WorldWideScience

Sample records for low-to-moderate lead absorption

  1. Telomere length in children environmentally exposed to low-to-moderate levels of lead

    International Nuclear Information System (INIS)

    Pawlas, Natalia; Płachetka, Anna; Kozłowska, Agnieszka; Broberg, Karin; Kasperczyk, Sławomir

    2015-01-01

    Shorter relative telomere length in peripheral blood is a risk marker for some types of cancers and cardiovascular diseases. Several environmental hazards appear to shorten telomeres, and this shortening may predispose individuals to disease. The aim of the present cross-sectional study was to assess the effect of environmental exposure to lead on relative telomere length (rTL) in children. A cohort of 99 8-year-old children was enrolled from 2007–2010. Blood lead concentrations (B-Pb) were measured by graphite furnace atomic absorption spectrometry, and blood rTL was measured by quantitative PCR. The geometric mean of B-Pb was 3.28 μg/dl (range: 0.90–14.2), and the geometric mean of rTL was 1.08 (range: 0.49–2.09). B-Pb was significantly inversely associated with rTL in the children (r S = − 0.25, p = 0.013; in further analyses both log-transformed-univariate regression analysis β = − 0.13, p = 0.026, and R 2 adj 4%; and β = − 0.12, p = 0.056 when adjusting for mothers' smoking during pregnancy, Apgar score, mother's and father's ages at delivery, sex and mother's education, R 2 adj 12%, p = 0.011). The effect of lead remained significant in children without prenatal tobacco exposure (N = 87, r S = − 0.24, p = 0.024; in further analyses, β = − 0.13, p = 0.029, and R 2 adj 4%). rTL was not affected by sex, the concentrations of other elements in the blood (i.e., cadmium and selenium concentrations), or oxidative injury parameters (total antioxidant status, 8-hydroxydeoxyguanosine and thiobarbituric acid-reactive substances). Lead exposure in childhood appears to be associated with shorter telomeres, which might contribute to diseases, such as cardiovascular disease. The inverse association between blood lead level and the telomeres in children emphasizes the importance of further reducing lead levels in the environment. - Highlights: • This cross-sectional study analyzes the association between environmental lead exposure

  2. Telomere length in children environmentally exposed to low-to-moderate levels of lead

    Energy Technology Data Exchange (ETDEWEB)

    Pawlas, Natalia, E-mail: n-pawlas@wp.pl [Institute of Occupational Medicine and Environmental Health, PL 41-200 Sosnowiec (Poland); Płachetka, Anna [Department of Animal Physiology and Ecotoxicology, University of Silesia, Bankowa str. 9, 40-007 Katowice (Poland); Kozłowska, Agnieszka [Institute of Occupational Medicine and Environmental Health, PL 41-200 Sosnowiec (Poland); Broberg, Karin [Institute of Environmental Medicine, Unit of Metals & Health, Box 210, SE-171 77 Stockholm (Sweden); Kasperczyk, Sławomir [Department of Biochemistry, Medical University of Silesia, Katowice, SMDZ in Zabrze, 41-808 Zabrze (Poland)

    2015-09-01

    Shorter relative telomere length in peripheral blood is a risk marker for some types of cancers and cardiovascular diseases. Several environmental hazards appear to shorten telomeres, and this shortening may predispose individuals to disease. The aim of the present cross-sectional study was to assess the effect of environmental exposure to lead on relative telomere length (rTL) in children. A cohort of 99 8-year-old children was enrolled from 2007–2010. Blood lead concentrations (B-Pb) were measured by graphite furnace atomic absorption spectrometry, and blood rTL was measured by quantitative PCR. The geometric mean of B-Pb was 3.28 μg/dl (range: 0.90–14.2), and the geometric mean of rTL was 1.08 (range: 0.49–2.09). B-Pb was significantly inversely associated with rTL in the children (r{sub S} = − 0.25, p = 0.013; in further analyses both log-transformed-univariate regression analysis β = − 0.13, p = 0.026, and R{sup 2}adj 4%; and β = − 0.12, p = 0.056 when adjusting for mothers' smoking during pregnancy, Apgar score, mother's and father's ages at delivery, sex and mother's education, R{sup 2}adj 12%, p = 0.011). The effect of lead remained significant in children without prenatal tobacco exposure (N = 87, r{sub S} = − 0.24, p = 0.024; in further analyses, β = − 0.13, p = 0.029, and R{sup 2}adj 4%). rTL was not affected by sex, the concentrations of other elements in the blood (i.e., cadmium and selenium concentrations), or oxidative injury parameters (total antioxidant status, 8-hydroxydeoxyguanosine and thiobarbituric acid-reactive substances). Lead exposure in childhood appears to be associated with shorter telomeres, which might contribute to diseases, such as cardiovascular disease. The inverse association between blood lead level and the telomeres in children emphasizes the importance of further reducing lead levels in the environment. - Highlights: • This cross-sectional study analyzes the association between

  3. Low to moderate temperature nanolaminate heater

    Science.gov (United States)

    Eckels, J Del [Livermore, CA; Nunes, Peter J [Danville, CA; Simpson, Randall L [Livermore, CA; Hau-Riege, Stefan [Fremont, CA; Walton, Chris [Oakland, CA; Carter, J Chance [Livermore, CA; Reynolds, John G [San Ramon, CA

    2011-01-11

    A low to moderate temperature heat source comprising a high temperature energy source modified to output low to moderate temperatures wherein the high temperature energy source modified to output low to moderate temperatures is positioned between two thin pieces to form a close contact sheath. In one embodiment the high temperature energy source modified to output low to moderate temperatures is a nanolaminate multilayer foil of reactive materials that produces a heating level of less than 200.degree. C.

  4. [Study on lead absorption in pumpkin by atomic absorption spectrophotometry].

    Science.gov (United States)

    Li, Zhen-Xia; Sun, Yong-Dong; Chen, Bi-Hua; Li, Xin-Zheng

    2008-07-01

    A study was carried out on the characteristic of lead absorption in pumpkin via atomic absorption spectrophotometer. The results showed that lead absorption amount in pumpkin increased with time, but the absorption rate decreased with time; And the lead absorption amount reached the peak in pH 7. Lead and cadmium have similar characteristic of absorption in pumpkin.

  5. Correlation between some parameters of lead absorption and lead intoxication

    Science.gov (United States)

    Waldron, H. A.

    1971-01-01

    Waldron, H. A. (1971).Brit. J. industr. Med.,28, 195-199. Correlation between some parameters of lead absorption and lead intoxication. Use has been made of data collected over a number of years from workers exposed to a lead hazard in a motor-car factory. The correlations between various parameters of lead absorption and lead intoxication were computed, including blood and urine lead concentrations, urinary coproporphyrin, ALA and PBG concentrations, and haemoglobin concentration. In all, 15 correlation coefficients were calculated, of which only six showed a statistically significant result (i.e., Plead and urine lead (r = 0·38, Plead and coproporphyrin (r = 0·42, Plead and ALA (r = 0·43, Plead and PBG (r = 0·19, P<0·05). PMID:5572689

  6. Rapidity evolution of gluon TMD from low to moderate x

    International Nuclear Information System (INIS)

    Balitsky, I.

    2016-01-01

    I discuss how the rapidity evolution of gluon transverse momentum dependent distribution (TMD) changes from nonlinear evolution at small x << 1 to linear evolution at moderate x ∼ 1. I have described the rapidity evolution of gluon TMD in the whole range of Bjorken x B and the whole range of transverse momentum. It should be emphasized that with our definition of rapidity cutoff the leading-order matrix elements of TMD operators are UV-finite so the rapidity evolution is the only evolution and it describes all the dynamics of gluon TMDs in the leading-log approximation

  7. Low to moderate alcohol intake during pregnancy and risk of psychomotor deficits

    DEFF Research Database (Denmark)

    Bay, Bjørn; Støvring, Henrik; Wimberley, Theresa

    2012-01-01

    Background: To examine the effects of low to moderate alcohol consumption during pregnancy on child motor function at age 5. Methods: A prospective follow-up study of 685 women and their children sampled from the Danish National Birth Cohort based on maternal alcohol consumption during pregnancy...... reporting low to moderate levels of average alcohol consumption during pregnancy and children of mothers who abstained. Conclusions: In this study, we found no systematic association between low to moderate maternal alcohol intake during pregnancy and child motor function at age 5....

  8. EVALUATION OF ROTARY KILN INCINERATOR OPERATION AT LOW TO MODERATE TEMPERATURE CONDITIONS VOLUME 1. TECHNICAL RESULTS

    Science.gov (United States)

    A test program was performed at the Environmental Protection Agency Incineration Research Facility to study the effectiveness of incineration at low-to-moderate temperatures in decontaminating soils containing organic compounds with different volatilities (boiling points). The da...

  9. Iron, lead, and cobalt absorption: similarities and dissimilarities

    International Nuclear Information System (INIS)

    Barton, J.C.; Conrad, M.E.; Holland, R.

    1981-01-01

    Using isolated intestinal segments in rats, the absorption of iron, lead, and cobalt was increased in iron deficiency and decreased in iron loading. Similarly, the absorption of these metals was decreased in transfusional erythocytosis, after intravenous iron injection and after parenteral endotoxin injection. Acute bleeding or abbreviated intervals of dietary iron deprivation resulted in increased iron absorption from isolated intestinal segments and in intact animals, while the absorption of lead and cobalt was unaffected. These results suggest that the specificity of the mucosal metal absorptive mechanism is either selectively enhanced for iron absorption by phlebotomy or brief periods of dietary iron deprivation, or that two or more mucosal pathways for iron absorption may exist

  10. Gas absorption and discharge behaviors of lead-lithium

    International Nuclear Information System (INIS)

    Sakabe, Toshiro; Yokomine, Takehiko; Kunugi, Tomoaki; Kawara, Zensaku; Ueki, Yoshitaka; Tanaka, Teruya

    2014-01-01

    Highlights: • The absorption of argon in the lead-lithium is comparable with that of helium even at the solid state. • For the molten state of lead-lithium, the absorption of argon could be larger than that of helium. • It is observed that the argon tends to desorb when the phase change of lead-lithium occurs. • It is observed from the TPD-MS analysis that the argon tends to desorb when the phase change of lead-lithium occurs. - Abstract: The absorption of rare gas in the lead-lithium has been quite low and the gas is used as a cover-gas to control the environment of experiment. In our previous thermo-fluid experiment by using lithium-lead, it was found the cover gas pressure enclosed in the very leak tight container of lithium-lead was decreased with time, that is, the gas-absorption of the solid lithium-lead occurred at room temperature under atmospheric pressure. The variation of pressure exceeded the retention of argon in lead-lithium which is expected by the published data. Therefore, we aim to confirm those phenomena under well-controlled experimental condition by using argon, nitrogen and helium. According to the results of gas exposure tests, the absorption of argon in the lead-lithium is comparable with that of helium even at the solid state. For the molten state of lead-lithium, the absorption of argon could be larger than that of helium. It is also observed from the TPD-MS analysis that the argon tends to desorb when the phase change of lead-lithium occurs. If the retention of argon in the lead-lithium cannot be ignored, the problem of Ar-41 activity should be taken into consideration as well as the problem of argon bubble in the lead-lithium

  11. Determination of Lead in Blood by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramér, Kim

    1968-01-01

    Lead in blood was determined by atomic absorption spectrophotometry, using a wet ashing procedure and a procedure in which the proteins were precipitated with trichloroacetic acid. In both methods the lead was extracted into isobutylmethylketone before measurement, using ammonium pyrrolidine dithiocarbamate as chelator. The simpler precipitation procedure was shown to give results identical with those obtained with the ashing technique. In addition, blood specimens were examined by the precipitation method and by spectral analysis, which method includes wet ashing of the samples, with good agreement. All analyses were done on blood samples from `normal' persons or from lead-exposed workers, and no additions of inorganic lead were made. The relatively simple protein precipitation technique gave accurate results and is suitable for the large-scale control of lead-exposed workers. PMID:5663425

  12. Determination of Lead in Urine by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramé, Kim

    1968-01-01

    A method for the determination of lead in urine by means of atomic absorption spectrophotometry (AAS) is described. A combination of wet ashing and extraction with ammonium pyrrolidine dithiocarbamate into isobutylmethylketone was used. The sensitivity was about 0·02 μg./ml. for 1% absorption, and the detection limit was about 0·02 μg./ml. with an instrumental setting convenient for routine analyses of urines. Using the scale expansion technique, the detection limit was below 0·01 μg./ml., but it was found easier to determine urinary lead concentrations below 0·05 μg./ml. by concentrating the lead in the organic solvent by increasing the volume of urine or decreasing that of the solvent. The method was applied to fresh urines, stored urines, and to urines, obtained during treatment with chelating agents, of patients with lead poisoning. Urines with added inorganic lead were not used. The results agreed well with those obtained with a colorimetric dithizone extraction method (r = 0·989). The AAS method is somewhat more simple and allows the determination of smaller lead concentrations. PMID:5647975

  13. Determination of lead in mother's milk by atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Bandarchian, F.; Assadian, F

    2002-01-01

    With due attention to increasing air pollution specially the lead amount that is generated from gasoline burning in automobiles, it seems that it is necessary to control the amount of it continuously. Because Pb has an easy absorbability to body and also damages the nervous system. For this reason determination of it in mother's milk has a special importance. In this research, the milks of 15 mothers twice a day were examined and the concentration of Pb were determined by atomic absorption spectroscopy. In accordance the international organization, the permissible amount in body is 0.05 ppm. Fortunately, the obtained data was less than of it and it showed the absorbance of lead by babies is insignificant

  14. Efficacy of low to moderate doses of oxcarbazepine in adult patients with newly diagnosed partial epilepsy.

    Science.gov (United States)

    Zou, Xue-Mei; Chen, Jia-Ni; An, Dong-Mei; Hao, Nan-Ya; Hong, Zhen; Hao, Xiao-Ting; Rao, Ping; Zhou, Dong

    2015-07-01

    The objective of this study was to explore the efficacy of low dose of oxcarbazepine (OXC) in adult patients with newly diagnosed partial epilepsy in an actual clinical setting. The associated factors influencing the poor control of seizures were also evaluated. The epilepsy database (2010-2014) from the Epilepsy Clinic of West China Hospital was retrospectively reviewed. A total of 102 adult patients with newly diagnosed, previously untreated partial epilepsy initially treated with OXC were included, and divided into good response group (64) and poor response group (38) according to whether they were seizure-free for at least 12 months. There were 27 (26.5%) patients becoming seizure-free with OXC 600 mg/day monotherapy. The remaining 75 patients had doses of either increasing OXC to 900 mg/day (n = 59) or the addition of another antiepileptic drug (AED) (n = 16), with another 20 (19.6%) and six (5.9%) patients becoming seizure-free, respectively (P = 0.788). In addition, two (2.0%) and nine (8.8%) patients became seizure-free with OXC > 900 mg/day monotherapy and OXC ≥ 900 mg/day combination therapy, respectively. Multivariate binary logistic regression analysis revealed that the time from onset of epilepsy to treatment initiation is significantly associated with seizure control (P = 0.02). Our results indicated that OXC at low to moderate doses is effective for the treatment of Chinese adult patients with newly diagnosed, previously untreated partial epilepsy, and a longer time interval from the onset of epilepsy to the start of treatment significantly predicts poor seizure control. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  15. Acute Exposure to Low-to-Moderate Carbon Dioxide Levels and Submariner Decision Making.

    Science.gov (United States)

    Rodeheffer, Christopher D; Chabal, Sarah; Clarke, John M; Fothergill, David M

    2018-06-01

    Submarines routinely operate with higher levels of ambient carbon dioxide (CO2) (i.e., 2000 - 5000 ppm) than what is typically considered normal (i.e., 400 - 600 ppm). Although significant cognitive impairments are rarely reported at these elevated CO2 levels, recent studies using the Strategic Management Simulation (SMS) test have found impairments in decision-making performance during acute CO2 exposure at levels as low as 1000 ppm. This is a potential concern for submarine operations, as personnel regularly make mission-critical decisions that affect the safety and efficiency of the vessel and its crew while exposed to similar levels of CO2. The objective of this study was to determine if submariner decision-making performance is impacted by acute exposure to levels of CO2 routinely present in the submarine atmosphere during sea patrols. Using a subject-blinded balanced design, 36 submarine-qualified sailors were randomly assigned to receive 1 of 3 CO2 exposure conditions (600, 2500, or 15,000 ppm). After a 45-min atmospheric acclimation period, participants completed an 80-min computer-administered SMS test as a measure of decision making. There were no significant differences for any of the nine SMS measures of decision making between the CO2 exposure conditions. In contrast to recent research demonstrating cognitive deficits on the SMS test in students and professional-grade office workers, we were unable to replicate this effect in a submariner population-even with acute CO2 exposures more than an order of magnitude greater than those used in previous studies that demonstrated such effects.Rodeheffer CD, Chabal S, Clarke JM, Fothergill DM. Acute exposure to low-to-moderate carbon dioxide levels and submariner decision making. Aerosp Med Hum Perform. 2018; 89(6):520-525.

  16. The effects of low to moderate prenatal alcohol exposure in early pregnancy on IQ in 5-year-old children

    DEFF Research Database (Denmark)

    Eriksen, H-L Falgreen; Mortensen, Erik Lykke; Kilburn, Tina R.

    2012-01-01

    Please cite this paper as: Falgreen Eriksen H, Mortensen E, Kilburn T, Underbjerg M, Bertrand J, Støvring H, Wimberley T, Grove J, Kesmodel U. The effects of low to moderate prenatal alcohol exposure in early pregnancy on IQ in 5-year-old children. BJOG 2012;119:1191-1200. Objective To examine...... the effects of low to moderate maternal alcohol consumption during early pregnancy on children's intelligence (IQ) at age 5 years. Design Prospective follow-up study. Setting Neuropsychological testing in four Danish cities 2003-2008. Population A cohort of 1628 women and their children sampled from...... the Danish National Birth Cohort. Methods Participants were sampled based on maternal alcohol consumption during pregnancy. At 5 years of age, children were tested with the Wechsler Preschool and Primary Scale of Intelligence-Revised (WPPSI-R). Parental education, maternal IQ, maternal smoking in pregnancy...

  17. Factors affecting the absorption and excretion of lead in the rat

    International Nuclear Information System (INIS)

    Conrad, M.E.; Barton, J.C.

    1978-01-01

    A reliable method for studying lead absorption and excretion in rats is described. Lead absorption occurs primarily in the duodenum where lead enters the epithelial mucosal cells. There is a relative mucosal block for lead with increasing intraluminal doses. Certain substances which bind lead and increase its solubility enhance its absorption. Iron, zinc, and calcium decrease the absorption of lead without affecting its solubility, probably by competing for shared absorptive receptors in the intestinal mucosa. The total body burden of lead does not affect lead absorption. Thus, lead does not have a feedback mechanism which limits absorption. Lead absorption is increased during rapid periods of growth and in iron-deficient animals. It is diminished with starvation and in iron-overloaded animals. The excretion and kinetics of tracer doses of radiolead were quantified. Erythrocytes seem to serve an important role in transport. Excretion occurs in urine and stool. Bile is an important route of excretion in the gut. Although most of a tracer dose is rapidly excreted, the excretory process is limited permitting lead accumulation primarily in bone

  18. Rooftop Solar Technical Potential for Low-to-Moderate Income Households in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Sigrin, Benjamin O [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Mooney, Meghan E [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-04-17

    This report presents a first-of-kind assessment of the technical potential of rooftop solar for low and moderate-income households, as well as providing insight on the distribution of solar potential by tenure, income, and other building characteristics. We find that a substantial fraction of the national rooftop solar potential is located on LMI buildings and, for all incomes, a substantial fraction on multi-family and renter-occupied buildings. We also find that rooftop solar can significantly contribute to long-term penetration targets established by the U.S. DOE, though to do so requires deployment on multi-family and renter-occupied buildings. Traditional deployment models have insufficiently enabled access to solar for these income groups and building types. Without innovation either in regulatory, market, or policy factors, a large fraction of the U.S. potential is unlikely to be addressed, as well as leading to inequalities in solar access. Ironically, potential electric bill savings from rooftop solar would have the greatest material impact on the lives of low-income households as compared to their high-income counterparts.

  19. Simultaneous Atomic Absorption Spectrometry for Cadmium and Lead Determination in Wastewater: A Laboratory Exercise

    Science.gov (United States)

    Correia, Paulo R. M.; Oliveira, Pedro V.

    2004-01-01

    The simultaneous determination of cadmium and lead by multi-element atomic absorption spectrometry with electrochemical atomization is proposed by employing a problem-based approach. The reports indicate that the students assimilated the principles of the simultaneous atomic absorption spectrometry (SIMAAS), the role of the chemical modifier, the…

  20. Influence of dietary minerals and fat on the absorption of lead. [Rats

    Energy Technology Data Exchange (ETDEWEB)

    Barltrop, D.; Khoo, H.E.

    1976-01-01

    The nutritional factors influencing the absorption of lead from the gut were studied using both intact animals and ligated gut loop preparation. Short-term feeding studies were made in groups of six rats using diets of constant lead content (0.075%) but in which the nutritional components were varied sequentially. Dietary lead was labelled with /sup 203/Pb. Absorption was determined in the carcass and individual organs by means of a small-animal whole-body counter. The results showed that absorption was enhanced to twenty-times control value by diets deficient in minerals and seven-fold by diets of high fat content. Conversely, high mineral diets were shown to result in a two-fold reduction in lead absorption. The interaction of lead with individual dietary components was further studied under controlled conditions using ligated gut loop preparations. Using this technique the relative roles of luminal interaction and tissue response for lead absorption were explored and the kinetics of lead absorption determined.

  1. Lead transfer in maternal milk, and the absorption, retention, distribution and excretion of lead in suckling mice

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Charles Arthur [Univ. of Rochester, NY (United States). Dept. of Radiation Biology and Biophysics

    1980-01-01

    Suckling mice were found to absorb and retain a greater fraction of an oral lead dose than did adult mice. Pinocytotic activity and lead uptake (in vivo) were found to be greatest in the distal small intestinal tissue. Cortisone pretreatment results in precocious cessation of pinocytotic activity in the intestine of suckling mice. Cortisone pretreatment of adult mice had no effect on whole body lead retention or intestinal tissue content of lead following an oral dose. The data indicate that the distal small intestine is the site of active pinocytosis of lead, and that pinocytosis is the major mechanism involved in lead absorption in suckling mice. Developmental differences were also observed in the percentage of lead retained in the whole body. Both groups exhibited dose-independent lead retention, indicating a first-order absorption process for each age group. Lead distribution and elimination from organs also differed between suckling and adult mice. Developmental differences were observed in organ lead concentration for kidneys and brain following oral doses. Relative distribution of lead to the brains of suckling mice were greater than to adult brains. Whole body and bone lead elimination rates were reduced in suckling compared to adult mice. Brain lead elimination rates did not differ in suckling and adult mice. A lactating mouse model was developed to study lead transfer to suckling offspring. Lead was transferred in milk to suckling offspring from mothers which had previously ingested lead in the drinking water. Relative lead transfer to suckled offspring during lactation greatly exceeded transfer to fetuses during gestation. Lactation resulted in an increased rate of maternal lead elimination. Lead concentration in milk exceeded plasma concentration by a factor of approximately 25. (ERB)

  2. Oxidative stress, telomere shortening, and DNA methylation in relation to low-to-moderate occupational exposure to welding fumes.

    Science.gov (United States)

    Li, Huiqi; Hedmer, Maria; Wojdacz, Tomasz; Hossain, Mohammad Bakhtiar; Lindh, Christian H; Tinnerberg, Håkan; Albin, Maria; Broberg, Karin

    2015-10-01

    Evidence suggests that exposure to welding fumes is a risk factor for lung cancer. We examined relationships between low-to-moderate occupational exposure to particles from welding fumes and cancer-related biomarkers for oxidative stress, changes in telomere length, and alterations in DNA methylation. We enrolled 101 welders and 127 controls (all currently nonsmoking men) from southern Sweden. We performed personal sampling of respirable dust and measured 8-oxodG concentrations in urine using a simplified liquid chromatography tandem mass spectrometry method. Telomere length in peripheral blood was measured by quantitative polymerase chain reaction. Methylation status of 10 tumor suppressor genes was determined by methylation-sensitive high-resolution melting analysis. All analyses were adjusted for age, body mass index, previous smoking, passive smoking, current residence, and wood burning stove/boiler at home. Welders were exposed to respirable dust at 1.2 mg/m(3) (standard deviation, 3.3 mg/m(3); range, 0.1-19.3), whereas control exposures did not exceed 0.1 mg/m(3) (P < 0.001). Welders and controls did not differ in 8-oxodG levels (β = 1.2, P = 0.17) or relative telomere length (β = -0.053, P = 0.083) in adjusted models. Welders showed higher probability of adenomatous polyposis coli (APC) methylation in the unadjusted model (odds ratio = 14, P = 0.014), but this was not significant in the fully adjusted model (P = 0.052). Every working year as a welder was associated with 0.0066 units shorter telomeres (95% confidence interval -0.013 to -0.00053, P = 0.033). Although there were no clear associations between concentrations of respirable dust and the biomarkers, there were modest signs of associations between oxidative stress, telomere alterations, DNA methylation, and occupational exposure to low-to-moderate levels of particles. © 2015 Wiley Periodicals, Inc.

  3. CLINICAL STUDY TO EVALUATE THE VISUAL OUTCOME AND PATIENT COMFORT IN LASIK AND PHOTOREFRACTIVE KERATECTOMY IN LOW-TO-MODERATE MYOPIC ASTIGMATISM PATIENTS

    OpenAIRE

    Ashok Kumar P; Ananda Babu M; Radha Priyadharshini R; Jeevitha A

    2017-01-01

    BACKGROUND To evaluate visual outcomes following LASIK and Photorefractive Keratectomy (PRK) in low-to-moderate myopia and/or myopic astigmatism in age and refractive error matched eyes. MATERIALS AND METHODS Of a total 30 patients aged ≥21 years, 20 (40 eyes) underwent LASIK and 10 (20 eyes) underwent PRK for low-to-moderate myopia or myopic astigmatism. LASIK was performed with the Alcon wave light 500 and PRK with the alcohol application for epithelial removal. All abl...

  4. Circuit Board Analysis for Lead by Atomic Absorption Spectroscopy in a Course for Nonscience Majors

    Science.gov (United States)

    Weidenhammer, Jeffrey D.

    2007-01-01

    A circuit board analysis of the atomic absorption spectroscopy, which is used to measure lead content in a course for nonscience majors, is being presented. The experiment can also be used to explain the potential environmental hazards of unsafe disposal of various used electronic equipments.

  5. Determination of lead and cadmium in urine by electrothermal atomization atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Vasil'eva, L.A.; Grinshtejn, I.L.; Gucher, Sh.; Izgi, B.

    2008-01-01

    The applicability of a DETATA sorbent to the preconcentration of lead and cadmium followed by the determination of these elements in urine using atomic absorption spectrometry with electrothermal atomization was demonstrated. After preconcentration by a factor of 10, the limits of detection were 0.01 and 0.2 μg/l for cadmium and lead, respectively. The accuracy of the results was supported by the analysis of Seronorm TM Trace Elements Urine Batch no.101021 [ru

  6. Influence of 2,3-dimercaptosuccinic acid on gastrointestinal lead absorption and whole-body lead retention

    International Nuclear Information System (INIS)

    Kapoor, S.C.; Wielopolski, L.; Graziano, J.H.; LoIacono, N.J.

    1989-01-01

    2,3-Dimercaptosuccinic acid (DMSA) is a new orally active heavy metal chelator for the treatment of childhood Pb intoxication on an outpatient basis. The influence of DMSA, as well as other chelating agents, on gastrointestinal 203Pb absorption and whole-body 203 Pb retention was examined. Groups of Sprague-Dawley rats (230-260 g) were gavaged with a solution containing approximately 25 mg/kg Pb [as Pb(NO 3 )2] plus 15 microCi 203 Pb. Some groups were then immediately given 0.11 mmol/kg of either DMSA, CaNa2EDTA, D-penicillamine, or BAL by oral gavage, while other groups received the same drugs by ip injection. Control groups received solutions of the drug vehicles po or ip. Whole-body Pb retention and gastrointestinal Pb absorption (whole body retention + urinary Pb excretion) were significantly decreased in rats that received DMSA po. This finding implies that the use of DMSA to treat childhood lead intoxication on an outpatient basis is not associated with a risk for increased Pb absorption

  7. Monitoring of lead levels in spices and food colors using atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Rahman, S.; Khalid, N.; Ahmad, S.

    2001-01-01

    The concentration of lead has been monitored in various commercial brands of spices and food colours using atomic absorption spectrometry after digestion in a mixture of nitric acid and perchloric acid. The reliability of the procedure used was checked by analyzing the standard reference materials namely wheat flour (NBS-1567) and rice flour (NBS-1568), for their lead contents. The determined concentration of lead ranged from 5.60 to 10.12 mg g-1 in food spices and from 1.62 to 1.81 mg g-1 in food colours. The study revealed that the piper nigrum contains higher lead contents as compared to capsicum. The effect of processing/milling on the concentration of lead in spices was also studied and discussed. The daily intake of lead by adults through spices and food colours was estimated and was found to be within the recommended WHO tolerance levels. (author)

  8. Does lead use the intestinal absorptive pathways of iron? Impact of iron status on murine 210Pb and 59Fe absorption in duodenum and ileum in vivo

    International Nuclear Information System (INIS)

    Elsenhans, Bernd; Janser, Heinz; Windisch, Wilhelm; Schuemann, Klaus

    2011-01-01

    Highlights: → Absorption of 210 Pb increases much less than that of 59 Fe in murine duodena. → 210 Pb-absorption is almost equally high in murine duodenal and ileal segments. → 59 Fe absorption is much lower in ileal than in duodenal segments. → There must be an additional DMT1-independet pathway for intestinal Pb absorption. -- Abstract: Background: Human isotope studies and epidemiological trials are controversial as to whether lead absorption shares the absorptive pathways of iron and whether body lead content can be reduced by iron supplementation. Aim: To compare the impact of iron-deficiency on 59 Fe- and 210 Pb-absorption rates in duodenal and ileal segments. Methods: 59 Fe- and 210 Pb-absorption was determined in ligated duodenal and ileal segments from juvenile and adult iron-deficient and iron-adequate C57Bl6 wild-type mice (n = 6) in vivo at luminal concentrations corresponding to human exposure (Fe: 1 and 100 μmol/L; Pb: 1 μmol/L). Results and discussion: 59 Fe-absorption increased 10-15-fold in iron-deficient duodena from adult and adolescent mice. Ileal 59 Fe-absorption was 4-6 times lower than in iron-adequate duodena showing no adaptation to iron-deficiency. This in accordance to expectation as the divalent metal transport 1 (DMT1) shows low ileal expression levels. Juvenile 59 Fe-absorption was about twice as high as in adult mice. In contrast, duodenal 210 Pb-absorption was increased only 1.5-1.8-fold in iron-deficiency in juvenile and adult mice and, again in contrast to 59 Fe, ileal 210 Pb-absorption was as high as in iron-adequate duodena. Conclusions: The findings suggest a DMT1-independent pathway to mediate lead absorption along the entire small intestine in addition to DMT1-mediated duodenal uptake. Ileal lead absorption appears substantial, due the much longer residence of ingesta in the distal small intestine. Differences in lead-solubility and -binding to luminal ligands can, thus, explain the conflicting findings regarding the

  9. Long-term effectiveness and cost-effectiveness of high versus low-to-moderate intensity resistance and endurance exercise interventions among cancer survivors

    NARCIS (Netherlands)

    Kampshoff, C. S.; van Dongen, J. M.; van Mechelen, W.; Schep, G.; Vreugdenhil, A.; Twisk, J. W.R.; Bosmans, J. E.; Brug, J.; Chinapaw, M. J.M.; Buffart, Laurien M.

    Purpose: This study aimed to evaluate the long-term effectiveness and cost-effectiveness of high intensity (HI) versus low-to-moderate intensity (LMI) exercise on physical fitness, fatigue, and health-related quality of life (HRQoL) in cancer survivors. Methods: Two hundred seventy-seven cancer

  10. Low to moderate alcohol consumption on serum vitamin D and other indicators of bone health in postmenopausal women in a controlled feeding study

    Science.gov (United States)

    Heavy alcohol drinking adversely affects vitamin D status and bone health. However, data from randomized, placebo-controlled trials (RCTs) on the effects of low to moderate alcohol consumption on vitamin D status and bone health in humans is unavailable. The objective of this cross-over RCT was to e...

  11. Variations in Hematologic Responses to Increased Lead Absorption in Young Children

    Science.gov (United States)

    Chisolm, J. Julian; Mellits, E. David; Keil, Julian E.; Barrett, Maureen B.

    1974-01-01

    In the study of human populations, much emphasis is placed on the concentration of lead in whole peripheral blood. There is a considerable body of evidence which indicates that this measurement reflects recent and current assimilation of lead. While broad ranges in blood lead concentration have been associated with differing risks of toxicity for groups, it is not a precise index of adverse effect per se, even at elevated levels. Within the red blood cell itself there is not a close association between the concentration of lead and such adverse metabolic effects as the increased loss of potassium caused by lead. Above the apparent “threshold zone” of approximately 30–50 μg Pb/100 ml whole blood, equivalent metabolic effects on heme synthesis may be seen over an interval of at least 20 μg Pb/100 ml whole blood. This variation will be examined with particular reference to the interrelationship between the concentrations of lead and protoporphyrin in peripheral blood. The data indicate that limitations in both precision and accuracy of measurement account for a relatively small fraction of the observed variations. Together with other experimental and clinical information, they suggest that concurrent dietary deficiency of iron may be one of the important modifying factors in the responses of subjects with increased lead absorption. It is suggested that suspected adverse effects upon the various organ systems associated with increased lead absorption be measured directly and that the CaEDTA mobilization test for lead should be more fully explored as a measure of the “metabolically active” fraction of the total body lead burden. PMID:4831151

  12. The determination of aluminum, copper, iron, and lead in glycol formulations by atomic absorption spectroscopy

    Science.gov (United States)

    1977-01-01

    Initial screening tests and the results obtained in developing procedures to determine Al, Cu, Fe, and Pb in glycol formulations are described. Atomic absorption completion was selected for Cu, Fe and Pb, and after comparison with emission spectroscopy, was selected for Al also. Before completion, carbon, iron, and lead are extracted with diethyl dithio carbamate (DDC) into methyl isobutyl ketone (MIBK). Aluminum was also extracted into MIBK using 8-hydroxyquinoline as a chelating agent. As little as 0.02 mg/l carbon and 0.06 mg/l lead or iron may be determined in glycol formulations. As little as 0.3 mg/l aluminum may be determined.

  13. Exciton-Dominated Core-Level Absorption Spectra of Hybrid Organic–Inorganic Lead Halide Perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Vorwerk, Christian [Institut für Physik and IRIS Adlershof, Humboldt-Universität zu Berlin, European Theoretical Spectroscopy; Hartmann, Claudia [Renewable Energy, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 14109 Berlin, Germany; Cocchi, Caterina [Institut für Physik and IRIS Adlershof, Humboldt-Universität zu Berlin, European Theoretical Spectroscopy; Sadoughi, Golnaz [Clarendon Laboratory, Department of Physics, University of Oxford, Oxford OX1 3PU, United Kingdom; Habisreutinger, Severin N. [Clarendon Laboratory, Department of Physics, University of Oxford, Oxford OX1 3PU, United Kingdom; Chemistry and Nanoscience Center, National Renewable Energy Laboratory (NREL), Golden, Colorado, United States; Félix, Roberto [Renewable Energy, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 14109 Berlin, Germany; Wilks, Regan G. [Renewable Energy, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 14109 Berlin, Germany; Energy Materials In-Situ Laboratory Berlin (EMIL), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 12489 Berlin, Germany; Snaith, Henry J. [Clarendon Laboratory, Department of Physics, University of Oxford, Oxford OX1 3PU, United Kingdom; Bär, Marcus [Renewable Energy, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 14109 Berlin, Germany; Energy Materials In-Situ Laboratory Berlin (EMIL), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 12489 Berlin, Germany; Draxl, Claudia [Institut für Physik and IRIS Adlershof, Humboldt-Universität zu Berlin, European Theoretical Spectroscopy

    2018-03-23

    In a combined theoretical and experimental work, we investigate X-ray absorption near-edge structure spectroscopy of the I L3 and the Pb M5 edges of the methylammonium lead iodide (MAPbI3) hybrid inorganic-organic perovskite and its binary phase PbI2. The absorption onsets are dominated by bound excitons with sizable binding energies of a few hundred millielectronvolts and pronounced anisotropy. The spectra of both materials exhibit remarkable similarities, suggesting that the fingerprints of core excitations in MAPbI3 are essentially given by its inorganic component, with negligible influence from the organic groups. The theoretical analysis complementing experimental observations provides the conceptual insights required for a full characterization of this complex material.

  14. The effects of low to moderate alcohol consumption and binge drinking in early pregnancy on selective and sustained attention in 5-year-old children

    DEFF Research Database (Denmark)

    Underbjerg, Mette; Kesmodel, Ulrik S.; Landrø, Nils Inge

    2012-01-01

    Please cite this paper as: Underbjerg M, Kesmodel U, Landrø N, Bakketeig L, Grove J, Wimberley T, Kilburn T, Svaerke C, Thorsen P, Mortensen E. The effects of low to moderate alcohol consumption and binge drinking in early pregnancy on selective and sustained attention in 5-year-old children. BJOG...... 2012;119:1211-1221. Objective  The aim was to examine the effects of low to moderate maternal alcohol consumption and binge drinking in early pregnancy on children's attention at 5 years of age. Design  Prospective follow-up study. Setting  Neuropsychological testing in four Danish cities 2003......-2008. Population  A cohort of 1628 women and their children sampled from the Danish National Birth Cohort. Methods  Participants were sampled based on maternal alcohol consumption during pregnancy. At 5 years of age, the children were tested with the recently developed Test of Everyday Attention for Children...

  15. The effects of low to moderate alcohol consumption and binge drinking in early pregnancy on executive function in 5-year-old children

    DEFF Research Database (Denmark)

    Skogerbø, A; Kesmodel, Ulrik S.; Wimberley, Theresa

    2012-01-01

    Please cite this paper as: SkogerbøÅ, Kesmodel U, Wimberley T, Støvring H, Bertrand J, Landrø N, Mortensen E. The effects of low to moderate alcohol consumption and binge drinking in early pregnancy on executive function in 5-year-old children. BJOG 2012;119:1201-1210. Objective  To examine...... the effects of low to moderate maternal alcohol consumption and binge drinking in early pregnancy on children's executive functions at the age of 5 years. Design  Follow-up study. Setting  Neuropsychological testing in four Danish cities 2003-2008. Population  A cohort of 1628 women and their children sampled...... from the Danish National Birth Cohort. Methods  Participants were sampled based on maternal alcohol drinking patterns during early pregnancy. When the children were 5 years old, the parent and teacher forms of the Behaviour Rating Inventory of Executive Function (BRIEF) were completed by the mothers...

  16. Clinical Perspective on Antihypertensive Drug Treatment in Adults With Grade 1 Hypertension and Low-to-Moderate Cardiovascular Risk

    DEFF Research Database (Denmark)

    Morales Salinas, Alberto; Coca, Antonio; Olsen, Michael H.

    2017-01-01

    Hypertension is a leading risk factor for disease burden globally. An unresolved question is whether grade 1 hypertension (140-159/90-99. mm. Hg) with low (cardiovascular mortality <1% at 10 years) to moderate (cardiovascular mortality ≥1% and <5% at 10 years) absolute total cardiovascular risk (...

  17. Efficacy and safety of transcatheter aortic valve replacement in aortic stenosis patients at low to moderate surgical risk: a comprehensive meta-analysis

    OpenAIRE

    Elmaraezy, Ahmed; Ismail, Ammar; Abushouk, Abdelrahman Ibrahim; Eltoomy, Moutaz; Saad, Soha; Negida, Ahmed; Abdelaty, Osama Mahmoud; Abdallah, Ahmed Ramadan; Aboelfotoh, Ahmed Magdy; Hassan, Hossam Mahmoud; Elmaraezy, Aya Gamal; Morsi, Mahmoud; Althaher, Farah; Althaher, Moath; AlSafadi, Ammar M.

    2017-01-01

    Background Recently, transcatheter aortic valve replacement (TAVR) has become the procedure of choice in high surgical risk patients with aortic stenosis (AS). However, its value is still debated in operable AS cases. We performed this meta-analysis to compare the safety and efficacy of TAVR to surgical aortic valve replacement (SAVR) in low-to-moderate surgical risk patients with AS. Methods A systematic search of five authentic databases retrieved 11 eligible studies (20,056 patients). Rele...

  18. Lead determination in uranium mineralization soils by atomic absorption spectrometry with graphite oven

    International Nuclear Information System (INIS)

    Teixeira, Gleber Tacio

    2001-01-01

    The contamination of soils by lead has a great environmental importance due to its toxicity to vegetables, animals and humans. In general, the mobility of the lead is small due to its low solubility and strong adsorption in the soil. However, its solubility can be altered by several conditions (pH, redox potential and ionic stronger). Consequently, lead can migrate through the soil and can contaminate superficial and underground waters. The objective of this work was to determine the concentration of total lead in soil samples with uranium mineralization, in an area at Ipora/GO, having been evaluated as economically insuitable the extraction of that mineral. The radiogenic lead appears as a product of natural radioactive elements decay. In the decay series of uranium-238 we found the isotope lead-214 (half-life of 26,8 min), lead-210 (half-life of 22,3 min), and lead-206 that is stable. The sampling was done in profiles around north, south, east and west directions, starting from a reference point (FT), chosen by presenting the largest radiation of that place (4800 cps). A mass of 1 Kg of superficial soil was collected to each 20 m, in each profile, until 150 m of FT. Approximately, 1 g of dry soil, fraction 2 mm, was digested with a mixture of acids HNO 3 /HClO 4 2:1 (v/v), and the resulting solution was analyzed by atomic absorption. An atomic absorption spectrometer was used with graphite furnace, with deuterium arc to background correction and pyrolytic coated tube. Phosphoric acid was used as chemical modifier. The obtained results, using the standard additions method, presented a decrease of the lead concentration, in all profiles, when the distance of FT was increased. It was also made a radiometric screening in each sampling point. The lead concentration variate from 115,1 μg.g -1 in FT, to less than 40 μg.g -1 at 150 m of distance of FT ( 3 ) 2 was used. The method was applied to a certified sample, showing a good agreement between certified and

  19. Determination of Lung-to-Blood Absorption Rates for Lead and Bismuth which are Appropriate for Radon Progeny

    International Nuclear Information System (INIS)

    Marsh, J.W.; Birchall, A.

    1999-01-01

    The ICRP Publication 66 Human Respiratory Tract Model (HRTM) treats clearance as a competitive process between absorption into blood and particle transport to the gastrointestinal tract and lymphatics. The ICRP recommends default absorption rates for lead and bismuth in ICRP Publication 71 but states that the values are not appropriate for short-lived radon progeny. This paper describes an evaluation of published data from volunteer experiments to estimate the absorption half-times of lead and bismuth that are appropriate for short-lived radon progeny. The absorption half-time for lead was determined to be 10±2 h, based on 212 Pb lung and blood retention data from several studies. The absorption half-time for bismuth was estimated to be about 13 h, based on 212 Bi urinary excretion data from one experiment and the ICRP biokinetic model for bismuth as a decay product of lead. (author)

  20. Determination of lead in whole blood: Comparison of the LeadCare blood lead testing system with zeeman longitudinal electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pineau, A.; Viallefont, A.; Fauconneau, B.; Rafael, M.; Guillard, O.

    2002-01-01

    This study compares the efficiency of blood lead level analysis by graphite furnace atomic absorption spectrometry (GFAAS) and the portable LeadCare Blood lead testing system (LCS). Recoveries of two added lead concentrations of 22 and 42 μg/dL ranged from 102.4 to 105.5% for LCS and from 96.3 to 97.2% for GFAAS. Measurement of a certified sample (Certified Danish Whole Blood) at a blood lead concentration of 26.2 μg/dL gave within- and between-run coefficients of variation which were both approximately 8% by LCS and 2% by GFAAS. Comparison of the tested method (LCS) versus GFAAS from analysis of 76 samples of blood lead collected from workers in different industrial sectors showed imperfect overall correlation (r = 0.95). The LCS is quite suitable for screening purposes, but requires the use of non-frozen blood collected less than 24 h before. Conservative threshold values should be applied when using the LCS for initial screening in the field. (orig.)

  1. Determination of tellurium in lead and lead alloy using flow injection-hydride generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Mesko, Marcia F.; Pozebon, Dirce; Flores, Erico M.M.; Dressler, Valderi L.

    2004-01-01

    A method based on flow injection-hydride generation atomic absorption spectrometry (FI-HG AAS) for the determination of trace amount of Te in lead and lead alloy is described. A flow injection system (FI) and related analytical parameters as well as Te determination and interference caused by Pb, Bi and Ag on Te were investigated. The Pb interference could be overcome by using a small sample volume, while the Bi interference could be overcome by thiourea. However, it was not possible to minimise the interference caused by Ag on Te. The optimised conditions for Te determination in the analysed samples were: 6 mol l -1 HCl as sample carrier solution, 0.75% (m/v) sodium tetrahydroborate as Te reductant, 40 μl of sample solution, and 200 ml min -1 Ar flow rate as carrier gas. The limit of quantification (LOQ) was 1.0 μg g -1 Te (using 250 mg of sample in 50 ml final solution), the limit of detection (LOD) was 2.5 μg l -1 and the relative standard deviation (RSD) was 6% for five consecutive measurements of sample solution. The standard addition calibration method was used. Relatively high sample throughput (ca. 45 sample runs can be performed in a working hour), reduced sample manipulation since matrix separation is not necessary, and minor waste generation are the main advantages of the proposed method for Te determination by FI-HG AAS

  2. Urban airborne lead: X-ray absorption spectroscopy establishes soil as dominant source.

    Directory of Open Access Journals (Sweden)

    Nicholas E Pingitore

    Full Text Available BACKGROUND: Despite the dramatic decrease in airborne lead over the past three decades, there are calls for regulatory limits on this potent pediatric neurotoxin lower even than the new (2008 US Environmental Protection Agency standard. To achieve further decreases in airborne lead, what sources would need to be decreased and what costs would ensue? Our aim was to identify and, if possible, quantify the major species (compounds of lead in recent ambient airborne particulate matter collected in El Paso, TX, USA. METHODOLOGY/PRINCIPAL FINDINGS: We used synchrotron-based XAFS (x-ray absorption fine structure to identify and quantify the major Pb species. XAFS provides molecular-level structural information about a specific element in a bulk sample. Pb-humate is the dominant form of lead in contemporary El Paso air. Pb-humate is a stable, sorbed complex produced exclusively in the humus fraction of Pb-contaminated soils; it also is the major lead species in El Paso soils. Thus such soil must be the dominant source, and its resuspension into the air, the transfer process, providing lead particles to the local air. CONCLUSIONS/SIGNIFICANCE: Current industrial and commercial activity apparently is not a major source of airborne lead in El Paso, and presumably other locales that have eliminated such traditional sources as leaded gasoline. Instead, local contaminated soil, legacy of earlier anthropogenic Pb releases, serves as a long-term reservoir that gradually leaks particulate lead to the atmosphere. Given the difficulty and expense of large-scale soil remediation or removal, fugitive soil likely constrains a lower limit for airborne lead levels in many urban settings.

  3. Urban airborne lead: X-ray absorption spectroscopy establishes soil as dominant source.

    Science.gov (United States)

    Pingitore, Nicholas E; Clague, Juan W; Amaya, Maria A; Maciejewska, Beata; Reynoso, Jesús J

    2009-01-01

    Despite the dramatic decrease in airborne lead over the past three decades, there are calls for regulatory limits on this potent pediatric neurotoxin lower even than the new (2008) US Environmental Protection Agency standard. To achieve further decreases in airborne lead, what sources would need to be decreased and what costs would ensue? Our aim was to identify and, if possible, quantify the major species (compounds) of lead in recent ambient airborne particulate matter collected in El Paso, TX, USA. We used synchrotron-based XAFS (x-ray absorption fine structure) to identify and quantify the major Pb species. XAFS provides molecular-level structural information about a specific element in a bulk sample. Pb-humate is the dominant form of lead in contemporary El Paso air. Pb-humate is a stable, sorbed complex produced exclusively in the humus fraction of Pb-contaminated soils; it also is the major lead species in El Paso soils. Thus such soil must be the dominant source, and its resuspension into the air, the transfer process, providing lead particles to the local air. Current industrial and commercial activity apparently is not a major source of airborne lead in El Paso, and presumably other locales that have eliminated such traditional sources as leaded gasoline. Instead, local contaminated soil, legacy of earlier anthropogenic Pb releases, serves as a long-term reservoir that gradually leaks particulate lead to the atmosphere. Given the difficulty and expense of large-scale soil remediation or removal, fugitive soil likely constrains a lower limit for airborne lead levels in many urban settings.

  4. Radiation trapping in atomic absorption spectroscopy at lead determination in different matricies

    International Nuclear Information System (INIS)

    El-Gohary, Z.

    2005-01-01

    The determination of lead by flame atomic absorption analysis in the presence of Sn and Fe atoms and different matrices such as OH and SO 3 was investigated with the objective of understanding the spectral interference processes at the analytical lines 283.31 nm for a wide range of concentration. The radiation trapping factor was interpreted and evaluated assuming Voigt distribution of the atomic and rotational lines in the flame. The radiation trapping factor was increased by increasing the number density (plasma of the absorbing medium is optically thick). In plasma, there is a certain point of equilibrium between the trapping and the escaping of radiation, which is relevant to 50% of absorption. The spectral background interference can cause a variation of the number density at equilibrium point as a result of the degree of overlap with the analytical line. The spectral background interference can be easily avoided by using another resonance absorption line for the analysis. The chemical modification of the matrix is applied to minimize the interference effect. Nitric acid, ammonium nitrate and magnesium nitrate are most commonly recommended as matrix modifiers

  5. Effects of iron deficiency on the absorption and distribution of lead and cadmium in rats

    International Nuclear Information System (INIS)

    Ragan, H.A.

    1977-01-01

    In order to evaluate the effects of iron deficiency on the absorption of pollutant metals, an iron-deficient diet was fed to young rats until their tissue-iron stores were depleted. Prior to the development of anemia, the iron-deficient rats and littermate controls were administered an intragastric gavage of lead-210 or cadmium-109 and were killed 48 hr later. The body burden of lead was approximately 6 times greater, and that of cadmium approximately 7 times greater, in iron-deficient rats than in the controls. No consistent effects were observed on concentrations of serum total lipids or serum proteins nor on protein electrophoretic patterns in rats with a deficit in iron stores

  6. Use of atomic absorption spectrometry in assessment of biomonitor plants for lead, cadmium and copper pollution.

    Science.gov (United States)

    Gokce, Kaya; Mehmet, Yaman

    2012-01-01

    Eleven plant species were collected from the vicinity of lead-battery plant in the city of Gaziantep, Turkey. Lead, cadmium and copper concentrations in the soil and leaves of plants were determined by atomic absorption spectrometry. Lead, Cd and Cu concentrations in the soil samples taken from battery area were found to be in the ranges of 304-602, 0.4-0.44 and 31-37 mg x kg(-1), respectively. Significantly increased lead concentration up to 2 750 mg x kg(-1) was found in the leaves of Eleagnus angustifolia L. plant. The lead concentrations in the other plant leaves taken from 50 m around battery factory followed the order Ailanthus altissima > Morus sp. > Juglans regia L. > Ficus carica L. > Cydonia oblonga Miller > Prunus x domestica L. The plants, Populus nigra L. , Eleagnus angustifolia L. and Salix sp. were found useful for Cd, and the plant, Eleagnus angusti folia L. for Pb, to be considered as potential biomonitor. Especially, leaves of trees and plants taken from the distance of 50 m from battery plant have relatively higher Pb concentrations. Therefore, people who and animals which live in this area and benefit from these soil and plants have vital risks.

  7. Comparison of two methods for blood lead analysis in cattle: graphite-furnace atomic absorption spectrometry and LeadCare(R) II system.

    Science.gov (United States)

    Bischoff, Karyn; Gaskill, Cynthia; Erb, Hollis N; Ebel, Joseph G; Hillebrandt, Joseph

    2010-09-01

    The current study compared the LeadCare(R) II test kit system with graphite-furnace atomic absorption spectrometry for blood lead (Pb) analysis in 56 cattle accidentally exposed to Pb in the field. Blood Pb concentrations were determined by LeadCare II within 4 hr of collection and after 72 hr of refrigeration. Blood Pb concentrations were determined by atomic absorption spectrometry, and samples that were coagulated (n = 12) were homogenized before analysis. There was strong rank correlation (R(2) = 0.96) between atomic absorption and LeadCare II (within 4 hr of collection), and a conversion formula was determined for values within the observed range (3-91 mcg/dl, although few had values >40 mcg/dl). Median and mean blood pb concentrations for atomic absorption were 7.7 and 15.9 mcg/dl, respectively; for LeadCare II, medians were 5.2 mcg/dl at 4 hr and 4.9 mcg/dl at 72 hr, and means were 12.4 and 11.7, respectively. LeadCare II results at 4 hr strongly correlated with 72 hr results (R(2) = 0.96), but results at 72 hr were lower (P atomic absorption. Although there have been several articles that compared LeadCare with other analytical techniques, all were for the original system, not LeadCare II. The present study indicated that LeadCare II results correlated well with atomic absorption over a wide range of blood Pb concentrations and that refrigerating samples for up to 72 hr before LeadCare II analysis was acceptable for clinical purposes.

  8. Atomic absorption spectrometric determination of copper, zinc, and lead in geological materials

    Science.gov (United States)

    Sanzolone, R.F.; Chao, T.T.

    1976-01-01

    An atomic absorption spectrometric method is described for the determination of copper, zinc, and lead in geological materials. The sample is digested with HF-HCl-H2O2; the final solution for analysis is in 10 % (v/v) HCl. Copper and zinc are determined directly by aspirating the solution into an air-acetylene flame. A separate aliquot of the solution is used for determination of lead; lead is extracted into TOPO-MIBK from the acidic solution in the presence of iodide and ascorbic acid. For a 0.50-g sample, the limits of determination are 10-2000 p.p.m. for Cu and Zn, and 5-5000 p.p.m. for Pb. As much as 40 % Fe or Ca. and 10 % Al, Mg, or Mn in the sample do not interfere. The proposed method can be applied to the determination of copper, zinc, and lead in a wide range of geological materials including iron- and manganese-rich, calcareous and carbonate samples. ?? 1976.

  9. Intracorneal ring segments implantation followed by same-day topography-guided PRK and corneal collagen CXL in low to moderate keratoconus.

    Science.gov (United States)

    Al-Tuwairqi, Waleed; Sinjab, Mazen M

    2013-01-01

    To evaluate the safety and efficacy of intrastromal corneal ring segments (ICRS) implantation followed by same-day topography-guided photorefractive keratectomy (PRK) and ultraviolet-A/riboflavin collagen cross-linking (CXL) in patients with low to moderate keratoconus. Patients with low to moderate keratoconus and contact lens intolerance were included in the study. All patients first underwent femtosecond laser-enabled placement of ICRS (Keraring, Mediphacos) (first step). Same-day topography-guided PRK and CXL (second step) were subsequently performed in all patients after the refraction was stable (average 6 months [range: 3 to 11 months]). Thirteen eyes from 13 patients were included in the study. Based on values before the first step and 6 months after the second step, significant improvements were noted in uncorrected distance visual acuity (0.7±0.32 logMAR vs 0.08±0.08 logMAR), corrected distance visual acuity (CDVA) (0.16±0.19 logMAR vs 0.02±0.04 log-MAR), sphere (-3.65±3.08 diopters [D] vs 0.06±1.6 D), astigmatism (-3.31±1.5 D vs -0.98±0.75 D), average K (47.28±1.99 D vs 41.42±3.22 D), and coma (2.36±1.23 μm vs 1.47±0.68 μm) (PPRK/CXL may be a reasonable option for improving visual acuity in patients with low to moderate keratoconus. Copyright 2013, SLACK Incorporated.

  10. Impact of chronic low to moderate alcohol consumption on blood lipid and heart energy profile in acetaldehyde dehydrogenase 2-deficient mice.

    Science.gov (United States)

    Fan, Fan; Cao, Quan; Wang, Cong; Ma, Xin; Shen, Cheng; Liu, Xiang-wei; Bu, Li-ping; Zou, Yun-zeng; Hu, Kai; Sun, Ai-jun; Ge, Jun-bo

    2014-08-01

    To investigate the roles of acetaldehyde dehydrogenase 2 (ALDH2), the key enzyme of ethanol metabolism, in chronic low to moderate alcohol consumption-induced heart protective effects in mice. Twenty-one male wild-type (WT) or ALDH2-knockout (KO) mice were used in this study. In each genotype, 14 animals received alcohol (2.5%, 5% and 10% in week 1-3, respectively, and 18% in week 4-7), and 7 received water for 7 weeks. After the treatments, survival rate and general characteristics of the animals were evaluated. Serum ethanol and acetaldehyde levels and blood lipids were measured. Metabolomics was used to characterize the heart and serum metabolism profiles. Chronic alcohol intake decreased the survival rate of KO mice by 50%, and significantly decreased their body weight, but did not affect those of WT mice. Chronic alcohol intake significantly increased the serum ethanol levels in both WT and KO mice, but KO mice had significantly higher serum acetaldehyde levels than WT mice. Chronic alcohol intake significantly increased the serum HDL cholesterol levels in WT mice, and did not change the serum HDL cholesterol levels in KO mice. After chronic alcohol intake, WT and KO mice showed differential heart and serum metabolism profiles, including the 3 main energy substrate types (lipids, glucose and amino acids) and three carboxylic acid cycles. Low to moderate alcohol consumption increases HDL cholesterol levels and improves heart energy metabolism profile in WT mice but not in ALDH2-KO mice. Thus, preserved ALDH2 function is essential for the protective effect of low to moderate alcohol on the cardiovascular system.

  11. Intake of Fruits and Vegetables with Low-to-Moderate Pesticide Residues Is Positively Associated with Semen-Quality Parameters among Young Healthy Men123

    Science.gov (United States)

    Gaskins, Audrey J; Williams, Paige L; Mendiola, Jaime; Levine, Hagai; Hauser, Russ; Swan, Shanna H; Chavarro, Jorge E

    2016-01-01

    Background: Numerous studies have shown that occupational or environmental pesticide exposure can affect male fertility. There is less evidence, however, regarding any potentially adverse effects of pesticide residues in foods on markers of male fertility potential. Objectives: We examined the relations between fruit and vegetable intake, considering pesticide residue status, and semen quality and serum concentrations of reproductive hormones in healthy young men. Methods: The Rochester Young Men's Study is a cross-sectional study that recruited men aged 18–22 y (n = 189) in Rochester, New York. Participants completed a questionnaire, provided a semen sample, had a blood sample drawn, and underwent a physical examination at enrollment. Semen samples were analyzed for total sperm count, sperm concentration, morphology, motility, ejaculate volume, total motile count, and total normal count. Dietary intake during the previous year was assessed by a validated food-frequency questionnaire. Fruit and vegetables were categorized as having high [Pesticide Residue Burden Score (PRBS) ≥4] or low-to-moderate (PRBS vegetable intake with semen variables and reproductive hormones while adjusting for potential confounding factors. Results: The total intake of fruit and vegetables was unrelated to semen quality. However, the intake of fruit and vegetables with low-to-moderate pesticide residues was associated with a higher total sperm count and sperm concentration, whereas the intake of fruit and vegetables with high pesticide residues was unrelated to semen quality. On average, men in the highest quartile of low-to-moderate-pesticide fruit and vegetable intake (≥2.8 servings/d) had a 169% (95% CI: 45%, 400%) higher total sperm count and a 173% (95% CI: 57%, 375%) higher sperm concentration than did men in the lowest quartile (vegetables, regardless of pesticide-residue status, was not associated with reproductive hormone concentrations. Conclusions: The consumption of fruit

  12. Estimation of lead and zinc in human hair using atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Kazi, S.; Kazi, T.G.; Kazi, G.H.

    1993-01-01

    Trace elements analysis in hair can be useful in studying the impact of environmental and dietary factors on human in general for lead and zinc content in hair. Samples of people of different age groups, sex with varied living habits of the individual living in different areas of Sind, urban as well as rural areas were of special interest to be studied to find correlation of socioeconomic factors and the presence of these elements in hair samples. The purpose of this study was to determine whether age, sex and physiological status and environmental pollution affect composition of hair. The method of sample preparation and use of atomic absorption techniques providing unequivocal and direct estimation of metals in ppm/ppb range to arrive upon conclusion. (author)

  13. The effects of low to moderate alcohol consumption and binge drinking in early pregnancy on behaviour in 5-year-old children: a prospective cohort study on 1628 children

    DEFF Research Database (Denmark)

    Skogerbø, Åshild; Kesmodel, Ulrik Schiøler; Denny, Clark

    2013-01-01

    To examine the effects of low to moderate maternal alcohol consumption and binge drinking in early pregnancy on behaviour in children at the age of 5 years.......To examine the effects of low to moderate maternal alcohol consumption and binge drinking in early pregnancy on behaviour in children at the age of 5 years....

  14. Determination of mercury, lead and cadmium in water by the CRA-atomic absorption spectrophotometry with solvent extraction

    International Nuclear Information System (INIS)

    Shim, Y.B.; Won, M.S.; Kim, C.J.

    1980-01-01

    The method of CRA-atomic absorption spectrophotometer with solvent extraction for the determination of mercury, lead and cadmium in water was studied. The optimum extracting conditions for CRA-atomic absorption spectrophotometry were the following: the complexes of mercury, lead and cadmium with dithizone were separated from the aqueous solution and concentrated into the 10 ml chloroform solution. Back extraction was performed; the concentrated mercury, lead and cadmium was extracted from the chloroform solution into the 10 ml 6-normal aqueous hydrochloric acid solution. In this case, recovery ratios were the following: mercury was 94.7%, lead 97.7% and cadmium 103.6%. The optimum operating conditions for the determination of mercury, lead and cadmium by the CRA-atomic absorption spectrophotometry also were investigated to test the dry step, ash step and atomization step for each metal. The experimental results of standard addition method were the following: the determination limit of each metal within 6% relative deviation was that lead was 0.04 ppb, and cadmium 0.01 ppb. Especially, mercury has been known impossible to determine by CRA-atomic absorption spectrophotometry until now. But in this study, mercury can be determined with CRA-atomic absorption spectrophotometer. Its determination limit was 4 ppb within 8% relative deviation. (author)

  15. CLINICAL STUDY TO EVALUATE THE VISUAL OUTCOME AND PATIENT COMFORT IN LASIK AND PHOTOREFRACTIVE KERATECTOMY IN LOW-TO-MODERATE MYOPIC ASTIGMATISM PATIENTS

    Directory of Open Access Journals (Sweden)

    Ashok Kumar P

    2017-04-01

    Full Text Available BACKGROUND To evaluate visual outcomes following LASIK and Photorefractive Keratectomy (PRK in low-to-moderate myopia and/or myopic astigmatism in age and refractive error matched eyes. MATERIALS AND METHODS Of a total 30 patients aged ≥21 years, 20 (40 eyes underwent LASIK and 10 (20 eyes underwent PRK for low-to-moderate myopia or myopic astigmatism. LASIK was performed with the Alcon wave light 500 and PRK with the alcohol application for epithelial removal. All ablations were performed using the same excimer laser system. One surgeon operated all patients by using an excimer laser (Alcon wave light 500 system. Age and refractive error matched patients were divided in two groups. Preoperative and one year postoperative uncorrected visual acuity, best corrected visual acuity and manifest refractions were recorded to compare the outcomes of both the procedures. Outcome measures to assess the patient comfort levels in both groups include postoperative pain and quality of vision. Other outcome measures to assess the wound healing includes intraoperative complications, corneal haze and corneal reepithelialisation. RESULTS Sixty eyes of 30 patients were found matched regarding age and refractive error. In PRK group, among 10 patients, 5 (50% were males and 5 (50% were females, whereas in Lasik group, males were 12 (60% and 8 (40% were female patients. Mean preoperative MRSE was -4.06 ± 1.00 Dioptres (D for LASIK versus -4.50 ± 1.25 D for PRK. Complete flap healing was achieved by postoperative day 4 in 86.9% of LASIK eyes versus complete reepithelialisation in 92.4% of PRK eyes. Using Fisher exact test, a significantly higher percentage of LASIK eyes compared to PRK eyes achieved 20/15 or better at 1 month (35.8% vs. 17.8%, P=0.031, 3 months (69.3% vs. 49.3%, P=0.004, 6 months (79.1% vs. 59.9%, P0.50 D occurred in 12.4% of LASIK eyes within the 3- and 12-month interval versus 25.7% of PRK eyes (P=0.04. Patients in both groups were happy

  16. Intake of Fruits and Vegetables with Low-to-Moderate Pesticide Residues Is Positively Associated with Semen-Quality Parameters among Young Healthy Men.

    Science.gov (United States)

    Chiu, Yu-Han; Gaskins, Audrey J; Williams, Paige L; Mendiola, Jaime; Jørgensen, Niels; Levine, Hagai; Hauser, Russ; Swan, Shanna H; Chavarro, Jorge E

    2016-05-01

    Numerous studies have shown that occupational or environmental pesticide exposure can affect male fertility. There is less evidence, however, regarding any potentially adverse effects of pesticide residues in foods on markers of male fertility potential. We examined the relations between fruit and vegetable intake, considering pesticide residue status, and semen quality and serum concentrations of reproductive hormones in healthy young men. The Rochester Young Men's Study is a cross-sectional study that recruited men aged 18-22 y (n = 189) in Rochester, New York. Participants completed a questionnaire, provided a semen sample, had a blood sample drawn, and underwent a physical examination at enrollment. Semen samples were analyzed for total sperm count, sperm concentration, morphology, motility, ejaculate volume, total motile count, and total normal count. Dietary intake during the previous year was assessed by a validated food-frequency questionnaire. Fruit and vegetables were categorized as having high [Pesticide Residue Burden Score (PRBS) ≥4] or low-to-moderate (PRBS sperm count and sperm concentration, whereas the intake of fruit and vegetables with high pesticide residues was unrelated to semen quality. On average, men in the highest quartile of low-to-moderate-pesticide fruit and vegetable intake (≥2.8 servings/d) had a 169% (95% CI: 45%, 400%) higher total sperm count and a 173% (95% CI: 57%, 375%) higher sperm concentration than did men in the lowest quartile (sperm counts in young men unselected by fertility status. This suggests that pesticide residues may modify the beneficial effects of fruit and vegetable intake on semen quality. © 2016 American Society for Nutrition.

  17. Changes in higher order aberrations after wavefront-guided PRK for correction of low to moderate myopia and myopic astigmatism: two-year follow-up.

    Science.gov (United States)

    Wigledowska-Promienska, D; Zawojska, I

    2007-01-01

    To assess efficacy, safety, and changes in higher order aberrations after wavefront-guided photorefractive keratectomy (PRK) in comparison with conventional PRK for low to moderate myopia with myopic astigmatism using a WASCA Workstation with the MEL 70 G-Scan excimer laser. A total of 126 myopic or myopic-astigmatic eyes of 112 patients were included in this retrospective study. Patients were divided into two groups: Group 1, the study group; and Group 2, the control group. Group 1 consisted of 78 eyes treated with wavefront-guided PRK. Group 2 consisted of 48 eyes treated with spherocylindrical conventional PRK. Two years postoperatively, in Group 1, 5% of eyes achieved an uncorrected visual acuity (UCVA) of 0.05; 69% achieved a UCVA of 0.00; 18% of eyes experienced enhanced visual acuity of -0.18 and 8% of -0.30. In Group 2, 8% of eyes achieved a UCVA of 0.1; 25% achieved a UCVA of 0.05; and 67% achieved a UCVA of 0.00 according to logMAR calculation method. Total higher-order root-mean square increased by a factor 1.18 for Group 1 and 1.6 for Group 2. There was a significant increase of coma by a factor 1.74 in Group 2 and spherical aberration by a factor 2.09 in Group 1 and 3.56 in Group 2. The data support the safety and effectiveness of the wavefront-guided PRK using a WASCA Workstation for correction of low to moderate refractive errors. This method reduced the number of higher order aberrations induced by excimer laser surgery and improved uncorrected and spectacle-corrected visual acuity when compared to conventional PRK.

  18. Blood pressure hyperreactivity: an early cardiovascular risk in normotensive men exposed to low-to-moderate inorganic arsenic in drinking water.

    Science.gov (United States)

    Kunrath, Julie; Gurzau, Eugen; Gurzau, Anca; Goessler, Walter; Gelmann, Elyssa R; Thach, Thu-Trang; McCarty, Kathleen M; Yeckel, Catherine W

    2013-02-01

    Essential hypertension is associated with chronic exposure to high levels of inorganic arsenic in drinking water. However, early signs of risk for developing hypertension remain unclear in people exposed to chronic low-to-moderate inorganic arsenic. We evaluated cardiovascular stress reactivity and recovery in healthy, normotensive, middle-aged men living in an arsenic-endemic region of Romania. Unexposed (n = 16) and exposed (n = 19) participants were sampled from communities based on WHO limits for inorganic arsenic in drinking water (Water sources and urine samples were collected and analyzed for inorganic arsenic and its metabolites. Functional evaluation of blood pressure included clinical, anticipatory, cold pressor test, and recovery measurements. Blood pressure hyperreactivity was defined as a combined stress-induced change in SBP (> 20 mmHg) and DBP (>15 mmHg). Drinking water inorganic arsenic averaged 40.2 ± 30.4 and 1.0 ± 0.2 μg/l for the exposed and unexposed groups, respectively (P pressure hyperreactivity to both anticipatory stress (47.4 vs. 12.5%; P = 0.035) and cold stress (73.7 vs. 37.5%; P = 0.044). Moreover, the exposed group exhibited attenuated blood pressure recovery from stress and a greater probability of persistent hypertensive responses (47.4 vs. 12.5%; P = 0.035). Inorganic arsenic exposure increased stress-induced blood pressure hyperreactivity and poor blood pressure recovery, including persistent hypertensive responses in otherwise healthy, clinically normotensive men. Drinking water containing even low-to-moderate inorganic arsenic may act as a sympathetic nervous system trigger for hypertension risk.

  19. Application of extraction-chromatographic concentration to atomic absorption determination of lead and cadmium in drinking and sea water

    International Nuclear Information System (INIS)

    Bol'shova, T.A.; Agapkina, G.I.; Ershova, N.I.; Narankho, K.E.

    1988-01-01

    To increase the detection limits for lead and cadmium atomic-absorption determination in natural waters methods of extraction-chromatographic concentration of these metals using tri-n-octylamine (TOA) on polytetrafluoroethylene (PTFE) is developed. Chromatograpy was carried out from 1.5-2.0 M HBr solutions. For cadmium and lead elution acetic acid was used. It is shown that extraction-chromatographic concentration permits to decrease limits of metal atomic-absorption detection by 10 3 with the 500 ml volume sample analysis

  20. Efficacy and safety of transcatheter aortic valve replacement in aortic stenosis patients at low to moderate surgical risk: a comprehensive meta-analysis.

    Science.gov (United States)

    Elmaraezy, Ahmed; Ismail, Ammar; Abushouk, Abdelrahman Ibrahim; Eltoomy, Moutaz; Saad, Soha; Negida, Ahmed; Abdelaty, Osama Mahmoud; Abdallah, Ahmed Ramadan; Aboelfotoh, Ahmed Magdy; Hassan, Hossam Mahmoud; Elmaraezy, Aya Gamal; Morsi, Mahmoud; Althaher, Farah; Althaher, Moath; AlSafadi, Ammar M

    2017-08-24

    Recently, transcatheter aortic valve replacement (TAVR) has become the procedure of choice in high surgical risk patients with aortic stenosis (AS). However, its value is still debated in operable AS cases. We performed this meta-analysis to compare the safety and efficacy of TAVR to surgical aortic valve replacement (SAVR) in low-to-moderate surgical risk patients with AS. A systematic search of five authentic databases retrieved 11 eligible studies (20,056 patients). Relevant Data were pooled as risk ratios (RRs) or standardized mean differences (SMD), with their 95% confidence interval, using Comprehensive Meta-Analysis and RevMan software for windows. At one-year of follow-up, the pooled effect-estimates showed no significant difference between TAVR and SAVR groups in terms of all-cause mortality (RR 1.02, 95% CI [0.83, 1.26], stroke (RR 0.83, 95%CI [0.56, 1.21]), myocardial infarction (RR 0.82, 95% CI [0.57, 1.19]), and length of hospital stay (SMD -0.04, 95% CI [-0.34, 0.26]). The incidence of major bleeding (RR 0.45, 95% CI [0.24, 0.86]) and acute kidney injury (RR 0.52, 95% CI [0.30, 0.88]) was significantly lower in the TAVR group, compared to the SAVR group. However, TAVR was associated with a higher risk of permanent pacemaker implantation (RR 2.57, 95% CI [1.36, 4.86]), vascular-access complications at 1 year (RR 1.99, 95%CI [1.04, 3.80]), and paravalvular aortic regurgitation at 30 days (RR 3.90, 95% CI [1.25, 12.12]), compared to SAVR. Due to the comparable mortality rates in SAVR and TAVR groups and the lower risk of life-threatening complications in the TAVR group, TAVR can be an acceptable alternative to SAVR in low-to-moderate risk patients with AS. However, larger trials with longer follow-up periods are required to compare the long-term outcomes of both techniques.

  1. Vector analysis of low to moderate astigmatism with small incision lenticule extraction (SMILE): results of a 1-year follow-up.

    Science.gov (United States)

    Zhang, Jiamei; Wang, Yan; Wu, Wenjing; Xu, Lulu; Li, Xiaojing; Dou, Rui

    2015-01-24

    To evaluate the refractive outcomes for the correction of low to moderate astigmatism up to 1 year following small incision lenticule extraction (SMILE) surgery. This retrospective study enrolled 98 eyes from 98 patients who underwent SMILE surgery for the correction of myopia and astigmatism. Only right eyes were included in this study to avoid the bias of orientation errors. The vector method was used to analyze the outcomes of astigmatism at 1 month, 6 months and 12 months after the procedure, including the double-angle plots, correction index (CI), index of success (IOS), angle of error (AofE) and magnitude of error (MofE). The effectiveness, safety, stability and predictability were also investigated during the 12-month follow-up. The preoperative cylinder ranged from -2.75 D to -0.25 D (average of -0.90±0.68 D), and the mean postoperative cylinder values were -0.24±0.29 D, -0.24±0.29 D, and -0.20±0.27 D at 1 month, 6 months, and 12 months, respectively. The mean astigmatism in vector form was -0.14 D×27.19° at 1 month, -0.13 D×27.29° at 6 months, and -0.10 D×28.63° at 12 months after surgery. The CI was 1.00±0.32 and IOS was 0.29±0.44 at the 12-month follow-up. Significant negative correlations were found between the CI and absolute target induced astigmatism (TIA) value, and positive correlations were found between the IOS and absolute AofE value (Psafe in correcting low to moderate astigmatism, and stable refractive outcomes were observed at the long-term follow-up. The undercorrection of astigmatism could possibly be influenced by attempted astigmatism correction preoperatively, the axis rotation during the surgery or wound healing postoperatively. This study suggested that nomograms should be adjusted in correcting astigmatism with SMILE surgery.

  2. Low to Moderate Average Alcohol Consumption and Binge Drinking in Early Pregnancy: Effects on Choice Reaction Time and Information Processing Time in Five-Year-Old Children.

    Directory of Open Access Journals (Sweden)

    Tina R Kilburn

    Full Text Available Deficits in information processing may be a core deficit after fetal alcohol exposure. This study was designed to investigate the possible effects of weekly low to moderate maternal alcohol consumption and binge drinking episodes in early pregnancy on choice reaction time (CRT and information processing time (IPT in young children.Participants were sampled based on maternal alcohol consumption during pregnancy. At the age of 60-64 months, 1,333 children were administered a modified version of the Sternberg paradigm to assess CRT and IPT. In addition, a test of general intelligence (WPPSI-R was administered.Adjusted for a wide range of potential confounders, this study showed no significant effects of average weekly maternal alcohol consumption during pregnancy on CRT or IPT. There was, however, an indication of slower CRT associated with binge drinking episodes in gestational weeks 1-4.This study observed no significant effects of average weekly maternal alcohol consumption during pregnancy on CRT or IPT as assessed by the Sternberg paradigm. However, there were some indications of CRT being associated with binge drinking during very early pregnancy. Further large-scale studies are needed to investigate effects of different patterns of maternal alcohol consumption on basic cognitive processes in offspring.

  3. Habitual coffee and tea drinkers experienced increases in blood pressure after consuming low to moderate doses of caffeine; these increases were larger upright than in the supine posture.

    Science.gov (United States)

    McMullen, Michael K; Whitehouse, Julie M; Shine, Gillian; Towell, Anthony

    2011-04-01

    Caffeine users have been encouraged to consume caffeine regularly to maintain their caffeine tolerance and so avoid caffeine's acute pressor effects. In controlled conditions complete caffeine tolerance to intervention doses of 250 mg develops rapidly following several days of caffeine ingestion, nevertheless, complete tolerance is not evident for lower intervention doses. Similarly complete caffeine tolerance to 250 mg intervention doses has been demonstrated in habitual coffee and tea drinkers' but for lower intervention doses complete tolerance is not evident. This study investigated a group of habitual caffeine users following their self-determined consumption pattern involving two to six servings daily. Cardiovascular responses following the ingestion of low to moderate amounts caffeine (67, 133 and 200 mg) were compared with placebo in a double-blind, randomised design without caffeine abstinence. Pre-intervention and post-intervention (30 and 60 min) 90 s continuous cardiovascular recordings were obtained with the Finometer in both the supine and upright postures. Participants were 12 healthy habitual coffee and tea drinkers (10 female, mean age 36). Doses of 67 and 133 mg increased systolic pressure in both postures while in the upright posture diastolic pressure and aortic impedance increased while arterial compliance decreased. These vascular changes were larger upright than supine for 133 mg caffeine. Additionally 67 mg caffeine increased dp/dt and indexed peripheral resistance in the upright posture. For 200 mg caffeine there was complete caffeine tolerance. Cardiovascular responses to caffeine appear to be associated with the size of the intervention dose. Habitual tea and coffee drinking does not generate complete tolerance to caffeine as has been previously suggested. Both the type and the extent of caffeine induced cardiovascular changes were influenced by posture.

  4. Comparative experimental and modeling study of the low- to moderate-temperature oxidation chemistry of 2,5-dimethylfuran, 2-methylfuran, and furan

    KAUST Repository

    Tran, Luc-Sy; Wang, Zhandong; Carstensen, Hans-Heinrich; Hemken, Christian; Battin-Leclerc, Fré dé rique; Kohse-Hö inghaus, Katharina

    2017-01-01

    The reaction chemistry of furanic fuels, proposed as next-generation bio-derived fuels, has been a target of recent studies. However, quantitative intermediate species profiles at low- to moderate-temperature (LMT) conditions remain scarce. The present paper reports the first systematic full speciation dataset in the temperature range 730–1170 K for three furanic fuels, 2,5-dimethylfuran (DMF), 2-methylfuran (MF), and furan, measured for different equivalence ratios under near-identical LMT conditions in a flow reactor at 1 bar. More than 35 species including reactants, intermediate species, and products were analyzed using electron ionization (EI) molecular-beam mass spectrometry (MBMS). These experimental results provided motivation to extend a previous single joint mechanism for the three furanic fuels, developed for the high-temperature regime in low-pressure premixed flames, to include the LMT oxidation chemistry. A decisive difference of the present mechanism versus all previously reported models is a more complete description of fuel radical reactions for LMT oxidation, obtained from theoretical calculations of thermodynamic properties and rate constants. The experimentally observed differences in fuel conversion behavior and species distribution between the three fuels have been compared to model predictions using the newly extended mechanism. The dependence of fuel conversion on equivalence ratio decreases significantly from DMF to furan, a behavior consistent with the different number of lateral methyl groups in the fuel structure. All three furanic fuels, especially DMF, produce several highly toxic oxygenated species including acrolein, methyl vinyl ketone, furfural, and phenol. These toxic species were found to be products of the primary reactions of these fuels, and these undesirable trends could be explained satisfactorily by the present model, pointing to some caution with regard to the potential emission spectra under LMT conditions.

  5. Noninvasive Coronary Angiography using 64-Detector-Row Computed Tomography in Patients with a Low to Moderate Pretest Probability of Significant Coronary Artery Disease

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, T.; Mohrs, O.K.; Magedanz, A.; Nowak, B.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A. [Dept. of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen (Germany)

    2007-04-15

    Purpose: To evaluate the value of 64-detector-row computed tomography for ruling out high-grade coronary stenoses in patients with a low to moderate pretest probability of significant coronary artery disease. Material and Methods: The study included 61 patients with a suspicion of coronary artery disease on the basis of atypical angina or ambiguous findings in noninvasive stress testing and a class II indication for invasive coronary angiography (ICA). All patients were examined by 64-detector-row computed tomography angiography (CTA) and ICA. On a coronary segmental level, the presence of significant (>50% diameter) stenoses was examined. Results: In a total of 915 segments, CTA detected 62 significant stenoses. Thirty-four significant stenoses were confirmed by ICA, whereas 28 stenoses could not be confirmed by ICA. Twenty-two of them showed wall irregularities on ICA, and six were angiographically normal. Accordingly, on a coronary segmental basis, 28 false-positive and 0 false-negative findings resulted in a sensitivity of 100%, a specificity of 96.8%, a positive predictive value of 54.8%, and a negative predictive value of 100%. The diagnostic accuracy was 96.9%. Conclusion: Sixty-four-detector-row computed tomography reliably detects significant coronary stenoses in patients with suspected coronary artery disease and appears to be helpful in the selection of patients who need to undergo ICA. Calcified and non-calcified plaques are detected. Grading of stenoses in areas with calcification is difficult. Frequently, stenosis severity is overestimated by 64-detector-row computed tomography.

  6. Noninvasive Coronary Angiography using 64-Detector-Row Computed Tomography in Patients with a Low to Moderate Pretest Probability of Significant Coronary Artery Disease

    International Nuclear Information System (INIS)

    Schlosser, T.; Mohrs, O.K.; Magedanz, A.; Nowak, B.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A.

    2007-01-01

    Purpose: To evaluate the value of 64-detector-row computed tomography for ruling out high-grade coronary stenoses in patients with a low to moderate pretest probability of significant coronary artery disease. Material and Methods: The study included 61 patients with a suspicion of coronary artery disease on the basis of atypical angina or ambiguous findings in noninvasive stress testing and a class II indication for invasive coronary angiography (ICA). All patients were examined by 64-detector-row computed tomography angiography (CTA) and ICA. On a coronary segmental level, the presence of significant (>50% diameter) stenoses was examined. Results: In a total of 915 segments, CTA detected 62 significant stenoses. Thirty-four significant stenoses were confirmed by ICA, whereas 28 stenoses could not be confirmed by ICA. Twenty-two of them showed wall irregularities on ICA, and six were angiographically normal. Accordingly, on a coronary segmental basis, 28 false-positive and 0 false-negative findings resulted in a sensitivity of 100%, a specificity of 96.8%, a positive predictive value of 54.8%, and a negative predictive value of 100%. The diagnostic accuracy was 96.9%. Conclusion: Sixty-four-detector-row computed tomography reliably detects significant coronary stenoses in patients with suspected coronary artery disease and appears to be helpful in the selection of patients who need to undergo ICA. Calcified and non-calcified plaques are detected. Grading of stenoses in areas with calcification is difficult. Frequently, stenosis severity is overestimated by 64-detector-row computed tomography

  7. Comparative experimental and modeling study of the low- to moderate-temperature oxidation chemistry of 2,5-dimethylfuran, 2-methylfuran, and furan

    KAUST Repository

    Tran, Luc-Sy

    2017-04-21

    The reaction chemistry of furanic fuels, proposed as next-generation bio-derived fuels, has been a target of recent studies. However, quantitative intermediate species profiles at low- to moderate-temperature (LMT) conditions remain scarce. The present paper reports the first systematic full speciation dataset in the temperature range 730–1170 K for three furanic fuels, 2,5-dimethylfuran (DMF), 2-methylfuran (MF), and furan, measured for different equivalence ratios under near-identical LMT conditions in a flow reactor at 1 bar. More than 35 species including reactants, intermediate species, and products were analyzed using electron ionization (EI) molecular-beam mass spectrometry (MBMS). These experimental results provided motivation to extend a previous single joint mechanism for the three furanic fuels, developed for the high-temperature regime in low-pressure premixed flames, to include the LMT oxidation chemistry. A decisive difference of the present mechanism versus all previously reported models is a more complete description of fuel radical reactions for LMT oxidation, obtained from theoretical calculations of thermodynamic properties and rate constants. The experimentally observed differences in fuel conversion behavior and species distribution between the three fuels have been compared to model predictions using the newly extended mechanism. The dependence of fuel conversion on equivalence ratio decreases significantly from DMF to furan, a behavior consistent with the different number of lateral methyl groups in the fuel structure. All three furanic fuels, especially DMF, produce several highly toxic oxygenated species including acrolein, methyl vinyl ketone, furfural, and phenol. These toxic species were found to be products of the primary reactions of these fuels, and these undesirable trends could be explained satisfactorily by the present model, pointing to some caution with regard to the potential emission spectra under LMT conditions.

  8. Bismuth as a general internal standard for lead in atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Bechlin, Marcos A.; Fortunato, Felipe M.; Ferreira, Edilene C.; Neto, José A. Gomes; Nóbrega, Joaquim A.; Donati, George L.; Jones, Bradley T.

    2014-01-01

    Highlights: • Single internal standard is commonly proposed for definite application in AAS. • Internal standard for general use in AAS techniques is original. • Bi showed efficiency as internal standard for Pb determinations by FAAS and GFAAS. • Assorted samples were analyzed and accurate results were found. - Abstract: Bismuth was evaluated as internal standard for Pb determination by line source flame atomic absorption spectrometry (LS FAAS), high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) and line source graphite furnace atomic absorption spectrometry (LS GFAAS). Analysis of samples containing different matrices indicated close relationship between Pb and Bi absorbances. Correlation coefficients of calibration curves built up by plotting A Pb /A Bi versus Pb concentration were higher than 0.9953 (FAAS) and higher than 0.9993 (GFAAS). Recoveries of Pb improved from 52–118% (without IS) to 97–109% (IS, LS FAAS); 74–231% (without IS) to 96–109% (IS, HR-CS FAAS); and 36–125% (without IS) to 96–110% (IS, LS GFAAS). The relative standard deviations (n = 12) were reduced from 0.6–9.2% (without IS) to 0.3–4.3% (IS, LS FAAS); 0.7–7.7% (without IS) to 0.1–4.0% (IS, HR-CS FAAS); and 2.1–13% (without IS) to 0.4–5.9% (IS, LS GFAAS)

  9. Bismuth as a general internal standard for lead in atomic absorption spectrometry.

    Science.gov (United States)

    Bechlin, Marcos A; Fortunato, Felipe M; Ferreira, Edilene C; Gomes Neto, José A; Nóbrega, Joaquim A; Donati, George L; Jones, Bradley T

    2014-06-11

    Bismuth was evaluated as internal standard for Pb determination by line source flame atomic absorption spectrometry (LS FAAS), high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) and line source graphite furnace atomic absorption spectrometry (LS GFAAS). Analysis of samples containing different matrices indicated close relationship between Pb and Bi absorbances. Correlation coefficients of calibration curves built up by plotting A(Pb)/A(Bi)versus Pb concentration were higher than 0.9953 (FAAS) and higher than 0.9993 (GFAAS). Recoveries of Pb improved from 52-118% (without IS) to 97-109% (IS, LS FAAS); 74-231% (without IS) to 96-109% (IS, HR-CS FAAS); and 36-125% (without IS) to 96-110% (IS, LS GFAAS). The relative standard deviations (n=12) were reduced from 0.6-9.2% (without IS) to 0.3-4.3% (IS, LS FAAS); 0.7-7.7% (without IS) to 0.1-4.0% (IS, HR-CS FAAS); and 2.1-13% (without IS) to 0.4-5.9% (IS, LS GFAAS). Copyright © 2014 Elsevier B.V. All rights reserved.

  10. An analysis of lead (Pb) from human hair samples (20-40 years of age) by atomic absorption spectrophotometry

    Energy Technology Data Exchange (ETDEWEB)

    Gelsano, Flordeliza K; Timing, Laurie D

    2003-02-17

    This analysis of lead from human hair samples in five different groups namely scavengers from Payatas Quezon City, tricycle drivers, car shop workers, paint factory workers, and students from Polytechnic University of the Philippines. The people from Nagcarlan, Laguna represented as a ''base-line value'' or as a control group. The method applied was acid digestion using HNO{sub 3} and HClO{sub 4} then the samples were subjected to atomic absorption spectrophotometer. In terms of lead found from hair, the scavengers from Payatas Q.C. obtained high exposure of lead among the samples that were tested. The result of the analysis of concentration of lead was expressed in mg/L. (Authors)

  11. An analysis of lead (Pb) from human hair samples (20-40 years of age) by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Gelsano, Flordeliza K.; Timing, Laurie D.

    2003-01-01

    This analysis of lead from human hair samples in five different groups namely scavengers from Payatas Quezon City, tricycle drivers, car shop workers, paint factory workers, and students from Polytechnic University of the Philippines. The people from Nagcarlan, Laguna represented as a ''base-line value'' or as a control group. The method applied was acid digestion using HNO 3 and HClO 4 then the samples were subjected to atomic absorption spectrophotometer. In terms of lead found from hair, the scavengers from Payatas Q.C. obtained high exposure of lead among the samples that were tested. The result of the analysis of concentration of lead was expressed in mg/L. (Authors)

  12. Urban Airborne Lead: X-Ray Absorption Spectroscopy Establishes Soil as Dominant Source

    OpenAIRE

    Pingitore, Nicholas E.; Clague, Juan W.; Amaya, Maria A.; Maciejewska, Beata; Reynoso, Jes?s J.

    2009-01-01

    BACKGROUND: Despite the dramatic decrease in airborne lead over the past three decades, there are calls for regulatory limits on this potent pediatric neurotoxin lower even than the new (2008) US Environmental Protection Agency standard. To achieve further decreases in airborne lead, what sources would need to be decreased and what costs would ensue? Our aim was to identify and, if possible, quantify the major species (compounds) of lead in recent ambient airborne particulate matter collected...

  13. Matched population comparison of visual outcomes and patient satisfaction between 3 modalities for the correction of low to moderate myopic astigmatism

    Directory of Open Access Journals (Sweden)

    Ganesh S

    2017-07-01

    Full Text Available Sri Ganesh, Sheetal Brar, Archana Pawar Phacorefractive Department, Nethradhama Superspeciality Eye Hospital, Bengaluru, Karnataka, India Purpose: To compare toric implantable collamer lens (T-ICL, femto-LASIK, and ReLEx SMILE for the treatment of low to moderate myopic astigmatism in terms of long-term visual and refractive outcomes and predictability of astigmatic correction.Materials and methods: The study included 30 eyes from 30 patients between the age groups of 21 and 40 years, undergoing bilateral surgery with any of the three procedures – T-ICL, femto-LASIK, or ReLEx SMILE – for correction of myopic astigmatism within the range of −3 to −8 D spherical equivalent (SE, with a minimum astigmatism of −0.75 D. Patients were followed up at day 1, 1 month, 6 months, and 1 year.Results: At 1 year, the mean cylinder reduced to −0.21±0.28, −0.17±0.36, and −0.22±0.28 D in the T-ICL, femto-LASIK, and ReLEx SMILE group, respectively. The predictability of astigmatism correction was comparable, with no statistically significant difference between the 3 groups (P>0.05. A total of 97% of eyes in ReLEx SMILE achieved a uncorrected distance visual acuity of 20/20 or better, compared to T-ICL (93% and FS-LASIK (90%. However, gain in lines of corrected distant visual acuity (CDVA was maximum in T-ICL group (60%. Four eyes in the femto-LASIK group had loss of CDVA by one line. Three eyes required exchange due to high vault and rotation of the T-ICL, which did not affect the final outcome.Conclusion: All 3 modalities were effective for myopic astigmatism at the end of 1 year. Quality of vision and patient satisfaction with T-ICL and ReLEx SMILE were similar and better than FS-LASIK. However, slight chances of postoperative rotation and exchange exist with T-ICL, which warrant thorough preoperative planning. Keywords: toric implantable collamer lens, femtosecond LASIK, ReLEx SMILE, myopic astigmatism

  14. Optical and X-ray absorption spectroscopy in lead doped lithium fluoride crystals

    Energy Technology Data Exchange (ETDEWEB)

    Somma, F; Aloe, P; D' Acapito, F; Montereali, R M; Polosan, S; Secu, M; Vincenti, M A, E-mail: somma@fis.uniroma3.it

    2010-11-15

    LiF:Pb doped crystals were successfully grown by Kyropoulos method, starting with drying powders. The presence of Pb{sup 2+} ions in the LiF crystals were evidenced by the absorption band at 278 nm and by 375 nm photoluminescence. The presence of some other Pb structures with oxygen compounds in the as made samples was evidenced, decreasing after some annealing procedures. The local environment and valence state of Pb in LiF were studied by X-ray Absorption Spectroscopy at the Pb L{sub III} and L{sub I} edges. XANES data reveal that Pb is present as Pb{sup 2+} whereas EXAFS data show that it is incorporated in the crystal and not forming PbF{sub 2} precipitates. Identical spectra are obtained for samples as prepared and after thermal annealing up to 650 deg. C demonstrating the stability of the incorporation site. Also the concentration of Pb in the crystal has no effect on the location site of the metal as the same spectrum is obtained for specimens with different dopant concentrations.

  15. Lead absorption in sheep fed forage contaminated with motor vehicle exhaust gases

    Energy Technology Data Exchange (ETDEWEB)

    Zuber, R; Bovay, E; Luginbuehl, H R; Loenig, H

    1972-01-01

    For a period of 24 weeks three sheep received hay contaminated with lead deposits from motor vehicle exhaust gases. The aim of this study was to compare the lead accumulation in different organs and tissues of two young sheep (I and II) consuming every day forage containing 8 and 73 ppM lead respectively (= milligrams per kg of dried substance). A third animal (III) was fed with forage containing 73 ppM Pb and received in addition water with 200 mg Pb/liter. The analyses made after slaughtering of the animals revealed a marked accumulation of lead in the liver, the bones of the pelvis, the kidneys, and the spleen. However, a notable proportion of lead is also excreted with the urine and feces. Histological studies revealed some changes in the hepatocytes of animals II and III. These lesions were more significant in animal III, which received the highest level of lead, than in animal II. It is possible that these alterations have been caused by toxic substances.

  16. Arsenic Exposure From Drinking Water and the Incidence of CKD in Low to Moderate Exposed Areas of Taiwan: A 14-Year Prospective Study.

    Science.gov (United States)

    Hsu, Ling-I; Hsieh, Fang-I; Wang, Yuan-Hung; Lai, Tai-Shuan; Wu, Meei-Maan; Chen, Chien-Jen; Chiou, Hung-Yi; Hsu, Kuang-Hung

    2017-12-01

    Arsenic exposure is associated with decreased kidney function. The association between low to moderate arsenic exposure and kidney disease has not been fully clarified. The association between arsenic exposure from drinking water and chronic kidney disease (CKD) was examined in a long-term prospective observational study. 6,093 participants 40 years and older were recruited from arseniasis-endemic areas in northeastern Taiwan. Arsenic levels were 28.0, 92.8, and 295.7μg/L at the 50th, 75th, and 90th percentiles, respectively. Well-water arsenic and urinary total arsenic (inorganic plus methylated arsenic species) concentrations, adjusted for urinary creatinine concentration. Kidney diseases (ICD-9 codes: 250.4, 274.1, 283.11, 403.*1, 404.*2, 404.*3, 440.1, 442.1, 447.3, or 580-589) and CKD (ICD-9 code: 585) ascertained using Taiwan's National Health Insurance database 1998 to 2011. HRs contrasting CKD risk across arsenic exposure levels were estimated using Cox regression. Prevalence ORs for proteinuria (protein excretion ≥ 200mg/g) comparing quartiles of total urinary arsenic concentrations were estimated using logistic regression. We identified 1,104 incident kidney disease cases, including 447 CKD cases (incidence rates, 166.5 and 67.4 per 10 4 person-years, respectively). A dose-dependent association between well-water arsenic concentrations and kidney diseases was observed after adjusting for age, sex, education, body mass index, cigarette smoking, alcohol consumption, and analgesic use. Using arsenic concentration ≤ 10.0μg/L as reference, multivariable-adjusted HRs for incident CKD were 1.12 (95% CI, 0.88-1.42), 1.33 (95% CI, 1.03-1.72), and 1.33 (95% CI, 1.00-1.77) for arsenic concentrations of 10.1 to 49.9, 50.0 to 149.9, and ≥150.0μg/L, respectively (P for trend=0.02). The association between arsenic concentration and kidney diseases was stronger for women (P for interaction=0.06). Arsenic values in the range of 50th to 75th and 75th to 100th

  17. Influence of Na, K, Ca and Mg on lead atomization by tungsten coil atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Oliveira Pedro V. de

    2000-01-01

    Full Text Available The atomization of lead in an electrothermal tungsten coil atomizer in the presence and absence of Na+, K+, Ca2+ and Mg2+ was investigated with the objective of understanding the interference processes. The lead atomization was less affected by Ca2+ and Mg2+ than by Na+ and K+. In the absence of concomitants, lead atomization efficiency was improved by the presence of H2 (10% v/v in the purge gas composition, during pyrolysis and atomization steps. The interference caused by Na+ and Ca2+ was negligible when the pyrolysis step was accomplished without H2 in the purge gas composition. The results showed that Na+, K+, Ca2+ and Mg2+ are directly involved in competition reactions for H2 in condensed phase.

  18. Lead preconcentration in synthetic samples with triton x-114 in the cloud point extraction and analysis by atomic absorption (EAAF)

    International Nuclear Information System (INIS)

    Zegarra Pisconti, Marixa; Cjuno Huanca, Jesus

    2015-01-01

    A methodology was developed about lead preconcentration in water samples that were added dithizone as complexing agent, previously dissolved in the nonionic surfactant Triton X-114, until the formation of the critical micelle concentration and the cloud point temperature. The centrifuged system gave a precipitate with high concentrations of Pb (II) that was measured by atomic absorption spectroscopy with flame (EAAF). The method has proved feasible to be implemented as a method of preconcentration and analysis of Pb in aqueous samples with concentrations less than 1 ppm. Several parameters were evaluated to obtain a percentage recovery of 89.8%. (author)

  19. Diffuse X-ray scattering and far infrared absorption of barium and lead β" aluminas

    DEFF Research Database (Denmark)

    Hayes, W.; Kjær, Kristian; Pratt, F. L.

    1985-01-01

    The authors have carried out high-momentum-resolution studies in diffuse X-ray scattering of barium and lead B" aluminas in the temperature range 20-700 degrees C. They have also measured the vibrational spectra of these compounds between 2K and 300K in the energy range 10-100 cm-1. The results...

  20. Screening Technique for Lead and Cadmium in Toys and Other Materials Using Atomic Absorption Spectroscopy

    Science.gov (United States)

    Brouwer, Henry

    2005-01-01

    A simple procedure to quickly screen different consumer products for the presence of lead, cadmium, and other metals is described. This screening technique avoids expending a lot of preparation time on samples known to contain low levels of hazardous metals where only samples testing positive for the desired elements need to be analyzed…

  1. A l% and 1cm Perspective Leads to a Novel CDOM Absorption Algorithm

    Science.gov (United States)

    Morrow, J. H.; Hooker, S. B.; Matsuoka, A.

    2012-01-01

    A next-generation in-water profiler designed to measure the apparent optical properties of seawater was developed and validated across a wide dynamic range of water properties. This new Compact-Optical Profiling System (C-OPS) design uses a novel, kite-shaped, free-falling backplane with adjustable buoyancy and is based on 19 state-of-the-art microradiometers, spanning 320-780 nm. Data collected as part of the field commissioning were of a previously unachievable quality and showed that systematic uncertainties in the sampling protocols were discernible at the 1% optical and 1cm depth resolution levels. A sensitivity analysis as a function of three water types, established by the peak in the remote sensing reflectance spectra, revealed which water types and spectral domains were the most indicative of data acquisition uncertainties. The unprecedented vertical resolution of C-OPS measurements provided near-surface data products at the spectral endpoints with a quality level that has not been obtainable. The improved data allowed development of an algorithm for predicting the spectral absorption due to chromophoric dissolved organic matter (CDOM) using ratios of diffuse attenuation coefficients with over 99% of the variance in the data explained.

  2. Mental Health in Low-to-Moderate Risk Preterm, Low Birth Weight, and Small for Gestational Age Children at 4 to 5 Years: The Role of Early Maternal Parenting

    Science.gov (United States)

    Westrupp, Elizabeth M.; Mensah, Fiona K.; Giallo, Rebecca; Cooklin, Amanda; Nicholson, Jan M.

    2012-01-01

    Objectives: The majority of children born preterm, with low birth weight, or small for gestational age are born with low-to-moderate risk (LTM), yet most research focuses on the high-risk group. Little is known about whether children with LTM perinatal risk are at greater risk for mental health problems, or what the role of early maternal…

  3. Determination of silver, bismuth, cadmium, copper, lead, and zinc in geologic materials by atomic absorption spectrometry with tricaprylylmethylammonium chloride

    Science.gov (United States)

    Viets, J.G.

    1978-01-01

    Interferences commonly encountered in the determination of silver, bismuth, cadmium, copper, lead, and zinc at crustal abundance levels are effectively eliminated using a rapid, sensitive, organic extraction technique. A potassium chlorate-hydrochloric acid digestion solubilizes the metals not tightly bound in the silicate lattice of rocks, soils, and stream sediments. The six metals are selectively extracted into a 10% Aliquat 336-MIBK organic phase in the presence of ascorbic acid and potassium iodide. Metals in the organic extract are determined by flame atomic absorption spectrometry to the 0.02-ppm level for silver, cadmium, copper, and zinc and to the 0.2-ppm level for bismuth and lead with a maximum relative standard deviation of 18.8% for known reference samples. An additional hydrofluoric acid digestion may be used to determine metals substituted in the silicate lattice.

  4. Determination of lead in water by electrothermal atomic absorption spectrometry with a nickel(II)-ammonium tartrate modifier

    International Nuclear Information System (INIS)

    Sekerka, I.; Lechner, J.F.

    1991-01-01

    A method is described for the determination of low concentrations of lead in water samples. Atomic absorption spectrometry is used with a tungsten ribbon furnace and Zeeman background correction. Interferences are eliminated by the addition of ammonium tartrate and nickel(II) nitrate to the samples to act as a matrix modifier and adjust the pH. The results show the superior performance of this modifier over other types used conventionally. The detection limit is 1 μg l -1 relative standard deviation of -1 can be obtained. The instrumentation is simple and the method is efficient for the determination of lead in various water samples. 25 refs.; 7 figs.; 6 tabs

  5. Absorptive glass-mat separators for valve-regulated lead/acid batteries - thoughts on compression

    Energy Technology Data Exchange (ETDEWEB)

    Zguris, G.C. [Hovosorb Separators, Hollingsworth and Vose Co., West Groton, MA (United States)

    1997-07-01

    In the past few years valve-regulated lead/acid (VRLA) batteries have come under increased study. Their use has become more widespread, yet their expected life has not always been realized. This paper discusses some thoughts relating to the property of compression of the microglass separator and the impact of compression on VRLA battery life. Ideas are suggested for the design engineer to consider in selecting a battery separator. Additionally, several long-term battery separator tests are described. As more is learned about the complex interactions that are taking place in the VRLA recombination process, a greater appreciation is being given to the role of the separator. Today, battery designers can help improve expected battery performance by incorporating the latest information regarding battery separators, compression factors, and impact on life. (orig.)

  6. Estimation of lead, cadmium and nickel content by means of Atomic Absorption Spectroscopy in dry fruit bodies of some macromycetes growing in Poland. II.

    Directory of Open Access Journals (Sweden)

    Jan Grzybek

    2014-08-01

    Full Text Available The content of lead, cadmium, and nickel in dry fruit bodies of 34 species of macromyoetes collected in Poland from 72 natural babitats by means of Atomic Absorption Spectroscopy (AAS was estimated.

  7. Determining the arsenic, cadmium, lead, copper and chromium contents by atomic absorption spectrometry in Pangasius fillets from Vietnam.

    Science.gov (United States)

    Molognoni, Luciano; Vitali, Luciano; Ploêncio, Leandro As; Santos, Jacson N; Daguer, Heitor

    2016-07-01

    Pangasius is a fish produced on a large scale in Vietnam and exported to many countries. Since river contamination from human activities can affect the safety of this food, fish consumption can cause exposure to potentially toxic elements for humans. The aim of this study, therefore, was to assess arsenic, cadmium, lead, copper and chromium contents by atomic absorption spectrometry in Pangasius fillet produced in the provinces of Dong Thap and Can Tho (Vietnam) and exported to Brazil. The limits of detection were: arsenic 0.5443 µg kg(-1) , cadmium 0.0040 mg kg(-1) , chromium 0.0004 mg kg(-1) , copper 0.0037 mg kg(-1) and lead 0.0284 mg kg(-1) . Analysis of 20 samples showed results below the limit of detection for arsenic, chromium and lead, while copper average concentration was 0.0234 mg kg(-1) . Cadmium average concentration was 0.0547 mg kg(-1) , with no significant difference between the two regions studied. The samples of Pangasius had no detectable concentrations of arsenic, chromium, copper and lead, and do not represent a hazard to public health. However, cadmium analysis revealed non-compliant samples, demonstrating the importance of monitoring the quality of imported Pangasius fish. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  8. Effects of different soil remediation methods on inhibition of lead absorption and growth and quality of Dianthus superbus L.

    Science.gov (United States)

    Yang, Xiaoyu; Ma, Siyue; Li, Jianheng

    2017-12-01

    Heavy metal pollution in soil poses a serious threat to the growth of plants used in traditional Chinese medicine. Therefore, a pot experiment was conducted to study the effects of various soil remediation methods on the performance of Herba Dianthi (Dianthus superbus L.) grown on Pb-contaminated soil. The results show that inoculation of Herba Dianthi with arbuscular mycorrhizal fungi (AMF) led to a significant reduction in Pb uptake (P< 0.05), and increased root development and root-to-shoot ratio compared to untreated control plants, along with the highest content of active components. When planting with Trifolium repens, the reduction effect of Pb absorption was insignificant. Herba Dianthi showed improved growth and active ingredients, and the lowest Pb content, with AMF inoculation. The addition of EDTA decreased the growth of Herba Dianthi, but promoted the absorption of Pb. The inhibition of tumor cells was highest in E2. In conclusion, inoculation with AMF can ensure that plant lead content meets testing standards, helping to improve the quality of medicinal herbs.

  9. Graphene oxide sheets immobilized polystyrene for column preconcentration and sensitive determination of lead by flame atomic absorption spectrometry.

    Science.gov (United States)

    Islam, Aminul; Ahmad, Hilal; Zaidi, Noushi; Kumar, Suneel

    2014-08-13

    A novel solid-phase extractant was synthesized by coupling graphene oxide (GO) on chloromethylated polystyrene through an ethylenediamine spacer unit to develop a column method for the preconcentration/separation of lead prior to its determination by flame atomic absorption spectrometry. It was characterized by Fourier transform infrared spectroscopy, far-infrared spectroscopy, thermogravimetric analysis/differential thermal analysis, scanning electron microscopy, energy-dispersive spectrometry, and transmission electron microscopy. The abundant oxygen-containing surface functional groups form a strong complex with lead, resulting in higher sorption capacity (227.92 mg g(-1)) than other nanosorbents used for sorption studies of the column method. Using the column procedure here is an alternative to the direct use of GO, which restricts irreversible aggregation of GO and its escape into the ecosystem, making it an environmentally sustainable method. The column method was optimized by varying experimental variables such as pH, flow rate for sorption/desorption, and elution condition and was observed to exhibit a high preconcentration factor (400) with a low preconcentration limit (2.5 ppb) and a high degree of tolerance for matrix ions. The accuracy of the proposed method was verified by determining the Pb content in the standard reference materials and by recovery experiments. The method showed good precision with a relative standard deviation <5%. The proposed method was successfully applied for the determination of lead in tap water, electroplating wastewater, river water, and food samples after preconcentration.

  10. Standard test method for graphite furnace atomic absorption spectrometric determination of lead and cadmium extracted from ceramic foodware

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers procedures for using graphite furnace atomic absorption spectroscopy (GFAAS) to quantitatively determine lead and cadmium extracted by acetic acid at room temperature from the food-contact surface of foodware. The method is applicable to food-contact surfaces composed of silicate-based materials (earthenware, glazed ceramicware, decorated ceramicware, decorated glass, and lead crystal glass) and is capable of determining lead concentrations greater than 0.005 to 0.020 g/mL and cadmium concentrations greater than 0.0005 to 0.002 g/mL, depending on instrument design. 1.2 This test method also describes quality control procedures to check for contamination and matrix interference during GFAAS analyses and a specific sequence of analytical measurements that demonstrates proper instrument operation during the time period in which sample solutions are analyzed. 1.3 Cleaning and other contamination control procedures are described in this test method. Users may modify contamination cont...

  11. Determination of arsenic, antimony, bismuth, cadmium, copper, lead, molybdenum, silver and zinc in geological materials by atomic-absorption spectrometry

    Science.gov (United States)

    Viets, J.G.; O'Leary, R. M.; Clark, Robert J.

    1984-01-01

    Arsenic, antimony, bismuth, cadmium, copper, lead, molybdenum, silver and zinc are very useful elements in geochemical exploration. In the proposed method, geological samples are fused with potassium pyrosulphate and the fusate is dissolved in a solution of hydrochloric acid, ascorbic acid and potassium iodide. When this solution is shaken with a 10% V/V Aliquat 336 - isobutyl methyl ketone organic phase, the nine elements of interest are selectively partitioned in the organic phase. All nine elements can then be determined in the organic phase using flame atomic-absorption spectrometry. The method is rapid and allows the determination of Ag and Cd at levels down to 0.1 p.p.m., Cu, Mo, and Zn down to 0.5 p.p.m., Pb, Bi and Sb down to 1 p.p.m. and As down to 5 p.p.m. in geological materials.

  12. Arsenic exposure at low-to-moderate levels and skin lesions, arsenic metabolism, neurological functions, and biomarkers for respiratory and cardiovascular diseases: Review of recent findings from the Health Effects of Arsenic Longitudinal Study (HEALS) in Bangladesh

    International Nuclear Information System (INIS)

    Chen Yu; Parvez, Faruque; Gamble, Mary; Islam, Tariqul; Ahmed, Alauddin; Argos, Maria; Graziano, Joseph H.; Ahsan, Habibul

    2009-01-01

    The contamination of groundwater by arsenic in Bangladesh is a major public health concern affecting 35-75 million people. Although it is evident that high levels (> 300 μg/L) of arsenic exposure from drinking water are related to adverse health outcomes, health effects of arsenic exposure at low-to-moderate levels (10-300 μg/L) are not well understood. We established the Health Effects of Arsenic Longitudinal Study (HEALS) with more than 20,000 men and women in Araihazar, Bangladesh, to prospectively investigate the health effects of arsenic predominately at low-to-moderate levels (0.1 to 864 μg/L, mean 99 μg/L) of arsenic exposure. Findings to date suggest adverse effects of low-to-moderate levels of arsenic exposure on the risk of pre-malignant skin lesions, high blood pressure, neurological dysfunctions, and all-cause and chronic disease mortality. In addition, the data also indicate that the risk of skin lesion due to arsenic exposure is modifiable by nutritional factors, such as folate and selenium status, lifestyle factors, including cigarette smoking and body mass index, and genetic polymorphisms in genes related to arsenic metabolism. The analyses of biomarkers for respiratory and cardiovascular functions support that there may be adverse effects of arsenic on these outcomes and call for confirmation in large studies. A unique strength of the HEALS is the availability of outcome data collected prospectively and data on detailed individual-level arsenic exposure estimated using water, blood and repeated urine samples. Future prospective analyses of clinical endpoints and related host susceptibility will enhance our knowledge on the health effects of low-to-moderate levels of arsenic exposure, elucidate disease mechanisms, and give directions for prevention.

  13. [Studies on markers of exposure and early effect in areas with arsenic pollution: methods and results of the project SEpiAs. Epidemiological studies on population exposed to low-to-moderate arsenic concentration in drinking water].

    Science.gov (United States)

    Bustaffa, Elisa; Bianchi, Fabrizio

    2014-01-01

    Arsenic and its inorganic compounds are classified as human carcinogens. Several epidemiological studies conducted in areas of the world characterized by high arsenic concentration in drinking water, even up to 3,000 μg/l, report associations between arsenic exposure and skin, bladder, lung, liver and kidney cancer as well as cardiovascular diseases, diabetes and reproductive and developmental effects. Since general population is not exposed to these high arsenic concentrations in the last years attention focused on adverse health effects that low-to-moderate arsenic concentrations (0-150 μg/l) in drinking water could induce. The World Health Organization recommends a maximum limit of 10 μg/l for arsenic in drinking water. Almost all epidemiological studies conducted on populations exposed to low-to-moderate arsenic concentrations in drinking water are limited due to problems arising from both individual exposure assessment and low subjects number. The aim of the present review is to collect literature-based evidences regarding adverse health effects associated with exposure to low-to-moderate arsenic concentrations in drinking water (10-150 μg/l) in order to obtain a comprehensive picture of the health outcomes that such exposure can have on general population.

  14. Precise determination of the deuteron spin structure at low to moderate Q2 with CLAS and extraction of the neutron contribution

    Science.gov (United States)

    Guler, N.; Fersch, R. G.; Kuhn, S. E.; Bosted, P.; Griffioen, K. A.; Keith, C.; Minehart, R.; Prok, Y.; Adhikari, K. P.; Adikaram, D.; Amaryan, M. J.; Anderson, M. D.; Anefalos Pereira, S.; Avakian, H.; Ball, J.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Biselli, A.; Briscoe, W. J.; Brooks, W. K.; Bültmann, S.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Chandavar, S.; Charles, G.; Colaneri, L.; Cole, P. L.; Contalbrigo, M.; Crabb, D.; Crede, V.; D'Angelo, A.; Dashyan, N.; Deur, A.; Djalali, C.; Dodge, G. E.; Dupre, R.; Alaoui, A. El; El Fassi, L.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Filippi, A.; Fleming, J. A.; Forest, T. A.; Garillon, B.; Garçon, M.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Golovatch, E.; Gothe, R. W.; Guidal, M.; Guo, L.; Hafidi, K.; Hakobyan, H.; Harrison, N.; Hattawy, M.; Hicks, K.; Ho, D.; Holtrop, M.; Hughes, S. M.; Hyde, C. E.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jo, H. S.; Joo, K.; Joosten, S.; Keller, D.; Khandaker, M.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Kubarovsky, V.; Kuleshov, S. V.; Livingston, K.; Lu, H. Y.; Mayer, M.; MacGregor, I. J. D.; McKinnon, B.; Mirazita, M.; Mokeev, V.; Montgomery, R. A.; Movsisyan, A.; Munoz Camacho, C.; Nadel-Turonski, P.; Net, L. A.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Park, K.; Pasyuk, E.; Pisano, S.; Pogorelko, O.; Price, J. W.; Procureur, S.; Ripani, M.; Rizzo, A.; Rosner, G.; Rossi, P.; Roy, P.; Sabatié, F.; Salgado, C.; Schott, D.; Schumacher, R. A.; Seder, E.; Simonyan, A.; Skorodumina, Iu.; Sokhan, D.; Sparveris, N.; Strakovsky, I. I.; Strauch, S.; Sytnik, V.; Tian, Ye; Tkachenko, S.; Ungaro, M.; Voutier, E.; Walford, N. K.; Wei, X.; Weinstein, L. B.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zhao, Z. W.; Zonta, I.; CLAS Collaboration

    2015-11-01

    We present the final results for the deuteron spin structure functions obtained from the full data set collected in 2000-2001 with Jefferson Lab's continuous electron beam accelerator facility (CEBAF) using the CEBAF large acceptance spectrometer (CLAS). Polarized electrons with energies of 1.6, 2.5, 4.2, and 5.8 GeV were scattered from deuteron (15ND3 ) targets, dynamically polarized along the beam direction, and detected with CLAS. From the measured double-spin asymmetry, the virtual photon absorption asymmetry A1d and the polarized structure function g1d were extracted over a wide kinematic range (0.05 GeV2

  15. Preconcentration of lead using solidification of floating organic drop and its determination by electrothermal atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Mahmoud Chamsaz

    2013-07-01

    Full Text Available A simple microextraction method based on solidification of a floating organic drop (SFOD was developed for preconcentration of lead prior to its determination by electrothermal atomic absorption spectrometry (ETAAS. Ammonium pyrolidinedithiocarbamate (APDC was used as complexing agent, and the formed complex was extracted into a 20 μL of 1-undecanol. The extracted complex was diluted with ethanol and injected into a graphite furnace. An orthogonal array design (OAD with OA16 (45 matrix was employed to study the effects of different parameters such as pH, APDC concentration, stirring rate, sample solution temperature and the exposure time on the extraction efficiency. Under the optimized experimental conditions the limit of detection (based on 3 s and the enhancement factor were 0.058 μg L−1 and 113, respectively. The relative standard deviation (RSD for 8 replicate determinations of 1 μg L−1 of Pb was 8.8%. The developed method was validated by the analysis of certified reference materials and was successfully applied to the determination of lead in water and infant formula base powder samples.

  16. Cadmium and lead determination in foods by beam injection flame furnace atomic absorption spectrometry after ultrasound-assisted sample preparation

    International Nuclear Information System (INIS)

    Aleixo, Poliana Carolina; Junior, Dario Santos; Tomazelli, Andrea Cristina; Rufini, Iolanda A.; Berndt, Harald; Krug, Francisco Jose

    2004-01-01

    A simple method for cadmium and lead determination in foods by beam injection flame furnace atomic absorption spectrometry (BIFF-AAS) was proposed. Food slurries were prepared by transferring an exact amount of cryogenic-ground homogenized material (50-100 mg) to centrifuge tubes, followed by addition of 5 ml (up to 2.8 mol l -1 ) nitric acid solution and sonication in an ultrasonic bath during 5-10 min. Thereafter, slurries were diluted with water to 10 ml, centrifuged during 5 min at 5400 rpm and 400 μl aliquot of the supernatant was analyzed by BIFF-AAS. The detection limits based on peak height measurements were 0.03 μg g -1 Cd and 1.6 μg g -1 Pb for 2% (m/v) slurry (200 mg/10 ml). For method validation, the certified reference materials Pig Kidney (BCR 186) and Rice Flour (NIES 10) were used. Quantitative cadmium and lead recoveries were obtained and no statistical differences were found at 95% level by applying the t-test

  17. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    International Nuclear Information System (INIS)

    Andrada, Daniel; Pinto, Frederico G.; Magalhaes, Cristina Goncalves; Nunes, Berta R.; Silva, Jose Bento Borba da; Franco, Milton B.

    2006-01-01

    The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ETAAS). Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 μL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO 3 1% v/v and 0.02% v/v of cetyl trimethyl ammonium chloride (CTAC) were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 μL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 μg), the best pyrolysis and atomization temperatures were 900 and 1600 deg C, respectively, with a characteristic mass of 12 pg (recommended of 10 pg), with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence) for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh) and between 93.9 and 105.2% (Zr+Rh). In both recovery studies, the relative standard deviation (n=3) was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r 2 higher than 0.99. The limits of detection were 0.7 μg L -1 for serum samples, with Zr+Rh permanent, and 1.0 μg L -1 for urine with iridium permanent. (author)

  18. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    Directory of Open Access Journals (Sweden)

    Andrada Daniel

    2006-01-01

    Full Text Available The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ET AAS. Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 µL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO3 1% v/v and 0.02% v/v of cetil trimethyl ammonium chloride (CTAC were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 µL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 µg, the best pyrolysis and atomization temperatures were 900 and 1600 ºC, respectively, with a characteristic mass of 12 pg (recommended of 10 pg, with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh and between 93.9 and 105.2% (Zr+Rh. In both recovery studies, the relative standard deviation (n=3 was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r² higher than 0.99. The limits of detection were 0.7 µg L-1 for serum samples, with Zr+Rh permanent, and 1.0 µg L-1 for urine with iridium permanent.

  19. Heat transfer measurements on an incidence-tolerant low pressure turbine blade in a high speed linear cascade at low to moderate Reynolds numbers

    Science.gov (United States)

    Moualeu, Leolein Patrick Gouemeni

    heat transfer approach is the method used to obtain knowledge of the state of the boundary layer on the surface of the blade. Pressure and temperature distributions are acquired for Reynolds numbers of 50,000, 66,000, 228,000, and 568,000 at an exit Mach number of 0.72, and Reynolds numbers of 228,000, and 568,000 at an exit Mach number of 0.35. These experimental flow conditions are conducted at different flow inlet angles of 40°, 34.2°, 28°, 18°, 8°, -2.6°, -12°, and -17°, and at two free-stream turbulence levels. Results of the analyses performed show that as the incidence angle decreases, a region of laminar separation bubble forms on the pressure surface and grows toward the trailing-edge. It is also noted that the position of the leading-edge moves as the incidence angle varies. A transitional flow is observed on both the pressure and suction surfaces, mainly at the two highest incidence angles, for the high turbulence case. This investigation also reveals that the Stanton number increases as the mainstream turbulence increases, and that the Stanton number at the leading-edge increases as the Reynolds number decreases, as it is documented in the literature.

  20. Preconcentration and determination of zinc and lead ions by a combination of cloud point extraction and flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tavallali, H. [Chemistry Department, Payamenore University, Shiraz (Iran); Shokrollahi, A.; Zahedi, M. [Chemistry Department, Yasouj University, Yasouj (Iran); Niknam, K. [Chemistry Department, Persian Gulf University, Bushehr (Iran); Soylak, M. [Chemistry Department, University of Erciyes, Kayseri (Turkey); Ghaedi, M.

    2009-04-15

    The phase-separation phenomenon of non-ionic surfactants occurring in aqueous solution was used for the extraction of lead(II) and zinc(II). After complexation with 3-[(4-bromophenyl) (1-H-inden-3-yl)methyl]-1 H-indene (BPIMI), the analytes were quantitatively extracted to a phase rich in Triton X-114 after centrifugation. Methanol acidified with 1 mol/L HNO{sub 3} was added to the surfactant rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). The concentration of bis((1H-benzo [d] imidazol-2yl)ethyl)sulfane, Triton X-114, pH and amount of surfactant were all optimized. Detection limits (3 SDb/m) of 2.5 and 1.6 ng/mL for Pb{sup 2+} and Zn{sup 2+} along with preconcentration factors of 30 and an enrichment factor of 32 and 48 for Pb{sup 2+}and Zn {sup 2+} ions were obtained, respectively. The proposed cloud point extraction was been successfully applied for the determination of these ions in real samples with complicated matrices such as food and soil samples, with high efficiency. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  1. Coacervative extraction of trace lead from natural waters prior to its determination by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hagarová, Ingrid, E-mail: hagarova@fns.uniba.sk; Bujdoš, Marek; Matúš, Peter; Kubová, Jana

    2013-10-01

    In this work, a relatively simple and sensitive method for separation/preconcentration of trace lead from natural waters prior to its determination by electrothermal atomic absorption spectrometry has been proposed. The method is based on the extraction of Pb–dithizone chelate with coacervates made up of lauric acid in the presence of potassium ions and methanol. Several important factors affecting extraction efficiency such as pH, concentration of lauric acid and dithizone, ionic strength, incubation and centrifugation time were investigated and optimized. After separation of aqueous bulk solution from surfactant-rich phase, the final extract was redissolved by using 500 μl of methanol acidified with 0.2 mol l{sup −1} HNO{sub 3}. Under the optimized conditions (using initial sample volume of 10 ml), enrichment factor of 17.0, detection limit of 0.12 μg l{sup −1}, quantification limit of 0.38 μg l{sup −1}, relative standard deviation of 4.2% (for 2 μg l{sup −1} of Pb; n = 26), linearity of the calibration graph in the range of 0.5–4.0 μg l{sup −1} (with correlation coefficient better than 0.995) were achieved. The method was validated by the analysis of certified reference material (TMDA-61). Extraction recoveries for the CRM, spiked model solutions and spiked natural water samples were in the range of 91–96%. Finally, the method was applied to the separation/preconcentration and determination of trace lead in natural waters. - Highlights: • The potential of coacervates for the extraction of metal ions is examined. • No difficulties in coupling of ETAAS with the proposed CAE are observed. • Achieved preconcentration factor results in enhanced sensitivity. • Analytical performance is confirmed by the reliable determination of trace Pb. • The proposed CAE is ecofriendly and efficient.

  2. A pilot study examining the effects of low-volume high-intensity interval training and continuous low to moderate intensity training on quality of life, functional capacity and cardiovascular risk factors in cancer survivors.

    Science.gov (United States)

    Toohey, Kellie; Pumpa, Kate L; Arnolda, Leonard; Cooke, Julie; Yip, Desmond; Craft, Paul S; Semple, Stuart

    2016-01-01

    The aim of this study was to evaluate the effects of low-volume high-intensity interval training and continuous low to moderate intensity training on quality of life, functional capacity and cardiovascular disease risk factors in cancer survivors. Cancer survivors within 24 months post-diagnosis were randomly assigned into the low-volume high-intensity interval training group ( n  = 8) or the continuous low to moderate intensity training group ( n  = 8) group for 36 sessions (12 weeks) of supervised exercise. The low-volume high-intensity interval training (LVHIIT) group performed 7 × 30 s intervals (≥85% maximal heart rate) and the continuous low to moderate intensity training (CLMIT) group performed continuous aerobic training for 20 min (≤55% maximal heart rate) on a stationary bike or treadmill. Significant improvements (time) were observed for 13 of the 23 dependent variables (ES 0.05-0.61, p  ≤ 0.05). An interaction effect was observed for six minute walk test (18.53% [32.43-4.63] ES 0.50, p  ≤ 0.01) with the LVHIIT group demonstrating greater improvements. These preliminary findings suggest that both interventions can induce improvements in quality of life, functional capacity and selected cardiovascular disease risk factors. The LVHIIT program was well tolerated by the participants and our results suggest that LVHIIT is the preferred modality to improve fitness (6MWT); it remains to be seen which intervention elicits the most clinically relevant outcomes for patients. A larger sample size with a control group is required to confirm the significance of these findings.

  3. A novel lead imprinted polymer as the selective solid phase for extraction and trace detection of lead ions by flame atomic absorption spectrophotometry: Synthesis, characterization and analytical application

    Directory of Open Access Journals (Sweden)

    Homeira Ebrahimzadeh

    2017-05-01

    Full Text Available A novel ion imprinted polymer as the selective solid phase combined with flame atomic absorption spectrometry (FAAS was applied for preconcentration and determination of lead in real samples. In the first step, Pb(II-IIP was synthesized by copolymerization of 2-vinyl pyridine as the functional monomer, ethylene glycol dimethacrylate as the cross-linker, 2,2-azobisisobutyronitrile as the initiator that imprinted with Pb(II as the template ion, 2-amino pyridine as the ligand. Subsequently, the imprinted Pb(II was completely removed by leaching the dried and powdered imprinted polymer with HCl (2 mol L−1. This polymer was characterized by Fourier Transform Infrared (FT-IR spectrometer. The effect of different variables on the extraction efficiency such as type and volume of eluent for extraction, solution’s pH for adsorption, sorption and desorption times was evaluated. Under the optimum conditions: type of eluent, HCl (2 mol L−1; volume of eluent, 5 mL; solution’s pH for sorption, 5; sorption time, 90 min; desorption time, 125 min and breakthrough volume of 750 mL were obtained. Preconcentration factor of the method was about 150. The limit of detection was obtained 0.75 μg L−1 and a dynamic linear range (DLR of 3–150 μg L−1 was found. The maximum sorption retention capacity of Pb(II ions on the imprinted polymer was 85.6 mg g−1. The prepared ion-imprinted polymer particles have an increased selectivity toward Pb(II ions over a range of competing metal ions with the same charge and similar ionic radius. Performance of the present method was evaluated for extraction and determination of Pb(II in water samples at microgram per liter concentration and satisfactory results were obtained (RSD = 2.7%.

  4. Molecular evidence and physiological characterization of iron absorption in isolated enterocytes of rainbow trout (Oncorhynchus mykiss): Implications for dietary cadmium and lead absorption

    International Nuclear Information System (INIS)

    Kwong, Raymond W.M.; Andres, Jose A.; Niyogi, Som

    2010-01-01

    Recent studies suggested the probable involvement of an apical iron (Fe 2+ ) transporter, the divalent metal transporter-1 (DMT1), in the uptake of several divalent metals in fish. The present study examined the gastrointestinal expression of the DMT1 gene, and investigated the kinetics of Fe 2+ uptake and its interactions with cadmium and lead in isolated enterocytes of freshwater rainbow trout (Oncorhynchus mykiss). The expressions of two DMT1 isoforms (Nramp-β and -γ) were recorded along the entire gastrointestinal tract of fish as well as in the enterocytes. Fe 2+ uptake in isolated enterocytes was saturable and sensitive to the proton gradient and membrane potential, suggesting DMT1-mediated transport. Both cadmium and lead inhibited Fe 2+ uptake in isolated enterocytes in a concentration-dependent manner, and lead appeared to be a stronger inhibitor than cadmium. The kinetic characterization of Fe 2+ uptake revealed that the apparent affinity of uptake was significantly decreased (increased K m ) in the presence of either cadmium or lead, whereas the maximum uptake rate (J max ) remained unchanged-indicating that the interaction between Fe 2+ and cadmium or lead is competitive in nature. Overall, our study suggests that the uptake of dietary cadmium and lead may occur via the iron-transporting pathway in fish.

  5. Molecular evidence and physiological characterization of iron absorption in isolated enterocytes of rainbow trout (Oncorhynchus mykiss): Implications for dietary cadmium and lead absorption

    Energy Technology Data Exchange (ETDEWEB)

    Kwong, Raymond W.M. [Toxicology Centre, University of Saskatchewan, Saskatoon, SK., S7N 5B3 (Canada); Andres, Jose A. [Department of Biology, University of Saskatchewan, Saskatoon, SK., S7N 5E2 (Canada); Niyogi, Som, E-mail: som.niyogi@usask.ca [Department of Biology, University of Saskatchewan, Saskatoon, SK., S7N 5E2 (Canada)

    2010-09-01

    Recent studies suggested the probable involvement of an apical iron (Fe{sup 2+}) transporter, the divalent metal transporter-1 (DMT1), in the uptake of several divalent metals in fish. The present study examined the gastrointestinal expression of the DMT1 gene, and investigated the kinetics of Fe{sup 2+} uptake and its interactions with cadmium and lead in isolated enterocytes of freshwater rainbow trout (Oncorhynchus mykiss). The expressions of two DMT1 isoforms (Nramp-{beta} and -{gamma}) were recorded along the entire gastrointestinal tract of fish as well as in the enterocytes. Fe{sup 2+} uptake in isolated enterocytes was saturable and sensitive to the proton gradient and membrane potential, suggesting DMT1-mediated transport. Both cadmium and lead inhibited Fe{sup 2+} uptake in isolated enterocytes in a concentration-dependent manner, and lead appeared to be a stronger inhibitor than cadmium. The kinetic characterization of Fe{sup 2+} uptake revealed that the apparent affinity of uptake was significantly decreased (increased K{sub m}) in the presence of either cadmium or lead, whereas the maximum uptake rate (J{sub max}) remained unchanged-indicating that the interaction between Fe{sup 2+} and cadmium or lead is competitive in nature. Overall, our study suggests that the uptake of dietary cadmium and lead may occur via the iron-transporting pathway in fish.

  6. Lead and cadmium in human teeth from Jordan by atomic absorption spectrometry: Some factors influencing their concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Alomary, A. [Department of Chemistry, Yarmouk University, Irbid (Jordan)]. E-mail: ahmedalomary1000@hotmail.com; Al-Momani, I.F. [Department of Chemistry, Yarmouk University, Irbid (Jordan); Massadeh, A.M. [Department of Medicinal Chemistry and Pharmacognosy, Faculty of Pharmacy, Jordan University of Science and Technology, Irbid (Jordan)

    2006-10-01

    The aim of this study was to measure the concentrations of lead (Pb) and cadmium (Cd) in human teeth and to investigate the affecting factors. Teeth samples (n = 268) were collected from people living in different cities in Jordan including Amman, Zarqa, Al-Mafraq and Irbid and analyzed for Pb and Cd using atomic absorption spectrometry (AAS). A questionnaire was used to gather information on each person, such as age, sex, place where the patient lives, smoking, presence of amalgam fillings inside the mouth, and whether the patient uses toothpaste or not. The mean concentrations of Pb and Cd were 28.91 {mu}g/g and 0.44 {mu}g/g, respectively. The results indicate that there is a clear relation between Pb and Cd concentrations and the presence of amalgam fillings, smoking, and place of living. Pb was sex-dependent, whereas Cd was not. Our results show that Pb and Cd concentrations in samples obtained from Al-Mafraq and Irbid are higher than those obtained from Amman and Zarqa. Pb was highest in Mafraq, whereas Cd was highest in Irbid. The Pb and Cd concentrations in teeth from smokers (means: Pb = 31.89 {mu}g/g, Cd = 0.49 {mu}g/g) were significantly higher than those from nonsmokers (means: Pb = 24.07 {mu}g/g, Cd = 0.37 {mu}g/g). Pb and Cd concentrations in teeth of patients with amalgam fillings (means: Pb = 31.02 {mu}g/g and Cd = 0.52 {mu}g/g) were significantly higher than those from patients without amalgam fillings (means: Pb = 26.87 {mu}g/g and Cd = 0.41 {mu}g/g). Our results show that brushing the teeth daily with toothpaste does not significantly decrease the concentration of both Pb and Cd. The mean concentrations of Pb and Cd do not vary significantly between the ages 20-30, 31-40, and 41-50, but both increased rapidly at age 51-60.

  7. Lead and cadmium in human teeth from Jordan by atomic absorption spectrometry: Some factors influencing their concentrations

    International Nuclear Information System (INIS)

    Alomary, A.; Al-Momani, I.F.; Massadeh, A.M.

    2006-01-01

    The aim of this study was to measure the concentrations of lead (Pb) and cadmium (Cd) in human teeth and to investigate the affecting factors. Teeth samples (n = 268) were collected from people living in different cities in Jordan including Amman, Zarqa, Al-Mafraq and Irbid and analyzed for Pb and Cd using atomic absorption spectrometry (AAS). A questionnaire was used to gather information on each person, such as age, sex, place where the patient lives, smoking, presence of amalgam fillings inside the mouth, and whether the patient uses toothpaste or not. The mean concentrations of Pb and Cd were 28.91 μg/g and 0.44 μg/g, respectively. The results indicate that there is a clear relation between Pb and Cd concentrations and the presence of amalgam fillings, smoking, and place of living. Pb was sex-dependent, whereas Cd was not. Our results show that Pb and Cd concentrations in samples obtained from Al-Mafraq and Irbid are higher than those obtained from Amman and Zarqa. Pb was highest in Mafraq, whereas Cd was highest in Irbid. The Pb and Cd concentrations in teeth from smokers (means: Pb = 31.89 μg/g, Cd = 0.49 μg/g) were significantly higher than those from nonsmokers (means: Pb = 24.07 μg/g, Cd = 0.37 μg/g). Pb and Cd concentrations in teeth of patients with amalgam fillings (means: Pb = 31.02 μg/g and Cd = 0.52 μg/g) were significantly higher than those from patients without amalgam fillings (means: Pb = 26.87 μg/g and Cd = 0.41 μg/g). Our results show that brushing the teeth daily with toothpaste does not significantly decrease the concentration of both Pb and Cd. The mean concentrations of Pb and Cd do not vary significantly between the ages 20-30, 31-40, and 41-50, but both increased rapidly at age 51-60

  8. Organic palladium and palladium-magnesium chemical modifiers in direct determination of lead in fractions from distillation of crude oil by electrothermal atomic absorption analysis

    Science.gov (United States)

    Kowalewska, Zofia; Bulska, Ewa; Hulanicki, Adam

    1999-05-01

    Platinum reforming catalysts are easily poisoned by increased levels of lead, therefore a sensitive atomic absorption spectrometric procedure for lead determination in fractions from crude oil distillation was developed. Lead was present in organic form in the samples analysed therefore the behaviour of various lead compounds (Pb-alkylarylsulphonate, Pb-4-cyclohexanobutyrate, tetraethyllead, Pb in fuel oil) was studied. The best procedure for the determination of lead in different petroleum products, including those containing asphaltenes includes a pretreatment with iodine and methyltrioctylammonium chloride, followed by the use of an organic Pd-Mg modifier. Under these conditions an effective matrix removal is possible at a pyrolysis temperature up to approximately 1100°C and the behaviour of lead present in different forms is unified. The characteristic mass is 11-12 pg Pb, corresponding to a detection limit of 0.25 ng g -1 for 20 μl sample solution. This can be lowered by multiple injection.

  9. Determination of lead associated with airborne particulate matter by flame atomic absorption and wave-length dispersive x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Talebi, S.M.

    1997-01-01

    The lead content of airborne particulate matter was determined by flame atomic absorption spectrometry (FAAS) following digestion with a mixture of nitric acid and hydrogen peroxide and also by wave-length dispersive x-ray fluorescence (WDXRF). The extraction procedure was checked by analyzing a standard reference material of airborne particulate matter (NIST, SRM -1648). It was concluded that lead can quantitatively (98%) be extracted from airborne particulate matter by the leaching process. A five-stage sequential extraction was performed to assess the potential mobility of lead associated with airborne particulate matter. Comparison of the airborne particulate lead measured by WDXRF to that measured by FAAS showed good agreement. The WDXRF method requires no time-consuming sample preparation or use of environmentally unfriendly solvents. The technique is suggested for direct determination of lead in airborne particulate matter in air pollution studies. (author)

  10. Direct determination of beryllium, cadmium, lithium, lead and silver in thorium nitrate solution by electrothermal atomization atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Thulasidas, S.K.; Kulkarni, M.J.; Porwal, N.K.; Page, A.G.; Sastry, M.D.

    1988-01-01

    An electrothermal atomization atomic absorption spectrometric (ET-AAS) method is developed for the direct determination of Ag, Be, Cd, Li and Pb in thorium nitrate solution. The method offers detection of sub-nanogram amounts of these analytes in 100-microgram thorium samples with a precision of around 10%. A number of spiked samples and pre-analyzed ThO 2 samples have been analyzed to evaluate the performance of the analytical methods developed here

  11. Coupling continuous ultrasound-assisted extraction, preconcentration and flame atomic absorption spectrometric detection for the determination of cadmium and lead in mussel samples

    International Nuclear Information System (INIS)

    Yebra-Biurrun, M.C.; Cancela-Perez, S.; Moreno-Cid-Barinaga, A.

    2005-01-01

    Continuous ultrasound-assisted extraction has been coupled with preconcentration and flame atomic absorption spectrometry for the determination of cadmium and lead in mussel samples. Experimental designs were used for the optimisation of the leaching and preconcentration steps. The use of diluted nitric acid as extractant in the continuous mode at a flow rate of 3.5 ml min -1 and room temperature was sufficient for quantitative extraction of these trace metals. A minicolumn containing a chelating resin (Chelite P, with aminomethylphosphoric acid groups) was proved as an excellent material for the quantitative preconcentration of cadmium and lead prior to their flame atomic absorption detection. A flow injection manifold was used as interface for coupling the three analytical steps, which allowed the automation of the whole analytical process. A good precision of the whole procedure (2.0 and 2.3%), high enrichment factors (20.5 and 11.8) and a detection limit of 0.011 and 0.25 μg g -1 for cadmium and lead, respectively, were obtained for 80 mg of sample. The sample throughputs were ca. 16 and 14 samples h -1 for cadmium and lead, respectively. The accuracy of the analytical procedures was verified by using a standard reference material (BCR 278-R, mussel tissue) and the results were in good agreement with the certified values. The method was successfully applied to the determination of trace amounts of cadmium and lead in mussel samples from the coast of Galicia (NW, Spain)

  12. Determination of lead and cadmium in hen eggs by graphite france electrothermal atomic absorption spectrometry and estimation of the daily intake

    International Nuclear Information System (INIS)

    Siddiqui, I.; Nizami, S.S.

    2012-01-01

    A total of 54 hen eggs were procured from nine poultry farms of Sindh, Pakistan in different batches to determine lead and cadmium toxicity. The quantitative analysis of lead (Pb) and cadmium (Cd) in egg samples were performed on electrothermal atomic absorption spectrometer (ETAAS), with Zeeman effects background correction. Lead concentrations in hen egg samples ranged from 0.027 to 1.056 micro g/g with a mean value of 0.283 micro g/g +- 0.86, whereas cadmium concentrations ranged from 0.001 to 0.012 micro g/g with a mean value of 0.003 micro g/g +-0.002. Lead concentrations exceeded the normal levels of 0.020 but cadmium was found lower than the normal levels of 0.005 micro g/g. (author)

  13. Preconcentration, Separation and Determination of lead(II) with Methyl Thymol Blue Adsorbed on Activated Carbon Using Flame Atomic Absorption Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ensafi, Ali A.; Ghaderi, Ali R. [Isfahan University of Technology, Isfahan (Iran, Islamic Republic of)

    2008-02-15

    An on-line system for preconcentration and separation of lead(II) is presented. The method is based on the complex formation of Pb(II) with adsorbed Methyl thymol blue on activated carbon. The conditions of preparing the solid phase reagent and of quantitative recovery of Pb(II) from diluted solutions, such as acidity of aqueous phase, solid phase capacity, and flow variables were studied as well as effect of potential interfering ions. After preconcentration step, the metal ions are eluted automatically by 5 ml of 0.5 M HNO{sub 3} solution and the lead ions content was determined by flame atomic absorption spectrometry. Under the optimum conditions, the lead ions in aqueous samples were separated and preconcentrated about 1000-fold by the column. The detection limit was 0.001 μg mL{sup -1}. Lead has been determined in river and tap water samples, with recovery of 98 to 102%.

  14. Copper Deficiency Leads to Anemia, Duodenal Hypoxia, Upregulation of HIF-2α and Altered Expression of Iron Absorption Genes in Mice

    Science.gov (United States)

    Matak, Pavle; Zumerle, Sara; Mastrogiannaki, Maria; El Balkhi, Souleiman; Delga, Stephanie; Mathieu, Jacques R. R.; Canonne-Hergaux, François; Poupon, Joel; Sharp, Paul A.; Vaulont, Sophie; Peyssonnaux, Carole

    2013-01-01

    Iron and copper are essential trace metals, actively absorbed from the proximal gut in a regulated fashion. Depletion of either metal can lead to anemia. In the gut, copper deficiency can affect iron absorption through modulating the activity of hephaestin - a multi-copper oxidase required for optimal iron export from enterocytes. How systemic copper status regulates iron absorption is unknown. Mice were subjected to a nutritional copper deficiency-induced anemia regime from birth and injected with copper sulphate intraperitoneally to correct the anemia. Copper deficiency resulted in anemia, increased duodenal hypoxia and Hypoxia inducible factor 2α (HIF-2α) levels, a regulator of iron absorption. HIF-2α upregulation in copper deficiency appeared to be independent of duodenal iron or copper levels and correlated with the expression of iron transporters (Ferroportin - Fpn, Divalent Metal transporter – Dmt1) and ferric reductase – Dcytb. Alleviation of copper-dependent anemia with intraperitoneal copper injection resulted in down regulation of HIF-2α-regulated iron absorption genes in the gut. Our work identifies HIF-2α as an important regulator of iron transport machinery in copper deficiency. PMID:23555700

  15. Combination of flame atomic absorption spectrometry with ligandless-dispersive liquid- liquid microextraction for preconcentration and determination of trace amount of lead in water samples

    Directory of Open Access Journals (Sweden)

    Y.M. Baghelani

    2013-05-01

    Full Text Available A new ligandless-dispersive liquid–liquid microextraction method has been developed for the separation and flame atomic absorption spectrometry determination of trace amount of lead(II ion. In the proposed approach 1,2-dicholorobenzene and ethanol were used as extraction and dispersive solvents. Factors influencing the extraction efficiency of lead, including the extraction and dispersive solvent type and volume, pH of sample solution, concentration of chloride and extraction time were studied. Under the optimal conditions, the calibration curve was linear in the range of 7.0–6000 ng mL−1 of lead with R2 = 0.9992 (n = 10 and detection limit based on three times the standard deviation of the blank (3Sb was 0.5 ng mL−1 in original solution. The relative standard deviation for eight replicate determinations of 1.0 mg mL-1 lead was ±1.6%. The high efficiency of dispersive liquid-liquid microextraction to carry out the determination of trace amounts of lead in complex matrices was demonstrated. The proposed method has been applied for determination of trace amounts of lead in water samples and satisfactory results were obtained. The accuracy was checked by analyzing a certified reference material from the National Institute of Standard and Technology, Trace elements in water (NIST CRM 1643e.

  16. Analyzing Lead Content in Ancient Bronze Coins by Flame Atomic Absorption Spectroscopy: An Archaeometry Laboratory with Nonscience Majors

    Science.gov (United States)

    Donais, Mary Kate; Whissel, Greg; Dumas, Ashley; Golden, Kathleen

    2009-01-01

    A unique, interdisciplinary collaboration between chemistry and classics has led to the development of an experiment for nonscience majors. This instrumental analysis experiment was designed for use in an archaeology course to quantify the amount of lead in ancient bronze coins. The coins were corroded beyond visual identification, so provenance…

  17. Parity-Forbidden Transitions and Their Impact on the Optical Absorption Properties of Lead-Free Metal Halide Perovskites and Double Perovskites.

    Science.gov (United States)

    Meng, Weiwei; Wang, Xiaoming; Xiao, Zewen; Wang, Jianbo; Mitzi, David B; Yan, Yanfa

    2017-07-06

    Using density functional theory calculations, we analyze the optical absorption properties of lead (Pb)-free metal halide perovskites (AB 2+ X 3 ) and double perovskites (A 2 B + B 3+ X 6 ) (A = Cs or monovalent organic ion, B 2+ = non-Pb divalent metal, B + = monovalent metal, B 3+ = trivalent metal, X = halogen). We show that if B 2+ is not Sn or Ge, Pb-free metal halide perovskites exhibit poor optical absorptions because of their indirect band gap nature. Among the nine possible types of Pb-free metal halide double perovskites, six have direct band gaps. Of these six types, four show inversion symmetry-induced parity-forbidden or weak transitions between band edges, making them not ideal for thin-film solar cell applications. Only one type of Pb-free double perovskite shows optical absorption and electronic properties suitable for solar cell applications, namely, those with B + = In, Tl and B 3+ = Sb, Bi. Our results provide important insights for designing new metal halide perovskites and double perovskites for optoelectronic applications.

  18. Electrothermal atomic absorption spectrometric determination of cobalt, copper, lead and nickel traces in aragonite following flotation and extraction separation.

    Science.gov (United States)

    Zendelovska, D; Pavlovska, G; Cundeva, K; Stafilov, T

    2001-03-30

    A method of determination of Co, Cu, Pb and Ni in nanogram quantities from aragonite is presented. Flotation and extraction of Co, Cu, Pb and Ni is suggested as methods for elimination matrix interferences of calcium. The method of flotation is performed by iron(III) hexamethylenedithiocarbamate, Fe(HMDTC)(3), as a colloid precipitate collector. The liquid-liquid extraction of Co, Cu, Pb and Ni is carried out by sodium diethyldithiocarbamate, NaDDTC, as complexing reagent into methylisobutyl ketone, MIBK. The electrothermal atomic absorption spectrometry (ETAAS) is used for determination of analytes. The detection limits of ETAAS followed by flotation are: 7.8 ng.g(-1) for Co, 17.1 ng.g(-1) for Cu, 7.2 ng.g(-1) for Pb and 9.0 mug.g(-1) for Ni. The detection limits of ETAAS followed by extraction are found to be: 12.0 ng.g(-1) for Co, 51.0 ng.g(-1) for Cu, 24.0 ng.g(-1) for Pb and 21.0 ng.g(-1) for Ni.

  19. Simultaneous preconcentration of cadmium and lead in water samples with silica gel and determination by flame atomic absorption spectrometry.

    Science.gov (United States)

    Xu, Hongbo; Wu, Yun; Wang, Jian; Shang, Xuewei; Jiang, Xiaojun

    2013-12-01

    A new method that utilizes pretreated silica gel as an adsorbent has been developed for simultaneous preconcentration of trace Cd(II) and Pb(II) prior to the measurement by flame atomic absorption spectrometry. The effects of pH, the shaking time, the elution condition and the coexisting ions on the separation/preconcentration conditions of analytes were investigated. Under optimized conditions, the static adsorption capacity of Cd(II) and Pb(II) were 45.5 and 27.1mg/g, the relative standard deviations were 3.2% and 1.7% (for n = 11), and the limits of detection obtained were 4.25 and 0.60 ng/mL, respectively. The method was validated by analyzing the certified reference materials GBW 07304a (stream sediment) and successfully applied to the analysis of various treated wastewater samples with satisfactory results. Copyright © 2013 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  20. Mental health in low-to-moderate risk preterm, low birth weight, and small for gestational age children at 4 to 5 years: the role of early maternal parenting.

    Science.gov (United States)

    Westrupp, Elizabeth M; Mensah, Fiona K; Giallo, Rebecca; Cooklin, Amanda; Nicholson, Jan M

    2012-03-01

    The majority of children born preterm, with low birth weight, or small for gestational age are born with low-to-moderate risk (LTM), yet most research focuses on the high-risk group. Little is known about whether children with LTM perinatal risk are at greater risk for mental health problems, or what the role of early maternal parenting is in determining these outcomes. Longitudinal data were from a large nationally representative Australian cohort of 5,000 children, aged 0 to 1, 2 to 3, and 4 to 5 years of age. Participants were 354 children with LTM perinatal risk born at 33 to 36 weeks, with birth weight 1,501 to 2,499 grams, or born between the first and 10th percentiles for gestational age; and 2,461 children in the normal birth weight, term comparison group. Child mental health was measured by mother-report on the Strengths and Difficulties Questionnaire (SDQ). Parenting irritability, warmth, self-efficacy, maternal separation anxiety, and overprotective parenting were measured when children were 0 to 1 and 2 to 3 years of age. Parents in the LTM perinatal risk group were more likely to experience parenting difficulties on one of eight parenting measures (irritable parenting at age 0-1 year) when adjusting for socio-demographic differences (odds ratio = 1.43; 95% confidence interval = 1.05, 1.95, p parenting, pathway to psychological risk in children born with LTM perinatal risk. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  1. Dual antiplatelet therapy versus oral anticoagulation plus dual antiplatelet therapy in patients with atrial fibrillation and low-to-moderate thromboembolic risk undergoing coronary stenting: design of the MUSICA-2 randomized trial.

    Science.gov (United States)

    Sambola, Antonia; Montoro, J Bruno; Del Blanco, Bruno García; Llavero, Nadia; Barrabés, José A; Alfonso, Fernando; Bueno, Héctor; Cequier, Angel; Serra, Antonio; Zueco, Javier; Sabaté, Manel; Rodríguez-Leor, Oriol; García-Dorado, David

    2013-10-01

    Oral anticoagulation (OAC) is the recommended therapy for patients with atrial fibrillation (AF) because it reduces the risk of stroke and other thromboembolic events. Dual antiplatelet therapy (DAPT) is required after percutaneous coronary intervention and stenting (PCI-S). In patients with AF requiring PCI-S, the association of DAPT and OAC carries an increased risk of bleeding, whereas OAC therapy or DAPT alone may not protect against the risk of developing new ischemic or thromboembolic events. The MUSICA-2 study will test the hypothesis that DAPT compared with triple therapy (TT) in patients with nonvalvular AF at low-to-moderate risk of stroke (CHADS2 score ≤2) after PCI-S reduces the risk of bleeding and is not inferior to TT for preventing thromboembolic complications. The MUSICA-2 is a multicenter, open-label randomized trial that will compare TT with DAPT in patients with AF and CHADS2 score ≤2 undergoing PCI-S. The primary end point is the incidence of stroke or any systemic embolism or major adverse cardiac events: death, myocardial infarction, stent thrombosis, or target vessel revascularization at 1 year of PCI-S. The secondary end point is the combination of any cardiovascular event with major or minor bleeding at 1 year of PCI-S. The calculated sample size is 304 patients. The MUSICA-2 will attempt to determine the most effective and safe treatment in patients with nonvalvular AF and CHADS2 score ≤2 after PCI-S. Restricting TT for AF patients at high risk for stroke may reduce the incidence of bleeding without increasing the risk of thromboembolic complications. © 2013.

  2. Microdetermination of lead, cadmium, zinc and tin in biological and related materials by atomic absorption spectrometry after mineralisation and extraction

    International Nuclear Information System (INIS)

    Boiteau, H.L.; Metayer, C.

    1978-01-01

    Two technics permitting to determine either lead, cadmium and zinc, or tin in any biological material (blood, urines, organs, alimentary products of animal or vegetable origin) are described. Every operation (mineralisation and extraction) is made in the same tube and technics, conceived in a way to simplify the manipulations and to reduce the more possible the contamination risks are suitable for determination in series. By working on trial samples near 250 mg, the lower determination limits are around 2 ppb for cadmium, 40 ppb for lead and tin and 2 ppm for zinc. The repeatability studies of different technical stages show that mineralisation and extraction only have a weak incidence on the acccuracy of the results [fr

  3. A pre-concentration procedure using coprecipitation for determination of lead and iron in several samples using flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Saracoglu, S.; Soylak, M.; Peker, D.S. Kacar; Elci, L.; Santos, W.N.L. dos; Lemos, V.A.; Ferreira, S.L.C.

    2006-01-01

    The present paper proposes a pre-concentration procedure for determination of lead and iron in several samples by flame atomic absorption spectrometry. In it, lead(II) and iron(III) ions are coprecipitated using the violuric acid-copper(II) system as collector. Afterwards, the precipitate is dissolved with 1 M HNO 3 solution and the metal ions are determined. The optimization step was performed using factorial design involving the variables: pH, violuric acid mass (VA) and copper concentration (Cu). Using the optimized experimental conditions, the proposed procedure allows the determination these metals with detection limits of 0.18 μg L -1 for iron and 0.16 μg L -1 for lead. The effects of foreign ions on the pre-concentration procedure were also evaluated and the results demonstrated that this method could be applied for determination of iron and lead in several real samples. The proposed method was successfully applied to the analysis of seawater, urine, mineral water, soil and physiological solution samples. The concentrations of lead and iron achieved in these samples agree well with others data reported in the literature

  4. High-pressure Raman and optical absorption studies on lead pyroniobate (Pb2Nb2O7) and pressure-induced phase transitions

    International Nuclear Information System (INIS)

    Jayaraman, A.; Kourouklis, G.A.; Cooper, A.S.; Espinosa, G.P.

    1990-01-01

    High-pressure Raman scattering and optical absorption studies have been carried out on lead pyroniobate (Pb 2 Nb 2 O 7 ) up to 33 GPa, using a gasketed diamond anvil cell. The Raman study reveals the occurrence of two, possibly three, pressure-induced phase changes; a rather subtle change is indicated near 4.5 GPa. The transition near 13 GPa is attributed to a structural transition from the rhombohedral to the cubic pyrochlore structure. The third phase change occurs near 20 GPa. From the broad Raman feature that is observed at about 800 cm -1 , it is concluded that the system turns amorphous at pressures above 20 GPa. The amorphous phase recrystallizes to the original rhombohedral phase, on release of pressure. The broad Raman peaks of the recrystallized phase indicate a high degree of disorder in the material. Lead pyroniobate turns deep red near 30 GPa, from light yellow at ambient pressure. Semi quantitative absorption measurements show that the energy gap shifts red at a rate of 30 meV/GPa. This shift is attributed to the downward motion of the 5d (es) conduction band of Pb

  5. Effects of Red-mud and Organic Fertilizer on Cadmium and Lead Absorption and Distribution in Rice

    OpenAIRE

    FANG Ya-yu; ZOU Hui-ling; YIN Xiao-hui; CHEN Nan; YANG Deng; WEI Xiang-dong

    2016-01-01

    Effects of red mud and organic fertilizer on distribution of cadmium(Cd) and lead (Pb) in soil-rice system were studied in field by orthogonal test. Results showed that after red mud and organic fertilizer added including single and combined, the soil pH value increased 0.36~1.90 units, contents of Cd and Pb in rice rhizosphere soil decreased 2.73%~26.25% and 7.15%~34.26% respectively and contents of Cd and Pb in brown rice decreased 23.24%~55.90% and 11.76%~29.41% respectively. In all treatm...

  6. Lead determinations in human bone by particle induced x-ray emission (PIXE) and graphite furnace atomic absorption spectrometry (GFAAS)

    Energy Technology Data Exchange (ETDEWEB)

    Deibel, M A; Savage, J M; Robertson, J D; Ehmann, W D [Kentucky Univ., Lexington, KY (United States). Dept. of Chemistry; Markesbery, W R [Kentucky Univ., Lexington, KY (United States)

    1995-08-01

    Chronic lead (Pb) intoxication has been linked to Alzheimer`s disease (AD). Lead, like many heavy elements, tends to accumulate in bone. Pixe is a powerful analytical tool which permits the determination of Pb at the {mu}g/g level without requiring sample digestion. GFAAS is one of the most sensitive methods for the determination of Pb and is capable of determining ng/g levels is solution. For bone analyses by GFAAS, sample dissolution and a matrix modifier are required. Rib bone samples were analyzed for Pb by PIXE and GFAAS. IAEA Animal Bone (H-5) was used as a secondary standard for Pb with both methods to ensure accuracy. The range of Pb concentrations in human rib bone was 1.4-11.5 {mu}/g for the trabecular surface by PIXE, 1.3-45 {mu}g/g for the cortical surface by PIXE, and 1.54-11.75 {mu}g/g for whole bone by GFAAS. No significant difference p.<0.05 was found for AD versus control for either surface or for whole bone. (author). 17 refs., 2 figs., 3 tabs.

  7. Lead determinations in human bone by particle induced x-ray emission (PIXE) and graphite furnace atomic absorption spectrometry (GFAAS)

    International Nuclear Information System (INIS)

    Deibel, M.A.; Savage, J.M.; Robertson, J.D.; Ehmann, W.D.

    1995-01-01

    Chronic lead (Pb) intoxication has been linked to Alzheimer's disease (AD). Lead, like many heavy elements, tends to accumulate in bone. Pixe is a powerful analytical tool which permits the determination of Pb at the μg/g level without requiring sample digestion. GFAAS is one of the most sensitive methods for the determination of Pb and is capable of determining ng/g levels is solution. For bone analyses by GFAAS, sample dissolution and a matrix modifier are required. Rib bone samples were analyzed for Pb by PIXE and GFAAS. IAEA Animal Bone (H-5) was used as a secondary standard for Pb with both methods to ensure accuracy. The range of Pb concentrations in human rib bone was 1.4-11.5 μ/g for the trabecular surface by PIXE, 1.3-45 μg/g for the cortical surface by PIXE, and 1.54-11.75 μg/g for whole bone by GFAAS. No significant difference (p.<0.05 was found for AD versus control for either surface or for whole bone. (author). 17 refs., 2 figs., 3 tabs

  8. [Determination of trace lead and cadmium in transgenic rice by crosslinked carboxymethyl konjac glucomannan microcolumn preconcentration combined with graphite furnace atomic absorption spectrometry].

    Science.gov (United States)

    Liu, Hua-qing; Li, Sheng-qing; Qu, Yang; Chen, Hao

    2012-02-01

    A novel method was developed for the determination of trace lead and cadmium in transgenic brown rice based on separation and preconcentration with a micro column packed with crosslinked carboxymethyl konjac glucomannan (CCMKGM) prior to its determination by graphite furnace atomic absorption spectrometry. Variables affecting the separation and preconcentration of lead and cadmium, such as the acidity of the aqueous solution, sample flow rate and volume, and eluent concentration and volume, were optimized. Under optimized condition, detection limits of the method for the determination of trace lead and cadmium in transgenic brown rice were 0.11 and 0.002 microg x L(-1), respectively. The obtained results of lead and cadmium in the certified reference material (GBW10010, GBS1-1) were in good agreement with the certified values. The recoveries were in the range of 90%-103% and 93%-105% for detection of Pb and Cd in transgenic brown rice and the wild-type brown rice samples respectively. This study could provide technical support for determination of trace Pb and Cd in transgenic rice.

  9. Solid phase extraction of lead on octadecyl bonded silica membrane disk modified with Cyanex302 and determination by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Karve, Manjusha; Rajgor, Reeta V.

    2007-01-01

    A simple, reliable and rapid method for preconcentration and determination of lead using octadecyl bonded silica membrane disk impregnated with Cyanex302 and flame atomic absorption spectrometry is presented. The influence of aqueous phase pH, type of eluent, flow rates of sample solution and eluent, volume of eluent and amount of extractant has been investigated. The break through volume is greater than 4.0 dm 3 with an enrichment factor of more than 400 and a detection limit of 1.0 μg dm -3 . The method developed for determination of lead is good as six replicate determinations using 100 cm 3 solution containing lead in the range 1-4900 μg provides a relative standard deviation (R.S.D.) of 0.4%. The selectivity of the proposed method was confirmed from the interference studies. The developed procedure was successfully applied for the determination of lead in spiked sea water, USGS standard soil sample, sludge and industrial effluents, medicinal formulation, plant, some food products and wine

  10. [Study on Content Determination of Lead and Arsenic in Four Traditional Tibetan Medicine Prescription Preparations by Wet Digestion Flow Injection-Hydride Generation-Atomic Absorption Spectrometry].

    Science.gov (United States)

    Zheng, Zhi-yuan; Du, Yu-zhi; Zhang, Ming; Yu, Ming-jie; Li, Cen; Yang, Hong-xia; Zhao, Jing; Xia, Zheng-hua; Wei, Li-xin

    2015-04-01

    Four common traditional tibetan medicine prescription preparations "Anzhijinghuasan, Dangzuo, Renqingchangjue and Rannasangpei" in tibetan areas were selected as study objects in the present study. The purpose was to try to establish a kind of wet digestion and flow injection-hydride generation-atomic absorption spectrometry (FI-HAAS) associated analysis method for the content determinations of lead and arsenic in traditional tibetan medicine under optimized digestion and measurement conditions and determine their contents accurately. Under these optimum operating conditions, experimental results were as follows. The detection limits for lead and arsenic were 0.067 and 0.012 µg · mL(-1) respectively. The quantification limits for lead and arsenic were 0.22 and 0.041 µg · mL(-1) respectively. The linear ranges for lead and arsenic were 25-1,600 ng · mL(-1) (r = 0.9995) and 12.5-800 ng · mL(-1) (r = 0.9994) respectively. The degrees of precision(RSD) for lead and arsenic were 2.0% and 3.2% respectively. The recovery rates for lead and arsenic were 98.00%-99.98% and 96.67%-99.87% respectively. The content determination results of lead and arsenic in four traditional tibetan medicine prescription preparations were as fol- lows. The contents of lead and arsenic in Anzhijinghuasan are 0.63-0.67 µg · g(-1) and 0.32-0.33 µg · g(-1) in Anzhijinghua- san, 42.92-43.36 µg · g(-1) and 24.67-25.87 µg · g(-1) in Dangzuo, 1,611. 39-1,631.36 µg · g(-1) and 926.76-956.52 µg- g(-1) in Renqing Changjue, and 1,102.28-1,119.127 µg-g(-1) and 509.96-516.87 µg · g(-1) in Rannasangpei, respectively. This study established a method for content determination of lead and arsenic in traditional tibetan medicine, and determined the content levels of lead and arsenic in four tibetan medicine-prescription preparations accurately. In addition, these results also provide the basis for the safe and effective use of those medicines in clinic.

  11. Effects of Red-mud and Organic Fertilizer on Cadmium and Lead Absorption and Distribution in Rice

    Directory of Open Access Journals (Sweden)

    FANG Ya-yu

    2016-09-01

    Full Text Available Effects of red mud and organic fertilizer on distribution of cadmium(Cd and lead (Pb in soil-rice system were studied in field by orthogonal test. Results showed that after red mud and organic fertilizer added including single and combined, the soil pH value increased 0.36~1.90 units, contents of Cd and Pb in rice rhizosphere soil decreased 2.73%~26.25% and 7.15%~34.26% respectively and contents of Cd and Pb in brown rice decreased 23.24%~55.90% and 11.76%~29.41% respectively. In all treatments, single red mud was best, followed by red mud and organic fertilizer combined, single organic fertilizer was worst. The content of Cd and Pb in different rice organs with addition of red mud and organic fertilizer decreased significantly, the contribution rate of Cd and Pb at different stages changed obviously, and influences of adding quantity and fertilizing method were also significant. Different treatments had different effects on contents of Cd and Pb in brown rice. Compared with CK, red mud (4 000 kg·hm-2 was the best for Cd, combination of red mud (4 000 kg·hm-2 and organic fertilizer (1 000 kg·hm-2was the best for Pb, the contents of which were 55.90% and 29.41% less than the control respectively. Although contents of Cd and Pb in brown rice decreased significantly after red mud and organic fertilizer added, contents of Cd and Pb in brown rice were still higher than national food safety standards (GB 2762-2012 because of high polluted degree of Cd (65 times than standard and Pb(7 times than standard in soil. All results showed it was ineffective to control heavy metal pollution in brown rice only by red mud and organic fertilizer addition in high polluted degree soils.

  12. Feasibility study on reducing lead and cadmium absorption by spinach (Spinacia oleracea L.) in a contaminated soil using nanoporous activated carbon

    International Nuclear Information System (INIS)

    Sara Darvishi; Mohammad Reza Ardakani; Saeed Vazan; Farzad Paknejad; Amir Hossein Faregh; Hossein Ghafourian

    2012-01-01

    Activated carbons (AC) have been long recognized as prominent absorbents in industries and feature numerous applications in preventing or absorbing the harmful gases and liquids and could be employed for filtration and remediation or even reutilization of chemicals. In order to investigate the capacity of AC in reducing the absorption of heavy metals (HM) including lead (Pb) and cadmium (Cd) and dual complex (Pb x Cd) by spinach, a factorial experiment in a completely randomized design with three replications on a pot trial was conducted. Three factors including five levels of AC 0, 5000, 10000, 15000, 20000 mg/kg soil, one concentration level of Pb 4,000 mg/kg soil and one concentration level of cadmium Cd 8 mg/kg soil were tested. The index of heavy metal concentration was calculated in leaf, stem and root and their corresponding dry weights. Results illustrated that in contaminated soils, plants with AC exhibited a superior reduction of absorption of HM vis-a-vis the plants without AC. The foremost result regarding the impact of AC on reducing the concentration of Pb and Cd was observed in 20,000 level of AC. This reveals that AC declined the soil contamination and lessened the accumulation of HM into the shoots and roots. Results suggest that the application of AC may be an eligible solution for decreasing the translocation of HM into the plants. (author)

  13. In Situ Solid-State Reactions Monitored by X-ray Absorption Spectroscopy: Temperature-Induced Proton Transfer Leads to Chemical Shifts.

    Science.gov (United States)

    Stevens, Joanna S; Walczak, Monika; Jaye, Cherno; Fischer, Daniel A

    2016-10-24

    The dramatic colour and phase alteration with the solid-state, temperature-dependent reaction between squaric acid and 4,4'-bipyridine has been probed in situ with X-ray absorption spectroscopy. The electronic and chemical sensitivity to the local atomic environment through chemical shifts in the near-edge X-ray absorption fine structure (NEXAFS) revealed proton transfer from the acid to the bipyridine base through the change in nitrogen protonation state in the high-temperature form. Direct detection of proton transfer coupled with structural analysis elucidates the nature of the solid-state process, with intermolecular proton transfer occurring along an acid-base chain followed by a domino effect to the subsequent acid-base chains, leading to the rapid migration along the length of the crystal. NEXAFS thereby conveys the ability to monitor the nature of solid-state chemical reactions in situ, without the need for a priori information or long-range order. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. In situ emulsification microextraction using a dicationic ionic liquid followed by magnetic assisted physisorption for determination of lead prior to micro-sampling flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Shokri, Masood; Beiraghi, Asadollah; Seidi, Shahram

    2015-01-01

    For the first time, a simple and efficient in situ emulsification microextraction method using a dicationic ionic liquid followed by magnetic assisted physisorption was presented to determine trace amounts of lead. In this method, 400 μL of 1.0 mol L −1 lithium bis (trifluoromethylsulfonyl) imide aqueous solution, Li[NTf 2 ], was added into the sample solution containing 100 μL of 1.0 mol L −1 1,3-(propyl-1,3-diyl) bis (3-methylimidazolium) chloride, [pbmim]Cl 2 , to form a water immiscible ionic liquid, [pbmim][NTf 2 ] 2 . This new in situ formed dicationic ionic liquid was applied as the acceptor phase to extract the lead-ammonium pyrrolidinedithiocarbamate (Pb-APDC) complexes from the sample solution. Subsequently, 30 mg of Fe 3 O 4 magnetic nanoparticles (MNPs) were added into the sample solution to collect the fine droplets of [pbmim][NTf 2 ] 2 , physisorptively. Finally, MNPs were eluted by acetonitrile, separated by an external magnetic field and the obtained eluent was subjected to micro-sampling flame atomic absorption spectrometry (FAAS) for further analysis. Comparing with other microextraction methods, no special devices and centrifugation step are required. Parameters influencing the extraction efficiency such as extraction time, pH, concentration of chelating agent, amount of MNPs and coexisting interferences were studied. Under the optimized conditions, this method showed high extraction recovery of 93% with low LOD of 0.7 μg L −1 . Good linearity was obtained in the range of 2.5–150 μg L −1 with determination coefficient (r 2 ) of 0.9921. Relative standard deviation (RSD%) for seven repeated measurements at the concentration of 10 μg L −1 was 4.1%. Finally, this method was successfully applied for determination of lead in some water and plant samples. - Highlights: • A dicationic ionic liquid was used as the extraction solvent, for the first time. • A simple and efficient in situ emulsification microextraction

  15. Preconcentration of trace amounts of lead in water samples with cetyltrimethylammonium bromide coated magnetite nanoparticles and its determination by flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Mohammad Faraji

    2016-11-01

    Full Text Available A sensitive and simple magnetic solid phase extraction procedure was presented for the preconcentration of lead ions in environmental water samples. In the present study, lead ions form complexes with 1-(2-pyridilazo-2-naphthol reagent (PAN in basic medium, and then are quantitatively extracted to the surface of cetyltrimethylammonium bromide (CTAB-coated magnetite nanoparticles (Fe3O4 NPs. After magnetic separation of adsorbent, the adsorbent was eluted with 0.5% (v/v HCl in methanol prior to its analysis by flame atomic absorption spectrometry (FAAS. The pH of sample, concentrations of PAN, amounts of CTAB and Fe3O4 NPs, sample volume and desorption conditions were optimized. Under optimum conditions, the calibration curve was linear in the range of 0.05–100 ng mL−1 with R2 = 0.9996. Detection and quantification limits of the proposed method were 0.005 and 0.05 ng mL−1, respectively. Enhancement factor of 1050 was achieved using this method to extract 1000 mL of different environmental water samples. Compared with conventional solid phase extraction methods, the advantages of this method still include easy preparation of sorbents, short times of sample pre-treatment, high extraction yield, and high breakthrough volume. It shows great analytical potential in preconcentration of lead from large volume water samples.

  16. Separation/preconcentration of silver(I) and lead(II) in environmental samples on cellulose nitrate membrane filter prior to their flame atomic absorption spectrometric determinations

    International Nuclear Information System (INIS)

    Soylak, Mustafa; Cay, Rukiye Sungur

    2007-01-01

    An enrichment method for trace amounts of Ag(I) and Pb(II) has been established prior to their flame atomic absorption spectrometric determinations. The preconcentration/separation procedure is based on chelate formation of Ag(I) and Pb(II) with ammonium pyrrolidine dithiocarbamate (APDC) and on retention of the chelates on cellulose nitrate membrane filter. The influences of some analytical parameters including pH and amounts of reagent, etc. on the recoveries of analytes were investigated. The effects of interferic ions on the quantitative recoveries of analytes were also examined. The detection limits (k = 3, N = 11) were 4.6 μg L -1 for silver(I) and 15.3 μg L -1 for lead(II). The relative standard deviations (R.S.D.) of the determinations for analyte ions were below 3%. The method was applied to environmental samples for the determination of analyte ions with satisfactory results (recoveries >95%)

  17. Cadmium, copper, lead, and zinc determination in precipitation: A comparison of inductively coupled plasma atomic emission spectrometry and graphite furnace atomization atomic absorption spectrometry

    Science.gov (United States)

    Reddy, M.M.; Benefiel, M.A.; Claassen, H.C.

    1987-01-01

    Selected trace element analysis for cadmium, copper, lead, and zinc in precipitation samples by inductively coupled plasma atomic emission Spectrometry (ICP) and by atomic absorption spectrometry with graphite furnace atomization (AAGF) have been evaluated. This task was conducted in conjunction with a longterm study of precipitation chemistry at high altitude sites located in remote areas of the southwestern United States. Coefficients of variation and recovery values were determined for a standard reference water sample for all metals examined for both techniques. At concentration levels less than 10 micrograms per liter AAGF analyses exhibited better precision and accuracy than ICP. Both methods appear to offer the potential for cost-effective analysis of trace metal ions in precipitation. ?? 1987 Springer-Verlag.

  18. Preconcentration and atomic absorption spectrometric determination of cadmium, cobalt, copper, iron, lead, manganese, nickel and zinc in water samples using 6-methyl-2-pyridinecarboxaldehyde-4-phenyl-3-thiosemicarbazone

    International Nuclear Information System (INIS)

    Khuhawar, M.Y.; Das, P.; Dewani, V.K.

    2005-01-01

    The reagent 6-methyl-2-pyridinecarboxaldehyde-4-phenyl-3-thiosemicarbazone (MPAPT) has been examined for the pre-concentration of metal ions and determination using air acetylene flame atomic absorption spectrometer. The method is based on the complexation and extraction of cadmium (II), cobalt(III), copper(II), lead(II), nickel(II), iron(II), iron(II), manganese(II) and zinc(II) in chloroform. The metal iron are back extracted in nitric acid (1:1) or after evaporation of solvent the residue is digested in nitric acid. After necessary adjustment of volume the metal ions were determined in aqueous solution. Pre-concentration is obtained 10-25 times. Metal ions recovery was 95.4-100.8% with coefficient of variation 0.2-7.5%. The method used for the determination of metals in canal and sewerage waters, within 2-6433 mu g/L with C. V 0.-5.2%. (author)

  19. Multiwalled carbon nanotubes as a sorbent material for the solid phase extraction of lead from urine and subsequent determination by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Peña Crecente, Rosa M.; Lovera, Carlha Gutiérrez; García, Julia Barciela; Méndez, Jennifer Álvarez; Martín, Sagrario García; Latorre, Carlos Herrero, E-mail: carlos.herrero@usc.es

    2014-11-01

    The determination of lead in urine is a way of monitoring the chemical exposure to this metal. In the present paper, a new method for the Pb determination by electrothermal atomic absorption spectrometry (ETAAS) in urine at low levels has been developed. Lead was separated from the undesirable urine matrix by means of a solid phase extraction (SPE) procedure. Oxidized multiwalled carbon nanotubes have been used as a sorbent material. Lead from urine was retained at pH 4.0 and was quantitatively eluted using a 0.7 M nitric acid solution and was subsequently measured by ETAAS. The effects of parameters that influence the adsorption–elution process (such as pH, eluent volume and concentration, sampling and elution flow rates) and the atomic spectrometry conditions have been studied by means of different factorial design strategies. Under the optimized conditions, the detection and quantification limits obtained were 0.08 and 0.26 μg Pb L{sup −1}, respectively. The results demonstrate the absence of a urine matrix effect and this is the consequence of the SPE process carried out. Therefore, the developed method is useful for the analysis of Pb at low levels in real samples without the influence of other urine components. The proposed method was applied to the determination of lead in urine samples of unexposed healthy people and satisfactory results were obtained (in the range 3.64–22.9 μg Pb L{sup −1}). - Highlights: • Lead determination in urine using a solid phase extraction procedure followed by ETAAS • Carbon nanotubes as SPE adsorbent for Pb in urine • Matrix elimination for the Pb determination in urine by using SPE based on carbon nanotubes • The detection limit was 0.08 μg Pb L{sup −1}.

  20. Randomized controlled trial of the effects of high intensity and low-to-moderate intensity exercise on physical fitness and fatigue in cancer survivors: results of the Resistance and Endurance exercise After ChemoTherapy (REACT) study.

    Science.gov (United States)

    Kampshoff, Caroline S; Chinapaw, Mai J M; Brug, Johannes; Twisk, Jos W R; Schep, Goof; Nijziel, Marten R; van Mechelen, Willem; Buffart, Laurien M

    2015-10-29

    International evidence-based guidelines recommend physical exercise to form part of standard care for all cancer survivors. However, at present, the optimum exercise intensity is unclear. Therefore, we aimed to evaluate the effectiveness of a high intensity (HI) and low-to-moderate intensity (LMI) resistance and endurance exercise program compared with a wait list control (WLC) group on physical fitness and fatigue in a mixed group of cancer survivors who completed primary cancer treatment, including chemotherapy. Overall, 277 cancer survivors were randomized to 12 weeks of HI exercise (n = 91), LMI exercise (n = 95), or WLC (n = 91). Both interventions were identical with respect to exercise type, duration and frequency, and only differed in intensity. Measurements were performed at baseline (4-6 weeks after primary treatment) and post-intervention. The primary outcomes were cardiorespiratory fitness (peakVO2), muscle strength (grip strength and 30-second chair-stand test), and self-reported fatigue (Multidimensional Fatigue Inventory; MFI). Secondary outcomes included health-related quality of life, physical activity, daily functioning, body composition, mood, and sleep disturbances. Multilevel linear regression analyses were performed to estimate intervention effects using an intention-to-treat principle. In the HI and LMI groups, 74 % and 70 % of the participants attended more than 80 % of the prescribed exercise sessions, respectively (P = 0.53). HI (β = 2.2; 95 % CI, 1.2-3.1) and LMI (β = 1.3; 95 % CI, 0.3-2.3) exercise showed significantly larger improvements in peakVO2 compared to WLC. Improvements in peakVO2 were larger for HI than LMI exercise (β = 0.9; 95 % CI, -0.1 to 1.9), but the difference was not statistically significant (P = 0.08). No intervention effects were found for grip strength and the 30-second chair-stand test. HI and LMI exercise significantly reduced general and physical fatigue and reduced activity

  1. Applicability of cloud point extraction for the separation trace amount of lead ion in environmental and biological samples prior to determination by flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Sayed Zia Mohammadi

    2016-09-01

    Full Text Available A sensitive cloud point extraction procedure(CPE for the preconcentration of trace lead prior to its determination by flame atomic absorption spectrometry (FAAS has been developed. The CPE method is based on the complex of Pb(II ion with 1-(2-pyridylazo-2-naphthol (PAN, and then entrapped in the non-ionic surfactant Triton X-114. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of PAN and Triton X-114, equilibration temperature and time, were investigated in detail. A preconcentration factor of 30 was obtained for the preconcentration of Pb(II ion with 15.0 mL solution. Under the optimal conditions, the calibration curve was linear in the range of 7.5 ng mL−1–3.5 μg mL−1 of lead with R2 = 0.9998 (n = 10. Detection limit based on three times the standard deviation of the blank (3Sb was 5.27 ng mL−1. Eight replicate determinations of 1.0 μg mL−1 lead gave a mean absorbance of 0.275 with a relative standard deviation of 1.6%. The high efficiency of cloud point extraction to carry out the determination of analytes in complex matrices was demonstrated. The proposed method has been applied for determination of trace amounts of lead in biological and water samples with satisfactory results.

  2. Validation of the methodology for the quantitative determination of lead in cosmetics dyes available in the national market by atomic absorption spectroscopy with flame

    International Nuclear Information System (INIS)

    Silva Trejos, Paulina

    2008-01-01

    The analytical methodology was validated to quantify lead in cosmetics dyes available on the national market, by the method of atomic absorption spectroscopy with flame. The samples were digested by wet digestion with HNO 3 to 65% m/m in a microwave oven, the percentage of recovery for the digestion of samples of 0,25 g and 0,45 g in 5,00 mL was of 100,5±0,5. The field of optimal linearity detection limit was 5,0 mg/L with a correlation coefficient of 0,9998. The limits of detection and quantification limits determined graphically by the method of row errors for linear regression of 0,12±0,02 mg/L and 0,21±0,02 mg/L, respectively. Precision was evaluated determining the repeatability as standard deviation of five replicas of a positive dye for lead, according to the definition of the ISO, 2√2*, and obtained a value of 2,3. The veracity was determined through percentages of recovery assessed, adding aliquots of lead patterns to dye samples and compared with the same mass to which they are not make additions. The dye samples were obtained at point of sale, such as pharmacies, beauty suppliers, supermarkets, sales of natural products and the central market of San Jose. The dyes tested contain lead acetates active ingredient, these are: Doni, Mont D'Or, Matador y Siempre Joven; they are produced locally, Youthair brand and American manufacturing. (author) [es

  3. Investigation of spectral interferences in the determination of lead in fertilizers and limestone samples using high-resolution continuum source graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Aline R. [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Becker, Emilene M.; François, Luciane L.; Jesus, Alexandre de [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Vale, Maria Goreti R. [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Welz, Bernhard [Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Dessuy, Morgana B., E-mail: mbdessuy@ufrgs.br [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Andrade, Jailson B. de [Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil)

    2014-11-01

    In the present work, spectral interferences on the determination of lead in fertilizer and limestone samples were investigated using high-resolution continuum source graphite furnace atomic absorption spectrometry at the main analytical lines: 217.001 and 283.306 nm. For these investigations, samples were introduced into the furnace as slurry together with a mixture of Pd and Mg as chemical modifier. Spectral interferences were observed for some samples at both analytical lines. In order to verify whether a wet digestion procedure would avoid these interferences, a reference method for wet digestion of fertilizers was employed as an alternative sample preparation procedure. However, the same interferences were also observed in the digested samples. In order to identify and eliminate the fine-structured background using a least-squares background correction, reference spectra were generated using the combination of different species. The use of the latter technique allowed the elimination of spectral interferences for most of the investigated samples, making possible the determination of lead in fertilizer and limestone samples free of interferences. The best results were found using a reference spectrum of NH{sub 4}H{sub 2}PO{sub 4} at 217.001 nm, and a mixture of H{sub 2}SO{sub 4} + Ca and HNO{sub 3} + Ca at the 283.306 nm line. The accuracy of the method was evaluated using a certified reference material “Trace Elements in Multi-Nutrient Fertilizer”. Similar results were obtained using line source graphite furnace atomic absorption spectrometry with Zeeman-effect background correction, indicating that the latter technique was also capable to correct the spectral interferences, at least in part. - Highlights: • Spectral interferences on the determination of lead in fertilizers and limestone. • The analytical lines at 217.001 nm and 283.306 nm using HR-CS GF AAS. • Various combinations of compounds were used to create reference spectra. • LSBC

  4. Cloud point extraction and flame atomic absorption spectrometric determination of cadmium(II), lead(II), palladium(II) and silver(I) in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Ghaedi, Mehrorang, E-mail: m_ghaedi@mail.yu.ac.ir [Chemistry Department, Yasouj University, Yasouj 75914-353 (Iran, Islamic Republic of); Shokrollahi, Ardeshir [Chemistry Department, Yasouj University, Yasouj 75914-353 (Iran, Islamic Republic of); Niknam, Khodabakhsh [Chemistry Department, Persian Gulf University, Bushehr (Iran, Islamic Republic of); Niknam, Ebrahim; Najibi, Asma [Chemistry Department, Yasouj University, Yasouj 75914-353 (Iran, Islamic Republic of); Soylak, Mustafa [Chemistry Department, University of Erciyes, 38039 Kayseri (Turkey)

    2009-09-15

    The phase-separation phenomenon of non-ionic surfactants occurring in aqueous solution was used for the extraction of cadmium(II), lead(II), palladium(II) and silver(I). The analytical procedure involved the formation of understudy metals complex with bis((1H-benzo [d] imidazol-2yl)ethyl) sulfane (BIES), and quantitatively extracted to the phase rich in octylphenoxypolyethoxyethanol (Triton X-114) after centrifugation. Methanol acidified with 1 mol L{sup -1} HNO{sub 3} was added to the surfactant-rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). The concentration of BIES, pH and amount of surfactant (Triton X-114) was optimized. At optimum conditions, the detection limits of (3 sdb/m) of 1.4, 2.8, 1.6 and 1.4 ng mL{sup -1} for Cd{sup 2+}, Pb{sup 2+}, Pd{sup 2+} and Ag{sup +} along with preconcentration factors of 30 and enrichment factors of 48, 39, 32 and 42 for Cd{sup 2+}, Pb{sup 2+}, Pd{sup 2+} and Ag{sup +}, respectively, were obtained. The proposed cloud point extraction has been successfully applied for the determination of metal ions in real samples with complicated matrix such as radiology waste, vegetable, blood and urine samples.

  5. Cloud point extraction and flame atomic absorption spectrometric determination of cadmium(II), lead(II), palladium(II) and silver(I) in environmental samples

    International Nuclear Information System (INIS)

    Ghaedi, Mehrorang; Shokrollahi, Ardeshir; Niknam, Khodabakhsh; Niknam, Ebrahim; Najibi, Asma; Soylak, Mustafa

    2009-01-01

    The phase-separation phenomenon of non-ionic surfactants occurring in aqueous solution was used for the extraction of cadmium(II), lead(II), palladium(II) and silver(I). The analytical procedure involved the formation of understudy metals complex with bis((1H-benzo [d] imidazol-2yl)ethyl) sulfane (BIES), and quantitatively extracted to the phase rich in octylphenoxypolyethoxyethanol (Triton X-114) after centrifugation. Methanol acidified with 1 mol L -1 HNO 3 was added to the surfactant-rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). The concentration of BIES, pH and amount of surfactant (Triton X-114) was optimized. At optimum conditions, the detection limits of (3 sdb/m) of 1.4, 2.8, 1.6 and 1.4 ng mL -1 for Cd 2+ , Pb 2+ , Pd 2+ and Ag + along with preconcentration factors of 30 and enrichment factors of 48, 39, 32 and 42 for Cd 2+ , Pb 2+ , Pd 2+ and Ag + , respectively, were obtained. The proposed cloud point extraction has been successfully applied for the determination of metal ions in real samples with complicated matrix such as radiology waste, vegetable, blood and urine samples.

  6. A Green Preconcentration Method for Determination of Cobalt and Lead in Fresh Surface and Waste Water Samples Prior to Flame Atomic Absorption Spectrometry

    Directory of Open Access Journals (Sweden)

    Naeemullah

    2012-01-01

    Full Text Available Cloud point extraction (CPE has been used for the preconcentration and simultaneous determination of cobalt (Co and lead (Pb in fresh and wastewater samples. The extraction of analytes from aqueous samples was performed in the presence of 8-hydroxyquinoline (oxine as a chelating agent and Triton X-114 as a nonionic surfactant. Experiments were conducted to assess the effect of different chemical variables such as pH, amounts of reagents (oxine and Triton X-114, temperature, incubation time, and sample volume. After phase separation, based on the cloud point, the surfactant-rich phase was diluted with acidic ethanol prior to its analysis by the flame atomic absorption spectrometry (FAAS. The enhancement factors 70 and 50 with detection limits of 0.26 μg L−1 and 0.44 μg L−1 were obtained for Co and Pb, respectively. In order to validate the developed method, a certified reference material (SRM 1643e was analyzed and the determined values obtained were in a good agreement with the certified values. The proposed method was applied successfully to the determination of Co and Pb in a fresh surface and waste water sample.

  7. Cloud point extraction for determination of lead in blood samples of children, using different ligands prior to analysis by flame atomic absorption spectrometry: A multivariate study

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Faheem, E-mail: shah_ceac@yahoo.com [National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Kazi, Tasneem Gul, E-mail: tgkazi@yahoo.com [National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Afridi, Hassan Imran, E-mail: hassanimranafridi@yahoo.com [National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Naeemullah, E-mail: khannaeemullah@ymail.com [National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan); Arain, Muhammad Balal, E-mail: bilal_ku2004@yahoo.com [Department of Chemistry, University of Science and Technology, Bannu, KPK (Pakistan); Baig, Jameel Ahmed, E-mail: jab_mughal@yahoo.com [National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)

    2011-09-15

    Highlights: {yields} Trace levels of lead in blood samples of healthy children and with different kidney disorders {yields} Pre-concentration of Pb{sup +2} in acid digested blood samples after chelating with two complexing reagents. {yields} Multivariate technique was used for screening of significant factors that influence the CPE of Pb{sup +2} {yields} The level of Pb{sup +2} in diseased children was significantly higher than referents of same age group. - Abstract: The phase-separation phenomenon of non-ionic surfactants occurring in aqueous solution was used for the extraction of lead (Pb{sup 2+}) from digested blood samples after simultaneous complexation with ammonium pyrrolidinedithiocarbamate (APDC) and diethyldithiocarbamate (DDTC) separately. The complexed analyte was quantitatively extracted with octylphenoxypolyethoxyethanol (Triton X-114). The multivariate strategy was applied to estimate the optimum values of experimental factors. Acidic ethanol was added to the surfactant-rich phase prior to its analysis by flame atomic absorption spectrometer (FAAS). The detection limit value of Pb{sup 2+} for the preconcentration of 10 mL of acid digested blood sample was 1.14 {mu}g L{sup -1}. The accuracy of the proposed methods was assessed by analyzing certified reference material (whole blood). Under the optimized conditions of both CPE methods, 10 mL of Pb{sup 2+} standards (10 {mu}g L{sup -1}) complexed with APDC and DDTC, permitted the enhancement factors of 56 and 42, respectively. The proposed method was used for determination of Pb{sup 2+} in blood samples of children with kidney disorders and healthy controls.

  8. Zinc, copper and lead contents of wines. Comparison between the total concentrations by atomic absorption spectrometry and the concentrations of the free ions by polarography

    Directory of Open Access Journals (Sweden)

    J.-B. Fournier

    1998-03-01

    Full Text Available In the introduction of this article, some examples of the use of trace element data in the characterisation of viticultural produce are reminded. This paper described the determination of zinc, copper and lead by two techniques based on radically different principles. The atomic absorption spectrometry, applied after the mineralisation of the samples by wet process, allows the determination of the total element contents in wine. The polarography allows the analysis of the concentrations of these elements that are under labile chemical forms, and which are dissolved under the ionic forms Zn++, Cu++ and Pb++. The wines analysed in this study were produced from three different parcels chosen in relation to their geological qualities. The vines implanted on these parcels are strictly identical, and three fermentation techniques were applied to each lots of grapes. The results obtained shows that the copper is only under ionic form and that the temperature of the fermentation influences the total copper level in the final wine. At the opposite, there is no ion Pb++ in the samples, but a long duration of maceration increases the lead content. Concerning zinc, only the ions Zn++ are present in the wine in case of a short duration of the maceration. When this duration increases, some other chemical forms of zinc are dissolved in addition to the ions Zn++ which are instantaneously dissociated in aqueous solutions. The problem of the contamination of grapes by the materials used, the phytosanitary treatments and the atmospheric pollution is discussed. The knowledge of the proportion of a trace element that is under ionic forms is indispensable to evaluate the bio-availability of the considered element and the toxicologic risks. The advent and the expansion of the electrochemical methods is expected as an important advance in this field of research.

  9. Graphene-based solid-phase extraction combined with flame atomic absorption spectrometry for a sensitive determination of trace amounts of lead in environmental water and vegetable samples

    International Nuclear Information System (INIS)

    Wang Yukun; Gao Shutao; Zang Xiaohuan; Li Jingci; Ma Jingjun

    2012-01-01

    Highlights: ► Graphene as a novel sorbent material in a column for solid-phase extraction (SPE). ► SPE for the determination of lead (Pb) in environment water samples and vegetable samples. ► The system can be reused for many times. ► The adsorption capacity of graphene over many other adsorbents. ► Graphene has great potentials as an excellent sorbent material. - Abstract: Graphene, a novel class of carbon nanostructures, has great promise for use as sorbent materials because of its ultrahigh specific surface area. A new method using a column packed with graphene as sorbent was developed for the preconcentration of trace amounts of lead (Pb) using dithizone as chelating reagent prior to its determination by flame atomic absorption spectrometry. Some effective parameters on the extraction and complex formation were selected and optimized. Under optimum conditions, the calibration graph was linear in the concentration range of 10.0–600.0 μg L −1 with a detection limit of 0.61 μg L −1 . The relative standard deviation for ten replicate measurements of 20.0 and 400.0 μg L −1 of Pb were 3.56 and 3.25%, respectively. Comparative studies showed that graphene is superior to other adsorbents including C18 silica, graphitic carbon, and single- and multi-walled carbon nanotubes for the extraction of Pb. The proposed method was successfully applied in the analysis of environmental water and vegetable samples. Good spiked recoveries over the range of 95.3–100.4% were obtained. This work not only proposes a useful method for sample preconcentration, but also reveals the great potential of graphene as an excellent sorbent material in analytical processes.

  10. Determination of lead and nickel in environmental samples by flame atomic absorption spectrometry after column solid-phase extraction on Ambersorb-572 with EDTA

    Energy Technology Data Exchange (ETDEWEB)

    Baytak, Sitki [Department of Chemistry, Faculty of Science and Arts, Harran University, 63100 Sanliurfa (Turkey); Tuerker, A. Rehber [Department of Chemistry, Faculty of Science and Arts, Gazi University, 06500 Ankara (Turkey)]. E-mail: aturker@gazi.edu.tr

    2006-02-28

    Lead and nickel were preconcentrated as their ethylenediaminetetraacedic acid (EDTA) complexes from aqueous sample solutions using a column containing Ambersorb-572 and determined by flame atomic absorption spectrometry (FAAS). pH values, amount of solid phase, elution solution and flow rate of sample solution have been optimized in order to obtain quantitative recovery of the analytes. The effect of interfering ions on the recovery of the analytes has also been investigated. The recoveries of Pb and Ni under the optimum conditions were 99 {+-} 2 and 97 {+-} 3%, respectively, at 95% confidence level. Seventy-five-fold (using 750 mL of sample solution and 10 mL of eluent) and 50-fold (using 500 mL of sample solution and 10 mL of eluent) preconcentration was obtained for Pb and Ni, respectively. Time of analysis is about 4.5 h (for obtaining enrichment factor of 75). By applying these enrichment factors, the analytical detection limits of Pb and Ni were found as 3.65 and 1.42 ng mL{sup -1}, respectively. The capacity of the sorbent was found as 0.17 and 0.21 mmol g{sup -1} for Pb and Ni, respectively. The interferences of some cations, such as Mn{sup 2+}, Co{sup 2+}, Fe{sup 3+}, Al{sup 3+}, Zn{sup 2+}, Cd{sup 2+}, Ca{sup 2+}, Mg{sup 2+}, K{sup +} and Na{sup +} usually present in water samples were also studied. This procedure was applied to the determination of lead and nickel in parsley, green onion, sea water and waste water samples. The accuracy of the procedure was checked by determining Pb and Ni in standard reference tea leaves sample (GBW-07605). The results demonstrated good agreement with the certified values.

  11. Determination of Pb (Lead, Cd (Cadmium, Cr (Chromium, Cu (Copper, and Ni (Nickel in Chinese tea with high-resolution continuum source graphite furnace atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Wen-Si Zhong

    2016-01-01

    Full Text Available The contents of lead, cadmium, chromium, copper, and nickel were determined in 25 tea samples from China, including green, yellow, white, oolong, black, Pu'er, and jasmine tea products, using high-resolution continuum source graphite furnace atomic absorption spectrometry. The methods used for sample preparation, digestion, and quantificational analysis were established, generating satisfactory analytical precisions (represented by relative standard deviations ranging from 0.6% to 2.5% and recoveries (98.91–101.32%. The lead contents in tea leaves were 0.48–10.57 mg/kg, and 80% of these values were below the maximum values stated by the guidelines in China. The contents of cadmium and chromium ranged from 0.01 mg/kg to 0.39 mg/kg and from 0.27 mg/kg to 2.45 mg/kg, respectively, remaining in compliance with the limits stipulated by China's Ministry of Agriculture. The copper contents were 7.73–63.71 mg/kg; only 64% of these values complied with the standards stipulated by the Ministry of Agriculture. The nickel contents ranged from 2.70 mg/kg to 13.41 mg/kg. Consequently, more attention must be paid to the risks of heavy metal contamination in tea. The quantitative method established in this work lays a foundation for preventing heavy metal toxicity in human from drinking tea and will help establish regulations to control the contents of heavy metals in tea.

  12. Combination of dispersive liquid-liquid microextraction with flame atomic absorption spectrometry using microsample introduction for determination of lead in water samples.

    Science.gov (United States)

    Naseri, Mohammad Taghi; Hemmatkhah, Payam; Hosseini, Mohammad Reza Milani; Assadi, Yaghoub

    2008-03-03

    The dispersive liquid-liquid microextraction (DLLME) was combined with the flame atomic absorption spectrometry (FAAS) for determination of lead in the water samples. Diethyldithiophosphoric acid (DDTP), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. A new FAAS sample introduction system was employed for the microvolume nebulization of the non-flammable chlorinated organic extracts. Injection of 20 microL volumes of the organic extract into an air-acetylene flame provided very sensitive spike-like and reproducible signals. Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters include extraction and disperser solvent type as well as their volume, extraction time, salt effect, pH and amount of the chelating agent. Under the optimized conditions, the enrichment factor of 450 was obtained from a sample volume of 25.0 mL. The enhancement factor, calculated as the ratio of the slopes of the calibration graphs with and without preconcentration, which was about 1000. The calibration graph was linear in the range of 1-70 microgL(-1) with a detection limit of 0.5 microgL(-1). The relative standard deviation (R.S.D.) for seven replicate measurements of 5.0 and 50 microgL(-1) of lead were 3.8 and 2.0%, respectively. The relative recoveries of lead in tap, well, river and seawater samples at the spiking level of 20 microgL(-1) ranged from 93.8 to 106.2%. The characteristics of the proposed method were compared with those of the liquid-liquid extraction (LLE), cloud point extraction (CPE), on-line and off-line solid-phase extraction (SPE) as well as co-precipitation, based on bibliographic data. Operation simplicity, rapidity, low cost, high enrichment factor, good repeatability, and low consumption of the extraction solvent at a microliter level are the main advantages of the proposed method.

  13. Combination of dispersive liquid-liquid microextraction with flame atomic absorption spectrometry using microsample introduction for determination of lead in water samples

    International Nuclear Information System (INIS)

    Naseri, Mohammad Taghi; Hemmatkhah, Payam; Hosseini, Mohammad Reza Milani; Assadi, Yaghoub

    2008-01-01

    The dispersive liquid-liquid microextraction (DLLME) was combined with the flame atomic absorption spectrometry (FAAS) for determination of lead in the water samples. Diethyldithiophosphoric acid (DDTP), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. A new FAAS sample introduction system was employed for the microvolume nebulization of the non-flammable chlorinated organic extracts. Injection of 20 μL volumes of the organic extract into an air-acetylene flame provided very sensitive spike-like and reproducible signals. Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters include extraction and disperser solvent type as well as their volume, extraction time, salt effect, pH and amount of the chelating agent. Under the optimized conditions, the enrichment factor of 450 was obtained from a sample volume of 25.0 mL. The enhancement factor, calculated as the ratio of the slopes of the calibration graphs with and without preconcentration, which was about 1000. The calibration graph was linear in the range of 1-70 μg L -1 with a detection limit of 0.5 μg L -1 . The relative standard deviation (R.S.D.) for seven replicate measurements of 5.0 and 50 μg L -1 of lead were 3.8 and 2.0%, respectively. The relative recoveries of lead in tap, well, river and seawater samples at the spiking level of 20 μg L -1 ranged from 93.8 to 106.2%. The characteristics of the proposed method were compared with those of the liquid-liquid extraction (LLE), cloud point extraction (CPE), on-line and off-line solid-phase extraction (SPE) as well as co-precipitation, based on bibliographic data. Operation simplicity, rapidity, low cost, high enrichment factor, good repeatability, and low consumption of the extraction solvent at a microliter level are the main advantages of the proposed method

  14. Investigation of chemical modifiers for the determination of lead in fertilizers and limestone using graphite furnace atomic absorption spectrometry with Zeeman-effect background correction and slurry sampling

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Aline R. [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq–INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Becker, Emilene M.; Dessuy, Morgana B. [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Vale, Maria Goreti R., E-mail: mgrvale@ufrgs.br [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq–INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Welz, Bernhard [Instituto Nacional de Ciência e Tecnologia do CNPq–INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil)

    2014-02-01

    In this work, chemical modifiers in solution (Pd/Mg, NH{sub 4}H{sub 2}PO{sub 4} and NH{sub 4}NO{sub 3}/Pd) were compared with permanent modifiers (Ir and Ru) for the determination of lead in fertilizer and limestone samples using slurry sampling and graphite furnace atomic absorption spectrometry with Zeeman-effect background correction. The analytical line at 283.3 nm was used due to some spectral interference observed at 217.0 nm. The NH{sub 4}H{sub 2}PO{sub 4} was abandoned due to severe spectral interference even at the 283.3-nm line. For Pd/Mg and NH{sub 4}NO{sub 3}/Pd the optimum pyrolysis and atomization temperatures were 900 °C and 1900 °C, respectively. For Ru and Ir, the integrated absorbance signal was stable up to pyrolysis temperatures of 700 °C and 900 °C, respectively, and up to atomization temperature of 1700 °C. The limit of detection (LOD) was 17 ng g{sup −1} using Pd/Mg and 29 ng g{sup −1} using NH{sub 4}NO{sub 3}/Pd. Among the permanent modifiers investigated, the LOD was 22 ng g{sup −1} Pb for Ir and 10 ng g{sup −1} Pb for Ru. The accuracy of the method was evaluated using the certified reference material NIST SRM 695. Although Ru provided lower LOD, which can be attributed to a lower blank signal, only the modifiers in solution showed concordant values of Pb concentration for the NIST SRM 695 and the most of analyzed samples. Moreover, the Pd/Mg modifier provided the highest sensitivity and for this reason it is more suitable for the determination of Pb in fertilizers samples in slurry; besides this it presented a better signal-to-noise ratio than NH{sub 4}NO{sub 3}/Pd. - Highlights: • Lead has been determined in fertilizers using slurry sampling GF AAS. • The mixture of palladium and magnesium nitrates was found to be the ideal chemical modifier. • Calibration could be carried out against aqueous standard solutions. • The proposed method is much faster than the EPA method, which includes sample digestion.

  15. Absorption and translocation of lead by plants: a contribution to the application of the method of radioactive indicators in the investigation of the change of substance

    Energy Technology Data Exchange (ETDEWEB)

    Hevesy, G

    1923-01-01

    The assimilation of lead from lead nitrate solutions by Vicia Faba has been investigated. A radioactive isotope of lead was mixed with the lead nitrate, and the amount of lead taken up was determined after ignition from the radioactive intensity of the ash of the various parts. This method makes possible the determination of exceedingly small amounts of assimilated lead. Whereas 0-3% of the lead is taken up by the root from 200 cc. of a 10/sup -1/ N lead nitrate solution in the course of 24 hours, 60% of the lead content of a 10/sup -1/ N lead nitrate solution in the course of 24 hours, 60% of the lead content of a 10/sup -6/ N solution is taken up in the same time. The leaves show a lead content of only a few hundredths or thousandths of 1% of the amount of lead present in the solution. The assimilated (radioactive) lead can be displaced by introduction of the plant containing lead into another lead solution, whereby inactive lead atoms now take the place of the radioactive ones. From this it follows that the lead is not combined with carbon within the plant, but that it exists in the form of a dissociable salt which is soluble with difficulty. Even after 24 hours, a 10/sup -1/ N solution of a lead salt produces toxic effects on the plant, while more dilute solutions do not. Lead belongs to the least poisonous of the heavy metals. 9 references.

  16. Lead determination at ng/mL level by flame atomic absorption spectrometry using a tantalum coated slotted quartz tube atom trap.

    Science.gov (United States)

    Demirtaş, İlknur; Bakırdere, Sezgin; Ataman, O Yavuz

    2015-06-01

    Flame atomic absorption spectrometry (FAAS) still keeps its importance despite the relatively low sensitivity; because it is a simple and economical technique for determination of metals. In recent years, atom traps have been developed to increase the sensitivity of FAAS. Although the detection limit of FAAS is only at the level of µg/mL, with the use of atom traps it can reach to ng/mL. Slotted quartz tube (SQT) is one of the atom traps used to improve sensitivity. In atom trapping mode of SQT, analyte is trapped on-line in SQT for few minutes using ordinary sample aspiration, followed by the introduction of a small volume of organic solvent to effect the revolatilization and atomization of analyte species resulting in a transient signal. This system is economical, commercially available and easy to use. In this study, a sensitive analytical method was developed for the determination of lead with the help of SQT atom trapping flame atomization (SQT-AT-FAAS). 574 Fold sensitivity enhancement was obtained at a sample suction rate of 3.9 mL/min for 5.0 min trapping period with respect to FAAS. Organic solvent was selected as 40 µL of methyl isobutyl ketone (MIBK). To obtain a further sensitivity enhancement inner surface of SQT was coated with several transition metals. The best sensitivity enhancement, 1650 fold enhancement, was obtained by the Ta-coated SQT-AT-FAAS. In addition, chemical nature of Pb species trapped on quartz and Ta surface, and the chemical nature of Ta on quartz surface were investigated by X-ray photoelectron spectroscopy (XPS) and Raman Spectroscopy. Raman spectrometric results indicate that tantalum is coated on SQT surface in the form of Ta2O5. XPS studies revealed that the oxidation state of Pb in species trapped on both bare and Ta coated SQT surfaces is +2. For the accuracy check, the analyses of standard reference material were performed by use of SCP SCIENCE EnviroMAT Low (EU-L-2) and results for Pb were to be in good agreement with

  17. Temperature-Induced Large Broadening and Blue Shift in the Electronic Band Structure and Optical Absorption of Methylammonium Lead Iodide Perovskite.

    Science.gov (United States)

    Yang, Jia-Yue; Hu, Ming

    2017-08-17

    The power conversion efficiency of hybrid halide perovskite solar cells is profoundly influenced by the operating temperature. Here we investigate the temperature influence on the electronic band structure and optical absorption of cubic CH 3 NH 3 PbI 3 from first-principles by accounting for both the electron-phonon interaction and thermal expansion. Within the framework of density functional perturbation theory, the electron-phonon coupling induces slightly enlarged band gap and strongly broadened electronic relaxation time as temperature increases. The large broadening effect is mainly due to the presence of cation organic atoms. Consequently, the temperature-dependent absorption peak exhibits blue-shift position, decreased amplitude, and broadened width. This work uncovers the atomistic origin of temperature influence on the optical absorption of cubic CH 3 NH 3 PbI 3 and can provide guidance to design high-performance hybrid halide perovskite solar cells at different operating temperatures.

  18. Lead poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Beijers, J A

    1952-01-01

    Three cases of acute lead poisoning of cattle herds via ingestion are reported, and reference is made to several other incidents of lead in both humans and animals. The quantity of lead which was found in the livers of the dead cows varied from 6.5 to 19 mg/kg, while 1160 mg/kg of lead in the liver was found for a young cow which was poisoned experimentally with 5 gms of lead acetate per day; hence, there appears to be great variability in the amounts deposited that can lead to intoxication and death. No evidence was found for a lead seam around the teeth, prophyrinuria, or basophil granules in the erythrocytes during acute or chronic lead poisoning of cattle or horses examined. Reference is made to attempts of finding the boundary line between increased lead absorption and lead intoxication in humans, and an examination of 60 laborers in an offset-printing office containing a great deal of inhalable lead (0.16 to 1.9 mg/cu m air) is reviewed. Physical deviation, basophylic granulation of erythrocytes, increased lead content of the urine, and porphyrinuria only indicate an increased absorption of lead; the use of the term intoxication is justified if, in addition, there are complaints of lack of appetite, constipation, fatigue, abdominal pain, and emaciation.

  19. Determination of trace amounts of lead by chelating ion exchange and on-line preconcentration in flow-injection atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Purohit, Rajesh; Devi, Surekha

    1992-01-01

    Resins synthesized from quinolin-8-ol and resorcinol or hydro-quinone, with furfuraldehyde, formaldehyde or benzaldehyde as cross-linking agent, were used for the preconcentration of nanogram amounts of lead. The rate of exchange and activation energy of lead exchange were calculated. Column separations of lead-copper and lead-zinc did not show any cross-contamination. A continuous flow manifold using resin microcolumns was developed for the preconcentration and determination of lead. (author). 24 refs.; 5 figs.; 3 tabs

  20. The determination of major and some minor constituents in lead zirconate-titanate compositions by x-ray fluorescence and atomic absorption spectrometry

    NARCIS (Netherlands)

    van Willigen, J.H.H.G.; Kruidhof, H.; Dahmen, E.A.M.F.

    1972-01-01

    An accurate X-ray fluorescence spectrometric method is described for the determination of lead, zirconium and titanium in lead zirconate-titanate ceramics. Careful matching of samples and standards by a borax fusion method resulted in a relative standard deviation of about 0.2% for the major

  1. Evaluation of cadmium, lead, copper, iron and zinc in Turkish dietary vegetable oils and olives using electrothermal and flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Acar, O.

    2012-07-01

    The Cd, Pb, Cu, Fe and Zn contents of some edible vegetable oils (soybean, sunflower, flower, nut, corn and olive) and of olives (olive-1, black, green, black crushed with seeds and green crushed with seeds) were determined and evaluated by an electrothermal atomic absorption spectrometer (ETAAS) using an Sc + Ir + NH{sub 4}H{sub 2}PO{sub 4} chemical modifier mixture and flame atomic absorption spectrometer (FAAS) after microwave digestion. The pyrolysis and atomization temperatures of Cd, Pb and Cu in sample solutions with and without the modifier mixture were investigated. The limits of detection (LOD) for analytes found are 0.1, 0.6, 0.9, 15.0 and 12.0 {mu}g L{sup -}1 for Cd, Cu, Pb, Fe and Zn, respectively. The accuracy of the procedure proposed was confirmed by analyzing bovine liver 1577b standard reference material (SRM) and a spiked sample solution. The results of the analytes found were compared with certified and added values. The relative standard deviations of the analytes found were lower than 7% and the percent of recoveries obtained ranges from 96 to 101%. The Sc + Ir + NH{sub 4}H{sub 2}PO{sub 4} mixture proposed was applied for the determination of Cd, Pb and Cu in oils and olives. The results of analytes found in the samples were compared with international and national food quality guidelines as well as with literature values. (Author) 48 refs.

  2. Monitoring content of cadmium, calcium, copper, iron, lead, magnesium and manganese in tea leaves by electrothermal and flame atomizer atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Prkić Ante

    2017-08-01

    Full Text Available Due to the simplicity of tea preparation (pouring hot water onto different dried herbs and its high popularity as a beverage, monitoring and developing a screening methodology for detecting the metal content is very important. The concentrations of Cd, Ca, Cu, Fe, Pb, Mg and Mn in 11 different samples of sage (Salvia officinalis L., linden (Tilia L. and chamomile (Matricaria chamomilla L. purchased at local herbal pharmacy were determined using electrothermal atomizer atomic absorption spectrometry (ETAAS and flame atomizer atomic absorption spectrometry (FAAS. The concentrations determined were: Cd (0.012 – 0.470 mg kg−1, Ca (5209 – 16340 mg kg−1, Cu (22.01 – 33.05 mg kg−1, Fe (114.2 – 440.3 mg kg−1, Pb (0.545 – 2.538 mg kg−1, Mg (2649 – 4325 mg kg−1 and Mn (34.00 – 189.6 mg kg−1. Principal Component Analysis (PCA was applied to identify factors (soil and climate influencing the content of the measured elements in herbal samples. The proposed methodology developed in this work was successfully applied to the detection of metals in herbal samples. The analysis showed that the content of toxic metals in herbal teas was below the maximum dose recommended by the World Health Organization (WHO.

  3. Evaluation of cadmium, lead, copper, iron and zinc in Turkish dietary vegetable oils and olives using electrothermal and flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Acar, O.

    2012-01-01

    The Cd, Pb, Cu, Fe and Zn contents of some edible vegetable oils (soybean, sunflower, flower, nut, corn and olive) and of olives (olive-1, black, green, black crushed with seeds and green crushed with seeds) were determined and evaluated by an electrothermal atomic absorption spectrometer (ETAAS) using an Sc + Ir + NH 4 H 2 PO 4 chemical modifier mixture and flame atomic absorption spectrometer (FAAS) after microwave digestion. The pyrolysis and atomization temperatures of Cd, Pb and Cu in sample solutions with and without the modifier mixture were investigated. The limits of detection (LOD) for analytes found are 0.1, 0.6, 0.9, 15.0 and 12.0 μg L - 1 for Cd, Cu, Pb, Fe and Zn, respectively. The accuracy of the procedure proposed was confirmed by analyzing bovine liver 1577b standard reference material (SRM) and a spiked sample solution. The results of the analytes found were compared with certified and added values. The relative standard deviations of the analytes found were lower than 7% and the percent of recoveries obtained ranges from 96 to 101%. The Sc + Ir + NH 4 H 2 PO 4 mixture proposed was applied for the determination of Cd, Pb and Cu in oils and olives. The results of analytes found in the samples were compared with international and national food quality guidelines as well as with literature values. (Author) 48 refs.

  4. Ion imprinted activated carbon solid-phase extraction coupled to flame atomic absorption spectrometry for selective determination of lead ions in environmental samples

    International Nuclear Information System (INIS)

    Naraghi, Kiyana; Panahi, Homayon Ahmad; Hassani, Amir Hesam; Moniri, Elham

    2014-01-01

    A simple lead ion imprinted sorbent was synthesized by coupling activated carbon with a known metal chelating compound, iminodiacetic acid. The ion imprinted sorbent has been characterized using Fourier transform infrared spectroscopy, elemental analysis and thermogravimetric analysis and subjected for the extraction and determination of trace Pb(II) in environmental water samples. The optimum pH value for sorption of the lead ion was 6.5. The sorption capacity of lead imprinted sorbent was 42.2 mg g"−"1. The chelating imprinted sorbent can be reused for five cycles of sorption-desorption without any significant change in sorption capacity. Compared with non-imprinted polymer particles, the lead ion imprinted sorbent showed high adsorption capacity, significant selectivity, good site accessibility for Pb(II). The equilibrium adsorption data of Pb(II) by modified resin were analyzed by Langmuir, Freundlich, Temkin and Redlich-Peterson models

  5. Ion imprinted activated carbon solid-phase extraction coupled to flame atomic absorption spectrometry for selective determination of lead ions in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Naraghi, Kiyana; Panahi, Homayon Ahmad; Hassani, Amir Hesam [Islamic Azad University, Tehran (Korea, Republic of); Moniri, Elham [Islamic Azad University, Varamin (Iran, Islamic Republic of)

    2014-10-15

    A simple lead ion imprinted sorbent was synthesized by coupling activated carbon with a known metal chelating compound, iminodiacetic acid. The ion imprinted sorbent has been characterized using Fourier transform infrared spectroscopy, elemental analysis and thermogravimetric analysis and subjected for the extraction and determination of trace Pb(II) in environmental water samples. The optimum pH value for sorption of the lead ion was 6.5. The sorption capacity of lead imprinted sorbent was 42.2 mg g{sup −1}. The chelating imprinted sorbent can be reused for five cycles of sorption-desorption without any significant change in sorption capacity. Compared with non-imprinted polymer particles, the lead ion imprinted sorbent showed high adsorption capacity, significant selectivity, good site accessibility for Pb(II). The equilibrium adsorption data of Pb(II) by modified resin were analyzed by Langmuir, Freundlich, Temkin and Redlich-Peterson models.

  6. Developmental immunotoxicology of lead

    International Nuclear Information System (INIS)

    Dietert, Rodney R.; Lee, Ji-Eun; Hussain, Irshad; Piepenbrink, Michael

    2004-01-01

    The heavy metal, lead, is a known developmental immunotoxicant that has been shown to produce immune alterations in humans as well as other species. Unlike many compounds that exert adverse immune effects, lead exposure at low to moderate levels does not produce widespread loss of immune cells. In contrast, changes resulting from lead exposure are subtle at the immune cell population level but, nevertheless, can be functionally dramatic. A hallmark of lead-induced immunotoxicity is a pronounced shift in the balance in T helper cell function toward T helper 2 responses at the expense of T helper 1 functions. This bias alters the nature and range of immune responses that can be produced thereby influencing host susceptibility to various diseases. Immunotoxic responses to lead appear to differ across life stages not only quantitatively with regard to dose response, but also qualitatively in terms of the spectrum of immune alterations. Experimental studies in several lab animal species suggest the latter stages of gestation are a period of considerable sensitivity for lead-induced immunotoxicity. This review describes the basic characteristics of lead-induced immunotoxicity emphasizing experimental animal results. It also provides a framework for the consideration of toxicant exposure effects across life stages. The existence of and probable basis for developmental windows of immune hyper-susceptibility are presented. Finally, the potential for lead to serve as a perinatal risk factor for childhood asthma as well as other diseases is considered

  7. Influence of citric acid as chemical modifier for lead determination in dietary calcium supplement samples by graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Cezar Paz de Mattos, Julio; Medeiros Nunes, Adriane; Figueiredo Martins, Ayrton; Luiz Dressler, Valderi; Marlon de Moraes Flores, Erico

    2005-01-01

    Citric acid was used as a chemical modifier for Pb determination by graphite furnace atomic absorption spectrometry in dietary supplement samples (calcium carbonate, dolomite and oyster shell samples) and its efficiency was compared to the use of palladium. Pyrolysis and atomization curves were established without use of chemical modifier, with the addition of 20, 100 and 200 μg of citric acid, and with 3 μg of palladium. The citric acid modifier made possible the interference-free Pb determination in the presence of high concentrations of Ca and Mg nitrates. Acid sample digestion involving closed vessels (microwave-assisted and conventional heating) and acid attack using polypropylene vessels at room temperature were compared. All digestion procedures presented similar results for calcium carbonate and dolomite samples. However, for oyster shell samples accurate results were obtained only with the use of closed vessel systems. Analyte addition and matrix-matched standards were used for calibration. The characteristic mass for Pb using citric acid and palladium were 16 and 25 pg, respectively. The relative standard deviation (RSD) was always less than 5% when citric acid was used. The relative and absolute limits of detection were 0.02 μg g -1 and 8 pg with citric acid and 0.1 μg g -1 and 44 pg with the Pd modifier, respectively (n = 10, 3σ). The recovery of Pb in spiked calcium supplement samples (10 μg l -1 ) was between 98% and 105%. With the use of 100 μg of citric acid as chemical modifier, problems such as high background absorption and high RSD values were minimized in comparison to the addition of 3 μg of palladium

  8. Solid phase extraction method for the determination of lead, nickel, copper and manganese by flame atomic absorption spectrometry using sodium bispiperdine-1,1'-carbotetrathioate (Na-BPCTT) in water samples

    International Nuclear Information System (INIS)

    Rekha, D.; Suvardhan, K.; Kumar, J. Dilip; Subramanyam, P.; Prasad, P. Reddy; Lingappa, Y.; Chiranjeevi, P.

    2007-01-01

    A novel column solid phase extraction procedure was developed for the determination of lead, nickel, copper and manganese in various water samples by flame atomic absorption spectrometry (FAAS) after preconcentration on sodium bispiperdine-1,1'-carbotetrathioate (Na-BPCTT) supported by Amberlite XAD-7. The sorbed element was subsequently eluted with 1 M nitric acid and the acid eluates are analysed by Flame atomic absorption spectrometry (FAAS). Various parameters such as pH, amount of adsorbent, eluent type and volume, flow-rate of the sample solution, volume of the sample solution and matrix interference effect on the retention of the metal ions have been studied. The optimum pH for the sorption of above mentioned metal ions was about 6.0 ± 0.2. The loading capacity of adsorbent for Pb, Cu, Ni and Mn were found to 28, 26, 22 and 20 x 10 -6 g/mL, respectively. The recoveries of lead, copper, nickel and manganese under optimum conditions were found to be 96.7-99.2 at the 95% confident level. The limit of detection was 3.0, 3.2, 2.8 and 3.6 x 10 -6 g/mL for lead, copper, nickel and manganese, respectively by applying a preconcentration factor 50. The proposed enrichment method was applied for metal ions in various water samples. The results were obtained are good agreement with reported method

  9. Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Olmedo, P.; Pla, A.; Hernandez, A.F.; Lopez-Guarnido, O.; Rodrigo, L.; Gil, F.

    2010-01-01

    For biological monitoring of heavy metal exposure in occupational toxicology, usually whole blood and urine samples are the most widely used and accepted matrix to assess internal xenobiotic exposure. Hair samples and saliva are also of interest in occupational and environmental health surveys but procedures for the determination of metals in saliva and hair are very scarce and to our knowledge there is no validation of a method to quantify Cr, Cd, Mn, Ni and Pb in four different human biological materials (whole blood, urine, saliva and axilary hair) by electrothermal atomization atomic absorption spectrometry (ETAAS). In the present study, quantification methods for the determination of Cr, Cd, Mn, Ni and Pb in whole blood, urine, saliva and axilary hair were validated according to the EU common standards. Pyrolisis and atomization temperatures have been determined. The main parameters evaluated were: detection and quantification limits, linearity range, repeatability, reproducibility, recovery and uncertainty. Accuracy of the methods was tested with the whole blood, urine and hair certified reference materials and recoveries of the spiked samples were acceptable ranged from 96.3 to 107.8%.

  10. Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Olmedo, P.; Pla, A.; Hernandez, A.F.; Lopez-Guarnido, O.; Rodrigo, L. [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain); Gil, F., E-mail: fgil@ugr.es [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain)

    2010-02-05

    For biological monitoring of heavy metal exposure in occupational toxicology, usually whole blood and urine samples are the most widely used and accepted matrix to assess internal xenobiotic exposure. Hair samples and saliva are also of interest in occupational and environmental health surveys but procedures for the determination of metals in saliva and hair are very scarce and to our knowledge there is no validation of a method to quantify Cr, Cd, Mn, Ni and Pb in four different human biological materials (whole blood, urine, saliva and axilary hair) by electrothermal atomization atomic absorption spectrometry (ETAAS). In the present study, quantification methods for the determination of Cr, Cd, Mn, Ni and Pb in whole blood, urine, saliva and axilary hair were validated according to the EU common standards. Pyrolisis and atomization temperatures have been determined. The main parameters evaluated were: detection and quantification limits, linearity range, repeatability, reproducibility, recovery and uncertainty. Accuracy of the methods was tested with the whole blood, urine and hair certified reference materials and recoveries of the spiked samples were acceptable ranged from 96.3 to 107.8%.

  11. Direct extraction of lead (II) from untreated human blood serum using restricted access carbon nanotubes and its determination by atomic absorption spectrometry.

    Science.gov (United States)

    Barbosa, Valéria Maria Pereira; Barbosa, Adriano Francisco; Bettini, Jefferson; Luccas, Pedro Orival; Figueiredo, Eduardo Costa

    2016-01-15

    Oxidized carbon nanotubes were covered with layers of bovine serum albumin to result in so-called restricted-access carbon nanotubes (RACNTs). This material can extract Pb(2+) ions directly from untreated human blood serum while excluding all the serum proteins. The RACNTs have a protein exclusion capacity of almost 100% and a maximum Pb(2+) adsorption capacity of 34.5mg g(-1). High resolution transmission electron microscopy, scanning transmission electron microscopy and energy dispersive spectroscopy were used to confirm the BSA layer and Pb(2+) adsorption sites. A mini-column filled with RACNTs was used in an on-line solid phase extraction system coupled to a thermospray flame furnace atomic absorption spectrometry. At optimized experimental conditions, the method has a detection limit as low as 2.1µg L(-1), an enrichment factor of 5.5, and inter- and intra-day precisions (expressed as relative standard deviation) of <8.1%. Recoveries of the Pb(2+) spiked samples ranged from 89.4% to 107.3% for the extraction from untreated human blood serum. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Cloud point extraction for the determination of lead and cadmium in urine by graphite furnace atomic absorption spectrometry with multivariate optimization using Box-Behnken design

    International Nuclear Information System (INIS)

    Maranhao, Tatiane de A; Martendal, Edmar; Borges, Daniel L.G.; Carasek, Eduardo; Welz, Bernhard; Curtius, Adilson J.

    2007-01-01

    Cloud point extraction (CPE) is proposed as a pre-concentration procedure for the determination of Pb and Cd in undigested urine by graphite furnace atomic absorption spectrometry (GF AAS). Aliquots of 0.5 mL urine were acidified with HCl and the chelating agent ammonium O,O-diethyl dithiophosphate (DDTP) was added along with the non-ionic surfactant Triton X-114 at the optimized concentrations. Phase separation was achieved by heating the mixture to 50 deg. C for 15 min. The surfactant-rich phase was analyzed by GF AAS, employing the optimized pyrolysis temperatures of 900 deg. C for Pb and 800 deg. C for Cd, using a graphite tube with a platform treated with 500 μg Ru as permanent modifier. The reagent concentrations for CPE (HCl, DDTP and Triton X-114) were optimized using a Box-Behnken design. The response surfaces and the optimum values were very similar for aqueous solutions and for the urine samples, demonstrating that aqueous standards submitted to CPE could be used for calibration. Detection limits of 40 and 2 ng L -1 for Pb and Cd, respectively, were obtained along with an enhancement factor of 16 for both analytes. Three control urine samples were analyzed using this approach, and good agreement was obtained at a 95% statistical confidence level between the certified and determined values. Five real samples have also been analyzed before and after spiking with Pb and Cd, resulting in recoveries ranging from 97 to 118%

  13. Evaluation of cadmium, lead, copper, iron and zinc in Turkish dietary vegetable oils and olives using electrothermal and flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Acar, Orhan

    2012-10-01

    Full Text Available The Cd, Pb, Cu, Fe and Zn contents of some edible vegetable oils (soybean, sunflower, flower, nut, corn and olive and of olives (olive-1, black, green, black crushed with seeds and green crushed with seeds were determined and evaluated by an electrothermal atomic absorption spectrometer (ETAAS using an Sc + Ir + NH4H2PO4 chemical modifier mixture and flame atomic absorption spectrometer (FAAS after microwave digestion. The pyrolysis and atomization temperatures of Cd, Pb and Cu in sample solutions with and without the modifier mixture were investigated. The limits of detection (LOD for analytes found are 0.1, 0.6, 0.9, 15.0 and 12.0 μg L–1 for Cd, Cu, Pb, Fe and Zn, respectively. The accuracy of the procedure proposed was confirmed by analyzing bovine liver 1577b standard reference material (SRM and a spiked sample solution. The results of the analytes found were compared with certified and added values. The relative standard deviations of the analytes found were lower than 7% and the percent of recoveries obtained ranges from 96 to 101%. The Sc + Ir + NH4H2PO4 mixture proposed was applied for the determination of Cd, Pb and Cu in oils and olives. The results of analytes found in the samples were compared with international and national food quality guidelines as well as with literature values.

    Se han determinado los metales Cd, Cu, Pb, Fe y Zn en aceites vegetales comestibles (soja, girasol, flores, nueces, maíz y aceite de oliva y aceitunas (aceitunas-1, negra, verde, negra machacadas con semillas y verde machacadas con semillas mediante espectrometría de absorción atómica electrotérmica (ETAAS utilizando como modificador químico la mezcla Sc + Ir + NH4H2PO4 y mediante espectrometría de absorción atómica de llama (FAAS tras digestión con microondas. Se estudiaron las temperaturas de pirólisis y atomización para Cd

  14. Working towards accreditation by the International Standards Organization 15189 Standard: how to validate an in-house developed method an example of lead determination in whole blood by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Garcia Hejl, Carine; Ramirez, Jose Manuel; Vest, Philippe; Chianea, Denis; Renard, Christophe

    2014-09-01

    Laboratories working towards accreditation by the International Standards Organization (ISO) 15189 standard are required to demonstrate the validity of their analytical methods. The different guidelines set by various accreditation organizations make it difficult to provide objective evidence that an in-house method is fit for the intended purpose. Besides, the required performance characteristics tests and acceptance criteria are not always detailed. The laboratory must choose the most suitable validation protocol and set the acceptance criteria. Therefore, we propose a validation protocol to evaluate the performance of an in-house method. As an example, we validated the process for the detection and quantification of lead in whole blood by electrothermal absorption spectrometry. The fundamental parameters tested were, selectivity, calibration model, precision, accuracy (and uncertainty of measurement), contamination, stability of the sample, reference interval, and analytical interference. We have developed a protocol that has been applied successfully to quantify lead in whole blood by electrothermal atomic absorption spectrometry (ETAAS). In particular, our method is selective, linear, accurate, and precise, making it suitable for use in routine diagnostics.

  15. Determination of cadmium and lead in urine samples after dispersive solid–liquid extraction on multiwalled carbon nanotubes by slurry sampling electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Álvarez Méndez, J.; Barciela García, J.; García Martín, S.; Peña Crecente, R.M.; Herrero Latorre, C., E-mail: carlos.herrero@usc.es

    2015-04-01

    A new method for the determination of Cd and Pb in urine samples has been developed. The method involves dispersive solid-phase extraction (DSPE), slurry sampling (SS), and subsequent electrothermal atomic absorption spectrometry (ETAAS). Oxidized multiwalled carbon nanotubes (MWCNTs) were used as the sorbent material. The isolated MWCNT/analyte aggregates were treated with nitric acid to form a slurry and both metals were determined directly by injecting the slurry into the ETAAS-atomizer. The parameters that influence the adsorption of the metals on MWCNTs in the DSPE process, the formation and extraction of the slurry, and the ETAAS conditions were studied by different factorial design strategies. The detection and quantification limits obtained for Cd under optimized conditions were 9.7 and 32.3 ng L{sup −1}, respectively, and for Pb these limits were 0.13 and 0.43 μg L{sup −1}. The preconcentration factors achieved were 3.9 and 5.4. The RSD values (n = 10) were less than 4.1% and 5.9% for Cd and Pb, respectively. The accuracy of the method was assessed in recovery studies, with values in the range 96–102% obtained for Cd and 97–101% for Pb. In addition, the analysis of certified reference materials gave consistent results. The DSPE–SS–ETAAS method is a novel and useful strategy for the determination of Pb and Cd at low levels in human urine samples. The method is sensitive, fast, and free of matrix interferences, and it avoids the tedious and time-consuming on-column adsorption and elution steps associated with commonly used SPE procedures. The proposed method was used to determine Cd and Pb in urine samples of unexposed healthy people and satisfactory results were obtained. - Highlights: • Cd and Pb determination based on the combination of DSP, SS and ETAAS • Urine matrix was eliminated using DSPE based on multiwalled carbon nanotubes. • Slurry sampling technique permitted the direct injection of sample into the ETAAS atomizer.

  16. Determination of Lead and Cadmium in environment materials from the planned area for a nuclear power plant by atomic absorption spectrophotometry method

    International Nuclear Information System (INIS)

    Supriyanto, C; Djokowidodo; Isyuniarto; Heri-Wahyudi; Ashar-Andrianto

    1996-01-01

    The determination of Pb and Cd in environment materials (water, cassava leaves and soil) have been done by atomic absorption spectrophotometry method, The determination of Pb and Cd was done with graphite tube atomizer (GTA) method at optimum condition : wavelength for Pb and Cd 217.0 nm and 228.8 nm; temperature/time ashing 550 o C/37 sec and 350 o C/52 sec; temperature/time atomizing 2000 o C/5.1 sec and 2000 o C/5.2 sec. Modifier for Pb was 3 μL of Mg 1000 μg/ml and Cd was 2 μL of Pd 2000 μg/ml. The content Pb in Spalun river, Hulu Putih river and sea water Lemah Abang was 0.94 ± 0.03; 0.91± 0.02; 4.71 ± 0.26 ng/ml respectively; the Cd content was 1.23 ± 0.11; 0.48 ± 0.01; 0.55 ± 0.01 ng/ml respectively. The Pb dan Cd content in cassava leaves was 163.24 ± 3.72 and 18.45 ± 1.46 ng/g respectively, while the Pb content in soil at the depth variation 0 - 5, 5 - 10, 10 - 20 and 20 - 30 Cm was 2.35 ± 0.15; 2.86 ± 0.16; 1.97 ± 0.11 and 2.19 ± 0.06 μg/g respectively and the Cd content was 43.67 ± 1.52; 37.01 ± 1.01; 31.68 ± 0.17 and 36.97 ± 1.63 ng/g respectively. SRM Citrous leaves from NSB and SRM Soil 7 from the IAEA local used to control the quality of the analyzed method. The Pb, Cd content in SRM was in accordance with the value in the certified legend

  17. Lead ultra-trace on-line preconcentration and determination using selective solid phase extraction and electrothermal atomic absorption spectrometry: applications in seawaters and biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Vereda Alonso, E.; Siles Cordero, M.T.; Garcia de Torres, A.; Cano Pavon, J.M. [University of Malaga, Department of Analytical Chemistry Faculty of Sciences, Malaga (Spain)

    2006-08-15

    In this work, a new chelating resin [1,5-bis (2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide immobilised on aminopropyl-controlled pore glass (550 Aa; PSTH-cpg) was synthesised and packed in a microcolumn which replaced the sample tip of the autosampler arm. The system was applied to the preconcentration of lead. When microliters of 10% HNO{sub 3}, which acts as elution agent, pass through the microcolumn, the preconcentrated Pb(II) is eluted and directly deposited in a tungsten-rhodium coated graphite tube. With the use of the separation and preconcentration step and the permanent modifiers, the analytical characteristics of the technique were improved. The proposed method has a linear calibration range from 0.012 to 10 ng ml{sup -1} of lead. At a sample frequency of 36 h{sup -1} with a 90 s preconcentration time, the enrichment factor was 20.5, the detection and determination limits were 0.012 and 0.14 ng ml{sup -1}, respectively and the precision, expressed as relative standard deviation, was 3.2% (at 1 ng ml{sup -1}). Results from the determination of Pb in biological certified reference materials were in agreement with the certified values. Seawaters and other biological samples were analysed too. (orig.)

  18. Calcium absorption

    International Nuclear Information System (INIS)

    Carlmark, B.; Reizenstein, P.; Dudley, R.A.

    1976-01-01

    The methods most commonly used to measure the absorption and retention of orally administered calcium are reviewed. Nearly all make use of calcium radioisotopes. The magnitude of calcium absorption and retention depends upon the chemical form and amount of calcium administered, and the clinical and nutritional status of the subject; these influences are briefly surveyed. (author)

  19. Absorption studies

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Absorption studies were once quite popular but hardly anyone does them these days. It is easier to estimate the blood level of the nutrient directly by radioimmunoassay (RIA). However, the information obtained by estimating the blood levels of the nutrients is not the same that can be obtained from the absorption studies. Absorption studies are primarily done to find out whether some of the essential nutrients are absorbed from the gut or not and if they are absorbed, to determine how much is being absorbed. In the advanced countries, these tests were mostly done to detect pernicious anaemia where vitamin B 12 is not absorbed because of the lack of the intrinsic factor in the stomach. In the tropical countries, ''malabsorption syndrome'' is quire common. In this condition, several nutrients like fat, folic acid and vitamin B 12 are not absorbed. It is possible to study absorption of these nutrients by radioisotopic absorption studies

  20. Optical absorption enhancement in NH2CH=NH2PbI3 lead halide perovskite solar cells with nanotextures

    Science.gov (United States)

    Xie, Ziang; Sun, Shuren; Xie, Xixi; Hou, Ruixiang; Xu, Wanjin; Li, Yanping; Qin, G. G.

    2018-01-01

    This article reports, for the first time to our knowledge, that the power conversion efficiencies (PCEs) of planar NH2CH=NH2PbI3 (FAPbI3) lead halide perovskite solar cells (SCs) can be largely improved by fabricating nanotextures on the SC surface. Four kinds of nanotextures are investigated and compared with each other: column hollow (CLH) nanoarrays, cone hollow (CNH) nanoarrays, square prism hollow (SPH) nanoarrays, and pyramid hollow (PYH) nanoarrays. Compared with the PCEs of the planar SCs with the same layer depth d, it is found that when d is in the range of 125-500 nm and when the array period, as well as the filling fraction of the nanotexture, are optimized, the ultimate efficiency increased 29%-50% for the CLH and SPH textured FAPbI3 SCs relative to the planar ones, and 20%-41% for the CNH and PYH textured FAPbI3 SCs relative to the planar ones. When d < 250 nm, the optimized ultimate efficiencies of the CLH and SPH textured FAPbI3 SCs with optimized nanotextures are higher than those of the CNH and PYH ones, and vice versa. The reasons why fabricating nanotextures on SC surfaces can largely improve the PCE of the FAPbI3 SCs are discussed.

  1. Geospatial Absorption and Regional Effects

    Directory of Open Access Journals (Sweden)

    IOAN MAC

    2009-01-01

    Full Text Available The geospatial absorptions are characterized by a specific complexity both in content and in their phenomenological and spatial manifestation fields. Such processes are differentiated according to their specificity to pre-absorption, absorption or post-absorption. The mechanisms that contribute to absorption are extremely numerous: aggregation, extension, diffusion, substitution, resistivity (resilience, stratification, borrowings, etc. Between these mechanisms frequent relations are established determining an amplification of the process and of its regional effects. The installation of the geographic osmosis phenomenon in a given territory (a place for example leads to a homogenization of the geospatial state and to the installation of the regional homogeneity.

  2. Influence of PbCl2 content in PbI2 solution of DMF on the absorption, crystal phase, morphology of lead halide thin films and photovoltaic performance in planar perovskite solar cells

    International Nuclear Information System (INIS)

    Wang, Mao; Shi, Chengwu; Zhang, Jincheng; Wu, Ni; Ying, Chao

    2015-01-01

    In this paper, the influence of PbCl 2 content in PbI 2 solution of DMF on the absorption, crystal phase and morphology of lead halide thin films was systematically investigated and the photovoltaic performance of the corresponding planar perovskite solar cells was evaluated. The result revealed that the various thickness lead halide thin film with the small sheet-like, porous morphology and low crystallinity can be produced by adding PbCl 2 powder into PbI 2 solution of DMF as a precursor solution. The planar perovskite solar cell based on the 300-nm-thick CH 3 NH 3 PbI 3−x Cl x thin film by the precursor solution with the mixture of 0.80 M PbI 2 and 0.20 M PbCl 2 exhibited the optimum photoelectric conversion efficiency of 10.12% along with an open-circuit voltage of 0.93 V, a short-circuit photocurrent density of 15.70 mA cm −2 and a fill factor of 0.69. - Graphical abstract: The figure showed the surface and cross-sectional SEM images of lead halide thin films using the precursor solutions: (a) 0.80 M PbI 2 , (b) 0.80 M PbI 2 +0.20 M PbCl 2 , (c) 0.80 M PbI 2 +0.40 M PbCl 2 , and (d) 0.80 M PbI 2 +0.60 M PbCl 2 . With the increase of the PbCl 2 content in precursor solution, the size of the lead halide nanosheet decreased and the corresponding thin films gradually turned to be porous with low crystallinity. - Highlights: • Influence of PbCl 2 content on absorption, crystal phase and morphology of thin film. • Influence of perovskite film thickness on photovoltaic performance of solar cell. • Lead halide thin film with small sheet-like, porous morphology and low crystallinity. • Planar solar cell with 300 nm-thick perovskite thin film achieved PCE of 10.12%.

  3. Folate absorption

    International Nuclear Information System (INIS)

    Baker, S.J.

    1976-01-01

    Folate is the generic term given to numerous compounds of pteroic acid with glutamic acid. Knowledge of absorption is limited because of the complexities introduced by the variety of compounds and because of the inadequacy of investigational methods. Two assay methods are in use, namely microbiological and radioactive. Techniques used to study absorption include measurement of urinary excretion, serum concentration, faecal excretion, intestinal perfusion, and haematological response. It is probably necessary to test absorption of both pteroylmonoglutamic acid and one or more polyglutamates, and such tests would be facilitated by availability of synthesized compounds labelled with radioactive tracers at specifically selected sites. (author)

  4. Flame atomic absorption spectrometric determination of zinc, nickel, iron and lead in different matrixes after solid phase extraction on sodium dodecyl sulfate (SDS)-coated alumina as their bis (2-hydroxyacetophenone)-1, 3-propanediimine chelates

    International Nuclear Information System (INIS)

    Ghaedi, M.; Tavallali, H.; Shokrollahi, A.; Zahedi, M.; Montazerozohori, M.; Soylak, M.

    2009-01-01

    A sensitive and simple solid phase extraction method for the simultaneous determination of trace and toxic metals in food samples has been reported. The method is based on the adsorption of zinc, nickel, iron and lead on sodium dodecyl sulfate (SDS)-coated alumina, which is also chelated with bis (2-hydroxyacetophenone)-1, 3-propanediimine (BHAPN). The retained analyte ions on modified solid phase were eluted using 8 mL of 4 mol L -1 HNO 3 . The analyte determinations were carried out by flame atomic absorption spectrometry. The influences of some metal ions and anions on the recoveries of understudy analyte ions were investigated. The proposed method has been successfully applied for the evaluation of these trace and toxic metals in some traditional food samples from Iran.

  5. [A comparative study of cadmium, lead, mercury, arsenic, selenium, manganese, copper and zinc in brown rice and fish by inductively coupled plasma-mass spectrometry (ICP-MS) and atomic absorption spectrometry].

    Science.gov (United States)

    Oshima, Harumi; Ueno, Eiji; Saito, Isao; Matsumoto, Hiroshi

    2004-10-01

    A study was conducted to evaluate the applicability of ICP-MS techniques for determination of metals in brown rice and fish. Cadmium, lead, mercury, arsenic, selenium, manganese, copper and zinc were determined by this method. An open digestion with nitric acid (Method A) and a rapid open digestion with nitric acid and hydrochloric acid (Method B) were used to solubilize analytes in samples, and these procedures were followed by ICP-MS analysis. Recovery of certified elements from standard reference materials by Method A and Method B ranged from 92 to 110% except for mercury (70 to 100%). Analytical results of brown rice and fish samples obtained by this ICP-MS agreed with those obtained by atomic absorption spectrometry (AAS). The results of this study demonstrate that quadrupole ICP-MS provides precise and accurate measurements of the elements tested in brown rice and fish samples.

  6. Study on solid phase extraction and graphite furnace atomic absorption spectrometry for the determination of nickel, silver, cobalt, copper, cadmium and lead with MCI GEL CHP 20Y as sorbent

    International Nuclear Information System (INIS)

    Yang Guangyu; Fen Weibo; Lei Chun; Xiao Weilie; Sun Handong

    2009-01-01

    A solid phase extraction and graphite furnace atomic absorption spectrometry (GFAAS) for the determination of nickel, silver, cobalt, copper, cadmium and lead with MCI GEL CHP 20Y as sorbent was studied. Trace amounts of chromium, nickel, silver, cobalt, copper, cadmium and lead were reacted with 2-(2-quinolinil-azo)-4-methyl-1,3-dihydroxidobenzene (QAMDHB) followed by adsorption onto MCI GEL CHP 20Y solid phase extraction column, and 1.0 mol L -1 HNO 3 was used as eluent. The metal ions in 300 mL solution can be concentrated to 1.0 mL, representing an enrichment factor of 300 was achieved. The recoveries of analytes at pH 8.0 with 1.0 g of resin were greater than 95% without interference from alkaline, earth alkaline and some metal ions. When detected with graphite furnace atomic absorption spectrometry, the detection limits in the original samples were 1.4 ng L -1 for Cr(III), 1.0 ng L -1 for Ni(II), 0.85 ng L -1 for Ag(I), 1.2 ng L -1 for Co(II), 1.0 ng L -1 for Cu(II), 1.2 ng L -1 for Cd(II) and 1.3 ng L -1 for Pb(II). The validation of the procedure was performed by the analysis of the certified standard reference materials, and the presented procedure was applied to the determination of analytes in biological, water and soil samples with good results (recoveries range from 89 to 104%, and R.S.D.% lower than 3.2%. The results agreed with the standard value or reference method)

  7. Cloud point extraction of copper, lead, cadmium, and iron using 2,6-diamino-4-phenyl-1,3,5-triazine and nonionic surfactant, and their flame atomic absorption spectrometric determination in water and canned food samples.

    Science.gov (United States)

    Citak, Demirhan; Tuzen, Mustafa

    2012-01-01

    A cloud point extraction procedure was optimized for the separation and preconcentration of lead(II), cadmium(II), copper(II), and iron(III) ions in various water and canned food samples. The metal ions formed complexes with 2,6-diamino-4-phenyl-1,3,5-triazine that were extracted by surfactant-rich phases in the nonionic surfactant Triton X-114. The surfactant-rich phase was diluted with 1 M HNO3 in methanol prior to its analysis by flame atomic absorption spectrometry. The parameters affecting the extraction efficiency of the proposed method, such as sample pH, complexing agent concentration, surfactant concentration, temperature, and incubation time, were optimized. LOD values based on three times the SD of the blank (3Sb) were 0.38, 0.48, 1.33, and 1.85 microg/L for cadmium(II), copper(II), lead(II), and iron(III) ions, respectively. The precision (RSD) of the method was in the 1.86-3.06% range (n=7). Validation of the procedure was carried out by analysis of National Institute of Standards and Technology Standard Reference Material (NIST-SRM) 1568a Rice Flour and GBW 07605 Tea. The method was applied to water and canned food samples for determination of metal ions.

  8. On-line separation and preconcentration of lead(II) by solid-phase extraction using activated carbon loaded with xylenol orange and its determination by flame atomic absorption spectrometry.

    Science.gov (United States)

    Ensafi, Ali A; Shiraz, A Zendegi

    2008-02-11

    Activated carbon loaded with xylenol orange in a mini-column was used for the highly selective separation and preconcentration of Pb(II) ions. An on-line system for enrichment and the determination of Pb(II) was carried out on flame atomic absorption spectrometry. The conditions of preconcentration and quantitative recovery of Pb(II) from diluted solution, such as pH of aqueous phase, amount of the sorbent, volume of the solutions and flow variables were studied as well as effect of potential interfering ions. Under the optimum conditions, Pb(II) in an aqueous sample was concentrated about 200-fold and the detection limit was 0.4 ng mL(-1) Pb(II). The adsorption capacity of the solid phase was 0.20mg of lead per one gram of the modified activated carbon. The modified activated carbon is stable for several treatments of sample solutions without the need for using any chemical reagent. The recovery of lead(II) from river water, waste water, tap water, and in the following reference materials: SRM 2711 Montana soil and GBW-07605 tea were obtained in the range of 97-104% by the proposed method.

  9. On-line separation and preconcentration of lead(II) by solid-phase extraction using activated carbon loaded with xylenol orange and its determination by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Ensafi, Ali A.; Shiraz, A. Zendegi

    2008-01-01

    Activated carbon loaded with xylenol orange in a mini-column was used for the highly selective separation and preconcentration of Pb(II) ions. An on-line system for enrichment and the determination of Pb(II) was carried out on flame atomic absorption spectrometry. The conditions of preconcentration and quantitative recovery of Pb(II) from diluted solution, such as pH of aqueous phase, amount of the sorbent, volume of the solutions and flow variables were studied as well as effect of potential interfering ions. Under the optimum conditions, Pb(II) in an aqueous sample was concentrated about 200-fold and the detection limit was 0.4 ng mL -1 Pb(II). The adsorption capacity of the solid phase was 0.20 mg of lead per one gram of the modified activated carbon. The modified activated carbon is stable for several treatments of sample solutions without the need for using any chemical reagent. The recovery of lead(II) from river water, waste water, tap water, and in the following reference materials: SRM 2711 Montana soil and GBW-07605 tea were obtained in the range of 97-104% by the proposed method

  10. On-line separation and preconcentration of lead(II) by solid-phase extraction using activated carbon loaded with xylenol orange and its determination by flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ensafi, Ali A. [College of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)], E-mail: Ensafi@cc.iut.ac.ir; Shiraz, A. Zendegi [College of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)

    2008-02-11

    Activated carbon loaded with xylenol orange in a mini-column was used for the highly selective separation and preconcentration of Pb(II) ions. An on-line system for enrichment and the determination of Pb(II) was carried out on flame atomic absorption spectrometry. The conditions of preconcentration and quantitative recovery of Pb(II) from diluted solution, such as pH of aqueous phase, amount of the sorbent, volume of the solutions and flow variables were studied as well as effect of potential interfering ions. Under the optimum conditions, Pb(II) in an aqueous sample was concentrated about 200-fold and the detection limit was 0.4 ng mL{sup -1} Pb(II). The adsorption capacity of the solid phase was 0.20 mg of lead per one gram of the modified activated carbon. The modified activated carbon is stable for several treatments of sample solutions without the need for using any chemical reagent. The recovery of lead(II) from river water, waste water, tap water, and in the following reference materials: SRM 2711 Montana soil and GBW-07605 tea were obtained in the range of 97-104% by the proposed method.

  11. Determination of lead at trace levels in mussel and sea water samples using vortex assisted dispersive liquid-liquid microextraction-slotted quartz tube-flame atomic absorption spectrometry.

    Science.gov (United States)

    Erarpat, Sezin; Özzeybek, Gözde; Chormey, Dotse Selali; Bakırdere, Sezgin

    2017-12-01

    In this study, dispersive liquid-liquid microextraction (DLLME) and slotted quartz tube (SQT) were coupled to flame atomic absorption spectrometry (FAAS) to increase the sensitivity of lead. Conditions such as the formation of the lead-dithizone complex, efficiency of the DLLME method and the output of the SQT were systematically optimized to improve the detection limit for the analyte. The conventional FAAS system was improved upon by about 3.0 times with SQT-FAAS, 32 times with DLLME-FAAS and 142 times with DLLME-SQT-FAAS. The method was applicable over a wide linear range (10-500 μg L -1 ). The limit of detection (LOD) determined by DLLME-SQT-FAAS for seawater and mussel were 2.7 μg L -1 and 270 μg kg -1 , respectively. The percent recoveries obtained for mussel and seawater samples (spiked at 20 and 50 μg L -1 ) were 95-96% and 98-110%, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Narrative absorption

    DEFF Research Database (Denmark)

    Narrative Absorption brings together research from the social sciences and Humanities to solve a number of mysteries: Most of us will have had those moments, of being totally absorbed in a book, a movie, or computer game. Typically we do not have any idea about how we ended up in such a state. No...

  13. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, Erkan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Ocsoy, Ismail [Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri 38039 (Turkey); Nanotechnology Research Center (ERNAM), Erciyes University, Kayseri 38039 (Turkey); Ozdemir, Nalan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Soylak, Mustafa, E-mail: soylak@erciyes.edu.tr [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey)

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L{sup −1} and 8.8 μg L{sup −1}, respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. - Highlights: • The synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers is reported. • The nanoflowers were utilized for solid phase microextraction of

  14. Absorptive products

    International Nuclear Information System (INIS)

    Assarsson, P.G.; King, P.A.

    1976-01-01

    Applications for hydrophile gels produced by the radiation induced cross-linking in aqueous solution of polyethylene oxide and starch, as described in Norwegian patent 133501 (INIS RN 281494), such as sanitary napkins (diapers) and sanitary towels, are discussed. The process itself is also discussed and results, expressed as the percentage of insoluble gel and its absorptive capacity for saline solution as functions of the ratio of polyethylene oxide to starch and the radiation dose, are presented. (JIW)

  15. Lead poisoning: The invisible disease

    Science.gov (United States)

    Friend, Milton

    1989-01-01

    Lead poisoning is an intoxication resulting from absorption of hazardous levels of lead into body tissues. Lead pellets from shot shells, when ingested, are the most common source of lead poisoning in migratory birds. Other far less common sources include lead fishing sinkers, mine wastes, paint pigments, bullets, and other lead objects that are swallowed.

  16. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on the substantiation of health claims related to lactose and increase in calcium absorption leading to an increase in calcium retention (ID 668) pursuant to Article 13(1) of Regulation (EC) No 1924/2006

    DEFF Research Database (Denmark)

    Tetens, Inge

    claims in relation to lactose and increase in calcium absorption leading to an increase in calcium retention. The scientific substantiation is based on the information provided by the Member States in the consolidated list of Article 13 health claims and references that EFSA has received from Member...... States or directly from stakeholders. The food constituent that is the subject of the health claim is lactose. The Panel considers that lactose is sufficiently characterised. The claimed effect is “calcium absorption”. The target population is assumed to be the general population. The Panel notes...... between the consumption of lactose and an increase in calcium absorption leading to an increase in calcium retention....

  17. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples.

    Science.gov (United States)

    Yilmaz, Erkan; Ocsoy, Ismail; Ozdemir, Nalan; Soylak, Mustafa

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L(-)(1) and 8.8 μg L(-)(1), respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Linear absorptive dielectrics

    Science.gov (United States)

    Tip, A.

    1998-06-01

    Starting from Maxwell's equations for a linear, nonconducting, absorptive, and dispersive medium, characterized by the constitutive equations D(x,t)=ɛ1(x)E(x,t)+∫t-∞dsχ(x,t-s)E(x,s) and H(x,t)=B(x,t), a unitary time evolution and canonical formalism is obtained. Given the complex, coordinate, and frequency-dependent, electric permeability ɛ(x,ω), no further assumptions are made. The procedure leads to a proper definition of band gaps in the periodic case and a new continuity equation for energy flow. An S-matrix formalism for scattering from lossy objects is presented in full detail. A quantized version of the formalism is derived and applied to the generation of Čerenkov and transition radiation as well as atomic decay. The last case suggests a useful generalization of the density of states to the absorptive situation.

  19. Multifunctional hybrids for electromagnetic absorption

    International Nuclear Information System (INIS)

    Huynen, I.; Quievy, N.; Bailly, C.; Bollen, P.; Detrembleur, C.; Eggermont, S.; Molenberg, I.; Thomassin, J.M.; Urbanczyk, L.

    2011-01-01

    Highlights: → EM absorption requires low dielectric constant and ∼1 S/m electrical conductivity. → New hybrids were processed with CNT-filled polymer foam inserted in Al honeycomb. → The EM absorption in the GHz range is superior to any known material. → A closed form model is used to guide the design of the hybrid. → The architectured material is light with potential for thermal management. - Abstract: Electromagnetic (EM) interferences are ubiquitous in modern technologies and impact on the reliability of electronic devices and on living cells. Shielding by EM absorption, which is preferable over reflection in certain instances, requires combining a low dielectric constant with high electrical conductivity, which are antagonist properties in the world of materials. A novel class of hybrid materials for EM absorption in the gigahertz range has been developed based on a hierarchical architecture involving a metallic honeycomb filled with a carbon nanotube-reinforced polymer foam. The waveguide characteristics of the honeycomb combined with the performance of the foam lead to unexpectedly large EM power absorption over a wide frequency range, superior to any known material. The peak absorption frequency can be tuned by varying the shape of the honeycomb unit cell. A closed form model of the EM reflection and absorption provides a tool for the optimization of the hybrid. This designed material sets the stage for a new class of sandwich panels combining high EM absorption with mass efficiency, stiffness and thermal management.

  20. Application of Zeeman graphite furnace atomic absorption spectrometry with high-frequency modulation polarization for the direct determination of aluminum, beryllium, cadmium, chromium, mercury, manganese, nickel, lead, and thallium in human blood.

    Science.gov (United States)

    Ivanenko, Natalya B; Solovyev, Nikolay D; Ivanenko, Anatoly A; Ganeev, Alexander A

    2012-10-01

    Determination of aluminum (Al), beryllium (Be), cadmium (Cd), chromium (Cr), mercury (Hg), manganese (Mn), nickel (Ni), lead (Pb), and thallium (Tl) concentrations in human blood using high-frequency modulation polarization Zeeman graphite furnace atomic absorption spectrometry (GFAAS) was performed. No sample digestion was used in the current study. Blood samples were diluted with deionized water or 0.1 % (m/v) Triton X-100 solution for Tl. Dilution factors ranged from 1/5 per volume for Be and Tl to 1/20 per volume for Cd and Pb. For Tl, Cd, and Hg, noble metals (gold, platinum, rhodium, etc.) were applied as surface modifiers. To mitigate chloride interference, 2 % (m/v) solution of NH(4)NO(3) was used as matrix modifier for Tl and Ni assessment. The use of Pd(NO(3))(2) as oxidative modifier was necessary for blood Hg and Tl measurement. Validation of the methods was performed by analyzing two-level reference material Seronorm. The precision of the designed methods as relative SD was between 4 and 12 % (middle of a dynamic range) depending on the element. For additional validation, spiked blood samples were analyzed. Limits of detection (LoDs, 3σ, n = 10) for undiluted blood samples were 2.0 μg L(-1) for Al, 0.08 μg L(-1) for Be, 0.10 μg L(-1) for Cd, 2.2 μg L(-1) for Cr, 7 μg L(-1) for Hg, 0.4 μg L(-1) for Mn, 2.3 μg L(-1) for Ni, 3.4 μg L(-1) for Pb, and 0.5 μg L(-1) for Tl. The LoDs achieved allowed determination of Al, Cd, Cr, Mn, Ni, and Pb at both toxic and background levels. Be, Hg, and Tl could be reliably measured at toxic levels only. The methods developed are used for clinical diagnostics and biological monitoring of work-related exposure.

  1. Multiple efflux pumps are involved in the transepithelial transport of colchicine: combined effect of p-glycoprotein and multidrug resistance-associated protein 2 leads to decreased intestinal absorption throughout the entire small intestine.

    Science.gov (United States)

    Dahan, Arik; Sabit, Hairat; Amidon, Gordon L

    2009-10-01

    The purpose of this study was to thoroughly characterize the efflux transporters involved in the intestinal permeability of the oral microtubule polymerization inhibitor colchicine and to evaluate the role of these transporters in limiting its oral absorption. The effects of P-glycoprotein (P-gp), multidrug resistance-associated protein 2 (MRP2), and breast cancer resistance protein (BCRP) inhibitors on colchicine bidirectional permeability were studied across Caco-2 cell monolayers, inhibiting one versus multiple transporters simultaneously. Colchicine permeability was then investigated in different regions of the rat small intestine by in situ single-pass perfusion. Correlation with the P-gp/MRP2 expression level throughout different intestinal segments was investigated by immunoblotting. P-gp inhibitors [N-(4-[2-(1,2,3,4-tetrahydro-6,7-dimethoxy-2-isoquinolinyl)ethyl]-phenyl)-9,10-dihydro-5-methoxy-9-oxo-4-acridine carboxamide (GF120918), verapamil, and quinidine], and MRP2 inhibitors [3-[[3-[2-(7-chloroquinolin-2-yl)vinyl]phenyl]-(2-dimethylcarbamoylethylsulfanyl)methylsulfanyl] propionic acid (MK571), indomethacin, and p-aminohippuric acid (p-AH)] significantly increased apical (AP)-basolateral (BL) and decreased BL-AP Caco-2 transport in a concentration-dependent manner. No effect was obtained by the BCRP inhibitors fumitremorgin C (FTC) and pantoprazole. P-gp/MRP2 inhibitors combinations greatly reduced colchicine mucosal secretion, including complete abolishment of efflux (GF120918/MK571). Colchicine displayed low (versus metoprolol) and constant permeability along the rat small-intestine. GF120918 significantly increased colchicine permeability in the ileum with no effect in the jejunum, whereas MK571 augmented jejunal permeability without changing the ileal transport. The GF120918/MK571 combination caused an effect similar to that of MK571 alone in the jejunum and to that of GF120918 alone in the ileum. P-gp expression followed a gradient increasing from

  2. Absorção e distribuição de chumbo em plantas devetiver, jureminha e algaroba Absorption and distribution of lead in vetiver, mimosa and mesquite plants

    Directory of Open Access Journals (Sweden)

    Jailson do Carmo Alves

    2008-06-01

    , and studies concerning heavy metal tolerance, absorption and distribution in plants are essential for the success of such programs. This study was carried out to evaluate the tolerance, absorption and distribution of lead (Pb in vetiver grass [Vetiveria zizanioides (L. Nash], mimosa [Desmanthus virgatus (L. Willd] and mesquite trees [Prosopis juliflora (SW DC] subjected to increasing lead doses in solution. The experiment was conducted under a screenhouse, at the DSER/CCA/UFPB, Areia-PB, Brazil. The species were grown in nutrient solution containing increasing Pb levels (0, 50, 100 and 200 mg L-1 during a 45-day exposure period. An entirely randomized split-plot design was used with three replicates. The main plot was represented by the plant species and the subplot by Pb levels. The increased Pb levels caused significant reductions of dry mass of the root, shoot and whole plant (root + shoot in the three species under study. Based on critical toxicity levels, the tolerance of vetiver to Pb contamination was higher than in the other species. In vetiver and mesquite plants, the roots were the component most sensitive to Pb contamination, whereas a similar response to Pb by all plant components was observed for mimosa. Total Pb concentrations and content in plant compartments were significantly affected by the increasing Pb levels in solution, and a higher accumulation of this element was observed in the roots of the three species under study. The highest Pb concentration and content were found in all compartments of vetiver, which suggests a high potential of this grass for phytoremediation of Pb-contaminated areas.

  3. LEADING WITH LEADING INDICATORS

    International Nuclear Information System (INIS)

    PREVETTE, S.S.

    2005-01-01

    This paper documents Fluor Hanford's use of Leading Indicators, management leadership, and statistical methodology in order to improve safe performance of work. By applying these methods, Fluor Hanford achieved a significant reduction in injury rates in 2003 and 2004, and the improvement continues today. The integration of data, leadership, and teamwork pays off with improved safety performance and credibility with the customer. The use of Statistical Process Control, Pareto Charts, and Systems Thinking and their effect on management decisions and employee involvement are discussed. Included are practical examples of choosing leading indicators. A statistically based color coded dashboard presentation system methodology is provided. These tools, management theories and methods, coupled with involved leadership and employee efforts, directly led to significant improvements in worker safety and health, and environmental protection and restoration at one of the nation's largest nuclear cleanup sites

  4. Emission and absorption of radiation

    International Nuclear Information System (INIS)

    Fetter, S.

    1992-01-01

    A full understanding of fissile-material detection requires a solid knowledge of nuclear physics, especially the emission and absorption of radiation. The purpose of this paper is therefore to give a brief explanation of these processes so that the reader can better understand the assumptions leading to the results in the main text

  5. Use of a novel docosahexaenoic acid (DHA) formulation versus control in a neonatal porcine model of short bowel syndrome leads to greater intestinal absorption and higher systemic levels of DHA

    Science.gov (United States)

    Martin, Camilia R.; Stoll, Barbara; Cluette-Brown, Joanne; Akinkuotu, Adesola C.; Olutoye, Oluyinka O.; Gura, Kathleen M.; Singh, Pratibha; Zaman, Munir M.; Perillo, Michael C.; Puder, Mark; Freedman, Steven D.; Burrin, Doug

    2017-01-01

    Infants with short bowel syndrome (SBS) are at high risk for malabsorption, malnutrition, and failure to thrive. The objective of this study was to evaluate in a porcine model of SBS, the systemic absorption of a novel enteral Docosahexaenoic acid (DHA) formulation that forms micelles independent of bile salts (DHA-ALT®). We hypothesized that enteral delivery of DHA-ALT® would result in higher blood levels of DHA compared to a control DHA preparation due to improved intestinal absorption. SBS was induced in term piglets through a 75% mid-jejunoileal resection and the piglets randomized to either DHA-ALT® or control DHA formulation (N=5 per group) for 4 postoperative days. The median ± IQR difference in final versus starting weight was 696 ± 425g in the DHA-ALT® group compared to 132 ± 278g in the controls (p=.08). Within 12 hours, median ± IQR DHA and eicosapentaenoic acid plasma levels (mol%) were significantly higher in the DHA-ALT® vs. control group (4.1 ± 0.3 vs 2.5 ± 0.5, p=0.009; 0.7 ± 0.3 vs 0.2 ± 0.005, p=0.009, respectively). There were lower fecal losses of DHA and greater ileal tissue incorporation with DHA-ALT® versus the control. Morphometric analyses demonstrated an increase in proximal jejunum and distal ileum villus height in the DHA-ALT® group compared to controls (p=0.01). In a neonatal porcine model of SBS, enteral administration of a novel DHA preparation that forms micelles independent of bile salts resulted in increased fatty acid absorption, increased ileal tissue incorporation, and increased systemic levels of DHA. PMID:28385289

  6. Use of a novel docosahexaenoic acid formulation vs control in a neonatal porcine model of short bowel syndrome leads to greater intestinal absorption and higher systemic levels of DHA.

    Science.gov (United States)

    Martin, Camilia R; Stoll, Barbara; Cluette-Brown, Joanne; Akinkuotu, Adesola C; Olutoye, Oluyinka O; Gura, Kathleen M; Singh, Pratibha; Zaman, Munir M; Perillo, Michael C; Puder, Mark; Freedman, Steven D; Burrin, Doug

    2017-03-01

    Infants with short bowel syndrome (SBS) are at high risk for malabsorption, malnutrition, and failure to thrive. The objective of this study was to evaluate in a porcine model of SBS, the systemic absorption of a novel enteral Docosahexaenoic acid (DHA) formulation that forms micelles independent of bile salts (DHA-ALT®). We hypothesized that enteral delivery of DHA-ALT® would result in higher blood levels of DHA compared to a control DHA preparation due to improved intestinal absorption. SBS was induced in term piglets through a 75% mid-jejunoileal resection and the piglets randomized to either DHA-ALT® or control DHA formulation (N=5 per group) for 4 postoperative days. The median±IQR difference in final vs starting weight was 696±425 g in the DHA-ALT® group compared to 132±278 g in the controls (P=.08). Within 12 hours, median±IQR DHA and eicosapentaenoic acid plasma levels (mol%) were significantly higher in the DHA-ALT® vs control group (4.1±0.3 vs 2.5±0.5, P=.009; 0.7±0.3 vs 0.2±0.005, P=.009, respectively). There were lower fecal losses of DHA and greater ileal tissue incorporation with DHA-ALT® vs the control. Morphometric analyses demonstrated an increase in proximal jejunum and distal ileum villus height in the DHA-ALT® group compared to controls (P=.01). In a neonatal porcine model of SBS, enteral administration of a novel DHA preparation that forms micelles independent of bile salts resulted in increased fatty acid absorption, increased ileal tissue incorporation, and increased systemic levels of DHA. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Electrothermal atomisation atomic absorption conditions and matrix modifications for determining antimony, arsenic, bismuth, cadmium, gallium, gold, indium, lead, molybdenum, palladium, platinum, selenium, silver, tellurium, thallium and tin following back-extraction of organic aminohalide extracts

    Science.gov (United States)

    Clark, J.R.

    1986-01-01

    A multi-element organic-extraction and back-extraction procedure, that had been developed previously to eliminate matrix interferences in the determination of a large number of trace elements in complex materials such as geological samples, produced organic and aqueous solutions that were complex. Electrothermal atomisation atomic absorption conditions and matrix modifications have been developed for 13 of the extracted elements (Ag, As, Au, Bi, Cd, Ga, In, Pb, Sb, Se, Sn, Te and Tl) that enhance sensitivity, alleviate problems resulting from the complex solutions and produce acceptable precision. Platinum, Pd and Mo can be determined without matrix modification directly on the original unstripped extracts.

  8. Radioactive lead studies in the human

    International Nuclear Information System (INIS)

    Blake, K.C.H.

    1980-08-01

    The differing susceptibility of individuals to the toxic effects of chronic lead exposure has never been fully understood. As the major intake of lead in the human is from food and beverages, any variation between individuals of the quantity of lead absorbed from the gut, and of the distribution and excretion of this lead, may account for the differences in individual susceptibility. The food and beverages themselves may have an influence, and to investigate their effects on absorption, distribution and excretion of lead, experiments were performed on normal subjects using a short lived radionuclide of lead, 203 Pb, and instruments generally available in Nuclear Medicine. Lead absorption between different individuals showed a wide variation when 203 Pb was taken as a single dose between meals. Minerals were found to be mainly responsible for affecting absorption when one subject ingested 203 Pb in control meals from which one dietary constituent at a time was omitted. Calcium and phosphorous were found to reduce the absorption of 203 Pb to approximately the same level as that produced by the total minerals. Calcium reduced absorption more than phosphorous when these minerals were ingested separately with 203 Pb. It was concluded that the calcium and phosphorous in the diet could influence susceptibility to lead toxicity through changes in the absorption of food and water lead and in the distribution of lead in the body. The results suggest that the prophylactic effect of calcium on lead absorption should be recognised and applied in this time of increased environmental levels of lead

  9. Absorption and Metabolism of Xanthophylls

    Directory of Open Access Journals (Sweden)

    Eiichi Kotake-Nara

    2011-06-01

    Full Text Available Dietary carotenoids, especially xanthophylls, have attracted significant attention because of their characteristic biological activities, including anti-allergic, anti-cancer, and anti-obese actions. Although no less than forty carotenoids are ingested under usual dietary habits, only six carotenoids and their metabolites have been found in human tissues, suggesting selectivity in the intestinal absorption of carotenoids. Recently, facilitated diffusion in addition to simple diffusion has been reported to mediate the intestinal absorption of carotenoids in mammals. The selective absorption of carotenoids may be caused by uptake to the intestinal epithelia by the facilitated diffusion and an unknown excretion to intestinal lumen. It is well known that β-carotene can be metabolized to vitamin A after intestinal absorption of carotenoids, but little is known about the metabolic transformation of non provitamin A xanthophylls. The enzymatic oxidation of the secondary hydroxyl group leading to keto-carotenoids would occur as a common pathway of xanthophyll metabolism in mammals. This paper reviews the absorption and metabolism of xanthophylls by introducing recent advances in this field.

  10. Absorption and metabolism of xanthophylls.

    Science.gov (United States)

    Kotake-Nara, Eiichi; Nagao, Akihiko

    2011-01-01

    Dietary carotenoids, especially xanthophylls, have attracted significant attention because of their characteristic biological activities, including anti-allergic, anti-cancer, and anti-obese actions. Although no less than forty carotenoids are ingested under usual dietary habits, only six carotenoids and their metabolites have been found in human tissues, suggesting selectivity in the intestinal absorption of carotenoids. Recently, facilitated diffusion in addition to simple diffusion has been reported to mediate the intestinal absorption of carotenoids in mammals. The selective absorption of carotenoids may be caused by uptake to the intestinal epithelia by the facilitated diffusion and an unknown excretion to intestinal lumen. It is well known that β-carotene can be metabolized to vitamin A after intestinal absorption of carotenoids, but little is known about the metabolic transformation of non provitamin A xanthophylls. The enzymatic oxidation of the secondary hydroxyl group leading to keto-carotenoids would occur as a common pathway of xanthophyll metabolism in mammals. This paper reviews the absorption and metabolism of xanthophylls by introducing recent advances in this field.

  11. Survey of content of cadmium, calcium, chromium, copper, iron, lead, magnesium, manganese, mercury, sodium and zinc in chamomile and green tea leaves by electrothermal or flame atomizer atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Prkić Ante

    2018-03-01

    Full Text Available Due to the simplicity of tea preparation (pouring hot water onto different dried herbs and its high popularity as a beverage, monitoring and developing a screening methodology for detecting the metal content is very important. The concentrations of Cd, Ca, Cr, Cu, Fe, Pb, Mg, Mn, Hg, Na and Zn in 8 samples of green tea (Camellia sinesis and in 11 samples chamomile (Matricaria chamomilla L. purchased both at local herbal pharmacies and supermarkets were determined using electrothermal atomizer atomic absorption spectrometry (ETAAS and flame atomizer atomic absorption spectrometry (FAAS. The found concentrations in chamomile were: Cd (0.008 – 284 mg kg−1, Ca (2.42 – 6.29%, Cr (0.91 – 6.92 mg kg−1, Cu (6.27 – 11.39 mg kg−1, Fe (133.5 – 534 mg kg−1, Pb (0.561 – 1.277 mg kg−1, Mg (2.27 – 3.73%, Mn (62.2 – 165.6 mg kg−1, Hg (0.660 – 1.346 μg kg−1, Na (0.91 – 1.28% and Zn (63.37 – 108.5 mg kg−1, in green tea Cd (36.29 – 202.1 mg kg−1, Ca (2.77 – 6.40%, Cr (1.520 – 5.278 mg kg−1, Cu (9.354 – 22.56 mg kg−1, Fe (162.6 – 513.3 mg kg−1, Pb (1.808 – 4.770 mg kg−1, Mg (1.41 – 2.62 %, Mn (1.147 – 1.729 g kg−1, Hg (1.045 – 2.802 μg kg−1, Na (0.44 – 0.98% and Zn (30.65 – 115.6 mg kg−1, respectively. Principal Component Analysis (PCA was applied to identify factors (soil, climate and country of origin influencing the content of the measured elements in herbal samples. The proposed methodology developed in this work was successfully applied to the detection of metals in herbal samples. The analysis showed that the content of toxic metals in green tea samples was significantly higher and very close to the maximum dose recommended by the World Health Organization (WHO.

  12. D-xylose absorption

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003606.htm D-xylose absorption To use the sharing features on this page, please enable JavaScript. D-xylose absorption is a laboratory test to determine ...

  13. Ultratrace determination of lead by hydride generation in-atomizer trapping atomic absorption spectrometry: Optimization of plumbane generation and analyte preconcentration in a quartz trap-and-atomizer device

    Energy Technology Data Exchange (ETDEWEB)

    Kratzer, Jan, E-mail: jkratzer@biomed.cas.cz

    2012-05-15

    A compact trap-and-atomizer device and a preconcentration procedure based on hydride trapping in excess of oxygen over hydrogen in the collection step, both constructed and developed previously in our laboratory, were employed to optimize plumbane trapping in this device and to develop a routine method for ultratrace lead determination subsequently. The inherent advantage of this preconcentration approach is that 100% preconcentration efficiency for lead is reached in this device which has never been reported before using quartz or metal traps. Plumbane is completely retained in the trap-and-atomizer device at 290 Degree-Sign C in oxygen-rich atmosphere and trapped species are subsequently volatilized at 830 Degree-Sign C in hydrogen-rich atmosphere. Effect of relevant experimental parameters on plumbane trapping and lead volatilization are discussed, and possible trapping mechanisms are hypothesized. Plumbane trapping in the trap-and-atomizer device can be routinely used for lead determination at ultratrace levels reaching a detection limit of 0.21 ng ml{sup -1} Pb (30 s preconcentration, sample volume 2 ml). Further improvement of the detection limit is feasible by reducing the blank signal and increasing the trapping time. - Highlights: Black-Right-Pointing-Pointer In-atomizer trapping HG-AAS was optimized for Pb. Black-Right-Pointing-Pointer A compact quartz trap-and-atomizer device was employed. Black-Right-Pointing-Pointer Generation, preconcentration and atomization steps were investigated in detail. Black-Right-Pointing-Pointer 100% preconcentration efficiency for lead was reached. Black-Right-Pointing-Pointer Routine analytical method was developed for Pb determination (LOD of 0.2 ng ml{sup -1} Pb).

  14. Ligandless surfactant mediated solid phase extraction combined with Fe₃O₄ nano-particle for the preconcentration and determination of cadmium and lead in water and soil samples followed by flame atomic absorption spectrometry: multivariate strategy.

    Science.gov (United States)

    Jalbani, N; Soylak, M

    2014-04-01

    In the present study, a microextraction technique combining Fe3O4 nano-particle with surfactant mediated solid phase extraction ((SM-SPE)) was successfully developed for the preconcentration/separation of Cd(II) and Pb(II) in water and soil samples. The analytes were determined by flame atomic absorption spectrometry (FAAS). The effective variables such as the amount of adsorbent (NPs), the pH, concentration of non-ionic (TX-114) and centrifugation time (min) were investigated by Plackett-Burman (PBD) design. The important variables were further optimized by central composite design (CCD). Under the optimized conditions, the detection limits (LODs) of Cd(II) and Pb(II) were 0.15 and 0.74 µg/L, respectively. The validation of the proposed procedure was checked by the analysis of certified reference materials of TMDA 53.3 fortified water and GBW07425 soil. The method was successfully applied for the determination of Cd(II) and Pb(II) in water and soil samples. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Lead poisoning

    Science.gov (United States)

    ... drinking water in homes containing pipes that were connected with lead solder . Although new building codes require ... lead in their bodies when they put lead objects in their mouths, especially if they swallow those ...

  16. Lead Poisoning

    Science.gov (United States)

    Lead is a metal that occurs naturally in the earth's crust. Lead can be found in all parts of our ... from human activities such as mining and manufacturing. Lead used to be in paint; older houses may ...

  17. Absorption and excretion tests

    International Nuclear Information System (INIS)

    Berberich, R.

    1988-01-01

    The absorption and excretion of radiopharmaceuticals is still of interest in diagnostic investigations of nuclear medicine. In this paper the most common methods of measuring absorption and excretion are described. The performance of the different tests and their standard values are discussed. More over the basic possibilities of measuring absorption and excretion including the needed measurement equipments are presented. (orig.) [de

  18. Separation and preconcentration of lead(II), cobalt(II), and nickel(II) on EDTA immobilized activated carbon cloth prior to flame atomic absorption spectrometric determination in environmental samples

    OpenAIRE

    ALOTHMAN, ZEID ABDULLAH; YILMAZ, ERKAN; HABİLA, MOHAMED; SOYLAK, MUSTAFA

    2015-01-01

    The synthesis and characterization of ethylenediaminetetraacetic acid immobilized activated carbon cloth was performed in the present work. It was used for preconcentration-separation of lead(II), cobalt(II), and nickel(II) at trace levels as an adsorbent. Factors including pH, concentration and volume of eluent, sample and eluent flow rates, sample volume, and effect of coexisting ions on the solid phase extraction of analytes were examined. The preconcentration factor was 50. The detection ...

  19. Solid-Phase Extraction with Diethyldithiocarbamate as Chelating Agent for Preconcentration and Trace Determination of Copper, Iron and Lead in Fruit Wine and Distilled Spirit by Flame Atomic Absorption Spectrometry

    Directory of Open Access Journals (Sweden)

    Saksit Chanthal

    2011-01-01

    Full Text Available Some heavy metals that present in wine and distilled spirit as background contamination are generally found at trace level particularly less than detection limit of common analytical techniques including flame atomic absorption spectrometry (FAAS. Thus, preconcentration method of the trace metals was developed. The optimum conditions for diethyldithiocarbamate (DDTC complexes of Cu, Fe and Pb were then investigated for the preconcentration step using C18 solid-phase extraction prior to measurement by FAAS. The preconcentration factor of 15-fold was obtained with the appropriate ratio of sample volume used (150 mL to 10 mL final volume giving their method recoveries of Cu, Fe and Pb found in the ranges of 96.5-107, 102-116 and 91.7-107%, respectively. Precision determinations (n = 10 for 0.1 mg L-1 of Cu, Fe and Pb each in a model solution were 3.7, 4.2 and 7.1 %RSD respectively. The detection limits (3SD of Cu, Fe and Pb were found to be 1.4, 3.3 and 5.7 μg L-1, respectively. The developed method was applied to ten samples of local fruit wines and five samples of distilled spirits, resulting in the ranges of 0.012-0.80 and 0.12-8.8 mg L-1 for Cu; 0.18-3.4 and 0.036-0.29 mg L-1 for Fe and 0.0070-0.053 and 0.014-0.026 mg L-1 for Pb, respectively. Therefore, the method is simple and inexpensive for routine analysis of the trace metals in these samples to overcome limit of detection of the instrument used.

  20. Calcium absorption and achlorhydria

    International Nuclear Information System (INIS)

    Recker, R.R.

    1985-01-01

    Defective absorption of calcium has been thought to exist in patients with achlorhydria. The author compared absorption of calcium in its carbonate form with that in a pH-adjusted citrate form in a group of 11 fasting patients with achlorhydria and in 9 fasting normal subjects. Fractional calcium absorption was measured by a modified double-isotope procedure with 0.25 g of calcium used as the carrier. Mean calcium absorption (+/- S.D.) in the patients with achlorhydria was 0.452 +/- 0.125 for citrate and 0.042 +/- 0.021 for carbonate (P less than 0.0001). Fractional calcium absorption in the normal subjects was 0.243 +/- 0.049 for citrate and 0.225 +/- 0.108 for carbonate (not significant). Absorption of calcium from carbonate in patients with achlorhydria was significantly lower than in the normal subjects and was lower than absorption from citrate in either group; absorption from citrate in those with achlorhydria was significantly higher than in the normal subjects, as well as higher than absorption from carbonate in either group. Administration of calcium carbonate as part of a normal breakfast resulted in completely normal absorption in the achlorhydric subjects. These results indicate that calcium absorption from carbonate is impaired in achlorhydria under fasting conditions. Since achlorhydria is common in older persons, calcium carbonate may not be the ideal dietary supplement

  1. Evaluation of V, Ir, Ru, V-Ir, V-Ru, and W-V as permanent chemical modifiers for the determination of cadmium, lead, and zinc in botanic and biological slurries by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Acar, Orhan

    2005-01-01

    Permanent modifiers (V, Ir, Ru, V-Ir, V-Ru, and W-V) thermally coated on to platforms of pyrolytic graphite tubes were employed for the determination of Cd, Pb, and Zn in botanic and biological slurries by electrothermal atomic absorption spectrometry (ETAAS). Conventional Pd + Mg(NO 3 ) 2 modifier mixture was also used for the determination of analytes in slurries and digested samples. Optimum masses and mass ratios of permanent modifiers for Cd, Pb, and Zn in slurry sample solutions were investigated. The 280 μg of V, 280 μg of V + 200 μg of Ir, 280 μg of V + 200 μg of Ru or 240 μg of W + 280 μg of V in 0.2% (v/v) Triton X-100 plus 0.5% (v/v) HNO 3 mixture was found as efficient as 5 μg of Pd + 3 μg of Mg(NO 3 ) 2 modifier mixture for obtaining thermal stabilization, and for obtaining best recoveries. Optimization conditions of analytes, such as pyrolysis and atomization temperature, characteristic masses and detection limits, and atomization and background peak profiles were studied with permanent and 5 μg of Pd + 3 μg of Mg(NO 3 ) 2 conventional modifiers and compared with each other. The permanent V-Ir, V-Ru, and W-V modifiers remained stable for approximately 250-300 firings when 20 μl of slurries and digested samples were delivered into the atomizer. In addition, the mixed permanent modifiers increase the tube lifetime by 50-95% when compared with untreated platforms. The characteristic masses and detection limits of analytes (dilution factor of 125 ml g -1 ) obtained with V-Ir based on integrated absorbance as example for 0.8% (m/v) slurries were 1.0 pg and 3 ng g -1 for Cd, 18 pg and 17 ng g -1 for Pb, and 0.7 pg and 4 ng g -1 for Zn, respectively. The results of analytes obtained by employing V-Ir, V-Ru, and W-V permanent modifier mixtures in botanic and biological certified and standard reference materials were in agreement with the certified values of reference materials

  2. Aerosol Absorption Measurements in MILAGRO.

    Science.gov (United States)

    Gaffney, J. S.; Marley, N. A.; Arnott, W. P.; Paredes-Miranda, L.; Barnard, J. C.

    2007-12-01

    During the month of March 2006, a number of instruments were used to determine the absorption characteristics of aerosols found in the Mexico City Megacity and nearby Valley of Mexico. These measurements were taken as part of the Department of Energy's Megacity Aerosol Experiment - Mexico City (MAX-Mex) that was carried out in collaboration with the Megacity Interactions: Local and Global Research Observations (MILAGRO) campaign. MILAGRO was a joint effort between the DOE, NSF, NASA, and Mexican agencies aimed at understanding the impacts of a megacity on the urban and regional scale. A super-site was operated at the Instituto Mexicano de Petroleo in Mexico City (designated T-0) and at the Universidad Technologica de Tecamac (designated T-1) that was located about 35 km to the north east of the T-0 site in the State of Mexico. A third site was located at a private rancho in the State of Hidalgo approximately another 35 km to the northeast (designated T-2). Aerosol absorption measurements were taken in real time using a number of instruments at the T-0 and T-1 sites. These included a seven wavelength aethalometer, a multi-angle absorption photometer (MAAP), and a photo-acoustic spectrometer. Aerosol absorption was also derived from spectral radiometers including a multi-filter rotating band spectral radiometer (MFRSR). The results clearly indicate that there is significant aerosol absorption by the aerosols in the Mexico City megacity region. The absorption can lead to single scattering albedo reduction leading to values below 0.5 under some circumstances. The absorption is also found to deviate from that expected for a "well-behaved" soot anticipated from diesel engine emissions, i.e. from a simple 1/lambda wavelength dependence for absorption. Indeed, enhanced absorption is seen in the region of 300-450 nm in many cases, particularly in the afternoon periods indicating that secondary organic aerosols are contributing to the aerosol absorption. This is likely due

  3. Experimental lead poisoning in chickens

    Energy Technology Data Exchange (ETDEWEB)

    Silven, L.

    1967-01-01

    Poisoning of water fowl due to the intake of lead shot is not rare in the USA. In order to study this kind of poisoning more closely domestic fowl were given varying amounts of lead shot and lead powder. This treatment did not provoke any symptoms of poisoning. Chemical analyses of different organs, muscles, skeleton and eggs yielded low lead values. It is concluded that the low toxicity of lead administered as lead shot to the domestic fowl is due to a low absorption rate from the gastro-intestinal tract.

  4. Low to moderate alcohol intake is not associated with increased mortality after breast cancer.

    Science.gov (United States)

    Flatt, Shirley W; Thomson, Cynthia A; Gold, Ellen B; Natarajan, Loki; Rock, Cheryl L; Al-Delaimy, Wael K; Patterson, Ruth E; Saquib, Nazmus; Caan, Bette J; Pierce, John P

    2010-03-01

    Both alcohol consumption and obesity have been linked with breast cancer morbidity and mortality. An inverse association between alcohol intake and obesity suggests possible confounding between these variables (and perhaps other factors) with breast cancer outcomes. Alcohol intake (beer, wine, spirits, and total) was examined in 3,088 women previously diagnosed and treated for breast cancer within an intervention trial that targeted vegetables, fiber, and fat but not alcohol or weight loss. Factors associated with baseline alcohol intake were included in Cox proportional hazards models for recurrence and mortality. Alcohol intake was significantly associated with higher education and physical activity levels. Neither light alcohol intake nor obesity was significantly associated with breast cancer recurrence, but moderate alcohol intake >300 g/mo was protective against all-cause mortality (hazard ratio, 0.69; 95% confidence intervals, 0.49-0.97) in a proportional hazards model adjusted for obesity. Obese women were 61% more likely to be nondrinkers than drinkers, and 76% more likely to be light drinkers than moderate/heavy drinkers. In nonobese women, alcohol intake >10 g/mo was associated with lower risk of all-cause mortality (hazard ratio, 0.68; 95% confidence intervals, 0.51-0.91). Light alcohol intake, regardless of body weight, did not increase the risk of breast cancer recurrence or all-cause mortality in this cohort of middle-aged women previously diagnosed with breast cancer. Alcohol intake was associated with other favorable prognostic indicators, which may explain its apparent protective effect in nonobese women.

  5. Opsite Plus in the managment of low to moderate exuding wounds.

    Science.gov (United States)

    Fear, M

    This article discusses the use of OpSite Plus (formerly known as OpSite Post-Op) in the community setting. This semipermeable film dressing with an absorbent pad was evaluated by the community hospital and by practice and district nurses within Plymouth's NHS Primary Care Trust.

  6. Reynolds number effects in a turbulent pipe flow for low to moderate Re

    NARCIS (Netherlands)

    Toonder, den J.M.J.; Nieuwstadt, F.T.M.

    1997-01-01

    We present in this paper high resolution, two-dimensional LDV measurements in a turbulent pipe flow of water over the Reynolds number range 500025000. Results for the turbulence statistics up to the fourth moment are presented, as well as power spectra in the near-wall region. These results clearly

  7. Wavefront-guided versus standard laser in situ keratomileusis to correct low to moderate myopia.

    NARCIS (Netherlands)

    Nuijts, R.M.; Nabar, V.A.; Hament, W.J.; Eggink, F.A.G.J.

    2002-01-01

    To evaluate the 6-month refractive outcomes of wavefront-guided laser in situ keratomileusis (LASIK) (Zyoptix, Bausch & Lomb) versus standard LASIK (PlanoScan, Bausch & Lomb).Department of Ophthalmology, University Hospital Maastricht, Maastricht, The Netherlands.In a prospective randomized study,

  8. Low-to-moderate nitrogen and phosphorus concentrations accelerate microbially driven litter breakdown rates

    Science.gov (United States)

    John S. Kominoski; Amy D. Rosemond; Jonathan P. Benstead; Vladislav Gulis; John C. Maerz; David Manning

    2015-01-01

    Particulate organic matter (POM) processing is an important driver of aquatic ecosystem productivity that is sensitive to nutrient enrichment and drives ecosystem carbon (C) loss. Although studies of single concentrations of nitrogen (N) or phosphorus (P) have shown effects at relatively low concentrations, responses of litter breakdown rates along gradients of low-to-...

  9. Lower blasthole pressures: a means of reducing costs when blasting rocks of low to moderate strength

    Energy Technology Data Exchange (ETDEWEB)

    Hagan, T.N.; Gibson, I.M.

    1988-03-01

    From a purely mechanical viewpoint, each explosive charge should produce a peak blasthole pressure (P/sub b/) that just fails to crush (i.e. pulverise or plastically deform) the rock which surrounds it. Where P/sub b/ exceeds a critical value, some explosion energy is wasted in crushing an annular section of rock immediately around each charge. As a rock's dynamic compressive breaking strain decreases, so should P/sub b/ (Hagan, 1977b). This paper reviews information on, and anticipates the blasting performance of, bulk charges having effective densities which are as low as about 40% of that for ammonium nitrate fuel oil (ANFO). It also outlines the potential advantages of extending the reaction periods of charges, even to the extent that explosive reactions continue after the blasthole wall and stemming have started to move. The paper then proceeds to define situations in which the use of such lower-pressure charges is likely to result in greatest reductions in mining costs. Some methods of applying bulk charges having effective densities in the 0.3-0.8 g cm/sup -3/ range and/or lower reaction rates are suggested. 15 refs., 3 figs.

  10. Optimization of Brayton cycles for low-to-moderate grade thermal energy sources

    International Nuclear Information System (INIS)

    Rovira, Antonio; Muñoz-Antón, Javier; Montes, María José; Martínez-Val, José María

    2013-01-01

    Future electricity generation will involve low or moderate temperature technologies. In such a scenario, optimisation of thermodynamic cycles will be a key task. This work presents a systematic analysis to find the operating regime where Brayton cycles reach the highest efficiency, using real substances and given heat source and sink temperatures. Several configurations using fluids close to its critical point at the compressor inlet are considered. Irreversibility sources are carefully analysed, as well as the type of working fluid. The analysis is performed by means of a theoretical approach to obtain some trends, which are afterwards validated with real gases. Results show that the efficiency and the specific work improve if the compressor inlet is close to the critical point. Furthermore, these cycles are less sensitive to pressure drops and politropic efficiencies than those working with ideal gases. The above features are more evident when the ratio of heat source and heat sink temperatures is low. The selection of the gas becomes a fundamental issue in this quest. Critical temperature should be close to ambient temperature, low critical pressure is advisable and the R/c p factor measured at the ideal gas condition should be low to further enhance the efficiency. - Highlights: • Performance analysis of Brayton cycles with the compressor inlet close to the critical point. • Cycles are not very sensitive to pressure drops and isentropic efficiencies of the compressor. • Gas selection becomes important, regarding the critical pressure and temperature as well as the kind of fluid. • R/c p factor measured at the ideal gas condition should be as low as possible

  11. Effects of low to moderate acute doses of pramipexole on impulsivity and cognition in healthy volunteers.

    Science.gov (United States)

    Hamidovic, Ajna; Kang, Un Jung; de Wit, Harriet

    2008-02-01

    The neurotransmitter dopamine is integrally involved in the rewarding effects of drugs, and it has also been thought to mediate impulsive behaviors in animal models. Most of the studies of drug effects on impulsive behaviors in humans have involved drugs with complex actions on different transmitter systems and different receptor subtypes. The present study was designed to characterize the effect of single doses of pramipexole, a D2/D3 agonist, on measures of cognitive and impulsive behavior, as well as on mood in healthy volunteers. Healthy men and women (N = 10) received placebo and 2 doses of pramipexole, 0.25 and 0.50 mg, in a within-subject, double-blinded study. Outcome measures included changes in cognitive performance, assessed by the Automated Neuropsychological Assessment Metrics, several behavioral measures related to impulsive behavior, including the Balloon Analogue Risk Task, Delay Discounting Task, Go/No-Go Task, Card Perseveration Task, and subjective ratings of mood assessed by Addiction Research Center Inventory, Profile of Mood States, and Drug Effects Questionnaire. Pramipexole decreased positive ratings of mood (euphoria, intellectual efficiency, and energy) and increased both subjectively reported sedation and behavioral sedation indicated by impaired cognitive performance on several measures of the Automated Neuropsychological Assessment Metrics. Single low to medium doses of this drug did not produce a decrease in impulsive responding on behavioral measures included in this study. The sedative-like effects observed in this study may reflect presynaptic actions of the drug. Higher doses with postsynaptic actions may be needed to produce either behavioral or subjective stimulant-like effects.

  12. Orthokeratologic Lens Applications in the Correction of Low to Moderate Myopia

    Directory of Open Access Journals (Sweden)

    Emine Kalkan Akçay

    2013-12-01

    Full Text Available Purpose: To evaluate the efficacy and safety of orthokeratology in patients with low and medium myopia. Material and Method: Twenty six eyes of 6 male and 7 female patients were evaluated prospectively. The mean spherical equivalent was -3.87±1.35 D (-7 - -2.25 in 26 eyes. Individual semi-rigid, gas-permeable night Gelflex lenses (Australia were performed based on keratometry values, ambient pupil, mesopic pupil, and autorefractometry values providing best-corrected visual acuity (BCVA. In all cases, uncorrected and best-corrected visual acuity, refraction, keratometry, corneal topography, slit lamp and intraocular pressure measurements were evaluated on first day, at first week, and at first, third and sixth months. Results: While the mean uncorrected visual acuity (UCVA before orthokeratology (Ortho-K was 1.08±0.24 (0.4-1.3 logMAR, first week after Ortho-K, it was 0.24±0.27 (0-1 logMAR. The BCVA was 0.01±0.07 (0-0.4 logMAR prior and first week after Ortho-K. First week after Ortho-K, it was 0.22 logMAR at right and 1 logMAR at left. While the average UCVA of our cases at first month was 0.11±0.19 (0-0.8 logMAR, the average BCVA at first month was 0.018±0.08 (0-0.4 logMAR. No ophthalmological complications were noted. Discussion: Ortho-K is a safe and effective method for correction of low and moderate myopia in patients who do not prefer surgery and do not wish to wear glasses or contact lenses during the day. (Turk J Ophthalmol 2013; 43: 317-20

  13. Lead Toxicity

    Science.gov (United States)

    ... o Do not use glazed ceramics, home remedies, cosmetics, or leaded-crystal glassware unless you know that they are lead safe. o If you live near an industry, mine, or waste site that may have contaminated ...

  14. Absorption heat pumps

    International Nuclear Information System (INIS)

    Formigoni, C.

    1998-01-01

    A brief description of the difference between a compression and an absorption heat pump is made, and the reasons why absorption systems have spread lately are given. Studies and projects recently started in the field of absorption heat pumps, as well as criteria usually followed in project development are described. An outline (performance targets, basic components) of a project on a water/air absorption heat pump, running on natural gas or LPG, is given. The project was developed by the Robur Group as an evolution of a water absorption refrigerator operating with a water/ammonia solution, which has been on the market for a long time and recently innovated. Finally, a list of the main energy and cost advantages deriving from the use of absorption heat pumps is made [it

  15. Relational Leading

    DEFF Research Database (Denmark)

    Larsen, Mette Vinther; Rasmussen, Jørgen Gulddahl

    2015-01-01

    This first chapter presents the exploratory and curious approach to leading as relational processes – an approach that pervades the entire book. We explore leading from a perspective that emphasises the unpredictable challenges and triviality of everyday life, which we consider an interesting......, relevant and realistic way to examine leading. The chapter brings up a number of concepts and contexts as formulated by researchers within the field, and in this way seeks to construct a first understanding of relational leading....

  16. Lead Test

    Science.gov (United States)

    ... to do renovation and repair projects using lead-safe work practices to avoid creating more lead dust or ... in a dangerous area? Yes. If you are working in a potentially harmful environment with exposure to lead dust or fumes: Wash ...

  17. Solar absorption surface panel

    Science.gov (United States)

    Santala, Teuvo J.

    1978-01-01

    A composite metal of aluminum and nickel is used to form an economical solar absorption surface for a collector plate wherein an intermetallic compound of the aluminum and nickel provides a surface morphology with high absorptance and relatively low infrared emittance along with good durability.

  18. Nutrition and magnesium absorption

    NARCIS (Netherlands)

    Brink, E.J.

    1992-01-01

    The influence of various nutrients present in dairy products and soybean-based products on absorption of magnesium has been investigated. The studies demonstrate that soybean protein versus casein lowers apparent magnesium absorption in rats through its phytate component. However, true

  19. Zeeman atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Loos-Vollebregt, M.T.C. de.

    1980-01-01

    A new method of background correction in atomic absorption spectroscopy has recently been introduced, based on the Zeeman splitting of spectral lines in a magnetic field. A theoretical analysis of the background correction capability observed in such instruments is presented. A Zeeman atomic absorption spectrometer utilizing a 50 Hz sine wave modulated magnetic field is described. (Auth.)

  20. Leading Democratically

    Science.gov (United States)

    Brookfield, Stephen

    2010-01-01

    Democracy is the most venerated of American ideas, the one for which wars are fought and people die. So most people would probably agree that leaders should be able to lead well in a democratic society. Yet, genuinely democratic leadership is a relative rarity. Leading democratically means viewing leadership as a function or process, rather than…

  1. Quasar Absorption Studies

    Science.gov (United States)

    Mushotzky, Richard (Technical Monitor); Elvis, Martin

    2004-01-01

    The aim of the proposal is to investigate the absorption properties of a sample of inter-mediate redshift quasars. The main goals of the project are: Measure the redshift and the column density of the X-ray absorbers; test the correlation between absorption and redshift suggested by ROSAT and ASCA data; constrain the absorber ionization status and metallicity; constrain the absorber dust content and composition through the comparison between the amount of X-ray absorption and optical dust extinction. Unanticipated low energy cut-offs where discovered in ROSAT spectra of quasars and confirmed by ASCA, BeppoSAX and Chandra. In most cases it was not possible to constrain adequately the redshift of the absorber from the X-ray data alone. Two possibilities remain open: a) absorption at the quasar redshift; and b) intervening absorption. The evidences in favour of intrinsic absorption are all indirect. Sensitive XMM observations can discriminate between these different scenarios. If the absorption is at the quasar redshift we can study whether the quasar environment evolves with the Cosmic time.

  2. Uranium absorption study pile

    International Nuclear Information System (INIS)

    Raievski, V.; Sautiez, B.

    1959-01-01

    The report describes a pile designed to measure the absorption of fuel slugs. The pile is of graphite and comprises a central section composed of uranium rods in a regular lattice. RaBe sources and BF 3 counters are situated on either side of the center. A given uranium charge is compared with a specimen charge of about 560 kg, and the difference in absorption between the two noted. The sensitivity of the equipment will detect absorption variations of about a few ppm boron (10 -6 boron per gr. of uranium) or better. (author) [fr

  3. Total photon absorption

    International Nuclear Information System (INIS)

    Carlos, P.

    1985-06-01

    The present discussion is limited to a presentation of the most recent total photonuclear absorption experiments performed with real photons at intermediate energy, and more precisely in the region of nucleon resonances. The main sources of real photons are briefly reviewed and the experimental procedures used for total photonuclear absorption cross section measurements. The main results obtained below 140 MeV photon energy as well as above 2 GeV are recalled. The experimental study of total photonuclear absorption in the nuclear resonance region (140 MeV< E<2 GeV) is still at its beginning and some results are presented

  4. Leading change.

    Science.gov (United States)

    2017-02-27

    In response to feedback from nursing, midwifery and other care staff who wanted to understand better how the Leading Change, Adding Value framework applies to them, NHS England has updated its webpage to include practice examples.

  5. Absorption heat pump system

    Science.gov (United States)

    Grossman, G.

    1982-06-16

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  6. Zeeman atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Hadeishi, T.; McLaughlin, R.

    1978-08-01

    The design and development of a Zeeman atomic absorption spectrometer for trace element analysis are described. An instruction manual is included which details the operation, adjustment, and maintenance. Specifications and circuit diagrams are given

  7. Electronic and optical properties of lead iodide

    DEFF Research Database (Denmark)

    Ahuja, R.; Arwin, H.; Ferreira da Silva, A.

    2002-01-01

    The electronic properties and the optical absorption of lead iodide (PbI2) have been investigated experimentally by means of optical absorption and spectroscopic ellipsometry, and theoretically by a full-potential linear muffin-tin-orbital method. PbI2 has been recognized as a very promising...

  8. Revisiting Absorptive Capacity

    DEFF Research Database (Denmark)

    de Araújo, Ana Luiza Lara; Ulhøi, John Parm; Lettl, Christopher

    Absorptive capacity has mostly been perceived as a 'passive' outcome of R&D investments. Recently, however, a growing interest into its 'proactive' potentials has emerged. This paper taps into this development and proposes a dynamic model for conceptualizing the determinants of the complementary...... learning processes of absorptive capacity, which comprise combinative and adaptive capabilities. Drawing on survey data (n=169), the study concludes that combinative capabilities primarily enhance transformative and exploratory learning processes, while adaptive capabilities strengthen all three learning...

  9. Comment on resonant absorption

    International Nuclear Information System (INIS)

    Hammerling, P.

    1977-01-01

    An average over angles of incidence of the usual resonant absorption function is presented. This form is appropriate under experimental conditions where the angles of incidence vary greatly and in an unknown manner. For comparison a lens-ellipsoidal mirror illumination system with a known longitudinal aberration is considered. In the latter example the angles of incidence are readily obtained and the resulting resonance absorption function evaluated. The associated fields are calculated in a similar fashion. (author)

  10. Optical absorption measurement system

    International Nuclear Information System (INIS)

    Draggoo, V.G.; Morton, R.G.; Sawicki, R.H.; Bissinger, H.D.

    1989-01-01

    This patent describes a non-intrusive method for measuring the temperature rise of optical elements under high laser power optical loading to determine the absorption coefficient. The method comprises irradiating the optical element with a high average power laser beam, viewing the optical element with an infrared camera to determine the temperature across the optical element and calculating the absorption of the optical element from the temperature

  11. Determination of high content of copper lead zinc silver in Geo-logical Samples by Flame Atomic Absorption Spectrometry%火焰原子吸收法测定地质样品中高含量的铜铅锌银

    Institute of Scientific and Technical Information of China (English)

    文双辉

    2014-01-01

    This paper deals with the method of non sensitive line determination of high content of copper lead zinc silver in Geological Samples by flame atomic absorption spectrometry, The optimum condi-tions for determination of each component are determined through ex-periment The working curve range 0-125 ug g/ ml,Determination of values and standard values,Component relative standard deviation (n=11) were lower than 1%, suitable for the determination of copper lead zinc silver in the range of 1%-15% samples.%本文研究了采用非灵敏线火焰原子吸收法测定地质样中较高含量的铜铅锌银的方法,通过实验确定了各组分测定的最佳条件。工作曲线范围0-125微克/毫升,测定值与标准值相吻合,各组分相对标准差(n=11)均低于1%,适合地质样品中较高含量铜铅锌银的测定。

  12. Lead in teeth from lead-dosed goats: Microdistribution and relationship to the cumulative lead dose

    International Nuclear Information System (INIS)

    Bellis, David J.; Hetter, Katherine M.; Jones, Joseph; Amarasiriwardena, Dula; Parsons, Patrick J.

    2008-01-01

    Teeth are commonly used as a biomarker of long-term lead exposure. There appear to be few data, however, on the content or distribution of lead in teeth where data on specific lead intake (dose) are also available. This study describes the analysis of a convenience sample of teeth from animals that were dosed with lead for other purposes, i.e., a proficiency testing program for blood lead. Lead concentration of whole teeth obtained from 23 animals, as determined by atomic absorption spectrometry, varied from 0.6 to 80 μg g -1 . Linear regression of whole tooth lead (μg g -1 ) on the cumulative lead dose received by the animal (g) yielded a slope of 1.2, with r 2 =0.647 (p -1 , were found in circumpulpal dentine. Linear regression of circumpulpal lead (μg g -1 ) on cumulative lead dose (g) yielded a slope of 23 with r 2 =0.961 (p=0.0001). The data indicated that whole tooth lead, and especially circumpulpal lead, of dosed goats increased linearly with cumulative lead exposure. These data suggest that circumpulpal dentine is a better biomarker of cumulative lead exposure than is whole tooth lead, at least for lead-dosed goats

  13. Ecotoxicology: Lead

    Science.gov (United States)

    Scheuhammer, A.M.; Beyer, W.N.; Schmitt, C.J.; Jorgensen, Sven Erik; Fath, Brian D.

    2008-01-01

    Lead (Pb) is a naturally occurring metallic element; trace concentrations are found in all environmental media and in all living things. However, certain human activities, especially base metal mining and smelting; combustion of leaded gasoline; the use of Pb in hunting, target shooting, and recreational angling; the use of Pb-based paints; and the uncontrolled disposal of Pb-containing products such as old vehicle batteries and electronic devices have resulted in increased environmental levels of Pb, and have created risks for Pb exposure and toxicity in invertebrates, fish, and wildlife in some ecosystems.

  14. Erythrocyte fluorescence and lead intoxication.

    Science.gov (United States)

    Clark, K G

    1976-01-01

    Blood samples from people exposed to inorganic lead were examined by fluorescence microscopy for excess erythrocyte porphyrin. With continued lead absorption, fluorescent erythrocytes appeared in the circulation of workers handling this metal or its compounds, and they progressively increased in number and brilliance. These changes ensued if the blood lead concentration was maintained above 2-42 mumol/l (50 mug/100 ml), and preceded any material fall in the haemoglobin value. At one factory, 62-5% of 81 symptomless workers showed erythrocyte fluorescence attributable to the toxic effects of lead. Excess fluorocytes were found in blood samples from a child with pica and three of her eight siblings. These four were subsequently shown to have slightly increased blood lead concentrations (2-03 to 2-32 mumol/l). Fluorescence microscopy for excess erythrocyte porphyrin is a sensitive method for the detection of chronic lead intoxication. A relatively slight increase in the blood lead is associated with demonstrabel changes in erythrocyte porphyrin content. The procedure requires little blood, and may be performed upon stored samples collected for lead estimation. The results are not readily influenced by contamination, and provide good confirmatory evidence for the absorption of biochemically active lead. PMID:963005

  15. Leading men

    DEFF Research Database (Denmark)

    Bekker-Nielsen, Tønnes

    2016-01-01

    Through a systematic comparison of c. 50 careers leading to the koinarchate or high priesthood of Asia, Bithynia, Galatia, Lycia, Macedonia and coastal Pontus, as described in funeral or honorary inscriptions of individual koinarchs, it is possible to identify common denominators but also disting...

  16. Vitamin A absorption

    International Nuclear Information System (INIS)

    Baker, S.J.

    1976-01-01

    Investigation of the absorption of vitamin A and related substances is complicated by the multiplicity of forms in which they occur in the diet and by the possibility that they may be subject to different mechanisms of absorption. Present knowledge of these mechanisms is inadequate, especially in the case of carotenoids. Numerous tests of absorption have been developed. The most common has been the biochemical measurement of the rise in plasma vitamin A after an oral dose of retinol or retinyl ester, but standardization is inadequate. Radioisotope tests based upon assay of serum or faecal activity following oral administration of tritiated vitamin A derivaties hold considerable promise, but again standardization is inadequate. From investigations hitherto performed it is known that absorption of vitamin A is influenced by several diseases, although as yet the consistency of results and the correlation with other tests of intestinal function have often been poor. However, the test of vitamin A absorption is nevertheless of clinical importance as a specialized measure of intestinal function. (author)

  17. Who Leads China's Leading Universities?

    Science.gov (United States)

    Huang, Futao

    2017-01-01

    This study attempts to identify the major characteristics of two different groups of institutional leaders in China's leading universities. The study begins with a review of relevant literature and theory. Then, there is a brief introduction to the selection of party secretaries, deputy secretaries, presidents and vice presidents in leading…

  18. Coherent single-photon absorption by single emitters coupled to 1D nanophotonic waveguides

    DEFF Research Database (Denmark)

    Chen, Yuntian; Wubs, Martijn; Mørk, Jesper

    2012-01-01

    We have derived an efficient model that allows calculating the dynamical single-photon absorption of an emitter coupled to a waveguide. We suggest a novel and simple structure that leads to strong single-photon absorption.......We have derived an efficient model that allows calculating the dynamical single-photon absorption of an emitter coupled to a waveguide. We suggest a novel and simple structure that leads to strong single-photon absorption....

  19. Lead pollution in Islamabad

    International Nuclear Information System (INIS)

    Mohammad, D.; Khatoon, N.; Ishaque, M.; Ahmed, I.

    1997-01-01

    Lead pollution of urban area emanating from the vehicular exhaust alone is being labeled as one of the worst form of environmental degradation attracting our attention for remediation. For factual assessment samples were collected from different areas of Islamabad. These samples consisted of tree scrapings / peelings, which were dried and ground before undertaking analysis for the lead content. The samples were digested with an acid mixture to remove the organic matter and analyzed using GFAAS technique. A total of 81 samples have been analyzed. The results sowed a lead content varying in the range of 8-474 Mu g g/sup -1/) and 23 samples with Pb content <50 Mu g g-1 (8.0-50.0 Mu g g/sup -1/). Most of the samples also contained some growth which consisted of bacterial, algae and fugal cells and the results have been explained on the basis of Pb absorption by these cells. The procedure followed in this study is recommended for evaluation of lead pollution in urban areas. (author)

  20. Porosity and liquid absorption of cement paste

    DEFF Research Database (Denmark)

    Krus, M.; Hansen, Kurt Kielsgaard; Kunzel, H. M.

    1997-01-01

    be a slowing-down effect which is related to water because the absorption of organic liquids, such as hexane, is quite normal. Measurements of the porosity of hardened cement paste determined by helium pycnometry and water saturation show that water molecules can enter spaces in the microstructure which...... are not accessible to the smaller helium atoms. Considering the results of dilatation tests both before and after water and hexane saturation, it seems possible that a contraction of capillary pores due to moisture-related swelling of the cement gel leads to the non-linear water absorption over the square root...

  1. Neutron resonance absorption theory

    International Nuclear Information System (INIS)

    Reuss, P.

    1991-11-01

    After some recalls on the physics of neutron resonance absorption during their slowing down, this paper presents the main features of the theoretical developments performed by the french school of reactor physics: the effective reaction rate method so called Livolant-Jeanpierre theory, the generalizations carried out by the author, and the probability table method [fr

  2. Noble gas absorption process

    International Nuclear Information System (INIS)

    Thomas, J.W.

    1975-01-01

    A method of removing a noble gas from air comprising the use of activated carbon filters in stages in which absorption and desorption steps in succession are conducted in order to increase the capacity of the filters is described. (U.S.)

  3. Total photon absorption

    International Nuclear Information System (INIS)

    Carlos, P.

    1985-01-01

    Experimental methods using real photon beams for measurements of total photonuclear absorption cross section σ(Tot : E/sub γ/) are recalled. Most recent σ(Tot : E/sub γ/)results for complex nuclei and in the nucleon resonance region are presented

  4. Chemical Absorption Materials

    DEFF Research Database (Denmark)

    Thomsen, Kaj

    2011-01-01

    Chemical absorption materials that potentially can be used for post combustion carbon dioxide capture are discussed. They fall into five groups, alkanolamines, alkali carbonates, ammonia, amino acid salts, and ionic liquids. The chemistry of the materials is discussed and advantages and drawbacks...

  5. Potential for phytoextraction of copper, lead, and zinc by rice (Oryza sativa L.), soybean (Glycine max [L.] Merr.), and maize (Zea mays L.).

    Science.gov (United States)

    Murakami, Masaharu; Ae, Noriharu

    2009-03-15

    Phytoextraction by hyperaccumulators has been proposed for decreasing toxic-metal concentrations of contaminated soils. However, hyperaccumulators have several shortcomings to introduce these species into Asian Monsoon's agricultural fields contaminated with low to moderate toxic-metals. To evaluate the phytoextraction potential, maize (Gold Dent), soybean (Enrei and Suzuyutaka), and rice (Nipponbare and Milyang 23) were pot-grown under aerobic soil conditions for 60d on the Andosol or Fluvisol with low to moderate copper (Cu), lead (Pb), and zinc (Zn) contamination. After 2 months cultivation, the Gold Dent maize and Milyang 23 rice shoots took up 20.2-29.5% and 18.5-20.2% of the 0.1molL(-1) HCl-extractable Cu, 10.0-37.3% and 8.5-34.3% of the DTPA-extractable Cu, and 2.4-6.5% and 2.1-5.9% of the total Cu, respectively, in the two soils. Suzuyutaka soybean shoot took up 23.0-29.4% of the 0.1molL(-1) HCl-extractable Zn, 35.1-52.6% of the DTPA-extractable Zn, and 3.8-5.3% of the total Zn in the two soils. Therefore, there is a great potential for Cu phytoextraction by the Gold Dent maize and the Milyang 23 rice and for Zn phytoextraction by the Suzuyutaka soybean from paddy soils with low to moderate contamination under aerobic soil conditions.

  6. UV laser long-path absorption spectroscopy

    Science.gov (United States)

    Dorn, Hans-Peter; Brauers, Theo; Neuroth, Rudolf

    1994-01-01

    Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive

  7. Numerical study of surface plasmon enhanced nonlinear absorption and refraction.

    Science.gov (United States)

    Kohlgraf-Owens, Dana C; Kik, Pieter G

    2008-07-07

    Maxwell Garnett effective medium theory is used to study the influence of silver nanoparticle induced field enhancement on the nonlinear response of a Kerr-type nonlinear host. We show that the composite nonlinear absorption coefficient, beta(c), can be enhanced relative to the host nonlinear absorption coefficient near the surface plasmon resonance of silver nanoparticles. This enhancement is not due to a resonant enhancement of the host nonlinear absorption, but rather due to a phase shifted enhancement of the host nonlinear refractive response. The enhancement occurs at the expense of introducing linear absorption, alpha(c), which leads to an overall reduced figure of merit beta(c)/alpha(c) for nonlinear absorption. For thin (< 1 microm) composites, the use of surface plasmons is found to result in an increased nonlinear absorption response compared to that of the host material.

  8. Hydrolysis Batteries: Generating Electrical Energy during Hydrogen Absorption.

    Science.gov (United States)

    Xiao, Rui; Chen, Jun; Fu, Kai; Zheng, Xinyao; Wang, Teng; Zheng, Jie; Li, Xingguo

    2018-02-19

    The hydrolysis reaction of aluminum can be decoupled into a battery by pairing an Al foil with a Pd-capped yttrium dihydride (YH 2 -Pd) electrode. This hydrolysis battery generates a voltage around 0.45 V and leads to hydrogen absorption into the YH 2 layer. This represents a new hydrogen absorption mechanism featuring electrical energy generation during hydrogen absorption. The hydrolysis battery converts 8-15 % of the thermal energy of the hydrolysis reaction into usable electrical energy, leading to much higher energy efficiency compared to that of direct hydrolysis. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Iron absorption studies

    International Nuclear Information System (INIS)

    Ekenved, G.

    1976-01-01

    The main objective of the present work was to study iron absorption from different iron preparations in different types of subjects and under varying therapeutic conditions. The studies were performed with different radioiron isotope techniques and with a serum iron technique. The preparations used were solutions of ferrous sulphate and rapidly-disintegrating tablets containing ferrous sulphate, ferrous fumarate and ferrous carbonate and a slow-release ferrous sulphate tablet of an insoluble matrix type (Duroferon Durules). The serum iron method was evaluated and good correlation was found between the serum iron response and the total amount of iron absorbed after an oral dose of iron given in solution or in tablet form. New technique for studying the in-vivo release properties of tablets was presented. Iron tablets labelled with a radio-isotope were given to healthy subjects. The decline of the radioactivity in the tablets was followed by a profile scanning technique applied to different types of iron tablets. The release of iron from the two types of tablets was shown to be slower in vivo than in vitro. It was found that co-administration of antacids and iron tablets led to a marked reduction in the iron absorption and that these drugs should not be administered sumultaneously. A standardized meal markedly decreased the absorbability of iron from iron tablets. The influence of the meal was more marked with rapidly-disintegrating than with slow-release ferrous sulphate tablets. The absorption from rapidly-disintegrating and slow-release ferrous sulphate tablets was compared under practical clinical conditions during an extended treatment period. The studies were performed in healthy subjects, blood donors and patients with iron deficiency anaemia and it was found that the absorption of iron from the slow-release tablets was significantly better than from the rapidly-disintegrating tablets in all three groups of subjects. (author)

  10. Gamma absorption meter

    International Nuclear Information System (INIS)

    Dincklage, R.D. von.

    1984-01-01

    The absorption meter consists of a radiation source, a trough for the absorbing liquid and a detector. It is characterized by the fact that there is a foil between the detector and the trough, made of a material whose binding energy of the K electrons is a little greater than the energy of the photons emitted by the radiation source. The source of radiation and foil are replaceable. (orig./HP) [de

  11. Total Absorption Spectroscopy

    International Nuclear Information System (INIS)

    Rubio, B.; Gelletly, W.

    2007-01-01

    The problem of determining the distribution of beta decay strength (B(GT)) as a function of excitation energy in the daughter nucleus is discussed. Total Absorption Spectroscopy is shown to provide a way of determining the B(GT) precisely. A brief history of such measurements and a discussion of the advantages and disadvantages of this technique, is followed by examples of two recent studies using the technique. (authors)

  12. Validation of the methodology for the quantitative determination of lead in cosmetics dyes available in the national market by atomic absorption spectroscopy with flame; Validacion de la metodologia para la determinacion cuantitativa de plomo en tintes cosmeticos disponibles en el mercado nacional por espectroscopia de absorcion atomica con llama

    Energy Technology Data Exchange (ETDEWEB)

    Silva Trejos, Paulina [Univ. de Costa Rica, Escuela de Quimica, telefono 2511-4870, fax 2253-5020 (Costa Rica)], E-mail: stpaulinita@gmail.com

    2008-07-15

    The analytical methodology was validated to quantify lead in cosmetics dyes available on the national market, by the method of atomic absorption spectroscopy with flame. The samples were digested by wet digestion with HNO{sub 3} to 65% m/m in a microwave oven, the percentage of recovery for the digestion of samples of 0,25 g and 0,45 g in 5,00 mL was of 100,5{+-}0,5. The field of optimal linearity detection limit was 5,0 mg/L with a correlation coefficient of 0,9998. The limits of detection and quantification limits determined graphically by the method of row errors for linear regression of 0,12{+-}0,02 mg/L and 0,21{+-}0,02 mg/L, respectively. Precision was evaluated determining the repeatability as standard deviation of five replicas of a positive dye for lead, according to the definition of the ISO, 2{radical}2*, and obtained a value of 2,3. The veracity was determined through percentages of recovery assessed, adding aliquots of lead patterns to dye samples and compared with the same mass to which they are not make additions. The dye samples were obtained at point of sale, such as pharmacies, beauty suppliers, supermarkets, sales of natural products and the central market of San Jose. The dyes tested contain lead acetates active ingredient, these are: Doni, Mont D'Or, Matador y Siempre Joven; they are produced locally, Youthair brand and American manufacturing. (author) [Spanish] La metodologia analitica fue validada para determinar cuantitativamente el plomo en tintes cosmeticos disponibles en el mercado nacional, por el metodo de espectroscopia de absorcion atomica con llama. Las muestras se dirigieron por digestion humeda con HNO{sub 3} al 65% m/m en horno de microondas; el porcentaje de recuperacion para la digestion de muestras de 0,25 g y 0,45 g en 5,00 mL fue de 100,5{+-}0,5. El ambito de linialidad optimo fue del limite de deteccion de 5,0 mg/L con un coeficiente de correlacion de 0,9998. Los limites de deteccion y los limites de cuantificacion

  13. Optical absorption in dendrimers

    International Nuclear Information System (INIS)

    Supritz, C.; Engelmann, A.; Reineker, P.

    2004-01-01

    Dendrimers are highly branched molecules, which are expected to be useful, for example, as efficient artificial light harvesting systems in nano-technological applications. There are two different classes of dendrimers: compact dendrimers with constant distance between neighboring branching points throughout the macromolecule and extended dendrimers, where this distance increases from the system periphery to the center. We investigate the linear absorption spectra of these dendrimer types using the Frenkel exciton concept. The electron-phonon interaction is taken into account by introducing a heat bath that interacts with the exciton in a stochastic manner

  14. Rapidly variable relatvistic absorption

    Science.gov (United States)

    Parker, M.; Pinto, C.; Fabian, A.; Lohfink, A.; Buisson, D.; Alston, W.; Jiang, J.

    2017-10-01

    I will present results from the 1.5Ms XMM-Newton observing campaign on the most X-ray variable AGN, IRAS 13224-3809. We find a series of nine absorption lines with a velocity of 0.24c from an ultra-fast outflow. For the first time, we are able to see extremely rapid variability of the UFO features, and can link this to the X-ray variability from the inner accretion disk. We find a clear flux dependence of the outflow features, suggesting that the wind is ionized by increasing X-ray emission.

  15. Metabolism of lead-210 in juvenile and adult rhesus monkeys (Macaca mulatta)

    International Nuclear Information System (INIS)

    Pounds, J.G.; Marlar, R.J.; Allen, J.R.

    1978-01-01

    Experiments were conducted measuring the gastrointestinal absorption and elimination of a single dose of lead-210 acetate in infant and adult rhesus monkeys. Urinary and fecal excretion of absorbed lead was followed for 23 days. Infant monkeys eliminated less and absorbed more orally administered lead. Adult animals excreted more absorbed lead in feces, while urinary excretion between adults and infants was similar. Increased absorption of administered lead and reduced fecal excretion of absorbed lead resulted in significantly greater body burden of lead-210 in infant animals. Blood lead values were increased in the infant animals, and were inversely correlated with body burden and percent absorption of ingested lead

  16. Reflection effect of localized absorptive potential on non-resonant and resonant tunneling

    International Nuclear Information System (INIS)

    Rubio, A.; Kumar, N.

    1992-06-01

    The reflection due to absorptive potential (-iV i ) for resonant and non-resonant tunneling has been considered. We show that the effect of reflection leads to a non-monotonic dependence of absorption on the strength V i with a maximum absorption of typically 0.5. This has implications for the operation of resonant tunneling devices. General conceptual aspects of absorptive potentials are discussed. (author). 9 refs, 2 figs

  17. Lead, arsenic, and copper content of crops grown on lead arsenate-treated and untreated soils

    Energy Technology Data Exchange (ETDEWEB)

    Chisholm, D

    1972-01-01

    Increased lead and arsenic concentrations in the surface soil (0-15 cm), resulting from applications of lead arsenate (PbHAs0/sub 1/), increased both lead and arsenic levels in crops grown on treated plots. The lead levels in some crops approached or exceeded the Canadian residue tolerance of 2.0 ppM. Lead arsenate soil treatments did not affect copper absorption by crops. On areas such as old orchard land contaminated with lead arsenate residues it may be advisable to ascertain crops, and also to determine the lead affinity and arsenic sensitivity of the plants to be grown.

  18. Lead exposure in adult males in urban Transvaal Province, South Africa during the apartheid era.

    Science.gov (United States)

    Hess, Catherine A; Cooper, Matthew J; Smith, Martin J; Trueman, Clive N; Schutkowski, Holger

    2013-01-01

    Human exposure to lead is a substantial public health hazard worldwide and is particularly problematic in the Republic of South Africa given the country's late cessation of leaded petrol. Lead exposure is associated with a number of serious health issues and diseases including developmental and cognitive deficiency, hypertension and heart disease. Understanding the distribution of lifetime lead burden within a given population is critical for reducing exposure rates. Femoral bone from 101 deceased adult males living in urban Transvaal Province (now Gauteng Province), South Africa between 1960 and 1998 were analyzed for lead concentration by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Of the 72 black and 29 white individuals sampled, chronic lead exposure was apparent in nearly all individuals. White males showed significantly higher median bone lead concentration (ME = 10.04 µg·g(-1)), than black males (ME = 3.80 µg·g(-1)) despite higher socioeconomic status. Bone lead concentration covaries significantly, though weakly, with individual age. There was no significant temporal trend in bone lead concentration. These results indicate that long-term low to moderate lead exposure is the historical norm among South African males. Unexpectedly, this research indicates that white males in the sample population were more highly exposed to lead.

  19. Exercise, Insulin Absorption Rates, and Artificial Pancreas Control

    Science.gov (United States)

    Frank, Spencer; Hinshaw, Ling; Basu, Rita; Basu, Ananda; Szeri, Andrew J.

    2016-11-01

    Type 1 Diabetes is characterized by an inability of a person to endogenously produce the hormone insulin. Because of this, insulin must be injected - usually subcutaneously. The size of the injected dose and the rate at which the dose reaches the circulatory system have a profound effect on the ability to control glucose excursions, and therefore control of diabetes. However, insulin absorption rates via subcutaneous injection are variable and depend on a number of factors including tissue perfusion, physical activity (vasodilation, increased capillary throughput), and other tissue geometric and physical properties. Exercise may also have a sizeable effect on the rate of insulin absorption, which can potentially lead to dangerous glucose levels. Insulin-dosing algorithms, as implemented in an artificial pancreas controller, should account accurately for absorption rate variability and exercise effects on insulin absorption. The aforementioned factors affecting insulin absorption will be discussed within the context of both fluid mechanics and data driven modeling approaches.

  20. Atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Haswell, S.J.

    1991-01-01

    Atomic absorption spectroscopy is now well established and widely used technique for the determination of trace and major elements in a wide range analyte types. There have been many advances in the atomic spectroscopy over the last decade and for this reason and to meet the demand, it was felt that there was a need for an updated book. Whilst interest in instrumental design has tended to dominate the minds of the spectrocopist, the analyst concerned with obtaining reliable and representative data, in diverse areas of application, has been diligently modifying and developing sample treatment and instrumental introduction techniques. Such methodology is de fundamental part of analysis and form the basis of the fourteen application chapters of this book. The text focuses in the main on AAS; however, the sample handling techniques described are in many cases equally applicable to ICP-OES and ICP-MS analysis. (author). refs.; figs.; tabs

  1. Atomic absorption spectrophotometer

    International Nuclear Information System (INIS)

    Stockdale, T. J.

    1985-01-01

    In atomic absorption spectrophotometer, a reference path may be provided for radiation which excludes the flame. This radiation provides a signal from a detector which varies only with the instrumental drift produced by variations in the radiation source brightness and by variations in detector gain. The signal can be used to compensate for drift in other signals received through a sample path including the flame. In the present invention, radiation passes through the sample path continuously during measurement, and only through the reference path between sample measurements. Movable mirrors shift the radiation between the paths upon externally applied commands. Conveniently, the reference path measurement is made while the flame is stabilized during the change between samples. The reference path measurements are stored and used to correct for drift

  2. Analyzing Water's Optical Absorption

    Science.gov (United States)

    2002-01-01

    A cooperative agreement between World Precision Instruments (WPI), Inc., and Stennis Space Center has led the UltraPath(TM) device, which provides a more efficient method for analyzing the optical absorption of water samples at sea. UltraPath is a unique, high-performance absorbance spectrophotometer with user-selectable light path lengths. It is an ideal tool for any study requiring precise and highly sensitive spectroscopic determination of analytes, either in the laboratory or the field. As a low-cost, rugged, and portable system capable of high- sensitivity measurements in widely divergent waters, UltraPath will help scientists examine the role that coastal ocean environments play in the global carbon cycle. UltraPath(TM) is a trademark of World Precision Instruments, Inc. LWCC(TM) is a trademark of World Precision Instruments, Inc.

  3. Atomic absorption spectrophotometry in perspective

    International Nuclear Information System (INIS)

    Soffiantini, V.

    1981-01-01

    Atomic absorption spectrophotometry is essentially an analytical technique used for quantitative trace metal analysis in a variety of materials. The speed and specificity of the technique is its greatest advantage over other analytical techniques. What atomic absorption spectrophotometry can and cannot do and its advantages and disadvantages are discussed, a summary of operating instructions are given, as well as a summary of analytical interferences. The applications of atomic absorption spectrophotometry are also shortly discussed

  4. Nonlinear effects in collective absorption

    International Nuclear Information System (INIS)

    Uenoyama, Takeshi; Mima, Kunioki; Watanabe, Tsuguhiro.

    1981-01-01

    The collective absorption of high intensity laser radiation is analyzed numerically. Density profile modification due to the ponderomotive force associating laser radiation and the excited electron plasma waves is self-consistently taken into account, and the intensity dependences of the absorption efficiency are obtained. In the high intensity regime, the absorption efficiency is found to be strongly enhanced in the plasma without flow, but reduced with supersonic flow. (author)

  5. X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  6. Frenkel defect absorption on dislocations and dislocation discharge rate. Modeling determination of the absorption zone

    International Nuclear Information System (INIS)

    Mikhlin, Eh.Ya.

    1988-01-01

    A situation connected with the fact that evaluations of dislocation discharge strength which somehow or other are based on the elasticity theory in the dislocation nucleus or near it, do not lead to results complying with experimental data, is discussed. Bases of the alternative approach to this problem consisting in direct investigation into the process of Frenkel defect absorption on dislocation by its computerized simulation at the microscopic level are also presented. Methods of investigation and results are described using α dislocation in iron-alpha as an example. The concept of zones of vacancy and interstitial atom absorption on dislocation is discussed. It is shown that a spontaneous transition, performed by any of these defects near a dislocation is not always identical to absorption and usually appears to be only a part of a multistage process leading to the defect disappearance. Potential relief characteristics for vacancy movement near the dislocation are found. An area wide enough in a transverse direction is found around the dislocation. Vacncies reaching this area can be easily transported to places of their disappearance. Therefore the vacancy entry to this area is equivalent to the absorption. the procedure of simulating the atomic structure of a crystallite containing a dislocation with a step is described. Positions from which these defects perform spontaneous transitions, reaching the disappearance places are found on the dislocation near the step

  7. Galactic absorption line coronae

    International Nuclear Information System (INIS)

    Bregman, J.N.

    1981-01-01

    We have investigated whether gaseous coronae around galaxies rise to the absorption systems seen in quasar spectra. In our model, gas originally located in the disk is heated to the million degree range and rises to surround the galaxy; the gas remains bound to the galaxy. Optically thin radiative cooling drives a thermal instability in the hot gas which causes cool clouds (T 4 K) to condense out of the corona. These clouds, which follow ballistic trajectories back to the disk, are the absorption sites. A two-dimensional hydrodynamic code with radiative cooling was used to study the dynamics and thermodynamics of the corona as well as the position rate at which clouds form. Coupled to the code is a galaxy with two mass components, a disk (approx.10 11 M/sub sun/) and a dark halo (approx.10 12 M/sub sun/). In a model where the temperature at the base of the corona (in the disk) is 3 x 10 6 K, absorbing gas of column density NL> or approx. =10 18 cm 2 extends radially to 100 kpc (face-on orientation) and vertically to 60 Kpc (edge-on orientation). The total mass of gas required here (coronal plus cloud gas) is 1.4 x 10 10 M/sub sun/, while the minimum supernova heating rate is one supernova per 27 years. In two other models (base coronal temperatures of 0.50 x 10 6 K and 1 x 10 6 K), coronal gas rises from an extended gaseous disk (in the previous model, the gas comes from a typical gaseous disk approximately 15 kpc in extent). Here, column densities of 10 19 cm -2 out to a radius of 70 kpc (face-on orientation) are achieved with a total gas mass of 1.7 x 10 9 M/sub direct-product/ and 2.0 x 10 9 M/sub sun/ and minimum heating rates of approximately one supernova per 170 years and one supernova per 60 years

  8. Bioavailability of lead in rats fed human diets

    International Nuclear Information System (INIS)

    Kostial, K.; Kello, D.

    1979-01-01

    The bioavailability of lead was studied in rats fed various baby foods (Babymix-turkey, Babymix-vegetables, Frutolino-fruit, Frutamix-bananas, Babyron-S-26, Truefood), cow's milk, bread, liver and standard rat diet. Lead absorption was determined by measuring the whole body retention of 203 Pb 6 days after a single oral application. Highest absorption values ranging from 17 to 20% were obtained in animals fed cow's milk and fruit foods. Rats on other human diets absorbed between 3 and 8% of the radioactive lead dose. Only in animals on rat diet lead absorption was below 1%. It is concluded that rats fed human diets show absorption values similar to those in humans. This might indicate that the bioavailability of lead is primarily dependent on dietary habits. This experimental model, if confirmed by further work, might be useful for obtaining preliminary data on the bioavailability of metals from various foods

  9. Wave energy absorption by ducks

    OpenAIRE

    Kurniawan, Adi

    2017-01-01

    We study the absorption of wave energy by a single and multiple cam-shaped bodies referred to as ducks. Numerical models are developed under the assumptions of linear theory. We consider wave absorption by a single duck as well as by two lines of ducks meeting at an angle.

  10. Wave energy absorption by ducks

    DEFF Research Database (Denmark)

    Kurniawan, Adi

    2018-01-01

    We study the absorption of wave energy by a single and multiple cam-shaped bodies referred to as ducks. Numerical models are developed under the assumptions of linear theory. We consider wave absorption by a single duck as well as by two lines of ducks meeting at an angle....

  11. Atomic absorption instrument functional description

    International Nuclear Information System (INIS)

    Bystroff, R.I.; Boyle, W.G. Jr.; Barton, G.W. Jr.

    1976-01-01

    This report describes a proposed system for automating atomic absorption analysis. The system consists of two atomic absorption instruments and an automatic sampler that can be attached to either instrument. A computer program controls the sampling and gathers data. The program then uses the data to perform bookkeeping, data processing, and report writing

  12. Sublinear absorption in OCS gas

    International Nuclear Information System (INIS)

    Bogani, F.; Querzoli, R.; Ernst, K.

    1988-01-01

    Sublinear absorption in OCS gas has been experimentally studied in detail by means of an optoacustic technique and transmission measurements. The best fit of the results is obtained by a phenomenological model, that considers the process as the sum of one-and two-photon absorptions

  13. Optical absorption of irradiated carbohydrates

    International Nuclear Information System (INIS)

    Supe, A.A.; Tiliks, Yu.E.

    1994-01-01

    The optical absorption spectra of γ-irradiated carbohydrates (glucose, lactose, sucrose, maltose, and starch) and their aqueous solutions were studied. The comparison of the data obtained with the determination of the concentrations of molecular and radical products of radiolysis allows the absorption bands with maxima at 250 and 310 nm to be assigned to the radicals trapped in the irradiated carbohydrates

  14. Water absorption in brick masonry

    NARCIS (Netherlands)

    Brocken, H.J.P.; Smolders, H.R.

    1996-01-01

    The water absorption in brick, mortar that was cured separately, and masonry samples was studied using NMR. Models of the moisture transport are usually formulated on the basis of a diffusion equation. In the case of water absorption in separate brick and mortar samples, the moisture diffusivity in

  15. Subgap absorption in conjugated polymers

    Energy Technology Data Exchange (ETDEWEB)

    Sinclair, M.; Seager, C.H. (Sandia National Labs., Albuquerque, NM (USA)); McBranch, D.; Heeger, A.J. (California Univ., Santa Barbara, CA (USA)); Baker, G.L. (Bell Communications Research, Inc., Red Bank, NJ (USA))

    1991-01-01

    Along with X{sup (3)}, the magnitude of the optical absorption in the transparent window below the principal absorption edge is an important parameter which will ultimately determine the utility of conjugated polymers in active integrated optical devices. With an absorptance sensitivity of < 10{sup {minus}5}, Photothermal Deflection Spectroscopy (PDS) is ideal for determining the absorption coefficients of thin films of transparent'' materials. We have used PDS to measure the optical absorption spectra of the conjugated polymers poly(1,4-phenylene-vinylene) (and derivitives) and polydiacetylene-4BCMU in the spectral region from 0.55 eV to 3 eV. Our spectra show that the shape of the absorption edge varies considerably from polymer to polymer, with polydiacetylene-4BCMU having the steepest absorption edge. The minimum absorption coefficients measured varied somewhat with sample age and quality, but were typically in the range 1 cm{sup {minus}1} to 10 cm{sup {minus}1}. In the region below 1 eV, overtones of C-H stretching modes were observed, indicating that further improvements in transparency in this spectral region might be achieved via deuteration of fluorination. 11 refs., 4 figs.

  16. Environmental lead exposure increases micronuclei in children

    DEFF Research Database (Denmark)

    Kapka, Lucyna; Baumgartner, Adolf; Siwińska, Ewa

    2007-01-01

    The objective of this pilot study was to investigate the contribution of environmental exposures to lead in the development of cytogenetic damage detected as the frequency of micronuclei (MN) in children. The other aim was to apply the MN assay in combination with fluorescence in situ hybridization...... age from an unexposed recreational area. Exposure to lead was assessed by determination of lead concentrations in blood (PbB) by atomic absorption spectrophotometry, whereas the level of selenium (Se) in serum was detected by using graphite furnace atomic-absorption spectrometry. The frequency of MN...... was determined by the cytokinesis-block MN assay and fluorescence in situ hybridization performed using a specific pan-centromeric probe. Environmental exposure to lead resulted in significantly increased levels of PbB (5.29 +/- 2.09 versus 3.45 +/- 1.20 microg/dl in controls), although the average level...

  17. Does low to moderate environmental exposure to noise and air pollution influence preterm delivery in medium-sized cities?

    Science.gov (United States)

    Barba-Vasseur, Marie; Bernard, Nadine; Pujol, Sophie; Sagot, Paul; Riethmuller, Didier; Thiriez, Gérard; Houot, Hélène; Defrance, Jérôme; Mariet, Anne-Sophie; Luu, Vinh-Phuc; Barbier, Alice; Benzenine, Eric; Quantin, Catherine; Mauny, Frédéric

    2017-12-01

    Preterm birth (PB) is an important predictor of childhood morbidity and educational performance. Beyond the known risk factors, environmental factors, such as air pollution and noise, have been implicated in PB. In urban areas, these pollutants coexist. Very few studies have examined the effects of multi-exposure on the pregnancy duration. The objective of this study was to analyse the relationship between PB and environmental chronic multi-exposure to noise and air pollution in medium-sized cities. A case-control study was conducted among women living in the city of Besançon (121 671 inhabitants) or in the urban unit of Dijon (243 936 inhabitants) and who delivered in a university hospital between 2005 and 2009. Only singleton pregnancies without associated pathologies were considered. Four controls were matched to each case in terms of the mother's age and delivery location. Residential noise and nitrogen dioxide (NO2) exposures were calculated at the mother's address. Conditional logistic regression models were applied, and sensitivity analyses were performed. This study included 302 cases and 1204 controls. The correlation between noise and NO2 indices ranged from 0.41 to 0.59. No significant differences were found in pollutant exposure levels between cases and controls. The adjusted odds ratios ranged between 0.96 and 1.08. Sensitivity analysis conducted using different temporal and spatial exposure windows demonstrated the same results. The results are in favour of a lack of connection between preterm delivery and multi-exposure to noise and air pollution in medium-sized cities for pregnant women without underlying disease. © The Author 2017; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association

  18. Caries experience among adults exposed to low to moderate doses of ionizing irradiation in childhood - the Tinea Capitis Cohort

    Directory of Open Access Journals (Sweden)

    Yuval eVered

    2016-02-01

    Full Text Available While the impact of therapeutic levels of ionizing radiation during childhood on dental defects has been documented, the possible effect of low doses on dental health is unknown. The study aims were to assess the association between childhood exposure to low-moderate doses of therapeutic radiation and caries experience among a cohort of adults 50 years following the exposure.The analysis was based on a sample of 253 irradiated (in the treatment of Tinea Capitis and 162 non-irradiated subjects. The DMFT (Decayed, Missing, and Filled Teeth index was assessed during a clinical dental examination and questions regarding dental care services utilization, oral hygiene behavior, current self-perceived mouth dryness, socio-demographic parameters and health behavior variables were obtained through a face to face interview.An ordered multivariate logistic regression model was used to assess the association of the main independent variable (irradiation status and other relevant independent variables on the increase in DMFT.Mean caries experience levels (DMFT were 18.6+7.5 for irradiated subjects compared to 16.4+7.2 for the non-irradiated (p=0.002. Controlling for gender, age, education, income, smoking, dental visit in the last year and brushing teeth behavior, irradiation was associated with a 72% increased risk for higher DMFT level (95% CI 1.19-2.50. A quantification of the risk by dose absorbed in the salivary gland and in the thyroid gland showed adjusted ORs of 2.21 per 1Gy (95% CI 1.40-3.50 and 1.05 per 1cGy (95% CI 1.01-1.09, respectively.Childhood exposure to ionizing radiation (0.2-0.4Gy might be associated with late outcomes of dental health. In line with the guidelines of the American Dental Association, these results call for caution when using dental radiographs.

  19. Methanol induces low temperature resilient methanogens and improves methane generation from domestic wastewater at low to moderate temperatures.

    Science.gov (United States)

    Saha, Shaswati; Badhe, Neha; De Vrieze, Jo; Biswas, Rima; Nandy, Tapas

    2015-01-01

    Low temperature (methanol is a preferred substrate by methanogens in cold habitats. The study hypothesizes that methanol can induce the growth of low-temperature resilient, methanol utilizing, hydrogenotrophs in UASB reactor. The hypothesis was tested in field conditions to evaluate the impact of seasonal temperature variations on methane yield in the presence and absence of methanol. Results show that 0.04% (v/v) methanol increased methane up to 15 times and its effect was more pronounced at lower temperatures. The qPCR analysis showed the presence of Methanobacteriales along with Methanosetaceae in large numbers. This indicates methanol induced the growth of both the hydrogenotrophic and acetoclastic groups through direct and indirect routes, respectively. This study thus demonstrated that methanol can impart resistance in methanogenic biomass to low temperature and can improve performance of UASB reactor. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Fusion-Related Ionization and Recombination Data for Tungsten Ions in Low to Moderately High Charge States

    Directory of Open Access Journals (Sweden)

    Alfred Müller

    2015-05-01

    Full Text Available Collisional processes and details of atomic structure of heavy many-electron atoms and ions are not yet understood in a fully satisfying manner. Experimental studies are required for guiding new theoretical approaches. In response to fusion-related needs for collisional and spectroscopic data on tungsten atoms in all charge states, a project has been initiated in which electron-impact and photon-induced ionization as well as photorecombination of Wq+ ions are studied. Cross sections and rate coefficients were determined for charge states q ranging from q = 1 to q = 5 for photoionization, for q = 1 up to q = 19 for electron-impact ionization and for q = 18 to q = 21 for electron-ion recombination. An overview, together with a critical assessment of the methods and results is provided.

  1. Regional TEC model under quiet geomagnetic conditions and low-to-moderate solar activity based on CODE GIMs

    Science.gov (United States)

    Feng, Jiandi; Jiang, Weiping; Wang, Zhengtao; Zhao, Zhenzhen; Nie, Linjuan

    2017-08-01

    Global empirical total electron content (TEC) models based on TEC maps effectively describe the average behavior of the ionosphere. However, the accuracy of these global models for a certain region may not be ideal. Due to the number and distribution of the International GNSS Service (IGS) stations, the accuracy of TEC maps is geographically different. The modeling database derived from the global TEC maps with different accuracy is likely one of the main reasons that limits the accuracy of the new models. Moreover, many anomalies in the ionosphere are geographic or geomagnetic dependent, and as such the accuracy of global models can deteriorate if these anomalies are not fully incorporated into the modeling approach. For regional models built in small areas, these influences on modeling are immensely weakened. Thus, the regional TEC models may better reflect the temporal and spatial variations of TEC. In our previous work (Feng et al., 2016), a regional TEC model TECM-NEC is proposed for northeast China. However, this model is only directed against the typical region of Mid-latitude Summer Nighttime Anomaly (MSNA) occurrence, which is meaningless in other regions without MSNA. Following the technique of TECM-NEC model, this study proposes another regional empirical TEC model for other regions in mid-latitudes. Taking a small area BeiJing-TianJin-Tangshan (JJT) region (37.5°-42.5° N, 115°-120° E) in China as an example, a regional empirical TEC model (TECM-JJT) is proposed using the TEC grid data from January 1, 1999 to June 30, 2015 provided by the Center for Orbit Determination in Europe (CODE) under quiet geomagnetic conditions. The TECM-JJT model fits the input CODE TEC data with a bias of 0.11TECU and a root mean square error of 3.26TECU. Result shows that the regional model TECM-JJT is consistent with CODE TEC data and GPS-TEC data.

  2. Characterization of Plasmodium vivax transmission-blocking activity in low to moderate malaria transmission settings of the Colombian Pacific coast.

    Science.gov (United States)

    Arévalo-Herrera, Myriam; Solarte, Yezid; Rocha, Leonardo; Alvarez, Diego; Beier, John C; Herrera, Sócrates

    2011-02-01

    Malaria infection induces antibodies capable of suppressing the infectivity of gametocytes and gametes, however, little is known about the duration of the antibody response, the parasite specificity, and the role of complement. We report the analyses of the transmission-blocking (TB) activity of sera collected from 105 Plasmodium vivax-infected and 44 non-infected individuals from a malaria endemic region of Colombia, using a membrane feeding assay in Anopheles albimanus mosquitoes. In infected donors we found that TB activity was antibody dose dependent (35%), lasted for 2-4 months after infection, and in 70% of the cases different P. vivax wild isolates displayed differential susceptibility to blocking antibodies. Additionally, in a number of assays TB was complement-dependent. Twenty-seven percent of non-infected individuals presented TB activity that correlated with antibody titers. Studies here provide preliminary data on factors of great importance for further work on the development of TB vaccines.

  3. Imputation Accuracy from Low to Moderate Density Single Nucleotide Polymorphism Chips in a Thai Multibreed Dairy Cattle Population

    Directory of Open Access Journals (Sweden)

    Danai Jattawa

    2016-04-01

    Full Text Available The objective of this study was to investigate the accuracy of imputation from low density (LDC to moderate density SNP chips (MDC in a Thai Holstein-Other multibreed dairy cattle population. Dairy cattle with complete pedigree information (n = 1,244 from 145 dairy farms were genotyped with GeneSeek GGP20K (n = 570, GGP26K (n = 540 and GGP80K (n = 134 chips. After checking for single nucleotide polymorphism (SNP quality, 17,779 SNP markers in common between the GGP20K, GGP26K, and GGP80K were used to represent MDC. Animals were divided into two groups, a reference group (n = 912 and a test group (n = 332. The SNP markers chosen for the test group were those located in positions corresponding to GeneSeek GGP9K (n = 7,652. The LDC to MDC genotype imputation was carried out using three different software packages, namely Beagle 3.3 (population-based algorithm, FImpute 2.2 (combined family- and population-based algorithms and Findhap 4 (combined family- and population-based algorithms. Imputation accuracies within and across chromosomes were calculated as ratios of correctly imputed SNP markers to overall imputed SNP markers. Imputation accuracy for the three software packages ranged from 76.79% to 93.94%. FImpute had higher imputation accuracy (93.94% than Findhap (84.64% and Beagle (76.79%. Imputation accuracies were similar and consistent across chromosomes for FImpute, but not for Findhap and Beagle. Most chromosomes that showed either high (73% or low (80% imputation accuracies were the same chromosomes that had above and below average linkage disequilibrium (LD; defined here as the correlation between pairs of adjacent SNP within chromosomes less than or equal to 1 Mb apart. Results indicated that FImpute was more suitable than Findhap and Beagle for genotype imputation in this Thai multibreed population. Perhaps additional increments in imputation accuracy could be achieved by increasing the completeness of pedigree information.

  4. The molecular kink paradigm for rubber elasticity: Numerical simulations of explicit polyisoprene networks at low to moderate tensile strains

    Science.gov (United States)

    Hanson, David E.

    2011-08-01

    Based on recent molecular dynamics and ab initio simulations of small isoprene molecules, we propose a new ansatz for rubber elasticity. We envision a network chain as a series of independent molecular kinks, each comprised of a small number of backbone units, and the strain as being imposed along the contour of the chain. We treat chain extension in three distinct force regimes: (Ia) near zero strain, where we assume that the chain is extended within a well defined tube, with all of the kinks participating simultaneously as entropic elastic springs, (II) when the chain becomes sensibly straight, giving rise to a purely enthalpic stretching force (until bond rupture occurs) and, (Ib) a linear entropic regime, between regimes Ia and II, in which a force limit is imposed by tube deformation. In this intermediate regime, the molecular kinks are assumed to be gradually straightened until the chain becomes a series of straight segments between entanglements. We assume that there exists a tube deformation tension limit that is inversely proportional to the chain path tortuosity. Here we report the results of numerical simulations of explicit three-dimensional, periodic, polyisoprene networks, using these extension-only force models. At low strain, crosslink nodes are moved affinely, up to an arbitrary node force limit. Above this limit, non-affine motion of the nodes is allowed to relax unbalanced chain forces. Our simulation results are in good agreement with tensile stress vs. strain experiments.

  5. The influence of aerobic exercise training on the double product break point in low-to-moderate risk adults.

    Science.gov (United States)

    Hargens, Trent A; Griffin, Diane C; Kaminsky, Leonard A; Whaley, Mitchell H

    2011-02-01

    The double product is the product of the heart rate and systolic blood pressure. The double product break point (DPBP) is a physiologic threshold that occurs at similar exercise intensities to that of the ventilatory threshold (VT). The influence of aerobic exercise training on the DPBP has not yet been examined. The purpose of this study was to examine whether aerobic exercise training (ET) increases the exercise intensity at which the DPBP occurs, and whether it increases in a similar fashion to the VT. Seven males and 11 females, all sedentary (mean ± SD: age = 29.9 ± 10.5 years) underwent supervised cardiopulmonary exercise testing using a cycle ergometer ramp protocol at baseline and after 8 weeks of vigorous ET on a cycle ergometer. The VT was determined by gas analysis and the V-slope method. Experienced observers using standardized instructions visually determined the DPBP. Following ET, VO(2 peak), maximal workload, and body composition variables all showed significant positive changes. The VO(2) at which the DPBP and VT occurred increased significantly from baseline to follow-up (P fashion to that of the VT, and may be an easier and more useful marker of the VT for exercise training purposes.

  6. THE PITTSBURGH SLOAN DIGITAL SKY SURVEY Mg II QUASAR ABSORPTION-LINE SURVEY CATALOG

    International Nuclear Information System (INIS)

    Quider, Anna M.; Nestor, Daniel B.; Turnshek, David A.; Rao, Sandhya M.; Weyant, Anja N.; Monier, Eric M.; Busche, Joseph R.

    2011-01-01

    We present a catalog of intervening Mg II quasar absorption-line systems in the redshift interval 0.36 ≤ z ≤ 2.28. The catalog was built from Sloan Digital Sky Survey Data Release Four (SDSS DR4) quasar spectra. Currently, the catalog contains ∼17, 000 measured Mg II doublets. We also present data on the ∼44, 600 quasar spectra which were searched to construct the catalog, including redshift and magnitude information, continuum-normalized spectra, and corresponding arrays of redshift-dependent minimum rest equivalent widths detectable at our confidence threshold. The catalog is available online. A careful second search of 500 random spectra indicated that, for every 100 spectra searched, approximately one significant Mg II system was accidentally rejected. Current plans to expand the catalog beyond DR4 quasars are discussed. Many Mg II absorbers are known to be associated with galaxies. Therefore, the combination of large size and well understood statistics makes this catalog ideal for precision studies of the low-ionization and neutral gas regions associated with galaxies at low to moderate redshift. An analysis of the statistics of Mg II absorbers using this catalog will be presented in a subsequent paper.

  7. Subgap Absorption in Conjugated Polymers

    Science.gov (United States)

    Sinclair, M.; Seager, C. H.; McBranch, D.; Heeger, A. J; Baker, G. L.

    1991-01-01

    Along with X{sup (3)}, the magnitude of the optical absorption in the transparent window below the principal absorption edge is an important parameter which will ultimately determine the utility of conjugated polymers in active integrated optical devices. With an absorptance sensitivity of materials. We have used PDS to measure the optical absorption spectra of the conjugated polymers poly(1,4-phenylene-vinylene) (and derivitives) and polydiacetylene-4BCMU in the spectral region from 0.55 eV to 3 eV. Our spectra show that the shape of the absorption edge varies considerably from polymer to polymer, with polydiacetylene-4BCMU having the steepest absorption edge. The minimum absorption coefficients measured varied somewhat with sample age and quality, but were typically in the range 1 cm{sup {minus}1} to 10 cm{sup {minus}1}. In the region below 1 eV, overtones of C-H stretching modes were observed, indicating that further improvements in transparency in this spectral region might be achieved via deuteration of fluorination.

  8. Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2014-01-01

    into random incidence absorption coefficients for porous absorbers are investigated. Two optimization-based conversion methods are suggested: the surface impedance estimation for locally reacting absorbers and the flow resistivity estimation for extendedly reacting absorbers. The suggested conversion methods...

  9. Optical absorption in disordered monolayer molybdenum disulfide

    Science.gov (United States)

    Ekuma, C. E.; Gunlycke, D.

    2018-05-01

    We explore the combined impact of sulfur vacancies and electronic interactions on the optical properties of monolayer MoS2. First, we present a generalized Anderson-Hubbard Hamiltonian that accounts for both randomly distributed sulfur vacancies and the presence of dielectric screening within the material. Second, we parametrize this energy-dependent Hamiltonian from first-principles calculations based on density functional theory and the Green's function and screened Coulomb (GW) method. Third, we apply a first-principles-based many-body typical medium method to determine the single-particle electronic structure. Fourth, we solve the Bethe-Salpeter equation to obtain the charge susceptibility χ with its imaginary part being related to the absorbance A . Our results show that an increased vacancy concentration leads to decreased absorption both in the band continuum and from exciton states within the band gap. We also observe increased absorption below the band-gap threshold and present an expression, which describes Lifshitz tails, in excellent qualitative agreement with our numerical calculations. This latter increased absorption in the 1.0 -2.5 eV range makes defect engineering of potential interest for solar cell applications.

  10. Absorption factor for cylindrical samples

    International Nuclear Information System (INIS)

    Sears, V.F.

    1984-01-01

    The absorption factor for the scattering of X-rays or neutrons in cylindrical samples is calculated by numerical integration for the case in which the absorption coefficients of the incident and scattered beams are not equal. An extensive table of values having an absolute accuracy of 10 -4 is given in a companion report [Sears (1983). Atomic Energy of Canada Limited, Report No. AECL-8176]. In the present paper an asymptotic expression is derived for the absorption factor which can be used with an error of less than 10 -3 for most cases of interest in both neutron inelastic scattering and neutron diffraction in crystals. (Auth.)

  11. Electrically tunable coherent optical absorption in graphene with ion gel.

    Science.gov (United States)

    Thareja, Vrinda; Kang, Ju-Hyung; Yuan, Hongtao; Milaninia, Kaveh M; Hwang, Harold Y; Cui, Yi; Kik, Pieter G; Brongersma, Mark L

    2015-03-11

    We demonstrate electrical control over coherent optical absorption in a graphene-based Salisbury screen consisting of a single layer of graphene placed in close proximity to a gold back reflector. The screen was designed to enhance light absorption at a target wavelength of 3.2 μm by using a 600 nm-thick, nonabsorbing silica spacer layer. An ionic gel layer placed on top of the screen was used to electrically gate the charge density in the graphene layer. Spectroscopic reflectance measurements were performed in situ as a function of gate bias. The changes in the reflectance spectra were analyzed using a Fresnel based transfer matrix model in which graphene was treated as an infinitesimally thin sheet with a conductivity given by the Kubo formula. The analysis reveals that a careful choice of the ionic gel layer thickness can lead to optical absorption enhancements of up to 5.5 times for the Salisbury screen compared to a suspended sheet of graphene. In addition to these absorption enhancements, we demonstrate very large electrically induced changes in the optical absorption of graphene of ∼3.3% per volt, the highest attained so far in a device that features an atomically thick active layer. This is attributable in part to the more effective gating achieved with the ion gel over the conventional dielectric back gates and partially by achieving a desirable coherent absorption effect linked to the presence of the thin ion gel that boosts the absorption by 40%.

  12. Exploring the origin of high optical absorption in conjugated polymers

    KAUST Repository

    Vezie, Michelle S.

    2016-05-16

    The specific optical absorption of an organic semiconductor is critical to the performance of organic optoelectronic devices. For example, higher light-harvesting efficiency can lead to higher photocurrent in solar cells that are limited by sub-optimal electrical transport. Here, we compare over 40 conjugated polymers, and find that many different chemical structures share an apparent maximum in their extinction coefficients. However, a diketopyrrolopyrrole-thienothiophene copolymer shows remarkably high optical absorption at relatively low photon energies. By investigating its backbone structure and conformation with measurements and quantum chemical calculations, we find that the high optical absorption can be explained by the high persistence length of the polymer. Accordingly, we demonstrate high absorption in other polymers with high theoretical persistence length. Visible light harvesting may be enhanced in other conjugated polymers through judicious design of the structure.

  13. Exploring the origin of high optical absorption in conjugated polymers

    KAUST Repository

    Vezie, Michelle S.; Few, Sheridan; Meager, Iain; Pieridou, Galatia; Dö rling, Bernhard; Ashraf, Raja Shahid; Goñ i, Alejandro R.; Bronstein, Hugo; McCulloch, Iain; Hayes, Sophia C.; Campoy-Quiles, Mariano; Nelson, Jenny

    2016-01-01

    The specific optical absorption of an organic semiconductor is critical to the performance of organic optoelectronic devices. For example, higher light-harvesting efficiency can lead to higher photocurrent in solar cells that are limited by sub-optimal electrical transport. Here, we compare over 40 conjugated polymers, and find that many different chemical structures share an apparent maximum in their extinction coefficients. However, a diketopyrrolopyrrole-thienothiophene copolymer shows remarkably high optical absorption at relatively low photon energies. By investigating its backbone structure and conformation with measurements and quantum chemical calculations, we find that the high optical absorption can be explained by the high persistence length of the polymer. Accordingly, we demonstrate high absorption in other polymers with high theoretical persistence length. Visible light harvesting may be enhanced in other conjugated polymers through judicious design of the structure.

  14. Using lamb waves tomonitor moisture absorption thermally fatigues composite laminates

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Sun; Cho, Youn Ho [School of Mechanical Engineering, Pusan National University, Busan (Korea, Republic of)

    2016-06-15

    Nondestructive evaluation for material health monitoring is important in aerospace industries. Composite laminates are exposed to heat cyclic loading and humid environment depending on flight conditions. Cyclic heat loading and moisture absorption may lead to material degradation such as matrix breaking, debonding, and delamination. In this paper, the moisture absorption ratio was investigated by measuring the Lamb wave velocity. The composite laminates were manufactured and subjected to different thermal aging cycles and moisture absorption. For various conditions of these cycles, not only changes in weight and also ultrasonic wave velocity were measured, and the Lamb wave velocity at various levels of moisture on a carbon-epoxy plate was investigated. Results from the experiment show a linear correlation between moisture absorption ratio and Lamb wave velocity at different thermal fatigue stages. The presented method can be applied as an alternative solution in the online monitoring of composite laminate moisture levels in commercial flights.

  15. OZONE ABSORPTION IN RAW WATERS

    Directory of Open Access Journals (Sweden)

    LJILJANA TAKIĆ

    2008-03-01

    Full Text Available The ozone absorption in raw water entering the main ozonization step at the Belgrade drinking water supply plant was investigated in a continuous stirred tank reactor (CSTR. A slow chemical reaction rate of dissolved ozone and pollutants present in raw water have been experimentally determined. The modified Hatta number was defined and calculated as a criterion which determines whether and to which extent the reactions of ozone and pollutants influence the rate of the pure physical ozone absorption.

  16. Microwaves absorption in superconducting materials

    International Nuclear Information System (INIS)

    Biasi, R.S. de; Fernandes, A.A.R.; Pereira, R.F.R.

    1989-01-01

    Microwaves absorption measures in two superconductors ceramics systems, Y-Ba-Cu-O and Bi-Sr-Ca-Cu-O are compared with similars datas obtained in the same band of temperature by a conventional method, mutual inductance. The results suggest that the microwaves absorption can be used as single and non-destructive method for investigating the properties of ceramics superconductors. (C.G.C.) [pt

  17. Lead-Cooled Fast Reactor Systems and the Fuels and Materials Challenges

    Directory of Open Access Journals (Sweden)

    T. R. Allen

    2007-01-01

    Full Text Available Anticipated developments in the consumer energy market have led developers of nuclear energy concepts to consider how innovations in energy technology can be adapted to meet consumer needs. Properties of molten lead or lead-bismuth alloy coolants in lead-cooled fast reactor (LFR systems offer potential advantages for reactors with passive safety characteristics, modular deployment, and fuel cycle flexibility. In addition to realizing those engineering objectives, the feasibility of such systems will rest on development or selection of fuels and materials suitable for use with corrosive lead or lead-bismuth. Three proposed LFR systems, with varying levels of concept maturity, are described to illustrate their associated fuels and materials challenges. Nitride fuels are generally favored for LFR use over metal or oxide fuels due to their compatibility with molten lead and lead-bismuth, in addition to their high atomic density and thermal conductivity. Ferritic/martensitic stainless steels, perhaps with silicon and/or oxide-dispersion additions for enhanced coolant compatibility and improved high-temperature strength, might prove sufficient for low-to-moderate-temperature LFRs, but it appears that ceramics or refractory metal alloys will be necessary for higher-temperature LFR systems intended for production of hydrogen energy carriers.

  18. Lead levels - blood

    Science.gov (United States)

    Blood lead levels ... is used to screen people at risk for lead poisoning. This may include industrial workers and children ... also used to measure how well treatment for lead poisoning is working. Lead is common in the ...

  19. Lead Poisoning Prevention Tips

    Science.gov (United States)

    ... or removed safely. How are children exposed to lead? Lead-based paint and lead contaminated dust are ... What can be done to prevent exposure to lead? It is important to determine the construction year ...

  20. Ultrasonic absorption in solid specimens

    International Nuclear Information System (INIS)

    Siwabessy, P.J. W.; Stewart, G.A.

    1996-01-01

    As part of a project to measure the absorption of high frequency (50 - 500 kHz) sonar signals in warm sea-water, a laboratory apparatus has been constructed and tested against room temperature distilled water and various solutions of MgSO 4 (chemical relaxation of MgSO 4 is the major contribution to absorption below 200 kHz). The technique involves monitoring the decay of an acoustic signal for different sizes of vessels of water suspended in an evacuated chamber. So far, all containing vessels used have been spherical in shape. Extrapolation of the results to infinite volume yields the absorption due to the water alone. In order to accommodate variations in temperature and pressure, and to make the system more robust (e.g. for ship deck usage), it is desirable to employ stainless steel vessels. However, it was found that the quality of the data was greatly improved when pyrex glass spheres were used. The stainless steel spheres were manufactured by welding together mechanically spun hemispheres. The linear frequency dependence characteristic of acoustic absorption in solids was observed (in contrast to the quadratic frequency dependence of acoustic absorption in water), and the acoustic absorption was found to depend strongly on the thermal history of the steel

  1. Atomic absorption assessment of mineral iron quantity in ferritin

    International Nuclear Information System (INIS)

    Marinova, M.; Vladimirova, L.

    2009-01-01

    Possibilities for quantitative determination of the number of iron atoms in the mineral core of ferritin by atomic absorption spectroscopy (AAS) are investigated in the work. Different measurements with AAS show an iron content from 1000 up to 4500 atoms per molecule ferritin. This motivated us to investigate the amount of iron in the Horse Spleen Ferritin with atomic absorption spectroscopy under application of the Bulgarian standard BDS EN 14082/2003 Foodstuffs - Determination of trace elements - Determination of lead, cadmium, zinc, copper, iron and chromium by atomic absorption spectrometry (AAS) after dry ashing. The obtained results give approx. 1800 atoms per molecule Ferritin. It is in accordance with previous results, published by leading researchers. The investigation of the iron content with AAS under the use of the Bulgarian standard is a good opportunity to study many other objects of biological interest. (authors)

  2. Lead accumulation in feathers of nestling black-crowned night-herons (Nycticorax nycticorax) experimentally treated in the field

    Science.gov (United States)

    Golden, N.H.; Rattner, B.A.; Cohen, J.B.; Hoffman, D.J.; Russek-Cohen, E.; Ottinger, M.A.

    2003-01-01

    Although lead can attain high concentrations in feathers, interpretation of the biological significance of this phenomenon is difficult. As part of an effort to develop and validate non-invasive methods to monitor contaminant exposure in free-ranging birds, lead uptake by feathers of nestling black-crowned night-herons (Nycticorax nycticorax) was evaluated in a controlled exposure study. Four to six day-old heron nestlings (one/nest) at Chincoteague Bay, Virginia, received a single intraperitoneal injection of dosing vehicle (control; n=7) or a dose of lead nitrate in water (0.01, 0.05, or 0.25 mg Pb/g body weight of nestling; n=6 or 7/dose) chosen to yield feather lead concentrations found at low to moderately polluted sites. Nestlings were euthanized at 15 days of age. Lead accumulation in feathers was associated with concentrations in bone, kidney, and liver (r = 0.32 - 0.74, p feather lead concentration. Culmen growth rate was depressed in nestlings treated with the highest dose of lead, but not correlated with feather lead concentration. These findings provide evidence that feathers of nestling herons are a sensitive indicator of lead exposure and have potential application for the extrapolation of lead concentrations in other tissues and the estimation of environmental lead exposure in birds.

  3. Lead accumulation in feathers of nestling black-crowned night herons (Nycticorax nycticorax) experimentally treated in the field.

    Science.gov (United States)

    Golden, Nancy H; Rattner, Barnett A; Cohen, Jonathan B; Hoffman, David J; Russek-Cohen, Estelle; Ottinger, Mary Ann

    2003-07-01

    Although lead can attain high concentrations in feathers, interpretation of the biological significance of this phenomenon is difficult. As part of an effort to develop and validate noninvasive methods to monitor contaminant exposure in free-ranging birds, lead uptake by feathers of nestling black-crowned night herons (Nycticorax nycticorax) was evaluated in a controlled exposure study. Four- to 6-d-old heron nestlings (one/nest) at Chincoteague Bay, Virginia (USA), received a single intraperitoneal injection of dosing vehicle (control, n = 7) or a dose of lead nitrate in water (0.01, 0.05, or 0.25 mg Pb/g body wt of nestling; n = 6 or 7/dose) chosen to yield feather lead concentrations found at low- to moderately polluted sites. Nestlings were euthanized at 15 d of age. Lead accumulation in feathers was associated with concentrations in bone, kidney, and liver (r = 0.32-0.74, p feather lead concentration. Culmen growth rate was depressed in nestlings treated with the highest dose of lead but not correlated with feather lead concentration. These findings provide evidence that feathers of nestling herons are a sensitive indicator of lead exposure and have potential application for the extrapolation of lead concentrations in other tissues and the estimation of environmental lead exposure in birds.

  4. Methods for deacidizing gaseous mixtures by phase enhanced absorption

    Science.gov (United States)

    Hu, Liang

    2012-11-27

    An improved process for deacidizing a gaseous mixture using phase enhanced gas-liquid absorption is described. The process utilizes a multiphasic absorbent that absorbs an acid gas at increased rate and leads to reduced overall energy costs for the deacidizing operation.

  5. Lead and cadmium content of spices

    Energy Technology Data Exchange (ETDEWEB)

    Bielig, H J; Dreyer, H; Askar, A

    1977-02-02

    The lead and cadmium content of various spices was determined by flameless atomic absorption (AAS). With the exception of one sample, the lead content was lower than 5 ppm, averaging a value of 2,2 ppm Pb. Thus, the maximum permissible level of 5 ppm Pb as recommended by different DIN standards, is not exceeded. The cadmium content was - except for one sample - lower than 0,5 ppm averaging a value of 0,23 ppm Cd. It can be assumed, that by spicing our dishes, the ingestion of lead and cadmium stays at a low level.

  6. Mortality study of lead workers

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, W C; Gaffey, W R

    1975-01-01

    The mortality of 7,032 men employed for one or more years in lead production facilities or battery plants was followed over a 23-year period, 1947-70. Lead absorption in many of these men was greatly in excess of currently accepted standards based upon urinary and blood lead concentrations available for a portion of the group. There were 1,356 deaths reported. The standardized mortality ratio (SMR) for all causes was 107 for smelter workers and 99 for battery plant workers. Death from neoplasms were in slight excess in smelters, but not significantly increased in battery plants. There were no excess deaths from kidney tumors. The SMR for cardiovascular-renal disease was 96 for smelter workers and 101 for battery plant workers. There was definitely no excess in deaths from either stroke or hypertensive heart disease; however, deaths classified as other hypertensive disease and unspecified nephritis or renal sclerosis were higher than expected. The life expectancy of lead workers was calculated to be approximately the same as that of all U.S. males.

  7. Lead in calcium supplements (abstract)

    International Nuclear Information System (INIS)

    Rehman, S.; Khalid, N.

    2011-01-01

    Lead present in calcium supplements is of grave concern as some lead levels have been measured up to the extent of regulatory limit set by the United States. Calcium supplements inevitably get contaminated with lead as both are naturally occurring elements. Therefore, it is imperative to indicate its level in these supplements in order to create awareness among consumers. In this study, a sophisticated analytical technique, atomic absorption spectrometry was used to analyze Pb contents in 27 commonly consumed Ca supplements manufactured by different national and multinational companies. The daily intake of lead through these supplements was calculated. Only 10% of the calcium supplements analyzed met the criteria of acceptable Pb levels (1.5 mu g/daily dose) in supplements/consumer products set by the United States. It was also found that Pb intake was highest in chelated calcium supplements 28.5 mu g/daily dose, whereas lowest 0.47 mu g/daily dose through calcium supplements with vitamin D formulation. In order to validate our results from the study conducted, IAEA-certified reference material (animal bone, H-5) was analyzed for its Pb levels. The levels of Pb determined were quite in good agreement with the certified values. (author)

  8. Optical absorption in SrC4H4O6·3H2O crystals

    International Nuclear Information System (INIS)

    Arora, S.K.; Patel, Vipul; Kothari, Anjana; Chudasama, Bhupendra

    2004-01-01

    Study of optical absorption in the gel-grown strontium tartrate trihydrate (STT) single crystals measured in UV-vis range at room temperature reveals transitions involving absorption and emission of phonons. Based on the theory of interband optical absorptions, the electronic transition near the fundamental absorption edge is analysed. Some feeble disorder in the crystal is conceived to be present. The analysis carried out hereunder leads to estimation of energy of the lattice phonons involved

  9. Lead accumulation in the straw mushroom, Volvariella volvacea, from lead contaminated rice straw and stubble.

    Science.gov (United States)

    Kumhomkul, Thapakorn; Panich-pat, Thanawan

    2013-08-01

    Straw mushrooms were grown on lead contaminated rice straw and stubble. Study materials were dried, acid digested, and analyzed for lead using flame atomic absorption spectrophotometry. The results showed the highest lead concentration in substrate was 445.350 mg kg⁻¹ in Treatment 3 (T3) and the lowest was BD (below detection) in Treatment 1 (T1). The maximum lead content in straw mushrooms was 5.072 mg kg⁻¹ dw in pileus of T3 and the minimum lead content in straw mushrooms was BD in egg and mature (stalk and pileus) stage of T1. The lead concentration in straw mushrooms was affected by the age of the mycelium and the morphology of mushrooms. Mushrooms' lead uptake produced the highest accumulation in the cell wall. Some lead concentrations in straw mushrooms exceeded the EU standard (>3 mg kg⁻¹ dw).

  10. Absorption properties of identical atoms

    International Nuclear Information System (INIS)

    Sancho, Pedro

    2013-01-01

    Emission rates and other optical properties of multi-particle systems in collective and entangled states differ from those in product ones. We show the existence of similar effects in the absorption probabilities for (anti)symmetrized states of two identical atoms. The effects strongly depend on the overlapping between the atoms and differ for bosons and fermions. We propose a viable experimental verification of these ideas. -- Highlights: •The absorption rates of a pair of identical atoms in product and (anti)symmetrized states are different. •The modifications of the optical properties are essentially determined by the overlapping between the atoms. •The absorption properties differ, in some cases, for bosons and fermions

  11. Transdermic absorption of Melagenina II

    International Nuclear Information System (INIS)

    Hernandez Gonzalez, I.; Martinez Lopez, B.; Ruiz Pena, M.; Caso Pena, R.

    1997-01-01

    The transdermic absorption of Melagenina II (MII) was evaluated. MII was a labelled with 125I by the yodogen method and purified by column chromatography with Sephadex LH-20 in ethanol: water (7:3). In vitro absorption of ( 125I ) - MII thought human skin was carried out in Keshary-Chien modified diffusion cells. Tape stripping method was applied after 24 hours to evaluate the accumulated activity in dermis and epidermis. In vivo assays were performed in Sprague Dawley rats to analyze absorption of MII until 24 hours after a single application and for five days a low penetrability of the drug while in vivo there were not found blood levels significantly greater than zero , nevertheless and important amount of radioactivity was found in feces and urine. The activity was concentrated mainly in the application site in both models

  12. Architecture for Absorption Based Heaters

    Science.gov (United States)

    Moghaddam, Saeed; Chugh, Devesh

    2018-04-24

    An absorption based heater is constructed on a fluid barrier heat exchanging plate such that it requires little space in a structure. The absorption based heater has a desorber, heat exchanger, and absorber sequentially placed on the fluid barrier heat exchanging plate. The vapor exchange faces of the desorber and the absorber are covered by a vapor permeable membrane that is permeable to a refrigerant vapor but impermeable to an absorbent. A process fluid flows on the side of the fluid barrier heat exchanging plate opposite the vapor exchange face through the absorber and subsequently through the heat exchanger. The absorption based heater can include a second plate with a condenser situated parallel to the fluid barrier heat exchanging plate and opposing the desorber for condensation of the refrigerant for additional heating of the process fluid.

  13. Mercury absorption in aqueous hypochlorite

    International Nuclear Information System (INIS)

    Zhao, L.L.; Rochelle, G.T.

    1999-01-01

    The absorption of elemental Hg vapor into aqueous hypochlorite was measured in a stirred tank reactor at 25 and 55C. NaOCl strongly absorbs Hg even at high pH. Low pH, high Cl - and high-temperature favor mercury absorption. Aqueous free Cl 2 was the active species that reacted with mercury. However, chlorine desorption was evident at high Cl - and pH 15 M -1 s -1 at 25C and 1.4x10 17 M -1 s -1 at 55C. Gas-phase reaction was observed between Hg and Cl 2 on apparatus surfaces. Strong mercury absorption in water was also detected with Cl 2 present. Results indicate that the chlorine concentration, moisture, and surface area contribute positively to mercury removal. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  14. Phytases for improved iron absorption

    DEFF Research Database (Denmark)

    Nielsen, Anne Veller Friis; Meyer, Anne S.

    2016-01-01

    Phytase enzymes present an alternative to iron supplements, because they have been shown to improve iron absorption by means of catalysing the degradation of a potent iron absorption inhibitor: phytic acid. Phytic acid is a hexaphosphate of inositol and is particularly prevalent in cereal grains......, where it serves as a storage molecule for phosphorous. Phytic acid is also associated with minerals. The minerals are bound by chelation to the negatively charged phosphate groups in phytic acid. Phytases catalyse the dephosphorylation of phytic acid, thus releasing bound minerals to make them available...... for absorption. This article presents research on phytase catalysis in gastric conditions and considers potential benefits and drawbacks for using phytases as a food supplement....

  15. Kinetic and diagnostic studies of molecular plasmas using laser absorption techniques

    NARCIS (Netherlands)

    Welzel, S.; Rousseau, A.; Davies, P.B.; Röpcke, J.

    2007-01-01

    Within the last decade mid infrared absorption spectroscopy between 3 and 20 µm, known as Infrared Laser Absorption Spectroscopy (IRLAS) and based on tuneable semiconductor lasers, namely lead salt diode lasers, often called tuneable diode lasers (TDL), and quantum cascade lasers (QCL) has

  16. Absorption-heat-pump system

    Science.gov (United States)

    Grossman, G.; Perez-Blanco, H.

    1983-06-16

    An improvement in an absorption heat pump cycle is obtained by adding adiabatic absorption and desorption steps to the absorber and desorber of the system. The adiabatic processes make it possible to obtain the highest temperature in the absorber before any heat is removed from it and the lowest temperature in the desorber before heat is added to it, allowing for efficient utilization of the thermodynamic availability of the heat supply stream. The improved system can operate with a larger difference between high and low working fluid concentrations, less circulation losses, and more efficient heat exchange than a conventional system.

  17. Absorption Efficiency of Receiving Antennas

    DEFF Research Database (Denmark)

    Andersen, Jørgen Bach; Frandsen, Aksel

    2005-01-01

    A receiving antenna with a matched load will always scatter some power. This paper sets an upper and a lower bound on the absorption efficiency (absorbed power over sum of absorbed and scattered powers), which lies between 0 and 100% depending on the directivities of the antenna and scatter...... patterns. It can approach 100% as closely as desired, although in practice this may not be an attractive solution. An example with a small endfire array of dipoles shows an efficiency of 93%. Several examples of small conical horn antennas are also given, and they all have absorption efficiencies less than...

  18. Lead (Pb) Air Pollution

    Science.gov (United States)

    ... Regional Offices Labs and Research Centers Lead (Pb) Air Pollution Contact Us Share As a result of EPA's ... and protect aquatic and terrestrial ecosystems. Lead (Pb) Air Pollution Basic Information How does lead get in the ...

  19. Association of Lead Levels and Cerebral Palsy

    Science.gov (United States)

    Bansal, Neha; Aggarwal, Anju; Faridi, M. M. A.; Sharma, Tusha; Baneerjee, B. D.

    2017-01-01

    Background: Cerebral palsy is a common motor disability in childhood. Raised lead levels affect cognition. Children with cerebral palsy may have raised lead levels, further impairing their residual cognitive motor and behavioral abilities. Environmental exposure and abnormal eating habits may lead to increased lead levels. Aims and Objectives: To measure blood lead levels in children with cerebral palsy and compare them with healthy neurologically normal children. To correlate blood lead levels with environmental factors. Material and Methods: Design: Prospective case-control study. Setting: Tertiary care hospital. Participants: Cases comprised 34 children with cerebral palsy, and controls comprised 34 neurologically normal, age- and sex-matched children. Methods: Clinical and demographic details were recorded as per proforma. Detailed environmental history was recorded to know the source of exposure to lead. These children were investigated and treated as per protocol. Venous blood was collected in ethylenediaminetetraacetic acid vials for analysis of blood lead levels. Lead levels were estimated by Schimadzu Flame AA-6800 (atomic absorption spectrophotometer). Data were analyzed using SPSS version 17. P pica were 12.33 ± 10.02 µg/dL in comparison to children with no history of pica, 6.70 ± 4.60 µg/dL (P = .029). No correlation was found between hemoglobin and blood lead levels in cases and controls. Conclusion: In our study, blood lead levels are raised in children with cerebral palsy. However, further studies are required to show effects of raised levels in these children. PMID:28491920

  20. Acoustic emission during hydrogen absorption and desorption in palladium

    International Nuclear Information System (INIS)

    Ramesh, R.; Mukhopadhyay, C.K.; Jayakumar, T.; Baldev Raj

    1996-01-01

    Acoustic emission technique has been used to study charging and discharging of hydrogen in palladium. During charging, breaking of oxide film due to surface activation and saturation of hydrogen absorption have been identified by acoustic emission. In the discharging cycle, the desorption of hydrogen from the specimen leads to high AE activity immediately after initiation of discharging, followed by gradual decrease in the acoustic activity, which reaches a minimum upon completion of the desorption. The potential of the acoustic emission technique for studying the kinetics of hydrogen absorption and desorption in metals has been shown. (author)

  1. Konference Distillation and Absorption 2010

    Czech Academy of Sciences Publication Activity Database

    Bendová, Magdalena

    2009-01-01

    Roč. 103, č. 10 (2009), s. 862 ISSN 0009-2770 R&D Projects: GA MŠk LA320 Institutional research plan: CEZ:AV0Z40720504 Keywords : conference * announcement * distillation and absorption Subject RIV: CF - Physical ; Theoretical Chemistry

  2. Gamm-ray absorption techniques

    International Nuclear Information System (INIS)

    Charlton, J.S.

    1986-01-01

    In this chapter the principles of gamma-ray absorption are described and important applications in plant and process techniques such as measurement of thickness of deposits on pipes, checking for voids in concrete, metal corrosion, measurement of the density of materials inside vessels in industrial radiography are discussed. (U.K.)

  3. Characteristics of transplacental lead transfer in rat dams and fetuses

    International Nuclear Information System (INIS)

    Kopfler, F.C.; Miller, R.G.; Kowal, N.E.; Kelty, K.C.; Doerger, J.U.; Mills, T.

    1987-01-01

    This study was designed to quantitate the dose resulting from lead exposure during the critical periods of brain development during gestation by determining: (1) if blood lead concentration in rat dams is affected by pregnancy status or duration of lead exposure, (2) if lead concentration in fetuses is associated with the duration of dam exposure, (3) the rates of lead absorption and elimination in pregnant and nonpregnant dams; and (4) the effect that prebreeding exposure on lead kinetics in the dam and upon fetus blood lead concentrations. The results of experiments in which the dams' drinking water contained 50 mg/L lead indicate blood lead levels (after normalizing by water consumption on a body weight basis) of pregnant rats are significantly higher than blood lead levels of non-pregnant rats. Statistical differences in blood lead levels were observed by day 15 of gestation and continue through day 20 of gestation. These blood lead differences are not due to lead treatment prior to breeding as seen when comparing Figure 1 and Figure 2. The blood lead levels of the fetuses at day 20 of gestation were 50-60% higher than that of the corresponding dams. The results from the latter two phases were ambiguous, due to large variability in individual animal absorption and elimination rates. However, the following observations can be made. Preexposure to lead does not affect the percent of lead transferred from the dams' blood to the fetuses. The rate of elimination of lead from the dams' blood does not appear to be affected by prebreeding exposure to lead or by the status of pregnancy. The fraction of the 203 Pb dose transferred to the fetus increases dramatically toward the end of gestation. The data suggest that lead absorption from the gut of pregnant rats is higher than that for nonpregnant rats

  4. Absorption and emission from mode conversion theory

    International Nuclear Information System (INIS)

    Swanson, D.G.

    1995-02-01

    The effects of mode conversion theory on emission have led to some surprising results. The classical expressions were originally derived from models which did not include mode conversion or its attendant reflection. When mode conversion was included, the first surprise was that the transmission coefficient is totally independent of absorption and due exclusively to tunneling. The other surprise is that the observed emission arises from two distinct sources, one direct, and one from an indirect Bernstein wave source which is partially converted in the cyclotron layer to outgoing electromagnetic waves, with the net result that mode conversion cancels out for the electron case. The only corrections to electron cyclotron emission are then due to reflection effects, and these have been shown to be small for laboratory plasmas, leading to the validation of the classical formula, but via an entirely new paradigm in its interpretation. This paper includes a summary of the absorption process for electron cyclotron harmonics, and reviews the emission physics, including both potential error estimates and a discussion of the spatial emission source distribution

  5. Fat absorption in cystic fibrosis mice is impeded by defective lipolysis and post-lipolytic events

    NARCIS (Netherlands)

    Bijvelds, MJC; Bronsveld, [No Value; Havinga, R; Sinaasappel, M; de Jonge, HR; Verkade, HJ

    Cystic fibrosis (CF) is frequently associated with progressive loss of exocrine pancreas function, leading to incomplete digestion and absorption of dietary fat. Supplementing patients with pancreatic lipase reduces fat excretion, but it does not completely correct fat malabsorption, indicating that

  6. Indirect measurement of lymphatic absorption in CAPD patients is not influenced by trapping

    NARCIS (Netherlands)

    Struijk, D. G.; Koomen, G. C.; Krediet, R. T.; Arisz, L.

    1992-01-01

    The disappearance rate of intraperitoneally administered macromolecules is often used to calculate lymphatic absorption during CAPD. The possible contribution of local accumulation (trapping) of such solutes in the tissues surrounding the peritoneal cavity, leading to overestimation of lymphatic

  7. Absorptive capacity and smart companies

    Directory of Open Access Journals (Sweden)

    Patricia Moro González

    2014-12-01

    Full Text Available Purpose: The current competitive environment is substantially modifying the organizations’ learning processes due to a global increase of available information allowing this to be transformed into knowledge. This opportunity has been exploited since the nineties by the tools of “Business Analytics” and “Business Intelligence” but, nevertheless, being integrated in the study of new organizational capacities engaged in the process of creating intelligence inside organizations is still an outstanding task. The review of the concept of absorptive capacity and a detailed study from the perspective of this new reality will be the main objective of study of this paper.Design/methodology/approach: By comparing classical absorptive capacity and absorptive capacity from the point of view of information management tools in each one of the three stages of the organizational learning cycle, some gaps of the former are overcome/fulfilled. The academic/bibliographical references provided in this paper have been obtained from ISI web of knowledge, Scopus and Dialnet data bases, supporting the state of affairs on absorptive capacity and thereafter filtering by "Business Intelligence" and "Business Analytics". Specialized websites and Business Schools` Publications there have also been included, crowning the content on information management tools used that are currently used in the strategic consulting.Findings: Our contribution to the literature is the development of "smart absorptive capacity". This is a new capacity emerging from the reformulation of the classical concept of absorptive capacity wherein some aspects of its definition that might have been omitted are emphasized. The result of this new approach is the creation of a new Theoretical Model of Organizational Intelligence, which aims to explain, within the framework of the Resources and Capabilities Theory, the competitive advantage achieved by the so-called smart companies

  8. Enhanced absorption of graphene in the visible region by use of plasmonic nanostructures

    DEFF Research Database (Denmark)

    Hashemi, Mahdieh; Farzad, Mahmood Hosseini; Mortensen, N. Asger

    2013-01-01

    Low absorption of graphene in the visible range of the spectrum makes it difficult to uniquely benefit from this material in ultra-fast optoelectronic applications. We numerically propose to utilize patterned metallic nanostructures to increase light absorption in single-layer graphene. Simulation...... results show that excitation of surface plasmon resonances in the metallic nanostructures significantly enhances the local electromagnetic field near the graphene layer, therefore leading to a dramatic enhancement of the absorption in the graphene layer itself. Broadband high optical absorption can...

  9. Lead induced dyslipidemia: The comparative effects of ascorbate ...

    African Journals Online (AJOL)

    R.N. UGBAJA

    2013-04-10

    Apr 10, 2013 ... metabolism in lead exposed rats, 35 male Wistar rats were used. They were grouped ... The blood lipid profiles were determined spectrophotometrically. Lead exposure ... Other significant sources include cosmetic products, food-can .... duplicates using a Thermo Scientific S Series Atomic Absorption.

  10. Photoluminescence Enhancement in Formamidinium Lead Iodide Thin Films

    NARCIS (Netherlands)

    Fang, Hong-Hua; Wang, Feng; Adjokatse, Sampson; Zhao, Ni; Loi, Maria Antonietta

    2016-01-01

    Formamidinium lead iodide (FAPbI(3)) has a broader absorption spectrum and better thermal stability than the most famous methylammonium lead iodide, thus exhibiting great potential for photovoltaic applications. In this report, the light-induced photoluminescence (PL) evolution in FAPbI(3) thin

  11. Cryogenic current leads

    Energy Technology Data Exchange (ETDEWEB)

    Zizek, F.

    1982-01-01

    Theoretical, technical and design questions are examined of cryogenic current leads for SP of magnetic systems. Simplified mathematical models are presented for the current leads. To illustrate modeling, the calculation is made of the real current leads for 500 A and three variants of current leads for 1500 A for the enterprise ''Shkoda.''

  12. Lead - nutritional considerations

    Science.gov (United States)

    ... billion people had toxic (poisonous) blood lead levels. Food Sources Lead can be found in canned goods if there is lead solder in the ... to bottled water for drinking and cooking. Avoid canned goods from foreign ... cans goes into effect. If imported wine containers have a lead foil ...

  13. Non-linear absorption in solids

    International Nuclear Information System (INIS)

    Brandi, H.S.; Jalbert, G.; Malta, O.L.

    1983-01-01

    Multiphoton transitions in direct-gap crystals are studied considering a 'non-perturbative' approach, similar to Keldysh approximation. A simple two parabolic band model in the effective mass approximation is considered. So that exact solutions associated to the full, crystal plus field, Hamiltonian may be approximated by Volkov wavefunctions. An S-matrix which incorporates the electromagnetic field to all orders in an approximated way is constructed leading to analytical solutions for the multiphoton transition rates. The use of the saddle-point method and its limitations as well as the connection between multiphoton absorption and tunneling is discussed. It is shown that for near threshold excitations the Keldysh approach is fairly accurate as long as terms arising from the saddle-point integration are consistently accounted. (Author) [pt

  14. Absorption of circularly polarized light by solids

    International Nuclear Information System (INIS)

    Jalbert, G.; Brandi, H.S.

    1984-03-01

    The multiphoton absorption rate of circularly polarized light, by direct gap crystals, was investigated following a non-perturbative scheme proposed by Jones and Reiss. It was possible to derive closed analytical solutions, for the N-photon transition rate, valid for all field strenghts of practical interest. The accuracy of the approximations introduced in deriving these results was determined comparing the numerical computations of the multiphoton transition rate ('exact') with the analytical solutions. Specific calculations are done for ZnS and GaAs in the presence of a Nd-laser. It is shown that this formalism leads to a total transition rate which has not the tunneling behavior previously discussed by several authors within similar contexts. (Author) [pt

  15. Non-linear absorption in solids

    International Nuclear Information System (INIS)

    Brandi, H.S.; Jalbert, G.; Malta, O.L.

    1983-06-01

    Multiphoton transitions in direct-gap crystals are studied considering a 'non-perturbative' approach, similar to Keldysh approximation. A simple two parabolic band model in the effective mass approximation is considered, so that exact solutions associate to the full, crystal plus field, Hamiltonian may be approximated by Volkov wavefunctions. In this manner an S matrix is constructed which incorporates the electromagnetic field to all orders in an approximated way, leading to analytical solutions for the multiphoton transition rates. The use of the saddle point method and its limitations as well as the connection between multiphoton absorption and tunneling is discussed. It is shown that the Keldysh approach is fairly accurate as long as terms arising from the saddle point integration are consistently accounted. (Author) [pt

  16. Converting Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2013-01-01

    are suggested: An optimization method for the surface impedances for locally reacting absorbers, the flow resistivity for extendedly reacting absorbers, and the flow resistance for fabrics. With four porous type absorbers, the conversion methods are validated. For absorbers backed by a rigid wall, the surface...... coefficients to random incidence absorption coefficients are proposed. The overestimations of the Sabine absorption coefficient are investigated theoretically based on Miki's model for porous absorbers backed by a rigid wall or an air cavity, resulting in conversion factors. Additionally, three optimizations...... impedance optimization produces the best results, while the flow resistivity optimization also yields reasonable results. The flow resistivity and flow resistance optimization for extendedly reacting absorbers are also found to be successful. However, the theoretical conversion factors based on Miki's model...

  17. Broadband solar absorption enhancement via periodic nanostructuring of electrodes.

    KAUST Repository

    Adachi, Michael M; Labelle, André J; Thon, Susanna M; Lan, Xinzheng; Hoogland, Sjoerd; Sargent, Edward H

    2013-01-01

    Solution processed colloidal quantum dot (CQD) solar cells have great potential for large area low-cost photovoltaics. However, light utilization remains low mainly due to the tradeoff between small carrier transport lengths and longer infrared photon absorption lengths. Here, we demonstrate a bottom-illuminated periodic nanostructured CQD solar cell that enhances broadband absorption without compromising charge extraction efficiency of the device. We use finite difference time domain (FDTD) simulations to study the nanostructure for implementation in a realistic device and then build proof-of-concept nanostructured solar cells, which exhibit a broadband absorption enhancement over the wavelength range of λ = 600 to 1,100 nm, leading to a 31% improvement in overall short-circuit current density compared to a planar device containing an approximately equal volume of active material. Remarkably, the improved current density is achieved using a light-absorber volume less than half that typically used in the best planar devices.

  18. Femtosecond laser irradiation-induced infrared absorption on silicon surfaces

    Directory of Open Access Journals (Sweden)

    Qinghua Zhu

    2015-04-01

    Full Text Available The near-infrared (NIR absorption below band gap energy of crystalline silicon is significantly increased after the silicon is irradiated with femtosecond laser pulses at a simple experimental condition. The absorption increase in the NIR range primarily depends on the femtosecond laser pulse energy, pulse number, and pulse duration. The Raman spectroscopy analysis shows that after the laser irradiation, the silicon surface consists of silicon nanostructure and amorphous silicon. The femtosecond laser irradiation leads to the formation of a composite of nanocrystalline, amorphous, and the crystal silicon substrate surface with microstructures. The composite has an optical absorption enhancement at visible wavelengths as well as at NIR wavelength. The composite may be useful for an NIR detector, for example, for gas sensing because of its large surface area.

  19. Absorption-reduced waveguide structure for efficient terahertz generation

    Energy Technology Data Exchange (ETDEWEB)

    Pálfalvi, L., E-mail: palfalvi@fizika.ttk.pte.hu [Institute of Physics, University of Pécs, Ifjúság ú. 6, 7624 Pécs (Hungary); Fülöp, J. A. [MTA-PTE High-Field Terahertz Research Group, Ifjúság ú. 6, 7624 Pécs (Hungary); Szentágothai Research Centre, University of Pécs, Ifjúság ú. 20, 7624 Pécs (Hungary); Hebling, J. [Institute of Physics, University of Pécs, Ifjúság ú. 6, 7624 Pécs (Hungary); MTA-PTE High-Field Terahertz Research Group, Ifjúság ú. 6, 7624 Pécs (Hungary); Szentágothai Research Centre, University of Pécs, Ifjúság ú. 20, 7624 Pécs (Hungary)

    2015-12-07

    An absorption-reduced planar waveguide structure is proposed for increasing the efficiency of terahertz (THz) pulse generation by optical rectification of femtosecond laser pulses with tilted-pulse-front in highly nonlinear materials with large absorption coefficient. The structure functions as waveguide both for the optical pump and the generated THz radiation. Most of the THz power propagates inside the cladding with low THz absorption, thereby reducing losses and leading to the enhancement of the THz generation efficiency by up to more than one order of magnitude, as compared with a bulk medium. Such a source can be suitable for highly efficient THz pulse generation pumped by low-energy (nJ-μJ) pulses at high (MHz) repetition rates delivered by compact fiber lasers.

  20. Broadband solar absorption enhancement via periodic nanostructuring of electrodes.

    KAUST Repository

    Adachi, Michael M

    2013-10-14

    Solution processed colloidal quantum dot (CQD) solar cells have great potential for large area low-cost photovoltaics. However, light utilization remains low mainly due to the tradeoff between small carrier transport lengths and longer infrared photon absorption lengths. Here, we demonstrate a bottom-illuminated periodic nanostructured CQD solar cell that enhances broadband absorption without compromising charge extraction efficiency of the device. We use finite difference time domain (FDTD) simulations to study the nanostructure for implementation in a realistic device and then build proof-of-concept nanostructured solar cells, which exhibit a broadband absorption enhancement over the wavelength range of λ = 600 to 1,100 nm, leading to a 31% improvement in overall short-circuit current density compared to a planar device containing an approximately equal volume of active material. Remarkably, the improved current density is achieved using a light-absorber volume less than half that typically used in the best planar devices.

  1. Lead and cadmium in food

    International Nuclear Information System (INIS)

    Gliesmann, S.; Kruse, H.; Kriews, M.; Mangels, H.

    1992-08-01

    The amounts of lead and cadmium produced and processed in these days are considerable. As a result, our environment is increasingly polluted by heavy metals and industrial installations, motor vehicles or incinerating plants appear to be among the main culprits here. Air and water are the media permitting the entry of heavy metals into our natural environment where they accumulate in the soil and then gradually migrate into the plants. Their further transport in the food constitutes the third step in the environmental spread of heavy metals. The consumption of muscle and organ meats, of vegetables, fruits, canned food and drinking water is unavoidably associated with some ingestion of lead and cadmium. The degree to which they are taken up and stored in different tissues is determined by absorption properties and the nutritional state of the organism. Cadmium tends to accumulate in the kidneys, lead is mainly stored in the bones. A continuously increasing uptake finally results in health injuries that range from unspecific complaints to damaged kidneys or bones and disorders of liver function. Children and elderly people are at a particular risk here. The level of food contamination is such that screening for heavy metals must be rigorously carried out once appropriate legal thresholds have been set, which ought to be based on proven detrimental effects of lead and cadmium on our health and also take account of infants and children or any other risk groups, where particular caution must be exercised. It should be pointed out that such thresholds have so far not been determined. (orig./MG) [de

  2. Correction to the Beer-Lambert-Bouguer law for optical absorption.

    Science.gov (United States)

    Abitan, Haim; Bohr, Henrik; Buchhave, Preben

    2008-10-10

    The Beer-Lambert-Bouguer absorption law, known as Beer's law for absorption in an optical medium, is precise only at power densities lower than a few kW. At higher power densities this law fails because it neglects the processes of stimulated emission and spontaneous emission. In previous models that considered those processes, an analytical expression for the absorption law could not be obtained. We show here that by utilizing the Lambert W-function, the two-level energy rate equation model is solved analytically, and this leads into a general absorption law that is exact because it accounts for absorption as well as stimulated and spontaneous emission. The general absorption law reduces to Beer's law at low power densities. A criterion for its application is given along with experimental examples. (c) 2008 Optical Society of America

  3. Enhanced index and negative dispersion without absorption in driven cascade media

    International Nuclear Information System (INIS)

    Hu Xiangming; Xu Jun

    2004-01-01

    In this paper we investigate the dispersive and absorptive properties of a system of three-level cascade atoms driven by a strong coherent field. Three characteristic features are found. First, for the same set of atom-light interaction parameters, the indices of refraction are large at three different frequencies where the absorption vanishes. These three frequencies are determined by the resonance transition frequencies between dressed states produced by the strong driving field. Second, negative dispersion without absorption, which leads to superluminal light propagation, is achievable in the central resonance structure of the dispersion spectrum. Third, the whole absorption spectrum displays, in general, three pairs of absorption peaks and three pairs of gain (negative absorption) peaks. The minimal spacing between dressed states determines whether the outer adjacent gain peaks are separated from each other

  4. Association of Lead Levels and Cerebral Palsy

    Directory of Open Access Journals (Sweden)

    Neha Bansal MD

    2017-03-01

    Full Text Available Background: Cerebral palsy is a common motor disability in childhood. Raised lead levels affect cognition. Children with cerebral palsy may have raised lead levels, further impairing their residual cognitive motor and behavioral abilities. Environmental exposure and abnormal eating habits may lead to increased lead levels. Aims and Objectives: To measure blood lead levels in children with cerebral palsy and compare them with healthy neurologically normal children. To correlate blood lead levels with environmental factors. Material and Methods: Design: Prospective case-control study. Setting: Tertiary care hospital. Participants: Cases comprised 34 children with cerebral palsy, and controls comprised 34 neurologically normal, age- and sex-matched children. Methods: Clinical and demographic details were recorded as per proforma. Detailed environmental history was recorded to know the source of exposure to lead. These children were investigated and treated as per protocol. Venous blood was collected in ethylenediaminetetraacetic acid vials for analysis of blood lead levels. Lead levels were estimated by Schimadzu Flame AA-6800 (atomic absorption spectrophotometer. Data were analyzed using SPSS version 17. P < .05 was taken as significant. Results: Mean blood lead levels were 9.20 ± 8.31 µg/dL in cerebral palsy cases and 2.89 ± 3.04 µg/dL in their controls (P < .001. Among children with cerebral palsy, 19 (55.88% children had blood lead levels ≥5 µg/dL. Lead levels in children with pica were 12.33 ± 10.02 µg/dL in comparison to children with no history of pica, 6.70 ± 4.60 µg/dL (P = .029. No correlation was found between hemoglobin and blood lead levels in cases and controls. Conclusion: In our study, blood lead levels are raised in children with cerebral palsy. However, further studies are required to show effects of raised levels in these children.

  5. Lead inclusions in aluminium

    International Nuclear Information System (INIS)

    Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.; Andersen, H.H.; Grabaek, L.; Bohr, J.

    1990-01-01

    Ion implantation at room temperature of lead into aluminum leads to spontaneous phase separation and formation of lead precipitates growing topotactically with the matrix. Unlike the highly pressurized (∼ 1-5 GPa) solid inclusions formed after noble gas implantations, the pressure in the lead precipitates is found to be less than 0.12 GPa. Recently the authors have observed the result that the lead inclusions in aluminum exhibit both superheating and supercooling. In this paper they review and elaborate on these results. Small implantation-induced lead precipitates embedded in an aluminum matrix were studied by x-ray diffraction

  6. Absorption/desorption in sprays

    International Nuclear Information System (INIS)

    Naimpally, A.

    1987-01-01

    This survey paper shall seek to present the present state of knowledge concerning absorption and desorption in spray chambers. The first part of the paper presents the theories and formulas for the atomization and break-up of sprays in nozzles. Formulas for the average (sauter-mean) diameters are then presented. For the case of absorption processes, the formulas for the dimensionless mass transfer coefficients is in drops. The total; mass transfer is the total of the transfer in individual drops. For the case of desorption of sparingly soluble gases from liquids in a spray chamber, the mass transfer occurs in the spray just at the point of break-up of the jet. Formulas for the desorption of gases are presented

  7. Bent Electro-Absorption Modulator

    DEFF Research Database (Denmark)

    2002-01-01

    by applying a variable electric or electronmagnetic field. The modulation of the complex refractive index results in a modulation of the refractive index contrast and the absorption coefficient for the waveguide at the frequency of the light. By carefully adjusting the composition of the semiconducting...... components and the applied electric field in relation to the frequency of the modulated radiation, the bending losses (and possibly coupling losses) will provide extinction of light guided by the bent waveguide section. The refractive index contract may be modulated while keeping the absorption coefficient......The present invention relates to a method and a device for modulating optical signals based on modulating bending losses in bend, quantum well semiconductor waveguide sections. The complex refractive index of the optical active semiconducting components of the waveguide section is modulated...

  8. Lead toxicity on hematological parameters in workers with occupational exposure to lead

    International Nuclear Information System (INIS)

    Dursun, N.; Koese, K.

    1998-01-01

    The effects of lead on hematological parameters were studied in lead exposed male workers occupied for 17.84+-4.22 years in a metal powder producing factory in Kayseri, Turkey and control male workers in same city. Blood lead and plasma zinc levels were measured by Atomic Absorption Spectrophotometry (AAS) and hematological parameters by Culture Counter S. The lead exposure workers had higher lead levels (13.81+- 9.21 mug/dl) as compared to control subjects (2.37+-0.10 mug/dl). No difference was observed in the plasma zinc levels of both groups. As indices of lead exposure, red blood cell (RBC) counts, hemoglobin (Hb), and hematocrit (Hct) values significantly decreased. Mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and mean corpuscular haemoglobin concentration (MCHC) significantly increased except MCV. There was also an increase in MCV, but it was not significant. (author)

  9. Geometrical interpretation of optical absorption

    Energy Technology Data Exchange (ETDEWEB)

    Monzon, J. J.; Barriuso, A. G.; Sanchez-Soto, L. L. [Departamento de Optica, Facultad de Fisica, Universidad Complutense, E-28040 Madrid (Spain); Montesinos-Amilibia, J. M. [Departamento de Geometria y Topologia, Facultad de Matematicas, Universidad Complutense, E-28040 Madrid (Spain)

    2011-08-15

    We reinterpret the transfer matrix for an absorbing system in very simple geometrical terms. In appropriate variables, the system appears as performing a Lorentz transformation in a (1 + 3)-dimensional space. Using homogeneous coordinates, we map that action on the unit sphere, which is at the realm of the Klein model of hyperbolic geometry. The effects of absorption appear then as a loxodromic transformation, that is, a rhumb line crossing all the meridians at the same angle.

  10. Modernization of Atomic Absorption Spectrophotometer

    International Nuclear Information System (INIS)

    Tasic, Visa; Milivojevic, Dragan; Karabasevic, Dejan

    2003-01-01

    In Copper Institute in Bor, connection has been made between absorption spectrophotometer and standard PC with the aim to make its operation more reliable and comfortable. Applied solution includes both software and hardware components. An I/O interface module has been installed in PC [1]. Software component consists of programs for measuring and interpretation of results. Paper presents details of this job realization.(Author)

  11. Turbulent effective absorptivity and refractivity

    International Nuclear Information System (INIS)

    Rax, J.M.

    1984-09-01

    The problem of wave propagation in a turbulent magnetized plasma is investigated. Considering small scale, low frequency density fluctuations we solve the Maxwell equations and show that the eikonal approximation remains valid with an effective refractivity and an effective absorptivity taking into account the energy diffusion due to the turbulent motion. Then the result is applied to the problem of lower hybrid waves scattering by drift waves density fluctuations in tokamaks

  12. Slowing down with resonance absorption

    International Nuclear Information System (INIS)

    Moura Neto, C. de; Nair, R.P.K.

    1979-08-01

    The presence of heavy nuclei in nuclear reactors, in significant concentrations, facilitates the appearance of absorption resonances. For the moderation in the presence of absorbers an exact solution of the integral equations is possible by numerical methods. Approximated solutions for separated resonances in function of the practical width, (NR and NRIM approximations) are discussed in this paper. The method is generalized, presenting the solution by an intermediate approximation, in the definition of the resonance integral. (Author) [pt

  13. Absorption and Metabolism of Xanthophylls

    OpenAIRE

    Kotake-Nara, Eiichi; Nagao, Akihiko

    2011-01-01

    Dietary carotenoids, especially xanthophylls, have attracted significant attention because of their characteristic biological activities, including anti-allergic, anti-cancer, and anti-obese actions. Although no less than forty carotenoids are ingested under usual dietary habits, only six carotenoids and their metabolites have been found in human tissues, suggesting selectivity in the intestinal absorption of carotenoids. Recently, facilitated diffusion in addition to simple diffusion has bee...

  14. Organizational forms and knowledge absorption

    Directory of Open Access Journals (Sweden)

    Radovanović Nikola

    2016-01-01

    Full Text Available Managing the entire portion of knowledge in an organization is a challenging task. At the organizational level, there can be enormous quantities of unknown, poorly valued or inefficiently applied knowledge. This is normally followed with the underdeveloped potential or inability of organizations to absorb knowledge from external sources. Facilitation of the efficient internal flow of knowledge within the established communication network may positively affect organizational capacity to absorb or identify, share and subsequently apply knowledge to commercial ends. Based on the evidences that the adoption of different organizational forms affects knowledge flows within an organization, this research analyzed the relationship between common organizational forms and absorptive capacity of organizations. In this paper, we test the hypothesis stating that the organizational structure affects knowledge absorption and exploitation in the organization. The methodology included quantitative and qualitative research method based on a questionnaire, while the data has been statistically analyzed and the hypothesis has been tested with the use of cross-tabulation and chi-square tests. The findings suggest that the type of organizational form affects knowledge absorption capacity and that having a less formalized and more flexible structure in an organization increases absorbing and exploiting opportunities of potentially valuable knowledge.

  15. Sub-band-gap absorption in Ga2O3

    Science.gov (United States)

    Peelaers, Hartwin; Van de Walle, Chris G.

    2017-10-01

    β-Ga2O3 is a transparent conducting oxide that, due to its large bandgap of 4.8 eV, exhibits transparency into the UV. However, the free carriers that enable the conductivity can absorb light. We study the effect of free carriers on the properties of Ga2O3 using hybrid density functional theory. The presence of free carriers leads to sub-band-gap absorption and a Burstein-Moss shift in the onset of absorption. We find that for a concentration of 1020 carriers, the Fermi level is located 0.23 eV above the conduction-band minimum. This leads to an increase in the electron effective mass from 0.27-0.28 me to 0.35-0.37 me and a sub-band-gap absorption band with a peak value of 0.6 × 103 cm-1 at 3.37 eV for light polarized along the x or z direction. Both across-the-gap and free-carrier absorption depend strongly on the polarization of the incoming light. We also provide parametrizations of the conduction-band shape and the effective mass as a function of the Fermi level.

  16. First studies of lead pollution in Guanabara

    International Nuclear Information System (INIS)

    Silveira Branquinho, C.L. da.

    1973-01-01

    The main sources of direct lead intake are studied, and metal concentrations in several medium are examined. Lead was extracted by dithizone in C Cl 4 , being determined by optical spectrophotometry. 2 1 2 Pb was used as a radioactive tracer in low concentration measurements of the metal, and analysis of its 239 KeV peak was done by a Ge-Li detector. In blood samples, the metal was complexed and extracted with APDC in MIBK, being measured by flame less atomic absorption spectrophotometry. Air samples were also collected for periods of 24 hours and 90 minutes. Representative street dust samples were examined, showing a strict correlation with lead in air. It was also estimated the amount of lead in some human blood samples. (author)

  17. Lead pollution, disease, and behaviour

    Energy Technology Data Exchange (ETDEWEB)

    Bryce-Smith, D; Waldron, H A

    1974-01-01

    Sources and health effects of atmospheric lead pollution are reviewed. Most of the Pb in gasoline is emitted in the exhaust gases as an aerosol containing particles of inorganic Pb. Some organic Pb is present, but the amount is usually less than 10% of the total. The size of these particles (0.18 to 0.90 micron) ensures maximum pulmonary penetration and absorption. The fallout of airborne particles produces very high concentrations of Pb in city dust, both inside and outside houses. Unpolluted soil contains about 15 ppM Pb, but samples of city dust contain 1000 to 6000 ppM. A daily intake of as little as 30 mg of dust containing 3% Pb produces clinical Pb poisoning in a few months. There is clear evidence to support the thesis that current levels in the environment are capable of producing behavioral abnormalities of types associated with educational disorders and delinquency, and also evidence that delinquents tend to have abnormal lead metabolism.

  18. VOLUMETRIC LEAD ASSAY

    International Nuclear Information System (INIS)

    Ebadian, M.A.; Dua, S.K.; Roelant, David; Kumar, Sachin

    2001-01-01

    This report describes a system for handling and radioassay of lead, consisting of a robot, a conveyor, and a gamma spectrometer. The report also presents a cost-benefit analysis of options: radioassay and recycling lead vs. disposal as waste

  19. NA49: lead-lead collision

    CERN Multimedia

    1996-01-01

    This is an image of an actual lead ion collision taken from tracking detectors on the NA49 experiment, part of the heavy ion project at CERN. These collisions produce a very complicated array of hadrons as the heavy ions break up. It is hoped that one of these collisions will eventually create a new state of matter known as quark-gluon plasma.

  20. Uranium-lead systematics

    International Nuclear Information System (INIS)

    Wickman, F.E.

    1983-01-01

    The method of Levchenkov and Shukolyukov for calculating age and time disturbance of minerals without correction for original lead is generalized to include the cases when (1) original lead and radiogenic lead leach differently, and (2) the crystals studied consist of a core and a mantle. It is also shown that a straight line obtained from the solution of the equations is the locus of the isotopic composition of original lead. (Auth.)

  1. A review of lung-to-blood absorption rates for radon progeny

    International Nuclear Information System (INIS)

    Marsh, J. W.; Bailey, M. R.

    2013-01-01

    The International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model (HRTM) treats clearance of materials from the respiratory tract as a competitive process between absorption into blood and particle transport to the alimentary tract and lymphatics. The ICRP recommended default absorption rates for lead and polonium (Type M) in ICRP Publication 71 but stated that the values were not appropriate for short-lived radon progeny. This paper reviews and evaluates published data from volunteer and laboratory animal experiments to estimate the HRTM absorption parameter values for short-lived radon progeny. Animal studies showed that lead ions have two phases of absorption: ∼10 % absorbed with a half-time of ∼15 min, the rest with a half-time of ∼10 h. The studies also indicated that some of the lead ions were bound to respiratory tract components. Bound fractions, f b , for lead were estimated from volunteer and animal studies and ranged from 0.2 to 0.8. Based on the evaluations of published data, the following HRTM absorption parameter values were derived for lead as a decay product of radon: f r = 0.1, s r = 100 d -1 , s s = 1.7 d -1 , f b = 0.5 and s b = 1.7 d -1 . Effective doses calculated assuming these absorption parameter values instead of a single absorption half-time of 10 h with no binding (as has generally been assumed) are only a few per cent higher. However, as there is some conflicting evidence on the absorption kinetics for radon progeny, dose calculations have been carried out for different sets of absorption parameter values derived from different studies. The results of these calculations are discussed. (authors)

  2. High Burden of Subclinical Lead Toxicity after Phase Out of Lead from Petroleum in Pakistan.

    Science.gov (United States)

    Majid, Hafsa; Khan, Aysha Habib; Khan, Nadeem Ullah; Siddiqui, Imran; Ghani, Farooq; Jafri, Lena

    2017-12-01

    To evaluate the frequency of subclinical lead toxicity. Cross-sectional study. Department of Pathology and Laboratory Medicine, The Aga Khan University Hospital, Karachi, from January 2011 to December 2014. Analysis of laboratory data for blood lead levels (BLL) was performed. Lead was tested by atomic absorption spectrometer. For all subjects, only initial test results were included while the results of repeated testing were excluded. Exemption was sought from institutional ethical review committee. BLL of 2-10 ug/dl and 10-70 ug/dl in children and adults, respectively were taken as subclinical lead toxicity. Amongst the total number of subjects tested (n=524), 26.5% (n=139) were children (lead level 16.9 ug/dl (36.1-4)] and lower level [4.2 ug/dl (6.8-2.6)] in children with lead levels while most had either subclinical (76%, n=106) or toxic lead levels (8%, n=11). In adults, (55%, n=212) subjects had desired lead levels, and 40% (n=154) and 4.99% (n=19) had subclinical and toxic lead levels. Presence of subclinical lead poisoning even after phasing out of lead petroleum in Pakistanis is alarming, especially in children. A national population-based study to determine the lead status and targeted intervention to identify potential sources is need of the time.

  3. Comparative toxicity of tetra ethyl lead and lead oxide to earthworms, Eisenia fetida (Savigny)

    International Nuclear Information System (INIS)

    Venkateswara Rao, J.; Kavitha, P.; Padmanabha Rao, A.

    2003-01-01

    Leaded gasoline contains tetra ethyl lead (TEL) as an antiknocking agent, which produces major amounts of lead oxide in automobile exhaust along with traces of TEL. To minimize the lead contamination, methyl tertiary butyl ether (MTBE) is used as a substitute for producing unleaded gasoline. It has become increasingly apparent that young children are highly susceptible to the harmful effects of lead. Hence, a study was carried out to monitor lead toxicity in soil, using adult earthworms (Eisenia fetida, Savigny). Leaded gasoline (TEL) and lead oxide are 383- and 211-fold more toxic than unleaded gasoline (MTBE) in 7 days of exposure and 627- and 290-fold more toxic in 14 days, respectively. Results indicate that the presence of TEL in leaded gasoline and lead oxide has a significant effect on behavior, morphology, and histopathology of earthworms. Absorption of TEL into the tissues is comparatively less than that of lead oxide but toxic effects were severe. Rupture of the cuticle, extrusion of coelomic fluid and inflexible metameric segmentation were observed, causing desensitization of the posterior region leading to fragmentation in earthworms

  4. Enriching Absorptive Capacity through Social Interaction

    NARCIS (Netherlands)

    Hotho, Jasper J.; Becker-Ritterspach, Florian; Saka-Helmhout, Ayse

    Absorptive capacity is frequently highlighted as a key determinant of knowledge transfer within multinational enterprises. But how individual behaviour translates into absorptive capacity at the subsidiary level, and how this is contingent on subsidiaries' social context, remains under-addressed.

  5. Hopping absorption edge in silicon inversion layers

    International Nuclear Information System (INIS)

    Kostadinov, I.Z.

    1983-09-01

    The low frequency gap observed in the absorption spectrum of silicon inversion layers is related to the AC variable range hopping. The frequency dependence of the absorption coefficient is calculated. (author)

  6. Atrioventricular Pacemaker Lead Reversal

    Directory of Open Access Journals (Sweden)

    Mehmet K Aktas, MD

    2007-01-01

    Full Text Available During cardiac surgery temporary epicardial atrial and ventricular leads are placed in case cardiac pacing is required postoperatively. We present the first reported series of patients with reversal of atrioventricular electrodes in the temporary pacemaker without any consequent deleterious hemodynamic effect. We review the electrocardiographic findings and discuss the findings that lead to the discovery of atrioventricular lead reversal.

  7. Lead Poisoning (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Lead Poisoning KidsHealth / For Parents / Lead Poisoning What's in ... Print en español La intoxicación por plomo About Lead Poisoning If you have young kids, it's important ...

  8. Optical and luminescent properties of the lead and barium molybdates

    Energy Technology Data Exchange (ETDEWEB)

    Spassky, D.A. E-mail: dima@opts.phys.msu.ru; Ivanov, S.N.; Kolobanov, V.N.; Mikhailin, V.V.; Zemskov, V.N.; Zadneprovski, B.I.; Potkin, L.I

    2004-12-01

    Time-resolved luminescence as well as excitation and reflectivity spectra of the oriented lead and barium molybdate single crystals were studied using synchrotron radiation. Features in reflectivity spectra in the fundamental absorption region were analyzed. The contribution of electronic states of lead cation to the formation of the bandgap in PbMoO{sub 4} is supposed. The role of lead states in the intrinsic luminescence of PbMoO{sub 4} is discussed.

  9. Evolution of absorption machines; Evolution des machines a absorption

    Energy Technology Data Exchange (ETDEWEB)

    Soide, I; Klemsdal, E [Gaz de France (GDF), 75 - Paris (France); Le Goff, P; Hornut, J M [LSGC-ENSIC, 54 - Nancy (France)

    1998-12-31

    Most of todays absorption air-conditioning machineries use the lithium bromide-water pair. The most performing can operate at a 150-160 deg. C, the temperature being limited by the corrosion resistance of metals with respect to LiBr solutions. Also, there is a revival of interest for water-ammonia systems. These systems require the use of a rectification column which reduces the coefficient of performance. Higher thermal performances are reached with hydrocarbon pairs and ternary mixtures (water-methanol-LiBr etc..). This paper presents different schemes of refrigerating heat pumps based on these different systems. (J.S.)

  10. Evolution of absorption machines; Evolution des machines a absorption

    Energy Technology Data Exchange (ETDEWEB)

    Soide, I.; Klemsdal, E. [Gaz de France (GDF), 75 - Paris (France); Le Goff, P.; Hornut, J.M. [LSGC-ENSIC, 54 - Nancy (France)

    1997-12-31

    Most of todays absorption air-conditioning machineries use the lithium bromide-water pair. The most performing can operate at a 150-160 deg. C, the temperature being limited by the corrosion resistance of metals with respect to LiBr solutions. Also, there is a revival of interest for water-ammonia systems. These systems require the use of a rectification column which reduces the coefficient of performance. Higher thermal performances are reached with hydrocarbon pairs and ternary mixtures (water-methanol-LiBr etc..). This paper presents different schemes of refrigerating heat pumps based on these different systems. (J.S.)

  11. Characteristics of water absorption of beans

    OpenAIRE

    上中, 登紀子; 森, 孝夫; 豊沢, 功; Tokiko, Uenaka; Takao, Mori; Isao, Toyosawa

    2001-01-01

    Characteristics of water absorption of soybean, azuki bean and kidney beans (cv. Toramame and Taishokintoki) were investigated. The way of water absorption of soybean was different from that of other beans, because soybeans absorbed water from whole surface of seed coat immediately after the immersion. Azuki beans absorbed extremely slowly water from only strophiole, and then the water absorption in other tissue was induced by a certain amount of water absorption playing a role of trigger. Th...

  12. Superconductivity in nanostructured lead

    Science.gov (United States)

    Lungu, Anca; Bleiweiss, Michael; Amirzadeh, Jafar; Saygi, Salih; Dimofte, Andreea; Yin, Ming; Iqbal, Zafar; Datta, Timir

    2001-01-01

    Three-dimensional nanoscale structures of lead were fabricated by electrodeposition of pure lead into artificial porous opal. The size of the metallic regions was comparable to the superconducting coherence length of bulk lead. Tc as high as 7.36 K was observed, also d Tc/d H was 2.7 times smaller than in bulk lead. Many of the characteristics of these differ from bulk lead, a type I superconductor. Irreversibility line and magnetic relaxation rates ( S) were also studied. S( T) displayed two maxima, with a peak value about 10 times smaller than that of typical high- Tc superconductors.

  13. Lactulose stimulates calcium absorption in postmenopausal women

    NARCIS (Netherlands)

    Heuvel, E.G.H.M. van den; Muijs, T.; Dokkum, W. van; Schaafsma, G.

    1999-01-01

    Animal studies have indicated that calcium absorption is increased by lactulose, a synthetic disaccharide. Therefore, the influence of lactulose on calcium absorption was measured in postmenopausal women who may benefit from the possible enhancing effect of lactulose on calcium absorption. Twelve

  14. Uniform semiclassical approximation for absorptive scattering systems

    International Nuclear Information System (INIS)

    Hussein, M.S.; Pato, M.P.

    1987-07-01

    The uniform semiclassical approximation of the elastic scattering amplitude is generalized to absorptive systems. An integral equation is derived which connects the absorption modified amplitude to the absorption free one. Division of the amplitude into a diffractive and refractive components is then made possible. (Author) [pt

  15. Iron absorption in relation to iron status

    International Nuclear Information System (INIS)

    Magnusson, B.; Bjoern-Rasmussen, E.; Hallberg, L.; Rossander, L.

    1981-01-01

    The absorption from a 3 mg dose of ferrous iron was measured in 250 male subjects. The absorption was related to the log concentration of serum ferritin in 186 subjects of whom 99 were regular blood donors (r= -0.76), and to bone marrow haemosiderin grading in 52 subjects with varying iron status. The purpose was to try and establish a percentage absorption from such a dose that is representative of subjects who are borderline iron deficient. This information is necessary for food iron absorption studies in order (1) to calculate the absorption of iron from the diet at a given iron status and (2) compare the absorption of iron from different meals studied in different groups of subjects by different investigarors. The results suggest that an absorption of about 40% of a 3 mg reference dose of ferrous iron is given in a fasting state, roughly corresponds to the absorption in borderline-iron-deficient subjects. The results indicate that this 40% absorption value corresponds to a serum ferritin level of 30 μg/l and that food iron absorption in a group of subjects should be expressed preferably as the absorption corresponding to a reference-dose absorption of 45%, or possibly a serum ferritin level of 30 μg/l. (author)

  16. Lead in the environment

    Science.gov (United States)

    Pattee, Oliver H.; Pain, Deborah J.; Hoffman, David J.; Rattner, Barnett A.; Burton, G. Allen; Cairns, John

    2003-01-01

    Anthropogenic uses of lead have probably altered its availability and environmental distribution more than any other toxic element. Consequently, lead concentrations in many living organisms may be approaching thresholds of toxicity for the adverse effects of lead. Such thresholds are difficult to define, as they vary with the chemical and physical form of lead, exposure regime, other elements present and also vary both within and between species. The technological capability to accurately quantify low lead concentrations has increased over the last decade, and physiological and behavioral effects have been measured in wildlife with tissue lead concentrations below those previously considered safe for humans.s.236 Consequently. lead criteria for the protection of wildlife and human health are frequently under review, and 'thresholds' of lead toxicity are being reconsidered. Proposed lead criteria for the protection of natural resources have been reviewed by Eisler. Uptake of lead by plants is limited by its generally low availability in soils and sediments, and toxicity may be limited by storage mechanisms and its apparently limited translocation within most plants. Lead does not generally accumulate within the foliar parts of plants, which limits its transfer to higher trophic levels. Although lead may concentrate in plant and animal tissues, no evidence of biomagnification exists. Acid deposition onto surface waters and soils with low buffering capacity may influence the availability of lead for uptake by plants and animals, and this may merit investigation at susceptible sites. The biological significance of chronic low-level lead exposure to wildlife is sometimes difficult to quantify. Animals living in urban environments or near point sources of lead emission are inevitably subject to greater exposure to lead and enhanced risk of lead poisoning. Increasingly strict controls on lead emissions in many countries have reduced exposure to lead from some sources

  17. Broadband absorption through extended resonance modes in random metamaterials

    International Nuclear Information System (INIS)

    Hao, J.; Niemiec, R.; Lheurette, É.; Lippens, D.; Burgnies, L.

    2016-01-01

    The properties of disordered metamaterial absorbers are analyzed on the basis of numerical simulations and experimental characterizations. A broadening of the absorption spectrum is clearly evidenced. This effect is the consequence of both the coupling between nearby resonators leading to the occurrence of extended magnetic resonance modes and the interconnection of elementary particles yielding the definition of resonating clusters. The angular robustness of the absorbing structure under oblique incidence is also demonstrated for a wide domain of angles.

  18. Lead poisoning in cattle and sheep

    Energy Technology Data Exchange (ETDEWEB)

    Allcroft, R

    1951-09-15

    The danger of paint and other lead compounds to the bovine is well recognized and has been recorded and discussed fairly extensively from time to time. The literature indicates that the calf is extremely susceptible to lead poisoning, but relatively little has been reported regarding the levels of lead in tissues of animals which have died as a result of lead poisoning, and still less in animals suspected of suffering from sub-lethal doses of lead compounds. In order to provide sufficient data to enable interpretation of figures obtained from tissues in cases of suspected lead poisoning sent in from the field, and to provide information on the metabolic fate of lead in ruminants, investigations were made at Weybridge on the absorption, excretion, retention and general metabolic effects of lead in both cattle and sheep and the results have been published in a series of five papers. In this brief review it is intended to discuss points from these and subsequent investigations which are likely to be of interest to the veterinarian.

  19. ALICE: Simulated lead-lead collision

    CERN Multimedia

    2003-01-01

    This track is an example of simulated data modelled for the ALICE detector on the Large Hadron Collider (LHC) at CERN, which will begin taking data in 2008. ALICE will focus on the study of collisions between nuclei of lead, a heavy element that produces many different particles when collided. It is hoped that these collisions will produce a new state of matter known as the quark-gluon plasma, which existed billionths of a second after the Big Bang.

  20. [The percutaneous absorption of diclofenac].

    Science.gov (United States)

    Riess, W; Schmid, K; Botta, L; Kobayashi, K; Moppert, J; Schneider, W; Sioufi, A; Strusberg, A; Tomasi, M

    1986-07-01

    The percutaneous absorption of diclofenac diethylammonium 1.16% (w/w) in a combination of emulsion cream and gel (Voltaren Emulgel) and of diclofenac sodium 1% (w/w) in a cream formulation (Voltaren cream) was investigated in guinea-pig, rabbit and man. The percutaneous absorption of diclofenac sodium in guinea-pig was 3 to 6% of the dose when the cream formulation in doses of 320, 100 or 40 mg was applied on 10 cm2 of occluded skin and left in place for 6 h. The transdermal delivery of 14C-labelled diclofenac yielded plateau plasma concentrations of radiotracer from 1.5 h after application until removal of the residual cream. Subsequently the steady state drug depots in the skin and muscle tissue were depleted promptly. During daily administration the steady state levels in the muscle tissue in proximity to the application site were about 3 times higher than in distant muscle tissue. By topical application on knee joints of rabbits diclofenac penetrated into the patellar ligament, the adipose corpus and the synovial fluid. In man the percutaneous absorption was 6% of the dose when the Emulgel formulation was spread by 5 mg/cm2 and left for 12 h on non-occluded skin. The pattern of metabolites of diclofenac in human urine was the same after topical and oral administration. In man, upon daily topical administration of 3 times 2.5 g cream formulation (10 mg/cm2) the diclofenac steady state plasma levels were 20 to 40 nmol/l.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Secondary lead production

    Energy Technology Data Exchange (ETDEWEB)

    Hollis, R.G.

    1990-10-16

    This invention is concerned with the efficient recovery of soft lead from the paste component of used automobile lead-acid storage batteries. According to the invention, a scrap which contains lead oxide, lead sulfate, and antimony in an oxidized state is processed in the following steps to recover lead. A refractory lined reaction vessel is continuously charged with the scrap, along with a reductant effective for reducing lead oxide. The charged material is melted and agitated by means of a submerged lance at 900-1150{degree}C whereby some of the lead oxide of the scrap is reduced to form molten lead. A slag layer is then formed above the molten lead, and an amount of lead oxide is maintained in the slag layer. The molten lead, now containing under 0.5 wt % of antimony, is removed, and the antimony oxide in the scrap is concentrated as oxide in the slag layer. Preferred embodiments of the invention result in the production, in a single step, of a soft lead substantially free of antimony. The slag may be subsequently treated to reduce the antimony oxide and produce a valuable antimony-lead product. Further advantages of the process are that a wet battery paste may be used as the feed without prior drying, and the process can be conducted at a temperature 100-150{degree}C lower than in previously known methods. In addition, a smaller reactor can be employed which reduces both capital cost and fuel costs. The process of the invention is illustrated by descriptions of pilot plant tests. 1 fig.

  2. Carbon Dioxide Absorption Heat Pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    2002-01-01

    A carbon dioxide absorption heat pump cycle is disclosed using a high pressure stage and a super-critical cooling stage to provide a non-toxic system. Using carbon dioxide gas as the working fluid in the system, the present invention desorbs the CO2 from an absorbent and cools the gas in the super-critical state to deliver heat thereby. The cooled CO2 gas is then expanded thereby providing cooling and is returned to an absorber for further cycling. Strategic use of heat exchangers can increase the efficiency and performance of the system.

  3. Phytases for Improved Iron Absorption

    DEFF Research Database (Denmark)

    Nielsen, Anne Veller Friis; Nyffenegger, Christian; Meyer, Anne S.

    2014-01-01

    Microbial phytases (EC 3.1.3.8) catalyse dephosphorylation of phytic acid, which is the primary storage compound for phosphorous in cereal kernels. The negatively charged phosphates in phytic acid chelate iron (Fe3+) and thus retards iron bioavailability in humans 1. Supplementation of microbial...... phytase can improve iron absorption from cereal-based diets 2. In order for phytase to catalyse iron release in vivo the phytase must be robust to low pH and proteolysis in the gastric ventricle. Our work has compared the robustness of five different microbial phytases, evaluating thermal stability...

  4. Iodine Absorption Cells Purity Testing

    Czech Academy of Sciences Publication Activity Database

    Hrabina, Jan; Zucco, M.; Philippe, Ch.; Pham, Minh Tuan; Holá, Miroslava; Acef, O.; Lazar, Josef; Číp, Ondřej

    2017-01-01

    Roč. 17, č. 1 (2017), s. 1-13, č. článku 17010102. ISSN 1424-8220 R&D Projects: GA ČR GA15-18430S; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : iodine cells * absorption spectroscopy * laser spectroscopy * laser standards * frequency stability Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 2.677, year: 2016

  5. Microwave Absorption Characteristics of Tire

    Science.gov (United States)

    Zhang, Yuzhe; Hwang, Jiann-Yang; Peng, Zhiwei; Andriese, Matthew; Li, Bowen; Huang, Xiaodi; Wang, Xinli

    The recycling of waste tires has been a big environmental problem. About 280 million waste tires are produced annually in the United States and more than 2 billion tires are stockpiled, which cause fire hazards and health issues. Tire rubbers are insoluble elastic high polymer materials. They are not biodegradable and may take hundreds of years to decompose in the natural environment. Microwave irradiation can be a thermal processing method for the decomposition of tire rubbers. In this study, the microwave absorption properties of waste tire at various temperatures are characterized to determine the conditions favorable for the microwave heating of waste tires.

  6. Lead sulfide nano crystal preparation and characterization

    International Nuclear Information System (INIS)

    Sasani Ghamsari, M.

    1999-01-01

    Nanometer sized semiconductor particles have attracted much attention duo to their novel electronic and optical optical proportion, originating from quantum confinement. Pb S is one of the most important semiconductor material. In this project Pb S semiconductor nano crystal is synthesized in order to decrease particle size and study the modifications of their optical properties in relation to their size. The synthesis is carried out by using the technique of colloid chemistry. In this method we use lead nitrate extra pure and H2 S gas which is solved in the water. EDTA is used for controlling of particle size. A fast evolution of the optical absorption spectrum will be noticed following synthesis. Immediately after the synthesis reaction. The sample, exhibit a structured absorption spectrum with well defined excitonic peak in 240 nm theoretical relations is that shown this peak belong to 5 A particles. X-ray diffraction is used to establish the identity, phase and the size of these clusters

  7. Lead-Free Piezoelectrics

    CERN Document Server

    Nahm, Sahn

    2012-01-01

    Ecological restrictions in many parts of the world are demanding the elimination of Pb from all consumer items. At this moment in the piezoelectric ceramics industry, there is no issue of more importance than the transition to lead-free materials. The goal of Lead-Free Piezoelectrics is to provide a comprehensive overview of the fundamentals and developments in the field of lead-free materials and products to leading researchers in the world. The text presents chapters on demonstrated applications of the lead-free materials, which will allow readers to conceptualize the present possibilities and will be useful for both students and professionals conducting research on ferroelectrics, piezoelectrics, smart materials, lead-free materials, and a variety of applications including sensors, actuators, ultrasonic transducers and energy harvesters.

  8. Lead Poison Detection

    Science.gov (United States)

    1976-01-01

    With NASA contracts, Whittaker Corporations Space Science division has developed an electro-optical instrument to mass screen for lead poisoning. Device is portable and detects protoporphyrin in whole blood. Free corpuscular porphyrins occur as an early effect of lead ingestion. Also detects lead in urine used to confirm blood tests. Test is inexpensive and can be applied by relatively unskilled personnel. Similar Whittaker fluorometry device called "drug screen" can measure morphine and quinine in urine much faster and cheaper than other methods.

  9. Iodine Absorption Cells Purity Testing

    Directory of Open Access Journals (Sweden)

    Jan Hrabina

    2017-01-01

    Full Text Available This article deals with the evaluation of the chemical purity of iodine-filled absorption cells and the optical frequency references used for the frequency locking of laser standards. We summarize the recent trends and progress in absorption cell technology and we focus on methods for iodine cell purity testing. We compare two independent experimental systems based on the laser-induced fluorescence method, showing an improvement of measurement uncertainty by introducing a compensation system reducing unwanted influences. We show the advantages of this technique, which is relatively simple and does not require extensive hardware equipment. As an alternative to the traditionally used methods we propose an approach of hyperfine transitions’ spectral linewidth measurement. The key characteristic of this method is demonstrated on a set of testing iodine cells. The relationship between laser-induced fluorescence and transition linewidth methods will be presented as well as a summary of the advantages and disadvantages of the proposed technique (in comparison with traditional measurement approaches.

  10. Lead intoxication in dogs: risk assessment of feeding dogs trimmings of lead-shot game.

    Science.gov (United States)

    Høgåsen, Helga R; Ørnsrud, Robin; Knutsen, Helle K; Bernhoft, Aksel

    2016-07-25

    Expanding lead-based bullets, commonly used for hunting of big game, produce a scattering of lead particles in the carcass around the wound channel. Trimmings around this channel, which are sometimes fed to dogs, may contain lead particles. The aim of this study was to assess potential health effects of feeding dogs such trimmings. Lead ingestion most commonly causes gastrointestinal and neurological clinical signs, although renal, skeletal, haematological, cardiovascular and biochemical effects have also been reported. Experimental data indicate that a daily dose of around 1 mg lead as lead acetate/kg body weight for ten days may be considered as a Lowest Observed Effect Level in dogs. Acute toxicity documentation from the Centers for Disease Control and Prevention indicates 300 mg/kg body weight as the lowest dose of lead acetate causing death in dogs after oral ingestion. Our assessment suggests that dogs fed trimmings of lead-shot game may be affected by the amounts of lead present, and that even deadly exposure could occasionally occur. The intestinal absorption of lead from bullets was assumed to be 10-80 % of that of lead acetate, reflecting both the variability in particle size and uncertainty about the bioavailability of metallic lead in dogs. Despite data gaps, this study indicates that feeding dogs trimmings of lead-shot game may represent a risk of lead intoxication. More research is needed to assess the exact consequences, if lead-based bullets are still to be used. Meanwhile, we recommend that trimmings close to the wound channel should be made inaccessible to dogs, as well as to other domestic or wild animals.

  11. Effect on blood lead of airborne lead particles characterized by size.

    Science.gov (United States)

    Park, Dong-Uk; Paik, Nam-Won

    2002-03-01

    Worker exposure to airborne lead particles was evaluated for a total of 117 workers in 12 work-places of four different industrial types in Korea. The particle sizes were measured using 8-stage cascade impactors worn by the workers. Mass median aerodynamic diameters (MMAD) were determined by type of industry and percentage of lead particles as a fraction of airborne lead (PbA) concentration was determined by particle size. Blood lead (PbB) levels of workers who matched airborne lead samples were also examined. A Scheffé's pairwise comparison test showed that MMAD and the fractions of each of respirable particles and lead particles lead particles lead particles (r = 0.82) than that between concentrations of small particles and PbA (r = 0.61). A simple linear regression indicated that PbB correlated better with respirable lead concentration (r2 = 0.35, P = 0.0001) than with PbA concentration and had a higher slope coefficient. Controlling for respirable lead concentration reduced the partial correlation coefficient between PbA concentration and PbB level from 0.56 to 0.20 (P = 0.053). The results indicate that the contribution of respirable lead particles to lead absorption would be greater than that of PbA. This study concludes that the measurement of PbA only may not properly reflect a worker's exposure to lead particles with diverse characteristics. For the evaluation of a worker's exposure to various types of lead particles, it is recommended that respirable lead particles as well as PbA be measured.

  12. Light absorption in thin quantizing semiconductor wires with non-parabolic law of dispersion of charge carriers

    International Nuclear Information System (INIS)

    Djotian, A.P.; Kazarian, E.M.; Karakashinian, Y.V.

    1993-01-01

    Interband absorption of light in a quantizing wire with non-parabolic dispersion law of charge carries, as well as energy spectrum and state densities are studied. The effect of Coulomb interaction between particles on the spectral curve of interband absorption is considered. Non-parabolic dispersion law of charge carries leads to an essential displacement of absorption line to ground state of one-dimensional exciton. 7 refs

  13. Lead poisoning in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Bond, E; Kubin, R

    1949-01-01

    Diagnosis was made from clinical observation and laboratory examination of nine cases. A successful treatment is described based on the similarity of the metabolism of lead and calcium, the lead being deposited in the bones where it is harmless, if it remains there. Details are given of the treatment.

  14. Leading Educational Change Wisely

    Science.gov (United States)

    Forrester, Gillian

    2011-01-01

    In this article, the author reviews Christopher Branson's book entitled "Leading Educational Change Wisely". The book provides an alternative and engaging perspective on leading educational change. Branson utilises "wisdom" as its central conceptual device to present a thought-provoking and philosophical account on how leaders are able to build a…

  15. Leading Baryon Production at HERA

    International Nuclear Information System (INIS)

    Dodonov, V.; Schmitt, S.

    2009-01-01

    The production of highly energetic forward neutrons has been studied in deep-inelastic scattering. The data were taken with the H1 detector at HERA in the years 2006-2007 and correspond to an integrated luminosity of 117 pb -1 . Semi-inclusive cross sections have been measured in the kinematic region 4 2 2 , 0.7*10 -4 -1 and the fractional momentum of the neutron 0.3 L T and compared to the predictions of models of leading neutron production. Differential cross sections for dijet photoproduction and in association with a leading neutron have been measured in the reaction e + p → e + jet jet X n with the ZEUS detector at HERA using an integrated luminosity of 40pb -1 . The data are consistent with a simple pion exchange model. The ratio of the neutron-tagged and dijet cross sections show violations of factorization of the lepton and photon vertices which can be explained by kinematic effects constraining the phase space for neutron production. Normalised double-differential leading-neutron cross sections have been measured in dijet photoproduction for the first time. The distributions can be fully characterised by only two energy dependent parameters extracted from fits to the data. Absorption effects were studied by comparing the dijet photoproduction measurements and similar results in deep inelastic scattering. No clear effect, not related to kinematics, was observed. In a resolved-enriched dijet photoproduction sample, significantly fewer neutrons were seen than for direct. This depletion can also be accounted for by kinematic constraints. The semi-inclusive reaction e + p → e + X p was studied with the ZEUS detector at HERA using an integrated luminosity of 12.8 pb -1 . The final state proton, which was detected with the ZEUS leading proton spectrometer, carried a large fraction of the incoming proton energy, x L > 0.32, and its transverse momentum squared satisfied p T 2 2 ; the exchanged photon virtuality, Q 2 , was greater than 3 GeV 2 and the range of

  16. Nonlinear Cyclotron absorption of a hole doppleron in cadmium

    Energy Technology Data Exchange (ETDEWEB)

    Voloshin, I.F.; Bugal' ter, G.A.; Demikhovskii, V.Y.; Fisher, L.M.; Yudin, V.A.

    1977-10-01

    We investigated experimentally the nonlinear behavior of the impedance of a cadmium plate in the region of existence of the hole doppleron. It is shown theoretically that this phenomenon can be attributed to nonlinear cyclotron absorption of the wave in the metal. A theory of nonlinear cyclotron absorption of a hole doppleron in cadmium is constructed. The nonlinearity is due to the influence of the wave magnetic field H that alters the trajectories of the resonant electrons responsible for the cyclotron asorption. The Lorentz force connected with the field H modulates the particle velocity along the magnetic field at a characteristic frequency ..omega../sub 0/ proportional to the square root of the wave amplitude. The modulation of the longitudinal particle velocity leads to violation of the condition of their resonant interaction with the wave, as a result of which the absorption coefficient decreases. The nonlinearity is significant when the frequency ..omega../sub 0/ is large compared with the electron-collision frequency. A decrease of the cyclotron absorption changes radically the picture of the surface-impedance oscillations of the plate in the magnetic field. We studied in the experiment the influence of the temperature, of the angle of inclination of the magnetic field, and of the frequency on the nonlinear-effect threshold field that separates the regions of linear and nonlinear behavior of the sample impedance. The measurement results are in qualitative agreement with the conclusions of the theory.

  17. Fundamental absorption edge of CdP2 single crystals

    International Nuclear Information System (INIS)

    Bondar', G.I.; Koval', V.S.; Kurik, M.V.

    1986-01-01

    Fundamental absorption edge of tetragonal CdP 2 crystals is investigated within the temperature range of 4.2-293 K. The crystals are grown by the Bridgman methods and resublimation methods and possess different degree of perfection and purity. In perfect CdP 2 crystals with small concentration of impurities in the region of K > 20 cm -1 the shape of the absorption edge spectrum is described by the Urbach rule. The Urbach rule parameters are defined. The electron-phonon interaction is shown to be the determinant at K > 20 cm -1 and the direct vertical transition is observed. A slight additional absorption with maximum at 2.163 eV within the range of K -1 and at T ≤ 50 is associated with transition from shallow acceptor level to the conduction zone. The impurity leads to the shift of the fundamental absorption edge to the long-wavelength side and diffusion of electrons on impurities is resulted

  18. Enhancement of broadband optical absorption in photovoltaic devices by band-edge effect of photonic crystals.

    Science.gov (United States)

    Tanaka, Yoshinori; Kawamoto, Yosuke; Fujita, Masayuki; Noda, Susumu

    2013-08-26

    We numerically investigate broadband optical absorption enhancement in thin, 400-nm thick microcrystalline silicon (µc-Si) photovoltaic devices by photonic crystals (PCs). We realize absorption enhancement by coupling the light from the free space to the large area resonant modes at the photonic band-edge induced by the photonic crystals. We show that multiple photonic band-edge modes can be produced by higher order modes in the vertical direction of the Si photovoltaic layer, which can enhance the absorption on multiple wavelengths. Moreover, we reveal that the photonic superlattice structure can produce more photonic band-edge modes that lead to further optical absorption. The absorption average in wavelengths of 500-1000 nm weighted to the solar spectrum (AM 1.5) increases almost twice: from 33% without photonic crystal to 58% with a 4 × 4 period superlattice photonic crystal; our result outperforms the Lambertian textured structure.

  19. Absorption of the laser radiation by the laser plasma with gas microjet targets

    Science.gov (United States)

    Borisevichus, D. A.; Zabrodskii, V. V.; Kalmykov, S. G.; Sasin, M. E.; Seisyan, R. P.

    2017-01-01

    An upper limit of absorption of the laser radiation in the plasma produced in a gas jet Xe target with the average density of (3-6) × 1018 cm-3 and the effective diameter of 0.7 mm is found. It is equal to ≈50% and remains constant under any variation in this range of densities. This result contradicts both theoretical assessments that have predicted virtually complete absorption and results of earlier experiments with the laser spark in an unlimited stationary Xe gas with the same density, where the upper limit of absorption was close to 100%. An analysis shows that nonlinearity of absorption and plasma nonequilibrium lead to the reduction of the absorption coefficient that, along with the limited size of plasma, can explain the experimental results.

  20. Airborne Laser Infrared Absorption Spectrometer (ALIAS-II) for in situ Atmospheric Measurements of N(sub 2)0, CH(sub 4), CO, HCl, and NO(sub 2) from Balloon or RPA Platforms

    Science.gov (United States)

    Scott, D.; Herman, R.; Webster, C.; May, R.; Flesch, G.; Moyer, E.

    1998-01-01

    The Airborne Laser Infrared Absorption Spectrometer II (ALIAS-II) is a lightweight, high-resolution (0.0003 cm-1), scanning, mid-infrared absorption spectrometer based on cooled (80 K) lead-salt tunable diode laser sources.

  1. Phosphorus absorption in drip irrigation

    International Nuclear Information System (INIS)

    Guennelon, R.; Habib, R.

    1979-01-01

    Introducing the use of solute phosphate with drip irrigation may be an unsatisfying practice on account of the very weak mobility of PO 4 anion. Nevertheless P can move down to 30-40 cm depth by following the saturated flux along earth-worms holes or crakes, or by displacement in very narrow structural porosity, even in heavy soils. In this case roots cannot easily absorb PO 4 from soil solution, as soon as the soil is quite saturated. On the other hand, it seems that P absorption occurs very quickly and easily when the implantation of 32 P tagged solution is carried out at the border of zone which is concerned by the irrigation effects [fr

  2. HI Absorption in Merger Remnants

    Science.gov (United States)

    Teng, Stacy H.; Veileux, Sylvain; Baker, Andrew J.

    2012-01-01

    It has been proposed that ultraluminous infrared galaxies (ULIRGs) pass through a luminous starburst phase, followed by a dust-enshrouded AGN phase, and finally evolve into optically bright "naked" quasars once they shed their gas/dust reservoirs through powerful wind events. We present the results of our recent 21- cm HI survey of 21 merger remnants with the Green Bank Telescope. These remnants were selected from the QUEST (Quasar/ULIRG Evolution Study) sample of ULIRGs and PG quasars; our targets are all bolometrically dominated by AGN and sample all phases of the proposed ULIRG -> IR-excess quasar -> optical quasar sequence. We explore whether there is an evolutionary connection between ULIRGs and quasars by looking for the occurrence of HI absorption tracing neutral gas outflows; our results will allow us to identify where along the sequence the majority of a merger's gas reservoir is expelled.

  3. Multistage quantum absorption heat pumps.

    Science.gov (United States)

    Correa, Luis A

    2014-04-01

    It is well known that heat pumps, while being all limited by the same basic thermodynamic laws, may find realization on systems as "small" and "quantum" as a three-level maser. In order to quantitatively assess how the performance of these devices scales with their size, we design generalized N-dimensional ideal heat pumps by merging N-2 elementary three-level stages. We set them to operate in the absorption chiller mode between given hot and cold baths and study their maximum achievable cooling power and the corresponding efficiency as a function of N. While the efficiency at maximum power is roughly size-independent, the power itself slightly increases with the dimension, quickly saturating to a constant. Thus, interestingly, scaling up autonomous quantum heat pumps does not render a significant enhancement beyond the optimal double-stage configuration.

  4. Sound absorption with green materials

    Science.gov (United States)

    Trematerra, Amelia; Lombardi, Ilaria

    2017-07-01

    Green materials are a valid alternative to traditional materials that are by-products of processing oil. At the end of their useful life, green materials can be disposed of without polluting the environment. They are now being used in the construction and automotive industries. While, studies are currently being carried out in the aviation sector on the use of green materials for non-structural components of airplanes. Green materials can be used to improve the acoustic comfort inside buildings as well as mitigate reverberation, echoes effects and reduce the transmission of noise between rooms. In this paper, the acoustic measurements of the properties of green materials are reported. The absorption coefficient of samples of the materials were measured in the frequency range from 200 Hz to 2,000 Hz with an impedance tube, with the flow resistance being measured.

  5. Mixture for plugging absorption zones

    Energy Technology Data Exchange (ETDEWEB)

    Sitinkov, G V; Kovalenko, N G; Makarov, L V; Zinnatulchin, Ts Kh

    1981-01-17

    A mixture is proposed for plugging absorption zones. The mixture contains synthetic polymer and a solvent. So as to increase the penetrability of the mixture through a reduction in its viscosity and an increase in insulation properties, the compound contains either Capron or Neilon as the synthetic polyamide resin polmyer, and concentrated chloride as the solvent. The mixture is prepared in a special AzINMASh-30 unit (acid cart). After the mixture has been produced, it is injected into the borehole by means of an acid cart pump. So as to prevent coaggulation at the point when the mixture in injected into the stratum through tubes, the mixture is placed betwen chemically inert fluids, for example, a clay mortar. The inert and compressed fluids are injected by means of a cementing unit. The entire process of production and application of the mixture is simple and fully automated through the use of well-known equipment.

  6. Lead-free piezoceramics.

    Science.gov (United States)

    Saito, Yasuyoshi; Takao, Hisaaki; Tani, Toshihiko; Nonoyama, Tatsuhiko; Takatori, Kazumasa; Homma, Takahiko; Nagaya, Toshiatsu; Nakamura, Masaya

    2004-11-04

    Lead has recently been expelled from many commercial applications and materials (for example, from solder, glass and pottery glaze) owing to concerns regarding its toxicity. Lead zirconium titanate (PZT) ceramics are high-performance piezoelectric materials, which are widely used in sensors, actuators and other electronic devices; they contain more than 60 weight per cent lead. Although there has been a concerted effort to develop lead-free piezoelectric ceramics, no effective alternative to PZT has yet been found. Here we report a lead-free piezoelectric ceramic with an electric-field-induced strain comparable to typical actuator-grade PZT. We achieved this through the combination of the discovery of a morphotropic phase boundary in an alkaline niobate-based perovskite solid solution, and the development of a processing route leading to highly textured polycrystals. The ceramic exhibits a piezoelectric constant d33 (the induced charge per unit force applied in the same direction) of above 300 picocoulombs per newton (pC N(-1)), and texturing the material leads to a peak d33 of 416 pC N(-1). The textured material also exhibits temperature-independent field-induced strain characteristics.

  7. Bone lead levels and lead isotope ratios in red grouse from Scottish and Yorkshire moors

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Vernon G., E-mail: vthomas@uoguelph.ca [Department of Integrative Biology, College of Biological Science, University of Guelph, Guelph, Ontario, N1G 2W1 (Canada); Scheuhammer, Anton M.; Bond, Della E. [Metals Toxicology Laboratory, National Wildlife Research Centre, Carleton University, Ottawa, Ontario, K1A 0H3 (Canada)

    2009-05-15

    Leg and foot bones of adult and juvenile red grouse (Lagopus lagopus scoticus) were collected from hunter-shot birds on two Scottish estates (Glendye and Invermark) and one Yorkshire estate in September, 2003. The lead content of bones was measured by atomic absorption spectrophotometry, and corresponding stable lead isotopes (Pb204, 206, 207, 208) by inductively coupled plasma mass spectrometry. At the Glendye (N = 111) and Invermark (N = 85) estates, relatively few birds (5.4% and 3.5%, respectively) had highly elevated bone lead concentrations (> 20 mug/g dry weight). In bones of these highly exposed birds, a combination of Pb206:Pb207 and Pb208:Pb207ratios was consistent with ingestion of lead gunshot available in Europe. By contrast, Yorkshire grouse experienced a high incidence (65.8%) of bone lead > 20 mug/g. The Pb206:Pb207 and Pb208:Pb207ratios in bones of these highly exposed birds were consistent with a combined exposure to ingested lead gunshot and lead from galena mining in the region. Lead isotope ratios also indicated that lead from UK gasoline combustion and fallout from atmospheric particles was not a likely source of elevated lead in bones of either Scottish or Yorkshire grouse. Suggested management options for the three moors include adopting nontoxic shot for all game shooting on the estates, allowing heather (Calluna vulgaris) vegetation to grow tall in lead shot fall-out zones to reduce physical access to high densities of lead shot already present, and provision of calcareous grit across moors to reduce lead assimilation from all ingested sources of lead.

  8. Bone lead levels and lead isotope ratios in red grouse from Scottish and Yorkshire moors

    International Nuclear Information System (INIS)

    Thomas, Vernon G.; Scheuhammer, Anton M.; Bond, Della E.

    2009-01-01

    Leg and foot bones of adult and juvenile red grouse (Lagopus lagopus scoticus) were collected from hunter-shot birds on two Scottish estates (Glendye and Invermark) and one Yorkshire estate in September, 2003. The lead content of bones was measured by atomic absorption spectrophotometry, and corresponding stable lead isotopes (Pb204, 206, 207, 208) by inductively coupled plasma mass spectrometry. At the Glendye (N = 111) and Invermark (N = 85) estates, relatively few birds (5.4% and 3.5%, respectively) had highly elevated bone lead concentrations (> 20 mug/g dry weight). In bones of these highly exposed birds, a combination of Pb206:Pb207 and Pb208:Pb207ratios was consistent with ingestion of lead gunshot available in Europe. By contrast, Yorkshire grouse experienced a high incidence (65.8%) of bone lead > 20 mug/g. The Pb206:Pb207 and Pb208:Pb207ratios in bones of these highly exposed birds were consistent with a combined exposure to ingested lead gunshot and lead from galena mining in the region. Lead isotope ratios also indicated that lead from UK gasoline combustion and fallout from atmospheric particles was not a likely source of elevated lead in bones of either Scottish or Yorkshire grouse. Suggested management options for the three moors include adopting nontoxic shot for all game shooting on the estates, allowing heather (Calluna vulgaris) vegetation to grow tall in lead shot fall-out zones to reduce physical access to high densities of lead shot already present, and provision of calcareous grit across moors to reduce lead assimilation from all ingested sources of lead.

  9. Lead poisoning in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, M R; Lewis, G

    1963-08-03

    Within a short period, 14 cases of lead poisoning in the dogs have been encountered. A detailed record appears justified as no published reference can be found to this condition occurring in Britain and because reports from other countries stress the similarity of the clinical manifestations of lead poisoning to those of the common infections of the dog. Five of the 14 clinical cases of lead poisoning are described. The available literature is reviewed and the diagnosis and significance of the condition discussed. 19 references, 2 tables.

  10. Parameter study of self-absorption effects in Total Reflection X-ray Fluorescence-X-ray Absorption Near Edge Structure analysis of arsenic

    International Nuclear Information System (INIS)

    Meirer, F.; Pepponi, G.; Streli, C.; Wobrauschek, P.; Kregsamer, P.; Zoeger, N.; Falkenberg, G.

    2008-01-01

    Total reflection X-ray Fluorescence (TXRF) analysis in combination with X-ray Absorption Near Edge Structure (XANES) analysis is a powerful method to perform chemical speciation studies at trace element levels. However, when measuring samples with higher concentrations and in particular standards, damping of the oscillations is observed. In this study the influence of self-absorption effects on TXRF-XANES measurements was investigated by comparing measurements with theoretical calculations. As(V) standard solutions were prepared at various concentrations and dried on flat substrates. The measurements showed a correlation between the damping of the oscillations and the As mass deposited. A Monte-Carlo simulation was developed using data of the samples shapes obtained from confocal white light microscopy. The results showed good agreement with the measurements; they confirmed that the key parameters are the density of the investigated atom in the dried residues and the shape of the residue, parameters that combined define the total mass crossed by a certain portion of the incident beam. The study presents a simple approach for an a priori evaluation of the self-absorption in TXRF X-ray absorption studies. The consequences for Extended X-ray Absorption Fine Structure (EXAFS) and XANES measurements under grazing incidence conditions are discussed, leading to the conclusion that the damping of the oscillations seems to make EXAFS of concentrated samples non feasible. For XANES 'fingerprint' analysis samples should be prepared with a deposited mass and sample shape leading to an acceptable absorption for the actual investigation

  11. Quantum quench of Kondo correlations in optical absorption.

    Science.gov (United States)

    Latta, C; Haupt, F; Hanl, M; Weichselbaum, A; Claassen, M; Wuester, W; Fallahi, P; Faelt, S; Glazman, L; von Delft, J; Türeci, H E; Imamoglu, A

    2011-06-29

    The interaction between a single confined spin and the spins of an electron reservoir leads to one of the most remarkable phenomena of many-body physics--the Kondo effect. Electronic transport measurements on single artificial atoms, or quantum dots, have made it possible to study the effect in great detail. Here we report optical measurements on a single semiconductor quantum dot tunnel-coupled to a degenerate electron gas which show that absorption of a single photon leads to an abrupt change in the system Hamiltonian and a quantum quench of Kondo correlations. By inferring the characteristic power-law exponents from the experimental absorption line shapes, we find a unique signature of the quench in the form of an Anderson orthogonality catastrophe, induced by a vanishing overlap between the initial and final many-body wavefunctions. We show that the power-law exponent that determines the degree of orthogonality can be tuned using an external magnetic field, which unequivocally demonstrates that the observed absorption line shape originates from Kondo correlations. Our experiments demonstrate that optical measurements on single artificial atoms offer new perspectives on many-body phenomena previously studied using transport spectroscopy only.

  12. Occupational exposure to lead--granulometric distribution of airborne lead in relation to risk assessment.

    Science.gov (United States)

    Carelli, G; Masci, O; Altieri, A; Castellino, N

    1999-07-01

    The amount of airborne lead absorbed by the body during occupational exposure depends not only on lead concentration in workplace air, but also on the granulometric distribution of the aerosol. The Occupational Safety and Health Administration (OSHA) set the lead Permissible Exposure Limit (PEL) at 50 micrograms/m3 on the basis of Bernard's model and a number of assumptions, including assumption "C", which predicts that the first 12.5 micrograms/m3 are made up of fine particles (aerodynamic diameter 1 micron. Occupational exposure to airborne lead at a concentration of 50 micrograms/m3 and a granulometric distribution calculated according to the above mentioned assumption, leads, in the model, to a mean blood level of 40 micrograms/dl. In the present study, we tested the validity of assumption "C" in the environmental air of a factory that manufactured crystal glassware containing 24% lead oxide. An 8-stage impactor was used to measure the particle size of airborne dust collected from personal and area samplings. Results indicate that, on the whole, assumption "C" cannot be considered valid in the work environment investigated in this study. As a result, lead absorption levels in exposed workers may be noticeably different from those predicted by the OSHA model. We therefore suggest that in order to make a correct evaluation of the risk of occupational exposure to lead, it is essential to integrate total airborne lead concentration with a measurement of the granulometric distribution of the aerosol.

  13. Adsorption of lead over graphite oxide.

    Science.gov (United States)

    Olanipekun, Opeyemi; Oyefusi, Adebola; Neelgund, Gururaj M; Oki, Aderemi

    2014-01-24

    The adsorption efficiency and kinetics of removal of lead in presence of graphite oxide (GO) was determined using the Atomic Absorption Spectrophotometer (AAS). The GO was prepared by the chemical oxidation of graphite and characterized using FTIR, SEM, TGA and XRD. The adsorption efficiency of GO for the solution containing 50, 100 and 150 ppm of Pb(2+) was found to be 98%, 91% and 71% respectively. The adsorption ability of GO was found to be higher than graphite. Therefore, the oxidation of activated carbon in removal of heavy metals may be a viable option to reduce pollution in portable water. Published by Elsevier B.V.

  14. Blood lead levels and chronic blood loss

    Energy Technology Data Exchange (ETDEWEB)

    Manci, E.A.; Cabaniss, M.L.; Boerth, R.C.; Blackburn, W.R.

    1986-03-01

    Over 90% of lead in blood is bound to the erythrocytes. This high affinity of lead for red cells may mean that chronic blood loss is a significant means for excretion of lead. This study sought correlations between blood lead levels and clinical conditions involving chronic blood loss. During May, June and July, 146 patients with normal hematocrits and red cell indices were identified from the hospital and clinic populations. For each patient, age, race, sex and medical history were noted, and a whole blood sample was analyzed by flameless atomic absorption spectrophotometry. Age-and race-matched pairs showed a significant correlation of chronic blood loss with lead levels. Patients with the longest history of blood loss (menstruating women) had the lowest level (mean 6.13 ..mu..g/dl, range 3.6-10.3 ..mu..g/dl). Post-menopausal women had levels (7.29 ..mu..g/dl, 1.2-14 ..mu..g/dl) comparable to men with peptic ulcer disease, or colon carcinoma (7.31 ..mu..g/dl, 5.3-8.6 ..mu..g/dl). The highest levels were among men who had no history of bleeding problems (12.39 ..mu..g/dl, 2.08-39.35 ..mu..g/dl). Chronic blood loss may be a major factor responsible for sexual differences in blood lead levels. Since tissue deposition of environmental pollutants is implicated in diseases, menstruation may represent a survival advantage for women.

  15. Lead in Construction

    National Research Council Canada - National Science Library

    1993-01-01

    Although Occupational Safety and Health Administration (OSHA) regulations for occupational lead exposure have been in effect since 1971 for the construction and general industries, the agency regulations for general industry in 1978...

  16. Radiation shielding lead shield

    International Nuclear Information System (INIS)

    Dei, Shoichi.

    1991-01-01

    The present invention concerns lead shields for radiation shielding. Shield boxes are disposed so as to surround a pipeline through which radioactive liquids, mists or like other objects are passed. Flanges are formed to each of the end edges of the shield boxes and the shield boxes are connected to each other by the flanges. Upon installation, empty shield boxes not charged with lead particles and iron plate shields are secured at first at the periphery of the pipeline. Then, lead particles are charged into the shield boxes. This attains a state as if lead plate corresponding to the depth of the box is disposed. Accordingly, operations for installation, dismantling and restoration can be conducted in an empty state with reduced weight to facilitate the operations. (I.S.)

  17. Phytosterol glycosides reduce cholesterol absorption in humans

    OpenAIRE

    Lin, Xiaobo; Ma, Lina; Racette, Susan B.; Anderson Spearie, Catherine L.; Ostlund, Richard E.

    2009-01-01

    Dietary phytosterols inhibit intestinal cholesterol absorption and regulate whole body cholesterol excretion and balance. However, they are biochemically heterogeneous and a portion is glycosylated in some foods with unknown effects on biological activity. We tested the hypothesis that phytosterol glycosides reduce cholesterol absorption in humans. Phytosterol glycosides were extracted and purified from soy lecithin in a novel two-step process. Cholesterol absorption was measured in a series ...

  18. Vitamin B12 absorption from eggs.

    Science.gov (United States)

    Doscherholmen, A; McMahon, J; Ripley, D

    1975-09-01

    The assimilation of 57Co B12 from in vivo labeled eggs was much inferior to that of a comparable amount of crystalline 57Co B12. Furthermore, the absorption varied with the form in which the eggs were served. Judged by the urinary excretion test and the plasma absorption of radioactivity the average absorption from boiled and fried eggs was more than twice that from scrambled whole eggs, but less than half that absorbed from crystalline 57Co B12.

  19. Flame emission, atomic absorption and fluorescence spectrometry

    International Nuclear Information System (INIS)

    Horlick, G.

    1980-01-01

    Six hundred and thirty references are cited in this review. The information in the review is divided into 12 major areas: books, reviews, and bibliographies; fundamental studies in flames; developments in instrumentation; measurement techniques and procedure; flame emission spectrometry; flame atomic absorption spectrometry; flame molecular absorption spectrometry; electrothermal atomization atomic absorption spectroscopy; hydride generation techniques; graphite furnace atomic emission spectrometry; atomic fluorescence spectrometry; and analytical comparisons

  20. Lead poisoning in mink

    Energy Technology Data Exchange (ETDEWEB)

    Purdy, J G

    1962-03-01

    This paper describes a case of lead poisoning in minks. The mink were housed in pens which had been painted with a bridge paint containing lead. They had chewed on the pen and ingested the paint. The animals that did not die were moved to new pens, and vitamin D and calcium gluconate were added to their diets. In three days, a marked improvement was seen in the food and water consumption, and convolutions became less frequent.

  1. Lead poisoning in dogs

    International Nuclear Information System (INIS)

    Zook, B.C.; Carpenter, J.L.; Leeds, E.B.

    1969-01-01

    Lead poisoning was diagnosed and studied in 60 dogs. It was found that lead poisoning is a common disease of young dogs, especially in the summer and fall, and is related to their chewing and eating habits resulting in the ingestion of paint, linoleum, or other lead-containing materials. The signs were characterized by gastrointestinal dysfunction (colic, vomiting, and diarrhea) and nervous disorders (convulsions, hysteria, nervousness, behavioral changes). The blood findings, which the authors consider nearly pathognomonic, consisted of numerous stippled and immature (especially nucleated) erythrocytes in the absence of severe anemia. Protein and casts were frequently found in the urine. Radiography sometimes revealed lead-containing particles in the gastro-intestinal tract, and lead lines were occasionally detected in the metaphysis of long bones in immature dogs. Treatment with calcium ethylenediamine-tetraacetic acid resulted in rapid and often dramatic recoveries in nearly all instances. Removal of lead from the gastrointestinal tract and treatment to relieve pronounced central nervous disorders was sometimes necessary. 40 references, 6 figures, 7 tables

  2. Emission and Absorption Entropy Generation in Semiconductors

    DEFF Research Database (Denmark)

    Reck, Kasper; Varpula, Aapo; Prunnila, Mika

    2013-01-01

    While emission and absorption entropy generation is well known in black bodies, it has not previously been studied in semiconductors, even though semiconductors are widely used for solar light absorption in modern solar cells [1]. We present an analysis of the entropy generation in semiconductor...... materials due to emission and absorption of electromagnetic radiation. It is shown that the emission and absorption entropy generation reduces the fundamental limit on the efficiency of any semiconductor solar cell even further than the Landsberg limit. The results are derived from purely thermodynamical...

  3. X-ray absorption in atomic potassium

    International Nuclear Information System (INIS)

    Gomilsek, Jana Padeznik; Kodre, Alojz; Arcon, Iztok; Nemanic, Vincenc

    2008-01-01

    A new high-temperature absorption cell for potassium vapor is described. X-ray absorption coefficient of atomic potassium is determined in the energy interval of 600 eV above the K edge where thresholds for simultaneous excitations of 1s and outer electrons, down to [1s2p] excitation, appear. The result represents also the atomic absorption background for XAFS (X-ray absorption fine structure) structure analysis. The K ionization energy in the potassium vapor is determined and compared with theoretical data and with the value for the metal

  4. Magnesium Diboride Current Leads

    Science.gov (United States)

    Panek, John

    2010-01-01

    A recently discovered superconductor, magnesium diboride (MgB2), can be used to fabricate conducting leads used in cryogenic applications. Dis covered to be superconducting in 2001, MgB2 has the advantage of remaining superconducting at higher temperatures than the previously used material, NbTi. The purpose of these leads is to provide 2 A of electricity to motors located in a 1.3 K environment. The providing environment is a relatively warm 17 K. Requirements for these leads are to survive temperature fluctuations in the 5 K and 11 K heat sinks, and not conduct excessive heat into the 1.3 K environment. Test data showed that each lead in the assembly could conduct 5 A at 4 K, which, when scaled to 17 K, still provided more than the required 2 A. The lead assembly consists of 12 steelclad MgB2 wires, a tensioned Kevlar support, a thermal heat sink interface at 4 K, and base plates. The wires are soldered to heavy copper leads at the 17 K end, and to thin copper-clad NbTi leads at the 1.3 K end. The leads were designed, fabricated, and tested at the Forschungszentrum Karlsruhe - Institut foer Technische Physik before inclusion in Goddard's XRS (X-Ray Spectrometer) instrument onboard the Astro-E2 spacecraft. A key factor is that MgB2 remains superconducting up to 30 K, which means that it does not introduce joule heating as a resistive wire would. Because the required temperature ranges are 1.3-17 K, this provides a large margin of safety. Previous designs lost superconductivity at around 8 K. The disadvantage to MgB2 is that it is a brittle ceramic, and making thin wires from it is challenging. The solution was to encase the leads in thin steel tubes for strength. Previous designs were so brittle as to risk instrument survival. MgB2 leads can be used in any cryogenic application where small currents need to be conducted at below 30 K. Because previous designs would superconduct only at up to 8 K, this new design would be ideal for the 8-30 K range.

  5. Changes in UV absorption of sunscreens after UV irradiation

    Science.gov (United States)

    Tarras-Wahlberg, N.; Stenhagen, G.; Larkö, O.; Rosén, A.; Wennberg, A.-M.; Wennerström, O.

    2000-03-01

    In the present investigation we have studied the change in the absorption spectrum of some photoactive organic species in sunscreens after UVA and UVB irradiation in a dose normally encountered during a full day in the sun. The absorbance of 2-ethylhexyl 4-methoxycinnamate was reduced significantly, while 3-(4-methylbenzyliden)camphor seemed to be rather stable. The benzophenones studied seemed to be relatively stable. In the case of 4-tert.butyl-4´-methoxy-dibenzoylmethane there was a rapid decrease in the UVA absorption leading to unsatisfactory protection in the UVA region. 4-Isopropyl-dibenzoylmethane also lost most of its UV protective capacity after irradiation with UVA. UVB seemed to have a minor effect on all the samples. The present study including gas chromatography and mass spectrometry analysis indicates that some of the photoactive organic species commonly used today in sunscreens are unstable following UV irradiation.

  6. LED-Absorption-QEPAS Sensor for Biogas Plants

    Science.gov (United States)

    Köhring, Michael; Böttger, Stefan; Willer, Ulrike; Schade, Wolfgang

    2015-01-01

    A new sensor for methane and carbon dioxide concentration measurements in biogas plants is presented. LEDs in the mid infrared spectral region are implemented as low cost light source. The combination of quartz-enhanced photoacoustic spectroscopy with an absorption path leads to a sensor setup suitable for the harsh application environment. The sensor system contains an electronics unit and the two gas sensors; it was designed to work as standalone device and was tested in a biogas plant for several weeks. Gas concentration dependent measurements show a precision better than 1% in a range between 40% and 60% target gas concentration for both sensors. Concentration dependent measurements with different background gases show a considerable decrease in cross sensitivity against the major components of biogas in direct comparison to common absorption based sensors. PMID:26007746

  7. Ultra-Short Laser Absorption In Solid Targets

    International Nuclear Information System (INIS)

    Harfouche, A.; Bendib, A.

    2008-01-01

    With the rapid development and continuously improving technology of subpicosecond laser pulse generation, new interesting physical problems are now investigated. Among them the laser light absorption in solid targets. During the interaction with solid targets, high intensity laser pulses are absorbed by electrons in optical skin depths, leading to rapid ionization before that significant ablation of solid material takes place. The ultra-short laser is absorbed in the overdense plasma through the electron-ion collisions (normal skin effect) or collisionless mechanisms (anomalous skin effect or sheath inverse bremsstrahlung). These two regimes depend on the laser intensity, the plasma temperature and the ionization state Z. In this work we solve numerically the Fokker-Planck equation to compute the electron distribution function in the skin layer. In the second step we compute the surface impedance and we deduce the absorption coefficient.

  8. LED-Absorption-QEPAS Sensor for Biogas Plants

    Directory of Open Access Journals (Sweden)

    Michael Köhring

    2015-05-01

    Full Text Available A new sensor for methane and carbon dioxide concentration measurements in biogas plants is presented. LEDs in the mid infrared spectral region are implemented as low cost light source. The combination of quartz-enhanced photoacoustic spectroscopy with an absorption path leads to a sensor setup suitable for the harsh application environment. The sensor system contains an electronics unit and the two gas sensors; it was designed to work as standalone device and was tested in a biogas plant for several weeks. Gas concentration dependent measurements show a precision better than 1% in a range between 40% and 60% target gas concentration for both sensors. Concentration dependent measurements with different background gases show a considerable decrease in cross sensitivity against the major components of biogas in direct comparison to common absorption based sensors.

  9. Binary mixtures of mercury/ selenium, and lead/selenium

    African Journals Online (AJOL)

    Physiologically-based biokinetic models have been developed for predicting simultaneously the Absorption, Distribution, Metabolism and Elimination (ADME) properties of lead (Pb) and selenium (Se), and mercury (Hg) and selenium in a number of target tissues of humans. This was done for three population groups, ...

  10. Determination of lead and cadmium in biological materials

    International Nuclear Information System (INIS)

    Stoeppler, M.; Backhaus, F.; Dahl, R.; Hagedorn-Goetz, H.; Hilpert, K.; Klahre, P.; Rutzel, H.; Valenta, P.; Nuernberg, H.W.; Dumont, M.

    1975-01-01

    Sampling techniques and experience, and decomposition methods are presented. The processes used in flameless atomic absorption spectrometry (including the method using automatic insertion of samples), pulse polarography and isotope dilution mass spectrometry are described. Finally, the results of lead and cadmium measurements in bovine liver, blood, urine and hair samples are reported and discussed with a comparison of methods in some cases

  11. Optical Studies on Sol-Gel Derived Lead Chloride Crystals

    OpenAIRE

    Rejeena, I; Lillibai, B; Nithyaja, B; Nampoori, P.N V; Radhakrishnan, P

    2013-01-01

    Optical characterization of lead chloride crystals prepared by sol-gel method is reported. The relevant sol-gel technique is used for the preparation of PbCl2 samples with five different types. In this paper, we report the absorption and fluorescence behaviour of pure, UV& IR irradiated and electric & magnetic field applied lead chloride crystal samples in solution phase at two different concentrations. Optical bandgap and emission studies of these crystals are also done.

  12. Gas cooled leads

    International Nuclear Information System (INIS)

    Shutt, R.P.; Rehak, M.L.; Hornik, K.E.

    1993-01-01

    The intent of this paper is to cover as completely as possible and in sufficient detail the topics relevant to lead design. The first part identifies the problems associated with lead design, states the mathematical formulation, and shows the results of numerical and analytical solutions. The second part presents the results of a parametric study whose object is to determine the best choice for cooling method, material, and geometry. These findings axe applied in a third part to the design of high-current leads whose end temperatures are determined from the surrounding equipment. It is found that cooling method or improved heat transfer are not critical once good heat exchange is established. The range 5 5 but extends over a large of values. Mass flow needed to prevent thermal runaway varies linearly with current above a given threshold. Below that value, the mass flow is constant with current. Transient analysis shows no evidence of hysteresis. If cooling is interrupted, the mass flow needed to restore the lead to its initially cooled state grows exponentially with the time that the lead was left without cooling

  13. Particulate absorption properties in the Red Sea from hyperspectral particulate absorption spectra

    KAUST Repository

    Tiwari, Surya Prakash; Zarokanellos, Nikolaos; Kheireddine, Malika; Shanmugam, Palanisamy; Jones, Burton

    2018-01-01

    This paper aims to describe the variability of particulate absorption properties using a unique hyperspectral dataset collected in the Red Sea as part of the TARA Oceans expedition. The absorption contributions by phytoplankton (aph) and non

  14. Lead isotopes in soils near five historic American lead smelters and refineries

    International Nuclear Information System (INIS)

    Rabinowitz, Michael B.

    2005-01-01

    This survey of soil lead in the vicinity of old industrial sites examines how the stable isotope patterns vary among the sites according to the sources of the lead ore processed at each site. Lead smelters and refineries, which closed down decades ago, are the basis of this investigation. Samples were taken from near five old factory sites in Collinsville and Alton (Illinois), Ponderay (Idaho), East Chicago (Indiana) and Omaha (Nebraska). Historical records were searched for accounts of the sources of the lead. Lead concentrations were measured by atomic absorption flame spectrophotometry, and stable isotopic analysis was done by plasma ionization mass spectrometry. At every site visited, remnants of the old factories, in terms of soil lead pollution, could be found. In spite of potential complications of varying smelter feedstock sourced from mines of different geological age, it was possible to match the isotopic patterns in the soils with the documented sources of the ores. The Collinsville and Alton sites resembled Missouri lead. The Ponderay value was higher than major Bunker Hill, Idaho deposits, but closer to the minor, nearby Oreille County, Washington ores. Mostly Utah ore was used in East Chicago. The Omaha soil reflects lead from Mexico, Colorado and Montana

  15. Lead contamination of environment in Meza Valley, Yugoslavia: some considerations on lead content in soil and plants

    Energy Technology Data Exchange (ETDEWEB)

    Djuric, D; Kerin, Z

    1970-01-01

    As part of a broad ecological study of lead contamination, soil samples and underground parts of some vegetables were analyzed for lead by the dithizone method. Vegetables fell into three groups: those with a relatively high Pb content (over 30 mg/kg); those with a medium Pb content (over 10 mg/kg); and those with a low Pb content (under 5 mg/kg). Variations in Pb content in the same kind of vegetables represented variations in soil Pb content and absorption. Variations between different kinds of vegetables were due to differences in plant physiology and capacity of absorption, shape and size of root, and depth of root in soil. Lead content was higher in vegetables grown in summer and fall than for the same vegetables grown in spring. Lead absorption coefficients were calculated for underground parts of vegetables according to the relation between the Pb content of the plant and total Pb content of soil and according to the relation between the Pb content of the plant and the AL-soluble Pb in soil (AL is the ammonium lactate acetic acid mixture). The latter method gave much less dispersed coefficients, indicating that AL-soluble Pb represents much more authoritative data for determining absorption coefficients than total soil Pb.

  16. Infrared multiphoton absorption and decomposition

    International Nuclear Information System (INIS)

    Evans, D.K.; McAlpine, R.D.

    1984-01-01

    The discovery of infrared laser induced multiphoton absorption (IRMPA) and decomposition (IRMPD) by Isenor and Richardson in 1971 generated a great deal of interest in these phenomena. This interest was increased with the discovery by Ambartzumian, Letokhov, Ryadbov and Chekalin that isotopically selective IRMPD was possible. One of the first speculations about these phenomena was that it might be possible to excite a particular mode of a molecule with the intense infrared laser beam and cause decomposition or chemical reaction by channels which do not predominate thermally, thus providing new synthetic routes for complex chemicals. The potential applications to isotope separation and novel chemistry stimulated efforts to understand the underlying physics and chemistry of these processes. At ICOMP I, in 1977 and at ICOMP II in 1980, several authors reviewed the current understandings of IRMPA and IRMPD as well as the particular aspect of isotope separation. There continues to be a great deal of effort into understanding IRMPA and IRMPD and we will briefly review some aspects of these efforts with particular emphasis on progress since ICOMP II. 31 references

  17. Leading healthcare in complexity.

    Science.gov (United States)

    Cohn, Jeffrey

    2014-12-01

    Healthcare institutions and providers are in complexity. Networks of interconnections from relationships and technology create conditions in which interdependencies and non-linear dynamics lead to surprising, unpredictable outcomes. Previous effective approaches to leadership, focusing on top-down bureaucratic methods, are no longer effective. Leading in complexity requires leaders to accept the complexity, create an adaptive space in which innovation and creativity can flourish and then integrate the successful practices that emerge into the formal organizational structure. Several methods for doing adaptive space work will be discussed. Readers will be able to contrast traditional leadership approaches with leading in complexity. They will learn new behaviours that are required of complexity leaders, along with challenges they will face, often from other leaders within the organization.

  18. 40 CFR Appendix B to Part 80 - Test Methods for Lead in Gasoline

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test Methods for Lead in Gasoline B... in Gasoline Method 1—Standard Method Test for Lead in Gasoline by Atomic Absorption Spectrometry 1. Scope. 1.1. This method covers the determination of the total lead content of gasoline. The procedure's...

  19. Spectrochemical determination of lead in wines

    Directory of Open Access Journals (Sweden)

    DRAGAN MARKOVIC

    2000-06-01

    Full Text Available The determination of lead in wines of different origin was performed by means of atomic emission spectroscopy with argon stabilized DC. U-shaped arc and electrothermal atomic absorption spectrometry. The comparison of the results obtained by the direct and standard addition method has indicated the presence of a depressive effect of the complex organic matrix. The effect is avoided successfully by mineralization, as well as by dissolution of the samples. Thus, a relative simple but precise and sensitive method involving the application of a stabilized arc and photoelectric detection with time integration of the emission signals is recommended for the determination of low concentrations of lead in wines. The complex organic matrix was investigated by recording the IR spectra of different wine fractions.

  20. A Low-Cost Quantitative Absorption Spectrophotometer

    Science.gov (United States)

    Albert, Daniel R.; Todt, Michael A.; Davis, H. Floyd

    2012-01-01

    In an effort to make absorption spectrophotometry available to high school chemistry and physics classes, we have designed an inexpensive visible light absorption spectrophotometer. The spectrophotometer was constructed using LEGO blocks, a light emitting diode, optical elements (including a lens), a slide-mounted diffraction grating, and a…

  1. Spectral interferences in atomic absorption spectrometry, (5)

    International Nuclear Information System (INIS)

    Daidoji, Hidehiro

    1979-01-01

    Spectral interferences were observed in trace element analysis of concentrated solutions by atomic absorption spectrometry. Molecular absorption and emission spectra for strontium chloride and nitrate, barium chloride and nitrate containing 12 mg/ml of metal ion in airacetylene flame were measured in the wavelength range from 200 to 700 nm. The absorption and emission spectra of SrO were centered near 364.6 nm. The absorption spectra of SrOH around 606.0, 671.0 and 682.0 nm were very strong. And, emission spectrum of BaOH in the wavelength range from 480 to 550 nm was stronger. But, the absorption of this band spectrum was very weak. In the wavelength range from 200 to 400 nm, some unknown bands of absorption were observed for strontium and barium. Absorption spectra of SrCl and BaCl were observed in the argon-hydrogen flame. Also, in the carbon tube atomizer, the absorption spectra of SrCl and BaCl were detected clearly in the wavelength range from 185 to 400 nm. (author)

  2. Process for neptunium analysis by absorption spectrophotometry

    International Nuclear Information System (INIS)

    Wagner, J.F.

    1987-01-01

    An aqueous solution of a neptunium compounds is treated by a reagent, preferentially a vanadyl sulfate oxidized by cerium IV ions, to obtain neptunium V by oxidation of neptunium IV and reduction of neptunium VI. The reagent is chosen for a negligible absorption at the wavelength used for neptunium V absorption spectrophotometry for instance 981 nm [fr

  3. Photoelectric absorption cross sections with variable abundances

    Science.gov (United States)

    Balucinska-Church, Monika; Mccammon, Dan

    1992-01-01

    Polynomial fit coefficients have been obtained for the energy dependences of the photoelectric absorption cross sections of 17 astrophysically important elements. These results allow the calculation of X-ray absorption in the energy range 0.03-10 keV in material with noncosmic abundances.

  4. Anomalous infrared absorption in granular superconductors

    International Nuclear Information System (INIS)

    Carr, G.L.; Garland, J.C.; Tanner, D.B.

    1983-01-01

    Granular superconductors are shown to have a far-infrared absorption that is larger when the samples are superconducting than when they are normal. By constrast, theoretical models for these materials predict that when the samples become superconducting, the absorption should decrease

  5. Cimetidine absorption in humans during sucralfate coadministration.

    OpenAIRE

    D'Angio, R; Mayersohn, M; Conrad, K A; Bliss, M

    1986-01-01

    Cimetidine absorption after a single 300 mg oral dose was evaluated in six normal subjects in the absence or presence of sucralfate. Sucralfate was ingested four times a day for 2 days prior to and for two additional doses on the day of cimetidine ingestion. Sucralfate coadministration had no statistically significant influence on the rate or extent of cimetidine absorption.

  6. Ultrafast THz Saturable Absorption in Semiconductors

    DEFF Research Database (Denmark)

    Turchinovich, Dmitry; Hoffmann, Matthias C.

    2011-01-01

    We demonstrate THz saturable absorption in n-doped semiconductors GaAs, GaP, and Ge in a nonlinear THz time-domain spectroscopy experiment. Saturable absorption is caused by sample conductivity modulation due to electron heating and satellite valley scattering in the field of a strong THz pulse....

  7. Unveiling the Microfoundations of Absorptive Capacity

    DEFF Research Database (Denmark)

    Distel, Andreas Philipp

    2017-01-01

    to absorptive capacity at the organizational level and that this relationship is mediated through a microlevel process. The findings reveal that knowledge workers’ cognitive process of perspective taking and their creative behavior are important microfoundations of absorptive capacity. Moreover, the results...... emphasize the critical role of key employees in explaining firm-level heterogeneity in building organizational capabilities....

  8. Oligofructose stimulates calcium absorption in adolescents

    NARCIS (Netherlands)

    Heuvel, E.G.H.M. van den; Muys, T.; Dokkum, W. van; Schaafsma, G.

    1999-01-01

    Background: In rats, nondigestible oligosaccharides stimulate calcium absorption. Recently, this effect was also found in human subjects. Objective: The objective of the study was to investigate whether consumption of 15 g oligofructose/d stimulates calcium absorption in male adolescents. Design:

  9. A transient absorption study of allophycocyanin

    Indian Academy of Sciences (India)

    Transient dynamics of allophycocyanin trimers and monomers are observed by using the pump-probe, transient absorption technique. The origin of spectral components of the transient absorption spectra is discussed in terms of both kinetics and spectroscopy. We find that the energy gap between the ground and excited ...

  10. Excitonic Effects in Methylammonium Lead Halide Perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Beard, Matthew C [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Chen, Xihan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lu, Haipeng [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Yang, Ye [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-05-01

    The exciton binding energy in methylammonium lead iodide (MAPbI3) is about 10 meV, around 1/3 of the available thermal energy (kBT ~ 26 meV) at room temperature. Thus, exciton populations are not stable at room temperature at moderate photoexcited carrier densities. However, excitonic resonances dominate the absorption onset. Furthermore, these resonances determine the transient absorbance and transient reflectance spectra. The exciton binding energy is a reflection of the Coulomb interaction energy between photoexcited electrons and holes. As such, it serves as a marker for the strength of electron/hole interactions and impacts a variety of phenomena, such as, absorption, radiative recombination, and Auger recombination. In this Perspective, we discuss the role of excitons and excitonic resonances in the optical properties of lead-halide perovskite semiconductors. Finally, we discuss how the strong light-matter interactions induce an optical stark effect splitting the doubly spin degenerate ground exciton states and are easily observed at room temperature.

  11. Absorption of controlled-release iron

    International Nuclear Information System (INIS)

    Cook, J.D.; Lipschitz, D.A.; Skikne, B.S.

    1982-01-01

    A multiple-dose double radioiron technic was used to compare absorption of iron administered as a controlled release (CR) capsule and as an elixir; both formulations contained 50 mg elemental iron as ferrous sulfate. When taken by normal subjects in the fasting state, mean absorption from the elixir and CR capsule averaged 4.92% and 4.38%, which gave a CR capsule:elixir ratio of 0.89. This difference was not significant, but when taken with meals that inhibit absorption of dietary iron by different degrees, absorption of the CR formulation was superior. CR capsule:elixir absorption ratios averaged 1.70 from a meal that is mildly inhibitory and 3.13 from a meal that causes more marked inhibition. It is concluded that CR iron formulations may offer a therapeutic advantage to patients who take oral iron with meals to avoid gastrointestinal side effects

  12. Relational Perspectives on Leading

    DEFF Research Database (Denmark)

    Relational Perspectives on Leading discusses leadership from a relational and social constructionism perspective as practiced on an everyday basis between people. The book pursues a fast growing, practice-based approach - particularly within the Anglo-Saxon parts of the world - to organization...

  13. Learn about Lead

    Science.gov (United States)

    ... Search Main menu Environmental Topics Air Bed Bugs Chemicals and Toxics Environmental Information by Location Greener Living Health Land, ... it has some beneficial uses, it can be toxic to humans and animals causing of health ... some types of industrial facilities, and past use of lead-based paint ...

  14. Leading Causes of Blindness

    Science.gov (United States)

    ... have cataracts. They are the leading cause of blindness in the world. By age 80, more than half of all people in the United States either will have a cataract or have had cataract surgery. Common symptoms are: Blurry vision Colors that seem faded Glare Not being able to ...

  15. Lead User Innovation

    DEFF Research Database (Denmark)

    Brem, Alexander; Larsen, Henry

    2015-01-01

    covers the opposite view, where a company actively searches and involves lead users, however, with limited success also. Based on both cases, we analyze how, in these emerging processes of relating, meaning is co-created in a way that narrows the shared conceptual space for imagination and collaboration...

  16. Girls Leading Outward

    Science.gov (United States)

    Hamed, Heather; Reyes, Jazmin; Moceri, Dominic C.; Morana, Laura; Elias, Maurice J.

    2011-01-01

    The authors describe a program implemented in Red Bank Middle School in New Jersey to help at-risk, minority middle school girls realize their leadership potential. The GLO (Girls Leading Outward) program was developed by the Developing Safe and Civil Schools Project at Rutgers University and is facilitated by university students. Selected middle…

  17. Leading through Conflict

    Science.gov (United States)

    Gerzon, Mark

    2006-01-01

    This article talks about leading significant learning opportunities through conflict of ideas in a school system. Catalyzing school change can turn emotional differences of opinion into learning opportunities. Leaders who want to deal effectively with these challenging, often tense situations need to be more than good managers. They need to be…

  18. Lead Time Study,

    Science.gov (United States)

    1982-05-01

    1979, the number of titanium fabrications dropped from 16 to 4, primarily because of the sponge shortage and EPA and OSHA requirements. Non-military...East - Taiwan, Korea, Singapore, Malaysia and Hong Kong. In addition, a significant amount of ceramic parts, lead frames and high technology

  19. EFFECT OF LEAD ACETATE

    African Journals Online (AJOL)

    MICROSOFT

    increase in the production of poultry meat at a reasonable cost (Alam et al., ...... 36(4): 537-541. Taggart MA, Figuerola J, Green AJ, Mateo R, Deacon C, Osborn D, ... selenium, lead and copper levels in the livers and bones of five waterfowl ...

  20. Intoxication for lead

    International Nuclear Information System (INIS)

    Velez, Ruben Dario; Tamayo, Margarita Maria

    1999-01-01

    We present a case of a hospitalized girl with bronchopneumonia, who needed mechanic ventilation. Also she had a developmental delay and Burtons border in gums. Radiological studies showed dense transverse metaphiseal bands in long bones and hyperdensity in basal ganglia. We found high serum lead levels

  1. Lead Thickness Measurements

    International Nuclear Information System (INIS)

    Rucinski, R.

    1998-01-01

    The preshower lead thickness applied to the outside of D-Zero's superconducting solenoid vacuum shell was measured at the time of application. This engineering documents those thickness measurements. The lead was ordered in sheets 0.09375-inch and 0.0625-inch thick. The tolerance on thickness was specified to be +/- 0.003-inch. The sheets all were within that thickness tolerance. The nomenclature for each sheet was designated 1T, 1B, 2T, 2B where the numeral designates it's location in the wrap and 'T' or 'B' is short for 'top' or 'bottom' half of the solenoid. Micrometer measurements were taken at six locations around the perimeter of each sheet. The width,length, and weight of each piece was then measured. Using an assumed pure lead density of 0.40974 lb/in 3 , an average sheet thickness was calculated and compared to the perimeter thickness measurements. In every case, the calculated average thickness was a few mils thinner than the perimeter measurements. The ratio was constant, 0.98. This discrepancy is likely due to the assumed pure lead density. It is not felt that the perimeter is thicker than the center regions. The data suggests that the physical thickness of the sheets is uniform to +/- 0.0015-inch.

  2. Anatomy of lead poisoning

    African Journals Online (AJOL)

    ABEOLUGBENGAS

    Results: The primary form of lead toxicity is by oxidative stress mechanisms, apoptosis and necrosis involving ... néfastes sur la reproduction à l'avenir. Résultats:La forme ... prostate cancers, abnormal sexual ..... ensure this work is a success.

  3. Scientometry Leading us Astray

    Czech Academy of Sciences Publication Activity Database

    Haindl, Michal

    2010-01-01

    Roč. 2010, č. 82 (2010), s. 8-8 ISSN 0926-4981 Institutional research plan: CEZ:AV0Z10750506 Keywords : scientometry Subject RIV: BD - Theory of Information http://ercim-news.ercim.eu/en82/european-scene/ scientometry -leading-us-astray

  4. Total contribution of airborne lead to blood lead.

    OpenAIRE

    Manton, W I

    1985-01-01

    A nine year study of blood lead concentrations and isotope ratios carried out on a married couple shows that pulmonary deposition cannot account for all the airborne lead in blood; that lead from bone may comprise 70% of blood lead; and that during pregnancy blood lead may double due to mobilisation of lead from bone.

  5. Total contribution of airborne lead to blood lead.

    Science.gov (United States)

    Manton, W I

    1985-01-01

    A nine year study of blood lead concentrations and isotope ratios carried out on a married couple shows that pulmonary deposition cannot account for all the airborne lead in blood; that lead from bone may comprise 70% of blood lead; and that during pregnancy blood lead may double due to mobilisation of lead from bone. PMID:3970881

  6. Study on heavy metal absorption capability of chlamidomonas reinhardtii in solution containing uranium and lead

    International Nuclear Information System (INIS)

    Nguyen Thuy Binh

    2003-01-01

    The mutant strain chlamydomonas reinhardtii No.4 obtained by C 5+ ion beam irradiation could be grown in simple mineral salt medium with initial pH range of 3.5-7.5 with continued illumination of 12,000 lux under aeration. The study demonstrated that the mutant strain C.reinhardtii had a good growth in mineral salt medium containing U 6+ (concentration about 0.015 mg/ml) and Pb 2+ (concentration about 65% and Pb 2+ about 60% from solution was estimated by analyzing dried cell. (NTB)

  7. Safety and Health Topics: Lead

    Science.gov (United States)

    ... ammunition, pipes, cable covering, building material, solder, radiation shielding, collapsible tubes, and fishing weights. Lead is also ... lead linings in tanks and radiation protection, leaded glass, work involving soldering, and other work involving lead ...

  8. Environmental lead exposure among preschool children in Shanghai, China: blood lead levels and risk factors.

    Directory of Open Access Journals (Sweden)

    Jia Cao

    Full Text Available OBJECTIVE: To determine blood lead levels and to identify related risk factors among children in Shanghai; to explore the lead change trend of children after industrial transformation and to provide data for policy development to control environmental lead pollution in Shanghai. METHODS: A stratified-clustered-random sampling method was used. A tungsten atomizer absorption spectrophotometer was employed to determine blood lead levels. RESULTS: The arithmetic mean, geometric mean and median of blood lead levels of 0- to 6-year-old children from Shanghai were 22.49 µg/L, 19.65 µg/L and 19.5 µg/L, including 0.26% (6/2291 with concentrations ≥100 µg/L and 2.7% (61/2291 with concentrations ≥50 µg/L. Boys' levels (23.57 µg/L were greater than those of girls (21.2 µg/L. The blood lead levels increased with age. This survey showed that the Chongming district was the highest and Yangpu district was the lowest, this result is completely opposite with the earlier survey in Shanghai. Risk factors for lead contamination included housing environment, parents' education levels, social status, hobbies, and children's nutritional status. CONCLUSIONS: The blood lead levels of children in Shanghai were lower than the earlier data of Shanghai and those of published studies in China, but higher than the blood lead levels of developed countries. The blood lead levels of urban districts are higher than the central districts with the industrial transformation. Society and the government should take an active interest in childhood lead poisoning of urban areas.

  9. Modeling microwave electromagnetic field absorption in muscle tissues

    Science.gov (United States)

    Felbacq, D.; Clerjon, S.; Damez, J. L.; Zolla, F.

    2002-07-01

    Absorption of electromagnetic energy in human tissues is an important issue with respect to the safety of low-level exposure. Simulation is a way to a better understanding of electromagnetic dosimetry. This letter presents a comparison between results obtained from a numerical simulation and experimental data of absorbed energy by a muscle. Simulation was done using a bidimensional double-scale homogenization scheme leading to the effective permittivity tensor. Experimental measurements were performed at 10 GHz on bovine muscle, 30 hours after slaughter, thanks to the open-ended rectangular waveguide method. Results show a good agreement between measurements and simulated data.

  10. Analysis of impurities in silver matrix by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Hussain, R.; Ishaque, M.; Mohammad, D.

    1999-01-01

    A procedure for the analysis of aluminium, chromium, copper, lead, mercury, nickel and zinc mainly using flame lens atomic absorption spectrophotometry has been described. The results depict that the presence of silver does not introduce any significant interference, when standards are prepared in matching silver matrix solutions. The calibration curves obey the straight-line equations passing through the origin. Thus the separation of silver matrix from the analyte solutions is not necessary. The method has successfully been applied for the analysis of silver foils, wires, battery grade silver oxides and silver nitrate samples containing analyte elements in the concentration range 2 to 40 ppm. (author)

  11. Skin toxicology of lead species evaluated by their permeability and proteomic profiles: a comparison of organic and inorganic lead.

    Science.gov (United States)

    Pan, Tai-Long; Wang, Pei-Wen; Al-Suwayeh, Saleh A; Chen, Chih-Chieh; Fang, Jia-You

    2010-08-01

    Lead compounds are known to cause cytotoxicity and genotoxicity. Lead absorption by the skin is an important route through which this metal enters the body. The purpose of this work was to evaluate the skin permeability and toxicological profiles of two lead species, lead acetate and lead nitrate. This study assessed lead-induced toxicity mechanisms by focusing on the histopathology, proteomics, cell growth, and cellular ATP. In vitro skin permeation assays showed that there was no significant difference of lead accumulation within and across the skin between the two lead species. The presence of simulated sweat reduced the skin uptake of lead. The skin deposition of lead acetate was greater than that of lead nitrate with in vivo topical application. On the other hand, lead nitrate produced greater changes in the skin's histology and proteomic profiles compared to lead acetate. Four protein spots which showed significant changes were identified and are discussed in this study. These included glucose-related protein precursor (GRP) 78, K14, alpha-actin, and Rho GDP-dissociation inhibitor 2 (RhoGDI2). These proteins are respectively associated with oxidative stress, apoptosis, wound healing, and proliferation. Lead presented a biphasic pattern on cell growth and intracellular ATP content, with a stimulating effect at low concentrations and an inhibitory effect on cell proliferation at higher concentrations. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  12. XAFS studies of nickel-doped lead telluride

    International Nuclear Information System (INIS)

    Radisavljevic, Ivana; Novakovic, Nikola; Ivanovic, Nenad; Romcevic, Nebojsa; Manasijevic, Miodrag; Mahnke, Heinz-Eberhard

    2009-01-01

    The problem of impurities and defect states in lead telluride-based semiconductors is of crucial importance for their practical applications. X-ray absorption fine structure (XAFS) techniques are capable to address some of the key issues regarding impurities position, their valent state, as well as the local structural changes of the host lattice in the immediate surrounding of the impurity atoms. In this paper we present the results of the Ni K-absorption edge XAFS studies of Ni-doped PbTe at different temperatures. Analysis of near edge and extended XAFS regions of the measured spectra provided information about exact local environment and lattice ordering around Ni atoms.

  13. Threshold nonlinear absorption in Zeeman transitions

    International Nuclear Information System (INIS)

    Narayanan, Andal; Hazra, Abheera; Sandhya, S N

    2010-01-01

    We experimentally study the absorption spectroscopy from a collection of gaseous 87 Rb atoms at room temperature irradiated with three fields. Two of these fields are in a pump-probe saturation absorption configuration. The third field co-propagates with the pump field. The three fields address Zeeman degenerate transitions between hyperfine levels 5S 1/2 , F = 1 and 5P 3/2 , F = 0, F = 1 around the D2 line. We find a sub-natural absorption resonance in the counter-propagating probe field for equal detunings of all three fields. This absorption arises in conjunction with the appearance of increased transmission due to electro-magnetically induced transparency in the co-propagating fields. The novel feature of this absorption is its onset only for the blue of 5P 3/2 , F = 0, as the laser frequency is scanned through the excited states 5P 3/2 , F = 0, F = 1 and F = 2. The absorption rapidly rises to near maximum values within a narrow band of frequency near 5P 3/2 , F = 0. Our experimental results are compared with a dressed atom model. We find the threshold absorption to be a result of coherent interaction between the dressed states of our system.

  14. Gastrointestinal absorption of Np in rats

    International Nuclear Information System (INIS)

    Wirth, R.; Volf, V.

    1985-01-01

    The effect of Np mass and the acidity of the administered Np solutions as well as the age, sex and nutritional status of the animals injected or gavaged with 239Np or 237Np were determined. The latter factor proved to be dominant for absorption of Np from the gut. Thus in fasting weanling and young adult male rats, the absorption of 239Np was sixfold higher (0.18% and 0.12%, respectively) than in fed ones (0.03% and 0.02%, respectively). Absorption by fasted adult females was 0.05% of the administered 239Np, about half of that of adult males. Raising the Np-mass gavaged to fasted female rats to 1 and 10 mg 237Np/kg resulted in an absorption of 0.23% and 0.26%, respectively. Thus, an increased absorption of Np in adult rats seems to be expected only if a large mass is ingested. No dependence of the absorption of Np on nitric acid concentration was found. The data obtained after oral administration of 238Pu and 239Np to adult rats suggest that the f1 factor recommended by the ICRP for fractional absorption of soluble Np compounds from the gut should be decreased, whereas the f1 factor for soluble Pu compounds should be raised

  15. Aerosol Angstrom Absorption Coefficient Comparisons during MILAGRO.

    Science.gov (United States)

    Marley, N. A.; Marchany-Rivera, A.; Kelley, K. L.; Mangu, A.; Gaffney, J. S.

    2007-12-01

    Measurements of aerosol absorption were obtained as part of the MAX-Mex component of the MILAGRO field campaign at site T0 (Instituto Mexicano de Petroleo in Mexico City) by using a 7-channel aethalometer (Thermo- Anderson) during the month of March, 2006. The absorption measurements obtained in the field at 370, 470, 520, 590, 660, 880, and 950 nm were used to determine the aerosol Angstrom absorption exponents by linear regression. Since, unlike other absorbing aerosol species (e.g. humic like substances, nitrated PAHs), black carbon absorption is relatively constant from the ultraviolet to the infrared with an Angstrom absorption exponent of -1 (1), a comparison of the Angstrom exponents can indicate the presence of aerosol components with an enhanced UV absorption over that expected from BC content alone. The Angstrom exponents determined from the aerosol absorption measurements obtained in the field varied from - 0.7 to - 1.3 during the study and was generally lower in the afternoon than the morning hours, indicating an increase in secondary aerosol formation and photochemically generated UV absorbing species in the afternoon. Twelve-hour integrated samples of fine atmospheric aerosols (Petroleo (IMP) and CENICA.

  16. The effect of volatility on percutaneous absorption.

    Science.gov (United States)

    Rouse, Nicole C; Maibach, Howard I

    2016-01-01

    Topically applied chemicals may volatilize, or evaporate, from skin leaving behind a chemical residue with new percutaneous absorptive capabilities. Understanding volatilization of topical medications, such as sunscreens, fragrances, insect repellants, cosmetics and other commonly applied topicals may have implications for their safety and efficacy. A systematic review of English language articles from 1979 to 2014 was performed using key search terms. Articles were evaluated to assess the relationship between volatility and percutaneous absorption. A total of 12 articles were selected and reviewed. Key findings were that absorption is enhanced when coupled with a volatile substance, occlusion prevents evaporation and increases absorption, high ventilation increases volatilization and reduces absorption, and pH of skin has an affect on a chemical's volatility. The articles also brought to light that different methods may have an affect on volatility: different body regions; in vivo vs. in vitro; human vs. Data suggest that volatility is crucial for determining safety and efficacy of cutaneous exposures and therapies. Few articles have been documented reporting evaporation in the context of percutaneous absorption, and of those published, great variability exists in methods. Further investigation of volatility is needed to properly evaluate its role in percutaneous absorption.

  17. Lead toxicity: current concerns.

    OpenAIRE

    Goyer, R A

    1993-01-01

    Over the 20-year period since the first issue of Environmental Health Perspectives was published, there has been considerable progress in the understanding of the potential toxicity of exposure to lead. Many of these advances have been reviewed in published symposia, conferences, and review papers in EHP. This brief review identifies major advances as well as a number of current concerns that present opportunities for prevention and intervention strategies. The major scientific advance has be...

  18. CMS lead tungstate crystals

    CERN Multimedia

    Laurent Guiraud

    2000-01-01

    These crystals are made from lead tungstate, a crystal that is as clear as glass yet with nearly four times the density. They have been produced in Russia to be used as scintillators in the electromagnetic calorimeter on the CMS experiment, part of the LHC project at CERN. When an electron, positron or photon passes through the calorimeter it will cause a cascade of particles that will then be absorbed by these scintillating crystals, allowing the particle's energy to be measured.

  19. Leading change: 3--implementation.

    Science.gov (United States)

    Kerridge, Joanna

    The potential for all staff to contribute to service improvement, irrespective of discipline, role or function, is outlined in the 2011 NHS leadership framework. This advocates developing the skills of the entire workforce to create a climate of continuous service improvement. As nurses are often required to take the lead in managing change in clinical practice, this final article in a three-part series focuses on implementing ande potentia reviewing change.

  20. The effect of psychological stress on iron absorption in rats

    Directory of Open Access Journals (Sweden)

    Zhao Min

    2009-11-01

    Full Text Available Abstract Background Psychological stress (PS is recognized as an important pathogenic factor which leads to metabolism disorder in many diseases. Previous studies have shown that systemic iron homeostasis in mammalians was changed under specific stress conditions. Methods In present study, we used communication box to create psychological stress model and investigated the iron apparent absorption, iron accumulation in the apical poles of villous enterocytes and protein expressions of ferroportin 1 (FPN1, ferritin, divalent metal transporter 1 (DMT1. Results Our study showed that iron apparent absorption decreased and iron significantly accumulated in the apical poles of villous enterocytes in 3 d and 7 d PS groups. The expression of intestinal FPN1 in 3 d and 7 d PS groups was lower than that of control, while the change of intestinal ferritin was opposite. However, the expression of DMT1 did not change. Conclusion These results demonstrate that PS can decrease iron absorption in rats, which might be related to regulation expression of iron transporters.