WorldWideScience

Sample records for m-conversion coefficient

  1. Analysis of internal conversion coefficients

    International Nuclear Information System (INIS)

    Coursol, N.; Gorozhankin, V.M.; Yakushev, E.A.; Briancon, C.; Vylov, Ts.

    2000-01-01

    An extensive database has been assembled that contains the three most widely used sets of calculated internal conversion coefficients (ICC): [Hager R.S., Seltzer E.C., 1968. Internal conversion tables. K-, L-, M-shell Conversion coefficients for Z=30 to Z=103, Nucl. Data Tables A4, 1-237; Band I.M., Trzhaskovskaya M.B., 1978. Tables of gamma-ray internal conversion coefficients for the K-, L- and M-shells, 10≤Z≤104, Special Report of Leningrad Nuclear Physics Institute; Roesel F., Fries H.M., Alder K., Pauli H.C., 1978. Internal conversion coefficients for all atomic shells, At. Data Nucl. Data Tables 21, 91-289] and also includes new Dirac-Fock calculations [Band I.M. and Trzhaskovskaya M.B., 1993. Internal conversion coefficients for low-energy nuclear transitions, At. Data Nucl. Data Tables 55, 43-61]. This database is linked to a computer program to plot ICCs and their combinations (sums and ratios) as a function of Z and energy, as well as relative deviations of ICC or their combinations for any pair of tabulated data. Examples of these analyses are presented for the K-shell and total ICCs of the gamma-ray standards [Hansen H.H., 1985. Evaluation of K-shell and total internal conversion coefficients for some selected nuclear transitions, Eur. Appl. Res. Rept. Nucl. Sci. Tech. 11.6 (4) 777-816] and for the K-shell and total ICCs of high multipolarity transitions (total, K-, L-, M-shells of E3 and M3 and K-shell of M4). Experimental data sets are also compared with the theoretical values of these specific calculations

  2. Theoretical expression of the internal conversion coefficient of a M1 transition between two atomic states

    International Nuclear Information System (INIS)

    Attallah, F.; Chemin, J.F.; Scheurer, J.N.; Karpeshin, F.; Harston, M.

    1997-01-01

    We have established a general relation for the expression of the internal conversion of an M 1 transition a 1s electronic state to an empty ns electronic bound state. Under the hypothesis that the density of the electron level ρ n satisfies the condition ρ n Γ >> 1 (where Γ is the total width of the excited atomic state) a calculation in the first order gives a relation for the internal conversion coefficient.This relation shows that the internal conversion coefficient takes a resonant character when the nuclear energy transition is smaller than the binding energy of the 1s electron. An application of this relation to an M 1 transition in the case of the ion 125 T e with a charge state Q = 45 and an 1s electron binding energy E B 45 = 35.581 KeV gives the value for the internal conversion coefficient R = 5.7

  3. Measurement of K-conversion coefficient of the M3 transition in sup 112 In sup m

    Energy Technology Data Exchange (ETDEWEB)

    Krishna, K.R.; Sastry, D.L.; Reddy, K.V. (Andhra Univ., Visakhapatnam (India). Labs. for Nuclear Research); Chintalapudi, S.N. (Variable Energy Cyclotron Centre, Calcutta (India))

    1991-11-01

    The K-conversion coefficient of the 155 keV (M3) isomeric transition in the decay of {sup 112}In was measured using the normalized peak to gamma method. The {alpha}{sub K} value is found to be 4.82{+-}0.29 in agreement with the theoretical value of 5.12. (author).

  4. Local organ dose conversion coefficients for angiographic examinations of coronary arteries

    International Nuclear Information System (INIS)

    Schlattl, H; Zankl, M; Hausleiter, J; Hoeschen, C

    2007-01-01

    New organ dose conversion coefficients for coronary angiographic interventions are presented, as well as dose distributions and resulting maximal local dose conversion coefficients in the relevant organs. For the Monte Carlo based simulations, voxel models of the human anatomy were employed which represent the average Caucasian adult man and woman as defined by the International Commission on Radiological Protection. In the 21 investigated projections, the mean organ dose conversion coefficients vary from a few 0.01 to 2 mGy(Gy cm 2 ) -1 , depending on the projections. However, especially in portions of the lungs and the active bone marrow, the conversion coefficients can locally amount up to 10 mGy(Gy cm 2 ) -1 , which is half the average conversion coefficient of the skin at the field entrance. In addition to the dose conversion coefficients, the dependence of the patient dose on the projection has been estimated. It could be shown that the patient doses are highest for left anterior oblique views with strong caudal or cranial orientation. Nevertheless, for a large range of image-intensifier positions no significant dose differences could be found

  5. Graphical comparison of calculated internal conversion coefficients

    International Nuclear Information System (INIS)

    Ewbank, W.B.

    1980-11-01

    Calculated values of the coefficients of internal conversion of gamma rays in the K shell and L 1 , L 2 , L 3 subshells from published tabulations by Band and Trzhaskovskaya and by Roesel et al. at Data Nucl. Data Tables, 21, 92-514(1978) are compared with values obtained by computer interpolation among tabulated values of Hager and Seltzer Nucl. Data, A4, 1-235(1968). In some cases, agreement among the three calculations is remarkably good, and differences are generally less than 5%. In a few cases, there are differences as large as 20 to 50%, corresponding to the threshold effect described by Roesel et al. The Z-dependent resonance minimum described by Roesel et al. is also observed in the comparison of E1-E4 conversion in the L 1 subshell. In several cases (notably M1-M4 conversion in the K shell and L 1 subshell), the Band and Roesel calculations show dramatically different dependence on gamma energy and atomic number. For Z = 100, the Band calculation for E4 conversion in the L 3 subshell shows irregular behavior at energies below the K-shell binding energy. A few high-quality measurements of internal conversion coefficients (+-5%) would help greatly to establish a basis for choice among the theoretical calculations. 32 figures

  6. Determination of the absolute K through O conversion coefficients of the 80-keV M4 transition in /sup 193/Ir/sup m/

    International Nuclear Information System (INIS)

    Lindner, M.; Gunnink, R.; Nagle, R.J.

    1987-01-01

    We produced carrier-free, nearly isotopically pure /sup 193/Ir/sup m/ from thermal-neutron irradiation of /sup 192/Os. From studies of the conversion-electron spectrum, the photon spectrum, and the absolute counting rates, we determined the absolute K, L1, L2, L3, M1, M3, M5, N, and O+P conversion coefficients for the first time. With possibly one exception, these values agree closely with theoretical calculations. The value for the energy of the unconverted gamma ray was found to be 80.22 +- 0.02 keV. The half-life for /sup 193/Ir/sup m/ determined by absolute electron counting in a proportional counter of 100% counting efficiency (4πβ) was found to be 10.53 +- 0.04 d. We have determined the L 1 subshell fluorescence yield, ω 1 , to be 0.120 +- 0.003 for iridium. Based upon our measurements of initial and final L subshell vacancies together with a best-fit literature value for ω 2 , we have found a plausible value for the Coster-Kronig coefficient f/sub 12/ to be 0.091 +- 0.011

  7. Experimental techniques of conversion coefficient measurements

    International Nuclear Information System (INIS)

    Hamilton, J.H.

    1975-01-01

    Discusses briefly the history of conversion electron spectra measurements, and the interpretation of the collected data. Then provides a comprehensive review of techniques presently available to measure the conversion coefficients. (Auth.)

  8. Calculation of conversion coefficients for clinical photon spectra using the MCNP code.

    Science.gov (United States)

    Lima, M A F; Silva, A X; Crispim, V R

    2004-01-01

    In this work, the MCNP4B code has been employed to calculate conversion coefficients from air kerma to the ambient dose equivalent, H*(10)/Ka, for monoenergetic photon energies from 10 keV to 50 MeV, assuming the kerma approximation. Also estimated are the H*(10)/Ka for photon beams produced by linear accelerators, such as Clinac-4 and Clinac-2500, after transmission through primary barriers of radiotherapy treatment rooms. The results for the conversion coefficients for monoenergetic photon energies, with statistical uncertainty <2%, are compared with those in ICRP publication 74 and good agreements were obtained. The conversion coefficients calculated for real clinic spectra transmitted through walls of concrete of 1, 1.5 and 2 m thick, are in the range of 1.06-1.12 Sv Gy(-1).

  9. Internal conversion coefficients of M4 isomeric transitions in /sup 125/ /sup 127/ /sup 129/Te decay

    Energy Technology Data Exchange (ETDEWEB)

    Soni, S K; Kumar, A; Gupta, S L; Pancholi, S C [Delhi Univ. (India). Dept. of Physics and Astrophysics

    1977-01-01

    The internal conversion coefficients have been measured using a high resolution low energy Ge(Li) detector for the following M4 transitions: /sup 125/Te: 109.27 keV transition ..cap alpha..sub(T) = 357 +- 11; RG method, /sup 127/Te: 88,26 keV transition ..cap alpha..sub(K) = 484 +- 23; XPG method, /sup 129/Te: 105.50 keV transition ..cap alpha..sub(K) = 213 +- 10; XPG method. It is observed that these values are lower by 2.5-3.6% as compared with Hager and Seltzer's calculations. A comparison between experimental and theoretical ..cap alpha..sub(K) and ..cap alpha..sub(T) values for eleven M4 transitions shows that the experimental values are systematically lower.

  10. Conversion coefficients and yrast state spins in 180Os

    International Nuclear Information System (INIS)

    Dracoulis, G.D.; Kibedi, T.; Byrne, A.P.; Fabricius, B.; Stuchbery, A.E.

    1989-11-01

    Internal conversion coefficients of transitions in 180 Os have been measured using a superconducting, solenoidal electron spectrometer, operated in the lens mode. The high energy resolution and efficiency allow a precise measurement of the conversion coefficients of the 528 keV yrast transition. The values obtained, α K = 0.015 (2), α L = 0.004(1) define pure E2 multipolarity. Taken with the measured γ-ray angular distribution, the conversion coefficient leads to an unambiguous assignment of 16 + →14 + for the 528 keV transition. 14 refs., 5 figs., 1 tab

  11. How good are the internal conversion coefficients now?

    International Nuclear Information System (INIS)

    Raman, S.; Nestor, C.W. Jr.; Ichihara, A.; Trzhaskovskaya, M.B.

    2002-01-01

    To fully utilize experimental internal conversion coefficients, one needs a reliable calculation of theoretical values. We have assembled a set of 100 experimental conversion coefficients, 45 α K and 55 α T values, measured with an accuracy of better than 5%, and generated the corresponding theoretical values using two methods, relativistic Hartree-Fock-Slater (RHFS) and relativistic Dirac-Fock (DF). Extensive comparisons of the experimental values with the two sets of theoretical values show that the DF method is clearly superior to the RHFS method in the overall reproduction of the experimental internal conversion coefficients. We discuss in some detail the differences between various versions of these two theoretical approaches, with a view to understanding which of these differences are most critical to obtaining agreement with experiment

  12. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Sorri, J., E-mail: juha.m.t.sorri@jyu.fi [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Greenlees, P.T.; Papadakis, P.; Konki, J. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Cox, D.M. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Herzberg, R.-D. [Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Smallcombe, J.; Davies, P.J.; Barton, C.J.; Jenkins, D.G. [Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom)

    2016-03-11

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of {sup 154}Sm, {sup 152}Sm and {sup 166}Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  13. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    International Nuclear Information System (INIS)

    Sorri, J.; Greenlees, P.T.; Papadakis, P.; Konki, J.; Cox, D.M.; Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J.; Herzberg, R.-D.; Smallcombe, J.; Davies, P.J.; Barton, C.J.; Jenkins, D.G.

    2016-01-01

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of "1"5"4Sm, "1"5"2Sm and "1"6"6Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  14. Absorbed dose conversion coefficients for embryo and foetus in neutron fields

    International Nuclear Information System (INIS)

    Chen, J.

    2007-01-01

    The Monte Carlo code MCNPX has been used to determine mean absorbed doses to the embryo and foetus when the mother is exposed to neutron fields. There are situations, such as on-board aircraft, where high-energy neutrons are often peaked in top down (TOP) direction. In addition to previous publications for standard irradiation geometries, this study provides absorbed dose conversion coefficients for the embryo of 8 weeks and the foetus of 3, 6 or 9 months at TOP irradiation geometry. The conversion coefficients are compared with the coefficients in isotropic irradiation (ISO). With increasing neutron energies, the conversion coefficients in TOP irradiation become dominant. A set of conversion coefficients is constructed from the higher value in either ISO or TOP irradiation at a given neutron energy. In cases where the irradiation geometry is not adequately known, this set of conversion coefficients can be used in a conservative dose assessment for embryo and foetus in neutron fields. (authors)

  15. Personal dose equivalent conversion coefficients for electrons to 1 Ge V.

    Science.gov (United States)

    Veinot, K G; Hertel, N E

    2012-04-01

    In a previous paper, conversion coefficients for the personal dose equivalent, H(p)(d), for photons were reported. This note reports values for electrons calculated using similar techniques. The personal dose equivalent is the quantity used to approximate the protection quantity effective dose when performing personal dosemeter calibrations and in practice the personal dose equivalent is determined using a 30×30×15 cm slab-type phantom. Conversion coefficients to 1 GeV have been calculated for H(p)(10), H(p)(3) and H(p)(0.07) in the recommended slab phantom. Although the conversion coefficients were determined for discrete incident energies, analytical fits of the conversion coefficients over the energy range are provided using a similar formulation as in the photon results previously reported. The conversion coefficients for the personal dose equivalent are compared with the appropriate protection quantity, calculated according to the recommendations of the latest International Commission on Radiological Protection guidance. Effects of eyewear on H(p)(3) are also discussed.

  16. Absorbed Internal Dose Conversion Coefficients for Domestic Reference Animals and Plant

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Choi, Yong Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-02-15

    This paper describes the methodology of calculating the internal dose conversion coefficient in order to assess the radiological impact on non-human species. This paper also presents the internal dose conversion coefficients of 25 radionuclides ({sup 3}H, {sup 7}Be, {sup 14}C, {sup 40}K, {sup 51}Cr, {sup 54}Mn, {sup 59}Fe, {sup 58}Co, {sup 60}Co, {sup 65}Zn, {sup 90}Sr, '9{sup 5}Zr, {sup 95}Nb, {sup 99}Tc, {sup 106}Ru, {sup 129}I, {sup 131}I, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La, {sup 144}Ce, {sup 238}U, {sup 239}Pu, {sup 240}Pu) for domestic seven reference animals (roe deer, rat, frog, snake, Chinese minnow, bee, and earthworm) and one reference plant (pine tree). The uniform isotropic model was applied in order to calculate the internal dose conversion coefficients. The calculated internal dose conversion coefficient (muGyd{sup -1} per Bqkg{sup -1}) ranged from 10{sup -6} to 10{sup -2} according to the type of radionuclides and organisms studied. It turns out that the internal does conversion coefficient was higher for alpha radionuclides, such as {sup 238}U, {sup 239}Pu, and {sup 240}Pu, and for large organisms, such as roe deer and pine tree. The internal dose conversion coefficients of {sup 239}Pu, {sup 240}Pu, {sup 238}U, {sup 14}C, {sup 3}H and {sup 99}Tc were independent of the organism

  17. Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation

    International Nuclear Information System (INIS)

    Schlattl, H; Zankl, M; Becker, J; Hoeschen, C

    2012-01-01

    A common dose-saving technique used in modern CT devices is automatic tube current modulation (TCM), which was originally designed to also reduce the dose in paediatric CT patients. In order to be able to deduce detailed organ doses of paediatric models, dose conversion coefficients normalized to CTDI vol for an eight-week-old baby and seven- and eight-year-old children have been computed accounting for TCM. The relative difference in organ dose conversion coefficients with and without TCM is for many organs and examinations less than 10%, but can in some cases amount up to 30%, e.g., for the thyroid in the chest CT of the seven-year-old child. Overall, the impact of TCM on the conversion coefficients increases with increasing age. Besides TCM, also the effect of collimation and tube voltage on organ dose conversion coefficients has been investigated. It could be shown that the normalization to CTDI vol leads to conversion coefficients that can in most cases be considered to be independent of collimation and tube voltage. (paper)

  18. Total internal conversion coefficient of the 260. 9 keV (7/sup +/->3/sup -/) transition in sup(198m)Tl

    Energy Technology Data Exchange (ETDEWEB)

    Venkateswara Rao, N.; Suryanarayana, C.; Narayana, D.G.S.; Bhuloka Reddy, S.; Satynarayana, G.; Sastry, D.L.; Chintalapudi, S.N.

    1986-02-21

    The 1.87 hours 543.7 keV (7/sup +/) isomeric state in /sup 198/Tl is produced via /sup 197/Au(..cap alpha.., 3n)sup(198m)Tl (Esub(..cap alpha..) = 35 MeV) reaction. The total conversion coefficient of 260.9 keV (7/sup +/ -> 3/sup -/) is determined for the first time by the intensity balance method. The value of ..cap alpha..sub(T)(260.9 keV) is found to be 40.1 +- 8.6 which is in good agreement with the theoretical value of Hager and Seltzer for pure M4 transition. The gamma transition probability of the 260.9 keV (M4) is calculated using the present value of ..cap alpha..sub(T) and compared with the single-particle estimate.

  19. Conversion coefficients for determining organ doses in paediatric spine radiography

    Energy Technology Data Exchange (ETDEWEB)

    Seidenbusch, Michael; Schneider, Karl [Ludwig-Maximilians-University of Munich, Institute of Clinical Radiology - Paediatric Radiology, Muenchen (Germany)

    2014-04-15

    Knowledge of organ and effective doses achieved during paediatric x-ray examinations is an important prerequisite for assessment of radiation burden to the patient. Conversion coefficients for reconstruction of organ and effective doses from entrance doses for segmental spine radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients are provided regarding the Guidelines of Good Radiographic Technique of the European Commission. Using the personal computer program PCXMC developed by the Finnish Centre for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional segmental spine radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation field settings. Conversion coefficients for the reconstruction of organ doses in about 40 organs and tissues from measured entrance doses during cervical, thoracic and lumbar spine radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients were calculated for the standard sagittal and lateral beam projections and the standard focus detector distance of 115 cm. The conversion coefficients presented may be used for organ dose assessments from entrance doses measured during spine radiographs of patients of all age groups and all field settings within the optimal and suboptimal standard field settings. (orig.)

  20. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    International Nuclear Information System (INIS)

    Sakamoto, Yukio

    2005-01-01

    Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of these data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality factors to consider the consistency between radiation weighting factors and Q-L relationship. The effective dose conversion coefficients obtained in this work were in good agreement with those recently evaluated by using FLUKA code for photons and electrons with all energies, and neutrons and protons below 500 MeV. There were some discrepancy between two data owing to the difference of cross sections in the nuclear reaction models. The dose conversion coefficients of effective dose equivalents for high energy radiations based on Q-L relation in ICRP Publication 60 were evaluated only in this work. The previous comparison between effective dose and effective dose equivalent made it clear that the radiation weighting factors for high energy neutrons and protons were overestimated and the modification was required. (author)

  1. Neutron fluence-to-dose conversion coefficients for embryo and fetus

    International Nuclear Information System (INIS)

    Chen, J.; Meyerhof, D.; Vlahovich, S.

    2004-01-01

    A problem of concern in radiation protection is the exposure of pregnant women to ionising radiation, because of the high radiosensitivity of the embryo and fetus. External neutron exposure is of concern when pregnant women travel by aeroplane. Dose assessments for neutrons frequently rely on fluence-to-dose conversion coefficients. While neutron fluence-to-dose conversion coefficients for adults are recommended in International Commission on Radiological Protection publications and International Commission on Radiological Units and Measurements reports, conversion coefficients for embryos and fetuses are not given in the publications. This study undertakes Monte Carlo calculations to determine the mean absorbed doses to the embryo and fetus when the mother is exposed to neutron fields. A new set of mathematical models for the embryo and fetus has been developed at Health Canada and is used together with mathematical phantoms of a pregnant female developed at Oak Ridge National Laboratory. Monoenergetic neutrons from 1 eV to 10 MeV are considered in this study. The irradiation geometries include antero-posterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT) and isotropic (ISO) geometries. At each of these standard irradiation geometries, absorbed doses to the fetal brain and body are calculated; for the embryo at 8 weeks and the fetus at 3, 6 or 9 months. Neutron fluence-to-absorbed dose conversion coefficients are derived for the four age groups. Neutron fluence-to-equivalent dose conversion coefficients are given for the AP irradiations which yield the highest radiation dose to the fetal body in the neutron energy range considered here. The results indicate that for neutrons <10 MeV more protection should be given to pregnant women in the first trimester due to the higher absorbed dose per unit neutron fluence to the fetus. (authors)

  2. Neutron fluence-to-dose conversion coefficients for embryo and fetus.

    Science.gov (United States)

    Chen, Jing; Meyerhof, Dorothy; Vlahovich, Slavica

    2004-01-01

    A problem of concern in radiation protection is the exposure of pregnant women to ionising radiation, because of the high radiosensitivity of the embryo and fetus. External neutron exposure is of concern when pregnant women travel by aeroplane. Dose assessments for neutrons frequently rely on fluence-to-dose conversion coefficients. While neutron fluence-to-dose conversion coefficients for adults are recommended in International Commission on Radiological Protection publications and International Commission on Radiological Units and Measurements reports, conversion coefficients for embryos and fetuses are not given in the publications. This study undertakes Monte Carlo calculations to determine the mean absorbed doses to the embryo and fetus when the mother is exposed to neutron fields. A new set of mathematical models for the embryo and fetus has been developed at Health Canada and is used together with mathematical phantoms of a pregnant female developed at Oak Ridge National Laboratory. Monoenergetic neutrons from 1 eV to 10 MeV are considered in this study. The irradiation geometries include antero-posterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT) and isotropic (ISO) geometries. At each of these standard irradiation geometries, absorbed doses to the fetal brain and body are calculated; for the embryo at 8 weeks and the fetus at 3, 6 or 9 months. Neutron fluence-to-absorbed dose conversion coefficients are derived for the four age groups. Neutron fluence-to-equivalent dose conversion coefficients are given for the AP irradiations which yield the highest radiation dose to the fetal body in the neutron energy range considered here. The results indicate that for neutrons <10 MeV more protection should be given to pregnant women in the first trimester due to the higher absorbed dose per unit neutron fluence to the fetus.

  3. Calculation of conversion coefficients for radiological protection against external radiation exposures

    International Nuclear Information System (INIS)

    Zankl, M.

    2001-01-01

    Calculations are essential for radiation protection practice because organ doses and effective doses cannot be measured directly. Conversion coefficients describe the numerical relationships of protection quantities and operational quantities. The latter can be measured in practical situations using suitable dosimeters. The conversion coefficients are calculated using radiation transport codes - usually based on Monte Carlo methods - that simulate the interactions of radiation with matter in computational models of the human body. A new generation of human body models, the so-called voxel models, are constructed from image data of real persons using suitable image processing systems, consequently, they represent the human anatomy more realistically than the so-called mathematical models. The numerical effects of realistic body anatomy on the calculated conversion coefficients can amount to 70% and more for external exposures. (orig.) [de

  4. Systematic errors in the tables of theoretical total internal conversion coefficients

    International Nuclear Information System (INIS)

    Dragoun, O.; Rysavy, M.

    1992-01-01

    Some of the total internal conversion coefficients presented in widely used tables of Rosel et al (1978 Atom. Data Nucl. Data Tables 21, 291) were found to be erroneous. The errors appear for some low transition energies, all multipolarities, and probably for all elements. The origin of the errors is explained. The subshell conversion coefficients of Rosel et al, where available, agree with our calculations. to within a few percent. (author)

  5. Methods for calculating dose conversion coefficients for terrestrial and aquatic biota

    International Nuclear Information System (INIS)

    Ulanovsky, A.; Proehl, G.; Gomez-Ros, J.M.

    2008-01-01

    Plants and animals may be exposed to ionizing radiation from radionuclides in the environment. This paper describes the underlying data and assumptions to assess doses to biota due to internal and external exposure for a wide range of masses and shapes living in various habitats. A dosimetric module is implemented which is a user-friendly and flexible possibility to assess dose conversion coefficients for aquatic and terrestrial biota. The dose conversion coefficients have been derived for internal and various external exposure scenarios. The dosimetric model is linked to radionuclide decay and emission database, compatible with the ICRP Publication 38, thus providing a capability to compute dose conversion coefficients for any nuclide from the database and its daughter nuclides. The dosimetric module has been integrated into the ERICA Tool, but it can also be used as a stand-alone version

  6. Dose conversion coefficients for photon exposure of the human eye lens

    Science.gov (United States)

    Behrens, R.; Dietze, G.

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity Hp(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model—with the addition of the whole body—was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  7. Dose conversion coefficients for photon exposure of the human eye lens

    International Nuclear Information System (INIS)

    Behrens, R; Dietze, G

    2011-01-01

    In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity H p (3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model-with the addition of the whole body-was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.

  8. Total conversion coefficient of the 185 keV (10--7+) transition in sup(182m)Ta

    International Nuclear Information System (INIS)

    Suryanarayana, Ch.; Venkateswara Rao, N.; Raghavaiah, C.V.; Bhuloka Reddy, S.; Satyanarayana, G.; Sastry, D.L.

    1988-01-01

    The total conversion coefficient of the 185 keV (E3) isomeric transition in 182 Ta was measured for the first time using gamma intensity balance method. The experimental αsub(T) was obtained as 3.4 ± 0.2 consistent with the theoretical value (3.272) due to Rosel et al. The E3 transition probability was found to be hindered by a factor of 5.07x10 4 when compared to the single particle estimate. (author). 13 refs

  9. Total conversion coefficient of the 263 keV (21/sup 2//2->13/sup +//2) transition in sup(93m)Mo

    Energy Technology Data Exchange (ETDEWEB)

    Suryanaryana, C.; Venkateswara Rao, M.; Narayana, D.G.S.; Bhuloka Reddy, S.; Satyanarayana, G.; Sastry, D.L.; Chintalapudi, S.N.

    1985-01-01

    The total conversion coefficient of the 263 keV gamma transition in the decay scheme of sup(93m)Mo is measured by intensity balance method using a HP Ge spectrometer system. The experimental value of ..cap alpha..sub(T)(263 keV) is found to be 0.696 +- 0.05 which is in agreement with the theoretical values 0.72 and 0.7. The transition probability T(E4) is calculated using the present value of ..cap alpha..sub(T) and compared with the single-particle estimate. A good agreement is noted between the theory and the experiment for the value of T(E4).

  10. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    CERN Document Server

    Sakamoto, Y; Sato, O; Tanaka, S I; Tsuda, S; Yamaguchi, Y; Yoshizawa, N

    2003-01-01

    In the International Commission on Radiological Protection (ICRP) 1990 Recommendations, radiation weighting factors were introduced in the place of quality factors, the tissue weighting factors were revised, and effective doses and equivalent doses of each tissues and organs were defined as the protection quantities. Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of theses data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality fact...

  11. Determination of fluence-to-dose conversion coefficients by means of artificial neural networks

    International Nuclear Information System (INIS)

    Soto B, T. G.; Rivera P, E.; De Leon M, H. A.; Hernandez D, V. M.; Vega C, H. R.; Gallego, E.; Lorente, A.

    2012-10-01

    In this paper is presented an Artificial Neural Network (Ann) that has been designed, trained and validated to determinate the effective dose e, ambient dose equivalent h(10) and personal dose equivalent hp(10,θ) fluence-to-dose conversion coefficients at different positions, having as only input data 7 count rates obtained with a Bonner Sphere Spectrometer (Bss) system. A set of 211 neutron spectra and the fluence-to-dose conversion coefficients published by the International Atomic Energy Agency were used to train and validate the Ann. This set was divided into 2 subsets, one of 181 elements to train the Ann and the remaining 30 to validate it. The Ann was trained using Bss count rates as input data and the fluence-to-dose conversion coefficients as output data. The network was validated and tested with the set of 30 elements that were not used during the training process. Good results were obtained proving that Ann are a good choice for calculating the fluence-to-dose conversion coefficients having as only data the count rates obtained with a Bss. (Author)

  12. Determination of fluence-to-dose conversion coefficients by means of artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Soto B, T. G.; Rivera P, E.; De Leon M, H. A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Gallego, E.; Lorente, A., E-mail: tzinnia.soto@gmail.com [Universidad Politecnica de Madrid, Departamento de Ingenieria Nuclear, Jose Gutierrez Abascal No. 2, 28006 Madrid (Spain)

    2012-10-15

    In this paper is presented an Artificial Neural Network (Ann) that has been designed, trained and validated to determinate the effective dose e, ambient dose equivalent h(10) and personal dose equivalent hp(10,{theta}) fluence-to-dose conversion coefficients at different positions, having as only input data 7 count rates obtained with a Bonner Sphere Spectrometer (Bss) system. A set of 211 neutron spectra and the fluence-to-dose conversion coefficients published by the International Atomic Energy Agency were used to train and validate the Ann. This set was divided into 2 subsets, one of 181 elements to train the Ann and the remaining 30 to validate it. The Ann was trained using Bss count rates as input data and the fluence-to-dose conversion coefficients as output data. The network was validated and tested with the set of 30 elements that were not used during the training process. Good results were obtained proving that Ann are a good choice for calculating the fluence-to-dose conversion coefficients having as only data the count rates obtained with a Bss. (Author)

  13. Radon progeny dose conversion coefficients for Chinese males and females

    Energy Technology Data Exchange (ETDEWEB)

    Yu, K.N. E-mail: peter.yu@city.edu.hk; Cheung, T.T.K.; Haque, A.K.M.M.; Nikezic, D.; Lau, B.M.F.; Vucic, D

    2001-07-01

    The airway dimensions for Caucasian males have been scaled by multiplying by factors 0.95 and 0.88 to give those for Chinese males and females, respectively. Employing the most recent data on physical and biological parameters, the radiation doses to the basal and secretory cells due to {alpha} particles from {sup 218}Po and {sup 214}Po, homogeneously distributed in the mucous layer, have been calculated. The emission of {alpha} particles has been simulated by a Monte Carlo method. For both basal and secretory cells, the dose conversion coefficients (DCCs) for physical conditions of sleep, rest, light and heavy exercise, have been obtained for Chinese males and females for unattached progeny, and for attached progeny of diameters 0.02, 0.15, 0.25, 0.30 and 0.50 {mu}m. For basal cells, the coefficients lie in the range 0.69-6.82 mGy/(J s/m{sup 3}) or 8.7-86 mGy/WLM for unattached progeny and in the range 0.045-1.98 mGy/(J s/m{sup 3}) or 0.57-25 mGy/WLM for attached progeny. The corresponding ranges for Caucasian males are 1.27-8.81 mGy/(J s/m{sup 3}) or 16-111 mGy/WLM{sup -1} and 0.05-2.30 mGy/(J s/m{sup 3}) or 0.64-29 mGy/WLM. For secretory cells, the coefficients lie in the range 0.095-16.82 mGy/(J s/m{sup 3}) (1.2-212 mGy/WLM) for unattached progeny and in the range 0.095-6.67 mGy/(J s/m{sup 3}) (1.2-84 mGy/WLM) for attached progeny. The corresponding ranges for Caucasian males are 0.34-21.51 mGy/(J s/m{sup 3}) (4.3-271 mGy/WLM) and 0.1-7.78 mGy/(J s/m{sup 3}) (1.3-98 mGy/WLM). The overall DCCs calculated for a typical home environment are 0.59 and 0.52 mSv/(J s/m{sup 3}) (7.4 and 6.5 mSv/WLM) for Chinese males and females, respectively, which are 80 and 70% of the value, 0.73 mSv/(J s/m{sup 3}) (9.2 mSv/WLM), for Caucasian males.

  14. Study of the coefficients of internal conversion for transition energies approaching the threshold

    International Nuclear Information System (INIS)

    Farani Coursol, Nelcy.

    1979-01-01

    Internal conversion coefficients were determined experimentally with great accuracy for areas of transition energies, which constitute tests for the theories (energies at the most ten kEv above the threshold of K shell), then the results obtained were compared with the values calculated (or to be calculated) from theoretical models. Owing to the difficulties raised by the precise determination of the internal conversion coefficients (ICC), in the first stage we selected radionuclides with a relatively simple decay pattern, the transitions: 30 keV of sup(93m)Nb, 35 keV of sup(125m)Te, 14 keV of 57 Fe and 39 keV of sup(129m)Xe. It was observed that 'problems' exist with respect to the ICC's of the great multipolarity transitions, so the transitions of this kind were examined in a systematic manner. The possibility of penetration effects occurring for the transitions studied experimentally was examined. The considerations are presented which 'authorized' us to disregard the dynamic part of the ICC for the transitions approaching the threshold (L selection rules and life of nuclear levels in relation to Weisskopf-Moszkowski estimations). The Kurie straight line was determined experimentally for the β - transition and the Qsub(β) was evaluated with an important accuracy gain compared with the values available at present. Finally, a certain number of ICC's of transitions already determined with good precision were recalculated, in order to extend our analysis and detect any possible systematic errors [fr

  15. Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method

    International Nuclear Information System (INIS)

    Thomas, Karen E.; Wang, Bo

    2008-01-01

    There is a need for an easily accessible method for effective dose estimation in pediatric CT. To estimate effective doses for a variety of pediatric neurological and body CT examinations in five age groups using recently published age- and region-specific dose length product (DLP) to effective dose conversion coefficients. A retrospective review was performed of 1,431 consecutive CT scans over a 12-week period using age- and weight-adjusted CT protocols. Age- and region-specific DLP to effective dose conversion coefficients were applied to console-displayed DLP data. Effective dose estimates for single-phase head CT scans in neonatal, and 1-, 5-, 10- and 15-year-old age groups were 4.2, 3.6, 2.4, 2.0 and 1.4 mSv, respectively. For abdomen/pelvis CT scans the corresponding effective doses were 13.1, 11.1, 8.4, 8.9 and 5.9 mSv. The range of pediatric CT effective doses is wide, from ultralow dose protocols (<1 mSv) to extended-coverage body examinations (10-15 mSv). Age- and region-specific pediatric DLP to effective dose conversion coefficients provide an accessible and user-friendly method for estimating pediatric CT effective doses that is available to radiologists working without medical physics support. (orig.)

  16. CALCULATION OF FLUENCE-TO-EFFECTIVE DOSE CONVERSION COEFFICIENTS FOR THE OPERATIONAL QUANTITY PROPOSED BY ICRU RC26.

    Science.gov (United States)

    Endo, Akira

    2017-07-01

    Fluence-to-effective dose conversion coefficients have been calculated for photons, neutrons, electrons, positrons, protons, muons, pions and helium ions for various incident angles of radiations. The aim of this calculation is to provide a set of conversion coefficients to the Report Committee 26 (RC26) of the International Commission on Radiation Units and Measurements (ICRU) for use in defining personal dose equivalent for individual monitoring. The data sets comprise effective dose conversion coefficients for incident angles of radiations from 0° to ±90° in steps of 15° and at ±180°. Conversion coefficients for rotational, isotropic, superior hemisphere semi-isotropic and inferior hemisphere semi-isotropic irradiations are also included. Numerical data of the conversion coefficients are presented as supplementary data. The conversion coefficients are used to define the personal dose equivalent, which is being considered by the ICRU RC26, as the operational quantity for individual monitoring. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Photon dose conversion coefficients for the human teeth in standard irradiation geometries

    Energy Technology Data Exchange (ETDEWEB)

    Ulanovsky, A; Wieser, A; Zankl, M; Jacob, P

    2005-07-01

    Photon dose conversion coefficients for the human tooth materials are computed in energy range from 0.01 to 10 MeV by the Monte Carlo method. The voxel phantom Golem of the human body with newly defined tooth region and a modified version of the EGS4 code have been used to compute the coefficients for 30 tooth cells with different locations and materials. The dose responses are calculated for cells representing buccal and lingual enamel layers. The computed coefficients demonstrate a strong dependence on energy and geometry of the radiation source and a weaker dependence on location of the enamel voxels. For isotropic and rotational radiation fields the enamel dose does not show a significant dependence on tooth sample locations. The computed coefficients are used to convert from absorbed dose in teeth to organ dose or to integral air kerma. Examples of integral conversion factors from enamel dose to air kerma are given for several photon fluences specific for the Mayak reprocessing plant in Russia. The integral conversion factors are strongly affected by the energy and angular distributions of photon fluence, which are important characteristics of an exposure scenario for reconstruction of individual occupational doses. (orig.)

  18. Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures

    CERN Document Server

    Endo, A; Zankl, M; Bolch, W E; Eckerman, K F; Hertel, N E; Hunt, J G; Pelliccioni, M; Schlattl, H; Menzel, H-G

    2014-01-01

    This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors.

  19. Conversion coefficients for individual monitoring calculated with integrated tiger series, ITS3, Monte Carlo code

    International Nuclear Information System (INIS)

    Devine, R.T.; Hsu, Hsiao-Hua

    1994-01-01

    The current basis for conversion coefficients for calibrating individual photon dosimeters in terms of dose equivalents is found in the series of papers by Grosswent. In his calculation the collision kerma inside the phantom is determined by calculation of the energy fluence at the point of interest and the use of the mass energy absorption coefficient. This approximates the local absorbed dose. Other Monte Carlo methods can be sued to provide calculations of the conversion coefficients. Rogers has calculated fluence-to-dose equivalent conversion factors with the Electron-Gamma Shower Version 3, EGS3, Monte Carlo program and produced results similar to Grosswent's calculations. This paper will report on calculations using the Integrated TIGER Series Version 3, ITS3, code to calculate the conversion coefficients in ICRU Tissue and in PMMA. A complete description of the input parameters to the program is given and comparison to previous results is included

  20. Simulation codes to evcaluate dose conversion coefficients for hadrons over 10 GeV

    International Nuclear Information System (INIS)

    Sato, T.; Tsuda, S.; Sakamoto, Y.; Yamaguchi, Y.; Niita, K.

    2002-01-01

    The conversion coefficients from fluence to effective dose for high energy hadrons are indispensable for various purposes such as accelerator shielding design and dose evaluation in space mission. Monte Carlo calculation code HETC-3STEP was used to evaluate dose conversion coefficients for neutrons and protons up to 10 GeV with an anthropomorphic model. The scaling model was incorporated in the code for simulation of high energy nuclear reactions. However, the secondary particle energy spectra predicted by the model were not smooth for nuclear reactions over several GeV. We attempted, therefore, to simulate transportation of such high energy particles by two newly developed Monte Carlo simulation codes: one is HETC-3STEP including the model used in EVENTQ instead of the scaling model, and the other is NMTC/JAM. By comparing calculated cross sections by these codes with experimental data for high energy nuclear reactions, it was found that NMTC/JAM had a better agreement with the data. We decided, therefore, to adopt NMTC/JAM for evaluation of dose conversion coefficients for hadrons with energies over 10 GeV. The effective dose conversion coefficients for high energy neutrons and protons evaluated by NMTC/JAM were found to be close to those by the FLUKA code

  1. Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures

    International Nuclear Information System (INIS)

    Endo, Akira; Petoussi-Henss, Nina; Zankl, Maria; Schlattl, Helmut; Bolch, Wesley E.; Eckerman, Keith F.; Hertel, Nolan E.; Hunt, John G.; Pelliccioni, Maurizio; Menzel, Hans-Georg

    2014-01-01

    This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors. This paper briefly reviews the reference computational phantoms and dose conversion coefficients for external exposures that were published jointly by ICRP and ICRU. Both these publications appeared as a consequence of the ICRP 2007 Recommendations; to implement these recommendations, the ICRP has developed reference computational phantoms representing the adult male and female. These phantoms are used to calculate reference dose conversion coefficients for external and internal sources. Using the reference phantoms and methodology consistent with the 2007 Recommendations, dose conversion coefficients for both effective doses and organ-absorbed doses for various types of idealised external exposures have been calculated. These data sets supersede the existing ICRP/ICRU data sets and expand the particle types and energy ranges. For neutrons, the new effective dose conversion coefficients become smaller compared with those in ICRP74, for energies below hundreds of keV. This is mainly

  2. Fluence to Dose Equivalent Conversion Coefficients for Evaluation of Accelerator Radiation Environments

    International Nuclear Information System (INIS)

    Thomas, Ralph H.; Zeman, Gary H.

    2001-01-01

    The derivation of a set of conversion functions for the expression of neutron fluence measurements in terms of Effective Dose, E, is described. Four functions in analytical form are presented, covering the neutron energy range from 2.5 10-8 to 10+4 MeV, for the interpretation of fluence measurements in the typical irradiation conditions experienced around high-energy proton accelerators such as the Bevatron. For neutron energies below 200 MeV the analytical functions were modeled after the ISO and ROT conversion coefficients in ICRU 57. For neutron energies above 200 MeV, the analytical function was derived from an analysis of recent published data. Sample calculations using either the analytical expressions or the tabulated conversion coefficients from which the analytical expressions are derived show agreement to better than plus/minus 5%

  3. Calculation of age-dependent dose conversion coefficients for radionuclides uniformly distributed in air

    International Nuclear Information System (INIS)

    Hung, Tran Van; Satoh, Daiki; Takahashi, Fumiaki; Tsuda, Shuichi; Endo, Akira; Saito, Kimiaki; Yamaguchi, Yasuhiro

    2005-02-01

    Age-dependent dose conversion coefficients for external exposure to photons emitted by radionuclides uniformly distributed in air were calculated. The size of the source region in the calculation was assumed to be effectively semi-infinite in extent. Firstly, organ doses were calculated with a series of age-specific MIRD-5 type phantoms using MCNP code, a Monte Carlo transport code. The calculations were performed for mono-energetic photon sources of twelve energies from 10 keV to 5 MeV and for phantoms of newborn, 1, 5, 10 and 15 years, and adult. Then, the effective doses to the different age-phantoms from the mono-energetic photon sources were estimated based on the obtained organ doses. The calculated effective doses were used to interpolate the conversion coefficients of the effective doses for 160 radionuclides, which are important for dose assessment of nuclear facilities. In the calculation, energies and intensities of emitted photons from radionuclides were taken from DECDC, a recent compilation of decay data for radiation dosimetry developed at JAERI. The results are tabulated in the form of effective dose per unit concentration and time (Sv per Bq s m -3 ). (author)

  4. Comparing Hp(3) evaluated from the conversion coefficients from air kerma to personal dose equivalent for eye lens dosimetry calibrated on a new cylindrical PMMA phantom

    Science.gov (United States)

    Esor, J.; Sudchai, W.; Monthonwattana, S.; Pungkun, V.; Intang, A.

    2017-06-01

    Based on a new occupational dose limit recommended by ICRP (2011), the annual dose limit for the lens of the eye for workers should be reduced from 150 mSv/y to 20 mSv/y averaged over 5 consecutive years in which no single year exceeding 50 mSv. This new dose limit directly affects radiologists and cardiologists whose work involves high radiation exposure over 20 mSv/y. Eye lens dosimetry (Hp(3)) has become increasingly important and should be evaluated directly based on dosimeters that are worn closely to the eye. Normally, Hp(3) dose algorithm was carried out by the combination of Hp(0.07) and Hp(10) values while dosimeters were calibrated on slab PMMA phantom. Recently, there were three reports from European Union that have shown the conversion coefficients from air kerma to Hp(3). These conversion coefficients carried out by ORAMED, PTB and CEA Saclay projects were performed by using a new cylindrical head phantom. In this study, various delivered doses were calculated using those three conversion coefficients while nanoDot, small OSL dosimeters, were used for Hp(3) measurement. These calibrations were performed with a standard X-ray generator at Secondary Standard Dosimetry Laboratory (SSDL). Delivered doses (Hp(3)) using those three conversion coefficients were compared with Hp(3) from nanoDot measurements. The results showed that percentage differences between delivered doses evaluated from the conversion coefficient of each project and Hp(3) doses evaluated from the nanoDots were found to be not exceeding -11.48 %, -8.85 % and -8.85 % for ORAMED, PTB and CEA Saclay project, respectively.

  5. Conversion coefficients for determining organ doses in paediatric pelvis and hip joint radiography

    International Nuclear Information System (INIS)

    Seidenbusch, Michael C.; Schneider, Karl

    2014-01-01

    Knowledge of organ and effective doses achieved during paediatric X-ray examinations is an important prerequisite for assessment of radiation burden to the patient. Conversion coefficients for reconstruction of organ and effective doses from entrance doses for pelvis and hip joint radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients are provided regarding the Guidelines of Good Radiographic Technique of the European Commission. Using the personal computer program PCXMC developed by the Finnish Centre for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional pelvis and hip joint radiographs were calculated by performing Monte Carlo simulations in mathematical hermaphrodite phantom models representing patients of different ages. The clinical variation of radiation field settings was taken into consideration by defining optimal and suboptimal standard field settings. Conversion coefficients for the reconstruction of organ doses in about 40 organs and tissues from measured entrance doses during pelvis and hip joint radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients were calculated for the standard sagittal beam projection and the standard focus detector distance of 115 cm. The conversion coefficients presented can be used for organ dose assessments from entrance doses measured during pelvis and hip joint radiographs of children and young adults with all field settings within the optimal and suboptimal standard field settings. (orig.)

  6. Internal conversion coefficients of high multipole transitions: Experiment and theories

    International Nuclear Information System (INIS)

    Gerl, J.; Vijay Sai, K.; Sainath, M.; Gowrishankar, R.; Venkataramaniah, K.

    2008-01-01

    A compilation of the available experimental internal conversion coefficients (ICCs), α T , α K , α L , and ratios K/L and K/LM of high multipole (L > 2) transitions for a number of elements in the range 21 ≤ Z ≤ 94 is presented. Our listing of experimental data includes 194 data sets on 110 E3 transitions, 10 data sets on 6 E4 transitions, 11 data sets on 7 E5 transitions, 38 data sets on 21 M3 transitions, and 132 data sets on 68 M4 transitions. Data with less than 10% experimental uncertainty have been selected for comparison with the theoretical values of Hager and Seltzer [R.S. Hager, E.C. Seltzer, Nucl. Data Tables A 4 (1968) 1], Rosel et al. [F. Roesel, H.M. Fries, K. Alder, H.C. Pauli, At. Data Nucl. Data Tables 21 (1978) 91], and BRICC. The relative percentage deviations (%Δ) have been calculated for each of the above theories and the averages (%Δ-bar) are estimated. The Band et al. [I.M. Band, M.B. Trzhaskovskaya, C.W. Nestor Jr., P.O. Tikkanen, S. Raman, At. Data Nucl. Data Tables 81 (2002) 1] tables, using the BRICC interpolation code, are seen to give theoretical ICCs closest to experimental values

  7. Internal Dose Conversion Coefficients of Domestic Reference Animal and Plants for Dose Assessment of Non-human Species

    International Nuclear Information System (INIS)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Choi, Yong Ho

    2009-01-01

    Traditionally, radiation protection has been focused on a radiation exposure of human beings. In the international radiation protection community, one of the recent key issues is to establish the methodology for assessing the radiological impact of an ionizing radiation on non-human species for an environmental protection. To assess the radiological impact to non-human species dose conversion coefficients are essential. This paper describes the methodology to calculate the internal dose conversion coefficient for non-human species and presents calculated internal dose conversion coefficients of 25 radionuclides for 8 domestic reference animal and plants

  8. Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures

    Science.gov (United States)

    Schlattl, H.; Zankl, M.; Petoussi-Henss, N.

    2007-04-01

    A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360° rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%.

  9. Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposures

    International Nuclear Information System (INIS)

    Schlattl, H; Zankl, M; Petoussi-Henss, N

    2007-01-01

    A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360 deg. rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%

  10. New quantities in radiation protection and conversion coefficients

    International Nuclear Information System (INIS)

    1986-01-01

    Four new quantities have been proposed by the ICRP for use in radiation protection from external sources, i.e. the ambient dose equivalent, the directional dose equivalent, the individual dose equivalent (penetrating), and the individual dose equivalent (superficial). These quantities are briefly described together with two new concepts of expanded and aligned fields. The BCRU recommends that these quantities should be adopted for use in the UK together with conversion coefficients when re-calibrating existing instruments, reporting the results of measurements and designing instruments. (UK)

  11. Determination of the Rate Coefficients of the SO2 plus O plus M yields SO3 plus M Reaction

    Science.gov (United States)

    Hwang, S. M.; Cooke, J. A.; De Witt, K. J.; Rabinowitz, M. J.

    2010-01-01

    Rate coefficients of the title reaction R(sub 31) (SO2 +O+M yields SO3 +M) and R(sub 56) (SO2 + HO2 yields SO3 +OH), important in the conversion of S(IV) to S(VI),were obtained at T =970-1150 K and rho (sub ave) = 16.2 micro mol/cubic cm behind reflected shock waves by a perturbation method. Shock-heated H2/ O2/Ar mixtures were perturbed by adding small amounts of SO2 (1%, 2%, and 3%) and the OH temporal profiles were then measured using laser absorption spectroscopy. Reaction rate coefficients were elucidated by matching the characteristic reaction times acquired from the individual experimental absorption profiles via simultaneous optimization of k(sub 31) and k(sub 56) values in the reaction modeling (for satisfactory matches to the observed characteristic times, it was necessary to take into account R(sub 56)). In the experimental conditions of this study, R(sub 31) is in the low-pressure limit. The rate coefficient expressions fitted using the combined data of this study and the previous experimental results are k(sub 31,0)/[Ar] = 2.9 10(exp 35) T(exp ?6.0) exp(?4780 K/T ) + 6.1 10(exp 24) T(exp ?3.0) exp(?1980 K/T ) cm(sup 6) mol(exp ?2)/ s at T = 300-2500 K; k(sub 56) = 1.36 10(exp 11) exp(?3420 K/T ) cm(exp 3)/mol/s at T = 970-1150 K. Computer simulations of typical aircraft engine environments, using the reaction mechanism with the above k(sub 31,0) and k(sub 56) expressions, gave the maximum S(IV) to S(VI) conversion yield of ca. 3.5% and 2.5% for the constant density and constant pressure flow condition, respectively. Moreover, maximum conversions occur at rather higher temperatures (?1200 K) than that where the maximum k(sub 31,0) value is located (approximately 800 K). This is because the conversion yield is dependent upon not only the k(sup 31,0) and k(sup 56) values (production flux) but also the availability of H, O, and HO2 in the system (consumption flux).

  12. Dose conversion coefficients for electron exposure of the human eye lens

    International Nuclear Information System (INIS)

    Behrens, R; Dietze, G; Zankl, M

    2009-01-01

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity H p (0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity H p (3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0 deg. and 45 deg. are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.

  13. Dose conversion coefficients based on the Chinese mathematical phantom and MCNP code for external photon irradiation

    International Nuclear Information System (INIS)

    Qiu, R.; Li, J.; Zhang, Z.; Liu, L.; Bi, L.; Ren, L.

    2009-01-01

    A set of conversion coefficients from kerma free-in-air to the organ-absorbed dose are presented for external monoenergetic photon beams from 10 keV to 10 MeV based on the Chinese mathematical phantom, a whole-body mathematical phantom model. The model was developed based on the methods of the Oak Ridge National Laboratory mathematical phantom series and data from the Chinese Reference Man and the Reference Asian Man. This work is carried out to obtain the conversion coefficients based on this model, which represents the characteristics of the Chinese population, as the anatomical parameters of the Chinese are different from those of Caucasians. Monte Carlo simulation with MCNP code is carried out to calculate the organ dose conversion coefficients. Before the calculation, the effects from the physics model and tally type are investigated, considering both the calculation efficiency and precision. In the calculation irradiation conditions include anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic geometries. Conversion coefficients from this study are compared with those recommended in the Publication 74 of International Commission on Radiological Protection (ICRP74) since both the sets of data are calculated with mathematical phantoms. Overall, consistency between the two sets of data is observed and the difference for more than 60% of the data is below 10%. However, significant deviations are also found, mainly for the superficial organs (up to 65.9%) and bone surface (up to 66%). The big difference of the dose conversion coefficients for the superficial organs at high photon energy could be ascribed to kerma approximation for the data in ICRP74. Both anatomical variations between races and the calculation method contribute to the difference of the data for bone surface. (authors)

  14. Dose conversion coefficients based on the Chinese mathematical phantom and MCNP code for external photon irradiation.

    Science.gov (United States)

    Qiu, Rui; Li, Junli; Zhang, Zhan; Liu, Liye; Bi, Lei; Ren, Li

    2009-02-01

    A set of conversion coefficients from kerma free-in-air to the organ-absorbed dose are presented for external monoenergetic photon beams from 10 keV to 10 MeV based on the Chinese mathematical phantom, a whole-body mathematical phantom model. The model was developed based on the methods of the Oak Ridge National Laboratory mathematical phantom series and data from the Chinese Reference Man and the Reference Asian Man. This work is carried out to obtain the conversion coefficients based on this model, which represents the characteristics of the Chinese population, as the anatomical parameters of the Chinese are different from those of Caucasians. Monte Carlo simulation with MCNP code is carried out to calculate the organ dose conversion coefficients. Before the calculation, the effects from the physics model and tally type are investigated, considering both the calculation efficiency and precision. In the calculation irradiation conditions include anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic geometries. Conversion coefficients from this study are compared with those recommended in the Publication 74 of International Commission on Radiological Protection (ICRP74) since both the sets of data are calculated with mathematical phantoms. Overall, consistency between the two sets of data is observed and the difference for more than 60% of the data is below 10%. However, significant deviations are also found, mainly for the superficial organs (up to 65.9%) and bone surface (up to 66%). The big difference of the dose conversion coefficients for the superficial organs at high photon energy could be ascribed to kerma approximation for the data in ICRP74. Both anatomical variations between races and the calculation method contribute to the difference of the data for bone surface.

  15. Internal and external dose conversion coefficient for domestic reference animals and plant

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong Kwon; Jun, In; Lim, Kwang Muk; Park, Du Won; Choi, Young Ho

    2009-07-15

    This report presents the internal and external dose conversion coefficients for domestic reference animals and plant, which are essential to assess the radiological impact of an environmental radiation on non-human species. To calculate the dose conversion coefficients, a uniform isotropic model and a Monte Carlo method for a photon transport simulation in environmental media with different densities have been applied for aquatic and terrestrial animals, respectively. In the modeling all the target animals are defined as a simple 3D elliptical shape. To specify the external radiation source it is assumed that aquatic animals are fully immersed in infinite and uniformly contaminated water, and the on-soil animals are living on the surface of a horizontally infinite soil source, and the in-soil organisms are living at the center of a horizontally infinite and uniformly contaminated soil to a depth of 50cm. A set of internal and external dose conversion coefficients for 8 Korean reference animals and plant (rat, roe-deer, frog, snake, Chinese minnow, bee, earthworm, and pine tree) are presented for 25 radionuclides ({sup 3}H, {sup 7}Be, {sup 14}C, {sup 40}K, {sup 51}Cr, {sup 54}Mn, {sup 59}Fe, {sup 58}Co, {sup 60}Co, {sup 65}Zn, {sup 90}Sr, {sup 95}Zr, {sup 95}Nb, {sup 99}Tc, {sup 106}Ru, {sup 129}I, {sup 131}I, {sup 136}Cs, {sup 137}Cs, {sup 140}Ba, {sup 140}La, {sup 144}Ce, {sup 238}U, {sup 239}Pu, and {sup 240}Pu)

  16. Outlines of ICRP publication 74 and new dose conversion coefficients for external radiation

    International Nuclear Information System (INIS)

    Yamaguchi, Yasuhiro

    1998-01-01

    Combined task group of ICRP and ICRU reported the ICRP Publication 74 (1996) which is a summary report of their collection, analysis and evaluation of many data and dose conversion coefficients. Concerning the new coefficients, the author described this review as follows: History until Publication 74. Doses recommended at present: for protection quantity, the mean absorption dose of organ and tissue, equivalent dose and effective dose and for operational quantity, the ambient dose equivalent, directional dose equivalent and individual dose equivalent. Changes which can have an influence on the dose evaluation; introduction of radiation weighting factor (WR), changing of tissue weighting factor (WR), changing of the equation for Q-L relation and updating of physical data. New dose conversion coefficients; for photon, neutron and electron. Comparison of new and present coefficients; concerning the quality factor Q, particularly for neutron Q. New relations of protection and operational quantities; for field and individual monitoring. General conclusion of Publication 74. The Publication gives a certain direction for problems in evaluation of external exposure dose which have been discussed since the ICRP Fundamental Recommendation 1990 was issued. However, there still remain many problems especially in validity of the WR and of equation for Q-L relation. (K.H.)

  17. Dose conversion coefficients calculated using a series of adult Japanese voxel phantoms against external photon exposure

    International Nuclear Information System (INIS)

    Sato, Kaoru; Endo, Akira; Saito, Kimiaki

    2008-10-01

    This report presents a complete set of conversion coefficients of organ doses and effective doses calculated for external photon exposure using five Japanese adult voxel phantoms developed at the Japan Atomic Energy Agency (JAEA). At the JAEA, high-resolution Japanese voxel phantoms have been developed to clarify the variation of organ doses due to the anatomical characteristics of Japanese, and three male phantoms (JM, JM2 and Otoko) and two female phantoms (JF and Onago) have been constructed up to now. The conversion coefficients of organ doses and effective doses for the five voxel phantoms have been calculated for six kinds of idealized irradiation geometries from monoenergetic photons ranging from 0.01 to 10 MeV using EGS4, a Monte Carlo code for the simulation of coupled electron-photon transport. The dose conversion coefficients are given as absorbed dose and effective dose per unit air-kerma free-in-air, and are presented in tables and figures. The calculated dose conversion coefficients are compared with those of voxel phantoms based on the Caucasian and the recommended values in ICRP74 in order to discuss (1) variation of organ dose due to the body size and individual anatomy, such as position and shape of organs, and (2) effect of posture on organ doses. The present report provides valuable data to study the influence of the body characteristics of Japanese upon the organ doses and to discuss developing reference Japanese and Asian phantoms. (author)

  18. Organ dose conversion coefficients based on a voxel mouse model and MCNP code for external photon irradiation.

    Science.gov (United States)

    Zhang, Xiaomin; Xie, Xiangdong; Cheng, Jie; Ning, Jing; Yuan, Yong; Pan, Jie; Yang, Guoshan

    2012-01-01

    A set of conversion coefficients from kerma free-in-air to the organ absorbed dose for external photon beams from 10 keV to 10 MeV are presented based on a newly developed voxel mouse model, for the purpose of radiation effect evaluation. The voxel mouse model was developed from colour images of successive cryosections of a normal nude male mouse, in which 14 organs or tissues were segmented manually and filled with different colours, while each colour was tagged by a specific ID number for implementation of mouse model in Monte Carlo N-particle code (MCNP). Monte Carlo simulation with MCNP was carried out to obtain organ dose conversion coefficients for 22 external monoenergetic photon beams between 10 keV and 10 MeV under five different irradiation geometries conditions (left lateral, right lateral, dorsal-ventral, ventral-dorsal, and isotropic). Organ dose conversion coefficients were presented in tables and compared with the published data based on a rat model to investigate the effect of body size and weight on the organ dose. The calculated and comparison results show that the organ dose conversion coefficients varying the photon energy exhibits similar trend for most organs except for the bone and skin, and the organ dose is sensitive to body size and weight at a photon energy approximately <0.1 MeV.

  19. SU-D-209-06: Study On the Dose Conversion Coefficients in Pediatric Radiography with the Development of Children Voxel Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Q [Institute of Radiation Medicine Fudan University, Shanghai (China); Shanghai General Hospital, Shanghai, Shanghai (China); Zhuo, W; Liu, H [Institute of Radiation Medicine Fudan University, Shanghai (China); Liu, Y; Chen, T [Shanghai General Hospital, Shanghai, Shanghai (China)

    2016-06-15

    Purpose: Conversion coefficients of organ dose normalized to entrance skin dose (ESD) are widely used to evaluate the organ doses directly using ESD without time-consuming dose measurement, this work aims to investigate the dose conversion coefficients in pediatric chest and abdomen radiography with the development of 5 years and 10 years old children voxel phantoms. Methods: After segmentation of organs and tissues from CT slice images of ATOM tissue-equivalent phantoms, a 5-year-old and a 10-year-old children computational voxel phantoms were developed for Monte Carlo simulation. The organ doses and the entrance skin dose for pediatric chest postero-anterior projection and abdominal antero-posterior projection were simulated at the same time, and then the organ dose conversion coefficients were calculated.To verify the simulated results, dose measurement was carried out with ATOM tissue-equivalent phantoms for 5 year chest radiography. Results: Simulated results and experimental results matched very well with each other, the result differences of all the organs covered in radiation field were below 16% for 5-year-old child in chest projection. I showed that the conversion coefficients of organs covered in the radiation field were much larger than organs out of the field for all the study cases, for example, the conversion coefficients of stomach, liver intestines, and pancreas are larger for abdomen radiography while conversion coefficients of lungs are larger for chest radiography. Conclusion: The voxel children phantoms were helpful to evaluate the radiation doses more accurately and efficiently. Radiation field was the essential factor that affects the organ dose, use reasonably small field should be encouraged for radiation protection. This work was supported by the National Natural Science Foundation of China(11475047)

  20. SU-D-209-06: Study On the Dose Conversion Coefficients in Pediatric Radiography with the Development of Children Voxel Phantoms

    International Nuclear Information System (INIS)

    Liu, Q; Zhuo, W; Liu, H; Liu, Y; Chen, T

    2016-01-01

    Purpose: Conversion coefficients of organ dose normalized to entrance skin dose (ESD) are widely used to evaluate the organ doses directly using ESD without time-consuming dose measurement, this work aims to investigate the dose conversion coefficients in pediatric chest and abdomen radiography with the development of 5 years and 10 years old children voxel phantoms. Methods: After segmentation of organs and tissues from CT slice images of ATOM tissue-equivalent phantoms, a 5-year-old and a 10-year-old children computational voxel phantoms were developed for Monte Carlo simulation. The organ doses and the entrance skin dose for pediatric chest postero-anterior projection and abdominal antero-posterior projection were simulated at the same time, and then the organ dose conversion coefficients were calculated.To verify the simulated results, dose measurement was carried out with ATOM tissue-equivalent phantoms for 5 year chest radiography. Results: Simulated results and experimental results matched very well with each other, the result differences of all the organs covered in radiation field were below 16% for 5-year-old child in chest projection. I showed that the conversion coefficients of organs covered in the radiation field were much larger than organs out of the field for all the study cases, for example, the conversion coefficients of stomach, liver intestines, and pancreas are larger for abdomen radiography while conversion coefficients of lungs are larger for chest radiography. Conclusion: The voxel children phantoms were helpful to evaluate the radiation doses more accurately and efficiently. Radiation field was the essential factor that affects the organ dose, use reasonably small field should be encouraged for radiation protection. This work was supported by the National Natural Science Foundation of China(11475047)

  1. Age-dependent conversion coefficients for organ doses and effective doses for external neutron irradiation

    International Nuclear Information System (INIS)

    Nishizaki, Chihiro; Endo, Akira; Takahashi, Fumiaki

    2006-06-01

    To utilize dose assessment of the public for external neutron irradiation, conversion coefficients of absorbed doses of organs and effective doses were calculated using the numerical simulation technique for six different ages (adult, 15, 10, 5 and 1 years and newborn), which represent the member of the public. Calculations were performed using six age-specific anthropomorphic phantoms and a Monte Carlo radiation transport code for two irradiation geometries, anterior-posterior and rotational geometries, for 20 incident energies from thermal to 20 MeV. Effective doses defined by the 1990 Recommendation of ICRP were calculated from the absorbed doses in 21 organs. The calculated results were tabulated in the form of absorbed doses and effective doses per unit neutron fluence. The calculated conversion coefficients are used for dose assessment of the public around nuclear facilities and accelerator facilities. (author)

  2. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Ra; Min, Byung Il; Park, Kihyun; Yang, Byung Mo; Suh, Kyung Suk [Nuclear Environmental Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment.

  3. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR

    International Nuclear Information System (INIS)

    Kim, So Ra; Min, Byung Il; Park, Kihyun; Yang, Byung Mo; Suh, Kyung Suk

    2016-01-01

    The International Commission on Radiological Protection (ICRP) recommendations and the Federal Guidance Report (FGR) published by the U.S. Environmental Protection Agency (EPA) have been widely applied worldwide in the fields of radiation protection and dose assessment. The dose conversion coefficients of the ICRP and FGR are widely used for assessing exposure doses. However, before the coefficients are used, the user must thoroughly understand the derivation process of the coefficients to ensure that they are used appropriately in the evaluation. The ICRP provides recommendations to regulatory and advisory agencies, mainly in the form of guidance on the fundamental principles on which appropriate radiological protection can be based. The FGR provides federal and state agencies with technical information to assist their implementation of radiation protection programs for the U.S. population. The system of radiation dose assessment and dose conversion coefficients in the ICRP and FGR is reviewed in this study. A thorough understanding of their background is essential for the proper use of dose conversion coefficients. The FGR dose assessment system was strongly influenced by the ICRP and the U.S. National Council on Radiation Protection and Measurements (NCRP), and is hence consistent with those recommendations. Moreover, the ICRP and FGR both used the scientific data reported by Biological Effects of Ionizing Radiation (BEIR) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) as their primary source of information. The difference between the ICRP and FGR lies in the fact that the ICRP utilized information regarding a population of diverse races, whereas the FGR utilized data on the American population, as its goal was to provide guidelines for radiological protection in the US. The contents of this study are expected to be utilized as basic research material in the areas of radiation protection and dose assessment

  4. Calculation of neutron fluence to dose equivalent conversion coefficients using GEANT4

    International Nuclear Information System (INIS)

    Ribeiro, Rosane M.; Santos, Denison de S.; Queiroz Filho, Pedro P. de; Mauricio, CLaudia L.P.; Silva, Livia K. da; Pessanha, Paula R.

    2014-01-01

    Fluence to dose equivalent conversion coefficients provide the basis for the calculation of area and personal monitors. Recently, the ICRP has started a revision of these coefficients, including new Monte Carlo codes for benchmarking. So far, little information is available about neutron transport below 10 MeV in tissue-equivalent (TE) material performed with Monte Carlo GEANT4 code. The objective of this work is to calculate neutron fluence to personal dose equivalent conversion coefficients, H p (10)/Φ, with GEANT4 code. The incidence of monoenergetic neutrons was simulated as an expanded and aligned field, with energies ranging between thermal neutrons to 10 MeV on the ICRU slab of dimension 30 x 30 x 15 cm 3 , composed of 76.2% of oxygen, 10.1% of hydrogen, 11.1% of carbon and 2.6% of nitrogen. For all incident energy, a cylindrical sensitive volume is placed at a depth of 10 mm, in the largest surface of the slab (30 x 30 cm 2 ). Physic process are included for neutrons, photons and charged particles, and calculations are made for neutrons and secondary particles which reach the sensitive volume. Results obtained are thus compared with values published in ICRP 74. Neutron fluence in the sensitive volume was calculated for benchmarking. The Monte Carlo GEANT4 code was found to be appropriate to calculate neutron doses at energies below 10 MeV correctly. (author)

  5. ESTIMATION OF THE CONVERSION COEFFICIENTS FROM DOSE-AREA PRODUCT TO EFFECTIVE DOSE FOR BARIUM MEAL EXAMINATIONS FOR ADULT PATIENTS

    Directory of Open Access Journals (Sweden)

    A. V. Vodovatov

    2018-01-01

    Full Text Available Fluoroscopic examinations of the upper gastro-intestinal tract and, especially, barium meal examinations, are commonly performed in a majority of hospitals. These examinations are associated both with substantial individual patient doses and contribution to the collective dose from medical exposure. Effective dose estimation for this type of examinations is complicated due to: 1 the necessity to simulate the moving X-ray irradiation field; 2 differences in study structure for the individual patients; 3 subjectivity of the operators; and 4 differences in the X-ray equipment. The aim of the current study was to estimate conversion coefficients from dose-area product to effective dose for barium meal examinations for the over couch and under couch exposure conditions. The study was based on data collected in the X-ray unit of the surgical department of the St-Petersburg Mariinsky hospital. A model of patient exposure during barium meal examination was developed based on the collected data on fluoroscopy protocols and adult patient irradiation geometry. Conversion coefficients were calculated using PCXMC 2.0 software. Complete examinations were converted into a set of typical fluoroscopy phases and X-ray images, specified by the examined anatomical region and the projection of patient exposure. Conversion coefficients from dose-area product to effective dose were calculated for each phase of the examination and for the complete examination. The resulting values of the conversion coefficients are comparable with published data. Variations in the absolute values of the conversion coefficients can be explained by differences in clinical protocols, models for the estimation of the effective dose and parameters of barium meal examinations. The proposed approach for estimation of effective dose considers such important features of fluoroscopic examinations as: 1 non-uniform structure of examination, 2 significant movement of the X-ray tube within a single

  6. Determination of average conversion coefficients between kerma in air and H⁎(10) using primary and secondary X-ray beams and transmitted in the diagnostic radiology energy range

    International Nuclear Information System (INIS)

    Santos, Josilene C.; Gonzalez, Alejandro H.L.; Costa, Paulo R.

    2016-01-01

    Brazilian regulation establishes 1.14 Sv/Gy as unique conversion coefficient to convert air-kerma into the operational quantity ambient dose equivalent H⁎(10) disregarding its beam quality dependence. The present study computed mean conversion coefficients from primary, secondary and transmitted X-ray beams through barite mortar plates used in shielding of dedicated chest radiographic facilities in order to improve the current assessment of H⁎(10). To compute the mean conversion coefficients, the weighting of conversion coefficients corresponding to monoenergetic beams with the spectrum energy distribution in terms of air-kerma was considered. The maximum difference between the obtained conversion coefficients and the constant value recommended in national regulation is 53.4%. The conclusion based on these results is that a constant coefficient is not adequate for deriving the H⁎(10) from air-kerma measurements. (author)

  7. Applicability of dose conversion coefficients of ICRP 74 to Asian adult males: Monte Carlo simulation study

    International Nuclear Information System (INIS)

    Lee, Choonsik; Lee, Choonik; Lee, Jai-Ki

    2007-01-01

    International Commission on Radiological Protection (ICRP) reported comprehensive dose conversion coefficients for adult population, which is exposed to external photon sources in the Publication 74. However, those quantities were calculated from so-called stylized (or mathematical) phantoms composed of simplified mathematical surface equations so that the discrepancy between the phantoms and real human anatomy has been investigated by several authors using Caucasian-based voxel phantoms. To address anatomical and racial limitations of the stylized phantoms, several Asian-based voxel phantoms have been developed by Korean and Japanese investigators, independently. In the current study, photon dose conversion coefficients of ICRP 74 were compared with those from a total of five Asian-based male voxel phantoms, whose body dimensions were almost identical. Those of representative radio-sensitive organs (testes, red bone marrow, colon, lungs, and stomach), and effective dose conversion coefficients were obtained for comparison. Even though organ doses for testes, colon and lungs, and effective doses from ICRP 74 agreed well with those from Asian voxel phantoms within 10%, absorbed doses for red bone marrow and stomach showed significant discrepancies up to 30% which was mainly attributed to difference of phantom description between stylized and voxel phantoms. This study showed that the ICRP 74 dosimetry data, which have been reported to be unrealistic compared to those from Caucasian-based voxel phantoms, are also not appropriate for Asian population

  8. Internal conversion coefficients for atomic numbers Z less than or equal to 30

    International Nuclear Information System (INIS)

    Band, I.M.; Trzhaskovskaya, M.B.; Listengarten, M.A.

    1976-01-01

    Presented here are internal conversion coefficients (ICC) of gamma rays for 20 values of atomic number, Z, in the range 3 less than or equal to Z less than or equal to 30, including all Z greater than or equal to 14. The tables provide the previously missing data for light elements. Coefficients are given for 19 values of gamma-ray transition energies up to 6 MeV for the K-electron shell and 18 values up to 2 MeV for three L-subshells. The minimum enegy is 15 keV. The first five electric and magnetic nuclear transition multipolarities are covered. The calculations are relativistic, with screening and finite nuclear size effect taken into account

  9. Measurement of conversion coefficients between air Kerma and personal dose equivalent and backscatter factors for diagnostic X-ray beams

    International Nuclear Information System (INIS)

    Rosado, Paulo Henrique Goncalves

    2008-01-01

    Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm 3 Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm x 300 mm x 150 mm polymethylmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with 133 Ba, 241 Am and 57 Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of conversion coefficients and

  10. The Disintegration of {sup 103}Rh{sup m}

    Energy Technology Data Exchange (ETDEWEB)

    Czock, K. H.; Haselberger, N.; Reichel, F. [International Atomic Energy Agency, Vienna (Austria)

    1974-09-15

    A technique for determination of the disintegration rate of {sup 103}Rh{sup m} in thick foils is described. In addition values for the following parameters were determined: - total internal conversion coefficient {alpha} = 1531 {+-} 30; - K shell internal conversion coefficient {alpha}{sub K} = 127 {+-} 6; - conversion ratio R= K/L+M+..... = 0.0914 {+-} 0.0043. (author)

  11. Determination of the conversion coefficient for ambient dose equivalent, H(10), from air kerma measurements

    International Nuclear Information System (INIS)

    Gonzalez J, F.; Alvarez R, J. T.

    2015-09-01

    Namely the operational magnitudes can be determined by the product of a conversion coefficient by exposure air kerma or fluence, etc. In particular in Mexico for the first time is determined the conversion coefficient (Cc) for operational magnitude Environmental Dose Equivalent H(10) by thermoluminescence dosimetry (TLD) technique. First 30 TLD-100 dosimeters are calibrated in terms of air kerma, then these dosimeters are irradiated inside a sphere ICRU type of PMMA and with the aid of theory cavity the absorbed dose in PMMA is determined at a depth of 10 mm within the sphere D PMMA (10), subsequently absorbed dose to ICRU tissue is corrected and the dose equivalent H(10) is determined. The Cc is determined as the ratio of H(10)/K a obtaining a value of 1.20 Sv Gy -1 with a u c = 3.66%, this being consistent with the published value in ISO-4037-3 of 1.20 Sv Gy -1 with a u c = 2%. (Author)

  12. Converting Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2013-01-01

    are suggested: An optimization method for the surface impedances for locally reacting absorbers, the flow resistivity for extendedly reacting absorbers, and the flow resistance for fabrics. With four porous type absorbers, the conversion methods are validated. For absorbers backed by a rigid wall, the surface...... coefficients to random incidence absorption coefficients are proposed. The overestimations of the Sabine absorption coefficient are investigated theoretically based on Miki's model for porous absorbers backed by a rigid wall or an air cavity, resulting in conversion factors. Additionally, three optimizations...... impedance optimization produces the best results, while the flow resistivity optimization also yields reasonable results. The flow resistivity and flow resistance optimization for extendedly reacting absorbers are also found to be successful. However, the theoretical conversion factors based on Miki's model...

  13. Measurement of secondary cosmic radiation and calculation of associated dose conversion coefficients for humans

    International Nuclear Information System (INIS)

    Simmer, Gregor

    2012-01-01

    Due to secondary cosmic radiation (SCR), pilots and flight attendants receive elevated effective doses at flight altitudes. For this reason, since 2003 aircrew members are considered as occupationally exposed, in Germany. This work deals with the calculation of dose conversion coefficients (DCC) for protons, neutrons, electrons, positrons, photons and myons, which are crucial for estimation of effective dose from SCR. For the first time, calculations were performed combining Geant4 - a Monte Carlo code developed at CERN - with the voxel phantoms for the reference female and male published in 2008 by ICRP and ICRU. Furthermore, measurements of neutron fluence spectra - which contribute the major part to the effective dose of SCR - were carried out at the Environmental Research Station Schneefernerhaus (UFS) located at 2650 m above sea level nearby the Zugspitze mountain, Germany. These measured neutron spectra, and additionally available calculated spectra, were then folded with the DCC calculated in this work, and effective dose rates for different heights were calculated.

  14. Observation of changing of the internal conversion coefficient under Moessbauer effect at magnetic transition in Rh-Fe system

    International Nuclear Information System (INIS)

    Ruskov, T.

    1998-01-01

    The magnetic disorder-order transition in the Rh-Fe alloy is studied by conversion electron Moessbauer spectroscopy. The drastic increase of the area under the Moessbauer spectrum at the transition from the paramagnetic to the magnetic state could be explained by diminishing the internal conversion coefficient. Thus our experimental results directly confirm the theory of the collective effect in the system of radiating developed by Yukalov

  15. Validity of the CT to attenuation coefficient map conversion methods

    International Nuclear Information System (INIS)

    Faghihi, R.; Ahangari Shahdehi, R.; Fazilat Moadeli, M.

    2004-01-01

    The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result

  16. Conversion of time-varying Stokes coefficients into mass anomalies at the Earth's surface considering the Earth's oblateness

    Science.gov (United States)

    Ditmar, Pavel

    2018-02-01

    Time-varying Stokes coefficients estimated from GRACE satellite data are routinely converted into mass anomalies at the Earth's surface with the expression proposed for that purpose by Wahr et al. (J Geophys Res 103(B12):30,205-30,229, 1998). However, the results obtained with it represent mass transport at the spherical surface of 6378 km radius. We show that the accuracy of such conversion may be insufficient, especially if the target area is located in a polar region and the signal-to-noise ratio is high. For instance, the peak values of mean linear trends in 2003-2015 estimated over Greenland and Amundsen Sea embayment of West Antarctica may be underestimated in this way by about 15%. As a solution, we propose an updated expression for the conversion of Stokes coefficients into mass anomalies. This expression is based on the assumptions that: (i) mass transport takes place at the reference ellipsoid and (ii) at each point of interest, the ellipsoidal surface is approximated by the sphere with a radius equal to the current radial distance from the Earth's center ("locally spherical approximation"). The updated expression is nearly as simple as the traditionally used one but reduces the inaccuracies of the conversion procedure by an order of magnitude. In addition, we remind the reader that the conversion expressions are defined in spherical (geocentric) coordinates. We demonstrate that the difference between mass anomalies computed in spherical and ellipsoidal (geodetic) coordinates may not be negligible, so that a conversion of geodetic colatitudes into geocentric ones should not be omitted.

  17. Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2014-01-01

    into random incidence absorption coefficients for porous absorbers are investigated. Two optimization-based conversion methods are suggested: the surface impedance estimation for locally reacting absorbers and the flow resistivity estimation for extendedly reacting absorbers. The suggested conversion methods...

  18. The Ångström formula with coefficients having a physical meaning

    International Nuclear Information System (INIS)

    Hinrichsen, K.

    1994-01-01

    A new method is proposed to evaluate the coefficients a and b of the Ångström formula H| H 0 = a + b * s/s 0 . Then, a has the physical meaning of the fraction of diffuse radiation, D, to extraterrestrial radiation, H 0 , and b has the meaning of the fraction of direct radiation, I(1), to H 0 . This is possible at sites where measurements with a shadow band pyranometer are available, in addition to measurements of global radiation, H, and sunshine duration, s. The Ångström formula then gives substantial information about the radiation climate of a site. It is feasible to calculate global radiation, H, on tilted surfaces and planes following the sun's disk, which is essential to evaluate the efficiency of solar energy conversion systems at locations where only measurements of the sunshine duration, s, are available. Thus, it is strongly recommended to replace the regression coefficients a′ and b′ presented in the European Solar Radiation Atlas, which were estimated by least squares approximation. For the site of Hamburg, Germany, it is shown that a ten years interval of data records may be too short to give reliable values of climatological means of D, I(1), H, and s. An increase of direct radiation at Hamburg during the last decade can be detected by the proposed method and may be explained by a decreasing amount of optically active constituents in the air, probable a result of the clean air policy in Germany. (author)

  19. Calculation of conversion coefficients using Chinese adult reference phantoms for air submersion and ground contamination.

    Science.gov (United States)

    Lu, Wei; Qiu, Rui; Wu, Zhen; Li, Chunyan; Yang, Bo; Liu, Huan; Ren, Li; Li, Junli

    2017-03-21

    The effective and organ equivalent dose coefficients have been widely used to provide assessment of doses received by adult members of the public and by workers exposed to environmental radiation from nuclear facilities under normal or accidental situations. Advancements in phantom types, weighting factors, decay data, etc, have led to the publication of newer results in this regard. This paper presents a new set of conversion coefficients for air submersion and ground contamination (with the use of Geant4) for photons from 15 keV to 10 MeV using the Chinese and International Commission on Radiological Protection (ICRP) adult reference male and female phantoms. The radiation fields, except for energy spectrum at low energies, were validated by the data obtained from the Monte Carlo code YURI. The effective dose coefficients of monoenergetic photons, obtained for the ICRP adult reference phantoms, agree well with recently published data for air submersion and ground contamination with a plane source at a depth of 0.5 g cm -2 in soil, but an average difference of 36.5% is observed for ground surface contamination with the abovementioned radiation field. The average differences in organ equivalent dose coefficients between the Chinese and the ICRP adult reference phantoms are within 6% for most organs, but noticeable differences of up to 70% or even higher are found at photon energies below 30 keV under air submersion. The effective dose coefficients obtained with the Chinese adult reference phantoms are greater than those of the ICRP adult reference phantoms above 30 keV and 0.5 MeV for ground contamination and air submersion, respectively; the average differences from the Chinese adult reference phantoms are about 3.6% and 0.4% in the whole energy range with maximum differences of 31.8% and 27.6% at 15 keV for air submersion and ground contamination respectively. These differences are attributed to anatomical discrepancies in overlying tissue mass of an

  20. Standardization and determination of the total internal conversion coefficient of In-111.

    Science.gov (United States)

    Matos, Izabela T; Koskinas, Marina F; Nascimento, Tatiane S; Yamazaki, Ione M; Dias, Mauro S

    2014-05-01

    The standardization of (111)In by means of a 4πβ-γ coincidence system, composed of a proportional counter in 4π geometry, coupled to a 20% relative efficiency HPGe crystal, for measuring gamma-rays is presented. The data acquisition was performed by means of the software coincidence system (SCS) and the activity was determined by the extrapolation technique. Two gamma-ray windows were selected: at 171 keV and 245 keV total absorption peaks, allowing the determination of the total internal conversion coefficient for these two gamma transitions. The results were compared with those available in the literature. © 2013 Published by Elsevier Ltd.

  1. Comparison of effective transverse piezoelectric coefficients e31,f of Pb(Zr,Ti)O3 thin films between direct and converse piezoelectric effects

    Science.gov (United States)

    Tsujiura, Yuichi; Kawabe, Saneyuki; Kurokawa, Fumiya; Hida, Hirotaka; Kanno, Isaku

    2015-10-01

    We evaluated the effective transverse piezoelectric coefficients (e31,f) of Pb(Zr,Ti)O3 (PZT) thin films from both the direct and converse piezoelectric effects of unimorph cantilevers. (001) preferentially oriented polycrystalline PZT thin films and (001)/(100) epitaxial PZT thin films were deposited on (111)Pt/Ti/Si and (001)Pt/MgO substrates, respectively, by rf-magnetron sputtering, and their piezoelectric responses owing to intrinsic and extrinsic effects were examined. The direct and converse |e31,f| values of the polycrystalline PZT thin films were calculated as 6.4 and 11.5-15.0 C/m2, respectively, whereas those of the epitaxial PZT thin films were calculated as 3.4 and 4.6-4.8 C/m2, respectively. The large |e31,f| of the converse piezoelectric property of the polycrystalline PZT thin films is attributed to extrinsic piezoelectric effects. Furthermore, the polycrystalline PZT thin films show a clear nonlinear piezoelectric contribution, which is the same as the Rayleigh-like behavior reported in bulk PZT. In contrast, the epitaxial PZT thin films on the MgO substrate show a piezoelectric response owing to the intrinsic and linear extrinsic effects, and no nonlinear contribution was observed.

  2. Dose conversion coefficients for monoenergetic electrons incident on a realistic human eye model with different lens cell populations.

    Science.gov (United States)

    Nogueira, P; Zankl, M; Schlattl, H; Vaz, P

    2011-11-07

    The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation-the germinative cells-absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.

  3. Dose conversion coefficients for monoenergetic electrons incident on a realistic human eye model with different lens cell populations

    International Nuclear Information System (INIS)

    Nogueira, P; Vaz, P; Zankl, M; Schlattl, H

    2011-01-01

    The radiation-induced posterior subcapsular cataract has long been generally accepted to be a deterministic effect that does not occur at doses below a threshold of at least 2 Gy. Recent epidemiological studies indicate that the threshold for cataract induction may be much lower or that there may be no threshold at all. A thorough study of this subject requires more accurate dose estimates for the eye lens than those available in ICRP Publication 74. Eye lens absorbed dose per unit fluence conversion coefficients for electron irradiation were calculated using a geometrical model of the eye that takes into account different cell populations of the lens epithelium, together with the MCNPX Monte Carlo radiation transport code package. For the cell population most sensitive to ionizing radiation-the germinative cells-absorbed dose per unit fluence conversion coefficients were determined that are up to a factor of 4.8 higher than the mean eye lens absorbed dose conversion coefficients for electron energies below 2 MeV. Comparison of the results with previously published values for a slightly different eye model showed generally good agreement for all electron energies. Finally, the influence of individual anatomical variability was quantified by positioning the lens at various depths below the cornea. A depth difference of 2 mm between the shallowest and the deepest location of the germinative zone can lead to a difference between the resulting absorbed doses of up to nearly a factor of 5000 for electron energy of 0.7 MeV.

  4. Ångström coefficient as a tracer of the continental aerosols

    NARCIS (Netherlands)

    Kuśmierczyk-Michulec, J.T.; Eijk, A.M.J. van

    2007-01-01

    The variation of the extinction coefficient with wavelength can be presented as a power law function with a constant (related to the power factor) known as the Ångström coefficient. When the particle size distribution is dominated by small particles, usually associated with pollution, the Ångström

  5. Estimation of saturation activities for activation experiments in CHARM and CSBF using Fluence Conversion Coefficients

    CERN Document Server

    Guerin, Helene Chloe; Iliopoulou, Elpida; CERN. Geneva. HSE Department

    2017-01-01

    As summer student at CERN, I have been working in the Radiation Protection group for 10 weeks. I worked with the \\textsc{Fluka} Monte Carlo simulation code, using Fluence Conversion Coefficients method to perform simulations to estimate the saturation activities for activation experiments in the \\textsc{CSBF} and the \\textsc{Charm} facility in the East Experimental Area. The provided results will be used to plan a Monte Carlo benchmark in the \\textsc{CSBF} during a beam period at the end of August 2017.

  6. Fluence to absorbed foetal dose conversion coefficients for photons in 50 keV-10 GeV calculated using RPI-P models

    International Nuclear Information System (INIS)

    Taranenko, V.; Xu, X.G.

    2008-01-01

    Radiation protection of pregnant females and the foetus against ionising radiation is of particular importance to radiation protection due to high foetal radiosensitivity. The only available set of foetal conversion coefficients for photons is based on stylised models of simplified anatomy. Using the RPI-P series of pregnant female and foetus models representing 3-, 6- and 9-month gestation, a set of new fluence to absorbed foetal dose conversion coefficients has been calculated. The RPI-P anatomical models were developed using novel 3D geometry modelling techniques. Organ masses were adjusted to agree within 1% with the ICRP reference data for a pregnant female. Monte Carlo dose calculations were carried out using the MCNPX and Penelope codes for external 50 keV-10 GeV photon beams of six standard configurations. The models were voxelised at 3-mm voxel resolution. Conversion coefficients were tabulated for the three gestational periods for the whole foetus and brain. Comparison with previously published data showed deviations up to 120% for the foetal doses at 50 keV. The discrepancy can be primarily ascribed to anatomical differences. Comparison with published data for five major mother organs is also provided for the 3-month model. Since the RPI-P models exhibit a high degree of anatomical realism, the reported dataset is recommended as a reference for radiation protection of the foetus against external photon exposure. (authors)

  7. Establishment of detailed eye model of adult chinese male and dose conversion coefficients calculation under neutron exposure

    International Nuclear Information System (INIS)

    Zhu, Hongyu; Qiu, Rui; Ren, Li; Zhang, Hui; Li, Junli; Wu, Zhen; Li, Chunyan

    2017-01-01

    The human eye lens is sensitive to radiation. ICRP-118 publication recommended a reduction of the occupational annual equivalent dose limit from 150 to 20 mSv, averaged over defined periods of 5 y. Therefore, it is very important to build a detailed eye model for the accurate dose assessment and radiation risk evaluation of eye lens. In this work, a detailed eye model was build based on the characteristic anatomic parameters of the Chinese adult male. This eye model includes seven main structures, which are scleral, choroid, lens, iris, cornea, vitreous body and aqueous humor. The lens was divided into sensitive volume and insensitive volume based on different cell populations. The detailed eye model was incorporated into the converted polygon-mesh version of the Chinese reference adult male whole-body surface model. After the incorporation, dose conversion coefficients for the eye lens were calculated for neutron exposure at AP, PA and LAT geometries with Geant4, the neutron energies were from 0.001 eV to 10 MeV. The calculated lens dose coefficients were compared with those of ICRP-116 publication. Significant differences up to 97.47% were found at PA geometry. This could mainly be attributed to the different geometry characteristic of eye model and parameters of head in different phantom between the present work and ICRP-116 publication. (authors)

  8. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, Ryan P.; Bellamy, Michael B.; Eckerman, Keith F.

    2011-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.

  9. Dose conversion coefficients for neutron exposure to the lens of the human eye

    International Nuclear Information System (INIS)

    Manger, R. P.; Bellamy, M. B.; Eckerman, K. F.

    2012-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10 -9 to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations. (authors)

  10. Effective dose conversion coefficients for X-ray radiographs of the chest and the abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Lima, F.R.A. [Centro regional de Ciencias Nucleares, CRCN/CNEN, Rua Conego Barata, 999, Tamarineira, Recife, PE (Brazil); Kramer, R.; Vieira, J.W.; Khoury, H.J. [Departamento de Energia Nuclear, DEN/UFPE, Cidade Universitaria, Recife, PE (Brazil)]. E-mail: falima@cnen.gov.br

    2004-07-01

    The recently developed MAX (Male Adult voXel) and the FAXht (Female Adult voXel) head and trunk phantoms have been used to calculate organ and tissue equivalent dose conversion coefficients for X-ray radiographs of the chest and the abdomen as a function of source and field parameters, like voltage, filtration, field size, focus-to-skin distance, etc. Based on the equivalent doses to twenty three organs and tissues at risk, the effective dose has been determined and compared with corresponding data for others phantoms. The influence of different radiation transport codes, different tissue compositions and different human anatomies have been investigated separately. (Author)

  11. Effective dose conversion coefficients for X-ray radiographs of the chest and the abdomen

    International Nuclear Information System (INIS)

    Lima, F.R.A.; Kramer, R.; Vieira, J.W.; Khoury, H.J.

    2004-01-01

    The recently developed MAX (Male Adult voXel) and the FAXht (Female Adult voXel) head and trunk phantoms have been used to calculate organ and tissue equivalent dose conversion coefficients for X-ray radiographs of the chest and the abdomen as a function of source and field parameters, like voltage, filtration, field size, focus-to-skin distance, etc. Based on the equivalent doses to twenty three organs and tissues at risk, the effective dose has been determined and compared with corresponding data for others phantoms. The influence of different radiation transport codes, different tissue compositions and different human anatomies have been investigated separately. (Author)

  12. ESTABLISHMENT OF DETAILED EYE MODEL OF ADULT CHINESE MALE AND DOSE CONVERSION COEFFICIENTS CALCULATION UNDER NEUTRON EXPOSURE.

    Science.gov (United States)

    Zhu, Hongyu; Qiu, Rui; Wu, Zhen; Ren, Li; Li, Chunyan; Zhang, Hui; Li, Junli

    2017-12-01

    The human eye lens is sensitive to radiation. ICRP-118 publication recommended a reduction of the occupational annual equivalent dose limit from 150 to 20 mSv, averaged over defined periods of 5 y. Therefore, it is very important to build a detailed eye model for the accurate dose assessment and radiation risk evaluation of eye lens. In this work, a detailed eye model was build based on the characteristic anatomic parameters of the Chinese adult male. This eye model includes seven main structures, which are scleral, choroid, lens, iris, cornea, vitreous body and aqueous humor. The lens was divided into sensitive volume and insensitive volume based on different cell populations. The detailed eye model was incorporated into the converted polygon-mesh version of the Chinese reference adult male whole-body surface model. After the incorporation, dose conversion coefficients for the eye lens were calculated for neutron exposure at AP, PA and LAT geometries with Geant4, the neutron energies were from 0.001 eV to 10 MeV. The calculated lens dose coefficients were compared with those of ICRP-116 publication. Significant differences up to 97.47% were found at PA geometry. This could mainly be attributed to the different geometry characteristic of eye model and parameters of head in different phantom between the present work and ICRP-116 publication. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems

    Directory of Open Access Journals (Sweden)

    Nick Reynaert

    2018-01-01

    Full Text Available Background and purpose: Conversion factors between dose to medium (Dm,m and dose to water (Dw,w provided by treatment planning systems that model the patient as water with variable electron density are currently based on stopping power ratios. In the current paper it will be illustrated that this conversion method is not correct. Materials and methods: Monte Carlo calculations were performed in a phantom consisting of a 2 cm bone layer surrounded by water. Dw,w was obtained by modelling the bone layer as water with the electron density of bone. Conversion factors between Dw,w and Dm,m were obtained and compared to stopping power ratios and ratios of mass-energy absorption coefficients in regions of electronic equilibrium and interfaces. Calculations were performed for 6 MV and 20 MV photon beams. Results: In the region of electronic equilibrium the stopping power ratio of water to bone (1.11 largely overestimates the conversion obtained using the Monte Carlo calculations (1.06. In that region the MC dose conversion corresponds to the ratio of mass energy absorption coefficients. Near the water to bone interface, the MC ratio cannot be determined from stopping powers or mass energy absorption coefficients. Conclusion: Stopping power ratios cannot be used for conversion from Dm,m to Dw,w provided by treatment planning systems that model the patient as water with variable electron density, either in regions of electronic equilibrium or near interfaces. In regions of electronic equilibrium mass energy absorption coefficient ratios should be used. Conversions at interfaces require detailed MC calculations. Keywords: Dose to water, Monte Carlo, Dosimetry, TPS comparison

  14. Pure E2 transitions: A test for BRICC Internal Conversion Coefficients

    International Nuclear Information System (INIS)

    Gerl, J.; Sai, K. Vijay; Sainath, M.; Gowrishankar, R.; Venkataramaniah, K.

    2009-01-01

    The most widely used theoretical internal conversion coefficient (ICC) tables are of Hager and Seltzer (HS), Rosel et al. and BRICC (Band et al. tables using BRICC interpolation code). A rigorous comparison of experimental ICCs with various theoretical tabulations is possible only when a large data on experimental ICCs is available at one place. For this reason, a compilation of all the available experimental ICCs, α T , α K , α L of E2 transitions for a number of elements in the range of 24≤Z≤94 is presented. Listing of experimental data includes 595 datasets corresponding to 505 E2 transitions in 165 nuclei across the nuclear chart. Data with less than 10% experimental uncertainty have been selected for comparison with the theoretical values of Hager and Seltzer, Rosel et al. and BRICC. The relative percentage deviation (%Δ) have been calculated for each of the above theories and the average (%Δ) are estimated. The Band et al. tables, using the BRICC interpolation code are seen to give theoretical ICCs closest to experimental values.

  15. Method for internal conversion coefficients determination by means of a magnetic spectrometer. Application to 129Xe and 77Se

    International Nuclear Information System (INIS)

    Arqueros, F.; Campos, J.

    1986-01-01

    The method used for efficiency calibration of a magnetic electron spectrometer and its applications to conversion electron spectrometry is described. The present results point out that apparatus combining magnetic deflection and semiconductor detection have a nondecreasing interest in nuclear spectrometry for applications where good resolution and large background rejection are both necessary. The present apparatus can be employed with source of relatively low activity, (0.lμCi). The nuclides studied were 129 Xe and 77 Se resulting from 129 Cs and 77 Br decay. The parent nulcides were produced in ISOLDE on line isotope separator at CERN. The efficiency calibration method used for energies higher than 200 keV made use of the well known beta spectrum of 36 Cl. The calibration for low energies was made with Auger electron intensities and suitable conversion lines of 129 Xenon. Results for relative intensities of conversion electron lines and intense gamma lines of 129 Xe and 77 Se are given. From these measurements internal conversion coefficients for transitions of both nuclides were obtained. The results were in agreement with theoretical calculations. (author)

  16. Fluence-to-effective dose conversion coefficients from a Saudi population based phantom for monoenergetic photon beams from 10 keV to 20 MeV

    International Nuclear Information System (INIS)

    Ma, Andy K; Hussein, Mohammed Adel; Altaher, Khalid Mohammed; Farid, Khalid Yousif; Amer, Mamun; Aldhafery, Bander Fuhaid; Alghamdi, Ali A

    2015-01-01

    Fluence-to-dose conversion coefficients are important quantities for radiation protection, derived from Monte Carlo simulations of the radiation particles through a stylised phantom or voxel based phantoms. The voxel phantoms have been developed for many ethnic groups for their accurate reflection of the anatomy. In this study, we used the Monte Carlo code MCNPX to calculate the photon fluence-to-effective dose conversion coefficients with a voxel phantom based on the Saudi Arabian male population. Six irradiation geometries, anterior–posterior (AP), posterior–anterior (PA), left lateral (LLAT), right lateral (RLAT), rotational (ROT) and isotropic (ISO) were simulated for monoenergetic photon beams from 10 keV to 20 MeV. We compared the coefficients with the reference values in ICRP Publication 116. The coefficients in the AP and PA geometries match the reference values to 9% and 12% on average as measured by root mean square while those in the LLAT, RLAT ROT and ISO geometries differ, mostly below, from the reference by 23, 22, 15 and 16%, respectively. The torso of the Saudi phantom is wider than the ICRP reference male phantom and likely to cause more attenuation to the lateral beam. The ICRP reference coefficients serve well for the Saudi male population as conservative estimations for the purpose of radiation protection. (paper)

  17. Reproducibility of The Random Incidence Absorption Coefficient Converted From the Sabine Absorption Coefficient

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Chang, Ji-ho

    2015-01-01

    largely depending on the test room. Several conversion methods for porous absorbers from the Sabine absorption coefficient to the random incidence absorption coefficient were suggested by considering the finite size of a test specimen and non-uniformly incident energy onto the specimen, which turned out...... resistivity optimization outperforms the surface impedance optimization in terms of the reproducibility....

  18. The conversion of exposures due to radon into the effective dose: the epidemiological approach

    Energy Technology Data Exchange (ETDEWEB)

    Beck, T.R. [Federal Office for Radiation Protection, Berlin (Germany)

    2017-11-15

    The risks and dose conversion coefficients for residential and occupational exposures due to radon were determined with applying the epidemiological risk models to ICRP representative populations. The dose conversion coefficient for residential radon was estimated with a value of 1.6 mSv year{sup -1} per 100 Bq m{sup -3} (3.6 mSv per WLM), which is significantly lower than the corresponding value derived from the biokinetic and dosimetric models. The dose conversion coefficient for occupational exposures with applying the risk models for miners was estimated with a value of 14 mSv per WLM, which is in good accordance with the results of the dosimetric models. To resolve the discrepancy regarding residential radon, the ICRP approaches for the determination of risks and doses were reviewed. It could be shown that ICRP overestimates the risk for lung cancer caused by residential radon. This can be attributed to a wrong population weighting of the radon-induced risks in its epidemiological approach. With the approach in this work, the average risks for lung cancer were determined, taking into account the age-specific risk contributions of all individuals in the population. As a result, a lower risk coefficient for residential radon was obtained. The results from the ICRP biokinetic and dosimetric models for both, the occupationally exposed working age population and the whole population exposed to residential radon, can be brought in better accordance with the corresponding results of the epidemiological approach, if the respective relative radiation detriments and a radiation-weighting factor for alpha particles of about ten are used. (orig.)

  19. The conversion of exposures due to radon into the effective dose: the epidemiological approach

    International Nuclear Information System (INIS)

    Beck, T.R.

    2017-01-01

    The risks and dose conversion coefficients for residential and occupational exposures due to radon were determined with applying the epidemiological risk models to ICRP representative populations. The dose conversion coefficient for residential radon was estimated with a value of 1.6 mSv year -1 per 100 Bq m -3 (3.6 mSv per WLM), which is significantly lower than the corresponding value derived from the biokinetic and dosimetric models. The dose conversion coefficient for occupational exposures with applying the risk models for miners was estimated with a value of 14 mSv per WLM, which is in good accordance with the results of the dosimetric models. To resolve the discrepancy regarding residential radon, the ICRP approaches for the determination of risks and doses were reviewed. It could be shown that ICRP overestimates the risk for lung cancer caused by residential radon. This can be attributed to a wrong population weighting of the radon-induced risks in its epidemiological approach. With the approach in this work, the average risks for lung cancer were determined, taking into account the age-specific risk contributions of all individuals in the population. As a result, a lower risk coefficient for residential radon was obtained. The results from the ICRP biokinetic and dosimetric models for both, the occupationally exposed working age population and the whole population exposed to residential radon, can be brought in better accordance with the corresponding results of the epidemiological approach, if the respective relative radiation detriments and a radiation-weighting factor for alpha particles of about ten are used. (orig.)

  20. Calculation of conversion coefficients of dose of a computational anthropomorphic simulator sit exposed to a plane source

    International Nuclear Information System (INIS)

    Santos, William S.; Carvalho Junior, Alberico B. de; Pereira, Ariana J.S.; Santos, Marcos S.; Maia, Ana F.

    2011-01-01

    In this paper conversion coefficients (CCs) of equivalent dose and effective in terms of kerma in the air were calculated suggested by the ICRP 74. These dose coefficients were calculated considering a plane radiation source and monoenergetic for a spectrum of energy varying from 10 keV to 2 MeV. The CCs were obtained for four geometries of irradiation, anterior-posterior, posterior-anterior, lateral right side and lateral left side. It was used the radiation transport code Visual Monte Carlo (VMC), and a anthropomorphic simulator of sit female voxel. The observed differences in the found values for the CCs at the four irradiation sceneries are direct results of the body organs disposition, and the distance of these organs to the irradiation source. The obtained CCs will be used for estimative more precise of dose in situations that the exposed individual be sit, as the normally the CCs available in the literature were calculated by using simulators always lying or on their feet

  1. Laser source with high pulse energy at 3-5 μm and 8-12 μm based on nonlinear conversion in ZnGeP2

    Science.gov (United States)

    Lippert, Espen; Fonnum, Helge; Haakestad, Magnus W.

    2014-10-01

    We present a high energy infrared laser source where a Tm:fiber laser is used to pump a high-energy 2-μm cryogenically cooled Ho:YLF laser. We have achieved 550 mJ of output energy at 2.05 μm, and through non-linear conversion in ZnGeP2 generated 200 mJ in the 3-5-μm range. Using a numerical simulation tool we have also investigated a setup which should generate more than 70 mJ in the 8-12-μm range. The conversion stage uses a master-oscillator-power-amplifier architecture to enable high conversion efficiency and good beam quality.

  2. Hp(3)/Φ conversion coefficients for neutrons: discussion on the basis of the new ICRP recommended limit for the eye lens

    International Nuclear Information System (INIS)

    Ferrari, P.; Gualdrini, G.; Fantuzzi, E.; Tanner, R.

    2014-01-01

    The new recommendation issued by the International Commission on Radiological Protection (ICRP) introducing a 20-mSv annual dose limit for the eye lens stimulated an interesting debate among the radiation protection community. In the present work the problem of estimating H p (3) for neutron realistic workplace spectra is treated, employing the recently published H p (3)/Φ conversion coefficients with the aim of establishing a workplace-dependent relationship between H p (10) and H p (3). The results demonstrate that, whilst the two quantities can differ by less than 10 %, in general, H p (10) cannot be considered a conservative estimate of H p (3). The present study was conducted to find out whether it is possible to derive H p (3) from H p (10) measurements/determinations in neutron workplace fields using the relationship that can be established between the conversion coefficients H p (3)/Φ and H p (10)/Φ evaluated for monoenergetic neutron beams. Several real cases, taken from the IAEA neutron source compendium, were investigated and, in general, it can be conclude that H p (10) is seldom a conservative estimate of H p (3) (only at 0 deg. and in one case, among the treated spectra, H p (10)/Φ is higher than H p (3)/Φ). Indeed, care should be taken if one tries to derive directly such a correction factor from tabulations of neutron monoenergetic plots of conversion coefficients, on the basis of the mean energy, because in case of really degraded spectra (as in the heavy shielded situation) the mean energy, as expected, could be a too rough a parameter. However, in general, for 0 deg., antero-posterior irradiation condition, which is expected to be a quite common working condition, H p (10) underestimation is of the order of 10 % thus, at least, a correction factor of 1.1 should be applied to H p (10) in order to estimate the 'corresponding' H p (3). For irradiation conditions far from the normal incidence for which the underestimation can be as high as 60

  3. Measurement of conversion coefficients in 208Tl

    International Nuclear Information System (INIS)

    Wendling, F.

    1976-06-01

    A electron spectrometer composed by a Li drifted Si detector and a uniform magnetic field was constructed. The magnetic field is used to focus the electrons on the detector and to filter the other radiations. After the construction the instrument was calibrated in absolute eficience and was used together with a Ge(Li) spectrometer also calibrated, in the measurement of internal conversion coeficients of the 433 and 453 keV transitions in 208 Tl [pt

  4. Proton and photon absorbed-dose conversion coefficients for embryo and foetus from top-down irradiation geometry

    International Nuclear Information System (INIS)

    Chen, J.

    2007-01-01

    Absorbed-dose conversion coefficients are calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months when the mother's body is exposed to protons and photons from top-down (TOP) direction. It provides data sets in addition to other standard irradiation geometries published previously. The TOP-irradiation geometry is considered here, because high-energy particles are often peaked from the TOP direction onboard aircraft. The results show that absorbed-doses from high-energy particles could be underestimated significantly if isotropic (ISO) irradiation geometry is assumed. For protons of 100 GeV, absorbed-doses from TOP irradiation are ∼2.3-2.9 times higher than the doses from ISO irradiation for different foetal ages. For 10 GeV photons, foetal doses from TOP irradiation are ∼6.8-12 times higher than the doses from ISO irradiation. The coefficients from TOP-irradiation geometry are given in wide energy ranges, from 100 MeV to 100 GeV for protons and from 50 V to 10 GeV for photons. They can, therefore, be used in various applications whenever exposure from the TOP-irradiation direction is concerned. (authors)

  5. Variation in reference crop evapotranspiration caused by the Ångström-Prescott coefficient

    DEFF Research Database (Denmark)

    Liu, Xiaoying; Mei, Xurong; Li, Yuzhong

    2009-01-01

    these relations, which was (1) determine if calibration is needed or not for a given location; (2) estimate one of the A-P coefficients, either a or b if calibration is needed; (3) estimate the remaining coefficient using relations of (a + b) due to its higher coefficient of determination. In summary, we have...... associated with using un-calibrated Ångström-Prescott (A-P) coefficients. We first calibrated the coefficients using long-term data records from 34 sites in the Yellow River basin in China, and then applied these coefficients to estimate short wave irradiance (Rs) and ET0 at 16 sites to evaluate...... the difference in ET0 between the FAO recommended and the locally calibrated. We found that the direct use of the FAO recommended coefficients significantly affected the estimation of ET0 at most sites, which differed from -3% to 15% at daily scale and from -4% to 16% at monthly scale from the locally calibrated...

  6. Fluence-to-Absorbed Dose Conversion Coefficients for Use in Radiological Protection of Embryo and Foetus Against External Exposure to Muons from 20MeV to 50GeV

    International Nuclear Information System (INIS)

    Chen Jing

    2008-01-01

    This study used the Monte-Carlo code MCNPX to determine mean absorbed doses to the embryo and foetus when the mother is exposed to external muon fields. Monoenergetic muons ranging from 20 MeV to 50 GeV were considered. The irradiation geometries include anteroposterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT), isotropic (ISO), and top-down (TOP). At each of these irradiation geometries, absorbed doses to the foetal body were calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months, respectively. Muon fluence-to-absorbed-dose conversion coefficients were derived for the four prenatal ages. Since such conversion coefficients are yet unknown, the results presented here fill a data gap

  7. Thermoelectric conversion efficiency in IV-VI semiconductors with reduced thermal conductivity

    Directory of Open Access Journals (Sweden)

    Akihiro Ishida

    2015-10-01

    Full Text Available Mid-temperature thermoelectric conversion efficiencies of the IV-VI materials were calculated under the Boltzmann transport theory of carriers, taking the Seebeck, Peltier, and Thomson effects into account. The conversion efficiency was discussed with respect to the lattice thermal conductivity, keeping other parameters such as Seebeck coefficient and electrical conductivity to the same values. If room temperature lattice thermal conductivity is decreased up to 0.5W/mK, the conversion efficiency of a PbS based material becomes as high as 15% with the temperature difference of 500K between 800K and 300K.

  8. Preparation of 114mIn low energy conversion electron sources

    International Nuclear Information System (INIS)

    Wrede, C.; Filippone, B.W.; Garcia, A.; Harper, G.C.; Lassell, S.; Liu, J.; Mendenhall, M.P.; Palmer, A.S.C.; Pattie, R.W.; Will, D.I.; Young, A.R.

    2011-01-01

    Highlights: → Controlled ion implantation of In-113 into thin Al substrate. → Production of In-114m (half life = 50 days) by neutron irradiation. → Use of In-114m as a source of electron lines and continuum for calibrations. → Source reactivation by short neutron irradiation. -- Abstract: The preparation of 114m In sources of conversion electrons in the energy range 162-190 keV and β continuum with a 1989 keV endpoint via ion implantation of 113 In into Al substrates and subsequent irradiation by thermal and epi-thermal neutrons in a nuclear reactor is described.

  9. The local skin dose conversion coefficients of electrons, protons and alpha particles calculated using the Geant4 code.

    Science.gov (United States)

    Zhang, Bintuan; Dang, Bingrong; Wang, Zhuanzi; Wei, Wei; Li, Wenjian

    2013-10-01

    The skin tissue-equivalent slab reported in the International Commission on Radiological Protection (ICRP) Publication 116 to calculate the localised skin dose conversion coefficients (LSDCCs) was adopted into the Monte Carlo transport code Geant4. The Geant4 code was then utilised for computation of LSDCCs due to a circular parallel beam of monoenergetic electrons, protons and alpha particles electrons and alpha particles are found to be in good agreement with the results using the MCNPX code of ICRP 116 data. The present work thus validates the LSDCC values for both electrons and alpha particles using the Geant4 code.

  10. Linear mode conversion in a toroidal plasma

    International Nuclear Information System (INIS)

    Hellsten, T.

    1980-05-01

    Linear mode conversion at the perpendicular ion cyclotron resonance has been treated for an axially symmetric toroidal plasma. The mode conversion appears between a fast electromagnetic wave and a slow-quasi electrostatic wave, due to finite electron inertia. The problem reduces to the Orr-Sommerfeld equation where the coefficients determining the reflectron, transmission and conversion are functions of the arc length along a poloidal intersection of the resonance surface. These coefficients can be determined from eigenfunctions of an ordinary differential equation. (author)

  11. Determination of the conversion coefficient for ambient dose equivalent, H(10), from air kerma measurements; Determinacion del coeficiente de conversion para la dosis equivalente ambiental, H*(10), a partir de mediciones de kerma en aire

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez J, F. [UNAM, Facultad de Ciencias, Circuito Exterior, Ciudad Universitaria, 04510 Ciudad de Mexico (Mexico); Alvarez R, J. T., E-mail: trinidad.alvarez@inin.gob.mx [ININ, Departamento de Metrologia de Radiaciones Ionizantes, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    Namely the operational magnitudes can be determined by the product of a conversion coefficient by exposure air kerma or fluence, etc. In particular in Mexico for the first time is determined the conversion coefficient (Cc) for operational magnitude Environmental Dose Equivalent H(10) by thermoluminescence dosimetry (TLD) technique. First 30 TLD-100 dosimeters are calibrated in terms of air kerma, then these dosimeters are irradiated inside a sphere ICRU type of PMMA and with the aid of theory cavity the absorbed dose in PMMA is determined at a depth of 10 mm within the sphere D{sub PMMA}(10), subsequently absorbed dose to ICRU tissue is corrected and the dose equivalent H(10) is determined. The Cc is determined as the ratio of H(10)/K{sub a} obtaining a value of 1.20 Sv Gy{sup -1} with a u{sub c}= 3.66%, this being consistent with the published value in ISO-4037-3 of 1.20 Sv Gy{sup -1} with a u{sub c}= 2%. (Author)

  12. Fluence-to-absorbed dose conversion coefficients for use in radiological protection of embryo and foetus against external exposure to protons from 100 MeV to 100 GeV

    International Nuclear Information System (INIS)

    Chen, J.

    2006-01-01

    In the literature, no conversion coefficients are available for use in radiological protection of embryo and foetus against external exposure to protons. This study used the Monte Carlo code MCNPX to determine mean absorbed doses to the embryo and foetus when the mother is exposed to proton fields. Monoenergetic protons ranging from 100 MeV to 100 GeV were considered. The irradiation geometries include antero-posterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT) and isotropic (ISO). At each of these standard irradiation geometries, absorbed doses to the foetal brain and body were calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months. Proton fluence-to-absorbed dose conversion coefficients were derived for the four prenatal ages. (authors)

  13. Four-body conversion of atomic helium ions

    International Nuclear Information System (INIS)

    de Vries, C.P.; Oskam, H.J.

    1980-01-01

    The conversion of atomic helium ions into molecular ions was studied in pure helium and in helium-neon mixtures containing between 0.1 at. % and 50 at. % neon. The experiments showed that the termolecular conversion reaction, He + +2He → He 2 + +He, is augmented by the four-body conversion reaction He + +3He → products, where the products could include either He 2 + or He 3 + ions. Conversion rate coefficients of (5.7 +- 0.8) x 10 -32 cm 6 sec -1 and (2.6 +- 0.4) x 10 -49 cm 9 sec -1 were found for the termolecular and four-body conversion reactions, respectively. In addition, rate coefficients for the following Ne + conversion reactions were measured: Ne + +He+He → (HeNe) + +He, (2.3 +- 0.1) x 10 -32 cm 6 sec -1 ; Ne + +He+Ne → (HeNe) + +Ne or Ne 2 + +He, (8.0 +- 0.8) x 10 -32 cm 6 sec -1 ; and Ne + +Ne+Ne → Ne 2 + +Ne, (5.1 +- 0.3) x 10 -32 cm 6 sec -1 . All rate coefficients are at a gas temperature of 295 K

  14. Monopole conversion hidden by penetration effect in magnetic dipole transitions

    International Nuclear Information System (INIS)

    Bikit, I.; Anichin, I.; Marinkov, L.

    1977-01-01

    The 191 keV 197 Au nad 340 keV 233 U transitions are investigated and the effect of penetration into the M1-component is accounted for. Theoretical internal conversion coefficients (ICC) and electron parameters to account for the penetration effect have been obtained by interpolating the data of the Hager and Zeltzer tables. The ICC values and ratios are analyzed under the assumption that the 191 keV 197 Au transition has multipolarities M1 + E2 and E 0 +M1. A common overlapping occurs when the nuclear penetration parameter lambda for magnetic dipole transition is lambda = 34.2+-2.2. For the 340 keV 233 U transition the ICC has been found to equal αk=0.69+-0.07, and the relative conversion-line intensities have been determined. It is concluded that the 191 keV 197 Au nad 340 keV 233 U transitions involve an electric monopole component concealed by the penetration effect in the M1-conversion. The matrix elements of the E0-transition have been evaluated

  15. Cyclic AMP is a key regulator of M1 to M2a phenotypic conversion of microglia in the presence of Th2 cytokines.

    Science.gov (United States)

    Ghosh, Mousumi; Xu, Yong; Pearse, Damien D

    2016-01-13

    Microglia and macrophages play a central role in neuroinflammation. Pro-inflammatory cytokines trigger their conversion to a classically activated (M1) phenotype, sustaining inflammation and producing a cytotoxic environment. Conversely, anti-inflammatory cytokines polarize the cells towards an alternatively activated (M2), tissue reparative phenotype. Elucidation of the signal transduction pathways involved in M1 to M2 phenotypic conversion may provide insight into how the innate immune response can be harnessed during distinct phases of disease or injury to mediate neuroprotection and neurorepair. Microglial cells (cell line and primary) were subjected to combined cyclic adenosine monophosphate (cyclic AMP) and IL-4, or either alone, in the presence of pro-inflammatory mediators, lipopolysaccharide (LPS), or tumor necrosis factor-α (TNF-α). Their effects on the expression of characteristic markers for M1 and M2 microglia were assessed. Similarly, the M1 and M2 phenotypes of microglia and macrophages within the lesion site were then evaluated following a contusive spinal cord injury (SCI) to the thoracic (T8) spinal cord of rats and mice when the agents were administered systemically. It was demonstrated that cyclic AMP functions synergistically with IL-4 to promote M1 to M2 conversion of microglia in culture. The combination of cyclic AMP and IL-4, but neither alone, induced an Arg-1(+)/iNOS(-)cell phenotype with concomitant expression of other M2-specific markers including TG2 and RELM-α. M2-converted microglia showed ameliorated production of pro-inflammatory cytokines (TNF-α and IP-10) and reactive oxygen species, with no alteration in phagocytic properties. M2a conversion required protein kinase A (PKA), but not the exchange protein directly activated by cyclic AMP (EPAC). Systemic delivery of cyclic AMP and IL-4 after experimental SCI also promoted a significant M1 to M2a phenotypic change in microglia and macrophage population dynamics in the lesion

  16. Estimated fluence-to-absorbed dose conversion coefficients for use in radiological protection of embryo and foetus against external exposure to photons from 50 keV to 10 GeV

    International Nuclear Information System (INIS)

    Chen, J.

    2006-01-01

    In the literature, no conversion coefficients are available for use in radiological protection of the embryo and foetus against external exposure to photons. This study used the Monte-Carlo code MCNPX to determine mean absorbed doses to the embryo and foetus when the mother is exposed to external photon fields. Monoenergetic photons ranging from 50 keV to 10 GeV were considered. The irradiation geometries included antero-posterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT), and isotropic (ISO). At each of these standard irradiation geometries, absorbed doses to the foetal brain and body were calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months. Photon fluence-to-absorbed-dose conversion coefficients were estimated for the four prenatal ages. (authors)

  17. High energy photon reference for radiation protection: technical design of the LINAC beam and ionization chambers; and calculation of monoenergetic conversion coefficients

    Directory of Open Access Journals (Sweden)

    Dusciac D.

    2016-01-01

    Full Text Available In this work, we present the results of the first part of a research project aimed at offering a complete response to dosimeters providers and nuclear physicists’ demands for high-energy (6 – 9 MeV photon beams for radiation protection purposes. Classical facilities allowing the production of high-energy photonic radiation (proton accelerators, nuclear reactors are very rare and need large investment for development and use. A novel solution is proposed, consisting in the use of a medical linear accelerator, allowing a significant decrease of all costs.Using Monte Carlo simulations (MCNP5 and PENELOPE codes, a specifically designed electron-photon conversion target allowing for obtaining a high energy photon beam (with an average energy weighted by fluence of about 6 MeV has been built for radiation protection purposes. Due to the specific design of the target, this “realistic” radiation protection high-energy photon beam presents a uniform distribution of air kerma rate at a distance of 1 m, over a 30 × 30 cm2 surface. Two graphite cavity ionizing chambers for ionometric measurements have been built. For one of these chambers, the charge collection volume has been measured allowing for its use as a primary standard. The second ionizing chamber is used as a transfer standard; as such it has been calibrated in a 60Co beam, and in the high energy photon beam for radiation protection.The measurements with these ionizing chambers allowed for an evaluation of the air kerma rate in the LINAC based high-energy photon beam for radiation protection: the values cover a range between 36 mGy/h and 210 mGy/h, compatible with radiation protection purposes.Finally, using Monte Carlo simulations, conversion coefficients from air kerma to dose equivalent quantities have been calculated in the range between 10 keV and 22.4 MeV, for the spectral distribution of the fluence corresponding to the beam produced by the linear accelerator of the LNE-LNHB.

  18. Calculation of conversion coefficients Hp(3)/K air using the PENELOPE Monte Carlo code and comparison with MCNP calculation results

    International Nuclear Information System (INIS)

    Daures, J.; Gouriou, J.; Bordy, J.M.

    2010-01-01

    The authors report calculations performed using the MNCP and PENELOPE codes to determine the Hp(3)/K air conversion coefficient which allows the Hp(3) dose equivalent to be determined from the measured value of the kerma in the air. They report the definition of the phantom, a 20 cm diameter and 20 cm high cylinder which is considered as representative of a head. Calculations are performed for an energy range corresponding to interventional radiology or cardiology (20 keV-110 keV). Results obtained with both codes are compared

  19. Preparation of {sup 114m}In low energy conversion electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Wrede, C., E-mail: wrede@uw.ed [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA 98195 (United States); Filippone, B.W. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, California 91125 (United States); Garcia, A.; Harper, G.C. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA 98195 (United States); Lassell, S. [Department of Nuclear Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States); Liu, J. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, California 91125 (United States); Department of Physics, Shanghai Jiao Tong University, Shanghai 200240 (China); Mendenhall, M.P. [Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, California 91125 (United States); Palmer, A.S.C. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA 98195 (United States); Pattie, R.W. [Department of Physics, North Carolina State University, Raleigh, North Carolina 27695 (United States); Will, D.I. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA 98195 (United States); Young, A.R. [Department of Physics, North Carolina State University, Raleigh, North Carolina 27695 (United States)

    2011-05-15

    Highlights: {yields} Controlled ion implantation of In-113 into thin Al substrate. {yields} Production of In-114m (half life = 50 days) by neutron irradiation. {yields} Use of In-114m as a source of electron lines and continuum for calibrations. {yields} Source reactivation by short neutron irradiation. -- Abstract: The preparation of {sup 114m}In sources of conversion electrons in the energy range 162-190 keV and {beta} continuum with a 1989 keV endpoint via ion implantation of {sup 113}In into Al substrates and subsequent irradiation by thermal and epi-thermal neutrons in a nuclear reactor is described.

  20. Internal conversion theory of gamma radiation in unfilled atomic shells

    International Nuclear Information System (INIS)

    Anderson, Eh.M.; Trusov, V.F.; Ehglajs, M.O.

    1980-01-01

    The internal conversion theory of gamma radiation in unfilled shells, when the atom is in a state with certain energy and momentum, is considered. A formula for the conversion coefficient between the atom and ion levels is obtained. This coefficient turns to be dependent on genealogic characteristics of the atom. It is discussed when the conversion coefficients are proportional to the numbers of filling subshells in the atom. Exact calculations have been carried out in the multiconfigurational approximation taking into account intermediate coupling for the d-shell of the Fe atom Single-electron radial wave functions have been calculated on the basis of the relativistic method of the Hartree-Fock-Dirak self-consistent field. Conversion coefficients on certain subshells as well as submatrix elements of the production operator are calculated. The electric coefficient of internal conversion (CIC) in the calculation for one electron does not depend on spin orientation. That is why the electric CIC from the level will not depend on filling number distribution by subshells. For magnetic CIC the dependence on the atom state is significant. Using multiconfiguration basis for calculating energy matrix and its succeeding diagonalization means the account of the intermediate coupling type, which takes place for the unfilled shells

  1. A conversion method of air-kerma from the primary, scatter and leakage radiations to ambient dose equivalent for calculating the mamography x-ray shielding barrier

    International Nuclear Information System (INIS)

    Kharrati, H.

    2005-01-01

    The primary, scatter, and leakage doses(in Gy), which constitute the data base for calculating shielding requirements for x-ray facilities, are often converted to the equivalent dose (in sievert) by using a constant of conversion of 1.145Sv/Gy. This constant is used for diagnostic radiology as well as for mammography spectra, and is derived by considering an exposure of 1 R corresponds to an air kerma of 8.73 m Gy, which renders by tradition an equivalent dose of 10 mSv. However, this conversion does not take into account the energy dependence of the conversion coefficients relating air kerma to the equivalent dose as described in ICRU report. Moreover, current radiation protection standards propose the use of the quantity ambient dose equivalent in order to qualify the efficiently of given radiation shielding. Therefore, in this study, a new approach has been introduced for derivation ambient dose equivalent from air kerma to calculate shielding requirements in mammography facilities. This new approach has been used to compute the conversion coefficients relating air kerma to ambient dose equivalent for mammography reference beam series of the Netherlands Metrology Institute Van Swinden Laboratorium (NMi), National Institute of Standards and Technology (NIST), and International Atomic Energy Agency (AIEA) laboratories. The calculation has been performed by the means of two methods which show a maximum deviation less than 10%2 for the primary, scatter, and leakage radiations. The results show that the conversion coefficients vary from 0.242 Sv/ Gy to 0.692 Sv/Gy with an average value of 0.436 Sv/Gy for the primary and the scatter radiations, and form 0.156 Sv/Gy to 1.329 Sv/Gy with an average value of 0.98 Sv/Gy for the leakage radiation. Simpkin et al. using an empirical approach propose a conversion value of 0.50 Sv/Gy for the mammography x-ray spectra. This value approximately coincides with the average conversion value of 0.436 Sv/Gy obtained in this work for

  2. Monte Carlo Method in the calculate of conversion coefficients for dose in children's organs and tissues subjected to dentistric radiography

    International Nuclear Information System (INIS)

    Loureiro, E.C.M.; Khoury, H.; Lima, F.R.A.

    1998-01-01

    The increasing utilization of oral X-rays, specially in youngsters and children, prompts the assessment of equivalent doses in their organs and tissues. With this purpose, Monte Carlo code was adopted to simulate an X-ray source irradiating phantoms of the MIRD-5 type with different ages (10, 15 and 40 years old) to calculate the conversion coefficients which transform the exposure at skin to equivalent doses at several organs and tissues of interest. In order to check the computer program, simulations were performed for adult patients using the original code (ADAM,FOR developed by GSF Germany) and the adapted program (MCDRO,PAS). Good agreement between results obtained by both programs was observed. Applications to incisive, canine and molar teeth were simulated. The conversion factors were calculated for the following organs and tissues: thyroid, active bone marrow (head and whole body), bone (facial skeleton, cranium and whole body), skin (head and whole body) and crystalline. Based on the obtained results, it follows that the younger the patient and the langer the field area, the higher the doses in assessed organs and tissues

  3. Conversion coefficients for determination of dispersed photon dose during radiotherapy: NRUrad input code for MCNP.

    Science.gov (United States)

    Shahmohammadi Beni, Mehrdad; Ng, C Y P; Krstic, D; Nikezic, D; Yu, K N

    2017-01-01

    Radiotherapy is a common cancer treatment module, where a certain amount of dose will be delivered to the targeted organ. This is achieved usually by photons generated by linear accelerator units. However, radiation scattering within the patient's body and the surrounding environment will lead to dose dispersion to healthy tissues which are not targets of the primary radiation. Determination of the dispersed dose would be important for assessing the risk and biological consequences in different organs or tissues. In the present work, the concept of conversion coefficient (F) of the dispersed dose was developed, in which F = (Dd/Dt), where Dd was the dispersed dose in a non-targeted tissue and Dt is the absorbed dose in the targeted tissue. To quantify Dd and Dt, a comprehensive model was developed using the Monte Carlo N-Particle (MCNP) package to simulate the linear accelerator head, the human phantom, the treatment couch and the radiotherapy treatment room. The present work also demonstrated the feasibility and power of parallel computing through the use of the Message Passing Interface (MPI) version of MCNP5.

  4. Comparison of conversion coefficients for equivalent dose in terms of air kerma using a sitting and standing female adult voxel simulators exposure to photons in antero-posterior irradiation geometry

    International Nuclear Information System (INIS)

    Cavalcante, F.R.; Galeano, D.C.; Carvalho Júnior, A.B.; Hunt, J.

    2014-01-01

    Due to the difficulty in implementing invasive techniques for calculations of dose for some exposure scenarios, computational simulators have been created to represent as realistically as possible the structures of the human body and through radiation transport simulations to obtain conversion coefficients (CCs) to estimate dose. In most published papers simulators are implemented in the standing posture and this may not describe a real scenario of exposure. In this work we developed exposure scenarios in the Visual Monte Carlo (VMC) code using a female simulator in standing and sitting postures. The simulator was irradiated in the antero-posterior (AP) geometry by a plane source of monoenergetic photons with energy from 10 keV to 2 MeV. The conversion coefficients for equivalent dose in terms of air kerma (H T /K air ) were calculated for both scenarios and compared. The results show that the percentage difference of CCs for the organs of the head and thorax was not significant (less than 5%) since the anatomic position of the organs is the same in both postures. The percentage difference is more significant to the ovaries (71% for photon energy of 20 keV), to the bladder (39% at 60 keV) and to the uterus (37% at 100 keV) due to different processes of radiation interactions in the legs of the simulator when its posture is changed. For organs and tissues that are distributed throughout the entire body, such as bone (21% at 100 keV) and muscle (30% at 80 keV) the percentage difference of CCs reflects a reduction of interaction of photons with the legs of the simulator. Therefore, the calculation of conversion coefficients using simulators in the sitting posture is relevant for a more accurate dose estimation in real exposures to radiation. - Highlights: ► Scenarios of external photon exposures were performed in VMC code. ► The FAX simulator was irradiated in sitting and standing postures. ► The irradiation geometry used was the antero-posterior (AP). ► The

  5. Temperature dependence of mode conversion in warm, unmagnetized plasmas with a linear density profile

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Dae Jung; Lee, Dong-Hun [School of Space Research, Kyung Hee University, Yongin (Korea, Republic of); Kim, Kihong [Division of Energy Systems Research, Ajou University, Suwon (Korea, Republic of)

    2013-06-15

    We study theoretically the linear mode conversion between electromagnetic waves and Langmuir waves in warm, stratified, and unmagnetized plasmas, using a numerically precise calculation based on the invariant imbedding method. We verify that the principle of reciprocity for the forward and backward mode conversion coefficients holds precisely regardless of temperature. We also find that the temperature dependence of the mode conversion coefficient is substantially stronger than that previously reported. Depending on the wave frequency and the incident angle, the mode conversion coefficient is found to increase or decrease with the increase of temperature.

  6. Measurement of secondary cosmic radiation and calculation of associated dose conversion coefficients for humans; Messung sekundaerer kosmischer Strahlung und Berechnung der zugehoerigen Dosiskonversionskoeffizienten fuer den Menschen

    Energy Technology Data Exchange (ETDEWEB)

    Simmer, Gregor

    2012-04-11

    Due to secondary cosmic radiation (SCR), pilots and flight attendants receive elevated effective doses at flight altitudes. For this reason, since 2003 aircrew members are considered as occupationally exposed, in Germany. This work deals with the calculation of dose conversion coefficients (DCC) for protons, neutrons, electrons, positrons, photons and myons, which are crucial for estimation of effective dose from SCR. For the first time, calculations were performed combining Geant4 - a Monte Carlo code developed at CERN - with the voxel phantoms for the reference female and male published in 2008 by ICRP and ICRU. Furthermore, measurements of neutron fluence spectra - which contribute the major part to the effective dose of SCR - were carried out at the Environmental Research Station Schneefernerhaus (UFS) located at 2650 m above sea level nearby the Zugspitze mountain, Germany. These measured neutron spectra, and additionally available calculated spectra, were then folded with the DCC calculated in this work, and effective dose rates for different heights were calculated.

  7. Monte Carlo determination of the conversion coefficients Hp(3)/Ka in a right cylinder phantom with 'PENELOPE' code. Comparison with 'MCNP' simulations.

    Science.gov (United States)

    Daures, J; Gouriou, J; Bordy, J M

    2011-03-01

    This work has been performed within the frame of the European Union ORAMED project (Optimisation of RAdiation protection for MEDical staff). The main goal of the project is to improve standards of protection for medical staff for procedures resulting in potentially high exposures and to develop methodologies for better assessing and for reducing, exposures to medical staff. The Work Package WP2 is involved in the development of practical eye-lens dosimetry in interventional radiology. This study is complementary of the part of the ENEA report concerning the calculations with the MCNP-4C code of the conversion factors related to the operational quantity H(p)(3). In this study, a set of energy- and angular-dependent conversion coefficients (H(p)(3)/K(a)), in the newly proposed square cylindrical phantom made of ICRU tissue, have been calculated with the Monte-Carlo code PENELOPE and MCNP5. The H(p)(3) values have been determined in terms of absorbed dose, according to the definition of this quantity, and also with the kerma approximation as formerly reported in ICRU reports. At a low-photon energy (up to 1 MeV), the two results obtained with the two methods are consistent. Nevertheless, large differences are showed at a higher energy. This is mainly due to the lack of electronic equilibrium, especially for small angle incidences. The values of the conversion coefficients obtained with the MCNP-4C code published by ENEA quite agree with the kerma approximation calculations obtained with PENELOPE. We also performed the same calculations with the code MCNP5 with two types of tallies: F6 for kerma approximation and *F8 for estimating the absorbed dose that is, as known, due to secondary electrons. PENELOPE and MCNP5 results agree for the kerma approximation and for the absorbed dose calculation of H(p)(3) and prove that, for photon energies larger than 1 MeV, the transport of the secondary electrons has to be taken into account.

  8. A new fifth parameter for transverse isotropy III: reflection and transmission coefficients

    Science.gov (United States)

    Kawakatsu, Hitoshi

    2018-04-01

    The effect of the newly defined fifth parameter, ηκ, of transverse anisotropy to the reflection and transmission coefficients, especially for P-to-S and S-to-P conversion coefficients, is examined. While ηκ systematically affects the P-to-S and S-to-P conversions, in the incidence angle range of the practical interest of receiver function studies, the effect may be asymmetric in a sense that P-wave receiver function is affected more than S-receiver function in terms of amplitude. This asymmetry may help resolving ηκ via extensive receiver function analysis. It is also found that P-wave anisotropy significantly influences P-to-S and S-to-P conversion coefficients that complicates the interpretation of receiver functions, because, for isotropic media, we typically attribute the primary receiver function signals to S-wave velocity changes but not to P-wave changes.

  9. Towards the reanalysis of void coefficients measurements at proteus for high conversion light water reactor lattices

    Energy Technology Data Exchange (ETDEWEB)

    Hursin, M.; Koeberl, O.; Perret, G. [Paul Scherrer Institut PSI, 5232 Villigen (Switzerland)

    2012-07-01

    High Conversion Light Water Reactors (HCLWR) allows a better usage of fuel resources thanks to a higher breeding ratio than standard LWR. Their uses together with the current fleet of LWR constitute a fuel cycle thoroughly studied in Japan and the US today. However, one of the issues related to HCLWR is their void reactivity coefficient (VRC), which can be positive. Accurate predictions of void reactivity coefficient in HCLWR conditions and their comparisons with representative experiments are therefore required. In this paper an inter comparison of modern codes and cross-section libraries is performed for a former Benchmark on Void Reactivity Effect in PWRs conducted by the OECD/NEA. It shows an overview of the k-inf values and their associated VRC obtained for infinite lattice calculations with UO{sub 2} and highly enriched MOX fuel cells. The codes MCNPX2.5, TRIPOLI4.4 and CASMO-5 in conjunction with the libraries ENDF/B-VI.8, -VII.0, JEF-2.2 and JEFF-3.1 are used. A non-negligible spread of results for voided conditions is found for the high content MOX fuel. The spread of eigenvalues for the moderated and voided UO{sub 2} fuel are about 200 pcm and 700 pcm, respectively. The standard deviation for the VRCs for the UO{sub 2} fuel is about 0.7% while the one for the MOX fuel is about 13%. This work shows that an appropriate treatment of the unresolved resonance energy range is an important issue for the accurate determination of the void reactivity effect for HCLWR. A comparison to experimental results is needed to resolve the presented discrepancies. (authors)

  10. Data on flow cell optimization for membrane-based electrokinetic energy conversion

    Directory of Open Access Journals (Sweden)

    David Nicolas Østedgaard-Munck

    2017-12-01

    Full Text Available This article elaborates on the design and optimization of a specialized flow cell for the measurement of direct conversion of pressure into electrical energy (Electrokinetic Energy Conversion, EKEC which has been presented in Østedgaard-Munck et al. (2017 [1]. Two main flow cell parameters have been monitored and optimized: A the hydraulic pressure profile on each side of the membrane introduced by pumps recirculating the electrolyte solution through the flow fields and B the electrical resistance between the current collectors across the combined flow cell. The latter parameter has been measured using four-point Electrochemical Impedance spectroscopy (EIS for different flow rates and concentrations. The total cell resistance consists of contributions from different components: the membrane (Rmem, anode charge transfer (RA, cathode charge transfer (RC, and ion diffusion in the porous electrodes (RD.The intrinsic membrane properties of Nafion 117 has been investigated experimentally in LiI/I2 solutions with concentrations ranging between 0.06 and 0.96 M and used to identify the preferred LiI/I2 solution concentration. This was achieved by measuring the solution uptake, internal solution concentration and ion exchange capacity. The membrane properties were further used to calculate the transport coefficients and electrokinetic Figure of merit in terms of the Uniform potential and Space charge models. Special attention has been put on the streaming potential coefficient which is an intrinsic property. Keywords: Electrokinetic energy conversion, Electrochemical flow cell, Conversion efficiency

  11. Internal conversion of the (13/2+→5/2-) isomeric transition in 199Hg

    International Nuclear Information System (INIS)

    Radha Krishna, K.; Chandrasekhar Rao, M.V.S.; Sree Krishna Murty, G.; Venkateswara Rao, N.; Bhuloka Reddy, S.; Satyanarayana, G.; Sastry, D.L.; Iyer, M.R.; Sahasrabhude, S.G.

    1990-01-01

    The total conversion coefficient of the M4 transition (374 KeV) in the decay of the 13/2 + isomeric state to 5/2 - state in 199 Hg measured using the relative gamma intensity method α T is determined to be 6.34 ± 0.29 in agreement with the theory due to Rosel et al. (author). 1 tab., 3 figs., 11 refs

  12. Temperature coefficients for GaInP/GaAs/GaInNAsSb solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Aho, Arto; Isoaho, Riku; Tukiainen, Antti; Polojärvi, Ville; Aho, Timo; Raappana, Marianna; Guina, Mircea [Optoelectronics Research Centre, Tampere University of Technology, P.O. Box 692, FIN-33101 Tampere (Finland)

    2015-09-28

    We report the temperature coefficients for MBE-grown GaInP/GaAs/GaInNAsSb multijunction solar cells and the corresponding single junction sub-cells. Temperature-dependent current-voltage measurements were carried out using a solar simulator equipped with a 1000 W Xenon lamp and a three-band AM1.5D simulator. The triple-junction cell exhibited an efficiency of 31% at AM1.5G illumination and an efficiency of 37–39% at 70x real sun concentration. The external quantum efficiency was also measured at different temperatures. The temperature coefficients up to 80°C, for the open circuit voltage, the short circuit current density, and the conversion efficiency were determined to be −7.5 mV/°C, 0.040 mA/cm{sup 2}/°C, and −0.09%/°C, respectively.

  13. Calculation of neutron fluence to dose equivalent conversion coefficients using GEANT4; Calculo de coeficientes de fluencia de neutrons para equivalente de dose individual utilizando o GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Rosane M.; Santos, Denison de S.; Queiroz Filho, Pedro P. de; Mauricio, CLaudia L.P.; Silva, Livia K. da; Pessanha, Paula R., E-mail: rosanemribeiro@oi.com.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    Fluence to dose equivalent conversion coefficients provide the basis for the calculation of area and personal monitors. Recently, the ICRP has started a revision of these coefficients, including new Monte Carlo codes for benchmarking. So far, little information is available about neutron transport below 10 MeV in tissue-equivalent (TE) material performed with Monte Carlo GEANT4 code. The objective of this work is to calculate neutron fluence to personal dose equivalent conversion coefficients, H{sub p} (10)/Φ, with GEANT4 code. The incidence of monoenergetic neutrons was simulated as an expanded and aligned field, with energies ranging between thermal neutrons to 10 MeV on the ICRU slab of dimension 30 x 30 x 15 cm{sup 3}, composed of 76.2% of oxygen, 10.1% of hydrogen, 11.1% of carbon and 2.6% of nitrogen. For all incident energy, a cylindrical sensitive volume is placed at a depth of 10 mm, in the largest surface of the slab (30 x 30 cm{sup 2}). Physic process are included for neutrons, photons and charged particles, and calculations are made for neutrons and secondary particles which reach the sensitive volume. Results obtained are thus compared with values published in ICRP 74. Neutron fluence in the sensitive volume was calculated for benchmarking. The Monte Carlo GEANT4 code was found to be appropriate to calculate neutron doses at energies below 10 MeV correctly. (author)

  14. M1-E2 mixing ratios and B(E2) values for transitions in 131Xe

    International Nuclear Information System (INIS)

    Vijay Sai, K.; Deepa, S.; Ashish, T.; Venkataramaniah, K.; Madhusudan, K.

    2012-01-01

    The accuracies of M1-E2 mixing ratios calculated from the experimental conversion coefficients α i depend upon the accuracy with which the conversion coefficients are determined and also on the accuracy of the theoretical values. Recently a new calculation of ICCs by Band et al, BRICC has been published. The calculations are based on the relativistic DF method in which the exchange interactions between bound electrons and free electrons receding to infinity during the conversion process are treated exactly. Gerl et al showed that BRICC values are more closer to experimental values when compared to earlier theoretical values of Hager and Seltzer and Rosel. The availability of the BRICC values is expected to increase the accuracy with which the estimated quadrupole contents can be obtained

  15. A review of measured values of the milk transfer coefficient (fsub(m)) for iodine

    International Nuclear Information System (INIS)

    Hoffman, F.O.

    1978-01-01

    Most published assessments of the environmental transport of iodine have used a value of 1 X 10 -2 days per litre (d/1) for the transfer coefficient (fsub(m)) which relates the concentration per litre of milk to the daily amount of the element ingested by a cow. However, the USNRC has recommended (USNRC 77) a value of 0.6 X 10 -2 d/1 for the transfer of iodine to cow's milk and 6 X 10 -2 d/1 for goat's milk. A literature survey of published values of fsub(m) leads to a recommendation which deviates from the values chosen by the USNRC. An fsub(m) of 0.5 d/1 for goat's milk and an fsub(m) of 1 X 10 -2 for cow's milk appear to be more appropriate. (author)

  16. Radioactive decay of sup(91m)Nb

    International Nuclear Information System (INIS)

    Lakshminarayana, V.; Venkataratnam, S.; Rao, B.V.T.; Narasimham, K.L.

    1987-01-01

    The radioactive decay of sup(91m)Nb, produced by the reaction 89 Y(α, 2n), is studied using Ge(Li), HPGe and Si(Li) detectors. The K-conversion coefficient, αsub(K), of the 104.5 keV transition is determined accurately, for the first time, from the Nb Ksub(α) x-ray and 104.5 keV gamma-ray intensities. The experimental value of αsub(K) thus determined is 115(5), in agreement with the value expected for an M4 transition. (author)

  17. Conversion of the 42 keV transition in the decay of 191Os

    International Nuclear Information System (INIS)

    Bhuloka Reddy, S.; Narasimham, K.L.; Thirumala Rao, B.V.; Lakshminarayana, V.

    1986-01-01

    The total as well as the L-conversion coefficient of the 42 KeV transition in the decay of 191 Os are determined from intensity balance considerations and XPG technique, respectively, using a 3 mm Si(Li) detector system. The resultant values are αsub(T) = 13709 (1900), αsub(L) = 11700 (2100). The present total conversion coefficients shows good agreement within the uncertainty limits, with the value αsub(T) = 13.500→ 5200 +21100 reported by Lange, whereas the L-conversion coefficient is reported for the first time. Our present values are also compared with the theoretical values interpolated from the tables of Hager and Seltzer and of Rosel et al

  18. Audio watermarking robust against D/A and A/D conversions

    Directory of Open Access Journals (Sweden)

    Xiang Shijun

    2011-01-01

    Full Text Available Abstract Digital audio watermarking robust against digital-to-analog (D/A and analog-to-digital (A/D conversions is an important issue. In a number of watermark application scenarios, D/A and A/D conversions are involved. In this article, we first investigate the degradation due to DA/AD conversions via sound cards, which can be decomposed into volume change, additional noise, and time-scale modification (TSM. Then, we propose a solution for DA/AD conversions by considering the effect of the volume change, additional noise and TSM. For the volume change, we introduce relation-based watermarking method by modifying groups of the energy relation of three adjacent DWT coefficient sections. For the additional noise, we pick up the lowest-frequency coefficients for watermarking. For the TSM, the synchronization technique (with synchronization codes and an interpolation processing operation is exploited. Simulation tests show the proposed audio watermarking algorithm provides a satisfactory performance to DA/AD conversions and those common audio processing manipulations.

  19. Evaluation of dose conversion coefficients for external exposure using Taiwanese reference man and woman

    International Nuclear Information System (INIS)

    Chang, S.J.; Hung, S.Y.; Liu, Y.L.; Jiang, S.H.; Wu, J.

    2015-01-01

    Reference man has been widely used for external and internal dose evaluation of radiation protection. The parameters of the mathematical model of organs suggested by the International Commission of Radiological Protection (ICRP) are adopted from the average data of Caucasians. However, the organ masses of Asians are significantly different from the data of Caucasians, leading to potentially dosimetric errors. In this study, a total of 40 volunteers whose heights and weights corresponded to the statistical average of Taiwanese adults were recruited. Magnetic resonance imaging was performed, and T2-weighted images were acquired. The Taiwanese reference man and woman were constructed according to the measured organ masses. The dose conversion coefficients (DCFs) for anterior-posterior (AP), posterior-anterior (PA), right lateral (RLAT) and left lateral (LLAT) irradiation geometries were simulated. For the Taiwanese reference man, the average differences of the DCFs compared with the results of ICRP-74 were 7.6, 5.1 and 11.1 % for 0.1, 1 and 10 MeV photons irradiated in the AP direction. The maximum difference reached 51.7 % for the testes irradiated by 10 MeV photons. The size of the trunk, the volume and the geometric position of organs can cause a significant impact on the DCFs for external exposure of radiation. The constructed Taiwanese reference man and woman can be used in radiation protection to increase the accuracy of dose evaluation for the Taiwanese population. (authors)

  20. Effects of conversion ratio change on the core performances in medium to large TRU burning reactors

    International Nuclear Information System (INIS)

    Song, Hoon; Kim, Sang-Ji; Yoo, Jae-Woon; Kim, Yeong-Il

    2009-01-01

    Conceptual fast reactor core designs with sodium coolant are developed at 1,500, 3,000 and 4,500 MWt which are configured to transmute recycled transuranics (TRU) elements with external feeds consisting of LWR spent fuel. Even at each pre-determined power level, the performance parameters, reactivity coefficients and their implications on the safety analysis can be different when the target TRU conversion ratio changes. In order to address this aspect of design, a study on TRU conversion ratio change was performed. The results indicate that it is feasible to design a TRU burner core to accommodate a wide range of conversion ratios by employing different fuel cladding thicknesses. The TRU consumption rate is found to be proportional to the core power without any significant deterioration in the core performance at higher power levels. A low conversion ratio core has an increased TRU consumption rate and much faster burnup reactivity loss, which calls for appropriate means for reactivity compensation. As for the reactivity coefficients related with the conversion ratio change, the core with a low conversion ratio has a less negative Doppler coefficient, a more negative axial expansion coefficient, a more negative control rod worth per rod, a more negative radial expansion coefficient, a less positive sodium density coefficient and a less positive sodium void worth. A slight decrease in the delayed neutron fraction is also noted, reflecting the fertile U-238 fraction reduction. (author)

  1. Study and construction of a {beta}-spectrometer of uniform axial magnetic field fitted with a {beta}-{gamma} coincidence selector. Study of the {beta} spectra of {sup 32}P, {sup 203}Hg, {sup 198}Au. Measurement of the conversion coefficients of {sup 203}Ti and of {sup 198}Hg; Etude et realisation d'un spectrometre-{beta} a champ magnetique axial uniforme, muni d'un selecteur de coincidence {beta}-{gamma}. Etude des spectres {beta} du {sup 32}p, {sup 203}Hg, {sup 198}Au. Mesure des coefficients de conversion du {sup 203}Ti et du {sup 198}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Parsignault, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    In the first part is given the principle of the beta spectrometer with uniform axial field using systematically the idea of caustics. The apparatus is described and its properties compared to those deduced from trajectory calculations. The {beta}-ray and {gamma}-ray detectors and the device for selecting coincidences with a 2 {tau} resolution of 5 nanoseconds are also presented. In the second part, the spectrometer is used for studying reference elements and the most accurate results are confirmed. The {beta} spectrum of {sup 60}Co has a statistical form with an accuracy of 1 per cent; the maximum energy E{sub 0} is 316.5 {+-} 1.5 keV. That of the 7/2 + {yields} 11/2 transition for {sup 137}Cs has a unique form, once forbidden. E{sub 0}= 522 {+-} 3 keV. Conversion coefficients {alpha}{sub k} = 96 {+-} 1 X 10{sup -3} {alpha}L + M + N = 20.9 {+-} 0.5 X 10{sup -3}. The two {beta} spectra of {sup 59}Fe, separated by coincidence with the gamma, have the statistical form E{sub 0} = 462 {+-} 2 keV (55.1 + 0,3 per cent) and E{sub 1} = 275 {+-} 4 keV (44.9 {+-} 0.3 per cent). It is then verified whether the l selection rule is apparent in the shape of the phosphorus 32 beta spectrum. It is found in fact that it is not of statistical shape and its shape coefficient is determined. For a theoretical interpretation it is necessary to have better approximations than those generally used and this interpretation will not be unique. This work has also made it possible to show that the source contains a small proportion of {sup 33}P. The study of the {sup 203}Hg {beta} spectrum followed by the 279 keV gamma spectrum is designed to determine the conversion coefficients. The interior spectrum of gold 198 is not of statistical shape either. The form coefficient is determined together with the conversion coefficients which are in slight disagreement with those calculated by Rose or Sliv. An interpretation of the spectrum is put forward which proposes an imperfect compensation for the

  2. Study and construction of a {beta}-spectrometer of uniform axial magnetic field fitted with a {beta}-{gamma} coincidence selector. Study of the {beta} spectra of {sup 32}P, {sup 203}Hg, {sup 198}Au. Measurement of the conversion coefficients of {sup 203}Ti and of {sup 198}Hg; Etude et realisation d'un spectrometre-{beta} a champ magnetique axial uniforme, muni d'un selecteur de coincidence {beta}-{gamma}. Etude des spectres {beta} du {sup 32}p, {sup 203}Hg, {sup 198}Au. Mesure des coefficients de conversion du {sup 203}Ti et du {sup 198}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Parsignault, D. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    In the first part is given the principle of the beta spectrometer with uniform axial field using systematically the idea of caustics. The apparatus is described and its properties compared to those deduced from trajectory calculations. The {beta}-ray and {gamma}-ray detectors and the device for selecting coincidences with a 2 {tau} resolution of 5 nanoseconds are also presented. In the second part, the spectrometer is used for studying reference elements and the most accurate results are confirmed. The {beta} spectrum of {sup 60}Co has a statistical form with an accuracy of 1 per cent; the maximum energy E{sub 0} is 316.5 {+-} 1.5 keV. That of the 7/2 + {yields} 11/2 transition for {sup 137}Cs has a unique form, once forbidden. E{sub 0}= 522 {+-} 3 keV. Conversion coefficients {alpha}{sub k} = 96 {+-} 1 X 10{sup -3} {alpha}L + M + N = 20.9 {+-} 0.5 X 10{sup -3}. The two {beta} spectra of {sup 59}Fe, separated by coincidence with the gamma, have the statistical form E{sub 0} = 462 {+-} 2 keV (55.1 + 0,3 per cent) and E{sub 1} = 275 {+-} 4 keV (44.9 {+-} 0.3 per cent). It is then verified whether the l selection rule is apparent in the shape of the phosphorus 32 beta spectrum. It is found in fact that it is not of statistical shape and its shape coefficient is determined. For a theoretical interpretation it is necessary to have better approximations than those generally used and this interpretation will not be unique. This work has also made it possible to show that the source contains a small proportion of {sup 33}P. The study of the {sup 203}Hg {beta} spectrum followed by the 279 keV gamma spectrum is designed to determine the conversion coefficients. The interior spectrum of gold 198 is not of statistical shape either. The form coefficient is determined together with the conversion coefficients which are in slight disagreement with those calculated by Rose or Sliv. An interpretation of the spectrum is put forward which proposes an imperfect compensation for the

  3. Review of measured values of the milk transfer coefficient f/sub m/ for iodine

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, F O [Oak Ridge National Lab., TN (USA)

    1978-08-01

    Most published assessments of the environmental transport of iodine have used a value of 1 X 10/sup -2/ days per litre (d/1) for the transfer coefficient (fsub(m)) which relates the concentration per litre of milk to the daily amount of the element ingested by a cow. However, the USNRC has recommended (USNRC 77) a value of 0.6 X 10/sup -2/ d/1 for the transfer of iodine to cow's milk and 6 X 10/sup -2/ d/1 for goat's milk. A literature survey of published values of fsub(m) leads to a recommendation which deviates from the values chosen by the USNRC. An fsub(m) of 0.5 d/1 for goat's milk and an fsub(m) of 1 X 10/sup -2/ for cow's milk appear to be more appropriate.

  4. Transport coefficients of InSb in a strong magnetic field

    International Nuclear Information System (INIS)

    Nakamura, Hiroaki; Ikeda, Kazuaki; Yamaguchi, Satarou

    1998-02-01

    Improvement of a superconducting magnet system makes induction of a strong magnetic field easier. This fact gives us a possibility of energy conversion by the Nernst effect. As the first step to study the Nernst element, we measured the conductivity, the Hall coefficient, the thermoelectric power and the Nernst coefficient of the InSb, which is one of candidates of the Nernst elements. From this experiment, it is concluded that the Nernst coefficient is smaller than the theoretical values. On the other hand, the conductivity, the Hall coefficient and the thermoelectric power has the values expected by the theory. (author)

  5. Coeficiente de corrección en engranajes cilíndricos como factor de conversión entre sistemas AGMA e ISO. // Addendum modification coefficient as conversion factor of cylindrical gears in AGMA system to ISO standards.

    Directory of Open Access Journals (Sweden)

    G. González Rey

    2007-09-01

    Full Text Available A partir de la experiencia de los autores, en trabajos asociados con el análisis para la reconversión de engranajes ensistemas AGMA a partir de herramientas con referencia a normas ISO, en el artículo se pretende exponer las principalesdefiniciones y recomendaciones asociadas al coeficiente de corrección relativo al módulo en engranajes cilíndricos de ejesparalelos con dientes de flanco de evolvente que permitan un racional cálculo de la geometría del engranaje y apreciarmediante ejemplos la ventaja del coeficiente de corrección en la solución de problemas prácticos de conversión deengranajes en sistemas AGMA a ISO.Palabras claves: geometría de engranaje cilíndrico, coeficiente de corrección, conversión AGMA a ISO________________________________________________________________________________AbstractDefinitions and recommendations associated to the addendum modification coefficient are presented. Examples, based onauthor’s experiences in the analysis, recovery and conversion of helical and spur gears in AGMA system to ISO standards showthe advantage of application of the addendum modification coefficient in the solution of practical problems and rationalcalculation of gears.Key words: external parallel-axis cylindrical involute gears, gear geometry, , ISO gear standards, rack shift coefficient x

  6. Radioactive decay of sup(91m)Nb

    Energy Technology Data Exchange (ETDEWEB)

    Lakshminarayana, V.; Venkataratnam, S.; Rao, B.V.T.; Narasimham, K.L.; Chintalapudi, S.N.

    1987-08-01

    The radioactive decay of sup(91m)Nb, produced by the reaction /sup 89/Y(..cap alpha.., 2n), is studied using Ge(Li), HPGe and Si(Li) detectors. The K-conversion coefficient, ..cap alpha..sub(K), of the 104.5 keV transition is determined accurately, for the first time, from the Nb Ksub(..cap alpha..) x-ray and 104.5 keV gamma-ray intensities. The experimental value of ..cap alpha..sub(K) thus determined is 115(5), in agreement with the value expected for an M4 transition.

  7. A simple theory of linear mode conversion

    International Nuclear Information System (INIS)

    Cairns, R.A.; Lashmore-Davies, C.N.; Woods, A.M.

    1984-01-01

    A summary is given of the basic theory of linear mode conversion involving the construction of differential equations for the mode amplitudes based on the properties of the dispersion relation in the neighbourhood of the mode conversion point. As an example the transmission coefficient for tunneling from the upper hybrid resonance through the evanescent region to the adjacent cut-off is treated. 7 refs, 3 figs

  8. Treatment of post-transplantation lymphoproliferative disorders after kidney transplant with rituximab and conversion to m-TOR inhibitor.

    Science.gov (United States)

    Nieto-Rios, John Fredy; Gómez de Los Ríos, Sandra Milena; Serna-Higuita, Lina María; Ocampo-Kohn, Catalina; Aristizabal-Alzate, Arbey; Gálvez-Cárdenas, Kenny Mauricio; Zuluaga-Valencia, Gustavo Adolfo

    2016-12-30

    Post-transplantation lymphoproliferative disorders are serious complications of organ transplantation which treatment is not yet standardized. To describe the clinical response, overall and graft survival of patients in our center with this complication after kidney transplantation, which received rituximab as part of their treatment as well as conversion to m-TOR. Retrospective study, which included patients, diagnosed with post-transplant lymphoproliferative disorders after kidney transplantation from January 2011 to July 2014. Eight cases were found with a wide spectrum of clinical presentations. Most had monomorphic histology, 85% were associated with Epstein-Barr virus, 25% of patients had tumor involvement of the renal graft, and 12.5% ​​had primary central nervous system lymphoma. All patients were managed with reduction of immunosuppression, conversion to m-TOR (except one who lost the graft at diagnosis) and rituximab-based therapy. The overall response rate was 87.5% (62.5% complete response, 25% partial response). Survival was 87.5% with a median follow-up of 34 months. An additional patient lost the graft, with chronic nephropathy already known. All the remaining patients had stable renal function. There are no standardized treatment regimens for lymphoproliferative disorders after kidney transplantation, but these patients can be managed successfully with reduction of immunosuppression, conversion to m-TOR and rituximab-based schemes.

  9. Determination of the external mass transfer coefficient and influence of mixing intensity in moving bed biofilm reactors for wastewater treatment.

    Science.gov (United States)

    Nogueira, Bruno L; Pérez, Julio; van Loosdrecht, Mark C M; Secchi, Argimiro R; Dezotti, Márcia; Biscaia, Evaristo C

    2015-09-01

    In moving bed biofilm reactors (MBBR), the removal of pollutants from wastewater is due to the substrate consumption by bacteria attached on suspended carriers. As a biofilm process, the substrates are transported from the bulk phase to the biofilm passing through a mass transfer resistance layer. This study proposes a methodology to determine the external mass transfer coefficient and identify the influence of the mixing intensity on the conversion process in-situ in MBBR systems. The method allows the determination of the external mass transfer coefficient in the reactor, which is a major advantage when compared to the previous methods that require mimicking hydrodynamics of the reactor in a flow chamber or in a separate vessel. The proposed methodology was evaluated in an aerobic lab-scale system operating with COD removal and nitrification. The impact of the mixing intensity on the conversion rates for ammonium and COD was tested individually. When comparing the effect of mixing intensity on the removal rates of COD and ammonium, a higher apparent external mass transfer resistance was found for ammonium. For the used aeration intensities, the external mass transfer coefficient for ammonium oxidation was ranging from 0.68 to 13.50 m d(-1) and for COD removal 2.9 to 22.4 m d(-1). The lower coefficient range for ammonium oxidation is likely related to the location of nitrifiers deeper in the biofilm. The measurement of external mass transfer rates in MBBR will help in better design and evaluation of MBBR system-based technologies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Monte Carlo calculations of calibrations of calibration coefficients of ATL monitors installed at NPP Temelin

    International Nuclear Information System (INIS)

    Solc, J.; Suran, J.; Novotna, M.; Pavlis, J.

    2008-01-01

    The contribution describes a technique of determination of calibration coefficients of a radioactivity monitor using Monte Carlo calculations. The monitor is installed at the NPP Temelin adjacent to lines with a radioactive medium. The output quantity is the activity concentration (in Bq/m3) that is converted from the number of counts per minute measured by the monitor. The value of this conversion constant, i.e. calibration coefficient, was calculated for gamma photons emitted by Co-60 and compared to the data stated by the manufacturer and supplier of these monitors, General Atomic Electronic Systems, Inc., USA. Results of the comparison show very good agreement between calculations and manufacturer data; the differences are lower than the quadratic sum of uncertainties. (authors)

  11. Highly coherent red-shifted dispersive wave generation around 1.3 μm for efficient wavelength conversion

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xia; Bi, Wanjun [Key Laboratory of Materials for High Power Laser, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100039 (China); Chen, Wei; Xue, Tianfeng; Hu, Lili; Liao, Meisong, E-mail: liaomeisong@siom.ac.cn [Key Laboratory of Materials for High Power Laser, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Gao, Weiqing [School of Electronic Science and Applied Physics, Hefei University of Technology, Hefei 230009 (China)

    2015-03-14

    This research investigates the mechanism of the optical dispersive wave (DW) and proposes a scheme that can realize an efficient wavelength conversion. In an elaborately designed photonic crystal fiber, a readily available ytterbium laser operating at ∼1 μm can be transferred to the valuable 1.3 μm wavelength range. A low-order soliton is produced to concentrate the energy of the DW into the target wavelength range and improve the degree of coherence. The input chirp is demonstrated to be a factor that enhances the wavelength conversion efficiency. With a positive initial chirp, 76.6% of the pump energy in the fiber can be transferred into a spectral range between 1.24 and 1.4 μm. With the use of a grating compressor, it is possible to compress the generated coherent DW of several picoseconds into less than 90 fs.

  12. Foetal dose conversion coefficients for ICRP-compliant pregnant models from idealised proton exposures

    International Nuclear Information System (INIS)

    Taranenko, V.; Xu, X. G.

    2009-01-01

    Protection of pregnant women and their foetus against external proton irradiations poses a unique challenge. Assessment of foetal dose due to external protons in galactic cosmic rays and as secondaries generated in aircraft walls is especially important during high-altitude flights. This paper reports a set of fluence to absorbed dose conversion coefficients for the foetus and its brain for external monoenergetic proton beams of six standard configurations (the antero-posterior, the postero-anterior, the right lateral, the left lateral, the rotational and the isotropic). The pregnant female anatomical definitions at each of the three gestational periods (3, 6 and 9 months) are based on newly developed RPI-P series of models whose organ masses were matched within 1% with the International Commission on Radiological Protection reference values. Proton interactions and the transport of secondary particles were carefully simulated using the Monte Carlo N-Particle extended code (MCNPX) and the phantoms consisting of several million voxels at 3 mm resolution. When choosing the physics models in the MCNPX, it was found that the advanced Cascade-Exciton intranuclear cascade model showed a maximum of 9% foetal dose increase compared with the default model combination at intermediate energies below 5 GeV. Foetal dose results from this study are tabulated and compared with previously published data that were based on simplified anatomy. The comparison showed a strong dependence upon the source geometry, energy and gestation period: The dose differences are typically less than 20% for all sources except ISO where systematically 40-80% of higher doses were observed. Below 200 MeV, a larger discrepancy in dose was found due to the Bragg peak shift caused by different anatomy. The tabulated foetal doses represent the latest and most detailed study to date offering a useful set of data to improve radiation protection dosimetry against external protons. (authors)

  13. Dependence of Seebeck coefficient on a load resistance and energy conversion efficiency in a thermoelectric composite

    International Nuclear Information System (INIS)

    Yamashita, Osamu; Odahara, Hirotaka; Ochi, Takahiro; Satou, Kouji

    2007-01-01

    The thermo-emf ΔV and current ΔI generated by imposing the alternating temperature gradients (ATG) at a period of T and the steady temperature gradient (STG) on a thermoelectric (TE) composite were measured as a function of t, where t is the lapsed time and T was varied from 60 to or ∞ s. The STG and ATG were produced by imposing steadily and alternatively a source voltage V in the range from 1.0 to 4.0 V on two Peltier modules sandwiching a composite. ΔT, ΔV, ΔI and V P oscillate at a period T and their waveforms vary significantly with a change of T, where ΔV and V P are the voltage drops in a load resistance R L and in resistance R P of two modules. The resultant Seebeck coefficient |α| = |ΔV|/ΔT of a composite under the STG was found to be expressed as |α| = |α 0 |(1 - R comp /R T ), where R T is the total resistance of a circuit for measuring the output signals and R comp is the resistance of a composite. The effective generating power ΔW eff has a local maximum at T = 960 s for the p-type composite and at T = 480 s for the n-type one. The maximum energy conversion efficiency η of the p- and n-type composites under the ATG produced by imposing a voltage of 4.0 V at an optimum period were 0.22 and 0.23% at ΔT eff = 50 K, respectively, which are 42 and 43% higher than those at ΔT = 42 K under the STG. These maximum η for a TE composite sandwiched between two Peltier modules, were found to be expressed theoretically in terms of R P , R T , R L , α P and α, where α P and α are the resultant Seebeck coefficients of Peltier modules and a TE composite

  14. Improvement of dose evaluation system for employees at severe accident in a nuclear power plant. Introduction of the dose rate conversion coefficient and addition of the access route edit function

    International Nuclear Information System (INIS)

    Sasaki, Yasuhiro; Minami, Noritoshi; Yoshida, Yoshitaka

    2006-01-01

    Institute of Nuclear Safety System, Inc. had developed the dose evaluation system to evaluate the radiation dose of employees at severe accident in a nuclear power plant. This system has features, which are (1) the dose rate of any evaluation point can be evaluated, (2) the dose rate at any time can be evaluated in consideration of the change in the radioactive source, (3) the dose rate map in the plant can be displayed (4) the dose along the access route when moving can be evaluated, and it is possible to use it for examination of the accident management guideline on the dose side etc.. To upgrade the dose evaluation function of this system, the improvements had been done which were introduction of the dose rate conversion coefficient and addition of the access route edit function. By introducing the dose rate conversion coefficient, the calculation time of the dose rate map in the plant was shortened at about 20 seconds, and a new function to evaluate time-dependent dose rate of any evaluation point was added. By adding the access route edit function, it became possible to re-calculate the dose easily at the route change. (author)

  15. Hydrogen photoproduction by photoelectrochemical conversion

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    The water-splitting reaction by photoelectrochemical processes has gained much more attention than any of many reactions proposed for solar generation of energy-rich molecules (fuels). The conversion efficiency of the photosystem is the key factor. The higher the efficiency, the more economically feasible will be the conversion scheme. The conversion efficiency is a function of the semiconductor properties, light intensity, spectral quality, properties of the electrolyte, counterelectrode, cell configuration, etc. The semiconductor parameters include band gap, absorption coefficient and diffusion length. The area and material used for a counterelectrode are important when considering polarization losses in a two-electrode system. Besides, the stability problem is also a very important one to meet the requirement for practical applications. This paper reviews some important issues on photoelectrochemical generation of hydrogen by water splitting. It includes energy conversion efficiency, market assessment and cost goal, state of the technology, and future directions for research

  16. High Molar Extinction Coefficient Ru(II-Mixed Ligand Polypyridyl Complexes for Dye Sensitized Solar Cell Application

    Directory of Open Access Journals (Sweden)

    Malapaka Chandrasekharam

    2011-01-01

    Full Text Available Two new ruthenium(II mixed ligand terpyridine complexes, “Ru(Htcterpy(NCS(L1 (N(C4H94, mLBD1” and Ru(Htcterpy(NCS(L2(N(C4H94, mLBD2 were synthesized and fully characterized by UV-Vis, emission, cyclic voltammogram, and other spectroscopic means, and the structures of the compounds are confirmed by 1H-NMR, ESI-MASS, and FT-IR spectroscopes. The influence of the substitution of L1 and L2 on solar-to-electrical energy conversion efficiency (η of dye-sensitized solar cells (DSSCs was evaluated relative to reference black dye. The dyes showed molar extinction coefficients of 17600 M−1 cm−1 for mLBD1 and 21300 M−1 cm−1 for mLBD2 both at λ maximum of 512 nm, while black dye has shown 8660 M−1 cm−1 at λ maximum of 615 nm. The monochromatic incident photon-to-collected electron conversion efficiencies of 60.71% and 75.89% were obtained for mLBD1 and mLBD2 dyes, respectively. The energy conversion efficiencies of mLBD1 and mLBD2 dyes are 3.15% (SC=11.86 mA/cm2, OC=613 mV, ff=0.4337 and 3.36% (SC=12.71 mA/cm2, OC=655 mV, ff=0.4042, respectively, measured at the AM1.5G conditions, the reference black dye-sensitized solar cell, fabricated and evaluated under identical conditions exhibited η-value of 2.69% (SC=10.95 mA/cm2, OC=655 mV, ff=0.3750.

  17. The conversion factor of α radiation efficiency

    International Nuclear Information System (INIS)

    Wang Weida; Zhou Zhixin; Xia Junding

    1997-01-01

    It is important in fine-grain TL dating that the full α dose must be converted into the equivalent β dose. Although the conversion coefficient K for internal radiation efficiency can not be measured directly for each sample, it is possible to measure the external radiation efficiency K 3.7 . For this purpose a special study for the conversion factor of K to K 3.7 has been made using ultrathin TLD. The results show that the conversion factor of the TLD for archaeological samples is 0.847, which is in agreement with the calculated value 0.85

  18. The modified gait abnormality rating scale in patients with a conversion disorder: a reliability and responsiveness study.

    Science.gov (United States)

    Vandenberg, Justin M; George, Deanna R; O'Leary, Andrea J; Olson, Lindsay C; Strassburg, Kaitlyn R; Hollman, John H

    2015-01-01

    Individuals with conversion disorder have neurologic symptoms that are not identified by an underlying organic cause. Often the symptoms manifest as gait disturbances. The modified gait abnormality rating scale (GARS-M) may be useful for quantifying gait abnormalities in these individuals. The purpose of this study was to examine the reliability, responsiveness and concurrent validity of GARS-M scores in individuals with conversion disorder. Data from 27 individuals who completed a rehabilitation program were included in this study. Pre- and post-intervention videos were obtained and walking speed was measured. Five examiners independently evaluated gait performance according to the GARS-M criteria. Inter- and intrarater reliability of GARS-M scores were estimated with intraclass correlation coefficients (ICCs). Responsiveness was estimated with the minimum detectable change (MDC). Pre- to post-treatment changes in GARS-M scores were analyzed with a dependent t-test. The correlation between GARS-M scores and walking speed was analyzed to assess concurrent validity. GARS-M scores were quantified with good-to-excellent inter- (ICC = 0.878) and intrarater reliability (ICC = 0.989). The MDC was 2 points. Mean GARS-M scores decreased from 7 ± 5 at baseline to 1 ± 2 at discharge (t26 = 7.411, p conversion disorder. GARS-M scores provide objective measures upon which treatment effects can be assessed. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Classification of the coefficients of variation of parameters evaluated in Japanese quail experiments

    Directory of Open Access Journals (Sweden)

    DHV Leal

    2014-06-01

    Full Text Available The objective of this study was to design a classification range of the coefficients of variation (CV of traits used in experiments with eggtype Japanese quails (Coturnix coturnix japonica. The journal Revista Brasileira de Zootecnia was systematically reviewed, using the key word 'quail' during the period of January, 2000 to 2010. The CV of feed intake (g/bird/d, egg production (%/bird/d, egg weight (g, egg mass (g/bird/d, feed conversion ratio per dozen eggs (g/dozen, feed conversion ratio per egg mass (g/g, and egg specific gravity (g/mL were collected. For each parameter, CV were classified using the following median (MD and pseudo-sigma (PS ratio as follows: low (CV MD + 2PS. According to the results, it was concluded that each parameter has a specific classification range that should be taken into account when evaluating experimental precision.

  20. Measurement of conversion coefficients between air Kerma and personal dose equivalent and backscatter factors for diagnostic X-ray beams; Determinacao experimental dos coeficientes de conversao de Kerma no ar para o equivalente de dose pessoal, Hp(d), e fatores de retroespalhamento em feixes de raios-x diagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Rosado, Paulo Henrique Goncalves

    2008-07-01

    Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm{sup 3} Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm x 300 mm x 150 mm polymethylmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with {sup 133} Ba, {sup 241} Am and {sup 57} Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of

  1. High Selectively Catalytic Conversion of Lignin-Based Phenols into para-/m-Xylene over Pt/HZSM-5

    Directory of Open Access Journals (Sweden)

    Guozhu Liu

    2016-01-01

    Full Text Available High selectively catalytic conversion of lignin-based phenols (m-cresol, p-cresol, and guaiacol into para-/m-xylene was performed over Pt/HZSM-5 through hydrodeoxygenation and in situ methylation with methanol. It is found that the p-/m-xylene selectivity is uniformly higher than 21%, and even increase up to 33.5% for m-cresol (with phenols/methanol molar ratio of 1/8. The improved p-/m-xylene selectivity in presence of methanol is attributed to the combined reaction pathways: methylation of m-cresol into xylenols followed by HDO into p-/m-xylene, and HDO of m-cresol into toluene followed by methylation into p-/m-xylene. Comparison of the product distribution over a series of catalysts indicates that both metals and supporters have distinct effect on the p-/m-xylene selectivity.

  2. The measurement of internal conversion electrons of selected nuclei: A physics undergraduate laboratory experience

    International Nuclear Information System (INIS)

    Nagy, P.; Duggan, J.L.; Desmarais, D.

    1992-01-01

    Thin sources are now commercially available for a wide variety of isotopes that have measurable internal conversion coefficients. The authors have used standard surface barrier detectors, NIM electronics, and a personal computer analyzer to measure conversion electrons from a few of these sources. Conversion electrons energy and intensity were measured for 113 Sn, 133 Ba, 137 Cs, and 207 Bi. From the measured spectra the innershell binding energies of the K ampersand L Shell electrons from the daughter nuclei were determined and compared to theory. The relative conversion coefficients a k /a L and the K/L ration were also measured. The spin and parity change of the transitions will also be assigned based on the selection rules of the transitions

  3. On-chip all-optical wavelength conversion of multicarrier, multilevel modulation (OFDM m-QAM) signals using a silicon waveguide.

    Science.gov (United States)

    Li, Chao; Gui, Chengcheng; Xiao, Xi; Yang, Qi; Yu, Shaohua; Wang, Jian

    2014-08-01

    We report on-chip all-optical wavelength conversion of multicarrier multilevel modulation signals in a silicon waveguide. Using orthogonal frequency-division multiplexing (OFDM) combined with advanced multilevel quadrature amplitude modulation (QAM) signals (i.e., OFDM m-QAM), we experimentally demonstrate all-optical wavelength conversions of 3.2 Gbaud/s OFDM 16/32/64/128-QAM signals based on the degenerate four-wave mixing (FWM) nonlinear effect in a silicon waveguide. The measured optical signal-to-noise ratio (OSNR) penalties of wavelength conversion are ∼3  dB for OFDM 16-QAM and ∼4  dB for OFDM 32-QAM at 7% forward error correction (FEC) threshold and ∼3.5  dB for OFDM 64-QAM and ∼4.5  dB for OFDM 128-QAM at 20% FEC threshold. The observed clear constellations of converted idlers imply favorable performance obtained for silicon-waveguide-based OFDM 16/32/64/128-QAM wavelength conversions.

  4. Magnitude conversion to unified moment magnitude using orthogonal regression relation

    Science.gov (United States)

    Das, Ranjit; Wason, H. R.; Sharma, M. L.

    2012-05-01

    Homogenization of earthquake catalog being a pre-requisite for seismic hazard assessment requires region based magnitude conversion relationships. Linear Standard Regression (SR) relations fail when both the magnitudes have measurement errors. To accomplish homogenization, techniques like Orthogonal Standard Regression (OSR) are thus used. In this paper a technique is proposed for using such OSR for preparation of homogenized earthquake catalog in moment magnitude Mw. For derivation of orthogonal regression relation between mb and Mw, a data set consisting of 171 events with observed body wave magnitudes (mb,obs) and moment magnitude (Mw,obs) values has been taken from ISC and GCMT databases for Northeast India and adjoining region for the period 1978-2006. Firstly, an OSR relation given below has been developed using mb,obs and Mw,obs values corresponding to 150 events from this data set. M=1.3(±0.004)m-1.4(±0.130), where mb,proxy are body wave magnitude values of the points on the OSR line given by the orthogonality criterion, for observed (mb,obs, Mw,obs) points. A linear relation is then developed between these 150 mb,obs values and corresponding mb,proxy values given by the OSR line using orthogonality criterion. The relation obtained is m=0.878(±0.03)m+0.653(±0.15). The accuracy of the above procedure has been checked with the rest of the data i.e., 21 events values. The improvement in the correlation coefficient value between mb,obs and Mw estimated using the proposed procedure compared to the correlation coefficient value between mb,obs and Mw,obs shows the advantage of OSR relationship for homogenization. The OSR procedure developed in this study can be used to homogenize any catalog containing various magnitudes (e.g., ML, mb, MS) with measurement errors, by their conversion to unified moment magnitude Mw. The proposed procedure also remains valid in case the magnitudes have measurement errors of different orders, i.e. the error variance ratio is

  5. Effects of Lowering Dialysate Calcium Concentration on Mineral and Bone Disorders in Chronic Hemodialysis Patients: Conversion from 3.0 mEq/L to 2.75 mEq/L.

    Science.gov (United States)

    Yamada, Shunsuke; Ueki, Kenji; Tokumoto, Masanori; Suehiro, Takaichi; Kimura, Hiroshi; Taniguchi, Masatomo; Fujimi, Satoru; Kitazono, Takanari; Tsuruya, Kazuhiko

    2016-02-01

    Selection of a lower dialysate calcium concentration (DCa) can reduce calcium burden and prevent vascular calcification in hemodialysis patients. However, decreased DCa can worsen mineral and bone disorders. This 1-year retrospective observational study evaluated 121 hemodialysis patients at Fukuoka Renal Clinic who underwent conversion of DCa from 3.0 mEq/L to 2.75 mEq/L. The primary outcomes were changes in serum levels of calcium, phosphate, and parathyroid hormone (PTH). The effects of baseline serum calcium and PTH levels on changes in biochemical parameters were also determined. One year after DCa conversion, mean serum calcium level decreased, while serum phosphate, alkaline phosphatase, and PTH concentrations increased. The rate of achievement of target PTH was higher in patients with lower serum PTH level at baseline, while patients with higher baseline serum PTH level tended to exceed the upper limit of the PTH target range. Patients with higher baseline serum calcium concentration showed a greater decrease in serum calcium level and a greater increase in serum PTH level at 1 year. Patients with a lower baseline serum PTH level can benefit from optimal PTH control following conversion of DCa from 3.0 mEq/L to 2.75 mEq/L. However, secondary hyperparathyroidism may be exacerbated in some patients with higher baseline serum calcium (Ca) and PTH levels. These results indicate that an individualized approach can maximize the benefits of Ca unloading after conversion to lower DCa. © 2015 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  6. Fluence-to-dose conversion coefficients based on the posture modification of Adult Male (AM) and Adult Female (AF) reference phantoms of ICRP 110

    International Nuclear Information System (INIS)

    Galeano, D.C.; Santos, W.S.; Alves, M.C.; Souza, D.N.; Carvalho, A.B.

    2016-01-01

    The aim of this work was to modify the standing posture of the anthropomorphic reference phantoms of ICRP publication 110, AM (Adult Male) and AF (Adult Female), to the sitting posture. The change of posture was performed using the Visual Monte Carlo software (VMC) to rotate the thigh region of the phantoms and position it between the region of the leg and trunk. Scion Image software was used to reconstruct and smooth the knee and hip contours of the phantoms in a sitting posture. For 3D visualization of phantoms, the VolView software was used. In the change of postures, the organ and tissue masses were preserved. The MCNPX was used to calculate the equivalent and effective dose conversion coefficients (CCs) per fluence for photons for six irradiation geometries suggested by ICRP publication 110 (AP, PA, RLAT, LLAT, ROT and ISO) and energy range 0.010–10 MeV. The results were compared between the standing and sitting postures, for both sexes, in order to evaluate the differences of scattering and absorption of radiation for different postures. Significant differences in the CCs for equivalent dose were observed in the gonads, colon, prostate, urinary bladder and uterus, which are present in the pelvic region, and in organs distributed throughout the body, such as the lymphatic nodes, muscle, skeleton and skin, for the phantoms of both sexes. CCs for effective dose showed significant differences of up to 16% in the AP irradiation geometry, 27% in the PA irradiation geometry and 13% in the ROT irradiation geometry. These results demonstrate the importance of using phantoms in different postures in order to obtain more precise conversion coefficients for a given exposure scenario. - Highlights: • The reference phantoms AM and AF had modified its posture. • The AM and AF phantoms were irradiated in standing and sitting postures. • The irradiation geometry used were the AP, PA, LLAT, RLAT, ROT and ISO. • The CCs for standing and sitting postures were compared

  7. On the ideal and real energy conversion in a straight bladed vertical axis wind turbine. The actuator cylinder flow model compared with experiment

    Energy Technology Data Exchange (ETDEWEB)

    Aaagard Madsen, H.

    1983-01-01

    The ideal and the real energy conversion in a straight bladed vertical axis wind turbine (VAWT) with variable pitch has been studied on basis of the actuator cylinder flow model and experimental data from free wind tests on a 9 m/sup 2/ turbine. Particularly, the theoretical upper power limit of VAWT's has been focused upon in the light of the already existing theories for horizontal axis wind turbines (HAWT's). A remarkable result, differing from prior theories, has turned out through the computations with the actuator cylinder flow model and that is: The maximum ideal power coefficient for VAWT's seams neither to be bounded by the Lanchester-Betz power coefficient limit of 16/27 (actuator disc concept), nor by Glauert's ideal power coefficient curve (taking into account the tip speed ratio), both limits derived with particular reference to HAWT's. Concerning the agreement between analysis and the measurements of the power coefficient, the rotor drag coefficient and the flow velocity vector adjacent to the swept area, it was in general found to be good. However, there seems still to be need for future research on the influence of turbulence in the free wind and dynamic stall on the real energy conversion in VAWT's.

  8. Conversion of electromagnetic waves at the ionisation front

    International Nuclear Information System (INIS)

    Chegotov, M V

    2001-01-01

    It is shown that a weak electromagnetic pulse interacting with a copropagating ionisation front is converted in the general case into three electromagnetic pulses with higher and lower frequencies, which propagate in different directions. The coefficients of conversion to these pulses (for intensities) were found as functions of the frequency. The electromagnetic energy is shown to decrease during this conversion because of the losses for the residual electron energy. (interaction of laser radiation with matter. laser plasma)

  9. Roughness coefficient and its uncertainty in gravel-bed river

    Directory of Open Access Journals (Sweden)

    Ji-Sung Kim

    2010-06-01

    Full Text Available Manning's roughness coefficient was estimated for a gravel-bed river reach using field measurements of water level and discharge, and the applicability of various methods used for estimation of the roughness coefficient was evaluated. Results show that the roughness coefficient tends to decrease with increasing discharge and water depth, and over a certain range it appears to remain constant. Comparison of roughness coefficients calculated by field measurement data with those estimated by other methods shows that, although the field-measured values provide approximate roughness coefficients for relatively large discharge, there seems to be rather high uncertainty due to the difference in resultant values. For this reason, uncertainty related to the roughness coefficient was analyzed in terms of change in computed variables. On average, a 20% increase of the roughness coefficient causes a 7% increase in the water depth and an 8% decrease in velocity, but there may be about a 15% increase in the water depth and an equivalent decrease in velocity for certain cross-sections in the study reach. Finally, the validity of estimated roughness coefficient based on field measurements was examined. A 10% error in discharge measurement may lead to more than 10% uncertainty in roughness coefficient estimation, but corresponding uncertainty in computed water depth and velocity is reduced to approximately 5%. Conversely, the necessity for roughness coefficient estimation by field measurement is confirmed.

  10. A study of core electron binding energies in technetium-99m complexes by internal conversion electron spectroscopy

    International Nuclear Information System (INIS)

    Burke, J.F.; Archer, C.M.; Wei Chiu, K.; Latham, I.A.; Egdell, R.G.

    1991-01-01

    Core electron binding energies in a series of 99m Tc complexes have been studied by internal conversion electron spectroscopy (ICES) in a conventional x-ray photoelectron spectrometer. In both 3d and 3p regions, a chemical shift of about 1 eV is observed per unit increase in oxidation state. The role of ICES in characterizing radiopharmaceutical agents is illustrated with studies of some novel 99m Tc-phosphine complexes that have been developed for myocardial perfusion imaging. (author)

  11. Fluence-to-absorbed-dose conversion coefficients for neutron beams from 0.001 eV to 100 GeV calculated for a set of pregnant female and fetus models

    International Nuclear Information System (INIS)

    Taranenko, Valery; Xu, X George

    2008-01-01

    Protection of fetuses against external neutron exposure is an important task. This paper reports a set of absorbed dose conversion coefficients for fetal and maternal organs for external neutron beams using the RPI-P pregnant female models and the MCNPX code. The newly developed pregnant female models represent an adult female with a fetus including its brain and skeleton at the end of each trimester. The organ masses were adjusted to match the reference values within 1%. For the 3 mm cubic voxel size, the models consist of 10-15 million voxels for 35 organs. External monoenergetic neutron beams of six standard configurations (AP, PA, LLAT, RLAT, ROT and ISO) and source energies 0.001 eV-100 GeV were considered. The results are compared with previous data that are based on simplified anatomical models. The differences in dose depend on source geometry, energy and gestation periods: from 20% up to 140% for the whole fetus, and up to 100% for the fetal brain. Anatomical differences are primarily responsible for the discrepancies in the organ doses. For the first time, the dependence of mother organ doses upon anatomical changes during pregnancy was studied. A maximum of 220% increase in dose was observed for the placenta in the nine months model compared to three months, whereas dose to the pancreas, small and large intestines decreases by 60% for the AP source for the same models. Tabulated dose conversion coefficients for the fetus and 27 maternal organs are provided

  12. Deuterons at energies of 10 MeV to 1 TeV: Conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C

    International Nuclear Information System (INIS)

    Copeland, K.; Parker, D. E.; Friedberg, W.

    2011-01-01

    Conversion coefficients were calculated for fluence-to-absorbed dose, fluence-to-equivalent dose, fluence-to-effective dose and fluence-to-gray equivalent for isotropic exposure of an adult female and an adult male to deuterons ( 2 H + ) in the energy range 10 MeV -1 TeV (0.01-1000 GeV). Coefficients were calculated using the Monte Carlo transport code MCNPX 2.7.C and BodyBuilder TM 1.3 anthropomorphic phantoms. Phantoms were modified to allow calculation of the effective dose to a Reference Person using tissues and tissue weighting factors from 1990 and 2007 recommendations of the International Commission on Radiological Protection (ICRP) and gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. Coefficients for the equivalent and effective dose incorporated a radiation weighting factor of 2. At 15 of 19 energies for which coefficients for the effective dose were calculated, coefficients based on ICRP 1990 and 2007 recommendations differed by < 3 %. The greatest difference, 47 %, occurred at 30 MeV. (authors)

  13. Extraction of Dunham coefficients from Murrell-Sorbie parameters

    International Nuclear Information System (INIS)

    Lim Teikcheng

    2008-01-01

    A set of relationships between parameters of the Dunham and Murrell-Sorbie potential energy function is developed. By employing Taylor series expansion and comparison of terms arranged in increasing order of bond length, a set of Dunham coefficients is obtained as functions of Murrell- Sorbie parameters. The conversion functions reveal the importance of factorials in extracting Dunham coefficients from Murrell-Sorbie parameters. Plots of both functions, based on parameters of the latter, reveal good correlation near the equilibrium bond length for a group of diatomic molecules. Potential function relations, such as that shown in this paper, are useful when the preferred/reliable data is based on a potential function different from that adopted in available computational software. (orig.)

  14. Evaluation of the fluence to dose conversion coefficients for high energy neutrons using a voxel phantom coupled with the GEANT4 code

    CERN Document Server

    Paganini, S

    2005-01-01

    Crews working on present-day jet aircraft are a large occupationally exposed group with a relatively high average effective dose from Galactic cosmic radiation. Crews of future high-speed commercial flying at higher altitudes would be even more exposed. To help reduce the significant uncertainties in calculations of such exposures, the male adult voxels phantom MAX, developed in the Nuclear Energy Department of Pernambuco Federal University in Brazil, has been coupled with the Monte Carlo simulation code GEANT4. This toolkit, distributed and upgraded from the international scientific community of CERN/Switzerland, simulates thermal to ultrahigh energy neutrons transport and interactions in the matter. The high energy neutrons are pointed as the component that contribute about 70% of the neutron effective dose that represent the 35% to 60% total dose at aircraft altitude. In this research calculations of conversion coefficients from fluence to effective dose are performed for neutrons of energies from 100 MeV ...

  15. Advanced high conversion PWR: preliminary analysis

    International Nuclear Information System (INIS)

    Golfier, H.; Bellanger, V.; Bergeron, A.; Dolci, F.; Gastaldi, B.; Koberl, O.; Mignot, G.; Thevenot, C.

    2007-01-01

    In this paper, physical aspects of a HCPWR (High Conversion Light Water Reactor), which is an innovative PWR fuelled with mixed oxide and having a higher conversion ratio due to a lower moderation ratio. Moderation ratios lower than unity are considered which has led to low moderation PWR fuel assembly designs. The objectives of this parametric study are to define a feasibility area with regard to the following neutronic aspects: moderation ratio, Pu loading, reactor spectrum, irradiation time, and neutronic coefficients. Important thermohydraulic parameters are the pressure drop, the critical heat flux, the maximum temperature in the fuel rod and the pumping power. The thermohydraulic analysis shows that a range of moderation ratios from 0.8 to 1.2 is technically possible. A compromise between improved fuel utilization and research and development effort has been found for the moderation ration of about 1. The parametric study shows that there are 2 ranges of interest for the moderation ratio: -) moderation ratio between 0.8 and 1.2 with reduced fissile heights (> 3 m), hexagonal arrangement fuel assembly and square arrangement fuel assembly are possible; and -) moderation between 0.6 and 0.7 with a modification of the reactor operating conditions (reduction of the primary flow and of the thermal power), the fuel rods could be arranged inside a hexagonal fuel rod assembly. (A.C.)

  16. Modular approach for conversion to the ion-hybrid wave and α gyroresonance

    International Nuclear Information System (INIS)

    Kaufman, A.N.; Morehead, J.J.; Brizard, A.J.; Tracy, E.R.

    1997-01-01

    Linear conversion of an incoming magnetosonic wave (a.k.a. fast or compressional wave) to an ion-hybrid wave can be considered as a 3-step process in ray phase space. This is demonstrated by casting the cold-fluid model into the Friedland-Kaufman normal form for linear mode conversion. First, the incoming magnetosonic ray (MSR) converts a fraction of its action to an intermediate ion-hybrid ray (IHR), with the transmitted ray proceeding through the conversion layer. The IHR propagates in k-space to a second conversion point, where it converts in turn a fraction of its action into a reflected MSR, with the remainder of the its action constituting the converted IHR. The modular approach gives exact agreement with the more standard Budden formulation for the transmission, reflection and conversion coefficients, but has the important advantage of exposing the intermediate IHR. The existence of the intermediate IHR has important physical consequences as it can resonate with α particles. We estimate the time-integrated damping coefficient between the two conversions and show that ∫γdt is of order -100, thus the IH wave is completely annihilated between conversions and transfers its energy to the α close-quote s. This suggests that proposals to use the IH mode for current drive or DT heating are likely to fail in the presence of fusion α close-quote s. copyright 1997 American Institute of Physics

  17. Conversion of control systems, protection and engineering safeguard system signals of Almaraz NPP model from RELAP5 into TRAC-M

    International Nuclear Information System (INIS)

    Mulas, J.; Queral, C.; Collazo, I.; Concejal, A.; Burbano, N.; Lopez Lechas, A.; Tarrega, I.

    2002-01-01

    In the scope of a joint project between the Spanish Regulatory Commission (CSN) and the electric energy industry of Spain (UNESA) about the USNRC state-of-art thermal hydraulic code, TRAC-M, there is a task relating to the translation of the Spanish NPP models from other TH codes to the new one. As a part of this project, our team is working on the translation of Almaraz NPP model from RELAP5/MOD3.2 to TRAC-M. One of the goals of the project is to analyze the conversion of control blocks, signal variables and trips in order to correct modelling all instrumentation and control systems, and also protection and engineering safeguard system-signals of the NPP. At present, several portions of the input deck have been converted to TRAC-M, and the output data have also been compared with RELAP5 data. This paper describes the problems found in the conversion and the solutions achieved.(author)

  18. Coeficientes médios da equação de Angström-Prescott, radiação solar e evapotranspiração de referência em Brasília Angström-Prescott equation mean coefficients, solar radiation and reference crop evapotranspiration in Brasília

    Directory of Open Access Journals (Sweden)

    Karla Daniele e Silva Dornelas

    2006-08-01

    Full Text Available O objetivo deste trabalho foi estimar os coeficientes médios a e b da equação de Angström-Prescott, em Brasília, e seus efeitos sobre o cálculo da radiação solar global (Rs e da evapotranspiração de referência (ETo. Foram utilizados dados da estação meteorológica da Embrapa Hortaliças, do período de 1978 a 2003. Os coeficientes médios foram determinados por análise de regressão linear, no período todo e em períodos mensais e anuais. Utilizando-se o coeficiente calculado e os propostos pela FAO (0,25 e 0,50 estimaram-se Rs e ETo, e avaliaram-se os seus desempenhos. Os coeficientes médios mensais a variaram de 0,241 a 0,345, e b de 0,430 a 0,515. Os coeficientes médios anuais a e b foram 0,278 e 0,498, e os do período geral foram 0,282 e 0,490, respectivamente. A performance entre esses coeficientes na estimativa da radiação não diferiu. No mês de julho, foram verificados as piores estimativas e os piores desempenhos. Com as estimativas de Rs e os coeficientes médios calculados, as estimativas de ETo não diferiram dos observados, tendo-se constatado um ótimo desempenho, independentemente do coeficiente utilizado. Dependendo do tipo de aplicação final dos dados, recomenda-se utilizar, por sua simplicidade, os coeficientes médios obtidos para o período geral.The objective of this work was to estimate Angström-Prescott equation mean coefficients in Brasília, DF, Brazil, and their effects on the calculations of global radiation (Rs and reference crop evapotranspiration (ETo. It was used meteorological data from Embrapa Hortaliças weather station, from 1978 to 2003. The mean coefficients were determined by linear regression analysis considering monthly, annual and total periods. Using the calculated coefficients for different periods and those provided by FAO (0.25 and 0.50, Rs and ETo were estimated and their performances were evaluated. Monthly mean coefficient a varied from 0.241 to 0.345, and b from 0.430 to 0

  19. Analytical solution for the mode conversion equations with steep exponential density profiles

    International Nuclear Information System (INIS)

    Alava, M.J.; Heikkinen, J.A.

    1992-01-01

    A general analytical solution for the converted power from the fast magnetosonic wave to an ion Bernstein wave in a magnetized plasma with an exponential steeply increasing density profile is given in the closed form. The solution covers both the conversion at the lower-hybrid resonance and the conversion through the density gradient for small parallel wave numbers. As an application, the conversion coefficients at the scrape-off layer plasma are estimated in the context of ion cyclotron heating of a tokamak plasma

  20. Measurement and prediction of aromatic solute distribution coefficients for aqueous-organic solvent systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.R.; Luthy, R.G.

    1984-06-01

    Experimental and modeling activities were performed to assess techniques for measurement and prediction of distribution coefficients for aromatic solutes between water and immiscible organic solvents. Experiments were performed to measure distribution coefficients in both clean water and wastewater systems, and to assess treatment of a wastewater by solvent extraction. The theoretical portions of this investigation were directed towards development of techniques for prediction of solute-solvent/water distribution coefficients. Experiments were performed to assess treatment of a phenolic-laden coal conversion wastewater by solvent extraction. The results showed that solvent extraction for recovery of phenolic material offered several wastewater processing advantages. Distribution coefficients were measured in clean water and wastewater systems for aromatic solutes of varying functionality with different solvent types. It was found that distribution coefficients for these compounds in clean water systems were not statistically different from distribution coefficients determined in a complex coal conversion process wastewater. These and other aromatic solute distribution coefficient data were employed for evaluation of modeling techniques for prediction of solute-solvent/water distribution coefficients. Eight solvents were selected in order to represent various chemical classes: toluene and benzene (aromatics), hexane and heptane (alkanes), n-octanol (alcohols), n-butyl acetate (esters), diisopropyl ether (ethers), and methylisobutyl ketone (ketones). The aromatic solutes included: nonpolar compounds such as benzene, toluene and naphthalene, phenolic compounds such as phenol, cresol and catechol, nitrogenous aromatics such as aniline, pyridine and aminonaphthalene, and other aromatic solutes such as naphthol, quinolinol and halogenated compounds. 100 references, 20 figures, 34 tables.

  1. Converse flexoelectric effect in comb electrode piezoelectric microbeam

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Zhiyuan, E-mail: shenyuan675603@gmail.com [School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 Singapore (Singapore); Chen, Wei [Microelectronics Centre, School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 Singapore (Singapore)

    2012-04-09

    We demonstrate the converse flexoelectric effect in a lead zirconate titanate microbeam. The fringe electric field of a comb electrode induces converse flexoelectric responses in uniformly poled and depoled beams. The simulated electric field distribution shows that bending of the beam is induced by piezoelectric and μ{sub 11}, μ{sub 12} flexoelectric coefficients. Simulations indicate that piezoelectric displacement occurs in different directions in the two opposite poled samples while flexoelectric displacement remains the same. This finding is verified by the displacement measurement results. -- Highlights: ► We demonstrate the converse flexoelectric effect in a PZT microbeam. ► Beams with upward and downward poling states are fabricated by MEMS technique. ► Converse flexoelectric deformation is induced by the fringe field. ► Electric field distribution is calculated by finite element analysis. ► The simulation results are verified by impedance and displacement measurements.

  2. A software to edit voxel phantoms and to calculate conversion coefficients for radiation protection

    International Nuclear Information System (INIS)

    Vieira, J.W.; Stosic, B.; Lima, F.R.A.; Kramer, R.; Santos, A.M.; Lima, V.J.M.

    2005-01-01

    The MAX and FAX phantoms have been developed based on a male and female, respectively, adult body from ICRP and coupled to the Monte Carlo code (EGS4). These phantoms permit the calculating of the equivalent dose in organs and tissues of the human body for the radiation protection purposes . In the constructing of these anthropomorphic models, the software developed called FANTOMAS, which performs tasks as file format conversion, filtering 2D and 3D images, exchange of identifying numbers of organs, body mass adjustments based in volume, resampling of 2D and 3D images, resize images, preview consecutive slices of the phantom, running computational models of exposure FANTOMA/EGS4 and viewing graphics of conversion factors between equivalent dose and a measurable dosimetric quantity. This paper presents the main abilities of FANTOMAS and uses the MAX and/or FAX to exemplify some procedures

  3. Microwave plasma mode conversion

    International Nuclear Information System (INIS)

    Torres, H.S.; Sakanaka, P.H.; Villarroel, C.H.

    1985-01-01

    The behavior of hot electrons during the process of laser-produced plasma is studied. The basic equations of mode conversion from electromagnetic waves to electrostatic waves are presented. It is shown by mode conversion, that, the resonant absorption and parametric instabilities appear simultaneously, but in different plasma regions. (M.C.K.) [pt

  4. Development and application of a complex numerical model and software for the computation of dose conversion factors for radon progenies.

    Science.gov (United States)

    Farkas, Árpád; Balásházy, Imre

    2015-04-01

    A more exact determination of dose conversion factors associated with radon progeny inhalation was possible due to the advancements in epidemiological health risk estimates in the last years. The enhancement of computational power and the development of numerical techniques allow computing dose conversion factors with increasing reliability. The objective of this study was to develop an integrated model and software based on a self-developed airway deposition code, an own bronchial dosimetry model and the computational methods accepted by International Commission on Radiological Protection (ICRP) to calculate dose conversion coefficients for different exposure conditions. The model was tested by its application for exposure and breathing conditions characteristic of mines and homes. The dose conversion factors were 8 and 16 mSv WLM(-1) for homes and mines when applying a stochastic deposition model combined with the ICRP dosimetry model (named PM-A model), and 9 and 17 mSv WLM(-1) when applying the same deposition model combined with authors' bronchial dosimetry model and the ICRP bronchiolar and alveolar-interstitial dosimetry model (called PM-B model). User friendly software for the computation of dose conversion factors has also been developed. The software allows one to compute conversion factors for a large range of exposure and breathing parameters and to perform sensitivity analyses. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. On the Decrease of the Oceanic Drag Coefficient in High Winds

    Science.gov (United States)

    Donelan, Mark A.

    2018-02-01

    The sheltering coefficient - prefixing Jeffreys' concept of the exponential wave growth rate at a gas-liquid interface - is shown to be Reynolds number dependent from laboratory measurements of waves and Reynolds stresses. There are two turbulent flow regimes: wind speed range of 2.5 to 30 m/s where the drag coefficients increase with wind speed, and wind speed range of 30 to 50 m/s where sheltering/drag coefficients decrease/saturate with wind speed. By comparing model calculations of drag coefficients - using a fixed sheltering coefficient - with ocean observations over a wind speed range of 1 to 50 m/s a similar Reynolds number dependence of the oceanic sheltering coefficient is revealed. In consequence the drag coefficient is a function of Reynolds number and wave age, and not just wind speed as frequently assumed. The resulting decreasing drag coefficient above 30 m/s is shown to be critical in explaining the rapid intensification so prominent in the climatology of Atlantic hurricanes. The Reynolds number dependence of the sheltering coefficient, when employed in coupled models, should lead to significant improvements in the prediction of intensification and decay of tropical cyclones. A calculation of curvature at the wave crest suggests that at wind speeds above 56.15 m/s all waves-breaking or not-induce steady flow separation leading to a minimum in the drag coefficient. This is further evidence of the veracity of the observations of the oceanic drag coefficient at high winds.

  6. CH3CO + O2 + M (M = He, N2) Reaction Rate Coefficient Measurements and Implications for the OH Radical Product Yield.

    Science.gov (United States)

    Papadimitriou, Vassileios C; Karafas, Emmanuel S; Gierczak, Tomasz; Burkholder, James B

    2015-07-16

    The gas-phase CH3CO + O2 reaction is known to proceed via a chemical activation mechanism leading to the formation of OH and CH3C(O)OO radicals via bimolecular and termolecular reactive channels, respectively. In this work, rate coefficients, k, for the CH3CO + O2 reaction were measured over a range of temperature (241-373 K) and pressure (0.009-600 Torr) with He and N2 as the bath gas and used to characterize the bi- and ter-molecular reaction channels. Three independent experimental methods (pulsed laser photolysis-laser-induced fluorescence (PLP-LIF), pulsed laser photolysis-cavity ring-down spectroscopy (PLP-CRDS), and a very low-pressure reactor (VLPR)) were used to characterize k(T,M). PLP-LIF was the primary method used to measure k(T,M) in the high-pressure regime under pseudo-first-order conditions. CH3CO was produced by PLP, and LIF was used to monitor the OH radical bimolecular channel reaction product. CRDS, a complementary high-pressure method, measured k(295 K,M) over the pressure range 25-600 Torr (He) by monitoring the temporal CH3CO radical absorption following its production via PLP in the presence of excess O2. The VLPR technique was used in a relative rate mode to measure k(296 K,M) in the low-pressure regime (9-32 mTorr) with CH3CO + Cl2 used as the reference reaction. A kinetic mechanism analysis of the combined kinetic data set yielded a zero pressure limit rate coefficient, kint(T), of (6.4 ± 4) × 10(-14) exp((820 ± 150)/T) cm(3) molecule(-1) s(-1) (with kint(296 K) measured to be (9.94 ± 1.3) × 10(-13) cm(3) molecule(-1) s(-1)), k0(T) = (7.39 ± 0.3) × 10(-30) (T/300)(-2.2±0.3) cm(6) molecule(-2) s(-1), and k∞(T) = (4.88 ± 0.05) × 10(-12) (T/300)(-0.85±0.07) cm(3) molecule(-1) s(-1) with Fc = 0.8 and M = N2. A He/N2 collision efficiency ratio of 0.60 ± 0.05 was determined. The phenomenological kinetic results were used to define the pressure and temperature dependence of the OH radical yield in the CH3CO + O2 reaction. The

  7. Tritons at energies of 10 MeV to 1 TeV: Conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose, and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C

    International Nuclear Information System (INIS)

    Copeland, K.; Parker, D. E.; Friedberg, W.

    2010-01-01

    Conversion coefficients were calculated for fluence-to-absorbed dose, fluence-to-equivalent dose, fluence-to-effective dose and fluence-to-gray equivalent for isotropic exposure of an adult female and an adult male to tritons ( 3 H + ) in the energy range of 10 MeV to 1 TeV (0.01-1000 GeV). Coefficients were calculated using Monte Carlo transport code MCNPX 2.7.C and BodyBuilder TM 1.3 anthropomorphic phantoms. Phantoms were modified to allow calculation of effective dose to a Reference Person using tissues and tissue weighting factors from 1990 and 2007 recommendations of the International Commission on Radiological Protection (ICRP) and calculation of gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. At 15 of the 19 energies for which coefficients for effective dose were calculated, coefficients based on ICRP 2007 and 1990 recommendations differed by less than 3%. The greatest difference, 43%, occurred at 30 MeV. Published by Oxford Univ. Press on behalf of the US Government 2010. (authors)

  8. Engineering quadratic nonlinear photonic crystals for frequency conversion of lasers

    Science.gov (United States)

    Chen, Baoqin; Hong, Lihong; Hu, Chenyang; Zhang, Chao; Liu, Rongjuan; Li, Zhiyuan

    2018-03-01

    Nonlinear frequency conversion offers an effective way to extend the laser wavelength range. Quadratic nonlinear photonic crystals (NPCs) are artificial materials composed of domain-inversion structures whose sign of nonlinear coefficients are modulated with desire to implement quasi-phase matching (QPM) required for nonlinear frequency conversion. These structures can offer various reciprocal lattice vectors (RLVs) to compensate the phase-mismatching during the quadratic nonlinear optical processes, including second-harmonic generation (SHG), sum-frequency generation and the cascaded third-harmonic generation (THG). The modulation pattern of the nonlinear coefficients is flexible, which can be one-dimensional or two-dimensional (2D), be periodic, quasi-periodic, aperiodic, chirped, or super-periodic. As a result, these NPCs offer very flexible QPM scheme to satisfy various nonlinear optics and laser frequency conversion problems via design of the modulation patterns and RLV spectra. In particular, we introduce the electric poling technique for fabricating QPM structures, a simple effective nonlinear coefficient model for efficiently and precisely evaluating the performance of QPM structures, the concept of super-QPM and super-periodically poled lithium niobate for finely tuning nonlinear optical interactions, the design of 2D ellipse QPM NPC structures enabling continuous tunability of SHG in a broad bandwidth by simply changing the transport direction of pump light, and chirped QPM structures that exhibit broadband RLVs and allow for simultaneous radiation of broadband SHG, THG, HHG and thus coherent white laser from a single crystal. All these technical, theoretical, and physical studies on QPM NPCs can help to gain a deeper insight on the mechanisms, approaches, and routes for flexibly controlling the interaction of lasers with various QPM NPCs for high-efficiency frequency conversion and creation of novel lasers.

  9. Comparison of field-measured radon diffusion coefficients with laboratory-measured coefficients

    International Nuclear Information System (INIS)

    Lepel, E.A.; Silker, W.B.; Thomas, V.W.; Kalkwarf, D.R.

    1983-04-01

    Experiments were conducted to compare radon diffusion coefficients determined for 0.1-m depths of soils by a steady-state method in the laboratory and diffusion coefficients evaluated from radon fluxes through several-fold greater depths of the same soils covering uranium-mill tailings. The coefficients referred to diffusion in the total pore volume of the soils and are equivalent to values for the quantity, D/P, in the Generic Environmental Impact Statement on Uranium Milling prepared by the US Nuclear Regulatory Commission. Two soils were tested: a well-graded sand and an inorganic clay of low plasticity. For the flux evaluations, radon was collected by adsorption on charcoal following passive diffusion from the soil surface and also from air recirculating through an aluminum tent over the soil surface. An analysis of variance in the flux evaluations showed no significant difference between these two collection methods. Radon diffusion coefficients evaluated from field data were statistically indistinguishable, at the 95% confidence level, from those measured in the laboratory; however, the low precision of the field data prevented a sensitive validation of the laboratory measurements. From the field data, the coefficients were calculated to be 0.03 +- 0.03 cm 2 /s for the sand cover and 0.0036 +- 0.0004 cm 2 /s for the clay cover. The low precision in the coefficients evaluated from field data was attributed to high variation in radon flux with time and surface location at the field site

  10. Maximum Efficiency of Thermoelectric Heat Conversion in High-Temperature Power Devices

    Directory of Open Access Journals (Sweden)

    V. I. Khvesyuk

    2016-01-01

    Full Text Available Modern trends in development of aircraft engineering go with development of vehicles of the fifth generation. The features of aircrafts of the fifth generation are motivation to use new high-performance systems of onboard power supply. The operating temperature of the outer walls of engines is of 800–1000 K. This corresponds to radiation heat flux of 10 kW/m2 . The thermal energy including radiation of the engine wall may potentially be converted into electricity. The main objective of this paper is to analyze if it is possible to use a high efficiency thermoelectric conversion of heat into electricity. The paper considers issues such as working processes, choice of materials, and optimization of thermoelectric conversion. It presents the analysis results of operating conditions of thermoelectric generator (TEG used in advanced hightemperature power devices. A high-temperature heat source is a favorable factor for the thermoelectric conversion of heat. It is shown that for existing thermoelectric materials a theoretical conversion efficiency can reach the level of 15–20% at temperatures up to 1500 K and available values of Ioffe parameter being ZT = 2–3 (Z is figure of merit, T is temperature. To ensure temperature regime and high efficiency thermoelectric conversion simultaneously it is necessary to have a certain match between TEG power, temperature of hot and cold surfaces, and heat transfer coefficient of the cooling system. The paper discusses a concept of radiation absorber on the TEG hot surface. The analysis has demonstrated a number of potentialities for highly efficient conversion through using the TEG in high-temperature power devices. This work has been implemented under support of the Ministry of Education and Science of the Russian Federation; project No. 1145 (the programme “Organization of Research Engineering Activities”.

  11. Absorption and emission from mode conversion theory

    International Nuclear Information System (INIS)

    Swanson, D.G.

    1995-02-01

    The effects of mode conversion theory on emission have led to some surprising results. The classical expressions were originally derived from models which did not include mode conversion or its attendant reflection. When mode conversion was included, the first surprise was that the transmission coefficient is totally independent of absorption and due exclusively to tunneling. The other surprise is that the observed emission arises from two distinct sources, one direct, and one from an indirect Bernstein wave source which is partially converted in the cyclotron layer to outgoing electromagnetic waves, with the net result that mode conversion cancels out for the electron case. The only corrections to electron cyclotron emission are then due to reflection effects, and these have been shown to be small for laboratory plasmas, leading to the validation of the classical formula, but via an entirely new paradigm in its interpretation. This paper includes a summary of the absorption process for electron cyclotron harmonics, and reviews the emission physics, including both potential error estimates and a discussion of the spatial emission source distribution

  12. Heat transfer coefficient of cryotop during freezing.

    Science.gov (United States)

    Li, W J; Zhou, X L; Wang, H S; Liu, B L; Dai, J J

    2013-01-01

    Cryotop is an efficient vitrification method for cryopreservation of oocytes. It has been widely used owing to its simple operation and high freezing rate. Recently, the heat transfer performance of cryotop was studied by numerical simulation in several studies. However, the range of heat transfer coefficient in the simulation is uncertain. In this study, the heat transfer coefficient for cryotop during freezing process was analyzed. The cooling rates of 40 percent ethylene glycol (EG) droplet in cryotop during freezing were measured by ultra-fast measurement system and calculated by numerical simulation at different value of heat transfer coefficient. Compared with the results obtained by two methods, the range of the heat transfer coefficient necessary for the numerical simulation of cryotop was determined, which is between 9000 W/(m(2)·K) and 10000 W/(m (2)·K).

  13. Penetration effect in internal conversion and nuclear structure

    International Nuclear Information System (INIS)

    Listengarten, M.A.

    1978-01-01

    The conditions for the appearance of the anomalous internal conversion coefficients (ICC) are considered, when the contribution of the penetration matrix element (PME) is of the order of or larger than the main part of the conversion matrix element. The experimental magnitudes of the nuclear PME agree well with those calculated in the framework of simple nuclear models, provided the magnitude of PME is not decreased due to the model -dependent selection rules. The magnitude of the anomaly ( lanbda parameter ) is compared with the exclusion factor of γ-transition relative to the Weisskopf estimation. The better is the model of the nucleus the weaker is the dependence of the lambda magnitude on the exclusion factor. ICC coefficients might be anomalous for those γ-transitions for which the exclusion factor calculated in the framework of more rigorous model are of the order of unity. In the ''ideal'' model of nucleus completely adequate to the true nuclear structure the dependence of the lambda penetration parameter on the exclusion factor vanishes

  14. Defining the Ecological Coefficient of Performance for an Aircraft Propulsion System

    Science.gov (United States)

    Şöhret, Yasin

    2018-05-01

    The aircraft industry, along with other industries, is considered responsible these days regarding environmental issues. Therefore, the performance evaluation of aircraft propulsion systems should be conducted with respect to environmental and ecological considerations. The current paper aims to present the ecological coefficient of performance calculation methodology for aircraft propulsion systems. The ecological coefficient performance is a widely-preferred performance indicator of numerous energy conversion systems. On the basis of thermodynamic laws, the methodology used to determine the ecological coefficient of performance for an aircraft propulsion system is parametrically explained and illustrated in this paper for the first time. For a better understanding, to begin with, the exergy analysis of a turbojet engine is described in detail. Following this, the outputs of the analysis are employed to define the ecological coefficient of performance for a turbojet engine. At the end of the study, the ecological coefficient of performance is evaluated parametrically and discussed depending on selected engine design parameters and performance measures. The author asserts the ecological coefficient of performance to be a beneficial indicator for researchers interested in aircraft propulsion system design and related topics.

  15. A gain-coefficient switched Alexandrite laser

    International Nuclear Information System (INIS)

    Lee, Chris J; Van der Slot, Peter J M; Boller, Klaus-J

    2013-01-01

    We report on a gain-coefficient switched Alexandrite laser. An electro-optic modulator is used to switch between high and low gain states by making use of the polarization dependent gain of Alexandrite. In gain-coefficient switched mode, the laser produces 85 ns pulses with a pulse energy of 240 mJ at a repetition rate of 5 Hz.

  16. Effects of a random spatial variation of the plasma density on the mode conversion in cold, unmagnetized, and stratified plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Jung Yu, Dae [School of Space Research, Kyung Hee University, Yongin 446-701 (Korea, Republic of); Kim, Kihong [Department of Energy Systems Research, Ajou University, Suwon 443-749 (Korea, Republic of)

    2013-12-15

    We study the effects of a random spatial variation of the plasma density on the mode conversion of electromagnetic waves into electrostatic oscillations in cold, unmagnetized, and stratified plasmas. Using the invariant imbedding method, we calculate precisely the electromagnetic field distribution and the mode conversion coefficient, which is defined to be the fraction of the incident wave power converted into electrostatic oscillations, for the configuration where a numerically generated random density variation is added to the background linear density profile. We repeat similar calculations for a large number of random configurations and take an average of the results. We obtain a peculiar nonmonotonic dependence of the mode conversion coefficient on the strength of randomness. As the disorder increases from zero, the maximum value of the mode conversion coefficient decreases initially, then increases to a maximum, and finally decreases towards zero. The range of the incident angle in which mode conversion occurs increases monotonically as the disorder increases. We present numerical results suggesting that the decrease of mode conversion mainly results from the increased reflection due to the Anderson localization effect originating from disorder, whereas the increase of mode conversion of the intermediate disorder regime comes from the appearance of many resonance points and the enhanced tunneling between the resonance points and the cutoff point. We also find a very large local enhancement of the magnetic field intensity for particular random configurations. In order to obtain high mode conversion efficiency, it is desirable to restrict the randomness close to the resonance region.

  17. Effects of a random spatial variation of the plasma density on the mode conversion in cold, unmagnetized, and stratified plasmas

    International Nuclear Information System (INIS)

    Jung Yu, Dae; Kim, Kihong

    2013-01-01

    We study the effects of a random spatial variation of the plasma density on the mode conversion of electromagnetic waves into electrostatic oscillations in cold, unmagnetized, and stratified plasmas. Using the invariant imbedding method, we calculate precisely the electromagnetic field distribution and the mode conversion coefficient, which is defined to be the fraction of the incident wave power converted into electrostatic oscillations, for the configuration where a numerically generated random density variation is added to the background linear density profile. We repeat similar calculations for a large number of random configurations and take an average of the results. We obtain a peculiar nonmonotonic dependence of the mode conversion coefficient on the strength of randomness. As the disorder increases from zero, the maximum value of the mode conversion coefficient decreases initially, then increases to a maximum, and finally decreases towards zero. The range of the incident angle in which mode conversion occurs increases monotonically as the disorder increases. We present numerical results suggesting that the decrease of mode conversion mainly results from the increased reflection due to the Anderson localization effect originating from disorder, whereas the increase of mode conversion of the intermediate disorder regime comes from the appearance of many resonance points and the enhanced tunneling between the resonance points and the cutoff point. We also find a very large local enhancement of the magnetic field intensity for particular random configurations. In order to obtain high mode conversion efficiency, it is desirable to restrict the randomness close to the resonance region

  18. Full-spectrum volumetric solar thermal conversion via photonic nanofluids.

    Science.gov (United States)

    Liu, Xianglei; Xuan, Yimin

    2017-10-12

    Volumetric solar thermal conversion is an emerging technique for a plethora of applications such as solar thermal power generation, desalination, and solar water splitting. However, achieving broadband solar thermal absorption via dilute nanofluids is still a daunting challenge. In this work, full-spectrum volumetric solar thermal conversion is demonstrated over a thin layer of the proposed 'photonic nanofluids'. The underlying mechanism is found to be the photonic superposition of core resonances, shell plasmons, and core-shell resonances at different wavelengths, whose coexistence is enabled by the broken symmetry of specially designed composite nanoparticles, i.e., Janus nanoparticles. The solar thermal conversion efficiency can be improved by 10.8% compared with core-shell nanofluids. The extinction coefficient of Janus dimers with various configurations is also investigated to unveil the effects of particle couplings. This work provides the possibility to achieve full-spectrum volumetric solar thermal conversion, and may have potential applications in efficient solar energy harvesting and utilization.

  19. On the Energy Conversion Efficiency of Piezoelectric Vibration Energy Harvesting Devices

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Eun [Catholic University of Daegu, Kyungsan (Korea, Republic of)

    2015-05-15

    To properly design and assess a piezoelectric vibration energy harvester, it is necessary to consider the application of an efficiency measure of energy conversion. The energy conversion efficiency is defined in this work as the ratio of the electrical output power to the mechanical input power for a piezoelectric vibration energy harvester with an impedance-matched load resistor. While previous research works employed the electrical output power for approximate impedance-matched load resistance, this work derives an efficiency measure considering optimally matched resistance. The modified efficiency measure is validated by comparing it with finite element analysis results for piezoelectric vibration energy harvesters with three different values of the electro-mechanical coupling coefficient. New findings on the characteristics of energy conversion and conversion efficiency are also provided for the two different impedance matching methods.

  20. Calculation of conversion coefficients for effective dose by using voxel phantoms with defined genus for radiodiagnostic common examinations

    International Nuclear Information System (INIS)

    Lima, F.R.A.; Kramer, R.; Khoury, H.J.; Vieira, J.W.; Loureiro, E.C.M.; Hoff, G.

    2004-01-01

    Patient exposure from radiological examinations is usually quantified in terms of average absorbed dose or equivalent dose to certain radiosensitive organs of the human body. As these quantities cannot be measured in vivo, it is common practice to use physical or computational exposure models, which simulate the exposure to the patient in order to determine not only the quantities of interest (absorbed or equivalent dose), but also at the same time measurable quantities for the exposure conditions given. The ratio between a quantity of interest and a measurable quantity is called a conversion coefficient (CC), which is a function of the source and field parameters (tube voltage, filtration, field size, field position, focus-to-skin distance, etc.), the anatomical properties of the phantom, the elemental composition of relevant body tissues, and the radiation transport method applied. As the effective dose represents a sum over 23 risk-weighted organ and tissue equivalent doses, its determination practically implies the measurement or calculation of a complete distribution of equivalent doses throughout the human body. This task can be resolved most efficiently by means of computational exposure models, which consist of a virtual representation of the human body, also called phantom, connected to a Monte Carlo radiation transport computer code. The recently introduced MAX (Male Adult voXel) and FAXht (Female Adult voXel) head+trunk phantoms have been chosen for this task. With respect to their anatomical properties these phantoms correspond fairly well to the data recommended by the ICRP for the Reference Adult Male and Female. (author)

  1. Laser-accelerated proton conversion efficiency thickness scaling

    International Nuclear Information System (INIS)

    Hey, D. S.; Foord, M. E.; Key, M. H.; LePape, S. L.; Mackinnon, A. J.; Patel, P. K.; Ping, Y.; Akli, K. U.; Stephens, R. B.; Bartal, T.; Beg, F. N.; Fedosejevs, R.; Friesen, H.; Tiedje, H. F.; Tsui, Y. Y.

    2009-01-01

    The conversion efficiency from laser energy into proton kinetic energy is measured with the 0.6 ps, 9x10 19 W/cm 2 Titan laser at the Jupiter Laser Facility as a function of target thickness in Au foils. For targets thicker than 20 μm, the conversion efficiency scales approximately as 1/L, where L is the target thickness. This is explained by the domination of hot electron collisional losses over adiabatic cooling. In thinner targets, the two effects become comparable, causing the conversion efficiency to scale weaker than 1/L; the measured conversion efficiency is constant within the scatter in the data for targets between 5 and 15 μm, with a peak conversion efficiency of 4% into protons with energy greater than 3 MeV. Depletion of the hydrocarbon contaminant layer is eliminated as an explanation for this plateau by using targets coated with 200 nm of ErH 3 on the rear surface. The proton acceleration is modeled with the hybrid-particle in cell code LSP, which reproduced the conversion efficiency scaling observed in the data.

  2. Role of nuclear penetration effects in spin assignments. [J, transitions, internal conversion

    Energy Technology Data Exchange (ETDEWEB)

    Sahota, H S [Punjabi Univ., Patiala (India). Dept. of Physics

    1976-04-01

    Nuclear penetrations have been found to affect the internal conversion process of the retarded magnetic dipole transitions. In all cases where the penetration coefficient has been found to be essentially different from unity the transition is 1-forbidden. This criterian has been applied to the case of 191 keV transition in /sup 197/Au where the spin of the 268 keV level could not be deduced uniquely by any of the existing methods. The result is that the 199 keV transition has a dynamic contribution to its internal conversion process with the penetration coefficient lambda = 5.5 +- 0.9. To illustrate the applicability of the criterian further two more cases namely that of the 92 keV transition in /sup 131/Cs and 182 keV transition in /sup 129/Cs are also included.

  3. Helions at energies of 10 MeV to 1 TeV: Conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C

    International Nuclear Information System (INIS)

    Copeland, K.; Parker, D. E.; Friedberg, W.

    2010-01-01

    Conversion coefficients were calculated for fluence-to-absorbed dose, fluence-to-equivalent dose, fluence-to-effective dose and fluence-to-gray equivalent, for isotropic exposure of an adult male and an adult female to helions ( 3 He 2+ ) in the energy range of 10 MeV to 1 TeV (0.01-1000 GeV). Calculations were performed using Monte Carlo transport code MCNPX 2.7.C and BodyBuilder TM 1.3 anthropomorphic phantoms modified to allow calculation of effective dose using tissues and tissue weighting factors from either the 1990 or 2007 recommendations of the International Commission on Radiological Protection (ICRP), and gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. At 15 of the 19 energies for which coefficients for effective dose were calculated, coefficients based on ICRP 2007 and 1990 recommendations differed by less than 2%. The greatest difference, 62%, occurred at 100 MeV. Published by Oxford Univ. Press on behalf of the U.S. Government 2010. (authors)

  4. Generalized heat kernel coefficients for a new asymptotic expansion

    International Nuclear Information System (INIS)

    Osipov, Alexander A.; Hiller, Brigitte

    2003-01-01

    The method which allows for asymptotic expansion of the one-loop effective action W = lndetA is formulated. The positively defined elliptic operator A = U + M2 depends on the external classical fields taking values in the Lie algebra of the internal symmetry group G. Unlike the standard method of Schwinger - DeWitt, the more general case with the nongenerate mass matrix M = diag(m1, m2, ...) is considered. The first coefficients of the new asymptotic series are calculated and their relationship with the Seeley - DeWitt coefficients is clarified

  5. Ortho-para-H2 conversion by hydrogen exchange: comparison of theory and experiment.

    Science.gov (United States)

    Lique, François; Honvault, Pascal; Faure, Alexandre

    2012-10-21

    We report fully-quantum time-independent calculations of cross sections and rate coefficients for the collisional (de)excitation of H(2) by H. Our calculations are based on the H(3) global potential energy surface of Mielke et al. [J. Chem. Phys. 116, 4142 (2002)]. The reactive hydrogen exchange channels are taken into account. We show that the ortho-para and para-ortho conversion of H(2) are significant processes at temperatures above ~300 K and for the last process we provide the first comparison with available experimental rate coefficients between 300 and 444 K. The good agreement between theory and experiment is a new illustration of our detailed understanding of the simplest chemical reaction. The importance of the ortho-para-H(2) conversion by hydrogen exchange in astrophysics is discussed.

  6. M-MRAC Backstepping for Systems with Unknown Virtual Control Coefficients

    Science.gov (United States)

    Stepanyan, Vahram; Krishnakumar, Kalmanje

    2015-01-01

    The paper presents an over-parametrization free certainty equivalence state feedback backstepping adaptive control design method for systems of any relative degree with unmatched uncertainties and unknown virtual control coefficients. It uses a fast prediction model to estimate the unknown parameters, which is independent of the control design. It is shown that the system's input and output tracking errors can be systematically decreased by the proper choice of the design parameters. The benefits of the approach are demonstrated in numerical simulations.

  7. Experimental Investigations of Direct and Converse Flexoelectric Effect in Bilayer Lipid Membranes.

    Science.gov (United States)

    Todorov, Angelio Todorov

    Flexoelectric coefficients (direct and converse), electric properties (capacitance and resistivity) and mechanical properties (thickness and elastic coefficients) have been determined for bilayer lipid membranes (BLMs) prepared from egg yolk lecithin (EYL), glycerol monoleate (GMO), phosphatidyl choline (PC) and phosphatidyl serine (PS) as a function of frequency, pH and surface charge modifiers. Direct flexoelectric effect manifested itself in the development of microvolt range a.c. potential (U_{f}) upon subjecting one side of a BLM to an oscillating hydrostatic pressure, in the 100-1000 Hz range. Operationally, the flexoelectric coefficient (f) is expressed by the ratio between U_{f} and the change of curvature (c) which accompanied the flexing of the membrane. Membrane curvature was determined by means of either the electric method (capacitance microphone effect) or by the newly developed method of stroboscopic interferometry. Real-time stroboscopic interferometry coupled with simultaneous electric measurements, provided a direct method for the determination of f. Two different frequency regimes of f were recognized. At low frequencies (300 Hz), associated with free mobility of the surfactant, f-values of 24.1 times 10^{-19} and 0.87 times 10^ {-19} Coulombs were obtained for PC and GMO BLMs. At high frequencies (>300 Hz), associated with blocked mobility of the surfactant, f-values of 16.5 times 10^ {-19} and 0.30 times 10^{-19} Coulombs were obtained for PC and GMO BLMs. The theoretically calculated value for the GMO BLM oscillating at high frequency (0.12 times 10^{-19 } Coulombs) agreed well with that determined experimentally (0.3 times 10 ^{-19} Coulombs). For charged bovine brain PS BLM the observed flexocoefficient was f = 4.0 times 10^{ -18} Coulombs. Converse flexoelectric effect manifested itself in voltage-induced BLM curvature. Observations were carried out on uranyl acetate (UA) stabilized PS BLM under a.c. excitation. Frequency dependence of f

  8. Conversion Factors for Predicting Unshielded Dose Rates in Shielded Waste

    International Nuclear Information System (INIS)

    Clapham, M.; Seamans Jr, J.V.; Arbon, R.E.

    2009-01-01

    This document describes the methodology developed and used by the Advanced Mixed Waste Treatment Project for determining the activity content and the unshielded surface dose rate for lead lined containers contaminated with transuranic waste. Several methods were investigated: - Direct measurement of the dose rate after removing the shielding. - Use of a MicroShield R derived dose conversion factor, (mRem/hr unshielded )/(mRem/hr shielded ), applied to the measured surface dose rate to estimate the unshielded surface dose rate. - Use of a MicroShield R derived activity conversion factor, mRem/hr unshielded /Ci, applied to the measured activity to estimate the unshielded dose rate. - Use of an empirically derived activity conversion factor, mRem/hr unshielded /Ci, applied to the measured activity to estimate the unshielded dose rate. The last approach proved to be the most efficacious by using a combination of nondestructive assay and empirically defined dose rate conversion factors. Empirically derived conversion factors were found to be highly dependent upon the matrix of the waste. Use of conversion factors relied on activity values corrected to address the presence of a lead liner. (authors)

  9. X-ray-to-current signal conversion characteristics of trench-structured photodiodes for direct-conversion-type silicon X-ray sensor

    International Nuclear Information System (INIS)

    Ariyoshi, Tetsuya; Funaki, Shota; Sakamoto, Kenji; Baba, Akiyoshi; Arima, Yutaka

    2017-01-01

    To reduce the radiation dose required in medical X-ray diagnoses, we propose a high-sensitivity direct-conversion-type silicon X-ray sensor that uses trench-structured photodiodes. This sensor is advantageous in terms of its long device lifetime, noise immunity, and low power consumption because of its low bias voltage. With this sensor, it is possible to detect X-rays with almost 100% efficiency; sensitivity can therefore be improved by approximately 10 times when compared with conventional indirect-conversion-type sensors. In this study, a test chip was fabricated using a single-poly single-metal 0.35 μm process. The formed trench photodiodes for the X-ray sensor were approximately 170 and 300 μm deep. At a bias voltage of 25 V, the absorbed X-ray-to-current signal conversion efficiencies were 89.3% (theoretical limit; 96.7%) at a trench depth of 170 μm and 91.1% (theoretical limit; 94.3%) at a trench depth of 300 μm. (author)

  10. Diffusion coefficients of paracetamol in aqueous solutions

    International Nuclear Information System (INIS)

    Ribeiro, Ana C.F.; Barros, Marisa C.F.; Veríssimo, Luís M.P.; Santos, Cecilia I.A.V.; Cabral, Ana M.T.D.P.V.; Gaspar, Gualter D.; Esteso, Miguel A.

    2012-01-01

    Highlights: ► Mutual diffusion coefficients of paracetamol in aqueous dilute solutions. ► Influence of the thermodynamic factors on the variation of their mutual diffusion coefficients. ► Estimation of the mutual limiting diffusion coefficients of the molecular, D m 0 , and ionized forms, D ± 0 , of this drug. - Abstract: Binary mutual diffusion coefficients measured by the Taylor dispersion method, for aqueous solutions of paracetamol (PA) at concentrations from (0.001 to 0.050) mol·dm −3 at T = 298.15 K, are reported. From the Nernst–Hartley equation and our experimental results, the limiting diffusion coefficient of this drug and its thermodynamic factors are estimated, thereby contributing in this way to a better understanding of the structure of such systems and of their thermodynamic behaviour in aqueous solution at different concentrations.

  11. Theory of mind understanding and conversational patterns in middle childhood.

    Science.gov (United States)

    Bosacki, Sandra Leanne

    2013-01-01

    The author investigated the longitudinal relations between theory of mind (ToM) understanding and perceptions of self and social conversations in 17 school-aged children (12 girls, 5 boys, age 8-12 years). ToM was assessed at Time 1 (T1; M age = 8 years 5 months, SD = 8.7 months, and perceptions of self and conversational experiences assessed two years later at Time 2 (T2; M age = 10 years 4 months, SD = 7.9 months. Most importantly, longitudinal findings showed that children who scored relatively high on ToM at T1 reported relatively lower perceptions of self-worth and higher number of mental states verbs in their perceptions of peer and family conversations at T2. Significant negative longitudinal associations were found between children's number of siblings and their perceptions of self-worth (T1) and number of cognitive terms in their perceptions of peer and family conversations (T2). Frequency analysis suggested that girls' perceptions of conversations referred to more social and psychological aspects of self and relationships, whereas boys focused mainly on physical activities. Most children were more likely to prefer listening to talking during social conversations. The majority of children reported feelings of mixed or ambiguous emotions during experiences of silence. Implications for socioemotional and cognitive development in early adolescents are discussed.

  12. Ortho-para H₂ conversion by proton exchange at low temperature: an accurate quantum mechanical study.

    Science.gov (United States)

    Honvault, P; Jorfi, M; González-Lezana, T; Faure, A; Pagani, L

    2011-07-08

    We report extensive, accurate fully quantum, time-independent calculations of cross sections at low collision energies, and rate coefficients at low temperatures for the H⁺ + H₂(v = 0, j) → H⁺ + H₂(v = 0, j') reaction. Different transitions are considered, especially the ortho-para conversion (j = 1 → j' = 0) which is of key importance in astrophysics. This conversion process appears to be very efficient and dominant at low temperature, with a rate coefficient of 4.15 × 10⁻¹⁰ cm³ molecule⁻¹ s⁻¹ at 10 K. The quantum mechanical results are also compared with statistical quantum predictions and the reaction is found to be statistical in the low temperature regime (T < 100 K).

  13. Pearson's correlation coefficient in the theory of networks: A comment

    OpenAIRE

    Ahmed, Zafar; Kumar, Sachin

    2018-01-01

    In statistics, the Pearson correlation coefficient $r_{x,y}$ determines the degree of linear correlation between two variables and it is known that $-1 \\le r_{x,y} \\le 1$. In the theory of networks, a curious expression proposed in [PRL {\\bf 89} 208701 (2002)] for degree-degree correlation coefficient $r_{j_i,k_i}, i\\in [1,M]$ has been in use. We realize that the suggested form is the conventional Pearson's coefficient for $\\{(j_i,k_i), (k_i,j_i)\\}$ for $2M$ data points and hence it is rightl...

  14. Iron disulfide for solar energy conversion

    Energy Technology Data Exchange (ETDEWEB)

    Ennaoui, A. (Hahn-Meitner-Inst., Abt. Solare Energetik und Materialforschung, Berlin (Germany)); Fiechter, S. (Hahn-Meitner-Inst., Abt. Solare Energetik und Materialforschung, Berlin (Germany)); Pettenkofer, C. (Hahn-Meitner-Inst., Abt. Solare Energetik und Materialforschung, Berlin (Germany)); Alonso-Vante, N. (Hahn-Meitner-Inst., Abt. Solare Energetik und Materialforschung, Berlin (Germany)); Bueker, K. (Hahn-Meitner-Inst., Abt. Solare Energetik und Materialforschung, Berlin (Germany)); Bronold, M. (Hahn-Meitner-Inst., Abt. Solare Energetik und Materialforschung, Berlin (Germany)); Hoepfner, C. (Hahn-Meitner-Inst., Abt. Solare Energetik und Materialforschung, Berlin (Germany)); Tributsch, H. (Hahn-Meitner-Inst., Abt. Solare Energetik und Materialforschung, Berlin (Germany))

    1993-05-01

    Pyrite (E[sub g] = 0.95 eV) is being developed as a solar energy material due to its environmental compatibility and its very high light absorption coefficient. A compilation of material, electronic and interfacial chemical properties is presented, which is considered relevant for quantum energy conversion. In spite of intricate problems existing within material chemistry, high quantum efficiencies for photocurrent generation (> 90%) and high photovoltages ([approx] 500 mV) have been observed with single crystal electrodes and thin layers respectively. The most interesting aspect of this study is the use of pyrite as an ultrathin (10-20 nm) layer sandwiched between large gap p-type and n-type materials in a p-i-n like structure. Such a system, in which the pyrite layer only acts as photon absorber and mediates injection of excited electrons can be defined as sensitization solar cell. The peculiar electron transfer properties of pyrite interfaces, facilitating interfacial coordination chemical pathways, may turn out to be very helpful. Significant research challenges are discussed in the hope of attracting interest in the development of solar cells from this abundant material. (orig.)

  15. Diffusion coefficients of tracers in glassy polymer systems prepared by gamma radiolysis

    International Nuclear Information System (INIS)

    Tonge, M.P.; Gilbert, R.G.

    1996-01-01

    Diffusion-controlled reactions are common in free radical polymerisation reactions, especially in glassy polymer matrices. Such reactions commonly have an important influence on the polymerisation process and final polymer properties. For example, the dominant growth-stopping event (bimolecular termination) is generally diffusion-controlled. In glassy polymer systems, where molecular mobility is very low, the chain growth mechanism (propagation) may become diffusion-controlled. At present, the mechanism for propagation in glassy polymers is poorly understood, but it is expected by the Smoluchowski expression applied to propagation to depend strongly on the diffusion coefficient of monomer. The objective of this study is to measure reliable diffusion coefficients of small tracer molecules in glassy polymers, and compare these with propagation rate coefficients in similar systems, by the prediction above. Samples were initially prepared in a sealed sampled cell containing monomer, inert diluent, and tracer dye. After irradiation for several days, complete conversion of monomer to polymer can be obtained. The diffusion coefficients for two tracer dyes have been measured as a function of weight fraction polymer glassy poly(methyl methacrylate) samples

  16. Gas-liquid mass transfer coefficient of methane in bubble column reactor

    International Nuclear Information System (INIS)

    Lee, Jaewon; Ha, Kyoung-Su; Lee, Jinwon; Kim, Choongik; Yasin, Muhammad; Park, Shinyoung; Chang, In Seop; Lee, Eun Yeol

    2015-01-01

    Biological conversion of methane gas has been attracting considerable recent interest. However, methanotropic bioreactor is limited by low solubility of methane gas in aqueous solution. Although a large mass transfer coefficient of methane in water could possibly overcome this limitation, no dissolved methane probe in aqueous environment is commercially available. We have developed a reactor enabling the measurement of aqueous phase methane concentration and mass transfer coefficient (k L a). The feasibility of the new reactor was demonstrated by measuring k L a values as a function of spinning rate of impeller and flow rate of methane gas. Especially, at spinning rate of 300 rpm and flow rate of 3.0 L/min, a large k L a value of 102.9 h -1 was obtained

  17. Logiques de conversion identitaire dans l’exercice du métier Logics of Identity Conversion in Exercising one’s Profession. An Incursion into the World of Professional Handball

    Directory of Open Access Journals (Sweden)

    Christophe Mauny

    2011-02-01

    Full Text Available Le regard médiatique semble distiller une perception homogène voire standardisée du jeu sportif collectif. Cependant, derrière cette forme apparemment uniforme du jeu, s’entrevoit une diversité des regards de laquelle découle une pluralité de manières d’exprimer verbalement et corporellement le jeu sportif. En investissant le milieu du handball professionnel, notre travail méthodologique, de type herméneutique, tente d’accéder au sens que donnent les acteurs à leur pratique de prédilection au travers de leurs discours et de leurs comportements. Les résultats montrent que s’opère un véritable processus de conversion dans l’exercice du métier confrontant chacun au problème de sa propre identité professionnelle. Être joueur de handball de haut niveau, être joueur professionnel et être joueur expert d’une pratique sportive, ces trois postures se conjuguent et se situent au cœur de la définition identitaire du sportif.Media attention seems to distil a homogeneous or even standardized image of team sports. However, behind the apparent uniformity of sports, we glimpse a variety of images/portraits, from which flow many ways of verbally and corporally expressing team sports. In delving into the milieu of professional handball, our methodological work, of a hermeneutical type, tries to reach the meaning the actors give to their practice of predilection through their speech and their behaviours. The results show that a veritable process of conversion takes place in practicing the sport, confronting each of them with the problem of his own professional identity. Being a high level handball player, being a professional player and being an expert sports player, these three combined postures are at the heart of the athlete’s identity definition.

  18. Self-broadening coefficients and positions of acetylene around 1.533 μm studied by high-resolution diode laser absorption spectrometry

    International Nuclear Information System (INIS)

    Li Jingsong; Durry, Georges; Cousin, Julien; Joly, Lilian; Parvitte, Bertrand; Zeninari, Virginie

    2010-01-01

    The self-broadening coefficients of acetylene at room temperature have been measured for 10 lines in the P branch of the ν 1 +ν 3 (Σ u + )-0(Σ g + ) bands of 12 C 2 H 2 and 13 C 12 CH 2 near 1.533 μm, using a high resolution tunable diode laser spectrometer developed for the Martian space mission PHOBOS-Grunt. The collisional widths are obtained by fitting each recorded line with the Voigt profile as well as the Rautian profile accounting for the collisional Dicke narrowing effect. The standard Voigt model provides slightly smaller broadening coefficients than the Rautian model. Our data are thoroughly compared to the main atmospheric molecule database HITRAN and previous values in various bands of acetylene. Moreover, it is worth noting that a large number of new transitions not listed in the latest HITRAN08 were measured and identified for the first time.

  19. A comparison of two indices for the intraclass correlation coefficient.

    Science.gov (United States)

    Shieh, Gwowen

    2012-12-01

    In the present study, we examined the behavior of two indices for measuring the intraclass correlation in the one-way random effects model: the prevailing ICC(1) (Fisher, 1938) and the corrected eta-squared (Bliese & Halverson, 1998). These two procedures differ both in their methods of estimating the variance components that define the intraclass correlation coefficient and in their performance of bias and mean squared error in the estimation of the intraclass correlation coefficient. In contrast with the natural unbiased principle used to construct ICC(1), in the present study it was analytically shown that the corrected eta-squared estimator is identical to the maximum likelihood estimator and the pairwise estimator under equal group sizes. Moreover, the empirical results obtained from the present Monte Carlo simulation study across various group structures revealed the mutual dominance relationship between their truncated versions for negative values. The corrected eta-squared estimator performs better than the ICC(1) estimator when the underlying population intraclass correlation coefficient is small. Conversely, ICC(1) has a clear advantage over the corrected eta-squared for medium and large magnitudes of population intraclass correlation coefficient. The conceptual description and numerical investigation provide guidelines to help researchers choose between the two indices for more accurate reliability analysis in multilevel research.

  20. Conversion between Addenbrooke's Cognitive Examination III and Mini-Mental State Examination.

    Science.gov (United States)

    Matías-Guiu, Jordi A; Pytel, Vanesa; Cortés-Martínez, Ana; Valles-Salgado, María; Rognoni, Teresa; Moreno-Ramos, Teresa; Matías-Guiu, Jorge

    2017-12-10

    We aim to provide a conversion between Addenbrooke's Cognitive Examination III (ACE-III) and Mini-Mental State Examination (MMSE) scores, to predict the MMSE result based on ACE-III, thus avoiding the need for both tests, and improving their comparability. Equipercentile equating method was used to elaborate a conversion table using a group of 400 participants comprising healthy controls and Alzheimer's disease (AD) patients. Then, reliability was assessed in a group of 100 healthy controls and patients with AD, 52 with primary progressive aphasia and 22 with behavioral variant frontotemporal dementia. The conversion table between ACE-III and MMSE denoted a high reliability, with intra-class correlation coefficients of 0.940, 0.922, and 0.902 in the groups of healthy controls and AD, behavioral variant frontotemporal dementia, and primary progressive aphasia, respectively. Our conversion table between ACE-III and MMSE suggests that MMSE may be estimated based on the ACE-III score, which could be useful for clinical and research purposes.

  1. Calculation of conversion coefficients of dose of a computational anthropomorphic simulator sit exposed to a plane source; Calculo de coeficientes de conversao de dose de um simulador antropomorfico computacional sentado exposto a uma fonte plana

    Energy Technology Data Exchange (ETDEWEB)

    Santos, William S.; Carvalho Junior, Alberico B. de; Pereira, Ariana J.S.; Santos, Marcos S.; Maia, Ana F., E-mail: williathan@yahoo.com.b, E-mail: ablohem@gmail.co, E-mail: ariana-jsp@hotmail.co, E-mail: m_souzasantos@hotmail.co, E-mail: afmaia@ufs.b [Universidade Federal de Sergipe (UFS), Aracaju, SE (Brazil)

    2011-10-26

    In this paper conversion coefficients (CCs) of equivalent dose and effective in terms of kerma in the air were calculated suggested by the ICRP 74. These dose coefficients were calculated considering a plane radiation source and monoenergetic for a spectrum of energy varying from 10 keV to 2 MeV. The CCs were obtained for four geometries of irradiation, anterior-posterior, posterior-anterior, lateral right side and lateral left side. It was used the radiation transport code Visual Monte Carlo (VMC), and a anthropomorphic simulator of sit female voxel. The observed differences in the found values for the CCs at the four irradiation sceneries are direct results of the body organs disposition, and the distance of these organs to the irradiation source. The obtained CCs will be used for estimative more precise of dose in situations that the exposed individual be sit, as the normally the CCs available in the literature were calculated by using simulators always lying or on their feet

  2. U.S. Domestic Reactor Conversion Programs

    International Nuclear Information System (INIS)

    Woolstenhulme, Eric

    2008-01-01

    The Conversion Projects Include: the revision of the facilities safety basis documents and supporting analysis, the fabrication of new LEU fuel, the change-out of the reactor core, and the removal of the used HEU fuel (by INL University Fuels Program or DOE-NE). The major entities involved are: the U.S. Nuclear Regulatory Commission, the University reactor department, the fuel and hardware fabricators, the Spent fuel receipt facilities, the Spent fuel shipping services, and the U.S. Department of Energy and their subcontractors. Three major Reactor Conversion Program milestones have been accomplished since 2006: the conversion of the TRIGA reactor at Texas A and M University Nuclear Science Center, the conversion of the University of Florida Training Reactor, and the conversion of the Purdue University Reactor. Four Reactor Conversion Program milestones yet to be accomplished in 2008 and 2009: the Washington State University Nuclear Radiation Center reactor, the Oregon State University TRIGA Reactor, the University of Wisconsin Nuclear Reactor, and the Neutron Radiography Reactor Facility. NNSA is committed to doing things cheaper, better, smarter, safer through a 'Lessons Learned' process. The conversion team assessed each major activity grouping: Project Initiation, Conversion Proposal Development, Fuel Fabrication and Hardware, Core Conversion, and Spent Nuclear Fuel Removal. Issues were identified and recommendations were given

  3. Molecular extinction coefficients of lead sulfide and polymerized diaminobenzidine as final reaction products of histochemical phosphatase reactions

    NARCIS (Netherlands)

    van Noorden, C. J.; Jonges, G. N.

    1992-01-01

    Molar extinction coefficients of precipitated lead sulfide (PbS) and polymerized diaminobenzidine (polyDAB) have been determined at wavelengths of 450 nm and 480 nm, respectively, for quantitative histochemical analysis of phosphatase reactions. These values are essential for the conversion of

  4. Monitoring device for local power peaking coefficients

    International Nuclear Information System (INIS)

    Mihashi, Ishi

    1987-01-01

    Purpose: To determine and monitor the local power peaking coefficients by a method not depending on the combination of fuel types. Constitution: Representative values for the local power distribution can be obtained by determining corresponding burn-up degrees based on the burn-up degree of each of fuel assembly segments obtained in a power distribution monitor and by the interpolation and extrapolation of void coefficients. The typical values are multiplied with compensation coefficients for the control rod effect and coefficients for compensating the effect of adjacent fuel assemblies in a calculation device to obtain typical values for the present local power distribution compensated with all of the effects. Further, the calculation device compares them with typical values of the present local power distribution to obtain an aimed local power peaking coefficient as the maximum value thereof. According to the present invention, since the local power peaking coefficients can be determined not depending on the combination of the kind of fuels, if the combination of fuel assemblies is increased upon fuel change, the amount of operation therefor is not increased. (Kamimura, M.)

  5. Flexible Conversion Ratio Fast Reactor Systems Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Neil Todreas; Pavel Hejzlar

    2008-06-30

    Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores reated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcme the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better themal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor.

  6. Flexible Conversion Ratio Fast Reactor Systems Evaluation

    International Nuclear Information System (INIS)

    Neil Todreas; Pavel Hejzlar

    2008-01-01

    Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores treated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcome the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better thermal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor

  7. Conversion from tacrolimus-mycophenolate mofetil to tacrolimus-mTOR immunosuppression after kidney-pancreas transplantation reduces the incidence of both BK and CMV viremia.

    Science.gov (United States)

    Knight, Richard J; Graviss, Edward A; Nguyen, Duc T; Kuten, Samantha A; Patel, Samir J; Gaber, Lillian; Gaber, A Osama

    2018-04-19

    We sought to determine whether conversion from tacrolimus/mycophenolate mofetil (TAC-MMF) into tacrolimus/mTOR inhibitor (TAC-mTOR) immunosuppression would reduce the incidences of BK and CMV viremia after kidney/pancreas (KP) transplantation. In this single-center review, the TAC-mTOR cohort (n = 39) was converted at 1 month post-transplant to an mTOR inhibitor and reduced-dose tacrolimus. Outcomes were compared to a cohort of KP recipients (n = 40) maintained on TAC-MMF. At 3 years post-transplant, KP survivals and incidences of kidney/pancreas rejection were equivalent between mTOR and MMF-treated cohorts. (P = ns). BK viremia-free survival was better for the mTOR vs MMF-treated group (P = .004). In multivariate analysis, MMF vs mTOR immunosuppression was an independent risk factor for BK viremia (hazard ratio 12.27, P = .02). Similarly, mTOR-treated recipients displayed better CMV infection-free survival compared to the MMF-treated cohort (P = .01). MMF vs mTOR immunosuppression (hazard ratio 18.77, P = .001) and older recipient age (hazard ratio 1.13 per year, P = .006) were independent risk factors for CMV viremia. Mean estimated GFR and HgbA1c levels were equivalent between groups at 1, 2, and 3 years post-transplantation. Conversion from TAC/MMF into TAC/mTOR immunosuppression after KP transplantation reduced the incidences of BK and CMV viremia with an equivalent risk of acute rejection and similar renal/pancreas function. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. High-Order Model and Dynamic Filtering for Frame Rate Up-Conversion.

    Science.gov (United States)

    Bao, Wenbo; Zhang, Xiaoyun; Chen, Li; Ding, Lianghui; Gao, Zhiyong

    2018-08-01

    This paper proposes a novel frame rate up-conversion method through high-order model and dynamic filtering (HOMDF) for video pixels. Unlike the constant brightness and linear motion assumptions in traditional methods, the intensity and position of the video pixels are both modeled with high-order polynomials in terms of time. Then, the key problem of our method is to estimate the polynomial coefficients that represent the pixel's intensity variation, velocity, and acceleration. We propose to solve it with two energy objectives: one minimizes the auto-regressive prediction error of intensity variation by its past samples, and the other minimizes video frame's reconstruction error along the motion trajectory. To efficiently address the optimization problem for these coefficients, we propose the dynamic filtering solution inspired by video's temporal coherence. The optimal estimation of these coefficients is reformulated into a dynamic fusion of the prior estimate from pixel's temporal predecessor and the maximum likelihood estimate from current new observation. Finally, frame rate up-conversion is implemented using motion-compensated interpolation by pixel-wise intensity variation and motion trajectory. Benefited from the advanced model and dynamic filtering, the interpolated frame has much better visual quality. Extensive experiments on the natural and synthesized videos demonstrate the superiority of HOMDF over the state-of-the-art methods in both subjective and objective comparisons.

  9. Calibration coefficient of the SSNTD and equilibrium factor for radon

    International Nuclear Information System (INIS)

    Planinic, J.; Vukovic, B.

    1993-01-01

    Disintegration, ventilation and deposition were considered as removal processes of the radon and its short-lived daughters in air and respective concentration equations were applied. Calibration coefficient (K F ) of the solid state nuclear track detector (SSNTD) LR-115 for radon and the equilibrium factor (F) were related to track densities of the bare detector (D) and the filtered one (D o ). A useful relationship between K F , F and detector sensitivity coefficient (k) was derived. Using the calibrated value k=3.29 * 10 -3 m, the exposed detectors gave the average values of the equilibrium factor, calibration coefficient and indoor radon concentration of a single house living room in Osijek 0.46, 142.3 m -1 and 37.8 Bq m -3 , respectively. (author) 4 refs.; 1 fig

  10. Gas-liquid mass transfer coefficient of methane in bubble column reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jaewon; Ha, Kyoung-Su; Lee, Jinwon; Kim, Choongik [Sogang University, Seoul (Korea, Republic of); Yasin, Muhammad; Park, Shinyoung; Chang, In Seop [Gwangju Institute of Science and Technology (GIST), Gwangju (Korea, Republic of); Lee, Eun Yeol [Kyung Hee University, Yongin (Korea, Republic of)

    2015-06-15

    Biological conversion of methane gas has been attracting considerable recent interest. However, methanotropic bioreactor is limited by low solubility of methane gas in aqueous solution. Although a large mass transfer coefficient of methane in water could possibly overcome this limitation, no dissolved methane probe in aqueous environment is commercially available. We have developed a reactor enabling the measurement of aqueous phase methane concentration and mass transfer coefficient (k{sub L}a). The feasibility of the new reactor was demonstrated by measuring k{sub L}a values as a function of spinning rate of impeller and flow rate of methane gas. Especially, at spinning rate of 300 rpm and flow rate of 3.0 L/min, a large k{sub L}a value of 102.9 h{sup -1} was obtained.

  11. A Converse of Fermat's Little Theorem

    Science.gov (United States)

    Bruckman, P. S.

    2007-01-01

    As the name of the paper implies, a converse of Fermat's Little Theorem (FLT) is stated and proved. FLT states the following: if p is any prime, and x any integer, then x[superscript p] [equivalent to] x (mod p). There is already a well-known converse of FLT, known as Lehmer's Theorem, which is as follows: if x is an integer coprime with m, such…

  12. Coefficients calculations of conversion of cancer risk for occupational exposure using Monte Carlo simulations in cardiac procedures of interventionist radiology

    International Nuclear Information System (INIS)

    Santos, William S.; Neves, Lucio P.; Perini, Ana P.; Caldas, Linda V.E.; Maia, Ana F.

    2014-01-01

    Cardiac procedures are among the most common procedures in interventional radiology (IR), and can lead to high medical and occupational exposures, as in most cases are procedures complex and long lasting. In this work, conversion coefficients (CC) for the risk of cancer, normalized by kerma area product (KAP) to the patient, cardiologist and nurse were calculated using Monte Carlo simulation. The patient and the cardiologist were represented by anthropomorphic simulators MESH, and the nurse by anthropomorphic phantom FASH. Simulators were incorporated into the code of Monte Carlo MCNPX. Two scenarios were created: in the first (1), lead curtain and protective equipment suspended were not included, and in the second (2) these devices were inserted. The radiographic parameters employed in Monte Carlo simulations were: tube voltage of 60 kVp and 120 kVp; filtration of the beam and 3,5 mmAl beam area of 10 x 10 cm 2 . The average values of CCs to eight projections (in 10 -4 / Gy.cm 2 were 1,2 for the patient, 2,6E-03 (scenario 1) and 4,9E-04 (scenario 2) for cardiologist and 5,2E-04 (scenario 1) and 4,0E-04 (Scenario 2) to the nurse. The results show a significant reduction in CCs for professionals, when the lead curtain and protective equipment suspended are employed. The evaluation method used in this work can provide important information on the risk of cancer patient and professional, and thus improve the protection of workers in cardiac procedures of RI

  13. Spectral effects on some physical coefficients of x-Ray interaction with materials of low atomic number

    International Nuclear Information System (INIS)

    EL-Kazzaz, S.A.; Youssef, M.; EL-Hadad, S.; and EL-Nadi, L.M.

    1988-01-01

    X-ray spectra were measured before and after passing through some materials of medical importance applying X-ray diffraction. The mass absorption coefficients of these materials were determined at X-ray peak voltages 27, 30 and 42 kV-p making use the measured spectrum and also by using the direct beam absorption. It has been found that the mass absorption coefficients calculated from the X-ray spectral distribution analysis are in general lower than those obtained considering the direct beam method. From the study of the atomic number and energy dependence of the mass absorption coefficients it has been found that the dependence of the coefficients calculated from the spectral distribution is good agreement with the previously studied data for monoenergetic x-ray beam. Also the roentgen - to - Rad conversion factors were determined at the different used energies and materials. The value of the mass absorption coefficients calculated from the spectral distribution is recommended for use in dose calculation

  14. Material-specific Conversion Factors for Different Solid Phantoms Used in the Dosimetry of Different Brachytherapy Sources

    Directory of Open Access Journals (Sweden)

    Sedigheh Sina

    2015-07-01

    Full Text Available Introduction Based on Task Group No. 43 (TG-43U1 recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. The experimental determination of TG-43 parameters is usually performed in water-equivalent solid phantoms. The purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. Materials and Methods TG-43 parameters of low- and high-energy brachytherapy sources (i.e., Pd-103, I-125 and Cs-137 were obtained in different phantoms, using Monte Carlo simulations. The brachytherapy sources were simulated at the center of different phantoms including water, solid water, poly(methyl methacrylate, polystyrene and polyethylene. Dosimetric parameters such as dose rate constant, radial dose function and anisotropy function of each source were compared in different phantoms. Then, conversion factors were obtained to make phantom parameters equivalent to those of water. Results Polynomial coefficients of conversion factors were obtained for all sources to quantitatively compare g(r values in different phantom materials and the radial dose function in water. Conclusion Polynomial coefficients of conversion factors were obtained for all sources to quantitatively compare g(r values in different phantom materials and the radial dose function in water.

  15. Friction coefficient and limiter load test analysis by flexibility coefficient model of Hold-Down Spring of nuclear reactor vessel internals

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Linjun [Zhejiang Univ. of Technology, Hangzhou (China). College of Mechanical Engineering; Xue, Guohong; Zhang, Ming [Shanghai Nuclear Engineering Research and Design Institute, Shanghai (China)

    2017-11-15

    The friction force between the contact surfaces of a reactor internal hold-down spring (HDS) and core barrel flanges can directly influence the axial stiffness of an HDS. However, friction coefficient cannot be obtained through theoretical analysis. This study performs a mathematical deduction of the physical model of an HDS. Moreover, a mathematical model of axial load P, displacement δ, and flexibility coefficient is established, and a set of test apparatuses is designed to simulate the preloading process of the HDS. According to the experimental research and theoretical analysis, P-δ curves and the flexibility coefficient λ are obtained in the loading processes of the HDS. The friction coefficient f of the M1000 HDS is further calculated as 0.224. The displacement limit load value (4,638 kN) can be obtained through a displacement limit experiment. With the friction coefficient considered, the theoretical load is 4,271 kN, which is relatively close to the experimental result. Thus, the friction coefficient exerts an influence on the displacement limit load P. The friction coefficient should be considered in the design analysis for HDS.

  16. Friction coefficient and limiter load test analysis by flexibility coefficient model of Hold-Down Spring of nuclear reactor vessel internals

    International Nuclear Information System (INIS)

    Xie, Linjun

    2017-01-01

    The friction force between the contact surfaces of a reactor internal hold-down spring (HDS) and core barrel flanges can directly influence the axial stiffness of an HDS. However, friction coefficient cannot be obtained through theoretical analysis. This study performs a mathematical deduction of the physical model of an HDS. Moreover, a mathematical model of axial load P, displacement δ, and flexibility coefficient is established, and a set of test apparatuses is designed to simulate the preloading process of the HDS. According to the experimental research and theoretical analysis, P-δ curves and the flexibility coefficient λ are obtained in the loading processes of the HDS. The friction coefficient f of the M1000 HDS is further calculated as 0.224. The displacement limit load value (4,638 kN) can be obtained through a displacement limit experiment. With the friction coefficient considered, the theoretical load is 4,271 kN, which is relatively close to the experimental result. Thus, the friction coefficient exerts an influence on the displacement limit load P. The friction coefficient should be considered in the design analysis for HDS.

  17. On computing Laplace's coefficients and their derivatives.

    Science.gov (United States)

    Gerasimov, I. A.; Vinnikov, E. L.

    The algorithm of computing Laplace's coefficients and their derivatives is proposed with application of recurrent relations. The A.G.M.-method is used for the calculation of values L0(0), L0(1). The FORTRAN-program corresponding to the algorithm is given. The precision control was provided with numerical integrating by Simpsons method. The behavior of Laplace's coefficients and their third derivatives whith varying indices K, n for fixed values of the α-parameter is presented graphically.

  18. Internal conversion in highly stripped 83Kr ions

    International Nuclear Information System (INIS)

    Copnell, J.; Phillips, W.R.; Barnett, A.R.; Rehm, K.E.; Ahmad, I.; Gehring, J.; Glagola, B.G.; Kutschera, W.

    1995-01-01

    The total decay probabilities per unit time of the first excited 9.4-keV state in 83 Kr have been measured in ions of ionicity q from 28 to 32. Using a γ-decay probability per unit time of 0.255(2)x10 6 s -1 gives internal conversion coefficients of 14.6(11), 14.9(10), 14.1(9), 14.6(11), and 15.2(24) for q=28--32, respectively. These values are compared with theoretical predictions

  19. Critical electrode size in measurement of d33 coefficient of films via spatial distribution of piezoelectric displacement

    International Nuclear Information System (INIS)

    Wang Zhihong; Miao Jianmin

    2008-01-01

    Spatial distributions of piezoelectric displacement response across the top electrode have been used in this paper to measure the piezoelectric coefficient d 33 of films based on the converse piezoelectric effect. The technical details and features of a scanning laser Doppler vibrometer have been summarized and discussed for accurately obtaining the spatial displacement distributions. Three definitions, including the apparent, the effective and the constrained piezoelectric coefficient d 33 of films, have been clarified and used to better understand the fundamental phenomenon behind the measured displacement distributions. Finite element analysis reveals that both the apparent and the effective piezoelectric coefficients depend on the electrode radius of test capacitor as well as film thickness. However, there exists a critical electrode size for apparent piezoelectric coefficients and a critical test capacitor aspect ratio for effective piezoelectric coefficient. Beyond their respective critical values, both coefficients converge to the constrained piezoelectric coefficient irrespective of film thickness. The finding of the critical electric size makes it possible to consistently measure the constrained piezoelectric coefficient of films by using the spatial distributions of the piezoelectric displacement response and becomes the fundamental criterion of this measurement method

  20. Transport coefficients of black MQGP M3-branes

    International Nuclear Information System (INIS)

    Dhuria, Mansi; Misra, Aalok

    2015-01-01

    The Strominger-Yau-Zaslow (SYZ) mirror, in the 'delocalised limit' of Becker et al. (Nucl Phys B 702:207, 2004), of N D3-branes, M fractional D3-branes and N f flavour D7-branes wrapping a non-compact four-cycle in the presence of a black hole (BH) resulting in a non-Kahler resolved warped deformed conifold (NKRWDC) in Mia et al. (Nucl Phys B 839:187, 2010), was carried out in Dhuria and Misra (JHEP 1311:001, 2013) and resulted in black M3- branes. There are two parts in our paper. In the first we show that in the 'MQGP' limit discussed in Dhuria and Misra (JHEP 1311:001, 2013) a finite g s (and hence expected to be more relevant to QGP), finite g s M, N f , g s 2 MN f and very large g s N, and very small (g,M 2 )/(N), we have the following. (i) The uplift, if valid globally (like Dasgupta et al., Nucl Phys B 755:21, 2006) for fractional D3 branes in conifolds, asymptotically goes to M5-branes wrapping a two-cycle (homologously a (large) integer sum of two-spheres) in AdS 5 x M 6 . (ii) Assuming the deformation parameter to be larger than the resolution parameter, by estimating the five SU(3) structure torsion (τ) classes W 1,2,3,4,5 we verify that τ element of W 5 in the large-r limit, implying the NKRWDC reduces to a warped Kahler deformed conifold. (iii) The local T 3 of Dhuria and Misra (JHEP 1311:001, 2013) in the large-r limit satisfies the same conditions as the maximal T 2 -invariant special Lagrangian three-cycle of T*S 3 of Ionel and Min-OO (J Math 52(3), 2008), partly justifying use of SYZ-mirror symmetry in the ''delocalised limit'' of Becker et al. (Nucl Phys B 702:207, 2004) in Dhuria and Misra (JHEP 1311:001, 2013). In the second part of the paper, by either integrating out the angular coordinates of the non-compact four-cycle which a D7-brane wraps around, using the Ouyang embedding, in the DBI action of a D7-brane evaluated at infinite radial boundary, or by dimensionally reducing the 11-dimensional EH action to five (R 1,3 , r) dimensions and at

  1. Les contextes de la conversion à l’époque de la Réforme Contexts of conversion at time of Reform

    Directory of Open Access Journals (Sweden)

    Raymond Mentzer

    2010-03-01

    Full Text Available La conversion – le passage d’une affiliation religieuse à une autre - est un processus à la fois émouvant et ardu, même dans le cas où elle est estimée correcte du point de vue théologique avec la promesse du salut éternel. A l’époque de la Réforme, des hommes aussi bien que des femmes nous en ont donné la preuve. Pour examiner les questions autour du thème des contextes de la conversion et les protestants français, cet article divise le problème en trois parties. D'abord, il traite de la conversion au niveau de la communauté. Il s’agit des structures politiques, professionnelles et économiques qui favorisaient la conversion. Deuxièmement, la famille, qui conversions souvent les plus fortes et les plus durables. Enfin, et c'est le troisième point, tous protestants français ont été obligés eux-mêmes de se convertir au catholicisme en 1685 quand le Roi Soleil révoqua l’édit de Nantes. Comment ont-ils soumis à l’obligation de se convertir, et en même temps quelle stratégie ont-ils mis en place pour maintenir leur foi réformée, sauvegarder leurs familles, et d’essayer d’éviter la menace d’une monarchie catholique et ses alliés ecclésiastiques ?Conversion – the passage from one faith to another – was a challenging and painful process, even when it was deemed theologically correct and held the promise of eternal salvation. The men and women of the Reformation era offer poignant testimony. In its assessment investigation of the various question concerning conversion and Protestantism in early modern France, this article takes up three main themes. To begin, it examines conversion within the context of the community. What were the political, professional and economic structures that encouraged conversion? Secondly, the family, beyond any doubt a fundamental institution in pre-industrial society, was the site of the strongest and more enduring conversions. Finally, Protestants throughout France were

  2. An improved method for estimating the Ångström turbidity coefficient β in Central China during 1961–2010

    International Nuclear Information System (INIS)

    Wang, Lunche; Salazar, Germán Ariel; Gong, Wei; Peng, Simao; Zou, Ling; Lin, Aiwen

    2015-01-01

    The accurate determination of the atmospheric turbidity is of great importance for atmospheric environment, solar energy applications and climate change studies. Daily values of horizontal direct, diffuse and global solar radiation at Wuhan, Central China during 1961–2010 are used for estimating the monthly mean Ångström turbidity coefficient β. The YHM and YHM2 (Yang hybrid models) are first used to estimate the direct and diffuse components considering the transmittances of ozone, water vapor, gas mixture, aerosol and Rayleigh effect in the radiative transfer processes. An IMW (improved model for Wuhan) is also proposed by combining the format of YHM model with the corrected spectral terms of YHM2 model. Then, the β value can be estimated by varying the estimated direct irradiation until it matches the observation. The model performance is analyzed and compared and further validated by measured values using Sun photometer CE318. It is shown that the IMW model presents more accurate estimates than YHM and YHM2 ones; it is therefore a useful tool for studying the variability and evolution of atmospheric turbidity in other places around the world. - Highlights: • Global, direct and diffuse radiation at Wuhan during 1961–2010 is used. • An improved model is proposed to determine turbidity coefficient β. • The model results have been validated by field observations. • Long-term variations of turbidity coefficient at Wuhan are analyzed

  3. Hierarchically structured exergetic and exergoeconomic analysis and evaluation of energy conversion processes

    International Nuclear Information System (INIS)

    Hebecker, Dietrich; Bittrich, Petra; Riedl, Karsten

    2005-01-01

    Evaluation of the efficiency and economic benefit of energy conversion processes and technologies requires a scientifically based analysis. The hierarchically structured exergetic analysis provides a detailed characterization of complex technical systems. By defining corresponding evaluation coefficients, the exergetic efficiency can be assessed for units within the whole system. Based on this exergetic analysis, a thermoeconomic evaluation method is developed. A cost function is defined for all units, subsystems and the total plant, so that the cost flow in the system can be calculated. Three dimensionless coefficients, the Pauer factor, the loss coefficient and the cost factor, enable pinpointing cost intensive process units, allocating cost in cases of co-production and gaining insight for future design improvements. The methodology is demonstrated by a biomass gasification plant producing electricity, heat and cold

  4. Conversion factors for a mobile survey method by car in the Chernobyl area

    International Nuclear Information System (INIS)

    Sakamoto, R.; Saito, K.

    2003-01-01

    Conversion factors for the purpose of mobile survey by car in the Chernobyl area have been evaluated using simulation calculations. In the calculations, the width of road is assumed as being 4 m, 10 m and 20 m and the surrounding area is divided into ten zones contaminated homogeneously by 137 Cs with different depth profiles in the ground. The air kerma contribution from all zones to the road is simulated. A conversion factor is calculated by dividing the air kerma rate in typical land-use adjacent to the road by that on the road. Conversion factors in various land uses around the roads are examined. The calculated conversion factors agree with the conversion factors measured in the Chernobyl area within an accuracy of 20%. Further, basic data, needed for composing conversion factors appropriate to other contaminated regions with different depth distributions from the Chernobyl area, are also indicated. (author)

  5. Neural network based method for conversion of solar radiation data

    International Nuclear Information System (INIS)

    Celik, Ali N.; Muneer, Tariq

    2013-01-01

    Highlights: ► Generalized regression neural network is used to predict the solar radiation on tilted surfaces. ► The above network, amongst many such as multilayer perceptron, is the most successful one. ► The present neural network returns a relative mean absolute error value of 9.1%. ► The present model leads to a mean absolute error value of estimate of 14.9 Wh/m 2 . - Abstract: The receiving ends of the solar energy conversion systems that generate heat or electricity from radiation is usually tilted at an optimum angle to increase the solar incident on the surface. Solar irradiation data measured on horizontal surfaces is readily available for many locations where such solar energy conversion systems are installed. Various equations have been developed to convert solar irradiation data measured on horizontal surface to that on tilted one. These equations constitute the conventional approach. In this article, an alternative approach, generalized regression type of neural network, is used to predict the solar irradiation on tilted surfaces, using the minimum number of variables involved in the physical process, namely the global solar irradiation on horizontal surface, declination and hour angles. Artificial neural networks have been successfully used in recent years for optimization, prediction and modeling in energy systems as alternative to conventional modeling approaches. To show the merit of the presently developed neural network, the solar irradiation data predicted from the novel model was compared to that from the conventional approach (isotropic and anisotropic models), with strict reference to the irradiation data measured in the same location. The present neural network model was found to provide closer solar irradiation values to the measured than the conventional approach, with a mean absolute error value of 14.9 Wh/m 2 . The other statistical values of coefficient of determination and relative mean absolute error also indicate the

  6. Stress Optical Coefficient, Test Methodology, and Glass Standard Evaluation

    Science.gov (United States)

    2016-05-01

    ARL-TN-0756 ● MAY 2016 US Army Research Laboratory Stress Optical Coefficient, Test Methodology , and Glass Standard Evaluation...Stress Optical Coefficient, Test Methodology , and Glass Standard Evaluation by Clayton M Weiss Oak Ridge Institute for Science and Education...ORISE), Belcamp, MD Parimal J Patel Weapons and Materials Research Directorate, ARL Approved for public release; distribution is

  7. Electron excitation coefficients of neutral and ionic levels of krypton in Townsend discharges

    International Nuclear Information System (INIS)

    Malovic, G.N.; Strinic, A.I.; Petrovic, Z.Lj.; Sadeghi, N.

    2006-01-01

    In this paper, we present experimental results for excitation coefficients of krypton atoms to several Kr and Kr + excited levels for E/N (electric field to gas particle number density ratio usually in units of Townsend, 1 Td = 10 -21 V m 2 ) values from 7 x 10 -20 V m 2 to above 1 x 10 -17 V m 2 . The data have been obtained in two different parallel plate self-sustained Townsend discharge drift tubes. The spatial distribution of the emission intensities were recorded and then normalized to give excitation coefficients at the anode, by using the electron flux at this point. The values of these coefficients are placed on an absolute scale by using a standard tungsten ribbon lamp calibrated against a primary blackbody radiation standard. The ionization rates at different E/N are obtained from the spatial emission profiles. The data for atomic krypton levels 2p 2 , 2p 3 , 2p 5 , 2p 6 , 2p 7 , 2p 8 , 3p 5 and 3p 6 (in Paschen notation) were converted to excitation coefficients by using quenching coefficients from the literature. The emission coefficients of eight 4s 2 4p 4 ( 3 P)5p levels of Kr + have also been measured for E/N values from about 1 x 10 -18 V m 2 up to nearly 8 x 10 -18 V m 2

  8. Towards spontaneous parametric down-conversion at low temperatures

    Directory of Open Access Journals (Sweden)

    Akatiev Dmitrii

    2017-01-01

    Full Text Available The possibility of observing spontaneous parametric down-conversion in doped nonlinear crystals at low temperatures, which would be useful for combining heralded single-photon sources and quantum memories, is studied theoretically. The ordinary refractive index of a lithium niobate crystal doped with magnesium oxide LiNbO3:MgO is measured at liquid nitrogen and helium temperatures. On the basis of the experimental data, the coefficients of the Sellmeier equation are determined for the temperatures from 5 to 300 K. In addition, a poling period of the nonlinear crystal has been calculated for observing type-0 spontaneous parametric down-conversion (ooo-synchronism at the liquid helium temperature under pumping at the wavelength of λp = 532 nm and emission of the signal field at the wavelength of λs = 794 nm, which corresponds to the resonant absorption line of Tm3+ doped ions.

  9. Carbon balances during land conversion in early bioenergy systems

    Science.gov (United States)

    Zenone, T.; Chen, J.; Gelfand, I.; Robertson, G. P.; Hamilton, S. K.

    2012-12-01

    In this study, we established a field experiment and deployed seven eddy-covariance towers to quantify the roles of land use change and the subsequent carbon (C) balances of three different bioenergy systems (corn, switchgrass, and mixed prairie species) that were developed from two historical land use types: monocultural grasslands dominated by smooth brome (Bromus inermis Leyss) and lands in the Conservation Reserve Program (CRP). Three CRP fields and three cropland fields were converted to soybean in 2009 (conversion year) before establishing the cellulosic biofuel cropping systems in 2010 (establishment year). A CRP perennial grassland site was kept undisturbed as a reference. Conversion of CRP to soybean induced net C emissions during the conversion year (134 -262 g C m-2 yr-1), while in the same year the net C balance at the CRP grassland reference was -35 g C m-2 yr-1 (i.e., net C sequestration). The establishment of switchgrass and mixed prairie induced a cumulative C balance of -113 g C m-2 (switchgrass from CRP), 250 g C m-2 (switchgrass from cropland), 706 g C m-2 (mixed prairie from CRP), and 59 g C m-2 (mixed prairie from cropland) over the three-year study period. The cumulative three-year C balance of corn converted from CRP and from cropland was -151 g C m-2 and -183 g C m-2, respectively. Eddy flux measurements during cellulosic biofuel crop establishment reveal annual changes in C balance that cannot be detected using conventional mass balance approaches. When end-use of harvested biomass was considered, the C balances for all studied systems, except the reference site, exhibited large C emissions ranging from 150 to 990 g C m-2 over the three-year conversion phase.

  10. A novel on-chip high to low voltage power conversion circuit

    International Nuclear Information System (INIS)

    Wang Hui; Wang Songlin; Mou Zaixin; Guo Baolong; Lai Xinquan; Ye Qiang; Li Xianrui

    2009-01-01

    A novel power supply transform technique for high voltage IC based on the TSMC 0.6 μm BCD process is achieved. An adjustable bandgap voltage reference is presented which is different from the traditional power supply transform technique. It can be used as an internal power supply for high voltage IC by using the push-pull output stage to enhance its load capability. High-order temperature compensated circuit is designed to ensure the precision of the reference. Only 0.01 mm 2 area is occupied using this novel power supply technique. Compared with traditional technique, 50% of the area is saved, 40% quiescent power loss is decreased, and the temperature coefficient of the reference is only 4.48 ppm/deg. C. Compared with the traditional LDO (low dropout) regulator, this power conversion architecture does not need external output capacitance and decreases the chip-pin and external components, so the PCB area and design cost are also decreased. The testing results show that this circuit works well.

  11. Local diffusion coefficient determination: Mediterranean Sea experiments

    International Nuclear Information System (INIS)

    Bacciola, D.; Borghini, M.; Cannarsa, S.

    1993-10-01

    The Mediterranean is a semi/enclosed basin characterized by the presence of channels and straits influencing the circulation, temperature and salinity fields. The tides generally have amplitudes of the order of 10 cm and velocities of few cm/s. Conversely, the wind forced circulation is very strong and can assume velocity values of 1 m/s at the sea surface. The temperature and salinity fields have a high temporal and spatial variability, because of many mixing processes existing in the sea. For example, the waters coming from the Provencal basin meet those waters coming from the Tyrrhenian Sea in the eastern Ligurian Sea, creating meanders and eddies. Local runoff influences significantly the coastal circulation. This paper describes diffusion experiments carried out in this complex environment. The experimental apparatus for the detection of the fluorescine released at sea was composed by two Turner mod. 450 fluorometres. During the experiments, temperature and salinity vertical profiles were measured by using a CTD; meteorological data were acquired on a dinghy. The positioning was obtained by means of a Motorola system, having a precision of about 1 meter. The experiments were carried out under different stratification and wind conditions. From data analysis it was found that the horizontal diffusion coefficient does not depend on time or boundary conditions. The role of stratification is important with regard to vertical displacement of the dye. However, its role with regard to vertical diffusion cannot be assessed with the actual experimental apparatus

  12. IRT - Sofia conversion feasibility study experience 2002-2009

    Energy Technology Data Exchange (ETDEWEB)

    Belousov, S.I.; Apostolov, T.G. [Institute for Nuclear Research and Nuclear Energy of Bulgarian Academy of Science, Tsarigradsko 72, 1784 Sofia (Bulgaria)

    2010-07-01

    A joint conversion feasibility study concerning the IRT - Sofia research reactor between INRNE and the RERTR Program at ANL was initiated in 2002. The initial steps studies (up to 2006) were mainly focused on neutronics properties significant for reactor application and safety analyses. Thermal hydraulic, accident analyses as well as additional neutronics study required were performed after that (up to 2010). The obtained results show that the IRT-4M LEU fuel assemblies (19.75% {sup 235}U enrichment) are appropriate for IRT-Sofia conversion (IRT-Sofia was initially designed for the IRT-2M HEU fuel assemblies with 36% {sup 235}U enrichment). The results obtained in the frames of the joint study show that the IRT-Sofia operation even with usage of only one pump in the primary circuit meets all safety requirements at power level up to 1000 kW and that safety is maintained for accident transients. Presented results of analyses (neutronics, thermal hydraulic, and accident) and accumulated experience for the IRT-Sofia will be useful for other research reactors where conversion from IRT-2M (HEU) to IRT-4M (LEU) fuel is underway and/or foreseen. (authors)

  13. Friction Experiments for Dynamical Coefficient Measurement

    Directory of Open Access Journals (Sweden)

    J. J. Arnoux

    2011-01-01

    Full Text Available An experimental study, including three experimental devices, is presented in order to investigate dry friction phenomena in a wide range of sliding speeds for the steel on steel contact. A ballistic setup, with an air gun launch, allows to estimate the friction coefficient between 20 m/s and 80 m/s. Tests are completed by an adaptation of the sensor on a hydraulic tensile machine (0.01 m/s to 3 m/s and a pin-on-disk tribometer mounted on a CNC lathe (1 to 30 m/s. The interactions at the asperity scale are characterized by a white light interferometer surface analysis.

  14. Wind turbine power coefficient estimation by soft computing methodologies: Comparative study

    International Nuclear Information System (INIS)

    Shamshirband, Shahaboddin; Petković, Dalibor; Saboohi, Hadi; Anuar, Nor Badrul; Inayat, Irum; Akib, Shatirah; Ćojbašić, Žarko; Nikolić, Vlastimir; Mat Kiah, Miss Laiha; Gani, Abdullah

    2014-01-01

    Highlights: • Variable speed operation of wind turbine to increase power generation. • Changeability and fluctuation of wind has to be accounted. • To build an effective prediction model of wind turbine power coefficient. • The impact of the variation in the blade pitch angle and tip speed ratio. • Support vector regression methodology application as predictive methodology. - Abstract: Wind energy has become a large contender of traditional fossil fuel energy, particularly with the successful operation of multi-megawatt sized wind turbines. However, reasonable wind speed is not adequately sustainable everywhere to build an economical wind farm. In wind energy conversion systems, one of the operational problems is the changeability and fluctuation of wind. In most cases, wind speed can vacillate rapidly. Hence, quality of produced energy becomes an important problem in wind energy conversion plants. Several control techniques have been applied to improve the quality of power generated from wind turbines. In this study, the polynomial and radial basis function (RBF) are applied as the kernel function of support vector regression (SVR) to estimate optimal power coefficient value of the wind turbines. Instead of minimizing the observed training error, SVR p oly and SVR r bf attempt to minimize the generalization error bound so as to achieve generalized performance. The experimental results show that an improvement in predictive accuracy and capability of generalization can be achieved by the SVR approach in compare to other soft computing methodologies

  15. Effect of Non-Equilibrium Condensation on Force Coefficients in Transonic Airfoil Flow

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Min; Kang, Hui Bo; Kwon, Young Doo; Kwon, Soon Bum [Kyungpook National Univeristy, Daegu (Korea, Republic of); Jeon, Heung Kyun [Daegu Health College, Daegu (Korea, Republic of)

    2014-12-15

    The present study investigated the effects of non-equilibrium condensation with the angle of attack on the coefficients of pressure, lift, and drag in the transonic 2-D flow of NACA0012 by numerical analysis of the total variation diminishing (TVD) scheme. At T{sub 0}=298 K and α=3°, the lift coefficients for M{sub ∞}=0.78 and 0.81 decreased monotonically with increasing Φ{sub 0}. In contrast, for M{sub ∞} corresponding to the Mach number of the force break, CL increased with Φ{sub 0}. For α=3° and Φ{sub 0}=0%, CD increased markedly as M{sub ∞} increased. However, at Φ{sub 0}=60% and α=3°, which corresponded to the case of the condensation having a large influence, CD increased slightly as M{sub ∞} increased. The decrease in profile drag by non-equilibrium condensation grew as the angle of attack and stagnation relative humidity increased for the same free stream transonic Mach number. At Φ{sub 0}=0%, the coefficient of the wave drag increased with the attack angle and free stream Mach number. When Φ{sub 0}>50%, the coefficient of the wave drag decreased as α and M{sub ∞} increased. Lowering Φ{sub 0} and increasing M{sub ∞} increased the maximum Mach number.

  16. FIELD-SCALE EFFECTIVE MATRIX DIFFUSION COEFFICIENT FOR FRACTURED ROCK: RESULTS FROM LITERATURE SURVEY

    International Nuclear Information System (INIS)

    Zhou, Q.; Hui-Hai Liu; Molz, F.J.; Zhang, Y.; Bodvarsson, G.S.

    2005-01-01

    Matrix diffusion is an important mechanism for solute transport in fractured rock. We recently conducted a literature survey on the effective matrix diffusion coefficient, D m e , a key parameter for describing matrix diffusion processes at the field scale. Forty field tracer tests at 15 fractured geologic sites were surveyed and selected for the study, based on data availability and quality. Field-scale D m e values were calculated, either directly using data reported in the literature or by reanalyzing the corresponding field tracer tests. Surveyed data indicate that the effective-matrix-diffusion-coefficient factor F D (defined as the ratio of D m e to the lab-scale matrix diffusion coefficient [D m ] of the same tracer) is generally larger than one, indicating that the effective matrix diffusion coefficient in the field is comparatively larger than the matrix diffusion coefficient at the rock-core scale. This larger value can be attributed to the many mass-transfer processes at different scales in naturally heterogeneous, fractured rock systems. Furthermore, we observed a moderate trend toward systematic increase in the F D value with observation scale, indicating that the effective matrix diffusion coefficient is likely to be statistically scale dependent. The F D value ranges from 1 to 10,000 for observation scales from 5 to 2,000 m. At a given scale, the F D value varies by two orders of magnitude, reflecting the influence of differing degrees of fractured rock heterogeneity at different sites. In addition, the surveyed data indicate that field-scale longitudinal dispersivity generally increases with observation scale, which is consistent with previous studies. The scale-dependent field-scale matrix diffusion coefficient (and dispersivity) may have significant implications for assessing long-term, large-scale radionuclide and contaminant transport events in fractured rock, both for nuclear waste disposal and contaminant remediation

  17. La conversion de Paul, regards croisés Paul’s conversion. Cross perspectives

    Directory of Open Access Journals (Sweden)

    Elian Cuvillier

    2009-09-01

    Full Text Available Au plan historique, les traditions relatives à la conversion de Paul, chutant de son cheval sur le chemin de Damas, confrontent l’exégète à trois problèmes importants : y avait-il un cheval, cela se passait-il sur le chemin de Damas et était-ce bien une conversion ? Entendues avec l’humour et la distance critique nécessaires, ces trois questions constituent les trois chapitres de cet article. Le premier « Y avait-il un cheval ? » s’intéresse à l’histoire de la réception de l’épisode de la conversion de Paul, en particulier dans la peinture et la littérature. Le second « Cela se passait-il sur le chemin de Damas ? » est consacrée au récit que l’auteur du livre des Actes propose de la conversion de Paul, récit qui constitue, bien souvent, la porte d’entrée exclusive pour aborder le thème. Le troisième « Etait-ce bien une conversion ? » analyse les témoignages de l’apôtre lui-même à travers deux passages clés de ses épîtres authentiques.Historically speaking, the traditions concerning the conversion of Paul, falling from his horse on the road to Damascus, confront the exegete with three important problems : was there a horse, did it happen on the road to Damacus and was it really a conversion ? These three questions, considered with humor and critical distance, constitute the three sections of this article. The first part « Was there a horse ? » considers the history of the reception of the episode of the conversion of Paul, particularly in art and literature. The second one « Did it happen on the road to Damascus ? » is devoted to the story of the conversion of Paul proposed by the author of the book of Acts, which is very often the exclusive entrance to the discussion of this theme. The third section « Was it really a conversion ? » analyzes the account given by the apostle himself in two key passages of his authentic epistles.

  18. Generation of 1.3 μm and 1.5 μm high-energy Raman radiations in α-BaTeMo2O9 crystals

    Science.gov (United States)

    Liu, Shande; Zhang, Junjie; Gao, Zeliang; Wei, Lei; Zhang, Shaojun; He, Jingliang; Tao, Xutang

    2014-02-01

    The generations of high energy 2nd- and 3rd-order stimulated Raman scattering lasers based on the α-BaTeMo2O9 crystal were demonstrated for the first time. The Raman gain coefficient has been compared with that of the YVO4 crystal. A maximum total Stokes radiation energy of 27.3 mJ was obtained, containing 20.1 mJ 2nd-order Stokes energy at 1318 nm, together with 7.2 mJ 3rd-order Stokes energy at 1497 nm, giving an overall conversion efficiency of 35.9% and a slope efficiency of 54.5%. With an optical coating design, a total 3rd- and 4th-order Stokes energy of 16.5 mJ was generated. The maximum energy for 4th-order Stokes radiation at 1731 nm was 2 mJ. The pulse durations for the 2nd-, 3rd-, and 4th-order Stokes shift were 10 ns, 8.6 ns, and 5.2 ns, respectively. Our experimental results show that the α-BTM crystal is a promising Raman crystal for the generations of eye-safe radiations.

  19. Determination of ion diffusion coefficients by the electromigration method

    International Nuclear Information System (INIS)

    Bonchev, G.D.; Milanov, M.V.; Bozhikov, G.A.; Ivanov, P.I.; Priemyshev, A.N.; Maslov, O.D.; Dmitriev, S.N.

    2003-01-01

    An electrophoretic method for measuring ion diffusion coefficients in aqueous solutions is developed. The value of the diffusion coefficient can be determined from the linear relationship between the square standard deviation of the electrophoretic zone and the time from the start of the diffusion process. Using the device for horizontal zone electrophoresis in a free electrolyte, a series of diffusion experiments are performed with no-carrier-added radionuclides in microconcentrations (10 -9 - 10 -10 M). Diffusion coefficients of 111 In(III), 175 Hf(IV) and 237 Pu(VI) ions at 25 0 C are determined in nitric acid media. Simultaneous determination of the diffusion coefficient and electrophoretic mobility allows one to calculate the effective charge of the investigated ions in accordance with the Nernst-Einstein law

  20. Comparison of four large-eddy simulation research codes and effects of model coefficient and inflow turbulence in actuator-line-based wind turbine modeling

    DEFF Research Database (Denmark)

    Martínez-Tossas, Luis A.; Churchfield, Matthew J.; Yilmaz, Ali Emre

    2018-01-01

    to match closely for all codes. The value of the Smagorinsky coefficient in the subgrid-scale turbulence model is shown to have a negligible effect on the time-averaged loads along the blades. Conversely, the breakdown location of the wake is strongly dependent on the Smagorinsky coefficient in uniform...... coefficient has a negligible effect on the wake profiles. It is concluded that for LES of wind turbines and wind farms using ALM, careful implementation and extensive cross-verification among codes can result in highly reproducible predictions. Moreover, the characteristics of the inflow turbulence appear...

  1. A technique for measuring dynamic friction coefficient under impact loading.

    Science.gov (United States)

    Lin, Y L; Qin, J G; Chen, R; Zhao, P D; Lu, F Y

    2014-09-01

    We develop a novel setup based on the split Hopkinson pressure bar technique to test the dynamic friction coefficient under impact loading. In the setup, the major improvement is that the end of the incident bar near the specimen is wedge-shaped, which results in a combined compressive and shear loading applied to the specimen. In fact, the shear loading is caused by the interfacial friction between specimen and bars. Therefore, when the two loading force histories are measured, the friction coefficient histories can be calculated without any assumptions and theoretical derivations. The geometry of the friction pairs is simple, and can be either cuboid or cylindrical. Regarding the measurements, two quartz transducers are used to directly record the force histories, and an optical apparatus is designed to test the interfacial slip movement. By using the setup, the dynamic friction coefficient of PTFE/aluminum 7075 friction pairs was tested. The time resolved dynamic friction coefficient and slip movement histories were achieved. The results show that the friction coefficient changes during the loading process, the average data of the relatively stable flat plateau section of the friction coefficient curves is 0.137, the maximum normal pressure is 52 MPa, the maximum relative slip velocity is 1.5 m/s, and the acceleration is 8400 m(2)/s. Furthermore, the friction test was simulated using an explicit FEM code LS-DYNA. The simulation results showed that the constant pressure and slip velocity can both be obtained with a wide flat plateau incident pulse. For some special friction pairs, normal pressure up to a few hundred MPa, interfacial slip velocities up to 10 m/s, and slip movement up to centimeter-level can be expected.

  2. Absolute and relative-rate measurement of the rate coefficient for reaction of perfluoro ethyl vinyl ether (C2F5OCF[double bond, length as m-dash]CF2) with OH.

    Science.gov (United States)

    Srinivasulu, G; Bunkan, A J C; Amedro, D; Crowley, J N

    2018-01-31

    The rate coefficient (k 1 ) for the reaction of OH radicals with perfluoro ethyl vinyl ether (PEVE, C 2 F 5 OCF[double bond, length as m-dash]CF 2 ) has been measured as a function of temperature (T = 207-300 K) using the technique of pulsed laser photolysis with detection of OH by laser-induced fluorescence (PLP-LIF) at pressures of 50 or 100 Torr N 2 bath gas. In addition, the rate coefficient was measured at 298 K and in one atmosphere of air by the relative-rate technique with loss of PEVE and reference reactant monitored in situ by IR absorption spectroscopy. The rate coefficient has a negative temperature dependence which can be parameterized as: k 1 (T) = 6.0 × 10 -13  exp[(480 ± 38/T)] cm 3 molecule -1 s -1 and a room temperature value of k 1 (298 K) = (3.0 ± 0.3) × 10 -12 cm 3 molecule -1 s -1 . Highly accurate rate coefficients from the PLP-LIF experiments were achieved by optical on-line measurements of PEVE and by performing the measurements at two different apparatuses. The large rate coefficient and the temperature dependence indicate that the reaction proceeds via OH addition to the C[double bond, length as m-dash]C double bond, the high pressure limit already being reached at 50 Torr N 2 . Based on the rate coefficient and average OH levels, the atmospheric lifetime of PEVE was estimated to be a few days.

  3. A new search for conversion of muonium to antimuonium

    International Nuclear Information System (INIS)

    Matthias, B.E.

    1991-10-01

    To search for conversion of muonium (M ≡ μ + e - ) to antimuonium (anti M ≡ μ - e + ) with very low background, a new signature was implemented that required the time-coincident detection of the decay e - (≤ 53 MeV) with the atomic e + (∼ 13 eV) from decay of an anti M atom. A 20 MeV/c μ + beam was stopped in a 9 mg/cm 2 SiO 2 powder target. Muonium, formed in the powder, diffused into a vacuum region at thermal velocities and was observed for a coincidence of anti M decay products. Any decay e - was charge and momentum analyzed in a dipole magnet and tracked by an array of MWPCs; any atomic e + was electrostatically collected, accelerated to 5.7 keV, and magnetically transported to a microchannel plate detector. To calibrate the signature, M was observed for the first time by coincidence of its decay e + and its atomic e - . A maximum likelihood analysis of the position distribution of decay origins finds no anti M events and less than 2 at 90% confidence. This places an upper limit on the conversion probability per atom of S anti M -7 (90% C.L.), which corresponds to an upper limit of G M anti M F (90% C.L.) on the effective coupling constant for a (V - A) conversion coupling. In a class of left-right symmetric models, the value of G M anti M may be in this range. 116 refs., 45 figs., 10 tabs

  4. Measuring device for the temperature coefficient of reactor moderators

    International Nuclear Information System (INIS)

    Nakano, Yuzo.

    1987-01-01

    Purpose: To rapidly determine by automatic calculation the temperature coefficient for moderators which has been determined so far by a log of manual processings. Constitution: Each of signals from a control rod position indicator, a reactor reactivity, instrument and moderator temperature meter are inputted, and each of the signals and designed valued for the doppler temperature coefficients are stored. Recurling calculation is conducted based on the reactivity and the moderator temperature at an interval where the temperature changes of the moderators are equalized at an identical control rod position, to determine isothermic coefficient. Then, the temperature coefficient for moderator are calculated from the isothermic coefficient and the doppler temperature coefficient. The relationship between the reactivity and the moderator temperature is plotted on a X-Y recorder. The stored signals and the calculated temperature coefficient for moderators are sequentially displayed and the results are printed out when the measurement is completed. According to the present device, since the real time processing is conducted, the processing time can be shortened remarkably. Accordingly, it is possible to save the man power for the test of the nuclear reactor and improve the reactor operation performance. (Kamimura, M.)

  5. External dose conversion factor from canal water

    International Nuclear Information System (INIS)

    Bhargava, Pradeep; Chitra, S.; Mhatre, Arti S.; Singh, Kapil Deo

    2016-01-01

    External dose needs to be estimated for the radioactivity discharged into the canal, as it constitutes one of the pathways of exposure to the public. Two activities are considered here: i) a walk along the bank of the canal ii) and the walk on the bridge. A concentration of 1 Bq/l is assumed here for the gross beta activity for the estimation of the dose conversion factor. A canal of width 14.39 m and the depth of 2.5 m is considered for this study. Length of the canal is taken to be infinite. Canal side wall is assumed to be the 25 cm thick concrete. Two points are selected, one on the bank, and the second on a bridge 1 m above the top surface of canal water. Dose Conversion factors for the person moving on the Bridge (at one meter above the water surface) and standing on bank of canal is estimated by using the QAD CG code for 137 Cs. Dose conversion factors for the location mentioned above are found to be 1.11E-10 Sv/hr/(Bq/l) and 1.55 E-11 Sv/hr/(Bq/l) for bridge and bank of canal respectively. (author)

  6. Comparison of conversion coefficients for equivalent dose in terms of air kerma for photons using a male adult voxel simulator in sitting and standing posture with geometry of irradiation antero-posterior

    International Nuclear Information System (INIS)

    Galeano, D.C.; Cavalcante, F.R.; Carvalho, A.B.; Hunt, J.

    2014-01-01

    The dose conversion coefficient (DCC) is important to quantify and assess effective doses associated with medical, professional and public exposures. The calculation of DCCs using anthropomorphic simulators and radiation transport codes is justified since in-vivo measurement of effective dose is extremely difficult and not practical for occupational dosimetry. DCCs have been published by the ICRP using simulators in a standing posture, which is not always applicable to all exposure scenarios, providing an inaccurate dose estimation. The aim of this work was to calculate DCCs for equivalent dose in terms of air kerma (H/Kair) using the Visual Monte Carlo (VMC) code and the VOXTISS8 adult male voxel simulator in sitting and standing postures. In both postures, the simulator was irradiated by a plane source of monoenergetic photons in antero-posterior (AP) geometry. The photon energy ranged from 15 keV to 2 MeV. The DCCs for both postures were compared and the DCCs for the standing simulator were higher. For certain organs, the difference of DCCs were more significant, as in gonads (48% higher), bladder (16% higher) and colon (11% higher). As these organs are positioned in the abdominal region, the posture of the anthropomorphic simulator modifies the form in which the radiation is transported and how the energy is deposited. It was also noted that the average percentage difference of conversion coefficients was 33% for the bone marrow, 11% for the skin, 13% for the bone surface and 31% for the muscle. For other organs, the percentage difference of the DCCs for both postures was not relevant (less than 5%) due to no anatomical changes in the organs of the head, chest and upper abdomen. We can conclude that is important to obtain DCCs using different postures from those present in the scientific literature. - Highlights: • Scenarios of external photon exposures were performed in VMC code. • The VOXTISS8 simulator was irradiated in standing and sitting postures.

  7. Conformal anomaly c-coefficients of superconformal 6d theories

    Energy Technology Data Exchange (ETDEWEB)

    Beccaria, Matteo [Dipartimento di Matematica e Fisica Ennio De Giorgi, Università del Salento & INFN,Via Arnesano, 73100 Lecce (Italy); Tseytlin, Arkady A. [The Blackett Laboratory, Imperial College,London SW7 2AZ (United Kingdom)

    2016-01-04

    We propose general relations between the conformal anomaly and the chiral (R-symmetry and gravitational) anomaly coefficients in 6d (1,0) superconformal theories. The suggested expressions for the three type B conformal anomaly c{sub i}-coefficients complement the expression for the type A anomaly a-coefficient found in http://arxiv.org/abs/1506.03807. We check them on several examples — the standard (1,0) hyper and tensor multiplets as well as some higher derivative short multiplets containing vector fields that generalize the superconformal 6d vector multiplet discussed in http://arxiv.org/abs/1506.08727. We also consider a family of higher derivative superconformal (2,0) 6d multiplets associated to 7d multiplets in the KK spectrum of 11d supergravity compactified on S{sup 4}. In particular, we prove that (2,0) 6d conformal supergravity coupled to 26 tensor multiplets is free of all chiral and conformal anomalies. We discuss some interacting (1,0) superconformal theories, predicting the c{sub i}-coefficients for the “E-string” theory on multiple M5-branes at E{sub 8} 9-brane and for the theory describing M5-branes at an orbifold singularity ℂ{sup 2}/Γ. Finally, we elaborate on holographic computation of subleading corrections to conformal anomaly coefficients coming from R{sup 2}+R{sup 3} terms in 7d effective action, revisiting, in particular, the (2,0) theory case.

  8. Analysis of vibration waveforms of electromechanical response to determine piezoelectric and electrostrictive coefficients.

    Science.gov (United States)

    Izumi, Tatsuya; Hagiwara, Manabu; Hoshina, Takuya; Takeda, Hiroaki; Tsurumi, Takaaki

    2012-08-01

    We developed a possible method to determine both coefficients of piezoelectricity (d) and electrostriction (M) at the same time by a waveform analysis of current and vibration velocity in the resonance state. The waveforms of the current and vibration velocity were theoretically described using the equations of motion and piezoelectric constitutive equations, considering the dissipation effect. The dissipation factor of the d coefficient and M coefficient is dielectric loss tangent tan δ. The waveforms measured in all of the ceramics, such as Pb(Zr,Ti)O(3) (PZT), Pb(Mg,Nb)O(3) (PMN), and 0.8Pb(Mg(1/3)Nb2/3)O(3)-0.2PbTiO(3) (PMN-PT), were well fitted with the calculated waveform. This fitting produced both the d and M coefficients, which agreed with those determined via the conventional methods. Moreover, the respective contributions of both piezoelectricity and electrostriction to the d value determined in the resonance-antiresonance method were clarified.

  9. Discharge Coefficient of Rectangular Short-Crested Weir with Varying Slope Coefficients

    Directory of Open Access Journals (Sweden)

    Yuejun Chen

    2018-02-01

    Full Text Available Rectangular short-crested weirs are widely used for simple structure and high discharge capacity. As one of the most important and influential factors of discharge capacity, side slope can improve the hydraulic characteristics of weirs at special conditions. In order to systemically study the effects of upstream and downstream slope coefficients S1 and S2 on overflow discharge coefficient in a rectangular short-crested weir the Volume of Fluid (VOF method and the Renormalization Group (RNG κ-ε turbulence model are used. In this study, the slope coefficient ranges from V to 3H:1V and each model corresponds to five total energy heads of H0 ranging from 8.0 to 24.0 cm. Comparisons of discharge coefficients and free surface profiles between simulated and laboratory results display a good agreement. The simulated results show that the difference of discharge coefficients will decrease with upstream slopes and increase with downstream slopes as H0 increases. For a given H0, the discharge coefficient has a convex parabolic relation with S1 and a piecewise linearity relation with S2. The maximum discharge coefficient is always obtained at S2 = 0.8. There exists a difference between upstream and downstream slope coefficients in the influence range of free surface curvatures. Furthermore, a proposed discharge coefficient equation by nonlinear regression is a function of upstream and downstream slope coefficients.

  10. Fault-tolerant conversion between adjacent Reed-Muller quantum codes based on gauge fixing

    Science.gov (United States)

    Quan, Dong-Xiao; Zhu, Li-Li; Pei, Chang-Xing; Sanders, Barry C.

    2018-03-01

    We design forward and backward fault-tolerant conversion circuits, which convert between the Steane code and the 15-qubit Reed-Muller quantum code so as to provide a universal transversal gate set. In our method, only seven out of a total 14 code stabilizers need to be measured, and we further enhance the circuit by simplifying some stabilizers; thus, we need only to measure eight weight-4 stabilizers for one round of forward conversion and seven weight-4 stabilizers for one round of backward conversion. For conversion, we treat random single-qubit errors and their influence on syndromes of gauge operators, and our novel single-step process enables more efficient fault-tolerant conversion between these two codes. We make our method quite general by showing how to convert between any two adjacent Reed-Muller quantum codes \\overline{\\textsf{RM}}(1,m) and \\overline{\\textsf{RM}}≤ft(1,m+1\\right) , for which we need only measure stabilizers whose number scales linearly with m rather than exponentially with m obtained in previous work. We provide the explicit mathematical expression for the necessary stabilizers and the concomitant resources required.

  11. Social conversational skills development in early implanted children.

    Science.gov (United States)

    Guerzoni, Letizia; Murri, Alessandra; Fabrizi, Enrico; Nicastri, Maria; Mancini, Patrizia; Cuda, Domenico

    2016-09-01

    Social conversational skills are a salient aspect of early pragmatic development in young children. These skills include two different abilities, assertiveness and responsiveness. This study investigated the development of these abilities in early implanted children and their relationships with lexical development and some language-sensitive variables. Prospective, observational, nonrandomized study. Participants included 28 children with congenital profound sensorineural hearing loss. The mean age at device activation was 13.3 months (standard deviation [SD] ±4.2). The Social-Conversational Skills Rating Scale was used to evaluate assertiveness and responsiveness. The MacArthur-Bates Communicative Development Inventory (Words and Sentences form) was used to analyze the lexical development. The device experience was 12 months for each child, and the mean age at testing was 25.9 months (SD ±4.6). Assertiveness and responsiveness scores were within the normal range of normal-hearing age-matched peers. Age at cochlear implant activation exerted a significant impact, with the highest scores associated to the youngest patients. The residual correlations between assertiveness and responsiveness with the lexical development were positive and strongly significant (r = 0.69 and 0.73, respectively). Preoperative hearing threshold demonstrated an associated significant coefficient on the assertiveness score. Age at diagnosis and maternal education level were not correlated with the social conversational skills. Early-implanted children developed social conversational skills that are similar to normal-hearing peers matched for age 1 year after device activation. Social conversational skills and lexical development were strongly correlated, but the present study design cannot specify the direction of this relationship. Children with better preoperative residual hearing exhibited better assertive ability. 4 Laryngoscope, 126:2098-2105, 2016. © 2015 The American Laryngological

  12. Simultaneous all-optical determination of molecular concentration and extinction coefficient.

    Science.gov (United States)

    Cho, Byungmoon; Tiwari, Vivek; Jonas, David M

    2013-06-04

    Absolute molecular number concentration and extinction coefficient are simultaneously determined from linear and nonlinear spectroscopic measurements. This method is based on measurements of absolute femtosecond pump-probe signals. Accounting for pulse propagation, we present a closed form expression for molecular number concentration in terms of absorbance, fluorescence, absolute pump-probe signal, and laser pulse parameters (pulse energy, spectrum, and spatial intensity profile); all quantities are measured optically. As in gravimetric and coulometric determinations of concentration, no standard samples are needed for calibration. The extinction coefficient can then be determined from the absorbance spectrum and the concentration. For fluorescein in basic methanol, the optically determined molar concentrations and extinction coefficients match gravimetric determinations to within 10% for concentrations from 0.032 to 0.540 mM, corresponding to absorbance from 0.06 to 1. In principle, this photonumeric method is extensible to transient chemical species for which other methods are not available.

  13. Intracavity quasi-phase-matched self-frequency conversion in a periodically poled Nd:Mg:LiNbO3 crystal

    International Nuclear Information System (INIS)

    Laptev, G D; Novikov, Aleksei A

    2001-01-01

    The theory of intracavity quasi-phase-matched self-frequency conversion in an active nonlinear periodically poled structure is developed. The processes of quasi-phase-matched self-frequency doubling, self-halving and mixing using the pump wave in a periodically poled Nd:Mg:LiNbO 3 crystal are studied. The dependences of the efficiency of nonlinear optical conversion in these processes on the reflection coefficient of the output mirror and on linear losses in the medium are investigated. (nonlinear optical phenomena)

  14. Characterization of energy conversion of multiferroic PFN and PFN:Mn

    Directory of Open Access Journals (Sweden)

    Lucjan Kozielski

    2013-12-01

    Full Text Available Characterization of energy conversion of multiferroic materials is concerned with multifunctional properties of materials, a topic that is fascinating from the scientific point of view and important for the modern technology. The complex characterization of multiferroic structures suffers at present from lack of a systematic experimental approach and deficiency of multifunctional magnetoelectric properties testing capabilities. Compactness and high frequency energy conversion capacity are the main reasons of invention and improvement of sophisticated materials which are prepared for high-speed computer memories and broadband transducer devices. As a consequence, one can easily notice an intense search for new materials for generation, transformation and amplification of magnetic and electric energies. In this scenario, the combination of excellent piezoelectric and magnetic properties makes lead iron niobate Pb(Fe1/2Nb1/2O3 (PFN an attractive host material for application in integrated magnetoelectric energy conversion applications. PFN multiferroic materials are attractive for commercial electroceramics due to high value of dielectric permittivity and magnetoelectric coefficients as well as relatively easy synthesis process. However, synthesis of PFN ceramics is mostly connected with formation of the secondary unwanted pyrochlore phase associated with dramatic decrease of ferroelectric properties. The authors have successfully reduced this negative phenomenon by Mn doping and finally present high piezoelectric and magnetoelectric energy conversion efficiency in fabricated PMFN ceramics.

  15. Quantitative Analysis of Isolated Single-Wall Carbon Nanotubes with Their Molar Absorbance Coefficients

    Directory of Open Access Journals (Sweden)

    Shota Kuwahara

    2014-01-01

    Full Text Available The molar absorbance coefficients of metallic, semiconducting, and (6,5 chirality enriched single-wall carbon nanotubes were evaluated by a spray technique combined with atomic force microscopy. Single-wall carbon nanotubes with isolated and a single predominant electronic type were obtained by using the density-gradient ultracentrifugation technique. In the visible region, all coefficients had similar values around 2–5 × 109/mL mol−1 cm−1, independent of their diameter distribution and the electronic types of single-wall carbon nanotubes, and the εS22/εM11  and εS11/εM11 were estimated to be 1.0 and 4.0, respectively. The coefficient strongly depends on the length of single-wall carbon nanotubes, independent of their electronic types and chirality.

  16. Neoclassical transport coefficients for tokamaks with bean-shaped flux surfaces

    International Nuclear Information System (INIS)

    Chang, C.S.; Kaye, S.M.

    1990-11-01

    Simple analytic representations of the neoclassical transport coefficients for indented flux surfaces are presented. It is shown that a transport coefficient for an indented flux surface can be expressed in terms of a linear combination of the previously known transport coefficients for two nonindented flux surfaces. Numerical calculations based on actual equilibria from the PBX-M tokamak indicate that, even for modestly indented flux surfaces, the ion neoclassical thermal transport can be over a factor of two smaller than in a circular plasma with the same midplane radius or with the equivalent areas. 6 refs., 5 figs., 1 tab

  17. Comparison of Radiation Dose Rates with the Flux to Dose Conversion Factors Recommended in ICRP-74 and ICRP-116

    International Nuclear Information System (INIS)

    Jeong, Hae Sun; Kil, A Reum; Lee, Jo Eun; Jeong, Hyo Joon; Kim, Eun Han; Han, Moon Hee; Hwang, Won Tae

    2016-01-01

    The evaluation of radiation shielding has been performed for the design and maintenance of various facilities using radioactive sources such as nuclear fuel, accelerator, and radionuclide. The conversion of flux to dose mainly used in nuclear and radiation fields has been generally made with the dose coefficients presented in ICRP Publication 74 (ICRP- 74), which are produced based on ICRP Publication 60. On the other hand, ICRP Publication 116 (ICRP-116), which adopts the protection system of ICRP Publication 103, has recently been published and provides the dose conversion coefficients calculated with a variety of Monte Carlo codes. The coefficients have more than an update of those in ICRP-74, including new particle types and a greatly expanded energy range. In this study, a shielding evaluation of a specific container for neutron and gamma sources was performed with the MCNP6 code. The dose rates from neutron and gamma-ray sources were calculated using the MCNP6 codes, and these results were based on the flux to dose conversion factors recommended in ICRP-74 and ICRP-116. As a result, the dose rates evaluated with ICRP-74 were generally shown higher than those with ICRP-116. For neutrons, the difference is mainly occurred by the decrease of radiation weighting factors in a part of energy ranges in the ICRP-116 recommendations. For gamma-rays, the ICRP-74 recommendation applied with the kerma approximation leads to overestimated results than the other assessment

  18. Modeling of large aperture third harmonic frequency conversion of high power Nd:glass laser systems

    International Nuclear Information System (INIS)

    Henesian, M.A.; Wegner, P.J.; Speck, D.R.; Bibeau, C.; Ehrlich, R.B.; Laumann, C.W.; Lawson, J.K.; Weiland, T.L.

    1991-01-01

    To provide high-energy, high-power beams at short wavelengths for inertial-confinement-fusion experiments, we routinely convert the 1.053-μm output of the Nova, Nd:phosphate-glass, laser system to its third-harmonic wavelength. We describe performance and conversion efficiency modeling of the 3 x 3 arrays potassium-dihydrogen-phosphate crystal plates used for type II/type II phase-matched harmonic conversion of Nova 0.74-m diameter beams, and an alternate type I/type II phase-matching configuration that improves the third-harmonic conversion efficiency. These arrays provide energy conversion of up to 65% and intensity conversion to 70%. 19 refs., 11 figs

  19. The Use of Alternative Regression Methods in Social Sciences and the Comparison of Least Squares and M Estimation Methods in Terms of the Determination of Coefficient

    Science.gov (United States)

    Coskuntuncel, Orkun

    2013-01-01

    The purpose of this study is two-fold; the first aim being to show the effect of outliers on the widely used least squares regression estimator in social sciences. The second aim is to compare the classical method of least squares with the robust M-estimator using the "determination of coefficient" (R[superscript 2]). For this purpose,…

  20. A multicenter experience with generic tacrolimus conversion.

    Science.gov (United States)

    McDevitt-Potter, Lisa M; Sadaka, Basma; Tichy, Eric M; Rogers, Christin C; Gabardi, Steven

    2011-09-27

    The first generic tacrolimus product gained Food and Drug Administration approval in August 2009. This prospective, observational trial sought to determine the need for dose titrations and measure drug cost savings on conversion to generic tacrolimus. Transplant recipients on stable tacrolimus doses were converted from brand to generic tacrolimus on a mg:mg basis. Data were collected at the time of generic conversion (study arm) and at a time point exactly 6 months before conversion (control arm) for all subjects. Seventy conversions from four centers are reported. Subjects were a mean of 70 months after kidney (n=37), liver (n=28), or multiorgan (n=5) transplant. In the study arm, mean tacrolimus doses were 4.4 and 4.5 mg/d and mean tacrolimus trough concentrations were 5.8 and 5.9 ng/mL before and after conversion, respectively. In the control arm, mean tacrolimus doses were 4.6 and 4.6 mg/d and mean tacrolimus trough concentrations were 6.1 and 5.9 ng/mL before and after the control time point, respectively. Dose titrations occurred in five patients (7%) in the control arm and 15 patients (21%) in the study arm (P=0.028). Mean monthly drug costs were $645 for brand, $593 for generic, and $595 for generic after dose titrations. Mean monthly patient copays were $38 for brand and $15 for generic. These cumulative data show that dose requirements and trough levels are similar between brand and generic tacrolimus and that generic substitution allows for savings. However, postconversion monitoring is prudent as patients may require dose titration.

  1. Nozzle geometry variations on the discharge coefficient

    Directory of Open Access Journals (Sweden)

    M.M.A. Alam

    2016-03-01

    Full Text Available Numerical works have been conducted to investigate the effect of nozzle geometries on the discharge coefficient. Several contoured converging nozzles with finite radius of curvatures, conically converging nozzles and conical divergent orifices have been employed in this investigation. Each nozzle and orifice has a nominal exit diameter of 12.7×10−3 m. A 3rd order MUSCL finite volume method of ANSYS Fluent 13.0 was used to solve the Reynolds-averaged Navier–Stokes equations in simulating turbulent flows through various nozzle inlet geometries. The numerical model was validated through comparison between the numerical results and experimental data. The results obtained show that the nozzle geometry has pronounced effect on the sonic lines and discharge coefficients. The coefficient of discharge was found differ from unity due to the non-uniformity of flow parameters at the nozzle exit and the presence of boundary layer as well.

  2. Conversion of optical wave polarizations in 1D finite anisotropic photonic crystal

    International Nuclear Information System (INIS)

    Ouchani, N.; Nougaoui, N.; Daoudi, A.; Bria, D.

    2006-07-01

    We show that by using one dimensional anisotropic photonic structures, it is possible to realize optical wave polarization conversion by transmission or by reflection. Thus a single incident S(P) polarized plane wave can produce a single reflected P(S) polarized wave and a single transmitted P(S) polarized wave. This polarization conversion property can be fulfilled with a simple finite superlattice constituted by anisotropic dielectric materials. We discuss the appropriate choices of the material and geometrical properties to realize such structures. The transmission and reflection coefficients are discussed in relation with the dispersion curves of the finite structure embedded between two isotropic substrates. Both transmission and reflection coefficients are calculated in the framework of Green's function method. The amplitude and the polarization characteristics of reflected and transmitted waves are determined as function of frequency ω , and wave vector k parallel ( parallel to the interface) and the orientations of the principal axes of the layers constituting the SL. Moreover, this structure exhibits a coupling between S and P waves that does not exist in SL composed only of isotropic materials. Specific applications of these results are given for a superlattice consisting of alternating biaxial anisotropic layers NaNO 2 /SbSi sandwiched between two identical semi-infinite isotropic media. (author)

  3. Relationship between the Kubelka-Munk scattering and radiative transfer coefficients.

    Science.gov (United States)

    Thennadil, Suresh N

    2008-07-01

    The relationship between the Kubelka-Munk (K-M) and the transport scattering coefficient is obtained through a semi-empirical approach. This approach gives the same result as that given by Gate [Appl. Opt.13, 236 (1974)] when the incident beam is diffuse. This result and those given by Star et al. [Phys. Med. Biol.33, 437 (1988)] and Brinkworth [Appl. Opt.11, 1434 (1972)] are compared with the exact solution of the radiative transfer equation over a large range of optical properties. It is found that the latter expressions, which include an absorption component, do not give accurate results over the range considered. Using the semi-empirical approach, the relationship between the K-M and the transport scattering coefficient is derived for the case where the incident light is collimated. It is shown that although the K-M equation is derived based on diffuse incident light, it can also represent very well the reflectance from a slab of infinite thickness when the incident light is collimated. However, in this case the relationship between the coefficients has to include a function that is dependent on the anisotropy factor. Analysis indicates that the K-M transform achieves the objective of obtaining a measure that gives the ratio of absorption to scattering effects for both diffuse and collimated incident beams over a large range of optical properties.

  4. Heat transfer coefficient as parameter describing ability of insulating liquid to heat transfer

    Science.gov (United States)

    Nadolny, Zbigniew; Gościński, Przemysław; Bródka, Bolesław

    2017-10-01

    The paper presents the results of the measurements of heat transfer coefficient of insulating liquids used in transformers. The coefficient describes an ability of the liquid to heat transport. On the basis of the coefficient, effectiveness of cooling system of electric power devices can be estimated. Following liquids were used for the measurements: mineral oil, synthetic ester and natural ester. It was assumed that surface heat load is about 2500 W·m-2, which is equal the load of transformer windings. A height of heat element was 1.6 m, because it makes possible steady distribution of temperature on its surface. The measurements of heat transfer coefficient was made as a function of various position of heat element (vertical, horizontal). In frame of horizontal position of heat element, three suppositions were analysed: top, bottom, and side.

  5. Heat transfer coefficient as parameter describing ability of insulating liquid to heat transfer

    Directory of Open Access Journals (Sweden)

    Nadolny Zbigniew

    2017-01-01

    Full Text Available The paper presents the results of the measurements of heat transfer coefficient of insulating liquids used in transformers. The coefficient describes an ability of the liquid to heat transport. On the basis of the coefficient, effectiveness of cooling system of electric power devices can be estimated. Following liquids were used for the measurements: mineral oil, synthetic ester and natural ester. It was assumed that surface heat load is about 2500 W·m-2, which is equal the load of transformer windings. A height of heat element was 1.6 m, because it makes possible steady distribution of temperature on its surface. The measurements of heat transfer coefficient was made as a function of various position of heat element (vertical, horizontal. In frame of horizontal position of heat element, three suppositions were analysed: top, bottom, and side.

  6. Temperature effects on diffusion coefficient for 6-gingerol and 6-shogaol in subcritical water extraction

    Science.gov (United States)

    Ilia Anisa, Nor; Azian, Noor; Sharizan, Mohd; Iwai, Yoshio

    2014-04-01

    6-gingerol and 6-shogaol are the main constituents as anti-inflammatory or bioactive compounds from zingiber officinale Roscoe. These bioactive compounds have been proven for inflammatory disease, antioxidatives and anticancer. The effect of temperature on diffusion coefficient for 6-gingerol and 6-shogaol were studied in subcritical water extraction. The diffusion coefficient was determined by Fick's second law. By neglecting external mass transfer and solid particle in spherical form, a linear portion of Ln (1-(Ct/Co)) versus time was plotted in determining the diffusion coefficient. 6-gingerol obtained the higher yield at 130°C with diffusion coefficient of 8.582x10-11 m2/s whilst for 6-shogaol, the higher yield and diffusion coefficient at 170°C and 19.417 × 10-11 m2/s.

  7. High-capacity lithium-ion battery conversion cathodes based on iron fluoride nanowires and insights into the conversion mechanism.

    Science.gov (United States)

    Li, Linsen; Meng, Fei; Jin, Song

    2012-11-14

    The increasing demands from large-scale energy applications call for the development of lithium-ion battery (LIB) electrode materials with high energy density. Earth abundant conversion cathode material iron trifluoride (FeF(3)) has a high theoretical capacity (712 mAh g(-1)) and the potential to double the energy density of the current cathode material based on lithium cobalt oxide. Such promise has not been fulfilled due to the nonoptimal material properties and poor kinetics of the electrochemical conversion reactions. Here, we report for the first time a high-capacity LIB cathode that is based on networks of FeF(3) nanowires (NWs) made via an inexpensive and scalable synthesis. The FeF(3) NW cathode yielded a discharge capacity as high as 543 mAh g(-1) at the first cycle and retained a capacity of 223 mAh g(-1) after 50 cycles at room temperature under the current of 50 mA g(-1). Moreover, high-resolution transmission electron microscopy revealed the existence of continuous networks of Fe in the lithiated FeF(3) NWs after discharging, which is likely an important factor for the observed improved electrochemical performance. The loss of active material (FeF(3)) caused by the increasingly ineffective reconversion process during charging was found to be a major factor responsible for the capacity loss upon cycling. With the advantages of low cost, large quantity, and ease of processing, these FeF(3) NWs are not only promising battery cathode materials but also provide a convenient platform for fundamental studies and further improving conversion cathodes in general.

  8. Apparent Coefficient of Friction of Wheat on Denim.

    Science.gov (United States)

    Schwab, Charles V

    2017-07-31

    Calculation of the extraction force for a grain entrapment victim requires a coefficient of friction between the grain and the surface of the victim. Because denim is a common fabric for the work clothes that cover entrapment victims, the coefficient of friction between grain and denim becomes necessary. The purpose of this research was to calculate the apparent coefficient of friction of wheat on denim fabric using a proven procedure. The expectation is to improve the current understanding of conditions that influence extraction forces for victims buried in wheat. The apparent coefficient of friction of wheat on denim fabric was calculated to be 0.167 with a standard deviation of ±0.013. The wheat had a moisture content of 10.7% (w.b.) and bulk density of 778.5 kg m-3. The apparent coefficient of friction of wheat on denim was not significantly affected by pull speeds of 0.004, 0.008, and 0.021 mm s-1 nor normal grain pressures of 3.2, 4.8, 6.3, 7.9, and 11.1 kPa. This is a beginning of understanding the conditions that influence the extraction forces for grain entrapment victims. Copyright© by the American Society of Agricultural Engineers.

  9. Comparison of wavelength conversion efficiency between silicon waveguide and microring resonator

    DEFF Research Database (Denmark)

    Xiong, Meng; Ding, Yunhong; Ou, Haiyan

    2016-01-01

    Wavelength conversion based on degenerate four-wave mixing (FWM) was demonstrated and compared between silicon nanowire and microring resonator (MRR). 15 dB enhancement of conversion efficiency (CE) with relatively low input pump power (5 mW) was achieved experimentally in an MRR. The impacts...

  10. Computation of Clebsch-Gordan and Gaunt coefficients using binomial coefficients

    International Nuclear Information System (INIS)

    Guseinov, I.I.; Oezmen, A.; Atav, Ue

    1995-01-01

    Using binomial coefficients the Clebsch-Gordan and Gaunt coefficients were calculated for extremely large quantum numbers. The main advantage of this approach is directly calculating these coefficients, instead of using recursion relations. Accuracy of the results is quite high for quantum numbers l 1 , and l 2 up to 100. Despite direct calculation, the CPU times are found comparable with those given in the related literature. 11 refs., 1 fig., 2 tabs

  11. High conversion burner type reactor

    International Nuclear Information System (INIS)

    Higuchi, Shin-ichi; Kawashima, Masatoshi

    1987-01-01

    Purpose: To simply and easily dismantle and reassemble densified fuel assemblies taken out of a high conversion ratio area thereby improve the neutron and fuel economy. Constitution: The burner portion for the purpose of fuel combustion is divided into a first burner region in adjacent with the high conversion ratio area at the center of the reactor core, and a second burner region formed to the outer circumference thereof and two types of fuels are charged therein. Densified fuel assemblies charged in the high conversion ratio area are separatably formed as fuel assemblies for use in the two types of burners. In this way, dense fuel assembly is separated into two types of fuel assemblies for use in burner of different number and arranging density of fuel elements which can be directly charged to the burner portion and facilitate the dismantling and reassembling of the fuel assemblies. Further, since the two types of fuel assemblies are charged in the burner portion, utilization factor for the neutron fuels can be improved. (Kamimura, M.)

  12. Uranium conversion

    International Nuclear Information System (INIS)

    Oliver, Lena; Peterson, Jenny; Wilhelmsen, Katarina

    2006-03-01

    FOI, has performed a study on uranium conversion processes that are of importance in the production of different uranium compounds in the nuclear industry. The same conversion processes are of interest both when production of nuclear fuel and production of fissile material for nuclear weapons are considered. Countries that have nuclear weapons ambitions, with the intention to produce highly enriched uranium for weapons purposes, need some degree of uranium conversion capability depending on the uranium feed material available. This report describes the processes that are needed from uranium mining and milling to the different conversion processes for converting uranium ore concentrate to uranium hexafluoride. Uranium hexafluoride is the uranium compound used in most enrichment facilities. The processes needed to produce uranium dioxide for use in nuclear fuel and the processes needed to convert different uranium compounds to uranium metal - the form of uranium that is used in a nuclear weapon - are also presented. The production of uranium ore concentrate from uranium ore is included since uranium ore concentrate is the feed material required for a uranium conversion facility. Both the chemistry and principles or the different uranium conversion processes and the equipment needed in the processes are described. Since most of the equipment that is used in a uranium conversion facility is similar to that used in conventional chemical industry, it is difficult to determine if certain equipment is considered for uranium conversion or not. However, the chemical conversion processes where UF 6 and UF 4 are present require equipment that is made of corrosion resistant material

  13. Computation of the Coupling Resonance Driving term f1001 and the coupling coefficient C from turn-by-turn single-BPM data.

    CERN Document Server

    Franchi, A; Vanbavinkhove, G; CERN. Geneva. BE Department

    2010-01-01

    In this note we show how to compute the Resonance Driving Term (RDT) f1001, the local resonance term chi 1010 and the coupling coefficient C from the spectrum of turn-by-turn single-BPM data. The harmonic analysis of real coordinate x(y) is model independent, conversely to the the analysis of the complex Courant-Snyder coordinate hx,- = x-ipx. From the computation of f1001 along the ring is closely related to the global coupling coefficient C, but it is affected by an intrinsic error, discussed in this note.

  14. Sexy gene conversions: locating gene conversions on the X-chromosome.

    Science.gov (United States)

    Lawson, Mark J; Zhang, Liqing

    2009-08-01

    Gene conversion can have a profound impact on both the short- and long-term evolution of genes and genomes. Here, we examined the gene families that are located on the X-chromosomes of human (Homo sapiens), chimpanzee (Pan troglodytes), mouse (Mus musculus) and rat (Rattus norvegicus) for evidence of gene conversion. We identified seven gene families (WD repeat protein family, Ferritin Heavy Chain family, RAS-related Protein RAB-40 family, Diphosphoinositol polyphosphate phosphohydrolase family, Transcription Elongation Factor A family, LDOC1-related family, Zinc Finger Protein ZIC, and GLI family) that show evidence of gene conversion. Through phylogenetic analyses and synteny evidence, we show that gene conversion has played an important role in the evolution of these gene families and that gene conversion has occurred independently in both primates and rodents. Comparing the results with those of two gene conversion prediction programs (GENECONV and Partimatrix), we found that both GENECONV and Partimatrix have very high false negative rates (i.e. failed to predict gene conversions), which leads to many undetected gene conversions. The combination of phylogenetic analyses with physical synteny evidence exhibits high resolution in the detection of gene conversions.

  15. Diffusion of helium and estimated diffusion coefficients of hydrogen dissolved in water-saturated, compacted Ca-montmorillonite

    International Nuclear Information System (INIS)

    Higashihara, Tomohiro; Sato, Seichi; Ohashi, Hiroshi; Otsuka, Teppei

    2001-01-01

    The diffusion coefficients of hydrogen gas dissolved in water-saturated, compacted montmorillonite are required to estimate the performance of bentonite buffer materials for geological disposal of nuclear waste. As part of the effort to determine the diffusion coefficients, the diffusion coefficients of helium in water-saturated, compacted calcium montmorillonite (Ca-montmorillonite) were determined as a function of dry density, 0.78 to 1.37x10 3 kg m -3 , by a transient diffusion method. The diffusion coefficients were from 8.3x10 -10 m 2 s -1 at 0.78x10 3 kgm -3 to 2.8x10 -10 m 2 s -1 at 1.37x10 3 kgm -3 . The data obtained by this diffusion experiment of helium were highly reproducible. The diffusion coefficients of helium in Ca-montmorillonite were somewhat larger than those previously obtained for helium in sodium montmorillonite (Na-montmorillonite). The diffusion coefficients of hydrogen gas in the montmorillonites were roughly estimated using the diffusion coefficients of helium. These estimates were based on assumptions that both helium and hydrogen molecules are non-adsorptive and that the geometric factors in the compacted montmorillonites are approximately the same for diffusion of helium and diffusion of hydrogen. (author)

  16. Geographic differences in time to culture conversion in liquid media: Tuberculosis Trials Consortium study 28. Culture conversion is delayed in Africa.

    Directory of Open Access Journals (Sweden)

    William R Mac Kenzie

    2011-04-01

    Full Text Available Tuberculosis Trials Consortium Study 28, was a double blind, randomized, placebo-controlled, phase 2 clinical trial examining smear positive pulmonary Mycobacterium tuberculosis. Over the course of intensive phase therapy, patients from African sites had substantially delayed and lower rates of culture conversion to negative in liquid media compared to non-African patients. We explored potential explanations of this finding.In TBTC Study 28, protocol-correct patients (n = 328 provided spot sputum specimens for M. tuberculosis culture in liquid media, at baseline and weeks 2, 4, 6 and 8 of study therapy. We compared sputum culture conversion for African and non-African patients stratified by four baseline measures of disease severity: AFB smear quantification, extent of disease on chest radiograph, cavity size and the number of days to detection of M. tuberculosis in liquid media using the Kaplan-Meier product-limit method. We evaluated specimen processing and culture procedures used at 29 study laboratories serving 27 sites.African TB patients had more extensive disease at enrollment than non-African patients. However, African patients with the least disease by the 4 measures of disease severity had conversion rates on liquid media that were substantially lower than conversion rates in non-African patients with the greatest extent of disease. HIV infection, smoking and diabetes did not explain delayed conversion in Africa. Some inter-site variation in laboratory processing and culture procedures within accepted practice for clinical diagnostic laboratories was found.Compared with patients from non-African sites, African patients being treated for TB had delayed sputum culture conversion and lower sputum conversion rates in liquid media that were not explained by baseline severity of disease, HIV status, age, smoking, diabetes or race. Further investigation is warranted into whether modest variation in laboratory processes substantially

  17. Diffusion coefficients of radon in candidate soils for covering uranium mill tailings

    International Nuclear Information System (INIS)

    Kalkwarf, D.R.; Silker, W.B.

    1983-10-01

    Diffusion coefficients were measured for radon in 34 soils that had been identified by uranium mill personnel as candidate soils for covering their tailings piles in order to reduce radon emission. The coefficients referred to diffusion in the total pore space of the soils. They were measured by a steady-state method using soil columns compacted to greater than 80% of their Proctor maximum packing densities, but with moisture contents generally less than would be expected at a tailings site. Three published empirical equations relating diffusion coefficients to soil moisture and porosity were tested with these data. The best fir was obtained with the equation: D = 0.70 exp [-4(m-mP 2 +m 5 )] in which P is the dry porosity of the soil and m is its moisture saturation, i.e. the fraction of pore volume filled with water. This equation was used to extrapolate measured coefficients to values expected at soil-moisture contents representative of tailings sites in the western United States. Extrapolated values for silty sands and clayey sands range from 0.004 to 0.06 cm 2 /s where w, the weight ratio of water to dry soil, is expected to vary from 0.04 to 0.09. Values for inorganic silts and clays ranged from 0.001 to 0.02 cm 2 /s where w is expected to vary from 0.10 to 0.13. 8 references, 1 figure, 1 table

  18. The Peltier and Zeebeck coefficients of the Cd-CdI2 melt

    International Nuclear Information System (INIS)

    Kuzyakin, E.B.; Kuz'minskij, E.V.

    1979-01-01

    For the CdI 2 -Cd melt with the usage of molybdenum ''inert'' electrodes in the temperature range of 670-850 K and metal cadmium concentration of 0-5 mol % experimentally determined are the Peltier (PI = 0.67+0.07 V at T = 722 K and 0.23 mol %) and Zeebeck (epsilonsub(in) 1.175+-0.107 mV/deg -1 at 0.20 mol % Cd and T = 700-780 K) coefficients. Calculated is heat transfer coefficient from the electrode to the melt (a = 65+-10 W/m 2 K), reaffirmed is applicability of the second Thomson ratio (PI = Txepsilonsub(in)). It is shown that the method of non-stationary temperature waves, suggested for the Peltier coefficient determination can be applied for evaluation of metal solubility values in their molten salts

  19. Effect of toroidicity during lower hybrid mode conversion

    International Nuclear Information System (INIS)

    Riyopoulos, S.; Mahajan, S.

    1985-11-01

    The effect of toroidicity during lower hybrid mode conversion is examined by treating the wave propagation in an inhomogeneous medium as an eigenvalue problem for ω 2 (m,n),m,n poloidal and toroidal wave numbers. Since the frequency regime near ω 2 = ω/sub LH/ 2 is an accumulation point for the eigenvalue spectrum, the degenerate perturbation technique must be applied. The toroidal eigenmodes are constructed by a zeroth order superposition of monochromatic solutions with different poloidal dependence m, thus they generically exhibit a wide spectrum in k/sub parallel/ for given fixed ω 2 even for small inverse aspect ratio epsilon. In case that the average is in the neighborhood of k/sub min/, the minimum wave number for accessibility of the mode conversion regime, it is expected that excitation of toroidal modes rather than geometric optics will determine the wave coupling to the plasma

  20. Temperature effects on diffusion coefficient for 6-gingerol and 6-shogaol in subcritical water extraction

    International Nuclear Information System (INIS)

    Anisa, Nor Ilia; Azian, Noor; Sharizan, Mohd; Iwai, Yoshio

    2014-01-01

    6-gingerol and 6-shogaol are the main constituents as anti-inflammatory or bioactive compounds from zingiber officinale Roscoe. These bioactive compounds have been proven for inflammatory disease, antioxidatives and anticancer. The effect of temperature on diffusion coefficient for 6-gingerol and 6-shogaol were studied in subcritical water extraction. The diffusion coefficient was determined by Fick's second law. By neglecting external mass transfer and solid particle in spherical form, a linear portion of Ln (1-(Ct/Co)) versus time was plotted in determining the diffusion coefficient. 6-gingerol obtained the higher yield at 130°C with diffusion coefficient of 8.582x10 −11 m 2 /s whilst for 6-shogaol, the higher yield and diffusion coefficient at 170°C and 19.417 × 10 −11 m 2 /s.

  1. The Role of Conversation Policy in Carrying Out Agent Conversations

    International Nuclear Information System (INIS)

    Link, Hamilton E.; Phillips, Laurence R.

    1999-01-01

    Structured conversation diagrams, or conversation specifications, allow agents to have predictable interactions and achieve predefined information-based goals, but they lack the flexibility needed to function robustly in an unpredictable environment. We propose a mechanism that combines a typical conversation structure with a separately established policy to generate an actual conversation. The word ''policy'' connotes a high-level direction external to a specific planned interaction with the environment. Policies, which describe acceptable procedures and influence decisions, can be applied to broad sets of activity. Based on their observation of issues related to a policy, agents may dynamically adjust their communication patterns. The policy object describes limitations, constraints, and requirements that may affect the conversation in certain circumstances. Using this new mechanism of interaction simplifies the description of individual conversations and allows domain-specific issues to be brought to bear more easily during agent communication. By following the behavior of the conversation specification when possible and deferring to the policy to derive behavior in exceptional circumstances, an agent is able to function predictably under normal situations and still act rationally in abnormal situations. Different conversation policies applied to a given conversation specification can change the nature of the interaction without changing the specification

  2. Observation and Numerical Experiments for Drag Coefficient Under Typhoon Wind Forcing

    Institute of Scientific and Technical Information of China (English)

    CAO Huiqiu; ZHOU Liangming; LI Shuiqing; WANG Zhifeng

    2017-01-01

    This paper presents a study on drag coefficients under typhoon wind forcing based on observations and numerical experiments.The friction velocity and wind speed are measured at a marine observation platform in the South China Sea.Three typhoons:SOULIK (2013),TRAMI (2013) and FITOW (2013) are observed at a buoy station in the northeast sea area of Pingtan Island.A new parameterization is formulated for the wind drag coefficient as a function of wind speed.It is found that the drag coefficient (Ca) increases linearly with the slope of 0.083× 10-3 for wind speed less than 24 m s-1.To investigate the drag coefficient under higher wind conditions,three numerical experiments are implemented for these three typhoons using SWAN wave model.The wind input data are objective reanalysis datasets,which are assimilated with many sources and provided every six hours with the resolution of 0.125° ×0.125°.The numerical simulation results show a good agreement with wave observation data under typhoon wind forcing.The results indicate that the drag coefficient levels off with the linear slope of 0.012× 10-3 for higher wind speeds (less than 34 m s-1) and the new parameterization improvese the simulation accuracy compared with the Wu (1982) default used in SWAN.

  3. Dose conversion of radon exposure according to new epidemiological findings

    International Nuclear Information System (INIS)

    Tomasek, L.; Rogel, A.; Laurier, D.; Tirmarche, M.

    2008-01-01

    In 1993, ICRP-65 recommended that dose conversion of radon exposure should be based on the comparison of detriments between radon exposure and effective dose. The lifetime detriment from the radon exposure was projected according to the epidemiological studies of uranium miners then available. The projection model (GSF) was multiplicative with temporal and age-at-exposure modification. Since 1993, new studies of uranium miners have appeared and many original studies were updated. In addition, projections of the risk have been improved by including further modifying factors as for instance in BEIR VI. New analyses were completed in the Czech and French studies of uranium miners with accurate estimates of exposures based on extensive radon measurements. The resulting estimates of excess absolute lifetime risk per unit exposure in working level months (WLM) from these models lead to dose conversion of 10 mSv WLM -1 for the BEIR VI model and 8 mSv WLM -1 for the joint Czech-French model in contrast to the conversion of 5 mSv WLM -1 for the GSF model. (authors)

  4. Self-induced neutrino flavor conversion without flavor mixing

    International Nuclear Information System (INIS)

    Chakraborty, S.; Izaguirre, I.; Raffelt, G.G.; Hansen, R. S.

    2016-01-01

    Neutrino-neutrino refraction in dense media can cause self-induced flavor conversion triggered by collective run-away modes of the interacting flavor oscillators. The growth rates were usually found to be of order a typical vacuum oscillation frequency Δ m 2 /2E. However, even in the simple case of a ν e beam interacting with an opposite-moving ν-bar e beam, and allowing for spatial inhomogeneities, the growth rate of the fastest-growing Fourier mode is of order μ=√2 G F  n ν , a typical ν–ν interaction energy. This growth rate is much larger than the vacuum oscillation frequency and gives rise to flavor conversion on a much shorter time scale. This phenomenon of 'fast flavor conversion' occurs even for vanishing Δ m 2 /2E and thus does not depend on energy, but only on the angle distributions. Moreover, it does not require neutrinos to mix or to have masses, except perhaps for providing seed disturbances. We also construct a simple homogeneous example consisting of intersecting beams and study a schematic supernova model proposed by Ray Sawyer, where ν e and ν-bar e emerge with different zenith-angle distributions, the key ingredient for fast flavor conversion. What happens in realistic astrophysical scenarios remains to be understood

  5. Thermoelectric Energy Conversion: Materials, Devices, and Systems

    International Nuclear Information System (INIS)

    Chen, Gang

    2015-01-01

    This paper will present a discussion of challenges, progresses, and opportunities in thermoelectric energy conversion technology. We will start with an introduction to thermoelectric technology, followed by discussing advances in thermoelectric materials, devices, and systems. Thermoelectric energy conversion exploits the Seebeck effect to convert thermal energy into electricity, or the Peltier effect for heat pumping applications. Thermoelectric devices are scalable, capable of generating power from nano Watts to mega Watts. One key issue is to improve materials thermoelectric figure- of-merit that is linearly proportional to the Seebeck coefficient, the square of the electrical conductivity, and inversely proportional to the thermal conductivity. Improving the figure-of-merit requires good understanding of electron and phonon transport as their properties are often contradictory in trends. Over the past decade, excellent progresses have been made in the understanding of electron and phonon transport in thermoelectric materials, and in improving existing and identify new materials, especially by exploring nanoscale size effects. Taking materials to real world applications, however, faces more challenges in terms of materials stability, device fabrication, thermal management and system design. Progresses and lessons learnt from our effort in fabricating thermoelectric devices will be discussed. We have demonstrated device thermal-to-electrical energy conversion efficiency ∼10% and solar-thermoelectric generator efficiency at 4.6% without optical concentration of sunlight (Figure 1) and ∼8-9% efficiency with optical concentration. Great opportunities exist in advancing materials as well as in using existing materials for energy efficiency improvements and renewable energy utilization, as well as mobile applications. (paper)

  6. Study of Temperature Coefficients for Parameters of Photovoltaic Cells

    Directory of Open Access Journals (Sweden)

    Daniel Tudor Cotfas

    2018-01-01

    Full Text Available The temperature is one of the most important factors which affect the performance of the photovoltaic cells and panels along with the irradiance. The current voltage characteristics, I-V, are measured at different temperatures from 25°C to 87°C and at different illumination levels from 400 to 1000 W/m2, because there are locations where the upper limit of the photovoltaic cells working temperature exceeds 80°C. This study reports the influence of the temperature and the irradiance on the important parameters of four commercial photovoltaic cell types: monocrystalline silicon—mSi, polycrystalline silicon—pSi, amorphous silicon—aSi, and multijunction InGaP/InGaAs/Ge (Emcore. The absolute and normalized temperature coefficients are determined and compared with their values from the related literature. The variation of the absolute temperature coefficient function of the irradiance and its significance to accurately determine the important parameters of the photovoltaic cells are also presented. The analysis is made on different types of photovoltaics cells in order to understand the effects of technology on temperature coefficients. The comparison between the open-circuit voltage and short-circuit current was also performed, calculated using the temperature coefficients, determined, and measured, in various conditions. The measurements are realized using the SolarLab system, and the photovoltaic cell parameters are determined and compared using the LabVIEW software created for SolarLab system.

  7. Automated quantification of Epstein-Barr Virus in whole blood of hematopoietic stem cell transplant patients using the Abbott m2000 system.

    Science.gov (United States)

    Salmona, Maud; Fourati, Slim; Feghoul, Linda; Scieux, Catherine; Thiriez, Aline; Simon, François; Resche-Rigon, Matthieu; LeGoff, Jérôme

    2016-08-01

    Accurate quantification of Epstein-Barr virus (EBV) load in blood is essential for the management of post-transplant lymphoproliferative disorders. The automation of DNA extraction and amplification may improve accuracy and reproducibility. We evaluated the EBV PCR Kit V1 with fully automated DNA extraction and amplification on the m2000 system (Abbott assay). Conversion factor between copies and international units (IU), lower limit of quantification, imprecision and linearity were determined in a whole blood (WB) matrix. Results from 339 clinical WB specimens were compared with a home-brew real-time PCR assay used in our laboratory (in-house assay). The conversion factor between copies and IU was 3.22 copies/IU. The lower limit of quantification (LLQ) was 1000 copies/mL. Intra- and inter-assay coefficients of variation were 3.1% and 7.9% respectively for samples with EBV load higher than the LLQ. The comparison between Abbott assay and in-house assay showed a good concordance (kappa = 0.77). Loads were higher with the Abbott assay (mean difference = 0.62 log10 copies/mL). The EBV PCR Kit V1 assay on the m2000 system provides a reliable and easy-to-use method for quantification of EBV DNA in WB. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Induration and Biot’s Coefficient of Palaeogene Limestone

    DEFF Research Database (Denmark)

    Andreassen, Katrine Alling

    2017-01-01

    In engineering geology and classification of rock masses for civil engineering purposes, the degree of induration for a rock serves as a useful classification parameter. Induration is a measure of how well the grains of a sedimentary rock are cemented together - from loosely cemented/soft rock...... to very competent/slightly metamorphic rock. The Biot coefficient links to the degree of cementation in the capacity of how it relates the elastic deformations with the change in pore pressure. A hypothesis is that the degree of induration could be correlated to the magnitude of the Biot coefficient....... This is tested on 11 Copenhagen Limestone specimens of varying porosity and densities obtained from one borehole with a limestone interval of 30 m. Their induration varies from H2 to H5. Elastic wave propagation measurements are used to establish the Biot coefficient and determination of the mineralogy for H5...

  9. Wind shear coefficients and their effect on energy production

    International Nuclear Information System (INIS)

    Rehman, Shafiqur; Al-Abbadi, Naif M.

    2005-01-01

    This paper provides realistic values of wind shear coefficients calculated using measured values of wind speed at 20, 30 and 40 m above the ground for the first time in Saudi Arabia in particular and, to the best of the authors' knowledge, in the Gulf region in general. The paper also presents air density values calculated using the measured air temperature and surface pressure and the effects of wind shear factor on energy production from wind machines of different sizes. The measured data used in the study covered a period of almost three years between June 17, 1995 and December 1998. An overall mean value of wind shear coefficient of 0.194 can be used with confidence to calculate the wind speed at different heights if measured values are known at one height. The study showed that the wind shear coefficient is significantly influenced by seasonal and diurnal changes. Hence, for precise estimations of wind speed at a height, both monthly or seasonal and hourly or night time and day time average values of wind shear coefficient must be used. It is suggested that the wind shear coefficients must be calculated either (i) using long term average values of wind speed at different heights or (ii) using those half hourly mean values of wind speed for which the wind shear coefficient lies in the range 0 and 0.51. The air density, calculated using measured temperature and pressure was found to be 1.18 kg/m 3 . The air density values were also found to vary with the season of the year and hour of the day, and hence, care must be taken when precise calculations are to be made. The air density values, as shown in this paper, have no significant variation with height. The energy production analysis showed that the actual wind shear coefficient presented in this paper produced 6% more energy compared to that obtained using the 1/7 power law. Similarly, higher plant capacity factors were obtained with the wind shear factor of 0.194 compared to that with 0.143

  10. 242mAm Fueled Nuclear Battery

    International Nuclear Information System (INIS)

    Yigal Ronen, Y.; Hatav, A.; Hazenshprung, N.

    2004-01-01

    A nuclear battery based on a direct energy conversion of the fission products is presented. The principal behind direct-charging or direct-conversion [1] is based on the direct conversion of fission product energy into electrical energy, using a high voltage potential. The kinetic energy of the fission products is thus converted to potential energy and the charges collected in the conductive electrodes create an electrical current. High-power nuclear batteries are important due to the fact that they have almost no moving parts. As a result, maintenance problems (especially important in outer space) are considerably reduced. Such energy conversion is possible by using a nuclear reactor with ultra-thin fuel elements of 0.2 m of 242m Am. The amount of nuclear fuel is 376g and the dimensions of the battery are 2.4*2.4*2.4m (including the vacuum spacing), with a BeO moderator and Be electrodes. The total power of the reactor is 10.6 MW and the electrical power is 0.672 MW. The reactor is composed of 242m Am as a nuclear fuel with a thickness of 0.2μm and a moderator of 4 cm of BeO and two 0.5 cm thickness electrodes of Be, as presented in Fig. 1. The moderator-to-fuel-volume ratio is V m /V f = 250000. The infinite multiplication factor for this design is [2] k ∞ = 1.8

  11. Cyclotron absorption and emission in mode conversion layers emdash a new paradigm

    International Nuclear Information System (INIS)

    Swanson, D.G.

    1995-01-01

    When the analysis of absorption with mode conversion effects included began to mature in recent years, the study of the corresponding effects on emission began and has led to some surprising results. The classical expressions for cyclotron or synchrotron emission from a harmonic resonance were originally derived from models that did not include mode conversion or its attendant reflection, and classical expressions for the optical depth and opacity were obtained. When mode conversion was included, the principal surprise was that the transmission coefficient, which was understood as being due to absorption, is totally independent of absorption and due exclusively to tunneling. The other surprise from the mode conversion analysis is that the observed emission arises from two distinct sources, one direct and one from an indirect Bernstein wave source which is partially converted in the cyclotron layer to outgoing electromagnetic waves, with the net result that mode conversion cancels out for the electron case, but not for ions. The only corrections to electron cyclotron emission are then due to reflection effects, and these have been shown to be small for many laboratory plasmas, leading to the validation of the classical formula for these cases, but via an entirely new paradigm in its interpretation. This review includes a summary of the absorption process for both electron and ion cyclotron harmonics, and reviews carefully the emission physics, including both potential error estimates and a discussion of the emission source distribution in space

  12. On the Fetch Dependent Drag Coefficient over Coastal and Inland Seas

    DEFF Research Database (Denmark)

    Geernaert, G. L.; Smith, J. A.

    a maximum when the phase speed of the dominant wind wave has a value near 7 u*, where u* is the friction velocity. This corresponds to a maximum near 2 km fetch during moderate windspeed, and the maximum value of the drag coefficient corresponds to an increased fetch of 13 km for windspeeds of 20 m/sec. We......The drag coefficient has been postulated by many investigators to depend on fetch. For constant windspeed and stability, laboratory data generally show an increasing drag coefficient with fetch while field observations show a decreasing dependence. In this study, we show that if one combines...... the spectral form of the roughness length proposed by Kitaigorodskii with the JONSWAP wave spectrum and extrapolate to very short fetch, then the predicted drag coefficient exhibits a behaviour which coarsely reproduces field and laboratory observations. The results indicate that the drag coefficient exhibits...

  13. Study on heat transfer coefficients during cooling of PET bottles for food beverages

    Science.gov (United States)

    Liga, Antonio; Montesanto, Salvatore; Mannella, Gianluca A.; La Carrubba, Vincenzo; Brucato, Valerio; Cammalleri, Marco

    2016-08-01

    The heat transfer properties of different cooling systems dealing with Poly-Ethylene-Terephthalate (PET) bottles were investigated. The heat transfer coefficient (Ug) was measured in various fluid dynamic conditions. Cooling media were either air or water. It was shown that heat transfer coefficients are strongly affected by fluid dynamics conditions, and range from 10 W/m2 K to nearly 400 W/m2 K. PET bottle thickness effect on Ug was shown to become relevant under faster fluid dynamics regimes.

  14. Estimating Seebeck Coefficient of a p-Type High Temperature Thermoelectric Material Using Bee Algorithm Multi-layer Perception

    Science.gov (United States)

    Uysal, Fatih; Kilinc, Enes; Kurt, Huseyin; Celik, Erdal; Dugenci, Muharrem; Sagiroglu, Selami

    2017-08-01

    Thermoelectric generators (TEGs) convert heat into electrical energy. These energy-conversion systems do not involve any moving parts and are made of thermoelectric (TE) elements connected electrically in a series and thermally in parallel; however, they are currently not suitable for use in regular operations due to their low efficiency levels. In order to produce high-efficiency TEGs, there is a need for highly heat-resistant thermoelectric materials (TEMs) with an improved figure of merit ( ZT). Production and test methods used for TEMs today are highly expensive. This study attempts to estimate the Seebeck coefficient of TEMs by using the values of existing materials in the literature. The estimation is made within an artificial neural network (ANN) based on the amount of doping and production methods. Results of the estimations show that the Seebeck coefficient can approximate the real values with an average accuracy of 94.4%. In addition, ANN has detected that any change in production methods is followed by a change in the Seebeck coefficient.

  15. Coefficient estimates of negative powers and inverse coefficients for ...

    Indian Academy of Sciences (India)

    and the inequality is sharp for the inverse of the Koebe function k(z) = z/(1 − z)2. An alternative approach to the inverse coefficient problem for functions in the class S has been investigated by Schaeffer and Spencer [27] and FitzGerald [6]. Although, the inverse coefficient problem for the class S has been completely solved ...

  16. Prediction of Sliding Friction Coefficient Based on a Novel Hybrid Molecular-Mechanical Model.

    Science.gov (United States)

    Zhang, Xiaogang; Zhang, Yali; Wang, Jianmei; Sheng, Chenxing; Li, Zhixiong

    2018-08-01

    Sliding friction is a complex phenomenon which arises from the mechanical and molecular interactions of asperities when examined in a microscale. To reveal and further understand the effects of micro scaled mechanical and molecular components of friction coefficient on overall frictional behavior, a hybrid molecular-mechanical model is developed to investigate the effects of main factors, including different loads and surface roughness values, on the sliding friction coefficient in a boundary lubrication condition. Numerical modelling was conducted using a deterministic contact model and based on the molecular-mechanical theory of friction. In the contact model, with given external loads and surface topographies, the pressure distribution, real contact area, and elastic/plastic deformation of each single asperity contact were calculated. Then asperity friction coefficient was predicted by the sum of mechanical and molecular components of friction coefficient. The mechanical component was mainly determined by the contact width and elastic/plastic deformation, and the molecular component was estimated as a function of the contact area and interfacial shear stress. Numerical results were compared with experimental results and a good agreement was obtained. The model was then used to predict friction coefficients in different operating and surface conditions. Numerical results explain why applied load has a minimum effect on the friction coefficients. They also provide insight into the effect of surface roughness on the mechanical and molecular components of friction coefficients. It is revealed that the mechanical component dominates the friction coefficient when the surface roughness is large (Rq > 0.2 μm), while the friction coefficient is mainly determined by the molecular component when the surface is relatively smooth (Rq < 0.2 μm). Furthermore, optimal roughness values for minimizing the friction coefficient are recommended.

  17. Temperature dependence of He(2 3PJ) reactions: Collision-induced mixing and conversion to He2( 3Πg) molecules

    International Nuclear Information System (INIS)

    Zhao, X.; Soletsky, P.A.; Bryan, W.H.; Dunning, F.B.; Walters, G.K.

    1993-01-01

    The rate coefficients for mixing between He(2 3 P J, MJ) levels during collisions with ground-state helium atoms and for conversion of He(2 3 P J ) atoms to He 2 (b 3 Π g ) molecules via three-body reactions in helium gas have been investigated over the temperature range 1.6--300 K. The measured rate coefficients for collisionally induced P-state mixing decrease slowly with decreasing temperature, from (1.8±0.5)x10 -9 cm 3 s -1 at 300 K to (4.5±0.5)x10 -10 cm 3 s -1 at 4.2 K. The rate coefficients for the production of He 2 (b 3 Π g ) molecules via three-body reactions are observed to increase with decreasing temperature and are described by the relation k P congruent(2.5+267T -1 )x10 -32 cm 6 s -1 . This behavior, which is very different from that noted in earlier studies of the conversion of He(2 3 S 1 ) atoms to He 2 (a 3 Σ u + ) molecules through three-body reactions, suggests that the reaction is not thermally activated

  18. Estimates of external dose-rate conversion factors and internal dose conversion factors for selected radionuclides released from fusion facilities

    Energy Technology Data Exchange (ETDEWEB)

    Homma, Toshimitsu; Togawa, Orihiko [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-11-01

    This report provides a tabulation of both external dose-rate conversion factors and internal dose conversion factors using radioactive decay data in the updated Evaluated Nuclear Structure Data File (ENSDF) for selected 26 radionuclides and all their daughter radionuclides of potential importance in safety assessments of fusion facilities. The external dose-rate conversion factors for 21 target organs are tabulated for three exposure modes that are immersion in contaminated air, irradiation at a height of 1 m above a contaminated ground surface and immersion contaminated water. For internal exposure, committed dose equivalents, based on the methodology of ICRP Publication 30, in the same target organs per intake of unit activity are given for the inhalation and ingestion exposure pathways. The data presented here is intended to be generally used for safety assessments of fusion reactors. Comparisons of external effective dose-rate conversion factors and committed effective dose equivalents are made with the previous data from the independent data bases to provide quality assurance on our calculated results. There is generally good agreement among data from the independent data bases. The differences in the values of both effective dose-rate and dose conversion factors appeared are primarily due to differences in calculational methodology, the use of different radioactive decay data, and compilation errors. (author)

  19. DOSE COEFFICIENTS FOR LIVER CHEMOEMBOLISATION PROCEDURES USING MONTE CARLO CODE.

    Science.gov (United States)

    Karavasilis, E; Dimitriadis, A; Gonis, H; Pappas, P; Georgiou, E; Yakoumakis, E

    2016-12-01

    The aim of the present study is the estimation of radiation burden during liver chemoembolisation procedures. Organ dose and effective dose conversion factors, normalised to dose-area product (DAP), were estimated for chemoembolisation procedures using a Monte Carlo transport code in conjunction with an adult mathematical phantom. Exposure data from 32 patients were used to determine the exposure projections for the simulations. Equivalent organ (H T ) and effective (E) doses were estimated using individual DAP values. The organs receiving the highest amount of doses during these exams were lumbar spine, liver and kidneys. The mean effective dose conversion factor was 1.4 Sv Gy -1 m -2 Dose conversion factors can be useful for patient-specific radiation burden during chemoembolisation procedures. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Evaporation Kinetics of Polyol Droplets: Determination of Evaporation Coefficients and Diffusion Constants

    Science.gov (United States)

    Su, Yong-Yang; Marsh, Aleksandra; Haddrell, Allen E.; Li, Zhi-Ming; Reid, Jonathan P.

    2017-11-01

    In order to quantify the kinetics of mass transfer between the gas and condensed phases in aerosol, physicochemical properties of the gas and condensed phases and kinetic parameters (mass/thermal accommodation coefficients) are crucial for estimating mass fluxes over a wide size range from the free molecule to continuum regimes. In this study, we report measurements of the evaporation kinetics of droplets of 1-butanol, ethylene glycol (EG), diethylene glycol (DEG), and glycerol under well-controlled conditions (gas flow rates and temperature) using the previously developed cylindrical electrode electrodynamic balance technique. Measurements are compared with a model that captures the heat and mass transfer occurring at the evaporating droplet surface. The aim of these measurements is to clarify the discrepancy in the reported values of mass accommodation coefficientM, equals to evaporation coefficient based on microscopic reversibility) for 1-butanol, EG, and DEG and improve the accuracy of the value of the diffusion coefficient for glycerol in gaseous nitrogen. The uncertainties in the thermophysical and experimental parameters are carefully assessed, the literature values of the vapor pressures of these components are evaluated, and the plausible ranges of the evaporation coefficients for 1-butanol, EG, and DEG as well as uncertainty in diffusion coefficient for glycerol are reported. Results show that αM should be greater than 0.4, 0.2, and 0.4 for EG, DEG, and 1-butanol, respectively. The refined values are helpful for accurate prediction of the evaporation/condensation rates.

  1. Determination of drying kinetics and convective heat transfer coefficients of ginger slices

    Science.gov (United States)

    Akpinar, Ebru Kavak; Toraman, Seda

    2016-10-01

    In the present work, the effects of some parametric values on convective heat transfer coefficients and the thin layer drying process of ginger slices were investigated. Drying was done in the laboratory by using cyclone type convective dryer. The drying air temperature was varied as 40, 50, 60 and 70 °C and the air velocity is 0.8, 1.5 and 3 m/s. All drying experiments had only falling rate period. The drying data were fitted to the twelve mathematical models and performance of these models was investigated by comparing the determination of coefficient ( R 2), reduced Chi-square ( χ 2) and root mean square error between the observed and predicted moisture ratios. The effective moisture diffusivity and activation energy were calculated using an infinite series solution of Fick's diffusion equation. The average effective moisture diffusivity values and activation energy values varied from 2.807 × 10-10 to 6.977 × 10-10 m2/s and 19.313-22.722 kJ/mol over the drying air temperature and velocity range, respectively. Experimental data was used to evaluate the values of constants in Nusselt number expression by using linear regression analysis and consequently, convective heat transfer coefficients were determined in forced convection mode. Convective heat transfer coefficient of ginger slices showed changes in ranges 0.33-2.11 W/m2 °C.

  2. Improvement of skeleton conversion in ICRP reference phantom conversion project

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhao Jun; Yeom, Yeon Soo; Thang, Nguyen Tat; Kim, Han Sung; Han, Min Cheol; Kim, Chan Hyeong [Dept. of Nuclear Engineering, Hanyang University, Seoul (Korea, Republic of); Kim, Seong Hoon [Dept. of Radiation Oncology, College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    2014-11-15

    In the previous skeleton conversion, most bones were directly converted from the ICRP voxel phantoms by using the 3D rendering method whereas several complex-shape bones (cranium, ribs, spines, feet, and hands) were not able to be directly converted. We alternatively employed the corresponding well-defined polygonal models and attempted to adjust them to match the voxel models. However, this approach was unsatisfactory. The shapes of the alternative models were significantly different from those of the voxel models, making it virtually impossible to exactly match the voxel models as shown in Fig. 3 (left). In order to overcome the difficulty in the complex bone conversion, the present study developed a new conversion method and converted these complex bones voxel models of the ICRP male phantom to polygonal models. The present study developed the new conversion method and successfully improved polygonal models for cranium, ribs, and spines for the ICRP male phantom. The new conversion method will be also applied to the complex bone conversion for the ICRP female phantom as well as other complex organ conversion in the future.

  3. Improvement of skeleton conversion in ICRP reference phantom conversion project

    International Nuclear Information System (INIS)

    Wang, Zhao Jun; Yeom, Yeon Soo; Thang, Nguyen Tat; Kim, Han Sung; Han, Min Cheol; Kim, Chan Hyeong; Kim, Seong Hoon

    2014-01-01

    In the previous skeleton conversion, most bones were directly converted from the ICRP voxel phantoms by using the 3D rendering method whereas several complex-shape bones (cranium, ribs, spines, feet, and hands) were not able to be directly converted. We alternatively employed the corresponding well-defined polygonal models and attempted to adjust them to match the voxel models. However, this approach was unsatisfactory. The shapes of the alternative models were significantly different from those of the voxel models, making it virtually impossible to exactly match the voxel models as shown in Fig. 3 (left). In order to overcome the difficulty in the complex bone conversion, the present study developed a new conversion method and converted these complex bones voxel models of the ICRP male phantom to polygonal models. The present study developed the new conversion method and successfully improved polygonal models for cranium, ribs, and spines for the ICRP male phantom. The new conversion method will be also applied to the complex bone conversion for the ICRP female phantom as well as other complex organ conversion in the future

  4. Interference effects in Moessbauer spectra of M1-transitions

    International Nuclear Information System (INIS)

    Peregudov, V.N.

    1980-01-01

    The purpose of the study is the calculation of interference effects in Moessbauer spectra of the (γ, e) reaction. Two channels of the inelastic (γ, e) reaction are considered: resonance gamma radiation absorption by nucleus accompanied by internal conversion and photo absorption by atomic electrons. The case of M1 nuclear transition multipolarity is considered. The expression for angular dependence coefficients of interference member is obtained. General expression for (γ, e) reaction cross section is obtained in a long-wave approximation for the case when the specimen is placed in longitudinal magnetic field involving superfine nuclear level splitting. The results of disperse amplitudes calculation for 93 Kr, 119 Sn, 129 I, 149 Sm, 151 Eu, 169 Tm, 183 W, 193 Ir, 197 Au nuclei are verified. The calculations show that maximum interference effect in the (γ, e) reaction should be expected for 169 Tm isotope [ru

  5. Novel high efficient speed sensorless controller for maximum power extraction from wind energy conversion systems

    International Nuclear Information System (INIS)

    Fathabadi, Hassan

    2016-01-01

    Highlights: • Novel sensorless MPPT technique without drawbacks of other sensor/sensorless methods. • Tracking the actual MPP of WECSs, no tracking the MPP of their wind turbines. • Actually extracting the highest output power from WECSs. • Novel MPPT technique having the MPPT efficiency more than 98.5% for WECSs. • Novel MPPT technique having short convergence time for WECSs. - Abstract: In this study, a novel high accurate sensorless maximum power point tracking (MPPT) method is proposed. The technique tracks the actual maximum power point of a wind energy conversion system (WECS) at which maximum output power is extracted from the system, not the maximum power point of its wind turbine at which maximum mechanical power is obtained from the turbine, so it actually extracts the highest output power from the system. The technique only uses input voltage and current of the converter used in the system, and neither needs any speed sensors (anemometer and tachometer) nor has the drawbacks of other sensor/sensorless based MPPT methods. The technique has been implemented as a MPPT controller by constructing a WECS. Theoretical results, the technique performance, and its advantages are validated by presenting real experimental results. The real static-dynamic response of the MPPT controller is experimentally obtained that verifies the proposed MPPT technique high accurately extracts the highest instant power from wind energy conversion systems with the MPPT efficiency of more than 98.5% and a short convergence time that is only 25 s for the constructed system having a total inertia and friction coefficient of 3.93 kg m 2 and 0.014 N m s, respectively.

  6. Conversations about mental states and theory of mind development during middle childhood: A training study.

    Science.gov (United States)

    Bianco, Federica; Lecce, Serena; Banerjee, Robin

    2016-09-01

    Despite 30years of productive research on theory of mind (ToM), we still know relatively little about variables that influence ToM development during middle childhood. Recent experimental studies have shown that conversations about the mind affect ToM abilities, but they have not explored the mechanisms underlying this developmental effect. In the current study, we examined two potential mechanisms through which conversations about mental states are likely to influence ToM: an increased frequency of references to mental states when explaining behavior and an increased accuracy of mental-state attributions. To this aim, we conducted a training study in which 101 children were assigned to either an intervention condition or a control condition. The conversation-based intervention was made up of four sessions scheduled over 2weeks. Children completed a battery of assessments before and after the intervention as well as 2months later. The groups were equivalent at Time 1 (T1) for age, family affluence, vocabulary, and executive functions. The ToM group showed an improvement in ToM skills (as evaluated on both the practiced tasks and a transfer task). Mediation analyses demonstrated that the accuracy of mental-state attributions, but not the mere frequency of mental-state references, mediated the positive effect of conversations about the mind on ToM development. Our results indicate that conversational experience can enhance mental-state reasoning not by simply drawing children's attention to mental states but rather by scaffolding a mature understanding of social situations. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Assessment of dose conversion factors in a generic biosphere of a Korea HLW repository

    International Nuclear Information System (INIS)

    Hwang, Y. S.; Park, J. B.; Kang, C. H.

    2002-01-01

    Radioactive species released from a waste repository migrate through engineered and natural barriers and eventually reach the biosphere. Once entered the biosphere, contaminants transport various exposure pathways and finally reach a human. In this study the full RES matrix explaining the key compartments in the biosphere and their interactions is introduced considering the characteristics of the Korean biosphere. Then the three exposure groups are identified based on the compartments of interest. The full exposure pathways and corresponding mathematical expression for mass transfer coefficients and etc are developed and applied to assess the dose conversion factors of nuclides for a specific exposure group. Dose conversion factors assessed in this study will be used for total system performance assessment of a potential Korean HLW repository

  8. Sorption Coefficients for Iodine, Silver, and Cesium on Dust Particles

    International Nuclear Information System (INIS)

    Stempniewicz, M.M.; Goede, P.

    2014-01-01

    This paper describes the work performed to find relevant experimental data and find the sorption coefficients that represent well the available data for cesium, iodine, and silver on dust particles. The purpose of this work is to generate a set of coefficients that may be recommended for the computer code users. The work was performed using the computer code SPECTRA. Calculations were performed for the following data: • I-131 on AVR dust; • Ag-110m on AVR dust; • Cs-13 and Cs-137 on AVR dust. Available data was matched using the SPECTRA Sorption Model. S = A(T) · C_V-B(T) · C_d. The results are summarized as follows: • The available data can be correlated. The data scatter is about 4 orders of magnitude. Therefore the coefficients of the Langmuir isotherms vary by 4 orders of magnitude. • Sorption rates are higher at low temperatures and lower at high temperatures. This tendency has been observed in the data compiled at Oak Ridge. It is therefore surmised that the highest value of the sorption coefficients are appropriate for the low temperatures and the lowest value of the sorption coefficients are appropriate for the high temperatures. The recommended sorption coefficients are presented in this paper. • The present set of coefficients is very rough and should be a subject for future verification against experimental data. (author)

  9. Coefficient Alpha: A Reliability Coefficient for the 21st Century?

    Science.gov (United States)

    Yang, Yanyun; Green, Samuel B.

    2011-01-01

    Coefficient alpha is almost universally applied to assess reliability of scales in psychology. We argue that researchers should consider alternatives to coefficient alpha. Our preference is for structural equation modeling (SEM) estimates of reliability because they are informative and allow for an empirical evaluation of the assumptions…

  10. Numerical study of the particle transport in fast neutron detectors with conversion layer

    International Nuclear Information System (INIS)

    Sedlackova, K.; Zatko, B.; Necas, V.

    2012-01-01

    This paper deals with fast neutron and recoil proton transport simulation using statistical analysis of Monte Carlo radiation transport code (MCNPX). Its possibilities in the detector design and optimization are presented. MCNPX proved as a very advantageous self-contained simulation program for fast neutron and secondary proton tracking. Simulations of respective particle transport through conversion layer of HDPE and further in the active volume of detector let us to follow important characteristics as neutron/proton flux density, reaction rate of elastic scattering on hydrogen nuclei and deposited energy as well as their dependencies on incident neutron energy and conversion layer/active region thickness. The efficiency of neutrons to protons conversion has been calculated and its maximum was reached for 500 μm thick conversion layer. The minimum active region thickness has been estimated to be about 300 μm.(authors)

  11. Microstructure and corrosion resistance of Ce–V conversion coating on AZ31 magnesium alloy

    International Nuclear Information System (INIS)

    Jiang, Xiao; Guo, Ruiguang; Jiang, Shuqin

    2015-01-01

    Highlights: • Through simple chemical conversion process, a Ce–V conversion coating is prepared on AZ31 magnesium alloy. The coating (∼2 μm thick) has a duplex structure and is composed of Mg, Al, Ce, V and O in the outer layer and Mg, Al, V, F and O in the inner layer. • The Ce–V conversion coating can increase the E corr by 157 mV and decrease the i corr by 80 times compared to AZ31 magnesium alloy substrate. Moreover, the performance of the Ce–V conversion coating excels the chromate conversion coating on AZ31 magnesium alloy. • The EIS results of Ce–V conversion coating indicate an increase of 10× in the corrosion resistance and a delay in the corrosion process kinetics compared to uncoated AZ31 magnesium alloy in 3.5 wt.% NaCl solution. • The ball cratering is a simple and effective technique of thickness measurement for chemical conversion coating. - Abstract: A Ce–V conversion coating was developed to improve the corrosion resistance of AZ31 magnesium alloy. Scanning electronic microscope (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectrometer (XPS), grazing incidence X-ray diffraction (GIXRD) and the ball cratering test were adopted to study the morphology, chemical composition, structure and thickness of the coating. The coating has duplex structure with network and its thickness is about 2 μm. The coating contains high contents of Ce and V, which exhibits amorphous structure. Potentiodynamic polarization shows the coating can increase the corrosion potential and reduce the corrosion current density of AZ31 magnesium alloy. Moreover, the electrochemical impedance spectra exhibit the coating significantly improves the corrosion resistance of AZ31 magnesium alloy. Results indicate that the Ce–V conversion coating can provide effective protection to AZ31 magnesium alloy

  12. Microstructure and corrosion resistance of Ce–V conversion coating on AZ31 magnesium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xiao, E-mail: xiaoxiao217@126.com; Guo, Ruiguang; Jiang, Shuqin

    2015-06-30

    Highlights: • Through simple chemical conversion process, a Ce–V conversion coating is prepared on AZ31 magnesium alloy. The coating (∼2 μm thick) has a duplex structure and is composed of Mg, Al, Ce, V and O in the outer layer and Mg, Al, V, F and O in the inner layer. • The Ce–V conversion coating can increase the E{sub corr} by 157 mV and decrease the i{sub corr} by 80 times compared to AZ31 magnesium alloy substrate. Moreover, the performance of the Ce–V conversion coating excels the chromate conversion coating on AZ31 magnesium alloy. • The EIS results of Ce–V conversion coating indicate an increase of 10× in the corrosion resistance and a delay in the corrosion process kinetics compared to uncoated AZ31 magnesium alloy in 3.5 wt.% NaCl solution. • The ball cratering is a simple and effective technique of thickness measurement for chemical conversion coating. - Abstract: A Ce–V conversion coating was developed to improve the corrosion resistance of AZ31 magnesium alloy. Scanning electronic microscope (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectrometer (XPS), grazing incidence X-ray diffraction (GIXRD) and the ball cratering test were adopted to study the morphology, chemical composition, structure and thickness of the coating. The coating has duplex structure with network and its thickness is about 2 μm. The coating contains high contents of Ce and V, which exhibits amorphous structure. Potentiodynamic polarization shows the coating can increase the corrosion potential and reduce the corrosion current density of AZ31 magnesium alloy. Moreover, the electrochemical impedance spectra exhibit the coating significantly improves the corrosion resistance of AZ31 magnesium alloy. Results indicate that the Ce–V conversion coating can provide effective protection to AZ31 magnesium alloy.

  13. Discourse analysis: Conversational analysis of the internal conversation in Oracle Corporation Malaysia

    Directory of Open Access Journals (Sweden)

    Marwa Marwa

    2017-07-01

    Full Text Available This study highlights the internal conversation which takes place in Oracle CorporationMalaysia. Through the study, it will be shown how conversational analysis is used toanalyze the transcription of a telephone conversation between Oracle staffs. The analysisof the transcriptions will apply a few basic concepts of conversational analysis; turntakingorganization, and the adjacency pair. The objective of the study is to find out howthe internal conversations takes place by focusing on the conversation itself, that is, theconversational structures spontaneously produced by people during talk ranging fromturn-taking strategies, how topics are introduced, conversation closings and so on. Bylooking in detail at such talk, we can gain a detailed understanding of how the staffs seethemselves in relation to the company that influence their daily lives.Keywords: conversational analysis, turn-taking, adjacency pairs

  14. Derivation of pulse height to exposure rate conversion functions for aerial radiological surveys

    International Nuclear Information System (INIS)

    Artuso, J.F.

    1985-01-01

    A method is described for deriving conversion functions that can be used to convert pulse height spectra taken at altitude to the exposure rate at the 1-m level. An integral equation is set up which involves the integration of a calculated pulse height spectrum multiplied by an unknown conversion function and then set equal to the exposure rate at ground level. This equation is then solved for the conversion function by assuming as a solution a three-term polynomial. Conversion functions have been derived for various source distributions, including surface, uniform, and exponentially distributed sources. These conversion functions are independent of source energy, which means that a conversion can be made without any knowledge of the isotopic content of the source. In the case of a uniform distribution, these conversion functions provide conversions that agree to within 10% with ground truth measurements

  15. Investigation of the Buckling-Reactivity Conversion Coefficient using SRAC and MVP codes for UO2 Lattices in TCA experiments

    International Nuclear Information System (INIS)

    Le Dai Dien

    2008-01-01

    Benchmark experiments for International Reactor Physics Benchmark Experiments (IRPhE) Project carried out at TCA, the temperature effects on reactivity were studied for light water moderated and reflected UO 2 cores with/without soluble poisons. The buckling coefficient method using the measured critical water levels was proposed by Suzaki et al. The temperature dependence of buckling coefficient of reactivity and its variance by the core configurations of the benchmark experiments was investigated using SRAC and MVP calculations. From the calculations by SRAC as well as by MVP it is seen that the K-value can be taken as an average value only for each core with temperature changes which are considered as perturbation parameter. The difference between our calculations and benchmark results which uses constant K-value for all cores proves that the results depend on K-value and it play important role in defining reactivity effect using the water level worth method. (author)

  16. Condensation coefficient of water in a weak condensation state

    International Nuclear Information System (INIS)

    Kobayashi, Kazumichi; Watanabe, Shunsuke; Yamano, Daigo; Yano, Takeru; Fujikawa, Shigeo

    2008-01-01

    The condensation coefficient of water at a vapor-liquid interface is determined by combining shock tube experiments and numerical simulations of the Gaussian-BGK Boltzmann equation. The time evolution in thickness of a liquid film, which is formed on the shock tube endwall behind the shock wave reflected at the endwall, is measured with an optical interferometer consisting of the physical beam and the reference one. The reference beam is utilized to eliminate systematic noises from the physical beam. The growth rate of the film is evaluated from the measured time evolution and it is incorporated into the kinetic boundary condition for the Boltzmann equation. From a numerical simulation using the boundary condition, the condensation coefficient of water is uniquely deduced. The results show that, in a condition of weak condensation near a vapor-liquid equilibrium state, the condensation coefficient of water is almost equal to the evaporation coefficient estimated by molecular dynamics simulations near a vapor-liquid equilibrium state and it decreases as the system becomes a nonequilibrium state. The condensation coefficient of water is nearly identical with that of methanol [Mikami, S., Kobayashi, K., Ota, T., Fujikawa, S., Yano, T., Ichijo, M., 2006. Molecular gas dynamics approaches to interfacial phenomena accompanied with condensation. Exp. Therm. Fluid Sci. 30, 795-800].

  17. Condensation coefficient of water in a weak condensation state

    Science.gov (United States)

    Kobayashi, Kazumichi; Watanabe, Shunsuke; Yamano, Daigo; Yano, Takeru; Fujikawa, Shigeo

    2008-07-01

    The condensation coefficient of water at a vapor-liquid interface is determined by combining shock tube experiments and numerical simulations of the Gaussian-BGK Boltzmann equation. The time evolution in thickness of a liquid film, which is formed on the shock tube endwall behind the shock wave reflected at the endwall, is measured with an optical interferometer consisting of the physical beam and the reference one. The reference beam is utilized to eliminate systematic noises from the physical beam. The growth rate of the film is evaluated from the measured time evolution and it is incorporated into the kinetic boundary condition for the Boltzmann equation. From a numerical simulation using the boundary condition, the condensation coefficient of water is uniquely deduced. The results show that, in a condition of weak condensation near a vapor-liquid equilibrium state, the condensation coefficient of water is almost equal to the evaporation coefficient estimated by molecular dynamics simulations near a vapor-liquid equilibrium state and it decreases as the system becomes a nonequilibrium state. The condensation coefficient of water is nearly identical with that of methanol [Mikami, S., Kobayashi, K., Ota, T., Fujikawa, S., Yano, T., Ichijo, M., 2006. Molecular gas dynamics approaches to interfacial phenomena accompanied with condensation. Exp. Therm. Fluid Sci. 30, 795-800].

  18. Impact of improved momentum transfer coefficients on the dynamics and thermodynamics of the north Indian Ocean

    Science.gov (United States)

    Parekh, Anant; Gnanaseelan, C.; Jayakumar, A.

    2011-01-01

    Long time series of in situ observations from the north Indian Ocean are used to compute the momentum transfer coefficients over the north Indian Ocean. The transfer coefficients behave nonlinearly for low winds (<4 m/s), when most of the known empirical relations assume linear relations. Impact of momentum transfer coefficients on the upper ocean parameters is studied using an ocean general circulation model. The model experiments revealed that the Arabian Sea and Equatorial Indian Ocean are more sensitive to the momentum transfer coefficients than the Bay of Bengal and south Indian Ocean. The impact of momentum transfer coefficients on sea surface temperature is up to 0.3°C-0.4°C, on mixed layer depth is up to 10 m, and on thermocline depth is up to 15 m. Furthermore, the impact on the zonal current is maximum over the equatorial Indian Ocean (i.e., about 0.12 m/s in May and 0.15 m/s in October; both May and October are the period of Wyrtki jets and the difference in current has potential impact on the seasonal mass transport). The Sverdrup transport has maximum impact in the Bay of Bengal (3 to 4 Sv in August), whereas the Ekman transport has maximum impact in the Arabian Sea (4 Sv during May to July). These highlight the potential impact of accurate momentum forcing on the results from current ocean models.

  19. Effect of the coefficient of friction of a running surface on sprint time in a sled-towing exercise.

    Science.gov (United States)

    Linthorne, Nicholas P; Cooper, James E

    2013-06-01

    This study investigated the effect of the coefficient of friction of a running surface on an athlete's sprint time in a sled-towing exercise. The coefficients of friction of four common sports surfaces (a synthetic athletics track, a natural grass rugby pitch, a 3G football pitch, and an artificial grass hockey pitch) were determined from the force required to tow a weighted sled across the surface. Timing gates were then used to measure the 30-m sprint time for six rugby players when towing a sled of varied weight across the surfaces. There were substantial differences between the coefficients of friction for the four surfaces (micro = 0.21-0.58), and in the sled-towing exercise the athlete's 30-m sprint time increased linearly with increasing sled weight. The hockey pitch (which had the lowest coefficient of friction) produced a substantially lower rate of increase in 30-m sprint time, but there were no significant differences between the other surfaces. The results indicate that although an athlete's sprint time in a sled-towing exercise is affected by the coefficient offriction of the surface, the relationship relationship between the athlete's rate of increase in 30-m sprint time and the coefficient of friction is more complex than expected.

  20. Recurrence relations between transformation coefficients of hyperspherical harmonics and their application to Moshinsky coefficients

    International Nuclear Information System (INIS)

    Raynal, J.

    1976-01-01

    Closed formulae and recurrence relations for the transformation of a two-body harmonic oscillator wave function to the hyperspherical formalism are given. With them Moshinsky or Smirnov coefficients are obtained from the transformation coefficients of hyperspheric harmonics. For these coefficients the diagonalization method of Talman and Lande reduces to simple recurrence relations which can be used directly to compute them. New closed formulae for these coefficients are also derived: they are needed to compute the two simplest coefficients which determine the sign for the recurrence relation. (Auth.)

  1. Interpretation of Nonlinear Well Loss Coefficients for Rorabaugh (1953) Method.

    Science.gov (United States)

    Kurtulus, B.; Yaylım, T. N.; Avşar

    2016-12-01

    Step drawdown test (SDT) are essential for hydrogeologist to determine aquifer loss and well loss parameters. In a SDT, different series of constant-discharges with incremental rates are conducted to obtain incremental drawdown into the pumping well. Pumping well efficiency (if the well is properly developed and designed), aquifer characteristics (transmissivity, storativity) and discharge-drawdown relationship can be derived from SDT. The well loss parameter directly associate with the well efficiency. The main problem is to determine the correct well loss parameter in order to estimate aquifer characteristics. Walton (1962) stated that the interpretation of the well efficiency is possible to determine the nonlinear head loss coefficient (C) with p equals to 2 and Walton (1962) presented a criteria that suggested the following terms: If C is less than 1800 m2/s5, the is properly developed and designed, If C is ranged from 1800 m2/s5 to 3600 m2/s5, the well has a mild deterioration, If C is greater than 3600 m2/s5, the well has a severe clogging. Until now, several well-known computer techniques such as Aqutesolv, AquiferWin32 , AquifertestPro can be found in the literature to evaluate well efficiency when exponential parameter (p) equals to 2. However, there exist a lack of information to evaluate well efficiency for different number of exponential parameter (p). Strategic Water Storage & Recovery (SWSR) Project in Liwa, Abu Dhabi is the leading and unique hydrogeology project in the world because of its both financial and scientific dimension. A total of 315 recovery wells have been drilled in pursuance of the scope of the SWSR project. A Universal Well Efficiency Criteria (UWEC) is developed using 315 Step Drawdown Test (SDT). UWEC is defined for different number of head loss equation coefficients. The results reveal that there is a strong correlation between non-linear well loss coefficient (C) and exponential parameter (p) up to a coefficient of determination

  2. Measurement of Soret coefficients in a ternary mixture of toluene-methanol-cyclohexane in convection-free environment

    Science.gov (United States)

    Mialdun, A.; Ryzhkov, I.; Khlybov, O.; Lyubimova, T.; Shevtsova, V.

    2018-01-01

    We report on the measurement of Soret (ST) coefficients in the ternary system toluene (T)-methanol (M)-cyclohexane (Ch) onboard the International Space Station in the experiment selectable optical diagnostic instrument/DCMIX2 (Diffusion Coefficients Measurement in ternary mIXtures). Nine experiments were conducted in the range of mean temperatures between 298.15 K and 306.15 K in the mixture with composition 0.62 (T)-0.31 (M)-0.07 (Ch) in mass fractions. A linear dependence of the Soret coefficients on temperature was established for the ternary mixture. It has also been found that, over considered range of mean temperatures, the Soret coefficients of toluene are small and positive, while the Soret coefficients for methanol are negative and, at least, two times larger. The present work also presents a comprehensive study of possible methodologies to process raw data from the Soret experiment in ternary mixtures. All the experiments were processed by seven different schemes and two of them were identified as the most reliable. We also investigate the error propagation and explain the reasons for the discrepancy of the results obtained by different schemes.

  3. Factors determining conversion of laparoscopic to open cholecystectomy

    Directory of Open Access Journals (Sweden)

    Tapash Kumar Maitra

    2017-07-01

    Full Text Available Background and objectives:Laparoscopic cholecystectomy (LC has virtually replaced conventional open cholecystectomy (OC as the standard procedure of treatment for cholelithiasis and cholecystitis. However, OC sometimes becomes a necessity considering the feasibility and safety of the surgical procedure. But the factors that demand conversion from LC to OC differ widely. The present study aimed to determine the prevalence of conversion from LC to OC and to assess the causes of conversion and risk factors related to conversion. Methods: The study was conducted in a referral hospital – ‘Bangladesh Institute of Research and Rehabilitation in Diabetes, Endocrine and Metabolic Disorder (BIRDEM’ from September 2014 to September 2016. Cases of cholelithiasis with or without cholecystitis, and other gall bladder pathology were included in the study. A team of experienced surgeon performed LC of all selected cases. The causes of conversion to OC were systematically recorded by the surgical team and the risk factors (age, sex, obesity, history of previous abdominal surgery, gallbladder thickness related to conversion from LC to OC was investigated. Results: A total of 261 (M / F = 87 /174 patients were considered eligible for the study. The mean age of all patients was 43 (±1.75 years. For the male and female groups the mean ages were 44±1.9 and 42±1.6 years respectively. Of the total 261 cases, 210 (80.5% patients had cholelithiasis with chronic cholecystitis, 47 (18.0% had gallbladder stone plus acute cholecystitis and 4 (1.5% had gallbladder polyp. Open conversion was required in case of 19 patients. Thus, overall conversion rate was 7.3%. The common causes of conversion were a difficulty in defining Calot’s triangle (42.1%, b injury to cystic artery (21.1% and c injury to bile duct (15.8%. Both male and female had equal risk for conversion. The investigated risk factors like history of previous abdominal surgery, preoperative ERCP, acute

  4. Multilevel Preconditioners for Discontinuous Galerkin Approximations of Elliptic Problems with Jump Coefficients

    Science.gov (United States)

    2010-12-01

    discontinuous coefficients on geometrically nonconforming substructures. Technical Report Serie A 634, Instituto de Matematica Pura e Aplicada, Brazil, 2009...Instituto de Matematica Pura e Aplicada, Brazil, 2010. submitted. [41] M. Dryja, M. V. Sarkis, and O. B. Widlund. Multilevel Schwarz methods for

  5. Effect of design and operation parameters on heat transfer coefficient in condensers

    International Nuclear Information System (INIS)

    Eskin, N.; Arslan, G.; Balci, T.

    2009-01-01

    Accurate and optimum usage of energy sources is gaining importance all over the world due to the increase of energy need and limited energy sources. Increasing condenser efficiency, reduce both the dimensions and the material usage and also the investment cost of the devices. This can be maintained by increasing the heat transfer coefficient in condensers. Generally, tubes having plain inner surfaces are mounted horizontally in serpentine type condenser applications and due to the performance loss results from the congestion in serpentine connections, vertical tube mounting is not preferred. Due to the complexity of the two-phase flow, a single set of correlation for heat transfer cannot be used. Average and local heat transfer coefficient for condensers are determined. Moreover, for each experiments flow pattern is determined and the validity of the correlations are compared according to that flow pattern. In Table 2, some of the experiments for R134a are listed. Local heat transfer coefficient is also important for condenser design. As a result, to design effective condensers the accuracy of the correlations is very important. When all the experiments are taken into account, it is seen that deviation of the correlations differs according to the refrigerant type, tube dimensions, mass flux, saturation temperature and flow pattern. For high mass flux (>400 kg/m 2 s) Traviss (1973) correlation failed. For small diameters (<3.14 mm) Tandon (1985) correlation estimate the heat transfer coefficient with a high deviation. Most accurate results are obtained for Akers et al. (1959), M.M. Shah (1978), Cavallini and Zecchlin (1974), J.R. Thome - J. El Hajal - A. Cavallini (2003) correlations. For high mass flux and annular flow, M.M. Shah (1978) correlation estimates the heat transfer coefficient with high precision. However, as the tube diameter decrease, this deviation increases. For small tube diameter such as 0.691 mm Cavallini and Zecchlin (1974) gives the most

  6. Evaluation of convective heat transfer coefficient of various crops in cyclone type dryer

    International Nuclear Information System (INIS)

    Akpinar, E. Kavak

    2005-01-01

    In this paper, an attempt was made to evaluate the convective heat transfer coefficient during drying of various crops and to investigate the influences of drying air velocity and temperature on the convective heat transfer coefficient. Drying was conducted in a convective cyclone type dryer at drying air temperatures of 60, 70 and 80 deg. C and velocities of 1 and 1.5 m/s using rectangle shaped potato and apple slices (12.5 x 12.5 x 25 mm) and cylindrical shaped pumpkin slices (35 x 5 mm). The temperature changes of the dried crops and the temperature of the drying air were measured during the drying process. It was found that the values of convective heat transfer coefficient varied from crop to crop with a range 30.21406 and 20.65470 W/m 2 C for the crops studied, and it was observed that the convective heat transfer coefficient increased in large amounts with the increase of the drying air velocity but increased in small amounts with the rise of the drying air temperature

  7. Evaluation of convective heat transfer coefficient of various crops in cyclone type dryer

    Energy Technology Data Exchange (ETDEWEB)

    Akpinar, E. Kavak [Mechanical Engineering Department, Firat University, 23279 Elazig (Turkey)]. E-mail: eakpinar@firat.edu.tr

    2005-09-15

    In this paper, an attempt was made to evaluate the convective heat transfer coefficient during drying of various crops and to investigate the influences of drying air velocity and temperature on the convective heat transfer coefficient. Drying was conducted in a convective cyclone type dryer at drying air temperatures of 60, 70 and 80 deg. C and velocities of 1 and 1.5 m/s using rectangle shaped potato and apple slices (12.5 x 12.5 x 25 mm) and cylindrical shaped pumpkin slices (35 x 5 mm). The temperature changes of the dried crops and the temperature of the drying air were measured during the drying process. It was found that the values of convective heat transfer coefficient varied from crop to crop with a range 30.21406 and 20.65470 W/m{sup 2} C for the crops studied, and it was observed that the convective heat transfer coefficient increased in large amounts with the increase of the drying air velocity but increased in small amounts with the rise of the drying air temperature.

  8. Apparent partition coefficient in octanol-water and binding percentage to BSA of 153Sm(113,117Snm) complexes

    International Nuclear Information System (INIS)

    Yang Yuqing; Luo Shunzhong; Wang Guanquan; He Jiaheng; Bing Wenzeng; Pu Manfei; Wei Hongyuan; Wang Wenjin

    2004-01-01

    Apparent partition coefficient in octanol-water and binding percentage to BSA of 153 Sm-NTMP, 153 Sm-HEDTMP, 153 Sm-DCTMP, 153 Sm-EDTMP, 153 Sm-DTPMP, 113,117 Sn m -EDTMP, 113,117 Sn m -HEDTMP, 113,117 Sn m -DTPMP are measured. The results show that there is a linear relationship between the relative magnitude of the apparent partition coefficient in octanol-water and the relative magnitude of the binding percentage to BSA of these 153 Sm( 113,117 Sn m ) complexes. This linear relationship provides a new method for determination of the apparent partition coefficient in octanol-water of 153 Sm( 113,117 Sn m ) complexes of this kind. This linear relationship also implicates that hydrophobic force plays an important role in the binding of 153 Sm( 113,117 Sn m ) complexes to BSA

  9. Analytic expressions for mode conversion in a plasma with a parabolic density profile: Generalized results

    International Nuclear Information System (INIS)

    Hinkel-Lipsker, D.E.; Fried, B.D.; Morales, G.J.

    1993-01-01

    This study provides an analytic solution to the general problem of mode conversion in an unmagnetized plasma. Specifically, an electromagnetic wave of frequency ω propagating through a plasma with a parabolic density profile of scale length L p is examined. The mode conversion points are located a distance Δ 0 from the peak of the profile, where the electron plasma frequency ω p (z) matches the wave frequency ω. The corresponding reflection, transmission, and mode conversion coefficients are expressed analytically in terms of parabolic cylinder functions for all values of Δ 0 . The method of solution is based on a source approximation technique that is valid when the electromagnetic and electrostatic scale lengths are well separated. For large Δ 0 , i.e., (cL p /ω) 1/2 much-lt Δ 0 p , the appropriately scaled result [D. E. Hinkel-Lipsker et al., Phys. Fluids B 4, 559 (1992)] for a linear density profile is recovered as the parabolic cylinder functions asymptotically become Airy functions. When Δ 0 →0, the special case of conversion at the peak of the profile [D. E. Hinkel-Lipsker et al., Phys. Fluids B 4, 1772 (1992)] is obtained

  10. Parametric study of up-conversion efficiency in Er-doped ceria nanoparticles under 780 nm excitation

    International Nuclear Information System (INIS)

    Shehata, N.; Kandas, I.; Samir, E.; Meehan, K.; Aldacher, M.

    2016-01-01

    This paper presents a new parametric study of the optical up-conversion process in ceria nanoparticles doped with erbium (Er-CeO 2 NPs). Under 780 nm excitation, both the possible transitions that occur between Er 3+ ions and up-conversion rate model simulation are presented. Ceria nanoparticles (CeO 2 NPs) doped with erbium are experimentally synthesized using chemical precipitation technique with post-annealing up to 900 °C with different weight ratios of erbium dopant. We found that the synthesized nanoparticles can emit both green and red emissions under 780 nm laser excitation via two-photon absorption mechanism. Then, the quantum efficiencies of both colored emissions are theoretically investigated with different parameters related to the optical conversion process and the studied material. In addition, this work offer suggested ranges for the optimum values of the studied parameters which could improve the quantum yield efficiency. Einstein coefficients for erbium hosted in ceria are discussed in details using Judd–Ofelt analysis. This promising study could be helpful in improving the up-conversion efficiency of Er-ceria nanoparticles for applications such as bio-imaging and optical-based sensors.

  11. Effects of conversion of mangroves into gei wai ponds on sediment heavy metals accumulation in tidal flat estuary, South China

    Science.gov (United States)

    Li, R.; Qiu, G.; Chai, M.; Li, R.

    2017-12-01

    Gei wai ponds act as important component in mangrove ecosystem, but the conversion of mangroves into gei wai ponds and its ecological function on heavy metal accumulation is still not clear. The study quantified the sediment heavy metal concentration and speciation in gei wai pond, Avicennia marina marsh and mudflat in Futian mangrove wetlands, South China. The results showed that gei wai pond acidified the sediment and reduced its fertility due to reduced pH, electronic conductivity (EC) and total organic carbon (TOC) compared to A. marina marsh and mudflat. The concentrations of Cd, Cu, Zn and Pb at all depth in gei wai pond sediment were also lower than other sites, indicating reduced storage function on heavy metals. Multiple analysis implied that heavy metals in all sites could be attributed to anthropogenic sources, with Cr as natural and anthropogenic sources in gei wai pond. Gei wai pond sediment had lower heavy metal pollution based on multiple evaluation methods, including potential ecological risk coefficient (Eir), potential ecological risk index (RI), geo-accumulation index (Igeo), mean PEL quotients (m-PEL-q), pollution load index (PLI), mean ERM quotients (m-ERM-q) and total toxic unit (∑TU). Heavy metal speciation analysis indicated that gei wai pond improved the conversion from the immobilized Cd and Cr to the mobilized fraction. SEM-AVS analysis indicated no adverse toxicity occurred in all sites, and the role of TOC in relieving sediment heavy metal toxicity of gei wai pond is limited.

  12. A parameterization scheme for the x-ray linear attenuation coefficient and energy absorption coefficient.

    Science.gov (United States)

    Midgley, S M

    2004-01-21

    A novel parameterization of x-ray interaction cross-sections is developed, and employed to describe the x-ray linear attenuation coefficient and mass energy absorption coefficient for both elements and mixtures. The new parameterization scheme addresses the Z-dependence of elemental cross-sections (per electron) using a simple function of atomic number, Z. This obviates the need for a complicated mathematical formalism. Energy dependent coefficients describe the Z-direction curvature of the cross-sections. The composition dependent quantities are the electron density and statistical moments describing the elemental distribution. We show that it is possible to describe elemental cross-sections for the entire periodic table and at energies above the K-edge (from 6 keV to 125 MeV), with an accuracy of better than 2% using a parameterization containing not more than five coefficients. For the biologically important elements 1 coefficients. At higher energies, the parameterization uses fewer coefficients with only two coefficients needed at megavoltage energies.

  13. Segregation of chlorine in n-type tin monosulfide ceramics: Actual chlorine concentration for carrier-type conversion

    Science.gov (United States)

    Iguchi, Yuki; Sugiyama, Taiki; Inoue, Kazutoshi; Yanagi, Hiroshi

    2018-05-01

    Tin monosulfide (SnS) is an attractive material for photovoltaic cells because of its suitable band-gap energy, high absorption coefficient, and non-toxic and abundant constituent elements. The primary drawback of this material is the lack of n-type SnS. We recently demonstrated n-type SnS by doping with Cl. However, the Cl-doped n-type SnS bulk ceramics exhibited an odd behavior in which carrier-type conversion but not electron carrier concentration depended on the Cl concentration. In this study, the electron probe microanalysis (EPMA) elemental mapping of Cl-doped SnS revealed continuous homogeneous regions with a relatively low Cl concentration along with the islands of high Cl concentration in which Sn/S is far from unity. The difference between the Cl concentration in the homogeneous region (determined by EPMA) and the bulk Cl concentration (determined by wavelength-dispersive X-ray fluorescence spectroscopy) increased with the increasing Cl doping amount. The carrier concentration and the Hall coefficient clearly depended on the Cl concentration in the homogeneous region. Carrier-type conversion was observed at the Cl concentration of 0.26 at. % (in the homogeneous region).

  14. New national conversion line for Bactoscan FC in Italy: A step forward

    Directory of Open Access Journals (Sweden)

    G. Bolzoni

    2015-06-01

    Full Text Available To improve the reproducibility of flow cytometry technique for total bacterial count in milk, a conversion from instrumental results (impulses/μL to the reference method resultes (cfu/mL is needed. In 2008 in Italy, a project for a common conversion line for Bactoscan FC was initiated.In this paper we report on the second phase of the project focusing on the statistical procedure used to evaluate the validity of the data. The new conversion line, representative of national milk(2,732 valid samples from 29 labs obtained from both rounds of the study is: Log10 (cfu mL-1 = Log10 (IBC μL-1 x 0.939 + 2.559, with S y:x= 0.282 with an application range up to 70,000 IBC μL-1.

  15. Implementation elements for conversion of general-purpose freeway lane into high-occupancy-vehicle lane

    Science.gov (United States)

    1997-01-01

    Conversion of a general-purpose freeway into a high-occupancy-vehicle (HOV) lane is an alternative to infrastructure addition for HOV system implementation. Research indicates that lane conversion is feasible technically if sufficient HOV usage and m...

  16. Measurement of heat transfer coefficient using termoanemometry methods

    Science.gov (United States)

    Dančová, P.; Sitek, P.; Vít, T.

    2014-03-01

    This work deals with a measurement of heat transfer from a heated flat plate on which a synthetic jet impacts perpendicularly. Measurement of a heat transfer coefficient (HTC) is carried out using the hot wire anemometry method with glue film probe Dantec 55M47. The paper brings also results of velocity profiles measurements and turbulence intensity calculations.

  17. Uranium conversion; Urankonvertering

    Energy Technology Data Exchange (ETDEWEB)

    Oliver, Lena; Peterson, Jenny; Wilhelmsen, Katarina [Swedish Defence Research Agency (FOI), Stockholm (Sweden)

    2006-03-15

    FOI, has performed a study on uranium conversion processes that are of importance in the production of different uranium compounds in the nuclear industry. The same conversion processes are of interest both when production of nuclear fuel and production of fissile material for nuclear weapons are considered. Countries that have nuclear weapons ambitions, with the intention to produce highly enriched uranium for weapons purposes, need some degree of uranium conversion capability depending on the uranium feed material available. This report describes the processes that are needed from uranium mining and milling to the different conversion processes for converting uranium ore concentrate to uranium hexafluoride. Uranium hexafluoride is the uranium compound used in most enrichment facilities. The processes needed to produce uranium dioxide for use in nuclear fuel and the processes needed to convert different uranium compounds to uranium metal - the form of uranium that is used in a nuclear weapon - are also presented. The production of uranium ore concentrate from uranium ore is included since uranium ore concentrate is the feed material required for a uranium conversion facility. Both the chemistry and principles or the different uranium conversion processes and the equipment needed in the processes are described. Since most of the equipment that is used in a uranium conversion facility is similar to that used in conventional chemical industry, it is difficult to determine if certain equipment is considered for uranium conversion or not. However, the chemical conversion processes where UF{sub 6} and UF{sub 4} are present require equipment that is made of corrosion resistant material.

  18. Energy distribution for Coefficients of Redundant Signal Representations of Music

    DEFF Research Database (Denmark)

    Endelt, Line Ørtoft; la Cour-Harbo, Anders

    2005-01-01

    different time-frequency dictionaries. We have applied these methods to music to examine their ability to express music signals in a sparse manner for a number of dictionaries and window lengths. The evaluation is based on the m-term approximation needed to represent 90 %, 95 %, 99 % and 99......In this paper we investigate how the energy is distributed in the coefficients vector of various redundant signal representations of music signals. The representations are found using Basis Pursuit, Matching Pursuit, Alternating Projections, Best Orthogonal Basis and Method of Frames, with five.......9 % of the energy in the coefficients, also the time consummation for finding the representations are considered. The distribution of energy in the coefficients of the representations found using Basis Pursuit, Matching Pursuit, Alternating Projections and Best Orthogonal Basis depends mainly on the signal...

  19. Broadband wavelength conversion in hydrogenated amorphous silicon waveguide with silicon nitride layer

    Science.gov (United States)

    Wang, Jiang; Li, Yongfang; Wang, Zhaolu; Han, Jing; Huang, Nan; Liu, Hongjun

    2018-01-01

    Broadband wavelength conversion based on degenerate four-wave mixing is theoretically investigated in a hydrogenated amorphous silicon (a-Si:H) waveguide with silicon nitride inter-cladding layer (a-Si:HN). We have found that enhancement of the non-linear effect of a-Si:H waveguide nitride intermediate layer facilitates broadband wavelength conversion. Conversion bandwidth of 490 nm and conversion efficiency of 11.4 dB were achieved in a numerical simulation of a 4 mm-long a-Si:HN waveguide under 1.55 μm continuous wave pumping. This broadband continuous-wave wavelength converter has potential applications in photonic networks, a type of readily manufactured low-cost highly integrated optical circuits.

  20. Research and development of groundwater dating (Part 3). A proposal of determination method for diffusion coefficients of dissolved helium in rock and applicability of estimation of diffusion coefficients using anions

    International Nuclear Information System (INIS)

    Higashihara, Tomohiro; Nakata, Kotaro; Hasegawa, Takuma

    2006-01-01

    Dissolved helium in groundwater is one of the most suitable tracers for the groundwater dating. The diffusion coefficients in aquitard and aquifer were important to estimate an accumulation of the helium in groundwater. However, few papers have been reported about the diffusion of helium in rocks. In this study, effective diffusion coefficients of the helium in sandstones and mudstone were determined using a through-diffusion method. The effective diffusion coefficients of helium were in the range of 1.5 x 10 -10 to 1.1 x 10 -9 m 2 s -1 and larger than those of Br - ions. Geometrical factors for the diffusion of helium were also larger than those for the diffusion of Br - ions. This fact suggests that diffusion path of helium in the rocks is not more restricted than that of Br - ions. The diffusion coefficients of helium were also estimated using the diffusion coefficient of helium in bulk water and formation factors for diffusion of Br - ions. The estimated diffusion coefficients of helium were larger than the effective diffusion coefficients. It is clarified that the effective diffusion coefficients of helium are underestimated by the estimation method using anions. (author)

  1. Gallbladder Nonvisualization in Cholecystectomy: A Factor for Conversion.

    Science.gov (United States)

    Slack, Daniel R; Grisby, Shaunda; Dike, Uzoamaka Kimberly; Kohli, Harjeet

    2018-01-01

    Many risk factors have been identified in minimally invasive cholecystectomies that lead to higher complications and conversion rates. No study that we encountered looked at nonvisualization of the gallbladder (GB) during surgery as a risk factor. We hypothesized that nonvisualization was associated with an increased risk of complications and could be an early intraoperative identifier of a higher risk procedure. Recognizing this could allow surgeons to be aware of potential risks and to be more likely to convert to open for the safety of the patient. We looked at minimally invasive cholecystectomies performed at our institution from January 2015 through April 2016 and had the performing resident fill out a survey after the surgery. Outcomes were conversion rates, intraoperative complications, and blood loss and were analyzed via Pearson χ 2 test or Mann-Whitney U test. The primary outcome showed a conversion rate of 37% in nonvisualized GBs versus 0% in visualized ( P = .001). Secondary outcomes showed significant differences in GB perforations (74% vs 13%, P = .001), omental vessel bleeding (16% vs. 0%, P = .005), and EBL (46 mL vs 29 mL, P = .001). Intraoperative nonvisualization of the GB after adequate positioning caused significantly increased risk of intraoperative complications and conversion. This knowledge could be useful during intraoperative assessment, to decide whether a case should be continued as a minimally invasive procedure or converted early to help reduce risk to the patient. Further randomized controlled studies should be performed to further demonstrate the value of this assessment.

  2. Conversion to belatacept in maintenance kidney-transplant patients: A retrospective multicenter European study.

    Science.gov (United States)

    Darres, Amandine; Ulloa, Camillo; Brakemeier, Susanne; Garrouste, Cyril; Bestard, Oriol; Del Bello, Arnaud; Sberro Soussan, Rebecca; Dürr, Michael; Budde, Klemens; Legendre, Christophe; Kamar, Nassim

    2018-03-22

    The use of belatacept is not yet approved for maintenance kidney-transplant patients. This retrospective multicenter European study aimed to assess the efficacy and safety of conversion to belatacept in a large cohort of patients in a real-life setting, and to identify the predictive factors for improved kidney function after the switch. Two-hundred and nineteen maintenance kidney-transplant patients from 5 European kidney-transplant centers were converted to belatacept at 21.2 (0.1-337.1) months posttransplantation, mainly because of impaired kidney function. Thirty-two patients were converted to belatacept within the first 3 months posttransplantation. The mean duration of follow-up was 21.9±20.2 months. The actuarial rate of patients still on belatacept-based therapy was 77.6%. Mean estimated glomerular-filtration rate (eGFR) increased from 32±16.4 at baseline to 38±20 mL/min/1.73 m (ppredictive factor for a significant increase in eGFR (of 5 and 10 mL/min/1.73 m at 3 and 12 months after the switch, respectively). Eighteen patients (8.2%) presented with an acute-rejection episode after conversion; 3 developed a donor-specific antibody (DSA). Overall efficacy and safety were good, including for the 35 patients that had a DSA at conversion. The conversion to belatacept was effective, especially when performed early after transplantation.

  3. Performance of various quantum-key-distribution systems using 1.55-μm up-conversion single-photon detectors

    International Nuclear Information System (INIS)

    Diamanti, Eleni; Takesue, Hiroki; Honjo, Toshimori; Inoue, Kyo; Yamamoto, Yoshihisa

    2005-01-01

    We compare the performance of various quantum-key-distribution (QKD) systems using a single-photon detector, which combines frequency up-conversion in a periodically poled lithium niobate waveguide and a silicon avalanche photodiode (APD). The comparison is based on the secure communication rate as a function of distance for three QKD protocols: the Bennett-Brassard 1984, the Bennett-Brassard-Mermin 1992, and the coherent differential-phase-shift keying protocols. We show that the up-conversion detector allows for higher communication rates and longer communication distances than the commonly used InGaAs/InP APD for all three QKD protocols

  4. Laboratory measurements of the coefficient of thermal expansion of Olkiluoto drill core samples

    International Nuclear Information System (INIS)

    Aakesson, U.

    2012-04-01

    The coefficient of thermal expansion and the wet density has been determined on 22 specimens from the ONKALO drillholes ONK-PP167, ONK-PP199, ONK-PP224, ONK-PP225 and ONK-PP226, Olkiluoto, Finland. The coefficient of thermal expansion has been determined in the temperature interval 20-60 deg C. The results indicated that the thermal expansion was almost linear, and the coefficient of thermal expansion for the investigated specimens range between 3.2 and 14.4 x 10 -6 mm/mm deg C, and the wet density between 2,610 and 2,820 kg/m 3 . The granite pegmatite has slightly lower coefficient of thermal expansion and wet density than gneissic rocks. (orig.)

  5. Uranium soft x-ray total attenuation coefficients

    International Nuclear Information System (INIS)

    Del Grande, N.K.; Oliver, A.J.

    1981-01-01

    Uranium total attenuation coefficients were measured continuously from 0.84 to 6.0 keV and at selected higher energies using a vacuum single crystal diffractometer and flow-proportional counter. Statistical fluctuations ranged from 0.5% to 2%. The overall accuracy was 3%. Prominent structure was measured within 20 eV of the M 5 (3.552 keV) and M 4 (3.728 keV) edges. Jump ratios were determined from log-log polynomial fits to data at energies apart from the near-edge regions. These data were compared with calculations based on a relativistic HFS central potential model and with previously tabulated data

  6. Conversion from RSX-11D to RSX-11M or: did I really want to do it

    International Nuclear Information System (INIS)

    Giesler, G.C.

    1984-01-01

    The LAMPF Nuclear Chemistry Data Acquisition System (DAS) is used to acquire and to process data from a variety of nuclear chemistry experiments. In June 1977, the DAS was upgraded to a PDP-11/34 and RSX-11D V6.2 and FORTRAN 4-PLUS V2.5. That software remained in use until January, 1984 even though the PDP-11/34 was replaced by a PDP-11/44, and a number of peripherals were added or replaced. The arrival and installation of an RA-60 disk system forced us to upgrade to RSX-11M V4.1 and FORTRAN-77 V5.0. This was not without much pain and many problems. There was a change in functionality, and some things did not work as they previously had worked. A description of some of the changes in the DAS and of the problems in going from the ancient to the current software will be given as well as an evaluation of the results obtained so far in the conversion

  7. Measurement of particle transport coefficients on Alcator C-Mod

    Energy Technology Data Exchange (ETDEWEB)

    Luke, T.C.T.

    1994-10-01

    The goal of this thesis was to study the behavior of the plasma transport during the divertor detachment in order to explain the central electron density rise. The measurement of particle transport coefficients requires sophisticated diagnostic tools. A two color interferometer system was developed and installed on Alcator C-Mod to measure the electron density with high spatial ({approx} 2 cm) and high temporal ({le} 1.0 ms) resolution. The system consists of 10 CO{sub 2} (10.6 {mu}m) and 4 HeNe (.6328 {mu}m) chords that are used to measure the line integrated density to within 0.08 CO{sub 2} degrees or 2.3 {times} 10{sup 16}m{sup {minus}2} theoretically. Using the two color interferometer, a series of gas puffing experiments were conducted. The density was varied above and below the threshold density for detachment at a constant magnetic field and plasma current. Using a gas modulation technique, the particle diffusion, D, and the convective velocity, V, were determined. Profiles were inverted using a SVD inversion and the transport coefficients were extracted with a time regression analysis and a transport simulation analysis. Results from each analysis were in good agreement. Measured profiles of the coefficients increased with the radius and the values were consistent with measurements from other experiments. The values exceeded neoclassical predictions by a factor of 10. The profiles also exhibited an inverse dependence with plasma density. The scaling of both attached and detached plasmas agreed well with this inverse scaling. This result and the lack of change in the energy and impurity transport indicate that there was no change in the underlying transport processes after detachment.

  8. Measurement of particle transport coefficients on Alcator C-Mod

    International Nuclear Information System (INIS)

    Luke, T.C.T.

    1994-10-01

    The goal of this thesis was to study the behavior of the plasma transport during the divertor detachment in order to explain the central electron density rise. The measurement of particle transport coefficients requires sophisticated diagnostic tools. A two color interferometer system was developed and installed on Alcator C-Mod to measure the electron density with high spatial (∼ 2 cm) and high temporal (≤ 1.0 ms) resolution. The system consists of 10 CO 2 (10.6 μm) and 4 HeNe (.6328 μm) chords that are used to measure the line integrated density to within 0.08 CO 2 degrees or 2.3 x 10 16 m -2 theoretically. Using the two color interferometer, a series of gas puffing experiments were conducted. The density was varied above and below the threshold density for detachment at a constant magnetic field and plasma current. Using a gas modulation technique, the particle diffusion, D, and the convective velocity, V, were determined. Profiles were inverted using a SVD inversion and the transport coefficients were extracted with a time regression analysis and a transport simulation analysis. Results from each analysis were in good agreement. Measured profiles of the coefficients increased with the radius and the values were consistent with measurements from other experiments. The values exceeded neoclassical predictions by a factor of 10. The profiles also exhibited an inverse dependence with plasma density. The scaling of both attached and detached plasmas agreed well with this inverse scaling. This result and the lack of change in the energy and impurity transport indicate that there was no change in the underlying transport processes after detachment

  9. Contact in Adoption and Adoptive Identity Formation: The Mediating Role of Family Conversation

    Science.gov (United States)

    Korff, Lynn Von; Grotevant, Harold D.

    2012-01-01

    The present study examined adoption-related family conversation as a mediator of the association between adoptive parents’ facilitation of contact with birth relatives and adolescent adoptive identity formation. The sample consisted of 184 adoptive families. Data were collected in two waves from adoptive mothers and fathers, and adoptees (M = 15.68 years at adolescence; M = 24.95 years at emerging adulthood) using semistructured interviews and questionnaires. Structural equation models showed a good fit to sample data, and analyses supported the hypothesized mediation model. Contact with birth relatives is associated with more frequent adoption-related family conversation, which in turn is associated with the development of adoptive identity. These results highlight the importance of supporting activities such as contact that lead to adoption-related family conversation. PMID:21517175

  10. Challenges of ICRP 60 for uranium refining and conversion facilities

    International Nuclear Information System (INIS)

    Takala, J.M.

    1998-01-01

    Cameco Corporation operates high-grade uranium mines in northern Saskatchewan and uranium refining and conversion facilities in Ontario. The dose limits for these and all other nuclear facilities in Canada are 50 mSv per year and 4 WLM per year, which are applied separately. However, the upcoming incorporation of the recommendations in ICRP 60 into the Canadian regulations will result in several important changes. In addition to a more restrictive dose limit, the new regulations will require that all radiation exposures be combined into a single index of exposure. Meeting the new lower dose limits of 50 mSv per year and 100 mSv per 5 years will not be a major problem at Cameco facilities. However, the incorporation of long-lived radioactive dust exposures into the dose calculation will be a major challenge. This will cause the most difficulty at the uranium refining and conversion facilities where much of the process involves handling a variety of uranium compounds in the form of a dry powder. At the uranium conversion facilities the control of exposure to airborne uranium is achieved through a combination of lung counting, urinalysis, and fixed area monitors. To progress from a system of exposure control to dose estimation to individual workers will require some major changes. (author)

  11. La conversion dans le code de droit canonique de l’Église catholique de rite latin Conversion in the canon law code of the Latin rite Catholic Church

    Directory of Open Access Journals (Sweden)

    Jeanne-Marie Tuffery-Andrieu

    2009-10-01

    Full Text Available Même si le terme lui-même n’est que rarement utilisé, la conversion est évoquée à plusieurs reprises dans le code de droit canonique de l’Église catholique de rite latin et présente un des enjeux majeurs de la norme ecclésiale. Le Code de 1983, conformément aux principes théologiques établis, fixe en effet les moyens de la conversion du baptisé catholique, et tire les conséquences de la conversion du non baptisé.Even if the word itself is very rarely used, conversion is evoked several times in the canon law code of the Latin rite Catholic Church. It constitutes one of the major stakes of the Church norm. The 1983 Code, according to the established theological principles, determines the means of the conversion of baptized Catholics, and draws conclusions from the conversion of the non-baptized.

  12. New external convective heat transfer coefficient correlations for isolated low-rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Emmel, M. G.; Mendes, N. [Pontifical Catholic University of Parana, PUCPR/CCET, Thermal Systems Laboratory, LST, Curitiba (Brazil); Abadie, M. O. [Pontifical Catholic University of Parana, PUCPR/CCET, Thermal Systems Laboratory, LST, Curitiba (Brazil); Laboratoire d' Etude des Phenomenes de Transfert Appliques au batiment (LEPTAB), University of La Rochelle, La Rochelle (France)

    2007-07-01

    Building energy analyses are very sensitive to external convective heat transfer coefficients so that some researchers have conducted sensitivity calculations and proved that depending on the choice of those coefficients, energy demands estimation values can vary from 20% to 40%. In this context, computational fluid dynamics calculations have been performed to predict convective heat transfer coefficients at the external surfaces of a simple shape low-rise building. Effects of wind velocity and orientation have been analyzed considering four surface-to-air temperature differences. Results show that the convective heat transfer coefficient value strongly depends on the wind velocity, that the wind direction has a notable effect for vertical walls and for roofs and that the surface-to-air temperature difference has a negligible effect for wind velocity higher than 2 m/s. External convective heat transfer coefficient correlations are provided as a function of the wind free stream velocity and wind-to-surface angle. (author)

  13. Ultralow power continuous-wave frequency conversion in hydrogenated amorphous silicon waveguides.

    Science.gov (United States)

    Wang, Ke-Yao; Foster, Amy C

    2012-04-15

    We demonstrate wavelength conversion through nonlinear parametric processes in hydrogenated amorphous silicon (a-Si:H) with maximum conversion efficiency of -13 dB at telecommunication data rates (10 GHz) using only 15 mW of pump peak power. Conversion bandwidths as large as 150 nm (20 THz) are measured in continuous-wave regime at telecommunication wavelengths. The nonlinear refractive index of the material is determined by four-wave mixing (FWM) to be n(2)=7.43×10(-13) cm(2)/W, approximately an order of magnitude larger than that of single crystal silicon. © 2012 Optical Society of America

  14. Frequency conversion of high-intensity, femtosecond laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Banks, P S

    1997-06-01

    Almost since the invention of the laser, frequency conversion of optical pulses via non- linear processes has been an area of active interest. However, third harmonic generation using ~(~1 (THG) in solids is an area that has not received much attention because of ma- terial damage limits. Recently, the short, high-intensity pulses possible with chirped-pulse amplification (CPA) laser systems allow the use of intensities on the order of 1 TW/cm2 in thin solids without damage. As a light source to examine single-crystal THG in solids and other high field inter- actions, the design and construction of a Ti:sapphire-based CPA laser system capable of ultimately producing peak powers of 100 TW is presented. Of special interest is a novel, all-reflective pulse stretcher design which can stretch a pulse temporally by a factor of 20,000. The stretcher design can also compensate for the added material dispersion due to propagation through the amplifier chain and produce transform-limited 45 fs pulses upon compression. A series of laser-pumped amplifiers brings the peak power up to the terawatt level at 10 Hz, and the design calls for additional amplifiers to bring the power level to the 100 TW level for single shot operation. The theory for frequency conversion of these short pulses is presented, focusing on conversion to the third harmonic in single crystals of BBO, KD*P, and d-LAP (deuterated I-arginine phosphate). Conversion efficiencies of up to 6% are obtained with 500 fs pulses at 1053 nm in a 3 mm thick BBO crystal at 200 GW/cm 2. Contributions to this process by unphasematched, cascaded second harmonic generation and sum frequency generation are shown to be very significant. The angular relationship between the two orders is used to measure the tensor elements of C = xt3)/4 with Crs = -1.8 x 1O-23 m2/V2 and .15Cri + .54Crs = 4.0 x 1O-23 m2/V2. Conversion efficiency in d-LAP is about 20% that in BBO and conversion efficiency in KD*P is 1% that of BBO. It is calculated

  15. Weyl q-coefficients for uq(3) and Racah q -coefficients for suq(2)

    International Nuclear Information System (INIS)

    Asherova, R.M.; Smirnov, Yu.F.; Tolstoy, V.N.

    1996-01-01

    With the aid of the projection-operator technique, the general analytic expression for the elements of the matrix that relates the U and T bases of an arbitrary finite-dimensional irreducible representation of the uq(3) quantum algebra (Weyl q-coefficients) is obtained for the case where the deformation parameter q is not equal to a square root of unity. The procedure for resummation of q-factorial expressions is used to prove that, modulo phase factors, these Weyl q-coefficients coincide with Racah q-coefficients for the suq(2) quantum algebra. It is also shown that, on the basis of one general formula, the q-analogs of all known general analytic expressions for the 6j symbols (and Racah coefficients) of the Lie algebras of the angular momentum can be obtained by using this resummation procedure. The symmetry properties of these q coefficients are discussed. The result is formulated in the following way: the general formulas for the q-6j symbols (Racah q-coefficients) of the suq(2) quantum algebra are obtained from the general formulas for the conventional 6j symbols (Racah coefficients) of the su(2) Lie algebra by replacing directly all factorials with q-factorials, the symmetry properties of the q-6j symbols being completely coincident with the symmetry properties of the conventional 6j symbols

  16. The diffusion coefficient for 239Pu, 241Am, 99Tc and 137Cs in highly compacted buffer materials

    International Nuclear Information System (INIS)

    Zhou Kanghan; Li Guoding

    1998-01-01

    Based on one-dimension diffusion model, the diffusion coefficients of Pu, Am, Tc and Cs in highly compacted sodium-bentonite generally used as buffer materials in geologic disposal system for high-level radioactive waste have been determined at room temperature in the atmosphere of nitrogen. The results show that the diffusion coefficients of Am, Pu and Tc and about 10 -13 ∼10 -15 m 2 /s, and that of Cs about 10 -12 m 2 /s. The diffusion coefficients of these elements decrease with the increasing of the dry density of buffer materials. From the relationship of diffusion coefficient, retardation coefficient and dry density of bentonite, it has been concluded that Am and Pu transfer predominately by diffusion in solid phase, however, Cs and Tc by diffusion in pore water

  17. Nanostructured Solar Irradiation Control Materials for Solar Energy Conversion

    Science.gov (United States)

    Kang, Jinho; Marshall, I. A.; Torrico, M. N.; Taylor, C. R.; Ely, Jeffry; Henderson, Angel Z.; Kim, J.-W.; Sauti, G.; Gibbons, L. J.; Park, C.; hide

    2012-01-01

    Tailoring the solar absorptivity (alpha(sub s)) and thermal emissivity (epsilon(sub T)) of materials constitutes an innovative approach to solar energy control and energy conversion. Numerous ceramic and metallic materials are currently available for solar absorbance/thermal emittance control. However, conventional metal oxides and dielectric/metal/dielectric multi-coatings have limited utility due to residual shear stresses resulting from the different coefficient of thermal expansion of the layered materials. This research presents an alternate approach based on nanoparticle-filled polymers to afford mechanically durable solar-absorptive and thermally-emissive polymer nanocomposites. The alpha(sub s) and epsilon(sub T) were measured with various nano inclusions, such as carbon nanophase particles (CNPs), at different concentrations. Research has shown that adding only 5 wt% CNPs increased the alpha(sub s) and epsilon(sub T) by a factor of about 47 and 2, respectively, compared to the pristine polymer. The effect of solar irradiation control of the nanocomposite on solar energy conversion was studied. The solar irradiation control coatings increased the power generation of solar thermoelectric cells by more than 380% compared to that of a control power cell without solar irradiation control coatings.

  18. Conversion of the reducing substances and the indices of sugar solutions

    Directory of Open Access Journals (Sweden)

    V. A. Golybin

    2017-01-01

    Full Text Available Investigated the extent of adsorption removal of calcium carbonate pigments - products of conversion of the reducing substances in different conditions of the preceding limestone processing flow. Also carried out experiments on the influence of the conditions of conversion of the reducing substances in the process of lime treatment on the filtration characteristics of the solutions after the first carbonation. As the criterion was accepted the value of the filtration coefficient. Found that by subjecting the conversion of reducing substances in the process managed lime processing, it is necessary in the course of the subsequent carbonization to ensure maximum adsorption of the formed secondary products – it is possible to achieve a satisfactory filtration of the investigated solutions. It is shown that the largest absolute removal of the dyes obtained after high temperature lime treatment, however, the composition of the products of disintegration to a greater extent accumulate high molecular weight compounds which deteriorate the filtration performance of solutions. In the solutions after the combination of the lime treatment in the process of carbonization is achieved the maximum effect of adsorption with the minimum remaining shares of conversion products, including high-molecular substances, which favorably affect the parameters of the filtering. The combination possibilities of the model of purification of diffusion juice with warm-hot lime treatment is limited to receive the filtered juice in the processing of raw materials with a purity of beet juice 82 % or less, you need to enter a 3.5% Cao, which is unacceptable. To ensure sustainable results of the adsorption of conversion products reducing substances and satisfactory filtering carbonated solutions are to intensify the processes of combined lime processing diffusion juice at the optimum distribution of the reagent.

  19. [Determination of a Friction Coefficient for THA Bearing Couples].

    Science.gov (United States)

    Vrbka, M; Nečas, D; Bartošík, J; Hartl, M; Křupka, I; Galandáková, A; Gallo, J

    2015-01-01

    The wear of articular surfaces is considered one of the most important factors limiting the life of total hip arthroplasty (THA). It is assumed that the particles released from the surface of a softer material induce a complex inflammatory response, which will eventually result in osteolysis and aseptic loosening. Implant wear is related to a friction coefficient which depends on combination of the materials used, roughness of the articulating surfaces, internal clearance, and dimensions of the prosthesis. The selected parameters of the bearing couples tested were studied using an experimental device based on the principle of a pendulum. Bovine serum was used as a lubricant and the load corresponded to a human body mass of 75 kg. The friction coefficient was derived from a curve of slowdown of pendulum oscillations. Roughness was measured with a device working on the principle of interferometry. Clearance was assessed by measuring diameters of the acetabular and femoral heads with a 3D optical scanner. The specimens tested included unused metal-on-highly cross-linked polyethylene, ceramic-on-highly cross-linked polyethylene and ceramic-on-ceramic bearing couples with the diameters of 28 mm and 36 mm. For each measured parameter, an arithmetic mean was calculated from 10 measurements. 1) The roughness of polyethylene surfaces was higher by about one order of magnitude than the roughness of metal and ceramic components. The Protasul metal head had the least rough surface (0.003 μm). 2) The ceramic-on-ceramic couples had the lowest clearance. Bearing couples with polyethylene acetabular liners had markedly higher clearances ranging from 150 μm to 545 μm. A clearance increased with large femoral heads (up to 4-fold in one of the couple tested). 3) The friction coefficient was related to the combination of materials; it was lowest in ceramic-on-ceramic surfaces (0.11 to 0.12) and then in ceramic-on-polyethylene implants (0.13 to 0.14). The friction coefficient is

  20. The Truth About Ballistic Coefficients

    OpenAIRE

    Courtney, Michael; Courtney, Amy

    2007-01-01

    The ballistic coefficient of a bullet describes how it slows in flight due to air resistance. This article presents experimental determinations of ballistic coefficients showing that the majority of bullets tested have their previously published ballistic coefficients exaggerated from 5-25% by the bullet manufacturers. These exaggerated ballistic coefficients lead to inaccurate predictions of long range bullet drop, retained energy and wind drift.

  1. Conversion of far ultraviolet to visible radiation: absolute measurements of the conversion efficiency of tetraphenyl butadiene

    Science.gov (United States)

    Vest, Robert E.; Coplan, Michael A.; Clark, Charles W.

    Far ultraviolet (FUV) scintillation of noble gases is used in dark matter and neutrino research and in neutron detection. Upon collisional excitation, noble gas atoms recombine into excimer molecules that decay by FUV emission. Direct detection of FUV is difficult. Another approach is to convert it to visible light using a wavelength-shifting medium. One such medium, tetraphenyl butadiene (TPB) can be vapor-deposited on substrates. Thus the quality of thin TPB films can be tightly controlled. We have measured the absolute efficiency of FUV-to-visible conversion by 1 μm-thick TPB films vs. FUV wavelengths between 130 and 300 nm, with 1 nm resolution. The energy efficiency of FUV to visible conversion varies between 1% and 5%. We make comparisons with other recent results. Work performed at the NIST SURF III Synchrotron Ultraviolet Radiation Facility,.

  2. Advances in copper-chalcopyrite thin films for solar energy conversion

    Energy Technology Data Exchange (ETDEWEB)

    Kaneshiro, Jess; Gaillard, Nicolas; Rocheleau, Richard; Miller, Eric [Hawaii Natural Energy Institute, University of Hawaii at Manoa, 1680 East-West Road, Post 109, Honolulu, HI 96822 (United States)

    2010-01-15

    Promising alternatives to crystalline silicon as the basic building block of solar cells include copper-chalcopyrite thin films such as copper indium gallium diselenide, a class of thin films exhibiting bandgap-tunable semiconductor behavior, direct bandgaps and high absorption coefficients. These properties allow for the development of novel solar-energy conversion configurations like ultra-high efficiency multi-junction solar cells utilizing combinations of photovoltaic and photoelectrochemical junctions for hydrogen production. This paper discusses the current worldwide status as well as the development and optimization of copper-chalcopyrite thin films deposited onto various substrate types for different photovoltaic and photoelectrochemical applications at the Hawaii Natural Energy Institute. (author)

  3. Coefficient of reversibility and two particular cases of deterministic many body systems

    International Nuclear Information System (INIS)

    Grossu, Ioan Valeriu; Besliu, Calin; Jipa, Alexandru

    2004-01-01

    We discuss the importance of a new measure of chaos in study of nonlinear dynamic systems, the - coefficient of reversibility-. This is defined as the probability of returning in the same point of phasic space. Is very interesting to compare this coefficient with other measures like fractal dimension or Liapunov exponent. We have also studied two very interesting many body systems, both having any number of particles but a deterministic evolution. One system is composed by n particles initially at rest, having the same mass and interacting through harmonic bi-particle forces, other is composed by two types of particles (with mass m 1 and mass m 2 ) initially at rest and interacting too through harmonic bi-particle forces

  4. Measurement of heat transfer coefficient using termoanemometry methods

    Directory of Open Access Journals (Sweden)

    Dančová P.

    2014-03-01

    Full Text Available This work deals with a measurement of heat transfer from a heated flat plate on which a synthetic jet impacts perpendicularly. Measurement of a heat transfer coefficient (HTC is carried out using the hot wire anemometry method with glue film probe Dantec 55M47. The paper brings also results of velocity profiles measurements and turbulence intensity calculations.

  5. Determination of 131mXe and 133mXe in the presence of 133gXe via combined beta-spectroscopy and delayed coincidence

    International Nuclear Information System (INIS)

    Reeder, P.L.; Bowyer, T.W.; McIntyre, J.I.; Pitts, W.K.

    2001-01-01

    The International Monitoring System for the Comprehensive Nuclear-Test-Ban Treaty will include measurements of Xe fission products. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which detects Xe fission products using a beta-gamma counting system for 131m Xe, 133m Xe, 133g Xe, and 135g Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse-height spectra of gamma-energy versus beta-energy are obtained. The plastic scintillator spectrum in coincidence with the 31-keV X-rays from 131m Xe. 133m Xe, and 133g Xe is a complex mixture of conversion electrons and betas. A new technique to simultaneously measure the delayed coincidence (T 1/2 = 6.27 ns) between beta-particles from 133g Xe and conversion electrons depopulating the 81-keV state in 133 Cs is being developed. This technique allows separation of the 133g Xe beta spectrum from the conversion electrons due to 131m Xe and 133m Xe and uniquely quantifies all three nuclides. (author)

  6. Determination of 131m Xe and 133m Xe in the presence of 133gXe via combined beta-spectroscopy and delayed coincidence

    International Nuclear Information System (INIS)

    Reeder, Paul L.; Bowyer, Ted W.; McIntyre, Justin I.; Pitts, W K.

    2001-01-01

    The International Monitoring System for the Comprehensive Nuclear-Test-Ban Treaty will include measurements of Xe fission products. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which detects Xe fission products using a beta-gamma counting system for 131mXe, 133mXe, 133Xe, and 135Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse height spectra of gamma energy versus beta energy are obtained. The plastic scintillator spectrum in coincidence with the 31-keV X-rays from 131mXe. 133mXe, and 133Xe is a complex mixture of conversion electrons and betas. A new technique to simultaneously measure the delayed coincidence (t1/2 = 6.27 ns) between beta particles from 133Xe and conversion electrons depopulating the 81-keV state in 133Cs is being developed. This technique will allow separation of the 133Xe spectrum from the conversion electrons due to 131mXe and 133mXe and will uniquely quantify all three nuclides

  7. Physics and safety studies of a low conversion ratio sodium cooled fast reactor

    International Nuclear Information System (INIS)

    Cahalan, J. E.; Smith, M. A.; Hill, R. N.; Dunn, F. E.

    2004-01-01

    This paper explores the feasibility of a compact fast burner reactor that can achieve a low transuranic conversion ratio. The major design option considered is the reduction of fissile breeding by the removal of fertile material from the fast reactor system. Reductions in the fuel pin diameter and thus fuel loading were employed to remove fertile material. Reactor performance parameters and reactivity coefficients were evaluated for a compact core design with a targeted conversion ratio of 0.25. To assess the safety implications, a detailed transient analysis model was employed using the SAS4A/SASSYS-1 computer code. A series of calculations was performed to assess the behavior of the reactor and plant in an unprotected loss-of-flow accident (ULOF). A parametric study was also carried out using increasingly conservative modeling assumptions. The computational results show that for nominal, best-estimate analysis assumptions and input data, the low conversion ratio reactor design responds to the ULOF with a very high level of self-protection. Both short-term and long-term quasi-equilibrium reactor conditions predicted in the analysis indicate very large margins of safety. (authors)

  8. Development of database on the distribution coefficient. 1. Collection of the distribution coefficient data

    Energy Technology Data Exchange (ETDEWEB)

    Takebe, Shinichi; Abe, Masayoshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-03-01

    The distribution coefficient is very important parameter for environmental impact assessment on the disposal of radioactive waste arising from research institutes. The literature survey in the country was mainly carried out for the purpose of selecting the reasonable distribution coefficient value on the utilization of this value in the safety evaluation. This report was arranged much informations on the distribution coefficient for inputting to the database for each literature, and was summarized as a literature information data on the distribution coefficient. (author)

  9. DSCImageCalc – Software for Determining Similarity Coefficients for the Analysis of Image Segmentations

    Directory of Open Access Journals (Sweden)

    Tom Lawton

    2017-10-01

    Full Text Available DSCImageCalc is free software for calculating similarity coefficients on segmented images. It is written in Visual BASIC .NET and is available at: https://doi.org/10.6084/m9.figshare.894428. It presently calculates Sørensen-Dice Coefficient, Jaccard Coefficient, Proportional Agreement, Cohen’s Kappa, Goodman & Kruskal’s Gamma, and Rogot-Goldberg Agreement. It also calculates segment centroids and the distance between them. Whilst it was originally designed for calculating Dice coefficients on segmentations of ultrasound images, it has potential for re-use in any field where similarity of image segments is to be analysed; predominantly medical radiology and ecology.

  10. A Structural Modeling Approach to a Multilevel Random Coefficients Model.

    Science.gov (United States)

    Rovine, Michael J.; Molenaar, Peter C. M.

    2000-01-01

    Presents a method for estimating the random coefficients model using covariance structure modeling and allowing one to estimate both fixed and random effects. The method is applied to real and simulated data, including marriage data from J. Belsky and M. Rovine (1990). (SLD)

  11. Postoperative Conversion Disorder in Elderly Oral Cancer Patient.

    Science.gov (United States)

    Yakushiji, Takashi; Hayashi, Kamichika; Morikawa, Takamichi; Migita, Masashi; Ogane, Satoru; Muramatsu, Kyotaro; Kamio, Takashi; Shibahara, Takahiko; Takano, Nobuo

    2016-01-01

    Conversion disorder is a condition in which psychological stress in response to difficult situations manifests as physical symptoms. Here, we report a case of postoperative coma due to conversion disorder in an elderly oral cancer patient. An 82-year-old woman was referred to Tokyo Dental College Chiba Hospital with a mass lesion on the tongue. A biopsy revealed a well-differentiated squamous cell carcinoma. Surgical treatment was performed for the tongue carcinoma and tracheotomy for management of the airway. On postoperative day 5, the patient exhibited loss of consciousness (Glasgow Coma Scale: E1, VT, M1; Japan Coma Scale: III-300). The patient's vital signs were all normal, as were the results of a full blood count, brain-CT, MRI, and MRA. Only the arm dropping test was positive. Therefore, the cause of the coma was diagnosed as conversion disorder. Seven hours later, the patient showed a complete recovery.

  12. The dependence of the Taylor-Quinney coefficient on the dynamic loading mode

    Science.gov (United States)

    Rittel, D.; Zhang, L. H.; Osovski, S.

    2017-10-01

    The efficiency of the thermomechanical conversion, expressed as the Taylor-Quinney coefficient (TQC) is seldom reported in the literature and generally assumed to be equal to 0.9. Moreover, an eventual dependence of this coefficient on the dynamic loading mode has not been investigated so far. This work presents a systematic characterization of the TQC for seven different metals and alloys loaded in dynamic tension, compression and dominant shear. The results show that the TQC varies greatly with the investigated material, instead of its assumed constant value of 0.9. Likewise, until final collapse of the specimen, the overall temperature rise remains quite modest. Moreover, we clearly observe that for commercially pure Titanium, which exhibits an asymmetric mechanical response in tension and compression, the measured TQC values are mode dependent too. Microstructural characterization reveals profuse twinning in compression and shear, as opposed to tension. Twinning is related to heat generation in accord with previous studies. In addition to reporting a wide database of TQC values, this study reveals a new correlation between the thermomechanical characteristics of a material and its deformation micromechanisms, that should find its way into constitutive models.

  13. The Influence of Conditioning Agent on Phosphate Diffusion Coefficient through Polyacrylamide and Agarose Gel

    Directory of Open Access Journals (Sweden)

    Layta Dinira

    2013-03-01

    Full Text Available Excess phosphate in natural water can cause algae grow rapidly, to the extent causing many fish deaths that led to the extinction of certain species. Therefore, an analysis or periodic observations of phosphate levels in the water is needed. The commonly used method is diffusive gradient in thin films (DGT technique. The DGT technique is based on the ability of analyte to diffuse through a gel, which have a value named diffusion coefficient. This research was conducted in order to study the effect of different storage solution to the phosphate diffusion coefficient through polyacrylamide and agarose gels. Initial research performed with making the polyacrylamide and agarose gels. To observe the effect of different storage solutions, the gels partly stored in distilled water gel while the others are stored in a NaCl solution of 0.01 M. Phosphate diffusion coefficient was determined using Fick's Law after analyze the phosphate concentration using UV-Visible spectrophotometer. The results showed that phosphate diffusion coefficient was highest when polyacrylamide and agarose gels stored in NaCl solution of 0.01 M.

  14. Computers and conversation

    CERN Document Server

    Luff, Paul; Gilbert, Nigel G

    1986-01-01

    In the past few years a branch of sociology, conversation analysis, has begun to have a significant impact on the design of human*b1computer interaction (HCI). The investigation of human*b1human dialogue has emerged as a fruitful foundation for interactive system design.****This book includes eleven original chapters by leading researchers who are applying conversation analysis to HCI. The fundamentals of conversation analysis are outlined, a number of systems are described, and a critical view of their value for HCI is offered.****Computers and Conversation will be of interest to all concerne

  15. Experimental determination of the partitioning coefficient of β-pinene oxidation products in SOAs.

    Science.gov (United States)

    Hohaus, Thorsten; Gensch, Iulia; Kimmel, Joel; Worsnop, Douglas R; Kiendler-Scharr, Astrid

    2015-06-14

    The composition of secondary organic aerosols (SOAs) formed by β-pinene ozonolysis was experimentally investigated in the Juelich aerosol chamber. Partitioning of oxidation products between gas and particles was measured through concurrent concentration measurements in both phases. Partitioning coefficients (Kp) of 2.23 × 10(-5) ± 3.20 × 10(-6) m(3) μg(-1) for nopinone, 4.86 × 10(-4) ± 1.80 × 10(-4) m(3) μg(-1) for apoverbenone, 6.84 × 10(-4) ± 1.52 × 10(-4) m(3) μg(-1) for oxonopinone and 2.00 × 10(-3) ± 1.13 × 10(-3) m(3) μg(-1) for hydroxynopinone were derived, showing higher values for more oxygenated species. The observed Kp values were compared with values predicted using two different semi-empirical approaches. Both methods led to an underestimation of the partitioning coefficients with systematic differences between the methods. Assuming that the deviation between the experiment and the model is due to non-ideality of the mixed solution in particles, activity coefficients of 4.82 × 10(-2) for nopinone, 2.17 × 10(-3) for apoverbenone, 3.09 × 10(-1) for oxonopinone and 7.74 × 10(-1) for hydroxynopinone would result using the vapour pressure estimation technique that leads to higher Kp. We discuss that such large non-ideality for nopinone could arise due to particle phase processes lowering the effective nopinone vapour pressure such as diol- or dimer formation. The observed high partitioning coefficients compared to modelled results imply an underestimation of SOA mass by applying equilibrium conditions.

  16. Interferometric measurement of a diffusion coefficient: comparison of two methods and uncertainty analysis

    International Nuclear Information System (INIS)

    Riquelme, Rodrigo; Lira, Ignacio; Perez-Lopez, Carlos; Rayas, Juan A; RodrIguez-Vera, Ramon

    2007-01-01

    Two methods to measure the diffusion coefficient of a species in a liquid by optical interferometry were compared. The methods were tested on a 1.75 M NaCl aqueous solution diffusing into water at 26 deg. C. Results were D = 1.587 x 10 -9 m 2 s -1 with the first method and D = 1.602 x 10 -9 m 2 s -1 with the second method. Monte Carlo simulation was used to assess the possible dispersion of these results. The standard uncertainties were found to be of the order of 0.05 x 10 -9 m 2 s -1 with both methods. We found that the value of the diffusion coefficient obtained by either method is very sensitive to the magnification of the optical system, and that if diffusion is slow the measurement of time does not need to be very accurate

  17. Heat and mass transfer coefficients and modeling of infrared drying of banana slices

    Directory of Open Access Journals (Sweden)

    Fernanda Machado Baptestini

    Full Text Available ABSTRACT Banana is one of the most consumed fruits in the world, having a large part of its production performed in tropical countries. This product possesses a wide range of vitamins and minerals, being an important component of the alimentation worldwide. However, the shelf life of bananas is short, thus requiring procedures to prevent the quality loss and increase the shelf life. One of these procedures widely used is drying. This work aimed to study the infrared drying process of banana slices (cv. Prata and determine the heat and mass transfer coefficients of this process. In addition, effective diffusion coefficient and relationship between ripening stages of banana and drying were obtained. Banana slices at four different ripening stages were dried using a dryer with infrared heating source with four different temperatures (65, 75, 85, and 95 ºC. Midilli model was the one that best represented infrared drying of banana slices. Heat and mass transfer coefficients varied, respectively, between 46.84 and 70.54 W m-2 K-1 and 0.040 to 0.0632 m s-1 for temperature range, at the different ripening stages. Effective diffusion coefficient ranged from 1.96 to 3.59 × 10-15 m² s-1. Activation energy encountered were 16.392, 29.531, 23.194, and 25.206 kJ mol-1 for 2nd, 3rd, 5th, and 7th ripening stages, respectively. Ripening stages did not affect the infrared drying of bananas.

  18. Assessment of the integration of a He-cooled divertor system in the power conversion system for the dual-coolant blanket concept (TW2-TRP-PPCS12D8)

    International Nuclear Information System (INIS)

    Norajitra, P.; Kruessmann, R.; Malang, S.; Reimann, G.

    2002-12-01

    Application of a helium-cooled divertor together with the dual-coolant blanket concept is considered favourable for achieving a high thermal efficiency of the power plant due to its relatively high coolant outlet temperature. A new FZK He-cooled modular divertor concept with integrated pin arrays (HEMP) is introduced. Its main features and function are described in detail. The result of the thermalhydraulic analysis shows that the HEMP divertor concept has the potential of resisting, a heat flow density of at least 10-15 MW/m 2 at a reachable heat transfer coefficient of approx. 60 kW/m 2 K and a reasonable pumping power. Integration of this divertor concept into the power conversion system using a closed Brayton gas turbine system with three-stage compression leads to a net efficiency of the blanket/divertor cycle of about 43%. (orig.)

  19. Measurement and modeling of interface heat transfer coefficients

    International Nuclear Information System (INIS)

    Rollett, A.D.; Lewis, H.D.; Dunn, P.S.

    1985-01-01

    The results of preliminary work on the modeling and measurement of the heat transfer coefficients of metal/mold interfaces is reported. The system investigated is the casting of uranium in graphite molds. The motivation for the work is primarily to improve the accuracy of process modeling of prototype mold designs at the Los Alamos Foundry. The evolution in design of a suitable mold for unidirectional solidification is described, illustrating the value of simulating mold designs prior to use. Experiment indicated a heat transfer coefficient of 2 kW/m 2 /K both with and without superheat. It was possible to distinguish between solidification due to the mold and that due to radiative heat loss. This permitted an experimental estimate of the emissivity, epsilon = 0.2, of the solidified metal

  20. Extending the Constant Coefficient Solution Technique to Variable Coefficient Ordinary Differential Equations

    Science.gov (United States)

    Mohammed, Ahmed; Zeleke, Aklilu

    2015-01-01

    We introduce a class of second-order ordinary differential equations (ODEs) with variable coefficients whose closed-form solutions can be obtained by the same method used to solve ODEs with constant coefficients. General solutions for the homogeneous case are discussed.

  1. Obtaining the conversion curve of CT numbers to electron density from the effective energy of the CT using the dummy SEFM; Obtencion de la curva de conversion de numeros TC a densidad electronica a partir de la energia efectiva del TC usando el maniqui de la SEFM

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Viera Cueto, J. A.; Garcia Pareja, S.; Benitez Villegas, E. M.; Moreno Saiz, E. M.; Bodineau Gil, C.; Caudepon Moreno, F.

    2011-07-01

    The objective of this work is to obtain the conversion curve of Hounsfield units (A) versus electron densities using a mannequin with different tissue equivalent materials. This provides for the effective energy beam CT and is used to characterize the linear coefficients of absorption of different materials that comprise the dummy.

  2. Contact in adoption and adoptive identity formation: the mediating role of family conversation.

    Science.gov (United States)

    Von Korff, Lynn; Grotevant, Harold D

    2011-06-01

    The present study examined adoption-related family conversation as a mediator of the association between adoptive parents' facilitation of contact with birth relatives and adolescent adoptive identity formation. The sample consisted of 184 adoptive families. Data were collected in two waves from adoptive mothers and fathers, and adoptees (M = 15.68 years at adolescence; M = 24.95 years at emerging adulthood) using semistructured interviews and questionnaires. Structural equation models showed a good fit to sample data, and analyses supported the hypothesized mediation model. Contact with birth relatives is associated with more frequent adoption-related family conversation, which in turn is associated with the development of adoptive identity. These results highlight the importance of supporting activities such as contact that lead to adoption-related family conversation. 2011 APA, all rights reserved

  3. Measurements of conversion factor of the Argonauta reactor

    International Nuclear Information System (INIS)

    Souza, M.I.S.

    1988-01-01

    The conversion factor (Fc) in the Argonauta reactor using uranium target prepared by electrodeposition method, irradiated in the core and in thermal collumn with thermal neutrons flux maximum is studied. Some data obtained through γ radiation emited by U-239 are shown. (M.J.C.) [pt

  4. In-situ measurement of electroosmotic drag coefficient in Nafion membrane for the PEMFC.

    Science.gov (United States)

    Peng, Zhe; Morin, Arnaud; Huguet, Patrice; Schott, Pascal; Pauchet, Joël

    2011-11-10

    A new method based on hydrogen pump has been developed to measure the electroosmotic drag coefficient in representative PEMFC operating conditions. It allows eliminating the back-flow of water which leads to some errors in the calculation of this coefficient with previously reported electrochemical methods. Measurements have been performed on 50 μm thick Nafion membranes both extruded and recast. Contrary to what has been described in most of previous published works, the electroosmotic drag coefficient decreases as the membrane water content increases. The same trend is observed for temperatures between 25 and 80 °C. For the same membrane water content, the electroosmotic drag coefficient increases with temperature. In the same condition, there is no difference in drag coefficient for extruded Nafion N112 and recast Nafion NRE212. These results are discussed on the basis of the two commonly accepted proton transport mechanisms, namely, Grotthus and vehicular.

  5. Numerical study of hydrodynamic behavior and conversion efficiency of a two-buoy wave energy converter

    Science.gov (United States)

    Yang, Cen; Zhang, Yong-liang

    2018-04-01

    In this paper we propose a two-buoy wave energy converter composed of a heaving semi-submerged cylindrical buoy, a fixed submerged cylindrical buoy and a power take-off (PTO) system, and investigate the effect of the fixed submerged buoy on the hydrodynamics of the heaving semi-submerged buoy based on the three-dimensional potential theory. And the dynamic response of the semi-submerged buoy and the wave energy conversion efficiency of the converter are analyzed. The difference of the hydrodynamics and the wave energy conversion efficiency of a semi-submerged buoy converter with and without a fixed submerged buoy is discussed. It is revealed that the influence of the fixed submerged buoy on the exciting wave force, the added mass, the radiation damping coefficient and the wave energy conversion efficiency can be significant with a considerable variation, depending on the vertical distance between the heaving semi-submerged buoy and the fixed submerged buoy, the diameter ratio of the fixed submerged buoy to the heaving semi-submerged buoy and the water depth.

  6. A fast algorithm for computing binomial coefficients modulo powers of two.

    Science.gov (United States)

    Andreica, Mugurel Ionut

    2013-01-01

    I present a new algorithm for computing binomial coefficients modulo 2N. The proposed method has an O(N3·Multiplication(N)+N4) preprocessing time, after which a binomial coefficient C(P, Q) with 0≤Q≤P≤2N-1 can be computed modulo 2N in O(N2·log(N)·Multiplication(N)) time. Multiplication(N) denotes the time complexity of multiplying two N-bit numbers, which can range from O(N2) to O(N·log(N)·log(log(N))) or better. Thus, the overall time complexity for evaluating M binomial coefficients C(P, Q) modulo 2N with 0≤Q≤P≤2N-1 is O((N3+M·N2·log(N))·Multiplication(N)+N4). After preprocessing, we can actually compute binomial coefficients modulo any 2R with R≤N. For larger values of P and Q, variations of Lucas' theorem must be used first in order to reduce the computation to the evaluation of multiple (O(log(P))) binomial coefficients C(P', Q') (or restricted types of factorials P'!) modulo 2N with 0≤Q'≤P'≤2N-1.

  7. Mutual diffusion coefficients of isopropanol + n-heptane and isobutanol + n-heptane

    International Nuclear Information System (INIS)

    He, Maogang; Peng, Sanguo; Zhang, Ying; Zhang, Shi; Liu, Xiangyang

    2016-01-01

    Graphical abstract: Mutual diffusion coefficients of isopropanol + n-heptane as a function of mass fraction of isopropanol. - Highlights: • D_1_2 of isopropanol + n-heptane and isobutanol + n-heptane were measured. • Effect of T, w and M of the solute on D_1_2 were analyzed. • A new correlation is proposed for the experimental data. - Abstract: The mutual diffusion coefficients of isopropanol + n-heptane and isobutanol + n-heptane were measured at different concentrations and in the temperature range from (283.15 to 323.15) K. The measurements were carried out using a digital holographic interferometry system. For all the mixtures investigated, the mutual diffusion coefficient increases as the temperature increases. At the same concentration and temperature, the mutual diffusion coefficients of isobutanol + n-heptane were lower than those of isopropanol + n-heptane due to the fact that the molecular weight of isobutanol is larger than that of isopropanol. A new correlation is proposed for the mutual diffusion coefficients of isopropanol + n-heptane and isobutanol + n-heptane. The absolute average relative deviation between the correlation and experiment is less than 1.90%.

  8. Analyse de Décrire la conversation en ligne : le face à face distanciel

    Directory of Open Access Journals (Sweden)

    Aurélie Bayle

    2012-11-01

    Full Text Available 1. Introduction Décrire la conversation en ligne : le face à face distanciel (2011 met à contribution dix spécialistes de l'analyse des conversations et de la communication médiée par ordinateur. L'idée est inspirée de Décrire la conversation (1987. Cet ouvrage, qui s'inscrivait dans le mouvement interactionniste, s'attachait à décrire de manière détaillée une interaction dans le but d'éclairer différents aspects du fonctionnement d'une conversation. Les données étudiées étaient constituées...

  9. A fluid-solid coupling simulation method for convection heat transfer coefficient considering the under-vehicle condition

    Science.gov (United States)

    Tian, C.; Weng, J.; Liu, Y.

    2017-11-01

    The convection heat transfer coefficient is one of the evaluation indexes of the brake disc performance. The method used in this paper to calculate the convection heat transfer coefficient is a fluid-solid coupling simulation method, because the calculation results through the empirical formula method have great differences. The model, including a brake disc, a car body, a bogie and flow field, was built, meshed and simulated in the software FLUENT. The calculation models were K-epsilon Standard model and Energy model. The working condition of the brake disc was considered. The coefficient of various parts can be obtained through the method in this paper. The simulation result shows that, under 160 km/h speed, the radiating ribs have the maximum convection heat transfer coefficient and the value is 129.6W/(m2·K), the average coefficient of the whole disc is 100.4W/(m2·K), the windward of ribs is positive-pressure area and the leeward of ribs is negative-pressure area, the maximum pressure is 2663.53Pa.

  10. Elements of energy conversion

    CERN Document Server

    Russell, Charles R

    2013-01-01

    Elements of Energy Conversion brings together scattered information on the subject of energy conversion and presents it in terms of the fundamental thermodynamics that apply to energy conversion by any process. Emphasis is given to the development of the theory of heat engines because these are and will remain most important power sources. Descriptive material is then presented to provide elementary information on all important energy conversion devices. The book contains 10 chapters and opens with a discussion of forms of energy, energy sources and storage, and energy conversion. This is foll

  11. Conversion of Reactor LVR-15 in Czech Republic from HEU to LEU Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Broz, V.; Miletic, M.; Koleska, M.; Ernest, J.; Vins, M. [Research Reactors, Research Centre Rez Ltd., Husinec-Rez 130, CZ 250 68 (Czech Republic)

    2011-07-01

    Accordingly to the IAEA recommendations and RERTR program, the LVR-15 reactor started the process of conversion from fuel enriched to 36 % to fuel enriched up to 20 % U{sup 235}. As the most suitable fuel for the reactor was chosen the IRT-4M fuel enriched to 19.7% U{sup 235}, fabricated in NZCHK Novosibirsk. The most important requirements, the fuel had to fulfill, were attainability, constructional continuity with the old type of FAs and operational experiences. The conversion procedure began in January 2010 with testing irradiation of 3 IRT-4M FAs. Test irradiation took 9 reactor operation cycles. During this period were done visual inspection and sipping tests of FAs. An experiment with the aim to compare the influence of the fuel changing to neutron flux and the reactivity and to verify basic physical characteristics of the new fuel was performed at the start of test irradiation. The conversion itself is going on since January 2011. In this time, every cycle will be replaced 1 or 2 burned-up IRT-2M FAs with fresh IRT-4M FAs. This period will take 14 cycles and at the end should be in the core used only IRT-4M fuel. (author)

  12. On the Kendall Correlation Coefficient

    OpenAIRE

    Stepanov, Alexei

    2015-01-01

    In the present paper, we first discuss the Kendall rank correlation coefficient. In continuous case, we define the Kendall rank correlation coefficient in terms of the concomitants of order statistics, find the expected value of the Kendall rank correlation coefficient and show that the later is free of n. We also prove that in continuous case the Kendall correlation coefficient converges in probability to its expected value. We then propose to consider the expected value of the Kendall rank ...

  13. Obtaining the conversion curve of CT numbers to electron density from the effective energy of the CT using the dummy SEFM

    International Nuclear Information System (INIS)

    Martin-Viera Cueto, J. A.; Garcia Pareja, S.; Benitez Villegas, E. M.; Moreno Saiz, E. M.; Bodineau Gil, C.; Caudepon Moreno, F.

    2011-01-01

    The objective of this work is to obtain the conversion curve of Hounsfield units (A) versus electron densities using a mannequin with different tissue equivalent materials. This provides for the effective energy beam CT and is used to characterize the linear coefficients of absorption of different materials that comprise the dummy.

  14. ''Spin-dependent'' μ → e conversion on light nuclei

    International Nuclear Information System (INIS)

    Davidson, Sacha; Saporta, Albert; Kuno, Yoshitaka

    2018-01-01

    The experimental sensitivity to μ → e conversion will improve by four or more orders of magnitude in coming years, making it interesting to consider the ''spin-dependent'' (SD) contribution to the rate. This process does not benefit from the atomic-number-squared enhancement of the spin-independent (SI) contribution, but probes different operators. We give details of our recent estimate of the spin-dependent rate, expressed as a function of operator coefficients at the experimental scale. Then we explore the prospects for distinguishing coefficients or models by using different targets, both in an EFT perspective, where a geometric representation of different targets as vectors in coefficient space is introduced, and also in three leptoquark models. It is found that comparing the rate on isotopes with and without spin could allow one to detect spin-dependent coefficients that are at least a factor of few larger than the spin-independent ones. Distinguishing among the axial, tensor and pseudoscalar operators that induce the SD rate would require calculating the nuclear matrix elements for the second two. Comparing the SD rate on nuclei with an odd proton vs. odd neutron could allow one to distinguish operators involving u quarks from those involving d quarks; this is interesting because the distinction is difficult to make for SI operators. (orig.)

  15. ''Spin-dependent'' μ → e conversion on light nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Sacha; Saporta, Albert [IPNL, CNRS/IN2P3, Villeurbanne (France); Universite Claude Bernard Lyon 1, Villeurbanne (France); Universite de Lyon, Lyon (France); Kuno, Yoshitaka [Osaka University, Department of Physics, Toyonaka, Osaka (Japan)

    2018-02-15

    The experimental sensitivity to μ → e conversion will improve by four or more orders of magnitude in coming years, making it interesting to consider the ''spin-dependent'' (SD) contribution to the rate. This process does not benefit from the atomic-number-squared enhancement of the spin-independent (SI) contribution, but probes different operators. We give details of our recent estimate of the spin-dependent rate, expressed as a function of operator coefficients at the experimental scale. Then we explore the prospects for distinguishing coefficients or models by using different targets, both in an EFT perspective, where a geometric representation of different targets as vectors in coefficient space is introduced, and also in three leptoquark models. It is found that comparing the rate on isotopes with and without spin could allow one to detect spin-dependent coefficients that are at least a factor of few larger than the spin-independent ones. Distinguishing among the axial, tensor and pseudoscalar operators that induce the SD rate would require calculating the nuclear matrix elements for the second two. Comparing the SD rate on nuclei with an odd proton vs. odd neutron could allow one to distinguish operators involving u quarks from those involving d quarks; this is interesting because the distinction is difficult to make for SI operators. (orig.)

  16. A comparison of simple and realistic eye models for calculation of fluence to dose conversion coefficients in a broad parallel beam incident of protons

    International Nuclear Information System (INIS)

    Sakhaee, Mahmoud; Vejdani-Noghreiyan, Alireza; Ebrahimi-Khankook, Atiyeh

    2015-01-01

    Radiation induced cataract has been demonstrated among people who are exposed to ionizing radiation. To evaluate the deterministic effects of ionizing radiation on the eye lens, several papers dealing with the eye lens dose have been published. ICRP Publication 103 states that the lens of the eye may be more radiosensitive than previously considered. Detailed investigation of the response of the lens showed that there are strong differences in sensitivity to ionizing radiation exposure with respect to cataract induction among the tissues of the lens of the eye. This motivated several groups to look deeper into issue of the dose to a sensitive cell population within the lens, especially for radiations with low energy penetrability that have steep dose gradients inside the lens. Two sophisticated mathematical models of the eye including the inner structure have been designed for the accurate dose estimation in recent years. This study focuses on the calculations of the absorbed doses of different parts of the eye using the stylized models located in UF-ORNL phantom and comparison with the data calculated with the reference computational phantom in a broad parallel beam incident of protons with energies between 20 MeV and 10 GeV. The obtained results indicate that the total lens absorbed doses of reference phantom has good compliance with those of the more sensitive regions of stylized models. However, total eye absorbed dose of these models greatly differ with each other for lower energies. - Highlights: • The validation of reference data for the eye was studied for proton exposures. • Two real mathematical models of the eye were imported into the UF-ORNL phantom. • Fluence to dose conversion coefficients were calculated for different eye sections. • Obtained Results were compared with that of assessed by ICRP adult male phantom

  17. Correlation coefficients in neutron β-decay

    International Nuclear Information System (INIS)

    Byrne, J.

    1978-01-01

    The various angular and polarisation coefficients in neutron decay are the principal sources of information on the β-interaction. Measurements of the electron-neutrino angular correlation coefficient (a), the neutron-spin-electron-momentum correlation coefficient (A), the neutron-spin-neutrino-momentum correlation coefficient (B), and the triple correlation coefficient D and time-reversal invariance are reviewed and the results discussed. (U.K.)

  18. Investigation of Wear Coefficient of Manganese Phosphate Coated Tool Steel

    Directory of Open Access Journals (Sweden)

    S. Ilaiyavel

    2013-03-01

    Full Text Available In recent years the properties of the coating in terms of wear resistance is of paramount importance in order to prevent the formation of severe damages. In this study, Wear coefficient of uncoated, Manganese Phosphate coated, Manganese Phosphate coated with oil lubricant, Heat treated Manganese Phosphate coated with oil lubricant on AISI D2 steels was investigated using Archard’s equation. The wear tests were performed in a pin on disk apparatus as per ASTM G-99 Standard. The volumetric wear loss and wear coefficient were evaluated through pin on disc test using a sliding velocity of 3.0 m/s under normal load of 40 N and controlled condition of temperature and humidity. Based on the results of the wear test, the Heat treated Manganese Phosphate with oil lubricant exhibited the lowest average wear coefficient and the lowest wear loss under 40 N load.

  19. Feasibility study of internal conversion electron spectroscopy of {sup 229m}Th

    Energy Technology Data Exchange (ETDEWEB)

    Seiferle, Benedict; Wense, Lars von der; Thirolf, Peter G. [Ludwig-Maximilians-Universitaet Muenchen, Garching (Germany)

    2017-05-15

    With an expected energy of 7.8(5) eV, the isomeric first excited state in {sup 229}Th exhibits the lowest excitation energy of all known nuclei. Until today, a value for the excitation energy has been inferred only by indirect measurements. In this paper we propose an experimental method that is potentially capable of measuring the ground-state transition energy via the detection of the internal conversion electrons. MatLab-based Monte Carlo simulations have been performed to obtain an estimate of the expected statistics and to test the feasibility and the expected precision of the experiment. From the simulations we conclude that with the presented methods an energy determination with a precision of better than 0.1 eV is within reach. (orig.)

  20. High-performance alternating current field-induced chromatic-stable white polymer electroluminescent devices employing a down-conversion layer

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Yingdong; Chen, Yonghua; Smith, Gregory M. [Center for Nanotechnology and Molecular Materials, Department of Physics, Wake Forest University, Winston-Salem, NC 27105 (United States); Sun, Hengda; Yang, Dezhi [State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Nie, Wanyi; Li, Yuan; Huang, Wenxiao [Center for Nanotechnology and Molecular Materials, Department of Physics, Wake Forest University, Winston-Salem, NC 27105 (United States); Ma, Dongge [State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Carroll, David L., E-mail: carroldl@wfu.edu [Center for Nanotechnology and Molecular Materials, Department of Physics, Wake Forest University, Winston-Salem, NC 27105 (United States)

    2015-05-15

    In this work, a high-performance alternating current (AC) filed-induced chromatic-stable white polymer electroluminescence (WFIPEL) device was fabricated by combining a fluorophor Poly(9,9-dioctylfluorene) (PFO)-based blue device with a yellow down-conversion layer (YAG:Ce). A maximum luminance of this down-conversion FIPEL device achieves 3230 cd m{sup −2}, which is 1.41 times higher than the device without the down-conversion layer. A maximum current efficiency and power efficiency of the down-conversion WFIPEL device reach 19.7 cd A{sup −1} at 3050 cd m{sup −2} and 5.37 lm W{sup −1} at 2310 cd m{sup −2} respectively. To the best of our knowledge, the power efficiency is one of the highest reports for the WFIPEL up to now. Moreover, Commison Internationale de L’Eclairage (CIE) coordinates of (0.28, 0.30) is obtained by adjusting the thickness of the down-conversion layer to 30 μm and it is kept stable over the entire AC-driven voltage range. We believe that this AC-driven, down-conversion, WFIPEL device may offer an easy way towards future flat and flexible lighting sources. - Highlights: • A high-performance AC filed-induced chromatic-stable white polymer electroluminescence (WFIPEL) device was fabricated. • A maximum luminance, current efficiency, and power efficiency achieves 3230 cd m{sup −2}, 19.7 cd A{sup −1}, and 5.37 lm W{sup −1}, respectively. • The power efficiency is one of the highest reports for the WFIPEL up to now. • The EL spectrum kept very stable over the entire AC-driven voltage range.

  1. Correlation of the Auger electrons direction of movement with the internal electron conversion direction of movement

    International Nuclear Information System (INIS)

    Mitrokhovich, N.F.; Kupryashkin, V.T.; Sidorenko, L.P.

    2013-01-01

    On installation of coincidences of γ-quanta with electrons and with law energy electrons about zero area the spatial correlation of the direction emitting Auger-electrons and electron of internal conversion was investigated at the 152 Eu decay. Auger-electrons were registered on e 0 -electrons of the secondary electron emission (γ e IC e 0 -coincidences). It was established, that Auger-electrons of M-series, as well as electrons 'shake-off' at β-decay and internal conversion, are strongly correlated at the direction of movement with the direction of movement of basic particle (β -particle, conversion electron), moving together mainly in the forward hemisphere. The intensity of correlated M-Auger radiation in range energy 1000 - 1700 eV is equal to intensity of correlated radiation 'shake-off' electron from internal conversion in this range. The assumption, that the presence of spatial correlating Auger-electron and conversion electron caused by cur-rent components of electron-electron interaction of particles in the final state is made

  2. Heterogeneous conversion of NO2 on secondary organic aerosol surfaces: A possible source of nitrous acid (HONO in the atmosphere?

    Directory of Open Access Journals (Sweden)

    R. Bröske

    2003-01-01

    Full Text Available The heterogeneous conversion of NO2 on different secondary organic aerosols (SOA was investigated with the focus on a possible formation of nitrous acid (HONO. In one set of experiments different organic aerosols were produced in the reactions of O3 with alpha-pinene, limonene or catechol and OH radicals with toluene or limonene, respectively. The aerosols were sampled on filters and exposed to humidified NO2  mixtures under atmospheric conditions. The estimated upper limits for the uptake coefficients of NO2  and the reactive uptake coefficients NO2  -> HONO are in the range of 10-6 and 10-7, respectively. The integrated HONO formation for 1 h reaction time was 13 cm-2 geometrical surface and 17 g-1 particle mass. In a second set of experiments the conversion of NO2 into HONO in the presence of organic particles was carried out in an aerosol flow tube under atmospheric conditions. In this case the aerosols were produced in the reaction of O3 with beta-pinene, limonene or catechol, respectively. The upper limits for the reactive uptake coefficients NO2 -> HONO were in the range of 7 x 10-7 - 9 x 10-6. The results from the present study show that heterogeneous formation of nitrous acid on secondary organic aerosols (SOA is unimportant for the atmosphere.

  3. Iterated multidimensional wave conversion

    International Nuclear Information System (INIS)

    Brizard, A. J.; Tracy, E. R.; Johnston, D.; Kaufman, A. N.; Richardson, A. S.; Zobin, N.

    2011-01-01

    Mode conversion can occur repeatedly in a two-dimensional cavity (e.g., the poloidal cross section of an axisymmetric tokamak). We report on two novel concepts that allow for a complete and global visualization of the ray evolution under iterated conversions. First, iterated conversion is discussed in terms of ray-induced maps from the two-dimensional conversion surface to itself (which can be visualized in terms of three-dimensional rooms). Second, the two-dimensional conversion surface is shown to possess a symplectic structure derived from Dirac constraints associated with the two dispersion surfaces of the interacting waves.

  4. Design and implementation of a versatile and variable-frequency piezoelectric coefficient measurement system.

    Science.gov (United States)

    Wu, J S; Huang, Y K; Wu, F L; Lin, D Y

    2012-08-01

    We present a simple but versatile piezoelectric coefficient measurement system, which can measure the longitudinal and transverse piezoelectric coefficients in the pressing and bending modes, respectively, at different applied forces and a wide range of frequencies. The functionality of this measurement system has been demonstrated on three samples, including a PbZr(0.52)Ti(0.48)O(3) (PZT) piezoelectric ceramic bulk, a ZnO thin film, and a laminated piezoelectric film sensor. The static longitudinal piezoelectric coefficients of the PZT bulk and the ZnO film are estimated to be around 210 and 8.1 pC/N, respectively. The static transverse piezoelectric coefficients of the ZnO film and the piezoelectric film sensor are determined to be, respectively, -0.284 and -0.031 C/m(2).

  5. Estimation of radon emanation coefficient for soil and flyash

    International Nuclear Information System (INIS)

    Sahu, S.K.; Swarnkar, M.; Ajmal, P.Y.; Pandit, G.G.; Puranik, V.D.

    2012-01-01

    Since terrestrial materials include radium ( 226 Ra) originating from the decay of uranium ( 238 U), all such materials release radon ( 222 Rn) to varying degrees. When a radium atom decays to radon, the energy generated is strong enough to send the radon atom a distance of about 40 nanometers-this is known as alpha recoil. For a radon atom to escape the radium atom must be within the recoil distance from the grain surface of flyash or soil and the direction of recoil must send the radon atom toward the outside of the grain. Therefore, all of the radon atoms generated by the radium contained in flyash or soil grain are actually not released into pore spaces and mobilized. The fraction of radon atoms generated from radium decay that are released from into flyash or soil pore space is defined as the radon emanation coefficient or emanating power, of the material. Grain size and shape are two of the important factors that control the radon emanation coefficient because they determine in part how much uranium and radium is near enough to the surface of the grain to allow the newly-formed radon to escape into a pore space. In a porous medium, where the radon is in radioactive equilibrium with its parent radium, the emanation coefficient is given by the expression: where C 0 is the undiluted radon activity concentration in the pores of the medium, and C Ra is the radium activity concentration of the sample. The 226 Ra activity concentration of the flyash and soil sample were determined by using the g-spectrometry. C 0 was determined by the can experiment using LR-115 for flyash and soil samples. The C 0 values for flyash and soil samples were found to be 245.7 Bq/m 3 and 714.3 Bq/m 3 respectively. The radon emanation coefficient for flyash was found to be 0.0024 while that for soil was 0.0092. Therefore the soil sample was found to be four times higher radon emanation coefficient than flyash which is in line with the results reported in the literatures. This may suggest

  6. Agreement and conversion formula between mini-mental state examination and montreal cognitive assessment in an outpatient sample.

    Science.gov (United States)

    Helmi, Luqman; Meagher, David; O'Mahony, Edmond; O'Neill, Donagh; Mulligan, Owen; Murthy, Sutha; McCarthy, Geraldine; Adamis, Dimitrios

    2016-09-22

    To explore the agreement between the mini-mental state examination (MMSE) and montreal cognitive assessment (MoCA) within community dwelling older patients attending an old age psychiatry service and to derive and test a conversion formula between the two scales. Prospective study of consecutive patients attending outpatient services. Both tests were administered by the same researcher on the same day in random order. The total sample (n = 135) was randomly divided into two groups. One to derive a conversion rule (n = 70), and a second (n = 65) in which this rule was tested. The agreement (Pearson's r) of MMSE and MoCA was 0.86 (P < 0.001), and Lin's concordance correlation coefficient (CCC) was 0.57 (95%CI: 0.45-0.66). In the second sample MoCA scores were converted to MMSE scores according to a conversion rule from the first sample which achieved agreement with the original MMSE scores of 0.89 (Pearson's r, P < 0.001) and CCC of 0.88 (95%CI: 0.82-0.92). Although the two scales overlap considerably, the agreement is modest. The conversion rule derived herein demonstrated promising accuracy and warrants further testing in other populations.

  7. Estimating temperature reactivity coefficients by experimental procedures combined with isothermal temperature coefficient measurements and dynamic identification

    International Nuclear Information System (INIS)

    Tsuji, Masashi; Aoki, Yukinori; Shimazu, Yoichiro; Yamasaki, Masatoshi; Hanayama, Yasushi

    2006-01-01

    A method to evaluate the moderator coefficient (MTC) and the Doppler coefficient through experimental procedures performed during reactor physics tests of PWR power plants is proposed. This method combines isothermal temperature coefficient (ITC) measurement experiments and reactor power transient experiments at low power conditions for dynamic identification. In the dynamic identification, either one of temperature coefficients can be determined in such a way that frequency response characteristics of the reactivity change observed by a digital reactivity meter is reproduced from measured data of neutron count rate and the average coolant temperature. The other unknown coefficient can also be determined by subtracting the coefficient obtained from the dynamic identification from ITC. As the proposed method can directly estimate the Doppler coefficient, the applicability of the conventional core design codes to predict the Doppler coefficient can be verified for new types of fuels such as mixed oxide fuels. The digital simulation study was carried out to show the feasibility of the proposed method. The numerical analysis showed that the MTC and the Doppler coefficient can be estimated accurately and even if there are uncertainties in the parameters of the reactor kinetics model, the accuracies of the estimated values are not seriously impaired. (author)

  8. Field estimation of the utilization coefficient of added inorganic nitrogen by sugar-beets

    International Nuclear Information System (INIS)

    Lindemann, Y.; Guiraud, G.; Christmann, J.; Auge, G.

    1981-07-01

    Fertilization with mineral nitrogen labelled with the 15 isotope permits, in the crop, the estimation of both: - the real utilization coefficient of N fertilizer, - the uptake of the available N issued from organic matter. In 1979, such an experiment was carried out on sugar beet in Beauce on a long term field experiment including 7 N.P.K. treatments with 4 repetitions. Each plot was divided into 2 parts to constitute a treatment N=0 for the estimation of the apparent utilization coefficient. In addition, 4 microplots (size: 8 m 2 ) received a labelled fertilizer for the measurement of the actual coefficients. The results obtained show the incoherence of the apparent coefficients, which are higher than 100%. The real coefficients are from 40 to 80%. Thus, the balance sheet for the input and output of mineral nitrogen is established precisely. The gross mineralization can be much more important than the net mineralization [fr

  9. Pade approximants for entire functions with regularly decreasing Taylor coefficients

    International Nuclear Information System (INIS)

    Rusak, V N; Starovoitov, A P

    2002-01-01

    For a class of entire functions the asymptotic behaviour of the Hadamard determinants D n,m as 0≤m≤m(n)→∞ and n→∞ is described. This enables one to study the behaviour of parabolic sequences from Pade and Chebyshev tables for many individual entire functions. The central result of the paper is as follows: for some sequences {(n,m(n))} in certain classes of entire functions (with regular Taylor coefficients) the Pade approximants {π n,m(n) }, which provide the locally best possible rational approximations, converge to the given function uniformly on the compact set D={z:|z|≤1} with asymptotically best rate

  10. Research on friction coefficient of nuclear Reactor Vessel Internals Hold Down Spring: Stress coefficient test analysis method

    International Nuclear Information System (INIS)

    Linjun, Xie; Guohong, Xue; Ming, Zhang

    2016-01-01

    Graphical abstract: HDS stress coefficient test apparatus. - Highlights: • This paper performs mathematic deduction to the physical model of Hold Down Spring (HDS), establishes a mathematic model of axial load P and stress, stress coefficient and friction coefficient and designs a set of test apparatuses for simulating the pretightening process of the HDS for the first time according to a model similarity criterion. • The mathematical relation between the load and the strain is obtained about the HDS, and the mathematical model of the stress coefficient and the friction coefficient is established. So, a set of test apparatuses for obtaining the stress coefficient is designed according to the model scaling criterion and the friction coefficient of the K1000 HDS is calculated to be 0.336 through the obtained stress coefficient. • The relation curve between the theoretical load and the friction coefficient is obtained through analysis and indicates that the change of the friction coefficient f would influence the pretightening load under the condition of designed stress. The necessary pretightening load in the design process is calculated to be 5469 kN according to the obtained friction coefficient. Therefore, the friction coefficient and the pretightening load under the design conditions can provide accurate pretightening data for the analysis and design of the reactor HDS according to the operations. - Abstract: This paper performs mathematic deduction to the physical model of Hold Down Spring (HDS), establishes a mathematic model of axial load P and stress, stress coefficient and friction coefficient and designs a set of test apparatuses for simulating the pretightening process of the HDS for the first time according to a model similarity criterion. By carrying out tests and researches through a stress testing technique, P–σ curves in loading and unloading processes of the HDS are obtained and the stress coefficient k f of the HDS is obtained. So, the

  11. Research on friction coefficient of nuclear Reactor Vessel Internals Hold Down Spring: Stress coefficient test analysis method

    Energy Technology Data Exchange (ETDEWEB)

    Linjun, Xie, E-mail: linjunx@zjut.edu.cn [College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310014 (China); Guohong, Xue; Ming, Zhang [Shanghai Nuclear Engineering Research & Design Institute, Shanghai 200233 (China)

    2016-08-01

    Graphical abstract: HDS stress coefficient test apparatus. - Highlights: • This paper performs mathematic deduction to the physical model of Hold Down Spring (HDS), establishes a mathematic model of axial load P and stress, stress coefficient and friction coefficient and designs a set of test apparatuses for simulating the pretightening process of the HDS for the first time according to a model similarity criterion. • The mathematical relation between the load and the strain is obtained about the HDS, and the mathematical model of the stress coefficient and the friction coefficient is established. So, a set of test apparatuses for obtaining the stress coefficient is designed according to the model scaling criterion and the friction coefficient of the K1000 HDS is calculated to be 0.336 through the obtained stress coefficient. • The relation curve between the theoretical load and the friction coefficient is obtained through analysis and indicates that the change of the friction coefficient f would influence the pretightening load under the condition of designed stress. The necessary pretightening load in the design process is calculated to be 5469 kN according to the obtained friction coefficient. Therefore, the friction coefficient and the pretightening load under the design conditions can provide accurate pretightening data for the analysis and design of the reactor HDS according to the operations. - Abstract: This paper performs mathematic deduction to the physical model of Hold Down Spring (HDS), establishes a mathematic model of axial load P and stress, stress coefficient and friction coefficient and designs a set of test apparatuses for simulating the pretightening process of the HDS for the first time according to a model similarity criterion. By carrying out tests and researches through a stress testing technique, P–σ curves in loading and unloading processes of the HDS are obtained and the stress coefficient k{sub f} of the HDS is obtained. So, the

  12. Calibration of ionization chamber and GM counter survey meters, (1)

    International Nuclear Information System (INIS)

    Bingo, Kazuyoshi; Kajimoto, Yoichi; Suga, Shin-ichi

    1978-01-01

    Three types of ionization chamber survey meters and a type of GM counter survey meter were calibrated for measuring the β-ray absorbed dose rate in a working area. To estimate the β-ray absorbed dose rate, a survey meter was used without and with a filter. A reading of survey meter's indicator measured with the filter was subtracted from a reading measured without the filter, and then the absorbed dose rate was obtained by multiplying this remainder by a conversion coefficient. The conversion coefficients were roughly constant with distance more than 8 cm (ionization chamber survey meters) and with distance more than 5 cm (GM counter survey meter). The conversion coefficient was dependent on β-ray energies. In order to measure the absorbed dose rate of tissue whose epidermal thickness is 40 mg/cm 2 , the constant value, 4 (mrad/h)/(mR/h), was chosen independently of β-ray energies as the conversion coefficient of three types of ionization chamber survey meters. The conversion coefficient of the GM counter survey meter was more energy dependent than that of every type of ionization chamber survey meter. (author)

  13. Study on Millimeter-Wave Vivaldi Rectenna and Arrays with High Conversion Efficiency

    Directory of Open Access Journals (Sweden)

    Guan-Nan Tan

    2016-01-01

    Full Text Available A novel Vivaldi rectenna operated at 35 GHz with high millimeter wave to direct current (MMW-to-DC conversion efficiency is presented and the arrays are investigated. The measured conversion efficiency is 51.6% at 35 GHz and the efficiency higher than 30% is from 33.2 GHz to 36.6 GHz when the input MMW power is 79.4 mW. The receiving Vivaldi antenna loaded with metamaterial units has a high gain of 10.4 dBi at 35 GHz. A SIW- (substrate integrated waveguide- to-microstrip transition is designed not only to integrate the antenna with the rectifying circuit directly but also to provide the DC bypass for the rectifying circuit. When the power density is 8.7 mW/cm2, the received MMW power of the antenna is 5.6 mW, and the maximum conversion efficiency of the rectenna element is 31.5%. The output DC voltage of the element is nearly the same as that of the parallel array and is about half of the series array. The DC power obtained by the 1 × 2 rectenna arrays is about two times as much as that of the element. The conversion efficiencies of the arrays are very close to that of the element. Large scale arrays could be expended for collecting more DC power.

  14. Transfer coefficients of radionuclides from feed to livestock products

    International Nuclear Information System (INIS)

    1995-03-01

    The accumulation of data on radionuclide transfer are poor in Japan and those are limited to 90 Sr, 137 Cs and 131 I released from the previous atomic bomb experiments. However, in Europe, intensive studies on environment RI level which affects the restriction of the intake for meats and milk products have been made as the measures against the environment radioactivity due to Chernobyl accident. The transfer coefficients of radionuclides to meats and milk products were estimated on a basis of the data published in the Science of the Total Environment vol.85(1989), Oxford University and CEC Radiation Protection, EUR 12608 EN, Luxembourg, 1990 in addition to the data on Exclusion of Radioactivity from foods, Environment Parameter, series No. 4. On the other hand, the transfer coefficients for Japanese were estimated using the concerned data from published reports and the environment radioactivity data reported by national and local government bodies. In this book, many new data of transfer coefficient are presented in tables along with the previous data collected by international nuclear energy agencies and respective national facilities concerned. (M.N.)

  15. Study of distribution coefficients of admixtures in tellurium

    International Nuclear Information System (INIS)

    Kuchar, L.; Drapala, J.; Kuchar, L. jr.

    1986-01-01

    Limit areas of tellurium-admixture binary systems were studied and the values determined of steady-state distribution coefficients of admixtures. A second order polynomial was used to express equations of solidus and liquidus curves for Te-Se, Te-S, Te-Hg systems; the curves are graphically represented. The most effective method for preparing high-purity tellurium is zonal melting with material removal. (M.D.). 4 figs., 4 tabs., 16 refs

  16. Conversion of tritiated hydrogen to tritiated water on heated metal surfaces

    International Nuclear Information System (INIS)

    Dickson, R.S.

    1993-05-01

    The conversion of tritium to tritiated water on metal surfaces was studied under conditions relevant to releases into a fusion reactor hall (metal temperatures between 473 K and 623 K, air or inert gas atmospheres). The rate constant of oxidation per unit geometric surface area was found to be about a factor of ten higher than the rate constant per unit gas adsorption surface area for H 2 to H 2 O conversion on metal oxides in excess oxygen, probably because of the roughness of the metal surfaces on a gas adsorption scale. Surface roughness and oxides were found to have a major influence on the reaction rate. The reaction exhibited a first-order dependence on Q 2 concentration. Changing the dew point of the atmosphere did not affect the rate significantly, and rate constants for most metals were independent of whether the atmosphere was argon or air. Coatings of hydrocarbon and silicone polymers did not significantly affect the reaction rate on carbon steel and ferrous metals and brass all had about the same conversion rate constant. Aluminum alloy gave about three times lower and copper in Ar gave ten times higher conversion rate constants. Based on these data, an accident scenario involving exposure of 1000 m 2 of stainless steel at 573 K to a 10 4 m 3 room would cause conversion of ca. 0.1% of the Q 2 present to Q 2 O in 24 hours, while air ingress to the torus without leakage of the tritium into the room would cause 1.2% conversion in that time. The rate values are only accurate within a multiplicative factor of three, so they should be applied cautiously in model calculations. (author). 27 refs., 4 tabs., 4 figs

  17. Measuring of heat transfer coefficient

    DEFF Research Database (Denmark)

    Henningsen, Poul; Lindegren, Maria

    Subtask 3.4 Measuring of heat transfer coefficient Subtask 3.4.1 Design and setting up of tests to measure heat transfer coefficient Objective: Complementary testing methods together with the relevant experimental equipment are to be designed by the two partners involved in order to measure...... the heat transfer coefficient for a wide range of interface conditions in hot and warm forging processes. Subtask 3.4.2 Measurement of heat transfer coefficient The objective of subtask 3.4.2 is to determine heat transfer values for different interface conditions reflecting those typically operating in hot...

  18. Clustering Coefficients for Correlation Networks

    Directory of Open Access Journals (Sweden)

    Naoki Masuda

    2018-03-01

    Full Text Available Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients

  19. Clustering Coefficients for Correlation Networks.

    Science.gov (United States)

    Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu

    2018-01-01

    Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly

  20. Clustering Coefficients for Correlation Networks

    Science.gov (United States)

    Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu

    2018-01-01

    Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly

  1. Giant Magnetoelectric Energy Conversion Utilizing Inter-Ferroelectric Phase Transformations in Ferroics

    Science.gov (United States)

    Finkel, Peter; Staruch, Margo

    Phase transition-based electromechanical transduction permits achieving a non-resonant broadband mechanical energy conversion see (Finkel et al Actuators, 5 [1] 2. (2015)) , the idea is based on generation high energy density per cycle , at least 100x of magnitude larger than linear piezoelectric type generators in stress biased [011]cut relaxor ferroelectric Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 (PIN-PMN-PT) single crystal can generate reversible strain >0.35% at remarkably low fields (0.1 MV/m) for tens of millions of cycles. Recently we demonstrated that large strain and polarization rotation can be generated for over 40 x 106cycles with little fatigue by realization of reversible ferroelectric-ferroelectric phase transition in [011] cut PIN-PMN-PT relaxor ferroelectric single crystal while sweeping through the transition with a low applied electric field <0.18 MV/m under mechanical stress. This methodology was extended in the present work to propose magnetoelectric (ME) composite hybrid system comprised of highly magnetostrictive alloymFe81.4Ga18.6 (Galfenol), and lead indium niobate-lead magnesium niobate-lead titanate (PIN-PMN-PT) domain engineered relaxor ferroelectric single crystal. A small time-varying magnetic field applied to this system causes the magnetostrictive element to expand, and the resulting stress forces the phase change in the relaxor ferroelectric single crystal. ME coupling coefficient was fond to achieve 80 V/cm Oe near the FR-FO phase transition that is at least 100X of magnitude higher than any currently reported values.

  2. New method and installation for rapid determination of radon diffusion coefficient in various materials

    International Nuclear Information System (INIS)

    Tsapalov, Andrey; Gulabyants, Loren; Livshits, Mihail; Kovler, Konstantin

    2014-01-01

    The mathematical apparatus and the experimental installation for the rapid determination of radon diffusion coefficient in various materials are developed. The single test lasts not longer than 18 h and allows testing numerous materials, such as gaseous and liquid media, as well as soil, concrete and radon-proof membranes, in which diffusion coefficient of radon may vary in an extremely wide range, from 1·10 −12 to 5·10 −5 m 2 /s. The uncertainty of radon diffusion coefficient estimation depends on the permeability of the sample and varies from about 5% (for the most permeable materials) to 40% (for less permeable materials, such as radon-proof membranes). - Highlights: • The new method and installation for determination of radon diffusion coefficient D are developed. • The measured D-values vary in an extremely wide range, from 5×10 -5 to 1×10 -12 m 2 /s. • The materials include water, air, soil, building materials and radon-proof membranes. • The duration of the single test does not exceed 18 hours. • The measurement uncertainty varies from 5% (in permeable materials) to 40% (in radon gas barriers)

  3. Implications of next generation attenuation ground motion prediction equations for site coefficients used in earthquake resistant design

    Science.gov (United States)

    Borcherdt, Roger D.

    2014-01-01

    Proposals are developed to update Tables 11.4-1 and 11.4-2 of Minimum Design Loads for Buildings and Other Structures published as American Society of Civil Engineers Structural Engineering Institute standard 7-10 (ASCE/SEI 7–10). The updates are mean next generation attenuation (NGA) site coefficients inferred directly from the four NGA ground motion prediction equations used to derive the maximum considered earthquake response maps adopted in ASCE/SEI 7–10. Proposals include the recommendation to use straight-line interpolation to infer site coefficients at intermediate values of (average shear velocity to 30-m depth). The NGA coefficients are shown to agree well with adopted site coefficients at low levels of input motion (0.1 g) and those observed from the Loma Prieta earthquake. For higher levels of input motion, the majority of the adopted values are within the 95% epistemic-uncertainty limits implied by the NGA estimates with the exceptions being the mid-period site coefficient, Fv, for site class D and the short-period coefficient, Fa, for site class C, both of which are slightly less than the corresponding 95% limit. The NGA data base shows that the median value  of 913 m/s for site class B is more typical than 760 m/s as a value to characterize firm to hard rock sites as the uniform ground condition for future maximum considered earthquake response ground motion estimates. Future updates of NGA ground motion prediction equations can be incorporated easily into future adjustments of adopted site coefficients using procedures presented herein. 

  4. Form of multicomponent Fickian diffusion coefficients matrix

    International Nuclear Information System (INIS)

    Wambui Mutoru, J.; Firoozabadi, Abbas

    2011-01-01

    Highlights: → Irreversible thermodynamics establishes form of multicomponent diffusion coefficients. → Phenomenological coefficients and thermodynamic factors affect sign of diffusion coefficients. → Negative diagonal elements of diffusion coefficients matrix can occur in non-ideal mixtures. → Eigenvalues of the matrix of Fickian diffusion coefficients may not be all real. - Abstract: The form of multicomponent Fickian diffusion coefficients matrix in thermodynamically stable mixtures is established based on the form of phenomenological coefficients and thermodynamic factors. While phenomenological coefficients form a symmetric positive definite matrix, the determinant of thermodynamic factors matrix is positive. As a result, the Fickian diffusion coefficients matrix has a positive determinant, but its elements - including diagonal elements - can be negative. Comprehensive survey of reported diffusion coefficients data for ternary and quaternary mixtures, confirms that invariably the determinant of the Fickian diffusion coefficients matrix is positive.

  5. Changes of the temperature coefficients of the characteristics which accompany degradation and recovery of a-Si solar cells; A-Si taiyo denchi no hikari (denryu) rekka oyobi kaifuku ni tomonau tokusei ondo keisu no henka

    Energy Technology Data Exchange (ETDEWEB)

    Yanagisawa, T; Koyanagi, T; Nakamura, K; Takahisa, K; Kojima, T [electrotechnical Laboratory, Tsukuba (Japan)

    1996-10-27

    Pursuant to the measuring of temperature dependency of the characteristics such as conversion efficiency, during the process of degradation in a-Si solar cells due to light and electric current and the process of recovery by annealing, this paper describes changes in temperature coefficients, correlation between the characteristic parameters and the degradation, and the results of the examination of their characteristics. The conversion efficiency {mu} degraded approximately by 45% of the initial value each by the irradiation under a light intensity with 3 SUN accelerated and by the infusion of current at 20mA/cm{sup 2}; and then, the efficiency recovered to 70-75% of the degradation by subsequent annealing. In addition, in the temperature dependency at 80{degree}C against at 20{degree}C, Isc slightly increased while Vcc greatly decreased. This slight increase in Isc was mainly due to the decrease in the width of the forbidden band, while the decrease in Vcc was due to the increase in the reverse saturation current. The temperature dependency of {mu}N was negative, becoming small in accordance with the degradation. The temperature dependency of FF/FFO was negative initially both in light and current, but it decreased with the degradation and turned to positive. The temperature coefficients of I-V parameters reversibly changed corresponding to the degradation and recovery of these parameters and stayed in a good correlation. 7 refs., 8 figs., 1 tab.

  6. Statistical Analysis of Manning's roughness Coefficients in Non-vegetated Canals for Irrigation and Drainage Network of Moghan

    Directory of Open Access Journals (Sweden)

    Abolfazl Nasseri

    2017-03-01

    Full Text Available Introduction: Due to sensitiveness of flow to roughness coefficient (RC, selection of this coefficient is important in earth canals designing purposes. Precision selection of this coefficient is necessary for design and operation of earthen canals purposes. Overestimation of the actual amount of this coefficient will cause an underestimation for flow velocity. Accordingly, sedimentation in the earth canals will reduce canals’ capacitances. Adversely, underestimation of this coefficient will cause an overestimation for flow velocity and water flux in the earth canals. It will also increase the risk of soil erosion in the channels. This coefficient is expressed by Manning, Chezy and Darcy Weisbach equations. While, hydraulic engineers have selected Manning equation to estimate the flow rate in open channels due to ease of use and acceptable precision in the application of this equation. Water for crop production in Moghan, as one of the most important agricultural centers in Iran, is supplied from Moghan-Meel diversion dam via main canal of irrigation and drainage network with a capacity of 80 m3 s-1 with a length of 116 km. All of the branched 63-channel from the main channel are earthen. Continual sedimentation in the earth canals reduced the capacity of them and re-estimation the capacity of this canals needs to the precise quantities of variables such as roughness coefficient. Because the overestimation of the actual value of the coefficient would reduce the canals’ capacity and underestimation of the coefficient increase the risk of erosion in earth canals. The analysis of the correlation among variables, regression, analysis of statistical distribution of variables, analysis of variance of variables and the analysis of the events probabilities for stochastic variables can be made by statistical methods. Therefore, these methods were applied to analysis of roughness coefficient in the earth canals. Also, due to the importance of roughness

  7. Spectral Dependence of the Scattering Coefficient in Case 1 and Case 2 Waters

    Science.gov (United States)

    Gould, Richard W., Jr.; Arnone, Robert A.; Martinolich, Paul M.

    1999-04-01

    An approximate linear relationship between the scattering coefficient and the wavelength of light in the visible is found in case 1 and case 2 waters. From this relationship, we estimate scattering at an unknown wavelength from scattering at a single measured wavelength. This approximation is based on measurements in a 1.5-m-thick surface layer collected with an AC9 instrument at 63 stations in the Arabian Sea, northern Gulf of Mexico, and coastal North Carolina. The light-scattering coefficient at 412 nm ranged from 0.2 to 15.1 m 1 in these waters, and the absorption coefficient at 412 nm ranged from 0.2 to 4.0 m 1 . A separate data set for 100 stations from Oceanside, California, and Chesapeake Bay, Virginia, was used to validate the relationship. Although the Oceanside waters were considerably different from the developmental data set (based on absorption-to-scattering ratios and single-scattering albedos), the average error between modeled and measured scattering values was 6.0% for the entire test data set over all wavelengths (without regard to sign). The slope of the spectral scattering relationship decreases progressively from high-scattering, turbid waters dominated by suspended sediments to lower-scattering, clear waters dominated by phytoplankton.

  8. Infrared up-conversion microscope

    DEFF Research Database (Denmark)

    2014-01-01

    There is presented an up-conversion infrared microscope (110) arranged for imaging an associated object (130), wherein the up-conversion infrared microscope (110) comprises a non-linear crystal (120) arranged for up-conversion of infrared electromagnetic radiation, and wherein an objective optical...

  9. Infrared up-conversion telescope

    DEFF Research Database (Denmark)

    2014-01-01

    There is presented to an up-conversion infrared telescope (110) arranged for imaging an associated scene (130), wherein the up-conversion infrared telescope (110) comprises a non-linear crystal (120) arranged for up-conversion of infrared electromagnetic radiation, and wherein a first optical...

  10. Ventilation coefficient trends in the recent decades over four major ...

    Indian Academy of Sciences (India)

    viz., Mumbai, Delhi, Kolkata and Chennai is analysed to study the trends and long term ... terized by their economic development and large ... in ventilation coefficient over different regions in. India as ... VC trends in recent decades over major Indian Metropolitan cities ..... M 2009 A case study of atmospheric boundary layer.

  11. Research Note On New Limits of the Coefficient of Gravitation ...

    Indian Academy of Sciences (India)

    Research Note. On New Limits of the Coefficient of Gravitation Shielding. Michele Caputo. Physics Department, University La Sapienza, Piazzale A. Moro 2, 00185 Roma, Italy. and. Department of Geology and Geophysics, Texas A&M University, College Station TX, 77843,. USA. e-mail: mcaputo@g24ux.phys.uniroma1.it.

  12. Estimates for the Aerodynamic Coefficients of Ringsail and Disk-Gap-Band Parachutes Operating on Mars

    Science.gov (United States)

    Cruz, Juan R.; Snyder, Miranda L.

    2017-01-01

    Models are presented for the aerodynamic coefficients of Supersonic Ringsail and Disk-Gap-Band parachutes as functions of total porosity, Lambda(sub t), Mach number, M, and total angle of attack, Alpha(sub t) (when necessary). The source aerodynamic coefficients data used for creating these models were obtained from a wind tunnel test of subscale parachutes. In this wind tunnel test, subscale parachutes of both parachute types were fabricated from two different fabrics with very different permeabilities. By varying the fabric permeability, while maintaining the parachute geometry constant, it was possible to vary Alpha(sub t). The fabric permeability test data necessary for the calculation of Alpha(sub t) were obtained from samples of the same fabrics used to fabricate the subscale parachutes. Although the models for the aerodynamic coefficients are simple polynomial functions of Alpha(sub t) and M, they are capable of producing good reproductions of the source data. The (Alpha(sub t), M) domains over which these models are applicable are clearly defined. The models are applicable to flight operations on Mars.

  13. A Model for Conversation

    DEFF Research Database (Denmark)

    Ayres, Phil

    2012-01-01

    This essay discusses models. It examines what models are, the roles models perform and suggests various intentions that underlie their construction and use. It discusses how models act as a conversational partner, and how they support various forms of conversation within the conversational activity...

  14. Change in Biot's effective stress coefficient of chalk during pore collapse

    DEFF Research Database (Denmark)

    Alam, M. Monzurul; Fabricius, Ida Lykke

    2013-01-01

    the grains could also change during elastic deformation of the grains in a rock mechanics test. Diagenetic change in grain contact cement of chalk can be compared with stress-induced change in the laboratory. The change in porosity is studied with reference to the change in effective stress on grain contacts...... and porosity reduces at a slower rate. We noticed that presence of non carbonates and hydrocarbon could increase σ'm. During rock mechanics test in the lab, with increased applied stress, σ'm increases, Biot's effective stress coefficient shows a decreasing trend, while a minor porosity reduction was observed......Biot's effective stress coefficient (α) is a measure of how well grains in the rocks are connected with each other. The amount of contact cements between the grains determines the stiffness of rocks. Change in grain contact occurs during natural diagenesis of sedimentary rock. Contact between...

  15. Absolute M1 and E2 Transition Probabilities in 233U

    International Nuclear Information System (INIS)

    Malmskog, S.G.; Hoejeberg, M.

    1967-08-01

    Using the delayed coincidence technique, the following half lives have been determined for different excited states in 233 U: T 1/2 (311.9 keV level) = (1.20 ± 0.15) x 10 -10 sec, T 1/2 (340.5 keV level) = (5.2 ± 1.0) x 10 -11 sec, T 1/2 (398.6 keV level) = (5.5 ± 2.0) x 10 -11 sec and T 1/2 (415.8 keV level) -11 sec. From these half life determinations, together with earlier known electron intensities and conversion coefficients, 22 reduced B(Ml) and B(E2) transition probabilities (including 9 limits) have been deduced. The rotational transitions give information on the parameters δ and (g K - g R ) . The experimental M1 and E2 transition rates between members of different bands have been analysed in terms of the predictions of the Nilsson model, taking also pairing correlations and Coriolis coupling effects into account

  16. Transition-metal chlorides as conversion cathode materials for Li-ion batteries

    International Nuclear Information System (INIS)

    Li Ting; Chen, Zhong X.; Cao, Yu L.; Ai, Xin P.; Yang, Han X.

    2012-01-01

    Insoluble AgCl and soluble CuCl 2 were selected and investigated as model compounds of transition-metal chlorides for electrochemical conversion cathode materials. The experimental results demonstrated that the AgCl nanocrystals can convert reversibly to metallic Ag with nearly full utilization of its one-electron redox capacity (187 mAh g −1 ). Similarly, the CuCl 2 -filled mesoporous carbon can realize a reversible two-electron transfer reaction, giving a very high reversible capacity of 466 mAh g −1 after 20 cycles. These data imply that the metal chlorides can undergo complete electrochemical conversion utilizing their full oxidation states for electrical energy storage as previously reported metal fluorides, possibly being used as high capacity cathode materials for Li-ion batteries.

  17. Recent progress on the calculation of three-loop heavy flavor Wilson coefficients in deep-inelastic scattering

    International Nuclear Information System (INIS)

    Ablinger, J.; Hasselhuhn, A.; Schneider, C.; Behring, A.; Bluemlein, J.; Freitas, A. de; Raab, C.; Round, M.; Manteuffel, A. von

    2014-07-01

    We report on our latest results in the calculation of the three-loop heavy flavor contributions to the Wilson coefficients in deep-inelastic scattering in the asymptotic region Q 2 >>m 2 . We discuss the different methods used to compute the required operator matrix elements and the corresponding Feynman integrals. These methods very recently allowed us to obtain a series of new operator matrix elements and Wilson coefficients like the flavor non-singlet and pure singlet Wilson coefficients.

  18. CT- and MRI-based volumetry of resected liver specimen: Comparison to intraoperative volume and weight measurements and calculation of conversion factors

    International Nuclear Information System (INIS)

    Karlo, C.; Reiner, C.S.; Stolzmann, P.; Breitenstein, S.; Marincek, B.; Weishaupt, D.; Frauenfelder, T.

    2010-01-01

    Objective: To compare virtual volume to intraoperative volume and weight measurements of resected liver specimen and calculate appropriate conversion factors to reach better correlation. Methods: Preoperative (CT-group, n = 30; MRI-group, n = 30) and postoperative MRI (n = 60) imaging was performed in 60 patients undergoing partial liver resection. Intraoperative volume and weight of the resected liver specimen was measured. Virtual volume measurements were performed by two readers (R1,R2) using dedicated software. Conversion factors were calculated. Results: Mean intraoperative resection weight/volume: CT: 855 g/852 mL; MRI: 872 g/860 mL. Virtual resection volume: CT: 960 mL(R1), 982 mL(R2); MRI: 1112 mL(R1), 1115 mL(R2). Strong positive correlation for both readers between intraoperative and virtual measurements, mean of both readers: CT: R = 0.88(volume), R = 0.89(weight); MRI: R = 0.95(volume), R = 0.92(weight). Conversion factors: 0.85(CT), 0.78(MRI). Conclusion: CT- or MRI-based volumetry of resected liver specimen is accurate and recommended for preoperative planning. A conversion of the result is necessary to improve intraoperative and virtual measurement correlation. We found 0.85 for CT- and 0.78 for MRI-based volumetry the most appropriate conversion factors.

  19. The influence of the atmosphere on geoid and potential coefficient determinations from gravity data

    Science.gov (United States)

    Rummel, R.; Rapp, R. H.

    1976-01-01

    For the precise computation of geoid undulations the effect of the attraction of the atmosphere on the solution of the basic boundary value problem of gravimetric geodesy must be considered. This paper extends the theory of Moritz for deriving an atmospheric correction to the case when the undulations are computed by combining anomalies in a cap surrounding the computation point with information derived from potential coefficients. The correction term is a function of the cap size and the topography within the cap. It reaches a value of 3.0 m for a cap size of 30 deg, variations on the decimeter level being caused by variations in the topography. The effect of the atmospheric correction terms on potential coefficients is found to be small, reaching a maximum of 0.0055 millionths at n = 2, m = 2 when terrestrial gravity data are considered. The magnitude of this correction indicates that in future potential coefficient determination from gravity data the atmospheric correction should be made to such data.

  20. Determination of first Townsend coefficient in pure isobutane

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Iara B.; Vivaldini, Tulio C.; Goncalves, Josemary A.C.; Botelho, Suzana; Tobias, Carmen C.B. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Ridenti, Marco A.; Pascholati, Paulo R. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica. Lab. do Acelerador Linear; Fonte, Paulo; Mangiarotti, Alessio [Universidade de Coimbra (Portugal). Dept. de Fisica. Lab. de Instrumentacao e Fisica Experimental de Particulas

    2010-07-01

    Full text. Electron transport parameters in gases play an important role for detector design, discharge modelling and validation of the electron impact cross-sections involved. Recently, the experiments in high energy physics and the development of gaseous detectors operating in high electric fields have motivated the determination of these parameters in gases with complex structure. This work presents measurements of first Townsend coefficient (alpha) in pure isobutane, choosing due to its importance for the development of gaseous detectors. The measurements were obtained with a parallel plate chamber, protected against discharges by the anode made of a high resistivity ({rho} = 2 x 10{sup 10} {Omega}{center_dot}m) glass plate (32.5 x 32.5mm{sup 2}). The experimental method is based on the Pulsed Townsend technique, where the primary ionization is produced through the incidence of a nitrogen laser beam (MNL202-LD LTB) onto the cathode (40mm diameter) made of aluminum. The electrons released drift toward the anode under the electric field applied through a high voltage power supply (225-30R Bertan). This charges movement produces an electric current which is measured by an electrometer (610C Keithley), directly connected to the cathode. Considering the solution of the Townsend equation for uniform electric fields, from the ratio between the current measured in avalanche regime (I) and the primary ionization current (I{sub 0}), the first Townsend coefficient can be determined, since {alpha} = d{sup -1} In(I/I{sub 0}), where d is the gap between the electrodes. The validation of the technique was provided by measurements of first Townsend coefficient in pure nitrogen, a widely studied gas, which has well-established data in literature. The alpha coefficient in isobutane was measured as a function of the reduced electric field in the range of 139Td up to 208Td (1Td = 1 x 10{sup 21} V.m{sup 2}). The obtained values were compared with those simulated by Imonte code

  1. Determination of first Townsend coefficient in pure isobutane

    International Nuclear Information System (INIS)

    Lima, Iara B.; Vivaldini, Tulio C.; Goncalves, Josemary A.C.; Botelho, Suzana; Tobias, Carmen C.B.; Ridenti, Marco A.; Pascholati, Paulo R.; Fonte, Paulo; Mangiarotti, Alessio

    2010-01-01

    Full text. Electron transport parameters in gases play an important role for detector design, discharge modelling and validation of the electron impact cross-sections involved. Recently, the experiments in high energy physics and the development of gaseous detectors operating in high electric fields have motivated the determination of these parameters in gases with complex structure. This work presents measurements of first Townsend coefficient (alpha) in pure isobutane, choosing due to its importance for the development of gaseous detectors. The measurements were obtained with a parallel plate chamber, protected against discharges by the anode made of a high resistivity (ρ = 2 x 10 10 Ω·m) glass plate (32.5 x 32.5mm 2 ). The experimental method is based on the Pulsed Townsend technique, where the primary ionization is produced through the incidence of a nitrogen laser beam (MNL202-LD LTB) onto the cathode (40mm diameter) made of aluminum. The electrons released drift toward the anode under the electric field applied through a high voltage power supply (225-30R Bertan). This charges movement produces an electric current which is measured by an electrometer (610C Keithley), directly connected to the cathode. Considering the solution of the Townsend equation for uniform electric fields, from the ratio between the current measured in avalanche regime (I) and the primary ionization current (I 0 ), the first Townsend coefficient can be determined, since α = d -1 In(I/I 0 ), where d is the gap between the electrodes. The validation of the technique was provided by measurements of first Townsend coefficient in pure nitrogen, a widely studied gas, which has well-established data in literature. The alpha coefficient in isobutane was measured as a function of the reduced electric field in the range of 139Td up to 208Td (1Td = 1 x 10 21 V.m 2 ). The obtained values were compared with those simulated by Imonte code (version 4.5) and the only experimental results available

  2. Operational impacts of low-enrichment uranium fuel conversion on the Ford Nuclear Reactor

    International Nuclear Information System (INIS)

    Bernal, F.E.; Brannon, C.C.; Burgard, N.E.; Burn, R.R.; Cook, G.M.; Simpson, P.A.

    1985-01-01

    The University of Michigan Department of Nuclear Engineering and the Michigan Memorial-Phoenix Project have been engaged in a cooperative effort with Argonne National Laboratory to test and analyze low-enrichment fuel in the Ford Nuclear Reactor (FNR). The effort was begun in 1979, as part of the Reduced Enrichment Research and Test Reactor Program, to demonstrate on a whole-core basis the feasibility of enrichment reduction from 93% to <20% in Materials Test Reactor-type fuel designs. The first low-enrichment uranium (LEU) core was loaded into the FNR and criticality was achieved on December 8, 1981. The final LEU core was established October 11, 1984. No significant operational impacts have resulted from conversion of the FNR to LEU fuel. Thermal flux in the core has decreased slightly; thermal leakage flux has increased. Rod worths, temperature coefficient, and void coefficient have changed imperceptibly. Impressions from the operators are that power defect has increased slightly and that fuel lifetime has increased

  3. Post-test analysis of components from selenide isotope generator modules M-7, M-15, and M-18

    International Nuclear Information System (INIS)

    Wei, G.C.; Keiser, J.R.; Crouse, R.S.; Allen, M.D.; Schaffhauser, A.C.

    1979-05-01

    Several critical components removed from SIG (Selenide Isotope Generator) thermoelectric modules M-7, M-15C, M-15D, and M-18 were examined. These modules failed to show the predicted stability and conversion efficiency. Understanding the degradation and identifying means for preventing it necessitated detailed post-test examinations of key parts in the modules. Steel springs, which provided pressure for contacts at the hot and cold ends of P- or N-legs, relaxed more than expected. Beryllium oxide insulators had dark deposits that caused electrical shorts. The GdSe 1 49 N-leg exhibited cracking. The (Cu,Ag) 2 Se P-leg lost weight or sublimed excessively in module M-7 and more than expected in the other modules

  4. Talking theory of mind talk: young school-aged children's everyday conversation and understanding of mind and emotion.

    Science.gov (United States)

    De Rosnay, Marc; Fink, Elian; Begeer, Sander; Slaughter, Virginia; Peterson, Candida

    2014-09-01

    Links between young children's everyday use of mindful conversational skills and their success on laboratory tests of theory of mind understanding (ToM) were evaluated. Using published scales, teachers rated the conversational behavior and shyness of 129 children aged 60 to 101 months (M = 78·8 months) who were in their first years of primary school. The children also took batteries of first- and second-order false-belief tests along with tests of emotion understanding and general language ability. Correlational and regression analyses showed that performance on false-belief tests of ToM significantly predicted children's competence at reading others' minds in their everyday conversational interactions. Furthermore, these links transcended individual differences in language ability, shy personality, emotion understanding, and age. These findings augment and extend a growing body of evidence linking performance on laboratory ToM tests to socially competent real-world behavior.

  5. Sample size for estimation of the Pearson correlation coefficient in cherry tomato tests

    Directory of Open Access Journals (Sweden)

    Bruno Giacomini Sari

    2017-09-01

    Full Text Available ABSTRACT: The aim of this study was to determine the required sample size for estimation of the Pearson coefficient of correlation between cherry tomato variables. Two uniformity tests were set up in a protected environment in the spring/summer of 2014. The observed variables in each plant were mean fruit length, mean fruit width, mean fruit weight, number of bunches, number of fruits per bunch, number of fruits, and total weight of fruits, with calculation of the Pearson correlation matrix between them. Sixty eight sample sizes were planned for one greenhouse and 48 for another, with the initial sample size of 10 plants, and the others were obtained by adding five plants. For each planned sample size, 3000 estimates of the Pearson correlation coefficient were obtained through bootstrap re-samplings with replacement. The sample size for each correlation coefficient was determined when the 95% confidence interval amplitude value was less than or equal to 0.4. Obtaining estimates of the Pearson correlation coefficient with high precision is difficult for parameters with a weak linear relation. Accordingly, a larger sample size is necessary to estimate them. Linear relations involving variables dealing with size and number of fruits per plant have less precision. To estimate the coefficient of correlation between productivity variables of cherry tomato, with a confidence interval of 95% equal to 0.4, it is necessary to sample 275 plants in a 250m² greenhouse, and 200 plants in a 200m² greenhouse.

  6. Measurement of activity coefficients of mixtures by head-space gas chromatography: general procedure.

    Science.gov (United States)

    Luis, Patricia; Wouters, Christine; Van der Bruggen, Bart; Sandler, Stanley I

    2013-08-09

    Head-space gas chromatography (HS-GC) is an applicable method to perform vapor-liquid equilibrium measurements and determine activity coefficients. However, the reproducibility of the data may be conditioned by the experimental procedure concerning to the automated pressure-balanced system. The study developed in this work shows that a minimum volume of liquid in the vial is necessary to ensure the reliability of the activity coefficients since it may become a parameter that influences the magnitude of the peak areas: the helium introduced during the pressurization step may produce significant variations of the results when too small volume of liquid is selected. The minimum volume required should thus be evaluated prior to obtain experimentally the concentration in the vapor phase and the activity coefficients. In this work, the mixture acetonitrile-toluene is taken as example, requiring a sample volume of more than 5mL (about more than 25% of the vial volume). The vapor-liquid equilibrium and activity coefficients of mixtures at different concentrations (0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9 molar fraction) and four temperatures (35, 45, 55 and 70°C) have been determined. Relative standard deviations (RSD) lower than 5% have been obtained, indicating the good reproducibility of the method when a sample volume larger than 5mL is used. Finally, a general procedure to measure activity coefficients by means of pressure-balanced head-space gas chromatography is proposed. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Bacterial degradation of m-nitrobenzoic acid.

    OpenAIRE

    Nadeau, L J; Spain, J C

    1995-01-01

    Pseudomonas sp. strain JS51 grows on m-nitrobenzoate (m-NBA) with stoichiometric release of nitrite. m-NBA-grown cells oxidized m-NBA and protocatechuate but not 3-hydroxybenzoate, 4-hydroxy-3-nitrobenzoate, 4-nitrocatechol, and 1,2,4-benzenetriol. Protocatechuate accumulated transiently when succinate-grown cells were transferred to media containing m-NBA. Respirometric experiments indicated that the conversion of m-NBA to protocatechuate required 1 mol of oxygen per mol of substrate. Conver...

  8. A new methodology for determining dispersion coefficient using ordinary and partial differential transport equations.

    Science.gov (United States)

    Cho, Kyung Hwa; Lee, Seungwon; Ham, Young Sik; Hwang, Jin Hwan; Cha, Sung Min; Park, Yongeun; Kim, Joon Ha

    2009-01-01

    The present study proposes a methodology for determining the effective dispersion coefficient based on the field measurements performed in Gwangju (GJ) Creek in South Korea which is environmentally degraded by the artificial interferences such as weirs and culverts. Many previous works determining the dispersion coefficient were limited in application due to the complexity and artificial interferences in natural stream. Therefore, the sequential combination of N-Tank-In-Series (NTIS) model and Advection-Dispersion-Reaction (ADR) model was proposed for evaluating dispersion process in complex stream channel in this study. The series of water quality data were intensively monitored in the field to determine the effective dispersion coefficient of E. coli in rainy day. As a result, the suggested methodology reasonably estimates the dispersion coefficient for GJ Creek with 1.25 m(2)/s. Also, the sequential combined method provided Number of tank-Velocity-Dispersion coefficient (NVD) curves for convenient evaluation of dispersion coefficient of other rivers or streams. Comparing the previous studies, the present methodology is quite general and simple for determining the effective dispersion coefficients which are applicable for other rivers and streams.

  9. Convective Heat Transfer Coefficients of the Human Body under Forced Convection from Ceiling

    DEFF Research Database (Denmark)

    Kurazumi, Yoshihito; Rezgals, Lauris; Melikov, Arsen Krikor

    2014-01-01

    The average convective heat transfer coefficient for a seated human body exposed to downward flow from above was determined. Thermal manikin with complex body shape and size of an average Scandinavian female was used. The surface temperature distribution of the manikin’s body was as the skin...... of the convective heat transfer coefficient of the whole body (hc [W/(m2•K)]) was proposed: hc=4.088+6.592V1.715 for a seated naked body at 20ºC and hc=2.874+7.427V1.345 for a seated naked body at 26ºC. Differences in the convective heat transfer coefficient of the whole body in low air velocity range, V

  10. Mycobacterium abscessus subsp. abscessus Lung Disease: Drug Susceptibility Testing in Sputum Culture Negative Conversion

    Directory of Open Access Journals (Sweden)

    Takehiko Kobayashi

    2018-01-01

    Full Text Available Background: Among Mycobacterium abscessus complex infections, patients with M. abscessus subsp. abscessus (MAA lung disease are difficult to treat and no standard therapy has been established. Few reports have investigated the drug susceptibility of these strains. We retrospectively investigated how in vitro drug susceptibility testing (DST of MAA affects the induction of sputum conversion using pharmacotherapy. Methods: Patients with MAA lung disease diagnosed and treated between 2010 and 2014 at our hospital were enrolled and divided into Group A (sputum conversion without relapse within 1 year and Group B (persistent positive cultured or negative conversion with relapse. MAA was identified in M. abscessus using sequence with genotyping, and DST of MAA was performed. Results: We assessed 23 patients (9 males and 14 females. There were 8 patients in Group A and 15 in Group B. Higher prevalence of susceptible isolates for clarithromycin (CAM susceptibility on day 14 was noted in Group A than in Group B (P = 0.03 and no significant difference observed in the two groups for other drugs. Conclusions: In vitro DST of MAA, especially CAM susceptibility on day 14, affected the results of negative conversion. No other drugs were found to affect sputum culture negative conversion.

  11. Four questions and a conversation: Can theory enrich conversation partner training?

    DEFF Research Database (Denmark)

    Pound, Carole; Ahlsén, Elisabeth; Simmons-Mackie, NIna

    Background and aimsConversation partner training (CPT) is an umbrella term for different approaches to intervention aiming to facilitate and improve communication between people with aphasia (PWA) and their conversation partners (CP). Some approaches are grounded in a bottom-up approach...... and interactions. Philosophically informed by existential-phenomenological perspectives, the humanisation framework encourages reflection on what practices can make people feel more (or less) human. Reviewing experiences of conversation against the eight suggested dimensions of what it means to be human may offer...

  12. Direct Conversion of Energy.

    Science.gov (United States)

    Corliss, William R.

    This publication is one of a series of information booklets for the general public published by the United States Atomic Energy Commission. Direct energy conversion involves energy transformation without moving parts. The concepts of direct and dynamic energy conversion plus the laws governing energy conversion are investigated. Among the topics…

  13. Mode conversions by a discontinuous junction of two helix loaded waveguides

    International Nuclear Information System (INIS)

    Choe, J.Y.; Ahn, S.; Ganquly, A.K.; Uhm, H.S.

    1983-01-01

    For various reasons, it is desirable to vary the primary propagating mode from one section of the waveguide to another. We choose the base structure to be the sheath helix loaded waveguide. Specifically, we join two physically different helix loaded waveguides axisymmetrically, thereby providing the required discontinuities at the junction (Z = 0). The helix loaded waveguide is more advantageous to the simple waveguide in that the helix mode that exists uniquely in the helix waveguide in addition to the usual fast wave hybrid modes, is without cutoff and thus behaves like a transmission line. In order to obtain the mode conversion rates, we expand the waves in the both sides of the junction with its own eigenmodes including the evanescent modes, and by matching fields at the junction (Z = 0) obtain the matrix equation for the coefficients for the eigenmodes in both sides. By choosing the propagating incident wave (Z = 0) the resulting outgoing waves in the other end (Z > 0) will be computed from the matrix equation. A computer program is devised to solve the suitably truncated matrix equation, and the numerical examples for the mode conversion rates with the parameter variations will be presented. The relevant physical parameters to yield discontinuities at the junction are the radii of the outer conductor and the helix wire and the pitch angle of the helix. Special emphases are on the conversion rates from the helix mode (Z 0) for the application to the tapered gyrotron amplifier

  14. Bottom friction models for shallow water equations: Manning’s roughness coefficient and small-scale bottom heterogeneity

    Science.gov (United States)

    Dyakonova, Tatyana; Khoperskov, Alexander

    2018-03-01

    The correct description of the surface water dynamics in the model of shallow water requires accounting for friction. To simulate a channel flow in the Chezy model the constant Manning roughness coefficient is frequently used. The Manning coefficient nM is an integral parameter which accounts for a large number of physical factors determining the flow braking. We used computational simulations in a shallow water model to determine the relationship between the Manning coefficient and the parameters of small-scale perturbations of a bottom in a long channel. Comparing the transverse water velocity profiles in the channel obtained in the models with a perturbed bottom without bottom friction and with bottom friction on a smooth bottom, we constructed the dependence of nM on the amplitude and spatial scale of perturbation of the bottom relief.

  15. Photon energy conversion by near-zero permittivity nonlinear materials

    Science.gov (United States)

    Luk, Ting S.; Sinclair, Michael B.; Campione, Salvatore

    2017-12-19

    Efficient harmonic light generation can be achieved with ultrathin films by coupling an incident pump wave to an epsilon-near-zero (ENZ) mode of the thin film. As an example, efficient third harmonic generation from an indium tin oxide nanofilm (.lamda./42 thick) on a glass substrate for a pump wavelength of 1.4 .mu.m was demonstrated. A conversion efficiency of 3.3.times.10.sup.-6 was achieved by exploiting the field enhancement properties of the ENZ mode with an enhancement factor of 200. This nanoscale frequency conversion method is applicable to other plasmonic materials and reststrahlen materials in proximity of the longitudinal optical phonon frequencies.

  16. Discrete parametric band conversion in silicon for mid-infrared applications.

    Science.gov (United States)

    Tien, En-Kuang; Huang, Yuewang; Gao, Shiming; Song, Qi; Qian, Feng; Kalyoncu, Salih K; Boyraz, Ozdal

    2010-10-11

    Silicon photonics has great potential for mid-wave-infrared applications. The dispersion of waveguide can be manipulated by waveguide dimension and cladding materials. Simulation shows that <3 μm wide conversion can be achieved by tuning the pump wavelength.

  17. Transport Coefficients of Fluids

    CERN Document Server

    Eu, Byung Chan

    2006-01-01

    Until recently the formal statistical mechanical approach offered no practicable method for computing the transport coefficients of liquids, and so most practitioners had to resort to empirical fitting formulas. This has now changed, as demonstrated in this innovative monograph. The author presents and applies new methods based on statistical mechanics for calculating the transport coefficients of simple and complex liquids over wide ranges of density and temperature. These molecular theories enable the transport coefficients to be calculated in terms of equilibrium thermodynamic properties, and the results are shown to account satisfactorily for experimental observations, including even the non-Newtonian behavior of fluids far from equilibrium.

  18. Semiconductor Nanowires and Nanotubes for Energy Conversion

    Science.gov (United States)

    Fardy, Melissa Anne

    In recent years semiconductor nanowires and nanotubes have garnered increased attention for their unique properties. With their nanoscale dimensions comes high surface area and quantum confinement, promising enhancements in a wide range of applications. 1-dimensional nanostructures are especially attractive for energy conversion applications where photons, phonons, and electrons come into play. Since the bohr exciton radius and phonon and electron mean free paths are on the same length scales as nanowire diameters, optical, thermal, and electrical properties can be tuned by simple nanowire size adjustments. In addition, the high surface area inherent to nanowires and nanotubes lends them towards efficient charge separation and superior catalytic performance. In thermoelectric power generation, the nanoscale wire diameter can effectively scatter phonons, promoting reductions in thermal conductivity and enhancements in the thermoelectric figure of merit. To that end, single-crystalline arrays of PbS, PbSe, and PbTe nanowires have been synthesized by a chemical vapor transport approach. The electrical and thermal transport properties of the nanowires were characterized to investigate their potential as thermoelectric materials. Compared to bulk, the lead chalcogenide nanowires exhibit reduced thermal conductivity below 100 K by up to 3 orders of magnitude, suggesting that they may be promising thermoelectric materials. Smaller diameters and increased surface roughness are expected to give additional enhancements. The solution-phase synthesis of PbSe nanowires via oriented attachment of nanoparticles enables facile surface engineering and diameter control. Branched PbSe nanowires synthesized by this approach showed near degenerately doped charge carrier concentrations. Compared to the bulk, the PbSe nanowires exhibited a similar Seebeck coefficient and a significant reduction in thermal conductivity in the temperature range 20 K to 300 K. Thermal annealing of the Pb

  19. Recent progress on the calculation of three-loop heavy flavor Wilson coefficients in deep-inelastic scattering

    Energy Technology Data Exchange (ETDEWEB)

    Ablinger, J.; Hasselhuhn, A.; Schneider, C. [Johannes Kepler Univ., Linz (Austria). Research Inst. for Symbolic Computation (RISC); Behring, A.; Bluemlein, J.; Freitas, A. de; Raab, C.; Round, M. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Manteuffel, A. von [Mainz Univ. (Germany). PRISMA Cluster of Excellence; Wissbrock, F. [Johannes Kepler Univ., Linz (Austria). Research Inst. for Symbolic Computation (RISC); Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); IHES Institut des Hautes Etudes Scientifiques, Bures-sur-Yvette (France)

    2014-07-15

    We report on our latest results in the calculation of the three-loop heavy flavor contributions to the Wilson coefficients in deep-inelastic scattering in the asymptotic region Q{sup 2}>>m{sup 2}. We discuss the different methods used to compute the required operator matrix elements and the corresponding Feynman integrals. These methods very recently allowed us to obtain a series of new operator matrix elements and Wilson coefficients like the flavor non-singlet and pure singlet Wilson coefficients.

  20. High conversion heavy water moderated reactor

    International Nuclear Information System (INIS)

    Miyawaki, Yoshio; Wakabayashi, Toshio.

    1989-01-01

    In the present invention, fuel rods using uranium-plutonium oxide mixture fuels are arranged in a square lattice at the same pitch as that in light water cooled reactor and heavy water moderators are used. Accordingly, the volume ratio (Vm/Vf) between the moderator and the fuel can be, for example, of about 2. When heavy water is used for the moderator (coolant), since the moderating effect of heavy water is lower than that of light water, a high conversion ratio of not less than 0.8 can be obtained even if the fuel rod arrangement is equal to that of PWR (Vm/Vf about 2). Accordingly, it is possible to avoid problems caused by dense arrangement of fuel rods as in high conversion rate light water cooled reactors. That is, there are no more troubles in view of thermal hydrodynamic characteristics, re-flooding upon loss of coolant accident, etc., as well as the fuel production cost is not increased. (K.M.)

  1. Energy conversion statics

    CERN Document Server

    Messerle, H K; Declaris, Nicholas

    2013-01-01

    Energy Conversion Statics deals with equilibrium situations and processes linking equilibrium states. A development of the basic theory of energy conversion statics and its applications is presented. In the applications the emphasis is on processes involving electrical energy. The text commences by introducing the general concept of energy with a survey of primary and secondary energy forms, their availability, and use. The second chapter presents the basic laws of energy conversion. Four postulates defining the overall range of applicability of the general theory are set out, demonstrating th

  2. Uranium Conversion & Enrichment

    Energy Technology Data Exchange (ETDEWEB)

    Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-06

    The isotopes of uranium that are found in nature, and hence in ‘fresh’ Yellowcake’, are not in relative proportions that are suitable for power or weapons applications. The goal of conversion then is to transform the U3O8 yellowcake into UF6. Conversion and enrichment of uranium is usually required to obtain material with enough 235U to be usable as fuel in a reactor or weapon. The cost, size, and complexity of practical conversion and enrichment facilities aid in nonproliferation by design.

  3. Freely flowing conversations

    DEFF Research Database (Denmark)

    Aakjær, Marie Kirstejn; Andrade, David; Dexters, Peter

    and in regards to rehabilitation efforts. In the context of prisons UDI is inspired by the complexity approach (Stacey 2005). We seek to facilitate freely flowing conversations between inmates, staff and managers – pushing the boundaries of existing norms, roles and beliefs. In the end however we rely...... relations by changing conversations. Through the theoretical framework of the complexity approach, we discuss how this may lead to organizational change. Finally we suggest that inviting inmates to take part in conversations about core organizational development may be a fundamental strategy in trying...

  4. Heat transfer coefficient: Medivance Arctic Sun Temperature Management System vs. water immersion.

    Science.gov (United States)

    English, M J; Hemmerling, T M

    2008-07-01

    To improve heat transfer, the Medivance Arctic Sun Temperature Management System (Medivance, Inc., Louisville, CO, USA) features an adhesive, water-conditioned, highly conductive hydrogel pad for intimate skin contact. This study measured and compared the heat transfer coefficient (h), i.e. heat transfer efficiency, of this pad (hPAD), in a heated model and in nine volunteers' thighs; and of 10 degrees C water (hWATER) in 33 head-out immersions by 11 volunteers. Volunteer studies had ethical approval and written informed consent. Calibrated heat flux transducers measured heat flux (W m-2). Temperature gradient (DeltaT) was measured between skin and pad or water temperatures. Temperature gradient was changed through the pad's water temperature controller or by skin cooling on immersion. The heat transfer coefficient is the slope of W m-2/DeltaT: its unit is W m-2 degrees C-1. Average with (95% CI) was: model, hPAD = 110.4 (107.8-113.1), R2 = 0.99, n = 45; volunteers, hPAD = 109.8 (95.5-124.1), R2 = 0.83, n = 51; and water immersion, hWATER = 107.1 (98.1-116), R2 = 0.86, n = 94. The heat transfer coefficient for the pad was the same in the model and volunteers, and equivalent to hWATER. Therefore, for the same DeltaT and heat transfer area, the Arctic Sun's heat transfer rate would equal water immersion. This has important implications for body cooling/rewarming rates.

  5. Political conversations on Facebook

    DEFF Research Database (Denmark)

    Sørensen, Mads P.

    2016-01-01

    Political conversations are according to theories on deliberative democracy essential to well-functioning democracies. Traditionally these conversations have taken place in face-to-face settings, in e.g. party meetings and town meetings. However, social media such as Facebook and Twitter offers new...... possibilities for online political conversations between citizens and politicians. This paper examines the presence on Facebook and Twitter of Members of the Danish national Parliament, the Folketing, and focusses on a quantitative mapping of the political conversation activities taking place in the threads...... following Facebook posts from Danish Members of Parliament (MPs). The paper shows that, in comparison with previous findings from other countries, Danish MPs have a relatively high degree of engagement in political conversations with citizens on Facebook – and that a large number of citizens follow MPs...

  6. Energy coefficients for a propeller series

    DEFF Research Database (Denmark)

    Olsen, Anders Smærup

    2004-01-01

    The efficiency for a propeller is calculated by energy coefficients. These coefficients are related to four types of losses, i.e. the axial, the rotational, the frictional, and the finite blade number loss, and one gain, i.e. the axial gain. The energy coefficients are derived by use...... of the potential theory with the propeller modelled as an actuator disk. The efficiency based on the energy coefficients is calculated for a propeller series. The results show a good agreement between the efficiency based on the energy coefficients and the efficiency obtained by a vortex-lattice method....

  7. [Conversation analysis for improving nursing communication].

    Science.gov (United States)

    Yi, Myungsun

    2007-08-01

    Nursing communication has become more important than ever before because quality of nursing services largely depends on the quality of communication in a very competitive health care environment. This article was to introduce ways to improve nursing communication using conversation analysis. This was a review study on conversation analysis, critically examining previous studies in nursing communication and interpersonal relationships. This study provided theoretical backgrounds and basic assumptions of conversation analysis which was influenced by ethnomethodology, phenomenology, and sociolinguistic. In addition, the characteristics and analysis methods of conversation analysis were illustrated in detail. Lastly, how conversation analysis could help improve communication was shown, by examining researches using conversation analysis not only for ordinary conversations but also for extraordinary or difficult conversations such as conversations between patients with dementia and their professional nurses. Conversation analysis can help in improving nursing communication by providing various structures and patterns as well as prototypes of conversation, and by suggesting specific problems and problem-solving strategies in communication.

  8. A drying coefficient for building materials

    DEFF Research Database (Denmark)

    Scheffler, Gregor Albrecht; Plagge, Rudolf

    2009-01-01

    coefficient is defined which can be determined based on measured drying data. The correlation of this coefficient with the water absorption and the vapour diffusion coefficient is analyzed and its additional information content is critically challenged. As result, a drying coefficient has been derived......The drying experiment is an important element of the hygrothermal characterisation of building materials. Contrary to other moisture transport experiments as the vapour diffusion and the water absorption test, it is until now not possible to derive a simple coefficient for the drying. However......, in many cases such a coefficient would be highly appreciated, e.g. in interaction of industry and research or for the distinction and selection of suitable building materials throughout design and practise. This article first highlights the importance of drying experiments for hygrothermal...

  9. DFT-INDO/S modeling of new high molar extinction coefficient charge-transfer sensitizers for solar cell applications.

    Science.gov (United States)

    Nazeeruddin, Mohammad K; Wang, Qing; Cevey, Le; Aranyos, Viviane; Liska, Paul; Figgemeier, Egbert; Klein, Cedric; Hirata, Narukuni; Koops, Sara; Haque, Saif A; Durrant, James R; Hagfeldt, Anders; Lever, A B P; Grätzel, Michael

    2006-01-23

    A new ruthenium(II) complex, tetrabutylammonium [ruthenium (4-carboxylic acid-4'-carboxylate-2,2'-bipyridine)(4,4'-di(2-(3,6-dimethoxyphenyl)ethenyl)-2,2'-bipyridine)(NCS)(2)] (N945H), was synthesized and characterized by analytical, spectroscopic, and electrochemical techniques. The absorption spectrum of the N945H sensitizer is dominated by metal-to-ligand charge-transfer (MLCT) transitions in the visible region, with the lowest allowed MLCT bands appearing at 25 380 and 18 180 cm(-1). The molar extinction coefficients of these bands are 34 500 and 18 900 M(-1) cm(-1), respectively, and are significantly higher when compared to than those of the standard sensitizer cis-dithiocyanatobis(4,4'-dicarboxylic acid-2,2'-bipyridine)ruthenium(II). An INDO/S and density functional theory study of the electronic and optical properties of N945H and of N945 adsorbed on TiO(2) was performed. The calculations point out that the top three frontier-filled orbitals have essentially ruthenium 4d (t(2g) in the octahedral group) character with sizable contribution coming from the NCS ligand orbitals. Most critically the calculations reveal that, in the TiO(2)-bound N945 sensitizer, excitation directs charge into the carboxylbipyridine ligand bound to the TiO(2) surface. The photovoltaic data of the N945 sensitizer using an electrolyte containing 0.60 M butylmethylimidazolium iodide, 0.03 M I(2), 0.10 M guanidinium thiocyanate, and 0.50 M tert-butylpyridine in a mixture of acetonitrile and valeronitrile (volume ratio = 85:15) exhibited a short-circuit photocurrent density of 16.50 +/- 0.2 mA cm(-2), an open-circuit voltage of 790 +/- 30 mV, and a fill factor of 0.72 +/- 0.03, corresponding to an overall conversion efficiency of 9.6% under standard AM (air mass) 1.5 sunlight, and demonstrated a stable performance under light and heat soaking at 80 degrees C.

  10. Estimation of the heat transfer coefficient in melt spinning process

    International Nuclear Information System (INIS)

    Tkatch, V I; Maksimov, V V; Grishin, A M

    2009-01-01

    Effect of the quenching wheel velocity in the range 20.7-26.5 m/s on the cooling rate as well as on the structure and microtopology of the contact surfaces of the glass-forming FeNiPB melt-spun ribbons has been experimentally studied. Both the values of the cooling rate and heat transfer coefficient at the wheel-ribbon interface estimated from the temperature vs. time curves recorded during melt spinning runs are in the ranges (1.6-5.2)x10 6 K/s and (2.8-5.2)x10 5 Wm -2 K -1 , respectively, for ribbon thicknesses of 31.4-22.0 μm. It was found that the density of the air pockets at the underside surface of ribbons decreases while its average depth remains essentially unchanged with the wheel velocity. Using the surface quality parameters the values of the heat transfer coefficient in the areas of direct ribbon-wheel contact were evaluated to be ranging from 5.75 to 6.65x10 5 Wm -2 K -1 .

  11. Density Modulation Experiments to Determine Particle Transport Coefficients on HT-7 Tokamak

    International Nuclear Information System (INIS)

    Jie Yinxian; Gao Xiang; Tanaka, K; Sakamoto, R; Toi, K; Liu Haiqing; Gao Li; Asif, M; Liu Jin; Xu Qiang; Tong Xingde; Cheng Yongfei

    2006-01-01

    The particle diffusion coefficient and the convection velocity were studied based on the density modulation using D 2 gas puffing on the HT-7 tokamak. The density was measured by a five-channel FIR interferometer. The density modulation amplitude was 10% of the central chord averaged background density and the modulation frequency was 10 Hz in the experiments. The particle diffusion coefficient (D) and the convection velocity (V) were obtained for different background plasmas with the central chord averaged density e > = 1.5x10 19 m -3 and 3.0x10 19 m -3 respectively. It was observed that the influence of density modulation on the main plasma parameters was very weak. This technology is expected to be useful for the analysis of LHW and IBW heated plasmas on HT-7 tokamak in the near future

  12. Current status on preparation of dose conversion factors based on 1990 ICRP recommendations

    International Nuclear Information System (INIS)

    Yoshizawa, Michio

    1996-01-01

    The current status of arrangement of dose conversion factors for operational quantities are explained on the basis of 1995 ICRP-ICRU recommendations. The dose conversion factors of photon, neutron and electron were recommended by ICRP Publ. 74. It's contents are described. The relation between new dose conversion factors and the laws in connection with protecting radiation are explained. The dose conversion factors of 1 cm-, 3 mm- and 70 μm - dose equivalent which were introduced into the laws connected therewith in Japan are accepted the same values of ICRP Publ. 51 for photon and neutron. I mentioned the points of discussing about new dose conversion factors which are expected to be recommended. The laws have to show the dose conversion factors to be used by calculation and estimation of radiation shield, etc. The limit of energy of ICRU individual dose equivalent for photon is now until 1 MeV, but the value is insufficient and necessary to 10 MeV as same as the ambient dose equivalent in due consideration of atomic energy facilities. JAERI is preparing these dose conversion factors now. (S.Y.)

  13. New-generation curing units and short irradiation time: the degree of conversion of microhybrid composite resin.

    Science.gov (United States)

    Scotti, Nicolla; Venturello, Alberto; Migliaretti, Giuseppe; Pera, Francesco; Pasqualini, Damiano; Geobaldo, Francesco; Berutti, Elio

    2011-09-01

    This in vitro study investigated the depth of cure of a microhybrid composite resin when cured with reduced times of exposure to three commercially available curing lights. Different sample thicknesses (1, 2, and 3 mm) were light cured in high intensity polymerization mode (2,400 mW/cm² for 5, 10, 15, and 20 seconds; 1,100 mW/cm² for 10, 20, 30, and 40 seconds; and 1,100 mW/cm² for 10, 20, 30, and 40 seconds, respectively). The degree of conversion (%) at the bottom of each sample was measured by Attenuated Total Reflection Fourier Transform Infrared (ATR F-TIR) analysis after each polymerization step. Data were analyzed by ANOVA for repeated measures, showing the degree of conversion was not influenced by the curing light employed (P = .622) but was significantly influenced by the thickness of composite resin (P conversion vs the shorter irradiation time permitted (T1) were not significant among different lamps but were significant among different thicknesses. The depth of cure of microhybrid composite resin appears not to be influenced by the curing light employed. Increased irradiation time significantly increases the degree of conversion. Thickness strongly influences depth of cure.

  14. Multimodal manifold-regularized transfer learning for MCI conversion prediction.

    Science.gov (United States)

    Cheng, Bo; Liu, Mingxia; Suk, Heung-Il; Shen, Dinggang; Zhang, Daoqiang

    2015-12-01

    As the early stage of Alzheimer's disease (AD), mild cognitive impairment (MCI) has high chance to convert to AD. Effective prediction of such conversion from MCI to AD is of great importance for early diagnosis of AD and also for evaluating AD risk pre-symptomatically. Unlike most previous methods that used only the samples from a target domain to train a classifier, in this paper, we propose a novel multimodal manifold-regularized transfer learning (M2TL) method that jointly utilizes samples from another domain (e.g., AD vs. normal controls (NC)) as well as unlabeled samples to boost the performance of the MCI conversion prediction. Specifically, the proposed M2TL method includes two key components. The first one is a kernel-based maximum mean discrepancy criterion, which helps eliminate the potential negative effect induced by the distributional difference between the auxiliary domain (i.e., AD and NC) and the target domain (i.e., MCI converters (MCI-C) and MCI non-converters (MCI-NC)). The second one is a semi-supervised multimodal manifold-regularized least squares classification method, where the target-domain samples, the auxiliary-domain samples, and the unlabeled samples can be jointly used for training our classifier. Furthermore, with the integration of a group sparsity constraint into our objective function, the proposed M2TL has a capability of selecting the informative samples to build a robust classifier. Experimental results on the Alzheimer's Disease Neuroimaging Initiative (ADNI) database validate the effectiveness of the proposed method by significantly improving the classification accuracy of 80.1 % for MCI conversion prediction, and also outperforming the state-of-the-art methods.

  15. Comparison of coal reactivity during conversion into different oxidizing medium

    International Nuclear Information System (INIS)

    Korotkikh, A G; Slyusarskiy, K V; Larionov, K B; Osipov, V I

    2016-01-01

    Acoal conversion process of different coal samples into three different types of oxidizing medium (argon, air and steam) were studied by means of thermogravimetry. Two coal types with different metamorphism degree (lignite and bituminous coal) were used. The experimental procedure was carried out in non-isothermal conditions in temperature range from 373 K to 1273 K with 20 K/min heating rate. Purge gas consisted of argon and oxidizer with volumetric ratio 1:24 and had 250 ml/min flow rate.The ignition and burnout indexes were calculated to evaluate sample reactivity at different oxidizing mediums. The highest reactivity coefficient values in same atmosphere were obtained for lignite. It was caused by higher particle special surface area and volatile matter content. (paper)

  16. Water Use and Crop Coefficients in Sprinkler Irrigated Rice

    Directory of Open Access Journals (Sweden)

    Antonino Spanu

    Full Text Available Field experiments were carried out during the years 2002, 2004, 2005 and 2006 to analyze water-soil-atmosphere interactions in sprinkler irrigated rice. The research was carried out in Sardinia (39º 59’ N; 8º 40’ E, at altitude 15 m. The cultivars used in the experiments, respectively in 2002 and in 2004-2005-2006, were Irat 212 and Eurosis. In each year cultivars were subjected to the same crop management. Irrigation was applied since the emergence with the sprinkler method, taking into account the loss of water from ‘Class A’ pan evaporation. Soil water content was monitored at 0.10 m intervals until 1.00-m depth using a ‘Diviner 2000’ (Sentek. In 2002 seven irrigation scheduling treatments were compared. In 2004, 2005, 2006 irrigation treatments provided for optimal soil water conditions during the growing season. In 2002 the results highlighted: 1 0-0.20 m depth was the most important layer for crop water uptake and the best correlated layer with rice rough yield; 2 the positive relationship between yield and water supply was significant until 6500 m3 ha-1 of water applied. Further seasonal irrigation volumes did not increase significantly yield. In 2004, 2005 and 2006 the analysis of the soil water balance at different crop phenological stages allowed to estimate crop coefficients (Kc using the Penman-Monteith equation and the ‘Class A’ pan evaporation (Kcev. Kc varied over the three-year period on average from 0.90 to 1.07 and 0.97, respectively for the emergence-end of tillering, end of tillering-heading and heading-maturing periods, while crop coefficients as a ratio between maximum crop evapotranspiration (ETc and Epan, Kcev ranged from 0.78 to 0.92 and 0.81 for the same time periods.

  17. Effect of Cooling Methods on Methane Conversion via Dielectric-Barrier Discharges

    International Nuclear Information System (INIS)

    Wang Baowei; Yang Kuanhui; Xu Genhui

    2008-01-01

    Effects of cooling methods on stability and methane conversion rate using dielectric-barrier discharges (DBD) were systematically investigated in this article. The results showed that the methane conversion rate was as high as 44.43% in a pure methane system at a flow rate of 100 mL ± min -1 and an input power of 234.2 W with air cooling. A dark greenish and soft film-like carbon was deposited on the outer surface of quartz tube when the outer electrode was water-cooled, which decreased the methane conversion. With air cooling of inner electrode the selectivity of C 2 hydrocarbons was higher than that with other cooling methods, while the C 3 hydrocarbons had higher selectivity with flowing water cooling. Cooling the inner electrode could restrain the carbon deposition, but would decrease the methane conversion rate. The stability of both reaction and plasma operation can be improved through cooling the reactor. From thermodynamic analysis, it was found that the effective collisions frequency among the reactant molecules and free electrons (e - ) increased with temperature, which in turn led to a higher methane conversion rate and a change in the distribution of products.

  18. The Biot coefficient for a low permeability heterogeneous limestone

    Science.gov (United States)

    Selvadurai, A. P. S.

    2018-04-01

    This paper presents the experimental and theoretical developments used to estimate the Biot coefficient for the heterogeneous Cobourg Limestone, which is characterized by its very low permeability. The coefficient forms an important component of the Biot poroelastic model that is used to examine coupled hydro-mechanical and thermo-hydro-mechanical processes in the fluid-saturated Cobourg Limestone. The constraints imposed by both the heterogeneous fabric and its extremely low intact permeability [K \\in (10^{-23},10^{-20}) m2 ] require the development of alternative approaches to estimate the Biot coefficient. Large specimen bench-scale triaxial tests (150 mm diameter and 300 mm long) that account for the scale of the heterogeneous fabric are complemented by results for the volume fraction-based mineralogical composition derived from XRD measurements. The compressibility of the solid phase is based on theoretical developments proposed in the mechanics of multi-phasic elastic materials. An appeal to the theory of multi-phasic elastic solids is the only feasible approach for examining the compressibility of the solid phase. The presence of a number of mineral species necessitates the use of the theories of Voigt, Reuss and Hill along with the theories proposed by Hashin and Shtrikman for developing bounds for the compressibility of the multi-phasic geologic material composing the skeletal fabric. The analytical estimates for the Biot coefficient for the Cobourg Limestone are compared with results for similar low permeability rocks reported in the literature.

  19. Widely tunable wavelength conversion with extinction ratio enhancement using PCF-based NOLM

    DEFF Research Database (Denmark)

    Kwok, C.H.; Lee, S.H.; Chow, K.K.

    2005-01-01

    A widely tunable wavelength conversion scheme has been demonstrated using a 64-m-long dispersion-flattened high-nonlinearity photonic crystal fiber in a nonlinear optical loop mirror. Wavelength conversion range of over 60 nm with a 10-Gb/s return-to-zero signal was obtained with the output...... extinction ratio (ER) maintained above 13 dB. The proposed scheme can also improve the output ER and remove the bit-error-rate floor if a degraded signal is used....

  20. [Correlation between the mRNA expression of tissue inhibitor of metalloproteinase-1 and apparent diffusion coefficient on diffusion-weighted imaging in rats' liver fibrosis].

    Science.gov (United States)

    Zhan, Yuefu; Liang, Xianwen; Han, Xiangjun; Chen, Jianqiang; Zhang, Shufang; Tan, Shun; Li, Qun; Wang, Xiong; Liu, Fan

    2017-02-28

    To explore the correlation between the apparent diffusion coefficient (ADC) and mRNA expression of tissue inhibitor of metalloproteinase-1 (TIMP-1) in different stages of liver fibrosis in rats.
 Methods: A model of liver fibrosis in rats was established by intraperitoneal injection of high-fat diet combined with porcine serum. After drug administration for 4 weeks, 48 rats served as a model group and 12 rats served as a control group, then they underwent diffusion weighted imaging (DWI) scanning. The value of ADC was calculated at b value=800 s/mm2. The rats were sacrificed and carried out pathologic examination after DWI scanning immediately. The mRNA expression of TIMP-1 was detected by real time-polymerase chain reaction (RT-PCR). The rats of hepatic fibrosis were also divided into a S0 group (n=4), a S1 group (n=11), a S2 group (n=12), a S3 group (n=10), and a S4 group (n=9) according to their pathological stage. The value of ADC and the expression of TIMP-1 mRNA among the different stage groups of liver fibrosis were compared, and the correlation between ADC and the TIMP-1 mRNA were analyzed.
 Results: The ADC value and the TIMP-1 mRNA expression were significantly different between the control group and the liver fibrosis group (F=46.54 and 53.87, P0.05). For the comparison of TIMP-1 mRNA, there was no significant difference between the S1 group and the S2 group, the S3 group and the S4 group (both P>0.05). There were significant differences among the rest of the groups (all Pcorrelation analysis showed that there was a negative correlation between the ADC value and the TIMP-1 mRNA expression (r=-0.76, Pcorrelation between them.