WorldWideScience

Sample records for m-shell x-ray production

  1. Differential and total M-shell X-ray production cross-sections of some selected elements between Au and U at 5.96 keV

    International Nuclear Information System (INIS)

    Ozdemir, Yueksel

    2007-01-01

    Differential M-shell X-ray production (MXRP) cross-sections for selected heavy elements between Au and U have been measured at 5.59 keV incident photon energy, respectively at seven angles varying from 120 o to 150 o a Si(Li) detector. The differential M-shell X-ray production cross-sections have been derived, using M-shell fluorescence yields, experimental total M X-ray production cross-sections and theoretical M-shell photoionization cross-sections. The differential M-shell X-ray production cross-sections have been compared with the semi-empirical fits. The measured differential M X-ray production cross-sections have been found within experimental error. Differential M X-ray production cross-section can be fitted to the Σ n a n Z n (n = 2) as a function of cos θ. Total M X-ray production cross-sections have been derived using the fitted values

  2. K-, L- and M-shell X-ray productions induced by argon ions in the 0.8–1.6 MeV/amu range

    Energy Technology Data Exchange (ETDEWEB)

    Gluchshenko, N.; Gorlachev, I. [Institute of Nuclear Physics, Ibragimov 1, 050032, Almaty (Kazakhstan); Ivanov, I. [Institute of Nuclear Physics, Ibragimov 1, 050032, Almaty (Kazakhstan); L.N. Gumilyov Eurasian National University, Mirzoyan 2, Astana (Kazakhstan); Kireyev, A. [Institute of Nuclear Physics, Ibragimov 1, 050032, Almaty (Kazakhstan); Kozin, S.; Kurakhmedov, A. [Institute of Nuclear Physics, Ibragimov 1, 050032, Almaty (Kazakhstan); L.N. Gumilyov Eurasian National University, Mirzoyan 2, Astana (Kazakhstan); Platov, A. [Institute of Nuclear Physics, Ibragimov 1, 050032, Almaty (Kazakhstan); Zdorovets, M. [Institute of Nuclear Physics, Ibragimov 1, 050032, Almaty (Kazakhstan); Ural Federal University, 620002, Yekaterinburg (Russian Federation)

    2016-04-01

    The X-ray emissions induced by argon ions for the elements from Mg to Bi were measured on mono-elemental thin films. K-, L- and M-shells X-ray production cross section were obtained for the {sup 40}Ar projectile energies of 32, 40, 48, 56 and 64 MeV, considering absorption corrections. For the most of target elements the approach used is based on the calculation of X-ray production cross sections through the cross section of Rutherford backscattering. The efficiency of the X-ray detector was determined using standard calibrated radioactive sources. The experimental results are compared to the predictions of the ECPSSR and PWBA theories calculated with the ISICS code.

  3. K-, L- and M-shell X-ray productions induced by oxygen ions in the 0.8–1.6 MeV/amu range

    Energy Technology Data Exchange (ETDEWEB)

    Gorlachev, I., E-mail: Igor.Gorlachev@gmail.com [Institute of Nuclear Physics, 050032 Ibragimov 1, Almaty (Kazakhstan); Gluchshenko, N. [Institute of Nuclear Physics, 050032 Ibragimov 1, Almaty (Kazakhstan); Ivanov, I. [Institute of Nuclear Physics, 050032 Ibragimov 1, Almaty (Kazakhstan); L.N. Gumilyov Eurasian National University, Mirzoyan 2, Astana (Kazakhstan); Kireyev, A. [Institute of Nuclear Physics, 050032 Ibragimov 1, Almaty (Kazakhstan); Kozin, S.; Kurakhmedov, A. [Institute of Nuclear Physics, 050032 Ibragimov 1, Almaty (Kazakhstan); L.N. Gumilyov Eurasian National University, Mirzoyan 2, Astana (Kazakhstan); Platov, A. [Institute of Nuclear Physics, 050032 Ibragimov 1, Almaty (Kazakhstan); Zdorovets, M. [Institute of Nuclear Physics, 050032 Ibragimov 1, Almaty (Kazakhstan); Ural Federal University, Yekaterinburg 620002 (Russian Federation)

    2016-08-15

    The X-ray production cross sections induced by oxygen ions with projectile energies from 12.8 to 25.6 MeV for the elements from Al to Bi were measured. The applied approach is based on calculation of X-ray production cross sections through the cross section of Rutherford backscattering, which can be calculated with high accuracy using the Rutherford formula. The experimental results are compared to the predictions of ECPSSR and PWBA theories calculated with the ISICS code.

  4. M-shell X-ray production cross-sections for elements with 67 ≤ Z ≤ 92 at incident photon energies EM1inc≤150keV

    International Nuclear Information System (INIS)

    Chauhan, Yogeshwar; Kumar, Anil; Puri, Sanjiv

    2009-01-01

    The X-ray production cross-sections for the Mk (k = ξ, δ, α, β, ζ, γ, m 1 and m 2 ) groups of X-rays have been evaluated for all the elements with 67 ≤ Z ≤ 92 at incident photon energies ranging E M 1 inc ≤150 keV using currently available theoretical data sets of different physical parameters, namely, partial photoionization cross-sections, X-ray emission rates, fluorescence and Coster-Kronig yields, and the K-shell/L j (j = 1-3) subshell to the M i (i = 1-5) subshell vacancy transfer probabilities, based on the independent particle models.

  5. X ray Production. Chapter 5

    Energy Technology Data Exchange (ETDEWEB)

    Nowotny, R. [Medical University of Vienna, Vienna (Austria)

    2014-09-15

    The differential absorption of X rays in tissues and organs, owing to their atomic composition, is the basis for the various imaging methods used in diagnostic radiology. The principles in the production of X rays have remained the same since their discovery. However, much refinement has gone into the design of X ray tubes to achieve the performance required for today’s radiological examinations. In this chapter, an outline of the principles of X ray production and a characterization of the radiation output of X ray tubes will be given. The basic processes producing X rays are dealt with in Section 1.4.

  6. Equipment, components and production of x-ray

    International Nuclear Information System (INIS)

    Idris Besar

    2004-01-01

    The contents of this chapter are follows - Equipment, Components and Production of x-Ray: x-ray system, generator, control panel. x-ray tube, cathode, anode, envelope, housing, collimator, other components, x-ray production, Bremsstrahlung x-ray, characteristic x-ray, heat production

  7. Electron-impact-induced K plus M shell ionization in solid targets of medium-Z elements studied by means of high-resolution x-ray spectroscopy

    International Nuclear Information System (INIS)

    Ludziejewski, T.; Rymuza, P.; Sujkowski, Z.; Borchert, G.; Dousse, J.; Rheme, C.; Polasik, M.

    1996-01-01

    The Kβ 2 x-ray spectra of zirconium, niobium, molybdenum, and palladium bombarded by 150 and 300 keV electrons were measured with a high-resolution transmission curved crystal spectrometer. Multiconfiguration Dirac-Fock calculations were used for the decomposition of the experimental spectra into the Kβ 2 M 0 (diagram) and Kβ 2 M 1 (satellite) components. The probabilities of energy dependent (direct Coulomb and two-step) processes were estimated from the differences in the satellite line yields for electrons and photons. The satellite yields are found to be considerably enhanced in comparison with those for the proton-induced ionization recently measured and analyzed in the same way [T. Ludziejewski et al., Phys. Rev. A 52, 2791 (1995)]. This result indicates the importance of multielectron effects in the K plus M shell ionization by energetic projectiles. copyright 1996 The American Physical Society

  8. Target for production of X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Korenev, S.A. E-mail: sergey_korenev@steris.com

    2004-10-01

    The patented new type of X-ray target is considered in this report. The main concept of the target consists in developing a sandwich structure depositing a coating of materials with high Z on the substrate with low Z, high thermal conductivity and high thermal stability. The target presents multiple layers system. The thermal conditions for X-ray target are discussed. The experimental results for Ta target on the Al and Cu substrates are presented.

  9. Target for production of X-rays

    International Nuclear Information System (INIS)

    Korenev, S.A.

    2004-01-01

    The patented new type of X-ray target is considered in this report. The main concept of the target consists in developing a sandwich structure depositing a coating of materials with high Z on the substrate with low Z, high thermal conductivity and high thermal stability. The target presents multiple layers system. The thermal conditions for X-ray target are discussed. The experimental results for Ta target on the Al and Cu substrates are presented

  10. Target for production of X-rays

    Science.gov (United States)

    Korenev, S. A.

    2004-09-01

    The patented new type of X-ray target is considered in this report. The main concept of the target consists in developing a sandwich structure depositing a coating of materials with high Z on the substrate with low Z, high thermal conductivity and high thermal stability. The target presents multiple layers system. The thermal conditions for X-ray target are discussed. The experimental results for Ta target on the Al and Cu substrates are presented.

  11. Production of enterotoxin by Salmonella exposed to X rays

    International Nuclear Information System (INIS)

    Szulc, M.; Pliszka, A.; Peconek, J.

    1982-01-01

    The influence of irradiation on enterotoxin production by Salmonella enteritidis and S. typhimurium was evaluated using skin test elaborated by Tschaepe and others. The strains examined appeared to be equally sensitive to X rays. A dose of 100 Gy decreased the number of bacterial cells at approx. 10 D 10 and 200 Gy at 2-3 D 10 . Irradiation with 100 and 200 Gy of X rays did not influence enterotoxin production by microorganisms which were resistant to the process of irradiation. (author)

  12. The safety of food products requires X-ray testing

    International Nuclear Information System (INIS)

    Lardiere, C.

    2017-01-01

    Food safety through standards and regulations imposes food products to be tested for the presence of alien elements. So far metal detectors have been used to detect metal parts, now they have been progressively replaced with X-ray scanners that allow the detection of a lot more contaminants. The improvement of algorithms for image processing combined with the availability of ever more powerful PC have led to the routine use of X-ray testing on industrial processes. Technological progress has made X-ray testing more efficient: while previously a power of 500 W was necessary to cross a 10 cm thickness of water, now only 100 W is necessary. The main advantage of X-ray testing is to be able to test food even packed in metal containers and to detect if the container is deformed. Another advantages is to be able to detect a lot of elements like pieces of glass, small stones or bits of bones. The minimal size to be detected is 0.5 mm for stainless steels and 2 mm for glass or bones. Usually metal detectors are set at the end of the production line just before packaging but in some cases they can be included in the line in order to protect the next machine that intervenes to process the food. (A.C.)

  13. Double K-vacancy production by x-ray photoionization

    International Nuclear Information System (INIS)

    Southworth, S. H.; Dunford, R. W.; Kanter, E. P.; Krassig, B.; Young, L.; Armen, G. B.; Levin, J. C.; Chen, M. H.; Ederer, D. L.

    2002-01-01

    We have studied double K-shell photoionization of Ne and Mo (Z = 10 and 42) at the Advanced Photon Source. Double K-vacancy production in Ne was observed by recording the KK-KLL Auger hypersatellite spectrum. Comparison is made with calculations using the multiconfiguration Dirac-Fock method. For Mo, double K-vacancy production was observed by recording the Kα, β fluorescence hypersatellite and satellite x rays in coincidence. From the intensities of the Auger or x-ray hypersatellites relative to diagram lines, the probabilities for double K-vacancy production relative to single K-vacancies were determined. These results, along with reported measurements on other atoms, are compared with Z-scaling calculations of the high-energy limits of the double-to-single K-shell photoionization ratio

  14. Application of x-ray residual stress measurement to products

    International Nuclear Information System (INIS)

    Goto, T.; Iwamura, T.

    1975-01-01

    The X-ray residual stress measuring method is the only nondestructive method for measuring residual stress in polycrystalline materials. It is capable of obtaining information not only on macroscopic stress but also microscopic stress. The authors are employing this method for the development of pre-service and in-service inspection methods and for the improvement of various manufacturing techniques. In this paper, the results of measurement of some products as examples of its application are described. The examples introduced concern the following: (1) Selection of optimum conditions in heat treatment and stress-relief treatment. (2) Residual stress produced by mechanical processes such as autofrettage and flow form. (3) Check of manufacturing processes of rotary shaft and welded parts. (4) Estimation of fatigue strength of shot-peened part. (5) Detection of fatigue damage of shot-peened part. (auth.)

  15. Measurement of angular dependence of M X-ray production cross-sections in Re, Bi and U at 5.96 keV

    International Nuclear Information System (INIS)

    Apaydin, G.; Tirasoglu, E.; Sogut, O.

    2008-01-01

    The M X-ray production differential cross sections in Re, Bi and U elements have been measured at the 5.96 keV incident photon energy in an angular range 135 - 155 degrees. The measurements were performed using a Fe 55 source and a Si(Li) detector. It appears that, after photoionization of inner shells, the vacancy state has equal population of magnetic substates and the subsequent X-ray emission is isotropic. Total M X-ray production cross sections from the decay at the 5.96 keV photon energies are found to be in good agreement with the calculated theoretical results using the theoretical values of M shell photoionization cross section. (authors)

  16. High-energy X-ray production in a boundary layer of an accreting neutron star

    International Nuclear Information System (INIS)

    Hanawa, Tomoyuki

    1991-01-01

    It is shown by Monte Carlo simulation that high-energy X-rays are produced through Compton scattering in a boundary layer of an accreting neutron star. The following is the mechanism for the high-energy X-ray production. An accreting neutron star has a boundary layer rotating rapidly on the surface. X-rays radiated from the star's surface are scattered in part in the boundary layer. Since the boundary layer rotates at a semirelativistic speed, the scattered X-ray energy is changed by the Compton effect. Some X-rays are scattered repeatedly between the neutron star and the boundary layer and become high-energy X-rays. This mechanism is a photon analog of the second-order Fermi acceleration of cosmic rays. When the boundary layer is semitransparent, high-energy X-rays are produced efficiently. 17 refs

  17. K X-Ray production cross sections for 40-180 keV protons

    International Nuclear Information System (INIS)

    Szegedi, S.; Hassan, M.F.

    2002-01-01

    In view of the importance of the X-ray production cross-section for the determination of element concentration in a given material, we have measured them experimentally for light elements Sc and Fe using proton beams of energy between 40 and 180 keV. The obtained K X-ray production cross-section is compared with the previous experimental results. The experimental K X-ray production cross-section for proton induced X-ray emission (PIXE) analysis, using low energy (200 keV) accelerator, have been improved

  18. Atomic x-ray production by relativistic heavy ions

    International Nuclear Information System (INIS)

    Ioannou, J.G.

    1977-12-01

    The interaction of heavy ion projectiles with the electrons of target atoms gives rise to the production, in the target, of K-, L- or higher shell vacancies which are in turn followed by the emission of characteristic x-rays. The calculation of the theoretical value of the K- and L-shells vacancy production cross section was carried out for heavy ion projectiles of any energy. The transverse component of the cross section is calculated for the first time in detail and extensive tables of its numerical value as a function of its parameters are also given. Experimental work for 4.88 GeV protons and 3 GeV carbon ions is described. The K vacancy cross section has been measured for a variety of targets from Ti to U. The agreement between the theoretical predictions and experimental results for the 4.88 GeV protons is rather satisfactory. For the 3 GeV carbon ions, however, it is observed that the deviation of the theoretical and experimental values of the K vacancy production becomes larger with the heavier target element. Consequently, the simple scaling law of Z 1 2 for the cross section of the heavy ion with atomic number Z 1 to the proton cross section is not true, for the K-shell at least. A dependence on the atomic number Z 2 of the target of the form (Z 1 - αZ 2 ) 2 , instead of Z 1 2 , is found to give extremely good agreement between theory and experiment. Although the exact physical meaning of such dependence is not yet clearly understood, it is believed to be indicative of some sort of screening effect of the incoming fast projectile by the fast moving in Bohr orbits K-shell electrons of the target. The enhancement of the K-shell ionization cross section by relativistic heavy ions on heavy targets is also discussed in terms of its practical applications in various branches of science and technology

  19. K,L X-rays production cross sections for 1H and 4He

    International Nuclear Information System (INIS)

    Heitz, C.; Costa, G.J.; Cailleret, J.; Lagarde, G.

    1982-01-01

    Experimental X-ray production cross sections are tabulated for 1 H and 4 He projectiles. In the case of K X-rays, a comparison with theoretical values is also performed in view of applications, such a PIXE analysis [fr

  20. Thermal x-rays and deuterium production in stellar flares

    International Nuclear Information System (INIS)

    Colgate, S.A.

    1977-01-01

    The x-ray spectrum of flares is shown to be necessarily thermal up to greater than or equal to 200 keV because the self magnetic field of any electron stream required for a thick or thin target source is inconsistently large. The resulting flare model can then be related to stellar luminosity, convection and magnetic fields to result in a maximum possible γ-burst (Mullan, 1976) and continuous x-ray flux. One of the most striking isotopic anomalies observed is the extreme enrichment of Helium (3) in some solar flares and the mysterious depletion of deuterium. It is discussed how deuterium may be produced and emitted in the largest flares associated with γ-bursts but in amounts insufficient to support the tentative conclusion of Colemen and Worden

  1. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Gursky, H.

    1974-01-01

    This text contains ten chapters and three appendices. Following an introduction, chapters two through five deal with observational techniques, mechanisms for the production of x rays in a cosmic setting, the x-ray sky and solar x-ray emission. Chapters six through ten include compact x-ray sources, supernova remnants, the interstellar medium, extragalactic x-ray sources and the cosmic x-ray background. Interactions of x rays with matter, units and conversion factors and a catalog of x-ray sources comprise the three appendices. (U.S.)

  2. Production of X-rays by inverse Compton effect

    International Nuclear Information System (INIS)

    Mainardi, R.T.

    2005-01-01

    X-rays and gamma rays of high energy values can be produced by the scattering of low energy photons with high energy electrons, being this a process controlled by the Compton scattering. If a laser beam is used, the x-ray beam inherits the properties of intensity, monochromaticity and collimation from the laser. In this work we analyze the generation of intense x-ray beams of energies between 10 and 100 KeV to be used in a wide range of applications where a high intensity and high degrees of monochromaticity and polarization are important properties to improve image reduce doses and improve radiation treatments. To this purpose we evaluated, using relativistic kinematics the scattered beam properties in terms of the scattering angle. This arrangement is being considered in several worldwide laboratories as an alternative to synchrotron radiation and is referred to as 'table top synchrotron radiation', since it cost of installation is orders of magnitude smaller than a 'synchrotron radiation source'. The radiation beam might exhibit non-linear properties in its interaction with matter, in a similar way as a laser beam and we will investigate how to calibrate and evaluate TLD dosemeters properties, both in low and high intensity fields either mono or polyenergetic in wide spectral energy ranges. (Author)

  3. X-ray irradiation on blood products for the purpose of prevention of PT-GVHD

    International Nuclear Information System (INIS)

    Tayama, Tatsuya; Naohara, Tooru; Haneda, Kenji; Juji, Takeo.

    1990-01-01

    X-ray irradiation on blood products is a common method to prevent the risk of inducing PT-GVHD, and has recently become to be used in Japan. We have tried X-ray irradiation on WB, CRC and PC using HITACHI X-ray Irradiation Apparatus MBR1520R, and studied its practical usefulness. In case of irradiation on blood bags as the minimum dose of 1,500 rads, these conditions are thought to be practical: 1) the use of 1.0 mm Al filter, 2) the distance of 550 nm from X-ray source, and 3) irradiation on 4 bags at the same time. But, it has also been noticed that total doses and qualities of X-ray absorbed into blood were different between upper and lower side of the bag. Bloods on upper side absorbed much doses and a wide range of X-ray, on the other hand, bloods on lower side absorbed less doses and hard X-ray. In these conditions, irradiated lymphocytes showed a complete inhibition of thymidine uptake in MLC test, still had 15% of activity in PHA stimulation. The qualities of other blood components have not changed before and after irradiation. X-ray irradiation is useful in a routine work of blood center, but problems of proper doses and a uniformity of irradiation are remained to be solved. (author)

  4. X-ray production experiments on the RACE Compact Torus Accelerator

    International Nuclear Information System (INIS)

    Hammer, J.H.; Eddleman, J.L.; Hartman, C.W.; McLean, H.S.; Molvik, A.W.; Gee, M.

    1989-12-01

    The Purpose of the Compact Torus Accelerator (CTA) program at LLNL is to prove the principle of a unique accelerator concept based on magnetically confined compact torus (CT) plasma rings and to study applications. Successful achievement of these goals could lead to a high power-density driver for many applications including an intense x-ray source for nuclear weapons effects simulation and an inertial fusion driver. Fusion applications and a description of the CTA concept are included in a companion paper at this conference. This paper will describe the initial experiments on soft x-ray production conducted on the plasma Ring ACcelerator Experiment (RACE) and compare the results to modeling studies. The experiments on CT stagnation and soft x-ray production were conducted with unfocused rings as a first of CT dynamics and the physics of x-ray production. The x-ray fluences observed are consistent with expectations based on calculations employing a radiation-hydrodynamics code. We conclude with a diffusion of future x-ray production studies that can be conducted on RACE and a possible multi-megajoule upgrade

  5. Simulation of intense laser-dense matter interactions. X-ray production and laser absorption

    Energy Technology Data Exchange (ETDEWEB)

    Ueshima, Yutaka; Kishimoto, Yasuaki; Sasaki, Akira [Japan Atomic Energy Research Inst., Neyagawa, Osaka (Japan). Kansai Research Establishment; Sentoku, Yasuhiko; Tajima, Toshiki

    1998-03-01

    The development of short-pulse ultra high intensity lasers will enable us to generate short-pulse intense soft and hard X-rays. Acceleration of an electron in laser field generates intense illuminated located radiation, Larmor radiation, around KeV at 10{sup 18} W/cm{sup 2} with 100 TW and 1 {mu}m wave length laser. The Coulomb interaction between rest ions and relativistic electron generates broad energy radiation, bremsstrahlung emission, over MeV at 10{sup 18} W/cm{sup 2} with the same condition. These intense radiations come in short pulses of the same order as that of the irradiated laser. The generated intense X-rays, Larmor and bremsstrahlung radiation, can be applied to sources of short pulse X-ray, excitation source of inner-shell X-ray laser, position production and nuclear excitation, etc. (author)

  6. The effect of target thickness on x-ray production by FXR [Flash X-Ray Machine

    International Nuclear Information System (INIS)

    Back, N.L.

    1986-01-01

    The electron-photon transport code SANDYL has been used to calculate the x-ray flux for a simplified Flash X-Ray Machine (FXR) bullnose geometry. Four different thicknesses (24.5, 36.75, 49, and 61.25 mils) were used for the tantalum bremsstrahlung target in order to study the effect of target thickness on the FXR output. The calculations were performed for a parallel 17 MeV electron beam, and the resulting angular distributions were then used to compute the forward flux for the more realistic case of a converging beam. Over the range of thicknesses studied, the x-ray energy content per steradian on axis was essentially independent of target thickness. The main reason for this is that, while the total x-ray flux coming out of the target increases with increasing target thickness, the angular width of that flux also increases. The implications for target wheel design are discussed. 3 refs., 7 figs

  7. Yeast cell metabolism investigated by CO{_2} production and soft X-ray irradiation

    Science.gov (United States)

    Masini, A.; Batani, D.; Previdi, F.; Milani, M.; Pozzi, A.; Turcu, E.; Huntington, S.; Takeyasu, H.

    1999-01-01

    Results obtained using a new technique for studying cell metabolism are presented. The technique, consisting in CO2 production monitoring, has been applied to Saccharomyces cerevisiae yeast cells. Also the cells were irradiated using the soft X-ray laser-plasma source at Rutherford Appleton Laboratory with the aim of producing a damage of metabolic processes at the wall level, responsible for fermentation, without great interference with respiration, taking place in mitochondria, and DNA activity. The source was calibrated with PIN diodes and X-ray spectrometers and used Teflon stripes as target, emitting X-rays at about 0.9 keV, with a very low penetration in biological material. X-ray doses delivered to the different cell compartments were calculated following a Lambert-Bouguet-Beer law. Immediately after irradiation, the damage to metabolic activity was measured again by monitoring CO2 production. Results showed a general reduction in gas production by irradiated samples, together with non-linear and non-monotone response to dose. There was also evidence of oscillations in cell metabolic activity and of X-ray induced changes in oscillation frequency.

  8. Determination of fission products in irradiated fuel by X-ray fluorescence

    International Nuclear Information System (INIS)

    Mogensen, M.; Als-Nielsen, J.; Hessel Andersen, N.

    1986-08-01

    X-ray fluorescence is a well established analytical tool for measuring elemental composition of fairly large (approximately 5 cm 2 ) ''cold'' samples. A version of this technique has been developed for analysis of radial distribution of fission products Xe, Cs and Ba in irradiated UO 2 fuel samples. About 0.1 mm thin slices of fuel pellets (full cross sections) are irradiated by 50 keV X-rays. The intensity of the Xe (Cs, Ba) K α fluorescence radiation generated is measured by means of a Ge detector fitted with a collimator. The slit is 0.5 mm wide in the scanning direction and 2 mm long. The measured Xe K α X-ray intensities are converted to absolute concentrations by comparing to the intensity from a Xe gas standard. In the case of Cs and Ba solid standards may be used. The X-ray fluorescence analysis is compared to other techniques used to obtain radial fission product profiles. It is shown how a combination of X-ray fluorescence and electron probe micro analysis is able to reveal the amount of Xe in the grain boundary porosities. (author)

  9. X-ray fluorescence analysis of low concentrations metals in geological samples and technological products

    Science.gov (United States)

    Lagoida, I. A.; Trushin, A. V.

    2016-02-01

    For the past several years many nuclear physics methods of quantitative elemental analysis have been designed. Many of these methods have applied in different devices which have become useful and effective instrument in many industrial laboratories. Methods of a matter structure analysis are based on the intensity detection of the X-ray radiation from the nuclei of elements which are excited by external X-ray source. The production of characteristic X-rays involves transitions of the orbital electrons of atoms in the target material between allowed orbits, or energy states, associated with ionization of the inner atomic shells. One of these methods is X-ray fluorescence analysis, which is widespread in metallurgical and processing industries and is used to identify and measure the concentration of the elements in ores and minerals on a conveyor belt. Samples of copper ore with known concentrations of elements, were taken from the Ural deposit. To excite the characteristic X-rays radionuclide sources 109Cd, with half-life 461.4 days were used. After finding the calibration coefficients, control measurements of samples and averaging of overall samples were made. The measurement error did not exceed 3%.

  10. Production of transform-limited X-ray pulses through self-seeding at the European X-ray FEL

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2011-09-15

    An important goal for any advanced X-ray FEL is an option for providing Fourier-limited X-ray pulses. In this way, no monochromator is needed in the experimental hall. Self-seeding is a promising approach to significantly narrow the SASE bandwidth to produce nearly transform-limited pulses. These are important for many experiments including 3D diffraction imaging.We discuss the implementation of a single-crystal self-seeding scheme in the hard X-ray lines of the European XFEL. For this facility, transform-limited pulses are particularly valuable since they naturally support the extraction of more FEL power than at saturation by exploiting tapering in the tunable-gap baseline undulators. Tapering consists of a stepwise change of the undulator gap from segment to segment. Based on start-to-end simulations dealing with the up-to-date parameters of the European XFEL, we show that the FEL power reaches about 400 GW, or one order of magnitude higher power than the SASE saturation level (20 GW). This analysis indicates that our self-seeding scheme is not significantly affected by non-ideal electron phase-space distribution, and yields about the same performance as in the case for an electron beam with ideal parameters. The self-seeding scheme with a single crystal monochromator is extremely compact (about 5 m long), and cost estimations are low enough to consider adding it to the European XFEL capabilities from the very beginning of the operation phase. (orig.)

  11. Production of transform-limited X-ray pulses through self-seeding at the European X-ray FEL

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2011-09-01

    An important goal for any advanced X-ray FEL is an option for providing Fourier-limited X-ray pulses. In this way, no monochromator is needed in the experimental hall. Self-seeding is a promising approach to significantly narrow the SASE bandwidth to produce nearly transform-limited pulses. These are important for many experiments including 3D diffraction imaging.We discuss the implementation of a single-crystal self-seeding scheme in the hard X-ray lines of the European XFEL. For this facility, transform-limited pulses are particularly valuable since they naturally support the extraction of more FEL power than at saturation by exploiting tapering in the tunable-gap baseline undulators. Tapering consists of a stepwise change of the undulator gap from segment to segment. Based on start-to-end simulations dealing with the up-to-date parameters of the European XFEL, we show that the FEL power reaches about 400 GW, or one order of magnitude higher power than the SASE saturation level (20 GW). This analysis indicates that our self-seeding scheme is not significantly affected by non-ideal electron phase-space distribution, and yields about the same performance as in the case for an electron beam with ideal parameters. The self-seeding scheme with a single crystal monochromator is extremely compact (about 5 m long), and cost estimations are low enough to consider adding it to the European XFEL capabilities from the very beginning of the operation phase. (orig.)

  12. Bragg transmission phase plates for the production of circularly polarized x-rays

    International Nuclear Information System (INIS)

    Lang, J.C.; Srajer, G.

    1994-01-01

    A thin-crystal Si (400) Bragg transmission x-ray phase plate has been constructed for the production of 5 to 12 keV circularly polarized x-rays. Using multiple beam diffraction from a GaAs crystal, a direct measurement of the degree of circular polarization as a function of off-Bragg position was made. These measurements indicated nearly complete circular polarization (|P c | ≥ 0.95) and full helicity reversal on opposite sides of the rocking curve

  13. Production of Coherent xuv and soft-x-ray light using a transverse optical klystron

    International Nuclear Information System (INIS)

    Kincaid, B.M.; Freeman, R.R.

    1984-01-01

    This section describes the theory of the production of coherent xuv radiation and soft x rays using a transverse optical klystron (TOK). A TOK uses a high-power laser in conjunction with an undulator magnet to produce laserlike output of xuv radiation from a relativistic electron beam. 16 references, 5 figures

  14. The design of management system guidelines and technical standards for the production of x-ray aircraft

    International Nuclear Information System (INIS)

    Dyah Palupi; Made Pramayuni

    2013-01-01

    Concept of management systems guidelines and technical standards X-ray Equipment Production arranged in order to prepare for the effective and efficient regulatory to ensure the safety of X-ray equipment production in Indonesia. The regulatory tools may the government policy or regulations. Authors proposed that BAPETEN develop guidelines for management system of x-ray equipment production by combining ISO 13485 with BAPETEN Chairman Regulation no.4 /2010. Author also suggested that BAPETEN make technical standards IEC 60601 as a mandatory standard in producing x-ray equipment. (author)

  15. Analytical formulas for calculation of K X-ray production cross sections by alpha ions

    International Nuclear Information System (INIS)

    Abdellatif, A.; Kahoul, A.; Deghfel, B.; Nekkab, M.; Medjadi, D.E.

    2012-01-01

    In the present study, different procedures are followed to deduce the semi-empirical and the empirical K X-rayX-ray production cross sections induced by alpha ions from the available experimental data and the theoretical results of the ECPSSR model for elements with 20≤Z≤30. The deduced K X-ray production cross sections are compared with predictions from ECPSSR model and with other earlier works. Generally, the deduced K X-ray production cross sections obtained by fitting the available experimental data for each element separately give the most reliable values than those obtained by a global fit. - Highlights: ► The results were presented for elements with atomic numbers 20≤Z≤30 by alpha impact. ► The present semi-empirical formulas were derived from both theoretical and experimental values. ► The available experimental data are directly fitted to deduce the empirical one. ► The results obtained for each element separately give the most reliable values than those obtained by a global fit. ► This procedure is proposed as a black-box way to quickly estimate the cross section.

  16. Determination of Fission Products in Irradiated Fuel by X-Ray Fluorescence

    DEFF Research Database (Denmark)

    Mogensen, Mogens Bjerg; Als-Nielsen, Jens Aage; Andersen, Niels Hessel

    X-ray fluorescence i s a well e s t a b l i s h e d analytical tool for measuring elemental composition of fairly large (~ 5 cm2) "cold" samples. A version of t h i s technique has been developed for a n a l y s i s of radial d i s t r i b u t i o n of f i s s i o n products Xe, Cs and Ba...... in the scanning d i rection and 2 mm long. The measured Xe Ko x-ray i n t e n s i t i e s are converted to absolute concentrations by comparing to the intens i t y from a Xe gas standard. In the case of Cs and Ba s o l id standards may be used. The X-ray fluorescence analysis i s compared to other techniques used...... to obtain radial f i s s i o n product profiles, i t i s shown how a combination of X-ray fluorescence and electron probe micro a n a l y s i s i s able to reveal the amount of Xe in the grain boundary porosities....

  17. Suzaku Reveals Helium-burning Products in the X-Ray-emitting Planetary Nebula BD +30 3639

    Science.gov (United States)

    Murashima, M.; Kokubun, M.; Makishima, K.; Kotoku, J.; Murakami, H.; Matsushita, K.; Hayashida, K.; Arnaud, K.; Hamaguchi, K.; Matsumoto, H.

    2006-08-01

    BD +30 3639, the brightest planetary nebula at X-ray energies, was observed with Suzaku, an X-ray observatory launched on 2005 July 10. Using the X-ray Imaging Spectrometer, the K lines from C VI, O VII, and O VIII were resolved for the first time, and the C/O, N/O, and Ne/O abundance ratios were determined. The C/O and Ne/O abundance ratios exceed the solar value by factors of at least 30 and 5, respectively. These results indicate that the X-rays are emitted mainly by helium-shell-burning products.

  18. Flash X-ray

    International Nuclear Information System (INIS)

    Sato, Eiichi

    2003-01-01

    Generation of quasi-monochromatic X-ray by production of weakly ionized line plasma (flash X-ray), high-speed imaging by the X-ray and high-contrast imaging by the characteristic X-ray absorption are described. The equipment for the X-ray is consisted from the high-voltage power supply and condenser, turbo molecular pump, and plasma X-ray tube. The tube has a long linear anticathode to produce the line plasma and flash X-ray at 20 kA current at maximum. X-ray spectrum is measured by the imaging plate equipped in the computed radiography system after diffracted by a LiF single crystal bender. Cu anticathode generates sharp peaks of K X-ray series. The tissue images are presented for vertebra, rabbit ear and heart, and dog heart by X-ray fluoroscopy with Ce anticathode. Generation of K-orbit characteristic X-ray with extremely low bremsstrahung is to be attempted for medical use. (N.I.)

  19. Zinc content determination in rice and other agricultural products by X-ray fluorescence

    International Nuclear Information System (INIS)

    Denis Alpizar, Otoniel; Diaz Rizo, Oscar

    2010-01-01

    The Zn content in regular consumption foodstuff (rice, some vegetables and roots) in Cuba is reported. Concentrations are determined by X-Ray Fluorescence analysis using a set of organic standards doped with Zn. The accuracy of the analytical procedure was validated using the Certified Reference Materials IAEA 393 and y MA-B-3/TM. The obtained results show rice as the major Zn bioaccumulator of the studied agricultural products and the main Zn source in Cuban human diet. (author)

  20. Interaction of x-rays and food pyrolysis products in producing oncogenic transformation in vitro

    International Nuclear Information System (INIS)

    Borek, C.; Ong, A.

    1981-01-01

    In recent years it has become evident from epidemiological and experimental data that a large number of environmental factors, including diet, play a role in modifying the incidence of cancer. Cell culture systems in which oncogenic transformation serves as an end point are powerful tools for evaluating these questions. Using such systems it has been shown recently that pyrolysis products from charred surfaces of broiled meat and fish can transform hamster embryo cells in vitro as well as produce tumors in the animal. Our studies in vitro have demonstrated the oncogenic potential of ionizing radiation in both hamster and human cells and have established in hamster cells the dose response relationship at doses ranging from 1 to 600 rad for x-rays and 0.1 to 150 rad for neutrons. The present work was aimed at evaluating whether there exists a cocarcinogenic interaction between a pyrolysis product and x-rays in their ability to transform hamster embryo cells in vitro. We have found that when cells are exposed to x-rays prior to treatment with the pyrolysis product there appears to be a synergistic interaction between the two agents in their ability to transform the cells

  1. Gamma and X-rays Production for Experiments at ELSA Facility

    CERN Document Server

    Lemaire, J

    2004-01-01

    The ELSA facility is a high brightness 18 MeV electron source dedicated to electron radiation, gamma-rays and picosecond hard and soft X-rays. It consists of a 144 MHz RF photoinjector producing short bunches which are further accelerated to a final energy varying from 2 to 18 MeV thanks to three 433 MHz RF cavities. Former beam compression design used a half turn magnet compressor system. It has been recently replaced by a double alpha magnet compressor. Electron beams are now delivered to a new experimental room. We present the new panel of interests offered by this facility in term of gamma-ray and X-ray production.

  2. X-ray flares from runaway pair production in active galactic nuclei

    Science.gov (United States)

    Kirk, J. G.; Mastichiadis, A.

    1992-01-01

    The hard X-ray spectrum of AGNs is nonthermal, probably arising from an electron-positron pair cascade, with some emission reflected off relatively cold matter. There has been interest in models on which protons are accelerated and create relativistic electrons on interaction with a local radiation field. It is shown here that a sufficient column density of protons can lead to runaway pair production: photons generated by the relativistic pairs are the targets for the protons to produce more pairs. This can produce X-ray fluxes with the characteristics observed in AGN. The model predicts the maximum ratio of luminosity to source size as well as their spectrum in the early phases. The same mechanism may also be able to create the knots of synchrotron-radiating pair plasma seen in sources such as 3C273.

  3. High brightness--multiple beamlets source for patterned X-ray production

    Science.gov (United States)

    Leung, Ka-Ngo [Hercules, CA; Ji, Qing [Albany, CA; Barletta, William A [Oakland, CA; Jiang, Ximan [El Cerrito, CA; Ji, Lili [Albany, CA

    2009-10-27

    Techniques for controllably directing beamlets to a target substrate are disclosed. The beamlets may be either positive ions or electrons. It has been shown that beamlets may be produced with a diameter of 1 .mu.m, with inter-aperture spacings of 12 .mu.m. An array of such beamlets, may be used for maskless lithography. By step-wise movement of the beamlets relative to the target substrate, individual devices may be directly e-beam written. Ion beams may be directly written as well. Due to the high brightness of the beamlets from extraction from a multicusp source, exposure times for lithographic exposure are thought to be minimized. Alternatively, the beamlets may be electrons striking a high Z material for X-ray production, thereafter collimated to provide patterned X-ray exposures such as those used in CAT scans. Such a device may be used for remote detection of explosives.

  4. A hard x-ray prototype production exposure station at NSLS

    International Nuclear Information System (INIS)

    Johnson, E.D.; Milne, J.C.

    1997-07-01

    Exposures conducted at the NSLS R and D beamline (X-27B) for High Aspect Ratio Precision Manufacture have proven sufficiently successful that the authors are constructing a dedicated hard x-ray exposure beamline. The new beamline (X-14B) provides an exposure field ∼ 120 mm wide, three times larger than that of X-27B. The scanner is based on the hydraulic system from the X-27B program. It is optimized for planar exposures and takes advantage of the full 525 mm stroke available. Exposures of multiple substrates and masks will be possible, with the fixturing supporting mounting of substrate holders from other groups (ALS, APS, CAMD, and UW). The function of this beamline is to establish a hard x-ray exposure station where manufacturing scale protocols can be developed and ultimately exploited for production runs

  5. Production of High Harmonic X-Ray Radiation from Non-linear Thomson at LLNL PLEIADES

    CERN Document Server

    Lim, Jae; Betts, Shawn; Crane, John; Doyuran, Adnan; Frigola, Pedro; Gibson, David J; Hartemann, Fred V; Rosenzweig, James E; Travish, Gil; Tremaine, Aaron M

    2005-01-01

    We describe an experiment for production of high harmonic x-ray radiation from Thomson backscattering of an ultra-short high power density laser by a relativistic electron beam at the PLEIADES facility at LLNL. In this scenario, electrons execute a “figure-8” motion under the influence of the high-intensity laser field, where the constant characterizing the field strength is expected to exceed unity: $aL=e*EL/m*c*ωL ≥ 1$. With large $aL$ this motion produces high harmonic x-ray radiation and significant broadening of the spectral peaks. This paper is intended to give a layout of the PLEIADES experiment, along with progress towards experimental goals.

  6. Electron beam production and characterization for the PLEIADES Thomson X-ray source

    International Nuclear Information System (INIS)

    Brown, W.J.; Hartemann, F.V.; Tremaine, A.M.; Springer, P.T.; Le Sage, G.P.; Barty, C.P.J.; Crane, J.K.; Cross, R.R.; Fittinghoff, D.N.; Slaughter, D.R.; Rosenzweig, J.B.; Anderson, S.; Gibson, D.J.

    2002-01-01

    We report on the performance of an S-band RF photocathode electron gun and accelerator for operation with the PLEIADES Thomson x-ray source at LLNL. Simulations of beam production, transport, and focus are presented. It is shown that a 1 ps, 500 pC electron bunch with a normalized emittance of less than 5 πmm-mrad can be delivered to the interaction point. Initial electron measurements are presented. Calculations of expected x-ray flux are also performed, demonstrating an expected peak spectral brightness of 1020 photons/s/mm2/mrad2/0.1% bandwidth. Effects of RF phase jitter are also presented, and planned phase measurements and control methods are discussed

  7. A strategy for vitrification product assurance and control with X-ray fluorescence spectrometry (PACX)

    International Nuclear Information System (INIS)

    Resce, J.L.

    1995-01-01

    A product control strategy is proposed for the vitrification of low-level and/or mixed waste. This strategy is called Product Assurance and Control with X-ray fluorescence spectrometry (PACX). The strategy utilizes sequential wavelength dispersive x-ray fluorescence spectrometry and standardless fundamental parameters calculations to analyze both the melter feed and the glassy products. The melter feed is sampled prior to addition to the melt tank and then melted and cast into samples which should closely resemble the product from the vitrification process itself. The resulting sample disks are then analyzed by x-ray fluorescence spectrometry. All elements with atomic numbers down to sodium can be determined directly and then either boron or lithium can be determined by difference from the mass balance. The XRF intensities are converted into oxide compositions with the use of a novel standardless fundamental parameters program. Previous work has shown that there is an excellent correlation between the XRF results and the results from conventional wet chemical analyses, but the XRF results can be obtained within two to three hours of sampling. If compositional control limits for durability are available, the product acceptability can be determined prior to the batch being introduced into the melter. The durability could also be estimated from a model, if available, which predicts product durability from composition. If the predicted durability is estimated to be too low, the model can then be used to determine additives which will raise the durability of the final product to within acceptable limits. The additives can then be incorporated into the batch prior to addition into the melter. A similar XRF analysis can be carried out on the glass product from the melter which can then be used to predict and thus assure product acceptance

  8. Measurements of absolute M-subshell X-ray production cross sections of Th by electron impact

    Energy Technology Data Exchange (ETDEWEB)

    Moy, A., E-mail: aurelien.moy@cea.fr [GM, CNRS, Université de Montpellier II, Place E. Bataillon, F-34095 Montpellier (France); CEA, DEN, DTEC, SGCS, LMAC, F-30207 Bagnols-sur-Cèze (France); Merlet, C. [GM, CNRS, Université de Montpellier II, Place E. Bataillon, F-34095 Montpellier (France); Dugne, O. [CEA, DEN, DTEC, SGCS, LMAC, F-30207 Bagnols-sur-Cèze (France)

    2014-08-31

    Highlights: • The M X-ray production cross sections of Th were measured by electron impact. • The M-subshell ionization cross sections of Th were determined from 3 to 38 keV. • Theoretical ionization cross-sections are in agreement with our experimental results. - Abstract: Measurements of absolute M-subshell X-ray production cross sections for element Th were made by electron impact for energies ranging from the ionization threshold up to 38 keV. Experimental data were obtained by measuring the X-ray intensity emitted from ultrathin Th films deposited onto self-supporting C backing films. The measurements were conducted with an electron microprobe using high-resolution wavelength dispersive spectrometers. Recorded intensities were converted into absolute X-ray production cross sections by means of atomic data and estimation of the number of primary electrons, target thickness, and detector efficiency. Our experimental X-ray production cross sections, the first to be reported for the M subshells of Th, are compared with X-ray production cross sections calculated with the mean of ionization cross sections obtained from the distorted-wave Born approximation. The Mα X-ray production cross section calculated is in excellent agreement with the measurements, allowing future use for standardless quantification in electron probe microanalysis.

  9. X-ray diffraction study of slags forming during corrosion resistant steel production

    International Nuclear Information System (INIS)

    Slavov, V.I.; Zadorozhnaya, V.N.; Shurygina, A.V.

    1990-01-01

    Using X-ray diffraction analysis slags, forming during corrosion-resistant 12Kh18N10T grade steel production by two flowsheets, are studied. Standard two-slag technology of steel production does not provide efficient disintegration of chromospinelides in slags, gives high steel contamination with respect to nonmetallic impurities, coarse structure and, as a consequence, presence of macrodefects on rolled products surface. One-slag steel melting technology with titanium alloying of the steel at vacuum causes fast removal of chromospinelides at the beginning of reduction period, promotes titanium absorption by the steel, refines nonmetallic inclusions, provides more fine structure and steel plasticity, removes surface defects

  10. Visual detection of particulates in x-ray images of processed meat products

    Science.gov (United States)

    Schatzki, Thomas F.; Young, Richard; Haff, Ron P.; Eye, J.; Wright, G.

    1996-08-01

    A study was conducted to test the efficacy of detecting particulate contaminants in processed meat samples by visual observation of line-scanned x-ray images. Six hundred field- collected processed-product samples were scanned at 230 cm2/s using 0.5 X 0.5-mm resolution and 50 kV, 13 mA excitation. The x-ray images were image corrected, digitally stored, and inspected off-line, using interactive image enhancement. Forty percent of the samples were spiked with added contaminants to establish the visual recognition of contaminants as a function of sample thickness (1 to 10 cm), texture of the x-ray image (smooth/textured), spike composition (wood/bone/glass), size (0.1 to 0.4 cm), and shape (splinter/round). The results were analyzed using a maximum likelihood logistic regression method. In packages less than 6 cm thick, 0.2-cm-thick bone chips were easily recognized, 0.1-cm glass splinters were recognized with some difficulty, while 0.4-cm-thick wood was generally missed. Operational feasibility in a time-constrained setting was confirmed. One half percent of the samples arriving from the field contained bone slivers > 1 cm long, 1/2% contained metallic material, while 4% contained particulates exceeding 0.3 cm in size. All of the latter appeared to be bone fragments.

  11. Production of hollow atoms by high brightness x-ray sources and its applications

    International Nuclear Information System (INIS)

    Moribayashi, Kengo

    2004-01-01

    We study x-ray emissions from the (multi-)inner-shell states and hollow atoms of Si ions excited by high intensity x-ray sources. It is found that the x-ray number from multi-inner-shell excited states (1s 2 2s 2 2p k 3s 2 3p 2 , k=1-4) and hollow atoms (1s 2 2s 2 3p 2 ) is affected greatly by the high intensity short-pulse x-rays and little by weak intensity post-long pulse x-rays. The ratio of the x-ray intensities from hollow atoms to those from the multi-inner-shell excited states becomes almost independent of the pulses and dependent on the intensities of x-ray sources. This ratio may be used for the measurement of intensities of high intensity short pulse x-ray sources. (author)

  12. Mobility-lifetime product in epitaxial GaAs X-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sun, G.C. [GESEC R and D, Universite Pierre et Marie Curie, Bat.11, 140 rue de Lourmel, 75015 Paris (France)]. E-mail: guocsun@ccr.jussieu.fr; Zazoui, M. [LPMC, Faculte des Sciences et Techniques-Mohammedia, B.P. 146 Bd Hassan II, Mohammedia, Maroc (Morocco); Talbi, N. [Faculte des Sciences, Universite de Gabes, Route de Medenine, 6029 Gabes (Tunisia); Khirouni, K. [Faculte des Sciences, Universite de Gabes, Route de Medenine, 6029 Gabes (Tunisia); Bourgoin, J.C. [GESEC R and D, Universite Pierre et Marie Curie, Bat.11, 140 rue de Lourmel, 75015 Paris (France)

    2007-04-01

    Self-supported thick (200-500 {mu}m), non-intentionally doped, epitaxial GaAs layers are good candidates for X-ray imaging for the following reasons. Their electronic properties are homogeneous over large areas, they can be grown at low cost, the technology to realize pixel detectors of various size is standard, the defect concentration is low and the fluorescence yield is small. Here, we characterize the defects present in the material and evaluate the mobility-lifetime product, using Deep Level Transient Spectroscopy combined with current-voltage and charge collection measurements.

  13. Transport equation theory of electron backscattering and x-ray production

    International Nuclear Information System (INIS)

    Fathers, D.J.; Rez, P.

    1978-02-01

    A transport equation theory of electron backscattering and x ray production is derived and applied to energy dissipation of 30-KeV electrons for copper as a function of depth and to the energy distribution of backscattered electrons for copper, aluminum, and gold. These results are plotted and compared with experiment. Plots for variations of backscattering with atomic number and with angle of incidence, and polar plots of backscattering for 30-keV electrons at normal incidence are also presented. 10 references, seven figures

  14. Quantifying movements of corrosion products in reinforced concrete using x-ray attenuation measurements

    DEFF Research Database (Denmark)

    Pease, Bradley Justin; Michel, Alexander; Stang, Henrik

    2011-01-01

    Corrosion of steel reinforcement, embedded in concrete, may substantially degrade concrete structures due to the expansive nature of corrosion products. Expansion of corrosion products cause tensile stresses to develop and cracks to form in concrete. Extensive research has focused on corrosion...... of corrosion products move into the concrete without generating tensile stresses and cracks in the concrete. Typically, corrosion products are thought to occupy pores, interfacial defects, and/or air voids located near the concrete-steel interface and stresses develop only after filling of these pores. Further....... X-ray attenuation measurements are also capable of detecting cracks. Therefore, this approach provides a direct measurement of the amount and location of reinforcement corrosion products required to induce cracking. Results of a parametric investigation on the impact of water-to-cement ratio (0...

  15. Radiological protection problems associated with parasitic X-ray emission from electronic products

    International Nuclear Information System (INIS)

    Amlinger, G.; Anger, K.; Billaudelle, H.; Ehlers, J.; Fendt, H.W.; Festag, J.G.; Haug, R.; Herrmann, K.H.; Klein, H.; Kossel, F.; Krebs, A.; Lauterbach, U.; Leibssle, H. Fa.; Lustig, H.; Maushart, R.; Milde, K.G.; Peter, F.; Ritter, J.; Riecke, W.D.; Rosenbaum, O.; Schiekel, M. Fa.; Schleich, F.; Schmidt, Th.; Speyer, K.; Teschke, L.; Tzschaschel, R.; Wagner, H.; Wehner, G.; Wendel, W.; Zehender, E.; Aiginoer, H.; Zakovsky, J.; Blom, G.; De backer, J.; Delhove, J.; Hublet, P.; Lejeune, P.; Misslin, A.; Nuyts, R.; Popovitch, I.; Hjardemaal, O.; Oehlenschlaeger, N.; Gonzalez Del Campo, R.; Becker, S.; Elder, R.L.; Matthews, J.D.; Sheldon, J.L.; Viitaniemi, T.J.; Aouizerate, H.; Aymeric, H.; Barthe, J.; Bermann, F.; Berthaud, Madeleine; Blanc, D.; Bory, P.; Bourrieau, J.; Bouville, A.; Bovagne, H.; Bresson, G.; Casanovas, J.; Cassanhiol, E.; Cassanhiol, E.; Chambragne, J.; Chanteur, J.; Choquet, R.; Cluchet, J.; Commanay, L.; Commanay, P.; Cros, J.L.; Dana, M.; Danna, J.; Decossas, J.L.; Delpla, M.; Destame, D.; Dieval, M.; Drouet, J.; Dubec, A.; Galy, J.; Garnier, A.; Gouerne, R.; Gras, M.; Grob, R.; Guelfucci, J.P.; Guevenoux, J.; Guichardiere, R.; Hamard, J.; Hardy, J.; Haym, J.P.; Hionette, J.; Jacob, G.; Lavie, J.M.; Levy, L.; Logre, P.; Manquene, J.; Martin, H.; Mathieu, J.; Odievre, Monique; Oustrin, J.; Palluel, P.; Patau, J.P.; Penotet, H.; Perrot, A.; Petel, M.; Peyrelavigne, A.; Peyrelavigne, Monique; Provincial, M.; Raedersdorff, J.; Renard, Cl.; Roche, L.; Roche, R.; Schaeffer, R.; Soubiran, J.; Soudain, G.; Stern, J.C.; Terrissol, M.; Tixier, M.; Vialettes, H.; Wauquier, J.M.; Casbolt, P.N.; Ciuciura, A.; Goodhew, E.G.; Jones, I.S.; O'riordan, M.C.; Speight, D.L.; Ward, P.R.; Williams, K.F.; Biro, T.; Vago, G.; Rosental, N.; Argiero, L.; Belli, M.; Boggio, M.; Carfi, N.; Garretti, S.; Loppa, A.; Parisi, A.; Susanna, A.; Ogawa, I.; Koren, K.; Aten, J.B.Th.; Barendsen, G.W.; Den Boer, A.M.; De Pijper, M.A.; Hekman, H.; Julius, H.W.; Strackee, L.; Van daatselaar, G.; Lorentzon, L.; Hadzi-Pealo, M.; Jeremio, M.; Stevanovio, Marija; Oosterkamp, W.J.; Shalmon, E.; Doyen, Diana; Goetschalkx, J.; Puel, R.

    1971-03-01

    During the past few decades there has been an increase in the production of many types of electronic devices such as rectifying tubes, thyratrons, klystrons, magnetrons, etc., containing elements capable of emitting undesirable X-radiation. These components are not only found in equipment used in industry and research laboratories, but also in devices of a more domestic nature, such as colour television sets, usually low in energy, this radiation may nevertheless constitute a health hazard for many users of such devices and may affect not only workers but even the population as a whole. The Commission of the European Communities (Euratom) felt it was desirable to review the state of the art with regard to problems of radiological protection arising in the manufacture, repair and use of such electronic equipment and to seek suitable technical and administrative solutions. In conjunction with the Centre Physique Atomique et Nucleaire of the Paul Sabatier University, the Commission held an International Symposium in Toulouse on 3-6 November 1970, which was attended by manufacturers of electronic equipment, officials of technical inspection bodies and representatives of public health and occupational safety authorities. The following items were discussed: classification and identification of sources of parasitic X-rays, methods of measuring soft X-rays, biological aspects of exposure to soft X-rays, performance standards and methods for testing and inspecting electronic equipment. The Symposium was followed attentively by 180 delegates from 21 countries and international organizations, and was concluded by a round table discussion at which the chairmen of the different sessions, assisted by experts, drew conclusions from their sessions and from the discussions, pointing up the problems which needed most urgently to be studied. This document contains the texts, in their original versions, of the papers presented at the meetings, together with the minutes of the

  16. Production and X-ray crystallographic analysis of fully deuterated human carbonic anhydrase II

    Energy Technology Data Exchange (ETDEWEB)

    Budayova-Spano, Monika [European Molecular Biology Laboratory Grenoble Outstation, 6 Rue Jules Horowitz, 38042 Grenoble (France); Institut Laue-Langevin, 6 Rue Jules Horowitz, BP 156, 38042 Grenoble (France); Fisher, S. Zoë [Department of Biochemistry and Molecular Biology, PO Box 100245, University of Florida, Gainesville, FL 32610 (United States); Dauvergne, Marie-Thérèse [European Molecular Biology Laboratory Grenoble Outstation, 6 Rue Jules Horowitz, 38042 Grenoble (France); Agbandje-McKenna, Mavis [Department of Biochemistry and Molecular Biology, PO Box 100245, University of Florida, Gainesville, FL 32610 (United States); Silverman, David N. [Department of Pharmacology and Therapeutics, PO Box 100267, University of Florida, Gainesville, FL 32610 (United States); Myles, Dean A. A. [European Molecular Biology Laboratory Grenoble Outstation, 6 Rue Jules Horowitz, 38042 Grenoble (France); Oak Ridge National Laboratory, PO Box 2008, Oak Ridge, TN 37831 (United States); McKenna, Robert, E-mail: rmckenna@ufl.edu [Department of Biochemistry and Molecular Biology, PO Box 100245, University of Florida, Gainesville, FL 32610 (United States); European Molecular Biology Laboratory Grenoble Outstation, 6 Rue Jules Horowitz, 38042 Grenoble (France)

    2006-01-01

    This article reports the production, crystallization and X-ray structure determination of perdeuterated human carbonic anhydrase (HCA II). The refined structure is shown to be highly isomorphous with hydrogenated HCA II, especially with regard to the active site architecture and solvent network. Human carbonic anhydrase II (HCA II) is a zinc metalloenzyme that catalyzes the reversible hydration and dehydration of carbon dioxide and bicarbonate, respectively. The rate-limiting step in catalysis is the intramolecular transfer of a proton between the zinc-bound solvent (H{sub 2}O/OH{sup −}) and the proton-shuttling residue His64. This distance (∼7.5 Å) is spanned by a well defined active-site solvent network stabilized by amino-acid side chains (Tyr7, Asn62, Asn67, Thr199 and Thr200). Despite the availability of high-resolution (∼1.0 Å) X-ray crystal structures of HCA II, there is currently no definitive information available on the positions and orientations of the H atoms of the solvent network or active-site amino acids and their ionization states. In preparation for neutron diffraction studies to elucidate this hydrogen-bonding network, perdeuterated HCA II has been expressed, purified, crystallized and its X-ray structure determined to 1.5 Å resolution. The refined structure is highly isomorphous with hydrogenated HCA II, especially with regard to the active-site architecture and solvent network. This work demonstrates the suitability of these crystals for neutron macromolecular crystallography.

  17. New X-ray testing methods of aerosol products for industrial radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bozydar Knyziak, Adrian, E-mail: a.knyziak@gum.gov.pl; Rzodkiewicz, Witold, E-mail: w.rzodkiewicz@gum.gov.pl; Kaczorowska, Ewa, E-mail: e.kaczorowska@gum.gov.pl; Derlacinski, Michal, E-mail: m.derlacinski@gum.gov.pl

    2017-02-01

    An amount of product in e.g. an aerosol canister is not difficult to estimate by weighing a filled can and subtracting the tare of packaging. In this way, we can obtain the net weight of the ingredients present in the can. Although, this does not indicate the volumetric content. Therefore, in the paper, the fundamental (the weight method and given by FEICA) and new methods (given by authors) related to the determination of the volumetric content of canister filled with aeorosol products are presented. The new methods are based on direct digital radiography (DR) using X-ray radiation. For the needs of new methods, the X-ray CCD-DR imaging system was built and developed in our Laboratory in Department of Radiation and Vibration at the Central Office of Measures. For comparison purposes, with regard to the volumetric content, a lot of metal cans of capacities 140, 185, 450, 700 ml were inspected. In future, computed tomography (CT) for industrial radiography in our laboratory will be used. Currently, an algorithm for CT is being tested. It will give us possibility for very precise measurements to determine volumetric content of examined canisters.

  18. Light ion induced L X-ray production cross-sections in Au and Pb

    International Nuclear Information System (INIS)

    Ouziane, S.; Amokrane, A.; Toumert, I.

    2008-01-01

    Experimental proton-induced L α , L β , L γ , L l and L tot absolute X-ray production cross-sections for Au and Pb in the incident proton energy range between 1 and 2.5 MeV are presented. The experimental results for X-ray production cross-sections are compared to available data given in Sokhi and Crumpton [R.S. Sokhi, D. Crumpton, At. Data Nucl. Data Tables 30 (1984) 49], Jesus et al. [A.P. Jesus, J.S. Lopes, J.P. Ribeiro, J. Phys. B: At. Mol. Phys. 18 (1985) 2456; A.P. Jesus, T.M. Pinheiro, I.A. Nisa, J.P. Ribeiro, J.S. Lopes, Nucl. Instrum. Methods B15 (1986) 95] and Goudarzi et al. [M. Goudarzi, F. Shokouhi, M. Lamehi-Rachti, P.Olialiy, Nucl. Instrum. Methods Phys. Res. B247 (2006) 218]. The given data are also compared with the predictions of ECPSSR model [W. Brandt, G. Lapicki, Phys. Rev. A23 (1981) 1717

  19. Radiation processing of food products with 5 MV Bremsstrahlung x-rays

    International Nuclear Information System (INIS)

    Petwal, V.C.; Soni, H.C.

    2004-01-01

    Foods and agricultural products are treated with ionizing radiation to accomplish many different goals. The desired goals may be the reduction of pathogenic bacteria, other microorganisms and parasites that cause food borne diseases; or inactivation of food spoilage organisms, including bacteria, molds, and yeasts; or lengthening the shelf-life of fresh fruits and vegetables by decreasing the normal biological changes associated with growth and maturation processes, such as ripening or sprouting. It has become more important due to mounting concern over food born diseases, and growing international trade in food products that must meet stiff import standards of quality and quarantine. A 10 MeV 10 kW LINAC based multi-product EB radiation processing facility is being established at CAT to meet the processing requirement of various food, agricultural and medical products. The facility will be operated in two modes: (a) Electron: 10 MeV, 10 kW (b) Photon: 5 MeV, 10 kW Treatment with electron beam provides the highest processing rate and lowest unit cost. But the electrons have relatively short range in the solid product, hence the maximum product areal density (density times depth) that can be processed using direct 10 MeV electron beam is limited to about 8.5 gm/cm 2 (double sided irradiation). On the other hand x-rays are more penetrating, hence can be used to process the products having larger areal densities e.g. onions and potatoes packed in gunny bags. In order to address various issues related to food irradiation using 5 MV X-ray beam, a mathematical model is developed on the basis of the analytical calculations and experimental data presented by R.B.Miller, 2003, and J. Meissner et.al, 2000. (author)

  20. Trial production of x-ray protective coat in clinico-orthodontics and evaluation of efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Fukui, H; Nezu, F; Arita, M; Numata, K; Nishioka, T [Nihon Univ., Tokyo. School of Dentistry

    1977-09-01

    The authors produced for trial an x-ray protective coat for patients which could be used for any type of dental roentogenography particularly by clinicoorthodontists and could easily exert a sufficient protective effect. The trial product is of coat type covering the front, sides, and back of the trunk and is made of vinyl sheet containing lead and rubber sheet containing lead. When patients put on the coat during cephalography, the internally absorbed dose was decreased greatly in the back corresponding to the 7th cervical vertebra and the area of thyroid and considerably in the area of right joint and the area corresponding to the center of the sternal shaft. The protective effect of the coat was also great in ortho-pantomography in regions corresponding to hemopoietic tissues abundant in bone-marrow, such as the areas of bilateral joints the back corresponding to the 7th cervical vertebra, and the area corresponding to the center of sternal shaft. Internally absorbed doses in different regions due to various types of roentgenography were tabulated. The x-ray protective coat was described to be useful not only in orthodontics but also in roentogenography in the craniocervical region.

  1. Visual detection of particulates in processed meat products by x ray

    Science.gov (United States)

    Schatzki, Thomas F.; Young, Richard; Haff, Ron P.; Eye, J.; Wright, G.

    1995-01-01

    A test has been run to study the efficacy of detecting particulate contaminants in processed meat samples by manual observation of line-scanned x-ray images. Six hundred processed product samples arriving over a 3 month period at a national USDA-FSIS laboratory were scanned at 230 cm2sec with 0.5 X 0.5 mm resolution, using 50 KV, 13 ma excitation, with digital interfacing and image correction. Images were inspected off-line, using interactive image enhancement. Forty percent of the samples were spiked, blind to the analyst, in order to establish the manual recognition rate as a function of sample thickness [1 - 10 cm] and texture of the x-ray image [smooth/textured], as well as spike composition [wood/bone/glass], size [1 - 4 mm] and shape [splinter/round]. The results have been analyzed using maximum likelihood logistic regression. In meat packages less than 6 cm thick, 2 mm bone chips are easily recognized, 1 mm glass splinters with some difficulty, while wood is generally missed even at 4 mm. Operational feasibility in a time-constrained setting has bee confirmed. One half percent of the samples arriving from the field contained bone slivers > 1 cm long, one half percent contained metallic material, while 4% contained particulates exceeding 3.2 mm in size. All of the latter appeared to be bone fragments.

  2. Trial production of x-ray protective coat in clinico-orthodontics and evaluation of efficiency

    International Nuclear Information System (INIS)

    Fukui, Hatsuo; Nezu, Fumio; Arita, Masatoshi; Numata, Keisuke; Nishioka, Toshio

    1977-01-01

    The authors produced for trial an x-ray protective coat for patients which could be used for any type of dental roentogenography particularly by clinicoorthodontists and could easily exert a sufficient protective effect. The trial product is of coat type covering the front, sides, and back of the trunk and is made of vinyl sheet containing lead and rubber sheet containing lead. When patients put on the coat during cephalography, the internally absorbed dose was decreased greatly in the back corresponding to the 7th cervical vertebra and the area of thyroid and considerably in the area of right joint and the area corresponding to the center of the sternal shaft. The protective effect of the coat was also great in ortho-pantomography in regions corresponding to hemopoietic tissues abundant in bone-marrow, such as the areas of bilateral joints the back corresponding to the 7th cervical vertebra, and the area corresponding to the center of sternal shaft. Internally absorbed doses in different regions due to various types of roentgenography were tabulated. The x-ray protective coat was described to be useful not only in orthodontics but also in roentogenography in the craniocervical region. (Chiba, N.)

  3. Next Generation Astronomical X-ray Optics: High Angular Resolution, Light Weight, and Low Production Cost

    Science.gov (United States)

    Zhang. W. W.; Biskach, M. P.; Blake, P. N.; Chan, K. W.; Gaskin, J. A.; Hong, M. L.; Jones, W. D.; Kolos, L. D.; Mazzarella, J. R.; McClelland, R. S.; hide

    2012-01-01

    X-ray astronomy depends on the availability of telescopes with high resolution and large photon collecting areas. Since x-ray observation can only be carried out above the atmosphere, these telescopes must be necessarily lightweight. Compounding the lightweight requirement is that an x-ray telescope consists of many nested concentric shells, which further require that x-ray mirrors must also be geometrically thin to achieve high packing efficiency. This double lightweight and geometrically thin requirement poses significant technical challenges in fabricating the mirrors and in integrating them into mirror assemblies. This paper reports on the approach, strategy and status of our x-ray optics development program whose objective is to meet these technical challenges at modest cost to enable future x-ray missions, including small Explorer missions in the near term, probe class missions in the medium term, and large flagship missions in the long term.

  4. An X-ray diffraction study of corrosion products from low carbon steel

    International Nuclear Information System (INIS)

    Morales, A. L.

    2003-01-01

    It was found in earlier work a decrease in the corrosion rate from low carbon steel when it was subjected to the action of a combined pollutant concentration (SO 4 ''2-=10''-4 M+Cl=1.5x 10''-3 M). It was also found that large magnetic content of the rust was related to higher corrosion rates. In the present study corrosion products are further analyzed by means of X-ray diffraction to account for composition changes during the corrosion process. it is found that lepidocrocite and goethite are the dominant components for the short-term corrosion in all batches considered while for log-term corrosion lepidocrite and goethite dominates if the corrosion rates is low and magnetite dominates if the corrosion rate is high. The mechanism for decreasing the corrosion rate is related to the inhibition of magnetite production at this particular concentration. (Author) 15 refs

  5. Photon-induced L X-ray production differential cross sections in thorium at 22.6 keV

    International Nuclear Information System (INIS)

    Puri, Sanjiv; Mehta, D.; Shahi, J.S.; Garg, M.L.; Singh, Nirmal; Trehan, P.N.

    1999-01-01

    The Ll, Lα, Lβ 2,4 , Lβ 1,3 and Lγ 1,5 X-ray production differential cross sections in 90 Th have been measured at 22.6 keV incident photon energy in an angular range 50-130 deg. The measurements were performed using a 109 Cd annular-source and a Si(Li) detector. The measured differential cross sections for various L X-rays are found to be angle-independent within experimental error. This is contrary to the strong angular-dependence of photon-induced Ll and Lα X-ray production cross sections as reported by Kahlon et al. (K.S. Kahlon, H.S. Aulakh, N. Singh, R. Mittal, K.L. Allawadhi, B.S. Sood, Phys. Rev. A 43 (1991) 1455) and Ertugrul (M. Ertugrul, Nucl. Instr. and Meth. B 119 (1996) 345). Integral cross sections for production of Ll, Lα, Lη, Lβ 6 , Lβ 2,4 , Lβ 1,3 , Lβ 9,10 , Lγ 1,5 and total Lγ X-rays are also deduced and are found to be in good agreement with those calculated using reliable theoretical values of the L i (i=1, 2, 3) subshell photoionisation cross sections, fluorescence yields, X-ray emission rates and Coster-Kronig transition probabilities

  6. Soft X-ray production by photon scattering in pulsating binary neutron star sources

    International Nuclear Information System (INIS)

    Bussard, R.W.; Meszaros, P.; Alexander, S.

    1985-01-01

    A new mechanism is proposed as a source of soft (less than 1 keV) radiation in binary pulsating X-ray sources, in the form of photon scattering which leaves the electron in an excited Landau level. In a plasma with parameters typical of such sources, the low-energy X-ray emissivity of this mechanism far exceeds that of bremsstrahlung. This copious source of soft photons is quite adequate to provide the seed photons needed to explain the power-law hard X-ray spectrum by inverse Comptonization on the hot electrons at the base of the accretion column. 13 references

  7. Lα and Mαβ X-ray production cross-sections of Bi by 6-30 keV electron impact

    Science.gov (United States)

    Liang, Y.; Xu, M. X.; Yuan, Y.; Wu, Y.; Qian, Z. C.; Chang, C. H.; Mei, C. S.; Zhu, J. J.; Moharram, K.

    2017-12-01

    In this paper, the Lα and Mαβ X-ray production cross-sections for Bi impacted by 6-30 keV electron have been measured. The experiments were performed at a Scanning Electron Microscope equipped with a silicon drift detector. The thin film with thick C substrate and the thin film deposited on self-supporting thin C film were both used as the targets to make a comparison. For the thick carbon substrate target, the Monte Carlo method has been used to eliminate the contribution of backscattering particles. The measured data are compared with the DWBA theoretical model and the experimental results in the literature. The experimental data for the thin film with thick C substrate target and the thin film deposited on self-supporting thin C film target are within reasonable gaps. The DWBA theoretical model gives good fit to the experimental data both for L- and M- shells. Besides, we also analyze the reasons why the discrepancies exist between our measurements and the experimental results in the literature.

  8. Sterilization of health care products by 5 MeV bremsstrahlung (X ray)

    International Nuclear Information System (INIS)

    Sato, Yoshishige; Takahashi, Thoru; Saito, Toshio; Sato, Toshio; Takehisa, Masaaki

    1993-01-01

    Radiation sensitivities of B. pumilis and B. subtilis spores were examined to bremsstrahlung of 5 MeV EB and Cobalt-60 γ rays in order to confirm the effects of radiation and dose rate. Biological indicators were irradiated with the X rays in the dose rate range of 4.7-47 kGy/h. D-value of B. pumilis spores was 1.4-1.5 kGy, and that of B. subtilis was 1.1-1.3 kGy. The D-values of B. pumilus and B. subtilis have very small dose rate dependences to X ray, and the D-values are similar to those of γ rays. Dose distribution by X-ray and γ irradiation was measured for cartons containing 32 unit dialyzers. The D max. /D min. of the X-ray irradiation (1.2) was smaller than that of γ ray (1.3). (author)

  9. A cell for extended x-ray absorption fine structure studies of oxygen sensitive products of redox reactions

    International Nuclear Information System (INIS)

    Furenlid, L.R.; Renner, M.W.; Fajer, J.

    1990-01-01

    We describe a cell suitable for extended x-ray absorption fine structure (EXAFS) studies of oxygen and/or water sensitive products of redox reactions. The cell utilizes aluminized Mylar windows that are transparent to x rays, provide low gas permeability, and allow vacuum to be maintained in the cell. The windows are attached to the glassware with an epoxy that resists attack by common organic solvents. Additional side arms allow multiple spectroscopic probes of the same sample under anaerobic and anhydrous conditions

  10. X-rays diffraction characterization of corrosion products transported by secondary side of a CANDU NPP

    International Nuclear Information System (INIS)

    Dinu, A.; Tunaru, M.; Velciu, L.

    2016-01-01

    To verify the chemistry of secondary side of CANDU steam generators, Millipore filters are used to sampling from condensing extraction pump, from feed water header and blow down of steam generator. These filters retain the corrosion products as very fine particles and are used as samples in chemistry water control. X-Ray diffraction technique is the able to distinguish the different crystallographic compounds present in oxide films deposited on the Millipore filters and gives information referring to the nature of corrosion products transported in secondary side. The XRD analysis has identified the following substance in deposited layer: magnetite (Fe_3O_4), hematite (Fe_2O_3), and iron oxide hydroxide (FeOOH). By optical microscopy it was observed a brown-reddish background specific to hematite and iron oxide hydroxide, especially for filters extracted from condensing extraction pump. The black colour of crud present on filters extracted from feed water header and blow down of steam generator shows the presence of magnetite. (authors)

  11. 3-D IMAGING, ANALYSIS AND MODELLING OF POROUS CEREAL PRODUCTS USING X-RAY MICROTOMOGRAPHY

    Directory of Open Access Journals (Sweden)

    Gerard Van Dalen

    2011-05-01

    Full Text Available Efficient design of multi-component food products containing dry and wet components such as biscuits with a moist fruit filling, is of growing interests for food industry. Technology is needed to prevent or reduce water migration from the moist filling to the dry porous cereal material. This can be done by using moisture barrier systems. Knowledge of the microstructure and its relation to water mobility is necessary to develop stable products. This paper describes a study that uses X-ray microtomography (μCT for the characterisation and visualisation of the 3-D structure of crackers with different porosity, coated biscuit shells and soup inclusions. μCT was used for imaging the inner cellular structure of the cereal matrix or to analyse the integrity of moisture barriers applied on the cereal product. 3-D image analysis methods were developed to obtain quantitative information about the cellular matrix which can be used as input for simulation models for moisture migration. The developed 3-D image analysis method maps the open cellular structure onto a network (graph representation in which the nodes correspond to the pores and the vertices to the pore-topore interconnection. The pores (nodes have properties such as volume, surface area and location whereas the vertices have properties such as direct (open connection and indirect (separated by a single lamella area. To check the segmentation and network description a model for pore to pore resistance was used. The obtained results demonstrate the potential of μCT and 3-D image analysis for extracting structural information which can be used in models for the moisture penetration in a cellular bakery product.

  12. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  13. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  14. Characteristic K-shell x-ray production by protons below 500 keV

    International Nuclear Information System (INIS)

    Wheeler, R.M.; Chaturvedi, R.P.; Zander, A.R.

    1974-01-01

    The total thick target yield of K-shell x-rays produced in Ni by incident protons over the energy range 90 to 415 keV was measured. Similar measurements with 130 to 415 keV protons were made for Ti, Mn, Fe, Cu, and Zn. The East Texas State University 150 keV Cockcroft--Walton accelerator was used to study Ni K-shell x-rays produced by 90 to 150 keV protons. The remaining data were taken with the SUNY College at Cortland 400 keV Van de Graaff generator. The characteristic x-rays were measured with high resolution Si(Li) detectors. Using the most recent values of K-shell fluorescent yields, x-ray ionization cross sections were calculated and compared to theoretical predictions based on the binary encounter approximation (BEA) model. It was found that even though the data were lower than those expected by the BEA theory, they lie on a universal curve. A comprehensive summary of x-ray ionization cross section references covering the proton energy range up to 500 keV is also included. Possible applications of low energy accelerators (E/sub p/ less than or equal to 500 keV) for further experimental work is discussed

  15. X-ray crystallographic studies on novel natural products from marine animals

    International Nuclear Information System (INIS)

    Choudhary, M.I.; Clardy, J.C.

    1991-01-01

    This chapter starts with an analysis to illustrate the utility of X-ray diffraction. The X-ray diffraction experiment is particularly suitable for structure elucidation of naturally occurring compounds, especially those that are structurally novel or have a great deal of stereochemistry. Marine plants and animals constitute a prodigious source of new and structurally complex secondary metabolites. Their unique structural features also provide strong incentives for further structural, synthetic and biosynthetic investigations. Organic compounds isolated from various marine animals in relatively small quantities, where structural work by conventional spectroscopic techniques did not lead to ambiguous structures, are investigated and the structures were finally determined through single-crystal X-ray diffraction measurements. (A.S.) 20 refs.; 5 figs

  16. Spectral dependence of point defect production by x rays in RbBr

    International Nuclear Information System (INIS)

    Brown, F.C.; Heald, S.M.; Jiang, D.; Brewe, D.L.; Kim, K.H.; Stern, E.A.

    1999-01-01

    F-center formation by monochromatic x rays has been studied above and below the bromine and rubidium K-absorption edges in crystals of RbBr. The x-ray beam from a double silicon crystal monochromator on an undulator at the Advanced Photon Source was used to produce these point defects, which were detected by a sensitive laser-induced luminescence method. Experiments were carried out over a wide range of monochromatic x-ray intensity, with emphasis on the nearly linear initial slope of defect formation with exposure. No significant increase in F-center formation efficiency was found upon crossing the bromine K edge, which indicates that additional Auger-cascade mechanisms do not appreciably add to the usual multiple ionization electron-hole recombination processes known to generate point defects. copyright 1999 The American Physical Society

  17. Maximization of bremsstrahlung and K-series production efficiencies in flash x-ray tubes

    International Nuclear Information System (INIS)

    Krehl, P.

    1986-01-01

    Historically, x-ray output of flash x-ray tubes was maximized empirically by changing the electrode geometry and varying the capacitance of the pulse generator. With the advent of high-voltage, low-impedance transmission lines, short-duration, high-current pulses could be generated with ease. An appropriate line scaling should assure that dose maximization is not reached at the expense of pulse prolongation which would reduce stop motion capability, but rather that dose rate should be maximized. Additionally, anode evaporation in the arc phase should be minimized to enhance tube life

  18. Short Pulse High Brightness X-ray Production with the PLEIADES Thomson Scattering Source

    International Nuclear Information System (INIS)

    Anderson, S.G.; Barty, C.P.J.; Betts, S.M.; Brown, W.J.; Crane, J.K.; Cross, R.R.; Fittinghoff, D.N.; Gibson, D.J.; Hartemann, F.V.; Kuba, J.; LaSage, G.P.; Rosenzweig, J.B.; Slaughter, D.R.; Springer, P.T.; Tremaine, A.M.

    2003-01-01

    We describe PLEIADES, a compact, tunable, high-brightness, ultra-short pulse, Thomson x-ray source. The peak brightness of the source is expected to exceed 10 20 photons/s/0.1% bandwidth/mm 2 /mrad 2 . Initial results are reported and compared to theoretical calculations

  19. Measurement of X-ray for the dose area product and spectrum by the added filtration in Rando phantom

    Science.gov (United States)

    Lee, Jong-Woong; Kim, Eun-Soo; Choi, Jiwon; Kweon, Dae Cheol

    2014-02-01

    The most important point in the medical use of radiation is to minimize the patient entrance dose while maintaining the diagnostic information. Low-energy photons (long-wave X-ray) are unnecessary among diagnostic X-ray because they are mostly absorbed and increase the patient's entrance dose. The most effective method to eliminate the low-energy photon is use of a filtering plate. Using a filter appropriate for the image will maintain diagnostic value. Obtaining an effective image allows comparison of the resulting images in a logical objective way. This experiment was performed to determine the quality of image dosimeter when there is no filter, and when 2 mm Al, 0.1 mm Cu + 1 mm Al, 0.2 mm Cu + 1 mm Al filters are used. Using TORECK PD-8100 dose area products meter placed on top of an abdominal phantom, we measured the dose when the filter changes in this condition 85 kVp, 40 mAs, anode angle 13, source image distance 100 cm, 20 cm × 20 cm. We used the SRS-78 program for accurate comparison because we could not evaluate the difference in the image optically. The spectrum changed due to the emission of X-rays as the filter changed. We observed that the use of a filter eliminated the low-energy photons and revealed continuous X-ray and special X-ray. Therefore, the experiment highlighted the advantages of filters and confirmed that there are no changes in the quality of image through signal to noise ratio, peak signal to noise ratio, root mean square error comparison. We found that the use of filter did not lead to distortions in the image or drop in diagnostic value while minimizing the radiation dose. This means that it can help manage long-term patient dose. We conclude that we need to recommend the use of the filter as it reduces the area of dose.

  20. X-ray sources

    International Nuclear Information System (INIS)

    Bonse, U.

    1979-11-01

    The author describes several possibilities for the production of X-radiation. Especially he discusses the use of bremsstrahlung at electron impact on solid targets and the synchrotron radiation. He presents some equations for the calculation of X-ray intensities. Especially the X-radiation from the DORIS storage ring is discussed. (HSI)

  1. Calibration of X-ray densitometers for the determination of uranium and plutonium concentrations in reprocessing input and product solutions

    International Nuclear Information System (INIS)

    Ottmar, H.; Eberle, H.; Michel-Piper, I.; Kuhn, E.; Johnson, E.

    1985-11-01

    In June 1985 a calibration exercise has been carried out, which included the calibration of the KfK K-Edge Densitometer for uranium assay in the uranium product solutions from reprocessing, and the calibration of the Hybrid K-Edge/K-XRF Instrument for the determination of total uranium and plutonium in reprocessing input solutions. The calibration measuremnts performed with the two X-ray densitometers are described and analyzed, and calibration constants are evaluated from the obtained results. (orig.)

  2. Tomographic X-ray apparatus for the production of transverse layer images

    International Nuclear Information System (INIS)

    Liebetruth, R.

    1984-01-01

    In an extension of the utility of rotary scan tomographic x-ray apparatus, the apparatus is locked in a fixed angular relationship and the patient support is automatically advanced in small longitudinal increments relative to the angularly fixed scanner, the scanner being pulsed in synchronism with the longitudinal steps to produce successive sets of transmittance readings defining a radiographic shadow image having a substantial longitudinal extent. The stored sets of readings may be reproduced on a conventional television display unit. Advantageously, the scanner may present a fan-type beam which in a fixed angular relationship to the patient still scans a substantial portion of the patient cross section, the x-ray source or sources being pulsed at successive longitudinal positions of the patient relative to the scanning apparatus, and the successive sets of readings being utilized for on line display of a shadow radiograph covering the desired longitudinal extent

  3. Hard X-ray bremsstrahlung production in solar flares by high-energy proton beams

    Science.gov (United States)

    Emslie, A. G.; Brown, J. C.

    1985-01-01

    The possibility that solar hard X-ray bremsstrahlung is produced by acceleration of stationary electrons by fast-moving protons, rather than vice versa, as commonly assumed, was investigated. It was found that a beam of protons which involves 1836 times fewer particles, each having an energy 1836 times greater than that of the electrons in the equivalent electron beam model, has exactly the same bremsstrahlung yield for a given target, i.e., the mechanism has an energetic efficiency equal to that of conventional bremsstrahlung models. Allowance for the different degrees of target ionization appropriate to the two models (for conventional flare geometries) makes the proton beam model more efficient than the electron beam model, by a factor of order three. The model places less stringent constraints than a conventional electron beam model on the flare energy release mechanism. It is also consistent with observed X-ray burst spectra, intensities, and directivities. The altitude distribution of hard X-rays predicted by the model agrees with observations only if nonvertical injection of the protons is assumed. The model is inconsistent with gamma-ray data in terms of conventional modeling.

  4. Screening of foods and related products for toxic elements with a portable X-ray tube analyzer

    International Nuclear Information System (INIS)

    Anderson, D.L.

    2009-01-01

    Capabilities of a portable X-ray tube-based analyzer were evaluated for screening foods, thin films, and ceramic glazes for toxic elements. A beverage spiked with Cr, Cu, and As and cocoa powder spiked with As and Pb could easily be distinguished from unadulterated products when analyzed through their original container walls. With calibration, results for thin films and ceramic glazes yielded accurate Pb results. Limits of detection (LODs) were 0.2-15 and 15 μg cm -2 , respectively, for Pb and Cd in thin films and about 2 μg cm -2 for Pb in glazes. With analysis times of 0.5-1 min, sensitivities and LODs were superior to those obtained with radioisotopic X-ray fluorescence analysis. (author)

  5. Production of High Harmonic X-ray Radiation from Non-linear Thomson Scattering at LLNL PLEIADES

    International Nuclear Information System (INIS)

    Lim, J; Doyuran, A; Frigola, P; Travish, G; Rosenzweig, J; Anderson, S; Betts, S; Crane, J; Gibson, D; Hartemann, F; Tremaine, A

    2005-01-01

    We describe an experiment for production of high harmonic x-ray radiation from Thomson backscattering of an ultra-short high power density laser by a relativistic electron beam at the PLEIADES facility at LLNL. In this scenario, electrons execute a ''figure-8'' motion under the influence of the high-intensity laser field, where the constant characterizing the field strength is expected to exceed unity: a L = eE L /m e cw L (ge) 1. With large a L this motion produces high harmonic x-ray radiation and significant broadening of the spectral peaks. This paper is intended to give a layout of the PLEIADES experiment, along with progress towards experimental goals

  6. Traditional x-ray imaging

    International Nuclear Information System (INIS)

    Hay, G.A.

    1982-01-01

    Methods of imaging x-rays, with particular reference to medicine, are reviewed. The history and nature of x-rays, their production and spectra, contrast, shapes and fine structure, image transducers, including fluorescent screens, radiography, fluoroscopy, and image intensifiers, image detection, perception and enhancement and clinical applications are considered. (U.K.)

  7. X-Ray

    Science.gov (United States)

    ... enema. What you can expect During the X-ray X-rays are performed at doctors' offices, dentists' offices, ... as those using a contrast medium. Your child's X-ray Restraints or other techniques may be used to ...

  8. Abdominal x-ray

    Science.gov (United States)

    Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  9. Chest X-Ray

    Medline Plus

    Full Text Available ... talk with you about chest radiography also known as chest x-rays. Chest x-rays are the ... treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray ...

  10. Initial Assessment of Electron and X-Ray Production and Charge Exchange in the NDCX-II Accelerator

    International Nuclear Information System (INIS)

    Cohen, R.H.

    2010-01-01

    The purpose of this note is to provide initial assessments of some atomic physics effects for the accelerator section of NDCX-II. There are several effects we address: the production of electrons associated with loss of beam ions to the walls, the production of electrons associated with ionization of background gas, the possibly resultant production of X-rays when these electrons hit bounding surfaces, and charge exchange of beam ions on background gas. The results presented here are based on a number of caveats that will be stated below, which we will attempt to remove in the near future.

  11. Interspecific comparisons of the sensitivity to chromosome aberration production by x rays

    International Nuclear Information System (INIS)

    Brewen, J.G.

    1978-01-01

    It is concluded that arm number probably plays a minor role, if any, in the relative radiosensitivity of a species. Instead the reported differences are probably a reflection of inherent basic biological mechanisms of repair that vary from one order of mammals to the next. It should be added, however, that the ultimate goal of all of these studies is to make a reasonable risk estimate for man. In that context the best approach is that of conservatism and the current data on mouse and man suggest that man has 1.5 to 2.0 times the risk of mice for chromosome rearrangement induction by x rays

  12. Focusing of megaampere electron beam in gas cell for production of flash X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Zinchenko, Vl; Chlenov, A M; Shiyan, V D [Research Institute of Scientific Instruments, Turaevo-Lytkarino (Russian Federation)

    1997-12-31

    One of important problems to be solved in the development of an intense source of flash X-rays is the choice of the optimum design of the high-current diode at the exit of the electron accelerator. The results of numerical investigations of megaampere relativistic electron beam (REB) generation and focusing in a compound diode are discussed. The diode consists of a vacuum field-emission annular cathode, a planar anode, and a gas cell inserted between the anode foil and the target. (author). 2 figs., 5 refs.

  13. Analysis of zirconia and alumina products and raw materials by X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Boix, A.; Draignaud, M.; Debras-Guedon, J.

    1975-01-01

    An X-ray fluorescence spectrometric method of analysis for various raw materials and materials based on zirconia, alumina and silica was developed. The measurements were made on beads made from the sample and a borax based flux, in the proportions 1:10. A repeatability test allowed the relative standard deviation to be estimated for the three main constituents: SiO 2 , Al 2 O 3 , ZrO 2 : it is at the level of 1%. The element analyzed are: Si, Al, Fe, Ti, Ca, Hf and Zr [fr

  14. Ultra-short period X-ray mirrors: Production and investigation

    International Nuclear Information System (INIS)

    Bibishkin, M.S.; Chkhalo, N.I.; Fraerman, A.A.; Pestov, A.E.; Prokhorov, K.A.; Salashchenko, N.N.; Vainer, Yu.A.

    2005-01-01

    Technological problems that deal with manufacturing of highly effective ultra-short (d=0.7-3.2 nm) period X-ray multilayer mirrors (MLM) are discussed in the article. In an example of Cr/Sc and W/B 4 C MLM it is experimentally shown, that the problem of periodicity and selectivity for multilayer dispersive X-ray elements has been generally solved by now. However, the problem of short-period MLM reflectivity increase related to existing of transitive borders between layers in structures remains rather urgent. The new technique of tungsten deposition using the RF source in order to decrease roughness in borders is discussed and tested. The results of measurements on wavelengths of 0.154, 0.834 and 1.759 nm are given. The RbAP crystals ordinary used in experiments and short-period W/B 4 C MLM produced are compared. The specular and non-specular characteristics of scattering on the 0.154 nm wavelengths are also measured in order to study transitive borders structures

  15. Use of X-ray and gamma-induced mutants of lactic acid bacteria in the manufacture of dairy products

    Energy Technology Data Exchange (ETDEWEB)

    Dilanian, Z; Makarian, K; Chuprina, D [Erevan Zootechnical and Veterinary Inst. (USSR). Chair of Dairying

    1976-04-01

    With the aid of X-ray and gamma irradiation were got mutants of lactic acid bacteria, which steadily retain acquired properties. Use of proteolytically active mutant strains in the production of armianski and sovetski cheeses shortened the time of their ripening and increased their quality. Gamma-mutant strain L. lactis 1621/I-M with high phenolstability was received and antibiotic activity with respect to some representatives of pathogenic microflora of the bowels. Use of this mutant in starters for sour milk products will raise their therapeutic effect against intestinal diseases. Deep morphological changes are taking place in lactic acid bacteria under the influence of ionizing radiation.

  16. Use of X-ray and gamma-induced mutants of lactic acid bacteria in the manufacture of dairy products

    International Nuclear Information System (INIS)

    Dilanian, Z.; Makarian, K.; Chuprina, D.

    1976-01-01

    With the aid of X-ray and gamma irradiation were got mutants of lactic acid bacteria, which steadily retain acquired properties. Use of proteolytically active mutant strains in the production of armianski and sovetski cheeses shortened the time of their ripening and increased their quality. Gamma-mutant strain L. lactis 1621/I-M with high phenolstability was received and antibiotic activity with respect to some representatives of pathogenic microflora of the bowels. Use of this mutant in starters for sour milk products will raise their therapeutic effect against intestinal diseases. Deep morphological changes are taking place in lactic acid bacteria under the influence of ionizing radiation. (orig.) [de

  17. A real-time regional adaptive exposure method for saving dose-area product in x-ray fluoroscopy

    International Nuclear Information System (INIS)

    Burion, Steve; Funk, Tobias; Speidel, Michael A.

    2013-01-01

    Purpose: Reduction of radiation dose in x-ray imaging has been recognized as a high priority in the medical community. Here the authors show that a regional adaptive exposure method can reduce dose-area product (DAP) in x-ray fluoroscopy. The authors' method is particularly geared toward providing dose savings for the pediatric population. Methods: The scanning beam digital x-ray system uses a large-area x-ray source with 8000 focal spots in combination with a small photon-counting detector. An imaging frame is obtained by acquiring and reconstructing up to 8000 detector images, each viewing only a small portion of the patient. Regional adaptive exposure was implemented by varying the exposure of the detector images depending on the local opacity of the object. A family of phantoms ranging in size from infant to obese adult was imaged in anteroposterior view with and without adaptive exposure. The DAP delivered to each phantom was measured in each case, and noise performance was compared by generating noise arrays to represent regional noise in the images. These noise arrays were generated by dividing the image into regions of about 6 mm 2 , calculating the relative noise in each region, and placing the relative noise value of each region in a one-dimensional array (noise array) sorted from highest to lowest. Dose-area product savings were calculated as the difference between the ratio of DAP with adaptive exposure to DAP without adaptive exposure. The authors modified this value by a correction factor that matches the noise arrays where relative noise is the highest to report a final dose-area product savings. Results: The average dose-area product saving across the phantom family was (42 ± 8)% with the highest dose-area product saving in the child-sized phantom (50%) and the lowest in the phantom mimicking an obese adult (23%). Conclusions: Phantom measurements indicate that a regional adaptive exposure method can produce large DAP savings without compromising

  18. Chest X-Ray

    Medline Plus

    Full Text Available ... about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed x-ray exams and use a very small dose of ... of the inside of the chest. A chest x-ray is used to evaluate the lungs, heart and ...

  19. Wire array Z-pinch insights for enhanced x-ray production

    Energy Technology Data Exchange (ETDEWEB)

    Sanford, T.W.; Mock, R.C.; Spielman, R.B. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1196 (United States); Haines, M.G.; Chittenden, J.P. [The Blackett Laboratory, Imperial College, London, SW7 2BZ (United Kingdom); Whitney, K.G.; Apruzese, J.P. [Naval Research Laboratory, Radiation Hydrodynamics Branch, Washington, D.C. 20375 (United States); Peterson, D.L. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Greenly, J.B.; Sinars, D.B. [Laboratory of Plasma Studies, Cornell University, Ithaca, New York 14853 (United States); Reisman, D.B. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Mosher, D. [Naval Research Laboratory, Pulsed Power Physics Branch, Washington, D.C. 20375 (United States)

    1999-05-01

    Comparisons of measured total radiated x-ray power from annular wire-array {ital z}-pinches with a variety of models as a function of wire number, array mass, and load radius are reviewed. The data, which are comprehensive, have provided important insights into the features of wire-array dynamics that are critical for high x-ray power generation. Collectively, the comparisons of the data with the model calculations suggest that a number of underlying dynamical mechanisms involving cylindrical asymmetries and plasma instabilities contribute to the measured characteristics. For example, under the general assumption that the measured risetime of the total-radiated-power pulse is related to the thickness of the plasma shell formed on axis, the Heuristic Model [IEEE Trans. Plasma Sci. {bold 26}, 1275 (1998)] agrees with the measured risetime under a number of specific assumptions about the way the breakdown of the wires, the wire-plasma expansion, and the Rayleigh{endash}Taylor instability in the r{endash}z plane, develop. Likewise, in the high wire-number regime (where the wires are calculated to form a plasma shell prior to significant radial motion of the shell) the comparisons show that the variation in the power of the radiation generated as a function of load mass and array radius can be simulated by the two-dimensional Eulerian-radiation- magnetohydrodynamics code (E-RMHC) [Phys. Plasmas {bold 3}, 368 (1996)], using a single random-density perturbation that seeds the Rayleigh{endash}Taylor instability in the r{endash}z plane. For a given pulse-power generator, the comparisons suggest that (1) the smallest interwire gaps compatible with practical load construction and (2) the minimum implosion time consistent with the optimum required energy coupling of the generator to the load should produce the highest total-radiated-power levels. {copyright} {ital 1999 American Institute of Physics.}

  20. Wire array Z-pinch insights for enhanced x-ray production

    Science.gov (United States)

    Sanford, T. W. L.; Mock, R. C.; Spielman, R. B.; Haines, M. G.; Chittenden, J. P.; Whitney, K. G.; Apruzese, J. P.; Peterson, D. L.; Greenly, J. B.; Sinars, D. B.; Reisman, D. B.; Mosher, D.

    1999-05-01

    Comparisons of measured total radiated x-ray power from annular wire-array z-pinches with a variety of models as a function of wire number, array mass, and load radius are reviewed. The data, which are comprehensive, have provided important insights into the features of wire-array dynamics that are critical for high x-ray power generation. Collectively, the comparisons of the data with the model calculations suggest that a number of underlying dynamical mechanisms involving cylindrical asymmetries and plasma instabilities contribute to the measured characteristics. For example, under the general assumption that the measured risetime of the total-radiated-power pulse is related to the thickness of the plasma shell formed on axis, the Heuristic Model [IEEE Trans. Plasma Sci. 26, 1275 (1998)] agrees with the measured risetime under a number of specific assumptions about the way the breakdown of the wires, the wire-plasma expansion, and the Rayleigh-Taylor instability in the r-z plane, develop. Likewise, in the high wire-number regime (where the wires are calculated to form a plasma shell prior to significant radial motion of the shell) the comparisons show that the variation in the power of the radiation generated as a function of load mass and array radius can be simulated by the two-dimensional Eulerian-radiation- magnetohydrodynamics code (E-RMHC) [Phys. Plasmas 3, 368 (1996)], using a single random-density perturbation that seeds the Rayleigh-Taylor instability in the r-z plane. For a given pulse-power generator, the comparisons suggest that (1) the smallest interwire gaps compatible with practical load construction and (2) the minimum implosion time consistent with the optimum required energy coupling of the generator to the load should produce the highest total-radiated-power levels.

  1. Wire Array Z-Pinch Insights for Enhanced X-Ray Production

    Energy Technology Data Exchange (ETDEWEB)

    Apruzese, J.P.; Chittenden, J.P.; Greenly, J.B.; Haines, M.G.; Mock, R.C.; Mosher, D.; Peterson, D.L.; Reisman, D.B.; Sanford, T.W.L.; Sinars, D.B.; Spielman, R.B.; Whitnery, K.G.

    1999-01-04

    Comparisons of measured total radiated x-ray power from annular wire-array z-pinches with a variety of models as a function of wire number, array mass, and load radius are reviewed. The data, which are comprehensive, have provided important insights into the features of wire-array dynamics that are critical for high x-ray power generation. Collectively, the comparisons of the data with the model calculations suggest that a number of underlying dynamical mechanisms involving cylindrical asymmetries and plasma instabilities contribute to the measured characteristics. For example, under the general assumption that the measured risetime of the total-radiated-power pulse is related to the thickness of the plasma shell formed on axis, the Heuristic Model [IEEE Trans. Plasma Sci., 26, 1275 (1998)] agrees with the measured risetime under a number of specific assumptions about the way the breakdown of the wires, the wire-plasma expansion, and the Rayleigh-Taylor instability in the r-z plane, interact. Likewise, in the high wire-number regime (where the wires are calculated to form a plasma shell prior to significant radial motion of the shell) the comparisons show that the variation in the power of the radiation generated as a function of load mass and array radius can be simulated by the 2-D Eulerian-radiation-magnetohydrodynamics code (E-RMHC) [Phys. Plasmas 3, 368 (1996)], using a single random-density perturbation that seeds the Rayleigh-Taylor instability in the r-z plane. For a given pulse-power generator, the comparisons suggest that (1) the smallest interwire gaps compatible with practical load construction and (2) the minimum implosion time consistent with the optimum required energy coupling of the generator to the load should produce the highest total-radiated-power levels.

  2. Wire array Z-pinch insights for enhanced x-ray production

    International Nuclear Information System (INIS)

    Sanford, T.W.; Mock, R.C.; Spielman, R.B.; Haines, M.G.; Chittenden, J.P.; Whitney, K.G.; Apruzese, J.P.; Peterson, D.L.; Greenly, J.B.; Sinars, D.B.; Reisman, D.B.; Mosher, D.

    1999-01-01

    Comparisons of measured total radiated x-ray power from annular wire-array z-pinches with a variety of models as a function of wire number, array mass, and load radius are reviewed. The data, which are comprehensive, have provided important insights into the features of wire-array dynamics that are critical for high x-ray power generation. Collectively, the comparisons of the data with the model calculations suggest that a number of underlying dynamical mechanisms involving cylindrical asymmetries and plasma instabilities contribute to the measured characteristics. For example, under the general assumption that the measured risetime of the total-radiated-power pulse is related to the thickness of the plasma shell formed on axis, the Heuristic Model [IEEE Trans. Plasma Sci. 26, 1275 (1998)] agrees with the measured risetime under a number of specific assumptions about the way the breakdown of the wires, the wire-plasma expansion, and the Rayleigh - Taylor instability in the r - z plane, develop. Likewise, in the high wire-number regime (where the wires are calculated to form a plasma shell prior to significant radial motion of the shell) the comparisons show that the variation in the power of the radiation generated as a function of load mass and array radius can be simulated by the two-dimensional Eulerian-radiation- magnetohydrodynamics code (E-RMHC) [Phys. Plasmas 3, 368 (1996)], using a single random-density perturbation that seeds the Rayleigh - Taylor instability in the r - z plane. For a given pulse-power generator, the comparisons suggest that (1) the smallest interwire gaps compatible with practical load construction and (2) the minimum implosion time consistent with the optimum required energy coupling of the generator to the load should produce the highest total-radiated-power levels. copyright 1999 American Institute of Physics

  3. Hypersensitivity of Allium cepa seedling roots to X-rays for production of micronuclei

    International Nuclear Information System (INIS)

    Hori, Takayoshi; Hanmoto, Hidehiro; Fujishige, Ikuko; Inoue, Toshihiro; Taniguchi, Kenji; Itoh, Tetsuo; Fujikawa, Kazuo; Yonezawa, Yoshihiko.

    1995-01-01

    Seedling roots of onion (Allium cepa) were irradiated with various doses of X-rays. Following irradiation, the roots were incubated at 23-25degC for 24 hr, i.e., approximate time for one mitotic cycle, and then fixed, stained and macerated in a 7:3 mixture of acetic dahlia (prepared by dissolving a 0.5 g sample of dahlia violet into 100 ml of 30% acetate) and 1 N HCl for 10-15 min. Terminal 1-2 mm of the root tips were squashed on slides, one root each, and microscopically inspected for the presence of more than one nucleus in the cells. The additional nuclei, which were smaller than the normal, were scored as micronuclei. The frequency of micronuclei increased with dose over the control level (∼0.2x10 -3 ) to a high level of 140x10 -3 at 1 Gy. The frequency recorded at 1 Gy was about two fold higher as compared with the frequency reported by Evans et al. (1959) for micronuclei induced by γ-rays at a comparable dose in the root tip cells of Vica faba seedlings, probably reflecting relatively higher DNA content per cell in Allium somatic cells. We thus may conclude that root-tip meristematic cells of Allium seedlings are hypersensitive to the induction of micronuclei by X-rays. The Allium micronucleus assay may be useful as a system not only for quantitating chromosome damage by low-level radiation but also for detecting environmental mutagens. (author)

  4. Wire Array Z-Pinch Insights for Enhanced X-Ray Production

    International Nuclear Information System (INIS)

    Apruzese, J.P.; Chittenden, J.P.; Greenly, J.B.; Haines, M.G.; Mock, R.C.; Mosher, D.; Peterson, D.L.; Reisman, D.B.; Sanford, T.W.L.; Sinars, D.B.; Spielman, R.B.; Whitnery, K.G.

    1999-01-01

    Comparisons of measured total radiated x-ray power from annular wire-array z-pinches with a variety of models as a function of wire number, array mass, and load radius are reviewed. The data, which are comprehensive, have provided important insights into the features of wire-array dynamics that are critical for high x-ray power generation. Collectively, the comparisons of the data with the model calculations suggest that a number of underlying dynamical mechanisms involving cylindrical asymmetries and plasma instabilities contribute to the measured characteristics. For example, under the general assumption that the measured risetime of the total-radiated-power pulse is related to the thickness of the plasma shell formed on axis, the Heuristic Model [IEEE Trans. Plasma Sci., 26, 1275 (1998)] agrees with the measured risetime under a number of specific assumptions about the way the breakdown of the wires, the wire-plasma expansion, and the Rayleigh-Taylor instability in the r-z plane, interact. Likewise, in the high wire-number regime (where the wires are calculated to form a plasma shell prior to significant radial motion of the shell) the comparisons show that the variation in the power of the radiation generated as a function of load mass and array radius can be simulated by the 2-D Eulerian-radiation-magnetohydrodynamics code (E-RMHC) [Phys. Plasmas 3, 368 (1996)], using a single random-density perturbation that seeds the Rayleigh-Taylor instability in the r-z plane. For a given pulse-power generator, the comparisons suggest that (1) the smallest interwire gaps compatible with practical load construction and (2) the minimum implosion time consistent with the optimum required energy coupling of the generator to the load should produce the highest total-radiated-power levels

  5. X-ray sky

    International Nuclear Information System (INIS)

    Gruen, M.; Koubsky, P.

    1977-01-01

    The history is described of the discoveries of X-ray sources in the sky. The individual X-ray detectors are described in more detail, i.e., gas counters, scintillation detectors, semiconductor detectors, and the principles of X-ray spectrometry and of radiation collimation aimed at increased resolution are discussed. Currently, over 200 celestial X-ray sources are known. Some were identified as nebulae, in some pulsations were found or the source was identified as a binary star. X-ray bursts of novae were also observed. The X-ray radiation is briefly mentioned of spherical star clusters and of extragalactic X-ray sources. (Oy)

  6. Universal empirical fit to L-shell X-ray production cross sections in ionization by protons

    Science.gov (United States)

    Lapicki, G.; Miranda, J.

    2018-01-01

    A compilation published in 2014, with a recent 2017 update, contains 5730 experimental total L-shell X-ray production cross sections (XRPCS). The database covers an energy range from 10 keV to 1 GeV, and targets from 18Ar to 95Am. With only two adjustable parameters, universal fit to these data normalized to XRPCS calculated at proton velocity v1 equal to the electron velocity in the L-shell v2L, is obtained in terms of a single ratio of v1/v2L. This fit reproduces 97% of the compiled XRPCS to within a factor of 2.

  7. K-shell X-ray production cross sections of Ni induced by protons, alpha-particles, and He{sup +}

    Energy Technology Data Exchange (ETDEWEB)

    Bertol, A.P.L. [Programa de Pós-graduação em Física, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Hinrichs, R. [Programa de Pós-graduação em Física, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Instituto de Geociências, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Vasconcellos, M.A.Z., E-mail: marcos@if.ufrgs.br [Programa de Pós-graduação em Física, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Instituto de Física, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil)

    2015-11-15

    The proton, alpha-particle, and He{sup +} induced X-ray emissions of Ni were measured on mono-elemental thin films in order to obtain the K-shell X-ray production cross section in the energy range of 0.7–2.0 MeV for protons, 4.0–6.5 MeV for alpha-particles, and 3.0–4.0 MeV for He{sup +}. The proton-induced X-ray production cross section for Ni agreed well with the theoretical values, endorsing the quality of the measurements. The X-ray production cross section induced with alpha-particles is in good agreement with ECPSSR theory in the complete range of energies, while for He{sup +} that quantity is systematically below. K{sub β}/K{sub α} ratios were evaluated and compared with experimental and theoretical values.

  8. K X-ray production cross sections, Kβ/Kα ratios, and radiative Auger ratios for protons impacting low-Z elements

    International Nuclear Information System (INIS)

    Cipolla, Sam J.

    1999-01-01

    A Cockcroft-Walton accelerator was used to produce 50-300 keV protons to excite characteristic X-rays from thick targets of elements from Z=21 to 32, using an efficiency-calibrated Si(Li) detector equipped with an ultra-thin window. X-ray production cross sections were determined and compared with prevailing theories. Special attention was paid to accounting for the radiative Auger effects (RAE) in the analysis of the X-ray energy spectra. Ratios of RAE to K α and K β intensities, as well as K β /K α ratios, will be compared to theoretical values

  9. Nondestructive, energy-dispersive x-ray fluorescence analysis of product-stream concentrations from reprocessed LWR fuels

    International Nuclear Information System (INIS)

    Camp, D.C.; Ruhter, W.D.; Benjamin, S.

    1979-01-01

    Energy-dispersive x-ray fluorescence analysis can be used for quantitative on-line monitoring of the product concentrations in single- or dual-element process streams in a reprocessing plant. The 122-keV gamma ray from 57 Co is used to excite the K x-rays of uranium and/or plutonium in nitric acid solution streams. A collimated HPGe detector is used to measure the excited x-ray intensities. Net solution radioactivity may be measured by eclipsing the exciting radiation, or by measuring it simultaneously with a second detector. The technique is nondestructive and noninvasive, and is easily adapted directly to pipes containing the solution of interest. The dynamic range of the technique extends from below 1 to 500 g/l. Measurement times depend on concentration, but better than 1% counting statistics can be obtained in 100 s for 400 g/l concentrations, and in 1000 s for as little as 10 g/l. Calibration accuracies of 0.3% or better over the entire dynamic range can be achieved easily using carefully prepared standards. Computer-based analysis equipment allows concentration changes in flowing streams to be dynamically monitored. Changes in acid normality of the stream will affect the concentration determined, hence it must also be determined by measuring the intensity of a transmitted 57 Co beam. The computer/disk-based pulse-height analysis system allows all necessary calculations to be done on-line. Experimental requirements for an in-plant installation or a test and evaluation are discussed

  10. Application of X-ray digital radiography to online automated inspection of interior assembly structures of complex products

    International Nuclear Information System (INIS)

    Han Yueping; Han Yan; Li Ruihong; Wang Liming

    2009-01-01

    The paper proposes an application of X-ray digital radiography to online automated inspection and recognition of the interior assembly structures of complex products by means of the multiple views techniques. First, a vertical hybrid projection function (VHPF) is proposed as the recognition feature of a two-dimensional image. VHPF combines an integral projection function and a standard deviation function so that it can reflect the mean and the variance of the pixels in the vertical direction in an image. Secondly, by considering the different importance grades of objects inside the product and the independence of these objects along the circumference, the paper presents a hierarchical recognition method and uses a neural network system to speed up the computation process with parallel operations. Thirdly, using the whole-orientation features of one standard swatch and by extracting its maximal system of linear independence as the feature basis, the issue of blind areas for recognition is resolved. Based on this approach, the first domestic X-ray multi-view digital detection system has been developed and applied to the online detection of objects containing complicated assembly structures.

  11. Investigation of the radiation leakage from X ray flaw detectors and the improvement measures for the unqualified products

    International Nuclear Information System (INIS)

    Li Yiachun; Wu Yi; Pang Hu; Bai Bin

    1997-01-01

    The authors introduce investigation methods and results for radiation leakage from X ray flaw detectors, which are used in Beijing area. Total 21 sets of flaw detectors made in 8 factories in Beijing, Shanghai etc. have been tested, of which 16 sets made in Beijing, Dandong and Japan are gas cooling flaw detectors, and rest 5 sets made in Shanghai and Germany are water or oil cooling detectors. The air Kerma rate of leakage radiation at 1 m from the X ray tube target were measured by Type FJ-347A X, γ dosimeter. It can be seen from the results that, compared with the trade standard ZBY315-83, 5 sets of water or oil cooling flaw detectors are all qualified. However, only two sets of gas cooling detectors are qualified, and the radiation leakage of another 14 sets are over the values specified in the standard. The reason is analyzed, and some advices about the measures of improving radiation protection structure design and production technology for the unqualified products have been proposed

  12. X-Rays, Pregnancy and You

    Science.gov (United States)

    ... Emitting Products and Procedures Medical Imaging Medical X-ray Imaging X-Rays, Pregnancy and You Share Tweet Linkedin Pin it ... the decision with your doctor. What Kind of X-Rays Can Affect the Unborn Child? During most x- ...

  13. Production of muscovite-feldspathic glass composite: scanning electron microscopy and X-ray diffraction analysis

    International Nuclear Information System (INIS)

    Costa, F.P.F.; Ogasawara, T.; Santos, S.F.

    2009-01-01

    The objective of this work was to find the sintering conditions for the feldspathic glass + muscovite mixture to produce a dense composite block for manufacturing dental prosthesis by using CAD-CAM. Each 20g of the glass-frit had : 15.55g of Armil-feldspar; 0.53g of Al 2 O 3 ; 1.56g of Na 2 CO 3 ; 0.5g of borax; 1.74g of K 2 CO 3 ; 0.13g of CeO 2 . Frit's powder finer than 350 Tyler mesh was mixed with 0 wt%, 10 wt%, 20 wt% and 100 wt% of muscovite pressed cylinders (5600 pounds force) 16mm in diameter and sintered under vacuum Vacumat (VITA) furnace at 850 deg C, 900 deg C, 950 deg C, 1000 deg C, 1050 deg C, 1100 deg C and 1150 deg C. X-ray diffraction analysis and scanning electron microscopy were carried out. The necessary temperature for high densification depended on the composition of the mixture: 850 deg C (for pure frit); 1050 deg C (for 10 wt% mica) and 1150 deg C (for 20 wt% mica); pure mica degraded during sintering. (author)

  14. Laser System for Photoelectron and X-Ray Production in the PLEIADES Compton Light Source

    CERN Document Server

    Gibson, David J; Betts, S; Crane, John; Jovanovic, Igor

    2005-01-01

    The PLEIADES (Picosecond Laser-Electron Interaction for the Dynamic Evaluation of Structures) facility provides tunable short x-ray pulses with energies of 30-140 keV and pulse durations of 0.3 - 5 ps by scattering an intense, ultrashort laser pulse off a 35-75 MeV electron beam. Synchronization of the laser and electron beam is obtained by using a photoinjector gun, and using the same laser system to generate the electrons and the scattering laser. The Ti:Sapphire, chirped pulse amplification based 500 mJ, 50 fs, 810 nm scattering laser and the similar 300 μJ, 5 ps, 266 nm photoinjector laser systems are detailed. Additionally, an optical parametric chirped pulse amplification (OPCPA) system is studied as a replacement for part of the scattering laser front end. Such a change would significantly simplify the set-up the laser system by removing the need for active switching optics, as well as increase the pre-pulse contrast ratio which will be important when part of the scattering laser is used as a...

  15. Production, crystallization and preliminary X-ray diffraction analysis of the allergen Can f 2 from Canis familiaris

    International Nuclear Information System (INIS)

    Madhurantakam, Chaithanya; Nilsson, Ola B.; Jönsson, Klas; Grönlund, Hans; Achour, Adnane

    2009-01-01

    The recombinant form of the allergen Can f 2 from C. familiaris was produced, isolated and crystallized in two different forms. Preliminary X-ray diffraction analyses are reported for the two crystal forms of Can f 2. The allergen Can f 2 from dog (Canis familiaris) present in saliva, dander and fur is an important cause of allergic sensitization worldwide. Here, the production, isolation, crystallization and preliminary X-ray diffraction analysis of two crystal forms of recombinant Can f 2 are reported. The first crystal form belonged to space group C222, with unit-cell parameters a = 68.7, b = 77.3, c = 65.1 Å, and diffracted to 1.55 Å resolution, while the second crystal form belonged to space group C2, with unit-cell parameters a = 75.7, b = 48.3, c = 68.7 Å, β = 126.5°, and diffracted to 2.1 Å resolution. Preliminary data analysis indicated the presence of a single molecule in the asymmetric unit for both crystal forms

  16. On the mechanism of X-ray production by dart leaders of lightning flashes

    Science.gov (United States)

    Cooray, Vernon; Dwyer, Joseph; Rakov, V.; Rahman, Mahbubur

    2010-07-01

    Radiation with energies up to about 250 keV associated with the dart leader phase of rocket-triggered lightning were reported by Dwyer et al. (2004). The mechanism of X-ray generation by dart leaders, however, is unknown at present. Recently, Cooray et al. (2009a) developed physical concepts and mathematical techniques necessary to calculate the electric field associated with the tip of dart leaders. We have utilized the results of these calculations together with the energy dependent frictional force on electrons, as presented by Moss et al. (2006), to evaluate the maximum energy an electron will receive in accelerating in the dart-leader-tip electric field. The main assumptions made in performing the calculations are: (a) the dart leader channel is straight and vertical; (b) the path of the electrons are straight inside the channel; and (c) the decay of the channel temperature is uniform along the length of the dart leader. In the calculation, we have taken into account the fact that the electric field is changing both in space and time and that the gas in the defunct return stroke channel is at atmospheric pressure and at elevated temperature (i.e. reduced gas density). The results of the calculation show that for a given dart leader current there is a critical defunct-return-stroke-channel temperature above which the cold electron runaway becomes feasible. For a typical dart leader, this temperature is around 2500 K. This critical temperature decreases with increase in dart leader current. Since the temperature of the defunct return stroke channel may lie in the range of 2000-4000 K, the results show that the electric field at the tip of dart leaders is capable of accelerating electrons to MeV energy levels.

  17. Production of humoral factors that stimulate spleen colony-forming units in mice irradiated with moderate doses of X rays

    International Nuclear Information System (INIS)

    Grande, T.; Gonzalez, J.; Tejero, C.; Maganto, G.; Bueren, J.A.

    1990-01-01

    The production of humoral factors that stimulate spleen colony-forming units (CFU-S) has been studied in irradiated mice using an in vivo diffusion chamber assay. The experiments show that a significant release of factors that stimulate CFU-S takes place in the first few days after irradiation with moderate doses of 1.5 or 5 Gy. In contrast, the release of significant amounts of these humoral factors was not seen in animals irradiated with either low (0.75 Gy) or high (10 Gy) doses of X rays. The correlation observed between the production of factors that stimulate the CFU-S and the hemopoietic regeneration kinetics of the irradiated mice suggests that these factors represent part of the physiological regulators controlling the proliferation of CFU-S

  18. Chest X-Ray

    Medline Plus

    Full Text Available ... some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a ... posted: How to Obtain and Share ...

  19. Chest X-Ray

    Medline Plus

    Full Text Available ... X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey Rubin, a radiologist ... about chest x-rays, visit Radiology Info dot org. Thank you for your time! Spotlight Recently posted: ...

  20. X-ray apparatus

    International Nuclear Information System (INIS)

    Sell, L.J.

    1981-01-01

    A diagnostic x-ray device, readily convertible between conventional radiographic and tomographic operating modes, is described. An improved drive system interconnects and drives the x-ray source and the imaging device through coordinated movements for tomography

  1. X-ray - skeleton

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003381.htm X-ray - skeleton To use the sharing features on this ... Degenerative bone conditions Osteomyelitis Risks There is low radiation exposure. X-rays machines are set to provide the smallest ...

  2. X-ray screening materials

    International Nuclear Information System (INIS)

    Wardley, R.B.

    1981-01-01

    This invention relates to x-ray screening materials and especially to materials in sheet form for use in the production of, for example, protective clothing such as aprons and lower back shields, curtains, mobile screens and suspended shields. The invention is based on the observation that x-ray screening materials in sheet form having greater flexiblity than the hitherto known x-ray screening materials of the same x-ray absorber content can be produced if, instead of using a single sheet of filled sheet material of increased thickness, one uses a plurality of sheets of lesser thickness together forming a laminar material of the desired thickness and one bonds the individual sheets together at their edges and, optionally, at other spaced apart points away from the edges thereby allowing one sheet to move relative to another. (U.K.)

  3. Chest X-Ray

    Medline Plus

    Full Text Available ... I’d like to talk with you about chest radiography also known as chest x-rays. Chest x-rays are the most ... far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot org. Thank you for your time! ...

  4. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... you about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed ...

  5. X-rays as a probe of the Universe

    Indian Academy of Sciences (India)

    Table of contents. X-rays as a probe of the Universe · Probing the Universe ….. Flux = sT4 umax = 1011 T (in Kelvin) · History of x-ray astronomy · X-ray Production · X-ray spectra · Celestial sphere as seen by UHURU (1970) · Slide 8 · X-rays from accreting binary systems · Slide 10 · Neutron stars: Black Hole: · Primary X-ray ...

  6. Errata and update to ;Experimental cross sections for L-shell X-ray production and ionization by protons;

    Science.gov (United States)

    Miranda, J.; Lapicki, G.

    2018-01-01

    A compilation of experimental L-shell X-ray production and ionization cross sections induced by proton impact was published recently (Miranda and Lapicki, 2014), collecting 15 439 experimental cross sections. The database covers an energy range from 10 keV to 1 GeV, and targets from 10Ne to 95Am. A correction to several tabulated values that were in error, as well as an update including new data published after 2012 and older references not found previously are given in the present work. The updated data base increased the total number of experimental cross sections by 3.1% to 15 921. A new analysis of the total number of experimental points per year shows that the possible saturation in the cumulative total number of data is increased to 15 950 ± 110 points.

  7. X-ray-induced production of granulocyte-macrophage colony-stimulating factor (GM-CSF) by mouse spleen cells in culture

    International Nuclear Information System (INIS)

    Onoda, M.; Shinoda, M.; Tsuneoka, K.; Shikita, M.

    1980-01-01

    Spleen cells were collected from normal mice and cultured in a medium containing 20% calf serum. Addition of lipopolysaccharide (LPS) in the culture significantly increased the production of granulocyte-macrophage colony-stimulating factor (GM-CSF), and a maximum induction was attained in 5 days. Irradiation of the spleen cells with 300 to 3000 R x rays also enhanced the production of GM-CSF, but there was a latent period of about 5 days before the factor appeared in the culture medium. The observed difference between LPS and x rays in the timing of inducing GM-CSF production in the spleen cell culture was consistent with the difference observed in animals. These results suggest that different mechanisms of GM-CSF production operate in the spleen in response to either LPS or x rays

  8. Suresh K. AggarwalQuantified Analysis of a Production Diesel Injector Using X-Ray Radiography and Engine Diagnostics

    Science.gov (United States)

    Ramirez, Anita I.

    The work presented in this thesis pursues further the understanding of fuel spray, combustion, performance, and emissions in an internal combustion engine. Various experimental techniques including x-ray radiography, injection rate measurement, and in-cylinder endoscopy are employed in this work to characterize the effects of various upstream conditions such as injection rate profile and fuel physical properties. A single non-evaporating spray from a 6-hole full-production Hydraulically Actuated Electronically Controlled Unit Injector (HEUI) nozzle is studied under engine-like ambient densities with x-ray radiography at the Advanced Photon Source (APS) of Argonne National Laboratory (ANL). Two different injection pressures were investigated and parameters such as fuel mass distribution, spray penetration, cone angle, and spray velocity were obtained. The data acquired with x-ray radiography is used for the development and validation of improved Computational Fluid Dynamic (CFD) models. Rate of injection is studied using the same HEUI in a single cylinder Caterpillar test engine. The injection rate profile is altered to have three levels of initial injection pressure rise. Combustion behavior, engine performance, and emissions information was acquired for three rate profile variations. It is found that NOx emission reduction is achieved when the SOI timing is constant at the penalty of lower power generated in the cycle. However, if CA50 is aligned amongst the three profiles, the NOx emissions and power are constant with a slight penalty in CO emissions. The influence of physical and chemical parameters of fuel is examined in a study of the heavy alcohol, phytol (C20H40O), in internal combustion engine application. Phytol is blended with diesel in 5%, 10%, and 20% by volume. Combustion behavior is similar between pure diesel and the phytol/diesel blends with small differences noted in peak cylinder pressure, ignition delay, and heat release rate in the premix burn

  9. Mutation effects of kojic acid production strain induced by synchrotron radiation of soft X-rays and kinetics of the fermentation

    International Nuclear Information System (INIS)

    Chen Liang; Jiang Shiping; Wan Libiao; Ma Xiaodong; Li Meifang

    2006-01-01

    The irradiation effect on Aspergillus oryzae spores was studied by 0.54 keV X-rays (about the K shell absorption edge of oxygen) from the synchrotron facility at NSRL. A high production mutant for kojic acid was obtained from the spores irradiated by soft X-rays, which accumulated 27.79 g kojic acid per L in 500 mL shake-flask fermentation for 10 days using glucose as carbon source, and has increased about 56% of production than that of the original (17.81 g/L). Also the fermentation conditions were studied with different carbon sources and nitrogen sources. The results showed that the mutant induced by the X-rays of synchrotron radiation would be of potential for high kojic acid production. (authors)

  10. Quantitative determination on heavy metals in different stages of wine production by Total Reflection X-ray Fluorescence and Energy Dispersive X-ray Fluorescence: Comparison on two vineyards

    Energy Technology Data Exchange (ETDEWEB)

    Pessanha, Sofia [Centro Fisica Atomica, Departamento de Fisica, Faculdade de Ciencias, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa (Portugal); Carvalho, Maria Luisa, E-mail: luisa@cii.fc.ul.p [Centro Fisica Atomica, Departamento de Fisica, Faculdade de Ciencias, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa (Portugal); Becker, Maria; Bohlen, Alex von [Institute for analytical Sciences, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund (Germany)

    2010-06-15

    The purpose of this study is to determine the elemental content, namely heavy metals, of samples of vine-leaves, grapes must and wine. In order to assess the influence of the vineyard age on the elemental content throughout the several stages of wine production, elemental determinations of trace elements were made on products obtained from two vineyards aged 6 and 14 years from Douro region. The elemental content of vine-leaves and grapes was determined by Energy Dispersive X-Ray Fluorescence (EDXRF), while analysis of the must and wine was performed by Total Reflection X-ray Fluorescence (TXRF). Almost all elements present in wine and must samples did not exceed the recommended values found in literature for wine. Bromine was present in the 6 years old wine in a concentration 1 order of magnitude greater than what is usually detected. The Cu content in vine-leaves from the older vineyard was found to be extremely high probably due to excessive use of Cu-based fungicides to control vine downy mildew. Higher Cu content was also detected in grapes although not so pronounced. Concerning the wine a slightly higher level was detected on the older vineyard, even so not exceeding the recommended value.

  11. Quantitative determination on heavy metals in different stages of wine production by Total Reflection X-ray Fluorescence and Energy Dispersive X-ray Fluorescence: Comparison on two vineyards

    International Nuclear Information System (INIS)

    Pessanha, Sofia; Carvalho, Maria Luisa; Becker, Maria; Bohlen, Alex von

    2010-01-01

    The purpose of this study is to determine the elemental content, namely heavy metals, of samples of vine-leaves, grapes must and wine. In order to assess the influence of the vineyard age on the elemental content throughout the several stages of wine production, elemental determinations of trace elements were made on products obtained from two vineyards aged 6 and 14 years from Douro region. The elemental content of vine-leaves and grapes was determined by Energy Dispersive X-Ray Fluorescence (EDXRF), while analysis of the must and wine was performed by Total Reflection X-ray Fluorescence (TXRF). Almost all elements present in wine and must samples did not exceed the recommended values found in literature for wine. Bromine was present in the 6 years old wine in a concentration 1 order of magnitude greater than what is usually detected. The Cu content in vine-leaves from the older vineyard was found to be extremely high probably due to excessive use of Cu-based fungicides to control vine downy mildew. Higher Cu content was also detected in grapes although not so pronounced. Concerning the wine a slightly higher level was detected on the older vineyard, even so not exceeding the recommended value.

  12. X-ray astronomy

    International Nuclear Information System (INIS)

    Culhane, J.L.; Sanford, P.W.

    1981-01-01

    X-ray astronomy has been established as a powerful means of observing matter in its most extreme form. The energy liberated by sources discovered in our Galaxy has confirmed that collapsed stars of great density, and with intense gravitational fields, can be studied by making observations in the X-ray part of the electromagnetic spectrum. The astronomical objects which emit detectable X-rays include our own Sun and extend to quasars at the edge of the Universe. This book describes the history, techniques and results obtained in the first twenty-five years of exploration. Space rockets and satellites are essential for carrying the instruments above the Earth's atmosphere where it becomes possible to view the X-rays from stars and nebulae. The subject is covered in chapters, entitled: the birth of X-ray astronomy; the nature of X-radiation; X-rays from the Sun; solar-flare X-rays; X-rays from beyond the solar system; supernovae and their remnants; X-rays from binary stars; white dwarfs and neutron stars; black holes; X-rays from galaxies and quasars; clusters of galaxies; the observatories of the future. (author)

  13. Thermal analysis, X-ray powder diffraction and electron microscopy data related with the production of 1:1 Caffeine:Glutaric Acid cocrystals

    Directory of Open Access Journals (Sweden)

    Íris Duarte

    2016-09-01

    Full Text Available The data presented in this article are related to the production of 1:1 Caffeine:Glutaric Acid cocrystals as part of the research article entitled “Green production of cocrystals using a new solvent-free approach by spray congealing” (Duarte et al., 2016 [1]. More specifically, here we present the thermal analysis and the X-ray powder diffraction data for pure Glutaric Acid, used as a raw material in [1]. We also include the X-ray powder diffraction and electron microscopy data obtained for the 1:1 Caffeine:Glutaric Acid cocrystal (form II produced using the cooling crystallization method reported in “Operating Regions in Cooling Cocrystallization of Caffeine and Glutaric Acid in Acetonitrile” (Yu et al., 2010 [2]. Lastly, we show the X-ray powder diffraction data obtained for assessing the purity of the 1:1 Caffeine:Glutaric cocrystals produced in [1].

  14. The Presence of Thermally Unstable X-Ray Filaments and the Production of Cold Gas in the NGC 5044 Group

    Energy Technology Data Exchange (ETDEWEB)

    David, Laurence P.; Vrtilek, Jan; O’Sullivan, Ewan; Jones, Christine; Forman, William [Harvard-Smithsonian Center for Astrophysics, 60 Garden St., Cambridge, MA 02138 (United States); Sun, Ming, E-mail: ldavid@head.cfa.harvard.edu [Department of Physics, University of Alabama in Huntsville, Huntsville, AL 35899 (United States)

    2017-06-20

    We present the results of a deep Chandra observation of the X-ray bright moderate-cooling flow group NGC 5044 along with the observed correlations between the ionized, atomic, and molecular gas in this system. The Chandra observation shows that the central AGN has undergone two outbursts in the past 10{sup 8} years, based on the presence of two pairs of nearly bipolar X-ray cavities. The molecular gas and dust within the central 2 kpc is aligned with the orientation of the inner pair of bipolar X-ray cavities, suggesting that the most recent AGN outburst had a dynamical impact on the molecular gas. NGC 5044 also hosts many X-ray filaments within the central 8 kpc, but there are no obvious connections between the X-ray and H α filaments and the more extended X-ray cavities that were inflated during the prior AGN outburst. Using the line width of the blended Fe-L line complex as a diagnostic for multiphase gas, we find that the majority of the multiphase thermally unstable gas in NGC 5044 is confined within the X-ray filaments. While the cooling time and entropy of the gas within the X-ray filaments are very similar, not all filaments show evidence of gas cooling or an association with H α emission. We suggest that the various observed properties of the X-ray filaments are suggestive of an evolutionary sequence where thermally unstable gas begins to cool, becomes multiphased, develops H α emitting plasma, and finally produces cold gas.

  15. The application of photoconductive detectors to the measurement of x-ray production in laser produced plasmas

    International Nuclear Information System (INIS)

    Kania, D.R.; Bell, P.; Trebes, J.

    1987-08-01

    Photoconductive detectors (PCDs) offer an attractive alternative for the measurement of pulsed x-rays from laser produced plasmas. These devices are fast (FWHM ∼100 ps), sensitive and simple to use. We have used InP, GaAs, and Type IIa diamond as PCDs to measure x-rays emission from 100 eV to 100 keV. Specifically, we have used these detectors to measure total radiation yields, corona temperatures, and hot electron generated x-rays from laser produced plasmas. 5 refs., 4 figs

  16. Pair production instabilities as a source of X-ray flares from accreting black holes

    Energy Technology Data Exchange (ETDEWEB)

    Moskalik, P; Sikora, M

    1986-02-20

    The paper concerns pair production instability in active galaxies which emit most of their energy at h..gamma..>100 keV. The authors show that the esub(..gamma..)-e-pair production instability leads to cyclic variations of accretion flow, during which high-energy flares are produced. This mechanism can account for the large amplitude luminosity changes observed in several active galactic nuclei. The same scenario may also be responsible for the short-timescale quasiperiodic variability reported in some proposed galactic black holes. (U.K.).

  17. A FOURIER-TRANSFORMED BREMSSTRAHLUNG FLASH MODEL FOR THE PRODUCTION OF X-RAY TIME LAGS IN ACCRETING BLACK HOLE SOURCES

    International Nuclear Information System (INIS)

    Kroon, John J.; Becker, Peter A.

    2014-01-01

    Accreting black hole sources show a wide variety of rapid time variability, including the manifestation of time lags during X-ray transients, in which a delay (phase shift) is observed between the Fourier components of the hard and soft spectra. Despite a large body of observational evidence for time lags, no fundamental physical explanation for the origin of this phenomenon has been presented. We develop a new theoretical model for the production of X-ray time lags based on an exact analytical solution for the Fourier transform describing the diffusion and Comptonization of seed photons propagating through a spherical corona. The resulting Green's function can be convolved with any source distribution to compute the associated Fourier transform and time lags, hence allowing us to explore a wide variety of injection scenarios. We show that thermal Comptonization is able to self-consistently explain both the X-ray time lags and the steady-state (quiescent) X-ray spectrum observed in the low-hard state of Cyg X-1. The reprocessing of bremsstrahlung seed photons produces X-ray time lags that diminish with increasing Fourier frequency, in agreement with the observations for a wide range of sources

  18. X-ray holography

    International Nuclear Information System (INIS)

    Faigel, G.; Tegze, M.; Belakhovsky, M.; Marchesini, S.; Bortel, G.

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples

  19. Scanning electron microscopy and X-ray energy dispersive spectroscopy - useful tools in the analysis of pharmaceutical products

    Science.gov (United States)

    Sarecka-Hujar, Beata; Balwierz, Radoslaw; Ostrozka-Cieslik, Aneta; Dyja, Renata; Lukowiec, Dariusz; Jankowski, Andrzej

    2017-11-01

    The quality of the drug, its purity and identification of degradation products provide the highest quality of pharmaceutical products. The energy dispersive spectroscopy (EDS) method analyses the percentage of each element form as well as their distribution, and morphological characteristics of the drug form. We analysed the usefulness of EDS method in testing orally disintegrating tablets (ODT) with trimetazidine hydrochloride with high resolution scanning electron microscopy (SEM, SUPRA25 Carl Zeiss company) with spectrophotometer equipped with an X-ray energy dispersion (EDAX Company). The samples of the analysed tablets were imaged after applying conductive layers of gold on their surface. In the EDS analysis the compositions of each sample of the obtained tablets were observed to be virtually identical. The differences in the content of carbon and oxygen came from differences in the composition of particular tablets. The presence of gold in the composition resulted from the sputtering the surface of tablets with gold during the analysis. Knowing the composition of the tablet, SEM-EDS method helps to locate and identify the impurities and degradation products of the compounds, leading to a better understanding of the mechanisms of their formation.

  20. X-ray diffraction phase analysis of crystalline copper corrosion products after treatment in different chloride solutions

    International Nuclear Information System (INIS)

    Chmielova, M.; Seidlerova, J.; Weiss, Z.

    2003-01-01

    The corrosion products Cu 2 (OH) 3 Cl, Cu 2 O, and CuCl 2 were identified on the surface of copper plates after their four days treating in three different sodium chloride, sodium/magnesium, and sodium/calcium chloride solutions using X-ray diffraction powder analysis. However, the quantitative proportions of individual corrosion products differ and depend on the type of chloride solution used. Treating of copper plates only in the sodium chloride solution produced the mixture of corrosion products where Cu 2 O is prevailing over the Cu 2 (OH) 3 Cl and CuCl 2 was not identified. The sample developed after treating of the cooper surface in the sodium/magnesium chloride solution contains Cu 2 (OH) 3 Cl and CuCl 2 prevailing over the Cu 2 O, while the sample developed after treatment of copper in sodium/calcium chloride solution contains Cu 2 (OH) 3 Cl prevailing over CuCl 2 and Cu 2 O was not identified

  1. Providing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.

    1985-01-01

    This invention provides an apparatus for providing x-rays to an object that may be in an ordinary environment such as air at approximately atmospheric pressure. The apparatus comprises: means (typically a laser beam) for directing energy onto a target to produce x-rays of a selected spectrum and intensity at the target; a fluid-tight enclosure around the target; means for maintaining the pressure in the first enclosure substantially below atmospheric pressure; a fluid-tight second enclosure adjoining the first enclosure, the common wall portion having an opening large enough to permit x-rays to pass through but small enough to allow the pressure reducing means to evacuate gas from the first enclosure at least as fast as it enters through the opening; the second enclosure filled with a gas that is highly transparent to x-rays; the wall of the second enclosure to which the x-rays travel having a portion that is highly transparent to x-rays (usually a beryllium or plastic foil), so that the object to which the x-rays are to be provided may be located outside the second enclosure and adjacent thereto and thus receive the x-rays substantially unimpeded by air or other intervening matter. The apparatus is particularly suited to obtaining EXAFS (extended x-ray fine structure spectroscopy) data on a material

  2. L-shell X-ray production of molybdenum and niobium induced by 1500–3500 keV Xe26+ ions

    International Nuclear Information System (INIS)

    Guo, Yipan; Yang, Zhihu; Song, Zhangyong; Xu, Qiumei; Chen, Jing; Yang, Bian

    2013-01-01

    L-shell X-ray production cross sections are measured for molybdenum and niobium target induced by Xe 26+ ions. The incident energy range varies from 1500 to 3500 keV. The experimental results are well reproduced by the binding-energy-modified binary encounter approximation model in the united-atom limit. In addition to target L-shell X-ray spectra, we also observe a weak spectrum which corresponds to the forbidden transition 3d → 2s from the projectiles

  3. Laser-powered dielectric-structures for the production of high-brightness electron and x-ray beams

    Science.gov (United States)

    Travish, Gil; Yoder, Rodney B.

    2011-05-01

    Laser powered accelerators have been under intensive study for the past decade due to their promise of high gradients and leveraging of rapid technological progress in photonics. Of the various acceleration schemes under examination, those based on dielectric structures may enable the production of relativistic electron beams in breadbox sized systems. When combined with undulators having optical-wavelength periods, these systems could produce high brilliance x-rays which find application in, for instance, medical and industrial imaging. These beams also may open the way for table-top atto-second sciences. Development and testing of these dielectric structures faces a number of challenges including complex beam dynamics, new demands on lasers and optical coupling, beam injection schemes, and fabrication. We describe one approach being pursued at UCLA-the Micro Accelerator Platform (MAP). A structure similar to the MAP has also been designed which produces periodic deflections and acts as an undulator for radiation production, and the prospects for this device will be considered. The lessons learned from the multi-year effort to realize these devices will be presented. Challenges remain with acceleration of sub-relativistic beams, focusing, beam phase stability and extension of these devices to higher beam energies. Our progress in addressing these hurdles will be summarized. Finally, the demands on laser technology and optical coupling will be detailed.

  4. Kβ/ Kα intensity ratios for X-ray production in 3d metals by gamma-rays and protons

    Science.gov (United States)

    Bhuinya, C. R.; Padhi, H. C.

    1994-04-01

    Systematic measurements of Kβ/ Kα intensity ratios for X-ray production in 3d metals have been carried out using γ-ray and fast proton ionization methods. The measured ratios from proton ionization experiments indicate production of multivacancies in the L shell giving rise to higher Kβ/ Kα ratios compared to the present γRF results and 2 MeV proton ionization results of Perujo et al. [Perujo A., Maxwell J. A., Teesdale W. J. and Cambell J. L. (1987) J. Phys. B: Atom. Molec. Phys.20, 4973]. This is consistent with the SCA model calculation which gives increased simultaneous K- and L-shell ionization at 4 MeV. The present results from γRF experiments are in close agreement with the 2 MeV proton ionization results of Perujo et al. (1987) and also with the theoretical calculation of jankowski and Polasik [Jankowski K. and Polasik M. (1989) J. Phys. B: Atom. Molec. Optic. Phys. 22, 2369] but the theoretical results of Scofield [Scofield J. H. (1974a) Atom. Data Nucl. Data Tables14, 12] are somewhat higher.

  5. Crystallization and preliminary X-ray analysis of AbsC, a novel regulator of antibiotic production in Streptomyces coelicolor

    International Nuclear Information System (INIS)

    Stevenson, Clare E. M.; Kock, Holger; Mootien, Saraspadee; Davies, Sîan C.; Bibb, Mervyn J.; Lawson, David M.

    2007-01-01

    A novel regulator of antibiotic production in S. coelicolor, AbsC, has been crystallized in space group P2 1 2 1 2 1 . X-ray data to 2.25 Å resolution were collected on station PX 14.1 at Daresbury. Crystals of recombinant AbsC (subunit MW = 18 313 Da; 158 amino acids), a novel regulator of antibiotic production from Streptomyces coelicolor, were grown by vapour diffusion. The protein crystallizes in space group P2 1 2 1 2 1 , with unit-cell parameters a = 43.53, b = 121.30, c = 143.75 Å. Native data to a resolution of 2.25 Å were recorded at station PX 14.1 (Daresbury) from a single crystal. Preliminary analysis of these data suggests that the asymmetric unit contains four copies of the AbsC monomer, giving an estimated solvent content of 47.0%. AbsC belongs to the MarR family of proteins that mediate ligand-responsive transcriptional control

  6. Semiquantitative analysis of corrosion products in iron channel by the X-ray diffraction technique

    International Nuclear Information System (INIS)

    Bueno, C.R.E.; Varela, J.A.

    1995-01-01

    The corrosion in the us very important in the slag line region, but in others regions over and above this line there is a corrosion process still important. We have made a detailed mapping of phases present in seven different regions in the iron channel in three distinct positions. After the phases identifications, it was made a deconvolution of the diffractograms using Gaussian functions. The analysis of the relative intensity of each phase gave an idea for a semi-quantitative analysis and we have proposed a mechanism of the refractory corrosion. It was observed that the calcium oxide migrates by diffusion to different regions originating low melting point products like pseudo-wolastonite, anorthite and guelenite. (author)

  7. M-shell ionization of heavy elements by 0.1-1.0 MeV/amu 1,2H and 3,4He ions

    International Nuclear Information System (INIS)

    Pajek, M.; Banas, D.; Braziewicz, J.; Czarnota, M.; Bienkowski, A.; Jaskola, M.; Korman, A.; Trautmann, D.; Lapicki, G.

    2006-01-01

    The M-shell ionization in high-Z atoms by low-energy light 1 1 H, 1 2 H, 2 3 He, and 2 4 He ions have been studied systematically in the energy range 0.1-1.0 MeV/amu in order to verify the available theoretical approaches describing the M-shell ionization by charged particles in asymmetric collisions. The present low-energy data, combined with our earlier results reported for M-shell ionization by hydrogen and helium ions for higher energies, form a systematic experimental basis to test the theoretical predictions of M-shell ionization based on the plane-wave Born approximation (PWBA), the semiclassical approximation (SCA), and the binary-encounter approximation (BEA). In the PWBA based approaches the energy loss (E), Coulomb deflection (C), perturbed stationary state (PSS), and relativistic (R) effects were considered within the ECPSSR theory and its recent modification, called the ECUSAR theory, in which a description of the PSS effect was corrected to account for the united- and separated-atom (USA) electron binding energy limits. In the SCA calculations with relativistic wave functions the binding effect was included only in the limiting cases of separated-atom and united-atom limits. Possible contribution of the electron capture, multiple ionization, and recoil ionization to the M-shell vacancy production, which is dominated for light ions impact by direct single ionization process, are also discussed. The universal scaling of measured M-shell x-ray production and ionization cross sections was investigated in detail. Using the present data the isotopic effect has been studied by comparing the measured M-shell ionization cross-section ratios for equal-velocity hydrogen 1 1 H and 1 2 H as well as helium 2 3 He and 2 4 He isotopes. In addition, the ratios of measured ionization cross sections for 1 2 H and 2 4 He were used to investigate the role of the binding effect. The present results are of practical importance for the application of particle-induced x-ray

  8. X-ray interferometers

    International Nuclear Information System (INIS)

    Franks, A.

    1980-01-01

    An improved type of amplitude-division x-ray interferometer is described. The wavelength at which the interferometer can operate is variable, allowing the instrument to be used to measure x-ray wavelength, and the angle of inclination is variable for sample investigation. (U.K.)

  9. Extremity x-ray

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003461.htm Extremity x-ray To use the sharing features on this page, ... in the body Risks There is low-level radiation exposure. X-rays are monitored and regulated to provide the ...

  10. X-rays utilization

    International Nuclear Information System (INIS)

    Rebigan, F.

    1979-03-01

    The modality of X-ray utilization in different activities and economy is given. One presents firstly quantities and units used in radiation dosimetry and other fields. One gives the generation of X-rays, their properties as well as the elements of radiation protection. The utilization characteristics of these radiations in different fields are finally given. (author)

  11. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... d like to talk with you about chest radiography also known as chest x-rays. Chest x- ...

  12. X-ray induced DNA double strand break production and repair in mammalian cells as measured by neutral filter elution

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, M O; Kohn, K W [National Institutes of Health, Bethesda, MD (USA)

    1979-10-01

    A neutral filter elution method was used for detecting DNA double strand breaks in mouse L1210 cells after X-ray. The assay detected the number of double strand breaks induced by as little as 1000 rad of X-ray. The rate of DNA elution through the filters under neutral conditions increased with X-ray dose. Certain conditions for deproteinization, pH, and filter type were shown to increase the assay's sensitivity. Hydrogen peroxide and Bleomycin also induced apparent DNA double strand breaks, although the ratios of double to single strand breaks varied from those produced by X-ray. The introduction of double strand cuts by HpA I restriction endonuclease in DNA lysed on filters resulted in a rapid rate of elution under neutral conditions, implying that the method can detect double strand breaks if they exist in the DNA. The eluted DNA banded with a double stranded DNA marker in cesium chloride. This evidence suggested that the assay detected DNA double strand breaks. L1210 cells were shown to rejoin most of the DNA double strand breaks induced by 5-10 krad of X-ray with a half-time of about 40 minutes. (author).

  13. Handbook of X-Ray Data

    CERN Document Server

    Zschornack, Günter

    2007-01-01

    This sourcebook is intended as an X-ray data reference for scientists and engineers working in the field of energy or wavelength dispersive X-ray spectrometry and related fields of basic and applied research, technology, or process and quality controlling. In a concise and informative manner, the most important data connected with the emission of characteristic X-ray lines are tabulated for all elements up to Z = 95 (Americium). This includes X-ray energies, emission rates and widths as well as level characteristics such as binding energies, fluorescence yields, level widths and absorption edges. The tabulated data are characterized and, in most cases, evaluated. Furthermore, all important processes and phenomena connected with the production, emission and detection of characteristic X-rays are discussed. This reference book addresses all researchers and practitioners working with X-ray radiation and fills a gap in the available literature.

  14. Generation of relativistic electron bunches in plasma synchrotron Gyrac-x for hard x-ray production

    International Nuclear Information System (INIS)

    Andreev, V.V.; Umnov, A.M.

    2000-01-01

    Experiment performed on plasma synchrotron Gyrac-X operating on synchrotron gyromagnetic autoresonance (SGA) is described. Gyrac-X is a compact plasma x-ray source in which kinetic energy of relativistic electrons obtained under SGA converts into x-ray by falling e-bunches on to a heavy metal target. The plasma synchrotron acts in a regime of a magnetic field pulse packet under constant level of microwave power. Experiments and numerical modeling of the process showed that such a regime allowed obtaining dense short lived relativistic electron bunches with average electron energy of 500 keV - 4.5 MeV. Parameters of the relativistic electron bunch (energy, density and volume) and dynamics of the electron bunches can be controlled by varying the parameters of the SGA process. Possibilities of x-ray intensity increase are also discussed

  15. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  16. X-ray lasers

    CERN Document Server

    Elton, Raymond C

    2012-01-01

    The first in its field, this book is both an introduction to x-ray lasers and a how-to guide for specialists. It provides new entrants and others interested in the field with a comprehensive overview and describes useful examples of analysis and experiments as background and guidance for researchers undertaking new laser designs. In one succinct volume, X-Ray Lasers collects the knowledge and experience gained in two decades of x-ray laser development and conveys the exciting challenges and possibilities still to come._Add on for longer version of blurb_M>The reader is first introduced

  17. X-ray apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Stagg, L.; Lambert, T.W.; Griswa, P.J.

    1976-01-01

    A patient support system for X-ray equipment in arteriographic studies of the heart is described in detail. The support system has been designed to overcome many of the practical problems encountered in using previous types of arteriographic X-ray equipment. The support system is capable of horizontal movement and, by a series of shafts attached to the main support system, the X-ray source and image intensifier or detector may be rotated through the same angle. The system is highly flexible and details are given of several possible operational modes. (U.K.)

  18. X-ray detector

    International Nuclear Information System (INIS)

    Whetten, N.R.; Houston, J.M.

    1977-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of x-ray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes. 8 figures

  19. X-ray apparatus

    International Nuclear Information System (INIS)

    Grady, J.K.

    1985-01-01

    X-ray apparatus is described which has a shutter between the X-ray source and the patient. The shutter controls the level of radiation to which the patient is exposed instead of merely discontinuing the electric power supplied to the source. When the shutter is opened a radiation sensor senses the level of X-radiation. When a preset quantity of X-radiation has been measured an exposure control closes the shutter. Instead of using the radiation sensor, the integrated power supplied to the anode of the X-ray source may be measured. (author)

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  2. X-ray examination apparatus

    NARCIS (Netherlands)

    2000-01-01

    The invention relates to an X-ray apparatus which includes an adjustable X-ray filter. In order to adjust an intensity profile of the X-ray beam, an X-ray absorbing liquid is transported to filter elements of the X-ray filter. Such transport is susceptible to gravitational forces which lead to an

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  4. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  6. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  7. Modern X-ray difraction. X-ray diffractometry for material scientists, physicists, and chemicists

    International Nuclear Information System (INIS)

    Spiess, L.; Schwarzer, R.; Behnken, H.; Teichert, G.

    2005-01-01

    The book yields a comprehensive survey over the applications of X-ray diffraction in fields like material techniques, metallurgy, electrotechniques, machine engineering, as well as micro- and nanotechniques. The necessary fundamental knowledge on X-ray diffraction are mediated foundedly and illustratively. Thereby new techniques and evaluation procedures are presented as well as well known methods. The content: Production and properties of X radiation, diffraction of X radiation, hardware for X-ray diffraction, methods of X-ray diffraction, lattice-constant determination, phase analysis, X-ray profile analysis, crystal structure analysis, X-ray radiographic stress analysis, X-ray radiographic texture analysis, crystal orientation determination, pecularities at thin films, small angle scattering

  8. X-ray Observations at Gaisberg Tower

    Directory of Open Access Journals (Sweden)

    Pasan Hettiarachchi

    2018-01-01

    Full Text Available We report the occurrence of X-rays at ground level due to cloud-to-ground flashes of upward-initiated lightning from Gaisberg Tower, in Austria, which is located at an altitude of 1300 m. This is the first observation of X-ray emissions from upward lightning from a tower top located at high altitude. Measurements were carried out using scintillation detectors installed close to the tower top in two phases from 2011 to 2015. X-rays were recorded in three subsequent strokes of three flashes out of the total of 108 flashes recorded in the system during both phases. In contrast to the observations from downward natural or triggered lightning, X-rays were observed only within 10 µs before the subsequent return stroke. This shows that X-rays were emitted when the dart leader was in the vicinity of the tower top, hence during the most intense phase of the dart leader. Both the detected energy and the fluence of X-rays are far lower compared to X-rays from downward natural or rocket-triggered lightning. In addition to the above 108 flashes, an interesting observation of X-rays produced by a nearby downward flash is also presented. The shorter length of dart-leader channels in Gaisberg is suggested as a possible cause of this apparently weaker X-ray production.

  9. APPLICATION OF THE X-RAY STRUCTURE ANALYSIS FOR IMPROVEMENT OF TECHNOLOGICAL PROCES- SES OF WIRE PRODUCTION AT BMZ

    Directory of Open Access Journals (Sweden)

    D. V. Kuznetsov

    2012-01-01

    Full Text Available The X-ray diffraction methods of qualitative and quantative analysis of phase composition of the brass coating, scale on the surface of brass wire, rod, patented wire, methods of determining the characteristics of the microstrains the lattice ferritic matrix pearlitic high-carbon steel, are explored.

  10. Chest X-Ray

    Medline Plus

    Full Text Available ... Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey ...

  11. Chest X-Ray

    Medline Plus

    Full Text Available ... also be useful to help diagnose and monitor treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  12. X-ray tubes

    International Nuclear Information System (INIS)

    Young, R.W.

    1979-01-01

    A form of x-ray tube is described which provides satisfactory focussing of the electron beam when the beam extends for several feet from gun to target. Such a tube can be used for computerised tomographic scanning. (UK)

  13. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  14. Chest X-Ray

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  15. Chest X-Ray

    Medline Plus

    Full Text Available ... accurate diagnosis far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  16. Chest X-Ray

    Medline Plus

    Full Text Available ... Site Index A-Z Spotlight Recently posted: Pancreatic Cancer The Limitations of Online Dose Calculators Video: The ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  17. Chest X-Ray

    Medline Plus

    Full Text Available ... exams and use a very small dose of ionizing radiation to produce pictures of the inside of the ... chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  18. Chest X-Ray

    Medline Plus

    Full Text Available ... However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs any risk. ...

  19. Chest X-Ray

    Medline Plus

    Full Text Available ... June is Men's Health Month Recently posted: Pancreatic Cancer The Limitations of Online Dose Calculators Video: The ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  20. X-ray sources

    International Nuclear Information System (INIS)

    Masswig, I.

    1986-01-01

    The tkb market survey comparatively evaluates the X-ray sources and replacement tubes for stationary equipment currently available on the German market. It lists the equipment parameters of 235 commercially available X-ray sources and their replacement tubes and gives the criteria for purchase decisions. The survey has been completed with December 1985, and offers good information concerning medical and technical aspects as well as those of safety and maintenance. (orig.) [de

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of knee x-rays. A portable x-ray machine is a compact apparatus that can be taken ... of the body being examined, an x-ray machine produces a small burst of radiation that passes ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ... x-rays. A Word About Minimizing Radiation Exposure Special care is taken during x-ray examinations to ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  7. SPHINX: a generator based on 1 microsecond current rise time LTD stages. Status and first results for production of soft X-ray radiation

    International Nuclear Information System (INIS)

    Mangeant, Ch.; Roques, B.; Cadiergues, R.

    2005-01-01

    SPHINX is the new name of the facility developed for soft X-ray production. This facility is based on the ECF2 generator which was designed as a 1-3 MJ, 1 μs rise time, 5-10 MA current driver. We present a detailed view of the technology used for the capacitor bank, for the central vacuum part and for the Z-pinch loads [ru

  8. Titanium K-Shell X-Ray Production from High Velocity Wire Arrays Implosions on the 20-MA Z Accelerator

    International Nuclear Information System (INIS)

    Apruzese, J.P.; Beg, F.N.; Clark, R.C.; Coverdale, C.A.; Davis, J.; Deeney, C.; Douglas, M.R.; Nash, T.J.; Ruiz-Comacho, J.; Spielman, R.B.; Struve, K.W.; Thornhill, J.W.; Whitney, K.G.

    1999-01-01

    The advent of the 20-MA Z accelerator [R.B. Spielman, C. Deeney, G.A. Chandler, et al., Phys. Plasmas 5, 2105, (1997)] has enabled implosions of large diameter, high-wire-number arrays of titanium to begin testing Z-pinch K-shell scaling theories. The 2-cm long titanium arrays, which were mounted on a 40-mm diameter, produced between 75±15 to 125±20 kJ of K-shell x-rays. Mass scans indicate that, as predicted, higher velocity implosions in the series produced higher x-ray yields. Spectroscopic analyses indicate that these high velocity implosions achieved peak electron temperatures from 2.7±0.1 to 3.2±0.2 keV and obtained a K-shell emission mass participation of up to 12%

  9. Microjet formation and hard x-ray production from a liquid metal target irradiated by intense femtosecond laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Lar' kin, A., E-mail: alexeylarkin@yandex.ru; Uryupina, D.; Ivanov, K.; Savel' ev, A., E-mail: abst@physics.msu.ru [International Laser Center and Faculty of Physics, Lomonosov Moscow State University, Moscow 119991 (Russian Federation); Bonnet, T.; Gobet, F.; Hannachi, F.; Tarisien, M.; Versteegen, M. [Centre d' Études Nucléaires de Bordeaux-Gradignan, University of Bordeaux-CNRS-IN2P3, 33170 Gradignan (France); Spohr, K. [School of Engineering, University of the West of Scotland, Paisley, Scotland PA1 2BE (United Kingdom); Breil, J.; Chimier, B.; Dorchies, F.; Fourment, C.; Leguay, P.-M.; Tikhonchuk, V. T. [Centre Lasers Intenses et Applications, University of Bordeaux-CNRS-CEA, Talence 33405 (France)

    2014-09-15

    By using a liquid metal as a target one may significantly enhance the yield of hard x-rays with a sequence of two intense femtosecond laser pulses. The influence of the time delay between the two pulses is studied experimentally and interpreted with numerical simulations. It was suggested that the first arbitrary weak pulse produces microjets from the target surface, while the second intense pulse provides an efficient electron heating and acceleration along the jet surface. These energetic electrons are the source of x-ray emission while striking the target surface. The microjet formation is explained based on the results given by both optical diagnostics and hydrodynamic modeling by a collision of shocks originated from two distinct zones of laser energy deposition.

  10. Microjet formation and hard x-ray production from a liquid metal target irradiated by intense femtosecond laser pulses

    International Nuclear Information System (INIS)

    Lar'kin, A.; Uryupina, D.; Ivanov, K.; Savel'ev, A.; Bonnet, T.; Gobet, F.; Hannachi, F.; Tarisien, M.; Versteegen, M.; Spohr, K.; Breil, J.; Chimier, B.; Dorchies, F.; Fourment, C.; Leguay, P.-M.; Tikhonchuk, V. T.

    2014-01-01

    By using a liquid metal as a target one may significantly enhance the yield of hard x-rays with a sequence of two intense femtosecond laser pulses. The influence of the time delay between the two pulses is studied experimentally and interpreted with numerical simulations. It was suggested that the first arbitrary weak pulse produces microjets from the target surface, while the second intense pulse provides an efficient electron heating and acceleration along the jet surface. These energetic electrons are the source of x-ray emission while striking the target surface. The microjet formation is explained based on the results given by both optical diagnostics and hydrodynamic modeling by a collision of shocks originated from two distinct zones of laser energy deposition

  11. Microjet formation and hard x-ray production from a liquid metal target irradiated by intense femtosecond laser pulses

    Science.gov (United States)

    Lar'kin, A.; Uryupina, D.; Ivanov, K.; Savel'ev, A.; Bonnet, T.; Gobet, F.; Hannachi, F.; Tarisien, M.; Versteegen, M.; Spohr, K.; Breil, J.; Chimier, B.; Dorchies, F.; Fourment, C.; Leguay, P.-M.; Tikhonchuk, V. T.

    2014-09-01

    By using a liquid metal as a target one may significantly enhance the yield of hard x-rays with a sequence of two intense femtosecond laser pulses. The influence of the time delay between the two pulses is studied experimentally and interpreted with numerical simulations. It was suggested that the first arbitrary weak pulse produces microjets from the target surface, while the second intense pulse provides an efficient electron heating and acceleration along the jet surface. These energetic electrons are the source of x-ray emission while striking the target surface. The microjet formation is explained based on the results given by both optical diagnostics and hydrodynamic modeling by a collision of shocks originated from two distinct zones of laser energy deposition.

  12. X-Ray Absorption with Transmission X-Ray Microscopes

    NARCIS (Netherlands)

    de Groot, F.M.F.

    2016-01-01

    In this section we focus on the use of transmission X-ray microscopy (TXM) to measure the XAS spectra. In the last decade a range of soft X-ray and hard X-ray TXM microscopes have been developed, allowing the measurement of XAS spectra with 10–100 nm resolution. In the hard X-ray range the TXM

  13. Radiative electron capture into the K-, L-, and M-shell of decelerated, hydrogenic Ge projectiles

    International Nuclear Information System (INIS)

    Stoehlker, T.; Kozhuharov, C.; Livingston, A.E.; Mokler, P.H.; Stachura, Z.; Warczak, A.

    1991-12-01

    Radiative Electron Capture (REC) in 4 to 12 MeV/u Ge 31+ →H 2 collisions has been studied using an X-ray/particle coincidence technique. This technique allowed a systematic investigation of K-shell REC as well as a separation of REC into the projectile L- and M-shells. The cross sections are discussed within a general scaling picture based on the reduced projectile velocity. (orig.)

  14. Production of X-rays by inverse Compton effect; Produccion de rayos X por efecto Compton inverso

    Energy Technology Data Exchange (ETDEWEB)

    Mainardi, R.T. [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina)

    2005-07-01

    X-rays and gamma rays of high energy values can be produced by the scattering of low energy photons with high energy electrons, being this a process controlled by the Compton scattering. If a laser beam is used, the x-ray beam inherits the properties of intensity, monochromaticity and collimation from the laser. In this work we analyze the generation of intense x-ray beams of energies between 10 and 100 KeV to be used in a wide range of applications where a high intensity and high degrees of monochromaticity and polarization are important properties to improve image reduce doses and improve radiation treatments. To this purpose we evaluated, using relativistic kinematics the scattered beam properties in terms of the scattering angle. This arrangement is being considered in several worldwide laboratories as an alternative to synchrotron radiation and is referred to as 'table top synchrotron radiation', since it cost of installation is orders of magnitude smaller than a 'synchrotron radiation source'. The radiation beam might exhibit non-linear properties in its interaction with matter, in a similar way as a laser beam and we will investigate how to calibrate and evaluate TLD dosemeters properties, both in low and high intensity fields either mono or polyenergetic in wide spectral energy ranges. (Author)

  15. Towards tabletop production of intense quasimonochromatic X-ray beams using small 2-20 MeV accelerators

    International Nuclear Information System (INIS)

    Avakian, R.O.; Ispirian, K.A.

    2004-01-01

    Full text: The existing synchrotron radiation sources and the fourth generation x-ray sources, which are projected at SLAC, USA, and DESY, Germany, are very expensive. For this reason the search of the novel and cheaper sources using various types of radiation produced by 5-20 MeV electrons available at many hospitals, universities and firms in various countries is of great interest. In this article a review of the physics, history, new theoretical and experimental results and of some applications is given with a purpose to consider the possibilities of construction of small tabletop sources of quasimonochromatic X-ray photon beams necessary for scientific, industrial, medicine and other applications. Simple formulae for almost all types of radiation are given with the help of which one can estimate the expected useful yield and background. PACS: 41.60.-m; 43.35.Ty; 61.85+p;m 78.67.Pt; 78.70.-g. Key words: Bremsstrahlung/Cherenkov radiation/ Transition radiation / Parametric X-ray radiation / Channeling radiation/ Compton scattering

  16. L-shell x-ray yields and production cross-sections of molybdenum induced by low-energy highly charged argon ions

    International Nuclear Information System (INIS)

    Du Juan; Xu Jinzhang; Chen Ximeng; Yang Zhihu; Shao Jianxiong; Cui Ying; Zhang Hongqiang; Gao Zhimin; Liu Yuwen

    2007-01-01

    L-shell x-ray yields of molybdenum bombarded by highly charged Ar q+ ions (q=11-16) are measured. The x-ray production cross-sections are extracted from the yields data. The energy of the incident Ar ions ranges from 200 to 350 keV. After the binding energy correction, experimental data are explained in the framework of binary-encounter-approximation (BEA). The direct ionization is treated in the united atom (UA) limit (Lapicki and Lichten 1985 Phys. Rev. A 31 1354), not in the separate atom (SA) limit. The calculation results of BEA (Gacia and Fortner 1973 Rev. Mod. Phys. 45 111) are much lower than the experimental results, while the results of binding energy modified BEA are basically in agreement with the experimental results

  17. Studies on production of metastable core-excited atoms by laser-produced x-rays. Final report, 1 October 1984-30 September 1985

    International Nuclear Information System (INIS)

    Harris, S.E.; Young, J.F.

    1986-04-01

    The overall objective of the work on this program was to study methods for production of core-excited metastable atoms by laser-generated x-rays. We are interested in the spectroscopy of these levels, their autoionizing and radiative rates, and their metastability in the presence of hot electrons and ions. The concept of using x-rays emitted from a laser-produced plasma to excite large densities of energetic excited levels in atoms and ions has been thoroughly experimentally investigated using modest, 100 mJ, plasma-producing lasers. One of the objectives of this work was to verify that these techniques could be scaled up to higher energies, such as 20 J. Thus a major effort this year has been devoted to the design and construction of the high energy (20 J) 1064 nm plasma-forming laser system and the tunable probe/transfer laser

  18. Measurements of L-shell x-ray production cross-sections of Au and Ag by low energy electron impact

    International Nuclear Information System (INIS)

    Wu, Y; An, Z; Liu, M T; Duan, Y M; Tang, C H; Luo, Z M

    2004-01-01

    Au L α and L β and Ag L-shell x-ray production cross-sections by electron impact have been measured in the incident energy region from near threshold to about 25 keV. Thin films with thick aluminium substrates were used as targets in the experiments. The effect of directional and energy spreading of the electron beam within the active films and x-ray enhancement due to backscattering electrons and bremsstrahlung photons from the substrates are corrected by means of Monte Carlo simulations. The corrected experimental data provided by this method are compared with calculated cross-sections from a PWBA theory with Coulomb, relativistic and exchange corrections and with other experimental data available in the literature

  19. Accelerator-driven X-ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Dinh Cong [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-09

    After an introduction which mentions x-ray tubes and storage rings and gives a brief review of special relativity, the subject is treated under the following topics and subtopics: synchrotron radiation (bending magnet radiation, wiggler radiation, undulator radiation, brightness and brilliance definition, synchrotron radiation facilities), x-ray free-electron lasers (linac-driven X-ray FEL, FEL interactions, self-amplified spontaneous emission (SASE), SASE self-seeding, fourth-generation light source facilities), and other X-ray sources (energy recovery linacs, Inverse Compton scattering, laser wakefield accelerator driven X-ray sources. In summary, accelerator-based light sources cover the entire electromagnetic spectrum. Synchrotron radiation (bending magnet, wiggler and undulator radiation) has unique properties that can be tailored to the users’ needs: bending magnet and wiggler radiation is broadband, undulator radiation has narrow spectral lines. X-ray FELs are the brightest coherent X-ray sources with high photon flux, femtosecond pulses, full transverse coherence, partial temporal coherence (SASE), and narrow spectral lines with seeding techniques. New developments in electron accelerators and radiation production can potentially lead to more compact sources of coherent X-rays.

  20. X-ray tube

    International Nuclear Information System (INIS)

    Webley, R.S.

    1975-01-01

    The object of the invention described is to provide an X-ray tube providing a scanned X-ray output which does not require a scanned electron beam. This is obtained by an X-ray tube including an anode which is rotatable about an axis, and a source of a beam of energy, for example an electron beam, arranged to impinge on a surface of the anode to generate X-radiation substantially at the region of incidence on the anode surface. The anode is rotatable about the axis to move the region of incidence over the surface. The anode is so shaped that the rotation causes the region of incidence to move in a predetermined manner relative to fixed parts of the tube so that the generated X-radiation is scanned in a predetermined manner relative to the tube. (UK)

  1. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Setti, G.

    1980-01-01

    This book contains the lectures, and the most important seminars held at the NATO meeting on X-Ray astronomy in Erice, July 1979. The meeting was an opportune forum to discuss the results of the first 8-months of operation of the X-ray satellite, HEAO-2 (Einstein Observatory) which was launched at the end of 1978. Besides surveying these results, the meeting covered extragalactic astronomy, including the relevant observations obtained in other portions of the electromagnetic spectrum (ultra-violet, optical, infrared and radio). The discussion on galactic X-ray sources essentially covered classical binaries, globular clusters and bursters and its significance to extragalactic sources and to high energy astrophysics was borne in mind. (orig.)

  2. A Scanning Transmission X-ray Microscopy Study of Cubic and Orthorhombic C3A and Their Hydration Products in the Presence of Gypsum

    Directory of Open Access Journals (Sweden)

    Vanessa Rheinheimer

    2016-08-01

    Full Text Available This paper shows the microstructural differences and phase characterization of pure phases and hydrated products of the cubic and orthorhombic (Na-doped polymorphs of tricalcium aluminate (C3A, which are commonly found in traditional Portland cements. Pure, anhydrous samples were characterized using scanning transmission X-ray microscopy (STXM, X-ray photoelectron spectroscopy (XPS and X-ray diffraction (XRD and demonstrated differences in the chemical and mineralogical composition as well as the morphology on a micro/nano-scale. C3A/gypsum blends with mass ratios of 0.2 and 1.9 were hydrated using a water/C3A ratio of 1.2, and the products obtained after three days were assessed using STXM. The hydration process and subsequent formation of calcium sulfate in the C3A/gypsum systems were identified through the changes in the LIII edge fine structure for Calcium. The results also show greater Ca LII binding energies between hydrated samples with different gypsum contents. Conversely, the hydrated samples from the cubic and orthorhombic C3A at the same amount of gypsum exhibited strong morphological differences but similar chemical environments.

  3. Flash x-ray

    International Nuclear Information System (INIS)

    Johnson, Q.; Pellinen, D.

    1976-01-01

    The complementary techniques of flash x-ray radiography (FXR) and flash x-ray diffraction (FXD) provide access to a unique domain in nondestructive materials testing. FXR is useful in studies of macroscopic properties during extremely short time intervals, and FXD, the newer technique, is used in studies of microscopic properties. Although these techniques are similar in many respects, there are some substantial differences. FXD generally requires low-voltage, line-radiation sources and extremely accurate timing; FXR is usually less demanding. Phenomena which can be profitably studied by FXR often can also be studied by FXD to permit a complete materials characterization

  4. X-ray astronomy

    International Nuclear Information System (INIS)

    Narayanan, M.S.

    1976-01-01

    The deployment of detectors outside the deleterious effects of the atmosphere by sending them in space vehicles, has been explained. This has thrown open the entire spectrum of the electromagnetic and particle radiation to direct observations, thus enlarging the vistas of the field of astronomy and astrophysics. The discovery of strong emitters of X-rays such as SCO X-1, NorX-2, transient sources such as Cen X-2, Cen X-4, Cen X-1, Supernova remnants Tan X-1, etc., are reported. The background of the X-ray spectrum as measured during two rocket flights over Thumba, India is presented. (K.B.)

  5. X-ray masks

    International Nuclear Information System (INIS)

    Greenwood, J.C.; Satchell, D.W.

    1984-01-01

    In semiconductor manufacture, where X-ray irradiation is used, a thin silicon membrane can be used as an X-ray mask. This membrane has areas on which are patterns to define the regions to be irradiated. These regions are of antireflection material. With the thin, in the order of 3 microns, membranes used, fragility is a problem. Hence a number of ribs of silicon are formed integral with the membrane, and which are relatively thick, 5 to 10 microns. The ribs may be formed by localised deeper boron deposition followed by a selective etch. (author)

  6. X-ray detector

    International Nuclear Information System (INIS)

    Houston, J.M.; Whetten, N.R.

    1981-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of xray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes

  7. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small dose of ... x-ray , is a two-dimensional (2-D) dental x-ray examination that captures the entire mouth ...

  8. Subluminous X-ray binaries

    NARCIS (Netherlands)

    Armas Padilla, M.

    2013-01-01

    The discovery of the first X-ray binary, Scorpius X-1, by Giacconi et al. (1962), marked the birth of X-ray astronomy. Following that discovery, many additional X-ray sources where found with the first generation of X-ray rockets and observatories (e.g., UHURU and Einstein). The short-timescale

  9. X-Ray Exam: Pelvis

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Pelvis KidsHealth / For Parents / X-Ray Exam: ... Ray Exam: Hip Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  10. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  11. X-Ray Exam: Foot

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  12. X-Ray Exam: Wrist

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  13. Thoracic spine x-ray

    Science.gov (United States)

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  14. X-Ray Exam: Finger

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  15. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  16. X rays and condensed matter

    International Nuclear Information System (INIS)

    Daillant, J.

    1997-01-01

    After a historical review of the discovery and study of X rays, the various interaction processes between X rays and matter are described: Thomson scattering, Compton scattering, X-photon absorption through photoelectric effect, and magnetic scattering. X ray sources such as the European Synchrotron Radiation Facility (ESRF) are described. The various X-ray applications are presented: imagery such as X tomography, X microscopy, phase contrast; X-ray photoelectron spectroscopy and X-ray absorption spectroscopy; X-ray scattering and diffraction techniques

  17. Efficient laser-induced 6-8 keV x-ray production from iron oxide aerogel and foil-lined cavity targets

    Energy Technology Data Exchange (ETDEWEB)

    Pérez, F.; Kay, J. J.; Patterson, J. R.; Kane, J.; Villette, B.; Girard, F.; Reverdin, C.; May, M.; Emig, J.; Sorce, C.; Colvin, J.; Gammon, S.; Jaquez, J.; Satcher, J. H.; Fournier, K. B.

    2012-08-01

    The performance of new iron-based laser-driven x-ray sources has been tested at the OMEGA laser facility for production of x rays in the 6.5–8.5 keV range. Two types of targets were experimentally investigated: low-density iron oxide aerogels (density 6-16 mg/cm36-16 mg/cm3) and stainless steel foil-lined cavity targets (steel thickness 1-5 μm1-5 μm). The targets were irradiated by 40 beams of the OMEGA laser (500 J/beam, 1 ns pulse, wavelength 351 nm). All targets showed good coupling with the laser, with <5%<5% of the incident laser light backscattered by the resulting plasma in all cases (typically <2.5%<2.5%). The aerogel targets produced Te=2Te=2 to 3 keV, ne=0.12-0.2ne=0.12-0.2 critical density plasmas yielding a 40%–60% laser-to-x-ray total conversion efficiency (CE) (1.2%–3% in the Fe K-shell range). The foil cavity targets produced Te~2 keV, Te~2 keV, ne~0.15ne~0.15 critical density plasmas yielding a 60%–75% conversion efficiency (1.6%–2.2% in the Fe K-shell range). Time-resolved images illustrate that the volumetric heating of low-density aerogels allow them to emit a higher K-shell x-ray yield even though they contain fewer Fe atoms. However, their challenging fabrication process leads to a larger shot-to-shot variation than cavity targets.

  18. X-ray beam generator

    International Nuclear Information System (INIS)

    Koller, T.J.; Randmer, J.A.

    1977-01-01

    A method of minimizing the preferential angular absorption of the divergent beam from an X-ray generator is described. The generator consists of an X-ray shielded housing with an X-ray transmissive window symmetrically placed in radial alignment with a focal spot area on a sloped target surface of an X-ray tube in the housing. The X-ray tube may be of the stationary anode type or of the rotating anode type. (U.K.)

  19. Nonlinear X-ray production of defect spins in vitreous SiO2: the roles of creation and activation

    International Nuclear Information System (INIS)

    Galeener, F.L.; Kerwin, D.B.; Miller, A.J.

    1992-01-01

    The dependence of spin concentration on X-ray dose is shown to be nonlinear in distinctive ways for the three most common defect structures in vitreous SiO 2 . We fit the data with a model invoking two concurrent simple processes: creation of new defects and activation of preexisting ones. The resultant fit parameters show dependencies on hydroxyl concentration and fictive temperature that shed new light on the processes, the defects, their origins and the radiation hardness of v-SiO 2 . (author)

  20. Chest X-Ray

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... x-ray is used to evaluate the lungs, heart and chest wall and may be used to ...

  1. Medical x-ray

    International Nuclear Information System (INIS)

    Abd Aziz Mhd Ramli; Gui Ah Auu; Husaini Salleh; Idris Besar; Mohd Ashhar Khalid; Muhammad Jamal Md Isa; Shaharuddin Mohd; Siti Najila Mohd Janib; Mohamed Ali Abdul Khader; Mahalatchimi Dave; Mohd Fazly Abdul Rahim; Ng Chee Moon; Ram Piari; Teoh Hoon Heng; Lee Peter

    2004-01-01

    This book describes the fundamental subject about medical radiography. It is a multidisciplinary field that requires cross professional input from scientists, engineers and medical doctors. However, it is presented in simple language to suit different levels of readers from x-ray operators and radiographers to physists, general practitioners and radiology specialists.The book is written in accordance to the requirements of the standard syllabus approved by the Ministry of Health Malaysia for the training of medical x-ray operator and general practitioners. In general, the content is not only designed to provide relevant and essential subject for related professionals in medical radiological services such as x-ray operator, radiographer and radiologists, but also to address those in associated radiological services including nurses, medical technologists and physicists.The book is organized and arranged sequentially into 3 parts for easy reference: Radiation safety; X-ray equipment and associated facilities; Radiography practices. With proper grasping of all these parts, the radiological services could be provided with confident and the highest professional standard. Thus, medical imaging with highest quality that can provide useful diagnostic information at minimum doses and at cost effective could be assured

  2. Chest X-Ray

    Medline Plus

    Full Text Available ... change into a gown. You may have some concerns about chest x-rays. However, it’s important to ... You Sponsored by About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  3. Cloning, recombinant production, crystallization and preliminary X-ray diffraction analysis of SDF2-like protein from Arabidopsis thaliana

    International Nuclear Information System (INIS)

    Radzimanowski, Jens; Ravaud, Stephanie; Schott, Andrea; Strahl, Sabine; Sinning, Irmgard

    2009-01-01

    Overexpression, purification, crystallization and preliminary X-ray diffraction of the stromal-cell-derived factor 2-like protein of Arabidopsis thaliana are reported. The crystals belonged to the space group P6 1 and diffracted to 1.95 Å resolution. The stromal-cell-derived factor 2-like protein of Arabidopsis thaliana (AtSDL) has been shown to be highly up-regulated in response to unfolded protein response (UPR) inducing reagents, suggesting that it plays a crucial role in the plant UPR pathway. AtSDL has been cloned, overexpressed, purified and crystallized using the vapour-diffusion method. Two crystal forms have been obtained under very similar conditions. The needle-shaped crystals did not diffract X-rays, while the other form diffracted to 1.95 Å resolution using a synchrotron-radiation source and belonged to the hexagonal space group P6 1 , with unit-cell parameters a = b = 96.1, c = 69.3 Å

  4. Production of haploid plant of 'Banpeiyu' pummelo [Citrus maxima (Burm.) Merr.] by pollination with soft X-ray-irradiated pollen

    International Nuclear Information System (INIS)

    Yahata, Masaki; Yasuda, Kiichi; Kunitake, Hisato; Nagasawa, Kohji; Harusaki, Seiichi; Komatsu, Haruki

    2010-01-01

    To induce haploid plants in Citrus maxima (Burm.) Merr. 'Banpeiyu', we evaluated the effect of pollination with soft X-ray-irradiated pollen on fruit set and seed development, and carried out ovule culture. When 'Banpeiyu' pummelo pistils were pollinated with X-ray-irradiated pollen of 'Fukuhara' sweet orange [C. sinensis (L.) Osbeck], the exposure doses affected the fruit set. The number of seeds per fruit was also affected by the exposure dose, and tended to decrease as the dose increased; however, all developed seeds obtained from these crosses were diploid. In the ovule culture of 'Banpeiyu' pummelo, six embryoids shown haploidy were obtained in all treatments. One haploid plantlet with 9 chromosomes was regenerated from an embryoid in a culture of ovules established 40 days after pollination with 400 Gray (Gy)-irradiated pollen of 'Tosa-buntan' pummelo (C. maxima). This haploid was suggested to be derived from 'Banpeiyu' pummelo by random amplified polymorphic DNA (RAPD) and cleaved amplified polymorphic sequence (CAPS) analysis. (author)

  5. Development and production of a multilayer-coated x-ray reflecting stack for the Athena mission

    Science.gov (United States)

    Massahi, S.; Ferreira, D. D. M.; Christensen, F. E.; Shortt, B.; Girou, D. A.; Collon, M.; Landgraf, B.; Barriere, N.; Krumrey, M.; Cibik, L.; Schreiber, S.

    2016-07-01

    The Advanced Telescope for High-Energy Astrophysics, Athena, selected as the European Space Agency's second large-mission, is based on the novel Silicon Pore Optics X-ray mirror technology. DTU Space has been working for several years on the development of multilayer coatings on the Silicon Pore Optics in an effort to optimize the throughput of the Athena optics. A linearly graded Ir/B4C multilayer has been deposited on the mirrors, via the direct current magnetron sputtering technique, at DTU Space. This specific multilayer, has through simulations, been demonstrated to produce the highest reflectivity at 6 keV, which is a goal for the scientific objectives of the mission. A critical aspect of the coating process concerns the use of photolithography techniques upon which we will present the most recent developments in particular related to the cleanliness of the plates. Experiments regarding the lift-off and stacking of the mirrors have been performed and the results obtained will be presented. Furthermore, characterization of the deposited thin-films was performed with X-ray reflectometry at DTU Space and in the laboratory of the Physikalisch-Technische Bundesanstalt at the synchrotron radiation facility BESSY II.

  6. Recombinant production, crystallization and preliminary X-ray analysis of PCNA from the psychrophilic archaeon Methanococcoides burtonii DSM 6242

    International Nuclear Information System (INIS)

    Byrne-Steele, Miranda L.; Hughes, Ronny C.; Ng, Joseph D.

    2009-01-01

    The proliferating cell nuclear antigen (PCNA) from the eurypsychrophilic archaeon M. burtonii DSM 6242 has been cloned, overproduced, purified and crystallized. Crystals were deemed to be suitable for X-ray analysis and structure determination to 2.40 Å resolution. Proliferating cell nuclear antigen (PCNA) is a DNA-clamping protein that is responsible for increasing the processivity of the replicative polymerases during DNA replication and repair. The PCNA from the eurypsychrophilic archaeon Methanococcoides burtonii DSM 6242 (MbPCNA) has been targeted for protein structural studies. A recombinant expression system has been created that overproduces MbPCNA with an N-terminal hexahistidine affinity tag in Escherichia coli. As a result, recombinant MbPCNA with a molecular mass of 28.3 kDa has been purified to at least 95% homogeneity and crystallized by vapor-diffusion equilibration. Preliminary X-ray analysis revealed a trigonal hexagonal R3 space group, with unit-cell parameters a = b = 102.5, c = 97.5 Å. A single MbPCNA crystal was subjected to complete diffraction data-set collection using synchrotron radiation and reflections were measured to 2.40 Å resolution. The diffraction data were of suitable quality for indexing and scaling and an unrefined molecular-replacement solution has been obtained

  7. Lambda bacteriophage gene products and x-ray sensitivity of Escherichia coli: comparison of red-dependent and gam-dependent radioresistance

    International Nuclear Information System (INIS)

    Trgovcevic, Z.; Rupp, W.D.

    1975-01-01

    When gene products of lambda bacteriophage are introduced into a cell by transient induction of a lysogen, increased resistance of the cells to x rays results. This phenomenon has been called phage-induced radioresistance. Genetic studies show at least two classes of induced radioresistance. The first type depends on the products of the lambda red genes and is observed in bacteria that are mutated in the recB gene. It is thought that the lambda red products compensate for the missing RecBC nuclease in the repair of x-ray damage. An optimal effect is obtained even when the lambda red products are supplied 1 h after irradiation. The lesions that are affected by the red-dependent process are probably not deoxyribonucleic acid strand breaks because the extent of deoxyribonucleic acid strand rejoining is not altered by the red products. The second type of phage-induced radioresistance requires the gam product of lambda and is observed in wild-type and polA strains. The lambda gam + gene product must be present immediately after irradiation to exert its full effect. In its presence, DNA breakdown is decreased, and a greater fraction of DNA is converted back to high molecular weight. Strains carrying lex, recA, or certain other combinations of mutations do not show any detectable phage-induced radioresistance. (U.S.)

  8. ASM Inaugural Lecture 2010: Single crystal X-ray structural determination: A powerful technique for natural products research and drug discovery

    International Nuclear Information System (INIS)

    Fun Hoong Kun; Chantrapromma, S.; Boonnak, N.; Lee, V.S.

    2010-01-01

    Drug discovery from natural products resources have been extensively studied worldwide because natural products with their great structural diversity have traditionally provided most of the drugs in use. They offer major opportunities for finding novel low molecular weight leading-structures that are active against a wide range of assay targets. The most important step in the discovery process is the identification of compounds with interesting biological activity. Single crystal X-ray structure determination is a powerful technique for natural products research and drug discovery. The detailed three-dimensional structures that emerge can be co-related to the activities to these structures. In this article the following is presented: (i) co-crystal and disorder structures; (ii) determination of absolute configuration and (iii) the ability to distinguish between whether a natural product compound is a natural product or a natural product artifact. All these three properties are unique to the technique of single crystal X-ray structure determination. Case (iii) was demonstrated with a compound containing a chromene ring, namely macluraxanthone (which was isolated from Cratoxylum formosum subsp. pruniflorum, a Thai medicinal plant). (author)

  9. X-ray filter for x-ray powder diffraction

    Science.gov (United States)

    Sinsheimer, John Jay; Conley, Raymond P.; Bouet, Nathalie C. D.; Dooryhee, Eric; Ghose, Sanjit

    2018-01-23

    Technologies are described for apparatus, methods and systems effective for filtering. The filters may comprise a first plate. The first plate may include an x-ray absorbing material and walls defining first slits. The first slits may include arc shaped openings through the first plate. The walls of the first plate may be configured to absorb at least some of first x-rays when the first x-rays are incident on the x-ray absorbing material, and to output second x-rays. The filters may comprise a second plate spaced from the first plate. The second plate may include the x-ray absorbing material and walls defining second slits. The second slits may include arc shaped openings through the second plate. The walls of the second plate may be configured to absorb at least some of second x-rays and to output third x-rays.

  10. X-ray refractometer

    International Nuclear Information System (INIS)

    Tur'yanskij, A.G.; Pirshin, I.V.

    2001-01-01

    Paper introduces a new circuit of X-ray refractometer to study angular and spectral features of refracted radiation within hard X-ray range. Refractometer incorporates two goniometers, two crystal-analyzers and three radiation detectors. The maximum distance between radiation source focal point and a receiving slit of the second goniometer is equal to 1.4 m. For the first time one obtained refraction patterns of fine-film specimens including C/Si stressed structure. Paper describes a new technique of refractometry via specimen oscillation at fixed position of a detecting device. Paper presents the measurement results of oscillation refraction patterns for specimens of melted quartz and ZnSe single crystal [ru

  11. X-ray radiotherapy

    International Nuclear Information System (INIS)

    Tronc, D.

    1995-01-01

    Full text: The most common form of radio therapy is X-ray therapy, where a beam of photons or their parent electrons break down hydrogen bonds within the body's cells and remove certain DNA information necessary for cell multiplication. This process can eradicate malignant cells leading to complete recovery, to the remission of some cancers, or at least to a degree of pain relief. The radiotherapy instrument is usually an electron linac, and the electrons are used either directly in 'electrotherapy' for some 10% of patients, or the electrons bombard a conversion target creating a broad beam of high energy photons or 'penetration X-rays'. The simplest machine consists of several accelerating sections at around 3 GHz, accelerating electrons to 6 MeV; a cooled tungsten target is used to produce a 4 Gray/min X-ray field which can be collimated into a rectangular shape at the patient position. This tiny linac is mounted inside a rotating isocentric gantry above the patient who must remain perfectly still. Several convergent beams can also be used to increase the delivered dose. More sophisticated accelerators operate at up to 18 MeV to increase penetration depths and decrease skin exposure. Alternatively, electrotherapy can be used with different energies for lower and variable penetration depths - approximately 0.5 cm per MeV. In this way surface tissue may be treated without affecting deeper and more critical anatomical regions. This type of linac, 1 to 2 metres long, is mounted parallel to the patient with a bending magnet to direct the beam to the radiotherapy system, which includes the target, thick movable collimator jaws, a beam field equalizer, dose rate and optical field simulation and energy controls. There are over 2000 acceleratorbased X-ray treatment units worldwide. Western countries have up to two units per million population, whereas in developing countries such as Bangladesh, the density is only one per 100 million. Several

  12. X-ray generator

    Energy Technology Data Exchange (ETDEWEB)

    Zucarias, A; Shepherd, J W

    1982-09-08

    An X-ray tube has a tubular envelope with a cathode for directing an electron beam onto a focal spot area of a spaced anode target to generate X-rays. The target is mounted for axial rotation on one end of a rotor disposed in an end portion of the envelope and encircled by a stator of an alternating current induction motor. An annular shield of high permeability magnetic material extends transversely between the electron beam and the stator of the induction motor for shunting stray or fringe electromagnetic fields established by the stator away from the electron beam to avoid consequent lateral deflections of the electron and corresponding lateral movements of the focal spot area.

  13. X-ray microtomography

    International Nuclear Information System (INIS)

    Dunsmuir, J.H.; Ferguson, S.R.; D'Amico, K.L.; Stokes, J.P.

    1991-01-01

    In this paper the authors describe the application of a new high-resolution X-ray tomographic microscope to the study of porous media. The microscope was designed to exploit the properties of a synchrotron X-ray source to perform three dimensional tomography on millimeter sized objects with micron resolution and has been used in materials science studies with both synchrotron and conventional and synchrotron sources will be compared. In this work the authors have applied the microscope to measure the three dimensional structure of fused bead packs and berea sandstones with micron resolution and have performed preliminary studies of flow in these media with the microscope operated in a digital subtraction radiography mode. Computer graphics techniques have been applied to the data to visually display the structure of the pore body system. Tomographic imaging after flow experiments should detect the structure of the oil-water interface in the pore network and this work is ongoing

  14. X-ray diffraction

    International Nuclear Information System (INIS)

    Einstein, J.R.; Wei, C.H.

    1982-01-01

    We have been interested in structural elucidation by x-ray diffraction of compounds of biological interest. Understanding exactly how atoms are arranged in three-dimensional arrays as molecules can help explain the relationship between structure and functions. The species investigated may vary in size and shape; our recent studies included such diverse substances as antischistosomal drugs, a complex of cadmium with nucleic acid base, nitrate salts of adenine, and proteins

  15. X-ray apparatus

    International Nuclear Information System (INIS)

    Tomita, Chuji.

    1980-01-01

    A principal object of the present invention is to provide an X-ray apparatus which is such that the distance between the surface of the patient's table and the floor on which the apparatus is installed is sufficiently small in the horizontal position of the patient's table of the roentgenographical pedestal and that the rotation of the pedestal from the horizontal position to a tilted position and further to the vertical position of the table can be carried out smoothly. (auth)

  16. X-ray Ordinance

    International Nuclear Information System (INIS)

    Kramer, R.; Zerlett, G.

    1983-01-01

    This commentary, presented as volume 2 of the Deutsches Strahlenschutzrecht (German legislation on radiation protection) deals with the legal provisions of the ordinance on the protection against harmful effects of X-radiation (X-ray Ordinance - RoeV), of March 1, 1973 (announced in BGBl.I, page 173), as amended by the ordinance on the protection against harmful effects of ionizing radiation, of October 13, 1976 (announced in BGBl. I, page 2905). Thus volume 2 completes the task started with volume 1, namely to present a comprehensive view and account of the body of laws governing radiation protection, a task which was thought useful as developments in the FRG led to regulations being split up into the X-ray Ordinance, and the Radiation Protection Ordinance. In order to present a well-balanced commentary on the X-ray Ordinance, it was necessary to discuss the provisions both from the legal and the medical point of view. This edition takes into account the Fourth Public Notice of the BMA (Fed. Min. of Labour and Social Affairs) concerning the implementation of the X-ray Ordinance of January 4, 1982, as well as court decisions and literature published in this field, until September 1982. In addition, the judgment of the Federal Constitutional Court, dated October 19, 1982, concerning the voidness of the law on government liability, and two decisions by the Federal High Court, dated November 23, 1982, concerning the right to have insight into medical reports - of great significance in practice - have been considered. This commentary therefore is up to date with current developments. (orig.) [de

  17. Producing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.; Jung, R.G.; Applebaum, D.C.; Fairand, B.P.; Gallagher, W.J.

    1977-01-01

    A method of producing x-rays by directing radiant energy from a laser onto a target is described. Conversion efficiency of at least about 3 percent is obtained by providing the radiant energy in a low-power precursor pulse of approximately uniform effective intensity focused onto the surface of the target for about 1 to 30 nanoseconds so as to generate an expanding unconfined coronal plasma having less than normal solid density throughout and comprising a low-density (underdense) region wherein the plasma frequency is less than the laser radiation frequency and a higher-density (overdense) region wherein the plasma frequency is greater than the laser radiation frequency and, about 1 to 30 nanoseconds after the precursor pulse strikes the target, a higher-power main pulse focused onto the plasma for about 10 -3 to 30 nanoseconds and having such power density and total energy that the radiant energy is absorbed in the underdense region and conducted into the overdense region to heat it and thus to produce x-rays therefrom with the plasma remaining substantially below normal solid density and thus facilitating the substantial emission of x-rays in the form of spectral lines arising from nonequilibrium ionization states

  18. Evaluation of components of X-ray irradiated 7-valent pneumococcal conjugate vaccine and pneumococcal vaccine polyvalent and X-ray and gamma-ray irradiated acellular pertussis component of DTaP vaccine products

    International Nuclear Information System (INIS)

    May, J.C.; Rey, L.; Lee, C.-J.; Arciniega, Juan

    2004-01-01

    Samples of pneumococcal vaccine polyvalent, 7-valent pneumococcal conjugate vaccine, and two different diphtheria and tetanus toxoids and acellular pertussis vaccines adsorbed were irradiated with X-rays and/or gamma-rays (Co-60). Mouse IgG and IgM antibody responses (ELISA) for types 9V, 14, 18C, and 19F pneumococcal polysaccharides and conjugates indicated that the polysaccharides were more tolerant of the radiation than the conjugates. The mouse antibody response for the detoxified pertussis toxin (PT) antigen, filamentous hemagglutinin antigen (FHA), pertactin (PRN), and fimbriae types 2 and 3 (FIM) antigens for the appropriate vaccine type indicated that the antibody response was not significantly changed in the 25 kGy X-ray irradiated vaccines frozen in liquid nitrogen compared to the control vaccine

  19. Evaluation of components of X-ray irradiated 7-valent pneumococcal conjugate vaccine and pneumococcal vaccine polyvalent and X-ray and gamma-ray irradiated acellular pertussis component of DTaP vaccine products

    Energy Technology Data Exchange (ETDEWEB)

    May, J.C. E-mail: may@cber.fda.gov; Rey, L. E-mail: louis.rey@bluewin.ch; Lee, C.-J.; Arciniega, Juan

    2004-10-01

    Samples of pneumococcal vaccine polyvalent, 7-valent pneumococcal conjugate vaccine, and two different diphtheria and tetanus toxoids and acellular pertussis vaccines adsorbed were irradiated with X-rays and/or gamma-rays (Co-60). Mouse IgG and IgM antibody responses (ELISA) for types 9V, 14, 18C, and 19F pneumococcal polysaccharides and conjugates indicated that the polysaccharides were more tolerant of the radiation than the conjugates. The mouse antibody response for the detoxified pertussis toxin (PT) antigen, filamentous hemagglutinin antigen (FHA), pertactin (PRN), and fimbriae types 2 and 3 (FIM) antigens for the appropriate vaccine type indicated that the antibody response was not significantly changed in the 25 kGy X-ray irradiated vaccines frozen in liquid nitrogen compared to the control vaccine.

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. A bone ... bones. top of page How should I prepare? Most bone x-rays require no special preparation. You ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... can be taken to the patient in a hospital bed or the emergency room. The x-ray ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  4. X-ray detector array

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    The object of the invention (an ionization chamber X-ray detector array for use with high speed computerised tomographic imaging apparatus) is to reduce the time required to produce a tomographic image. The detector array described determines the distribution of X-ray intensities in one or more flat, coplanar X-ray beams. It comprises three flat anode sheets parallel to the X-ray beam, a plurality of rod-like cathodes between the anodes, a detector gas between the electrodes and a means for applying a potential between the electrodes. Each of the X-ray sources is collimated to give a narrow, planar section of X-ray photons. Sets of X-ray sources in the array are pulsed simultaneously to obtain X-ray transmission data for tomographic image reconstruction. (U.K.)

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... changes seen in metabolic conditions. assist in the detection and diagnosis of bone cancer . locate foreign objects ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... up in shades of gray and air appears black. Until recently, x-ray images were maintained on ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg (shin), ankle or foot. top of page ... the patient standing upright, as in cases of knee x-rays. A portable x-ray machine is ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... conditions. Imaging with x-rays involves exposing a part of the body to a small dose of ... body. Once it is carefully aimed at the part of the body being examined, an x-ray ...

  12. Comparison of the dose surface product in patients with X-ray contrast examinations of the stomach with intermittent and continuous radiographic methods

    International Nuclear Information System (INIS)

    Porzel, C.

    1975-01-01

    After commenting on the proplems of radiation exposure during X-raying and a brief survey of the development of image storage systems, the author explains the pulsed storage system used for X-raying the stomach instead of conventional X-raying. Applying the intermittent X-raying method, the exposure dose could be reduced by 75%, especially in patients with a strong abdominal girth. Advantages and disadvantages and possible ways to use the method for angiography, angiocardiography and X-raying in connection with bone operations are discussed. (ORU) [de

  13. X-Ray Exam: Hip

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: Hip What's in this article? What It Is Why ... You Have Questions Print What It Is A hip X-ray is a safe and painless test ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... X-rays are a form of radiation like light or radio waves. X-rays pass through most objects, including the body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-rays. top of page What does the equipment look like? The equipment typically used for bone x-rays consists of ... and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely available in emergency ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... The x-ray tube is connected to a flexible arm that is extended over the patient while an x-ray film holder or image recording plate is placed beneath the patient. top of page How does the procedure work? X-rays are a form of radiation like ...

  17. X-Ray Exam: Ankle

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Ankle KidsHealth / For Parents / X-Ray Exam: Ankle What's in this article? What It Is Why ... You Have Questions Print What It Is An ankle X-ray is a safe and painless test ...

  18. Physical-Chemical and Mechanical characterization of some cement products in Madagascar by using Technical Analysis X-ray Fluorescence and tests receptions

    International Nuclear Information System (INIS)

    Rasolondraibe, I.P.

    2014-01-01

    The present work is completely realized at the 'Institut National des Sciences et Techniques Nucleaires (INSTN - Madagascar)' and 'Laboratoire National des Travaux Publics et du Batiment (LNTPB)'. Its purpose is to carry out the physico - chemical and mechanical analysis of the cements products present in Madagascar in order to ensure their qualities in case of Building and Publics Works construction safety. The necessary chemical elements in cements are the loss in ignition (LOI), the insoluble residues (RI), the silica (SiO 2 ), the lime (CaO), the alumina (Al 2 O 3 ), the iron oxide (Fe 2 O 3 ), the magnesia (MgO) and the sulfate (SO 3 ). In this work, analytical laboratory in X - Ray fluorescence department of INSTN - Madagascar using the direct excitation X - Ray fluorescence technique outline their research on lime and iron oxide while L.N.T.P.B materials laboratory can make all using test method by gravimetry and titrimetry according to EN 196 - 2. The results of INSTN - Madagascar show that the concentrations of calcium oxide and iron oxide are consistent with the concentration range provided by the laboratory materials L.N.T.P.B respectively equal to 50.00 % - 65.00 % and 1.00 % - 5.00 %. The results between the two laboratories have a - 4.76 % iron oxide maximum relative deviation and 4,77 % calcium oxide maximum relative deviation. Complementary physical and mechanical tests were performed at L.N.T.P.B materials laboratory respectively in accordance with EN 196 - 3 and EN 196 - 1. The used conventional X - ray fluorescence method fulfill the scope of application needed with good correlation less than ± 5 %. [fr

  19. Optics for coherent X-ray applications

    Energy Technology Data Exchange (ETDEWEB)

    Yabashi, Makina, E-mail: yabashi@spring8.or.jp [RIKEN SPring-8 Center, Kouto 1-1-1, Sayo, Hyogo 679-5148 (Japan); Tono, Kensuke [Japan Synchrotron Radiation Research Institute (JASRI), Kouto 1-1-1, Sayo, Hyogo 679-5198 (Japan); Mimura, Hidekazu [The University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-8656 (Japan); Matsuyama, Satoshi; Yamauchi, Kazuto [Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871 (Japan); Tanaka, Takashi; Tanaka, Hitoshi; Tamasaku, Kenji [RIKEN SPring-8 Center, Kouto 1-1-1, Sayo, Hyogo 679-5148 (Japan); Ohashi, Haruhiko; Goto, Shunji [Japan Synchrotron Radiation Research Institute (JASRI), Kouto 1-1-1, Sayo, Hyogo 679-5198 (Japan); Ishikawa, Tetsuya [RIKEN SPring-8 Center, Kouto 1-1-1, Sayo, Hyogo 679-5148 (Japan)

    2014-08-27

    Developments of optics for coherent X-ray applications and their role in diffraction-limited storage rings are described. Developments of X-ray optics for full utilization of diffraction-limited storage rings (DLSRs) are presented. The expected performance of DLSRs is introduced using the design parameters of SPring-8 II. To develop optical elements applicable to manipulation of coherent X-rays, advanced technologies on precise processing and metrology were invented. With propagation-based coherent X-rays at the 1 km beamline of SPring-8, a beryllium window fabricated with the physical-vapour-deposition method was found to have ideal speckle-free properties. The elastic emission machining method was utilized for developing reflective mirrors without distortion of the wavefronts. The method was further applied to production of diffraction-limited focusing mirrors generating the smallest spot size in the sub-10 nm regime. To enable production of ultra-intense nanobeams at DLSRs, a low-vibration cooling system for a high-heat-load monochromator and advanced diagnostic systems to characterize X-ray beam properties precisely were developed. Finally, new experimental schemes for combinative nano-analysis and spectroscopy realised with novel X-ray optics are discussed.

  20. Production, purification, crystallization and preliminary X-ray diffraction studies of the nucleoside diphosphate kinase b from Leishmania major

    International Nuclear Information System (INIS)

    Tonoli, Celisa Caldana Costa; Vieira, Plinio Salmazo; Ward, Richard John; Arni, Raghuvir Krishnaswamy; Oliveira, Arthur Henrique Cavalcante de; Murakami, Mario Tyago

    2009-01-01

    Overexpression, purification, crystallization and preliminary X-ray diffraction analysis of the nucleoside diphosphate kinase b from Leishmania major are reported. The crystals belonged to the trigonal space group P3 2 21 and diffracted to 2.18 Å resolution. Nucleoside diphosphate kinases (NDKs; EC 2.7.4.6) play an essential role in the synthesis of nucleotides from intermediates in the salvage pathway in all parasitic trypanosomatids and their structural studies will be instrumental in shedding light on the biochemical machinery involved in the parasite life cycle and host–parasite interactions. In this work, NDKb from Leishmania major was overexpressed in Escherichia coli, purified to homogeneity and crystallized using the sitting-drop vapour-diffusion method. The NDK crystal diffracted to 2.2 Å resolution and belonged to the trigonal crystal system, with unit-cell parameters a = 114.2, c = 93.9 Å. Translation-function calculations yielded an unambiguous solution in the enantiomorphic space group P3 2 21

  1. SMM x ray polychromator

    Science.gov (United States)

    Saba, J. L. R.

    1993-01-01

    The objective of the X-ray Polychromator (XRP) experiment was to study the physical properties of solar flare plasma and its relation to the parent active region to understand better the flare mechanism and related solar activity. Observations were made to determine the temperature, density, and dynamic structure of the pre-flare and flare plasma as a function of wavelength, space and time, the extent to which the flare plasma departs from thermal equilibrium, and the variation of this departure with time. The experiment also determines the temperature and density structure of active regions and flare-induced changes in the regions.

  2. Obstetric X-rays

    International Nuclear Information System (INIS)

    Mwachi, M.K.

    2006-01-01

    Radiography of the pelvis should never be taken to diagnose early pregnancy, because of potential hazards of radiation damage to the growing foetus. the only indication occurs in the last week of pregnancy (37 weeks). Obstetric X-ray will help you answer like confirmation of malposition,multiple pregnancies; fetal abnormalities e.g. hydrocephalus, foetal disposition. The choice of radiographic projection will help give foetal presentation, disposition as well as foetal maturity. The search pattern helps you determine maternal and spine deformity, foetal spine and head , foetal presentation and any other anomalies

  3. X-ray film

    International Nuclear Information System (INIS)

    Arndt, U.W.; Gilmore, D.J.; Wonacott, A.J.

    1977-01-01

    The performance of film as an X-ray detector is discussed and its behaviour is compared with that of a perfect Poissonian detector. The efficiency of microdensitometry as a method of extracting the information recorded on the film is discussed. More emphasis is placed in the precision of microdensitometric measurements than on the more obvious characteristic of film speed. The effects of chemical fog and background on the precision of the measurements is considered and it is concluded that the final limit to precision is set by the chemical fog. (B.D.)

  4. X-ray diffraction

    International Nuclear Information System (INIS)

    Vries, J.L. de.

    1976-01-01

    The seventh edition of Philips' Review of literature on X-ray diffraction begins with a list of conference proceedings on the subject, organised by the Philips' organisation at regular intervals in various European countries. This is followed by a list of bulletins. The bibliography is divided according to the equipment (cameras, diffractometers, monochromators) and its applications. The applications are subdivided into sections for high/low temperature and pressure, effects due to the equipment, small angle scattering and a part for stress, texture and phase analyses of metals and quantitative analysis of minerals

  5. Proceedings of the workshop on X-ray computed microtomography

    International Nuclear Information System (INIS)

    1998-02-01

    This report consists of vugraphs from the nine presentations at the conference. Titles of the presentations are: CMT: Applications and Techniques; Computer Microtomography Using X-rays from Third Generation Synchrotron X-ray; Approaches to Soft-X-ray Nanotomography; Diffraction Enhanced Tomography; X-ray Computed Microtomography Applications at the NSLS; XCMT Applications in Forestry and Forest Products; 3DMA: Investigating Three Dimensional Pore Geometry from High Resolution Images; X-ray Computed Microtomography Studies of Volcanic Rock; and 3-D Visualization of Tomographic Volumes

  6. Proceedings of the workshop on X-ray computed microtomography

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    This report consists of vugraphs from the nine presentations at the conference. Titles of the presentations are: CMT: Applications and Techniques; Computer Microtomography Using X-rays from Third Generation Synchrotron X-ray; Approaches to Soft-X-ray Nanotomography; Diffraction Enhanced Tomography; X-ray Computed Microtomography Applications at the NSLS; XCMT Applications in Forestry and Forest Products; 3DMA: Investigating Three Dimensional Pore Geometry from High Resolution Images; X-ray Computed Microtomography Studies of Volcanic Rock; and 3-D Visualization of Tomographic Volumes.

  7. Soft x-ray lasers

    International Nuclear Information System (INIS)

    Matthews, D.L.; Rosen, M.D.

    1988-01-01

    One of the elusive dreams of laser physicists has been the development of an x-ray laser. After 25 years of waiting, the x-ray laser has at last entered the scientific scene, although those now in operation are still laboratory prototypes. They produce soft x rays down to about five nanometers. X-ray lasers retain the usual characteristics of their optical counterparts: a very tight beam, spatial and temporal coherence, and extreme brightness. Present x-ray lasers are nearly 100 times brighter that the next most powerful x-ray source in the world: the electron synchrotron. Although Lawrence Livermore National Laboratory (LLNL) is widely known for its hard-x-ray laser program which has potential applications in the Strategic Defense Initiative, the soft x-ray lasers have no direct military applications. These lasers, and the scientific tools that result from their development, may one day have a place in the design and diagnosis of both laser fusion and hard x-ray lasers. The soft x-ray lasers now in operation at the LLNL have shown great promise but are still in the primitive state. Once x-ray lasers become reliable, efficient, and economical, they will have several important applications. Chief among them might be the creation of holograms of microscopic biological structures too small to be investigated with visible light. 5 figs

  8. X-ray spectrometry

    International Nuclear Information System (INIS)

    Markowicz, A.A.; Van Grieken, R.E.

    1986-01-01

    In the period under review, i.e, through 1984 and 1985, some 600 articles on XRS (X-ray spectrometry) were published; most of these have been scanned and the most fundamental ones are discussed. All references will refer to English-language articles, unless states otherwise. Also general books have appeared on quantitative EPXMA (electron-probe X-ray microanalysis) and analytical electron microscopy (AEM) as well as an extensive review on the application of XRS to trace analysis of environmental samples. In the period under review no radically new developments have been seen in XRS. However, significant improvements have been made. Gain in intensities has been achieved by more efficient excitation, higher reflectivity of dispersing media, and better geometry. Better understanding of the physical process of photon- and electron-specimen interactions led to complex but more accurate equations for correction of various interelement effects. Extensive use of micro- and minicomputers now enables fully automatic operation, including qualitative analysis. However, sample preparation and presentation still put a limit to further progress. Although some authors find XRS in the phase of stabilization or even stagnation, further gradual developments are expected, particularly toward more dedicated equipment, advanced automation, and image analysis systems. Ways are outlined in which XRS has been improved in the 2 last years by excitation, detection, instrumental, methodological, and theoretical advances. 340 references

  9. Implementation of the method air-kerma product area in KAP camera calibration with reference qualities of X-ray series at the SSDL RQR of Mexico

    International Nuclear Information System (INIS)

    Cejudo, Jesus; Tovar, Victor M.

    2013-01-01

    The X-Ray machines, at a reference laboratory for the instrument calibration in diagnostic radiology, should compliance with the ISO requirements. Sometimes there is not available as much laboratories as needed in Latin American countries. So this project shows the KAP ionization chamber implementation method using the TRS-457 radiation quality from the IAEA at the SSDL of Mexico. The KAP instruments calibration method consists in doing a substitution comparison using a standard reference with traceability to a primary laboratory and a transmission-monitoring chamber that measures the number of photons of the X-ray primary beam. A KAP chamber calibration requires a special array that consists in collocating the chamber in two different positions of its calibration process. Then, with air kerma-area product coefficient together with a corrected electrometer measure at referential conditions, the patient dosimetry magnitudes are calculated. The dosimetry necessity at hospitals always will be in function of possessing a highly reliable calibration coefficient chamber for making these measures. That dosimetry results will help in reducing the total or partial irradiation emitted to the human body of the patient. This is how stochastic risks will be lessened due to diagnostic studies. The purpose of this project is to have a synergy with calibration for making known that the SSDL of Mexico has the technical capacity to act as a link between primary standard dosimetry laboratories and the ionizing radiation equipment users who require that their KAP chamber have traceability from the primary standard to the user. (author)

  10. Proton induced L{sub 1}, L{sub 2}, L{sub 3}-sub-shell X-ray production cross sections of Hf and Au

    Energy Technology Data Exchange (ETDEWEB)

    Bertol, A.P.L., E-mail: anapaula.bertol@gmail.com [Programa de Pós-graduação em Física, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Hinrichs, R. [Programa de Pós-graduação em Física, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Instituto de Geociências, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Vasconcellos, M.A.Z. [Programa de Pós-graduação em Física, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Instituto de Física, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil)

    2015-11-15

    Experimental data for proton induced X-ray production cross sections of L-sub-shells of Hf and Au were obtained, in order to contribute to the existing data sets and to support refinements of the ECPSSR theory. X-ray emissions of mono-elemental 10 nm films of Hf and Au were excited with 0.7–1.5 MeV protons. The measured L-line spectra were fitted assuming Gaussian shapes and constraining peak positions and line widths. The transition energy values used to establish peak positions were based on values proposed in the literature, while the line widths were matched to the detector resolution, obtained independently. The intensity of each line was obtained from the adjusted areas, without the use of emission rates. The line intensities were summed in α, β, γ, and ℓ groups to validate the measurements by comparison with existing data, and in L{sub 1}, L{sub 2}, L{sub 3}-sub-shells for comparison with ECPSSR-UA theory. Ratios of the emission rates of lines of the same sub-shell were obtained and compared with the data from the literature.

  11. Quantitative X-ray measurements of high-pressure fuel sprays from a production heavy duty diesel injector

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, A.I.; Som, S.; Aggarwal, Suresh K. [University of Illinois at Chicago, Department of Mechanical and Industrial Engineering, Chicago, IL (United States); Kastengren, A.L.; El-Hannouny, E.M.; Longman, D.E.; Powell, C.F. [Argonne National Laboratory, Energy Systems Division, Argonne, IL (United States)

    2009-07-15

    A quantitative and time-resolved X-ray radiography technique has been used for detailed measurements of high-pressure fuel sprays in the near-nozzle region of a diesel engine injector. The technique provides high spatial and temporal resolution, especially in the relatively dense core region. A single spray plume from a hydraulically actuated electronically controlled unit injector model 315B injector with a 6-hole nozzle was isolated and studied at engine-like densities for two different injection pressures. Optical spray imaging was also employed to evaluate the effectiveness of the shield used to isolate a single spray plume. The steady state fuel distributions for both injection pressures are similar and show a dense spray region along the axis of the spray, with the on-axis spray density decreasing as the spray progresses downstream. The higher injection pressure case exhibits a larger cone angle and spray broadening at the exit of the nozzle. For some time periods, the near-nozzle penetration speed is lower for the high injection pressure case than the low injection pressure case, which is unexpected, but can be attributed to the needle and flow dynamics inside the injector causing slower pressure build-up for the former case. Rate of injection testing was performed to further understand near-nozzle behavior. Mass distribution data were obtained and used to find mass-averaged velocity of the spray. Comparisons of the radiography data with that from a common rail single-hole light duty injectors under similar injection conditions show several significant differences. The current data show a larger cone angle and lower penetration speed than that from the light-duty injector. Moreover, these data display a Gaussian mass distribution across the spray near the injector, whereas in previous light-duty injector measurements, the mass distribution had steeper sides and a flatter peak. Measurements are also used to examine the spray models in the STAR-CD software

  12. Quantitative X-ray measurements of high-pressure fuel sprays from a production heavy duty diesel injector

    Science.gov (United States)

    Ramírez, A. I.; Som, S.; Aggarwal, Suresh K.; Kastengren, A. L.; El-Hannouny, E. M.; Longman, D. E.; Powell, C. F.

    2009-07-01

    A quantitative and time-resolved X-ray radiography technique has been used for detailed measurements of high-pressure fuel sprays in the near-nozzle region of a diesel engine injector. The technique provides high spatial and temporal resolution, especially in the relatively dense core region. A single spray plume from a hydraulically actuated electronically controlled unit injector model 315B injector with a 6-hole nozzle was isolated and studied at engine-like densities for two different injection pressures. Optical spray imaging was also employed to evaluate the effectiveness of the shield used to isolate a single spray plume. The steady state fuel distributions for both injection pressures are similar and show a dense spray region along the axis of the spray, with the on-axis spray density decreasing as the spray progresses downstream. The higher injection pressure case exhibits a larger cone angle and spray broadening at the exit of the nozzle. For some time periods, the near-nozzle penetration speed is lower for the high injection pressure case than the low injection pressure case, which is unexpected, but can be attributed to the needle and flow dynamics inside the injector causing slower pressure build-up for the former case. Rate of injection testing was performed to further understand near-nozzle behavior. Mass distribution data were obtained and used to find mass-averaged velocity of the spray. Comparisons of the radiography data with that from a common rail single-hole light duty injectors under similar injection conditions show several significant differences. The current data show a larger cone angle and lower penetration speed than that from the light-duty injector. Moreover, these data display a Gaussian mass distribution across the spray near the injector, whereas in previous light-duty injector measurements, the mass distribution had steeper sides and a flatter peak. Measurements are also used to examine the spray models in the STAR-CD software.

  13. Do we need X-rays?

    International Nuclear Information System (INIS)

    Sadat, Theo

    2004-01-01

    Do we need X-rays? The answer depends on the cost for 25 kGy sterilization, and the cost for 10 kGy decontamination, compared with the costs of other technologies. In the past, the cost of X-ray was compared with that of Cobalt 60, because treatment by pallet was virtually obsessional. It was considered easier to treat in a Contract Service Center even though several Contract Service Centers equipped with 10 MeV high-power accelerators are in operation, and are profitable. Currently small and reliable accelerators are available, which can be inserted into a production line, i.e. instead of treating a product in its shipment carton or on a pallet, the product can be treated as a unit on the production line. In this case there is no need for extra transport, or intermediate storage facilities, and the product is 'just in time'. So we should compare the cost of treatment, taking all these parameters into account (transport, storage, time lapse, etc.) to find out if X-ray treatment could be competitive. The few studies carried out in the past compared X-ray with Cobalt 60, and the economic result was always in favour of Cobalt due to the poor conversion output. This is still valid today, even if we consider very high-power electron beam accelerators. The performance and cost of e-beam in-line, gamma ray and X-ray will be compared

  14. Studies and developments for the analysis of products of nuclear reprocessing plants with the help of the X-ray fluorescence analysis on totally reflecting sample holders (TXRF)

    International Nuclear Information System (INIS)

    Diercks, H.; Eggers, I.; Gibau, F.; Haarich, M.; Hastenteufel, S.; Haurand, M.; Knoechel, A.; Salow, H.

    1990-01-01

    Studies with inactive and active simulates of products of nuclear reprocessing plants show the suitability of the X-Ray Fluorescence Analysis on Totally Reflecting Sample Holders (TXRF), to detect the available elements simultaneously by direct measurements of specially prepared thin samples. High dilution enables in the most cases, to avoid working in hot cells and to carry out the analysis in glove boxes. The analysis of uranium products and great amounts of matrix elements containing solutions like LAW and MAW demands the separation of the matrix elements before TXRF measurement. Procedures for this task have been developed. The potential of the new analytical procedure was demonstrated by the analysis of two samples of highly diluted high active wastes. (orig.) With 65 refs., 20 tabs., 81 figs [de

  15. X-ray table

    International Nuclear Information System (INIS)

    Craig, J.R.; Otto, G.W.

    1980-01-01

    An X-ray radiographic or fluoroscopic table is described which includes a film holder with a frame attached to a cable running over end pulleys for positioning the holder longitudinally as desired under the table top. The holder has a front opening to receive a cassette-supporting tray which can be slid out on tracks to change the cassette. A reed switch on the frame is opened by a permanent magnet on the tray only when the tray is half-way out. When the switch is closed, an electromagnet locks the pulley and the holder in place. The holder is thus automatically locked in place not only during exposure (tray in) but when the tray is out for changing the cassette. To re-position the holder, the operator pulls the tray half-out and, using the tray itself, pushes the holder along the table, the holder being counterbalanced by a weight. (author)

  16. X-ray equipment

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1988-01-01

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.)

  17. X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.G.B.

    1988-01-06

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.).

  18. Accelerator X-ray sources

    International Nuclear Information System (INIS)

    Talman, R.

    2006-01-01

    This is the first monograph to cover in-depth the production of brilliant x-ray beams in accelerators, with emphasis on fourth generation designs, such as energy recovery linacs (ERL), fast cycling storage rings, and free electron lasers (FEL). Going beyond existing treatments of the influence of synchroton radiation on accelerator operation, special emphasis is placed on the design of undulator-based beam lines, and the physics of undulator radiation. Starting from the unified treatment of electron and photon beams both as bunches of particles and as waves, the author proceeds to analyse the main components, from electron gun, through linac and arc lattice, to the x-ray beam line. Designs are given for both an ERL and a more conventional storage ring complex, and their anticipated properties are compared in detail. Space charge effects are analysed with emphasis on coherent synchrotron radiation and emittance dilution. Beam diagnostics using synchrotron radiation or laser wire (Compton scattering) are also analysed in detail. Written primarily for general, particle, and radiation physicists, the systematic treatment adopted by the work makes it equally suitable as an advanced textbook for young researchers. (orig.)

  19. Effect of Electric Voltage and Current of X-ray Chamber on the Element inthe Zirconium Alloy Analysis X-ray by X-ray Fluorescence

    International Nuclear Information System (INIS)

    Yusuf-Nampira; Narko-Wibowo, L; Rosika-Krisnawati; Nudia-Barenzani

    2000-01-01

    The using of x-ray fluorescence in the chemical analysis depend heavilyon the parameters of x-ray chamber, for examples : electric voltage andelectric current. That parameter give effect in the result of determine ofSn, Cr, Fe and Ni in the zirconium alloy. 20 kV electric voltages are used onthe Mo x-ray chamber shall product x-ray of zirconium in the sample materialcan give effect in the stability of the analysis result (deviation more than5%). The result of analysis of elements in the zirconium alloy shall givedeviation less than 5% when using of electric voltage of the x-ray chamberless than 19 kV. The sensitivity of analysis can be reached by step upelectric current of x-ray chamber. (author)

  20. Development of Total Reflection X-ray fluorescence spectrometry quantitative methodologies for elemental characterization of building materials and their degradation products

    Science.gov (United States)

    García-Florentino, Cristina; Maguregui, Maite; Marguí, Eva; Torrent, Laura; Queralt, Ignasi; Madariaga, Juan Manuel

    2018-05-01

    In this work, a Total Reflection X-ray fluorescence (TXRF) spectrometry based quantitative methodology for elemental characterization of liquid extracts and solids belonging to old building materials and their degradation products from a building of the beginning of 20th century with a high historic cultural value in Getxo, (Basque Country, North of Spain) is proposed. This quantification strategy can be considered a faster methodology comparing to traditional Energy or Wavelength Dispersive X-ray fluorescence (ED-XRF and WD-XRF) spectrometry based methodologies or other techniques such as Inductively Coupled Plasma Mass Spectrometry (ICP-MS). In particular, two kinds of liquid extracts were analysed: (i) water soluble extracts from different mortars and (ii) acid extracts from mortars, black crusts, and calcium carbonate formations. In order to try to avoid the acid extraction step of the materials and their degradation products, it was also studied the TXRF direct measurement of the powdered solid suspensions in water. With this aim, different parameters such as the deposition volume and the measuring time were studied for each kind of samples. Depending on the quantified element, the limits of detection achieved with the TXRF quantitative methodologies for liquid extracts and solids were set around 0.01-1.2 and 2-200 mg/L respectively. The quantification of K, Ca, Ti, Mn, Fe, Zn, Rb, Sr, Sn and Pb in the liquid extracts was proved to be a faster alternative to other more classic quantification techniques (i.e. ICP-MS), accurate enough to obtain information about the composition of the acidic soluble part of the materials and their degradation products. Regarding the solid samples measured as suspensions, it was quite difficult to obtain stable and repetitive suspensions affecting in this way the accuracy of the results. To cope with this problem, correction factors based on the quantitative results obtained using ED-XRF were calculated to improve the accuracy of

  1. X-Ray Lasers 2016

    CERN Document Server

    Bulanov, Sergei; Daido, Hiroyuki; Kato, Yoshiaki

    2018-01-01

    These proceedings comprise a selection of invited and contributed papers presented at the 15th International Conference on X-Ray Lasers (ICXRL 2016), held at the Nara Kasugano International Forum, Japan, from May 22 to 27, 2016. This conference was part of an ongoing series dedicated to recent developments in the science and technology of x-ray lasers and other coherent x-ray sources with additional focus on supporting technologies, instrumentation and applications.   The book showcases recent advances in the generation of intense, coherent x-rays, the development of practical devices and their applications across a wide variety of fields. It also discusses emerging topics such as plasma-based x-ray lasers, 4th generation accelerator-based sources and higher harmonic generations, as well as other x-ray generation schemes.

  2. X-ray instrumentation in astronomy

    International Nuclear Information System (INIS)

    Cuhlane, J.L.

    1985-01-01

    This book presents the proceedings of a conference devoted to x-ray instrumentation in astronomy. Special sections are: AXAF X-Ray Optical Systems; Specialized X-Ray Systems; X-Ray Optical Systems I; X-Ray Optical Systems II; Gas Filled X-Ray Detectors II; The NASA Advanced X-Ray Astrophysics Facility; X-Ray and EUV Spectrometers; Microchannel Plates; and Solid State Detectors

  3. L X-ray emission induced by heavy ions

    Energy Technology Data Exchange (ETDEWEB)

    Pajek, M. [Institute of Physics, Jan Kochanowski University, 25-406 Kielce (Poland); Banaś, D., E-mail: d.banas@ujk.edu.pl [Institute of Physics, Jan Kochanowski University, 25-406 Kielce (Poland); Braziewicz, J.; Majewska, U.; Semaniak, J. [Institute of Physics, Jan Kochanowski University, 25-406 Kielce (Poland); Fijał-Kirejczyk, I. [The Institute of Atomic Energy, 05-400 Otwock-Świerk (Poland); Jaskóła, M.; Czarnacki, W.; Korman, A. [The National Centre for Nuclear Research, 05-400 Otwock-Świerk (Poland); Kretschmer, W. [Physikalisches Institut, Universität Erlangen-Nürnberg, D-91058 Erlangen (Germany); Mukoyama, T. [Institute for Nuclear Research, Hungarian Academy of Sciences (ATOMKI), H-4026 Debrecen (Hungary); Trautmann, D. [Institut für Physik, Universität Basel, Basel (Switzerland)

    2015-11-15

    Particle-induced X-ray emission (PIXE) technique is usually applied using typically 1 MeV to 3 MeV protons or helium ions, for which the ion-atom interaction is dominated by the single ionization process. For heavier ions the multiple ionization plays an increasingly important role and this process can influence substantially both the X-ray spectra and atomic decay rates. Additionally, the subshell coupling effects are important for the L- and M-shells ionized by heavy ions. Here we discuss the main features of the X-ray emission induced by heavy ions which are important for PIXE applications, namely, the effects of X-ray line shifts and broadening, vacancy rearrangement and change of the fluorescence and Coster–Kronig yields in multiple ionized atoms. These effects are illustrated here by the results of the measurements of L X-ray emission from heavy atoms bombarded by 6 MeV to 36 MeV Si ions, which were reported earlier. The strong L-subshell coupling effects are observed, in particular L{sub 2}-subshell, which can be accounted for within the coupling subshell model (CSM) developed within the semiclassical approximation. Finally, the prospects to use heavy ions in PIXE analysis are discussed.

  4. Total L-shell X-ray production cross sections by 400-700 keV proton impact for elements with 34≤Z≤53

    International Nuclear Information System (INIS)

    Miranda, J.; Ledesma, R.; Lucio, O.G. de

    2001-01-01

    Total L-shell X-ray production cross sections induced by protons with energies between 400 and 700 keV were measured for elements with atomic number Z between 34 and 53. The ECPSSR theory describes appropriately the results. This model modifies the plane wave born approximation by considering projectile energy loss (E), Coulomb deflection of the incoming ion (C), polarization and change in electron binding energies through a perturbed stationary states method (PSS) and relativistic values of target electron mass (R). A comparison is given with previously published data for proton energies below 1 MeV and 26 ≤ Z ≤ 53, based on a scaling obtained from a reduced velocity parameter ξ L R . The results show that the scaling for these atomic numbers and energy ranges is adequate and a semi-empirical expression to calculate those cross sections is proposed

  5. Measurements of Lα, Lβ x-ray production cross sections of Pb by 16-40 keV electron impact

    International Nuclear Information System (INIS)

    Wu, Y; An, Z; Duan, Y M; Liu, M T; Tang, C H

    2007-01-01

    The measurement of L α , L β x-ray production cross sections for the element Pb (Z = 82) by 16-40 keV electron impact is reported in this paper. The target used in the experiment was prepared by evaporating the elemental Pb onto a thick pure carbon substrate. The effects of multiple scattering of electrons when penetrating the target film, of electrons reflected from the thick pure carbon substrate and of bremsstrahlung photons produced by the impact of incident electrons on the target are corrected using the Monte Carlo method. The experimental data, reported here for the first time in the energy region of interest, are compared with the plane-wave Born approximation theory with exchange, Coulomb and relativistic corrections. They are in good agreement

  6. Measurements of Lα, Lβ X-ray production cross sections of Bi by 17-40 keV electron impact

    International Nuclear Information System (INIS)

    Wu, Y.; An, Z.; Duan, Y.M.; Liu, M.T.

    2010-01-01

    We present results of measurements of L α , L β X-ray production cross sections for the element Bi (Z = 83) by 17-40 keV electron impact. The target used in the experiment was prepared by evaporating the element Bi to the thick pure carbon substrate. The effects of multiple scattering of electrons when penetrating the target film, of electrons reflected from the thick pure carbon substrate and of bremsstrahlung photons produced by the impact of incident electrons on the target are corrected by means of Monte Carlo simulation. The experimental data, reported here for the first time in the energy region of 17-40 keV, are compared with the DWBA theory and the PWBA-C-Ex theory. They are in good agreement.

  7. Topological X-Rays Revisited

    Science.gov (United States)

    Lynch, Mark

    2012-01-01

    We continue our study of topological X-rays begun in Lynch ["Topological X-rays and MRI's," iJMEST 33(3) (2002), pp. 389-392]. We modify our definition of a topological magnetic resonance imaging and give an affirmative answer to the question posed there: Can we identify a closed set in a box by defining X-rays to probe the interior and without…

  8. Fission products determination in high activity waste solution by wavelength dispersive X-ray fluorescence spectral interference correction by intensity ratio

    International Nuclear Information System (INIS)

    Sato, I.M.

    1988-01-01

    Fission products Se, Rb, Y, Zr, Mo, Ru, Rh, Pd, Te, Cd, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu and Gd were determined in simulated high activity radioactive waste solution by wavelength dispersive X-ray fluorescence spectrometry without chemical separation. Thin layer technique was employed for the sample preparation. For the L spectral lines, the absorption effect was verified by Rasberry-Heinrich, Lucas Tooth-Pyne and Lachance-Trail relations. This effect was quantified and corrected accordingly. The spectral interferences of Kα and/or Lα lines of Y, Zr, Mo, La, Ce, Pr, Nd, Sm, Eu and Gd elements were eliminated by the intensity ratio method. The overlapping of up to three analytical lines was corrected by applying this method. The concentration influence of the interfering element on the intensity ratio values as well the efficiency of the correction method were investigated in order to assure that no systematic or residual error, resulting from the correction, affect the actual fluorescent intensity determination. The results is compared with the data obtained from measurements of free lines of spectral interference and also with those obtained by the linear equation system. Fission products determination presented a precision in the range of 0.1 to 5.0% and an accuracy of up to ± 7.0% the results are compared with those obtained by neutron activation analysis and inductively coupled plasma - atomic emission spectrometry. Leaching data, when radioactive waste is incorporated in cement matrix, were attempted by X-ray fluorescence technique. For two years leaching period, leaching rate and diffusion coefficient data of cesium were determined. The results obtained agree with those obtained by γ-spectromety. (author) [pt

  9. X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  10. X-ray filtration apparatus

    International Nuclear Information System (INIS)

    Thompson, G.

    1992-01-01

    This invention relates to an X-ray shielding support device. In spite of considerable development in X-ray taking techniques, a need still exists for effective shielding, inter alia, to compensate for variations in the thickness, density and the absorption properties of the object being studied. By appropriate shielding, the X-ray image produced is of sufficient detail, contrast and intensity over its entire area to constitute a useful diagnostic aid. It is also desirable to subject the patient to the smallest possible X-ray dosage. 4 figs

  11. Study of a high finesse four mirrors Fabry Perot cavity for X-rays and Gamma rays production by laser-electron Compton scattering

    International Nuclear Information System (INIS)

    Fedala, Y.

    2008-10-01

    The main goal of this thesis is the study and design of a high finesse Fabry Perot cavity to amplify a laser beam in order to achieve power gains ranging from 10 4 to 10 5 . This cavity is dedicated to the production of intense and monochromatic X-ray for medical applications (medical RADIOTHOMX ring) and gamma rays for a Compton based polarized positron source by Compton scattering of a high power laser beam and electron beam. To increase the brightness of the Compton interaction at the collision points, it is essential to have not only a high power laser beam but also very small laser beam radii at the interaction points. To achieve such performances, 2 scenarios are possible: a concentric 2 mirrors cavity which is mechanically unstable or a 4 mirrors cavity more complex but more stable. We tested numerically mechanical stability and stability of Eigen modes polarization of various planar and non-planar geometries of 4 mirrors cavities. Experimentally, we have developed a four mirrors tetrahedral 'bow-tie' cavity; radii of the order of 20 microns were made. The Eigen modes of such a cavity, in both planar and non planar geometries, were measured and compared with the numerical results. A good agreement was observed. In a second time, the impact of Compton interaction on the transverse dynamics, in the case of the polarized positrons source, and the longitudinal dynamic, in the case of the medical ring of the electron beam was studied. Compton scattering causes energy loss and induces an additional dispersion of energy in electron beam. For the polarized positrons source, 10 collision points are planned. The transport line has been determined and the modelling of the Compton interaction effect with a simple matrix calculation was made. For the medical ring, Compton scattering causes bunch lengthening and the increase of energy dispersion which are to influence the produced X-ray flux. A study of the longitudinal dynamics of the electron beam in the ring was

  12. X-ray emission spectroscopy. X-ray fluorescence

    International Nuclear Information System (INIS)

    Despujols, J.

    1992-01-01

    Principles of X-ray emission spectrometry are first recalled, then wave-length dispersive and energy dispersive X-ray fluorescence spectrometer are described. They are essentially designed for qualitative and quantitative analysis of elements (Z>10). Sample preparation, calibration, corrections, interferences, accuracy are reviewed. Examples of use in different industries are given. (71 refs.)

  13. Experimental study of mechanisms of sand production using X-ray computerized tomography; Estudo experimental dos mecanismos da producao de areia empregando tomografia computadorizada de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Janaina B.; Vargas Junior, Euripedes [Pontificia Univ. Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. de Engenharia Civil; Barroso, Emilio V. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Geologia; Campos, Elisabete; Goncalves, Clemente; Tavares, Andre [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES)

    2004-07-01

    During productive phase of the well, many times there is simultaneous production of the solid particles detached from matrix of the reservoir rock. This phenomenon receives the name of the sand production. In this case stress and flow conditions around of the well are fundamental factors for deflagration of the process. Stress concentration in the wall of the well lead to the loss of cohesion between grains arising, consequently, a granular material region susceptible for dragging by seepage forces derived from fluid flow. The objective of this work was to perform sand production tests in Rio Bonito and synthetic sandstone samples using real-time X-Ray Computerized Tomography. The tests investigated the initial and the evolution of failure at the cavity wall of samples. These are initial stages of the sand production process. The analysis of the CT-scans obtained during tests allowed the visualization of breakouts and collapses of the wells. From studies more details were possible estimate the sand production and produce 3-D images of the propagation of the failure. (author)

  14. Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production.

    Science.gov (United States)

    Leung, Michael K K; Chow, James C L; Chithrani, B Devika; Lee, Martin J G; Oms, Barbara; Jaffray, David A

    2011-02-01

    The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. The effective range, deflection angle, dose deposition, energy, and interaction processes of electrons produced from the interaction of x-rays with a GNP were calculated by Monte Carlo simulations. The GEANT4 code was used to simulate and track electrons generated from a 2, 50, and 100 nm diameter GNP when it is irradiated with a 50 kVp, 250 kVp, cobalt-60, and 6 MV photon beam in water. When a GNP was present, depending on the beam energies used, secondary electron production was increased by 10- to 2000-fold compared to an absence of a GNP. Low-energy photon beams were much more efficient at interacting with the GNP by two to three orders of magnitude compared to MV energies and increased the deflection angle. GNPs with larger diameters also contributed more dose. The majority of the energy deposition was outside the GNP, rather than self-absorbed by the nanoparticle. The mean effective range of electron tracks for the beams tested ranged from approximately 3 microm to 1 mm. These simulated results yield important insights concerning the spatial distributions and elevated dose in GNP-enhanced radiotherapy. The authors conclude that the irradiation of GNP at lower photon energies will be more efficient for cell killing. This conclusion is consistent with published studies.

  15. X-ray Production by Cascading Stages of a High-Gain Harmonic Generation Free-Electron Laser II: Special Topics

    Energy Technology Data Exchange (ETDEWEB)

    Wu, J

    2004-09-01

    In this paper, we study the tolerance of a new approach to produce coherent x-ray by cascading several stages of a High-Gain Harmonic Generation (HGHG) Free-Electron Laser (FEL). Being a harmonic generation process, a small noise in the initial fundamental signal will lead to a significant noise-to-signal (NTS) ratio in the final harmonic, so the noise issue is studied in this paper. We study two sources of noise: the incoherent undulator radiation, which is a noise with respect to the seed laser; and the noise of the seed laser itself. In reality, the electron beam longitudinal current profile is not uniform. Since the electron beam is the amplification medium for the FEL, this non- uniformity will induce phase error in the FEL. Therefore, this effect is studied. Phase error due to the wakefield and electron beam self-field is also studied. Synchrotronization of the electron beam and the seed laser is an important issue determining the success of the HGHG. We study the timing jitter induced frequency jitter in this paper. We also show that an HGHG FEL poses a less stringent requirement on the emittance than a SASE FEL does, due to a Natural Emittance Effect Reduction (NEER) mechanism. This NEER mechanism suggests a new operation mode, i.e., the HGHG FEL could adopt a high current, though unavoidable, a high emittance electron beam. Study in this paper shows that, production of hard x-rays with good longitudinal coherence by cascading stages of a HGHG FEL is promising. However, technical improvement is demanded.

  16. X-ray irradiation of yeast cells

    Science.gov (United States)

    Masini, Alessandra; Batani, Dimitri; Previdi, Fabio; Conti, Aldo; Pisani, Francesca; Botto, Cesare; Bortolotto, Fulvia; Torsiello, Flavia; Turcu, I. C. Edmond; Allott, Ric M.; Lisi, Nicola; Milani, Marziale; Costato, Michele; Pozzi, Achille; Koenig, Michel

    1997-10-01

    Saccharomyces Cerevisiae yeast cells were irradiated using the soft X-ray laser-plasma source at Rutherford Laboratory. The aim was to produce a selective damage of enzyme metabolic activity at the wall and membrane level (responsible for fermentation) without interfering with respiration (taking place in mitochondria) and with nuclear and DNA activity. The source was calibrated by PIN diodes and X-ray spectrometers. Teflon stripes were chosen as targets for the UV laser, emitting X-rays at about 0.9 keV, characterized by a very large decay exponent in biological matter. X-ray doses to the different cell compartments were calculated following a Lambert-Bouguet-Beer law. After irradiation, the selective damage to metabolic activity at the membrane level was measured by monitoring CO2 production with pressure silicon detectors. Preliminary results gave evidence of pressure reduction for irradiated samples and non-linear response to doses. Also metabolic oscillations were evidenced in cell suspensions and it was shown that X-ray irradiation changed the oscillation frequency.

  17. X-ray photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Attekum, P.M.T.M. van.

    1979-01-01

    The methods and results of X-ray photoelectron spectroscopy in the study of plasmons, alloys and gold compounds are discussed. After a comprehensive introduction, seven papers by the author, previously published elsewhere, are reprinted and these cover a wide range of the uses of X-ray photoelectron spectroscopy. (W.D.L.)

  18. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral dental X-ray apparatus for panoramic radiography is described in detail. It comprises a tubular target carrier supporting at its distal end a target with an inclined forward face. Image definition is improved by positioning in the path of the X-rays a window of X-ray transmitting ceramic material, e.g. 90% oxide of Be, or Al, 7% Si0 2 . The target carrier forms a probe which can be positioned in the patient's mouth. X-rays are directed forwardly and laterally of the target to an X-ray film positioned externally. The probe is provided with a detachable sleeve having V-form arms of X-ray opaque material which serve to depress the tongue out of the radiation path and also shield the roof of the mouth and other regions of the head from the X-ray pattern. A cylindrical lead shield defines the X-ray beam angle. (author)

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and easiest ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. top of page What are the limitations of Bone X-ray (Radiography)? ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Arthritis X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety How to Read Your Radiology Report ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are a form of radiation like light or radio waves. X-rays pass through most objects, including the body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small burst of radiation that passes through the body, recording ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different parts of the body absorb the x-rays in ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... lowest radiation dose possible while producing the best images for ... organizations continually review and update the technique standards used ...

  6. X-ray tube current control

    International Nuclear Information System (INIS)

    Dupuis, W.A.; Resnick, T.A.

    1982-01-01

    A closed loop feedback system for controlling the current output of an x-ray tube. The system has circuitry for improving the transient response and stability of the x-ray tube current over a substantial nonlinear portion of the tube current production characteristic. The system includes a reference generator for applying adjustable step function reference signals representing desired tube currents. The system also includes means for instantaneous sensing of actual tube current. An error detector compares the value of actual and reference tube current and produces an error signal as a function of their difference. The system feedback loop includes amplification circuitry for controlling x-ray tube filament dc voltage to regulate tube current as a function of the error signal value. The system also includes compensation circuitry, between the reference generator and the amplification circuitry, to vary the loop gain of the feedback control system as a function of the reference magnitude

  7. Defects in medical X-ray equipment

    International Nuclear Information System (INIS)

    Eder, H.; Wahl, H.; Troeger, W.

    1979-01-01

    A careful estimate of the effects on the genetically significant radiation load shows that it is in the same order of magnitude as the increase in the skin dose area product. This is to say that of the genetically significant radiation dose of about 500 mJ/kg (50 mrem) per year and person due to medical X-ray diagnostics, about 75 mJ/kg (7.5 mrem) are due to serious defects in X-ray equipment. (orig.) [de

  8. Programmers for diagnostic x-ray apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Novel apparatus is described for providing a pre-programmed selection of various parameters in X-ray radiography. The equipment consists of push-buttons which prompt the radiographer to make decisions such as thickness of patient, part of the anatomy to be X-rayed etc. From these data the apparatus selects the appropriate parameters such as H.T. voltage, current, product of current and irradiation time etc. The values of these parameters are displayed to the radiographer and facilities are provided to override the programmed parameters at the radiographer's discretion. (U.K.)

  9. Calculation of characteristics of X-ray devices

    Directory of Open Access Journals (Sweden)

    Orobinskyi A. N.

    2015-12-01

    Full Text Available Actuality of this work is related to human radiation safety during tuning and regulation of X-ray devices in the process of their development and production. The more precise the calculations for the device are, the less time is required for its tuning and regulation, and thus people are less exposed to radiation. When developing an X-ray device, it is necessary to choose an X-ray tube and filters taking into account the application domain of the device. In order to do this, one should know anode voltage, X-ray tube anode current, material and thickness of filters, i.e. to calculate these characteristics at the set quality of X-ray radiation. The known published studies do not give any solution to this problem. The scientific novelty of this work is that it establishes the interdependence between main characteristics of the X-ray device: the function of the device defines the quality of X-ray radiation (mean photon energy and air kerma power; mean photon energy depends on the X-ray anode tube voltage and spectral resolution; air kerma power depends on anode tube voltage, current of X-ray tube anode, spectral resolution, thicknesses of the filters and their materials; spectral resolution depends on thicknesses of filters and their materials; thickness of filters depends on the material of the filter (the linear coefficient of weakening of X-ray radiation. Knowledge of interdependence of basic characteristics of the X-ray devices allowes developing simple algorithm for their calculation at the values of homogeneity coefficient from 0,8 to 1, which makes it possible to choose an X-ray tube and filters with the purpose of obtaining X-ray radiation of the set quality.

  10. X-ray imaging system

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    A novel, high-speed apparatus for use in X-ray computerised tomography is described in detail. It consists of a semi-circular array of X-ray sources, collimators and an ion chamber array for detection of the X-rays. The X-ray sources may be pulsed in salvos such that the corresponding detectors in the array are only illuminated by one source. The use of computer controlled salvos speeds up the image processing by at least a factor of two. The ion chamber array is designed to have a constant detection efficiency for varying angles of X-ray incidence. A detailed description of the detector construction and suggested gaseous fillings are given. It is claimed that the present tomographic system allows fast and accurate imaging of internal body organs and is insensitive to the blurring effects which motion of these organs tends to produce. (UK)

  11. X-ray diagnostics for TFTR

    International Nuclear Information System (INIS)

    von Goeler, S.; Hill, K.W.; Bitter, M.

    1982-12-01

    A short description of the x-ray diagnostic preparation for the TFTR tokamak is given. The x-ray equipment consists of the limiter x-ray monitoring system, the soft x-ray pulse-height-analysis-system, the soft x-ray imaging system and the x-ray crystal spectrometer. Particular attention is given to the radiation protection of the x-ray systems from the neutron environment

  12. X-ray filter for chest X-rays

    International Nuclear Information System (INIS)

    Ferlic, D.J.

    1984-01-01

    A description is given of an X-ray filter comprised of a sheet of radiation absorbing material with an opening corresponding to the spine and central portion of the heart. The upper portion of the filter exhibits a relatively narrow opening which becomes gradually wider toward the lower portion of the filter. This filter will permit an acceptable density level of x-ray exposure for the lungs while allowing a higher level of x-ray exposure for the mediastinum areas of the body. (author)

  13. X-ray filter for chest x-rays

    International Nuclear Information System (INIS)

    Ferlic, D.J.

    1984-01-01

    Filter for use in medical x-ray apparatus to permit higher intensity x-ray exposure in the heart and mediastinum area while maintaining a normal level of x-ray exposure in other areas of the body, particlarly in the lung area. The filter comprises a sheet of radiation absorbing material having an opening therein, said opening corresponding to the spine and central portion of the heart. Accordingly, the upper portion of the filter exhibits a relatively narrow opening which becomes gradually wider toward the lower portion of the filter

  14. Deposition and characterization of multilayers on thin foil x-ray mirrors for high-throughput x-ray telescopes

    DEFF Research Database (Denmark)

    Hussain, Ahsen M.; Joensen, Karsten D.; Hoeghoej, P.

    1996-01-01

    W/Si and Co/C multilayers have been deposited on epoxy- replicated Au mirrors from the ASTRO-E telescope project, SPectrum Roentgen Gamma (SRG) flight mirrors, DURAN glass substrates and Si witness wafers. A characterization of the multilayers with both hard x-rays and soft x-rays is presented....... This clearly indicates the effectiveness of the epoxy-replication process for the production of smooth substrates for multilayer deposition to be used in future x-ray telescopes....

  15. Synchrotron based x-ray fluorescence microscopy confirms copper in the corrosion products of metals in contact with treated wood

    Science.gov (United States)

    Samuel L. Zelinka; Joseph E. Jakes; Grant T. Kirker; David Vine; Stefan Vogt

    2017-01-01

    Copper based waterborne wood preservatives are frequently used to extend the service life of wood products when subjected to frequent moisture exposure. While these copper based treatments protect the wood from fungal decay and insect attack, they increase the corrosion of metals embedded or in contact with the treated wood. Previous research has shown the most...

  16. The impact of iodinated X-ray contrast agents on formation and toxicity of disinfection by-products in drinking water.

    Science.gov (United States)

    Jeong, Clara H; Machek, Edward J; Shakeri, Morteza; Duirk, Stephen E; Ternes, Thomas A; Richardson, Susan D; Wagner, Elizabeth D; Plewa, Michael J

    2017-08-01

    The presence of iodinated X-ray contrast media (ICM) in source waters is of high concern to public health because of their potential to generate highly toxic disinfection by-products (DBPs). The objective of this study was to determine the impact of ICM in source waters and the type of disinfectant on the overall toxicity of DBP mixtures and to determine which ICM and reaction conditions give rise to toxic by-products. Source waters collected from Akron, OH were treated with five different ICMs, including iopamidol, iopromide, iohexol, diatrizoate and iomeprol, with or without chlorine or chloramine disinfection. The reaction product mixtures were concentrated with XAD resins and the mammalian cell cytotoxicity and genotoxicity of the reaction mixture concentrates was measured. Water containing iopamidol generated an enhanced level of mammalian cell cytotoxicity and genotoxicity after disinfection. While chlorine disinfection with iopamidol resulted in the highest cytotoxicity overall, the relative iopamidol-mediated increase in toxicity was greater when chloramine was used as the disinfectant compared with chlorine. Four other ICMs (iopromide, iohexol, diatrizoate, and iomeprol) expressed some cytotoxicity over the control without any disinfection, and induced higher cytotoxicity when chlorinated. Only iohexol enhanced genotoxicity compared to the chlorinated source water. Copyright © 2017. Published by Elsevier B.V.

  17. Charge collection and absorption-limited x-ray sensitivity of pixellated x-ray detectors

    International Nuclear Information System (INIS)

    Kabir, M. Zahangir; Kasap, S.O.

    2004-01-01

    The charge collection and absorption-limited x-ray sensitivity of a direct conversion pixellated x-ray detector operating in the presence of deep trapping of charge carriers is calculated using the Shockley-Ramo theorem and the weighting potential of the individual pixel. The sensitivity of a pixellated x-ray detector is analyzed in terms of normalized parameters; (a) the normalized x-ray absorption depth (absorption depth/photoconductor thickness), (b) normalized pixel width (pixel size/thickness), and (c) normalized carrier schubwegs (schubweg/thickness). The charge collection and absorption-limited sensitivity of pixellated x-ray detectors mainly depends on the transport properties (mobility and lifetime) of the charges that move towards the pixel electrodes and the extent of dependence increases with decreasing normalized pixel width. The x-ray sensitivity of smaller pixels may be higher or lower than that of larger pixels depending on the rate of electron and hole trapping and the bias polarity. The sensitivity of pixellated detectors can be improved by ensuring that the carrier with the higher mobility-lifetime product is drifted towards the pixel electrodes

  18. A new possibility for production of sub-picosecond x-ray pulses using a time dependent radio frequency orbit deflection

    Energy Technology Data Exchange (ETDEWEB)

    Zholents, A.

    2015-10-21

    It is shown that two radio frequency deflecting cavities with slightly different frequencies can be used to produce time-dependent orbit deflection to a few special electron bunches circulating in a synchrotron without affecting the majority of the electron bunches. These special bunches produce an x-ray pulse in which transverse position or angle, or both, are correlated with time. The x-ray pulse is then shortened, either with an asymmetrically cut crystal that acts as a pulse compressor, or with an angular aperture such as a narrow slit positioned downstream. The implementation of this technique creates a highly flexible environment for synchrotrons in which users of most beamlines will be able to easily select between the x-rays originated by the standard electron bunches and the short x-ray pulses originated by the special electron bunches carrying a time-dependent transverse correlation.

  19. A New Possibility for Production of Sub-picosecond X-ray Pulses using a Time Dependent Radio Frequency Orbit Deflection

    Energy Technology Data Exchange (ETDEWEB)

    Zholents, A. A. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-05-01

    It is shown that two radio frequency deflecting cavities with slightly different frequencies can be used to produce time-dependent orbit deflection to a few special electron bunches while keeping the majority of the electron bunches unaffected. These special bunches produce an x-ray pulse in which transverse position or angle, or both, are correlated with time. The x-ray pulses are then shortened, either with an asymmetrically cut crystal that acts as a pulse compressor, or with an angular aperture such as a narrow slit positioned downstream. The implementation of this technique creates a highly flexible environment for synchrotrons in which users of most beamlines will be able to easily select between the x-rays originated by the standard electron bunches and the short x-ray pulses originated by the special electron bunches carrying a time-dependent transverse correlation.

  20. Surface characterization by X-ray photoelectron spectroscopy and cyclic voltammetry of products formed during the potentiostatic reduction of chalcopyrite

    International Nuclear Information System (INIS)

    Nava, Dora; Gonzalez, Ignacio; Leinen, Dietmar; Ramos-Barrado, Jose R.

    2008-01-01

    Surface characterization of the transient products that precede chalcocite formation during chalcopyrite reduction was carried out. The experimental strategy employed in the present work consisted of the application of different potential pulses (fixed energetic conditions) on the surface of chalcopyrite electrodes in 1.7 M H 2 SO 4 . The chemical products formed at different potential pulses were characterized by cyclic voltammetry (CV) and XPS. Each electrogenerated species presented a specific voltammetric behavior and an XPS spectrum, in which the values of principal photoelectronic peak bond energies for Cu 2p 3/2 , Fe 2p 3/2 and S 2p 3/2 and the atomic concentrations were considered. Several potential intervals could be identified: in 0.115 ≥ E cat ≥ -0.085 V vs. SHE, an intermediate copper sulfide is formed whose composition is between those of chalcopyrite and bornite, such as talnakhite. The reduction of this product occurs slowly, giving bornite at potentials less than -0.085 V. In the applied potential region -0.085 ≥ E cat > -0.185 V, the bornite gradually decomposes causing the incomplete conversion to chalcocite. In the potential interval -0.185 > E cat ≥ -0.285 V, energetic conditions are large enough to allow the immediate decomposition of bornite, forming chalcocite in a more quantitative manner

  1. Evaluation of X-ray shielding performance of protective aprons

    International Nuclear Information System (INIS)

    Kumagai, Michitomo; Shintani, Mitsuo; Kuranishi, Makoto

    1999-01-01

    Lead equivalent, which offers protection against x-rays, is rated with a 100 kV tube voltage in Japanese Industrial Standard (JIS) Z 4501-1988, Testing method of lead equivalent for x-ray protective devices.'' However, the actual tube voltage in general diagnostic examinations (normal to special radiography; including computed tomography, CT) is 50 to 150 kV. Therefore, we measured whether the performance of current lead aprons (three products) and protective aprons using composite materials (two products) changes at 60 to 141 kV of tube voltage. Furthermore, we evaluated x-ray shielding performance by measuring the transmission ratio of scattered x-rays. The lead equivalent of two currently used lead aprons was almost the same at all voltages. However, in one currently used lead apron and both protective aprons made of composite materials, lead equivalent decreased rapidly when tube voltage exceeded 100 kV. The transmission ratio of scattered x-rays increased with increasing tube voltage in all of the protective aprons examined. Further, in all aprons examined, the transmission ratio of scattered x-rays declined with widening of the scatter angle. As mentioned above, the x-ray shielding performance of some x-ray protective aprons suddenly decreased at tube voltages over 100 kV. Thus the performance of x-ray protective aprons should be published, and JIS Z 4501 needs to be revised. (author)

  2. Evaluation of X-ray shielding performance of protective aprons

    Energy Technology Data Exchange (ETDEWEB)

    Kumagai, Michitomo; Shintani, Mitsuo; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1999-04-01

    Lead equivalent, which offers protection against x-rays, is rated with a 100 kV tube voltage in Japanese Industrial Standard (JIS) Z 4501-1988, Testing method of lead equivalent for x-ray protective devices.`` However, the actual tube voltage in general diagnostic examinations (normal to special radiography; including computed tomography, CT) is 50 to 150 kV. Therefore, we measured whether the performance of current lead aprons (three products) and protective aprons using composite materials (two products) changes at 60 to 141 kV of tube voltage. Furthermore, we evaluated x-ray shielding performance by measuring the transmission ratio of scattered x-rays. The lead equivalent of two currently used lead aprons was almost the same at all voltages. However, in one currently used lead apron and both protective aprons made of composite materials, lead equivalent decreased rapidly when tube voltage exceeded 100 kV. The transmission ratio of scattered x-rays increased with increasing tube voltage in all of the protective aprons examined. Further, in all aprons examined, the transmission ratio of scattered x-rays declined with widening of the scatter angle. As mentioned above, the x-ray shielding performance of some x-ray protective aprons suddenly decreased at tube voltages over 100 kV. Thus the performance of x-ray protective aprons should be published, and JIS Z 4501 needs to be revised. (author)

  3. Semiconductor X-ray detectors

    CERN Document Server

    Lowe, Barrie Glyn

    2014-01-01

    Identifying and measuring the elemental x-rays released when materials are examined with particles (electrons, protons, alpha particles, etc.) or photons (x-rays and gamma rays) is still considered to be the primary analytical technique for routine and non-destructive materials analysis. The Lithium Drifted Silicon (Si(Li)) X-Ray Detector, with its good resolution and peak to background, pioneered this type of analysis on electron microscopes, x-ray fluorescence instruments, and radioactive source- and accelerator-based excitation systems. Although rapid progress in Silicon Drift Detectors (SDDs), Charge Coupled Devices (CCDs), and Compound Semiconductor Detectors, including renewed interest in alternative materials such as CdZnTe and diamond, has made the Si(Li) X-Ray Detector nearly obsolete, the device serves as a useful benchmark and still is used in special instances where its large, sensitive depth is essential. Semiconductor X-Ray Detectors focuses on the history and development of Si(Li) X-Ray Detect...

  4. Evaluation of absorbed dose-distribution in the X-ray or gamma-irradiator for blood products

    International Nuclear Information System (INIS)

    Moriyama, Satoshi; Kurihara, Katsuhiko; Yokokawa, Nobuhiko; Satake, Masahiro; Juji, Takeo

    2001-01-01

    Irradiation of blood products abrogates the proliferation of lymphocytes present in cellular component, which is currently the only accepted methodology to prevent transfusion-associated graft versus host disease (TA-GVHD). A range of irradiation dose levels between 15 Gy and 50 Gy is being used, but the majority of facilities are employing 15 Gy. It should, however, be recognized that the delivered dose in the instrument canister might differ from the actual dose absorbed by the blood bag. This study have evaluated the actual dose distribution under practical conditions where a container was loaded with blood products or water bags, or filled with distilled water. This approach provides data that the maximum attenuation occurred when the container was completely filled with a blood-compatible material. Thus, an error of approximately 20 percent should be considered in the dose measured in the in-air condition. A dose calibration in an in-air condition may lead to substantial underexposure of the blood products. A dose distribution study using adequately prearranged exposure period verified that the absorbed dose of 15 Gy was attained at any point in the container for both linear accelerator and gamma-irradiator. The maximal difference in the absorbed dose between measured points was 1.5- and 1.6-fold for linear accelerator and gamma-irradiator, respectively. In conclusion, using blood-compatible materials, a careful dose calibration study should be employed in which the absorbed dose of 15 Gy is obtained at the point where the lowest dose could be expected. (author)

  5. X-ray film calibration

    International Nuclear Information System (INIS)

    Stone, G.F.; Dittmore, C.H.; Henke, B.L.

    1986-01-01

    This paper discusses the use of silver halide x-ray films for imaging and spectroscopy which is limited by the range of intensities that can be recorded and densitometered. Using the manufacturers processing techniques can result in 10 2-3 range in intensity recorded over 0-5 density range. By modifying the chemistry and processing times, ranges of 10 5-6 can be recorded in the same density range. The authors report on x-ray film calibration work and dynamic range improvements. Changes to the processing chemistry and the resulting changes in dynamic range and x-ray sensitivity are discussed

  6. Women and x-rays

    Energy Technology Data Exchange (ETDEWEB)

    Dunkley, P A; Stewart, J H

    1976-01-01

    When a woman comes to an X-Ray Department it is usually necessary to know the present stage of her menstrual cycle. X-Rays may have an adverse effect on the embryo, especially in early pregnancy. However, exposure to X-Rays at any stage may be associated with a slightly increased incidence of malignant disease in childhood. The International Commission on Radiological Protection recommends that in women of child-bearing age (in some cases as young as 11 years), non-urgent diagnostic radiography be confined to the preovulatory phase of the menstrual cycle: that is, 14 days following the first day of the last menstrual period.

  7. Hard X-ray total scattering study on the structure of Si-dopped ferric oxyhydroxides and products of their transformation

    Science.gov (United States)

    Pieczara, Gabriela; Borkiewicz, Olaf; Manecki, Maciej; Rzepa, Grzegorz

    2016-04-01

    Here we report the results of a detailed structural investigation, using synchrotron-based pair distribution function analyses (PDF) and high-resolution X-ray diffraction (HR-XRD), on a series of Si-bearing synthetic analogues of ferrihydrite with a range of Si/Fe ratio relevant to geological environments and on products of their thermal transformation. Hard X-ray total scattering data suitable for PDF analyses have been collected at the PDF-dedicated beamline 11-ID-B and the HR-XRD data at beamline 11-BM of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). Ferrihydrite is a poorly crystalline, nano-sized hydrous ferric oxyhydroxide with a nominal/ideal formula Fe5HO8•4H2O. Its chemical composition however, can vary significantly and the atomic structure is yet to be fully understood despite multitude of structural studies undertaken over the past two decades (Michel et al., 2007; Manceau, 2009). One of the most commonly discussed and still unsettled contention points regarding the structural arrangements of ferrihydrite is related to the presence or absence of tetraherdally coordinated iron(III) within its structure. The majority of experimental work carried out to date focused on pure, synthetic ferrihydrite analogues with chemical composition close to ideal/nominal. This approach is clearly a significant oversimplification of natural ferrihydrite which always contains substantial amounts of admixtures, with Si, C, P, As, Ca, S and Al being the most common. One of the most important and the most commonly encountered impurities is Si, in the form of silicate ion that has strong affinity for ferrihydrite. SiO2content in natural ferrihydrites can vary substantially but generally falls with the range of 2.6-31.5 wt% (Cismasu et al., 2011). In certain environments however, such as modern seafloor hydrothermal vents, higher Si/Fe ratios (up to ca. 3) have been reported (Sun et al., 2013). The results of previous reports indicate that silicate

  8. Upsurge of X-ray astronomy 230-

    International Nuclear Information System (INIS)

    Hudec, D.R.

    1978-01-01

    Instruments are described used for X-ray astronomy, namely X-ray detectors and X-ray telescopes. Unlike telescopes, the detectors do not comprise X-ray optics. A survey is given of the results obtained in solar and stellar X-ray astronomy and hypotheses are submitted on the origin of X radiation in the interstellar space. (J.B.)

  9. Medical X-ray sources now and for the future

    Science.gov (United States)

    Behling, Rolf

    2017-11-01

    This paper focuses on the use of X-rays in their largest field of application: medical diagnostic imaging and image-guided therapy. For this purpose, vacuum electronics in the form of X-ray tubes as the source of bremsstrahlung (braking radiation) have been the number one choice for X-ray production in the range of photon energies between about 16 keV for mammography and 150 keV for general radiography. Soft tissue on one end and bony structures on the other are sufficiently transparent and the contrast delivered by difference of absorption is sufficiently high for this spectral range. The dominance of X-ray tubes holds even more than 120 years after Conrad Roentgen's discovery of the bremsstrahlung mechanism. What are the specifics of current X-ray tubes and their medical diagnostic applications? How may the next available technology at or beyond the horizon look like? Can we hope for substantial game changers? Will flat panel sources, less expensive X-ray "LED's", compact X-ray Lasers, compact synchrotrons or equivalent X-ray sources appear in medical diagnostic imaging soon? After discussing the various modalities of imaging systems and their sources of radiation, this overview will briefly touch on the physics of bremsstrahlung generation, key characteristics of X-ray tubes, and material boundary conditions, which restrict performance. It will discuss the deficits of the bremsstrahlung technology and try to sketch future alternatives and their prospects of implementation in medical diagnostics.

  10. Diagnostic X-ray sources-present and future

    Science.gov (United States)

    Behling, Rolf; Grüner, Florian

    2018-01-01

    This paper compares very different physical principles of X-ray production to spur ideation. Since more than 120 years, bremsstrahlung from X-ray tubes has been the workhorse of medical diagnostics. Generated by X-ray segments comprised of X-ray tubes and high-voltage generators in the various medical systems, X-ray photons in the spectral range between about 16 keV and 150 keV deliver information about anatomy and function of human patients and in pre-clinical animal studies. Despite of strides to employ the wave nature of X-rays as phase sensitive means, commercial diagnostic X-ray systems available until the time of writing still rely exclusively on measuring the attenuation and scattering of X-rays by matter. Significant activities in research aim at building highly brilliant short pulse X-ray sources, based on e.g. synchrotron radiation, free electron lasers and/or laser wake-field acceleration of electrons followed by wiggling with magnetic structures or Thomson scattering in bunches of light. While both approaches, non-brilliant and brilliant sources, have different scope of application, we speculate that a combination may expand the efficacy in medical application. At this point, however, severe technical and commercial difficulties hinder closing this gap. This article may inspire further development and spark innovation in this important field.

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is taken ... and/or your insurance provider to get a better understanding of the possible charges you will incur. ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... is repeated. Two or three images (from different angles) will typically be taken. An x-ray may ... RadiologyInfo.org is not a medical facility. Please contact your physician with specific medical questions or for ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... no special preparation. Tell your doctor and the technologist if there is any possibility you are pregnant. ... should always inform their physician and x-ray technologist if there is any possibility that they are ...

  14. X-ray guided biopsy

    International Nuclear Information System (INIS)

    Casanova, R.; Lezana, A.H.; Pedrosa, C.S.

    1980-01-01

    Fine needle aspiration biopsy (FNAB) is now a routine procedure in many X-ray Departments. This paper presents the authors' experience with this technique in chest, abdominal and skeletal lesions. (Auth.)

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Radiography) - Bone Bone x-ray uses a very small dose of ionizing radiation to produce pictures of ... exposing a part of the body to a small dose of ionizing radiation to produce pictures of ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... replacement and fracture reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes seen in ... injuries, including fractures, and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely ...

  17. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral dental X-ray apparatus for panoramic dental radiography is described in detail. It comprises an electron gun having an elongated tubular target carrier extending into the patient's mouth. The carrier supports an inclined target for direction of an X-ray pattern towards a film positioned externally of the patient's mouth. Image definition is improved by a focusing anode which focuses the electron beam into a sharp spot (0.05 to 0.10 mm diameter) on the target. The potential on the focusing anode is adjustable to vary the size of the spot. An X-ray transmitting ceramic (oxides of Be, Al and Si) window is positioned adjacent to the front face of the target. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... procedure varies. See the Safety page for more information about radiation dose. Women should always inform their ...

  19. X-Ray Assembler Data

    Data.gov (United States)

    U.S. Department of Health & Human Services — Federal regulations require that an assembler who installs one or more certified components of a diagnostic x-ray system submit a report of assembly. This database...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... technologist, an individual specially trained to perform radiology examinations, positions the patient on the x-ray table ... bone is forming), for comparison purposes. When the examination is complete, you may be asked to wait ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... in a known abnormality can be monitored over time. Follow-up examinations are sometimes the best way ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the radiation while soft tissue, such as muscle, fat and organs, allow more of the x-rays ... taken of the unaffected limb, or of a child's growth plate (where new bone is forming), for ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the radiation while soft tissue, such as muscle, fat and organs, allow more of the x-rays ... information you were looking for? Yes No Please type your comment or suggestion into the following text ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. top of page What does ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images ... and places the x-ray film holder or digital recording plate under the table in the area ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... in metabolic conditions. assist in the detection and diagnosis of bone cancer . locate foreign objects in soft ... frequently compared to current x-ray images for diagnosis and disease management. top of page How is ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of any bone in the body, including the hand, wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg ( ... Image Gallery Radiological technologist preparing to take an arm x-ray on a ... Images related ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... care is taken during x-ray examinations to use the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different parts of the body absorb the x-rays in varying degrees. Dense ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-ray machine is a compact apparatus that can be taken to the patient in a hospital ... so that any change in a known abnormality can be monitored over time. Follow-up examinations are ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? A bone x-ray examination itself ... available in emergency rooms, physician offices, ambulatory care centers, nursing homes and other locations, making it convenient ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... will analyze the images and send a signed report to your primary care or referring physician , who ... Medicine Radiation Safety How to Read Your Radiology Report Images related to X-ray (Radiography) - Bone Sponsored ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams ... the web pages found at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... to produce pictures of any bone in the body. It is commonly used to diagnose fractured bones ... x-rays involves exposing a part of the body to a small dose of ionizing radiation to ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... to X-ray (Radiography) - Bone Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the baby. See the Safety page for more information about pregnancy and x-rays. top of page ... procedure varies. See the Safety page for more information about radiation dose. Women should always inform their ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... and fracture reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes seen in metabolic ... to current x-ray images for diagnosis and disease management. top of page How is the procedure ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... imaged. When necessary, sandbags, pillows or other positioning devices will be used to help you maintain the ... here Images × Image Gallery Radiological technologist preparing to take an arm x-ray on a patient. View ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... foot. top of page What are some common uses of the procedure? A bone x-ray is ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... taken of the unaffected limb, or of a child's growth plate (where new bone is forming), for ...

  2. Flash x-ray cinematography

    International Nuclear Information System (INIS)

    Stein, W.E.

    1976-01-01

    Experiments intended to provide an overview of the potential capabilities and limitations of flash x-ray cinematography as a diagnostic technique for a Fast Reactor Safety Test Facility are described. The results provide estimates of the x-ray pulse intensity required to obtain adequate radiographs of an array of fuel pins in a typical reactor configuration. An estimate of the upper limit on the pulse duration imposed by the reactor background radiation was also determined. X-ray cinematography has been demonstrated at a repetition rate limited only by the recording equipment on hand at the time of these measurements. These preliminary results indicate that flash x-ray cinematography of the motion of fuel in a Fast Reactor Test Facility is technically feasible

  3. X-ray luminescent glasses

    International Nuclear Information System (INIS)

    Takahashi, T.; Yamada, O.

    1981-01-01

    X-ray luminescent glasses comprising a divalent cation such as an alkaline earth metal or other divalent cations such as pb, cd, or zn, and certain rare earth metaphosphates are suitable as vitreous, x-ray phosphors or x-ray luminescent glass fibers in an x-ray intensifying screen. The glasses have the composition n(Mo X p2o5)((1-y)tb2o3 X yce2o3 X 3p2o5) wherein N is greater than zero but less than or equal to 16, M is an alkaline earth metal or other divalent cation such as pb, cd, or zn, and Y is greater than or equal to zero but less than one

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-ray uses a very small dose of ionizing radiation to produce pictures of any bone in the ... of the body to a small dose of ionizing radiation to produce pictures of the inside of the ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... examination may also be necessary so that any change in a known abnormality can be monitored over ...

  6. Miniature x-ray source

    Science.gov (United States)

    Trebes, James E.; Bell, Perry M.; Robinson, Ronald B.

    2000-01-01

    A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

  7. Duodenal X-ray diagnostics

    International Nuclear Information System (INIS)

    Scheppach, W.

    1982-01-01

    The publication provides an overview of duodenal X-ray diagnostics with the aid of barium meals in 1362 patients. The introducing paragraphs deal with the topographic anatomy of the region and the methodics of X-ray investigation. The chapter entitled ''processes at the duodenum itself'' describes mainly ulcers, diverticula, congenital anomalies, tumors and inflammations. The neighbourhood processes comprise in the first place diseases having their origin at the pancreas and bile ducts. As a conclusion, endoscopic rectograde cholangio-pancreaticography and percutaneous transhepatic cholangiography are pointed out as advanced X-ray investigation methods. In the annex of X-ray images some of the described phenomena are shown in exemplary manner. (orig./MG) [de

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... fracture. guide orthopedic surgery, such as spine repair/fusion, joint replacement and fracture reductions. look for injury, ... CT Exams Arthritis X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety How to Read Your Radiology ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the oldest and most frequently used form of medical imaging. A bone x-ray makes images of any ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... carefully aimed at the part of the body being examined, an x-ray machine produces a small ... the table in the area of the body being imaged. When necessary, sandbags, pillows or other positioning ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ... minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown. ... appliances, eye glasses and any metal objects or clothing that might interfere with the x-ray images. ...

  15. Magnetic x-ray microdiffraction

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Paul G [Computer-Aided Engineering Center, University of Wisconsin, Madison, WI 53706 (United States); Isaacs, Eric D [Center for Nanoscale Materials, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2006-08-07

    Magnetic x-ray microdiffraction uses the structural specificity of x-ray diffraction to probe complex magnetic structures at the length scales relevant to physical phenomena including domain dynamics and phase transitions. Conventional magnetic crystallography techniques such as neutron or x-ray diffraction lack this spatial resolution. The combination of both reciprocal space and real space resolution with a rich magnetic cross section allows new microscopy techniques to be developed and applied to magnetism at the scale of single domains. Potential applications include a wide range of magnetic problems in nanomagnetism, the interaction of strain, polarization and magnetization in complex oxides and spatially resolved studies of magnetic phase transitions. We present the physical basis for x-ray microdiffraction and magnetic scattering processes, review microdiffraction domain imaging techniques in antiferromagnetic and ferromagnetic materials and discuss potential directions for studies. (topical review)

  16. EOL3 M0 X-ray Tomography Test Results

    CERN Document Server

    Avramidou, R; Bozhko, N; Borisov, A; Goriatchev, V; Goriatchev, S; Gushin, V; Fakhroutdinov, R; Kojine, A; Kononov, A; Larionov, A; Salomatin, Yu I; Schuh, S; Sedykh, Yu; Tchougouev, A

    2001-01-01

    Results of X-ray tomography test of EOL3 module 0 chamber is presented in the note. Peculiarities of the X-ray tomography of the chamber are discussed. Comparison of the tomography results with predictions of the production site measurements is made.

  17. Electromechanical x-ray generator

    Science.gov (United States)

    Watson, Scott A; Platts, David; Sorensen, Eric B

    2016-05-03

    An electro-mechanical x-ray generator configured to obtain high-energy operation with favorable energy-weight scaling. The electro-mechanical x-ray generator may include a pair of capacitor plates. The capacitor plates may be charged to a predefined voltage and may be separated to generate higher voltages on the order of hundreds of kV in the AK gap. The high voltage may be generated in a vacuum tube.

  18. Accelerator x-ray sources

    CERN Document Server

    Talman, Richard

    2007-01-01

    This first book to cover in-depth the generation of x-rays in particle accelerators focuses on electron beams produced by means of the novel Energy Recovery Linac (ERL) technology. The resulting highly brilliant x-rays are at the centre of this monograph, which continues where other books on the market stop. Written primarily for general, high energy and radiation physicists, the systematic treatment adopted by the work makes it equally suitable as an advanced textbook for young researchers.

  19. X-ray tube target

    International Nuclear Information System (INIS)

    Weber, R.G.

    1980-01-01

    A target with an improved heat emissive surface for use in a rotating anode type x-ray tube is described. The target consists of a body having a first surface portion made of x-ray emissive material and a second surface portion made of a heat emissive material comprising at least one of hafnium boride, hafnium oxide, hafnium nitride, hafnium silicide, and hafnium aluminide. (U.K.)

  20. X-ray fluorescence holography

    CERN Document Server

    Hayashi, K; Takahashi, Y

    2003-01-01

    X-ray fluorescence holography (XFH) is a new structural analysis method of determining a 3D atomic arrangement around fluorescing atoms. We developed an XFH apparatus using advanced X-ray techniques and succeeded in obtaining high-quality hologram data. Furthermore, we introduced applications to the structural analysis of a thin film and the environment around dopants and, discussed the quantitative analysis of local lattice distortion. (author)

  1. X-ray data processing

    OpenAIRE

    Powell, Harold R.

    2017-01-01

    The method of molecular structure determination by X-ray crystallography is a little over a century old. The history is described briefly, along with developments in X-ray sources and detectors. The fundamental processes involved in measuring diffraction patterns on area detectors, i.e. autoindexing, refining crystal and detector parameters, integrating the reflections themselves and putting the resultant measurements on to a common scale are discussed, with particular reference to the most c...

  2. Study of fission products (Cs, Ba, Mo, Ru) behaviour in irradiated and simulated nuclear fuels during severe accidents using X-ray absorption Spectroscopy, SIMS and EPMA

    International Nuclear Information System (INIS)

    Geiger, Ernesto

    2016-01-01

    The identification of Fission Products (FP) release mechanism from irradiated nuclear fuels during a severe accident is of main importance for the development of codes for the estimation of the source-term (nature and quantity of radionuclides released into the environment). among the many FP Ba, Cs, Mo and Ru present a particular interest, since they may interact with each other or other elements and thus affect their release. In the framework of this thesis, two work axes have been set up in order to identify, firstly, the chemical phases initially present before the accident and, secondly, their evolution during the accident itself. The experimental approach consisted in reproducing nuclear severe accidents conditions at laboratory scale using both irradiated fuels and model materials (natural UO_2 doped with 12 FP). The advantage of these latter is the possibility of using characterization methods such as X-ray absorption Spectroscopy which are not available for irradiated fuels. Three irradiated fuel samples have been studied, representative to an initial state (before the accident), to an intermediate stage (1773 K) and to an advanced stage (2873 K) of a nuclear severe accident. Regarding to model materials, many accident sequences have been carried out, from 573 to 1973 K. Experimental results have allowed to establish a new release mechanism, considering both reducing and oxidizing conditions during an accident. These results have also demonstrated the importance of model materials as a complement to irradiated nuclear fuels in the study of nuclear severe accidents. (author) [fr

  3. Cross Sections for K-shell X-ray Production by Hydrogen and Helium Ions in Elements from Beryllium to Uranium

    International Nuclear Information System (INIS)

    Lapicki, G.

    1989-01-01

    Experimental cross sections for K-shell x-ray production by hydrogen and helium ions (Z 1 = 1,2) in target atoms from beryllium to uranium (Z 2 = 4--92 ) are tabulated as compiled (7418 cross sections) from the literature (161 references were found) with the search for the data terminated in January 1988. These cross sections are compared with predictions of the first Born approximation and ECPSSR theory for inner-shell ionization. The ECPSSR accounts for the energy loss (E) and Coulomb deflection (C) of the projectile ion as well as for the perturbed stationary state (PSS) and relativistic (R) nature of the target's inner-shell electron.While the first Born approximation generally overestimates the data by orders of magnitude, the ECPSSR theory is confirmed to be, on the average, in agreement with the experiment to within 10%--20%. For light and heavy target atoms, however, systematic and opposite deviations are found in the low projectile-velocity regime. These deviations are associated with the influence of multiple outer-shell ionizations on the fluorescence yields of light elements, particularly in ionization by helium ions, and with the inaccuracy of the ECPSSR theory in the reproduction of relativistic calculations for ionization of heavy elements. The remaining discrepancies at moderate projectile velocities are prima facie attributed to inadequacies of a screened hydrogenic description for the K-shell electron

  4. An X-ray photoelectron spectroscopy study of the products of the interaction of gaseous IrF6 with fine UO2F2

    Directory of Open Access Journals (Sweden)

    Prusakov Vladimir N.

    2007-01-01

    Full Text Available Nuclear fuel reprocessing by fluorination, a dry method of regeneration of spent nuclear fuel, uses UO2F2 for the separation of plutonium from gaseous mixtures. Since plutonium requires special treatment, IrF6 was used as a thermodynamic model of PuF6. The model reaction of the interaction of gaseous IrF6 with fine UO2F2 in the sorption column revealed a change of color of the sorption column contents from pale-yellow to gray and black, indicating the formation of products of such an interaction. The X-ray photoelectron spectroscopy study showed that the interaction of gaseous IrF6 with fine UO2F2 at 125 °C results in the formation of stable iridium compounds where the iridium oxidation state is close to Ir3+. The dependence of the elemental compositions of the layers in the sorption column on the penetration depth of IrF6 was established.

  5. Low energy (soft) x rays

    International Nuclear Information System (INIS)

    Hoshi, Masaharu; Antoku, Shigetoshi; Russell, W.J.; Miller, R.C.; Nakamura, Nori; Mizuno, Masayoshi; Nishio, Shoji.

    1987-05-01

    Dosimetry of low-energy (soft) X rays produced by the SOFTEX Model CMBW-2 was performed using Nuclear Associates Type 30 - 330 PTW, Exradin Type A2, and Shonka-Wyckoff ionization chambers with a Keithley Model 602 electrometer. Thermoluminescent (BeO chip) dosimeters were used with a Harshaw Detector 2000-A and Picoammeter-B readout system. Beam quality measurements were made using aluminum absorbers; exposure rates were assessed by the current of the X-ray tube and by exposure times. Dose distributions were established, and the average factors for non-uniformity were calculated. The means of obtaining accurate absorbed and exposed doses using these methods are discussed. Survival of V79 cells was assessed by irradiating them with soft X rays, 200 kVp X rays, and 60 Co gamma rays. The relative biological effectiveness (RBE) values for soft X rays with 0, 0.2, 0.7 mm added thicknesses of aluminum were 1.6, which were compared to 60 Co. The RBE of 200 kVp X rays relative to 60 Co was 1.3. Results of this study are available for reference in future RERF studies of cell survival. (author)

  6. Center for X-Ray Optics, 1992

    International Nuclear Information System (INIS)

    1993-08-01

    This report discusses the following topics: Center for X-Ray Optics; Soft X-Ray Imaging wit Zone Plate Lenses; Biological X-Ray microscopy; Extreme Ultraviolet Lithography for Nanoelectronic Pattern Transfer; Multilayer Reflective Optics; EUV/Soft X-ray Reflectometer; Photoemission Microscopy with Reflective Optics; Spectroscopy with Soft X-Rays; Hard X-Ray Microprobe; Coronary Angiography; and Atomic Scattering Factors

  7. Study on TV X-ray system characteristics

    International Nuclear Information System (INIS)

    Semenov, A.P.; Volkov, A.V.

    1978-01-01

    The results are presented of comparative investigations into the main characteristics of TV X-ray systems (TXS) and X-ray radiography when X-raying of the 1Kh18N9T steel. The following characteristics are considered: the threshold contrast sensitivity, the sensitivity to revealing standard defects, and the dose rate of X-radiation at the input of the X-ray converter. Practical recommendations are given on the use of TXS in flaw detection of various materials. It is remarked to use introscopes for testing of thick welded products articles, and X-ray vidicon systems for study of low-contrast images (in testing of welds made by point welding, and of thin-wall products)

  8. Evaluation of a new optic-enabled portable X-ray fluorescence spectrometry instrument for measuring toxic metals/metalloids in consumer goods and cultural products

    Science.gov (United States)

    Guimarães, Diana; Praamsma, Meredith L.; Parsons, Patrick J.

    2016-08-01

    X-ray fluorescence spectrometry (XRF) is a rapid, non-destructive multi-elemental analytical technique used for determining elemental contents ranging from percent down to the μg/g level. Although detection limits are much higher for XRF compared to other laboratory-based methods, such as inductively coupled plasma mass spectrometry (ICP-MS), ICP-optical emission spectrometry (OES) and atomic absorption spectrometry (AAS), its portability and ease of use make it a valuable tool, especially for field-based studies. A growing necessity to monitor human exposure to toxic metals and metalloids in consumer goods, cultural products, foods and other sample types while performing the analysis in situ has led to several important developments in portable XRF technology. In this study, a new portable XRF analyzer based on the use of doubly curved crystal optics (HD Mobile®) was evaluated for detecting toxic elements in foods, medicines, cosmetics and spices used in many Asian communities. Two models of the HD Mobile® (a pre-production and a final production unit) were investigated. Performance parameters including accuracy, precision and detection limits were characterized in a laboratory setting using certified reference materials (CRMs) and standard solutions. Bias estimates for key elements of public health significance such as As, Cd, Hg and Pb ranged from - 10% to 11% for the pre-production, and - 14% to 16% for the final production model. Five archived public health samples including herbal medicine products, ethnic spices and cosmetic products were analyzed using both XRF instruments. There was good agreement between the pre-production and final production models for the four key elements, such that the data were judged to be fit-for-purpose for the majority of samples analyzed. Detection of the four key elements of interest using the HD Mobile® was confirmed using archived samples for which ICP-OES data were available based on digested sample materials. The HD

  9. Simulation of a dense plasma focus x-ray source

    International Nuclear Information System (INIS)

    Stark, R.A.

    1994-01-01

    The authors are performing simulations of the magnetohydrodynamics of a Dense Plasma Focus (DPF) x-ray source located at Science Research Laboratory (SRL), Alameda, CA, in order to optimize its performance. The SRL DPF, which was developed as a compact source for x-ray lithography, operates at 20 Hz, giving x-ray power (9--14 Angstroms) of 500 W using neon gas. The simulations are performed with the two dimensional MHD code MACH2, developed by Mission Research Corporation, with a steady state corona model as the equation of state. The results of studies of the sensitivity of x-ray output to charging voltage and current, and to initial gas density will be presented. These studies should indicate ways to optimize x-ray production efficiency. Simulations of various inner electrode configurations will also be presented

  10. Nanofocusing refractive X-ray lenses

    Energy Technology Data Exchange (ETDEWEB)

    Boye, Pit

    2010-02-05

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  11. Nanofocusing refractive X-ray lenses

    International Nuclear Information System (INIS)

    Boye, Pit

    2010-01-01

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  12. Transmission X-ray mirror

    International Nuclear Information System (INIS)

    Lairson, B.M.; Bilderback, D.H.

    1982-01-01

    Transmission X-ray mirrors have been made from 400 A to 10 000 A thick soap films and have been shown to have novel properties. Using grazing angles of incidence, low energy X-rays were reflected from the front surface while more energetic X-rays were transmitted through the mirror largely unattenuated. A wide bandpass monochromator was made from a silicon carbide mirror followed by a soap film transmission mirror and operated in the white beam at the cornell High Energy Synchrotron Source (CHESS). Bandpasses of ΔE/E=12% to 18% were achieved at 13 keV with peak efficiencies estimated to be between 55% and 75%, respectively. Several wide angle scattering photographs of stretched polyethylene and a phospholipid were obtained in 10 s using an 18% bandpass. (orig.)

  13. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral X-ray apparatus which reduces the number of exposures necessary to obtain panoramic dental radiographs is described in detail. It comprises an electron gun, a tubular target carrier projecting from the gun along the beam axis and carrying at its distal end a target surrounded by a shield of X-ray opaque material. This shield extends forward and laterally of the target and has surfaces which define a wedge or cone-shaped radiation pattern delimited vertically by the root tips of the patient's teeth. A film holder is located externally of the patient's mouth. A disposable member can fit on the target carrier to depress the patient's tongue out of the radiation pattern and to further shield the roof of the mouth. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  14. Exponential x-ray transform

    International Nuclear Information System (INIS)

    Hazou, I.A.

    1986-01-01

    In emission computed tomography one wants to determine the location and intensity of radiation emitted by sources in the presence of an attenuating medium. If the attenuation is known everywhere and equals a constant α in a convex neighborhood of the support of f, then the problem reduces to that of inverting the exponential x-ray transform P/sub α/. The exponential x-ray transform P/sub μ/ with the attenuation μ variable, is of interest mathematically. For the exponential x-ray transform in two dimensions, it is shown that for a large class of approximate δ functions E, convolution kernels K exist for use in the convolution backprojection algorithm. For the case where the attenuation is constant, exact formulas are derived for calculating the convolution kernels from radial point spread functions. From these an exact inversion formula for the constantly attenuated transform is obtained

  15. X-ray of osteopathies

    International Nuclear Information System (INIS)

    Freyschmidt, J.

    1980-01-01

    Osteoporosis, osteomalcia, fibro-osteoclasia and osteosclerosis are essential reactions to pathologicometabolic processes of the bone. The X-ray film shows precisely which changes have taken place in the bone structure, thus supplying the means for an analysis based on anatomic pathology. These phenomena are discussed in detail, special attention being paid to structural modifications. Attention is also focused on the problems connected with X-ray technology. The value of direct and indirect magnification of the skeleton of the hand for the identification and classification of esteopathies is explained. Phenomena observed in X-ray films, such as enosteal erosion, intracortical longitudinal stripes or tunnelisation, as well as subperiostal absorption, can be of pathognomonic importance for certain osteopathies. (orig.) [de

  16. Imaging X-ray astronomy

    International Nuclear Information System (INIS)

    Elvis, M.

    1990-01-01

    The launch of the High Energy Astrophysical Observatory, more appealingly called the Einstein Observatory, marked one of the most revolutionary steps taken in astrophysics this century. Its greater sensitivity compared with earlier satellites and its ability to make high spacial and spectral resolution observations transformed X-ray astronomy. This book is based on a Symposium held in Cambridge, Massachusetts, to celebrate a decade of Einstein Observatory's achievements. It discusses the contributions that this satellite has made to each area of modern astrophysics and the diversity of the ongoing work based on Einstein data. There is a guide to each of the main data bases now coming on-line to increase the availability and to preserve this valuable archive for the future. A review of NASA's next big X-ray mission, AXAF, and a visionary program for novel X-ray astronomy satellites by Riccardo Giacconi conclude this wide-ranging volume. (author)

  17. Solar X-ray bursts

    International Nuclear Information System (INIS)

    Urnov, A.M.

    1980-01-01

    In the popular form the consideration is given to the modern state tasks and results of X-ray spectrometry of solar bursts. The operation of X-ray spectroheliograph is described. Results of spectral and polarization measurings of X-ray radiation of one powerful solar burst are presented. The conclusion has been drawn that in the process of burst development three characteristic stages may be distingwished: 1) the initial phase; just in this period processes which lead to observed consequences-electromagnetic and corpuscular radiation are born; 2) the impulse phase, or the phase of maximum, is characterised by sharp increase of radiation flux. During this phase the main energy content emanates and some volumes of plasma warm up to high temperatures; 3) the phase of burst damping, during which plasma cools and reverts to the initial condition

  18. X-ray fluorescence holography.

    Science.gov (United States)

    Hayashi, Kouichi; Happo, Naohisa; Hosokawa, Shinya; Hu, Wen; Matsushita, Tomohiro

    2012-03-07

    X-ray fluorescence holography (XFH) is a method of atomic resolution holography which utilizes fluorescing atoms as a wave source or a monitor of the interference field within a crystal sample. It provides three-dimensional atomic images around a specified element and has a range of up to a few nm in real space. Because of this feature, XFH is expected to be used for medium-range local structural analysis, which cannot be performed by x-ray diffraction or x-ray absorption fine structure analysis. In this article, we explain the theory of XFH including solutions to the twin-image problem, an advanced measuring system, and data processing for the reconstruction of atomic images. Then, we briefly introduce our recent applications of this technique to the analysis of local lattice distortions in mixed crystals and nanometer-size clusters appearing in the low-temperature phase of a shape-memory alloy.

  19. X-ray fluorescence holography

    International Nuclear Information System (INIS)

    Hayashi, Kouichi; Happo, Naohisa; Hosokawa, Shinya; Hu Wen; Matsushita, Tomohiro

    2012-01-01

    X-ray fluorescence holography (XFH) is a method of atomic resolution holography which utilizes fluorescing atoms as a wave source or a monitor of the interference field within a crystal sample. It provides three-dimensional atomic images around a specified element and has a range of up to a few nm in real space. Because of this feature, XFH is expected to be used for medium-range local structural analysis, which cannot be performed by x-ray diffraction or x-ray absorption fine structure analysis. In this article, we explain the theory of XFH including solutions to the twin-image problem, an advanced measuring system, and data processing for the reconstruction of atomic images. Then, we briefly introduce our recent applications of this technique to the analysis of local lattice distortions in mixed crystals and nanometer-size clusters appearing in the low-temperature phase of a shape-memory alloy. (topical review)

  20. A survey on coordinate metrology using dimensional X-ray CT

    International Nuclear Information System (INIS)

    Matsuzaki, Kazuya

    2016-01-01

    X-ray computed tomography (X-ray CT) has been occupying indispensable position in geometrical and dimensional measurements in industry, which is capable of measuring both external and internal dimensions of industrial products. Since dimensional X-ray CT has problems about ensuring traceability and estimating uncertainty, requirement of developing measurement standard for dimensional X-ray CT is increasing. Some of national metrology institutes (NMIs) including NMIJ have been working on developing measurement standard. In this report, the background of coordinate metrology using dimensional X-ray CT is reviewed. Then, measurement error sources are discussed. Finally, the plan to develop high accuracy dimensional X-ray CT is presented. (author)

  1. Overutilization of x-rays

    International Nuclear Information System (INIS)

    Abrams, H.L.

    1979-01-01

    In this article on the overutilization of x-rays the author defines the term overutilization as excessive irradiation per unit of diagnostic information, therapeutic impact, or health outcome. Three main factors are described which lead to overutilization of x-rays: excessive radiation per film; excessive films per examination; and excessive examinations per patient. Topics discussed which influence the excessive examinations per patient are: the physician's lack of knowledge; undue dependence; lack of screening by radiologists; the physician's need for action and certainty; patient demand; reimbursement policies; institutional requirements; preventive medicine; defensive medicine; and the practice of radiology by nonradiologists

  2. Multichannel X-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Khabakhpashev, A

    1980-10-01

    A typical design is discussed of multiwire proportional counters and their characteristic feature is explained, ie., the possibility of showing one or two coordinates of the X-ray quantum absorption site. The advantages of such instruments are listed, such as increased sensitivity of determination, the possibility of recording radiations of a different intensity, the possibility of on-line data processing and of the digital display of results. The fields of application include X-ray structural analysis in solid state physics, crystallography, molecular biology, astronomy, materials testing, and medicine.

  3. Semiconductor X-ray spectrometers

    International Nuclear Information System (INIS)

    Muggleton, A.H.F.

    1978-02-01

    An outline is given of recent developments in particle and photon induced x-ray fluorescence (XRF) analysis. Following a brief description of the basic mechanism of semiconductor detector operation a comparison is made between semiconductor detectors, scintillators and gas filled proportional devices. Detector fabrication and cryostat design are described in more detail and the effects of various device parameters on system performance, such as energy resolution, count rate capability, efficiency, microphony, etc. are discussed. The main applications of these detectors in x-ray fluorescence analysis, electron microprobe analysis, medical and pollution studies are reviewed

  4. Portable X-Ray Device

    Science.gov (United States)

    1983-01-01

    Portable x-ray instrument developed by NASA now being produced commercially as an industrial tool may soon find further utility as a medical system. The instrument is Lixiscope - Low Intensity X-Ray Imaging Scope -- a self-contained, battery-powered fluoroscope that produces an instant image through use of a small amount of radioactive isotope. Originally developed by Goddard Space Flight Center, Lixiscope is now being produced by Lixi, Inc. which has an exclusive NASA license for one version of the device.

  5. X-ray tube targets

    International Nuclear Information System (INIS)

    Hirsch, H.H.

    1980-01-01

    In rotary targets for X-ray tubes warping is a problem which causes X-ray deficiency. A rotary target is described in which warping is reduced by using alloys of molybdenum with 0.05 to 10% iron, silicon, cobalt, tantalum, niobium, hafnium, stable metal oxide or mixture thereof. Suitable mixtures are 0.5 to 10% of tantalum, niobium or hafnium with from 0.5 to 5% yttrium oxide, or 0.05 to 0.3% of cobalt or silicon. Optionally 0.1 to 5% by weight of additional material may be alloyed with the molybdenum, such as tantalum or hafnium carbides. (author)

  6. X-ray data processing.

    Science.gov (United States)

    Powell, Harold R

    2017-10-31

    The method of molecular structure determination by X-ray crystallography is a little over a century old. The history is described briefly, along with developments in X-ray sources and detectors. The fundamental processes involved in measuring diffraction patterns on area detectors, i.e. autoindexing, refining crystal and detector parameters, integrating the reflections themselves and putting the resultant measurements on to a common scale are discussed, with particular reference to the most commonly used software in the field. © 2017 The Author(s).

  7. X-ray Emission from Solar Flares

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... Solar flares; X-ray detectors; X-ray line emission and continuum; break energy; microflares. Abstract. Solar X-ray Spectrometer (SOXS), the first space-borne solar astronomy experiment of India was designed to improve our current understanding of X-ray emission from the Sun in general and solar flares in ...

  8. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... Resources Professions Site Index A-Z X-ray (Radiography) - Chest Chest x-ray uses a very small dose ... Radiography? What is a Chest X-ray (Chest Radiography)? The chest x-ray is the most commonly performed diagnostic ...

  9. X-Ray Exam: Cervical Spine

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Cervical Spine KidsHealth / For Parents / X-Ray ... MRI): Lumbar Spine Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  10. X-Ray Exam: Neck (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Neck KidsHealth / For Parents / X-Ray Exam: ... Neck Enlarged Adenoids Croup Sinusitis Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  11. Illumination system for X-ray lithography

    International Nuclear Information System (INIS)

    Buckley, W.D.

    1989-01-01

    An X-ray lithography system is described, comprising: a point source of X-Ray radiation; a wafer plane disposed in spaced relation to the point source of X-Ray radiation; a mask disposed between the point source of X-Ray radiation and the wafer plane whereby X-Ray radiation from the point source of X-ray radiation passes through the mask to the water plane; and X-Ray absorbent means mounted between the point source of X-Ray radiation and the wafer plane, the X-Ray absorbent means being of quadratically absorption from maximum absorption at the center to minimum absorption at the edge so as to have a radial absorption gradient profile to compensate for radial flux variation of the X-Ray radiation

  12. Towards attosecond X-ray pulses from the FEL

    International Nuclear Information System (INIS)

    Zholents, Alexander A.; Fawley, William M.

    2004-01-01

    The ability to study ultrafast phenomena has been recently advanced by the demonstrated production and measurement of a single, 650-attosecond (10 18 sec), VUV x-ray pulse[1] and, latter, a 250-attosecond pulse[2]. The next frontier is a production of the x-ray pulses with shorter wavelengths and in a broader spectral range. Several techniques for a generation of an isolated, attosecond duration, short-wavelength x-ray pulse based upon the ponderomotive laser acceleration [3], SASE and harmonic cascade FELs ([4] - [6]) had been already proposed. In this paper we briefly review a technique proposed in [5] and present some new results

  13. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors

  14. X-ray hot plasma diagnostics

    International Nuclear Information System (INIS)

    Cojocaru, E.

    1984-11-01

    X-ray plasma emission study is powerful diagnostic tool of hot plasmas. In this review article the main techniques of X-ray plasma emission measurement are shortly presented: X-ray spectrometry using absorbent filters, crystal and grating spectrometers, imaging techniques using pinhole cameras, X-ray microscopes and Fresnel zone plate cameras, X-ray plasma emission calorimetry. Advances in these techniques with examples for different hot plasma devices are also presentes. (author)

  15. The Mapping X-ray Fluorescence Spectrometer (MapX)

    Science.gov (United States)

    Sarrazin, P.; Blake, D. F.; Marchis, F.; Bristow, T.; Thompson, K.

    2017-12-01

    Many planetary surface processes leave traces of their actions as features in the size range 10s to 100s of microns. The Mapping X-ray Fluorescence Spectrometer (MapX) will provide elemental imaging at 100 micron spatial resolution, yielding elemental chemistry at a scale where many relict physical, chemical, or biological features can be imaged and interpreted in ancient rocks on planetary bodies and planetesimals. MapX is an arm-based instrument positioned on a rock or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample with X-rays or alpha-particles / gamma-rays, resulting in sample X-ray Fluorescence (XRF). X-rays emitted in the direction of an X-ray sensitive CCD imager pass through a 1:1 focusing lens (X-ray micro-pore Optic (MPO)) that projects a spatially resolved image of the X-rays onto the CCD. The CCD is operated in single photon counting mode so that the energies and positions of individual X-ray photons are recorded. In a single analysis, several thousand frames are both stored and processed in real-time. Higher level data products include single-element maps with a lateral spatial resolution of 100 microns and quantitative XRF spectra from ground- or instrument- selected Regions of Interest (ROI). XRF spectra from ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. When applied to airless bodies and implemented with an appropriate radioisotope source for alpha-particle excitation, MapX will be able to analyze biogenic elements C, N, O, P, S, in addition to the cations of the rock-forming elements >Na, accessible with either X-ray or gamma-ray excitation. The MapX concept has been demonstrated with a series of lab-based prototypes and is currently under refinement and TRL maturation.

  16. X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Vries, J.L. de.

    1976-01-01

    The seventh edition of Philips' Review of Literature on x-ray fluorescence spectrometry starts with a list of conference proceedings on the subject, organised by the Philips organisation at regular intervals in various European countries. It is followed by a list of bulletins. The bibliography is subdivided according to spectra, equipment, applications and absorption analysis

  17. Stellar X-Ray Polarimetry

    Science.gov (United States)

    Swank, J.

    2011-01-01

    Most of the stellar end-state black holes, pulsars, and white dwarfs that are X-ray sources should have polarized X-ray fluxes. The degree will depend on the relative contributions of the unresolved structures. Fluxes from accretion disks and accretion disk corona may be polarized by scattering. Beams and jets may have contributions of polarized emission in strong magnetic fields. The Gravity and Extreme Magnetism Small Explorer (GEMS) will study the effects on polarization of strong gravity of black holes and strong magnetism of neutron stars. Some part of the flux from compact stars accreting from companion stars has been reflected from the companion, its wind, or accretion streams. Polarization of this component is a potential tool for studying the structure of the gas in these binary systems. Polarization due to scattering can also be present in X-ray emission from white dwarf binaries and binary normal stars such as RS CVn stars and colliding wind sources like Eta Car. Normal late type stars may have polarized flux from coronal flares. But X-ray polarization sensitivity is not at the level needed for single early type stars.

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone ...

  19. X-ray Sensitive Material

    Science.gov (United States)

    2015-12-01

    TM 8772 5 Literature reports on BiI3/nylon composites used X-ray sources with a Mo target (Reference 18) or magnesium target (Reference 19). However...1981. Pp. D-155 to D-160. 22. G. Pretzsch, B. Dorschel, and T. Schonmuth. IEEE Transactions on Electrical Insulation, Vol. EI -21, No.3, June 1986

  20. X-ray system analysis

    International Nuclear Information System (INIS)

    Shapiro, J.S.

    1985-01-01

    An X-ray system tester for measuring anode voltage, cathode voltage, anode current, filament current and line voltage in an X-ray system has a selector which couples one of these analog signals or one of a plurality of processing control signals entered by an operator from a control panel to a digitizing section selectively in accordance with control signals provided to the selector by a computing section. The digitizing section converts the selected signal into a train of pulses having a frequency proportional to the value of the selected signal. These pulses are counted, the counts being used by the computing section to determine the value of the selected signal. This computed value is stored in a computing memory section of the computing section. The computing section is adapted to store a plurality of the sets of signals produced during a corresponding sequence of operational intervals of the X-ray system and determines a measure of the deviation of any selected one of the stored electrical signals over the sequence of operating intervals. Each signal produced during the sequential operational intervals can be recalled to aid analysis of the operation of the X-ray system. (author)

  1. X-ray image coding

    International Nuclear Information System (INIS)

    1974-01-01

    The invention aims at decreasing the effect of stray radiation in X-ray images. This is achieved by putting a plate between source and object with parallel zones of alternating high and low absorption coefficients for X-radiation. The image is scanned with the help of electronic circuits which decode the signal space coded by the plate, thus removing the stray radiation

  2. X-ray simulation development

    International Nuclear Information System (INIS)

    Posey, L.D.; Tollefsrud, P.B.; Woodall, H.W.; McDaniel, D.H.; Allred, R.E.

    1975-01-01

    Design modifications are discussed for an electron beam accelerator used as a Bremsstrahlung x-ray source. The primary goal of the program, to obtain a reliable 5 cal/gm exposure capability, can be accomplished with beam compression by an external magnetic guide field. Initial operating characteristics and performance improvements are presented

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit of an accurate ...

  4. X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ray, N.B.

    1977-01-01

    The principle, instrument and procedure of X-ray fluorescence spectrometry are described. It is a rapid, simple and sensitive method for the trace analysis of elements from sodium to uranium in powder, liquid or metal samples. (M.G.B.)

  5. X-rays from stars

    Science.gov (United States)

    Güdel, Manuel

    2004-07-01

    Spectroscopic studies available from Chandra and XMM-Newton play a pivotal part in the understanding of the physical processes in stellar (magnetic and non-magnetic) atmospheres. It is now routinely possible to derive densities and to study the influence of ultraviolet radiation fields, both of which can be used to infer the geometry of the radiating sources. Line profiles provide important information on bulk mass motions and attenuation by neutral matter, e.g. in stellar winds. The increased sensitivity has revealed new types of X-ray sources in systems that were thought to be unlikely places for X-rays: flaring brown dwarfs, including rather old, non-accreting objects, and terminal shocks in jets of young stars are important examples. New clues concerning the role of stellar high-energy processes in the modification of the stellar environment (ionization, spallation, etc.) contribute significantly to our understanding of the "astro-ecology" in forming planetary systems. Technological limitations are evident. The spectral resolution has not reached the level where bulk mass motions in cool stars become easily measurable. Higher resolution would also be important to perform X-ray "Doppler imaging" in order to reconstruct the 3-D distribution of the X-ray sources around a rotating star. Higher sensitivity will be required to perform high-resolution spectroscopy of weak sources such as brown dwarfs or embedded pre-main-sequence sources. A new generation of satellites such as Constellation-X or XEUS should pursue these goals.

  6. Chandra's X-ray Vision

    Indian Academy of Sciences (India)

    1999-07-23

    Jul 23, 1999 ... CXO is 13.8 metres long and its solar arrays have a wingspan of. 19.5 metres as shown in ... the Universe (for example, coronae of stars, matter ejected from .... The telescope system and the scientific instruments were put through ..... solve the puzzle about the origin of cosmic X-ray background- one of the ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  8. Stellar X-ray sources

    International Nuclear Information System (INIS)

    Katz, J.I.; Washington Univ., St. Louis, MO

    1988-01-01

    I Review some of the salient accomplishments of X-rap studies of compact objects. Progress in this field has closely followed the improvement of observational methods, particularly in angular resolution and duration of exposure. Luminous compact X-ray sources are accreting neutron stars or black holes. Accreting neutron stars may have characteristic temporal signatures, but the only way to establish that an X-ray source is a black hole is to measure its mass. A rough phenomenological theory is succesful, but the transport of angular momentum in accretion flows is not onderstood. A number of interesting complications have been observed, including precessing accretion discs, X-ray bursts, and the acceleration of jets in SS433. Many puzzles remain unsolved, including the excitation of disc precession, the nature of the enigmatic A- and gamma-ray source Cyg X-3, the mechanism by which slowly spinning accreting neutron stars lose angular momentum, and the superabundance of X-ray sources in globular clusters. 41 refs.; 5 figs

  9. X-rays and magnetism

    International Nuclear Information System (INIS)

    Fischer, Peter; Ohldag, Hendrik

    2015-01-01

    Magnetism is among the most active and attractive areas in modern solid state physics because of intriguing phenomena interesting to fundamental research and a manifold of technological applications. State-of-the-art synthesis of advanced magnetic materials, e.g. in hybrid structures paves the way to new functionalities. To characterize modern magnetic materials and the associated magnetic phenomena, polarized x-rays have emerged as unique probes due to their specific interaction with magnetic materials. A large variety of spectroscopic and microscopic techniques have been developed to quantify in an element, valence and site-sensitive way properties of ferro-, ferri-, and antiferromagnetic systems, such as spin and orbital moments, and to image nanoscale spin textures and their dynamics with sub-ns time and almost 10 nm spatial resolution. The enormous intensity of x-rays and their degree of coherence at next generation x-ray facilities will open the fsec time window to magnetic studies addressing fundamental time scales in magnetism with nanometer spatial resolution. This review will give an introduction into contemporary topics of nanoscale magnetic materials and provide an overview of analytical spectroscopy and microscopy tools based on x-ray dichroism effects. Selected examples of current research will demonstrate the potential and future directions of these techniques. (report on progress)

  10. X-ray examination apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Griswa, P.J.; Halter, P. Jr.; Kidd, H.J.

    1980-01-01

    Apparatus for x-ray cardiovascular examination and which can also be used for general purpose examination is described. An advantage of the system is that there is no mechanical connection between the image intensifier and source to interfere with the medical examiner or emergency procedures. (U.K.)

  11. X-ray tube transformer

    International Nuclear Information System (INIS)

    1980-01-01

    An X-ray generator is described which comprises a transmission line transformer including an electrical conductor with a cavity and a second electrical conductor including helical windings disposed along a longitudinal axis within the cavity of the first conductor. The windings have a pitch which varies per unit length along the axis. There is dielectric material in the cavity for insulation and to couple electromagnetically the two conductors in response to an electric current flowing through the conductors, which have an impedance between them; this varies with distance along the axis of the helix of the second conductor. An X-ray tube is disposed along the longitudinal axis within the cavity, for radiating X-rays. The invention increases the voltage of applied voltage pulses at the remote tube-head with a transformer formed by using a spiral delay line geometry to give a tapered-impedance coaxial high voltage multiplier for pulse voltage operation. This transformer is smaller and lighter than previous designs for the same high peak voltage and power ratings. This is important because the penetration capabilities of Flash X-ray equipment increase with voltage, particularly in heavy materials such as steel. (U.K.)

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of bone cancer . locate foreign objects in soft tissues around or in bones. top of page How should I prepare? Most ... absorb the x-rays in varying degrees. Dense bone absorbs much of the radiation while soft tissue, such as muscle, fat and organs, allow more ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... the equipment look like? How does the procedure work? How is the procedure ... diagnose and treat medical conditions. Imaging with x-rays involves exposing a part ...

  14. Proton exciting X ray analysis

    International Nuclear Information System (INIS)

    Ma Xinpei

    1986-04-01

    The analyzing capability of proton exciting X ray analysis for different elements in organisms was discussed, and dealing with examples of trace element analysis in the human body and animal organisms, such as blood serum, urine, and hair. The sensitivity, accuracy, and capability of multielement analysis were discussed. Its strong points for the trace element analysis in biomedicine were explained

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and easiest ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray ( ...

  17. X-ray absorption holography

    Czech Academy of Sciences Publication Activity Database

    Kopecký, Miloš; Lausi, A.; Bussetto, E.; Kub, Jiří; Savoia, A.

    2002-01-01

    Roč. 88, č. 18 (2002), s. 185503-1 - 185503-3 ISSN 0031-9007 R&D Projects: GA MŠk LN00A100 Institutional research plan: CEZ:AV0Z1010921 Keywords : x-ray holography Subject RIV: BH - Optics, Masers, Lasers Impact factor: 7.323, year: 2002

  18. X-ray Computed Tomography of Ultralightweight Metals

    National Research Council Canada - National Science Library

    Winter, John

    2001-01-01

    .... To date, the imaging capabilities of x-ray computed tomography have not been generally employed to nondestructively examine the internal structure of the products formed by these various processes...

  19. X-ray emission spectroscopy of well-characterised non-LTE plasmas

    International Nuclear Information System (INIS)

    Bourgaux, A C; Bastiani-Ceccotti, S; Audebert, P; Marquès, J R; Vassura, L; Vinci, T; Jacquemot, S; Dorchies, F; Leguay, P M; Chung, H K; Bowen, C; Dervieux, V; Renaudin, P; Silvert, V

    2016-01-01

    This paper will present an experimental platform developed on LULI2000 to measure x-ray emission of non-LTE plasmas in well-defined hydrodynamic conditions thanks to implementation of a whole set of diagnostics, including time-resolved electronic and ionic Thomson scattering and self-optical pyrometry. K-, L- and M-shell spectra will be presented and the methodology, that has been developed to analyze them, discussed. (paper)

  20. X-Ray Optics at NASA Marshall Space Flight Center

    Science.gov (United States)

    O'Dell, Stephen L.; Atkins, Carolyn; Broadway, David M.; Elsner, Ronald F.; Gaskin, Jessica A.; Gubarev, Mikhail V.; Kilaru, Kiranmayee; Kolodziejczak, Jeffery J.; Ramsey, Brian D.; Roche, Jacqueline M.; hide

    2015-01-01

    NASA's Marshall Space Flight Center (MSFC) engages in research, development, design, fabrication, coating, assembly, and testing of grazing-incidence optics (primarily) for x-ray telescope systems. Over the past two decades, MSFC has refined processes for electroformed-nickel replication of grazing-incidence optics, in order to produce high-strength, thin-walled, full-cylinder x-ray mirrors. In recent years, MSFC has used this technology to fabricate numerous x-ray mirror assemblies for several flight (balloon, rocket, and satellite) programs. Additionally, MSFC has demonstrated the suitability of this technology for ground-based laboratory applications-namely, x-ray microscopes and cold-neutron microscopes and concentrators. This mature technology enables the production, at moderately low cost, of reasonably lightweight x-ray telescopes with good (15-30 arcsecond) angular resolution. However, achieving arcsecond imaging for a lightweight x-ray telescope likely requires development of other technologies. Accordingly, MSFC is conducting a multi-faceted research program toward enabling cost-effective production of lightweight high-resolution x-ray mirror assemblies. Relevant research topics currently under investigation include differential deposition for post-fabrication figure correction, in-situ monitoring and control of coating stress, and direct fabrication of thin-walled full-cylinder grazing-incidence mirrors.

  1. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    NARCIS (Netherlands)

    Groot, F.M.F. de

    2000-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption

  2. X-ray fluorescence spectrometry of Al, Mg, Ca, Fe, S in solid phase of magnesite technology of combustion product desulfurization

    International Nuclear Information System (INIS)

    Vymola, R.; Hora, V.; Spitzer, Z.

    1989-01-01

    Solid phase samples of magnesite technology were moulded into pellets or melted into the shape of a glass disk. MgO, CaO, Fe 2 O 3 , S, Al 2 O 3 and SiO 2 were determined in the samples by X-ray fluorescence analysis. Fluorescence intensities were measured with an SRS 200 sequential X-ray spectrometer and the measured data were evaluated using a linked-up PDP 11/04 computer. The reproducibility of MgO, CaO, Fe 2 O 3 and S determinations was very good; higher measurement accuracy was achieved for moulded samples. The specificity of determinations was checked by a comparative chemical analysis. (E.J.). 8 tabs., 5 refs

  3. Semi-empirical and empirical L X-ray production cross sections for elements with 50 ≤ Z ≤ 92 for protons of 0.5-3.0 MeV

    International Nuclear Information System (INIS)

    Nekab, M.; Kahoul, A.

    2006-01-01

    We present in this contribution, semi-empirical production cross sections of the main X-ray lines Lα, Lβ and Lγ for elements from Sn to U and for protons with energies varying from 0.5 to 3.0 MeV. The theoretical X-ray production cross sections are firstly calculated from the theoretical ionization cross sections of the Li (i = 1, 2, 3) subshell within the ECPSSR theory. The semi-empirical Lα, Lβ and Lγ cross sections are then deduced by fitting the available experimental data normalized to their corresponding theoretical values and give the better representation of the experimental data in some cases. On the other hand, the experimental data are directly fitted to deduce the empirical L X-ray production cross sections. A comparison is made between the semi-empirical cross sections, the empirical cross sections reported in this work and the empirical ones reported by Reis and Jesus [M.A. Reis, A.P. Jesus, Atom. Data Nucl. Data Tables 63 (1996) 1] and those of Strivay and Weber [Strivay, G. Weber, Nucl. Instr. and Meth. B 190 (2002) 112

  4. Saturated output tabletop x-ray lasers

    International Nuclear Information System (INIS)

    Dunn, J.; Osterheld, A.L.; Nilsen, J.; Hunter, J.R.; Li, Y.; Faenov, A.Ya.; Pikuz, T.A.; Shlyaptsev, N.

    2000-01-01

    The high efficiency method of transient collisional excitation has been successfully demonstrated for Ne-like and Ni-like ion x-ray laser schemes with small 5-10 J laser facilities. Our recent studies using the tabletop COMET (Compact Multipulse Terawatt) laser system at the Lawrence Livermore National Laboratory (LLNL) have produced several x-ray lasers operating in the saturation regime. Output energy of 10-15 (micro)J corresponding to a gL product of 18 has been achieved on the Ni-like Pd 4d → 4p transition at 147 (angstrom) with a total energy of 5-7 J in a 600 ps pulse followed by a 1.2 ps pulse. Analysis of the laser beam angular profile indicates that refraction plays an important role in the amplification and propagation process in the plasma column. We report further improvement in the extraction efficiency by varying a number of laser driver parameters. In particular, the duration of the second short pulse producing the inversion has an observed effect on the x-ray laser output

  5. Saturated output tabletop X-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, J.; Osterheld, A.L.; Nilsen, J.; Hunter, J.R. [Lawrence Livermore National Lab., CA (United States); Yuelin Li [Lawrence Livermore National Lab., CA (United States); ILSA, Lawrence Livermore National Lab., Livermore, CA (United States); Faenov, A.Ya.; Pikuz, T.A. [Lawrence Livermore National Lab., CA (United States); MISDC of VNIIFTRI, Mendeleevo (Russian Federation); Shlyaptsev, V.N. [Lawrence Livermore National Lab., CA (United States); DAS, Univ. of California Davis-Livermore, Livermore, CA (United States)

    2001-07-01

    The high efficiency method of transient collisional excitation has been successfully demonstrated for Ne-like and Ni-like ion X-ray laser schemes with small 5-10 J laser facilities. Our recent studies using the tabletop COMET (compact multipulse terawatt) laser system at the Lawrence livermore national laboratory (LLNL) have produced several X-ray lasers operating in the saturation regime. Output energy of 10-15 {mu}J corresponding to a gL product of 18 has been achieved on the Ni-like Pd 4d{yields}4p transition at 147 A with a total energy of 5-7 J in a 600 ps pulse followed by a 1.2 ps pulse. Analysis of the laser beam angular profile indicates that refraction plays an important role in the amplification and propagation process in the plasma column. We report further improvement in the extraction efficiency by varying a number of laser driver parameters. In particular, the duration of the second short pulse producing the inversion has an observed effect on the X-ray laser output. (orig.)

  6. Quality criteria for chest X-ray image

    International Nuclear Information System (INIS)

    Krieg, R.

    1985-01-01

    A distinction has to be made between invariable and variable criteria in the determination of chest X-ray picture quality criteria. The invariable criteria are defined by the properties of the object and the psychophysiological laws of perception and cognition, and the variable criteria are determined by the prevailing state of the art of technology. An agreement on these criteria is based on the knowledge of the nature and the technical conditions of X-ray picture production and reproduction. The slogan 'the best picture at the lowest dose' dominates, too, the discussion centering around the X-ray picture of the chest, its quality and criteria. (orig./MG) [de

  7. Soft X-Ray amplification in laser plasmas

    International Nuclear Information System (INIS)

    Louis-Jacquet, M.

    1988-01-01

    The principles, experiments and theoretical models of soft x-ray, amplification, produced in laser plasmas, are studied. In the discussion of the principles, the laser plasma medium, the definition of the gain, the population inversions, saturation and superradiance are described. The results concerning recombination and collisional excitation experiments, as well as experimental devices are shown. A complete physical simulation to design and interpret x-ray laser experiments is given. Applications of x-ray lasers in grating production techniques, in contact microscopy and holography are considered

  8. Medical X-ray techniques in diagnostic radiography. 4. ed.

    International Nuclear Information System (INIS)

    Plaats, G.J. van der; Vijlbrief, P.

    1980-01-01

    A step by step account is given of every aspect of the technical factors involved in the production of X-ray images. Chapter titles include, methods of image formation and laws of projection, sharpness and unsharpness, contrast, perceptibility of detail in the radiographic image-image quality, properties of fluoroscopic screens, radiographic films, intensifying screens and cassettes, image intensification and X-ray television, processing technique, fluoroscopy and radiographic technique in general, special radiographic techniques, radiographic examinations using contrast media, exposure and exposure tables and automatic density control, diagnostic X-ray apparatus, and diagnostic stands and accessories. (C.F.)

  9. Determination of molybdenite leaching degree by x-ray radiometric analysis

    International Nuclear Information System (INIS)

    Bibinov, S.A.; Gladyshev, V.P.; Yarmolik, A.S.; Kim, A.Ch.; Sokur, N.P.

    1984-01-01

    A express chemical X-ray radiometric method for determination of leaching degree and analysis of molybdenite products is developed. The method comprises chemical preparation and the following X-ray radiometric determination of molyb bdenum. Total duration of the analysis is 1-1.5 h. The best reproductivity is btained at X-ray radiometric analysis as compared with the chemical one

  10. Exposure of nitrous oxide to X-rays

    International Nuclear Information System (INIS)

    Yanagida, H.

    1980-01-01

    A study was performed to determine how much NO and NO 2 is produced when nitrous oxide is exposed to X-radiation. Polyethylene bottles filled with either nitrous oxide alone or with nitrous oxide and 30% oxygen were placed 30 cm from the X-ray tube at a standard X-ray beam setting for chest fluoroscopy for 0 to 5 minutes. In the bottles filled with nitrous oxide alone, the production of NO was not affected by the duration of X-ray exposure, but the longer duration of X-ray exposure produced a larger amount of NO 2 . In the bottles filled with nitrous oxide and 30% oxygen, the longer duration of X-ray exposure produced larger amounts of both NO and NO 2 . These findings confirmed a previous investigation in which nitrous oxide was not inert under X-ray exposure. As the presence of oxygen plays an important role in the oxidation of nitrous oxide under X-ray exposure, this study suggests another potentially hazardous interaction that may occur secondary to the administration of an anaesthetic in the presence of X-irradiation as in pulmonary angiography, cardiac catheterisation, and fluoroscopic bronchoscopy or biopsy. (author)

  11. Center for X-Ray Optics, 1986

    International Nuclear Information System (INIS)

    1987-07-01

    The Center for X-Ray Optics has made substantial progress during the past year on the development of very high resolution x-ray technologies, the generation of coherent radiation at x-ray wavelengths, and, based on these new developments, had embarked on several scientific investigations that would not otherwise have been possible. The investigations covered in this report are topics on x-ray sources, x-ray imaging and applications, soft x-ray spectroscopy, synchrotron radiation, advanced light source and magnet structures for undulators and wigglers

  12. X-ray diagnostic in gas discharge

    International Nuclear Information System (INIS)

    Chen Suhe; Wang Dalun; Cui Gaoxian; Wang Mei; Fu Yibei; Zhang Xinwei; Zhang Wushou

    1995-01-01

    X rays were observed when the anomalous phenomenon in the metal loaded with deuterium studied by the gas-discharge method. Therefore the X-ray energy spectra were measured by the absorption method, the specific X-ray approach and the NaI scintillation counter, while X-ray intensity was estimated by using 7 Li thermoluminescent foils. The X-ray average energy measured by the absorption method is 27.6 +- 2.1 keV, which is fitted within the error extent to 26.0 +-2.4 keV monoenergetic X rays measured by the NaI scintillation counter

  13. X-ray cardiovascular examination apparatus

    International Nuclear Information System (INIS)

    1977-01-01

    An X-ray source is mounted in an enclosure for angulating longitudinally about a horizontal axis. An X-ray-permeable, patient-supporting table is mounted on the top of the enclosure for executing lateral and longitudinal movements. An X-ray image-receiving device such as an X-ray image intensifier is mounted above the table on a vertically movable arm which is on a longitudinally movable carriage. Electric control means are provided for angulating the X-ray source and image intensifier synchronously as the image intensifier system is shifted longitudinally or vertically such that the central ray from the X-ray source is kept intensifier

  14. X-ray tube arrangements

    International Nuclear Information System (INIS)

    Gillard, R.G.

    1980-01-01

    A technique for ensuring the rapid correction of both amplitude and offset errors in the deflectional movement of an electron beam along an X-ray emissive target is described. The movement is monitored at at least two positions during a sweep and differences, between the two movements and a desired movement, at these positions are combined in different proportions to produce a corrective servo signal. Such arrangements find application, for example, in computerised tomographic scanners. (author)

  15. Smart X-ray optics

    International Nuclear Information System (INIS)

    Michette, A G; Pfauntsch, S J; Sahraei, S; Shand, M; Morrison, G R; Hart, D; Vojnovic, B; Stevenson, T; Parkes, W; Dunare, C; Willingale, R; Feldman, C; Button, T; Zhang, D; Rodriguez-Sanmartin, D; Wang, H

    2009-01-01

    This paper describes reflective adaptive/active optics for applications including studies of biological radiation damage. The optics work on the polycapillary principle, but use arrays of channels in thin silicon. For optimum performance the x-rays should reflect once off a channel wall in each of two successive arrays. This reduces aberrations since then the Abbe sine condition is approximately satisfied. Adaptivity is achieved by flexing the arrays via piezo actuation, providing further aberration reduction and controllable focal length.

  16. X rays from radio binaries

    International Nuclear Information System (INIS)

    Apparao, K.M.V.

    1977-01-01

    Reference is made to the radio binary systems CC Cas, AR Lac, β Per (Algol), β Lyr, b Per and Cyg X-1. It is stated that a thermal interpretation of the radiation from Algol requires a much larger x-ray flux than the observed value of 3.8 x 10 -11 erg/cm 2 /sec/keV in the 2 to 6 keV energy range. Observations of some non-thermal flares, together with the small size of the radio source in Algol, indicate that the radio emission is non-thermal in nature. The radio emission is interpreted as synchrotron radiation and it is suggested that the observed x-ray emission is due to inverse Compton scattering of the light of the primary star by the radio electrons. The x-ray emission from other radio binaries is also calculated using this model. The energy for the radio electrons can arise from annihilation of magnetic lines connecting the binary stars, twisted by the rotation of the stars. (U.K.)

  17. X-ray area monitor

    International Nuclear Information System (INIS)

    Nintrakit, N.

    1983-01-01

    The X-ray area monitor is a nuclear electronic device that is essential in radiation protection in high radiation laboratories, e.g. in medical diagnosis using X-rays and in industrial X-radiography. Accidentally the level of X-radiator may arise above the safe permissible level and in such a case the alarm system of the area monitor will work and disconnect the ac power supply form the X-ray unit. Principally the device is a radiation counter using G.M.tube as radiation detector with high voltage supply variable form 200 to 2,000 volts. The maximum count rate of the scaler is 1.5 MHz and the total count is displayed on 4 digit LED's. A time base is used to control the counting time, the frequency multiplier, radiation safety limit, comparator and the radiation hazard warning signal. The reliability of the instrument is further enhanced through the addition of the random correction circuit, and it is applicable both in X- and γ -radiation

  18. Radiation processing with high-energy X-rays

    International Nuclear Information System (INIS)

    Cleland, Marshall R.; Stichelbaut, Frederic

    2009-01-01

    The physical, chemical or biological characteristics of selected commercial products and materials can be improved by radiation processing. The ionizing energy can be provided by accelerated electrons with energies between 75 keV and 10 MeV, gamma rays from cobalt-60 with average energies of 1.25 MeV or X-rays with maximum energies up to 7.5 MeV. Electron beams are preferred for thin products, which are processed at high speeds. Gamma rays are used for products that are too thick for treatment with electron beams. High-energy X-rays can also be used for these purposes because their penetration in solid materials is similar to or even slightly greater than that of gamma rays. Previously, the use of X-rays had been inhibited by their slower processing rates and higher costs when compared with gamma rays. Since then, the price of cobalt-60 sources has been increased and the radiation intensity from high-energy, high-power X-ray generators has also increased. For facilities requiring at least 2 MCi of cobalt-60, the capital and operating costs of X-ray facilities with equivalent processing rates can be less than that of gamma-ray irradiators. Several high-energy electron beam facilities have been equipped with removable X-ray targets so that irradiation processes can be done with either type of ionizing energy. A new facility is now being built which will be used exclusively in the X-ray mode to sterilize medical products. Operation of this facility will show that high-energy, high-power X-ray generators are practical alternatives to large gamma-ray sources. (author)

  19. K-shell x-ray production cross sections of selected elements Al to Ni for 4.0 to 38.0 MeV 10B ions

    International Nuclear Information System (INIS)

    Monigold, G.; McDaniel, F.D.; Duggan, J.L.; Mehta, R.; Rice, R.; Miller, P.D.

    1976-01-01

    K-Shell x-ray production cross sections for the target elements Sc, Ti, V, Mn, Fe, Co, and Ni were measured for incident 10 B ions over the energy range 4.0 to 38.0 MeV. The cross section data were compared to the theoretical predictions of the binary encounter approximation (BEA); the plane wave born approximation (PWBA); and the PWBA modified to include corrections for increased binding energy (B), Coulomb deflection of the incident ion (C), orbital perturbation due to polarization (P), and relativistic effects (R). In addition, fluorescence yield variations (W/sub K/) and contributions to the cross sections from electron capture (EC) were included. It was found that the predictions of the fully modified PWBA with contributions from electron capture and fluorescence yield variations included provided the best fit to the experimental data over the entire energy range for each target element. The Kβ/Kα x-ray intensity ratios were compared to theoretical values that assume single hole ionization, and the x-ray energy shifts presented as a function of the energy of the incident ion. These two measurements provided confirmation of the occurrence of multiple ionization for 10 B bombardment of target elements in the range 21 less than or equal to Z 2 less than or equal to 28

  20. Achromatic X-ray lenses

    International Nuclear Information System (INIS)

    Umbach, Marion

    2009-01-01

    This thesis presents first results on the development of achromatic refractive X-ray lenses which can be used for scientific experiments at synchrotron sources. First of all the different requirements for achromatic X-ray lenses have been worked out. There are different types of lenses, one type can be used for monochromatized sources when the energy is scanned while the spot size should be constant. The other type can be used at beamlines providing a broad energy band. By a combination of focusing and defocusing elements we have developed a lens system that strongly reduces the chromatic aberration of a refractive lens in a given energy range. The great challenge in the X-ray case - in contrast to the visible range - the complex refractive index, which is very similar for the possible materials in the X-ray spectrum. For precise studies a numerical code has been developed, which calculates the different rays on their way through the lenses to the detector plane via raytracing. In this numerical code the intensity distribution in the detector plane has been analyzed for a chromatic and the corresponding achromatic system. By optimization routines for the two different fields of applications specific parameter combinations were found. For the experimental verification an achromatic system has been developed, consisting of biconcave SU-8 lenses and biconvex Nickel Fresnel lenses. Their fabrication was based on the LIGA-process, including a further innovative development, namely the fabrication of two different materials on one wafer. In the experiment at the synchrotron source ANKA the energy was varied in a specific energy range in steps of 0.1 keV. The intensity distribution for the different energies was detected at a certain focal length. For the achromatic system a reduction of the chromatic aberration could be clearly shown. Achromatic refractive X-ray lenses, especially for the use at synchrotron sources, have not been developed so far. As a consequence of the

  1. The eROSITA X-ray mirrors: technology and qualification aspects of the production of mandrels, shells and mirror modules

    Science.gov (United States)

    Arcangeli, L.; Borghi, G.; Bräuninger, H.; Citterio, O.; Ferrario, I.; Friedrich, P.; Grisoni, G.; Marioni, F.; Predehl, P.; Rossi, M.; Ritucci, A.; Valsecchi, G.; Vernani, D.

    2017-11-01

    The name "eROSITA" stands for extended Roentgen Survey with an Imaging Telescope Array. The general design of the eROSITA X-ray telescope is derived from that of ABRIXAS. A bundle of 7 mirror modules with short focal lengths make up a compact telescope which is ideal for survey observations. Similar designs had been proposed for the missions DUO and ROSITA but were not realized due to programmatic shortfall. Compared to those, however, the effective area in the soft X-ray band has now much increased by adding 27 additional outer mirror shells to the original 27 ones of each mirror module. The requirement on the on-axis resolution has also been confined, namely to 15 arc seconds HEW. For these reasons the prefix "extended" was added to the original name "ROSITA". The scientific motivation for this extension is founded in the ambitious goal to detect about 100,000 clusters of galaxies which trace the large scale structure of the Universe in space and time. The X-ray telescope of eROSITA will consist of 7 identical and co-aligned mirror modules, each with 54 nested Wolter-1 mirror shells. The mirror shells are glued onto a spider wheel which is screwed to the mirror interface structure making a rigid mechanical unit. The assembly of 7 modules forms a compact hexagonal configuration with 1300 mm diameter (see Fig. 1) and will be attached to the telescope structure which connects to the 7 separate CCD cameras in the focal planes. The co-alignment of the mirror module enables eROSITA to perform also pointed observations. The replication process described in chapter III allows the manufacturing in one single piece and at the same time of both the parabola and hyperbola parts of the Wolter 1 mirror.

  2. Possibility of coherent hard x-ray production by pumping with synchrotron radiation and low energy photons. Period covered: November 17, 1976--August 16, 1977

    International Nuclear Information System (INIS)

    Csonka, P.L.

    1977-01-01

    Coherent x-rays in the keV range could be produced by pumping a suitable gas with synchrotron radiation in combination with low energy photon beams in the presence of appropriately arranged mirrors. With a wiggler magnet placed in the low beta section of the PEP machine to be constructed at Stanford, 1020 eV coherent photons could be produced from Ne. Appropriate synchrotron radiation will produce a highly ionized cool gas. Low energy photons modify the outer electron structure of ions to enhance lasing: they modify the lifetime of the inverted state, counterbalance unwanted collisionally induced transitions, reduce Stark line broadening

  3. Interspecific comparisons of the sensitivity to chromosome aberration production by x rays. [Comparative in vitro radiosensitivity of leukocyte chromosomes from mice to man

    Energy Technology Data Exchange (ETDEWEB)

    Brewen, J.G.

    1978-01-01

    It is concluded that arm number probably plays a minor role, if any, in the relative radiosensitivity of a species. Instead the reported differences are probably a reflection of inherent basic biological mechanisms of repair that vary from one order of mammals to the next. It should be added, however, that the ultimate goal of all of these studies is to make a reasonable risk estimate for man. In that context the best approach is that of conservatism and the current data on mouse and man suggest that man has 1.5 to 2.0 times the risk of mice for chromosome rearrangement induction by x rays.

  4. Effect of different intervals of x-ray split doses on shoot production of in vitro derived explants of Gerbera jamesonii Bolus

    Energy Technology Data Exchange (ETDEWEB)

    Walther, F; Sauer, A [Federal Research Centre for Horticultural Plant Breeding, Ahrensburg (Germany)

    1990-01-01

    Full text: Linearity between rising x-ray doses and mutation rate is limited by the simultaneously increasing radiation damage; induced chromosome aberrations eliminate valuable factor mutations. The application of fractionated doses provides the opportunity for repair of a distinct portion of damage. The dose of 30 Gy was fractionated into two identical parts. The periods for repair were 0.5 to 48 hs. The absolute and cumulative number of post-irradiation regenerated axillary shoots on 4 subsequent dates of cutoff were used as parameters to estimate radiosensitivity. From an economical point of view the interval of 4 hs between two dose fractions may be recommended for practice. (author)

  5. Inhibitor production by normal rat tracheal epithelial cells influences the frequency of spontaneous and X-ray-induced enhanced growth variants

    International Nuclear Information System (INIS)

    Terzaghi-Howe, M.

    1989-01-01

    A cell culture model was used to assay for the induction of cell populations with enhanced growth capacity in culture in irradiated normal rat tracheal epithelial cells (NTEC). Some growth conditions appear to favor the proliferation of both normal and carcinogen-exposed populations, while others appear to select for populations previously exposed to carcinogen. In the present report we focus on what growth conditions are critical for controlling the emergence of spontaneous and X-ray induced proliferating epithelial foci (PEF) and what factor(s) directly influences the relative frequency of PEF in irradiated and control NTEC cultures. (author)

  6. X-ray electromagnetic application technology

    International Nuclear Information System (INIS)

    2011-01-01

    The investigating committee aimed at research on electromagnetic fields in functional devices and X-ray fibers for efficient coherent X-ray generation and their material science, high-precision manufacturing, particularly for X-ray electromagnetic application technology from January 2006 to December 2008. In this report, we describe our research results, in particular, on the topics of synchrotron radiation and free-electron laser, Saga Synchrotron Project, X-ray waveguides and waveguide-based lens-less hard-X-ray imaging, X-ray nanofocusing for capillaries and zone plates, dispersion characteristics in photonics crystal consisting of periodic atoms for nanometer waveguides, electromagnetic characteristics of grid structures for scattering fields of nano-meter electromagnetic waves and X-rays, FDTD parallel computing of fundamental scattering and attenuation characteristics of X-ray for medical imaging diagnosis, orthogonal relations of electromagnetic fields including evanescent field in dispersive medium. (author)

  7. Aspergillosis - chest x-ray (image)

    Science.gov (United States)

    ... usually occurs in immunocompromised individuals. Here, a chest x-ray shows that the fungus has invaded the lung ... are usually seen as black areas on an x-ray. The cloudiness on the left side of this ...

  8. Soft x-ray Planetary Imager

    Data.gov (United States)

    National Aeronautics and Space Administration — The project is to prototype a soft X-ray Imager for planetary applications that has the sensitivity to observe solar system sources of soft  X-ray emission. A strong...

  9. Stabilized x-ray generator power supply

    International Nuclear Information System (INIS)

    Saha, Subimal; Purushotham, K.V.; Bose, S.K.

    1986-01-01

    X-ray diffraction and X-ray fluorescence analysis are very much adopted in laboratories to determine the type and structure of the constituent compounds in solid materials, chemical composition of materials, stress developed on metals etc. These experiments need X-ray beam of fixed intensity and wave length. This can only be achieved by X-ray generator having highly stabilized tube voltage and tube current. This paper describes how X-ray tube high voltage and electron beam current are stabilized. This paper also highlights generation of X-rays, diffractometry and X-ray fluorescence analysis and their wide applications. Principle of operation for stabilizing the X-ray tube voltage and current, different protection circuits adopted, special features of the mains H.V. transformer and H.T. tank are described in this report. (author)

  10. Flexible digital x-ray technology for far-forward remote diagnostic and conformal x-ray imaging applications

    Science.gov (United States)

    Smith, Joseph; Marrs, Michael; Strnad, Mark; Apte, Raj B.; Bert, Julie; Allee, David; Colaneri, Nicholas; Forsythe, Eric; Morton, David

    2013-05-01

    Today's flat panel digital x-ray image sensors, which have been in production since the mid-1990s, are produced exclusively on glass substrates. While acceptable for use in a hospital or doctor's office, conventional glass substrate digital x-ray sensors are too fragile for use outside these controlled environments without extensive reinforcement. Reinforcement, however, significantly increases weight, bulk, and cost, making them impractical for far-forward remote diagnostic applications, which demand rugged and lightweight x-ray detectors. Additionally, glass substrate x-ray detectors are inherently rigid. This limits their use in curved or bendable, conformal x-ray imaging applications such as the non-destructive testing (NDT) of oil pipelines. However, by extending low-temperature thin-film transistor (TFT) technology previously demonstrated on plastic substrate- based electrophoretic and organic light emitting diode (OLED) flexible displays, it is now possible to manufacture durable, lightweight, as well as flexible digital x-ray detectors. In this paper, we discuss the principal technical approaches used to apply flexible display technology to two new large-area flexible digital x-ray sensors for defense, security, and industrial applications and demonstrate their imaging capabilities. Our results include a 4.8″ diagonal, 353 x 463 resolution, flexible digital x-ray detector, fabricated on a 6″ polyethylene naphthalate (PEN) plastic substrate; and a larger, 7.9″ diagonal, 720 x 640 resolution, flexible digital x-ray detector also fabricated on PEN and manufactured on a gen 2 (370 x 470 mm) substrate.

  11. Development of quantitative x-ray microtomography

    International Nuclear Information System (INIS)

    Deckman, H.W.; Dunsmuir, J.A.; D'Amico, K.L.; Ferguson, S.R.; Flannery, B.P.

    1990-01-01

    The authors have developed several x-ray microtomography systems which function as quantitative three dimensional x-ray microscopes. In this paper the authors describe the evolutionary path followed from making the first high resolution experimental microscopes to later generations which can be routinely used for investigating materials. Developing the instrumentation for reliable quantitative x-ray microscopy using synchrotron and laboratory based x-ray sources has led to other imaging modalities for obtaining temporal and spatial two dimensional information

  12. X-ray diagnostics - benefits and risks

    International Nuclear Information System (INIS)

    Bartholomaeus, Melanie

    2016-01-01

    The brochure on benefits and risks of X-ray diagnostics discusses the following issues: X radiation - a pioneering discovery and medical sensation, fundamentals of X radiation, frequency of X-ray examinations in Germany in relation to CT imaging, radiation doses resulting from X-ray diagnostics, benefits of X-ray diagnostics - indication and examples, risks - measures for radiation exposure reductions, avoidance of unnecessary examinations.

  13. Ultrafast secondary emission x-ray imaging detectors

    International Nuclear Information System (INIS)

    Akkerman, A.; Gibrekhterman, A.; Majewski, S.

    1991-07-01

    Fast high accuracy, x-ray imaging at high photon flux can be achieved when coupling thin solid convertors to gaseous electron multipliers, operating at low gas pressures. Secondary electron emitted from the convertor foil are multiplied in several successive amplification elements. The obvious advantage of solid x-ray detectors, as compared to gaseous conversion, are the production of parallax-free images and the fast (subnanoseconds) response. These x-ray detectors have many potential applications in basic and applied research. Of particular interest is the possibility of an efficient and ultrafast high resolution imaging of transition radiation,with a reduced dE/dx background. We present experimental results on the operation of the secondary emission x-ray (SEX) detectors, their detection efficiency, localization and time resolution. The experimental work is accompanied by mathematical modelling and computer simulation of transition radiation detectors based on CsI transition radiation convertors. (author)

  14. Diversity of soft X-ray spectra in quasars

    International Nuclear Information System (INIS)

    Elvis, M.; Wilkes, B.J.; Tananbaum, H.

    1985-01-01

    Soft X-ray spectra for three quasars obtained with the Einstein Imaging Proportional Counter covering the 0.1-4.0 keV band are reported. Power-law fits to these spectra have best-fit energy indices of 1.2 +0.6 or -0.2, for the quasar NAB 0205 + 024, 0.6 +0.3 or -0.2 for the quasar B2 1028 + 313, and 2.2 + or -0.4 for the quasar PG 1211 + 143. None of the quasars shows any evidence for a column density of cold matter in excess of the galactic values. The derived spectra demonstrate that there is no single universal power law slope for quasar X-ray spectra. The implications of these results for the X-ray background, X-ray continuum emission mechanisms, and the production of the optical/UV emission lines are briefly discussed. 46 references

  15. Epoxy replication for Wolter x-ray microscope fabrication

    International Nuclear Information System (INIS)

    Priedhorsky, W.

    1981-01-01

    An epoxy replica of a test piece designed to simulate a Wolter x-ray microscope geometry showed no loss of x-ray reflectivity or resolution, compared to the original. The test piece was a diamond-turned cone with 1.5 0 half angle. A flat was fly-cut on one side, then super- and conventionally polished. The replica was separated at the 1.5 0 -draft angle, simulating a shallow angle Wolter microscope geometry. A test with 8.34 A x rays at 0.9 0 grazing angle showed a reflectivity of 67% for the replica flat surface, and 70% for the original. No spread of the reflected beam was observed with a 20-arc second wide test beam. This test verifies the epoxy replication technique for production of Wolter x-ray microscopes

  16. Cryotomography x-ray microscopy state

    Science.gov (United States)

    Le Gros, Mark; Larabell, Carolyn A.

    2010-10-26

    An x-ray microscope stage enables alignment of a sample about a rotation axis to enable three dimensional tomographic imaging of the sample using an x-ray microscope. A heat exchanger assembly provides cooled gas to a sample during x-ray microscopic imaging.

  17. Transient soft X-ray sources

    International Nuclear Information System (INIS)

    Hayakawa, S.; Murakami, T.; Nagase, F.; Tanaka, Y.; Yamashita, K.

    1976-01-01

    A rocket observation of cosmic soft X-rays suggests the existence of transient, recurrent soft X-ray sources which are found variable during the flight time of the rocket. Some of the soft X-ray sources thus far reported are considered to be of this time. These sources are listed and their positions are shown. (Auth.)

  18. Center for X-ray Optics, 1988

    International Nuclear Information System (INIS)

    1989-04-01

    This report briefly reviews the following topics: soft-x-ray imaging; reflective optics for hard x-rays; coherent XUV sources; spectroscopy with x-rays; detectors for coronary artery imaging; synchrotron-radiation optics; and support for the advanced light source

  19. X-Ray Exam: Femur (Upper Leg)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Femur (Upper Leg) KidsHealth / For Parents / X- ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  20. Automatic weld joint X-ray inspection

    International Nuclear Information System (INIS)

    Richter, H.U.; Linke, D.; Siems, K.D.; Kruse, H.; Schuetze, E.

    1990-01-01

    A gantry mounted robotic x-ray inspection unit has been developed for the series testing of small and medium sized welded components (pipe bends and nozzles). The unit features computer controlled positioning of the x-ray tube and x-ray image amplifier. Image quality classes 2 and even 1 could be achieved without difficulty. (author)

  1. X-ray laser research at Palaiseau

    International Nuclear Information System (INIS)

    Jaegle, P.; Jamelot, G.; Carillon, A.; Klisnick, A.; Paris-11 Univ., 91 - Orsay

    1986-01-01

    We present the soft X-ray laser experiments performed at Greco ''Interaction Laser-Matiere'' (Palaiseau). They are mainly concerned with lithium-like ions of aluminium in plasmas produced by 1.06 μ Nd-laser. We describe the experimental set-up which performs time-dependent gain measurements. We report results showing a gain-length product of 2 - 2.5 for the 3d - 5f line at 105.7 A. Comparison is made between experiment and computational model. The possible limiting role of radiation trapping for long plasma column is discussed. We present the future projects regarding larger gains and new wavelengths

  2. Synchrotron-Radiation Induced X-Ray Emission (SRIXE)

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Keith W.

    1999-09-01

    and increase in scientific use can be maintained for the synchrotron x-ray source. A short summary of the present state of the synchrotron radiation-induced x-ray emission (SRIXE) method is presented here. Basically, SRIXE experiments can include any that depend on the detection. of characteristic x-rays produced by the incident x-ray beam born the synchrotron source as they interact with a sample. Thus, experiments done to measure elemental composition, chemical state, crystal, structure, and other sample parameters can be considered in a discussion of SRIXE. It is also clear that the experimentalist may well wish to use a variety of complementary techniques for study of a given sample. For this reason, discussion of computed microtomography (CMT) and x-ray diffraction is included here. It is hoped that this present discussion will serve as a succinct introduction to the basic ideas of SRIXE for those not working in the field and possibly help to stimulate new types of work by those starting in the field as well as by experienced practitioners of the art. The topics covered include short descriptions of (1) the properties of synchrotron radiation, (2) a description of facilities used for its production, (3) collimated microprobe, (4) focused microprobes, (5) continuum and monoenergetic excitation, (6) detection limits, (7) quantitation, (8) applications of SRIXE, (9) computed microtomography (CMT), and (10)chemical speciation using x-ray absorption near-edge structure (XANES) and extended x-ray absorption fine structure (EXAFS). An effort has been made to cite a wide variety of work from different laboratories to show the vital nature of the field.

  3. Synchrotron-Radiation Induced X-Ray Emission (SRIXE)

    International Nuclear Information System (INIS)

    Jones, Keith W.

    1999-01-01

    and increase in scientific use can be maintained for the synchrotron x-ray source. A short summary of the present state of the synchrotron radiation-induced x-ray emission (SRIXE) method is presented here. Basically, SRIXE experiments can include any that depend on the detection. of characteristic x-rays produced by the incident x-ray beam born the synchrotron source as they interact with a sample. Thus, experiments done to measure elemental composition, chemical state, crystal, structure, and other sample parameters can be considered in a discussion of SRIXE. It is also clear that the experimentalist may well wish to use a variety of complementary techniques for study of a given sample. For this reason, discussion of computed microtomography (CMT) and x-ray diffraction is included here. It is hoped that this present discussion will serve as a succinct introduction to the basic ideas of SRIXE for those not working in the field and possibly help to stimulate new types of work by those starting in the field as well as by experienced practitioners of the art. The topics covered include short descriptions of (1) the properties of synchrotron radiation, (2) a description of facilities used for its production, (3) collimated microprobe, (4) focused microprobes, (5) continuum and monoenergetic excitation, (6) detection limits, (7) quantitation, (8) applications of SRIXE, (9) computed microtomography (CMT), and (10)chemical speciation using x-ray absorption near-edge structure (XANES) and extended x-ray absorption fine structure (EXAFS). An effort has been made to cite a wide variety of work from different laboratories to show the vital nature of the field

  4. Treatment of foods with high-energy X rays

    International Nuclear Information System (INIS)

    Cleland, M.R.; Meissner, J.; Herer, A.S.; Beers, E.W.

    2001-01-01

    The treatment of foods with ionizing energy in the form of gamma rays, accelerated electrons, and X rays can produce beneficial effects, such as inhibiting the sprouting in potatoes, onions, and garlic, controlling insects in fruits, vegetables, and grains, inhibiting the growth of fungi, pasteurizing fresh meat, poultry, and seafood, and sterilizing spices and food additives. After many years of research, these processes have been approved by regulatory authorities in many countries and commercial applications have been increasing. High-energy X rays are especially useful for treating large packages of food. The most attractive features are product penetration, absorbed dose uniformity, high utilization efficiency and short processing time. The ability to energize the X-ray source only when needed enhances the safety and convenience of this technique. The availability of high-energy, high-power electron accelerators, which can be used as X-ray generators, makes it feasible to process large quantities of food economically. Several industrial accelerator facilities already have X-ray conversion equipment and several more will soon be built with product conveying systems designed to take advantage of the unique characteristics of high-energy X rays. These concepts will be reviewed briefly in this paper

  5. Treatment of foods with high-energy X rays

    Science.gov (United States)

    Cleland, M. R.; Meissner, J.; Herer, A. S.; Beers, E. W.

    2001-07-01

    The treatment of foods with ionizing energy in the form of gamma rays, accelerated electrons, and X rays can produce beneficial effects, such as inhibiting the sprouting in potatoes, onions, and garlic, controlling insects in fruits, vegetables, and grains, inhibiting the growth of fungi, pasteurizing fresh meat, poultry, and seafood, and sterilizing spices and food additives. After many years of research, these processes have been approved by regulatory authorities in many countries and commercial applications have been increasing. High-energy X rays are especially useful for treating large packages of food. The most attractive features are product penetration, absorbed dose uniformity, high utilization efficiency and short processing time. The ability to energize the X-ray source only when needed enhances the safety and convenience of this technique. The availability of high-energy, high-power electron accelerators, which can be used as X-ray generators, makes it feasible to process large quantities of food economically. Several industrial accelerator facilities already have X-ray conversion equipment and several more will soon be built with product conveying systems designed to take advantage of the unique characteristics of high-energy X rays. These concepts will be reviewed briefly in this paper.

  6. X-ray trace element analysis with positive ion beams

    International Nuclear Information System (INIS)

    Davis, R.H.

    1973-01-01

    A new trace element analysis having the advantage that many elements may be detected in a single measurement, based on positive charged particle induced X-ray florescence and on the production of X-rays by heavy ions, is described. Because of the large cross-sections for the production of discrete X-ray and the low yield of continuum radiation, positive charged particle X-ray florescence is a competitive, fast, analytic tool. In the experiment a beam of positive charged particles from an accelerator was directed toward a target. X-rays induced by the bombardment were detected by a Si(Li) detector the ouput from which was amplified and sorted in a multichannel analyzer. For rapid data handling and analysis, the multichannel analyzer or ADC unit was connected to an on-line computer. A large variety of targets prepared in collaboration with the oceanographers have been studied and spectra obtained for different particles having the same velocity are presented to show that the yield of discrete X-rays increases at least as rapidly as Z 2 . While protons of several MeV appear to be already competitive further advantage may be gained by heavy ions at lower energies since the continuum is reduced while the peak ''signals'' retain strength due to the Z 2 dependence. (S.B.)

  7. X-ray photographic apparatus

    International Nuclear Information System (INIS)

    1977-01-01

    The X-ray photographic system is designed for medical applications. Two detectors are used for surveys in different planes, and produce electrical signals which are supplied to a comparator. The electron beams are examined according to a system of reference time steps. The apparatus includes a light source and a photo-detector and enables a reference signal to be produced against which the detected signals are compared. The beam source is formed from an electron gun, an extractor electrode and an anode; beam then passes through a collimator. (G.C.)

  8. X-ray source array

    International Nuclear Information System (INIS)

    Cooperstein, G.; Lanza, R.C.; Sohval, A.R.

    1983-01-01

    A circular array of cold cathode diode X-ray sources, for radiation imaging applications, such as computed tomography includes electrically conductive cathode plates each of which cooperates with at least two anodes to form at least two diode sources. In one arrangement, two annular cathodes are separated by radially extending, rod-like anodes. Field enhancement blades may be provided on the cathodes. In an alternative arrangement, the cathode plates extend radially and each pair is separated by an anode plate also extending radially. (author)

  9. X-ray intensifying screens

    International Nuclear Information System (INIS)

    Bossomaier, T.R.J.; Sangway, P.C.

    1979-01-01

    It is claimed that stabilization of X-ray intensifying screens against discolouration and hydrolysis of lanthanum or gadolinium oxyhalide phosphors can be achieved by incorporating into the phosphor/binder formulation a compound containing free epoxy groups. Suitable epoxy compounds include gamma glycidoxy trimethoxy silane and dimethyl di(m-glycidoxy methylphenyl) methane. The oxyhalide may be activated by Tb, Tm or Yb and may be mixed with other phosphors. Plasticisers and organo-tin stabilisers for the formulation are given. Many binders are specified, preferably these should not react with the free epoxy groups. (UK)

  10. Protonium X-ray spectroscopy

    CERN Document Server

    Gotta, D

    1999-01-01

    The Lyman and Balmer transitions from antiprotonic hydrogen and deuterium were studied extensively at the low-energy-antiproton ring LEAR at CERN in order to determine the strong interaction effects. A first series of experiments $9 was performed with semiconductor and gaseous X-ray detectors. In the last years of LEAR operation using a Bragg crystal spectrometer, strong interaction parameters in the 2p states of antiprotonic hydrogen and deuterium were measured $9 directly. The results of the measurements support the meson-exchange models describing the medium and long range part of the nucleon-antinucleon interaction. (39 refs).

  11. X-ray calibration qualities

    International Nuclear Information System (INIS)

    Burns, J.E.

    1998-01-01

    Since the recent publication of IAEA Technical Reports Series No. 374 ''Calibration of Dosimeters Used in Radiotheraphy'', there have been a number of queries about the origin of, and the rationale behind, the X-ray qualities recommended for calibration purposes. The simple answer is that these are the qualities derived at the UK National Physical Laboratory (NPL) in 1971 for calibration of therapy-level dosimeters and which are still in use for that purpose. As some SSDLs may have difficulties in adopting these exact combinations of kV and filtration. This paper discusses the basic ideas involved, and how to go about deriving a different series of qualities

  12. NIKOLA TESLA AND THE X-RAY

    OpenAIRE

    Rade R. Babic

    2005-01-01

    After professor Wilhelm Konrad Röntgen published his study of an x-ray discovery (Academy Bulletin, Berlin, 08. 11. 1895.), Nikola Tesla published his first study of an x-ray on the 11th of March in 1896. (X-ray, Electrical Review). Until the 11th of August in 1897 he had published ten studies on this subject. All Tesla,s x-ray studies were experimental, which is specific to his work. Studying the nature of the x-ray, he established a new medical branch-radiology. He wrote:” There’s no doubt...

  13. Einstein pictures the x-ray sky

    International Nuclear Information System (INIS)

    Hartline, B.K.

    1979-01-01

    The second High Energy Astronomy Observatory (HEAO-2, Einstein) is revolutionizing x-ray astronomy just as its namesake revolutionized physics. Earlier x-ray observatories, including HEAO-1, were designed to scan the sky for x-ray emitters. With Einstein, the challenge has shifted from discovering x-ray sources to understanding the processes producing the x-rays. But having 500 times the sensitivity of previous detectors, Einstein makes more than its share of discoveries, too. For example, it sees distant quasars and clusters of galaxies that can barely be detected by the largest optical telescopes

  14. Picosecond x-ray streak camera studies

    International Nuclear Information System (INIS)

    Kasyanov, Yu.S.; Malyutin, A.A.; Richardson, M.C.; Chevokin, V.K.

    1975-01-01

    Some initial results of direct measurement of picosecond x-ray emission from laser-produced plasmas are presented. A PIM-UMI 93 image converter tube, incorporating an x-ray sensitive photocathode, linear deflection, and three stages of image amplification was used to analyse the x-ray radiation emanating from plasmas produced from solid Ti targets by single high-intensity picosecond laser pulses. From such plasmas, the x-ray emission typically persisted for times of 60psec. However, it is shown that this detection system should be capable of resolving x-ray phenomena of much shorter duration. (author)

  15. Si(Li) X-ray detector

    International Nuclear Information System (INIS)

    Yuan Xianglin; Li Zhiyong; Hong Xiuse

    1990-08-01

    The fabrication technology of the 10∼80 mm 2 Si(Li) X-ray detectors are described and some problems concerning technology and measurement are discussed. The specifications of the detectors are shown as well. The Si(Li) X-ray detector is a kind of low energy X-ray detectors. Owing to very high energy resolution, fine linearity and high detection efficiency in the range of low energy X-rays, it is widely used in the fields of nuclear physics, medicine, geology and environmental protection, etc,. It is also a kernel component for the scanning electron microscope and X-ray fluorescence analysis systems

  16. X-Ray-Driven Gamma Emission

    International Nuclear Information System (INIS)

    Carroll, J. J.; Karamian, S. A.; Rivlin, L. A.; Zadernovsky, A. A.

    2001-01-01

    X-ray-driven gamma emission describes processes that may release nuclear energy in a 'clean' way, as bursts of incoherent or coherent gamma rays without the production of radioactive by-products. Over the past decade, studies in this area, as a part of the larger field of quantum nucleonics, have gained tremendous momentum. Since 1987 it has been established that photons could trigger gamma emission from a long-lived metastable nuclear excited state of one nuclide and it appears likely that triggering in other isotopes will be demonstrated conclusively in the near future. With these experimental results have come new proposals for the creation of collective and avalanche-like incoherent gamma-ray bursts and even for the ultimate light source, a gamma-ray laser. Obviously, many applications would benefit from controlled bursts of gamma radiation, whether coherent or not. This paper reviews the experimental results and concepts for the production of gamma rays, driven by externally produced X-rays

  17. New Rhodotron and X-ray applications

    International Nuclear Information System (INIS)

    Morel, F.

    1991-01-01

    Food processing application possibilities seemed to have come to a virtual standstill. Obstacles to further development, of course, were: -legislation, - industrial strategy, - psychological refusal on the part of consumers of ionized foods. And suddenly, Legislation, not unlike that in the UK, takes a modern view of matters, CEA launches its Rhodotron late 1990, and Aerial publishes its work on X-rays. A breakthrough. The article below is a roundup of recent developments in the field of food processing ionization, both as regards technology and applications. Major inventions are: (1) CEA's new industrial electron accelerator. This compact, simple and economical unit is perfectly suited for production line operations and, (2) a high-penetration, high-conversion X-ray method squaling Cobalt 6 penetration. Legislation, however, is one of the factors that will determine the ionization market's development. Laws are more or less restrictive depending upon country. Two-tier legislation is an often-heard expression. Talks slated for the second half of this year at Brussels might clear matters up somewhat. Marketing-wise, the absence of references for products requiring long development lead times is a major obstacle to sales. Dry and deep-frozen product problems, though, have been practically solved

  18. Phase-contrast X-ray imaging using an X-ray interferometer for biological imaging

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi; Koyama, Ichiro [Tokyo Univ., Dept. of Applied Physics, Tokyo (Japan); Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Inst. of Clinical Medicine, Tsukuba, Ibaraki (Japan); Yoneyama, Akio [Hitachi Ltd., Advanced Research Laboratory, Saitama (Japan)

    2002-04-01

    The potential of phase-contrast X-ray imaging using an X-ray interferometer is discussed comparing with other phase-contrast X-ray imaging methods, and its principle of contrast generation is presented including the case of phase-contrast X-ray computed tomography. The status of current instrumentation is described and perspectives for practical applications are discussed. (author)

  19. Method for spatially modulating X-ray pulses using MEMS-based X-ray optics

    Science.gov (United States)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2015-03-10

    A method and apparatus are provided for spatially modulating X-rays or X-ray pulses using microelectromechanical systems (MEMS) based X-ray optics. A torsionally-oscillating MEMS micromirror and a method of leveraging the grazing-angle reflection property are provided to modulate X-ray pulses with a high-degree of controllability.

  20. X-ray geometrical smoothing effect in indirect x-ray-drive implosion

    International Nuclear Information System (INIS)

    Mochizuki, Takayasu; Sakabe, Shuji; Yamanaka, Chiyoe

    1983-01-01

    X-ray geometrical smoothing effect in indirect X-ray drive pellet implosion for inertial confinement fusion has been numerically analyzed. Attainable X-ray driven ablation pressure has been found to be coupled with X-ray irradiation uniformity. (author)