostic IQ for normal-weight patients with heart rate of < 70 beats/min.

  10. An evaluation of ultravist - a contrast medium by Schering in angiography

    International Nuclear Information System (INIS)

    Twarkowski, P.; Woynarowski, M.

    1993-01-01

    An angiography with ''uropolina'' (Polfa), ''hexabrix'' (Byk) and ''ultravist'' (Schering) was performed in 30 patients with various vascular disorders. It has appeared, that low-osmolality contrast media (''hexabrix'') and nonionic ones (''ultravist'') less frequently caused the complications than ''uropolina'', widely used by us. (author)

  11. Measurement and Interpretation of Diffuse Scattering in X-Ray Diffraction for Macromolecular Crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Wall, Michael E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-16

    X-ray diffraction from macromolecular crystals includes both sharply peaked Bragg reflections and diffuse intensity between the peaks. The information in Bragg scattering reflects the mean electron density in the unit cells of the crystal. The diffuse scattering arises from correlations in the variations of electron density that may occur from one unit cell to another, and therefore contains information about collective motions in proteins.

  12. Gadolinium-DTPA as an oral contrast medium for MR tomography of the abdomen

    International Nuclear Information System (INIS)

    Krahe, T.; Doelken, W.; Lackner, K.; Houselog, M.

    1990-01-01

    150 MR examinations of the upper abdomen were carried out after the oral administration of 5 ml/kg body weight of a gadolinium DTPA formulation (1.0 mmol/l, 15 g/l manitol), with reference to the delineation of the pancreas, the liver and intra-abdominal fat. For comparison, 100 MR examinations without oral opacification of the G.I. tract were evaluated. Contrast administration resulted in a signal-intensive demonstration of the G.I tract for all measurement sequences. The intraluminal contrast improved the distinction between normal and abnormal structures, T 1 and T 2 sequences and the demonstration of fat on T 2 -weighted series. T 1 -weighted series showed the best diagnostic results. In 25% there was meteorism and diarrhoea within 24 hours of the administration of the oral contrast. (orig.) [de

  13. Proceedings of a one-week course on exploiting anomalous scattering in macromolecular structure determination (EMBO'07)

    International Nuclear Information System (INIS)

    Weiss, M.S.; Shepard, W.; Dauter, Z.; Leslie, A.; Diederichs, K.; Evans, G.; Svensson, O.; Schneider, T.; Bricogne, G.; Dauter, Z.; Flensburg, C.; Terwilliger, T.; Lamzin, V.; Leslie, A.; Kabsch, W.; Flensburg, C.; Terwilliger, T.; Lamzin, V.; Read, R.; Panjikar, S.; Pannu, N.S.; Dauter, Z.; Weiss, M.S.; McSweeney, S.

    2007-01-01

    This course, which was directed to young scientists, illustrated both theoretical and practical aspects of macromolecular crystal structure solution using synchrotron radiation. Some software dedicated to data collection, processing and analysis were presented. This document gathers only the slides of the presentations

  14. Proceedings of a one-week course on exploiting anomalous scattering in macromolecular structure determination (EMBO'07)

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, M S; Shepard, W; Dauter, Z; Leslie, A; Diederichs, K; Evans, G; Svensson, O; Schneider, T; Bricogne, G; Dauter, Z; Flensburg, C; Terwilliger, T; Lamzin, V; Leslie, A; Kabsch, W; Flensburg, C; Terwilliger, T; Lamzin, V; Read, R; Panjikar, S; Pannu, N S; Dauter, Z; Weiss, M S; McSweeney, S

    2007-07-01

    This course, which was directed to young scientists, illustrated both theoretical and practical aspects of macromolecular crystal structure solution using synchrotron radiation. Some software dedicated to data collection, processing and analysis were presented. This document gathers only the slides of the presentations.

  15. Prevention of adverse reactions to intravascular contrast media

    International Nuclear Information System (INIS)

    Soyer, P.; Levesque, M.

    1990-01-01

    The exact mechanisms of adverse reactions to contrast media are still imperfectly known. However, these reactions may be classified as idiosyncratic. Non-idiosyncratic reactions can be prevented by using new, non-ionic contrast agents. Idiosyncratic reactions can be prevented by specific premedication. Patients with a history of idiosyncratic reaction may benefit from corticosteroids and antihistamines administered prophylactically. Patients who seem to be more likely than others to react to contrast media must be premedicated, the risk of reaction being identified and evaluated by questioning. It has recently been suggested that all patients about to receive an intravascular injection of contrast medium should also be premedicated [fr

  16. Bioadhesive agents in addition to oral contrast media - evaluation in an animal model

    International Nuclear Information System (INIS)

    Conrad, R.; Schneider, G.; Textor, J.; Schild, H.H.; Fimmers, R.

    1998-01-01

    Purpose: To evaluate the additional effect of bioadhesives in combination with iotrolan and barium as oral contrast media in an animal model. Method: The bioadhesives Noveon, CMC, Tylose and Carbopol 934 were added to iotrolan and barium. The solutions were administered to rabbits by a feeding tube. The animals were investigated by computed tomography (CT) and radiography after 0,5, 4, 12, 24 and in part after 48 hours. Mucosal coating and contrast filling of the bowel were evaluated. Results: Addition of bioadhesives to oral contrast media effected long-term contrast in the small intestine and colon, but no improvement in continuous filling and coating of the gastrointestinal tract was detected. Mucosal coating was seen only in short regions of the caecum and small intestine. In CT the best results for coating were observed with tylose and CMC, in radiography additionally with carbopol and noveon. All contrast medium solutions were well tolerated. Conclusion: The evaluated contrast medium solutions with bioadhesives have shown long-term contrast but no improvement in coating in comparison to conventional oral contrast media. (orig.) [de

  17. Polycapillary x-ray optics for macromolecular crystallography

    International Nuclear Information System (INIS)

    Owens, S.M.; Gibson, W.M.; Carter, D.C.; Sisk, R.C.; Ho, J.X.

    1996-01-01

    Polycapillary x-ray optics have found potential application in many different fields, including antiscatter and magnification in mammography, radiography, x-ray fluorescence, x-ray lithography, and x-ray diffraction techniques. In x-ray diffraction, an optic is used to collect divergent x-rays from a point source and redirect them into a quasi-parallel, or slightly focused beam. Monolithic polycapillary optics have been developed recently for macromolecular crystallography and have already shown considerable gains in diffracted beam intensity over pinhole collimation. Development is being pursued through a series of simulations and prototype optics. Many improvements have been made over the stage 1 prototype reported previously, which include better control over the manufacturing process, reducing the diameter of the output beam, and addition of a slight focusing at the output of the optic to further increase x-ray flux at the sample. The authors report the characteristics and performance of the stage 1 and stage 2 optics

  18. The experimental study of the effect of dexamethasone, lidocaine and contrast medium on the activity of collagenase

    International Nuclear Information System (INIS)

    Wu Zhiqun; Liu Weimin; Li Zhonghua; Yang Peng

    2007-01-01

    Objective: To study the effects of hormone, anesthetic and contrast medium on the activities of collagenase lysis. Methods: Nuclear tissues were divided into equal amount for different groups and same units of collagenase were used for the lysis. The only difference in the control group from experimental groups was that there were no dexamethasone, lidocaine or omnipaque but existing in experimental groups. Twenty four hours later, the concentrations of the hydroxyproline were determined in different groups and the data were analyzed by statistical software with computer. Results: 1. The concentrations of hydroxyproline in the dexamethasone group, lidocaine group and omnipaque group were significantly lower than that of control group, especially that of lidocaine group, P value was <0.05 or 0.01. 2. The concentrations of hydroxyproline in the dexamethasone + lidocaine group, dexamethasone + omnipaque group, lidocaine+omnipaque group and dexamethasone + lidocaine + omnipaque group were significantly lower than that of control group; and simultaneously lower in dexamethasone group, lidocaine group, omnipaque group respectively; P value was also <0.05 or 0.01. Conclusion: Dexamethasone, lidocaine and omnipaque can individually inhibit the activity of collagenase at different degrees, so they shouldn't be used together with collagenase in treating the lumber disc herniation. (authors)

  19. Use of Iodine-based contrast media in digital full-field mammography - initial experience

    International Nuclear Information System (INIS)

    Diekmann, F.; Diekmann, S.; Taupitz, M.; Bick, U.; Winzer, K.-J.; Huettner, C.; Muller, S.; Jeunehomme, F.; Hamm, B.

    2003-01-01

    Aim: To investigate the use of iodine-based contrast media in digital full-field mammography. Methods: After performing initial phantom studies, seven patients underwent digital mammography (Senographe 2000D, GE Medical Systems, Milwaukee, USA) using a specially filtered beam before as well as 60, 120, and 180 seconds after injection of 80 ml of iodine contrast medium (Ultravist 370, Schering AG, Germany). The precontrast mammograms were then subtracted from the postcontrast mammograms and the resulting images compared with a contrast-enhanced dynamic MRI study, performed on all women. Results: Contrast medium accumulation within the tumors was visualized with a good quality in all cases. The conditions under which successful contrast-enhanced digital mammography can be performed were determined in phantom studies. Conclusions: Contrast-enhanced digital mammography has a potential for improving the visualization of breast tumors in mammography using special beam filtering, adjusted X-ray parameters, proper timing, and suitable subtraction software. (orig.) [de

  20. The Postgraduate Study of Macromolecular Sciences at the University of Zagreb (1971-1980)

    OpenAIRE

    Kunst, B.; Dezelic, D.; Veksli, Z.

    2008-01-01

    The postgraduate study of macromolecular sciences (PSMS) was established at the University of Zagreb in 1971 as a university study in the time of expressed interdisciplinary permeation of natural sciences - physics, chemistry and biology, and application of their achievements in technologicaldisciplines. PSMS was established by a group of prominent university professors from the schools of Science, Chemical Technology, Pharmacy and Medicine, as well as from the Institute of Biology. The study...

  1. A decade of user operation on the macromolecular crystallography MAD beamline ID14-4 at the ESRF

    International Nuclear Information System (INIS)

    McCarthy, Andrew A.; Brockhauser, Sandor; Nurizzo, Didier; Theveneau, Pascal; Mairs, Trevor; Spruce, Darren; Guijarro, Matias; Lesourd, Marc; Ravelli, Raimond B. G.; McSweeney, Sean

    2009-01-01

    The improvement of the X-ray beam quality achieved on ID14-4 by the installation of new X-ray optical elements is described. ID14-4 at the ESRF is the first tunable undulator-based macromolecular crystallography beamline that can celebrate a decade of user service. During this time ID14-4 has not only been instrumental in the determination of the structures of biologically important molecules but has also contributed significantly to the development of various instruments, novel data collection schemes and pioneering radiation damage studies on biological samples. Here, the evolution of ID14-4 over the last decade is presented, and some of the major improvements that were carried out in order to maintain its status as one of the most productive macromolecular crystallography beamlines are highlighted. The experimental hutch has been upgraded to accommodate a high-precision diffractometer, a sample changer and a large CCD detector. More recently, the optical hutch has been refurbished in order to improve the X-ray beam quality on ID14-4 and to incorporate the most modern and robust optical elements used at other ESRF beamlines. These new optical elements will be described and their effect on beam stability discussed. These studies may be useful in the design, construction and maintenance of future X-ray beamlines for macromolecular crystallography and indeed other applications, such as those planned for the ESRF upgrade

  2. Prevention of contrast-induced nephropathy by use of bicarbonate solution: preliminary results and literature review.

    Science.gov (United States)

    Silva, Ricardo Gonçalves da; Silva, Nelson Gonçalves da; Lucchesi, Fabiano; Burdmann, Emmanuel A

    2010-01-01

    The incidence of contrast-induced nephropathy has increased simultaneously with the increase in contrast medium use in diagnostic and interventional procedures. The incidence of contrast-induced nephropathy in the general population is low, but increases exponentially in patients with risk factors, such as diabetes and chronic kidney disease. Several strategies have been used in order to prevent contrast-induced nephropathy. The most efficient strategies are saline hydration (0.9% or 0.45%), use of low-or iso-osmolality contrast medium, and sodium bicarbonate infusion. The aim of this study was to review the pertinent literature and to assess the efficacy of hydration with 1.3% sodium bicarbonate compared with hydration with 0.9% saline solution in preventing contrast-induced nephropathy in high-risk patients. A systematic search of the literature was conducted in PubMed by using the following keywords: bicarbonate, nephropathy, contrast medium, and acute kidney failure. In addition, 27 patients with diabetes and/or chronic kidney disease, diagnosed with some kind of cancer were randomized for study. None of the patients developed contrast-induced nephropathy characterized as a 0.5 mg/ dL-increase and/or a relative 25%-increase in baseline creatinine. The literature review strongly suggested that sodium bicarbonate is effective in preventing contrast-induced nephropathy. Regarding the randomized study, saline solution and bicarbonate solution had similar efficacy in preventing contrast-induced nephropathy. However, the small number of patients does not allow definite conclusions.

  3. The Preinterventional Cystatin-Creatinine-Ratio: A Prognostic Marker for Contrast Medium-Induced Acute Kidney Injury and Long-Term All-Cause Mortality.

    Science.gov (United States)

    Lüders, Florian; Meyborg, Matthias; Malyar, Nasser; Reinecke, Holger

    2015-01-01

    Contrast medium-induced acute kidney injury (CI-AKI) is an important iatrogenic complication following the injection of iodinated contrast media. The level of serum creatinine (SCr) is the currently accepted 'gold standard' to diagnose CI-AKI. Cystatin C (CyC) has been detected as a more sensitive marker for renal dysfunction. Both have their limitations. The role of the preinterventional CyC-SCr ratio for evaluating the risk for CI-AKI and long-term all-cause mortality was retrospectively analyzed in the prospective single-center 'Dialysis-versus-Diuresis trial'. CI-AKI was defined and staged according to the Acute Kidney Injury Network classification. Three hundred and seventy-three patients were included (average age 67.4 ± 10.2 years, 16.4% women, 29.2% with diabetes mellitus, mean baseline glomerular filtration rate 56.3 ± 20.2 ml/min/1.73 m(2) [as estimated by Chronic Kidney Disease Epidemiology Collaboration Serum Creatinine Cystatin C equation], 5.1% ejection fraction high significant association between preinterventional CyC-SCr ratio and long-term all-cause mortality (mean follow-up 649 days, hazards ratio 4.096, 95% CI 1.625-10.329, p = 0.003). The preinterventional CyC-SCr ratio is independently associated with CI-AKI and highly significant associated with long-term mortality after heart catheterization. © 2015 S. Karger AG, Basel.

  4. Myelography in the dog with non-ionic contrast media at different iodine concentrations

    International Nuclear Information System (INIS)

    Fatone, G.; Lamagna, F.; Pasolini, M.P.; Potena, A.; Brunetti, A.

    1997-01-01

    Image quality and side effects were evaluated retrospectively in a series of 183 myelographic studies performed with two non-ionic contrast media (iohexol and iopamidol) at different concentrations. Side effects during and following the procedure were recorded. Image quality was assessed using an arbitrary scoring system and statistical analysis was performed with the cross-tabulation test (4 times 2 table) by comparing two groups receiving contrast medium at higher and lower concentrations. No significant differences in side effects were observed between the two groups but the ratings for image quality were significantly higher in the group receiving contrast medium at the higher concentration than in the group receiving the lower concentration. The results suggest that a high concentration of non-ionic contrast media can safely be used in dogs and may improve image quality

  5. Pharmacodynamics and tolerance of X-ray contrast media

    International Nuclear Information System (INIS)

    Schmiedel, E.

    1987-01-01

    The improved tolerance of nonionic contrast media compared with conventional contrast media is mainly due to their lower osmolality and reduced allergoid potential. Tolerance advantages that have been definitely proven are, for example, low-pain contrast medium injection and superior systemic tolerance; side effects of an allergic pattern occur less often. Animals experiments have established that nonionic contrast media exercise a comparatively lower influence on the cardiovascular system. The haemodynamics of pulmonary circulation are less adversely affected on intravenous bolus injection. Reduced potential risk is to be expected especially in cardiac and bronchopulmonary high-risk patients. The reduced nephrotoxicity of nonionic contrast media was definitely established by clinical studies. Further systematic studies will however be required to provide an answer to the question whether this also entails a reduction in the incidence of renal failures induced by contrast media. (orig.) [de

  6. Peripheral blood eosinophilia associated with gastrointestinal administration of iodinated contrast media.

    Science.gov (United States)

    Plavsic, Branko M; Newman, Alan C; Reuther, Warren L; Terry, James A; Drnovsek, Valerie H

    2003-03-01

    This study was designed to assess whether gastrointestinal administration of iodinated contrast media results in peripheral blood eosinophilia. We studied 110 patients in a retrospective review. Diatrizoate meglumine and diatrizoate sodium for abdominal CT were administered to 98 of these patients; 22 of the 98 had also been given the same contrast medium administered by enema. The remaining 12 patients were given diatrizoate sodium for gastrointestinal fluoroscopy. A control group of 65 patients underwent single-contrast barium upper gastrointestinal or enema examinations. WBC and eosinophil counts were determined approximately 24 hr before the examination and every 24 hr thereafter, through the ninth day. Eosinophilia was detected in 17 (15.5%) of 110 patients after gastrointestinal administration of iodinated contrast media. The prevalence of eosinophilia after administration of iodinated contrast media was statistically significantly different compared with that in the control group, in which none of the 65 patients had eosinophilia (p contrast agents and lasted through the sixth day, with a peak on the fifth day. The prevalence of eosinophilia was independent of route of application, dose, or type of iodinated contrast medium. Eosinophilia in all cases was clinically asymptomatic. Eosinophilia that is caused by gastrointestinal administration of iodinated contrast media is a transient, clinically silent phenomenon. It may lead to unnecessary workup for known conditions associated with eosinophilia.

  7. Adriamycin nephrosis and contrast media

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Golman, K.; Hemmingsen, L.; Larsen, S.; Skaarup, P.; Koebenhavns Amts Sygehus, Herlev; Koebenhavns Amts Sygehus, Herlev; Centralsygehuset, Nykoebing Falster; Malmoe Allmaenna Sjukhus

    1990-01-01

    Urine profiles (albumin, glucose, NAG, LDH, GGT and sodium) were followed for 9 days after intravenous injection of either diatrizoate, iohexol, or saline in 27 Wistar rats with nephrosis induced by Adriamycin 42 days before. Another 9 rats exposed to neither Adriamycin nor contrast media served as controls. None of the contrast media caused further increased albuminuria of significance, whereas both induced significantly increased excretion of all 5 tubular components. The excretion of NAG and sodium was significantly higher following diatrizoate than following iohexol. From 24 h post injection there was no significantly greater excretion of any of the components after either diatrizoate or iohexol than after saline among the rats given Adriamycin. At the end of day 9 after contrast medium injection neither serum sodium, potassium, glucose, urea, creatinine, nor albumin revealed any contrast media related changes. Kidney histology showed quantitatively larger lesions in kidneys exposed to Adriamycin and contrast media than in kidneys exposed to Adriamycin and saline. There were no differences between the two contrast media groups. It is thus concluded, that both high osmolar ionic and low osmolar non-ionic contrast media cause temporary tubular dysfunction but no further glomerular dysfunction in rats with nephrosis induced by Adriamycin. The histologic findings indicate that both media may worsen non-reversible renal lesions. (orig.)

  8. A Web Resource for Standardized Benchmark Datasets, Metrics, and Rosetta Protocols for Macromolecular Modeling and Design.

    Directory of Open Access Journals (Sweden)

    Shane Ó Conchúir

    Full Text Available The development and validation of computational macromolecular modeling and design methods depend on suitable benchmark datasets and informative metrics for comparing protocols. In addition, if a method is intended to be adopted broadly in diverse biological applications, there needs to be information on appropriate parameters for each protocol, as well as metrics describing the expected accuracy compared to experimental data. In certain disciplines, there exist established benchmarks and public resources where experts in a particular methodology are encouraged to supply their most efficient implementation of each particular benchmark. We aim to provide such a resource for protocols in macromolecular modeling and design. We present a freely accessible web resource (https://kortemmelab.ucsf.edu/benchmarks to guide the development of protocols for protein modeling and design. The site provides benchmark datasets and metrics to compare the performance of a variety of modeling protocols using different computational sampling methods and energy functions, providing a "best practice" set of parameters for each method. Each benchmark has an associated downloadable benchmark capture archive containing the input files, analysis scripts, and tutorials for running the benchmark. The captures may be run with any suitable modeling method; we supply command lines for running the benchmarks using the Rosetta software suite. We have compiled initial benchmarks for the resource spanning three key areas: prediction of energetic effects of mutations, protein design, and protein structure prediction, each with associated state-of-the-art modeling protocols. With the help of the wider macromolecular modeling community, we hope to expand the variety of benchmarks included on the website and continue to evaluate new iterations of current methods as they become available.

  9. Macromolecular crowding compacts unfolded apoflavodoxin and causes severe aggregation of the off-pathway intermediate during apoflavodoxin folding

    NARCIS (Netherlands)

    Engel, R.; Westphal, A.H.; Huberts, D.; Nabuurs, S.M.; Lindhoud, S.; Visser, A.J.W.G.; Mierlo, van C.P.M.

    2008-01-01

    To understand how proteins fold in vivo, it is important to investigate the effects of macromolecular crowding on protein folding. Here, the influence of crowding on in vitro apoflavodoxin folding, which involves a relatively stable off-pathway intermediate with molten globule characteristics, is

  10. Proceedings of a one-week course on exploiting anomalous scattering in macromolecular structure determination (EMBO'07)

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, M.S.; Shepard, W.; Dauter, Z.; Leslie, A.; Diederichs, K.; Evans, G.; Svensson, O.; Schneider, T.; Bricogne, G.; Dauter, Z.; Flensburg, C.; Terwilliger, T.; Lamzin, V.; Leslie, A.; Kabsch, W.; Flensburg, C.; Terwilliger, T.; Lamzin, V.; Read, R.; Panjikar, S.; Pannu, N.S.; Dauter, Z.; Weiss, M.S.; McSweeney, S

    2007-07-01

    This course, which was directed to young scientists, illustrated both theoretical and practical aspects of macromolecular crystal structure solution using synchrotron radiation. Some software dedicated to data collection, processing and analysis were presented. This document gathers only the slides of the presentations.

  11. Probing the Interplay of Size, Shape, and Solution Environment in Macromolecular Diffusion Using a Simple Refraction Experiment

    Science.gov (United States)

    Mankidy, Bijith D.; Coutinho, Cecil A.; Gupta, Vinay K.

    2010-01-01

    The diffusion coefficient of polymers is a critical parameter in biomedicine, catalysis, chemical separations, nanotechnology, and other industrial applications. Here, measurement of macromolecular diffusion in solutions is described using a visually instructive, undergraduate-level optical refraction experiment based on Weiner's method. To…

  12. C,N-2-[(Dimethylamino)methyl]phenylplatinum Complexes Functionalized with C60 as Macromolecular Building Blocks

    NARCIS (Netherlands)

    Koten, G. van; Meijer, M.D.; Wolf, E. de; Lutz, M.H.; Spek, A.L.; Klink, G.P.M. van

    2001-01-01

    The application of platinum(II) complexes based on the N,N-dimethylbenzylamine ligand (abbreviated as H-C,N) in macromolecular synthesis was demonstrated. Two cationic C,N-platinum moieties were linked with a 4,4'-bipyridine bridge, giving [{C6H4(CH2NMe2)-2-Pt(PPh3)}2(4,4'-bpy)](BF4)2 (2), the

  13. Grain sorghum dust increases macromolecular efflux from the in situ nasal mucosa.

    Science.gov (United States)

    Gao, X P

    1998-04-01

    The purpose of this study was to determine whether an aqueous extract of grain sorghum dust increases macromolecular efflux from the nasal mucosa in vivo and, if so, whether this response is mediated, in part, by substance P. Suffusion of grain sorghum dust extract on the in situ nasal mucosa of anesthetized hamsters elicits a significant increase in clearance of fluorescein isothiocyanate-labeled dextran (FITC-dextran; mol mass, 70 kDa; P grain sorghum dust elicits neurogenic plasma exudation from the in situ nasal mucosa.

  14. Remote Access to the PXRR Macromolecular Crystallography Facilities at the NSLS

    Energy Technology Data Exchange (ETDEWEB)

    A Soares; D Schneider; J Skinner; M Cowan; R Buono; H Robinson; A Heroux; M Carlucci-Dayton; A Saxena; R Sweet

    2011-12-31

    The most recent surge of innovations that have simplified and streamlined the process of determining macromolecular structures by crystallography owes much to the efforts of the structural genomics community. However, this was only the last step in a long evolution that saw the metamorphosis of crystallography from an heroic effort that involved years of dedication and skill into a straightforward measurement that is occasionally almost trivial. Many of the steps in this remarkable odyssey involved reducing the physical labor that is demanded of experimenters in the field. Other steps reduced the technical expertise required for conducting those experiments.

  15. Remote Access to the PXRR Macromolecular Crystallography Facilities at the NSLS

    International Nuclear Information System (INIS)

    Soares, A.; Schneider, D.; Skinner, J.; Cowan, M.; Buono, R.; Robinson, H.; Heroux, A.; Carlucci-Dayton, M.; Saxena, A.; Sweet, R.

    2008-01-01

    The most recent surge of innovations that have simplified and streamlined the process of determining macromolecular structures by crystallography owes much to the efforts of the structural genomics community. However, this was only the last step in a long evolution that saw the metamorphosis of crystallography from an heroic effort that involved years of dedication and skill into a straightforward measurement that is occasionally almost trivial. Many of the steps in this remarkable odyssey involved reducing the physical labor that is demanded of experimenters in the field. Other steps reduced the technical expertise required for conducting those experiments.

  16. Development of a technique for contrast radiographic examination of the gastrointestinal tract in ball pythons (Python regius).

    Science.gov (United States)

    Banzato, Tommaso; Russo, Elisa; Finotti, Luca; Zotti, Alessandro

    2012-07-01

    To develop a technique for radiographic evaluation of the gastrointestinal tract in ball pythons (Python regius). 10 ball python cadavers (5 males and 5 females) and 18 healthy adult ball pythons (10 males and 8 females). Live snakes were allocated to 3 groups (A, B, and C). A dose (25 mL/kg) of barium sulfate suspension at 3 concentrations (25%, 35%, and 45% [wt/vol]) was administered through an esophageal probe to snakes in groups A, B, and C, respectively. Each evaluation ended when all the contrast medium had reached the large intestine. Transit times through the esophagus, stomach, and small intestine were recorded. Imaging quality was evaluated by 3 investigators who assigned a grading score on the basis of predetermined criteria. Statistical analysis was conducted to evaluate differences in quality among the study groups. The esophagus and stomach had a consistent distribution pattern of contrast medium, whereas 3 distribution patterns of contrast medium were identified in the small intestine, regardless of barium concentration. Significant differences in imaging quality were detected among the 3 groups. Radiographic procedures were tolerated well by all snakes. The 35% concentration of contrast medium yielded the best imaging quality. Use of contrast medium for evaluation of the cranial portion of the gastrointestinal tract could be a reliable technique for the diagnosis of gastrointestinal diseases in ball pythons. However, results of this study may not translate to other snake species because of variables identified in this group of snakes.

  17. Morphometric analysis of stab wounds by MSCT and MRI after the instillation of contrast medium.

    Science.gov (United States)

    Fais, Paolo; Cecchetto, Giovanni; Boscolo-Berto, Rafael; Toniolo, Matteo; Viel, Guido; Miotto, Diego; Montisci, Massimo; Tagliaro, Franco; Giraudo, Chiara

    2016-06-01

    To analyze the morphology and depth of stab wounds experimentally produced on human legs amputated for medical reasons using multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) after the instillation of a single contrast medium solution (CMS). For morphological analysis, MSCT and MRI scans were performed before and after the instillation of CMS into the wound cavity. Depth measurements were performed on the sagittal view only after CMS instillation. Subsequently, each wound was dissected using the layer-by-layer technique and the depth was measured by a ruler. One-way between-groups pairwise analysis of variance (ANOVA) and Bland-Altman plot analysis were used for comparing radiological and anatomical measurements. Unenhanced MSCT images did not identify the wound channels, whereas unenhanced MRI evidenced the wound cavity in 50 % of cases. After the instillation of CMS, both MSCT and MRI depicted the wound channel in all the investigated stabbings, although the morphology of the cavity was irregular and did not resemble the shape of the blade. The radiological measurements of the wounds' depth, after the application of CMS, exhibited a high level of agreement (about 95 % at Bland-Altman plot analysis) with the anatomical measurements at dissection. A similar systematic underestimation, however, has been evidenced for MSCT (average 11.4 %; 95 % CI 7-17) and MRI (average 9.6 %; 95 % CI 6-13) data after the instillation of CMS with respect to wound dissection measurements. MSCT and MRI after the instillation of CMS can be used for depicting the morphometric features of stab wounds, although depth measurements are affected by a slight systematic underestimation compared to layer-by-layer dissection.

  18. Local recurrence of rectal cancer: MR imaging before and after oral superparamagnetic particles vs contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Blomqvist, L.; Ohlsen, H.; Holm, T.

    2000-01-01

    The aim of this study was to compare three imaging strategies for the diagnosis of local recurrence of rectal cancer: (a) MR imaging; (b) MR imaging after administration of enteral superparamagnetic particles (Ferristene); and (c) contrast-enhanced CT. Seventeen patients with previous surgery for rectal cancer were examined, 12 patients with local tumour recurrence in the pelvis and 5 patients with postoperative changes. Pelvic multi-coil MR imaging before and after oral administration of superparamagnetic contrast medium [Abdoscan (Ferristene USAN), Nycomed-Amersham, Lidingoe, Sweden] as well as abdominal and pelvic CT was performed in all patients. The examinations were independently evaluated by three different radiologists. The general effect of the oral MR contrast medium, the delineation of normal and pathological structures as well as confidence in the diagnosis were registered on a visual analog scale (VAS). The diagnosis according to MR before and after oral contrast medium, and CT, was compared, in 16 patients, with the final diagnosis which was verified by biopsy (n = 3), surgery (n = 6), clinical follow-up (n = 4) and by follow-up with MR or CT (n = 3). No significant improvement in MR image quality was found after enteral contrast medium. The post-contrast MR diagnosis was not changed in any of the patients. The diagnosis on MR correlated with the final diagnosis in 12 of 16 patients (sensitivity 91 %, accuracy 62 %) and the diagnosis on CT in 11 of 16 patients (sensitivity 82 %, accuracy 56 %). The radiologists' ''confidence'' in the diagnosis and the degree of accordance with the final diagnosis did not score higher on MR after than before oral contrast administration; however, the accordance with the final diagnosis scored better on MR than on CT. No advantages of orally administered superparamagnetic contrast medium were observed in the examined patient group. Magnetic resonance is preferable to CT in diagnosing local tumour recurrence. (orig.)

  19. Comparative study of pneumocystography, positive contrast cystography and double contrast cystography in dogs

    International Nuclear Information System (INIS)

    Thibaut, J.; Parada, E.; Vargas, L.; Deppe, R.; Born, R.

    1997-01-01

    In order to compare three radiographic techniques: pneumocystography, positive contrast cystography and double contrast cystography, three series of 24 radiographs each in lateral and ventrodorsal projections were made. Six healthy adult male dogs with weight ranging between 7 and 16 kg were used. Food was withheld for 24 hours and two enemas were made before the series of radiographs were taken. Dogs were anaesthetized with sodium thiopental (20 mg/kg i.v.). The contrast medium was introduced through a urethral catheter. Pneumocystography was performed in the first series introducing air (10 ml/kg) in the bladder. Positive contrast cystography was performed in the second series introducing Hypaque M-60% diluted, contributing 100 mg of iodine per ml (10 ml/kg). In the double contrast cystography Hypaque M-60% diluted (10 ml) was introduced, in concentration of 150 mg of iodine per ml. Then air was introduced (10 ml/kg) through a catheter. Plates were taken in both projections at 1 and 10 minutes for each technique. The radiographic plates of each series were analized comparing the characteristics of radiographic density, outline and size. In neumocystography, positive contrast and double contrast cystography, the radiographic density was predominantly low, high and intermediate, respectively. The radiographic outline was mainly regular for the three techniques. With respect to bladder size, there was a decrease of height and an increase of length and width at 10 minutes. Comparing these three radiographic techniques, it can be concluded that the one that best outlines the bladder mucosa is double contrast. Pneumocystography provides the best image for opaque structures and cystography best shows the position of the urinary bladder [es

  20. Efficient analysis of macromolecular rotational diffusion from heteronuclear relaxation data

    International Nuclear Information System (INIS)

    Dosset, Patrice; Hus, Jean-Christophe; Blackledge, Martin; Marion, Dominique

    2000-01-01

    A novel program has been developed for the interpretation of 15 N relaxation rates in terms of macromolecular anisotropic rotational diffusion. The program is based on a highly efficient simulated annealing/minimization algorithm, designed specifically to search the parametric space described by the isotropic, axially symmetric and fully anisotropic rotational diffusion tensor models. The high efficiency of this algorithm allows extensive noise-based Monte Carlo error analysis. Relevant statistical tests are systematically applied to provide confidence limits for the proposed tensorial models. The program is illustrated here using the example of the cytochrome c' from Rhodobacter capsulatus, a four-helix bundle heme protein, for which data at three different field strengths were independently analysed and compared

  1. A study of contrast media on X-rays of upper GI examinations

    International Nuclear Information System (INIS)

    Beck, A.; Rupp, H.G.; Reinhold, W.D.; Grosser, G.

    1989-01-01

    700 gastro intestinal x-ray pictures were controlled by four independent radiologists. Three different baryum applications in patients examination were performed. The three baryum contrast-medium were Top-Contral, Mikropaque, (H-D Barium) and Titanate de Baryum. The examination technique in all patients was the same. In different sessions every radiologist was asked for his opinion about the regularity and thickness of the emulsion of contrast-medium, of the graph of the Areae gastricae, the sharpness of the stomach-contour and the production of bubbles. Finally to every picture it had to be done a qualification concerning to its presentation from 'insignificant' to 'excellent' in four degrees. The results: Excellent pictures could be done in the Esophagus with Titanate de Baryum. Best presentation of the stomach specially in double contrast could be done with Mikropaque, a quiet similar result was the examination with Top-Contral. There is no significant differentiation between contrasts-media in the small intestine. (orig.) [de

  2. 129 Xe NMR Relaxation-Based Macromolecular Sensing

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Muller D. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Dao, Phuong [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Jeong, Keunhong [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Slack, Clancy C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Vassiliou, Christophoros C. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Finbloom, Joel A. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Francis, Matthew B. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Wemmer, David E. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Physical Biosciences Division; Pines, Alexander [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division; Univ. of California, Berkeley, CA (United States). Dept. of Chemistry

    2016-07-29

    A 129Xe NMR relaxation-based sensing approach is reported on that exploits changes in the bulk xenon relaxation rate induced by slowed tumbling of a cryptophane-based sensor upon target binding. The amplification afforded by detection of the bulk dissolved xenon allows sensitive detection of targets. The sensor comprises a xenon-binding cryptophane cage, a target interaction element, and a metal chelating agent. Xenon associated with the target-bound cryptophane cage is rapidly relaxed and then detected after exchange with the bulk. Here we show that large macromolecular targets increase the rotational correlation time of xenon, increasing its relaxation rate. Upon binding of a biotin-containing sensor to avidin at 1.5 μM concentration, the free xenon T2 is reduced by a factor of 4.

  3. Use of spiral CT and the contrast medium iohexol to determine in one session aortorenal morphology and the relative glomerular filtration rate of each kidney

    International Nuclear Information System (INIS)

    Frennby, B.; Almen, T.

    2001-01-01

    The aim of this study was to determine the relative glomerular filtration rate (GFR), i.e. the GFR of each kidney in percent of total GFR, by spiral CT. In 41 patients, who were part of a follow-up program after endoluminal stent grafting of aortic aneurysm, spiral CT with the contrast medium iohexol was used to evaluate the morphology of the aorta and kidneys. The opportunity was taken to utilize the already injected iohexol to determine the relative GFR with an extra CT sequence. In each patient two determinations were made, 6 or 12 months apart. The amount of a GFR marker accumulating in Bowman's space, tubuli, and renal pelvis within 2-3 min after i.v. injection, before any marker had left the kidney via the ureter, was defined as proportional to the GFR of that kidney. The renal accumulation of iohexol was obtained by spiral CT using 10-mm collimation and a table speed of 10 mm/s (pitch ratio 1:1) from the upper to the lower poles. The correlation coefficient between the relative GFR of each kidney determined at the first and second examination was excellent (r=0.99) with a median (range) difference of 1% (0-6%) of total GFR. The radiation dose calculated as the mean absorbed dose to the kidneys was 50 mGy and the effective dose 5 mSv. The morphology of aorta and kidneys and the relative GFR of each kidney can be determined in one session with spiral CT using iohexol as both angiographic contrast medium and as a GFR marker. It is also possible to take some plasma samples in the same session to determine iohexol concentration to calculate the body clearance of iohexol (or take plasma and urine samples to calculate the renal clearance of iohexol). (orig.)

  4. Transport phenomena in sharply contrasting media with a diffusion barrier

    International Nuclear Information System (INIS)

    Dvoretskaya, O A; Kondratenko, P S

    2011-01-01

    Using the advection–diffusion equation, we analytically study contaminant transport in a sharply contrasting medium with a diffusion barrier due to localization of a contaminant source in a low-permeability medium. Anomalous diffusion behavior and a crossover between different transport regimes are observed. The diffusion barrier results in exponential attenuation of the source power, retardation of the contaminant plume growth and modification of the concentration distribution at large distances. (paper)

  5. Efficient optical Kerr gate of Bi2O3–B2O3–SiO2 glass for acquiring high contrast ballistic imaging in turbid medium

    International Nuclear Information System (INIS)

    Zhan, Pingping; Tan, Wenjiang; Wu, Bin; Si, Jinhai; Chen, Feng; Hou, Xun; Liu, Xin

    2013-01-01

    We investigated the ballistic imaging of a 1.41 line pair mm −1 section of a resolution test chart hidden behind a solution of polystyrene spheres with a femtosecond optical Kerr gate (OKG). A better transillumination image contrast could be acquired with an OKG of Bi 2 O 3 –B 2 O 3 –SiO 2 (BI) glass than that with an OKG of fused silica in a highly scattering media, which indicated that the BI glass was a better OKG medium due to its large nonlinear refractive index. (paper)

  6. Effect of prostaglandin inhibition on the renal vascular response to ionic and non-ionic contrast media in the dog

    International Nuclear Information System (INIS)

    Lund, G.; Einzig, S.; Rysavy, J.; Salomonowitz, E.; Castaneda-Zuniga, W.; Amplatz, K.; Minnesota Univ., Minneapolis

    1984-01-01

    In an attempt to study the role of prostaglandins in the renal vascular response to contrast media in mongrel dogs, renal arterial injections of 6 ml of either the non-ionic contrast medium Iopamidol or the ionic medium diatrizoate meglumine/Na + were performed, before and after intravenous injection of a buffered solution of acetyl-salicylic acid (10 mg/kg) (ASA). Renal blood flow was recorded using non-occluding electromagnetic flow probes. The resting renal blood flow was significantly reduced after ASA. The usual biphasic response to contrast injection was observed both before and after ASA, and using either contrast medium. Analysis of the results failed to show any difference in degree of vasodilation or vasoconstriction after ASA. We conclude that prostaglandins may affect the resting level of renal blood flow but are not mediators of the instantaneous changes in response to contrast injection. (orig.)

  7. Localization of protein aggregation in Escherichia coli is governed by diffusion and nucleoid macromolecular crowding effect.

    Directory of Open Access Journals (Sweden)

    Anne-Sophie Coquel

    2013-04-01

    Full Text Available Aggregates of misfolded proteins are a hallmark of many age-related diseases. Recently, they have been linked to aging of Escherichia coli (E. coli where protein aggregates accumulate at the old pole region of the aging bacterium. Because of the potential of E. coli as a model organism, elucidating aging and protein aggregation in this bacterium may pave the way to significant advances in our global understanding of aging. A first obstacle along this path is to decipher the mechanisms by which protein aggregates are targeted to specific intercellular locations. Here, using an integrated approach based on individual-based modeling, time-lapse fluorescence microscopy and automated image analysis, we show that the movement of aging-related protein aggregates in E. coli is purely diffusive (Brownian. Using single-particle tracking of protein aggregates in live E. coli cells, we estimated the average size and diffusion constant of the aggregates. Our results provide evidence that the aggregates passively diffuse within the cell, with diffusion constants that depend on their size in agreement with the Stokes-Einstein law. However, the aggregate displacements along the cell long axis are confined to a region that roughly corresponds to the nucleoid-free space in the cell pole, thus confirming the importance of increased macromolecular crowding in the nucleoids. We thus used 3D individual-based modeling to show that these three ingredients (diffusion, aggregation and diffusion hindrance in the nucleoids are sufficient and necessary to reproduce the available experimental data on aggregate localization in the cells. Taken together, our results strongly support the hypothesis that the localization of aging-related protein aggregates in the poles of E. coli results from the coupling of passive diffusion-aggregation with spatially non-homogeneous macromolecular crowding. They further support the importance of "soft" intracellular structuring (based on

  8. Prevention of generalized reactions to contrast media: a consensus report and guidelines

    International Nuclear Information System (INIS)

    Morcos, S.K.; Thomsen, H.S.; Webb, J.A.W.

    2001-01-01

    The aim of this study was to document, using consensus methodology, current practice for prevention of generalized reactions to contrast media, to identify areas where there is disagreement or confusion and to draw up guidelines for reducing the risk of generalized contrast media reactions based on the survey and a review of the literature. A document with 165 questions was mailed to 202 members of the European Society of Urogenital Radiology. The questions covered risk factors and prophylactic measures for generalized contrast media reactions. Sixty-eight members (34%) responded. The majority indicated that a history of moderate and severe reaction(s) to contrast media and asthma are important risk factors. The survey also indicated that patients with risk factors should receive non-ionic contrast media. In patients at high risk of reaction, if the examination is deemed absolutely necessary, a resuscitation team should be available at the time of the procedure. The majority (91%) used corticosteroid prophylaxis given at least 11 h before contrast medium to patients at increased risk of reaction. The frequency of the dosage varied from one to three times. Fifty-five percent also use antihistamine Hl, mainly administered orally and once. Antihistamine H2 and ephedrine are rarely used. All essential drugs are available on the emergency resuscitation trolley. Patients with risk factors are observed up to 30 min by 48% and up to 60 min by 43% of the responders. Prophylactic measures are not taken before extravascular use of contrast media. Prophylactic drugs are given to patients with a history of moderate or severe generalized reaction to contrast media. In patients with asthma, opinion is divided with only half of the responders giving prophylactic drugs. Aspirin, β-blockers, interleukin-2 and non-steroid anti-inflammatory drugs are not considered risk factors and therefore are not stopped before injection of contrast media. The survey showed some variability in

  9. Prevention of generalized reactions to contrast media: a consensus report and guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Morcos, S.K. [Dept. of Diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom); Thomsen, H.S. [Dept. of Diagnostic Radiology, Herlev Hospital, University of Copenhagen (Denmark); Webb, J.A.W. [Diagnostic Radiology Department, St. Bartholomew' s Hospital, London (United Kingdom)

    2001-09-01

    The aim of this study was to document, using consensus methodology, current practice for prevention of generalized reactions to contrast media, to identify areas where there is disagreement or confusion and to draw up guidelines for reducing the risk of generalized contrast media reactions based on the survey and a review of the literature. A document with 165 questions was mailed to 202 members of the European Society of Urogenital Radiology. The questions covered risk factors and prophylactic measures for generalized contrast media reactions. Sixty-eight members (34%) responded. The majority indicated that a history of moderate and severe reaction(s) to contrast media and asthma are important risk factors. The survey also indicated that patients with risk factors should receive non-ionic contrast media. In patients at high risk of reaction, if the examination is deemed absolutely necessary, a resuscitation team should be available at the time of the procedure. The majority (91%) used corticosteroid prophylaxis given at least 11 h before contrast medium to patients at increased risk of reaction. The frequency of the dosage varied from one to three times. Fifty-five percent also use antihistamine Hl, mainly administered orally and once. Antihistamine H2 and ephedrine are rarely used. All essential drugs are available on the emergency resuscitation trolley. Patients with risk factors are observed up to 30 min by 48% and up to 60 min by 43% of the responders. Prophylactic measures are not taken before extravascular use of contrast media. Prophylactic drugs are given to patients with a history of moderate or severe generalized reaction to contrast media. In patients with asthma, opinion is divided with only half of the responders giving prophylactic drugs. Aspirin, {beta}-blockers, interleukin-2 and non-steroid anti-inflammatory drugs are not considered risk factors and therefore are not stopped before injection of contrast media. The survey showed some variability in

  10. Macromolecular synthesis in algal cells

    International Nuclear Information System (INIS)

    Ishida, M.R.; Kikuchi, Tadatoshi

    1980-01-01

    The present paper is a review of our experimental results obtained previously on the macromolecular biosyntheses in the cells of blue-green alga Anacystis nidulans as a representative species of prokaryote, and also in those of three species of eukaryotic algae, i.e. Euglena gracilis strain Z, Chlamydomonas reinhardi, and Cyanidium caldarium. In these algal cells, the combined methods consisting of pulse-labelling using 32 P, 3 H- and 14 C-labelled precursors for macromolecules, of their chasing and of the use of inhibitors which block specifically the syntheses of macromolecules such as proteins, RNA and DNA in living cells were very effectively applied for the analyses of the regulatory mechanism in biosyntheses of macromolecules and of the mode of their assembly into the cell structure, especially organelle constituents. Rased on the results obtained thus, the following conclusions are reached: (1) the metabolic pool for syntheses of macromolecules in the cells of prokaryotic blue-green alga is limited to the small extent and such activities couple largely with the photosynthetic mechanism; (2) 70 S ribosomes in the blue-green algal cells are assembled on the surface of thylakoid membranes widely distributed in their cytoplasm; and (3) the cells of eukaryotic unicellular algae used here have biochemical characters specific for already differentiated enzyme system involving in transcription and translation machineries as the same as in higher organisms, but the control mechanism concerning with such macromolecule syntheses are different among each species. (author)

  11. Evaluation of macromolecular electron-density map quality using the correlation of local r.m.s. density

    International Nuclear Information System (INIS)

    Terwilliger, Thomas C.; Berendzen, Joel

    1999-01-01

    The correlation of local r.m.s. density is shown to be a good measure of the presence of distinct solvent and macromolecule regions in macromolecular electron-density maps. It has recently been shown that the standard deviation of local r.m.s. electron density is a good indicator of the presence of distinct regions of solvent and protein in macromolecular electron-density maps [Terwilliger & Berendzen (1999 ▶). Acta Cryst. D55, 501–505]. Here, it is demonstrated that a complementary measure, the correlation of local r.m.s. density in adjacent regions on the unit cell, is also a good measure of the presence of distinct solvent and protein regions. The correlation of local r.m.s. density is essentially a measure of how contiguous the solvent (and protein) regions are in the electron-density map. This statistic can be calculated in real space or in reciprocal space and has potential uses in evaluation of heavy-atom solutions in the MIR and MAD methods as well as for evaluation of trial phase sets in ab initio phasing procedures

  12. Correction of oral contrast artifacts in CT-based attenuation correction of PET images using an automated segmentation algorithm

    International Nuclear Information System (INIS)

    Ahmadian, Alireza; Ay, Mohammad R.; Sarkar, Saeed; Bidgoli, Javad H.; Zaidi, Habib

    2008-01-01

    Oral contrast is usually administered in most X-ray computed tomography (CT) examinations of the abdomen and the pelvis as it allows more accurate identification of the bowel and facilitates the interpretation of abdominal and pelvic CT studies. However, the misclassification of contrast medium with high-density bone in CT-based attenuation correction (CTAC) is known to generate artifacts in the attenuation map (μmap), thus resulting in overcorrection for attenuation of positron emission tomography (PET) images. In this study, we developed an automated algorithm for segmentation and classification of regions containing oral contrast medium to correct for artifacts in CT-attenuation-corrected PET images using the segmented contrast correction (SCC) algorithm. The proposed algorithm consists of two steps: first, high CT number object segmentation using combined region- and boundary-based segmentation and second, object classification to bone and contrast agent using a knowledge-based nonlinear fuzzy classifier. Thereafter, the CT numbers of pixels belonging to the region classified as contrast medium are substituted with their equivalent effective bone CT numbers using the SCC algorithm. The generated CT images are then down-sampled followed by Gaussian smoothing to match the resolution of PET images. A piecewise calibration curve was then used to convert CT pixel values to linear attenuation coefficients at 511 keV. The visual assessment of segmented regions performed by an experienced radiologist confirmed the accuracy of the segmentation and classification algorithms for delineation of contrast-enhanced regions in clinical CT images. The quantitative analysis of generated μmaps of 21 clinical CT colonoscopy datasets showed an overestimation ranging between 24.4% and 37.3% in the 3D-classified regions depending on their volume and the concentration of contrast medium. Two PET/CT studies known to be problematic demonstrated the applicability of the technique in

  13. A brief history of macromolecular crystallography, illustrated by a family tree and its Nobel fruits.

    Science.gov (United States)

    Jaskolski, Mariusz; Dauter, Zbigniew; Wlodawer, Alexander

    2014-09-01

    As a contribution to the celebration of the year 2014, declared by the United Nations to be 'The International Year of Crystallography', the FEBS Journal is dedicating this issue to papers showcasing the intimate union between macromolecular crystallography and structural biology, both in historical perspective and in current research. Instead of a formal editorial piece, by way of introduction, this review discusses the most important, often iconic, achievements of crystallographers that led to major advances in our understanding of the structure and function of biological macromolecules. We identified at least 42 scientists who received Nobel Prizes in Physics, Chemistry or Medicine for their contributions that included the use of X-rays or neutrons and crystallography, including 24 who made seminal discoveries in macromolecular sciences. Our spotlight is mostly, but not only, on the recipients of this most prestigious scientific honor, presented in approximately chronological order. As a summary of the review, we attempt to construct a genealogy tree of the principal lineages of protein crystallography, leading from the founding members to the present generation. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  14. The interaction of radiographic contrast media with immune globulins

    International Nuclear Information System (INIS)

    Bauer, K.

    1983-01-01

    As a special form of contrast medium incidents, various reaction modes between iodinated contrast media and immunoglobulins are described. Theoretical explanations and typical examples are given for each of the four different possible action mechanisms. Diagnostic precautions are proposed in order to avoid unfavourable reactions especially with paraproteins. Special attention is drawn to the antigen-antibody like reaction between iodinated contrast media and IgM paraproteins. Some immunological criteria are recalled to attention, this type of reaction has to meet stringently. Only by this, misinterpretations of inevident conclusions from analogy can be prevented in future similar cases. (orig.) [de

  15. Evaluation of the equine digital flexor tendon sheath using diagnostic ultrasound and contrast radiography

    International Nuclear Information System (INIS)

    Redding, W.R.

    1994-01-01

    This study was designed to evaluate the normal anatomy of the digital flexor tendon sheath using contrast radiography and diagnostic ultrasound. Iodinated contrast medium was injected into eight cadaver limbs and the limbs immediately frozen. Lateromedial and dorsopalmar/plantar radiographs were made. These limps were then cut transversely and proximal to distal radiographs of each slab were made. This cross sectional contrast methodology allowed the visualization of the relative size and shape of the superficial and deep digital flexor tendons as well as the potential space taken by effusions of the digital flexor tendon sheath. The second part of the study used twelve live animals with normal digital flexor tendon sheaths. Ultrasonographic measurement of the structures of the digital flexor tendon sheath at each level were compiled. This documented the ability of diagnostic ultrasound to image: 1) the superficial and deep digital flexor tendons, 2) the proximal and distal ring of the manica flexoria, 3) the straight and oblique sesamoidean ligaments, and 4) the mesotendinous attachments to the superficial and deep flexor tendons. Iodinated contrast medium was then injected into the digital flexor tendon sheath and the ultrasonography repeated. These images were compared with those obtained from contrast radiography and prosections of twenty normal limbs. The iodinated contrast medium enhanced sonographic imaging of the structures of the digital tendon sheath, particularly the abaxial borders of the superficial digital flexor tendon branches and the mesotendinous attachments to the superficial and deep digital flexor tendons

  16. Evaluation of quantum-chemical methods of radiolysis stability for macromolecular structures

    International Nuclear Information System (INIS)

    Postolache, Cristian; Matei, Lidia

    2005-01-01

    The behavior of macromolecular structures in ionising fields was analyzed by quantum-chemical methods. In this study the primary radiolytic effect was analyzed using a two-step radiolytic mechanism: a) ionisation of molecule and spatial redistribution of atoms in order to reach a minimum value of energy, characteristic to the quantum state; b) neutralisation of the molecule by electron capture and its rapid dissociation into free radicals. Chemical bonds suspected to break are located in the distribution region of LUMO orbital and have minimal homolytic dissociation energies. Representative polymer structures (polyethylene, polypropylene, polystyrene, poly α and β polystyrene, polyisobutylene, polytetrafluoroethylene, poly methylsiloxanes) were analyzed. (authors)

  17. Hepatic contrast medium enhancement at computed tomography and its correlation with various body size measures

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Nouhad, Jallo; Cederlund, Kerstin; Aspelin, Peter; Torkel, Brismar B., E-mail: anders.svensson@karolinska.se [Dept. of Clinical Science, Intervention and Technology at Karolinska Inst., Div. of Medical Imaging and Technology, Stockholm (Sweden); (Dept. of Radiology, Karolinska Univ. Hospital, Huddinge, Stockholm (Sweden)); Nyman, Ulf (Dept. of Diagnostic Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)); Bjoerk, Jonas (Competence Centre for Clinical Research, Skaane Univ. Hospital, Lund (Sweden)

    2012-07-15

    Background. When the same dose of iodine is given to all patients when performing abdominal computed tomography (CT) there may be a wide inter-individual variation in contrast medium (CM) enhancement of the liver. Purpose. To evaluate if any of the measures body height (BH), body mass index (BMI), lean body mass (LBM), ideal body weight (IBW), and body surface area (BSA) correlated better than body weight (BW) with hepatic enhancement, and to compare the enhancement when using iodixanol and iomeprol. Material and Methods. One hundred patients referred for standard three-phase CT examination of abdomen were enrolled. Body weight and height were measured at the time of the CT examination. Forty grams of iodine (iodixanol 320 mg I/mL or iomeprol 400 mg I/mL) was injected at a rate of 1.6 g-I/s, followed by a 50 mL saline flush. The late arterial phase was determined by using a semi-automatic smart prep technique with a scan delay of 20 s. The hepatic parenchymal phase started automatically 25 s after the late arterial phase. CM concentration was estimated by placement of regions of interest in aorta (native and late arterial phase) and in liver (native and parenchymal phase). Results. BW (r -0.51 and -0.64), LBM (r = -0.54 and -0.59), and BSA (r -0.54 and -0.65) showed the best correlation coefficients with aortic and hepatic parenchymal enhancement, respectively, without any significant differences between the measures. Comparing iodixanol and iomeprol there was no significant difference in aortic enhancement. The liver enhancement was significantly higher (P < 0.05) using iodixanol than iomeprol. Conclusion. To achieve a consistent hepatic enhancement, CM dose may simply be adjusted to body weight instead of using more complicated calculated parameters based on both weight and height.

  18. The Postgraduate Study of Macromolecular Sciences at the University of Zagreb (1971– 1980)

    OpenAIRE

    Deželić, D.; Kunst, B.; Veksli, Zorica

    2008-01-01

    The postgraduate study of macromolecular sciences (PSMS) was established at the University of Zagreb in 1971 as a university study in the time of expressed interdisciplinary permeation of natural sciences - physics, chemistry and biology, and application of their achievements in technological disciplines. PSMS was established by a group of prominent university professors from the schools of Science, Chemical Technology, Pharmacy and Medicine, as well as from the Institute of Biology. The s...

  19. Macromolecular Crystallization in Microfluidics for the International Space Station

    Science.gov (United States)

    Monaco, Lisa A.; Spearing, Scott

    2003-01-01

    At NASA's Marshall Space Flight Center, the Iterative Biological Crystallization (IBC) project has begun development on scientific hardware for macromolecular crystallization on the International Space Station (ISS). Currently ISS crystallization research is limited to solution recipes that were prepared on the ground prior to launch. The proposed hardware will conduct solution mixing and dispensing on board the ISS, be fully automated, and have imaging functions via remote commanding from the ground. Utilizing microfluidic technology, IBC will allow for on orbit iterations. The microfluidics LabChip(R) devices that have been developed, along with Caliper Technologies, will greatly benefit researchers by allowing for precise fluid handling of nano/pico liter sized volumes. IBC will maximize the amount of science return by utilizing the microfluidic approach and be a valuable tool to structural biologists investigating medically relevant projects.

  20. The monitoring system for macromolecular crystallography beamlines at BSRF

    International Nuclear Information System (INIS)

    Guo Xian; Chang Guangcai; Gan Quan; Shi Hong; Liu Peng; Sun Gongxing

    2012-01-01

    The monitoring system for macromolecular crystallography beamlines at BSRF (Beijing Synchrotron Radiation Facility) based on LabVIEW is introduced. In order to guarantee a safe, stable, and reliable running for the beamline devices, the system monitors the state of vacuum, cooling-water, optical components, beam, Liquid nitrogen in the beamlines in real time, detects faults and gives the alarm timely. System underlying uses the driver developed for the field devices for data acquisition, Data of collection is uploaded to the data-sharing platform makes it accessible via a network share. The upper system divides modules according to the actual function, and establishes the main interface of the monitoring system of beamline. To Facilitate data storage, management and inquiry, the system use LabSQL toolkit to achieve the interconnection with MySQL database which data of collection is sent to. (authors)

  1. The 2D Structure of the T. brucei Preedited RPS12 mRNA Is Not Affected by Macromolecular Crowding

    Directory of Open Access Journals (Sweden)

    W.-Matthias Leeder

    2017-01-01

    Full Text Available Mitochondrial transcript maturation in African trypanosomes requires RNA editing to convert sequence-deficient pre-mRNAs into translatable mRNAs. The different pre-mRNAs have been shown to adopt highly stable 2D folds; however, it is not known whether these structures resemble the in vivo folds given the extreme “crowding” conditions within the mitochondrion. Here, we analyze the effects of macromolecular crowding on the structure of the mitochondrial RPS12 pre-mRNA. We use high molecular mass polyethylene glycol as a macromolecular cosolute and monitor the structure of the RNA globally and with nucleotide resolution. We demonstrate that crowding has no impact on the 2D fold and we conclude that the MFE structure in dilute solvent conditions represents a good proxy for the folding of the pre-mRNA in its mitochondrial solvent context.

  2. Is the transport of a gadolinium-based contrast agent decreased in a degenerated or aged disc? A post contrast MRI study.

    Directory of Open Access Journals (Sweden)

    Marta Tibiletti

    Full Text Available A post contrast magnetic resonance imaging study has been performed in a wide population of low back pain patients to investigate which radiological and phenotypic characteristics influence the penetration of the contrast agent in lumbar discs in vivo. 37 patients affected by different pathologies (disc herniation, spondylolisthesis, foraminal stenosis, central canal stenosis were enrolled in the study. The selected population included 26 male and 11 female subjects, with a mean age of 42.4 ± 9.3 years (range 18-60. Magnetic resonance images of the lumbar spine were obtained with a 1.5 T scanner (Avanto, Siemens, Erlangen, Germany with a phased-array back coil. A paramagnetic non-ionic contrast agent was injected with a dose of 0.4 ml/kg. T1-weighted magnetic resonance images were subsequently acquired at 5 time points, 5 and 10 minutes, 2, 4 and 6 hours after injection. Endplates presented clear enhancement already 5 minutes after injection, and showed an increase in the next 2 hours followed by a decrease. At 5 and 10 minutes, virtually no contrast medium was present inside the intervertebral disc; afterwards, enhancement significantly increased. Highly degenerated discs showed higher enhancement in comparison with low and medium degenerated discs. Discs classified as Pfirrmann 5 showed a statistically significant higher enhancement than Pfirrmann 1, 2 and 3 at all time points but the first one, possibly due to vascularization. Disc height collapse and Modic changes significantly increased enhancement. Presence of endplate defects did not show any significant influence on post contrast enhancement, but the lack of a clear classification of endplate defects as seen on magnetic resonance scans may be shadowing some effects. In conclusion, disc height, high level of degeneration and presence of Modic changes are factors which increase post contrast enhancement in the intervertebral disc. The effect of age could not be demonstrated.

  3. Macromolecular Engineering: New Routes Towards the Synthesis of Well-??Defined Polyethers/Polyesters Co/Terpolymers with Different Architectures

    KAUST Repository

    Alamri, Haleema

    2016-05-18

    The primary objective of this research was to develop a new and efficient pathway for well-defined multicomponent homo/co/terpolymers of cyclic esters/ethers using an organocatalytic approach with an emphasis on the macromolecular engineering aspects of the overall synthesis. Macromolecular engineering (as discussed in the first chapter) of homo/copolymers refers to the specific tailoring of these materials for achieving an easy and reproducible synthesis that results in precise molecular characteristics, i.e. molecular weight and polydispersity, as well as specific structure and end?group choices. Precise control of these molecular characteristics will provide access to new materials that can be used for pre-targeted purposes such as biomedical applications. Among the most commonly used engineering materials are polyesters (biocompatible and biodegradable) and polyethers (biocompatible), either as homopolymers or when or copolymers with linear structures. The ability to create non-linear structures, for example stars, will open new horizons in the applications of these important polymeric materials. The second part of this thesis describes the synthesis of aliphatic polyesters, particularly polycaprolactone and polylactide, using a metal-free initiator/catalyst system. A phosphazene base (t?BuP2) was used as the catalyst for the ring-opening copolymerization of ?-aprolactone (??CL) and L,Lactide (LLA) at room temperature with a variety of protic initiators in different solvents. These studies provided important information for the design of a metal-free route toward the synthesis of polyester?based (bio) materials. The third part of the thesis describes a novel route for the one?pot synthesis of polyether-b polyester block copolymers with either a linear or a specific macromolecular architecture. Poly (styrene oxide)?b?poly(caprolactone)?b?poly(L,lactide) was prepared using this method with the goal of synthesizing poly(styrene oxide)-based materials since this

  4. Effects of iodinated contrast media on renal function in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Jacob, H.M.

    1980-01-01

    Case histories of 89 patients with definite myoloma of the years 1959 to 1974 were investigated in a retrospective study. 41 intravenous urographies were carried out in 31 of these patients. There was no correlation between deterioration of the renal function and contrast medium application. Relevant literature on the subject has been compiled. By 1979, 19 case studies and 5 general studies had been published which have been summarized in tables in the present study. Analyses of these case histories have shown that acute renal failure was often due to other causes and not to contrast medium application. If these cases are left out of account 8 cases remain in which lethal renal failure occurred after intravenous urography of myeloma patients. The diiodinated contrast media formerly used was less well tolerated than the present triiodinated contrast media. Further risk factors were dehydratation and/or abdominal compression. Both measures are no longer employed in intravenous urography. (orig./MG) [de

  5. Process for preparation of MR contrast agents

    DEFF Research Database (Denmark)

    2002-01-01

    The present invention provides a process for the preparation of an MR contrast agent, said process comprising: i) obtaining a solution in a solvent of a hydrogenatable, unsaturated substrate compound and a catalyst for the hydrogenation of said substrate compound; ii) introducing said solution...... in droplet form into a chamber containing hydrogen gas (H2) enriched in para-hydrogen (p-1H2) and/or ortho-deuterium (o-2H2) whereby to hydrogenate said substrate to form a hydrogenated imaging agent; iii) optionally subjecting said hydrogenated imaging agent to a magnetic field having a field strength below...... earth's ambient field strength; iv) optionally dissolving said imaging agent in an aqueous medium; v) optionally separating said catalyst from the solution of said imaging agent in said aqueous medium; vi) optionally separating said solvent from the solution of said imaging agent in said aqueous medium...

  6. Three-dimensional contrasted visualization of pancreas in rats using clinical MRI and CT scanners.

    Science.gov (United States)

    Yin, Ting; Coudyzer, Walter; Peeters, Ronald; Liu, Yewei; Cona, Marlein Miranda; Feng, Yuanbo; Xia, Qian; Yu, Jie; Jiang, Yansheng; Dymarkowski, Steven; Huang, Gang; Chen, Feng; Oyen, Raymond; Ni, Yicheng

    2015-01-01

    The purpose of this work was to visualize the pancreas in post-mortem rats with local contrast medium infusion by three-dimensional (3D) magnetic resonance imaging (MRI) and computed tomography (CT) using clinical imagers. A total of 16 Sprague Dawley rats of about 300 g were used for the pancreas visualization. Following the baseline imaging, a mixed contrast medium dye called GadoIodo-EB containing optimized concentrations of Gd-DOTA, iomeprol and Evens blue was infused into the distally obstructed common bile duct (CBD) for post-contrast imaging with 3.0 T MRI and 128-slice CT scanners. Images were post-processed with the MeVisLab software package. MRI findings were co-registered with CT scans and validated with histomorphology, with relative contrast ratios quantified. Without contrast enhancement, the pancreas was indiscernible. After infusion of GadoIodo-EB solution, only the pancreatic region became outstandingly visible, as shown by 3D rendering MRI and CT and proven by colored dissection and histological examinations. The measured volume of the pancreas averaged 1.12 ± 0.04 cm(3) after standardization. Relative contrast ratios were 93.28 ± 34.61% and 26.45 ± 5.29% for MRI and CT respectively. We have developed a multifunctional contrast medium dye to help clearly visualize and delineate rat pancreas in situ using clinical MRI and CT scanners. The topographic landmarks thus created with 3D demonstration may help to provide guidelines for the next in vivo pancreatic MRI research in rodents. Copyright © 2015 John Wiley & Sons, Ltd.

  7. [Comparison of diagnostic quality in hysterosalpingography between iodinated non-ionic contrast media with low and high osmolarity].

    Science.gov (United States)

    Piccotti, K; Guida, D; Carbonetti, F; Stefanetti, L; Macioce, A; Cremona, A; David, V

    Comparison of diagnostic quality in hysterosalpingography between low and high-osmolality contrast media. We performed a retrospective evaluation of two cohorts of patients who underwent HSG using contrast media with different osmolarity: the first group ,47 patients, underwent hysterosalpingography in the period September 2011-December 2012 using Iopromide 370 mg/ml; the second group, 50 patients, underwent HSG from January 2013 to October 2013 using Iomeprol 400 mg/ml. Three radiologists, in consensus reading,, reviewed the radiographs by assessing the following four parameters: opacification of the uterine cavity, uterine profiles definition, Fallopian tubes visualization, contrast media spillage into peritoneum. A score-scale from 0 to 3 was assigned for each of the mentioned parameter (0 = minimum non-diagnostic exam, 1 = sufficient examination; 2 = good quality examination; maximum 3 = high quality images). We documented a statistically significant higher quality in displaying Fallopian tubes among patients studied through high osmolarity contrast medium (Iopromide 370 mg/ml) than what obtained through lower osmolarity contrast medium (Iomeprol 400 mg/ml). The use of high osmolarity contrast medium enabled better visualization of the tubes and a greater number of diagnoses of chronic aspecific salpigintis due to the increased osmolality and viscosity of Iomeprol 400 mg/ml. There were no significant differences between the two contrast agents in the evaluation of intra-uterine pathology and in the evaluation of the tubal patency.

  8. Effects of far-ultraviolet radiation and oxygen on macromolecular synthesis and protein induction in Bacteroides fragilis BF-2

    International Nuclear Information System (INIS)

    Schumann, J.P.

    1983-11-01

    The study deals with the effects of far-UV radiation, oxygen and hydrogen peroxide on macromolecular synthesis and viability in the obligate anaerobe, Bacteroides fragilis, as well as the specific proteins induced in this organism by these different DNA damaging agents. Irradiation of Bacteroides fragilis cells with far-UV light (254 nm) under anaerobic conditions resulted in the immediate, rapid and extensive degradation of DNA which continued for 40 to 60 min after irradiation. DNA degradation after irradiation was inhibited by chloramphenicol and caffeine. RNA and protein synthesis were decreased by UV irradiation and the degree of inhibition was proportional to the UV dose. Colony formation was not affected immediately by UV irradiation and continued for a dose-dependent period prior to inhibition. The relationship between the DNA damage-induced proteins, macromolecular synthesis in damaged B. fragilis cells and the observed physiological responses and inducible repair phenomena after the different DNA damaging treatments in this anaerobe are discussed

  9. Can visco-elastic phase separation, macromolecular crowding and colloidal physics explain nuclear organisation?

    Directory of Open Access Journals (Sweden)

    Iborra Francisco J

    2007-04-01

    Full Text Available Abstract Background The cell nucleus is highly compartmentalized with well-defined domains, it is not well understood how this nuclear order is maintained. Many scientists are fascinated by the different set of structures observed in the nucleus to attribute functions to them. In order to distinguish functional compartments from non-functional aggregates, I believe is important to investigate the biophysical nature of nuclear organisation. Results The various nuclear compartments can be divided broadly as chromatin or protein and/or RNA based, and they have very different dynamic properties. The chromatin compartment displays a slow, constrained diffusional motion. On the other hand, the protein/RNA compartment is very dynamic. Physical systems with dynamical asymmetry go to viscoelastic phase separation. This phase separation phenomenon leads to the formation of a long-lived interaction network of slow components (chromatin scattered within domains rich in fast components (protein/RNA. Moreover, the nucleus is packed with macromolecules in the order of 300 mg/ml. This high concentration of macromolecules produces volume exclusion effects that enhance attractive interactions between macromolecules, known as macromolecular crowding, which favours the formation of compartments. In this paper I hypothesise that nuclear compartmentalization can be explained by viscoelastic phase separation of the dynamically different nuclear components, in combination with macromolecular crowding and the properties of colloidal particles. Conclusion I demonstrate that nuclear structure can satisfy the predictions of this hypothesis. I discuss the functional implications of this phenomenon.

  10. Glycogen-graft-poly(2-alkyl-2-oxazolines) - the new versatile biopolymer-based thermoresponsive macromolecular toolbox

    Czech Academy of Sciences Publication Activity Database

    Pospíšilová, Aneta; Filippov, Sergey K.; Bogomolova, Anna; Turner, S.; Sedláček, Ondřej; Matushkin, Nikolai; Černochová, Zulfiya; Štěpánek, Petr; Hrubý, Martin

    2014-01-01

    Roč. 4, č. 106 (2014), s. 61580-61588 ISSN 2046-2069 R&D Projects: GA ČR GA13-08336S; GA MŠk(CZ) LH14079 Grant - others:AV ČR(CZ) M200501201; AV ČR(CZ) ASCR/CONICET 2012CZ006 Program:M Institutional support: RVO:61389013 Keywords : glycogen * poly(2-alkyl-2-oxazoline) * hybrid copolymer Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.840, year: 2014

  11. Do shorter wavelengths improve contrast in optical mammography?

    International Nuclear Information System (INIS)

    Taroni, P; Pifferi, A; Torricelli, A; Spinelli, L; Danesini, G M; Cubeddu, R

    2004-01-01

    The detection of tumours with time-resolved transmittance imaging relies essentially on blood absorption. Previous theoretical and phantom studies have shown that both contrast and spatial resolution of optical images are affected by the optical properties of the background medium, and high absorption and scattering are generally beneficial. Based on these observations, wavelengths shorter than presently used (680-780 nm) could be profitable for optical mammography. A study was thus performed analysing time-resolved transmittance images at 637, 656, 683 and 785 nm obtained from 26 patients bearing 16 tumours and 15 cysts. The optical contrast proved to increase upon decreasing wavelengths for the detection of cancers in late-gated intensity images, with higher gain in contrast for lesions of smaller size (<1.5 cm diameter). For cysts either a progressive increase or decrease in contrast with wavelength was observed in scattering images

  12. Rapid MR measurements of contrast medium dilution kinetics (gadolinium-DTPA) in a flow phantom

    International Nuclear Information System (INIS)

    Boeck, J.C.; Sander, B.; Frank, J.; Schoerner, W.

    1991-01-01

    We studied first-pass MRI-contrast dilution to compute flow and volume of distribution in a realistic flow phantom. Pulsatile flow was provided by a one-chamber artificial heart. Physiological stroke volume, rate, pressure, and flow were adjustable. An elastic tube with dimensions similar to that of the human aorta was imaged at a rate of 2.4 Hz. After contrast injection, an initial increase in signal intensity was followed by a decrease. Signal-intensity-time plots demonstrated slightly skewed curves as expected from dispersion theory. After calibration at different gadolinium-DTPA concentrations, signal intensities were converted into true gadolinium concentrations, and flow was calculated from the concentration-time curves. Flow was varied between 2.5 and 10.0 l/min and a significant correlation was found between the MRI-estimate and true flow. Volume of distribution between injection and detection site was reliably estimated. This study demonstrates rapid 2-D imaging of a paramagnetic contrast bolus in a realistic flow phantom. Reliable estimates of flow and volume are obtained. (orig.) [de

  13. Shoulder arthrography: comparison of morbidity after use of various contrast media

    International Nuclear Information System (INIS)

    Hall, F.M.; Goldberg, R.P.; Wyshak, G.; Kilcoyne, R.F.

    1985-01-01

    This prospective study compares immediate and delayed patient discomfort in 177 patients following shoulder arthrography using intraarticular combinations of metrizamide, meglumine/sodium diatrizoate, meglumine diatrizoate, lidocaine, epinephrine, and air. Patients receiving conventional ionic monomeric positive contrast media had a 60% (90/150) incidence of moderate or severe delayed exacerbation of their baseline symptoms; only 14% (3/21) of patients receiving metrizamide, a nonionic contrast medium had similar levels of postprocedural discomfort. Morbidity was somewhat diminished with the use of double-contrast (45%, 34/75) rather than single-contrast (75%, 56/75) examinations, and with avoidance of sodium-containing contrast agents or epinephrine. Nonionic or monovalent polymeric contrast media, despite their present high cost, may be the agents of choice if single-contrast arthrography is performed in joints associated with a high incidence of postprocedural pain

  14. Contrast-enhanced magnetic resonance imaging of tumours of the central nervous systems: a clinical review

    International Nuclear Information System (INIS)

    Graif, M.; Steiner, R.E.

    1986-01-01

    The clinical application of the intravascular paramagnetic contrast agent gadolinium-DTPA for magnetic resonance imaging (MRI) imaging of tumours of the central nervous system (CNS) has been assessed over the past 3 years. Various patterns of contrast enhancement were observed, and situations in MRI where the administration of contrast medium may be useful have been defined. These include lesions which are isointense with normal brain matter, the separation of tumour from surrounding oedema, evaluation of the degree of blood-brain barrier breakdown, delineation of tumours obscured by overlying calcification on computed tomography (CT) and in the investigation of lesions in anatomical areas where CT has known limitations (brain, stem, cervical spine). Changes in relaxation times in normal and abnormal tissues following contrast medium, toxicity and dosage of gadolinium-DTPA, and MRI pulse sequence techniques are reviewed. (author)

  15. THESEUS: maximum likelihood superpositioning and analysis of macromolecular structures.

    Science.gov (United States)

    Theobald, Douglas L; Wuttke, Deborah S

    2006-09-01

    THESEUS is a command line program for performing maximum likelihood (ML) superpositions and analysis of macromolecular structures. While conventional superpositioning methods use ordinary least-squares (LS) as the optimization criterion, ML superpositions provide substantially improved accuracy by down-weighting variable structural regions and by correcting for correlations among atoms. ML superpositioning is robust and insensitive to the specific atoms included in the analysis, and thus it does not require subjective pruning of selected variable atomic coordinates. Output includes both likelihood-based and frequentist statistics for accurate evaluation of the adequacy of a superposition and for reliable analysis of structural similarities and differences. THESEUS performs principal components analysis for analyzing the complex correlations found among atoms within a structural ensemble. ANSI C source code and selected binaries for various computing platforms are available under the GNU open source license from http://monkshood.colorado.edu/theseus/ or http://www.theseus3d.org.

  16. Macromolecular organization of xyloglucan and cellulose in pea epicotyls

    International Nuclear Information System (INIS)

    Hayashi, T.; Maclachlan, G.

    1984-01-01

    Xyloglucan is known to occur widely in the primary cell walls of higher plants. This polysaccharide in most dicots possesses a cellulose-like main chain with three of every four consecutive residues substituted with xylose and minor addition of other sugars. Xyloglucan and cellulose metabolism is regulated by different processes; since different enzyme systems are probably required for the synthesis of their 1,4-β-linkages. A macromolecular complex composed of xyloglucan and cellulose only was obtained from elongating regions of etiolated pea stems. It was examined by light microscopy using iodine staining, by radioautography after labeling with [ 3 H]fructose, by fluorescence microscopy using a fluorescein-lectin (fructose-binding) as probe, and by electron microscopy after shadowing. The techniques all demonstrated that the macromolecule was present in files of cell shapes, referred to here as cell-wall ghosts, in which xyloglucan was localized both on and between the cellulose microfibrils

  17. Iodinated contrast media and patients with high-risk kidneys. Aiming at rational prevention

    International Nuclear Information System (INIS)

    Fontaine, B.; Frouge, C.; Gagey, N.

    1994-01-01

    Acute renal failure induced by iodinated contrast media (CM) accounts for about 10% of all hospital cases of renal failure, especially in azotemic patients. The specific anatomy and physiology of the inner medulla renalis render it particularly sensitive to even a moderate reduction in blood supply. Renal function will be estimated by measuring serum creatinine levels, before and within 72 hours after administration of the iodinated contrast medium. Hypovolaemia, diabetes mellitus-induced microangiopathy, nephrotoxic drugs and especially dehydratation may provoke renal accidents. Proper hydration, choosing a low osmolality medium and adequately spacing exposures to CM are elementary measures to be adopted to prevent renal failure. (authors)

  18. Effects of radiographic contrast media on the serum complement system

    International Nuclear Information System (INIS)

    Tirone, P.; Boldrini, E.

    1983-01-01

    The authors explored the activation of the complement system produced by a nonionic organic iodine compound, namely iopamidol, which is proposed as a contrast medium for radiographic examination by intravenous and intra-arterial injection. The study was conducted in vitro versus established ionic contrasts (diatrizoate, iothalamate, acetrizoate) and a nonionic compound (metrizamide). The adopted experimental model was the immunohemolytic detector system, in which the immune complex consisted of goat erythrocytes sensitized with the corresponding antibody (hemolysin), and complement (C') was supplied by guinea pig serum. All the products caused complement activation. The results show that nonionic contrast media produce less activation of the complement system than the traditional ionic contrast. Thus the use of nonionic contrast for radiological procedures necessitating the introduction of contrast material into the blood compartment would imply a reduced risk of anaphylactoid reactions. (orig.)

  19. AR-NE3A, a New Macromolecular Crystallography Beamline for Pharmaceutical Applications at the Photon Factory

    International Nuclear Information System (INIS)

    Yamada, Yusuke; Hiraki, Masahiko; Sasajima, Kumiko; Matsugaki, Naohiro; Igarashi, Noriyuki; Kikuchi, Takashi; Mori, Takeharu; Toyoshima, Akio; Kishimoto, Shunji; Wakatsuki, Soichi; Amano, Yasushi; Warizaya, Masaichi; Sakashita, Hitoshi

    2010-01-01

    Recent advances in high-throughput techniques for macromolecular crystallography have highlighted the importance of structure-based drug design (SBDD), and the demand for synchrotron use by pharmaceutical researchers has increased. Thus, in collaboration with Astellas Pharma Inc., we have constructed a new high-throughput macromolecular crystallography beamline, AR-NE3A, which is dedicated to SBDD. At AR-NE3A, a photon flux up to three times higher than those at existing high-throughput beams at the Photon Factory, AR-NW12A and BL-5A, can be realized at the same sample positions. Installed in the experimental hutch are a high-precision diffractometer, fast-readout, high-gain CCD detector, and sample exchange robot capable of handling more than two hundred cryo-cooled samples stored in a Dewar. To facilitate high-throughput data collection required for pharmaceutical research, fully automated data collection and processing systems have been developed. Thus, sample exchange, centering, data collection, and data processing are automatically carried out based on the user's pre-defined schedule. Although Astellas Pharma Inc. has a priority access to AR-NE3A, the remaining beam time is allocated to general academic and other industrial users.

  20. Organ specific acute toxicity of the carcinogen trans-4-acetylaminostilbene is not correlated with macromolecular binding.

    Science.gov (United States)

    Pfeifer, A; Neumann, H G

    1986-09-01

    trans-4-Acetylaminostilbene (trans-AAS) is acutely toxic in rats and lesions are produced specifically in the glandular stomach. Toxicity is slightly increased by pretreating the animals with phenobarbital (PB) and is completely prevented by pretreatment with methylcholanthrene (MC). The prostaglandin inhibitors, indomethacin and acetyl salicylic acid, do not reduce toxicity. The high efficiency of MC suggested that toxicity is caused by reactive metabolites. trans-[3H]-AAS was administered orally to untreated and to PB- or MC-pretreated female Wistar rats and target doses in different tissues were measured by means of covalent binding to proteins, RNA and DNA. Macromolecular binding in the target tissue of poisoned animals was significantly lower than in liver and kidney and comparable to other non-target tissues. Pretreatment with MC lowered macromolecular binding in all extrahepatic tissues but not in liver. These findings are not in line with tissue specific metabolic activation. The only unique property of the target tissue, glandular stomach, that we observed was a particular affinity for the systemically available parent compound. In the early phase of poisoning, tissue concentrations were exceedingly high and the stomach function was impaired.

  1. Independent component analysis of dynamic contrast-enhanced computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Koh, T S [School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Ave, Singapore 639798 (Singapore); Yang, X [School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Ave, Singapore 639798 (Singapore); Bisdas, S [Department of Diagnostic and Interventional Radiology, Johann Wolfgang Goethe University Hospital, Theodor-Stern-Kai 7, D-60590 Frankfurt (Germany); Lim, C C T [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore)

    2006-10-07

    Independent component analysis (ICA) was applied on dynamic contrast-enhanced computed tomography images of cerebral tumours to extract spatial component maps of the underlying vascular structures, which correspond to different haemodynamic phases as depicted by the passage of the contrast medium. The locations of arteries, veins and tumours can be separately identified on these spatial component maps. As the contrast enhancement behaviour of the cerebral tumour differs from the normal tissues, ICA yields a tumour component map that reveals the location and extent of the tumour. Tumour outlines can be generated using the tumour component maps, with relatively simple segmentation methods. (note)

  2. Fully automated data collection and processing system on macromolecular crystallography beamlines at the PF

    International Nuclear Information System (INIS)

    Yamada, Yusuke; Hiraki, Masahiko; Matsugaki, Naohiro; Chavas, Leonard M.G.; Igarashi, Noriyuki; Wakatsuki, Soichi

    2012-01-01

    Fully automated data collection and processing system has been developed on macromolecular crystallography beamlines at the Photon Factory. In this system, the sample exchange, centering and data collection are sequentially performed for all samples stored in the sample exchange system at a beamline without any manual operations. Data processing of collected data sets is also performed automatically. These results are stored into the database system, and users can monitor the progress and results of automated experiment via a Web browser. (author)

  3. Contrast media for radiological examination in gastrointestinal tract leakage

    NARCIS (Netherlands)

    A.Z. Ginai (Abida)

    1987-01-01

    textabstractThe aim of this investigation has been to find a safe and suitable contrast medium for radiological evaluation of the gastrointestinal tract in cases where leakage outside the GIT can be suspected. Leakage outside the gastro-intestinal tract lumen can occur in many ways eg.,

  4. Beacon-S TM: Non-uniform attenuation correction for SPECT imaging. The new medium-energy transmission device for AXIS and IRIX

    International Nuclear Information System (INIS)

    Daniel Gagnon, D.

    1999-01-01

    The paper presents new medium-energy transmission device for SPECT imaging. Beacon-S includes a 356-keV medium energy 133 Ba source with a 10.54-year half-life. Beacon-S provide high-resolution and high-contrast transmission scans. The higher energy of the gamma substantially improves the transmission contrast for larger patients by virtue of better penetration through the body

  5. Development of an online UV–visible microspectrophotometer for a macromolecular crystallography beamline

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Nobutaka, E-mail: nobutaka.shimizu@kek.jp [SPring-8/JASRI, 1-1-1 Koto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Shimizu, Tetsuya [RIKEN SPring-8 Center, 1-1-1 Koto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Baba, Seiki; Hasegawa, Kazuya [SPring-8/JASRI, 1-1-1 Koto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Yamamoto, Masaki [RIKEN SPring-8 Center, 1-1-1 Koto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Kumasaka, Takashi [SPring-8/JASRI, 1-1-1 Koto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan)

    2013-11-01

    An online UV–visible microspectrophotometer has been developed for the macromolecular crystallography beamline at SPring-8. Details of this spectrophotometer are reported. Measurement of the UV–visible absorption spectrum is a convenient technique for detecting chemical changes of proteins, and it is therefore useful to combine spectroscopy and diffraction studies. An online microspectrophotometer for the UV–visible region was developed and installed on the macromolecular crystallography beamline, BL38B1, at SPring-8. This spectrophotometer is equipped with a difference dispersive double monochromator, a mercury–xenon lamp as the light source, and a photomultiplier as the detector. The optical path is mostly constructed using mirrors, in order to obtain high brightness in the UV region, and the confocal optics are assembled using a cross-slit diaphragm like an iris to eliminate stray light. This system can measure optical densities up to a maximum of 4.0. To study the effect of radiation damage, preliminary measurements of glucose isomerase and thaumatin crystals were conducted in the UV region. Spectral changes dependent on X-ray dose were observed at around 280 nm, suggesting that structural changes involving Trp or Tyr residues occurred in the protein crystal. In the case of the thaumatin crystal, a broad peak around 400 nm was also generated after X-ray irradiation, suggesting the cleavage of a disulfide bond. Dose-dependent spectral changes were also observed in cryo-solutions alone, and these changes differed with the composition of the cryo-solution. These responses in the UV region are informative regarding the state of the sample; consequently, this device might be useful for X-ray crystallography.

  6. A facile metal-free "grafting-from" route from acrylamide-based substrate toward complex macromolecular combs

    KAUST Repository

    Zhao, Junpeng

    2013-01-01

    High-molecular-weight poly(N,N-dimethylacrylamide-co-acrylamide) was used as a model functional substrate to investigate phosphazene base (t-BuP 4)-promoted metal-free anionic graft polymerization utilizing primary amide moieties as initiating sites. The (co)polymerization of epoxides was proven to be effective, leading to macromolecular combs with side chains being single- or double-graft homopolymer, block copolymer and statistical copolymer. © 2013 The Royal Society of Chemistry.

  7. Macromolecular pHPMA-based nanoparticles with cholesterol for solid tumor targeting: behavior in HSA protein environment

    Czech Academy of Sciences Publication Activity Database

    Zhang, X.; Niebuur, B.-J.; Chytil, Petr; Etrych, Tomáš; Filippov, Sergey K.; Kikhney, A.; Wieland, D. C. F.; Svergun, D. I.; Papadakis, C. M.

    2018-01-01

    Roč. 19, č. 2 (2018), s. 470-480 ISSN 1525-7797 R&D Projects: GA ČR(CZ) GC15-10527J; GA MZd(CZ) NV16-28594A; GA MŠk(CZ) LO1507 Institutional support: RVO:61389013 Keywords : polymer carriers * N-(2-hydroxypropyl)methacrylamide * tumor targeting Subject RIV: CD - Macromolecular Chemistry OBOR OECD: Polymer science Impact factor: 5.246, year: 2016

  8. High Relaxivity Gadolinium Hydroxypyridonate-Viral Capsid Conjugates: Nano-sized MRI Contrast Agents

    Energy Technology Data Exchange (ETDEWEB)

    Meux, Susan C.; Datta, Ankona; Hooker, Jacob M.; Botta, Mauro; Francis, Matthew B.; Aime, Silvio; Raymond, Kenneth N.

    2007-08-29

    High relaxivity macromolecular contrast agents based on the conjugation of gadolinium chelates to the interior and exterior surfaces of MS2 viral capsids are assessed. The proton nuclear magnetic relaxation dispersion (NMRD) profiles of the conjugates show up to a five-fold increase in relaxivity, leading to a peak relaxivity (per Gd{sup 3+} ion) of 41.6 mM{sup -1}s{sup -1} at 30 MHz for the internally modified capsids. Modification of the exterior was achieved through conjugation to flexible lysines, while internal modification was accomplished by conjugation to relatively rigid tyrosines. Higher relaxivities were obtained for the internally modified capsids, showing that (1) there is facile diffusion of water to the interior of capsids and (2) the rigidity of the linker attaching the complex to the macromolecule is important for obtaining high relaxivity enhancements. The viral capsid conjugated gadolinium hydroxypyridonate complexes appear to possess two inner-sphere water molecules (q = 2) and the NMRD fittings highlight the differences in the local motion for the internal ({tau}{sub RI} = 440 ps) and external ({tau}{sub RI} = 310 ps) conjugates. These results indicate that there are significant advantages of using the internal surface of the capsids for contrast agent attachment, leaving the exterior surface available for the installation of tissue targeting groups.

  9. The limit values for brightness and contrast adjustment in digital panoramic radiography

    Science.gov (United States)

    Zahra, A. T.; Syahraini, S. I.; Kiswanjaya, B.; Ustriyana, P.

    2017-08-01

    There is an overall lack of studies about digital panoramic radiography. The application of image enhancement techniques is still being done based on the operator’s preferences, since there is no objective limitation. The aim is to evaluate the limit values of the brightness and contrast adjustment in digital panoramic radiography. Digital panoramic radiographs were divided into three groups (dark, medium, and light), and the contrast and brightness adjustments were done using Digora for Windows. The static evaluations were done using three criteria: 1 if the image had lower quality, 2 if there was no difference and 3 if the image had better quality. The radiographic changes differed in each group depending on the initial imaging conditions. The brightness adjustment limit values in the dark and medium groups were -10 and +20, respectively, and -20 and +10 in the light group. The contrast adjustment limit values in all of the groups were -10 and +10.

  10. [Extravasation of contrast media at the puncture site: Strategies for managment].

    Science.gov (United States)

    Pacheco Compaña, F J; Gago Vidal, B; Méndez Díaz, C

    2014-01-01

    The incidence of contrast medium extravasation at the venipuncture site has increased with the generalized use of automatic injectors. Most extravasations only cause slight edema and erythema. Nevertheless, in some cases extravasation can result in severe skin lesions or even in compartment syndrome. Lesions caused by extravasation usually resolve spontaneously with conservative treatment. Although the complications of extravasation are well known, institutional protocols are normally lacking and the criteria for taking action and the type of treatment, whether based on the literature or personal preferences, tend to vary. In this article, we review the incidence, risk factors, clinical manifestations, and options for preventing and treating contrast medium extravasation in soft tissues. Finally, we present the protocol we use to manage extravasation at our hospital. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.

  11. Activation of platelets by low-osmolar contrast media: differential effects of ionic and nonionic agents

    NARCIS (Netherlands)

    Hardeman, M. R.; Konijnenberg, A.; Sturk, A.; Reekers, J. A.

    1994-01-01

    To determine the effects of an ionic low-osmolar contrast medium (ioxaglate) and two nonionic low-osmolar contrast media (iohexol and iopamidol) on human platelet activation in vitro. Flow cytometry analysis subsequent to reaction with fluorescence-labeled monoclonal antibodies was used to detect

  12. Single and double contrast arthrography in lesions of the glenohumeral joint

    International Nuclear Information System (INIS)

    Ahovuo, J.

    1984-01-01

    One hundred and forty-five arthrograms from single and double contrast arthrography were compared with respect to their accuracy in revealing lesions of the glenohumeral joint. Total and partial rotator cuff tears were accurately delineated by both single and double contrast arthrography. The size of the tear did not correlate with surgical findings with either technique. The volume of the injected contrast medium was larger in full-thickness rotator cuff tears than in normal arthrograms (p 2 test). No difference in filling frequency of the sheath could be observed between single and double contrast arthrography. This study did not reveal any major advantages of double contrast arthrography over single contrast examinations in lesions of the rotator cuff and those of the tendon of the long head of the biceps brachii. (orig.)

  13. Probing the mechanisms of drug release from amorphous solid dispersions in medium-soluble and medium-insoluble carriers.

    Science.gov (United States)

    Sun, Dajun D; Lee, Ping I

    2015-08-10

    The objective of the current study is to mechanistically differentiate the dissolution and supersaturation behaviors of amorphous drugs from amorphous solid dispersions (ASDs) based on medium-soluble versus medium-insoluble carriers under nonsink dissolution conditions through a direct head-to-head comparison. ASDs of indomethacin (IND) were prepared in several polymers which exhibit different solubility behaviors in acidic (pH1.2) and basic (pH7.4) dissolution media. The selected polymers range from water-soluble (e.g., PVP and Soluplus) and water-insoluble (e.g., ethylcellulose and Eudragit RL PO) to those only soluble in an acidic or basic dissolution medium (e.g., Eudragit E100, Eudragit L100, and HPMCAS). At 20wt.% drug loading, DSC and powder XRD analysis confirmed that the majority of incorporated IND was present in an amorphous state. Our nonsink dissolution results confirm that whether the carrier matrix is medium soluble determines the release mechanism of amorphous drugs from ASD systems which has a direct impact on the rate of supersaturation generation, thus in turn affecting the evolution of supersaturation in amorphous systems. For example, under nonsink dissolution conditions, the release of amorphous IND from medium-soluble carriers is governed by a dissolution-controlled mechanism leading to an initial surge of supersaturation followed by a sharp decline in drug concentration due to rapid nucleation and crystallization. In contrast, the dissolution of IND ASD from medium-insoluble carriers is more gradual as drug release is regulated by a diffusion-controlled mechanism by which drug supersaturation is built up gradually and sustained over an extended period of time without any apparent decline. Since several tested carrier polymers can be switched from soluble to insoluble by simply changing the pH of the dissolution medium, the results obtained here provide unequivocal evidence of the proposed transition of kinetic solubility profiles from the

  14. Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography

    International Nuclear Information System (INIS)

    Seifarth, Harald; Puesken, Michael; Wienbeck, Susanne; Wessling, Johannes; Maintz, David; Heindel, Walter; Juergens, Kai-Uwe; Kalafut, John F.

    2009-01-01

    The aim of this study was to determine whether individually tailored protocols for the injection of contrast medium (CM) result in higher and more homogeneous vascular attenuation throughout the coronary arteries at coronary CT angiography compared with conventional injection protocols using fixed injection parameters. Of 120 patients included in the study, 80 patients were randomized into two groups. Group 1 received 80 mL of CM at 6 mL/s. For group 2 injection parameters were individually adjusted to patient weight, the duration of CT data acquisition, and attenuation parameters following a test bolus. In the control group (group 3) the volume of CM was adjusted to the duration of CT data acquisition and injected at 5 mL/s. Attenuation was measured in the proximal, middle, and distal right coronary artery (RCA), in the proximal and middle left anterior descending artery (LAD), and in cranial and caudal sections of both ventricles. Patient parameters, scan delay, and scan duration did not differ significantly between the groups. Mean CM volume was 82.5 mL (flow rate 5.1 mL/s) in group 2 and 73.5 mL in group 3. Attenuation in both RCA and LAD was significantly higher for group 2 vs. group 3 (RCA: 414.9(±49.9)-396.1(±52.1) HU vs. 366.0(±64.3)-341.6(±72.5) HU; LAD: 398.9(±48.6)-364.6(±44.6) HU vs. 356.3(±69.5)-323.0(±67.2) HU). For group 1 vs. group 2 only attenuation in the distal RCA differed significantly: 396.1(±52.1) vs. 370.7(±70.5) HU. Individually tailored CM injection protocols yield higher attenuation, especially in the distal segments of the coronary vessels, compared with injection protocols using fixed injection parameters. (orig.)

  15. Macromolecular crowding gives rise to microviscosity, anomalous diffusion and accelerated actin polymerization.

    Science.gov (United States)

    Rashid, Rafi; Chee, Stella Min Ling; Raghunath, Michael; Wohland, Thorsten

    2015-04-30

    Macromolecular crowding (MMC) has been used in various in vitro experimental systems to mimic in vivo physiology. This is because the crowded cytoplasm of cells contains many different types of solutes dissolved in an aqueous medium. MMC in the extracellular microenvironment is involved in maintaining stem cells in their undifferentiated state (niche) as well as in aiding their differentiation after they have travelled to new locations outside the niche. MMC at physiologically relevant fractional volume occupancies (FVOs) significantly enhances the adipogenic differentiation of human bone marrow-derived mesenchymal stem cells during chemically induced adipogenesis. The mechanism by which MMC produces this enhancement is not entirely known. In the context of extracellular collagen deposition, we have recently reported the importance of optimizing the FVO while minimizing the bulk viscosity. Two opposing properties will determine the net rate of a biochemical reaction: the negative effect of bulk viscosity and the positive effect of the excluded volume, the latter being expressed by the FVO. In this study we have looked more closely at the effect of viscosity on reaction rates. We have used fluorimetry to measure the rate of actin polymerization and fluorescence correlation spectroscopy (FCS) to measure diffusion of various probes in solutions containing the crowder Ficoll at physiological concentrations. Similar to its effect on collagen, Ficoll enhanced the actin polymerization rate despite increasing the bulk viscosity. Our FCS measurements reveal a relatively minor component of anomalous diffusion. In addition, our measurements do suggest that microviscosity becomes relevant in a crowded environment. We ruled out bulk viscosity as a cause of the rate enhancement by performing the actin polymerization assay in glycerol. These opposite effects of Ficoll and glycerol led us to conclude that microviscosity becomes relevant at the length scale of the reacting

  16. Macromolecular crowding gives rise to microviscosity, anomalous diffusion and accelerated actin polymerization

    Science.gov (United States)

    Rashid, Rafi; Chee, Stella Min Ling; Raghunath, Michael; Wohland, Thorsten

    2015-05-01

    Macromolecular crowding (MMC) has been used in various in vitro experimental systems to mimic in vivo physiology. This is because the crowded cytoplasm of cells contains many different types of solutes dissolved in an aqueous medium. MMC in the extracellular microenvironment is involved in maintaining stem cells in their undifferentiated state (niche) as well as in aiding their differentiation after they have travelled to new locations outside the niche. MMC at physiologically relevant fractional volume occupancies (FVOs) significantly enhances the adipogenic differentiation of human bone marrow-derived mesenchymal stem cells during chemically induced adipogenesis. The mechanism by which MMC produces this enhancement is not entirely known. In the context of extracellular collagen deposition, we have recently reported the importance of optimizing the FVO while minimizing the bulk viscosity. Two opposing properties will determine the net rate of a biochemical reaction: the negative effect of bulk viscosity and the positive effect of the excluded volume, the latter being expressed by the FVO. In this study we have looked more closely at the effect of viscosity on reaction rates. We have used fluorimetry to measure the rate of actin polymerization and fluorescence correlation spectroscopy (FCS) to measure diffusion of various probes in solutions containing the crowder Ficoll at physiological concentrations. Similar to its effect on collagen, Ficoll enhanced the actin polymerization rate despite increasing the bulk viscosity. Our FCS measurements reveal a relatively minor component of anomalous diffusion. In addition, our measurements do suggest that microviscosity becomes relevant in a crowded environment. We ruled out bulk viscosity as a cause of the rate enhancement by performing the actin polymerization assay in glycerol. These opposite effects of Ficoll and glycerol led us to conclude that microviscosity becomes relevant at the length scale of the reacting

  17. Extracting trends from two decades of microgravity macromolecular crystallization history.

    Science.gov (United States)

    Judge, Russell A; Snell, Edward H; van der Woerd, Mark J

    2005-06-01

    Since the 1980s hundreds of macromolecular crystal growth experiments have been performed in the reduced acceleration environment of an orbiting spacecraft. Significant enhancements in structural knowledge have resulted from X-ray diffraction of the crystals grown. Similarly, many samples have shown no improvement or degradation in comparison to those grown on the ground. A complex series of interrelated factors affect these experiments and by building a comprehensive archive of the results it was aimed to identify factors that result in success and those that result in failure. Specifically, it was found that dedicated microgravity missions increase the chance of success when compared with those where crystallization took place as a parasitic aspect of the mission. It was also found that the chance of success could not be predicted based on any discernible property of the macromolecule available to us.

  18. Technique of application of contrast media in computed tomography of the heart

    International Nuclear Information System (INIS)

    Heuser, L.; Friedmann, G.

    1982-01-01

    Cardiac imaging by means of CT requires administration of intravenous contrast medium which can be applied by infusion or by rapid bolus injection. Contrast infusion is easier in performance and yields opacification of all cardiac cavities. Using bolus technique selective enhancement of cardiac chambers can be obtained which provides increased image quality and better resolution of cardiac structures. Both techniques are described and the results of 221 examinations are analysed with special respect to image quality, technical amount and contrast media side effects. (orig.) [de

  19. Contrastive analysis in mother tongue teaching in Sweden – teacher’sperceptions and practices

    OpenAIRE

    Reis, Marina

    2017-01-01

    This study is about contrastive analysis in mother tongue teaching in Sweden. Contrastive analysis between mother tongue and Swedish is part of the Swedish syllabus for the school subject mother tongue and is therefore a pertinent subject to be investigated. The study analyzes how five mother tongue teachers in a medium-sized Swedish city work with contrastive analysis in their classes and how they evaluate the importance of this content in mother tongue teaching. The question concerning the ...

  20. A new paradigm for macromolecular crystallography beamlines derived from high-pressure methodology and results

    Energy Technology Data Exchange (ETDEWEB)

    Fourme, Roger, E-mail: roger.fourme@synchrotron-soleil.fr [Synchrotron SOLEIL, BP 48, Saint Aubin, 91192 Gif-sur-Yvette (France); Girard, Eric [IBS (UMR 5075 CEA-CNRS-UJF-PSB), 41 rue Jules Horowitz, 38027 Grenoble Cedex (France); Dhaussy, Anne-Claire [CRISMAT, ENSICAEN, 6 Boulevard du Maréchal Juin, 14000 Caen (France); Medjoubi, Kadda [Synchrotron SOLEIL, BP 48, Saint Aubin, 91192 Gif-sur-Yvette (France); Prangé, Thierry [LCRB (UMR 8015 CNRS), Université Paris Descartes, Faculté de Pharmacie, 4 avenue de l’Observatoire, 75270 Paris (France); Ascone, Isabella [ENSCP (UMR CNRS 7223), 11 rue Pierre et Marie Curie, 75231 Paris Cedex 05 (France); Mezouar, Mohamed [ESRF, BP 220, 38043 Grenoble (France); Kahn, Richard [IBS (UMR 5075 CEA-CNRS-UJF-PSB), 41 rue Jules Horowitz, 38027 Grenoble Cedex (France)

    2011-01-01

    Macromolecular crystallography at high pressure (HPMX) is a mature technique. Shorter X-ray wavelengths increase data collection efficiency on cryocooled crystals. Extending applications and exploiting spin-off of HPMX will require dedicated synchrotron radiation beamlines based on a new paradigm. Biological structures can now be investigated at high resolution by high-pressure X-ray macromolecular crystallography (HPMX). The number of HPMX studies is growing, with applications to polynucleotides, monomeric and multimeric proteins, complex assemblies and even a virus capsid. Investigations of the effects of pressure perturbation have encompassed elastic compression of the native state, study of proteins from extremophiles and trapping of higher-energy conformers that are often of biological interest; measurements of the compressibility of crystals and macromolecules were also performed. HPMX results were an incentive to investigate short and ultra-short wavelengths for standard biocrystallography. On cryocooled lysozyme crystals it was found that the data collection efficiency using 33 keV photons is increased with respect to 18 keV photons. This conclusion was extended from 33 keV down to 6.5 keV by exploiting previously published data. To be fully exploited, the potential of higher-energy photons requires detectors with a good efficiency. Accordingly, a new paradigm for MX beamlines was suggested, using conventional short and ultra-short wavelengths, aiming at the collection of very high accuracy data on crystals under standard conditions or under high pressure. The main elements of such beamlines are outlined.

  1. MRI contrast agent concentration and tumor interstitial fluid pressure.

    Science.gov (United States)

    Liu, L J; Schlesinger, M

    2016-10-07

    The present work describes the relationship between tumor interstitial fluid pressure (TIFP) and the concentration of contrast agent for dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). We predict the spatial distribution of TIFP based on that of contrast agent concentration. We also discuss the cases for estimating tumor interstitial volume fraction (void fraction or porosity of porous medium), ve, and contrast volume transfer constant, K(trans), by measuring the ratio of contrast agent concentration in tissue to that in plasma. A linear fluid velocity distribution may reflect a quadratic function of TIFP distribution and lead to a practical method for TIFP estimation. To calculate TIFP, the parameters or variables should preferably be measured along the direction of the linear fluid velocity (this is in the same direction as the gray value distribution of the image, which is also linear). This method may simplify the calculation for estimating TIFP. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  2. Diagnostic accuracy of surface coil MRI in assessing cartilaginous invasion in laryngeal tumours. Do we need contrast-agent administration?

    International Nuclear Information System (INIS)

    Preda, Lorenzo; Conte, Giorgio; Bonello, Luke; Giannitto, Caterina; Tagliabue, Elena; Raimondi, Sara; Ansarin, Mohssen; De Benedetto, Luigi; Cattaneo, Augusto; Maffini, Fausto; Bellomi, Massimo

    2017-01-01

    To assess the diagnostic accuracy of MRI performed using surface coils, with and without contrast medium, in predicting thyroid and cricoid cartilage infiltration in laryngeal tumours, and to investigate whether the radiologist's experience influences diagnostic accuracy. We retrospectively enrolled patients with biopsy-proven laryngeal cancer who had undergone preoperative staging MRI and open surgery. Two radiologists with different experience (senior vs. junior) reviewed the MR images without (session A1) and with contrast medium (session A2) separately. We calculated the accuracy of MRI with and without contrast medium in detecting infiltration of the thyroid and cricoid cartilages. Interobserver agreement was calculated by Cohen's Kappa (k). Forty-two patients were enrolled, for a total of 62 cartilages. In session A1 the senior and junior radiologists showed an accuracy of 85% and 71%, respectively, with k = 0.53 (0.33-0.72). In session A2 the senior and junior radiologists showed an accuracy of 84% and 77%, respectively, with k = 0.68 (0.49-0.86). Staging of laryngeal tumours with surface coil MRI showed good diagnostic accuracy in assessing cartilaginous infiltration. We observed similar values of diagnostic accuracy for the analysis performed with and without contrast medium for the senior radiologist. (orig.)

  3. Diagnostic accuracy of surface coil MRI in assessing cartilaginous invasion in laryngeal tumours. Do we need contrast-agent administration?

    Energy Technology Data Exchange (ETDEWEB)

    Preda, Lorenzo [Universita degli Studi di Pavia, Department of Clinical-Surgical Diagnostic and Pediatric Sciences, Pavia (Italy); Division of Radiology, National Center of Oncological Hadrontherapy (CNAO Foundation), Pavia (Italy); Conte, Giorgio [Universita degli Studi di Milano, Postgraduation School in Radiodiagnostics, Milan (Italy); Bonello, Luke [Division of Radiology, Poliambulanza Hospital, Brescia (Italy); Giannitto, Caterina [European Institute of Oncology, Division of Radiology, Milan (Italy); Tagliabue, Elena; Raimondi, Sara [European Institute of Oncology, Division of Epidemiology and Biostatistics, Milan (Italy); Ansarin, Mohssen; De Benedetto, Luigi; Cattaneo, Augusto [European Institute of Oncology, Division of Head and Neck Surgery, Milan (Italy); Maffini, Fausto [European Institute of Oncology, Division of Pathology, Milan (Italy); Bellomi, Massimo [European Institute of Oncology, Division of Radiology, Milan (Italy); Universita degli Studi di Milano, Oncology and Haematology/Oncology Department, Milan (Italy)

    2017-11-15

    To assess the diagnostic accuracy of MRI performed using surface coils, with and without contrast medium, in predicting thyroid and cricoid cartilage infiltration in laryngeal tumours, and to investigate whether the radiologist's experience influences diagnostic accuracy. We retrospectively enrolled patients with biopsy-proven laryngeal cancer who had undergone preoperative staging MRI and open surgery. Two radiologists with different experience (senior vs. junior) reviewed the MR images without (session A1) and with contrast medium (session A2) separately. We calculated the accuracy of MRI with and without contrast medium in detecting infiltration of the thyroid and cricoid cartilages. Interobserver agreement was calculated by Cohen's Kappa (k). Forty-two patients were enrolled, for a total of 62 cartilages. In session A1 the senior and junior radiologists showed an accuracy of 85% and 71%, respectively, with k = 0.53 (0.33-0.72). In session A2 the senior and junior radiologists showed an accuracy of 84% and 77%, respectively, with k = 0.68 (0.49-0.86). Staging of laryngeal tumours with surface coil MRI showed good diagnostic accuracy in assessing cartilaginous infiltration. We observed similar values of diagnostic accuracy for the analysis performed with and without contrast medium for the senior radiologist. (orig.)

  4. Intravenous contrast medium administration at 128 multidetector row CT pulmonary angiography: Bolus tracking versus test bolus and the implications for diagnostic quality and effective dose

    International Nuclear Information System (INIS)

    Rodrigues, J.C.L.; Mathias, H.; Negus, I.S.; Manghat, N.E.; Hamilton, M.C.K.

    2012-01-01

    Aim: To investigate the effects of a test bolus protocol contrast medium administration on diagnostic image quality in computed tomography pulmonary angiography (CTPA). Materials and methods: Fifty patients referred for exclusion of pulmonary embolism underwent CTPA using a test bolus protocol CTPA at 120 kVp and were compared with 50 patients undergoing CTPA using a standard bolus-tracking protocol at 120 kVp, via assessment of attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) seen in the pulmonary arteries (PAs). An additional group of 10 non-obese patients who underwent CTPA using a test bolus protocol performed at 100 kVp were also analysed. Mean effective dose was calculated from the dose–length product, using standard conversion factors. Results: The test bolus protocol showed significantly higher attenuation, SNR, and CNR in the pulmonary vasculature down to the segmental level compared to bolus-tracking CTPA (p < 0.0001). There was no significant difference in effective dose between the test bolus and bolus tracking cohorts. The additional group of test bolus CTPA examinations performed at 100 kVp had a significantly reduced effective dose in comparison to both test bolus CTPA at 120 kVp and bolus-tracking CTPA at 120 kVp (p < 0.005) yet maintained mean PA attenuation to segmental level significantly better than bolus-tracking CTPA performed at 120 kVp and comparable to the test bolus cohort performed at 120 kVp. Conclusion: Test bolus contrast administration should be used as an optimal protocol. Performing test bolus CTPA at 100 kVp, as opposed to 120 kVp, significantly reduces dose without compromising PA attenuation in non-obese subjects.

  5. Indirect MR venography: contrast medium protocols, postprocessing and combination in diagnosing pulmonary emboli with MRI

    International Nuclear Information System (INIS)

    Kluge, A.; Bachmann, G.; Rominger, M.; Schoenburg, M.

    2004-01-01

    Purpose: Integration of MR venography in a comprehensive MR imaging protocol in patients with suspected pulmonary embolism (PE) and evaluation of contrast media dosage, timing and postprocessing for diagnostic accuracy. Materials and Methods: Fortyeight consecutive inpatients with suspected PE or deep vein thrombosis were examined by MR venography according to one of the following protocols: protocol I: MR venography only, 0.25 mmol/kg bodyweight (BW) Gadopentate dimeglumine(Gd-DTPA) as single dose, bolus timing; protocol II: MR angiography of pulmonary arteries with a cumulative dosage of 0.25 mmol/kg contrast media, modification of coil setting for MR venography without further contrast media application; protocol III: as protocol II but with 0.125 mmol/kg BW, followed by MR venography. Signal-to-noise ratio, contrast-to-noise ratio, number of definable vascular segments and image quality were evaluated. The results were compared to conventional bilateral venography. Results: All MR venography examinations were of diagnostic quality and the examination time was below 10 min. MR venography could be performed in all 48 patients comparted to 43 of 48 patients for conventional venography. Significantly more superficial and deep veins of the leg could be visualized by MR venography (94% compared to 83% for conventional venography). Sensitivity and specificity were 100% and 92%, respectively. Quality differed significantly between 0.125 mmol/kg (protocol III) and 0.25 mmol/kg Gd-DTPA (protocols I and II) while timing did not influence quality (protocol I vs. II). (orig.) [de

  6. Paediatric cardiac catheterization. Controlled, randomized study of two iodinated contrast media: iopromide 300 and ioxaglate 320 mgI/ml

    International Nuclear Information System (INIS)

    Amiel, M.; Revel, D.

    1989-01-01

    Thirty-one children were included in a prospective randomized trial comparing a new non-ionic contrast medium, iopromide 300 and the ionic low osmolar contrast medium, ioxaglate 320 mgI/ml in pediatric cardiac catheterization. There were fewer adverse effects with iopromide but no statistically significant difference was demonstrated in this small population, with a very low incidence of allergoid reactions; this tendency was confirmed by meta-analysis of the multicentre study [fr

  7. Double blind evaluation of the effects of various contrast media on extremity veins in the dog

    International Nuclear Information System (INIS)

    Laerum, F.; Dehner, L.P.; Rysavy, J.; Amplatz, K.; Minnesota Univ., Minneapolis

    1987-01-01

    Canine superficial extremity veins were examined grossly and microscopically in a double blind fashion for endothelial damage and phlebitis one hour and four days after the injection of ionic monomeric or dimeric, and non-ionic monomeric, 300 mg I/ml, contrast media. Superficial veins of all four extremities and the tail vein were injected with the same amounts of contrast medium after application of tourniquets for 20 minutes following the injections. Silver staining and prefixation of the veins were done in situ. The specimens were evaluated together with cross-sectioned, hematoxylin-eosin stained biopsies. On the basis of a randomized study of 77 dogs, endothelial damage or thrombosis caused by various contrast media as seen in man was not demonstrated. This may be due to species differences. It is postulated that canine endothelium may have a higher resistance to contrast medium injury than human endothelium. (orig.)

  8. B-mode and contrast-enhanced sonographic assessment of accessory spleen in the dog.

    Science.gov (United States)

    Rossi, Federica; Rabba, Silvia; Vignoli, Massimo; Haers, Hendrik; Terragni, Rossella; Saunders, Jimmy H

    2010-01-01

    Four dogs with an accessory spleen are described. The accessory spleens appeared as a round-to-triangular structure located in the perisplenic area. They were homogeneous and isoechoic with the adjacent spleen. Contrast-enhanced ultrasound was performed using a second generation microbubble contrast medium (sulfur hexafluoride). The type and timing of enhancement of the accessory spleen was similar to that of the parent spleen. Contrast-enhanced ultrasound is a noninvasive modality useful in distinguishing an accessory spleen from a mass of another origin.

  9. Clustering procedures for the optimal selection of data sets from multiple crystals in macromolecular crystallography.

    Science.gov (United States)

    Foadi, James; Aller, Pierre; Alguel, Yilmaz; Cameron, Alex; Axford, Danny; Owen, Robin L; Armour, Wes; Waterman, David G; Iwata, So; Evans, Gwyndaf

    2013-08-01

    The availability of intense microbeam macromolecular crystallography beamlines at third-generation synchrotron sources has enabled data collection and structure solution from microcrystals of structure. The associated analysis and merging of multi-crystal data is currently a manual and time-consuming step. Here, a computer program, BLEND, that has been written to assist with and automate many of the steps in this process is described. It is demonstrated how BLEND has successfully been used in the solution of a novel membrane protein.

  10. Investigation of the biochemical state of paramagnetic ions in vivo using the magnetic field dependence of 1/T1 of tissue protons (NMRD profile): applications to contrast agents for magnetic resonance imaging

    International Nuclear Information System (INIS)

    Koenig, S.H.; Brown, R.D. III; Spiller, M.; Wolf, G.L.

    1988-01-01

    Nuclear magnetic relaxation dispersion (NMRD) profiles of protons are obtained in homogenous aqueous solutions of the paramagnetic ions, Mn 2+ and Gd 3+ and their chelate and macromolecular complexes in vitro, giving information regarding the biochemical state of these ions. Similarly NMRD profiles of protons of excised rabbit tissues containing Mn 2+ and Gd 3+ complexes are obtained. These NMRD profiles are shown to be very useful for determining the fate of potentially useful paramagnetic NMR imaging contrast agents in vivo. (U.K.)

  11. An integrated native mass spectrometry and top-down proteomics method that connects sequence to structure and function of macromolecular complexes

    Science.gov (United States)

    Li, Huilin; Nguyen, Hong Hanh; Ogorzalek Loo, Rachel R.; Campuzano, Iain D. G.; Loo, Joseph A.

    2018-02-01

    Mass spectrometry (MS) has become a crucial technique for the analysis of protein complexes. Native MS has traditionally examined protein subunit arrangements, while proteomics MS has focused on sequence identification. These two techniques are usually performed separately without taking advantage of the synergies between them. Here we describe the development of an integrated native MS and top-down proteomics method using Fourier-transform ion cyclotron resonance (FTICR) to analyse macromolecular protein complexes in a single experiment. We address previous concerns of employing FTICR MS to measure large macromolecular complexes by demonstrating the detection of complexes up to 1.8 MDa, and we demonstrate the efficacy of this technique for direct acquirement of sequence to higher-order structural information with several large complexes. We then summarize the unique functionalities of different activation/dissociation techniques. The platform expands the ability of MS to integrate proteomics and structural biology to provide insights into protein structure, function and regulation.

  12. NATO Advanced Study Institute on Evolving Methods for Macromolecular Gystallography

    CERN Document Server

    Read, Randy J

    2007-01-01

    X-ray crystallography is the pre-eminent technique for visualizing the structures of macromolecules at atomic resolution. These structures are central to understanding the detailed mechanisms of biological processes, and to discovering novel therapeutics using a structure-based approach. As yet, structures are known for only a small fraction of the proteins encoded by human and pathogenic genomes. To counter the myriad modern threats of disease, there is an urgent need to determine the structures of the thousands of proteins whose structure and function remain unknown. This volume draws on the expertise of leaders in the field of macromolecular crystallography to illuminate the dramatic developments that are accelerating progress in structural biology. Their contributions span the range of techniques from crystallization through data collection, structure solution and analysis, and show how modern high-throughput methods are contributing to a deeper understanding of medical problems.

  13. Evaluation of liver parenchyma and perfusion using dynamic contrast-enhanced computed tomography and contrast-enhanced ultrasonography in captive green iguanas (Iguana iguana) under general anesthesia.

    Science.gov (United States)

    Nardini, Giordano; Di Girolamo, Nicola; Leopardi, Stefania; Paganelli, Irene; Zaghini, Anna; Origgi, Francesco C; Vignoli, Massimo

    2014-05-13

    Contrast-enhanced diagnostic imaging techniques are considered useful in veterinary and human medicine to evaluate liver perfusion and focal hepatic lesions. Although hepatic diseases are a common occurrence in reptile medicine, there is no reference to the use of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) to evaluate the liver in lizards. Therefore, the aim of this study was to evaluate the pattern of change in echogenicity and attenuation of the liver in green iguanas (Iguana iguana) after administration of specific contrast media. An increase in liver echogenicity and density was evident during CEUS and CECT, respectively. In CEUS, the mean ± SD (median; range) peak enhancement was 19.9% ± 7.5 (18.3; 11.7-34.6). Time to peak enhancement was 134.0 ± 125.1 (68.4; 59.6-364.5) seconds. During CECT, first visualization of the contrast medium was at 3.6 ± 0.5 (4; 3-4) seconds in the aorta, 10.7 ± 2.2 (10.5; 7-14) seconds in the hepatic arteries, and 15 ± 4.5 (14.5; 10-24) seconds in the liver parenchyma. Time to peak was 14.1 ± 3.4 (13; 11-21) and 31 ± 9.6 (29; 23-45) seconds in the aorta and the liver parenchyma, respectively. CEUS and dynamic CECT are practical means to determine liver hemodynamics in green iguanas. Distribution of contrast medium in iguana differed from mammals. Specific reference ranges of hepatic perfusion for diagnostic evaluation of the liver in iguanas are necessary since the use of mammalian references may lead the clinician to formulate incorrect diagnostic suspicions.

  14. Utility of intravenous nonionic contrast media for abdominal CT in patients with renal dysfunction

    International Nuclear Information System (INIS)

    Craig, B.M.; Alpern, M.B.; Sandler, M.A.; Pearlberg, J.L.; Swanson, D.P.

    1987-01-01

    The safety and efficacy of a nonionic contrast medium (NICM) for CT enhancements in patients with renal dysfunction were evaluated. Thirty consecutive patients referred for abdominal CT with a serum creatinine (SCr) level over 5 mg/dL or a SCr level of 2-5 mg/dL and another risk factor (e.g., diabetes, single kidney) received NICM. Each was matched with a control who received the same 150-mL bolus of a conventional medium. No adverse reactions or significant alterations in SCr values were found in the NICM patients. No significant differences between the patient groups were found in blinded subjective image quality ratings or measured attenuation values of a parenchymal organs and vascular structures (with the exception of less renal enhancement in the NICM patients, reflecting their renal dysfunction). Use of an NICM is a safe and effective method for contrast medium-enhanced CT in patients with renal dysfunction

  15. Contrast enhanced magnetic resonance imaging of the brain using gadolinium-DTPA

    International Nuclear Information System (INIS)

    Valk, J.; Slegte, R.G.M. de; Crezee, F.C.; Hazenberg, G.J.; Thjaha, S.I.; Nauta, J.J.P.; Vrije Univ., Amsterdam; Vrije Univ., Amsterdam; Vrije Univ., Amsterdam

    1987-01-01

    This report concerns a clinical trial with gadolinium-DTPA (Gd-DTPA) as an intravenous contrast medium for magnetic resonance imaging (MRI) in patients with disorders of the central nervous system. Fifty patients, 30 females and 20 males, were examined without and with Gd-GTPA. The contrast medium was well tolerated by all patients. The results of MRI scanning without and with Gd-DTPA and those obtained with computed tomography (CT) using intravenous contrast enhancement were compared. This investigation comprised mainly patients with intracranial tumors, multiple sclerosis, and nasopharyngeal tumors. The results may be summarized as follows: 1) MRI with Gd-DTPA (MRI+) gave better results than MRI without Gd as regards delineation of the lesion, blood vessels and edema in cerebral tumors, pituitary adenomas and acute forms of multiple sclerosis (MS). MRI+ was better than CT in 32 of the 50 cases examined; with intracerebral tumors it was better in 15 out of 18 cases. 3) MRI+ was always better than CT in patients with MS. In 3 out of 7 cases MRI demonstrated the acute MS lesions. 4) MRI+ seemed to have advantages also in nasopharyngeal tumors as ascertained from this limited experience. (orig.)

  16. Monochromatic Spectral Computed Tomography with Low Iodine Concentration Contrast Medium in a Rabbit VX2 Liver Model:: Investigation of Image Quality and Detection Rate.

    Science.gov (United States)

    Zhou, Yue; Xu, Han; Hou, Ping; Dong, Jun Q; Wang, Ming Y; Gao, Jian B

    2016-04-01

    This study aimed to validate the feasibility of using virtual monochromatic spectral computed tomography (CT) with isotonic low iodine concentration contrast medium for VX2 hepatic tumors. Sixty New Zealand white rabbits with implanted VX2 hepatic tumors underwent two-phase contrast-enhanced spectral CT imaging on the 14th day after tumor implantation. They were randomly divided into groups A, B, and C, with 20 rabbits each (group A: 270 mg I/mL, monochromatic spectral images; group B: 370 mg I/mL, conventional 120 kVp images, 100% filtered back projection [FBP]; group C: 270 mg I/mL, conventional 120 kVp images, 100% FBP). Group A was further divided into two subgroups (subgroup A1: 100% FBP; subgroup A2: 50% FBP + 50% adaptive statistical iterative reconstruction). Objective evaluation (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], and image noise), subjective rating score (image noise score, anatomical details score, overall image quality score, and lesion conspicuity score), CT dose index volume, and dose length product were compared between groups during two-phase contrast enhancement. The detection rates of the four groups were calculated as percentages. Image noise (SNR and CNR) among the four groups was statistically significant (P noise in group A2 was lower than in group A1, but higher than that in groups B and C (P noise score of group A2 was higher than that of the other three groups. In terms of the anatomic details score, the overall image quality score, and the lesion conspicuity score, the images of group A2 were superior to that of groups A1 and C. For hepatic tumor diameters more than or equal to 1.0 cm and less than 3.0 cm, group A achieved a higher detection rate than groups B and C. The CT dose index volume, dose length product, and effective dose in group A were significantly lower than that in groups B and C (P noise, increase detection rate for small tumors, and decrease radiation dose and iodine load in

  17. Asymptotic expansions for high-contrast elliptic equations

    KAUST Repository

    Calo, Victor M.; Efendiev, Yalchin R.; Galvis, Juan

    2014-01-01

    In this paper, we present a high-order expansion for elliptic equations in high-contrast media. The background conductivity is taken to be one and we assume the medium contains high (or low) conductivity inclusions. We derive an asymptotic expansion with respect to the contrast and provide a procedure to compute the terms in the expansion. The computation of the expansion does not depend on the contrast which is important for simulations. The latter allows avoiding increased mesh resolution around high conductivity features. This work is partly motivated by our earlier work in [Domain decomposition preconditioners for multiscale flows in high-contrast media, Multiscale Model Simul. 8 (2010) 1461-1483] where we design efficient numerical procedures for solving high-contrast problems. These multiscale approaches require local solutions and our proposed high-order expansion can be used to approximate these local solutions inexpensively. In the case of a large-number of inclusions, the proposed analysis can help to design localization techniques for computing the terms in the expansion. In the paper, we present a rigorous analysis of the proposed high-order expansion and estimate the remainder of it. We consider both high-and low-conductivity inclusions. © 2014 World Scientific Publishing Company.

  18. Asymptotic expansions for high-contrast elliptic equations

    KAUST Repository

    Calo, Victor M.

    2014-03-01

    In this paper, we present a high-order expansion for elliptic equations in high-contrast media. The background conductivity is taken to be one and we assume the medium contains high (or low) conductivity inclusions. We derive an asymptotic expansion with respect to the contrast and provide a procedure to compute the terms in the expansion. The computation of the expansion does not depend on the contrast which is important for simulations. The latter allows avoiding increased mesh resolution around high conductivity features. This work is partly motivated by our earlier work in [Domain decomposition preconditioners for multiscale flows in high-contrast media, Multiscale Model Simul. 8 (2010) 1461-1483] where we design efficient numerical procedures for solving high-contrast problems. These multiscale approaches require local solutions and our proposed high-order expansion can be used to approximate these local solutions inexpensively. In the case of a large-number of inclusions, the proposed analysis can help to design localization techniques for computing the terms in the expansion. In the paper, we present a rigorous analysis of the proposed high-order expansion and estimate the remainder of it. We consider both high-and low-conductivity inclusions. © 2014 World Scientific Publishing Company.

  19. Contrast-induced encephalopathy following cardiac catheterization.

    Science.gov (United States)

    Spina, Roberto; Simon, Neil; Markus, Romesh; Muller, David Wm; Kathir, Krishna

    2017-08-01

    To describe the epidemiology, pathophysiology, clinical presentation, and management of contrast-induced encephalopathy (CIE) following cardiac catheterization. CIE is an acute, reversible neurological disturbance directly attributable to the intra-arterial administration of iodinated contrast medium. The PubMed database was searched and all cases in the literature were retrieved and reviewed. 52 reports of CIE following cardiac catheterization were found. Encephalopathy, motor and sensory disturbances, vision disturbance, opthalmoplegia, aphasia, and seizures have been reported. Transient cortical blindness is the most commonly reported neurological syndrome, occurring in approximately 50% of cases. The putative mechanism involves disruption of the blood brain barrier and direct neuronal injury. Contrast-induced transient vasoconstriction has also been implicated. Symptoms typically appear within minutes to hours of contrast administration and resolve entirely within 24-48 hr. Risk factors may include hypertension, diabetes mellitus, renal impairment, the administration of large volumes of iodinated contrast, percutaneous coronary intervention or selective angiography of internal mammary grafts, and previous adverse reaction to iodinated contrast. Characteristic findings on cerebral imaging include cortical and sub-cortical contrast enhancement on computed tomography (CT). Imaging findings in CIE may mimic subarachnoid hemorrhage or cerebral ischemia; the Hounsfield scale on CT and the apparent diffusion coefficient on magnetic resonance imaging (MRI) are useful imaging tools in distinguishing these entities. In some cases, brain imaging is normal. Prognosis is excellent with supportive management alone. CIE tends to recur, although re-challenge with iodinated contrast without adverse effects has been documented. CIE is an important clinical entity to consider in the differential diagnosis of stroke following cardiac catheterization. Given that prognosis is

  20. On macromolecular refinement at subatomic resolution with interatomic scatterers

    Energy Technology Data Exchange (ETDEWEB)

    Afonine, Pavel V., E-mail: pafonine@lbl.gov; Grosse-Kunstleve, Ralf W.; Adams, Paul D. [Lawrence Berkeley National Laboratory, One Cyclotron Road, BLDG 64R0121, Berkeley, CA 94720 (United States); Lunin, Vladimir Y. [Institute of Mathematical Problems of Biology, Russian Academy of Sciences, Pushchino 142290 (Russian Federation); Urzhumtsev, Alexandre [IGMBC, 1 Rue L. Fries, 67404 Illkirch and IBMC, 15 Rue R. Descartes, 67084 Strasbourg (France); Faculty of Sciences, Nancy University, 54506 Vandoeuvre-lès-Nancy (France); Lawrence Berkeley National Laboratory, One Cyclotron Road, BLDG 64R0121, Berkeley, CA 94720 (United States)

    2007-11-01

    Modelling deformation electron density using interatomic scatters is simpler than multipolar methods, produces comparable results at subatomic resolution and can easily be applied to macromolecules. A study of the accurate electron-density distribution in molecular crystals at subatomic resolution (better than ∼1.0 Å) requires more detailed models than those based on independent spherical atoms. A tool that is conventionally used in small-molecule crystallography is the multipolar model. Even at upper resolution limits of 0.8–1.0 Å, the number of experimental data is insufficient for full multipolar model refinement. As an alternative, a simpler model composed of conventional independent spherical atoms augmented by additional scatterers to model bonding effects has been proposed. Refinement of these mixed models for several benchmark data sets gave results that were comparable in quality with the results of multipolar refinement and superior to those for conventional models. Applications to several data sets of both small molecules and macromolecules are shown. These refinements were performed using the general-purpose macromolecular refinement module phenix.refine of the PHENIX package.

  1. Research of Raman spectroscopy to detect subsurface ingredient under non-transparent medium

    International Nuclear Information System (INIS)

    Zhang Xiaohua; Zhang Ji; Zhang Haifeng; Lu Jianxin; Sun Shuying; Wang Leijian; Xu Yongsheng; Wang Xiaojie; Tang Xiuzhang

    2014-01-01

    The measurement and contrast of NaNO 3 powder concealed in opaque/semi-transparent plastic bottles were carried out through conventional Raman spectroscopy configuration and spatially offset Raman spectroscopy configuration individually. The action mechanism why the spatially offset Raman spectroscopy can effectively detect the medium concealed in the non-transparent bottle was analyzed. The detection depth of conventional Raman spectroscopy is small and the ingredient of the subsurface under non-transparent medium can not be detected, and the spatially offset Raman spectroscopy broke through the neck of the conventional Raman spectroscopy detection. The measurement and identification of the substance concealed in the non-transparent medium (opaque/semi-transparent plastic bottle) were realized. (authors)

  2. Gadolinium DTPA as oral contrast medium for MRT of the pancreas

    International Nuclear Information System (INIS)

    Neumann, K.; Kaminsky, S.; Gogoll, M.; Langer, M.; Felix, R.

    1991-01-01

    52 patients with normal pancreas, pancreatitis and pancreatic tumors were examined by magnetic resonance imaging (Magnetom 0,5 T). Using T 1 -, proton density- and T 2 -weighted spin-echo sequences images were obtained before and after oral administration of Gadolinium-DTPA (Gd-DTPA, 1 mM, 15 g/l Mannit, 5-13 ml/kg). Gd-DTPA resulted in hyperintense labeling of small bowel in all sequences and improved visualization of pancreatic head, body and tail in 15, 14 and 7 of 27 patients with normal pancreas and in 17, 8 and 6 of 25 patients with diseased pancreas. Better delineation of pseudocysts and tumorous gut wall invasion were diagnostically profitable. With regard to motion artifact reduced MRI of the intestine using fast sequences Gd-DTPA may be a suitable oral contrast agent to improve the imaging of the pancreas. (orig.) [de

  3. Contrast enhancement of cranial lesions in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lewander, R; Bergstroem, M; Bergvall, U [Kungliga Karolinska Mediko-Kirurgiska Inst., Stockholm (Sweden)

    1978-01-01

    The time course of enhancement in apparently normal brain tissue, edema and focal lesions during 30 to 60 min after intravenous injection of vascular contrast medium was evaluated in a series of 41 pateints with differnt intracranial lesions. The attenuation of apparently normal unenhanced brain tissue varied with the level of the scan, mainly an effect of beam hardening. Different types of enhancement response are discussed in terms of a 3-compartment model. The differential diagnostic potential of contrast enhancement in the early phase needs further evaluation using instruments with short scanning time, while the late phase of enhancement must be recorded with the use of a reliable head fixation to provide reproducibility of repeat measurements.

  4. Timely deposition of macromolecular structures is necessary for peer review

    International Nuclear Information System (INIS)

    Joosten, Robbie P.; Soueidan, Hayssam; Wessels, Lodewyk F. A.; Perrakis, Anastassis

    2013-01-01

    Deposition of crystallographic structures should be concurrent with or prior to manuscript submission for peer review, enabling validation and increasing reliability of the PDB. Most of the macromolecular structures in the Protein Data Bank (PDB), which are used daily by thousands of educators and scientists alike, are determined by X-ray crystallography. It was examined whether the crystallographic models and data were deposited to the PDB at the same time as the publications that describe them were submitted for peer review. This condition is necessary to ensure pre-publication validation and the quality of the PDB public archive. It was found that a significant proportion of PDB entries were submitted to the PDB after peer review of the corresponding publication started, and many were only submitted after peer review had ended. It is argued that clear description of journal policies and effective policing is important for pre-publication validation, which is key in ensuring the quality of the PDB and of peer-reviewed literature

  5. Timely deposition of macromolecular structures is necessary for peer review

    Energy Technology Data Exchange (ETDEWEB)

    Joosten, Robbie P. [Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Soueidan, Hayssam; Wessels, Lodewyk F. A. [Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX, Amsterdam (Netherlands); Perrakis, Anastassis, E-mail: a.perrakis@nki.nl [Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands)

    2013-12-01

    Deposition of crystallographic structures should be concurrent with or prior to manuscript submission for peer review, enabling validation and increasing reliability of the PDB. Most of the macromolecular structures in the Protein Data Bank (PDB), which are used daily by thousands of educators and scientists alike, are determined by X-ray crystallography. It was examined whether the crystallographic models and data were deposited to the PDB at the same time as the publications that describe them were submitted for peer review. This condition is necessary to ensure pre-publication validation and the quality of the PDB public archive. It was found that a significant proportion of PDB entries were submitted to the PDB after peer review of the corresponding publication started, and many were only submitted after peer review had ended. It is argued that clear description of journal policies and effective policing is important for pre-publication validation, which is key in ensuring the quality of the PDB and of peer-reviewed literature.

  6. A beamline for macromolecular crystallography at the Advanced Light Source

    International Nuclear Information System (INIS)

    Padmore, H.A.; Earnest, T.; Kim, S.H.; Thompson, A.C.; Robinson, A.L.

    1994-08-01

    A beamline for macromolecular crystallography has been designed for the ALS. The source will be a 37-pole wiggler with a, 2-T on-axis peak field. The wiggler will illuminate three beamlines, each accepting 3 mrad of horizontal aperture. The central beamline will primarily be used for multiple-wavelength anomalous dispersion measurements in the wavelength range from 4 to 0.9 angstrom. The beamline optics will comprise a double-crystal monochromator with a collimating pre-mirror and a double-focusing mirror after the monochromator. The two side stations will be used for fixed-wavelength experiments within the wavelength range from 1.5 to 0.95 angstrom. The optics will consist of a conventional vertically focusing cylindrical mirror followed by an asymmetrically cut curved-crystal monochromator. This paper presents details of the optimization of the wiggler source for crystallography, gives a description of the beamline configuration, and discusses the reasons for the choices made

  7. Clustering procedures for the optimal selection of data sets from multiple crystals in macromolecular crystallography

    Science.gov (United States)

    Foadi, James; Aller, Pierre; Alguel, Yilmaz; Cameron, Alex; Axford, Danny; Owen, Robin L.; Armour, Wes; Waterman, David G.; Iwata, So; Evans, Gwyndaf

    2013-01-01

    The availability of intense microbeam macromolecular crystallography beamlines at third-generation synchrotron sources has enabled data collection and structure solution from microcrystals of sets from many crystals of the same protein structure. The associated analysis and merging of multi-crystal data is currently a manual and time-consuming step. Here, a computer program, BLEND, that has been written to assist with and automate many of the steps in this process is described. It is demonstrated how BLEND has successfully been used in the solution of a novel membrane protein. PMID:23897484

  8. Errors in macromolecular synthesis after stress. A study of the possible protective role of the small heat shock proteinsBiochemistry

    NARCIS (Netherlands)

    Marin Vinader, L.

    2006-01-01

    The general goal of this thesis was to gain insight in what small heat shock proteins (sHsps) do with respect to macromolecular synthesis during a stressful situation in the cell. It is known that after a non-lethal heat shock, cells are better protected against a subsequent more severe heat shock,

  9. Ultrasound in Biomedical Engineering: Ultrasound Microbubble Contrast Agents Promote Transdermal Permeation of Drugs

    OpenAIRE

    Ai-Ho Liao

    2016-01-01

    This report discusses a new development in the use of ultrasound microbubble contrast agents on transdermal drug delivery. The medium surrounding the microbubbles at the optimum concentration from liquid to gel can be modified and it can still achieve the same enhancement for transdermal drug permeation as liquid medium. It was also found that under the same ultrasound power density, microbubbles of larger particle sizes can extend the penetration depths of dye at the phantom surface.

  10. The diagnostic effectiveness of contrast media in the excretory urography in dogs

    International Nuclear Information System (INIS)

    Velesova, M.; Ledecky, V.

    2005-01-01

    A clinical study was conducted to investigate the use of four different positive contrast media, Omnipaque (Nycomed Imaging As.), Optiray (Maliincrodt Medical GmbH), Ultravist (Schering AG), and Urografin (Schering AG) in normograde excretory urography. Investigations were carried out on thirteen dogs. Each group of dogs was administered a different contrast medium. Radiographs were obtained immediately after the administration of contrast media and after a lapse of 5, 10 and 15 minutes. The effectiveness of the application was evaluated by assessing the radiographs of abdominal cavities in ventro-dorsal and latero-lateral positions. None of the dogs showed pronounced side effect after the application of contrast media. Ectopic ureter was diagnosed in three and a prostate cyst in one of the patients. Our results showed that Omnipaque and Ultravist were the contrast agents most suitable for the examination of the urinary apparatus by intravenous contrast excretory urography. Their advantage is that visualisation of the kidneys and ureters achieved by these media are sufficiently long and contrastive

  11. CT enhancement of acute cerebral infarction following long-term continuous contrast infusion

    International Nuclear Information System (INIS)

    Ito, Umeo; Seida, Mitsuru; Tomida, Shuichi; Inaba, Yutaka.

    1985-01-01

    In this experimental study, we employed a long-term (3 hours) continuous-drip infusion of the contrast medium (200 ml of meglumine amidtrizoate) rather than the conventional bolus injection. On admission, four-vessel angiography was performed on all 14 patients. Within 3 days after the onset of the disease, CT scan was carried out repeatedly just prior to contrast infusion, immediately after the end of the continuous-contrast infusion, and additionally, in 4 cases, 3 hours after the end of the contrast infusion. The Haunsfield number was calculated in 3 regions of interest (Radius 5) in the infarction. Positive enhancement was observed in 10 out of the 14 patients (71 %). Among them, 4 out of 5 patients in whom no vascular obstraction on angiography, but marked low-density areas with a mass effect on CT were observed, showed moderate to marked enhancement. In these 4 patients, a temporary cerebral ischemia due to vascular embolization was considered. From the other 4 patients in whom the additional CT scan was performed 3 hours after the end of the contrast infusion, a blood sample was obtained at each of the 3 CT scannings. The iodine concentrations of the blood samples were measured, and their Haunsfield numbers were calculated in the water phantom. The above two parameters were well correlated in a linear function. Among the 4 patients, Gado's tissue-blood ratio (the Haunsfield number of the CT lesion is divided by that of the blood sample) was more than 17.2 % immediately after, and more than 54.7 % 3 hours after, the contrast infusion. Thus, we could conclude that the break-down of the BBB which was demonstrated by a long-term high-blood-concentration level of the contrast medium is an earlier event in human cerebral infarction than is usually accepted. The findings are compatible with our results in animal experiments. (author)

  12. Site-selective electroless nickel plating on patterned thin films of macromolecular metal complexes.

    Science.gov (United States)

    Kimura, Mutsumi; Yamagiwa, Hiroki; Asakawa, Daisuke; Noguchi, Makoto; Kurashina, Tadashi; Fukawa, Tadashi; Shirai, Hirofusa

    2010-12-01

    We demonstrate a simple route to depositing nickel layer patterns using photocross-linked polymer thin films containing palladium catalysts, which can be used as adhesive interlayers for fabrication of nickel patterns on glass and plastic substrates. Electroless nickel patterns can be obtained in three steps: (i) the pattern formation of partially quaterized poly(vinyl pyridine) by UV irradiation, (ii) the formation of macromolecular metal complex with palladium, and (iii) the nickel metallization using electroless plating bath. Metallization is site-selective and allows for a high resolution. And the resulting nickel layered structure shows good adhesion with glass and plastic substrates. The direct patterning of metallic layers onto insulating substrates indicates a great potential for fabricating micro/nano devices.

  13. Development of low-dose photon-counting contrast-enhanced tomosynthesis with spectral imaging.

    Science.gov (United States)

    Schmitzberger, Florian F; Fallenberg, Eva Maria; Lawaczeck, Rüdiger; Hemmendorff, Magnus; Moa, Elin; Danielsson, Mats; Bick, Ulrich; Diekmann, Susanne; Pöllinger, Alexander; Engelken, Florian J; Diekmann, Felix

    2011-05-01

    To demonstrate the feasibility of low-dose photon-counting tomosynthesis in combination with a contrast agent (contrast material-enhanced tomographic mammography) for the differentiation of breast cancer. All studies were approved by the institutional review board, and all patients provided written informed consent. A phantom model with wells of iodinated contrast material (3 mg of iodine per milliliter) 1, 2, 5, 10, and 15 mm in diameter was assessed. Nine patients with malignant lesions and one with a high-risk lesion (atypical papilloma) were included (all women; mean age, 60.7 years). A multislit photon-counting tomosynthesis system was utilized (spectral imaging) to produce both low- and high-energy tomographic data (below and above the k edge of iodine, respectively) in a single scan, which allowed for dual-energy visualization of iodine. Images were obtained prior to contrast material administration and 120 and 480 seconds after contrast material administration. Four readers independently assessed the images along with conventional mammograms, ultrasonographic images, and magnetic resonance images. Glandular dose was estimated. Contrast agent was visible in the phantom model with simulated spherical tumor diameters as small as 5 mm. The average glandular dose was measured as 0.42 mGy per complete spectral imaging tomosynthesis scan of one breast. Because there were three time points (prior to contrast medium administration and 120 and 480 seconds after contrast medium administration), this resulted in a total dose of 1.26 mGy for the whole procedure in the breast with the abnormality. Seven of 10 cases were categorized as Breast Imaging Reporting and Data System score of 4 or higher by all four readers when reviewing spectral images in combination with mammograms. One lesion near the chest wall was not captured on the spectral image because of a positioning problem. The use of contrast-enhanced tomographic mammography has been demonstrated successfully in

  14. Evaluation of the canine tympanic membrane by positive contrast ear canalography

    International Nuclear Information System (INIS)

    Trower, N.D.; Gregory, S.P.; Renfrew, H.; Lamb, C.R.

    1998-01-01

    Positive contrast ear canalography was described briefly in 1973 as a method for detecting rupture of the tympanic membrane in dogs with otitis media. The purpose of this study was to evaluate the sensitivity and usefulness of the technique. The ears of 10 normal canine cadavers and 31 dogs with clinical signs of ear disease were examined using otoscopy, radiography and contrast radiography after infusing 2 to 5 ml of positive contrast medium into the ear canals. These examinations were repeated in the cadavers after the tympanic membrane had been punctured with a Spreull needle. In the cadavers 14 of 19 (74 per cent) of the tympanic membranes were visible otoscopically; contrast medium did not enter the tympanic bulla of any of the ears before the tympanic membrane was ruptured, but was visible in the bulla in every ear after rupture. In the clinical study, 40 of 61 (66 per cent) of the tympanic membranes were visible otoscopically, and 12 appeared to be ruptured. Radiographic signs of otitis media (increased opacity and/or thickening of the tympanic bulla) were identified in seven ears. Canalography was positive for rupture of the tympanic membrane in 13 ears, including four in which it appeared to be intact otoscopically. In normal canine ears, canalography was a more accurate method for detecting iatrogenic tympanic membrane rupture than otoscopy. In dogs with ear disease, canalography may be more sensitive for otitis media than either otoscopy or survey radiography

  15. Contrast enhancement of mail piece images

    Science.gov (United States)

    Shin, Yong-Chul; Sridhar, Ramalingam; Demjanenko, Victor; Palumbo, Paul W.; Hull, Jonathan J.

    1992-08-01

    A New approach to contrast enhancement of mail piece images is presented. The contrast enhancement is used as a preprocessing step in the real-time address block location (RT-ABL) system. The RT-ABL system processes a stream of mail piece images and locates destination address blocks. Most of the mail pieces (classified into letters) show high contrast between background and foreground. As an extreme case, however, the seasonal greeting cards usually use colored envelopes which results in reduced contrast osured by an error rate by using a linear distributed associative memory (DAM). The DAM is trained to recognize the spectra of three classes of images: with high, medium, and low OCR error rates. The DAM is not forced to make a classification every time. It is allowed to reject as unknown a spectrum presented that does not closely resemble any that has been stored in the DAM. The DAM was fairly accurate with noisy images but conservative (i.e., rejected several text images as unknowns) when there was little ground and foreground degradations without affecting the nondegraded images. This approach provides local enhancement which adapts to local features. In order to simplify the computation of A and (sigma) , dynamic programming technique is used. Implementation details, performance, and the results on test images are presented in this paper.

  16. AutoDrug: fully automated macromolecular crystallography workflows for fragment-based drug discovery

    International Nuclear Information System (INIS)

    Tsai, Yingssu; McPhillips, Scott E.; González, Ana; McPhillips, Timothy M.; Zinn, Daniel; Cohen, Aina E.; Feese, Michael D.; Bushnell, David; Tiefenbrunn, Theresa; Stout, C. David; Ludaescher, Bertram; Hedman, Britt; Hodgson, Keith O.; Soltis, S. Michael

    2013-01-01

    New software has been developed for automating the experimental and data-processing stages of fragment-based drug discovery at a macromolecular crystallography beamline. A new workflow-automation framework orchestrates beamline-control and data-analysis software while organizing results from multiple samples. AutoDrug is software based upon the scientific workflow paradigm that integrates the Stanford Synchrotron Radiation Lightsource macromolecular crystallography beamlines and third-party processing software to automate the crystallography steps of the fragment-based drug-discovery process. AutoDrug screens a cassette of fragment-soaked crystals, selects crystals for data collection based on screening results and user-specified criteria and determines optimal data-collection strategies. It then collects and processes diffraction data, performs molecular replacement using provided models and detects electron density that is likely to arise from bound fragments. All processes are fully automated, i.e. are performed without user interaction or supervision. Samples can be screened in groups corresponding to particular proteins, crystal forms and/or soaking conditions. A single AutoDrug run is only limited by the capacity of the sample-storage dewar at the beamline: currently 288 samples. AutoDrug was developed in conjunction with RestFlow, a new scientific workflow-automation framework. RestFlow simplifies the design of AutoDrug by managing the flow of data and the organization of results and by orchestrating the execution of computational pipeline steps. It also simplifies the execution and interaction of third-party programs and the beamline-control system. Modeling AutoDrug as a scientific workflow enables multiple variants that meet the requirements of different user groups to be developed and supported. A workflow tailored to mimic the crystallography stages comprising the drug-discovery pipeline of CoCrystal Discovery Inc. has been deployed and successfully

  17. Nephrotoxicity of cyclosporin A and contrast media

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Larsen, S.; Skaarup, P.; Hemmingsen, L.; Dieperink, H.; Golman, K.; Herlev Hospital; Herlev Hospital; Centralsygehuset, Nykoebing Falster; Odense Sygehus; Malmoe Allmaenna Sjukhus

    1989-01-01

    Urine profiles (albumin, glucose, NAG, LDH, GGT and sodium) were followed for 22 h or 8 days after intravenous injection of diatrizoate, iohexol or saline in 30 adult Wistar rats in which nephrotoxicity was induced by daily peroral administration of 25 mg/kg body weight cyclosporin A over a 14-day period. Another 10 rats which had the vehicle of the cyclosporin A solution (placebo) and saline injected intravenously served as controls. The effect of iohexol and saline on the albumin excretion was similar, whereas diatrizoate increased it significantly. Both contrast media caused significantly increased excretion of all three enzymes. The contrast media had no effect on the excretion of glucose and sodium. Except for the fact that the excretion of NAG was significantly higher following iohexol than following diatrizoate 24 to 46 h after injection no significant differences between the two media were found from 24 h after injection among the rats given cyclosporin A. No contrast medium related changes were found by light microscopy of the kidneys. Neither iohexol nor diatrizoate potentiate acute cyclosporin A nephrotoxicity. (orig.)

  18. Leaching of organic acids from macromolecular organic matter by non-supercritical CO2

    Science.gov (United States)

    Sauer, P.; Glombitza, C.; Kallmeyer, J.

    2012-04-01

    The storage of CO2 in underground reservoirs is discussed controversly in the scientific literature. The worldwide search for suitable storage formations also considers coal-bearing strata. CO2 is already injected into seams for enhanced recovery of coal bed methane. However, the effects of increased CO2 concentration, especially on organic matter rich formations, are rarely investigated. The injected CO2 will dissolve in the pore water, causing a decrease in pH and resulting in acidic formation waters. Huge amounts of low molecular weight organic acids (LMWOAs) are chemically bound to the macromolecular matrix of sedimentary organic matter and may be liberated by hydrolysis, which is enhanced by the acidic porewater. Recent investigations outlined the importance of LMWOAs as a feedstock for microbial life in the subsurface [1]. Therefore, injection of CO2 into coal formations may result in enhanced nutrient supply for subsurface microbes. To investigate the effect of high concentrations of dissolved CO2 on the release of LMWOAs from coal we developed an inexpensive high-pressure high temperature system that allows manipulating the partial pressure of dissolved gases at pressures and temperatures up to 60 MPa and 120° C, respectively. In a reservoir vessel, gases are added to saturate the extraction medium to the desired level. Inside the extraction vessel hangs a flexible and inert PVDF sleeve (polyvinylidene fluoride, almost impermeable for gases), holding the sample and separating it from the pressure fluid. The flexibility of the sleeve allows for subsampling without loss of pressure. Coal samples from the DEBITS-1 well, Waikato Basin, NZ (R0 = 0.29, TOC = 30%). were extracted at 90° C and 5 MPa, either with pure or CO2-saturated water. Subsamples were taken at different time points during the extraction. The extracted LMWOAs such as formate, acetate and oxalate were analysed by ion chromatography. Yields of LMWOAs were higher with pure water than with CO2

  19. Macromolecular Crystal Growth by Means of Microfluidics

    Science.gov (United States)

    vanderWoerd, Mark; Ferree, Darren; Spearing, Scott; Monaco, Lisa; Molho, Josh; Spaid, Michael; Brasseur, Mike; Curreri, Peter A. (Technical Monitor)

    2002-01-01

    We have performed a feasibility study in which we show that chip-based, microfluidic (LabChip(TM)) technology is suitable for protein crystal growth. This technology allows for accurate and reliable dispensing and mixing of very small volumes while minimizing bubble formation in the crystallization mixture. The amount of (protein) solution remaining after completion of an experiment is minimal, which makes this technique efficient and attractive for use with proteins, which are difficult or expensive to obtain. The nature of LabChip(TM) technology renders it highly amenable to automation. Protein crystals obtained in our initial feasibility studies were of excellent quality as determined by X-ray diffraction. Subsequent to the feasibility study, we designed and produced the first LabChip(TM) device specifically for protein crystallization in batch mode. It can reliably dispense and mix from a range of solution constituents into two independent growth wells. We are currently testing this design to prove its efficacy for protein crystallization optimization experiments. In the near future we will expand our design to incorporate up to 10 growth wells per LabChip(TM) device. Upon completion, additional crystallization techniques such as vapor diffusion and liquid-liquid diffusion will be accommodated. Macromolecular crystallization using microfluidic technology is envisioned as a fully automated system, which will use the 'tele-science' concept of remote operation and will be developed into a research facility for the International Space Station as well as on the ground.

  20. High and low osmolar contrast media: Who pays?

    International Nuclear Information System (INIS)

    Goethlin, J.H.

    1988-01-01

    To possibly avoid a case of contrast medium-related death in Norway every second or third year will mean a cost of many millions of dollars. It is not feasible without many patients being deprived of diagnostic possibilities. The solution is at present to use LOCM in high risk patients and small children until sufficient data (large, controlled series) can give a reliable answer to if or when LOCM should be used. (orig.)