WorldWideScience

Sample records for lowest dose tested

  1. Search for the lowest irradiation dose from literatures on radiation-induced breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizawa, Y; Kusama, T [Tokyo Univ. (Japan). Faculty of Medicine

    1975-12-01

    A survey of past case reports concerning radiation-induced breast cancer was carried out in order to find the lowest irradiation dose. The search of literature published since 1951 revealed 10 cases of radiation-induced breast cancer. Only 5 cases had precise descriptions of the irradiation dose. The lowest irradiation dose was estimated at 1470 rads in the case of external X-ray irradiation for tuberous angioma. All of cases of radiation-induced breast cancer had received radiation for the treatment of nonmalignant tumors, such as pulmonary tuberculosis, mastitis, and tuberous angioma. There also were three statistical studies. The first concerned atomic bomb survivors, the second, pulmoanry tuberculous patients subjected to frequent fluoroscopies, and the third, patients of acute post partum mastitis. These statistical studies had revealed a significant increase in the incidence of breast cancer in the irradiated group, but there was little information about the lowest irradiation dose. It was noticed that radiation-induced breast cancer was more numerous in the upper inner quadrant of the breast. Most histopathological findings of radiation-induced breast cancer involved duct cell carcinoma. The latent period was about 15 years.

  2. Search for the lowest irradiation dose from literatures on radiation-induced cancer in uterus

    International Nuclear Information System (INIS)

    Yoshizawa, Yasuo; Kusama, Tomoko

    1975-01-01

    A survey of past case reports on radiation-induced cancer of the uterus was carried out with the main object of finding the lowest irradiation dose. Search of literature published since 1912 revealed 548 cases of radiation-induced cancer of the uterus. All of these cases of radiation-induced cancer had received radiation for the treatment of non-malignant disease. The primary gynecological conditions which were the object of radiation therapy were functional bleeding, endometrial hyperplasia, myoma, endometritis, and polyps. The lowest irradiation dose was estimated at 1000-1450 rad in the case of external X-ray irradiation, and 100 mg.hr for intrauterine radium therapy, which corresponds to 100-1000 rad. It was noted that were more cases of corpus cancer than cervical cancer. Histopathological findings of radiation-induced uterine cancer were carcinoma, sarcoma, and mixed mesodermal tumors. The latent period was distributed in the range of 1 to 40 years, with the average of 10.1 years. (auth.)

  3. Search for the lowest irradiation dose from literatures on radiation-induced bone tumor

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizawa, Y; Kusama, T; Morimoto, K [Tokyo Univ. (Japan). Faculty of Medicine

    1977-04-01

    A survey of past case reports of bone tumor induced by external radiation was carried out with the main object of finding the lowest irradiation dose. Search of the literature published since 1922 revealed 262 cases of radiation-induced bone tumor. These patients, except a patient with occupational exposure, had received radiation for treatment. The primary conditions as object of radiation therapy were nonmalignan bone diseases such as tuberclosis, giant cell tumor, fibrous dysplasia and bone cyst, and extra-skeletal diseases such as retinoblastoma, breast cancer and uterus cancer. The ratio of male to female patients with radiation-induced bone tumor was 1:1.3. The age of the patient ranged between 5 and 98 years, with an average of 37.6 years. Skeletal distribution of radiation-induced bone tumor was as follows: 20% the frontal and face bones, 17% the femur, 10% the humerus, 9% the vertebral column, and 44% other. The lowest absorbed dose reported was 800 rads in patients irradiated for the treatment of bone disease, but 1800 rads in patients with extra-skeletal disease. The latent period ranged between 2 and 42 years, with an average of 11.7 years. The histopathological findings were as follows: 60% osteosarcoma, 25% fibrosarcoma, 7% chondrosarcoma, and 8% other.

  4. Search for the lowest irradiation dose from literatures on radiation-induced cancer in gastrointestinal tract

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizawa, Y; Kusama, T [Tokyo Univ. (Japan). Faculty of Medicine

    1976-05-01

    A survey of past case reports about radiation-induced cancer in the gastrointestinal tract was carried out with the main object of finding the lowest irradiation dose. Search of the literature published since 1923 revealed 80 cases of radiation-induced large intestine cancer and one case of stomach cancer. The cases of radiation-induced cancer in the large intestine had received radiation for the treatment of non-malignant conditions, fibroma, ovarial cyste, myoma, endometritis and duodenal ulcer. The lowest irradiation dose was estimated at 460 rads. Adenocarcinoma was the histopathological finding in all cases of radiation-induced cancer in the caecum, colon and rectum, and squamous cell carcinoma in the cases of anal cancer. The latent period ranged from 1 to 31 years, with the average of 13.6 years. There were some reports of statistical studies of radiation-induced stomach cancer. Three groups were the subjects of these studies. The first group was composed of atomic bomb survivors, the second of patients who had undergone radiation treatment for ankylosing spondilitis, and the third of duodenal ulcer patients subjected to radiation treatment for the purpose of suppressing gastric acid secretion. These statistical studies showed no significant increase of the incidence of stomach cancer in the irradiated groups.

  5. Search for the lowest irradiation dose from literatures on radiation-induced cancer in gastrointestinal tract

    International Nuclear Information System (INIS)

    Yoshizawa, Yasuo; Kusama, Tomoko

    1976-01-01

    A survey of past case reports about radiation-induced cancer in the gastrointestinal tract was carried out with the main object of finding the lowest irradiation dose. Search of the literature published since 1923 revealed 80 cases of radiation-induced large intestine cancer and one case of stomach cancer. The cases of radiation-induced cancer in the large intestine had received radiation for the treatment of non-malignant conditions, fibroma, ovarial cyste, myoma, endometritis and duodenal ulcer. The lowest irradiation dose was estimated at 460 rads. Adenocarcinoma was the histopathological finding in all cases of radiation-induced cancer in the caecum, colon and rectum, and squamous cell carcinoma in the cases of anal cancer. The latent period ranged from 1 to 31 years, with the average of 13.6 years. There were some reports of statistical studies of radiation-induced stomach cancer. Three groups were the subjects of these studies. The first group was composed of atomic bomb survivors, the second of patients who had undergone radiation treatment for ankylosing spondilitis, and the third of duodenal ulcer patients subjected to radiation treatment for the purpose of suppressing gastric acid secretion. These statistical studies showed no significant increase of the incidence of stomach cancer in the irradiated groups. (auth.)

  6. Theoretical study of the lowest-lying electronic states of Aluminium monoiodide

    International Nuclear Information System (INIS)

    Taher, F.; Kabbani, A.; Ani-El Houte, W.

    2004-01-01

    Full text.The spectroscopic study of Aluminium monohalides, especially the Aluminium monoiodide, is important for monitoring such species in high temperature fast-flow reactors. Theoretical calculations of AlI are not available, whereas several studies have been done for the other aluminium monohalides. In this work, CAS-SCF/MRCI calculations are performed for the lowest-lying electronic states of AlI in a range of internuclear distance between 2.30 A and 2.80 A. Ab-initio calculations have been effectuated by using the computational chemistry program Molpro. The basis set used in this study for aluminium atom is that used by Langhoff for aluminium monohalides, of contractions using atomic natural orbitals and a pseudopotential is used for iode. Accurate theoretical spectroscopic constants and potential curves are obtained for the ground state X 1 Σ + and the first excited states a 3 Π and A 1 Π. The calculated values of Te, ωe, ωexe and re of these states are compatible with the experimental results. An ordering of states is represented for the lowest five predicted singlet and lowest five predicted triplet states. These results provide a big support to determine the analogy in the ordering of the electronic states in AlF, AlBr and AlI respectively at lower energies. These theoretical results identify a set of electronic singlet and triplet states unobserved experimentally

  7. Assessment of eight HPV vaccination programs implemented in lowest income countries

    Directory of Open Access Journals (Sweden)

    Ladner Joël

    2012-05-01

    Full Text Available Abstract Background Cervix cancer, preventable, continues to be the third most common cancer in women worldwide, especially in lowest income countries. Prophylactic HPV vaccination should help to reduce the morbidity and mortality associated with cervical cancer. The purpose of the study was to describe the results of and key concerns in eight HPV vaccination programs conducted in seven lowest income countries through the Gardasil Access Program (GAP. Methods The GAP provides free HPV vaccine to organizations and institutions in lowest income countries. The HPV vaccination programs were entirely developed, implemented and managed by local institutions. Institutions submitted application forms with institution characteristics, target population, communication delivery strategies. After completion of the vaccination campaign (3 doses, institutions provided a final project report with data on doses administered and vaccination models. Two indicators were calculated, the program vaccination coverage and adherence. Qualitative data were also collected in the following areas: government and community involvement; communication, and sensitization; training and logistics resources, and challenges. Results A total of eight programs were implemented in seven countries. The eight programs initially targeted a total of 87,580 girls, of which 76,983 received the full 3-dose vaccine course, with mean program vaccination coverage of 87.8%; the mean adherence between the first and third doses of vaccine was 90.9%. Three programs used school-based delivery models, 2 used health facility-based models, and 3 used mixed models that included schools and health facilities. Models that included school-based vaccination were most effective at reaching girls aged 9-13 years. Mixed models comprising school and health facility-based vaccination had better overall performance compared with models using just one of the methods. Increased rates of program coverage and

  8. Assessment of eight HPV vaccination programs implemented in lowest income countries.

    Science.gov (United States)

    Ladner, Joël; Besson, Marie-Hélène; Hampshire, Rachel; Tapert, Lisa; Chirenje, Mike; Saba, Joseph

    2012-05-23

    Cervix cancer, preventable, continues to be the third most common cancer in women worldwide, especially in lowest income countries. Prophylactic HPV vaccination should help to reduce the morbidity and mortality associated with cervical cancer. The purpose of the study was to describe the results of and key concerns in eight HPV vaccination programs conducted in seven lowest income countries through the Gardasil Access Program (GAP). The GAP provides free HPV vaccine to organizations and institutions in lowest income countries. The HPV vaccination programs were entirely developed, implemented and managed by local institutions. Institutions submitted application forms with institution characteristics, target population, communication delivery strategies. After completion of the vaccination campaign (3 doses), institutions provided a final project report with data on doses administered and vaccination models. Two indicators were calculated, the program vaccination coverage and adherence. Qualitative data were also collected in the following areas: government and community involvement; communication, and sensitization; training and logistics resources, and challenges. A total of eight programs were implemented in seven countries. The eight programs initially targeted a total of 87,580 girls, of which 76,983 received the full 3-dose vaccine course, with mean program vaccination coverage of 87.8%; the mean adherence between the first and third doses of vaccine was 90.9%. Three programs used school-based delivery models, 2 used health facility-based models, and 3 used mixed models that included schools and health facilities. Models that included school-based vaccination were most effective at reaching girls aged 9-13 years. Mixed models comprising school and health facility-based vaccination had better overall performance compared with models using just one of the methods. Increased rates of program coverage and adherence were positively correlated with the number of

  9. Population dose near the Semipalatinsk test site.

    Science.gov (United States)

    Hille, R; Hill, P; Bouisset, P; Calmet, D; Kluson, J; Seisebaev, A; Smagulov, S

    1998-10-01

    To determine the consequences of atmospheric atomic bomb tests for the population in the surroundings of the former nuclear weapons test site near Semipalatinsk in Kazakhstan, a pilot study was performed by an international cooperation between Kazakh, French, Czech and German institutions at two villages, Mostik and Maisk. Together with Kazakh scientists, eight experts from Europe carried out a field mission in September 1995 to assess, within the framework of a NATO supported project, the radiological situation as far as external doses, environmental contamination and body burden of man were concerned. A summary of the results obtained is presented. The actual radiological situation near the test site is characterized by fallout contaminations. Cs was found in upper soil layers in concentrations similar to those of the global fallout. Also Sr, Am and Co were observed. The resulting present dose to the population is low. Mean external doses from soil contamination for Maisk and Mostik (0.60-0.63 mSv/year) presently correspond to mean external doses in normal environments. Mean values of the annual internal doses observed in these two villages are below 2 microSv/year for 90Sr. For other radionuclides the internal doses are also negligible.

  10. Population dose near the Semipalatinsk test site

    International Nuclear Information System (INIS)

    Hille, R.; Hill, P.; Kluson, J.; Seisebaev, A.; Smagulov, S.

    1998-01-01

    To determine the consequences of atmospheric atomic bomb tests for the population in the surroundings of the former nuclear weapons test site near Semipalatinsk in Kazakhstan, a pilot study was performed by an international cooperation between Kazakh, French, Czech and German institutions at two villages, Mostik and Maisk. Together with Kazakh scientists, eight experts from Europe carried out a field mission in September 1995 to assess, within the framework of a NATO supported project, the radiological situation as far as external doses, environmental contamination and body burden of man were concerned. A summary of the results obtained is presented. The actual radiological situation near the test site is characterized by fallout contaminations. Cs was found in upper soil layers in concentrations similar to those of the global fallout. Also Sr, Am and Co were observed. The resulting present dose to the population is low. Mean external doses from soil contamination for Maisk and Mostik (0.60-0.63 mSv/ year) presently correspond to mean external doses in normal environments. Mean values of the annual internal doses observed in these two villages are below 2 μSv/year for 90 Sr. For other radionuclides the internal doses are also negligible. (orig.)

  11. Measured dose to ovaries and testes from Hodgkin's fields and determination of genetically significant dose

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.; Cumberlin, R.

    1993-01-01

    The purpose of this study was to determine the genetically significant dose from therapeutic radiation exposure with Hodgkin's fields by estimating the doses to ovaries and testes. Phantom measurements were performed to verify estimated doses to ovaries and testes from Hodgkin's fields. Thermoluminescent LiF dosimeters (TLD-100) of 1 x 3 x 3 mm 3 dimensions were embedded in phantoms and exposed to standard mantle and paraaortic fields using Co-60, 4 MV, 6 MV, and 10 MV photon beams. The results show that measured doses to ovaries and testes are about two to five times higher than the corresponding graphically estimated doses for Co-60 and 4 MVX photon beams as depicted in ICRP publication 44. In addition, the measured doses to ovaries and testes are about 30% to 65% lower for 10 MV photon beams than for their corresponding Co-60 photon beams. The genetically significant dose from Hodgkin's treatment (less than 0.01 mSv) adds about 4% to the genetically significant dose contribution to medical procedures and adds less than 1% to the genetically significant dose from all sources. Therefore, the consequence to society is considered to be very small. The consequences for the individual patient are, likewise, small. 28 refs., 3 figs., 5 tabs

  12. Testing ΛCDM at the lowest redshifts with SN Ia and galaxy velocities

    Energy Technology Data Exchange (ETDEWEB)

    Huterer, Dragan; Shafer, Daniel L. [Department of Physics, University of Michigan, 450 Church Street, Ann Arbor, MI 48109 (United States); Scolnic, Daniel M. [University of Chicago, Kavli Institute for Cosmological Physics, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Schmidt, Fabian, E-mail: huterer@umich.edu, E-mail: dshafer2@jhu.edu, E-mail: dscolnic@kicp.uchicago.edu, E-mail: fabians@mpa-garching.mpg.de [Max-Planck-Institut für Astrophysik, Karl-Schwarzschild-Str. 1, 85748 Garching (Germany)

    2017-05-01

    Peculiar velocities of objects in the nearby universe are correlated due to the gravitational pull of large-scale structure. By measuring these velocities, we have a unique opportunity to test the cosmological model at the lowest redshifts. We perform this test, using current data to constrain the amplitude of the ''signal'' covariance matrix describing the velocities and their correlations. We consider a new, well-calibrated ''Supercal'' set of low-redshift SNe Ia as well as a set of distances derived from the fundamental plane relation of 6dFGS galaxies. Analyzing the SN and galaxy data separately, both results are consistent with the peculiar velocity signal of our fiducial ΛCDM model, ruling out the noise-only model with zero peculiar velocities at greater than 7σ (SNe) and 8σ (galaxies). When the two data sets are combined appropriately, the precision of the test increases slightly, resulting in a constraint on the signal amplitude of A = 1.05{sub −0.21}{sup +0.25}, where A = 1 corresponds to our fiducial model. Equivalently, we report an 11% measurement of the product of the growth rate and amplitude of mass fluctuations evaluated at z {sub eff} = 0.02, f σ{sub 8} = 0.428{sub −0.045}{sup +0.048}, valid for our fiducial ΛCDM model. We explore the robustness of the results to a number of conceivable variations in the analysis and find that individual variations shift the preferred signal amplitude by less than ∼0.5σ. We briefly discuss our Supercal SN Ia results in comparison with our previous results using the JLA compilation.

  13. Ingestion of Nevada Test Site Fallout: Internal dose estimates

    International Nuclear Information System (INIS)

    Whicker, F.W.; Kirchner, T.B.; Anspaugh, L.R.

    1996-01-01

    This paper summarizes individual and collective dose estimates for the internal organs of hypothetical yet representative residents of selected communities that received measurable fallout from nuclear detonations at the Nevada Test Site. The doses, which resulted from ingestion of local and regional food products contaminated with over 20 radionuclides, were estimated with use of the PATHWAY food-chain-transport model to provide estimates of central tendency and uncertainty. The thyroid gland received much higher doses than other internal organs and tissues. In a avery few cases, infants might have received thyroid doses in excess of 1 Gy, depending on location, diet, and timing of fallout. 131 I was the primary thyroid dose contributor, and fresh milk was the main exposure pathway. With the exception of the thyroid, organ doses from the ingestion pathway were much smaller (<3%) than those from external gamma exposure to deposited fallout. Doses to residents living closest to the Nevada Test Site were contributed mainly by a few fallout events; doses to more distantly located people were generally smaller, but a greater number of events provided measurable contributions. The effectiveness of different fallout events in producing internal organ doses through ingestion varied dramatically with seasonal timing of the test, with maximum dose per unit fallout occurring for early summer depositions when milk cows were on pasture and fresh, local vegetables were used. Within specific communities, internal doses differed by age, sex, and lifestyle. Collective internal dose estimates for specific geographic areas are provided

  14. Electromagnetic structure of the lowest-lying decuplet resonances in covariant chiral perturbation theory

    International Nuclear Information System (INIS)

    Geng, L. S.; Camalich, J. Martin; Vacas, M. J. Vicente

    2009-01-01

    We present a calculation of the leading SU(3)-breaking O(p 3 ) corrections to the electromagnetic moments and charge radius of the lowest-lying decuplet resonances in covariant chiral perturbation theory. In particular, the magnetic dipole moment of the members of the decuplet is predicted fixing the only low-energy constant (LEC) present up to this order with the well-measured magnetic dipole moment of the Ω - . We predict μ Δ ++ =6.04(13) and μ Δ + =2.84(2), which agree well with the current experimental information. For the electric quadrupole moment and the charge radius, we use state-of-the-art lattice QCD results to determine the corresponding LECs, whereas for the magnetic octupole moment there is no unknown LEC up to the order considered here, and we obtain a pure prediction. We compare our results with those reported in large N c , lattice QCD, heavy-baryon chiral perturbation theory, and other models.

  15. Standard Test Method for Measuring Dose for Use in Linear Accelerator Pulsed Radiation Effects Tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers a calorimetric measurement of the total dose delivered in a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode) used as an ionizing source in radiation-effects testing. The test method is designed for use with pulses of electrons in the energy range from 10 to 50 MeV and is only valid for cases in which both the calorimeter and the test specimen to be irradiated are“thin” compared to the range of these electrons in the materials of which they are constructed. 1.2 The procedure described can be used in those cases in which (1) the dose delivered in a single pulse is 5 Gy (matl) (500 rd (matl)) or greater, or (2) multiple pulses of a lower dose can be delivered in a short time compared to the thermal time constant of the calorimeter. Matl refers to the material of the calorimeter. The minimum dose per pulse that can be acceptably monitored depends on the variables of the particular test, including pulse rate, pulse uniformity...

  16. Health effects of daily airborne particle dose in children: Direct association between personal dose and respiratory health effects

    International Nuclear Information System (INIS)

    Buonanno, Giorgio; Marks, Guy B.; Morawska, Lidia

    2013-01-01

    Air pollution is a widespread health problem associated with respiratory symptoms. Continuous exposure monitoring was performed to estimate alveolar and tracheobronchial dose, measured as deposited surface area, for 103 children and to evaluate the long-term effects of exposure to airborne particles through spirometry, skin prick tests and measurement of exhaled nitric oxide (eNO). The mean daily alveolar deposited surface area dose received by children was 1.35 × 10 3 mm 2 . The lowest and highest particle number concentrations were found during sleeping and eating time. A significant negative association was found between changes in pulmonary function tests and individual dose estimates. Significant differences were found for asthmatics, children with allergic rhinitis and sensitive to allergens compared to healthy subjects for eNO. Variation is a child's activity over time appeared to have a strong impact on respiratory outcomes, which indicates that personal monitoring is vital for assessing the expected health effects of exposure to particles. -- Highlights: •Particle dose was estimated through personal monitoring on more than 100 children. •We focused on real-time daily dose of particle alveolar deposited surface area. •Spirometry, skin prick and exhaled Nitric Oxide tests were performed. •Negative link was found between changes in pulmonary functions and individual doses. •A child's lifestyle appeared to have a strong impact on health respiratory outcomes. -- The respiratory health effects of daily airborne particle dose on children through personal monitoring

  17. Global dose to man from proposed NNTRP high altitude nuclear tests

    International Nuclear Information System (INIS)

    Peterson, K.R.

    1975-05-01

    Radionuclide measurements from past high altitude nuclear testing have enabled development of a model to estimate surface deposition and doses from 400 kt of fission products injected in winter within the Pacific Test Area at altitudes in excess of 50 km. The largest 30-year average dose to man is about 10 millirem and occurs at 30 0 to 50 0 N latitude. The principal contributor to this dose is external gamma radiation from gross fission products. Individual doses from 90 Sr via the forage-cow-milk pathway and 137 Cs via the pasture-meat pathway are about 1/5 the gross fission product doses. The global 30-year population dose is 3 x 10 7 person-rem, which compares with a 30-year natural background population dose of 1 X 10 10 person-rem. Due in large part to the global distribution of population, over 98 percent of the global person-rem from the proposed high altitude tests is received in the Northern Hemisphere, while about 75 percent of the total population dose occurs within the 30 0 --50 0 N latitude belt. Detonations in summer would decrease the global dose by about a factor of three. (U.S.)

  18. Take with Food: Study Tests Lowering Dose of Prostate Cancer Drug

    Science.gov (United States)

    ... Cancer Currents Blog Cancer Currents Blog Take with Food: Study Tests Lowering Dose of Prostate Cancer Drug Subscribe April ... to this page included, e.g., “Take with Food: Study Tests Lowering Dose of Prostate Cancer Drug was originally ...

  19. Evaluation of accelerated test parameters for CMOS IC total dose hardness prediction

    International Nuclear Information System (INIS)

    Sogoyan, A.V.; Nikiforov, A.Y.; Chumakov, A.I.

    1999-01-01

    The approach to accelerated test parameters evaluation is presented in order to predict CMOS IC total dose behavior in variable dose-rate environment. The technique is based on the analytical model of MOSFET parameters total dose degradation. The simple way to estimate model parameter is proposed using IC's input-output MOSFET radiation test results. (authors)

  20. West Nile virus infection in American Robins: new insights on dose response.

    Directory of Open Access Journals (Sweden)

    Kaci K VanDalen

    Full Text Available West Nile virus (WNV is a vector-borne pathogen that was first detected in the United States in 1999. The natural transmission cycle of WNV involves mosquito vectors and avian hosts, which vary in their competency to transmit the virus. American robins are an abundant backyard species in the United States and appear to have an important role in the amplification and dissemination of WNV. In this study we examine the response of American robins to infection with various WNV doses within the range of those administered by some natural mosquito vectors. Thirty American robins were assigned a WNV dosage treatment and needle inoculated with 10(0.95 PFU, 10(1.26 PFU, 10(2.15 PFU, or 10(3.15 PFU. Serum samples were tested for the presence of infectious WNV and/or antibodies, while oral swabs were tested for the presence of WNV RNA. Five of the 30 (17% robins had neutralizing antibodies to WNV prior to the experiment and none developed viremia or shed WNV RNA. The proportion of WNV-seronegative birds that became viremic after WNV inoculation increased in a dose dependent manner. At the lowest dose, only 40% (2/5 of the inoculated birds developed productive infections while at the highest dose, 100% (7/7 of the birds became viremic. Oral shedding of WNV RNA followed a similar trend where robins inoculated with the lower two doses were less likely to shed viral RNA (25% than robins inoculated with one of the higher doses (92%. Viremia titers and morbidity did not increase in a dose dependent manner; only two birds succumbed to infection and, interestingly, both were inoculated with the lowest dose of WNV. It is clear that the disease ecology of WNV is a complex interplay of hosts, vectors, and viral dose delivered.

  1. A step-up test procedure to find the minimum effective dose.

    Science.gov (United States)

    Wang, Weizhen; Peng, Jianan

    2015-01-01

    It is of great interest to find the minimum effective dose (MED) in dose-response studies. A sequence of decreasing null hypotheses to find the MED is formulated under the assumption of nondecreasing dose response means. A step-up multiple test procedure that controls the familywise error rate (FWER) is constructed based on the maximum likelihood estimators for the monotone normal means. When the MED is equal to one, the proposed test is uniformly more powerful than Hsu and Berger's test (1999). Also, a simulation study shows a substantial power improvement for the proposed test over four competitors. Three R-codes are provided in Supplemental Materials for this article. Go to the publishers online edition of Journal of Biopharmaceutical Statistics to view the files.

  2. The lowest-dose, extended-cycle combined oral contraceptive pill with continuous ethinyl estradiol in the United States: a review of the literature on ethinyl estradiol 20 µg/levonorgestrel 100 µg + ethinyl estradiol 10 µg

    Directory of Open Access Journals (Sweden)

    Sheila Krishnan

    2010-08-01

    Full Text Available Sheila Krishnan, Jessica KileyDepartment of Obstetrics and Gynecology, Northwestern University, Chicago, Illinois, USAAbstract: Extended-cycle oral contraceptives (OCs are increasing in popularity in the United States. A new extended-cycle OC that contains the lowest doses of ethinyl estradiol (EE and levonorgestrel (LNG + continuous EE throughout the cycle is now available. It provides 84 days of a low-dose, combined active pill containing levonorgestrel 100 µg and ethinyl estradiol 20 µg. Instead of 7 days of placebo following the active pills, the regimen delivers 7 days of ethinyl estradiol 10 µg. Existing studies reveal a similar efficacy and adverse effect profile compared with other extended-regimen OCs. Specifically, the unscheduled bleeding profile is similar to other extended-cycle OCs and improves with the increase in the duration of use. Although lower daily doses of hormonal exposure have potential benefit, to our knowledge, there are no published studies indicating that this specific regimen offers a lower incidence of hormone-related side effects or adverse events. In summary, this new extended-cycle OC provides patients a low-dose, extended-regimen OC option without sacrificing efficacy or tolerability.Keywords: continuous regimen, ethinyl estradiol, extended cycle, oral contraceptive

  3. Non-linear dose-response of aluminium hydroxide adjuvant particles: Selective low dose neurotoxicity

    International Nuclear Information System (INIS)

    Crépeaux, Guillemette; Eidi, Housam; David, Marie-Odile; Baba-Amer, Yasmine; Tzavara, Eleni; Giros, Bruno; Authier, François-Jérôme; Exley, Christopher; Shaw, Christopher A.; Cadusseau, Josette

    2017-01-01

    Aluminium (Al) oxyhydroxide (Alhydrogel ® ), the main adjuvant licensed for human and animal vaccines, consists of primary nanoparticles that spontaneously agglomerate. Concerns about its safety emerged following recognition of its unexpectedly long-lasting biopersistence within immune cells in some individuals, and reports of chronic fatigue syndrome, cognitive dysfunction, myalgia, dysautonomia and autoimmune/inflammatory features temporally linked to multiple Al-containing vaccine administrations. Mouse experiments have documented its capture and slow transportation by monocyte-lineage cells from the injected muscle to lymphoid organs and eventually the brain. The present study aimed at evaluating mouse brain function and Al concentration 180 days after injection of various doses of Alhydrogel ® (200, 400 and 800 μg Al/kg of body weight) in the tibialis anterior muscle in adult female CD1 mice. Cognitive and motor performances were assessed by 8 validated tests, microglial activation by Iba-1 immunohistochemistry, and Al level by graphite furnace atomic absorption spectroscopy. An unusual neuro-toxicological pattern limited to a low dose of Alhydrogel ® was observed. Neurobehavioural changes, including decreased activity levels and altered anxiety-like behaviour, were observed compared to controls in animals exposed to 200 μg Al/kg but not at 400 and 800 μg Al/kg. Consistently, microglial number appeared increased in the ventral forebrain of the 200 μg Al/kg group. Cerebral Al levels were selectively increased in animals exposed to the lowest dose, while muscle granulomas had almost Completely disappeared at 6 months in these animals. We conclude that Alhydrogel ® injected at low dose in mouse muscle may selectively induce long-term Al cerebral accumulation and neurotoxic effects. To explain this unexpected result, an avenue that could be explored in the future relates to the adjuvant size since the injected suspensions corresponding to the lowest dose

  4. Low-dose dental CT

    International Nuclear Information System (INIS)

    Rustemeyer, P.; Eich, H.T.; John-Mikolajewski, V.; Mueller, R.D.

    1999-01-01

    Purpose: The intention of this study was to reduce patient dose during dental CT in the planning for osseointegrated implants. Methods and Materials: Dental CTs were performed with a spiral CT (Somatom Plus 4, Siemens) and a dental software package. Use of the usual dental CT technique (120 kVp; 165 mA, 1 s rotation time, 165 mAs; pitch factor 1) was compared with a new protocol (120 kVp; 50 mA; 0.7 s rotation time; 35 mAs; pitch factor 2) which delivered the best image quality at the lowest possible radiation dose, as tested in a preceding study. Image quality was analysed using a human anatomic head preparation. Four radiologists analysed the images independently. A Wilcoxon rank pair-test was used for statistic evaluation. The doses to the thyroid gland, the active bone marrow, the salivary glands, and the eye lens were determined in a tissue-equivalent phantom (Alderson-Rando Phantom) with lithium fluoride thermoluminescent dosimeters at the appropriate locations. Results: By mAs reduction from 165 to 35 and using a pitch factor of 2, the radiation dose could be reduced by a factor of nine (max.) (e.g., the bone marrow dose could be reduced from 23.6 mSv to 2.9 mSv, eye lens from 0.5 mSv to 0.3 mSv, thyroid gland from 2.5 mSv to 0.5 mSv, parotid glands from 2.3 mSv to 0.4 mSv). The dose reduction did not lead to an actual loss of image quality or diagnostic information. Conclusion: A considerable dose reduction without loss of diagnostic information is achievable in dental CT. Dosereducing examination protocols like the one presented may further expand the use of preoperative dental CT. (orig.) [de

  5. External doses of residents near semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Takada, Jun; Hoshi, Masaharu; Nagatomo, Tsuneto

    1999-01-01

    Accumulated external radiation doses of residents near the Semipalatinsk nuclear test site of the former USSR are presented as a results of study by the thermoluminescence technique for bricks sampled at several settlements in 1995 and 1996. The external doses that we evaluated from exposed bricks were up to about 100 cGy for resident. The external doses at several points in the center of Semipalatinsk City ranged from a background level to 60 cGy, which was remarkably high compared with the previously reported values based on military data. (author)

  6. Testing of the analytical anisotropic algorithm for photon dose calculation

    International Nuclear Information System (INIS)

    Esch, Ann van; Tillikainen, Laura; Pyykkonen, Jukka; Tenhunen, Mikko; Helminen, Hannu; Siljamaeki, Sami; Alakuijala, Jyrki; Paiusco, Marta; Iori, Mauro; Huyskens, Dominique P.

    2006-01-01

    The analytical anisotropic algorithm (AAA) was implemented in the Eclipse (Varian Medical Systems) treatment planning system to replace the single pencil beam (SPB) algorithm for the calculation of dose distributions for photon beams. AAA was developed to improve the dose calculation accuracy, especially in heterogeneous media. The total dose deposition is calculated as the superposition of the dose deposited by two photon sources (primary and secondary) and by an electron contamination source. The photon dose is calculated as a three-dimensional convolution of Monte-Carlo precalculated scatter kernels, scaled according to the electron density matrix. For the configuration of AAA, an optimization algorithm determines the parameters characterizing the multiple source model by optimizing the agreement between the calculated and measured depth dose curves and profiles for the basic beam data. We have combined the acceptance tests obtained in three different departments for 6, 15, and 18 MV photon beams. The accuracy of AAA was tested for different field sizes (symmetric and asymmetric) for open fields, wedged fields, and static and dynamic multileaf collimation fields. Depth dose behavior at different source-to-phantom distances was investigated. Measurements were performed on homogeneous, water equivalent phantoms, on simple phantoms containing cork inhomogeneities, and on the thorax of an anthropomorphic phantom. Comparisons were made among measurements, AAA, and SPB calculations. The optimization procedure for the configuration of the algorithm was successful in reproducing the basic beam data with an overall accuracy of 3%, 1 mm in the build-up region, and 1%, 1 mm elsewhere. Testing of the algorithm in more clinical setups showed comparable results for depth dose curves, profiles, and monitor units of symmetric open and wedged beams below d max . The electron contamination model was found to be suboptimal to model the dose around d max , especially for physical

  7. Dose Prediction for surface nuclear explosions: case studies for Semipalatinsk and Lop Nur tests

    International Nuclear Information System (INIS)

    Takada, Jun

    2008-01-01

    Dose prediction method RAPS after surface nuclear explosion has been developed by using the empirical dose function of USA nuclear test. This method which provides us external total dose, dose rate at any distant, at any time for any yield of nuclear explosion, is useful for radiation protection in case of nuclear events such as terrorism and nuclear war. The validity of RAPS has been confirmed by application to historical surface nuclear test explosions. The first test case study which was done for the first test explosion of the former USSR at the Semipalatinsk Nuclear Test Site on August 29th 1949, shows a good agreement with luminescence dosimetry on a brick. This dose prediction method was applied nuclear tests in Lop Nur. The results indicate dangerous nuclear radiation influences including fatal risk in the wide Uygur area. (author)

  8. The guinea pig maximization test--with a multiple dose design

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Vølund, A; Frankild, S

    1995-01-01

    The guinea pig maximization test (GPMT) is usually performed with one moderately irritant induction dose of the allergen and gives a qualitative assessment-hazard identification-of the allergenicity of the chemical. We refined the GPMT by applying a multiple dose design and used 30 guinea pigs in...

  9. The guinea pig maximization test--with a multiple dose design

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Vølund, A; Frankild, S

    1995-01-01

    The guinea pig maximization test (GPMT) is usually performed with one moderately irritant induction dose of the allergen and gives a qualitative assessment-hazard identification-of the allergenicity of the chemical. We refined the GPMT by applying a multiple dose design and used 30 guinea pigs...

  10. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  11. Spatial interpolation of gamma dose in radioactive waste storage facility

    Science.gov (United States)

    Harun, Nazran; Fathi Sujan, Muhammad; Zaidi Ibrahim, Mohd

    2018-01-01

    External radiation measurement for a radioactive waste storage facility in Malaysian Nuclear Agency is a part of Class G License requirement under Atomic Licensing Energy Board (AELB). The objectives of this paper are to obtain the distribution of radiation dose, create dose database and generate dose map in the storage facility. The radiation dose measurement is important to fulfil the radiation protection requirement to ensure the safety of the workers. There are 118 sampling points that had been recorded in the storage facility. The highest and lowest reading for external radiation recorded is 651 microSv/hr and 0.648 microSv/hour respectively. The calculated annual dose shows the highest and lowest reading is 1302 mSv/year and 1.3 mSv/year while the highest and lowest effective dose reading is 260.4 mSv/year and 0.26 mSv/year. The result shows that the ALARA concept along time, distance and shield principles shall be adopted to ensure the dose for the workers is kept below the dose limit regulated by AELB which is 20 mSv/year for radiation workers. This study is important for the improvement of planning and the development of shielding design for the facility.

  12. Dose reduction for snubber inspection and testing

    International Nuclear Information System (INIS)

    Morrison, G.M.; Cotton, S.R.

    1991-01-01

    This paper reports that Health physics staff members at Grand Gulf Nuclear Station have implemented several dose reduction methods for snubber inspection, testing and changeout. These methods include construction maps to permit easy location of snubbers in the drywell, painting azimuth numbers on the inside drywell wall and biological shield wall to coincide with the maps, requiring pre-job briefings for quality inspectors and craft support personnel, using job history files for work planning, using experienced inspectors and craft personnel whenever possible, designating certain craft personnel solely for snubber work, and cutting out stuck snubber pins rather than attempting intact removal. The total dose for snubber-related tasks has been significantly reduced using these methods

  13. Mixing of the lowest-lying qqq configurations with JP =1/2- in different hyperfine interaction models

    Science.gov (United States)

    Chen, Jia; An, Chunsheng; Chen, Hong

    2018-02-01

    We investigate mixing of the lowest-lying qqq configurations with JP = 1/2- caused by the hyperfine interactions between quarks mediated by Goldstone Boson Exchange, One Gluon Exchange, and both Goldstone Boson and One Gluon exchange, respectively. The first orbitally excited nucleon, Σ, Λ and Ξ states are considered. Contributions of both the contact term and tensor term are taken into account. Our numerical results show that mixing of the studied configurations in the two employed hyperfine interaction models are very different. Therefore, the present results, which should affect the strong and electromagnetic decays of baryon resonances, may be used to examine the present employed hyperfine interaction models. Supported by National Natural Science Foundation of China (11675131,11645002), Chongqing Natural Science Foundation (cstc2015jcyjA00032) and Fundamental Research Funds for the Central Universities (SWU115020)

  14. An improved standard total dose test for CMOS space electronics

    International Nuclear Information System (INIS)

    Fleetwood, D.M.; Winokur, P.S.; Riewe, L.C.; Pease, R.L.

    1989-01-01

    The postirradiation response of hardened and commercial CMOS devices is investigated as a function of total dose, dose rate, and annealing time and temperature. Cobalt-60 irradiation at ≅ 200 rad(SiO 2 )/s followed by a 1-week 100 degrees C biased anneal and testing is shown to be an effective screen of hardened devices for space use. However, a similar screen and single-point test performed after Co-60 irradiation and elevated temperature anneal cannot be generally defined for commercial devices. In the absence of detailed knowledge about device and circuit radiation response, a two-point standard test is proposed to ensure space surviability of CMOS circuits: a Co-60 irradiation and test to screen against oxide-trapped charge related failures, and an additional rebound test to screen against interface-trap related failures. Testing implications for bipolar technologies are also discussed

  15. Immediate hypersensitivity to iodinated contrast media: diagnostic accuracy of skin tests and intravenous provocation test with low dose.

    Science.gov (United States)

    Sesé, L; Gaouar, H; Autegarden, J-E; Alari, A; Amsler, E; Vial-Dupuy, A; Pecquet, C; Francès, C; Soria, A

    2016-03-01

    The diagnosis of HSR to iodinated contrast media (ICM) is challenging based on clinical history and skin tests. This study evaluates the negative predictive value (NPV) of skin tests and intravenous provocation test (IPT) with low-dose ICM in patients with suspected immediate hypersensitivity reaction (HSR) to ICM. Thirty-seven patients with suspected immediate hypersensitivity reaction to ICM were included retrospectively. Skin tests and a single-blind placebo-controlled intravenous provocation test (IPT) with low-dose iodinated contrast media (ICM) were performed. Skin tests with ICM were positive in five cases (one skin prick test and five intradermal test). Thirty-six patients were challenged successfully by IPT, and only one patient had a positive challenge result, with a grade I reaction by the Ring and Messmer classification. Ten of 23 patients followed up by telephone were re-exposed to a negative tested ICM during radiologic examination; two experienced a grade I immediate reaction. For immediate hypersensitivity reaction to ICM, the NPV for skin tests and IPT with low dose was 80% (95% CI 44-97%). © 2016 John Wiley & Sons Ltd.

  16. Dose assessment, radioecology, and community interaction at former nuclear test sites

    International Nuclear Information System (INIS)

    Robison, W.L.

    1994-11-01

    The US conducted a nuclear testing program at Bikini and Enewetak Atolls in the Marshall Islands from 1946 through 1958. A total of 66 nuclear devices were tested--23 at Bikini Atoll (total yield of 77 megatons) and 43 at Enewetak Atoll (total yield of 33 megatons). This resulted in contamination of many of the islands at each atoll. The BRAVO test (yield 15 megatons) on March 1, 1954 contaminated several atolls to the east of Bikini Atoll some of which were inhabited. The author has conducted an experimental, monitoring, and dose assessment program at atolls in the northern Marshall Islands for the past 20 years. The goals have been to: (1) determine the radiological conditions at the atolls; (2) provide dose assessments for resettlement options and alternate living patterns; (3) develop and evaluate remedial measures to reduce the dose to people reinhabiting the atolls; and (4) discuss the results with each of the communities and the Republic of the Marshall Islands government officials to help them understand the data as a basis for resettlement decisions. The remaining radionuclides at the atolls that contribute any significant dose are 137 Cs, 90 Sr, 239+240 Pu, and 241 Am

  17. Correlation between induced embryo toxicity and absorption dose of enriched uranium in testes

    International Nuclear Information System (INIS)

    Zhu Shoupeng; Lun Mingyue

    1996-01-01

    Doses of enriched uranium in testes inducing dominant lethality and skeletal abnormalities in offsprings are estimated. When intra-testicular injection dose is 0.4∼60 μg enriched uranium; from intake to insemination, testes could receive 9.14 x 10 -5 ∼1.38 x 10 -2 Gy radiation dose. Experimental results show that with the increase in the absorption dose, the number of living fetuses in a litter decreases, dominant lethality and skeletal abnormalities rise. It should be noted that relationship between the injected dose (I in μg) and the incidence of dominant skeletal abnormalities (S in %) in the offsprings can be represented by equation: S = 28.84 + 0.84I

  18. Correlation between induced embryo toxicity and absorption dose of enriched uranium in testes

    Energy Technology Data Exchange (ETDEWEB)

    Shoupeng, Zhu; Mingyue, Lun [Suzhou Medical Coll., JS (China)

    1996-08-01

    Doses of enriched uranium in testes inducing dominant lethality and skeletal abnormalities in offsprings are estimated. When intra-testicular injection dose is 0.4{approx}60 {mu}g enriched uranium; from intake to insemination, testes could receive 9.14 x 10{sup -5}{approx}1.38 x 10{sup -2} Gy radiation dose. Experimental results show that with the increase in the absorption dose, the number of living fetuses in a litter decreases, dominant lethality and skeletal abnormalities rise. It should be noted that relationship between the injected dose (I in {mu}g) and the incidence of dominant skeletal abnormalities (S in %) in the offsprings can be represented by equation: S = 28.84 + 0.84I.

  19. Effect on moisture permeability of typewriting on unit dose package surfaces.

    Science.gov (United States)

    Rackson, J T; Zellhofer, M J; Birmingham, P H

    1984-10-01

    The effects of typewriting on labels of two unit dose packages with respect to moisture permeability were examined. Using an electric typewriter, a standard label format was imprinted on two different types of class A unit dose packages: (1) a heat-sealed paper-backed foil and cellofilm strip pouch, and (2) a copolyester and polyethylene multiple-cup blister with a heat-sealed paper-backed foil and cellofilm cover. The labels were typed at various typing-element impact settings. The official USP test for water permeation was then performed on typed packages and untyped control packages. The original untyped packages were confirmed to be USP class A quality. The packages for which successively harder impact settings were used showed a corresponding increase in moisture permeability. This resulted in a lowering of USP package ratings from class A to class B and D, some of which would be unsuitable for use in any unit dose system under current FDA repackaging standards. Typing directly onto the label of a unit dose package before it is sealed will most likely damage the package and possibly make it unfit for use. Pharmacists who must type labels for the unit dose packages studied should use the lowest possible typewriter impact setting and test for damage using the USP moisture-permeation test.

  20. Enhanced low dose rate radiation effect test on typical bipolar devices

    International Nuclear Information System (INIS)

    Liu Minbo; Chen Wei; Yao Zhibin; He Baoping; Huang Shaoyan; Sheng Jiangkun; Xiao Zhigang; Wang Zujun

    2014-01-01

    Two types of bipolar transistors and nine types bipolar integrated circuit were selected in the irradiation experiment at different "6"0Co γ dose rate. The base current of bipolar transistor and input bias current of amplifier and comparator was measured, low dose enhance factor of test device was obtained. The results show that bipolar device have enhanced low dose rate sensitivity, enhancement factor of bipolar integrated circuit was bigger than that of transistor, and enhanced low dose rate sensitivity greatly varied with different structure and process of bipolar device. (authors)

  1. Giant angular resonance and the structure of the lowest-lying nuclear states

    International Nuclear Information System (INIS)

    Mikhajlov, I.N.; Usmanov, P.N.; Yuldashbaeva, Eh.Kh.

    1987-01-01

    The analysis is given of the Hamiltonian of the two-rotor model, which is based on the assumption that the giant angular resonance exists, i.e. that it is possible to rotate the neutron component of a deformed nucleus as a whole with respect to the proton component. The realization of the projections on the intrinsic axes of the angular momentum operators is found, the Hamiltonian matrix is determined in the basis convenient for the case of strong neutron-proton coupling. The spectrum of the two-rotor model is determined taking into account the nondiagonal matrix elements in the lowest order of the perturbation theory. The g factors and the probabilities of the M1 transitions are discussed

  2. Lowest order Virtual Element approximation of magnetostatic problems

    Science.gov (United States)

    Beirão da Veiga, L.; Brezzi, F.; Dassi, F.; Marini, L. D.; Russo, A.

    2018-04-01

    We give here a simplified presentation of the lowest order Serendipity Virtual Element method, and show its use for the numerical solution of linear magneto-static problems in three dimensions. The method can be applied to very general decompositions of the computational domain (as is natural for Virtual Element Methods) and uses as unknowns the (constant) tangential component of the magnetic field $\\mathbf{H}$ on each edge, and the vertex values of the Lagrange multiplier $p$ (used to enforce the solenoidality of the magnetic induction $\\mathbf{B}=\\mu\\mathbf{H}$). In this respect the method can be seen as the natural generalization of the lowest order Edge Finite Element Method (the so-called "first kind N\\'ed\\'elec" elements) to polyhedra of almost arbitrary shape, and as we show on some numerical examples it exhibits very good accuracy (for being a lowest order element) and excellent robustness with respect to distortions.

  3. On the population dose around the Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Hill, P.; Dederichs, H.; Ostapczuk, P.; Hille, R.; Artemev, O.; Ptitskaya, L.; Akhmetov, M.; Pivovarov, S.

    2002-01-01

    Since 1949 the Semipalatinsk Nuclear Test Site (NTS) was extensively used by the former Soviet government as a testing range for atomic weapons. Atmospheric and underground tests were finally stopped in 1962 and 1989, respectively. The Ministry of the Russian Federation of Atomic Energy officially counts a total of 456 tests, including 116 atmospheric tests. The total yield of the nuclear explosions carried out was 6.3 Megatons equivalent with 6.7 PetaBq of 1 37C s and 3.7 PetaBq of 9 0S r being released into the athmosphere. Some of the athmospheric radioactive tests shielded plumes, which extended far beyond the outer borders of the NTS. Already the first Soviet atomic bomb test on August 29, 1949 due to unfavourable meteorological conditions affected the villages of Dolon and Moistik. Since 1995 joint investigations performed by the Research Centre Julich in cooperation with the Kazakh National Nuclear Centre in the region of the former nuclear test site near Semipalatinsk besides environmental measurents also involve the assessment of the current dose of the population at and around the test site in addition to the important retrospective determination of the dose of persons affected by the atmospheric tests

  4. Dose-Weighted Adjusted Mantel-Haenszel Tests for Numeric Scaled Strata in a Randomized Trial

    Science.gov (United States)

    Gansky, Stuart A.; Cheng, Nancy F.; Koch, Gary G.

    2011-01-01

    A recent three-arm parallel groups randomized clinical prevention trial had a protocol deviation causing participants to have fewer active doses of an in-office treatment than planned. The original statistical analysis plan stipulated a minimal assumption randomization-based extended Mantel-Haenszel (EMH) trend test of the high frequency, low frequency, and zero frequency treatment groups and a binary outcome. Thus a dose-weighted adjusted EMH (DWAEMH) test was developed with an extra set of weights corresponding to the number of active doses actually available, in the spirit of a pattern mixture model. The method can easily be implemented using standard statistical software. A set of Monte Carlo simulations using a logistic model was undertaken with (and without) actual dose-response effects through 1000 replicates for empirical power estimates (and 2100 for empirical size). Results showed size was maintained and power was improved for DWAEMH versus EMH and logistic regression Wald tests in the presence of a dose effect and treatment by dose interaction. PMID:21709814

  5. Around Semipalatinsk nuclear test site: Progress of dose estimations relevant to the consequences of nuclear tests

    International Nuclear Information System (INIS)

    Stepanenko, Valeriy F.; Hoshi, Masaharu; Bailiff, Ian K.

    2006-01-01

    The paper is an analytical overview of the main results presented at the 3rd Dosimetry Workshop in Hiroshima (9-11 of March 2005), where different aspects of the dose reconstruction around the Semipalatinsk nuclear test site (SNTS) were discussed and summarized. The results of the international intercomparison of the retrospective luminescence dosimetry (RLD) method for Dolon' village (Kazakhstan) were presented at the Workshop and good concurrence between dose estimations by different laboratories from 6 countries (Japan, Russia, USA, Germany, Finland and UK) was pointed out. The accumulated dose values in brick for a common depth of 10 mm depth of 10 mm depth obtained independently by all participating laboratories were in good agreement for all four brick samples from Dolon' village, Kazakhstan, with the average value of the local gamma dose due to fallout (near the sampling locations) being about 220 mGy (background dose has been subtracted). Furthermore, using a conversion factor of about 2 to obtain the free-in-air dose, a value of local dose ∼440 mGy is obtained, which supports the results of external dose calculations for Dolon': recently published soil contamination data, archive information and new models were used for refining dose calculations and the external dose in air for Dolon village was estimated to be about 500 mGy. The results of electron spin resonance (ESR) dosimetry with tooth enamel have demonstrated the notable progress in application of ESR dosimetry to the problems of dose reconstruction around the Semipalatinsk nuclear test site. At the present moment, dose estimates by the ESR method have become more consistent with calculated values and with retrospective luminescence dosimetry data, but differences between ESR dose estimates and RLD/calculation data were noted. For example mean ESR dose for eligible tooth samples from Dolon' village was estimated to be about 140 mGy (above background dose), which is less than dose values obtained

  6. On the population dose close to the Semipalatinsk Nuclear Test Site

    International Nuclear Information System (INIS)

    Hill, P.; Peterson, L.; Pivovarov, S.; Rukhin, A.; Seredavina, T.; Sushkova, N.; Artemyev, O.; Abildinova, G.

    2008-01-01

    Full text: As a result of nuclear weapon tests at the Semipalatinsk Nuclear Test Site (SNTS) radiation exposure of inhabitants in surrounding villages has occurred over a period of several decades. Despite a number of published reports the determination of cumulative doses to the associated population and its uncertainty has not been finalized yet. Among the factors complicating this task are a) the time passed, b) the lack of direct personal dosimetry within the population possibly exposed, c) significant migration (out and in), d) inhomogeneous distribution of radionuclide deposition, e) new settlers at the SNTS and f) economic activities at the SNTS. This paper reports on the contribution of the ISTC-project K-465.2 'Complex examination of Semipalatinsk Test Site Region's population by advanced dosimetry methods' in assessing the population dose. The main results have been obtained during a period of three years by using the recent methodological progress made in EPR dosimetry on tooth enamel. Tooth enamel of people from settlements Dolon, Bodene, Cheremushki, Mostik, which were affected mainly by the first atomic explosion 1949, settlement Sarjal, affected by the first thermonuclear explosion in 1953, and as a control village Maysk, where radiological and meteorological records suggest that there was no significant radionuclide deposition near this village despite its position at the borders of SNTS, were investigated. Fresh tooth samples were used, which reflect well the current radiological situation. Additional measurements included e.g. environmental monitoring and in-vivo monitoring. EPR results suggest the existence of two sub-populations with different dose distributions: One with doses in the range of expected values from both natural background and SNTS testing, and another one with still higher doses not explained by the observed radioactive contamination. This finding is rather surprising. Additional research is needed to obtain a better statistic

  7. Surveys of radon levels in homes in the United States: A test of the linear-no-threshold dose-response relationship for radiation carcinogenesis

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1987-01-01

    The University of Pittsburgh Radon Project for large scale measurements of radon concentrations in homes is described. Its principal research is to test the linear-no threshold dose-response relationship for radiation carcinogenesis by determining average radon levels in the 25 U.S. counties (within certain population ranges) with highest and lowest lung cancer rates. The theory predicts that the former should have about 3 times higher average radon levels than the latter, under the assumption that any correlation between exposure to radon and exposure to other causes of lung cancer is weak. The validity of this assumption is tested with data on average radon level vs replies to items on questionnaires; there is little correlation between radon levels in houses and smoking habits, educational attainment, or economic status of the occupants, or with urban vs rural environs which is an indicator of exposure to air pollution

  8. Application of low dose multi-slice helical CT in orbital trauma patients

    International Nuclear Information System (INIS)

    Yang Rui; Dai Limei; Li Jianying; Wang Fengyan; Du Guoquan

    2010-01-01

    Objective: To investigate the most appropriate low radiation dose in multi-slice CT (MSCT) scans for orbital trauma patients. Methods: Thirty trauma patients with suspected orbital fractures who underwent helical CT scans with a 64-MSCT using regular dose were selected. Noise was artificially introduced to the axial images using an image space noise addition tool to simulate 6 sets of lower dose scans with tube current of 30, 70, 100, 140, 170 and 200 mA, respectively. The lowest tube current with adequate image quality for confident diagnosis was determined based on the evaluation of the overall image quality and fracture detection on images at different dose levels. The determined lowest tube current was then validated using clinical scans. Radiation dose related parameters CTDIvol, DLP, ED were also recorded. Image quality was evaluated according to its low-density resolution, noise and structure clarity and characterized into 5-grades of excellent, good, fair, worse and worst. Rank sum test and χ 2 test were used for statistics. Results: In 30 trauma patients with regular dose of 300 mA, there were 30 cases of orbital fracture, 19 cases of intraorbital emphysema, 12 cases of ocular muscle injury and 1 case of intraorbital foreign body. These changes could still be clearly observed and correctly diagnosed when the tube current was reduced to as low as 70 mA. However, the overall image quality was mostly fair. At the simulated dose of 100 mA, the majority of images were characterized as excellent or good, and there was no statistical difference compared with that of regular dose scans (P>0.05). In the clinical evaluation for 20 orbital trauma patients with the reduced tube current of 100 m A , the majority of images were judged to be excellent (9 cases) or good (17 cases) and fair (4 cases). The radiation dose (0.29 mSv) was reduced by 70% compared with that of regular tube current of 300 mA (0.86 mSv). Conclusion: The tube current of MSCT may be used as low as

  9. A summary of estimated doses to members of the public from atmospheric nuclear tests at the Nevada test site

    International Nuclear Information System (INIS)

    Simon, S.L.; Bouville, A.; Luckyanov, N.; Miller, C.W.; Beck, H.L.; Anspaugh, L.R.

    2002-01-01

    This paper discusses estimates of radiation dose to representative members of the public of the United States (U.S.) from atmospheric nuclear tests conducted from 1951 through 1962 at the Nevada Test Site. The estimates provided here summarize five studies conducted over the past two decades. From those studies, an estimate of the average deposition of 137 Cs within each of the more than 3,000 counties across the country has been derived as well as doses to representative persons in each county and to specific subpopulations. The years of the largest contributions to the collective external dose were 1952, 1953, and 1957. Those years accounted for about 70% of the 84,000 person-Gy received by the U.S. public. Irradiation of the thyroid gland of members of the U.S. public was also a consequence of dispersion of radioiodine in the fallout. Thyroid doses varied by location and by birth year. The population weighted thyroid dose for a child born in 1951 and for an adult in 1951 were 30 and 5 mGy, respectively. Maps are provided to show the geographic distribution of 137 Cs as well as the average thyroid dose received in each county from the Nevada tests. (author)

  10. Estimation of radionuclide ingestion: Lessons from dose reconstruction for fallout from the Nevada Test Site

    International Nuclear Information System (INIS)

    Breshears, D.D.; Whicker, F.W.; Kirchner, T.B.; Anspaugh, L.R.

    1994-01-01

    The United States conducted atmospheric testing of nuclear devices at the Nevada Test Site from 1951 through 1963. In 1979 the U.S. Department of Energy established the Off-Site Radiation Exposure Review Project to compile a data base related to health effects from nuclear testing and to reconstruct doses to public residing off of the Nevada Test Site. This project is the most comprehensive dose reconstruction project to date, and, since similar assessments are currently underway at several other locations within and outside the U.S., lessons from ORERP can be valuable. A major component of dose reconstruction is estimation of dose from radionuclide ingestion. The PATHWAY food-chain model was developed to estimate the amount of radionuclides ingested. For agricultural components of the human diet, PATHWAY predicts radionuclide concentrations and quantities ingested. To improve accuracy and model credibility, four components of model analysis were conducted: estimation of uncertainty in model predictions, estimation of sensitivity of model predictions to input parameters, and testing of model predictions against independent data (validation), and comparing predictions from PATHWAY with those from other models. These results identified strengths and weaknesses in the model and aided in establishing the confidence associated with model prediction, which is a critical component risk assessment and dose reconstruction. For fallout from the Nevada Test Site, by far, the largest internal doses were received by the thyroid. However, the predicted number of fatal cancers from ingestion dose was generally much smaller than the number predicted from external dose. The number of fatal cancers predicted from ingestion dose was also orders of magnitude below the normal projected cancer rate. Several lessons were learned during the study that are relevant to other dose reconstruction efforts

  11. Estimation of radiation dose received by the radiation workers during radiographic testing

    International Nuclear Information System (INIS)

    Mohammed, N. A. H. O.

    2013-08-01

    This study was conducted primarily to evaluate occupational radiation dose in industrial radiography during radiographic testing at Balil-Hadida, with the aim of building up baseline data on radiation exposure in the industrial radiography practice in Sudan. Dose measurements during radiographic testing were performed and compared with IAEA reference dose. In this research the doses measured by using hand held radiation survey meter and personal monitoring dosimeter. The results showed that radiation doses ranged between minimum (0.448 mSv/ 3 month) , and maximum (1.838 mSv / 3 month), with an average value (0.778 mSv/ 3 month), and the standard deviation 0.292 for the workers used gamma mat camera. The analysis of data showed that the radiation dose for all radiation worker are receives less than annual limit for exposed workers 20 mSv/ year and compare with other study found that the dose received while body doses ranging from 0.1 to 9.4 mSv/ year, work area design in all the radiography site followed the three standard rules namely putting radiation signs, reducing access to control area and making of boundaries. Thus the accidents arising from design faults not likely to occur at these site. Results suggest that adequate fundamental training of radiation workers in general radiography prior to industrial radiography work will further improve the standard of personnel radiation protection. (Author)

  12. Radiation doses and cancer risks in the Marshall Islands associated with exposure to radioactive fallout from Bikini and Enewetak nuclear weapons tests: summary.

    Science.gov (United States)

    Simon, Steven L; Bouville, André; Land, Charles E; Beck, Harold L

    2010-08-01

    Nuclear weapons testing conducted at Bikini and Enewetak Atolls during 1946-1958 resulted in exposures of the resident population of the present-day Republic of the Marshall Islands to radioactive fallout. This paper summarizes the results of a thorough and systematic reconstruction of radiation doses to that population, by year, age at exposure, and atoll of residence, and the related cancer risks. Detailed methods and results are presented in a series of companion papers in this volume. From our analysis, we concluded that 20 of the 66 nuclear tests conducted in or near the Marshall Islands resulted in measurable fallout deposition on one or more of the inhabited atolls of the Marshall Islands. In this work, we estimated deposition densities (kBq m(-2)) of all important dose-contributing radionuclides at each of the 32 atolls and separate reef islands of the Marshall Islands. Quantitative deposition estimates were made for 63 radionuclides from each test at each atoll. Those estimates along with reported measurements of exposure rates at various times after fallout were used to estimate radiation absorbed doses to the red bone marrow, thyroid gland, stomach wall, and colon wall of atoll residents from both external and internal exposure. Annual doses were estimated for six age groups ranging from newborns to adults. We found that the total deposition of 137Cs, external dose, internal organ doses, and cancer risks followed the same geographic pattern with the large population of the southern atolls receiving the lowest doses. Permanent residents of the southern atolls who were of adult age at the beginning of the testing period received external doses ranging from 5 to 12 mGy on average; the external doses to adults at the mid-latitude atolls ranged from 22 to 59 mGy on average, while the residents of the northern atolls received external doses in the hundreds to over 1,000 mGy. Internal doses varied significantly by age at exposure, location, and organ. Except

  13. Patient radiation dose during fluoroscopy testes with contrast medium

    International Nuclear Information System (INIS)

    Darsalih, Abir Abdelrady El noor

    2016-09-01

    The purpose of this study was to assess the patient radiation dose received in fluoroscopy examinations during contrast medium. The cumulative air kerma (Ck), kerma area product (KAP) and fluoroscopy time were measured for sixty ( male and female ) patients undergoing five fluoroscopy examinations KAP metre which was installed for the purpose of this study. The mean kerma area product were found to be 2.681, 5.1561, 9.85529. 5.7974 and 13.09 Gy.cm"2 for HSG, A.S and D.S, GI Track and sonogram tests, respectively. The obtained mean cumulative dose was were 6.31, 13.88, 24.61, 22.56 and 32.14 mGy for HSG, A.S, A.S and D.S , GI Track, respectively, the mean fluoroscopy time were. 0.18, 0.51,0.89,1.57 and 1.75 min, for HSG, A.S, A.S, and D.S, G1 Track and sonogram test respectively. Patient dose is mainly dependent on the patient size, procedure, equipment used exposure factor and user experience. As KV and mA were controlled by the AEC and it was found to be well calibrated, possible optimization could be achieved by radiologist by decreasing the exposure time if possible. (Author)

  14. High-dose calcium stimulation test in a case of insulinoma masquerading as hysteria.

    Science.gov (United States)

    Nakamura, Yoshio; Doi, Ryuichiro; Kohno, Yasuhiro; Shimono, Dai; Kuwamura, Naomitsu; Inoue, Koichi; Koshiyama, Hiroyuki; Imamura, Masayuki

    2002-11-01

    It is reported that some cases with insulinoma present with neuropsychiatric symptoms and are often misdiagnosed as psychosis. Here we report a case of insulinoma masquerading as hysteria, whose final diagnosis could be made using high-dose calcium stimulation test. A 28-yr-old woman was referred presenting with substupor, mutism, mannerism, restlessness, and incoherence. Laboratory examinations revealed hypoglycemia (33 mg/dL) and detectable insulin levels (9.7 microU/mL), suggesting the diagnosis of insulinoma. However, neither imaging studies nor selective arterial calcium injection (SACI) test with a conventional dose of calcium (0.025 mEq/kg) indicated the tumor. High-dose calcium injection (0.05 mEq/kg) evoked insulin secretion when injected into superior mesenteric artery. A solitary tumor in the head of the pancreas was resected, and her plasma glucose returned to normal. Postoperatively, iv injection of secretin resulted in a normal response of insulin, which was not found preoperatively. This case suggests the usefulness of the SACI test with high-dose of calcium in the case of insulinoma when the standard dose fails to detect such a tumor.

  15. Doses from external irradiation to Marshall Islanders from Bikini and Enewetak nuclear weapons tests.

    Science.gov (United States)

    Bouville, André; Beck, Harold L; Simon, Steven L

    2010-08-01

    Annual doses from external irradiation resulting from exposure to fallout from the 65 atmospheric nuclear weapons tests conducted in the Marshall Islands at Bikini and Enewetak between 1946 and 1958 have been estimated for the first time for Marshallese living on all inhabited atolls. All tests that deposited fallout on any of the 23 inhabited atolls or separate reef islands have been considered. The methodology used to estimate the radiation doses at the inhabited atolls is based on test- and location-specific radiation survey data, deposition density estimates of 137Cs, and fallout times-of-arrival provided in a companion paper (Beck et al.), combined with information on the radionuclide composition of the fallout at various times after each test. These estimates of doses from external irradiation have been combined with corresponding estimates of doses from internal irradiation, given in a companion paper (Simon et al.), to assess the cancer risks among the Marshallese population (Land et al.) resulting from exposure to radiation from the nuclear weapons tests.

  16. Dose reduction in evacuation proctography

    International Nuclear Information System (INIS)

    Hare, C.; Halligan, S.; Bartram, C.I.; Gupta, R.; Walker, A.E.; Renfrew, I.

    2001-01-01

    The goal of this study was to reduce the patient radiation dose from evacuation proctography. Ninety-eight consecutive adult patients referred for proctography to investigate difficult rectal evacuation were studied using a digital imaging system with either a standard digital program for barium examinations, a reduced dose digital program (both with and without additional copper filtration), or Video fluoroscopy. Dose-area products were recorded for each examination and the groups were compared. All four protocols produced technically acceptable examinations. The low-dose program with copper filtration (median dose 382 cGy cm 2 ) and Video fluoroscopy (median dose 705 cGy cm 2 ) were associated with significantly less dose than other groups (p < 0.0001). Patient dose during evacuation proctography can be reduced significantly without compromising the diagnostic quality of the examination. A digital program with added copper filtration conveyed the lowest dose. (orig.)

  17. Review of proton pump inhibitors for the initial treatment of heartburn: is there a dose ceiling effect?

    Science.gov (United States)

    Kushner, Pamela R; Peura, David A

    2011-05-01

    Proton pump inhibitors (PPIs) are widely used in clinical practice. However, concerns have been expressed about their long-term use, particularly with regard to bone health, Clostridium difficile infections, and drug interactions with platelet aggregation inhibitors. There has been limited guidance for clinicians concerning appropriate dose selection of PPIs for the initial treatment of heartburn. This review explored whether published clinical trials provide evidence of a ceiling above which higher PPI doses do not provide additional clinical benefit over the lowest approved dose. All articles of randomized, controlled clinical trials in nonerosive gastroesophageal reflux disease (GERD) in which the effects of two or more doses of the same PPI on symptomatic relief of heartburn were quantified as a study endpoint were identified and analyzed through PubMed searches up to the end of September 2010. The majority of trials evaluated provided no evidence that higher PPI doses were superior to the lowest approved dose for the initial treatment of heartburn. There were no clinically relevant findings with respect to dose dependence and safety outcomes in these studies. Efficacy outcomes from the trials suggest there may be a dose ceiling effect and highlight the need for further research on the use of the lowest effective PPI doses as an appropriate strategy in the initial treatment of uncomplicated heartburn. Observational studies and some meta-analyses have suggested that long-term PPI pharmacotherapy might be associated with safety concerns, which necessitate the periodic evaluation of therapeutic benefit in terms of symptom resolution and regimen tolerability. However, evidence to date suggests that use of the lowest effective dose for the indication is not associated with significant adverse events, particularly in the short term. Clinical practice suggests that patients requiring long-term treatment should be maintained on the lowest dose necessary to control

  18. Low-dose effect of developmental bisphenol A exposure on sperm count and behaviour in rats

    DEFF Research Database (Denmark)

    Hass, Ulla; Christiansen, Sofie; Boberg, Julie

    2016-01-01

    /day. In the offspring, growth, sexual maturation, weights and histopathology of reproductive organs, oestrus cyclicity and sperm counts were assessed. Neurobehavioural development was investigated using a behavioural testing battery including tests for motor activity, sweet preference, anxiety and spatial learning....... Decreased sperm count was found at the lowest bisphenol A dose, that is 25 μg/kg/day, but not at the higher doses. Reproductive organ weight and histology were not affected and no behavioural effects were seen in male offspring. In the female offspring, exposure to 25 μg/kg bw/day bisphenol A dose resulted...... not significantly affected. In conclusion, the present study using a robust experimental study design, has shown that developmental exposure to 25 μg/kg bw/day bisphenol A can cause adverse effects on fertility (decreased sperm count), neurodevelopment (masculinization of spatial learning in females) and lead...

  19. Estimated of associated uncertainties of the linearity test of dose calibrators; Estimativa das incertezas associadas ao teste de linearidade de calibradores de dose

    Energy Technology Data Exchange (ETDEWEB)

    Sousa, Carlos H.S.; Peixoto, Jose G.P., E-mail: chenrique@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), RIo de Janeiro, RJ (Brazil)

    2013-07-01

    Activimeters determine the activity of radioactive samples and them are validated by performance tests. This research determined the expanded uncertainties associated to the linearity test. Were used three dose calibrators and three sources of {sup 99}Tc{sup m} for testing using recommended protocol by the IAEA, which considered the decay of radioactive samples. The expanded uncertainties evaluated were not correlated with each other and their analysis considered a rectangular probability distribution. The results are also presented in graphical form by the function of normalized activity measured in terms of conventional true value. (author)

  20. Why low doses at Finnish NPPs?

    International Nuclear Information System (INIS)

    Wahlstroem, B.; Vaehaemaa, T.

    1995-01-01

    The Finnish nuclear power units - two BWRs (ABB Atom) and two PWRs (VVER) -are known for their high load factors. Finland's reactors have topped the world ranking list for more than ten years. This explains why their collective radiation doses are among the lowest in the world. During normal operation a collective dose of less than ten millisieverts per month is received at one site

  1. Europe the continent with the lowest fertility

    NARCIS (Netherlands)

    Baird, D. T.; Collins, J.; Evers, J. L. H.; Leridon, H.; Lutz, W.; Velde, E. Te; Thevenon, O.; Crosignani, P. G.; Devroey, P.; Diedrich, K.; Fauser, B. C. J. M.; Fraser, L.; Geraedts, J. P. M.; Gianaroli, L.; Glasier, A.; Sunde, A.; Tarlatzis, B.; Van Steirteghem, A.; Veiga, A.

    2010-01-01

    INTRODUCTION: Although fertility rates are falling in many countries, Europe is the continent with the lowest total fertility rate (TFR). This review assesses trends in fertility rates, explores possible health and social factors and reviews the impact of health and social interventions designed to

  2. Peripheral dose to the testes: the design and clinical use of a practical and effective gonadal shield

    International Nuclear Information System (INIS)

    Fraass, B.A.; Kinsella, T.J.; Harrington, F.S.; Galtstein, E.

    1985-01-01

    A simple and practical gonadal shield has been developed for use near megavoltage radiation fields. The lead shield encloses only the testes, allowing its use with nearly any radiation field that does not include the testes. The dose to the testes with and without the shield has been measured extensively both in phantoms and on patients. The gonadal shield allows a 3 to 10-fold reduction in dose to the testes depending primarily on the distance from the field edge to the gonads. When the shield is used, the gonadal dose is always less than 1% of the patient's prescription dose. Based on our patient studies of testicular injury following conventionally-fractionated irradiation, a dose of less than 50 cGy should preserve normal testicular function

  3. Organ doses from computerized tomography examinations

    Energy Technology Data Exchange (ETDEWEB)

    Janeczek, J.

    1995-12-31

    Estimates of mean organs doses from five typical computerized tomography (CT) examinations were obtained. Measurements were done using Rando-Alderson anthropomorphic phantom and thermoluminescent dosemeters (TLD). Radiation dose distributions within a phantom has been measured for each examination and results were used for organ dose calculation. Doses to organs specified by ICPR 60 Recommendations were measured for five CT scanners (CT/T8800, CT 9800, CT MAX - made by General Electric; CT 1200 SX - made by Picker; SOMATOM 2 - made by Siemens). Dose distributions from scattered radiation were measured and indicate that scattered radiation dose to thyroid and eye lens can be reduced by proper examination limits setting. The lowest mean organ doses were obtained from CT/T8800 scanner. More advanced scanners using high intensity continuous radiation were giving higher organ doses. (author). 23 refs, 6 figs, 13 tabs.

  4. Organ doses from computerized tomography examinations

    International Nuclear Information System (INIS)

    Janeczek, J.

    1995-01-01

    Estimates of mean organs doses from five typical computerized tomography (CT) examinations were obtained. Measurements were done using Rando-Alderson anthropomorphic phantom and thermoluminescent dosemeters (TLD). Radiation dose distributions within a phantom has been measured for each examination and results were used for organ dose calculation. Doses to organs specified by ICPR 60 Recommendations were measured for five CT scanners (CT/T8800, CT 9800, CT MAX - made by General Electric; CT 1200 SX - made by Picker; SOMATOM 2 - made by Siemens). Dose distributions from scattered radiation were measured and indicate that scattered radiation dose to thyroid and eye lens can be reduced by proper examination limits setting. The lowest mean organ doses were obtained from CT/T8800 scanner. More advanced scanners using high intensity continuous radiation were giving higher organ doses. (author). 23 refs, 6 figs, 13 tabs

  5. Peripheral dose to the testes: the design and clinical use of a practical and effective gonadal shield.

    Science.gov (United States)

    Fraass, B A; Kinsella, T J; Harrington, F S; Glatstein, E

    1985-03-01

    A simple and practical gonadal shield has been developed for use near megavoltage radiation fields. The lead shield encloses only the testes, allowing its use with nearly any radiation field that does not include the testes. The dose to the testes with and without the shield has been measured extensively both in phantoms and on patients. The gonadal shield allows a 3 to 10-fold reduction in dose to the testes depending primarily on the distance from the field edge to the gonads. When the shield is used, the gonadal dose is always less than 1% of the patient's prescription dose. Based on our patient studies of testicular injury following conventionally-fractionated irradiation, a dose of less than 50 cGy (1% of a typical 5000 cGy treatment regimen) should preserve normal testicular function.

  6. Estimation of average glandular dose depending on the thickness of the breast; Estimativa da dose glandular media em funcao da espessura da mama

    Energy Technology Data Exchange (ETDEWEB)

    Real, Jessica V.; Luz, Renata M. da, E-mail: jessica.real@pucrs.br, E-mail: renata.luz@pucrs.br [Hospital Sao Lucas (HSL/PUCRS), Porto Alegre, RS (Brazil); Fröhlich, Bruna D.; Pertile, Alessandra S.; Silva, Ana Maria Marques da, E-mail: bruna.frohlich@acad.pucrs.br, E-mail: lessandra.pertile@acad.pucrs.br, E-mail: ana.marques@pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre, RS (Brazil)

    2014-07-01

    Breast cancer is the most common type of cancer in women worldwide. Mammography is, to date, the most efficient method for detecting an abnormality in the patient's breast. It is a technique of imaging diagnostic that requires special care because radiographs without adequate quality may lead to a false diagnosis and lead to the need for a repeat examination, increasing the dose of radiation in the patient. This study aimed to evaluate the average glandular dose (AGD), depending on the breast thickness in patients undergoing routine tests, with a digital computer radiography processing system. Analyzed 30 exhibitions in patients aged (65 ± 12) years, in the right and left caudal skull projections, for breasts with thicknesses between 45 mm and 50 mm. The calculated value of the AGD for this track thickness was (1.600 ± 0.009) mGy. The performance of mammography quality control tests was satisfactory and the AGD values obtained for the chosen thickness range is acceptable, since the threshold achievable is 1.6 mGy and the acceptable is 2 mGy. In Brazil, it is only required the input dose calculation in skin for 45 mm breasts. However, the calculation of AGD is required for different thicknesses of the breast, to identify the best mammographic pattern aiming at better image quality at the lowest dose provided the patient.

  7. Utilization of urea micro dose with 14 C in breath test to detect the Helicobacter pylori

    International Nuclear Information System (INIS)

    Chausson, Yvon; Coelho, Luiz Gonzaga V.; Passos, Maria do Carmo F.; Andrade, Angela A.M.; Simal, Carlos J.R.; Paula Castro, Luiz de; Fernandes, M.L.; Yazaki, F.R.

    1995-01-01

    A lower dose is used in the 14 C-urea breath test to detect the Helicobacter pylori (Hp). Such dose produce trivial radiation doses. The results shown that the use of this desirable dose is possible. (author). 4 refs., 1 fig

  8. Patch test dose-response study of p-phenylenediamine

    DEFF Research Database (Denmark)

    Sosted, Heidi; Menné, Torkil; Johansen, Jeanne Duus

    2006-01-01

    The elicitation response in allergic contact dermatitis for the hair dye substance p-phenylenediamine (PPD) is dose dependent, but threshold concentrations have not previously been investigated. 15 PPD-sensitive patients participated in a serial dilution 48-hr patch test with PPD using 8...... concentrations of PPD ranging from 1 to 10 000 on the upper back. Petrolatum was applied as control. Three concentrations (50, 100 and 500 p.p.m. PPD) were also applied to the retroauricular area and on the lateral aspects of the upper arms. 14 of the 15 participants reacted to one or more of the test samples....... The threshold value for 10% of the tested persons (ED10) based on+or stronger reactions for PPD on the back was 38 p.p.m. (CI: 4.3-100). There were no statistically significant differences in the sensitivity of the three anatomical regions. The upper back is a suitable region for patch testing patients...

  9. Dose Response of MARV/Angola Infection in Cynomolgus Macaques following IM or Aerosol Exposure

    Science.gov (United States)

    Johnston, Sara C.; Lin, Kenny L.; Twenhafel, Nancy A.; Raymond, Jo Lynne W.; Shamblin, Joshua D.; Wollen, Suzanne E.; Wlazlowski, Carly B.; Wilkinson, Eric R.; Botto, Miriam A.; Goff, Arthur J.

    2015-01-01

    Marburg virus infection in humans causes a hemorrhagic disease with a high case fatality rate. Countermeasure development requires the use of well-characterized animal models that mimic human disease. To further characterize the cynomolgus macaque model of MARV/Angola, two independent dose response studies were performed using the intramuscular or aerosol routes of exposure. All animals succumbed at the lowest target dose; therefore, a dose effect could not be determined. For intramuscular-exposed animals, 100 PFU was the first target dose that was not significantly different than higher target doses in terms of time to disposition, clinical pathology, and histopathology. Although a significant difference was not observed between aerosol-exposed animals in the 10 PFU and 100 PFU target dose groups, 100 PFU was determined to be the lowest target dose that could be consistently obtained and accurately titrated in aerosol studies. PMID:26413900

  10. Dose Response of MARV/Angola Infection in Cynomolgus Macaques following IM or Aerosol Exposure.

    Directory of Open Access Journals (Sweden)

    Sara C Johnston

    Full Text Available Marburg virus infection in humans causes a hemorrhagic disease with a high case fatality rate. Countermeasure development requires the use of well-characterized animal models that mimic human disease. To further characterize the cynomolgus macaque model of MARV/Angola, two independent dose response studies were performed using the intramuscular or aerosol routes of exposure. All animals succumbed at the lowest target dose; therefore, a dose effect could not be determined. For intramuscular-exposed animals, 100 PFU was the first target dose that was not significantly different than higher target doses in terms of time to disposition, clinical pathology, and histopathology. Although a significant difference was not observed between aerosol-exposed animals in the 10 PFU and 100 PFU target dose groups, 100 PFU was determined to be the lowest target dose that could be consistently obtained and accurately titrated in aerosol studies.

  11. Neutron dose rate at the SwissFEL injector test facility: first measurements

    International Nuclear Information System (INIS)

    Hohmann, E.; Frey, N.; Fuchs, A.; Harm, C.; Hoedlmoser, H.; Luescher, R.; Mayer, S.; Morath, O.; Philipp, R.; Rehmann, A.; Schietinger, T.

    2014-01-01

    At the Paul Scherrer Institute, the new SwissFEL Free Electron Laser facility is currently in the design phase. It is foreseen to accelerate electrons up to a maximum energy of 7 GeV with a pulsed time structure. An injector test facility is operated at a maximum energy of 300 MeV and serves as the principal test and demonstration plant for the SwissFEL project. Secondary radiation is created in unavoidable interactions of the primary beam with beamline components. The resulting ambient dose-equivalent rate due to neutrons was measured along the beamline with different commercially available survey instruments. The present study compares the readings of these neutron detectors (one of them is specifically designed for measurements in pulsed fields). The experiments were carried out in both, a normal and a diagnostic mode of operation of the injector. Measurements were taken at the SwissFEL injector test facility using three different types of commercially available survey instruments for normal and diagnostic mode of operation at different positions inside the accelerator vault. During normal operation, the doses indicated by the different instruments agree within the measurement uncertainty except for the beam dump region. There, due to its limited energy range and high sensitivity, the LB6411 shows significantly lower dose values than the other instruments. The photon background in the vault associated with each pulse causes the scintillator used by the LB6419 to saturate. As a result, only the channel using the delayed 12 C(n,p)12-reaction could be used during the measurements. The highest doses per pulse were measured next to the beam dump and the bunch compressor. For the optimisation of the accelerator, luminescent screens can be inserted into the beam path causing a dose distributed over several metres depending on the screen type. The dose arise to 40 % from neutrons with energies of >20 MeV. Although the charge of each pulse were reduced to decrease

  12. Patch test concentrations (doses in mg/cm2 ) for the 12 non-mix fragrance substances regulated by European legislation.

    Science.gov (United States)

    Bruze, Magnus; Svedman, Cecilia; Andersen, Klaus Ejner; Bruynzeel, Derk; Goossens, An; Johansen, Jeanne Duus; Matura, Mihaly; Orton, David; Vigan, Martine

    2012-03-01

    According to EU legislation, 26 fragrance substance allergens must be labelled on cosmetic products. For 12 of them, the optimal patch test concentration/dose has not been evaluated. To establish the optimal patch test doses in mg/cm2 for the 12 fragrance substances that are not included in fragrance mix I or II in the European baseline patch test series. Patch testing with the 12 fragrance substances was performed in a stepwise manner encompassing up to five rounds in at least 100 dermatitis patients for each round. Before patch testing, an individual maximum concentration/dose was determined for each fragrance substance. The predetermined maximum patch test concentrations/doses could be tested for all 12 fragrance substances, with no observable adverse reactions being noted. For each fragrance substance investigated, it is recommended that half of the maximum patch test dose (mg/cm2) be used for aimed and screening patch testing. © 2012 John Wiley & Sons A/S.

  13. Low-dose caffeine discrimination and self-reported mood effects in normal volunteers.

    Science.gov (United States)

    Silverman, K; Griffiths, R R

    1992-01-01

    A caffeine versus placebo discrimination procedure was used to determine the lowest caffeine dose that could produce discrimination and self-reported mood effects in normal volunteers. During daily sessions under double-blind conditions, caffeine-abstinent subjects orally ingested a capsule containing 178 mg caffeine or placebo. Before beginning discrimination training, the compounds were identified to subjects by letter codes. Fifteen, 30, and 45 min after capsule ingestion, subjects guessed the capsule's letter code. Correct guesses at 45 min earned money. After each session, subjects received a supplementary capsule containing caffeine or placebo to ensure that, within each phase of the study, subjects received the same daily dose of caffeine equal to the training dose. Five of the 15 subjects acquired the caffeine versus placebo discrimination within the first 20 sessions (greater than or equal to 75% correct); 6 other subjects acquired the discrimination with additional training. Nine subjects who acquired the discrimination were subsequently trained at progressively lower caffeine doses. In general, the lowest dose to produce discrimination (greater than or equal to 75% correct) was also the lowest dose to produce self-reported mood effects: 4 subjects showed discrimination and self-reported mood effects at 100 mg caffeine, 2 at 56 mg, 1 at 32 mg, and 1 at 18 mg. One of these subjects also showed self-reported mood effects at 10 mg. The present study documents discriminative stimulus and self-reported mood effects of caffeine at doses below those previously shown to affect any behavior in normal volunteers. PMID:1548451

  14. Dose rate and dose fractionation studies in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Netzel, B.; Schaffer, E.; Kolb, H.

    1979-01-01

    Total body irradiation (TBI) with 800-900 rads and allogeneic bone marrow transplantation according to the regimen designated by the Seattle group has induced remissions in patients with otherwise refractory acute leukemias. Relapse of leukemia after bone marrow transplantation remains the major problem, when the Seattle set up of two opposing 60 Co-sources and a low dose rate is used in TBI. Studies in dogs with TBI at various dose rates confirmed observations in mice that gastrointestinal toxicity is unlike toxicity against hemopoietic stem cells and possibly also leukemic stem cells depending on the dose rate. However, following very high single doses (2400 R) and marrow infusion acute gastrointestinal toxicity was not prevented by the lowest dose rate studied (0.5 R/min). Fractionated TBI with fractions of 600 R in addition to 1200 R (1000 rads) permitted the application of total doses up to 300 R followed by marrow infusion without irreversible toxicity. 26 dogs given 2400-3000 R have been observed for presently up to 2 years with regard to delayed radiation toxicity. This toxicity was mild in dogs given single doses at a low dose rate or fractionated TBI. Fractionated TBI is presently evaluated with allogeneic transplants in the dog before being applied to leukemic patients

  15. Effects of Gamma Irradiation and Dose Accumulation on the Histology of Spodoptera littoralis (Boisd.) Male Testes

    International Nuclear Information System (INIS)

    Sallam, H.A.; El-Naggar, S.E.M.; Shibel, M.M.; El-Dossouki, S.A.

    2000-01-01

    Full-grown male pupae of the cotton leaf worm Spodoptera littoralis (Boisd.) were gamma irradiated with low doses of 25, 50, 75 or 100 Gy. The effects of accumulating doses applied to these pupae through three consequent filial generations and the retarded influence on their F 1 , F 2 and F 3 generations progeny were examined. The histological observations showed that the damage in the testes was correlated with increasing the dose applied to the male parents and was the highest among the adults of F 1 . Also, the damage at any acute dose was less than the damage occurred in the same accumulated dose. The deteriorations on the testes were more evident in case of F 1 males resulting from parental males irradiated through two or three successive generations or three accumulated doses of 25 or 50 Gy

  16. Dose-Time Effect of Crude Oil and Hydro-test Effluent on Freshwater ...

    African Journals Online (AJOL)

    This work was undertaken to investigate the dose-time effect of crude oil and hydro-test effluent on freshwater and brackish water habitats. The species used for the acute toxicity were freshwater fish, Tilapia guineenis (fry) and a brackish water shrimp, Palaemonetes africanus. Test results indicated that the brackish water ...

  17. Iron prophylaxis during pregnancy -- how much iron is needed? A randomized dose- response study of 20-80 mg ferrous iron daily in pregnant women

    DEFF Research Database (Denmark)

    Milman, Nils; Bergholt, Thomas; Eriksen, Lisbeth

    2005-01-01

    To determine the lowest dose of iron preventative of iron deficiency and iron deficiency anemia in pregnancy.......To determine the lowest dose of iron preventative of iron deficiency and iron deficiency anemia in pregnancy....

  18. Excitation of lowest electronic states of thymine by slow electrons

    Science.gov (United States)

    Chernyshova, I. V.; Kontros, E. J.; Markush, P. P.; Shpenik, O. B.

    2013-11-01

    Excitation of lowest electronic states of the thymine molecules in the gas phase is studied by elec- tron energy loss spectroscopy. In addition to dipole-allowed transitions to singlet states, transitions to the lowest triplet states were observed. The low-energy features of the spectrum at 3.66 and 4.61 eV are identified with the excitation of the first triplet states 13 A' (π → π*) and 13 A″ ( n → π*). The higher-lying features at 4.96, 5.75, 6.17, and 7.35 eV are assigned mainly to the excitation of the π → π* transitions to the singlet states of the molecule. The excitation dynamics of the lowest states is studied. It is found that the first triplet state 13 A'(π → π*) is most efficiently excited at a residual energy close to zero, while the singlet 21 A'(π → π*) state is excited with almost identical efficiency at different residual energies.

  19. Blueberry Galaxies: The Lowest Mass Young Starbursts

    Science.gov (United States)

    Yang, Huan; Malhotra, Sangeeta; Rhoads, James E.; Wang, Junxian

    2017-09-01

    Searching for extreme emission line galaxies allows us to find low-mass metal-poor galaxies that are good analogs of high redshift Lyα emitting galaxies. These low-mass extreme emission line galaxies are also potential Lyman-continuum leakers. Finding them at very low redshifts (z≲ 0.05) allows us to be sensitive to even lower stellar masses and metallicities. We report on a sample of extreme emission line galaxies at z≲ 0.05 (blueberry galaxies). We selected them from SDSS broadband images on the basis of their broadband colors and studied their properties with MMT spectroscopy. From the entire SDSS DR12 photometric catalog, we found 51 photometric candidates. We spectroscopically confirm 40 as blueberry galaxies. (An additional seven candidates are contaminants, and four remain without spectra.) These blueberries are dwarf starburst galaxies with very small sizes (<1 kpc) and very high ionization ([O III]/[O II] ˜ 10-60). They also have some of the lowest stellar masses ({log}(M/{M}⊙ )˜ 6.5{--}7.5) and lowest metallicities (7.1< 12+{log}({{O}}/{{H}})< 7.8) of starburst galaxies. Thus, they are small counterparts to green pea galaxies and high redshift Lyα emitting galaxies.

  20. Radiation dose-reduction strategies in thoracic CT.

    Science.gov (United States)

    Moser, J B; Sheard, S L; Edyvean, S; Vlahos, I

    2017-05-01

    Modern computed tomography (CT) machines have the capability to perform thoracic CT for a range of clinical indications at increasingly low radiation doses. This article reviews several factors, both technical and patient-related, that can affect radiation dose and discusses current dose-reduction methods relevant to thoracic imaging through a review of current techniques in CT acquisition and image reconstruction. The fine balance between low radiation dose and high image quality is considered throughout, with an emphasis on obtaining diagnostic quality imaging at the lowest achievable radiation dose. The risks of excessive radiation dose reduction are also considered. Inappropriately low dose may result in suboptimal or non-diagnostic imaging that may reduce diagnostic confidence, impair diagnosis, or result in repeat examinations incurring incremental ionising radiation exposure. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. High-resolution CT of the lung in asbestos-exposed subjects. Comparison of low-dose and high-dose HRCT

    International Nuclear Information System (INIS)

    Majurin, M.L.; Varpula, M.; Kurki, T.; Pakkala, L.

    1994-01-01

    The lowest possible mAs settings for high-resolution CT (HRCT) were studied on 45 individuals with suspected asbestos-related lung disease. All patients were investigated with 5 to 6 high-dose HRCT images (120 kVp/160 mA/2 s) at 3-cm intervals. At a selected level 4 additional low-dose images were obtained on each patient with lower mAs settings (100 mA/2 s, 80 mA/2 s, 60 mA/2 s, 30 mA/2 s). Thirty-seven subjects out of 45 had HRCT lesions compatible with asbestosis. HRCT images obtained with as low as 60 mA/2 s settings clearly showed pleural tractions and thickenings, parenchymal bands, honeycombing and subpleural curvilinear shadows, whereas in the evaluation of subpleural short lines and ground glass findings 80 mA/2 s were required. The lowest setting, 30 mA/2 s, was sufficient only in detecting and evaluating pleural tractions and thickenings. We conclude that 160 mAs yield good quality HRCT images, with substantial decrease of radiation dose, for the evaluation of asbestos-related lesions. (orig.)

  2. Effect of low dose Lead (Pb) administration on tail immersion test ...

    African Journals Online (AJOL)

    Effect of low dose Lead (Pb) administration on tail immersion test and ... subtle decline in cognitive function, and adverse reproductive outcome at low blood Pb level. ... Twenty adult Wistar rats of both sexes (weight 150g to 200g) were used.

  3. Estimate of whole body doses for Lynette Tew and Becky Farnsworth from Nevada Test Site local fallout

    International Nuclear Information System (INIS)

    Anspaugh, L.R.; Ng, Y.C.

    1985-01-01

    Lynette Tew and Becky Farnsworth are decendents whose relatives are litigants in Timothy vs US. The litigants allege that the decendents were harmed by radiation doses received as a result of local fallout from the testing of nuclear weapons at the Nevada Test Site. We have calculated a best estimate of the whole body dose received by each decendent from external exposure and the ingestion of radionuclides with food. In each case the dose via ingestion is trivial compared to the external dose. For Lynette Tew the dose estimate is 0.28 rads. For Becky Farnsworth it is 0.0035 rads. 23 references, 4 tables

  4. Performance of an automatic dose control system for CT. Specifications and basic phantom tests

    Energy Technology Data Exchange (ETDEWEB)

    Nagel, H.D. [Wissenschaft und Technik fuer die Radiolgoe, Dr. HD Nagel, Buchholz (Germany); Stumpp, P.; Kahn, T.; Gosch, D. [Universitaetsklinikum Leipzig (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie

    2011-01-15

    Purpose: To assess the performance and to provide more detailed insight into the characteristics and limitations of devices for automatic dose control (ADC) in CT. Materials and Methods: A comprehensive study on DoseRight 2.0, the ADC system provided by Philips for its Brilliance CT scanners, was conducted. Phantom tests were carried out on a 64-slice scanner (Brilliance 64) using assorted quality control (QC) phantoms that allowed verification of the basic specifications. If feasible, the findings were verified by model calculations based on known specifications. Results: For all tests, the dose reductions and modulation characteristics fully met the values expected from the specifications. Adverse effects due to increased image noise were only moderate as a result of the 'adequate noise system' design that employs comparatively gentle modulation, and the additional use of adaptive filtration. Conclusion: Simple tests with QC phantoms allow evaluation of the most relevant characteristics of devices for ADC in CT. (orig.)

  5. Synergistic Effects of Ad-Libitum Low-Dose Fructose Drinking and Low-Dose Streptozotocin Treatment in Wistar Rats: A Mild Model of Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Asie Sadeghi

    2017-07-01

    Full Text Available To develop a convenient animal model of T2D by pretreatment with low-dose 10% w/v fructose (FRC solution followed by the injection of low doses of streptozotocin (STZ in Wistar rats. For this 8-week experimental study; rats were first fed a standard chow ad-libitum diet and either tap water (n=40 or 10% w/v FRC solution (n=40 for 4 weeks. Next, rats in each category were randomly allocated to 4 subgroups (n=10 each of low-dose STZ (25,35, and 45 mg/kg. The final mean fasting blood sugar (FBG of FRC+STZ45 (197±55.87 mg/dl were significantly higher than that of the STZ45 (P=0.015 and FRC (P=0.019 groups. FRC+STZ45 showed the highest insulin resistance demonstrated by insulin tolerance test [area under the curve (AUC of insulin tolerance test; P<0.05]. AUC was not significantly different between the STZ45 and non-STZ groups and between FRC and non-FRC fed groups. Furthermore, FBG levels did not differ between FRC and non-FRC groups. Body weight measurement showed that the FRC+STZ45 group had the lowest body weight compared to all other groups. Our data provide the evidence that FRC and STZ45 synergistically could induce hyperglycemia and insulin resistance in Wistar rats. Here we presented a feasible model for initial forms of T2D by employing pretreatment with low-dose FRC solution and treatment with low-dose STZ.

  6. A Computational Tool for Testing Dose-related Trend Using an Age-adjusted Bootstrap-based Poly-k Test

    Directory of Open Access Journals (Sweden)

    Hojin Moon

    2006-08-01

    Full Text Available A computational tool for testing for a dose-related trend and/or a pairwise difference in the incidence of an occult tumor via an age-adjusted bootstrap-based poly-k test and the original poly-k test is presented in this paper. The poly-k test (Bailer and Portier 1988 is a survival-adjusted Cochran-Armitage test, which achieves robustness to effects of differential mortality across dose groups. The original poly-k test is asymptotically standard normal under the null hypothesis. However, the asymptotic normality is not valid if there is a deviation from the tumor onset distribution that is assumed in this test. Our age-adjusted bootstrap-based poly-k test assesses the significance of assumed asymptotic normal tests and investigates an empirical distribution of the original poly-k test statistic using an age-adjusted bootstrap method. A tumor of interest is an occult tumor for which the time to onset is not directly observable. Since most of the animal carcinogenicity studies are designed with a single terminal sacrifice, the present tool is applicable to rodent tumorigenicity assays that have a single terminal sacrifice. The present tool takes input information simply from a user screen and reports testing results back to the screen through a user-interface. The computational tool is implemented in C/C++ and is applied to analyze a real data set as an example. Our tool enables the FDA and the pharmaceutical industry to implement a statistical analysis of tumorigenicity data from animal bioassays via our age-adjusted bootstrap-based poly-k test and the original poly-k test which has been adopted by the National Toxicology Program as its standard statistical test.

  7. Effects of linuron on a rooted aquatic macrophyte in sediment-dosed test systems

    NARCIS (Netherlands)

    Buresova, H.; Crum, S.J.H.; Belgers, J.D.M.; Adriaanse, P.I.; Arts, G.H.P.

    2013-01-01

    Effects of linuron on the sediment-rooted aquatic macrophyte Myriophyllum spicatum L. were studied in sediment-dosed test systems following a proposed guideline with extended test duration. Sediment, pore water, overlying water and macrophyte shoots were sampled weekly for chemical analyses. Linuron

  8. Is action potential threshold lowest in the axon?

    NARCIS (Netherlands)

    Kole, Maarten H. P.; Stuart, Greg J.

    2008-01-01

    Action potential threshold is thought to be lowest in the axon, but when measured using conventional techniques, we found that action potential voltage threshold of rat cortical pyramidal neurons was higher in the axon than at other neuronal locations. In contrast, both current threshold and voltage

  9. Evaluation of the anode heel effect on the testes dose during pelvic radiography

    Directory of Open Access Journals (Sweden)

    Vahid Karami

    2017-05-01

    Full Text Available Background: Anode heel effect refers to reduction of radiation intensity in the anode side of X-ray tube. This variation in radiation intensity across the anode-cathode of X-ray tube can be benefited for decrease radiation exposure in some radiological examinations. The aim of this study was to evaluate the effect of anode heel orientation on the radiation dose received by the testes in male patients undergoing pelvic radiography. Methods: This is a cross-sectional study, conducted at one of the teaching hospitals of Ahvaz, Jundishapur University of Medical Science Ahvaz, Iran, from September 2015 to March 2016. In order to measure the profile of radiation intensity variation, 13 paired sets of high radiosensitive cylindrical lithium fluoride thermo-luminescent dosimeters (TLD aligned on the cathode-anode central axis upon the table and then irradiated using routine exposure parameters. The anode of X-ray tube was positioned toward the feet for 40 patients and toward the head for 39 patients undergoing pelvic radiography. For measure the entrance skin dose (ESD, 8 TLD chips were located on the central point of the radiation field and 5 TLDs were located on the testes position to measure the dose received. Results: Radiation intensity profile showed that radiation intensity decrease from the cathode to the anode side. Discrepancy of radiation intensity on central axis of cathode-anode was calculated about 35%. The radiation dose received by the testes was 26.74% lower for patients the anode directed toward the feet, compared to the patients in which the anode directed toward the head (FTC: 1.260±0.296 mGy, FTA: 0.923±0.167 mGy, P<0.05. There was no meaningful difference for the measured ESD of pelvis between two groups of patients (FTC: 1.256±0.315 mGy, FTA: 1.195±0.205 mGy, P=0.788. Conclusion: In pelvic radiography, positioning of testes directed to the anode of X-ray tube can decrease the receive dose.

  10. The lowest surface brightness disc galaxy known

    International Nuclear Information System (INIS)

    Davies, J.I.; Phillipps, S.; Disney, M.J.

    1988-01-01

    The discovery of a galaxy with a prominent bulge and a dominant extremely low surface brightness disc component is reported. The profile of this galaxy is very similar to the recently discovered giant low surface brightness galaxy Malin 1. The disc central surface brightness is found to be ∼ 26.4 Rμ, some 1.5 mag fainter than Malin 1 and thus by far the lowest yet observed. (author)

  11. Estimated of associated uncertainties of the linearity test of dose calibrators

    International Nuclear Information System (INIS)

    Sousa, Carlos H.S.; Peixoto, Jose G.P.

    2013-01-01

    Activimeters determine the activity of radioactive samples and them are validated by performance tests. This research determined the expanded uncertainties associated to the linearity test. Were used three dose calibrators and three sources of 99 Tc m for testing using recommended protocol by the IAEA, which considered the decay of radioactive samples. The expanded uncertainties evaluated were not correlated with each other and their analysis considered a rectangular probability distribution. The results are also presented in graphical form by the function of normalized activity measured in terms of conventional true value. (author)

  12. Effects of prenatal exposure to low-dose β radiation from tritiated water on the neutrobehavior of mice

    International Nuclear Information System (INIS)

    Wang Bing; Zhou Xiangyan.

    1995-01-01

    Pregnant adult C57BL/6J mice, randomly assigned to 1 of 4 groups, 3 of them were irradiated with β-rays from tritiated water (HTO) by a single intraperitoneal injection on the 12.5th day of gestation. Their offspring received cumulative doses of 0, 5, 10 or 30 cGy in utero. Male pups were trained and examined using a set of behavioral tests that included avoidance acquisition and avoidance maintenance, open field test, hole-board dipping, a water maze, and a food labyrinth. Results were found for most parameters in the 10 and 30 cGy groups that differed significantly from results for the controls, indicating that the behavioral teratogenic effect of prenatal exposure to chronic β-ray radiation from HTO may be greater than the same dose of acute X- or γ-irradiation and that 10 cGy may be the lowest detectable dose level at which behavioral changes is detectable under the conditions used in this experiment. (author) 56 refs

  13. Effects of prenatal exposure to low-dose {beta} radiation from tritiated water on the neutrobehavior of mice

    Energy Technology Data Exchange (ETDEWEB)

    Wang Bing [Tokyo Univ. (Japan). Faculty of Science; Zhou Xiangyan

    1995-06-01

    Pregnant adult C57BL/6J mice, randomly assigned to 1 of 4 groups, 3 of them were irradiated with {beta}-rays from tritiated water (HTO) by a single intraperitoneal injection on the 12.5th day of gestation. Their offspring received cumulative doses of 0, 5, 10 or 30 cGy in utero. Male pups were trained and examined using a set of behavioral tests that included avoidance acquisition and avoidance maintenance, open field test, hole-board dipping, a water maze, and a food labyrinth. Results were found for most parameters in the 10 and 30 cGy groups that differed significantly from results for the controls, indicating that the behavioral teratogenic effect of prenatal exposure to chronic {beta}-ray radiation from HTO may be greater than the same dose of acute X- or {gamma}-irradiation and that 10 cGy may be the lowest detectable dose level at which behavioral changes is detectable under the conditions used in this experiment. (author) 56 refs.

  14. Radiation doses to local populations near nuclear weapons test sites worldwide.

    Science.gov (United States)

    Simon, Steven L; Bouville, André

    2002-05-01

    Nuclear weapons testing was conducted in the atmosphere at numerous sites worldwide between 1946 and 1980, which resulted in exposures to local populations as a consequence of fallout of radioactive debris. The nuclear tests were conducted by five nations (United States, Soviet Union, United Kingdom, France, and China) primarily at 16 sites. The 16 testing sites, located in nine different countries on five continents (plus Oceania) contributed nearly all of the radioactive materials released to the environment by atmospheric testing; only small amounts were released at a fewother minor testing sites. The 16 sites discussed here are Nevada Test Site, USA (North American continent), Bikini and Enewetak, Marshall Islands (Oceania); Johnston Island, USA (Oceania), Christmas and Malden Island, Kiribati (Oceania); Emu Field, Maralinga, and Monte Bello Islands, Australia (Australian continent); Mururoa and Fangataufa, French Polynesia (Oceania), Reggane, Algeria (Africa), Novaya Zemlya and Kapustin Yar, Russia (Europe), Semipalatinsk, Kazakhstan (Asia), and Lop Nor, China (Asia). There were large differences in the numbers of tests conducted at each location and in the total explosive yields. Those factors, as well as differences in population density, lifestyle, environment, and climate at each site, led to large differences in the doses received by local populations. In general, the tests conducted earliest led to the highest individual and population exposures, although the amount of information available for a few of these sites is insufficient to provide any detailed evaluation of radiation exposures. The most comprehensive information for any site is for the Nevada Test Site. The disparities in available information add difficulty to determining the radiation exposures of local populations at each site. It is the goal of this paper to summarize the available information on external and internal doses received by the public living in the regions near each of the

  15. Evaluation of patient dose during computed tomography angiography

    International Nuclear Information System (INIS)

    Dafalla, Elamam Yagoob Taha

    2015-10-01

    Computed tomography (CT), is an x-ray procedure that generates high quality cross sectional images of the body, and by comparison to other radiological diagnosis, CT is responsible for higher doses to patients. The evaluation of patient dose from computed tomography for pulmonary examinations the CT is responsible for higher doses to patients. The radiation dose was measured in three hospitals in Khartoum State during March 2015-October 2015 using different CT modalities. The radiation dose was higher at Alzytouna hospital than Daralelaj hospital and Alatebaa hospital was lowest. In this study, the mean effective dose for first hospital was 23.83±3.93 mSv and the mean effective dose for second hospital was 8.94±1.64 mSv and the mean effective dose for third hospital was 2.96±0.79. (author)

  16. New aspects in distribution of population dose loads in Semipalatinsk Nuclear Test Site region

    International Nuclear Information System (INIS)

    Hill, P.; Pivovarov, S.; Rukhin, A.; Seredavina, T.; Sushkova, N.

    2008-01-01

    Full text: The question on dose loads of Semipalatinsk Nuclear Test Site (SNTS) region population is not fully solved till now. There is rather different estimations of doses, received by people of nearest to SNTS settlements. It may be explain by absence of individual dosimeters during and after nuclear weapon tests and also many various ways of radiation exposure receiving. During last some years we have done a people dose loads estimations by Electron Paramagnetic Resonance (EPR) tooth enamel dosimetry method - one of the best and reliable for retrospective dosimetry. It was studied tooth enamel people from settlements Dolon, Bodene, Cheremushki, Mostik, which was irradiated mainly by the first atomic explosion 1949, settlement Sarjal, irradiated by the first thermonuclear explosion in 1953, and control settlement Maysk, which is sited close to SNTS, but there was no any radioactive traces due to east wind. The results display a not expected rather surprising picture: in all settlements, including control one Maysk, the dose loads distribution was rather similar, it has ex fast bimodal form with rather high doses in the second one. The possible reasons of such situation is discussed. The results obtained is compared with last estimations of Semipalatinsk region dose loads of population, which were specially attentively discussed at International Symposiums in Hiroshima (Japan, 2005) and Bethesda (MD, USA, 2006). (author)

  17. The effect of chronic corticosterone on fear learning and memory depends on dose and the testing protocol.

    Science.gov (United States)

    Marks, W N; Fenton, E Y; Guskjolen, A J; Kalynchuk, L E

    2015-03-19

    Chronic exposure to the stress hormone corticosterone (CORT) is known to alter plasticity within hippocampal and amygdalar circuits that mediate fear learning and memory. The purpose of this experiment was to clarify the effects of chronic CORT on Pavlovian fear conditioning, which is dependent on intact hippocampal and amygdalar activity. In particular, we assessed whether the effect of chronic CORT on fear learning and memory is influenced by two factors-the dose of CORT and the order in which rats are tested for freezing to context versus tone cues. Male Long-Evans rats received low-dose CORT (5mg/kg), high-dose CORT (40mg/kg), or vehicle injections once daily for 21days. On day 22, the rats were trained in a fear-conditioning paradigm. On days 23 and 24, the rats were tested for the retrieval of fear memories to context and tone cues in a counterbalanced way-half the rats received context testing on day 23 and then tone testing on day 24 and half the rats received tone testing on day 23 followed by context testing on day 24. Our results revealed dose-dependent effects of CORT on memory retrieval: Rats injected with high-dose CORT froze significantly more than control rats to both context and tone cues regardless of what testing day these cues were presented. However, rats injected with low-dose CORT froze significantly more than control rats to tone cues only. We also found an order effect in that the effects of CORT on freezing were greater on the second day of testing, regardless of whether that testing was to context or tones cues. This order effect may be due to a lack of extinction in the CORT rats. Overall, these results suggest a relationship between stress intensity and testing conditions that should be taken into account when assessing the effect of stress on fear memories. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  18. Quality Assurance Testing of Version 1.3 of U.S. EPA Benchmark Dose Software (Presentation)

    Science.gov (United States)

    EPA benchmark dose software (BMDS) issued to evaluate chemical dose-response data in support of Agency risk assessments, and must therefore be dependable. Quality assurance testing methods developed for BMDS were designed to assess model dependability with respect to curve-fitt...

  19. Assessment of eight HPV vaccination programs implemented in lowest income countries

    OpenAIRE

    Ladner, Joël; Besson, Marie-Hélène; Hampshire, Rachel; Tapert, Lisa; Chirenje, Mike; Saba, Joseph

    2012-01-01

    Abstract Background Cervix cancer, preventable, continues to be the third most common cancer in women worldwide, especially in lowest income countries. Prophylactic HPV vaccination should help to reduce the morbidity and mortality associated with cervical cancer. The purpose of the study was to describe the results of and key concerns in eight HPV vaccination programs conducted in seven lowest income countries through the Gardasil Access Program (GAP). Methods The GAP provides free HPV vaccin...

  20. TestDose: A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, Marie-Paule, E-mail: marie-paule.garcia@univ-brest.fr; Villoing, Daphnée [UMR 1037 INSERM/UPS, CRCT, 133 Route de Narbonne, 31062 Toulouse (France); McKay, Erin [St George Hospital, Gray Street, Kogarah, New South Wales 2217 (Australia); Ferrer, Ludovic [ICO René Gauducheau, Boulevard Jacques Monod, St Herblain 44805 (France); Cremonesi, Marta; Botta, Francesca; Ferrari, Mahila [European Institute of Oncology, Via Ripamonti 435, Milano 20141 (Italy); Bardiès, Manuel [UMR 1037 INSERM/UPS, CRCT, 133 Route de Narbonne, Toulouse 31062 (France)

    2015-12-15

    Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest.com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user’s imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan™ therapeutical treatment was implemented using the 4D XCAT model. Whole-body “step and shoot” acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan™ kinetics, a dosimetry

  1. Pricing strategies for combination pediatric vaccines based on the lowest overall cost formulary.

    Science.gov (United States)

    Behzad, Banafsheh; Jacobson, Sheldon H; Sewell, Edward C

    2012-10-01

    This paper analyzes pricing strategies for US pediatric combination vaccines by comparing the lowest overall cost formularies (i.e., formularies that have the lowest overall cost). Three pharmaceutical companies compete pairwise over the sale of monovalent and combination vaccines. Particular emphasis is placed on examining the price of Sanofi Pasteur's DTaP-IPV/HIb under different conditions. The main contribution of the paper is to provide the lowest overall cost formularies for different prices of DTaP-IPV/HIb and other Sanofi Pasteur vaccines. The resulting analysis shows that DTaP-IPV/HIb could have been more competitively priced compared with the combination vaccine DTaP-HepB-IPV, for federal contract prices in 2009, 2010 and 2011. This study also proposes the lowest overall cost formularies when shortages of monovalent vaccines occur.

  2. The lowest Landau level in QCD

    Directory of Open Access Journals (Sweden)

    Bruckmann Falk

    2017-01-01

    Full Text Available The thermodynamics of Quantum Chromodynamics (QCD in external (electro-magnetic fields shows some unexpected features like inverse magnetic catalysis, which have been revealed mainly through lattice studies. Many effective descriptions, on the other hand, use Landau levels or approximate the system by just the lowest Landau level (LLL. Analyzing lattice configurations we ask whether such a picture is justified. We find the LLL to be separated from the rest by a spectral gap in the two-dimensional Dirac operator and analyze the corresponding LLL signature in four dimensions. We determine to what extent the quark condensate is LLL dominated at strong magnetic fields.

  3. Estimation of average glandular dose depending on the thickness of the breast

    International Nuclear Information System (INIS)

    Real, Jessica V.; Luz, Renata M. da; Fröhlich, Bruna D.; Pertile, Alessandra S.; Silva, Ana Maria Marques da

    2014-01-01

    Breast cancer is the most common type of cancer in women worldwide. Mammography is, to date, the most efficient method for detecting an abnormality in the patient's breast. It is a technique of imaging diagnostic that requires special care because radiographs without adequate quality may lead to a false diagnosis and lead to the need for a repeat examination, increasing the dose of radiation in the patient. This study aimed to evaluate the average glandular dose (AGD), depending on the breast thickness in patients undergoing routine tests, with a digital computer radiography processing system. Analyzed 30 exhibitions in patients aged (65 ± 12) years, in the right and left caudal skull projections, for breasts with thicknesses between 45 mm and 50 mm. The calculated value of the AGD for this track thickness was (1.600 ± 0.009) mGy. The performance of mammography quality control tests was satisfactory and the AGD values obtained for the chosen thickness range is acceptable, since the threshold achievable is 1.6 mGy and the acceptable is 2 mGy. In Brazil, it is only required the input dose calculation in skin for 45 mm breasts. However, the calculation of AGD is required for different thicknesses of the breast, to identify the best mammographic pattern aiming at better image quality at the lowest dose provided the patient

  4. Low-dose effect on blood chromosomes

    International Nuclear Information System (INIS)

    Pohl-Rueling, J.

    1992-01-01

    Linear dose response relationships of biological effects at low doses are experimentally and theoretically disputed. Structural chromosome aberration rates at doses ranging from normal background exposures up to about 30 mGy/yr in vivo and up to 50 mGy in vitro were investigated by the author and other scientists. Results are comparable and dose effect curves reveal following shapes; within the normal burden and up to 2-10 mGy/yr in vivo rates they increase sharply to about 3-6 times the lowest values; subsequent doses either from natural, occupational or accidental exposures up to about 30 mGy/yr yield either constant aberration rates, assuming a plateau, or perhaps even a decrease. In vitro experiments show comparable results up to 50 mGy. Other biological effects seem to have similar dose dependencies. The non-linearity of low-dose effects can be explained by induction of repair enzymes at certain damage to the DNA. This hypothesis is sustained experimentally and theoretically by several papers in literature. (author). 14 refs., 5 figs

  5. The feasibility of 10 keV X-ray as radiation source in total dose response radiation test

    International Nuclear Information System (INIS)

    Li Ruoyu; Li Bin; Luo Hongwei; Shi Qian

    2005-01-01

    The standard radiation source utilized in traditional total dose response radiation test is 60 Co, which is environment-threatening. X-rays, as a new radiation source, has the advantages such as safety, precise control of dose rate, strong intensity, possibility of wafer-level test or even on-line test, which greatly reduce cost for package, test and transportation. This paper discussed the feasibility of X-rays replacing 60 Co as the radiation source, based on the radiation mechanism and the effects of radiation on gate oxide. (authors)

  6. Patch test concentrations (doses in mg/cm(2) ) for the 12 non-mix fragrance substances regulated by European legislation

    DEFF Research Database (Denmark)

    Bruze, Magnus; Svedman, Cecilia; Andersen, Klaus Ejner

    2012-01-01

    Background. According to EU legislation, 26 fragrance substance allergens must be labelled on cosmetic products. For 12 of them, the optimal patch test concentration/dose has not been evaluated. Objectives. To establish the optimal patch test doses in mg/cm(2) for the 12 fragrance substances......, it is recommended that half of the maximum patch test dose (mg/cm(2) ) be used for aimed and screening patch testing....... that are not included in fragrance mix I or II in the European baseline patch test series. Materials and Methods. Patch testing with the 12 fragrance substances was performed in a stepwise manner encompassing up to five rounds in at least 100 dermatitis patients for each round. Before patch testing, an individual...

  7. A dose assessment for a U.S. nuclear test site -- Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Bogen, K.T.; Conrado, C.L.

    1993-07-01

    On March 1, 1954, a nuclear weapon test, code-named BRAVO, conducted at Bikini Atoll in the northern Marshall Islands contaminated the major residence island. Here the authors provide a radiological dose assessment for the main residence island, Bikini, using extensive radionuclide concentration data derived from analysis of food crops, ground water, cistern water, fish and other marine species, animals, air, and soil collected at Bikini Island. The unique composition of coral soil greatly alters the relative contribution of cesium-137 and strontium-90 to the total estimated dose relative to expectations based on North American and European soils. Cesium-137 produces 96% of the estimated dose for returning residents, mostly through uptake from the soil to terrestrial food crops but also from external gamma exposure. The estimated maximum annual effective dose is 4.4 mSv y -1 when imported foods, which are now an established part of the diet, are available. The 30-, 50-, and 70-y integral effective doses are 10 cSv, 14 cSv, and 16 cSv, respectively. An analysis of interindividual variability in 0- to 30-y expected integral dose indicates that 95% of Bikini residents would have expected doses within a factor of 3.4 above and 4.8 below the population-average value. A corresponding uncertainty analysis showed that after about 5 y of residence, the 95% confidence limits on population-average dose would be ±35% of its expected value. The authors have evaluated various countermeasures to reduce 137 Cs in food crops. Treatment with potassium reduces the uptake of 137 Cs into food crops, and therefore the ingestion dose, to less than 10% of pretreatment levels and has essentially no negative environmental consequences

  8. Direct dosing of preweaning rodents in toxicity testing and research: deliberations of an ILSI RSI Expert Working Group.

    Science.gov (United States)

    Moser, Virginia C; Walls, Isabel; Zoetis, Tracey

    2005-01-01

    Laboratory animal studies designed to assess the effects of exposure of a test substance during postnatal development are commonly utilized in basic research and to evaluate potential hazard to children for chemical and pharmaceutical regulation. Direct dosing, defined here as the administration of a test substance directly to a preweaning mammal, has been identified as a useful tool that can be used in the conduct of such studies for regulatory purposes. The International Life Sciences Institute Risk Science Institute (ILSI RSI) convened an Expert Working Group to develop guidance on the design and implementation of direct dosing regulatory studies on preweaning mammals, which was published as an ILSI monograph in 2003 (Zoetis and Walls, Principles and Practices for Direct Dosing of Pre-Weaning Mammals in Toxicity Testing and Research, Washington, DC: ILSI Press, 2003). A summary of the Working Group conclusions regarding direct dosing studies with laboratory rodents are presented here, although the ILSI monograph also includes rabbits, canines, swine and nonhuman primates. Issues to be considered when designing the protocol include selection of the test species, the route of administration, dose levels, and the timing of dosing. Knowledge of the maturational status of the test species and information on critical windows of development are important in creating a valid study design. Most common routes of administration (e.g., oral, inhalation, injection) are possible with typical laboratory species; however, adjustments may be necessary due to practical considerations. Information on the pharmacokinetic profile in young animals versus adults and in the test species versus humans is very useful for determining dosing parameters. The conduct of the study and the interpretation of the data will be improved by an understanding of confounding factors as well as statistical and biological issues specific for postnatal studies. Ultimately, the success of the study will

  9. Atomic force microscopy and mechanical testing of bovine pericardium irradiated to radiotherapy doses

    International Nuclear Information System (INIS)

    Daar, Eman; Kaabar, W.; Woods, E.; Lei, C.; Nisbet, A.; Bradley, D.A.

    2014-01-01

    Within the context of radiotherapy our work investigates the feasibility of identifying changes in structural and biomechanical properties of pericardium resulting from exposure to penetrating photon irradiation. Collagen fibres extracted from bovine pericardium were chosen as a model of pericardium extracellular matrix as these form the main fibrous component of the medium. Tests of mechanical properties, controlled by the various structural elements of the tissues, were performed on frontal pericardium, including uni-axial tests and atomic force microscopy (AFM). While the irradiated collagen fibres showed no significant change in D-band spacing up to doses of 80 Gy, the fibre width was found to increase by 34±9% at 80 Gy when compared with that for un-irradiated samples. - Highlights: • Methods for identifying changes in tissue biophysical properties following photon irradiation. • Tests made using collagen fibres extracted from bovine pericardium. • Sensitivity of uni-axial tests and atomic force microscopy (AFM) investigated. • Radiotherapy doses investigated up to 80 Gy, delivered by 6 MV photons

  10. Indoor gamma dose measurements in Gudalore (India) using TLD

    International Nuclear Information System (INIS)

    Sivakumar, R.; Selvasekarapandian, S.; Mugunthamanikandan, N.; Raghunath, V.M.

    2002-01-01

    Indoor gamma radiation dose rates were measured inside residential buildings in Gudalore using a CaSO 4 : Dy thermoluminescent dosimeter for 1 year . Significant seasonal variations are observed. The highest dose rate is observed during summer and the lowest in winter. The dose rates observed are between 77.9 and 229.3 nGy h -1 and may be attributed to the type of building materials used in the dwellings monitored. The calculated mean annual effective dose equivalent rates range between 477.6 μSv y -1 , for the inhabitants of mud houses to 1406.3 μSv y -1 , for those living in terrace houses made of cement and brick

  11. Dose effect relationships in cervical and thoracic radiation myelopathies

    International Nuclear Information System (INIS)

    Holdorff, B.

    1980-01-01

    The course and prognosis of radiation myelopathies are determined by 3 factors: the segmental (vertical) location of the lesion, the extent of the transverse syndrome (complete or incomplete) and the radiation dose. The median spinal dose in cervical radiation myelopathies with fatal outcome was higher than in survivals with an incomplete transverse syndrome. In thoracic radiation myelopathies a dose difference between complete and incomplete transverse syndromes could be found as well. Incomplete transverse syndromes as submaximum radiation injuries are more suitable for the determination of the spinal tolerance dose than complete transverse syndromes. The lowest threshold could be stated for cases following high-volume irradiation of the lymphatic system. (Auth.)

  12. Iodine-129 Dose in LLW Disposal Facility Performance Assessments

    International Nuclear Information System (INIS)

    Wilhite, E.L.

    1999-01-01

    Iodine-129 has the lowest Performance Assessment derived inventory limit in SRS disposal facilities. Because iodine is concentrated in the body to one organ, the thyroid, it has been thought that dilution with stable iodine would reduce the dose effects of 129I.Examination of the dose model used to establish the Dose conversion factor for 129I shows that, at the levels considered in performance assessments of low-level waste disposal facilities, the calculated 129I dose already accounts for ingestion of stable iodine. At higher than normal iodine ingestion rates, the uptake of iodine by the thyroid itself decrease, which effectively cancels out the isotopic dilution effect

  13. Radiation dose reduction for CT assessment of urolithiasis using iterative reconstruction. A prospective intra-individual study

    Energy Technology Data Exchange (ETDEWEB)

    Harder, Annemarie M. den; Willemink, Martin J.; Wessels, Frank J.; Schilham, Arnold M.R.; Leiner, Tim; Jong, Pim A. de [Utrecht University Medical Center, Department of Radiology, Utrecht (Netherlands); Doormaal, Pieter J. van; Budde, Ricardo P.J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Lock, M.T.W.T. [University Medical Center, Department of Urology, Utrecht (Netherlands)

    2018-01-15

    To assess the performance of hybrid (HIR) and model-based iterative reconstruction (MIR) in patients with urolithiasis at reduced-dose computed tomography (CT). Twenty patients scheduled for unenhanced abdominal CT for follow-up of urolithiasis were prospectively included. Routine dose acquisition was followed by three low-dose acquisitions at 40%, 60% and 80% reduced doses. All images were reconstructed with filtered back projection (FBP), HIR and MIR. Urolithiasis detection rates, gall bladder, appendix and rectosigmoid evaluation and overall subjective image quality were evaluated by two observers. 74 stones were present in 17 patients. Half the stones were not detected on FBP at the lowest dose level, but this improved with MIR to a sensitivity of 100%. HIR resulted in a slight decrease in sensitivity at the lowest dose to 72%, but outperformed FBP. Evaluation of other structures with HIR at 40% and with MIR at 60% dose reductions was comparable to FBP at routine dose, but 80% dose reduction resulted in non-evaluable images. CT radiation dose for urolithiasis detection can be safely reduced by 40 (HIR)-60 (MIR) % without affecting assessment of urolithiasis, possible extra-urinary tract pathology or overall image quality. (orig.)

  14. Dose calibrator linearity test: {sup 99m}Tc versus {sup 18}F radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Willegaignon, Jose; Coura-Filho, George Barberio; Garcez, Alexandre Teles, E-mail: willegaignon@hotmail.com [Instituto do Cancer do Estado de Sao Paulo Octavio Frias de Oliveira (ICESP), Sao Paulo, SP (Brazil); Sapienza, Marcelo Tatit; Buchpiguel, Carlos Alberto [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Fac. de Medicina; Alves, Carlos Eduardo Gonzalez Ribeiro; Cardona, Marissa Anabel Rivera; Gutterres, Ricardo Fraga [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2015-01-15

    Objective: the present study was aimed at evaluating the viability of replacing {sup 18}F with {sup 99m}Tc in dose calibrator linearity testing. Materials and methods: the test was performed with sources of {sup 99m}Tc (62 GBq) and {sup 18}F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical {sup 99m}Tc and {sup 18}F sources activities were calculated and subsequently compared. Results: mean deviations between experimental and theoretical {sup 99m}Tc and {sup 18}F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the {sup 99m}Tc source as measured with the equipment precalibrated to measure {sup 99m}Tc and {sup 18}F was 3.42 (± 0.06), and for the {sup 18}F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: the results of the linearity test using {sup 99m}Tc were compatible with those obtained with the {sup 18}F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in {sup 18}F acquisition suggest {sup 99m}Tc as the element of choice to perform dose calibrator linearity tests in centers that use {sup 18}F, without any detriment to the procedure as well as to the quality of the nuclear medicine service. (author)

  15. Supplementary comparison CCRI(I)-S2 of standards for absorbed dose to water in 60Co gamma radiation at radiation processing dose levels

    DEFF Research Database (Denmark)

    Burns, D. T.; Allisy-Roberts, P. J.; Desrosiers, M. F.

    2011-01-01

    Eight national standards for absorbed dose to water in 60Co gamma radiation at the dose levels used in radiation processing have been compared over the range from 1 kGy to 30 kGy using the alanine dosimeters of the NIST and the NPL as the transfer dosimeters. The comparison was organized...... by the Bureau International des Poids et Mesures, who also participated at the lowest dose level using their radiotherapy-level standard for the same quantity. The national standards are in general agreement within the standard uncertainties, which are in the range from 1 to 2 parts in 102. Evidence of a dose...

  16. Health effect of low dose/low dose rate radiation

    International Nuclear Information System (INIS)

    Kodama, Seiji

    2012-01-01

    The clarified and non-clarified scientific knowledge is discussed to consider the cause of confusion of explanation of the title subject. The low dose is defined roughly lower than 200 mGy and low dose rate, 0.05 mGy/min. The health effect is evaluated from 2 aspects of clinical symptom/radiation hazard protection. In the clinical aspect, the effect is classified in physical (early and late) and genetic ones, and is classified in stochastic (no threshold value, TV) and deterministic (with TV) ones from the radioprotection aspect. Although the absence of TV in the carcinogenic and genetic effects has not been proved, ICRP employs the stochastic standpoint from the safety aspect for radioprotection. The lowest human TV known now is 100 mGy, meaning that human deterministic effect would not be generated below this dose. Genetic deterministic effect can be observable only in animal experiments. These facts suggest that the practical risk of exposure to <100 mGy in human is the carcinogenesis. The relationship between carcinogenic risk in A-bomb survivors and their exposed dose are found fitted to the linear no TV model, but the epidemiologic data, because of restriction of subject number analyzed, do not always mean that the model is applicable even below the dose <100 mGy. This would be one of confusing causes in explanation: no carcinogenic risk at <100 mGy or risk linear to dose even at <100 mGy, neither of which is scientifically conclusive at present. Also mentioned is the scarce risk of cancer in residents living in the high background radiation regions in the world in comparison with that in the A-bomb survivors exposed to the chronic or acute low dose/dose rate. Molecular events are explained for the low-dose radiation-induced DNA damage and its repair, gene mutation and chromosome aberration, hypothesis of carcinogenesis by mutation, and non-targeting effect of radiation (bystander effect and gene instability). Further researches to elucidate the low dose

  17. Different concentrations and volumes of p-phenylenediamine in pet. (equivalent doses) are associated with similar patch test outcomes

    DEFF Research Database (Denmark)

    Andersen, Flemming; Hamann, Carsten R; Andersen, Klaus E

    2018-01-01

    BACKGROUND: Concern about causing active sensitization when patch testing is performed with p-phenylenediamine (PPD) 1% pet. has led to a recommendation to use PPD 0.3% pet. as a potentially safer preparation. However, the dose per area of allergen delivered, and hence the risk of active...... sensitization, depend on the amount dispensed into the patch test chamber, which can vary widely. OBJECTIVE: To evaluate whether patch testing with equivalent doses of different concentrations of PPD in pet. is associated with similar outcomes. METHODS: Seventeen known PPD-sensitive subjects were patch tested...... with different volumes and concentrations of PPD in pet. that deliver the same allergen dose per unit area (6 mg of PPD 1% pet. and 20 mg of PPD 0.3% pet. in Finn Chambers®, both equivalent to ∼ 0.09 mg/cm2 ). RESULTS: Eleven patients (65%) had positive reactions to both doses; 4 patients (24%) had negative...

  18. Reduction of patient doses in X-ray diagnosis using quality control tests on image and equipment

    International Nuclear Information System (INIS)

    Milu, C.; Tomulescu, V.; Sorescu, Anca; Vladareanu, M.; Olteanu, B.; Enachescu, B.; Zaharia, N.; Lesaru, M.

    1997-01-01

    In the frame of a research program under the contract with the International Atomic Energy Agency (IAEA), several patient dose measurements were performed using thermoluminescent dosemeters (TLDs) before and after application of Quality Control tests and patient dose reduction methods. The paper evidenced the practical influence factors (like the need of use of high voltage technique) and possibilities for dose reduction keeping the image quality. (authors)

  19. 48 CFR 47.306-2 - Lowest overall transportation costs.

    Science.gov (United States)

    2010-10-01

    ... transportation costs. 47.306-2 Section 47.306-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT TRANSPORTATION Transportation in Supply Contracts 47.306-2 Lowest overall transportation costs. (a) For the evaluation of offers, the transportation officer shall give to the contracting...

  20. Measurements of integrated components' parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests

    International Nuclear Information System (INIS)

    Fuan, J.

    1991-01-01

    This paper describes the methodology used for the irradiation of the integrated components and the measurements of their parameters, using Quality Insurance of dosimetry: - Measurement of the integrated dose using the competences of the Laboratoire Central des Industries Electriques (LCIE): - Measurement of irradiation dose versus source/component distance, using a calibrated equipment. - Use of ALANINE dosimeters, placed on the support of the irradiated components. - Assembly and polarization of components during the irradiations. Selection of the irradiator. - Measurement of the irradiated components's parameters, using the competences of the societies: - GenRad: GR130 tests equipement placed in the DEIN/SIR-CEN SACLAY. - Laboratoire Central des Industries Electriques (LCIE): GR125 tests equipment and this associated programmes test [fr

  1. Correlation between Colon Transit Time Test Value and Initial Maintenance Dose of Laxative in Children with Chronic Functional Constipation

    Science.gov (United States)

    Kim, Mock Ryeon; Park, Hye Won; Son, Jae Sung; Lee, Ran

    2016-01-01

    Purpose To evaluate the correlation between colon transit time (CTT) test value and initial maintenance dose of polyethylene glycol (PEG) 4000 or lactulose. Methods Of 415 children with chronic functional constipation, 190 were enrolled based on exclusion criteria using the CTT test, defecation diary, and clinical chart. The CTT test was performed with prior disimpaction. The laxative dose for maintenance was determined on the basis of the defecation diary and clinical chart. The Shapiro-Wilk test and Pearson's and Spearman's correlations were used for statistical analysis. Results The overall group median value and interquartile range of the CTT test was 43.8 (31.8) hours. The average PEG 4000 dose for maintenance in the overall group was 0.68±0.18 g/kg/d; according to age, the dose was 0.73±0.16 g/kg/d (encopresis, abnormal CTT test subtype) for either laxative. Even in the largest group (overall, n=109, younger than 8 years and on PEG 4000), the correlation was weak (Pearson's correlation coefficient [R]=0.268, p=0.005). Within the abnormal transit group, subgroup (n=73, younger than 8 years and on PEG 4000) correlation was weak (R=0.267, p=0.022). Conclusion CTT test value cannot predict the initial maintenance dose of PEG 4000 or lactulose with linear correlation. PMID:27738600

  2. Recreating the seawater mixture composition of HOCs in toxicity tests with Artemia franciscana by passive dosing

    Energy Technology Data Exchange (ETDEWEB)

    Rojo-Nieto, E., E-mail: elisa.rojo@uca.es [Andalusian Centre of Marine Science and Technology (CACYTMAR), Department of Environmental Technologies, University of Cadiz, 11510 Puerto Real (Spain); Smith, K.E.C. [Department of Environmental Science, Aarhus University, DK-4000 Roskilde (Denmark); Perales, J.A. [Andalusian Centre of Marine Science and Technology (CACYTMAR), Department of Environmental Technologies, University of Cadiz, 11510 Puerto Real (Spain); Mayer, P. [Department of Environmental Science, Aarhus University, DK-4000 Roskilde (Denmark)

    2012-09-15

    The toxicity testing of hydrophobic organic compounds (HOCs) in aquatic media is generally challenging, and this is even more problematic for mixtures. The hydrophobic properties of these compounds make them difficult to dissolve, and subsequently to maintain constant exposure concentrations. Evaporative and sorptive losses are highly compound-specific, which can alter not only total concentrations, but also the proportions between the compounds in the mixture. Therefore, the general aim of this study was to explore the potential of passive dosing for testing the toxicity of a PAH mixture that recreates the mixture composition found in seawater from a coastal area of Spain, the Bay of Algeciras. First, solvent spiking and passive dosing were compared for their suitability to determine the acute toxicity to Artemia franciscana nauplii of several PAHs at their respective solubility limits. Second, passive dosing was applied to recreate the seawater mixture composition of PAHs measured in a Spanish monitoring program, to test the toxicity of this mixture at different levels. HPLC analysis was used to confirm the reproducibility of the dissolved exposure concentrations for the individual PAHs and mixtures. This study shows that passive dosing has some important benefits in comparison with solvent spiking for testing HOCs in aquatic media. These include maintaining constant exposure concentrations, leading to higher reproducibility and a relative increase in toxicity. Passive dosing is also able to faithfully reproduce real mixtures of HOCs such as PAHs, in toxicity tests, reproducing both the levels and proportions of the different compounds. This provides a useful approach for studying the toxicity of environmental mixtures of HOCs, both with a view to investigating their toxicity but also for determining safety factors before such mixtures result in detrimental effects.

  3. A Performance Evaluation of a Notebook PC under a High Dose-Rate Gamma Ray Irradiation Test

    Directory of Open Access Journals (Sweden)

    Jai Wan Cho

    2014-01-01

    Full Text Available We describe the performance of a notebook PC under a high dose-rate gamma ray irradiation test. A notebook PC, which is small and light weight, is generally used as the control unit of a robot system and loaded onto the robot body. Using TEPCO’s CAMS (containment atmospheric monitoring system data, the gamma ray dose rate before and after a hydrogen explosion in reactor units 1–3 of the Fukushima nuclear power plant was more than 150 Gy/h. To use a notebook PC as the control unit of a robot system entering a reactor building to mitigate the severe accident situation of a nuclear power plant, the performance of the notebook PC under such intense gamma-irradiation fields should be evaluated. Under a similar dose-rate (150 Gy/h gamma ray environment, the performances of different notebook PCs were evaluated. In addition, a simple method for a performance evaluation of a notebook PC under a high dose-rate gamma ray irradiation test is proposed. Three notebook PCs were tested to verify the method proposed in this paper.

  4. Evaluation of automatic exposure control system chamber for the dose optimization when examining pelvic in digital radiography.

    Science.gov (United States)

    Kim, Sung-Chul; Lee, Hae-Kag; Lee, Yang-Sub; Cho, Jae-Hwan

    2015-01-01

    We found a way to optimize the image quality and reduce the exposure dose of patients through the proper activity combination of the automatic exposure control system chamber for the dose optimization when examining the pelvic anteroposterior side using the phantom of the human body standard model. We set 7 combinations of the chamber of automatic exposure control system. The effective dose was yielded by measuring five times for each according to the activity combination of the chamber for the dose measurement. Five radiologists with more than five years of experience evaluated the image through picture archiving and communication system using double blind test while classifying the 6 anatomical sites into 3-point level (improper, proper, perfect). When only one central chamber was activated, the effective dose was found to be the highest level, 0.287 mSv; and lowest when only the top left chamber was used, 0.165 mSv. After the subjective evaluation by five panel members on the pelvic image was completed, there was no statistically meaningful difference between the 7 chamber combinations, and all had good image quality. When testing the pelvic anteroposterior side with digital radiography, we were able to reduce the exposure dose of patients using the combination of the top right side of or the top two of the chamber.

  5. The use of TLD-700H dosemeters in the assessment of external doses at the former Semipalatinsk nuclear test site.

    Science.gov (United States)

    Hill, P; Dederichs, H; Pillath, J; Schlecht, W; Hille, R; Artemev, O; Ptitskaya, L; Akhmetov, M

    2002-01-01

    The joint projects performed since 1995 by the Jülich Research Centre in co-operation with the Kazakh National Nuclear Centre in the area of the former nuclear test site near Semipalatinsk, in eastern Kazakhstan, have assessed the current dose rate of the population at and around the test site, as well as determining retrospectively the dose rate of persons affected by the atmospheric tests. Measurements of the population by personal dosemeters depend on reliably wearing these dosemeters over prolonged periods of time, and of a sufficient dosemeter return. In the past, such measurements have been particularly successful whenever short wearing times were possible. This requires high sensitivity of the dosemeters. The suitability of the highly sensitive TLD material of the BICRON TLD 700H type for such personal dosimetry measurements was investigated. It was tested in practical field application at the Semipalatinsk nuclear test site in September 2000. Initial results are available from individual doses received by a group of geologists and a group of herdsmen at the test site. For the first time, the individual dose was measured directly in these population groups. Detection limits below 1 microSv permit informative measurements for wearing times of less than two weeks. Most individual doses did not arise significantly out of local fluctuations of natural background. A conservative assessment from the aspect of practical health physics yielded a mean personal dose of 0.55 microSv per day for the herdsmen, whereas the geologists received a mean personal dose of 0.45 microSv per day. For an annual exposure period of typically, about three months, the radiation dose received by the persons investigated, in addition to the natural radiation exposure, is thus well below the international limit value of 1 mSv x a(-1) for the population dose.

  6. The radiochromic dye film dose meter as a possible test of particle track theory

    International Nuclear Information System (INIS)

    Hansen, J.W.; Jensen, M.; Katz, R.

    1980-09-01

    The response characteristic of the thin-film radiometric dye cyanide plastic dose meter to ionizing radiation of electrons and heavy charged particles is investigated as a possible test of the particle track theory worked out by Robert Katz and coworkers. Dose response curves for low-LET radiation have been investigated and are used for a quality estimation of the response for protons and oxygen ions at 16 and 4 MeV/amu, respectively. A bleaching effect on the colouration at high doses intimates that the target cannot be interpreted lieerally, but it might still be possinle to transfer the function of the macroscopic dose response to a theoretical dose response curve in a microscopic scale for a single ion. From this relation the macroscopic dose response curve can be determined qhen the film is irradiated with heavy ions. It will be shown theoretically that for protons there is no saturation in the track core, whereas calculations for oxygen ions show a heavy saturation in the track core, which means that a part of the ions loose their energy ineffectively. We can conclude that itis possible qualitatively to predict the dose response curve for high-LET particles by means of the dose response curve for low-LET radiation. (author)

  7. Analysis and planning of dose-finding studies with active control

    International Nuclear Information System (INIS)

    Helms, Hans-Joachim

    2014-01-01

    In the clinical development of radiopharmaceuticals the dose finding plays an important role. The contribution is focused on the evaluation and planning of dose finding studies with active control. It is of primary interest to find the lowest dose that yields the same efficacy as the active control. Besides the target dose confidence intervals are of importance to describe the quality of the target dose estimation. The calculation of case numbers and the determination of the dose steps to be studied are challenging under practical conditions. The contribution covers the demonstration of the statistical model the parameter estimation and the asymptotic properties based on maximum likelihood theory, the spline-based evaluation of nonlinear dose finding studies with active control and the planning of design and number of cases.

  8. Indoor gamma dose measurements in Gudalore (India) using TLD

    Energy Technology Data Exchange (ETDEWEB)

    Sivakumar, R.; Selvasekarapandian, S. E-mail: spandian@bharathi.ernet.in; Mugunthamanikandan, N.; Raghunath, V.M

    2002-06-01

    Indoor gamma radiation dose rates were measured inside residential buildings in Gudalore using a CaSO{sub 4} : Dy thermoluminescent dosimeter for 1 year . Significant seasonal variations are observed. The highest dose rate is observed during summer and the lowest in winter. The dose rates observed are between 77.9 and 229.3 nGy h{sup -1} and may be attributed to the type of building materials used in the dwellings monitored. The calculated mean annual effective dose equivalent rates range between 477.6 {mu}Sv y{sup -1}, for the inhabitants of mud houses to 1406.3 {mu}Sv y{sup -1}, for those living in terrace houses made of cement and brick.

  9. Individual dose reconstruction among residents living in the vicinity of the Semipalatinsk nuclear test site using EPR spectroscopy of tooth enamel.

    Science.gov (United States)

    Ivannikov, A I; Zhumadilov, Zh; Gusev, B I; Miyazawa, Ch; Jiao, L; Skvortsov, V G; Stepanenko, V F; Takada, J; Hoshi, M

    2002-08-01

    Individual accumulated doses were determined by EPR spectroscopy of tooth enamel for 26 adult persons residing in territories adjacent to the Semipalatinsk Nuclear Test Site (SNTS). The absorbed dose values due to radiation from nuclear tests were obtained after subtracting the contribution of natural background radiation from the total accumulated dose. The determined dose values ranged up to 250 mGy, except for one person from Semipalatinsk city with a measured dose of 2.8 +/- 0.4 Gy. Increased dose values were determined for the individuals whose teeth were formed before 1962, the end of the atmospheric nuclear tests. These values were found to be significantly larger than those obtained for a group of younger residents of heavily exposed territories and the residents of territories not exposed to radioactive fallout. These increased dose values are consistent with those based on officially registered data for the Northeastern part of Kazakstan adjacent to SNTS, which was exposed to high levels of radioactive fallout from nuclear tests in period 1949-1962.

  10. Dependence of total dose response of bipolar linear microcircuits on applied dose rate

    International Nuclear Information System (INIS)

    McClure, S.; Will, W.; Perry, G.; Pease, R.L.

    1994-01-01

    The effect of dose rate on the total dose radiation hardness of three commercial bipolar linear microcircuits is investigated. Total dose tests of linear bipolar microcircuits show larger degradation at 0.167 rad/s than at 90 rad/s even after the high dose rate test is followed by a room temperature plus a 100 C anneal. No systematic correlation could be found for degradation at low dose rate versus high dose rate and anneal. Comparison of the low dose rate with the high dose rate anneal data indicates that MIL-STD-883, method 1019.4 is not a worst-case test method when applied to bipolar microcircuits for low dose rate space applications

  11. Comparison of dose-responses of contact allergens using the guinea pig maximization test and the local lymph node assay

    NARCIS (Netherlands)

    Och, F.M.M. van; Vandebriel, R.J.; Prinsen, M.K.; Jong, W.H. de; Slob, W.; Loveren, H. van

    2001-01-01

    The guinea pig maximization test (GPMT) has been used as a method for the prediction of skin sensitizing potential for over 30 years. Besides hazard identification, risk assessment of sensitizing chemicals requires the assessment of potency. For the determination of potency based on lowest effective

  12. Dose-dependent metabolic disposition of hydroxytyrosol and formation of mercapturates in rats.

    Science.gov (United States)

    Kotronoulas, Aristotelis; Pizarro, Nieves; Serra, Aida; Robledo, Patricia; Joglar, Jesús; Rubió, Laura; Hernaéz, Alvaro; Tormos, Carmen; Motilva, Ma José; Fitó, Montserrat; Covas, Maria-Isabel; Solà, Rosa; Farré, Magí; Saez, Guillermo; de la Torre, Rafael

    2013-11-01

    Hydroxytyrosol (HT), one of the major polyphenols present in olive oil, is known to possess a high antioxidant capacity. The aim of the present study was to investigate dose dependent (0, 1, 10 and 100 mg/kg) alterations in the metabolism of HT in rats since it has been reported that metabolites may contribute to biological effects. Special attention was paid to the activation of the semiquinone-quinone oxidative cycle and the formation of adducts with potential deleterious effects. Thus, we developed a novel analytical methodology to monitor the in vivo formation of the HT mercapturate, N-acetyl-5-S-cysteinyl-hydroxytyrosol in urine samples. Biomarkers of hepatic and renal toxicity were evaluated within the dose range tested. Following HT administration, dose-dependent effects were observed for the recovery of all the metabolites studied. At the lowest dose of 1 mg/kg, the glucuronidation pathway was the most relevant (25-30%), with lower recoveries for sulfation (14%), while at the highest dose of 100 mg/kg, sulfation was the most prevalent (75%). In addition, we report for the first time the formation of the mercapturate conjugate of HT in a dose-dependent manner. The biochemical data did not reveal significant toxic effects of HT at any of the doses studied. An increase in the GSH/GSSG ratio at the highest dose was observed indicating that the products of HT autoxidation are counteracted by glutathione, resulting in their detoxification. These results indicate that the metabolic disposition of HT is highly dependent on the dose ingested. Copyright © 2013. Published by Elsevier Ltd.

  13. Lowest-order constrained variational method for simple many-fermion systems

    International Nuclear Information System (INIS)

    Alexandrov, I.; Moszkowski, S.A.; Wong, C.W.

    1975-01-01

    The authors study the potential energy of many-fermion systems calculated by the lowest-order constrained variational (LOCV) method of Pandharipande. Two simple two-body interactions are used. For a simple hard-core potential in a dilute Fermi gas, they find that the Huang-Yang exclusion correction can be used to determine a healing distance. The result is close to the older Pandharipande prescription for the healing distance. For a hard core plus attractive exponential potential, the LOCV result agrees closely with the lowest-order separation method of Moszkowski and Scott. They find that the LOCV result has a shallow minimum as a function of the healing distance at the Moszkowski-Scott separation distance. The significance of the absence of a Brueckner dispersion correction in the LOCV result is discussed. (Auth.)

  14. Spiral CT and radiation dose

    International Nuclear Information System (INIS)

    Imhof, H.; Schibany, N.; Ba-Ssalamah, A.; Czerny, C.; Hojreh, A.; Kainberger, F.; Krestan, C.; Kudler, H.; Noebauer, I.; Nowotny, R.

    2003-01-01

    Recent studies in the USA and Europe state that computed tomography (CT) scans compromise only 3-5% of all radiological exams, but they contribute 35-45% of total radiation dose to the patient population. These studies lead to concern by several public authorities. Basis of CT-dose measurements is the computed tomography dose index (CTDI), which was established 1981. Nowadays there are several modifications of the CTDI values, which may lead to confusion. It is suggested to use the standardized CTDI-100 w. value together with the dose length product in all CT-examinations. These values should be printed on all CT-images and allows an evaluation of the individualized patient dose. Nowadays, radiologist's aim must be to work at the lowest maximal diagnostic acceptable signal to noise ratio. To decrease radiation dose radiologist should use low kV and mA, but high pitches. Newly developed CT-dose-reduction soft-wares and filters should be installed in all CT-machines. We should critically compare the average dose used for a specific examination with the reference dose used in this country and/or Europe. Greater differences should caution the radiologist. Finally, we as radiologists must check very carefully all indications and recommend alternative imaging methods. But we have also to teach our customers--patients and medical doctors who are non-radiologists--that a 'good' image is not that which show all possible information, but that which visualize 'only' the diagnostic necessary information

  15. Testing equality and interval estimation in binary responses when high dose cannot be used first under a three-period crossover design.

    Science.gov (United States)

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    When comparing two doses of a new drug with a placebo, we may consider using a crossover design subject to the condition that the high dose cannot be administered before the low dose. Under a random-effects logistic regression model, we focus our attention on dichotomous responses when the high dose cannot be used first under a three-period crossover trial. We derive asymptotic test procedures for testing equality between treatments. We further derive interval estimators to assess the magnitude of the relative treatment effects. We employ Monte Carlo simulation to evaluate the performance of these test procedures and interval estimators in a variety of situations. We use the data taken as a part of trial comparing two different doses of an analgesic with a placebo for the relief of primary dysmenorrhea to illustrate the use of the proposed test procedures and estimators.

  16. Effect of low dose X-ray irradiation on apoptosis in spermatogenic cells of mouse testes

    International Nuclear Information System (INIS)

    Liu Guangwei; Liu Shuchun; Lu Zhe; Gong Shouliang

    2003-01-01

    To study the effects of low dose radiation (LDR) with different doses of X-rays on the apoptosis in spermatogenic cells of male Kunming mouse testes. The time-effect and dose-effect of apoptosis in the different stages of spermatogenic cell cycles of mouse testis after LDR with different doses of X-rays were studied with light microscope using the methods of TdT-mediated dUTP nick end labeling (TUNEL) and HE staining. The apoptosis of spermatogenic cells induced by LDR had a remarkable regularity in cell types. When the dose was 0.025 Gy, spermatogonium apoptosis was taken as main. With the dose increase of irradiation (0.025-0.2 Gy), spermatocytes also showed an apoptotic change, but the apoptotic rate of spermatogonia was significantly higher than that of spermatocytes. Moreover, the apoptosis of spermatids and spermatozoa scarcely occurred after irradiation with low dose. The apoptosis of spermatogenic cells induced by LDR has a regular change, which provides a further experimental evidence for the mechanism study of hormesis by LDR

  17. Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method

    Energy Technology Data Exchange (ETDEWEB)

    Larson, David B. [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2014-10-15

    The principle of ALARA (dose as low as reasonably achievable) calls for dose optimization rather than dose reduction, per se. Optimization of CT radiation dose is accomplished by producing images of acceptable diagnostic image quality using the lowest dose method available. Because it is image quality that constrains the dose, CT dose optimization is primarily a problem of image quality rather than radiation dose. Therefore, the primary focus in CT radiation dose optimization should be on image quality. However, no reliable direct measure of image quality has been developed for routine clinical practice. Until such measures become available, size-specific dose estimates (SSDE) can be used as a reasonable image-quality estimate. The SSDE method of radiation dose optimization for CT abdomen and pelvis consists of plotting SSDE for a sample of examinations as a function of patient size, establishing an SSDE threshold curve based on radiologists' assessment of image quality, and modifying protocols to consistently produce doses that are slightly above the threshold SSDE curve. Challenges in operationalizing CT radiation dose optimization include data gathering and monitoring, managing the complexities of the numerous protocols, scanners and operators, and understanding the relationship of the automated tube current modulation (ATCM) parameters to image quality. Because CT manufacturers currently maintain their ATCM algorithms as secret for proprietary reasons, prospective modeling of SSDE for patient populations is not possible without reverse engineering the ATCM algorithm and, hence, optimization by this method requires a trial-and-error approach. (orig.)

  18. An updated dose assessment for a U.S. Nuclear Test Site - Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Bogen, K.T.; Conrado, C.L.

    1995-10-01

    On March 1, 1954, a nuclear weapon test, code-named BRAVO, conducted at Bikini Atoll in the northern Marshall Islands contaminated the major residence island. There has been a continuing effort since 1977 to refine dose assessments for resettlement options at Bikini Atoll. Here we provide a radiological dose assessment for the main residence island, Bikini, using extensive radionuclide concentration data derived from analysis of food crops, ground water, cistern water, fish and other marine species, animals, air, and soil collected at Bikini Island as part of our continuing research and monitoring program that began in 1975. The unique composition of coral soil greatly alters the relative contribution of cesium-137 ( 137 Cs) and strontium-90 ( 90 Sr) to the total estimated dose relative to expectations based on North American and European soils. Without counter measures, cesium-137 produces 96% of the estimated dose for returning residents, mostly through uptake from the soil to terrestrial food crops but also from external gamma exposure. The doses are calculated assuming a resettlement date of 1999. The estimated maximum annual effective dose for current island conditions is 4.0 mSv when imported foods, which are now an established part of the diet, are available. The corresponding 30-, 50-, and 70-y integral effective doses are 9.1 cSv, 13 cSv, and 15 cSv, respectively. A corresponding uncertainty analysis showed that after about 5 y of residence, the 95% confidence limits on population-average dose would be ±35% of its expected value. We have evaluated various countermeasures to reduce 137 Cs in food crops. Treatment with potassium reduces the uptake of 137 Cs into food crops, and therefore the ingestion dose, to about 5% of pretreatment levels and has essentially no negative environmental consequences

  19. A novel dose uncertainty model and its application for dose verification

    International Nuclear Information System (INIS)

    Jin Hosang; Chung Heetaek; Liu Chihray; Palta, Jatinder; Suh, Tae-Suk; Kim, Siyong

    2005-01-01

    Based on statistical approach, a novel dose uncertainty model was introduced considering both nonspatial and spatial dose deviations. Non-space-oriented uncertainty is mainly caused by dosimetric uncertainties, and space-oriented dose uncertainty is the uncertainty caused by all spatial displacements. Assuming these two parts are independent, dose difference between measurement and calculation is a linear combination of nonspatial and spatial dose uncertainties. Two assumptions were made: (1) the relative standard deviation of nonspatial dose uncertainty is inversely proportional to the dose standard deviation σ, and (2) the spatial dose uncertainty is proportional to the gradient of dose. The total dose uncertainty is a quadratic sum of the nonspatial and spatial uncertainties. The uncertainty model provides the tolerance dose bound for comparison between calculation and measurement. In the statistical uncertainty model based on a Gaussian distribution, a confidence level of 3σ theoretically confines 99.74% of measurements within the bound. By setting the confidence limit, the tolerance bound for dose comparison can be made analogous to that of existing dose comparison methods (e.g., a composite distribution analysis, a γ test, a χ evaluation, and a normalized agreement test method). However, the model considers the inherent dose uncertainty characteristics of the test points by taking into account the space-specific history of dose accumulation, while the previous methods apply a single tolerance criterion to the points, although dose uncertainty at each point is significantly different from others. Three types of one-dimensional test dose distributions (a single large field, a composite flat field made by two identical beams, and three-beam intensity-modulated fields) were made to verify the robustness of the model. For each test distribution, the dose bound predicted by the uncertainty model was compared with simulated measurements. The simulated

  20. Contract Source Selection: An Analysis of Lowest Price Technically Acceptable and Tradeoff Strategies

    Science.gov (United States)

    2016-06-15

    using- spss - statistics.php Lamoureux, J., Murrow, M., & Walls, C. (2015). Relationship of source selection methods to contract outcomes: an analysis ...Contract Source Selection: an Analysis of Lowest Price Technically Acceptable and Tradeoff Strategies 15 June 2016 LCDR Jamal M. Osman, USN...ACQUISITION RESEARCH PROGRAM SPONSORED REPORT SERIES Contract Source Selection: an Analysis of Lowest Price Technically Acceptable and Tradeoff

  1. In-home HIV testing and nevirapine dosing by traditional birth attendants in rural Zambia: a feasibility study.

    Science.gov (United States)

    Brennan, Alana T; Thea, Donald M; Semrau, Katherine; Goggin, Caitlin; Scott, Nancy; Pilingana, Portipher; Botha, Belinda; Mazimba, Arthur; Hamomba, Leoda; Seidenberg, Phil

    2014-01-01

    Access to lifesaving prevention of mother-to-child transmission (PMTCT) services is problematic in rural Zambia. The simplest intervention used in Zambia has been 2-dose nevirapine (NVP) administration in the peripartum period, a regimen of 1 NVP tablet to the mother at the onset of labor and 1 dose in the form of syrup to the newborn within 4 to 72 hours after birth. This 2-dose regimen has been shown to reduce MTCT by nearly 50%. We set out to demonstrate that in-home HIV testing and NVP dosing by traditional birth attendants (TBAs) is feasible and acceptable by women in rural Zambia. This was a pilot program using TBAs to perform rapid saliva-based HIV testing and administer single-dose NVP in tablet form to the mother at the onset of labor and syrup to the infant after birth. A total of 280 pregnant women were consented and enrolled into the program, of whom 124 (44.3%) gave birth at home with the assistance of a trained TBA. Of those, 16 (12.9%) were known to be HIV positive, and 101 of the remaining 108 (93.5%) accepted a rapid HIV test. All these women tested HIV negative. In the subset of 16 mothers who were HIV positive, 13 (81.3%) took single-dose NVP administered by a TBA between 1 and 24 hours prior to birth and 100% of exposed newborns (16 of 16) received NVP syrup within 72 hours after birth, 80% of whom were dosed in the first 24 hours of life. With the substantial shortage of human resources in public health care throughout sub-Saharan Africa, it is extremely valuable to utilize lay health care workers to help extended services beyond the level of the facility. Given the high uptake of PMTCT services we believe that TBAs with proper training and support can successfully provide country-approved PMTCT. © 2013 by the American College of Nurse-Midwives.

  2. Threshold dose to developing central nerve system of rats and mice from prenatal exposure to tritiated water

    International Nuclear Information System (INIS)

    Zhou Xiangyan; Wang Bing; Gao Weimin; Lu Huimin

    1999-01-01

    Objective: To study the threshold dose to the developing central nerve system of rats and mice from prenatal exposure to tritiated water. methods: Pregnant adult C 57 BL/6J strain mice and Wistar strain rats were irradiated with beta-rays from HTO by a single intraperitoneal injection on the 12.5 th and 13 th days of gestation. The activities of HTO were 24.09, 48.18 and 144.54 ( x 10 4 Bq/g bw), respectively. Fifty-six parameters including postnatal growth, neutro-behavior, pathology of brain, neuropeptide contents, changes of hippocampal neurons, Ca 2+ conductance of hippocampal neurons etc were used to test the teratogenic threshold dose the lowest dose was different from that of the control). Results: Of the observed 56 parameters of rats and mice 80.4% indicated that the threshold doses for prenatal HTO exposure ranged from 0.030 Gy to 0.092 Gy, and the other 19.6% showed the threshold doses from 0.093 to 0.300 Gy. Conclusions: There exists threshold dose from the low level tritiated water irradiation of the developing central nerve system

  3. Diabetogenic action of streptozotocin: relationship of dose to metabolic response

    Science.gov (United States)

    Junod, Alain; Lambert, André E.; Stauffacher, Werner; Renold, Albert E.

    1969-01-01

    The relationship between the dose of intravenously administered streptozotocin (a N-nitroso derivative of glucosamine) and the diabetogenic response has been explored by use of the following indices of diabetogenic action: serum glucose, urine volume, and glycosuria, ketonuria, serum immunoreactive insulin (IRI), and pancreatic IRI content. Diabetogenic activity could be demonstrated between the doses of 25 and 100 mg/kg, all indices used showing some degree of correlation with the dose administered. Ketonuria was only seen with the largest dose, 100 mg/kg. The most striking and precise correlation was that between the dose and the pancreatic IRI content 24 hr after administration of the drug, and it is suggested that this represents a convenient test system either for both related and unrelated beta cytotoxic compounds or for screening for modifying agents or antidiabetic substances of a novel type. Ability to produce graded depletion of pancreatic IRI storage capacity led to an analysis of the relationship between pancreatic IRI content and deranged carbohydrate metabolism. Abnormal glucose tolerance and insulin response were seen when pancreatic IRI was depleted by about one-third, while fasting hyperglycemia and gross glycosuria occurred when the depletion had reached two-thirds and three-quarters, respectively. The mild yet persistent anomaly produced by the lowest effective streptozotocin dose, 25 mg/kg, exhibits characteristics resembling the state of chemical diabetes in humans and might thus warrant further study as a possible model. Finally, the loss of the diabetogenic action of streptozotocin by pretreatment with nicotinamide was confirmed and was shown to be a function of the relative doses of nicotinamide and streptozotocin and of the interval between injections. PMID:4241908

  4. The origin of dose distributions in fluvial sediments, and the prospect of dating single grains from fluvial deposits using optically stimulated luminescence

    International Nuclear Information System (INIS)

    Olley, J.M.; Caitcheon, G.G.; Roberts, R.G.

    1999-01-01

    We examine the causes of the asymmetric distributions of dose observed from measurements of the optically stimulated luminescence emitted by small aliquots of fluvial quartz, and deduce that the asymmetry arises as a result of samples being composed of a mix of mainly well bleached grains with grains that were effectively unbleached at the time of deposition. We demonstrate that the shapes of the dose distributions can be used to assess the likelihood that aliquots consist only of grains that were well-bleached at the time of deposition. The more asymmetric the distribution, the greater the probability that the aliquots with the lowest dose most closely represent the true burial dose. Single grains with differing doses are present in each of the samples examined, and the population with the lowest dose gives an optical age consistent with the expected burial age. This result implies that the beta-dose heterogeneity in these deposits is small, and that the effects of micro-dosimetric variations on optical dating of individual grains are not significant for these samples. We demonstrate that single-grain dating of fluvial material is possible and practicable using standard Risoe optical dating equipment, and we conclude that application of a new regenerative-dose protocol to single grains of quartz, using the lowest dose population to estimate the burial dose, is the best available means of obtaining reliable luminescence ages for heterogeneously bleached fluvial sediments

  5. All Electron ab initio Investigations of the Three Lowest Lying Electronic States of the RuC Molecule

    DEFF Research Database (Denmark)

    Shim, Irene; Gingerich, K. A.

    2000-01-01

    The three lowest-lying electronic states of RuC, (1)Sigma(+), (3)Delta, and (1)Delta, have been investigated by performing all-electron ab initio multi-configuration self-consistent-field (CASSCF) and multi-reference configuration interaction (MRCI) calculations including relativistic corrections....... The electronic ground state is derived as (1)Sigma(+) with the spectroscopic constants r(e) = 1.616 Angstrom and omega(e) = 1085 cm(-1). The lowest-lying excited state, (3)Delta, has r(e) = 1.632 Angstrom, omega(e) = 1063 cm(-1), and T-e = 912 cm(-1). These results are consistent with recent spectroscopic values....... The chemical bonds in all three lowest-lying states are triple bonds composed of one sigma and two pi bonds. (C) 2000 Elsevier Science B.V. All rights reserved....

  6. Alternative methods for the median lethal dose (LD(50)) test: the up-and-down procedure for acute oral toxicity.

    Science.gov (United States)

    Rispin, Amy; Farrar, David; Margosches, Elizabeth; Gupta, Kailash; Stitzel, Katherine; Carr, Gregory; Greene, Michael; Meyer, William; McCall, Deborah

    2002-01-01

    The authors have developed an improved version of the up-and-down procedure (UDP) as one of the replacements for the traditional acute oral toxicity test formerly used by the Organisation for Economic Co-operation and Development member nations to characterize industrial chemicals, pesticides, and their mixtures. This method improves the performance of acute testing for applications that use the median lethal dose (classic LD50) test while achieving significant reductions in animal use. It uses sequential dosing, together with sophisticated computer-assisted computational methods during the execution and calculation phases of the test. Staircase design, a form of sequential test design, can be applied to acute toxicity testing with its binary experimental endpoints (yes/no outcomes). The improved UDP provides a point estimate of the LD50 and approximate confidence intervals in addition to observed toxic signs for the substance tested. It does not provide information about the dose-response curve. Computer simulation was used to test performance of the UDP without the need for additional laboratory validation.

  7. Effects of split fast neutron doses on the liver cells of albino Swiss mice

    International Nuclear Information System (INIS)

    Abdelmeguid, N.; Ramadan, A.A.; El-Khatib, A.M.

    1990-01-01

    The effect of neutron doses from a compact D-T neutron generator on the liver cells of adult male and female albino Swiss mice was investigated. Fast neutrons (14.5 MeV) were delivered to the whole body in a single dose or in two, four, six or eight equal doses separated by 3-day intervals. The lowest dose, 100 rem, was given over an exposure time of 6 hours and was then steadily raised to 912 rem over an exposure time of 48 hours. During exposure the neutron flux was controlled by the activation foil technique. The animals were killed for testing after each irradiation. Histological examination of the hepatocytes with a light microscope showed marked degenerative changes only after the longer irradiation periods (24, 36 and 48 h). Electron microscopy showed cytological (cytoplasmic and nuclear) changes in the hepatocytes after only 12 hours' irradiation. Densitometric scans of electron micrographs of control and 12 h-irradiated livers indicated that the control hepatocyte interphase nucleus contains approximately 72% heterochromatin, while the irradiated nucleus contains only 64% heterochromatin. (author). 13 figs., 1 tab., 18 refs

  8. Retinopathy after low dose irradiation for an intracranial tumor of the frontal lobe

    International Nuclear Information System (INIS)

    Elsaas, T.; Thorud, E.; Jetne, V.; Conradi, I.S.

    1988-01-01

    A 32-year-old man underwent an operation for an oligodendroglioma of the left frontal lobe. Postoperatively he was irradiated to a target dose of 54 Gy. One year later hedeveloped bilateral retinopathy quite similar to diabetic retinopathy. There were no clinical or biochemical signs of diabetes or hematological disease. The calcultated maximum dose to the retina was 11 Gy. This is to our knowledge the lowest retinal dose of ionizing radiation reported to produce retinopathy. (author)

  9. Acceptance test procedure for K basins dose reduction project clean and coat equipment

    International Nuclear Information System (INIS)

    Creed, R.F.

    1996-01-01

    This document is the Acceptance Test Procedure (ATP) for the clean and coat equipment designed by Oceaneering Hanford, Inc. under purchase order MDK-XVC-406988 for use in the 105 K East Basin. The ATP provides the guidelines and criteria to test the equipment's ability to clean and coat the concrete perimeter, divider walls, and dummy elevator pit above the existing water level. This equipment was designed and built in support of the Spent Nuclear Fuel, Dose Reduction Project. The ATP will be performed at the 305 test facility in the 300 Area at Hanford. The test results will be documented in WHC-SD-SNF-ATR-020

  10. Thyroid nodule prevalence and radiation dose from fallout near the Semipalatinsk test site in Kazakhstan

    International Nuclear Information System (INIS)

    Land, C.E.; Luckyanov, N.K.; Simon, S.L.; Zhumadilov, Z.; Gusev, B.I.; Hartshorne, M.N.; Carr, Z.A.

    2003-01-01

    Thyroid nodule prevalence was use as a biomarker for radiation-related thyroid cancer risk associated with dose from internal and external radiation sources in fallout from the Semipalatinsk Test Site (STS) in Kazakhstan. Ultrasound scans were done on the thyroid glands of 1990 current residents of 7 villages near the STS, all members of a defined study cohort established in the 1960s, and all juveniles at some time during 1949-1962. Questionnaire-guided interviews focused on residential history and childhood consumption of milk and milk products. A refined dose reconstruction algorithm, developed jointly by experts from Russia and the US, was applied to the resulting data to calculate individual estimates of thyroid dose from external and internal sources of fallout-related radiation. Individual radiation dose estimates ranged from zero to 20 Gy for total dose (0-1.7 Gy and 0-20 Gy for dose from external and internal sources, respectively). The ratio of internal to external dose generally increased with increasing distance, reflecting a shift towards smaller particle sizes at greater distances and more effective transfer of small particles through the foodchain. Dose-response analysis was focused on variation of nodule prevalence by sex, age at screening, measured thyroid volume, and reconstructed thyroid dose from external (mainly gamma-ray) and internal (mainly 131 I) radiation sources. Nodule prevalence was markedly higher among women and increased significantly with increasing age at screening and with thyroid volume. Highly significant dose responses were observed for nodule prevalence as a function of total thyroid dose and, in a separate analysis, of doses from internal and external sources as distinct independent variables; dose response was linear for total dose 131 I cf. x ray with respect to thyroid cancer as an endpoint, based on theoretical, experimental, and epidemiological data

  11. Radiation doses from dental radiography at private practioneers

    Energy Technology Data Exchange (ETDEWEB)

    Hylthen, J A

    1975-10-01

    This investigation was made in January 1975 together with a seminar group from the faculty of odontology in Stockholm. Every four private practising dentists in Stockholm and its environs were selected by haphazard to get an enquiry equipment etc. Every forty private practising dentists were then selected by haphazard to get a visit. 32 x-ray plants were investigated. The radiation doses showed a great spreading. The mean value of the radiation doses to the irradiated organs had been reduced about 5 times compared to a similar investigation, which was made in 1960. The use of long metal tubes and high-speed film gave the lowest dose values, while a short cone of bakelite and a low-speed film gave the highest dose values. Fluctuations in the dose values seemed also to depend on the technique. The reasons for this may be variations in the settings of the instruments and in the dark room technique.

  12. Rationality, irrationality and escalating behavior in lowest unique bid auctions.

    Science.gov (United States)

    Radicchi, Filippo; Baronchelli, Andrea; Amaral, Luís A N

    2012-01-01

    Information technology has revolutionized the traditional structure of markets. The removal of geographical and time constraints has fostered the growth of online auction markets, which now include millions of economic agents worldwide and annual transaction volumes in the billions of dollars. Here, we analyze bid histories of a little studied type of online auctions--lowest unique bid auctions. Similarly to what has been reported for foraging animals searching for scarce food, we find that agents adopt Lévy flight search strategies in their exploration of "bid space". The Lévy regime, which is characterized by a power-law decaying probability distribution of step lengths, holds over nearly three orders of magnitude. We develop a quantitative model for lowest unique bid online auctions that reveals that agents use nearly optimal bidding strategies. However, agents participating in these auctions do not optimize their financial gain. Indeed, as long as there are many auction participants, a rational profit optimizing agent would choose not to participate in these auction markets.

  13. Aquatic toxicity testing of liquid hydrophobic chemicals – Passive dosing exactly at the saturation limit

    DEFF Research Database (Denmark)

    Stibany, Felix; Nørgaard Schmidt, Stine; Schäffer, Andreas

    2017-01-01

    The aims of the present study were (1) to develop a passive dosing approach for aquatic toxicity testing of liquid substances with very high Kow values and (2) to apply this approach to the model substance dodecylbenzene (DDB, Log Kow = 8.65). The first step was to design a new passive dosing...... format for testing DDB exactly at its saturation limit. Silicone O-rings were saturated by direct immersion in pure liquid DDB, which resulted in swelling of >14%. These saturated O-rings were used to establish and maintain DDB exposure exactly at the saturation limit throughout 72-h algal growth...... at chemical activity of unity was higher than expected relative to a reported hydrophobicity cut-off in toxicity, but lower than expected relative to a reported chemical activity range for baseline toxicity. The present study introduces a new effective approach for toxicity testing of an important group...

  14. Reassessment of calculation of effective dose equivalent for the CRCN-CO Environmental Radiological Monitoring Program

    International Nuclear Information System (INIS)

    Carneiro, L.B.; Dourado, M.A.; Barbosa, R.C.

    2017-01-01

    To reassess the calculations of the effective dose equivalent to obtain data of dosimetry and the accomplishment of the analysis comparing the data of several techniques that record doses of radiation originating from the cosmogenic and terrestrial contributions that make up the so-called background radiation. the basic information to be obtained is the contribution of the difference between the terrestrial dose equivalents, even the lowest concentration of primordial radionuclides, and that of the dose equivalent, deduced from TLD readings. (author)

  15. Reassessment of calculation of effective dose equivalent for the CRCN-CO Environmental Radiological Monitoring Program

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, L.B.; Dourado, M.A.; Barbosa, R.C., E-mail: research.photonics@gmail.com [Centro Regional de Ciências Nucleares do Centro-Oeste (CRCN-CO/CNEN-GO), Abadia de Goiás, GO (Brazil)

    2017-07-01

    To reassess the calculations of the effective dose equivalent to obtain data of dosimetry and the accomplishment of the analysis comparing the data of several techniques that record doses of radiation originating from the cosmogenic and terrestrial contributions that make up the so-called background radiation. the basic information to be obtained is the contribution of the difference between the terrestrial dose equivalents, even the lowest concentration of primordial radionuclides, and that of the dose equivalent, deduced from TLD readings. (author)

  16. Prenatal exposure to a low fipronil dose disturbs maternal behavior and reflex development in rats.

    Science.gov (United States)

    Udo, Mariana S B; Sandini, Thaísa M; Reis, Thiago M; Bernardi, Maria Martha; Spinosa, Helenice S

    2014-01-01

    Fipronil (FPN) is a phenylpyrazole insecticide used in veterinary services and agriculture, and it is of considerable concern to public health. It inhibits the chloride channels associated with gamma-amino butyric acid (GABA) receptors in mammals and also inhibits the chloride channels associated with GABA and glutamate (Glu) receptors in insects. In this study, a commercial product containing fipronil was orally administered to pregnant Wistar rats at dose levels of 0.1, 1.0, or 10.0mg/kg/day from the sixth to twentieth day of gestation (n=10 pregnant rats/group). Its toxicity was evaluated based on maternal toxicity, reproductive quality, maternal behavior, and offspring physical as well as reflex development. All parameters observed in the observed offspring were assigned to one ink-marked couple in each litter (n=20 animals/group - 10 males and 10 females). The offspring couple represented the litter. Slight maternal toxicity presented during the second week of gestation for each fipronil dose and during the third gestational week at the highest dose due to lower chow intake. However, no effects were observed for gestational weight gain or gestation time, and the reproductive quality was not impaired, which suggests no adverse maternal effects from the doses during pregnancy. Moreover, the lowest fipronil dose compromised the active and reflexive maternal responses, but the highest dose induced a stereotyped active response without interfering in the reflexive reaction. For offspring development, no differences in physical growth parameters were observed between the groups. However, considering reflex development, our results showed that negative geotaxis reflex development was delayed in the offspring at the lowest fipronil dose, and palmar grasp was lost earlier at the lowest and intermediate fipronil doses. These results suggest that the alterations observed herein may be due to either the GABAergic system or endocrine disruption, considering that fipronil

  17. Annual absorbed dose rate at the surface of 38 hot and mineral springs in Iran

    Energy Technology Data Exchange (ETDEWEB)

    Bahreyni Toosi, M.; Orougi, M.H.; Sadeghzadeh, A.; Aghamir, A.; Jomehzadeh, A.; Zare, H. [Mashhad Univ. of Medical Sciences, Medical Physics Dep., Faculty of Medicine (Iran, Islamic Republic of)

    2006-07-01

    Full text of publication follows: Measurement of background radiation is very important from different points of view especially to human health. In some cases exposure rate near hot and mineral springs are higher than those of normal areas. The high background radiation of hot and mineral springs is primarily due to the presence of very high amounts of Ra 226 and its decay products. In this research, environmental gamma radiation of hot and mineral springs in Khorasan, Mazandaran and Sareeyn town in Ardabil province have been measured. Equipment used in this work included: a survey meter (R.D.S. -110), a tripod and an aluminium frame to hold the survey meter horizontally.R.D.S. -110 is a microprocessor controlled detector. This survey meter has been designed for monitoring X and rays and radiation. Measurements were carried out at one meter above water level in the vicinity of hot and mineral springs. Dose rates were recorded for one hour. The average of all recorded dose rates over one hour period was taken as the exposure rate for each station. The results indicate that in Khorasan province the highest and lowest annual absorbed dose rates were equal to 10.80 mSv/y at Shanigarmab and 0.52 mSv/y at Nasradin source respectively. In Mazandaran province maximum and minimum exposure rates equal to 54.4 and 0.53 mSv/y were obtained at the surface of Talleshmahalleh and Ghormerz sources. Exposure rates at the vicinity of Sarein sources were not very different and ranged from 1.39 to 1.59 mSv/y. The results indicate that in Khorasan province Shahingarmab hot spring has the highest annual absorbed dose rate (10.80 mSv/y) and Nasraddin in Sarbisheh has the lowest level of radiation (0.62 mSv/y). In Mazandaran province Taleshmahalleh hot mineral spring has the highest annual absorbed dose rate (54.41 mSv/y) and Ghormerz mineral spring has the lowest radiation level (0.53 mSv/y). Also in Sareeyn (in Ardabil province) Abechashm source has the highest annual absorbed dose

  18. Study on a 4-Week Recovery Test of Sweet Bee Venom after a 13-Week, Repeated, Intramuscular Dose Toxicity Test in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Chungsan Lim

    2014-06-01

    Full Text Available Objectives:This study was performed to check for reversibility in the changes induced by a 13-week, repeated, dose toxicity test of Sweet Bee Venom (SBV in Sprague-Dawley (SD rats. Methods:Fifteen male and 15 female SD rats were treated with 0.28 mg/kg of SBV (high-dosage group and the same numbers of male and female SD rats were treated with 0.2 mL/kg of normal saline (control group for 13 weeks. We selected five male and five female SD rats from the high-dosage group and the same numbers of male and female SD rats from the control group, and we observed these rats for four weeks. We conducted body-weight measurements, ophthalmic examinations, urinalyses and hematology, biochemistry, histology tests. Results:(1 Hyperemia and movement disorder were observed in the 13-week, repeated, dose toxicity test, but these symptoms were not observed during the recovery period. (2 The rats in the high-dose group showed no significant changes in weight compared to the control group. (3 No significant differences in the ophthalmic parameters, urine analyses, complete blood cell counts (CBCs, and biochemistry were observed among the recovery groups. (4 No changes in organ weights were observed during the recovery period. (5 Histological examination of the thigh muscle indicated cell infiltration, inflammation, degeneration, necrosis of muscle fiber, and fibrosis during the treatment period, but these changes were not observed during the recovery period. The fatty liver change that was observed during the toxicity test was not observed during the recovery period. No other organ abnormalities were observed. Conclusion:The changes that occurred during the 13-week, repeated, dose toxicity test are reversible, and SBV can be safely used as a treatment modality.

  19. The origin of dose distributions in fluvial sediments, and the prospect of dating single grains from fluvial deposits using optically stimulated luminescence

    CERN Document Server

    Olley, J M; Roberts, R G

    1999-01-01

    We examine the causes of the asymmetric distributions of dose observed from measurements of the optically stimulated luminescence emitted by small aliquots of fluvial quartz, and deduce that the asymmetry arises as a result of samples being composed of a mix of mainly well bleached grains with grains that were effectively unbleached at the time of deposition. We demonstrate that the shapes of the dose distributions can be used to assess the likelihood that aliquots consist only of grains that were well-bleached at the time of deposition. The more asymmetric the distribution, the greater the probability that the aliquots with the lowest dose most closely represent the true burial dose. Single grains with differing doses are present in each of the samples examined, and the population with the lowest dose gives an optical age consistent with the expected burial age. This result implies that the beta-dose heterogeneity in these deposits is small, and that the effects of micro-dosimetric variations on optical dati...

  20. Comparison of measured and calculated radiation doses in granite around emplacement holes in the spent-fuel test: Climax, Nevada Test Site

    International Nuclear Information System (INIS)

    van Konynenburg, R.A.

    1982-01-01

    Lawrence Livermore National Laboratory (LLNL) has emplaced eleven spent nuclear-reactor fuel assemblies in the Climax granite at the Nevada Test Site as part of the DOE Nevada Nuclear-Waste Storage Investigations. One of our objectives is to study radiation effects on the rock. The neutron and gamma-ray doses to the rock have been determined by MORSE-L Monte Carlo calculations and measurements using optical absorption and thermoluminescence dosimeters and metal foils. We compare the results to date. Generally, good agreement is found in the spatial and time dependence of the doses, but some of the absolute dose results appear to differ by more than the expected uncertainties. Although the agreement is judged to be adequate for radiation effects studies, suggestions for improving the precision of the calculations and measurements are made

  1. Protection dose level in industrial non-destructive radiographic testing

    International Nuclear Information System (INIS)

    Su Xieming; Deng Daping; Hou Jinpeng

    1992-01-01

    The relationship between scattered beams in radiation field, different tube-voltages, and thickness of steel plates was studied by experiments. The results show that radio parent ratio increases with increasing tube-voltage and decreases with the increasing thickness of steel plates. As scattering angle rises, the scattering ratio decreases slowly, and the lowest ratio is at 180 degree

  2. Dose-response testing with nickel sulphate using the TRUE test in nickel-sensitive individuals. Multiple nickel sulphate patch-test reactions do not cause an 'angry back'

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Lidén, C; Hansen, J

    1993-01-01

    The aim of this study was to employ the TRUE test assay to confirm the presence or absence of the 'angry back' phenomenon, i.e. that a strong positive patch-test reaction heightens adjacent patch-test response. In addition, we wished to establish the dose-response relationship for nickel sulphate...... back' phenomenon was not apparent in this study, as the spill-over effect was not statistically significant. Strong reactions to high concentrations of nickel sulphate did not enhance the response to adjacent lower concentrations of nickel sulphate....

  3. Proceedings of an international workshop on historic dose experience and dose reduction (ALARA) at nuclear power plants

    International Nuclear Information System (INIS)

    Horan, J.R.; Baum, J.W.; Dionne, B.J.

    1985-06-01

    Dose reduction data and experience from 28 foreign and 10 US nuclear power plants was examined to determine causes for the wide variations in occupational dose from country to country. Major topics discussed were: steam generator and refueling maintenance problems; utility and supplier ALARA programs; effectiveness of dose-reduction modifications; attitudes and training; current and future dose-reduction research. While many parameters contribute to differences of occupational doses between plants from different nations, it is clear that most US plants have higher collective dose equivalent per reactor per megawatt-year than most other countries, even for plants of similar size and age. Worldwide, Finnish and Swedish plants, both PWR and BWR, have achieved the lowest values. Major factors which contribute to low doses include: (1) minimization of cobalt in primary system components exposed to water; (2) careful plant design, layout and component segregation and shielding; (3) plant standardization; (4) selection of components and systems for increased reliability; (5) management interest and commitment; (6) minimum number of workers and in-depth worker training; (7) careful control of primary system oxygen and pH; (8) good primary system water purity to minimize corrosion product formation; (9) use of special tools and robotics; (10) decontamination and passivation of primary systems and components; and (11) extent of backfitting and mandated inspections

  4. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    International Nuclear Information System (INIS)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-01-01

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED adj ). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED adj between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED adj that differed by up to 44% from effective dose estimates that were not

  5. Bayesian dose selection design for a binary outcome using restricted response adaptive randomization.

    Science.gov (United States)

    Meinzer, Caitlyn; Martin, Renee; Suarez, Jose I

    2017-09-08

    In phase II trials, the most efficacious dose is usually not known. Moreover, given limited resources, it is difficult to robustly identify a dose while also testing for a signal of efficacy that would support a phase III trial. Recent designs have sought to be more efficient by exploring multiple doses through the use of adaptive strategies. However, the added flexibility may potentially increase the risk of making incorrect assumptions and reduce the total amount of information available across the dose range as a function of imbalanced sample size. To balance these challenges, a novel placebo-controlled design is presented in which a restricted Bayesian response adaptive randomization (RAR) is used to allocate a majority of subjects to the optimal dose of active drug, defined as the dose with the lowest probability of poor outcome. However, the allocation between subjects who receive active drug or placebo is held constant to retain the maximum possible power for a hypothesis test of overall efficacy comparing the optimal dose to placebo. The design properties and optimization of the design are presented in the context of a phase II trial for subarachnoid hemorrhage. For a fixed total sample size, a trade-off exists between the ability to select the optimal dose and the probability of rejecting the null hypothesis. This relationship is modified by the allocation ratio between active and control subjects, the choice of RAR algorithm, and the number of subjects allocated to an initial fixed allocation period. While a responsive RAR algorithm improves the ability to select the correct dose, there is an increased risk of assigning more subjects to a worse arm as a function of ephemeral trends in the data. A subarachnoid treatment trial is used to illustrate how this design can be customized for specific objectives and available data. Bayesian adaptive designs are a flexible approach to addressing multiple questions surrounding the optimal dose for treatment efficacy

  6. The Semipalatinsk nuclear test site: a first assessment of the radiological situation and the test-related radiation doses in the surrounding territories.

    Science.gov (United States)

    Gusev, B I; Abylkassimova, Z N; Apsalikov, K N

    1997-09-01

    As a result of atmospheric nuclear tests at the Semipalatinsk test site 'Polygon', adjacent territories were contaminated by radionuclide fallout. The population of some districts in the Semipalatinsk oblast were exposed to elevated levels of radiation. Contamination and exposure mostly resulted from early atmospheric tests. The radiological situation of the Semipalatinsk oblast is described. Effective dose estimates due to external and internal exposure attributable to the 1949 and 1953 tests in villages near the Polygon range from 70 mSv to 4470 mSv.

  7. External contamination and skin dose. From ICRP and regulations to skin dose evaluation in practice

    International Nuclear Information System (INIS)

    Le Coulteulx, I.; Apretna, D.; Beaugerie, M.; Fenolland, J.; Frey, R.; Gonin, M.; Landry, B.; Laporte, E.; Le Guen, B.; Leval, D.

    2006-01-01

    Dose limitation to the skin is an objective of radiation protection. Our aim is to propose in case of skin contamination in EDF NPPs a simply, quickly and reproducible procedure for evaluating skin dose. French regulation admit an annual limit for skin dose over one square centimeter equal to 500 mSv. ICRP Publication 26 and 60 recommend that dose assessment be performed only if skin dose might be equal to or more than 50 mSv at basal cells. To respect this recommendation, an alert value (A) must be determined. This value is the lowest value of measurement from which dose assessment has to be made, based on the hypothesis that uninterrupted work time in controlled area is no more than four hours. This alert value (A) has been established for three external detection equipments, and for the ten radionuclides commonly detected. In case of external contamination, a first measurement is performed. If the value exceeds value (A), other measurements are instituted because skin dose evaluation needs to know other parameters as: - the radioactivity of the most contaminated square centimeter of the skin, - the identity of the radionuclides and their relative proportion. At the same time, we have to evaluate the length of the exposure. At last, we use different compiled results in a program developed from excel software which allow to calculate automatically the skin dose. This work has allowed us to publish an occupational health guideline about the assessment of skin dose in case of external contamination in EDF NPPs and to create an information booklet for workers. The authors propose to examine used methodology and to demonstrate the software. (authors)

  8. Rationality, irrationality and escalating behavior in lowest unique bid auctions.

    Directory of Open Access Journals (Sweden)

    Filippo Radicchi

    Full Text Available Information technology has revolutionized the traditional structure of markets. The removal of geographical and time constraints has fostered the growth of online auction markets, which now include millions of economic agents worldwide and annual transaction volumes in the billions of dollars. Here, we analyze bid histories of a little studied type of online auctions--lowest unique bid auctions. Similarly to what has been reported for foraging animals searching for scarce food, we find that agents adopt Lévy flight search strategies in their exploration of "bid space". The Lévy regime, which is characterized by a power-law decaying probability distribution of step lengths, holds over nearly three orders of magnitude. We develop a quantitative model for lowest unique bid online auctions that reveals that agents use nearly optimal bidding strategies. However, agents participating in these auctions do not optimize their financial gain. Indeed, as long as there are many auction participants, a rational profit optimizing agent would choose not to participate in these auction markets.

  9. Rationality, Irrationality and Escalating Behavior in Lowest Unique Bid Auctions

    Science.gov (United States)

    Radicchi, Filippo; Baronchelli, Andrea; Amaral, Luís A. N.

    2012-01-01

    Information technology has revolutionized the traditional structure of markets. The removal of geographical and time constraints has fostered the growth of online auction markets, which now include millions of economic agents worldwide and annual transaction volumes in the billions of dollars. Here, we analyze bid histories of a little studied type of online auctions – lowest unique bid auctions. Similarly to what has been reported for foraging animals searching for scarce food, we find that agents adopt Lévy flight search strategies in their exploration of “bid space”. The Lévy regime, which is characterized by a power-law decaying probability distribution of step lengths, holds over nearly three orders of magnitude. We develop a quantitative model for lowest unique bid online auctions that reveals that agents use nearly optimal bidding strategies. However, agents participating in these auctions do not optimize their financial gain. Indeed, as long as there are many auction participants, a rational profit optimizing agent would choose not to participate in these auction markets. PMID:22279553

  10. Reconstruction of absorbed dose by methods biological dosimetry inhabitans living in Semipalatinsk Nuclear Test Site

    International Nuclear Information System (INIS)

    Abildinova, G.

    2010-01-01

    As a result perennial overland and atmospheric test the nucleus weapon on Semipalatinsk nucler test site (NTS) about 1,2 ml person were subjected to frequentative sharp and chronic irradiation in different range of doses. Besides a significant number of battle radioactive matters tests with radionuclei dispersion on soil surface and an atmosphere was realized also. All this activity has caused the significant radioactive contamination and damage to an environment, and the local population has received extra exposure to radiation. These circumstances have essentially complicated the economy development of the given region. Aim: Reconstruction of absorbed dose by modern methods biological dosimetry beside inhabitants living in region of influence Semipalatinsk NTS. The cytogenetically examination of population Semipalatinsk region, living in different zones radiation risk: s. Dolon, s. Sarzhal, s. Mostik. Installed that total frequency of chromosome aberrations forms 4,8/100; 2,1/100; 2,5/100 cells, accordingly. High level of chromosome aberrations is conditioned to account radiations markers - acentric fragments (2,1/100 cells in s. Dolon; 1,09/100 cells in s. Sarzhal; 0,79/100 cells in s. Mostik); dysenteric and ring chromosomes (0,6; 0,2; 0,11) and stable type chromosome aberrations (1,02; 0,3; 1,0, accordingly). Frequency and spectrum of chromosome aberrations are indicative of significant mutation action ionizing radiations on chromosome device of somatic cells. Studied dependency an cytogenetically of effects from dose of irradiation within before 0,5 Gr in vitro for calibrated curve standard when undertaking reconstruction efficient dose at the time of irradiations examined group of population. Dependency is described the model a*cos(x) 1 + sin (x), where x - correlation a dysenteric and ring chromosomes to acentric fragments. Dependence of cytogenetic parameters upon ESR-doses had been studied. Had been received dependences: for the total frequency of

  11. PAH toxicity at aqueous solubility in the fish embryo test with Danio rerio using passive dosing

    DEFF Research Database (Denmark)

    Seiler, Thomas-Benjamin; Best, Nina; Fernqvist, Margit Møller

    2014-01-01

    to animal testing in (eco)toxicology. However, for hydrophobic organic chemicals it remains a technical challenge to ensure constant freely dissolved concentration at the maximum exposure level during such biotests. Passive dosing with PDMS silicone was thus applied to control the freely dissolved...... further data to support the close relationship between the chemical activity and the toxicity of hydrophobic organic compounds. Passive dosing from PDMS silicone enabled reliable toxicity testing of (highly) hydrophobic substances at aqueous solubility, providing a practical way to control toxicity...... exactly at the maximum exposure level. This approach is therefore expected to be useful as a cost-effective initial screening of hydrophobic chemicals for potential adverse effects to freshwater vertebrates....

  12. Imaging and Measuring Electron Beam Dose Distributions Using Holographic Interferometry

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.

    1975-01-01

    Holographic interferometry was used to image and measure ionizing radiation depth-dose and isodose distributions in transparent liquids. Both broad and narrowly collimated electron beams from accelerators (2–10 MeV) provided short irradiation times of 30 ns to 0.6 s. Holographic images...... and measurements of absorbed dose distributions were achieved in liquids of various densities and thermal properties and in water layers thinner than the electron range and with backings of materials of various densities and atomic numbers. The lowest detectable dose in some liquids was of the order of a few k......Rad. The precision limits of the measurement of dose were found to be ±4%. The procedure was simple and the holographic equipment stable and compact, thus allowing experimentation under routine laboratory conditions and limited space....

  13. Dose Distribution of Gamma Irradiators

    International Nuclear Information System (INIS)

    Park, Seung Woo; Shin, Sang Hun; Son, Ki Hong; Lee, Chang Yeol; Kim, Kum Bae; Jung, Hai Jo; Ji, Young Hoon

    2010-01-01

    Gamma irradiator using Cs-137 have been widely utilized to the irradiation of cell, blood, and animal, and the dose measurement and education. The Gamma cell 3000 Elan (Nordion International, Kanata, Ontario, Canada) irradiator was installed in 2003 with Cs-137 and dose rate of 3.2 Gy/min. And the BioBeam 8000 (Gamma-Service Medical GmbH, Leipzig, Germany) irradiator was installed in 2008 with Cs-137 and dose rate of 3.5 Gy/min. Our purpose was to evaluate the practical dosimetric problems associated with inhomogeneous dose distribution within the irradiated volume in open air state using glass dosimeter and Gafchromic EBT film dosimeter for routine Gamma irradiator dosimetry applications at the KIRAMS and the measurements were compared with each other. In addition, an user guideline for useful utilization of the device based on practical dosimetry will be prepared. The measurement results of uniformity of delivered dose within the device showed variation more than 14% between middle point and the lowest position at central axis. Therefore, to maintain dose variation within 10%, the criteria of useful dose distribution, for research radiation effects, the irradiated specimen located at central axis of the container should be placed within 30 mm from top and bottom surface, respectively. In addition, for measurements using the film, the variations of dose distribution were more then 50% for the case of less than 10 second irradiation, mostly within 20% for the case of more than 20 second irradiation, respectively. Therefore, the irradiation experiments using the BioBeam 8000 irradiator are recommended to be used for specimen required at least more than 20 second irradiation time.

  14. Threshold dose for behavioral discrimination of cigarette nicotine content in menthol vs. non-menthol smokers.

    Science.gov (United States)

    Perkins, Kenneth A; Kunkle, Nicole; Karelitz, Joshua L

    2017-04-01

    The lowest threshold content (or "dose") of nicotine discriminated in cigarettes may differ due to menthol preference. Menthol and non-menthol Spectrum research cigarettes differing in nicotine content were used to determine discrimination thresholds. Dependent smokers preferring menthol (n = 40) or non-menthol (n = 21) brands were tested on ability to discriminate cigarettes (matched for their menthol preference) with nicotine contents of 16-17, 11-12, 5, 2, and 1 mg/g, one per session, from an "ultra-low" cigarette with 0.4 mg/g. Controlled exposure to each cigarette was four puffs/trial, and the number of sessions was determined by the lowest nicotine content they could discriminate on >80% of trials (i.e., ≥5 of 6). We also assessed subjective perceptions and behavioral choice between cigarettes to relate them to discrimination responses. Controlling for Fagerstrom Test of Nicotine Dependence score, discrimination thresholds were more likely to be at higher nicotine content cigarettes for menthol vs. non-menthol smokers (p vs. 11 mg/g, respectively. Compared to the ultra-low, threshold and subthreshold (next lowest) cigarettes differed on most perceptions and puff choice, but menthol preference did not alter these associations. Notably, threshold cigarettes did, but subthreshold did not, increase choice over the ultra-low. Threshold for discriminating nicotine via smoking may be generally higher for menthol vs. non-menthol smokers. More research is needed to identify why menthol smoking is related to higher nicotine thresholds and to verify that cigarettes unable to be discriminated do not support reinforcement.

  15. CT radiation dose and image quality optimization using a porcine model.

    Science.gov (United States)

    Zarb, Francis; McEntee, Mark F; Rainford, Louise

    2013-01-01

    To evaluate potential radiation dose savings and resultant image quality effects with regard to optimization of commonly performed computed tomography (CT) studies derived from imaging a porcine (pig) model. Imaging protocols for 4 clinical CT suites were developed based on the lowest milliamperage and kilovoltage, the highest pitch that could be set from current imaging protocol parameters, or both. This occurred before significant changes in noise, contrast, and spatial resolution were measured objectively on images produced from a quality assurance CT phantom. The current and derived phantom protocols were then applied to scan a porcine model for head, abdomen, and chest CT studies. Further optimized protocols were developed based on the same methodology as in the phantom study. The optimization achieved with respect to radiation dose and image quality was evaluated following data collection of radiation dose recordings and image quality review. Relative visual grading analysis of image quality criteria adapted from the European guidelines on radiology quality criteria for CT were used for studies completed with both the phantom-based or porcine-derived imaging protocols. In 5 out of 16 experimental combinations, the current clinical protocol was maintained. In 2 instances, the phantom protocol reduced radiation dose by 19% to 38%. In the remaining 9 instances, the optimization based on the porcine model further reduced radiation dose by 17% to 38%. The porcine model closely reflects anatomical structures in humans, allowing the grading of anatomical criteria as part of image quality review without radiation risks to human subjects. This study demonstrates that using a porcine model to evaluate CT optimization resulted in more radiation dose reduction than when imaging protocols were tested solely on quality assurance phantoms.

  16. Stress corrosion testing of irradiated cladding tubes

    International Nuclear Information System (INIS)

    Lunde, L.; Olshausen, K.D.

    1980-01-01

    Samples from two fuel rods with different cladding have been stress corrosion tested by closed-end argon-iodine pressurization at 320 0 C. The fuel rods with stress relieved and recrystallized Zircaloy-2 had received burnups of 10.000 and 20.000 MWd/ton UO 2 , respectively. It was found that the SCC failure stress was unchanged or slightly higher for the irradiated than for the unirradiated control tubes. The tubes failed consistently in the end with the lowest irradiation dose. The diameter increase of the irradiated cladding during the test was 1.1% for the stress-relieved samples and 0.24% for the recrystallized samples. SEM examination revealed no major differences between irradiated and unirradiated cladding. A ''semi-ductile'' fracture zone in recrystallized material is described in some detail. (author)

  17. Patient Dose From Megavoltage Computed Tomography Imaging

    International Nuclear Information System (INIS)

    Shah, Amish P.; Langen, Katja M.; Ruchala, Kenneth J.; Cox, Andrea; Kupelian, Patrick A.; Meeks, Sanford L.

    2008-01-01

    Purpose: Megavoltage computed tomography (MVCT) can be used daily for imaging with a helical tomotherapy unit for patient alignment before treatment delivery. The purpose of this investigation was to show that the MVCT dose can be computed in phantoms, and further, that the dose can be reported for actual patients from MVCT on a helical tomotherapy unit. Methods and Materials: An MVCT beam model was commissioned and verified through a series of absorbed dose measurements in phantoms. This model was then used to retrospectively calculate the imaging doses to the patients. The MVCT dose was computed for five clinical cases: prostate, breast, head/neck, lung, and craniospinal axis. Results: Validation measurements in phantoms verified that the computed dose can be reported to within 5% of the measured dose delivered at the helical tomotherapy unit. The imaging dose scaled inversely with changes to the CT pitch. Relative to a normal pitch of 2.0, the organ dose can be scaled by 0.67 and 2.0 for scans done with a pitch of 3.0 and 1.0, respectively. Typical doses were in the range of 1.0-2.0 cGy, if imaged with a normal pitch. The maximal organ dose calculated was 3.6 cGy in the neck region of the craniospinal patient, if imaged with a pitch of 1.0. Conclusion: Calculation of the MVCT dose has shown that the typical imaging dose is approximately 1.5 cGy per image. The uniform MVCT dose delivered using helical tomotherapy is greatest when the anatomic thickness is the smallest and the pitch is set to the lowest value

  18. Test methods of total dose effects in very large scale integrated circuits

    International Nuclear Information System (INIS)

    He Chaohui; Geng Bin; He Baoping; Yao Yujuan; Li Yonghong; Peng Honglun; Lin Dongsheng; Zhou Hui; Chen Yusheng

    2004-01-01

    A kind of test method of total dose effects (TDE) is presented for very large scale integrated circuits (VLSI). The consumption current of devices is measured while function parameters of devices (or circuits) are measured. Then the relation between data errors and consumption current can be analyzed and mechanism of TDE in VLSI can be proposed. Experimental results of 60 Co γ TDEs are given for SRAMs, EEPROMs, FLASH ROMs and a kind of CPU

  19. Methods to verify absorbed dose of irradiated containers and evaluation of dosimeters

    International Nuclear Information System (INIS)

    Gao Meixu; Wang Chuanyao; Tang Zhangxong; Li Shurong

    2001-01-01

    The research on dose distribution in irradiated food containers and evaluation of several methods to verify absorbed dose were carried out. The minimum absorbed dose of treated five orange containers was in the top of the highest or in the bottom of lowest container. D max /D min in this study was 1.45 irradiated in a commercial 60 Co facility. The density of orange containers was about 0.391g/cm 3 . The evaluation of dosimeters showed that the PMMA-YL and clear PMMA dosimeters have linear relationship with dose response, and the word NOT in STERIN-125 and STERIN-300 indicators were covered completely at the dosage of 125 and 300 Gy respectively. (author)

  20. Researches and Applications of ESR Dosimetry for Radiation Accident Dose Assessment

    International Nuclear Information System (INIS)

    Wu, K.; Guo, L.; Cong, J.B.; Sun, C.P.; Hu, J.M.; Zhou, Z.S.; Wang, S.; Zhang, Y.; Zhang, X.; Shi, Y.M.

    1998-01-01

    The aim of this work was to establish methods suitable for practical dose assessment of people involved in ionising radiation accidents. Some biological materials of the human body and materials possibly carried or worn by people were taken as detection samples. By using electron spin resonance (ESR) techniques, the basic dosimetric properties of selected materials were investigated in the range above the threshold dose of human acute haemopoietic radiation syndrome. The dosimetric properties involved included dose response properties of ESR signals, signal stabilities, distribution of background signals, the lowest detectable dose value, radiation conditions, environmental effects on the detecting process, etc. Several practical dose analytical indexes and detecting methods were set up. Some of them (bone, watch glass and tooth enamel) had also been successfully used in the dose assessment of people involved in three radiation accidents, including the Chernobyl reactor accident. This work further proves the important role of ESR techniques in radiation accident dose estimation. (author)

  1. Individualized FSH dosing based on ovarian reserve testing in women starting IVF/ICSI: a multicentre trial and cost-effectiveness analysis

    OpenAIRE

    van Tilborg, Theodora C.; Oudshoorn, Simone C.; Eijkemans, Marinus J. C.; Mochtar, Monique H.; van Golde, Ron J. T.; Hoek, Annemieke; Kuchenbecker, Walter K. H.; Fleischer, Kathrin; de Bruin, Jan Peter; Groen, Henk; van Wely, Madelon; Lambalk, Cornelis B.; Laven, Joop S. E.; Mol, Ben Willem J.; Broekmans, Frank J. M.

    2017-01-01

    STUDY QUESTION: Is there a difference in live birth rate and/or cost-effectiveness between antral follicle count (AFC)-based individualized FSH dosing or standard FSH dosing in women starting IVF or ICSI treatment? SUMMARY ANSWER: In women initiating IVF/ICSI, AFC-based individualized FSH dosing does not improve live birth rates or reduce costs as compared to a standard FSH dose. WHAT IS KNOWN ALREADY: In IVF or ICSI, ovarian reserve testing is often used to adjust the FSH dose in order to no...

  2. Adapting protocols of CT imaging in a pediatric emergency department. Evaluation of image quality and dose

    International Nuclear Information System (INIS)

    Batista Arce, A.; Gonzalez Lopez, S.; Catalan Acosta, A.; Casares Magaz, O.; Hernandez Armas, O.; Hernandez Armas, J.

    2011-01-01

    The purpose of this study was to assess qualitatively the picture quality in relation to the radiation dose delivered in CT studies of computer tomograph Pediatric Emergency Department of Hospital Universitario de Canarias (HUC) in order to optimize the technical parameters used these radiological examinations so as to obtain optimal image quality at the lowest possible dose.

  3. Ultralow dose dentomaxillofacial CT imaging and iterative reconstruction techniques: variability of Hounsfield units and contrast-to-noise ratio

    Science.gov (United States)

    Bischel, Alexander; Stratis, Andreas; Kakar, Apoorv; Bosmans, Hilde; Jacobs, Reinhilde; Gassner, Eva-Maria; Puelacher, Wolfgang; Pauwels, Ruben

    2016-01-01

    Objective: The aim of this study was to evaluate whether application of ultralow dose protocols and iterative reconstruction technology (IRT) influence quantitative Hounsfield units (HUs) and contrast-to-noise ratio (CNR) in dentomaxillofacial CT imaging. Methods: A phantom with inserts of five types of materials was scanned using protocols for (a) a clinical reference for navigated surgery (CT dose index volume 36.58 mGy), (b) low-dose sinus imaging (18.28 mGy) and (c) four ultralow dose imaging (4.14, 2.63, 0.99 and 0.53 mGy). All images were reconstructed using: (i) filtered back projection (FBP); (ii) IRT: adaptive statistical iterative reconstruction-50 (ASIR-50), ASIR-100 and model-based iterative reconstruction (MBIR); and (iii) standard (std) and bone kernel. Mean HU, CNR and average HU error after recalibration were determined. Each combination of protocols was compared using Friedman analysis of variance, followed by Dunn's multiple comparison test. Results: Pearson's sample correlation coefficients were all >0.99. Ultralow dose protocols using FBP showed errors of up to 273 HU. Std kernels had less HU variability than bone kernels. MBIR reduced the error value for the lowest dose protocol to 138 HU and retained the highest relative CNR. ASIR could not demonstrate significant advantages over FBP. Conclusions: Considering a potential dose reduction as low as 1.5% of a std protocol, ultralow dose protocols and IRT should be further tested for clinical dentomaxillofacial CT imaging. Advances in knowledge: HU as a surrogate for bone density may vary significantly in CT ultralow dose imaging. However, use of std kernels and MBIR technology reduce HU error values and may retain the highest CNR. PMID:26859336

  4. Exposure of the Heart in Breast Cancer Radiation Therapy: A Systematic Review of Heart Doses Published During 2003 to 2013

    International Nuclear Information System (INIS)

    Taylor, Carolyn W.; Wang, Zhe; Macaulay, Elizabeth; Jagsi, Reshma; Duane, Frances; Darby, Sarah C.

    2015-01-01

    Purpose: Breast cancer radiation therapy cures many women, but where the heart is exposed, it can cause heart disease. We report a systematic review of heart doses from breast cancer radiation therapy that were published during 2003 to 2013. Methods and Materials: Eligible studies were those reporting whole-heart dose (ie, dose averaged over the whole heart). Analyses considered the arithmetic mean of the whole-heart doses for the CT plans for each regimen in each study. We termed this “mean heart dose.” Results: In left-sided breast cancer, mean heart dose averaged over all 398 regimens reported in 149 studies from 28 countries was 5.4 Gy (range, <0.1-28.6 Gy). In regimens that did not include the internal mammary chain (IMC), average mean heart dose was 4.2 Gy and varied with the target tissues irradiated. The lowest average mean heart doses were from tangential radiation therapy with either breathing control (1.3 Gy; range, 0.4-2.5 Gy) or treatment in the lateral decubitus position (1.2 Gy; range, 0.8-1.7 Gy), or from proton radiation therapy (0.5 Gy; range, 0.1-0.8 Gy). For intensity modulated radiation therapy mean heart dose was 5.6 Gy (range, <0.1-23.0 Gy). Where the IMC was irradiated, average mean heart dose was around 8 Gy and varied little according to which other targets were irradiated. Proton radiation therapy delivered the lowest average mean heart dose (2.6 Gy, range, 1.0-6.0 Gy), and tangential radiation therapy with a separate IMC field the highest (9.2 Gy, range, 1.9-21.0 Gy). In right-sided breast cancer, the average mean heart dose was 3.3 Gy based on 45 regimens in 23 studies. Conclusions: Recent estimates of typical heart doses from left breast cancer radiation therapy vary widely between studies, even for apparently similar regimens. Maneuvers to reduce heart dose in left tangential radiation therapy were successful. Proton radiation therapy delivered the lowest doses. Inclusion of the IMC doubled typical heart dose.

  5. Transcriptome profiling of mice testes following low dose irradiation

    DEFF Research Database (Denmark)

    Belling, Kirstine C.; Tanaka, Masami; Dalgaard, Marlene Danner

    2013-01-01

    ABSTRACT: BACKGROUND: Radiotherapy is used routinely to treat testicular cancer. Testicular cells vary in radio-sensitivity and the aim of this study was to investigate cellular and molecular changes caused by low dose irradiation of mice testis and to identify transcripts from different cell types...... in the adult testis. METHODS: Transcriptome profiling was performed on total RNA from testes sampled at various time points (n = 17) after 1 Gy of irradiation. Transcripts displaying large overall expression changes during the time series, but small expression changes between neighbouring time points were...... selected for further analysis. These transcripts were separated into clusters and their cellular origin was determined. Immunohistochemistry and in silico quantification was further used to study cellular changes post-irradiation (pi). RESULTS: We identified a subset of transcripts (n = 988) where changes...

  6. Use of remifentanil to reduce propofol injection pain and the required propofol dose in upper digestive tract endoscopy diagnostic tests.

    Science.gov (United States)

    Uliana, Gustavo Nadal; Tambara, Elizabeth Milla; Baretta, Giorgio Alfredo Pedroso

    2015-01-01

    The introduction of propofol (2,6-diisopropylphenol) as a sedative agent has transformed the area of sedation for endoscopic procedures. However, a major drawback of sedation with the use of propofol is its high incidence of injection pain. The most widely used technique in reducing propofol injection pain is through the association of other drugs. The aim of this study was to evaluate the effect of remifentanil-propofol combination on the incidence of propofol injection pain and its influence on the total dose of propofol required for sedation in upper digestive tract endoscopy (UDE) diagnostic tests. One hundred and five patients undergoing upper digestive tract endoscopy were evaluated and randomly divided into 3 groups of 35 patients each. The Control Group received propofol alone; Study-group 1 received remifentanil at a fixed dose of 0.2mg/kg combined with propofol; Study-group 2 received remifentanil at a fixed dose of 0.3mg/kg combined with propofol. The incidence of propofol injection pain and the total dose of propofol required for the test were evaluated. The sample was very similar regarding age, weight, height, sex, and physical status. Statistical analysis was performed according to the nature of the evaluated data. Student's t-test was used to compare the mean of age, weight, height (cm), and dose (mg/kg) variables between groups. The χ(2) test was used to compare sex, physical status, and propofol injection pain between groups. The significance level was αpain and total dose of propofol (mg/kg) used. However, there were no statistical differences between the two study groups for these parameters. We conclude that the use of remifentanil at doses of 0.2mg/kg and 0.3mg/kg was effective for reducing both the propofol injection pain and the total dose of propofol used. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  7. Fine structure of the lowest Landau level in suspended trilayer graphene

    NARCIS (Netherlands)

    van Elferen, H. J.; Veligura, A.; Tombros, N.; Kurganova, E. V.; van Wees, B. J.; Maan, J. C.; Zeitler, U.

    2013-01-01

    Magnetotransport experiments on ABC-stacked suspended trilayer graphene reveal a complete splitting of the 12-fold degenerated lowest Landau level, and, in particular, the opening of an exchange-driven gap at the charge neutrality point. A quantitative analysis of distinctness of the quantum Hall

  8. Dose rate laser simulation tests adequacy: Shadowing and high intensity effects analysis

    International Nuclear Information System (INIS)

    Nikiforov, A.Y.; Skorobogatov, P.K.

    1996-01-01

    The adequacy of laser based simulation of the flash X-ray effects in microcircuits may be corrupted mainly due to laser radiation shadowing by the metallization and the non-linear absorption in a high intensity range. The numerical joint solution of the optical equations and the fundamental system of equations in a two-dimensional approximation were performed to adjust the application range of laser simulation. As a result the equivalent dose rate to laser intensity correspondence was established taking into account the shadowing as well as the high intensity effects. The simulation adequacy was verified in the range up to 4·10 11 rad(Si)/s with the comparative laser test of a specially designed test structure

  9. Repeated dose 90-day oral toxicity test of G-7% NANA in rats: An application of new criterion for toxicity determination to test article-induced changes.

    Science.gov (United States)

    Heo, Hye Seon; An, MinJi; Lee, Ji Sun; Kim, Hee Kyong; Park, Yeong-Chul

    2018-06-01

    G-7% NANA is N-acetylneuraminic acid(NANA) containing 7% sialic acid isolated from glycomacropeptide (GMP), a compound of milk. Since NANA is likely to have immunotoxicity, the need to ensure safety for long-term administration has been raised. In this study, a 90-day repeated oral dose toxicity test was performed in rats using G-7% NANA in the dosages of 0, 1250, 2500 and 5000 mg/kg/day.A toxicity determination criterion based on the significant change caused by the administration of the substancewas developed for estimating NOEL, NOAEL and LOAELapplied to this study. When analyzing the immunological markers, no significant changes were observed, even if other significant changes were observed in the high dose group. In accordance with the toxicity determination criterion developed, the NOEL in male and female has been determined as 2500 mg/kg/day, and the NOAEL in females has been determined as 5000 mg/kg/day. The toxicity determination criterion, applied for the first time in the repeated dose toxicity tests, could provide a basis for distinguishing NOEL and NOAEL more clearly; nevertheless, the toxicity determination criterion needs to be supplemented by adding differentiating adverse effects and non-adverse effects based on more experiences of the repeated dose toxicity tests. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    Energy Technology Data Exchange (ETDEWEB)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan [Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States) and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States)

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose

  11. Comparison of image quality in head CT studies with different dose-reduction strategies

    DEFF Research Database (Denmark)

    Johansen, Jeppe; Nielsen, Rikke; Fink-Jensen, Vibeke

    The number of multi-detector CT examinations is increasing rapidly. They allow high quality reformatted images providing accurate and precise diagnosis at maximum speed. Brain examinations are the most commonly requested studies, and although they come at a lower effective dose than body CT, can...... account to a considerable radiation dose as many patients undergo repeated studies. Therefore, various dose-reduction strategies are applied such as automated tube current and voltage modulation and recently different iterative reconstruction algorithms. However, the trade-off of all dose......-reduction maneuvers is reduction of image quality due to image noise or artifacts. The aim of our study was therefore to find the best diagnostic images with lowest possible dose. We present results of dose- and image quality optimizing strategies of brain CT examinations at our institution. We compare sequential...

  12. Effect of low dose radiation on somatic intrachromosomal recombination in vivo and in vitro

    International Nuclear Information System (INIS)

    Hooker, A.M.; Cormack, J.; Morley, A.A.; Sykes, P.J.; Bhat, M.

    2003-01-01

    Full text: High doses of ionising radiation are mutagenic in a wide range of mutation assays. The majority of radiation exposure studies in in vivo mouse mutation assays have been performed at high doses, eg greater than 1 Gy. However, these doses are not relevant to the low doses of ionising radiation that the majority of the population might likely come into contact with. Radiation protection levels tend to be based on a simple linear no-threshold model which suggests that any radiation above zero is potentially harmful. The pKZ1 recombination mutagenesis mouse model has proven to be a sensitive assay for the detection of mutations caused by low doses of chemical agents. In pKZ1 mice, somatic intrachromosomal recombination (SICR) inversion events can be detected in cells using histochemistry for the E. coli LacZ transgene. We exposed pKZ1 mice to a single radiation dose ranging from 0.001 to 2 Gy. A significant increase in SICR was observed in spleen at the two highest doses of 0.1 and 2 Gy and a significant reduction in SICR below the endogenous frequency was observed at the two lowest doses of 0.01 and 0.001 Gy. After exposing a pKZ1 cell line to the same dose range, a similar J curve response was observed with significant increases in SICR observed at the 3 highest doses and a significant decrease below the endogenous frequency at the lowest dose (0.001 Gy). The next experiments will be to determine the dose where the SICR frequency returns to the endogenous level. The important question posed by these results is 'Is a reduction below the endogenous SICR level caused by low doses of ionising radiation anti-mutagenic?' Studies now need to be performed to investigate the effect of low doses of radiation on other mutation end-points, and the mechanism for the reduction in SICR

  13. Quality control tests in dose calibrators used in research laboratories of IPEN

    International Nuclear Information System (INIS)

    Kuahara, Lilian T.; Junior, Amaury C.R.; Martins, Elaine W.; Dias, Carla R.; Correa, Eduardo de L.; Potiens, Maria da Penha A.

    2013-01-01

    The aim of this study was to do the intercomparison between two dose calibrators used in research laboratories at IPEN-CNEN / SP, one being the Capinted NPL-CRC, of the Laboratorio de Calibracao de Instrumentos (LCI) do IPEN, and the other Capintec CRC-15R of the Centro de Radiofarmacia (CR). The standard sources used for carrying out the comparing tests between the two laboratories were 57 Co, 133 Ba and the 13 7 C s

  14. Establishment Success of the Beetle Tapeworm Hymenolepis diminuta Depends on Dose and Host Body Condition

    Science.gov (United States)

    Jane Cassidy, Elizabeth; Vitt Meyling, Nicolai

    2018-01-01

    Parasite effects on host fitness and immunology are often intensity-dependent. Unfortunately, only few experimental studies on insect-parasite interactions attempt to control the level of infection, which may contribute substantial variation to the fitness or immunological parameters of interest. The tapeworm Hymenolepis diminuta—flour beetle Tenebrio molitor model—has been used extensively for ecological and evolutionary host–parasite studies. Successful establishment of H. diminuta cysticercoids in T. molitor relies on ingestion of viable eggs and penetration of the gut wall by the onchosphere. Like in other insect models, there is a lack of standardization of the infection load of cysticercoids in beetles. The aims of this study were to: (1) quantify the relationship between exposure dose and establishment success across several H. diminuta egg concentrations; and (2) test parasite establishment in beetles while experimentally manipulating host body condition and potential immune response to infection. Different egg concentrations of H. diminuta isolated from infected rat feces were fed to individual beetles 7–10 days after eclosion and beetles were exposed to starvation, wounding, or insertion of a nylon filament one hour prior to infection. We found that the establishment of cysticercoids in relation to exposure dose could be accurately predicted using a power function where establishment success was low at three lowest doses and higher at the two highest doses tested. Long-term starvation had a negative effect on cysticercoid establishment success, while insertion of a nylon filament and wounding the beetles did not have any effect compared to control treatment. Thus, our results show that parasite load may be predicted from the exposure dose within the observed range, and that the relationship between dose and parasite establishment success is able to withstand some changes in host body condition. PMID:29401652

  15. Establishment Success of the Beetle Tapeworm Hymenolepis diminuta Depends on Dose and Host Body Condition

    Directory of Open Access Journals (Sweden)

    Suraj Dhakal

    2018-02-01

    Full Text Available Parasite effects on host fitness and immunology are often intensity-dependent. Unfortunately, only few experimental studies on insect-parasite interactions attempt to control the level of infection, which may contribute substantial variation to the fitness or immunological parameters of interest. The tapeworm Hymenolepis diminuta—flour beetle Tenebrio molitor model—has been used extensively for ecological and evolutionary host–parasite studies. Successful establishment of H. diminuta cysticercoids in T. molitor relies on ingestion of viable eggs and penetration of the gut wall by the onchosphere. Like in other insect models, there is a lack of standardization of the infection load of cysticercoids in beetles. The aims of this study were to: (1 quantify the relationship between exposure dose and establishment success across several H. diminuta egg concentrations; and (2 test parasite establishment in beetles while experimentally manipulating host body condition and potential immune response to infection. Different egg concentrations of H. diminuta isolated from infected rat feces were fed to individual beetles 7–10 days after eclosion and beetles were exposed to starvation, wounding, or insertion of a nylon filament one hour prior to infection. We found that the establishment of cysticercoids in relation to exposure dose could be accurately predicted using a power function where establishment success was low at three lowest doses and higher at the two highest doses tested. Long-term starvation had a negative effect on cysticercoid establishment success, while insertion of a nylon filament and wounding the beetles did not have any effect compared to control treatment. Thus, our results show that parasite load may be predicted from the exposure dose within the observed range, and that the relationship between dose and parasite establishment success is able to withstand some changes in host body condition.

  16. Low-dose thioperamide injected into the cerebellar vermis of mice immediately after exposure to the elevated plus-maze impairs their avoidance behavior on re-exposure to the apparatus

    Directory of Open Access Journals (Sweden)

    J. Costa Neto

    2013-11-01

    Full Text Available The present study investigated the effect of thioperamide (THIO, an H3 histaminergic receptor antagonist, microinjected into the cerebellar vermis on emotional memory consolidation in male Swiss albino mice re-exposed to the elevated plus-maze (EPM. We implanted a guide cannula into the cerebellar vermis using stereotactic surgery. On the third day after surgery, we performed behavioral tests for two consecutive days. On the first day (exposure, the mice (n=10/group were exposed to the EPM and received THIO (0.06, 0.3, or 1.5 ng/0.1 µL immediately after the end of the session. Twenty-four hours later, the mice were re-exposed to the EPM under the same experimental conditions, but without drug injection. A reduction in the exploration of the open arms upon re-exposure to the EPM (percentage of number of entries and time spent in open arms compared with the initial exposure was used as an indicator of learning and memory. One-way analysis of variance (ANOVA followed by the Duncan post hoc test was used to analyze the data. Upon re-exposure, exploratory activity in the open arms was reduced in the control group, and with the two highest THIO doses: 0.3 and 1.5 ng/0.1 µL. No reduction was seen with the lowest THIO dose (0.06 ng/0.1 µL, indicating inhibition of the consolidation of emotional memory. None of the doses interfered with the animals' locomotor activity. We conclude that THIO at the lowest dose (0.06 ng/0.1 µL microinjected into the cerebellum impaired emotional memory consolidation in mice.

  17. Evaluation of X ray radiation doses in pediatric examinations of cranial computerized tomography based on optimization studies; Avaliacao das doses de radiacao X em exames pediatricos de tomografia computadorizada de cranio com base em estudos de otimizacao

    Energy Technology Data Exchange (ETDEWEB)

    Daros, Kellen Adriana Curci

    2005-07-01

    This paper identifies the technical conditions for CT examination which offers lowest absorbed dose and to attend the manufacturer recommendations as far the spatial resolution is concerned. The paper evaluates the absorbed dose during cranial CT in up to 6 years children satisfying the technical condition recommended by the manufacturer and routine clinical conditions. The paper also established a quantitative relationship among the absorbed dose and its distribution in the cranial regions of pediatric patients up to 6 years old in a way to estimate the doses subject to optimized conditions

  18. High and Low Doses of Ionizing Radiation Induce Different Secretome Profiles in a Human Skin Model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qibin; Matzke, Melissa M.; Schepmoes, Athena A.; Moore, Ronald J.; Webb-Robertson, Bobbie-Jo M.; Hu, Zeping; Monroe, Matthew E.; Qian, Weijun; Smith, Richard D.; Morgan, William F.

    2014-03-18

    It is postulated that secreted soluble factors are important contributors of bystander effect and adaptive responses observed in low dose ionizing radiation. Using multidimensional liquid chromatography-mass spectrometry based proteomics, we quantified the changes of skin tissue secretome – the proteins secreted from a full thickness, reconstituted 3-dimensional skin tissue model 48 hr after exposure to 3, 10 and 200 cGy of X-rays. Overall, 135 proteins showed statistical significant difference between the sham (0 cGy) and any of the irradiated groups (3, 10 or 200 cGy) on the basis of Dunnett adjusted t-test; among these, 97 proteins showed a trend of downregulation and 9 proteins showed a trend of upregulation with increasing radiation dose. In addition, there were 21 and 8 proteins observed to have irregular trends with the 10 cGy irradiated group either having the highest or the lowest level among all three radiated doses. Moreover, two proteins, carboxypeptidase E and ubiquitin carboxyl-terminal hydrolase isozyme L1 were sensitive to ionizing radiation, but relatively independent of radiation dose. Conversely, proteasome activator complex subunit 2 protein appeared to be sensitive to the dose of radiation, as rapid upregulation of this protein was observed when radiation doses were increased from 3, to 10 or 200 cGy. These results suggest that different mechanisms of action exist at the secretome level for low and high doses of ionizing radiation.

  19. Radiation dose reduction in the evaluation of scoliosis: an application of digital radiography

    International Nuclear Information System (INIS)

    Kushner, D.C.; Cleveland, R.H.; Herman, T.E.; Zaleske, D.J.; Ehrlich, M.G.; Correia, J.A.

    1986-01-01

    This report documents the clinical testing of scanning beam digital radiography as an imaging method in patients with scoliosis. This type of digital imaging requires a skin exposure of only 2.4 mR (0.619 microC/kg) per image, compared with the lowest possible posteroanterior screen-film exposure of 10 mR (2.58 microC/kg) at the chest and 60 mR (15.48 microC/kg) at the lumbar spine. Digital radiographic and screen-film images were obtained on multiple test objects and 273 patients. Scoliosis measurements using screen-film radiographs and digital radiographs were comparable to within a mean difference of 1 degrees at many different degrees of severity. The low-dose digital images were found to be useful and accurate for the detection and measurement of scoliosis after the first screen-film radiographs have excluded tumors and structural abnormalities

  20. Patterns of prednisone use during pregnancy in women with rheumatoid arthritis: Daily and cumulative dose.

    Science.gov (United States)

    Palmsten, Kristin; Rolland, Matthieu; Hebert, Mary F; Clowse, Megan E B; Schatz, Michael; Xu, Ronghui; Chambers, Christina D

    2018-04-01

    To characterize prednisone use in pregnant women with rheumatoid arthritis using individual-level heat-maps and clustering individual trajectories of prednisone dose, and to evaluate the association between prednisone dose trajectory groups and gestational length. This study included pregnant women with rheumatoid arthritis who enrolled in the MotherToBaby Autoimmune Diseases in Pregnancy Study (2003-2014) before gestational week 20 and reported prednisone use without another oral glucocorticoid during pregnancy (n = 254). Information on medication use and pregnancy outcomes was collected by telephone interview plus by medical record review. Prednisone daily dose and cumulative dose were plotted by gestational day using a heat map for each individual. K-means clustering was used to cluster individual trajectories of prednisone dose into groups. The associations between trajectory group and demographics, disease severity measured by the Health Assessment Questionnaire at enrollment, and gestational length were evaluated. Women used prednisone 3 to 292 days during pregnancy, with daily doses ranging from <1 to 60 mg. Total cumulative dose ranged from 8 to 6225 mg. Disease severity, non-biologic disease modifying anti-rheumatic drug use, and gestational length varied significantly by trajectory group. After adjusting for disease severity, non-biologic disease modifying anti-rheumatic drug use, and other covariates, the highest vs lowest daily dose trajectory group was associated with reduced gestational age at delivery (β: -2.3 weeks (95%: -3.4, -1.3)), as was the highest vs lowest cumulative dose trajectory group (β: -2.6 weeks (95%: -3.6, -1.5)). In pregnant women with rheumatoid arthritis, patterns of higher prednisone dose were associated with shorter gestational length compared with lower dose. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Reducing dose in head CT: A phantom study

    International Nuclear Information System (INIS)

    Perez Diaz, M.; Carvalho, A. E.; Andrade, M. E.; Khoury, H. J.

    2013-01-01

    Thirty two head CT scans were acquired employing an anthropomorphic phantom which contains small lesions in posterior fosse, using 2 scanners, one with 64 slices 'Siemens Sensation' and other with 6 slices P hilip Brilliance . Parameters as Tube current (I [mA]), Collimation (C [mm]), spectrum energy (kVp) and dynamic range were changed during studies, looking for the optimal acquisition/processing conditions which permit both, good lesion detectability and the lowest dose. Air kerma (mGy) was measured with a ionization chamber and the air kerma index (Ca,100 [mGy]) was calculated as dose index. Image quality was analyzed by 5 expert criteria using a 5 points-scale (1=poor, 2=fair, 3=good, 4=very good, 5=excellent) and also using 5 Figure of merit in the spatial and frequency domains: Contrast C(%), Contrast to Noise Ratio CNR, Signal to Noise Ratio SNR, Normalized Mean Square Error (NMSE) and the Spectral Distance (SD). Objective and subjective results were correlated. We observed that doses can be diminished until a 25% respect to the usual practice with both technologies, diminishing mainly the mAs, without affecting lesion detection. As a result, we propose an optimized protocol for each scanner as follow: The use of 250 mAs, 120 kVp and the collimation of 6 slices x 1.50 mm per rotation to detect the lesions in posterior fosse with good image quality for the Philips Brilliance 6 tested, while 150 mAs, 100 kVp and slice thickness of 3 mm were needed with the Siemens Sensation 64. (Author)

  2. Chern-Simons field theory of two-dimensional electrons in the lowest Landau level

    International Nuclear Information System (INIS)

    Zhang, L.

    1996-01-01

    We propose a fermion Chern-Simons field theory describing two-dimensional electrons in the lowest Landau level. This theory is constructed with a complete set of states, and the lowest-Landau-level constraint is enforced through a δ functional described by an auxiliary field λ. Unlike the field theory constructed directly with the states in the lowest Landau level, this theory allows one, utilizing the physical picture of open-quote open-quote composite fermion,close-quote close-quote to study the fractional quantum Hall states by mapping them onto certain integer quantum Hall states; but, unlike its application in the unconstrained theory, such a mapping is sensible only when interactions between electrons are present. An open-quote open-quote effective mass,close-quote close-quote which characterizes the scale of low energy excitations in the fractional quantum Hall systems, emerges naturally from our theory. We study a Gaussian effective theory and interpret physically the dressed stationary point equation for λ as an equation for the open-quote open-quote mass renormalization close-quote close-quote of composite fermions. copyright 1996 The American Physical Society

  3. [Value of desmopressin stimulation test and high dose dexamethasone suppression testin the etiologic diagnosis of ACTH dependent Cushing's syndrome].

    Science.gov (United States)

    Zhang, Weiwei; Yu, Yerong; Tan, Huiwen; Wang, Chun; Li, Jianwei; An, Zhenmei; Liu, Yuping

    2016-03-22

    To investigate the value of desmopressin (DDAVP) stimulation test and high dose dexamethasone suppression test (HDDST) in establishing the cause of ACTH dependent Cushing's syndrome. The clinical data of patients with ACTH dependent Cushing's syndrome at West China Hospital from January 1, 2010 to September 30, 2015 was analyzed. The sensitivity and specificity of DDAVP stimulation test, HDDST, and the diagnostic accordance rate when the two tests were combined, were evaluated based on the diagnostic gold standard. A total of 85 patients with Cushing's disease and 10 patients with ectopic ACTH syndrome were included. The sensitivity and specificity of DDAVP stimulation test were 87% and 5/5, respectively, whereas those of HDDST were 79% and 8/10, respectively. The standard high dose dexamethasone suppression test showed a higher sensitivity than overnight 8 mg dexamethasone suppression test. When the two tests had consistent results, the diagnostic accordance rate was 100%. DDAVP stimulation test and HDDST are both efficient modalities for the diagnosis of Cushing's Disease and ectopic ACTH syndrome. The accuracy of diagnosis can be further improved by combining the two tests.

  4. Formation of low friction and wear-resistant carbon coatings on tool steel by 75keV, high-dose carbon ion implantation

    International Nuclear Information System (INIS)

    Mikkelsen, N.J.; Eskildsen, S.S.; Straede, C.A.; Chechenin, N.G.

    1994-01-01

    Hardened AISI D2 steel samples were subjected to mass-separated C + ion bombardment at 75keV with ion doses in the range 0.5-15x10 18 C + cm -2 . It was observed that sputtering was still limited, and the system exhibited internal growth, because most of the ions penetrated more than 0.1μm into the growing carbon film. At the lowest ion doses applied, carbon was implanted into the steel, while higher doses resulted in the implanted carbon concentration near the surface being almost 100%. For the highest doses applied, Rutherford backscattering spectrometry and surface profilometry analyses showed that layers about 0.5-1μm thick of almost pure carbon grew outward from the steel substrate. Transmission electron microscopy showed that the carbon layers were amorphous and exhibited an intermixed layer-substrate interface. The layers were hard and exhibited pronounced elastic recovery when subjected to ultralow load indentation. Low friction and excellent wear properties were measured when tested under dry conditions with a ball-on-disc tribometer. ((orig.))

  5. Intra-patient comparison of reduced-dose model-based iterative reconstruction with standard-dose adaptive statistical iterative reconstruction in the CT diagnosis and follow-up of urolithiasis

    Energy Technology Data Exchange (ETDEWEB)

    Tenant, Sean; Pang, Chun Lap; Dissanayake, Prageeth [Peninsula Radiology Academy, Plymouth (United Kingdom); Vardhanabhuti, Varut [Plymouth University Peninsula Schools of Medicine and Dentistry, Plymouth (United Kingdom); University of Hong Kong, Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, Pokfulam (China); Stuckey, Colin; Gutteridge, Catherine [Plymouth Hospitals NHS Trust, Plymouth (United Kingdom); Hyde, Christopher [University of Exeter Medical School, St Luke' s Campus, Exeter (United Kingdom); Roobottom, Carl [Plymouth University Peninsula Schools of Medicine and Dentistry, Plymouth (United Kingdom); Plymouth Hospitals NHS Trust, Plymouth (United Kingdom)

    2017-10-15

    To evaluate the accuracy of reduced-dose CT scans reconstructed using a new generation of model-based iterative reconstruction (MBIR) in the imaging of urinary tract stone disease, compared with a standard-dose CT using 30% adaptive statistical iterative reconstruction. This single-institution prospective study recruited 125 patients presenting either with acute renal colic or for follow-up of known urinary tract stones. They underwent two immediately consecutive scans, one at standard dose settings and one at the lowest dose (highest noise index) the scanner would allow. The reduced-dose scans were reconstructed using both ASIR 30% and MBIR algorithms and reviewed independently by two radiologists. Objective and subjective image quality measures as well as diagnostic data were obtained. The reduced-dose MBIR scan was 100% concordant with the reference standard for the assessment of ureteric stones. It was extremely accurate at identifying calculi of 3 mm and above. The algorithm allowed a dose reduction of 58% without any loss of scan quality. A reduced-dose CT scan using MBIR is accurate in acute imaging for renal colic symptoms and for urolithiasis follow-up and allows a significant reduction in dose. (orig.)

  6. Assessment of diurnal systemic dose of agrochemicals in regulatory toxicity testing--an integrated approach without additional animal use.

    Science.gov (United States)

    Saghir, Shakil A; Bartels, Michael J; Rick, David L; McCoy, Alene T; Rasoulpour, Reza J; Ellis-Hutchings, Robert G; Sue Marty, M; Terry, Claire; Bailey, Jason P; Billington, Richard; Bus, James S

    2012-07-01

    Integrated toxicokinetics (TK) data provide information on the rate, extent and duration of systemic exposure across doses, species, strains, gender, and life stages within a toxicology program. While routine for pharmaceuticals, TK assessments of non-pharmaceuticals are still relatively rare, and have never before been included in a full range of guideline studies for a new agrochemical. In order to better understand the relationship between diurnal systemic dose (AUC(24h)) and toxicity of agrochemicals, TK analyses in the study animals is now included in all short- (excluding acute), medium- and long-term guideline mammalian toxicity studies including reproduction/developmental tests. This paper describes a detailed procedure for the implementation of TK in short-, medium- and long-term regulatory toxicity studies, without the use of satellite animals, conducted on three agrochemicals (X11422208, 2,4-D and X574175). In these studies, kinetically-derived maximum doses (KMD) from short-term studies instead of, or along with, maximum tolerated doses (MTD) were used for the selection of the high dose in subsequent longer-term studies. In addition to leveraging TK data to guide dose level selection, the integrated program was also used to select the most appropriate method of oral administration (i.e., gavage versus dietary) of test materials for rat and rabbit developmental toxicity studies. The integrated TK data obtained across toxicity studies (without the use of additional/satellite animals) provided data critical to understanding differences in response across doses, species, strains, sexes, and life stages. Such data should also be useful in mode of action studies and to improve human risk assessments. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Single-dose Intramuscular-injection Toxicology Test of Water-soluble Carthami-flos and Cervi cornu parvum Pharmacopuncture in a Rat Model

    Directory of Open Access Journals (Sweden)

    Sunju Park

    2015-09-01

    Full Text Available Objectives: The aim of the study is to investigate both the single-dose intramuscular injection toxicity and the approximate lethal dose of water-soluble Carthami-flos and Cervi cornu parvum pharmacopuncture (WCFC in male and female Sprague-Dawley (SD rats. Methods: The study was conducted at Biotoxtech Co. according to the Good Laboratory Practice (GLP regulation and the toxicity test guidelines of the Ministry of Food and Drug Safety (MFDS after approval of the Institutional Animal Care and Use Committee. Dosages for the control, high dose, middle dose and low dose groups were 0.5 mL/animal of saline and 0.5, 0.25 and 0.125 mL/animal of WCFC, respectively. WCFC was injected into the muscle of the left femoral region by using a disposable syringe (1 mL, 26 gauge. The general symptoms and mortality were observed 30 minutes, 1, 2, 4, and 6 hours after the first injection and then daily for 14 days after the injection. The body weights of the SD rats were measured on the day of the injection (before injection and on the third, seventh, and fourteenth days after the injection. Serum biochemical and hematologic tests, necropsy examinations, and histopathologic examinations at the injection site were performed after the observation period. Results: No deaths, abnormal clinical symptoms, or significant weight changes were observed in either male or female SD rats in the control or the test (0.125, 0.25, and 0.5 mL/animal groups during the observation period. No significant differences in hematology and serum biochemistry and no macroscopic abnormalities at necropsy were found. No abnormal reactions at injection sites were noted on the topical tolerance tests. Conclusion: The results of this single-dose toxicity study show that WCFC is safe, its lethal doses in male and female SD rats being estimated to be higher than 0.5 mL/animal.

  8. TH-CD-202-08: Feasibility Study of Planning Phase Optimization Using Patient Geometry-Driven Information for Better Dose Sparing of Organ at Risks

    Energy Technology Data Exchange (ETDEWEB)

    Kang, S; Kim, D; Kim, T; Park, S; Shin, D; Kim, K; Cho, M; Suh, T [Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Kim, S [Virginia Commonwealth University, Richmond, VA (United States)

    2016-06-15

    Purpose: To propose a simple and effective cost value function to search optimal planning phase (gating window) and demonstrated its feasibility for respiratory correlated radiation therapy. Methods: We acquired 4DCT of 10 phases for 10 lung patients who have tumor located near OARs such as esophagus, heart, and spinal cord (i.e., central lung cancer patients). A simplified mathematical optimization function was established by using overlap volume histogram (OVH) between the target and organ at risk (OAR) at each phase and the tolerance dose of selected OARs to achieve surrounding OARs dose-sparing. For all patients and all phases, delineation of the target volume and selected OARs (esophagus, heart, and spinal cord) was performed (by one observer to avoid inter-observer variation), then cost values were calculated for all phases. After the breathing phases were ranked according to cost value function, the relationship between score and dose distribution at highest and lowest cost value phases were evaluated by comparing the mean/max dose. Results: A simplified mathematical cost value function showed noticeable difference from phase to phase, implying it is possible to find optimal phases for gating window. The lowest cost value which may result in lower mean/max dose to OARs was distributed at various phases for all patients. The mean doses of the OARs significantly decreased about 10% with statistical significance for all 3 OARs at the phase with the lowest cost value. Also, the max doses of the OARs were decreased about 2∼5% at the phase with the lowest cost value compared to the phase with the highest cost value. Conclusion: It is demonstrated that optimal phases (in dose distribution perspective) for gating window could exist differently through each patient and the proposed cost value function can be a useful tool for determining such phases without performing dose optimization calculations. This research was supported by the Mid-career Researcher Program

  9. Background radiation dose and leukemia mortality in north Japan

    International Nuclear Information System (INIS)

    Sakka, Masatoshi

    1978-01-01

    In 7 prefectures in north Japan where natural environment as well as socioeconomic status are similar, the relation of natural background dose rate and death rate caused by leukemia was examined. More than 2500 deaths were recorded in the last 10 years which distributed normally throughout the entire area with a mean of 3.68 and a SD of 1.14 per 10 5 per year. There are no significant, differences in the observed values of each prefecture in spite of having different population. Natural background radiation dose rate has also a normal distribution with a mean of 8.98 μR/h and a SD of 2.12. The highest dose rate in Niigata (10.44) was significantly higher than the lowest value in Aomori (6.48) whereas the death rates caused by leukemia were not different between the both prefectures. The null hypothesis that a positive regression exists between dose rate and death rate even in the smallest dose range was not supported in north Japan. Leukemogenic effect of background radiation, if any, seems to be within a practical threshold. (auth.)

  10. Evaluation of X ray radiation doses in pediatric examinations of cranial computerized tomography based on optimization studies

    International Nuclear Information System (INIS)

    Daros, Kellen Adriana Curci

    2005-01-01

    This paper identifies the technical conditions for CT examination which offers lowest absorbed dose and to attend the manufacturer recommendations as far the spatial resolution is concerned. The paper evaluates the absorbed dose during cranial CT in up to 6 years children satisfying the technical condition recommended by the manufacturer and routine clinical conditions. The paper also established a quantitative relationship among the absorbed dose and its distribution in the cranial regions of pediatric patients up to 6 years old in a way to estimate the doses subject to optimized conditions

  11. Effect of two doses of carbamylated allergoid extract of dust mite on nasal reactivity.

    Science.gov (United States)

    Scalone, G; Compalati, E; Bruno, M E; Mistrello, G

    2013-11-01

    Background and Objective. Single SLIT studies with native allergen extracts support a dose-response effect for clinical and immunological outcomes. Conversely for carbamylated allergoids this dose-response effects is less evident, likely because the threshold for efficacy is more easily reached through the enhanced bioavailability of the extract consequent to the selective chemical modification. Thus this pilot study investigates the dose-response effect on nasal specific reactivity and safety of two unusual doses of carbamylated allergoid in patients mono-sensitized to house dust mites. Methods. A prospective open randomized study involved 6-65 year-old Italian patients with clinically relevant sensitization to house dust mites and positive response to nasal provocation challenge. Monomeric carbamylated allergoid was delivered once daily at the dose of 1000 AU or 2000 AU from June to September 2009, during the lowest level of mites exposure. Primary outcomes were the change of the threshold of allergen concentration for a positive nasal provocation test (NPT) before and after the treatment and the product safety. Secondary outcome was the change  in the mean percentage fall of peak nasal inspiratory flow (PNIF) following nasal challenge. Results. Thirty-four patients were enrolled. Fifteen in group 1 and 14 in group 2 concluded the study. After 12 weeks all patients treated in group 1 and all but one in group 2 showed an increase in the threshold dose provoking a positive NPT. Those with no symptoms onset with the highest dose delivered were 80% in group 1 and 78.6% in group 2 (p=0.92). From first to second challenge, the mean percentage fall of PNIF  was reduced with no statistical difference between groups (p=0.95), and with no difference between the final mean percentage falls (p=0.65). No serious adverse reactions occurred and the frequency of events, all mild, was similar in the two groups. Conclusions. Twelve weeks of carbamylated sublingual allergoid

  12. Conditioned instrumental behaviour in the rat: Effects of prenatal irradiation with various low dose-rate doses

    International Nuclear Information System (INIS)

    Klug, H.

    1986-01-01

    4 groups of rats of the Wistar-strain were subjected to γ-irradiation on the 16th day of gestation. 5 rats received 0,6 Gy low dose rate irradiation, 5 animals received 0,9 Gy low dose and 6 high dose irradiation, 3 females were shamirradiated. The male offspring of these 3 irradiation groups and 1 control group were tested for locomotor coordination on parallel bars and in a water maze. The female offspring were used in an operant conditioning test. The locomotor test showed slight impairment of locomotor coordination in those animals irradiated with 0,9 Gy high dose rate. Swimming ability was significantly impaired by irradiation with 0,9 Gy high dose rate. Performance in the operant conditioning task was improved by irradiation with 0,9 Gy both low and high dose rate. The 0,9 Gy high dose rate group learned faster than all the other groups. For the dose of 0,9 Gy a significant dose rate effect could be observed. For the dose of 0,6 Gy a similar tendency was observed, differences between 0,6 Gy high and low dose rate and controls not being significant. (orig./MG) [de

  13. Evolution of late blood damage from decreasing doses of 241Am following injection in the rat

    International Nuclear Information System (INIS)

    Maillard, M.J.; Boncorps, Janine.

    1982-04-01

    Rats were given intravenous or intramuscular injections of 241 Am at decreasing doses ranging from 7.5 μCi to 0.075 μCi per kg of body weight. Blood examinations showed that higher doses exerted an irreversible destructive effect on all blood cells. As the administered doses decreased, the destructive effect of 241 Am dropped and even became reversible for white cells. Proliferative disorders such as leukocytosis with myelemias, leukemias -chiefly acute or chronic granulocytic leukemias- were then demonstrated. Red cells only dropped but more and more slowly. At the lowest doses, life-span shortening was the most evident effect [fr

  14. A dose-finding, cross-over study to evaluate the effect of a Nestorone®/Estradiol transdermal gel delivery on ovulation suppression in normal ovulating women.

    Science.gov (United States)

    Brache, Vivian; Merkatz, Ruth; Kumar, Narender; Jesam, Cristian; Sussman, Heather; Hoskin, Elena; Roberts, Kevin; Alami, Mohcine; Taylor, Deshawn; Jorge, Aidelis; Croxatto, Horacio; Lorange, Ellen; Mishell, Daniel R; Sitruk-Ware, Regine

    2015-10-01

    This study aims to determine the lowest effective of three Nestorone (NES)/estradiol (E2) transdermal gel doses to ensure ovulation suppression in 90-95% of cycles. This was a randomized, open-label, three-treatment-period cross-over study to evaluate the effects of NES/E2 transdermal gel on ovulation inhibition, suppression of follicular growth and pharmacokinetic parameters. The doses were low (1.5 mg NES/0.5 mg E2), medium (3.0 mg NES/1.0 mg E2) and high (4.5 mg NES/1.5 mg E2). Participants applied gel daily to a fixed area on the abdomen for 21 consecutive days. They were interviewed regarding their experiences using the gel. Eighteen participants were randomized; 16 completed the study. Median NES C(max) values for low, medium and high dose groups at day 21 were 318.6 pmol/L, 783.0 pmol/L and 1063.8 pmol/L, respectively. Median maximum follicular diameter was higher with the lowest dose with 16.2 mm versus 10.0 and 10.4 mm with the medium and high doses, respectively. Among adherent participants, ovulation was inhibited in all dose groups, except for one participant in the medium dose (6.7%) that had luteal activity and an ultrasound image suggestive of a luteinized unruptured follicle. There were few reports of unscheduled bleeding, with more episodes reported for the lower dose. Adverse events were mild, and no skin irritation was reported from gel application. While all three doses blocked ovulation effectively and were evaluated as safe and acceptable, the medium dose was considered the lowest effective dose based on a more adequate suppression of follicular development. Further development of this novel contraceptive delivering NES and E2 is warranted and has potential for improved safety compared to ethinyl-estradiol-based methods. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Dose evaluation in diagnostic for computerized tomography

    International Nuclear Information System (INIS)

    Flores, W.; Borges, J.C.; Mota, H.

    1998-01-01

    The patients which are subjected to computerized tomography tests are exposed to relatively high doses given as result doses on organs that are not matter to test. It was realized a dose levels raising in patients subjected to tests by T C, utilizing to measure this magnitude, TLD-100 thermoluminescent dosemeters which were put directly on the patient, in eye regions, thyroid, breast and navel; founding doses fluctuating between 29.10-49.39 mGy in organs examined and dose values between 0.21-29.10 mGy for organs that no matter to test. The applications of ionizing radiations in medicine do not have dose limits, but paying attention to the radiological protection optimization principle, it is recommended the use of clothes to anti-rays protection for zones not examined, getting with this to reduce the level doses as low as possible, without this to diminish the test quality. (Author)

  16. Dosimetric Comparison of 3-Dimensional Planning Techniques Using an Intravaginal Multichannel Balloon Applicator for High-Dose-Rate Gynecologic Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang-June, E-mail: spark@mednet.ucla.edu; Chung, Melody; Demanes, D. Jeffrey; Banerjee, Robyn; Steinberg, Michael; Kamrava, Mitchell

    2013-11-15

    Purpose: To study the dosimetric differences of various channel combinations of the Capri vaginal applicator. Methods and Materials: The Capri consists of a single central channel (R1), an inner array of 6 channels (R2), and an outer array of 6 channels (R3). Three-dimensional plans were simulated for 6 channel arrangements (R1, R2, R12, R13, R23, and R123). Treatment plans were optimized to the applicator surface or 5-mm depth while minimizing dose to organs at risk (OARs: bladder, rectum, sigmoid, and urethra). The clinical target volume (CTV) was defined as a 5-mm circumferential shell extending 4 cm in length around the applicator. Clinical target volume coverage (D{sub mean}, D{sub 90}, V{sub 100}, and V{sub 150}) and OAR doses (D{sub 0.1} {sub cm{sup 3}}, D{sub 1} {sub cm{sup 3}}, D{sub 2} {sub cm{sup 3}}, and D{sub mean}) were compared. A comparison between the Capri (R123) and a conventional single-channel applicator was also done. Statistical significance (P value <.05) was evaluated with a 2-tailed t test. Results: When prescribing to 5-mm depth, CTV coverage using all 13 channels (R123) versus a single channel (R1) was similar; however, when prescribing to the surface there were differences (P<.0001) in all CTV metrics except for the V{sub 150}. The R1 plans had higher doses to all OARs compared with R123 plans (P<.007). Doses to OARs were not significantly different between R23 and R123 plans (P=.05-.95), and CTV coverage differences were on the order of 1%. Capri R123 plans provided slightly lower CTV D{sub 90} and D{sub mean} but equivalent OAR doses with smaller standard deviations compared with conventional cylinder plans for both prescriptions. Conclusions: The Capri multichannel applicator provides equivalent target coverage at 5-mm depth, with significantly reduced dose to OARs relative to using a single channel. Optimal plans can be achieved using R12 (lowest V{sub 150}) or R123 or R23 (lowest OAR doses)

  17. Simulation of computed tomography dose based on voxel phantom

    Science.gov (United States)

    Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun

    2017-01-01

    Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.

  18. Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators

    International Nuclear Information System (INIS)

    Belley, Matthew D.; Wang, Chu; Nguyen, Giao; Gunasingha, Rathnayaka; Chao, Nelson J.; Chen, Benny J.; Dewhirst, Mark W.; Yoshizumi, Terry T.

    2014-01-01

    Purpose: Accurate dosimetry is essential when irradiating mice to ensure that functional and molecular endpoints are well understood for the radiation dose delivered. Conventional methods of prescribing dose in mice involve the use of a single dose rate measurement and assume a uniform average dose throughout all organs of the entire mouse. Here, the authors report the individual average organ dose values for the irradiation of a 12, 23, and 33 g mouse on a 320 kVp x-ray irradiator and calculate the resulting error from using conventional dose prescription methods. Methods: Organ doses were simulated in the Geant4 application for tomographic emission toolkit using the MOBY mouse whole-body phantom. Dosimetry was performed for three beams utilizing filters A (1.65 mm Al), B (2.0 mm Al), and C (0.1 mm Cu + 2.5 mm Al), respectively. In addition, simulated x-ray spectra were validated with physical half-value layer measurements. Results: Average doses in soft-tissue organs were found to vary by as much as 23%–32% depending on the filter. Compared to filters A and B, filter C provided the hardest beam and had the lowest variation in soft-tissue average organ doses across all mouse sizes, with a difference of 23% for the median mouse size of 23 g. Conclusions: This work suggests a new dose prescription method in small animal dosimetry: it presents a departure from the conventional approach of assigninga single dose value for irradiation of mice to a more comprehensive approach of characterizing individual organ doses to minimize the error and uncertainty. In human radiation therapy, clinical treatment planning establishes the target dose as well as the dose distribution, however, this has generally not been done in small animal research. These results suggest that organ dose errors will be minimized by calibrating the dose rates for all filters, and using different dose rates for different organs

  19. Thermoluminescence dose response of quartz as a function of irradiation temperature

    International Nuclear Information System (INIS)

    Kitis, G.; Kaldoudi, E.; Charalambous, S.

    1990-01-01

    The thermoluminescence (TL) response of pure Norwegian quartz as a function of irradiation temperature (T irr ) and dose has been investigated. The TL response of the (150-230 o C) and (230-350 o C) glow curve intervals shows a strong dependence on T irr between 77 and 373 K in the dose range from 54 to 8.4 x 10 4 Gy. Both glow curve intervals also show temperature dependent dose response properties. The 150-230 o C interval is supralinear from the lowest dose (54 Gy). Its maximum supralinearity factor appears at T irr = 293 K. The 230-350 o C interval shows sublinear behaviour below T irr = + 193 K, while at T irr ≥ 273 K it shows the well known dose response curves. Its maximum supralinearity factor appears at T irr = 323 K. The linear response is extended up to 460 Gy at T irr = 273 K and falls to 80 Gy at T irr = 373 K. (author)

  20. Review of low dose-rate epidemiological studies and biological mechanisms of dose-rate effects on radiation induced carcinogenesis

    International Nuclear Information System (INIS)

    Iwasaki, Toshiyasu; Otsuka, Kensuke; Yoshida, Kazuo

    2015-01-01

    Radiation protection system adopts the linear non-threshold model with using dose and dose-rate effectiveness factor (DDREF). The dose-rate range where DDREF is applied is below 100 mGy per hour, and it is regarded that there are no dose-rate effects at very low dose rate, less than of the order of 10 mGy per year, even from the biological risk evaluation model based on cellular and molecular level mechanisms for maintenance of genetic integrity. Among low dose-rate epidemiological studies, studies of residents in high natural background areas showed no increase of cancer risks at less than about 10 mGy per year. On the other hand, some studies include a study of the Techa River cohort suggested the increase of cancer risks to the similar degree of Atomic bomb survivor data. The difference of those results was supposed due to the difference of dose rate. In 2014, International Commission on Radiological Protection opened a draft report on stem cell biology for public consultations. The report proposed a hypothesis based on the new idea of stem cell competition as a tissue level quality control mechanism, and suggested that it could explain the dose-rate effects around a few milligray per year. To verify this hypothesis, it would be needed to clarify the existence and the lowest dose of radiation-induced stem cell competition, and to elucidate the rate of stem cell turnover and radiation effects on it. As for the turnover, replenishment of damaged stem cells would be the important biological process. It would be meaningful to collect the information to show the difference of dose rates where the competition and the replenishment would be the predominant processes. (author)

  1. Gender and dose dependent ovalbumin induced hypersensitivity responses in murine model of food allergy

    Science.gov (United States)

    While federal regulations mandate the labeling of major food allergens, allowable food allergen thresholds have yet to be determined. Therefore the aim of this project was to identify the lowest egg allergen ovalbumin (OVA) dose causing hypersensitization using a validated murine model. Mice were or...

  2. On dose distribution comparison

    International Nuclear Information System (INIS)

    Jiang, Steve B; Sharp, Greg C; Neicu, Toni; Berbeco, Ross I; Flampouri, Stella; Bortfeld, Thomas

    2006-01-01

    In radiotherapy practice, one often needs to compare two dose distributions. Especially with the wide clinical implementation of intensity-modulated radiation therapy, software tools for quantitative dose (or fluence) distribution comparison are required for patient-specific quality assurance. Dose distribution comparison is not a trivial task since it has to be performed in both dose and spatial domains in order to be clinically relevant. Each of the existing comparison methods has its own strengths and weaknesses and there is room for improvement. In this work, we developed a general framework for comparing dose distributions. Using a new concept called maximum allowed dose difference (MADD), the comparison in both dose and spatial domains can be performed entirely in the dose domain. Formulae for calculating MADD values for various comparison methods, such as composite analysis and gamma index, have been derived. For convenience in clinical practice, a new measure called normalized dose difference (NDD) has also been proposed, which is the dose difference at a point scaled by the ratio of MADD to the predetermined dose acceptance tolerance. Unlike the simple dose difference test, NDD works in both low and high dose gradient regions because it considers both dose and spatial acceptance tolerances through MADD. The new method has been applied to a test case and a clinical example. It was found that the new method combines the merits of the existing methods (accurate, simple, clinically intuitive and insensitive to dose grid size) and can easily be implemented into any dose/intensity comparison tool

  3. A novel concept for tumour targeting with radiation: Inverse dose-painting or targeting the "Low Drug Uptake Volume".

    Science.gov (United States)

    Yaromina, Ala; Granzier, Marlies; Biemans, Rianne; Lieuwes, Natasja; van Elmpt, Wouter; Shakirin, Georgy; Dubois, Ludwig; Lambin, Philippe

    2017-09-01

    We tested a novel treatment approach combining (1) targeting radioresistant hypoxic tumour cells with the hypoxia-activated prodrug TH-302 and (2) inverse radiation dose-painting to boost selectively non-hypoxic tumour sub-volumes having no/low drug uptake. 18 F-HX4 hypoxia tracer uptake measured with a clinical PET/CT scanner was used as a surrogate of TH-302 activity in rhabdomyosarcomas growing in immunocompetent rats. Low or high drug uptake volume (LDUV/HDUV) was defined as 40% of the GTV with the lowest or highest 18 F-HX4 uptake, respectively. Two hours post TH-302/saline administration, animals received either single dose radiotherapy (RT) uniformly (15 or 18.5Gy) or a dose-painted non-uniform radiation (15Gy) with 50% higher dose to LDUV or HDUV (18.5Gy). Treatment plans were created using Eclipse treatment planning system and radiation was delivered using VMAT. Tumour response was quantified as time to reach 3 times starting tumour volume. Non-uniform RT boosting tumour sub-volume with low TH-302 uptake (LDUV) was superior to the same dose escalation to HDUV (pvolume with no/low activity of hypoxia-activated prodrugs. This strategy applies on average a lower radiation dose and is as effective as uniform dose escalation to the entire tumour. It could be applied to other type of drugs provided that their distribution can be imaged. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  4. Estimation of effective dose from the atmospheric nuclear tests due to the intake of marine products

    International Nuclear Information System (INIS)

    Nakano, Masanao

    2008-01-01

    The worldwide environmental protection is required by the public. A long-term environmental assessment from nuclear fuel cycle facilities to the aquatic environment also becomes more important to understand long-term risk of nuclear energy. Evaluation of long-term risk including not only in Japan but also in neighboring countries is considered to be necessary in order to develop sustainable nuclear power industry. The author successfully simulated the distribution of radionuclides in seawater and seabed sediment produced by atmospheric nuclear tests using LAMER (Long-term Assessment ModEl of Radionuclides in the oceans). A part of the LAMER calculated the advection-diffusion-scavenging processes for radionuclides in the oceans and the Japan Sea in cooperate with Oceanic General Circulation Model (OGCM) and was validated. The author is challenging to calculate probabilistic effective dose suggested by ICRP from intake of marine products due to atmospheric nuclear tests using the Monte Carlo method in the other part of LAMER. Depending on the deviation of each parameter, the 95th percentile of the probabilistic effective dose was from one third to two thirds of the 95th percentile of the deterministic effective dose in proforma calculation. It means that probabilistic assessment can contribute to the design and optimisation of a nuclear fuel cycle facility. (author)

  5. Effect of Low Gamma Irradiation Doses on Growth and Productivity of Green Bean

    International Nuclear Information System (INIS)

    Mohamed, A.M.M.F.

    2011-01-01

    The field experiment was conducted within the two successive growing seasons of 2007/2008 and 2008/2009 to study the effect of low gamma irradiation doses (0, 10, 20, 30, 40, 50 and 60 Gy) on growth and productivity of green bean cv. Bronco with 3 sowing dates 8, 18 and 28th of October in the first season and 30th of September, 10 and 20th of October in the second season. The results of laboratory determinations showed that gamma irradiation doses did not affect the germination percent but slightly affected germination rate and electrical conductivity. Concerning field experiment, data revealed that green bean plant vegetative growth, i.e., plant height, fresh and dry weight, leaf number and leaf area, at 45 days after planting (DAP) and shoot number at 30, 45 DAP recorded significantly the highest values at the first sowing date in both seasons. With respect of gamma irradiation doses, all the previously mentioned parameters of plant vegetative growth recorded the highest values with 40 Gy at 15, 30, and 45 DAP except number of leaves which recorded the highest value with 30 Gy at 15, 30 and 45 DAP. Concerning shoot number there was no significant difference among several doses at 30 DAP in the first season but in the second season it was 20 Gy and at 45 DAP compared with the control. Also the first sowing date in both seasons gave the highest pod length, fresh and dry weight, plant yield, number of pods per plant, marketable yield per plot and total yield per feddan. Whereas ,the second sowing date led to the lowest pod thickness. In addition, 20 Gy of gamma irradiation doses recorded the highest value of pod length .The 30 Gy dose showed the highest value of pod fresh and dry weight, plant yield and total yield per feddan. In addition ,the 20 and 30 Gy doses led to the highest pod number per plant and marketable yield, concerning pod thickness there was slight difference only in the second season between several doses. The second sowing date in the first season

  6. An updated dose assessment for resettlement options at Bikini Atoll--a U.S. nuclear test site.

    Science.gov (United States)

    Robison, W L; Bogen, K T; Conrado, C L

    1997-07-01

    On 1 March 1954, a nuclear weapon test, code-named BRAVO, conducted at Bikini Atoll in the northern Marshall Islands contaminated the major residence island. There has been a continuing effort since 1977 to refine dose assessments for resettlement options at Bikini Atoll. Here we provide a radiological dose assessment for the main residence island, Bikini, using extensive radionuclide concentration data derived from analysis of food crops, ground water, cistern water, fish and other marine species, animals, air, and soil collected at Bikini Island as part of our continuing research and monitoring program that began in 1978. The unique composition of coral soil greatly alters the relative contribution of 137Cs and 90Sr to the total estimated dose relative to expectations based on North American and European soils. Without counter measures, 137Cs produces 96% of the estimated dose for returning residents, mostly through uptake from the soil to terrestrial food crops but also from external gamma exposure. The doses are calculated assuming a resettlement date of 1999. The estimated maximum annual effective dose for current island conditions is 4.0 mSv when imported foods, which are now an established part of the diet, are available. The 30-, 50-, and 70-y integral effective doses are 91 mSv, 130 mSv, and 150 mSv, respectively. A detailed uncertainty analysis for these dose estimates is presented in a companion paper in this issue. We have evaluated various countermeasures to reduce 137Cs in food crops. Treatment with potassium reduces the uptake of 137Cs into food crops, and therefore the ingestion dose, to about 5% of pretreatment levels and has essentially no negative environmental consequences. We have calculated the dose for the rehabilitation scenario where the top 40 cm of soil is removed in the housing and village area, and the rest of the island is treated with potassium fertilizer; the maximum annual effective dose is 0.41 mSv and the 30-, 50-, and 70-y

  7. Radiation dose of staff during positron emission tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Hachiya, Takenori; Shoji, Yasuaki; Hagami, Eiichi; Aizawa, Yasuo; Onodera, Hiroshi; Kan, Mikio; Sasaki, Nobuo; Toyoshima, Eiji; Sugawara, Shigeki

    1989-04-01

    In this paper, the radiation dose of the PET staff including blood sampling operators (medical doctors), PET operators (radio technologists), nurses, blood analysts (medical technologists), radiochemists and cyclotron operators in the cyclotron-PET unit was evaluated. The dose was measured using the film-badges for whole body and TLD ring-badges for fingers. These data were obtained from June, 1986 to May, 1987. In the average dose per month, those with the highest dose were radiochemists. The whole body dose was 1.08 mSv (108 mrem) for /gamma/-ray, 520 /mu/Sv (52 mrem) for /beta/-ray and the dose for fingers, 7.6mSv (760 mrem). The total dose per year both for /gamma/ and /beta/-ray was 19.2 mSv (1.92 rem) for whole body and 91.2 mSv (9.12 rem) for fingers. The staff with the lowest whole body dose for /gamma/-ray per month was blood analysts whose dose was 30 /mu/Sv (3 mrem). For the staff consisting of doctors, radiotechnologists and nurses, the whole body dose per month was 70-170/mu/Sv (7-17 mrem) for /gamma/-ray, 20 /mu/Sv (2 mrem) for /beta/-ray and the dose for fingers per month was 210-540 /mu/Sv (21-54 mrem). For cyclotron operators, the dose was 90 /mu/Sv (9 mrem) for /gamma/-ray, 30 /mu/Sv (3 mrem) for /beta/-ray and the dose for fingers was 160 /mu/Sv (16 mrem). For cyclotron operators and radiochemists, the whole body dose for the neutron ray was measured by solid state nuclear track detector (SSNTD), but the dose was found to be negligible. (author).

  8. Genetic radiation risks: a neglected topic in the low dose debate

    Directory of Open Access Journals (Sweden)

    Inge Schmitz-Feuerhake

    2016-01-01

    Full Text Available Objectives To investigate the accuracy and scientific validity of the current very low risk factor for hereditary diseases in humans following exposures to ionizing radiation adopted by the United Nations Scientific Committee on the Effects of Atomic Radiation and the International Commission on Radiological Protection. The value is based on experiments on mice due to reportedly absent effects in the Japanese atomic bomb (Abomb survivors. Methods To review the published evidence for heritable effects after ionising radiation exposures particularly, but not restricted to, populations exposed to contamination from the Chernobyl accident and from atmospheric nuclear test fallout. To make a compilation of findings about early deaths, congenital malformations, Down’s syndrome, cancer and other genetic effects observed in humans after the exposure of the parents. To also examine more closely the evidence from the Japanese A-bomb epidemiology and discuss its scientific validity. Results Nearly all types of hereditary defects were found at doses as low as one to 10 mSv. We discuss the clash between the current risk model and these observations on the basis of biological mechanism and assumptions about linear relationships between dose and effect in neonatal and foetal epidemiology. The evidence supports a dose response relationship which is non-linear and is either biphasic or supralinear (hogs-back and largely either saturates or falls above 10 mSv. Conclusions We conclude that the current risk model for heritable effects of radiation is unsafe. The dose response relationship is non-linear with the greatest effects at the lowest doses. Using Chernobyl data we derive an excess relative risk for all malformations of 1.0 per 10 mSv cumulative dose. The safety of the Japanese A-bomb epidemiology is argued to be both scientifically and philosophically questionable owing to errors in the choice of control groups, omission of internal exposure effects and

  9. Comparison of Adsorbed Skin Dose Received by Patients in Cone Beam Computed Tomography, Spiral and Conventional Computed Tomography Scanninng

    Directory of Open Access Journals (Sweden)

    Rahimi A

    2011-12-01

    Full Text Available Background and Aims: The evaluation of absorbed dose received by patients could give useful information for radiation risk estimation. This study was performed to compare the entrance skin dose received by patients in cone beam computed tomography (CBCT, conventional and spiral computed tomography (CT.Materials and Methods: In this experimental study, 81 calibrated TLD chips were used. the TLD chips were placed on facial, thyroid and end of sternum skin surface in patients referred for CT of the paranasal sinuses(3 TLD chips for each area to estimate the absorbed dose received by central part of radiation field, thyroid and out of field areas, respectively. The data were analyzed using one-way ANOVA and Tukey tests. Results: The dose delivered to the center of irradiated field was about 0.79±0.09 mGy in CBCT technique compared with 16.31±3.71 and 18.84±4.12 mGy for spiral and conventional CT, respectively. The received dose by the out of field areas was about 54 percent of central area dose. There was statistical significant relationship between the imaging modalities and absorbed dose received by patients (P=0.016. The least absorbed dose was for CBCT and the greatest dose was for conventional CT imaging technique.Conclusion: The dose delivered to central area of irradiated field in conventional and spiral CT imaging modalities was about 24 times greater than of that in CBCT. Also, the highest received dose was for central area of radiated field and the lowest dose was for the out of field areas.

  10. Assessment of the current internal dose due to 137Cs and 90Sr for people living within the Semipalatinsk Test Site, Kazakhstan.

    Science.gov (United States)

    Semiochkina, N; Voigt, G; Mukusheva, M; Bruk, G; Travnikova, I; Strand, P

    2004-02-01

    The Semipalatinsk Test Site in Kazakhstan was one of the major sites used by the USSR for testing nuclear weapons for more than 40 y. Since the early 1990's, responsibility for the site has passed to the Kazakh authorities. There has been a gradual re-establishment of agricultural use such as horse and sheep farming. Therefore, it has become important to evaluate the current and future risk to people living on and using the contaminated area. Internal dose assessment is one of the main components of the total dose when deriving risk factors for population living within the test site. Internal doses based on food monitoring and whole body measurements were calculated for adults and are in the range of 13-500 microSv y(-1) due to radiocesium and radiostrontium.

  11. A q-Schroedinger algebra, its lowest weight representations and generalized q-deformed heat equations

    International Nuclear Information System (INIS)

    Dobrev, V.K.; Doebner, H.D.; Mrugalla, C.

    1995-12-01

    We give a q-deformation S-perpendicular q of the centrally extended Schroedinger algebra. We construct the lowest weight representations of S-perpendicular q , starting from the Verma modules over S-perpendicular q , finding their singular vectors and factoring the Verma submodules built on the singular vectors. We also give a vector-field realization of S-perpendicular q which provides polynomial realization of the lowest weight representations and an infinite hierarchy of q-difference equations which may be called generalized q-deformed heat equations. We also apply our methods to the on-shell q-Schroedinger algebra proposed by Floreanini and Vinet. (author). 12 refs

  12. Angular dependence on the records of dose in radiochromic films strips

    Energy Technology Data Exchange (ETDEWEB)

    Costa, K. C.; Prata M, A. [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil); Alonso, T. C. [Centro de Desenvolvimento da Tecnologia Nuclear - CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil); Campo de O, P. M., E-mail: kamilacosta1995@gmail.com [Universidade Federal de Minas Gerais, Departamento de Anatomia e Imagen, Av. Prof. Alfredo Balena 190, 30130-100 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Radiological images have relevant information both the diagnostic results as to treatment decisions. Then, the diagnostic quality of image that allows a proper analysis should be achieved with the lowest possible deposition of dose in a patient. CT scans produce sectional images that allow the observation of internal structures of the human body without overlap. As in conventional radiology, the contrast which allows obtaining CT images results from the difference in X-ray beam absorption, according to the characteristics of each tissue. The increased of the beam absorption by a tissue means that it appears brighter in the image. In CT scanners, X-ray tube rotates around the patient, and this rotation results in a cross-sectional image of the body. From a sectional image series is possible to obtain a 3-dimensional image that can be viewed from different angles. Among the methods of dose measurement is the use of radiochromic films, which record the energy deposition by darkening its emulsion. The radiochromic films show little sensitivity to visible light and respond better to exposure to ionizing radiation. In this work, strips of the radiochromic film GAFCHROMIC XR-QA2 were irradiated at different angular positions for radiation quality RQT8, defining a beam of X-rays generated from a voltage of 100 kV. The response of radiochromic films depending on the doses was assessed through digital images obtained by H P Scan jet G-4050 scanner. Digital images were analyzed using Image-J software, which allowed obtaining numerical values corresponding to the intensity of darkening for each film. The aim of this study is to evaluate the dose deposition in radiochromic film according to the angular variation in order how is affected the record. So, to examine the use of film strips to record doses in Computed Tomography tests. (Author)

  13. A Pilot Study on Single-dose Toxicity Testing of Scolopendrid Pharmacopuncture in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Ilhong Son

    2014-06-01

    Full Text Available Objectives:This study was performed to analyze single dose toxicity and the lethal dose of Scolopendrid Pharmacopuncture in rats. Methods:All experiments were conducted at the Korea Testing & Research Institute (KTR, an institution authorized to perform non-clinical studies, under the regulations of Good Laboratory Practice (GLP. Sprague-Dawley rats were chosen for the pilot study. Doses of Scolopendrid pharmacopuncture, 0.1, 0.5, and 1.0 mL, were administered to the experimental group, and 1.0 mL doses of normal saline solution were administered to the control group. This study was conducted under the approval of the Institutional Animal Ethic Committee. Results:No deaths or abnormalities occurred in any of the groups. No significant changes in the weight, hematological parameters or clinical chemistry were noted between the control group and the experimental group. To check for abnormalities in organs and tissues, we used microscopy to examine representative histological sections of each specified organ; the results showed no significant differences in any of the organs or tissues. Conclusion:The above findings suggest Scolopendrid Pharmacopuncture is a relatively safe to use for treatment. Further studies on the subject should be conducted to yield more concrete evidence.

  14. Plants as warning signal for exposure to low dose radiation

    International Nuclear Information System (INIS)

    Rusli Ibrahim; Norhafiz Talib

    2012-01-01

    The stamen-hair system of Tradescantia for flower colour has proven to be one of the most suitable materials to study the frequency of mutations induced by low doses of various ionizing radiations and chemical mutagens. The system has also been used successfully for detecting mutagenic synergisms among chemical mutagens and ionizing radiations as well as for studying the variations of spontaneous mutation frequency. In this study of radiobiology, the main objective is to observe somatic mutation (occurrence of pink cells from blue cells) induced on stamen hairs of five Tradescantia sp. available in Malaysia after exposure to low doses of chronic gamma irradiation using Gamma Green House. Pink cells appeared only on Tradescantia Pallida Purpurea stamen hairs after 13 days of exposure to irradiation with different doses of gamma rays. The highest number of stamens with pink cells was recorded from flowers irradiated with the highest dose of 6.37 Gy with 0.07 Gy/ h of dose rate. The lowest number of stamens with pink cells was recorded with an average of 0.57, irradiated with the lowest dose of 0.91 Gy with 0.01 Gy/ h of dose rate. There were no pink cells observed on Tradescantia Spathaceae Discolor after exposure to different doses of gamma rays. Similar negative results were observed for the control experiments. The principal cells in this assay are the mitotic stamen hair cells developing in the young flower buds. After exposure to radiation, the heterozygous dominant blue character of the stamen hair cell is prevented, resulting in the appearance of the recessive pink color. Furthermore, no pink cell appears on all species of Tradescantia spathaceae after irradiated with different doses of gamma rays. The sensitivity of the Tradescantia has been used widely and has demonstrated the relation between radiation dose and frequency of mutation observed at low doses which can contribute to the effects of low doses and their consequences for human health. This system

  15. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    International Nuclear Information System (INIS)

    Abdollahi, Hamid; Shiri, Isaac; Salimi, Yazdan; Sarebani, Maghsoud; Mehdinia, Reza; Deevband, Mohammad Reza; Mahdavi, Seied Rabi; Sohrabi, Ahmad; Bitarafan-Rajabi, Ahmad

    2016-01-01

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  16. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Abdollahi, Hamid, E-mail: Hamid_rbp@yahoo.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Shiri, Isaac [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Salimi, Yazdan [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sarebani, Maghsoud; Mehdinia, Reza [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Deevband, Mohammad Reza [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Mahdavi, Seied Rabi [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Radiation Biology Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sohrabi, Ahmad [Department of Biostatistics, School of Public Health, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Bitarafan-Rajabi, Ahmad, E-mail: bitarafan@hotmail.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Department of Nuclear Medicine, Rajaei Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2016-12-15

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  17. Pre-installation empirical testing of room shielding for high dose rate remote afterloaders

    International Nuclear Information System (INIS)

    Klein, E.E.; Grigsby, P.W.; Williamson, J.F.; Meigooni, A.S.

    1993-01-01

    PURPOSE: Many facilities are acquiring high dose rate remote afterloading units. It is economical that these units be placed in existing shielded teletherapy rooms. Scatter-radiation barriers marginally protect uncontrolled areas from a high dose rate source especially in a room that houses a non-dynamic Cobalt-60 unit. In addition the exact thickness and material composition of the barriers are unknown and therefore, a calculation technique may give misleading results. Also, it would be impossible to evaluate an entire wall barrier by taking isolated core samples in order to assist in the calculations. A quick and inexpensive measurement of dose equivalent using a rented high activity 192Ir source evaluates the barriers and locates shielding deficiencies. METHODS AND MATERIALS: We performed transmission calculations for primary and scattered radiation based on National Council on Radiation Protection and Measurements Reports 49 and 51, respectively. We then rented a high activity 21.7 Ci (8.03 x 10(11) Bq) Ir-192 source to assess our existing teletherapy room shielding for adequacy and voids. This source was placed at the proposed location for clinical high dose rate treatment and measurements were performed. RESULTS: No deficiencies were found in controlled areas surrounding the room, but large differences were found between the calculated and measured values. Our survey located a region in the uncontrolled area above the room requiring augmented shielding which was not predicted by the calculations. A canopy shield was designed to potentially augment the shielding in the ceiling direction. CONCLUSION: Pre-installation testing by measurement is an invaluable method for locating shielding deficiencies and avoiding unnecessary enhancement of shielding particularly when there is lack of information of the inherent shielding

  18. Hippocampal dose volume histogram predicts Hopkins Verbal Learning Test scores after brain irradiation

    Directory of Open Access Journals (Sweden)

    Catherine Okoukoni, PhD

    2017-10-01

    Full Text Available Purpose: Radiation-induced cognitive decline is relatively common after treatment for primary and metastatic brain tumors; however, identifying dosimetric parameters that are predictive of radiation-induced cognitive decline is difficult due to the heterogeneity of patient characteristics. The memory function is especially susceptible to radiation effects after treatment. The objective of this study is to correlate volumetric radiation doses received by critical neuroanatomic structures to post–radiation therapy (RT memory impairment. Methods and materials: Between 2008 and 2011, 53 patients with primary brain malignancies were treated with conventionally fractionated RT in prospectively accrued clinical trials performed at our institution. Dose-volume histogram analysis was performed for the hippocampus, parahippocampus, amygdala, and fusiform gyrus. Hopkins Verbal Learning Test-Revised scores were obtained at least 6 months after RT. Impairment was defined as an immediate recall score ≤15. For each anatomic region, serial regression was performed to correlate volume receiving a given dose (VD(Gy with memory impairment. Results: Hippocampal V53.4Gy to V60.9Gy significantly predicted post-RT memory impairment (P < .05. Within this range, the hippocampal V55Gy was the most significant predictor (P = .004. Hippocampal V55Gy of 0%, 25%, and 50% was associated with tumor-induced impairment rates of 14.9% (95% confidence interval [CI], 7.2%-28.7%, 45.9% (95% CI, 24.7%-68.6%, and 80.6% (95% CI, 39.2%-96.4%, respectively. Conclusions: The hippocampal V55Gy is a significant predictor for impairment, and a limiting dose below 55 Gy may minimize radiation-induced cognitive impairment.

  19. Validation of clinical testing for warfarin sensitivity: comparison of CYP2C9-VKORC1 genotyping assays and warfarin-dosing algorithms.

    Science.gov (United States)

    Langley, Michael R; Booker, Jessica K; Evans, James P; McLeod, Howard L; Weck, Karen E

    2009-05-01

    Responses to warfarin (Coumadin) anticoagulation therapy are affected by genetic variability in both the CYP2C9 and VKORC1 genes. Validation of pharmacogenetic testing for warfarin responses includes demonstration of analytical validity of testing platforms and of the clinical validity of testing. We compared four platforms for determining the relevant single nucleotide polymorphisms (SNPs) in both CYP2C9 and VKORC1 that are associated with warfarin sensitivity (Third Wave Invader Plus, ParagonDx/Cepheid Smart Cycler, Idaho Technology LightCycler, and AutoGenomics Infiniti). Each method was examined for accuracy, cost, and turnaround time. All genotyping methods demonstrated greater than 95% accuracy for identifying the relevant SNPs (CYP2C9 *2 and *3; VKORC1 -1639 or 1173). The ParagonDx and Idaho Technology assays had the shortest turnaround and hands-on times. The Third Wave assay was readily scalable to higher test volumes but had the longest hands-on time. The AutoGenomics assay interrogated the largest number of SNPs but had the longest turnaround time. Four published warfarin-dosing algorithms (Washington University, UCSF, Louisville, and Newcastle) were compared for accuracy for predicting warfarin dose in a retrospective analysis of a local patient population on long-term, stable warfarin therapy. The predicted doses from both the Washington University and UCSF algorithms demonstrated the best correlation with actual warfarin doses.

  20. FREQUENCY OF CHROMOSOMAL ABERRATIONS AND MICRONUCLEI IN HORSE LYMPHOCYTES FOLLOWING IN VITRO EXPOSURE TO LOW DOSE IONISING RADIATION

    Directory of Open Access Journals (Sweden)

    Dunja Rukavina

    2012-07-01

    Full Text Available Ionising radiation is known to cause chromosomal instability, which is observed as increased frequency of chromosomal aberration and micronuclei. These are listed as reliable criteria in biological dosimetry. Numerous experiments conducted on both animal and plant models demonstrated that increase in radiation dosage is followed by increased mutation frequency, and that mutations occur even at the lowest exposure. We used horse blood in vitro irradiated by low doses of ionizing radiation. Cultivation of peripheral blood lymphocytes and micronucleus test were used as biomarkers of genetic damage. The observed aberrations were recorded and classified in accordance with the International System of Cytogenetic Nomenclature. Micronuclei were identified on the basis of criteria proposed by Fenech et al. (8. Analysis of chromosomal aberration showed increased frequency of aberrations in blood cultures exposed to 0,1 Gy and 0,2 Gy compared to the controls. Microscopic analysis of chromosomal damage in in vitro micronucleus test revealed that the applied radiation dose induced micronuclei while no binucleated cells with micronuclei were found in lymphocytes that were not irradiated. In this paper we analysed the influence of low dose ionising radiation on frequency of chromosomal aberration and micronuclei in horse lymphocytes following in vitro exposure to X-rays (0,1 Gy and 0,2 Gy. Key words: chromosomal aberrations, micronuclei, ionising radiation, horse lymphocytes

  1. Effect of radiation dose level on accuracy and precision of manual size measurements in chest tomosynthesis evaluated using simulated pulmonary nodules

    International Nuclear Information System (INIS)

    Soederman, Christina; Allansdotter Johnsson, Aase; Vikgren, Jenny; Rossi Norrlund, Rauni; Molnar, David; Svalkvist, Angelica; Maansson, Lars Gunnar; Baath, Magnus

    2016-01-01

    The aim of the present study was to investigate the dependency of the accuracy and precision of nodule diameter measurements on the radiation dose level in chest tomosynthesis. Artificial ellipsoid-shaped nodules with known dimensions were inserted in clinical chest tomosynthesis images. Noise was added to the images in order to simulate radiation dose levels corresponding to effective doses for a standard-sized patient of 0.06 and 0.04 mSv. These levels were compared with the original dose level, corresponding to an effective dose of 0.12 mSv for a standard-sized patient. Four thoracic radiologists measured the longest diameter of the nodules. The study was restricted to nodules located in high-dose areas of the tomosynthesis projection radiographs. A significant decrease of the measurement accuracy and intra-observer variability was seen for the lowest dose level for a subset of the observers. No significant effect of dose level on the interobserver variability was found. The number of non-measurable small nodules (≤5 mm) was higher for the two lowest dose levels compared with the original dose level. In conclusion, for pulmonary nodules at positions in the lung corresponding to locations in high-dose areas of the projection radiographs, using a radiation dose level resulting in an effective dose of 0.06 mSv to a standard-sized patient may be possible in chest tomosynthesis without affecting the accuracy and precision of nodule diameter measurements to any large extent. However, an increasing number of non-measurable small nodules (≤5 mm) with decreasing radiation dose may raise some concerns regarding an applied general dose reduction for chest tomosynthesis examinations in the clinical praxis. (authors)

  2. Tests of the linearity assumption in the dose-effect relationship for radiation-induced cancer

    International Nuclear Information System (INIS)

    Cohen, A.F.; Cohen, B.L.

    1978-01-01

    The validity of the BEIR linear extrapolation to low doses of the dose-effect relationship for radiation induced cancer is tested by use of natural radiation making use of selectivity on type of cancer, sex, age group, geographic area, and time period. For lung cancer, a linear interpolation between zero dose-zero effect and the data from radon-induced cancers in miners over-estimates the total number of observed lung cancers in many countries in the early years of this century; the discrepancy is substantially increased if the 30-44 year age range and/or if only females are considered, and by the fact that many other causes of lung cancer are shown to have been important at that time. The degree to which changes of diagnostic efficiency with time can influence the analysis is considered at some length. It is concluded that the linear relationship substantially over-estimates effects of low radiation doses. A similar analysis is applied to leukemia induced by natural radiation, applying selectivity by age, sex, natural background level, and date, and considering other causes. It is concluded that effects substantially larger than those obtained from linear extrapolation are excluded. The use of the selectivities mentioned above is justified by the fact that the incidence of cancer or leukemia is an upper limit on the rate at which it is caused by radiation effects; in determining upper limits it is justifiable to select situations which minimize it. (author)

  3. Characterization of silicates and calcium carbonates applied to high-dose dosimetry

    International Nuclear Information System (INIS)

    Vila, Gustavo Barreto

    2012-01-01

    The predominant isomorphous form in the biominerals studied in this work (oyster shell, coral, mother of pearl and shell) was aragonite. The appearance of the calcite phase occurred at 500 deg C at a heating rate of 10 deg C /s for all samples except for the coral sample, which was 400 deg C, independent of the heating rate. The most abundant element in the biominerals samples was Ca in the CaO form, and in the silicates (tremolite, diopside and rhodonite) Si in the SiO form. The most common trace element observed in the biominerals samples was Fe. The analyses of electron paramagnetic resonance showed lines of Mn 2+ in the coral and mother-of-pearl samples before irradiation. In the case of the irradiated samples, the defects found were CO 2 - , CO 3 3- , CO 3 - and SO 2 - , in the g range between 2.0010 and 2.0062. In the analyses by optical absorption of biominerals, transitions due to the presence of Mn in the samples were found. A thermoluminescent (TL) peak at approximately 140 deg C was found for the biominerals and at 180 deg C for silicates, which intensity depends directly on the dose. For samples exposed to different types of radiation, the TL peak occurred at lower temperatures. From the dose-response curves obtained for these materials, it was possible to determine a linear range for which their application in high dose dosimetry becomes possible. Taking into account the radiation type, among biominerals and silicates, the lowest detectable dose (40mGy) to gamma radiation was achieved for oyster shell samples using the measuring technique of optically stimulated luminescence (OSL). Using beta radiation, for diopside and tremolite samples the lowest detectable dose of 60mGy was obtained. For all samples, using the TL, OSL and thermally stimulated exoelectron emission (TSEE) techniques in alpha, beta and gamma radiation beans a good response reproducibility was obtained. Therefore, the samples characterized in this work are suitable to be used as high

  4. Olive baboons: a non-human primate model for testing dengue virus type 2 replication.

    Science.gov (United States)

    Valdés, Iris; Gil, Lázaro; Castro, Jorge; Odoyo, Damián; Hitler, Rikoi; Munene, Elephas; Romero, Yaremis; Ochola, Lucy; Cosme, Karelia; Kariuki, Thomas; Guillén, Gerardo; Hermida, Lisset

    2013-12-01

    This study evaluated the use of a non-human primate, the olive baboon (Papio anubis), as a model of dengue infection. Olive baboons closely resemble humans genetically and physiologically and have been used extensively for assessing novel vaccine formulations. Two doses of dengue virus type 2 (DENV-2) were tested in baboons: 10(3) and 10(4) pfu. Similarly, African green monkeys received the same quantity of virus and acted as positive controls. Following exposure, high levels of viremia were detected in both animal species. There was a trend to detect more days of viremia and more homogeneous viral titers in animals receiving the low viral dose. In addition, baboons infected with the virus generally exhibited positive virus isolation 1 day later than African green monkeys. Humoral responses consisting of antiviral and neutralizing antibodies were detected in all animals after infection. We conclude that baboons provide an alternative non-human primate species for experimental DENV-2 infection and we recommend their use for further tests of vaccines, administering the lowest dose assayed: 10(3) pfu. Copyright © 2013 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  5. A comparison of patient dose levels between 3/4 vessel conventional angiography and computed tomography angiography during examinations to investigate subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Spanton, David; Strudwick, Ruth M.

    2007-01-01

    The aim of this study was to investigate and compare the levels of ionising radiation dose received by patients whilst undergoing radiological examination for Subarachnoid haemorrhage by conventional angiography (single and bi plane) and computed tomography angiography. The results obtained from previous examinations have been compared to consider which method of investigation delivers the lowest ionising radiation dose to the patient. Consideration was also given to comparing single plane angiography to bi plane angiography as empirical evidence suggested that radiologists received no formal training and only a small amount of informal training on newly installed equipment at the hospital in which the research was carried out. Would this lead to patients being inadvertently exposed to increased radiation as radiologists familiarised themselves with the equipment? The dose received by 30 patients examined for SAH by each modality was converted to effective dose (mSv) for comparison. These results were then further compared by removing the lowest and highest recorded doses to eliminate any bias that may have been caused by skewed data. The results showed that CTA consistently delivered a lower dose to patients than single or bi plane angiography and that bi plane delivered a lower mean average dose than single plane angiography, with or without any skewed data

  6. [The dose estimation to the population as a result of radioactive contamination of the Semipalatinsk Test area].

    Science.gov (United States)

    Spiridonova, S I; Mukusheva, M K; Shubina, O A; Solomatin, V M; Epifanova, I E

    2008-01-01

    The results are presented from estimation of spatial distribution of 137Cs and 90Sr contamination densities in the areas of horses and sheep grazing within the Semipalatinsk Test Site. Dose burdens to various cohorts of the population living within the STS and consuming contaminated animal products are predicted. Doses of shepherds in the most contaminated pasture areas have been found to exceed the accepted limit (1 mSv/y). The conclusion is made about the need for further studies on the risk assessment of the STS population exposure above the accepted limits.

  7. A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models

    International Nuclear Information System (INIS)

    Jarry, G; De Marco, J J; Beifuss, U; Cagnon, C H; McNitt-Gray, M F

    2003-01-01

    The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and voxelized patient data. To accomplish this we have modified a general purpose Monte Carlo transport code (MCNP4B) to simulate the CT x-ray source and movement, and then to calculate absorbed radiation dose in desired objects. The movement of the source in either axial or spiral modes was modelled explicitly while the CT system components were modelled using published information about x-ray spectra as well as information provided by the manufacturer. Simulations were performed for single axial scans using the head and body computed tomography dose index (CTDI) polymethylmethacrylate phantoms at both central and peripheral positions for all available beam energies and slice thicknesses. For comparison, corresponding physical measurements of CTDI in phantom were made with an ion chamber. To obtain absolute dose values, simulations and measurements were performed in air at the scanner isocentre for each beam energy. To extend the verification, the CT scanner model was applied to the MIRD V model and compared with published results using similar technical factors. After verification of the model, the generalized source was simulated and applied to voxelized models of patient anatomy. The simulated and measured absolute dose data in phantom agreed to within 2% for the head phantom and within 4% for the body phantom at 120 and 140 kVp; this extends to 8% for the head and 9% for the body phantom across all available beam energies and positions. For the head phantom, the simulated and measured absolute dose data agree to within 2% across all slice thicknesses at 120 kVp. Our results in the MIRD phantom agree within 11% of all the different organ dose values

  8. Dose Rate Effects in Linear Bipolar Transistors

    Science.gov (United States)

    Johnston, Allan; Swimm, Randall; Harris, R. D.; Thorbourn, Dennis

    2011-01-01

    Dose rate effects are examined in linear bipolar transistors at high and low dose rates. At high dose rates, approximately 50% of the damage anneals at room temperature, even though these devices exhibit enhanced damage at low dose rate. The unexpected recovery of a significant fraction of the damage after tests at high dose rate requires changes in existing test standards. Tests at low temperature with a one-second radiation pulse width show that damage continues to increase for more than 3000 seconds afterward, consistent with predictions of the CTRW model for oxides with a thickness of 700 nm.

  9. Evaluation of Inhaled Versus Deposited Dose Using the Exponential Dose-Response Model for Inhalational Anthrax in Nonhuman Primate, Rabbit, and Guinea Pig.

    Science.gov (United States)

    Gutting, Bradford W; Rukhin, Andrey; Mackie, Ryan S; Marchette, David; Thran, Brandolyn

    2015-05-01

    The application of the exponential model is extended by the inclusion of new nonhuman primate (NHP), rabbit, and guinea pig dose-lethality data for inhalation anthrax. Because deposition is a critical step in the initiation of inhalation anthrax, inhaled doses may not provide the most accurate cross-species comparison. For this reason, species-specific deposition factors were derived to translate inhaled dose to deposited dose. Four NHP, three rabbit, and two guinea pig data sets were utilized. Results from species-specific pooling analysis suggested all four NHP data sets could be pooled into a single NHP data set, which was also true for the rabbit and guinea pig data sets. The three species-specific pooled data sets could not be combined into a single generic mammalian data set. For inhaled dose, NHPs were the most sensitive (relative lowest LD50) species and rabbits the least. Improved inhaled LD50 s proposed for use in risk assessment are 50,600, 102,600, and 70,800 inhaled spores for NHP, rabbit, and guinea pig, respectively. Lung deposition factors were estimated for each species using published deposition data from Bacillus spore exposures, particle deposition studies, and computer modeling. Deposition was estimated at 22%, 9%, and 30% of the inhaled dose for NHP, rabbit, and guinea pig, respectively. When the inhaled dose was adjusted to reflect deposited dose, the rabbit animal model appears the most sensitive with the guinea pig the least sensitive species. © 2014 Society for Risk Analysis.

  10. Seasonal behavior of radon decay products in indoor air and resulting radiation dose to human respiratory tract

    Directory of Open Access Journals (Sweden)

    A.M.A. Mostafa

    2015-01-01

    Full Text Available Most of radiation hazard of indoor radon is largely due to the radon progenies, which are inhaled and deposited in the human respiratory tract. It is essential to evaluate aerodynamic characteristics of the radon progenies, which are either attached or unattached to aerosol particles, because the dose is strongly dependent on the location of deposition in respiratory tract and hence on the aerodynamic characteristics of the aerosol particles. This paper presents the seasonal behavior of radon decay products in indoor air under domestic conditions at Nagoya University, Japan. A low pressure cascade impactor as an instrument for classifying aerosol sizes and imaging plate as a radiation detector have been employed to characterize the activity size distribution of short-lived radon decay products. In parallel, radon and its progenies concentrations were measured. Taking into account the progeny characteristics, the inhalation dose in the different seasons was also estimated based on a lung dose model with the structure that is related to the ICRP66 respiratory tract model. The result evident that, the highest dose 0.22 mSvy−1 was observed during the winter where the highest value of equilibrium equivalent concentration of radon (EEC and lowest value of the activity median aerodynamic diameter (AMAD were found in this season; whereas, the dose in spring appeared to be lowest 0.02 mSvy−1.

  11. Deviation from additivity in mixture toxicity: relevance of nonlinear dose-response relationships and cell line differences in genotoxicity assays with combinations of chemical mutagens and gamma-radiation.

    Science.gov (United States)

    Lutz, Werner K; Vamvakas, Spyros; Kopp-Schneider, Annette; Schlatter, Josef; Stopper, Helga

    2002-12-01

    Sublinear dose-response relationships are often seen in toxicity testing, particularly with bioassays for carcinogenicity. This is the result of a superimposition of various effects that modulate and contribute to the process of cancer formation. Examples are saturation of detoxification pathways or DNA repair with increasing dose, or regenerative hyperplasia and indirect DNA damage as a consequence of high-dose cytotoxicity and cell death. The response to a combination treatment can appear to be supra-additive, although it is in fact dose-additive along a sublinear dose-response curve for the single agents. Because environmental exposure of humans is usually in a low-dose range and deviation from linearity is less likely at the low-dose end, combination effects should be tested at the lowest observable effect levels (LOEL) of the components. This principle has been applied to combinations of genotoxic agents in various cellular models. For statistical analysis, all experiments were analyzed for deviation from additivity with an n-factor analysis of variance with an interaction term, n being the number of components tested in combination. Benzo[a]pyrene, benz[a]anthracene, and dibenz[a,c]anthracene were tested at the LOEL, separately and in combination, for the induction of revertants in the Ames test, using Salmonella typhimurium TA100 and rat liver S9 fraction. Combined treatment produced no deviation from additivity. The induction of micronuclei in vitro was investigated with ionizing radiation from a 137Cs source and ethyl methanesulfonate. Mouse lymphoma L5178Y cells revealed a significant 40% supra-additive combination effect in an experiment based on three independent replicates for controls and single and combination treatments. On the other hand, two human lymphoblastoid cell lines (TK6 and WTK1) as well as a pilot study with human primary fibroblasts from fetal lung did not show deviation from additivity. Data derived from one cell line should therefore

  12. Caffeine reversal of ethanol effects on the multiple sleep latency test, memory, and psychomotor performance.

    Science.gov (United States)

    Drake, Christopher L; Roehrs, Timothy; Turner, Lauren; Scofield, Holly M; Roth, Thomas

    2003-02-01

    Caffeine has been shown to reverse some of the performance-impairing effects of ethanol. However, it is not known whether this antagonistic effect of caffeine is mediated by a reduction in sleepiness. The present study assessed physiological alertness/sleepiness, memory, and psychomotor performance following the administration of placebo, ethanol, and caffeine+ethanol combinations. A total of 13 healthy individuals (21-35 years old) underwent four conditions presented in a Latin Square Design: placebo-placebo, ethanol (0.5 g/kg)-placebo, ethanol (0.5 g/kg)-caffeine 150 mg, and ethanol (0.5 g/kg)-caffeine 300-mg. The Multiple Sleep Latency Test (MSLT), psychomotor performance battery, memory test, and mood/sleepiness questionnaires were administered following each condition. The peak breadth ethanol concentration (BrEC) was 0.043+/-0.0197% and did not differ among the three caffeine treatments. As expected, ethanol reduced mean latency on the MSLT. The lowest caffeine dose reversed this effect and the highest dose increased mean latency (greater alertness) significantly beyond placebo levels. Ethanol also impaired psychomotor performance and memory. The 300-mg caffeine dose restored performance and memory measures to placebo levels. Although visual analog ratings of dizziness were increased by ethanol, they were not diminished by either caffeine dose. In conclusion, Low-dose caffeine prevented the sleepiness and performance impairment associated with a moderate dose of ethanol. Thus, caffeine, similar to other stimulants, can reverse the physiologically sedating effects of ethanol, although other negative effects remain.

  13. Characterization of silicates and calcium carbonates applied to high-dose dosimetry; Caracterizacao de silicatos e carbonatos de calcio aplicados a dosimetria de doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Vila, Gustavo Barreto

    2012-07-01

    The predominant isomorphous form in the biominerals studied in this work (oyster shell, coral, mother of pearl and shell) was aragonite. The appearance of the calcite phase occurred at 500 deg C at a heating rate of 10 deg {sup C}/s for all samples except for the coral sample, which was 400 deg C, independent of the heating rate. The most abundant element in the biominerals samples was Ca in the CaO form, and in the silicates (tremolite, diopside and rhodonite) Si in the SiO form. The most common trace element observed in the biominerals samples was Fe. The analyses of electron paramagnetic resonance showed lines of Mn{sup 2+} in the coral and mother-of-pearl samples before irradiation. In the case of the irradiated samples, the defects found were CO{sub 2}{sup -}, CO{sub 3}{sup 3-}, CO{sub 3}{sup -} and SO{sub 2}{sup -}, in the g range between 2.0010 and 2.0062. In the analyses by optical absorption of biominerals, transitions due to the presence of Mn in the samples were found. A thermoluminescent (TL) peak at approximately 140 deg C was found for the biominerals and at 180 deg C for silicates, which intensity depends directly on the dose. For samples exposed to different types of radiation, the TL peak occurred at lower temperatures. From the dose-response curves obtained for these materials, it was possible to determine a linear range for which their application in high dose dosimetry becomes possible. Taking into account the radiation type, among biominerals and silicates, the lowest detectable dose (40mGy) to gamma radiation was achieved for oyster shell samples using the measuring technique of optically stimulated luminescence (OSL). Using beta radiation, for diopside and tremolite samples the lowest detectable dose of 60mGy was obtained. For all samples, using the TL, OSL and thermally stimulated exoelectron emission (TSEE) techniques in alpha, beta and gamma radiation beans a good response reproducibility was obtained. Therefore, the samples characterized

  14. Linear dose response curves in fungi and tradescantia

    International Nuclear Information System (INIS)

    Unrau, P.

    1999-07-01

    strains never approaches the expected slope of predicted for two hit events. This suggests that only particular combinations of coincident LCD and DSB lesions lead, on repair, to LOH. All the evidence suggests that DNA damage induction is linear to the lowest doses. The evidence suggests that even at the lowest doses and dose rates of low LET radiation, there is a constant probability of LOH arising from repair. The effects on cancer risk of this LOH will depend upon the genotype of the individual, and further selective mechanisms which may ameliorate or intensify the effects of the original LOH event. Radiation LOH mechanisms and organismic selective screens can be tested using mice with a defined genetic back-ground, and with genes involved in DNA repair and cancer risk, inactivated or knocked out to produce 'heterozygotes'. By selecting cancers within or outside the selective screen of the immune system the effects of immunological surveillance on the risks associated with LOH of a cancer risk gene can be measured. By knocking out genes in the RAD 52 or RAD 6 pathways, the differential effects of low and high LET radiations, the effects of repair deficiencies on RBE, and dose rate effects can be measured in heterozygotes. The interest in heterozygotes arises because they are expected to be present in the population at approximately four times the square root of the frequency of homozygotes, and because in terms of Knudson's multi-step theory of cancer risk, they have already inherited the first 'hit' from their parents in the form of one abnormal cancer risk gene. Clone 02 is abnormal, but in the same way that a heterozygous carrier of a Fanconi's anemia gene would be. As 1/77 of South African Afrikaans speakers are carriers of a Fanconi's anemia mutant gene, the Clone 02 results can be extrapolated to real human populations. It would, therefore, be expected that real humans would show linear non-threshold radiation-induced LOH and potentially cancer risk. (author)

  15. Linear dose response curves in fungi and tradescantia

    Energy Technology Data Exchange (ETDEWEB)

    Unrau, P. [Atomic Energy of Canada Ltd., Chalk River, Ontario (Canada)

    1999-07-15

    slope of LOH in Clone 02 and all other strains never approaches the expected slope of predicted for two hit events. This suggests that only particular combinations of coincident LCD and DSB lesions lead, on repair, to LOH. All the evidence suggests that DNA damage induction is linear to the lowest doses. The evidence suggests that even at the lowest doses and dose rates of low LET radiation, there is a constant probability of LOH arising from repair. The effects on cancer risk of this LOH will depend upon the genotype of the individual, and further selective mechanisms which may ameliorate or intensify the effects of the original LOH event. Radiation LOH mechanisms and organismic selective screens can be tested using mice with a defined genetic back-ground, and with genes involved in DNA repair and cancer risk, inactivated or knocked out to produce 'heterozygotes'. By selecting cancers within or outside the selective screen of the immune system the effects of immunological surveillance on the risks associated with LOH of a cancer risk gene can be measured. By knocking out genes in the RAD 52 or RAD 6 pathways, the differential effects of low and high LET radiations, the effects of repair deficiencies on RBE, and dose rate effects can be measured in heterozygotes. The interest in heterozygotes arises because they are expected to be present in the population at approximately four times the square root of the frequency of homozygotes, and because in terms of Knudson's multi-step theory of cancer risk, they have already inherited the first 'hit' from their parents in the form of one abnormal cancer risk gene. Clone 02 is abnormal, but in the same way that a heterozygous carrier of a Fanconi's anemia gene would be. As 1/77 of South African Afrikaans speakers are carriers of a Fanconi's anemia mutant gene, the Clone 02 results can be extrapolated to real human populations. It would, therefore, be expected that real humans would show linear

  16. Tradeoffs between image quality and dose

    International Nuclear Information System (INIS)

    Seibert, J.A.

    2004-01-01

    Image quality takes on different perspectives and meanings when associated with the concept of as low as reasonably achievable (ALARA), which is chiefly focused on radiation dose delivered as a result of a medical imaging procedure. ALARA is important because of the increased radiosensitivity of children to ionizing radiation and the desire to keep the radiation dose low. By the same token, however, image quality is also important because of the need to provide the necessary information in a radiograph in order to make an accurate diagnosis. Thus, there are tradeoffs to be considered between image quality and radiation dose, which is the main topic of this article. ALARA does not necessarily mean the lowest radiation dose, nor, when implemented, does it result in the least desirable radiographic images. With the recent widespread implementation of digital radiographic detectors and displays, a new level of flexibility and complexity confronts the technologist, physicist, and radiologist in optimizing the pediatric radiography exam. This is due to the separation of the acquisition, display, and archiving events that were previously combined by the screen-film detector, which allows for compensation for under- and overexposures, image processing, and on-line image manipulation. As explained in the article, different concepts must be introduced for a better understanding of the tradeoffs encountered when dealing with digital radiography and ALARA. In addition, there are many instances during the image acquisition/display/interpretation process in which image quality and associated dose can be compromised. This requires continuous diligence to quality control and feedback mechanisms to verify that the goals of image quality, dose and ALARA are achieved. (orig.)

  17. The Bad Berka dose protocol: comparative results of dosimetry in peptide receptor radionuclide therapy using (177)Lu-DOTATATE, (177)Lu-DOTANOC, and (177)Lu-DOTATOC.

    Science.gov (United States)

    Schuchardt, Christiane; Kulkarni, Harshad R; Prasad, Vikas; Zachert, Carolin; Müller, Dirk; Baum, Richard P

    2013-01-01

    The objective of this study is to analyze the in vivo behavior of the (177)Lu-labeled peptides DOTATATE, DOTANOC, and DOTATOC used for peptide receptor radionuclide therapy (PRRNT) of neuroendocrine tumors (NETs), by measuring organ and tumor kinetics and by performing dosimetric calculations. Two hundred fifty-three patients (group 1) with metastasized NET who underwent PRRNT were examined. Out of these, 185 patients received (177)Lu-DOTATATE, 9 were treated with (177)Lu-DOTANOC, and 59 with (177)Lu-DOTATOC. Additionally, 25 patients receiving, in consecutive PRRNT cycles, DOTATATE followed by DOTATOC (group 2) and 3 patients receiving DOTATATE and DOTANOC (group 3) were analyzed. Dosimetric calculations (according to MIRD scheme) were performed using OLINDA software. In group 1, DOTATOC exhibited the lowest and DOTANOC the highest uptake and therefore mean absorbed dose in normal organs (whole body, kidney, and spleen). In group 2, there was a significant difference between DOTATATE and DOTATOC concerning kinetics and normal organ doses. (177)Lu-DOTATOC had the lowest uptake/dose delivered to normal organs and highest tumor-to-kidney ratio. There were no significant differences between the three peptides concerning tumor kinetics and mean absorbed tumor dose. The study demonstrates a correlation between high affinity of DOTANOC in vitro and high uptake in normal organs/whole body in vivo, resulting in a higher whole-body dose. DOTATOC exhibited the lowest uptake and dose delivered to normal tissues and the best tumor-to-kidney ratio. Due to large interpatient variability, individual dosimetry should be performed for each therapy cycle.

  18. Study of a low-dose capsule filling process by dynamic and static tests for advanced process understanding.

    Science.gov (United States)

    Stranzinger, S; Faulhammer, E; Scheibelhofer, O; Calzolari, V; Biserni, S; Paudel, A; Khinast, J G

    2018-04-05

    Precise filling of capsules with doses in the mg-range requires a good understanding of the filling process. Therefore, we investigated the various process steps of the filling process by dynamic and static mode tests. Dynamic tests refer to filling of capsules in a regular laboratory dosator filling machine. Static tests were conducted using a novel filling system developed by us. Three grades of lactose excipients were filled into size 3 capsules with different dosing chamber lengths, nozzle diameters and powder bed heights, and, in the dynamic mode, with two filling speeds (500, 3000 caps/h). The influence of the gap at the bottom of the powder container on the fill weight and variability was assessed. Different gaps resulted in a change in fill weight in all materials, although in different ways. In all cases, the fill weight of highly cohesive Lactohale 220 increased when decreasing the gap. Furthermore, experiments with the stand-alone static test tool indicated that this very challenging powder could successfully be filled without any pre-compression in the range of 5 mg-20 mg with acceptable RSDs. This finding is of great importance since for very fine lactose powders high compression ratios (dosing-chamber-length-to-powder-bed height compression ratios) may result in jamming of the piston. Moreover, it shows that the static mode setup is suitable for studying fill weight and variability. Since cohesive powders, such as Lactohale 220, are hard to fill, we investigated the impact of vibration on the process. Interestingly, we found no correlation between the reported fill weight changes in dynamic mode at 3000 cph and static mode using similar vibration. However, we could show that vibrations during sampling in the static mode dramatically reduced fill weight variability. Overall, our results indicate that by fine-tuning instrumental settings even very challenging powders can be filled with a low-dose dosator capsule filling machine. This study is a

  19. Do recommended doses of glyphosate-based herbicides affect soil invertebrates? Field and laboratory screening tests to risk assessment.

    Science.gov (United States)

    Niemeyer, Júlia Carina; de Santo, Fernanda Benedet; Guerra, Naiara; Ricardo Filho, Altair Maçaneiro; Pech, Tatiani Maria

    2018-05-01

    Despite glyphosate-based herbicides are widely used in agriculture, forestry and gardens, little is known about its effects on non-target organisms. The present work evaluated the ecotoxicity of four formulated products (Roundup ® Original, Trop ® , Zapp ® Qi 620 and Crucial ® ) on soil invertebrates. Screening ecotoxicity tests were carried out with soil and oat straw collected in a field experiment, besides laboratory-spiked soils. Screening tests included avoidance behaviour of earthworms (Eisenia andrei), collembolans (Folsomia candida) and isopods (Porcellio dilatatus) in single and multispecies tests; reproduction of collembolans (F. candida), and bait lamina in field. Non-avoidance behaviour was observed in standard tests (earthworms) in soil, neither in multispecies tests (earthworm + isopods) using oat straw, while for collembolans it occurred for the product Zapp ® Qi 620 even at the recommended dose. Reproduction of F. candida was not impaired even at high doses in laboratory-spiked soils. Feeding activity on bait lamina test was impaired in treatment corresponding to the red label product, Crucial ® . Results showed the relevance of bait lamina test on screening the impact of herbicides in the field. The findings highlight the importance of considering different formulations for the same active ingredient in risk assessment of pesticides. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Inadvertent injection of succinylcholine as an epidural test dose

    Directory of Open Access Journals (Sweden)

    Chryssa Pourzitaki

    Full Text Available Abstract Background and objectives: Epidural action of neuromuscular blocking agents could be explained under the light of their physicochemical characteristics and epidural space properties. In the literature there are few cases of accidental neuromuscular agent's epidural administration, manifesting mainly with neuromuscular blockade institution or fasciculations. Case report: We report a case of accidental succinylcholine administration as an epidural test dose, in a female patient undergoing scheduled laparotomy, under combined general and epidural anesthesia. Approximately 2 min after the succinylcholine injection the patient complained for shortness of breath, while mild fasciculations appeared in her trunk and face, managed by immediate general anesthesia institution. With the exception of a relatively longer duration of neuromuscular blockade compared with intravenous administration, no neurological or cardiovascular sequelae or other symptoms of local or systemic toxicity were observed. Conclusions: Oral administration of diazepam seems to lessen the adverse effects from accidental epidural administration of succinylcholine. The meticulous and discriminative labeling of syringes, as well as keeping persistent cautions during all anesthesia procedures remains of crucial importance.

  1. Concept for lowest emissions of a hydrogen internal combustion engine; Niedrigstemissionskonzept fuer einen wasserstoffbetriebenen Verbrennungsmotor

    Energy Technology Data Exchange (ETDEWEB)

    Fouquet, Marcel Christian Thomas

    2012-03-15

    This paper describes a concept with lowest emissions for a hydrogen internal combustion engine for passenger cars. With optimisation of the combustion concept the level of nitrogen oxide is below 90%, hydrocarbon and carbon monoxide below 99% of the SULEV target (CARB). This concept enables a potential in power density that is comparable to current supercharged combustion engines at lowest emission level without catalytic aftertreatment. Additionally with a catalytic aftertreatment system, the emission level of a current hydrogen combustion engine (mono-fuel) is lowered to a level, that this car can be labeled as air cleaning vehicle for hydrocarbons and carbon monoxide.

  2. Evaluation of patient absorbed dose in a PET-CT test

    International Nuclear Information System (INIS)

    Guerra P, F.; Mourao F, A. P.; Santana, P. C.

    2017-10-01

    Images of PET-CT has important diagnostic applications, especially in oncology. This equipment allows overlapping of functional images obtained from the administration of radionuclides and anatomical, generated by X-rays. The PET-CT technique may generate higher doses in patients due to the fact that two diagnostic modalities are used in a single examination. A whole body CT scan is performed and in sequence, a capture of the signal generated by the photons emitted is done. In this study, the absorbed and effective doses generated by the CT scan and incorporated by the administration of the radionuclide were evaluated in 19 organs. To evaluate the CT dose, 32 radiochromic film strips were correctly positioned into the anthropomorphic male phantom. The CT protocol performed was whole-body scanning and a high-resolution lung scan. This protocol is currently used in most services. The calculation of the effective dose from the injected activity in the patient was performed using the ICRP 106 Biokinetic model (ICRP 106, 2008). The activity to be injected may vary according to the patients body mass and with the sensitivity of the detector. The mass of the simulator used is 73.5 kg, then the simulation with and injected activity of 244.76 MBq was used. It was observed that 87.4% of the effective dose in examination PET/CT comes from the CT scans, being 63.8% of the whole body scan and 23.6% of high resolution lung scan. Using activity of 0.09 mCi x kg 18 F-FDG radiopharmaceutical contributes only 12.6% of the final effective dose. As a conclusion, it was observed that the dose in patients submitted to the 18 F-FDG PET-CT examination is high, being of great value efforts for its reduction, such as the use of appropriate image acquisition techniques and promoting the application of the principle of optimization of practice. (Author)

  3. Evaluation of patient absorbed dose in a PET-CT test

    Energy Technology Data Exchange (ETDEWEB)

    Guerra P, F.; Mourao F, A. P. [Federal University of Minas Gerais, Department of Nuclear Engineering, Av. Antonio Carlos 6627, CEP 31270-901, Pampulha, Belo Horizonte, Minas Gerais (Brazil); Santana, P. C., E-mail: fgpaiva92@gmail.com [Federal University of Minas Gerais, Medical School, Av. Prof. Alfredo Balena 190, CEP 30123970, Santa Efigenia, Belo Horizonte, Minas Gerais (Brazil)

    2017-10-15

    Images of PET-CT has important diagnostic applications, especially in oncology. This equipment allows overlapping of functional images obtained from the administration of radionuclides and anatomical, generated by X-rays. The PET-CT technique may generate higher doses in patients due to the fact that two diagnostic modalities are used in a single examination. A whole body CT scan is performed and in sequence, a capture of the signal generated by the photons emitted is done. In this study, the absorbed and effective doses generated by the CT scan and incorporated by the administration of the radionuclide were evaluated in 19 organs. To evaluate the CT dose, 32 radiochromic film strips were correctly positioned into the anthropomorphic male phantom. The CT protocol performed was whole-body scanning and a high-resolution lung scan. This protocol is currently used in most services. The calculation of the effective dose from the injected activity in the patient was performed using the ICRP 106 Biokinetic model (ICRP 106, 2008). The activity to be injected may vary according to the patients body mass and with the sensitivity of the detector. The mass of the simulator used is 73.5 kg, then the simulation with and injected activity of 244.76 MBq was used. It was observed that 87.4% of the effective dose in examination PET/CT comes from the CT scans, being 63.8% of the whole body scan and 23.6% of high resolution lung scan. Using activity of 0.09 mCi x kg {sup 18}F-FDG radiopharmaceutical contributes only 12.6% of the final effective dose. As a conclusion, it was observed that the dose in patients submitted to the {sup 18}F-FDG PET-CT examination is high, being of great value efforts for its reduction, such as the use of appropriate image acquisition techniques and promoting the application of the principle of optimization of practice. (Author)

  4. Dose and Spatial Effects in Long-Distance Radiation Signaling In Vivo: Implications for Abscopal Tumorigenesis

    International Nuclear Information System (INIS)

    Mancuso, Mariateresa; Giardullo, Paola; Leonardi, Simona; Pasquali, Emanuela; Casciati, Arianna; De Stefano, Ilaria; Tanori, Mirella; Pazzaglia, Simonetta; Saran, Anna

    2013-01-01

    Purpose: To investigate the dose and spatial dependence of abscopal radiation effects occurring in vivo in the mouse, along with their tumorigenic potential in the central nervous system (CNS) of a radiosensitive mouse model. Methods and Materials: Patched1 (Ptch1) +/− mice, carrying a germ-line heterozygous inactivating mutation in the Ptch1 gene and uniquely susceptible to radiation damage in neonatal cerebellum, were exposed directly to ionizing radiation (1, 2, or 3 Gy of x-rays) or treated in a variety of partial-body irradiation protocols, in which the animals' head was fully protected by suitable lead cylinders while the rest of the body was exposed to x-rays in full or in part. Apoptotic cell death was measured in directly irradiated and shielded cerebellum shortly after irradiation, and tumor development was monitored in lifetime groups. The same endpoints were measured using different shielding geometries in mice irradiated with 3 or 10 Gy of x-rays. Results: Although dose-dependent cell death was observed in off-target cerebellum for all doses and shielding conditions tested, a conspicuous lack of abscopal response for CNS tumorigenesis was evident at the lowest dose of 1 Gy. By changing the amount of exposed body volume, the shielding geometry could also significantly modulate tumorigenesis depending on dose. Conclusions: We conclude that interplay between radiation dose and exposed tissue volume plays a critical role in nontargeted effects occurring in mouse CNS under conditions relevant to humans. These findings may help understanding the mechanisms of long-range radiation signaling in harmful effects, including carcinogenesis, occurring in off-target tissues

  5. Low-Active Male Adolescents: A Dose Response to High-Intensity Interval Training.

    Science.gov (United States)

    Logan, Greig Robert Melrose; Harris, Nigel; Duncan, Scott; Plank, Lindsay D; Merien, Fabrice; Schofield, Grant

    2016-03-01

    High-intensity interval training (HIIT) is a potential alternative to traditionally recommended steady state exercise for providing health benefits in adolescents, yet its dose-response relationship in this cohort remains unclear, as does its translatability to real-world, nonclinical settings. The present study adopts a novel dose-response design to investigate the effects of undertaking 8 wk of HIIT on the cardiometabolic health of low-active male adolescents. Twenty-six male adolescents (age 16 ± 1 yr), identified as low active by nonparticipation in structured sport and physical education classes, were randomly assigned to one of five treatment groups. Corresponding with their group numbers (1-5), participants completed a number of HIIT "sets," which consisted of 4 repeated bouts of 20-s near-maximal exertion interspersed with 10-s passive recovery. Participants performed two HIIT sessions and one resistance training session each week for 8 wk. Baseline and follow-up health measures consisted of peak oxygen uptake (V˙O2peak) with an incremental ramp test to volitional exhaustion; body composition (including visceral fat mass, body fat, and lean tissue mass) with dual-energy x-ray absorptiometry; and lipid profile, glucose, insulin, and interleukin-6 from blood analysis. All health outcomes were analyzed as percentage changes, and data were modeled using a quadratic function to explore dose-response relationships. Significant improvements were observed for V˙O2peak (∼6%), body fat percentage (∼4%), visceral fat mass (∼10%), and waist circumference-to-height ratio (∼3%), but there was no clear effect of dose across groups. Low-active adolescent males performing a single HIIT set twice weekly, in addition to one resistance training session, gained meaningful improvements in fitness and body composition. Performing additional HIIT sets provided no additional improvements to those of the lowest dose in this study.

  6. Evaluation of organ doses and specific k effective dose of 64-slice CT thorax examination using an adult anthropomorphic phantom

    International Nuclear Information System (INIS)

    Hashim, S.; Karim, M.K.A.; Bakar, K.A.; Sabarudin, A.; Chin, A.W; Saripan, M.I.; Bradley, D.A.

    2016-01-01

    The magnitude of radiation dose in computed tomography (CT) depends on the scan acquisition parameters, investigated herein using an anthropomorphic phantom (RANDO®) and thermoluminescence dosimeters (TLD). Specific interest was in the organ doses resulting from CT thorax examination, the specific k coefficient for effective dose estimation for particular protocols also being determined. For measurement of doses representing five main organs (thyroid, lung, liver, esophagus and skin), TLD-100 (LiF:Mg, Ti) were inserted into selected holes in a phantom slab. Five CT thorax protocols were investigated, one routine (R1) and four that were modified protocols (R2 to R5). Organ doses were ranked from greatest to least, found to lie in the order: thyroid>skin>lung>liver>breast. The greatest dose, for thyroid at 25 mGy, was that in use of R1 while the lowest, at 8.8 mGy, was in breast tissue using R3. Effective dose (E) was estimated using three standard methods: the International Commission on Radiological Protection (ICRP)-103 recommendation (E103), the computational phantom CT-EXPO (E(CTEXPO)) method, and the dose-length product (DLP) based approach. E103 k factors were constant for all protocols, ~8% less than that of the universal k factor. Due to inconsistency in tube potential and pitch factor the k factors from CTEXPO were found to vary between 0.015 and 0.010 for protocols R3 and R5. With considerable variation between scan acquisition parameters and organ doses, optimization of practice is necessary in order to reduce patient organ dose. - Highlights: • Using TLD-100 dosimeters and a RANDO phantom 5 CT thorax protocol organ doses were assessed. • The specific k coefficient for effective dose estimation of protocols differed with approach. • Organ dose was observed to decrease in the order: thyroid>skin>lung>liver>breast. • E103 k factors were constant for all protocols, lower by ~8% compared to the universal k factor.

  7. Marked bengal pink. A dynamic test using marking doses; its value in jaundice diagnosis

    International Nuclear Information System (INIS)

    Kellershohn, C.; Desgrez, A.; Delaloye, B.

    1961-01-01

    The authors do a historic calling back of the differential study of jaundices thanks to the semi logarithmic gradients of expurgation of bromine sulphone-phthalein and thanks to the time of appearance of this material in the bile collected by duodenal tubing. They sum up likewise the foreign works which lead to take the place of this test, the outside count at the level of the head, the liver, and the abdomen after intravenous injection of a running dose of marked Rose Bengal. They specify the technical conditions of this test and report an experience which corroborate its value, its accuracy and the interest of its using in the different types of jaundices (hepatitis and obstructive types). (author) [fr

  8. γ-H2AX foci are increased in lymphocytes in vivo in young children 1 h after very low-dose X-irradiation: a pilot study

    International Nuclear Information System (INIS)

    Halm, Brunhild M.; Franke, Adrian A.; Lai, Jennifer F.; Turner, Helen C.; Brenner, David J.; Zohrabian, Vatche M.; DiMauro, Robert

    2014-01-01

    Computed tomography (CT) is an imaging modality involving ionizing radiation. The presence of γ-H2AX foci after low to moderate ionizing radiation exposure has been demonstrated; however it is unknown whether very low ionizing radiation exposure doses from CT exams can induce γ-H2AX formation in vivo in young children. To test whether very low ionizing radiation doses from CT exams can induce lymphocytic γ-H2AX foci (phosphorylated histones used as a marker of DNA damage) formation in vivo in young children. Parents of participating children signed a consent form. Blood samples from three children (ages 3-21 months) undergoing CT exams involving very low blood ionizing radiation exposure doses (blood doses of 0.22-1.22 mGy) were collected immediately before and 1 h post CT exams. Isolated lymphocytes were quantified for γ-H2AX foci by a technician blinded to the radiation status and dose of the patients. Paired t-tests and regression analyses were performed with significance levels set at P < 0.05. We observed a dose-dependent increase in γ-H2AX foci post-CT exams (P = 0.046) among the three children. Ionizing radiation exposure doses led to a linear increase of foci per cell in post-CT samples (102% between lowest and highest dose). We found a significant induction of γ-H2AX foci in lymphocytes from post-CT samples of three very young children. When possible, CT exams should be limited or avoided by possibly applying non-ionizing radiation exposure techniques such as US or MRI. (orig.)

  9. γ-H2AX foci are increased in lymphocytes in vivo in young children 1 h after very low-dose X-irradiation: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Halm, Brunhild M.; Franke, Adrian A.; Lai, Jennifer F. [University of Hawaii Cancer Center, Honolulu, HI (United States); Turner, Helen C.; Brenner, David J.; Zohrabian, Vatche M. [Columbia University Medical Center, Center for Radiological Research, New York, NY (United States); DiMauro, Robert [Kapi' olani Medical Center for Women and Children, Honolulu, HI (United States)

    2014-10-15

    Computed tomography (CT) is an imaging modality involving ionizing radiation. The presence of γ-H2AX foci after low to moderate ionizing radiation exposure has been demonstrated; however it is unknown whether very low ionizing radiation exposure doses from CT exams can induce γ-H2AX formation in vivo in young children. To test whether very low ionizing radiation doses from CT exams can induce lymphocytic γ-H2AX foci (phosphorylated histones used as a marker of DNA damage) formation in vivo in young children. Parents of participating children signed a consent form. Blood samples from three children (ages 3-21 months) undergoing CT exams involving very low blood ionizing radiation exposure doses (blood doses of 0.22-1.22 mGy) were collected immediately before and 1 h post CT exams. Isolated lymphocytes were quantified for γ-H2AX foci by a technician blinded to the radiation status and dose of the patients. Paired t-tests and regression analyses were performed with significance levels set at P < 0.05. We observed a dose-dependent increase in γ-H2AX foci post-CT exams (P = 0.046) among the three children. Ionizing radiation exposure doses led to a linear increase of foci per cell in post-CT samples (102% between lowest and highest dose). We found a significant induction of γ-H2AX foci in lymphocytes from post-CT samples of three very young children. When possible, CT exams should be limited or avoided by possibly applying non-ionizing radiation exposure techniques such as US or MRI. (orig.)

  10. Radiation dose to testes and risk of infertility from radiotherapy for rectal cancer.

    Science.gov (United States)

    Mazonakis, Michalis; Damilakis, John; Varveris, Haris; Gourtsouiannis, Nicholas

    2006-03-01

    This study aims to provide the means for testicular dose estimation from radiotherapy for rectal cancer. Rectal irradiation was simulated on a humanoid phantom using a 6 MV photon beam. The effect of field size, distance from irradiated area, wedge introduction into lateral beams, tissue thickness along the beam axis and use of gonad shields on the testicular dose was examined. Testicular dose was measured in five patients undergoing radiotherapy for rectal carcinoma. For a 4500 cGy tumour dose, testicular dose was 32-216 cGy depending upon the field dimensions and the distance from the field isocenter. The presence of wedges increased the testicular dose by a factor up to 2.2. The increase of irradiated tissue thickness increased the gonadal dose up to 40% whereas the use of the appropriate gonad shield reduced the dose by >66%. A simple method was developed to estimate testicular dose. The mean difference between the in vivo gonadal doses and the doses calculated using the proposed method was 5.8%. Testicular dose can exceed the value of 100 cGy, which permits a complete recovery of spermatogenesis. The presented data can be used to estimate the gonadal dose and the associated risk of infertility attributable to rectal irradiation.

  11. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R., E-mail: meirelesls@cdtn.br, E-mail: masl@cdtn.br, E-mail: lcmb@cdtn.br, E-mail: hrf@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  12. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    International Nuclear Information System (INIS)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R.

    2013-01-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  13. Influence of different anode/filter combination on radiation dose and image quality in digital mammography

    International Nuclear Information System (INIS)

    Liu Jie; Liu Peifang; Zhang Lianlian; Ma Wenjuan

    2013-01-01

    Objective: To explore the effect of different anode/filter combination on radiation dose and image quality in digital mammography, so as to choose optimal anode/filter combination to reduce radiation injury without scarifying image quality. Methods: Mammography accredition phantoms with the thickness from 1.6 cm to 8.6 cm were used to simulate human breast tissue. The same exposure conditions, pressure, compression thickness. and different anode/filter combination were employed under the automatic and manual exposure modes. The image kV, mAs, pressure, filter, average glandular dose (ACD), contrast to noise ratio (CNR) were recorded and the figure of merit (FOM) was calculated. SPSS 17.0 and one-way analysis of variance were used in the statistical analysis. Results: As the phantom thickness increase, the ACD values which were acquired with Mo/Mo, Mo/Rh, and W/Ag three different anode/filter combinations were increased, but CNR and FOM values were decreased, ACD, CNR, and FOM values which were acquired in the phantom with different thickness, and three different anode/filter combinations were statistically different (P=0.000, respectively). The ACD values of Mo/Mo were lowest. For 1.6 cm-2.6 cm phantom thicknesses, the FOMs of Mo/Rh were lowest, and for 3.6 cm-8.6 cm phantom thicknesses, the FOMs of W/Ag were lowest. Conclusion: Phantom thickness in 1.6 cm-2.6 cm and 3.6 cm-8.6 cm. Mo/Rh combination and W/Ag combination respectively can achieve the highest FOM, and can provide the best imaging quality with low radiation dose. (authors)

  14. Evaluation of radiation doses from radioactive drugs

    International Nuclear Information System (INIS)

    Halperin, J.A.; Grove, G.R.

    1977-01-01

    Radioactive new drugs are regulated by the Food and Drug Administration (FDA) in the United States. Before a new drug can be marketed it must have an approved New Drug Application (NDA). Clinical investigations of a radioactive new drug are carried out under a Notice of Claimed Investigational Exemption for a New Drug (IND), submitted to the FDA. In the review of the IND, radiation doses are projected on the basis of experimental data from animal models and from calculations based upon radiation characteristics, predicted biodistribution of the drug in humans, and activity to be administered. FDA physicians review anticipated doses and prevent clinical investigations in humans when the potential risk of the use of a radioactive substance outweighs the prospect of achieving beneficial results from the administration of the drug. In the evaluation of an NDA, FDA staff attempt to assure that the intended diagnostic or therapeutic effect is achievable with the lowest practicable radiation dose. Radiation doses from radioactive new drugs are evaluated by physicians within the FDA. Important radioactive new drugs are also evaluated by the Radiopharmaceuticals Advisory Committee. FDA also supports the Center for Internal Radiation Dosimetry at Oak Ridge, to provide information regarding in vivo distribution and dosimetry to critical organs and the whole body from radioactive new drugs. The process for evaluation of radiation doses from radioactive new drugs for protection against use of unnecessary radiation exposure by patients in nuclear medicine procedures, a

  15. Putting aside the LNT dilemma in the controllable dose concept

    International Nuclear Information System (INIS)

    Koblinger, Laszlo

    2000-01-01

    Recently, Professor R. Clarke, ICRP Chairman has published his proposal for a renewal of the basic radiation protection concept. The two main points of his proposed system are: (1) the term Controllable Dose is introduced, and (2) the protection philosophy is based on the individual. For practical uses terms like 'Action Level', 'Investigation Level' etc. are introduced. The outline of the new system promises a really less complex frame; no distinction between practices and interventions, unified treatment for occupational, medical and public exposures. There is, however, an inconsistency within the new system: Though linearity is not assumed, the relations between the definitions of the new terms of the system of protection and the doses assigned to them are still based on the LNT hypothesis. To avoid this discrepancy a new definition of Action Level is recommended as a conservative estimate of the lowest dose where harmful effects have ever been demonstrated. Other levels should be defined by the Action Level and Safety Factors applied on the doses. (author)

  16. Lowest instrumented vertebra selection in Lenke 3C and 6C scoliosis

    DEFF Research Database (Denmark)

    Wang, Yu; Bünger, Cody; Zhang, Yanqun

    2012-01-01

    PURPOSE: The aim of this study was to investigate whether or not post-op curve behaviour differs due to different choices of lowest instrumented vertebra (LIV) with reference to lumbar apical vertebra (LAV) in Lenke 3C and 6C scoliosis. METHODS: We reviewed all the AIS cases surgically treated...... it can yield similar correction while preserving more lumbar mobility and growth potential....

  17. People In Sub-Saharan Africa Rate Their Health And Health Care Among Lowest In World

    Science.gov (United States)

    Deaton, Angus S.; Tortora, Robert

    2017-01-01

    The health of people in sub-Saharan Africa is a major global concern. However, data are weak, and little is known about how people in the region perceive their health or their health care. We used data from the Gallup World Poll in 2012 to document sub-Saharan Africans’ perceived health status, their satisfaction with health care, their contact with medical professionals, and the priority they attach to health care. In comparison to other regions of the world, sub-Saharan Africa has the lowest ratings for well-being and the lowest satisfaction with health care. It also has the second lowest perception of personal health, after only the former Soviet Union and its satellites. HIV prevalence is positively correlated with perceived improvements in health care in countries with high prevalence. This is consistent with an improvement in at least some health care services as a result of the largely aid-funded rollout of antiretroviral treatment. Even so, sub-Saharan Africans do not prioritize health care as a matter of policy, although donors are increasingly shifting their aid efforts in sub-Saharan Africa toward health. PMID:25715657

  18. Thyroid doses and risk to paediatric patients undergoing neck CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Spampinato, Maria Vittoria; Tipnis, Sameer; Huda, Walter [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Tavernier, Joshua [Medical University of South Carolina, College of Medicine, Charleston, SC (United States)

    2015-07-15

    To estimate thyroid doses and cancer risk for paediatric patients undergoing neck computed tomography (CT). We used average CTDI{sub vol} (mGy) values from 75 paediatric neck CT examinations to estimate thyroid dose in a mathematical anthropomorphic phantom (ImPACT Patient CT Dosimetry Calculator). Patient dose was estimated by modelling the neck as mass equivalent water cylinder. A patient size correction factor was obtained using published relative dose data as a function of water cylinder size. Additional correction factors included scan length and radiation intensity variation secondary to tube-current modulation. The mean water cylinder diameter that modelled the neck was 14 ± 3.5 cm. The mathematical anthropomorphic phantom has a 16.5-cm neck, and for a constant CT exposure, would have thyroid doses that are 13-17 % lower than the average paediatric patient. CTDI{sub vol} was independent of age and sex. The average thyroid doses were 31 ± 18 mGy (males) and 34 ± 15 mGy (females). Thyroid cancer incidence risk was highest for infant females (0.2 %), lowest for teenage males (0.01 %). Estimated absorbed thyroid doses in paediatric neck CT did not significantly vary with age and gender. However, the corresponding thyroid cancer risk is determined by gender and age. (orig.)

  19. Analysis of thermal-dose response to heat

    International Nuclear Information System (INIS)

    Storm, F.; Roe, D.; Drury, B.

    1987-01-01

    The authors reasoned that if hyperthermia alone has a clinical anti-tumor effect, response should have a thermal dose relationship. The authors analyzed 100 patients with advanced cancer treated with magnetic-induction. Three methods of determining thermal dose were used: (A) t1x10, the lowest temperature sustained throughout the tumor for 30-60min during the first of ten daily treatments, which represents one usual course of ten hourly sessions; (B) t43 (equivalent minutes at 43C) which accounts for non-linear tumor heating by combining serially measured temperatures during the first treatment with a mathematical description of the time-temperature relationship for thermal inactivation or damage; (C) Ct43 (cumulative t43), which represents the t43 value multiplied by the actual number of subsequent daily treatments received. Response was defined as CR+PR+MR. The results show a statistically significant effect of heat alone for t1x10, t43, and Ct43. These analyses demonstrate a thermal-dose relationship between hyperthermia therapy and tumor response as a sole independent variable, which indicates that heat therapy has clinical anti-cancer activity

  20. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  1. Ultra-low dose CT attenuation correction for PET/CT

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  2. Dose Rate of Environmental Gamma Radiation in Java Island

    International Nuclear Information System (INIS)

    Gatot Suhariyono; Buchori; Dadong Iskandar

    2007-01-01

    The dose rate Monitoring of environmental gamma radiation at some locations in Java Island in the year 2005 / 2006 has been carried out. The dose rate measurement of gamma radiation is carried out by using the peripheral of Portable Gamma of Ray Spectrometer with detector of NaI(Tl), Merck Exploranium, Model GR-130- MINISPEC, while to determine its geographic position is used by the GPS (Global Positioning System), made in German corporation of GPS III Plus type. The division of measurement region was conducted by dividing Java Island become 66 parts with same distance, except in Jepara area that will built PLTN (Nuclear Energy Power), distance between measurement points is more closed. The results of dose rate measurement are in 66 locations in Java Island the range of (19.24 ± 4.05) nSv/hour until (150.78 ± 12.26) nSv/hour with mean (51.93 ± 36.53) nSv/h. The lowest dose rate was in location of Garut, while highest dose rate was in Ujung Lemah Abang, Jepara location. The data can be used for base line data of dose rate of environmental gamma radiation in Indonesia, specially in Java Island. The mean level of gamma radiation in Java monitoring area (0.46 mSv / year) was still lower than worldwide average effective dose rate of terrestrial gamma rays 0.5 mSv / year (report of UNSCEAR, 2000). (author)

  3. Long-term aging and loss-of-coolant accident (LOCA) testing of electrical cables

    International Nuclear Information System (INIS)

    Nelson, C.F.; Gauthier, G.; Carlin, F.

    1996-10-01

    Experiments were performed to assess the aging degradation and loss-of-coolant accident (LOCA) behavior of electrical cables subjected to long-term aging exposures. Four different cable types were tested in both the U.S. and France: (1) U.S. 2 conductor with ethylene propylene rubber (EPR) insulation and a Hypalon jacket. (2) U.S. 3 conductor with cross-linked polyethylene (XLPE) insulation and a Hypalon jacket. (3) French 3 conductor with EPR insulation and a Hypalon jacket. (4) French coaxial with polyethylene (PE) insulation and a PE jacket. The data represent up to 5 years of simultaneous aging where the cables were exposed to identical aging radiation doses at either 40 degrees C or 70 degrees C; however, the dose rate used for the aging irradiation was varied over a wide range (2-100 Gy/hr). Aging was followed by exposure to simulated French LOCA conditions. Several mechanical, electrical, and physical-chemical condition monitoring techniques were used to investigate the degradation behavior of the cables. All the cables, except for the French PE cable, performed acceptably during the aging and LOCA simulations. In general, cable degradation at a given dose was highest for the lowest dose rate, and the amount of degradation decreased as the dose rate was increased

  4. Evaluation tests of treatment planning systems concerning 3D dose calculation

    International Nuclear Information System (INIS)

    Simonian-Sauve, M.; Smart, C.

    1998-01-01

    The development of irradiation techniques in radiotherapy shows a clear tendency towards the systematic use of three-dimensional (3D) information. Great efforts are being made to set up 3D conformal radiotherapy. Consequently, in the aim of greater coherence and accuracy, 'the dosimetric tool' must also meet the requirements of 3D radiotherapy, as it plays a role in the treatment chain. To know if the treatment planning system is a '3D', '2D', or even '1D' system, one should not be satisfied with reading the technical documentation and the program algorithm description not entirely trust the constructor's assertions. It is essential to clearly and precisely evaluate the possibilities of the treatment planning system. Even if it is proved not to satisfy perfectly all the tests which would qualify it as a real 3D calculation system, the study of the test results helps to give clear explanations of the dosimetric results. Two series of test cases are proposed. The first series allows us to understand in which conditions the treatment planning system takes into account the scatter influence in a volume. The second series is designed to inform us about the capacity of the dose calculation algorithm when the medium encloses non-homogeneities. These test cases do not constitute an exhaustive 'check-list' able to tackle completely the question of 3D calculation. They are submitted as examples and should be considered as an evaluation methodology for the software implanted in the treatment planning system. (authors)

  5. Implementation of the validation testing in MPPG 5.a "Commissioning and QA of treatment planning dose calculations-megavoltage photon and electron beams".

    Science.gov (United States)

    Jacqmin, Dustin J; Bredfeldt, Jeremy S; Frigo, Sean P; Smilowitz, Jennifer B

    2017-01-01

    The AAPM Medical Physics Practice Guideline (MPPG) 5.a provides concise guidance on the commissioning and QA of beam modeling and dose calculation in radiotherapy treatment planning systems. This work discusses the implementation of the validation testing recommended in MPPG 5.a at two institutions. The two institutions worked collaboratively to create a common set of treatment fields and analysis tools to deliver and analyze the validation tests. This included the development of a novel, open-source software tool to compare scanning water tank measurements to 3D DICOM-RT Dose distributions. Dose calculation algorithms in both Pinnacle and Eclipse were tested with MPPG 5.a to validate the modeling of Varian TrueBeam linear accelerators. The validation process resulted in more than 200 water tank scans and more than 50 point measurements per institution, each of which was compared to a dose calculation from the institution's treatment planning system (TPS). Overall, the validation testing recommended in MPPG 5.a took approximately 79 person-hours for a machine with four photon and five electron energies for a single TPS. Of the 79 person-hours, 26 person-hours required time on the machine, and the remainder involved preparation and analysis. The basic photon, electron, and heterogeneity correction tests were evaluated with the tolerances in MPPG 5.a, and the tolerances were met for all tests. The MPPG 5.a evaluation criteria were used to assess the small field and IMRT/VMAT validation tests. Both institutions found the use of MPPG 5.a to be a valuable resource during the commissioning process. The validation testing in MPPG 5.a showed the strengths and limitations of the TPS models. In addition, the data collected during the validation testing is useful for routine QA of the TPS, validation of software upgrades, and commissioning of new algorithms. © 2016 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of

  6. Potentiation of omega-3 fatty acid antidepressant-like effects with low non-antidepressant doses of fluoxetine and mirtazapine.

    Science.gov (United States)

    Laino, Carlos Horacio; Fonseca, Cristina; Sterin-Speziale, Norma; Slobodianik, Nora; Reinés, Analía

    2010-12-01

    Despite the advances in psychopharmacology, the treatment of depressive disorders is still not satisfactory. Side effects and resistance to antidepressant drugs are the greatest complications during treatment. Based on recent evidence, omega-3 fatty acids may influence vulnerability and outcome in depressive disorders. The aim of this study was to further characterize the omega-3 antidepressant-like effect in rats in terms of its behavioral features in the depression model forced swimming test either alone or in combination with antidepressants fluoxetine or mirtazapine. Ultimately, we prompted to determine the lowest dose at which omega-3 fatty acids and antidepressant drugs may still represent a pharmacological advantage when employed in combined treatments. Chronic diet supplementation with omega-3 fatty acids produced concentration-dependent antidepressant-like effects in the forced swimming test displaying a behavioral profile similar to fluoxetine but different from mirtazapine. Fluoxetine or mirtazapine at antidepressant doses (10 and 20 mg/kg/day, respectively) rendered additive effects in combination with omega-3 fatty acid supplementation (720 mg/kg/day). Beneficial effects of combined treatment were also observed at sub-effective doses (1 mg/kg/day) of fluoxetine or mirtazapine, since in combination with omega-3 fatty acids (720 mg/kg/day), antidepressants potentiated omega-3 antidepressant-like effects. The antidepressant-like effects occurred in the absence of changes in brain phospholipid classes. The therapeutic approach of combining omega-3 fatty acids with low ineffective doses of antidepressants might represent benefits in the treatment of depression, especially in patients with depression resistant to conventional treatments and even may contribute to patient compliance by decreasing the magnitude of some antidepressant dose-dependent side effects. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Acute and chronic intakes of fallout radionuclides by Marshallese from nuclear weapons testing at Bikini and Enewetak and related internal radiation doses.

    Science.gov (United States)

    Simon, Steven L; Bouville, André; Melo, Dunstana; Beck, Harold L; Weinstock, Robert M

    2010-08-01

    Annual internal radiation doses resulting from both acute and chronic intakes of all important dose-contributing radionuclides occurring in fallout from nuclear weapons testing at Bikini and Enewetak from 1946 through 1958 have been estimated for the residents living on all atolls and separate reef islands of the Marshall Islands. Internal radiation absorbed doses to the tissues most at risk to cancer induction (red bone marrow, thyroid, stomach, and colon) have been estimated for representative persons of all population communities for all birth years from 1929 through 1968, and for all years of exposure from 1948 through 1970. The acute intake estimates rely on a model using, as its basis, historical urine bioassay data, for members of the Rongelap Island and Ailinginae communities as well as for Rongerik residents. The model also utilizes fallout times of arrival and radionuclide deposition densities estimated for all tests and all atolls. Acute intakes of 63 radionuclides were estimated for the populations of the 20 inhabited atolls and for the communities that were relocated during the testing years for reasons of safety and decontamination. The model used for chronic intake estimates is based on reported whole-body, urine, and blood counting data for residents of Utrik and Rongelap. Dose conversion coefficients relating intake to organ absorbed dose were developed using internationally accepted models but specifically tailored for intakes of particulate fallout by consideration of literature-based evidence to choose the most appropriate alimentary tract absorption fraction (f1) values. Dose estimates were much higher for the thyroid gland than for red marrow, stomach wall, or colon. The highest thyroid doses to adults were about 7,600 mGy for the people exposed on Rongelap; thyroid doses to adults were much lower, by a factor of 100 or more, for the people exposed on the populated atolls of Kwajalein and Majuro. The estimates of radionuclide intake and

  8. Collection and use of individual behavioral and consumption rate data to improve reconstruction of thyroid doses from nuclear weapons tests in Kazakhstan

    International Nuclear Information System (INIS)

    Drozdovitch, Vladimir; Schonfeld, Sara; Bouville, Andre; Land, Charles; Luckyanov, Nick; Simon, Steven L.; Schwerin, Michael

    2008-01-01

    Full text: Historical behavioral and consumption rate data were collected from residents of Kazakhstan exposed to nuclear weapons testing fallout using a focus group data collection strategy. These data will enable improved thyroid dose estimation in a radiation epidemiological study being carried out the U.S. National Cancer Institute. The study on the relationship of radiation exposure from weapons testing fallout and thyroid disease in a cohort of 2,994 subjects is now in a stage of improving earlier dose estimates based on individual information collected from a basic questionnaire administered to the study population in 1998. The study subjects of both Kazakh and Russian origin were exposed during childhood to radioactive fallout from nuclear weapons tests conducted at the Semipalatinsk Nuclear Test Site between 1949 and 1962. Due to the long time since exposure, a well developed strategy is necessary to encourage accurate memory recall. Limitations of the data collected in 1998 suggested the need to obtain reliable information that is tailored specific to the requirements of the dose reconstruction algorithm and to the evaluation of individual dose uncertainties. Focus group data collection in Kazakhstan in 2007 involved four 8-person focus groups (three of women and one of men) in each of four exposed settlements where thyroid disease screening was conducted in 1998. Age-specific data on relevant childhood behaviour, including time spent indoors and consumption of milk and other dairy products from cows, goats, horses, and sheep, were collected from women's groups. Men's focus groups were interviewed about construction materials of houses and schools as well as animal grazing patterns and supplemental feed to animals. Information obtained from the focus groups are being used to derive the settlement-, ethnicity-, age-, and gender-specific (where appropriate) probability density distributions on individual consumption rates of milk and dairy products

  9. Comparison of image quality and effective dose by additional filtration on digital chest tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kye Sun [Dept. of Dignostic Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Sung Chul [Dept. of Radiological Science, Gachon University, Sungnam (Korea, Republic of)

    2015-12-15

    The purpose of this study is to suggest proper additional filtration by comparisons patient dose and image quality among additional filters in digital chest tomosynthesis (DTS). We measured the effective dose, dose area product (DAP) by changing thickness of Cu, Al and Ni filter to compare image quality by CD curve and SNR, CNR. Cu, Al and Ni exposure dose were similar thickness 0.3 mm, 3 mm and 0.3 mm respectively. The exposure dose using filter was decreased average about 33.1% than non filter. The DAP value of 0.3 mm Ni were decreased 72.9% compared to non filter and the lowest dose among 3 filter. The effective dose of 0.3 mm Ni were decreased 48% compared to 0.102 mSv effective dose of non filter. At the result of comparison of image quality through CD curve there were similar aspect graph among Cu, Al and Ni. SNR was decreased average 19.07%, CNR was average decreased 18.17% using 3 filters. In conclusion, Ni filtration was considered to be most suitable when considered comprehensive thickness, character, sort of filter, dose reduction and image quality evaluation in DTS.

  10. Estimation and comparison of effective dose (E) in standard chest CT by organ dose measurements and dose-length-product methods and assessment of the influence of CT tube potential (energy dependency) on effective dose in a dual-source CT

    International Nuclear Information System (INIS)

    Paul, Jijo; Banckwitz, Rosemarie; Krauss, Bernhard; Vogl, Thomas J.; Maentele, Werner; Bauer, Ralf W.

    2012-01-01

    Highlights: ► The dual-energy protocol delivers the lowest effective dose of the investigated protocols for standard chest CT examinations, thus enabling functional imaging (like dual-energy perfusion) and can produce weighted images without dose penalty. ► The high-pitch protocol goes along with a 16% increase in dose compared to the standard 120 kV protocol and thus should preferably be used in pediatric, acute care settings (e.g. pulmonary embolism, aortic dissection and the like) or restless patients. ► The difference in effective dose estimates between ICRP 60 and 103 is minimal. ► Tube potential definitely has an effect on estimates of effective dose. - Abstract: Purpose: To determine effective dose (E) during standard chest CT using an organ dose-based and a dose-length-product-based (DLP) approach for four different scan protocols including high-pitch and dual-energy in a dual-source CT scanner of the second generation. Materials and methods: Organ doses were measured with thermo luminescence dosimeters (TLD) in an anthropomorphic male adult phantom. Further, DLP-based dose estimates were performed by using the standard 0.014 mSv/mGycm conversion coefficient k. Examinations were performed on a dual-source CT system (Somatom Definition Flash, Siemens). Four scan protocols were investigated: (1) single-source 120 kV, (2) single-source 100 kV, (3) high-pitch 120 kV, and (4) dual-energy with 100/Sn140 kV with equivalent CTDIvol and no automated tube current modulation. E was then determined following recommendations of ICRP publication 103 and 60 and specific k values were derived. Results: DLP-based estimates differed by 4.5–16.56% and 5.2–15.8% relatively to ICRP 60 and 103, respectively. The derived k factors calculated from TLD measurements were 0.0148, 0.015, 0.0166, and 0.0148 for protocol 1, 2, 3 and 4, respectively. Effective dose estimations by ICRP 103 and 60 for single-energy and dual-energy protocols show a difference of less than 0.04 m

  11. Around Semipalatinsk nuclear test site: progress of dose estimations relevant to the consequences of nuclear tests (a summary of 3rd Dosimetry Workshop on the Semipalatinsk nuclear test site area, RIRBM, Hiroshima University, Hiroshima, 9-11 of March, 2005).

    Science.gov (United States)

    Stepanenko, Valeriy F; Hoshi, Masaharu; Bailiff, Ian K; Ivannikov, Alexander I; Toyoda, Shin; Yamamoto, Masayoshi; Simon, Steven L; Matsuo, Masatsugu; Kawano, Noriyuki; Zhumadilov, Zhaxybay; Sasaki, Masao S; Rosenson, Rafail I; Apsalikov, Kazbek N

    2006-02-01

    The paper is an analytical overview of the main results presented at the 3rd Dosimetry Workshop in Hiroshima(9-11 of March 2005), where different aspects of the dose reconstruction around the Semipalatinsk nuclear test site(SNTS) were discussed and summarized. The results of the international intercomparison of the retrospective luminescence dosimetry(RLD) method for Dolon' village(Kazakhstan) were presented at the Workshop and good concurrence between dose estimations by different laboratories from 6 countries (Japan, Russia, USA, Germany, Finland and UK) was pointed out. The accumulated dose values in brick for a common depth of 10mm depth obtained independently by all participating laboratories were in good agreement for all four brick samples from Dolon' village, Kazakhstan, with the average value of the local gamma dose due to fallout (near the sampling locations) being about 220 mGy(background dose has been subtracted).Furthermore, using a conversion factor of about 2 to obtain the free-in-air dose, a value of local dose approximately 440 mGy is obtained, which supports the results of external dose calculations for Dolon': recently published soil contamination data, archive information and new models were used for refining dose calculations and the external dose in air for Dolon village was estimated to be about 500 mGy. The results of electron spin resonance(ESR) dosimetry with tooth enamel have demonstrated the notable progress in application of ESR dosimetry to the problems of dose reconstruction around the Semipalatinsk nuclear test site. At the present moment, dose estimates by the ESR method have become more consistent with calculated values and with retrospective luminescence dosimetry data, but differences between ESR dose estimates and RLD/calculation data were noted. For example mean ESR dose for eligible tooth samples from Dolon' village was estimated to be about 140 mGy(above background dose), which is less than dose values obtained by RLD and

  12. Solar Variability and the Near-Earth Environment: Mining Enhanced Low Dose Rate Sensitivity Data From the Microelectronics and Photonics Test Bed Space Experiment

    Science.gov (United States)

    Turflinger, T.; Schmeichel, W.; Krieg, J.; Titus, J.; Campbell, A.; Reeves, M.; Marshall (P.); Hardage, Donna (Technical Monitor)

    2004-01-01

    This effort is a detailed analysis of existing microelectronics and photonics test bed satellite data from one experiment, the bipolar test board, looking to improve our understanding of the enhanced low dose rate sensitivity (ELDRS) phenomenon. Over the past several years, extensive total dose irradiations of bipolar devices have demonstrated that many of these devices exhibited ELDRS. In sensitive bipolar transistors, ELDRS produced enhanced degradation of base current, resulting in enhanced gain degradation at dose rates 1 rd(Si)/s. This Technical Publication provides updated information about the test devices, the in-flight experiment, and both flight-and ground-based observations. Flight data are presented for the past 5 yr of the mission. These data are compared to ground-based data taken on devices from the same date code lots. Information about temperature fluctuations, power shutdowns, and other variables encountered during the space flight are documented.

  13. Award of Construction Contracts: Public Institutions' Authority to Select the Lowest Responsible Bidder.

    Science.gov (United States)

    Cole, Elsa Kircher; Goldblatt, Steven M.

    1989-01-01

    The article describes the responsibilities of public colleges and universities to award construction contracts to the lowest responsible bidder; discusses the purpose of bid statutes; and lists the factors institutions should consider in determining a bidder's responsibility. Also covered are the standard of review and due process rights of the…

  14. Efficacy and safety of alirocumab in patients with hypercholesterolemia not adequately controlled with non-statin lipid-lowering therapy or the lowest strength of statin: ODYSSEY NIPPON study design and rationale.

    Science.gov (United States)

    Teramoto, Tamio; Kondo, Akira; Kiyosue, Arihiro; Harada-Shiba, Mariko; Ishigaki, Yasushi; Tobita, Kimimasa; Kawabata, Yumiko; Ozaki, Asuka; Baccara-Dinet, Marie T; Sata, Masataka

    2017-06-17

    Statins are generally well-tolerated and serious side effects are infrequent, but some patients experience adverse events and reduce their statin dose or discontinue treatment altogether. Alirocumab is a highly specific, fully human monoclonal antibody to proprotein convertase subtilisin/kexin type 9 (PCSK9), which can produce substantial and sustained reductions of low-density lipoprotein cholesterol (LDL-C). The randomized, double-blind, placebo-controlled, parallel-group, phase 3 ODYSSEY NIPPON study will explore alirocumab 150 mg every 4 weeks (Q4W) in 163 Japanese patients with hypercholesterolemia who are on the lowest-strength dose of atorvastatin (5 mg/day) or are receiving a non-statin lipid-lowering therapy (LLT) (fenofibrate, bezafibrate, ezetimibe, or diet therapy alone). Hypercholesterolemia is defined as LDL-C ≥ 100 mg/dL (2.6 mmol/L) in patients with heterozygous familial hypercholesterolemia or non-familial hypercholesterolemia with a history of documented coronary heart disease, or ≥120 mg/dL (3.1 mmol/L) in patients with non-familial hypercholesterolemia classified as primary prevention category III (i.e. high-risk patients). During the 12-week double-blind treatment period, patients will be randomized (1:1:1) to receive alirocumab subcutaneously (SC) 150 mg Q4W alternating with placebo for alirocumab Q4W, or alirocumab 150 mg SC every 2 weeks (Q2W), or SC placebo Q2W. The primary efficacy endpoint is the percentage change in calculated LDL-C from baseline to week 12. The long-term safety and tolerability of alirocumab will also be investigated. The ODYSSEY NIPPON study will provide insights into the efficacy and safety of alirocumab 150 mg Q4W or 150 mg Q2W among Japanese patients with hypercholesterolemia who are on the lowest-strength dose of atorvastatin, or are receiving a non-statin LLT (including diet therapy alone). ClinicalTrials.gov number: NCT02584504.

  15. The ToxBank Data Warehouse: Supporting the Replacement of In Vivo Repeated Dose Systemic Toxicity Testing.

    Science.gov (United States)

    Kohonen, Pekka; Benfenati, Emilio; Bower, David; Ceder, Rebecca; Crump, Michael; Cross, Kevin; Grafström, Roland C; Healy, Lyn; Helma, Christoph; Jeliazkova, Nina; Jeliazkov, Vedrin; Maggioni, Silvia; Miller, Scott; Myatt, Glenn; Rautenberg, Michael; Stacey, Glyn; Willighagen, Egon; Wiseman, Jeff; Hardy, Barry

    2013-01-01

    The aim of the SEURAT-1 (Safety Evaluation Ultimately Replacing Animal Testing-1) research cluster, comprised of seven EU FP7 Health projects co-financed by Cosmetics Europe, is to generate a proof-of-concept to show how the latest technologies, systems toxicology and toxicogenomics can be combined to deliver a test replacement for repeated dose systemic toxicity testing on animals. The SEURAT-1 strategy is to adopt a mode-of-action framework to describe repeated dose toxicity, combining in vitro and in silico methods to derive predictions of in vivo toxicity responses. ToxBank is the cross-cluster infrastructure project whose activities include the development of a data warehouse to provide a web-accessible shared repository of research data and protocols, a physical compounds repository, reference or "gold compounds" for use across the cluster (available via wiki.toxbank.net), and a reference resource for biomaterials. Core technologies used in the data warehouse include the ISA-Tab universal data exchange format, REpresentational State Transfer (REST) web services, the W3C Resource Description Framework (RDF) and the OpenTox standards. We describe the design of the data warehouse based on cluster requirements, the implementation based on open standards, and finally the underlying concepts and initial results of a data analysis utilizing public data related to the gold compounds. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Isotoxic dose escalation in the treatment of lung cancer by means of heterogeneous dose distributions in the presence of respiratory motion

    DEFF Research Database (Denmark)

    Baker, Mariwan; Nielsen, Morten; Hansen, Olfred

    2011-01-01

    To test, in the presence of intrafractional respiration movement, a margin recipe valid for a homogeneous and conformal dose distribution and to test whether the use of smaller margins combined with heterogeneous dose distributions allows an isotoxic dose escalation when respiratory motion...

  17. Sixty women a day examined with world-unique mammography system from Sectra. Breast disease centre in Sweden offers lowest radiation dose in the world

    CERN Multimedia

    2003-01-01

    "Sectra's digital mammography system, Sectra MicroDose Mammography(TM), has been used to examine more than 1,500 women in the Helsingborg Hospital mammography screening program. This was accomplished in the record time of two months in clinical operation. The system is now being used to examine more than sixty women every day" (1 page).

  18. Single-dose and fractionated irradiation of four human lung cancer cell lines in vitro

    International Nuclear Information System (INIS)

    Brodin, O.; Lennartsson, L.; Nilsson, S.

    1991-01-01

    Four established human lung cancer cell lines were exposed to single-dose irradiation. The survival curves of 2 small cell lung carcinomas (SCLC) were characterized by a limited capacity for repair with small and moderate shoulders with extrapolation numbers (n) of 1.05 and 1.60 respectively. Two non-small cell lung carcinoma (NSCLC) cell lines, one squamous cell (SQCLC) and one large cell (LCLC) had large shoulders with n-values of 73 and 15 respectively. The radiosensitivity when measured as D 0 did not, however, differ as much from cell line to cell line, with values from 1.22 to 1.65. The surviving fraction after 2 Gy (SF2) was 0.24 and 0.42 respectively in the SCLC cell lines and 0.90 and 0.88 respectively in the NSCLC cell lines. Fractionated irradiation delivered according to 3 different schedules was also investigated. All the schedules delivered a total dose of 10 Gy in 5 days and were applied in 1, 2 and 5 Gy dose fractions respectively. Survival followed the pattern found after single-dose irradiation; it was lowest in the SCLC cell line with the lowest SF and highest in the two NSCLC cell lines. In the SCLC cell lines all schedules were approximately equally efficient. In the LCLC and in the SQCLC cell lines, the 5 Gy schedule killed more cells than the 1 and 2 Gy schedules. The results indicate that the size of the shoulder of the survival curve is essential when choosing the most tumoricidal fractionation schedule. (orig.)

  19. High-dose irradiation of food

    International Nuclear Information System (INIS)

    Diehl, J.F.

    1999-01-01

    Studies performed on behalf of the International Project on Food Irradiation in the period from 1971 until 1980 resulted in the concluding statement that ''.the irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard; hence, toxicological testing of foods so treated is no longer required.'' Since then, licenses for food irradiation have been restricted to this maximum dose in any country applying this technology. Further testing programmes have been carried out investigating the wholesomeness or hazards of high-dose irradiation, but there has been little demand so far by the food industry for licensing of high-dose irradiation, as there is only a small range of products whose irradiation at higher doses offers advantages for given, intended use. These include eg. spices, dried herbs, meat products in flexible pouch packagings for astronauts, or patients with immune deficiencies. (orig./CB) [de

  20. COMPARISON OF THE PERIPHERAL DOSES FROM DIFFERENT IMRT TECHNIQUES FOR PEDIATRIC HEAD AND NECK RADIATION THERAPY.

    Science.gov (United States)

    Toyota, Masahiko; Saigo, Yasumasa; Higuchi, Kenta; Fujimura, Takuya; Koriyama, Chihaya; Yoshiura, Takashi; Akiba, Suminori

    2017-11-01

    Intensity-modulated radiation therapy (IMRT) can deliver high and homogeneous doses to the target area while limiting doses to organs at risk. We used a pediatric phantom to simulate the treatment of a head and neck tumor in a child. The peripheral doses were examined for three different IMRT techniques [dynamic multileaf collimator (DMLC), segmental multileaf collimator (SMLC) and volumetric modulated arc therapy (VMAT)]. Peripheral doses were evaluated taking thyroid, breast, ovary and testis as the points of interest. Doses were determined using a radio-photoluminescence glass dosemeter, and the COMPASS system was used for three-dimensional dose evaluation. VMAT achieved the lowest peripheral doses because it had the highest monitor unit efficiency. However, doses in the vicinity of the irradiated field, i.e. the thyroid, could be relatively high, depending on the VMAT collimator angle. DMLC and SMLC had a large area of relatively high peripheral doses in the breast region. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Atopy patch tests in young adult patients with atopic dermatitis and controls: dose-response relationship, objective reading, reproducibility and clinical interpretation.

    Science.gov (United States)

    Bygum, Anette; Mortz, Charlotte Gotthard; Andersen, Klaus Ejner

    2003-01-01

    The clinical interpretation and reproducibility of atopy patch tests was studied in 23 selected young adult patients with atopic dermatitis and 25 healthy controls using standard inhalant allergens. Non-invasive measurements were used for objective assessment of test reactions and the participants were retested after 6 weeks. Ten of 19 (53%) evaluable patients with atopic dermatitis had at least one positive atopy patch test. However, there was no clear clinical relevance of the atopy patch test results when related to patient history and distribution of dermatitis. Reproducible and dose-dependent results were obtained with Dermatophagoides pteronyssinus, grass and cat with a reproducibility rate of 0.69 to 0.81 in patients and 0.60-0.96 in controls. A unique finding was a significant positive correlation between a positive atopy patch test, allergen dose and increase in transepidermal water loss and erythema, while measurement of capacitance did not distinguish between positive and negative reactions. The results of the present study do not support the routine use of atopy patch tests in the evaluation of adult patients with atopic dermatitis.

  2. Impact of the spinal cord position uncertainty on the dose received during head and neck helical tomotherapy

    International Nuclear Information System (INIS)

    Piotrowski, Tomasz; Kazmierska, Joanna; Sokolowski, Adam; Skorska, Malgorzata; Jodda, Agata; Ryczkowski, Adam; Cholewinski, Witold; Bak, Bartosz

    2013-01-01

    The study aims to establish the optimal planning risk volume (PRV) to the spinal cord (SC) for oropharyngeal cancer patients during adaptive radiation therapy with concurrent chemotherapy. Geometrical uncertainties of the SC were evaluated. Differences between planned and delivered maximum doses to each part of the SC were established for every fraction dose and for cumulative dose. Maximum doses were evaluated as a dose received in 0.5 and 1cm3 of the analysed part of the SC defined as C1–C2, C3–C4, C5–C6 and C7–Th1 where Cn was a n-th cervical vertebra (n=1, … , 7) and Th1 was the first thoracic vertebra. Finally, relations between dose differences and geometrical uncertainties were analysed using a relative risk (RR) and the importance of the PRV dose gradient to establish an optimal PRV for the SC. Prospective study based on the 875 observations from 25 oropharyngeal cancer patients was performed. The C1-C2 part of the SC is most exposed to risk of overdosage during chemoradiation for patients with oropharyngeal cancer due to its proximity to the clinical target volume (CTV). Doses received by other parts of the SC are smaller, with the lowest dose delivered to C7–Th1. For the C1–C2, delivered dose was higher than planned dose by 11%, while for the C7–Th1, this difference was smaller than 7%. The lowest movement of individual parts of the SC were detected for the C1–C2 and the highest for the C7–Th1. The standard deviations of the mean shift ranged respectively from 0.9 to 1.4mm and from 1.3 to 2.9mm. For each part of the SC delivered dose was smaller than planned dose to the PRV (RR<1). Our study showed that for chemoradiation of oropharyngeal cancer, using daily image guidance and proper plan adaptation scheme, the current PRV margin for the SC could be reduced to 4mm.

  3. Structure of the lowest excited 0/sup +/ rotational band of /sup 16/O

    Energy Technology Data Exchange (ETDEWEB)

    Ikebata, Yasuhiko; Suekane, Shota

    1983-10-01

    The structure of the lowest excited 0/sup +/ rotational band is investigated by using the extended Nilsson model wave functions with angular momentum projection and the B1 interaction, two-body LS-force of the Skyrme type and the Coulomb interaction. The results obtained show good agreement with energy interval in this band.

  4. The Dose Response Relationship for Radiation Carcinogenesis

    Science.gov (United States)

    Hall, Eric

    2008-03-01

    Recent surveys show that the collective population radiation dose from medical procedures in the U.S. has increased by 750% in the past two decades. It would be impossible to imagine the practice of medicine today without diagnostic and therapeutic radiology, but nevertheless the widespread and rapidly increasing use of a modality which is a known human carcinogen is a cause for concern. To assess the magnitude of the problem it is necessary to establish the shape of the dose response relationship for radiation carcinogenesis. Information on radiation carcinogenesis comes from the A-bomb survivors, from occupationally exposed individuals and from radiotherapy patients. The A-bomb survivor data indicates a linear relationship between dose and the risk of solid cancers up to a dose of about 2.5 Sv. The lowest dose at which there is a significant excess cancer risk is debatable, but it would appear to be between 40 and 100 mSv. Data from the occupation exposure of nuclear workers shows an excess cancer risk at an average dose of 19.4 mSv. At the other end of the dose scale, data on second cancers in radiotherapy patients indicates that cancer risk does not continue to rise as a linear function of dose, but tends towards a plateau of 40 to 60 Gy, delivered in a fractionated regime. These data can be used to estimate the impact of diagnostic radiology at the low dose end of the dose response relationship, and the impact of new radiotherapy modalities at the high end of the dose response relationship. In the case of diagnostic radiology about 90% of the collective population dose comes from procedures (principally CT scans) which involve doses at which there is credible evidence of an excess cancer incidence. While the risk to the individual is small and justified in a symptomatic patient, the same is not true of some screening procedures is asymptomatic individuals, and in any case the huge number of procedures must add up to a potential public health problem. In the

  5. Projection-operator calculations of the lowest e--He resonance

    International Nuclear Information System (INIS)

    Berk, A.; Bhatia, A.K.; Junker, B.R.; Temkin, A.

    1986-01-01

    Results for the lowest (Schulz) autodetaching state of He - [1s(2s) 2 ] are reported. The calculation utilizes the full projection-operator formalism as explicitly developed by Temkin and Bhatia [Phys. Rev. A 31, 1259 (1985)]. Eigenvalues, scrE = , are calculated using projection operators Q depending on increasingly elaborate target wave functions going up to a 10-term Hylleraas-form, and a configuration-interaction total wave function Phi of 40 configurations. Results are well converged, but our best value is --0.13 eV above the experimental position at 19.37 eV. We conclude that the shift (Δ) in the Feshbach formalism gives a large contribution (relative to the width) to the position E/sub r/ ( = scrE+Δ). An appendix is devoted to the evaluation of the most complicated type of three-center integral involved in the calculation

  6. Intravenous contrast medium administration at 128 multidetector row CT pulmonary angiography: Bolus tracking versus test bolus and the implications for diagnostic quality and effective dose

    International Nuclear Information System (INIS)

    Rodrigues, J.C.L.; Mathias, H.; Negus, I.S.; Manghat, N.E.; Hamilton, M.C.K.

    2012-01-01

    Aim: To investigate the effects of a test bolus protocol contrast medium administration on diagnostic image quality in computed tomography pulmonary angiography (CTPA). Materials and methods: Fifty patients referred for exclusion of pulmonary embolism underwent CTPA using a test bolus protocol CTPA at 120 kVp and were compared with 50 patients undergoing CTPA using a standard bolus-tracking protocol at 120 kVp, via assessment of attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) seen in the pulmonary arteries (PAs). An additional group of 10 non-obese patients who underwent CTPA using a test bolus protocol performed at 100 kVp were also analysed. Mean effective dose was calculated from the dose–length product, using standard conversion factors. Results: The test bolus protocol showed significantly higher attenuation, SNR, and CNR in the pulmonary vasculature down to the segmental level compared to bolus-tracking CTPA (p < 0.0001). There was no significant difference in effective dose between the test bolus and bolus tracking cohorts. The additional group of test bolus CTPA examinations performed at 100 kVp had a significantly reduced effective dose in comparison to both test bolus CTPA at 120 kVp and bolus-tracking CTPA at 120 kVp (p < 0.005) yet maintained mean PA attenuation to segmental level significantly better than bolus-tracking CTPA performed at 120 kVp and comparable to the test bolus cohort performed at 120 kVp. Conclusion: Test bolus contrast administration should be used as an optimal protocol. Performing test bolus CTPA at 100 kVp, as opposed to 120 kVp, significantly reduces dose without compromising PA attenuation in non-obese subjects.

  7. Benchmarking pediatric cranial CT protocols using a dose tracking software system: a multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Bondt, Timo de; Parizel, Paul M. [Antwerp University Hospital and University of Antwerp, Department of Radiology, Antwerp (Belgium); Mulkens, Tom [H. Hart Hospital, Department of Radiology, Lier (Belgium); Zanca, Federica [GE Healthcare, DoseWatch, Buc (France); KU Leuven, Imaging and Pathology Department, Leuven (Belgium); Pyfferoen, Lotte; Casselman, Jan W. [AZ St. Jan Brugge-Oostende AV Hospital, Department of Radiology, Brugge (Belgium)

    2017-02-15

    To benchmark regional standard practice for paediatric cranial CT-procedures in terms of radiation dose and acquisition parameters. Paediatric cranial CT-data were retrospectively collected during a 1-year period, in 3 different hospitals of the same country. A dose tracking system was used to automatically gather information. Dose (CTDI and DLP), scan length, amount of retakes and demographic data were stratified by age and clinical indication; appropriate use of child-specific protocols was assessed. In total, 296 paediatric cranial CT-procedures were collected. Although the median dose of each hospital was below national and international diagnostic reference level (DRL) for all age categories, statistically significant (p-value < 0.001) dose differences among hospitals were observed. The hospital with lowest dose levels showed smallest dose variability and used age-stratified protocols for standardizing paediatric head exams. Erroneous selection of adult protocols for children still occurred, mostly in the oldest age-group. Even though all hospitals complied with national and international DRLs, dose tracking and benchmarking showed that further dose optimization and standardization is possible by using age-stratified protocols for paediatric cranial CT. Moreover, having a dose tracking system revealed that adult protocols are still applied for paediatric CT, a practice that must be avoided. (orig.)

  8. CT patterns of fungal pulmonary infections of the lung: Comparison of standard-dose and simulated low-dose CT

    International Nuclear Information System (INIS)

    Christe, Andreas; Lin, Margaret C.; Yen, Andrew C.; Hallett, Rich L.; Roychoudhury, Kingshuk; Schmitzberger, Florian; Fleischmann, Dominik; Leung, Ann N.; Rubin, Geoffry D.; Vock, Peter; Roos, Justus E.

    2012-01-01

    Purpose: To assess the effect of radiation dose reduction on the appearance and visual quantification of specific CT patterns of fungal infection in immuno-compromised patients. Materials and methods: Raw data of thoracic CT scans (64 × 0.75 mm, 120 kVp, 300 reference mAs) from 41 consecutive patients with clinical suspicion of pulmonary fungal infection were collected. In 32 patients fungal infection could be proven (median age of 55.5 years, range 35–83). A total of 267 cuboids showing CT patterns of fungal infection and 27 cubes having no disease were reconstructed at the original and 6 simulated tube currents of 100, 40, 30, 20, 10, and 5 reference mAs. Eight specific fungal CT patterns were analyzed by three radiologists: 76 ground glass opacities, 42 ground glass nodules, 51 mixed, part solid, part ground glass nodules, 36 solid nodules, 5 lobulated nodules, 6 spiculated nodules, 14 cavitary nodules, and 37 foci of air-space disease. The standard of reference was a consensus subjective interpretation by experts whom were not readers in the study. Results: The mean sensitivity and standard deviation for detecting pathological cuboids/disease using standard dose CT was 0.91 ± 0.07. Decreasing dose did not affect sensitivity significantly until the lowest dose level of 5 mAs (0.87 ± 0.10, p = 0.012). Nodular pattern discrimination was impaired below the dose level of 30 reference mAs: specificity for fungal ‘mixed nodules’ decreased significantly at 20, 10 and 5 reference mAs (p < 0.05). At lower dose levels, classification drifted from ‘solid’ to ‘mixed nodule’, although no lesion was missed. Conclusion: Our simulation data suggest that tube current levels can be reduced from 300 to 30 reference mAs without impairing the diagnostic information of specific CT patterns of pulmonary fungal infections

  9. Variation in radiation doses in paediatric cardiac catheterisation procedures

    International Nuclear Information System (INIS)

    Al-Haj, A. N.; Lobriguito, A. M.; Rafeh, W.

    2008-01-01

    Paediatric cardiac catheterisation involves diagnostic and therapeutic procedures that range from simple to complex and can subject paediatric patients to varying radiation doses. The study aims to determine the variation in entrance doses in patients in terms of dose-area product (DAP) values and to investigate the methods for optimising radiation protection. A total of 190 paediatric patients belonging to age groups 0, 1, 5 and 10 y who underwent diagnostic and six selected therapeutic procedures at King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia) were included in the study. Therapeutic procedures include coarctation (COA), patent ductus arteriosus (PDA), radiofrequency ablation, pulmonary, embolisation and septostomy. Fluoroscopy and cine radiography were used in all procedures. Patient demography (weight, age, gender and height), radiographic technique factors, fluoroscopy and cine time, frame rate, and DAP values were taken from patients records. Effective doses for each procedure were estimated from the DAP values. The mean DAP per procedure were analysed for correlation with patient equivalent cylindrical diameter, weight, fluoroscopy time and number of frames. Factors influencing the variation in doses were investigated. Initial results show that PDA occlusion has the highest mean DAP value of 23.21 Gy-cm 2 , while the diagnostic and septostomy procedures have the lowest value of 7.77 and 6.95 Gy-cm 2 , respectively. (authors)

  10. Millimeter-wave and Submillimeter-wave Spectra of Aminoacetonitrile in the Three Lowest Vibrational Excited States

    Energy Technology Data Exchange (ETDEWEB)

    Esposti, Claudio Degli; Dore, Luca; Melosso, Mattia [Dipartimento di Chimica “Giacomo Ciamician”, Università di Bologna, via Selmi 2, I-40126 Bologna (Italy); Kobayashi, Kaori [Department of Physics, Faculty of Science, University of Toyama, 3190 Gofuku, Toyama 930-8555 (Japan); Fujita, Chiho; Ozeki, Hiroyuki, E-mail: ozeki@env.sci.toho-u.ac.jp [Department of Environmental Science, Faculty of Science, Toho University, 2-2-1 Miyama, Funabashi, 274-8510 (Japan)

    2017-06-01

    It is important to study possible precursors of amino acids such as glycine to enable future searches in interstellar space. Aminoacetonitrile (NH{sub 2}CH{sub 2}CN) is one of the most feasible molecules for this purpose. This molecule was already detected toward Sgr B2(N). Aminoacetonitrile has a few low-lying vibrational excited states, and transitions within these states may be found in space. In this study, the pure-rotational transitions in the three lowest vibrational states in the 80–450 GHz range have been assigned and analyzed. It was found to be very important to include Coriolis coupling between the two lowest vibrational fundamentals, while the third one was unperturbed. The partition function was evaluated considering these new results.

  11. Repeated Intramuscular-dose Toxicity Test of Water-soluble Carthami Flos (WCF Pharmacopuncture in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Yoo-min Choi

    2015-03-01

    Full Text Available Objectives: Water-soluble carthami flos (WCF is a new mixture of Carthami flos (CF pharmacopuncture. We conducted a 4-week toxicity test of repeated intramuscular injections of WCF in Sprague-Dawley rats. Methods: Forty male and 40 female rats were divided into 4 groups of 10 male and 10 female SD rats: The control group received 0.5 mL/animal/day of normal saline whereas the three experimental groups received WCF at doses of 0.125, 0.25, and 0.5 mL/animal/day, respectively. For 4 weeks, the solutions were injected into the femoral muscle of the rats alternating from side to side. Clinical signs, body weights, and food consumption were observed; opthalmological examinations and urinalyses were performed. On day 29, blood samples were taken for hematological and clinical chemistry analyses. Then, necropsy was conducted in all animals to observe weights and external and histopathological changes in the bodily organs. All data were tested using a statistical analysis system (SAS. Results: No deaths were observed. Temporary irregular respiration was observed in male rats of the experimental group for the first 10 days. Body weights, food consumptions, opthalmological examinations, urinalyses, clinical chemistry analyses, organ weights and necropsy produced no findings with toxicological meaning. In the hematological analysis, delay of prothrombin time (PT was observed in male rats of the 0.25- and the 0.5-mL/animal/day groups. In the histopathological test, a dose-dependent inflammatory cell infiltration into the fascia and panniculitis in perimuscular tissues was observed in all animals of the experimental groups. However, those symptoms were limited to local injection points. No toxicological meanings, except localized changes, were noted. Conclusion: WCF solution has no significant toxicological meaning, but does produce localized symptoms. No observed adverse effect level (NOAEL of WCF in male and female rats is expected for doses over 0.5 mL/animal/day.

  12. Dose optimisation for intraoperative cone-beam flat-detector CT in paediatric spinal surgery

    International Nuclear Information System (INIS)

    Petersen, Asger Greval; Eiskjaer, Soeren; Kaspersen, Jon

    2012-01-01

    During surgery for spinal deformities, accurate placement of pedicle screws may be guided by intraoperative cone-beam flat-detector CT. The purpose of this study was to identify appropriate paediatric imaging protocols aiming to reduce the radiation dose in line with the ALARA principle. Using O-arm registered (Medtronic, Inc.), three paediatric phantoms were employed to measure CTDI w doses with default and lowered exposure settings. Images from 126 scans were evaluated by two spinal surgeons and scores were compared (Kappa statistics). Effective doses were calculated. The recommended new low-dose 3-D spine protocols were then used in 15 children. The lowest acceptable exposure as judged by image quality for intraoperative use was 70 kVp/40 mAs, 70 kVp/80 mAs and 80 kVp/40 mAs for the 1-, 5- and 12-year-old-equivalent phantoms respectively (kappa = 0,70). Optimised dose settings reduced CTDI w doses 89-93%. The effective dose was 0.5 mSv (91-94,5% reduction). The optimised protocols were used clinically without problems. Radiation doses for intraoperative 3-D CT using a cone-beam flat-detector scanner could be reduced at least 89% compared to manufacturer settings and still be used to safely navigate pedicle screws. (orig.)

  13. Further development of LLNA:DAE method as stand-alone skin-sensitization testing method and applied for evaluation of relative skin-sensitizing potency between chemicals.

    Science.gov (United States)

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Itagaki, Hiroshi

    2015-04-01

    To date, there has been no well-established local lymph node assay (LLNA) that includes an elicitation phase. Therefore, we developed a modified local lymph node assay with an elicitation phase (LLNA:DAE) to discriminate true skin sensitizers from chemicals that gave borderline positive results and previously reported this assay. To develop the LLNA:DAE method as a useful stand-alone testing method, we investigated the complete procedure for the LLNA:DAE method using hexyl cinnamic aldehyde (HCA), isoeugenol, and 2,4-dinitrochlorobenzene (DNCB) as test compounds. We defined the LLNA:DAE procedure as follows: in the dose-finding test, four concentrations of chemical applied to dorsum of the right ear on days 1, 2, and 3 and dorsum of both ears on day 10. Ear thickness and skin irritation score were measured on days 1, 3, 5, 10, and 12. Local lymph nodes were excised and weighed on day 12. The test dose for the primary LLNA:DAE study was selected as the dose that gave the highest left ear lymph node weight in the dose-finding study, or the lowest dose that produced a left ear lymph node of over 4 mg. This procedure was validated using nine different chemicals. Furthermore, qualitative relationship was observed between the degree of elicitation response in the left ear lymph node and the skin sensitizing potency of 32 chemicals tested in this study and the previous study. These results indicated that LLNA:DAE method was as first LLNA method that was able to evaluate the skin sensitizing potential and potency in elicitation response.

  14. Passive dosing of triclosan in multi-generation tests with copepods - Stable exposure concentrations and effects at the low µg l-1 range

    DEFF Research Database (Denmark)

    Ribbenstedt, Anton; Mustajärvi, Lukas; Breitholtz, Magnus

    2017-01-01

    to test the applicability of passive dosing to maintain stable concentrations of the organochlorine bacteriocide triclosan in the water phase during a 6-week multi-generation population development test with the harpacticoid copepod Nitocra spinipes. Triclosan was loaded into silicone (1000 mg), which...... was used as passive dosing phase in the exposure vials. The distribution ratio for triclosan between silicone and water (Dsilicone-water ) was 10466 ± 1927. A population development test was conducted at three concentration levels of triclosan that were measured to be 3-5 µg L(-1) , 7-11 µg L(-1) and 16...... exerted on juvenile development. Progressively lower development index values in the populations exposed to increasing triclosan concentrations suggest developmental retardation. Our results further stress the need for chronic exposure during ecotoxicity testing in chemical risk assessment as even...

  15. A survey in Portuguese X-ray fluoroscopy equipment: dose rates and image quality

    International Nuclear Information System (INIS)

    Teixeira, Nuno G.; Cunha, Gilda R.; Coutinho, Guilherme M.; Trindade, Hugo R.; Carvoeiras, Pedro P.

    2015-01-01

    X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level. (authors)

  16. Lowest-energy cage structures of medium-sized (ZnO){sub n} clusters with n = 15 − 24

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Lingli; Sai, Linwei [School of Mathematical Sciences, Dalian University of Technology, Dalian 116024, China and College of Advanced Science and Technology, Dalian University of Technology, Dalian 116024 (China); Zhao, Jijun, E-mail: zhaojj@dlut.edu.cn [College of Advanced Science and Technology, Dalian University of Technology, Dalian 116024, China and Key Laboratory of Materials Modification by Laser, Ion and Electron Beams (Dalian University of Technology), Ministry of Education, Dalian 116024 (China); Qiu, Ruifeng [School of Mathematical Sciences, Dalian University of Technology, Dalian 116024 (China)

    2015-01-22

    Fullerene-like cage structures of medium-sized (ZnO){sub n} clusters with n = 15 − 24 were generated by spiral algorithm and optimized using density functional theory calculations. Most of these lowest-energy cage structures contain only four-membered and six-membered rings, whereas eight-membered rings were found in the lowest-energy cages of (ZnO){sub n} (n = 19, 20, 23, 24). Our best cage configurations either reproduce or prevail the previously reported ones. The size-dependent electronic properties were also discussed.

  17. The influence of geology on terrestrial gamma radiation dose rate in Pahang state, Malaysia

    International Nuclear Information System (INIS)

    Gabdo, H.T.; Ramli, A.T.; Sanusi, M.S.; Garba, N.N.; Saleh, M.A.

    2015-01-01

    Terrestrial gamma radiation dose (TGRD) rate measurements have been made in Pahang state, Malaysia. Significant variations were found between TGRD measurements and the underlying geological formations. In some cases revealing significant elevations of TGRD. The acid-intrusive geological formation has the highest mean TGRD measurement of 367 nGy/h -1 . This is more than six times the world average value of 59 nGy/h -1 , while the quaternary geological formation has the lowest mean gamma radiation dose rate of 99 nGy h -1 . The annual effective dose equivalent outdoor to the population was 0.216 mSv. The lifetime equivalent dose and relative lifetime cancer risks for an individual living in Pahang state were 81 mSv and 4.7 x 10 -3 respectively. These values are more than two times the world average of 34 mSv and 1.95 x 10 -3 respectively. (author)

  18. Comparison of dose length, area, and volume histograms as quantifiers of urethral dose in prostate brachytherapy

    International Nuclear Information System (INIS)

    Butler, Wayne M.; Merrick, Gregory S.; Dorsey, Anthony T.; Hagedorn, Brenda M.

    2000-01-01

    Purpose: To determine the magnitude of the differences between urethral dose-volume, dose-area, and dose-length histograms (DVH, DAH, and DLH, respectively, or DgH generically). Methods and Materials: Six consecutive iodine-125 ( 125 I) patients and 6 consecutive palladium-103 ( 103 Pd) patients implanted via a modified uniform planning approach were evaluated with day 0 computed tomography (CT)-based dosimetry. The urethra was identified by the presence of a urinary catheter and was hand drawn on the CT images with a mean radius of 3.3 ± 0.7 mm. A 0.1-mm calculation matrix was employed for the urethral volume and surface analysis, and urethral dose points were placed at the centroid of the urethra on each 5-mm CT slice. Results: Although individual patient DLHs were step-like, due to the sparseness of the data points, the composite urethral DLH, DAH, and DVHs were qualitatively similar. The DAH curve delivered more radiation than the other two curves at all doses greater than 90% of the prescribed minimum peripheral dose (mPD) to the prostate. In addition, the DVH curve was consistently higher than the DLH curve at most points throughout that range. Differences between the DgH curves were analyzed by integrating the difference curves between 0 and 200% of the mPD. The area-length, area-volume, and volume-length difference curves integrated in the ratio of 3:2:1. The differences were most pronounced near the inflection point of the DgH curves with mean A 125 , V 125 , and L 125 values of 36.6%, 31.4%, and 23.0%, respectively, of the urethra. Quantifiers of urethral hot spots such as D 10 , defined as the minimal dose delivered to the hottest 10% of the urethra, followed the same ranking: area analysis indicated the highest dose and length analysis, the lowest dose. D 10 was 148% and 136% of mPD for area and length evaluations, respectively. Comparing the two isotopes in terms of the amount of urethra receiving a given dose, 103 Pd implants were significantly

  19. Specific-locus mutation frequencies in mouse stem-cell spermatogonia at very low radiation dose rates, and their use in the estimation of genetic hazards of radiation in man

    International Nuclear Information System (INIS)

    Russell, W.L.; Kelly, E.M.

    1982-01-01

    Experiments were undertaken to augment the information on the lowest radiation dose rates feasible for scoring transmitted induced mutations detected by the specific-locus method in the mouse. This is the type of information most suitable for estimating genetic hazards of radiation in man. The results also aid in resolving conflicting possibilities about the relationship between mutation frequency and radiation dose at low dose rates

  20. Ultra-low dose dual-source high-pitch computed tomography of the paranasal sinus: diagnostic sensitivity and radiation dose

    International Nuclear Information System (INIS)

    Schulz, Boris; Zangos, Stefan; Friedrichs, Ingke; Bauer, Ralf W.; Kerl, Matthias; Vogl, Thomas J.; Martin M Mack, Martin M.; Potente, Stefan

    2012-01-01

    Background: Today's gold standard for diagnostic imaging of inflammatory diseases of the paranasal sinus is computed tomography (CT). Purpose: To evaluate diagnostic sensitivity and radiation dose of an ultra-low dose dual-source CT technique. Material and Methods: Paranasal sinuses of 14 cadaveric heads were independently evaluated by two readers using a modern dual-source CT with lowest reasonable dosage in high-pitch mode (100 kV, 10 mAs, collimation 0.6 mm, pitch value 3.0). Additionally the head part of an anthropomorphic Alderson-Rando phantom was equipped with thermoluminescent detectors to measure radiation exposure to the eye lenses and thyroid gland. Results: Diagnostic accuracy regarding sinusoidal fluid, nasal septum deviation, and mucosal swelling was 100%. Mastoid fluid was detected in 76% and 92%, respectively. In the phantom study, average measured eye lens dosage was 0.64 mGy; radiation exposure of the thyroid gland was 0.085 mGy. Conclusion: Regarding evaluation of inflammatory diseases of the paranasal sinus this study indicates sufficient accuracy of the proposed CT protocol at a very low dosage level

  1. Switching From Age-Based Stimulus Dosing to Dose Titration Protocols in Electroconvulsive Therapy: Empirical Evidence for Better Patient Outcomes With Lower Peak and Cumulative Energy Doses.

    Science.gov (United States)

    O'Neill-Kerr, Alex; Yassin, Anhar; Rogers, Stephen; Cornish, Janie

    2017-09-01

    The aim of this study was to test the proposition that adoption of a dose titration protocol may be associated with better patient outcomes, at lower treatment dose, and with comparable cumulative dose to that in patients treated using an age-based stimulus dosing protocol. This was an analysis of data assembled from archived records and based on cohorts of patients treated respectively on an age-based stimulus dosing protocol and on a dose titration protocol in the National Health Service in England. We demonstrated a significantly better response in the patient cohort treated with dose titration than with age-based stimulus dosing. Peak doses were less and the total cumulative dose was less in the dose titration group than in the age-based stimulus dosing group. Our findings are consistent with superior outcomes in patients treated using a dose titration protocol when compared with age-based stimulus dosing in a similar cohort of patients.

  2. Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch

    International Nuclear Information System (INIS)

    May, Matthias S.; Kuettner, Axel; Lell, Michael M.; Wuest, Wolfgang; Scharf, Michael; Uder, Michael; Deak, Paul; Kalender, Willi A.; Keller, Andrea K.; Haeberle, Lothar; Achenbach, Stephan; Seltmann, Martin

    2012-01-01

    To evaluate radiation dose levels in patients undergoing spiral coronary computed tomography angiography (CTA) on a dual-source system in clinical routine. Coronary CTA was performed for 56 patients with electrocardiogram-triggered tube current modulation (TCM) and heart-rate (HR) dependent pitch adaptation. Individual Monte Carlo (MC) simulations were performed for dose assessment. Retrospective simulations with constant tube current (CTC) served as reference. Lung tissue was segmented and used for organ and effective dose (ED) calculation. Estimates for mean relative ED was 7.1 ± 2.1 mSv/100 mAs for TCM and 12.5 ± 5.3 mSv/100 mAs for CTC (P 70 bpm, 29 ± 12%). However lowest ED is achieved at high HR (5.2 ± 1.5 mSv/100 mAs), compared with intermediate (6.7 ± 1.6 mSv/100 mAs) and low (8.3 ± 2.1 mSv/100 mAs) HR when automated pitch adaptation is applied. Radiation dose savings up to 52% are achievable by TCM at low and regular HR. However lowest ED is attained at high HR by pitch adaptation despite inferior radiation dose reduction by TCM. circle Monte Carlo simulations allow for individual radiation dose calculations. (orig.)

  3. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom.

    Science.gov (United States)

    Lesperance, Marielle; Inglis-Whalen, M; Thomson, R M

    2014-02-01

    simulations, the average dose to the lens is larger by 7%-9% than the dose to the center of the lens, and the maximum dose to the optic nerve is 17%-22% higher than the dose to the optic disk for all radionuclides. In general, when normalized to the same prescription dose at the tumor apex, doses delivered to all structures of interest in the full eye model are lowest for(103)Pd and highest for (131)Cs, except for the tumor where the average dose is highest for (103)Pd and lowest for (131)Cs. The eye is not radiologically water-equivalent, as doses from simulations of the plaque in the full eye model differ considerably from doses for the plaque in a water phantom and from simulated TG-43 calculated doses. This demonstrates the importance of model-based dose calculations for eye plaque brachytherapy, for which accurate elemental compositions of ocular media are necessary.

  4. Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom

    International Nuclear Information System (INIS)

    Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M.

    2014-01-01

    to 16%. In the full eye model simulations, the average dose to the lens is larger by 7%–9% than the dose to the center of the lens, and the maximum dose to the optic nerve is 17%–22% higher than the dose to the optic disk for all radionuclides. In general, when normalized to the same prescription dose at the tumor apex, doses delivered to all structures of interest in the full eye model are lowest for 103 Pd and highest for 131 Cs, except for the tumor where the average dose is highest for 103 Pd and lowest for 131 Cs. Conclusions : The eye is not radiologically water-equivalent, as doses from simulations of the plaque in the full eye model differ considerably from doses for the plaque in a water phantom and from simulated TG-43 calculated doses. This demonstrates the importance of model-based dose calculations for eye plaque brachytherapy, for which accurate elemental compositions of ocular media are necessary

  5. Plain radiography procedures in Sudan: examination frequency and collective dose

    International Nuclear Information System (INIS)

    Musa, B. E. Y.

    2010-12-01

    According to the previous studies diagnostic examinations are the largest man-made source to collective dose (CED) in world. It was observed that, despite of the large number of medical x-ray installations in Sudan and in particular conventional x-ray procedures, studies aimed at estimating collective effective dose in diagnostic radiology were lacking. The purpose of this study was to estimate the annual frequency of plain radiography examinations and to estimate the annual collective effective dose to Sudanese population due to plain radiography examinations, selected by their high frequencies or their relatively high doses delivered to patient. To have an idea about the typical examinations frequencies, data were collected from a sample of ten hospitals in Khartoum. The collected data provided information about the x-ray machine manufacture, year of installation and frequency of some examinations per day. The annual collective doses from all medical examinations to the population are: 441, 166, 630, 544, 276, 525, 30, 9, 12 and 161 man Sv from abdomen AP, chest AP, pelvis, lumbar spine PA, lumbar spain PA, lumbar- sacral joints, Skull AP, Skull LAT, Skull PA and from others examination, respectively. The resulting annual collective effective dose was evaluated 2793 man Sv, with the largest contribution of pelvis and LS examinations and lowest contribution of skull examinations. Collective effective dose resulting from the use of plain radiography examinations in the Sudan is small compared with global results. But that dose not negate the need to conduct radiological surveys in frequent intervals to meet the increase of successive x-ray equipment to try to estimate and reduce the doses of patients and the public. (Author)

  6. Investigation of the dose rate dependency of the PAGAT gel dosimeter at low dose rates

    International Nuclear Information System (INIS)

    Zehtabian, M.; Faghihi, R.; Zahmatkesh, M.H.; Meigooni, A.S.; Mosleh-Shirazi, M.A.; Mehdizadeh, S.; Sina, S.; Bagheri, S.

    2012-01-01

    Medical physicists need dosimeters such as gel dosimeters capable of determining three-dimensional dose distributions with high spatial resolution. To date, in combination with magnetic resonance imaging (MRI), polyacrylamide gel (PAG) polymers are the most promising gel dosimetry systems. The purpose of this work was to investigate the dose rate dependency of the PAGAT gel dosimeter at low dose rates. The gel dosimeter was used for measurement of the dose distribution around a Cs-137 source from a brachytherapy LDR source to have a range of dose rates from 0.97 Gy h −1 to 0.06 Gy h −1 . After irradiation of the PAGAT gel, it was observed that the dose measured by gel dosimetry was almost the same at different distances (different dose rates) from the source, although the points nearer the source had been expected to receive greater doses. Therefore, it was suspected that the PAGAT gel is dose rate dependent at low dose rates. To test this further, three other sets of measurements were performed by placing vials containing gel at different distances from a Cs-137 source. In the first two measurements, several plastic vials were exposed to equal doses at different dose rates. An ionization chamber was used to measure the dose rate at each distance. In addition, three TLD chips were simultaneously irradiated in order to verify the dose to each vial. In the third measurement, to test the oxygen diffusion through plastic vials, the experiment was repeated again using plastic vials in a nitrogen box and glass vials. The study indicates that oxygen diffusion through plastic vials for dose rates lower than 2 Gy h −1 would affect the gel dosimeter response and it is suggested that the plastic vials or (phantoms) in an oxygen free environment or glass vials should be used for the dosimetry of low dose rate sources using PAGAT gel to avoid oxygen diffusion through the vials.

  7. Using equilibrium passive dosing to maintain stable exposure concentrations of triclosan in a 6-week toxicity test

    DEFF Research Database (Denmark)

    Sobek, A.; Ribbenstedt, A.; Mustajärvi, L.

    2015-01-01

    toxicity tests. Yet, the European Commission’s criteria for chemicals’ risk assessments aim at protecting higher levels in the environment. To achieve protection of populations and ecosystems, reliable long-term ecotoxicologial tests are needed. In this study, we used equilibrium passive dosing to maintain...... stable exposure concentrations of triclosan (log Kow 4.8) in a 6-week multigeneration test with the benthic copepod Nitocra spinipes. The tests were performed in 10 mL vials casted with 1000 mg of silicone (DC 1-2577). Based on a previous pilot study, three triclosan concentrations were selected...... and tested (15 μg L-1; 30 μg L-1; 60 μg L-1) as well as a control (no triclosan). At test beginning, each vial contained 12 individuals consisting of 3 individuals from four different life stages. The test includes feeding with phytoplankton three times a week, which can lead to declining freely dissolved...

  8. Genetic efficiency of low-dose chronic irradiation in mammals and fish

    International Nuclear Information System (INIS)

    Goncharova, R.; Ryabokon, N.; Smolich, I.; Slukvin, A.

    2001-01-01

    The problem of biological effects of low-dose chronic irradiation is central radiobiological problem and seems to be very important for human monitoring and risk assessment Since 1986 we are engaged in studying genetic effects of low-dose chronic irradiation in natural populations of small mammals (bank vole - Clethrioiiomys glareolus) inhabiting radiocontaminated monitoring sites, in laboratory hybrid mice CBA*C57BI/6 j exposed to chronic irradiation at radiocontaminated sites, as well as in pond carp (Cyprinus carpio) reared in fish farms in areas contaminated due to the Chernobyl accident. The mean ground depositions in monitoring sites were 8-2330 kBq/m 2 and the mean bottom depositions in ponds were 52-3235 Bq/kg for Cs 137. We used conventional cytogenetics and genetics tests [1-3] and the following approaches in studying on genetic effects of low-dose chronic irradiation: Radiation exposures from external γ- and internal α, β, γ-irradiation from incorporated radionuclides were estimated for each specimen tested. Regression analysis of dose-effect relationships based on comparison of individual genetic end-points with individual absorbed doses was carried out We observed statistically significant changes in the frequencies of genetic end-points, which have been studied in somatic and germ cells, as well as in embryos of irradiated mammals and fish. So, the frequencies of chromosome aberrations in bank vole populations had up to 7-fold increase in comparison with background and pre-accident levels. It is of great importance to emphasize high radio-sensitivity of fertilized eggs (zygotes) and pond carp, embryos produced by chronically irradiated parents. Regression analysis allowed to reveal dependence of the studied parameters' frequencies on radiation exposure namely on the concentrations of basic dose forming radionuclides, absorbed dose rate and whole body absorbed dose. In most cases, dose-effect relationships were better approximated by non

  9. A Monte-Carlo simulation framework for joint optimisation of image quality and patient dose in digital paediatric radiography

    International Nuclear Information System (INIS)

    Menser, Bernd; Manke, Dirk; Mentrup, Detlef; Neitzel, Ulrich

    2016-01-01

    In paediatric radiography, according to the as low as reasonably achievable (ALARA) principle, the imaging task should be performed with the lowest possible radiation dose. This paper describes a Monte-Carlo simulation framework for dose optimisation of imaging parameters in digital paediatric radiography. Patient models with high spatial resolution and organ segmentation enable the simultaneous evaluation of image quality and patient dose on the same simulated radiographic examination. The accuracy of the image simulation is analysed by comparing simulated and acquired images of technical phantoms. As a first application example, the framework is applied to optimise tube voltage and pre-filtration in newborn chest radiography. At equal patient dose, the highest CNR is obtained with low-kV settings in combination with copper filtration. (authors)

  10. Technology development on production of test specimens from irradiated capsule outer-tube and mechanical evaluation test of stainless steel with high dose carried out by the technology

    International Nuclear Information System (INIS)

    Hayashi, Koji; Shibata, Akira; Iwamatsu, Shigemi; Sozawa, Shizuo; Takada, Fumiki; Ohmi, Masao; Nakagawa, Tetsuya

    2008-03-01

    The irradiation capsule 74M-52J was irradiated during total 136 cycles at reactor core of JMTR and the maximum neutron dose reached on 3.9x10 26 n/m 2 at the capsule outer-tube made of a type 304 stainless steel. In order to produce mechanical test specimens from the outer-tube, a punching technique was developed as a simple remote-handling method in a hot-cell. From comparison between the punching and the mechanical cutting methods, it was clarified that the punching technique was applicable to practical use. Moreover, an evaluation test of mechanical properties using specimens sampled from the 74M-52 was performed with in-water high temperature condition, less than 288degC. The result shows that the residual elongation is 18% at 150degC and 13% at 288degC. It was confirmed that the type 304 stainless steel irradiated up to such high dose shows enough ductility. (author)

  11. SU-D-BRB-01: A Comparison of Learning Methods for Knowledge Based Dose Prediction for Coplanar and Non-Coplanar Liver Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Tran, A; Ruan, D; Woods, K; Yu, V; Nguyen, D; Sheng, K [UCLA School of Medicine, Los Angeles, CA (United States)

    2016-06-15

    Purpose: The predictive power of knowledge based planning (KBP) has considerable potential in the development of automated treatment planning. Here, we examine the predictive capabilities and accuracy of previously reported KBP methods, as well as an artificial neural networks (ANN) method. Furthermore, we compare the predictive accuracy of these methods on coplanar volumetric-modulated arc therapy (VMAT) and non-coplanar 4π radiotherapy. Methods: 30 liver SBRT patients previously treated using coplanar VMAT were selected for this study. The patients were re-planned using 4π radiotherapy, which involves 20 optimally selected non-coplanar IMRT fields. ANNs were used to incorporate enhanced geometric information including liver and PTV size, prescription dose, patient girth, and proximity to beams. The performance of ANN was compared to three methods from statistical voxel dose learning (SVDL), wherein the doses of voxels sharing the same distance to the PTV are approximated by either taking the median of the distribution, non-parametric fitting, or skew-normal fitting. These three methods were shown to be capable of predicting DVH, but only median approximation can predict 3D dose. Prediction methods were tested using leave-one-out cross-validation tests and evaluated using residual sum of squares (RSS) for DVH and 3D dose predictions. Results: DVH prediction using non-parametric fitting had the lowest average RSS with 0.1176(4π) and 0.1633(VMAT), compared to 0.4879(4π) and 1.8744(VMAT) RSS for ANN. 3D dose prediction with median approximation had lower RSS with 12.02(4π) and 29.22(VMAT), compared to 27.95(4π) and 130.9(VMAT) for ANN. Conclusion: Paradoxically, although the ANNs included geometric features in addition to the distances to the PTV, it did not perform better in predicting DVH or 3D dose compared to simpler, faster methods based on the distances alone. The study further confirms that the prediction of 4π non-coplanar plans were more accurate than

  12. Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch

    Energy Technology Data Exchange (ETDEWEB)

    May, Matthias S.; Kuettner, Axel; Lell, Michael M.; Wuest, Wolfgang; Scharf, Michael; Uder, Michael [University of Erlangen, Department of Radiology, Erlangen (Germany); Deak, Paul; Kalender, Willi A. [University of Erlangen, Department of Medical Physics, Erlangen (Germany); Keller, Andrea K.; Haeberle, Lothar [University of Erlangen, Department of Medical Informatics, Biometry and Epidemiology, Erlangen (Germany); Achenbach, Stephan; Seltmann, Martin [University of Erlangen, Department of Cardiology, Erlangen (Germany)

    2012-03-15

    To evaluate radiation dose levels in patients undergoing spiral coronary computed tomography angiography (CTA) on a dual-source system in clinical routine. Coronary CTA was performed for 56 patients with electrocardiogram-triggered tube current modulation (TCM) and heart-rate (HR) dependent pitch adaptation. Individual Monte Carlo (MC) simulations were performed for dose assessment. Retrospective simulations with constant tube current (CTC) served as reference. Lung tissue was segmented and used for organ and effective dose (ED) calculation. Estimates for mean relative ED was 7.1 {+-} 2.1 mSv/100 mAs for TCM and 12.5 {+-} 5.3 mSv/100 mAs for CTC (P < 0.001). Relative dose reduction at low HR ({<=}60 bpm) was highest (49 {+-} 5%) compared to intermediate (60-70 bpm, 33 {+-} 12%) and high HR (>70 bpm, 29 {+-} 12%). However lowest ED is achieved at high HR (5.2 {+-} 1.5 mSv/100 mAs), compared with intermediate (6.7 {+-} 1.6 mSv/100 mAs) and low (8.3 {+-} 2.1 mSv/100 mAs) HR when automated pitch adaptation is applied. Radiation dose savings up to 52% are achievable by TCM at low and regular HR. However lowest ED is attained at high HR by pitch adaptation despite inferior radiation dose reduction by TCM. circle Monte Carlo simulations allow for individual radiation dose calculations. (orig.)

  13. Aging irradiation of polymers. Dose-rate and test sequence influence

    International Nuclear Information System (INIS)

    Alba, C.; Carlin, F.; Chenion, J.; Lemaire, F.; Le Meur, M.; Petitjean, M.

    1984-05-01

    This work brings up results of the irradiation dose-rate influence on mechanical and electrical properties of technical polymer materials evolution. Polymer samples were subjected to 3.3.10 -2 Gy.s -1 and 2.8.10 -1 Gy.s -1 dose-rate. Heat and radiation simultaneous action is usualy simulated sequentialy. The hardest simulation on the polymer is the sequence of irradiation followed by thermal aging not the reverse. This study was carried out on eight polymer materials among those used in the electrical appliances for P.W.R. nuclear power plants [fr

  14. A real-time regional adaptive exposure method for saving dose-area product in x-ray fluoroscopy

    International Nuclear Information System (INIS)

    Burion, Steve; Funk, Tobias; Speidel, Michael A.

    2013-01-01

    Purpose: Reduction of radiation dose in x-ray imaging has been recognized as a high priority in the medical community. Here the authors show that a regional adaptive exposure method can reduce dose-area product (DAP) in x-ray fluoroscopy. The authors' method is particularly geared toward providing dose savings for the pediatric population. Methods: The scanning beam digital x-ray system uses a large-area x-ray source with 8000 focal spots in combination with a small photon-counting detector. An imaging frame is obtained by acquiring and reconstructing up to 8000 detector images, each viewing only a small portion of the patient. Regional adaptive exposure was implemented by varying the exposure of the detector images depending on the local opacity of the object. A family of phantoms ranging in size from infant to obese adult was imaged in anteroposterior view with and without adaptive exposure. The DAP delivered to each phantom was measured in each case, and noise performance was compared by generating noise arrays to represent regional noise in the images. These noise arrays were generated by dividing the image into regions of about 6 mm 2 , calculating the relative noise in each region, and placing the relative noise value of each region in a one-dimensional array (noise array) sorted from highest to lowest. Dose-area product savings were calculated as the difference between the ratio of DAP with adaptive exposure to DAP without adaptive exposure. The authors modified this value by a correction factor that matches the noise arrays where relative noise is the highest to report a final dose-area product savings. Results: The average dose-area product saving across the phantom family was (42 ± 8)% with the highest dose-area product saving in the child-sized phantom (50%) and the lowest in the phantom mimicking an obese adult (23%). Conclusions: Phantom measurements indicate that a regional adaptive exposure method can produce large DAP savings without compromising

  15. Estimation of maximum credible atmospheric radioactivity concentrations and dose rates from nuclear tests

    International Nuclear Information System (INIS)

    Telegadas, K.

    1979-01-01

    A simple technique is presented for estimating maximum credible gross beta air concentrations from nuclear detonations in the atmosphere, based on aircraft sampling of radioactivity following each Chinese nuclear test from 1964 to 1976. The calculated concentration is a function of the total yield and fission yield, initial vertical radioactivity distribution, time after detonation, and rate of horizontal spread of the debris with time. calculated maximum credible concentrations are compared with the highest concentrations measured during aircraft sampling. The technique provides a reasonable estimate of maximum air concentrations from 1 to 10 days after a detonation. An estimate of the whole-body external gamma dose rate corresponding to the maximum credible gross beta concentration is also given. (author)

  16. Tests of the linearity assumption in the dose-effect relationship for radiation-induced cancer

    International Nuclear Information System (INIS)

    Cohen, A.F.; Cohen, B.L.

    1980-01-01

    The validity of the BEIR linear extrapolation to low doses of the dose-effect relationship for radiation induced cancer is tested by use of natural radiation making use of selectivity on type of cancer, smoking habits, sex, age group, geographic area and/or time period. For lung cancer, a linear interpolation between zero dose-zero effect and the data from radon-induced cancers in miners implies that the majority of all lung cancers among non-smokers are due to radon; since lung cancers in miners are mostly small-cell undifferentiated (SCU), a rather rare type in general, linearity over predicts the frequency of SCU lung cancers among non smokers by a factor of 10, and among non-smoking females age 25-44 by a factor of 24. Similarly, linearity predicts that the majority of all lung cancers early in this century were due to radon even after due consideration is given to cases missed by poor diagnostic efficiency (this matter is considered in some detail). For the 30-40 age range, linearity over predicts the total lung cancer rate at that time by a factor of 3-6; for SCU lung cancer, the over-prediction is by at least a factor of 10. Other causes of lung cancer are considered which further enhance the degree to which the linearity assumption over-estimates the effects of low level radiation. A similar analysis is applied to leukemia induced by natural radiation. It is concluded that the upper limit for this is not higher than estimates from the linearity hypothesis. (author)

  17. Life-span studies in 226Ra-injected animals: Effect of low doses, effect of a decorporative treatment

    International Nuclear Information System (INIS)

    Schoeters, G.E.R.; Vanderborght, O.L.J.

    1986-01-01

    A life-span radiation effects study was performed in mice injected with several doses of 226 Ra. The study included 788 male C57Bl mice. For the removal of the 226 Ra, half the mice were treated daily with a diet 5% of which was sodium-alginate. The experiment revealed that mice that received the lowest dose of 226 Ra lived significantly longer than controls, and, despite appreciable skeletal removal of 226 Ra as a result of decorporative treatment, no biological benefit was observed in treated animals. 19 refs., 4 figs., 3 tabs

  18. Performance standard for dose Calibrator

    CERN Document Server

    Darmawati, S

    2002-01-01

    Dose calibrator is an instrument used in hospitals to determine the activity of radionuclide for nuclear medicine purposes. International Electrotechnical Commission (IEC) has published IEC 1303:1994 standard that can be used as guidance to test the performance of the instrument. This paper briefly describes content of the document,as well as explains the assessment that had been carried out to test the instrument accuracy in Indonesia through intercomparison measurement.Its is suggested that hospitals acquire a medical physicist to perform the test for its dose calibrator. The need for performance standard in the form of Indonesia Standard is also touched.

  19. Three-point Green's function of massless QED in position space to lowest order

    International Nuclear Information System (INIS)

    Mitra, Indrajit

    2009-01-01

    The transverse part of the three-point Green's function of massless QED is determined to the lowest order in position space. Taken together with the evaluation of the longitudinal part in Mitra (2008) (J. Phys. A: Math. Theor. 41 315401), this gives a relation for QED which is analogous to the star-triangle relation. We relate our result to conformal-invariant three-point functions

  20. Low-dose radiation as an environmental agent affecting intrauterine development

    International Nuclear Information System (INIS)

    Kameyama, Yoshiro

    1982-01-01

    The low-dose radiation effects which have been recognized in mammalian teratological studies are direct injuries to the particularly radiosensitive tissues of embryo and fetus, and increased incidences of spontaneous malformations and minor anomalies. The lowest radiation doses for manifestation of those effects in mice and rats are: 5 rad for resorption of preimplantation embryos; 5-10 rad for acute cytological changes such as pyknosis, cytoplasmic degeneration and mitotic delay; 5 rad for increasing frequency of spontaneous minor anomalies of the skeleton; 15-20 rad for malformations of the eye, brain and spinal cord; 20-25 rad for histogenetic and functional disorders of the central nervous system; and 20-25 rad for impaired fertility. Pregnant women who are subject to X-ray examination are much concerned about potential hazard of radiation to their offspring in utero. The above experimental findings suggest that the possibility of teratogenic effects of diagnostic radiation on human embryos and fetuses is extremely low, and probably negligible, given the proper dose control measures. (author)

  1. Microbeams, microdosimetry and specific dose

    International Nuclear Information System (INIS)

    Randers-Pehrson, H.

    2002-01-01

    Dose and its usefulness as a single parameter to describe the amount of radiation absorbed are well established for most situations. The conditions where the concept of dose starts to break down are well known, mostly from the study of microdosimetry. For low doses of high LET radiation it is noted that the process of taking the limiting value of the energy absorbed within a test volume divided by the mass within that volume yields either zero or a relatively large value. The problem is further exacerbated with microbeam irradiations where the uniformity of the energy deposition is experimentally manipulated on the spatial scale of cells being irradiated. Booz introduced a quantity to deal with these problems: the unfortunately named 'mean specific energy in affected volumes'. This quantity multiplied by the probability that a test volume has received an energy deposit is equal to dose (in situations where dose can be defined). I propose that Booz's quantity be renamed 'specific dose', that is the mean energy deposited divided by the mass within a specified volume. If we believe for instance that the nucleus of a cell is the critical volume for biological effects, we can refer to the nuclear specific dose. A microbeam experiment wherein 10 per cent of the cell nuclei were targeted with 10 alpha particles would be described as delivering a nuclear specific dose of 1.6 Gy to 10 per cent of the population. (author)

  2. A dose error evaluation study for 4D dose calculations

    Science.gov (United States)

    Milz, Stefan; Wilkens, Jan J.; Ullrich, Wolfgang

    2014-10-01

    Previous studies have shown that respiration induced motion is not negligible for Stereotactic Body Radiation Therapy. The intrafractional breathing induced motion influences the delivered dose distribution on the underlying patient geometry such as the lung or the abdomen. If a static geometry is used, a planning process for these indications does not represent the entire dynamic process. The quality of a full 4D dose calculation approach depends on the dose coordinate transformation process between deformable geometries. This article provides an evaluation study that introduces an advanced method to verify the quality of numerical dose transformation generated by four different algorithms. The used transformation metric value is based on the deviation of the dose mass histogram (DMH) and the mean dose throughout dose transformation. The study compares the results of four algorithms. In general, two elementary approaches are used: dose mapping and energy transformation. Dose interpolation (DIM) and an advanced concept, so called divergent dose mapping model (dDMM), are used for dose mapping. The algorithms are compared to the basic energy transformation model (bETM) and the energy mass congruent mapping (EMCM). For evaluation 900 small sample regions of interest (ROI) are generated inside an exemplary lung geometry (4DCT). A homogeneous fluence distribution is assumed for dose calculation inside the ROIs. The dose transformations are performed with the four different algorithms. The study investigates the DMH-metric and the mean dose metric for different scenarios (voxel sizes: 8 mm, 4 mm, 2 mm, 1 mm 9 different breathing phases). dDMM achieves the best transformation accuracy in all measured test cases with 3-5% lower errors than the other models. The results of dDMM are reasonable and most efficient in this study, although the model is simple and easy to implement. The EMCM model also achieved suitable results, but the approach requires a more complex

  3. Testicular Doses in Image-Guided Radiotherapy of Prostate Cancer

    International Nuclear Information System (INIS)

    Deng Jun; Chen Zhe; Yu, James B.; Roberts, Kenneth B.; Peschel, Richard E.; Nath, Ravinder

    2012-01-01

    Purpose: To investigate testicular doses contributed by kilovoltage cone-beam computed tomography (kVCBCT) during image-guided radiotherapy (IGRT) of prostate cancer. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions from kVCBCT on 3 prostate cancer patients. Absorbed doses to various organs were compared between intensity-modulated radiotherapy (IMRT) treatments and kVCBCT scans. The impact of CBCT scanning mode, kilovoltage peak energy (kVp), and CBCT field span on dose deposition to testes and other organs was investigated. Results: In comparison with one 10-MV IMRT treatment, a 125-kV half-fan CBCT scan delivered 3.4, 3.8, 4.1, and 5.7 cGy to the prostate, rectum, bladder, and femoral heads, respectively, accounting for 1.7%, 3.2%, 3.2%, and 8.4% of megavoltage photon dose contributions. However, the testes received 2.9 cGy from the same CBCT scan, a threefold increase as compared with 0.7 cGy received during IMRT. With the same kVp, full-fan mode deposited much less dose to organs than half-fan mode, ranging from 9% less for prostate to 69% less for testes, except for rectum, where full-fan mode delivered 34% more dose. As photon beam energy increased from 60 to 125 kV, kVCBCT-contributed doses increased exponentially for all organs, irrespective of scanning mode. Reducing CBCT field span from 30 to 10 cm in the superior–inferior direction cut testicular doses from 5.7 to 0.2 cGy in half-fan mode and from 1.5 to 0.1 cGy in full-fan mode. Conclusions: Compared with IMRT, kVCBCT-contributed doses to the prostate, rectum, bladder, and femoral heads are clinically insignificant, whereas dose to the testes is threefold more. Full-fan CBCT usually deposits much less dose to organs (except for rectum) than half-fan mode in prostate patients. Kilovoltage CBCT–contributed doses increase exponentially with photon beam energy. Reducing CBCT field significantly cuts doses to testes and other organs.

  4. Testicular Doses in Image-Guided Radiotherapy of Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Deng Jun, E-mail: jun.deng@yale.edu [Department of Therapeutic Radiology, Yale University, New Haven, CT (United States); Chen Zhe; Yu, James B.; Roberts, Kenneth B.; Peschel, Richard E.; Nath, Ravinder [Department of Therapeutic Radiology, Yale University, New Haven, CT (United States)

    2012-01-01

    Purpose: To investigate testicular doses contributed by kilovoltage cone-beam computed tomography (kVCBCT) during image-guided radiotherapy (IGRT) of prostate cancer. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions from kVCBCT on 3 prostate cancer patients. Absorbed doses to various organs were compared between intensity-modulated radiotherapy (IMRT) treatments and kVCBCT scans. The impact of CBCT scanning mode, kilovoltage peak energy (kVp), and CBCT field span on dose deposition to testes and other organs was investigated. Results: In comparison with one 10-MV IMRT treatment, a 125-kV half-fan CBCT scan delivered 3.4, 3.8, 4.1, and 5.7 cGy to the prostate, rectum, bladder, and femoral heads, respectively, accounting for 1.7%, 3.2%, 3.2%, and 8.4% of megavoltage photon dose contributions. However, the testes received 2.9 cGy from the same CBCT scan, a threefold increase as compared with 0.7 cGy received during IMRT. With the same kVp, full-fan mode deposited much less dose to organs than half-fan mode, ranging from 9% less for prostate to 69% less for testes, except for rectum, where full-fan mode delivered 34% more dose. As photon beam energy increased from 60 to 125 kV, kVCBCT-contributed doses increased exponentially for all organs, irrespective of scanning mode. Reducing CBCT field span from 30 to 10 cm in the superior-inferior direction cut testicular doses from 5.7 to 0.2 cGy in half-fan mode and from 1.5 to 0.1 cGy in full-fan mode. Conclusions: Compared with IMRT, kVCBCT-contributed doses to the prostate, rectum, bladder, and femoral heads are clinically insignificant, whereas dose to the testes is threefold more. Full-fan CBCT usually deposits much less dose to organs (except for rectum) than half-fan mode in prostate patients. Kilovoltage CBCT-contributed doses increase exponentially with photon beam energy. Reducing CBCT field significantly cuts doses to testes and other organs.

  5. Change in Body Mass Index Associated With Lowest Mortality in Denmark, 1976-2013.

    Science.gov (United States)

    Afzal, Shoaib; Tybjærg-Hansen, Anne; Jensen, Gorm B; Nordestgaard, Børge G

    2016-05-10

    Research has shown a U-shaped pattern in the association of body mass index (BMI) with mortality. Although average BMI has increased over time in most countries, the prevalence of cardiovascular risk factors may also be decreasing among obese individuals over time. Thus, the BMI associated with lowest all-cause mortality may have changed. To determine whether the BMI value that is associated with the lowest all-cause mortality has increased in the general population over a period of 3 decades. Three cohorts from the same general population enrolled at different times: the Copenhagen City Heart Study in 1976-1978 (n = 13,704) and 1991-1994 (n = 9482) and the Copenhagen General Population Study in 2003-2013 (n = 97,362). All participants were followed up from inclusion in the studies to November 2014, emigration, or death, whichever came first. For observational studies, BMI was modeled using splines and in categories defined by the World Health Organization. Body mass index was calculated as weight in kilograms divided by height in meters squared. Main outcome was all-cause mortality and secondary outcomes were cause-specific mortality. The number of deaths during follow-up was 10,624 in the 1976-1978 cohort (78% cumulative mortality; mortality rate [MR], 30/1000 person-years [95%CI, 20-46]), 5025 in the 1991-1994 cohort (53%; MR, 16/1000 person-years [95%CI, 9-30]), and 5580 in the 2003-2013 cohort (6%;MR, 4/1000 person-years [95%CI, 1-10]). Except for cancer mortality, the association of BMI with all-cause, cardiovascular, and other mortality was curvilinear (U-shaped). The BMI associated with the lowest all-cause mortality increased by 3.3 from the 1976-1978 cohort compared with the 2003-2013 cohort. [table: see text] The multivariable-adjusted hazard ratios for all-cause mortality for BMI of 30 or more vs BMI of 18.5 to 24.9 were 1.31 (95%CI, 1.23-1.39;MR, 46/1000 person-years [95%CI, 32-66] vs 28/1000 person-years [95%CI, 18-45]) in the 1976

  6. Does the Lowest Bid Price Evaluation Criterion Make for a More Efficient Public Procurement Selection Criterion? (Case of the Czech Republic

    Directory of Open Access Journals (Sweden)

    Ochrana František

    2015-06-01

    Full Text Available Through the institute of public procurement a considerable volume of financial resources is allocated. It is therefore in the interest of contracting entities to seek ways of how to achieve an efficient allocation of resources. Some public contract-awarding entities, along with some public-administration authorities in the Czech Republic, believe that the use of a single evaluation criterion (the lowest bid price results in a more efficient tender for a public contract. It was found that contracting entities in the Czech Republic strongly prefer to use the lowest bid price criterion. Within the examined sample, 86.5 % of public procurements were evaluated this way. The analysis of the examined sample of public contracts proved that the choice of an evaluation criterion, even the preference of the lowest bid price criterion, does not have any obvious impact on the final cost of a public contract. The study concludes that it is inappropriate to prefer the criterion of the lowest bid price within the evaluation of public contracts that are characterised by their complexity (including public contracts for construction works and public service contracts. The findings of the Supreme Audit Office related to the inspection of public contracts indicate that when using the lowest bid price as an evaluation criterion, a public contract may indeed be tendered with the lowest bid price, but not necessarily the best offer in terms of supplied quality. It is therefore not appropriate to use the lowest bid price evaluation criterion to such an extent for the purpose of evaluating work and services. Any improvement to this situation requires a corresponding amendment to the Law on Public Contracts and mainly a radical change in the attitude of the Office for the Protection of Competition towards proposed changes, as indicated within the conclusions and recommendations proposed by this study.

  7. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    International Nuclear Information System (INIS)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul

    2012-01-01

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 μSv), followed by AZ3000CT (332.4 μSv), Somatom Emotion 6 (199.38 μSv), and 3D eXaM (111.6 μSv); it was the lowest for Implagraphy (83.09 μSv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  8. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2012-06-15

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 {mu}Sv), followed by AZ3000CT (332.4 {mu}Sv), Somatom Emotion 6 (199.38 {mu}Sv), and 3D eXaM (111.6 {mu}Sv); it was the lowest for Implagraphy (83.09 {mu}Sv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  9. Peripheral doses from pediatric IMRT

    International Nuclear Information System (INIS)

    Klein, Eric E.; Maserang, Beth; Wood, Roy; Mansur, David

    2006-01-01

    Peripheral dose (PD) data exist for conventional fields (≥10 cm) and intensity-modulated radiotherapy (IMRT) delivery to standard adult-sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from 2 to 10 cm). Data were collected at distances ranging from 5 to 72 cm away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three-dimensional (3D) plans for the same patient/target/dose (180 cGy), were optimized without limitation to the number of fields or wedge use. Six MV, 120-leaf MLC Varian axial beams were used. A phantom mimicking a 3-year-old was configured per Center for Disease Control data. Micro (0.125 cc) and cylindrical (0.6 cc) ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the 10 -10 scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high-energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from

  10. The Lowest Spin and Parity Levels on Two Particle System for Odd-oddNuclei 60Co and 46K

    International Nuclear Information System (INIS)

    Wardhani, VIS; Siagian, Toga

    2000-01-01

    For obtaining the lowest spin and parity levels of odd-odd nuclei, theanalyzing of the nuclei 60 Co and 46 K has been done using delta forcemodel. The calculation is done by theoretically and compared with experiment.To get a result optimally, the data analyzed using least square method. It isshown that the lowest spin and parity level from calculation result and theexperiment result are similar. (author)

  11. Isobio software: biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model.

    Science.gov (United States)

    Jaikuna, Tanwiwat; Khadsiri, Phatchareewan; Chawapun, Nisa; Saekho, Suwit; Tharavichitkul, Ekkasit

    2017-02-01

    To develop an in-house software program that is able to calculate and generate the biological dose distribution and biological dose volume histogram by physical dose conversion using the linear-quadratic-linear (LQL) model. The Isobio software was developed using MATLAB version 2014b to calculate and generate the biological dose distribution and biological dose volume histograms. The physical dose from each voxel in treatment planning was extracted through Computational Environment for Radiotherapy Research (CERR), and the accuracy was verified by the differentiation between the dose volume histogram from CERR and the treatment planning system. An equivalent dose in 2 Gy fraction (EQD 2 ) was calculated using biological effective dose (BED) based on the LQL model. The software calculation and the manual calculation were compared for EQD 2 verification with pair t -test statistical analysis using IBM SPSS Statistics version 22 (64-bit). Two and three-dimensional biological dose distribution and biological dose volume histogram were displayed correctly by the Isobio software. Different physical doses were found between CERR and treatment planning system (TPS) in Oncentra, with 3.33% in high-risk clinical target volume (HR-CTV) determined by D 90% , 0.56% in the bladder, 1.74% in the rectum when determined by D 2cc , and less than 1% in Pinnacle. The difference in the EQD 2 between the software calculation and the manual calculation was not significantly different with 0.00% at p -values 0.820, 0.095, and 0.593 for external beam radiation therapy (EBRT) and 0.240, 0.320, and 0.849 for brachytherapy (BT) in HR-CTV, bladder, and rectum, respectively. The Isobio software is a feasible tool to generate the biological dose distribution and biological dose volume histogram for treatment plan evaluation in both EBRT and BT.

  12. Estimation of effective dose to public from external exposure to natural background radiation in saudi arabia

    International Nuclear Information System (INIS)

    Khalid, A. A.

    2003-01-01

    The effective dose values in sixteen cities in Saudi Arabia due to external exposure to natural radiation were evaluated. These doses are based on natural background components including external exposure to terrestrial radiation and cosmic rays. The importance of evaluating the effective dose to the public due to external exposure to natural background radiation lies in its epidemiological and dosimetric importance and in forming a basis for the assessment of the level of radioactive contamination or pollution in the environment in the future. The exposure to terrestrial radiation was measured using thermoluminescent dosimeters (TLD). The exposure from cosmic radiation was determined using empirical correlation. The values evaluated for the total annual effective dose in all cities were within the world average values. The highest total annual effective dose measured in Al-Khamis city was 802 μSv/y, as compared to 305 μSv/y in Dammam city, which was considered the lowest value

  13. Influence of low Gamma Irradiation Doses And Weed Control On Faba Bean (VICIA FABA L.) Yield Attributes

    International Nuclear Information System (INIS)

    Farag, I.A.A; Abd El Hameed, I.M

    2013-01-01

    Two field experiments were carried out in an administration field at Belbees district, Sharkia Governorate, Egypt, during two successive winter seasons (2007⁄08-2008⁄09). The study aimed to investigate the effect of four gamma irradiation doses (un irradiated seeds as a control, 10,20 and 30 Gy)and five treatments of weed management practices 1- Un weeded (control), 2- Two hand hoeings at 21 and 42 days after sowing, 3- prometryn, commercially known as Gizagared,, sprayed at pre-emergence with rate of 1 Kg⁄300 liters⁄fad. 4-Bentazon 48⁒, commercially known as Basagran 48⁒ ,sprayed at pre-emergence with the rate of 500 Cm 3 ⁄200 ;liters water⁄fad. Sprayed at pre-emergence. 5-48⁒ sprayed at pre-emergence with the rate of 500 cm 3 ⁄200 liters water⁄fad. On yield and yield attributes of faba bean. Results indicate that :1- Gamma irradiation with the lowest dose of 10 Gy, gave high values for plant height (112.54 cm) and number of pods⁄plant (12.22), while the highest gamma irradiation dose of 30 Gy, resulted in high values for number of seeds⁄pod (4.52), number of seeds⁄plant (52.3) , seed weight (g)⁄plant, 100- seeds weight (79.79 g), seed yield (11.39 ardab⁄fad) and straw yield (ton⁄fad). The lowest values for each of the aforementioned traits were obtained in non irradiated treatment in the combined analysis 2- Weed control by hand hoeing twice (after 21 and 24 DAS) gave the highest values for each of the aforementioned traits, followed by spraying both herbicides., prometryn + bentazon 48⁒ followed by sole herbicide Bentazon 48⁒ and sole prometryn, while unweeded treatment gave the lowest values for the respective order, in the combined analysis.

  14. Research on dose setting for radiation sterilization of medical device

    International Nuclear Information System (INIS)

    Zhang Tongcheng; Liu Qingfang; Zhong Hongliang; Mi Zhisu; Wang Chunlei; Jiang Jianping

    2002-01-01

    Objective: To establish the radiation sterilization dose for medical devices using data of bioburden on the medical device. Methods: Firstly determination of recovery ratio and correction coefficient of the microbiological test method was used according to ISO11737 standard, then determination of bioburden on the products, finally the dose setting was completed based on the Method 1 in ISO11137 standard. Results: Fifteen kinds of medical devices were tested. Bioburden range was from 8.6-97271.2 CFU/device, recovery ration range 54.6%-100%, correction co-efficiency range 1.00-1.83, D 10 distribution from 1.40 to 2.82 kGy, verification dose (dose at SAL = 10 -2 ) range 5.1-17.6 kGy and sterilization dose (dose at SAL 10 -6 ) range 17.5-32.5 kGy. Conclusion: One hundred samples of each kind of product were exposed to the pre-determined verification dose and then the sterility test was performed. Each sterility test showed positive number was not greater than two. This indicated that the sterilization dose established for each kind of product was statistically acceptable

  15. High dose brain CT with ioxaglate and diatrizoate adverse reactions and effects on urine protein tests

    International Nuclear Information System (INIS)

    Raininko, R.; Laivola, J.; Irjala, K.; Turku Univ. Central Hospital

    1988-01-01

    Sodium meglumine ioxaglate (320 or 306 mg I/ml) and meglumine diatrizoate (306 mg I/ml) in an intravenous dose of 2 ml/kg were compared in a randomized double-blind test on the brain CT of 209 patients. Side effects were noted in 56% of the ioxaglate group and 90% of the diatrizoate group. Diatrizoate caused a sensation of heat significantly more often and more intensely, but the frequencies of other side effects did not differ significantly. No severe reactions occurred. The quality of the CT scans was equal. Neither ioxaglate nor diatrizoate impaired renal function. False-positive strip tests and falsely elevated protein values measured by the biuretic method were found in particular in the ioxaglate group. The results of urine protein measurements and strip tests are misleading on the day of the examination with both ioxaglate and diatrizoate. (orig.)

  16. N-representability of the Jastrow wave function pair density of the lowest-order.

    Science.gov (United States)

    Higuchi, Katsuhiko; Higuchi, Masahiko

    2017-08-08

    Conditions for the N-representability of the pair density (PD) are needed for the development of the PD functional theory. We derive sufficient conditions for the N-representability of the PD that is calculated from the Jastrow wave function within the lowest order. These conditions are used as the constraints on the correlation function of the Jastrow wave function. A concrete procedure to search the suitable correlation function is also presented.

  17. On-Line High Dose-Rate Gamma Ray Irradiation Test of the CCD/CMOS Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Jeong, Kyung Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    In this paper, test results of gamma ray irradiation to CCD/CMOS cameras are described. From the CAMS (containment atmospheric monitoring system) data of Fukushima Dai-ichi nuclear power plant station, we found out that the gamma ray dose-rate when the hydrogen explosion occurred in nuclear reactors 1{approx}3 is about 160 Gy/h. If assumed that the emergency response robot for the management of severe accident of the nuclear power plant has been sent into the reactor area to grasp the inside situation of reactor building and to take precautionary measures against releasing radioactive materials, the CCD/CMOS cameras, which are loaded with the robot, serve as eye of the emergency response robot. In the case of the Japanese Quince robot system, which was sent to carry out investigating the unit 2 reactor building refueling floor situation, 7 CCD/CMOS cameras are used. 2 CCD cameras of Quince robot are used for the forward and backward monitoring of the surroundings during navigation. And 2 CCD (or CMOS) cameras are used for monitoring the status of front-end and back-end motion mechanics such as flippers and crawlers. A CCD camera with wide field of view optics is used for monitoring the status of the communication (VDSL) cable reel. And another 2 CCD cameras are assigned for reading the indication value of the radiation dosimeter and the instrument. In the preceding assumptions, a major problem which arises when dealing with CCD/CMOS cameras in the severe accident situations of the nuclear power plant is the presence of high dose-rate gamma irradiation fields. In the case of the DBA (design basis accident) situations of the nuclear power plant, in order to use a CCD/CMOS camera as an ad-hoc monitoring unit in the vicinity of high radioactivity structures and components of the nuclear reactor area, a robust survivability of this camera in such intense gamma-radiation fields therefore should be verified. The CCD/CMOS cameras of various types were gamma irradiated at a

  18. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    Energy Technology Data Exchange (ETDEWEB)

    Ehlerman, D A.E. [Institute of Process Engineering, Federal Research Centre for Nutrition, Karlsruhe (Germany)

    2001-03-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  19. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    International Nuclear Information System (INIS)

    Ehlerman, D.A.E.

    2001-01-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  20. Low-dose effect of developmental bisphenol A exposure on sperm count and behaviour in rats.

    Science.gov (United States)

    Hass, U; Christiansen, S; Boberg, J; Rasmussen, M G; Mandrup, K; Axelstad, M

    2016-07-01

    Bisphenol A is widely used in food contact materials and other products and is detected in human urine and blood. Bisphenol A may affect reproductive and neurological development; however, opinion of the European Food Safety Authority (EFSA) on bisphenol A (EFSA J, 13, 2015 and 3978) concluded that none of the available studies were robust enough to provide a point of departure for setting a tolerable daily intake for bisphenol A. In the present study, pregnant Wistar rats (n = 17-21) were gavaged from gestation day 7 to pup day 22 with bisphenol A doses of 0, 25 μg, 250 μg, 5 mg or 50 mg/kg bw/day. In the offspring, growth, sexual maturation, weights and histopathology of reproductive organs, oestrus cyclicity and sperm counts were assessed. Neurobehavioural development was investigated using a behavioural testing battery including tests for motor activity, sweet preference, anxiety and spatial learning. Decreased sperm count was found at the lowest bisphenol A dose, that is 25 μg/kg/day, but not at the higher doses. Reproductive organ weight and histology were not affected and no behavioural effects were seen in male offspring. In the female offspring, exposure to 25 μg/kg bw/day bisphenol A dose resulted in increased body weight late in life and altered spatial learning in a Morris water maze, indicating masculinization of the brain. Decreased intake of sweetened water was seen in females from the highest bisphenol A dose group, also a possible sign of masculinization. The other investigated endpoints were not significantly affected. In conclusion, the present study using a robust experimental study design, has shown that developmental exposure to 25 μg/kg bw/day bisphenol A can cause adverse effects on fertility (decreased sperm count), neurodevelopment (masculinization of spatial learning in females) and lead to increased female body weight late in life. These results suggest that the new EFSA temporary tolerable daily intake of 4 μg/kg bw

  1. Required accuracy and dose thresholds in individual monitoring

    DEFF Research Database (Denmark)

    Christensen, P.; Griffith, R.V.

    1994-01-01

    this uncertainty factor, a value of 21% can be evaluated for the allowable maximum overall standard deviation for dose measurements at dose levels near the annual dose limits increasing to 45% for dose levels at the lower end of the dose range required to be monitored. A method is described for evaluating...... the overall standard deviation of the dosimetry system by combining random and systematic uncertainties in quadrature, and procedures are also given for determining each individual uncertainty connected to the dose measurement. In particular, attention is paid to the evaluation of the combined uncertainty due...... to energy and angular dependencies of the dosemeter. In type testing of personal dosimetry systems, the estimated overall standard deviation of the dosimetry system is the main parameter to be tested. An important characteristic of a personal dosimetry system is its capability of measuring low doses...

  2. The effects of environmental factors and experimental method on the results of low dose rate microprocessor irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Laviron, A; Gerard, G [Commissariat a l' Energie Atomique, IPSN, Centre d' Etudes de Valduc, Is-sur-Tille (France); Gauthier, G; Henry, J Y; Le Meur, M [Commissariat a l' Energie Atomique, IPSN, Fontenay-aux-Roses (France)

    1992-02-01

    As part of the safety studies of nuclear facilities, a series of experiments have been in progress over a number of years to determine the principal parameters for which allowance needs to be made in the testing of microprocessors in low dose rate nuclear irradiation environments. This paper contains a brief description of the results already published, followed by a review of the latest results obtained, specifically as concerns the effects of temperature, the origin of the batch, the angle of incidence of the radiation and the test routine used. (author)

  3. People in sub-Saharan Africa rate their health and health care among the lowest in the world.

    Science.gov (United States)

    Deaton, Angus S; Tortora, Robert

    2015-03-01

    The health of people in sub-Saharan Africa is a major global concern. However, data are weak, and little is known about how people in the region perceive their health or their health care. We used data from the Gallup World Poll in 2012 to document sub-Saharan Africans' perceived health status, their satisfaction with health care, their contact with medical professionals, and the priority they attach to health care. In comparison to other regions of the world, sub-Saharan Africa has the lowest ratings for well-being and the lowest satisfaction with health care. It also has the second-lowest perception of personal health, after only the former Soviet Union and its Eastern European satellites. HIV prevalence is positively correlated with perceived improvements in health care in countries with high prevalence. This is consistent with an improvement in at least some health care services as a result of the largely aid-funded rollout of antiretroviral treatment. Even so, sub-Saharan Africans do not prioritize health care as a matter of policy, although donors are increasingly shifting their aid efforts in the region toward health. Project HOPE—The People-to-People Health Foundation, Inc.

  4. Lowest vibrational states of 4He3He+: Non-Born-Oppenheimer calculations

    International Nuclear Information System (INIS)

    Stanke, Monika; Bubin, Sergiy; Kedziera, Dariusz; Molski, Marcin; Adamowicz, Ludwik

    2007-01-01

    Very accurate quantum mechanical calculations of the first five vibrational states of the 4 He 3 He + molecular ion are reported. The calculations have been performed explicitly including the coupling of the electronic and nuclear motions [i.e., without assuming the Born-Oppenheimer (BO) approximation]. The nonrelativistic non-BO wave functions were used to calculate the α 2 relativistic mass velocity, Darwin, and spin-spin interaction corrections. For the lowest vibrational transition, whose experimental energy is established with high precision, the calculated and the experimental results differ by only 0.16 cm -1

  5. Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications

    International Nuclear Information System (INIS)

    Loubele, M.; Bogaerts, R.; Van Dijck, E.; Pauwels, R.; Vanheusden, S.; Suetens, P.; Marchal, G.

    2009-01-01

    Objectives: To compare the effective dose levels of cone beam computed tomography (CBCT) for maxillofacial applications with those of multi-slice computed tomography (MSCT). Study design: The effective doses of 3 CBCT scanners were estimated (Accuitomo 3D, i-CAT, and NewTom 3G) and compared to the dose levels for corresponding image acquisition protocols for 3 MSCT scanners (Somatom VolumeZoom 4, Somatom Sensation 16 and Mx8000 IDT). The effective dose was calculated using thermoluminescent dosimeters (TLDs), placed in a Rando Alderson phantom, and expressed according to the ICRP 103 (2007) guidelines (including a separate tissue weighting factor for the salivary glands, as opposed to former ICRP guidelines). Results: Effective dose values ranged from 13 to 82 μSv for CBCT and from 474 to 1160 μSv for MSCT. CBCT dose levels were the lowest for the Accuitomo 3D, and highest for the i-CAT. Conclusions: Dose levels for CBCT imaging remained far below those of clinical MSCT protocols, even when a mandibular protocol was applied for the latter, resulting in a smaller field of view compared to various CBCT protocols. Considering this wide dose span, it is of outmost importance to justify the selection of each of the aforementioned techniques, and to optimise the radiation dose while achieving a sufficient image quality. When comparing these results to previous dosimetric studies, a conversion needs to be made using the latest ICRP recommendations.

  6. Low-dose x-radiation and congenital anomalies

    International Nuclear Information System (INIS)

    Kameyama, Yoshiro

    1983-01-01

    Among radiation effects on developing embryos and fetuses, occurrence of germinal mutation due to exposure of the gonads and postnatal manifestation of neoplasms are considered to be stochastic effects from the aspect of radiation protection. On the other hand, somatic effects such as teratogenic and embryo-toxic effects can be regarded as nonstochastic ones with threshold doses. In experimental teratological studies with mice and rats, the lowest radiation doses for manifestation of the non-stochastic somatic effects which have been recognized so far are:5 rad for resorption of preimplantation embryos; 5-10 rad for acute cytological changes such as pyknosis, cytoplasmic degeneration and mitotic delay; 5 rad for increasing frequency of spontaneous minor anomalies of the skeleton; 15-20 rad for malformations of the eye, brain and spinal cord; 20-25 rad for histogenetic and functional disorders of the central nervous system; and 20-25 rad for impaired fertility. Pregnant women who are subject to X-ray examinations are much concerned about potential hazard of radiation to their offspring in utero. The above experimental findings suggest that the possibility of non-stochastic somatic effects of diagnostic radiation on human embryos and fetuses is extremely low, and probably negligible, given the proper dose control measures. Possible effects which should be considered for risk evaluation of diagnostic exposure are two stochastic effects, carcinogenic and mutagenic. (author)

  7. Optimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations

    Directory of Open Access Journals (Sweden)

    Soo-Foon Moey

    2018-01-01

    Full Text Available IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization involved ninety physically abled patients aged between 20 to 60 years and weighed between 60 and 80 kilograms for four common digital radiographic examinations. Kerma X_plus, DAP meter was utilized to measure the entrance surface dose (ESD while effective dose (ED was estimated using CALDose_X 5.0 Monte Carlo software. The second phase, an experimental study utilized an anthropomorphic phantom (PBU-50 and Leeds test object TOR CDR for relative comparison of image quality. For the optimization phase, the imaging parameters with acceptable image quality and lowest ESD from the experimental study was related to patient’s body thickness. Image quality were evaluated by two radiologists using the modified evaluation criteria score lists. ResultsSignificant differences were found for image quality for all examinations. However significant difference for ESD were found for PA chest and AP abdomen only. The ESD for three of the examinations were lower than all published data. Additionally, the ESD and ED obtained for all examinations were lower than that recommended by radiation regulatory bodies. ConclusionOptimization of image quality and dose was achieved by utilizing an appropriate tube potential, calibrated automatic exposure control and additional filtration of 0.2mm copper.

  8. External dose estimates for future Bikini Atoll inhabitants

    International Nuclear Information System (INIS)

    Gudiksen, P.H.; Crites, T.R.; Robison, W.L.

    1976-01-01

    To evaluate the potential radiation doses that may be received by the returning Bikinians, we surveyed the residual radioactivity on Bikini and Eneu Islands in June of 1975. An integral part of the survey included measurements of gamma-ray exposure rates which are used to estimate external gamma-ray doses. The survey showed that on Bikini Island the rates are highly variable: values near the shores are generally of the order of 10 to 20 μR/h, while those within the interior average about 40 μR/h with a range of roughly 30 to 100 μR/h. Eneu Island, however, is characterized by more or less uniformly distributed gamma radiation levels of less than 10 μR/h over the entire island. These data, in conjunction with population statistics and expected life styles, allowed us to estimate the potential external gamma-ray doses associated with proposed housing locations along the lagoon road and within the interior portions of Bikini Island as well as along the lagoon side of Eneu Island. As expected, living on Eneu Island results in the lowest doses: 0.12 rem during the first year and 2.9 rem during 30 years. The highest values, 0.28 rem during the first year and 5.9 rem over 30 years, may potentially be received by inhabitants living within the interior of Bikini Island. Other options under consideration produce intermediate values

  9. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients

    Science.gov (United States)

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F.; Long, Daniel J.; Bolch, Wesley E.; Liu, Bob; Xu, X. George

    2015-07-01

    This paper describes the development and testing of VirtualDose—a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the ‘software as a service (SaaS)’ delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose’s functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT—two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.

  10. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients

    International Nuclear Information System (INIS)

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F; Xu, X George; Long, Daniel J; Bolch, Wesley E; Liu, Bob

    2015-01-01

    This paper describes the development and testing of VirtualDose—a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the ‘software as a service (SaaS)’ delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose’s functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT—two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations. (paper)

  11. Dose optimization in computed tomography: ICRP 87

    International Nuclear Information System (INIS)

    2007-01-01

    The doses given in the use of computed tomography scans are studied, aiming to calibrate the limits of irradiation in patients who need these tests. Furthermore, a good value of computed tomography should be guaranteed by physicians and radiologists for people not being irradiated unfairly, reducing doses and unnecessary tests. A critical evaluation by an ethics committee is suggested for cases where the test is performed for medical research without a cause [es

  12. Performance test of a portable TLD system for accidental doses

    International Nuclear Information System (INIS)

    Mihelic, M.; Stuhec, M.; Mitic, D.; Vekic, B.; Miljanic, S.; Ban, R.

    2005-01-01

    Full text: A portable TLD measuring system was constructed at the J. Stefan Institute many years ago, motivated by the thread of a catastrophic nuclear event. It was designed for fast measurements in accidental dosimetry mainly for military and civil protection use. The system consists of a robust portable measuring unit built for measurements in field conditions, sized about 40 cm in diameter and weighting 5 kg. Dosimeters are based on CaF 2 :Mn ceramic tablets closed in water resistant plastic housings. In original design producer assured measuring range from cGy to kGy. Specially designed energy compensating filters are used to satisfy requirements for energy response from 0,1 to 3 MeV. Stability of readings is maintained with the temperature stabilized light source. Measuring time for manually driven heating-reading cycle of one dosimeter is about 30 sec. Many systems of the type with sets of dosimeters were stored unused for some years in depositories of different institutions. Modernization of equipment in last years raised questions of applicability of such measurement systems for contemporary needs. The system was thus tested in a secondary standards dosimetry laboratory for compliance with up to date requirements for accidental individual monitoring. Dosimeter characteristics as repeatability, linearity and directional response were of particular interest. As a result of the tests, technical improvements are suggested to extent systems measuring capabilities in order to meet new standards. Possibilities of its use in different fields of dosimetry are discussed, where quick in field measurements of high doses is required as for example in medicine or in civil protection motivated by the new threads of terrorist attacks. (author)

  13. Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method

    Science.gov (United States)

    McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A.; Purdie, Thomas G.

    2017-08-01

    Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment

  14. Single daily dosing of antibiotics: importance of in vitro killing rate, serum half-life, and protein binding.

    Science.gov (United States)

    Potel, G; Chau, N P; Pangon, B; Fantin, B; Vallois, J M; Faurisson, F; Carbon, C

    1991-10-01

    The relative importance of pharmacokinetic and pharmacodynamic parameters for the feasibility of a single daily dose (SDD) of antibiotics remains to be established. Therefore, we studied the relationship between in vitro bacteriological parameters (MIC, MBC, and killing rate [KR], defined as the reduction in the inoculum within 3 h), pharmacokinetic parameters (t1/2 and protein binding [PB], and in vivo antibacterial effect of a single antibiotic dose in an experimental rabbit model of Escherichia coli endocarditis. Nine antibiotics were investigated: two aminoglycosides, two quinolones, and five beta-lactams. For each drug, the minimal effective dose (MED) (in milligrams per kilogram) was defined as the lowest dose able to achieve a significant difference (P less than 0.05) of CFU in the vegetations in comparison with controls 24 h after a single intravenous injection. Aminoglycosides and quinolones had the lowest MEDs, followed by beta-lactams. Univariate regression analysis showed that KR was the major determinant of MED. A stepwise regression analysis showed that t1/2 significantly improved the predictive value of KR, while PB, MIC, and MBC did not. The final equation was MED = 1,586-238 KR-297 t1/2 (r = 0.90, P = 0.01). We concluded that the pharmacodynamic parameters (especially the high KR) of aminoglycosides and quinolones explained their low MEDs and might allow SDD. In contrast, the low KR of beta-lactams emphasized the critical importance of a long t1/2, as for ceftriaxone, allowing the use of this beta-lactam alone in SDD.

  15. The influence of parameters of A-type carbonated apatites synthesis on radiation dose response

    International Nuclear Information System (INIS)

    Oliveira, Liana Macedo de; Lopes, Ricardo Tadeu

    2000-01-01

    The aim of this work is the investigation of dose response of A-type carbonated apatites prepared in different conditions. Irradiated samples prepared with carbonate content of 1.45 to 4.84% are studied by using electron paramagnetic resonance (EPR). The EPR spectra are mainly constituted of lines associated to axial CO 2 - species (g perp = 2.0028 and g // = 1.9973) and CO 3 - species (g 1 = 2,0170, g 2 = 2,0090 e g 3 = 2,0041). The production of CO 2 - species on gamma irradiation depends on the carbonate concentration and the hydroxyapatite stoichiometry. The lowest dose detection limit was achieved with stoichiometric samples and carbonate content around of 3.7%. (author)

  16. Quantitative relations between beta-gamma mixed-field dosimeter responses and dose-equivalent conversion factors according to the testing standard

    International Nuclear Information System (INIS)

    Gupta, V.P.

    1982-08-01

    The conventional two-element personnel dosimeters, usually having two thick TLD (thermoluminescent dosimetry) ribbons, are used extensively for radiation protection dosimetry. Many of these dosimeters are used for the measurement of beta and gamma radiation doses received in mixed beta-gamma fields. Severe limitations exist, however, on the relative magnitudes and energies of these fields that may be measured simultaneously. Moreover, due to a well-known energy dependence of these dosimeters, particularly for the beta-radiations, systematic errors will occur whenever the differences in workplaces and calibration radiation energies exist. A simple mathematical approach is presented to estimate the deep and shallow dose equivalent values at different energies for such dosimeters. The formulae correlate the dosimeter responses and dose equivalent conversion factors at different energies by taking into account the guidelines of the adopted ANSI Standard N13.11 and the dosimetry practices followed by most dosimeter processors. This standard is to be used in a mandatory testing program in the United States

  17. The effects of chronic, low doses of Ra-226 on cultured fish and human cells

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Xiaopei; Seymour, Colin; Mothersill, Carmel, E-mail: mothers@mcmaster.ca

    2016-07-15

    Purpose: To determine the chronic low-dose radiation effects caused by α-particle radiation from {sup 226}Ra over multiple cell generations in CHSE/F fish cells and HaCaT human cells. Methods: CHSE/F cells and HaCaT cells were cultured in medium containing {sup 226}Ra to deliver the chronic low-dose α-particle radiation. Clonogenic assay was used to test the clonogenic survival fractions of cells with or without being exposed to radiation from {sup 226}Ra. Results: The chronic low-dose radiation from {sup 226}Ra does have effects on the clonogenic survival of CHSE/F cells and HaCaT cells. When CHSE/F cells were cultured in {sup 226}Ra-medium over 9 passages for about 134 days, the clonogenic surviving fractions for cells irradiated at dose rates ranging from 0.00066 to 0.66 mGy/d were significantly lower than that of cells sham irradiated. For HaCaT cells grown in medium containing the same range of {sup 226}Ra activity, the clonogenic surviving fraction decreased at first and reached the lowest value at about 42 days (8 passages). After that, the clonogenic survival began to increase, and was significantly higher than that of control cells by the end of the experimental period. Conclusion: The chronic, low-dose high LET radiation from {sup 226}Ra can influence the clonogenic survival of irradiated cells. CHSE/F cells were sensitized by the radiation, and HaCaT cells were initially sensitized but later appeared to be adapted. The results could have implications for determining risk from chronic versus acute exposures to radium. - Highlights: • Cells were exposed to chronic low-dose α-radiation from {sup 226}Ra in medium with {sup 226}Ra. • The clonogenic survival of CHSE/F cells decreased when exposed to {sup 226}Ra for 134 days. • The clonogenic survival of HaCaT cells decreased at first and then increased. • The doubling time of both cells were not affected by this kind of radiation.

  18. Lowest-order corrections to the RPA polarizability and GW self-energy of a semiconducting wire

    NARCIS (Netherlands)

    Groot, de H.J.; Ummels, R.T.M.; Bobbert, P.A.; van Haeringen, W.

    1996-01-01

    We present the results of the addition of lowest-order vertex and self-consistency corrections to the RPA polarizability and the GW self-energy for a semiconducting wire. It is found that, when starting from a local density approximation zeroth-order Green function and systematically including these

  19. Vertical Distribution and Estimated Doses from Artificial Radionuclides in Soil Samples around the Chernobyl Nuclear Power Plant and the Semipalatinsk Nuclear Testing Site

    Science.gov (United States)

    Taira, Yasuyuki; Hayashida, Naomi; Tsuchiya, Rimi; Yamaguchi, Hitoshi; Takahashi, Jumpei; Kazlovsky, Alexander; Urazalin, Marat; Rakhypbekov, Tolebay; Yamashita, Shunichi; Takamura, Noboru

    2013-01-01

    For the current on-site evaluation of the environmental contamination and contributory external exposure after the accident at the Chernobyl Nuclear Power Plant (CNPP) and the nuclear tests at the Semipalatinsk Nuclear Testing Site (SNTS), the concentrations of artificial radionuclides in soil samples from each area were analyzed by gamma spectrometry. Four artificial radionuclides (241Am, 134Cs, 137Cs, and 60Co) were detected in surface soil around CNPP, whereas seven artificial radionuclides (241Am, 57Co, 137Cs, 95Zr, 95Nb, 58Co, and 60Co) were detected in surface soil around SNTS. Effective doses around CNPP were over the public dose limit of 1 mSv/y (International Commission on Radiological Protection, 1991). These levels in a contaminated area 12 km from Unit 4 were high, whereas levels in a decontaminated area 12 km from Unit 4 and another contaminated area 15 km from Unit 4 were comparatively low. On the other hand, the effective doses around SNTS were below the public dose limit. These findings suggest that the environmental contamination and effective doses on the ground definitely decrease with decontamination such as removing surface soil, although the effective doses of the sampling points around CNPP in the present study were all over the public dose limit. Thus, the remediation of soil as a countermeasure could be an extremely effective method not only for areas around CNPP and SNTS but also for areas around the Fukushima Dai-ichi Nuclear Power Plant (FNPP), and external exposure levels will be certainly reduced. Long-term follow-up of environmental monitoring around CNPP, SNTS, and FNPP, as well as evaluation of the health effects in the population residing around these areas, could contribute to radiation safety and reduce unnecessary exposure to the public. PMID:23469013

  20. Vertical distribution and estimated doses from artificial radionuclides in soil samples around the Chernobyl nuclear power plant and the Semipalatinsk nuclear testing site.

    Directory of Open Access Journals (Sweden)

    Yasuyuki Taira

    Full Text Available For the current on-site evaluation of the environmental contamination and contributory external exposure after the accident at the Chernobyl Nuclear Power Plant (CNPP and the nuclear tests at the Semipalatinsk Nuclear Testing Site (SNTS, the concentrations of artificial radionuclides in soil samples from each area were analyzed by gamma spectrometry. Four artificial radionuclides ((241Am, (134Cs, (137Cs, and (60Co were detected in surface soil around CNPP, whereas seven artificial radionuclides ((241Am, (57Co, (137Cs, (95Zr, (95Nb, (58Co, and (60Co were detected in surface soil around SNTS. Effective doses around CNPP were over the public dose limit of 1 mSv/y (International Commission on Radiological Protection, 1991. These levels in a contaminated area 12 km from Unit 4 were high, whereas levels in a decontaminated area 12 km from Unit 4 and another contaminated area 15 km from Unit 4 were comparatively low. On the other hand, the effective doses around SNTS were below the public dose limit. These findings suggest that the environmental contamination and effective doses on the ground definitely decrease with decontamination such as removing surface soil, although the effective doses of the sampling points around CNPP in the present study were all over the public dose limit. Thus, the remediation of soil as a countermeasure could be an extremely effective method not only for areas around CNPP and SNTS but also for areas around the Fukushima Dai-ichi Nuclear Power Plant (FNPP, and external exposure levels will be certainly reduced. Long-term follow-up of environmental monitoring around CNPP, SNTS, and FNPP, as well as evaluation of the health effects in the population residing around these areas, could contribute to radiation safety and reduce unnecessary exposure to the public.

  1. Vertical distribution and estimated doses from artificial radionuclides in soil samples around the Chernobyl nuclear power plant and the Semipalatinsk nuclear testing site.

    Science.gov (United States)

    Taira, Yasuyuki; Hayashida, Naomi; Tsuchiya, Rimi; Yamaguchi, Hitoshi; Takahashi, Jumpei; Kazlovsky, Alexander; Urazalin, Marat; Rakhypbekov, Tolebay; Yamashita, Shunichi; Takamura, Noboru

    2013-01-01

    For the current on-site evaluation of the environmental contamination and contributory external exposure after the accident at the Chernobyl Nuclear Power Plant (CNPP) and the nuclear tests at the Semipalatinsk Nuclear Testing Site (SNTS), the concentrations of artificial radionuclides in soil samples from each area were analyzed by gamma spectrometry. Four artificial radionuclides ((241)Am, (134)Cs, (137)Cs, and (60)Co) were detected in surface soil around CNPP, whereas seven artificial radionuclides ((241)Am, (57)Co, (137)Cs, (95)Zr, (95)Nb, (58)Co, and (60)Co) were detected in surface soil around SNTS. Effective doses around CNPP were over the public dose limit of 1 mSv/y (International Commission on Radiological Protection, 1991). These levels in a contaminated area 12 km from Unit 4 were high, whereas levels in a decontaminated area 12 km from Unit 4 and another contaminated area 15 km from Unit 4 were comparatively low. On the other hand, the effective doses around SNTS were below the public dose limit. These findings suggest that the environmental contamination and effective doses on the ground definitely decrease with decontamination such as removing surface soil, although the effective doses of the sampling points around CNPP in the present study were all over the public dose limit. Thus, the remediation of soil as a countermeasure could be an extremely effective method not only for areas around CNPP and SNTS but also for areas around the Fukushima Dai-ichi Nuclear Power Plant (FNPP), and external exposure levels will be certainly reduced. Long-term follow-up of environmental monitoring around CNPP, SNTS, and FNPP, as well as evaluation of the health effects in the population residing around these areas, could contribute to radiation safety and reduce unnecessary exposure to the public.

  2. Total dose and dose rate radiation characterization of EPI-CMOS radiation hardened memory and microprocessor devices

    International Nuclear Information System (INIS)

    Gingerich, B.L.; Hermsen, J.M.; Lee, J.C.; Schroeder, J.E.

    1984-01-01

    The process, circuit discription, and total dose radiation characteristics are presented for two second generation hardened 4K EPI-CMOS RAMs and a first generation 80C85 microprocessor. Total dose radiation performance is presented to 10M rad-Si and effects of biasing and operating conditions are discussed. The dose rate sensitivity of the 4K RAMs is also presented along with single event upset (SEU) test data

  3. Effects of secondary containment air cleanup system leakage on the accident offsite dose as determined during preop tests of the Sequoyah Nuclear Plant

    International Nuclear Information System (INIS)

    Klaes, L.J.; Nass, S.A.; Proctor, L.D.

    1981-01-01

    The Sequoyah Nuclear Plant has two secondary containments. One is the annular region between the primary containment and the shield building surrounding the primary containment. The second is the auxiliary building secondary containment enclosure which is potentially subject to direct airborne radioactivity. Two air cleanup systems are provided to serve these areas. The emergency gas treatment system (EGTS) serves the annulus between the primary containment and the shield building, and the auxiliary building gas treatment system (ABGTS) serves the area inside of the auxiliary building secondary containment enclosure. The major function served by these air cleanup systems is that of controlling and processing airborne contamination released in these areas during any accident up to a design basis accident. This is accomplished by (1) creating a negative pressure in the areas served to ensure that no unprocessed air is released to the atmosphere, (2) providing filtration units to process all air exhausted from the secondary containment spaces, and (3) providing a low-leakage enclosure to limit exhaust flows. Offsite dose effects due to secondary containment release rates, bypass leakage, and duct and damper leakages are presented and parameter variations are considered. For the EGTS, a recirculation system, the most important parameter is the total inleakage of the system which causes an increase in both whole body (gamma) and thyroid (iodine) doses. For the ABGTS, a once-through system, the most important paramter is the inleakage which bypasses the filters resulting in an increase in the thyroid dose only. Actual preoperational test data are utilized. Problems encountered during the preop test are summarized. Solutions incorporated to bring the EGTS and ABGTS air cleanup systems within the test acceptance criteria required to meet offsite dose limitations are discussed and the resultant calculated offsite dose is presented

  4. Degeneracy of the lowest Landau level and suq(2) on the Poincare half plane

    International Nuclear Information System (INIS)

    Jellal, A.

    2000-01-01

    It is shown that the presence of the quantum group symmetry su q (2) in the quantum Hall effect on the Poincare upper half plane the degeneracy of the lowest Landau level. It is also shown that the relation between the degeneracy and the cyclic representation of su q (2) appears in accordance with q being a kth root of unity. (Authors)

  5. Low-dose computed tomography to detect body-packing in an animal model

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, M.H., E-mail: martin.maurer@charite.de [Klinik fuer Strahlenheilkunde, Charite - Universitaetsmedizin, Berlin (Germany); Niehues, S.M.; Schnapauff, D.; Grieser, C.; Rothe, J.H. [Klinik fuer Strahlenheilkunde, Charite - Universitaetsmedizin, Berlin (Germany); Waldmueller, D. [Bildungs- und Wissenschaftszentrum der Bundesfinanzverwaltung, Berlin (Germany); Chopra, S.S. [Klinik fuer Allgemein-, Viszeral- und Transplantationschirurgie, Charite - Universitaetsmedizin, Berlin (Germany); Hamm, B.; Denecke, T. [Klinik fuer Strahlenheilkunde, Charite - Universitaetsmedizin, Berlin (Germany)

    2011-05-15

    Objective: To assess the possible extent of dose reduction for low-dose computed tomography (CT) in the detection of body-packing (ingested drug packets) as an alternative to plain radiographs in an animal model. Materials and methods: Twelve packets containing cocaine (purity >80%) were introduced into the intestine of an experimental animal (crossbred pig), which was then repeatedly examined by abdominal CT with stepwise dose reduction (tube voltage, 80 kV; tube current, 10-350 mA). Three blinded readers independently evaluated the CT datasets starting with the lowest tube current and noted the numbers of packets detected at the different tube currents used. In addition, 1 experienced reader determined the number of packets detectable on plain abdominal radiographs and ultrasound. Results: The threshold for correct identification of all 12 drug packets was 100 mA for reader 1 and 125 mA for readers 2 and 3. Above these thresholds all 3 readers consistently identified all 12 packets. The effective dose of a low-dose CT scan with 125 mA (including scout view) was 1.0 mSv, which was below that of 2 conventional abdominal radiographs (1.2 mSv). The reader interpreting the conventional radiographs identified a total of 9 drug packets and detected 8 packets by abdominal ultrasound. Conclusions: Extensive dose reduction makes low-dose CT a valuable alternative imaging modality for the examination of suspected body-packers and might replace conventional abdominal radiographs as the first-line imaging modality.

  6. Estimation of effective dose and lifetime attributable risk from multiple head CT scans in ventriculoperitoneal shunted children

    International Nuclear Information System (INIS)

    Aw-Zoretic, J.; Seth, D.; Katzman, G.; Sammet, S.

    2014-01-01

    Purpose: The purpose of this review is to determine the averaged effective dose and lifetime attributable risk factor from multiple head computed tomography (CT) dose data on children with ventriculoperitoneal shunts (VPS). Method and materials: A total of 422 paediatric head CT exams were found between October 2008 and January 2011 and retrospectively reviewed. The CT dose data was weighted with the latest IRCP 103 conversion factor to obtain the effective dose per study and the averaged effective dose was calculated. Estimates of the lifetime attributable risk were also calculated from the averaged effective dose using a conversion factor from the latest BEIR VII report. Results: Our study found the highest effective doses in neonates and the lowest effective doses were observed in the 10–18 years age group. We estimated a 0.007% potential increase risk in neonates and 0.001% potential increased risk in teenagers over the base risk. Conclusion: Multiple head CTs in children equates to a slight potential increase risk in lifetime attributable risk over the baseline risk for cancer, slightly higher in neonates relative to teenagers. The potential risks versus clinical benefit must be assessed

  7. Patient and staff doses and relationships between them in fluoroscopically guided procedures

    International Nuclear Information System (INIS)

    Avramova-Cholakova, S.; Christova-Popova, Y.; Sagorska, A.

    2015-01-01

    Full text: Medical exposure has the main contribution to man-made sources of exposures to the population in developed countries. Fluoroscopically guided procedures in interventional cardiology, gastroenterology, urology, orthopaedics and others may be related to high doses to both patients and staff. The main risk for both groups is the radiation carcinogenesis and it is increasing with dose. However deterministic effects are also possible: severe patient skin injuries occur sometimes. There are such cases in Bulgarian radiological practice. For the medical staff, involved in the procedures, radiation induced cataract is observed occasionally. Learning objective: In many cases there is direct correlation between patient and staff doses. Several simple rules must be observed in order to decrease exposure. Rules related to patient: Patient dose (dose-area product (DAP), fluoroscopy time, number of series,number of images) should be recorded for every patient; The patient should be positioned as far away as possible from the x-ray tube and as closer as possible to the image intensifier/digital image receptor; Fluoroscopy time should be minimized; Pulsed fluoroscopy with the lowest dose rate and the lowest frame rate providing acceptable image quality should be used; Different skin areas should be exposed in different projections; Oblique projections increase the dose - they should be avoided; Magnification also increases the dose several times and should be avoided; The acquisition mode should be avoided; it delivers dozens of times higher doses. Minimal number of frames and cine runs should be used. Use of “last image hold” is encouraged; The x-ray beam should be collimated to the area of interest. Rules related to staff: The staff receives scattered radiation from patient’s body. Every measure to decrease patient’s dose decreases staff dose as well; Every available protective device should be used (lead apron, thyroid collar, lead glasses, screens). They

  8. Dose rate effects of low-LET ionizing radiation on fish cells

    Energy Technology Data Exchange (ETDEWEB)

    Vo, Nguyen T.K. [McMaster University, Radiation Sciences Program, School of Graduate and Postdoctoral Studies, Hamilton, ON (Canada); Seymour, Colin B.; Mothersill, Carmel E. [McMaster University, Radiation Sciences Program, School of Graduate and Postdoctoral Studies, Hamilton, ON (Canada); McMaster University, Department of Biology, Hamilton, ON (Canada)

    2017-11-15

    Radiobiological responses of a highly clonogenic fish cell line, eelB, to low-LET ionizing radiation and effects of dose rates were studied. In acute exposure to 0.1-12 Gy of gamma rays, eelB's cell survival curve displayed a linear-quadratic (LQ) relationship. In the LQ model, α, β, and α/β ratio were 0.0024, 0.037, and 0.065, respectively; for the first time that these values were reported for fish cells. In the multi-target model, n, D{sub o}, and D{sub q} values were determined to be 4.42, 2.16, and 3.21 Gy, respectively, and were the smallest among fish cell lines being examined to date. The mitochondrial potential response to gamma radiation in eelB cells was at least biphasic: mitochondria hyperpolarized 2 h and then depolarized 5 h post-irradiation. Upon receiving gamma rays with a total dose of 5 Gy, dose rates (ranging between 83 and 1366 mGy/min) had different effects on the clonogenic survival but not the mitochondrial potential. The clonogenic survival was significantly higher at the lowest dose rate of 83 mGy/min than at the other higher dose rates. Upon continuous irradiation with beta particles from tritium at 0.5, 5, 50, and 500 mGy/day for 7 days, mitochondria significantly depolarized at the three higher dose rates. Clearly, dose rates had differential effects on the clonogenic survival of and mitochondrial membrane potential in fish cells. (orig.)

  9. Cytogenetic dose-response and adaptive response in cells of ungulate species exposed to ionizing radiation

    International Nuclear Information System (INIS)

    Ulsh, B.A.; Miller, S.M.; Mallory, F.F.; Mitchel, R.E.J.; Morrison, D.P.; Boreham, D.R.

    2004-01-01

    In the studies reported here, the micronucleus assay, a common cytogenetic technique, was used to examine the dose-responses in fibroblasts from three ungulate species (white-tailed deer, woodland caribou, and Indian muntjac) exposed to high doses of ionizing radiation (1-4 Gy of 60 Co gamma radiation). This assay was also used to examine the effects of exposure to low doses (1-100 mGy) typical of what these species experience in a year from natural and anthropogenic environmental sources. An adaptive response, defined as the induction of resistance to a stressor by a prior exposure to a small 'adapting' stress, was observed after exposure to low doses. This work indicates that very small doses are protective for the endpoint examined. The same level of protection was seen at all adapting doses, including 1 radiation track per cell, the lowest possible cellular dose. These results are consistent with other studies in a wide variety of organisms that demonstrate a protective effect of low doses at both cellular and whole-organism levels. This implies that environmental regulations predicated on the idea that even the smallest dose of radiation carries a quantifiable risk of direct adverse consequences to the exposed organism require further examination. Cytogenetic assays provide affordable and feasible biological effects-based alternatives that are more biologically relevant than traditional contaminant concentration-based radioecological risk assessment

  10. Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kaasalainen, Touko; Lampinen, Anniina [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); University of Helsinki, Department of Physics, Helsinki (Finland); Palmu, Kirsi [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); School of Science, Aalto University, Department of Biomedical Engineering and Computational Science, Helsinki (Finland); Reijonen, Vappu; Kortesniemi, Mika [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); Leikola, Junnu [University of Helsinki and Helsinki University Hospital, Department of Plastic Surgery, Helsinki (Finland); Kivisaari, Riku [University of Helsinki and Helsinki University Hospital, Department of Neurosurgery, Helsinki (Finland)

    2015-09-15

    Medical professionals need to exercise particular caution when developing CT scanning protocols for children who require multiple CT studies, such as those with craniosynostosis. To evaluate the utility of ultra-low-dose CT protocols with model-based iterative reconstruction techniques for craniosynostosis imaging. We scanned two pediatric anthropomorphic phantoms with a 64-slice CT scanner using different low-dose protocols for craniosynostosis. We measured organ doses in the head region with metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters. Numerical simulations served to estimate organ and effective doses. We objectively and subjectively evaluated the quality of images produced by adaptive statistical iterative reconstruction (ASiR) 30%, ASiR 50% and Veo (all by GE Healthcare, Waukesha, WI). Image noise and contrast were determined for different tissues. Mean organ dose with the newborn phantom was decreased up to 83% compared to the routine protocol when using ultra-low-dose scanning settings. Similarly, for the 5-year phantom the greatest radiation dose reduction was 88%. The numerical simulations supported the findings with MOSFET measurements. The image quality remained adequate with Veo reconstruction, even at the lowest dose level. Craniosynostosis CT with model-based iterative reconstruction could be performed with a 20-μSv effective dose, corresponding to the radiation exposure of plain skull radiography, without compromising required image quality. (orig.)

  11. Effect of Exposure Dose on Ichthyophonus Prevalence and Infection Intensity in Experimentally Infected Rainbow Trout, Oncorhynchus mykiss.

    Science.gov (United States)

    Kocan, Richard; LaPatra, Scott

    2016-02-01

    This study describes the effect of increasing exposure dose on Ichthyophonus prevalence and infection intensity in experimentally infected rainbow trout, Oncorhynchus mykiss. Specific-pathogen free trout were exposed per os to increasing numbers of Ichthyophonus schizonts obtained from naturally infected donor fish, then sampled after 30 and 60 days post-exposure. Both in vitro explant culture and histology revealed that as the number of schizonts per dose increased there was a proportionate increase in the number of infected fish, as well as an increase in the number of infected organs; parasite density in individual infected organs also increased with dose. Explant culture revealed that all fish exposed to the highest dose (≥2,080 schizonts) became infected, while only 67% of those exposed to the intermediate dose (1,040-1,153 schizonts) were Ichthyophonus-positive after 60 days; Ichthyophonus was not detected in fish exposed to the 2 lowest doses (≤280 schizonts). Histologic examination of individual infected organs also revealed increasing infection prevalence and parasite density in response to exposure to increasing numbers of Ichthyophonus schizonts.

  12. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    Science.gov (United States)

    Azorín, C.; Azorín, J.; Aguirre, F.; Rivera, T.

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations.

  13. Dose measurements in intraoral radiography using thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Azorín, C; Rivera, T; Azorín, J; Aguirre, F

    2015-01-01

    The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations

  14. Dosing of U-100 insulin and associated outcomes among Medicare enrollees with type 1 or type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Eby EL

    2015-06-01

    Full Text Available Elizabeth L Eby,1 Kate Van Brunt,2 Cynthia Brusko,3 Bradley Curtis,4 Maureen J Lage5 1Global Patient Outcomes and Real World Evidence, Eli Lilly and Co., Indianapolis IN USA; 2Eli Lilly and Co., Windlesham, UK; 3Lilly USA, LLC, Indianapolis, IN, USA; 4Eli Lilly and Co., Indianapolis, IN, USA; 5HealthMetrics Outcomes Research, LLC, Bonita Springs, FL, USA Objective: To examine costs, resource utilization, adherence, and hypoglycemic events among various doses of U-100 insulin regimens among elderly patients (age ≥65 years diagnosed with diabetes.Methods: Truven Health Analytics Medicare databases from January 1, 2008 through December 31, 2011 were utilized. General linear models with a gamma distribution and log link were used to examine costs, while logistic and negative binomial regressions were used to examine resource utilization and hypoglycemic events. Analyses controlled for patient characteristics, pre-period comorbidities, general health, and use of antidiabetic medications as well as index dose of insulin.Results: All-cause inpatient, emergency room, and outpatients costs, as well as diabetes-related inpatient costs, were highest among individuals who were treated with an index dose of 10–100 units/day followed by >300 units/day, while drug costs and total costs generally increased as index dosage increased. Resource utilization generally followed the same pattern as costs, with number of office visits increasing as the dose increased and the highest hospital length of stay, number of hospitalizations, number of emergency room visits, and number of diabetes-related hospitalizations were generally highest among those in the lowest and highest index dose cohorts. Compared to patients who initiated with an index dose of 10–100 units/day, all other patients were significantly less likely to achieve an adherence threshold of 80% based upon index dose range, and while those with an index dose of >100–150 units/day were

  15. Thresholds of Toxicological Concern - Setting a threshold for testing below which there is little concern.

    Science.gov (United States)

    Hartung, Thomas

    2017-01-01

    Low dose, low risk; very low dose, no real risk. Setting a pragmatic threshold below which concerns become negligible is the purpose of thresholds of toxicological concern (TTC). The idea is that such threshold values do not need to be established for each and every chemical based on experimental data, but that by analyzing the distribution of lowest or no-effect doses of many chemicals, a TTC can be defined - typically using the 5th percentile of this distribution and lowering it by an uncertainty factor of, e.g., 100. In doing so, TTC aims to compare exposure information (dose) with a threshold below which any hazard manifestation is very unlikely to occur. The history and current developments of this concept are reviewed and the application of TTC for different regulated products and their hazards is discussed. TTC lends itself as a pragmatic filter to deprioritize testing needs whenever real-life exposures are much lower than levels where hazard manifestation would be expected, a situation that is called "negligible exposure" in the REACH legislation, though the TTC concept has not been fully incorporated in its implementation (yet). Other areas and regulations - especially in the food sector and for pharmaceutical impurities - are more proactive. Large, curated databases on toxic effects of chemicals provide us with the opportunity to set TTC for many hazards and substance classes and thus offer a precautionary second tier for risk assessments if hazard cannot be excluded. This allows focusing testing efforts better on relevant exposures to chemicals.

  16. Charge-Transfer Dynamics in the Lowest Excited State of a Pentacene–Fullerene Complex: Implications for Organic Solar Cells

    KAUST Repository

    Joseph, Saju

    2017-10-02

    We characterize the dynamic nature of the lowest excited state in a pentacene/C60 complex on the femtosecond time scale, via a combination of ab initio molecular dynamics and time-dependent density functional theory. We analyze the correlations between the molecular vibrations of the complex and the oscillations in the electron-transfer character of its lowest excited state, which point to vibration-induced coherences between the (pentacene-based) local-excitation (LE) state and the complex charge-transfer (CT) state. We discuss the implications of our results on this model system for the exciton-dissociation process in organic solar cells.

  17. The behavior of rats irradiated with a sublethal single dose of γ-rays on the region of head in open field test

    International Nuclear Information System (INIS)

    Smajda, B.; Kiskova, J.; Kereskenyiova, E.

    2004-01-01

    The goal of this work was to establish the effects of the irradiation of head in laboratory rats on some forms of naturalistic behavior in the open field test. During a 5-day control period behavioral parameters reflecting motory and explorative activity, as well as anxiousness of animals (6 parameters in total) were followed daily in 20 male Sprague-Dowley rats in an open field test lasting 5 minutes. Fourteen animals were repeatedly tested after irradiation of head with a single dose of 10 Gy of gamma rays. The results showed statistically significant depression of motory and explorative activities during the first 3 days after irradiation in comparison with the control period. The anxiousness of animals was decreased, too. Novelty habituation was observed only in non-irradiated animals. Based on these results it is possible to presume, that the applied dose of ionizing radiation was able to influence the brain centers involved in control of naturalistic behavioral functions connected with response to new environment in rats. (authors)

  18. Effects of the antimicrobial peptide protegrine 1 on sperm viability and bacterial load of boar seminal doses.

    Science.gov (United States)

    Sancho, S; Briz, M; Yeste, M; Bonet, S; Bussalleu, E

    2017-10-01

    The presence of bacteria adversely affects boar sperm quality of seminal doses intended for artificial insemination. Currently, the most common measure to prevent bacteriospermia is the addition of antibiotics in semen extenders; however, mounting evidence shows that microbial resistance exists. A promising alternative to replace antibiotics are antimicrobial peptides. In this study, the effects of the antimicrobial peptide protegrine 1 (PG1) on the sperm viability and bacterial load of boar seminal doses were evaluated. Three different concentrations of PG1 (2.5, 25 and 100 μg/ml) were tested over a storing period of 10 days at 17°C. Sperm viability was analysed by fluorescence microscopy (SYBR14/propidium iodide), and bacterial load was assessed by plating 100 μl of each sample in Luria-Bertani medium and incubated at 37°C for 72 hr under aerobic conditions. Protegrine 1 was effective in controlling the bacterial load in all the assessed concentrations (p < .05), reaching the lowest values at the highest concentrations of the antimicrobial peptide. Nevertheless, sperm viability was significantly (p < .05) reduced by all tested concentrations of this peptide, the most cytotoxic effects being observed at the highest PG1 concentrations. Despite these results, the use of PG1 as an alternative to antibiotics cannot be totally discarded, as further studies using the truncated form of this peptide are needed. © 2017 Blackwell Verlag GmbH.

  19. Consumer Airfare Report: Table 5 - Detailed Fare Information For Highest and Lowest Fare Markets Under 750 Miles

    Data.gov (United States)

    Department of Transportation — Provides detailed fare information for highest and lowest fare markets under 750 miles. For a more complete explanation, please read the introductory information at...

  20. Excitation energy of the lowest 2+ and 3- levels in 32Mg and 146Gd

    International Nuclear Information System (INIS)

    Barranco, M.; Lombard, R.J.

    1978-06-01

    The excitation energy of the lowest 2 + and 3 - levels are calculated for neutron rich Mg-isotopes as well as for N=82 isotones. The calculations are made by assuming quadrupole-quadrupole and octupole-octupole forces. The quasi-particles energies and occupation numbers are taken from the energy density method

  1. How Effective Are Community College Remedial Math Courses for Students with the Lowest Math Skills?

    Science.gov (United States)

    Xu, Di; Dadgar, Mina

    2018-01-01

    Objective: This article examines the effectiveness of remediation for community college students who are identified as having the lowest skills in math. Method: We use transcript data from a state community college system and take advantage of a regression discontinuity design that compares statistically identical students who are assigned to the…

  2. Natural external radiation level and population dose in Hunan province

    International Nuclear Information System (INIS)

    1985-01-01

    A survey of the natural external radiation level in Hunan Province is reported. The measurements were performed with FD-71 scintillation radiometers. On the basis of measurements at about 1,600 locations, the contribution from cosmic radiation is found to be 3.0 x 10 -8 Gy.h -1 , and the average absorbed dose rates in air from terrestrial γ-radiation for outdoors, indoors and roads are determined to be 9.2, 13.1 and 9.0 x 10 -8 Gy.h -1 , respectively. The γ-radiation indoors is markedly higher than that outdoors by a factor of 1.42. The lowest γ-radiation level is found in the sedimentary plain around Donting Lake, while the highest absorbed dose rates in air from terrestrial radiation are observed in some areas with exposed granites. The indoor γ-radiation in brick houses is markedly higher than that in wooden houses. Tarred roads have evidently lower radiation level than sand-gravel roads or concrete roads. The annual effective dose equivalents to the population from cosmic and terrestrial sources are 0.256 and 0.756 mSv, respectively, with a total value of 1.012 mSv

  3. Medium doses of daily vitamin D decrease falls and higher doses of daily vitamin D3 increase falls: A randomized clinical trial.

    Science.gov (United States)

    Smith, Lynette M; Gallagher, J Christopher; Suiter, Corinna

    2017-10-01

    Falls are a serious health problem in the aging population. Because low levels of vitamin D have been associated with increased fall rates, many trials have been performed with vitamin D; two meta-analyses showed either a small effect or no effect of vitamin D on falls. We conducted a study of the effect of vitamin D on serum 25 hydroxyvitamin D (25OHD) and data on falls was collected as a secondary outcome. In a 12-month double blind randomized placebo trial, elderly women, mean age 66 years, were randomized to one of seven daily oral doses of vitamin D or placebo. The main inclusion criterion for study was a baseline serum 25OHDvitamin D on falls followed a U-shaped curve whether analyzed by dose or serum 25OHD levels. There was no decrease in falls on low vitamin D doses 400, 800 IU, a significant decrease on medium doses 1600, 2400,3200 IU (p=0.020) and no decrease on high doses 4000, 4800 IU compared to placebo (p=0.55). When compared to 12-month serum 25OHD quintiles, the faller rate was 60% in the lowest quintile <25ng/ml (<50nmol/L), 21% in the low middle quintile 32-38ng/ml (80-95nmo/L), 72% in the high middle quintile 38-46ng/ml (95-115nmo/L) and 45% in the highest quintile 46-66ng/ml (115-165nmol/L). In the subgroup with a fall history, fall rates were 68% on low dose, 27% on medium doses and 100% on higher doses. Fall rates on high doses were increased compared to medium doses (Odds Ratio 5.6.95% CI: 2.1-14.8). In summary, the maximum decrease in falls corresponds to a 12- month serum 25OHD of 32-38ng/ml (80-95nmol/L) and faller rates increase as serum 25OHD exceed 40-45ng/ml (100-112.5nmol/L). The Tolerable upper limit (TUL) recently increased in 2010 from 2000 to 4000 IU/day may need to be reduced in elderly women especially in those with a fall history. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Radiation retinopathy after external-beam irradiation: Analysis of time-dose factors

    International Nuclear Information System (INIS)

    Parsons, J.T.; Bova, F.J.; Mendenhall, W.M.

    1994-01-01

    To investigate the risk of radiation-induced retinopathy according to total radiation dose and fraction size, based on both retorspective and prospectively collected data. Between October 1964 and May 1989, 68 retinae in 64 patients received fractionated external-beam irradiation during the treatment of primary extracranial head and neck tumors. All patients had a minimum of 3 years of ophthalmologic follow-up (range, 3 to 26 years; mean, 9 years; median, 8 years). Twenty-seven eyes in 26 patients developed radiation retinopathy resulting in visual acuity of 20/200 or worse. The mean and median times to the onset of symptoms attributable to retinal ischemia were 2.8 and 2.5 years, respectively. Fourteen of the injured eyes developed rubeosis iridis and/or neovascular glaucoma. Radiation retinopathy was not observed at doses below 45 Gy, but increased steadily in incidence at doses ≥45Gy. In the range of doses between 45 and 55 Gy, there was an increased risk of injury among patients who received doses per fraction of ≥1.9Gy (p - .09). There was also a trend toward increased risk of injury among patients who received chemotherapy (two of two vs. four of ten in the 45-51 Gy range; p - .23). The lowest dose associated with retinopathy was 45 Gy delivered to a diabetic patient by twice-a-day fractionation. The data did not suggest an increased risk of radiation retinopathy with increasing age. The current study suggests the importance of total dose as well as dose per fraction, and adds support to a small body of literature suggesting that patients with diabetes mellitus or who receive chemotherapy are at increased risk of injury. A sigmoid dose-response curve is constructed from our current data and data from the literature. 36 refs., 5 figs., 4 tabs

  5. The dose dependence of fracture toughness Of F82H steel

    Energy Technology Data Exchange (ETDEWEB)

    Sokolov, M. [Oak Ridge National Laboratory, Materials Science and Technology Div., TN (United States); Tanigawa, H.; Ando, M.; Shiba, K. [Japan Atomic Energy Agency, Tokai-mura, Naga-gun, Ibaraki-ken (Japan); Odette, G. [UCSB, Santa-Barbara, Dept. of Mechanical Engineering UCSB, AK (United States); Hirose, T. [Blanket Engineering Group, Japan Atomic Energy Agency, Naka, Ibaraki (Japan); Klueh, R.L. [Oak Ridge Noational Laboratory, TN (United States)

    2007-07-01

    Full text of publication follows: The ferritic-martensitic steel F82H is a primary candidate low-activation material for fusion applications, and it is being investigated in the joint U.S. Department of Energy-Japan Atomic Energy Agency. As a part of this program, several capsules containing fracture toughness specimens were irradiated in High-Flux Isotope Reactor. These specimens were irradiated to a wide range of doses from 3.5 to 25 dpa. The range of irradiation temperature was from 250 deg. C to 500 deg. C. This paper summarizes the changes in fracture toughness transition temperature and decrease in the ductile fracture toughness as result of various irradiation conditions. It is shown that in the 3.5 to 25 dpa dose range, irradiation temperature plays the key rote in determination of the shift of the transition temperature. Highest embrittlement observed at 250 deg.C and the lowest at 500 deg. C. At a given irradiation temperature, shift of the fracture toughness transition temperature increases slightly with dose within the studied dose range. It appears that main gain in transition temperature shift occurred during initial {approx}5 dpa of irradiation. The present data are compared to the available published trends. (authors)

  6. Estimating effective dose to pediatric patients undergoing interventional radiology procedures using anthropomorphic phantoms and MOSFET dosimeters.

    Science.gov (United States)

    Miksys, Nelson; Gordon, Christopher L; Thomas, Karen; Connolly, Bairbre L

    2010-05-01

    The purpose of this study was to estimate the effective doses received by pediatric patients during interventional radiology procedures and to present those doses in "look-up tables" standardized according to minute of fluoroscopy and frame of digital subtraction angiography (DSA). Organ doses were measured with metal oxide semiconductor field effect transistor (MOSFET) dosimeters inserted within three anthropomorphic phantoms, representing children at ages 1, 5, and 10 years, at locations corresponding to radiosensitive organs. The phantoms were exposed to mock interventional radiology procedures of the head, chest, and abdomen using posteroanterior and lateral geometries, varying magnification, and fluoroscopy or DSA exposures. Effective doses were calculated from organ doses recorded by the MOSFET dosimeters and are presented in look-up tables according to the different age groups. The largest effective dose burden for fluoroscopy was recorded for posteroanterior and lateral abdominal procedures (0.2-1.1 mSv/min of fluoroscopy), whereas procedures of the head resulted in the lowest effective doses (0.02-0.08 mSv/min of fluoroscopy). DSA exposures of the abdomen imparted higher doses (0.02-0.07 mSv/DSA frame) than did those involving the head and chest. Patient doses during interventional procedures vary significantly depending on the type of procedure. User-friendly look-up tables may provide a helpful tool for health care providers in estimating effective doses for an individual procedure.

  7. PA positioning significantly reduces testicular dose during sacroiliac joint radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mekis, Nejc [Faculty of Health Sciences, University of Ljubljana (Slovenia); Mc Entee, Mark F., E-mail: mark.mcentee@ucd.i [School of Medicine and Medical Science, University College Dublin 4 (Ireland); Stegnar, Peter [Jozef Stefan International Postgraduate School, Ljubljana (Slovenia)

    2010-11-15

    Radiation dose to the testes in the antero-posterior (AP) and postero-anterior (PA) projection of the sacroiliac joint (SIJ) was measured with and without a scrotal shield. Entrance surface dose, the dose received by the testicles and the dose area product (DAP) was used. DAP measurements revealed the dose received by the phantom in the PA position is 12.6% lower than the AP (p {<=} 0.009) with no statistically significant reduction in image quality (p {<=} 0.483). The dose received by the testes in the PA projection in SIJ imaging is 93.1% lower than the AP projection when not using protection (p {<=} 0.020) and 94.9% lower with protection (p {<=} 0.019). The dose received by the testicles was not changed by the use of a scrotal shield in the AP position (p {<=} 0.559); but was lowered by its use in the PA (p {<=} 0.058). Use of the PA projection in SIJ imaging significantly lowers, the dose received by the testes compared to the AP projection without significant loss of image quality.

  8. Mouse single oral dose toxicity test of bupleuri radix aqueous extracts.

    Science.gov (United States)

    Kim, Kyung-Hu; Gam, Cheol-Ou; Choi, Seong-Hun; Ku, Sae-Kwang

    2012-03-01

    The aim of this study was to evaluate the single oral dose toxicity of Bupleuri Radix (BR) aqueous extracts, it has been traditionally used as anti-inflammatory agent, in male and female mice. BR extracts (yield = 16.52%) was administered to female and male ICR mice as an oral dose of 2,000, 1,000 and 500 mg/kg (body weight) according to the recommendation of Korea Food and Drug Administration (KFDA) Guidelines. Animals were monitored for the mortality and changes in body weight, clinical signs and gross observation during 14 days after dosing, upon necropsy; organ weight and histopathology of 14 principal organs were examined. As the results, no BR extracts treatment related mortalities, clinical signs, changes on the body and organ weights, gross and histopathological observations against 14 principal organs were detected up to 2,000 mg/kg in both female and male mice, except for soft feces and related body weight decrease detected in male mice treated with 2,000 mg/kg. Therefore, LD50 (50% lethal dose) and approximate LD of BR aqueous extracts after single oral treatment in female and male mice were considered over 2000 mg/kg, respectively. Although it was also observed that the possibilities of digestive disorders, like soft feces when administered over 2,000 mg/kg of BR extracts in the present study, these possibilities of digestive disorders can be disregard in clinical use because they are transient in the highest dosages male only.

  9. Physicians' knowledge about radiation dose and possible risks of common medical tests: a survey in Iran

    International Nuclear Information System (INIS)

    Zakeri, Farideh; Mianji, Fereidoun; Shakeri, Mahsa; Rajabpour, Mohammad Reza; Farshidpour, Mohammad Reza

    2016-01-01

    Recent data suggest that knowledge of radiation exposures among physicians is inadequate. This study, therefore, aimed to evaluate their knowledge of the radiation doses their patients received and awareness of associated biological risks of radiation exposure. A questionnaire in multiple-choice format consisted of four sections with a total of 10 questions based on the literature review. A total of 136 questionnaires were returned from 69 general practitioners and 67 physicians in various specialties from 10 different hospitals in the capital city of Tehran, Iran. Fifty-four percent of general practitioners and twenty-five percent of specialties declared that they are not aware of biological risks of radiation exposure. Fifty-six percent of physicians did not know the correct definition of absorbed dose. Only 33% of physicians knew the dose exposure of a chest X-ray and only 31% knew the approximate doses of various procedures relative to a chest X-ray. Forty-seven percent of physicians incorrectly distinguished the stochastic effects of radiation from the deterministic effects, and thirty-eight of physicians did not know the organs of the body that are most sensitive to ionizing radiation. Only 23.5% of physicians were aware of the one in 2000 risk of induction of fatal carcinoma from computed tomography of the abdomen. Seventy-nine percent of physicians incorrectly underestimated the contribution of nuclear and radiological tests in exposure of an average person. The mean score of the specialties trended toward being more accurate than general practitioners (4.18 ± 1.28 vs. 3.89 ± 1.46, respectively, from a potential accurate total score of 9), but these differences were not statistically significant. Among specialists, orthopedics had the highest scores. The present study demonstrated the limited knowledge of radiation exposures among general practitioners and specialists and a need to improve their knowledge by means of targeted training and re

  10. Bilateral femoral head avascular necrosis with a very low dose of oral corticosteroid used for panhypopituitarism.

    Science.gov (United States)

    Dharmshaktu, Pramila; Aggarwal, Anshita; Dutta, Deep; Kulshreshtha, Bindu

    2016-01-13

    Avascular necrosis (AVN) of the femoral head is a rare complication related to glucocorticoid administration and traditionally has been associated with high doses and/or prolonged therapy. Occurrence of osteonecrosis with a physiological replacement dose of glucocorticoids has not been reported previously. We report a 38-year-old man with non-secreting pituitary adenoma who developed bilateral AVN while on a very small dose of oral prednisolone for secondary adrenal insufficiency after surgery for pituitary adenoma. The patient was switched to hydrocortisone. Zolindronic acid was administered and the patient underwent bilateral core decompressive surgery resulting in a reduction of hip pain and improvement. When last evaluated, 2 years after diagnosis of AVN, the patient was functionally independent, and was able to do his routine activities with mild pain. The report intends to highlight the occurrence of AVN of the femur even with a very small dose of prednisolone used for treatment of panhypopituitarism. Glucocorticoids may have to be continued in the lowest possible dose using the most physiological preparation such as hydrocortisone when stoppage is not possible. 2016 BMJ Publishing Group Ltd.

  11. Bilateral femoral head avascular necrosis with a very low dose of oral corticosteroid used for panhypopituitarism

    Science.gov (United States)

    Dharmshaktu, Pramila; Aggarwal, Anshita; Dutta, Deep; Kulshreshtha, Bindu

    2016-01-01

    Avascular necrosis (AVN) of the femoral head is a rare complication related to glucocorticoid administration and traditionally has been associated with high doses and/or prolonged therapy. Occurrence of osteonecrosis with a physiological replacement dose of glucocorticoids has not been reported previously. We report a 38-year-old man with non-secreting pituitary adenoma who developed bilateral AVN while on a very small dose of oral prednisolone for secondary adrenal insufficiency after surgery for pituitary adenoma. The patient was switched to hydrocortisone. Zolindronic acid was administered and the patient underwent bilateral core decompressive surgery resulting in a reduction of hip pain and improvement. When last evaluated, 2 years after diagnosis of AVN, the patient was functionally independent, and was able to do his routine activities with mild pain. The report intends to highlight the occurrence of AVN of the femur even with a very small dose of prednisolone used for treatment of panhypopituitarism. Glucocorticoids may have to be continued in the lowest possible dose using the most physiological preparation such as hydrocortisone when stoppage is not possible. PMID:26762348

  12. Dose profile in computed tomography chest scan; Perfil de dose em varredura de torax em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno B., E-mail: bbo@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Pos-graduacao em Ciencias e Tecnologia das Radiacoes, Minerais e Materiais; Mourao, Arnaldo P. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET/MG), Belo Horizonte, MG (Brazil); Alonso, Thessa C.; Silva, Teogenes A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2010-07-01

    For the optimization of the patient dose in computed tomography (CT), the Brazilian legislation only established the diagnostic reference levels (DRL's) in terms of Multiple Scan Average Dose (MSAD) in a typical adult as a parameter of quality control of CT scanners. Conformity to the DRL's can be verified by measuring the dose distribution in CT scans and MSAD determination. An analysis of the quality of CT scans of the metropolitan region of Belo Horizonte is necessary by conducting pertinent tests to the study that are presented in the ANVISA (National Agency of Sanitary Vigilance) Guide. The purpose of this study is to investigate, in a chest scan, the variation of dose in CT. To measure the dose profile are used lithium fluoride thermoluminescent dosimeters (TLD-100 Rod) distributed in cylinders positioned in peripheral and central regions of a phantom of polymethylmethacrylate (PMMA). The data obtained allow us to observe the variation of the dose profile inside the phantom. The peripheral region shows higher dose values than the central region. The longitudinal variation can be observed and the maximum dose was recorded at the edges of the phantom (41,58{+-}5,10) mGy at the midpoint of the longitudinal axis. The results will contribute to disseminate the proper procedure and optimize the dosimetry and the tests of quality control in CT, as well as make a critical analysis of the DRL's. (author)

  13. Introduction of guidance dose levels inpaediatrics CT

    International Nuclear Information System (INIS)

    Verdun, F.R.; Valley, J.F.; Bernasconi, M.; Schnyder, P.; Gudinchet, F.

    2001-01-01

    The purpose of this work is to present a methodology in order to define reference levels for chest or abdominal CT examinations performed on children. For children aged from 0 to 6 the CTDI w measured in the head test object (i.e. diameter 16 cm) should be used as a dose indicator. For children older than 12 years old the CTDI w measured in the body test object (i.e. 32 cm) should be used as a dose indicator. For children aged between 6 to 12 we propose to use an intermediate CTDI w in order to avoid an over or underestimation of the dose delivered in the slices. Finally a set of dose length products (DLP) measured in our centre for standard abdominal acquisitions will be given. (author)

  14. Study on fine quartz pre-dose techniques

    International Nuclear Information System (INIS)

    Leung, P.L.; Stokes, M.J.; Wang Weida; Xia Junding

    1996-01-01

    When using the pre-dose technique in ceramic dating, it is essential to add a calibration dose and to eliminate the background dose. For doing this measurement the sample requires multiple activation following multiple administration of a test dose to induce simulated 'ancient' thermoluminescence (TL). However, the procedures introduce many factors that are difficultly corrected. The authors compare existing two kinds of measurement procedures and proposes a new procedure involving single activation following a single test dose administration. An experiment using the single activation procedure is carried out with natural fine quartz where the results obtained exhibit only 0.07 relative error. It appears that this new procedure increases the precision of the ancient TL measurement by about 0.04 and 0.11 over those of existing two kinds of procedures. In addition this method can give realistic values in TL dating for relatively 'young' samples aged tens to hundreds of years where the standard high temperature TL method is relatively insensitive

  15. Polonium-210 activity concentration, transfer and dose to certain invertebrates found in the vicinity of the Kudankulam Nuclear Power Project, Tamil Nadu, India

    International Nuclear Information System (INIS)

    Benjamin, J.; Wesley, S.G.; Rajan, M.P.

    2013-01-01

    Invertebrates are significant reference organisms, and some of them tend to accumulate certain radionuclides in increased levels. It is imperative that the levels of radionuclides are measured in certain organism in the vicinity of any major nuclear power project before its commissioning; hence, this study was carried out in the surroundings of the Kudankulam Nuclear Power Project site. The natural radionuclide polonium-210 having affinity to the organic matter in the soil and to the protein content of the animals, is very significant as it delivers a high internal dose to the organisms. The activity concentration of this radionuclide, its transfer and dose were assessed in two terrestrial (earthworm, Pheretima posthuma and land snail, Trachea vittata) and two aquatic (apple snail, Pila globosa and bivalve mollusc, Lamellidens marginalis) invertebrates. The activity concentration of 210 Po was found to be the highest in the earthworm and the lowest in the land snail. The per-animal dose due to 210 Po was the highest for the apple snail and the lowest for the earthworm. The results indicate that 210 Po does not constitute a significant radiological threat to the organisms. (author)

  16. Dose to population as a metric in the design of optimised exposure control in digital mammography

    International Nuclear Information System (INIS)

    Klausz, R.; Shramchenko, N.

    2005-01-01

    This paper describes a methods for automatic optimisation of parameter (AOP) in digital mammography systems. Using a model of the image chain, contrast to noise ratio (CNR) and average glandular dose (AGD) are computed for possible X-ray parameters and breast types. The optimisation process consists of the determination of the operating points providing the lowest possible AGD for each CNR level and breast type. The proposed metric for the dose used in the design of an AOP mode is the resulting dose to the population, computed by averaging the AGD values over the distribution of breast types in the population. This method has been applied to the automatic exposure control of new digital mammography equipment. Breast thickness and composition are estimated from a low dose pre-exposure and used to index tables containing sets of optimised operating points. The resulting average dose to the population ranges from a level comparable to state-of-the-art screen/film mammography to a reduction by a factor of two. Using this method, both CNR and dose are kept under control for all breast types, taking into consideration both individual and collective risk. (authors)

  17. Sleep Duration Associated with the Lowest Risk of Depression/Anxiety in Adolescents.

    Science.gov (United States)

    Ojio, Yasutaka; Nishida, Atsushi; Shimodera, Shinji; Togo, Fumiharu; Sasaki, Tsukasa

    2016-08-01

    To investigate sleep duration associated with the least depression/anxiety in adolescence. Grades 7-12 Japanese students (n = 18,250, aged 12-18 y) from public junior high/high schools were studied in a cross-sectional design. Due to missing/implausible data, 15,637 out of the 18,250 students were statistically analyzed. Relationship between sleep duration on school nights and depression/anxiety, measured using self-report questionnaires, including the General Health Questionnaire-12 (GHQ-12), were studied by sex and grade, controlling for bedtime regularity. When sleep duration was classified by 1-h intervals, rate of adolescents with a GHQ-12 score ≥ 4 was the lowest in males and females who slept 8.5-9.5 h and 7.5-8.5 h, respectively, (designated "references") in both grades 7-9 and 10-12. The rate was significantly higher than the references in both males and females who slept Sleep duration for the minimum GHQ-12 score was estimated to be 8.8 and 8.5 h in males, and 8.0 and 7.5 h in females, in grades 7-9 and 10-12, respectively, using the General Additive Model. Sleep duration of ≥ 8.5 h on school nights may be associated with the lowest risk of depression/anxiety on average in male adolescents. Although the duration was estimated to be shorter in females (≥ 7.5 h) than males, this should be interpreted carefully. Most adolescents may currently be sleeping less than the optimal duration. A commentary on this article appears in this issue on page 1491. © 2016 Associated Professional Sleep Societies, LLC.

  18. THE LOWEST-MASS MEMBER OF THE β PICTORIS MOVING GROUP

    International Nuclear Information System (INIS)

    Rice, Emily L.; Faherty, Jacqueline K.; Cruz, Kelle L.

    2010-01-01

    We present spectral and kinematic evidence that 2MASS J06085283-2753583 (M8.5γ) is a member of the β Pictoris Moving Group (BPMG, age ∼12 Myr), making it the latest-type known member of this young, nearby association. We confirm low-gravity spectral morphology at both medium and high resolutions in the near-infrared. We present new radial velocity and proper motion measurements, and use these to calculate galactic location and space motion consistent with other high-probability members of the BPMG. The predicted mass range consistent with the object's effective temperature, surface gravity, spectral type, and age is 15-35 M Jup , placing 2MASS 0608-27 well within the brown dwarf mass regime. 2MASS J06085283-2753583 is thus confidently added to the short list of very low mass, intermediate age benchmark objects that inform ongoing searches for the lowest-mass members of nearby young associations.

  19. Time-resolved resonance raman spectrum of all-trans-diphenylbutadiene in the lowest excited singlet state

    DEFF Research Database (Denmark)

    Wilbrandt, Robert Walter; Jensen, Niels-Henrik; Langkilde, F.W.

    1984-01-01

    The resonance Raman spectrwn of all-trans-diphenylbutadiene in its lowest excited S1 state excited in resonance with the S1 → Sn absorption band at 650 nm in non-polar solvents is reported. Three vibrational bands at 1572, 1481 and 1165 cm−1 are observed. A possible assignment of the the 1481 cm−...

  20. Annual individual hygienic assessment of natural exposure doses of the Altai territory model areas population

    Directory of Open Access Journals (Sweden)

    N. Yu. Potseluev

    2016-01-01

    Full Text Available The goal is to determine ionizing radiation natural sources exposure regularities of Altai Territory model areas population. The materials and methods. 11376 radon measurements, 1247 gamma radiation meas-urements in an open area and in residential and office buildings were performed, selection of 189 drinking water tests was carried out. Results. Complex radiation and hygienic examination of the region with the most large municipalities number with model areas allocation was conducted. The assessment of the Altai Territory population’s individual annual radiation doses from natural radionuclides has revealed a number of the regularities depending on the terrain’s ecological and geographical type. Following the research results, ranging the region territories taking into account of annual effective doses of the population from natural sources for 2009-2015 was carried out. The annual individual effective dose of the Altai Territory upland areas population presented by the highest values and ranges from 7.36 mSv / year to 8.19 mSv / year. Foothill regions of Altai and in Salair ridge are characterized by increased population exposure from natural sources. Here the dose ranges from 5.09 mSv / year to 6.22 mSv / year. Steppe and forest-steppe territories are characterized by the lowest level of the natural radiation which is ranging from 3.23 mSv / year to 4.11 mSv / year, that doesn’t exceed the all-Russian levels. Most of the hygienic radon equivalent equilibrium volume activity standards exceedances were registered in mountain and foothill areas buildings. A number of radon anomalies is revealed also in steppe areas. Med exceedances ranged from 203 ± 17.8 Bq / m3 to 480 ± 37.9 Bq / m3. Given the fact that most of these buildings belong to the administrative or educational institutions with an eight-hour working day, the dose of radiation for people there can be up to 10 mSv / year. Conclusion. Spreading of individual annual effective

  1. Effects of aspirin on immobile behavior and endocrine and immune changes in the forced swimming test: comparison to fluoxetine and imipramine.

    Science.gov (United States)

    Guan, Xi-ting; Shao, Feng; Xie, Xi; Chen, Lin; Wang, Weiwen

    2014-09-01

    Aspirin (ASP) is the most commonly used non-steroidal anti-inflammatory drug in the world. Recent clinical and preclinical evidence suggests that ASP may also exert psychoactive effects. It remains unclear whether ASP has antidepressant-like activity, and any molecular mechanisms underlying such activity have yet to be elucidated. Using the forced swimming test (FST), a well-established animal model of depression widely used to screen potential antidepressants in rodents, we investigated the effects of subacute treatment with ASP (0, 6, 12, 25, and 50mg/kg, i.p.) on immobility in the FST, and on FST-induced changes in endocrine and immune parameters in rats, in comparison to the clinical antidepressants imipramine (IMI) and fluoxetine (FLU). Serum levels of corticosterone, pro-inflammatory cytokine interleukin-6 (IL-6), and tumor necrosis factor-α (TNF-α) were determined by enzyme-linked immunosorbent assay. ASP dose-dependently decreased immobility in the FST, without altering the locomotor activity in the open-field test. The inhibitory effects of higher doses (25 and 50mg/kg) of ASP on immobility were similar to that of FLU and IMI at a dose of 10mg/kg. In addition, the levels of corticosterone, IL-6, and TNF-α in peripheral blood were significantly increased after the FST exposure. IMI, but not FLU and ASP at any dose tested, significantly attenuated corticosterone responses in the FST. Both FLU and IMI treatment reduced the increase of IL-6 and TNF-α levels following the FST exposure. ASP dose-dependently decreased FST-induced increase of cytokine levels, as manifested by significantly stronger effects on IL-6 and TNF-α levels at higher doses (25 and 50mg/kg) than the lowest dose of ASP (6 mg/kg). In all, these results indicate that ASP treatment dose-dependently decreased the immobility time and the release of pro-inflammatory cytokines in the FST, suggesting that the anti-inflammatory effects of ASP might be involved in the antidepressant-like effect

  2. Evaluation of absorbed dose-distribution in the X-ray or gamma-irradiator for blood products

    International Nuclear Information System (INIS)

    Moriyama, Satoshi; Kurihara, Katsuhiko; Yokokawa, Nobuhiko; Satake, Masahiro; Juji, Takeo

    2001-01-01

    Irradiation of blood products abrogates the proliferation of lymphocytes present in cellular component, which is currently the only accepted methodology to prevent transfusion-associated graft versus host disease (TA-GVHD). A range of irradiation dose levels between 15 Gy and 50 Gy is being used, but the majority of facilities are employing 15 Gy. It should, however, be recognized that the delivered dose in the instrument canister might differ from the actual dose absorbed by the blood bag. This study have evaluated the actual dose distribution under practical conditions where a container was loaded with blood products or water bags, or filled with distilled water. This approach provides data that the maximum attenuation occurred when the container was completely filled with a blood-compatible material. Thus, an error of approximately 20 percent should be considered in the dose measured in the in-air condition. A dose calibration in an in-air condition may lead to substantial underexposure of the blood products. A dose distribution study using adequately prearranged exposure period verified that the absorbed dose of 15 Gy was attained at any point in the container for both linear accelerator and gamma-irradiator. The maximal difference in the absorbed dose between measured points was 1.5- and 1.6-fold for linear accelerator and gamma-irradiator, respectively. In conclusion, using blood-compatible materials, a careful dose calibration study should be employed in which the absorbed dose of 15 Gy is obtained at the point where the lowest dose could be expected. (author)

  3. Radiation exposure to examiners and patients during therapeutic ERCP: Dose optimisation and risk estimation

    International Nuclear Information System (INIS)

    Sulieman, A.; Kappas, K.; Theodorou, K.; Paroutoglou, G.; Kapatenakis, A.; Kapsoritakis, A.; Potamianos, S.; Vlychou, M.; Fezoulidis, I.

    2008-01-01

    Aim: This study intended to optimise the radiation dose during therapeutic ERCP, and to estimate the risk for examiners and patients, to compare the doses based on available data obtained by other researchers and reference levels recommended by international organizations, and to evaluate the technique applied in order to reduce patient and examiners doses. Materials and Methods: 153 patients were studied in two Gastroenterology Departments, (group A, 111; group B, 42). Thermoluminescent dosimeters (TLD) were used to measure the staff and patients entrance surface dose (ESD) at different body sites. Results: The mean ESD, exit and thyroid surface dose per procedure was estimated to be 68.75 mGy, 3.45 mGy and 0.67 mGy, respectively. The mean patient effective dose was 3.44 mSv, and the cancer risk per procedure was estimated to be 190 x10 -6 . The effective dose for the first, second and third examiner was 0.4 μSv, 0.2 μSv and 5.0 μSv, respectively. Conclusion: The patient dose can be optimized by the presence of two experienced examiners and reduction of radiographic images. The examiners should use a wrap around lead apron since the highest dose originating from the X-ray tube, is incident on their side and back. The current formulae, which exist, underestimate the effective dose to the examiners, when they are applied for ERCP procedures. For both patients and examiners, our results were up to 60% lower compared to the lowest values found in previous studies. (authors)

  4. Effect of ultra-low dose whole-body-irradiation on severe patients with myasthenia gravis

    International Nuclear Information System (INIS)

    Arimori, Shigeru; Koriyama, Kenji

    1982-01-01

    An ultra-low dose whole body irradiation therapy was given to 5 patients with intractable bulbar syndrome, in a dose of 10 rad/fraction, 2 times a week for 5 weeks, with a total of 100 rad; and effects of this therapy on their clinical symptoms and immunological ability were discussed. In 3 of them, bulbar syndrome was improved, and the other one, the first irradiation was effective. The peripheral leukocyte count and lymphocyte count became lowest immediately after completion of the irradiation, and returned to the normal level within 1 to 2 months. The function of T-cells, especially suppressive T-cells, was recovered; and decrease in B-cells, resulted in a decrease in the AChR antibody titer. (Ueda, J.)

  5. Effect of ultra-low dose whole-body-irradiation on patients with severe myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Arimori, Shigeru; Koriyama, Kenji (Tokai Univ., Isehara, Kanagawa (Japan). School of Medicine)

    1982-12-01

    An ultra-low dose whole body irradiation therapy was given to 5 patients with intractable bulbar syndrome, in a dose of 10 rad/fraction, 2 times a week for 5 weeks, with a total of 100 rad; and effects of this therapy on their clinical symptoms and immunological ability were discussed. In 3 of them, bulbar syndrome was improved, and the other one, the first irradiation was effective. The peripheral leukocyte count and lymphocyte count became lowest immediately after completion of the irradiation, and returned to the normal level within 1 to 2 months. The function of T-cells, especially suppressive T-cells, was recovered; and decrease in B-cells, resulted in a decrease in the AChR antibody titer.

  6. Dose-response effects of systemic anandamide administration in mice sequentially submitted to the open field and elevated plus-maze tests.

    Science.gov (United States)

    Ribeiro, A; Ferraz-de-Paula, V; Pinheiro, M L; Palermo-Neto, J

    2009-06-01

    The endocannabinoid system is involved in the control of many physiological functions, including the control of emotional states. In rodents, previous exposure to an open field increases the anxiety-like behavior in the elevated plus-maze. Anxiolytic-like effects of pharmacological compounds that increase endocannabinoid levels have been well documented. However, these effects are more evident in animals with high anxiety levels. Several studies have described characteristic inverted U-shaped dose-response effects of drugs that modulate the endocannabinoid levels. However, there are no studies showing the effects of different doses of exogenous anandamide, an endocannabinoid, in animal models of anxiety. Thus, in the present study, we determined the dose-response effects of exogenous anandamide at doses of 0.01, 0.1, and 1.0 mg/kg in C57BL/6 mice (N = 10/group) sequentially submitted to the open field and elevated plus-maze. Anandamide was diluted in 0.9% saline, ethyl alcohol, Emulphor (18:1:1) and administered ip (0.1 mL/10 g body weight); control animals received the same volume of anandamide vehicle. Anandamide at the dose of 0.1 mg/kg (but not of 0.01 or 1 mg/kg) increased (P open field, as well as the exploration of the open arms of the elevated plus-maze. Thus, exogenous anandamide, like pharmacological compounds that increase endocannabinoid levels, promoted a characteristic inverted U-shaped dose-response effect in animal models of anxiety. Furthermore, anandamide (0.1 mg/kg) induced an anxiolytic-like effect in the elevated plus-maze (P open field test.

  7. SU-F-T-628: An Evaluation of Grid Size in Eclipse AcurosXB Dose Calculation Algorithm for SBRT Lung

    Energy Technology Data Exchange (ETDEWEB)

    Pokharel, S [21st Century Oncology, Naples, FL (United States); Rana, S [McLaren Proton Therapy Center, Karmanos Cancer Institute at McLaren-Flint, Flint, MI (United States)

    2016-06-15

    Purpose: purpose of this study is to evaluate the effect of grid size in Eclipse AcurosXB dose calculation algorithm for SBRT lung. Methods: Five cases of SBRT lung previously treated have been chosen for present study. Four of the plans were 5 fields conventional IMRT and one was Rapid Arc plan. All five cases have been calculated with five grid sizes (1, 1.5, 2, 2.5 and 3mm) available for AXB algorithm with same plan normalization. Dosimetric indices relevant to SBRT along with MUs and time have been recorded for different grid sizes. The maximum difference was calculated as a percentage of mean of all five values. All the plans were IMRT QAed with portal dosimetry. Results: The maximum difference of MUs was within 2%. The time increased was as high as 7 times from highest 3mm to lowest 1mm grid size. The largest difference of PTV minimum, maximum and mean dose were 7.7%, 1.5% and 1.6% respectively. The highest D2-Max difference was 6.1%. The highest difference in ipsilateral lung mean, V5Gy, V10Gy and V20Gy were 2.6%, 2.4%, 1.9% and 3.8% respectively. The maximum difference of heart, cord and esophagus dose were 6.5%, 7.8% and 4.02% respectively. The IMRT Gamma passing rate at 2%/2mm remains within 1.5% with at least 98% points passing with all grid sizes. Conclusion: This work indicates the lowest grid size of 1mm available in AXB is not necessarily required for accurate dose calculation. The IMRT passing rate was insignificant or not observed with the reduction of grid size less than 2mm. Although the maximum percentage difference of some of the dosimetric indices appear large, most of them are clinically insignificant in absolute dose values. So we conclude that 2mm grid size calculation is best compromise in light of dose calculation accuracy and time it takes to calculate dose.

  8. Development of a dosimeter for high doses assessment based on Alanine/EPR

    International Nuclear Information System (INIS)

    Galante, O.L.; Rodrigues, O. Jr.; Campos, L.L.

    2000-01-01

    The increasing use of radiation sources of high activity for industrial and medical applications becomes important the research and the development of detectors and dosimetric methods for quality control of the applied doses. This work presents the current stage of the research at IPEN/CNEN-SP that has as objective the development of a standard dosimetric system for high doses assessment based on the alanine as radiation detector and electron paramagnetic resonance (EPR) as measurement technique. The developed system consists of the cylindrical container built in polyethylene of high density and the detector element based on DL-alanine commercially available. For the detector preparation different binding materials such as paraffin and acetate polyvinyl solution (pva) and also the use of a polyethylene tube of low density with 3.2 mm of external diameter, 2 mm of internal diameter and 30 mm of length were tested to provide the easier preparation method and the most sensitive detector. For the alanine + paraffin detector it was used 80% of alanine and 20% of paraffin, for the alanine + pva detector it was used 70% of alanine and 30% of pva solution, and pure alanine was encapsulated, compacted and sealed in the case of the polyethylene tube. The obtained results with respect to handling, packing and construction easiness showed that the polyethylene tube presents all characteristics to obtain of a good detector element. The validation of the dosimetric system was carried out with gamma radiation of the cobalt-60 with doses in the range between 0.2 Gy to 200 kGy. Type tests such as fading, lowest detection limit, reproducibility and energy dependence of the sign EPR were performed. All measurements were carried out at room temperature using a spectrometer of electron paramagnetic resonance (EPR) Bruker model MXE. Taking into account the results obtained: linearity of the EPR signal between 10 Gy and 50 kGy, reproducibility better than 3%, low fading associated with

  9. Impurity binding energy of lowest-excited state in (In,Ga)N–GaN spherical QD under electric field effect

    International Nuclear Information System (INIS)

    Ghazi, Haddou El; Jorio, Anouar; Zorkani, Izeddine

    2013-01-01

    External electric field effect on the lowest-excited state in wurtzite (In,Ga)N–GaN spherical quantum dot is considered. By means of a traditional Ritz variational method within the effective-mass approximation and finite potential barrier, the lowest-excited state energy with and without the presence of the impurity is investigated. The normalized binding energy under electric field effect is also performed. Our numerical results are compared with the previous theoretical findings and show a good agreement with those concerning especially the ground-state for different semiconductors materials and different QDs-shapes

  10. Impurity binding energy of lowest-excited state in (In,Ga)N–GaN spherical QD under electric field effect

    Energy Technology Data Exchange (ETDEWEB)

    Ghazi, Haddou El, E-mail: hadghazi@gmail.com [LPS, Faculty of Sciences, Dhar EL Mehrez, B.P 1796 Atlas, Fez (Morocco); Special Mathematics, CPGE Kénitra (Morocco); Jorio, Anouar; Zorkani, Izeddine [LPS, Faculty of Sciences, Dhar EL Mehrez, B.P 1796 Atlas, Fez (Morocco)

    2013-10-01

    External electric field effect on the lowest-excited state in wurtzite (In,Ga)N–GaN spherical quantum dot is considered. By means of a traditional Ritz variational method within the effective-mass approximation and finite potential barrier, the lowest-excited state energy with and without the presence of the impurity is investigated. The normalized binding energy under electric field effect is also performed. Our numerical results are compared with the previous theoretical findings and show a good agreement with those concerning especially the ground-state for different semiconductors materials and different QDs-shapes.

  11. The response of mouse skin to multiple small doses of radiation

    International Nuclear Information System (INIS)

    Denekamp, J.; Harris, S.R.

    1975-01-01

    The response of mouse skin has been tested by irradiating the foot of albino mice and scoring erythema and desquamation during the following month. Multiple small doses of 150, 250 and 350 rad have been given 'daily', and the test dose necessary to achieve a given reaction has been determined one day after the last small fraction. This test dose has been compared with the single dose necessary to produce the same reaction level in previously untreated mice, in order to determine the ratio of the slopes of the dose-response curve at low and high doses: Slope ratio = (single dose - test dose)/total fractionated priming dose. In three separate experiments the slope ratio decreased as the dose per fraction was reduced from 350 to 150 rad. This conflicts with the data of Dutreix et al, who found a constant slope ratio over this dose range. The present data are compared with those obtained by Denekamp using 4, 9 and 14 fractions of 300 rad and by Douglas et al, using the same experimental technique, over the dose range 45 to 200 rad/fraction. In addition, the results from multifraction experiments in which equal dose increments were administered until the requisite skin reaction was achieved are also analysed in terms of their slope ratio (Fowler et al. Douglas et al). When all these results are plotted it is impossible to be sure whether the slope ratio is decreasing over the range 300 to 45 rad per fraction, although it seems likely. Most of the values at low doses lie in the range 0.15 to 0.25, indicating that at low doses the radiation is only 15 to 25% as effective per rad in causing cell death as at higher doses. (author)

  12. Protection of testes during radiation treatment by irregular and focused fields of 25 MV x-rays: in vivo evaluation of the absorbed dose.

    Science.gov (United States)

    Marcie, S; Costa, A; Lagrange, J L

    1995-01-01

    During therapeutic irradiation of subdiaphragmatic nodal areas, the gonads are exposed to radiation from the primary beam and scatter. Since young patients have a high probability of cure, limiting exposure to the gonads should be pursued. Primary shielding may be supplemented by additional shields in order to reduce this exposure. Testes dose measurements were performed with thermoluminescent dosimetry (TLD) in 37 patients treated with 25 MV x-rays on subdiaphragmatic nodal areas. Each patient was measured 5 times while under treatment. In 27 cases, an additional shield was placed to protect the testes. For 9 cases, comparative measurements were performed on a phantom with and without additional shielding. The median dose received by gonads was respectively 3% with additional shielding (27 cases) and 5.8% without additional shielding (10 cases, p = 0.001 Mann Whitney test). In the 6 patients for whom the measurements were compared, the differences were also statistically significant (p = 0.028 paired Wilcoxon test). This study confirmed the benefit of additional gonadal shielding during subdiaphragmatic radiation treatment with 25 MV x-rays.

  13. Psilocybin occasioned mystical-type experiences: immediate and persisting dose-related effects.

    Science.gov (United States)

    Griffiths, Roland R; Johnson, Matthew W; Richards, William A; Richards, Brian D; McCann, Una; Jesse, Robert

    2011-12-01

    This dose-effect study extends previous observations showing that psilocybin can occasion mystical-type experiences having persisting positive effects on attitudes, mood, and behavior. This double-blind study evaluated psilocybin (0, 5, 10, 20, 30 mg/70 kg, p.o.) administered under supportive conditions. Participants were 18 adults (17 hallucinogen-naïve). Five 8-h sessions were conducted individually for each participant at 1-month intervals. Participants were randomized to receive the four active doses in either ascending or descending order (nine participants each). Placebo was scheduled quasi-randomly. During sessions, volunteers used eyeshades and were instructed to direct their attention inward. Volunteers completed questionnaires assessing effects immediately after and 1 month after each session, and at 14 months follow-up. Psilocybin produced acute perceptual and subjective effects including, at 20 and/or 30 mg/70 kg, extreme anxiety/fear (39% of volunteers) and/or mystical-type experience (72% of volunteers). One month after sessions at the two highest doses, volunteers rated the psilocybin experience as having substantial personal and spiritual significance, and attributed to the experience sustained positive changes in attitudes, mood, and behavior, with the ascending dose sequence showing greater positive effects. At 14 months, ratings were undiminished and were consistent with changes rated by community observers. Both the acute and persisting effects of psilocybin were generally a monotonically increasing function of dose, with the lowest dose showing significant effects. Under supportive conditions, 20 and 30 mg/70 kg psilocybin occasioned mystical-type experiences having persisting positive effects on attitudes, mood, and behavior. Implications for therapeutic trials are discussed.

  14. An international pooled analysis for obtaining a benchmark dose for environmental lead exposure in children

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Esben; Bellinger, David; Lanphear, Bruce

    2013-01-01

    Lead is a recognized neurotoxicant, but estimating effects at the lowest measurable levels is difficult. An international pooled analysis of data from seven cohort studies reported an inverse and supra-linear relationship between blood lead concentrations and IQ scores in children. The lack...... of a clear threshold presents a challenge to the identification of an acceptable level of exposure. The benchmark dose (BMD) is defined as the dose that leads to a specific known loss. As an alternative to elusive thresholds, the BMD is being used increasingly by regulatory authorities. Using the pooled data...... yielding lower confidence limits (BMDLs) of about 0.1-1.0 μ g/dL for the dose leading to a loss of one IQ point. We conclude that current allowable blood lead concentrations need to be lowered and further prevention efforts are needed to protect children from lead toxicity....

  15. TU-H-CAMPUS-JeP3-02: Automated Dose Accumulation and Dose Accuracy Assessment for Online Or Offline Adaptive Replanning

    International Nuclear Information System (INIS)

    Chen, G; Ahunbay, E; Li, X

    2016-01-01

    Purpose: With introduction of high-quality treatment imaging during radiation therapy (RT) delivery, e.g., MR-Linac, adaptive replanning of either online or offline becomes appealing. Dose accumulation of delivered fractions, a prerequisite for the adaptive replanning, can be cumbersome and inaccurate. The purpose of this work is to develop an automated process to accumulate daily doses and to assess the dose accumulation accuracy voxel-by-voxel for adaptive replanning. Methods: The process includes the following main steps: 1) reconstructing daily dose for each delivered fraction with a treatment planning system (Monaco, Elekta) based on the daily images using machine delivery log file and considering patient repositioning if applicable, 2) overlaying the daily dose to the planning image based on deformable image registering (DIR) (ADMIRE, Elekta), 3) assessing voxel dose deformation accuracy based on deformation field using predetermined criteria, and 4) outputting accumulated dose and dose-accuracy volume histograms and parameters. Daily CTs acquired using a CT-on-rails during routine CT-guided RT for sample patients with head and neck and prostate cancers were used to test the process. Results: Daily and accumulated doses (dose-volume histograms, etc) along with their accuracies (dose-accuracy volume histogram) can be robustly generated using the proposed process. The test data for a head and neck cancer case shows that the gross tumor volume decreased by 20% towards the end of treatment course, and the parotid gland mean dose increased by 10%. Such information would trigger adaptive replanning for the subsequent fractions. The voxel-based accuracy in the accumulated dose showed that errors in accumulated dose near rigid structures were small. Conclusion: A procedure as well as necessary tools to automatically accumulate daily dose and assess dose accumulation accuracy is developed and is useful for adaptive replanning. Partially supported by Elekta, Inc.

  16. Dose-Effect Relationships for Individual Pelvic Floor Muscles and Anorectal Complaints After Prostate Radiotherapy

    International Nuclear Information System (INIS)

    Smeenk, Robert Jan; Hoffmann, Aswin L.; Hopman, Wim P.M.; Lin, Emile N.J. Th. van; Kaanders, Johannes H.A.M.

    2012-01-01

    Purpose: To delineate the individual pelvic floor muscles considered to be involved in anorectal toxicity and to investigate dose-effect relationships for fecal incontinence-related complaints after prostate radiotherapy (RT). Methods and Materials: In 48 patients treated for localized prostate cancer, the internal anal sphincter (IAS) muscle, the external anal sphincter (EAS) muscle, the puborectalis muscle (PRM), and the levator ani muscles (LAM) in addition to the anal wall (Awall) and rectal wall (Rwall) were retrospectively delineated on planning computed tomography scans. Dose parameters were obtained and compared between patients with and without fecal urgency, incontinence, and frequency. Dose-effect curves were constructed. Finally, the effect of an endorectal balloon, which was applied in 28 patients, was investigated. Results: The total volume of the pelvic floor muscles together was about three times that of the Awall. The PRM was exposed to the highest RT dose, whereas the EAS received the lowest dose. Several anal and rectal dose parameters, as well as doses to all separate pelvic floor muscles, were associated with urgency, while incontinence was associated mainly with doses to the EAS and PRM. Based on the dose-effect curves, the following constraints regarding mean doses could be deduced to reduce the risk of urgency: ≤30 Gy to the IAS; ≤10 Gy to the EAS; ≤50 Gy to the PRM; and ≤40 Gy to the LAM. No dose-effect relationships for frequency were observed. Patients treated with an endorectal balloon reported significantly less urgency and incontinence, while their treatment plans showed significantly lower doses to the Awall, Rwall, and all pelvic floor muscles. Conclusions: Incontinence-related complaints show specific dose-effect relationships to individual pelvic floor muscles. Dose constraints for each muscle can be identified for RT planning. When only the Awall is delineated, substantial components of the continence apparatus are

  17. Dose-effect relationships for individual pelvic floor muscles and anorectal complaints after prostate radiotherapy.

    Science.gov (United States)

    Smeenk, Robert Jan; Hoffmann, Aswin L; Hopman, Wim P M; van Lin, Emile N J Th; Kaanders, Johannes H A M

    2012-06-01

    To delineate the individual pelvic floor muscles considered to be involved in anorectal toxicity and to investigate dose-effect relationships for fecal incontinence-related complaints after prostate radiotherapy (RT). In 48 patients treated for localized prostate cancer, the internal anal sphincter (IAS) muscle, the external anal sphincter (EAS) muscle, the puborectalis muscle (PRM), and the levator ani muscles (LAM) in addition to the anal wall (Awall) and rectal wall (Rwall) were retrospectively delineated on planning computed tomography scans. Dose parameters were obtained and compared between patients with and without fecal urgency, incontinence, and frequency. Dose-effect curves were constructed. Finally, the effect of an endorectal balloon, which was applied in 28 patients, was investigated. The total volume of the pelvic floor muscles together was about three times that of the Awall. The PRM was exposed to the highest RT dose, whereas the EAS received the lowest dose. Several anal and rectal dose parameters, as well as doses to all separate pelvic floor muscles, were associated with urgency, while incontinence was associated mainly with doses to the EAS and PRM. Based on the dose-effect curves, the following constraints regarding mean doses could be deduced to reduce the risk of urgency: ≤ 30 Gy to the IAS; ≤ 10 Gy to the EAS; ≤ 50 Gy to the PRM; and ≤ 40 Gy to the LAM. No dose-effect relationships for frequency were observed. Patients treated with an endorectal balloon reported significantly less urgency and incontinence, while their treatment plans showed significantly lower doses to the Awall, Rwall, and all pelvic floor muscles. Incontinence-related complaints show specific dose-effect relationships to individual pelvic floor muscles. Dose constraints for each muscle can be identified for RT planning. When only the Awall is delineated, substantial components of the continence apparatus are excluded. Copyright © 2012 Elsevier Inc. All rights

  18. Study of the contribution of X-ray and gamma photons to the measured exposure dose

    International Nuclear Information System (INIS)

    Andriampanarivo, H.L.H.

    2000-01-01

    The aim of this work was to study the contribution of X-rays and gamma radiation to the measured dose in the city of Antananarivo. The annual indoor absorbed dose was studied as well. Measurements were carried out in twelve sites, namely public schools and churches. The mean dose rate lies between (0.34±0.03)μSv/h and (0.38±0.04)μSv/h for most of the sites. Two of them showed values between (0.40±0.04)μSv/h and (0.30±0.03)μSv/h. Mean indoor dose rate is of (0.36±0.04)μSv/h and the annual absorbed dose is (3.16±0.32)mSv/person. Indoor measurements showed mean integral values ranging from (277.22±0,22)cps to (733.66±0,37)cps. The lowest mean count rate is (277.22±0,22)cps, measured in the AMARO site, whereas the highest are (733,66±0,37)cps, (697,81±0,36)cps and (689,32±0,36)cps measured in ALO0 , AKELY, and MASINA respectively. [fr

  19. The effect of small dose bupivacaine-fentanyl in spinal anesthesia on hemodynamic nausea and vomiting in cesarean section

    International Nuclear Information System (INIS)

    Seyedhejazi, M.; Madarek, E.

    2007-01-01

    To compare the hemodynamic, nausea and vomiting with small dose bupivacaine-fentanyl spinal anesthetic versus a conventional dose of spinal bupivacaine in parturients undergoing cesarean section. Forty patients aged 17-35 years old which underwent cesarean section were randomized into two groups. Group-A received spinal anesthesia with 8 mg of bupivacaine and 10 microg fentanyl, group B received 12 mg bupivacaine. The mean dose of ephedrine needed was 4mg in group A and 11.75 mg in group B (P=0.006). The mean ratio of lowest systolic pressure to baseline systolic pressure was 0.75 for group A and 0.65 for group B (P=0.04). Nausea and vomiting was observed in 10% of group A versus 20% in group B. Small dose of bupivacaine and fentanyl provides good spinal anesthesia for cesarean section with less hypotension, nausea and vomiting. (author)

  20. PA positioning significantly reduces testicular dose during sacroiliac joint radiography

    International Nuclear Information System (INIS)

    Mekis, Nejc; Mc Entee, Mark F.; Stegnar, Peter

    2010-01-01

    Radiation dose to the testes in the antero-posterior (AP) and postero-anterior (PA) projection of the sacroiliac joint (SIJ) was measured with and without a scrotal shield. Entrance surface dose, the dose received by the testicles and the dose area product (DAP) was used. DAP measurements revealed the dose received by the phantom in the PA position is 12.6% lower than the AP (p ≤ 0.009) with no statistically significant reduction in image quality (p ≤ 0.483). The dose received by the testes in the PA projection in SIJ imaging is 93.1% lower than the AP projection when not using protection (p ≤ 0.020) and 94.9% lower with protection (p ≤ 0.019). The dose received by the testicles was not changed by the use of a scrotal shield in the AP position (p ≤ 0.559); but was lowered by its use in the PA (p ≤ 0.058). Use of the PA projection in SIJ imaging significantly lowers, the dose received by the testes compared to the AP projection without significant loss of image quality.

  1. Lowest excited-state impurity binding energy in InGaN/GaN parabolic QWW: magnetic field effect

    International Nuclear Information System (INIS)

    Haddou El Ghazi; Anouar Jorio; Izeddine Zorkani

    2013-01-01

    In this paper, we have investigated the magnetic field effect on the lowest excited-state binding energy of hydrogenic shallow-donor impurity in wurtzite (In,Ga)N/GaN parabolic transversal-section quantum-well wire (PQWW) using the finite-difference method within the quasi-one-dimensional effective potential model. The calculations are performed within the framework of the effective mass approximation. A cylindrical QWW effective radius is taken into account to describe the lateral confinement strength. The numerical results show that: (i) the probability density is the largest on a circularity whose radius is the effective radius and (ii) the lowest excited-state binding energy is the largest when an impurity is located on this circularity while it starts to decrease as the impurity is away from the circularity. (author)

  2. ANTIMICROBIAL ACTIVITY OF “DUTSEN DAN LIBYA”

    African Journals Online (AJOL)

    DJFLEX

    the test organisms showed the lowest MIC at the dose level of 1.25mg/ml and MBC at the dose level of 2.50mg/ ... KEYWORDS: Antimicrobial, Infectious disease, Pathogenic, Bacteria, Fungi ... poverty and increasing incidence of multiple drug.

  3. Patient radiation doses in therapeutic endoscopic retrograde cholangiopancreatography in Patras and the key role of the operator

    International Nuclear Information System (INIS)

    Hadjiconstanti, Anastasia C.; Messaris, Gerasimos A. T.; Panayiotakis, George S.; Thomopoulos, Konstantinos C.

    2017-01-01

    The patient radiation doses, in conjunction with the operator experience, in therapeutic endoscopic retrograde cholangiopancreatography (ERCP) procedures, performed in our hospital, were obtained. Ninety-six patients participated in the study and were divided into 3 groups, based on the operator experience. The dosimetric indices, fluoroscopy time (FT), cumulative dose (K a,r ) and air kerma-area product (P KA ), were collected. For the total and weight banding group the third quartile values of the distribution of FT, K a,r and P KA were 2.90 and 2.92 min, 6.89 and 6.93 mGy and 1.84 and 1.85 Gycm 2 , respectively, and were comparative or significantly lower than the corresponding values previously reported. Taking as a criterion the operator, the differences in the patient radiation doses were statistically significant, with the highest dose recorded for the operator of the lowest experience degree. The values obtained could contribute in establishing local and national diagnostic reference levels and in optimising ERCP procedure. (authors)

  4. Evaluation of repeated dose micronucleus assays of the liver using N-nitrosopyrrolidine: a report of the collaborative study by CSGMT/JEMS.MMS.

    Science.gov (United States)

    Ogawa, Izumi; Hagioa, Soichiro; Furukawa, Satoshi; Abe, Masayoshi; Kuroda, Yusuke; Hayashi, Seigo; Wako, Yumi; Kawasako, Kazufumi

    2015-03-01

    The repeated dose liver micronucleus (RDLMN) assay has the potential to detect liver carcinogens, and can be integrated into a general toxicological study. To assess the performance of the assay, N-nitrosopyrrolidine (NPYR), a genotoxic hepatocarcinogen, was tested in 14- or 28-day RDLMN assays. NPYR was orally administered to rats at a daily dose of 25, 50 or 100 mg/kg. One day after the last administration, a portion of the liver was removed and hepatocyte micronucleus (MN) specimens were prepared by the new method recently established by Narumi et al. In addition, a bone marrow MN assay and a histopathological examination of the liver were conducted. The detection of Phospho-Histone H3 was performed by immunohistochemistry to evaluate the proliferation rate of hepatocytes. The results showed significant increase in the number of micronucleated hepatocytes and Phospho-Histone H3-positive cells from the lowest dose in both 14- and 28-day RDLMN assays. On the other hand, the bone marrow MN assay yielded a negative result, which was in accordance with the existing report of the bone marrow MN assay using mice. Upon histopathological examination, inflammatory lesions and hypertrophy were noted, which may explain the increase in the hepatocyte proliferation and the enhancement of MN induction by NPYR. Our findings indicate that the RDLMN assay could be a useful tool for comprehensive risk assessment of carcinogenicity by providing information on both genotoxicity and histopathology when integrated into a general repeat dosing toxicity assay.

  5. An updated dose assesment for resettlement options at Bikini atoll - A US nuclear test site

    International Nuclear Information System (INIS)

    Robison, W.L.; Bogen, K.T.; Conrado, C.L.

    1997-01-01

    There has been a continuing effort since 1977 to refine dose assessments for resettlement options at Bikini Atoll. Here we provide a radiological dose assessment for the main residence island, Bikini, using extensive radio nuclide concentration data derived from analysis of food crops, ground water, cistern water, fish and other marine species, animals, air, and soil collected at Bikini Island as part of our continuing research and monitoring program that began in 1978. The unique composition of coral soil greatly alters the relative contribution of 137 Cs and 90 Sr to the total estimated dose relative to expectations based on North American and European soils. Without counter measures, 137 Cs produces 96% of the estimated dose for returning residents, mostly through uptake from the soil to terrestrial food crops but also from external gamma exposure. The doses are calculated assuming a resettlement date of 1999. The estimated maximum annual effective dose for current island conditions is 4.0 mSv when imported foods, which are now an established part of the diet, are available. The 30-, 50-, and 70-y integral effective doses are 91 mSv, 130 mSv, and 150 mSv, respectively. A detailed uncertainty analysis for these dose estimates is presented in a companion paper in this issue. We have evaluated various countermeasures to reduce 137 Cs in food crops. Treatment with potassium reduces the uptake of 137 Cs into food crops, and therefore the ingestion dose, to about 5 % of pretreatment levels and has essentially no negative environmental consequences. We have calculated the dose for the rehabilitation scenario where the top 40 cm of soil is removed in the housing and village area, and the rest of the island is treated with potassium fertilizer; the maximum annual effective dose is 0.41 mSv and the 30-, 50-, and 70-y integral effective doses are 9.8 mSv, 14 mSv, and 16 mSv, respectively. 44 refs., 3 figs., 11 tabs

  6. SU-F-T-32: Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source

    Energy Technology Data Exchange (ETDEWEB)

    Harpool, K; De La Fuente Herman, T; Ahmad, S; Ali, I [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2016-06-15

    Purpose: To evaluate the performance of a two-dimensional (2D) array-diode- detector for geometric and dosimetric quality assurance (QA) tests of high-dose-rate (HDR) brachytherapy with an Ir-192-source. Methods: A phantom setup was designed that encapsulated a two-dimensional (2D) array-diode-detector (MapCheck2) and a catheter for the HDR brachytherapy Ir-192 source. This setup was used to perform both geometric and dosimetric quality assurance for the HDR-Ir192 source. The geometric tests included: (a) measurement of the position of the source and (b) spacing between different dwell positions. The dosimteric tests include: (a) linearity of output with time, (b) end effect and (c) relative dose verification. The 2D-dose distribution measured with MapCheck2 was used to perform the previous tests. The results of MapCheck2 were compared with the corresponding quality assurance testes performed with Gafchromic-film and well-ionization-chamber. Results: The position of the source and the spacing between different dwell-positions were reproducible within 1 mm accuracy by measuring the position of maximal dose using MapCheck2 in contrast to the film which showed a blurred image of the dwell positions due to limited film sensitivity to irradiation. The linearity of the dose with dwell times measured from MapCheck2 was superior to the linearity measured with ionization chamber due to higher signal-to-noise ratio of the diode readings. MapCheck2 provided more accurate measurement of the end effect with uncertainty < 1.5% in comparison with the ionization chamber uncertainty of 3%. Although MapCheck2 did not provide absolute calibration dosimeter for the activity of the source, it provided accurate tool for relative dose verification in HDR-brachytherapy. Conclusion: The 2D-array-diode-detector provides a practical, compact and accurate tool to perform quality assurance for HDR-brachytherapy with an Ir-192 source. The diodes in MapCheck2 have high radiation sensitivity and

  7. Dose-response study of thimerosal-induced murine systemic autoimmunity

    International Nuclear Information System (INIS)

    Havarinasab, S.; Lambertsson, L.; Qvarnstroem, J.; Hultman, P.

    2004-01-01

    The organic compound ethylmercurithiosalicylate (thimerosal), which is primarily present in the tissues as ethylmercury, has caused illness and several deaths due to erroneous handling when used as a disinfectant or as a preservative in medical preparations. Lately, possible health effects of thimerosal in childhood vaccines have been much discussed. Thimerosal is a well-known sensitizing agent, although usually of no clinical relevance. In rare cases, thimerosal has caused systemic immune reactions including acrodynia. We have studied if thimerosal might induce the systemic autoimmune condition observed in genetically susceptible mice after exposure to inorganic mercury. A.SW mice were exposed to 1.25-40 mg thimerosal/l drinking water for 70 days. Antinucleolar antibodies, targeting the 34-kDa protein fibrillarin, developed in a dose-related pattern and first appeared after 10 days in the two highest dose groups. The lowest observed adverse effect level (LOAEL) for antifibrillarin antibodies was 2.5 mg thimerosal/l, corresponding to an absorbed dose of 147 μg Hg/kg bw and a concentration of 21 and 1.9 μg Hg/g in the kidney and lymph nodes, respectively. The same LOAEL was found for tissue immune-complex deposits. The total serum concentration of IgE, IgG1, and IgG2a showed a significant dose-related increase in thimerosal-treated mice, with a LOAEL of 5 mg thimerosal/l for IgG1 and IgE, and 20 mg thimerosal/l for IgG2a. The polyclonal B-cell activation showed a significant dose-response relationship with a LOAEL of 10 mg thimerosal/l. Therefore, thimerosal induces in genetically susceptible mice a systemic autoimmune syndrome very similar to that seen after treatment with inorganic mercury, although a higher absorbed dose of Hg is needed using thimerosal. The autoimmune syndrome induced by thimerosal is different from the weaker and more restricted autoimmune reaction observed after treatment with an equipotent dose of methylmercury

  8. Testing the Capacity of the National Biological Dose Response Plan (NBDRP) EX40801

    Science.gov (United States)

    2009-11-01

    Blood Collection All donors were volunteers that willingly responded to an advertising call for participation in a research proposal approved by...Scorers from the same laboratory are shown in the same colour . In Figure 2, the dose estimates based on QuickScan are shown. Figure 3 shows the doses

  9. The Leoncino Dwarf: The Lowest Metallicity Star-Forming Galaxy in the Nearby Universe

    Science.gov (United States)

    McQuinn, Kristen

    2017-08-01

    Extremely metal-poor (XMP) galaxies are dwarf irregular galaxies with very low metallicities, traced by their gas-phase oxygen abundance. Galaxy evolution scenarios suggest three pathways to form an XMP: (1) secular evolution at low galaxy masses, (2) slow evolution in voids, or (3) dilution of measured abundances from infall of pristine gas. These scenarios have proven challenging to test because, despite concerted efforts, XMP galaxies in the nearby universe have proven hard to find. A notable exception is the recently discovered dwarf galaxy Leoncino. Leoncino has the lowest gas-phase oxygen abundance ever measured in a galaxy in the local Universe. From optical spectroscopy, the oxygen abundance is 12+log(O/H)=7.02+/-0.03, more than 40% lower than the iconic low-metallicity galaxy I Zw 18 and less than 2% Z_sun. Despite a precision oxygen abundance measurement, the evolutionary context of Leoncino remains uncertain without a secure distance. We propose HST WFC3 high-resolution optical imaging of Leoncino to accurately measure the distance to the galaxy using the tip of the red giant branch (TRGB) method. The distance will determine whether Leoncino is located in a typical field environment or in a void, and whether the galaxy is consistent with the luminosity-metallicity relation at low galaxy masses. The detailed study of Leoncino will provide benchmark results for future XMP discoveries in the nearby Universe, and an exceptionally timely comparison for studies of chemically primitive, high-redshift galaxies that will be observable in the JWST era.

  10. Dose sparing of induction dose of propofol by fentanyl and butorphanol: A comparison based on entropy analysis

    Directory of Open Access Journals (Sweden)

    Jasleen Kaur

    2013-01-01

    Full Text Available Background: The induction dose of propofol is reduced with concomitant use of opioids as a result of a possible synergistic action. Aim and Objectives: The present study compared the effect of fentanyl and two doses of butorphanol pre-treatment on the induction dose of propofol, with specific emphasis on entropy. Methods: Three groups of 40 patients each, of the American Society of Anaesthesiologistsphysical status I and II, were randomized to receive fentanyl 2 μg/kg (Group F, butorphanol 20 μg/kg (Group B 20 or 40 μg/kg (Group B 40 as pre-treatment. Five minutes later, the degree of sedation was assessed by the observer′s assessment of alertness scale (OAA/S. Induction of anesthesia was done with propofol (30 mg/10 s till the loss of response to verbal commands. Thereafter, rocuronium 1 mg/kg was administered and endotracheal intubation was performed 2 min later. OAA/S, propofol induction dose, heart rate, blood pressure, oxygen saturation and entropy (response and state were compared in the three groups. Statistical Analysis: Data was analyzed using ANOVA test with posthoc significance, Kruskal-Wallis test, Chi-square test and Fischer exact test. A P<0.05 was considered as significant. Results: The induction dose of propofol (mg/kg was observed to be 1.1±0.50 in Group F, 1.05±0.35 in Group B 20 and 1.18±0.41 in Group B40. Induction with propofol occurred at higher entropy values on pre-treatment with both fentanyl as well as butorphanol. Hemodynamic variables were comparable in all the three groups. Conclusion: Butorphanol 20 μg/kg and 40 μg/kg reduce the induction requirement of propofol, comparable to that of fentanyl 2 μg/kg, and confer hemodynamic stability at induction and intubation.

  11. Management of patient dose in radiology in the UK

    International Nuclear Information System (INIS)

    Martin, C. J.

    2011-01-01

    Programmes to manage patient dose in radiology are becoming a higher priority as the number of imaging examinations and the proportion of higher dose computed tomography (CT) and complex interventional procedures all continue to rise. Such programmes have a number of components and their implementation in UK hospitals, which have been developing such programmes over two decades, is described. As part of any programme to manage patient doses, elements should be in place for both justification and optimisation. The system for justification needs to be robust in order to minimise the number of unnecessary procedures and requires the provision of training in radiation protection for medical and other staff to ensure that they understand the risks. Optimisation of X-ray techniques requires performance tests on equipment at installation and regularly thereafter, linked to surveys of patient doses. Confirming the performance of the available options on fluoroscopy and CT equipment is essential and the information obtained should be available to radiographers and radiologists, so they can make informed choices in developing imaging protocols. Patient doses should be compared with diagnostic reference levels set in terms of measured dose quantities to allow the identification of equipment that is giving higher doses. Taking the next step of analysing results to determine the reasons for high doses is crucial and requires a link with the equipment performance tests and an understanding of the underlying physics. Medical physics services play an important role at the hub of the dose management programme for carrying out tests, organising surveys, making recommendations on optimisation strategies and training other staff in radiation protection, performance testing and dose reduction. Programmes for management of patient doses in UK hospitals were first set up in the late 1980's by medical physicists and have been developed since that time to keep pace with the developments in

  12. Three-dimensional electron-beam dose calculations

    International Nuclear Information System (INIS)

    Shiu, A.S.

    1988-01-01

    The MDAH pencil-beam algorithm developed by Hogstrom et al (1981) has been widely used in clinics for electron-beam dose calculations for radiotherapy treatment planning. The primary objective of this research was to address several deficiencies of that algorithm and to develop an enhanced version. Two enhancements were incorporated into the pencil-beam algorithm; one models fluence rather than planar fluence, and the other models the bremsstrahlung dose using measured beam data. Comparisons of the resulting calculated dose distributions with measured dose distributions for several test phantoms have been made. From these results it is concluded (1) that the fluence-based algorithm is more accurate to use for the dose calculation in an inhomogeneous slab phantom, and (2) the fluence-based calculation provides only a limited improvement to the accuracy the calculated dose in the region just downstream of the lateral edge of an inhomogeneity. A pencil-beam redefinition model was developed for the calculation of electron-beam dose distributions in three dimensions

  13. Larvicidal activity and in vitro effects of green tea (Camellia sinensis L. water infusion

    Directory of Open Access Journals (Sweden)

    Žabar, A.

    2013-12-01

    Full Text Available In this study green tea water infusion was tested on Drosophila melanogaster wild-type larvae in vivo, also an in vitro antihemolytic and hemolytic tests were performed. Three different concentrations were used 7.5 mg/ml, 37.5 mg/ml and 75 mg/ml, the lowest dose representing the recommended dose followed by five times and ten times higher doses. Effect of these three concentrations was monitored and tested in vivo on Drosophila melanogaster (Meigen, 1830 wt (wild type larval development and surviving. All three concentrations showed toxic effect for larvae, with toxicity being increased in dose – depended manner. The time needed for larvae to fully develop was delayed. This decrease of developmental time was in dose – dependent manner, too. Amount of hemolysis caused by the lowest concentration was very small when compared with the percent of spontaneous hemolysis. Other two higher concentrations, 37.5 mg/ml and 75 mg/ml, showed higher hemolytic effect. During the four hour incubation period percent of hemolysis grew in time – dependent manner. The highest hemolytic effect was recorded for the concentration of 37.5 mg/ml. Antihemolytic test showed that the lowest concentration had the highest inhibitory effect to H2O2 induced hemolysis. The 37.5 mg/ml and 75 mg/ml concentrations had lower inhibitory effect when compared with the dose of 7.5 mg/ml. According to our study it can be concluded that the high concentrations of green tea water infusion exhibit larvicidal activity against D. melanogaster larvae, don't have protective effect to RBC membrane and cause greater hemolysis.

  14. Dose specification for radiation therapy: dose to water or dose to medium?

    International Nuclear Information System (INIS)

    Ma, C-M; Li Jinsheng

    2011-01-01

    The Monte Carlo method enables accurate dose calculation for radiation therapy treatment planning and has been implemented in some commercial treatment planning systems. Unlike conventional dose calculation algorithms that provide patient dose information in terms of dose to water with variable electron density, the Monte Carlo method calculates the energy deposition in different media and expresses dose to a medium. This paper discusses the differences in dose calculated using water with different electron densities and that calculated for different biological media and the clinical issues on dose specification including dose prescription and plan evaluation using dose to water and dose to medium. We will demonstrate that conventional photon dose calculation algorithms compute doses similar to those simulated by Monte Carlo using water with different electron densities, which are close (<4% differences) to doses to media but significantly different (up to 11%) from doses to water converted from doses to media following American Association of Physicists in Medicine (AAPM) Task Group 105 recommendations. Our results suggest that for consistency with previous radiation therapy experience Monte Carlo photon algorithms report dose to medium for radiotherapy dose prescription, treatment plan evaluation and treatment outcome analysis.

  15. Electron dose map inversion based on several algorithms

    International Nuclear Information System (INIS)

    Li Gui; Zheng Huaqing; Wu Yican; Fds Team

    2010-01-01

    The reconstruction to the electron dose map in radiation therapy was investigated by constructing the inversion model of electron dose map with different algorithms. The inversion model of electron dose map based on nonlinear programming was used, and this model was applied the penetration dose map to invert the total space one. The realization of this inversion model was by several inversion algorithms. The test results with seven samples show that except the NMinimize algorithm, which worked for just one sample, with great error,though,all the inversion algorithms could be realized to our inversion model rapidly and accurately. The Levenberg-Marquardt algorithm, having the greatest accuracy and speed, could be considered as the first choice in electron dose map inversion.Further tests show that more error would be created when the data close to the electron range was used (tail error). The tail error might be caused by the approximation of mean energy spectra, and this should be considered to improve the method. The time-saving and accurate algorithms could be used to achieve real-time dose map inversion. By selecting the best inversion algorithm, the clinical need in real-time dose verification can be satisfied. (authors)

  16. Influence of model based iterative reconstruction algorithm on image quality of multiplanar reformations in reduced dose chest CT

    International Nuclear Information System (INIS)

    Barras, Heloise; Dunet, Vincent; Hachulla, Anne-Lise; Grimm, Jochen; Beigelman-Aubry, Catherine

    2016-01-01

    Model-based iterative reconstruction (MBIR) reduces image noise and improves image quality (IQ) but its influence on post-processing tools including maximal intensity projection (MIP) and minimal intensity projection (mIP) remains unknown. To evaluate the influence on IQ of MBIR on native, mIP, MIP axial and coronal reformats of reduced dose computed tomography (RD-CT) chest acquisition. Raw data of 50 patients, who underwent a standard dose CT (SD-CT) and a follow-up RD-CT with a CT dose index (CTDI) of 2–3 mGy, were reconstructed by MBIR and FBP. Native slices, 4-mm-thick MIP, and 3-mm-thick mIP axial and coronal reformats were generated. The relative IQ, subjective IQ, image noise, and number of artifacts were determined in order to compare different reconstructions of RD-CT with reference SD-CT. The lowest noise was observed with MBIR. RD-CT reconstructed by MBIR exhibited the best relative and subjective IQ on coronal view regardless of the post-processing tool. MBIR generated the lowest rate of artefacts on coronal mIP/MIP reformats and the highest one on axial reformats, mainly represented by distortions and stairsteps artifacts. The MBIR algorithm reduces image noise but generates more artifacts than FBP on axial mIP and MIP reformats of RD-CT. Conversely, it significantly improves IQ on coronal views, without increasing artifacts, regardless of the post-processing technique

  17. Retrospective dose assessment for the population living in areas of local fallout from the Semipalatinsk nuclear test site. Part 1: external exposure

    International Nuclear Information System (INIS)

    Gordeev, Konstantin; Shinkarev, Sergey; Ilyin, Leonid; Bouville, Andre; Luckyanov, Nickolas; Simon, Steven L.; Hoshi, Masaharu

    2006-01-01

    A short analysis of all 111 atmospheric events conducted at the Semipalatinsk Test Site (STS) in 1949-1962 with regard to significant off-site exposure (more than 5 mSv of the effective dose during the first year after the explosion) has been made. The analytical method used to assess external exposure to the residents living in settlements near the STS is described. This method makes used of the archival data on the radiological conditions, including the measurements of exposure rate. Special attention was given to the residents of Dolon and Kanonerka villages exposed mainly as a result of the first test, detonated on August 29, 1949. For the residents of those settlements born in 1935, the dose estimates calculated according to the analytical method, are compared to those derived from the thermoluminescence measurements in bricks and electron paramagnetic resonance measurements in teeth. The methods described in this paper were used for external dose assessment for the cohort members at an initial stage of an ongoing epidemiological study conducted by the U.S. National Cancer Institute in the Republic of Kazakhstan. Recently revised methods and estimates of external exposure for that cohort are given in another paper (Simon et al.) in this conference. (author)

  18. Effects of co-treatment with mirtazapine and low doses of risperidone on immobility time in the forced swimming test in mice.

    Science.gov (United States)

    Rogóż, Zofia

    2010-01-01

    The aim of the present study was to examine the effect of mirtazapine (MIR) and risperidone (an atypical antipsychotic drug), given separately or jointly, on immobility time in the forced swimming test in male C57BL/6J mice. Fluoxetine (FLU) was used as a reference drug. MIR (2.5, 5 and 10 mg/kg) and FLU (5 and 10 mg/kg), or risperidone in low doses (0.05 and 0.1 mg/kg) given alone did not change the immobility time of mice in the forced swimming test. Joint administration of MIR (5 and 10 mg/kg) or FLU (10 mg/kg) and risperidone (0.1 mg/kg) produced antidepressant-like activity in the forced swimming test. WAY100636 (a 5-HT(1A) receptor antagonist) inhibited, while yohimbine (an α(2)-adrenergic receptor antagonist) potentiated the antidepressant-like effect induced by co-administration of MIR and risperidone. Active behavior in that test did not reflect an increase in general activity, since combined administration of antidepressants and risperidone failed to enhance the locomotor activity of mice. The obtained results indicate that risperidone applied in a low dose enhances the antidepressant-like activity of MIR and that, among other mechanisms, 5-HT(1A)-, and α(2)-adrenergic receptors may play a role in this effect.

  19. Summary of dosimetry, pathology, and dose response for bone sarcomas in beagles injected with radium-226

    International Nuclear Information System (INIS)

    Wrenn, M.E.; Taylor, G.N.; Stevens, W.

    1986-01-01

    In the completed 226 Ra portion of a 30-year-long experiment to determine the relative radiotoxicity of injected 226 Ra and 239 Pu, 42 of 116 animals injected with 226 Ra developed 63 bone sarcomas; none were observed in 44 controls. Average alpha plus beta dose to the skeleton to death was calculated on the basis of mathematical functions developed from sequential measurements of radium and radon retention in each dog. Bone sarcomas were identified radiographically or clinically, with subsequent histopathological confirmation and classification. Most primary bone tumors were classified as osteosarcomas if osteoid arose from a malignant stroma. The dose-response curve over the six lowest injected dose levels fits well to a linear, no-threshold, least squares fit, through a control incidence of 0.8%, and with a slope of 0.042% incidence per rad. 19 refs., 5 figs., 2 tabs

  20. Deep learning enables reduced gadolinium dose for contrast-enhanced brain MRI.

    Science.gov (United States)

    Gong, Enhao; Pauly, John M; Wintermark, Max; Zaharchuk, Greg

    2018-02-13

    There are concerns over gadolinium deposition from gadolinium-based contrast agents (GBCA) administration. To reduce gadolinium dose in contrast-enhanced brain MRI using a deep learning method. Retrospective, crossover. Sixty patients receiving clinically indicated contrast-enhanced brain MRI. 3D T 1 -weighted inversion-recovery prepped fast-spoiled-gradient-echo (IR-FSPGR) imaging was acquired at both 1.5T and 3T. In 60 brain MRI exams, the IR-FSPGR sequence was obtained under three conditions: precontrast, postcontrast images with 10% low-dose (0.01mmol/kg) and 100% full-dose (0.1 mmol/kg) of gadobenate dimeglumine. We trained a deep learning model using the first 10 cases (with mixed indications) to approximate full-dose images from the precontrast and low-dose images. Synthesized full-dose images were created using the trained model in two test sets: 20 patients with mixed indications and 30 patients with glioma. For both test sets, low-dose, true full-dose, and the synthesized full-dose postcontrast image sets were compared quantitatively using peak-signal-to-noise-ratios (PSNR) and structural-similarity-index (SSIM). For the test set comprised of 20 patients with mixed indications, two neuroradiologists scored blindly and independently for the three postcontrast image sets, evaluating image quality, motion-artifact suppression, and contrast enhancement compared with precontrast images. Results were assessed using paired t-tests and noninferiority tests. The proposed deep learning method yielded significant (n = 50, P 5 dB PSNR gains and >11.0% SSIM). Ratings on image quality (n = 20, P = 0.003) and contrast enhancement (n = 20, P deep learning method, gadolinium dose can be reduced 10-fold while preserving contrast information and avoiding significant image quality degradation. 3 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  1. Vitamin E can improve behavioral tests impairment, cell loss, and dendrite changes in rats' medial prefrontal cortex induced by acceptable daily dose of aspartame.

    Science.gov (United States)

    Rafati, Ali; Noorafshan, Ali; Jahangir, Mahboubeh; Hosseini, Leila; Karbalay-Doust, Saied

    2018-01-01

    Aspartame is an artificial sweetener used in about 6000 sugar-free products. Aspartame consumption could be associated with various neurological disorders. This study aimed to evaluate the effect of aspartame onmedial Prefrontal Cortex (mPFC) as well as neuroprotective effects of vitamin E. The rats were divided into seven groups, including distilled water, corn oil, vitamin E (100mg/kg/day), and low (acceptable daily dose) and high doses of aspartame (40 and 200mg/kg/day) respectively, with or without vitamin E consumption, for 8 weeks. Behavioral tests were recorded and the brain was prepared for stereological assessments. Novel objects test and eight-arm radial maze showed impairmentoflong- and short-termmemoriesin aspartame groups. Besides, mPFC volume, infralimbic volume, neurons number, glial cells number, dendrites length per neuron,and number of spines per dendrite length were decreased by 7-61% in the rats treated with aspartame. However, neurons' number, glial cells number, and rats' performance in eight-arm radial mazes were improved by concomitant consumption of vitamin E and aspartame. Yet, the mPFC volume and infralimbic cortex were protected only in the rats receiving the low dose of aspartame+vitamin E. On the other hand, dendrites length, spines number,and novel object recognition were not protected by treatment with vitamin E+aspartame. The acceptable daily dose or higher doses of aspartame could induce memory impairments and cortical cells loss in mPFC. However, vitamin E could ameliorate some of these changes. Copyright © 2017 Elsevier GmbH. All rights reserved.

  2. Responses of rat R-1 cells to low dose rate gamma radiation and multiple daily dose fractions

    International Nuclear Information System (INIS)

    Kal, H.B.; Bijman, J.Th.

    1981-01-01

    Multifraction irradiation may offer the same therapeutic gain as continuous irradiation. Therefore, a comparison of the efficacy of low dose rate irradiation and multifraction irradiation was the main objective of the experiments to be described. Both regimens were tested on rat rhabdomyosarcoma (R-1) cells in vitro and in vivo. Exponentially growing R-1 cells were treated in vitro by a multifraction irradiation procedure with dose fractions of 2 Gy gamma radiation and time intervals of 1 to 3 h. The dose rate was 1.3 Gy.min -1 . The results indicate that multifractionation of the total dose is more effective with respect to cell inactivation than continuous irradiation. (Auth.)

  3. Pulmonary Nodule Volumetry at Different Low Computed Tomography Radiation Dose Levels With Hybrid and Model-Based Iterative Reconstruction: A Within Patient Analysis.

    Science.gov (United States)

    den Harder, Annemarie M; Willemink, Martin J; van Hamersvelt, Robbert W; Vonken, Evertjan P A; Schilham, Arnold M R; Lammers, Jan-Willem J; Luijk, Bart; Budde, Ricardo P J; Leiner, Tim; de Jong, Pim A

    2016-01-01

    The aim of the study was to determine the effects of dose reduction and iterative reconstruction (IR) on pulmonary nodule volumetry. In this prospective study, 25 patients scheduled for follow-up of pulmonary nodules were included. Computed tomography acquisitions were acquired at 4 dose levels with a median of 2.1, 1.2, 0.8, and 0.6 mSv. Data were reconstructed with filtered back projection (FBP), hybrid IR, and model-based IR. Volumetry was performed using semiautomatic software. At the highest dose level, more than 91% (34/37) of the nodules could be segmented, and at the lowest dose level, this was more than 83%. Thirty-three nodules were included for further analysis. Filtered back projection and hybrid IR did not lead to significant differences, whereas model-based IR resulted in lower volume measurements with a maximum difference of -11% compared with FBP at routine dose. Pulmonary nodule volumetry can be accurately performed at a submillisievert dose with both FBP and hybrid IR.

  4. Measurements of the Cosmic Rays Dose at Different Altitudes of Iran

    International Nuclear Information System (INIS)

    Faghihi, R.; Mehdizadeh, S.; Jafarizadeh, M.; Sina, S.; Zehtabian, M.; Taheri, M.

    2012-01-01

    The amount of cosmic rays varies widely with the altitude, latitude and longitude in each region. In this study, the radiation doses due to the cosmic rays were estimated in two steps: in the first step, the neutron and gamma components of the radiation dose were measured for a roundtrip flight on 3 flight routes (Shiraz-Asaluye, Asaluye-Rasht and Shiraz-Mashhad) using a gamma-tracer photon detector and a Thyac 190 N, neutron detector. The minimum values of the measured gamma and neutron doses of 0.15 and 0.04μSv were measured on the Asaluyeh-Shiraz route at the lowest altitude of 19000 ft, while for Rasht-Asaluyeh route at an altitude of 35000 ft those values were found to be 2.52 and 1.09 mSv, respectively. In the second step, a number of air crew members were equipped with thermoluminescence dosimeters (TLD cards) for evaluating the gamma dose and polycarbonate dosimeters (SSNTD) for assessing the neutron dose for one year. The measured value of the annual effective dose received by the crew ranged between 0.5 mSv/y and 1.16 mSv/y, with an average of 0.9 mSv/y for the gamma component and between 0.37 mSv/y and 0.77 mSv/y with an average of 0.61 mSv/y for the neutron component. The results of this investigation are comparable with the investigations that have been conducted in other countries. For instance in UK, the reported annual effective dose of air crew is about 2 mSv, and in Canada, it is estimated to be between 1 to 5 mSv, depending on the flight situations (such as the latitude and longitude of the cities, the flight altitude, etc).

  5. SU-F-J-133: Adaptive Radiation Therapy with a Four-Dimensional Dose Calculation Algorithm That Optimizes Dose Distribution Considering Breathing Motion

    Energy Technology Data Exchange (ETDEWEB)

    Ali, I; Algan, O; Ahmad, S [University of Oklahoma Health Sciences, Oklahoma City, OK (United States); Alsbou, N [University of Central Oklahoma, Edmond, OK (United States)

    2016-06-15

    Purpose: To model patient motion and produce four-dimensional (4D) optimized dose distributions that consider motion-artifacts in the dose calculation during the treatment planning process. Methods: An algorithm for dose calculation is developed where patient motion is considered in dose calculation at the stage of the treatment planning. First, optimal dose distributions are calculated for the stationary target volume where the dose distributions are optimized considering intensity-modulated radiation therapy (IMRT). Second, a convolution-kernel is produced from the best-fitting curve which matches the motion trajectory of the patient. Third, the motion kernel is deconvolved with the initial dose distribution optimized for the stationary target to produce a dose distribution that is optimized in four-dimensions. This algorithm is tested with measured doses using a mobile phantom that moves with controlled motion patterns. Results: A motion-optimized dose distribution is obtained from the initial dose distribution of the stationary target by deconvolution with the motion-kernel of the mobile target. This motion-optimized dose distribution is equivalent to that optimized for the stationary target using IMRT. The motion-optimized and measured dose distributions are tested with the gamma index with a passing rate of >95% considering 3% dose-difference and 3mm distance-to-agreement. If the dose delivery per beam takes place over several respiratory cycles, then the spread-out of the dose distributions is only dependent on the motion amplitude and not affected by motion frequency and phase. This algorithm is limited to motion amplitudes that are smaller than the length of the target along the direction of motion. Conclusion: An algorithm is developed to optimize dose in 4D. Besides IMRT that provides optimal dose coverage for a stationary target, it extends dose optimization to 4D considering target motion. This algorithm provides alternative to motion management

  6. Total-dose hardness assurance for low earth orbit

    International Nuclear Information System (INIS)

    Maurer, R.H.; Suter, J.J.

    1987-01-01

    The Low Earth Orbit radiation environment has two significant characteristics that make laboratory simulation exposures difficult: (1) a low dose rate and (2) many cycles of low dose accumulation followed by dose-free annealing. Hardness assurance considerations for this environment are discussed and related to data from the testing of Advanced Low Power Schottky and High-speed CMOS devices

  7. Marked bengal pink. A dynamic test using marking doses; its value in jaundice diagnosis; Rose bengale marque. Epreuve dynamique a doses tracantes; sa valeur dans le diagnostic des icteres

    Energy Technology Data Exchange (ETDEWEB)

    Kellershohn, C; Desgrez, A [Commissariat a l' Energie Atomique, Service Frederic Joliot, Service de Biologie, Saclay (France).Centre d' Etudes Nucleaires; Caroli, J [Hopital Saint Antoine, 75 - Paris (France); Delaloye, B [Lausanne (Switzerland)

    1961-07-01

    The authors do a historic calling back of the differential study of jaundices thanks to the semi logarithmic gradients of expurgation of bromine sulphone-phthalein and thanks to the time of appearance of this material in the bile collected by duodenal tubing. They sum up likewise the foreign works which lead to take the place of this test, the outside count at the level of the head, the liver, and the abdomen after intravenous injection of a running dose of marked Rose Bengal. They specify the technical conditions of this test and report an experience which corroborate its value, its accuracy and the interest of its using in the different types of jaundices (hepatitis and obstructive types). (author) [French] Les auteurs font un rappel historique de l'etude differentielle des icteres grace aux pentes semi-logarithmiques d'epuration de la bromesulfonephtaleine et grace au temps d'apparition de cette substance dans la bile recueillie par tubage duodenal. Ils resument egalement les travaux etrangers qui tendent a substituer a cette epreuve le comptage externe au niveau de la tete, du foie et de l'abdomen, apres injection intraveineuse d'une dose tracante de rose bengale marque. Ils precisent les conditions techniques de cette epreuve et rapportent une experience qui confirme sa valeur, son exactitude et l'interet de son utilisation dans les differentes categories d'icteres par hepatite et par obstruction. (auteur)

  8. Quantitative radiation dose-response relationships for normal tissues in man - I. Gustatory tissues response during photon and neutron radiotherapy

    International Nuclear Information System (INIS)

    Mossman, K.L.

    1982-01-01

    Quantitative radiation dose-response curves for normal gustatory tissue in man were studied. Taste function, expressed as taste loss, was evaluated in 84 patients who were given either photon or neutron radiotherapy for tumors in the head and neck region. Patients were treated to average tumor doses of 6600 cGy (photon) or 2200 cGy intervals for photon patients and 320-cGy intervals for neutron patients during radiotherapy. The dose-response curves for photons and neutrons were analyzed by fitting a four-parameter logistic equation to the data. Photon and neutron curves differed principally in their relative position along the dose axis. Comparison of the dose-response curves were made by determination of RBE. At 320 cGy, the lowest neutron dose at which taste measurements were made, RBE = 5.7. If this RBE is correct, then the therapeutic gain factor may be equal to or less than 1, indicating no biological advantage in using neutrons over photons for this normal tissue. These studies suggest measurements of taste function and evaluation of dose-response relationships may also be useful in quantitatively evaluating the efficacy of chemical modifiers of radiation response such as hypoxic cell radiosensitizers and radioprotectors

  9. Quantitative comparison of the results obtained by the multiple-dose guinea pig maximization test and the non-radioactive murine local lymph-node assay for various biocides.

    Science.gov (United States)

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2005-07-01

    We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (microg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r=0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r=0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA.

  10. Quantitative comparison of the results obtained by the multiple-dose guinea pig maximization test and the non-radioactive murine local lymph-node assay for various biocides

    International Nuclear Information System (INIS)

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2005-01-01

    We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (μg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r = 0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r = 0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA

  11. Distribution of chloramphenicol to tissues, plasma and urine in pigs after oral intake of low doses.

    Science.gov (United States)

    Aspenström-Fagerlund, Bitte; Nordkvist, Erik; Törnkvist, Anna; Wallgren, Per; Hoogenboom, Ron; Berendsen, Bjorn; Granelli, Kristina

    2016-09-01

    Toxic effects of chloramphenicol in humans caused the ban for its use in food-producing animals in the EU. A minimum required performance level (MRPL) was specified for chloramphenicol at 0.3 μg kg(-1) for various matrices, including urine. In 2012, residues of chloramphenicol were found in pig urine and muscle without signs of illegal use. Regarding its natural occurrence in straw, it was hypothesised that this might be the source, straw being compulsory for use as bedding material for pigs in Sweden. Therefore, we investigated if low daily doses of chloramphenicol (4, 40 and 400 μg/pig) given orally during 14 days could result in residues in pig tissues and urine. A dose-related increase of residues was found in muscle, plasma, kidney and urine (showing the highest levels), but no chloramphenicol was found in the liver. At the lowest dose, residues were below the MRPL in all tissues except in the urine. However, in the middle dose, residues were above the MRPL in all tissues except muscle, and at the highest dose in all matrices. This study proves that exposure of pigs to chloramphenicol in doses occurring naturally in straw could result in residues above the MRPL in plasma, kidney and especially urine.

  12. A dose-escalation trial with the adaptive radiotherapy process as a delivery system in localized prostate cancer: Analysis of chronic toxicity

    International Nuclear Information System (INIS)

    Brabbins, Donald; Martinez, Alvaro; Yan Di; Lockman, David; Wallace, Michell; Gustafson, Gary; Chen, Peter; Vicini, Frank; Wong, John

    2005-01-01

    Purpose: To evaluate the validity of the chosen adaptive radiotherapy (ART) dose-volume constraints while testing the hypothesis that toxicity would not be greater at higher tumor dose levels. Materials and methods: In the ART dose escalation/selection trial, treatment was initiated with a generic planning target volume (PTV) formed as a 1-cm expansion of the clinical target volume (CTV). After the first week of therapy, the patient was replanned with a patient-specific PTV, constructed with CT and electronic portal images obtained in the first 4 days of treatment. A new multileaf collimator beam aperture was used. A minimum dose prescribed to the patient-specific PTV, ranging 70.2-79.2 Gy, was determined on the basis of the following rectal and bladder constraints: 82 Gy, 75.6 Gy, 75.6 Gy, and the maximum bladder dose is 85 Gy. A conformal four-field and/or intensity-modulated radiotherapy (IMRT) technique was used. Independent reviewers scored toxicities. The worst toxicity score seen was used as per the Common Toxicity Criteria grade scale (version 2). We divided the patients into three separate groups: 70.2-72 Gy, >72-75.6 Gy, and >75.6-79.2 Gy. Toxicities in each group were quantified and compared by the Pearson chi-squared test to validate our dose escalation/selection model. Grades 0, 1, 2, and 3 were censored as none vs. each category and none vs. any. Results: We analyzed patients with follow-up greater than 1 year. The mean duration of follow-up was 29 months (range, 12-46 months). We report on 280 patients, mean age 72 years (range, 51-87 years). Only 60 patients received adjuvant hormones. Mean pretreatment prostate-specific antigen level was 9.3 ng/mL (range, 0.6-120 ng/mL). Mean Gleason score was 6 (range, 3-9). The lowest dose level was given to 49 patients, the intermediate dose to 131 patients, and 100 patients received the highest dose escalation. One hundred eighty-one patients (65%) were treated to a prostate field only and 99 patients (35%) to

  13. Persistence of Meningococcal Antibodies and Response to a Third Dose After a Two-dose Vaccination Series with Investigational MenABCWY Vaccine Formulations in Adolescents.

    Science.gov (United States)

    Saez-Llorens, Xavier; Aguilera Vaca, Diana Catalina; Abarca, Katia; Maho, Emmanuelle; Han, Linda; Smolenov, Igor; Dull, Peter

    2015-10-01

    In a primary study, healthy adolescents received 2 doses (months 0/2) of 1 of the 4 investigational meningococcal ABCWY vaccine formulations, containing components of licensed quadrivalent glycoconjugate vaccine MenACWY-CRM, combined with different amounts of recombinant proteins (rMenB) and outer membrane vesicles (OMV) from a licensed serogroup B vaccine, or 2 doses of rMenB alone or 1 dose of MenACWY-CRM then a placebo. This phase 2 extension study evaluated antibody persistence up to 10 months after the 2-dose series and the immunogenicity and safety of a third dose (month 6). Immune responses against serogroups ACWY and serogroup B test strains were measured by serum bactericidal assay with human complement. At month 12, antibody persistence against serogroups ACWY in all 2-dose MenABCWY groups was at least comparable with the 1-dose MenACWY-CRM group. Bactericidal antibodies against most serogroup B test strains declined by month 6, then plateaued over the subsequent 6 months, with overall higher antibody persistence associated with OMV-containing formulations. A third MenABCWY vaccine dose induced robust immune responses against vaccine antigens, although antibody levels 6 months later were comparable with those observed 5 months after the 2-dose series. All investigational MenABCWY vaccines were well tolerated. Two or three doses of investigational MenABCWY vaccines elicited immune responses against serogroups ACWY that were at least comparable with those after 1 dose of MenACWY-CRM. After either vaccination series, investigational MenABCWY vaccine formulations containing OMV had the highest immunogenicity against most serogroup B test strains. No safety concerns were identified in this study.

  14. Toxicity tests based on predator-prey and competitive interactions between freshwater macroinvertebrates

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, E.J.; Blockwell, S.J.; Pascoe, D. [Univ. of Wales Coll. of Cardiff (United Kingdom)

    1994-12-31

    Simple multi-species toxicity tests based on the predation of Daphnia magna Straus by Hydra oligactis (Pallas) and competition between Gammarus pulex (L.) and Asellus aquaticus (L.) were used to determine the effects of three reference chemicals. Criteria examined included functional responses; time to first captures; handling times (predator/prey systems) and co-existence and growth. The tests which proved most practicable and sensitive (lowest observed effects 0.1, 21, and 80 {micro}g/l for lindane, copper and 3,4 dichloroaniline, respectively) were: (1) predator-prey tests: determining changes in the size-structure of predated D. magna populations and (2) competition tests: measuring the feeding rate of G. pulex competing with A. aquaticus, using a bioassay based on the time-response analysis of the consumption of Artemia salina eggs. The concentration of a chemical which affected particular response criteria was fond to depend on the test system employed. Results of the tests indicated that effects were often not dose-related and that a given criterion could be variously affected by different test concentrations. The complex pattern of responses may be explained in terms of the differential sensitivity of the interacting species and perhaps subtle alteration in strategies. The sensitivity of the bioassay endpoints is compared to those of a range of single species tests, and their value for predicting the impact pollutants may have upon natural freshwater ecosystems is discussed.

  15. CT dose management

    International Nuclear Information System (INIS)

    Zasheva, Ts.; Georgiev, E.; Kirova, G.

    2013-01-01

    Full text: Introduction: In recent decades Computed Tomography established itself as one of the most common study with a very wide range of applications and techniques of scanning. Best diagnostic value of the method resist to the risks of ionizing radiation, as statistics show that CT is one of the main sources of continuously increasing dose to the population. What you will learn: The physical parameters of the X-ray tube and the principles of image reconstruction; The relationship between variables parameters and the received dose; The ratio between the force and voltage of the current to the image quality, Influence of the used contrast medium to the physical properties of the image, The ratio of patient BMI to image processing, Effective use of knowledge for the optimal CT protocol. Discussions: The goal to reduce the dose received by the patient during a CT scan while keeping the diagnostic quality of the image puts to the test as handset X-ray producers and technicians who need to master the technique of study protocol forming as well as to balance the harm - benefit ratio. Among the most popular techniques are these of dose modulation, low-dose computed tomography at the expense of a reduction of the current or voltage intensity, and control of the number of post-processing algorithms for the image reconstruction. Conclusion: The training of radiologists and X-ray technicians plays a major role in optimizing of technical parameters in view of the reduction of the dose for the patient, while maintaining the diagnostic quality of the image

  16. EcoDoses - Improving radiological assessment of doses to man from terrestrial ecosystems. A status report for the NKS-B project 2005

    International Nuclear Information System (INIS)

    Nielsen, Sven P.; Andersson, Kasper; Thoerring, H.

    2006-04-01

    Considerable variations in activity concentrations in milk of 137 Cs and 90 Sr were observed between countries or regions due to precipitation patterns, soil types and inhomogeneity of Chernobyl fallout. Time trends indicate that factors influencing ecological half-lives for 90 Sr are not the same as for 137 Cs in the pasturemilk system. Internal doses to Faroese people derive mainly from dairy products, lamb and potatoes. The largest doses were received from nuclear weapons fallout in the early 1960's. 137 Cs causes higher doses than 90Sr, and the regional variability is larger for 137 Cs than for 90 Sr. 137 Cs deposition maps were made of Sweden. Values of 137Cs deposition and precipitation were used in the calculations of Nuclear Weapons Fallout (NWF). The deposition of 137 Cs from the Chernobyl accident was calculated for western Sweden. Lowest levels of NWF 137 Cs deposition density were noted in the north-eastern and eastern Sweden and the highest levels in the western parts. The Chernobyl 137 Cs deposition is highest along the coast and lowest in the south-eastern part and along the middle. The calculated deposition from NWF and Chernobyl in western Sweden was compared to observed deposition and showed good agreement. Ecological halftimes of 137 Cs in perch in Finnish lakes vary by a factor of three. The longest halftime of 137 Cs in perch was 9 y and the shortest 3 y. Norwegian lakes differ from each other with respect to the rates of decrease of 137 Cs in fish. Ecological halftimes of 137 Cs in trout and Arctic char varied from 1 to 5 y. A more rapid reduction of 137 Cs in fish is found in certain Norwegian lakes compared to Finnish lakes. In two Norwegian lakes the 137Cs concentrations in trout remain at about 100 Bq/kg since 1990. The European decision support systems, ARGOS and RODOS, include foodchain modules with default parameters derived from southern Germany. Many parameters describing foodchain transfer are subject to considerable variation

  17. Rotational structure of the five lowest frequency fundamental vibrational states of dimethylsulfoxide

    Science.gov (United States)

    Cuisset, Arnaud; Drumel, Marie-Aline Martin; Hindle, Francis; Mouret, Gaël; Sadovskií, Dmitrií A.

    2013-10-01

    We report on the successful extended analysis of the high-frequency (200-700 GHz) part of the gas phase (sub)mm-wave spectra of dimethylsulfoxide (DMSO). The spectrum was recorded at 100 kHz resolution using a solid state subTHz spectrometer. The five lowest energy fundamental vibrational states of DMSO with frequencies below 400 cm-1 were observed as sidebands along with the main 0←0 band. Neglecting the internal rotation of methyls, our rotational Hamiltonian reproduced the spectrum to the subMHz accuracy. We have found that the asymmetric bending state ν23 is the only low frequency fundamental vibrational state with the "anomalous" rotational structure uncovered in Cuisset et al. [1]. dmsomw 2013-09-04 15:03

  18. Measurements of surgeons' exposure to ionizing radiation dose during intraoperative use of C-arm fluoroscopy.

    Science.gov (United States)

    Lee, Kisung; Lee, Kyoung Min; Park, Moon Seok; Lee, Boram; Kwon, Dae Gyu; Chung, Chin Youb

    2012-06-15

    Measurement of radiation dose from C-arm fluoroscopy during a simulated intraoperative use in spine surgery. OBJECTIVE.: To investigate scatter radiation doses to specific organs of surgeons during intraoperative use of C-arm fluoroscopy in spine surgery and to provide practical intraoperative guidelines. There have been studies that reported the radiation dose of C-arm fluoroscopy in various procedures. However, radiation doses to surgeons' specific organs during spine surgery have not been sufficiently examined, and the practical intraoperative radioprotective guidelines have not been suggested. Scatter radiation dose (air kerma rate) was measured during the use of a C-arm on an anthropomorphic chest phantom on an operating table. Then, a whole body anthropomorphic phantom was located besides the chest phantom to simulate a surgeon, and scatter radiation doses to specific organs (eye, thyroid, breast, and gonads) and direct radiation dose to the surgeon's hand were measured using 4 C-arm configurations (standard, inverted, translateral, and tube translateral). The effects of rotating the surgeon's head away from the patient and of a thyroid shield were also evaluated. Scatter radiation doses decreased as distance from the patient increased during C-arm fluoroscopy use. The standard and translateral C-arm configurations caused lower scatter doses to sensitive organs than inverted and tube translateral configurations. Scatter doses were highest for breast and lowest for gonads. The use of a thyroid shield and rotating the surgeon's head away from the patient reduced scatter radiation dose to the surgeon's thyroid and eyes. The direct radiation dose was at least 20 times greater than scatter doses to sensitive organs. The following factors could reduce radiation exposure during intraoperative use of C-arm; (1) distance from the patient, (2) C-arm configuration, (3) radioprotective equipments, (4) rotating the surgeons' eyes away from the patient, and (5) avoiding

  19. The individual gamma dosemeter MD 20: Physical tests and evaluation tests

    International Nuclear Information System (INIS)

    Laureana, R.

    1981-03-01

    Tests on the digital individual dose ratemeter type DM 20 for gamma radiation measurement are presented. The aim of this testing is an evaluation of main physical characteristics under irradiation. Results are given in tables and graphs. Relative sensitivity versus dose rate is better than +14% for cobalt 60 photons with a good linearity. There is no detector saturation until 400 to 450 rad/h. The energy response is lower than +- 20% between 160 keV to 1.25 MeV. Autonomy is over 4000 hours. All informations: dose, dose rate and good working conditions are directly read [fr

  20. Dose-response relationships for carcinogens: a review

    International Nuclear Information System (INIS)

    Zeise, L.; Wilson, R.; Crouch, E.A.C.

    1987-01-01

    The authors review the experimental evidence for various shapes of dose-response relationships for carcinogens and summarize those experiments that give the most information on relatively low doses. A brief review of some models is given to illustrate the shapes of dose-response curve expected from them. Their major interest is in the use of dose-response relationships to estimate risks to humans at low doses, and so they pay special attention to experimentally observed and theoretically expected nonlinearities. There are few experimental examples of nonlinear dose-response relations in humans, but this may simply be due to the limitations in the data. The several examples in rodents, even though for high dose data, suggest that nonlinearity is common. In some cases such nonlinearities may be rationalized on the basis of the pharmacokinetics of the test compound or its metabolites

  1. Total dose and dose-rate effects on start-up current in anti-fuse FPGA

    International Nuclear Information System (INIS)

    Wang, J.; Wong, W.; McCollum, J.; Cronquist, B.; Katz, R.; Kleyner, I.; Kleyner, F.

    1999-01-01

    Radiation enhanced start-up current (RESC) in an anti-fuse FPGA, A1280A, is thoroughly investigated and a comprehensive transistor-level mechanism is proposed. Low dose-rate testing, appropriate for civilian space applications, and annealing at room temperature shows RESC to be negligible for the lot of parts tested with a fixed power supply slew rate. (authors)

  2. Investigation of tilted dose kernels for portal dose prediction in a-Si electronic portal imagers

    International Nuclear Information System (INIS)

    Chytyk, K.; McCurdy, B. M. C.

    2006-01-01

    The effect of beam divergence on dose calculation via Monte Carlo generated dose kernels was investigated in an amorphous silicon electronic portal imaging device (EPID). The flat-panel detector was simulated in EGSnrc with an additional 3.0 cm water buildup. The model included details of the detector's imaging cassette and the front cover upstream of it. To approximate the effect of the EPID's rear housing, a 2.1 cm air gap and 1.0 cm water slab were introduced into the simulation as equivalent backscatter material. Dose kernels were generated with an incident pencil beam of monoenergetic photons of energy 0.1, 2, 6, and 18 MeV. The orientation of the incident pencil beam was varied from 0 deg. to 14 deg. in 2 deg. increments. Dose was scored in the phosphor layer of the detector in both cylindrical (at 0 deg. ) and Cartesian (at 0 deg. -14 deg.) geometries. To reduce statistical fluctuations in the Cartesian geometry simulations at large radial distances from the incident pencil beam, the voxels were first averaged bilaterally about the pencil beam and then combined into concentric square rings of voxels. Profiles of the EPID dose kernels displayed increasing asymmetry with increasing angle and energy. A comparison of the superposition (tilted kernels) and convolution (parallel kernels) dose calculation methods via the χ-comparison test (a derivative of the γ-evaluation) in worst-case-scenario geometries demonstrated an agreement between the two methods within 0.0784 cm (one pixel width) distance-to-agreement and up to a 1.8% dose difference. More clinically typical field sizes and source-to-detector distances were also tested, yielding at most a 1.0% dose difference and the same distance-to-agreement. Therefore, the assumption of parallel dose kernels has less than a 1.8% dosimetric effect in extreme cases and less than a 1.0% dosimetric effect in most clinically relevant situations and should be suitable for most clinical dosimetric applications. The

  3. Radiation consequences of the nuclear tests on the Semipalatinsk test site

    International Nuclear Information System (INIS)

    Logachev, V.A.; Logacheva, L.A.

    2001-01-01

    In the paper the results of retrospective evaluation for radiation situation and radiation doses of population in the zones of the Semipalatinsk test site activity influence are presented. For the measurements the data obtained during analysis, study and summarizing of the archival materials including information on nuclear tests on this site and results of radiation surveys, those were carried out after each test were used. The information testifying most substantial environment contamination taking place after four surface explosions (29.08.1949, 24.09.1951, 12.08.1953, 24.08.1956) is presented as well. After these dose-forming explosions the irradiation doses of the population inhabiting out the regime zone have been exceeded the maximum permissible levels. Results of analysis of archival materials were used for assessment of doses of internal and external irradiation of residents of inhabited points situated on the both the territory of the Republic of Kazakhstan - mainly close to the test site - and the territories of a number of regions of the Russian Federation are locating on the little distance from the tests site

  4. Rapid, low dose X-ray diffractive imaging of the malaria parasite Plasmodium falciparum

    International Nuclear Information System (INIS)

    Jones, Michael W.M.; Dearnley, Megan K.; Riessen, Grant A. van; Abbey, Brian; Putkunz, Corey T.; Junker, Mark D.; Vine, David J.; McNulty, Ian; Nugent, Keith A.; Peele, Andrew G.; Tilley, Leann

    2014-01-01

    Phase-diverse X-ray coherent diffractive imaging (CDI) provides a route to high sensitivity and spatial resolution with moderate radiation dose. It also provides a robust solution to the well-known phase-problem, making on-line image reconstruction feasible. Here we apply phase-diverse CDI to a cellular sample, obtaining images of an erythrocyte infected by the sexual stage of the malaria parasite, Plasmodium falciparum, with a radiation dose significantly lower than the lowest dose previously reported for cellular imaging using CDI. The high sensitivity and resolution allow key biological features to be identified within intact cells, providing complementary information to optical and electron microscopy. This high throughput method could be used for fast tomographic imaging, or to generate multiple replicates in two-dimensions of hydrated biological systems without freezing or fixing. This work demonstrates that phase-diverse CDI is a valuable complementary imaging method for the biological sciences and ready for immediate application. - Highlights: • Phase-diverse coherent X-ray diffraction microscopy provides high-resolution and high-contrast images of intact biological samples. • Rapid nanoscale resolution imaging is demonstrated at orders of magnitude lower dose than previously possible. • Phase-diverse coherent X-ray diffraction microscopy is a robust technique for rapid, quantitative, and correlative X-ray phase imaging

  5. Rapid, low dose X-ray diffractive imaging of the malaria parasite Plasmodium falciparum

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Michael W.M., E-mail: michael.jones@latrobe.edu.au [ARC Centre of Excellence for Coherent X-Ray Science, Department of Physics, La Trobe University, Victoria 3086 (Australia); Dearnley, Megan K. [ARC Centre of Excellence for Coherent X-Ray Science, Department of Biochemistry and Molecular Biology, Bio21 Institute, The University of Melbourne, Victoria 3010 (Australia); Riessen, Grant A. van [ARC Centre of Excellence for Coherent X-Ray Science, Department of Physics, La Trobe University, Victoria 3086 (Australia); Abbey, Brian [ARC Centre of Excellence for Coherent X-Ray Science, Department of Physics, La Trobe University, Victoria 3086 (Australia); Melbourne Centre for Nanofabrication, Victoria 3168 (Australia); Putkunz, Corey T. [ARC Centre of Excellence for Coherent X-Ray Science, School of Physics, The University of Melbourne, Victoria 3010 (Australia); Junker, Mark D. [ARC Centre of Excellence for Coherent X-Ray Science, Department of Physics, La Trobe University, Victoria 3086 (Australia); Vine, David J. [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); McNulty, Ian [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); Centre for Nanoscale Materials, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Nugent, Keith A. [ARC Centre of Excellence for Coherent X-Ray Science, Department of Physics, La Trobe University, Victoria 3086 (Australia); Peele, Andrew G. [ARC Centre of Excellence for Coherent X-Ray Science, Department of Physics, La Trobe University, Victoria 3086 (Australia); Australian Synchrotron, 800 Blackburn Road, Clayton 3168 (Australia); Tilley, Leann [ARC Centre of Excellence for Coherent X-Ray Science, Department of Biochemistry and Molecular Biology, Bio21 Institute, The University of Melbourne, Victoria 3010 (Australia)

    2014-08-01

    Phase-diverse X-ray coherent diffractive imaging (CDI) provides a route to high sensitivity and spatial resolution with moderate radiation dose. It also provides a robust solution to the well-known phase-problem, making on-line image reconstruction feasible. Here we apply phase-diverse CDI to a cellular sample, obtaining images of an erythrocyte infected by the sexual stage of the malaria parasite, Plasmodium falciparum, with a radiation dose significantly lower than the lowest dose previously reported for cellular imaging using CDI. The high sensitivity and resolution allow key biological features to be identified within intact cells, providing complementary information to optical and electron microscopy. This high throughput method could be used for fast tomographic imaging, or to generate multiple replicates in two-dimensions of hydrated biological systems without freezing or fixing. This work demonstrates that phase-diverse CDI is a valuable complementary imaging method for the biological sciences and ready for immediate application. - Highlights: • Phase-diverse coherent X-ray diffraction microscopy provides high-resolution and high-contrast images of intact biological samples. • Rapid nanoscale resolution imaging is demonstrated at orders of magnitude lower dose than previously possible. • Phase-diverse coherent X-ray diffraction microscopy is a robust technique for rapid, quantitative, and correlative X-ray phase imaging.

  6. [Epidural anaesthesia: Simulated intravascular test dose with S(+) ketamine, lidocaine and adrenaline. A prospective, randomized, double blind and placebo controlled study].

    Science.gov (United States)

    Higueras, R; Errando, C L; Soriano-Bru, J L

    2015-02-01

    The use of a test dose in epidural anaesthesia is a safety recommendation. However specificity and sensitivity of the drugs used with this indication have been not conclusive. The main objective of this study was to compare the effectiveness and the adverse effects of a simulated intravascular test dose of adrenaline, lidocaine and S(+)-ketamine. A prospective, randomized, double blinded, placebo controlled study was designed. ASA I patients scheduled for elective surgery were included. These were randomized to the following study groups: S(+)-ketamine 0.5 mg.kg-1 (S+K group), 5% lidocaine 1.5 mg.kg-1 (L5% group), adrenaline 15μg (ADR group), and physiological saline 3 ml (SF group; control group). An evaluation was made during the first 15 minutes after the study drug was administered. Variables including heart rate (HR) systolic and diastolic blood pressure (sBP and dBP), mean arterial pressure (MAP), and SpO2 were recorded at 0 min (baseline) and at 2, 5, 8, 10 and 15 minutes after drug injection. An increase of at least 20 beats per minute (bpm) in relation to the baseline measurement was considered a positive result, as was an increase sBP >15 mmHg. The clinical effects described as related to iv injection of the study drugs recorded were: sedation-hypnosis, dizziness, nystagmus, metallic taste perception, perioral or facial paresthesias, tinnitus, as well as any other effect the patients mentioned. Sensitivity and specificity were calculated as was the percent increase in the parameters in order to see if these were clinically useful. A total of 80 patients, 20 per group, were included. The sBP, dBP, and MAP were significantly raised at the 2, 5, 8 and 10 minutes measurements in the S(+)K group compared to the rest of the groups (Padrenaline at the scheduled doses showed low sensitivity and specificity as a simulated iv epidural test dose. S(+)-ketamine could be a feasible marker after accidental iv injection during epidural anaesthesia or analgesia

  7. Computer simulation of 2D grain growth using a cellular automata model based on the lowest energy principle

    International Nuclear Information System (INIS)

    He Yizhu; Ding Hanlin; Liu Liufa; Shin, Keesam

    2006-01-01

    The morphology, topology and kinetics of normal grain growth in two-dimension were studied by computer simulation using a cellular automata (Canada) model based on the lowest energy principle. The thermodynamic energy that follows Maxwell-Boltzmann statistics has been introduced into this model for the calculation of energy change. The transition that can reduce the system energy to the lowest level is chosen to occur when there is more than one possible transition direction. The simulation results show that the kinetics of normal grain growth follows the Burke equation with the growth exponent m = 2. The analysis of topology further indicates that normal grain growth can be simulated fairly well by the present CA model. The vanishing of grains with different number of sides is discussed in the simulation

  8. Influence of radiation dose and dose-rate on modification of barley seed radiosensitivity by post-treatment with caffeine

    International Nuclear Information System (INIS)

    Sharma, G.J.

    1987-01-01

    Influence of radiation doses (100, 150 and 200 Gy) and dose-rates (1.27-0.023 Gy/Sec) on the modification of oxic and anoxic radiation damage by caffeine at different concentrations has been investigated using metabolizing barley seeds as test system. As the radiation dose increases from 100 to 200 Gy, the magnitude of oxic and anoxic damages increase at all the dose-rates. Caffeine is able to afford partial radioprotection against the oxic damage, at the same time potentiating the anoxic damage. However, caffeine effect against the oxic and anoxic components of damage depend largely upon the dose of radiation applied and also on the dose-rate used. The possible mechanism of action of caffeine in bringing about the differential modification of oxic and anoxic damages has been discussed. 19 refs., 2 tables. (author)

  9. Oral desensitization to milk: how to choose the starting dose!

    Science.gov (United States)

    Mori, Francesca; Pucci, Neri; Rossi, Maria Elisabetta; de Martino, Maurizio; Azzari, Chiara; Novembre, Elio

    2010-01-01

    Mori F, Pucci N, Rossi ME, de Martino M, Azzari C, Novembre E. Oral desensitization to milk: how to choose the starting dose! Pediatr Allergy Immunol 2010: 21: e450–e453. © 2009 John Wiley & Sons A/S A renewed interest in oral desensitization as treatment for food allergy has been observed in the last few years. We studied a novel method based on the end point skin prick test procedure to establish the starting dose for oral desensitization in a group of 30 children higly allergic to milk. The results (in terms of reactions to the first dose administered) were compared with a group of 20 children allergic to milk as well. Such control group started to swallow the same dose of 0.015 mg/ml of milk. None reacted to the first dose when administered according to the end point skin prick test. On the other side, ten out of 20 children (50%) from the control group showed mild allergic reactions to the first dose of milk. In conclusion the end point skin prick test procedure results safe and easy to be performed in each single child in order to find out the starting dose for oral desensitization to milk, also by taking into account the individual variability. PMID:19624618

  10. A comparison of entrance skin dose delivered by clinical angiographic c-arms using the real-time dosimeter: the MOSkin

    International Nuclear Information System (INIS)

    Thorpe, Nathan K.; Cutajar, Dean; Lian, Cheryl; Rosenfeld, Anatoly; Pitney, Mark; Friedman, Daniel; Perevertaylo, Vladimir

    2016-01-01

    Coronary angiography is a procedure used in the diagnosis and intervention of coronary heart disease. The procedure is often considered one of the highest dose diagnostic procedures in clinical use. Despite this, there is minimal use of dosimeters within angiographic catheterisation laboratories due to challenges resulting from their implementation. The aim of this study was to compare entrance dose delivery across locally commissioned c-arms to assess the need for real-time dosimetry solutions during angiographic procedures. The secondary aim of this study was to establish a calibration method for the MOSkin dosimeter that accurately produces entrance dose values from the clinically sampled beam qualities and energies. The MOSkin is a real-time dosimeter used to measure the skin dose delivered by external radiation beams. The suitability of the MOSkin for measurements in the angiographic catheterisation laboratory was assessed. Measurements were performed using a 30 × 30 × 30cm 3 PMMA phantom positioned at the rotational isocenter of the c-arm gantry. The MOSkin calibration factor was established through comparison of the MOSkin response to EBT2 film response. Irradiation of the dosimeters was performed using several clinical beam qualities ranging in energy from 70 to 105 kVp. A total of four different interventional c-arm machines were surveyed and compared using the MOSkin dosimeter. The phantom was irradiated from a normal angle of incidence using clinically relevant protocols, field sizes and source to image detector distance values. The MOSkin was observed to be radiotranslucent to the c-arm beam in all clinical environments. The MOSkin response was reproducible to within 2 % of the average value across repeated measurements for each beam setting. There were large variations in entrance dose delivery to the phantom between the different c-arm machines with the highest observed cine-acquisition entrance dose rate measuring 326 % higher than the lowest

  11. TU-PIS-Exhibit Hall-01: CT Dose Optimization Technologies II

    International Nuclear Information System (INIS)

    Driesser, I; Angel, E

    2014-01-01

    Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Siemens‘ Commitment to the Right Dose in Computed Tomography Presentation Time: 11:15 - 11:45 AM Providing sustainable clinical results at highest patient safety: This is the challenge in medical imaging. Especially for Computed Tomography this means applying not simply the lowest, but the right dose for sound diagnostic imaging. Consequently, Siemens is committed to deliver the right dose in CT. In order to reduce radiation to the right dose, the first step is to provide the right dose technology. Through decades of research and development in CT imaging, Siemens CT has constantly introduced new ideas leading to a comprehensive portfolio of unique CARE technologies to deliver the right dose. For example automated kV adjustment based on patient size and the clinical question with CARE kV and three generations of iterative reconstruction. Based on the right dose technology, the next step is to actually scan at the right dose. For this, it is key to know the right dose targets for every examination. Siemens continuously involves CT experts to push developments further and outline how users can best adapt their procedures to the right dose. For users to know whether they met the right dose targets, it is therefore important to understand and monitor the actual absolute dose values. All scanners are delivered with defined default protocols which automatically use the available right dose technologies. Finally, to deliver the right dose not just in singular cases, but ideally to patients everywhere, organizations need then to manage dose across

  12. Dose- and age-dependent cardiovascular mortality among inhabitants of the Chornobyl contaminated areas. 1988-2010 observation period

    International Nuclear Information System (INIS)

    Buzunov, V.O.; Prikashchikova, K.Je.; Domashevs'ka, T.Je.; Kostyuk, G.V.; Gubyina, Yi.G.; Tereshchenko, S.O.

    2014-01-01

    Cardiovascular mortality among inhabitants of contaminated areas of Ukraine is dependent on the total cumulative effective doses and age at the time of the Chornobyl accident. It is proved by a significantly higher (p < 0.05) mortality in people exposed to 21.00-50.0 mSv radiation doses compared to those having 5.6-20.99 mSv exposures. Mortality was significantly higher (p < 0.05) in age groups with higher doses as opposed to those with low ones. Maximum mortality was observed among inhabitants aged 40-60, while the lowest death rate - in patients younger than 18 years old. The data obtained also suggest that the radiation factor can be considered here as one accelerating the aging and pathophysiological abnormalities in survivors. Coronary heart disease, cerebrovascular disease, arterial hypertension, diseases of arteries, arterioles and capillaries are the main causes of death from cardiovascular disease in people under investigation

  13. Emphysema quantification and lung volumetry in chest X-ray equivalent ultralow dose CT - Intra-individual comparison with standard dose CT.

    Science.gov (United States)

    Messerli, Michael; Ottilinger, Thorsten; Warschkow, René; Leschka, Sebastian; Alkadhi, Hatem; Wildermuth, Simon; Bauer, Ralf W

    2017-06-01

    To determine whether ultralow dose chest CT with tin filtration can be used for emphysema quantification and lung volumetry and to assess differences in emphysema measurements and lung volume between standard dose and ultralow dose CT scans using advanced modeled iterative reconstruction (ADMIRE). 84 consecutive patients from a prospective, IRB-approved single-center study were included and underwent clinically indicated standard dose chest CT (1.7±0.6mSv) and additional single-energy ultralow dose CT (0.14±0.01mSv) at 100kV and fixed tube current at 70mAs with tin filtration in the same session. Forty of the 84 patients (48%) had no emphysema, 44 (52%) had emphysema. One radiologist performed fully automated software-based pulmonary emphysema quantification and lung volumetry of standard and ultralow dose CT with different levels of ADMIRE. Friedman test and Wilcoxon rank sum test were used for multiple comparison of emphysema and lung volume. Lung volumes were compared using the concordance correlation coefficient. The median low-attenuation areas (LAA) using filtered back projection (FBP) in standard dose was 4.4% and decreased to 2.6%, 2.1% and 1.8% using ADMIRE 3, 4, and 5, respectively. The median values of LAA in ultralow dose CT were 5.7%, 4.1% and 2.4% for ADMIRE 3, 4, and 5, respectively. There was no statistically significant difference between LAA in standard dose CT using FBP and ultralow dose using ADMIRE 4 (p=0.358) as well as in standard dose CT using ADMIRE 3 and ultralow dose using ADMIRE 5 (p=0.966). In comparison with standard dose FBP the concordance correlation coefficients of lung volumetry were 1.000, 0.999, and 0.999 for ADMIRE 3, 4, and 5 in standard dose, and 0.972 for ADMIRE 3, 4 and 5 in ultralow dose CT. Ultralow dose CT at chest X-ray equivalent dose levels allows for lung volumetry as well as detection and quantification of emphysema. However, longitudinal emphysema analyses should be performed with the same scan protocol and

  14. Dose enhancement in a room cobalt-60 source

    International Nuclear Information System (INIS)

    Simons, M.; Pease, R.L.; Fleetwood, D.M.; Schwank, J.R.; Krzesniak, M.

    1997-01-01

    A room Co-60 source was characterized using TLDs and pMOS RADFETs. Dose enhancement was measured using RADFETs with and without gold- flashed kovar lids. A methodology was developed to predict dose enhancement vs position and test configuration

  15. Potential energies for the two lowest 1A' electronic states of H3+

    International Nuclear Information System (INIS)

    Ichihara, Akira; Yokoyama, Keiichi; Iwamoto, Osamu

    1998-11-01

    Potential energies for the two lowest 1 A' states of H 3 + at 701 different spatial geometries are tabulated. These energies have been calculated by the ab initio full configuration interaction method with a (8s6p2d1f) Gaussian type basis set. Features of avoided crossing of two surfaces as well as the potential well in the ground state can be produced by interpolating calculated energies. These ab initio energies are expressed as a function of three internuclear distances in the range from 0.6 to 10.0 bohr, and they are applicable to the molecular dynamics study for the H + + H 2 system. (author)

  16. Research of z-axis geometric dose efficiency in multi-detector computed tomography

    International Nuclear Information System (INIS)

    Kim, You Hyun; Kim, Moon Chan

    2006-01-01

    With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for

  17. Dose evaluation in diagnostic for computerized tomography; Evaluacion de dosis en diagnostico por tomografia computarizada

    Energy Technology Data Exchange (ETDEWEB)

    Flores, W.; Borges, J.C.; Mota, H. [Universidad Federal de Rio de Janeiro, PEN/COPPE/UFRJ. Caixa Postal 68509. 21945-970 Rio de Janeiro (Brazil)

    1998-12-31

    The patients which are subjected to computerized tomography tests are exposed to relatively high doses given as result doses on organs that are not matter to test. It was realized a dose levels raising in patients subjected to tests by T C, utilizing to measure this magnitude, TLD-100 thermoluminescent dosemeters which were put directly on the patient, in eye regions, thyroid, breast and navel; founding doses fluctuating between 29.10-49.39 mGy in organs examined and dose values between 0.21-29.10 mGy for organs that no matter to test. The applications of ionizing radiations in medicine do not have dose limits, but paying attention to the radiological protection optimization principle, it is recommended the use of clothes to anti-rays protection for zones not examined, getting with this to reduce the level doses as low as possible, without this to diminish the test quality. (Author)

  18. SU-E-T-566: Neutron Dose Cloud Map for Compact ProteusONE Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Syh, J; Patel, B; Syh, J; Rosen, L; Wu, H [Willis-Knighton Medical Center, Shreveport, LA (United States)

    2015-06-15

    Purpose: To establish the base line of neutron cloud during patient treatment in our new compact Proteus One proton pencil beam scanning (PBS) system with various beam delivery gantry angles, with or without range shifter (RS) at different body sites. Pencil beam scanning is an emerging treatment technique, for the concerns of neutron exposure, this study is to evaluate the neutron dose equivalent per given delivered dose under various treatment conditions at our proton therapy center. Methods: A wide energy neutron dose equivalent detector (SWENDI-II, Thermo Scientific, MA) was used for neutron dose measurements. It was conducted in the proton therapy vault during beam was on. The measurement location was specifically marked in order to obtain the equivalent dose of neutron activities (H). The distances of 100, 150 and 200 cm at various locations are from the patient isocenter. The neutron dose was measured of proton energy layers, # of spots, maximal energy range, modulation width, field radius, gantry angle, snout position and delivered dose in CGE. The neutron dose cloud is reproducible and is useful for the future reference. Results: When distance increased the neutron equivalent dose (H) reading did not decrease rapidly with changes of proton energy range, modulation width or spot layers. For cranial cases, the average mSv/CGE was about 0.02 versus 0.032 for pelvis cases. RS will induce higher H to be 0.10 mSv/CGE in average. Conclusion: From this study, neutron per dose ratio (mSv/CGE) slightly depends upon various treatment parameters for pencil beams. For similar treatment conditions, our measurement demonstrates this value for pencil beam scanning beam has lowest than uniform scanning or passive scattering beam with a factor of 5. This factor will be monitored continuously for other upcoming treatment parameters in our facility.

  19. Comparison of absorbed dose of two protocols of tomographic scanning in PET/CT exams

    International Nuclear Information System (INIS)

    Paiva, F.G.

    2017-01-01

    Positron Emission Tomography (PET) associated with Computed Tomography (CT) allows the fusion of functional and anatomical images. When compared to other diagnostic techniques, PET-CT subjects patients to higher levels of radiation, because two modalities are used in a single exam. In this study, the doses absorbed in 19 patient organs from the tomographic scan were evaluated. Radiochromic films were correctly positioned in the Alderson anthropomorphic simulator, male version. For evaluation, two whole body scan protocols were compared. For evaluation, two whole body scan protocols were compared. An increase of up to 600% in the absorbed dose in the pituitary was observed when the protocols were compared, with the lowest observed increase of approximately 160% for the liver. It is concluded that the dose from CT in patients submitted to PET-CT scanning is higher in the protocol used for diagnosis. Considering the high cost of PET-CT exam, in many cases it is preferable that the CT examination is of diagnostic quality, and not only for anatomical mapping, an argument based on the Principle of Justification

  20. Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.

    Science.gov (United States)

    Duong, Phuong-Anh; Little, Brent P

    2014-08-01

    Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.