WorldWideScience

Sample records for m13 repeat probe

  1. Chromosome-specific DNA Repeat Probes

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, Adolf; Weier, Jingly Fung; Weier, Heinz-Ulrich G.

    2006-03-16

    In research as well as in clinical applications, fluorescence in situ hybridization (FISH) has gained increasing popularity as a highly sensitive technique to study cytogenetic changes. Today, hundreds of commercially available DNA probes serve the basic needs of the biomedical research community. Widespread applications, however, are often limited by the lack of appropriately labeled, specific nucleic acid probes. We describe two approaches for an expeditious preparation of chromosome-specific DNAs and the subsequent probe labeling with reporter molecules of choice. The described techniques allow the preparation of highly specific DNA repeat probes suitable for enumeration of chromosomes in interphase cell nuclei or tissue sections. In addition, there is no need for chromosome enrichment by flow cytometry and sorting or molecular cloning. Our PCR-based method uses either bacterial artificial chromosomes or human genomic DNA as templates with {alpha}-satellite-specific primers. Here we demonstrate the production of fluorochrome-labeled DNA repeat probes specific for human chromosomes 17 and 18 in just a few days without the need for highly specialized equipment and without the limitation to only a few fluorochrome labels.

  2. Probing the central engine and environment of AGN using ARIES 1.3-m and 3.6-m telescopes

    Science.gov (United States)

    Chand, Hum; Rakshit, Suvendu; Jalan, Priyanka; Ojha, Vineet; Srianand, Raghunathan; Vivek, Mariappan; Mishra, Sapna; Omar, Amitesh; Kumar, Parveen; Joshi, Ravi; Gopal-Krishna; Kumar, Rathna

    2018-04-01

    We discuss three long term observational programmes to probe the central engine and environment of active galactic nuclei (AGN) using the recently installed ARIES 1.3-m and 3.6-m telescopes. The first programme is on the photometric reverberation mapping of low luminosity AGN by mainly using the ARIES 1.3-m telescope. The major impact of this programme other than to estimate the black hole mass will be to extend the broad line region (BLR) radius-luminosity (RBLR-LAGN) relation to the unexplored low luminosity regime, and to constrain the AGN broad line region geometry. The second programme is to use long slit spectroscopy on the ARIES 3.6-m telescope to discover new high redshift quasar pairs with angular separation less than 1-arcmin. Here, the background QSOs sight-line will be used to probe the environment of the foreground QSOs at kpc-Mpc scales. The major impact of this programme will be on the discovery of new pairs which have been missed in the SDSS survey due to fiber collision below 1-arcmin separation, and use them to understand about any excess overdensity around the QSO, any anisotropic emission of QSOs, and/or any episodic activity of QSOs. The third programme is related to spectral variability studies of the C IV broad absorption line (BAL) QSOs, based on low resolution spectroscopy using the ARIES 3.6-m telescope. Here, those most interesting cases will be monitored, where the BAL flow emerges afresh or disappears completely in the C IV trough of BAL QSOs sample as seen in SDSS multi-epoch observations. Continuous monitoring of such a sample will be important for our understanding of the nature and origin of the flow, along with their stability and dynamical evolution.

  3. Sets of RNA repeated tags and hybridization-sensitive fluorescent probes for distinct images of RNA in a living cell.

    Directory of Open Access Journals (Sweden)

    Takeshi Kubota

    Full Text Available BACKGROUND: Imaging the behavior of RNA in a living cell is a powerful means for understanding RNA functions and acquiring spatiotemporal information in a single cell. For more distinct RNA imaging in a living cell, a more effective chemical method to fluorescently label RNA is now required. In addition, development of the technology labeling with different colors for different RNA would make it easier to analyze plural RNA strands expressing in a cell. METHODOLOGY/PRINCIPAL FINDINGS: Tag technology for RNA imaging in a living cell has been developed based on the unique chemical functions of exciton-controlled hybridization-sensitive oligonucleotide (ECHO probes. Repetitions of selected 18-nucleotide RNA tags were incorporated into the mRNA 3'-UTR. Pairs with complementary ECHO probes exhibited hybridization-sensitive fluorescence emission for the mRNA expressed in a living cell. The mRNA in a nucleus was detected clearly as fluorescent puncta, and the images of the expression of two mRNAs were obtained independently and simultaneously with two orthogonal tag-probe pairs. CONCLUSIONS/SIGNIFICANCE: A compact and repeated label has been developed for RNA imaging in a living cell, based on the photochemistry of ECHO probes. The pairs of an 18-nt RNA tag and the complementary ECHO probes are highly thermostable, sequence-specifically emissive, and orthogonal to each other. The nucleotide length necessary for one tag sequence is much shorter compared with conventional tag technologies, resulting in easy preparation of the tag sequences with a larger number of repeats for more distinct RNA imaging.

  4. Cloning the human lysozyme cDNA: Inverted Alu repeat in the mRNA and in situ hybridization for macrophages and Paneth cells

    International Nuclear Information System (INIS)

    Chung, L.P.; Keshav, S.; Gordon, S.

    1988-01-01

    Lysozyme is a major secretory product of human and rodent macrophages and a useful marker for myelomonocytic cells. Based on the known human lysozyme amino acid sequence, oligonucleotides were synthesized and used as probes to screen a phorbol 12-myristate 13-acetate-treated U937 cDNA library. A full-length human lysozyme cDNA clone, pHL-2, was obtained and characterized. Sequence analysis shows that human lysozyme, like chicken lysozyme, has in 18-amino-acid-long signal peptide, but unlike the chicken lysozyme cDNA, the human lysozyme cDNA has a >1-kilobase-long 3' nontranslated sequence. Interestingly, within this 3' region, an inverted repeat of the Alu family of repetitive sequences was discovered. In RNA blot analyses, DNA probes prepared from pHL-2 can be used to detect lysozyme mRNA not only from human but also from mouse and rat. Moreover, by in situ hybridization, complementary RNA transcripts have been used as probes to detect lysozyme mRNA in mouse macrophages and Paneth cells. This human lysozyme cDNA clone is therefore likely to be a useful molecular probe for studying macrophage distribution and gene expression

  5. M13 virus based detection of bacterial infections in living hosts.

    Science.gov (United States)

    Bardhan, Neelkanth M; Ghosh, Debadyuti; Belcher, Angela M

    2014-08-01

    We report a first method for using M13 bacteriophage as a multifunctional scaffold for optically imaging bacterial infections in vivo. We demonstrate that M13 virus conjugated with hundreds of dye molecules (M13-Dye) can target and distinguish pathogenic infections of F-pili expressing and F-negative strains of E. coli. Further, in order to tune this M13-Dye complex suitable for targeting other strains of bacteria, we have used a 1-step reaction for creating an anti-bacterial antibody-M13-Dye probe. As an example, we show anti-S. aureus-M13-Dye able to target and image infections of S. aureus in living hosts, with a 3.7× increase in fluorescence over background. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Probing the possibility of a C-12/C-13 galactic abundance gradient

    International Nuclear Information System (INIS)

    Hawkins, I.

    1990-01-01

    High S/N (equal to or greater than 500) observations of interstellar CH+ with the 3.0 m telescope were performed at Lick Observatory and with the 4.0 m telescope at CTIO, of the reddened, early-type stars HD 183143, HD 24432, and HD 157038 in an effort to probe the existence of a C-12/C-13 abundance gradient in our Galaxy. Previous very high quality optical observations of interstellar CH+ toward five stars within 1 kpc of the Sun have yielded a precise weighted mean C-12/C-13 isotope ratio of 43 plus or minus 4 (1 sigma) (Hawkins, Jura, and Meyer 1985; Hawkins and Jura 1987). The isotope ratios derived toward four lines of sight in the local ISM are uniform within 12 percent. The similarity among these carbon isotope ratios determined in diffuse clouds possessing different physical conditions precludes the possibility that the CH+ molecule is suffering from isotope selective effects in these regions. The precise C-12/C-13 derivable from high quality observations of (12)CH+ and (13)CH+ provide the unique opportunity to probe the homogeneity of the ISM in a large scale and the history of nucleosynthesis in our Galaxy. Since CH+ seems to be the most sensitive probe of C-12/C-13 in the diffuse ISM, observations toward more distant stars located up to 2.5 kpc from the Sun are the best way to study the possibility of a Galactic (C-12/C-13) abundance gradient. The researcher obtained 4232 angstrom data toward all three of the stars mentioned above, 3957 angstrom data toward HD 183143 and HD 157038, and 3745 angstrom data toward HD 157038. Because of the poorer quality of the HD 24432 spectrum, and its weaker CH+ absorption lines, the satellite (13)CH+ line was not detected, and thus only a lower limit on the C-12/C-13 ratio toward this star was obtained. The results obtained from careful reduction and analysis of the data toward these stars in the Northern and Southern Hemispheres are presented

  7. Measurement of left ventricular ejection fraction with ionic sup(113m)In and a cardiac probe

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X.; Harrison, K.S.; Wagner, H.N. Jr.

    1982-09-01

    Left ventricular ejection fraction (LVEF) was measured with a cardiac probe (Nuclear Stethoscope. Bios Inc., Valhalla, New York) and sup(113m)In in 28 normal subjects and 86 patients with coronary artery disease (CAD). In 20 normal subjects sup(99m)TC-RBCs were compared with sup(113m)In, which binds to transferrin after IV injection. With sup(99m)Tc-RBCs average LVEF was 57+-7% (1 SD); with sup(113m)In, average LEVF was 55+-8% (N.S.). Sequential measurements at different times over 60 min revealed good reproducibility. Comparison of LVEF's obtained using sup(99m)Tc-RBCs with a gamma camera and cardiac probe revealed a good correlation. The correlation coefficients were 0.92 in 25 patients with CAD and 0.95 in 10 patients with LV wall motion abnormalities. The LVEF obtained using a cardiac probe and sup(113m)In increased in 28 normals from 57+-9% to 64+-13% (P<0.001) during handgrip exercise, while the LVEF decreased from 45+-9% to 41+-10% (P<0.01) in patients with acute myocardial infarction 4-7 weeks after episode, from 48+-11 to 40+-12% (P<0.001) in patients with old myocardial infarction, and from 52+-9 to 42+-9% (P<0.001) in patients with angina pectoris. The cardiac probe and sup(113m)In provide a useful alternate means of determining left ventricular dysfunction in facilities where sup(99m)Tc and a gamma camera computer system are not readily available.

  8. Measurement of left ventricular ejection fraction with ionic sup(113m)In and a cardiac probe

    International Nuclear Information System (INIS)

    Liu, X.; Harrison, K.S.; Wagner, H.N. Jr.

    1982-01-01

    Left ventricular ejection fraction (LVEF) was measured with a cardiac probe (Nuclear Stethoscope. Bios Inc., Valhalla, New York) and sup(113m)In in 28 normal subjects and 86 patients with coronary artery disease (CAD). In 20 normal subjects sup(99m)TC-RBCs were compared with sup(113m)In, which binds to transferrin after IV injection. With sup(99m)Tc-RBCs average LVEF was 57+-7% (1 SD); with sup(113m)In, average LEVF was 55+-8% (N.S.). Sequential measurements at different times over 60 min revealed good reproducibility. Comparison of LVEF's obtained using sup(99m)Tc-RBCs with a gamma camera and cardiac probe revealed a good correlation. The correlation coefficients were 0.92 in 25 patients with CAD and 0.95 in 10 patients with LV wall motion abnormalities. The LVEF obtained using a cardiac probe and sup(113m)In increased in 28 normals from 57+-9% to 64+-13% (P<0.001) during handgrip exercise, while the LVEF decreased from 45+-9% to 41+-10% (P<0.01) in patients with acute myocardial infarction 4-7 weeks after episode, from 48+-11 to 40+-12% (P<0.001) in patients with old myocardial infarction, and from 52+-9 to 42+-9% (P<0.001) in patients with angina pectoris. The cardiac probe and sup(113m)In provide a useful alternate means of determining left ventricular dysfunction in facilities where sup(99m)Tc and a gamma camera computer system are not readily available. (orig.)

  9. Probing ADAMTS13 substrate specificity using phage display.

    Directory of Open Access Journals (Sweden)

    Karl C Desch

    Full Text Available Von Willebrand factor (VWF is a large, multimeric protein that regulates hemostasis by tethering platelets to the subendothelial matrix at sites of vascular damage. The procoagulant activity of plasma VWF correlates with the length of VWF multimers, which is proteolytically controlled by the metalloprotease ADAMTS13. To probe ADAMTS13 substrate specificity, we created phage display libraries containing randomly mutated residues of a minimal ADAMTS13 substrate fragment of VWF, termed VWF73. The libraries were screened for phage particles displaying VWF73 mutant peptides that were resistant to proteolysis by ADAMTS13. These peptides exhibited the greatest mutation frequency near the ADAMTS13 scissile residues. Kinetic assays using mutant and wild-type substrates demonstrated excellent agreement between rates of cleavage for mutant phage particles and the corresponding mutant peptides. Cleavage resistance of selected mutations was tested in vivo using hydrodynamic injection of corresponding full-length expression plasmids into VWF-deficient mice. These studies confirmed the resistance to cleavage resulting from select amino acid substitutions and uncovered evidence of alternate cleavage sites and recognition by other proteases in the circulation of ADAMTS13 deficient mice. Taken together, these studies demonstrate the key role of specific amino acids residues including P3-P2' and P11', for substrate specificity and emphasize the importance in flowing blood of other ADAMTS13-VWF exosite interactions outside of VWF73.

  10. Carbon nanotubes as in vivo bacterial probes.

    Science.gov (United States)

    Bardhan, Neelkanth M; Ghosh, Debadyuti; Belcher, Angela M

    2014-09-17

    With the rise in antibiotic-resistant infections, non-invasive sensing of infectious diseases is increasingly important. Optical imaging, although safer and simpler, is less developed than other modalities such as radioimaging, due to low availability of target-specific molecular probes. Here we report carbon nanotubes (SWNTs) as bacterial probes for fluorescence imaging of pathogenic infections. We demonstrate that SWNTs functionalized using M13 bacteriophage (M13-SWNT) can distinguish between F'-positive and F'-negative bacterial strains. Moreover, through one-step modification, we attach an anti-bacterial antibody on M13-SWNT, making it easily tunable for sensing specific F'-negative bacteria. We illustrate detection of Staphylococcus aureus intramuscular infections, with ~3.4 × enhancement in fluorescence intensity over background. SWNT imaging presents lower signal spread ~0.08 × and higher signal amplification ~1.4 × , compared with conventional dyes. We show the probe offers greater ~5.7 × enhancement in imaging of S. aureus infective endocarditis. These biologically functionalized, aqueous-dispersed, actively targeted, modularly tunable SWNT probes offer new avenues for exploration of deeply buried infections.

  11. Carbon nanotubes as in vivo bacterial probes

    Science.gov (United States)

    Bardhan, Neelkanth M.; Ghosh, Debadyuti; Belcher, Angela M.

    2014-09-01

    With the rise in antibiotic-resistant infections, non-invasive sensing of infectious diseases is increasingly important. Optical imaging, although safer and simpler, is less developed than other modalities such as radioimaging, due to low availability of target-specific molecular probes. Here we report carbon nanotubes (SWNTs) as bacterial probes for fluorescence imaging of pathogenic infections. We demonstrate that SWNTs functionalized using M13 bacteriophage (M13-SWNT) can distinguish between F‧-positive and F‧-negative bacterial strains. Moreover, through one-step modification, we attach an anti-bacterial antibody on M13-SWNT, making it easily tunable for sensing specific F‧-negative bacteria. We illustrate detection of Staphylococcus aureus intramuscular infections, with ~3.4 × enhancement in fluorescence intensity over background. SWNT imaging presents lower signal spread ~0.08 × and higher signal amplification ~1.4 × , compared with conventional dyes. We show the probe offers greater ~5.7 × enhancement in imaging of S. aureus infective endocarditis. These biologically functionalized, aqueous-dispersed, actively targeted, modularly tunable SWNT probes offer new avenues for exploration of deeply buried infections.

  12. Probing ADAMTS13 Substrate Specificity using Phage Display

    Science.gov (United States)

    Desch, Karl C.; Kretz, Colin; Yee, Andrew; Gildersleeve, Robert; Metzger, Kristin; Agrawal, Nidhi; Cheng, Jane; Ginsburg, David

    2015-01-01

    Von Willebrand factor (VWF) is a large, multimeric protein that regulates hemostasis by tethering platelets to the subendothelial matrix at sites of vascular damage. The procoagulant activity of plasma VWF correlates with the length of VWF multimers, which is proteolytically controlled by the metalloprotease ADAMTS13. To probe ADAMTS13 substrate specificity, we created phage display libraries containing randomly mutated residues of a minimal ADAMTS13 substrate fragment of VWF, termed VWF73. The libraries were screened for phage particles displaying VWF73 mutant peptides that were resistant to proteolysis by ADAMTS13. These peptides exhibited the greatest mutation frequency near the ADAMTS13 scissile residues. Kinetic assays using mutant and wild-type substrates demonstrated excellent agreement between rates of cleavage for mutant phage particles and the corresponding mutant peptides. Cleavage resistance of selected mutations was tested in vivo using hydrodynamic injection of corresponding full-length expression plasmids into VWF-deficient mice. These studies confirmed the resistance to cleavage resulting from select amino acid substitutions and uncovered evidence of alternate cleavage sites and recognition by other proteases in the circulation of ADAMTS13 deficient mice. Taken together, these studies demonstrate the key role of specific amino acids residues including P3-P2’ and P11’, for substrate specificity and emphasize the importance in flowing blood of other ADAMTS13–VWF exosite interactions outside of VWF73. PMID:25849793

  13. Direct comparison of the FibroScan XL and M probes for assessment of liver fibrosis in obese and nonobese patients

    Directory of Open Access Journals (Sweden)

    Durango E

    2013-07-01

    Full Text Available Esteban Durango,1,* Christian Dietrich,1,* Helmut Karl Seitz,1 Cornelia Ursula Kunz,2 Gilles T Pomier-Layrargues,3 Andres Duarte-Rojo,4 Melanie Beaton,5 Magdy Elkhashab,6 Robert P Myers,7 Sebastian Mueller1,3 1Department of Medicine and Center for Alcohol Research, Liver Disease and Nutrition, Salem Medical Center, 2Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany; 3Liver Unit, Centre Hospitalier de l'Université de Montréal, Hôpital Saint-Luc, Montréal, Quebec, 4Toronto Western Hospital Liver Centre, Toronto, Ontario; 5Multi-Organ Transplant Unit, University of Western Ontario, London, Ontario; 6The Toronto Liver Centre, Toronto, Ontario; 7Liver Unit, Division of Gastroenterology and Hepatology, Department of Medicine, University of Calgary, Calgary, Alberta, Canada *These authors contributed equally to this researchBackground: A novel Fibroscan XL probe has recently been introduced and validated for obese patients, and has a diagnostic accuracy comparable with that of the standard M probe. The aim of this study was to analyze and understand the differences between these two probes in nonobese patients, to identify underlying causes for these differences, and to develop a practical algorithm to translate results for the XL probe to those for the M probe.Methods and results: Both probes were directly compared first in copolymer phantoms of varying stiffness (4.8, 11, and 40 kPa and then in 371 obese and nonobese patients (body mass index, range 17.2–72.4 from German (n = 129 and Canadian (n = 242 centers. Liver stiffness values for both probes correlated better in phantoms than in patients (r = 0.98 versus 0.82, P 10 kPa for F0, F1–2, F3, and F4 fibrosis, respectively significantly improved agreement between the two probes from r = 0.655 to 0.679.Conclusion: Liver stiffness can be measured in significantly more obese and nonobese patients using the XL probe than the M probe. However, the XL

  14. Studies on focal alveolar bone healing with technetium (Tc)-99m labeled methylene diphosphonate and gold-collimated cadmium telluride probe

    International Nuclear Information System (INIS)

    Tsuchimochi, M.; Hosain, F.; Engelke, W.; Zeichner, S.J.; Ruttimann, U.E.; Webber, R.L.

    1991-01-01

    The benefit of using a collimator for a miniaturized cadmium telluride probe was evaluated by monitoring the bone-healing processes for 13 weeks after the induction of small iatrogenic alveolar bone lesions in one side of the mandible in beagles. Technetium (Tc)-99m labeled methylene diphosphonate (200 to 300 MBq, 5.1 to 8.1 mCi, in a solution of 0.5 to 1 ml, intravenously) was used as a bone-seeking radiopharmaceutical. The radioactivity over the bone lesion (L) and the contralateral normal site (C) in the mandible were measured between 1.5 and 2 hours after injection of the tracer, and the activity ratio L/C served as an index of relative bone uptake. A study of six dogs revealed that the healing response to a hemispheric bone defect of 2 mm diameter in the cortical bone could not be detected by an uncollimated probe, and in a repeated study in two dogs the use of a gold collimator (5 mm in diameter, 5 mm in length) did not increase the L/C ratio significantly. A second study in six dogs with 5 mm lesions showed that although systematic trends in the time courses of the L/C ratio obtained both with and without the collimator could be demonstrated, the L/C ratio of collimated versus uncollimated measurements was significantly (p less than 0.005) increased. In three of the latter six dogs, abscesses developed after 9 weeks, leading to a second increase (p less than 0.05) of the L/C ratio with collimation compared with the noninflammation group; without collimation no significant (p greater than 0.15) difference between the two groups could be demonstrated

  15. GENETIC VARIATION IN RED RASPBERRIES (RUBUS IDAEUS L.; ROSACEAE) FROM SITES DIFFERING IN ORGANIC POLLUTANTS COMPARED WITH SYNTHETIC TANDEM REPEAT DNA PROBES

    Science.gov (United States)

    Two synthetic tandem repetitive DNA probes were used to compare genetic variation at variable-number-tandem-repeat (VNTR) loci among Rubus idaeus L. var. strigosus (Michx.) Maxim. (Rosaceae) individuals sampled at eight sites contaminated by pollutants (N = 39) and eight adjacent...

  16. Comparison of step-by-step kinematics in repeated 30m sprints in female soccer players.

    Science.gov (United States)

    van den Tillaar, Roland

    2018-01-04

    The aim of this study was to compare kinematics in repeated 30m sprints in female soccer players. Seventeen subjects performed seven 30m sprints every 30s in one session. Kinematics were measured with an infrared contact mat and laser gun, and running times with an electronic timing device. The main findings were that sprint times increased in the repeated sprint ability test. The main changes in kinematics during the repeated sprint ability test were increased contact time and decreased step frequency, while no change in step length was observed. The step velocity increased in almost each step until the 14, which occurred around 22m. After this, the velocity was stable until the last step, when it decreased. This increase in step velocity was mainly caused by the increased step length and decreased contact times. It was concluded that the fatigue induced in repeated 30m sprints in female soccer players resulted in decreased step frequency and increased contact time. Employing this approach in combination with a laser gun and infrared mat for 30m makes it very easy to analyse running kinematics in repeated sprints in training. This extra information gives the athlete, coach and sports scientist the opportunity to give more detailed feedback and help to target these changes in kinematics better to enhance repeated sprint performance.

  17. Triage of Women with Low-Grade Cervical Lesions - HPV mRNA Testing versus Repeat Cytology

    Science.gov (United States)

    Sørbye, Sveinung Wergeland; Arbyn, Marc; Fismen, Silje; Gutteberg, Tore Jarl; Mortensen, Elin Synnøve

    2011-01-01

    Background In Norway, women with low-grade squamous intraepithelial lesions (LSIL) are followed up after six months in order to decide whether they should undergo further follow-up or be referred back to the screening interval of three years. A high specificity and positive predictive value (PPV) of the triage test is important to avoid unnecessary diagnostic and therapeutic procedures. Materials and Methods At the University Hospital of North Norway, repeat cytology and the HPV mRNA test PreTect HPV-Proofer, detecting E6/E7 mRNA from HPV types 16, 18, 31, 33 and 45, are used in triage of women with ASC-US and LSIL. In this study, women with LSIL cytology in the period 2005–2008 were included (n = 522). Two triage methods were evaluated in two separate groups: repeat cytology only (n = 225) and HPV mRNA testing in addition to repeat cytology (n = 297). Histologically confirmed cervical intraepithelial neoplasia of grade 2 or worse (CIN2+) was used as the study endpoint. Results Of 522 women with LSIL, 207 had biopsies and 125 of them had CIN2+. The sensitivity and specificity of repeat cytology (ASC-US or worse) were 85.7% (95% confidence interval (CI): 72.1, 92.2) and 54.4 % (95% CI: 46.9, 61.9), respectively. The sensitivity and specificity of the HPV mRNA test were 94.2% (95% CI: 88.7, 99.7) and 86.0% (95% CI: 81.5, 90.5), respectively. The PPV of repeat cytology was 38.4% (95% CI: 29.9, 46.9) compared to 67.0% (95% CI: 57.7, 76.4) of the HPV mRNA test. Conclusion HPV mRNA testing was more sensitive and specific than repeat cytology in triage of women with LSIL cytology. In addition, the HPV mRNA test showed higher PPV. These data indicate that the HPV mRNA test is a better triage test for women with LSIL than repeat cytology. PMID:21918682

  18. Technetium-99m labeled antisense probes uptake in vascular smooth muscle cells

    International Nuclear Information System (INIS)

    Zhang, Y.X.; Qin, G.M.; An, R.; Cao, G.X.; Cao, W.; Gao, Z.R.

    2002-01-01

    ex-cellular concentration between 0.05μg to 1.5μg. The SMC showed higher uptake for c-myc probe than bcl-2 probe. The normalized uptake per million cells was higher for the antisense than for the sense c-myc probe, it was also higher for the SMC in log rather than in plateau phase. Percentage uptake of bcl-2 antisense probe by the SMC was slightly lower in log phase than in plateau phase. Conclusion: These data suggested that 99m Tc- MAG 3 -DNA should be considered further as an early specific technique in noninvasive diagnosis of arteriosclerotic lesions. Increased uptake of c-myc antisense probe accompanied with diminished uptake of bcl-2 antisense probe may suggested a lesion of atherosclerosis at an early stage

  19. Sandwich nucleic acid hybridization: a method with a universally usable labeled probe for various specific tests

    International Nuclear Information System (INIS)

    Wolf, H.; Leser, U.; Haus, M.; Gu, S.Y.; Pathmanathan, R.

    1986-01-01

    The use of recombinant m13 phages as hybridization probes offers a considerable advantage over the commonly used recombinant plasmids as the preparation of the DNA probe is very simple and it can easily be labeled directly, e.g. with isotopes with long half-life like 125 I and used for hybridization. However, as the application of nucleic acid hybridization for diagnostic and epidemiological purposes becomes almost unavoidable, the logistic problems of keeping numerous individually labeled hybridization probes increase considerably and may reach prohibitory levels in less well-equipped laboratories. In a new sandwich technique, the first step involves hybridization with an unlabeled recombinant m13 DNA carrying an insert of the desired specificity. In a second step a universally usable labeled probe directed against the m13 part of the recombinant phage DNA is applied. This reduces considerably the problem of preparing and keeping multiple labeled probes in stock. (Auth.)

  20. Probing non-perturbative effects in M-theory

    International Nuclear Information System (INIS)

    Hatsuda, Yasuyuki; Okuyama, Kazumi

    2014-07-01

    The AdS/CFT correspondence enables us to probe M-theory on various backgrounds from the corresponding dual gauge theories. Here we investigate in detail a three-dimensional U(N) N=4 super Yang-Mills theory coupled to one adjoint hypermultiplet and N f fundamental hypermultiplets, which is large N dual to M-theory on AdS 4 x S 7 /Z N f . Using the localization and the Fermi-gas formulation, we explore non-perturbative corrections to the partition function. As in the ABJM theory, we find that there exists a non-trivial pole cancellation mechanism, which guarantees the theory to be well-defined, between worldsheet instantons and membrane instantons for all rational (in particular, physical or integral) values of N f .

  1. Genetic variations of the A13/A14 repeat located within the EGFR 3′ untranslated region have no oncogenic effect in patients with colorectal cancer

    International Nuclear Information System (INIS)

    Sarafan-Vasseur, Nasrin; Latouche, Jean-Baptiste; Frebourg, Thierry; Sesboüé, Richard; Sefrioui, David; Tougeron, David; Lamy, Aude; Blanchard, France; Le Pessot, Florence; Di Fiore, Frédéric; Michel, Pierre; Bézieau, Stéphane

    2013-01-01

    The EGFR 3′ untranslated region (UTR) harbors a polyadenine repeat which is polymorphic (A13/A14) and undergoes somatic deletions in microsatellite instability (MSI) colorectal cancer (CRC). These mutations could be oncogenic in colorectal tissue since they were shown to result into increased EGFR mRNA stability in CRC cell lines. First, we determined in a case control study including 429 CRC patients corresponding to different groups selected or not on age of tumor onset and/or familial history and/or MSI, whether or not, the germline EGFR A13/A14 polymorphism constitutes a genetic risk factor for CRC; second, we investigated the frequency of somatic mutations of this repeat in 179 CRC and their impact on EGFR expression. No statistically significant difference in allelic frequencies of the EGFR polyA repeat polymorphism was observed between CRC patients and controls. Somatic mutations affecting the EGFR 3′UTR polyA tract were detected in 47/80 (58.8%) MSI CRC versus 0/99 microsatellite stable (MSS) tumors. Comparative analysis in 21 CRC samples of EGFR expression, between tumor and non malignant tissues, using two independent methods showed that somatic mutations of the EGFR polyA repeat did not result into an EGFR mRNA increase. Germline and somatic genetic variations occurring within the EGFR 3′ UTR polyA tract have no impact on CRC genetic risk and EGFR expression, respectively. Genotyping of the EGFR polyA tract has no clinical utility to identify patients with a high risk for CRC or patients who could benefit from anti-EGFR antibodies

  2. Chromosome breakage in Prader-Willi and Angelman syndrome deletions may involve recombination between a repeat at the proximal and distal breakpoints

    Energy Technology Data Exchange (ETDEWEB)

    Amos-Landgraf J.; Nicholls, R.D. [Case Western Reserve Univ., Cleveland, OH (United States); Gottlieb, W. [Univ. of Florida, Gainesville, FL (United States)] [and others

    1994-09-01

    Prader-Willi (PWS) and Angelman (AS) syndromes most commonly arise from large deletions of 15q11-q13. Deletions in PWS are paternal in origin, while those in AS are maternal in origin, clearly demonstrating genomic imprinting in these clinically distinct neurobehavioural disorders. In at least 90% of PWS and AS deletion patients, the same 4 Mb region within 15q11-q13 is deleted with breakpoints clustering in single YAC clones at the proximal and distal ends. To study the mechanism of chromosome breakage in PWS and AS, we have previously isolated 25 independent clones from these three YACs using Alu-vector PCR. Four clones were selected that appear to detect a low copy repeat that is located in the proximal and distal breakpoint regions of chromosome 15q11-q13. Three clones detect the same 4 HindIII bands in genomic DNA, all from 15q11-q13, with differing intensities for the probes located at the proximal or distal breakpoints region, respectively. This suggests that these probes detect related members of a low-copy repeat at either location. Moreover, the 254RL2 probe detects a novel HindIII band in two unrelated PWS deletion patients, suggesting that this may represent a breakpoint fragment, with recombination occurring within a similar interval in both patients. A fourth clone, 318RL3 detects 5 bands in HindIII-digested genomic DNA, all from 15q11-q13. This YAC endclone itself is not deleted in PWS and AS deletion patients, as seen by an invariant strong band. Two other strong bands are variably intact or deleted in different PWS or AS deletion patients, suggesting a relationship of this sequence to the breakpoints. Moreover, PCR using 318RL3 primers from the distal 93C9 YAC led to the isolation of a related clone with 96% identity, demonstrating the existence of a low-copy repeat with members close to the proximal and distal breakpoints. Taken together, our data suggest a complex, low-copy repeat with members at both the proximal and distal boundaries.

  3. [Comparison of the M and XL FibroScan(®) probes to estimate liver stiffness by transient elastography].

    Science.gov (United States)

    Herrero, José Ignacio; Iñarrairaegui, Mercedes; D'Avola, Delia; Sangro, Bruno; Prieto, Jesús; Quiroga, Jorge

    2014-04-01

    The FibroScan(®) XL probe has been specifically designed for obese patients to measure liver stiffness by transient elastography, but it has not been well tested in non-obese patients. The aim of this study was to compare the M and XL FibroScan(®) probes in a series of unselected obese (body mass index above 30 kg/m(2)) and non-obese patients with chronic liver disease. Two hundred and fifty-four patients underwent a transient elastography examination with both the M and XL probes. The results obtained with the two probes were compared in the whole series and in obese (n=82) and non-obese (n=167) patients separately. The reliability of the examinations was assessed using the criteria defined by Castéra et al. The proportion of reliable exams was significantly higher when the XL probe was used (83% versus 73%; P=.001). This significance was maintained in the group of obese patients (82% versus 55%; P<.001), but not in the non-obese patients (84% versus 83%). Despite a high correlation between the stiffness values obtained with the two probes (R=.897; P<.001), and a high concordance in the estimation of fibrosis obtained with the two probes (Cronbach's alpha value: 0.932), the liver stiffness values obtained with the XL probe were significantly lower than those obtained with the M probe, both in the whole series (9.5 ± 9.1 kPa versus 11.3 ± 12.6 kPa; P<0.001) and in the obese and non-obese groups. In conclusion, transient elastography with the XL probe allows a higher proportion of reliable examinations in obese patients but not in non-obese patients. Stiffness values were lower with the XL probe than with the M probe. Copyright © 2013 Elsevier España, S.L. and AEEH y AEG. All rights reserved.

  4. In situ optical sequencing and structure analysis of a trinucleotide repeat genome region by localization microscopy after specific COMBO-FISH nano-probing

    Science.gov (United States)

    Stuhlmüller, M.; Schwarz-Finsterle, J.; Fey, E.; Lux, J.; Bach, M.; Cremer, C.; Hinderhofer, K.; Hausmann, M.; Hildenbrand, G.

    2015-10-01

    Trinucleotide repeat expansions (like (CGG)n) of chromatin in the genome of cell nuclei can cause neurological disorders such as for example the Fragile-X syndrome. Until now the mechanisms are not clearly understood as to how these expansions develop during cell proliferation. Therefore in situ investigations of chromatin structures on the nanoscale are required to better understand supra-molecular mechanisms on the single cell level. By super-resolution localization microscopy (Spectral Position Determination Microscopy; SPDM) in combination with nano-probing using COMBO-FISH (COMBinatorial Oligonucleotide FISH), novel insights into the nano-architecture of the genome will become possible. The native spatial structure of trinucleotide repeat expansion genome regions was analysed and optical sequencing of repetitive units was performed within 3D-conserved nuclei using SPDM after COMBO-FISH. We analysed a (CGG)n-expansion region inside the 5' untranslated region of the FMR1 gene. The number of CGG repeats for a full mutation causing the Fragile-X syndrome was found and also verified by Southern blot. The FMR1 promotor region was similarly condensed like a centromeric region whereas the arrangement of the probes labelling the expansion region seemed to indicate a loop-like nano-structure. These results for the first time demonstrate that in situ chromatin structure measurements on the nanoscale are feasible. Due to further methodological progress it will become possible to estimate the state of trinucleotide repeat mutations in detail and to determine the associated chromatin strand structural changes on the single cell level. In general, the application of the described approach to any genome region will lead to new insights into genome nano-architecture and open new avenues for understanding mechanisms and their relevance in the development of heredity diseases.

  5. Magnetic probe measurement of MHD behaviors in the TRIAM-1M tokamak

    International Nuclear Information System (INIS)

    Yanagisawa, Michihiko; Kawasaki, Shoji; Moriyama, Shin-ichi; Nagao, Akihiro; Nakamura, Kazuo; Hiraki, Naoji; Nakamura, Yukio; Itoh, Satoshi; Jotaki, Eriko.

    1988-01-01

    MHD behavior and following disruption were observed at low-q discharge and high-density discharge in TRIAM-1A. It was observed by magnetic probe, that interaction between m=3/n=2 and m=2/n=1 modes in low-q discharge, and growth of m=2/n=1 in high discharge drive to disruption. (J.P.N)

  6. M13 Bacteriophage Based Protein Sensors

    Science.gov (United States)

    Lee, Ju Hun

    Despite significant progress in biotechnology and biosensing, early detection and disease diagnosis remains a critical issue for improving patient survival rates and well-being. Many of the typical detection schemes currently used possess issues such as low sensitivity and accuracy and are also time consuming to run and expensive. In addition, multiplexed detection remains difficult to achieve. Therefore, developing advanced approaches for reliable, simple, quantitative analysis of multiple markers in solution that also are highly sensitive are still in demand. In recent years, much of the research has primarily focused on improving two key components of biosensors: the bio-recognition agent (bio-receptor) and the transducer. Particular bio-receptors that have been used include antibodies, aptamers, molecular imprinted polymers, and small affinity peptides. In terms of transducing agents, nanomaterials have been considered as attractive candidates due to their inherent nanoscale size, durability and unique chemical and physical properties. The key focus of this thesis is the design of a protein detection and identification system that is based on chemically engineered M13 bacteriophage coupled with nanomaterials. The first chapter provides an introduction of biosensors and M13 bacteriophage in general, where the advantages of each are provided. In chapter 2, an efficient and enzyme-free sensor is demonstrated from modified M13 bacteriophage to generate highly sensitive colorimetric signals from gold nanocrystals. In chapter 3, DNA conjugated M13 were used to enable facile and rapid detection of antigens in solution that also provides modalities for identification. Lastly, high DNA loadings per phage was achieved via hydrozone chemistry and these were applied in conjunction with Raman active DNA-gold/silver core/shell nanoparticles toward highly sensitive SERS sensing.

  7. The natural abundance of 13C with different agricultural management by NIRS with fibre optic probe technology.

    Science.gov (United States)

    Fuentes, Mariela; González-Martín, Inmaculada; Hernández-Hierro, Jose Miguel; Hidalgo, Claudia; Govaerts, Bram; Etchevers, Jorge; Sayre, Ken D; Dendooven, Luc

    2009-06-30

    In the present study the natural abundance of (13)C is quantified in agricultural soils in Mexico which have been submitted to different agronomic practices, zero and conventional tillage, retention of crop residues (with and without) and rotation of crops (wheat and maize) for 17 years, which have influenced the physical, chemical and biological characteristics of the soil. The natural abundance of C13 is quantified by near infrared spectra (NIRS) with a remote reflectance fibre optic probe, applying the probe directly to the soil samples. Discriminate partial least squares analysis of the near infrared spectra allowed to classify soils with and without residues, regardless of the type of tillage or rotation systems used with a prediction rate of 90% in the internal validation and 94% in the external validation. The NIRS calibration model using a modified partial least squares regression allowed to determine the delta(13)C in soils with or without residues, with multiple correlation coefficients 0.81 and standard error prediction 0.5 per thousand in soils with residues and 0.92 and 0.2 per thousand in soils without residues. The ratio performance deviation for the quantification of delta(13)C in soil was 2.5 in soil with residues and 3.8 without residues. This indicated that the model was adequate to determine the delta(13)C of unknown soils in the -16.2 per thousand to -20.4 per thousand range. The development of the NIR calibration permits analytic determinations of the values of delta(13)C in unknown agricultural soils in less time, employing a non-destructive method, by the application of the fibre optic probe of remote reflectance to the soil sample.

  8. Distribution of mating-type alleles and M13 PCR markers in the black leaf spot fungus Mycosphaerella fijiensis of bananas in Brazil.

    Science.gov (United States)

    Queiroz, C B; Miranda, E C; Hanada, R E; Sousa, N R; Gasparotto, L; Soares, M A; Silva, G F

    2013-02-08

    The fungus Mycosphaerella fijiensis is the causative agent of black sigatoka, which is one of the most destructive diseases of banana plants. Infection with this pathogen results in underdeveloped fruit, with no commercial value. We analyzed the distribution of the M. fijiensis mating-type system and its genetic variability using M13 phage DNA markers. We found a 1:1 distribution of mating-type alleles, indicating MAT1-1 and MAT1-2 idiomorphs. A polymorphism analysis using three different primers for M13 markers showed that only the M13 minisatellite primers generated polymorphic products. We then utilized this polymorphism to characterize 40 isolates from various Brazilian states. The largest genetic distances were found between isolates from the same location and between isolates from different parts of the country. Therefore, there was no correlation between the genetic similarity and the geographic origin of the isolates. The M13 marker was used to generate genetic fingerprints for five isolates; these fingerprints were compared with the band profiles obtained from inter-simple sequence repeat (UBC861) and inter-retrotransposon amplified polymorphism analyses. We found that the M13 marker was more effective than the other two markers for differentiating these isolates.

  9. Study on a 4-Week Recovery Test of Sweet Bee Venom after a 13-Week, Repeated, Intramuscular Dose Toxicity Test in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Chungsan Lim

    2014-06-01

    Full Text Available Objectives:This study was performed to check for reversibility in the changes induced by a 13-week, repeated, dose toxicity test of Sweet Bee Venom (SBV in Sprague-Dawley (SD rats. Methods:Fifteen male and 15 female SD rats were treated with 0.28 mg/kg of SBV (high-dosage group and the same numbers of male and female SD rats were treated with 0.2 mL/kg of normal saline (control group for 13 weeks. We selected five male and five female SD rats from the high-dosage group and the same numbers of male and female SD rats from the control group, and we observed these rats for four weeks. We conducted body-weight measurements, ophthalmic examinations, urinalyses and hematology, biochemistry, histology tests. Results:(1 Hyperemia and movement disorder were observed in the 13-week, repeated, dose toxicity test, but these symptoms were not observed during the recovery period. (2 The rats in the high-dose group showed no significant changes in weight compared to the control group. (3 No significant differences in the ophthalmic parameters, urine analyses, complete blood cell counts (CBCs, and biochemistry were observed among the recovery groups. (4 No changes in organ weights were observed during the recovery period. (5 Histological examination of the thigh muscle indicated cell infiltration, inflammation, degeneration, necrosis of muscle fiber, and fibrosis during the treatment period, but these changes were not observed during the recovery period. The fatty liver change that was observed during the toxicity test was not observed during the recovery period. No other organ abnormalities were observed. Conclusion:The changes that occurred during the 13-week, repeated, dose toxicity test are reversible, and SBV can be safely used as a treatment modality.

  10. Solid state CP/MAS 13C n.m.r. analysis of particle size and density fractions of soil incubated with uniformly labelled 13C-glucose

    International Nuclear Information System (INIS)

    Baldock, J.A.; Oades, J.M.

    1990-01-01

    A soil incubated for 34 days in the absence (control) and presence (treated) of uniformly labelled 13 C-glucose was dispersed using an ultrasonic probe and fractionated by sedimentation in water and a polytungstate solution of density 2.0 Mg m -3 . Solid state CP/MAS 13 C n.m.r. (cross polarization/magic angle spinning 13 C nuclear magnetic resonance) spectroscopy was used to characterize the chemical structure of the native soil organic carbon and the residual substrate carbon in the fractions of the control and treated soils. To obtain quantitative results it was essential to determine the spin lattice relaxation time in a rotating frame of the individual carbon types in the spectra as the relaxation behaviour of the native organic material in the clay fraction was different from that of the residual substrate carbon. The residual substrate carbon was found to accumulate in predominantly alkyl and O-alkyl structures in both fractions. However, significant amounts of acetal and carboxyl carbon were also observed in the clay fraction. Little if any aromatic or phenolic carbon was synthesized by the soil microorganisms utilizing substrate carbon. Dipolar dephasing CP/MAS 13 C n.m.r. experiments were also performed and allowed the proportion of each type of carbon which was protonated and nonprotonated to be estimated. Essentially all of the O-alkyl and acetal carbon, 25-40% of the aromatic carbon and 66-80% of the alkyl carbon was protonated in the fractions isolated from the treated soil. 24 refs., 4 figs., 2 tabs

  11. Monovacancy paramagnetism in neutron-irradiated graphite probed by 13C NMR.

    Science.gov (United States)

    Zhang, Z T; Xu, C; Dmytriieva, D; Molatta, S; Wosnitza, J; Wang, Y T; Helm, M; Zhou, Shengqiang; Kühne, H

    2017-10-20

    We report on the magnetic properties of monovacancy defects in neutron-irradiated graphite, probed by 13 C nuclear magnetic resonance spectroscopy. The bulk paramagnetism of the defect moments is revealed by the temperature dependence of the NMR frequency shift and spectral linewidth, both of which follow a Curie behavior, in agreement with measurements of the macroscopic magnetization. Compared to pristine graphite, the fluctuating hyperfine fields generated by the defect moments lead to an enhancement of the 13 C nuclear spin-lattice relaxation rate [Formula: see text] by about two orders of magnitude. With an applied magnetic field of 7.1 T, the temperature dependence of [Formula: see text] below about 10 K can well be described by a thermally activated form, [Formula: see text], yielding a singular Zeeman energy of ([Formula: see text]) meV, in excellent agreement with the sole presence of polarized, non-interacting defect moments.

  12. Three-dimensional evaluation of compositional and structural changes in cycled LiNi1/3Co1/3Mn1/3O2 by atom probe tomography

    Science.gov (United States)

    Lee, Ji Yeong; Kim, Ji Yoon; Cho, Hae In; Lee, Chi Ho; Kim, Han Sung; Lee, Sang Uck; Prosa, Ty J.; Larson, David J.; Yu, Tae Hwan; Ahn, Jae-Pyoung

    2018-03-01

    Accelerated capacity fading of LiNi1/3Co1/3Mn1/3O2 (NCM111) electrode by the chemical migration of lithium (Li) or transition metals (TMs), and surface reconstruction in the surface during electrochemical cycling were evaluated by correlative analysis of atom probe tomography (APT) and transmission electron microscopy (TEM). The cycled NCM111 showed a lack of Li at surface which provides the driving force for long-range Ni migration toward surface. A schematic model for phase transformation and the kinetics of TM migration within the layered structure by density functional theory (DFT) calculations was proposed. This study provides insights into capacity loss and voltage fade upon electrochemical charge-discharge process of NCM111 by measuring the variation of Li composition away from the surface.

  13. Molecularly imprinted fluorescent probe based on FRET for selective and sensitive detection of doxorubicin

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhifeng, E-mail: 897061147@qq.com [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China); Deng, Peihong; Li, Junhua [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China); Xu, Li [Department of Applied Chemistry, College of Materials and Energy, South China Agricultural University, Guangzhou 510642 (China); Tang, Siping [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China)

    2017-04-15

    Highlights: • FRET-based molecularly imprinted probe for detection of doxorubicin was prepared. • The detection limit of the probe was 13.8 nM for doxorubicin. • The FRET-based probe had a higher selectivity for the template than ordinary MIMs. - Abstract: In this work, a new type of fluorescent probe for detection of doxorubicin has been constructed by the combined use of fluorescence resonance energy transfer (FRET) technology and molecular imprinting technique (MIT). Using doxorubicin as the template, the molecularly imprinted polymer thin layer was fabricated on the surfaces of carbon dot (CD) modified silica by sol-gel polymerization. The excitation energy of the fluorescent donor (CDs) could be transferred to the fluorescent acceptor (doxorubicin). The FRET based fluorescent probe demonstrated high sensitivity and selectivity for doxorubicin. The detection limit was 13.8 nM. The fluorescent probe was successfully applied for detecting doxorubicin in doxorubicin-spiked plasmas with a recovery of 96.8–103.8%, a relative standard deviation (RSD) of 1.3–2.8%. The strategy for construction of FRET-based molecularly imprinted materials developed in this work is very promising for analytical applications.

  14. Probing the electronic structure of M-graphene oxide (M = Ni, Co, NiCo) catalysts for hydrolytic dehydrogenation of ammonia borane

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Binhua; Liu, Jinyin; Zhou, Litao [Soochow University-Western University Centre for Synchrotron Radiation Research, Institute of Functional Nano and Soft Material (FUNSOM) and Collaborative Innovation Center of Suzhou Nano Science & Technology, Soochow University, Suzhou 215123 (China); Long, Dan, E-mail: legend_long@aliyun.com [Department of Radiology, Zhejiang Cancer Hospital, Hangzhou 310022 (China); Feng, Kun; Sun, Xuhui [Soochow University-Western University Centre for Synchrotron Radiation Research, Institute of Functional Nano and Soft Material (FUNSOM) and Collaborative Innovation Center of Suzhou Nano Science & Technology, Soochow University, Suzhou 215123 (China); Zhong, Jun, E-mail: jzhong@suda.edu.cn [Soochow University-Western University Centre for Synchrotron Radiation Research, Institute of Functional Nano and Soft Material (FUNSOM) and Collaborative Innovation Center of Suzhou Nano Science & Technology, Soochow University, Suzhou 215123 (China)

    2016-01-30

    Graphical abstract: An interaction between metal and graphene oxide was probed to enhance the hydrolysis efficiency of ammonia borane. - Highlights: • Various metal elements (M = Ni, Co, NiCo) were dispersed on graphene oxide (GO) for the hydrolysis of ammonia borane (AB). • The electronic structure of the hybrids has been probed by scanning transmission X-ray microscopy (STXM). • An interfacial interaction between metal and GO was observed which could be related to the hydrolysis performance. • The results provide new insight into the enhanced performance of the M-GO hybrids. - Abstract: Various metal elements (M = Ni, Co, NiCo) were dispersed on graphene oxide (GO) to form the M-GO hybrids by a facile way. The hybrids showed good catalytic activities in the hydrolytic dehydrogenation of ammonia borane (AB, NH{sub 3}BH{sub 3}), which were significantly enhanced when compared to the metal nanoparticles or GO alone. The electronic structure of the hybrids has been probed by scanning transmission X-ray microscopy (STXM). The distribution of metal elements was clearly imaged with identical electronic structure. Moreover, an interfacial interaction between metal and GO was observed with the peak intensity proportional to the catalytic performance in the hydrolysis of AB. The results provide new insight into the enhanced performance of the M-GO hybrids and may help for the design of advanced catalysts.

  15. Monovacancy paramagnetism in neutron-irradiated graphite probed by 13C NMR.

    Science.gov (United States)

    Zhang, Zhi Tao; Xu, C; Dmytriieva, Daryna; Molatta, Sebastian; Wosnitza, J; Wang, Y T; Helm, Manfred; Zhou, Shengqiang; Kuehne, Hannes

    2017-09-18

    We report on the magnetic properties of monovacancy defects in neutron-irradiated graphite, probed by $^{13}$C nuclear magnetic resonance spectroscopy. The bulk paramagnetism of the defect moments is revealed by the temperature dependence of the NMR frequency shift and spectral linewidth, both of which follow a Curie behavior, in agreement with measurements of the macroscopic magnetization. Compared to pristine graphite, the fluctuating hyperfine fields generated by the defect moments lead to an enhancement of the $^{13}$C nuclear spin-lattice relaxation rate $1/T_{1}$ by about two orders of magnitude. With an applied magnetic field of 7.1 T, the temperature dependence of $1/T_{1}$ below about 10 K can well be described by a thermally activated form, $1/T_{1}\\propto\\exp(-\\Delta/k_{B}T)$, yielding a singular Zeeman energy of ($0.41\\pm0.01$) meV, in excellent agreement with the sole presence of polarized, non-interacting defect moments. © 2017 IOP Publishing Ltd.

  16. In situ detection of tandem DNA repeat length

    Energy Technology Data Exchange (ETDEWEB)

    Yaar, R.; Szafranski, P.; Cantor, C.R.; Smith, C.L. [Boston Univ., MA (United States)

    1996-11-01

    A simple method for scoring short tandem DNA repeats is presented. An oligonucleotide target, containing tandem repeats embedded in a unique sequence, was hybridized to a set of complementary probes, containing tandem repeats of known lengths. Single-stranded loop structures formed on duplexes containing a mismatched (different) number of tandem repeats. No loop structure formed on duplexes containing a matched (identical) number of tandem repeats. The matched and mismatched loop structures were enzymatically distinguished and differentially labeled by treatment with S1 nuclease and the Klenow fragment of DNA polymerase. 7 refs., 4 figs.

  17. $^{204m}$Pb: A new Probe for TDPAC Experiments in Biology Complementing the Well Established Probes $^{111}$Cd and $^{199m}$Hg

    CERN Multimedia

    2002-01-01

    The short-lived nuclear probes $\\,^{111m}$Cd( t$_{1/2}$ = 49 min) , $^{199m}$Hg ( t$_{1/2}$ = 43 min) , and $^{204m}$Pb( t$_{1/2}$ = 43 min) supplied by ISOLDE are used to study the interaction of metals with biological macromolecules like, e.g., DNA and proteins. The structure and dynamics of metal sites in biomolecules are important in determining the functional efficiency of these macromolecules. Many life processes are based on such interactions. In order to study those metal sites close to physiological conditions a highly sensitive spectroscopic method is required, like Time Differential Perturbed Angular Correlation (TDPAC). Here, a radioactive atom is placed at the site of interest and by correlating the emitted $\\gamma$-quanta in space and on a nanosecond time scale local structural information is provided via the Nuclear Quadrupole Interaction. These investigations will allow a deeper insight into the adaptivity and rigidity of metal sites in the blue copper proteins (electron transfer proteins), th...

  18. Non-radioactive detection of trinucleotide repeat size variability.

    Science.gov (United States)

    Tomé, Stéphanie; Nicole, Annie; Gomes-Pereira, Mario; Gourdon, Genevieve

    2014-03-06

    Many human diseases are associated with the abnormal expansion of unstable trinucleotide repeat sequences. The mechanisms of trinucleotide repeat size mutation have not been fully dissected, and their understanding must be grounded on the detailed analysis of repeat size distributions in human tissues and animal models. Small-pool PCR (SP-PCR) is a robust, highly sensitive and efficient PCR-based approach to assess the levels of repeat size variation, providing both quantitative and qualitative data. The method relies on the amplification of a very low number of DNA molecules, through sucessive dilution of a stock genomic DNA solution. Radioactive Southern blot hybridization is sensitive enough to detect SP-PCR products derived from single template molecules, separated by agarose gel electrophoresis and transferred onto DNA membranes. We describe a variation of the detection method that uses digoxigenin-labelled locked nucleic acid probes. This protocol keeps the sensitivity of the original method, while eliminating the health risks associated with the manipulation of radiolabelled probes, and the burden associated with their regulation, manipulation and waste disposal.

  19. Repeatability of regional myocardial blood flow calculation in 82Rb PET imaging

    International Nuclear Information System (INIS)

    Knešaurek, Karin; Machac, Josef; Zhang, Zhuangyu

    2009-01-01

    We evaluated the repeatability of the calculation of myocardial blood flow (MBF) at rest and pharmacological stress, and calculated the coronary flow reserve (CFR) utilizing 82 Rb PET imaging. The aim of the research was to prove high repeatability for global MBF and CFR values and good repeatability for regional MBF and CFR values. The results will have significant impact on cardiac PET imaging in terms of making it more affordable and increasing its use. 12 normal volunteers were imaged at rest and during pharmacological stress, with 2220 MBq of 82 Rb each. A GE Advance PET system was used to acquire dynamic 50-frame studies. MBF was calculated with a 2-compartmental model using a modified PMOD program (PMOD; University Hospital Zurich, Zurich, Switzerland). Two differential equations, describing a 2-compartmental model, were solved by numerical integration and using Levenberg-Marquardt's method for fitting data. The PMOD program defines 16 standard segments and calculates myocardial flow for each segment, as well as average septal, anterior, lateral, inferior and global flow. Repeatability was evaluated according to the method of Bland and Altman. Global rest and stress MBF, as well as global CFR, showed very good repeatability. No significant differences were found between the paired resting global MBF (0.63 ± 0.13 vs. 0.64 ± 0.13 mL/min/g; mean difference, -1.0% ± 2.6%) and the stress global MBF (1.37 ± 0.23 vs. 1.37 ± 0.24; mean difference, 0.1% ± 2.3%). Global CFR was highly reproducible (2.25 ± 0.56 vs. 2.22 ± 0.54, P = not statistically significant; mean difference, 1.3% ± 14.3%). Repeatability coefficients for global rest MBF were 0.033 (5.2%) and stress MBF 0.062 (4.5%) mL/min/g. Regional rest and stress MBF and CFR have shown good reproducibility. The average per sector repeatability coefficients for rest MBF were 0.056 (8.5%) and stress MBF 0.089 (6.3%) mL/min/g, and average repeatability coefficient for CFR was 0.25 (10.6%). The results

  20. A shrouded aerosol sampling probe: Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    McFarland, A.R.; Ortiz, C.A.; Moore, M.E.; DeOtte, R.E. Jr.; Somasundaram, S.

    1988-08-01

    A new device has been developed for sampling aerosol particles from moving air streams--a shrouded probe. In the design reported herein, a 30 mm diameter sampling probe is located concentrically within a 105 mm diameter cylindrically-shaped shroud. The flow rate through the sampling probe is a constant value of 170 l/min. The dynamic pressure of the external air stream forces flow through the region between the shroud and the internal probe. The velocity of the main air stream, U/sub o/, is reduced in the shroud such that the velocity just upstream of the probe, U/sub s/, is 0.40 that of U/sub o/. By reducing the main air stream velocity, the aerosol losses on the internal walls of the probe inlet are considerably reduced. For a typical isokinetic probe sampling at 170 l/min in an air stream with a velocity of 14 m/s, the wall losses of 10 μm aerodynamic diameter particles are 39% of the total aspirated aerosol; whereas, the wall losses in the shrouded probe are 13%. Also, by reducing the velocity of the air stream in the shroud, anisokinetic effects can be substantially reduced. Wind tunnel experiments with 10 μm diameter particles over the range of free stream velocities of 2.0 to 14 m/s show the transmission ratio (ratio of aerosol transmitted through the probe to aerosol concentration in the free stream) to be within the range of 0.93 to 1.11. These data are for a constant flow rate of 170 l/min through the probe. 19 refs., 7 figs

  1. Assessment of the LV-C2 Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Antonio, Ernest J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Flaherty, Julia E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-01

    This document reports on a series of tests conducted to assess the proposed air sampling location for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) C2V (LV-C2) exhaust stack with respect to the applicable criteria regarding the placement of an air sampling probe. Federal regulations require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The tests were conducted on the LV-C2 scale model system. Based on the scale model tests, the location proposed for the air sampling probe in the scale model stack meets the requirements of the ANSI/HPS N13.1-1999 standard for velocity uniformity, flow angle, gas tracer and particle tracer uniformity. Additional velocity uniformity and flow angle tests on the actual stack will be necessary during cold startup to confirm the validity of the scale model results in representing the actual stack.

  2. Immediate-early gene response to repeated immobilization: Fos protein and arc mRNA levels appear to be less sensitive than c-fos mRNA to adaptation.

    Science.gov (United States)

    Ons, Sheila; Rotllant, David; Marín-Blasco, Ignacio J; Armario, Antonio

    2010-06-01

    Stress exposure resulted in brain induction of immediate-early genes (IEGs), considered as markers of neuronal activation. Upon repeated exposure to the same stressor, reduction of IEG response (adaptation) has been often observed, but there are important discrepancies in literature that may be in part related to the particular IEG and methodology used. We studied the differential pattern of adaptation of the IEGs c-fos and arc (activity-regulated cytoskeleton-associated protein) after repeated exposure to a severe stressor: immobilization on wooden boards (IMO). Rats repeatedly exposed to IMO showed reduced c-fos mRNA levels in response to acute IMO in most brain areas studied: the medial prefrontal cortex (mPFC), lateral septum (LS), medial amygdala (MeA), paraventricular nucleus of the hypothalamus (PVN) and locus coeruleus. In contrast, the number of neurons showing Fos-like immunoreactivity was only reduced in the MeA and the various subregions of the PVN. IMO-induced increases in arc gene expression were restricted to telencephalic regions and reduced by repeated IMO only in the mPFC. Double-labelling in the LS of IMO-exposed rats revealed that arc was expressed in only one-third of Fos+ neurons, suggesting two populations of Fos+ neurons. These data suggest that c-fos mRNA levels are more affected by repeated IMO than corresponding protein, and that arc gene expression does not reflect adaptation in most brain regions, which may be related to its constitutive expression. Therefore, the choice of a particular IEG and the method of measurement are important for proper interpretation of the impact of chronic repeated stress on brain activation.

  3. Probing the possibility of a 12C13C abundance gradient from observations of interstellar CH+

    International Nuclear Information System (INIS)

    Hawkins, I.

    1987-01-01

    I have performed high signal-to-noise (SN /equals/ 300 to 500) observations of interstellar CH/sup /plus// at Lick Observatory and at CTIO of the reddened, early-type stars HD 183143, HD 24432, and HD 157038 in an effort to probe the existence of a 12 C 13 C abundance gradient in our Galaxy

  4. A scanning Hall probe microscope for high resolution magnetic imaging down to 300 mK

    International Nuclear Information System (INIS)

    Khotkevych, V. V.; Bending, S. J.; Milosevic, M. V.

    2008-01-01

    We present the design, construction, and performance of a low-temperature scanning Hall probe microscope with submicron lateral resolution and a large scanning range. The detachable microscope head is mounted on the cold flange of a commercial 3 He-refrigerator (Oxford Instruments, Heliox VT-50) and operates between room temperature and 300 mK. It is fitted with a three-axis slip-stick nanopositioner that enables precise in situ adjustment of the probe location within a 6x6x7 mm 3 space. The local magnetic induction at the sample surface is mapped with an easily changeable microfabricated Hall probe [typically GsAs/AlGaAs or AlGaAs/InGaAs/GaAs Hall sensors with integrated scanning tunnel microscopy (STM) tunneling tips] and can achieve minimum detectable fields ≥10 mG/Hz 1/2 . The Hall probe is brought into very close proximity to the sample surface by sensing and controlling tunnel currents at the integrated STM tip. The instrument is capable of simultaneous tunneling and Hall signal acquisition in surface-tracking mode. We illustrate the potential of the system with images of superconducting vortices at the surface of a Nb thin film down to 372 mK, and also of labyrinth magnetic-domain patterns of an yttrium iron garnet film captured at room temperature.

  5. Probe measurements of hydrogen fluxes during discharge cleaning in JFT-2M

    International Nuclear Information System (INIS)

    Matsuzaki, Y.

    1989-01-01

    Thermal desorption spectroscopy (TDS) has been applied during discharge cleaning in the JFT-2M tokamak to measure hydrogen fluxes. The TDS carbon sample, thickness 0.13 mm, was heated to 1000 0 C by direct current and the temperature distribution of the sample surface measured by infrared thermography. The probe was exposed to three types of plasma: Taylor-type discharge cleaning (TDC), ECR discharge cleaning (ECR-DC), and glow discharge cleaning (GDC). The TDS spectra show peak desorption at around 800 0 C. The hydrogen flux, obtained by integration of the TDS spectrum, decreases exponentially in the radial direction with decay length 7.4 cm and 5.8 cm in TDC and ECR-DC, respectively. The relation between hydrogen fluxes and water vapour production was investigated. In TDC, the amount of water vapour depends more strongly on the electron temperature of the plasma than on the hydrogen flux. In ECR-DC, the production of water vapour increases approximately linearly with the hydrogen-flux. In GDC, hydrogen fluxes were measured by TDS but no water vapour could be detected in the residual gases during the discharge. (orig.)

  6. Development of ion diagnostic system based on electrostatic probe in the boundary plasma of the JFT-2M tokamak

    International Nuclear Information System (INIS)

    Uehara, Kazuya; Kawakami, Tomohide; Amemiya, Hiroshi; Hoethker, K.; Cosler, A.; Bieger, W.

    1995-06-01

    An ion diagnostic system using electrostatic probes for measurements in the JFT-2M tokamak boundary plasma has been developed under the collaboration program between KFA and JAERI. The rotating double probe system, on which the Hoethker double probe and Amemiya asymmetric probe can mounted, are manufactured at KFA workshop while the linear driver to support the rotating double probe, the ion toothbrush probe, the Katsumata probe and the cubic Mach probe are developed at JAERI. This report describes the hardware of this probe system for ion diagnostics in the boundary plasma and preliminary data obtained by means of this system. Furthermore, results on the transport are estimated on the basis of these probe data. (author)

  7. 13CO2/12CO2 isotope ratio analysis in human breath using a 2 μm diode laser

    Science.gov (United States)

    Sun, Mingguo; Cao, Zhensong; Liu, Kun; Wang, Guishi; Tan, Tu; Gao, Xiaoming; Chen, Weidong; Yinbo, Huang; Ruizhong, Rao

    2015-04-01

    The bacterium H. pylori is believed to cause peptic ulcer. H. pylori infection in the human stomach can be diagnosed through a CO2 isotope ratio measure in exhaled breath. A laser spectrometer based on a distributed-feedback semiconductor diode laser at 2 μm is developed to measure the changes of 13CO2/12CO2 isotope ratio in exhaled breath sample with the CO2 concentration of ~4%. It is characterized by a simplified optical layout, in which a single detector and associated electronics are used to probe CO2 spectrum. A new type multi-passes cell with 12 cm long base length , 29 m optical path length in total and 280 cm3 volume is used in this work. The temperature and pressure are well controlled at 301.15 K and 6.66 kPa with fluctuation amplitude of 25 mK and 6.7 Pa, respectively. The best 13δ precision of 0.06o was achieved by using wavelet denoising and Kalman filter. The application of denoising and Kalman filter not only improved the signal to noise ratio, but also shorten the system response time.

  8. Characterization of rat brain NCAM mRNA using DNA oligonucleotide probes

    DEFF Research Database (Denmark)

    Andersson, A M; Gaardsvoll, H; Giladi, E

    1990-01-01

    A number of different isoforms of the neural cell adhesion molecule (NCAM) have been identified. The difference between these is due to alternative splicing of a single NCAM gene. In rat brain NCAM mRNAs with sizes of 7.4, 6.7, 5.2, 4.3 and 2.9 kb have been reported. We have synthesized six DNA...... oligonucleotides, that hybridize to different exons in the NCAM gene. Furthermore we have constructed three oligonucleotides, that exclusively hybridize to mRNAs lacking certain exons, by letting them consist of sequences adjacent to both sides of the splice sites. By means of these probes we have characterized...... the five NCAM mRNAs in rat brain....

  9. 8-13μm spectrophotometry of galaxies

    International Nuclear Information System (INIS)

    Roche, P.F.; Aitken, D.K.; Whitmore, B.

    1983-01-01

    Spectrophotometry at 8-13 μm of Mkn 231 confirms that the 10 μm minimum is due to large columns of silicate dust in the line-of-sight to the nucleus. Fits to the detailed spectral shape demonstrate that the cool absorbing grains are at the emission (z=0.042) rather than the absorption (z approx.= 0.025) redshift and are located within the nuclear region. (author)

  10. Feasibility and repeatability of cold and mechanical quantitative sensory testing in normal dogs

    Science.gov (United States)

    Briley, Jessica D.; Williams, Morika D.; Freire, Mila; Griffith, Emily H.; Lascelles, B. Duncan X.

    2015-01-01

    Feasibility and inter-session repeatability of cold and mechanical quantitative sensory testing (QST) were assessed in 24 normal dogs. Cold thermal latencies were evaluated using a thermal probe (0 °C) applied to three pelvic limb sites. Mechanical thresholds were measured using an electronic von Frey anesthesiometer (EVF) and a blunt-probed pressure algometer (PA) applied to the dorsal aspect of the metatarsus. All QST trials were performed with dogs in lateral recumbency. Collection of cold QST data was easy (feasible) in 19/24 (79%) dogs. However, only 18.4%, 18.9% and 13.2% of cold QST trials elicited a response at the medial tibia, third digital pad and plantar metatarsal regions, respectively. Collection of mechanical QST data was easy (feasible) in 20/24 (83%) dogs for both EVF and PA. At consecutive sampling times, approximately 2 weeks apart, the average EVF sensory thresholds were 414 ± 186 g and 379 ± 166 g, respectively, and the average PA sensory thresholds were 1089 ± 414 g and 1028 ± 331 g, respectively. There was no significant difference in inter-session or inter-limb threshold values for either mechanical QST device. The cold QST protocol in this study was achievable, but did not provide consistently quantifiable results. Both mechanical QST devices tested provided repeatable, reliable sensory threshold measurements in normal, client-owned dogs. These findings contribute to the validation of the EVF and PA as tools to obtain repeated QST data over time in dogs to assess somatosensory processing changes. PMID:24268475

  11. Laser-induced construction of multi-branched CuS nanodendrites with excellent surface-enhanced Raman scattering spectroscopy in repeated applications.

    Science.gov (United States)

    Li, Shuang; Zhang, Hua; Xu, Linlin; Chen, Ming

    2017-07-10

    We report on the successful fabrication of multi-branched CuS nanodendrites with average branch length of about 20 nm by laser ablation of bulk Cu target in thioacetamide (TAA) solution. During the nucleation of Cu and S species, the accurate anisotropic growth should be attributed to an ultra-rapid acid etching process by laser-induced TAA hydrolyzing reaction. Interestingly, the semiconductor CuS nanodendrites provide pronounced surface enhanced Raman scattering (SERS) properties with noble-metal comparable activity and a detection limit as low as ~10 -10 M, approaching the requirement (~nM) for single molecule detection. More importantly, after SERS analysis, the crystal violet (CV) probe molecules can be effectively removed from the substrate by 1064nm laser irradiation-induced moderate thermal treatment. Therefore, the unique and distinctive advantage is that the as-prepared CuS nanodendrites exhibit excellent reusability for 60 cycles of repeated SERS analyses. The low-cost CuS semiconductor nanodendrites with enhanced SERS properties should be established as a prominent SERS-based ultrasensitive probe in the repeated applications.

  12. The development of 1,3-diphenylisobenzofuran as a highly selective probe for the detection and quantitative determination of hydrogen peroxide.

    Science.gov (United States)

    Żamojć, Krzysztof; Zdrowowicz, Magdalena; Rudnicki-Velasquez, Paweł Błażej; Krzymiński, Karol; Zaborowski, Bartłomiej; Niedziałkowski, Paweł; Jacewicz, Dagmara; Chmurzyński, Lech

    2017-01-01

    1,3-Diphenylisobenzofuran (DPBF) has been developed as a selective probe for the detection and quantitative determination of hydrogen peroxide in samples containing different reactive nitrogen and oxygen species (RNOS). DPBF is a fluorescent probe which, for almost 20 years, was believed to react in a highly specific manner toward some reactive oxygen species (ROS) such as singlet oxygen and hydroxy, alkyloxy or alkylperoxy radicals. Under the action of these individuals DPBF has been rapidly transformed to 1,2-dibenzoylbenzene (DBB). In order to check if DPBF can act as a unique indicator of the total amount of different RNOS, as well as oxidative stress caused by an overproduction of these individuals, a series of experiments was carried out, in which DPBF reacted with peroxynitrite anion, superoxide anion, hydrogen peroxide, hypochlorite anion, and anions commonly present under biological conditions, namely nitrite and nitrate. In all cases, except for hydrogen peroxide, the product of the reaction is DBB. Only under the action of H 2 O 2 9-hydroxyanthracen-10(9H)-one (oxanthrone) is formed. This product has been identified with the use of fluorescence spectroscopy, NMR spectroscopy, high performance liquid chromatography coupled with mass spectrometry, infrared spectroscopy, elemental analysis, and cyclic voltammetry (CV). A linear relationship was found between a decrease in the fluorescence intensity of DPBF and the concentration of hydrogen peroxide in the range of concentrations of 0.196-3.941 mM. DPBF responds to hydrogen peroxide in a very specific way with the limits of detection and quantitation of 88 and 122.8 μM, respectively. The kinetics of the reaction between DBBF and H 2 O 2 was also studied.

  13. Performance of field measuring probes for SSC magnets

    International Nuclear Information System (INIS)

    Thomas, R.; Ganetis, G.; Herrera, J.; Hogue, R.; Jain, A.; Louie, W.; Marone, A.; Wanderer, P.

    1993-01-01

    Several years of experience have been acquired on the operation of probes (''moles'') constructed for the measurement of the multipole components of the magnetic fields of SSC magnets. The field is measured by rotating coils contained in a 2.4-m long tube that is pulled through the aperture of the magnet by an external device-the transporter. In addition to the measuring coils, the tube contains motors for rotating the coil and a system for sensing local vertical using gravity sensors to provide an absolute reference for the field measurements. We describe the steps that must be taken in order to ensure accurate, repeatable measurements; the design changes that have been motivated by difficulties encountered (noise, vibration, variations in temperature); and other performance issues. The mechanical interface between the probe and the hewn tube of the magnet is also described

  14. Accuracy of probing attachment levels using a new computerized cemento-enamel junction probe.

    Science.gov (United States)

    Deepa, R; Prakash, Shobha

    2012-01-01

    The assessment of clinical attachment level (CAL) represents the gold standard for diagnosing and monitoring periodontal disease. The aim of the present study was to evaluate the performance of the newly introduced cemento-enamel junction (CEJ) probe in detecting CAL, using CEJ as a fixed reference point, and to compare the CEJ probe with the Florida stent probe (FSP) as well as with a standard manual probe, University of North Carolina-15 (UNC-15). Three examiners recorded the probing attachment level in 384 sites in case group (chronic periodontitis), and in 176 sites, in control group (healthy periodontal status), using the three probes. Subjects included both the sexes and ranged from 35 to 45 years. The experimental design was structured to balance the intra- and inter-examiner consistency at the same site during the two visits. CEJ probe showed higher intra-and inter-examiner consistency over both FSP and UNC-15 in both the case and control groups. Frequency distribution of differences of various magnitudes of repeated measurements ≤1 mm was in the higher range of 86.8% to 87.5% for CEJ probe. The FSP was more reproducible than UNC-15 in detecting relative attachment level (RAL). CEJ automated probe was found to have greatest potential for accuracy and consistency in detecting CAL than FSP and UNC-15. The automated probes appeared to be more reproducible than manual probes.

  15. Characterizing nanoscale scanning probes using electron microscopy: A novel fixture and a practical guide

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, Tevis D. B., E-mail: tjacobs@pitt.edu [Department of Mechanical Engineering and Materials Science, University of Pittsburgh, 3700 O’Hara St., Pittsburgh, Pennsylvania 15208 (United States); Wabiszewski, Graham E.; Goodman, Alexander J.; Carpick, Robert W., E-mail: carpick@seas.upenn.edu [Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 220 S. 33rd St., Philadelphia, Pennsylvania 19104 (United States)

    2016-01-15

    The nanoscale geometry of probe tips used for atomic force microscopy (AFM) measurements determines the lateral resolution, contributes to the strength of the tip-surface interaction, and can be a significant source of uncertainty in the quantitative analysis of results. While inverse imaging of the probe tip has been used successfully to determine probe tip geometry, direct observation of the tip profile using electron microscopy (EM) confers several advantages: it provides direct (rather than indirect) imaging, requires fewer algorithmic parameters, and does not require bringing the tip into contact with a sample. In the past, EM-based observation of the probe tip has been achieved using ad hoc mounting methods that are constrained by low throughput, the risk of contamination, and repeatability issues. We report on a probe fixture designed for use in a commercial transmission electron microscope that enables repeatable mounting of multiple AFM probes as well as a reference grid for beam alignment. This communication describes the design, fabrication, and advantages of this probe fixture, including full technical drawings for machining. Further, best practices are discussed for repeatable, non-destructive probe imaging. Finally, examples of the fixture’s use are described, including characterization of common commercial AFM probes in their out-of-the-box condition.

  16. Heavy ion beam probe development for the plasma potential measurement on the TUMAN-3M tokamak

    International Nuclear Information System (INIS)

    Askinazi, L.G.; Kornev, V.A.; Lebedev, S.V.; Tukachinsky, A.S.; Zhubr, N.A.; Dreval, N.B.; Krupnik, L.I.

    2004-01-01

    The peculiarities of the heavy ion beam probe implementation on the small aspect ratio tokamak TUMAN-3M are analyzed. The toroidal displacement of beam trajectory due to the high I pl /B tor ratio is taken into account when designing the layout of the diagnostic. Numerical calculation of beam trajectories using realistic configuration of TUMAN-3M magnetic fields and parabolic plasma current profile resulted in proper adjustment of probing and detection parameters (probing ion material, energy, entrance angles, detector location, and orientation). Secondary ion energy analyzer gain functions G and F were measured in situ using neutral hydrogen puffed in the tokamak vessel as a target for secondary ions production. The detector unit featured split-plate design and had additional electrodes for secondary electron emission suppression. As a result, the diagnostic is now capable of plasma potential evolution measurement and is sensitive enough to trace the potential profile evolution at the L-H mode transition

  17. The Chemical Composition Contrast between M3 and M13 Revisited: New Abundances for 28 Giant Stars in M3

    Science.gov (United States)

    Sneden, Christopher; Kraft, Robert P.; Guhathakurta, Puragra; Peterson, Ruth C.; Fulbright, Jon P.

    2004-04-01

    We report new chemical abundances of 23 bright red giant members of the globular cluster M3, based on high-resolution (R~45,000) spectra obtained with the Keck I telescope. The observations, which involve the use of multislits in the HIRES Keck I spectrograph, are described in detail. Combining these data with a previously reported small sample of M3 giants obtained with the Lick 3 m telescope, we compare metallicities and [X/Fe] ratios for 28 M3 giants with a 35-star sample in the similar-metallicity cluster M13, and with Galactic halo field stars having [Fe/H]=A(Si), we derive little difference in [X/Fe] ratios in the M3, M13, or halo field samples. All three groups exhibit C depletion with advancing evolutionary state beginning at the level of the red giant branch ``bump,'' but the overall depletion of about 0.7-0.9 dex seen in the clusters is larger than that associated with the field stars. The behaviors of O, Na, Mg, and Al are distinctively different among the three stellar samples. Field halo giants and subdwarfs have a positive correlation of Na with Mg, as predicted from explosive or hydrostatic carbon burning in Type II supernova sites. Both M3 and M13 show evidence of high-temperature proton-capture synthesis from the ON, NeNa, and MgAl cycles, while there is no evidence for such synthesis among halo field stars. But the degree of such extreme proton-capture synthesis in M3 is smaller than it is in M13: the M3 giants exhibit only modest deficiencies of O and corresponding enhancements of Na, less extreme overabundances of Al, fewer stars with low Mg and correspondingly high Na, and no indication that O depletions are a function of advancing evolutionary state, as has been claimed for M13. We have also considered NGC 6752, for which Mg isotopic abundances have been reported by Yong et al. Giants in NGC 6752 and M13 satisfy the same anticorrelation of O abundances with the ratio (25Mg+26Mg)/24Mg, which measures the relative contribution of rare to

  18. Rf probe technology for the next generation of technological plasmas

    International Nuclear Information System (INIS)

    Law, V.J.; Kenyon, A.J.; Thornhill, N.F.; Seeds, A.J.; Batty, I.

    2001-01-01

    We describe radio frequency (rf) analysis of technological plasmas at the 13.56 MHz fundamental drive frequency and integer narrow-band harmonics up to n = 9. In particular, we demonstrate the use of harmonic amplitude information as a process end-point diagnostic. Using very high frequency (vhf) techniques, we construct non-invasive ex situ remote-coupled probes: a diplexer, an equal-ratio-arm bridge, and a dual directional coupler used as a single directional device. These probes bolt into the plasma-tool 50 Ω transmission-line between the rf generator and matching network, and hence do not require modification of the plasma tool. The 50 Ω probe environment produces repeatable measurements of the chamber capacitance and narrow-band harmonic amplitude with an end-point detection sensitivity corresponding to a 2 dB change in the harmonic amplitude with the removal of 1 cm 2 of photoresist. The methodology and design of an instrument for the measurement of the plasma-tool frequency response, and the plasma harmonic amplitude and phase response are examined. The instrument allows the monitoring of the plasma phase delay, plasma-tool short- and long-term ageing, and process end-point prediction. (author)

  19. Probing Motion of Fast Radio Burst Sources by Timing Strongly Lensed Repeaters

    Science.gov (United States)

    Dai, Liang; Lu, Wenbin

    2017-09-01

    Given the possible repetitive nature of fast radio bursts (FRBs), their cosmological origin, and their high occurrence, detection of strongly lensed sources due to intervening galaxy lenses is possible with forthcoming radio surveys. We show that if multiple images of a repeating source are resolved with VLBI, using a method independent of lens modeling, accurate timing could reveal non-uniform motion, either physical or apparent, of the emission spot. This can probe the physical nature of FRBs and their surrounding environments, constraining scenarios including orbital motion around a stellar companion if FRBs require a compact star in a special system, and jet-medium interactions for which the location of the emission spot may randomly vary. The high timing precision possible for FRBs (˜ms) compared with the typical time delays between images in galaxy lensing (≳10 days) enables the measurement of tiny fractional changes in the delays (˜ {10}-9) and hence the detection of time-delay variations induced by relative motions between the source, the lens, and the Earth. We show that uniform cosmic peculiar velocities only cause the delay time to drift linearly, and that the effect from the Earth’s orbital motion can be accurately subtracted, thus enabling a search for non-trivial source motion. For a timing accuracy of ˜1 ms and a repetition rate (of detected bursts) of ˜0.05 per day of a single FRB source, non-uniform displacement ≳0.1-1 au of the emission spot perpendicular to the line of sight is detectable if repetitions are seen over a period of hundreds of days.

  20. Detection of Hepatitis B Virus M204I Mutation by Quantum Dot-Labeled DNA Probe

    Directory of Open Access Journals (Sweden)

    Cheng Zhang

    2017-04-01

    Full Text Available Quantum dots (QDs are semiconductor nanoparticles with a diameter of less than 10 nm, which have been widely used as fluorescent probes in biochemical analysis and vivo imaging because of their excellent optical properties. Sensitive and convenient detection of hepatitis B virus (HBV gene mutations is important in clinical diagnosis. Therefore, we developed a sensitive, low-cost and convenient QDs-mediated fluorescent method for the detection of HBV gene mutations in real serum samples from chronic hepatitis B (CHB patients who had received lamivudine or telbivudine antiviral therapy. We also evaluated the efficiency of this method for the detection of drug-resistant mutations compared with direct sequencing. In CHB, HBV DNA from the serum samples of patients with poor response or virological breakthrough can be hybridized to probes containing the M204I mutation to visualize fluorescence under fluorescence microscopy, where fluorescence intensity is related to the virus load, in our method. At present, the limits of the method used to detect HBV genetic variations by fluorescence quantum dots is 103 IU/mL. These results show that QDs can be used as fluorescent probes to detect viral HBV DNA polymerase gene variation, and is a simple readout system without complex and expensive instruments, which provides an attractive platform for the detection of HBV M204I mutation.

  1. An improved mounting device for attaching intracranial probes in large animal models.

    Science.gov (United States)

    Dunster, Kimble R

    2015-12-01

    The rigid support of intracranial probes can be difficult when using animal models, as mounting devices suitable for the probes are either not available, or designed for human use and not suitable in animal skulls. A cheap and reliable mounting device for securing intracranial probes in large animal models is described. Using commonly available clinical consumables, a universal mounting device for securing intracranial probes to the skull of large animals was developed and tested. A simply made mounting device to hold a variety of probes from 500 μm to 1.3 mm in diameter to the skull was developed. The device was used to hold probes to the skulls of sheep for up to 18 h. No adhesives or cements were used. The described device provides a reliable method of securing probes to the skull of animals.

  2. Performance of field measuring probes for SSC magnets

    International Nuclear Information System (INIS)

    Thomas, R.; Ganetis, G.; Herrera, J.; Hogue, R.; Jain, A.; Louie, W.; Marone, A.; Wanderer, P.

    1994-01-01

    Several years of experience have been acquired on the operation of probes (open-quotes molesclose quotes) constructed for the measurement of the multipole components of the magnetic fields of SSC magnets. The field is measured by rotating coils contained in a 2.4-m long tube that is pulled through the aperture of the magnet by an external device - the transporter. In addition to the measuring coils, the tube contains motors for rotating the coil and a system for sensing local vertical using gravity sensors to provide an absolute reference for the field measurements. The authors describe the steps that must be taken in order to ensure accurate, repeatable measurements; the design changes that have been motivated by difficulties encountered (noise, vibration, variations in temperature); and other performance issues. The mechanical interface between the probe and the beam tube of the magnet is also described

  3. m-Trifluoromethyl-diphenyl Diselenide Regulates Prefrontal Cortical MOR and KOR Protein Levels and Abolishes the Phenotype Induced by Repeated Forced Swim Stress in Mice.

    Science.gov (United States)

    Rosa, Suzan Gonçalves; Pesarico, Ana Paula; Martini, Franciele; Nogueira, Cristina Wayne

    2018-04-05

    The present study aimed to investigate the m-trifluoromethyl-diphenyl diselenide [(m-CF 3 -PhSe) 2 ] effects on prefrontal cortical MOR and KOR protein levels and phenotype induced by repeated forced swim stress (FSS) in mice. Adult Swiss mice were subjected to repeated FSS sessions, and after that, they performed the spontaneous locomotor/exploratory activity, tail suspension, and splash tests. (m-CF 3 -PhSe) 2 (0.1 to 5 mg/kg) was administered to mice 30 min before the first FSS session and 30 min before the subsequent repeated FSS. (m-CF 3 -PhSe) 2 abolished the phenotype induced by repeated FSS in mice. In addition, a single FSS session increased μ but reduced δ-opioid receptor contents, without changing the κ content. Mice subjected to repeated FSS had an increase in the μ content when compared to those of naïve group or subjected to single FSS. Repeated FSS induced an increase of δ-opioid receptor content compared to those mice subjected to single FSS. However, the δ-opioid receptor contents were lower than those found in the naïve group. The mice subjected to repeated FSS showed an increase in the κ-opioid receptor content when compared to that of the naïve mice. (m-CF 3 -PhSe) 2 regulated the protein contents of μ and κ receptors in mice subjected to repeated FSS. These findings demonstrate that (m-CF 3 -PhSe) 2 was effective to abolish the phenotype induced by FSS, which was accompanied by changes in the contents of cortical μ- and κ-opioid receptors.

  4. Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.

    Science.gov (United States)

    Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S

    2014-06-01

    A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.

  5. Evaluation of 13 short tandem repeated loci for use in personal identification applications

    Energy Technology Data Exchange (ETDEWEB)

    Hammond, H.A.; Caskey, C.T. (Baylor College of Medicine, Houston, TX (United States)); Jin, L.; Zhong, Y.; Chakraborty, R. (Univ. of Texas Graduate School of Biomedical Sciences, Houston, TX (United States))

    1994-07-01

    Personal identification by using DNA typing methodologies has been an issue in the popular and scientific press for several years. The authors present a PCR-based DNA-typing method using 13 unlinked short tandem repeat (STR) loci. Validation of the loci and methodology has been performed to meet standards set by the forensic community and the accrediting organization for parentage testing. Extensive statistical analysis has addressed the issues surrounding the presentation of [open quotes]match[close quotes] statistics. The authors have found STR loci to provide a rapid, sensitive, and reliable method of DNA typing for parentage testing, forensic identification, and medical diagnostics. Valid statistical analysis is generally simpler than similar analysis of RFLP-VNTR results and provides powerful statistical evidence of the low frequency of random multilocus genotype matching. 54 refs., 4 figs., 6 tabs.

  6. A simple repeat polymorphism in the MITF-M promoter is a key regulator of white spotting in dogs.

    Directory of Open Access Journals (Sweden)

    Izabella Baranowska Körberg

    Full Text Available The white spotting locus (S in dogs is colocalized with the MITF (microphtalmia-associated transcription factor gene. The phenotypic effects of the four S alleles range from solid colour (S to extreme white spotting (s(w. We have investigated four candidate mutations associated with the s(w allele, a SINE insertion, a SNP at a conserved site and a simple repeat polymorphism all associated with the MITF-M promoter as well as a 12 base pair deletion in exon 1B. The variants associated with white spotting at all four loci were also found among wolves and we conclude that none of these could be a sole causal mutation, at least not for extreme white spotting. We propose that the three canine white spotting alleles are not caused by three independent mutations but represent haplotype effects due to different combinations of causal polymorphisms. The simple repeat polymorphism showed extensive diversity both in dogs and wolves, and allele-sharing was common between wolves and white spotted dogs but was non-existent between solid and spotted dogs as well as between wolves and solid dogs. This finding was unexpected as Solid is assumed to be the wild-type allele. The data indicate that the simple repeat polymorphism has been a target for selection during dog domestication and breed formation. We also evaluated the significance of the three MITF-M associated polymorphisms with a Luciferase assay, and found conclusive evidence that the simple repeat polymorphism affects promoter activity. Three alleles associated with white spotting gave consistently lower promoter activity compared with the allele associated with solid colour. We propose that the simple repeat polymorphism affects cooperativity between transcription factors binding on either flanking sides of the repeat. Thus, both genetic and functional evidence show that the simple repeat polymorphism is a key regulator of white spotting in dogs.

  7. Cognitive enhancement and antipsychotic-like activity following repeated dosing with the selective M4 PAM VU0467154.

    Science.gov (United States)

    Gould, Robert W; Grannan, Michael D; Gunter, Barak W; Ball, Jacob; Bubser, Michael; Bridges, Thomas M; Wess, Jurgen; Wood, Michael W; Brandon, Nicholas J; Duggan, Mark E; Niswender, Colleen M; Lindsley, Craig W; Conn, P Jeffrey; Jones, Carrie K

    2018-01-01

    Although selective activation of the M 1 muscarinic acetylcholine receptor (mAChR) subtype has been shown to improve cognitive function in animal models of neuropsychiatric disorders, recent evidence suggests that enhancing M 4 mAChR function can also improve memory performance. Positive allosteric modulators (PAMs) targeting the M 4 mAChR subtype have shown therapeutic potential for the treatment of multiple symptoms observed in schizophrenia, including positive and cognitive symptoms when assessed in acute preclinical dosing paradigms. Since the cholinergic system has been implicated in multiple stages of learning and memory, we evaluated the effects of repeated dosing with the highly selective M 4 PAM VU0467154 on either acquisition and/or consolidation of learning and memory when dosed alone or after pharmacologic challenge with the N-methyl-d-aspartate subtype of glutamate receptors (NMDAR) antagonist MK-801. MK-801 challenge represents a well-documented preclinical model of NMDAR hypofunction that is thought to underlie some of the positive and cognitive symptoms observed in schizophrenia. In wildtype mice, 10-day, once-daily dosing of VU0467154 either prior to, or immediately after daily testing enhanced the rate of learning in a touchscreen visual pairwise discrimination task; these effects were absent in M 4 mAChR knockout mice. Following a similar 10-day, once-daily dosing regimen of VU0467154, we also observed 1) improved acquisition of memory in a cue-mediated conditioned freezing paradigm, 2) attenuation of MK-801-induced disruptions in the acquisition of memory in a context-mediated conditioned freezing paradigm and 3) reversal of MK-801-induced hyperlocomotion. Comparable efficacy and plasma and brain concentrations of VU0467154 were observed after repeated dosing as those previously reported with an acute, single dose administration of this M 4 PAM. Together, these studies are the first to demonstrate that cognitive enhancing and antipsychotic

  8. A Defective mRNA Cleavage and Polyadenylation Complex Facilitates Expansions of Transcribed (GAAn Repeats Associated with Friedreich’s Ataxia

    Directory of Open Access Journals (Sweden)

    Ryan J. McGinty

    2017-09-01

    Full Text Available Expansions of microsatellite repeats are responsible for numerous hereditary diseases in humans, including myotonic dystrophy and Friedreich’s ataxia. Whereas the length of an expandable repeat is the main factor determining disease inheritance, recent data point to genomic trans modifiers that can impact the likelihood of expansions and disease progression. Detection of these modifiers may lead to understanding and treating repeat expansion diseases. Here, we describe a method for the rapid, genome-wide identification of trans modifiers for repeat expansion in a yeast experimental system. Using this method, we found that missense mutations in the endoribonuclease subunit (Ysh1 of the mRNA cleavage and polyadenylation complex dramatically increase the rate of (GAAn repeat expansions but only when they are actively transcribed. These expansions correlate with slower transcription elongation caused by the ysh1 mutation. These results reveal an interplay between RNA processing and repeat-mediated genome instability, confirming the validity of our approach.

  9. Isolation of human simple repeat loci by hybridization selection.

    Science.gov (United States)

    Armour, J A; Neumann, R; Gobert, S; Jeffreys, A J

    1994-04-01

    We have isolated short tandem repeat arrays from the human genome, using a rapid method involving filter hybridization to enrich for tri- or tetranucleotide tandem repeats. About 30% of clones from the enriched library cross-hybridize with probes containing trimeric or tetrameric tandem arrays, facilitating the rapid isolation of large numbers of clones. In an initial analysis of 54 clones, 46 different tandem arrays were identified. Analysis of these tandem repeat loci by PCR showed that 24 were polymorphic in length; substantially higher levels of polymorphism were displayed by the tetrameric repeat loci isolated than by the trimeric repeats. Primary mapping of these loci by linkage analysis showed that they derive from 17 chromosomes, including the X chromosome. We anticipate the use of this strategy for the efficient isolation of tandem repeats from other sources of genomic DNA, including DNA from flow-sorted chromosomes, and from other species.

  10. Cyclosporin A Impairs the Secretion and Activity of ADAMTS13 (A Disintegrin and Metalloprotease with Thrombospondin Type 1 Repeat)*

    Science.gov (United States)

    Hershko, Klilah; Simhadri, Vijaya L.; Blaisdell, Adam; Hunt, Ryan C.; Newell, Jordan; Tseng, Sandra C.; Hershko, Alon Y.; Choi, Jae Won; Sauna, Zuben E.; Wu, Andrew; Bram, Richard J.; Komar, Anton A.; Kimchi-Sarfaty, Chava

    2012-01-01

    The protease ADAMTS13 (a disintegrin and metalloprotease with thrombospondin type 1 repeat) cleaves multimers of von Willebrand factor, thus regulating platelet aggregation. ADAMTS13 deficiency leads to the fatal disorder thrombotic thrombocytopenic purpura (TTP). It has been observed that cyclosporin A (CsA) treatment, particularly in transplant patients, may sometimes be linked to the development of TTP. Until now, the reason for such a link was unclear. Here we provide evidence demonstrating that cyclophilin B (CypB) activity plays an important role in the secretion of active ADAMTS13. We found that CsA, an inhibitor of CypB, reduces the secretion of ADAMTS13 and leads to conformational changes in the protein resulting in diminished ADAMTS13 proteolytic activity. A direct, functional interaction between CypB (which possesses peptidyl-prolyl cis-trans isomerase (PPIase) and chaperone functions) and ADAMTS13 is demonstrated using immunoprecipitation and siRNA knockdown of CypB. Finally, CypB knock-out mice were found to have reduced ADAMTS13 levels. Taken together, our findings indicate that cyclophilin-mediated activity is an important factor affecting secretion and activity of ADAMTS13. The large number of proline residues in ADAMTS13 is consistent with the important role of cis-trans isomerization in the proper folding of this protein. These results altogether provide a novel mechanistic explanation for CsA-induced TTP in transplant patients. PMID:23144461

  11. Cyclosporin A impairs the secretion and activity of ADAMTS13 (a disintegrin and metalloprotease with thrombospondin type 1 repeat).

    Science.gov (United States)

    Hershko, Klilah; Simhadri, Vijaya L; Blaisdell, Adam; Hunt, Ryan C; Newell, Jordan; Tseng, Sandra C; Hershko, Alon Y; Choi, Jae Won; Sauna, Zuben E; Wu, Andrew; Bram, Richard J; Komar, Anton A; Kimchi-Sarfaty, Chava

    2012-12-28

    The protease ADAMTS13 (a disintegrin and metalloprotease with thrombospondin type 1 repeat) cleaves multimers of von Willebrand factor, thus regulating platelet aggregation. ADAMTS13 deficiency leads to the fatal disorder thrombotic thrombocytopenic purpura (TTP). It has been observed that cyclosporin A (CsA) treatment, particularly in transplant patients, may sometimes be linked to the development of TTP. Until now, the reason for such a link was unclear. Here we provide evidence demonstrating that cyclophilin B (CypB) activity plays an important role in the secretion of active ADAMTS13. We found that CsA, an inhibitor of CypB, reduces the secretion of ADAMTS13 and leads to conformational changes in the protein resulting in diminished ADAMTS13 proteolytic activity. A direct, functional interaction between CypB (which possesses peptidyl-prolyl cis-trans isomerase (PPIase) and chaperone functions) and ADAMTS13 is demonstrated using immunoprecipitation and siRNA knockdown of CypB. Finally, CypB knock-out mice were found to have reduced ADAMTS13 levels. Taken together, our findings indicate that cyclophilin-mediated activity is an important factor affecting secretion and activity of ADAMTS13. The large number of proline residues in ADAMTS13 is consistent with the important role of cis-trans isomerization in the proper folding of this protein. These results altogether provide a novel mechanistic explanation for CsA-induced TTP in transplant patients.

  12. Random and Systematic Errors Share in Total Error of Probes for CNC Machine Tools

    Directory of Open Access Journals (Sweden)

    Adam Wozniak

    2018-03-01

    Full Text Available Probes for CNC machine tools, as every measurement device, have accuracy limited by random errors and by systematic errors. Random errors of these probes are described by a parameter called unidirectional repeatability. Manufacturers of probes for CNC machine tools usually specify only this parameter, while parameters describing systematic errors of the probes, such as pre-travel variation or triggering radius variation, are used rarely. Systematic errors of the probes, linked to the differences in pre-travel values for different measurement directions, can be corrected or compensated, but it is not a widely used procedure. In this paper, the share of systematic errors and random errors in total error of exemplary probes are determined. In the case of simple, kinematic probes, systematic errors are much greater than random errors, so compensation would significantly reduce the probing error. Moreover, it shows that in the case of kinematic probes commonly specified unidirectional repeatability is significantly better than 2D performance. However, in the case of more precise strain-gauge probe systematic errors are of the same order as random errors, which means that errors correction or compensation, in this case, would not yield any significant benefits.

  13. Quantitative radiocardiography by single-probe counting using sup(99m)technetium albumin

    International Nuclear Information System (INIS)

    Man in 't Veld, A.J.; Wenting, G.J.; Verhoeven, R.P.; Schalekamp, M.A.D.H.

    1978-01-01

    Quantitative radiocardiography with sup(99m)Technetium albumin, using a single probe for percordial counting of radioactivity is a non-invasive technique to measure cardiac output. sup(99m)Technetium pertechnetate is bound to albumin by electrolytic complexation. Preparations of sup(99m)Technetium albumin showed small percentages of free radioactivity. In-vivo stability of the complex was confirmed by comparison with distribution volumes of 131 Iodine albumin and sup(113m)Indium transferrin. The isotope dilution cardiac output technique was validated by comparison with a classical indocyanine green dilution method. Results obtained by peripheral intravenous injection of the isotope were not different from those after intracardiac injection. Exact localization of the collimator over the heart was not critical. Duplicate measurements showed good reproducibility. Examples of serial measurements in patients with hyperthyroidism, primary aldosteronism and essential hypertinsion are given. The method is reliable, accurate and safe and causes no discomfort to the patient. (C.F.)

  14. Unusually effective microRNA targeting within repeat-rich coding regions of mammalian mRNAs

    Science.gov (United States)

    Schnall-Levin, Michael; Rissland, Olivia S.; Johnston, Wendy K.; Perrimon, Norbert; Bartel, David P.; Berger, Bonnie

    2011-01-01

    MicroRNAs (miRNAs) regulate numerous biological processes by base-pairing with target messenger RNAs (mRNAs), primarily through sites in 3′ untranslated regions (UTRs), to direct the repression of these targets. Although miRNAs have sometimes been observed to target genes through sites in open reading frames (ORFs), large-scale studies have shown such targeting to be generally less effective than 3′ UTR targeting. Here, we show that several miRNAs each target significant groups of genes through multiple sites within their coding regions. This ORF targeting, which mediates both predictable and effective repression, arises from highly repeated sequences containing miRNA target sites. We show that such sequence repeats largely arise through evolutionary duplications and occur particularly frequently within families of paralogous C2H2 zinc-finger genes, suggesting the potential for their coordinated regulation. Examples of ORFs targeted by miR-181 include both the well-known tumor suppressor RB1 and RBAK, encoding a C2H2 zinc-finger protein and transcriptional binding partner of RB1. Our results indicate a function for repeat-rich coding sequences in mediating post-transcriptional regulation and reveal circumstances in which miRNA-mediated repression through ORF sites can be reliably predicted. PMID:21685129

  15. MnO2 nanosheet mediated "DD-A" FRET binary probes for sensitive detection of intracellular mRNA.

    Science.gov (United States)

    Ou, Min; Huang, Jin; Yang, Xiaohai; Quan, Ke; Yang, Yanjing; Xie, Nuli; Wang, Kemin

    2017-01-01

    The donor donor-acceptor (DD-A) FRET model has proven to have a higher FRET efficiency than donor-acceptor acceptor (D-AA), donor-acceptor (D-A), and donor donor-acceptor acceptor (DD-AA) FRET models. The in-tube and in-cell experiments clearly demonstrate that the "DD-A" FRET binary probes can indeed increase the FRET efficiency and provide higher imaging contrast, which is about one order of magnitude higher than the ordinary "D-A" model. Furthermore, MnO 2 nanosheets were employed to deliver these probes into living cells for intracellular TK1 mRNA detection because they can adsorb ssDNA probes, penetrate across the cell membrane and be reduced to Mn 2+ ions by intracellular GSH. The results indicated that the MnO 2 nanosheet mediated "DD-A" FRET binary probes are capable of sensitive and selective sensing gene expression and chemical-stimuli changes in gene expression levels in cancer cells. We believe that the MnO 2 nanosheet mediated "DD-A" FRET binary probes have the potential as a simple but powerful tool for basic research and clinical diagnosis.

  16. The 2001 January 13th M {W}7.7 and February 13th M {W}6.6 El Salvador Earthquakes: Deformation and Stress Triggering

    Science.gov (United States)

    Hreinsdóttir, S.; Freymueller, J. T.

    2001-12-01

    On the 13th of January 2001, an M {W} 7.7 normal fault earthquake occurred offshore El Salvador. The earthquake occurred in the subducting Cocos plate and was followed by high seismic activity and several earthquakes exceeding magnitude 5. On the 13th of February, an M {W} 6.6 strike slip earthquake occurred in the overriding Caribbean plate, about 75 km NNW from the epicenter of the large January earthquake. Deformation due to these earthquakes was observed at six continuous CORS GPS stations in Central America. In the M {W} 7.7 earthquake about 10 mm displacement was measured at GPS stations in El Salvador and Honduras. A smaller but significant dispacement was also observed at GPS stations in Nicaragua, more then 200 km from the earthquake's epicenter. In the M {W} 6.6 earthquake 41+/- 1 mm displacement in direction N111oE was measured at the GPS station in San Salvador, El Salvador. Other CORS GPS stations were not affected by that earthquake. A postsesmic signal is detectable at the San Salvador GPS station, strongest right after the earthquake and then decays. On average we see 0.3 +/- 0.1 mm/day of SSW motion of the station in the first twenty days following the earthquake. Using seismic and geodetic data, we calculated Coulomb stress changes following the January 13th, M {W} 7.7 earthquake. Of special interest were six 5.4 earthquake that occurred in the overriding Caribean plate. The location and focal mechanism of these earthquakes correlate with areas of calculated increase in static stress thus indicating stress triggering. The thrust events occurred 2 to 20 days after the M {W} 7.7 earthquake, in increasing distance from the M {W} 7.7 event with time.

  17. Neutral Probe Beam q-profile measurements in PDX and PBX-M

    International Nuclear Information System (INIS)

    Kugel, H.W.; Gammel, G.M.; Kaita, R.; Reusch, M.F.; Roberts, D.W.

    1988-06-01

    Using the Fast Ion Diagnostic Experiment (FIDE) technique, a Neutral Probe Beam (NPB) can be aimed to inject tangentially to a magnetic surface. The resultant ion orbit shifts, due to conservation of canonical toroidal angular momentum, can be measured with a multi-sightline charge-exchange analyzer to yield direct measurements of radial magnetic flux profiles, current density profiles, the radial position of the magnetic axis, flux surface inner and outer edges, q-profiles, and central-q time dependencies. An extensive error analysis was performed on previous PDX q-measurements in circular plasmas and the resulting estimated contributions of various systematic effects are discussed. Preliminary results of fast ion orbit shift measurements at early times in indented PBX-M plasmas are given. Methods for increasing the absolute experimental precision of similar measurements in progress on PBX-M are discussed. 4 refs., 3 figs

  18. Development of a virtual probe tip with an application to high aspect ratio microscale features

    International Nuclear Information System (INIS)

    Bauza, Marcin B.; Hocken, Robert J.; Smith, Stuart T.; Woody, Shane C.

    2005-01-01

    Nondestructive measurement of microscale features remains a challenging metrology problem. For example, to assess a high aspect ratio small hole it is currently common to cut a cross section and measure the features of interest using an atomic force microscope, scanning probe microscope, or scanning electron microscope. Typically, these metrology tools may be suitable for surface finish measurement but often lack the capability for dimensional metrology. The aim of this article is to discuss the development of a high aspect-ratio microscale probe for measurement of microscale features. A 700:1 high aspect ratio probe shank is fabricated with a 7 μm diameter, and attached at one end to an oscillator. The oscillator produces a standing wave in the oscillating probe shank as opposed to conventional probes that use a microscale sphere on the end of a comparatively rigid shank. As a result of the standing wave formed in steady state vibration, the free end of the shank generates an amplitude of oscillation greater than the probe shank diameter. Thus, the probe does not require a spherical ball to serve as the contact point and simply uses the contact diameter of the free end of the vibrating shank. This methodology is referred to as a virtual probe tip. The virtual probe tip in conjunction with a nanopositioning scanner is used to measure surface profile measurements over traverse lengths of 130 μm. In this article, results from profiles of a 500 nm step height and a ruby sphere of diameter 1 mm are presented. Experiments in this article indicate the ability to repeatedly resolve surface features of less than 5 nm while maintaining bandwidths greater than 1 kHz. Furthermore, adhesion problems often encountered with micrometer scaled probes were not observed during profile measurements with this virtual probe

  19. A study on the repeatability of ultrasonic testing data

    International Nuclear Information System (INIS)

    Yoshimura, Seiichi; Fukumoto, Hiroshi

    1980-01-01

    Reliability improvement of ultrasonic testing data is strongly desired in ultrasonic testing working of nuclear power plants. This paper deals with the problems of the testing by the manual and the remote control apparatus, and with the factors which influence the repeatability of ultrasonic testing data. Following results are found in it. (1) In the testing by the manual, working time and posture influence the repeatability of testing data. (2) Glycerin in suitable for the couplant in the respect of the repeatability of testing data. In the case of using machine oil, the pressure to the probe necessitates to be over 0.2 kg/cm 2 . (3) In the testing by the remote control apparatus, working time, working environment and defect position does not influence the repeatability of testing data. (author)

  20. RGD peptide-displaying M13 bacteriophage/PLGA nanofibers as cell-adhesive matrices for smooth muscle cells

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Yong Cheol; Lee, Jong Ho; Jin, Oh Seong; Lee, Eun Ji; Jin, Lin Hua; Kim, Chang Seok; Hong, Suck Won; Han, Dong Wook; Kim, Chun Tae; Oh, Jin Woo [Pusan National University, Busan (Korea, Republic of)

    2015-01-15

    Extracellular matrices (ECMs) are network structures that play an essential role in regulating cellular growth and differentiation. In this study, novel nanofibrous matrices were fabricated by electrospinning M13 bacteriophage and poly(lactic-co-glycolic acid) (PLGA) and were shown to be structurally and functionally similar to natural ECMs. A genetically-engineered M13 bacteriophage was constructed to display Arg-Gly-Asp (RGD) peptides on its surface. The physicochemical properties of RGD peptide-displaying M13 bacteriophage (RGD-M13 phage)/PLGA nanofibers were characterized by using scanning electron microscopy and Fourier-transform infrared spectroscopy. We used immunofluorescence staining to confirm that M13 bacteriophages were homogenously distributed in RGD-M13 phage/PLGA matrices. Furthermore, RGD-M13 phage/PLGA nanofibrous matrices, having excellent biocompatibility, can enhance the behaviors of vascular smooth muscle cells. This result suggests that RGD-M13 phage/PLGA nanofibrous matrices have potentials to serve as tissue engineering scaffolds.

  1. M13 Bacteriophage-Polymer Nanoassemblies as Drug Delivery Vehicles

    Science.gov (United States)

    2011-01-01

    2011, 4(5): 483–493 490 a solution of folic acid, EDC, and sulfo-NHS (in a molar ratio of 1:1.1:2.5) in anhydrous dimethylsulfoxide ( DMSO ) (1 mL...and stirred overnight. The mass ratio of M13 to PCL–P2VP was 1:5, whereas the solvent ratio of buffer to THF was 19:1. Free DOX was removed from FA

  2. Advantages of the first-derivative probe technique over the three- and four-parameter probe techniques in fusion plasmas diagnostics

    Czech Academy of Sciences Publication Activity Database

    Hasan, E.; Dimitrova, Miglena; Popov, T.; Ivanova, P.; Dejarnac, Renaud; Stöckel, Jan; Pánek, Radomír

    2018-01-01

    Roč. 13, č. 4 (2018), č. článku P04005. ISSN 1748-0221 R&D Projects: GA MŠk(CZ) LM2015045 Institutional support: RVO:61389021 Keywords : Plasma potential * electron temperature * bi-Maxwellian EEDF * Divertor Langmuir probes * three- and four-parameter probe techniques * first-derivative probe technique Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/13/04/P04005/meta

  3. Influence of probe motion on laser probe temperature in circulating blood.

    Science.gov (United States)

    Hehrlein, C; Splinter, R; Littmann, L; Tuntelder, J R; Tatsis, G P; Svenson, R H

    1991-01-01

    The purpose of this study was to evaluate the effect of probe motion on laser probe temperature in various blood flow conditions. Laser probe temperatures were measured in an in vitro blood circulation model consisting of 3.2 nm-diameter plastic tubes. A 2.0 mm-diameter metal probe attached to a 300 microns optical quartz fiber was coupled to an argon laser. Continuous wave 4 watts and 8 watts of laser power were delivered to the fiber tip corresponding to a 6.7 +/- 0.5 and 13.2 +/- 0.7 watts power setting at the laser generator. The laser probe was either moved with constant velocity or kept stationary. A thermocouple inserted in the lateral portion of the probe was used to record probe temperatures. Probe temperature changes were found with the variation of laser power, probe velocity, blood flow, and duration of laser exposure. Probe motion significantly reduced probe temperatures. After 10 seconds of 4 watts laser power the probe temperature in stagnant blood decreased from 303 +/- 18 degrees C to 113 +/- 17 degrees C (63%) by moving the probe with a velocity of 5 cm/sec. Blood flow rates of 170 ml/min further decreased the probe temperature from 113 +/- 17 degrees C to 50 +/- 8 degrees C (56%). At 8 watts of laser power a probe temperature reduction from 591 +/- 25 degrees C to 534 +/- 36 degrees C (10%) due to 5 cm/sec probe velocity was noted. Probe temperatures were reduced to 130 +/- 30 degrees C (78%) under the combined influence of 5 cm/sec probe velocity and 170 ml/min blood flow.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Medical students who decompress during the M-1 year outperform those who fail and repeat it: A study of M-1 students at the University of Illinois College of Medicine at Urbana-Champaign 1988–2000

    Directory of Open Access Journals (Sweden)

    Freund Gregory G

    2005-05-01

    Full Text Available Abstract Background All medical schools must counsel poor-performing students, address their problems and assist them in developing into competent physicians. The objective of this study was to determine whether students with academic deficiencies in their M-1 year graduate more often, spend less time to complete the curriculum, and need fewer attempts at passing USMLE Step 1 and Step 2 by entering the Decompressed Program prior to failure of the M-1 year than those students who fail the M-1 year and then repeat it. Method The authors reviewed the performance of M-1 students in the Decompressed Program and compared their outcomes to M-1 students who failed and fully repeated the M-1 year. To compare the groups upon admission, t-Tests comparing the Cognitive Index of students and MCAT scores from both groups were performed. Performance of the two groups after matriculation was also analyzed. Results Decompressed students were 2.1 times more likely to graduate. Decompressed students were 2.5 times more likely to pass USMLE Step 1 on the first attempt than the repeat students. In addition, 46% of those in the decompressed group completed the program in five years compared to 18% of the repeat group. Conclusion Medical students who decompress their M-1 year prior to M-1 year failure outperform those who fail their first year and then repeat it. These findings indicate the need for careful monitoring of M-1 student performance and early intervention and counseling of struggling students.

  5. Application of 13C-stable isotope probing to identify RDX-degrading microorganisms in groundwater

    International Nuclear Information System (INIS)

    Cho, Kun-Ching; Lee, Do Gyun; Roh, HyungKeun; Fuller, Mark E.; Hatzinger, Paul B.; Chu, Kung-Hui

    2013-01-01

    We employed stable isotope probing (SIP) with 13 C-labeled hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) to identify active microorganisms responsible for RDX biodegradation in groundwater microcosms. Sixteen different 16S rRNA gene sequences were derived from microcosms receiving 13 C-labeled RDX, suggesting the presence of microorganisms able to incorporate carbon from RDX or its breakdown products. The clones, residing in Bacteroidia, Clostridia, α-, β- and δ-Proteobacteria, and Spirochaetes, were different from previously described RDX degraders. A parallel set of microcosms was amended with cheese whey and RDX to evaluate the influence of this co-substrate on the RDX-degrading microbial community. Cheese whey stimulated RDX biotransformation, altered the types of RDX-degrading bacteria, and decreased microbial community diversity. Results of this study suggest that RDX-degrading microorganisms in groundwater are more phylogenetically diverse than what has been inferred from studies with RDX-degrading isolates. Highlights: •SIP identified sixteen groundwater bacteria capable of using RDX and/or its metabolites as a carbon source. •The RDX degraders in groundwater are phylogenetically diverse and different from known RDX degraders. •Cheese whey induced community shift and altered diversity of the RDX-degrading microorganisms over time. -- RDX-degrading bacteria in contaminated groundwater, identified by SIP with 13 C-labeled RDX, are phylogenetically diverse and different from known RDX degraders

  6. The Hera Saturn Entry Probe Mission: a Proposal in Response to the ESA M5 Call

    Science.gov (United States)

    Mousis, Olivier; Atkinson, David; Amato, Michael; Aslam, Shahid; Atreya, Sushil; Blanc, Michel; Bolton, Scott; Brugger, Bastien; Calcutt, Simon; Cavalié, Thibault; Charnoz, Sébastien; Coustenis, Athena; Deleuil, Magali; Dobrijevic, Michel; Ferri, Francesca; Fletcher, Leigh; Gautier, Daniel; Guillot, Tristan; Hartogh, Paul; Holland, Andrew

    2017-04-01

    The Hera Saturn entry probe mission is proposed as an ESA M-class mission to be piggybacked on a NASA spacecraft sent to or past the Saturn system. Hera consists of an atmospheric probe built by ESA and released into the atmosphere of Saturn by its NASA companion Saturn Carrier-Relay spacecraft. Hera will perform in situ measurements of the chemical and isotopic composition as well as the structure and dynamics of Saturn's atmosphere using a single probe, with the goal of improving our understanding of the origin, formation, and evolution of Saturn, the giant planets and their satellite systems, with extrapolation to extrasolar planets. Hera will probe well into and possibly beneath the cloud-forming region of the troposphere, below the region accessible to remote sensing, to locations where certain cosmogenically abundant species are expected to be well mixed. The Hera probe will be designed from ESA elements with possible contributions from NASA, and the Saturn/Carrier-Relay Spacecraft will be supplied by NASA through its selection via the New Frontier 2016 call or in the form of a flagship mission selected by the NASA "Roadmaps to Ocean Worlds" (ROW) program. The Hera probe will be powered by batteries, and we therefore anticipate only one major subsystems to be possibly supplied by the United States, either by direct procurement by ESA or by contribution from NASA: the thermal protection system of the probe. Following the highly successful example of the Cassini-Huygens mission, Hera will carry European and American instruments, with scientists and engineers from both agencies and many affiliates participating in all aspects of mission development and implementation. A Saturn probe is one of the six identified desired themes by the Planetary Science Decadal Survey committee on the NASA New Frontier's list, providing additional indication that a Saturn probe is of extremely high interest and a very high priority for the international community.

  7. 99mTc complexes of 1,3-propanedithiol derivatives

    International Nuclear Information System (INIS)

    Alagui, A.; Apparu, M.; Vidal, M.; Mathieu, J.P.

    1987-01-01

    The labelling of 1,3-n alkylpropanedithiols and of 15-(1,3-dimercapto 2-propyl)pentadecanoic acid by 99m Tc was performed by an exchange reaction with the hexachlorotechnetate ion 99m TcCl 6 2- and by reduction of 99m TcO 4 - with Sn(II) in the presence of the ligand. The biological distribution of the exotechnetium complexes obtained by the latter method in mouse does not reveal a high tropism of these labelling compounds in relation to a particular tissue. (author) 14 refs.; 2 tabs

  8. Selective Deactivation of M13 Bacteriophage in E. Coli using Femtosecond Laser Pulses

    CSIR Research Space (South Africa)

    Molukanele, P

    2010-09-01

    Full Text Available Deactivation of M13 Bacteriophage in E. Coli using Femtosecond Laser Pulses P. Molukanele 1, 3, A. Du Plessis 1, T. Roberts 1, L. Botha 1, M. Khati 2,3, W. Campos 2, 3 1CSIR National Laser Centre, Femtosecond Science group, Pretoria, South Africa 2CSIR... that is about 1 ?m long and 5-6 nm in diameter. Its host Escherichia coli (E.coli), is approximately 2-6 ?m long and 1-1.5 ?m in diameter, see figure 1 below. Figure 1: Schematic representations of M13 bacteriophage and its host E.coli...

  9. Single, 14-Day, and 13-Week Repeated Dose Toxicity Studies of Daily Oral Gelidium elegans Extract Administration to Rats.

    Science.gov (United States)

    Choi, Jia; Ryu, Su-Jung; Kim, Kui-Jin; Kim, Hyung-Min; Chung, Hee-Chul; Lee, Boo-Yong

    2018-01-20

    Gelidium elegans extract (GEE) is derived from a red alga from the Asia-Pacific region, which has antioxidant, anti-adipogenic, and anti-hyperglycemic effects. However, detailed studies of the toxicology of GEE have not been performed. We evaluated the single oral dose toxicity of GEE in male and female Sprague-Dawley (CD) rats. GEE did not cause deaths or have toxic effects at dosages of 5000 mg/kg/day, although compound-colored stools and diarrhea were observed in both sexes, which lasted 5000 mg/kg. We next evaluated the repeated oral dose toxicity of GEE in CD rats over 14 days and 13 weeks. GEE did not induce any significant toxicological changes in either sex at 2000 mg/kg/day. Repeated oral dose toxicity studies showed no adverse effects, in terms of clinical signs, mortality, body mass, food consumption, ophthalmic examination, urinalysis, hematology, serum biochemistry, necropsy, organ masses, or histopathology, at dosages of 500, 1000, or 2000 mg/kg/day. The no observed adverse effect level (NOAEL) for GEE is thus likely to be >2000 mg/kg/day, and no pathology was identified in potential target organs. Therefore, this study indicates that repeated oral dosing with GEE is safe in CD rats.

  10. Aluminum-thin-film packaged fiber Bragg grating probes for monitoring the maximum tensile strain of composite materials.

    Science.gov (United States)

    Im, Jooeun; Kim, Mihyun; Choi, Ki-Sun; Hwang, Tae-Kyung; Kwon, Il-Bum

    2014-06-10

    In this paper, new fiber Bragg grating (FBG) sensor probes are designed to intermittently detect the maximum tensile strain of composite materials, so as to evaluate the structural health status. This probe is fabricated by two thin Al films bonded to an FBG optical fiber and two supporting brackets, which are fixed on the surface of composite materials. The residual strain of the Al packaged FBG sensor probe is induced by the strain of composite materials. This residual strain can indicate the maximum strain of composite materials. Two types of sensor probes are prepared-one is an FBG with 18 μm thick Al films, and the other is an FBG with 36 μm thick Al films-to compare the thickness effect on the detection sensitivity. These sensor probes are bonded on the surfaces of carbon fiber reinforced plastics composite specimens. In order to determine the strain sensitivity between the residual strain of the FBG sensor probe and the maximum strain of the composite specimen, tensile tests are performed by universal testing machine, under the loading-unloading test condition. The strain sensitivities of the probes, which have the Al thicknesses of 18 and 36 μm, are determined as 0.13 and 0.23, respectively.

  11. Design and testing of microfabricated surgical tools for large animal probe insertion

    Energy Technology Data Exchange (ETDEWEB)

    Jorgensen, Shelly [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-08-05

    Neural probes provide therapeutic stimulation for neuropsychiatric disorders or record neural activity to investigate the workings of the brain. Researchers utilize 6 mm long temporary silicon stiffeners attached with biodissolvable adhesive to insert flexible neural probes into rat brains, but increasing the probe length fivefold makes inserting large animal probes a significant challenge because of an increased potential for buckling. This study compared the insertion success rates of 6 mm and 30 mm long silicon stiffeners that were 80 μm wide and 30 μm thick, and ascertained the material thickness and modulus of elasticity that would provide successful insertion for a 30 mm probe. Using a microdrive, stiffeners were inserted into an agarose brain phantom at controlled insertion speeds while being video-recorded. Twenty-five percent of the 30 mm silicon stiffeners fully inserted at speeds approximately four times higher than the target rate of 0.13 mm/s, while 100 percent of the 6 mm silicon stiffeners inserted successfully at target speed. Critical buckling loads (Pcr) were calculated for the 6 mm and 30 mm silicon stiffeners, and for 30 mm diamond and tungsten stiffeners, with thicknesses varying from 30-80 μm. Increasing the thickness of the material by 10 μm, 20 μm and 30 μm improved the Pcr by 2.4, 4.7 and 8.2 times, respectively, independent of the material, and substituting diamond for silicon multiplied the buckling capacity by 5.0 times. Stiffeners made of silicon for large animal probe insertion are not strong enough to withstand buckling upon insertion without a significant increase in thickness. Replacing silicon with diamond and increasing the thickness of the stiffener to 50 μm would afford a stiffener with the same Pcr capacity as the 6 mm silicon stiffener that had a 100 percent insertion success rate. Experiments should continue with diamond to determine a minimum thickness that will ensure successful

  12. A sensitive DNA biosensor based on a facile sulfamide coupling reaction for capture probe immobilization

    International Nuclear Information System (INIS)

    Wang, Qingxiang; Ding, Yingtao; Gao, Feng; Jiang, Shulian; Zhang, Bin; Ni, Jiancong; Gao, Fei

    2013-01-01

    Graphical abstract: A novel DNA biosensor was fabricated through a facile sulfamide coupling reaction between probe DNA and the sulfonic dye of 1-amino-2-naphthol-4-sulfonic acid that electrodeposited on a glassy carbon electrode. -- Highlights: •A versatile sulfonic dye of ANS was electrodeposited on a GCE. •A DNA biosensor was fabricated based on a facile sulfamide coupling reaction. •High probe DNA density of 3.18 × 10 13 strands cm −2 was determined. •A wide linear range and a low detection limit were obtained. -- Abstract: A novel DNA biosensor was fabricated through a facile sulfamide coupling reaction. First, the versatile sulfonic dye molecule of 1-amino-2-naphthol-4-sulfonate (AN-SO 3 − ) was electrodeposited on the surface of a glassy carbon electrode (GCE) to form a steady and ordered AN-SO 3 − layer. Then the amino-terminated capture probe was covalently grafted to the surface of SO 3 − -AN deposited GCE through the sulfamide coupling reaction between the amino groups in the probe DNA and the sulfonic groups in the AN-SO 3 − . The step-by-step modification process was characterized by electrochemistry and attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy. Using Ru(NH 3 ) 6 3+ as probe, the probe density and the hybridization efficiency of the biosensor were determined to be 3.18 × 10 13 strands cm −2 and 86.5%, respectively. The hybridization performance of the biosensor was examined by differential pulse voltammetry using Co(phen) 3 3+/2+ (phen = 1,10-phenanthroline) as the indicator. The selectivity experiments showed that the biosensor presented distinguishable response after hybridization with the three-base mismatched, non-complementary and complementary sequences. Under the optimal conditions, the oxidation peak currents of Co(phen) 3 3+/2+ increased linearly with the logarithm values of the concentration of the complementary sequences in the range from 1.0 × 10 −13 M to 1.0 × 10 −8 M with

  13. Probing cardiac metabolism by hyperpolarized 13C MR using an exclusively endogenous substrate mixture and photo-induced nonpersistent radicals

    DEFF Research Database (Denmark)

    Bastiaansen, Jessica A M; Yoshihara, Hikari A I; Capozzi, Andrea

    2018-01-01

    dissolved, and the radical-free hyperpolarized solution was rapidly transferred into an injection pump located inside a 9.4T scanner. The hyperpolarized solution was injected in healthy rats to measure cardiac metabolism in vivo. Ultraviolet irradiation created nonpersistent radicals in a mixture containing......To probe the cardiac metabolism of carbohydrates and short chain fatty acids simultaneously in vivo following the injection of a hyperpolarized 13 C-labeled substrate mixture prepared using photo-induced nonpersistent radicals. Droplets of mixed [1-13 C]pyruvic and [1-13 C]butyric acids were frozen...... into glassy beads in liquid nitrogen. Ethanol addition was investigated as a means to increase the polarization level. The beads were irradiated with ultraviolet light and the radical concentration was measured by ESR spectroscopy. Following dynamic nuclear polarization in a 7T polarizer, the beads were...

  14. Purification of bacteriophage M13 by anion exchange chromatography.

    Science.gov (United States)

    Monjezi, Razieh; Tey, Beng Ti; Sieo, Chin Chin; Tan, Wen Siang

    2010-07-01

    M13 is a non-lytic filamentous bacteriophage (phage). It has been used widely in phage display technology for displaying foreign peptides, and also for studying macromolecule structures and interactions. Traditionally, this phage has been purified by cesium chloride (CsCl) density gradient ultracentrifugation which is highly laborious and time consuming. In the present study, a simple, rapid and efficient method for the purification of M13 based on anion exchange chromatography was established. A pre-packed SepFast Super Q column connected to a fast protein liquid chromatography (FPLC) system was employed to capture released phages in clarified Escherichia coli fermented broth. An average yield of 74% was obtained from a packed bed mode elution using citrate buffer (pH 4), containing 1.5 M NaCl at 1 ml/min flow rate. The purification process was shortened substantially to less than 2 h from 18 h in the conventional ultracentrifugation method. SDS-PAGE revealed that the purity of particles was comparable to that of CsCl gradient density ultracentrifugation method. Plaque forming assay showed that the purified phages were still infectious. Copyright 2010 Elsevier B.V. All rights reserved.

  15. The interaction of M13 coat protein with lipid bilayers : a spectroscopic study

    NARCIS (Netherlands)

    Sanders, J.C.

    1992-01-01

    In this thesis a small part of the reproductive cycle of the M13 bacteriophage is studied in more detail, namely the interaction of the major coat protein (MW 5240) with lipid bilayers. During the infection process is the major coat protein of M13 bacteriophage stored in the cytoplasm

  16. Factors Influencing Pitot Probe Centerline Displacement in a Turbulent Supersonic Boundary Layer

    Science.gov (United States)

    Grosser, Wendy I.

    1997-01-01

    When a total pressure probe is used for measuring flows with transverse total pressure gradients, a displacement of the effective center of the probe is observed (designated Delta). While this phenomenon is well documented in incompressible flow and supersonic laminar flow, there is insufficient information concerning supersonic turbulent flow. In this study, three NASA Lewis Research Center Supersonic Wind Tunnels (SWT's) were used to investigate pitot probe centerline displacement in supersonic turbulent boundary layers. The relationship between test conditions and pitot probe centerline displacement error was to be determined. For this investigation, ten circular probes with diameter-to-boundary layer ratios (D/delta) ranging from 0.015 to 0.256 were tested in the 10 ft x 10 ft SWT, the 15 cm x 15 cm SWT, and the 1 ft x 1 ft SWT. Reynolds numbers of 4.27 x 10(exp 6)/m, 6.00 x 10(exp 6)/in, 10.33 x 10(exp 6)/in, and 16.9 x 10(exp 6)/m were tested at nominal Mach numbers of 2.0 and 2.5. Boundary layer thicknesses for the three tunnels were approximately 200 mm, 13 mm, and 30 mm, respectively. Initial results indicate that boundary layer thickness, delta, and probe diameter, D/delta play a minimal role in pitot probe centerline offset error, Delta/D. It appears that the Mach gradient, dM/dy, is an important factor, though the exact relationship has not yet been determined. More data is needed to fill the map before a conclusion can be drawn with any certainty. This research provides valuable supersonic, turbulent boundary layer data from three supersonic wind tunnels with three very different boundary layers. It will prove a valuable stepping stone for future research into the factors influencing pitot probe centerline offset error.

  17. Detection and quantitative analysis of actin mRNA by in situ hybridization with an oligodeoxynucleotide probe

    International Nuclear Information System (INIS)

    Taneja, K.; Singer, R.

    1987-01-01

    In situ hybridization is a useful method for localizing specific nucleic acid sequences intracellularly and for studying regulation of gene expression. Recently synthetic oligonucleotides have been successfully used as probes in this technique. Since they can be made easily to specific nucleic acid regions, they may be the best approach for analysis of a gene family of highly conserved sequences. They have analyzed these probes for the development of an in situ hybridization method. Oligonucleotides were made to different regions of chick beta-actin mRNA and used for detection of these sequences in a culture of chicken fibroblasts and myoblasts. They found that synthetic DNAs have different efficiencies of hybridization, indicating that not all target sequences are equivalent. They have investigated in detail a particular probe to the actin mRNA coding region and have optimized hybridization parameters. When hybridization was quantitated it was found that an oligonucleotide end labelled with 35 S or 32 P was capable of detecting several thousand messages per cell with a signal-to-noise ratio of 10:1. In situ hybridization confirmed the specificity of the hybridization as well as the background level. Increase in the number of oligonucleotides used should increase the signal-to-noise ratio-proportionately. Under particular circumstances the specificity of oligonucleotides make them an important reagent for in situ hybridization

  18. Prognostic significance of CDH13 hypermethylation and mRNA in NSCLC

    Directory of Open Access Journals (Sweden)

    Xue R

    2014-10-01

    Full Text Available Ruilin Xue,1 Cuili Yang,1 Fang Zhao,2 Dejia Li1 1Global Health Institute, School of Public Health, 2Zhongnan Hospital, Wuhan University, Wuhan, People's Republic of ChinaAbstract: Aberrant methylation of CpG dinucleotides is a commonly observed epigenetic modification in human cancer. Thus, detection of aberrant gene promoter methylation as a tool for diagnosis of tumors or as a prognostic marker has been widely described for many types of cancers, including nonsmall cell lung cancer (NSCLC. Emerging evidence indicates that CDH13 is a candidate tumor suppressor in several types of human tumors, including NSCLC. However, the correlation between CDH13 hypermethylation and clinicopathological characteristics of NSCLC remains unclear. In the current study, we conducted a systematic review and meta-analysis to quantitatively evaluate the effects of CDH13 hypermethylation on the incidence of NSCLC and clinicopathological characteristics. Final analysis of 803 NSCLC patients from eleven eligible studies was performed. CDH13 hypermethylation was observed to be significantly higher in NSCLC than in normal lung tissue, with the pooled odds ratio (OR from seven studies including 448 NSCLC and 345 normal lung tissue (OR, 7.85; 95% confidence interval, 5.12–12.03; P<0.00001. CDH13 hypermethylation was also associated with pathological types. The pooled OR was obtained from four studies, including 111 squamous cell carcinoma and 106 adenocarcinoma (OR, 0.35; 95% confidence interval, 0.19–0.66; P=0.001, which indicated that CDH13 hypermethylation plays a more important role in the pathogenesis of adenocarcinoma. NSCLC with CDH13 hypermethylation was found more frequently in poorly differentiated NSCLC patients. NSCLC patients with CDH13 hypermethylation had a lower survival rate than those without CDH13 hypermethylation. In addition, CDH13 mRNA high expression was found to correlate with better overall survival for all NSCLC patients followed for 20 years

  19. Application of synthetic DNA probes to the analysis of DNA sequence variants in man

    International Nuclear Information System (INIS)

    Wallace, R.B.; Petz, L.D.; Yam, P.Y.

    1986-01-01

    Oligonucleotide probes provide a tool to discriminate between any two alleles on the basis of hybridization. Random sampling of the genome with different oligonucleotide probes should reveal polymorphism in a certain percentage of the cases. In the hope of identifying polymorphic regions more efficiently, we chose to take advantage of the proposed hypermutability of repeated DNA sequences and the specificity of oligonucleotide hybridization. Since, under appropriate conditions, oligonucleotide probes require complete base pairing for hybridization to occur, they will only hybridize to a subset of the members of a repeat family when all members of the family are not identical. The results presented here suggest that oligonucleotide hybridization can be used to extend the genomic sequences that can be tested for the presence of RFLPs. This expands the tools available to human genetics. In addition, the results suggest that repeated DNA sequences are indeed more polymorphic than single-copy sequences. 28 references, 2 figures

  20. RF compensation of single Langmuir probe in low density helicon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Soumen, E-mail: soumen@ipr.res.in; Chattopadhyay, Prabal K.; Ghosh, Joydeep; Bora, Dhiraj

    2016-11-15

    Highlights: • Appropriate density and temperature measurement with Langmuir probe in RF Eenvironment. • Necessity of large auxiliary electrode for RF compensation at low densities (∼10{sup 16} m{sup −3}). • Measured two temperature electrons in low pressure helicon antenna produced RF plasma. • Tail electrons are localized only at off-axis in our cylindrical plasma system. - Abstract: Interpretations of Single Langmuir probe measurements in electrode-less radio frequency (RF) plasmas are noteworthy tricky and require adequate compensation of RF. Conventional RF compensation technique is limited only at high density (>10{sup 17} m{sup −3}) RF plasmas. RF compensation of single Langmuir probe at low density RF plasmas (∼10{sup 16} m{sup −3}) is presented in this paper. In RF driven plasmas, where the RF voltage is high (∼50 V) and density is in the range (∼10{sup 16} m{sup −3}), the primary RF compensation condition (Z{sub ck} > >Z{sub sh}) is very difficult to fulfill, because of high sheath impedance (Z{sub sh}) at 13.56 MHz and the construction limitation of a self-resonant tiny chock (Z{sub ck}) with very high impedance. Introducing a large auxiliary electrode (A{sub x}), (A{sub x} >>> A{sub p}), close to the small Langmuir probe (A{sub p}) tip, connected in parallel with probe via a coupling capacitor (C{sub cp}), significantly reduces the effective sheath impedance (Z{sub sh}) and allows probe bias to follow the RF oscillation. Dimensional requirements of the auxiliary electrode and the role of suitable coupling capacitor are discussed in this paper. Observations show proper compensation leads to estimation of more positive floating potentials and lower electron temperatures compared to uncompensated probe. The electron energy probability function (EEPF) is also obtained by double differentiating the collected current with respect to the applied bias voltage using an active analog circuit.

  1. Synthesis, Characterizations and Investigation of Electrochemical Behaviours of 4-[(2-Hydroxyphenyliminomethyl]benzene-1,3-diol

    Directory of Open Access Journals (Sweden)

    Aysen D. Mulazimoglu

    2009-01-01

    Full Text Available This Schiff base ligand, 4-[(2-hydroxyphenylimino methyl]benzene-1,3-diol (HIBD was synthesized by reaction of 2-aminophenol and 2,4-dihydroxybenzaldehyde. The ligand was characterized by elemental analysis, FT-IR and 1H-NMR. Electrochemical behaviors were investigated on the glassy carbon electrode (GC surface with cyclic voltammetry (CV. The modification of HIBD on the GC was performed in +0.3 V and +2,8 V potential range using 100 mV s-1 scanning rate having 5 cycle. For the characterization of the modified surfaces 1 mM ferrocene redox probe in 0,1 M tetrabutylammonium tetrafluoroborate (TBATFB and 1 mM ferricyanide redox probe in 0.1 M H2SO4 were used.

  2. Apelin-13 enhances arcuate POMC neuron activity via inhibiting M-current.

    Directory of Open Access Journals (Sweden)

    Dong Kun Lee

    Full Text Available The hypothalamus is a key element of the neural circuits that control energy homeostasis. Specific neuronal populations within the hypothalamus are sensitive to a variety of homeostatic indicators such as circulating nutrient levels and hormones that signal circulating glucose and body fat content. Central injection of apelin secreted by adipose tissues regulates feeding and glucose homeostasis. However, the precise neuronal populations and cellular mechanisms involved in these physiological processes remain unclear. Here we examine the electrophysiological impact of apelin-13 on proopiomelanocortin (POMC neuron activity. Approximately half of POMC neurons examined respond to apelin-13. Apelin-13 causes a dose-dependent depolarization. This effect is abolished by the apelin (APJ receptor antagonist. POMC neurons from animals pre-treated with pertussis toxin still respond to apelin, whereas the Gβγ signaling inhibitor gallein blocks apelin-mediated depolarization. In addition, the effect of apelin is inhibited by the phospholipase C and protein kinase inhibitors. Furthermore, single-cell qPCR analysis shows that POMC neurons express the APJ receptor, PLC-β isoforms, and KCNQ subunits (2, 3 and 5 which contribute to M-type current. Apelin-13 inhibits M-current that is blocked by the KCNQ channel inhibitor. Therefore, our present data indicate that apelin activates APJ receptors, and the resultant dissociation of the Gαq heterotrimer triggers a Gβγ-dependent activation of PLC-β signaling that inhibits M-current.

  3. On the truncation of the azimuthal mode spectrum of high-order probes in probe-corrected spherical near-field antenna measurements

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Laitinen, Tommi

    2011-01-01

    Azimuthal mode (m mode) truncation of a high-order probe pattern in probe-corrected spherical near-field antenna measurements is studied in this paper. The results of this paper provide rules for appropriate and sufficient m-mode truncation for non-ideal first-order probes and odd-order probes wi...

  4. Single, 14-Day, and 13-Week Repeated Dose Toxicity Studies of Daily Oral Gelidium elegans Extract Administration to Rats

    Directory of Open Access Journals (Sweden)

    Jia Choi

    2018-01-01

    Full Text Available Gelidium elegans extract (GEE is derived from a red alga from the Asia–Pacific region, which has antioxidant, anti-adipogenic, and anti-hyperglycemic effects. However, detailed studies of the toxicology of GEE have not been performed. We evaluated the single oral dose toxicity of GEE in male and female Sprague-Dawley (CD rats. GEE did not cause deaths or have toxic effects at dosages of 5000 mg/kg/day, although compound-colored stools and diarrhea were observed in both sexes, which lasted <2 days. Therefore, the LD50 of GEE is likely to be >5000 mg/kg. We next evaluated the repeated oral dose toxicity of GEE in CD rats over 14 days and 13 weeks. GEE did not induce any significant toxicological changes in either sex at 2000 mg/kg/day. Repeated oral dose toxicity studies showed no adverse effects, in terms of clinical signs, mortality, body mass, food consumption, ophthalmic examination, urinalysis, hematology, serum biochemistry, necropsy, organ masses, or histopathology, at dosages of 500, 1000, or 2000 mg/kg/day. The no observed adverse effect level (NOAEL for GEE is thus likely to be >2000 mg/kg/day, and no pathology was identified in potential target organs. Therefore, this study indicates that repeated oral dosing with GEE is safe in CD rats.

  5. Doped zinc sulfide quantum dots based phosphorescence turn-off/on probe for detecting histidine in biological fluid

    Energy Technology Data Exchange (ETDEWEB)

    Bian, Wei [School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan 030006 (China); School of Basic Medical Science, Shanxi Medical University, Taiyuan 030001 (China); Wang, Fang [School of Basic Medical Science, Shanxi Medical University, Taiyuan 030001 (China); Wei, Yanli; Wang, Li; Liu, Qiaoling; Dong, Wenjuan [School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan 030006 (China); Shuang, Shaomin, E-mail: smshuang@sxu.edu.cn [School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan 030006 (China); Choi, Martin M.F., E-mail: mmfchoi@gmail.com [Partner State Key Laboratory of Environmental and Biological Analysis, and Department of Chemistry, Hong Kong Baptist University, 224 Waterloo Road, Kowloon Tong, Hong Kong SAR (China)

    2015-01-26

    Highlights: • A turn-on phosphorescence quantum dots probe for histidine is fabricated. • High sensitivity, good selectivity and low interference are achieved. • Histidine in urine samples can be easily detected by the phosphorescence probe. - Abstract: We report a turn-on phosphorescence probe for detection of histidine based on Co{sup 2+}-adsorbed N-acetyl-L-cysteine (NAC) capped Mn: ZnS quantum dots (QDs) which is directly synthesized by the hydrothermal method. The phosphorescence of NAC-Mn: ZnS QDs is effectively quenched by Co{sup 2+} attributing to the adsorption of Co{sup 2+} onto the surface of QDs with a concomitant in suppressing the recombination process of hole and electron of QDs. The phosphorescence of Co{sup 2+}-adsorbed NAC-Mn: ZnS QDs can be recovered by binding of Co{sup 2+} with histidine. The quenching and regeneration of the phosphorescence of NAC-Mn: ZnS QDs have been studied in detail. The as-prepared QDs-based probe is applied to determine histidine with a linear range of 1.25–30 μM and a detection limit of 0.74 μM. The relative standard deviation for eleven repeat detections of 20 μM histidine is 0.65%. Co{sup 2+}-adsorbed NAC-Mn: ZnS QDs show high sensitivity and good selectivity to histidine over other amino acids, metal ions and co-existing substances. The proposed QDs probe has been successfully applied to determination of histidine in human urine samples with good recoveries of 98.5–103%.

  6. Significant molecular and systemic adaptations after repeated sprint training in hypoxia.

    Directory of Open Access Journals (Sweden)

    Raphael Faiss

    Full Text Available While intermittent hypoxic training (IHT has been reported to evoke cellular responses via hypoxia inducible factors (HIFs but without substantial performance benefits in endurance athletes, we hypothesized that repeated sprint training in hypoxia could enhance repeated sprint ability (RSA performed in normoxia via improved glycolysis and O(2 utilization. 40 trained subjects completed 8 cycling repeated sprint sessions in hypoxia (RSH, 3000 m or normoxia (RSN, 485 m. Before (Pre- and after (Post- training, muscular levels of selected mRNAs were analyzed from resting muscle biopsies and RSA tested until exhaustion (10-s sprint, work-to-rest ratio 1:2 with muscle perfusion assessed by near-infrared spectroscopy. From Pre- to Post-, the average power output of all sprints in RSA was increased (p<0.01 to the same extent (6% vs 7%, NS in RSH and in RSN but the number of sprints to exhaustion was increased in RSH (9.4±4.8 vs. 13.0±6.2 sprints, p<0.01 but not in RSN (9.3±4.2 vs. 8.9±3.5. mRNA concentrations of HIF-1α (+55%, carbonic anhydrase III (+35% and monocarboxylate transporter-4 (+20% were augmented (p<0.05 whereas mitochondrial transcription factor A (-40%, peroxisome proliferator-activated receptor gamma coactivator 1α (-23% and monocarboxylate transporter-1 (-36% were decreased (p<0.01 in RSH only. Besides, the changes in total hemoglobin variations (Δ[tHb] during sprints throughout RSA test increased to a greater extent (p<0.01 in RSH. Our findings show larger improvement in repeated sprint performance in RSH than in RSN with significant molecular adaptations and larger blood perfusion variations in active muscles.

  7. Flow Cytometric Applicability of Fluorescent Vitality Probes on Phytoplankton

    NARCIS (Netherlands)

    Peperzak, L.; Brussaard, C.P.D.

    2011-01-01

    The applicability of six fluorescent probes (four esterase probes: acetoxymethyl ester of Calcein [Calcein-AM], 5-chloromethylfluorescein diacetate [CMFDA], fluorescein diacetate [FDA], and 2',7'-dichlorofluorescein diacetate [H(2)DCFDA]; and two membrane probes: bis-(1,3-dibutylbarbituric acid)

  8. Characterization of the peripheral blood transcriptome in a repeated measures design using a panel of healthy individuals

    DEFF Research Database (Denmark)

    De Boever, Patrick; Wens, Britt; Forcheh, Anyiawung Chiara

    2014-01-01

    A repeated measures microarray design with 22 healthy, non-smoking volunteers (aging 32. ±. 5. years) was set up to study transcriptome profiles in whole blood samples. The results indicate that repeatable data can be obtained with high within-subject correlation. Probes that could discriminate b...

  9. Assessment of the LV-S2 & LV-S3 Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A.; Antonio, Ernest J.; Flaherty, Julia E.; Amidan, Brett G.

    2014-09-30

    This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 1-2A exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The LV-C2, LV-S2, and LV-S3 exhaust stacks were tested together as a group (Test Group 1-2A). This report only covers the results of LV-S2 and LV-S3; LV-C2 will be reported on separately. Federal regulations1 require that a sampling probe be located in the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. 2 These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

  10. Development of Langmuir probe diagnostic system for 13.56 MHz plasma sources

    International Nuclear Information System (INIS)

    Ranjini, K.; Nabhiraj, P.Y.; Mallik, C.; Bhandari, R.K.

    2006-01-01

    A work on development of high brightness ion source has been started recently. Plasma parameters are strongly linked to the brightness of the ion beams produced from the ion sources. A self compensated Langmuir probe and related automation system for the measurement of plasma parameters is developed. This paper describes design of the probe, software, hardware and the results. (author)

  11. Measurement of 24-hr whole-body retention of sup(99m)Tc-MDP with a thyroid uptake probe

    International Nuclear Information System (INIS)

    Seto, Hikaru; Kakishita, Masao; Futatsuya, Ryusuke

    1981-01-01

    A new method for measurement of 24-hr whole-body retention (WBR) of sup(99m)Tc-MDP, using a thyroid uptake probe was established and its clinical significance was evaluated in various bone diseases. (1) Reproducibility of 24-hr WBR in 9 patients was very good. Correlation coefficient was 0.997 and coefficient of variability was only 1.83%. (2) Radiochemical purity of sup(99m)Tc-MDP was 97.8 +- 0.7% (n = 5), indicating no significant inter-lot variations. (3) 24-hr WBR of normal adult males (n = 5) was 30.0 +- 4.9%, which was significantly elevated compared to the reported sup(99m)Tc-HEDP WBR of 19.2 +- 1.7%. Whole-body retentions of chronic renal failure, metastatic bone disease and hyperthyroidism groups were significantly elevated compared to that of the normal group. However, WBR of steroid-induced osteoporotic group was significantly decreased. Based on these results, this thyroid uptake probe method was simple, reproducible and accurate to measure 24-hr WBR of sup(99m)Tc-MDP. Quantification of WBR of sup(99m)Tc-MDP was of great clinical value to diagnose metabolic bone disease and to follow-up metabolic and metastatic bone diseases. (author)

  12. Anterior prostate biopsy at initial and repeat evaluation: is it useful to detect significant prostate cancer?

    Directory of Open Access Journals (Sweden)

    Pietro Pepe

    2015-10-01

    Full Text Available ABSTRACT Purpose: Detection rate for anterior prostate cancer (PCa in men who underwent initial and repeat biopsy has been prospectively evaluated. Materials and Methods: From January 2013 to March 2014, 400 patients all of Caucasian origin (median age 63.5 years underwent initial (285 cases and repeat (115 cases prostate biopsy; all the men had negative digital rectal examination and the indications to biopsy were: PSA values > 10 ng/mL, PSA between 4.1-10 or 2.6-4 ng/mL with free/total PSA≤25% and ≤20%, respectively. A median of 22 (initial biopsy and 31 cores (repeat biopsy were transperineally performed including 4 cores of the anterior zone (AZ and 4 cores of the AZ plus 2 cores of the transition zone (TZ, respectively. Results: Median PSA was 7.9 ng/mL; overall, a PCa was found in 180 (45% patients: in 135 (47.4% and 45 (36% of the men who underwent initial and repeat biopsy, respectively. An exclusive PCa of the anterior zone was found in the 8.9 (initial biopsy vs 13.3% (repeat biopsy of the men: a single microfocus of cancer was found in the 61.2% of the cases; moreover, in 7 out 18 AZ PCa the biopsy histology was predictive of significant cancer in 2 (28.5% and 5 (71.5% men who underwent initial and repeat biopsy, respectively. Conclusions: However AZ biopsies increased detection rate for PCa (10% of the cases, the majority of AZ PCa with histological findings predictive of clinically significant cancer were found at repeat biopsy (about 70% of the cases.

  13. Distribution and evolution of repeated sequences in genomes of Triatominae (Hemiptera-Reduviidae inferred from genomic in situ hybridization.

    Directory of Open Access Journals (Sweden)

    Sebastian Pita

    Full Text Available The subfamily Triatominae, vectors of Chagas disease, comprises 140 species characterized by a highly homogeneous chromosome number. We analyzed the chromosomal distribution and evolution of repeated sequences in Triatominae genomes by Genomic in situ Hybridization using Triatoma delpontei and Triatoma infestans genomic DNAs as probes. Hybridizations were performed on their own chromosomes and on nine species included in six genera from the two main tribes: Triatomini and Rhodniini. Genomic probes clearly generate two different hybridization patterns, dispersed or accumulated in specific regions or chromosomes. The three used probes generate the same hybridization pattern in each species. However, these patterns are species-specific. In closely related species, the probes strongly hybridized in the autosomal heterochromatic regions, resembling C-banding and DAPI patterns. However, in more distant species these co-localizations are not observed. The heterochromatic Y chromosome is constituted by highly repeated sequences, which is conserved among 10 species of Triatomini tribe suggesting be an ancestral character for this group. However, the Y chromosome in Rhodniini tribe is markedly different, supporting the early evolutionary dichotomy between both tribes. In some species, sex chromosomes and autosomes shared repeated sequences, suggesting meiotic chromatin exchanges among these heterologous chromosomes. Our GISH analyses enabled us to acquire not only reliable information about autosomal repeated sequences distribution but also an insight into sex chromosome evolution in Triatominae. Furthermore, the differentiation obtained by GISH might be a valuable marker to establish phylogenetic relationships and to test the controversial origin of the Triatominae subfamily.

  14. Tevatron serial data repeater system

    International Nuclear Information System (INIS)

    Ducar, R.J.

    1981-01-01

    A ten megabit per second serial data repeater system has been developed for the 6.28km Tevatron accelerator. The repeaters are positioned at each of the thirty service buildings and accommodate control and abort system communications as well as distribution of the Tevatron time and energy clocks. The repeaters are transparent to the particular protocol of the transmissions. Serial data are encoded locally as unipolar two volt signals employing the self-clocking Manchester Bi-Phase code. The repeaters modulate the local signals to low-power bursts of 50 MHz rf carrier for the 260m transmission between service buildings. The repeaters also demodulate the transmission and restructure the data for local utilization. The employment of frequency discrimination techniques yields high immunity to the characteristic noise spectrum

  15. Design and development of a 3 axis magnetic field measurement facility using Hall probe

    International Nuclear Information System (INIS)

    Sahoo, Shantonu; Bhattacharyya, Sumantra; Chaddha, Niraj; Mishra, Santosh Kr.; Nandy, Partha P.; Nandi, Chinmay; Bhole, Rajendra B.; Pal, Sarbajit; Pal, Gautam

    2015-01-01

    A 3-axis drive system has been designed and developed in-house to measure the magnetic field with positional accuracy of 0.2 mm in a volume of 1.5 x 1.3 x 0.15 cubic-meter. Hall sensor based magnetometer is used to measure the magnetic field with a precision of 100 μT(1 Gauss). The drive of each axis has linear guide and zero backlash ball screw combination to achieve accurate movement of the hall probe with positional repeatability of +/- 0.2 micron per 50 mm. The hardware and software, also developed in-house, facilitate precise probe positioning and sophisticated visualization of field map. Dedicated microcontroller based motor controllers and encoder read-out cards for each axis have been developed. The facility is integrated with a rich touch-screen based intelligent GUI for automated scanning and data acquisition. This facility can be used for accurate magnetic field mapping of big dipole magnets, solenoids, etc. The facility has been tested successfully to characterize a Dipole Magnet designed for Radioactive Ion Beam (RIB) facility. (author)

  16. M13 multiple stellar populations seen with the eyes of Strömgren photometry

    Science.gov (United States)

    Savino, A.; Massari, D.; Bragaglia, A.; Dalessandro, E.; Tolstoy, E.

    2018-03-01

    We present a photometric study of M13 multiple stellar populations over a wide field of view, covering approximately 6.5 half-light radii, using archival Isaac Newton Telescope observations to build an accurate multiband Strömgren catalogue. The use of the Strömgren index cy permits us to separate the multiple populations of M13 on the basis of their position on the red giant branch. The comparison with medium and high resolution spectroscopic analysis confirms the robustness of our selection criterion. To determine the radial distribution of stars in M13, we complemented our data set with Hubble Space Telescope observations of the cluster core, to compensate for the effect of incompleteness affecting the most crowded regions. From the analysis of the radial distributions, we do not find any significant evidence of spatial segregation. Some residuals may be present in the external regions where we observe only a small number of stars. This finding is compatible with the short dynamical time-scale of M13 and represents, to date, one of the few examples of fully spatially mixed multiple populations in a massive globular cluster.

  17. Repeated exposure to cat urine induces complex behavioral, hormonal, and c-fos mRNA responses in Norway rats ( Rattus norvegicus)

    Science.gov (United States)

    Yin, Baofa; Gu, Chen; Lu, Yi; Hegab, Ibrahim M.; Yang, Shengmei; Wang, Aiqin; Wei, Wanhong

    2017-08-01

    Prey species show specific adaptations that allow recognition, avoidance, and defense against predators. This study was undertaken to investigate the processing of a chronic, life-threatening stimulus to Norway rats ( Rattus norvegicus). One hundred forty-four Norway rats were tested by repeated presentation of cat urine for 1 h at different days in a defensive withdrawal apparatus. Rats exposed to urine for short periods showed significantly larger defensive behavioral and medial hypothalamic c-fos messenger RNA (mRNA) responses than other groups. These defensive responses habituated shortly after the presentation of cat urine. Serum levels of adrenocorticotropic hormone and corticosterone increased significantly when animals were repeatedly exposed to cat urine. However, the hormonal responses took longer to habituate than the behavioral and molecular responses did. We conclude that the behavioral and c-fos mRNA responses are "primed" for habituation to repeated exposures to cat urine, while the hormonal responses show "resistance." The results support our hypothesis that the strongest anti-predator responses at three levels would occur during short-term exposure to cat urine and that these responses would subsequently disappear on prolonged exposure. This study assists understanding the way in which the different levels of defensive responses are integrated and react during chronic stress.

  18. Signal amplification of microRNAs with modified strand displacement-based cycling probe technology.

    Science.gov (United States)

    Jia, Huning; Bu, Ying; Zou, Bingjie; Wang, Jianping; Kumar, Shalen; Pitman, Janet L; Zhou, Guohua; Song, Qinxin

    2016-10-24

    Micro ribose nucleic acids (miRNAs) play an important role in biological processes such as cell differentiation, proliferation and apoptosis. Therefore, miRNAs are potentially a powerful marker for monitoring cancer and diagnosis. Here, we present sensitive signal amplification for miRNAs based on modified cycling probe technology with strand displacement amplification. miRNA was captured by the template coupled with beads, and then the first cycle based on SDA was repeatedly extended to the nicking end, which was produced by the extension reaction of miRNA. The products generated by SDA are captured by a molecular beacon (MB), which is designed to initiate the second amplification cycle, with a similar principle to the cycling probe technology (CPT), which is based on repeated digestion of the DNA-RNA hybrid by the RNase H. After one sample enrichment and two steps of signal amplification, 0.1 pM of let-7a can be detected. The miRNA assay exhibits a great dynamic range of over 100 orders of magnitude and high specificity to clearly discriminate a single base difference in miRNA sequences. This isothermal amplification does not require any special temperature control instrument. The assay is also about signal amplification rather than template amplification, therefore minimising contamination issues. In addition, there is no need for the reverse transcription (RT) process. Thus the amplification is suitable for miRNA detection.

  19. Radionuclide imaging of small-cell lung cancer (SCLC) using 99mTc-labeled neurotensin peptide 8-13

    International Nuclear Information System (INIS)

    Zhang Kaijun; An Rui; Gao Zairong; Zhang Yongxue; Aruva, Mohan R.

    2006-01-01

    Objectives: To prepare 99m technetium ( 99m Tc)-labeled neurotensin (NT) peptide and to evaluate the feasibility of imaging oncogene NT receptors overexpressed in human small-cell lung cancer (SCLC) cells. Methods: The NT analogue (Nα-His)Ac-NT(8-13) was synthesized such that histidine was attached at the N-terminus. The analogue was labeled with [ 99m Tc(H 2 O) 3 (CO) 3 ] at pH 7. 99m Tc-(Nα-His)Ac-NT(8-13) in vitro stability was determined by challenging it with 100 times the molar excess of DTPA, human serum albumin (HSA) and cysteine. The affinity, 99m Tc-(Nα-His)Ac-NT(8-13) binding to SCLC cell line NCI-H446, was studied in vitro. Biodistribution and imaging with 99m Tc-(Nα-His)Ac-NT(8-13) were performed at 4 and 12 h postinjection, and tissue distribution and imaging after receptor blocking were carried out at 4 h in nude mice bearing human SCLC tumor. Blood clearance was determined in normal mice. Results: The affinity constant (K d ) of 99m Tc-(Nα-His)Ac-NT(8-13) to SCLC cells was 0.56 nmol/L. When challenged with 100 times the molar excess of DTPA, HSA or cysteine, more than 97±1.8% radioactivity remained as 99m Tc-(Nα-His)Ac-NT(8-13). Tumor-to-muscle ratio was 3.35±1.01 at 4 h and 4.20±1.35 at 12 h postinjection. The excretory route of 99m Tc-(Nα-His)Ac-NT(8-13) was chiefly through the renal pathway. In the receptor-blocking group treated with unlabeled (Nα-His)Ac-NT(8-13), tumor-to-muscle ratio at 4 h was 1.25±0.55. Conclusion: The results suggest that 99m Tc-(Nα-His)Ac-NT(8-13) specifically binds to the SCLC cells and made 99m Tc-(Nα-His)Ac-NT(8-13) a desirable compound for further studies in planar or SPECT imaging of oncogene receptors overexpressed in SCLC cells

  20. DARC PLURIDATA system: the /sup 13/C-N. M. R. data bank

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, J E; Bonnet, J C [Paris-7 Univ., 75 (France)

    1979-09-15

    The capabilities of the DARC system are discussed and illustrated by the storage and retrieval functions of the /sup 13/C-N.M.R. data bank of the DARC PLURIDATA system. The data covered by the bank, as well as the input stream to the bank and validation of the spectra, are described. Particular stress is laid on the DARC structural retrieval system, which illustrates the interactive interrogration of a chemical bank by means of the structural diagram of a molecule, i.e. the universal language in chemistry. The potential of the /sup 13/C-N.M.R. data bank in computer-aided structural elucidation is outlined.

  1. A study on radiographic repeat rate data of several hospitals in Jeddah

    International Nuclear Information System (INIS)

    Al-Malki, M.A.; Abulfaraj, W.H.; Bhuiyan, S.I.; Kinsara, A.A.

    2003-01-01

    Radiographic repeat rate data in diagnostic radiology in King Fahad Hospital (KFH), King Abdulaziz Hospital (KAH), and Maternity and Children Hospital (MCH) in Jeddah, Saudi Arabia, have been studied. The study provided valuable information to suggest preventive measures to reduce repeats. The variables included in the study are exposure techniques, examination types, total number of films used, number of films repeated, the film sizes, gender, the age groups of the patients, and reason for repetition. The total number of examinations in all three hospitals is 6001 using 8887 films on 5412 patients. The average repeat rate was 7.93%, where the individual hospital repeat rates were 9.57% in the MCH, 7.84% in KAH and 7.44% in KFH. The repeat rate for children and infants was found to be undesirable. The quality assurance (QA) programme can effectively reduce the unnecessary exposure and can identify the cause of the exposure. The overexposure, underexposure and position fault were the foremost contributors for repeats and constitute 32.91%, 28.94% and 22.98% of the total respectively. The QA study identified that human error and equipment malfunction are the major contributors to these causes of repeats. The highest repetition rate was for pelvis, 13.64%, followed by skull, 11.59%, and abdomen, 10.41%. It is estimated that the total area of wasted film in all three hospitals is 74.3 m 2 . As per the average repeat rate, the cost of repeat films in the entire kingdom per year has been projected to be about US$1.82 million (SR 6.83 million) in the government hospitals only. Based on the findings of this study a set of recommendations have been prescribed for the radiology department to reduce the repeat rate and to improve the safety culture. (author)

  2. A study on radiographic repeat rate data of several hospitals in Jeddah

    Energy Technology Data Exchange (ETDEWEB)

    Al-Malki, M.A.; Abulfaraj, W.H.; Bhuiyan, S.I.; Kinsara, A.A

    2003-07-01

    Radiographic repeat rate data in diagnostic radiology in King Fahad Hospital (KFH), King Abdulaziz Hospital (KAH), and Maternity and Children Hospital (MCH) in Jeddah, Saudi Arabia, have been studied. The study provided valuable information to suggest preventive measures to reduce repeats. The variables included in the study are exposure techniques, examination types, total number of films used, number of films repeated, the film sizes, gender, the age groups of the patients, and reason for repetition. The total number of examinations in all three hospitals is 6001 using 8887 films on 5412 patients. The average repeat rate was 7.93%, where the individual hospital repeat rates were 9.57% in the MCH, 7.84% in KAH and 7.44% in KFH. The repeat rate for children and infants was found to be undesirable. The quality assurance (QA) programme can effectively reduce the unnecessary exposure and can identify the cause of the exposure. The overexposure, underexposure and position fault were the foremost contributors for repeats and constitute 32.91%, 28.94% and 22.98% of the total respectively. The QA study identified that human error and equipment malfunction are the major contributors to these causes of repeats. The highest repetition rate was for pelvis, 13.64%, followed by skull, 11.59%, and abdomen, 10.41%. It is estimated that the total area of wasted film in all three hospitals is 74.3 m{sup 2}. As per the average repeat rate, the cost of repeat films in the entire kingdom per year has been projected to be about US$1.82 million (SR 6.83 million) in the government hospitals only. Based on the findings of this study a set of recommendations have been prescribed for the radiology department to reduce the repeat rate and to improve the safety culture. (author)

  3. Multiple high-intensity focused ultrasound probes for kidney-tissue ablation.

    Science.gov (United States)

    Häcker, Axel; Chauhan, Sunita; Peters, Kristina; Hildenbrand, Ralf; Marlinghaus, Ernst; Alken, Peter; Michel, Maurice Stephan

    2005-10-01

    To investigate kidney-tissue ablation by high-intensity focused ultrasound (HIFU) using multiple and single probes. Ultrasound beams (1.75 MHz) produced by a piezoceramic element (focal distance 80 mm) were focused at the center of renal parenchyma. One of the three probes (mounted on a jig) could also be used for comparison with a single probe at comparable power ratings. Lesion dimensions were examined in perfused and unperfused ex vivo porcine kidneys at different power levels (40, 60, and 80 W) and treatment times (4, 6, and 8 seconds). At identical power levels, the lesions induced by multiple probes were larger than those induced by a single probe. Lesion size increased with increasing pulse duration and generator power. The sizes and shapes of the lesions were predictably repeatable in all samples. Lesions in perfused kidneys were smaller than those in unperfused kidneys. Ex vivo, kidney-tissue ablation by means of multiple HIFU probes offers significant advantages over single HIFU probes in respect of lesion size and formation. These advantages need to be confirmed by tests in vivo at higher energy levels.

  4. Hot HB Stars in Globular Clusters: Physical Parameters and Consequences for Theory. VI; The Second Parameter Pair M 3 and M 13

    Science.gov (United States)

    Moehler, S.; Landsman, W. B.; Sweigart, A. V.; Grundahl, F.

    2003-01-01

    We present the results of spectroscopic analyses of hot horizontal branch (HB) stars in M 13 and M 3, which form a famous "second parameter" pair. F rom the spectra and Stromgren photometry we derived - for the first time in M 13 - atmospheric parameters (effective temperature and surface gravity). For stars with Stromgren temperatures between 10,000 and 12,000 K we found excellent agreement between the atmospheric parameters derived from Stromgren photometry and those derived from Balmer line profile fits. However, for cooler stars there is a disagreement in the parameters derived by the two methods, for which we have no satisfactory explanation. Stars hotter than 12,000 K show evidence for helium depletion and iron enrichment, both in M 3 and M 13. Accounting for the iron enrichment substantially improves the agreement with canonical evolutionary models, although the derived gravities and masses are still somewhat too low. This remaining discrepancy may be an indication that scaled-solar metal-rich model atmospheres do not adequately represent the highly non-solar abundance ratios found in blue HB stars affected by diffusion. We discuss the effects of an enhancement in the envelope helium abundance on the atmospheric parameters of the blue HB stars, as might be caused by deep mixing on the red giant branch or primordial pollution from an earlier generation of intermediate mass asymptotic giant branch stars. Key words. Stars: atmospheres - Stars: evolution - Stars: horizontal branch - Globular clusters: individual: M 3 - Globular clusters: individual: M 13

  5. Optimisation of 1.3 μm strained-layer semiconductor lasers

    International Nuclear Information System (INIS)

    Pacey, C.

    1999-03-01

    The objectives of the research undertaken have been to investigate the properties of semiconductor lasers operating at around 1.3 μm. The aim of the investigation is to suggest modifications which give rise to improved operating characteristics especially in the high temperature (approaching 85 deg. C) range. The investigation can be divided into 2 sections: a theoretical approach and an experimental section. The theoretical study examined the performance of compressively strained InGaAsP/InP multiple quantum-well lasers emitting at 1.3 μm. in order to investigate the important factors and trends in the threshold current density and differential gain with strain, well width and well number. Structures with a fixed compressive strain of 1% but variable well width, and also with a fixed well width but variable strain from 0% to 1.4% have been considered. It has been found that there is little benefit to having compressive strains greater than 1%. For structures with a fixed 1% compressive strain and unstrained barriers, an optimum structure for lowest threshold current density and a high differential gain has been found to consist of six 35 A quantum-wells. In addition, compensated strain (CS) structures with compressive wells and tensile barriers have been examined. It is shown that the conduction band offset can be significantly increased and the valence band offset reduced in such structures, to give band-offset ratios comparable with aluminium based 1.3 μm devices. The gain calculations performed suggest that there is little degradation in the threshold carrier density or differential gain due to these alterations in the band offsets; and hence a better laser performance is expected due to a reduction in thermal leakage currents due to the improved electron confinement. The experimental study concentrates on looking at certain key design parameters to investigate their effect on the laser performance. These design parameters range from the number of quantum

  6. Study of a 13-weeks, Repeated, Intramuscular Dose, Toxicity Test of Sweet Bee Venom in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Hyunmin Kang

    2014-06-01

    Full Text Available Objectives:This study was performed to analyze a 13-week repeated dose toxicity test of Sweet Bee Venom (SBV extracted from bee venom and administered in Sprague-Dawley (SD rats. Methods:Male and female 5-week-old SD rats were treated once daily with SBV (high-dosage group: 0.28 mg/kg; medium-dosage group: 0.14 mg/kg; or low-dosage group: 0.07 mg/kg for 13 weeks. Normal saline was administered to the control group in a similar manner (0.2 mL/kg. We conducted clinical observations, body weight measurements, ophthalmic examinations, urinalyses, hematology and biochemistry tests, and histological observations using hematoxylin and eosin (H&E staining to identify any abnormalities caused by the SBV treatment. Results:During this study, no mortality was observed in any of the experimental groups. Hyperemia and a movement disorder were observed around the area of in all groups that received SBV treatment, with a higher occurrence in rats treated with a higher dosage. Male rats receiving in the high-dosage group showed a significant decrease in weight during the treatment period. Compared to the control group, no significant changes in the ophthalmic parameters, the urine analyses, the complete blood cell count (CBC, and the biochemistry in the groups treated with SBV. Compared to the control group, some changes in organ weights were observed in the medium-and the high-dosage groups, but the low-dosage group showed no significant changes. Histological examination of thigh muscle indicated cell infiltration, inflammation, degeneration, and necrosis of muscle fiber, as well as fibrosis, in both the medium- and the high-dosage groups. Fatty liver change was observed in the periportal area of rats receiving medium and high dosages of SBV. No other organ abnormalities were observed. Conclusion:Our findings suggest that the No Observed Adverse Effect Level (NOAEL of SBV is approximately 0.07 mg/kg in male and female SD rats.

  7. Optimization of 1.3m InGaAsP/InP Electro-Absorption Modulator

    International Nuclear Information System (INIS)

    Wang Hui-Tao; Zhou Dai-Bing; Zhang Rui-Kang; Lu Dan; Zhao Ling-Juan; Zhu Hong-Liang; Wang Wei; Ji Chen

    2015-01-01

    We report the simulation and experimental results of 1.3m InGaAsP/InP multiple quantum well (MQW) electro-absorption modulators (EAMs). In this work, the quantum confined Stark effect of the EAM is systematically analyzed through the finite element method. An optimized structure of the 1.3m InGaAsP/InP QW EAM is proposed for applications in 100 G ethernet. Then 1.3m InGaAsP/InP EAMs with f_−_3 _d_B bandwidth of over 20 GHz and extinction ratio over 20 dB at 3 V bias voltage are demonstrated. (paper)

  8. A Miniature Four-Hole Probe for Measurement of Three-Dimensional Flow with Large Gradients

    Directory of Open Access Journals (Sweden)

    Ravirai Jangir

    2014-01-01

    Full Text Available A miniature four-hole probe with a sensing area of 1.284 mm2 to minimise the measurement errors due to the large pressure and velocity gradients that occur in highly three-dimensional turbomachinery flows is designed, fabricated, calibrated, and validated. The probe has good spatial resolution in two directions, thus minimising spatial and flow gradient errors. The probe is calibrated in an open jet calibration tunnel at a velocity of 50 m/s in yaw and pitch angles range of ±40 degrees with an interval of 5 degrees. The calibration coefficients are defined, determined, and presented. Sensitivity coefficients are also calculated and presented. A lookup table method is used to determine the four unknown quantities, namely, total and static pressures and flow angles. The maximum absolute errors in yaw and pitch angles are 2.4 and 1.3 deg., respectively. The maximum absolute errors in total, static, and dynamic pressures are 3.4, 3.9, and 4.9% of the dynamic pressures, respectively. Measurements made with this probe, a conventional five-hole probe and a miniature Pitot probe across a calibration section, demonstrated that the errors due to gradient and surface proximity for this probe are considerably reduced compared to the five-hole probe.

  9. GENETIC DIVERSITY OF TYPHA LATIFOLIA (TYPHACEAE) AND THE IMPACT OF POLLUTANTS EXAMINED WITH TANDEM-REPETITIVE DNA PROBES

    Science.gov (United States)

    Genetic diversity at variable-number-tandem-repeat (VNTR) loci was examined in the common cattail, Typha latifolia (Typhaceae), using three synthetic DNA probes composed of tandemly repeated "core" sequences (GACA, GATA, and GCAC). The principal objectives of this investigation w...

  10. Recognition memory probes affect what is remembered in schizophrenia.

    Science.gov (United States)

    Schwartz, Barbara L; Parker, Elizabeth S; Rosse, Richard B; Deutsch, Stephen I

    2009-05-15

    Cognitive psychology offers tools to localize the memory processes most vulnerable to disruption in schizophrenia and to identify how patients with schizophrenia best remember. In this research, we used the University of Southern California Repeatable Episodic Memory Test (USC-REMT; Parker, E.S., Landau, S.M., Whipple, S.C., Schwartz, B.L., 2004. Aging, recall, and recognition: A study on the sensitivity of the University of Southern California Repeatable Episodic Memory Test (USC-REMT). Journal of Clinical and Experimental Neuropsychology 26(3), 428-440.) to examine how two different recognition memory probes affect memory performance in patients with schizophrenia and matched controls. Patients with schizophrenia studied equivalent word lists and were tested by yes-no recognition and forced-choice recognition following identical encoding and storage conditions. Compared with controls, patients with schizophrenia were particularly impaired when tested by yes-no recognition relative to forced-choice recognition. Patients had greatest deficits on hits in yes-no recognition but did not exhibit elevated false alarms. The data point to the importance of retrieval processes in schizophrenia, and highlight the need for further research on ways to help patients with schizophrenia access what they have learned.

  11. Imaging optical probe for pressurized steam-water environment

    International Nuclear Information System (INIS)

    Donaldson, M.R.; Pulfrey, R.E.

    1979-01-01

    An air-cooled imaging optical probe, with an outside diameter of 25.4 mm, has been developed to provide high resolution viewing of flow regimes in a steam-water environment at 343 0 C and 15.2 MPa. The design study considered a 3-m length probe. A 0.3-m length probe prototype was fabricated and tested. The optical probe consists of a 3.5-mm diameter optics train surrounded by two coaxial coolant flow channels and two coaxial insulating dead air spaces. With air flowing through the probe at 5.7 g/s, thermal analysis shows that no part of the optics train will exceed 93 0 C when a 3-m length probe is immersed in a 343 0 C environment. Computer stress analysis plus actual tests show that the probe can operate successfully with conservative safety factors. The imaging optical probe was tested five times in the design environment at the semiscale facility at the INEL. Two-phase flow regimes in the high temperature, high pressure, steam-water blowdown and reflood experiments were recorded on video tape for the first time with the imaging optical probe

  12. Nine New Fluorescent Probes

    Science.gov (United States)

    Lin, Tsung-I.; Jovanovic, Misa V.; Dowben, Robert M.

    1989-06-01

    Absorption and fluorescence spectroscopic studies are reported here for nine new fluorescent probes recently synthesized in our laboratories: four pyrene derivatives with substituents of (i) 1,3-diacetoxy-6,8-dichlorosulfonyl, (ii) 1,3-dihydroxy-6,8-disodiumsulfonate, (iii) 1,3-disodiumsulfonate, and (iv) l-ethoxy-3,6,8-trisodiumsulfonate groups, and five [7-julolidino] coumarin derivatives with substituents of (v) 3-carboxylate-4-methyl, (vi) 3- methylcarboxylate, (vii) 3-acetate-4-methyl, (viii) 3-propionate-4-methyl, and (ix) 3-sulfonate-4-methyl groups. Pyrene compounds i and ii and coumarin compounds v and vi exhibit interesting absorbance and fluorescence properties: their absorption maxima are red shifted compared to the parent compound to the blue-green region, and the band width broadens considerably. All four blue-absorbing dyes fluoresce intensely in the green region, and the two pyrene compounds emit at such long wavelengths without formation of excimers. The fluorescence properties of these compounds are quite environment-sensitive: considerable spectral shifts and fluorescence intensity changes have been observed in the pH range from 3 to 10 and in a wide variety of polar and hydrophobic solvents with vastly different dielectric constants. The high extinction and fluorescence quantum yield of these probes make them ideal fluorescent labeling reagents for proteins, antibodies, nucleic acids, and cellular organelles. The pH and hydrophobicity-dependent fluorescence changes can be utilized as optical pH and/or hydrophobicity indicators for mapping environmental difference in various cellular components in a single cell. Since all nine probes absorb in the UV, but emit at different wavelengths in the visible, these two groups of compounds offer an advantage of utilizing a single monochromatic light source (e.g., a nitrogen laser) to achieve multi-wavelength detection for flow cytometry application. As a first step to explore potential application in

  13. Various mutations compensate for a deleterious lacZα insert in the replication enhancer of M13 bacteriophage.

    Directory of Open Access Journals (Sweden)

    Emily M Zygiel

    Full Text Available M13 and other members of the Ff class of filamentous bacteriophages have been extensively employed in myriad applications. The Ph.D. series of phage-displayed peptide libraries were constructed from the M13-based vector M13KE. As a direct descendent of M13mp19, M13KE contains the lacZα insert in the intergenic region between genes IV and II, where it interrupts the replication enhancer of the (+ strand origin. Phage carrying this 816-nucleotide insert are viable, but propagate in E. coli at a reduced rate compared to wild-type M13 phage, presumably due to a replication defect caused by the insert. We have previously reported thirteen compensatory mutations in the 5'-untranslated region of gene II, which encodes the replication initiator protein gIIp. Here we report several additional mutations in M13KE that restore a wild-type propagation rate. Several clones from constrained-loop variable peptide libraries were found to have ejected the majority of lacZα gene in order to reconstruct the replication enhancer, albeit with a small scar. In addition, new point mutations in the gene II 5'-untranslated region or the gene IV coding sequence have been spontaneously observed or synthetically engineered. Through phage propagation assays, we demonstrate that all these genetic modifications compensate for the replication defect in M13KE and restore the wild-type propagation rate. We discuss the mechanisms by which the insertion and ejection of the lacZα gene, as well as the mutations in the regulatory region of gene II, influence the efficiency of replication initiation at the (+ strand origin. We also examine the presence and relevance of fast-propagating mutants in phage-displayed peptide libraries.

  14. History, rare, and multiple events of mechanical unfolding of repeat proteins

    Science.gov (United States)

    Sumbul, Fidan; Marchesi, Arin; Rico, Felix

    2018-03-01

    Mechanical unfolding of proteins consisting of repeat domains is an excellent tool to obtain large statistics. Force spectroscopy experiments using atomic force microscopy on proteins presenting multiple domains have revealed that unfolding forces depend on the number of folded domains (history) and have reported intermediate states and rare events. However, the common use of unspecific attachment approaches to pull the protein of interest holds important limitations to study unfolding history and may lead to discarding rare and multiple probing events due to the presence of unspecific adhesion and uncertainty on the pulling site. Site-specific methods that have recently emerged minimize this uncertainty and would be excellent tools to probe unfolding history and rare events. However, detailed characterization of these approaches is required to identify their advantages and limitations. Here, we characterize a site-specific binding approach based on the ultrastable complex dockerin/cohesin III revealing its advantages and limitations to assess the unfolding history and to investigate rare and multiple events during the unfolding of repeated domains. We show that this approach is more robust, reproducible, and provides larger statistics than conventional unspecific methods. We show that the method is optimal to reveal the history of unfolding from the very first domain and to detect rare events, while being more limited to assess intermediate states. Finally, we quantify the forces required to unfold two molecules pulled in parallel, difficult when using unspecific approaches. The proposed method represents a step forward toward more reproducible measurements to probe protein unfolding history and opens the door to systematic probing of rare and multiple molecule unfolding mechanisms.

  15. Scanning vector Hall probe microscopy

    International Nuclear Information System (INIS)

    Cambel, V.; Gregusova, D.; Fedor, J.; Kudela, R.; Bending, S.J.

    2004-01-01

    We have developed a scanning vector Hall probe microscope for mapping magnetic field vector over magnetic samples. The microscope is based on a micromachined Hall sensor and the cryostat with scanning system. The vector Hall sensor active area is ∼5x5 μm 2 . It is realized by patterning three Hall probes on the tilted faces of GaAs pyramids. Data from these 'tilted' Hall probes are used to reconstruct the full magnetic field vector. The scanning area of the microscope is 5x5 mm 2 , space resolution 2.5 μm, field resolution ∼1 μT Hz -1/2 at temperatures 10-300 K

  16. Simple sequence repeat (SSR)-based genetic variability among ...

    African Journals Online (AJOL)

    The objective of this study was to compare if simple sequence repeat (SSR) markers could correctly identify peanut genotypes with difference in specific leaf weight (SLW) and relative water content (RWC). Four peanut genotypes and two water regimes (FC and 1/3 available water; 1/3 AW) were arranged in factorial ...

  17. Hall probe magnetometer for SSC magnet cables

    International Nuclear Information System (INIS)

    Cross, R.W.; Goldfarb, R.B.

    1991-01-01

    The authors of this paper constructed a Hall probe magnetometer to measure the magnetization hysteresis loops of Superconducting Super Collider magnet cables. The instrument uses two Hall-effect field sensors to measure the applied field H and the magnetic induction B. Magnetization M is calculated from the difference of the two quantities. The Hall probes are centered coaxially in the bore of a superconducting solenoid with the B probe against the sample's broad surface. An alternative probe arrangement, in which M is measured directly, aligns the sample probe parallel to the field. The authors measured M as a function of H and field cycle rate both with and without a dc transport current. Flux creep as a function of current was measured from the dependence of ac loss on the cycling rate and from the decay of magnetization with time. Transport currents up to 20% of the critical current have minimal effect on magnetization and flux creep

  18. Probing topology and dynamics of the second transmembrane domain (M2δ) of the acetyl choline receptor using magnetically aligned lipid bilayers (bicelles) and EPR spectroscopy.

    Science.gov (United States)

    Sahu, Indra D; Mayo, Daniel J; Subbaraman, Nidhi; Inbaraj, Johnson J; McCarrick, Robert M; Lorigan, Gary A

    2017-08-01

    Characterizing membrane protein structure and dynamics in the lipid bilayer membrane is very important but experimentally challenging. EPR spectroscopy offers a unique set of techniques to investigate a membrane protein structure, dynamics, topology, and distance constraints in lipid bilayers. Previously our lab demonstrated the use of magnetically aligned phospholipid bilayers (bicelles) for probing topology and dynamics of the membrane peptide M2δ of the acetyl choline receptor (AchR) as a proof of concept. In this study, magnetically aligned phospholipid bilayers and rigid spin labels were further utilized to provide improved dynamic information and topology of M2δ peptide. Seven TOAC-labeled AchR M2δ peptides were synthesized to demonstrate the utility of a multi-labeling amino acid substitution alignment strategy. Our data revealed the helical tilts to be 11°, 17°, 9°, 17°, 16°, 11°, 9°±4° for residues I7TOAC, Q13TOAC, A14TOAC, V15TOAC, C16TOAC, L17TOAC, and L18TOAC, respectively. The average helical tilt of the M2δ peptide was determined to be ∼13°. This study also revealed that the TOAC labels were attached to the M2δ peptide with different dynamics suggesting that the sites towards the C-terminal end are more rigid when compared to the sites towards the N-terminus. The dynamics of the TOAC labeled sites were more resolved in the aligned samples when compared to the randomly disordered samples. This study highlights the use of magnetically aligned lipid bilayer EPR technique to determine a more accurate helical tilt and more resolved local dynamics of AchR M2δ peptide. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. One-time versus repeated abutment connection for platform-switched implant: A systematic review and meta-analysis.

    Science.gov (United States)

    Wang, Qing-Qing; Dai, Ruoxi; Cao, Chris Ying; Fang, Hui; Han, Min; Li, Quan-Li

    2017-01-01

    This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria. Outcome measures included peri-implant bone changes (mm), peri-implant soft tissue changes (mm), probing depth (mm) and postsurgical complications. Six studies were pooled for meta-analysis on bone tissue, three for soft tissue, two for probing depth and four for postsurgical complications. A total of 197 implants were placed in one-time abutment group, whereas 214 implants were included in repeated abutment group. The implant systems included Global implants, Ankylos, JDEvolution (JdentalCare), Straumann Bone level and Conelog-Screwline. One-time abutment group showed significantly better outcomes than repeated abutment group, as measured in the standardised differences in mean values (fixed- and random-effect model): vertical bone change (0.41, 3.23) in 6 months, (1.51, 14.81) in 12 months and (2.47, 2.47) in 3 years and soft tissue change (0.21, 0.23). No significant difference was observed in terms of probing depth and complications. Our meta-analysis revealed that implant restoration protocol using one-time abutment is superior to repeated abutment for platform switched implant because of less bone resorption and soft tissue shifts in former. However, future randomised clinical trials should be conducted to further confirm these findings because of the small samples and the limited quality of the original research.

  20. Hot HB Stars in Globular Clusters - Physical Parameters and Consequences for Theory. VI. The Second Parameter Pair M3 and M13

    Science.gov (United States)

    Moehler, S.; Landsman, W. B.; Sweigart, A. V.; Grundahl, F.

    2002-01-01

    We present the results of spectroscopic analyses of hot horizontal branch (HB) stars in M13 and M3, which form a famous second parameter pair. From the spectra we derived - for the first time in M13 - atmospheric parameters (effective temperature and surface gravity) as well as abundances of helium, magnesium, and iron. Consistent with analyses of hot HB stars in other globular clusters we find evidence for helium depletion and iron enrichment in stars hotter than about 12,000 K in both M3 and M13. Accounting for the iron enrichment substantially improves the agreement with canonical evolutionary models, although the derived gravities and masses are still somewhat too low. This remaining discrepancy may be an indication that scaled-solar metal-rich model atmospheres do not adequately represent the highly non-solar abundance ratios found in blue HB stars with radiative levitation. We discuss the effects of an enhancement in the envelope helium abundance on the atmospheric parameters of the blue HB stars, as might be caused by deep mixing on the red giant branch or primordial pollution from an earlier generation of intermediate mass asymptotic giant branch stars.

  1. Tidal radii of the globular clusters M 5, M 12, M 13, M 15, M 53, NGC 5053 and NGC 5466 from automated star counts.

    Science.gov (United States)

    Lehmann, I.; Scholz, R.-D.

    1997-04-01

    We present new tidal radii for seven Galactic globular clusters using the method of automated star counts on Schmidt plates of the Tautenburg, Palomar and UK telescopes. The plates were fully scanned with the APM system in Cambridge (UK). Special account was given to a reliable background subtraction and the correction of crowding effects in the central cluster region. For the latter we used a new kind of crowding correction based on a statistical approach to the distribution of stellar images and the luminosity function of the cluster stars in the uncrowded area. The star counts were correlated with surface brightness profiles of different authors to obtain complete projected density profiles of the globular clusters. Fitting an empirical density law (King 1962) we derived the following structural parameters: tidal radius r_t_, core radius r_c_ and concentration parameter c. In the cases of NGC 5466, M 5, M 12, M 13 and M 15 we found an indication for a tidal tail around these objects (cf. Grillmair et al. 1995).

  2. Differential regulation of proopiomelanocortin (POMC mRNA expression in hypothalamus and anterior pituitary following repeated cyanamide with ethanol administration

    Directory of Open Access Journals (Sweden)

    Kinoshita Hiroshi

    2005-01-01

    Full Text Available Background/Aim. We have investigated proopiomelanocortin (POMC mRNA expression in the arcuate nucleus of the hypothalamus (ARC and the anterior lobe of the pituitary (AL following repeated cyanamide-ethanol reaction (CER. Methods. Adult male Sprague -Dawley rats (250 −290 gr were housed in a temperature and humidity controlled environment with free access to food and water. Four experimental groups were used as follows: saline (as control, cyanamide alone, ethanol alone and ethanol with cyanamide. The animals received daily intraperitoneal injections (i.p. of cyanamide (10mg/kg, 60 min before ethanol dosing with or without ethanol (1g/kg for 5 consecutive days, and were sacrificed 60 min after the last dosing of ethanol. The results were presented as the mean ± SEM for each group. All groups within each data set were compared by one-way ANOVA followed by Fisher PLSD test for multiple comparisons. A value of p<0.05 was considered significant. Results. The POMC mRNA levels in ARC were significantly decreased with cyanamide compared to the control and ethanol alone (p<0.05 and p<0.05 respectively, but increased in AL following repeated CER. Conclusion. We speculate that this differential regulation of POMC mRNA expression may be partially involved in the preventive effects on alcohol intake in response to CER.

  3. A rhodamine-labeled citalopram analogue as a high-affinity fluorescent probe for the serotonin transporter

    DEFF Research Database (Denmark)

    Zhang, Peng; Jørgensen, Trine Nygaard; Løland, Claus Juul

    2013-01-01

    A novel fluorescent ligand was synthesized as a high-affinity, high specificity probe for visualizing the serotonin transporter (SERT). The rhodamine fluorophore was extended from an aniline substitution on the 5-position of the dihydroisobenzofuran ring of citalopram (2, 1-(3-(dimethylamino......)propyl)-1-(4-fluorophenyl)-1,3-dihydroisobenzofuran-5-carbonitrile), using an ethylamino linker. The resulting rhodamine-labeled ligand 8 inhibited [3H]5-HT uptake in COS-7 cells (Ki = 225 nM) with similar potency to the tropane-based JHC 1-064 (1), but with higher specificity towards the SERT relative...

  4. Genomic organization and developmental fate of adjacent repeated sequences in a foldback DNA clone of Tetrahymena thermophila

    International Nuclear Information System (INIS)

    Tschunko, A.H.; Loechel, R.H.; McLaren, N.C.; Allen, S.L.

    1987-01-01

    DNA sequence elimination and rearrangement occurs during the development of somatic cell lineages of eukaryotes and was first discovered over a century ago. However, the significance and mechanism of chromatin elimination are not understood. DNA elimination also occurs during the development of the somatic macronucleus from the germinal micronucleus in unicellular ciliated protozoa such as Tetrahymena thermophila. In this study foldback DNA from the micronucleus was used as a probe to isolate ten clones. All of those tested (4/4) contained sequences that were repetitive in the micronucleus and rearranged in the macronucleus. Inverted repeated sequences were present in one clone. This clone, pTtFBl, was subjected to a detailed analysis of its developmental fate. Subregions were subcloned and used as probes against Southern blots of micronuclear and macronuclear DNA. DNA was labeled with [ 33 P]-labeled dATP. The authors found that all subregions defined repeated sequence families in the micronuclear genome. A minimum of four different families was defined, two of which are retained in the macronucleus and two of which are completely eliminated. The inverted repeat family is retained with little rearrangement. Two of the families, defined by subregions that do not contain parts of the inverted repeat are totally eliminated during macronuclear development-and contain open reading frames. The significance of retained inverted repeats to the process of elimination is discussed

  5. Isolation and characterization of repeat elements of the oak genome and their application in population analysis

    International Nuclear Information System (INIS)

    Fluch, S.; Burg, K.

    1998-01-01

    Four minisatellite sequence elements have been identified and isolated from the genome of the oak species Quercus petraea and Quercus robur. Minisatellites 1 and 2 are putative members of repeat families, while minisatellites 3 and 4 show repeat length variation among individuals of test populations. A 590 base pair (bp) long element has also been identified which reveals individual-specific autoradiographic patterns when used as probe in Southern hybridisations of genomic oak DNA. (author)

  6. Early-type galaxies: mass-size relation at z ˜ 1.3 for different environments

    Science.gov (United States)

    Raichoor, A.; Mei, S.; Stanford, S. A.; Holden, B. P.; Nakata, F.; Rosati, P.; Shankar, F.; Tanaka, M.; Ford, H.; Huertas-Company, M.; Illingworth, G.; Kodama, T.; Postman, M.; Rettura, A.; Blakeslee, J. P.; Demarco, R.; Jee, M. J.; White, R. L.

    2011-12-01

    We combine multi-wavelength data of the Lynx superstructure and GOODS/CDF-S to build a sample of 75 visually selected early-type galaxies (ETGs), spanning different environments (cluster/group/field) at z ˜ 1.3. By estimating their mass, age (SED fitting, with a careful attention to the stellar population model used) and size, we are able to probe the dependence on the environment of the mass-size relation. We find that, for ETGs with 10^{10} < M / M_⊙ < 10^{11.5}, (1) the mass-size relation in the field did not evolve overall from z ˜ 1.3 to present; (2) the mass-size relation in cluster/group environments at z ˜ 1.3 lies at smaller sizes than the local mass-size relation (R_{e,z ˜ 1.3}/R_{e,z = 0} ˜ 0.6-0.8).

  7. Energetic M1 transitions as a probe of nuclear collectivity at high temperatures

    International Nuclear Information System (INIS)

    Baktash, C.

    1987-01-01

    At ORNL, we have recently utilized the Spin Spectrometer setup to investigate the differential effects of increasing spin and excitation energy on nuclear shape and collectivity in 158 Yb. Along the yrast line of this and other N = 88 nuclei, weakly prolate shapes gradually give way to triaxial, and then finally to non-collective oblate shapes as the spin approaches 40 h-bar. However, above the yrast line, large deformation and collectivity once again sets in. This is evidenced by the emergence of a broad quadrupole structure (E/sub γ/ ≅ 1.2 MeV) in the continuum gamma-ray spectra that grows with increasing temperature. The short (sub ps) lifetimes of these transitions attest to the collective nature of these structures. The emergence and growth of the quadrupole structure at high excitation energies is closely correlated with the appearance of energetic (E/sub γ/ ≅ 2.5 MeV), fast M1 transitions which form another broad structure in the continuum spectra. From the centroid of the M1 bump, a quadrupole deformation parameter of 0.35 is inferred. Because of this sensitivity, these energetic M1 transitions provide a unique probe of nuclear shape in the excitation energy range of ≅ 3 to 10 MeV. 6 refs., 2 figs

  8. Comparative Evaluation of Pain Scores during Periodontal Probing with or without Anesthetic Gels.

    Science.gov (United States)

    Mishra, Ashank; Priyanka, Mandapathi; Pradeep, Koppolu; Reddy Pathakota, Krishnajaneya

    2016-01-01

    Context. The initial periodontal examination which includes full-mouth periodontal probing is one of the discomforting procedures for a patient. Aim. To evaluate the efficacy of two local anesthetic gels in the reduction of pain during periodontal probing using Florida probe in CGP patients in comparison with manual probing. Materials and Methods. Ninety systemically healthy patients with moderate to severe CGP patients were recruited. In each patient, the quadrants were randomly assigned to manual probing with UNC-15 probe, probing with Florida probe, and Florida probing with lidocaine 10% gel and with benzocaine 20% gel. In the quadrants undergoing probing with anesthetic gels, the sites were isolated and the gel was injected using syringe and a blunt-end cannula. Pain was measured using 10 mm horizontal VAS. Statistical Analysis. The analysis was carried out using SPSS version 18. The comparison of mean VAS scores was done using repeated measures ANOVA with post hoc Bonferroni test. Results. Mean VAS for manual probing was significantly more than Florida probing. Further, the mean VAS score for Florida probing was higher than the two gels. Conclusion. It is suggested that the gels might be useful in reducing pain experienced during full-mouth periodontal probing in patients with CGP.

  9. Radioactive and enzymatic cloned cDNA probes for bovine enteric coronavirus detection by molecular hybridization

    Energy Technology Data Exchange (ETDEWEB)

    Collomb, J; Finance, C; Alabouch, S [Lab. de Microbiologie Moleculaire, Faculte des Sciences Pharmaceutiques et Biologiques, Univ. de Nancy I, Nancy (France); Laporte, J [Station de Virologie et d' Immunologie Moleculaires, INRA, Jouy-en-Josas (France)

    1992-01-01

    Genomic RNA of F15 strain bovine enteric coronavirus (BECV) was cloned in E. coli. Three clones (174, 160, PG 78), selected in the cDNA library, including a large portion of the nucleocapsid (N), matrix (M) and peplomeric (S) protein genes , were used as probes for a slot blot hybridization assay. Two probe labelling techniques were compared, radiolabeled with [sup 32]P and enzymatic labeled through covalent linkage to peroxidase for chemiluminescence detection. The radioactive probe 174 detected as little as 1-3 pg of viral RNA, while the less sensitive enzymatic probe could not reveal more than 100 pg of RNA. No significant detection amplification was achieved when a mixture of the three probes was used. Probe 174 allowed specific identification for BECV. No hybridization was noticed either with rotaviruses or even with other antigenically unrelated members of the family Coronaviridae such as transmissible gastroenteritis virus. The test proved valid for detection of BECV in the supernatant of infected HRT-18 cells: genomic RNA could be detected after direct spotting of samples, but prior nucleic acid extraction after proteinase K treatment improved virus detection. BECV diagnosis in fecal samples using enzymatic probe was compared with conventional diagnostic methods. (authors).

  10. Radical probing of spliceosome assembly.

    Science.gov (United States)

    Grewal, Charnpal S; Kent, Oliver A; MacMillan, Andrew M

    2017-08-01

    Here we describe the synthesis and use of a directed hydroxyl radical probe, tethered to a pre-mRNA substrate, to map the structure of this substrate during the spliceosome assembly process. These studies indicate an early organization and proximation of conserved pre-mRNA sequences during spliceosome assembly. This methodology may be adapted to the synthesis of a wide variety of modified RNAs for use as probes of RNA structure and RNA-protein interaction. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Characterization of the main error sources of chromatic confocal probes for dimensional measurement

    International Nuclear Information System (INIS)

    Nouira, H; El-Hayek, N; Yuan, X; Anwer, N

    2014-01-01

    Chromatic confocal probes are increasingly used in high-precision dimensional metrology applications such as roughness, form, thickness and surface profile measurements; however, their measurement behaviour is not well understood and must be characterized at a nanometre level. This paper provides a calibration bench for the characterization of two chromatic confocal probes of 20 and 350 µm travel ranges. The metrology loop that includes the chromatic confocal probe is stable and enables measurement repeatability at the nanometer level. With the proposed system, the major error sources, such as the relative axial and radial motions of the probe with respect to the sample, the material, colour and roughness of the measured sample, the relative deviation/tilt of the probe and the scanning speed are identified. Experimental test results show that the chromatic confocal probes are sensitive to these errors and that their measurement behaviour is highly dependent on them. (paper)

  12. Assessment of the National Research Universal Reactor Proposed New Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, John A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Antonio, Ernest J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Flaherty, Julia E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-02-29

    This document reports on a series of tests conducted to assess the proposed air sampling location for the National Research Universal reactor (NRU) complex exhaust stack, located in Chalk River, Ontario, Canada, with respect to the applicable criteria regarding the placement of an air sampling probe. Due to the age of the equipment in the existing monitoring system, and the increasing difficulty in acquiring replacement parts to maintain this equipment, a more up-to-date system is planned to replace the current effluent monitoring system, and a new monitoring location has been proposed. The new sampling probe should be located within the exhaust stack according to the criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The internal Pacific Northwest National Laboratory (PNNL) project for this task was 65167, Atomic Energy Canada Ltd. Chalk River Effluent Duct Flow Qualification. The testing described in this document was guided by the Test Plan: Testing of the NRU Stack Air Sampling Position (TP-STMON-032).

  13. Characterization of local hydrophobicity on sapphire (0001) surfaces in aqueous environment by colloidal probe atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wada, Tomoya; Yamazaki, Kenji; Isono, Toshinari; Ogino, Toshio, E-mail: ogino-toshio-rx@ynu.ac.jp

    2017-02-28

    Highlights: • Local hydrophobicity of phase-separated sapphire (0001) surfaces was investigated. • These surfaces are featured by coexistence of hydrophilic and hydrophobic domains. • Each domain was characterized by colloidal probe atomic force microscopy in water. • Both domains can be distinguished by adhesive forces of the probe to the surfaces. • Characterization in aqueous environment is important in bio-applications of sapphire. - Abstract: Sapphire (0001) surfaces exhibit a phase-separation into hydrophobic and hydrophilic domains upon high-temperature annealing, which were previously distinguished by the thickness of adsorbed water layers in air using atomic force microscopy (AFM). To characterize their local surface hydrophobicity in aqueous environment, we used AFM equipped with a colloidal probe and measured the local adhesive force between each sapphire domain and a hydrophilic SiO{sub 2} probe surface, or a hydrophobic polystyrene one. Two data acquisition modes for statistical analyses were used: one is force measurements at different positions of the surface and the other repeated measurement at a fixed position. We found that adhesive force measurements using the polystyrene probe allow us to distinctly separate the hydrophilic and hydrophobic domains. The dispersion in the force measurement data at different positions of the surface is larger than that in the repeated measurements at a fixed position. It indicates that the adhesive force measurement is repeatable although their data dispersion for the measurement positions is relatively large. From these results, we can conclude that the hydrophilic and hydrophobic domains on the sapphire (0001) surfaces are distinguished by a difference in their hydration degrees.

  14. Developmental expression of proprotein convertase 1/3 in the rat

    DEFF Research Database (Denmark)

    Lee, Y C; Damholt, A B; Billestrup, N

    1999-01-01

    demonstrated that it was relatively abundant in whole brain, lung and spleen, but not detectable in kidney, testis and heart. Using probes consisting of either the coding region or the 3' end sequences, the mRNA transcripts identified were 5.0, 3.0 and 8.5 kb. The 8.5 kb transcript detected has not been....../3 expression were detected in fetal lung, whereas low and constant expression was detected in fetal liver. Double immuno-staining showed that PC1/3 was co-localised with insulin throughout development, and at mid-gestation, PC1/3 immunoreactivity could also be detected within glucagon-producing cells...

  15. Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPECT in Coronary Artery Disease

    International Nuclear Information System (INIS)

    Kong, Eun Jung; Cho, Ihn Ho; Chun, Kyung Ah; Won, Kyu Chang; Lee, Hyung Woo; Park, Jeong Sun; Shin, Dong Gu; Kim, Young Jo; Shim, Bong Seop

    2008-01-01

    N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Seventeen patients (male 13 : 63±11 years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/ 89% vs MPS: 65%/ 82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversible by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability

  16. Sixty-five radiation hybrids for the short arm of human chromosome 6: their value as a mapping panel and as a source for rapid isolation of new probes using repeat element-mediated PCR

    International Nuclear Information System (INIS)

    Zoghbi, H.Y.; McCall, A.E.; LeBorgne-Demarquoy, F.

    1991-01-01

    We have used an irradiation and fusion procedure to generate somatic cell hybrids that retain fragments of the short arm of human chromosome 6 (6p). To identify hybrids retaining human material, we performed repeat element-mediated PCR on crude lysates of cells from individual clones. Sixty-five hybrids were shown to contain human material and fifty of those contained one or more 6p-specific probes. Detailed characterization of these hybrids identified a subset that divides 6p into ten mapping intervals. Using repeat element-mediated PCR, we were able to isolate and map 61 new DNA fragments from specific regions of 6p. Fifteen of these fragments were used to screen for restriction fragment length polymorphisms (RFLPs), and nine identified RFLPs with one or more enzymes. The radiation hybrids described in this study provide a valuable resource for high-resolution mapping of 6p and for the rapid isolation of region-specific markers

  17. REPETIBILIDADE DE CARACTERES DO CACHO DE AÇAIZEIRO NAS CONDIÇÕES DE BELÉM-PA REPEATIBILITY OF CHARACTERS OF THE RACEME OF AÇAI PALM AT BELÉM-PA

    Directory of Open Access Journals (Sweden)

    MARIA DO SOCORRO PADILHA DE OLIVEIRA

    2001-12-01

    Full Text Available Estimou-se o coeficiente de repetibilidade em caracteres do cacho de açaizeiro (Euterpe oleracea Mart. nas condições de Belém-PA, com o intuito de determinar a capacidade de eles expressarem a variabilidade genética dessa fruteira. Para tanto, foram colhidos quatro cachos por planta, todos apresentando completa maturação, em 30 genótipos pertencentes à Coleção de Germoplasma de Açaí da Embrapa Amazônia Oriental, onde foram mensurados seis caracteres: peso total do cacho (PTC, peso de frutos por cacho (PFC, número de frutos por cacho (NFC, número de ráquilas por cacho (NRC, peso médio do fruto (PMF e rendimento de frutos por cacho (RFC. A análise da repetibilidade, do número de medições necessárias e do coeficiente de determinação para cada caráter foi obtida através do método da análise de variância, utilizando o modelo com dois fatores de variação. Verificou-se que todos os caracteres apresentaram diferenças significativas entre genótipos, com o número de frutos, número de ráquilas e peso médio do fruto, evidenciando diferenças ao nível de 1% de probabilidade. Porém, o maior coeficiente de repetibilidade foi registrado para peso médio do fruto, enquanto os demais caracteres apresentaram valores inexpressivos. Essa variável teve, também, o maior coeficiente de determinação; entretanto, o número de repetições desejável para esse caráter deve ser quase o triplo do usado nesse estudo. Pelo fato de o coeficiente de repetibilidade expressar o valor máximo de herdabilidade, conclui-se que o PMF pode ser usado como parâmetro de seleção em métodos de melhoramento menos rigorosos.Was considered the repeatibility coefficient in characters of raceme in açai palm (Euterpe oleracea Mart. at Belém-PA with the intention of determining their capacity to express the genetic variability of that fruit bowl. For that were picked four racemes by plant, all presenting complete maturation, in 30 genotypes

  18. Magnitude of exercise capacity and quality of life improvement following repeat pulmonary rehabilitation in patients with COPD

    Directory of Open Access Journals (Sweden)

    Sandoz JS

    2017-04-01

    Full Text Available Jacqueline S Sandoz,1,2 Mary M Roberts,1,3,4 Jin-Gun Cho,1,3–5 John R Wheatley1,3–5 1Respiratory Ambulatory Care Service, Western Sydney Local Health District, NSW, Australia; 2Canadian Alternatives in Non-invasive Ventilation (CANVent Program, Ottawa Hospital Rehabilitation Centre, Division of Respiratory Medicine, Ottawa Hospital, Ontario, Canada; 3Department of Respiratory and Sleep Medicine, Westmead Hospital, 4Ludwig Engel Centre for Respiratory Research, Westmead Institute for Medical Research, 5Sydney Medical School, University of Sydney, Westmead, NSW, Australia Background: Maintenance and repeated pulmonary rehabilitation programs (PRPs for patients with COPD have attempted to prolong PRP benefits beyond 12–24 months. However, there is limited evidence as to the magnitude of benefit or the ideal interval between repeating the program under “real-world” conditions in which patients are referred based on clinical necessity. Therefore, we reviewed the effects of repeating PRP in a physician-referred cohort of patients with COPD. Methods: A total of 141 individuals with COPD completed PRP twice and 35 completed PRP three times over a 12-year period. We used linear mixed-effects models to quantify the magnitude and change in 6-minute walk distance (6MWD, St George’s Respiratory Questionnaire (SGRQ, and Hospital Anxiety and Depression Scale (HADS for each PRP. One-way analysis of variance with Tukey’s post hoc analysis compared the effects of different time intervals on 6MWD, SGRQ, and HADS between PRPs. Results: Despite 39 mL/year average decrease in forced expiratory volume in 1 second, overall 6MWD improved following each PRP (PRP1=58 m, P<0.0001; PRP2=42 m, P<0.0001; PRP3=32 m, P<0.003. Mean SGRQ decreased after PRP1 (-7.0 units; P<0.001 and PRP2 (-4.9 units;P<0.0001 but not after PRP3 (-3.2 units; P=0.10. HADS decreased after PRP1 (-1.9 units; P<0.0001 and PRP2 (-1.7 units; P=0.0001 but not after PRP3 (-0.4 units

  19. High-performance 1.3m laser diode by LP-MOVPE

    Science.gov (United States)

    Li, TongNing; Ji, Jin-yan; Yan, Xin-min; Liu, Tao; Ning, Zhou; Liu, Jiang; Liu, Zi-li; Huang, Ge-fan

    1996-09-01

    The progress in 1.3 micrometers wavelength InGaAsP/InP lasers for optic fiber communication and subscriber loop applications is reviewed. By using LP-MOVPE/LPE epitaxy techniques, the performance of commercial optical devices is considerably improved. The bandwidth of the 1.3 micrometers uncooled MQW-LD module could be high to 1.6GHz, threshold current Ith = 20mW while uniformity, reproducible, high yield are achieved. Further by growing active layer with compressive strained structure the lowest threshold current Ith equals 3.8mA was achieved with high reflection coating and the temperature performance of the SL-MQW-LD has been greatly improved, the change of slop efficiency at 25 degrees C and 85 degrees C is less than 1 dB. Using the holographic technique a high power 1.31 micrometers InGaAsP/InP multiquantum well distributed feedback laser has also been developed. The fiber output power of butterfly packaged module with optic isolator Pf > 10mW, threshold current Ith 22 percent and side mode suppression ratio SMSR > 40dB. The composite triple beat CTB test frequencies equals 55.25 to approximately 289.25MHz with 40 NCTA channels, the carrier to noise ration CNR > 50 dB and the relative intensity noise RIN < -160dB/Hz.

  20. The biological characterization of 99mTc-BnAO-NI as a SPECT probe for imaging hypoxia in a sarcoma-bearing mouse model

    International Nuclear Information System (INIS)

    Hsia, Chien-Chung; Huang, Fu-Lei; Hung, Guang-Uei; Shen, Lie-Hang; Chen, Chuan-Lin; Wang, Hsin-Ell

    2011-01-01

    Objectives: Tumor growth beyond the region where vascular oxygen can reach creates a hypoxic domain. In this study, BnAO, a ligand that had been labeled with 99m Tc-pertechnetate for hypoxia imaging, was conjugated with 2-nitroimidazole to give 3,3,10,10-tetramethyl-1-(2-nitro-1H-imidazo-1-y1)-4,9-diazadodecane-2,11- dionedioxime (BnAO-NI) as a potential ligand for hypoxia detection. Pentoxifylline is a peripheral vasodilator and has been used as a radiosensitizer in tumor radiotherapy. 99m Tc-BnAO-NI/SPECT was applied to noninvasively assess the pharmacological effect of pentoxifylline in reducing tumor hypoxia in vivo. Methods: BnAO-NI was synthesized and formulated with methylene diphosphonate (MDP), stannous chloride and carbonate buffer to afford kits. After mixing with 99m Tc-pertechnetate, 99m Tc-BnAO-NI injection can be readily prepared. The partition coefficient, radiochemical purity and in vitro stability were determined. Cellular uptake of radiotracers in KHT cells under hypoxia was conducted in a CO 2 incubator at 37 o C under hypoxia or normoxia. A biodistribution study after intravenous injection of 99m Tc-BnAO-NI in KHT sarcoma-implanted C3H mice was performed. The effect of pentoxifylline (100 mg/kg) on reducing tumor hypoxia was also studied. Results: The radiochemical purity (RCP) of the 99m Tc-BnAO-NI preparation was greater than 96% and stable at ambient temperature for 24 h (RCP>90%). The accumulation of 99m Tc-BnAO-NI and 99m Tc-BnAO in KHT cells under hypoxia were 3.57 and 4.13-fold higher than those under normoxic environment, indicating unambiguous oxygen-dependent uptakes of these two probes. The distribution of 99m Tc-BnAO-NI in KHT sarcoma-bearing mice revealed rapid clearance from the blood circulation. The tumor uptake peaked at 2 h post-injection (0.32±0.05%ID/g) with tumor-to-blood and tumor-to-muscle ratios of 10.32 and 3.96, respectively. The effect of pentoxifylline on the tumor blood perfusion was obvious. The tumor

  1. VizieR Online Data Catalog: Early observations of M13 variables (Osborn,+, 2016)

    Science.gov (United States)

    Osborn, W.; Barnard, E. E.

    2018-05-01

    In 1900 E.E. Barnard published 37 visual observations of Variable 2 (V2) in the globular cluster M13 made in 1899 and 1900. A review of Barnard's notebooks revealed he made many additional brightness estimates up to 1911, and he had also recorded the variations of V1 starting in 1904. These data provide the earliest-epoch light curves for these stars and thus are useful for studying their period changes. This paper presents Barnard's observations of the M13 variables along with their derived heliocentric Julian dates and approximate V magnitudes. These include 231 unpublished observations of V2 and 94 of V1. How these data will be of value for determining period changes by these stars is described. (5 data files).

  2. An interchangeable scanning Hall probe/scanning SQUID microscope

    International Nuclear Information System (INIS)

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin; Chen, Tse-Jun; Wang, M. J.; Ling, D. C.; Chi, C. C.; Chen, Jeng-Chung

    2014-01-01

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10 −7 T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La 2/3 Ca 1/3 MnO 3 thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K

  3. Visualization of mcr mRNA in a methanogen by fluorescence in situ hybridization with an oligonucleotide probe and two-pass tyramide signal amplification (two-pass TSA-FISH).

    Science.gov (United States)

    Kubota, Kengo; Ohashi, Akiyoshi; Imachi, Hiroyuki; Harada, Hideki

    2006-09-01

    Two-pass tyramide signal amplification-fluorescence in situ hybridization (two-pass TSA-FISH) with a horseradish peroxidase (HRP)-labeled oligonucleotide probe was applied to detect prokaryotic mRNA. In this study, mRNA of a key enzyme for methanogenesis, methyl coenzyme M reductase (mcr), in Methanococcus vannielii was targeted. Applicability of mRNA-targeted probes to in situ hybridization was verified by Clone-FISH. It was observed that sensitivity of two-pass TSA-FISH was significantly higher than that of TSA-FISH, which was further increased by the addition of dextran sulphate in TSA working solution. Signals from two-pass TSA-FISH were more reliable compared to the weak, spotty signals yielded by TSA-FISH.

  4. Nanobits: customizable scanning probe tips

    DEFF Research Database (Denmark)

    Kumar, Rajendra; Shaik, Hassan Uddin; Sardan Sukas, Özlem

    2009-01-01

    We present here a proof-of-principle study of scanning probe tips defined by planar nanolithography and integrated with AFM probes using nanomanipulation. The so-called 'nanobits' are 2-4 mu m long and 120-150 nm thin flakes of Si3N4 or SiO2, fabricated by electron beam lithography and standard s...

  5. Repeat Stereotactic Radiosurgery for Acoustic Neuromas

    International Nuclear Information System (INIS)

    Kano, Hideyuki; Kondziolka, Douglas; Niranjan, Ajay M.Ch.; Flannery, Thomas J.; Flickinger, John C.; Lunsford, L. Dade

    2010-01-01

    Purpose: To evaluate the outcome of repeat stereotactic radiosurgery (SRS) for acoustic neuromas, we assessed tumor control, clinical outcomes, and the risk of adverse radiation effects in patients whose tumors progressed after initial management. Methods and Materials: During a 21-year experience at our center, 1,352 patients underwent SRS as management for their acoustic neuromas. We retrospectively identified 6 patients who underwent SRS twice for the same tumor. The median patient age was 47 years (range, 35-71 years). All patients had imaging evidence of tumor progression despite initial SRS. One patient also had incomplete surgical resection after initial SRS. All patients were deaf at the time of the second SRS. The median radiosurgery target volume at the time of the initial SRS was 0.5 cc and was 2.1 cc at the time of the second SRS. The median margin dose at the time of the initial SRS was 13 Gy and was 11 Gy at the time of the second SRS. The median interval between initial SRS and repeat SRS was 63 months (range, 25-169 months). Results: At a median follow-up of 29 months after the second SRS (range, 13-71 months), tumor control or regression was achieved in all 6 patients. No patient developed symptomatic adverse radiation effects or new neurological symptoms after the second SRS. Conclusions: With this limited experience, we found that repeat SRS for a persistently enlarging acoustic neuroma can be performed safely and effectively.

  6. Development of a contact probe incorporating a Bragg grating strain sensor for nano coordinate measuring machines

    International Nuclear Information System (INIS)

    Ji, H; Hsu, H-Y; Kong, L X; Wedding, A B

    2009-01-01

    This paper presents a novel optical fibre based micro contact probe system with high sensitivity and repeatability. In this optical fibre probe with a fused spherical tip, a fibre Bragg grating has been utilized as a strain sensor in the probe stem. When the probe tip contacts the surface of the part, a strain will be induced along the probe stem and will produce a Bragg wavelength shift. The contact signal can be issued once the wavelength shift signal is produced and demodulated. With the fibre grating sensor element integrated into the probe directly, the probe system shows a high sensitivity. In this work, the strain distributions along the probe stem with the probe under axial and lateral load are analysed. A simulation of the strain distribution was performed using the finite element package ANSYS 11. Performance tests using a piezoelectric transducer stage with a displacement resolution of 1.5 nm yielded a measurement resolution of 60 nm under axial loading

  7. Amino acid repeats avert mRNA folding through conservative substitutions and synonymous codons, regardless of codon bias

    Directory of Open Access Journals (Sweden)

    Sailen Barik

    2017-12-01

    Full Text Available A significant number of proteins in all living species contains amino acid repeats (AARs of various lengths and compositions, many of which play important roles in protein structure and function. Here, I have surveyed select homopolymeric single [(An] and double [(ABn] AARs in the human proteome. A close examination of their codon pattern and analysis of RNA structure propensity led to the following set of empirical rules: (1 One class of amino acid repeats (Class I uses a mixture of synonymous codons, some of which approximate the codon bias ratio in the overall human proteome; (2 The second class (Class II disregards the codon bias ratio, and appears to have originated by simple repetition of the same codon (or just a few codons; and finally, (3 In all AARs (including Class I, Class II, and the in-betweens, the codons are chosen in a manner that precludes the formation of RNA secondary structure. It appears that the AAR genes have evolved by orchestrating a balance between codon usage and mRNA secondary structure. The insights gained here should provide a better understanding of AAR evolution and may assist in designing synthetic genes.

  8. Amino acid repeats avert mRNA folding through conservative substitutions and synonymous codons, regardless of codon bias.

    Science.gov (United States)

    Barik, Sailen

    2017-12-01

    A significant number of proteins in all living species contains amino acid repeats (AARs) of various lengths and compositions, many of which play important roles in protein structure and function. Here, I have surveyed select homopolymeric single [(A)n] and double [(AB)n] AARs in the human proteome. A close examination of their codon pattern and analysis of RNA structure propensity led to the following set of empirical rules: (1) One class of amino acid repeats (Class I) uses a mixture of synonymous codons, some of which approximate the codon bias ratio in the overall human proteome; (2) The second class (Class II) disregards the codon bias ratio, and appears to have originated by simple repetition of the same codon (or just a few codons); and finally, (3) In all AARs (including Class I, Class II, and the in-betweens), the codons are chosen in a manner that precludes the formation of RNA secondary structure. It appears that the AAR genes have evolved by orchestrating a balance between codon usage and mRNA secondary structure. The insights gained here should provide a better understanding of AAR evolution and may assist in designing synthetic genes.

  9. Probe for the mutagenic activity of the carcinogen 4-aminobiphenyl: synthesis and characterization of an M13mp10 genome containing the major carcinogen-DNA adduct at a unique site

    International Nuclear Information System (INIS)

    Lasko, D.D.; Basu, A.K.; Kadlubar, F.F.; Evans, F.E.; Lay, J.O. Jr.; Essigmann, J.M.

    1987-01-01

    The duplex genome of Escherichia coli virus M13mp10 was modified at a unique site to contain N-(deoxyguanosin-8-yl)-4-aminobiphenyl (dG/sup 8-ABP/), the major carcinogen-DNA adduct of the human bladder carcinogen 4-aminobiphenyl. A tetradeoxynucleotide containing a single dG/sup 8-ABP/ residue was synthesized by reacting 5'-d(TpGpCpA)-3' with N-acetoxy-N-(trifluoroacetyl)-4-aminobiphenyl, followed by high-performance liquid chromatography purification of the principal reaction product 5'-d(TpG/sup 8-ABP/pCpA)-3' (yield 15-30%). Characterization by fast atom bombardment mass spectrometry confirmed the structure as an intact 4-aminobiphenyl-modified tetranucleotide, while 1 H nuclear magnetic resonance spectroscopy established the site of substitution and the existence of ring stacking between the carcinogen residue and DNA bases. Experiments in which the tetranucleotides were 5' end labeled with [ 32 P]phosphate revealed the following: 1)the adducted oligomer, when incubated in a 1000-fold molar excess in the presence of T4 DNA ligase and ATP, was found to be incorporated into the gapped DNA molecules with an efficiency of approximately 30%, as compared to the unadducted d(pTpGpCpA), which was incorporated with 60% ligation efficiency; 2)radioactivity from the 5' end of each tetranucleotide was physically mapped to a restriction fragment that contained the PstI site and represented 0.2% of the genome; 3) the presence of the lesion within the PstI recognition site inhibited the ability of PstI to cleave the genome at this site; 4)in genomes in which ligation occurred, T4 DNA ligase was capable of covalently joining both modified and unmodified tetranucleotides to the gapped structures on both the 5' and the 3' ends with at least 90% efficiency. On the basis of these and other data, the dG/sup 8-ABP/-modified genome was judged to be a useful probe for investigation of site-specific mutagenesis in E. coli

  10. Triple-probe method applied to the direct display of plasma parameters in a supersonic flowing continuum plasma

    International Nuclear Information System (INIS)

    Ogram, G.L.; Chang, J.; Hobson, R.M.

    1979-01-01

    The calibration of electrostatic triple-probe voltage and current response in a supersonic continuum plasma has been carried out using a low-pressure shock tube. The electron temperature T/sub e/ and charge number density N/sub e/ are compared to probe voltage and current response, respectively, for a useful range of plasma parameters (1 13 13 is the nondimensional probe voltage). The dependence of probe response on Debye ratio R/sub p//lambda/sub D/ and various flow parameters was investigated. The probe voltage response was found to depend significantly on the Debye ratio. Expressions for electron temperature determination by triple probe are presented

  11. Genotypic characterization of Rickettsiae by DNA probes generated from Rickettsia Prowazekii DNA

    International Nuclear Information System (INIS)

    Demkin, V.V.; Rydkina, E.B.; Likhoded, L.Ya.; Ignatovich, V.F.; Genig, V.A.; Balayeva, N.M.

    1994-01-01

    Southern blot analysis of HindIII-cleaved rickettsial DNA was used for genotypic characterization of the typhus group (TG) species (R. prowazekii, R. typhi, R. canada) and a few species were of the spotted fever group (SFG)rickettsiae (R. sibirica, R. conorii, R. akari). Four different DNA probes were employed. PBH11 and PBH13 probes were morphospecific HindIII fragment of R prowazekii DNA. MW218 probe contained the gene for 51 K antigen and MW264 probe contained the citrate synthase gene of R. prowazekii. All the probes hybridized with the tested TG and SFG rickettsial DNAs, forming from 1 to 5 bands, but they did not with R. tsutsudamushi or C. burnetii DNAs. All the probes demonstrated specific hybridization pattern with TG species and R. akari. PBH11. PBH13 and MW264 probes clearly distinguished R. sibirica and R. conorii from the other tested rickettsiae, but not from each other. However, these two species differed slightly with MW218 probe. Several strains of each species were analyzed in this way and except for strains of R. conorii identical intra-species pattern were obtained. These data lead us to consider the obtained hybridization patterns as criteria for genotypic identification. (author)

  12. Repeated mild closed head injury impairs short-term visuospatial memory and complex learning.

    Science.gov (United States)

    Hylin, Michael J; Orsi, Sara A; Rozas, Natalia S; Hill, Julia L; Zhao, Jing; Redell, John B; Moore, Anthony N; Dash, Pramod K

    2013-05-01

    Concussive force can cause neurocognitive and neurobehavioral dysfunction by inducing functional, electrophysiological, and/or ultrastructural changes within the brain. Although concussion-triggered symptoms typically subside within days to weeks in most people, in 15%-20% of the cases, symptomology can continue beyond this time point. Problems with memory, attention, processing speed, and cognitive flexibility (e.g., problem solving, conflict resolution) are some of the prominent post-concussive cognitive symptoms. Repeated concussions (with loss or altered consciousness), which are common to many contact sports, can exacerbate these symptoms. The pathophysiology of repeated concussions is not well understood, nor is an effective treatment available. In order to facilitate drug discovery to treat post-concussive symptoms (PCSs), there is a need to determine if animal models of repeated mild closed head injury (mCHI) can mimic the neurocognitive and histopathological consequences of repeated concussions. To this end, we employed a controlled cortical impact (CCI) device to deliver a mCHI directly to the skull of mice daily for 4 days, and examined the ensuing neurological and neurocognitive functions using beam balance, foot-fault, an abbreviated Morris water maze test, context discrimination, and active place avoidance tasks. Repeated mCHI exacerbated vestibulomotor, motor, short-term memory and conflict learning impairments as compared to a single mCHI. Learning and memory impairments were still observed in repeated mCHI mice when tested 3 months post-injury. Repeated mCHI also reduced cerebral perfusion, prolonged the inflammatory response, and in some animals, caused hippocampal neuronal loss. Our results show that repeated mCHI can reproduce some of the deficits seen after repeated concussions in humans and may be suitable for drug discovery studies and translational research.

  13. Miniature fibre optic probe for minimally invasive photoacoustic sensing

    Science.gov (United States)

    Mathews, Sunish J.; Zhang, Edward Z.; Desjardins, Adrien E.; Beard, Paul C.

    2016-03-01

    A miniature (175 μm) all-optical photoacoustic probe has been developed for minimally invasive sensing and imaging applications. The probe comprises a single optical fibre which delivers the excitation light and a broadband 50 MHz Fabry-Pérot (F-P) ultrasound sensor at the distal end for detecting the photoacoustic waves. A graded index lens proximal to the F-P sensor is used to reduce beam walk-off and thus increase sensitivity as well as confine the excitation beam in order to increase lateral spatial resolution. The probe was evaluated in non-scattering media and found to provide lateral and axial resolutions of < 100 μm and < 150 μm respectively for distances up to 1 cm from the tip of the probe. The ability of the probe to detect a blood vessel mimicking phantom at distances up to 7 mm from the tip was demonstrated in order to illustrate its potential suitability for needle guidance applications.

  14. Microarray of DNA probes on carboxylate functional beads surface

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The microarray of DNA probes with 5′-NH2 and 5′-Tex/3′-NH2 modified terminus on 10 m m carboxylate functional beads surface in the presence of 1-ethyl-3-(3-dimethylaminopropyl)- carbodiimide (EDC) is characterized in the present paper. It was found that the microarray capacity of DNA probes on the beads surface depends on the pH of the aqueous solution, the concentration of DNA probe and the total surface area of the beads. On optimal conditions, the minimum distance of 20 mer single-stranded DNA probe microarrayed on beads surface is about 14 nm, while that of 20 mer double-stranded DNA probes is about 27 nm. If the probe length increases from 20 mer to 35 mer, its microarray density decreases correspondingly. Mechanism study shows that the binding mode of DNA probes on the beads surface is nearly parallel to the beads surface.

  15. An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging.

    Science.gov (United States)

    Matrone, Giulia; Ramalli, Alessandro; Savoia, Alessandro Stuart; Quaglia, Fabio; Castellazzi, Gloria; Morbini, Patrizia; Piastra, Marco

    2017-09-24

    The possibility to perform an early and repeatable assessment of imaging performance is fundamental in the design and development process of new ultrasound (US) probes. Particularly, a more realistic analysis with application-specific imaging targets can be extremely valuable to assess the expected performance of US probes in their potential clinical field of application. The experimental protocol presented in this work was purposely designed to provide an application-specific assessment procedure for newly-developed US probe prototypes based on Capacitive Micromachined Ultrasonic Transducer (CMUT) technology in relation to brain imaging. The protocol combines the use of a bovine brain fixed in formalin as the imaging target, which ensures both realism and repeatability of the described procedures, and of neuronavigation techniques borrowed from neurosurgery. The US probe is in fact connected to a motion tracking system which acquires position data and enables the superposition of US images to reference Magnetic Resonance (MR) images of the brain. This provides a means for human experts to perform a visual qualitative assessment of the US probe imaging performance and to compare acquisitions made with different probes. Moreover, the protocol relies on the use of a complete and open research and development system for US image acquisition, i.e. the Ultrasound Advanced Open Platform (ULA-OP) scanner. The manuscript describes in detail the instruments and procedures involved in the protocol, in particular for the calibration, image acquisition and registration of US and MR images. The obtained results prove the effectiveness of the overall protocol presented, which is entirely open (within the limits of the instrumentation involved), repeatable, and covers the entire set of acquisition and processing activities for US images.

  16. Controlled attenuation parameter using the FibroScan® XL probe for quantification of hepatic steatosis for non-alcoholic fatty liver disease in an Asian population.

    Science.gov (United States)

    Chan, Wah-Kheong; Nik Mustapha, Nik Raihan; Wong, Grace Lai-Hung; Wong, Vincent Wai-Sun; Mahadeva, Sanjiv

    2017-02-01

    The FibroScan® XL probe reduces failure of liver stiffness measurement (LSM) and unreliable results in obese patients. The objective of this article is to evaluate the accuracy of controlled attenuation parameter (CAP) obtained using the XL probe for the estimation of hepatic steatosis in patients with non-alcoholic fatty liver disease (NAFLD). Adult NAFLD patients with a liver biopsy within six months were included and were examined with the FibroScan® M and XL probes. Histopathological findings were reported according to the Non-Alcoholic Steatohepatitis Clinical Research Network Scoring System. Participants who did not have fatty liver on ultrasonography were recruited as controls. A total of 57 NAFLD patients and 22 controls were included. The mean age of the NAFLD patients and controls was 50.1 ± 10.4 years and 20.2 ± 1.3 years, respectively ( p  = 0.000). The mean body mass index was 30.2 ± 5.0 kg per m 2 and 20.5 ± 2.4 kg per m 2 , respectively ( p  = 0.000). The distribution of steatosis grades were: S0, 29%; S1, 17%; S2, 35%; S3, 19%. The AUROC for estimation of steatosis grade ≥ S1, S2 and S3 was 0.94, 0.80 and 0.69, respectively, using the M probe, and 0.97, 0.81 and 0.67, respectively, using the XL probe. CAP obtained using the XL probe had similar accuracy as the M probe for the estimation of hepatic steatosis in NAFLD patients.

  17. The biological characterization of {sup 99m}Tc-BnAO-NI as a SPECT probe for imaging hypoxia in a sarcoma-bearing mouse model

    Energy Technology Data Exchange (ETDEWEB)

    Hsia, Chien-Chung [Institute of Biomedical imaging and Radiological Sciences, National Yang-Ming University, Taiwan (China); Institute of Nuclear Energy Research, Taiwan (China); Huang, Fu-Lei [Institute of Nuclear Energy Research, Taiwan (China); Hung, Guang-Uei [Department of Nuclear Medicine, Chang-Bing Show Chwan Hospital, Taiwan (China); Shen, Lie-Hang [Institute of Nuclear Energy Research, Taiwan (China); Chen, Chuan-Lin, E-mail: clchen2@ym.edu.t [Institute of Biomedical imaging and Radiological Sciences, National Yang-Ming University, Taiwan (China); Wang, Hsin-Ell, E-mail: hewang@ym.edu.t [Institute of Biomedical imaging and Radiological Sciences, National Yang-Ming University, Taiwan (China)

    2011-04-15

    Objectives: Tumor growth beyond the region where vascular oxygen can reach creates a hypoxic domain. In this study, BnAO, a ligand that had been labeled with {sup 99m}Tc-pertechnetate for hypoxia imaging, was conjugated with 2-nitroimidazole to give 3,3,10,10-tetramethyl-1-(2-nitro-1H-imidazo-1-y1)-4,9-diazadodecane-2,11- dionedioxime (BnAO-NI) as a potential ligand for hypoxia detection. Pentoxifylline is a peripheral vasodilator and has been used as a radiosensitizer in tumor radiotherapy. {sup 99m}Tc-BnAO-NI/SPECT was applied to noninvasively assess the pharmacological effect of pentoxifylline in reducing tumor hypoxia in vivo. Methods: BnAO-NI was synthesized and formulated with methylene diphosphonate (MDP), stannous chloride and carbonate buffer to afford kits. After mixing with {sup 99m}Tc-pertechnetate, {sup 99m}Tc-BnAO-NI injection can be readily prepared. The partition coefficient, radiochemical purity and in vitro stability were determined. Cellular uptake of radiotracers in KHT cells under hypoxia was conducted in a CO{sub 2} incubator at 37 {sup o}C under hypoxia or normoxia. A biodistribution study after intravenous injection of {sup 99m}Tc-BnAO-NI in KHT sarcoma-implanted C3H mice was performed. The effect of pentoxifylline (100 mg/kg) on reducing tumor hypoxia was also studied. Results: The radiochemical purity (RCP) of the {sup 99m}Tc-BnAO-NI preparation was greater than 96% and stable at ambient temperature for 24 h (RCP>90%). The accumulation of {sup 99m}Tc-BnAO-NI and {sup 99m}Tc-BnAO in KHT cells under hypoxia were 3.57 and 4.13-fold higher than those under normoxic environment, indicating unambiguous oxygen-dependent uptakes of these two probes. The distribution of {sup 99m}Tc-BnAO-NI in KHT sarcoma-bearing mice revealed rapid clearance from the blood circulation. The tumor uptake peaked at 2 h post-injection (0.32{+-}0.05%ID/g) with tumor-to-blood and tumor-to-muscle ratios of 10.32 and 3.96, respectively. The effect of pentoxifylline on the

  18. In vivo near-infrared fluorescence imaging of amyloid-β plaques with a dicyanoisophorone-based probe

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Jia-ying; Zhou, Lin-fu; Li, Yu-kun [School of Bioscience and Bioengineering, South China University of Technology, Guangzhou, 510006 (China); Chen, Shuo-bin [School of Pharmaceutical Science, Sun Yat-sen University, Guangzhou, 510006 (China); Yan, Jin-wu, E-mail: yjw@scut.edu.cn [School of Bioscience and Bioengineering, South China University of Technology, Guangzhou, 510006 (China); Zhang, Lei, E-mail: lzhangce@scut.edu.cn [School of Bioscience and Bioengineering, South China University of Technology, Guangzhou, 510006 (China)

    2017-04-08

    A dicyanoisophorone-based probe with two-photon absorption and NIR emission was developed for the in vivo fluorescence imaging of amyloid-β plaques, which exhibited high selectivity toward Aβ aggregates over other intracellular proteins. The detection limit was calculated to be as low as 109 nM. In vivo imaging studies indicated that the probe could penetrate the blood–brain barrier and label Aβ plaques in the living transgenic mice, and its specific binding to cerebral Aβ plaques was further confirmed by one- and two-photon ex vivo fluorescence imaging. All these results featured its promising application prospects for amyloid-β sensing in basic research and biomedical research. - Highlights: • A two-photon probe (DCIP-1) with NIR emission based on dicyanoisophorone group, for the in vivo fluorescence imaging of amyloid-β plaques, was reported. • The probe showed turn-on fluorescence (13-fold) with a large Stokes shift upon inserting into the hydrophobic pockets of Aβ aggregates. • The in vivo imaging studies indicated that the probe can penetrate the blood–brain barrier efficiently and discriminate APP/PS1 transgenic mice from WT controls.

  19. In vivo near-infrared fluorescence imaging of amyloid-β plaques with a dicyanoisophorone-based probe

    International Nuclear Information System (INIS)

    Zhu, Jia-ying; Zhou, Lin-fu; Li, Yu-kun; Chen, Shuo-bin; Yan, Jin-wu; Zhang, Lei

    2017-01-01

    A dicyanoisophorone-based probe with two-photon absorption and NIR emission was developed for the in vivo fluorescence imaging of amyloid-β plaques, which exhibited high selectivity toward Aβ aggregates over other intracellular proteins. The detection limit was calculated to be as low as 109 nM. In vivo imaging studies indicated that the probe could penetrate the blood–brain barrier and label Aβ plaques in the living transgenic mice, and its specific binding to cerebral Aβ plaques was further confirmed by one- and two-photon ex vivo fluorescence imaging. All these results featured its promising application prospects for amyloid-β sensing in basic research and biomedical research. - Highlights: • A two-photon probe (DCIP-1) with NIR emission based on dicyanoisophorone group, for the in vivo fluorescence imaging of amyloid-β plaques, was reported. • The probe showed turn-on fluorescence (13-fold) with a large Stokes shift upon inserting into the hydrophobic pockets of Aβ aggregates. • The in vivo imaging studies indicated that the probe can penetrate the blood–brain barrier efficiently and discriminate APP/PS1 transgenic mice from WT controls.

  20. Standard-free electron-probe microanalysis of thin films of HTSC-oxide and semiconductors (h<1μm)

    International Nuclear Information System (INIS)

    Kvardakov, A.M.; Mikhajlova, A.Ya.; San'gin, V.P.; Lazarev, V.B.

    1993-01-01

    A simplified variant of the standard-free electron-probe microanalysis is elaborated to carry out rapid analysis of chemical composition of >1μm thickness thin films of high-temperature superconductor oxides and semiconductors on alien substrates. The suggested technique has increased the efficiency of search for optimal conditions of preparation YBa 2 Cu 3 O x thin films existing in magnetron and InSb ion-beam techniques of spraying on SrTiO 3 and α-Al 2 O 3 monocrystal base substrates

  1. The 1:3M geologic map of Mercury: progress and updates

    Science.gov (United States)

    Galluzzi, Valentina; Guzzetta, Laura; Mancinelli, Paolo; Giacomini, Lorenza; Malliband, Christopher C.; Mosca, Alessandro; Wright, Jack; Ferranti, Luigi; Massironi, Matteo; Pauselli, Cristina; Rothery, David A.; Palumbo, Pasquale

    2017-04-01

    After the end of Mariner 10 mission a 1:5M geologic map of seven of the fifteen quadrangles of Mercury [Spudis and Guest, 1988] was produced. The NASA MESSENGER mission filled the gap by imaging 100% of the planet with a global average resolution of 200 m/pixel and this led to the production of a global 1:15M geologic map of the planet [Prockter et al., 2016]. Despite the quality gap between Mariner 10 and MESSENGER images, no global geological mapping project with a scale larger than 1:5M has been proposed so far. Here we present the status of an ongoing project for the geologic mapping of Mercury at an average output scale of 1:3M based on the available MESSENGER data. This project will lead to a fuller grasp of the planet's stratigraphy and surface history. Completing such a product for Mercury is an important goal in preparation for the forthcoming ESA/JAXA BepiColombo mission to aid selection of scientific targets and to provide context for interpretation of new data. At the time of this writing, H02 Victoria [Galluzzi et al., 2016], H03 Shakespeare [Guzzetta et al., 2016] and H04 Raditladi [Mancinelli et al., 2016] have been completed and H05 Hokusai [Rothery et al., 2017], H06 Kuiper [Giacomini et al., 2017], H07 Beethoven and H10 Derain [Malliband et al., 2017] are being mapped. The produced geologic maps were merged using the ESRI ArcGIS software adjusting discontinuous contacts along the quadrangle boundaries. Contact discrepancies were reviewed and discussed among the mappers of adjoining quadrangles in order to match the geological interpretation and provide a unique consistent stratigraphy. At the current stage, more than 20% of Mercury has now a complete 1:3M map and more than 40% of the planet will be covered soon by the maps that are being prepared. This research was supported by the Italian Space Agency (ASI) within the SIMBIOSYS project (ASI-INAF agreement no. I/022/10/0). References Galluzzi V. et al. (2016). Geology of the Victoria Quadrangle (H

  2. The AMEMIYA probe. Theoretical background

    International Nuclear Information System (INIS)

    Belitz, Hans Joahim; Althausen, Bernhard; Uehara, Kazuya; Amemiya, Hiroshi

    2010-01-01

    The present probe was developed in order to measure the temperature T i of positive ions in the scrape-off layer (SOL) of tokamak where T i is usually larger than the electron temperature Ti so that the presheath in front of the probe need not be considered and the ions reach the probe with the thermal velocity. The axis of the cylindrical probe is placed parallel to the magnetic field. The important parameter are L/a, the ratio of the length to the radius of the cylindrical probe and κ, the ratio of the probe radius to (π/4) 1/2 , where is the mean ion Larmor radius. The ion current densities to the side and the end surfaces are expressed by the double integral, which can give an analytical formula with respect to the value of κ. If two electrodes with different lengths are placed parallel to the magnetic field, the difference of current densities can be reduced to κ and hence to Ti. Some examples of the application of the probe to tokamaks, JFT-2M and Textor, are demonstrated. (author)

  3. Preparation and comparative evaluation of 99m Tc-HYNIC-cNGR and 99m Tc-HYNIC-PEG2 -cNGR as tumor-targeting molecular imaging probes.

    Science.gov (United States)

    Vats, Kusum; Satpati, Drishty; Sharma, Rohit; Kumar, Chandan; Sarma, Haladhar Dev; Banerjee, Sharmila

    2018-02-01

    The tripeptide sequence asparagine-glycine-arginine (NGR) specifically recognizes aminopeptidase N (APN or CD13) receptors highly expressed on tumor cells and vasculature. Thus, NGR peptides can precisely deliver therapeutic and diagnostic compounds to CD13 expressing cancer sites. In this regard, 2 NGR peptide ligands, HYNIC-c(NGR) and HYNIC-PEG 2 -c(NGR), were synthesized, radiolabeled with 99m Tc, and evaluated in CD13-positive human fibrosarcoma HT-1080 tumor xenografts. The radiotracers, 99m Tc-HYNIC-c(NGR) and 99m Tc-HYNIC-PEG 2 -c(NGR), could be prepared in approximately 95% radiochemical purity and exhibited excellent in vitro and in vivo stability. The radiotracers were hydrophilic in nature with log P values being -2.33 ± 0.05 and -2.61 ± 0.08. The uptake of 2 radiotracers 99m Tc-HYNIC-c(NGR) and 99m Tc-HYNIC-PEG 2 -c(NGR) was similar in nude mice bearing human fibrosarcoma HT-1080 tumor xenografts, which was significantly reduced (P Tc-labeled HYNIC peptide could not be modulated through introduction of PEG 2 unit, thus posing a challenge for studies with other linkers towards enhanced tumor uptake and retention. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Langmuir probe measurement of the bismuth plasma plume formed by an extreme-ultraviolet pulsed laser

    International Nuclear Information System (INIS)

    Pira, P; Burian, T; Kolpaková, A; Tichý, M; Kudrna, P; Daniš, S; Wild, J; Juha, L; Lančok, J; Vyšín, L; Civiš, S; Zelinger, Z; Kubát, P

    2014-01-01

    Properties of the plasma plume produced on a bismuth (Bi) target irradiated by a focused extreme-ultraviolet (XUV) capillary-discharge laser beam were investigated. Langmuir probes were used in both single- and double-probe arrangements to determine the electron temperature and the electron density, providing values of 1–3 eV and ∼10 13 –10 14  m −3 , respectively. Although the temperatures seem to be comparable with values obtained in ablation plasmas produced by conventional, long-wavelength lasers, the density is significantly lower. This finding indicates that the desorption-like phenomena are responsible for the plume formation rather than the ablation processes. A very thin Bi film was prepared on an MgO substrate by pulsed XUV laser deposition. The non-uniform, sub-monolayer character of the deposited bismuth film confirms the Langmuir probe's observation of the desorption-like erosion induced by the XUV laser on the primary Bi target. (paper)

  5. Novel high-resolution temperature probe for radiofrequency dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Schuderer, Juergen [Foundation for Research on Information Technologies in Society (IT' IS), Integrated Systems Laboratory IIS, Swiss Federal Institute of Technology (ETH), CH-8092 Zurich (Switzerland); Schmid, Thomas [Schmid and Partner Engineering AG, 8004 Zurich (Switzerland); Urban, Gerald [IMTEK, Albert-Ludwigs University Freiburg, 79110 Freiburg (Germany); Samaras, Theodoros [Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Kuster, Niels [Foundation for Research on Information Technologies in Society (IT' IS), Integrated Systems Laboratory IIS, Swiss Federal Institute of Technology (ETH), CH-8092 Zurich (Switzerland)

    2004-03-21

    A novel integrated thermistor probe for temperature evaluations in radiofrequency-heated environments was realized. The probe's sensitive area is based on a highly resistive 50 {mu}m x 100 {mu}m layer of amorphous germanium processed on a glass tip. The small dimensions allow measurements with a distance as close as 150 {mu}m from solid boundaries. Due to its high temperature resolution of 4 mK and its short response time of the order of 10 ms, the sensor is very well suited for dosimetric measurements in strong absorption gradients. The influence of radiofrequency (RF) electric fields on the signal is minimized due to the high resistance of the sensor and the leads. The probe was successfully used to determine the highly nonuniform absorption distribution resulting from the RF exposure of cell cultures placed in Petri dishes. (note)

  6. Novel high-resolution temperature probe for radiofrequency dosimetry

    International Nuclear Information System (INIS)

    Schuderer, Juergen; Schmid, Thomas; Urban, Gerald; Samaras, Theodoros; Kuster, Niels

    2004-01-01

    A novel integrated thermistor probe for temperature evaluations in radiofrequency-heated environments was realized. The probe's sensitive area is based on a highly resistive 50 μm x 100 μm layer of amorphous germanium processed on a glass tip. The small dimensions allow measurements with a distance as close as 150 μm from solid boundaries. Due to its high temperature resolution of 4 mK and its short response time of the order of 10 ms, the sensor is very well suited for dosimetric measurements in strong absorption gradients. The influence of radiofrequency (RF) electric fields on the signal is minimized due to the high resistance of the sensor and the leads. The probe was successfully used to determine the highly nonuniform absorption distribution resulting from the RF exposure of cell cultures placed in Petri dishes. (note)

  7. Quantitative measurement of exchange dynamics in proteins via {sup 13}C relaxation dispersion of {sup 13}CHD{sub 2}-labeled samples

    Energy Technology Data Exchange (ETDEWEB)

    Rennella, Enrico; Schuetz, Anne K.; Kay, Lewis E., E-mail: kay@pound.med.utoronto.ca [University of Toronto, Departments of Molecular Genetics, Biochemistry and Chemistry (Canada)

    2016-06-15

    Methyl groups have emerged as powerful probes of protein dynamics with timescales from picoseconds to seconds. Typically, studies involving high molecular weight complexes exploit {sup 13}CH{sub 3}- or {sup 13}CHD{sub 2}-labeling in otherwise highly deuterated proteins. The {sup 13}CHD{sub 2} label offers the unique advantage of providing {sup 13}C, {sup 1}H and {sup 2}H spin probes, however a disadvantage has been the lack of an experiment to record {sup 13}C Carr–Purcell–Meiboom–Gill relaxation dispersion that monitors millisecond time-scale dynamics, implicated in a wide range of biological processes. Herein we develop an experiment that eliminates artifacts that would normally result from the scalar coupling between {sup 13}C and {sup 2}H spins that has limited applications in the past. The utility of the approach is established with a number of applications, including measurement of ms dynamics of a disease mutant of a 320 kDa p97 complex.

  8. Temporal asthma patterns using repeated questionnaires over 13 years in a large French cohort of women.

    Directory of Open Access Journals (Sweden)

    Margaux Sanchez

    Full Text Available Variable expression is one aspect of the heterogeneity of asthma. We aimed to define a variable pattern, which is relevant in general health epidemiological cohorts. Our objectives were to assess whether: 1 asthma patterns defined using simple asthma questions through repeated measurements could reflect disease variability 2 these patterns may further be classified according to asthma severity/control. Among 70,428 French women, we used seven questionnaires (1992-2005 and a comprehensive reimbursement database (2004-2009 to define three reliable asthma patterns based on repeated positive answers to the ever asthma attack question: "never asthma" (n = 64,061; "inconsistent" ("yes" followed by "no", n = 3,514; "consistent" (fully consistent positive answers, n = 2,853. The "Inconsistent" pattern was related to both long-term (childhood-onset asthma with remission in adulthood and short-term (reported asthma attack in the last 12 months, associated with asthma medication asthma variability, showing that repeated questions are relevant markers of the variable expression of asthma. Furthermore, in this pattern, the number of positive responses (1992-2005 predicted asthma drug consumption in subsequent years, a marker of disease severity. The "Inconsistent" pattern is a phenotype that may capture the variable expression of asthma. Repeated answers, even to a simple question, are too often neglected.

  9. A novel rat genomic simple repeat DNA with RNA-homology shows triplex (H-DNA)-like structure and tissue-specific RNA expression

    International Nuclear Information System (INIS)

    Dey, Indranil; Rath, Pramod C.

    2005-01-01

    Mammalian genome contains a wide variety of repetitive DNA sequences of relatively unknown function. We report a novel 227 bp simple repeat DNA (3.3 DNA) with a d {(GA) 7 A (AG) 7 } dinucleotide mirror repeat from the rat (Rattus norvegicus) genome. 3.3 DNA showed 75-85% homology with several eukaryotic mRNAs due to (GA/CU) n dinucleotide repeats by nBlast search and a dispersed distribution in the rat genome by Southern blot hybridization with [ 32 P]3.3 DNA. The d {(GA) 7 A (AG) 7 } mirror repeat formed a triplex (H-DNA)-like structure in vitro. Two large RNAs of 9.1 and 7.5 kb were detected by [ 32 P]3.3 DNA in rat brain by Northern blot hybridization indicating expression of such simple sequence repeats at RNA level in vivo. Further, several cDNAs were isolated from a rat cDNA library by [ 32 P]3.3 DNA probe. Three such cDNAs showed tissue-specific RNA expression in rat. pRT 4.1 cDNA showed strong expression of a 2.39 kb RNA in brain and spleen, pRT 5.5 cDNA showed strong expression of a 2.8 kb RNA in brain and a 3.9 kb RNA in lungs, and pRT 11.4 cDNA showed weak expression of a 2.4 kb RNA in lungs. Thus, genomic simple sequence repeats containing d (GA/CT) n dinucleotides are transcriptionally expressed and regulated in rat tissues. Such d (GA/CT) n dinucleotide repeats may form structural elements (e.g., triplex) which may be sites for functional regulation of genomic coding sequences as well as RNAs. This may be a general function of such transcriptionally active simple sequence repeats widely dispersed in mammalian genome

  10. Dual-Labeled Near-Infrared/99mTc Imaging Probes Using PAMAM-Coated Silica Nanoparticles for the Imaging of HER2-Expressing Cancer Cells

    Directory of Open Access Journals (Sweden)

    Haruka Yamaguchi

    2016-07-01

    Full Text Available We sought to develop dual-modality imaging probes using functionalized silica nanoparticles to target human epidermal growth factor receptor 2 (HER2-overexpressing breast cancer cells and achieve efficient target imaging of HER2-expressing tumors. Polyamidoamine-based functionalized silica nanoparticles (PCSNs for multimodal imaging were synthesized with near-infrared (NIR fluorescence (indocyanine green (ICG and technetium-99m (99mTc radioactivity. Anti-HER2 antibodies were bound to the labeled PCSNs. These dual-imaging probes were tested to image HER2-overexpressing breast carcinoma cells. In vivo imaging was also examined in breast tumor xenograft models in mice. SK-BR3 (HER2 positive cells were imaged with stronger NIR fluorescent signals than that in MDA-MB231 (HER2 negative cells. The increased radioactivity of the SK-BR3 cells was also confirmed by phosphor imaging. NIR images showed strong fluorescent signals in the SK-BR3 tumor model compared to muscle tissues and the MDA-MB231 tumor model. Automatic well counting results showed increased radioactivity in the SK-BR3 xenograft tumors. We developed functionalized silica nanoparticles loaded with 99mTc and ICG for the targeting and imaging of HER2-expressing cells. The dual-imaging probes efficiently imaged HER2-overexpressing cells. Although further studies are needed to produce efficient isotope labeling, the results suggest that the multifunctional silica nanoparticles are a promising vehicle for imaging specific components of the cell membrane in a dual-modality manner.

  11. Blue objects in the vicinity of M13. 1

    International Nuclear Information System (INIS)

    Oganesyan, Eh.Ya.

    1978-01-01

    Presented are photometric data in the UBV system for 225 objects in the region of 16 square degrees in size, adjacent to M13 cluster. ''Two-colour diagram'' and ''colour-luminosity'' diagram are built, and on their basis analysis of the data obtained is made. Half the objects investigated are subdwarfs. Among others there are white - blue dwarfs conventional stars of the main sequence stars, halo stars, stars of globular clusters and objects, which might be of extragalactic nature. On the basis of object distribution as to brightness and colour, and also according to their visible distribution several different groups can be singled out. Several variable stars are also found as a result of photometric investigation

  12. Alignment of mapping system for magnet cyclotron DECY-13

    International Nuclear Information System (INIS)

    Idrus Abdul Kudus; Taufik; Kurnia Wibowo

    2016-01-01

    A cyclotron is composed of some main and specific components, such as magnet system, ion source, RF system and extractor. A magnet is one of important component in a cyclotron that serves as ion beam bending so the ion beam trajectory is circular. Magnet design should with the requirement of cyclotron that proton energy is 13 MeV. In the construction of the cyclotron magnet, a mapping tool of the magnetic field is required for analysis in shimming process in order to optimize the magnetic field. The magnetic field mapping process is carried out in the median plane of the magnet poles. The magnetic field mapping is carried out repeatedly during the shimming process. During this process, the mapping tool is possible to experience a shift or change in position, for that it is necessary to alignment in order to make sure that the probe is in the median plane of magnet poles and to ensure their positions are always the same on each repetition mapping. During this process, it is possible to experience a shift mapping tool or change the position, for this it is needed to process alignment to ensure the position of the probe is in the median plane magnetic poles and ensure their positions are always the same on each repetition mapping. Alignment on the mapping tool are the height position, zeroing tesla meter and two hall probe mapping. The parameters form the basis for magnetic field measurements based on the three elements: an alignment system on the engine mapping, mapping tool reference point and stage movement of x-y coordinates. Shifts occur due to change in elevation mapping tool table and center coordinates x and y in the mapping process. Changes made to shift mapping coordinates can be shifted as far as 1 to 2 mm for each hall probe in the x and y coordinates with altitude changes 0.05° mapping table and measurement of tesla meter changes in 0.002 T. (author)

  13. 1.3μm low threshold distributed feedback lasers for high bit-rate applications

    International Nuclear Information System (INIS)

    Artigue, C.; Louis, Y.; Padioleau, C.; Poingt, F.; Sigogne, D.; Starck, C.; Benoit, J.

    1985-01-01

    A low threshold current (≅ 30 mA) 1.3μm (InGaAsP) second order DFB laser with a ridge structure made by liquid phase epitaxy is reported. The low threshold results from: optimized heterostructure and grating profile, good tuning of the DFB wavelength with the peak gain wavelength, and the proper LPE regrowth conditions on the grating

  14. Solar Probe Plus: Report of the Science and Technology Definition Team

    Science.gov (United States)

    2008-01-01

    Solar Probe+ will be an extraordinary and historic mission, exploring what is arguably the last region of the solar system to be visited by a spacecraft, the Sun s outer atmosphere or corona as it extends out into space. Approaching as close as 9.5 RS* (8.5 RS above the Sun s surface), Solar Probe+ will repeatedly sample the near-Sun environment, revolutionizing our knowledge and understanding of coronal heating and of the origin and evolution of the solar wind and answering critical questions in heliophysics that have been ranked as top priorities for decades. Moreover, by making direct, in-situ measurements of the region where some of the most hazardous solar energetic particles are energized, Solar Probe+ will make a fundamental contribution to our ability to characterize and forecast the radiation environment in which future space explorers will work and live.

  15. Study of probe-sample distance for biomedical spectra measurement

    Directory of Open Access Journals (Sweden)

    Li Lei

    2011-11-01

    Full Text Available Abstract Background Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. Method In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in designing fiber optic probes for biomedical spectra measurement. This model was in general applicable to probes with single or multiple fibers at an arbitrary incident angle. In order to demonstrate the theory, a fluorescence spectrometer was used to measure the fluorescence of human finger skin at various probe-sample distances. The fluorescence spectrum and the total fluorescence intensity were recorded. Results The theoretical results show that for single fiber probes, contact measurement always provides the best results. While for multi-fiber probes, there is an optimal probe distance. When a 400- μm excitation fiber is used to deliver the light to the skin and another six 400- μm fibers surrounding the excitation fiber are used to collect the fluorescence signal, the experimental results show that human finger skin has very strong fluorescence between 475 nm and 700 nm under 450 nm excitation. The fluorescence intensity is heavily dependent on the probe-sample distance and there is an optimal probe distance. Conclusions We investigated a number of probe-sample configurations and found that contact measurement could be the primary choice for single-fiber probes, but was very inefficient for multi-fiber probes. There was an optimal probe-sample distance for multi-fiber probes. By carefully choosing the probe-sample distance, the collection efficiency could be enhanced by 5-10 times. Our experiments demonstrated that the experimental results of the probe-sample distance dependence of collection efficiency in multi-fiber probes were in general agreement with our theory.

  16. An interchangeable scanning Hall probe/scanning SQUID microscope

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin [Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Chen, Tse-Jun; Wang, M. J. [Institute of Astronomy and Astrophysics, Academia Sinica, Taipei 10617, Taiwan (China); Ling, D. C. [Department of Physics, Tamkang University, Tamsui Dist., New Taipei City 25137, Taiwan (China); Chi, C. C.; Chen, Jeng-Chung [Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, Hsinchu 30013, Taiwan (China)

    2014-08-15

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

  17. NCBI nr-aa BLAST: CBRC-HSAP-13-0000 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-HSAP-13-0000 ref|XP_001563383.1| hypothetical repeat protein [Leishmania brazil...iensis] emb|CAM37564.1| hypothetical repeat protein [Leishmania braziliensis] XP_001563383.1 1e-44 30% ...

  18. Electron spin resonance spectroscopy for immunoassay using iron oxide nanoparticles as probe.

    Science.gov (United States)

    Jiang, Jia; Tian, Sizhu; Wang, Kun; Wang, Yang; Zang, Shuang; Yu, Aimin; Zhang, Ziwei

    2018-02-01

    With the help of iron oxide nanoparticles, electron spin resonance spectroscopy (ESR) was applied to immunoassay. Iron oxide nanoparticles were used as the ESR probe in order to achieve an amplification of the signal resulting from the large amount of Fe 3+ ion enclosed in each nanoparticle. Rabbit IgG was used as antigen to test this method. Polyclonal antibody of rabbit IgG was used as antibody to detect the antigen. Iron oxide nanoparticle with a diameter of either 10 or 30 nm was labeled to the antibody, and Fe 3+ in the nanoparticle was probed for ESR signal. The sepharose beads were used as solid phase to which rabbit IgG was conjugated. The nanoparticle-labeled antibody was first added in the sample containing antigen, and the antigen-conjugated sepharose beads were then added into the sample. The nanoparticle-labeled antibody bound to the antigen on sepharose beads was separated from the sample by centrifugation and measured. We found that the detection ranges of the antigen obtained with nanoparticles of different sizes were different because the amount of antibody on nanoparticles of 10 nm was about one order of magnitude higher than that on nanoparticles of 30 nm. When 10 nm nanoparticle was used as probe, the upper limit of detection was 40.00 μg mL -1 , and the analytical sensitivity was 1.81 μg mL -1 . When 30 nm nanoparticle was used, the upper limit of detection was 3.00 μg mL -1 , and the sensitivity was 0.014 and 0.13 μg mL -1 depending on the ratio of nanoparticle to antibody. Graphical abstract Schematic diagram of procedure and ESR spectra.

  19. Repeated Predictable Stress Causes Resilience against Colitis-Induced Behavioral Changes in Mice

    Directory of Open Access Journals (Sweden)

    Ahmed M Hassan

    2014-11-01

    Full Text Available Inflammatory bowel disease is associated with an increased risk of mental disorders and can be exacerbated by stress. In this study which was performed with male 10-week old C57Bl/6N mice, we used dextran sulfate sodium (DSS-induced colitis to evaluate behavioral changes caused by intestinal inflammation, to assess the interaction between repeated psychological stress (water avoidance stress, WAS and colitis in modifying behavior, and to analyze neurochemical correlates of this interaction. A 7-day treatment with DSS (2 % in drinking water decreased locomotion and enhanced anxiety-like behavior in the open field test and reduced social interaction. Repeated exposure to WAS for 7 days had little influence on behavior but prevented the DSS-induced behavioral disturbances in the open field and social interaction tests. In contrast, repeated WAS did not modify colon length, colonic myeloperoxidase content and circulating proinflammatory cytokines, parameters used to assess colitis severity. DSS-induced colitis was associated with an increase in circulating neuropeptide Y (NPY, a rise in the hypothalamic expression of cyclooxygenase-2 mRNA and a decrease in the hippocampal expression of NPY mRNA, brain-derived neurotrophic factor mRNA and mineralocorticoid receptor mRNA. Repeated WAS significantly decreased the relative expression of corticotropin-releasing factor mRNA in the hippocampus. The effect of repeated WAS to blunt the DSS-evoked behavioral disturbances was associated with a rise of circulating corticosterone and an increase in the expression of hypothalamic NPY mRNA. These results show that experimental colitis leads to a particular range of behavioral alterations which can be prevented by repeated WAS, a model of predictable chronic stress, while the severity of colitis remains unabated. We conclude that the mechanisms underlying the resilience effect of repeated WAS involves hypothalamic NPY and the hypothalamic-pituitary-adrenal axis.

  20. 8-13 μm spectra of very late type Wolf-Rayet stars

    International Nuclear Information System (INIS)

    Aitken, D.K.; Barlow, M.J.; Roche, P.F.; Spenser, P.M.

    1980-01-01

    8 to 13 μm spectra are presented of the late Wolf-Rayet stars, Ve 2-45 (WC9), CRL 2104 (WC8), He 2-113 (WC10) and CPD-56 0 8032 (WC10). Both WC10 stars show the unidentified feature at 11.25 μm and one of them that at 8.6 μm; their spectra resemble those of some planetary nebulae. These features are absent in the WC8/9 stars, whose spectra, together with their infrared photometric data, can be understood in terms of approximately 900 K blackbody spectra subject to some interstellar silicate absorption and with a small excess beyond 10 μm, perhaps due to SiC grains. The WC10 objects are characterized by much lower dust temperatures and their evolutionary status appears to be very different from that of the WC8/9 stars. (author)

  1. Evaluation of a flow direction probe and a pitot-static probe on the F-14 airplane at high angles of attack and sideslip

    Science.gov (United States)

    Larson, T. J.

    1984-01-01

    The measurement performance of a hemispherical flow-angularity probe and a fuselage-mounted pitot-static probe was evaluated at high flow angles as part of a test program on an F-14 airplane. These evaluations were performed using a calibrated pitot-static noseboom equipped with vanes for reference flow direction measurements, and another probe incorporating vanes but mounted on a pod under the fuselage nose. Data are presented for angles of attack up to 63, angles of sideslip from -22 deg to 22 deg, and for Mach numbers from approximately 0.3 to 1.3. During maneuvering flight, the hemispherical flow-angularity probe exhibited flow angle errors that exceeded 2 deg. Pressure measurements with the pitot-static probe resulted in very inaccurate data above a Mach number of 0.87 and exhibited large sensitivities with flow angle.

  2. Effects of Single and Repeated Exposure to a 50-Hz 2-mT Electromagnetic Field on Primary Cultured Hippocampal Neurons.

    Science.gov (United States)

    Zeng, Ying; Shen, Yunyun; Hong, Ling; Chen, Yanfeng; Shi, Xiaofang; Zeng, Qunli; Yu, Peilin

    2017-06-01

    The prevalence of domestic and industrial electrical appliances has raised concerns about the health risk of extremely low-frequency magnetic fields (ELF-MFs). At present, the effects of ELF-MFs on the central nervous system are still highly controversial, and few studies have investigated its effects on cultured neurons. Here, we evaluated the biological effects of different patterns of ELF-MF exposure on primary cultured hippocampal neurons in terms of viability, apoptosis, genomic instability, and oxidative stress. The results showed that repeated exposure to 50-Hz 2-mT ELF-MF for 8 h per day after different times in culture decreased the viability and increased the production of intracellular reactive oxidative species in hippocampal neurons. The mechanism was potentially related to the up-regulation of Nox2 expression. Moreover, none of the repeated exposure patterns had significant effects on DNA damage, apoptosis, or autophagy, which suggested that ELF-MF exposure has no severe biological consequences in cultured hippocampal neurons.

  3. A RE-EVALUATION OF THE EVOLVED STARS IN THE GLOBULAR CLUSTER M13

    International Nuclear Information System (INIS)

    Sandquist, Eric L.; Gordon, Mark; Levine, Daniel; Bolte, Michael

    2010-01-01

    We have analyzed photometry from space- and ground-based cameras to identify all bright red giant branch (RGB), horizontal branch (HB), and asymptotic giant branch (AGB) stars within 10' of the center of the globular cluster M13. We identify a modest (7%) population of HB stars redder than the primary peak (including RR Lyrae variables at the blue end of the instability strip) that is somewhat more concentrated to the cluster core than the rest of the evolved stars. We find support for the idea that they are noticeably evolved and in the late stages of depleting helium in their cores. This resolves a disagreement between distance moduli derived from the tip of the RGB and from stars in or near the RR Lyrae instability strip. We identified disagreements between HB model sets on whether stars with T eff ∼ eff ∼ eff ∼ 22, 000 K) as previously suggested. These stars are brighter than other stars of similar color (either redder or bluer), and may be examples of 'early hot flashers' that ignite core helium fusion shortly after leaving the RGB. We used ultraviolet photometry to identify hot post-HB stars, and based on their numbers (relative to canonical AGB stars) we estimate the position on the HB where the morphology of the post-HB tracks change to I ∼ 17.3, between the two peaks in the HB distribution. Concerning the possibility of helium enrichment in M13, we revisited the helium-sensitive R ratio, applying a new method for correcting star counts for larger lifetimes of hot HB stars. We find that M13's R ratio is in agreement with theoretical values for primordial helium abundance Y P = 0.245 and inconsistent with a helium enhancement ΔY = 0.04. The brightness of the HB (both in comparison to the end of the canonical HB and to the tip of the RGB) also appears to rule out the idea that the envelopes of the reddest HB stars have been significantly enriched in helium. The absolute colors of the turnoffs of M3 and M13 potentially may be used to look for

  4. Detection of short repeated genomic sequences on metaphase chromosomes using padlock probes and target primed rolling circle DNA synthesis

    Directory of Open Access Journals (Sweden)

    Stougaard Magnus

    2007-11-01

    Full Text Available Abstract Background In situ detection of short sequence elements in genomic DNA requires short probes with high molecular resolution and powerful specific signal amplification. Padlock probes can differentiate single base variations. Ligated padlock probes can be amplified in situ by rolling circle DNA synthesis and detected by fluorescence microscopy, thus enhancing PRINS type reactions, where localized DNA synthesis reports on the position of hybridization targets, to potentially reveal the binding of single oligonucleotide-size probe molecules. Such a system has been presented for the detection of mitochondrial DNA in fixed cells, whereas attempts to apply rolling circle detection to metaphase chromosomes have previously failed, according to the literature. Methods Synchronized cultured cells were fixed with methanol/acetic acid to prepare chromosome spreads in teflon-coated diagnostic well-slides. Apart from the slide format and the chromosome spreading everything was done essentially according to standard protocols. Hybridization targets were detected in situ with padlock probes, which were ligated and amplified using target primed rolling circle DNA synthesis, and detected by fluorescence labeling. Results An optimized protocol for the spreading of condensed metaphase chromosomes in teflon-coated diagnostic well-slides was developed. Applying this protocol we generated specimens for target primed rolling circle DNA synthesis of padlock probes recognizing a 40 nucleotide sequence in the male specific repetitive satellite I sequence (DYZ1 on the Y-chromosome and a 32 nucleotide sequence in the repetitive kringle IV domain in the apolipoprotein(a gene positioned on the long arm of chromosome 6. These targets were detected with good efficiency, but the efficiency on other target sites was unsatisfactory. Conclusion Our aim was to test the applicability of the method used on mitochondrial DNA to the analysis of nuclear genomes, in particular as

  5. Monitoring of right ventricular function by single probe system (nuclear stethoscope) and sup(81m)Kr

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Ohmine, Hiromi; Kimura, Motomasa

    1982-01-01

    A single probe system (nuclear stethoscope) was developed to evaluate the monitoring of right ventricular function by sup(81m)Kr continuous infusion method. Optimal right ventricular and background positions were determined by position/monitor mode on beat-to-beat basis, and right ventricular ejection fraction (RVEF) was calculated by multi-gated method (MUGA). The correlation coefficient of nuclear stethoscope RVEF and camera-computer RVEF (MUGA) was 0.82, while the correlation coefficient of nuclear stethoscope RVEF and camera-computer RVEF (first-pass method) was 0.64. Therefore, the RVEF by nuclear stethoscope is useful for monitoring of right ventricular function. Clinical applications by sup(81m)Kr and nuclear stethoscope were as follows. 1. Exercise/rest RVEF is an extremely sensitive indicator to discriminate coronary artery disease (RCA occlusion) from normal subjects. 2. Beat-to-beat right ventricular volume response is useful for the monitoring of arrythmia such as atrial fibrillation. (author)

  6. Monitoring of right ventricular function by single probe system (nuclear stethoscope) and sup(81m)Kr

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Ohmine, Hiromi; Kimura, Motomasa [National Cardiovascular Center, Suita, Osaka (Japan)

    1982-12-01

    A single probe system (nuclear stethoscope) was developed to evaluate the monitoring of right ventricular function by sup(81m)Kr continuous infusion method. Optimal right ventricular and background positions were determined by position/monitor mode on beat-to-beat basis, and right ventricular ejection fraction (RVEF) was calculated by multi-gated method (MUGA). The correlation coefficient of nuclear stethoscope RVEF and camera-computer RVEF (MUGA) was 0.82, while the correlation coefficient of nuclear stethoscope RVEF and camera-computer RVEF (first-pass method) was 0.64. Therefore, the RVEF by nuclear stethoscope is useful for monitoring of right ventricular function. Clinical applications by sup(81m)Kr and nuclear stethoscope were as follows. 1. Exercise/rest RVEF is an extremely sensitive indicator to discriminate coronary artery disease (RCA occlusion) from normal subjects. 2. Beat-to-beat right ventricular volume response is useful for the monitoring of arrythmia such as atrial fibrillation.

  7. 1/f Noise Characterization in CMOS Transistors in 0.13μm Technology

    DEFF Research Database (Denmark)

    Citakovic, J.; Stenberg, L J; Andreani, Pietro

    2006-01-01

    Low-frequency noise has been studied on a set of n- and p-channel CMOS transistors fabricated in a 0.13μm technology. Noise measurements have been performed on transistors with different gate lengths operating under wide bias conditions, ranging from weak to strong inversion. Noise origin has been...

  8. Detection of tet(M) and tet(O) using the polymerase chain reaction in bacteria isolated from patients with periodontal disease.

    Science.gov (United States)

    Olsvik, B; Olsen, I; Tenover, F C

    1995-04-01

    The polymerase chain reaction was used to examine 114 tetracycline-resistant anaerobic and facultative anaerobic bacterial isolates from patients with periodontal disease for the tet(M) and tet(O) genes. A 740-base-pair fragment of the tet(M) gene was amplified from 84 of 114 isolates, and a 519-base-pair fragment of the tet(O) gene was amplified from 13 streptococcal isolates. Six of 7 tetracycline-resistant isolates of Veillonella spp. and tetracycline-resistant isolates of Eubacterium spp. (n = 3), Eubacterium saburreum (n = 1), Streptococcus intermedius (n = 5) and Gemella morbillorum (n = 2) all harbored the tet(M) gene. The tet(M) and tet(O) negative as well as selected positive isolates were tested for the tet(K) and tet(L) genes using DNA probes. All isolates of Staphylococcus spp. (n = 11) hybridized with the tet(K) probe. None of the isolates tested hybridized with the probe for tet(L). This is the first report of the tet(M) gene in the facultative bacterium G. morbillorum and in E. saburreum.

  9. Depth Probing Soft X-ray Microprobe (DPSXRM) for High Resolution Probing of Earth's Microstructural Samples

    Science.gov (United States)

    Dikedi, P. N.

    2015-12-01

    The Cambrian explosion; occurrence of landslides in very dry weather conditions; rockslides; dead, shriveled-up and crumbled leaves possessing fossil records with the semblance of well preserved, flat leaves; abundance of trilobite tracks in lower and higher rock layers; and sailing stones are enigmas demanding demystifications. These enigmas could be elucidated when data on soil structure, texture and strength are provided by some device with submicrometre accuracy; for these and other reasons, the design of a Depth Probing Soft X-ray Microprobe (DPSXRM), is being proposed; it is expected to deliver soft X-rays, at spatial resolution, ϛ≥600nm and to probe at the depth of 0.5m in 17s. The microprobe is portable compared to a synchrotron radiation facility (Diamond Light Source has land size of 43,300m2); spatial resolution,ϛ , of the DPSXRM surpasses those of the X-ray Fluorescence microanalysis (10µm), electron microprobe (1-3µm) and ion microprobe (5->30µm); the DPSXRM has allowance for multiple targets. Vanadium and Manganese membranes are proposed owing to respective 4.952KeV VKα1 and 5.899KeV MnKα1 X-rays emitted, which best suits micro-probing of Earth's microstructural samples. Compound systems like the Kirk-Patrick and Baez and Wolter optics, aspheric mirrors like elliptical and parabolic optics, small apertures and Abbe sine condition are employed to reduce or remove astigmatism, obliquity, comatic and spherical aberrations—leading to good image quality. Results show that 5.899KeV MnKα1 and 4.952KeV VKα1 soft X-rays will travel a distance of 2.75mm to form circular patches of radii 2.2mm and 2.95mm respectively. Zone plate with nth zone radius of 1.5mm must be positioned 1.5mm and 2mm from the electron gun if circular patches must be formed from 4.952KeV VKα1 and 5.899KeV MnKα1 soft X-rays respectively. The focal lengths of 0.25μm≤ƒ≤1.50μm and 0.04μm≤ƒ≤0.2μm covered by 4.952KeV VKα1 and 5.899KeV Mn Kα1 soft X-Rays, will

  10. The effect of repeated testing vs repeated practice on skills learning in undergraduate dental education.

    Science.gov (United States)

    Sennhenn-Kirchner, S; Goerlich, Y; Kirchner, B; Notbohm, M; Schiekirka, S; Simmenroth, A; Raupach, T

    2018-02-01

    Recent studies in undergraduate medical education have demonstrated the advantage of repeated testing over repeated practice with regard to knowledge and skills retention. The aim of this study was to investigate whether this "testing effect" also applies to skills retention in undergraduate dental education. In this prospective, randomised controlled trial, fourth-year dental students at Göttingen University Medical Centre participated in a training session on surgical suturing in winter term 2014/2015. Following this, they were either assigned to two sessions of additional skills training (group A) or two sessions of skills assessment with feedback (group B). These sessions were spaced over a period of 4 weeks. Skills retention was assessed in a summative objective structured clinical examination (OSCE) at the end of term, that is 6 months after the initial teaching session. A total of 32 students completed the study. With regard to suturing, OSCE performance was significantly better in group B than group A (81.9±13.1% vs 63.0±15.4%; P=0.001; Cohen's d=1.33). There was no significant OSCE performance difference in the two groups with regard to other learning objectives that were addressed in the end-of-term examination. Thus, the group difference was specific to suturing skills. This is the first study to demonstrate that in dental education, repeated testing produces more favourable skills retention than repeated practice. Test-enhanced learning might be a viable concept for skills retention in undergraduate dentistry education. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Use of moisture probes in building materials industry

    International Nuclear Information System (INIS)

    Hanke, L.

    A neutron probe to be built in the production line was developed for monitoring moisture content of bulk materials and suspensions of all types in the building material industry. The probe is dust- and external moisture-protected. The probe measuring capacity is about 100 l, the mean measurement error is +- 0.008 g water per 1 cm 3 , which for fine sand represents an error of +- 0.3%. The probe is connected via a cable to a measuring instrument showing an electrical value proportional to the measured material moisture content. (Z.M.)

  12. Note: Additionally refined new possibilities of plasma probe diagnostics

    Science.gov (United States)

    Riaby, V. A.; Savinov, V. P.; Masherov, P. E.; Yakunin, V. G.

    2018-03-01

    In two previous Notes published in this journal, a method of measuring probe sheath thickness and ion mass was described using Langmuir probe diagnostics in low pressure xenon plasma close to Maxwellian substance. According to the first Note, this method includes two stages: (i) in a special experiment with known ion mass, the Bohm and Child-Langmuir-Boguslavsky (CLB) equations for cylindrical Langmuir probes used in this xenon plasma were solved jointly to determine the probe sheath thicknesses and Bohm coefficient CBCyl ≈ 1.13; and (ii) in a general experiment, with known CBCyl, the same equations could be solved to obtain the probe sheath thicknesses and the mean ion mass. In the second Note, the (i) stage of this method was refined: the results of the CLB probe sheath model application, which were termed "evaluations," were corrected using the step-front probe sheath model, which was closer to reality in the special experiment with the xenon plasma. This process resulted in a Bohm coefficient of CBCyl ≈ 1.23 for the cylindrical probe. In the present Note, corrected xenon plasma parameters without the influence of the bare probe protective shield were used for the (i) stage of this diagnostic method. This action also refined the Bohm coefficient, lowering it to CBCyl ≈ 0.745 for cylindrical probes. This advance makes the new diagnostics method more objective and reliable.

  13. A search for optical bursts from the repeating fast radio burst FRB 121102

    Science.gov (United States)

    Hardy, L. K.; Dhillon, V. S.; Spitler, L. G.; Littlefair, S. P.; Ashley, R. P.; De Cia, A.; Green, M. J.; Jaroenjittichai, P.; Keane, E. F.; Kerry, P.; Kramer, M.; Malesani, D.; Marsh, T. R.; Parsons, S. G.; Possenti, A.; Rattanasoon, S.; Sahman, D. I.

    2017-12-01

    We present a search for optical bursts from the repeating fast radio burst FRB 121102 using simultaneous observations with the high-speed optical camera ULTRASPEC on the 2.4-m Thai National Telescope and radio observations with the 100-m Effelsberg Radio Telescope. A total of 13 radio bursts were detected, but we found no evidence for corresponding optical bursts in our 70.7-ms frames. The 5σ upper limit to the optical flux density during our observations is 0.33 mJy at 767 nm. This gives an upper limit for the optical burst fluence of 0.046 Jy ms, which constrains the broad-band spectral index of the burst emission to α ≤ -0.2. Two of the radio pulses are separated by just 34 ms, which may represent an upper limit on a possible underlying periodicity (a rotation period typical of pulsars), or these pulses may have come from a single emission window that is a small fraction of a possible period.

  14. Rapid isolation of antibody from a synthetic human antibody library by repeated fluorescence-activated cell sorting (FACS.

    Directory of Open Access Journals (Sweden)

    Sung Sun Yim

    Full Text Available Antibodies and their derivatives are the most important agents in therapeutics and diagnostics. Even after the significant progress in the technology for antibody screening from huge libraries, it takes a long time to isolate an antibody, which prevents a prompt action against the spread of a disease. Here, we report a new strategy for isolating desired antibodies from a combinatorial library in one day by repeated fluorescence-activated cell sorting (FACS. First, we constructed a library of synthetic human antibody in which single-chain variable fragment (scFv was expressed in the periplasm of Escherichia coli. After labeling the cells with fluorescent antigen probes, the highly fluorescent cells were sorted by using a high-speed cell sorter, and these cells were reused without regeneration in the next round of sorting. After repeating this sorting, the positive clones were completely enriched in several hours. Thus, we screened the library against three viral antigens, including the H1N1 influenza virus, Hepatitis B virus, and Foot-and-mouth disease virus. Finally, the potential antibody candidates, which show K(D values between 10 and 100 nM against the target antigens, could be successfully isolated even though the library was relatively small (∼ 10(6. These results show that repeated FACS screening without regeneration of the sorted cells can be a powerful method when a rapid response to a spreading disease is required.

  15. Identification of active dehalorespiring microbial populations in anoxic river sediment by RNA-based stable isotope probing

    Science.gov (United States)

    Kittelmann, S.; Friedrich, M. W.

    2005-12-01

    Tetrachloroethene (perchloroethylene, PCE), a persistent contaminant in aquifers, soils and sediments, can be reductively dechlorinated by anaerobic microorganisms in a process referred to as dehalorespiration. However, the biodiversity of dehalorespiring microorganisms and their distribution especially in pristine environments is largely unexplored. Therefore, the aim of this study was to detect potentially novel PCE-dehalorespiring microorganisms by using stable isotope probing (SIP), a technique that allows to directly identify the function of uncultivated microbial populations. We simulated a PCE contamination by incubating pristine river sediment in the presence of PCE at a steady, low aqueous concentration (20 μM). Dehalogenation activity in microcosms (20 nmol cis-dichloroethene per ml slurry per day formed) was detected already after 4 weeks at 20°C with sediment indigenous electron donors. The microbial community in sediment incubations was probed with 13C-labelled acetate (0.5 mM) as electron donor and carbon source at 15°C for 3 days. After RNA extraction, "heavy" 13C-rRNA and light 12C-rRNA were separated by isopycnic centrifugation, and Bacteria-related populations in gradient fractions were characterised by terminal restriction fragment length polymorphism analysis and cloning. In heavy gradient fractions from the microcosm with PCE, we detected a prominent 506-bp terminal restriction fragment (T-RF) and a few minor T-RFs only. In contrast, in the control without PCE, Bacteria-specific rRNA was restricted to light gradient fractions, and the prominent T-RFs found in the PCE-dechlorinating microcosm were of minor importance. Apparently, 13C-acetate was incorporated into bacterial rRNA more effectively in PCE-respiring microcosms. Thus, rRNA-SIP provides strong evidence for the presence of PCE-dehalorespiring, 13C-acetate-utilising populations in river sediment microcosms. Cloning/sequencing analysis identified the prominent members of the heavy

  16. Ten days of repeated local forearm heating does not affect cutaneous vascular function.

    Science.gov (United States)

    Francisco, Michael A; Brunt, Vienna E; Jensen, Krista Nicole; Lorenzo, Santiago; Minson, Christopher T

    2017-08-01

    The aim of the present study was to determine whether 10 days of repeated local heating could induce peripheral adaptations in the cutaneous vasculature and to investigate potential mechanisms of adaptation. We also assessed maximal forearm blood flow to determine whether repeated local heating affects maximal dilator capacity. Before and after 10 days of heat training consisting of 1-h exposures of the forearm to 42°C water or 32°C water (control) in the contralateral arm (randomized and counterbalanced), we assessed hyperemia to rapid local heating of the skin ( n = 14 recreationally active young subjects). In addition, sequential doses of acetylcholine (ACh, 1 and 10 mM) were infused in a subset of subjects ( n = 7) via microdialysis to study potential nonthermal microvascular adaptations following 10 days of repeated forearm heat training. Skin blood flow was assessed using laser-Doppler flowmetry, and cutaneous vascular conductance (CVC) was calculated as laser-Doppler red blood cell flux divided by mean arterial pressure. Maximal cutaneous vasodilation was achieved by heating the arm in a water-spray device for 45 min and assessed using venous occlusion plethysmography. Forearm vascular conductance (FVC) was calculated as forearm blood flow divided by mean arterial pressure. Repeated forearm heating did not increase plateau percent maximal CVC (CVC max ) responses to local heating (89 ± 3 vs. 89 ± 2% CVC max , P = 0.19), 1 mM ACh (43 ± 9 vs. 53 ± 7% CVC max , P = 0.76), or 10 mM ACh (61 ± 9 vs. 85 ± 7% CVC max , P = 0.37, by 2-way repeated-measures ANOVA). There was a main effect of time at 10 mM ACh ( P = 0.03). Maximal FVC remained unchanged (0.12 ± 0.02 vs. 0.14 ± 0.02 FVC, P = 0.30). No differences were observed in the control arm. Ten days of repeated forearm heating in recreationally active young adults did not improve the microvascular responsiveness to ACh or local heating. NEW & NOTEWORTHY We show for the first time that 10 days of repeated

  17. A new fluorescence/PET probe for targeting intracellular human telomerase reverse transcriptase (hTERT) using Tat peptide-conjugated IgM

    International Nuclear Information System (INIS)

    Jung, Kyung oh; Youn, Hyewon; Kim, Seung Hoo; Kim, Young-Hwa; Kang, Keon Wook; Chung, June-Key

    2016-01-01

    Despite an increasing need for methods to visualize intracellular proteins in vivo, the majority of antibody-based imaging methods available can only detect membrane proteins. The human telomerase reverse transcriptase (hTERT) is an intracellular target of great interest because of its high expression in several types of cancer. In this study, we developed a new probe for hTERT using the Tat peptide. An hTERT antibody (IgG or IgM) was conjugated with the Tat peptide, a fluorescence dye and "6"4Cu. HT29 (hTERT+) and U2OS (hTERT−) were used to visualize the intracellular hTERT. The hTERT was detected by RT-PCR and western blot. Fluorescence signals for hTERT were obtained by confocal microscopy, live cell imaging, and analyzed by Tissue-FAXS. In nude mice, tumors were visualized using the fluorescence imaging devices Maestro™ and PETBOX. In RT-PCR and western blot, the expression of hTERT was detected in HT29 cells, but not in U2OS cells. Fluorescence signals were clearly observed in HT29 cells and in U2OS cells after 1 h of treatment, but signals were only detected in HT29 cells after 24 h. Confocal microscopy showed that 9.65% of U2OS and 78.54% of HT29 cells had positive hTERT signals. 3D animation images showed that the probe could target intranuclear hTERT in the nucleus. In mice models, fluorescence and PET imaging showed that hTERT in HT29 tumors could be efficiently visualized. In summary, we developed a new method to visualize intracellular and intranuclear proteins both in vitro and in vivo. - Highlights: • We developed new probes for imaging hTERT using Tat-conjugated IgM antibodies labeled with a fluorescent dye and radioisotope. • This probes could be used to overcome limitation of conventional antibody imaging system in live cell imaging. • This system could be applicable to monitor intracellular and intranuclear proteins in vitro and in vivo.

  18. A new fluorescence/PET probe for targeting intracellular human telomerase reverse transcriptase (hTERT) using Tat peptide-conjugated IgM

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kyung oh [Department of Nuclear Medicine, Seoul National University College of Medicine (Korea, Republic of); Biomedical Sciences, Seoul National University College of Medicine (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine (Korea, Republic of); Tumor Microenvironment Global Core Research Center, Seoul National University (Korea, Republic of); Youn, Hyewon, E-mail: hwyoun@snu.ac.kr [Department of Nuclear Medicine, Seoul National University College of Medicine (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine (Korea, Republic of); Tumor Microenvironment Global Core Research Center, Seoul National University (Korea, Republic of); Cancer Imaging Center, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Seung Hoo [Department of Nuclear Medicine, Seoul National University College of Medicine (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine (Korea, Republic of); Kim, Young-Hwa [Department of Nuclear Medicine, Seoul National University College of Medicine (Korea, Republic of); Biomedical Sciences, Seoul National University College of Medicine (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine (Korea, Republic of); Kang, Keon Wook [Department of Nuclear Medicine, Seoul National University College of Medicine (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine (Korea, Republic of); Chung, June-Key, E-mail: jkchung@snu.ac.kr [Department of Nuclear Medicine, Seoul National University College of Medicine (Korea, Republic of); Biomedical Sciences, Seoul National University College of Medicine (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine (Korea, Republic of); Tumor Microenvironment Global Core Research Center, Seoul National University (Korea, Republic of)

    2016-08-26

    Despite an increasing need for methods to visualize intracellular proteins in vivo, the majority of antibody-based imaging methods available can only detect membrane proteins. The human telomerase reverse transcriptase (hTERT) is an intracellular target of great interest because of its high expression in several types of cancer. In this study, we developed a new probe for hTERT using the Tat peptide. An hTERT antibody (IgG or IgM) was conjugated with the Tat peptide, a fluorescence dye and {sup 64}Cu. HT29 (hTERT+) and U2OS (hTERT−) were used to visualize the intracellular hTERT. The hTERT was detected by RT-PCR and western blot. Fluorescence signals for hTERT were obtained by confocal microscopy, live cell imaging, and analyzed by Tissue-FAXS. In nude mice, tumors were visualized using the fluorescence imaging devices Maestro™ and PETBOX. In RT-PCR and western blot, the expression of hTERT was detected in HT29 cells, but not in U2OS cells. Fluorescence signals were clearly observed in HT29 cells and in U2OS cells after 1 h of treatment, but signals were only detected in HT29 cells after 24 h. Confocal microscopy showed that 9.65% of U2OS and 78.54% of HT29 cells had positive hTERT signals. 3D animation images showed that the probe could target intranuclear hTERT in the nucleus. In mice models, fluorescence and PET imaging showed that hTERT in HT29 tumors could be efficiently visualized. In summary, we developed a new method to visualize intracellular and intranuclear proteins both in vitro and in vivo. - Highlights: • We developed new probes for imaging hTERT using Tat-conjugated IgM antibodies labeled with a fluorescent dye and radioisotope. • This probes could be used to overcome limitation of conventional antibody imaging system in live cell imaging. • This system could be applicable to monitor intracellular and intranuclear proteins in vitro and in vivo.

  19. Repeated mild traumatic brain injury in female rats increases lipid peroxidation in neurons.

    Science.gov (United States)

    Yates, Nathanael J; Lydiard, Stephen; Fehily, Brooke; Weir, Gillian; Chin, Aaron; Bartlett, Carole A; Alderson, Jacqueline; Fitzgerald, Melinda

    2017-07-01

    Negative outcomes of mild traumatic brain injury (mTBI) can be exacerbated by repeated insult. Animal models of repeated closed-head mTBI provide the opportunity to define acute pathological mechanisms as the number of mTBI increases. Furthermore, little is known about the effects of mTBI impact site, and how this may affect brain function. We use a closed head, weight drop model of mTBI that allows head movement following impact, in adult female rats to determine the role of the number and location of mTBI on brain pathology and behaviour. Biomechanical assessment of two anatomically well-defined mTBI impact sites were used, anterior (bregma) and posterior (lambda). Location of the impact had no significant effect on impact forces (450 N), and the weight impact locations were on average 5.4 mm from the desired impact site. No between location vertical linear head kinematic differences were observed immediately following impact, however, in the 300 ms post-impact, significantly higher mean vertical head displacement and velocity were observed in the mTBI lambda trials. Breaches of the blood brain barrier were observed with three mTBI over bregma, associated with immunohistochemical indicators of damage. However, an increased incidence of hairline fractures of the skull and macroscopic haemorrhaging made bregma an unsuitable impact location to model repeated mTBI. Repeated mTBI over lambda did not cause skull fractures and were examined more comprehensively, with outcomes following one, two or three mTBI or sham, delivered at 1 day intervals, assessed on days 1-4. We observe a mild behavioural phenotype, with subtle deficits in cognitive function, associated with no identifiable neuroanatomical or inflammatory changes. However, an increase in lipid peroxidation in a subset of cortical neurons following two mTBI indicates increasing oxidative damage with repeated injury in female rats, supported by increased amyloid precursor protein immunoreactivity with three m

  20. AT on Buried LPG Tanks Over 13 m3: An Innovative and Practical Solution

    Science.gov (United States)

    Di Fratta, Crescenzo; Ferraro, Antonio; Tscheliesnig, Peter; Lackner, Gerald; Correggia, Vincenzo; Altamura, Nicola

    In Italy, since 2005, techniques based on Acoustic Emission have been introduced for testing of underground LPG tanks up to 13 m3, according to the European standard EN 12818:2004. The testing procedure for these tanks plans to install one or more pairs of sensors inside the "dome" suited for the access to the valves and fittings of the tank, directly on the accessible metal shell. This methodology is not applicable for the underground LPG buried tanks, where it is necessary to install a larger number of AE sensors, in order to cover at 100% the whole tank shell, even at very deep positions. Already in 2004, the European standard EN 12820 (Appendix C - Informative)give the possibility to use Acoustic Emission testing of LPG underground or buried tanks with a capacity exceeding 13 m3, but no technique was specified for the application. In 2008, TÜV AUSTRIA ITALIA - BLU SOLUTIONS srl - Italian company of TÜV AUSTRIA Group - has developed a technique to get access at tank shell, where tank capacity is greater than 13 m3 and its' diameter greater than 3,5 m. This methodology was fully in comply with the provisions of the European Standard EN 12819:2010, becoming an innovative solution widely appreciated and is used in Italy since this time. Currently, large companies and petrochemical plants, at the occurrence of the tank's requalification, have engaged TÜV AUSTRIA ITALIA - BLU SOLUTIONS to install such permanent predispositions, which allow access to the tank shell - test object - with diameters from 4 to 8 m. Through this access, you can install the AE sensors needed to cover at 100% the tank surface and then to perform AE test. In an economic crisis period, this technique is proving a valid and practically applicable answer, in order to reduce inspection costs and downtime by offering a technically advanced solution (AT), increasing the safety of the involved operators, protecting natural resources and the environment.

  1. Identification of metabolically active methanogens in anaerobic digester by DNA Stable-Isotope Probing using 13C-acetate

    Directory of Open Access Journals (Sweden)

    V. Gowdaman

    2015-04-01

    Full Text Available Anaerobic digestion is gaining enormous attention due to the ability to covert organic wastes into biogas, an alternative sustainable energy. Methanogenic community plays a significant role in biogas production and also for proficient functioning of the anaerobic digester. Therefore, this study was carried out to investigate the methanogen diversity of a food waste anaerobic digester. After endogenous respiration, the digester samples were supplemented with isotopes of acetate to enrich methanogen population, and were analyzed using DNA-SIP (Stable-Isotope Probing. Following separation and fractionation of heavy (13C and light (12C DNA, PCR amplification was carried out using archaeal 16S rRNA gene followed by DGGE analysis. Sequencing of the prominent DGGE bands revealed the dominance of Methanocorpusculum labreanum species belonging to hydrogenotrophic Methanomicrobiales, which can produce methane in the presence of H2/CO2 and requires acetate for its growth. This is the first instance where Methanocorpusculum labreanum is being reported as a dominant species in an anaerobic digester operative on food waste.

  2. Expanding probe repertoire and improving reproducibility in human genomic hybridization

    Science.gov (United States)

    Dorman, Stephanie N.; Shirley, Ben C.; Knoll, Joan H. M.; Rogan, Peter K.

    2013-01-01

    Diagnostic DNA hybridization relies on probes composed of single copy (sc) genomic sequences. Sc sequences in probe design ensure high specificity and avoid cross-hybridization to other regions of the genome, which could lead to ambiguous results that are difficult to interpret. We examine how the distribution and composition of repetitive sequences in the genome affects sc probe performance. A divide and conquer algorithm was implemented to design sc probes. With this approach, sc probes can include divergent repetitive elements, which hybridize to unique genomic targets under higher stringency experimental conditions. Genome-wide custom probe sets were created for fluorescent in situ hybridization (FISH) and microarray genomic hybridization. The scFISH probes were developed for detection of copy number changes within small tumour suppressor genes and oncogenes. The microarrays demonstrated increased reproducibility by eliminating cross-hybridization to repetitive sequences adjacent to probe targets. The genome-wide microarrays exhibited lower median coefficients of variation (17.8%) for two HapMap family trios. The coefficients of variations of commercial probes within 300 nt of a repetitive element were 48.3% higher than the nearest custom probe. Furthermore, the custom microarray called a chromosome 15q11.2q13 deletion more consistently. This method for sc probe design increases probe coverage for FISH and lowers variability in genomic microarrays. PMID:23376933

  3. Coordinated hybrid automatic repeat request

    KAUST Repository

    Makki, Behrooz

    2014-11-01

    We develop a coordinated hybrid automatic repeat request (HARQ) approach. With the proposed scheme, if a user message is correctly decoded in the first HARQ rounds, its spectrum is allocated to other users, to improve the network outage probability and the users\\' fairness. The results, which are obtained for single- and multiple-antenna setups, demonstrate the efficiency of the proposed approach in different conditions. For instance, with a maximum of M retransmissions and single transmit/receive antennas, the diversity gain of a user increases from M to (J+1)(M-1)+1 where J is the number of users helping that user.

  4. Short bowel mucosal morphology, proliferation and inflammation at first and repeat STEP procedures.

    Science.gov (United States)

    Mutanen, Annika; Barrett, Meredith; Feng, Yongjia; Lohi, Jouko; Rabah, Raja; Teitelbaum, Daniel H; Pakarinen, Mikko P

    2018-04-17

    Although serial transverse enteroplasty (STEP) improves function of dilated short bowel, a significant proportion of patients require repeat surgery. To address underlying reasons for unsuccessful STEP, we compared small intestinal mucosal characteristics between initial and repeat STEP procedures in children with short bowel syndrome (SBS). Fifteen SBS children, who underwent 13 first and 7 repeat STEP procedures with full thickness small bowel samples at median age 1.5 years (IQR 0.7-3.7) were included. The specimens were analyzed histologically for mucosal morphology, inflammation and muscular thickness. Mucosal proliferation and apoptosis was analyzed with MIB1 and Tunel immunohistochemistry. Median small bowel length increased 42% by initial STEP and 13% by repeat STEP (p=0.05), while enteral caloric intake increased from 6% to 36% (p=0.07) during 14 (12-42) months between the procedures. Abnormal mucosal inflammation was frequently observed both at initial (69%) and additional STEP (86%, p=0.52) surgery. Villus height, crypt depth, enterocyte proliferation and apoptosis as well as muscular thickness were comparable at first and repeat STEP (p>0.05 for all). Patients, who required repeat STEP tended to be younger (p=0.057) with less apoptotic crypt cells (p=0.031) at first STEP. Absence of ileocecal valve associated with increased intraepithelial leukocyte count and reduced crypt cell proliferation index (pSTEP. Persistent inflammation and lacking mucosal growth may contribute to continuing bowel dysfunction in SBS children, who require repeat STEP procedure, especially after removal of the ileocecal valve. Level IV, retrospective study. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. M13 Bacteriophage/Silver Nanowire Surface-Enhanced Raman Scattering Sensor for Sensitive and Selective Pesticide Detection.

    Science.gov (United States)

    Koh, Eun Hye; Mun, ChaeWon; Kim, ChunTae; Park, Sung-Gyu; Choi, Eun Jung; Kim, Sun Ho; Dang, Jaejeung; Choo, Jaebum; Oh, Jin-Woo; Kim, Dong-Ho; Jung, Ho Sang

    2018-03-28

    A surface-enhanced Raman scattering (SERS) sensor comprising silver nanowires (AgNWs) and genetically engineered M13 bacteriophages expressing a tryptophan-histidine-tryptophan (WHW) peptide sequence (BPWHW) was fabricated by simple mixing of BPWHW and AgNW solutions, followed by vacuum filtration onto a glass-fiber filter paper (GFFP) membrane. The AgNWs stacked on the GFFP formed a high density of SERS-active hot spots at the points of nanowire intersections, and the surface-coated BPWHW functioned as a bioreceptor for selective pesticide detection. The BPWHW-functionalized AgNW (BPWHW/AgNW) sensor was characterized by scanning electron microscopy, confocal scanning fluorescence microscopy, atomic force microscopy, and Fourier transform infrared spectroscopy. The Raman signal enhancement and the selective pesticide SERS detection properties of the BPWHW/AgNW sensor were investigated in the presence of control substrates such as wild-type M13 bacteriophage-decorated AgNWs (BPWT/AgNW) and undecorated AgNWs (AgNW). The BPWHW/AgNW sensor exhibited a significantly higher capture capability for pesticides, especially paraquat (PQ), than the control SERS substrates, and it also showed a relatively higher selectivity for PQ than for other bipyridylium pesticides such as diquat and difenzoquat. Furthermore, as a field application test, PQ was detected on the surface of PQ-pretreated apple peels, and the results demonstrated the feasibility of using a paper-based SERS substrate for on-site residual pesticide detection. The developed M13 bacteriophage-functionalized AgNW SERS sensor might be applicable for the detection of various pesticides and chemicals through modification of the M13 bacteriophage surface peptide sequence.

  6. Probiotic and anti-inflammatory potential of Lactobacillus rhamnosus 4B15 and Lactobacillus gasseri 4M13 isolated from infant feces.

    Science.gov (United States)

    Oh, Nam Su; Joung, Jae Yeon; Lee, Ji Young; Kim, Younghoon

    2018-01-01

    A total of 22 Lactobacillus strains, which were isolated from infant feces were evaluated for their probiotic potential along with resistance to low pH and bile salts. Eight isolates (L. reuteri 3M02 and 3M03, L. gasseri 4M13, 4R22, 5R01, 5R02, and 5R13, and L. rhamnosus 4B15) with high tolerance to acid and bile salts, and ability to adhere to the intestine were screened from 22 strains. Further, functional properties of 8 Lactobacillus strains, such as anti-oxidation, inhibition of α-glucosidase activity, cholesterol-lowering, and anti-inflammation were evaluated. The properties were strain-specific. Particularly, two strains of L. rhamnosus, 4B15 (4B15) and L. gasseri 4M13 (4M13) showed considerably higher anti-oxidation, inhibition of α-glucosidase activity, and cholesterol-lowering, and greater inhibition of nitric oxide production than other strains. Moreover, the two selected strains substantially inhibited the release of inflammatory mediators such as TNF-α, IL-6, IL-1β, and IL-10 stimulated the treatment of RAW 264.7 macrophages with LPS. In addition, whole genome sequencing and comparative genomic analysis of 4B15 and 4M13 indicated them as novel genomic strains. These results suggested that 4B15 and 4M13 showed the highest probiotic potential and have an impact on immune health by modulating pro-inflammatory cytokines.

  7. Probiotic and anti-inflammatory potential of Lactobacillus rhamnosus 4B15 and Lactobacillus gasseri 4M13 isolated from infant feces.

    Directory of Open Access Journals (Sweden)

    Nam Su Oh

    Full Text Available A total of 22 Lactobacillus strains, which were isolated from infant feces were evaluated for their probiotic potential along with resistance to low pH and bile salts. Eight isolates (L. reuteri 3M02 and 3M03, L. gasseri 4M13, 4R22, 5R01, 5R02, and 5R13, and L. rhamnosus 4B15 with high tolerance to acid and bile salts, and ability to adhere to the intestine were screened from 22 strains. Further, functional properties of 8 Lactobacillus strains, such as anti-oxidation, inhibition of α-glucosidase activity, cholesterol-lowering, and anti-inflammation were evaluated. The properties were strain-specific. Particularly, two strains of L. rhamnosus, 4B15 (4B15 and L. gasseri 4M13 (4M13 showed considerably higher anti-oxidation, inhibition of α-glucosidase activity, and cholesterol-lowering, and greater inhibition of nitric oxide production than other strains. Moreover, the two selected strains substantially inhibited the release of inflammatory mediators such as TNF-α, IL-6, IL-1β, and IL-10 stimulated the treatment of RAW 264.7 macrophages with LPS. In addition, whole genome sequencing and comparative genomic analysis of 4B15 and 4M13 indicated them as novel genomic strains. These results suggested that 4B15 and 4M13 showed the highest probiotic potential and have an impact on immune health by modulating pro-inflammatory cytokines.

  8. Spitzer Secondary Eclipses of HAT-P-13b

    Science.gov (United States)

    Hardy, Ryan A.; Harrington, J.; Hardin, M. R.; Madhusudhan, N.; Cubillos, P.; Blecic, J.; Bakos, G.; Hartman, J. D.

    2013-10-01

    HAT-P-13 b is a transiting hot Jupiter with a slightly eccentric orbit (e = 0.010) inhabiting a two-planet system. The two-planet arrangement provides an opportunity to probe the interior structure of HAT-P-13b. Under equilibrium-tide theory and confirmation that the apsides of planets b and c are in alignment, a measurement of the planet's eccentricity can be related to the planet's tidal Love number k2, which describes the central condensation of the planet's mass and its deformation under tidal effects. A measurement of k2 could constrain interior models of HAT-P-13b. HAT-P-13b's orbit is configured favorably for refinement of the eccentricity by secondary eclipse timing observations, which provide direct measurements of ecosω. In 2010, Spitzer observed two secondary eclipses of HAT-P-13b in the 3.6- and 4.5-μm IRAC bandpasses. We present secondary eclipse times and depths; joint models of the HAT-P-13 system that incorporate transit photometry and radial velocity data; and constraints on the atmospheric chemistry of HAT-P-13b that suggest solar-abundance composition without a thermal inversion. Spitzer is operated by the Jet Propulsion Laboratory, California Institute of Technology, under a contract with NASA, which provided support for this work. This work was supported in part by NASA Planetary Atmospheres Grant NNX13AF38G.

  9. Directional rf probe for measurement of conductivity of flowing plasmas

    International Nuclear Information System (INIS)

    Jayakumar, R.; Chakravarthy, D.P.; Rohatgi, V.K.

    1977-01-01

    An electrodeless immersible rf probe for measurement of plasma conductivity in the range 0.01 to 100 mho/m has been designed and fabricated. The probe, with an overall diameter of 11 mm, employs unidirectional electromagnetic field lines which reduce the inaccuracies caused by insertion of the probe in a flowing plasma. In the range studied the probe output shows a linear relationship with the conductivity of the medium. Such probes are of interest in the study of MHD and reentry plasmas

  10. Chicken microsatellite markers isolated from libraries enriched for simple tandem repeats.

    Science.gov (United States)

    Gibbs, M; Dawson, D A; McCamley, C; Wardle, A F; Armour, J A; Burke, T

    1997-12-01

    The total number of microsatellite loci is considered to be at least 10-fold lower in avian species than in mammalian species. Therefore, efficient large-scale cloning of chicken microsatellites, as required for the construction of a high-resolution linkage map, is facilitated by the construction of libraries using an enrichment strategy. In this study, a plasmid library enriched for tandem repeats was constructed from chicken genomic DNA by hybridization selection. Using this technique the proportion of recombinant clones that cross-hybridized to probes containing simple tandem repeats was raised to 16%, compared with < 0.1% in a non-enriched library. Primers were designed from 121 different sequences. Polymerase chain reaction (PCR) analysis of two chicken reference pedigrees enabled 72 loci to be localized within the collaborative chicken genetic map, and at least 30 of the remaining loci have been shown to be informative in these or other crosses.

  11. Synthesis of dispersive iron or iron–silver nanoparticles on engineered capsid pVIII of M13 virus with electronegative terminal peptides

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Shuai; Nakano, Kazuhiko; Zhang, Shu-liang; Yu, Hui-min, E-mail: yuhm@tsinghua.edu.cn [Tsinghua University, Key Laboratory of Industrial Biocatalysis of the Ministry of Education, Department of Chemical Engineering (China)

    2015-10-15

    M13 is a filamentous Escherichia coli virus covered with five types of capsid proteins, in which pVIII with ∼2700 copies was around the cylindered surface and pIII with five copies located at one end of the phage particle. The pIII-engineered M13 phages with enhanced binding specificity toward Fe were screened after five rounds of biopanning, and the one containing ATPTVAMSLSPL peptide at pIII-terminus was selected for mediated synthesis of zero valent (ZV) Fe nanoparticles (NPs) with the wild M13 as control. Under a reducing environment, uniformly dispersed ZVFeNPs with diameter of 5–10 nm were both synthesized and the morphologies after annealing were confirmed to be face-centered cubic type. The synthesized FeNPs mediated by the two phages showed no significant difference, revealing that the pVIII capsid did dominant contribution to metal binding in comparison with the pIII. A novel pVIII-engineered M13 containing AAEEEDPAK at terminus, named as 4ED-pVIII-M13, was constructed and it carried one more negatively charged residue than the wild one (AEGDDPAK). Metal adsorption quantification showed that the binding affinity of the 4ED-pVIII-M13 toward Ag and Ni ions improved to 62 and 18 % from original 21 and 6 %, respectively. The binding affinity toward Fe remained constant (∼85 %). ZVFe–Ag bi-NPs were successfully synthesized through mediation of 4ED-pVIII-M13. Particularly, the Fe:Ag ratio in the bi-NPs was conveniently controlled through changing the molar concentration of FeCl{sub 2} and AgNO{sub 3} solution before reduction.

  12. New Fluorescence Probes for Biomolecules

    Directory of Open Access Journals (Sweden)

    Katarzyna Jurek

    2015-07-01

    Full Text Available Steady state fluorescence measurements have been used for the investigation of interaction between the bovine serum albumin (BSA and fluorescence probes: 3-hydroxy-2,4- bis[(3-methyl-1,3-benzoxazol-2(3H-ylidenemethyl]cyclobut-2-en-1-one (SQ6, 3-hydroxy- 2,4-bis[(3-methyl-1,3-benzothiazol-2(3H-ylidenemethyl]cyclobut-2-en-1-one (SQ7 and 3-hydroxy-2,4-bis[(1,3,3-trimethyl-1,3-dihydro-2H-indol-2-ylidenemethyl]cyclobut-2-en-1-one (SQ8. The binding constant between bovine serum albumin and squarine dyes has been determined by using both the Benesi-Hildebrand and Stern-Volmer equations. The negative value of free energy change indicates the existence of a spontaneous complexation process of BSA with squarine dyes.

  13. Interpretation of plasma impurity deposition probes. Analytic approximation

    Science.gov (United States)

    Stangeby, P. C.

    1987-10-01

    Insertion of a probe into the plasma induces a high speed flow of the hydrogenic plasma to the probe which, by friction, accelerates the impurity ions to velocities approaching the hydrogenic ion acoustic speed, i.e., higher than the impurity ion thermal speed. A simple analytic theory based on this effect provides a relation between impurity fluxes to the probe Γimp and the undisturbed impurity ion density nimp, with the hydrogenic temperature and density as input parameters. Probe size also influences the collection process and large probes are found to attract a higher flux density than small probes in the same plasma. The quantity actually measured, cimp, the impurity atom surface density (m-2) net-deposited on the probe, is related to Γimp and thus to nimp by taking into account the partial removal of deposited material caused by sputtering and the redeposition process.

  14. The membrane-bound form of gene 9 minor coat protein of bacteriophage M13

    NARCIS (Netherlands)

    Houbiers, M.C.

    2002-01-01

    Bacteriophage M13 is a virus that infects the bacteria Escherichia coli ( E. coli ), a single cell organism that resides in our intestines. It consists of the cytoplasm (contents) and a double membrane that keeps the

  15. Test module development to detect the flase call probe pins on microeprocessor test equipment

    Science.gov (United States)

    Tang, L. W.; Ong, N. R.; Mohamad, I. S. B.; Alcain, J. B.; Retnasamy, V.

    2017-09-01

    Probe pins are useful for electrical testing of microelectronic components, printed circuit board assembly (PCBA), microprocessors and other electronic devices due to it provides the conductivity test based on specific device circuit design. During the repeatable test runs, the load of test modules, contact failures and the current conductivity induces layer wear off all the tip of probe pins contact. Contamination will be build-up on probe pins and increased contact resistivity which results of cost loss and time loss for rectifying programs, rectifying testers and exchanging new probe pins. In this study, a resistivity approach will be developed to provide "Testing of Test Probes". The test module based on "Four-wire Ohm measurement" method with two alternative ways of applying power supply, that are 9V from a single power supply and 5V from Arduino UNO power supply were demonstrated to measure the small resistance value of microprocessor probe pin. A microcontroller with VEE Pro software was used to record the measurement data. The accuracy of both test modules were calibrated under different temperature conditions and result shows that 9V from a single power supply test module has higher measurement accuracy.

  16. Application of 13C and 15N stable isotope probing to characterize RDX degrading microbial communities under different electron-accepting conditions

    International Nuclear Information System (INIS)

    Cho, Kun-Ching; Lee, Do Gyun; Fuller, Mark E.; Hatzinger, Paul B.; Condee, Charles W.; Chu, Kung-Hui

    2015-01-01

    Highlights: • SIP characterized RDX-degrading communities under different e-accepting conditions. • Dominant RDX degradation pathways differed under different e-accepting conditions. • More complete detoxification of RDX occurred under methanogenic and sulfate-reducing conditions than under manganese(IV) and iron(III)-reducing conditions. - Abstract: This study identified microorganisms capable of using the explosive hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) or its metabolites as carbon and/or nitrogen sources under different electron-accepting conditions using 13 C and 15 N stable isotope probing (SIP). Mesocosms were constructed using groundwater and aquifer solids from an RDX-contaminated aquifer. The mesocosms received succinate as a carbon source and one of four electron acceptors (nitrate, manganese(IV), iron(III), or sulfate) or no additional electron acceptor (to stimulate methanogenesis). When RDX degradation was observed, subsamples from each mesocosm were removed and amended with 13 C 3 - or ring- 15 N 3 -, nitro- 15 N 3 -, or fully-labeled 15 N 6 -RDX, followed by additional incubation and isolation of labeled nucleic acids. A total of fifteen 16S rRNA sequences, clustering in α- and γ-Proteobacteria, Clostridia, and Actinobacteria, were detected in the 13 C-DNA fractions. A total of twenty seven sequences were derived from different 15 N-DNA fractions, with the sequences clustered in α- and γ-Proteobacteria, and Clostridia. Interestingly, sequences identified as Desulfosporosinus sp. (in the Clostridia) were not only observed to incorporate the labeled 13 C or 15 N from labeled RDX, but also were detected under each of the different electron-accepting conditions. The data suggest that 13 C- and 15 N-SIP can be used to characterize microbial communities involved in RDX biodegradation, and that the dominant pathway of RDX biodegradation may differ under different electron-accepting conditions

  17. High precision micro-scale Hall Effect characterization method using in-line micro four-point probes

    DEFF Research Database (Denmark)

    Petersen, Dirch Hjorth; Hansen, Ole; Lin, Rong

    2008-01-01

    Accurate characterization of ultra shallow junctions (USJ) is important in order to understand the principles of junction formation and to develop the appropriate implant and annealing technologies. We investigate the capabilities of a new micro-scale Hall effect measurement method where Hall...... effect is measured with collinear micro four-point probes (M4PP). We derive the sensitivity to electrode position errors and describe a position error suppression method to enable rapid reliable Hall effect measurements with just two measurement points. We show with both Monte Carlo simulations...... and experimental measurements, that the repeatability of a micro-scale Hall effect measurement is better than 1 %. We demonstrate the ability to spatially resolve Hall effect on micro-scale by characterization of an USJ with a single laser stripe anneal. The micro sheet resistance variations resulting from...

  18. Repeatability and reliability of muscle relaxation properties induced by motor cortical stimulation.

    Science.gov (United States)

    Molenaar, Joery P; Voermans, Nicol C; de Jong, Lysanne A; Stegeman, Dick F; Doorduin, Jonne; van Engelen, Baziel G

    2018-03-15

    Impaired muscle relaxation is a feature of many neuromuscular disorders. However, there are few tests available to quantify muscle relaxation. Transcranial magnetic stimulation (TMS) of the motor cortex can induce muscle relaxation by abruptly inhibiting corticospinal drive. The aim of our study is to investigate if repeatability and reliability of TMS-induced relaxation is greater than voluntary relaxation. Furthermore, effects of sex, cooling and fatigue on muscle relaxation properties were studied. Muscle relaxation of deep finger flexors was assessed in twenty-five healthy subjects (14 M and 11 F, aged 39.1{plus minus}12.7 and 45.3{plus minus}8.7 years old, respectively) using handgrip dynamometry. All outcome measures showed greater repeatability and reliability in TMS-induced relaxation compared to voluntary relaxation. The within-subject coefficient of variability of normalized peak relaxation rate was lower in TMS-induced relaxation than in voluntary relaxation (3.0 vs 19.7% in men, and 6.1 vs 14.3% in women). The repeatability coefficient was lower (1.3 vs 6.1 s -1 in men and 2.3 vs 3.1 s -1 in women), and the intraclass correlation coefficient was higher (0.95 vs 0.53 in men and 0.78 vs 0.69 in women), for TMS-induced relaxation compared to voluntary relaxation. TMS enabled to demonstrate slowing effects of sex, muscle cooling, and muscle fatigue on relaxation properties that voluntary relaxation could not. In conclusion, repeatability and reliability of TMS-induced muscle relaxation was greater compared to voluntary muscle relaxation. TMS-induced muscle relaxation has the potential to be used in clinical practice for diagnostic purposes and therapy effect monitoring in patients with impaired muscle relaxation.

  19. A novel dog-bone oscillating AFM probe with thermal actuation and piezoresistive detection.

    Science.gov (United States)

    Xiong, Zhuang; Mairiaux, Estelle; Walter, Benjamin; Faucher, Marc; Buchaillot, Lionel; Legrand, Bernard

    2014-10-31

    In order to effectively increase the resonance frequency and the quality factor of atomic force microscope (AFM) probes, a novel oscillating probe based on a dog-bone shaped MEMS resonator was conceived, designed, fabricated and evaluated. The novel probe with 400 μm in length, 100 μm in width and 5 μm in thickness was enabled to feature MHz resonance frequencies with integrated thermal actuation and piezoresistive detection. Standard silicon micromachining was employed. Both electrical and optical measurements were carried out in air. The resonance frequency and the quality factor of the novel probe were measured to be 5.4 MHz and 4000 respectively, which are much higher than those (about several hundreds of kHz) of commonly used cantilever probes. The probe was mounted onto a commercial AFM set-up through a dedicated probe-holder and circuit board. Topographic images of patterned resist samples were obtained. It is expected that the resonance frequency and the measurement bandwidth of such probes will be further increased by a proper downscaling, thus leading to a significant increase in the scanning speed capability of AFM instruments.

  20. Geothermal long-term modelling of a solar coupled geothermal probe heat storage in Crailsheim; Geothermische Langzeitmodellierung eines solargekoppelten Erdsonden-Waermespeichers in Crailsheim

    Energy Technology Data Exchange (ETDEWEB)

    Homuth, Sebastian; Mikisek, Philipp; Goetz, Annette E.; Sass, Ingo [Technische Univ. Darmstadt (Germany). Fachgebiet Angewandte Geothermie

    2011-10-24

    The thermal variations of the subsurface in the vicinity of a seasonal solar coupled geothermal probe heat storage were modeled using FEFLOW {sup registered} over a period of thirty years. The geothermal probe heat storage consists of eighty boreholes in an area of 85 square meters. The geothermal probes have a depth of 55 m and are mainly located in limestones of the Upper Muschelkalk (Triassic). The geothermal probe heat storage is thermally loaded from April to September. The thermal discharge takes place from October to March. The thermal and hydraulic input data of the model are based on three 80 meter deep geothermal probes (GWM 1-3) in the vicinity of the storage. The cores were completely lithologically, facially and finely stratigraphically affiliated. Measurements of thermal conductivity, permeability, porosity and density of 76 representative samples from the geothermal probe GWM 3 and measurements of the main fracture directions in two reference digestions at Crailsheim enabled a most realistic modeling of the storage. The results of the long-term modeling can be used for a detailed forecasting of the thermal alterations in the subsurface.

  1. Influence of access hole parameters on neutron moisture probe readings

    International Nuclear Information System (INIS)

    Abeele, W.V.

    1978-04-01

    Computing soil moisture content with a neutron probe requires use of a calibration curve that considers the thermal neutron capture cross section of the hole liner as well as the hole diameter. The influence of steel, polyvinyl chloride, and aluminum casings that fit 0.051 to 0.102-hole diameters was determined by comparison with neutron probe readings in uncased holes of corresponding diameters. Eccentricity of probe location was considered a potentially significant variable. The relationship between hole diameter and count rate also was investigated. The experiment was run in disturbed Bandelier tuff with an average dry density of 1.2 g . cm -3 and moisture content of 1.3 to 35.5% by volume. The casing material and hole diameter influenced the probe readings significantly, whereas eccentric location of the probe did not. Regression analyses showed an almost perfect inverse linear correlation between hole diameter and count rate

  2. TORE SUPRA fast reciprocating radio frequency probe

    International Nuclear Information System (INIS)

    Thomas, C.E. Jr.; Harris, J.H.; Haste, G.R.; Kwon, M.; Goulding, R.H.; Hoffman, D.J.; Saoutic, B.; Becoulet, A.; Fraboulet, D.; Beaumont, B.; Kuus, H.; Ladurelle, L.; Pascal, J.Y.

    1995-01-01

    A fast reciprocating ion cyclotron range of frequencies (ICRF) probe was installed and operated on TORE SUPRA during 1992/1993. The body of the probe was originally used on the ATF experiment at Oak Ridge National Laboratory. The probe was adapted for use on TORE SUPRA, and mounted on one of the two fast reciprocating probe mounts. The probe consists of two orthogonal single-turn wire loops, mounted so that one loop senses toroidal rf magnetic fields and the other senses poloidal rf magnetic fields. The probe began operation in June, 1993. The probe active area is approximately 5 cm long by 2 cm, and the reciprocating mount has a slow stroke (5 cm/s) of 30 cm and a fast stroke (1.5 m/s) of about 10 cm. The probe was operated at distances from the plasma edge ranging from 30 to -5 cm (i.e., inside the last closed flux surface). The probe design, electronics, calibration, data acquisition, and data processing are discussed. First data from the probe are presented as a function of ICRF power, distance from the plasma, loop orientation, and other plasma parameters. Initial data show parametric instabilities do not play an important role for ICRF in the TORE SUPRA edge and scrape-off-layer (SOL) plasmas. Additionally it is observed that the probe signal has little or no dependence on position in the SOL/plasma edge

  3. Nuclear critical opalescence and the M1 form factors of 12C and 13C

    International Nuclear Information System (INIS)

    Delorme, J.; Figureau, A.; Guichon, P.

    1981-01-01

    It is shown that core polarization by the nuclear pion field has opposite effects on the M1 form factors of 12 C(15.11 MeV) and 13 C(g.s.). New data on 13 C are found to agree with this prediction and a common interpretation of the experiments is shown to be possible for the two nuclei in terms of critical opalescence. Discrimination from alternative explanations of the observed anomalies should await further experiments, especially photopion reactions. (orig.)

  4. Isotropic Broadband E-Field Probe

    Directory of Open Access Journals (Sweden)

    Béla Szentpáli

    2008-01-01

    Full Text Available An E-field probe has been developed for EMC immunity tests performed in closed space. The leads are flexible resistive transmission lines. Their influence on the field distribution is negligible. The probe has an isotropic reception from 100 MHz to 18 GHz; the sensitivity is in the 3 V/m–10 V/m range. The device is an accessory of the EMC test chamber. The readout of the field magnitude is carried out by personal computer, which fulfils also the required corrections of the raw data.

  5. Two sugar-rhodamine "turn-on" fluorescent probes for the selective detection of Fe3 +

    Science.gov (United States)

    Chen, Qing; Fang, Zhijie

    2018-03-01

    Two new sugar-rhodamine fluorescent probes (RDG1 and RDG2) have been synthesized and characterized by 1H NMR, 13C NMR and HRMS. Their UV-Vis, fluorescence spectra and fluorescence-response to Fe3 + are investigated and discussed. RDG1 had a very nice linear relationship between UV absorbance and Fe3 + concentration with the correlation coefficient as high as 0.997 and the detection limit is 3.46 × 10- 6 M. Upon the addition of Fe3 +, the spirolactam ring of RDG1 was opened and a 1:1 metal ligand complex was formed from Job's plot. The results showed that RDG1 can be used as an effective fluorescent probe for selective detection of Fe3 + in water. RDG2 was incorporated the well-known rhodamine group and a water-soluble D-glucose group within one molecule and can be used for detecting Fe3 + in natural water as a selective fluorescent sensor. The addition of Fe3 + into RDG2 resulted in a strongly enhanced fluorescence as well as color change of solution from colorless to pink. Job's plot of RDG2 indicated 1:1 stoichiometry of RDG2-Fe3 +. RDG2 can serve as a probe for Fe3 + between pH = 4.0 to 7.0 and it's detection limit is 2.09 × 10- 6 M. The OFF-ON fluorescent mechanisms of RDG1-Fe3 + and RDG2-Fe3 + are proposed.

  6. Observation of the low frequency vibrational modes of bacteriophage M13 in water by Raman spectroscopy

    Directory of Open Access Journals (Sweden)

    Tsen Shaw-Wei D

    2006-09-01

    Full Text Available Abstract Background Recently, a technique which departs radically from conventional approaches has been proposed. This novel technique utilizes biological objects such as viruses as nano-templates for the fabrication of nanostructure elements. For example, rod-shaped viruses such as the M13 phage and tobacco mosaic virus have been successfully used as biological templates for the synthesis of semiconductor and metallic nanowires. Results and discussion Low wave number (≤ 20 cm-1 acoustic vibrations of the M13 phage have been studied using Raman spectroscopy. The experimental results are compared with theoretical calculations based on an elastic continuum model and appropriate Raman selection rules derived from a bond polarizability model. The observed Raman mode has been shown to belong to one of the Raman-active axial torsion modes of the M13 phage protein coat. Conclusion It is expected that the detection and characterization of this low frequency vibrational mode can be used for applications in nanotechnology such as for monitoring the process of virus functionalization and self-assembly. For example, the differences in Raman spectra can be used to monitor the coating of virus with some other materials and nano-assembly process, such as attaching a carbon nanotube or quantum dots.

  7. The radius of the quiescent neutron star in the globular cluster M13

    Science.gov (United States)

    Shaw, A. W.; Heinke, C. O.; Steiner, A. W.; Campana, S.; Cohn, H. N.; Ho, W. C. G.; Lugger, P. M.; Servillat, M.

    2018-06-01

    X-ray spectra of quiescent low-mass X-ray binaries containing neutron stars can be fit with atmosphere models to constrain the mass and the radius. Mass-radius constraints can be used to place limits on the equation of state of dense matter. We perform fits to the X-ray spectrum of a quiescent neutron star in the globular cluster M13, utilizing data from ROSAT, Chandra, and XMM-Newton, and constrain the mass-radius relation. Assuming an atmosphere composed of hydrogen and a 1.4 M⊙ neutron star, we find the radius to be R_NS=12.2^{+1.5}_{-1.1} km, a significant improvement in precision over previous measurements. Incorporating an uncertainty on the distance to M13 relaxes the radius constraints slightly and we find R_NS=12.3^{+1.9}_{-1.7} km (for a 1.4M⊙ neutron star with a hydrogen atmosphere), which is still an improvement in precision over previous measurements, some of which do not consider distance uncertainty. We also discuss how the composition of the atmosphere affects the derived radius, finding that a helium atmosphere implies a significantly larger radius.

  8. 33S NMR cryogenic probe for taurine detection

    Science.gov (United States)

    Hobo, Fumio; Takahashi, Masato; Maeda, Hideaki

    2009-03-01

    With the goal of a S33 nuclear magnetic resonance (NMR) probe applicable to in vivo NMR on taurine-biological samples, we have developed the S33 NMR cryogenic probe, which is applicable to taurine solutions. The NMR sensitivity gain relative to a conventional broadband probe is as large as 3.5. This work suggests that improvements in the preamplifier could allow NMR measurements on 100 μM taurine solutions, which is the level of sensitivity necessary for biological samples.

  9. Study of charge reader probes for electret dosemeters; Estudo de sondas leitoras de carga para dosimetros de eletretos

    Energy Technology Data Exchange (ETDEWEB)

    Parada, Marco A.; Silva, Nivaldo C. da; Almeida, Adelaide de [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica

    2001-07-01

    Electrets are insulating materials with a quasi-permanent polarization. It can be made from carnauba wax, Teflon and other materials for several applications as transducers, electrophotography, high efficiency air filters and as radiation dosimeters. Electret dosemeters may be used for {alpha}, {beta}, {gamma}, X, e{sup -} and neutrons radiations with a low construction cost and a simple associated instrumentation. The probe, for charge measurements of the electret dosimeters, is an important device in the experimental set up and its geometry varies according to the geometry of the dosimeter or the scope of the measurements. In this work the development of several probes is described (cylindrical, 1/3 cylindrical and three points probes with different sizes). From the measurements one can demonstrate that cylindrical probe may be used for cylindrical electret geometry, 1/3 cylindrical probe for measurements of directional dependence of the dose and point probe for scanning measurements of plane areas. For high resolution, small point probe may be used and for high sensitivity, the probe-electret distance must be minimized taking account of the Paschen discharge. (author)

  10. Sensitivity studies on the multi-sensor conductivity probe measurement technique for two-phase flows

    Energy Technology Data Exchange (ETDEWEB)

    Worosz, Ted [Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, 230 Reber Building, University Park, PA 16802 (United States); Bernard, Matt [The United States Nuclear Regulatory Commission, 11545 Rockville Pike, Rockville, MD 20852 (United States); Kong, Ran; Toptan, Aysenur [Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, 230 Reber Building, University Park, PA 16802 (United States); Kim, Seungjin, E-mail: skim@psu.edu [Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, 230 Reber Building, University Park, PA 16802 (United States); Hoxie, Chris [The United States Nuclear Regulatory Commission, 11545 Rockville Pike, Rockville, MD 20852 (United States)

    2016-12-15

    Highlights: • Revised conductivity probe circuit to eliminate signal “ghosting” among sensors. • Higher sampling frequencies suggested for bubble number frequency and a{sub i} measurements. • Two-phase parameter sensitivity to measurement duration and bubble number investigated. • Sensors parallel to pipe wall recommended for symmetric bubble velocity measurements. • Sensor separation distance ratio (s/d) greater than four minimizes bubble velocity error. - Abstract: The objective of this study is to advance the local multi-sensor conductivity probe measurement technique through systematic investigation into several practical aspects of a conductivity probe measurement system. Firstly, signal “ghosting” among probe sensors is found to cause artificially high bubble velocity measurements and low interfacial area concentration (a{sub i}) measurements that depend on sampling frequency and sensor impedance. A revised electrical circuit is suggested to eliminate this artificial variability. Secondly, the sensitivity of the probe measurements to sampling frequency is investigated in 13 two-phase flow conditions with superficial liquid and gas velocities ranging from 1.00–5.00 m/s and 0.17–2.0 m/s, respectively. With increasing gas flow rate, higher sampling frequencies, greater than 100 kHz in some cases, are required to adequately capture the bubble number frequency and a{sub i} measurements. This trend is due to the increase in gas velocity and the transition to the slug flow regime. Thirdly, the sensitivity of the probe measurements to the measurement duration as well as the sample number is investigated for the same flow conditions. Measurements of both group-I (spherical/distorted) and group-II (cap/slug/churn-turbulent) bubbles are found to be relatively insensitive to both the measurement duration and the number of bubbles, as long as the measurements are made for a duration long enough to capture a collection of samples characteristic to a

  11. Thermal probe design for Europa sample acquisition

    Science.gov (United States)

    Horne, Mera F.

    2018-01-01

    The planned lander missions to the surface of Europa will access samples from the subsurface of the ice in a search for signs of life. A small thermal drill (probe) is proposed to meet the sample requirement of the Science Definition Team's (SDT) report for the Europa mission. The probe is 2 cm in diameter and 16 cm in length and is designed to access the subsurface to 10 cm deep and to collect five ice samples of 7 cm3 each, approximately. The energy required to penetrate the top 10 cm of ice in a vacuum is 26 Wh, approximately, and to melt 7 cm3 of ice is 1.2 Wh, approximately. The requirement stated in the SDT report of collecting samples from five different sites can be accommodated with repeated use of the same thermal drill. For smaller sample sizes, a smaller probe of 1.0 cm in diameter with the same length of 16 cm could be utilized that would require approximately 6.4 Wh to penetrate the top 10 cm of ice, and 0.02 Wh to collect 0.1 g of sample. The thermal drill has the advantage of simplicity of design and operations and the ability to penetrate ice over a range of densities and hardness while maintaining sample integrity.

  12. An inverted repeat motif stabilizes binding of E2F and enhances transcription of the dihydrofolate reductase gene

    DEFF Research Database (Denmark)

    Wade, M; Blake, M C; Jambou, R C

    1995-01-01

    consensus E2F site, significantly decrease the binding stability of all of the forms of E2F tested. The rate of association of E2F-1/DP-1 heterodimers with the inverted repeat wild type site was not significantly different from those with the two single site mutated probes. Furthermore, the mutations...

  13. Whole-cell hybridization of Methanosarcina cells with two new oligonucleotide probes

    DEFF Research Database (Denmark)

    Sørensen, A.H.; Torsvik, V.L.; Torsvik, T.

    1997-01-01

    Two new oligonucleotide probes targeting the 16S rRNA of the methanogenic genus Methanosarcina were developed. The probes have the following sequences (Escherichia coli numbering): probe SARCI551, 5'-GAC CCAATAATCACGATCAC-3', and probe SARCI645, 5'-TCCCGGTTCCAAGTCTGGC-3'. In situ hybridization...... with the fluorescently labelled probes required several modifications of standard procedures. Cells of Methanosarcina mazeii S-6 were found to lyse during the hybridization step if fixed in 3% formaldehyde and stored in 50% ethanol. Lysis was, however, not observed with cells fixed and stored in 1.6% formaldehyde-0.......85% NaCl. Extensive autofluorescence of the cells was found upon hybridization in the presence of 5 mM EDTA, but successful hybridization could be obtained without addition of this compound. The mounting agent Citifluor AF1, often used in conjugation with the fluorochrome fluorescein, was found to wash...

  14. Structural elucidation of the Brucella melitensis M antigen by high-resolution NMR at 500 MHz

    International Nuclear Information System (INIS)

    Bundle, D.R.; Cherwonogrodzky, J.W.; Perry, M.B.

    1987-01-01

    The Brucella M antigen from the species type strain Brucella melitensis 16M has been identified as a component of the cell wall lipopolysaccharide (LPS). O polysaccharide liberated from this LPS by mild acid hydrolysis exhibited M activity in serological tests and was shown to be a homopolymer of 4-formamido-4,6-dideoxy-α-D-mannopyranosyl residues arranged in an oligosaccharide repeating unit as judged by sodium dodecyl sulfate-polyacrylamide gel electrophoresis of the native lipopolysaccharide. Structural analysis of the O polysaccharide by NMR methods was difficult due to apparent microheterogeneity of the repeating unit, which was in fact caused by the presence of rotational isomers of the N-formyl moiety. This problem was resolved by chemical modification of the polysaccharide to its amino and N-acetyl derivatives, the 500-MHz 1 H and 125-MHz 13 C NMR spectra of which could be analyzed in terms of a unique structure through application of pH-dependent β-shifts and two-dimensional techniques that included COSY, relayed COSY, and NOESY experiments together with heteronuclear C/H shift correlation spectroscopy. On the basis of these experiments and supported by methylation and periodate oxidation data, the structure of the M polysaccharide was determined as a linear polymer of unbranched pentasaccharide repeating units consisting of four 1,2-linked and one 1,3-lined 4,6-dideoxy-4-formamido-α-D-mannopyranosyl residues. The marked structural similarity of the M antigen and the A antigen, which is known to be a 1,2-linked homopolysaccharide of 4,6-dideoxy-4-formamido-α-D-mannopyranosyl units, accounts for cross-serological reactions of the two and the long-standing confusion surrounding the nature of their antigenic determinants

  15. Curve-of-growth analysis of a red giant in the globular cluster M13

    International Nuclear Information System (INIS)

    Griffin, R.

    1979-01-01

    A coude spectrogram of a red giant (L973) in the globular cluster M13 is analysed, with respect to α Boo, by the differential curve-of-growth technique. The overall metal abundance is found to be approximately one-tenth of that of α Boo, or one-fortieth that of the Sun. (author)

  16. The TORE SUPRA fast reciprocating RF probe

    International Nuclear Information System (INIS)

    Thomas, C.E. Jr.; Harris, J.H.; Haste, G.R.

    1994-01-01

    A fast reciprocating ICRF (Ion Cyclotron Range of Frequencies) probe was installed and operated on TORE SUPRA during 1992/1993. The body of the probe was originally used on the ATF experiment at ORNL. The probe was adapted for use on TORE SUPRA, and mounted on one of the two fast reciprocating probe mounts. The probe consists of two orthogonal single-turn wire loops, mounted so that one loop senses toroidal RF magnetic fields and the other senses poloidal RF magnetic fields. The probe began operation in June, 1993. The probe active area is approximately 5 cm long by 2 cm, and the reciprocating mount has a slow stroke (5 cm/sec) of 30 cm by 2 cm, and the reciprocating mount has a slow stroke (5 cm/sec) of 30 cm and a fast stroke (1.5 m/sec) of about 10 cm. The probe was operated at distances from the plasma edge ranging from 30 cm to -5 cm (i.e., inside the last closed flux surface). The probe design, electronics, calibration, data acquisition and data processing are discussed. First data from the probe are presented as a function of ICRF power, distance from the plasma, loop orientation, and other plasma parameters. Initial data shows parametric instabilities do not play an important role for ICRF in the TORE SUPRA edge and scrape-off-layer (SOL) plasmas. Additionally it is observed that the probe signal has little or no dependence on position in the SOL/plasma edge

  17. Mobile Probing and Probes

    DEFF Research Database (Denmark)

    Duvaa, Uffe; Ørngreen, Rikke; Weinkouff Mathiasen, Anne-Gitte

    2013-01-01

    Mobile probing is a method, developed for learning about digital work situations, as an approach to discover new grounds. The method can be used when there is a need to know more about users and their work with certain tasks, but where users at the same time are distributed (in time and space......). Mobile probing was inspired by the cultural probe method, and was influenced by qualitative interview and inquiry approaches. The method has been used in two subsequent projects, involving school children (young adults at 15-17 years old) and employees (adults) in a consultancy company. Findings point...... to mobile probing being a flexible method for uncovering the unknowns, as a way of getting rich data to the analysis and design phases. On the other hand it is difficult to engage users to give in depth explanations, which seem easier in synchronous dialogs (whether online or face2face). The development...

  18. Mobile Probing and Probes

    DEFF Research Database (Denmark)

    Duvaa, Uffe; Ørngreen, Rikke; Weinkouff, Anne-Gitte

    2012-01-01

    Mobile probing is a method, which has been developed for learning about digital work situations, as an approach to discover new grounds. The method can be used when there is a need to know more about users and their work with certain tasks, but where users at the same time are distributed (in time...... and space). Mobile probing was inspired by the cultural probe method, and was influenced by qualitative interview and inquiry approaches. The method has been used in two subsequent projects, involving school children (young adults at 15-17 years old) and employees (adults) in a consultancy company. Findings...... point to mobile probing being a flexible method for uncovering the unknowns, as a way of getting rich data to the analysis and design phases. On the other hand it is difficult to engage users to give in depth explanations, which seem easier in synchronous dialogs (whether online or face2face...

  19. Poor methodological detail precludes experimental repeatability and hampers synthesis in ecology.

    Science.gov (United States)

    Haddaway, Neal R; Verhoeven, Jos T A

    2015-10-01

    Despite the scientific method's central tenets of reproducibility (the ability to obtain similar results when repeated) and repeatability (the ability to replicate an experiment based on methods described), published ecological research continues to fail to provide sufficient methodological detail to allow either repeatability of verification. Recent systematic reviews highlight the problem, with one example demonstrating that an average of 13% of studies per year (±8.0 [SD]) failed to report sample sizes. The problem affects the ability to verify the accuracy of any analysis, to repeat methods used, and to assimilate the study findings into powerful and useful meta-analyses. The problem is common in a variety of ecological topics examined to date, and despite previous calls for improved reporting and metadata archiving, which could indirectly alleviate the problem, there is no indication of an improvement in reporting standards over time. Here, we call on authors, editors, and peer reviewers to consider repeatability as a top priority when evaluating research manuscripts, bearing in mind that legacy and integration into the evidence base can drastically improve the impact of individual research reports.

  20. Inter- and intra-strain variability of tandem repeats in Mycoplasma pneumoniae based on next-generation sequencing data.

    Science.gov (United States)

    Zhang, Jing; Song, Xiaohong; Ma, Marella J; Xiao, Li; Kenri, Tsuyoshi; Sun, Hongmei; Ptacek, Travis; Li, Shaoli; Waites, Ken B; Atkinson, T Prescott; Shibayama, Keigo; Dybvig, Kevin; Feng, Yanmei

    2017-02-01

    To characterize inter- and intra-strain variability of variable-number tandem repeats (VNTRs) in Mycoplasma pneumoniae to determine the optimal multilocus VNTR analysis scheme for improved strain typing. Whole genome assemblies and next-generation sequencing data from diverse M. pneumoniae isolates were used to characterize VNTRs and their variability, and to compare the strain discriminability of new VNTR and existing markers. We identified 13 VNTRs including five reported previously. These VNTRs displayed different levels of inter- and intra-strain copy number variations. All new markers showed similar or higher discriminability compared with existing VNTR markers and the P1 typing system. Our study provides novel insights into VNTR variations and potential new multilocus VNTR analysis schemes for improved genotyping of M. pneumoniae.

  1. Syntenic homology of human unique DNA sequences within chromossome regions 5q31, 10q22, 13q32-33 and 19q13.1 in the great apes

    Directory of Open Access Journals (Sweden)

    Rhea U. Vallente-Samonte

    2000-09-01

    Full Text Available Homologies between chromosome banding patterns and DNA sequences in the great apes and humans suggest an apparent common origin for these two lineages. The availability of DNA probes for specific regions of human chromosomes (5q31, 10q22, 13q32-33 and 19q13.1 led us to cross-hybridize these to chimpanzee (Pan troglodytes, PTR, gorilla (Gorilla gorilla, GGO and orangutan (Pongo pygmaeus, PPY chromosomes in a search for equivalent regions in the great apes. Positive hybridization signals to the chromosome 5q31-specific DNA probe were observed at HSA 5q31, PTR 4q31, GGO 4q31 and PPY 4q31, while fluorescent signals using the chromosome 10q22-specific DNA probe were noted at HSA 10q22, PTR 8q22, GGO 8q22 and PPY 7q22. The chromosome arms showing hybridization signals to the Quint-EssentialTM 13-specific DNA probe were identified as HSA 13q32-33, PTR 14q32-33, GGO 14q32-33 and PPY 14q32-33, while those presenting hybridization signals to the chromosome 19q13.1-specific DNA probe were identified as HSA 19q13.1, PTR 20q13, GGO 20q13 and PPY 20q13. All four probes presumably hybridized to homologous chromosomal locations in the apes, which suggests a homology of certain unique DNA sequences among hominoid species.Homologias entre os padrões de bandamento de cromossomos e seqüências de DNA em grandes macacos e humanos sugerem uma aparente origem comum para estas duas linhagens. A disponibilidade de sondas de DNA para regiões específicas de cromossomos humanos (5q31, 10q22, 13q32-33 e 19q13.1 nos levou a realizar hibridação cruzada com cromossomos de chimpanzé (Pan troglodytes, PTR, gorila (Gorilla gorilla, GGO e orangotango (Pongo pygmaeus, PPY em um pesquisa de regiões equivalentes em grandes macacos. Sinais positivos de hibridação para a sonda de DNA específica para o cromossomo 5q31 foram observados em HSA 5q31, PTR 4q31, GGO 4q31 e PPY 4q31, enquanto que sinais fluorescentes usando a sonda de DNA específica para o cromossomo 10q22 foram

  2. Preparation of 99Tcm-CLP imaging probe of lung carcinoma

    International Nuclear Information System (INIS)

    Qiang Yonggang; Liao Yonghua

    2004-01-01

    The process of preparing an imaging micro-probe 99 Tc m -CLP from bovine nose cartilage is described in detail. Both labeled rate and radiochemical purity of 99 Tc m -CLP are greater than 90%, and KA is 1.12 x 10 9 L/mol in vitro. After the Balb/c nu/nu mice with lung cancer were intravenously injected by the 99 Tc m -CLP, the radioactivity was found to be well concentrated at the lung-cancer region, which suggests that the 99 Tc m -CLP micro-probe can be used in imaging study of lung carcinoma. (authors)

  3. A Novel Dog-Bone Oscillating AFM Probe with Thermal Actuation and Piezoresistive Detection †

    Science.gov (United States)

    Xiong, Zhuang; Mairiaux, Estelle; Walter, Benjamin; Faucher, Marc; Buchaillot, Lionel; Legrand, Bernard

    2014-01-01

    In order to effectively increase the resonance frequency and the quality factor of atomic force microscope (AFM) probes, a novel oscillating probe based on a dog-bone shaped MEMS resonator was conceived, designed, fabricated and evaluated. The novel probe with 400 μm in length, 100 μm in width and 5 μm in thickness was enabled to feature MHz resonance frequencies with integrated thermal actuation and piezoresistive detection. Standard silicon micromachining was employed. Both electrical and optical measurements were carried out in air. The resonance frequency and the quality factor of the novel probe were measured to be 5.4 MHz and 4000 respectively, which are much higher than those (about several hundreds of kHz) of commonly used cantilever probes. The probe was mounted onto a commercial AFM set-up through a dedicated probe-holder and circuit board. Topographic images of patterned resist samples were obtained. It is expected that the resonance frequency and the measurement bandwidth of such probes will be further increased by a proper downscaling, thus leading to a significant increase in the scanning speed capability of AFM instruments. PMID:25365463

  4. Carbohydrate mouth rinse does not improve repeated sprint performance

    Directory of Open Access Journals (Sweden)

    Leandro Ricardo Altimari

    2013-09-01

    Full Text Available The objective of this study was to evaluate the effect of a carbohydrate mouth rinse on the repeated sprint ability (RSA of young soccer players. Nine youth soccer players (15.0 ± 1.5 years; 60.7 ± 4.84 kg; 1.72 ± 0.05 m; 20.5 ± 1.25 kg/m2 were selected. The athletes were submitted to an RSA test consisting of six sprints of 40 m (going/return = 20 m + 20 m, separated by 20 s of passive recovery, under three experimental conditions: carbohydrate mouth rinse (CHO or placebo (PLA and control (CON. The mouth rinses containing CHO or PLA were administered 5 min and immediately before the beginning of the test in doses of 100 mL. The best sprint time (RSAbest, mean sprint time (RSAmean, and drop-off in sprint performance (fatigue index were determined for the different treatments. One-not identify significant differences (p> 0.05 in RSAbest (CHO way ANOVA for repeated measures did = 7.30 ± 0.31 s; PLA = 7.30 ± 0.30 s; CON = 7.26 ±0.16 s, RSA mean (CHO = 7.71 ± 0.30 s; PLA = 7.71 ± 0.25 s; CON = 7.66 ± 0.24s, or fatigue index (CHO = 5.58 ± 2.16%; PLA = 5.77 ± 3.04%; CON = 5.55 ±3.72%. The results suggest that a carbohydrate mouth rinse does not improve the repeated sprint performance of young soccer players.

  5. Preclinical evaluation of a new, stabilized neurotensin(8--13) pseudopeptide radiolabeled with (99m)tc.

    Science.gov (United States)

    García-Garayoa, Elisa; Bläuenstein, Peter; Bruehlmeier, Matthias; Blanc, Alain; Iterbeke, Koen; Conrath, Peter; Tourwé, Dirk; Schubiger, P August

    2002-03-01

    The rapid degradation of neurotensin (NT) limits its clinical use in cancer imaging and therapy. Thus, a new NT(8--13) pseudopeptide, NT-VIII, was synthesized. Some changes were introduced in the sequence of NT(8--13) to stabilize the molecule against enzymatic degradation: Arg(8) was N-methylated, and Lys and Tle replaced Arg(9) and Ile(12), respectively. Finally, (NalphaHis)Ac was coupled to the N-terminus for (99m)Tc(CO)(3) labeling. This peptide was characterized both in vitro and in vivo. The new analog was labeled with (99m)Tc(CO)(3). Its metabolic stability was analyzed both in human plasma and in HT-29 cells. Binding properties, receptor downregulation, and internalization were tested with HT-29 cells. Biodistribution was evaluated in nude mice with HT-29 xenografts. (99m)Tc(CO)(3)NT-VIII showed a high stability in plasma, where most of the peptide remained intact after 24 h of incubation at 37 degreesC. However, the degradation in HT-29 cells was more rapid (46% of intact (99m)Tc(CO)(3)NT-VIII after 24 h at 37 degreesC). Binding to NT1 receptors (NTR1) was saturable and specific. Scatchard analysis showed a high affinity for (99m)Tc(CO)(3)NT-VIII, with a dissociation constant similar to (125)I-NT (1.8 vs. 1.6 nmol/L). After interacting with NTR1, (99m)Tc(CO)(3)NT-VIII was rapidly internalized, with more than 90% internalized after 30 min. It also distributed and cleared rapidly in nude mice bearing HT-29 xenografts. The highest rates of accumulation were found in kidney and tumor at all time points tested. Tumor uptake was highly specific because it could be blocked by coinjection with a high dose of (NalphaHis)Ac-NT(8--13). Tumors were clearly visualized in scintigraphy images. The changes that were introduced stabilized the molecule against enzymatic degradation without affecting binding properties. Moreover, the increase in stability enhanced tumor uptake, making this derivative a promising candidate for clinical use.

  6. Irradiation probe and laboratory for irradiated material evaluation

    International Nuclear Information System (INIS)

    Smutny, S.; Kupca, L.; Beno, P.; Stubna, M.; Mrva, V.; Chmelo, P.

    1975-09-01

    The survey and assessment are given of the tasks carried out in the years 1971 to 1975 within the development of methods for structural materials irradiation and of a probe for the irradiation thereof in the A-1 reactor. The programme and implementation of laboratory tests of the irradiation probe are described. In the actual reactor irradiation, the pulse tube length between the pressure governor and the irradiation probe is approximately 20 m, the diameter is 2.2 mm. Temperature reaches 800 degC while the pressure control system operates at 20 degC. The laboratory tests (carried out at 20 degC) showed that the response time of the pressure control system to a stepwise pressure change in the irradiation probe from 0 to 22 at. is 0.5 s. Pressure changes were also studied in the irradiation probe and in the entire system resulting from temperature changes in the irradiation probe. Temperature distribution in the body of the irradiation probe heating furnace was determined. (B.S.)

  7. Probe Selection for DNA Microarrays using OligoWiz

    DEFF Research Database (Denmark)

    Wernersson, Rasmus; Juncker, Agnieszka; Nielsen, Henrik Bjørn

    2007-01-01

    Nucleotide abundance measurements using DNA microarray technology are possible only if appropriate probes complementary to the target nucleotides can be identified. Here we present a protocol for selecting DNA probes for microarrays using the OligoWiz application. OligoWiz is a client-server appl......Nucleotide abundance measurements using DNA microarray technology are possible only if appropriate probes complementary to the target nucleotides can be identified. Here we present a protocol for selecting DNA probes for microarrays using the OligoWiz application. OligoWiz is a client......-server application that offers a detailed graphical interface and real-time user interaction on the client side, and massive computer power and a large collection of species databases (400, summer 2007) on the server side. Probes are selected according to five weighted scores: cross-hybridization, deltaT(m), folding...... computer skills and can be executed from any Internet-connected computer. The probe selection procedure for a standard microarray design targeting all yeast transcripts can be completed in 1 h....

  8. An indentation depth-force sensing wheeled probe for abnormality identification during minimally invasive surgery.

    Science.gov (United States)

    Liu, H; Puangmali, P; Zbyszewski, D; Elhage, O; Dasgupta, P; Dai, J S; Seneviratne, L; Althoefer, K

    2010-01-01

    This paper presents a novel wheeled probe for the purpose of aiding a surgeon in soft tissue abnormality identification during minimally invasive surgery (MIS), compensating the loss of haptic feedback commonly associated with MIS. Initially, a prototype for validating the concept was developed. The wheeled probe consists of an indentation depth sensor employing an optic fibre sensing scheme and a force/torque sensor. The two sensors work in unison, allowing the wheeled probe to measure the tool-tissue interaction force and the rolling indentation depth concurrently. The indentation depth sensor was developed and initially tested on a homogenous silicone phantom representing a good model for a soft tissue organ; the results show that the sensor can accurately measure the indentation depths occurring while performing rolling indentation, and has good repeatability. To validate the ability of the wheeled probe to identify abnormalities located in the tissue, the device was tested on a silicone phantom containing embedded hard nodules. The experimental data demonstrate that recording the tissue reaction force as well as rolling indentation depth signals during rolling indentation, the wheeled probe can rapidly identify the distribution of tissue stiffness and cause the embedded hard nodules to be accurately located.

  9. Fundamental size limitations of micro four-point probes

    DEFF Research Database (Denmark)

    Ansbæk, Thor; Petersen, Dirch Hjorth; Hansen, Ole

    2009-01-01

    The continued down-scaling of integrated circuits and magnetic tunnel junctions (MTJ) for hard disc read heads presents a challenge to current metrology technology. The four-point probes (4PP), currently used for sheet resistance characterization in these applications, therefore must be down......-scaled as well in order to correctly characterize the extremely thin films used. This presents a four-point probe design and fabrication challenge. We analyze the fundamental limitation on down-scaling of a generic micro four-point probe (M4PP) in a comprehensive study, where mechanical, thermal, and electrical...

  10. Recombination-dependent replication and gene conversion homogenize repeat sequences and diversify plastid genome structure.

    Science.gov (United States)

    Ruhlman, Tracey A; Zhang, Jin; Blazier, John C; Sabir, Jamal S M; Jansen, Robert K

    2017-04-01

    There is a misinterpretation in the literature regarding the variable orientation of the small single copy region of plastid genomes (plastomes). The common phenomenon of small and large single copy inversion, hypothesized to occur through intramolecular recombination between inverted repeats (IR) in a circular, single unit-genome, in fact, more likely occurs through recombination-dependent replication (RDR) of linear plastome templates. If RDR can be primed through both intra- and intermolecular recombination, then this mechanism could not only create inversion isomers of so-called single copy regions, but also an array of alternative sequence arrangements. We used Illumina paired-end and PacBio single-molecule real-time (SMRT) sequences to characterize repeat structure in the plastome of Monsonia emarginata (Geraniaceae). We used OrgConv and inspected nucleotide alignments to infer ancestral nucleotides and identify gene conversion among repeats and mapped long (>1 kb) SMRT reads against the unit-genome assembly to identify alternative sequence arrangements. Although M. emarginata lacks the canonical IR, we found that large repeats (>1 kilobase; kb) represent ∼22% of the plastome nucleotide content. Among the largest repeats (>2 kb), we identified GC-biased gene conversion and mapping filtered, long SMRT reads to the M. emarginata unit-genome assembly revealed alternative, substoichiometric sequence arrangements. We offer a model based on RDR and gene conversion between long repeated sequences in the M. emarginata plastome and provide support that both intra-and intermolecular recombination between large repeats, particularly in repeat-rich plastomes, varies unit-genome structure while homogenizing the nucleotide sequence of repeats. © 2017 Botanical Society of America.

  11. Continuously tunable nucleic acid hybridization probes.

    Science.gov (United States)

    Wu, Lucia R; Wang, Juexiao Sherry; Fang, John Z; Evans, Emily R; Pinto, Alessandro; Pekker, Irena; Boykin, Richard; Ngouenet, Celine; Webster, Philippa J; Beechem, Joseph; Zhang, David Yu

    2015-12-01

    In silico-designed nucleic acid probes and primers often do not achieve favorable specificity and sensitivity tradeoffs on the first try, and iterative empirical sequence-based optimization is needed, particularly in multiplexed assays. We present a novel, on-the-fly method of tuning probe affinity and selectivity by adjusting the stoichiometry of auxiliary species, which allows for independent and decoupled adjustment of the hybridization yield for different probes in multiplexed assays. Using this method, we achieved near-continuous tuning of probe effective free energy. To demonstrate our approach, we enforced uniform capture efficiency of 31 DNA molecules (GC content, 0-100%), maximized the signal difference for 11 pairs of single-nucleotide variants and performed tunable hybrid capture of mRNA from total RNA. Using the Nanostring nCounter platform, we applied stoichiometric tuning to simultaneously adjust yields for a 24-plex assay, and we show multiplexed quantitation of RNA sequences and variants from formalin-fixed, paraffin-embedded samples.

  12. Dependence of M13 Major Coat Protein Oligomerization and Lateral Segregation of Bilayer Composition

    NARCIS (Netherlands)

    Fernandes, F.; Loura, L.M.S.; Prieto, M.; Koehorst, R.B.M.; Spruijt, R.B.; Hemminga, M.A.

    2003-01-01

    M13 major coat protein was derivatized with BODIPY (n-(4,4-difluoro-5,7-dimethyl-4-bora-3a,4a-diaza-s-indacene-3-yl)methyl iodoacetamide), and its aggregation was studied in 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) and DOPC/1,2-dioleoyl-sn-glycero-3-[phospho-rac-(1-glycerol)] (DOPG) or

  13. The Making of the 1:3M Geological Map Series of Mercury: Status and Updates

    Science.gov (United States)

    Galluzzi, V.; Guzzetta, L.; Mancinelli, P.; Giacomini, L.; Lewang, A. M.; Malliband, C.; Mosca, A.; Pegg, D.; Wright, J.; Ferranti, L.; Hiesinger, H.; Massironi, M.; Pauselli, C.; Rothery, D. A.; Palumbo, P.

    2018-05-01

    A complete global series of 1:3M-scale maps of Mercury is being prepared in support to the ESA/JAXA BepiColombo mission. Currently, 35% of Mercury has been mapped and 55% of the planet will be covered soon by the maps in progress.

  14. An easily Prepared Fluorescent pH Probe Based on Dansyl.

    Science.gov (United States)

    Sha, Chunming; Chen, Yuhua; Chen, Yufen; Xu, Dongmei

    2016-09-01

    A novel fluorescent pH probe from dansyl chloride and thiosemicarbazide was easily prepared and fully characterized by (1)H NMR, (13)C NMR, LC-MS, Infrared spectra and elemental analysis. The probe exhibited high selectivity and sensitivity to H(+) with a pK a value of 4.98. The fluorescence intensity at 510 nm quenched 99.5 % when the pH dropped from 10.88 to 1.98. In addition, the dansyl-based probe could respond quickly and reversibly to the pH variation and various common metal ions showed negligible interference. The recognition could be ascribed to the intramolecular charge transfer caused by the protonation of the nitrogen in the dimethylamino group.

  15. Biosynthesis of highly enriched 13C-lycopene for human metabolic studies using repeated batch tomato cell culturing with 13C-glucose

    Science.gov (United States)

    Moran, Nancy E.; Rogers, Randy B.; Lu, Chi-Hua; Conlon, Lauren E.; Lila, Mary Ann; Clinton, Steven K.; Erdman, John W.

    2013-01-01

    While putative disease-preventing lycopene metabolites are found in both tomato (Solanum lycopersicum) products and in their consumers, mammalian lycopene metabolism is poorly understood. Advances in tomato cell culturing techniques offer an economical tool for generation of highly-enriched 13C-lycopene for human bioavailability and metabolism studies. To enhance the 13C-enrichment and yields of labeled lycopene from the hp-1 tomato cell line, cultures were first grown in 13C-glucose media for three serial batches and produced increasing proportions of uniformly labeled lycopene (14.3 +/− 1.2 %, 39.6 +/− 0.5 %, and 48.9 +/− 1.5% with consistent yields (from 5.8 to 9 mg/L). An optimized 9-day-long 13C-loading and 18-day-long labeling strategy developed based on glucose utilization and lycopene yields, yielded 13C-lycopene with 93% 13C isotopic purity, and 55% of isotopomers were uniformly labeled. Furthermore, an optimized acetone and hexane extraction led to a four-fold increase in lycopene recovery from cultures compared to a standard extraction. PMID:23561155

  16. Structure and Dynamics of the Globular Cluster Palomar 13

    Science.gov (United States)

    Bradford, J. D.; Geha, M.; Muñoz, R. R.; Santana, F. A.; Simon, J. D.; Côté, P.; Stetson, P. B.; Kirby, E.; Djorgovski, S. G.

    2011-12-01

    We present Keck/DEIMOS spectroscopy and Canada-France-Hawaii Telescope/MegaCam photometry for the Milky Way globular cluster Palomar 13. We triple the number of spectroscopically confirmed members, including many repeat velocity measurements. Palomar 13 is the only known globular cluster with possible evidence for dark matter, based on a Keck/High Resolution Echelle Spectrometer 21 star velocity dispersion of σ = 2.2 ± 0.4 km s-1. We reproduce this measurement, but demonstrate that it is inflated by unresolved binary stars. For our sample of 61 stars, the velocity dispersion is σ = 0.7+0.6 -0.5 km s-1. Combining our DEIMOS data with literature values, our final velocity dispersion is σ = 0.4+0.4 -0.3 km s-1. We determine a spectroscopic metallicity of [Fe/H] = -1.6 ± 0.1 dex, placing a 1σ upper limit of σ[Fe/H] ~ 0.2 dex on any internal metallicity spread. We determine Palomar 13's total luminosity to be MV = -2.8 ± 0.4, making it among the least luminous known globular clusters. The photometric isophotes are regular out to the half-light radius and mildly irregular outside this radius. The outer surface brightness profile slope is shallower than typical globular clusters (Σvpropr η, η = -2.8 ± 0.3). Thus at large radius, tidal debris is likely affecting the appearance of Palomar 13. Combining our luminosity with the intrinsic velocity dispersion, we find a dynamical mass of M 1/2 = 1.3+2: 7 -1.3 × 103 M ⊙ and a mass-to-light ratio of M/LV = 2.4+5.0 -2.4 M ⊙/L ⊙. Within our measurement errors, the mass-to-light ratio agrees with the theoretical predictions for a single stellar population. We conclude that, while there is some evidence for tidal stripping at large radius, the dynamical mass of Palomar 13 is consistent with its stellar mass and neither significant dark matter, nor extreme tidal heating, is required to explain the cluster dynamics. The data presented herein were obtained at the W. M. Keck Observatory, which is operated as a

  17. Development of X-ray mini-probes for the Digiray RGX system

    International Nuclear Information System (INIS)

    Wojcik, R.; Kross, B.; Majewski, L.; Majewski, S.; Weisenberger, A.G.; Zorn, C.; Birt, E.A.; Parker, F.R.; Winfree, W.P.; Albert, R.D.; Albert, T.M.

    1994-01-01

    We have developed and tested a variety of X-ray mini-probes for the Reverse Geometry X-radiography trademark ,1 (RGX) system each having their own advantages and disadvantages. These mini-probes consist of small scintillators (as small as 2 mm in diameter and 5 mm long) attached to optical light guides (as long as 14 m) coupled to photomultipliers. Images produced with these probes show that even smaller probes and/or longer light guides may be fashioned. Such probes may be useful in both non-destructive evaluation and medical imaging. ((orig.))

  18. Genome-wide scan identifies variant in TNFSF13 associated with serum IgM in a healthy Chinese male population.

    Directory of Open Access Journals (Sweden)

    Ming Yang

    Full Text Available IgM provides a first line of defense during microbial infections. Serum IgM levels are detected routinely in clinical practice. And IgM is a genetically complex trait. We conducted a two-stage genome-wide association study (GWAS to identify genetic variants affecting serum IgM levels in a Chinese population of 3495, including 1999 unrelated subjects in the first stage and 1496 independent individuals in the second stage. Our data show that a common single nucleotide polymorphism (SNP, rs11552708 located in the TNFSF13 gene was significantly associated with IgM levels (p = 5.00×10(-7 in first stage, p = 1.34×10(-3 in second stage, and p = 4.22×10(-9 when combined. Besides, smoking was identified to be associated with IgM levels in both stages (P0.05. It is suggested that TNFSF13 may be a susceptibility gene affecting serum IgM levels in Chinese male population.

  19. Repeatability of pachymetric mapping using fourier domain optical coherence tomography in corneas with opacities.

    Science.gov (United States)

    Samy El Gendy, Nehal M; Li, Yan; Zhang, Xinbo; Huang, David

    2012-04-01

    To evaluate the repeatability of Fourier domain optical coherence tomography (OCT) pachymetric mapping in patients with corneal opacities and to assess the reliability of Fourier domain OCT with 830 nm wavelength as a pachymetric measurement tool in opaque corneas. A Fourier domain OCT system was used to map the corneal thickness of patients with corneal scars or dystrophy. A retrospective study of a consecutive series was conducted. The repeatability was measured using pooled standard deviation of repeated measurements. A slit-scanning tomography device provided pachymetric mapping for comparison. Seventeen eyes of 12 patients with corneal scars (7 trauma and 3 post infection) or dystrophy (2 Reis-Bucklers and 5 granular dystrophy) were included. The posterior corneal boundary was detectable in all cases. The average corneal thickness measured by OCT was 536 ± 89 μm in central 2 mm area, 553 ± 76 μm in pericentral 2- to 5-mm area, and 508 ± 93 μm for the minimum corneal thickness. The slit-scanning tomography central corneal thickness, 433 ± 111 μm, was significantly lower than OCT readings (mean difference -91.1 ± 33.3 μm, P = 0.002). Repeatability of the OCT measurements was 2.1 μm centrally and 1.2 μm pericentrally. Pachymetric mapping with Fourier domain OCT was highly repeatable. Fourier domain OCT is a reliable pachymetric tool in opaque corneas. In comparison, corneal thickness measured by the slit-scanning tomography is significantly thinner than those measured by the Fourier domain OCT in the presence of corneal opacities.

  20. Probing behaviors of Sitobion avenae (Hemiptera: Aphididae on enhanced UV-B irradiated plants

    Directory of Open Access Journals (Sweden)

    Hu Zu-Qing

    2013-01-01

    Full Text Available UV-B induced changes in plants can influence sap-feeding insects through mechanisms that have not been studied. Herein the grain aphid, Sitobion avenae (Fabricius (Hemiptera: Aphididae, was monitored on barley plants under the treatments of control [0 kJ/ (m2.d], ambient UV-B [60 kJ/ (m2.d], and enhanced UV-B [120 kJ/ (m2.d] irradiation. Electrical penetration graph (EPG techniques were used to record aphid probing behaviors. Enhanced UV-B irradiated plants negatively affected probing behaviors of S. avenae compared with control plants. In particular, phloem factors that could diminish sieve element acceptance appeared to be involved, as reflected by smaller number of phloem phase, shorter phloem ingestion, and fewer aphids reaching the sustained phloem ingestion phase (E2>10min. On the other hand, factors from leaf surface, epidermis, and mesophyll cannot be excluded, as reflected by higher number of non-probing, longer non-probing and pathway phase, and later the time to first probe.

  1. Enhanced antibody-dependent cellular phagocytosis by chimeric monoclonal antibodies with tandemly repeated Fc domains.

    Science.gov (United States)

    Nagashima, Hiroaki; Ootsubo, Michiko; Fukazawa, Mizuki; Motoi, Sotaro; Konakahara, Shu; Masuho, Yasuhiko

    2011-04-01

    We previously reported that chimeric monoclonal antibodies (mAbs) with tandemly repeated Fc domains, which were developed by introducing tandem repeats of Fc domains downstream of 2 Fab domains, augmented binding avidities for all Fcγ receptors, resulting in enhanced antibody (Ab)-dependent cellular cytotoxicity. Here we investigated regarding Ab-dependent cellular phagocytosis (ADCP) mediated by these chimeric mAbs, which is considered one of the most important mechanisms that kills tumor cells, using two-color flow cytometric methods. ADCP mediated by T3-Ab, a chimeric mAb with 3 tandemly repeated Fc domains, was 5 times more potent than that by native anti-CD20 M-Ab (M-Ab hereafter). Furthermore, T3-Ab-mediated ADCP was resistant to competitive inhibition by intravenous Ig (IVIG), although M-Ab-mediated ADCP decreased in the presence of IVIG. An Fcγ receptor-blocking study demonstrated that T3-Ab mediated ADCP via both FcγRIA and FcγRIIA, whereas M-Ab mediated ADCP exclusively via FcγRIA. These results suggest that chimeric mAbs with tandemly repeated Fc domains enhance ADCP as well as ADCC, and that Fc multimerization may significantly enhance the efficacy of therapeutic Abs. Copyright © 2010 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  2. Field measuring probe for SSC [Superconducting Super Collider] magnets

    International Nuclear Information System (INIS)

    Ganetis, G.; Herrera, J.; Hogue, R.; Skaritka, J.; Wanderer, P.; Willen, E.

    1987-03-01

    The field probe developed for measuring the field in SSC dipole magnets is an adaptation of the rotating tangential coil system in use at Brookhaven for several years. Also known as the MOLE, it is a self-contained room-temperature mechanism that is pulled through the aperture of the magnet with regular stops to measure the local field. Several minutes are required to measure the field at each point. The probe measures the multipole components of the field as well as the field angle relative to gravity. The sensitivity of the coil and electronics is such that the field up to the full 6.6 T excitation of the magnet as well as the field when warm with only 0.01 T excitation can be measured. Tethers are attached to both ends of the probe to carry electrical connections and to supply dry nitrogen to the air motors that rotate the tangential windings as well as the gravity sensor. A small computer is attached to the probe for control and for data collection, analysis and storage. Digital voltmeters are used to digitize the voltages from the rotating coil and several custom circuits control motor speeds in the probe. The overall diameter of the probe is approximately 2 cm and its length is 2.4 m; the field sensitive windings are 0.6 m in length

  3. TORE SUPRA fast reciprocating radio frequency probe (abstract)

    International Nuclear Information System (INIS)

    Thomas, C.E. Jr.; Harris, J.H.; Haste, G.R.; Kwon, M.; Goulding, R.H.; Hoffman, D.J.; Saoutic, B.; Becoulet, A.; Fraboulet, D.; Beaumont, B.; Kuus, H.; Ladurelle, L.; Pascal, J.Y.

    1995-01-01

    A fast reciprocating ion cyclotron range of frequencies (ICRF) probe was installed and operated on TORE SUPRA during 1992/1993. The body of the probe was originally used on the ATF experiment at Oak Ridge National Laboratory. The probe was adapted for use on TORE SUPRA, and mounted on one of the two fast reciprocating probe mounts. The probe consists of two orthogonal single-turn wire loops, mounted so that one loop senses toroidal rf magnetic fields and the other senses poloidal rf magnetic fields. The probe began operation in June, 1993. The probe active area is approximately 5 cm long by 2 cm, and the reciprocating mount has a slow stroke (5 cm/s) of 30 cm and a fast stroke (1.5 m/s) of about 10 cm. The probe was operated at distances from the plasma edge ranging from 30 to -5 cm (i.e., inside the last closed flux surface). The probe design, electronics, calibration, data acquisition, and data processing are discussed. First data from the probe are presented as a function of ICRF power, distance from the plasma, loop orientation, and other plasma parameters. Initial data show parametric instabilities do not play an important role for ICRF in the TORE SUPRA edge and scrape-off-layer (SOL) plasmas. Additionally it is observed that the probe signal has little or no dependence on position in the SOL/plasma edge

  4. Changes in Muscle and Cerebral Deoxygenation and Perfusion during Repeated Sprints in Hypoxia to Exhaustion

    Directory of Open Access Journals (Sweden)

    Sarah J. Willis

    2017-10-01

    Full Text Available During supramaximal exercise, exacerbated at exhaustion and in hypoxia, the circulatory system is challenged to facilitate oxygen delivery to working tissues through cerebral autoregulation which influences fatigue development and muscle performance. The aim of the study was to evaluate the effects of different levels of normobaric hypoxia on the changes in peripheral and cerebral oxygenation and performance during repeated sprints to exhaustion. Eleven recreationally active participants (six men and five women; 26.7 ± 4.2 years, 68.0 ± 14.0 kg, 172 ± 12 cm, 14.1 ± 4.7% body fat completed three randomized testing visits in conditions of simulated altitude near sea-level (~380 m, FIO2 20.9%, ~2000 m (FIO2 16.5 ± 0.4%, and ~3800 m (FIO2 13.3 ± 0.4%. Each session began with a 12-min warm-up followed by two 10-s sprints and the repeated cycling sprint (10-s sprint: 20-s recovery test to exhaustion. Measurements included power output, vastus lateralis, and prefrontal deoxygenation [near-infrared spectroscopy, delta (Δ corresponds to the difference between maximal and minimal values], oxygen uptake, femoral artery blood flow (Doppler ultrasound, hemodynamic variables (transthoracic impedance, blood lactate concentration, and rating of perceived exertion. Performance (total work, kJ; −27.1 ± 25.8% at 2000 m, p < 0.01 and −49.4 ± 19.3% at 3800 m, p < 0.001 and pulse oxygen saturation (−7.5 ± 6.0%, p < 0.05 and −18.4 ± 5.3%, p < 0.001, respectively decreased with hypoxia, when compared to 400 m. Muscle Δ hemoglobin difference ([Hbdiff] and Δ tissue saturation index (TSI were lower (p < 0.01 at 3800 m than at 2000 and 400 m, and lower Δ deoxyhemoglobin resulted at 3800 m compared with 2000 m. There were reduced changes in peripheral [Δ[Hbdiff], ΔTSI, Δ total hemoglobin ([tHb

  5. Development and Characterization of Complex DNA Fingerprinting Probes for the Infectious Yeast Candida dubliniensis

    Science.gov (United States)

    Joly, Sophie; Pujol, Claude; Rysz, Michal; Vargas, Kaaren; Soll, David R.

    1999-01-01

    Using a strategy to clone large genomic sequences containing repetitive elements from the infectious yeast Candida dubliniensis, the three unrelated sequences Cd1, Cd24, and Cd25, with respective molecular sizes of 15,500, 10,000, and 16,000 bp, were cloned and analyzed for their efficacy as DNA fingerprinting probes. Each generated a complex Southern blot hybridization pattern with endonuclease-digested genomic DNA. Cd1 generated an extremely variable pattern that contained all of the bands of the pattern generated by the repeat element RPS of Candida albicans. We demonstrated that Cd1 does not contain RPS but does contain a repeat element associated with RPS throughout the C. dubliniensis genome. The Cd1 pattern was the least stable over time both in vitro and in vivo and for that reason proved most effective in assessing microevolution. Cd24, which did not exhibit microevolution in vitro, was highly variable in vivo, suggesting in vivo-dependent microevolution. Cd25 was deemed the best probe for broad epidemiological studies, since it was the most stable over time, was the only truly C. dubliniensis-specific probe of the three, generated the most complex pattern, was distributed throughout all C. dubliniensis chromosomes, and separated a worldwide collection of 57 C. dubliniensis isolates into two distinct groups. The presence of a species-specific repetitive element in Cd25 adds weight to the already substantial evidence that C. dubliniensis represents a bona fide species. PMID:10074523

  6. Gene conversion homogenizes the CMT1A paralogous repeats

    Directory of Open Access Journals (Sweden)

    Hurles Matthew E

    2001-12-01

    Full Text Available Abstract Background Non-allelic homologous recombination between paralogous repeats is increasingly being recognized as a major mechanism causing both pathogenic microdeletions and duplications, and structural polymorphism in the human genome. It has recently been shown empirically that gene conversion can homogenize such repeats, resulting in longer stretches of absolute identity that may increase the rate of non-allelic homologous recombination. Results Here, a statistical test to detect gene conversion between pairs of non-coding sequences is presented. It is shown that the 24 kb Charcot-Marie-Tooth type 1A paralogous repeats (CMT1A-REPs exhibit the imprint of gene conversion processes whilst control orthologous sequences do not. In addition, Monte Carlo simulations of the evolutionary divergence of the CMT1A-REPs, incorporating two alternative models for gene conversion, generate repeats that are statistically indistinguishable from the observed repeats. Bounds are placed on the rate of these conversion processes, with central values of 1.3 × 10-4 and 5.1 × 10-5 per generation for the alternative models. Conclusions This evidence presented here suggests that gene conversion may have played an important role in the evolution of the CMT1A-REP paralogous repeats. The rates of these processes are such that it is probable that homogenized CMT1A-REPs are polymorphic within modern populations. Gene conversion processes are similarly likely to play an important role in the evolution of other segmental duplications and may influence the rate of non-allelic homologous recombination between them.

  7. FLOW CYTOMETRIC APPLICABILITY OF FLUORESCENT VITALITY PROBES ON PHYTOPLANKTON1.

    Science.gov (United States)

    Peperzak, Louis; Brussaard, Corina P D

    2011-06-01

    The applicability of six fluorescent probes (four esterase probes: acetoxymethyl ester of Calcein [Calcein-AM], 5-chloromethylfluorescein diacetate [CMFDA], fluorescein diacetate [FDA], and 2',7'-dichlorofluorescein diacetate [H 2 DCFDA]; and two membrane probes: bis-(1,3-dibutylbarbituric acid) trimethine oxonol [DiBAC 4 (3)] and SYTOX-Green) as vitality stains was tested on live and killed cells of 40 phytoplankton strains in exponential and stationary growth phases, belonging to 12 classes and consisting of four cold-water, 26 temperate, and four warm-water species. The combined live/dead ratios of all six probes indicated significant differences between the 12 plankton classes (P live/dead ratios of FDA and CMFDA were not significantly different from each other, and both performed better than Calcein-AM and H 2 DCFDA (P live/dead ratios) among all six probes belonged to nine genera from six classes of phytoplankton. In conclusion, FDA, CMFDA, DIBAC 4 (3), and SYTOX-Green represent a wide choice of vitality probes in the study of phytoplankton ecology, applicable in many species from different algal classes, originating from different regions and at different stages of growth. © 2011 Phycological Society of America.

  8. NASA's interstellar probe mission

    International Nuclear Information System (INIS)

    Liewer, P.C.; Ayon, J.A.; Wallace, R.A.; Mewaldt, R.A.

    2000-01-01

    NASA's Interstellar Probe will be the first spacecraft designed to explore the nearby interstellar medium and its interaction with our solar system. As envisioned by NASA's Interstellar Probe Science and Technology Definition Team, the spacecraft will be propelled by a solar sail to reach >200 AU in 15 years. Interstellar Probe will investigate how the Sun interacts with its environment and will directly measure the properties and composition of the dust, neutrals and plasma of the local interstellar material which surrounds the solar system. In the mission concept developed in the spring of 1999, a 400-m diameter solar sail accelerates the spacecraft to ∼15 AU/year, roughly 5 times the speed of Voyager 1 and 2. The sail is used to first bring the spacecraft to ∼0.25 AU to increase the radiation pressure before heading out in the interstellar upwind direction. After jettisoning the sail at ∼5 AU, the spacecraft coasts to 200-400 AU, exploring the Kuiper Belt, the boundaries of the heliosphere, and the nearby interstellar medium

  9. Characterization of a new M13 metallopeptidase from deep-sea Shewanella sp. E525-6 and mechanistic insight into its catalysis

    Directory of Open Access Journals (Sweden)

    Jin-Yu eYang

    2016-01-01

    Full Text Available Bacterial extracellular peptidases are important for bacterial nutrition and organic nitrogen degradation in the ocean. While many peptidases of the M13 family from terrestrial animals and bacteria are studied, there has been no report on M13 peptidases from marine bacteria. Here, we characterized an M13 peptidase, PepS, from the deep-sea sedimentary strain Shewanella sp. E525-6, and investigated its substrate specificity and catalytic mechanism. The gene pepS cloned from strain E525-6 contains 2085 bp and encodes an M13 metallopeptidase. PepS was expressed in Escherichia coli and purified. Among the characterized M13 peptidases, PepS shares the highest sequence identity (47% with Zmp1 from Mycobacterium tuberculosis, indicating that PepS is a new member of the M13 family. PepS had the highest activity at 30°C and pH 8.0. It retained 15% activity at 0°C. Its half life at 40°C was only 4 min. These properties indicate that PepS is a cold-adapted enzyme. The smallest substrate for PepS is pentapeptide, and it is probably unable to cleave peptides of more than 30 residues. PepS prefers to hydrolyze peptide bonds with P1’ hydrophobic residues. Structural and mutational analyses suggested that His531, His535 and Glu592 coordinate the catalytic zinc ion in PepS, Glu532 acts as a nucleophile, and His654 is probably involved in the transition state stabilization. Asp538 and Asp596 can stablize the orientations of His531 and His535, and Arg660 can stablize the orientation of Asp596. These results help in understanding marine bacterial peptidases and organic nitrogen degradation.

  10. Elevated maternal placental protein 13 serum levels at term of pregnancy in postpartum major hemorrhage (>1000 mLs). A prospective cohort study.

    Science.gov (United States)

    Farina, Antonio; Bernabini, Dalila; Zucchini, Cinzia; De Sanctis, Paola; Quezada, Maria Soledad; Mattioli, Mara; Rizzo, Nicola

    2017-09-01

    To compare placental protein 13 (PP13) levels in the serum of women with primary postpartum hemorrhage (PPH) with a control population. A prospective cohort study was conducted between May 2014 and May 2016 and included 435 pregnant women at term (38 weeks gestation) without any known risk factor and with normal labor. Multiples of median (MoM) were used to evaluate differences of the PP13 values between cases and controls. PP13 concentrations were adjusted for maternal and neonatal weight. Multivariable analysis was used to detect independent contribution of predictors of PPH. Fifteen had a major PPH >1000 mLs and represented the cases of the study. They were matched with 399 controls. Twenty-one patients who had a minor PPH (500-1000 mLs) were excluded. The mean observed rank in the PPH group was higher than that of controls (28.5 vs 13.5, P-value=.01). PP13 MoM values adjusted for maternal weight were higher than expected being 1.44±0.45 in PPH cases and 1.00±0.59 in controls (P-value .008). This difference was still significant even after adjustment for neonatal weight that represented a confounding variable. Higher PP13 levels are independently associated with major PPH >1000 mLs. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Design and performance verification of a wideband scalable dual-polarized probe for spherical near-field antenna measurements

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Kim, Oleksiy S.; Nielsen, Jeppe Majlund

    2012-01-01

    A wideband scalable dual-polarized probe designed by the Electromagnetic Systems group at the Technical University of Denmark is presented. The design was scaled and two probes were manufactured for the frequency bands 1-3 GHz and 0.4-1.2 GHz. The results of the acceptance tests of the 0.4-1.2 GHz...... probe are briefly discussed. Since these probes represent so-called higher-order antennas, applicability of the recently developed higher-order probe correction technique [3] for these probes was investigated. Extensive tests were carried out for two representative antennas under test using...

  12. Effects of repeated transport on Holstein calf post-transport behavior and feed intake.

    Science.gov (United States)

    Adams-Progar, A L; Friend, T H; Holub, G A; Krenek, A J; Garey, S M; Terrill, C L

    2015-02-01

    Previous studies have determined that stress causes decreases in feed intake and efficiency in livestock, but the effect of repeated transport on these parameters has not been well studied. This study determined how repeated transport affected calf post-transport behavior, feed intake, ADG, and feed conversion. Thirty-six 4-mo-old Holstein steer calves were housed in groups of 6 with each group randomly assigned to either transport or control treatments. Each calf was assigned to an individual Calan gate feeder and feed intake was recorded daily. Transport calves were transported for 6 h in their groups in a 7.3 by 2.4 m gooseneck trailer divided into 3 compartments, at an average density of 0.87 m/calf, every 7 d for 5 consecutive weeks. After return to their home pens, behavior was recorded for transported calves at 5-min intervals for 1 h. Calf ADG and feed conversion were analyzed in a mixed model ANOVA, whereas feed intake was analyzed as a repeated measure in a mixed model ANOVA. Post-transport, calves followed a pattern of drinking, eating, and then lying down. The highest (82 ± 5% calves) and lowest (0 ± 5% calves) incidences of eating behavior occurred 10 and 60 min post-transport, respectively. Control calves had a higher feed intake than transported calves overall (7.29 ± 0.22 kg for control and 6.91 ± 0.21 kg for transport; = 0.01), for the feeding posttreatment (6.78 ± 0.27 kg for control and 6.01 ± 0.28 kg for transport; = 0.007), and the day after treatment (7.83 ± 0.23 kg for control and 7.08 ± 0.15 kg for transport; = 0.02). Feed intake for the feeding post-transport for transport calves significantly decreased after the second transport but increased with each successive transport ( < 0.0001). Overall, control calves had higher ADG than transported calves (1.34 ± 0.13 kg/d for control and 1.15 ± 0.12 kg/d for transport; = 0.006). No significant difference ( = 0.12) between treatments was detected for feed conversion. These results

  13. Project and construction of counting system for neutron probe

    International Nuclear Information System (INIS)

    Monteiro, W.P.

    1985-01-01

    A counting system was developed for coupling neutron probe aiming to register pulses produced by slow neutron interaction in the detector. The neutron probe consists of fast neutron source, thermal neutron detector, amplifier circuit and pulse counting circuit. The counting system is composed by counting circuit, timer and signal circuit. (M.C.K.)

  14. A unique dual recognition hairpin probe mediated fluorescence amplification method for sensitive detection of uracil-DNA glycosylase and endonuclease IV activities.

    Science.gov (United States)

    Wu, Yushu; Yan, Ping; Xu, Xiaowen; Jiang, Wei

    2016-03-07

    Uracil-DNA glycosylase (UDG) and endonuclease IV (Endo IV) play cooperative roles in uracil base-excision repair (UBER) and inactivity of either will interrupt the UBER to cause disease. Detection of UDG and Endo IV activities is crucial to evaluate the UBER process in fundamental research and diagnostic application. Here, a unique dual recognition hairpin probe mediated fluorescence amplification method was developed for sensitively and selectively detecting UDG and Endo IV activities. For detecting UDG activity, the uracil base in the probe was excised by the target enzyme to generate an apurinic/apyrimidinic (AP) site, achieving the UDG recognition. Then, the AP site was cleaved by a tool enzyme Endo IV, releasing a primer to trigger rolling circle amplification (RCA) reaction. Finally, the RCA reaction produced numerous repeated G-quadruplex sequences, which interacted with N-methyl-mesoporphyrin IX to generate an enhanced fluorescence signal. Alternatively, for detecting Endo IV activity, the uracil base in the probe was first converted into an AP site by a tool enzyme UDG. Next, the AP site was cleaved by the target enzyme, achieving the Endo IV recognition. The signal was then generated and amplified in the same way as those in the UDG activity assay. The detection limits were as low as 0.00017 U mL(-1) for UDG and 0.11 U mL(-1) for Endo IV, respectively. Moreover, UDG and Endo IV can be well distinguished from their analogs. This method is beneficial for properly evaluating the UBER process in function studies and disease prognoses.

  15. Validity criteria for the diagnosis of fatty liver by M probe-based controlled attenuation parameter.

    Science.gov (United States)

    Wong, Vincent Wai-Sun; Petta, Salvatore; Hiriart, Jean-Baptiste; Cammà, Calogero; Wong, Grace Lai-Hung; Marra, Fabio; Vergniol, Julien; Chan, Anthony Wing-Hung; Tuttolomondo, Antonino; Merrouche, Wassil; Chan, Henry Lik-Yuen; Le Bail, Brigitte; Arena, Umberto; Craxì, Antonio; de Lédinghen, Victor

    2017-09-01

    Controlled attenuation parameter (CAP) can be performed together with liver stiffness measurement (LSM) by transient elastography (TE) and is often used to diagnose fatty liver. We aimed to define the validity criteria of CAP. CAP was measured by the M probe prior to liver biopsy in 754 consecutive patients with different liver diseases at three centers in Europe and Hong Kong (derivation cohort, n=340; validation cohort, n=414; 101 chronic hepatitis B, 154 chronic hepatitis C, 349 non-alcoholic fatty liver disease, 37 autoimmune hepatitis, 49 cholestatic liver disease, 64 others; 277 F3-4; age 52±14; body mass index 27.2±5.3kg/m 2 ). The primary outcome was the diagnosis of fatty liver, defined as steatosis involving ≥5% of hepatocytes. The area under the receiver-operating characteristics curve (AUROC) for CAP diagnosis of fatty liver was 0.85 (95% CI 0.82-0.88). The interquartile range (IQR) of CAP had a negative correlation with CAP (r=-0.32, psteatosis was lower among patients with body mass index ≥30kg/m 2 and F3-4 fibrosis. The validity of CAP for the diagnosis of fatty liver is lower if the IQR of CAP is ≥40dB/m. Lay summary: Controlled attenuation parameter (CAP) is measured by transient elastography (TE) for the detection of fatty liver. In this large study, using liver biopsy as a reference, we show that the variability of CAP measurements based on its interquartile range can reflect the accuracy of fatty liver diagnosis. In contrast, other clinical factors such as adiposity and liver enzyme levels do not affect the performance of CAP. Copyright © 2017 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  16. Is Transducer Hygiene sufficient when Vaginal Probes are used in the Clinical Routine?

    Science.gov (United States)

    Merz, E

    2016-04-01

    Vaginal ultrasound probes are semi-critical Group A medical products which must be disinfected following the manufacturer's instructions after every patient examination. According to the "Essential Requirements for Medical Devices (Directive 93/42/EEC, Annex I, paragraph 13)" the manufacturer's instructions for use for reusable products must contain suitable instructions for preparation processes. This presumes both an effective and material-compatible method. Evidence of effectiveness must be validated.In the Editorial in issue 1 Ultraschall in der Medizin/European Journal of Ultrasound 2005 we discussed the topic of transducer hygiene and stated that proper handling and cleaning as well as disinfection of probes in daily use are indispensable. This applies particularly to vaginal ultrasound probes routinely used in gynecological and obstetrical clinics, gynecological practices as well as IVF centers Normally the probe used in a transvaginal ultrasound examination is covered with a latex protective cover (with CE marking) which contains a certain amount of ultrasound gel. After the examination, the cover is removed and disposed of, and the gel is removed from the transducer. Since handling of the probe, ultrasound gel and cover can result in smear infections and cross-contamination with various pathogens (e. g. MRSA, HBV, HCV, HIV, herpes papilloma and cytomegalic viruses), after the protective cover is removed, the probe must be cleaned and subjected to disinfection with a bactericidal, fungicidal and virucidal effect. This is especially important in the event the cover ruptures during the vaginal examination, and the probe comes into direct contact with vaginal secretions or blood. The same likewise applies if the sterile protective cover is perforated during a follicular puncture. Usually special bactericidal, levurocidal and virucidal wipes or special submersion disinfection methods are available for disinfecting the vaginal ultrasound probes 11. Using

  17. IMHEX fuel cell repeat component manufacturing continuous improvement accomplishments

    Energy Technology Data Exchange (ETDEWEB)

    Jakaitis, L.A.; Petraglia, V.J.; Bryson, E.S. [M-C Power Corp., Burr Ridge, IL (United States)] [and others

    1996-12-31

    M-C Power is taking a power generation technology that has been proven in the laboratory and is making it a commercially competitive product. There are many areas in which this technology required scale up and refinement to reach the market entry goals for the IMHEX{reg_sign} molten carbonate fuel cell power plant. One of the primary areas that needed to be addressed was the manufacturing of the fuel cell stack. Up to this point, the fuel cell stack and associated components were virtually hand made for each system to be tested. M-C Power has now continuously manufactured the repeat components for three 250 kW stacks. M-C Power`s manufacturing strategy integrated both evolutionary and revolutionary improvements into its comprehensive commercialization effort. M-C Power`s objectives were to analyze and continuously improve stack component manufacturing and assembly techniques consistent with established specifications and commercial scale production requirements. Evolutionary improvements are those which naturally occur as the production rates are increased and experience is gained. Examples of evolutionary (learning curve) improvements included reducing scrap rates and decreasing raw material costs by buying in large quantities. Revolutionary improvements result in significant design and process changes to meet cost and performance requirements of the market entry system. Revolutionary changes often involve identifying new methods and developing designs to accommodate the new process. Based upon our accomplishments, M-C Power was able to reduce the cost of continuously manufactured fuel cell repeat components from the first to third 250 kW stack by 63%. This paper documents the continuous improvement accomplishments realized by M-C Power during IMHEX{reg_sign} fuel cell repeat component manufacturing.

  18. Tools to probe the universe

    International Nuclear Information System (INIS)

    Lagage, P.O.; Augueres, J.L.; Amiaux, J.; Cara, Ch.; Fontignie, J.; Rio, Y.; Fermon, C.; Pannetier-Lecoeur, M.; De Vismes, A.; Cordier, B.; Fesquet, M.; Ferrando, Ph.; Authier, M.; Pantin, E.; Glicenstein, J.F.; Boulade, O.; Refregier, A.; Stolarczyk, Th.; Agnese, P.; Rodriguez, L.; Agnese, P.; Pigot, C.; Duband, L.; Limousin, O.; Delagnes, E.; Turck-Chieze, S.; Carton, P.H.; Starck, J.L.; Bournaud, F.; Teyssier, R.; Audit, E.; Brun, A.S.; Leca, P.; Menache, Ch.; Pomarede, D.; Thooris, B.; Meis, C.

    2009-01-01

    This special issue of Clefs CEA journal is entirely devoted to astrophysics and to the exploration and probing of the Universe. The second part of this dossier, described here, makes a status of the tools used to probe the universe: telescopes, imaging spectrometers, data processing and simulation. Content: A - Telescopes of the future: 1. Seeing further out: JWST: looking back on a past 13 billion years old, Space specifics: the learning curve to know-how, Fabricating a corona-graph mask, SVOM, a satellite to detect the explosions of the first stars to be formed in the Universe; 2. Seeing more precisely: SIMBOL-X, pioneering formation flying, ELT/METIS, a 42-meter giant, One hundred telescopes for the CTA arrays; 3. Seeing wider: Euclid, mapping the extragalactic sky, ANTARES: the neutrino, another cosmic messenger; B - The new generation of imaging spectrometers: Observing the Universe in the submillimeter spectral region, The X-ray Universe, Space cryo-coolers, Out in the extreme, tumultuous Universe, Probing the Sun with GOLF-NG, Focus: From light to imagery; C - Data analysis in astrophysics; D - Numerical simulation in astrophysics: Information technology and theoretical predictions in astrophysics, Supercomputers for a better understanding of the Universe, The visualization of astrophysical simulations, Godunov, a numerical platform for education and research

  19. Analysis of simple sequence repeats in the Gaeumannomyces graminis var. tritici genome and the development of microsatellite markers.

    Science.gov (United States)

    Li, Wei; Feng, Yanxia; Sun, Haiyan; Deng, Yuanyu; Yu, Hanshou; Chen, Huaigu

    2014-11-01

    Understanding the genetic structure of Gaeumannomyces graminis var. tritici is essential for the establishment of efficient disease control strategies. It is becoming clear that microsatellites, or simple sequence repeats (SSRs), play an important role in genome organization and phenotypic diversity, and are a large source of genetic markers for population genetics and meiotic maps. In this study, we examined the G. graminis var. tritici genome (1) to analyze its pattern of SSRs, (2) to compare it with other plant pathogenic filamentous fungi, such as Magnaporthe oryzae and M. poae, and (3) to identify new polymorphic SSR markers for genetic diversity. The G. graminis var. tritici genome was rich in SSRs; a total 13,650 SSRs have been identified with mononucleotides being the most common motifs. In coding regions, the densities of tri- and hexanucleotides were significantly higher than in noncoding regions. The di-, tri-, tetra, penta, and hexanucleotide repeats in the G. graminis var. tritici genome were more abundant than the same repeats in M. oryzae and M. poae. From 115 devised primers, 39 SSRs are polymorphic with G. graminis var. tritici isolates, and 8 primers were randomly selected to analyze 116 isolates from China. The number of alleles varied from 2 to 7 and the expected heterozygosity (He) from 0.499 to 0.837. In conclusion, SSRs developed in this study were highly polymorphic, and our analysis indicated that G. graminis var. tritici is a species with high genetic diversity. The results provide a pioneering report for several applications, such as the assessment of population structure and genetic diversity of G. graminis var. tritici.

  20. Scientific Value of a Saturn Atmospheric Probe Mission

    Science.gov (United States)

    Simon-Miller, A. A.; Lunine, J. I.; Atreya, S. K.; Spilker, T. R.; Coustenis, A.; Atkinson, D. H.

    2012-01-01

    Atmospheric entry probe mISSions to the giant planets can uniquely discriminate between competing theories of solar system formation and the origin and evolution of the giant planets and their atmospheres. This provides for important comparative studies of the gas and ice giants, and to provide a laboratory for studying the atmospheric chemistries, dynamics, and interiors of all the planets including Earth. The giant planets also represent a valuable link to extrasolar planetary systems. As outlined in the recent Planetary Decadal Survey, a Saturn Probe mission - with a shallow probe - ranks as a high priority for a New Frontiers class mission [1].

  1. CAG repeat polymorphisms in the androgen receptor and breast cancer risk in women: a meta-analysis of 17 studies

    Directory of Open Access Journals (Sweden)

    Mao Q

    2015-08-01

    Full Text Available Qixing Mao,1–3,* Mantang Qiu,1–3,* Gaochao Dong,3 Wenjie Xia,1–3 Shuai Zhang,1,3 Youtao Xu,1,3 Jie Wang,3 Yin Rong,1,3 Lin Xu,1,3 Feng Jiang1,3 1Department of Thoracic Surgery, Nanjing Medical University Affiliated Cancer Institute of Jiangsu Province, 2Fourth Clinical College of Nanjing Medical University, 3Jiangsu Key Laboratory of Molecular and Translational Cancer Research, Nanjing, People’s Republic of China *These authors contributed equally to this work Abstract: The association between polymorphic CAG repeats in the androgen receptor gene in women and breast cancer susceptibility has been studied extensively. However, the conclusions regarding this relationship remain conflicting. The purpose of this meta-analysis was to identify whether androgen receptor CAG repeat lengths were related to breast cancer susceptibility. The MEDLINE, PubMed, and EMBASE databases were searched through to December 2014 to identify eligible studies. Data and study quality were rigorously assessed by two investigators according to the Newcastle-Ottawa Quality Assessment Scale. The publication bias was assessed by the Begg’s test. Seventeen eligible studies were included in this meta-analysis. The overall analysis suggested no association between CAG polymorphisms and breast cancer risk (odds ratio [OR] 1.031, 95% confidence interval [CI] 0.855–1.245. However, in the subgroup analysis, we observed that long CAG repeats significantly increased the risk of breast cancer in the Caucasian population (OR 1.447, 95% CI 1.089–1.992. Additionally, the risk was significantly increased in Caucasian women carrying two alleles with CAG repeats ≥22 units compared with those with two shorter alleles (OR 1.315, 95% CI 1.014–1.707. These findings suggest that long CAG repeats increase the risk of breast cancer in Caucasian women. However, larger scale case-control studies are needed to validate our results. Keywords: androgen, CAG repeat polymorphism, women

  2. Lymphoscintigraphy and intra-operative gamma probe in detection of sentinel lymph node for breast cancer surgery

    International Nuclear Information System (INIS)

    Le Ngoc Ha; Le Manh Ha; Bui Quang Bieu

    2011-01-01

    Sentinel lymph node biopsy (SLNB) has been emerged as a highly accurate method of axillary staging in management of breast cancer patients. Sentinel lymph node detection (SLND) by lymphoscintigraphy and intra-operative gamma probe for SLNB have been widely used in the world. Objectives: the purpose of our study was to evaluate the result of techniques using lymphoscintigraphy and intra-operative gamma probe for SLND in breast carcinoma patients. Materials and Methods: 102 patients with early breast carcinoma were enrolled in the study. Lymphoscintigraphy using Tc-99m-human serum albumin colloid, intra-operative gamma probe were undergone for localization and SLNB. Total axillary lymph node was dissected in breast cancer surgery. Results: The success rate of lymphoscintigraphy and SLND was 98.0% (100/102 patients), mean number of sentinel lymph node (SLN)/patient was 1.56 ± 0.79 (ranged 1 - 3), number of lymphatic vessel/SLN was 1.5 ± 0.69 (ranged 1 - 4) and mean time for SLND on lymphoscintigraphy was 4.21 ± 13.4 minutes (2 - 15 minutes). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of radio-guided SLNB for axillary staging was 100%, 70.6%, 41.2%, 100% and 75.6 % respectively. Conclusions: radio-guided SLNB by lymphoscintigraphy and intra-operative gamma probe is feasible and reliable for axillary staging in early breast carcinoma patients. (author)

  3. The Involvement of Mutual Inhibition of ERK and mTOR in PLCγ1-Mediated MMP-13 Expression in Human Osteoarthritis Chondrocytes

    Directory of Open Access Journals (Sweden)

    Zejun Liu

    2015-08-01

    Full Text Available The issue of whether ERK activation determines matrix synthesis or degradation in osteoarthritis (OA pathogenesis currently remains controversial. Our previous study shows that PLCγ1 and mTOR are involved in the matrix metabolism of OA cartilage. Investigating the interplays of PLCγ1, mTOR and ERK in matrix degradation of OA will facilitate future attempts to manipulate ERK in OA prevention and therapy. Here, cultured human normal chondrocytes and OA chondrocytes were treated with different inhibitors or transfected with expression vectors, respectively. The levels of ERK, p-ERK, PLCγ1, p-PLCγ1, mTOR, p-mTOR and MMP-13 were then evaluated by Western blotting analysis. The results manifested that the expression level of ERK in human OA chondrocytes was lower than that in human normal articular chondrocytes, and the up-regulation of ERK could promote matrix synthesis, including the decrease in MMP-13 level and the increase in Aggrecan level in human OA chondrocytes. Furthermore, the PLCγ1/ERK axis and a mutual inhibition of mTOR and ERK were observed in human OA chondrocytes. Interestingly, activated ERK had no inhibitory effect on MMP-13 expression in PLCγ1-transformed OA chondrocytes. Combined with our previous study, the non-effective state of ERK activation by PLCγ1 on MMP-13 may be partly attributed to the inhibition of the PLCγ1/mTOR axis on the PLCγ1/ERK axis. Therefore, the study indicates that the mutual inhibition of ERK and mTOR is involved in PLCγ1-mediated MMP-13 expression in human OA chondrocytes, with important implication for the understanding of OA pathogenesis as well as for its prevention and therapy.

  4. Assessing the inter- and intra-animal variability of in vivo OsteoProbe skeletal measures in untreated dogs

    Directory of Open Access Journals (Sweden)

    Erin M.B. McNerny

    2016-12-01

    Full Text Available The OsteoProbe is a second-generation reference point indentation (RPI device without a reference probe that is designed to simplify RPI testing for clinical use. Successful clinical implementation of the OsteoProbe would benefit from a better understanding of how its output, bone material strength index (BMSi, relates to the material properties of bone and under what conditions it reliably correlates with fracture risk. Large animal models have the potential to help fill this knowledge gap, as cadaveric studies are retrospective and limited by incomplete patient histories (including the potential use of bone matrix altering drugs such as bisphosphonates. The goal of this study was to assess the intra and inter-animal variability of OsteoProbe measures in untreated beagle dogs (n = 12, and to evaluate this variability in comparison to traditional mechanical testing. OsteoProbe measurements were performed in vivo on the left tibia of each dog and repeated 6 months later on the day of sacrifice. Within-animal variation of BMSi (CV of 5–10 indents averaged 8.9 and 9.0% at the first and second timepoints, respectively. In contrast, inter-animal variation of BMSi increased from 5.3% to 9.1%. The group variation of BMSi was on par with that of traditional 3-point mechanical testing; inter-animal variation was 10% for ultimate force, 13% for stiffness, and 12% for total work as measured on the femur. There was no significant change in mean BMSi after 6 months, but the individual change with time across the 12 dogs was highly variable, ranging from −12.4% to +21.7% (mean 1.6%, SD 10.6%. No significant correlations were found between in vivo tibia BMSi and femur mechanical properties measured by ex vivo 3-pt bending, but this may be a limitation of sample size or the tests being performed on different bones. No relationship was found between BMSi and tissue mineral density, but a strong positive correlation was found between BMSi and tibia

  5. D20S16 is a complex interspersed repeated sequence: Genetic and physical analysis of the locus

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, D.W.; Krawchuk, M.D.; Howard, T.D. [Wake Forest Univ., Winston-Salem, NC (United States)] [and others

    1995-01-20

    The genomic structure of the D20S16 locus has been evaluated using genetic and physical methods. D20S16, originally detected with the probe CRI-L1214, is a highly informative, complex restriction fragment length polymorphism consisting of two separate allelic systems. The allelic systems have the characteristics of conventional VNTR polymorphisms and are separated by recombination ({theta} = 0.02, Z{sub max} = 74.82), as demonstrated in family studies. Most of these recombination events are meiotic crossovers and are maternal in origin, but two, including deletion of the locus in a cell line from a CEPH family member, occur without evidence for exchange of flanking markers. DNA sequence analysis suggests that the basis of the polymorphism is variable numbers of a 98-bp sequence tandemly repeated with 87 to 90% sequence similarity between repeats. The 98-bp repeat is a dimer of 49 bp sequence with 45 to 98% identity between the elements. In addition, nonpolymorphic genomic sequences adjacent to the polymorphic 98-bp repeat tracts are also repeated but are not polymorphic, i.e., show no individual to individual variation. Restriction enzyme mapping of cosmids containing the CRI-L1214 sequence suggests that there are multiple interspersed repeats of the CRI-L1214 sequence on chromosome 20. The results of dual-color fluorescence in situ hybridization experiments with interphase nuclei are also consistent with multiple repeats of an interspersed sequence on chromosome 20. 23 refs., 6 figs.

  6. Yeast eIF4B binds to the head of the 40S ribosomal subunit and promotes mRNA recruitment through its N-terminal and internal repeat domains.

    Science.gov (United States)

    Walker, Sarah E; Zhou, Fujun; Mitchell, Sarah F; Larson, Victoria S; Valasek, Leos; Hinnebusch, Alan G; Lorsch, Jon R

    2013-02-01

    Eukaryotic translation initiation factor (eIF)4B stimulates recruitment of mRNA to the 43S ribosomal pre-initiation complex (PIC). Yeast eIF4B (yeIF4B), shown previously to bind single-stranded (ss) RNA, consists of an N-terminal domain (NTD), predicted to be unstructured in solution; an RNA-recognition motif (RRM); an unusual domain comprised of seven imperfect repeats of 26 amino acids; and a C-terminal domain. Although the mechanism of yeIF4B action has remained obscure, most models have suggested central roles for its RRM and ssRNA-binding activity. We have dissected the functions of yeIF4B's domains and show that the RRM and its ssRNA-binding activity are dispensable in vitro and in vivo. Instead, our data indicate that the 7-repeats and NTD are the most critical domains, which mediate binding of yeIF4B to the head of the 40S ribosomal subunit via interaction with Rps20. This interaction induces structural changes in the ribosome's mRNA entry channel that could facilitate mRNA loading. We also show that yeIF4B strongly promotes productive interaction of eIF4A with the 43S•mRNA PIC in a manner required for efficient mRNA recruitment.

  7. Differentiating inflamed and normal lungs by the apparent reaction rate constants of lactate dehydrogenase probed by hyperpolarized (13)C labeled pyruvate.

    Science.gov (United States)

    Xu, He N; Kadlececk, Stephen; Shaghaghi, Hoora; Zhao, Huaqing; Profka, Harilla; Pourfathi, Mehrdad; Rizi, Rahim; Li, Lin Z

    2016-02-01

    Clinically translatable hyperpolarized (HP) (13)C-NMR can probe in vivo enzymatic reactions, e.g., lactate dehydrogenase (LDH)-catalyzed reaction by injecting HP (13)C-pyruvate into the subject, which is converted to (13)C labeled lactate by the enzyme. Parameters such as (13)C-lactate signals and lactate-to-pyruvate signal ratio are commonly used for analyzing the HP (13)C-NMR data. However, the biochemical/biological meaning of these parameters remains either unclear or dependent on experimental settings. It is preferable to quantify the reaction rate constants with a clearer physical meaning. Here we report the extraction of the kinetic parameters of the LDH reaction from HP (13)C-NMR data and investigate if they can be potential predictors of lung inflammation. Male Sprague-Dawley rats (12 controls, 14 treated) were used. One dose of bleomycin (2.5 U/kg) was administered intratracheally to the treatment group. The lungs were removed, perfused, and observed by the HP-NMR technique, where a HyperSense dynamic nuclear polarization system was used to generate the HP (13)C-pyruvate for injecting into the lungs. A 20 mm (1)H/(13)C dual-tuned coil in a 9.4-T Varian vertical bore NMR spectrometer was employed to acquire the (13)C spectral data every 1 s over a time period of 300 s using a non-selective, 15-degree radiofrequency pulse. The apparent rate constants of the LDH reaction and their ratio were quantified by applying ratiometric fitting analysis to the time series data of (13)C labeled pyruvate and lactate. The apparent forward rate constant kp =(3.67±3.31)×10(-4) s(-1), reverse rate constant kl =(4.95±2.90)×10(-2) s(-1), rate constant ratio kp /kl =(7.53±5.75)×10(-3) for the control lungs; kp =(11.71±4.35)×10(-4) s(-1), kl =(9.89±3.89)×10(-2) s(-1), and kp /kl =(12.39±4.18)×10(-3) for the inflamed lungs at the 7(th) day post treatment. Wilcoxon rank-sum test showed that the medians of these kinetic parameters of the 7-day cohort were significantly

  8. Real-Time Probing of Structural Dynamics by Interaction between Chromophores

    DEFF Research Database (Denmark)

    Brogaard, Rasmus Y.; Møller, Klaus Braagaard; Sølling, Theis Ivan

    2011-01-01

    We present an investigation of structural dynamics in excited-state cations probed in real-time by femtosecond timeresolved ion photofragmentation spectroscopy. From photoelectron spectroscopy data on 1,3-dibromopropane we conclude that the pump pulse ionizes the molecule, populating an excited...

  9. Fluorescence In Situ Hybridization (FISH-Based Karyotyping Reveals Rapid Evolution of Centromeric and Subtelomeric Repeats in Common Bean (Phaseolus vulgaris and Relatives

    Directory of Open Access Journals (Sweden)

    Aiko Iwata-Otsubo

    2016-04-01

    Full Text Available Fluorescence in situ hybridization (FISH-based karyotyping is a powerful cytogenetics tool to study chromosome organization, behavior, and chromosome evolution. Here, we developed a FISH-based karyotyping system using a probe mixture comprised of centromeric and subtelomeric satellite repeats, 5S rDNA, and chromosome-specific BAC clones in common bean, which enables one to unambiguously distinguish all 11 chromosome pairs. Furthermore, we applied the karyotyping system to several wild relatives and landraces of common bean from two distinct gene pools, as well as other related Phaseolus species, to investigate repeat evolution in the genus Phaseolus. Comparison of karyotype maps within common bean indicates that chromosomal distribution of the centromeric and subtelomeric satellite repeats is stable, whereas the copy number of the repeats was variable, indicating rapid amplification/reduction of the repeats in specific genomic regions. In Phaseolus species that diverged approximately 2–4 million yr ago, copy numbers of centromeric repeats were largely reduced or diverged, and chromosomal distributions have changed, suggesting rapid evolution of centromeric repeats. We also detected variation in the distribution pattern of subtelomeric repeats in Phaseolus species. The FISH-based karyotyping system revealed that satellite repeats are actively and rapidly evolving, forming genomic features unique to individual common bean accessions and Phaseolus species.

  10. Triage of HR-HPV positive women with minor cytological abnormalities: a comparison of mRNA testing, HPV DNA testing, and repeat cytology using a 4-year follow-up of a population-based study.

    Science.gov (United States)

    Persson, Maria; Elfström, K Miriam; Brismar Wendel, Sophia; Weiderpass, Elisabete; Andersson, Sonia

    2014-01-01

    Expression of the viral E6/E7 oncogenes of high-risk human papillomaviruses (HR-HPV) is necessary for malignant conversion and maintenance in cervical tissue. In order to determine whether HR-HPV E6/E7 mRNA testing more effectively predicts precancerous lesions and invasive cervical cancer than HR-HPV DNA testing, we aimed to compare triage using HR-HPV E6/E7 mRNA testing by APTIMA HPV Assay (APTIMA) to HPV16 DNA testing, HPV16/18 DNA testing, and repeat cytology. Liquid-based (PreservCyt) cell samples were obtained from HR-HPV-positive women diagnosed with atypical squamous cells of undetermined significance (ASCUS) and low-grade squamous intraepithelial lesions (LSIL) within the framework of the population-based cervical cancer screening program in Stockholm, Sweden. Samples were tested for HR-HPV E6/E7 mRNA by APTIMA (Gene-Probe Inc., San Diego, CA, USA). Women were followed up for 4 years after the index cytology via medical and laboratory records, and the Stockholm Oncology Center. Nine of 25 (36%) women in the ASCUS group, and 64 of 180 (36%) women in the LSIL group developed cervical intraepithelial neoplasia (CIN) grade 2 or worse during 4 years of follow-up. 162 (74%) women were APTIMA-positive, and APTIMA had the highest sensitivity to predict CIN2 or worse and CIN3 or worse in the ASCUS (77.8% and 100%) and LSIL (78.1 and 75.8%) groups, although specificity was insufficient (cytology were more specific than APTIMA. The results of this population-based study with comprehensive follow-up support the use of APTIMA as a triage test for women with ASCUS. More focused investigation is required for women with LSIL.

  11. Spin excitations in the quasi-two-dimensional charge-ordered insulator α -(BEDT-TTF ) 2I3 probed via 13C NMR

    Science.gov (United States)

    Ishikawa, Kyohei; Hirata, Michihiro; Liu, Dong; Miyagawa, Kazuya; Tamura, Masafumi; Kanoda, Kazushi

    2016-08-01

    The spin excitations from the nonmagnetic charge-ordered insulating state of α -(BEDT-TTF ) 2I3 at ambient pressure have been investigated by probing the static and low-frequency dynamic spin susceptibilities via site-selective nuclear magnetic resonance at 13C sites. The site-dependent values of the shift and the spin-lattice relaxation rate 1 /T1 below the charge-ordering transition temperature (TCO≈135 K ) demonstrate a spin density imbalance in the unit cell, in accord with the charge-density ratio reported earlier. The shift and 1 /T1 show activated temperature dependence with a static (shift) gap ΔS≈47 -52 meV and a dynamic (1 /T1 ) gap ΔR≈40 meV . The sizes of the gaps are well described in terms of a localized spin model, where spin-1/2 antiferromagnetic dimer chains are weakly coupled with each other.

  12. Chemical mechanical polisher technology for 300mm/0.18-0.13{mu}m semiconductor devices; 300mm/0.18-0.-0.13{mu}m sedai no CMP gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, M.; Kobayashi, F. [Ebara Corp., Tokyo (Japan)

    1998-10-20

    Described herein are problems involved in, and development points and measures for chemical mechanical polisher (CMP) technology for the generation of 300mm/0.18 to 0.13{mu}m semiconductor devices. Ebara has developed a CMP system for 300mm devices for I300I and Selete (semiconductor high-technologies). The polishing process conditions are set for the time being based on those for the 200mm devices, and the driver and machine structures are set at 2.25 times larger than those for the 200mm devices. Its space requirement is compacter at 1.3 times increase. The company has adopted a concept of `dry-in and dry-out,` which is not common for a CMP. This needs integration of the washer with the polisher, and aerodynamic designs for dust-free conditions. These are already developed for the 200mm devices, and applicable to the 300mm devices without causing any problem. The special chamber for the conventional CMP can be dispensed with, reducing cost. Expendables, such as slurry pad, are being developed to double their service lives and halve their consumption. 8 figs.

  13. Analysis of unknown cause subarachnoid hemorrhage with repeated negative angiogram

    International Nuclear Information System (INIS)

    Fujii, Mutsumi; Takasato, Yoshio; Masaoka, Hiroyuki; Ohta, Yoshihisa; Hayakawa, Takanori; Honma, Masato

    2006-01-01

    Seven hundred and fifty five cases of acute non-traumatic subarachnoid hemorrhage (SAH) were admitted to the department of neurosurgery of our hospital from July, 1995 to March, 2004. In 555 patients cerebral angiography was conducted but initial angiography was negative in 30 patients. Except 10 general condition poor patients, in 20 initial angiogram-negative patients were undergone repeated angiography. The cause of SAH could not be demonstrated in 13 cases. The SAH in perimesencephalic and non-perimesencephalic cisturns was seen in 7 and 6 cases, respectively. Occipital and/or neck pain on admission was statistically more common among patients with perimesencephalic SAH than those with non-perimesencephalic SAH (p=0.029), and the prognosis of perimesencephalic SAH was good. We conclude that repeat angiography should not be recommended in patients with perimesencephalic SAH. Patients with non-perimesencephalic SAH had a higher rate of complication. In the non-perimesencephalic group, 3 patients developed hydrocephalus and 3 patients had vasospasm, which were found by repeated angiography. Therefore, repeated angiography is recommended for better clinical outcome by early detection and management of serious complications in this group of patients. (author)

  14. Surface density dependence of PCR amplicon hybridization on PNA/DNA probe layers

    DEFF Research Database (Denmark)

    Yao, Danfeng; Kim, Junyoung; Yu, Fang

    2005-01-01

    at an intermediate sodium concentration (approximately 100 mM). These effects were mainly ascribed to the electrostatic cross talk among the hybridized DNA molecules and the secondary structure of PCR amplicons. For the negatively charged DNA probes, the hybridization reaction was subjected additionally to the DNA....../DNA electrostatic barrier, particularly in lower ionic strength range (e.g., 10 approximately 150 mM Na(+)). The electrostatic cross talk was shown to be largely reduced if the PNA probe layer was sufficiently diluted by following a strategic templated immobilization method. As a consequence, a pseudo...

  15. Myotonin protein-kinase [AGC]n trinucleotide repeat in seven nonhuman primates

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, G.; Sineo, L.; Pontieri, E. [Catholic Univ. of Rome (Italy)]|[Univ. of Milan (Italy)]|[Univ. Florence (Italy)] [and others

    1994-09-01

    Myotonic dystrophy (DM) is due to a genomic instability of a trinucleotide [AGC]n motif, located at the 3{prime} UTR region of a protein-kinase gene (myotonin protein kinase, MT-PK). The [AGC] repeat is meiotically and mitotically unstable, and it is directly related to the manifestations of the disorder. Although a gene dosage effect of the MT-PK has been demonstrated n DM muscle, the mechanism(s) by which the intragenic repeat expansion leads to disease is largely unknown. This non-standard mutational event could reflect an evolutionary mechanism widespread among animal genomes. We have isolated and sequenced the complete 3{prime}UTR region of the MT-PK gene in seven primates (macaque, orangutan, gorilla, chimpanzee, gibbon, owl monkey, saimiri), and examined by comparative sequence nucleotide analysis the [AGC]n intragenic repeat and the surrounding nucleotides. The genomic organization, including the [AGC]n repeat structure, was conserved in all examined species, excluding the gibbon (Hylobates agilis), in which the [AGC]n upstream sequence (GGAA) is replaced by a GA dinucleotide. The number of [AGC]n in the examined species ranged between 7 (gorilla) and 13 repeats (owl monkeys), with a polymorphism informative content (PIC) similar to that observed in humans. These results indicate that the 3{prime}UTR [AGC] repeat within the MT-PK gene is evolutionarily conserved, supporting that this region has important regulatory functions.

  16. The influence of age and repeated LPS administration on body temperature and the relation with interleukin-6 and IgM antibodies in broiler chickens

    OpenAIRE

    De Boever , Sandra; Beyaert , Rudi; Vandemaele , Fréderic; Baert , Kris; Duchateau , Luc; Goddeeris , Bruno; De Backer , Patrick; Croubels , Siska

    2008-01-01

    Abstract Our objective was to create a standardized and reproducible inflammation model in chickens in order to study the pharmacodynamics of several anti-pyretic and anti-inflammatory drugs. We studied the influence of age and repeated lipopolysaccharide (LPS) administration on body temperature and the correlation of this with concentrations of interleukin 6 (IL-6) and IgM antibodies against LPS in plasma of chickens. Three and five week old broilers were injected intravenously...

  17. Calibration of a four-hole pyramid probe and area traverse measurements in a short-duration transonic turbine cascade tunnel

    Science.gov (United States)

    Main, A. J.; Day, C. R. B.; Lock, G. D.; Oldfield, M. L. G.

    1996-08-01

    A four-hole pyramid probe has been calibrated for use in a short-duration transonic turbine cascade tunnel. The probe is used to create area traverse maps of total and static pressure, and pitch and yaw angles of the flow downstream of a transonic annular cascade. This data is unusual in that it was acquired in a short-duration (5 s of run time) annular cascade blowdown tunnel. A four-hole pyramid probe was used which has a 2.5 mm section head, and has the side faces inclined at 60° to the flow to improve transonic performance. The probe was calibrated in an ejector driven, perforated wall transonic tunnel over the Mach number range 0.5 1.2, with pitch angles from -20° to + 20° and yaw angles from-23° to +23°. A computer driven automatic traversing mechanism and data collection system was used to acquire a large probe calibration matrix (˜ 10,000 readings) of non dimensional pitch, yaw, Mach number, and total pressure calibration coefficients. A novel method was used to transform the probe calibration matrix of the raw coefficients into a probe application matrix of the physical flow variables (pitch, yaw, Mach number etc.). The probe application matrix is then used as a fast look-up table to process probe results. With negligible loss of accuracy, this method is faster by two orders of magnitude than the alternative of global interpolation on the raw probe calibration matrix. The blowdown tunnel (mean nozzle guide vane blade ring diameter 1.1 m) creates engine representative Reynolds numbers, transonic Mach numbers and high levels (≈ 13%) of inlet turbulence intensity. Contours of experimental measurements at three different engine relevant conditions and two axial positions have been obtained. An analysis of the data is presented which includes a necessary correction for the finite velocity of the probe. Such a correction is non trivial for the case of fast moving probes in compressible flow.

  18. A novel triple repeat mutant tau transgenic model that mimics aspects of pick's disease and fronto-temporal tauopathies.

    Directory of Open Access Journals (Sweden)

    Edward Rockenstein

    Full Text Available Tauopathies are a group of disorders leading to cognitive and behavioral impairment in the aging population. While four-repeat (4R Tau is more abundant in corticobasal degeneration, progressive supranuclear palsy, and Alzheimer's disease, three-repeat (3R Tau is the most abundant splice, in Pick's disease. A number of transgenic models expressing wild-type and mutant forms of the 4R Tau have been developed. However, few models of three-repeat Tau are available. A transgenic mouse model expressing three-repeat Tau was developed bearing the mutations associated with familial forms of Pick's disease (L266V and G272V mutations. Two lines expressing high (Line 13 and low (Line 2 levels of the three-repeat mutant Tau were analyzed. By Western blot, using antibodies specific to three-repeat Tau, Line 13 expressed 5-times more Tau than Line 2. The Tau expressed by these mice was most abundant in the frontal-temporal cortex and limbic system and was phosphorylated at residues detected by the PHF-1, AT8, CP9 and CP13 antibodies. The higher-expressing mice displayed hyperactivity, memory deficits in the water maze and alterations in the round beam. The behavioral deficits started at 6-8 months of age and were associated with a progressive increase in the accumulation of 3R Tau. By immunocytochemistry, mice from Line 13 displayed extensive accumulation of 3R Tau in neuronal cells bodies in the pyramidal neurons of the neocortex, CA1-3 regions, and dentate gyrus of the hippocampus. Aggregates in the granular cells had a globus appearance and mimic Pick's-like inclusions. There were abundant dystrophic neurites, astrogliosis and synapto-dendritic damage in the neocortex and hippocampus of the higher expresser line. The hippocampal lesions were moderately argyrophilic and Thioflavin-S negative. By electron microscopy, discrete straight filament aggregates were detected in some neurons in the hippocampus. This model holds promise for better understanding the

  19. Staffing to Maximize Profit for Call Centers with Impatient and Repeat-Calling Customers

    Directory of Open Access Journals (Sweden)

    Jun Gong

    2015-01-01

    Full Text Available Motivated by call center practice, we study the optimal staffing of many-server queues with impatient and repeat-calling customers. A call center is modeled as an M/M/s+M queue, which is developed to a behavioral queuing model in which customers come and go based on their satisfaction with waiting time. We explicitly take into account customer repeat behavior, which implies that satisfied customers might return and have an impact on the arrival rate. Optimality is defined as the number of agents that maximize revenues net of staffing costs, and we account for the characteristic that revenues are a direct function of staffing. Finally, we use numerical experiments to make certain comparisons with traditional models that do not consider customer repeat behavior. Furthermore, we indicate how managers might allocate staffing optimally with various customer behavior mechanisms.

  20. Repeatability and responsiveness of exercise tests in pulmonary arterial hypertension.

    Science.gov (United States)

    Mainguy, Vincent; Malenfant, Simon; Neyron, Anne-Sophie; Bonnet, Sébastien; Maltais, François; Saey, Didier; Provencher, Steeve

    2013-08-01

    Exercise tolerance in pulmonary arterial hypertension (PAH) is most commonly assessed by the 6-min walk test (6MWT). Whether endurance exercise tests are more responsive than the 6MWT remains unknown. 20 stable PAH patients (mean±sd age 53±15 years and mean pulmonary arterial pressure 44±16 mmHg) already on PAH monotherapy completed the 6MWT, the endurance shuttle walk test (ESWT) and the cycle endurance test (CET) before and after the addition of sildenafil citrate 20 mg three times daily or placebo for 28 days in a randomised double-blind crossover setting. Pre- or post-placebo tests were used to assess repeatability of each exercise test, whereas pre- or post-sildenafil citrate tests were used to assess their responsiveness. Sildenafil citrate led to placebo-corrected changes in exercise capacity of 18±25 m (p = 0.02), 58±235 s (p = 0.58) and 29±77 s (p = 0.09) for the 6MWT, the ESWT and the CET, respectively. The 6MWT was associated with a lower coefficient of variation between repeated measures (3% versus 18% versus 13%), resulting in a higher standardised response mean compared with endurance tests (0.72, 0.25 and 0.38 for the 6MWT, the ESWT and the CET, respectively). The 6MWT had the best ability to capture changes in exercise capacity when sildenafil citrate was combined with patients' baseline monotherapy, supporting its use as an outcome measure in PAH.

  1. A nonimaging scintillation probe to measure penile hemodynamics.

    Science.gov (United States)

    Zuckier, L S; Korupolu, G R; Gladshteyn, M; Sattenberg, R; Goldstein, R; Ricciardi, R; Goodwin, P; Melman, A; Blaufox, M D

    1995-12-01

    We have developed a penile nonimaging scintillation (PNIS) probe consisting of a plastic well-type scintillation crystal interfaced to a portable computer and acquisition board. This report describes the design of the PNIS probe, performance characteristics, mode of usage and illustrative results which demonstrate its capabilities. With the PNIS probe, penile blood-pool studies were performed in nine patients utilizing 3.7 MBq (100 microCi) autologous 99mTc-labeled red blood cells (RBCs). Venous blood standards were assayed to enable conversion of the count rate to volummetric measurements. Washin of peripherally administered 99mTc-RBCs was mathematically analyzed to estimate penile blood volume and cavernosal flow rate in the flaccid state. The rate of change of penile blood volume after intracavernosal vasodilators was used to generate measures of stimulated flow. A major advantage of this device over the gamma-camera is a 3300-fold increase in count rate sensitivity, which allows for markedly improved temporal resolution while significantly reducing the radiopharmaceutical dosage. Additionally, the PNIS probe is portable, economical and is not dependent on operator-defined regions of interest. Count rate sensitivity is relatively constant within the bore, with the exception of the proximal region adjacent to the opening, where geometric efficiency is reduced. The PNIS probe is an effective device for measuring penile activity in radionuclide studies, allowing for acquisition of time-activity curves of the penis during flaccid washin of peripherally labeled red blood cells and after pharmacologic stimulation to induce erection.

  2. A comparison of alternative 60-mer probe designs in an in-situ synthesized oligonucleotide microarray

    Directory of Open Access Journals (Sweden)

    Fairbanks Benjamin D

    2006-04-01

    Full Text Available Abstract Background DNA microarrays have proven powerful for functional genomics studies. Several technologies exist for the generation of whole-genome arrays. It is well documented that 25mer probes directed against different regions of the same gene produce variable signal intensity values. However, the extent to which this is true for probes of greater length (60mers is not well characterized. Moreover, this information has not previously been reported for whole-genome arrays designed against bacteria, whose genomes may differ substantially in characteristics directly affecting microarray performance. Results We report here an analysis of alternative 60mer probe designs for an in-situ synthesized oligonucleotide array for the GC rich, β-proteobacterium Burkholderia cenocepacia. Probes were designed using the ArrayOligoSel3.5 software package and whole-genome microarrays synthesized by Agilent, Inc. using their in-situ, ink-jet technology platform. We first validated the quality of the microarrays as demonstrated by an average signal to noise ratio of >1000. Next, we determined that the variance of replicate probes (1178 total probes examined of identical sequence was 3.8% whereas the variance of alternative probes (558 total alternative probes examined designs was 9.5%. We determined that depending upon the definition, about 2.4% of replicate and 7.8% of alternative probes produced outlier conclusions. Finally, we determined none of the probe design subscores (GC content, internal repeat, binding energy and self annealment produced by ArrayOligoSel3.5 were predictive or probes that produced outlier signals. Conclusion Our analysis demonstrated that the use of multiple probes per target sequence is not essential for in-situ synthesized 60mer oligonucleotide arrays designed against bacteria. Although probes producing outlier signals were identified, the use of ratios results in less than 10% of such outlier conclusions. We also determined that

  3. MMP-13 In-Vivo Molecular Imaging Reveals Early Expression in Lung Adenocarcinoma.

    Directory of Open Access Journals (Sweden)

    Mathieu Salaün

    Full Text Available Several matrix metalloproteinases (MMPs are overexpressed in lung cancer and may serve as potential targets for the development of bioactivable probes for molecular imaging.To characterize and monitor the activity of MMPs during the progression of lung adenocarcinoma.K-rasLSL-G12D mice were imaged serially during the development of adenocarcinomas using fluorescence molecular tomography (FMT and a probe specific for MMP-2, -3, -9 and -13. Lung tumors were identified using FMT and MRI co-registration, and the probe concentration in each tumor was assessed at each time-point. The expression of Mmp2, -3, -9, -13 was quantified by qRT-PCR using RNA isolated from microdissected tumor cells. Immunohistochemical staining of overexpressed MMPs in animals was assessed on human lung tumors.In mice, 7 adenomas and 5 adenocarcinomas showed an increase in fluorescent signal on successive FMT scans, starting between weeks 4 and 8. qRT-PCR assays revealed significant overexpression of only Mmp-13 in mice lung tumors. In human tumors, a high MMP-13 immunostaining index was found in tumor cells from invasive lesions (24/27, but in none of the non-invasive (0/4 (p=0.001.MMP-13 is detected in early pulmonary invasive adenocarcinomas and may be a potential target for molecular imaging of lung cancer.

  4. MMP-13 In-Vivo Molecular Imaging Reveals Early Expression in Lung Adenocarcinoma

    Science.gov (United States)

    Salaün, Mathieu; Peng, Jing; Hensley, Harvey H.; Roder, Navid; Flieder, Douglas B.; Houlle-Crépin, Solène; Abramovici-Roels, Olivia; Sabourin, Jean-Christophe; Thiberville, Luc; Clapper, Margie L.

    2015-01-01

    Introduction Several matrix metalloproteinases (MMPs) are overexpressed in lung cancer and may serve as potential targets for the development of bioactivable probes for molecular imaging. Objective To characterize and monitor the activity of MMPs during the progression of lung adenocarcinoma. Methods K-rasLSL-G12D mice were imaged serially during the development of adenocarcinomas using fluorescence molecular tomography (FMT) and a probe specific for MMP-2, -3, -9 and -13. Lung tumors were identified using FMT and MRI co-registration, and the probe concentration in each tumor was assessed at each time-point. The expression of Mmp2, -3, -9, -13 was quantified by qRT-PCR using RNA isolated from microdissected tumor cells. Immunohistochemical staining of overexpressed MMPs in animals was assessed on human lung tumors. Results In mice, 7 adenomas and 5 adenocarcinomas showed an increase in fluorescent signal on successive FMT scans, starting between weeks 4 and 8. qRT-PCR assays revealed significant overexpression of only Mmp-13 in mice lung tumors. In human tumors, a high MMP-13 immunostaining index was found in tumor cells from invasive lesions (24/27), but in none of the non-invasive (0/4) (p=0.001). Conclusion MMP-13 is detected in early pulmonary invasive adenocarcinomas and may be a potential target for molecular imaging of lung cancer. PMID:26193700

  5. SNAP: Small Next-generation Atmospheric Probe Concept

    Science.gov (United States)

    Sayanagi, K. M.; Dillman, R. A.; Atkinson, D. H.; Li, J.; Saikia, S.; Simon, A. A.; Spilker, T. R.; Wong, M. H.; Hope, D.

    2017-12-01

    We present a concept for a small, atmospheric probe that could be flexibly added to future missions that orbit or fly-by a giant planet as a secondary payload, which we call the Small Next-generation Atmospheric Probe (SNAP). SNAP's main scientific objectives are to determine the vertical distribution of clouds and cloud-forming chemical species, thermal stratification, and wind speed as a function of depth. As a case study, we present the advantages, cost and risk of adding SNAP to the future Uranus Orbiter and Probe flagship mission; in combination with the mission's main probe, SNAP would perform atmospheric in-situ measurements at a second location, and thus enable and enhance the scientific objectives recommended by the 2013 Planetary Science Decadal Survey and the 2014 NASA Science Plan to determine atmospheric spatial variabilities. We envision that the science objectives can be achieved with a 30-kg entry probe 0.5m in diameter (less than half the size of the Galileo probe) that reaches 5-bar pressure-altitude and returns data to Earth via the carrier spacecraft. As the baseline instruments, the probe will carry an Atmospheric Structure Instrument (ASI) that measures the temperature, pressure and acceleration, a carbon nanotube-based NanoChem atmospheric composition sensor, and an Ultra-Stable Oscillator (USO) to conduct a Doppler Wind Experiment (DWE). We also catalog promising technologies currently under development that will strengthen small atmospheric entry probe missions in the future. While SNAP is applicable to multiple planets, we examine the feasibility, benefits and impacts of adding SNAP to the Uranus Orbiter and Probe flagship mission. Our project is supported by NASA PSDS3 grant NNX17AK31G.

  6. MMT/AO 5 μm IMAGING CONSTRAINTS ON THE EXISTENCE OF GIANT PLANETS ORBITING FOMALHAUT AT ∼13-40 AU

    International Nuclear Information System (INIS)

    Kenworthy, Matthew A.; Hinz, Philip M.; Meyer, Michael R.; Miller, Douglas L.; Sivanandam, Suresh; Freed, Melanie; Mamajek, Eric E.; Heinze, Aren N.

    2009-01-01

    A candidate ∼ Jup extrasolar planet was recently imaged by Kalas et al. using Hubble Space Telescope/Advanced Camera for Surveys and Keck II at 12.''7 (96 AU) separation from the nearby (d = 7.7 pc) young (∼200 Myr) A2V star Fomalhaut. Here, we report results from M-band (4.8 μm) imaging of Fomalhaut on 2006 December 5 using the Clio IR imager on the 6.5 m MMT with the adaptive secondary mirror. Our images are sensitive to giant planets at orbital radii comparable to the outer solar system (∼10-40 AU). Comparing our 5σ M-band photometric limits to theoretical evolutionary tracks for substellar objects, our results rule out the existence of planets with masses >2 M Jup from ∼13 to 40 AU and objects >13 M Jup from ∼8 to 40 AU.

  7. Microwave measurements of the time evolution of electron density in the T-11M tokamak

    International Nuclear Information System (INIS)

    Petrov, V.G.; Petrov, A.A.; Malyshev, A.Yu.; Markov, V.K.; Babarykin, A.V.

    2004-01-01

    Unambiguous diagnostics intended for measuring the time behavior of the electron density and monitoring the line-averaged plasma density in the T-11M tokamak are described. The time behavior of the plasma density in the T-11M tokamak is measured by a multichannel phase-jump-free microwave polarization interferometer based on the Cotton-Mouton effect. After increasing the number of simultaneously operating interferometer channels and enhancing the sensitivity of measurements, it became possible to measure the time evolution of the plasma density profile in the T-11M tokamak. The first results from such measurements in various operating regimes of the T-11M tokamak are presented. The measurement and data processing techniques are described, the measurement errors are analyzed, and the results obtained are discussed. We propose using a pulsed time-of-flight refractometer to monitor the average plasma density in the T-11M tokamak. The refractometer emits nanosecond microwave probing pulses with a carrier frequency that is higher than the plasma frequency and, thus, operates in the transmission mode. A version of the instrument has been developed with a carrier frequency of 140 GHz, which allows one to measure the average density in regimes with a nominal T-11M plasma density of (3-5) x 10 13 cm -3 . Results are presented from the first measurements of the average density in the T-11M tokamak with the help of a pulsed time-of-flight refractometer by probing the plasma in the equatorial plane in a regime with the reflection of the probing radiation from the inner wall of the vacuum chamber

  8. Imaging of Homeostatic, Neoplastic, and Injured Tissues by HA-Based Probes

    Science.gov (United States)

    Veiseh, Mandana; Breadner, Daniel; Ma, Jenny; Akentieva, Natalia; Savani, Rashmin C; Harrison, Rene; Mikilus, David; Collis, Lisa; Gustafson, Stefan; Lee, Ting-Yim; Koropatnick, James; Luyt, Leonard G.; Bissell, Mina J.; Turley, Eva A.

    2013-01-01

    An increase in hyaluronan (HA) synthesis, cellular uptake, and metabolism occurs during the remodeling of tissue microenvironments following injury and during disease processes such as cancer. We hypothesized that multimodality HA-based probes selectively target and detectably accumulate at sites of high HA metabolism, thus providing a flexible imaging strategy for monitoring disease and repair processes. Kinetic analyses confirmed favorable available serum levels of the probe following intravenous (i.v.) or subcutaneous (s.c.) injection. Nuclear (technetium-HA, 99mTc-HA, and iodine-HA, 125I-HA), optical (fluorescent Texas Red-HA, TR-HA), and magnetic resonance (gadolinium-HA, Gd-HA) probes imaged liver (99mTc-HA), breast cancer cells/xenografts (TR-HA, Gd-HA), and vascular injury (125I-HA, TR-HA). Targeting of HA probes to these sites appeared to result from selective HA receptor-dependent localization. Our results suggest that HA-based probes, which do not require polysaccharide backbone modification to achieve favorable half-life and distribution, can detect elevated HA metabolism in homeostatic, injured, and diseased tissues. PMID:22066590

  9. In Silico-Based Repositioning of Phosphinothricin as a Novel Technetium-99m Imaging Probe with Potential Anti-Cancer Activity.

    Science.gov (United States)

    Sakr, Tamer M; Khedr, Mohammed A; Rashed, Hassan M; Mohamed, Maged E

    2018-02-23

    l-Phosphinothricin (glufosinate or 2-amino-4-((hydroxy(methyl) phosphinyl) butyric acid ammonium salt (AHPB)), which is a structural analog of glutamate, is a recognized herbicide that acts on weeds through inhibition of glutamine synthetase. Due to the structural similarity between phosphinothricin and some bisphosphonates (BPs), this study focuses on investigating the possibility of repurposing phosphinothricin as a bisphosphonate analogue, particularly in two medicine-related activities: image probing and as an anti-cancer drug. As BP is a competitive inhibitor of human farnesyl pyrophosphate synthase (HFPPS), in silico molecular docking and dynamic simulations studies were established to evaluate the binding and stability of phosphinothricin with HFPPS, while the results showed good binding and stability in the active site of the enzyme in relation to alendronate. For the purpose of inspecting bone-tissue accumulation of phosphinothricin, a technetium ( 99m Tc)-phosphinothricin complex was developed and its stability and tissue distribution were scrutinized. The radioactive complex showed rapid, high and sustained uptake into bone tissues. Finally, the cytotoxic activity of phosphinothricin was tested against breast and lung cancer cells, with the results indicating cytotoxic activity in relation to alendronate. All the above results provide support for the use of phosphinothricin as a potential anti-cancer drug and of its technetium complex as an imaging probe.

  10. Development of techniques using DNA analysis method for detection/analysis of radiation-induced mutation. Development of an useful probe/primer and improvement of detection efficacy

    International Nuclear Information System (INIS)

    Maekawa, Hideaki; Tsuchida, Kozo; Hashido, Kazuo; Takada, Naoko; Kameoka, Yosuke; Hirata, Makoto

    1999-01-01

    Previously, it was demonstrated that detection of centromere became easy and reliable through fluorescent staining by FISH method using a probe of the sequence preserved in α-satelite DNA. Since it was, however, found inappropriate to detect dicentrics based on the relative amount of DNA probe on each chromosome. A prove which allows homogeneous detection of α-satelite DNA for each chromosome was constructed. A presumed sequence specific to kinetochore, CENP-B box was amplified by PCR method and the product DNA was used as a probe. However, the variation in amounts of probe DNA among chromosomes was decreased by only about 20%. Then, a program for image processing of the results obtained from FISH using α-satelite DNA was constructed to use as a marker for centromere. When compared with detection of abnormal chromosomes stained by the conventional method, calculation efficacy for only detection of centromere was improved by the use of this program. Calculation to discriminate the normal or not was still complicated and the detection efficacy was little improved. Chromosomal abnormalities in lymphocytes were used to detect the effects of radiation. In this method, it is needed to shift the phase of cells into metaphase. The mutation induced by radiation might be often repaired during shifting. To exclude this possibility, DNA extraction was conducted at a low temperature and immediately after exposure to 137 Cs, and a rapid genome detection method was established using the genome DNA. As the model genomes, the following three were used: 1) long chain repeated sequences widely dispersed over chromosome, 2) cluster genes, 3) single copy genes. The effects of radiation were detectable at 1-2 Gy for the long repeated sequences and at 7 Gy for the cluster genes, respectively, whereas no significant effects were observed at any Gy tested for the single copy genes. Amplification was marked in the cells exposed at 1-10 Gy (peak at 4 Gy), suggesting that these regions had

  11. HindIII RFLP on chromosome 8 detected with a calbindin 27 kDa cDNA probe, HBSC21

    Energy Technology Data Exchange (ETDEWEB)

    Parmentier, M; Vassart, G

    1988-10-11

    A 1.8 kb for EcoRI fragment of the human calbindin cDNA clone HBSC21 was subcloned into M13mp18 and used as a probe. HindIII identifies a 2 allele polymorphism with a band at 4.7 kb (A1) and a band at 4.3 kb (A2). A constant band is located at 5.3 kb. The calbindin 27 kDa gene was assigned to chromosome 8 using chinese hamster-human and mouse-human cell hybrids. Co-dominant segregation was demonstrated in 3 families (total of 20 individuals).

  12. A fast scanning probe for DIII--D

    International Nuclear Information System (INIS)

    Watkins, J.G.; Salmonson, J.; Moyer, R.; Doerner, R.; Lehmer, R.; Schmitz, L.; Hill, D.N.

    1992-01-01

    A fast reciprocating probe has been developed for DIII--D which can penetrate the separatrix during H mode with up to 5 MW of NBI heating. The probe has been designed to carry various sensor tips into the scrape-off layer at a velocity of 3 m/s and dwell motionless for a programmed period of time. The driving force is provided by a pneumatic cylinder charged with helium to facilitate greater mass flow. The first series of experiments have been done using a Langmuir probe head with five graphite tips to measure radial profiles of n e , T e , φ f , n e , and φ f . The amplitude and phase of the fluctuating quantities are measured by using specially constructed vacuum compatible 5-kV coaxial transmission lines which allow us to extend the measurements into the MHz range. TTZ ceramic bearings and fast stroke bellows were also specially designed for the DIII--D probe. Initial measurements will be presented

  13. Rf8-Mediated T-urf13 Transcript Accumulation Coincides with a Pentatricopeptide Repeat Cluster on Maize Chromosome 2L

    Directory of Open Access Journals (Sweden)

    Julie Meyer

    2011-11-01

    Full Text Available Cytoplasmic male sterility (CMS is a maternally inherited inability to produce functional pollen. In Texas (T-cytoplasm maize ( L., CMS results from the action of the URF13 mitochondrial pore-forming protein encoded by the unique T- mitochondrial gene. Full or partial restoration of fertility to T-cytoplasm maize is mediated by the nuclear gene in combination with one of three other genes: , , or *. encodes a mitochondrial aldehyde dehydrogenase whereas , , and * are associated with the accumulation of distinctive T- mitochondrial transcripts. -associated RNA processing activity was mapped to a 4.55-Mbp region on chromosome 2L that contains 10 pentatricopeptide repeat (PPR encoding genes in the B73 5b.60 genome assembly. Genetic linkage analysis also indicated that * is positioned within this PPR cluster as well as , which restores USDA (S-cytoplasm maize. Partially male-fertile plants segregated for the presence or absence of the -associated T- 1.42- and 0.42-kbp transcripts, indicating that the RNA processing event associated with these transcripts is not necessary for anther exsertion. In addition, a statistically significant delay in flowering was observed between partially male-fertile and mostly male-fertile plants. Taken together, these new results indicate that -mediated male fertility is under the control of more than one nuclear locus.

  14. A comparison of various "housekeeping" probes for northern analysis of normal and osteoarthritic articular cartilage RNA.

    Science.gov (United States)

    Matyas, J R; Huang, D; Adams, M E

    1999-01-01

    Several approaches are commonly used to normalize variations in RNA loading on Northern blots, including: ethidium bromide (EthBr) fluorescence of 18S or 28S rRNA or autoradiograms of radioactive probes hybridized with constitutively expressed RNAs such as elongation factor-1alpha (ELF), glyceraldehyde-3-phosphate dehydrogenase (G3PDH), actin, 18S or 28S rRNA, or others. However, in osteoarthritis (OA) the amount of total RNA changes significantly and none of these RNAs has been clearly demonstrated to be expressed at a constant level, so it is unclear if any of these approaches can be used reliably for normalizing RNA extracted from osteoarthritic cartilage. Total RNA was extracted from normal and osteoarthritic cartilage and assessed by EthBr fluorescence. RNA was then transferred to a nylon membrane hybridized with radioactive probes for ELF, G3PDH, Max, actin, and an oligo-dT probe. The autoradiographic signal across the six lanes of a gel was quantified by scanning densitometry. When compared on the basis of total RNA, the coefficient of variation was lowest for 28S ethidium bromide fluorescence and oligo-dT (approximately 7%), followed by 18S ethidium bromide fluorescence and G3PDH (approximately 13%). When these values were normalized to DNA concentration, the coefficient of variation exceeded 50% for all signals. Total RNA and the signals for 18S, 28S rRNA, and oligo-dT all correlated highly. These data indicate that osteoarthritic chondrocytes express similar ratios of mRNA to rRNA and mRNA to total RNA as do normal chondrocytes. Of all the "housekeeping" probes, G3PDH correlated best with the measurements of RNA. All of these "housekeeping" probes are expressed at greater levels by osteoarthritic chondrocytes when compared with normal chondrocytes. Thus, while G3PDH is satisfactory for evaluating the amount of RNA loaded, its level of expression is not the same in normal and osteoarthritic chondrocytes.

  15. In vivo imaging of matrix metalloprotease 12 and matrix metalloprotease 13 activities in the mouse model of collagen-induced arthritis

    DEFF Research Database (Denmark)

    Lim, Ngee Han; Meinjohanns, Ernst; Bou-Gharios, George

    2014-01-01

    inhibitor GM6001 and specific synthetic inhibitors of MMP-12 and MMP-13. The probes were used to follow these enzyme activities in the collagen-induced arthritis (CIA) model in vivo. Results. The MMP-12- and MMP-13-activity probes (MMP12ap and MMP13ap, respectively) discriminated between the two enzymatic...... activities. The in vivo activation of these probes was inhibited by GM6001 and by their respective specific inhibitors. In the CIA model, MMP12ap activation peaked 5 days after disease onset and showed strong correlation with disease severity during this time (r = 0.85; p...

  16. Protease-activated quantum dot probes

    International Nuclear Information System (INIS)

    Chang, Emmanuel; Miller, Jordan S.; Sun, Jiantang; Yu, William W.; Colvin, Vicki L.; Drezek, Rebekah; West, Jennifer L.

    2005-01-01

    We have developed a novel nanoparticulate luminescent probe with inherent signal amplification upon interaction with a targeted proteolytic enzyme. This construct may be useful for imaging in cancer detection and diagnosis. In this system, quantum dots (QDs) are bound to gold nanoparticles (AuNPs) via a proteolytically degradable peptide sequence to non-radiatively suppress luminescence. A 71% reduction in luminescence was achieved with conjugation of AuNPs to QDs. Release of AuNPs by peptide cleavage restores radiative QD photoluminescence. Initial studies observed a 52% rise in luminescence over 47 h of exposure to 0.2 mg/mL collagenase. These probes can be customized for targeted degradation simply by changing the sequence of the peptide linker

  17. [Development of a Fluorescence Probe for Live Cell Imaging].

    Science.gov (United States)

    Shibata, Aya

    2017-01-01

    Probes that detect specific biological materials are indispensable tools for deepening our understanding of various cellular phenomena. In live cell imaging, the probe must emit fluorescence only when a specific substance is detected. In this paper, we introduce a new probe we developed for live cell imaging. Glutathione S-transferase (GST) activity is higher in tumor cells than in normal cells and is involved in the development of resistance to various anticancer drugs. We previously reported the development of a general strategy for the synthesis of probes for detection of GST enzymes, including fluorogenic, bioluminogenic, and 19 F-NMR probes. Arylsulfonyl groups were used as caging groups during probe design. The fluorogenic probes were successfully used to quantitate very low levels of GST activity in cell extracts and were also successfully applied to the imaging of microsomal MGST1 activity in living cells. The bioluminogenic and 19 F-NMR probes were able to detect GST activity in Escherichia coli cells. Oligonucleotide-templated reactions are powerful tools for nucleic acid sensing. This strategy exploits the target strand as a template for two functionalized probes and provides a simple molecular mechanism for multiple turnover reactions. We developed a nucleophilic aromatic substitution reaction-triggered fluorescent probe. The probe completed its reaction within 30 s of initiation and amplified the fluorescence signal from 0.5 pM target oligonucleotide by 1500 fold under isothermal conditions. Additionally, we applied the oligonucleotide-templated reaction for molecular releasing and peptide detection.

  18. Tissue imaging using full field optical coherence microscopy with short multimode fiber probe

    Science.gov (United States)

    Sato, Manabu; Eto, Kai; Goto, Tetsuhiro; Kurotani, Reiko; Abe, Hiroyuki; Nishidate, Izumi

    2018-03-01

    In achieving minimally invasive accessibility to deeply located regions the size of the imaging probes is important. We demonstrated full-field optical coherence tomography (FF-OCM) using an ultrathin forward-imaging short multimode fiber (SMMF) probe of 50 μm core diameter, 125 μm diameter, and 7.4 mm length for optical communications. The axial resolution was measured to be 2.14 μm and the lateral resolution was also evaluated to be below 4.38 μm using a test pattern (TP). The spatial mode and polarization characteristics of SMMF were evaluated. Inserting SMMF to in vivo rat brain, 3D images were measured and 2D information of nerve fibers was obtained. The feasibility of an SMMF as an ultrathin forward-imaging probe in FF-OCM has been demonstrated.

  19. H-L transition caused by irregular probe insertion in the JFT-2M tokamak

    International Nuclear Information System (INIS)

    Hanada, K.; Hasegawa, M.; Shinohara, K.

    1996-01-01

    A pair of probe pins whose lengths differ by 5 mm are inserted into the separatrix of H-mode plasmas. When the long pin is biased positively against the short one, the H-L transition takes place and the current through the resistor making a connection between these pins increases for 10 μs and the potential of the pin increases for 100 μs. The energy dissipated by the resistor during the H-L transition is comparable to the energy of the radial electric field in H-mode plasma. When the long pin is biased negatively, the H-L transition also occurs; however, it takes 1 ms to change the potential of the pin and the plasma returns to H-mode after the extraction of the probe. (author)

  20. Diffusion studies on permeable nitroxyl spin probes through bilayer lipid membranes: A low frequency ESR study

    International Nuclear Information System (INIS)

    Meenakumari, V.; Benial, A. Milton Franklin; Utsumi, Hideo; Ichikawa, Kazuhiro; Yamada, Ken-ichi; Hyodo, Fuminori; Jawahar, A.

    2015-01-01

    Electron spin resonance (ESR) studies were carried out for permeable 2mM 14 N-labeled deutrated 3 Methoxy carbonyl-2,2,5,5-tetramethyl-pyrrolidine-1-oxyl (MC-PROXYL) in pure water and 1mM, 2mM, 3mM, 4mM concentration of 14N-labeled deutrated MC-PROXYL in 400mM concentration of liposomal solution by using a 300 MHz ESR spectrometer. The ESR parameters such as linewidth, hyperfine coupling constant, g-factor, partition parameter and permeability were reported for these samples. The line broadening was observed for the nitroxyl spin probe in the liposomal solution. The line broadening indicates that the high viscous nature of the liposomal solution. The partition parameter and permeability values indicate the maximum diffusion of nitroxyl spin probes in the bilayer lipid membranes at 2 mM concentration of nitroxyl radical. This study illustrates that ESR can be used to differentiate between the intra and extra- membrane water by loading the liposome vesicles with a lipid-permeable nitroxyl spin probe. From the ESR results, the spin probe concentration was optimized as 2mM in liposomal solution for ESR phantom studies/imaging, invivo and invitro experiments

  1. Electrogenerated chemiluminescence biosensing for the detection of prostate PC-3 cancer cells incorporating antibody as capture probe and ruthenium complex-labelled wheat germ agglutinin as signal probe

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Haiying [Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi’an 710062 (China); Department of Chemistry, Yuncheng University, Yuncheng 044300 (China); Li, Zhejian; Shan, Meng; Li, Congcong; Qi, Honglan; Gao, Qiang [Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi’an 710062 (China); Wang, Jinyi [College of Science and College of Veterinary Medicine, Northwest A& F University, Yangling 712100 (China); Zhang, Chengxiao, E-mail: cxzhang@snnu.edu.cn [Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi’an 710062 (China)

    2015-03-10

    Highlights: • A novel biosensor was developed for the detection of prostate cancer cells. • The selectivity of the biosensor was improved using antibody as capture probe. • The biosensor showed the low extremely detection limit of 2.6 × 10{sup 2} cells mL{sup −1}. • The ruthenium complex-labelled WGA can be transported in the cell vesicles. - Abstract: A highly selective and sensitive electrogenerated chemiluminescence (ECL) biosensor for the detection of prostate PC-3 cancer cells was designed using a prostate specific antibody as a capture probe and ruthenium complex-labelled wheat germ agglutinin as a signal probe. The ECL biosensor was fabricated by covalently immobilising the capture probe on a graphene oxide-coated glassy carbon electrode. Target PC-3 cells were selectively captured on the surface of the biosensor, and then, the signal probe was bound with the captured PC-3 cells to form a sandwich. In the presence of tripropylamine, the ECL intensity of the sandwich biosensor was logarithmically directly proportion to the concentration of PC-3 cells over a range from 7.0 × 10{sup 2} to 3.0 × 10{sup 4} cells mL{sup −1}, with a detection limit of 2.6 × 10{sup 2} cells mL{sup −1}. The ECL biosensor was also applied to detect prostate specific antigen with a detection limit of 0.1 ng mL{sup −1}. The high selectivity of the biosensor was demonstrated in comparison with that of a lectin-based biosensor. The strategy developed in this study may be a promising approach and could be extended to the design of ECL biosensors for highly sensitive and selective detection of other cancer-related cells or cancer biomarkers using different probes.

  2. Electrogenerated chemiluminescence biosensing for the detection of prostate PC-3 cancer cells incorporating antibody as capture probe and ruthenium complex-labelled wheat germ agglutinin as signal probe

    International Nuclear Information System (INIS)

    Yang, Haiying; Li, Zhejian; Shan, Meng; Li, Congcong; Qi, Honglan; Gao, Qiang; Wang, Jinyi; Zhang, Chengxiao

    2015-01-01

    Highlights: • A novel biosensor was developed for the detection of prostate cancer cells. • The selectivity of the biosensor was improved using antibody as capture probe. • The biosensor showed the low extremely detection limit of 2.6 × 10 2 cells mL −1 . • The ruthenium complex-labelled WGA can be transported in the cell vesicles. - Abstract: A highly selective and sensitive electrogenerated chemiluminescence (ECL) biosensor for the detection of prostate PC-3 cancer cells was designed using a prostate specific antibody as a capture probe and ruthenium complex-labelled wheat germ agglutinin as a signal probe. The ECL biosensor was fabricated by covalently immobilising the capture probe on a graphene oxide-coated glassy carbon electrode. Target PC-3 cells were selectively captured on the surface of the biosensor, and then, the signal probe was bound with the captured PC-3 cells to form a sandwich. In the presence of tripropylamine, the ECL intensity of the sandwich biosensor was logarithmically directly proportion to the concentration of PC-3 cells over a range from 7.0 × 10 2 to 3.0 × 10 4 cells mL −1 , with a detection limit of 2.6 × 10 2 cells mL −1 . The ECL biosensor was also applied to detect prostate specific antigen with a detection limit of 0.1 ng mL −1 . The high selectivity of the biosensor was demonstrated in comparison with that of a lectin-based biosensor. The strategy developed in this study may be a promising approach and could be extended to the design of ECL biosensors for highly sensitive and selective detection of other cancer-related cells or cancer biomarkers using different probes

  3. Repeating and non-repeating fast radio bursts from binary neutron star mergers

    Science.gov (United States)

    Yamasaki, Shotaro; Totani, Tomonori; Kiuchi, Kenta

    2018-04-01

    Most fast radio bursts (FRB) do not show evidence of repetition, and such non-repeating FRBs may be produced at the time of a merger of binary neutron stars (BNS), provided that the BNS merger rate is close to the high end of the currently possible range. However, the merger environment is polluted by dynamical ejecta, which may prohibit the radio signal from propagating. We examine this by using a general-relativistic simulation of a BNS merger, and show that the ejecta appears about 1 ms after the rotation speed of the merged star becomes the maximum. Therefore there is a time window in which an FRB signal can reach outside, and the short duration of non-repeating FRBs can be explained by screening after ejecta formation. A fraction of BNS mergers may leave a rapidly rotating and stable neutron star, and such objects may be the origin of repeating FRBs like FRB 121102. We show that a merger remnant would appear as a repeating FRB on a time scale of ˜1-10 yr, and expected properties are consistent with the observations of FRB 121102. We construct an FRB rate evolution model that includes these two populations of repeating and non-repeating FRBs from BNS mergers, and show that the detection rate of repeating FRBs relative to non-repeating ones rapidly increases with improving search sensitivity. This may explain why only the repeating FRB 121102 was discovered by the most sensitive FRB search with Arecibo. Several predictions are made, including the appearance of a repeating FRB 1-10 yr after a BNS merger that is localized by gravitational waves and subsequent electromagnetic radiation.

  4. Preparation, quality control and biological evaluation of 99mTc-labelled cationic steroid antibiotic (CSA-13)

    International Nuclear Information System (INIS)

    Roohi, S.; Amir, N.; Mushtaq, A.; Salahuddin, S.M.; Jehangir, M.; Savage, P.B.

    2009-01-01

    Ceragenins (CSAs) are a new class of antimicrobial agents that display broad spectrum antibacterial activity and may find use in the treatment of various infections. A member of this class CSA-13 was labelled with 99m Tc using SnCl 2 .H 2 O as a reducing agent. The labelling efficiency depended on the ligand/reductant ratio, pH and volume of the reaction mixture. The radiochemical purity and stability of 99m Tc-CSA was determined by thin layer chromatography. Biodistribution studies of 99m Tc-CSA were performed in Sprague Dawley rats. Liver and spleen uptake was quite high. A significantly higher accumulation of 99m Tc-CSA was seen at sites of S. aureus infected rats. The results were compared with 99m Tc-Ciprofloxacin. (orig.)

  5. The magnetic-distortion probe: velocimetry in conducting fluids.

    Science.gov (United States)

    Miralles, Sophie; Verhille, Gautier; Plihon, Nicolas; Pinton, Jean-François

    2011-09-01

    A new type of velocimeter, capable of local velocity measurements in conducting fluids, is introduced. The principle of the "magnetic-distortion probe" is based on the measurement of the induced magnetic field by the flow of a conducting fluid in the vicinity of a localized magnetic field. The new velocimeter has no moving parts, and can be enclosed in a sealed cap, easing the implementation in harsh environments, such as liquid metals. The proposed method allows one to probe both the continuous part and fluctuations of the velocity, the temporal and spatial resolution being linked to the actual geometric configuration of the probe. A prototype probe has been tested in a gallinstan pipe flow and in a fully turbulent flow of liquid gallium generated by the counter rotation of two coaxial impellers in a cylinder. The signals have been compared to a reference potential probe and show very good agreement both for time-averaged velocities and turbulent fluctuations. The prototype is shown to detect motion from a few cm s(-1) to a few m s(-1). Moreover, the use of the magnetic-distortion probe with large-scale applied magnetic field is discussed. © 2011 American Institute of Physics

  6. Expression, crystallization and preliminary crystallographic data analysis of filamin A repeats 14–16

    International Nuclear Information System (INIS)

    Aguda, Adeleke Halilu; Sakwe, Amos Malle; Rask, Lars; Robinson, Robert Charles

    2007-01-01

    The crystallization and crystallographic data analysis of filamin repeats 14–16 are reported. Human filamin A is a 280 kDa protein involved in actin-filament cross-linking. It is structurally divided into an actin-binding headpiece (ABD) and a rod domain containing 24 immunoglobulin-like (Ig) repeats. A fragment of human filamin A (Ig repeats 14–16) was cloned and expressed in Escherichia coli and the purified protein was crystallized in 1.6 M ammonium sulfate, 2% PEG 1000 and 100 mM HEPES pH 7.5. The crystals diffracted to 1.95 Å and belong to space group P2 1 2 1 2 1 , with unit-cell parameters a = 50.63, b = 52.10, c = 98.46 Å, α = β = γ = 90°

  7. Strong thermal nonequilibrium in hypersonic CO and CH4 probed by CRDS.

    Science.gov (United States)

    Louviot, M; Suas-David, N; Boudon, V; Georges, R; Rey, M; Kassi, S

    2015-06-07

    A new experimental setup coupling a High Enthalpy Source (HES) reaching 2000 K to a cw-cavity ring-down spectrometer has been developed to investigate rotationally cold hot bands of polyatomic molecules in the [1.5, 1.7] μm region. The rotational and vibrational molecular degrees of freedom are strongly decoupled in the hypersonic expansion produced by the HES and probed by cavity ring-down spectroscopy. Carbon monoxide has been used as a first test molecule to validate the experimental approach. Its expansion in argon led to rotational and vibrational temperatures of 6.7 ± 0.8 K and 2006 ± 476 K, respectively. The tetradecad polyad of methane (1.67 μm) was investigated under similar conditions leading to rotational and vibrational temperatures of 13 ± 5 K and 750 ± 100 K, respectively. The rotationally cold structure of the spectra reveals many hot bands involving highly excited vibrational states of methane.

  8. Neutralisation of interleukin-13 in mice prevents airway pathology caused by chronic exposure to house dust mite.

    Directory of Open Access Journals (Sweden)

    Kate L Tomlinson

    Full Text Available BACKGROUND: Repeated exposure to inhaled allergen can cause airway inflammation, remodeling and dysfunction that manifests as the symptoms of allergic asthma. We have investigated the role of the cytokine interleukin-13 (IL-13 in the generation and persistence of airway cellular inflammation, bronchial remodeling and deterioration in airway function in a model of allergic asthma caused by chronic exposure to the aeroallergen House Dust Mite (HDM. METHODOLOGY/PRINCIPAL FINDINGS: Mice were exposed to HDM via the intranasal route for 4 consecutive days per week for up to 8 consecutive weeks. Mice were treated either prophylactically or therapeutically with a potent neutralising anti-IL-13 monoclonal antibody (mAb administered subcutaneously (s.c.. Airway cellular inflammation was assessed by flow cytometry, peribronchial collagen deposition by histocytochemistry and airway hyperreactivity (AHR by invasive measurement of lung resistance (R(L and dynamic compliance (C(dyn. Both prophylactic and therapeutic treatment with an anti-IL-13 mAb significantly inhibited (P<0.05 the generation and maintenance of chronic HDM-induced airway cellular inflammation, peribronchial collagen deposition, epithelial goblet cell upregulation. AHR to inhaled methacholine was reversed by prophylactic but not therapeutic treatment with anti-IL-13 mAb. Both prophylactic and therapeutic treatment with anti-IL-13 mAb significantly reversed (P<0.05 the increase in baseline R(L and the decrease in baseline C(dyn caused by chronic exposure to inhaled HDM. CONCLUSIONS/SIGNIFICANCE: These data demonstrate that in a model of allergic lung disease driven by chronic exposure to a clinically relevant aeroallergen, IL-13 plays a significant role in the generation and persistence of airway inflammation, remodeling and dysfunction.

  9. 13C nuclear magnetic resonance data of lanosterol derivatives—Profiling the steric topology of the steroid skeleton via substituent effects on its 13C NMR

    Science.gov (United States)

    Dias, Jerry Ray; Gao, Hongwu

    2009-12-01

    The 13C NMR spectra of over 24 tetracyclic triterpenoid derivatives have been structurally analyzed. The 13C NMR chemical shifts allow one to probe the steric topology of the rigid steroid skeleton and inductive effects of its substituents. Use of deuterium labeling in chemical shift assignment and B-ring aromatic terpenoids are also featured.

  10. Detection of Fatigue Cracks at Rivets with Self-Nulling Probe

    Science.gov (United States)

    Wincheski, Buzz; Fulton, Jim; Nath, Shridhar; Namkung, Min

    1994-01-01

    A new eddy current probe developed at NASA Langley Research Center has been used to detect small cracks at rivets in aircraft lap splices [1]. The device has earlier been used to detect isolated fatigue cracks with a minimum detectable flaw size of roughly 1/2 to 1/3 the diameter of the probe [2]. The present work shows that the detectable flaw size for cracks originating at rivets can be greatly improved upon from that of isolated flaws. The use of a rotating probe method combined with spatial filtering has been used to detect 0.18 cm EDM notches, as measured from the rivet shank, with a 1.27 cm diameter probe and to detect flaws buried under the rivet head, down to a length of 0.076 cm, using a 0.32 cm diameter probe. The Self-Nulling Electromagnetic Flaw Detector induces a high density eddy current ring in the sample under test. A ferromagnetic flux focusing lens is incorporated such that in the absence of any inhomogeneities in the material under test only a minimal magnetic field will reach the interior of the probe. A magnetometer (pickup coil) located in the center of the probe therefore registers a null voltage in the absence of material defects. When a fatigue crack or other discontinuity is present in the test article the path of the eddy currents in the material is changed. The magnetic field associated with these eddy currents then enter into the interior of the probe, producing a large output voltage across the pickup coil leads. Further

  11. Anorectal functional outcome after repeated transanal endoscopic microsurgery.

    Science.gov (United States)

    Zhang, Hong-Wei; Han, Xiao-Dong; Wang, Yu; Zhang, Pin; Jin, Zhi-Ming

    2012-10-28

    To evaluate the status of anorectal function after repeated transanal endoscopic microsurgery (TEM). Twenty-one patients undergoing subtotal colectomy with ileorectal anastomosis were included. There were more than 5 large (> 1 cm) polyps in the remaining rectum (range: 6-20 cm from the anal edge). All patients, 19 with villous adenomas and 2 with low-grade adenocarcinomas, underwent TEM with submucosal endoscopic excision at least twice between 2005 and 2011. Anorectal manometry and a questionnaire about incontinence were carried out at week 1 before operation, and at weeks 2 and 3 and 6 mo after the last operation. Anal resting pressure, maximum squeeze pressure, maximum tolerable volume (MTV) and rectoanal inhibitory reflexes (RAIR) were recorded. The integrity and thickness of the internal anal sphincter (IAS) and external anal sphincter (EAS) were also evaluated by endoanal ultrasonography. We determined the physical and mental health status with SF-36 score to assess the effect of multiple TEM on patient quality of life (QoL). All patients answered the questionnaire. Apart from negative RAIR in 4 patients, all of the anorectal manometric values in the 21 patients were normal before operation. Mean anal resting pressure decreased from 38 ± 5 mmHg to 19 ± 3 mmHg (38 ± 5 mmHg vs 19 ± 3 mmHg, P = 0.000) and MTV from 165 ± 19 mL to 60 ± 11 mL (165 ± 19 mL vs 60 ± 11 mL, P = 0.000) at month 3 after surgery. Anal resting pressure and MTV were 37 ± 5 mmHg (38 ± 5 mmHg vs 37 ± 5 mmHg, P = 0.057) and 159 ± 19 mL (165 ± 19 mL vs 159 ± 19 mL, P = 0.071), respectively, at month 6 after TEM. Maximal squeeze pressure decreased from 171 ± 19 mmHg to 62 ± 12 mmHg (171 ± 19 mmHg vs 62 ± 12 mmHg, P = 0.000) at week 2 after operation, and returned to normal values by postoperative month 3 (171 ± 19 vs 166 ± 18, P = 0.051). RAIR were absent in 4 patients preoperatively and in 12 (χ(2) = 4.947, P = 0.026) patients at month 3 after surgery. RAIR was absent only

  12. Factors influencing reliability of liver stiffness measurements using transient elastography (M-probe)—Monocentric experience

    Energy Technology Data Exchange (ETDEWEB)

    Şirli, Roxana, E-mail: roxanasirli@gmail.com; Sporea, Ioan, E-mail: isporea@umft.ro; Bota, Simona, E-mail: bota_simona1982@yahoo.com; Jurchiş, Ana, E-mail: ana.jurchis@yahoo.com

    2013-08-15

    Aim: To retrospectively assess the feasibility of transient elastography (TE) and the factors associated with failed and unreliable liver stiffness measurements (LSMs), in patients with chronic liver diseases. Material and methods: Our retrospective study included 8218 consecutive adult patients with suspected chronic liver diseases. In each patient, LSMs were performed with a FibroScan{sup ®} device (Echosens, France), with the M probe. Failure of TE measurements was defined if no valid measurement was obtained after at least 10 shots and unreliable if fewer than 10 valid shots were obtained, success rate (SR) <60% and/or interquartile range interval/median value (IQR/Med) ≥30%. Results: From the 8218 patients, failed and unreliable LSMs were observed in 29.2% of cases. In univariant analysis, the following risk factors were associated with failed and unreliable measurements: age over 50 years (OR 2.04; 95%CI 1.84–2.26), female gender (OR 1.32; 95%CI 1.20–1.45), BMI > 27.7 kg/m{sup 2} (OR 2.89, 95%CI 2.62–3.19), weight > 77 kg (OR 2.17; 95%CI 1.97–2.40) and height < 162 cm (OR 1.26; 95%CI 1.14–1.40). In multivariate analysis all the factors mentioned above were independently associated with the risk of failed and unreliable measurements. If all the negative predictive factors were present (woman, older than 50 years, with BMI > 27.7 kg/m{sup 2}, heavier than 77 kg and shorter than 162 cm), the rate of failed and unreliable measurements was 58.5%. In obese patients (BMI ≥ 30 kg/m{sup 2}), the rate of failed and unreliable measurements was 49.5%. Conclusion: Failed and unreliable LSMs were observed in 29.1% of patients. Female gender, older age, higher BMI, higher weight and smaller height were significantly associated with failed and unreliable LSMs.

  13. Advances in Probes and Methods for Clinical EPR Oximetry

    Science.gov (United States)

    Hou, Huagang; Khan, Nadeem; Jarvis, Lesley A.; Chen, Eunice Y.; Williams, Benjamin B.; Kuppusamy, Periannan

    2015-01-01

    EPR oximetry, which enables reliable, accurate, and repeated measurements of the partial pressure of oxygen in tissues, provides a unique opportunity to investigate the role of oxygen in the pathogenesis and treatment of several diseases including cancer, stroke, and heart failure. Building on significant advances in the in vivo application of EPR oximetry for small animal models of disease, we are developing suitable probes and instrumentation required for use in human subjects. Our laboratory has established the feasibility of clinical EPR oximetry in cancer patients using India ink, the only material presently approved for clinical use. We now are developing the next generation of probes, which are both superior in terms of oxygen sensitivity and biocompatibility including an excellent safety profile for use in humans. Further advances include the development of implantable oxygen sensors linked to an external coupling loop for measurements of deep-tissue oxygenations at any depth, overcoming the current limitation of 10 mm. This paper presents an overview of recent developments in our ability to make meaningful measurements of oxygen partial pressures in human subjects under clinical settings. PMID:24729217

  14. Fast reciprocating probe system on the EAST superconducting tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, W.; Chang, J. F.; Wan, B. N.; Xu, G. S.; Li, B.; Xu, C. S.; Yan, N.; Wang, L.; Liu, S. C.; Jiang, M.; Liu, P. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei 230031 (China); Xiao, C. J. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, Hefei 230031 (China); Department of Physics and Engineering Physics, Plasma Physics Laboratory, University of Saskatchewan, Saskatoon SK S7N 5E2 (Canada)

    2010-11-15

    A new fast reciprocating probe system (FRPS) has been built and installed on the outer midplane of the EAST tokamak to investigate the profiles of the boundary plasma parameters such as electron density and temperature. The system consists of a two-stage motion drive mechanism: slow motion and fast motion. The fast motion is powered by a servo motor, which drives the probe horizontally up to 50 cm to scan the edge region of the EAST tokamak. The maximum velocity achieved is 2 m/s. High velocity and flexible control of the fast motion are the remarkable features of this FRPS. A specially designed connector installed at the front end of the probe shaft makes it easy to install or replace the probe head on FRPS. During the latest experimental campaign in the spring of 2010, a probe head with seven tips, including two tips for a Mach probe, has been used. An example is given for simultaneous profile measurements of the plasma temperature, plasma density, and the plasma flow velocity.

  15. EGR distribution and fluctuation probe based on CO.sub.2 measurements

    Science.gov (United States)

    Parks, II, James E; Partridge, Jr., William P; Yoo, Ji Hyung

    2015-04-07

    A diagnostic system having a single-port EGR probe and a method for using the same. The system includes a light source, an EGR probe, a detector and a processor. The light source may provide a combined light beam composed of light from a mid-infrared signal source and a mid-infrared reference source. The signal source may be centered at 4.2 .mu.m and the reference source may be centered at 3.8 .mu.m. The EGR probe may be a single-port probe with internal optics and a sampling chamber with two flow cells arranged along the light path in series. The optics may include a lens for focusing the light beam and a mirror for reflecting the light beam received from a pitch optical cable to a catch optical cable. The signal and reference sources are modulated at different frequencies, thereby allowing them to be separated and the signal normalized by the processor.

  16. Readout Distance Enhancement of the Passive Wireless Multi-Parameter Sensing System Using a Repeater Coil

    Directory of Open Access Journals (Sweden)

    Lifeng Wang

    2018-01-01

    Full Text Available A repeater coil is used to extend the detection distance of a passive wireless multi-parameter sensing system. The passive wireless sensing system has the ability of simultaneously monitoring three parameters by using backscatter modulation together with channel multiplexing. Two different repeater coils are designed and fabricated for readout distance enhancement of the sensing system: one is a PCB (printed circuit board repeater coil, and the other is a copper wire repeater coil. Under the conditions of fixed voltage and adjustable voltage, the maximum readout distance of the sensing system with and without a repeater coil is measured. Experimental results show that larger power supply voltage can help further increase the readout distance. The maximum readout distance of the sensing system with a PCB repeater coil has been extended 2.3 times, and the one with a copper wire repeater coil has been extended 3 times. Theoretical analysis and experimental results both indicate that the high Q factor repeater coil can extend the readout distance more. With the copper wire repeater coil as well as a higher power supply voltage, the passive wireless multi-parameter sensing system finally achieves a maximum readout distance of 13.5 cm.

  17. High precision measurement of the micro-imaging system to check repeatability of precision

    International Nuclear Information System (INIS)

    Cheng Lin; Song Li; Ma Chuntao; Luo Hongxin; Wang Jie

    2010-01-01

    The beamlines slits of Shanghai Synchrotron Radiation Facility (SSRF) are required to have a repeatability of better than 1 μm. Before the slits installation, the off-line and/or on-line repeatability measurements must be conducted. A machine vision measuring system based on high resolution CCD and adjustable high magnification lens was used in this regard. A multi-level filtering method was used to treat the imaging data. After image binarization, the imaging noises were depressed effectively by using of algebraic mean filtering, statistics median filtering,and the least square filtering. Using the subtracted image between the images before and after slit movement, an average displacement of slit blades could be obtained, and the repeatability of slit could be measured, with a resolution of 0.3 μm of the measurement system. The experimental results show that this measurement system meets the requirements for non-contact measurements to the repeatability of slits. (authors)

  18. Four-probe measurements with a three-probe scanning tunneling microscope

    International Nuclear Information System (INIS)

    Salomons, Mark; Martins, Bruno V. C.; Zikovsky, Janik; Wolkow, Robert A.

    2014-01-01

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe

  19. Four-probe measurements with a three-probe scanning tunneling microscope

    Energy Technology Data Exchange (ETDEWEB)

    Salomons, Mark [National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta T6G 2M9 (Canada); Martins, Bruno V. C.; Zikovsky, Janik; Wolkow, Robert A., E-mail: rwolkow@ualberta.ca [National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta T6G 2M9 (Canada); Department of Physics, University of Alberta, Edmonton, Alberta T6G 2E1 (Canada)

    2014-04-15

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.

  20. Four-probe measurements with a three-probe scanning tunneling microscope.

    Science.gov (United States)

    Salomons, Mark; Martins, Bruno V C; Zikovsky, Janik; Wolkow, Robert A

    2014-04-01

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.

  1. ACCUMULATION AND METABOLISM OF ARSENIC IN MICE AFTER REPEATED ADMINISTRATION OF ARSENATE

    Science.gov (United States)

    Accumulation and metabolism of arsenic in mice after repeated oral administration of arsenate, Hughes, M. F., Kenyon, E. M., Edwards, B. C., Mitchell, C. T., Del Razo, L. M., and Thomas, D. J. The human carcinogen inorganic arsenic (iAs) is a pervasive environmental ...

  2. Membrane-bound conformation of M13 major coat protein : a structure validation through FRET-derived constraints

    NARCIS (Netherlands)

    Vos, W.L.; Koehorst, R.B.M.; Spruijt, R.B.; Hemminga, M.A.

    2005-01-01

    M13 major coat protein, a 50-amino-acid-long protein, was incorporated into DOPC/DOPG (80/20 molar ratio) unilamellar vesicles. Over 60% of all amino acid residues was replaced with cysteine residues, and the single cysteine mutants were labeled with the fluorescent label I-AEDANS. The coat protein

  3. Investigation of 1.3 μm AlGaInAs multi-quantum wells for electro-absorption modulated laser

    Energy Technology Data Exchange (ETDEWEB)

    Binet, Guillaume [III-V Lab., Route de Nozay, 91461, Marcoussis (France); Institut Jean le Rond d' Alembert, Sorbonne Universites, UPMC Univ. Paris 06, CNRS, UMR 7190, 75005, Paris (France); Decobert, Jean; Lagay, Nadine; Chimot, Nicolas; Kazmierski, Christophe [III-V Lab., Route de Nozay, 91461, Marcoussis (France)

    2016-10-15

    Monolithic photonic integrated circuits (PIC) transmitters using the prefixed optical phase switching concept for BPSK modulation format have been shown promising at 1.55 μm band. These devices could also be crucial for short reach connections and access networks. With this aim, we are studying basic quantum well designs for a laser and an electro-absorption modulator switch to be integrated by selective area growth into PICs at 1.3 μm. Photocurrent measurements and band offset modeling have been performed to determine the MQW stack well-fitted for this application. Broad area laser measurements have also been checked on these structures to verify the material lasing properties. A 6 nm thick well with low barrier seems to be the best trade-off between absorption and shift for 1.3 μm EAM and it also gives good lasing properties. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Identification of tertiary butyl alcohol (TBA)-utilizing organisms in BioGAC reactors using 13C-DNA stable isotope probing.

    Science.gov (United States)

    Aslett, Denise; Haas, Joseph; Hyman, Michael

    2011-09-01

    Biodegradation of the gasoline oxygenates methyl tertiary-butyl ether (MTBE) and ethyl tertiary-butyl ether (ETBE) can cause tertiary butyl alcohol (TBA) to accumulate in gasoline-impacted environments. One remediation option for TBA-contaminated groundwater involves oxygenated granulated activated carbon (GAC) reactors that have been self-inoculated by indigenous TBA-degrading microorganisms in ground water extracted from contaminated aquifers. Identification of these organisms is important for understanding the range of TBA-metabolizing organisms in nature and for determining whether self-inoculation of similar reactors is likely to occur at other sites. In this study (13)C-DNA-stable isotope probing (SIP) was used to identify TBA-utilizing organisms in samples of self-inoculated BioGAC reactors operated at sites in New York and California. Based on 16S rRNA nucleotide sequences, all TBA-utilizing organisms identified were members of the Burkholderiales order of the β-proteobacteria. Organisms similar to Cupriavidus and Methylibium were observed in both reactor samples while organisms similar to Polaromonas and Rhodoferax were unique to the reactor sample from New York. Organisms similar to Hydrogenophaga and Paucibacter strains were only detected in the reactor sample from California. We also analyzed our samples for the presence of several genes previously implicated in TBA oxidation by pure cultures of bacteria. Genes Mpe_B0532, B0541, B0555, and B0561 were all detected in (13)C-metagenomic DNA from both reactors and deduced amino acid sequences suggested these genes all encode highly conserved enzymes. One gene (Mpe_B0555) encodes a putative phthalate dioxygenase-like enzyme that may be particularly appropriate for determining the potential for TBA oxidation in contaminated environmental samples.

  5. Versatile de novo enzyme activity in capsid proteins from an engineered M13 bacteriophage library.

    Science.gov (United States)

    Casey, John P; Barbero, Roberto J; Heldman, Nimrod; Belcher, Angela M

    2014-11-26

    Biocatalysis has grown rapidly in recent decades as a solution to the evolving demands of industrial chemical processes. Mounting environmental pressures and shifting supply chains underscore the need for novel chemical activities, while rapid biotechnological progress has greatly increased the utility of enzymatic methods. Enzymes, though capable of high catalytic efficiency and remarkable reaction selectivity, still suffer from relative instability, high costs of scaling, and functional inflexibility. Herein, we developed a biochemical platform for engineering de novo semisynthetic enzymes, functionally modular and widely stable, based on the M13 bacteriophage. The hydrolytic bacteriophage described in this paper catalyzes a range of carboxylic esters, is active from 25 to 80 °C, and demonstrates greater efficiency in DMSO than in water. The platform complements biocatalysts with characteristics of heterogeneous catalysis, yielding high-surface area, thermostable biochemical structures readily adaptable to reactions in myriad solvents. As the viral structure ensures semisynthetic enzymes remain linked to the genetic sequences responsible for catalysis, future work will tailor the biocatalysts to high-demand synthetic processes by evolving new activities, utilizing high-throughput screening technology and harnessing M13's multifunctionality.

  6. Rare top decay t{yields}c anti ll as a probe of new physics

    Energy Technology Data Exchange (ETDEWEB)

    Diaz-Cruz, J.L.; Diaz-Furlong, A. [BUAP, Cuerpo Academico de Particulas, Campos y Relatividad Facultad de Ciencias Fisico-Matematicas, Apdo. Postal 1364, Puebla, Pue. (Mexico); Gaitan-Lozano, R.; Montes de Oca Y, J.H. [UNAM, Departamento de Fisica, FES-Cuautitlan, Estado de Mexico (Mexico)

    2012-08-15

    The rare top decay t{yields}c anti ll, which involves flavor violation, is studied as a possible probe of new physics. This decay is analyzed with one of the simplest Standard Model extensions with additional gauge symmetry formalism. The considered extension is the Left-Right Symmetric Model, including a new neutral gauge boson Z' that allows one to obtain the decay at tree level through Flavor-Changing Neutral Currents (FCNC) couplings. The neutral gauge boson couplings are considered diagonal but family non-universal in order to induce these FCNC. We find BR(t{yields}c anti ll){proportional_to}10{sup -13} for the range 1 TeV{<=}M{sub Z'}{<=}3 TeV. (orig.)

  7. Repeated cue exposure effects on subjective and physiological indices of chocolate craving

    NARCIS (Netherlands)

    van Gucht, D.; Vansteenwegen, D.; Beckers, T.; Hermans, D.; Baeyens, F.; Van den Bergh, O.

    2008-01-01

    The aim of this study is to investigate the effects of repeated unreinforced exposure to chocolate cues in persons reporting chocolate craving. Participants in the experimental group (n ¼ 40) received 10 consecutive brief exposures to chocolate cues in each of two sessions, separated by 1-3 days.

  8. Probe code: a set of programs for processing and analysis of the left ventricular function - User's manual

    International Nuclear Information System (INIS)

    Piva, R.M.V.

    1987-01-01

    The User's Manual of the Probe Code is an addendum to the M.Sc. thesis entitled A Microcomputer System of Nuclear Probe to Check the Left Ventricular Function. The Probe Code is a software which was developed for processing and off-line analysis curves from the Left Ventricular Function, that were obtained in vivo. These curves are produced by means of an external scintigraph probe, which was collimated and put on the left ventricule, after a venous inoculation of Tc-99 m. (author)

  9. Effects of an In-season Plyometric Training Program on Repeated Change of Direction and Sprint Performance in the Junior Soccer Player.

    Science.gov (United States)

    Hammami, Mehréz; Negra, Yassine; Aouadi, Ridha; Shephard, Roy J; Chelly, Mohamed Souhaiel

    2016-12-01

    Hammami, M, Negra, Y, Aouadi, R, Shephard, RJ, and Chelly, MS. Effects of an in-season plyometric training program on repeated change of direction and sprint performance in the junior soccer player. J Strength Cond Res 30(12): 3312-3320, 2016-We aimed to determine the gains in explosive movements of male junior soccer players induced by incorporating an 8-week plyometric training program (PTP) into a standard soccer conditioning regimen 5 months after the beginning of the competitive season. Our hypothesis was that PTP would enhance explosive movements, and thus sprint running, repeated shuttle sprint ability (RSSA), agility and the ability to make repeated changes of direction (RCOD). A group of junior soccer players were randomly divided into 2 groups: an experimental group (E, n = 15, age 15.7 ± 0.2 years) and a control group (C, n = 13, age 15.8 ± 0.2 years). The participants in E and C performed training exercises and matches together, but for an 8-week period in the latter part of the season, the experimental group replaced a part of the normal regimen (the tactical session) by a biweekly course of PTP (hurdle and drop jumps). Two familiarization sessions were held 2 weeks before definitive testing. The ability of the players was assessed by 3 agility tests (a sprint test with 180° turns, a 9-3-6-3-9 m sprint with backward and forward running, and a four 5-m sprint test with turns); 2 repeated sprint tests (RSSA and RCOD); and running times over 5-, 10-, 20-, 30-, and 40-m distances. Participants in E showed gains relative to C in sprint times (p ≤ 0.05 for 5, 10, and 20 m), and 2 of 3 the RCOD parameters (RCOD best, p ≤ 0.001; RCOD total, p ≤ 0.05). However, with the pattern of plyometric training that we adopted, and perhaps because participants were in good initial physical condition, the agility and RSSA test scores remained unchanged. Nevertheless, we conclude that our PTP can be commended to junior soccer players as a means of improving

  10. High-bandwidth piezoresistive force probes with integrated thermal actuation

    International Nuclear Information System (INIS)

    Doll, Joseph C; Pruitt, Beth L

    2012-01-01

    We present high-speed force probes with on-chip actuation and sensing for the measurement of pN-scale forces at the microsecond timescale. We achieve a high resonant frequency in water (1–100 kHz) with requisite low spring constants (0.3–40 pN nm −1 ) and low integrated force noise (1–100 pN) by targeting probe dimensions on the order of 300 nm thick, 1–2 μm wide and 30–200 μm long. Forces are measured using silicon piezoresistors, while the probes are actuated thermally with an aluminum unimorph and silicon heater. The piezoresistive sensors are designed using the open-source numerical optimization code that incorporates constraints on operating temperature. Parylene passivation enables operation in ionic media and we demonstrate simultaneous actuation and sensing. The improved design and fabrication techniques that we describe enable a 10–20-fold improvement in force resolution or measurement bandwidth over prior piezoresistive cantilevers of comparable thickness. (paper)

  11. High bandwidth piezoresistive force probes with integrated thermal actuation

    Science.gov (United States)

    Doll, Joseph C.; Pruitt, Beth L.

    2012-01-01

    We present high-speed force probes with on-chip actuation and sensing for the measurement of pN-scale forces at the microsecond time scale. We achieve a high resonant frequency in water (1–100 kHz) with requisite low spring constants (0.3–40 pN/nm) and low integrated force noise (1–100 pN) by targeting probe dimensions on the order of 300 nm thick, 1–2 μm wide and 30–200 μm long. Forces are measured using silicon piezoresistors while the probes are actuated thermally with an aluminum unimorph and silicon heater. The piezoresistive sensors are designed using open source numerical optimization code that incorporates constraints on operating temperature. Parylene passivation enables operation in ionic media and we demonstrate simultaneous actuation and sensing. The improved design and fabrication techniques that we describe enable a 10–20 fold improvement in force resolution or measurement bandwidth over prior piezoresistive cantilevers of comparable thickness. PMID:23175616

  12. Labeled estrogens as mammary tumor probes

    International Nuclear Information System (INIS)

    Feenstra, A.

    1981-01-01

    In this thesis estrogens labeled with a gamma or positron emitting nuclide, called estrogen-receptor binding radiopharmaceuticals are investigated as mammary tumour probes. The requirements for estrogen-receptor binding radiopharmaceuticals are formulated and the literature on estrogens labeled for this purpose is reviewed. The potential of mercury-197/197m and of carbon-11 as label for estrogen-receptor binding radiopharmaceuticals is investigated. The synthesis of 197 Hg-labeled 4-mercury-estradiol and 2-mercury-estradiol and their properties in vitro and in vivo are described. It appears that though basically carbon-11 labeled compounds are very promising as mammary tumour probes, their achievable specific activity has to be increased. (Auth.)

  13. Exciton-controlled fluorescence: application to hybridization-sensitive fluorescent DNA probe.

    Science.gov (United States)

    Okamoto, Akimitsu; Ikeda, Shuji; Kubota, Takeshi; Yuki, Mizue; Yanagisawa, Hiroyuki

    2009-01-01

    A hybridization-sensitive fluorescent probe has been designed for nucleic acid detection, using the concept of fluorescence quenching caused by the intramolecular excitonic interaction of fluorescence dyes. We synthesized a doubly thiazole orange-labeled nucleotide showing high fluorescence intensity for a hybrid with the target nucleic acid and effective quenching for the single-stranded state. This exciton-controlled fluorescent probe was applied to living HeLa cells using microinjection to visualize intracellular mRNA localization. Immediately after injection of the probe into the cell, fluorescence was observed from the probe hybridizing with the target RNA. This fluorescence rapidly decreased upon addition of a competitor DNA. Multicoloring of this probe resulted in the simple simultaneous detection of plural target nucleic acid sequences. This probe realized a large, rapid, reversible change in fluorescence intensity in sensitive response to the amount of target nucleic acid, and facilitated spatiotemporal monitoring of the behavior of intracellular RNA.

  14. Endoscopic optical coherence tomography with a focus-adjustable probe.

    Science.gov (United States)

    Liao, Wenchao; Chen, Tianyuan; Wang, Chengming; Zhang, Wenxin; Peng, Zhangkai; Zhang, Xiao; Ai, Shengnan; Fu, Deyong; Zhou, Tieying; Xue, Ping

    2017-10-15

    We present a focus-adjustable endoscopic probe for optical coherence tomography (OCT), which is able to acquire images with different focal planes and overcome depth-of-focus limitations by image fusing. The use of a two-way shape-memory-alloy spring enables the probe to adjust working distance over 1.5 mm, providing a large scanning range with high resolution and no sensitivity loss. Equipped with a homemade hollow-core ultrasonic motor, the probe is capable of performing an unobstructed 360 deg field-of-view distal scanning. Both the axial resolution and the best lateral resolution are ∼4  μm, with a sensitivity of 100.3 dB. Spectral-domain OCT imaging of phantom and biological tissues with the probe is also demonstrated.

  15. (PO_4)"3"− polyanions doped LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2: An ultrafast-rate, long-life and high-voltage cathode material for Li-ion rechargeable batteries

    International Nuclear Information System (INIS)

    Cong, Lina; Zhao, Qin; Wang, Zhao; Zhang, Yuhang; Wu, Xinglong; Zhang, Jingping; Wang, Rongshun; Xie, Haiming; Sun, Liqun

    2016-01-01

    Highlights: • LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 layered structure is doped with (PO_4)"3"− polyanions. • Results confirm that (PO_4)"3"− influences MO_6 octahedral environment in LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 lattice. • Charge–discharge properties are investigated under high voltage battery operation. • Cycling and rate performance of the doped materials is markedly enhanced. • Pre-cycling treatment inhibits microcracks at the grain boundaries at 4.7–2.8 V. - Abstract: Layered compounds LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 have recently received much attention as they have been regarded as a promising cathode materials for industrial application. However, its fast energy density decay and poor rate performance which originate from structure disruption especially at high rate and high cut-off voltage limit its large-scale application. Here, a novel designed concept and facile method were firstly used to fabricate (PO_4)"3"− polyanions doped layered LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 (LNMC-(PO_4) _0_._0_1_5-O_1_._9_4) structure, which could offer more stable high-voltage cycling performance and high rate capability. We attribute this improved performance to the robust P_t_e_t-O covalence, which will stabilize the oxygen close-packed structure during repeated cycling. Moreover, our stepwise pre-cycling treatments could effectively restrain the formation of micro-cracks and non-crystallization defects, and significantly improve cyclic durability with high charge voltage of 4.7V. The LNMC-(PO_4) _0_._0_1_5-O_1_._9_4 electrode can still delivers capacity retention of 81% after 200 cycles at a current density of 300mA g"−"1. The preliminary results reported here manifest that this novel-designed LNMC-(PO_4) _0_._0_1_5-O_1_._9_4 material represents an attractive alternative to ultrafast-rate, long-life and high-voltage electrode material for lithium ion batteries.

  16. Radiation-induced base substitution mutagenesis in single-stranded DNA phage M13

    International Nuclear Information System (INIS)

    Brandenburger, A.; Godson, G.N.; Glickman, B.W.; Sluis, C.A. van

    1981-01-01

    To elucidate the relative contributions of targeted and untargeted mutations to γ and UV radiation mutagenesis, the DNA sequences of 174 M13 revertant phages isolated from stocks of irradiated or unirradiated amber mutants grown in irradiated (SOS-induced) or unirradiated (non-induced) host bacteria, have been determined. Differences in the spectra of base change mutations induced in the various conditions were apparent, but no obvious specificity of mutagenesis was detected. In particular, under the present conditions, pyrimidine dimers did not seem to be the principal sites of UV-induced base substitution mutagenesis, suggesting that such mutagenesis occurs at the sites of lesions other than pyrimidine dimers, or is untargeted. (U.K.)

  17. A Unified Model for Repeating and Non-repeating Fast Radio Bursts

    International Nuclear Information System (INIS)

    Bagchi, Manjari

    2017-01-01

    The model that fast radio bursts (FRBs) are caused by plunges of asteroids onto neutron stars can explain both repeating and non-repeating bursts. If a neutron star passes through an asteroid belt around another star, there would be a series of bursts caused by a series of asteroid impacts. Moreover, the neutron star would cross the same belt repetitively if it were in a binary with the star hosting the asteroid belt, leading to a repeated series of bursts. I explore the properties of neutron star binaries that could lead to the only known repeating FRB so far (FRB121102). In this model, the next two epochs of bursts are expected around 2017 February 27 and 2017 December 18. On the other hand, if the asteroid belt is located around the neutron star itself, then a chance fall of an asteroid from that belt onto the neutron star would lead to a non-repeating burst. Even a neutron star grazing an asteroid belt can lead to a non-repeating burst caused by just one asteroid plunge during the grazing. This is possible even when the neutron star is in a binary with the asteroid-hosting star, if the belt and the neutron star orbit are non-coplanar.

  18. A Unified Model for Repeating and Non-repeating Fast Radio Bursts

    Energy Technology Data Exchange (ETDEWEB)

    Bagchi, Manjari, E-mail: manjari@imsc.res.in [The Institute of Mathematical Sciences (IMSc-HBNI), 4th Cross Road, CIT Campus, Taramani, Chennai 600113 (India)

    2017-04-01

    The model that fast radio bursts (FRBs) are caused by plunges of asteroids onto neutron stars can explain both repeating and non-repeating bursts. If a neutron star passes through an asteroid belt around another star, there would be a series of bursts caused by a series of asteroid impacts. Moreover, the neutron star would cross the same belt repetitively if it were in a binary with the star hosting the asteroid belt, leading to a repeated series of bursts. I explore the properties of neutron star binaries that could lead to the only known repeating FRB so far (FRB121102). In this model, the next two epochs of bursts are expected around 2017 February 27 and 2017 December 18. On the other hand, if the asteroid belt is located around the neutron star itself, then a chance fall of an asteroid from that belt onto the neutron star would lead to a non-repeating burst. Even a neutron star grazing an asteroid belt can lead to a non-repeating burst caused by just one asteroid plunge during the grazing. This is possible even when the neutron star is in a binary with the asteroid-hosting star, if the belt and the neutron star orbit are non-coplanar.

  19. In Silico-Based Repositioning of Phosphinothricin as a Novel Technetium-99m Imaging Probe with Potential Anti-Cancer Activity

    Directory of Open Access Journals (Sweden)

    Tamer M. Sakr

    2018-02-01

    Full Text Available l-Phosphinothricin (glufosinate or 2-amino-4-((hydroxy(methyl phosphinyl butyric acid ammonium salt (AHPB, which is a structural analog of glutamate, is a recognized herbicide that acts on weeds through inhibition of glutamine synthetase. Due to the structural similarity between phosphinothricin and some bisphosphonates (BPs, this study focuses on investigating the possibility of repurposing phosphinothricin as a bisphosphonate analogue, particularly in two medicine-related activities: image probing and as an anti-cancer drug. As BP is a competitive inhibitor of human farnesyl pyrophosphate synthase (HFPPS, in silico molecular docking and dynamic simulations studies were established to evaluate the binding and stability of phosphinothricin with HFPPS, while the results showed good binding and stability in the active site of the enzyme in relation to alendronate. For the purpose of inspecting bone-tissue accumulation of phosphinothricin, a technetium (99mTc–phosphinothricin complex was developed and its stability and tissue distribution were scrutinized. The radioactive complex showed rapid, high and sustained uptake into bone tissues. Finally, the cytotoxic activity of phosphinothricin was tested against breast and lung cancer cells, with the results indicating cytotoxic activity in relation to alendronate. All the above results provide support for the use of phosphinothricin as a potential anti-cancer drug and of its technetium complex as an imaging probe.

  20. Repeatability of Cryogenic Multilayer Insulation

    Science.gov (United States)

    Johnson, W. L.; Vanderlaan, M.; Wood, J. J.; Rhys, N. O.; Guo, W.; Van Sciver, S.; Chato, D. J.

    2017-12-01

    Due to the variety of requirements across aerospace platforms, and one off projects, the repeatability of cryogenic multilayer insulation (MLI) has never been fully established. The objective of this test program is to provide a more basic understanding of the thermal performance repeatability of MLI systems that are applicable to large scale tanks. There are several different types of repeatability that can be accounted for: these include repeatability between identical blankets, repeatability of installation of the same blanket, and repeatability of a test apparatus. The focus of the work in this report is on the first two types of repeatability. Statistically, repeatability can mean many different things. In simplest form, it refers to the range of performance that a population exhibits and the average of the population. However, as more and more identical components are made (i.e. the population of concern grows), the simple range morphs into a standard deviation from an average performance. Initial repeatability testing on MLI blankets has been completed at Florida State University. Repeatability of five Glenn Research Center (GRC) provided coupons with 25 layers was shown to be +/- 8.4% whereas repeatability of repeatedly installing a single coupon was shown to be +/- 8.0%. A second group of 10 coupons has been fabricated by Yetispace and tested by Florida State University, the repeatability between coupons has been shown to be +/- 15-25%. Based on detailed statistical analysis, the data has been shown to be statistically significant.

  1. Fast reciprocating probe system on the HL-2A tokamak

    International Nuclear Information System (INIS)

    Yan Longwen; Hong Wenyu; Qian Jun; Luo Cuiwen; Pan Li

    2005-01-01

    A reciprocating probe system has been installed at the midplane of the HL-2A tokamak. The probe is used to measure plasma edge density, temperature, floating potential, and corresponding fluctuation profiles with 8 cm scan from the scrape-off layer to the plasma boundary. The reciprocating probe can move at a speed of 1 m/s. A digital grating displacement measurement system that can provide a high displacement resolution of 0.04 mm is applied to the reciprocating probe system for the first time. A port located behind the vacuum isolation valve is designed for viewing and the exchange of the probe head. Different probe heads can be used to satisfy different experimental requirements. The first probe head had four graphite measurement tips. For high frequency response, no isolation amplifier is used in the electric circuit of the probe measurement. A personal computer via an analog-to-digital digitizer card acquires probe system data, which are sent to a data server by optical fiber after a discharge. All data are sent to the centralized data management system of the HL-2A. In this article we presented the edge temperature and density profiles for the limiter and divertor configurations of a selected plasma discharge

  2. High-resolution YAC-cosmid-STS map of human chromosome 13.

    Science.gov (United States)

    Cayanis, E; Russo, J J; Kalachikov, S; Ye, X; Park, S H; Sunjevaric, I; Bonaldo, M F; Lawton, L; Venkatraj, V S; Schon, E; Soares, M B; Rothstein, R; Warburton, D; Edelman, I S; Zhang, P; Efstratiadis, A; Fischer, S G

    1998-01-01

    We have assembled a high-resolution physical map of human chromosome 13 DNA (approximately 114 Mb) from hybridization, PCR, and FISH mapping data using a specifically designed set of computer programs. Although the mapping of 13p is limited, 13q (approximately 98 Mb) is covered by an almost continuous contig of 736 YACs aligned to 597 contigs of cosmids. Of a total of 10,789 cosmids initially selected from a chromosome 13-specific cosmid library (16,896 colonies) using inter-Alu PCR probes from the YACs and probes for markers mapped to chromosome 13, 511 were assembled in contigs that were established from cross-hybridization relationships between the cosmids. The 13q YAC-cosmid map was annotated with 655 sequence tagged sites (STSs) with an average spacing of 1 STS per 150 kb. This set of STSs, each identified by a D number and cytogenetic location, includes database markers (198), expressed sequence tags (93), and STSs generated by sequencing of the ends of cosmid inserts (364). Additional annotation has been provided by positioning 197 cosmids mapped by FISH on 13q. The final (comprehensive) map, a list of STS primers, and raw data used in map assembly are available at our Web site (genome1.ccc.columbia.edu/ approximately genome/) and can serve as a resource to facilitate accurate localization of additional markers, provide substrates for sequencing, and assist in the discovery of chromosome 13 genes associated with hereditary diseases.

  3. Synthesis of a Cu2+-Selective Probe Derived from Rhodamine and Its Application in Cell Imaging

    Directory of Open Access Journals (Sweden)

    Chunwei Yu

    2014-11-01

    Full Text Available A new fluorescent probe P based on rhodamine for Cu2+ was synthesized and characterized. The new probe P showed high selectivity to Cu2+ over other tested metal ions. With optimal conditions, the proposed probe P worked in a wide linear range of 1.0 × 10−6–1.0 × 10−5 M with a detection limit of 3.3 × 10−7 M Cu2+ in ethanol-water solution (9:1, v:v, 20 mM HEPES, pH 7.0. Furthermore, it has been used for imaging of Cu2+ in living cells with satisfying results.

  4. Mobile Game Probes

    DEFF Research Database (Denmark)

    Borup Lynggaard, Aviaja

    2006-01-01

    This paper will examine how probes can be useful for game designers in the preliminary phases of a design process. The work is based upon a case study concerning pervasive mobile phone games where Mobile Game Probes have emerged from the project. The new probes are aimed towards a specific target...... group and the goal is to specify the probes so they will cover the most relevant areas for our project. The Mobile Game Probes generated many interesting results and new issues occurred, since the probes came to be dynamic and favorable for the process in new ways....

  5. Conformation of bovine submaxillary mucin layers on hydrophobic surface as studied by biomolecular probes

    DEFF Research Database (Denmark)

    Pakkanen, Kirsi I.; Madsen, Jan Busk; Lee, Seunghwan

    2015-01-01

    In the present study, the conformational changes of bovine submaxillary mucin (BSM) adsorbed on a hydrophobic surface (polystyrene (PS)) as a function of concentration in bulk solution (up to 2mg/mL) have been investigated with biomolecular probe-based approaches, including bicinchoninic acid (BCA),enzyme-linkedimmunosorbentassay(EIA...... solution. Adsorbed masses of BSM onto hydrophobic surface, as probe by BCA, showed a continuously increasing trend up to 2mg/mL. But, the signals from EIA and ELLA, which probe the concentration of available unglycosylatedC-terminals and the central glycosylated regions, respectively, showed complicated...

  6. Influence of access hole parameters on neutron moisture probe readings

    International Nuclear Information System (INIS)

    Abeele, W.V.

    1979-10-01

    Computing soil moisture content with a neutron probe requires use of a calibration curve that considers the thermal neutron capture cross section of the hole liner, as well as the hole diameter. The influence of steel, polyvinyl chloride, and aluminum casings that fit 0.051- to 0.102-m hole diameters was determined by comparison with neutron probe readings in uncased holes of corresponding diameters. Eccentricity of probe location was considered a potentially significant variable. The experiment was run in disturbed Bandelier tuff with an average dry density of 1.35g . cm -3 and moisture content of 3.8 to 26.7% by volume. The casing material and hole diameter influenced the probe readings significantly, whereas eccentric location of the probe did not. Regression analyses showed an almost perfect inverse linear correlation between hole diameter and count rate

  7. PET-Probe: Evaluation of Technical Performance and Clinical Utility of a Handheld High-Energy Gamma Probe in Oncologic Surgery.

    Science.gov (United States)

    Gulec, Seza A; Daghighian, Farhad; Essner, Richard

    2016-12-01

    Positron emission tomography (PET) has become an invaluable part of patient evaluation in surgical oncology. PET is less than optimal for detecting lesions PET-positive lesions can be challenging as a result of difficulties in surgical exposure. We undertook this investigation to assess the utility of a handheld high-energy gamma probe (PET-Probe) for intraoperative identification of 18 F-deoxyglucose (FDG)-avid tumors. Forty patients underwent a diagnostic whole-body FDG-PET scan for consideration for surgical exploration and resection. Before surgery, all patients received an intravenous injection of 7 to 10 mCi of FDG. At surgery, the PET-Probe was used to determine absolute counts per second at the known tumor site(s) demonstrated by whole-body PET and at adjacent normal tissue (at least 4 cm away from tumor-bearing sites). Tumor-to-background ratios were calculated. Thirty-two patients (80%) underwent PET-Probe-guided surgery with therapeutic intent in a recurrent or metastatic disease setting. Eight patients underwent surgery for diagnostic exploration. Anatomical locations of the PET-identified lesions were neck and supraclavicular (n = 8), axilla (n = 5), groin and deep iliac (n = 4), trunk and extremity soft tissue (n = 3), abdominal and retroperitoneal (n = 19), and lung (n = 2). PET-Probe detected all PET-positive lesions. The PET-Probe was instrumental in localization of lesions in 15 patients that were not immediately apparent by surgical exploration. The PET-Probe identified all lesions demonstrated by PET scanning and, in selected cases, was useful in localizing FDG-avid disease not seen with conventional PET scanning.

  8. Saline-enhanced hepatic radiofrequency ablation using a perfused-cooled electrode: comparison of dual probe bipolar mode with monopolar and single probe bipolar modes

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Joon Koo; Kim, Se Hyung; Lee, Jae Young; Kim, Dae Jin; Lee, Min Woo; Cho, Gyung Goo; Han, Chang Jin; Choi, Byung Ihn

    2004-01-01

    To determine whether saline-enhanced dual probe bipolar radiofrequency ablation (RFA) using perfused-cooled electrodes shows better in-vitro efficiency than monopolar or single probe bipolar RFA in creating larger coagulation necrosis. RF was applied to excised bovine livers in both bipolar and monopolar modes using a 200W generator (CC-3; Radionics) and the perfused-cooled electrodes for 10 mins. After placing single or double perfused-cooled electrodes in the explanted liver, 30 ablation zones were created at three different regimens: group A; saline-enhanced monopolar RFA, group B; saline-enhanced single probe bipolar RFA, and group C; saline-enhanced dual probe bipolar RFA. During RFA, we measured the tissue temperature at 15mm from the electrode. The dimensions of the ablation zones and changes in the impedance currents and liver temperature during RFA were then compared between the groups. The mean current values were higher for monopolar mode (group A) than for the bipolar modes (group B and C): 1550 ± 25 mA in group A, 764 ±189 mA in group B and 819 ± 98 mA in group C(ρ 3 in group A, 23.7 ±3.8 cm 3 in group B, and 34.2 ± 5.1 cm 3 in group C(ρ 0.05). The temperature at 15 mm from the electrode was higher in group C than in the other groups: 70 ± 18 .deg. C in group A, 59 ± 23 .deg. C in group B and 96 ± 16 .deg. C in group C (ρ < 0.05). Saline-enhanced bipolar RFA using dual perfused-cooled electrodes increases the dimension of the ablation zone more efficiently than monopolar RFA or single probe bipolar RFA

  9. Traversing probe system

    Science.gov (United States)

    Mashburn, Douglas N.; Stevens, Richard H.; Woodall, Harold C.

    1977-01-01

    This invention comprises a rotatable annular probe-positioner which carries at least one radially disposed sensing probe, such as a Pitot tube having a right-angled tip. The positioner can be coaxially and rotatably mounted within a compressor casing or the like and then actuated to orient the sensing probe as required to make measurements at selected stations in the annulus between the positioner and compressor casing. The positioner can be actuated to (a) selectively move the probe along its own axis, (b) adjust the yaw angle of the right-angled probe tip, and (c) revolve the probe about the axis common to the positioner and casing. A cam plate engages a cam-follower portion of the probe and normally rotates with the positioner. The positioner includes a first-motor-driven ring gear which effects slidable movement of the probe by rotating the positioner at a time when an external pneumatic cylinder is actuated to engage the cam plate and hold it stationary. When the pneumatic cylinder is not actuated, this ring gear can be driven to revolve the positioner and thus the probe to a desired circumferential location about the above-mentioned common axis. A second motor-driven ring gear included in the positioner can be driven to rotate the probe about its axis, thus adjusting the yaw angle of the probe tip. The positioner can be used in highly corrosive atmosphere, such as gaseous uranium hexafluoride.

  10. Traversing probe system

    International Nuclear Information System (INIS)

    Mashburn, D.N.; Stevens, R.H.; Woodall, H.C.

    1977-01-01

    This invention comprises a rotatable annular probe-positioner which carries at least one radially disposed sensing probe, such as a Pitot tube having a right-angled tip. The positioner can be coaxially and rotatably mounted within a compressor casing or the like and then actuated to orient the sensing probe as required to make measurements at selected stations in the annulus between the positioner and compressor casing. The positioner can be actuated to (a) selectively move the probe along its own axis, (b) adjust the yaw angle of the right-angled probe tip, and (c) revolve the probe about the axis common to the positioner and casing. A cam plate engages a cam-follower portion of the probe and normally rotates with the positioner. The positioner includes a first-motor-driven ring gear which effects slidable movement of the probe by rotating the positioner at a time when an external pneumatic cylinder is actuated to engage the cam plate and hold it stationary. When the pneumatic cylinder is not actuated, this ring gear can be driven to revolve the positioner and thus the probe to a desired circumferential location about the above-mentioned common axis. A second motor-driven ring gear included in the positioner can be driven to rotate the probe about its axis, thus adjusting the yaw angle of the probe tip. The positioner can be used in highly corrosive atmosphere, such as gaseous uranium hexafluoride. 10 claims, 6 figures

  11. Influence of probe geometry on the response of an electrostatic probe

    DEFF Research Database (Denmark)

    Johansson, Torben; Crichton, George C; McAllister, Iain Wilson

    1999-01-01

    The response of an electrostatic probe is examined with reference to the probe geometry. The study involves the evaluation of the probe lambda function, from which response-related characteristic parameters can be derived. These parameters enable the probe detection sensitivity Se and spatial...

  12. In vivo Raman measurement of levofloxacin lactate in blood using a nanoparticle-coated optical fiber probe

    Science.gov (United States)

    Liu, Shupeng; Rong, Ming; Zhang, Heng; Chen, Na; Pang, Fufei; Chen, Zhenyi; Wang, Tingyun; Yan, Jianshe

    2016-01-01

    Monitoring drug concentrations in vivo is very useful for adjusting a drug dosage during treatment and for drug research. Specifically, cutting-edge “on-line” drug research relies on knowing how drugs are metabolized or how they interact with the blood in real-time. Thus, this study explored performing in vivo Raman measurements of the model drug levofloxacin lactate in the blood using a nanoparticle-coated optical fiber probe (optical fiber nano-probe). The results show that we were able to measure real-time changes in the blood concentration of levofloxacin lactate, suggesting that this technique could be helpful for performing drug analyses and drug monitoring in a clinical setting without repeatedly withdrawing blood from patients. PMID:27231590

  13. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Directory of Open Access Journals (Sweden)

    Aysun Şanal Doğan

    2018-04-01

    Full Text Available Objectives: The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Materials and Methods: Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy. Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Results: Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198 and gender (M/F: 4/29 vs. 8/32, p=0.366. Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90. Conclusion: The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  14. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    Science.gov (United States)

    Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay

    2018-04-01

    The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  15. Deployment Repeatability

    Science.gov (United States)

    2016-04-01

    evaluating the deployment repeatability builds upon the testing or analysis of deployment kinematics (Chapter 6) and adds repetition. Introduction...material yield or failure during a test. For the purposes of this chapter, zero shift will refer to permanent changes in the structure, while reversible ...the content of other chapters in this book: Gravity Compensation (Chapter 4) and Deployment Kinematics and Dynamics (Chapter 6). Repeating the

  16. Polarimetry of SN 2014J in M82 as a Probe of Its Dusty Environment

    Science.gov (United States)

    Wang, Lifan

    2014-10-01

    Late time polarimetry can effectively probe the circumstellar (CS) dust environment of SNe Ia. We propose to acquire imaging polarimetry of SN 2014J at three epochs between 200-400 days after the SN explosion. The delayed light from optical maximum may be scattered into the line of sight and reveal the scattering dust through polarization. Light echoes from interstellar dust at very large distances (> 10pc) from the SN will not be highly polarized in these observations due to the small scattering angle involved. Polarimetry at late time is thus an unambegeous probe of CS dust very close to the SN (at distances ~ 1 light year). Observations of the illusive CS matter is critical in constraining the progenitor systems of SNIa.

  17. 2-Aminopurine hairpin probes for the detection of ultraviolet-induced DNA damage

    International Nuclear Information System (INIS)

    El-Yazbi, Amira F.; Loppnow, Glen R.

    2012-01-01

    Highlights: ► Molecular beacon with 2AP bases detects DNA damage in a simple mix-and-read assay. ► Molecular beacons with 2AP bases detect damage at a 17.2 nM limit of detection. ► The 2AP molecular beacon is linear over a 0–3.5 μM concentration range for damage. - Abstract: Nucleic acid exposure to radiation and chemical insults leads to damage and disease. Thus, detection and understanding DNA damage is important for elucidating molecular mechanisms of disease. However, current methods of DNA damage detection are either time-consuming, destroy the sample, or are too specific to be used for generic detection of damage. In this paper, we develop a fluorescence sensor of 2-aminopurine (2AP), a fluorescent analogue of adenine, incorporated in the loop of a hairpin probe for the quantification of ultraviolet (UV) C-induced nucleic acid damage. Our results show that the selectivity of the 2AP hairpin probe to UV-induced nucleic acid damage is comparable to molecular beacon (MB) probes of DNA damage. The calibration curve for the 2AP hairpin probe shows good linearity (R 2 = 0.98) with a limit of detection of 17.2 nM. This probe is a simple, fast and economic fluorescence sensor for the quantification of UV-induced damage in DNA.

  18. Estimating {sup 131}I biokinetics and radiation doses to the red marrow and whole body in thyroid cancer patients: probe detection versus image quantification

    Energy Technology Data Exchange (ETDEWEB)

    Willegaignon, Jose; Pelissoni, Rogerio Alexandre; Lima, Beatriz Christine de Godoy Diniz; Coura-Filho, George Barberio; Queiroz, Marcelo Araujo, E-mail: j.willegaignon@gmail.com [Instituto do Cancer do Estado de Sao Paulo Octavio Frias de Oliveira (ICESP), Sao Paulo, SP (Brazil); Sapienza, Marcelo Tatit; Buchpiguel, Carlos Alberto [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Departamento de Radiologia

    2016-05-15

    Objective: to compare the probe detection method with the image quantification method when estimating {sup 131}I biokinetics and radiation doses to the red marrow and whole body in the treatment of thyroid cancer patients. Materials and methods: fourteen patients with metastatic thyroid cancer, without metastatic bone involvement, were submitted to therapy planning in order to tailor the therapeutic amount of {sup 131}I to each individual. Whole-body scans and probe measurements were performed at 4, 24, 48, 72, and 96 h after {sup 131}I administration in order to estimate the effective half-life (T{sub eff}) and residence time of {sup 131}I in the body. Results: the mean values for T{sub eff} and residence time, respectively, were 19 ± 9 h and 28 ± 12 h for probe detection, compared with 20 ± 13 h and 29 ± 18 h for image quantification. The average dose to the red marrow and whole body, respectively, was 0.061 ± 0.041 mGy/MBq and 0.073 ± 0.040 mGy/MBq for probe detection, compared with 0.066 ± 0.055 mGy/MBq and 0.078 ± 0.056 mGy/MBq for image quantification. Statistical analysis proved that there were no significant differences between the two methods for estimating the T{sub eff} (p = 0.801), residence time (p = 0.801), dose to the red marrow (p = 0.708), and dose to the whole body (p = 0.811), even when we considered an optimized approach for calculating doses only at 4 h and 96 h after {sup 131}I administration (p > 0.914). Conclusion: there is full agreement as to the feasibility of using probe detection and image quantification when estimating {sup 131}I biokinetics and red-marrow/whole-body doses. However, because the probe detection method is ineffective in identifying tumor sites and critical organs during radionuclide therapy and therefore liable to skew adjustment of the amount of {sup 131}I to be administered to patients under such therapy, it should be used with caution. (author)

  19. Rapid detection and identification of pathogenic mycobacteria by combining radiometric and nucleic acid probe methods

    International Nuclear Information System (INIS)

    Ellner, P.D.; Kiehn, T.E.; Cammarata, R.; Hosmer, M.

    1988-01-01

    The combination of radiometric methodology (BACTEC 12B) and probe technology for recovery and identification of mycobacteria was studied in two large hospital laboratories. The sediment from vials with positive growth indices was tested with DNA probes specific for Mycobacterium tuberculosis, Mycobacterium avium, and Mycobacterium intracellulare. The sensitivity of the radiometric method and the specificity of the probes resulted in a marked reduction in the time to the final report. Biochemical testing could be eliminated on isolates giving a positive reaction with one of the probes. Some 176 isolates of M. tuberculosis, 110 of M. avium, and 5 of M. intracellulare were recovered. Two-thirds of these isolates were detected and identified within 2 weeks of inoculation and the remainder was detected by 4 weeks, a reduction of 5 to 7 weeks to the final report

  20. Two competing ionization processes in ESI-MS analysis of N-(1,3-diphenylallyl)benzenamines: formation of the unusual [M-H]+ ion versus the regular [M+H]+ ion.

    Science.gov (United States)

    Fang, Liwen; Dong, Cheng; Guo, Cheng; Xu, Jianxing; Liu, Qiaoling; Qu, Zhirong; Jiang, Kezhi

    2018-06-01

    A series of N-(1,3-diphenylallyl)benzenamine derivatives (M) were investigated by electrospray ionization mass spectrometry in the positive-ion mode. Both the anomalous [M-H] + and the regular [M+H] + were observed in the ESI mass spectra. The occurrence of [M-H] + has been supported by accurate mass spectrometry, liquid chromatography mass spectrometry, and tandem mass spectrometry analysis. Calculation results indicated that formation of [M-H] + is attributed to the ion-molecule reaction of M with the protonated ESI solvent molecule (e.g. CH 3 OH 2 + ) via hydride abstraction from a tertiary C sp3 -H. The competing ionization processes leading to [M-H] + or [M+H] + were significantly affected by the concentration of formic acid in the electrospray ionization solvent and the proton affinity of the N atom.

  1. The Oxford Probe: an open access five-hole probe for aerodynamic measurements

    Science.gov (United States)

    Hall, B. F.; Povey, T.

    2017-03-01

    The Oxford Probe is an open access five-hole probe designed for experimental aerodynamic measurements. The open access probe can be manufactured by the end user via additive manufacturing (metal or plastic). The probe geometry, drawings, calibration maps, and software are available under a creative commons license. The purpose is to widen access to aerodynamic measurement techniques in education and research environments. There are many situations in which the open access probe will allow results of comparable accuracy to a well-calibrated commercial probe. We discuss the applications and limitations of the probe, and compare the calibration maps for 16 probes manufactured in different materials and at different scales, but with the same geometrical design.

  2. The Oxford Probe: an open access five-hole probe for aerodynamic measurements

    International Nuclear Information System (INIS)

    Hall, B F; Povey, T

    2017-01-01

    The Oxford Probe is an open access five-hole probe designed for experimental aerodynamic measurements. The open access probe can be manufactured by the end user via additive manufacturing (metal or plastic). The probe geometry, drawings, calibration maps, and software are available under a creative commons license. The purpose is to widen access to aerodynamic measurement techniques in education and research environments. There are many situations in which the open access probe will allow results of comparable accuracy to a well-calibrated commercial probe. We discuss the applications and limitations of the probe, and compare the calibration maps for 16 probes manufactured in different materials and at different scales, but with the same geometrical design. (paper)

  3. Genetic analysis of attTn7, the transposon Tn7 attachment site in Escherichia coli, using a novel M13-based transduction assay.

    Science.gov (United States)

    Qadri, M I; Flores, C C; Davis, A J; Lichtenstein, C P

    1989-05-05

    The large (14 kb; kb = 10(3) bases) bacterial transposon, Tn7 (encoding resistance to trimethoprim and streptomycin/spectinomycin), has unusual properties. Like other elements, Tn7 transposes with low efficiency and low target-site specificity, but Tn7 also transposes, with high frequency in a unique orientation, to a preferred "attachment" site, called attTn7, in the Escherichia coli chromosome and similarly into plasmids containing attTn7. We developed a novel bacteriophage M13-based assay system to measure the transposition frequency of Tn7 to M13mp phage vectors containing attTn7 on a cloned 1 kb fragment of chromosomal DNA. Phage harvested from a Tn7 donor strain were used to infect recipient bacteria with selection for trimethoprim resistance. Transposition frequency, expressed as the number of trimethoprim-resistant colonies per plaque-forming unit, was found to be approximately 10(-4) to M13mp::attTn7, in contrast to 10(-10) to M13mp recombinants with approximately 1 kb insertions of other, "generic brand", DNA. By deletion analysis of M13mp::attTn7, we show that attTn7 is contained within a 64 base-pair region; sequences adjacent to the actual insertion site and encoding the carboxy terminus of the glmS gene are required. This assay also provided evidence for transposition immunity conferred by the right end of Tn7.

  4. Reconfigurable multiport EPON repeater

    Science.gov (United States)

    Oishi, Masayuki; Inohara, Ryo; Agata, Akira; Horiuchi, Yukio

    2009-11-01

    An extended reach EPON repeater is one of the solutions to effectively expand FTTH service areas. In this paper, we propose a reconfigurable multi-port EPON repeater for effective accommodation of multiple ODNs with a single OLT line card. The proposed repeater, which has multi-ports in both OLT and ODN sides, consists of TRs, BTRs with the CDR function and a reconfigurable electrical matrix switch, can accommodate multiple ODNs to a single OLT line card by controlling the connection of the matrix switch. Although conventional EPON repeaters require full OLT line cards to accommodate subscribers from the initial installation stage, the proposed repeater can dramatically reduce the number of required line cards especially when the number of subscribers is less than a half of the maximum registerable users per OLT. Numerical calculation results show that the extended reach EPON system with the proposed EPON repeater can save 17.5% of the initial installation cost compared with a conventional repeater, and can be less expensive than conventional systems up to the maximum subscribers especially when the percentage of ODNs in lightly-populated areas is higher.

  5. Cloning and Characterization of a Complex DNA Fingerprinting Probe for Candida parapsilosis

    Science.gov (United States)

    Enger, Lee; Joly, Sophie; Pujol, Claude; Simonson, Patricia; Pfaller, Michael; Soll, David R.

    2001-01-01

    Candida parapsilosis accounts for a significant number of nosocomial fungemias, but in fact, no effective and verified genetic fingerprinting method has emerged for assessing the relatedness of independent isolates for epidemiological studies. A complex 15-kb DNA fingerprinting probe, Cp3-13, was therefore isolated from a library of C. parapsilosis genomic DNA fragments. The efficacy of Cp3-13 for DNA fingerprinting was verified by a comparison of its clustering capacity with those of randomly amplified polymorphic DNA analysis and internally transcribed spacer region sequencing, by testing species specificity, and by assessing its capacity to identify microevolutionary changes both in vitro and in vivo. Southern blot hybridization of EcoRI/SalI-digested DNA with Cp3-13 provides a fingerprinting system that (i) identifies the same strain in independent isolates, (ii) discriminates between unrelated isolates, (iii) separates independent isolates into valid groups in a dendrogram, (iv) identifies microevolution in infecting populations, and (v) is amenable to automatic computer-assisted DNA fingerprint analysis. This probe is now available for epidemiological studies. PMID:11158125

  6. Structure-function relationship of viral coat proteins : a site-directed spectroscopic study of M13 coat protein

    NARCIS (Netherlands)

    Stopar, D.

    1997-01-01

    This thesis describes the results of a spectroscopic study of the major coat protein of bacteriophage M13. During the infection process this protein is incorporated into the cytoplasmic membrane of Escherichia coli host cells. To specifically monitor the local structural changes

  7. Dynamic viscosity versus probe-reported microviscosity of aqueous mixtures of poly(ethylene glycol)

    International Nuclear Information System (INIS)

    Bhanot, Chhavi; Trivedi, Shruti; Gupta, Arti; Pandey, Shubha; Pandey, Siddharth

    2012-01-01

    Highlights: ► Aqueous polymer mixtures, non-toxic media of huge industrial importance, are investigated. ► Bulk viscosity of aqueous. PEG mixtures is shown to vary widely with composition and temperature. ► T-dependent viscosity follows Arrhenius behavior suggesting aqueous PEGs to be Newtonian fluids. ► Microviscosity sensed by a fluorescence ratiometric probe is estimated and correlated with viscosity. ► Microviscosity correlates well with bulk viscosity at higher PEG concentrations. - Abstract: Correlation between the dynamic viscosity (η) and the microviscosity of a hybrid green medium constituted of water and poly(ethylene glycol) (PEG) of average molar mass (200, 400, and 600) g · mol −1 , respectively, is explored over the temperatures range (10 to 90) °C across the complete composition regime. The microviscosity is obtained using a fluorescence probe 1,3-bis-(1-pyrenyl)propane (BPP), which is manifested through the ratio of the monomer-to-intramolecular excimer intensities (I M /I E ). Aqueous PEG mixtures are observed to behave similar to Newtonian fluids as the temperature dependence of dynamic viscosity follows Arrhenius-type behavior. Surprisingly, a simple and convenient linear dependence of ln η with wt% PEG of the mixture is established. The BPP I M /I E is observed, in general, to increase with the bulk dynamic viscosity of the mixture having >10 wt% PEG suggesting a good correlation between the bulk dynamic viscosity and BPP-reported microviscosity when the viscosity of the aqueous PEG mixture is relatively high.

  8. Probe Techniques. Introductory Remarks

    Energy Technology Data Exchange (ETDEWEB)

    Emeleus, K. G. [School of Physics and Applied Mathematics, Queen' s University, Belfast (United Kingdom)

    1968-04-15

    In this brief introduction to the session on probes, the history of theii development is first touched on briefly. Reference is then made to the significance of the work to be described by Medicus, for conductivity and recombination calculations, and by Lam and Su, for a wide range of medium and higher pressure plasmas. Finally, a number of other probe topics are mentioned, including multiple probes; probes in electronegative plasmas; resonance probes; probes in noisy discharges; probes as oscillation detectors; use of probes where space-charge is not negligible. (author)

  9. Soil nitrogen mineralisation and organic matter composition revealed by 13C NMR spectroscopy under repeated prescribed burning in eucalypt forests of south-east Queensland

    International Nuclear Information System (INIS)

    Guinto, D. F.; Saffigna, P. G.; Xu, Z. H.; House, A. P. N.; Perera, M. C. S.

    1999-01-01

    The effects of burning on in situ extractable nitrogen (NH + 4 -N+NO - 3 -N) and net N mineralisation following scheduled fuel reduction burns in repeatedly burnt dry and wet sclerophyll forest sites in south-east Queensland were assessed. In addition, soil organic matter composition in the wet sclerophyll site was assessed by 13 C NMR spectroscopy. The results showed that at the dry sclerophyll site, extractable N and net N mineralisation for 1 year were largely unaffected by burning, while at the wet sclerophyll site, these parameters decreased. 13 C NMR analysis of soil samples from the wet sclerophyll site revealed that there was a significant reduction in the proportion of O-alkyl (alkoxy/carbohydrate) C with increasing burning frequency. Statistically significant effects on the other chemical shift regions were not detected. The ratio of alkyl C to O-alkyl C, a proposed index of organic matter decomposition, increased with increasing burning frequency. A high ratio of alkyl C to O-alkyl C suggests low amounts of carbohydrates relative to waxes and cutins, which could in turn lead to slower mineralisation. The findings are in accord with this hypothesis. There were significant linear relationships between cumulative N mineralisation for 1 year and the proportions of alkyl C and O-alkyl C, and the ratio of alkyl C/O-alkyl C. Thus, in addition to reductions in substrate quantity (low organic C and total N for burnt soils), there was also an alteration of substrate quality as revealed by 13 C NMR spectroscopy which is reflected in low N mineralisation. Copyright (1999) CSIRO Publishing

  10. Probe-diverse ptychography

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, I., E-mail: isaac.russellpeterson@rmit.edu.au [ARC Centre of Excellence for Coherent X-ray Science, the University of Melbourne, School of Physics, Victoria 3010 (Australia); Harder, R. [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); Robinson, I.K. [Research Complex at Harwell, Didcot, Oxfordshire OX11 0DE (United Kingdom); London Centre for Nanotechnology, University College London, London WC1H 0AH (United Kingdom)

    2016-12-15

    We propose an extension of ptychography where the target sample is scanned separately through several probes with distinct amplitude and phase profiles and a diffraction image is recorded for each probe and each sample translation. The resulting probe-diverse dataset is used to iteratively retrieve high-resolution images of the sample and all probes simultaneously. The method is shown to yield significant improvement in the reconstructed sample image compared to the image obtained using the standard single-probe ptychographic phase-retrieval scheme.

  11. Biological profile of 99mTc-HYNIC-βAla-NT(8-13) in MDAMB-231 breast cancer cell line

    International Nuclear Information System (INIS)

    Teodoro, Rodrigo; Faintuch, Bluma L.; Wiecek, Danielle P.; Silva, Natanael G.; Vallejo, Natalia M.

    2009-01-01

    Introduction: Neurotensin (NT) is a tridecapeptide involved in several growth-steps of human cancers. Recent studies postulated the role of NT and NT-receptor subtype 1 in breast cancer progression. However, the main drawback of natural NT is its rapid degradation in plasma. In an effort to develop a NT peptide-based radiopharmaceutical for the detection of breast cancer, the aim of this study was the radiolabeling of the double stabilized NT(8-13) peptide using HYNIC as chelating agent. Methods: Conjugated HYNIC-βAla-NT(8-13) was labeled with 99m Tc using tricine and EDDA as coligands. Radiochemical purity was checked by TLC and confirmed by RP-HPLC. 99m Tc-HYNIC-βAla-NT(8-13) (0.1 mL/74 MBq) was administered in Nude mice bearing MDA-MB-231 breast cancer cells and biodistribution studies were carried out at 30 and 90 min postinjection (pi). Blocking evaluation was also conducted by co-injection of 115 nmol of cold NT (8-13) analog. Planar gamma-camera imaging was acquired at the earlier time point studied. Results: Radiochemical purity of the radioconjugate was higher than 99%. Biodistribution studies revealed a very fast accumulation in tumor (1.97±0.18% ID/g, 30 min pi) with a sharply decrease at the later time point studied (0.44±0.02% ID/g). The specificity of the radioconjugate was evaluated with blockade studies. A reduction of 45.94%, 27.73% and 36.39% was found for tumor, large and small intestines, respectively, at 30 min pi. Otherwise, a less impressive blockade was observed for tumor and small intestine (28.68% and 24.90%, respectively) at the later time point studied. Conclusion: The results provide encouraging evidence in the development of radiolabeled NT(8-13) analogues for breast cancer diagnosis. (author)

  12. Development of novel imaging probe for optical/acoustic radiation imaging (OARI).

    Science.gov (United States)

    Ejofodomi, O'tega A; Zderic, Vesna; Zara, Jason M

    2013-11-01

    Optical/acoustic radiation imaging (OARI) is a novel imaging modality being developed to interrogate the optical and mechanical properties of soft tissues. OARI uses acoustic radiation force to generate displacement in soft tissue. Optical images before and after the application of the force are used to generate displacement maps that provide information about the mechanical properties of the tissue under interrogation. Since the images are optical images, they also represent the optical properties of the tissue as well. In this paper, the authors present the first imaging probe that uses acoustic radiation force in conjunction with optical coherence tomography (OCT) to provide information about the optical and mechanical properties of tissues to assist in the diagnosis and staging of epithelial cancers, and in particular bladder cancer. The OARI prototype probe consisted of an OCT probe encased in a plastic sheath, a miniaturized transducer glued to a plastic holder, both of which were encased in a 10 cm stainless steel tube with an inner diameter of 10 mm. The transducer delivered an acoustic intensity of 18 W/cm(2) and the OCT probe had a spatial resolution of approximately 10-20 μm. The tube was filled with deionized water for acoustic coupling and covered by a low density polyethylene cap. The OARI probe was characterized and tested on bladder wall phantoms. The phantoms possessed Young's moduli ranging from 10.2 to 12 kPa, mass density of 1.05 g/cm(3), acoustic attenuation coefficient of 0.66 dB/cm MHz, speed of sound of 1591 m/s, and optical scattering coefficient of 1.80 mm(-1). Finite element model (FEM) theoretical simulations were performed to assess the performance of the OARI probe. The authors obtained displacements of 9.4, 8.7, and 3.4 μm for the 3%, 4%, and 5% bladder wall phantoms, respectively. This shows that the probe is capable of generating optical images, and also has the ability to generate and track displacements in tissue. This will

  13. Probe measurements for impurity transport in the scrape-off layer of JIPP T-II

    International Nuclear Information System (INIS)

    Mohri, M.; Satake, T.; Hashiba, H.; Yamashina, T.; Amemiya, S.

    1982-05-01

    Impurity transport processes in the scrape-off layer of the JIPP T-II device have been studied by a probe method. A cubical silicon probe was inserted and exposed to 20 identical tokamak discharges in the scrape-off region. Deposited impurities were analyzed with use of AES, RBS and PIXE equipments. The main metallic impurities were molybdenum and iron whose deposition behavior was almost the same on any side of the probe, and their fluxes were observed to be 1.2 x 10 13 /cm 2 .discharge on the electron drift side and 5.2 x 10 13 /cm 2 .discharge on the ion drift side, respectively at the distance of 18.3 cm from the center line of the plasma. The mean transport energy of the impurities striking the probe surface was estimated from the depth concentration profile applying the LSS theory for iron as 90 eV on the electron drift side and 250 eV on the ion drift side, respectively. The e-folding length of the scrape-off plasma density was measured by the radial distribution of a deposited tantalum amount to be 0.64 cm on the electron drift side and 1.73 cm on the ion drift side, respectively. (author)

  14. Pump-probe nonlinear magneto-optical rotation with frequency-modulated light

    International Nuclear Information System (INIS)

    Pustelny, S.; Gawlik, W.; Jackson Kimball, D. F.; Rochester, S. M.; Yashchuk, V. V.; Budker, D.

    2006-01-01

    Specific types of atomic coherences between Zeeman sublevels can be generated and detected using a method based on nonlinear magneto-optical rotation with frequency-modulated light. Linearly polarized, frequency-modulated light is employed to selectively generate ground-state coherences between Zeeman sublevels for which Δm=2 and Δm=4 in 85 Rb and 87 Rb atoms, and additionally Δm=6 in 85 Rb. The atomic coherences are detected with a separate, unmodulated probe light beam. Separation of the pump and probe beams enables independent investigation of the processes of creation and detection of the atomic coherences. With the present technique the transfer of the Zeeman coherences, including high-order coherences, from excited to ground state by spontaneous emission has been observed

  15. Probing Single Pt Atoms in Complex Intermetallic Al13Fe4.

    Science.gov (United States)

    Yamada, Tsunetomo; Kojima, Takayuki; Abe, Eiji; Kameoka, Satoshi; Murakami, Yumi; Gille, Peter; Tsai, An Pang

    2018-03-21

    The atomic structure of a 0.2 atom % Pt-doped complex metallic alloy, monoclinic Al 13 Fe 4 , was investigated using a single crystal prepared by the Czochralski method. High-angle annular dark-field scanning transmission electron microscopy showed that the Pt atoms were dispersed as single atoms and substituted at Fe sites in Al 13 Fe 4 . Single-crystal X-ray structural analysis revealed that the Pt atoms preferentially substitute at Fe(1). Unlike those that have been reported, Pt single atoms in the surface layers showed lower activity and selectivity than those of Al 2 Pt and bulk Pt for propyne hydrogenation, indicating that the active state of a given single-atom Pt site is strongly dominated by the bonding to surrounding Al atoms.

  16. Probing the desert by the two-loop renormalization-group equations

    International Nuclear Information System (INIS)

    Tanimoto, M.; Suetake, Y.; Senba, K.

    1987-01-01

    We have reexamined the study of probing the desert with fermion masses, presented by Bagger, Dimopoulos, and Masso, by using the two-loop renormalization-group equations in the framework of the SU(3) x SU(2) x U(1) model with three generations and one Higgs doublet. The blow-up energy scale of the Yukawa coupling is found to be dependent on the Higgs quartic coupling λ. If the Yukawa coupling blows up between the electroweak scale M/sub W/ and the grand unified scale M/sub X/, the Higgs potential is destabilized for small values of λ at the electroweak scale M/sub W/, and becomes strongly coupled for large values of λ at M/sub W/. It is found that the Higgs-scalar mass as well as the fermion masses are important to probe the desert

  17. Assessing the acidity of high silica chabazite H-SSZ-13 by FTIR using CO as molecular probe: Comparison with H-SAPO-34.

    Science.gov (United States)

    Bordiga, Silvia; Regli, Laura; Cocina, Donato; Lamberti, Carlo; Bjørgen, Morten; Lillerud, Karl Petter

    2005-02-24

    Zeolitic materials based on the chabazite topology, such as H-SAPO-34, possess unique shape-selectivity properties for converting methanol into light olefins. In addition to the topology, zeolite acidity is inherently linked to catalyst activity and selectivity. The acidic properties of high silica chabazite (H-SSZ-13) have attracted much attention in the past decade because the material represents an idealized model system having one acidic site per cage. Conclusions drawn so far have essentially been founded on quantum chemical methods. An experimentally based benchmark of the acidity of H-SSZ-13 has hitherto not been available. In this work, transmission FTIR spectroscopy provides a description of the different acidic sites of H-SSZ-13 by using CO as molecular probe at 70 K. The results demonstrate that H-SSZ-13 is a strongly Brønsted acidic material, essentially having two distinct families of acidic sites. In contrast to numerous preceding reports, we find it fundamental to consider proton distributions among all four possible sites, and do not delimit the interpretations to only two sites. The present data consistently suggest the most abundant family of protons to have three members being located on different crystalline positions on the eight-membered-ring window giving access to the chabazite cage. Consequently, these protons are exposed to two neighboring cages. The second, and less abundant family, is constituted by only one site that is situated on the six-membered ring defining the top/bottom of the barrel-shaped chabazite cage. This proton is therefore only exposed to one cage and requires a higher CO pressure to form adducts. Toward CO, both families of sites possess the same acidity. Parallel experiments were also carried out for the isostructural and commercially important H-SAPO-34 having an equal density of acidic sites. This is the first attempt to directly compare, on an experimental basis, the acidity of these two materials.

  18. Electrical resistivity probes

    Science.gov (United States)

    Lee, Ki Ha; Becker, Alex; Faybishenko, Boris A.; Solbau, Ray D.

    2003-10-21

    A miniaturized electrical resistivity (ER) probe based on a known current-voltage (I-V) electrode structure, the Wenner array, is designed for local (point) measurement. A pair of voltage measuring electrodes are positioned between a pair of current carrying electrodes. The electrodes are typically about 1 cm long, separated by 1 cm, so the probe is only about 1 inch long. The electrodes are mounted to a rigid tube with electrical wires in the tube and a sand bag may be placed around the electrodes to protect the electrodes. The probes can be positioned in a borehole or on the surface. The electrodes make contact with the surrounding medium. In a dual mode system, individual probes of a plurality of spaced probes can be used to measure local resistance, i.e. point measurements, but the system can select different probes to make interval measurements between probes and between boreholes.

  19. Repeated Carbon-Cycle Disturbances at the Permian-Triassic Boundary Separate two Mass Extinctions

    Science.gov (United States)

    Nicol, J. A.; Watson, L.; Claire, M.; Buick, R.; Catling, D. C.

    2004-12-01

    Non-marine organic matter in Permian-Triassic sediments from the Blue Mountains, eastern Australia shows seven negative δ13C excursions of up to 7%, terminating with a positive excursion of 4%. Fluctuations start at the late Permian Glossopteris floral extinction and continue until just above the palynological Permian-Triassic boundary, correlated with the peak of marine mass extinction. The isotopic fluctuations are not linked to changes in depositional setting, kerogen composition or plant community, so they evidently resulted from global perturbations in atmospheric δ13C and/or CO2. The pattern was not produced by a single catastrophe such as a meteorite impact, and carbon-cycle calculations indicate that gas release during flood-basalt volcanism was insufficient. Methane-hydrate melting can generate a single -7% shift, but cannot produce rapid multiple excursions without repeated reservoir regeneration and release. However, the data are consistent with repeated overturning of a stratified ocean, expelling toxic gases that promoted sequential mass extinctions in the terrestrial and marine realms.

  20. Test-retest repeatability of myocardial oxidative metabolism and efficiency using standalone dynamic 11C-acetate PET and multimodality approaches in healthy controls.

    Science.gov (United States)

    Hansson, Nils Henrik; Harms, Hendrik Johannes; Kim, Won Yong; Nielsen, Roni; Tolbod, Lars P; Frøkiær, Jørgen; Bouchelouche, Kirsten; Poulsen, Steen Hvitfeldt; Wiggers, Henrik; Parner, Erik Thorlund; Sörensen, Jens

    2018-05-31

    Myocardial efficiency measured by 11 C-acetate positron emission tomography (PET) has successfully been used in clinical research to quantify mechanoenergetic coupling. The objective of this study was to establish the repeatability of myocardial external efficiency (MEE) and work metabolic index (WMI) by non-invasive concepts. Ten healthy volunteers (63 ± 4 years) were examined twice, one week apart, using 11 C-acetate PET, cardiovascular magnetic resonance (CMR), and echocardiography. Myocardial oxygen consumption from PET was combined with stroke work data from CMR, echocardiography, or PET to obtain MEE and WMI for each modality. Repeatability was estimated as the coefficient of variation (CV) between test and retest. MEE CMR , MEE Echo , and MEE PET values were 21.9 ± 2.7%, 16.4 ± 3.7%, and 23.8 ± 4.9%, respectively, P PET values were 4.42 ± 0.90, 4.07 ± 0.63, and 4.58 ± 1.13 mmHg × mL/m 2  × 10 6 , respectively, P = .45. Repeatability for MEE CMR was superior compared with MEE Echo but did not differ significantly compared with MEE PET (6.3% vs 12.9% and 9.4%, P = .04 and .25). CV values for WMI CMR , WMI Echo , and WMI PET were 10.0%, 14.8%, and 12.0%, respectively, (P = .53). Non-invasive measurements of MEE using 11 C-acetate PET are highly repeatable. A PET-only approach did not differ significantly from CMR/PET and might facilitate further clinical research due to lower costs and broader applicability.

  1. Spiroguanidine rhodamines as fluorogenic probes for lysophosphatidic acid

    Science.gov (United States)

    Wang, Lei; Sibrian-Vazquez, Martha; Escobedo, Jorge O.; Wang, Jialu; Moore, Richard G.

    2015-01-01

    Direct determination of total lysophosphatidic acid (LPA) was accomplished using newly developed spiroguanidines derived from rhodamine B as universal fluorogenic probes. Optimum conditions for the quantitative analysis of total LPA were investigated. The linear range for the determination of total LPA is up to 5 μM with a limit of detection of 0.512 μM. PMID:25516957

  2. Metastatic melanoma imaging using a novel Tc-99m-labeled lactam-cyclized alpha-MSH peptide.

    Science.gov (United States)

    Liu, Liqin; Xu, Jingli; Yang, Jianquan; Feng, Changjian; Miao, Yubin

    2017-11-15

    The purpose of this study was to determine the metastatic melanoma imaging property of 99m Tc(EDDA)-HYNIC-Aoc-Nle-CycMSH hex {hydrazinonicotinamide-8-aminooctanoic acid-Nle-c[Asp-His-DPhe-Arg-Trp-Lys]-CONH 2 }. HYNIC-Aoc-Nle-CycMSH hex was synthesized using fluorenylmethyloxy carbonyl (Fmoc) chemistry. The IC 50 value of HYNIC-Aoc-Nle-CycMSH hex was 0.78 ± 0.13 nM for B16/F10 melanoma cells. 99m Tc(EDDA)-HYNIC-Aoc-Nle-CycMSH hex displayed significantly higher uptake (14.26 ± 2.74 and 10.45 ± 2.31% ID/g) in B16/F10 metastatic melanoma-bearing lung than that in normal lung (0.90 ± 0.15 and 0.53 ± 0.14% ID/g) at 2 and 4 h post-injection, respectively. B16/F10 pulmonary metastatic melanoma lesions were clearly visualized by SPECT/CT using 99m Tc(EDDA)-HYNIC-Aoc-Nle-CycMSH hex as an imaging probe at 2 h post-injection, underscoring its potential as an imaging probe for metastatic melanoma detection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Impact of retinal pigment epithelium pathology on spectral-domain optical coherence tomography-derived macular thickness and volume metrics and their intersession repeatability.

    Science.gov (United States)

    Hanumunthadu, Daren; Wang, Jin Ping; Chen, Wei; Wong, Evan N; Chen, Yi; Morgan, William H; Patel, Praveen J; Chen, Fred K

    2017-04-01

    To determine the impact of retinal pigment epithelium (RPE) pathology on intersession repeatability of retinal thickness and volume metrics derived from Spectralis spectral-domain optical coherence tomography (Heidelberg Engineering, Heidelberg, Germany). Prospective cross-sectional single centre study. A total of 56 eyes of 56 subjects were divided into three groups: (i) normal RPE band (25 eyes); (ii) RPE elevation: macular soft drusen (13 eyes); and (iii) RPE attenuation: geographic atrophy or inherited retinal diseases (18 eyes). Each subject underwent three consecutive follow-up macular raster scans (61 B-scans at 119 μm separation) at 1-month intervals. Retinal thicknesses and volumes for each zone of the macular subfields before and after manual correction of segmentation error. Coefficients of repeatability (CR) were calculated. Mean (range) age was 57 (21-88) years. Mean central subfield thickness (CST) and total macular volume were 264 and 258 μm (P = 0.62), and 8.0 and 7.8 mm 3 (P = 0.31), before and after manual correction. Intersession CR (95% confidence interval) for CST and total macular volume were reduced from 40 (38-41) to 8.3 (8.1-8.5) and 0.62 to 0.16 mm 3 after manual correction of segmentation lines. CR for CST were 7.4, 23.5 and 66.7 μm before and 7.0, 10.9 and 7.6 μm after manual correction in groups i, ii and iii. Segmentation error in eyes with RPE disease has a significant impact on intersession repeatability of Spectralis spectral-domain optical coherence tomography macular thickness and volume metrics. Careful examination of each B-scan and manual adjustment can enhance the utility of quantitative measurement. Improved automated segmentation algorithms are needed. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  4. Lanthanide complexes as luminogenic probes to measure sulfide levels in industrial samples

    International Nuclear Information System (INIS)

    Thorson, Megan K.; Ung, Phuc; Leaver, Franklin M.; Corbin, Teresa S.; Tuck, Kellie L.; Graham, Bim; Barrios, Amy M.

    2015-01-01

    A series of lanthanide-based, azide-appended complexes were investigated as hydrogen sulfide-sensitive probes. Europium complex 1 and Tb complex 3 both displayed a sulfide-dependent increase in luminescence, while Tb complex 2 displayed a decrease in luminescence upon exposure to NaHS. The utility of the complexes for monitoring sulfide levels in industrial oil and water samples was investigated. Complex 3 provided a sensitive measure of sulfide levels in petrochemical water samples (detection limit ∼ 250 nM), while complex 1 was capable of monitoring μM levels of sulfide in partially refined crude oil. - Highlights: • Lanthanide–azide based sulfide sensors were synthesized and characterized. • The probes have excitation and emission profiles compatible with sulfide-contaminated samples from the petrochemical industry. • A terbium-based probe was used to measure the sulfide concentration in oil refinery wastewater. • A europium-based probe had compatibility with partially refined crude oil samples.

  5. Investigation of ferromagnetic spinel semiconductors by hyperfine interactions of implanted nuclear probes

    CERN Document Server

    Samokhvalov, V; Dietrich, M; Schneider, F; Tiginyanu, I M; Tsurkan, V; Unterricker, S

    2003-01-01

    The semiconducting ferromagnetic spinel compounds CdCr//2Se //4, CdCr //2S//4, HgCr//2Se//4 and CuCr//2Se//4 (metallic) were investigated by the perturbed angular correlations (PAC) method with the radioactive probes **1**1**1In, **1**1**1**mCd, **1**1**1Ag, **1**1**7Cd, **1**9**9**mHg and **7**7Br. The probes were implanted at the ISOLDE on-line separator (CERN-Geneva) into single crystals. From the time dependence of the PAC spectra and the measured hyperfine interaction parameters: electric field gradient and magnetic hyperfine field, the probe positions and the thermal behavior of the probes could be determined. Cd, Ag and Hg are substituted at the A-site, In at the A- and B-site in the semiconducting compounds and Br at the anion position. Electric and magnetic hyperfine fields were used as test quantities for theoretical charge and spin density distributions of LAPW calculations (WIEN97).

  6. Lanthanide complexes as luminogenic probes to measure sulfide levels in industrial samples

    Energy Technology Data Exchange (ETDEWEB)

    Thorson, Megan K. [Department of Medicinal Chemistry, University of Utah College of Pharmacy, Salt Lake City, UT 84108 (United States); Ung, Phuc [Monash Institute of Pharmaceutical Sciences, Monash University, Victoria 3052 (Australia); Leaver, Franklin M. [Water & Energy Systems Technology, Inc., Kaysville, UT 84037 (United States); Corbin, Teresa S. [Quality Services Laboratory, Tesoro Refining and Marketing, Salt Lake City, UT 84103 (United States); Tuck, Kellie L., E-mail: kellie.tuck@monash.edu [School of Chemistry, Monash University, Victoria 3800 (Australia); Graham, Bim, E-mail: bim.graham@monash.edu [Monash Institute of Pharmaceutical Sciences, Monash University, Victoria 3052 (Australia); Barrios, Amy M., E-mail: amy.barrios@utah.edu [Department of Medicinal Chemistry, University of Utah College of Pharmacy, Salt Lake City, UT 84108 (United States)

    2015-10-08

    A series of lanthanide-based, azide-appended complexes were investigated as hydrogen sulfide-sensitive probes. Europium complex 1 and Tb complex 3 both displayed a sulfide-dependent increase in luminescence, while Tb complex 2 displayed a decrease in luminescence upon exposure to NaHS. The utility of the complexes for monitoring sulfide levels in industrial oil and water samples was investigated. Complex 3 provided a sensitive measure of sulfide levels in petrochemical water samples (detection limit ∼ 250 nM), while complex 1 was capable of monitoring μM levels of sulfide in partially refined crude oil. - Highlights: • Lanthanide–azide based sulfide sensors were synthesized and characterized. • The probes have excitation and emission profiles compatible with sulfide-contaminated samples from the petrochemical industry. • A terbium-based probe was used to measure the sulfide concentration in oil refinery wastewater. • A europium-based probe had compatibility with partially refined crude oil samples.

  7. Micro sized implantable ball lens-based fiber optic probe design

    Science.gov (United States)

    Cha, Jaepyeong; Kang, Jin U.

    2014-02-01

    A micro sized implantable ball lens-based fiber optic probe design is described for continuous monitoring of brain activity in freely behaving mice. A prototype uses a 500-micron ball lens and a highly flexible 350-micron-diameter fiber bundle, which are enclosed by a 21G stainless steel sheath. Several types and thickness of brain tissue, consisting of fluorescent probes such as GFP, GCaMP3 calcium indicator, are used to evaluate the performance of the imaging probe. Measured working distance is approximately 400-μm, but is long enough to detect neural activities from cortical and cerebellar tissues of mice brain.

  8. Me saame USA lubadustesse uskuda: Lennart Meri kõne [Ameerika Ühendriikide asepresidendi Albert Gore'i visiidi ajal] Raekoja platsil 13. märtsil 1995 / Lennart Meri

    Index Scriptorium Estoniae

    Meri, Lennart, 1929-2006

    1995-01-01

    Kõne Raekoja platsil. Ilmunud ka: Päevaleht, 14. märts 1995, lk. 1, pealkiri: Lennart Meri kõne Raekoja platsil 13. märtsil 1995 ; Vaba Eestlane, 16. märts, lk. 3, 5, pealkiri: Vabariigi Presidendi Lennart Meri kõne Raekoja platsil 13. märtsil 1995. a. ; Meie Kodu, 29. märts, lk. 1

  9. The flow Rate Accuracy of Elastomeric Infusion Pumps After Repeated Filling.

    Science.gov (United States)

    Mohseni, Masood; Ebneshahidi, Amin

    2014-05-01

    One of the frequent applications of elastomeric infusion pumps is postoperative pain management. In daily practice, the disposable pumps get refilled with modified medication combinations in the successive days; although, the accuracy of infusion rates is unknown to clinicians. Our aim was to evaluate the effect of repeated filling on the delivery rate accuracy of an elastomeric pump available in our market. We examined 10 elastomeric infusion pumps (BOT-802, Nanchang Biotek Medical Device Company, China) with 100 mL capacity and nominal flow of 5 mL/h. Each pump was filled for three times, accounting for 30 series of experiments. A microset scaled in mL was used to measure the pump deliveries. Flow profile and reliability of infusion rate were analyzed after repeated use. The mean flow rate in the three series of measurements showed a gradual increase; however, the difference was not statistically significant (5.01 ± 0.07 vs. 5.03 ± 0.06 vs. 5.06 ± 0.08 mL/h; P = 0.81). The percentage of the flow rate error (deviation from 5 mL/h ± 15%) was 100% in the first and second hours of infusion, 96% in the third hour, 60% in the 20th hour and zero percent in the rest of the infusion time. This study indicated that the delivery rate accuracy of elastomeric infusion pumps is preserved after repeated usage. These laboratory findings suggested that elastomeric pumps could be safely refilled in the successive days to provide postoperative analgesia.

  10. The nitrite-oxidizing community in activated sludge from a municipal wastewater treatment plant determined by fatty acid methyl ester-stable isotope probing.

    Science.gov (United States)

    Kruse, Myriam; Zumbrägel, Sabine; Bakker, Evert; Spieck, Eva; Eggers, Till; Lipski, André

    2013-10-01

    Metabolically-active autotrophic nitrite oxidizers from activated sludge were labeled with (13)C-bicarbonate under exposure to different temperatures and nitrite concentrations. The labeled samples were characterized by FAME-SIP (fatty acid methyl ester-stable isotope probing). The compound cis-11-palmitoleic acid, which is the major lipid of the most abundant nitrite oxidizer in activated sludge, Candidatus Nitrospira defluvii, showed (13)C-incorporation in all samples exposed to 3 mM nitrite. Subsequently, the lipid cis-7-palmitoleic acid was labeled, and it indicated the activity of a nitrite oxidizer that was different from the known Nitrospira taxa in activated sludge. The highest incorporation of cis-7-palmitoleic acid label was found after incubation with a nitrite concentration of 0.3 mM at 17 and 22°C. While activity of Nitrobacter populations could not be detected by the FAME-SIP approach, an unknown nitrite oxidizer with the major lipid cis-9 isomer of palmitoleic acid exhibited (13)C-incorporation at 28°C with 30 mM nitrite. These results indicated flexibility of nitrite-oxidizing guilds in a complex community responding to different conditions. Labeled lipids so far not described for activated sludge-associated nitrifiers indicated the presence of unknown nitrite oxidizers in this habitat. The FAME-SIP-based information can be used to define appropriate conditions for the enrichment of nitrite-oxidizing guilds from complex samples. Copyright © 2013 Elsevier GmbH. All rights reserved.

  11. Repeated oral administration of capsaicin increases anxiety-like ...

    Indian Academy of Sciences (India)

    This study was conducted to examine the psycho-emotional effects of repeated oral exposure to capsaicin, the principal active component of chili peppers. Each rat received 1 mL of 0.02% capsaicin into its oral cavity daily, and was subjected to behavioural tests following 10 daily administrations of capsaicin. Stereotypy ...

  12. Isolation and characterization of human glycophorin A cDNAs using a synthetic oligonucleotide approach: nucleotide sequence, mRNA structure and regulation by 12-O-tetradecanoylphorbol 13-acetate (TPA)

    International Nuclear Information System (INIS)

    Siebert, P.D.; Fukuda, M.

    1986-01-01

    The authors have previously shown that treatment of human erythroleukemic K562 cells with the tumor-promoting phorbol ester, TPA, results in a diminished expression of glycophorin A at the level of protein biosynthesis and in vitro mRNA translation activity. To further examine the structure, relationships and expression of human glycophorins they have successfully isolated and sequenced several glycophorin A specific cDNA clones derived from K562 cells, by making extensive use of mixed and exact synthetic oligonucleotides as primers and radioactively labeled probes. The nucleotide sequence obtained from the largest glycophorin A cDNA suggests the presence of a hydrophobic leader-like peptide of at least 19 amino acids. Northern gel analysis using both whole cDNA-plasmid and synthetic oligonucleotide probes revealed the existence of multiple mRNAs, three of which they believe to be glycophorin A-specific, whereas a fourth and smaller mRNA appears to be glycophorin B-specific. Furthermore, the abundance of all four glycophorin mRNAs were found to be extensively reduced following treatment of K562 cells with TPA suggesting coordinate regulation, possibly at the level of gene transcription

  13. Fetal sex determination in the first trimester of pregnancy using a Y chromosome-specific DNA probe

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Y.; Huang, S.; Chen, M.; Huang, Y.; Zhang, M.; Dong, J.; Ku, A.; Xu, S.

    1987-05-01

    Prenatal determination of fetal sex is important for the prevention of X-linked disorders such as hemophilia, Lesch-Nyhan syndrome and Duchenne muscular dystrophy. The complex procedures of prenatal diagnosis for X-linked disorders are unnecessary if the fetus is female, because usually no clinical symptoms ever appear in female. pY 3.4 probe used in this work for sex determination is a 3.4 kilobase human repeat sequence. The probe is specific for the Y chromosome of males and can be used for sex determination. The other prove pBLUR used in this paper as control is a widely dispersed, highly repeated human Alu family DNA sequence, represented equally in male and female DNA. On the basis of the relative densities of the autoradiographic spots produced by hybridization of fetal DNA with pY3.4 and pBLUR, the sex of fetus can be clearly identified. Further the authors can determine the radioactive intensity (cpm) of the hybridized DNA spots and the ratio of hybridization with Y3.4 to pBLUR (Y3.4/pBLUR x 10). Results show that the hybridization ratio of DNA from chorionic villi of male (1.03 +/- 0.24) is significantly higher than that of female (0.16 +/- 0.09). Therefore, sex determination of the fetus can be made, based on the ratio of pY3.4/pBLUR x 10. If necessary they can also use Southern hybridization with pY 3.4 probe of DNA isolated from chorionic villi to confirm the result of dot hybridization.

  14. Detection of chromogranins A and B in endocrine tissues with radioactive and biotinylated oligonucleotide probes

    International Nuclear Information System (INIS)

    Lloyd, R.V.; Jin, L.; Fields, K.

    1990-01-01

    We analyzed the distribution of chromogranins A and B in normal and neoplastic endocrine tissues with secretory granules using 35 S-labeled and biotin-labeled oligonucleotide probes by in situ hybridization (ISH). Both radioactive and nonradioactive probes detected messenger RNAs (mRNAs) in frozen and paraffin tissue sections. Endocrine tissues with variable immunoreactivities for chromogranin A protein, such as small-cell lung carcinomas, neuroblastomas, insulinomas, and parathyroid adenomas, expressed the mRNA for chromogranins A and B in most cells. Some technical problems with the biotinylated probes included nonspecific nuclear staining and endogenous alkaline phosphatase, which was not completely abolished by levamisole pretreatment. A differential distribution of chromogranins A and B was seen in pituitary prolactinomas, which expressed abundant chromogranin B but not chromogranin A mRNAs, and in parathyroid adenomas, which expressed abundant chromogranin A but only small amounts of chromogranin B mRNAs. These results indicate that ISH can be used to detect chromogranins A and B in endocrine tissues with radioactive and biotinylated oligonucleotide probes and that the mRNAs for chromogranin A and B are demonstrable in some tumors even when the chromogranin proteins cannot be detected by immunohistochemistry

  15. Detection of chromogranins A and B in endocrine tissues with radioactive and biotinylated oligonucleotide probes

    Energy Technology Data Exchange (ETDEWEB)

    Lloyd, R.V.; Jin, L.; Fields, K. (Univ. of Michigan, Ann Arbor (USA))

    1990-01-01

    We analyzed the distribution of chromogranins A and B in normal and neoplastic endocrine tissues with secretory granules using {sup 35}S-labeled and biotin-labeled oligonucleotide probes by in situ hybridization (ISH). Both radioactive and nonradioactive probes detected messenger RNAs (mRNAs) in frozen and paraffin tissue sections. Endocrine tissues with variable immunoreactivities for chromogranin A protein, such as small-cell lung carcinomas, neuroblastomas, insulinomas, and parathyroid adenomas, expressed the mRNA for chromogranins A and B in most cells. Some technical problems with the biotinylated probes included nonspecific nuclear staining and endogenous alkaline phosphatase, which was not completely abolished by levamisole pretreatment. A differential distribution of chromogranins A and B was seen in pituitary prolactinomas, which expressed abundant chromogranin B but not chromogranin A mRNAs, and in parathyroid adenomas, which expressed abundant chromogranin A but only small amounts of chromogranin B mRNAs. These results indicate that ISH can be used to detect chromogranins A and B in endocrine tissues with radioactive and biotinylated oligonucleotide probes and that the mRNAs for chromogranin A and B are demonstrable in some tumors even when the chromogranin proteins cannot be detected by immunohistochemistry.

  16. Motywy podejmowania prób samobójczych przez młodzież w wieku 13-19 lat = Motives for suicide attempts by youth aged 13-19

    OpenAIRE

    Gmitrowicz, Agnieszka; Wolanek, Urszula; Madej, Agata; Makara-Studzińska, Marta

    2015-01-01

    Gmitrowicz Agnieszka, Wolanek Urszula, Madej Agata, Makara-Studzińska Marta. Motywy podejmowania prób samobójczych przez młodzież w wieku 13-19 lat = Motives for suicide attempts by youth aged 13-19. Journal of Education, Health and Sport. 2015;5(6):51-64. ISSN 2391-8306. DOI 10.5281/zenodo.18278 http://ojs.ukw.edu.pl/index.php/johs/article/view/2015%3B5%286%29%3A51-64 https://pbn.nauka.gov.pl/works/563208 http://dx.doi.org/10.5281/zenodo.18278 Formerly Journal of Health Scien...

  17. Efficient design of multituned transmission line NMR probes: the electrical engineering approach.

    Science.gov (United States)

    Frydel, J A; Krzystyniak, M; Pienkowski, D; Pietrzak, M; de Sousa Amadeu, N; Ratajczyk, T; Idzik, K; Gutmann, T; Tietze, D; Voigt, S; Fenn, A; Limbach, H H; Buntkowsky, G

    2011-01-01

    Transmission line-based multi-channel solid state NMR probes have many advantages regarding the cost of construction, number of RF-channels, and achievable RF-power levels. Nevertheless, these probes are only rarely employed in solid state-NMR-labs, mainly owing to the difficult experimental determination of the necessary RF-parameters. Here, the efficient design of multi-channel solid state MAS-NMR probes employing transmission line theory and modern techniques of electrical engineering is presented. As technical realization a five-channel ((1)H, (31)P, (13)C, (2)H and (15)N) probe for operation at 7 Tesla is described. This very cost efficient design goal is a multi port single coil transmission line probe based on the design developed by Schaefer and McKay. The electrical performance of the probe is determined by measuring of Scattering matrix parameters (S-parameters) in particular input/output ports. These parameters are compared to the calculated parameters of the design employing the S-matrix formalism. It is shown that the S-matrix formalism provides an excellent tool for examination of transmission line probes and thus the tool for a rational design of these probes. On the other hand, the resulting design provides excellent electrical performance. From a point of view of Nuclear Magnetic Resonance (NMR), calibration spectra of particular ports (channels) are of great importance. The estimation of the π/2 pulses length for all five NMR channels is presented. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Psychological and physiological responses following repeated peer death.

    Directory of Open Access Journals (Sweden)

    Judith Pizarro Andersen

    Full Text Available Undergraduates at a university in the United States were exposed - directly and indirectly - to 14 peer deaths during one academic year. We examined how individual and social factors were associated with psychological (e.g., anxiety, depression, somatization and physiological (i.e., cortisol distress responses following this unexpected and repeated experience with loss.Two to three months after the final peer death, respondents (N = 122, 61% female, 18-23 years, M = 20.13, SD = 1.14 reported prior adverse experiences, degree of closeness with the deceased, acute responses to the peer deaths, ongoing distress responses, social support, support seeking, and media viewing. A subset (n = 24 returned hair samples for evaluation of cortisol responses during the previous 3 months.Ongoing psychological distress was associated with a prior interpersonal trauma, b fewer social supports, and c media exposure to news of the deaths (p's25 p/mg compared to individuals with one or two prior bereavement experiences (who were, on average, within the normal range, 10 to 25 p/mg (p<.05. Only 8% of the sample utilized available university psychological or physical health resources and support groups.Limited research has examined the psychological and physiological impact of exposure to chronic, repeated peer loss, despite the fact that there are groups of individuals (e.g., police, military soldiers that routinely face such exposures. Prior adversity appears to play a role in shaping psychological and physiological responses to repeated loss. This topic warrants further research given the health implications of repeated loss for individuals in high-risk occupations and university settings.

  19. Radial-probe EBUS for the diagnosis of peripheral pulmonary lesions.

    Science.gov (United States)

    Jacomelli, Marcia; Demarzo, Sergio Eduardo; Cardoso, Paulo Francisco Guerreiro; Palomino, Addy Lidvina Mejia; Figueiredo, Viviane Rossi

    2016-01-01

    Conventional bronchoscopy has a low diagnostic yield for peripheral pulmonary lesions. Radial-probe EBUS employs a rotating ultrasound transducer at the end of a probe that is passed through the working channel of the bronchoscope. Radial-probe EBUS facilitates the localization of peripheral pulmonary nodules, thus increasing the diagnostic yield. The objective of this study was to present our initial experience using radial-probe EBUS in the diagnosis of peripheral pulmonary lesions at a tertiary hospital. We conducted a retrospective analysis of 54 patients who underwent radial-probe EBUS-guided bronchoscopy for the investigation of pulmonary nodules or masses between February of 2012 and September of 2013. Radial-probe EBUS was performed with a flexible 20-MHz probe, which was passed through the working channel of the bronchoscope and advanced through the bronchus to the target lesion. For localization of the lesion and for collection procedures (bronchial brushing, transbronchial needle aspiration, and transbronchial biopsy), we used fluoroscopy. Radial-probe EBUS identified 39 nodules (mean diameter, 1.9 ± 0.7 cm) and 19 masses (mean diameter, 4.1 ± 0.9 cm). The overall sensitivity of the method was 66.7% (79.5% and 25.0%, respectively, for lesions that were visible and not visible by radial-probe EBUS). Among the lesions that were visible by radial-probe EBUS, the sensitivity was 91.7% for masses and 74.1% for nodules. The complications were pneumothorax (in 3.7%) and bronchial bleeding, which was controlled bronchoscopically (in 9.3%). Radial-probe EBUS shows a good safety profile, a low complication rate, and high sensitivity for the diagnosis of peripheral pulmonary lesions. A broncoscopia convencional possui baixo rendimento diagnóstico para lesões pulmonares periféricas. A ecobroncoscopia radial (EBUS radial) emprega um transdutor ultrassonográfico rotatório na extremidade de uma sonda que é inserida no canal de trabalho do broncoscópio. O EBUS

  20. Observation of quantized vortices by cryocooler-based scanning Hall probe microscope

    Energy Technology Data Exchange (ETDEWEB)

    Tokunaga, Y.; Konishi, Y.; Tokunaga, M.; Tamegai, T

    2004-10-01

    We have developed a scanning Hall probe microscope (SHPM) system utilizing closed-cycle cryocooler. The Hall probe used in this system is fabricated from a GaAs/GaAlAs two-dimensional electron gas. A stepping-motor-driven XYZ translator is used with a resolution better than 0.1 {mu}m and maximum scan range of 20 x 20 mm{sup 2}. The spatial resolution of the system is about 5 {mu}m and magnetic resolution is about 100 mG. By using this system, we have successfully resolved the quantized vortices on the cleaved surface of Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+y} single crystal.

  1. A TaqI RFLP identified at the retinoblastoma locus on chromosome 13

    Energy Technology Data Exchange (ETDEWEB)

    Shiang, R; Murray, J C [Univ. of Iowa, Iowa City (USA); Wiggs, J; Dryja, T [Massachusetts Eye and Ear Infirmary, Boston (USA)

    1988-09-26

    Probe D95HS0.5 is a 0.6 kb fragment subcloned into Bluescribe a pUC19 derivative from a bacterio phage library isolated by a cDNA probe of the retinoblastoma gene. The fragment is released with the enzymes HindIII and SaII. TaqI identifies a 2 allele polymorphism with a band at 2.1 kb and 1.8 kb with a frequency of 0.97 and 0.03 respectively. There are no constant bands. The probe was assigned to chromosome 13 using a linkage analysis with retinoblastoma. Co-dominant inheritance was shown in 3 CEPH pedigrees.

  2. High spatial resolution Kelvin probe force microscopy with coaxial probes

    International Nuclear Information System (INIS)

    Brown, Keith A; Westervelt, Robert M; Satzinger, Kevin J

    2012-01-01

    Kelvin probe force microscopy (KPFM) is a widely used technique to measure the local contact potential difference (CPD) between an AFM probe and the sample surface via the electrostatic force. The spatial resolution of KPFM is intrinsically limited by the long range of the electrostatic interaction, which includes contributions from the macroscopic cantilever and the conical tip. Here, we present coaxial AFM probes in which the cantilever and cone are shielded by a conducting shell, confining the tip–sample electrostatic interaction to a small region near the end of the tip. We have developed a technique to measure the true CPD despite the presence of the shell electrode. We find that the behavior of these probes agrees with an electrostatic model of the force, and we observe a factor of five improvement in spatial resolution relative to unshielded probes. Our discussion centers on KPFM, but the field confinement offered by these probes may improve any variant of electrostatic force microscopy. (paper)

  3. Mechanism of Repeat-Associated MicroRNAs in Fragile X Syndrome

    Directory of Open Access Journals (Sweden)

    Karen Kelley

    2012-01-01

    Full Text Available The majority of the human genome is comprised of non-coding DNA, which frequently contains redundant microsatellite-like trinucleotide repeats. Many of these trinucleotide repeats are involved in triplet repeat expansion diseases (TREDs such as fragile X syndrome (FXS. After transcription, the trinucleotide repeats can fold into RNA hairpins and are further processed by Dicer endoribonuclases to form microRNA (miRNA-like molecules that are capable of triggering targeted gene-silencing effects in the TREDs. However, the function of these repeat-associated miRNAs (ramRNAs is unclear. To solve this question, we identified the first native ramRNA in FXS and successfully developed a transgenic zebrafish model for studying its function. Our studies showed that ramRNA-induced DNA methylation of the FMR1 5′-UTR CGG trinucleotide repeat expansion is responsible for both pathological and neurocognitive characteristics linked to the transcriptional FMR1 gene inactivation and the deficiency of its protein product FMRP. FMRP deficiency often causes synapse deformity in the neurons essential for cognition and memory activities, while FMR1 inactivation augments metabotropic glutamate receptor (mGluR-activated long-term depression (LTD, leading to abnormal neuronal responses in FXS. Using this novel animal model, we may further dissect the etiological mechanisms of TREDs, with the hope of providing insights into new means for therapeutic intervention.

  4. Detection of autotrophic verrucomicrobial methanotrophs in a geothermal environment using stable isotope probing

    Directory of Open Access Journals (Sweden)

    Christine eSharp

    2012-08-01

    Full Text Available Genomic analysis of the methanotrophic verrucomicrobium Methylacidiphilum infernorum strain V4 has shown that most pathways conferring its methanotrophic lifestyle are similar to those found in proteobacterial methanotrophs. However, due to the large sequence divergence of its methane monooxygenase-encoding genes (pmo, ‘universal’ pmoA polymerase chain reaction (PCR primers do not target these bacteria. Unlike proteobacterial methanotrophs, Methylacidiphilum fixes carbon autotrophically, and uses methane only for energy generation. As a result, techniques used to detect methanotrophs in the environment such as 13CH4-stable isotope probing (SIP and pmoA-targeted PCR do not detect verrucomicrobial methanotrophs, and they may have been overlooked in previous environmental studies. We developed a modified SIP technique to identify active methanotrophic verrucomicrobia in the environment by labelling with 13CO2 and 13CH4, individually and in combination. Testing the protocol in M. infernorum strain V4 resulted in assimilation of 13CO2 but not 13CH4, verifying its autotrophic lifestyle. To specifically detect methanotrophs (as opposed to other autotrophs via 13CO2-SIP, a quantitative PCR (qPCR assay specific for verrucomicrobial-pmoA genes was developed and used in combination with SIP. Incubation of an acidic, high-temperature geothermal soil with 13CH4 + 12CO2 caused little shift in the density distribution of verrucomicrobial-pmoA genes relative to controls. However, labelling with 13CO2 in combination with 12CH4 or 13CH4 induced a strong shift in the distribution of verrucomicrobial-pmoA genes towards the heavy DNA fractions. The modified SIP technique demonstrated that the primary methanotrophs active in the soil were autotrophs and belonged to the Verrucomicrobia. This is the first demonstration of autotrophic, non-proteobacterial methanotrophy in situ, and provides a tool to detect verrucomicrobial methanotrophs in other ecosystems.

  5. Detection of autotrophic verrucomicrobial methanotrophs in a geothermal environment using stable isotope probing.

    Science.gov (United States)

    Sharp, Christine E; Stott, Matthew B; Dunfield, Peter F

    2012-01-01

    Genomic analysis of the methanotrophic verrucomicrobium "Methylacidiphilum infernorum" strain V4 has shown that most pathways conferring its methanotrophic lifestyle are similar to those found in proteobacterial methanotrophs. However, due to the large sequence divergence of its methane monooxygenase-encoding genes (pmo), "universal" pmoA polymerase chain reaction (PCR) primers do not target these bacteria. Unlike proteobacterial methanotrophs, "Methylacidiphilum" fixes carbon autotrophically, and uses methane only for energy generation. As a result, techniques used to detect methanotrophs in the environment such as (13)CH(4)-stable isotope probing (SIP) and pmoA-targeted PCR do not detect verrucomicrobial methanotrophs, and they may have been overlooked in previous environmental studies. We developed a modified SIP technique to identify active methanotrophic Verrucomicrobia in the environment by labeling with (13)CO(2) and (13)CH(4), individually and in combination. Testing the protocol in "M. infernorum" strain V4 resulted in assimilation of (13)CO(2) but not (13)CH(4), verifying its autotrophic lifestyle. To specifically detect methanotrophs (as opposed to other autotrophs) via (13)CO(2)-SIP, a quantitative PCR (qPCR) assay specific for verrucomicrobial-pmoA genes was developed and used in combination with SIP. Incubation of an acidic, high-temperature geothermal soil with (13)CH(4) + (12)CO(2) caused little shift in the density distribution of verrucomicrobial-pmoA genes relative to controls. However, labeling with (13)CO(2) in combination with (12)CH(4) or (13)CH(4) induced a strong shift in the distribution of verrucomicrobial-pmoA genes towards the heavy DNA fractions. The modified SIP technique demonstrated that the primary methanotrophs active in the soil were autotrophs and belonged to the Verrucomicrobia. This is the first demonstration of autotrophic, non-proteobacterial methanotrophy in situ, and provides a tool to detect verrucomicrobial methanotrophs

  6. Expansion of protein domain repeats.

    Directory of Open Access Journals (Sweden)

    Asa K Björklund

    2006-08-01

    Full Text Available Many proteins, especially in eukaryotes, contain tandem repeats of several domains from the same family. These repeats have a variety of binding properties and are involved in protein-protein interactions as well as binding to other ligands such as DNA and RNA. The rapid expansion of protein domain repeats is assumed to have evolved through internal tandem duplications. However, the exact mechanisms behind these tandem duplications are not well-understood. Here, we have studied the evolution, function, protein structure, gene structure, and phylogenetic distribution of domain repeats. For this purpose we have assigned Pfam-A domain families to 24 proteomes with more sensitive domain assignments in the repeat regions. These assignments confirmed previous findings that eukaryotes, and in particular vertebrates, contain a much higher fraction of proteins with repeats compared with prokaryotes. The internal sequence similarity in each protein revealed that the domain repeats are often expanded through duplications of several domains at a time, while the duplication of one domain is less common. Many of the repeats appear to have been duplicated in the middle of the repeat region. This is in strong contrast to the evolution of other proteins that mainly works through additions of single domains at either terminus. Further, we found that some domain families show distinct duplication patterns, e.g., nebulin domains have mainly been expanded with a unit of seven domains at a time, while duplications of other domain families involve varying numbers of domains. Finally, no common mechanism for the expansion of all repeats could be detected. We found that the duplication patterns show no dependence on the size of the domains. Further, repeat expansion in some families can possibly be explained by shuffling of exons. However, exon shuffling could not have created all repeats.

  7. Movable Thomson scattering system based on optical fiber (TS-probe)

    International Nuclear Information System (INIS)

    Narihara, K.; Hayashi, H.

    2009-01-01

    This paper proposes a movable compact Thomson scattering (TS) system based on optical fibers (TS-probe). A TS-probe consists of a probe head, optical fiber, a laser-diode, polychromators and lock-in amplifiers. A laser beam optics and light collection optics are mounted rigidly on a probe head with a fixed scattering position. Laser light and scattered light are transmitted by flexible optical fibers, enabling us to move the TS-prove head freely during plasma discharge. The light signal scattered from an amplitude-modulated laser is detected against the plasma light based on the principle of the lock-in amplifier. With a modulated laser power of 300W, the scattered signal from a sheet plasma of 15 mm depth and n e -10 19 m -3 will be measured with 10% accuracy by setting the integrating time to 0.1 s. The TS-probe head is like a 1/20 model of the currently operating LHD-TS. (author)

  8. Imaging optical probe for pressurized 6200K steam-water environment

    International Nuclear Information System (INIS)

    Donaldson, M.R.; Pulfrey, R.E.; Merrill, S.K.

    1979-01-01

    An air-cooled imaging optical probe, 0.3 m long with a 25.4-mm outside diameter, has been built to provide high resolution viewing of flow regimes in a steam-water environment at 620 0 K and 15.5 MPa. The probe consists of a 3.5-mm-diameter rod lens borescope, surrounded by two coaxial coolant flow channels and two coaxial insulating dead air spaces. With air flowing through the probe at 5.7 g/s, thermal analysis shows that no part of the optical borescope will exceed 366 0 K when the probe is immersed in a 620 0 K environment. The objective lens is protected by a sapphire window which tests have shown can survive over 200 hours in 620 0 K water or steam with negligible loss of resolution and contrast. Condensation on the protective window is boiled off by electrically heating the window. Computer stress analysis, plus actual tests, shows that the probe can operate successfully with conservative safety factors

  9. Graphene oxide based contacts as probes of biomedical signals

    Science.gov (United States)

    Hallfors, N. G.; Devarajan, A.; Farhat, I. A. H.; Abdurahman, A.; Liao, K.; Gater, D. L.; Elnaggar, M. I.; Isakovic, A. F.

    We have developed a series of graphene oxide (GOx) on polymer contacts and have demonstrated these to be useful for collection of standard biomedically relevant signals, such as electrocardiogram (ECG). The process is wet solution-based and allows for control and tuning of the basic physical parameters of GOx, such as electrical and optical properties, simply by choosing the number of GOx layers. Our GOx characterization measurements show spectral (FTIR, XPS, IR absorbance) features most relevant to such performance, and point towards the likely explanations about the mechanisms for controlling the physical properties relevant for the contact performance. Structural (X-ray topography) and surface characterization (AFM, SEM) indicates to what degree these contacts can be considered homogeneous and therefore provide information on yield and repeatability. We compare the ECG signals recorded by standard commercial probes (Ag/AgCl) and GOx probes, displaying minor differences the solution to which may lead to a whole new way we perform ECG data collection, including wearable electronics and IoT friendly ECG monitoring. We acknowledge support from Mubadala-SRC AC4ES and from SRC 2011-KJ-2190. We thank J. B. Warren and G. L. Carr (BNL) for assistance.

  10. Overview of magnetic bias X-probe qualification and inspection of PNGS Monel 400 steam generator tubing

    International Nuclear Information System (INIS)

    Lepine, B.A.; Van Langen, J.; Obrutsky, L.

    2006-01-01

    This paper presents an overview of the X-probe MB 350, the qualification for detection of open OD axial crack-like flaws, and a selection of inspection results from the subsequent field inspections performed with this probe during the 2003 and 2004 period at Pickering Nuclear Generating Station A and B. Examples of the field indications to be presented are axial cracking, OD pitting at top of tubesheet location (TTS), and flow assisted corrosion (top hats). During the 2003 in-service eddy current inspection results of Pickering Nuclear Generating Station A (PNGS-A) Unit 2, a 13 mm (0.5 inch) long axial indication was detected by the CTR1 bobbin and CTR2-C4 array probes in Tube R25-C52 of Steam Generator (SG) 11 in the hot leg sludge pile region. An experimental magnetic bias X-probe, especially designed by Zetec for inspection of Monel 400 tubing, was deployed and the indication was characterized as a potential outer diameter (OD) axially oriented crack. Posterior tube pulling and destructive examination confirmed the presence of an Environmentally Assisted Crack (EAC), approximately 80% deep and 13 mm long. Due to the significance of this discovery, Ontario Power Generation (OPG) requested AECL to initiate a program for qualification of the X-Probe MB 350 for the detection of OD axial cracks in medium to high magnetic permeability (μ r ) Monel 400 PNGS-A and B steam generator tubing at different locations. The X-probe MB 350 subsequently has been deployed as a primary inspection probe for crack detection for PNGS steam generators. (author)

  11. The leucine-rich repeat structure.

    Science.gov (United States)

    Bella, J; Hindle, K L; McEwan, P A; Lovell, S C

    2008-08-01

    The leucine-rich repeat is a widespread structural motif of 20-30 amino acids with a characteristic repetitive sequence pattern rich in leucines. Leucine-rich repeat domains are built from tandems of two or more repeats and form curved solenoid structures that are particularly suitable for protein-protein interactions. Thousands of protein sequences containing leucine-rich repeats have been identified by automatic annotation methods. Three-dimensional structures of leucine-rich repeat domains determined to date reveal a degree of structural variability that translates into the considerable functional versatility of this protein superfamily. As the essential structural principles become well established, the leucine-rich repeat architecture is emerging as an attractive framework for structural prediction and protein engineering. This review presents an update of the current understanding of leucine-rich repeat structure at the primary, secondary, tertiary and quaternary levels and discusses specific examples from recently determined three-dimensional structures.

  12. An integrated genetic, physical, and transcriptional map of chromosome 13

    Energy Technology Data Exchange (ETDEWEB)

    Scheffer, H.; Kooy, R.F.; Wijngaard, A. [Univ. of Groningen (Netherlands)] [and others

    1994-09-01

    In this study a genetic map containing 20 markers and typed in 40 CEPH families is presented. It includes 7 thusfar untyped microsatellite markers, 7 that have previously been mapped on a subset of 8 CEPH families, one reference marker, D13S71, and three telomeric VNTR markers. Also, 4 intragenic RB1 markers were typed. The markers have an average heterozygosity of 73% (80%, excluding the three RFLPs). The total sex average length of the map is 140 cM. The mean female to male ratio is 1.54. For the non-telomeric part of the chromosome between the markers D13S221 in 13q12 and D13S173 in 13q33-q34, this ratio is 1.99. This ratio is reversed in the telomeric part of the chromosome between D13S173 and D13S234 in distal 13q34, where it is 0.47. A high new mutation frequency of 1% was detected in the (CTTT(T)){sub n} repeat in intron 20 of the RB1 gene. The map has been integrated with 7 microsatellite markers and 2 RFLP markers from CEPH database version 7.0, resulting in a map with 32 markers (28 loci) of chromosome 13q. In addition, a deletion hybrid breakpoint map ordering 50 markers in 18 intervals is constructed. It includes 32 microsatellite markers, 4 genes, 5 STSs, and 9 ESTs. Each of 18 intervals contains at least one microsatellite marker included in the extended genetic map. These data allow a correlation between the genetic and physical map of chromosome 13. New ESTs are currently being identified and localized at this integrated map.

  13. A CMOS 0.13 mu m, 5-Gb/s laser driver for high energy physics applications

    CERN Document Server

    Mazza, G; Moreira, P; Rivetti, A; Soos, C; Troska, J; Wyllie, K

    2012-01-01

    The GigaBit Laser Driver (GBLD) is a radiation tolerant ASIC designed to drive both edge emitting lasers and VCSELs at data rates up to 5 Gb/s. It is part of the GigaBit Transceiver (GBT) and Versatile Link projects, which are designing a bi-directional optical data transmission system capable of operating in the radiation environment of a typical HEP experiment. The GBLD can provide laser diode modulation currents up to 24 mA and laser bias currents up to 43 mA. Pre- and de-emphasis functions are implemented to compensate for high external capacitive loads and asymmetric laser response. The chip, designed in a 0.13 $\\mu$m CMOS technology, is powered by a single 2.5 V power supply and can be programmed via an $I2C$ interface.

  14. M1 suppression in pion photoproduction on 13C

    International Nuclear Information System (INIS)

    Tiator, L.

    1983-02-01

    Recently measured anomalously low cross sections for 13 C(γ,π - ) 13 N at low energy and theta sub(π)sup(lab) = 90 degrees have been analyzed in a DWIA calculation. It has been found that the EO contribution alone is able to explain the data, so that the MI cross section is expected to vanish. Using constraints from recent magnetic electron scattering, an explanation is possible by assuming a significantly lower reduced density matrix element for spin-flip isovector transitions with angular momentum L = 2 than predicted by Cohen-Kurath

  15. Study of simple sequence repeat (SSR) polymorphism for biotic ...

    African Journals Online (AJOL)

    home

    2013-10-02

    Oct 2, 2013 ... G. Siva Kumar1, K. Aruna Kumari1*, Ch. V. Durga Rani1, R. M. Sundaram2, S. Vanisree3, Md. ..... review by Jena and Mackill (2008) provided the list of .... repeat protein and is a member of a resistance gene cluster on rice.

  16. Probing active-edge silicon sensors using a high precision telescope

    NARCIS (Netherlands)

    Akiba, K.; Artuso, M.; van Beveren, V.; van Beuzekom, M.; Boterenbrood, H.; Buytaert, J.; Collins, P.; Dumps, R.; van der Heijden, B.; Hombach, C.; Hynds, D.; Hsu, D.; John, M.; Koffeman, E.; Leflat, A.; Li, Y.; Longstaff, I.; Morton, A.; PérezTrigo, E.; Plackett, R.; Reid, M.M.; Rodríguez Perez, P.; Schindler, H.; Tsopelas, P.; Vázquez Sierra, C.; Wysokiński, M.

    2015-01-01

    The performance of prototype active-edge VTT sensors bump-bonded to the Timepix ASIC is presented. Non-irradiated sensors of thicknesses 100-200 μm and pixel-to-edge distances of 50 μm and 100 μm were probed with a beam of charged hadrons with sub-pixel precision using the Timepix telescope

  17. An effective colorimetric and ratiometric fluorescent probe for bisulfite in aqueous solution

    International Nuclear Information System (INIS)

    Dai, Xi; Zhang, Tao; Du, Zhi-Fang; Cao, Xiang-Jian; Chen, Ming-Yu; Hu, Sheng-Wen; Miao, Jun-Ying; Zhao, Bao-Xiang

    2015-01-01

    We have developed the first two-photon colorimetric and ratiometric fluorescent probe, BICO, for the detection of bisulfite (HSO 3 − ) in aqueous solution. The probe contains coumarin and benzimidazole moieties and can detect HSO 3 − based on the Michael addition reaction with a limit of detection 5.3 × 10 −8  M in phosphate-buffered saline solution. The probe was used to detect bisulfite in tap water, sugar and dry white wine. Moreover, test strips were made and used easily. We successfully applied the probe to image living cells, using one-photon fluorescence imaging. BICO overcomes the limitations in sensitivity of previously reported probes and the solvation effect of bisulfite, which demonstrates its excellent value in practical application. - Highlights: • A colorimetric and ratiometric fluorescent probe was developed. • The probe could detect bisulfite in PBS buffer solution and real samples. • Bisulfite test paper was made to naked-eye detect bisulfite. • This probe successfully used to living cell imaging in ratiometric manner

  18. An effective colorimetric and ratiometric fluorescent probe for bisulfite in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Xi [Institute of Organic Chemistry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Zhang, Tao [Institute of Developmental Biology, School of Life Science, Shandong University, Jinan 250100 (China); Du, Zhi-Fang; Cao, Xiang-Jian; Chen, Ming-Yu [Institute of Organic Chemistry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Taishan College, Shandong University, Jinan 250100 (China); Hu, Sheng-Wen [Institute of Organic Chemistry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Miao, Jun-Ying, E-mail: miaojy@sdu.edu.cn [Institute of Developmental Biology, School of Life Science, Shandong University, Jinan 250100 (China); Zhao, Bao-Xiang, E-mail: bxzhao@sdu.edu.cn [Institute of Organic Chemistry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China)

    2015-08-12

    We have developed the first two-photon colorimetric and ratiometric fluorescent probe, BICO, for the detection of bisulfite (HSO{sub 3}{sup −}) in aqueous solution. The probe contains coumarin and benzimidazole moieties and can detect HSO{sub 3}{sup −} based on the Michael addition reaction with a limit of detection 5.3 × 10{sup −8} M in phosphate-buffered saline solution. The probe was used to detect bisulfite in tap water, sugar and dry white wine. Moreover, test strips were made and used easily. We successfully applied the probe to image living cells, using one-photon fluorescence imaging. BICO overcomes the limitations in sensitivity of previously reported probes and the solvation effect of bisulfite, which demonstrates its excellent value in practical application. - Highlights: • A colorimetric and ratiometric fluorescent probe was developed. • The probe could detect bisulfite in PBS buffer solution and real samples. • Bisulfite test paper was made to naked-eye detect bisulfite. • This probe successfully used to living cell imaging in ratiometric manner.

  19. The rise in carboxyhemoglobin from repeated pulmonary diffusing capacity tests.

    Science.gov (United States)

    Zavorsky, Gerald S

    2013-03-01

    The purpose of this study determined the rise in carboxyhemoglobin percentage (COHb) from repeated pulmonary diffusing capacity tests using 5 or 10s single breath-hold maneuvers. Five male and four female non-smokers [baseline COHb=1.2 (SD 0.5%)] performed repeated pulmonary diffusing capacity testing on two separate days. The days were randomized to either repeated 10s (0.28% CO), or 5s (0.28% CO, 55ppm NO) breath-hold maneuvers. Twenty-two 5s breath-hold maneuvers, each separated by 4min rest, raised COHb to 11.1 (1.4)% and minimally raised the methemoglobin percentage (METHb) by 0.3 (0.2)% to a value of 0.8 (0.2)%. After the 22nd test, pulmonary diffusing capacity for carbon monoxide (DLCO) was reduced by about 4mL/min/mmHg, equating to a 0.44% increase in COHb per 5s breath-hold maneuver and a concomitant 0.35mL/min/mmHg decrease in DLCO. Pulmonary diffusing capacity for nitric oxide (DLNO) was not altered after 22 tests. On another day, the 10s single breath-hold maneuver increased COHb by 0.64% per test, and reduced DLCO by 0.44mL/min/mmHg per test. In conclusion, 5s breath-hold maneuvers do not appreciably raise METHb or DLNO, and DLCO is only significantly reduced when COHb is at least 6%. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Assessment of an ultrasonic sensor and a capacitance probe for measurement of two-phase mixture level

    International Nuclear Information System (INIS)

    Kim, Chang Hyun; Lee, Dong Won; No, Hee Cheon

    2004-01-01

    We perform a comparison of two-phase mixture levels measured by an ultrasonic sensor and a two-wire type capacitance probe with visual data under the same experimental conditions. A series of experiments are performed with various combinations of airflow and initial water level using a test vessel with a height of 2m and an inner diameter of 0.3 m under atmospheric pressure and room temperature. The ultrasonic sensor measures the two-phase mixture level with a maximum error of 1.77% with respect to the visual data. The capacitance probe severely under-predicts the level data in the high void fraction region. The cause of the error is identified as the change of the dielectric constant as the void fraction changes when the probe is applied to the measurement of the two-phase mixture levels. A correction method for the capacitance probe is proposed by correcting the change of dielectric constant of the two-phase mixture. The correction method for the capacitance probe produces a r.m.s. error of 5.4%. (author)

  1. ECR plasma diagnostics with Langmuir probe

    International Nuclear Information System (INIS)

    Kenez, L.; Biri, S.; Valek, A.

    2000-01-01

    the ATOMKI. The specialty of this power supply is that we will continuously control the bias voltage of the probe from -500 V tp +500 V with 0.1 V accuracy. Also we can simultaneously measure the electron and ion currents with 0.01 mA accuracy. We designed a new mechanism which will enable us to scan the whole volume of the plasma chamber. One of our plans for the future is to apply this probe to explain the effect of external electron injection into the plasma. (author)

  2. Cross-sections for formation of 99mTc through natRu(n,x) 99mTc reaction induced by neutrons at 13.5 and 14.8 MeV

    International Nuclear Information System (INIS)

    Luo Junhua; Han Jiuning; Tuo Fei; Kong Xiangzhong; Liu Rong; Jiang Li

    2012-01-01

    The cross-sections for formation of metastable state of 99 Tc ( 99m Tc, 140.511 keV, 6.01 h) through nat Ru(n,x) 99m Tc reaction induced by 13.5 MeV and 14.8 MeV neutrons were measured. Fast neutrons were produced via the 3 H(d,n) 4 He reaction on the K-400 neutron generator. Induced gamma activities were measured by a high-resolution gamma-ray spectrometer with a high-purity germanium (HpGe) detector. Measurements were corrected for gamma-ray attenuations, dead time and fluctuation of neutron flux. Data for nat Ru(n,x) 99m Tc reaction cross sections are reported to be 9.6±1.5 and 9.2±1.1 mb at 13.5±0.2 and 14.8±0.2 MeV incident neutron energies, respectively. Results were compared with the data by other authors. - Highlights: ► D–T neutron source was used to measure cross sections using activation method. ► 27 Al(n,α) 24 Na was used as the monitor for the measurement. ► Cross-sections for formation of 99m Tc through nat Ru(n,x) 99m Tc were measured. ► Data for nat Ru(n,x) 99m Tc reaction cross sections are reported. ► The results were discussed and compared with experimental data in the literature.

  3. Multiple-targeted graphene-based nanocarrier for intracellular imaging of mRNAs

    International Nuclear Information System (INIS)

    Wang, Ying; Li, Zhaohui; Liu, Misha; Xu, Jinjin; Hu, Dehong; Lin, Yuehe; Li, Jinghong

    2017-01-01

    Simultaneous detection and imaging of multiple intracellular messenger RNA (mRNAs) hold great significant for early cancer diagnostics and preventive medicine development. Herein, we propose a multiple-targeted graphene oxide (GO) nanocarrier that can simultaneously detect and image different type mRNAs in living cells. First of all, in vitro detection of multiple targets have been realized successfully based on the multiple-targeted GO nanocarrier with linear relationship ranging from 3 nM to 200 nM, as well as sensitive detection limit of 1.84 nM for manganese superoxide dismutase (Mn-SOD) mRNA and 2.45 nM for β-actin mRNA. Additionally, this nanosensing platform composed of fluorescent labelled single strand DNA probes and GO nanocarrier can identify Mn-SOD mRNA and endogenous mRNA of β-actin in living cancer cells, showing rapid response, high specificity, nuclease stability, and good biocompatibility during the cell imaging. Thirdly, changes of the expression levels of mRNA in living cells before or after the drug treatment can be monitored successfully. By using multiple ssDNA as probes and GO nanocarrier as the cellular delivery cargo, the proposed simultaneous multiple-targeted sensing platform will be of great potential as a powerful tool for intracellular trafficking process from basic research to clinical diagnosis. - Graphical abstract: Schematic illustration of simultaneously multiple mRNAs monitoring inside single living breast cancer cell based on GO nanocarrier. In particular, the fluorescent signals could be monitored when Mn-SOD probe (red) and β-actin probe (green) hybridizes with their mRNA targets inside the living cells. Random probe (orange) was regarded as control probe for the sensing strategy. - Highlights: • A multiple-targeted GO nanocarrier was used for mRNAs imaging and expression changes after drug treatment can be monitored successfully. • Sensitive detection limit of 1.84 nM for manganese superoxide dismutase (Mn-SOD) m

  4. High-resolution spectra of stars in globular clusters. VI - Oxygen-deficient red giant stars in M13

    International Nuclear Information System (INIS)

    Brown, J.A.; Wallerstein, G.; Oke, J.B.

    1991-01-01

    From high-resolution, high signal-to-noise spectra, abundances of carbon, nitrogen, and oxygen and the C-12/C-13 ratio for five red giants in M13, including star II-67, which has previously been reported to be deficient in oxygen have been determined. Three of the five stars exhibit substantial oxygen deficiencies; O/Fe values range from +0.5 to less than about 0.3. The sum of the CNO nuclides is the same for all stars, which is interpreted as evidence that mixing of CNO-cycled material into the envelope is the cause of the variations in oxygen abundance. 41 refs

  5. Calcium-induced tertiary structure modifications of endo-B-1,3-glucanase form Pyrococcus furiosus in 7.9 M guanidinium chloride

    NARCIS (Netherlands)

    Chiaraluce, R.; Gianese, G.; Angelaccio, S.; Florio, R.; Lieshout, van J.F.T.; Oost, van der J.; Consalvi, V.

    2005-01-01

    The family 16 endo-b-1,3 glucanase from the extremophilic archaeon Pyrococcus furiosus is a laminarinase, which in 7.9 M GdmCl (guanidinium chloride) maintains a significant amount of tertiary structure without any change of secondary structure. The addition of calcium to the enzyme in 7.9 M GdmCl

  6. Development of plasma diagnostics technologies - Measurement of transport= parameters in tokamak edge plasma by using electric transport probes

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Kyu Sun; Chang, Do Hee; Sim, Yeon Gun; Kim, Jin Hee [Hanyang University, Seoul (Korea, Republic of)

    1995-08-01

    Electric transport probe system is developed for the measurement of electron temperature, floating potential, plasma density and flow velocity of= edge plasmas in the KT-2 medium size tokamak. Experiments have been performed in KT-1 small size tokamak. Electric transport probe is composed of a single probe(SP) and a Mach probe (MP). SP is used for the measurements of electron density, floating potential, and plasma density and measured values are {approx} 3*10{sup 11}/cm{sup -3}, -20 volts, 15 {approx} 25 eV. For the most discharges, respectively. MP is for the measurements of toroidal(M{sub T}) and poloidal(M{sub P}) flow velocities, and density, which are M{sub T} {approx_equal} .0.85, M{sub P} {approx_equal}. 0.17, n. {approx_equal} 2.1*10{sup 11} cm{sup -3}, respectively. A triple probe is also developed for the direct reading of T{sub e} and n{sub e}, and is used for DC, RF, and RF+DC plasma in APL of Hanyang university. 38 refs., 36 figs. (author)

  7. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    Science.gov (United States)

    Provenzano, Virgil; Della Torre, Edward; Bennett, Lawrence H.; ElBidweihy, Hatem

    2014-02-01

    The Gd5Ge2Si2 alloy and the off-stoichiometric Ni50Mn35In15 Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd5Ge2Si2 and Ni50Mn35In15 alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis.

  8. Hysteresis of magnetostructural transitions: Repeatable and non-repeatable processes

    International Nuclear Information System (INIS)

    Provenzano, Virgil; Della Torre, Edward; Bennett, Lawrence H.; ElBidweihy, Hatem

    2014-01-01

    The Gd 5 Ge 2 Si 2 alloy and the off-stoichiometric Ni 50 Mn 35 In 15 Heusler alloy belong to a special class of metallic materials that exhibit first-order magnetostructural transitions near room temperature. The magnetic properties of this class of materials have been extensively studied due to their interesting magnetic behavior and their potential for a number of technological applications such as refrigerants for near-room-temperature magnetic refrigeration. The thermally driven first-order transitions in these materials can be field-induced in the reverse order by applying a strong enough field. The field-induced transitions are typically accompanied by the presence of large magnetic hysteresis, the characteristics of which are a complicated function of temperature, field, and magneto-thermal history. In this study we show that the virgin curve, the major loop, and sequentially measured MH loops are the results of both repeatable and non-repeatable processes, in which the starting magnetostructural state, prior to the cycling of field, plays a major role. Using the Gd 5 Ge 2 Si 2 and Ni 50 Mn 35 In 15 alloys, as model materials, we show that a starting single phase state results in fully repeatable processes and large magnetic hysteresis, whereas a mixed phase starting state results in non-repeatable processes and smaller hysteresis

  9. Giant panda (Ailuropoda melanoleuca) sperm morphometry and function after repeated freezing and thawing.

    Science.gov (United States)

    Santiago-Moreno, J; Esteso, M C; Pradiee, J; Castaño, C; Toledano-Díaz, A; O'Brien, E; Lopez-Sebastián, A; Martínez-Nevado, E; Delclaux, M; Fernández-Morán, J; Zhihe, Z

    2016-05-01

    This work examines the effects of subsequent cycles of freezing-thawing on giant panda (Ailuropoda melanoleuca) sperm morphometry and function, and assesses whether density-gradient centrifugation (DGC) can increase the number of freezing-thawing cycles this sperm can withstand. A sperm sample was collected by electroejaculation from a mature giant panda and subjected to five freezing-thawing cycles. Although repeated freezing-thawing negatively affected (P 60% of the sperm cells in both treatments showed acrosome integrity even after the fifth freezing cycle. In fresh semen, the sperm head length was 4.7 μm, the head width 3.6 μm, area 14.3 μm(2) and perimeter length 14.1 μm. The present results suggest that giant panda sperm trends to be resistant to repeated freezing-thawing, even without DGC selection. © 2015 Blackwell Verlag GmbH.

  10. Revisiting the TALE repeat.

    Science.gov (United States)

    Deng, Dong; Yan, Chuangye; Wu, Jianping; Pan, Xiaojing; Yan, Nieng

    2014-04-01

    Transcription activator-like (TAL) effectors specifically bind to double stranded (ds) DNA through a central domain of tandem repeats. Each TAL effector (TALE) repeat comprises 33-35 amino acids and recognizes one specific DNA base through a highly variable residue at a fixed position in the repeat. Structural studies have revealed the molecular basis of DNA recognition by TALE repeats. Examination of the overall structure reveals that the basic building block of TALE protein, namely a helical hairpin, is one-helix shifted from the previously defined TALE motif. Here we wish to suggest a structure-based re-demarcation of the TALE repeat which starts with the residues that bind to the DNA backbone phosphate and concludes with the base-recognition hyper-variable residue. This new numbering system is consistent with the α-solenoid superfamily to which TALE belongs, and reflects the structural integrity of TAL effectors. In addition, it confers integral number of TALE repeats that matches the number of bound DNA bases. We then present fifteen crystal structures of engineered dHax3 variants in complex with target DNA molecules, which elucidate the structural basis for the recognition of bases adenine (A) and guanine (G) by reported or uncharacterized TALE codes. Finally, we analyzed the sequence-structure correlation of the amino acid residues within a TALE repeat. The structural analyses reported here may advance the mechanistic understanding of TALE proteins and facilitate the design of TALEN with improved affinity and specificity.

  11. DNA probes

    International Nuclear Information System (INIS)

    Castelino, J.

    1992-01-01

    The creation of DNA probes for detection of specific nucleotide segments differs from ligand detection in that it is a chemical rather than an immunological reaction. Complementary DNA or RNA is used in place of the antibody and is labelled with 32 P. So far, DNA probes have been successfully employed in the diagnosis of inherited disorders, infectious diseases, and for identification of human oncogenes. The latest approach to the diagnosis of communicable and parasitic infections is based on the use of deoxyribonucleic acid (DNA) probes. The genetic information of all cells is encoded by DNA and DNA probe approach to identification of pathogens is unique because the focus of the method is the nucleic acid content of the organism rather than the products that the nucleic acid encodes. Since every properly classified species has some unique nucleotide sequences that distinguish it from every other species, each organism's genetic composition is in essence a finger print that can be used for its identification. In addition to this specificity, DNA probes offer other advantages in that pathogens may be identified directly in clinical specimens

  12. A repetitive probe for FISH analysis of bovine interphase nuclei

    Directory of Open Access Journals (Sweden)

    Cribiu Edmond

    2000-03-01

    Full Text Available Abstract The purpose of this study was to generate repetitive DNA sequence probes for the analysis of interphase nuclei by fluorescent in situ hybridisation (FISH. Such probes are useful for the diagnosis of chromosomal abnormalities in bovine preimplanted embryos. Of the seven probes (E1A, E4A, Ba, H1A, W18, W22, W5 that were generated and partially sequenced, five corresponded to previously described Bos taurus repetitive DNA (E1A, E4A, Ba, W18, W5, one probe (W22 shared no homology with other DNA sequences and one (H1A displayed a significant homology with Rattus norvegicus mRNA for secretin receptor transmembrane domain 3. Fluorescent in situ hybridisation was performed on metaphase bovine fibroblast cells and showed that five of the seven probes hybridised most centromeres (E1A, E4A, Ba, W18, W22, one labelled the arms of all chromosomes (W5 and the H1A probe was specific to three chromosomes (ch14, ch20, and ch25. Moreover, FISH with H1A resulted in interpretable signals on interphase nuclei in 88% of the cases, while the other probes yielded only dispersed overlapping signals.

  13. Theory and practice of near-field thermal probes for microscopy and thermal analysis

    International Nuclear Information System (INIS)

    Hodges, C.S.

    1999-03-01

    Bacterial mats called biofilms that form on the surfaces of industrial steel pipes can cause corrosion of the pipe. Examining the steel surface of the corroded pipe usually involves removal of the biofilm using acid. This acid can also cause corrosion of the pipe so that the observed corrosion cracks and pits are the result of both the acid and the biofilm. It was thought that non-invasive examination of the corrosion caused by the biofilm may be obtained by using a thin wire bent into a loop that acts as both a heat source a nd a detector of heat, measuring the changes in heat flow out of the wire as the wire passes over the steel with the biofilm still present. This technique of using a heated probe to scan samples on a microscopic scale is called Scanning Thermal Microscopy (SThM) and uses an alternating current to produce a.c. thermal waves that emanate from the probe tip into the sample. The alternating current allows better signal-to-noise ratios and also selective depth imaging of the sample since the thermal wave penetrates into the sample a distance inversely proportional to the applied current frequency. Reversal in the contrast of SThM images on biofilms and subsequently all samples was observed as either the frequency or the amplitude of the temperature waves was altered. Whilst changing the time constant of the feedback circuit attached to the SThM probe did go some way to explain this effect, a full explanation is still wanting. Despite many efforts to image the biofilm/steel interface with the biofilm still present, often the biofilm was either too thick or too complicated to do this. A simpler thermal test sample is required to calibrate the thermal probe. In addition to SThM, one may select a point on a sample surface and ramp the temperature of the probe to obtain a Localised Thermal Analysis (LTA) temperature scan looking for melts, recrystallisations, glass transitions of the part of the sample in contact with the probe. This technique is a

  14. Cross-sections for formation of {sup 89}Zr{sup m} through {sup 90}Zr(n,2n){sup 89}Zr{sup m} reaction over neutron energy range 13.73 MeV to 14.77 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Attar, F.M.D. [Department of Physics, University of Pune, Pune-411007 (India); Mandal, R. [Department of Physics, University of Pune, Pune-411007 (India); Indian Institute of Technology, Kharagpur (India); Dhole, S.D. [Department of Physics, University of Pune, Pune-411007 (India); Saxena, A. [Nuclear Physics Division, BARC, Mumbai (India); Ashokkumar,; Ganesan, S. [Reactor Physics Design Division, BARC, Mumbai (India); Kailas, S. [Nuclear Physics Division, BARC, Mumbai (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Pune-411007 (India)], E-mail: vnb@physics.unipune.ernet.in

    2008-04-01

    The cross-sections for formation of metastable state of {sup 89}Zr ({sup 89}Zr{sup m}, 0.588 MeV, 4.16 m) through {sup 90}Zr(n,2n){sup 89}Zr{sup m} reaction induced by 13.73 MeV to 14.77 MeV neutrons were measured for the first time and also theoretically estimated using Empire-II and Talys programs. At 13.73 MeV neutron energy, the {sup 89}Zr nuclei can be excited to metastable state, {sup 89}Zr{sup m}, when the first and the second emitted neutrons have energies lower than the most probable energy {approx}0.64 MeV. The probability of exciting {sup 89}Zr nuclei to energy levels higher than 0.588 MeV and therefore of populating the metastable state through decay process increases with increasing neutron energy. The measured cross-sections vary from 41{+-}3mb to 221{+-}15mb over neutron energies 13.73 MeV to 14.77 MeV, and are in agreement with the cross-sections estimated using Empire-II code. The formation of {sup 89}Zr{sup m} is favoured when the first and the second reaction neutrons are emitted with the most probable energies rather than lower energy, except for 13.73 MeV neutrons.

  15. On-tip sub-micrometer Hall probes for magnetic microscopy prepared by AFM lithography

    International Nuclear Information System (INIS)

    Gregusova, D.; Martaus, J.; Fedor, J.; Kudela, R.; Kostic, I.; Cambel, V.

    2009-01-01

    We developed a technology of sub-micrometer Hall probes for future application in scanning hall probe microscopy (SHPM) and magnetic force microscopy (MFM). First, the Hall probes of ∼9-μm dimensions are prepared on the top of high-aspect-ratio GaAs pyramids with an InGaP/AlGaAs/GaAs active layer using wet-chemical etching and non-planar lithography. Then we show that the active area of planar Hall probes can be downsized to sub-micrometer dimensions by local anodic oxidation technique using an atomic force microscope. Such planar probes are tested and their noise and magnetic field sensitivity are evaluated. Finally, the two technologies are combined to fabricate sub-micrometer Hall probes on the top of high-aspect ratio mesa for future SHPM and MFM techniques.

  16. Scanning probe lithography for nanoimprinting mould fabrication

    International Nuclear Information System (INIS)

    Luo Gang; Xie Guoyong; Zhang Yongyi; Zhang Guoming; Zhang Yingying; Carlberg, Patrick; Zhu Tao; Liu Zhongfan

    2006-01-01

    We propose a rational fabrication method for nanoimprinting moulds by scanning probe lithography. By wet chemical etching, different kinds of moulds are realized on Si(110) and Si(100) surfaces according to the Si crystalline orientation. The structures have line widths of about 200 nm with a high aspect ratio. By reactive ion etching, moulds with patterns free from the limitation of Si crystalline orientation are also obtained. With closed-loop scan control of a scanning probe microscope, the length of patterned lines is more than 100 μm by integrating several steps of patterning. The fabrication process is optimized in order to produce a mould pattern with a line width about 10 nm. The structures on the mould are further duplicated into PMMA resists through the nanoimprinting process. The method of combining scanning probe lithography with wet chemical etching or reactive ion etching (RIE) provides a resistless route for the fabrication of nanoimprinting moulds

  17. Assessment of an ultrasonic sensor and a capacitance probe for measurement of two-phase mixture level

    International Nuclear Information System (INIS)

    Kim, Chang Hyun; Lee, Dong Won; No, Hee Cheon

    2004-01-01

    We performed a comparison of two-phase mixture levels measured by an ultrasonic sensor and a two-wire type capacitance probe with visual data under the same experimental conditions. A series of experiments are performed with various combinations of airflow and initial water level using a test vessel with a height of 2m and an inner diameter of 0.3m. The ultrasonic sensor measured the two-phase mixture level with a maximum error of 1.77% with respect to the visual data. The capacitance probe severely under-predicted the level data in the high void fraction region. The cause of the error was identified as the change of the dielectric constant as the void fraction changes when the probe is applied to the measurement of the two-phase mixture levels. A correction method for the capacitance probe is proposed by correcting the change of the dielectric constant of the two-phase mixture. The correction method for the capacitance probe produces a r.m.s. error of 5.4%. The present experimental data are compared with the existing pool void fraction correlations based on drift-flux model. The Kataoka-Ishii correlation has the best agreement with the present experimental data with an r.m.s error of 2.5%

  18. Probing lipid membrane electrostatics

    Science.gov (United States)

    Yang, Yi

    The electrostatic properties of lipid bilayer membranes play a significant role in many biological processes. Atomic force microscopy (AFM) is highly sensitive to membrane surface potential in electrolyte solutions. With fully characterized probe tips, AFM can perform quantitative electrostatic analysis of lipid membranes. Electrostatic interactions between Silicon nitride probes and supported zwitterionic dioleoylphosphatidylcholine (DOPC) bilayer with a variable fraction of anionic dioleoylphosphatidylserine (DOPS) were measured by AFM. Classical Gouy-Chapman theory was used to model the membrane electrostatics. The nonlinear Poisson-Boltzmann equation was numerically solved with finite element method to provide the potential distribution around the AFM tips. Theoretical tip-sample electrostatic interactions were calculated with the surface integral of both Maxwell and osmotic stress tensors on tip surface. The measured forces were interpreted with theoretical forces and the resulting surface charge densities of the membrane surfaces were in quantitative agreement with the Gouy-Chapman-Stern model of membrane charge regulation. It was demonstrated that the AFM can quantitatively detect membrane surface potential at a separation of several screening lengths, and that the AFM probe only perturbs the membrane surface potential by external field created by the internai membrane dipole moment. The analysis yields a dipole moment of 1.5 Debye per lipid with a dipole potential of +275 mV for supported DOPC membranes. This new ability to quantitatively measure the membrane dipole density in a noninvasive manner will be useful in identifying the biological effects of the dipole potential. Finally, heterogeneous model membranes were studied with fluid electric force microscopy (FEFM). Electrostatic mapping was demonstrated with 50 nm resolution. The capabilities of quantitative electrostatic measurement and lateral charge density mapping make AFM a unique and powerful

  19. Assessment of the Idaho National Laboratory Hot Fuel Examination Facility Stack Monitoring Site for Compliance with ANSI/HPS N13.1 1999

    International Nuclear Information System (INIS)

    Glissmeyer, John A.; Flaherty, Julia E.

    2010-01-01

    This document reports on a series of tests to determine whether the location of the air sampling probe in the Hot Fuels Examination Facility (HFEF) heating, ventilation and air conditioning (HVAC) exhaust duct meets the applicable regulatory criteria regarding the placement of an air sampling probe. Federal regulations require that a sampling probe be located in the exhaust stack according to the criteria of the ANSI/HPS N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that is representative of the effluent stream. The tests conducted by PNNL during July 2010 on the HFEF system are described in this report. The sampling probe location is approximately 20 feet from the base of the stack. The stack base is in the second floor of the HFEF, and has a building ventilation stream (limited potential radioactive effluent) as well as a process stream (potential radioactive effluent, but HEPA-filtered) that feeds into it. The tests conducted on the duct indicate that the process stream is insufficiently mixed with the building ventilation stream. As a result, the air sampling probe location does not meet the criteria of the N13.1-1999 standard. The series of tests consists of various measurements taken over a grid of points in the duct cross section at the proposed sampling-probe location. The results of the test series on the HFEF exhaust duct as it relates to the criteria from ANSI/HPS N13.1-1999 are desribed in this report. Based on these tests, the location of the air sampling probe does not meet the requirements of the ANSI/HPS N13.1-1999 standard, and modifications must be made to either the HVAC system or the air sampling probe for compliance. The recommended approaches are discussed and vary from sampling probe modifications to modifying the junction of the two air exhaust streams.

  20. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  1. Biological profile of {sup 99m}Tc-HYNIC-betaAla-NT(8-13) in MDAMB-231 breast cancer cell line

    Energy Technology Data Exchange (ETDEWEB)

    Teodoro, Rodrigo; Faintuch, Bluma L.; Wiecek, Danielle P.; Silva, Natanael G.; Vallejo, Natalia M., E-mail: teodoro_rodrigo@yahoo.com.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Diretoria de Radiofarmacia

    2009-07-01

    Introduction: Neurotensin (NT) is a tridecapeptide involved in several growth-steps of human cancers. Recent studies postulated the role of NT and NT-receptor subtype 1 in breast cancer progression. However, the main drawback of natural NT is its rapid degradation in plasma. In an effort to develop a NT peptide-based radiopharmaceutical for the detection of breast cancer, the aim of this study was the radiolabeling of the double stabilized NT(8-13) peptide using HYNIC as chelating agent. Methods: Conjugated HYNIC-betaAla-NT(8-13) was labeled with {sup 99m}Tc using tricine and EDDA as coligands. Radiochemical purity was checked by TLC and confirmed by RP-HPLC. {sup 99m}Tc-HYNIC-betaAla-NT(8-13) (0.1 mL/74 MBq) was administered in Nude mice bearing MDA-MB-231 breast cancer cells and biodistribution studies were carried out at 30 and 90 min postinjection (pi). Blocking evaluation was also conducted by co-injection of 115 nmol of cold NT (8-13) analog. Planar gamma-camera imaging was acquired at the earlier time point studied. Results: Radiochemical purity of the radioconjugate was higher than 99%. Biodistribution studies revealed a very fast accumulation in tumor (1.97+-0.18% ID/g, 30 min pi) with a sharply decrease at the later time point studied (0.44+-0.02% ID/g). The specificity of the radioconjugate was evaluated with blockade studies. A reduction of 45.94%, 27.73% and 36.39% was found for tumor, large and small intestines, respectively, at 30 min pi. Otherwise, a less impressive blockade was observed for tumor and small intestine (28.68% and 24.90%, respectively) at the later time point studied. Conclusion: The results provide encouraging evidence in the development of radiolabeled NT(8-13) analogues for breast cancer diagnosis. (author)

  2. All-photonic quantum repeaters

    Science.gov (United States)

    Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2015-01-01

    Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153

  3. Membrane insertion and assembly of epitope-tagged gp9 at the tip of the M13 phage

    Directory of Open Access Journals (Sweden)

    Kuhn Andreas

    2011-09-01

    Full Text Available Abstract Background Filamentous M13 phage extrude from infected Escherichia coli with a tip structure composed of gp7 and gp9. This tip structure is extended by the assembly of the filament composed of the major coat protein gp8. Finally, gp3 and gp6 terminate the phage structure at the proximal end. Up to now, gp3 has been the primary tool for phage display technology. However, gp7, gp8 and gp9 could also be used for phage display and these phage particles should bind to two different or more surfaces when the modified coat proteins are combined. Therefore, we tested here if the amino-terminal end of gp9 can be modified and whether the modified portion is exposed and detectable on the M13 phage particles. Results The amino-terminal region of gp9 was modified by inserting short sequences that encode antigenic epitopes. We show here that the modified gp9 proteins correctly integrate into the membrane using the membrane insertase YidC exposing the modified epitope into the periplasm. The proteins are then efficiently assembled onto the phage particles. Also extensions up to 36 amino acid residues at the amino-terminal end of gp9 did not interfere with membrane integration and phage assembly. The exposure of the antigenic tags on the phage was visualised with immunogold labelling by electron microscopy and verified by dot blotting with antibodies to the tags. Conclusions Our results suggest that gp9 at the phage tip is suitable for the phage display technology. The modified gp9 can be supplied in trans from a plasmid and fully complements M13 phage with an amber mutation in gene 9. The modified phage tip is very well accessible to antibodies.

  4. Electrostatic probes in luminescent discharges

    International Nuclear Information System (INIS)

    Cunha Raposo, C. da.

    1980-01-01

    A system to produce luminescent type plasma by continuos discharge and ionization by high frequency was constructed. The ionization was done in the air and in the argon under pressures from 3 to 10 mmHg. The parameters of a non magnetized collisional plasma and the parameters of a magnetized plasma such as, density, eletron temperature and potential, using a Langmuir probe with plane geometry, were determined. (M.C.K.) [pt

  5. Relationships Among Two Repeated Activity Tests and Aerobic Fitness of Volleyball Players.

    Science.gov (United States)

    Meckel, Yoav; May-Rom, Moran; Ekshtien, Aya; Eisenstein, Tamir; Nemet, Dan; Eliakim, Alon

    2015-08-01

    The purpose of the study was to determine performance indices of a repeated sprint test (RST) and to examine their relationships with performance indices of a repeated jump test (RJT) and with aerobic fitness among trained volleyball players. Sixteen male volleyball players performed RST (6 × 30 m sprints), RJT (6 sets of 6 consecutive jumps), and an aerobic power test (20-m Shuttle Run Test). Performance indices for the RST and the RJT were (a) the ideal 30-m run time (IS), the total run time (TS) of the 6 sprints, and the performance decrement (PD) during the test and (b) the ideal jump height (IJ), the total jump height (TJ) of all the jumps, and the PD during the test, respectively. No significant correlations were found between performance indices of the RST and RJT. Significant correlations were found between PD, IS, and TS in the RST protocol and predicted peak V[Combining Dot Above]O2 (r = -0.60, -0.75, -0.77, respectively). No significant correlations were found between performance indices of the RJT (IJ, TJ, and PD) and peak V[Combining Dot Above]O2. The findings suggest that a selection of repeated activity test protocols should acknowledge the specific technique used in the sport, and that a distinct RJT, rather than the classic RST, is more appropriate for assessing the anaerobic capabilities of volleyball players. The findings also suggest that aerobic fitness plays only a minor role in performance maintenance throughout characteristic repeated jumping activity of a volleyball game.

  6. Nanosecond dynamics of influenza A/M2TM and an amantadine resistant mutant probed by time-dependent red shifts of a native tryptophan

    Energy Technology Data Exchange (ETDEWEB)

    Nanda, Vikas [Center for Advanced Biotechnology and Medicine, Robert Wood Johnson Medical School – UMDNJ, Piscataway, NJ 08854 (United States); Department of Biochemistry, Robert Wood Johnson Medical School – UMDNJ, Piscataway, NJ 08854 (United States); Cristian, Lidia [Department of Biochemistry and Biophysics, School of Medicine, University of Pennsylvania, Philadelphia, PA 19104-6059 (United States); Toptygin, Dmitri; Brand, Ludwig [Department of Biology, Johns Hopkins University, Baltimore, MD 21218 (United States); DeGrado, William F., E-mail: William.Degrado@ucsf.edu [Department of Pharmaceutical Chemistry, University of California, San Francisco, CA 94158 (United States)

    2013-08-30

    Highlights: ► Examined nanosecond dynamics of essential tryptophan residue of M2 proton channel. ► Channel blocking drugs restrict the ability of M2 to stabilize charge. ► Dielectric relaxation of M2 consistent with molecular dynamics simulation studies. - Abstract: Proteins involved in functions such as electron transfer or ion transport must be capable of stabilizing transient charged species on time scales ranging from picoseconds to microseconds. We study the influenza A M2 proton channel, containing a tryptophan residue that serves as an essential part of the proton conduction pathway. We induce a transition dipole in tryptophan by photoexcitation, and then probe the dielectric stabilization of its excited state. The magnitude of the stabilization over this time regime was larger than that generally found for tryptophan in membrane or protein environments. M2 achieves a water-like stabilization over a 25 ns time scale, slower than that of bulk water, but sufficiently rapid to contribute to stabilization of charge as protons diffuse through the channel. These measurements should stimulate future MD studies to clarify the role of sidechain versus non-bulk water in defining the process of relaxation.

  7. Synthesis of ¹³C-lidocaine as a probe of breath test for the evaluation of cytochrome P450 activity.

    Science.gov (United States)

    Mitome, Hidemichi; Sugiyama, Erika; Sato, Hitoshi; Akira, Kazuki

    2014-01-01

    (13)C-Labeled lidocaine, 2-di[1-(13)C]ethylamino-N-(2,6-dimethylphenyl)acetamide (1), was synthesized from [1-(13)C]acetic acid in six steps, as a probe for a breath test to evaluate in vivo cytochrome P450 activity. The measurement of (13)CO2 in breath was successfully performed following oral administration of (13)C-lidocaine 1 to mice.

  8. Design and fabrication of an actively cooled Langmuir probe for long pulse applications

    International Nuclear Information System (INIS)

    Paterson, J.A.; Biagi, L.A.; Ehlers, K.W.; Koehler, G.W.

    1985-11-01

    The details of the mechanical design and fabrication for a Langmuir Probe for the continuous monitoring of plasma density are given. The probe was designed for use as a diagnostic tool in the development of long pulse positive ion plasma sources for use on neutral beam systems. The essential design feature of this probe is the incorporation of two electrically isolated cooling water circuits which actively cool the probe tip and probe jacket. The electrical isolation is required to prevent drain currents from the probe body disturbing the measurement of the probe tip current and thereby the plasma density measurement. The successful realization of the design requires precision components and vacuum tight ceramic to refractory metal brazes. To date this design has successfully operated in steady-state in plasma densities up to 250 mA/cm 2 and surface heat fluxes of 25 W/cm 2

  9. Signalling chains with probe and adjust learning

    Science.gov (United States)

    Gosti, Giorgio

    2018-04-01

    Many models explain the evolution of signalling in repeated stage games on social networks, differently in this study each signalling game evolves a communication strategy to transmit information across the network. Specifically, I formalise signalling chain games as a generalisation of Lewis' signalling games, where a number of players are placed on a chain network and play a signalling game in which they have to propagate information across the network. I show that probe and adjust learning allows the system to develop communication conventions, but it may temporarily perturb the system out of conventions. Through simulations, I evaluate how long the system takes to evolve a signalling convention and the amount of time it stays in it. This discussion presents a mechanism in which simple players can evolve signalling across a social network without necessarily understanding the entire system.

  10. Application of focused ion beam for the fabrication of AFM probes

    Science.gov (United States)

    Kolomiytsev, A. S.; Lisitsyn, S. A.; Smirnov, V. A.; Fedotov, A. A.; Varzarev, Yu N.

    2017-10-01

    The results of an experimental study of the probe tips fabrication for critical-dimension atomic force microscopy (CD-AFM) using the focused ion beam (FIB) induced deposition are presented. Methods of the FIB-induced deposition of tungsten and carbon onto the tip of an AFM probe are studied. Based on the results obtained in the study, probes for the CD-AFM technique with a tip height about 1 μm and radius of 20 nm were created. The formation of CD-AFM probes by FIB-induced deposition allows creating a high efficiency tool for nanotechnology and nanodiagnostics. The use of modified cantilevers allows minimizing the artefacts of AFM images and increasing the accuracy of the relief measurement. The obtained results can be used for fabrication of AFM probes for express monitoring of the technological process in the manufacturing of the elements for micro- and nanoelectronics.

  11. Mobile probes

    DEFF Research Database (Denmark)

    Ørngreen, Rikke; Jørgensen, Anna Neustrup; Noesgaard, Signe Schack

    2016-01-01

    A project investigating the effectiveness of a collection of online resources for teachers' professional development used mobile probes as a data collection method. Teachers received questions and tasks on their mobile in a dialogic manner while in their everyday context as opposed...... to in an interview. This method provided valuable insight into the contextual use, i.e. how did the online resource transfer to the work practice. However, the research team also found that mobile probes may provide the scaffolding necessary for individual and peer learning at a very local (intra-school) community...... level. This paper is an initial investigation of how the mobile probes process proved to engage teachers in their efforts to improve teaching. It also highlights some of the barriers emerging when applying mobile probes as a scaffold for learning....

  12. {sup 13}C-NMR studies on disulfide bond isomerization in bovine pancreatic trypsin inhibitor (BPTI)

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Mitsuhiro [Kumamoto University, Department of Structural BioImaging, Faculty of Life Sciences (Japan); Miyanoiri, Yohei [Nagoya University, Structural Biology Research Center, Graduate School of Science (Japan); Terauchi, Tsutomu [Tokyo Metropolitan University, Graduate School of Science and Engineering (Japan); Kainosho, Masatsune, E-mail: kainosho@tmu.ac.jp [Nagoya University, Structural Biology Research Center, Graduate School of Science (Japan)

    2016-09-15

    Conformational isomerization of disulfide bonds is associated with the dynamics and thus the functional aspects of proteins. However, our understanding of the isomerization is limited by experimental difficulties in probing it. We explored the disulfide conformational isomerization of the Cys14–Cys38 disulfide bond in bovine pancreatic trypsin inhibitor (BPTI), by performing an NMR line-shape analysis of its Cys carbon peaks. In this approach, 1D {sup 13}C spectra were recorded at small temperature intervals for BPTI samples selectively labeled with site-specifically {sup 13}C-enriched Cys, and the recorded peaks were displayed in the order of the temperature after the spectral scales were normalized to a carbon peak. Over the profile of the line-shape, exchange broadening that altered with temperature was manifested for the carbon peaks of Cys14 and Cys38. The Cys14–Cys38 disulfide bond reportedly exists in equilibrium between a high-populated (M) and two low-populated states (m{sub c14} and m{sub c38}). Consistent with the three-site exchange model, biphasic exchange broadening arising from the two processes was observed for the peak of the Cys14 α-carbon. As the exchange broadening is maximized when the exchange rate equals the chemical shift difference in Hz between equilibrating sites, semi-quantitative information that was useful for establishing conditions for {sup 13}C relaxation dispersion experiments was obtained through the carbon line-shape profile. With respect to the m{sub c38} isomerization, the {sup 1}H-{sup 13}C signals at the β-position of the minor state were resolved from the major peaks and detected by exchange experiments at a low temperature.

  13. A 30 mK, 13.5 T scanning tunneling microscope with two independent tips

    Energy Technology Data Exchange (ETDEWEB)

    Roychowdhury, Anita [Laboratory for Physical Sciences, College Park, Maryland 20742 (United States); Center for Nanophysics and Advanced Materials, Department of Physics, University of Maryland, College Park, Maryland 20740 (United States); Gubrud, M. A.; Dana, R.; Dreyer, M. [Laboratory for Physical Sciences, College Park, Maryland 20742 (United States); Anderson, J. R.; Lobb, C. J.; Wellstood, F. C. [Center for Nanophysics and Advanced Materials, Department of Physics, University of Maryland, College Park, Maryland 20740 (United States)

    2014-04-15

    We describe the design, construction, and performance of an ultra-low temperature, high-field scanning tunneling microscope (STM) with two independent tips. The STM is mounted on a dilution refrigerator and operates at a base temperature of 30 mK with magnetic fields of up to 13.5 T. We focus on the design of the two-tip STM head, as well as the sample transfer mechanism, which allows in situ transfer from an ultra high vacuum preparation chamber while the STM is at 1.5 K. Other design details such as the vibration isolation and rf-filtered wiring are also described. Their effectiveness is demonstrated via spectral current noise characteristics and the root mean square roughness of atomic resolution images. The high-field capability is shown by the magnetic field dependence of the superconducting gap of Cu{sub x}Bi{sub 2}Se{sub 3}. Finally, we present images and spectroscopy taken with superconducting Nb tips with the refrigerator at 35 mK that indicate that the effective temperature of our tips/sample is approximately 184 mK, corresponding to an energy resolution of 16 μeV.

  14. A 30 mK, 13.5 T scanning tunneling microscope with two independent tips.

    Science.gov (United States)

    Roychowdhury, Anita; Gubrud, M A; Dana, R; Anderson, J R; Lobb, C J; Wellstood, F C; Dreyer, M

    2014-04-01

    We describe the design, construction, and performance of an ultra-low temperature, high-field scanning tunneling microscope (STM) with two independent tips. The STM is mounted on a dilution refrigerator and operates at a base temperature of 30 mK with magnetic fields of up to 13.5 T. We focus on the design of the two-tip STM head, as well as the sample transfer mechanism, which allows in situ transfer from an ultra high vacuum preparation chamber while the STM is at 1.5 K. Other design details such as the vibration isolation and rf-filtered wiring are also described. Their effectiveness is demonstrated via spectral current noise characteristics and the root mean square roughness of atomic resolution images. The high-field capability is shown by the magnetic field dependence of the superconducting gap of CuxBi2Se3. Finally, we present images and spectroscopy taken with superconducting Nb tips with the refrigerator at 35 mK that indicate that the effective temperature of our tips/sample is approximately 184 mK, corresponding to an energy resolution of 16 μeV.

  15. A computerized Langmuir probe system

    International Nuclear Information System (INIS)

    Pilling, L.S.; Bydder, E.L.; Carnegie, D.A.

    2003-01-01

    For low pressure plasmas it is important to record entire single or double Langmuir probe characteristics accurately. For plasmas with a depleted high energy tail, the accuracy of the recorded ion current plays a critical role in determining the electron temperature. Even for high density Maxwellian distributions, it is necessary to accurately model the ion current to obtain the correct electron density. Since the electron and ion current saturation values are, at best, orders of magnitude apart, a single current sensing resistor cannot provide the required resolution to accurately record these values. We present an automated, personal computer based data acquisition system for the determination of fundamental plasma properties in low pressure plasmas. The system is designed for single and double Langmuir probes, whose characteristics can be recorded over a bias voltage range of ±70 V with 12 bit resolution. The current flowing through the probes can be recorded within the range of 5 nA-100 mA. The use of a transimpedance amplifier for current sensing eliminates the requirement for traditional current sensing resistors and hence the need to correct the raw data. The large current recording range is realized through the use of a real time gain switching system in the negative feedback loop of the transimpedance amplifier

  16. A computerized Langmuir probe system

    Science.gov (United States)

    Pilling, L. S.; Bydder, E. L.; Carnegie, D. A.

    2003-07-01

    For low pressure plasmas it is important to record entire single or double Langmuir probe characteristics accurately. For plasmas with a depleted high energy tail, the accuracy of the recorded ion current plays a critical role in determining the electron temperature. Even for high density Maxwellian distributions, it is necessary to accurately model the ion current to obtain the correct electron density. Since the electron and ion current saturation values are, at best, orders of magnitude apart, a single current sensing resistor cannot provide the required resolution to accurately record these values. We present an automated, personal computer based data acquisition system for the determination of fundamental plasma properties in low pressure plasmas. The system is designed for single and double Langmuir probes, whose characteristics can be recorded over a bias voltage range of ±70 V with 12 bit resolution. The current flowing through the probes can be recorded within the range of 5 nA-100 mA. The use of a transimpedance amplifier for current sensing eliminates the requirement for traditional current sensing resistors and hence the need to correct the raw data. The large current recording range is realized through the use of a real time gain switching system in the negative feedback loop of the transimpedance amplifier.

  17. Application of a double-enrichment procedure for microsatellite isolation and the use of tailed primers for high throughput genotyping

    Directory of Open Access Journals (Sweden)

    Fábio Mendonça Diniz

    2007-03-01

    Full Text Available The number of microsatellite loci and their allelic diversity contribute to increase accuracy and informativity of genetic estimates, however, the isolation of microsatellite loci is not only laborious but also quite expensive. We used (GATAn and (GACAn tetranucleotide probes and single- and double-enrichment hybridization to construct and screen a genomic library with an increased proportion of DNA fragments containing repeat motifs. Repeats were found using both types of hybridization but the double-enrichment procedure recovered sequences of which 100% contained (GATAn and (GACAn motifs. Microsatellite loci primers were then designed with an M13R-tail or CAG-tag to produce scorable PCR products with minimal stutter. The approach used in this study suggests that double-enrichment is a worthwhile strategy when isolating repeat motifs from eukaryotic genomes. Moreover, the use of tailed microsatellite primers provides increased resolution for compound microsatellite loci, with a significant decrease in costs.

  18. Two new miniature inverted-repeat transposable elements in the genome of the clam Donax trunculus.

    Science.gov (United States)

    Šatović, Eva; Plohl, Miroslav

    2017-10-01

    Repetitive sequences are important components of eukaryotic genomes that drive their evolution. Among them are different types of mobile elements that share the ability to spread throughout the genome and form interspersed repeats. To broaden the generally scarce knowledge on bivalves at the genome level, in the clam Donax trunculus we described two new non-autonomous DNA transposons, miniature inverted-repeat transposable elements (MITEs), named DTC M1 and DTC M2. Like other MITEs, they are characterized by their small size, their A + T richness, and the presence of terminal inverted repeats (TIRs). DTC M1 and DTC M2 are 261 and 286 bp long, respectively, and in addition to TIRs, both of them contain a long imperfect palindrome sequence in their central parts. These elements are present in complete and truncated versions within the genome of the clam D. trunculus. The two new MITEs share only structural similarity, but lack any nucleotide sequence similarity to each other. In a search for related elements in databases, blast search revealed within the Crassostrea gigas genome a larger element sharing sequence similarity only to DTC M1 in its TIR sequences. The lack of sequence similarity with any previously published mobile elements indicates that DTC M1 and DTC M2 elements may be unique to D. trunculus.

  19. DNA probes

    Energy Technology Data Exchange (ETDEWEB)

    Castelino, J

    1993-12-31

    The creation of DNA probes for detection of specific nucleotide segments differs from ligand detection in that it is a chemical rather than an immunological reaction. Complementary DNA or RNA is used in place of the antibody and is labelled with {sup 32}P. So far, DNA probes have been successfully employed in the diagnosis of inherited disorders, infectious diseases, and for identification of human oncogenes. The latest approach to the diagnosis of communicable and parasitic infections is based on the use of deoxyribonucleic acid (DNA) probes. The genetic information of all cells is encoded by DNA and DNA probe approach to identification of pathogens is unique because the focus of the method is the nucleic acid content of the organism rather than the products that the nucleic acid encodes. Since every properly classified species has some unique nucleotide sequences that distinguish it from every other species, each organism`s genetic composition is in essence a finger print that can be used for its identification. In addition to this specificity, DNA probes offer other advantages in that pathogens may be identified directly in clinical specimens 10 figs, 2 tabs

  20. Hot and dense plasma probing by soft X-ray lasers

    Czech Academy of Sciences Publication Activity Database

    Krůs, Miroslav; Kozlová, Michaela; Nejdl, Jaroslav; Rus, B.

    2018-01-01

    Roč. 13, č. 1 (2018), č. článku C01004. ISSN 1748-0221. [International Symposium on Laser-Aided Plasma Diagnostics/18./. Prague, 24.09.2017-28.09.2017] R&D Projects: GA MŠk LM2010014; GA MŠk(CZ) LM2015083 Institutional support: RVO:61389021 Keywords : Plasma diagnostics - interferometry * spectroscopy and imaging * Plasma diagnostics - probes * Plasma generation (laser-produced, RF, x ray-produced) Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/13/01/C01004