WorldWideScience

Sample records for low-to-moderate lead absorption

  1. [Study on lead absorption in pumpkin by atomic absorption spectrophotometry].

    Science.gov (United States)

    Li, Zhen-Xia; Sun, Yong-Dong; Chen, Bi-Hua; Li, Xin-Zheng

    2008-07-01

    A study was carried out on the characteristic of lead absorption in pumpkin via atomic absorption spectrophotometer. The results showed that lead absorption amount in pumpkin increased with time, but the absorption rate decreased with time; And the lead absorption amount reached the peak in pH 7. Lead and cadmium have similar characteristic of absorption in pumpkin.

  2. Gas absorption and discharge behaviors of lead-lithium

    International Nuclear Information System (INIS)

    Sakabe, Toshiro; Yokomine, Takehiko; Kunugi, Tomoaki; Kawara, Zensaku; Ueki, Yoshitaka; Tanaka, Teruya

    2014-01-01

    Highlights: • The absorption of argon in the lead-lithium is comparable with that of helium even at the solid state. • For the molten state of lead-lithium, the absorption of argon could be larger than that of helium. • It is observed that the argon tends to desorb when the phase change of lead-lithium occurs. • It is observed from the TPD-MS analysis that the argon tends to desorb when the phase change of lead-lithium occurs. - Abstract: The absorption of rare gas in the lead-lithium has been quite low and the gas is used as a cover-gas to control the environment of experiment. In our previous thermo-fluid experiment by using lithium-lead, it was found the cover gas pressure enclosed in the very leak tight container of lithium-lead was decreased with time, that is, the gas-absorption of the solid lithium-lead occurred at room temperature under atmospheric pressure. The variation of pressure exceeded the retention of argon in lead-lithium which is expected by the published data. Therefore, we aim to confirm those phenomena under well-controlled experimental condition by using argon, nitrogen and helium. According to the results of gas exposure tests, the absorption of argon in the lead-lithium is comparable with that of helium even at the solid state. For the molten state of lead-lithium, the absorption of argon could be larger than that of helium. It is also observed from the TPD-MS analysis that the argon tends to desorb when the phase change of lead-lithium occurs. If the retention of argon in the lead-lithium cannot be ignored, the problem of Ar-41 activity should be taken into consideration as well as the problem of argon bubble in the lead-lithium

  3. Low to moderate temperature nanolaminate heater

    Science.gov (United States)

    Eckels, J Del [Livermore, CA; Nunes, Peter J [Danville, CA; Simpson, Randall L [Livermore, CA; Hau-Riege, Stefan [Fremont, CA; Walton, Chris [Oakland, CA; Carter, J Chance [Livermore, CA; Reynolds, John G [San Ramon, CA

    2011-01-11

    A low to moderate temperature heat source comprising a high temperature energy source modified to output low to moderate temperatures wherein the high temperature energy source modified to output low to moderate temperatures is positioned between two thin pieces to form a close contact sheath. In one embodiment the high temperature energy source modified to output low to moderate temperatures is a nanolaminate multilayer foil of reactive materials that produces a heating level of less than 200.degree. C.

  4. Telomere length in children environmentally exposed to low-to-moderate levels of lead

    International Nuclear Information System (INIS)

    Pawlas, Natalia; Płachetka, Anna; Kozłowska, Agnieszka; Broberg, Karin; Kasperczyk, Sławomir

    2015-01-01

    Shorter relative telomere length in peripheral blood is a risk marker for some types of cancers and cardiovascular diseases. Several environmental hazards appear to shorten telomeres, and this shortening may predispose individuals to disease. The aim of the present cross-sectional study was to assess the effect of environmental exposure to lead on relative telomere length (rTL) in children. A cohort of 99 8-year-old children was enrolled from 2007–2010. Blood lead concentrations (B-Pb) were measured by graphite furnace atomic absorption spectrometry, and blood rTL was measured by quantitative PCR. The geometric mean of B-Pb was 3.28 μg/dl (range: 0.90–14.2), and the geometric mean of rTL was 1.08 (range: 0.49–2.09). B-Pb was significantly inversely associated with rTL in the children (r S = − 0.25, p = 0.013; in further analyses both log-transformed-univariate regression analysis β = − 0.13, p = 0.026, and R 2 adj 4%; and β = − 0.12, p = 0.056 when adjusting for mothers' smoking during pregnancy, Apgar score, mother's and father's ages at delivery, sex and mother's education, R 2 adj 12%, p = 0.011). The effect of lead remained significant in children without prenatal tobacco exposure (N = 87, r S = − 0.24, p = 0.024; in further analyses, β = − 0.13, p = 0.029, and R 2 adj 4%). rTL was not affected by sex, the concentrations of other elements in the blood (i.e., cadmium and selenium concentrations), or oxidative injury parameters (total antioxidant status, 8-hydroxydeoxyguanosine and thiobarbituric acid-reactive substances). Lead exposure in childhood appears to be associated with shorter telomeres, which might contribute to diseases, such as cardiovascular disease. The inverse association between blood lead level and the telomeres in children emphasizes the importance of further reducing lead levels in the environment. - Highlights: • This cross-sectional study analyzes the association between environmental lead exposure

  5. Telomere length in children environmentally exposed to low-to-moderate levels of lead

    Energy Technology Data Exchange (ETDEWEB)

    Pawlas, Natalia, E-mail: n-pawlas@wp.pl [Institute of Occupational Medicine and Environmental Health, PL 41-200 Sosnowiec (Poland); Płachetka, Anna [Department of Animal Physiology and Ecotoxicology, University of Silesia, Bankowa str. 9, 40-007 Katowice (Poland); Kozłowska, Agnieszka [Institute of Occupational Medicine and Environmental Health, PL 41-200 Sosnowiec (Poland); Broberg, Karin [Institute of Environmental Medicine, Unit of Metals & Health, Box 210, SE-171 77 Stockholm (Sweden); Kasperczyk, Sławomir [Department of Biochemistry, Medical University of Silesia, Katowice, SMDZ in Zabrze, 41-808 Zabrze (Poland)

    2015-09-01

    Shorter relative telomere length in peripheral blood is a risk marker for some types of cancers and cardiovascular diseases. Several environmental hazards appear to shorten telomeres, and this shortening may predispose individuals to disease. The aim of the present cross-sectional study was to assess the effect of environmental exposure to lead on relative telomere length (rTL) in children. A cohort of 99 8-year-old children was enrolled from 2007–2010. Blood lead concentrations (B-Pb) were measured by graphite furnace atomic absorption spectrometry, and blood rTL was measured by quantitative PCR. The geometric mean of B-Pb was 3.28 μg/dl (range: 0.90–14.2), and the geometric mean of rTL was 1.08 (range: 0.49–2.09). B-Pb was significantly inversely associated with rTL in the children (r{sub S} = − 0.25, p = 0.013; in further analyses both log-transformed-univariate regression analysis β = − 0.13, p = 0.026, and R{sup 2}adj 4%; and β = − 0.12, p = 0.056 when adjusting for mothers' smoking during pregnancy, Apgar score, mother's and father's ages at delivery, sex and mother's education, R{sup 2}adj 12%, p = 0.011). The effect of lead remained significant in children without prenatal tobacco exposure (N = 87, r{sub S} = − 0.24, p = 0.024; in further analyses, β = − 0.13, p = 0.029, and R{sup 2}adj 4%). rTL was not affected by sex, the concentrations of other elements in the blood (i.e., cadmium and selenium concentrations), or oxidative injury parameters (total antioxidant status, 8-hydroxydeoxyguanosine and thiobarbituric acid-reactive substances). Lead exposure in childhood appears to be associated with shorter telomeres, which might contribute to diseases, such as cardiovascular disease. The inverse association between blood lead level and the telomeres in children emphasizes the importance of further reducing lead levels in the environment. - Highlights: • This cross-sectional study analyzes the association between

  6. Correlation between some parameters of lead absorption and lead intoxication

    Science.gov (United States)

    Waldron, H. A.

    1971-01-01

    Waldron, H. A. (1971).Brit. J. industr. Med.,28, 195-199. Correlation between some parameters of lead absorption and lead intoxication. Use has been made of data collected over a number of years from workers exposed to a lead hazard in a motor-car factory. The correlations between various parameters of lead absorption and lead intoxication were computed, including blood and urine lead concentrations, urinary coproporphyrin, ALA and PBG concentrations, and haemoglobin concentration. In all, 15 correlation coefficients were calculated, of which only six showed a statistically significant result (i.e., Plead and urine lead (r = 0·38, Plead and coproporphyrin (r = 0·42, Plead and ALA (r = 0·43, Plead and PBG (r = 0·19, P<0·05). PMID:5572689

  7. Neutron absorption profile in a reactor moderated by different mixtures of light and heavy waters

    International Nuclear Information System (INIS)

    Nagy, Mohamed E.; Aly, Mohamed N.; Gaber, Fatma A.; Dorrah, Mahmoud E.

    2014-01-01

    Highlights: • We studied neutron absorption spectra in a mixed water moderated reactor. • Changing D 2 O% in moderator induced neutron energy spectral shift. • Most of the neutrons absorbed in control rods were epithermal. • Control rods worth changes were not proportional to changes of D 2 O% in moderator. • Control rod arrangement influenced the neutronic behavior of the reactor. - Abstract: A Monte-Carlo parametric study was carried out to investigate the neutron absorption profile in a model of LR-0 reactor when it is moderated by different mixtures of heavy/light waters at molecular ratios ranging from 0% up to 100% D 2 O at increments of 10% in D 2 O. The tallies included; neutron absorption profiles in control rods and moderator, and neutron capture profile in 238 U. The work focused on neutron absorption in control rods entailing; total mass of control rods needed to attain criticality, neutron absorption density and total neutron absorption in control rods at each of the studied mixed water moderators. The aim was to explore whether thermal neutron poisons are the most suitable poisons to be used in control rods of nuclear reactors moderated by mixed heavy/light water moderators

  8. Low-density moderation in the storage of PWR fuel assemblies

    International Nuclear Information System (INIS)

    Alcorn, F.M.

    1987-01-01

    The nuclear criticality safety of PWR fuel storage arrays requires that the potential of low-density moderation within the array be considered. The calculated criticality effect of low-density moderation in a typical PWR fuel assembly array is described in this paper. Calculated reactivity due to low-density moderation can vary significantly between physics codes that have been validated for well moderated systems. The availability of appropriate benchmark experiments for low-density moderation is quite limited; attempts to validate against the one set of suitable experiments at low density have been disappointing. Calculations indicate that a typical array may be unacceptable should the array be subjected to interstitial moderation equivalent to 5 % of full density water. Array parameters (such as spacing and size) will dramatically affect the calculated maximum K-eff at low-density moderation. Administrative and engineered control may be necessary to assure maintenance of safety at low-density moderation. Potential sources for low-density moderation are discussed; in general, accidentally achieving degrees of low-density moderation which might lead to a compromise of safety are not credible. (author)

  9. Iron, lead, and cobalt absorption: similarities and dissimilarities

    International Nuclear Information System (INIS)

    Barton, J.C.; Conrad, M.E.; Holland, R.

    1981-01-01

    Using isolated intestinal segments in rats, the absorption of iron, lead, and cobalt was increased in iron deficiency and decreased in iron loading. Similarly, the absorption of these metals was decreased in transfusional erythocytosis, after intravenous iron injection and after parenteral endotoxin injection. Acute bleeding or abbreviated intervals of dietary iron deprivation resulted in increased iron absorption from isolated intestinal segments and in intact animals, while the absorption of lead and cobalt was unaffected. These results suggest that the specificity of the mucosal metal absorptive mechanism is either selectively enhanced for iron absorption by phlebotomy or brief periods of dietary iron deprivation, or that two or more mucosal pathways for iron absorption may exist

  10. Factors affecting the absorption and excretion of lead in the rat

    International Nuclear Information System (INIS)

    Conrad, M.E.; Barton, J.C.

    1978-01-01

    A reliable method for studying lead absorption and excretion in rats is described. Lead absorption occurs primarily in the duodenum where lead enters the epithelial mucosal cells. There is a relative mucosal block for lead with increasing intraluminal doses. Certain substances which bind lead and increase its solubility enhance its absorption. Iron, zinc, and calcium decrease the absorption of lead without affecting its solubility, probably by competing for shared absorptive receptors in the intestinal mucosa. The total body burden of lead does not affect lead absorption. Thus, lead does not have a feedback mechanism which limits absorption. Lead absorption is increased during rapid periods of growth and in iron-deficient animals. It is diminished with starvation and in iron-overloaded animals. The excretion and kinetics of tracer doses of radiolead were quantified. Erythrocytes seem to serve an important role in transport. Excretion occurs in urine and stool. Bile is an important route of excretion in the gut. Although most of a tracer dose is rapidly excreted, the excretory process is limited permitting lead accumulation primarily in bone

  11. Low dimensional neutron moderators for enhanced source brightness

    DEFF Research Database (Denmark)

    Mezei, Ferenc; Zanini, Luca; Takibayev, Alan

    2014-01-01

    In a recent numerical optimization study we have found that liquid para-hydrogen coupled cold neutron moderators deliver 3–5 times higher cold neutron brightness at a spallation neutron source if they take the form of a flat, quasi 2-dimensional disc, in contrast to the conventional more voluminous...... for cold neutrons. This model leads to the conclusions that the optimal shape for high brightness para-hydrogen neutron moderators is the quasi 1-dimensional tube and these low dimensional moderators can also deliver much enhanced cold neutron brightness in fission reactor neutron sources, compared...... to the much more voluminous liquid D2 or H2 moderators currently used. Neutronic simulation calculations confirm both of these theoretical conclusions....

  12. Influence of dietary minerals and fat on the absorption of lead. [Rats

    Energy Technology Data Exchange (ETDEWEB)

    Barltrop, D.; Khoo, H.E.

    1976-01-01

    The nutritional factors influencing the absorption of lead from the gut were studied using both intact animals and ligated gut loop preparation. Short-term feeding studies were made in groups of six rats using diets of constant lead content (0.075%) but in which the nutritional components were varied sequentially. Dietary lead was labelled with /sup 203/Pb. Absorption was determined in the carcass and individual organs by means of a small-animal whole-body counter. The results showed that absorption was enhanced to twenty-times control value by diets deficient in minerals and seven-fold by diets of high fat content. Conversely, high mineral diets were shown to result in a two-fold reduction in lead absorption. The interaction of lead with individual dietary components was further studied under controlled conditions using ligated gut loop preparations. Using this technique the relative roles of luminal interaction and tissue response for lead absorption were explored and the kinetics of lead absorption determined.

  13. Variations in Hematologic Responses to Increased Lead Absorption in Young Children

    Science.gov (United States)

    Chisolm, J. Julian; Mellits, E. David; Keil, Julian E.; Barrett, Maureen B.

    1974-01-01

    In the study of human populations, much emphasis is placed on the concentration of lead in whole peripheral blood. There is a considerable body of evidence which indicates that this measurement reflects recent and current assimilation of lead. While broad ranges in blood lead concentration have been associated with differing risks of toxicity for groups, it is not a precise index of adverse effect per se, even at elevated levels. Within the red blood cell itself there is not a close association between the concentration of lead and such adverse metabolic effects as the increased loss of potassium caused by lead. Above the apparent “threshold zone” of approximately 30–50 μg Pb/100 ml whole blood, equivalent metabolic effects on heme synthesis may be seen over an interval of at least 20 μg Pb/100 ml whole blood. This variation will be examined with particular reference to the interrelationship between the concentrations of lead and protoporphyrin in peripheral blood. The data indicate that limitations in both precision and accuracy of measurement account for a relatively small fraction of the observed variations. Together with other experimental and clinical information, they suggest that concurrent dietary deficiency of iron may be one of the important modifying factors in the responses of subjects with increased lead absorption. It is suggested that suspected adverse effects upon the various organ systems associated with increased lead absorption be measured directly and that the CaEDTA mobilization test for lead should be more fully explored as a measure of the “metabolically active” fraction of the total body lead burden. PMID:4831151

  14. Determination of Lung-to-Blood Absorption Rates for Lead and Bismuth which are Appropriate for Radon Progeny

    International Nuclear Information System (INIS)

    Marsh, J.W.; Birchall, A.

    1999-01-01

    The ICRP Publication 66 Human Respiratory Tract Model (HRTM) treats clearance as a competitive process between absorption into blood and particle transport to the gastrointestinal tract and lymphatics. The ICRP recommends default absorption rates for lead and bismuth in ICRP Publication 71 but states that the values are not appropriate for short-lived radon progeny. This paper describes an evaluation of published data from volunteer experiments to estimate the absorption half-times of lead and bismuth that are appropriate for short-lived radon progeny. The absorption half-time for lead was determined to be 10±2 h, based on 212 Pb lung and blood retention data from several studies. The absorption half-time for bismuth was estimated to be about 13 h, based on 212 Bi urinary excretion data from one experiment and the ICRP biokinetic model for bismuth as a decay product of lead. (author)

  15. Does lead use the intestinal absorptive pathways of iron? Impact of iron status on murine 210Pb and 59Fe absorption in duodenum and ileum in vivo

    International Nuclear Information System (INIS)

    Elsenhans, Bernd; Janser, Heinz; Windisch, Wilhelm; Schuemann, Klaus

    2011-01-01

    Highlights: → Absorption of 210 Pb increases much less than that of 59 Fe in murine duodena. → 210 Pb-absorption is almost equally high in murine duodenal and ileal segments. → 59 Fe absorption is much lower in ileal than in duodenal segments. → There must be an additional DMT1-independet pathway for intestinal Pb absorption. -- Abstract: Background: Human isotope studies and epidemiological trials are controversial as to whether lead absorption shares the absorptive pathways of iron and whether body lead content can be reduced by iron supplementation. Aim: To compare the impact of iron-deficiency on 59 Fe- and 210 Pb-absorption rates in duodenal and ileal segments. Methods: 59 Fe- and 210 Pb-absorption was determined in ligated duodenal and ileal segments from juvenile and adult iron-deficient and iron-adequate C57Bl6 wild-type mice (n = 6) in vivo at luminal concentrations corresponding to human exposure (Fe: 1 and 100 μmol/L; Pb: 1 μmol/L). Results and discussion: 59 Fe-absorption increased 10-15-fold in iron-deficient duodena from adult and adolescent mice. Ileal 59 Fe-absorption was 4-6 times lower than in iron-adequate duodena showing no adaptation to iron-deficiency. This in accordance to expectation as the divalent metal transport 1 (DMT1) shows low ileal expression levels. Juvenile 59 Fe-absorption was about twice as high as in adult mice. In contrast, duodenal 210 Pb-absorption was increased only 1.5-1.8-fold in iron-deficiency in juvenile and adult mice and, again in contrast to 59 Fe, ileal 210 Pb-absorption was as high as in iron-adequate duodena. Conclusions: The findings suggest a DMT1-independent pathway to mediate lead absorption along the entire small intestine in addition to DMT1-mediated duodenal uptake. Ileal lead absorption appears substantial, due the much longer residence of ingesta in the distal small intestine. Differences in lead-solubility and -binding to luminal ligands can, thus, explain the conflicting findings regarding the

  16. Narrow CIV lambda 1549A Absorption Lines in Moderate-Redshift Quasars

    DEFF Research Database (Denmark)

    Vestergaard, Marianne

    2002-01-01

    A large, high-quality spectral data base of well-selected, moderate-redshift radio-loud and radio-quiet quasars is used to characterize the incidence of narrow associated CIV lambda 1549 absorption, and how this may depend on some quasar properties, including radio-type. Preliminary results...

  17. HUD Low and Moderate Income Areas

    Data.gov (United States)

    Department of Housing and Urban Development — This dataset and map service provides information on the U.S. Housing and Urban Development's (HUD) low to moderate income areas. The term Low to Moderate Income,...

  18. Comparison of two methods for blood lead analysis in cattle: graphite-furnace atomic absorption spectrometry and LeadCare(R) II system.

    Science.gov (United States)

    Bischoff, Karyn; Gaskill, Cynthia; Erb, Hollis N; Ebel, Joseph G; Hillebrandt, Joseph

    2010-09-01

    The current study compared the LeadCare(R) II test kit system with graphite-furnace atomic absorption spectrometry for blood lead (Pb) analysis in 56 cattle accidentally exposed to Pb in the field. Blood Pb concentrations were determined by LeadCare II within 4 hr of collection and after 72 hr of refrigeration. Blood Pb concentrations were determined by atomic absorption spectrometry, and samples that were coagulated (n = 12) were homogenized before analysis. There was strong rank correlation (R(2) = 0.96) between atomic absorption and LeadCare II (within 4 hr of collection), and a conversion formula was determined for values within the observed range (3-91 mcg/dl, although few had values >40 mcg/dl). Median and mean blood pb concentrations for atomic absorption were 7.7 and 15.9 mcg/dl, respectively; for LeadCare II, medians were 5.2 mcg/dl at 4 hr and 4.9 mcg/dl at 72 hr, and means were 12.4 and 11.7, respectively. LeadCare II results at 4 hr strongly correlated with 72 hr results (R(2) = 0.96), but results at 72 hr were lower (P atomic absorption. Although there have been several articles that compared LeadCare with other analytical techniques, all were for the original system, not LeadCare II. The present study indicated that LeadCare II results correlated well with atomic absorption over a wide range of blood Pb concentrations and that refrigerating samples for up to 72 hr before LeadCare II analysis was acceptable for clinical purposes.

  19. The effect of expatriate knowledge transfer on subsidiaries’ performance: a moderating role of absorptive capacity

    Science.gov (United States)

    Arsawan, I. W. E.; Sanjaya, I. B.; Putra, I. K. M.; Sukarta, I. W.

    2018-01-01

    This study aims to examine the relationship between motivation and knowledge transfer to the subsidiaries performance and test the role of absorptive capacity as a moderating variable. The research uses quantitative design through questionnaires distribution with 5 Likert scales. The population frame is five-star hotel in Bali province, Indonesia which amounted to 63 units, the sample of research using proportional random sampling is 54 units and determined the distribution of questionnaires to 162 subsidiaries as the unit of analysis. The research model was built using the structural equation model and analyzed with smart pls- 3 software. The findings of the study revealed that subsidiaries motivation a significant effect on knowledge transfer, knowledge transfer a significant effect on subsidiaries performance, motivation a significant effect on subsidiaries performance and absorptive capacity moderated the relationship between knowledge transfer and subsidiaries performance. These findings suggest that subsidiaries and process of knowledge transfer through absorptive capacity play an important role, and that they have some impact on the subsidiaries performance.

  20. Low to moderate alcohol intake during pregnancy and risk of psychomotor deficits

    DEFF Research Database (Denmark)

    Bay, Bjørn; Støvring, Henrik; Wimberley, Theresa

    2012-01-01

    Background: To examine the effects of low to moderate alcohol consumption during pregnancy on child motor function at age 5. Methods: A prospective follow-up study of 685 women and their children sampled from the Danish National Birth Cohort based on maternal alcohol consumption during pregnancy...... reporting low to moderate levels of average alcohol consumption during pregnancy and children of mothers who abstained. Conclusions: In this study, we found no systematic association between low to moderate maternal alcohol intake during pregnancy and child motor function at age 5....

  1. Determination of Lead in Urine by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramé, Kim

    1968-01-01

    A method for the determination of lead in urine by means of atomic absorption spectrophotometry (AAS) is described. A combination of wet ashing and extraction with ammonium pyrrolidine dithiocarbamate into isobutylmethylketone was used. The sensitivity was about 0·02 μg./ml. for 1% absorption, and the detection limit was about 0·02 μg./ml. with an instrumental setting convenient for routine analyses of urines. Using the scale expansion technique, the detection limit was below 0·01 μg./ml., but it was found easier to determine urinary lead concentrations below 0·05 μg./ml. by concentrating the lead in the organic solvent by increasing the volume of urine or decreasing that of the solvent. The method was applied to fresh urines, stored urines, and to urines, obtained during treatment with chelating agents, of patients with lead poisoning. Urines with added inorganic lead were not used. The results agreed well with those obtained with a colorimetric dithizone extraction method (r = 0·989). The AAS method is somewhat more simple and allows the determination of smaller lead concentrations. PMID:5647975

  2. Clinical Perspective on Antihypertensive Drug Treatment in Adults With Grade 1 Hypertension and Low-to-Moderate Cardiovascular Risk

    DEFF Research Database (Denmark)

    Morales Salinas, Alberto; Coca, Antonio; Olsen, Michael H.

    2017-01-01

    Hypertension is a leading risk factor for disease burden globally. An unresolved question is whether grade 1 hypertension (140-159/90-99. mm. Hg) with low (cardiovascular mortality <1% at 10 years) to moderate (cardiovascular mortality ≥1% and <5% at 10 years) absolute total cardiovascular risk (...

  3. Effect of low blood lead levels on anaemia indicators and creatinine clearance rate of workers occupationally exposed to lead

    International Nuclear Information System (INIS)

    Memon, F.; Vasandani, A.G.M.

    2009-01-01

    Although recognized and written about centuries, lead toxicity remains an occupational and public health problem of global dimensions. Several studies have demonstrated that clinical and sub clinical effects of lead toxicity at the blood lead levels considered as safe, i.e., below 30 mug/dl in adults and 10 mu g/dl in children. Such studies have received scant attention in the case of lead occupational workers due to the presumption of high blood lead levels in accordance with occupation. In the present study, therefore an attempt was made to investigate the effect of low blood lead levels on indicators of anaemia and renal impairment. A cohort of 690 subjects who had been occupationally exposed to lead was studied using stratified random sampling design. The markers of anaemia included changes in Haematocrit value, Haemoglobin and Erythrocyte count where as renal health was judged from changes in creatinine clearance rate. The controls were derived from similar socioeconomic background and matched in age and sex with subjects. Blood lead levels were determined by graphite furnace atomic absorption and biochemical determinations carried out using standard procedures. Blood lead levels in the range 10-40 mu g/dl had significant effect on anaemia indicators and resulted in inverse co relationship. (Pearson's correlation coefficient r-0.65, -0.71 and -0.58 respectively for haematocrit, erythrocyte count and haemoglobin). The creatinine clearance rate estimated after adjustment for body mass index and age factors was found to depend on blood lead level and duration of exposure of subjects. These effects were statistically significant in the subjects having age in the range 15-30 years. Low lead levels in blood have high potential of inducing lead related anaemia by disturbing the pathway of heme synthesis at either ferrochetalase stage or inhibiting the amino levulinate dehydratase activity. Though creatinine clearance rate did not prove as reliable marker of renal

  4. Moderate levels of activation lead to forgetting in the think/no-think paradigm.

    Science.gov (United States)

    Detre, Greg J; Natarajan, Annamalai; Gershman, Samuel J; Norman, Kenneth A

    2013-10-01

    Using the think/no-think paradigm (Anderson & Green, 2001), researchers have found that suppressing retrieval of a memory (in the presence of a strong retrieval cue) can make it harder to retrieve that memory on a subsequent test. This effect has been replicated numerous times, but the size of the effect is highly variable. Also, it is unclear from a neural mechanistic standpoint why preventing recall of a memory now should impair your ability to recall that memory later. Here, we address both of these puzzles using the idea, derived from computational modeling and studies of synaptic plasticity, that the function relating memory activation to learning is U-shaped, such that moderate levels of memory activation lead to weakening of the memory and higher levels of activation lead to strengthening. According to this view, forgetting effects in the think/no-think paradigm occur when the suppressed item activates moderately during the suppression attempt, leading to weakening; the effect is variable because sometimes the suppressed item activates strongly (leading to strengthening) and sometimes it does not activate at all (in which case no learning takes place). To test this hypothesis, we ran a think/no-think experiment where participants learned word-picture pairs; we used pattern classifiers, applied to fMRI data, to measure how strongly the picture associates were activating when participants were trying not to retrieve these associates, and we used a novel Bayesian curve-fitting procedure to relate this covert neural measure of retrieval to performance on a later memory test. In keeping with our hypothesis, the curve-fitting procedure revealed a nonmonotonic relationship between memory activation (as measured by the classifier) and subsequent memory, whereby moderate levels of activation of the to-be-suppressed item led to diminished performance on the final memory test, and higher levels of activation led to enhanced performance on the final test. Copyright

  5. Application of extraction-chromatographic concentration to atomic absorption determination of lead and cadmium in drinking and sea water

    International Nuclear Information System (INIS)

    Bol'shova, T.A.; Agapkina, G.I.; Ershova, N.I.; Narankho, K.E.

    1988-01-01

    To increase the detection limits for lead and cadmium atomic-absorption determination in natural waters methods of extraction-chromatographic concentration of these metals using tri-n-octylamine (TOA) on polytetrafluoroethylene (PTFE) is developed. Chromatograpy was carried out from 1.5-2.0 M HBr solutions. For cadmium and lead elution acetic acid was used. It is shown that extraction-chromatographic concentration permits to decrease limits of metal atomic-absorption detection by 10 3 with the 500 ml volume sample analysis

  6. Airborne concentrations of toxic metals resulting from the use of low melting point lead alloys to construct radiotherapy shielding

    International Nuclear Information System (INIS)

    McCullough, E.C.; Senjem, D.H.

    1981-01-01

    Determinations of airborne concentrations of lead, cadmium, bismuth, and tin were made above vessels containing a fusible lead alloy (158 0 F melting point) commonly used for construction of radiotherapy blocks. Fume concentrations were determined by collection on a membrane filter and analysis by atomic absorption spectrophotometry. Samples were obtained for alloy temperatures of 200 0 , 400 0 , and 600 0 F. In all instances, concentrations were much lower than the applicable occupational limits for continuous exposure. The results of this study indicate that the use of a vented hood as a means of reducing air concentrations of toxic metals above and near vessels containing low temperature melting point lead allows commonly used in construction of radiotherapy shields appears unjustifiable. However, proper handling procedures should be observed to avoid entry into the body via alternate pathways (e.g., ingestion or skin absorption). Transmission data of a non-cadmium containing lead alloy with a melting point of 203 0 F was ascertained and is reported on

  7. Lead transfer in maternal milk, and the absorption, retention, distribution and excretion of lead in suckling mice

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Charles Arthur [Univ. of Rochester, NY (United States). Dept. of Radiation Biology and Biophysics

    1980-01-01

    Suckling mice were found to absorb and retain a greater fraction of an oral lead dose than did adult mice. Pinocytotic activity and lead uptake (in vivo) were found to be greatest in the distal small intestinal tissue. Cortisone pretreatment results in precocious cessation of pinocytotic activity in the intestine of suckling mice. Cortisone pretreatment of adult mice had no effect on whole body lead retention or intestinal tissue content of lead following an oral dose. The data indicate that the distal small intestine is the site of active pinocytosis of lead, and that pinocytosis is the major mechanism involved in lead absorption in suckling mice. Developmental differences were also observed in the percentage of lead retained in the whole body. Both groups exhibited dose-independent lead retention, indicating a first-order absorption process for each age group. Lead distribution and elimination from organs also differed between suckling and adult mice. Developmental differences were observed in organ lead concentration for kidneys and brain following oral doses. Relative distribution of lead to the brains of suckling mice were greater than to adult brains. Whole body and bone lead elimination rates were reduced in suckling compared to adult mice. Brain lead elimination rates did not differ in suckling and adult mice. A lactating mouse model was developed to study lead transfer to suckling offspring. Lead was transferred in milk to suckling offspring from mothers which had previously ingested lead in the drinking water. Relative lead transfer to suckled offspring during lactation greatly exceeded transfer to fetuses during gestation. Lactation resulted in an increased rate of maternal lead elimination. Lead concentration in milk exceeded plasma concentration by a factor of approximately 25. (ERB)

  8. Rapidity evolution of gluon TMD from low to moderate x

    International Nuclear Information System (INIS)

    Balitsky, I.

    2016-01-01

    I discuss how the rapidity evolution of gluon transverse momentum dependent distribution (TMD) changes from nonlinear evolution at small x << 1 to linear evolution at moderate x ∼ 1. I have described the rapidity evolution of gluon TMD in the whole range of Bjorken x B and the whole range of transverse momentum. It should be emphasized that with our definition of rapidity cutoff the leading-order matrix elements of TMD operators are UV-finite so the rapidity evolution is the only evolution and it describes all the dynamics of gluon TMDs in the leading-log approximation

  9. Method and apparatus for determination of temperature, neutron absorption cross section and neutron moderating power

    Science.gov (United States)

    Vagelatos, Nicholas; Steinman, Donald K.; John, Joseph; Young, Jack C.

    1981-01-01

    A nuclear method and apparatus determines the temperature of a medium by injecting fast neutrons into the medium and detecting returning slow neutrons in three first energy ranges by producing three respective detection signals. The detection signals are combined to produce three derived indicia each systematically related to the population of slow neutrons returning from the medium in a respective one of three second energy ranges, specifically exclusively epithermal neutrons, exclusively substantially all thermal neutrons and exclusively a portion of the thermal neutron spectrum. The derived indicia are compared with calibration indicia similarly systematically related to the population of slow neutrons in the same three second energy ranges returning from similarly irradiated calibration media for which the relationships temperature, neutron absorption cross section and neutron moderating power to such calibration indicia are known. The comparison indicates the temperature at which the calibration indicia correspond to the derived indicia and consequently the temperature of the medium. The neutron absorption cross section and moderating power of the medium can be identified at the same time.

  10. Lead determination in uranium mineralization soils by atomic absorption spectrometry with graphite oven

    International Nuclear Information System (INIS)

    Teixeira, Gleber Tacio

    2001-01-01

    The contamination of soils by lead has a great environmental importance due to its toxicity to vegetables, animals and humans. In general, the mobility of the lead is small due to its low solubility and strong adsorption in the soil. However, its solubility can be altered by several conditions (pH, redox potential and ionic stronger). Consequently, lead can migrate through the soil and can contaminate superficial and underground waters. The objective of this work was to determine the concentration of total lead in soil samples with uranium mineralization, in an area at Ipora/GO, having been evaluated as economically insuitable the extraction of that mineral. The radiogenic lead appears as a product of natural radioactive elements decay. In the decay series of uranium-238 we found the isotope lead-214 (half-life of 26,8 min), lead-210 (half-life of 22,3 min), and lead-206 that is stable. The sampling was done in profiles around north, south, east and west directions, starting from a reference point (FT), chosen by presenting the largest radiation of that place (4800 cps). A mass of 1 Kg of superficial soil was collected to each 20 m, in each profile, until 150 m of FT. Approximately, 1 g of dry soil, fraction 2 mm, was digested with a mixture of acids HNO 3 /HClO 4 2:1 (v/v), and the resulting solution was analyzed by atomic absorption. An atomic absorption spectrometer was used with graphite furnace, with deuterium arc to background correction and pyrolytic coated tube. Phosphoric acid was used as chemical modifier. The obtained results, using the standard additions method, presented a decrease of the lead concentration, in all profiles, when the distance of FT was increased. It was also made a radiometric screening in each sampling point. The lead concentration variate from 115,1 μg.g -1 in FT, to less than 40 μg.g -1 at 150 m of distance of FT ( 3 ) 2 was used. The method was applied to a certified sample, showing a good agreement between certified and

  11. The moderating role of absorptive capacity and the differential effects of acquisitions and alliances on Big Pharma firms' innovation performance.

    Science.gov (United States)

    Fernald, K D S; Pennings, H P G; van den Bosch, J F; Commandeur, H R; Claassen, E

    2017-01-01

    In the context of increased pharmaceutical innovation deficits and Big Pharma blockbusters' patent expirations, this paper examines the moderating role of firms' absorptive capacity in external innovation activities of Big Pharma firms. The study indicates a rising interest of Big Pharma in acquisitions of and alliances with biotechnology companies. Unfortunately, this increased interest is not reflected in the number of new drugs generated by Big Pharma. We find that acquisitions of biotech companies have negatively affected Big Pharma firms' innovation performance on average but these acquisitions might have a positive effect at higher levels of acquiring firms' absorptive capacity. Moreover, also acquisitions of pharma companies and alliances with biotech companies only have a positive effect on innovation performance at sufficiently high levels of absorptive capacity. The moderating role of absorptive capacity implicates that a tight integration of internal R&D efforts and (unrelated) external knowledge is crucial for harnessing complementarity effects.

  12. Determination of mercury, lead and cadmium in water by the CRA-atomic absorption spectrophotometry with solvent extraction

    International Nuclear Information System (INIS)

    Shim, Y.B.; Won, M.S.; Kim, C.J.

    1980-01-01

    The method of CRA-atomic absorption spectrophotometer with solvent extraction for the determination of mercury, lead and cadmium in water was studied. The optimum extracting conditions for CRA-atomic absorption spectrophotometry were the following: the complexes of mercury, lead and cadmium with dithizone were separated from the aqueous solution and concentrated into the 10 ml chloroform solution. Back extraction was performed; the concentrated mercury, lead and cadmium was extracted from the chloroform solution into the 10 ml 6-normal aqueous hydrochloric acid solution. In this case, recovery ratios were the following: mercury was 94.7%, lead 97.7% and cadmium 103.6%. The optimum operating conditions for the determination of mercury, lead and cadmium by the CRA-atomic absorption spectrophotometry also were investigated to test the dry step, ash step and atomization step for each metal. The experimental results of standard addition method were the following: the determination limit of each metal within 6% relative deviation was that lead was 0.04 ppb, and cadmium 0.01 ppb. Especially, mercury has been known impossible to determine by CRA-atomic absorption spectrophotometry until now. But in this study, mercury can be determined with CRA-atomic absorption spectrophotometer. Its determination limit was 4 ppb within 8% relative deviation. (author)

  13. Determination of Lead in Blood by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramér, Kim

    1968-01-01

    Lead in blood was determined by atomic absorption spectrophotometry, using a wet ashing procedure and a procedure in which the proteins were precipitated with trichloroacetic acid. In both methods the lead was extracted into isobutylmethylketone before measurement, using ammonium pyrrolidine dithiocarbamate as chelator. The simpler precipitation procedure was shown to give results identical with those obtained with the ashing technique. In addition, blood specimens were examined by the precipitation method and by spectral analysis, which method includes wet ashing of the samples, with good agreement. All analyses were done on blood samples from `normal' persons or from lead-exposed workers, and no additions of inorganic lead were made. The relatively simple protein precipitation technique gave accurate results and is suitable for the large-scale control of lead-exposed workers. PMID:5663425

  14. Lead isotope ratios in lichen samples evaluated by ICP-ToF-MS to assess possible atmospheric pollution sources in Havana, Cuba.

    Science.gov (United States)

    Alvarez, Alfredo Montero; Estévez Alvarez, Juan R; do Nascimento, Clístenes Williams Araújo; González, Iván Pupo; Rizo, Oscar Díaz; Carzola, Lázaro Lima; Torres, Roberto Ayllón; Pascual, Jorge Gómez

    2017-01-01

    Epiphytic lichens, collected from 119 sampling sites grown over "Roistonea Royal Palm" trees, were used to assess the spatial distribution pattern of lead (Pb) and identify possible pollution sources in Havana (Cuba). Lead concentrations in lichens and topsoils were determined by flame atomic absorption spectrophotometry and inductively coupled plasma (ICP) atomic emission spectrometry, respectively, while Pb in crude oils and gasoline samples were measured by ICP-time of flight mass spectrometry (ICP-ToF-MS). Lead isotopic ratios measurements for lichens, soils, and crude oils were obtained by ICP-ToF-MS. We found that enrichment factors (EF) reflected a moderate contamination for 71% of the samples (EF > 10). The 206 Pb/ 207 Pb ratio values for lichens ranged from 1.17 to 1.20 and were a mixture of natural radiogenic and industrial activities (e.g., crude oils and fire plants). The low concentration of Pb found in gasoline (leaded gasoline is no longer used in Cuba.

  15. An Empirical Study on Entrepreneurial Orientation, Absorptive Capacity, and SMEs’ Innovation Performance: A Sustainable Perspective

    Directory of Open Access Journals (Sweden)

    Yu-Ming Zhai

    2018-01-01

    Full Text Available Using a survey of 324 small and medium-sized enterprises (SMEs of the Yangtze River Delta in China, this study discusses the relationship between entrepreneurial orientation, absorptive capacity, environmental dynamism, and corporate technological innovation performance. The results based on a moderated moderation model show that the relationship between entrepreneurial orientation and innovation performance is significantly positive. The absorptive capacity can positively moderate this relationship. When the external environment is in high dynamism, the moderating effect of absorptive capacity will be stronger than when the environment is in low dynamism.

  16. Low-frequency radio absorption in Cassiopeia A

    Science.gov (United States)

    Arias, M.; Vink, J.; de Gasperin, F.; Salas, P.; Oonk, J. B. R.; van Weeren, R. J.; van Amesfoort, A. S.; Anderson, J.; Beck, R.; Bell, M. E.; Bentum, M. J.; Best, P.; Blaauw, R.; Breitling, F.; Broderick, J. W.; Brouw, W. N.; Brüggen, M.; Butcher, H. R.; Ciardi, B.; de Geus, E.; Deller, A.; van Dijk, P. C. G.; Duscha, S.; Eislöffel, J.; Garrett, M. A.; Grießmeier, J. M.; Gunst, A. W.; van Haarlem, M. P.; Heald, G.; Hessels, J.; Hörandel, J.; Holties, H. A.; van der Horst, A. J.; Iacobelli, M.; Juette, E.; Krankowski, A.; van Leeuwen, J.; Mann, G.; McKay-Bukowski, D.; McKean, J. P.; Mulder, H.; Nelles, A.; Orru, E.; Paas, H.; Pandey-Pommier, M.; Pandey, V. N.; Pekal, R.; Pizzo, R.; Polatidis, A. G.; Reich, W.; Röttgering, H. J. A.; Rothkaehl, H.; Schwarz, D. J.; Smirnov, O.; Soida, M.; Steinmetz, M.; Tagger, M.; Thoudam, S.; Toribio, M. C.; Vocks, C.; van der Wiel, M. H. D.; Wijers, R. A. M. J.; Wucknitz, O.; Zarka, P.; Zucca, P.

    2018-05-01

    Context. Cassiopeia A is one of the best-studied supernova remnants. Its bright radio and X-ray emission is due to shocked ejecta. Cas A is rather unique in that the unshocked ejecta can also be studied: through emission in the infrared, the radio-active decay of 44Ti, and the low-frequency free-free absorption caused by cold ionised gas, which is the topic of this paper. Aims: Free-free absorption processes are affected by the mass, geometry, temperature, and ionisation conditions in the absorbing gas. Observations at the lowest radio frequencies can constrain a combination of these properties. Methods: We used Low Frequency Array (LOFAR) Low Band Antenna observations at 30-77 MHz and Very Large Array (VLA) L-band observations at 1-2 GHz to fit for internal absorption as parametrised by the emission measure. We simultaneously fit multiple UV-matched images with a common resolution of 17″ (this corresponds to 0.25 pc for a source at the distance of Cas A). The ample frequency coverage allows us separate the relative contributions from the absorbing gas, the unabsorbed front of the shell, and the absorbed back of the shell to the emission spectrum. We explored the effects that a temperature lower than the 100-500 K proposed from infrared observations and a high degree of clumping can have on the derived physical properties of the unshocked material, such as its mass and density. We also compiled integrated radio flux density measurements, fit for the absorption processes that occur in the radio band, and considered their effect on the secular decline of the source. Results: We find a mass in the unshocked ejecta of M = 2.95 ± 0.48 M⊙ for an assumed gas temperatureof T = 100 K. This estimate is reduced for colder gas temperatures and, most significantly, if the ejecta are clumped. We measure the reverse shock to have a radius of 114″± 6″ and be centred at 23:23:26, +58:48:54 (J2000). We also find that a decrease in the amount of mass in the unshocked ejecta

  17. Radiogenic Lead with Dominant Content of 208Pb: New Coolant and Neutron Moderator for Innovative Nuclear Facilities

    Directory of Open Access Journals (Sweden)

    A. N. Shmelev

    2011-01-01

    Full Text Available As a rule materials of small atomic weight (light and heavy water, graphite, and so on are used as neutron moderators and reflectors. A new very heavy atomic weight moderator is proposed—radiogenic lead consisting mainly of isotope 208Pb. It is characterized by extremely low neutron radiative capture cross-section (0.23 mbarn for thermal neutrons, i.e., less than that for graphite and deuterium and highest albedo of thermal neutrons. It is evaluated that the use of radiogenic lead makes it possible to slow down the chain fission reaction on prompt neutrons in a fast reactor. This can increase safety of the fast reactors and reduce as well requirements pertaining to the fuel fabrication technology. Radiogenic lead with high 208Pb content as a liquid-metal coolant of fast reactors helps to achieve a favorable (negative reactivity coefficient on coolant temperature. It is noteworthy that radiogenic lead with high 208Pb content may be extracted from thorium (as well as thorium-uranium ores without isotope separation. This has been confirmed experimentally by the investigations performed at San Paulo University, Brazil.

  18. Influence of 2,3-dimercaptosuccinic acid on gastrointestinal lead absorption and whole-body lead retention

    International Nuclear Information System (INIS)

    Kapoor, S.C.; Wielopolski, L.; Graziano, J.H.; LoIacono, N.J.

    1989-01-01

    2,3-Dimercaptosuccinic acid (DMSA) is a new orally active heavy metal chelator for the treatment of childhood Pb intoxication on an outpatient basis. The influence of DMSA, as well as other chelating agents, on gastrointestinal 203Pb absorption and whole-body 203 Pb retention was examined. Groups of Sprague-Dawley rats (230-260 g) were gavaged with a solution containing approximately 25 mg/kg Pb [as Pb(NO 3 )2] plus 15 microCi 203 Pb. Some groups were then immediately given 0.11 mmol/kg of either DMSA, CaNa2EDTA, D-penicillamine, or BAL by oral gavage, while other groups received the same drugs by ip injection. Control groups received solutions of the drug vehicles po or ip. Whole-body Pb retention and gastrointestinal Pb absorption (whole body retention + urinary Pb excretion) were significantly decreased in rats that received DMSA po. This finding implies that the use of DMSA to treat childhood lead intoxication on an outpatient basis is not associated with a risk for increased Pb absorption

  19. Determination of lead in water by electrothermal atomic absorption spectrometry with a nickel(II)-ammonium tartrate modifier

    International Nuclear Information System (INIS)

    Sekerka, I.; Lechner, J.F.

    1991-01-01

    A method is described for the determination of low concentrations of lead in water samples. Atomic absorption spectrometry is used with a tungsten ribbon furnace and Zeeman background correction. Interferences are eliminated by the addition of ammonium tartrate and nickel(II) nitrate to the samples to act as a matrix modifier and adjust the pH. The results show the superior performance of this modifier over other types used conventionally. The detection limit is 1 μg l -1 relative standard deviation of -1 can be obtained. The instrumentation is simple and the method is efficient for the determination of lead in various water samples. 25 refs.; 7 figs.; 6 tabs

  20. A low-cost vaporization-atomization system for atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Bruhn F, C.G.; Ambiado V, F.; Woerner V, R.

    1990-01-01

    A low-cost vaporization-atomization system for atomic absorption spectrometry is developed as an alternative to the use of a graphite furnace in electrothermal atomic absorption spectrometry. (Author)

  1. Zinc absorption in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Valberg, L.S.; Flanagan, P.R.; Kertesz, A.; Bondy, D.C.

    1986-01-01

    Zinc absorption was measured in 29 patients with inflammatory bowel disease and a wide spectrum of disease activity to determine its relationship to disease activity, general nutritional state, and zinc status. Patients with severe disease requiring either supplementary oral or parenteral nutrition were excluded. The mean 65ZnCl2 absorption, in the patients, determined using a 65Zn and 51Cr stool-counting test, 45 +/- 17% (SD), was significantly lower than the values, 54 +/- 16%, in 30 healthy controls, P less than 0.05. Low 65ZnCl2 absorption was related to undernutrition, but not to disease activity in the absence of undernutrition or to zinc status estimated by leukocyte zinc measurements. Mean plasma zinc or leukocyte zinc concentrations in patients did not differ significantly from controls, and only two patients with moderate disease had leukocyte zinc values below the 5th percentile of normal. In another group of nine patients with inflammatory bowel disease of mild-to-moderate severity and minimal nutritional impairment, 65Zn absorption from an extrinsically labeled turkey test meal was 31 +/- 10% compared to 33 +/- 7% in 17 healthy controls, P greater than 0.1. Thus, impairment in 65ZnCl2 absorption in the patients selected for this study was only evident in undernourished persons with moderate or severe disease activity, but biochemical evidence of zinc deficiency was uncommon, and clinical features of zinc depletion were not encountered

  2. PG 1700 + 518 - a low-redshift, broad absorption line QSO

    International Nuclear Information System (INIS)

    Pettini, M.; Boksenberg, A.

    1985-01-01

    The first high-resolution optical spectra and lower resolution UV spectra of PG 1700 + 518, the only known broad-absorption-line (BAL) QSO at low emission redshift (0.288) are presented. The optical data were obtained with the Isaac Newton Telescope on the island of La Palma and the UV data with the International Ultraviolet Explorer satellite. The outstanding feature of the optical spectrum is a strong, broad Mg II absorption trough, detached from the Mg II emission line and indicative of ejection velocities of between 7000 and 18,000 km/s. Also detected were narrow (FWHM = 350 km/s) Mg II absorption lines at absolute z = 0.2698, which are probably related to the mass ejection phenomenon. It is concluded that the emission-line spectrum is similar to that of other low-redshift QSOs although there are some obvious differences from typical BAL QSOs, most notably in the unusually low level of ionization of both emission-line and broad absorption line gas. 21 references

  3. Correction to the Beer-Lambert-Bouguer law for optical absorption.

    Science.gov (United States)

    Abitan, Haim; Bohr, Henrik; Buchhave, Preben

    2008-10-10

    The Beer-Lambert-Bouguer absorption law, known as Beer's law for absorption in an optical medium, is precise only at power densities lower than a few kW. At higher power densities this law fails because it neglects the processes of stimulated emission and spontaneous emission. In previous models that considered those processes, an analytical expression for the absorption law could not be obtained. We show here that by utilizing the Lambert W-function, the two-level energy rate equation model is solved analytically, and this leads into a general absorption law that is exact because it accounts for absorption as well as stimulated and spontaneous emission. The general absorption law reduces to Beer's law at low power densities. A criterion for its application is given along with experimental examples. (c) 2008 Optical Society of America

  4. Low-reflective wire-grid polarizers with absorptive interference overlayers

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Motofumi [Department of Micro Engineering, Kyoto University, Kyoto 606-8501 (Japan); Takada, Akio; Yamada, Takatoshi; Hayasaka, Takashi; Sasaki, Kouji; Takahashi, Eiji; Kumagai, Seiji, E-mail: m-snki@me.kyoto-u.ac.jp [Devices Technology Department, Devices Division, Sony Chemical and Information Device Corporation, 3-4-1 Sakuragi, Tagajyo, Miyagi 985-0842 (Japan)

    2010-04-30

    Wire-grid (WG) polarizers with low reflectivity for visible light have been successfully developed. We theoretically consider the optical properties of simple sandwich structures of absorptive layer/transparent layer (gap layer)/high-reflective mirrors and found that it is possible to develop an antireflection (AR) coating owing to the interference along with the absorption in the absorptive layer. A wide variety of materials can be used for AR coatings by tuning the thicknesses of both the absorptive and the gap layers. This AR concept has been applied to reduce the reflectance of WG polarizers of Al. FeSi{sub 2} as an absorptive layer has been deposited by the glancing angle deposition technique immediately on the top of Al wires covered with a thin SiO{sub 2} layer as a gap layer. For the optimum combination of the thicknesses of FeSi{sub 2} and SiO{sub 2}, the reflectance becomes lower than a few per cent, independent of the polarization, whereas the transmission polarization properties remain good. Because low-reflective (LR) WG polarizers are completely composed of inorganic materials, they are useful for applications requiring high-temperature durability such as liquid crystal projection displays.

  5. Sound absorption of low-temperature reusable surface insulation candidate materials

    Science.gov (United States)

    Johnston, J. D.

    1974-01-01

    Sound absorption data from tests of four candidate low-temperature reusable surface insulation materials are presented. Limitations on the use of the data are discussed, conclusions concerning the effective absorption of the materials are drawn, and the relative significance to Vibration and Acoustic Test Facility test planning of the absorption of each material is assessed.

  6. Simultaneous Atomic Absorption Spectrometry for Cadmium and Lead Determination in Wastewater: A Laboratory Exercise

    Science.gov (United States)

    Correia, Paulo R. M.; Oliveira, Pedro V.

    2004-01-01

    The simultaneous determination of cadmium and lead by multi-element atomic absorption spectrometry with electrochemical atomization is proposed by employing a problem-based approach. The reports indicate that the students assimilated the principles of the simultaneous atomic absorption spectrometry (SIMAAS), the role of the chemical modifier, the…

  7. Rooftop Solar Technical Potential for Low-to-Moderate Income Households in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Sigrin, Benjamin O [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Mooney, Meghan E [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-04-17

    This report presents a first-of-kind assessment of the technical potential of rooftop solar for low and moderate-income households, as well as providing insight on the distribution of solar potential by tenure, income, and other building characteristics. We find that a substantial fraction of the national rooftop solar potential is located on LMI buildings and, for all incomes, a substantial fraction on multi-family and renter-occupied buildings. We also find that rooftop solar can significantly contribute to long-term penetration targets established by the U.S. DOE, though to do so requires deployment on multi-family and renter-occupied buildings. Traditional deployment models have insufficiently enabled access to solar for these income groups and building types. Without innovation either in regulatory, market, or policy factors, a large fraction of the U.S. potential is unlikely to be addressed, as well as leading to inequalities in solar access. Ironically, potential electric bill savings from rooftop solar would have the greatest material impact on the lives of low-income households as compared to their high-income counterparts.

  8. The low-ion QSO absorption-line systems

    International Nuclear Information System (INIS)

    Lanzetta, K.M.

    1988-01-01

    Various techniques are used to investigate the class of QSO absorption-line systems that exhibit low-ion absorption lines. Four separate investigations are conducted as follows: Spectroscopy of 32 QSOs at red wavelengths is presented and used to investigate intermediate-redshift MgII absorption. A total of 22 Mg II doublets are detected, from which properties of the Mg II absorbers are derived. Marginal evidence for intrinsic evolution of the number density of the Mg II absorbers with redshift is found. The data are combined with previous observations of C IV and C II seen in the same QSOs at blue wavelengths, and the properties of Mg II- and C IV-selected systems are compared. A sample is constructed of 129 QSOs for which are available published data suitable for detecting absorption-line systems that are optically thick to Lyman continuum radiation. A total of 53 such Lyman-limit systems are found, from which properties of the Lyman-limit systems are derived. It is found that the rate of incidence of the systems does not strongly evolved with redshift. This result is contrasted with the evolution found previously for systems selected on the basis of Mg II absorption. Spectroscopy at red wavelengths of eight QSOs with known damped Lyα absorption systems is presented. Spectroscopic and spectrophotometric observations aimed at detecting molecular hydrogen and dust in the z = 2.796 damped Lyα absorber toward Q1337 + 113 are presented

  9. Determination of lead in mother's milk by atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Bandarchian, F.; Assadian, F

    2002-01-01

    With due attention to increasing air pollution specially the lead amount that is generated from gasoline burning in automobiles, it seems that it is necessary to control the amount of it continuously. Because Pb has an easy absorbability to body and also damages the nervous system. For this reason determination of it in mother's milk has a special importance. In this research, the milks of 15 mothers twice a day were examined and the concentration of Pb were determined by atomic absorption spectroscopy. In accordance the international organization, the permissible amount in body is 0.05 ppm. Fortunately, the obtained data was less than of it and it showed the absorbance of lead by babies is insignificant

  10. Experimental lead poisoning in chickens

    Energy Technology Data Exchange (ETDEWEB)

    Silven, L.

    1967-01-01

    Poisoning of water fowl due to the intake of lead shot is not rare in the USA. In order to study this kind of poisoning more closely domestic fowl were given varying amounts of lead shot and lead powder. This treatment did not provoke any symptoms of poisoning. Chemical analyses of different organs, muscles, skeleton and eggs yielded low lead values. It is concluded that the low toxicity of lead administered as lead shot to the domestic fowl is due to a low absorption rate from the gastro-intestinal tract.

  11. Determination of lead in whole blood: Comparison of the LeadCare blood lead testing system with zeeman longitudinal electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pineau, A.; Viallefont, A.; Fauconneau, B.; Rafael, M.; Guillard, O.

    2002-01-01

    This study compares the efficiency of blood lead level analysis by graphite furnace atomic absorption spectrometry (GFAAS) and the portable LeadCare Blood lead testing system (LCS). Recoveries of two added lead concentrations of 22 and 42 μg/dL ranged from 102.4 to 105.5% for LCS and from 96.3 to 97.2% for GFAAS. Measurement of a certified sample (Certified Danish Whole Blood) at a blood lead concentration of 26.2 μg/dL gave within- and between-run coefficients of variation which were both approximately 8% by LCS and 2% by GFAAS. Comparison of the tested method (LCS) versus GFAAS from analysis of 76 samples of blood lead collected from workers in different industrial sectors showed imperfect overall correlation (r = 0.95). The LCS is quite suitable for screening purposes, but requires the use of non-frozen blood collected less than 24 h before. Conservative threshold values should be applied when using the LCS for initial screening in the field. (orig.)

  12. Spectrum interpretation problems with well-type Ge(Li) detectors due to self-absorption variations

    International Nuclear Information System (INIS)

    Bruin, M. de; Korthoven, P.J.M.; Bode, P.

    1979-01-01

    For use in instrumental neutron activation analysis, a well-type Ge(Li) detector compares favourably with a comparable detector without well. It combines a good energy resolution with a relatively high detector efficiency. Moreover, this efficiency is almost independent of sample dimensions. But the use of a well-type Ge(Li) detector also has been some drawbacks, as large summation effects will result from the high detector efficiency. The least severe aspect of this summation is the additional formation of many extra sum peaks in gamma-ray spectra of nuclides with moderate or highly complex decay schemes. This leads to higher computation times, but in general, the accuracy of the analysis will not be affected. A far more important aspect of the summation is found in the fact that the intensity ratios between high energy peaks and the sum peaks of self-absorption effects, which in a flat detector is limited to only the low energy part of the spectrum, may be extended to the high energy region. This leads to sample-dependent distortion of the high energy part of the gamma-ray spectrum which may result in misinterpretation of instrumental neutron activation analysis data. The only solution to this problem seems to be to prevent the relevant low energy photons from reaching the detector. This can be accomplished by using a high Z absorber inside the detector well. (Auth.)

  13. The true absorption of 131I, and its transfer to milk in cows given different stable iodine diets

    International Nuclear Information System (INIS)

    Vandecasteele, C.M.; Van Hees, M.; Hardeman, F.; Voigt, G.; Howard, B.J.

    2000-01-01

    The influence of the stable iodine content in the diet on the absorption of radioiodine and its transfer to cow's milk was investigated for cows at different stages of lactation. Three different rates of stable iodine: a low intake rate of 4 mg d -1 , a moderate intake of 35 mg d -1 and a high rate of 75 mg d -1 were fed to two groups of three lactating cows in mid- and late-lactation. The transfer to milk of a single oral administration of radioiodine was measured for the three different intake rates. The lactation phase had no significant effect on iodine transfer to milk; therefore, the data from the two lactation groups were pooled for further statistical analyses. The mean transfer coefficient values for oral radioiodine to milk increased from 0.020 d l -1 for the low treatment to 0.024 d l -1 for the moderate stable iodine rate. There was a statistically significant decrease in the transfer to milk for the high stable dietary iodine intake rate (mean transfer coefficient=0.018 d l -1 ) compared with the moderate treatment. These differences were not due to effects on absorption since true absorption was complete for all three stable iodine treatments, but rather to differential affinities and saturation levels of the thyroid and milk pathways competing for the available iodine. The same behaviour and comparable values of transfer coefficients (range 0.015-0.020 d l -1 ) were observed for stable iodine

  14. UV laser long-path absorption spectroscopy

    Science.gov (United States)

    Dorn, Hans-Peter; Brauers, Theo; Neuroth, Rudolf

    1994-01-01

    Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive

  15. Determination of lead and cadmium in urine by electrothermal atomization atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Vasil'eva, L.A.; Grinshtejn, I.L.; Gucher, Sh.; Izgi, B.

    2008-01-01

    The applicability of a DETATA sorbent to the preconcentration of lead and cadmium followed by the determination of these elements in urine using atomic absorption spectrometry with electrothermal atomization was demonstrated. After preconcentration by a factor of 10, the limits of detection were 0.01 and 0.2 μg/l for cadmium and lead, respectively. The accuracy of the results was supported by the analysis of Seronorm TM Trace Elements Urine Batch no.101021 [ru

  16. Drosophila subobscura flies adapted to low lead concentration carry no fitness cost

    International Nuclear Information System (INIS)

    Kalajdzic, Predrag; Kenig, Bojan; Andjelkovic, Marko

    2015-01-01

    As a response to the long-term presence of heavy metals in the environment, populations can evolve resistance. Its maintenance may have detrimental effect on population's fitness, causing a fitness cost. Lead is one of the widely distributed elements in the environment exhibiting high toxicity on organisms. By analyzing developmental stages viability and developmental time, we evaluated fitness cost in Drosophila subobscura flies adapted to low lead concentration and control flies derived from the same wild population, as well as their hybrids. Significant changes in specific developmental stages viability were detected in both lines, as well as their hybrids, suggesting complex response to low lead concentration. The results show that a long-term exposure to low lead concentration may have a significant impact on a population's survival, especially in a changing environment conditions. - Highlights: • We analyzed fitness cost in Drosophila subobscura flies reared on lead (Pb) for 37 generations. • Two fitness components, developmental stages viability and developmental time, were analyzed. • A long-term exposure to low lead concentration exhibits a complex adaptation response in D. subobscura flies. • A long-term exposure to low lead concentration decreases viability of population in a changing environment condition. - This study suggests that wild species under a long-term exposure to low concentrations of heavy metals could be in increased risk of population reduction under changing environments

  17. Leading and lagging indicators of occupational health and safety: The moderating role of safety leadership.

    Science.gov (United States)

    Sheehan, Cathy; Donohue, Ross; Shea, Tracey; Cooper, Brian; Cieri, Helen De

    2016-07-01

    In response to the call for empirical evidence of a connection between leading and lagging indicators of occupational health and safety (OHS), the first aim of the current research is to consider the association between leading and lagging indicators of OHS. Our second aim is to investigate the moderating effect of safety leadership on the association between leading and lagging indicators. Data were collected from 3578 employees nested within 66 workplaces. Multi-level modelling was used to test the two hypotheses. The results confirm an association between leading and lagging indicators of OHS as well as the moderating impact of middle management safety leadership on the direct association. The association between leading and lagging indicators provides OHS practitioners with useful information to substantiate efforts within organisations to move away from a traditional focus on lagging indicators towards a preventative focus on leading indicators. The research also highlights the important role played by middle managers and the value of OHS leadership development and investment at the middle management level. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. The moderating role of absorptive capacity and the differential effects of acquisitions and alliances on Big Pharma firms' innovation performance

    NARCIS (Netherlands)

    Fernald, K D S; Pennings, H.P.G.; van den Bosch, J F; Commandeur, H.R.; Claassen, H.J.H.M.

    2017-01-01

    In the context of increased pharmaceutical innovation deficits and Big Pharma blockbusters' patent expirations, this paper examines the moderating role of firms' absorptive capacity in external innovation activities of Big Pharma firms. The study indicates a rising interest of Big Pharma in

  19. The moderating role of absorptive capacity and the differential effects of acquisitions and alliances on Big Pharma firms' innovation performance

    NARCIS (Netherlands)

    K.D.S.-G. Fernald (Kenneth); H.P.G. Pennings (Enrico); Van Den Bosch, J.F.; H.R. Commandeur (Harry); H.J.H.M. Claassen (Eric)

    2017-01-01

    textabstractIn the context of increased pharmaceutical innovation deficits and Big Pharma blockbusters' patent expirations, this paper examines the moderating role of firms' absorptive capacity in external innovation activities of Big Pharma firms. The study indicates a rising interest of Big Pharma

  20. Monitoring of lead levels in spices and food colors using atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Rahman, S.; Khalid, N.; Ahmad, S.

    2001-01-01

    The concentration of lead has been monitored in various commercial brands of spices and food colours using atomic absorption spectrometry after digestion in a mixture of nitric acid and perchloric acid. The reliability of the procedure used was checked by analyzing the standard reference materials namely wheat flour (NBS-1567) and rice flour (NBS-1568), for their lead contents. The determined concentration of lead ranged from 5.60 to 10.12 mg g-1 in food spices and from 1.62 to 1.81 mg g-1 in food colours. The study revealed that the piper nigrum contains higher lead contents as compared to capsicum. The effect of processing/milling on the concentration of lead in spices was also studied and discussed. The daily intake of lead by adults through spices and food colours was estimated and was found to be within the recommended WHO tolerance levels. (author)

  1. Absorption of fast waves at moderate to high ion cyclotron harmonics on DIII-D

    International Nuclear Information System (INIS)

    Pinsker, R.I.; Porkolab, M.; Heidbrink, W.W.; Luo, Y.; Petty, C.C.; Prater, R.; Choi, M.; Schaffner, D.A.; Baity, F.W.; Fredd, E.; Hosea, J.C.; Harvey, R.W.; Smirnov, A.P.; Murakami, M.; Zeeland, M.A. Van

    2006-01-01

    The absorption of fast Alfven waves (FW) by ion cyclotron harmonic damping in the range of harmonics from 4th to 8th is studied theoretically and with experiments in the DIII-D tokamak. A formula for linear ion cyclotron absorption on ions with an arbitrary distribution function which is symmetric about the magnetic field is used to estimate the single-pass damping for various cases of experimental interest. It is found that damping on fast ions from neutral beam injection can be significant even at the 8th harmonic if the fast ion beta, the beam injection energy and the background plasma density are high enough and the beam injection geometry is appropriate. The predictions are tested in several L-mode experiments in DIII-D with FW power at 60 MHz and at 116 MHz. It is found that 4th and 5th harmonic absorption of the 60 MHz power on the beam ions can be quite strong, but 8th harmonic absorption of the 116 MHz power appears to be weaker than expected. The linear modelling predicts a strong dependence of the 8th harmonic absorption on the initial pitch-angle of the injected beam, which is not observed in the experiment. Possible explanations of the discrepancy are discussed

  2. Direct Numerical Simulation of Flows over an NACA-0012 Airfoil at Low and Moderate Reynolds Numbers

    Science.gov (United States)

    Balakumar, P.

    2017-01-01

    Direct numerical simulations (DNS) of flow over an NACA-0012 airfoil are performed at a low and a moderate Reynolds numbers of Re(sub c)=50 times10(exp 3) and 1times 10(exp 6). The angles of attack are 5 and 15 degrees at the low and the moderate Reynolds number cases respectively. The three-dimensional unsteady compressible Navier-Stokes equations are solved using higher order compact schemes. The flow field in the low Reynolds number case consists of a long separation bubble near the leading-edge region and an attached boundary layer on the aft part of the airfoil. The shear layer that formed in the separated region persisted up to the end of the airfoil. The roles of the turbulent diffusion, advection, and dissipation terms in the turbulent kinetic-energy balance equation change as the boundary layer evolves over the airfoil. In the higher Reynolds number case, the leading-edge separation bubble is very small in length and in height. A fully developed turbulent boundary layer is observed in a short distance downstream of the reattachment point. The boundary layer velocity near the wall gradually decreases along the airfoil. Eventually, the boundary layer separates near the trailing edge. The Reynolds stresses peak in the outer part of the boundary layer and the maximum amplitude also gradually increases along the chord.

  3. Radiation trapping in atomic absorption spectroscopy at lead determination in different matricies

    International Nuclear Information System (INIS)

    El-Gohary, Z.

    2005-01-01

    The determination of lead by flame atomic absorption analysis in the presence of Sn and Fe atoms and different matrices such as OH and SO 3 was investigated with the objective of understanding the spectral interference processes at the analytical lines 283.31 nm for a wide range of concentration. The radiation trapping factor was interpreted and evaluated assuming Voigt distribution of the atomic and rotational lines in the flame. The radiation trapping factor was increased by increasing the number density (plasma of the absorbing medium is optically thick). In plasma, there is a certain point of equilibrium between the trapping and the escaping of radiation, which is relevant to 50% of absorption. The spectral background interference can cause a variation of the number density at equilibrium point as a result of the degree of overlap with the analytical line. The spectral background interference can be easily avoided by using another resonance absorption line for the analysis. The chemical modification of the matrix is applied to minimize the interference effect. Nitric acid, ammonium nitrate and magnesium nitrate are most commonly recommended as matrix modifiers

  4. Measurement of mass attenuation coefficients of moderate-to-high atomic-number elements at low photon energies

    International Nuclear Information System (INIS)

    Tajuddin, A.A.; Chong, C.S.; Shukri, A.; Bradley, D.A.

    1995-01-01

    Mass attenuation coefficients for 12 selected moderate-to-high atomic-number elements have been obtained from good-geometry measurements made at five 241 Am photon energies of significant emission intensity. Particular interest focuses on measured values for photon energies close to absorption edges. Comparisons with renormalized cross-section predictions indicate agreement to within stated error limits for the majority of cases. Significant discrepancies (> 10%) are noted for Ta at 17.8 and 26.3 keV and W at 59.5 keV. Some support for a discrepancy between measurement and theory for W in the region of 60 keV is found in the reported measurements of others. (author)

  5. Small- bowel mucosal changes and antibody responses after low- and moderate-dose gluten challenge in celiac disease

    Directory of Open Access Journals (Sweden)

    Lähdeaho Marja-Leena

    2011-11-01

    Full Text Available Abstract Background Due to the restrictive nature of a gluten-free diet, celiac patients are looking for alternative therapies. While drug-development programs include gluten challenges, knowledge regarding the duration of gluten challenge and gluten dosage is insufficient. We challenged adult celiac patients with gluten with a view to assessing the amount needed to cause some small-bowel mucosal deterioration. Methods Twenty-five celiac disease adults were challenged with low (1-3 g or moderate (3-5g doses of gluten daily for 12 weeks. Symptoms, small-bowel morphology, densities of CD3+ intraepithelial lymphocytes (IELs and celiac serology were determined. Results Both moderate and low amounts of gluten induced small-bowel morphological damage in 67% of celiac patients. Moderate gluten doses also triggered mucosal inflammation and more gastrointestinal symptoms leading to premature withdrawals in seven cases. In 22% of those who developed significant small- intestinal damage, symptoms remained absent. Celiac antibodies seroconverted in 43% of the patients. Conclusions Low amounts of gluten can also cause significant mucosal deterioration in the majority of the patients. As there are always some celiac disease patients who will not respond within these conditions, sample sizes must be sufficiently large to attain to statistical power in analysis.

  6. Atomic absorption spectrometric determination of copper, zinc, and lead in geological materials

    Science.gov (United States)

    Sanzolone, R.F.; Chao, T.T.

    1976-01-01

    An atomic absorption spectrometric method is described for the determination of copper, zinc, and lead in geological materials. The sample is digested with HF-HCl-H2O2; the final solution for analysis is in 10 % (v/v) HCl. Copper and zinc are determined directly by aspirating the solution into an air-acetylene flame. A separate aliquot of the solution is used for determination of lead; lead is extracted into TOPO-MIBK from the acidic solution in the presence of iodide and ascorbic acid. For a 0.50-g sample, the limits of determination are 10-2000 p.p.m. for Cu and Zn, and 5-5000 p.p.m. for Pb. As much as 40 % Fe or Ca. and 10 % Al, Mg, or Mn in the sample do not interfere. The proposed method can be applied to the determination of copper, zinc, and lead in a wide range of geological materials including iron- and manganese-rich, calcareous and carbonate samples. ?? 1976.

  7. Neutron moderation at very low temperatures (1691)

    International Nuclear Information System (INIS)

    Lacaze, A.

    1961-04-01

    Starting from Harwell experiment carried out inside a low-power reactor, we intended to maintain a liquid hydrogen cell in a channel of the EL3 reactor (at Saclay) whose thermal neutrons flux is 10 14 neutrons/cm 2 /s. We tried to work out a device giving off an important beam of cold neutrons and able to operate in a way as automatic as possible during many consecutive day without a stop. Several circuits have already been achieved at very low temperatures but they brought out volumes and fluxes much lower than those we used this time. The difficulties we have met in carrying out such a device arose on the one hand from the very high energy release to which any kind of experiment is inevitably submitted when placed near the core of the reactor, on the other, hand from the very little room which is available in experimental channels of reactors. In such condition, it is necessary to use a moderator as effective as possible. This study is divided into three parts ; in the first part, we try to determine: a) conditions in which moderation takes place, hence the volume of the cell; b) materials likely to be used at low temperature and in pile; c) cooling system; hence we had to study fluid flow conditions at very low temperatures in very long ducts. The second part is devoted to the description of the device. The third part ventilates the results we have obtained. (author) [fr

  8. Selection of micronutrients used along with DMSA in the treatment of moderately lead intoxicated mice

    Energy Technology Data Exchange (ETDEWEB)

    Liao, Yingjun [China Medical University, Department of Physiology, School of Basic Medicine, Shenyang, Liaoning (China); Yu, Fei; Zhi, Xuping; An, Li; Yang, Jun [China Medical University, Department of Nutrition and Food Hygiene, School of Public Health, Shenyang, Liaoning (China); Jin, Yaping; Lu, Chunwei; Li, Gexin [China Medical University, Department of Environmental and Occupational Health, School of Public Health, Shenyang, Liaoning (China)

    2008-01-15

    The objective of this study was to explore the optimum combination of micronutrients used with 2,3-dimercaptosuccinic acid (DMSA) in the treatment of moderately lead-intoxicated mice. Experiment was carried out based on the orthogonal design L{sub 8}(2{sup 7}) setting six factors with two different levels of each, and eight groups of mice were needed. Mice were exposed to lead by drinking water contaminated with 0.1% lead acetate for four consecutive weeks, and then supplemented by gavage with different combinations of micronutrients with and without DMSA as designed in the orthogonal table. Lead levels in blood, liver, kidney, brain and bone and activities of blood {delta}-aminolevulinic acid dehydratase (ALAD) were analyzed after cessation of supplementation. The results suggested that DMSA was the only factor which could decrease significantly lead levels in blood, liver, kidney and bone; calcium and ascorbic acid were the notable factors decreasing lead levels in blood, liver, kidney, bone and brain; zinc and calcium were the notable factors reversing the lead-inhibited activities of blood ALAD; taurine was the notable factor decreasing lead levels in kidney and brain; and thiamine was the notable factor decreasing lead levels in brain. The lowest lead level in blood, liver, kidney and bone was shown in the mice supplemented with combination of calcium and ascorbic acid along with DMSA. In conclusion, the optimum combination of micronutrients used with DMSA suggested in present study was calcium and ascorbic acid, which seemed to potentiate the chelating efficacy of DMSA in the treatment of moderately lead intoxicated mice. (orig.)

  9. Different training responses to eccentric endurance exercise at low and moderate altitudes in pre-diabetic men: a pilot study.

    Science.gov (United States)

    Klarod, Kultida; Philippe, Marc; Gatterer, Hannes; Burtscher, Martin

    2017-01-01

    This pilot study aimed (a) to evaluate the effects of eccentric exercise training at low and moderate altitudes on physical fitness in pre-diabetic men and (b) to establish whether or not oxidative stress levels and antioxidant status were associated with performance improvements. In this crossover trial, five pre-diabetic men conducted nine downhill walking sessions (3 days/week, 3 consecutive weeks) at low altitude (from 1360 to 850 m) and one year later at moderate altitude (from 2447 to 2000 m). Exercise testing and the determination of parameters of oxidative stress and antioxidant capacity were performed pre- and post-training. The biological antioxidant activity of plasma (BAP) increased after eccentric training at moderate altitude ( p  training at moderate-altitude training ( p  = 0.009). Maximum power output improved after training at low altitude and the changes were significantly related to baseline BAP/dROMs ratio ( r  = 0.90). No decrease was seen for fasting plasma glucose. Eccentric exercise training in pre-diabetic men improved performance only when performed at low altitude and this improvement was positively related to the baseline BAP/dROMs ratio. In contrast, 3 weeks of eccentric exercise training increased BAP levels and the BAP/dROMs ratio only at moderate altitude without improving the performance. Thus, one might speculate that the BAP/dROMs ratio has to increase before performance improvements occur at moderate altitude.

  10. Spatial distribution of neutrons in paraffin moderator surrounding a lead target irradiated with protons at intermediate energies

    CERN Document Server

    Adam, J; Bradnova, V

    2002-01-01

    The distribution of neutrons emitted during the irradiation with 0.65, 1.0 and 1.5 GeV protons from a lead target (O / = 8 cm, l = 20 cm) and moderated by a surrounding paraffin moderator of 6 cm thick was studied with a radiochemical sensor along the beam axis on top of the moderator. Small sup 1 sup 3 sup 9 La-sensors of approximately 1 g were used to measure essentially the thermal neutron fluence at different depths near the surface: i.e., on top of the moderator, in 10 mm deep holes and in 20 mm deep holes. The reaction sup 1 sup 3 sup 9 La(n, gamma) sup 1 sup 4 sup 0 La (tau sub 1 sub / sub 2 = 40.27 h) was studied using standard procedures of gamma spectroscopy and data analysis. The neutron induced activity of sup 1 sup 4 sup 0 La increases strongly with the depth of the hole inside the moderator, its activity distribution along the beam direction on top of the moderator has its maximum about 10 cm downstream the entrance of the protons into the lead and the induced activity increases about linearity ...

  11. Circuit Board Analysis for Lead by Atomic Absorption Spectroscopy in a Course for Nonscience Majors

    Science.gov (United States)

    Weidenhammer, Jeffrey D.

    2007-01-01

    A circuit board analysis of the atomic absorption spectroscopy, which is used to measure lead content in a course for nonscience majors, is being presented. The experiment can also be used to explain the potential environmental hazards of unsafe disposal of various used electronic equipments.

  12. Outpatient rapid 4-step desensitization for gynecologic oncology patients with mild to low-risk, moderate hypersensitivity reactions to carboplatin/cisplatin.

    Science.gov (United States)

    Li, Quan; Cohn, David; Waller, Allyson; Backes, Floor; Copeland, Larry; Fowler, Jeffrey; Salani, Ritu; O'Malley, David

    2014-10-01

    The primary objective of this study is to assess the efficacy and safety of an outpatient, 4-step, one-solution desensitization protocol in gynecologic oncology patients with history of mild to low-risk, moderate hypersensitivity reactions (HSRs) to platinums (carboplatin and cisplatin). This was a single institutional retrospective review. Gynecologic oncology patients with a documented history of mild or low-risk, moderate immediate HSRs to carboplatin/cisplatin and continued treatment with 4-step, one-solution desensitization protocols in the outpatient infusion center were included. Patients with delayed HSRs or immediate high-risk, moderate or severe HSRs were excluded. The primary end point was the rate of successful administrations of each course of platinums. From January 2011 to June 2013, eighteen eligible patients were evaluated for outpatient 4-step, one-solution desensitization. Thirteen patients had a history of HSRs to carboplatin and 5 with HSRs to cisplatin. All of 18 patients successfully completed 94 (98.9%) of 95 desensitization courses in the outpatient infusion center. Eight of 8 (100%) patients with initial mild HSRs completed 29/29 (100%) desensitization courses, and 9 of 10 (90%) of patients with initial moderate HSRs completed 65/66 (94%) desensitization courses. In total, 65/95 (68%) desensitizations resulted in no breakthrough reactions, and mild, moderate and severe breakthrough reactions were seen in 19%, 12% and 1% desensitizations, respectively. No patients were hospitalized during desensitization. The outpatient rapid, 4-step, one-solution desensitization protocol was effective and appeared safe among gynecologic oncology patients who experienced mild to low-risk, moderate HSRs to carboplatin/cisplatin. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Exciton-Dominated Core-Level Absorption Spectra of Hybrid Organic–Inorganic Lead Halide Perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Vorwerk, Christian [Institut für Physik and IRIS Adlershof, Humboldt-Universität zu Berlin, European Theoretical Spectroscopy; Hartmann, Claudia [Renewable Energy, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 14109 Berlin, Germany; Cocchi, Caterina [Institut für Physik and IRIS Adlershof, Humboldt-Universität zu Berlin, European Theoretical Spectroscopy; Sadoughi, Golnaz [Clarendon Laboratory, Department of Physics, University of Oxford, Oxford OX1 3PU, United Kingdom; Habisreutinger, Severin N. [Clarendon Laboratory, Department of Physics, University of Oxford, Oxford OX1 3PU, United Kingdom; Chemistry and Nanoscience Center, National Renewable Energy Laboratory (NREL), Golden, Colorado, United States; Félix, Roberto [Renewable Energy, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 14109 Berlin, Germany; Wilks, Regan G. [Renewable Energy, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 14109 Berlin, Germany; Energy Materials In-Situ Laboratory Berlin (EMIL), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 12489 Berlin, Germany; Snaith, Henry J. [Clarendon Laboratory, Department of Physics, University of Oxford, Oxford OX1 3PU, United Kingdom; Bär, Marcus [Renewable Energy, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 14109 Berlin, Germany; Energy Materials In-Situ Laboratory Berlin (EMIL), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 12489 Berlin, Germany; Draxl, Claudia [Institut für Physik and IRIS Adlershof, Humboldt-Universität zu Berlin, European Theoretical Spectroscopy

    2018-03-23

    In a combined theoretical and experimental work, we investigate X-ray absorption near-edge structure spectroscopy of the I L3 and the Pb M5 edges of the methylammonium lead iodide (MAPbI3) hybrid inorganic-organic perovskite and its binary phase PbI2. The absorption onsets are dominated by bound excitons with sizable binding energies of a few hundred millielectronvolts and pronounced anisotropy. The spectra of both materials exhibit remarkable similarities, suggesting that the fingerprints of core excitations in MAPbI3 are essentially given by its inorganic component, with negligible influence from the organic groups. The theoretical analysis complementing experimental observations provides the conceptual insights required for a full characterization of this complex material.

  14. Low absorption InP/InGaAs-MQW phase shifters for optical switching

    NARCIS (Netherlands)

    Vreeburg, C.G.M.; Smit, M.K.; Bachmann, M.; Kyburz, R.; Krähenbühl, R.; Gini, E.; Melchior, H.; Shi, L.; Spiekman, L.H.; Leijtens, X.J.M.

    1995-01-01

    InP/InGaAs-MQW phase shifters with low absorption loss and low electroabsorption loss have been realized. Phase shift efficiency for TE-polarized light at lambda =1.55 mu m was 6.8 degrees V/sup -1/ mm/sup -1/ with negligible absorption loss and at lambda =1.51 mu m the efficiency was 8.9 degrees

  15. Efficacy of Low-dose (2 millicurie) versus Standard-dose (4 millicurie) Radioiodine Treatment for Cats with Mild-to-Moderate Hyperthyroidism.

    Science.gov (United States)

    Lucy, J M; Peterson, M E; Randolph, J F; Scrivani, P V; Rishniw, M; Davignon, D L; Thompson, M S; Scarlett, J M

    2017-03-01

    Radioiodine ( 131 I) is effective treatment for hyperthyroidism in cats, but optimal dose to restore euthyroidism without inducing hypothyroidism is unclear. Treatment-induced hypothyroidism can lead to azotemia and reduced duration of survival. To compare efficacy and short-term outcomes of low-dose 131 I versus higher, standard-dose 131 I as treatment for hyperthyroidism. A total of 189 client-owned cats undergoing 131 I treatment for mild-to-moderate hyperthyroidism (serum T 4 ≥ 4.0 μg/dL and hyperthyroidism, overt hypothyroidism (low T 4 , high TSH), subclinical hypothyroidism (normal T 4 , high TSH), and azotemia. There was no significant difference in prevalence of cats with persistent hyperthyroidism between standard- and low-dose treatment groups at 3 (0% versus 5.3%; P = .34) and 6 (0% versus 3.3%; P = .51) months. Overt (18% versus 1%; P = .0005) or subclinical (46% versus 21%; P = .004) hypothyroidism was more common in cats at 6 months after standard-dose 131 I. No difference in incidence of azotemia existed between groups, but cats treated with standard-dose 131 I had higher creatinine concentrations (P effective for cats with mild-to-moderate hyperthyroidism, as evidenced by a cure rate of >95% with reduced frequency of iatrogenic hypothyroidism and azotemia. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  16. ``New'' energy states lead to phonon-less optoelectronic properties in nanostructured silicon

    Science.gov (United States)

    Singh, Vivek; Yu, Yixuan; Korgel, Brian; Nagpal, Prashant

    2014-03-01

    Silicon is arguably one of the most important technological material for electronic applications. However, indirect bandgap of silicon semiconductor has prevented optoelectronic applications due to phonon assistance required for photon light absorption/emission. Here we show, that previously unexplored surface states in nanostructured silicon can couple with quantum-confined energy levels, leading to phonon-less exciton-recombination and photoluminescence. We demonstrate size dependence (2.4 - 8.3 nm) of this coupling observed in small uniform silicon nanocrystallites, or quantum-dots, by direct measurements of their electronic density of states and low temperature measurements. To enhance the optical absorption of the these silicon quantum-dots, we utilize generation of resonant surface plasmon polariton waves, which leads to several fold increase in observed spectrally-resolved photocurrent near the quantum-confined bandedge states. Therefore, these enhanced light emission and absorption enhancement can have important implications for applications of nanostructured silicon for optoelectronic applications in photovoltaics and LEDs.

  17. Multifunctional hybrids for electromagnetic absorption

    International Nuclear Information System (INIS)

    Huynen, I.; Quievy, N.; Bailly, C.; Bollen, P.; Detrembleur, C.; Eggermont, S.; Molenberg, I.; Thomassin, J.M.; Urbanczyk, L.

    2011-01-01

    Highlights: → EM absorption requires low dielectric constant and ∼1 S/m electrical conductivity. → New hybrids were processed with CNT-filled polymer foam inserted in Al honeycomb. → The EM absorption in the GHz range is superior to any known material. → A closed form model is used to guide the design of the hybrid. → The architectured material is light with potential for thermal management. - Abstract: Electromagnetic (EM) interferences are ubiquitous in modern technologies and impact on the reliability of electronic devices and on living cells. Shielding by EM absorption, which is preferable over reflection in certain instances, requires combining a low dielectric constant with high electrical conductivity, which are antagonist properties in the world of materials. A novel class of hybrid materials for EM absorption in the gigahertz range has been developed based on a hierarchical architecture involving a metallic honeycomb filled with a carbon nanotube-reinforced polymer foam. The waveguide characteristics of the honeycomb combined with the performance of the foam lead to unexpectedly large EM power absorption over a wide frequency range, superior to any known material. The peak absorption frequency can be tuned by varying the shape of the honeycomb unit cell. A closed form model of the EM reflection and absorption provides a tool for the optimization of the hybrid. This designed material sets the stage for a new class of sandwich panels combining high EM absorption with mass efficiency, stiffness and thermal management.

  18. Urban airborne lead: X-ray absorption spectroscopy establishes soil as dominant source.

    Science.gov (United States)

    Pingitore, Nicholas E; Clague, Juan W; Amaya, Maria A; Maciejewska, Beata; Reynoso, Jesús J

    2009-01-01

    Despite the dramatic decrease in airborne lead over the past three decades, there are calls for regulatory limits on this potent pediatric neurotoxin lower even than the new (2008) US Environmental Protection Agency standard. To achieve further decreases in airborne lead, what sources would need to be decreased and what costs would ensue? Our aim was to identify and, if possible, quantify the major species (compounds) of lead in recent ambient airborne particulate matter collected in El Paso, TX, USA. We used synchrotron-based XAFS (x-ray absorption fine structure) to identify and quantify the major Pb species. XAFS provides molecular-level structural information about a specific element in a bulk sample. Pb-humate is the dominant form of lead in contemporary El Paso air. Pb-humate is a stable, sorbed complex produced exclusively in the humus fraction of Pb-contaminated soils; it also is the major lead species in El Paso soils. Thus such soil must be the dominant source, and its resuspension into the air, the transfer process, providing lead particles to the local air. Current industrial and commercial activity apparently is not a major source of airborne lead in El Paso, and presumably other locales that have eliminated such traditional sources as leaded gasoline. Instead, local contaminated soil, legacy of earlier anthropogenic Pb releases, serves as a long-term reservoir that gradually leaks particulate lead to the atmosphere. Given the difficulty and expense of large-scale soil remediation or removal, fugitive soil likely constrains a lower limit for airborne lead levels in many urban settings.

  19. Copper Deficiency Leads to Anemia, Duodenal Hypoxia, Upregulation of HIF-2α and Altered Expression of Iron Absorption Genes in Mice

    Science.gov (United States)

    Matak, Pavle; Zumerle, Sara; Mastrogiannaki, Maria; El Balkhi, Souleiman; Delga, Stephanie; Mathieu, Jacques R. R.; Canonne-Hergaux, François; Poupon, Joel; Sharp, Paul A.; Vaulont, Sophie; Peyssonnaux, Carole

    2013-01-01

    Iron and copper are essential trace metals, actively absorbed from the proximal gut in a regulated fashion. Depletion of either metal can lead to anemia. In the gut, copper deficiency can affect iron absorption through modulating the activity of hephaestin - a multi-copper oxidase required for optimal iron export from enterocytes. How systemic copper status regulates iron absorption is unknown. Mice were subjected to a nutritional copper deficiency-induced anemia regime from birth and injected with copper sulphate intraperitoneally to correct the anemia. Copper deficiency resulted in anemia, increased duodenal hypoxia and Hypoxia inducible factor 2α (HIF-2α) levels, a regulator of iron absorption. HIF-2α upregulation in copper deficiency appeared to be independent of duodenal iron or copper levels and correlated with the expression of iron transporters (Ferroportin - Fpn, Divalent Metal transporter – Dmt1) and ferric reductase – Dcytb. Alleviation of copper-dependent anemia with intraperitoneal copper injection resulted in down regulation of HIF-2α-regulated iron absorption genes in the gut. Our work identifies HIF-2α as an important regulator of iron transport machinery in copper deficiency. PMID:23555700

  20. Spatial distribution of neutrons in paraffin moderator surrounding a lead target irradiated with protons at intermediate energies

    International Nuclear Information System (INIS)

    Adam, J.; Barabanov, M.Yu.; Bradnova, V.

    2002-01-01

    The distribution of neutrons emitted during the irradiation with 0.65, 1.0 and 1.5 GeV protons from a lead target (O / = 8 cm, l = 20 cm) and moderated by a surrounding paraffin moderator of 6 cm thick was studied with a radiochemical sensor along the beam axis on top of the moderator. Small 139 La-sensors of approximately 1 g were used to measure essentially the thermal neutron fluence at different depths near the surface: i.e., on top of the moderator, in 10 mm deep holes and in 20 mm deep holes. The reaction 139 La(n, γ) 140 La (τ 1/2 = 40.27 h) was studied using standard procedures of gamma spectroscopy and data analysis. The neutron induced activity of 140 La increases strongly with the depth of the hole inside the moderator, its activity distribution along the beam direction on top of the moderator has its maximum about 10 cm downstream the entrance of the protons into the lead and the induced activity increases about linearity with the proton energy. Some comparisons of the experimental results with model estimations based on the LAHET code are also presented. The experiments were carried out using the Nuclotron accelerator of the Laboratory of High Energies (JINR)

  1. Absorption of low-frequency electromagnetic waves by plasma in electromagnetic trap

    International Nuclear Information System (INIS)

    D'yakov, V.E.

    1984-01-01

    Absorption of electromagnetic waves in plasma of the electromagnetic trap is investigated. An integro-differential equation describing the behaviour of the electrical and magnetic fields of the wave is obtained. The wave has a component along the plasma inhomogeneity axis. Solution of this equation is found within the low frequency range corresponding to the anomalous skin-effect. The possibility of ion-acoustic waves excitation is demonstrated. Expressions are found for reflection, absorption and transformation coefficients

  2. A review of lung-to-blood absorption rates for radon progeny

    International Nuclear Information System (INIS)

    Marsh, J. W.; Bailey, M. R.

    2013-01-01

    The International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model (HRTM) treats clearance of materials from the respiratory tract as a competitive process between absorption into blood and particle transport to the alimentary tract and lymphatics. The ICRP recommended default absorption rates for lead and polonium (Type M) in ICRP Publication 71 but stated that the values were not appropriate for short-lived radon progeny. This paper reviews and evaluates published data from volunteer and laboratory animal experiments to estimate the HRTM absorption parameter values for short-lived radon progeny. Animal studies showed that lead ions have two phases of absorption: ∼10 % absorbed with a half-time of ∼15 min, the rest with a half-time of ∼10 h. The studies also indicated that some of the lead ions were bound to respiratory tract components. Bound fractions, f b , for lead were estimated from volunteer and animal studies and ranged from 0.2 to 0.8. Based on the evaluations of published data, the following HRTM absorption parameter values were derived for lead as a decay product of radon: f r = 0.1, s r = 100 d -1 , s s = 1.7 d -1 , f b = 0.5 and s b = 1.7 d -1 . Effective doses calculated assuming these absorption parameter values instead of a single absorption half-time of 10 h with no binding (as has generally been assumed) are only a few per cent higher. However, as there is some conflicting evidence on the absorption kinetics for radon progeny, dose calculations have been carried out for different sets of absorption parameter values derived from different studies. The results of these calculations are discussed. (authors)

  3. Adaptation of a lead-tolerant population of Agrostis tenuis to low soil fertility

    Energy Technology Data Exchange (ETDEWEB)

    Jowett, D

    1959-07-04

    A population of Agrostis tenuis growing on lead ore grindings at Goginan was found to be tolerant of lead. The pasture populations responded to calcium and phosphate, whereas the lead mine population showed no response to calcium and a lesser response to phosphate. The lead mine population data was included. A considerable range of adaption to soil mineral levels has now been found in this species. It has populations tolerant of lead, copper, and nickel poisoning, and of low levels of calcium and phosphate. In lead mine habitats A tenuis is not replaced by A. canina as in more normal habitats. A tenuis is subject to the most extreme conditions of low fertility. 4 tables.

  4. Chronic exposure to low frequency noise at moderate levels causes impaired balance in mice.

    Directory of Open Access Journals (Sweden)

    Haruka Tamura

    Full Text Available We are routinely exposed to low frequency noise (LFN; below 0.5 kHz at moderate levels of 60-70 dB sound pressure level (SPL generated from various sources in occupational and daily environments. LFN has been reported to affect balance in humans. However, there is limited information about the influence of chronic exposure to LFN at moderate levels for balance. In this study, we investigated whether chronic exposure to LFN at a moderate level of 70 dB SPL affects the vestibule, which is one of the organs responsible for balance in mice. Wild-type ICR mice were exposed for 1 month to LFN (0.1 kHz and high frequency noise (HFN; 16 kHz at 70 dB SPL at a distance of approximately 10-20 cm. Behavior analyses including rotarod, beam-crossing and footprint analyses showed impairments of balance in LFN-exposed mice but not in non-exposed mice or HFN-exposed mice. Immunohistochemical analysis showed a decreased number of vestibular hair cells and increased levels of oxidative stress in LFN-exposed mice compared to those in non-exposed mice. Our results suggest that chronic exposure to LFN at moderate levels causes impaired balance involving morphological impairments of the vestibule with enhanced levels of oxidative stress. Thus, the results of this study indicate the importance of considering the risk of chronic exposure to LFN at a moderate level for imbalance.

  5. Absorption properties of water-in-oil emulsions in the low THz frequency range

    DEFF Research Database (Denmark)

    Møller, Uffe; Folkenberg, Jacob Riis; Jepsen, Peter Uhd

    We use transmission THz spectroscopy to investigate the absorption properties of water-in-oil emulsions with water content varying in the 0-20% range, relevant for a range of food products. We find that at low frequencies the effective absorption coefficient of the emulsion is suppressed compared...... to bulk water....

  6. Urban airborne lead: X-ray absorption spectroscopy establishes soil as dominant source.

    Directory of Open Access Journals (Sweden)

    Nicholas E Pingitore

    Full Text Available BACKGROUND: Despite the dramatic decrease in airborne lead over the past three decades, there are calls for regulatory limits on this potent pediatric neurotoxin lower even than the new (2008 US Environmental Protection Agency standard. To achieve further decreases in airborne lead, what sources would need to be decreased and what costs would ensue? Our aim was to identify and, if possible, quantify the major species (compounds of lead in recent ambient airborne particulate matter collected in El Paso, TX, USA. METHODOLOGY/PRINCIPAL FINDINGS: We used synchrotron-based XAFS (x-ray absorption fine structure to identify and quantify the major Pb species. XAFS provides molecular-level structural information about a specific element in a bulk sample. Pb-humate is the dominant form of lead in contemporary El Paso air. Pb-humate is a stable, sorbed complex produced exclusively in the humus fraction of Pb-contaminated soils; it also is the major lead species in El Paso soils. Thus such soil must be the dominant source, and its resuspension into the air, the transfer process, providing lead particles to the local air. CONCLUSIONS/SIGNIFICANCE: Current industrial and commercial activity apparently is not a major source of airborne lead in El Paso, and presumably other locales that have eliminated such traditional sources as leaded gasoline. Instead, local contaminated soil, legacy of earlier anthropogenic Pb releases, serves as a long-term reservoir that gradually leaks particulate lead to the atmosphere. Given the difficulty and expense of large-scale soil remediation or removal, fugitive soil likely constrains a lower limit for airborne lead levels in many urban settings.

  7. Light transport in turbid media with non-scattering, low-scattering and high absorption heterogeneities based on hybrid simplified spherical harmonics with radiosity model.

    Science.gov (United States)

    Yang, Defu; Chen, Xueli; Peng, Zhen; Wang, Xiaorui; Ripoll, Jorge; Wang, Jing; Liang, Jimin

    2013-01-01

    Modeling light propagation in the whole body is essential and necessary for optical imaging. However, non-scattering, low-scattering and high absorption regions commonly exist in biological tissues, which lead to inaccuracy of the existing light transport models. In this paper, a novel hybrid light transport model that couples the simplified spherical harmonics approximation (SPN) with the radiosity theory (HSRM) was presented, to accurately describe light transport in turbid media with non-scattering, low-scattering and high absorption heterogeneities. In the model, the radiosity theory was used to characterize the light transport in non-scattering regions and the SPN was employed to handle the scattering problems, including subsets of low-scattering and high absorption. A Neumann source constructed by the light transport in the non-scattering region and formed at the interface between the non-scattering and scattering regions was superposed into the original light source, to couple the SPN with the radiosity theory. The accuracy and effectiveness of the HSRM was first verified with both regular and digital mouse model based simulations and a physical phantom based experiment. The feasibility and applicability of the HSRM was then investigated by a broad range of optical properties. Lastly, the influence of depth of the light source on the model was also discussed. Primary results showed that the proposed model provided high performance for light transport in turbid media with non-scattering, low-scattering and high absorption heterogeneities.

  8. In Situ Solid-State Reactions Monitored by X-ray Absorption Spectroscopy: Temperature-Induced Proton Transfer Leads to Chemical Shifts.

    Science.gov (United States)

    Stevens, Joanna S; Walczak, Monika; Jaye, Cherno; Fischer, Daniel A

    2016-10-24

    The dramatic colour and phase alteration with the solid-state, temperature-dependent reaction between squaric acid and 4,4'-bipyridine has been probed in situ with X-ray absorption spectroscopy. The electronic and chemical sensitivity to the local atomic environment through chemical shifts in the near-edge X-ray absorption fine structure (NEXAFS) revealed proton transfer from the acid to the bipyridine base through the change in nitrogen protonation state in the high-temperature form. Direct detection of proton transfer coupled with structural analysis elucidates the nature of the solid-state process, with intermolecular proton transfer occurring along an acid-base chain followed by a domino effect to the subsequent acid-base chains, leading to the rapid migration along the length of the crystal. NEXAFS thereby conveys the ability to monitor the nature of solid-state chemical reactions in situ, without the need for a priori information or long-range order. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. CLINICAL STUDY TO EVALUATE THE VISUAL OUTCOME AND PATIENT COMFORT IN LASIK AND PHOTOREFRACTIVE KERATECTOMY IN LOW-TO-MODERATE MYOPIC ASTIGMATISM PATIENTS

    OpenAIRE

    Ashok Kumar P; Ananda Babu M; Radha Priyadharshini R; Jeevitha A

    2017-01-01

    BACKGROUND To evaluate visual outcomes following LASIK and Photorefractive Keratectomy (PRK) in low-to-moderate myopia and/or myopic astigmatism in age and refractive error matched eyes. MATERIALS AND METHODS Of a total 30 patients aged ≥21 years, 20 (40 eyes) underwent LASIK and 10 (20 eyes) underwent PRK for low-to-moderate myopia or myopic astigmatism. LASIK was performed with the Alcon wave light 500 and PRK with the alcohol application for epithelial removal. All abl...

  10. Coherent single-photon absorption by single emitters coupled to 1D nanophotonic waveguides

    DEFF Research Database (Denmark)

    Chen, Yuntian; Wubs, Martijn; Mørk, Jesper

    2012-01-01

    We have derived an efficient model that allows calculating the dynamical single-photon absorption of an emitter coupled to a waveguide. We suggest a novel and simple structure that leads to strong single-photon absorption.......We have derived an efficient model that allows calculating the dynamical single-photon absorption of an emitter coupled to a waveguide. We suggest a novel and simple structure that leads to strong single-photon absorption....

  11. Absorption-reduced waveguide structure for efficient terahertz generation

    Energy Technology Data Exchange (ETDEWEB)

    Pálfalvi, L., E-mail: palfalvi@fizika.ttk.pte.hu [Institute of Physics, University of Pécs, Ifjúság ú. 6, 7624 Pécs (Hungary); Fülöp, J. A. [MTA-PTE High-Field Terahertz Research Group, Ifjúság ú. 6, 7624 Pécs (Hungary); Szentágothai Research Centre, University of Pécs, Ifjúság ú. 20, 7624 Pécs (Hungary); Hebling, J. [Institute of Physics, University of Pécs, Ifjúság ú. 6, 7624 Pécs (Hungary); MTA-PTE High-Field Terahertz Research Group, Ifjúság ú. 6, 7624 Pécs (Hungary); Szentágothai Research Centre, University of Pécs, Ifjúság ú. 20, 7624 Pécs (Hungary)

    2015-12-07

    An absorption-reduced planar waveguide structure is proposed for increasing the efficiency of terahertz (THz) pulse generation by optical rectification of femtosecond laser pulses with tilted-pulse-front in highly nonlinear materials with large absorption coefficient. The structure functions as waveguide both for the optical pump and the generated THz radiation. Most of the THz power propagates inside the cladding with low THz absorption, thereby reducing losses and leading to the enhancement of the THz generation efficiency by up to more than one order of magnitude, as compared with a bulk medium. Such a source can be suitable for highly efficient THz pulse generation pumped by low-energy (nJ-μJ) pulses at high (MHz) repetition rates delivered by compact fiber lasers.

  12. Moderation control in low enriched 235U uranium hexafluoride packaging operations and transportation

    International Nuclear Information System (INIS)

    Dyer, R.H.; Kovac, F.M.; Pryor, W.A.

    1993-01-01

    Moderation control is the basic parameter for ensuring nuclear criticality safety during the packaging and transport of low 235 U enriched uranium hexafluoride before its conversion to nuclear power reactor fuel. Moderation control has permitted the shipment of bulk quantities in large cylinders instead of in many smaller cylinders and, therefore, has resulted in economies without compromising safety. Overall safety and uranium accountability have been enhanced through the use of the moderation control. This paper discusses moderation control and the operating procedures to ensure that moderation control is maintained during packaging operations and transportation

  13. EVALUATION OF ROTARY KILN INCINERATOR OPERATION AT LOW TO MODERATE TEMPERATURE CONDITIONS VOLUME 1. TECHNICAL RESULTS

    Science.gov (United States)

    A test program was performed at the Environmental Protection Agency Incineration Research Facility to study the effectiveness of incineration at low-to-moderate temperatures in decontaminating soils containing organic compounds with different volatilities (boiling points). The da...

  14. Lead contamination of environment in Meza Valley, Yugoslavia: some considerations on lead content in soil and plants

    Energy Technology Data Exchange (ETDEWEB)

    Djuric, D; Kerin, Z

    1970-01-01

    As part of a broad ecological study of lead contamination, soil samples and underground parts of some vegetables were analyzed for lead by the dithizone method. Vegetables fell into three groups: those with a relatively high Pb content (over 30 mg/kg); those with a medium Pb content (over 10 mg/kg); and those with a low Pb content (under 5 mg/kg). Variations in Pb content in the same kind of vegetables represented variations in soil Pb content and absorption. Variations between different kinds of vegetables were due to differences in plant physiology and capacity of absorption, shape and size of root, and depth of root in soil. Lead content was higher in vegetables grown in summer and fall than for the same vegetables grown in spring. Lead absorption coefficients were calculated for underground parts of vegetables according to the relation between the Pb content of the plant and total Pb content of soil and according to the relation between the Pb content of the plant and the AL-soluble Pb in soil (AL is the ammonium lactate acetic acid mixture). The latter method gave much less dispersed coefficients, indicating that AL-soluble Pb represents much more authoritative data for determining absorption coefficients than total soil Pb.

  15. A Low-Cost Quantitative Absorption Spectrophotometer

    Science.gov (United States)

    Albert, Daniel R.; Todt, Michael A.; Davis, H. Floyd

    2012-01-01

    In an effort to make absorption spectrophotometry available to high school chemistry and physics classes, we have designed an inexpensive visible light absorption spectrophotometer. The spectrophotometer was constructed using LEGO blocks, a light emitting diode, optical elements (including a lens), a slide-mounted diffraction grating, and a…

  16. Dietary lead intakes for mother/child pairs and relevance to pharmacokinetic models.

    Science.gov (United States)

    Gulson, B L; Mahaffey, K R; Vidal, M; Jameson, C W; Law, A J; Mizon, K J; Smith, A J; Korsch, M J

    1997-12-01

    the absorption or uptake of lead from dietary sources is similar in adult females and children of the age in this study. In spite of lower bone lead and faster bone remodeling and recycling in children compared with adult females, we see no differences between the mothers and their children in overall contribution of tissue lead to blood lead. Results from this study suggest that fractional absorption of ingested lead by children 6-11 years of age is comparable with absorption patterns observed among adult females in the 29-37-year-old age range. Because pharmacokinetic models apply a 40-50% absorption even for 7-year-old children, further investigations on fractional absorption of ingested lead by young children are warranted. Further investigations are especially needed in younger children than those who were subjects in the current study, particularly children in the 1-3-year-old age range. In addition, the effect of nutritional status and patterns of food intake on children's lead absorption require investigation, particularly given the increased prevalence of marginal nutritional status among low-income populations that are at increased risk of elevated blood lead levels.

  17. Corneal endothelial cell density and morphology in low and moderate myopic Chinese eyes

    Directory of Open Access Journals (Sweden)

    Jane Mei Chun

    2013-08-01

    Full Text Available AIM: To describe and compare the corneal endothelial cell density and morphology in young, low and moderate myopic Chinese adults in Malaysian Chinese population.METHODS: Non-contact specular microscopy (Topcon SP3000P, Tokyo, Japan was performed in low (n=78; 21.22±1.51 years and moderate (n=78; 21.82±1.40 years myopic subjects. The mean of three consecutive measurements of endothelial cell density (MCD, coefficient of variation (CV in the cell size, and hexagonal appearance of the cell were obtained.RESULTS: In low myopic eyes the MCD was 3 063.0±176.2/mm2, the mean CV was 33.4±4.0% and the mean hexagonal appearance of the cell was 57.9±2.7%. In moderate myopic eyes the MCD was 2961.6±159.0/mm2, the mean CV was 33.9±3.6% and mean hexagonal appearance of the cell was 56.2±4.7%. There were statistically significant differences in MCD (PPCONCLUSION:The corneal endothelial cell layer in more myopic eyes tends to have less MCD and cell hexagonality compared to lower myopic eyes. Nevertheless, there is no significant difference in CV between low and moderate myopic eyes.

  18. In vivo analysis of supersaturation/precipitation/absorption behavior after oral administration of pioglitazone hydrochloride salt; determinant site of oral absorption.

    Science.gov (United States)

    Tanaka, Yusuke; Sugihara, Masahisa; Kawakami, Ayaka; Imai, So; Itou, Takafumi; Murase, Hirokazu; Saiki, Kazunori; Kasaoka, Satoshi; Yoshikawa, Hiroshi

    2017-08-30

    The purpose of this study was to evaluate in vivo supersaturation/precipitation/absorption behavior in the gastrointestinal (GI) tract based on the luminal concentration-time profiles after oral administration of pioglitazone (PG, a highly permeable lipophilic base) and its hydrochloride salt (PG-HCl) to rats. In the in vitro precipitation experiment in the classic closed system, while the supersaturation was stable in the simulated gastric condition, PG drastically precipitated in the simulated intestinal condition, particularly at a higher initial degree of supersaturation. Nonetheless, a drastic and moderate improvement in absorption was observed in vivo at a low and high dose of PG-HCl, respectively. Analysis based on the luminal concentration of PG after oral administration of PG-HCl at a low dose revealed that most of the dissolved PG emptied from the stomach was rapidly absorbed before its precipitation in the duodenum. At a high dose of PG-HCl, PG partly precipitated in the duodenum but was absorbed to some extent. Therefore, the extent of the absorption was mainly dependent on the duodenal precipitation behavior. Furthermore, a higher-than expected absorption after oral administration of PG-HCl from in vitro precipitation study may be due to the absorption process in the small intestine, which suppresses the precipitation by removal of the drug. This study successfully clarify the impact of the absorption process on the supersaturation/precipitation/absorption behavior and key absorption site for a salt formulation of a highly permeable lipophilic base based on the direct observation of in vivo luminal concentration. Our findings may be beneficial in developing an ideal physiologically based pharmacokinetic model and in vitro predictive dissolution tools and/or translating the in silico and in vitro data to the in vivo outcome. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Moderate Versus Light Pressure Massage Therapy Leads to Greater Weight Gain in Preterm Infants

    Science.gov (United States)

    Field, Tiffany; Diego, Miguel A.; Hernandez-Reif, Maria; Deeds, Osvelia; Figuereido, Barbara

    2007-01-01

    Sixty-eight preterm infants (M GA=3Owks.) were randomly assigned to a moderate or to a light pressure massage therapy group to receive 15 massages 3 times per day for 5 days. Behavior state, stress behaviors and heart rate were recorded for 15 minutes before and during the first 15-minute therapy session. Weight gain was recorded over the 5 day therapy period. The moderate versus light pressure massage group gained significantly more weight per day. During the behavior observations the moderate versus light pressure massage group showed significantly lower increases from the pre-session to the session recording on: 1) active sleep; 2) fussing; 3) crying; 4) movement; and 5) stress behavior (hiccupping). They also showed a smaller decrease in deep sleep, a greater decrease in heart rate and a greater increase in vagal tone. Thus, the moderate pressure massage therapy group appeared to be more relaxed and less aroused than the light pressure massage group which may have contributed to the greater weight gain of the moderate pressure massage therapy group. PMID:17138310

  20. Severe but Not Moderate Vitamin B12 Deficiency Impairs Lipid Profile, Induces Adiposity, and Leads to Adverse Gestational Outcome in Female C57BL/6 Mice.

    Science.gov (United States)

    Ghosh, Shampa; Sinha, Jitendra Kumar; Putcha, Uday Kumar; Raghunath, Manchala

    2016-01-01

    Vitamin B12 deficiency is widely prevalent in women of childbearing age, especially in developing countries. In the present study, through dietary restriction, we have established mouse models of severe and moderate vitamin B12 deficiencies to elucidate the impact on body composition, biochemical parameters, and reproductive performance. Female weanling C57BL/6 mice were fed for 4 weeks: (a) control AIN-76A diet, (b) vitamin B12-restricted AIN-76A diet with pectin as dietary fiber (severe deficiency group, as pectin inhibits vitamin B12 absorption), or (c) vitamin B12-restricted AIN-76A diet with cellulose as dietary fiber (moderate deficiency group as cellulose does not interfere with vitamin B12 absorption). After confirming deficiency, the mice were mated with male colony mice and maintained on their respective diets throughout pregnancy, lactation, and thereafter till 12 weeks. Severe vitamin B12 deficiency increased body fat% significantly, induced adiposity and altered lipid profile. Pregnant dams of both the deficient groups developed anemia. Severe vitamin B12 deficiency decreased the percentage of conception and litter size, pups were small-for-gestational-age and had significantly lower body weight at birth as well as weaning. Most of the offspring born to severely deficient dams died within 24 h of birth. Stress markers and adipocytokines were elevated in severe deficiency with concomitant decrease in antioxidant defense. The results show that severe but not moderate vitamin B12 restriction had profound impact on the physiology of C57BL/6 mice. Oxidative and corticosteroid stress, inflammation and poor antioxidant defense seem to be the probable underlying mechanisms mediating the deleterious effects.

  1. Severe but not moderate vitamin B12 deficiency impairs lipid profile, induces adiposity and leads to adverse gestational outcome in female C57BL/6 mice

    Directory of Open Access Journals (Sweden)

    Shampa eGhosh

    2016-01-01

    Full Text Available Vitamin B12 deficiency is widely prevalent in women of childbearing age especially in developing countries. In the present study, through dietary restriction, we have established mouse models of severe and moderate vitamin B12 deficiencies to elucidate the impact on body composition, biochemical parameters and reproductive performance. Female weanling C57BL/6 mice were fed for four weeks, (a control AIN-76A diet, (b vitamin B12 restricted AIN-76A diet with pectin as dietary fiber (severe deficiency group, as pectin inhibits vitamin B12 absorption or (c vitamin B12 restricted AIN-76A diet with cellulose as dietary fiber (moderate deficiency group as cellulose does not interfere with vitamin B12 absorption. After confirming deficiency, the mice were mated with male colony mice and maintained on their respective diets throughout pregnancy, lactation and thereafter till 12 weeks. Severe vitamin B12 deficiency increased body fat % significantly, induced adiposity and altered lipid profile. Pregnant dams of both the deficient groups developed anemia. Severe vitamin B12 deficiency decreased the percentage of conception and litter size, pups were small-for-gestational-age and had significantly lower body weight at birth as well as weaning. Most of the offspring born to severely deficient dams died within 24 hours of birth. Stress markers and adipocytokines were elevated in severe deficiency with concomitant decrease in antioxidant defense. The results show that severe but not moderate vitamin B12 restriction had profound impact on the physiology of C57BL/6 mice. Oxidative and corticosteroid stress, inflammation and poor antioxidant defense seem to be the probable underlying mechanisms mediating the deleterious effects.

  2. Who Gets to Lead the Multinational Team?

    DEFF Research Database (Denmark)

    Paunova, Minna

    2017-01-01

    of their core self-evaluations. A study of over 230 individuals from 46 nationalities working in 36 self-managing teams generally supports the expected main and moderation effects. Individual core self-evaluations enhance an otherwise weak effect of English proficiency, but compensate for low levels of national......This article examines the emergence of informal leadership in multinational teams. Building on and extending status characteristics theory, the article proposes and tests a model that describes how global inequalities reproduce in multinational teams, and accounts for who gets to lead these teams...

  3. Excitonic Effects in Methylammonium Lead Halide Perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Beard, Matthew C [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Chen, Xihan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lu, Haipeng [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Yang, Ye [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-05-01

    The exciton binding energy in methylammonium lead iodide (MAPbI3) is about 10 meV, around 1/3 of the available thermal energy (kBT ~ 26 meV) at room temperature. Thus, exciton populations are not stable at room temperature at moderate photoexcited carrier densities. However, excitonic resonances dominate the absorption onset. Furthermore, these resonances determine the transient absorbance and transient reflectance spectra. The exciton binding energy is a reflection of the Coulomb interaction energy between photoexcited electrons and holes. As such, it serves as a marker for the strength of electron/hole interactions and impacts a variety of phenomena, such as, absorption, radiative recombination, and Auger recombination. In this Perspective, we discuss the role of excitons and excitonic resonances in the optical properties of lead-halide perovskite semiconductors. Finally, we discuss how the strong light-matter interactions induce an optical stark effect splitting the doubly spin degenerate ground exciton states and are easily observed at room temperature.

  4. Safety and efficacy of low-dose isotretinoin in the treatment of moderate to severe acne vulgaris

    Directory of Open Access Journals (Sweden)

    Parinitha K Rao

    2014-01-01

    Full Text Available Background: Isotretinoin is indicated for moderate to severe cases of acne which are unresponsive to conventional therapy. The classical recommended dose is 0.5 to 1.0 mg/kg/day. As the side effects are dose related, low-dose isotretinoin therapy for acne is an attractive option; however, but little data exists on the safety and efficacy of this strategy. Materials and Methods: In this prospective, non-comparative study, 50 participants, both male and female, having moderate to severe acne vulgaris were enrolled and treated with isotretinoin at a dose of 20 mg/day (approximately 0.3-0.4 mg/kg/day, for a period of 3 months. Participants were evaluated by means of clinical and laboratory investigations before starting isotretinoin. Investigations were repeated at the end of the first and third months following completion of treatment, and participants were followed up for 6 months to look for any relapse. Results: At the end of the treatment, very good results were observed in 90% of participants. Cheilitis was the most common among the side effects observed and was seen in 98% of the participants. One participant developed vitiligo as a side effect, which is a new finding, and has not reported in literature before. Elevated serum lipid levels were observed in 6% of the participants, and relapse occurred in 4% of the participants over a 6 month follow up period. Conclusion: Three months of treatment with low-dose isotretinoin (20 mg/day was found to be effective in the treatment of moderate to severe acne vulgaris, with a low incidence of serious side effects. This dose also was more economical than the higher doses.

  5. The determination of aluminum, copper, iron, and lead in glycol formulations by atomic absorption spectroscopy

    Science.gov (United States)

    1977-01-01

    Initial screening tests and the results obtained in developing procedures to determine Al, Cu, Fe, and Pb in glycol formulations are described. Atomic absorption completion was selected for Cu, Fe and Pb, and after comparison with emission spectroscopy, was selected for Al also. Before completion, carbon, iron, and lead are extracted with diethyl dithio carbamate (DDC) into methyl isobutyl ketone (MIBK). Aluminum was also extracted into MIBK using 8-hydroxyquinoline as a chelating agent. As little as 0.02 mg/l carbon and 0.06 mg/l lead or iron may be determined in glycol formulations. As little as 0.3 mg/l aluminum may be determined.

  6. Enhanced absorption of graphene in the visible region by use of plasmonic nanostructures

    DEFF Research Database (Denmark)

    Hashemi, Mahdieh; Farzad, Mahmood Hosseini; Mortensen, N. Asger

    2013-01-01

    Low absorption of graphene in the visible range of the spectrum makes it difficult to uniquely benefit from this material in ultra-fast optoelectronic applications. We numerically propose to utilize patterned metallic nanostructures to increase light absorption in single-layer graphene. Simulation...... results show that excitation of surface plasmon resonances in the metallic nanostructures significantly enhances the local electromagnetic field near the graphene layer, therefore leading to a dramatic enhancement of the absorption in the graphene layer itself. Broadband high optical absorption can...

  7. Adenine radicals generated in alternating AT duplexes by direct absorption of low-energy UV radiation.

    Science.gov (United States)

    Banyasz, Akos; Ketola, Tiia; Martínez-Fernández, Lara; Improta, Roberto; Markovitsi, Dimitra

    2018-04-17

    There is increasing evidence that the direct absorption of photons with energies that are lower than the ionization potential of nucleobases may result in oxidative damage to DNA. The present work, which combines nanosecond transient absorption spectroscopy and quantum mechanical calculations, studies this process in alternating adenine-thymine duplexes (AT)n. We show that the one-photon ionization quantum yield of (AT)10 at 266 nm (4.66 eV) is (1.5 ± 0.3) × 10-3. According to our PCM/TD-DFT calculations carried out on model duplexes composed of two base pairs, (AT)1 and (TA)1, simultaneous base pairing and stacking does not induce important changes in the absorption spectra of the adenine radical cation and deprotonated radical. The adenine radicals, thus identified in the time-resolved spectra, disappear with a lifetime of 2.5 ms, giving rise to a reaction product that absorbs at 350 nm. In parallel, the fingerprint of reaction intermediates other than radicals, formed directly from singlet excited states and assigned to AT/TA dimers, is detected at shorter wavelengths. PCM/TD-DFT calculations are carried out to map the pathways leading to such species and to characterize their absorption spectra; we find that, in addition to the path leading to the well-known TA* photoproduct, an AT photo-dimerization path may be operative in duplexes.

  8. Effects of iron deficiency on the absorption and distribution of lead and cadmium in rats

    International Nuclear Information System (INIS)

    Ragan, H.A.

    1977-01-01

    In order to evaluate the effects of iron deficiency on the absorption of pollutant metals, an iron-deficient diet was fed to young rats until their tissue-iron stores were depleted. Prior to the development of anemia, the iron-deficient rats and littermate controls were administered an intragastric gavage of lead-210 or cadmium-109 and were killed 48 hr later. The body burden of lead was approximately 6 times greater, and that of cadmium approximately 7 times greater, in iron-deficient rats than in the controls. No consistent effects were observed on concentrations of serum total lipids or serum proteins nor on protein electrophoretic patterns in rats with a deficit in iron stores

  9. Initial occupational exposure to lead

    Energy Technology Data Exchange (ETDEWEB)

    Forni, A.; Cambiaghi, G.; Secchi, G.C.

    1976-01-01

    Serial chromosome and biochemical studies were carried out in 11 subjects before and during initial occupational exposure to moderate quantities of lead fumes in a storage battery plant. The rate of abnormal metaphases, mostly with chromatid and one-break chromosome aberrations, was approximately doubled after one month of work; it further increased after two months of work; remained in this range up to seven months of exposure; and then tended to decrease somewhat. Blood lead levels increased progressively in the first few months, then reached a steady state. Urinary lead and coproporphyrin levels increased sharply after one month of work, while urinary delta-aminolevulinic acid (ALA) levels increased moderately. The ALA dehydratase (ALAD) activity of red blood cells (RBCs) was reduced to almost 50 percent of the initial values after one month, decreased further in subsequent months, and remained decreased through the remainder of the study.

  10. Ammonia-lithium nitrate absorption chiller with an integrated low-pressure compression booster cycle for low driving temperatures

    International Nuclear Information System (INIS)

    Ventas, R.; Lecuona, A.; Zacarias, A.; Venegas, M.

    2010-01-01

    Single-effect absorption refrigeration hybridized with mechanical vapor compression in a vapor circuit is known as the absorption cycle with an integrated booster compressor. In this study, the compressor is located between the evaporator and the absorber. This paper presents a numerical model of this cycle with ammonia-lithium nitrate solution as the working pair. It is based on UA-ΔT lm models for separate regions of plate-type heat exchangers. The results are offered as a function of external circuit flow parameters. Different pressure ratios of the compressor were tested for a wide range of hot water driving temperatures (55-95 deg. C), showing that low values are more beneficial. This cycle allows for working at lower driving temperatures than the single-effect cycle, with low electricity consumption. At the same driving temperature, the capacity is augmented with an increased compressor pressure ratio, thus allowing for demand matching of the cooling. This cycle, operating with hot water at 67 deg. C with a pressure ratio of 2.0, has the capacity of a single-effect absorption cycle at 94 deg. C. The electrical COP was found to be higher than that in an ammonia vapor compression cycle for comprehensive working conditions.

  11. Estimation of lead and zinc in human hair using atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Kazi, S.; Kazi, T.G.; Kazi, G.H.

    1993-01-01

    Trace elements analysis in hair can be useful in studying the impact of environmental and dietary factors on human in general for lead and zinc content in hair. Samples of people of different age groups, sex with varied living habits of the individual living in different areas of Sind, urban as well as rural areas were of special interest to be studied to find correlation of socioeconomic factors and the presence of these elements in hair samples. The purpose of this study was to determine whether age, sex and physiological status and environmental pollution affect composition of hair. The method of sample preparation and use of atomic absorption techniques providing unequivocal and direct estimation of metals in ppm/ppb range to arrive upon conclusion. (author)

  12. An analysis of lead (Pb) from human hair samples (20-40 years of age) by atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Gelsano, Flordeliza K.; Timing, Laurie D.

    2003-01-01

    This analysis of lead from human hair samples in five different groups namely scavengers from Payatas Quezon City, tricycle drivers, car shop workers, paint factory workers, and students from Polytechnic University of the Philippines. The people from Nagcarlan, Laguna represented as a ''base-line value'' or as a control group. The method applied was acid digestion using HNO 3 and HClO 4 then the samples were subjected to atomic absorption spectrophotometer. In terms of lead found from hair, the scavengers from Payatas Q.C. obtained high exposure of lead among the samples that were tested. The result of the analysis of concentration of lead was expressed in mg/L. (Authors)

  13. Monte Carlo calculations on transmutation of trans-uranic nuclear waste isotopes using spallation neutrons difference of lead and graphite moderators

    CERN Document Server

    Hashemi-Nezhad, S R; Brandt, R; Krivopustov, M I; Kulakov, B A; Odoj, R; Sosnin, A N; Wan, J S; Westmeier, W

    2002-01-01

    Transmutation rates of sup 2 sup 3 sup 9 Pu and some minor actinides ( sup 2 sup 3 sup 7 Np, sup 2 sup 4 sup 1 Am, sup 2 sup 4 sup 5 Cm and sup 2 sup 4 sup 6 Cm), in two accelerator-driven systems (ADS) with lead or graphite moderating environments, were calculated using the LAHET code system. The ADS that were used had a large volume (approx 32 m sup 3) and contained no fissile material, except for a small amount of fissionable waste nuclei that existed in some cases. Calculations were performed at an incident proton energy of 1.5 GeV and the spallation target was lead. Also breeding rates of sup 2 sup 3 sup 9 Pu and sup 2 sup 3 sup 3 U as well as the transmutation rates of two long-lived fission products sup 9 sup 9 Tc and sup 1 sup 2 sup 9 I were calculated at different locations in the moderator. It is shown that an ADS with graphite moderator is a much more effective transmuter than that with lead moderator.

  14. Mental Health in Low-to-Moderate Risk Preterm, Low Birth Weight, and Small for Gestational Age Children at 4 to 5 Years: The Role of Early Maternal Parenting

    Science.gov (United States)

    Westrupp, Elizabeth M.; Mensah, Fiona K.; Giallo, Rebecca; Cooklin, Amanda; Nicholson, Jan M.

    2012-01-01

    Objectives: The majority of children born preterm, with low birth weight, or small for gestational age are born with low-to-moderate risk (LTM), yet most research focuses on the high-risk group. Little is known about whether children with LTM perinatal risk are at greater risk for mental health problems, or what the role of early maternal…

  15. [Iron absorption of the habitual diet in a population of low socioeconomic level].

    Science.gov (United States)

    Morón, C; Kremenchuzky, S; Passamai, M I; D'Andrea de Rivero, S; Pérez de Galíndez, G; Gerschcovich, C

    1985-06-01

    Iron absorption using the extrinsic double-tag method was determined in the habitual diet consumed by a group of 32 volunteers of both sexes, pertaining to the low socioeconomic strata. The diet was made up of bread, spaghetti, vegetables and meat, totalling 2,022 kcal, 65.0 g protein, 17.57 mg iron, and 28.75 mg ascorbic acid. According to our findings, men were found to be neither anemic nor iron-deficient. Among the women, however, 4.8% had anemia and 57.1% suffered from iron deficiency. The non-heme iron absorption was very low: 1.35% at breakfast, 3.29% at lunch, and 3.82% at dinner. Among those subjects found to be normal, the absorption was half the above figures, whereas among those with iron deficiency it was threefold, the differences being highly significant. The absorption of heme-iron for lunch and dinner was 17.53%. The iron deficient group had an absorption value four times greater than the normal group, the differences also being highly significant. The daily availability of non-heme, heme and total iron was 0.44, 1.13 and 1.57 mg, respectively. In the subjects who formed the normal group, total iron available was 1.14 mg, barely covering a man's daily requirements, but not those of a woman. In the iron-deficient group, it was 4.31 mg, that is, four times greater than in the normal group; while this value improves the balance, it does not prevent deficiency in women, with great blood losses. Bearing these results in mind, it is suggested that measures tending to improve dietary iron content and bio-availability, be enforced.

  16. In situ emulsification microextraction using a dicationic ionic liquid followed by magnetic assisted physisorption for determination of lead prior to micro-sampling flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Shokri, Masood; Beiraghi, Asadollah; Seidi, Shahram

    2015-01-01

    For the first time, a simple and efficient in situ emulsification microextraction method using a dicationic ionic liquid followed by magnetic assisted physisorption was presented to determine trace amounts of lead. In this method, 400 μL of 1.0 mol L −1 lithium bis (trifluoromethylsulfonyl) imide aqueous solution, Li[NTf 2 ], was added into the sample solution containing 100 μL of 1.0 mol L −1 1,3-(propyl-1,3-diyl) bis (3-methylimidazolium) chloride, [pbmim]Cl 2 , to form a water immiscible ionic liquid, [pbmim][NTf 2 ] 2 . This new in situ formed dicationic ionic liquid was applied as the acceptor phase to extract the lead-ammonium pyrrolidinedithiocarbamate (Pb-APDC) complexes from the sample solution. Subsequently, 30 mg of Fe 3 O 4 magnetic nanoparticles (MNPs) were added into the sample solution to collect the fine droplets of [pbmim][NTf 2 ] 2 , physisorptively. Finally, MNPs were eluted by acetonitrile, separated by an external magnetic field and the obtained eluent was subjected to micro-sampling flame atomic absorption spectrometry (FAAS) for further analysis. Comparing with other microextraction methods, no special devices and centrifugation step are required. Parameters influencing the extraction efficiency such as extraction time, pH, concentration of chelating agent, amount of MNPs and coexisting interferences were studied. Under the optimized conditions, this method showed high extraction recovery of 93% with low LOD of 0.7 μg L −1 . Good linearity was obtained in the range of 2.5–150 μg L −1 with determination coefficient (r 2 ) of 0.9921. Relative standard deviation (RSD%) for seven repeated measurements at the concentration of 10 μg L −1 was 4.1%. Finally, this method was successfully applied for determination of lead in some water and plant samples. - Highlights: • A dicationic ionic liquid was used as the extraction solvent, for the first time. • A simple and efficient in situ emulsification microextraction

  17. A moderate enthalpy and a low pollution load in healthy buildings

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    1998-01-01

    For the design of healthy buildings with a comfortable indoor environment, some general recommendations are provided. New research highlights the importance of controlling the enthalpy of indoor air at a moderate level, i.e., by controlling air temperature and relative humidity at a rather low...... level, still compatible with thermal comfort. A decrement of air temperature or humidity improves the perceived air quality and may decrease the required ventilation rate. A moderate air temperature and humidity plus individual control by radiation and conduction is recommended in order to decrease...

  18. Absorptive routines and international patent performance

    Directory of Open Access Journals (Sweden)

    Fernando E. García-Muiña

    2017-04-01

    We enrich the treatment of the absorptive capacity phases including the moderating effects between routines associated to the traditional potential-realized absorptive capacities. Taking into account external knowledge search strategies, the deeper external relationships, the better transference and appropriation of specific external knowledge. Nevertheless, when the moderating role of assimilation is included, cooperation agreements appear as the most efficient source of external knowledge. Finally, we show that technological tools let firms store and structure the information making easier its use for international patenting. This positive effect is reinforced in the presence of exploitation routines, since technological knowledge will better fit to the industry's key factors of success.

  19. Optimization of Brayton cycles for low-to-moderate grade thermal energy sources

    International Nuclear Information System (INIS)

    Rovira, Antonio; Muñoz-Antón, Javier; Montes, María José; Martínez-Val, José María

    2013-01-01

    Future electricity generation will involve low or moderate temperature technologies. In such a scenario, optimisation of thermodynamic cycles will be a key task. This work presents a systematic analysis to find the operating regime where Brayton cycles reach the highest efficiency, using real substances and given heat source and sink temperatures. Several configurations using fluids close to its critical point at the compressor inlet are considered. Irreversibility sources are carefully analysed, as well as the type of working fluid. The analysis is performed by means of a theoretical approach to obtain some trends, which are afterwards validated with real gases. Results show that the efficiency and the specific work improve if the compressor inlet is close to the critical point. Furthermore, these cycles are less sensitive to pressure drops and politropic efficiencies than those working with ideal gases. The above features are more evident when the ratio of heat source and heat sink temperatures is low. The selection of the gas becomes a fundamental issue in this quest. Critical temperature should be close to ambient temperature, low critical pressure is advisable and the R/c p factor measured at the ideal gas condition should be low to further enhance the efficiency. - Highlights: • Performance analysis of Brayton cycles with the compressor inlet close to the critical point. • Cycles are not very sensitive to pressure drops and isentropic efficiencies of the compressor. • Gas selection becomes important, regarding the critical pressure and temperature as well as the kind of fluid. • R/c p factor measured at the ideal gas condition should be as low as possible

  20. Methodology used to calculate moderator-system heat load at full power and during reactor transients in CANDU reactors

    International Nuclear Information System (INIS)

    Aydogdu, K.

    1998-01-01

    Nine components determine the moderator-system heat load during full-power operation and during a reactor power transient in a CANDU reactor. The components that contribute to the total moderator-system heat load at any time consist of the heat generated in the calandria tubes, guide tubes and reactivity mechanisms, moderator and reflector; the heat transferred from calandria shell, the inner tubesheets and the fuel channels; and the heat gained from moderator pumps and heat lost from piping. The contributions from each of these components will vary with time during a reactor transient. The sources of heat that arise from the deposition of nuclear energy can be divided into two categories, viz., a) the neutronic component (which is directly proportional to neutronic power), which includes neutron energy absorption, prompt-fission gamma absorption and capture gamma absorption; and b) the fission-product decay-gamma component, which also varies with time after initiation of the transient. An equation was derived to calculate transient heat loads to the moderator. The equation includes two independent variables that are the neutronic power and fission-product decay-gamma power fractions during the transient and a constant term that represents the heat gained from moderator pumps and heat lost from piping. The calculated heat load in the moderator during steady-state full-power operation for a CANDU 6 reactor was compared with available measurements from the Point Lepreau, Wolsong 1 and Gentilly-2 nuclear generating stations. The calculated and measured values were in reasonably good agreement. (author)

  1. Low morning serum cortisol levels in children with tonsillar hypertrophy and moderate-to-severe OSA.

    Science.gov (United States)

    Malakasioti, Georgia; Alexopoulos, Emmanouel I; Varlami, Vasiliki; Chaidas, Konstantinos; Liakos, Nikolaos; Gourgoulianis, Konstantinos; Kaditis, Athanasios G

    2013-09-01

    Hypertrophic tonsillar tissue in children with obstructive sleep apnea (OSA) has enhanced expression of glucocorticoid receptors, which may reflect low endogenous cortisol levels. We have evaluated the effect of the interaction between tonsillar hypertrophy and OSA severity on morning serum cortisol levels. Children with and without snoring underwent polysomnography, tonsillar size grading, and measurement of morning serum cortisol. Seventy children (2-13 years old) were recruited: 30 with moderate-to-severe OSA (apnea-hypopnea index [AHI] > 5 episodes/h), 26 with mild OSA (AHI > 1 and ≤ 5), and 14 controls (no snoring; AHI ≤ 1). Tonsillar hypertrophy was present in 56.7%, 53.8%, and 42.9% of participants in each group, respectively. Application of a general linear model demonstrated a significant effect of the interaction between severity of OSA and tonsillar hypertrophy on cortisol levels (P = 0.04), after adjustment for obesity, gender, and age. Among children with tonsillar hypertrophy, subjects with moderate-to-severe OSA (n = 17; AHI 14.7 ± 10.6), mild OSA (n = 14; AHI 2.3 ± 1.2), and control participants (n = 6; AHI 0.7 ± 0.2) were significantly different regarding cortisol levels (P = 0.02). Subjects with moderate-to-severe OSA had lower cortisol (16.9 ± 8.7 mcg/dL) than those with mild OSA (23.3 ± 4.2; P = 0.01) and those without OSA (controls) (23.6 ± 5.3 mcg/dL; P = 0.04). In contrast, children with normal-size tonsils and moderate-to-severe OSA, mild OSA, and controls did not differ in cortisol levels. Children with moderate-to-severe obstructive sleep apnea and the phenotype of hypertrophic tonsils have reduced morning serum cortisol levels and potentially decreased glucocorticoid inhibitory effects on tonsillar growth.

  2. An analysis of lead (Pb) from human hair samples (20-40 years of age) by atomic absorption spectrophotometry

    Energy Technology Data Exchange (ETDEWEB)

    Gelsano, Flordeliza K; Timing, Laurie D

    2003-02-17

    This analysis of lead from human hair samples in five different groups namely scavengers from Payatas Quezon City, tricycle drivers, car shop workers, paint factory workers, and students from Polytechnic University of the Philippines. The people from Nagcarlan, Laguna represented as a ''base-line value'' or as a control group. The method applied was acid digestion using HNO{sub 3} and HClO{sub 4} then the samples were subjected to atomic absorption spectrophotometer. In terms of lead found from hair, the scavengers from Payatas Q.C. obtained high exposure of lead among the samples that were tested. The result of the analysis of concentration of lead was expressed in mg/L. (Authors)

  3. Graphene oxide sheets immobilized polystyrene for column preconcentration and sensitive determination of lead by flame atomic absorption spectrometry.

    Science.gov (United States)

    Islam, Aminul; Ahmad, Hilal; Zaidi, Noushi; Kumar, Suneel

    2014-08-13

    A novel solid-phase extractant was synthesized by coupling graphene oxide (GO) on chloromethylated polystyrene through an ethylenediamine spacer unit to develop a column method for the preconcentration/separation of lead prior to its determination by flame atomic absorption spectrometry. It was characterized by Fourier transform infrared spectroscopy, far-infrared spectroscopy, thermogravimetric analysis/differential thermal analysis, scanning electron microscopy, energy-dispersive spectrometry, and transmission electron microscopy. The abundant oxygen-containing surface functional groups form a strong complex with lead, resulting in higher sorption capacity (227.92 mg g(-1)) than other nanosorbents used for sorption studies of the column method. Using the column procedure here is an alternative to the direct use of GO, which restricts irreversible aggregation of GO and its escape into the ecosystem, making it an environmentally sustainable method. The column method was optimized by varying experimental variables such as pH, flow rate for sorption/desorption, and elution condition and was observed to exhibit a high preconcentration factor (400) with a low preconcentration limit (2.5 ppb) and a high degree of tolerance for matrix ions. The accuracy of the proposed method was verified by determining the Pb content in the standard reference materials and by recovery experiments. The method showed good precision with a relative standard deviation <5%. The proposed method was successfully applied for the determination of lead in tap water, electroplating wastewater, river water, and food samples after preconcentration.

  4. Anger as a moderator of safer sex motivation among low-income urban women.

    Science.gov (United States)

    Schroder, Kerstin E E; Carey, Michael P

    2005-10-01

    Theoretical models suggest that both HIV knowledge and HIV risk perception inform rational decision making and, thus, predict safer sex motivation and behavior. However, the amount of variance explained by knowledge and risk perception is typically small. In this cross-sectional study, we investigated whether the predictive power of HIV knowledge and HIV risk perception on safer sex motivation is affected by trait anger. We hypothesized that anger may disrupt rational decision making, distorting the effects of both HIV knowledge and risk perception on safer sex intentions. Data from 232 low-income, urban women at risk for HIV infection were used to test a path model with past sexual risk behavior, HIV knowledge, and HIV risk perception as predictors of safer sex intentions. Moderator effects of anger on safer sex intentions were tested by simultaneous group comparisons between high-anger and low-anger women (median split). The theoretically expected "rational pattern" was found among low-anger women only, including (a) a positive effect of knowledge on safer sex intentions, and (b) buffer (inhibitor) effects of HIV knowledge and HIV risk perception on the negative path leading from past risk behavior to safer sex intentions. Among high-anger women, an "irrational pattern" emerged, with no effects of HIV knowledge and negative effects of both past risk behavior and HIV risk perception on safer sex intentions. In sum, the results suggest that rational knowledge- and risk-based decisions regarding safer sex may be limited to low-anger women.

  5. Effects of hiking at moderate and low altitude on cardiovascular parameters in male patients with metabolic syndrome: Austrian Moderate Altitude Study.

    Science.gov (United States)

    Neumayr, Günther; Fries, Dietmar; Mittermayer, Markus; Humpeler, Egon; Klingler, Anton; Schobersberger, Wolfgang; Spiesberger, Reinhard; Pokan, Rochus; Schmid, Peter; Berent, Robert

    2014-09-01

    Physical activity is a cornerstone in therapy for patients with metabolic syndrome. Walking and hiking in a mountain scenery represents an ideal approach to make them move. The Austrian Moderate Altitude Study (AMAS) 2000 main study is a randomized controlled trial to investigate the cardiovascular effects of hiking at moderate altitude on patients with metabolic syndrome compared with a control group at low altitude, to assess a potential altitude-specific effect. Seventy-one male patients with metabolic syndrome were randomly assigned to a moderate altitude group (at 1700 m), with 36 participants, or to a low altitude group (at 200 m), with 35 participants. The 3-week vacation program included 12 hiking tours (4 per week, average duration 2.5 hours, intensity 55% to 65% of heart rate maximum). Physical parameters, performance capacity, 24-hour blood pressure, and heart rate profiles were obtained before, during, and after the stay. In both groups, we found a significant mean weight loss of -3.13 kg; changes in performance capacity were minor. Systolic, diastolic, and mean arterial pressures and circadian heart rate profiles were significantly reduced in both groups, with no differences between them. Consequently, the pressure-rate product was reduced as well. All study participants tolerated the vacation well without any adverse events. A 3-week hiking vacation at moderate or low altitude is safe for patients with metabolic syndrome and provides several improvements in their cardiovascular parameters. The cardiovascular benefits achieved are more likely to be the result of regular physical activity than the altitude-specific effect of a mountain environment. Copyright © 2014 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  6. Lead in teeth from lead-dosed goats: Microdistribution and relationship to the cumulative lead dose

    International Nuclear Information System (INIS)

    Bellis, David J.; Hetter, Katherine M.; Jones, Joseph; Amarasiriwardena, Dula; Parsons, Patrick J.

    2008-01-01

    Teeth are commonly used as a biomarker of long-term lead exposure. There appear to be few data, however, on the content or distribution of lead in teeth where data on specific lead intake (dose) are also available. This study describes the analysis of a convenience sample of teeth from animals that were dosed with lead for other purposes, i.e., a proficiency testing program for blood lead. Lead concentration of whole teeth obtained from 23 animals, as determined by atomic absorption spectrometry, varied from 0.6 to 80 μg g -1 . Linear regression of whole tooth lead (μg g -1 ) on the cumulative lead dose received by the animal (g) yielded a slope of 1.2, with r 2 =0.647 (p -1 , were found in circumpulpal dentine. Linear regression of circumpulpal lead (μg g -1 ) on cumulative lead dose (g) yielded a slope of 23 with r 2 =0.961 (p=0.0001). The data indicated that whole tooth lead, and especially circumpulpal lead, of dosed goats increased linearly with cumulative lead exposure. These data suggest that circumpulpal dentine is a better biomarker of cumulative lead exposure than is whole tooth lead, at least for lead-dosed goats

  7. Determination of tellurium in lead and lead alloy using flow injection-hydride generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Mesko, Marcia F.; Pozebon, Dirce; Flores, Erico M.M.; Dressler, Valderi L.

    2004-01-01

    A method based on flow injection-hydride generation atomic absorption spectrometry (FI-HG AAS) for the determination of trace amount of Te in lead and lead alloy is described. A flow injection system (FI) and related analytical parameters as well as Te determination and interference caused by Pb, Bi and Ag on Te were investigated. The Pb interference could be overcome by using a small sample volume, while the Bi interference could be overcome by thiourea. However, it was not possible to minimise the interference caused by Ag on Te. The optimised conditions for Te determination in the analysed samples were: 6 mol l -1 HCl as sample carrier solution, 0.75% (m/v) sodium tetrahydroborate as Te reductant, 40 μl of sample solution, and 200 ml min -1 Ar flow rate as carrier gas. The limit of quantification (LOQ) was 1.0 μg g -1 Te (using 250 mg of sample in 50 ml final solution), the limit of detection (LOD) was 2.5 μg l -1 and the relative standard deviation (RSD) was 6% for five consecutive measurements of sample solution. The standard addition calibration method was used. Relatively high sample throughput (ca. 45 sample runs can be performed in a working hour), reduced sample manipulation since matrix separation is not necessary, and minor waste generation are the main advantages of the proposed method for Te determination by FI-HG AAS

  8. Radiogenic lead with dominant content of {sup 208}Pb: New coolant and neutron moderator for innovative nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Shmelev, A. N.; Kulikov, G. G.; Kryuchkov, E. F.; Apse, V. A.; Kulikov, E. G. [National Research Nuclear Univ. MEPhI, Kashirskoe shosse, 31, 115409, Moscow (Russian Federation)

    2012-07-01

    The advantages of radiogenic lead with dominant content of {sup 208}Pb as a reactor coolant with respect to natural lead are caused by unique nuclear properties of {sup 208}Pb which is a double-magic nucleus with closed proton and neutron shells. This results in significantly lower micro cross section and resonance integral of radiative neutron capture by {sup 208}Pb than those for numerous light neutron moderators. The extremely weak ability of {sup 208}Pb to absorb neutrons results in the following effects. Firstly, neutron moderating factor (ratio of scattering to capture cross sections) is larger than that for graphite and light water. Secondly, age and diffusion length of thermal neutrons are larger than those for graphite, light and heavy water. Thirdly, neutron lifetime in {sup 208}Pb is comparable with that for graphite, beryllium and heavy water what could be important for safe reactor operation. The paper presents some results obtained in neutronics and thermal-hydraulics evaluations of the benefits from the use of radiogenic lead with dominant content of {sup 208}Pb instead of natural lead as a coolant of fast breeder reactors. The paper demonstrates that substitution of radiogenic lead for natural lead can offer the following benefits for operation of fast breeder reactors. Firstly, improvement of the reactor safety thanks to the better values of coolant temperature reactivity coefficient and, secondly, improvement of some thermal-hydraulic reactor parameters. Radiogenic lead can be extracted from thorium sludge without isotope separation as {sup 208}Pb is a final isotope in the decay chain of {sup 232}Th. (authors)

  9. Radioactive lead studies in the human

    International Nuclear Information System (INIS)

    Blake, K.C.H.

    1980-08-01

    The differing susceptibility of individuals to the toxic effects of chronic lead exposure has never been fully understood. As the major intake of lead in the human is from food and beverages, any variation between individuals of the quantity of lead absorbed from the gut, and of the distribution and excretion of this lead, may account for the differences in individual susceptibility. The food and beverages themselves may have an influence, and to investigate their effects on absorption, distribution and excretion of lead, experiments were performed on normal subjects using a short lived radionuclide of lead, 203 Pb, and instruments generally available in Nuclear Medicine. Lead absorption between different individuals showed a wide variation when 203 Pb was taken as a single dose between meals. Minerals were found to be mainly responsible for affecting absorption when one subject ingested 203 Pb in control meals from which one dietary constituent at a time was omitted. Calcium and phosphorous were found to reduce the absorption of 203 Pb to approximately the same level as that produced by the total minerals. Calcium reduced absorption more than phosphorous when these minerals were ingested separately with 203 Pb. It was concluded that the calcium and phosphorous in the diet could influence susceptibility to lead toxicity through changes in the absorption of food and water lead and in the distribution of lead in the body. The results suggest that the prophylactic effect of calcium on lead absorption should be recognised and applied in this time of increased environmental levels of lead

  10. Mutacins and bacteriocins like genes in Streptococcus mutans isolated from participants with high, moderate, and low salivary count.

    Science.gov (United States)

    Soto, Carolina; Padilla, Carlos; Lobos, Olga

    2017-02-01

    To detect S. mutans producers of mutacins and bacteriocins like substances (BLIS) from saliva of participants with low, moderate, and high salivary counts. 123 strains of S. mutans were obtained from participants with low, moderate, and high salivary counts (age 18 and 20 years old) and their antibacterial capacity analyzed. By using PCR amplification, the expression levels of mutacins and BLIS genes were studied (expressed in arbitrary units/ml) in all three levels. S. mutans strains from participants with low salivary counts show high production of mutacins (63%). In contrast, participants with moderate and high salivary counts depict relatively low levels of mutacins (22 and 15%, respectively). Moreover, participants with low salivary counts showed high expression levels of genes encoding mutacins, a result that correlates with the strong antimicrobial activity of the group. Participants with moderate and high salivary counts however depict low expression levels of mutacin related genes, and little antimicrobial activity. No BLIS were detected in any of the groups studied. S. mutans isolated from the saliva of participants with low bacterial counts have significant antibacterial capacity compared to that of participants with moderate and high salivary counts. The superior lethality of S. mutans in participants with low salivary counts is likely due to the augmented expression of mutacin- related genes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Fabrication of Porous Ceramic-Geopolymer Based Material to Improve Water Absorption and Retention in Construction Materials: A Review

    Science.gov (United States)

    Jamil, N. H.; Ibrahim, W. M. A. W.; Abdullah, M. M. A. B.; Sandu, A. V.; Tahir, M. F. M.

    2017-06-01

    Porous ceramic nowadays has been investigated for a variety of its application such as filters, lightweight structural component and others due to their specific properties such as high surface area, stability and permeability. Besides, it has the properties of low thermal conductivity. Various formation techniques making these porous ceramic properties can be tailored or further fine-tuned to obtain the optimum characteristic. Porous materials also one of the good candidate for absorption properties. Conventional construction materials are not design to have good water absorption and retention that lead to the poor performance on these criteria. Temperature is a major driving force for moisture movement and influences sorption characteristics of many constructions materials. The effect of elevated temperatures on the water absorption coefficient and retention remain as critical issue that need to be investigated. Therefore, this paper will review the process parameters in fabricating porous ceramic for absorption properties.

  12. Broadband solar absorption enhancement via periodic nanostructuring of electrodes.

    KAUST Repository

    Adachi, Michael M; Labelle, André J; Thon, Susanna M; Lan, Xinzheng; Hoogland, Sjoerd; Sargent, Edward H

    2013-01-01

    Solution processed colloidal quantum dot (CQD) solar cells have great potential for large area low-cost photovoltaics. However, light utilization remains low mainly due to the tradeoff between small carrier transport lengths and longer infrared photon absorption lengths. Here, we demonstrate a bottom-illuminated periodic nanostructured CQD solar cell that enhances broadband absorption without compromising charge extraction efficiency of the device. We use finite difference time domain (FDTD) simulations to study the nanostructure for implementation in a realistic device and then build proof-of-concept nanostructured solar cells, which exhibit a broadband absorption enhancement over the wavelength range of λ = 600 to 1,100 nm, leading to a 31% improvement in overall short-circuit current density compared to a planar device containing an approximately equal volume of active material. Remarkably, the improved current density is achieved using a light-absorber volume less than half that typically used in the best planar devices.

  13. Broadband solar absorption enhancement via periodic nanostructuring of electrodes.

    KAUST Repository

    Adachi, Michael M

    2013-10-14

    Solution processed colloidal quantum dot (CQD) solar cells have great potential for large area low-cost photovoltaics. However, light utilization remains low mainly due to the tradeoff between small carrier transport lengths and longer infrared photon absorption lengths. Here, we demonstrate a bottom-illuminated periodic nanostructured CQD solar cell that enhances broadband absorption without compromising charge extraction efficiency of the device. We use finite difference time domain (FDTD) simulations to study the nanostructure for implementation in a realistic device and then build proof-of-concept nanostructured solar cells, which exhibit a broadband absorption enhancement over the wavelength range of λ = 600 to 1,100 nm, leading to a 31% improvement in overall short-circuit current density compared to a planar device containing an approximately equal volume of active material. Remarkably, the improved current density is achieved using a light-absorber volume less than half that typically used in the best planar devices.

  14. Adverse health effects of lead exposure on children and exploration to internal lead indicator

    International Nuclear Information System (INIS)

    Wang, Q.; Zhao, H.H.; Chen, J.W.; Gu, K.D.; Zhang, Y.Z.; Zhu, Y.X.; Zhou, Y.K.; Ye, L.X.

    2009-01-01

    Our research on adverse effects of lead exposures on physical and neurobehavioral health of children aged 6-12 years in 4 villages, labeled as K, M, L, and X, in rural China, was reported in this article. Lead in blood (PbB), urine (PbU), hairs (PbH), and nails (PbN) were measured by graphite furnace atomic absorption spectrometry. Abbreviated Symptom Questionnaire of Conner's instruments and Revised Raven's Standard Progressive Matrices were applied to evaluate childhood attention deficit/hyperactivity disorders (ADHD) and intelligences. Geometric means (SD) of PbB, PbU, PbH and PbN concentrations were 71.2 μg/L (1.56), 11.7 μg/g (1.75), 12.5 μg/g (2.82), and 25.3 μg/g (2.79), respectively. 54 (17.0%) children had PbB levels of ≥ 100 μg/L. Boys, the 6-10 years old, and living in village K were 2.11, 2.48, and 9.16 times, respectively, more likely to be poisoned by lead than girls, aged 11-12 years, and residing in X. 18 (5.7%) and 37 (11.7%) subjects had ADHD and mental retardations, respectively. Inverse relationships between intelligences and natural log transformed PbU and PbH levels were observed with respective odds ratios (95%CI) of 1.79 (1.00-3.22) and 1.46 (1.06-2.03) or 1.28 (1.04-1.58) and 1.73 (1.18-2.52) by binary or ordinal logistic regression modeling. ADHD prevalence was different by gender and age of subjects. PbU, PbH, and PbN related to PbB positively with respective correlation coefficients of 0.530, 0.477, and 0.181. Receiver operating characteristic (ROC) curves of the three measurements reveled areas under curves (AUCs) being 0.829, 0.758, and 0.687, respectively. In conclusion, children had moderate levels of lead exposures in this rural area. Intelligence declines were associated with internal lead levels among children. ROC analysis suggests PbU an internal lead indicator close to PbB.

  15. Adverse health effects of lead exposure on children and exploration to internal lead indicator

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Q.; Zhao, H.H. [Department of Epidemiology and Biostatistics, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030 (China); Chen, J.W.; Gu, K.D.; Zhang, Y.Z.; Zhu, Y.X.; Zhou, Y.K. [Minitry of Environmental Protection Key Lab of Environment, Wuhan 430030 (China); Ye, L.X., E-mail: yelx2004@163.com [Department of Epidemiology and Biostatistics, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030 (China)

    2009-11-15

    Our research on adverse effects of lead exposures on physical and neurobehavioral health of children aged 6-12 years in 4 villages, labeled as K, M, L, and X, in rural China, was reported in this article. Lead in blood (PbB), urine (PbU), hairs (PbH), and nails (PbN) were measured by graphite furnace atomic absorption spectrometry. Abbreviated Symptom Questionnaire of Conner's instruments and Revised Raven's Standard Progressive Matrices were applied to evaluate childhood attention deficit/hyperactivity disorders (ADHD) and intelligences. Geometric means (SD) of PbB, PbU, PbH and PbN concentrations were 71.2 {mu}g/L (1.56), 11.7 {mu}g/g (1.75), 12.5 {mu}g/g (2.82), and 25.3 {mu}g/g (2.79), respectively. 54 (17.0%) children had PbB levels of {>=} 100 {mu}g/L. Boys, the 6-10 years old, and living in village K were 2.11, 2.48, and 9.16 times, respectively, more likely to be poisoned by lead than girls, aged 11-12 years, and residing in X. 18 (5.7%) and 37 (11.7%) subjects had ADHD and mental retardations, respectively. Inverse relationships between intelligences and natural log transformed PbU and PbH levels were observed with respective odds ratios (95%CI) of 1.79 (1.00-3.22) and 1.46 (1.06-2.03) or 1.28 (1.04-1.58) and 1.73 (1.18-2.52) by binary or ordinal logistic regression modeling. ADHD prevalence was different by gender and age of subjects. PbU, PbH, and PbN related to PbB positively with respective correlation coefficients of 0.530, 0.477, and 0.181. Receiver operating characteristic (ROC) curves of the three measurements reveled areas under curves (AUCs) being 0.829, 0.758, and 0.687, respectively. In conclusion, children had moderate levels of lead exposures in this rural area. Intelligence declines were associated with internal lead levels among children. ROC analysis suggests PbU an internal lead indicator close to PbB.

  16. Adverse health effects of lead exposure on children and exploration to internal lead indicator

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Q.; Zhao, H. H. [Department of Epidemiology and Biostatistics, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030 (China); Chen, J. W.; Gu, K. D.; Zhang, Y. Z.; Zhu, Y. X.; Zhou, Y. K. [Minitry of Environmental Protection Key Lab of Environment, Wuhan 430030 (China); Ye, L.X., E-mail: yelx2004@163.com [Department of Epidemiology and Biostatistics, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030 (China)

    2009-11-15

    Our research on adverse effects of lead exposures on physical and neurobehavioral health of children aged 6-12 years in 4 villages, labeled as K, M, L, and X, in rural China, was reported in this article. Lead in blood (PbB), urine (PbU), hairs (PbH), and nails (PbN) were measured by graphite furnace atomic absorption spectrometry. Abbreviated Symptom Questionnaire of Conner's instruments and Revised Raven's Standard Progressive Matrices were applied to evaluate childhood attention deficit/hyperactivity disorders (ADHD) and intelligences. Geometric means (SD) of PbB, PbU, PbH and PbN concentrations were 71.2 {mu}g/L (1.56), 11.7 {mu}g/g (1.75), 12.5 {mu}g/g (2.82), and 25.3 {mu}g/g (2.79), respectively. 54 (17.0%) children had PbB levels of {>=} 100 {mu}g/L. Boys, the 6-10 years old, and living in village K were 2.11, 2.48, and 9.16 times, respectively, more likely to be poisoned by lead than girls, aged 11-12 years, and residing in X. 18 (5.7%) and 37 (11.7%) subjects had ADHD and mental retardations, respectively. Inverse relationships between intelligences and natural log transformed PbU and PbH levels were observed with respective odds ratios (95%CI) of 1.79 (1.00-3.22) and 1.46 (1.06-2.03) or 1.28 (1.04-1.58) and 1.73 (1.18-2.52) by binary or ordinal logistic regression modeling. ADHD prevalence was different by gender and age of subjects. PbU, PbH, and PbN related to PbB positively with respective correlation coefficients of 0.530, 0.477, and 0.181. Receiver operating characteristic (ROC) curves of the three measurements reveled areas under curves (AUCs) being 0.829, 0.758, and 0.687, respectively. In conclusion, children had moderate levels of lead exposures in this rural area. Intelligence declines were associated with internal lead levels among children. ROC analysis suggests PbU an internal lead indicator close to PbB.

  17. Myelin basic protein in brains of rats with low dose lead encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Sundstroem, R; Karlsson, B

    1987-02-01

    In the present study control rats and lead exposed rats which did not have any retardation of growth were examined by radioimmunological assay of myelin basic protein (MBP) of homogenates of cerebrum and cerebellum at 30, 60 and 120 days of age. Lead was administered on postnatal days 1-15 by daily intraperitoneal injections of 10 mg lead nitrate/kg body weight. This lead dose results in light microscopically discernible hemorrhagic encephalopathy in the cerebellum of 15-day old rats, but does not induce growth retardation. The controls were injected with vehicle only. The amount of lead in the blood and brain homogenates of lead-exposed and control rats 15-200 days old was estimated by atomic absorption spectrophotometry. Significant differences between the lead-exposed and control rats were not found in the cerebral or cerebellar content of MBP. Considering the results of previous investigations, the findings do not exclude a hypo-myelinating effect of lead, but they suggest that exposure to lead without concomitant malnutrition does not cause hypo-myelination in the cerebrum and cerebellum of the developing rat.

  18. Effect of bacterial or porcine lipase with low- or high-fat diets on nutrient absorption in pancreatic-insufficient dogs.

    Science.gov (United States)

    Suzuki, A; Mizumoto, A; Rerknimitr, R; Sarr, M G; DiMango, E P

    1999-02-01

    Treatment of human exocrine pancreatic insufficiency is suboptimal. This study assessed the effects of bacterial lipase, porcine lipase, and diets on carbohydrate, fat, and protein absorption in pancreatic-insufficient dogs. Dogs were given bacterial or porcine lipase and 3 diets: a 48% carbohydrate, 27% fat, and 25% protein standard diet; a high-carbohydrate, low-fat, and low-protein diet; or a low-carbohydrate, high-fat, and high-protein diet (66%/18%/16% and 21%/43%/36% calories). With the standard diet, coefficient of fat absorption increased dose-dependently with both lipases (P vs. low-fat and -protein diet). There were no interactions among carbohydrate, fat, and protein absorption. Correcting steatorrhea requires 75 times more porcine than bacterial lipase (18 vs. 240 mg). High-fat and high-protein diets optimize fat absorption with both enzymes. High-fat diets with bacterial or porcine lipase should be evaluated in humans with pancreatic steatorrhea.

  19. Chronic exposure to low-levels of lead in the rat: biochemical and behavioural changes

    International Nuclear Information System (INIS)

    Rossouw, J.

    1987-01-01

    The prevalence of lead in the environment is a cause of continuing toxicology concern and there have been numerous human and animal studies to examine more thoroughly the possible consequences of exposure to this ecotoxicant. Because lead is highly toxic to the developing central nervous system, increasing concern over the rise in the lead content in the environment has been expressed. These concerns seem appropriate since more recent clinical studies have shown that prolonged exposure of children to so called 'subclinical' concentrations of lead may be associated with behavioural disorders, learning disabilities and mental retardation. Moreover, animal studies have shown that chronic perinatal low-level lead exposure elicits alterations in both learned and spontaneous behavioural patterns in the absence of typical outward signs of lead-induced neurological toxicity. No study however could relate behavioural changes to specific alterations in neurochemisty. The aim of this study was therefore to expose rats, in different stages of their development, to low-levels of lead in order to induce behavioural disorders and correlate latter with possible neurochemical changes. In accordance with the general aims of the study, the structuring of the thesis is as follows: (a) a discussion of the neurotransmitters in the brain in order to describe the different systems which have been investigated; (b) a review of appropriate literature regarding the kinetics, toxodynamics and neurotoxicity of lead and (c) a summary of the methods employed in the study. The following results are presented: (d) the effects of lead treatment on physical development of the rats; (e) the induction of behavioural supersensitivity and (f) the effects lead has on central receptors

  20. Anger as a Moderator of Safer Sex Motivation among Low Income Urban Women

    Science.gov (United States)

    Carey, Michael P.

    2005-01-01

    Theoretical models suggest that both HIV knowledge and HIV risk perception inform rational decision-making and, thus, predict safer sex motivation and behavior. However, the amount of variance explained by knowledge and risk perception is typically small. In this cross-sectional study, we investigated whether the predictive power of HIV knowledge and HIV risk perception on safer sex motivation is affected by trait anger. We hypothesized that anger may disrupt rational-decision making, distorting the effects of both HIV knowledge and risk perception on safer sex intentions. Data from 232 low-income, urban women at risk for HIV infection were used to test a path model with past sexual risk behavior, HIV knowledge, and HIV risk perception as predictors of safer sex intentions. Moderator effects of anger on safer sex intentions were tested by simultaneous group comparisons between high-anger and low-anger women (median-split). The theoretically expected “rational pattern” was found among low-anger women only, including (a) a positive effect of knowledge on safer sex intentions, and (b) buffer (inhibitor) effects of HIV knowledge and HIV risk perception on the negative path leading from past risk behavior to safer sex intentions. Among high-anger women, an “irrational pattern” emerged, with no effects of HIV knowledge and negative effects of both past risk behavior and HIV risk perception on safer sex intentions. In sum, the results suggest that rational knowledge and risk-based decisions regarding safer sex may be limited to low-anger women. PMID:16247592

  1. Lead toxicity on hematological parameters in workers with occupational exposure to lead

    International Nuclear Information System (INIS)

    Dursun, N.; Koese, K.

    1998-01-01

    The effects of lead on hematological parameters were studied in lead exposed male workers occupied for 17.84+-4.22 years in a metal powder producing factory in Kayseri, Turkey and control male workers in same city. Blood lead and plasma zinc levels were measured by Atomic Absorption Spectrophotometry (AAS) and hematological parameters by Culture Counter S. The lead exposure workers had higher lead levels (13.81+- 9.21 mug/dl) as compared to control subjects (2.37+-0.10 mug/dl). No difference was observed in the plasma zinc levels of both groups. As indices of lead exposure, red blood cell (RBC) counts, hemoglobin (Hb), and hematocrit (Hct) values significantly decreased. Mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and mean corpuscular haemoglobin concentration (MCHC) significantly increased except MCV. There was also an increase in MCV, but it was not significant. (author)

  2. The effects of low to moderate prenatal alcohol exposure in early pregnancy on IQ in 5-year-old children

    DEFF Research Database (Denmark)

    Eriksen, H-L Falgreen; Mortensen, Erik Lykke; Kilburn, Tina R.

    2012-01-01

    Please cite this paper as: Falgreen Eriksen H, Mortensen E, Kilburn T, Underbjerg M, Bertrand J, Støvring H, Wimberley T, Grove J, Kesmodel U. The effects of low to moderate prenatal alcohol exposure in early pregnancy on IQ in 5-year-old children. BJOG 2012;119:1191-1200. Objective To examine...... the effects of low to moderate maternal alcohol consumption during early pregnancy on children's intelligence (IQ) at age 5 years. Design Prospective follow-up study. Setting Neuropsychological testing in four Danish cities 2003-2008. Population A cohort of 1628 women and their children sampled from...... the Danish National Birth Cohort. Methods Participants were sampled based on maternal alcohol consumption during pregnancy. At 5 years of age, children were tested with the Wechsler Preschool and Primary Scale of Intelligence-Revised (WPPSI-R). Parental education, maternal IQ, maternal smoking in pregnancy...

  3. Scattering and absorption measurements of cervical tissues measures using low cost multi-spectral imaging

    Science.gov (United States)

    Bernat, Amir S.; Bar-Am, Kfir; Cataldo, Leigh; Bolton, Frank J.; Kahn, Bruce S.; Levitz, David

    2018-02-01

    Cervical cancer is a leading cause of death for women in low resource settings. In order to better detect cervical dysplasia, a low cost multi-spectral colposcope was developed utilizing low costs LEDs and an area scan camera. The device is capable of both traditional colposcopic imaging and multi-spectral image capture. Following initial bench testing, the device was deployed to a gynecology clinic where it was used to image patients in a colposcopy setting. Both traditional colposcopic images and spectral data from patients were uploaded to a cloud server for remote analysis. Multi-spectral imaging ( 30 second capture) took place before any clinical procedure; the standard of care was followed thereafter. If acetic acid was used in the standard of care, a post-acetowhitening colposcopic image was also captured. In analyzing the data, normal and abnormal regions were identified in the colposcopic images by an expert clinician. Spectral data were fit to a theoretical model based on diffusion theory, yielding information on scattering and absorption parameters. Data were grouped according to clinician labeling of the tissue, as well as any additional clinical test results available (Pap, HPV, biopsy). Altogether, N=20 patients were imaged in this study, with 9 of them abnormal. In comparing normal and abnormal regions of interest from patients, substantial differences were measured in blood content, while differences in oxygen saturation parameters were more subtle. These results suggest that optical measurements made using low cost spectral imaging systems can distinguish between normal and pathological tissues.

  4. Absorption of acoustic waves by sunspots. II - Resonance absorption in axisymmetric fibril models

    Science.gov (United States)

    Rosenthal, C. S.

    1992-01-01

    Analytical calculations of acoustic waves scattered by sunspots which concentrate on the absorption at the magnetohydrodynamic Alfven resonance are extended to the case of a flux-tube embedded in a uniform atmosphere. The model is based on a flux-tubes of varying radius that are highly structured, translationally invariant, and axisymmetric. The absorbed fractional energy is determined for different flux-densities and subphotospheric locations with attention given to the effects of twist. When the flux is highly concentrated into annuli efficient absorption is possible even when the mean magnetic flux density is low. The model demonstrates low absorption at low azimuthal orders even in the presence of twist which generally increases the range of wave numbers over which efficient absorption can occur. Resonance absorption is concluded to be an efficient mechanism in monolithic sunspots, fibril sunspots, and plage fields.

  5. Job Resources and Work Engagement: Optimism as Moderator Among Finnish Managers

    Directory of Open Access Journals (Sweden)

    Stela Rumenova Salminen

    2014-05-01

    Full Text Available The aim of the present study was to investigate the moderating role of optimism in the relationship between job resources (organizational climate, job control and work engagement among Finnish young managers ('N' = 747. Hierarchical regression analyses showed that both job resources and optimism exerted a positive effect on work engagement and its three dimensions of vigor, dedication, and absorption. The moderation results showed that optimism can diminish the negative impact of low job resources on work engagement. These findings provide evidence to the importance of including personal resources in future research conducted on motivational process. Additionally, these findings provide significant suggestions for the utilization of these resources in organizational practice too, i.e., in staff recruitment, retention and development.

  6. Intestinal absorption of copper: influence of carbohydrates.

    Science.gov (United States)

    Wapnir, R A; Balkman, C

    1992-02-01

    Macronutrients can modulate the intestinal absorption of trace elements by binding the metal or altering mucosal function. We investigated whether certain simple and complex carbohydrates modify copper (Cu) absorption, using an in vivo perfusion technique in the rat. Corn syrup solids, which contain a mixture of glucose polymers of diverse length, added at either 20 or 50 mosm/kg enhanced Cu absorption from a 31.5 microM (2 mg/liter) Cu solution (128 +/- 11 and 130 +/- 11 pmol/min x cm, respectively, vs 101 +/- 4 pmol/min x cm, P less than 0.05, in the absence of carbohydrate). This was concomitant with a stimulation of net water absorption (1.05 +/- 0.08 and 0.84 +/- 0.08 microliter/min x cm, respectively, vs 0.63 +/- 0.02 microliter/min x cm with no carbohydrate, P less than 0.05). Glucose, fructose, lactose, or sucrose had no influence on Cu absorption, although they altered water exchanges, an effect attributable to a reduction of the outflow component of fluid recirculation. Low concentrations of lactose resulted in a greater accumulation of Cu in the intestinal mucosa (8.75 +/- 0.71 micrograms/g vs 5.77 +/- 0.68 micrograms/g for controls, P less than 0.05). Hence, solutes that moderately stimulate mucosa-to-serosa fluid influx in a progressive manner, such as glucose polymers, may contribute to functionally increase Cu absorption. Conversely, conditions which tend to reduce water inflow or increase water outflow across the small intestinal mucosa, as may occur with high lactose diets or in cases of chronic diarrhea, may have negative effects.

  7. Influence of circulating epinephrine on absorption of subcutaneously injected insulin

    International Nuclear Information System (INIS)

    Fernqvist, E.; Gunnarsson, R.; Linde, B.

    1988-01-01

    Effects of epinephrine (Epi) infusion on the absorption of subcutaneously injected 125I-labeled soluble human insulin (10 U) from the thigh or the abdomen were studied in 16 healthy subjects and from the thigh in 10 insulin-dependent diabetic (IDDM) patients. Epi was infused at 0.3 (high dose) or 0.1 (low dose; healthy subjects) nmol.kg-1.min-1 i.v., resulting in arterial plasma Epi levels of approximately 6 and 2 nM, respectively. Saline was infused on a control day. Insulin absorption was measured as disappearance of radioactivity from the injection site and as appearance of plasma immunoreactive insulin (IRI). Adipose tissue blood flow was measured with the 133Xe clearance technique. First-order disappearance rate constants of 125I from the thigh depot decreased approximately 40-50% during the high dose of Epi compared with control (P less than .001). The corresponding decrease from the abdominal depot was approximately 40% (P less than .001), whereas no significant change was found during the low Epi dose. IRI fell compared with control in all groups at the high Epi dose. The Epi-induced depression of insulin absorption occurred despite unaltered or even slightly increased subcutaneous blood flow. The results indicate that circulating Epi at levels seen during moderate physical stress depresses the absorption of soluble insulin from subcutaneous injection sites to an extent that might be important for glycemic control in IDDM patients. Furthermore, dissociation is found between changes in insulin absorption and subcutaneous blood flow during Epi infusion, suggesting that factors other than blood flow may also influence the absorption of subcutaneously injected insulin

  8. Use of atomic absorption spectrometry in assessment of biomonitor plants for lead, cadmium and copper pollution.

    Science.gov (United States)

    Gokce, Kaya; Mehmet, Yaman

    2012-01-01

    Eleven plant species were collected from the vicinity of lead-battery plant in the city of Gaziantep, Turkey. Lead, cadmium and copper concentrations in the soil and leaves of plants were determined by atomic absorption spectrometry. Lead, Cd and Cu concentrations in the soil samples taken from battery area were found to be in the ranges of 304-602, 0.4-0.44 and 31-37 mg x kg(-1), respectively. Significantly increased lead concentration up to 2 750 mg x kg(-1) was found in the leaves of Eleagnus angustifolia L. plant. The lead concentrations in the other plant leaves taken from 50 m around battery factory followed the order Ailanthus altissima > Morus sp. > Juglans regia L. > Ficus carica L. > Cydonia oblonga Miller > Prunus x domestica L. The plants, Populus nigra L. , Eleagnus angustifolia L. and Salix sp. were found useful for Cd, and the plant, Eleagnus angusti folia L. for Pb, to be considered as potential biomonitor. Especially, leaves of trees and plants taken from the distance of 50 m from battery plant have relatively higher Pb concentrations. Therefore, people who and animals which live in this area and benefit from these soil and plants have vital risks.

  9. Minimum mass of moderator required for criticality of homogeneous low-enriched uranium systems

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, W.C.; Turner, J.C.

    1992-12-01

    A parametric calculational analysis has been performed in order to estimate the minimum mass of moderator required for criticality of homogeneous low-enriched uranium systems. The analysis was performed using a version of the SCALE-4.0 code system and the 27-group ENDF/B-IV cross-section library. Water-moderated uranyl fluoride (UO{sub 2}F{sub 2} and H{sub 2}O) and hydrofluoric-acid-moderated uranium hexaflouride (UF{sub 6} and HF) systems were considered in the analysis over enrichments of 1.4 to 5 wt % {sup 235}U. Estimates of the minimum critical volume, minimum critical mass of uranium, and the minimum mass of moderator required for criticality are presented. There was significant disagreement between the values generated in this study when compared with a similar undocumented study performed in 1983 using ANISN and the Knight-modified Hansen-Roach cross sections. An investigation into the cause of the disagreement was made, and the results are presented.

  10. Minimum mass of moderator required for criticality of homogeneous low-enriched uranium systems

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, W.C.; Turner, J.C.

    1992-12-01

    A parametric calculational analysis has been performed in order to estimate the minimum mass of moderator required for criticality of homogeneous low-enriched uranium systems. The analysis was performed using a version of the SCALE-4.0 code system and the 27-group ENDF/B-IV cross-section library. Water-moderated uranyl fluoride (UO[sub 2]F[sub 2] and H[sub 2]O) and hydrofluoric-acid-moderated uranium hexaflouride (UF[sub 6] and HF) systems were considered in the analysis over enrichments of 1.4 to 5 wt % [sup 235]U. Estimates of the minimum critical volume, minimum critical mass of uranium, and the minimum mass of moderator required for criticality are presented. There was significant disagreement between the values generated in this study when compared with a similar undocumented study performed in 1983 using ANISN and the Knight-modified Hansen-Roach cross sections. An investigation into the cause of the disagreement was made, and the results are presented.

  11. Thermal neutron pulsed parameters in non-hydrogenous systems. Experiment for lead grains

    International Nuclear Information System (INIS)

    Drozdowicz, K.; Gabanska, B.; Kosik, M.; Krynicka, E.; Woznicka, U.; Zaleski, T.

    1997-01-01

    In Czubek's method of measurement of the thermal neutron macroscopic absorption cross section a two-region geometry is applied where the investigated sample is surrounded by an external moderator. Both regions in the measurements made up till now were hydrogenous, which means the same type of the thermal neutron transport properties. In the paper a theoretical consideration to use non-hydrogenous materials as the samples is presented. Pulsed neutron measurements have been performed on homogeneous material in a geometry of the classic experiment with the variable geometric buckling. Two decay constants have been measured for different cylindrical samples of small lead grains (a lead shot). (author)

  12. Low-Speed Wind-Tunnel Investigation of Blowing Boundary-Layer Control on Leading- and Trailing-Edge Flaps of a Large-Scale, Low-Aspect-Ratio, 45 Swept-wing Airplane Configuration

    Science.gov (United States)

    Maki, Ralph L.

    1959-01-01

    Blowing boundary-layer control was applied to the leading- and trailing-edge flaps of a 45 deg sweptback-wing complete model in a full-scale low-speed wind-tunnel study. The principal purpose of the study was to determine the effects of leading-edge flap deflection and boundary-layer control on maximum lift and longitudinal stability. Leading-edge flap deflection alone was sufficient to maintain static longitudinal stability without trailing-edge flaps. However, leading-edge flap blowing was required to maintain longitudinal stability by delaying leading-edge flow separation when trailing-edge flaps were deflected either with or without blowing. Partial-span leading-edge flaps deflected 60 deg with moderate blowing gave the major increase in maximum lift, although higher deflection and additional blowing gave some further increase. Inboard of 0.4 semispan leading-edge flap deflection could be reduced to 40 deg and/or blowing could be omitted with only small loss in maximum lift. Trailing-edge flap lift increments were increased by boundary-layer control for deflections greater than 45 deg. Maximum lift was not increased with deflected trailing-edge flaps with blowing.

  13. Oxidative stress, telomere shortening, and DNA methylation in relation to low-to-moderate occupational exposure to welding fumes.

    Science.gov (United States)

    Li, Huiqi; Hedmer, Maria; Wojdacz, Tomasz; Hossain, Mohammad Bakhtiar; Lindh, Christian H; Tinnerberg, Håkan; Albin, Maria; Broberg, Karin

    2015-10-01

    Evidence suggests that exposure to welding fumes is a risk factor for lung cancer. We examined relationships between low-to-moderate occupational exposure to particles from welding fumes and cancer-related biomarkers for oxidative stress, changes in telomere length, and alterations in DNA methylation. We enrolled 101 welders and 127 controls (all currently nonsmoking men) from southern Sweden. We performed personal sampling of respirable dust and measured 8-oxodG concentrations in urine using a simplified liquid chromatography tandem mass spectrometry method. Telomere length in peripheral blood was measured by quantitative polymerase chain reaction. Methylation status of 10 tumor suppressor genes was determined by methylation-sensitive high-resolution melting analysis. All analyses were adjusted for age, body mass index, previous smoking, passive smoking, current residence, and wood burning stove/boiler at home. Welders were exposed to respirable dust at 1.2 mg/m(3) (standard deviation, 3.3 mg/m(3); range, 0.1-19.3), whereas control exposures did not exceed 0.1 mg/m(3) (P < 0.001). Welders and controls did not differ in 8-oxodG levels (β = 1.2, P = 0.17) or relative telomere length (β = -0.053, P = 0.083) in adjusted models. Welders showed higher probability of adenomatous polyposis coli (APC) methylation in the unadjusted model (odds ratio = 14, P = 0.014), but this was not significant in the fully adjusted model (P = 0.052). Every working year as a welder was associated with 0.0066 units shorter telomeres (95% confidence interval -0.013 to -0.00053, P = 0.033). Although there were no clear associations between concentrations of respirable dust and the biomarkers, there were modest signs of associations between oxidative stress, telomere alterations, DNA methylation, and occupational exposure to low-to-moderate levels of particles. © 2015 Wiley Periodicals, Inc.

  14. Exploring the origin of high optical absorption in conjugated polymers

    KAUST Repository

    Vezie, Michelle S.; Few, Sheridan; Meager, Iain; Pieridou, Galatia; Dö rling, Bernhard; Ashraf, Raja Shahid; Goñ i, Alejandro R.; Bronstein, Hugo; McCulloch, Iain; Hayes, Sophia C.; Campoy-Quiles, Mariano; Nelson, Jenny

    2016-01-01

    The specific optical absorption of an organic semiconductor is critical to the performance of organic optoelectronic devices. For example, higher light-harvesting efficiency can lead to higher photocurrent in solar cells that are limited by sub-optimal electrical transport. Here, we compare over 40 conjugated polymers, and find that many different chemical structures share an apparent maximum in their extinction coefficients. However, a diketopyrrolopyrrole-thienothiophene copolymer shows remarkably high optical absorption at relatively low photon energies. By investigating its backbone structure and conformation with measurements and quantum chemical calculations, we find that the high optical absorption can be explained by the high persistence length of the polymer. Accordingly, we demonstrate high absorption in other polymers with high theoretical persistence length. Visible light harvesting may be enhanced in other conjugated polymers through judicious design of the structure.

  15. Exploring the origin of high optical absorption in conjugated polymers

    KAUST Repository

    Vezie, Michelle S.

    2016-05-16

    The specific optical absorption of an organic semiconductor is critical to the performance of organic optoelectronic devices. For example, higher light-harvesting efficiency can lead to higher photocurrent in solar cells that are limited by sub-optimal electrical transport. Here, we compare over 40 conjugated polymers, and find that many different chemical structures share an apparent maximum in their extinction coefficients. However, a diketopyrrolopyrrole-thienothiophene copolymer shows remarkably high optical absorption at relatively low photon energies. By investigating its backbone structure and conformation with measurements and quantum chemical calculations, we find that the high optical absorption can be explained by the high persistence length of the polymer. Accordingly, we demonstrate high absorption in other polymers with high theoretical persistence length. Visible light harvesting may be enhanced in other conjugated polymers through judicious design of the structure.

  16. Enhancement of optical absorption of Si (100) surfaces by low energy N+ ion beam irradiation

    Science.gov (United States)

    Bhowmik, Dipak; Karmakar, Prasanta

    2018-05-01

    The increase of optical absorption efficiency of Si (100) surface by 7 keV and 8 keV N+ ions bombardment has been reported here. A periodic ripple pattern on surface has been observed as well as silicon nitride is formed at the ion impact zones by these low energy N+ ion bombardment [P. Karmakar et al., J. Appl. Phys. 120, 025301 (2016)]. The light absorption efficiency increases due to the presence of silicon nitride compound as well as surface nanopatterns. The Atomic Force Microscopy (AFM) study shows the formation of periodic ripple pattern and increase of surface roughness with N+ ion energy. The enhancement of optical absorption by the ion bombarded Si, compared to the bare Si have been measured by UV - visible spectrophotometer.

  17. Criticality Data for Spherical 235U, 239Pu, and 237Np Systems Reflector-Moderated by Low Capturing-Moderator Materials

    International Nuclear Information System (INIS)

    Loaiza, David J.; Stratton, William

    2004-01-01

    The critical dimensions of spherical systems moderated and reflected by low-capturing materials such as D 2 O, BeO, Be, and C were investigated. A parametric study of the critical mass of enriched uranium, plutonium, and neptunium is examined and tabulated. The results obtained expand on the understanding of reflector-moderated critical systems, and they show regions of unstable criticality for 235 U and 239 Pu reflected cores at intermediate densities. This instability is illustrated by calculations of the positive reactivity coefficient of volume expansion. The coefficient is positive, not negative, in the intermediate density region for 235 U and 239 Pu systems. For 237 Np cores reflected by the same moderator, the effect is negligible. The critical dimensions were calculated with the DANTSYS codes using the Hansen-Roach cross-section libraries. This study is both a summary of mostly unpublished calculations and new calculations. Experimental data for these configurations are extremely limited. These are examined in the text when applicable

  18. The need for integral critical experiments with low-moderated MOX fuels

    International Nuclear Information System (INIS)

    2004-01-01

    The use of MOX fuel in commercial reactors is a means of burning plutonium originating from either surplus weapons or reprocessed irradiated uranium fuel. This requires the fabrication of MOX assemblies on an industrial scale. The OECD/NEA Expert Group on Experimental Needs for Criticality Safety has highlighted MOX fuel manufacturing, as an area in which there is a specific need for additional experimental data for validation purposes. Indeed, integral experiments with low-moderated MOX fuel are either scarce or not sufficiently accurate to provide an appropriate degree of validation of nuclear data and computer codes. New and accurate experimental data would enable a better optimisation of the fabrication process by decreasing the uncertainties in the determination of multiplication factors of configurations such as the homogenization of MOX powders. In this context, the OECD/NEA Nuclear Science Committee organised a workshop to address the following topics: expression and justification of the need for critical or near-critical experiments employing low-moderated MOX fuels; proposals for experimental programmes to address these needs; prospects for an international co-operative programme. The workshop was held at OECD headquarters in Paris on 14-15 April 2004. (author)

  19. Measurement of gamma attenuation coefficients in UO2 and zirconium for self-absorption corrections of burn-up determination

    International Nuclear Information System (INIS)

    Podest, M.; Klima, J.; Stecher, P.; Stecherova, E.

    1978-01-01

    UO 2 pellets from ALUOX fuel elements were used in measuring the absorption coefficient of gamma radiation in UO 2 . The results of measurements of the energy dependence of the linear absorption coefficient (within 622 to 796 keV) and of the dependence on pellet density showed that in the given density interval the absorption coefficient was almost constant. The density interval was chosen to be typical for pellet fuel used in water cooled and water moderated power reactors. The results are also shown of the dependence of the mass absorption coefficient of gamma radiation in Zr on radiation energy and compared with the mass absorption coefficient of Mo; these also showed the independence of the absorption coefficient on density. The linear and mass absorption coefficients of UO 2 are considerably high and correspond approximately to the absorption coefficient of lead. For the measured energy range the variation of absorption coefficient is about 40%, which causes errors in burnup determination. The efficiency was also determined of Ge(Li) detectors for the energy range 0.5 to 1.2 MeV. The determination of the above coefficients was used for improving the gamma fuel scanning technique in determining the activity and burnup of spent fuel elements. (J.P.)

  20. Intracorneal ring segments implantation followed by same-day topography-guided PRK and corneal collagen CXL in low to moderate keratoconus.

    Science.gov (United States)

    Al-Tuwairqi, Waleed; Sinjab, Mazen M

    2013-01-01

    To evaluate the safety and efficacy of intrastromal corneal ring segments (ICRS) implantation followed by same-day topography-guided photorefractive keratectomy (PRK) and ultraviolet-A/riboflavin collagen cross-linking (CXL) in patients with low to moderate keratoconus. Patients with low to moderate keratoconus and contact lens intolerance were included in the study. All patients first underwent femtosecond laser-enabled placement of ICRS (Keraring, Mediphacos) (first step). Same-day topography-guided PRK and CXL (second step) were subsequently performed in all patients after the refraction was stable (average 6 months [range: 3 to 11 months]). Thirteen eyes from 13 patients were included in the study. Based on values before the first step and 6 months after the second step, significant improvements were noted in uncorrected distance visual acuity (0.7±0.32 logMAR vs 0.08±0.08 logMAR), corrected distance visual acuity (CDVA) (0.16±0.19 logMAR vs 0.02±0.04 log-MAR), sphere (-3.65±3.08 diopters [D] vs 0.06±1.6 D), astigmatism (-3.31±1.5 D vs -0.98±0.75 D), average K (47.28±1.99 D vs 41.42±3.22 D), and coma (2.36±1.23 μm vs 1.47±0.68 μm) (PPRK/CXL may be a reasonable option for improving visual acuity in patients with low to moderate keratoconus. Copyright 2013, SLACK Incorporated.

  1. Neutron moderation at very low temperatures (1691); Moderation des neutrons aux tres basses temperatures (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Lacaze, A [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1961-04-15

    Starting from Harwell experiment carried out inside a low-power reactor, we intended to maintain a liquid hydrogen cell in a channel of the EL3 reactor (at Saclay) whose thermal neutrons flux is 10{sup 14} neutrons/cm{sup 2}/s. We tried to work out a device giving off an important beam of cold neutrons and able to operate in a way as automatic as possible during many consecutive day without a stop. Several circuits have already been achieved at very low temperatures but they brought out volumes and fluxes much lower than those we used this time. The difficulties we have met in carrying out such a device arose on the one hand from the very high energy release to which any kind of experiment is inevitably submitted when placed near the core of the reactor, on the other, hand from the very little room which is available in experimental channels of reactors. In such condition, it is necessary to use a moderator as effective as possible. This study is divided into three parts ; in the first part, we try to determine: a) conditions in which moderation takes place, hence the volume of the cell; b) materials likely to be used at low temperature and in pile; c) cooling system; hence we had to study fluid flow conditions at very low temperatures in very long ducts. The second part is devoted to the description of the device. The third part ventilates the results we have obtained. (author) [French] Partant de l'experience de Harwell faite dans une pile de faible puissance, nous nous sommes propose de maintenir une cellule d'hydrogene liquide dans un canal de la pile EL3 de Saclay dont le flux de neutrons thermiques est de 10{sup 14} neutrons par seconde et par cm{sup 2}. Nous avons cherche a realiser une installation donnant un faisceau de neutrons froids important, et pouvant fonctionner d'une maniere aussi automatique que possible, pendant des periodes de plusieurs jours sans arret. Plusieurs circuits aux tres basses temperatures ont deja ete realises, mais ils ne mettaient

  2. Tunable integration of absorption-membrane-adsorption for efficiently separating low boiling gas mixtures near normal temperature

    Science.gov (United States)

    Liu, Huang; Pan, Yong; Liu, Bei; Sun, Changyu; Guo, Ping; Gao, Xueteng; Yang, Lanying; Ma, Qinglan; Chen, Guangjin

    2016-01-01

    Separation of low boiling gas mixtures is widely concerned in process industries. Now their separations heavily rely upon energy-intensive cryogenic processes. Here, we report a pseudo-absorption process for separating low boiling gas mixtures near normal temperature. In this process, absorption-membrane-adsorption is integrated by suspending suitable porous ZIF material in suitable solvent and forming selectively permeable liquid membrane around ZIF particles. Green solvents like water and glycol were used to form ZIF-8 slurry and tune the permeability of liquid membrane surrounding ZIF-8 particles. We found glycol molecules form tighter membrane while water molecules form looser membrane because of the hydrophobicity of ZIF-8. When using mixing solvents composed of glycol and water, the permeability of liquid membrane becomes tunable. It is shown that ZIF-8/water slurry always manifests remarkable higher separation selectivity than solid ZIF-8 and it could be tuned to further enhance the capture of light hydrocarbons by adding suitable quantity of glycol to water. Because of its lower viscosity and higher sorption/desorption rate, tunable ZIF-8/water-glycol slurry could be readily used as liquid absorbent to separate different kinds of low boiling gas mixtures by applying a multistage separation process in one traditional absorption tower, especially for the capture of light hydrocarbons. PMID:26892255

  3. Influence of PbCl2 content in PbI2 solution of DMF on the absorption, crystal phase, morphology of lead halide thin films and photovoltaic performance in planar perovskite solar cells

    International Nuclear Information System (INIS)

    Wang, Mao; Shi, Chengwu; Zhang, Jincheng; Wu, Ni; Ying, Chao

    2015-01-01

    In this paper, the influence of PbCl 2 content in PbI 2 solution of DMF on the absorption, crystal phase and morphology of lead halide thin films was systematically investigated and the photovoltaic performance of the corresponding planar perovskite solar cells was evaluated. The result revealed that the various thickness lead halide thin film with the small sheet-like, porous morphology and low crystallinity can be produced by adding PbCl 2 powder into PbI 2 solution of DMF as a precursor solution. The planar perovskite solar cell based on the 300-nm-thick CH 3 NH 3 PbI 3−x Cl x thin film by the precursor solution with the mixture of 0.80 M PbI 2 and 0.20 M PbCl 2 exhibited the optimum photoelectric conversion efficiency of 10.12% along with an open-circuit voltage of 0.93 V, a short-circuit photocurrent density of 15.70 mA cm −2 and a fill factor of 0.69. - Graphical abstract: The figure showed the surface and cross-sectional SEM images of lead halide thin films using the precursor solutions: (a) 0.80 M PbI 2 , (b) 0.80 M PbI 2 +0.20 M PbCl 2 , (c) 0.80 M PbI 2 +0.40 M PbCl 2 , and (d) 0.80 M PbI 2 +0.60 M PbCl 2 . With the increase of the PbCl 2 content in precursor solution, the size of the lead halide nanosheet decreased and the corresponding thin films gradually turned to be porous with low crystallinity. - Highlights: • Influence of PbCl 2 content on absorption, crystal phase and morphology of thin film. • Influence of perovskite film thickness on photovoltaic performance of solar cell. • Lead halide thin film with small sheet-like, porous morphology and low crystallinity. • Planar solar cell with 300 nm-thick perovskite thin film achieved PCE of 10.12%.

  4. Influence of different moderator materials on characteristics of neutron fluxes generated under irradiation of lead target with proton beams

    International Nuclear Information System (INIS)

    Sosnin, A.N.; Polanski, A.; Petrochenkov, S.A.

    2002-01-01

    Neutron fields generated in extended heavy (Z ≥ 82) targets under irradiation with proton beams at energies in the range of 1 GeV are investigated. Influence of different moderators on the spectra and multiplicities of neutrons escaping the surface of the assembly consisting of a lead target (diam. 8 cm x 20 cm or diam. 8 cm x 50 cm) screened by variable thickness of polyethylene or graphite, respectively, was compared. It is shown that the effectiveness of graphite as a material used in such assemblies to moderate spallation neutrons down to thermal energies is significantly lower than that of paraffin

  5. Conditional Mediation of Absorptive Capacity and Environment in International Entrepreneurial Orientation of Family Businesses.

    Science.gov (United States)

    Hernández-Perlines, Felipe; Xu, Wenkai

    2018-01-01

    This study analyzes the effect of conditional mediation of environment-absorptive capacity in international entrepreneurial orientation of family businesses. Results involve data from 218 Spanish family businesses, analyzed with SmartPLS 3.2.7 software. This paper presents a relevant contribution both to the academic field and the performance of family firms, helping to understand the process of transforming international entrepreneurial orientation into a better international performance through absorptive capacity while family businesses invest their efforts in aligning international entrepreneurial orientation and absorptive capacity with international results, bearing in mind the positive moderator effect of environment. The most relevant contribution of this work is to integrate in the same model the mediating effect of the absorption capacity and the moderating effect of the environment: the effect of the international entrepreneurial orientation on the international performance of family businesses improves with the mediation of the absorptive capacity (the variability of international performance goes from 32.5 to 40.6%) and the moderation of the environment (to variability of international performance goes from 40.6 to 45.3%).

  6. Study on combustion characteristics of dimethyl ether under the moderate or intense low-oxygen dilution condition

    International Nuclear Information System (INIS)

    Kang, Yinhu; Lu, Tianfeng; Lu, Xiaofeng; Wang, Quanhai; Huang, Xiaomei; Peng, Shini; Yang, Dong; Ji, Xuanyu; Song, Yangfan

    2016-01-01

    Highlights: • Oxygen content in the flame base increased due to the prolonged ignition delay time. • Flow field in the furnace affected thermal/chemical structure of the flame partially. • Preheating and dilution facilitated moderate or intense low-oxygen dilution regime. • Dominant pollutant formation ways of dimethyl ether in hot dilution were clarified. • Preheating and dilution reduced nitrogen oxide emission of dimethyl ether. - Abstract: Experiments and numerical simulations were conducted in this paper to study the combustion behavior of dimethyl ether in the moderate or intense low-oxygen dilution regime, in terms of thermal/chemical structure and chemical kinetics associated with nitrogen oxide and carbon monoxide emissions. Several co-flow temperatures and oxygen concentrations were involved in the experiments to investigate their impacts on the flame behavior systematically. The results show that in the moderate or intense low-oxygen dilution regime, oxygen concentrations in the flame base slightly increased because of the prolonged ignition delay time of the reactant mixture due to oxidizer dilution, which changed the local combustion process and composition considerably. The oxidation rates of hydrocarbons were significantly depressed in the moderate or intense low-oxygen dilution regime, such that a fraction of unburned hydrocarbons at the furnace outlet were recirculated into the outer annulus of the furnace, which changed the local radial profiles of carbon monoxide, methane, and hydrogen partially. Moreover, with the increment in co-flow temperature or oxygen mole fraction, flame temperature, and hydroxyl radical, carbon monoxide, and hydrogen mole fractions across the reaction zone increased gradually. For the dimethyl ether-moderate or intense low-oxygen dilution flame, temperature homogeneity was improved at higher co-flow temperature or lower oxygen mole fraction. The carbon monoxide emission depended on the levels of temperature and

  7. Lead and cadmium content of spices

    Energy Technology Data Exchange (ETDEWEB)

    Bielig, H J; Dreyer, H; Askar, A

    1977-02-02

    The lead and cadmium content of various spices was determined by flameless atomic absorption (AAS). With the exception of one sample, the lead content was lower than 5 ppm, averaging a value of 2,2 ppm Pb. Thus, the maximum permissible level of 5 ppm Pb as recommended by different DIN standards, is not exceeded. The cadmium content was - except for one sample - lower than 0,5 ppm averaging a value of 0,23 ppm Cd. It can be assumed, that by spicing our dishes, the ingestion of lead and cadmium stays at a low level.

  8. Orthokeratologic Lens Applications in the Correction of Low to Moderate Myopia

    Directory of Open Access Journals (Sweden)

    Emine Kalkan Akçay

    2013-12-01

    Full Text Available Purpose: To evaluate the efficacy and safety of orthokeratology in patients with low and medium myopia. Material and Method: Twenty six eyes of 6 male and 7 female patients were evaluated prospectively. The mean spherical equivalent was -3.87±1.35 D (-7 - -2.25 in 26 eyes. Individual semi-rigid, gas-permeable night Gelflex lenses (Australia were performed based on keratometry values, ambient pupil, mesopic pupil, and autorefractometry values providing best-corrected visual acuity (BCVA. In all cases, uncorrected and best-corrected visual acuity, refraction, keratometry, corneal topography, slit lamp and intraocular pressure measurements were evaluated on first day, at first week, and at first, third and sixth months. Results: While the mean uncorrected visual acuity (UCVA before orthokeratology (Ortho-K was 1.08±0.24 (0.4-1.3 logMAR, first week after Ortho-K, it was 0.24±0.27 (0-1 logMAR. The BCVA was 0.01±0.07 (0-0.4 logMAR prior and first week after Ortho-K. First week after Ortho-K, it was 0.22 logMAR at right and 1 logMAR at left. While the average UCVA of our cases at first month was 0.11±0.19 (0-0.8 logMAR, the average BCVA at first month was 0.018±0.08 (0-0.4 logMAR. No ophthalmological complications were noted. Discussion: Ortho-K is a safe and effective method for correction of low and moderate myopia in patients who do not prefer surgery and do not wish to wear glasses or contact lenses during the day. (Turk J Ophthalmol 2013; 43: 317-20

  9. Photolysis mechanism of aqueous tyrosine upon excitation of the second absorption band

    International Nuclear Information System (INIS)

    Shimizu, O.

    1984-01-01

    The formation mechanism of tyrosinyl radical was studied for aqueous solutions of tyrosine under irradiation at 235 nm which falls into the second absorption band. The work is based upon the analysis of the rate of bityrosine production for steady-state excitation at low intensity. The results indicate that monophotonic O-H bond cleavage of tyrosine, presumably involving the upper excited triplet state, is the initial photoprocess leading to the tyrosinyl radical when tyrosine is excited into the second absorption band. (author)

  10. Comparative toxicity of tetra ethyl lead and lead oxide to earthworms, Eisenia fetida (Savigny)

    International Nuclear Information System (INIS)

    Venkateswara Rao, J.; Kavitha, P.; Padmanabha Rao, A.

    2003-01-01

    Leaded gasoline contains tetra ethyl lead (TEL) as an antiknocking agent, which produces major amounts of lead oxide in automobile exhaust along with traces of TEL. To minimize the lead contamination, methyl tertiary butyl ether (MTBE) is used as a substitute for producing unleaded gasoline. It has become increasingly apparent that young children are highly susceptible to the harmful effects of lead. Hence, a study was carried out to monitor lead toxicity in soil, using adult earthworms (Eisenia fetida, Savigny). Leaded gasoline (TEL) and lead oxide are 383- and 211-fold more toxic than unleaded gasoline (MTBE) in 7 days of exposure and 627- and 290-fold more toxic in 14 days, respectively. Results indicate that the presence of TEL in leaded gasoline and lead oxide has a significant effect on behavior, morphology, and histopathology of earthworms. Absorption of TEL into the tissues is comparatively less than that of lead oxide but toxic effects were severe. Rupture of the cuticle, extrusion of coelomic fluid and inflexible metameric segmentation were observed, causing desensitization of the posterior region leading to fragmentation in earthworms

  11. Anomalous optical surface absorption in nominally pure silicon samples at 1550 nm

    Science.gov (United States)

    Bell, Angus S.; Steinlechner, Jessica; Martin, Iain W.; Craig, Kieran; Cunningham, William; Rowan, Sheila; Hough, Jim; Schnabel, Roman; Khalaidovski, Alexander

    2017-10-01

    The announcement of the direct detection of gravitational waves (GW) by the LIGO and Virgo collaboration in February 2016 has removed any uncertainty around the possibility of GW astronomy. It has demonstrated that future detectors with sensitivities ten times greater than the Advanced LIGO detectors would see thousands of events per year. Many proposals for such future interferometric GW detectors assume the use of silicon test masses. Silicon has low mechanical loss at low temperatures, which leads to low displacement noise for a suspended interferometer mirror. In addition to the low mechanical loss, it is a requirement that the test masses have a low optical loss. Measurements at 1550 nm have indicated that material with a low enough bulk absorption is available; however there have been suggestions that this low absorption material has a surface absorption of  >100 ppm which could preclude its use in future cryogenic detectors. We show in this paper that this surface loss is not intrinsic but is likely to be a result of particular polishing techniques and can be removed or avoided by the correct polishing procedure. This is an important step towards high gravitational wave detection rates in silicon based instruments.

  12. Anomalous optical surface absorption in nominally pure silicon samples at 1550 nm

    International Nuclear Information System (INIS)

    Bell, Angus S; Steinlechner, Jessica; Martin, Iain W; Craig, Kieran; Cunningham, William; Rowan, Sheila; Hough, Jim; Schnabel, Roman; Khalaidovski, Alexander

    2017-01-01

    The announcement of the direct detection of gravitational waves (GW) by the LIGO and Virgo collaboration in February 2016 has removed any uncertainty around the possibility of GW astronomy. It has demonstrated that future detectors with sensitivities ten times greater than the Advanced LIGO detectors would see thousands of events per year. Many proposals for such future interferometric GW detectors assume the use of silicon test masses. Silicon has low mechanical loss at low temperatures, which leads to low displacement noise for a suspended interferometer mirror. In addition to the low mechanical loss, it is a requirement that the test masses have a low optical loss. Measurements at 1550 nm have indicated that material with a low enough bulk absorption is available; however there have been suggestions that this low absorption material has a surface absorption of  >100 ppm which could preclude its use in future cryogenic detectors. We show in this paper that this surface loss is not intrinsic but is likely to be a result of particular polishing techniques and can be removed or avoided by the correct polishing procedure. This is an important step towards high gravitational wave detection rates in silicon based instruments. (paper)

  13. Determination of lead associated with airborne particulate matter by flame atomic absorption and wave-length dispersive x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Talebi, S.M.

    1997-01-01

    The lead content of airborne particulate matter was determined by flame atomic absorption spectrometry (FAAS) following digestion with a mixture of nitric acid and hydrogen peroxide and also by wave-length dispersive x-ray fluorescence (WDXRF). The extraction procedure was checked by analyzing a standard reference material of airborne particulate matter (NIST, SRM -1648). It was concluded that lead can quantitatively (98%) be extracted from airborne particulate matter by the leaching process. A five-stage sequential extraction was performed to assess the potential mobility of lead associated with airborne particulate matter. Comparison of the airborne particulate lead measured by WDXRF to that measured by FAAS showed good agreement. The WDXRF method requires no time-consuming sample preparation or use of environmentally unfriendly solvents. The technique is suggested for direct determination of lead in airborne particulate matter in air pollution studies. (author)

  14. Developmental Delay in Moderately Preterm-Born Children with Low Socioeconomic Status : Risks Multiply

    NARCIS (Netherlands)

    Potijk, Marieke R; Kerstjens, Jorien M; Bos, Arend F; Reijneveld, Sijmen A; de Winter, Andrea F

    Objective To assess separate and joint effects of low socioeconomic status (SES) and moderate prematurity on preschool developmental delay. Study design Prospective cohort study with a community-based sample of preterm-and term-born children (Longitudinal Preterm Outcome Project). We assessed SES on

  15. Acute Exposure to Low-to-Moderate Carbon Dioxide Levels and Submariner Decision Making.

    Science.gov (United States)

    Rodeheffer, Christopher D; Chabal, Sarah; Clarke, John M; Fothergill, David M

    2018-06-01

    Submarines routinely operate with higher levels of ambient carbon dioxide (CO2) (i.e., 2000 - 5000 ppm) than what is typically considered normal (i.e., 400 - 600 ppm). Although significant cognitive impairments are rarely reported at these elevated CO2 levels, recent studies using the Strategic Management Simulation (SMS) test have found impairments in decision-making performance during acute CO2 exposure at levels as low as 1000 ppm. This is a potential concern for submarine operations, as personnel regularly make mission-critical decisions that affect the safety and efficiency of the vessel and its crew while exposed to similar levels of CO2. The objective of this study was to determine if submariner decision-making performance is impacted by acute exposure to levels of CO2 routinely present in the submarine atmosphere during sea patrols. Using a subject-blinded balanced design, 36 submarine-qualified sailors were randomly assigned to receive 1 of 3 CO2 exposure conditions (600, 2500, or 15,000 ppm). After a 45-min atmospheric acclimation period, participants completed an 80-min computer-administered SMS test as a measure of decision making. There were no significant differences for any of the nine SMS measures of decision making between the CO2 exposure conditions. In contrast to recent research demonstrating cognitive deficits on the SMS test in students and professional-grade office workers, we were unable to replicate this effect in a submariner population-even with acute CO2 exposures more than an order of magnitude greater than those used in previous studies that demonstrated such effects.Rodeheffer CD, Chabal S, Clarke JM, Fothergill DM. Acute exposure to low-to-moderate carbon dioxide levels and submariner decision making. Aerosp Med Hum Perform. 2018; 89(6):520-525.

  16. Impaired drug absorption due to high stomach pH: a review of strategies for mitigation of such effect to enable pharmaceutical product development.

    Science.gov (United States)

    Mitra, Amitava; Kesisoglou, Filippos

    2013-11-04

    Published reports have clearly shown that weakly basic drugs which have low solubility at high pH could have impaired absorption in patients with high gastric pH thus leading to reduced and variable bioavailability. Since such reduction in exposure can lead to significant loss of efficacy, it is imperative to (1) understand the behavior of the compound as a function of stomach pH to inform of any risk of bioavailability loss in clinical studies and (2) develop a robust formulation which can provide adequate exposure in achlorhydric patients. In this review paper, we provide an overview of the factors that can cause high gastric pH in human, discuss clinical and preclinical pharmacokinetic data for weak bases under conditions of normal and high gastric pH, and give examples of formulation strategies to minimize or mitigate the reduced absorption of weakly basic drugs under high gastric pH conditions. It should be noted that the ability to overcome pH sensitivity issues is highly compound dependent and there are no obvious and general solutions to overcome such effect. Further, we discuss, along with several examples, the use of biopharmaceutical tools such as in vitro dissolution, absorption modeling, and gastric pH modified animal models to assess absorption risk of weak bases in high gastric pH and also the use of these tools to enable development of formulations to mitigate such effects.

  17. Occupational exposure to lead--granulometric distribution of airborne lead in relation to risk assessment.

    Science.gov (United States)

    Carelli, G; Masci, O; Altieri, A; Castellino, N

    1999-07-01

    The amount of airborne lead absorbed by the body during occupational exposure depends not only on lead concentration in workplace air, but also on the granulometric distribution of the aerosol. The Occupational Safety and Health Administration (OSHA) set the lead Permissible Exposure Limit (PEL) at 50 micrograms/m3 on the basis of Bernard's model and a number of assumptions, including assumption "C", which predicts that the first 12.5 micrograms/m3 are made up of fine particles (aerodynamic diameter 1 micron. Occupational exposure to airborne lead at a concentration of 50 micrograms/m3 and a granulometric distribution calculated according to the above mentioned assumption, leads, in the model, to a mean blood level of 40 micrograms/dl. In the present study, we tested the validity of assumption "C" in the environmental air of a factory that manufactured crystal glassware containing 24% lead oxide. An 8-stage impactor was used to measure the particle size of airborne dust collected from personal and area samplings. Results indicate that, on the whole, assumption "C" cannot be considered valid in the work environment investigated in this study. As a result, lead absorption levels in exposed workers may be noticeably different from those predicted by the OSHA model. We therefore suggest that in order to make a correct evaluation of the risk of occupational exposure to lead, it is essential to integrate total airborne lead concentration with a measurement of the granulometric distribution of the aerosol.

  18. Prenatal exposure to lead in Spain: cord blood levels and associated factors.

    Science.gov (United States)

    Llop, Sabrina; Aguinagalde, Xabier; Vioque, Jesus; Ibarluzea, Jesús; Guxens, Mònica; Casas, Maribel; Murcia, Mario; Ruiz, María; Amurrio, Ascensión; Rebagliato, Marisa; Marina, Loreto Santa; Fernandez-Somoano, Ana; Tardon, Adonina; Ballester, Ferran

    2011-05-01

    Lead is a known neurotoxic. Fetuses and infants are very vulnerable to lead exposure, since their blood-brain barrier is not completely formed. Hence, there is an importance for monitoring of blood lead levels prenatally and during early infancy. The aim of this study is to evaluate the prenatal exposure to lead and its association with maternal factors in four population based mother-child cohorts in Spain. The present research was carried out within the framework of the INMA project INfancia y Medio Ambiente (Environment and Childhood). A total of 1462 pregnant women were recruited between 2004 and 2008. Lead was analyzed in a sample of cord blood by thermal decomposition, amalgation, and Atomic Absorption Spectrometry. Maternal sociodemographic, lifestyle and dietary factors were obtained by questionnaires during pregnancy. A multivariate logistic regression model was constructed. The dependent variable was a dichotomous lead level variable (detected vs no detected, i.e. ≥ vs < 2μg/dL). A low percentage of cord blood samples with lead levels ≥ 2μg/dL were found (5.9%). Geometric mean and maximum were 1.06μg/dL and 19μg/dL, respectively. Smoking at the beginning of pregnancy, age, social class, weight gain during pregnancy, gravidity, and place of residence were the maternal factors associated with detectable cord blood lead levels. Mother's diet does not appear to be a determining factor of lead exposure. Nevertheless, daily intake of iron and zinc may act as a protective factor against having cord blood lead levels ≥ 2μg/dL. In the different regions of Spain taking part in this study, lead levels to which newborns are exposed are low. Mobilization of lead from bones may be the main contributor to the cord blood levels. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Gauging the Impact of Various Definitions of Low- and Moderate-Income Communities on Possible Electricity Savings From Weatherization

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, Ian M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-06-20

    With rising interest in lowering energy costs for low- and moderate-income households, the U.S. Department of Energy (DOE) asked Lawrence Berkeley National Laboratory (LBNL) to assess the implications of pursuing energy efficiency neighborhood-by-neighborhood where those households are most prevalent. DOE provided certain scenarios for qualifying geographic areas as “low- and moderate-income communities,” and LBNL used data on demographics, housing types and recent savings from low-income retrofits or weatherization to provide rough electricity savings estimates under those scenarios.

  20. Analysis of the absorption coefficient by annealing in carbon implanted Nd: YVO4

    International Nuclear Information System (INIS)

    Sanchez-Morales, M E; Vazquez, G V; Lifante, G; Cantelar, E; Rickards, J; Trejo-Luna, R

    2011-01-01

    Low loss in optical waveguides is very important in order to achieve high laser efficiency. Waveguide fabrication by ion implantation generates color centers, leading to absorption losses which can be reduced by annealing; however, this process may eliminate the waveguide and hence it is necessary to consider both the optimum annealing time and temperature. This work reports the behavior of the absorption coefficient by successive annealing steps in Nd:YVO 4 implanted with a dose of 5xl0 14 ions/cm 2 .

  1. Consumption of low-moderate level arsenic contaminated water does not increase spontaneous pregnancy loss: a case control study.

    Science.gov (United States)

    Bloom, Michael S; Neamtiu, Iulia A; Surdu, Simona; Pop, Cristian; Lupsa, Ioana Rodica; Anastasiu, Doru; Fitzgerald, Edward F; Gurzau, Eugen S

    2014-10-13

    Previous work suggests an increased risk for spontaneous pregnancy loss linked to high levels of inorganic arsenic (iAs) in drinking water sources (>10 μg/L). However, there has been little focus to date on the impact of low-moderate levels of iAs in drinking water (control study in Timis County, Romania. We recruited women with incident spontaneous pregnancy loss of 5-20 weeks completed gestation as cases (n = 150), and women with ongoing pregnancies matched by gestational age (±1 week) as controls (n = 150). Participants completed a physician-administered questionnaire and we collected water samples from residential drinking sources. We reconstructed residential drinking water exposure histories using questionnaire data weighted by iAs determined using hydride generation-atomic absorption spectrometry (HG-AAS). Logistic regression models were used to generate odds ratios (OR) and 95% confidence intervals (CI) for associations between iAs exposure and loss, conditioned on gestational age and adjusted for maternal age, cigarette smoking, education and prenatal vitamin use. We explored potential interactions in a second set of models. Drinking water arsenic concentrations ranged from 0.0 to 175.1 μg/L, with median 0.4 μg/L and 90th%tile 9.4 μg/L. There were no statistically significant associations between loss and average or peak drinking water iAs concentrations (OR 0.98, 95% CI 0.96-1.01), or for daily iAs intake (OR 1.00, 95% CI 0.98-1.02). We detected modest evidence for an interaction between average iAs concentration and cigarette smoking during pregnancy (P = 0.057) and for daily iAs exposure and prenatal vitamin use (P = 0.085). These results suggest no increased risk for spontaneous pregnancy loss in association with low to moderate level drinking water iAs exposure. Though imprecise, our data also raise the possibility for increased risk among cigarette smokers. Given the low exposures overall, these data should reassure pregnant

  2. LED-Absorption-QEPAS Sensor for Biogas Plants

    Science.gov (United States)

    Köhring, Michael; Böttger, Stefan; Willer, Ulrike; Schade, Wolfgang

    2015-01-01

    A new sensor for methane and carbon dioxide concentration measurements in biogas plants is presented. LEDs in the mid infrared spectral region are implemented as low cost light source. The combination of quartz-enhanced photoacoustic spectroscopy with an absorption path leads to a sensor setup suitable for the harsh application environment. The sensor system contains an electronics unit and the two gas sensors; it was designed to work as standalone device and was tested in a biogas plant for several weeks. Gas concentration dependent measurements show a precision better than 1% in a range between 40% and 60% target gas concentration for both sensors. Concentration dependent measurements with different background gases show a considerable decrease in cross sensitivity against the major components of biogas in direct comparison to common absorption based sensors. PMID:26007746

  3. LED-Absorption-QEPAS Sensor for Biogas Plants

    Directory of Open Access Journals (Sweden)

    Michael Köhring

    2015-05-01

    Full Text Available A new sensor for methane and carbon dioxide concentration measurements in biogas plants is presented. LEDs in the mid infrared spectral region are implemented as low cost light source. The combination of quartz-enhanced photoacoustic spectroscopy with an absorption path leads to a sensor setup suitable for the harsh application environment. The sensor system contains an electronics unit and the two gas sensors; it was designed to work as standalone device and was tested in a biogas plant for several weeks. Gas concentration dependent measurements show a precision better than 1% in a range between 40% and 60% target gas concentration for both sensors. Concentration dependent measurements with different background gases show a considerable decrease in cross sensitivity against the major components of biogas in direct comparison to common absorption based sensors.

  4. Effects of low-level prenatal lead exposure on child IQ at 4 and 8 years in a UK birth cohort study.

    Science.gov (United States)

    Taylor, Caroline M; Kordas, Katarzyna; Golding, Jean; Emond, Alan M

    2017-09-01

    The association between childhood exposure to lead (Pb) and deficits in cognitive function is well established. The association with prenatal exposure, however, is not well understood, even though the potential adverse effects are equally important. To evaluate the association between low prenatal exposure to lead and IQ in children, to determine whether there were sex differences in the associations, and to evaluate the moderation effect of prenatal Pb exposure on child IQ. Whole blood samples from pregnant women enrolled in ALSPAC (n=4285) and from offspring at age 30 months (n=235) were analysed for Pb. Associations between prenatal blood lead concentrations (B-Pb) and child IQ at age 4 and 8 years (WPPSI and WISC-III, respectively) were examined in adjusted regression models. There was no association of prenatal lead exposure with child IQ at 4 or 8 years old in adjusted regression models, and no moderation of the association between child B-Pb and IQ. However, there was a positive association for IQ at age 8 years in girls with a predicted increase in IQ (points) per 1μg/dl of: verbal 0.71, performance 0.57, total 0.73. In boys, the coefficients tended to be negative (-0.15, -0.42 and -0.29 points, respectively). Prenatal lead exposure was not associated with adverse effects on child IQ at age 4 or 8 years in this study. There was, however, some evidence to suggest that boys are more susceptible than girls to prenatal exposure to lead. Further investigation in other cohorts is required. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  5. Multiwalled carbon nanotubes as a sorbent material for the solid phase extraction of lead from urine and subsequent determination by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Peña Crecente, Rosa M.; Lovera, Carlha Gutiérrez; García, Julia Barciela; Méndez, Jennifer Álvarez; Martín, Sagrario García; Latorre, Carlos Herrero, E-mail: carlos.herrero@usc.es

    2014-11-01

    The determination of lead in urine is a way of monitoring the chemical exposure to this metal. In the present paper, a new method for the Pb determination by electrothermal atomic absorption spectrometry (ETAAS) in urine at low levels has been developed. Lead was separated from the undesirable urine matrix by means of a solid phase extraction (SPE) procedure. Oxidized multiwalled carbon nanotubes have been used as a sorbent material. Lead from urine was retained at pH 4.0 and was quantitatively eluted using a 0.7 M nitric acid solution and was subsequently measured by ETAAS. The effects of parameters that influence the adsorption–elution process (such as pH, eluent volume and concentration, sampling and elution flow rates) and the atomic spectrometry conditions have been studied by means of different factorial design strategies. Under the optimized conditions, the detection and quantification limits obtained were 0.08 and 0.26 μg Pb L{sup −1}, respectively. The results demonstrate the absence of a urine matrix effect and this is the consequence of the SPE process carried out. Therefore, the developed method is useful for the analysis of Pb at low levels in real samples without the influence of other urine components. The proposed method was applied to the determination of lead in urine samples of unexposed healthy people and satisfactory results were obtained (in the range 3.64–22.9 μg Pb L{sup −1}). - Highlights: • Lead determination in urine using a solid phase extraction procedure followed by ETAAS • Carbon nanotubes as SPE adsorbent for Pb in urine • Matrix elimination for the Pb determination in urine by using SPE based on carbon nanotubes • The detection limit was 0.08 μg Pb L{sup −1}.

  6. Influence of Different Moderator Materials on Characteristics of Neutron Fluxes Generated under Irradiation of Lead Target with Proton Beams

    CERN Document Server

    Sosnin, A N; Polanski, A; Petrochenkov, S A; Golovatyuk, V M; Krivopustov, M I; Bamblevski, V P; Westmeier, W; Odoj, R; Brandt, R; Robotham, H; Hashemi-Nezhad, S R; Zamani-Valassiadou, M

    2002-01-01

    Neutron fields generated in extended heavy (Z\\geq 82) targets under irradiation with proton beams at energies in the range of 1 GeV are investigated. Influence of different moderators on the spectra and multiplicities of neutrons escaping the surface of the assembly consisting of a lead target (\\varnothing 8 cm\\times 20 cm or \\varnothing 8cm\\times 50 cm) screened by variable thickness of polyethylene or graphite, respectively, was compared in the present work. It is shown that the effectiveness of graphite as a material used in such assemblies to moderate spallation neutrons down to thermal energies is significantly lower than that of paraffin.

  7. Low-Absorption Liquid Crystals for Infrared Beam Steering

    Science.gov (United States)

    2015-09-30

    controlled the curing temperature at 0oC to obtain small domain size and fast response time is expected. Here, a UV light-emitting diode ( LED ) lamp ...absorption; def.=deformation; w =weak absorption; v.=variable intensity) [B. D. Mistry, A Handbook of Spectroscopic Data: Chemistry- UV , IR, PMR, CNMR and...contributed by the core structure and terminal groups. Due to UV instability of double bonds and carbon-carbon triple bonds, conjugated phenyl rings have

  8. Calcium absorption response to cholecalciferol supplementation in hemodialysis.

    Science.gov (United States)

    Armas, Laura A G; Zena, Mohsen; Lund, Richard; Heaney, Robert P

    2013-06-01

    Recent understanding of extrarenal production of calcitriol has led to the use of more vitamin D supplementation in CKD populations. This paper reports the effect of cholecalciferol supplementation on calcium absorption. Paired calcium absorption tests were done before and after 12-13 weeks of 20,000 IU weekly cholecalciferol supplementation in 30 participants with stage 5 CKD on hemodialysis. The study was conducted from April to December of 2011. Calcium absorption was tested with a standardized meal containing 300 mg calcium carbonate intrinsically labeled with (45)Ca; 25-hydroxyvitamin D and 1,25-dihydroxyvitamin D were measured. 25-Hydroxyvitamin D rose from 14.2 ng/ml (11.5-18.5) at baseline to 49.3 ng/ml (42.3-58.1) at the end of the study (P<0.001). 1,25-Dihydroxyvitamin D rose from 15.1 (10.5-18.8) pg/ml at baseline to 20.5 (17.0-24.7) pg/ml at the end of the study (P<0.001). The median baseline calcium absorption was 12% (7%-17%) and 12% (7%-16%) at the end of study. Patients with stage 5 CKD on hemodialysis had very low calcium absorption values at baseline, and cholecalciferol supplementation that raised 25(OH)D levels to 50 ng/ml had no effect on calcium absorption.

  9. Low Annexin A1 expression predicts benefit from induction chemotherapy in oral cancer patients with moderate or poor pathologic differentiation grade

    International Nuclear Information System (INIS)

    Zhu, Dong-wang; Zhang, Chen-ping; Zhang, Zhi-yuan; Zhong, Lai-ping; Liu, Ying; Yang, Xiao; Yang, Cheng-zhe; Ma, Jie; Yang, Xi; Qiao, Jin-ke; Wang, Li-zhen; Li, Jiang

    2013-01-01

    The benefit of induction chemotherapy in locally advanced oral squamous cell carcinoma (OSCC) remains to be clearly defined. Induction chemotherapy is likely to be effective for biologically distinct subgroups of patients and biomarker development might lead to identification of the patients whose tumors are to respond to a particular treatment. Annexin A1 may serve as a biomarker for responsiveness to induction chemotherapy. The aim of this study was to investigate Annexin A1 expression in pre-treatment biopsies from a cohort of OSCC patients treated with surgery and post-operative radiotherapy or docetaxel, cisplatin and 5-fluorouracil (TPF) induction chemotherapy followed by surgery and post-operative radiotherapy. Furthermore we sought to assess the utility of Annexin A1 as a prognostic or predictive biomarker. Immunohistochemical staining for Annexin A1 was performed in pre-treatment biopsies from 232 of 256 clinical stage III/IVA OSCC patients. Annexin A1 index was estimated as the proportion of tumor cells (low and high, <50% and ≥50% of stained cells, respectively) to Annexin A1 cellular membrane and cytoplasm staining. There was a significant correlation between Annexin A1 expression and pathologic differentiation grade (P=0.015) in OSCC patients. The proportion of patients with low Annexin A1 expression was significantly higher amongst those with moderate/poorly differentiated tumor (78/167) compared to those with well differentiated tumor (18/65). Multivariate Cox model analysis showed clinical stage (P=0.001) and Annexin A1 expression (P=0.038) as independent prognostic risk factors. Furthermore, a low Annexin A1 expression level was predictive of longer disease-free survival (P=0.036, HR=0.620) and locoregional recurrence-free survival (P=0.031, HR=0.607) compared to high Annexin A1 expression. Patients with moderate/poorly differentiated tumor and low Annexin A1 expression benefited from TPF induction chemotherapy as measured by distant metastasis

  10. Lead poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Beijers, J A

    1952-01-01

    Three cases of acute lead poisoning of cattle herds via ingestion are reported, and reference is made to several other incidents of lead in both humans and animals. The quantity of lead which was found in the livers of the dead cows varied from 6.5 to 19 mg/kg, while 1160 mg/kg of lead in the liver was found for a young cow which was poisoned experimentally with 5 gms of lead acetate per day; hence, there appears to be great variability in the amounts deposited that can lead to intoxication and death. No evidence was found for a lead seam around the teeth, prophyrinuria, or basophil granules in the erythrocytes during acute or chronic lead poisoning of cattle or horses examined. Reference is made to attempts of finding the boundary line between increased lead absorption and lead intoxication in humans, and an examination of 60 laborers in an offset-printing office containing a great deal of inhalable lead (0.16 to 1.9 mg/cu m air) is reviewed. Physical deviation, basophylic granulation of erythrocytes, increased lead content of the urine, and porphyrinuria only indicate an increased absorption of lead; the use of the term intoxication is justified if, in addition, there are complaints of lack of appetite, constipation, fatigue, abdominal pain, and emaciation.

  11. Geospatial Absorption and Regional Effects

    Directory of Open Access Journals (Sweden)

    IOAN MAC

    2009-01-01

    Full Text Available The geospatial absorptions are characterized by a specific complexity both in content and in their phenomenological and spatial manifestation fields. Such processes are differentiated according to their specificity to pre-absorption, absorption or post-absorption. The mechanisms that contribute to absorption are extremely numerous: aggregation, extension, diffusion, substitution, resistivity (resilience, stratification, borrowings, etc. Between these mechanisms frequent relations are established determining an amplification of the process and of its regional effects. The installation of the geographic osmosis phenomenon in a given territory (a place for example leads to a homogenization of the geospatial state and to the installation of the regional homogeneity.

  12. Low-level human equivalent gestational lead exposure produces sex-specific motor and coordination abnormalities and late-onset obesity in year-old mice.

    Science.gov (United States)

    Leasure, J Leigh; Giddabasappa, Anand; Chaney, Shawntay; Johnson, Jerry E; Pothakos, Konstantinos; Lau, Yuen Sum; Fox, Donald A

    2008-03-01

    Low-level developmental lead exposure is linked to cognitive and neurological disorders in children. However, the long-term effects of gestational lead exposure (GLE) have received little attention. Our goals were to establish a murine model of human equivalent GLE and to determine dose-response effects on body weight, motor functions, and dopamine neurochemistry in year-old offspring. We exposed female C57BL/6 mice to water containing 0, 27 (low), 55 (moderate), or 109 ppm (high) of lead from 2 weeks prior to mating, throughout gestation, and until postnatal day 10 (PN10). Maternal and litter measures, blood lead concentrations ([BPb]), and body weights were obtained throughout the experiment. Locomotor behavior in the absence and presence of amphetamine, running wheel activity, rotarod test, and dopamine utilization were examined in year-old mice. Peak [BPb] were obesity. Similarly, we observed male-specific decreased spontaneous motor activity, increased amphetamine-induced motor activity, and decreased rotarod performance in year-old GLE mice. Levels of dopamine and its major metabolite were altered in year-old male mice, although only forebrain utilization increased. GLE-induced alterations were consistently larger in low-dose GLE mice. Our novel results show that GLE produced permanent male-specific deficits. The nonmonotonic dose-dependent responses showed that low-level GLE produced the most adverse effects. These data reinforce the idea that lifetime measures of dose-response toxicant exposure should be a component of the neurotoxic risk assessment process.

  13. Determination of lead and cadmium in hen eggs by graphite france electrothermal atomic absorption spectrometry and estimation of the daily intake

    International Nuclear Information System (INIS)

    Siddiqui, I.; Nizami, S.S.

    2012-01-01

    A total of 54 hen eggs were procured from nine poultry farms of Sindh, Pakistan in different batches to determine lead and cadmium toxicity. The quantitative analysis of lead (Pb) and cadmium (Cd) in egg samples were performed on electrothermal atomic absorption spectrometer (ETAAS), with Zeeman effects background correction. Lead concentrations in hen egg samples ranged from 0.027 to 1.056 micro g/g with a mean value of 0.283 micro g/g +- 0.86, whereas cadmium concentrations ranged from 0.001 to 0.012 micro g/g with a mean value of 0.003 micro g/g +-0.002. Lead concentrations exceeded the normal levels of 0.020 but cadmium was found lower than the normal levels of 0.005 micro g/g. (author)

  14. Charge carrier recombination channels in the low-temperature phase of organic-inorganic lead halide perovskite thin films

    Science.gov (United States)

    Wehrenfennig, Christian; Liu, Mingzhen; Snaith, Henry J.; Johnston, Michael B.; Herz, Laura M.

    2014-08-01

    The optoelectronic properties of the mixed hybrid lead halide perovskite CH3NH3PbI3-xClx have been subject to numerous recent studies related to its extraordinary capabilities as an absorber material in thin film solar cells. While the greatest part of the current research concentrates on the behavior of the perovskite at room temperature, the observed influence of phonon-coupling and excitonic effects on charge carrier dynamics suggests that low-temperature phenomena can give valuable additional insights into the underlying physics. Here, we present a temperature-dependent study of optical absorption and photoluminescence (PL) emission of vapor-deposited CH3NH3PbI3-xClx exploring the nature of recombination channels in the room- and the low-temperature phase of the material. On cooling, we identify an up-shift of the absorption onset by about 0.1 eV at about 100 K, which is likely to correspond to the known tetragonal-to-orthorhombic transition of the pure halide CH3NH3PbI3. With further decreasing temperature, a second PL emission peak emerges in addition to the peak from the room-temperature phase. The transition on heating is found to occur at about 140 K, i.e., revealing significant hysteresis in the system. While PL decay lifetimes are found to be independent of temperature above the transition, significantly accelerated recombination is observed in the low-temperature phase. Our data suggest that small inclusions of domains adopting the room-temperature phase are responsible for this behavior rather than a spontaneous increase in the intrinsic rate constants. These observations show that even sparse lower-energy sites can have a strong impact on material performance, acting as charge recombination centres that may detrimentally affect photovoltaic performance but that may also prove useful for optoelectronic applications such as lasing by enhancing population inversion.

  15. Intervening O vi Quasar Absorption Systems at Low Redshift: A Significant Baryon Reservoir.

    Science.gov (United States)

    Tripp; Savage; Jenkins

    2000-05-01

    Far-UV echelle spectroscopy of the radio-quiet QSO H1821+643 (zem=0.297), obtained with the Space Telescope Imaging Spectrograph (STIS) at approximately 7 km s-1 resolution, reveals four definite O vi absorption-line systems and one probable O vi absorber at 0.15quasar in redshift; these are likely intervening systems unrelated to the background QSO. In the case of the strong O vi system at zabs=0.22497, multiple components are detected in Si iii and O vi as well as H i Lyman series lines, and the differing component velocity centroids and b-values firmly establish that this is a multiphase absorption system. A weak O vi absorber is detected at zabs=0.22637, i.e., offset by approximately 340 km s-1 from the zabs=0.22497 system. Lyalpha absorption is detected at zabs=0.22613, but no Lyalpha absorption is significantly detected at 0.22637. Other weak O vi absorbers at zabs=0.24531 and 0.26659 and the probable O vi system at 0.21326 have widely diverse O vi/H i column density ratios with N(O vi)/N(H i) ranging from to 5.2+/-1.2. The number density of O vi absorbers with rest equivalent width greater than 30 mÅ in the H1821+643 spectrum is remarkably high, dN&solm0;dz approximately 48, which implies with a high (90%) confidence that it is greater than 17 in the low-redshift intergalactic medium. We conservatively estimate that the cosmological mass density of the O vi systems is Omegab(Ovi&parr0; greater, similar0.0008 h-175. With an assumed metallicity of 1/10 solar and a conservative assumption that the fraction of oxygen in the O vi ionization stage is 0.2, we obtain Omegab(Ovi&parr0; greater, similar0.004 h-175. This is comparable to the combined cosmological mass density of stars and cool gas in galaxies and X-ray-emitting gas in galaxy clusters at low redshift.

  16. Blood lead level and its relationship to essential elements in preschool children from Nanning, China.

    Science.gov (United States)

    Chen, Jingwen; Li, Muyan; Lv, Qun; Chen, Guoli; Li, Yong; Li, Shaojun; Mo, Yuhuan; Ou, Shiyan; Yuan, Zongxiang; Huang, Mingli; Jiang, Yueming

    2015-04-01

    Our study aimed to assess the distribution of blood lead level and its relationship to essential elements in preschool children in an urban area of China. A total of 6741 children aged 0- to 6-year-old were recruited. Levels of lead, zinc, copper, iron, calcium, and magnesium in whole blood samples were determined using atomic absorption spectrometry. The mean blood lead level (BLL) and the prevalence of BLL≥10μg/dl (5.26±4.08μg/dl and 6.84%, respectively) increased with age gradually, and there was a gender-difference for blood lead, copper, zinc and iron levels. Compared with the group of children who had BLLslead with zinc, iron and magnesium, and a negative correlation of lead with calcium were found in the group of children with BLLintoxication prevalence in preschool children. Metabolic disorder of essential elements was found even with a low level of lead exposure. Copyright © 2014 Elsevier GmbH. All rights reserved.

  17. The moderating role of brands for low income luxury consumers

    Directory of Open Access Journals (Sweden)

    Flavio Santino Bizarrias

    2017-09-01

    Full Text Available The value of luxury is a multidimensional construct that assesses how consumers consider the various dimensions of luxury in their consumption relations. The consumption of luxury is not a trivial activity for most people, but brings a certain fascination and is part of the imaginary of the lower classes in emerging markets. The social identity of these consumers is changing because they aspire a new social position. But luxury consumption hurts the standards of this consumer profile. At the same time the self esteem is observed as an important element of people self-confirmation. For consumers, specifically, self-esteem is an important antecedent of consumption decisions. A sample of low income students was analyzed in this study to describe their relationship with luxury, and its influence on self-esteem when moderated by brand expressiveness. Through structural equation modeling this study found that the expression of the brand moderates the relationship of the value of luxury with self-esteem, allowing consumers of lower classes to observe a significant role of luxury in their lives.

  18. Combination of dispersive liquid-liquid microextraction with flame atomic absorption spectrometry using microsample introduction for determination of lead in water samples.

    Science.gov (United States)

    Naseri, Mohammad Taghi; Hemmatkhah, Payam; Hosseini, Mohammad Reza Milani; Assadi, Yaghoub

    2008-03-03

    The dispersive liquid-liquid microextraction (DLLME) was combined with the flame atomic absorption spectrometry (FAAS) for determination of lead in the water samples. Diethyldithiophosphoric acid (DDTP), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. A new FAAS sample introduction system was employed for the microvolume nebulization of the non-flammable chlorinated organic extracts. Injection of 20 microL volumes of the organic extract into an air-acetylene flame provided very sensitive spike-like and reproducible signals. Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters include extraction and disperser solvent type as well as their volume, extraction time, salt effect, pH and amount of the chelating agent. Under the optimized conditions, the enrichment factor of 450 was obtained from a sample volume of 25.0 mL. The enhancement factor, calculated as the ratio of the slopes of the calibration graphs with and without preconcentration, which was about 1000. The calibration graph was linear in the range of 1-70 microgL(-1) with a detection limit of 0.5 microgL(-1). The relative standard deviation (R.S.D.) for seven replicate measurements of 5.0 and 50 microgL(-1) of lead were 3.8 and 2.0%, respectively. The relative recoveries of lead in tap, well, river and seawater samples at the spiking level of 20 microgL(-1) ranged from 93.8 to 106.2%. The characteristics of the proposed method were compared with those of the liquid-liquid extraction (LLE), cloud point extraction (CPE), on-line and off-line solid-phase extraction (SPE) as well as co-precipitation, based on bibliographic data. Operation simplicity, rapidity, low cost, high enrichment factor, good repeatability, and low consumption of the extraction solvent at a microliter level are the main advantages of the proposed method.

  19. Re-exposure to low osmolar iodinated contrast media in patients with prior moderate-to-severe hypersensitivity reactions: A multicentre retrospective cohort study.

    Science.gov (United States)

    Park, Hye Jung; Park, Jung-Won; Yang, Min-Suk; Kim, Mi-Yeong; Kim, Sae-Hoon; Jang, Gwang Cheon; Nam, Young-Hee; Kim, Gun-Woo; Kim, Sujeong; Park, Hye-Kyung; Jung, Jae-Woo; Park, Jong-Sook; Kang, Hye-Ryun

    2017-07-01

    To evaluate the outcomes of re-exposure to low-osmolar iodinated contrast medium (LOCM) in patients with a history of moderate-to-severe hypersensitivity reaction (HSR). We retrospectively evaluated a cohort comprising all subjects satisfying the following conditions at 11 centres: (1) experienced a moderate-to-severe HSR to LOCM by December 2014, and (2) underwent contrast-enhanced computed tomography after the initial HSR between January 2014 and December 2014. A total of 150 patients with 328 instances of re-exposure were included; the recurrence rate of HSR was 19.5%. Patients with severe initial HSR exhibited a higher recurrence rate of severe HSR compared to patients with moderate initial HSR, despite more intensive premedication. In the multivariate analysis, the independent risk factors for recurrence of HSR were diabetes, chronic urticaria, drug allergy other than to iodinated contrast media (ICM) and severe initial HSR. The risk of recurrent HSR was 67.1% lower in cases where the implicated ICM was changed to another one (odds ratio: 0.329; P = 0.001). However, steroid premedication did not show protective effects against recurrent HSR. In high-risk patients who have previously experienced a moderate-to-severe initial HSR to LOCM, we should consider changing the implicated ICM to reduce recurrence risk. • In patients with moderate-to-severe HSR, steroid premedication only shows limited effectiveness. • Changing the implicated ICM can reduce the recurrence of HSR to ICM. • Diabetes, chronic urticaria and drug allergies increase the risk of ICM HSR.

  20. On absorption of low frequency electromagnetic fields

    International Nuclear Information System (INIS)

    Brunner, S.; Vaclavik, J.

    1993-03-01

    The drift kinetic equation (DKE) is used to establish a formula for power absorption of small amplitude, low frequency electromagnetic (EM) fields in a hot toroidal axisymmetric plasma. The stationary plasma is first considered. Electrons and ions are described by local Maxwellian distributions, alpha particles by a local slowing-down distribution. The fluctuating part of the distribution function for each species is then evaluated from the linearized DKE in terms of the EM fields using a perturbation method. The parameter b p =B p /B o , where B p is the poloidal component of the magnetostatic field B o , and the parameter v d /λω, where v d is the magnetic curvature drift, λ the wavelength perpendicular to B o and ω the frequency of the EM fields, are considered to be small. By integrating the resulting distribution function over velocity space, an explicit formula for the power absorbed by each species is obtained. To obtain an expression suitable for direct implementation in an ideal-MHD code, the electric field component parallel to the magnetostatic field is evaluated using the quasi-neutrality equation. (author) 4 refs

  1. Specially formulated foods for treating children with moderate acute malnutrition in low- and middle-income countries.

    Science.gov (United States)

    Lazzerini, Marzia; Rubert, Laura; Pani, Paola

    2013-06-21

    Moderate acute malnutrition, also called moderate wasting, affects around 10% of children under five years of age in low- and middle-income countries. There are different approaches to addressing malnutrition with prepared foods in these settings; for example, providing lipid-based nutrient supplements or blended foods, either a full daily dose or in a low dose as a complement to the usual diet. There is no definitive consensus on the most effective way to treat children with moderate acute malnutrition. To evaluate the safety and effectiveness of different types of specially formulated foods for children with moderate acute malnutrition in low- and middle-income countries, and to assess whether foods complying or not complying with specific nutritional compositions, such as the WHO technical specifications, are safe and effective. In October 2012, we searched CENTRAL, MEDLINE, LILACS, CINAHL, BIBLIOMAP, POPLINE, ZETOC, ICTRP, mRCT, and ClinicalTrials.gov. In August 2012, we searched Embase. We also searched the reference lists of relevant papers and contacted nutrition-related organisations and researchers in this field.     We planned to included any relevant randomised controlled trials (RCTs), controlled clinical trials (CCTs), controlled before-and-after studies (CBAs), and interrupted time series (ITS) that evaluated specially formulated foods for the treatment of moderate acute malnutrition in children aged between six months and five years in low- and middle-income countries. Two authors assessed trial eligibility and risk of bias, and extracted and analysed the data. We summarised dichotomous outcomes using risk ratios (RR) and continuous outcomes using mean differences (MD) with 95% confidence intervals (CI). Where appropriate, we combined data in meta-analyses using the random-effects model and assessed heterogeneity. The quality of evidence was assessed using GRADE methods. Eight randomised controlled trials, enrolling 10,037 children, met our

  2. Standard test method for graphite furnace atomic absorption spectrometric determination of lead and cadmium extracted from ceramic foodware

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers procedures for using graphite furnace atomic absorption spectroscopy (GFAAS) to quantitatively determine lead and cadmium extracted by acetic acid at room temperature from the food-contact surface of foodware. The method is applicable to food-contact surfaces composed of silicate-based materials (earthenware, glazed ceramicware, decorated ceramicware, decorated glass, and lead crystal glass) and is capable of determining lead concentrations greater than 0.005 to 0.020 g/mL and cadmium concentrations greater than 0.0005 to 0.002 g/mL, depending on instrument design. 1.2 This test method also describes quality control procedures to check for contamination and matrix interference during GFAAS analyses and a specific sequence of analytical measurements that demonstrates proper instrument operation during the time period in which sample solutions are analyzed. 1.3 Cleaning and other contamination control procedures are described in this test method. Users may modify contamination cont...

  3. Stigma moderates the associations of insight with depressed mood, low self-esteem, and low quality of life in patients with schizophrenia spectrum disorders.

    Science.gov (United States)

    Staring, A B P; Van der Gaag, M; Van den Berge, M; Duivenvoorden, H J; Mulder, C L

    2009-12-01

    Good insight into illness in patients with schizophrenia is related not only to medication compliance and high service engagement, but also to depression, low self-esteem, and low quality of life. The detrimental effects of insight pose a problem for treatment. To investigate whether the negative associations of good insight are moderated by perceived stigma. Respondents were 114 patients with schizophrenia spectrum disorders. We used Analyses of Variance (ANOVA) and Structural Equation Modeling (SEM) to test moderation. Good insight was associated with high service engagement and high compliance. Also, good insight was associated with depressed mood, low quality of life, and negative self-esteem. This association was strong when stigma was high and weak when stigma was low. SEM showed that the constrained model performed significantly worse than the unconstrained model, in which detrimental associations of insight were free to vary across stigma groups (chi(2)=19.082; df=3; plow quality of life, and negative self-esteem are moderated by stigma. Patients with good insight who do not perceive much stigmatization seem to be best off across various outcome parameters. Those with poor insight have problems with service engagement and medication compliance. Patients with good insight accompanied by stigmatizing beliefs have the highest risk of experiencing low quality of life, negative self-esteem, and depressed mood. A clinical implication is that when it is attempted to increase insight, perceived stigma should also be addressed.

  4. The effects of low to moderate alcohol consumption and binge drinking in early pregnancy on behaviour in 5-year-old children: a prospective cohort study on 1628 children

    DEFF Research Database (Denmark)

    Skogerbø, Åshild; Kesmodel, Ulrik Schiøler; Denny, Clark

    2013-01-01

    To examine the effects of low to moderate maternal alcohol consumption and binge drinking in early pregnancy on behaviour in children at the age of 5 years.......To examine the effects of low to moderate maternal alcohol consumption and binge drinking in early pregnancy on behaviour in children at the age of 5 years....

  5. Coupling continuous ultrasound-assisted extraction, preconcentration and flame atomic absorption spectrometric detection for the determination of cadmium and lead in mussel samples

    International Nuclear Information System (INIS)

    Yebra-Biurrun, M.C.; Cancela-Perez, S.; Moreno-Cid-Barinaga, A.

    2005-01-01

    Continuous ultrasound-assisted extraction has been coupled with preconcentration and flame atomic absorption spectrometry for the determination of cadmium and lead in mussel samples. Experimental designs were used for the optimisation of the leaching and preconcentration steps. The use of diluted nitric acid as extractant in the continuous mode at a flow rate of 3.5 ml min -1 and room temperature was sufficient for quantitative extraction of these trace metals. A minicolumn containing a chelating resin (Chelite P, with aminomethylphosphoric acid groups) was proved as an excellent material for the quantitative preconcentration of cadmium and lead prior to their flame atomic absorption detection. A flow injection manifold was used as interface for coupling the three analytical steps, which allowed the automation of the whole analytical process. A good precision of the whole procedure (2.0 and 2.3%), high enrichment factors (20.5 and 11.8) and a detection limit of 0.011 and 0.25 μg g -1 for cadmium and lead, respectively, were obtained for 80 mg of sample. The sample throughputs were ca. 16 and 14 samples h -1 for cadmium and lead, respectively. The accuracy of the analytical procedures was verified by using a standard reference material (BCR 278-R, mussel tissue) and the results were in good agreement with the certified values. The method was successfully applied to the determination of trace amounts of cadmium and lead in mussel samples from the coast of Galicia (NW, Spain)

  6. Low content Ag-coated poly(acrylonitrile) microspheres and graphene for enhanced microwave absorption performance epoxy composites

    Science.gov (United States)

    Zhang, Bin; Wang, Jun; Chen, Xiaocheng; Su, Xiaogang; Zou, Yi; Huo, Siqi; Chen, Wei; Wang, Junpeng

    2018-04-01

    Silver nanoparticles was uniformly anchored on the surface of hollow poly(acrylonitrile) microspheres with a facile chemical method using hydrazine hydrate as reductant. Integrating these conducting hollow spheres (PANS@Ag) with chemical reduced graphene oxide (RGO) dispersed in epoxy resin, a lightweight microwave absorber was successfully prepared with enhanced microwave absorption performance. The chemical constitution and surface morphology of as-synthesized RGO and PANS@Ag powders were characterized by XRD, XPS, FE-SEM and SAED, while the electromagnetic properties of these different proportion PANS@Ag-RGO/EP samples were analyzed through vector network analyzer (VNA). The minimum reflection loss (RL) could reach up to ‑28.1 dB at 8.8 GHz with a layer thickness of 2 mm, and the corresponding effective absorption bandwidth (RL values less than ‑10 dB) was from 7.9 GHz to 9.8 GHz. However, the dosage of PANS@Ag and RGO was merely 3 wt% and 1 wt%, respectively. As the content of PANS@Ag powders decreased to 1 wt%, the PANS@Ag-RGO/EP samples still retained effective microwave absorption performance and the optimal RL was ‑14.7 dB. The density of as-prepared absorbers was in the range of 0.49 ∼ 0.87 g cm‑3. The low content, low density and enhanced microwave absorption performance endow the hybrid composites with competitive application prospect in stealth technology field.

  7. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on the substantiation of health claims related to lactose and increase in calcium absorption leading to an increase in calcium retention (ID 668) pursuant to Article 13(1) of Regulation (EC) No 1924/2006

    DEFF Research Database (Denmark)

    Tetens, Inge

    claims in relation to lactose and increase in calcium absorption leading to an increase in calcium retention. The scientific substantiation is based on the information provided by the Member States in the consolidated list of Article 13 health claims and references that EFSA has received from Member...... States or directly from stakeholders. The food constituent that is the subject of the health claim is lactose. The Panel considers that lactose is sufficiently characterised. The claimed effect is “calcium absorption”. The target population is assumed to be the general population. The Panel notes...... between the consumption of lactose and an increase in calcium absorption leading to an increase in calcium retention....

  8. Prenatal exposure to lead in Spain: Cord blood levels and associated factors

    Energy Technology Data Exchange (ETDEWEB)

    Llop, Sabrina, E-mail: llop_sab@gva.es [Centre of Public Health Research (CSISP), Av Catalunya 21, 46020, Valencia (Spain); Carlos III Health Institute (ISCIII), 20220 Majadahonda, Madrid (Spain); CIBER de Epidemiologia y Salud Publica (CIBERESP), Doctor Aiguader 88, 8003 Barcelona (Spain); Aguinagalde, Xabier [Public Health Laboratory of Alava, Direccion de Salud Publica, Gobierno Vasco, Santiago 11, 01002, Vitoria-Gasteiz, Basque Country (Spain); Vioque, Jesus [CIBER de Epidemiologia y Salud Publica (CIBERESP), Doctor Aiguader 88, 8003 Barcelona (Spain); Universidad Miguel Hernandez, Av de Alicante KM 87, 03550, Sant Joan d' Alacant (Spain); Ibarluzea, Jesus [CIBER de Epidemiologia y Salud Publica (CIBERESP), Doctor Aiguader 88, 8003 Barcelona (Spain); Departamento de Sanidad Gobierno Vasco, Subdireccion de Salud Publica de Gipuzkoa, Avenida de Navarra 4, 20013 San Sebastian (Spain); Biodonostia, Instituto de Investigacion Biomedica, San Sebastian (Spain); Guxens, Monica [CIBER de Epidemiologia y Salud Publica (CIBERESP), Doctor Aiguader 88, 8003 Barcelona (Spain); Centre for Research of Environmental Epidemiology (CREAL), Doctor Aiguader 88, 8003 Barcelona (Spain); Municipal Institute of Medical Research (IMIM-Hospital del Mar), Doctor Aiguader 88, 8003 Barcelona (Spain); Casas, Maribel [Centre for Research of Environmental Epidemiology (CREAL), Doctor Aiguader 88, 8003 Barcelona (Spain); Municipal Institute of Medical Research (IMIM-Hospital del Mar), Doctor Aiguader 88, 8003 Barcelona (Spain); Murcia, Mario [Centre of Public Health Research (CSISP), Av Catalunya 21, 46020, Valencia (Spain); CIBER de Epidemiologia y Salud Publica (CIBERESP), Doctor Aiguader 88, 8003 Barcelona (Spain); Ruiz, Maria [Centre for Research of Environmental Epidemiology (CREAL), Doctor Aiguader 88, 8003 Barcelona (Spain); Municipal Institute of Medical Research (IMIM-Hospital del Mar), Doctor Aiguader 88, 8003 Barcelona (Spain); and others

    2011-05-01

    Introduction and Objective: Lead is a known neurotoxic. Fetuses and infants are very vulnerable to lead exposure, since their blood-brain barrier is not completely formed. Hence, there is an importance for monitoring of blood lead levels prenatally and during early infancy. The aim of this study is to evaluate the prenatal exposure to lead and its association with maternal factors in four population based mother-child cohorts in Spain. The present research was carried out within the framework of the INMA project INfancia y Medio Ambiente (Environment and Childhood). Methods: A total of 1462 pregnant women were recruited between 2004 and 2008. Lead was analyzed in a sample of cord blood by thermal decomposition, amalgation, and Atomic Absorption Spectrometry. Maternal sociodemographic, lifestyle and dietary factors were obtained by questionnaires during pregnancy. A multivariate logistic regression model was constructed. The dependent variable was a dichotomous lead level variable (detected vs no detected, i.e. {>=} vs < 2 {mu}g/dL). Results: A low percentage of cord blood samples with lead levels {>=} 2 {mu}g/dL were found (5.9%). Geometric mean and maximum were 1.06 {mu}g/dL and 19 {mu}g/dL, respectively. Smoking at the beginning of pregnancy, age, social class, weight gain during pregnancy, gravidity, and place of residence were the maternal factors associated with detectable cord blood lead levels. Mother's diet does not appear to be a determining factor of lead exposure. Nevertheless, daily intake of iron and zinc may act as a protective factor against having cord blood lead levels {>=} 2 {mu}g/dL. Conclusion: In the different regions of Spain taking part in this study, lead levels to which newborns are exposed are low. Mobilization of lead from bones may be the main contributor to the cord blood levels. - Research Highlights: {yields} Pb is a ubiquitous environmental pollutant with harmful effects on neurodevelopment. {yields} Cord blood Pb levels in

  9. Prenatal exposure to lead in Spain: Cord blood levels and associated factors

    International Nuclear Information System (INIS)

    Llop, Sabrina; Aguinagalde, Xabier; Vioque, Jesus; Ibarluzea, Jesus; Guxens, Monica; Casas, Maribel; Murcia, Mario; Ruiz, Maria

    2011-01-01

    Introduction and Objective: Lead is a known neurotoxic. Fetuses and infants are very vulnerable to lead exposure, since their blood-brain barrier is not completely formed. Hence, there is an importance for monitoring of blood lead levels prenatally and during early infancy. The aim of this study is to evaluate the prenatal exposure to lead and its association with maternal factors in four population based mother-child cohorts in Spain. The present research was carried out within the framework of the INMA project INfancia y Medio Ambiente (Environment and Childhood). Methods: A total of 1462 pregnant women were recruited between 2004 and 2008. Lead was analyzed in a sample of cord blood by thermal decomposition, amalgation, and Atomic Absorption Spectrometry. Maternal sociodemographic, lifestyle and dietary factors were obtained by questionnaires during pregnancy. A multivariate logistic regression model was constructed. The dependent variable was a dichotomous lead level variable (detected vs no detected, i.e. ≥ vs < 2 μg/dL). Results: A low percentage of cord blood samples with lead levels ≥ 2 μg/dL were found (5.9%). Geometric mean and maximum were 1.06 μg/dL and 19 μg/dL, respectively. Smoking at the beginning of pregnancy, age, social class, weight gain during pregnancy, gravidity, and place of residence were the maternal factors associated with detectable cord blood lead levels. Mother's diet does not appear to be a determining factor of lead exposure. Nevertheless, daily intake of iron and zinc may act as a protective factor against having cord blood lead levels ≥ 2 μg/dL. Conclusion: In the different regions of Spain taking part in this study, lead levels to which newborns are exposed are low. Mobilization of lead from bones may be the main contributor to the cord blood levels. - Research Highlights: → Pb is a ubiquitous environmental pollutant with harmful effects on neurodevelopment. → Cord blood Pb levels in Spanish newborn are low in

  10. Decision trees to characterise the roles of permeability and solubility on the prediction of oral absorption.

    Science.gov (United States)

    Newby, Danielle; Freitas, Alex A; Ghafourian, Taravat

    2015-01-27

    Oral absorption of compounds depends on many physiological, physiochemical and formulation factors. Two important properties that govern oral absorption are in vitro permeability and solubility, which are commonly used as indicators of human intestinal absorption. Despite this, the nature and exact characteristics of the relationship between these parameters are not well understood. In this study a large dataset of human intestinal absorption was collated along with in vitro permeability, aqueous solubility, melting point, and maximum dose for the same compounds. The dataset allowed a permeability threshold to be established objectively to predict high or low intestinal absorption. Using this permeability threshold, classification decision trees incorporating a solubility-related parameter such as experimental or predicted solubility, or the melting point based absorption potential (MPbAP), along with structural molecular descriptors were developed and validated to predict oral absorption class. The decision trees were able to determine the individual roles of permeability and solubility in oral absorption process. Poorly permeable compounds with high solubility show low intestinal absorption, whereas poorly water soluble compounds with high or low permeability may have high intestinal absorption provided that they have certain molecular characteristics such as a small polar surface or specific topology. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  11. Electromagnetically induced absorption via incoherent collisions

    International Nuclear Information System (INIS)

    Yang Xihua; Sheng Jiteng; Xiao Min

    2011-01-01

    We conduct theoretical studies on electromagnetically induced absorption via incoherent collisions in an inhomogeneously broadened ladder-type three-level system with the density-matrix approach. The effects of the collision-induced coherence decay rates as well as the probe laser field intensity on the probe field absorption are examined. It is shown that with the increase of the collisional decay rates in a moderate range, a narrow dip due to electromagnetically induced transparency superimposed on the Doppler-broadened absorption background can be turned into a narrow peak under the conditions that the probe field intensity is not very weak as compared to the pump field, which results from the enhancement of constructive interference and suppression of destructive interference between one-photon and multiphoton transition pathways. The physical origin of the collision-assisted electromagnetically induced absorption is analyzed with a power-series solution of the density-matrix equations.

  12. Thermodynamic modelling and parametric study of a low temperature vapour compression-absorption system based on modified Gouy-Stodola equation

    International Nuclear Information System (INIS)

    Jain, Vaibhav; Sachdeva, Gulshan; Kachhwaha, S.S.

    2015-01-01

    Present paper thermodynamically analyses a VCAS (vapour compression-absorption system) with carbon dioxide (compression section) and ammonia-water (absorption section) as refrigerants and determines the optimal condensing temperature of cascade condenser using modified Gouy-Stodola equation. The optimum cascade condenser temperature is found to be −13 °C for 175 kW refrigeration capacity at an evaporator temperature of −45 °C and condenser temperature of 35 °C. The optimum cascade condenser temperature maximises the overall COP, rational efficiency and minimises the total irreversibility rate of the VCAS system. The value of optimum condensing temperature and its corresponding maximum COP, and minimum irreversibility rate are discussed for a wide range of operating conditions. Further, a comparative study of TSVCS (two stage vapour compression system) used for low temperature refrigeration applications with VCAS shows that at design point, primary energy consumption is reduced by 60.6% and electrical COP is improved by 153.6% in VCAS as compared to conventional TSVCS. But the total irreversibility rate of VCAS is 38.4% higher than the TSVCS due to the use of low grade energy in vapour absorption system and hence the rational efficiency of VCAS is 14% low. - Highlights: • Optimum cascade condenser temperature with modified Gouy-Stodola law is analysed. • It maximises COP, rational efficiency and minimises total irreversibility. • 60.6% of primary energy is saved by cascaded absorption system. • Electrical COP is improved by 153.6% with cascaded absorption system

  13. Guided-wave approaches to spectrally selective energy absorption

    Science.gov (United States)

    Stegeman, G. I.; Burke, J. J.

    1987-01-01

    Results of experiments designed to demonstrate spectrally selective absorption in dielectric waveguides on semiconductor substrates are reported. These experiments were conducted with three waveguides formed by sputtering films of PSK2 glass onto silicon-oxide layers grown on silicon substrates. The three waveguide samples were studied at 633 and 532 nm. The samples differed only in the thickness of the silicon-oxide layer, specifically 256 nm, 506 nm, and 740 nm. Agreement between theoretical predictions and measurements of propagation constants (mode angles) of the six or seven modes supported by these samples was excellent. However, the loss measurements were inconclusive because of high scattering losses in the structures fabricated (in excess of 10 dB/cm). Theoretical calculations indicated that the power distribution among all the modes supported by these structures will reach its steady state value after a propagation length of only 1 mm. Accordingly, the measured loss rates were found to be almost independent of which mode was initially excited. The excellent agreement between theory and experiment leads to the conclusion that low loss waveguides confirm the predicted loss rates.

  14. Vocabulary Use by Low, Moderate, and High ASL-Proficient Writers Compared to Hearing ESL and Monolingual Speakers.

    Science.gov (United States)

    Singleton, Jenny L; Morgan, Dianne; DiGello, Elizabeth; Wiles, Jill; Rivers, Rachel

    2004-01-01

    The written English vocabulary of 72 deaf elementary school students of various proficiency levels in American Sign Language (ASL) was compared with the performance of 60 hearing English-as-a-second-language (ESL) speakers and 61 hearing monolingual speakers of English, all of similar age. Students were asked to retell "The Tortoise and the Hare" story (previously viewed on video) in a writing activity. Writing samples were later scored for total number of words, use of words known to be highly frequent in children's writing, redundancy in writing, and use of English function words. All deaf writers showed significantly lower use of function words as compared to their hearing peers. Low-ASL-proficient students demonstrated a highly formulaic writing style, drawing mostly on high-frequency words and repetitive use of a limited range of function words. The moderate- and high-ASL-proficient deaf students' writing was not formulaic and incorporated novel, low-frequency vocabulary to communicate their thoughts. The moderate- and high-ASL students' performance revealed a departure from findings one might expect based on previous studies with deaf writers and their vocabulary use. The writing of the deaf writers also differed from the writing of hearing ESL speakers. Implications for deaf education and literacy instruction are discussed, with special attention to the fact that ASL-proficient, deaf second-language learners of English may be approaching English vocabulary acquisition in ways that are different from hearing ESL learners.

  15. Neighborhood walkability moderates the association between low back pain and physical activity: A co-twin control study.

    Science.gov (United States)

    Zadro, J R; Shirley, D; Pinheiro, M B; Bauman, A; Duncan, G E; Ferreira, P H

    2017-06-01

    The aim of this study was to investigate whether neighborhood walkability moderates the association between low back pain (LBP) and physical activity (PA), using a co-twin design to control for genetics and shared environmental factors. A cross-sectional analysis was performed on 10,228 twins from the Washington State Twin Registry with available data on LBP from recruitment surveys between 2009 and 2013. LBP within the past 3months was our exposure variable. Our outcome variables were sufficient moderate or vigorous-intensity PA (MVPA, defined as at least 75min of vigorous-intensity PA, or 150min of moderate-intensity PA per week), and walking (≥150min per week). Neighborhood walkability, estimated using the commercially available Walk Score®, was our moderator variable. After controlling for the influence of genetics and shared environment, individuals reporting LBP were significantly less likely to engage in sufficient MVPA if they lived in a neighborhood with high walkability (OR=0.59, 95%CI: 0.36-0.96). There was no association between LBP and sufficient MVPA for individuals living in a neighborhood with low walkability (OR=1.27, 95%CI: 0.93-1.72), demonstrating that walkability is a significant moderator of the association between LBP and PA (interaction p=0.013). These findings were similar for the association between LBP and walking (high walkability OR=0.42, 95%CI: 0.22-0.78; low walkability OR=0.71, 95%CI: 0.46-1.12), although the interaction was not significant (p=0.700). Neighborhood walkability moderates the association between LBP and PA. Our results highlight the importance of targeting interventions promoting PA towards individuals with LBP living in a neighborhood with good walkable access to amenities. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Does CPAP treatment lead to gastroesophageal reflux in patients with moderate and severe OSA?

    Science.gov (United States)

    Ozcelik, Hatice; Kayar, Yusuf; Danalioglu, Ahmet; Arabaci, Elif; Uysal, Omer; Yakar, Fatih; Kart, Levent

    2017-03-01

    Obstructive sleep apnea (OSA) leads to upper respiratory tract obstruction, causing increased abdominal-gastric pressure and decreased lower esophageal sphincter (LES) pressure and thus gastroesophageal reflux (GER). Continuous positive airway pressure (CPAP) is known to be an effective method for OSA treatment, but its effect on GER is still controversial. There are a very few studies investigating CPAP and GER relationship and performed based on pre- and post-treatment objective parameters of GER in patients with OSA. The study investigated the effect of CPAP treatment in patients with moderate and severe OSA without GER complaints on pre- and post-treatment objective GER parameters. The study included 25 patients with respiratory disturbance indices >15 without reflux symptoms who had undergone polysomnography at sleep laboratory. Age, sex, body mass index (BMI), waist, and neck circumference of the patients were documented. DeMeester score, LES pressure, and polysomnography parameters were evaluated pre- and post-CPAP. The results were statistically evaluated, and p value CPAP phase, mean sphincter pressure was 22.2 ± 1.2 (range 8-73), and mean DeMeester score was 18 ± 15.5 (range 0.2-57). At the post-CPAP, mean sphincter pressure was 22.9 ± 1.6 (range 9-95), and mean DeMeester score was 16.3 ± 14.8 (range 0.2-55). No significant difference (p > 0.05) was found comparing pre-CPAP and post-CPAP measurements. Objective criteria show that CPAP treatment does not cause reflux in patients with OSA. Unlike studies reported in the literature, this conclusion has been reached by pre- and post-CPAP assessments.

  17. Predictive risk factors for moderate to severe hyperbilirubinemia

    Directory of Open Access Journals (Sweden)

    Gláucia Macedo de Lima

    2007-12-01

    Full Text Available Objective: to describe predictive factors for severity of neonataljaundice in newborn infants treated at the University Neonatal Clinic,highlighting maternal, obstetric and neonatal factors. Methods: Acohort retrospective study by means of review of medical charts todefine risk factors associated with moderate and severe jaundice.The cohort consisted of newborns diagnosed with indirect neonatalhyperbilirubinemia and submitted to phototherapy. Risk was classifiedas maternal, prenatal, obstetric and neonatal factors; risk estimationwas based on the odds ratio (95% confidence interval; a bi-variantmultivariate regression logistic analysis was applied to variables forp < 0.1. Results: Of 818 babies born during the studied period, 94(11% had jaundice prior to hospital discharge. Phototherapy was usedon 69 (73% patients. Predictive factors for severity were multiparity;prolonged rupture of membranes, dystocia, cephalohematoma, a lowApgar score, prematurity and small-for-date babies. Following birth,breastfeeding, sepsis, Rh incompatibility, and jaundice presentingbefore the third day of life were associated with an increased risk ofhyperbilirubinemia and the need for therapy. Conclusion: Other thanthose characteristics that are singly associated with phototherapy,we concluded that multiparity, presumed neonatal asphyxia, low birthweight and infection are the main predictive factors leading to moderateand severe jaundice in newborn infants in our neonatal unit.

  18. Electrocardiogram voltage discordance: Interpretation of low QRS voltage only in the precordial leads.

    Science.gov (United States)

    Kim, Diana H; Verdino, Ralph J

    To define clinical correlates of low voltage isolated to precordial leads on the surface electrocardiogram (ECG). Low voltage (V) on the ECG is defined as QRS Vvoltage isolated to the precordial leads with normal limb lead voltages is unclear. Twelve-lead ECGs with QRS V>5mm in one or more limb leads and voltage was found in 256 of 150,000 ECGs (~0.2%). 50.4% of patients had discordant ECGs that correlated with classic etiologies, with a higher incidence of LV dilation in those with classic etiologies than those without. Low precordial voltage is associated with classic etiologies and LV dilation. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Bulk damage and absorption in fused silica due to high-power laser applications

    Science.gov (United States)

    Nürnberg, F.; Kühn, B.; Langner, A.; Altwein, M.; Schötz, G.; Takke, R.; Thomas, S.; Vydra, J.

    2015-11-01

    Laser fusion projects are heading for IR optics with high broadband transmission, high shock and temperature resistance, long laser durability, and best purity. For this application, fused silica is an excellent choice. The energy density threshold on IR laser optics is mainly influenced by the purity and homogeneity of the fused silica. The absorption behavior regarding the hydroxyl content was studied for various synthetic fused silica grades. The main absorption influenced by OH vibrational excitation leads to different IR attenuations for OH-rich and low-OH fused silica. Industrial laser systems aim for the maximum energy extraction possible. Heraeus Quarzglas developed an Yb-doped fused silica fiber to support this growing market. But the performance of laser welding and cutting systems is fundamentally limited by beam quality and stability of focus. Since absorption in the optical components of optical systems has a detrimental effect on the laser focus shift, the beam energy loss and the resulting heating has to be minimized both in the bulk materials and at the coated surfaces. In collaboration with a laser research institute, an optical finisher and end users, photo thermal absorption measurements on coated samples of different fused silica grades were performed to investigate the influence of basic material properties on the absorption level. High purity, synthetic fused silica is as well the material of choice for optical components designed for DUV applications (wavelength range 160 nm - 260 nm). For higher light intensities, e.g. provided by Excimer lasers, UV photons may generate defect centers that effect the optical properties during usage, resulting in an aging of the optical components (UV radiation damage). Powerful Excimer lasers require optical materials that can withstand photon energy close to the band gap and the high intensity of the short pulse length. The UV transmission loss is restricted to the DUV wavelength range below 300 nm and

  20. Cognition in children does not suffer from very low lead exposure.

    Science.gov (United States)

    Minder, B; Das-Smaal, E A; Orlebeke, J F

    1998-01-01

    We studied the relationship between exposure to lead and memory and attention in children. Participants were 313 boys aged 9 to 12 years who attended special education schools in the Netherlands. Children whose possible attentional or memory problems were obviously due to causes other than lead contamination were excluded from the study. Cognition was assessed by extensive theory- based testing. Blood lead concentration was measured to assess body lead burden. Possible confounding factors that might affect blood lead level and/or cognitive functioning were assessed. Blood lead levels were higher in children with lower socioeconomic status and in children with more hand-to-mouth behavior, and varied seasonally, with higher values in spring and summer. The mean blood lead level was 44.4 microgram lead per liter blood, which is considered low. Only 2% of the children showed a slightly higher blood lead level than the American safety standard. To obtain robust measures of cognitive aspects, we performed a factor analysis. The results showed that blood lead level did not influence any of the cognitive factors. Therefore this study, despite being designed to maximize the chance of finding an effect in asymptomatic children, does not support a relationship between lead at very low doses (below 100 micrograms/liter blood) and cognition in schoolchildren.

  1. Long-term effectiveness and cost-effectiveness of high versus low-to-moderate intensity resistance and endurance exercise interventions among cancer survivors

    NARCIS (Netherlands)

    Kampshoff, C. S.; van Dongen, J. M.; van Mechelen, W.; Schep, G.; Vreugdenhil, A.; Twisk, J. W.R.; Bosmans, J. E.; Brug, J.; Chinapaw, M. J.M.; Buffart, Laurien M.

    Purpose: This study aimed to evaluate the long-term effectiveness and cost-effectiveness of high intensity (HI) versus low-to-moderate intensity (LMI) exercise on physical fitness, fatigue, and health-related quality of life (HRQoL) in cancer survivors. Methods: Two hundred seventy-seven cancer

  2. Coacervative extraction of trace lead from natural waters prior to its determination by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hagarová, Ingrid, E-mail: hagarova@fns.uniba.sk; Bujdoš, Marek; Matúš, Peter; Kubová, Jana

    2013-10-01

    In this work, a relatively simple and sensitive method for separation/preconcentration of trace lead from natural waters prior to its determination by electrothermal atomic absorption spectrometry has been proposed. The method is based on the extraction of Pb–dithizone chelate with coacervates made up of lauric acid in the presence of potassium ions and methanol. Several important factors affecting extraction efficiency such as pH, concentration of lauric acid and dithizone, ionic strength, incubation and centrifugation time were investigated and optimized. After separation of aqueous bulk solution from surfactant-rich phase, the final extract was redissolved by using 500 μl of methanol acidified with 0.2 mol l{sup −1} HNO{sub 3}. Under the optimized conditions (using initial sample volume of 10 ml), enrichment factor of 17.0, detection limit of 0.12 μg l{sup −1}, quantification limit of 0.38 μg l{sup −1}, relative standard deviation of 4.2% (for 2 μg l{sup −1} of Pb; n = 26), linearity of the calibration graph in the range of 0.5–4.0 μg l{sup −1} (with correlation coefficient better than 0.995) were achieved. The method was validated by the analysis of certified reference material (TMDA-61). Extraction recoveries for the CRM, spiked model solutions and spiked natural water samples were in the range of 91–96%. Finally, the method was applied to the separation/preconcentration and determination of trace lead in natural waters. - Highlights: • The potential of coacervates for the extraction of metal ions is examined. • No difficulties in coupling of ETAAS with the proposed CAE are observed. • Achieved preconcentration factor results in enhanced sensitivity. • Analytical performance is confirmed by the reliable determination of trace Pb. • The proposed CAE is ecofriendly and efficient.

  3. Low-level lead exposure effects on spatial reference memory and working memory in rats

    Institute of Scientific and Technical Information of China (English)

    Xinhua Yang; Ping Zhou; Yonghui Li

    2009-01-01

    BACKGROUND: Studies have demonstrated that lead exposure can result in cognitive dysfunction and behavior disorders. However, lead exposure impairments vary under different experimental conditions.OBJECTIVE: To detect changes in spatial learning and memory following low-level lead exposure in rats, in Morris water maze test under the same experimental condition used to analyze lead exposure effects on various memory types and learning processes.DESIGN AND SETTING: The experiment was conducted at the Animal Laboratory, Institute of Psychology, Chinese Academy of Science between February 2005 and March 2006. One-way analysis of variance (ANOVA) and behavioral observations were performed.MATERIALS: Sixteen male, healthy, adult, Sprague Dawley rats were randomized into normal control and lead exposure groups (n = 8).METHODS: Rats in the normal control group were fed distilled water, and those in the lead exposure group were fed 250 mL of 0.05% lead acetate once per day. At day 28, all rats performed the Morris water maze test, consisting of four phases: space navigation, probe test, working memory test, and visual cue test.MAIN OUTCOME MEASURES: Place navigation in the Morris water maze was used to evaluate spatial learning and memory, probe trials for spatial reference memory, working memory test for spatial working memory, and visual cue test for non-spatial cognitive function. Perkin-Elmer Model 300 Atomic Absorption Spectrometer was utilized to determine blood lead levels in rats.RESULTS: (1) In the working memory test, the time to reach the platform remained unchanged between the control and lead exposure groups (F(1,1) = 0.007, P = 0.935). A visible decrease in escape latencies was observed in each group (P = 0.028). However, there was no significant difference between the two groups (F(1,1) = 1.869, P = 0.193). The working memory probe test demonstrated no change between the two groups in the time spent in the target quadrant during the working memory probe test

  4. Efficient absorption of SO_2 with low-partial pressures by environmentally benign functional deep eutectic solvents

    International Nuclear Information System (INIS)

    Zhang, Kai; Ren, Shuhang; Hou, Yucui; Wu, Weize

    2017-01-01

    Graphical abstract: Environmentally benign deep eutectic solvents (DESs) based on betaine or L-carnitine with ethylene glycol were designed with a function and used to efficiently capture SO_2 with low partial pressures. - Highlights: • Deep eutectic solvents (DESs) were designed with a function to absorb low-conc. SO_2. • Betaine(Bet) and L-carnitine(L-car) with a functional group were used as H-bond acceptor. • Bet + ethylene glycol (EG) DES and L-car + EG DES are environmentally benign. • L-car + EG DES can absorb 0.644 mol SO_2 per mole L-car (0.37% SO_2). • L-car + EG DES is a promising absorbent for SO_2 capture. - Abstract: Sulfur dioxide (SO_2) emitted from the burning of fossil fuels is one of the main air contaminants. In this work, we found that environmentally benign solvents, deep eutectic solvents (DESs) could be designed with a function to absorb low-partial pressure SO_2 from simulated flue gas. Two kinds of biodegradable functional DESs based on betaine (Bet) and L-carnitine (L-car) as hydrogen bond accepters (HBA) and ethylene glycol (EG) as a hydrogen bond donor (HBD) were prepared with mole ratios of HBA to HBD from 1:3 to 1:5, and they were investigated to absorb SO_2 with different partial pressures at various temperatures. The results showed that the two DESs could absorb low-partial pressure SO_2 efficiently. SO_2 absorption capacities of the DESs with HBA/HBD mole ratio of 1:3 were 0.332 mol SO_2/mol HBA for Bet + EG DES and 0.820 mol SO_2/mol HBA for L-car + EG DES at 40 °C with a SO_2 partial pressure of 0.02 atm. In addition, the regeneration experiments demonstrated that the absorption capacities of DESs did not change after five absorption and desorption cycles. Furthermore, the absorption mechanism of SO_2 by DESs was studied by FT-IR, "1H NMR and "1"3C NMR spectra. It was found that there are strong acid–base interactions between SO_2 and −COO"− on HBA.

  5. Low and moderate doses of caffeine late in exercise improve performance in trained cyclists.

    Science.gov (United States)

    Talanian, Jason L; Spriet, Lawrence L

    2016-08-01

    The aim of the present study was to assess if low and moderate doses of caffeine delivered in a carbohydrate-electrolyte solution (CES) late in exercise improved time-trial (TT) performance. Fifteen (11 male, 4 female) cyclists (age, 22.5 ± 0.9 years; body mass, 69.3 ± 2.6 kg; peak oxygen consumption, 64.6 ± 1.9 mL·min(-1)·kg(-1)) completed 4 double-blinded randomized trials. Subjects completed 120 min of cycling at ∼60% peak oxygen consumption with 5 interspersed 120-s intervals at ∼82% peak oxygen consumption, immediately followed by 40-s intervals at 50 W. Following 80 min of cycling, subjects either ingested a 6% CES (PL), a CES with 100 mg (low dose, 1.5 ± 0.1 mg·kg body mass(-1)) of caffeine (CAF1), or a CES with 200 mg (moderate dose, 2.9 ± 0.1 mg·kg body mass(-1)) of caffeine (CAF2). Following the 120-min cycling challenge, cyclists completed a 6-kJ·kg body mass(-1) TT. There was no difference between respiratory, heart rate, glucose, free fatty acid, body mass, hematocrit, or urine specific gravity measurements between treatments. The CAF2 (26:36 ± 0:22 min:s) TT was completed faster than CAF1 (27:36 ± 0:32 min:s, p caffeine delivered late in exercise improved TT performance over the PL trial and the moderate dose (CAF2) improved performance to a greater extent than the low dose (CAF1).

  6. High-pressure Raman and optical absorption studies on lead pyroniobate (Pb2Nb2O7) and pressure-induced phase transitions

    International Nuclear Information System (INIS)

    Jayaraman, A.; Kourouklis, G.A.; Cooper, A.S.; Espinosa, G.P.

    1990-01-01

    High-pressure Raman scattering and optical absorption studies have been carried out on lead pyroniobate (Pb 2 Nb 2 O 7 ) up to 33 GPa, using a gasketed diamond anvil cell. The Raman study reveals the occurrence of two, possibly three, pressure-induced phase changes; a rather subtle change is indicated near 4.5 GPa. The transition near 13 GPa is attributed to a structural transition from the rhombohedral to the cubic pyrochlore structure. The third phase change occurs near 20 GPa. From the broad Raman feature that is observed at about 800 cm -1 , it is concluded that the system turns amorphous at pressures above 20 GPa. The amorphous phase recrystallizes to the original rhombohedral phase, on release of pressure. The broad Raman peaks of the recrystallized phase indicate a high degree of disorder in the material. Lead pyroniobate turns deep red near 30 GPa, from light yellow at ambient pressure. Semi quantitative absorption measurements show that the energy gap shifts red at a rate of 30 meV/GPa. This shift is attributed to the downward motion of the 5d (es) conduction band of Pb

  7. Automation techniques applied to systematic studies of moderator coupling

    Energy Technology Data Exchange (ETDEWEB)

    Ansell, S; Garcia, J F; Bennington, S M; Picton, D J; Broome, T [Rutherford Appleton Lab, Chilton (United Kingdom)

    2004-03-01

    We present new computation methods in which the geometry management of MCNPX input files can be automated. We demonstrate this method with respect to the target station 2 design at ISIS. The method presented is not a mathematically robust method, but by starting from a valid baseline model allows this model to be mutated in a reliable way. Those features that still need to be improved and added are discussed at the end. We use this method to show that a mixed lead/water pre-moderator gives a better neutron flux to radiation damage ratio for the coupled moderator. (orig.)

  8. Automation techniques applied to systematic studies of moderator coupling

    International Nuclear Information System (INIS)

    Ansell, S.; Garcia, J.F.; Bennington, S.M.; Picton, D.J.; Broome, T.

    2004-01-01

    We present new computation methods in which the geometry management of MCNPX input files can be automated. We demonstrate this method with respect to the target station 2 design at ISIS. The method presented is not a mathematically robust method, but by starting from a valid baseline model allows this model to be mutated in a reliable way. Those features that still need to be improved and added are discussed at the end. We use this method to show that a mixed lead/water pre-moderator gives a better neutron flux to radiation damage ratio for the coupled moderator. (orig.)

  9. Nitrogen Removal by Anammox Biofilm Column Reactor at Moderately Low Temperature

    Directory of Open Access Journals (Sweden)

    Tuty Emilia Agustina

    2017-10-01

    Full Text Available The anaerobic ammonium oxidation (anammox as a new biological approach for nitrogen removal has been considered to be more cost-effective compared with the combination of nitrification and denitrification process. However, the anammox bioreactors are mostly explored at high temperature (>300C in which temperature controlling system is fully required. This research was intended to develop and to apply anammox process for high nitrogen concentration removal at ambient temperature used for treating wastewater in tropical countries. An up-flow biofilm column reactor, which the upper part constructed with a porous polyester non-woven fabric material as a carrier to attach the anammox bacteria was operated without heating system. A maximum nitrogen removal rate (NRR of 1.05 kg-N m3 d-1 was reached in the operation days of 178 with a Total Nitrogen (TN removal efficiency of 74%. This showed the biofilm column anammox reactor was successfully applied to moderate high nitrogen removal from synthetic wastewater at moderately low temperature. Keywords: Anammox, biofilm column reactor, ambient temperature, nitrogen removal

  10. pH-Induced Modulation of One- and Two-Photon Absorption Properties in a Naphthalene-Based Molecular Probe.

    Science.gov (United States)

    Murugan, N Arul; Kongsted, Jacob; Ågren, Hans

    2013-08-13

    Presently, there is a great demand for small probe molecules that can be used for two-photon excitation microscopy (TPM)-based monitoring of intracellular and intraorganelle activity and pH. The candidate molecules should ideally possess a large two-photon absorption cross section with optical properties sensitive to pH changes. In the present work, we investigate the potential of a methoxy napthalene (MONAP) derivative for its suitability to serve as a pH sensor using TPM. Using an integrated approach rooted in hybrid quantum mechanics/molecular mechanics, the structures, dynamics, and the one- and two-photon properties of the probe in dimethylformamide solvent are studied. It is found that the protonated form is responsible for the optical property of MONAP at moderately low pH, for which the calculated pH-induced red shift is in good agreement with experiments. A 2-fold increase in the two-photon absorption cross section in the IR region of the spectrum is predicted for the moderately low pH form of the probe, suggesting that this can be a potential probe for pH monitoring of living cells. We also propose some design principles aimed at obtaining control of the absorption spectral range of the probe by structural tuning. Our work indicates that the integrated approach employed is capable of capturing the pH-induced changes in structure and optical properties of organic molecular probes and that such in silico tools can be used to draw structure-property relationships to design novel molecular probes suitable for a specific application.

  11. Impact of chronic low to moderate alcohol consumption on blood lipid and heart energy profile in acetaldehyde dehydrogenase 2-deficient mice.

    Science.gov (United States)

    Fan, Fan; Cao, Quan; Wang, Cong; Ma, Xin; Shen, Cheng; Liu, Xiang-wei; Bu, Li-ping; Zou, Yun-zeng; Hu, Kai; Sun, Ai-jun; Ge, Jun-bo

    2014-08-01

    To investigate the roles of acetaldehyde dehydrogenase 2 (ALDH2), the key enzyme of ethanol metabolism, in chronic low to moderate alcohol consumption-induced heart protective effects in mice. Twenty-one male wild-type (WT) or ALDH2-knockout (KO) mice were used in this study. In each genotype, 14 animals received alcohol (2.5%, 5% and 10% in week 1-3, respectively, and 18% in week 4-7), and 7 received water for 7 weeks. After the treatments, survival rate and general characteristics of the animals were evaluated. Serum ethanol and acetaldehyde levels and blood lipids were measured. Metabolomics was used to characterize the heart and serum metabolism profiles. Chronic alcohol intake decreased the survival rate of KO mice by 50%, and significantly decreased their body weight, but did not affect those of WT mice. Chronic alcohol intake significantly increased the serum ethanol levels in both WT and KO mice, but KO mice had significantly higher serum acetaldehyde levels than WT mice. Chronic alcohol intake significantly increased the serum HDL cholesterol levels in WT mice, and did not change the serum HDL cholesterol levels in KO mice. After chronic alcohol intake, WT and KO mice showed differential heart and serum metabolism profiles, including the 3 main energy substrate types (lipids, glucose and amino acids) and three carboxylic acid cycles. Low to moderate alcohol consumption increases HDL cholesterol levels and improves heart energy metabolism profile in WT mice but not in ALDH2-KO mice. Thus, preserved ALDH2 function is essential for the protective effect of low to moderate alcohol on the cardiovascular system.

  12. Bismuth as a general internal standard for lead in atomic absorption spectrometry.

    Science.gov (United States)

    Bechlin, Marcos A; Fortunato, Felipe M; Ferreira, Edilene C; Gomes Neto, José A; Nóbrega, Joaquim A; Donati, George L; Jones, Bradley T

    2014-06-11

    Bismuth was evaluated as internal standard for Pb determination by line source flame atomic absorption spectrometry (LS FAAS), high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) and line source graphite furnace atomic absorption spectrometry (LS GFAAS). Analysis of samples containing different matrices indicated close relationship between Pb and Bi absorbances. Correlation coefficients of calibration curves built up by plotting A(Pb)/A(Bi)versus Pb concentration were higher than 0.9953 (FAAS) and higher than 0.9993 (GFAAS). Recoveries of Pb improved from 52-118% (without IS) to 97-109% (IS, LS FAAS); 74-231% (without IS) to 96-109% (IS, HR-CS FAAS); and 36-125% (without IS) to 96-110% (IS, LS GFAAS). The relative standard deviations (n=12) were reduced from 0.6-9.2% (without IS) to 0.3-4.3% (IS, LS FAAS); 0.7-7.7% (without IS) to 0.1-4.0% (IS, HR-CS FAAS); and 2.1-13% (without IS) to 0.4-5.9% (IS, LS GFAAS). Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Intake of Fruits and Vegetables with Low-to-Moderate Pesticide Residues Is Positively Associated with Semen-Quality Parameters among Young Healthy Men123

    Science.gov (United States)

    Gaskins, Audrey J; Williams, Paige L; Mendiola, Jaime; Levine, Hagai; Hauser, Russ; Swan, Shanna H; Chavarro, Jorge E

    2016-01-01

    Background: Numerous studies have shown that occupational or environmental pesticide exposure can affect male fertility. There is less evidence, however, regarding any potentially adverse effects of pesticide residues in foods on markers of male fertility potential. Objectives: We examined the relations between fruit and vegetable intake, considering pesticide residue status, and semen quality and serum concentrations of reproductive hormones in healthy young men. Methods: The Rochester Young Men's Study is a cross-sectional study that recruited men aged 18–22 y (n = 189) in Rochester, New York. Participants completed a questionnaire, provided a semen sample, had a blood sample drawn, and underwent a physical examination at enrollment. Semen samples were analyzed for total sperm count, sperm concentration, morphology, motility, ejaculate volume, total motile count, and total normal count. Dietary intake during the previous year was assessed by a validated food-frequency questionnaire. Fruit and vegetables were categorized as having high [Pesticide Residue Burden Score (PRBS) ≥4] or low-to-moderate (PRBS vegetable intake with semen variables and reproductive hormones while adjusting for potential confounding factors. Results: The total intake of fruit and vegetables was unrelated to semen quality. However, the intake of fruit and vegetables with low-to-moderate pesticide residues was associated with a higher total sperm count and sperm concentration, whereas the intake of fruit and vegetables with high pesticide residues was unrelated to semen quality. On average, men in the highest quartile of low-to-moderate-pesticide fruit and vegetable intake (≥2.8 servings/d) had a 169% (95% CI: 45%, 400%) higher total sperm count and a 173% (95% CI: 57%, 375%) higher sperm concentration than did men in the lowest quartile (vegetables, regardless of pesticide-residue status, was not associated with reproductive hormone concentrations. Conclusions: The consumption of fruit

  14. Parity-Forbidden Transitions and Their Impact on the Optical Absorption Properties of Lead-Free Metal Halide Perovskites and Double Perovskites.

    Science.gov (United States)

    Meng, Weiwei; Wang, Xiaoming; Xiao, Zewen; Wang, Jianbo; Mitzi, David B; Yan, Yanfa

    2017-07-06

    Using density functional theory calculations, we analyze the optical absorption properties of lead (Pb)-free metal halide perovskites (AB 2+ X 3 ) and double perovskites (A 2 B + B 3+ X 6 ) (A = Cs or monovalent organic ion, B 2+ = non-Pb divalent metal, B + = monovalent metal, B 3+ = trivalent metal, X = halogen). We show that if B 2+ is not Sn or Ge, Pb-free metal halide perovskites exhibit poor optical absorptions because of their indirect band gap nature. Among the nine possible types of Pb-free metal halide double perovskites, six have direct band gaps. Of these six types, four show inversion symmetry-induced parity-forbidden or weak transitions between band edges, making them not ideal for thin-film solar cell applications. Only one type of Pb-free double perovskite shows optical absorption and electronic properties suitable for solar cell applications, namely, those with B + = In, Tl and B 3+ = Sb, Bi. Our results provide important insights for designing new metal halide perovskites and double perovskites for optoelectronic applications.

  15. A Moderate Low-Carbohydrate Low-Calorie Diet Improves Lipid Profile, Insulin Sensitivity and Adiponectin Expression in Rats

    Directory of Open Access Journals (Sweden)

    Jie-Hua Chen

    2015-06-01

    Full Text Available Calorie restriction (CR via manipulating dietary carbohydrates has attracted increasing interest in the prevention and treatment of metabolic syndrome. There is little consensus about the extent of carbohydrate restriction to elicit optimal results in controlling metabolic parameters. Our study will identify a better carbohydrate-restricted diet using rat models. Rats were fed with one of the following diets for 12 weeks: Control diet, 80% energy (34% carbohydrate-reduced and 60% energy (68% carbohydrate-reduced of the control diet. Changes in metabolic parameters and expressions of adiponectin and peroxisome proliferator activator receptor γ (PPARγ were identified. Compared to the control diet, 68% carbohydrate-reduced diet led to a decrease in serum triglyceride and increases inlow density lipoprotein-cholesterol (LDL-C, high density lipoprotein-cholesterol (HDL-C and total cholesterol; a 34% carbohydrate-reduced diet resulted in a decrease in triglycerides and an increase in HDL-cholesterol, no changes however, were shown in LDL-cholesterol and total cholesterol; reductions in HOMA-IR were observed in both CR groups. Gene expressions of adiponectin and PPARγ in adipose tissues were found proportionally elevated with an increased degree of energy restriction. Our study for the first time ever identified that a moderate-carbohydrate restricted diet is not only effective in raising gene expressions of adiponectin and PPARγ which potentially lead to better metabolic conditions but is better at improving lipid profiles than a low-carbohydrate diet in rats.

  16. Quasar Absorption Studies

    Science.gov (United States)

    Mushotzky, Richard (Technical Monitor); Elvis, Martin

    2004-01-01

    The aim of the proposal is to investigate the absorption properties of a sample of inter-mediate redshift quasars. The main goals of the project are: Measure the redshift and the column density of the X-ray absorbers; test the correlation between absorption and redshift suggested by ROSAT and ASCA data; constrain the absorber ionization status and metallicity; constrain the absorber dust content and composition through the comparison between the amount of X-ray absorption and optical dust extinction. Unanticipated low energy cut-offs where discovered in ROSAT spectra of quasars and confirmed by ASCA, BeppoSAX and Chandra. In most cases it was not possible to constrain adequately the redshift of the absorber from the X-ray data alone. Two possibilities remain open: a) absorption at the quasar redshift; and b) intervening absorption. The evidences in favour of intrinsic absorption are all indirect. Sensitive XMM observations can discriminate between these different scenarios. If the absorption is at the quasar redshift we can study whether the quasar environment evolves with the Cosmic time.

  17. Experiment of neutron multiplication in lead

    International Nuclear Information System (INIS)

    Jiang Wenmian; Chen Yuan; Liu Rong; Guo Haiping; Shen Jian

    1994-01-01

    The experiments of neutron multiplication in bulk lead have been performed with a total absorption detector (TAD). A hollow polyethylene sphere is used as neutron moderator and absorber of the TAD, which inner and outer diameters are 56 cm and 138 cm respectively. Slow neutron density in TAD is detected with a 6 Li glass scintillator. For Pb thicknesses of 5, 10, 15, 19.6 and 23.1 cm, the neutron multiplications are 1.301, 1.492, 1.599, 1.713 and 1.745 respectively. Overall experimental error is 2.7%. The calculational neutron multiplications with the 1-D ANISN code and ENDF/B-VI file are agreed with experimental ones within experimental error. Moreover, some factors of systematic error of TAD were investigated experimentally, but obvious factors have not been observed yet. (author)

  18. Applications of X-ray absorption spectroscopy and low temperature XMCD to metalloproteins

    Energy Technology Data Exchange (ETDEWEB)

    Christiansen, J.H. [Univ. of California, Davis, CA (United States). Dept. of Applied Science]|[Lawrence Berkeley National Lab., CA (United States). Energy and Environment Div.

    1996-01-01

    The author has used the extended X-ray absorption fine structure (EXAFS) and ultra-low temperature X-ray magnetic circular dichroism (XMCD) to study the environments of the metal sites in metalloproteins. EXAFS has been used to study the Zn site in spinach carbonic anhydrase. The EXAFS, in parallel with site directed mutagenesis studies, indicate that the active site Zn is in a cys-cys-his-H{sub 2}O environment, very different from the mammalian carbonic anhydrase active site. Nitrogenase, the primary enzyme in biological nitrogen fixation, contains two complex metal clusters of unique structure. EXAFS studies at the Fe and Mo K-edges of nitrogenase solutions and crystals yielded information about the various metal-metal distances in these two clusters. The author assigned 4 Fe and 3 Mo interactions >4 {angstrom}. Single crystal Mo K-edge EXAFS then found a very long Fe-Fe distance of {approximately}5.1 {angstrom}. These distances were then used to further refine the proposed crystallographic models to their highest accuracy yet. Studies were carried further by examining nitrogenas in oxidized and reduced forms--states for which there is no crystallographic information. Small structural changes were observed and an EXAFS model was put forth that attempts to deconvolute the EXAFS distances of the two metal clusters. Nitrogenase Apo I, a genetic mutant of nitrogenase which is though to contain only one of the two different metal clusters, was also examined using EXAFS. These studies showed results consistent with current models, yet the metal clusters were very disordered. Finally, ultra-low temperature methods were used to further the development of XMCD as a technique for studying biological systems. Experiments were performed on the copper in plastocyanin. Data was collected that definitively proves that the sample surface was at 0.55 {+-} 0.05 K. This result opens the door to further study of more complex biological metal clusters.

  19. A high-performance, low-cost, leading edge discriminator

    Indian Academy of Sciences (India)

    Abstract. A high-performance, low-cost, leading edge discriminator has been designed with a timing performance comparable to state-of-the-art, commercially available discrim- inators. A timing error of 16 ps is achieved under ideal operating conditions. Under more realistic operating conditions the discriminator displays a ...

  20. Optical coherence tomography and low-frequency mechanics: A moderated discussion

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, Dennis M. [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts (United States); Ruggero, Mario A. [Knowles Hearing Center, Northwestern University, Evanston, Illinois (United States)

    2015-12-31

    The following is an edited transcript of a recorded discussion session on the topics of “Optical Coherence Tomography” and “Low-Frequency Mechanics”. The discussion, moderated by the authors, took place at the 12{sup th} International Workshop on the Mechanics of Hearing held at Cape Sounio, Greece, in June 2014. All participants knew that the session was being recorded. In view of both the spontaneous nature of the discussion and the editing, however, this transcript may not represent the considered or final views of the participants, and may not represent a consensus of experts in the field. The reader is advised to consult additional independent publications.

  1. Liver Fat Scores Moderately Reflect Interventional Changes in Liver Fat Content by a Low-Fat Diet but Not by a Low-Carb Diet.

    Science.gov (United States)

    Kabisch, Stefan; Bäther, Sabrina; Dambeck, Ulrike; Kemper, Margrit; Gerbracht, Christiana; Honsek, Caroline; Sachno, Anna; Pfeiffer, Andreas F H

    2018-01-31

    Non-alcoholic fatty liver disease (NAFLD) is a common metabolic disorder all over the world, mainly being associated with a sedentary lifestyle, adiposity, and nutrient imbalance. The increasing prevalence of NAFLD accommodates similar developments for type 2 diabetes and diabetes-related comorbidities and complications. Therefore, early detection of NAFLD is an utmost necessity. Potentially helpful tools for the prediction of NAFLD are liver fat indices. The fatty liver index (FLI) and the NAFLD-liver fat score (NAFLD-LFS) have been recently introduced for this aim. However, both indices have been shown to correlate with liver fat status, but there is neither sufficient data on the longitudinal representation of liver fat change, nor proof of a diet-independent correlation between actual liver fat change and change of index values. While few data sets on low-fat diets have been published recently, low-carb diets have not been yet assessed in this context. We aim to provide such data from a highly effective short-term intervention to reduce liver fat, comparing a low-fat and a low-carb diet in subjects with prediabetes. Anthropometric measurements, magnetic resonance (MR)-based intrahepatic lipid (IHL) content, and several serum markers for liver damage have been collected in 140 subjects, completing the diet phase in this trial. Area-under-the-responder-operator-curves (AUROC) calculations as well as cross-sectional and longitudinal Spearman correlations were used. Both FLI and NAFLD-LFS predict liver fat with moderate accuracy at baseline (AUROC 0.775-0.786). These results are supported by correlation analyses. Changes in liver fat, achieved by the dietary intervention, correlate moderately with changes in FLI and NAFLD-LFS in the low-fat diet, but not in the low-carb diet. A correlation analysis between change of actual IHL content and change of single elements of the liver fat indices revealed diet-specific moderate to strong correlations between ΔIHL and

  2. Solar absorption surface panel

    Science.gov (United States)

    Santala, Teuvo J.

    1978-01-01

    A composite metal of aluminum and nickel is used to form an economical solar absorption surface for a collector plate wherein an intermetallic compound of the aluminum and nickel provides a surface morphology with high absorptance and relatively low infrared emittance along with good durability.

  3. Increase in the amount of erythrocyte delta-aminolevulinic acid dehydratase in workers with moderate lead exposure

    International Nuclear Information System (INIS)

    Fujita, H.; Sano, S.

    1982-01-01

    The amount of ALA-D in human erythrocytes was determined directly by radioimmunoassay or calculated from the restored activity assayed in the presence of zinc and dithiothreitol, and a good correlation was observed between the RIA-based and the restored activity-based amounts. The RIA-based amount of ALA-D in the blood of 10 normal individuals (blood lead levels of 5.6 +- 2.3 μg/100 ml: mean +- SD) and 19 lead-exposed workers (blood lead levels of 41.2 +- 10.2 μg/100 ml) was 54.1 +- 11.8 μg/ml blood and 92.3 +- 20.6 μg/ml blood, respectively, indicating an apparent increase of the enzyme amount in lead-exposed workers. A significant increase in the amount of erythrocyte ALA-D calculated from the restored activity in lead-exposed workers was observed even in the low blood lead level of 10-20 μg/100 ml, resulting in the range of blood lead level 20-40 μg/100 ml. No significant difference was observed in hematocrit and hemoglobin content between lead-exposed and non-exposed groups. These observations suggested that the increase of erythrocyte ALA-D in lead exposure was not due to anemia, which might result in the increase of young erythrocytes in peripheral blood. This increase in the amount of ALA-D in human erythrocytes might be a result of the function to overcome the inhibition of the enzyme in bone marrow cells during lead exposure, and these findings may throw light on the danger to human health of low-level lead toxicity. (orig.)

  4. Blood pressure hyperreactivity: an early cardiovascular risk in normotensive men exposed to low-to-moderate inorganic arsenic in drinking water.

    Science.gov (United States)

    Kunrath, Julie; Gurzau, Eugen; Gurzau, Anca; Goessler, Walter; Gelmann, Elyssa R; Thach, Thu-Trang; McCarty, Kathleen M; Yeckel, Catherine W

    2013-02-01

    Essential hypertension is associated with chronic exposure to high levels of inorganic arsenic in drinking water. However, early signs of risk for developing hypertension remain unclear in people exposed to chronic low-to-moderate inorganic arsenic. We evaluated cardiovascular stress reactivity and recovery in healthy, normotensive, middle-aged men living in an arsenic-endemic region of Romania. Unexposed (n = 16) and exposed (n = 19) participants were sampled from communities based on WHO limits for inorganic arsenic in drinking water (Water sources and urine samples were collected and analyzed for inorganic arsenic and its metabolites. Functional evaluation of blood pressure included clinical, anticipatory, cold pressor test, and recovery measurements. Blood pressure hyperreactivity was defined as a combined stress-induced change in SBP (> 20 mmHg) and DBP (>15 mmHg). Drinking water inorganic arsenic averaged 40.2 ± 30.4 and 1.0 ± 0.2 μg/l for the exposed and unexposed groups, respectively (P pressure hyperreactivity to both anticipatory stress (47.4 vs. 12.5%; P = 0.035) and cold stress (73.7 vs. 37.5%; P = 0.044). Moreover, the exposed group exhibited attenuated blood pressure recovery from stress and a greater probability of persistent hypertensive responses (47.4 vs. 12.5%; P = 0.035). Inorganic arsenic exposure increased stress-induced blood pressure hyperreactivity and poor blood pressure recovery, including persistent hypertensive responses in otherwise healthy, clinically normotensive men. Drinking water containing even low-to-moderate inorganic arsenic may act as a sympathetic nervous system trigger for hypertension risk.

  5. Bioavailability of lead in rats fed human diets

    International Nuclear Information System (INIS)

    Kostial, K.; Kello, D.

    1979-01-01

    The bioavailability of lead was studied in rats fed various baby foods (Babymix-turkey, Babymix-vegetables, Frutolino-fruit, Frutamix-bananas, Babyron-S-26, Truefood), cow's milk, bread, liver and standard rat diet. Lead absorption was determined by measuring the whole body retention of 203 Pb 6 days after a single oral application. Highest absorption values ranging from 17 to 20% were obtained in animals fed cow's milk and fruit foods. Rats on other human diets absorbed between 3 and 8% of the radioactive lead dose. Only in animals on rat diet lead absorption was below 1%. It is concluded that rats fed human diets show absorption values similar to those in humans. This might indicate that the bioavailability of lead is primarily dependent on dietary habits. This experimental model, if confirmed by further work, might be useful for obtaining preliminary data on the bioavailability of metals from various foods

  6. Childhood Maltreatment, Emotional Lability, and Alcohol Problems in Young Adults At-Risk for ADHD: Testing Moderation and Moderated Moderation.

    Science.gov (United States)

    Bunford, Nóra; Wymbs, Brian T; Dawson, Anne E; Shorey, Ryan C

    2017-01-01

    Childhood maltreatment and alcohol problems are common among young adults with attention-deficit hyperactivity disorder (ADHD). However, little is known about the degree to which maltreatment and alcohol problems are associated; potential pertinent mediating or moderating mechanisms, such as emotional lability; and whether this association varies by sex. We examined, in a sample of adults at risk for ADHD (N = 122, 37% male), the association between childhood maltreatment and alcohol problems, whether emotional lability mediated or moderated this association, and whether either role of emotional lability differed between men and women. Emotional lability moderated the association between emotional neglect and alcohol problems; maltreatment increased risk for alcohol problems for those scoring high tovery high on emotional lability, but not for those with very low-moderate levels. The association between emotional abuse and alcohol problems depended both on emotional lability and sex; emotional abuse decreased the risk for alcohol problems among men very low/low on emotional lability, but not for men who were moderate to very high on emotional lability, or for women. These findings have implications for the way in which targeting maltreatment and emotional lability may be incorporated into prevention and intervention programs to prevent alcohol problems among men and women at risk for ADHD.

  7. Estimation of lead, cadmium and nickel content by means of Atomic Absorption Spectroscopy in dry fruit bodies of some macromycetes growing in Poland. II.

    Directory of Open Access Journals (Sweden)

    Jan Grzybek

    2014-08-01

    Full Text Available The content of lead, cadmium, and nickel in dry fruit bodies of 34 species of macromyoetes collected in Poland from 72 natural babitats by means of Atomic Absorption Spectroscopy (AAS was estimated.

  8. Preconcentration, Separation and Determination of lead(II) with Methyl Thymol Blue Adsorbed on Activated Carbon Using Flame Atomic Absorption Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ensafi, Ali A.; Ghaderi, Ali R. [Isfahan University of Technology, Isfahan (Iran, Islamic Republic of)

    2008-02-15

    An on-line system for preconcentration and separation of lead(II) is presented. The method is based on the complex formation of Pb(II) with adsorbed Methyl thymol blue on activated carbon. The conditions of preparing the solid phase reagent and of quantitative recovery of Pb(II) from diluted solutions, such as acidity of aqueous phase, solid phase capacity, and flow variables were studied as well as effect of potential interfering ions. After preconcentration step, the metal ions are eluted automatically by 5 ml of 0.5 M HNO{sub 3} solution and the lead ions content was determined by flame atomic absorption spectrometry. Under the optimum conditions, the lead ions in aqueous samples were separated and preconcentrated about 1000-fold by the column. The detection limit was 0.001 μg mL{sup -1}. Lead has been determined in river and tap water samples, with recovery of 98 to 102%.

  9. Above band gap absorption spectra of the arsenic antisite defect in low temperature grown GaAs and AlGaAs

    DEFF Research Database (Denmark)

    Dankowski, S. U.; Streb, D.; Ruff, M.

    1996-01-01

    coefficients at the band gap are twice as high as for high temperature grown materials. By annealing the samples, we obtained a drastic reduced absorption coefficient below as well as above the band gap. We observed absorption changes up to 17 000 cm(-1) for LT-GaAs and 9000 cm(-1) for LT-AlGaAs taking place......Room temperature absorption spectra of low temperature molecular beam epitaxy grown GaAs (LT-GaAs) and AlGaAs (LT-AlGaAs) are reported. We performed measurements in an extended spectral range from 0.8 eV to photon energies of 2.8 eV far above the band gap. For as-grown LT-materials, the absorption...

  10. The effects of low to moderate alcohol consumption and binge drinking in early pregnancy on executive function in 5-year-old children

    DEFF Research Database (Denmark)

    Skogerbø, A; Kesmodel, Ulrik S.; Wimberley, Theresa

    2012-01-01

    Please cite this paper as: SkogerbøÅ, Kesmodel U, Wimberley T, Støvring H, Bertrand J, Landrø N, Mortensen E. The effects of low to moderate alcohol consumption and binge drinking in early pregnancy on executive function in 5-year-old children. BJOG 2012;119:1201-1210. Objective  To examine...... the effects of low to moderate maternal alcohol consumption and binge drinking in early pregnancy on children's executive functions at the age of 5 years. Design  Follow-up study. Setting  Neuropsychological testing in four Danish cities 2003-2008. Population  A cohort of 1628 women and their children sampled...... from the Danish National Birth Cohort. Methods  Participants were sampled based on maternal alcohol drinking patterns during early pregnancy. When the children were 5 years old, the parent and teacher forms of the Behaviour Rating Inventory of Executive Function (BRIEF) were completed by the mothers...

  11. The quasi deuteron model for low energy pion absorption

    International Nuclear Information System (INIS)

    Gouweloos, M.

    1986-01-01

    In this thesis pion absorption in complex nuclei is studied in the quasi-deuteron model in which the pion is absorbed on a nucleon pair in the nucleus. The mechanism is studied in the low-energy domain since then the in-medium (pi→NN) operator turns out to be of simple character. In Ch. 2 and 3 this operator is constructed and analytical expressions are derived for (pi,NN) distributions in a plane wave impulse approximation for nuclei. The results turn out to be very useful for developing insight in the possibilities inherent in the QDM and the interpretation of the results in later chapters. Ch. 4 to 6 are devoted to the more realistic distorted wave calculations. In Ch. 4 the formal framework is presented and the calculational details are discussed. Ch.5 and 6 contain the comparison to stopped pion and in-flight data respectively. In Ch. 7 the main results are summarized. (Auth.)

  12. Lifetime exposure to low doses of lead in rats: effect on selected parameters of carbohydrate metabolism.

    Science.gov (United States)

    Nováková, Jaroslava; Lukačínová, Agnesa; Lovásová, Eva; Cimboláková, Iveta; Rácz, Oliver; Ništiar, František

    2015-05-01

    The aim of the study was to assess the effects of exposure to low doses of lead dissolved in drinking water (average daily dose of 2.2 mg kg(-1) day(-1)) on selected carbohydrate metabolism parameters in 20 wistar rats. Animals were divided into two groups - control (C) (group drinking clear water) and experimental group (Pb; group exposed to low doses of lead acetate in a concentration of 100 μmol l(-1) of drinking water). In this study, we studied the biochemical parameters (glucose, haemoglobin (Hb), glycated haemoglobin (HbA1c), lactate dehydrogenase (LDH) and amylase (AMS)) in rat blood. Glucose and Hb concentration and AMS activity decreased, LDH activity increased but HbA1c concentration levels did not change in rats exposed to lead. Our results well documented that lifetime exposure to lead affected carbohydrate metabolism of rats. Some parameters like concentration of Hb as well as activities of AMS and LDH are useful markers of intoxication of rats with lead. For the evaluation of results (e.g. AMS), not only the data at the end of the experiment should be taken into account but also the entire duration of trials (i.e. more time steps) that makes results more objective should be considered. © The Author(s) 2013.

  13. First studies of lead pollution in Guanabara

    International Nuclear Information System (INIS)

    Silveira Branquinho, C.L. da.

    1973-01-01

    The main sources of direct lead intake are studied, and metal concentrations in several medium are examined. Lead was extracted by dithizone in C Cl 4 , being determined by optical spectrophotometry. 2 1 2 Pb was used as a radioactive tracer in low concentration measurements of the metal, and analysis of its 239 KeV peak was done by a Ge-Li detector. In blood samples, the metal was complexed and extracted with APDC in MIBK, being measured by flame less atomic absorption spectrophotometry. Air samples were also collected for periods of 24 hours and 90 minutes. Representative street dust samples were examined, showing a strict correlation with lead in air. It was also estimated the amount of lead in some human blood samples. (author)

  14. Charge carrier recombination channels in the low-temperature phase of organic-inorganic lead halide perovskite thin films

    Directory of Open Access Journals (Sweden)

    Christian Wehrenfennig

    2014-08-01

    Full Text Available The optoelectronic properties of the mixed hybrid lead halide perovskite CH3NH3PbI3−xClx have been subject to numerous recent studies related to its extraordinary capabilities as an absorber material in thin film solar cells. While the greatest part of the current research concentrates on the behavior of the perovskite at room temperature, the observed influence of phonon-coupling and excitonic effects on charge carrier dynamics suggests that low-temperature phenomena can give valuable additional insights into the underlying physics. Here, we present a temperature-dependent study of optical absorption and photoluminescence (PL emission of vapor-deposited CH3NH3PbI3−xClx exploring the nature of recombination channels in the room- and the low-temperature phase of the material. On cooling, we identify an up-shift of the absorption onset by about 0.1 eV at about 100 K, which is likely to correspond to the known tetragonal-to-orthorhombic transition of the pure halide CH3NH3PbI3. With further decreasing temperature, a second PL emission peak emerges in addition to the peak from the room-temperature phase. The transition on heating is found to occur at about 140 K, i.e., revealing significant hysteresis in the system. While PL decay lifetimes are found to be independent of temperature above the transition, significantly accelerated recombination is observed in the low-temperature phase. Our data suggest that small inclusions of domains adopting the room-temperature phase are responsible for this behavior rather than a spontaneous increase in the intrinsic rate constants. These observations show that even sparse lower-energy sites can have a strong impact on material performance, acting as charge recombination centres that may detrimentally affect photovoltaic performance but that may also prove useful for optoelectronic applications such as lasing by enhancing population inversion.

  15. Playing Moderately Hard to Get

    OpenAIRE

    Stephen Reysen; Iva Katzarska-Miller

    2013-01-01

    In two studies, we examined the effect of different degrees of attraction reciprocation on ratings of attraction toward a potential romantic partner. Undergraduate college student participants imagined a potential romantic partner who reciprocated a low (reciprocating attraction one day a week), moderate (reciprocating attraction three days a week), high (reciprocating attraction five days a week), or unspecified degree of attraction (no mention of reciprocation). Participants then rated thei...

  16. Protective Effects of Tinospora cordifolia on Hepatic and Gastrointestinal Toxicity Induced by Chronic and Moderate Alcoholism.

    Science.gov (United States)

    Sharma, Bhawana; Dabur, Rajesh

    2016-01-01

    Heavy alcohol intake depletes the plasma vitamins due to hepatotoxicity and decreased intestinal absorption. However, moderate alcohol intake is often thought to be healthy. Therefore, effects of chronic moderate alcohol intake on liver and intestine were studied using urinary vitamin levels. Furthermore, effects of Tinospora cordifolia water extract (TCE) (hepatoprotective) on vitamin excretion and intestinal absorption were also studied. In the study, asymptomatic moderate alcoholics (n = 12) without chronic liver disease and healthy volunteers (n = 14) of mean age 39 ± 2.2 (mean ± SD) were selected and divided into three groups. TCE treatment was performed for 14 days. The blood and urine samples were collected on Day 0 and 14 after treatment with TCE and analyzed. In alcoholics samples, a significant increase in the levels of gamma-glutamyl transferase, aspartate transaminase, alanine transaminase, Triglyceride, Cholesterol, HDL and LDL (P alcoholic samples; however, TCE intervention restored the CA and biotin levels. Vitamin metabolism biomarkers, i.e. homocysteine and xanthurenic acid, were also normalized after TCE intervention. Overall data depict that moderate alcohol intake is also hepatotoxic and decreases intestinal absorption. However, TCE treatment effectively increased the intestinal absorption and retaining power of liver that regulated alcohol-induced multivitamin deficiency. © The Author 2015. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  17. Hydrolysis Batteries: Generating Electrical Energy during Hydrogen Absorption.

    Science.gov (United States)

    Xiao, Rui; Chen, Jun; Fu, Kai; Zheng, Xinyao; Wang, Teng; Zheng, Jie; Li, Xingguo

    2018-02-19

    The hydrolysis reaction of aluminum can be decoupled into a battery by pairing an Al foil with a Pd-capped yttrium dihydride (YH 2 -Pd) electrode. This hydrolysis battery generates a voltage around 0.45 V and leads to hydrogen absorption into the YH 2 layer. This represents a new hydrogen absorption mechanism featuring electrical energy generation during hydrogen absorption. The hydrolysis battery converts 8-15 % of the thermal energy of the hydrolysis reaction into usable electrical energy, leading to much higher energy efficiency compared to that of direct hydrolysis. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Combination of dispersive liquid-liquid microextraction with flame atomic absorption spectrometry using microsample introduction for determination of lead in water samples

    International Nuclear Information System (INIS)

    Naseri, Mohammad Taghi; Hemmatkhah, Payam; Hosseini, Mohammad Reza Milani; Assadi, Yaghoub

    2008-01-01

    The dispersive liquid-liquid microextraction (DLLME) was combined with the flame atomic absorption spectrometry (FAAS) for determination of lead in the water samples. Diethyldithiophosphoric acid (DDTP), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. A new FAAS sample introduction system was employed for the microvolume nebulization of the non-flammable chlorinated organic extracts. Injection of 20 μL volumes of the organic extract into an air-acetylene flame provided very sensitive spike-like and reproducible signals. Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters include extraction and disperser solvent type as well as their volume, extraction time, salt effect, pH and amount of the chelating agent. Under the optimized conditions, the enrichment factor of 450 was obtained from a sample volume of 25.0 mL. The enhancement factor, calculated as the ratio of the slopes of the calibration graphs with and without preconcentration, which was about 1000. The calibration graph was linear in the range of 1-70 μg L -1 with a detection limit of 0.5 μg L -1 . The relative standard deviation (R.S.D.) for seven replicate measurements of 5.0 and 50 μg L -1 of lead were 3.8 and 2.0%, respectively. The relative recoveries of lead in tap, well, river and seawater samples at the spiking level of 20 μg L -1 ranged from 93.8 to 106.2%. The characteristics of the proposed method were compared with those of the liquid-liquid extraction (LLE), cloud point extraction (CPE), on-line and off-line solid-phase extraction (SPE) as well as co-precipitation, based on bibliographic data. Operation simplicity, rapidity, low cost, high enrichment factor, good repeatability, and low consumption of the extraction solvent at a microliter level are the main advantages of the proposed method

  19. Effect of Low Dose Lead (Pb) Administration on Tail Immersion Test ...

    African Journals Online (AJOL)

    olayemitoyin

    Effect of Low Dose Lead (Pb) Administration on Tail ... Acute and sub-acute effects of lead are caused by relatively large ... As such, the brain is the organ most studied in lead toxicity. ..... inflammatory Properties of Hydro-alcohol Extract of.

  20. A pilot study examining the effects of low-volume high-intensity interval training and continuous low to moderate intensity training on quality of life, functional capacity and cardiovascular risk factors in cancer survivors.

    Science.gov (United States)

    Toohey, Kellie; Pumpa, Kate L; Arnolda, Leonard; Cooke, Julie; Yip, Desmond; Craft, Paul S; Semple, Stuart

    2016-01-01

    The aim of this study was to evaluate the effects of low-volume high-intensity interval training and continuous low to moderate intensity training on quality of life, functional capacity and cardiovascular disease risk factors in cancer survivors. Cancer survivors within 24 months post-diagnosis were randomly assigned into the low-volume high-intensity interval training group ( n  = 8) or the continuous low to moderate intensity training group ( n  = 8) group for 36 sessions (12 weeks) of supervised exercise. The low-volume high-intensity interval training (LVHIIT) group performed 7 × 30 s intervals (≥85% maximal heart rate) and the continuous low to moderate intensity training (CLMIT) group performed continuous aerobic training for 20 min (≤55% maximal heart rate) on a stationary bike or treadmill. Significant improvements (time) were observed for 13 of the 23 dependent variables (ES 0.05-0.61, p  ≤ 0.05). An interaction effect was observed for six minute walk test (18.53% [32.43-4.63] ES 0.50, p  ≤ 0.01) with the LVHIIT group demonstrating greater improvements. These preliminary findings suggest that both interventions can induce improvements in quality of life, functional capacity and selected cardiovascular disease risk factors. The LVHIIT program was well tolerated by the participants and our results suggest that LVHIIT is the preferred modality to improve fitness (6MWT); it remains to be seen which intervention elicits the most clinically relevant outcomes for patients. A larger sample size with a control group is required to confirm the significance of these findings.

  1. Life Satisfaction Moderates the Effectiveness of a Play-Based Parenting Intervention in Low-Income Mothers and Toddlers

    Science.gov (United States)

    Brock, Rebecca L.; Kochanska, Grazyna; O'Hara, Michael W.; Grekin, Rebecca S.

    2015-01-01

    This multi-method multi-trait study examined moderators and mediators of change in the context of a parenting intervention. Low-income, diverse mothers of toddlers (average age 30 months; N=186, 90 girls) participated in a play-based intervention (Child-Oriented Play versus Play-as-Usual) aimed at increasing children's committed compliance and reducing opposition toward their mothers, observed in prohibition contexts, and at reducing mother-rated children's behavior problems 6 months after the intervention. Mothers’ subjective sense of life satisfaction and fulfillment during the intervention and objective ratings of psychosocial functioning by clinicians, obtained in a clinical interview were posed as moderators, and mothers’ observed power-assertive discipline immediately following the intervention was modeled as a mediator of its impact. We tested moderated mediation using structural equation modeling, with all baseline scores (prior to randomization) controlled. Mothers’ subjective sense of life satisfaction moderated the impact of the intervention, but clinicians’ ratings did not. For mothers highly satisfied with their lives, participating in Child-Oriented Play group, compared to Play-as-Usual group, led to a reduction in power-assertive discipline which, in turn, led to children's increased compliance and decreased opposition and externalizing problems. There were no effects for mothers who reported low life satisfaction. The study elucidates the causal sequence set in motion by the intervention, demonstrates the moderating role of mothers’ subjective life satisfaction, highlights limitations of clinicians’ ratings, and informs future prevention and intervention efforts to promote adaptive parenting. PMID:25860810

  2. Life Satisfaction Moderates the Effectiveness of a Play-Based Parenting Intervention in Low-Income Mothers and Toddlers.

    Science.gov (United States)

    Brock, Rebecca L; Kochanska, Grazyna; O'Hara, Michael W; Grekin, Rebecca S

    2015-10-01

    This multi-method multi-trait study examined moderators and mediators of change in the context of a parenting intervention. Low-income, diverse mothers of toddlers (average age 30 months; N = 186, 90 girls) participated in a play-based intervention (Child-Oriented Play versus Play-as-Usual) aimed at increasing children's committed compliance and reducing opposition toward their mothers, observed in prohibition contexts, and at reducing mother-rated children's behavior problems 6 months after the intervention. Mothers' subjective sense of life satisfaction and fulfillment during the intervention and objective ratings of psychosocial functioning by clinicians, obtained in a clinical interview were posed as moderators, and mothers' observed power-assertive discipline immediately following the intervention was modeled as a mediator of its impact. We tested moderated mediation using structural equation modeling, with all baseline scores (prior to randomization) controlled. Mothers' subjective sense of life satisfaction moderated the impact of the intervention, but clinicians' ratings did not. For mothers highly satisfied with their lives, participating in Child-Oriented Play group, compared to Play-as-Usual group, led to a reduction in power-assertive discipline which, in turn, led to children's increased compliance and decreased opposition and externalizing problems. There were no effects for mothers who reported low life satisfaction. The study elucidates the causal sequence set in motion by the intervention, demonstrates the moderating role of mothers' subjective life satisfaction, highlights limitations of clinicians' ratings, and informs future prevention and intervention efforts to promote adaptive parenting.

  3. Working towards accreditation by the International Standards Organization 15189 Standard: how to validate an in-house developed method an example of lead determination in whole blood by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Garcia Hejl, Carine; Ramirez, Jose Manuel; Vest, Philippe; Chianea, Denis; Renard, Christophe

    2014-09-01

    Laboratories working towards accreditation by the International Standards Organization (ISO) 15189 standard are required to demonstrate the validity of their analytical methods. The different guidelines set by various accreditation organizations make it difficult to provide objective evidence that an in-house method is fit for the intended purpose. Besides, the required performance characteristics tests and acceptance criteria are not always detailed. The laboratory must choose the most suitable validation protocol and set the acceptance criteria. Therefore, we propose a validation protocol to evaluate the performance of an in-house method. As an example, we validated the process for the detection and quantification of lead in whole blood by electrothermal absorption spectrometry. The fundamental parameters tested were, selectivity, calibration model, precision, accuracy (and uncertainty of measurement), contamination, stability of the sample, reference interval, and analytical interference. We have developed a protocol that has been applied successfully to quantify lead in whole blood by electrothermal atomic absorption spectrometry (ETAAS). In particular, our method is selective, linear, accurate, and precise, making it suitable for use in routine diagnostics.

  4. Isolation of low-molecular-weight lead-binding protein from human erythrocytes

    International Nuclear Information System (INIS)

    Raghavan, S.R.V.; Gonick, H.C.

    1977-01-01

    In blood, lead is mainly associated with erythrocytes and only a very small amount is found in plasma. Previously it was thought that the lead was bound to the erythrocyte cell membrane but more recently it has been observed that lead is bound primarily to the cell contents, ostensibly hemoglobin. In examining the lead-binding properties of normal human erythrocytes and those of lead-exposed industrial workers, we have found that, whereas lead binds only to hemoglobin in normal erythrocytes, there is also appreciable binding of lead to a low-molecular weight-protein in erythrocytes from lead-exposed workers. The synthesis of this protein may be induced by lead exposure. The 10,000 molecular weight protein may act as a storage site and mechanism for segregating lead in a non-toxic form

  5. Efficient absorption of SO{sub 2} with low-partial pressures by environmentally benign functional deep eutectic solvents

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Kai; Ren, Shuhang [State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing, 100029 (China); Hou, Yucui [Department of Chemistry, Taiyuan Normal University, Taiyuan, 030031 (China); Wu, Weize, E-mail: wzwu@mail.buct.edu.cn [State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing, 100029 (China)

    2017-02-15

    Graphical abstract: Environmentally benign deep eutectic solvents (DESs) based on betaine or L-carnitine with ethylene glycol were designed with a function and used to efficiently capture SO{sub 2} with low partial pressures. - Highlights: • Deep eutectic solvents (DESs) were designed with a function to absorb low-conc. SO{sub 2}. • Betaine(Bet) and L-carnitine(L-car) with a functional group were used as H-bond acceptor. • Bet + ethylene glycol (EG) DES and L-car + EG DES are environmentally benign. • L-car + EG DES can absorb 0.644 mol SO{sub 2} per mole L-car (0.37% SO{sub 2}). • L-car + EG DES is a promising absorbent for SO{sub 2} capture. - Abstract: Sulfur dioxide (SO{sub 2}) emitted from the burning of fossil fuels is one of the main air contaminants. In this work, we found that environmentally benign solvents, deep eutectic solvents (DESs) could be designed with a function to absorb low-partial pressure SO{sub 2} from simulated flue gas. Two kinds of biodegradable functional DESs based on betaine (Bet) and L-carnitine (L-car) as hydrogen bond accepters (HBA) and ethylene glycol (EG) as a hydrogen bond donor (HBD) were prepared with mole ratios of HBA to HBD from 1:3 to 1:5, and they were investigated to absorb SO{sub 2} with different partial pressures at various temperatures. The results showed that the two DESs could absorb low-partial pressure SO{sub 2} efficiently. SO{sub 2} absorption capacities of the DESs with HBA/HBD mole ratio of 1:3 were 0.332 mol SO{sub 2}/mol HBA for Bet + EG DES and 0.820 mol SO{sub 2}/mol HBA for L-car + EG DES at 40 °C with a SO{sub 2} partial pressure of 0.02 atm. In addition, the regeneration experiments demonstrated that the absorption capacities of DESs did not change after five absorption and desorption cycles. Furthermore, the absorption mechanism of SO{sub 2} by DESs was studied by FT-IR, {sup 1}H NMR and {sup 13}C NMR spectra. It was found that there are strong acid–base interactions between SO{sub 2} and

  6. VRLA Refined™ lead — A must for VRLA batteries. Specification and Performance

    Science.gov (United States)

    Stevenson, M. W.; Lakshmi, C. S.; Manders, J. E.; Lam, L. T.

    VRLA Refined™ lead produced and marketed by Pasminco since 1997 is a very high purity lead with guaranteed low levels of the gassing elements but with optimum bismuth content that produces oxide of finer particle size, higher acid absorption and imparts outstanding electrical performance and endurance especially under conditions of deep cycling. VRLA batteries suffer dry-out, self-discharge, negative plate capacity loss and poor cycle life unless special lead is used for the grids and active material. This paper addresses the lead used for active material.

  7. Perspective of Chinese Forest Carbon Absorption Trade Based on Low-Carbon Economy

    OpenAIRE

    Wang, Ming-gang

    2011-01-01

    The paper analyzes the basis of forest carbon trade including me feasibility of carbon absorption trade, main body, platform and standard. The purposes of capital of carbon absorption trade is introduced. Caron absorption trade capital can be used to resettle ecological migrants, absorb employment, build forest and increase fund, increase local income, enhance forest science and technology development and launch environmental proportion. The perspective of developing forest carbon absorption ...

  8. Effects of different soil remediation methods on inhibition of lead absorption and growth and quality of Dianthus superbus L.

    Science.gov (United States)

    Yang, Xiaoyu; Ma, Siyue; Li, Jianheng

    2017-12-01

    Heavy metal pollution in soil poses a serious threat to the growth of plants used in traditional Chinese medicine. Therefore, a pot experiment was conducted to study the effects of various soil remediation methods on the performance of Herba Dianthi (Dianthus superbus L.) grown on Pb-contaminated soil. The results show that inoculation of Herba Dianthi with arbuscular mycorrhizal fungi (AMF) led to a significant reduction in Pb uptake (P< 0.05), and increased root development and root-to-shoot ratio compared to untreated control plants, along with the highest content of active components. When planting with Trifolium repens, the reduction effect of Pb absorption was insignificant. Herba Dianthi showed improved growth and active ingredients, and the lowest Pb content, with AMF inoculation. The addition of EDTA decreased the growth of Herba Dianthi, but promoted the absorption of Pb. The inhibition of tumor cells was highest in E2. In conclusion, inoculation with AMF can ensure that plant lead content meets testing standards, helping to improve the quality of medicinal herbs.

  9. Relationship of moderate and low isometric lumbar extension through architectural and muscular activity variables: a cross sectional study

    International Nuclear Information System (INIS)

    Cuesta-Vargas, Antonio I; Gonzalez-Sanchez, Manuel

    2013-01-01

    No study relating the changes obtained in the architecture of erector spinae (ES) muscle were registered with ultrasound and different intensities of muscle contraction recorded by surface EMG (electromyography) on the ES muscle was found. The aim of this study was analyse the relationship in the response of the ES muscle during isometric moderate and light lumbar isometric extension considering architecture and functional muscle variables. Cross-sectional study. 46 subjects (52% men) with a group mean age of 30.4 (±7.78). The participants developed isometric lumbar extension while performing moderate and low isometric trunk and hip extension in a sitting position with hips flexed 90 degrees and the lumbar spine in neutral position. During these measurements, electromyography recordings and ultrasound images were taken bilaterally. Bilaterally pennation angle, muscle thickness, torque and muscle activation were measured. This study was developed at the human movement analysis laboratory of the Health Science Faculty of the University of Malaga (Spain). Strong and moderate correlations were found at moderate and low intensities contraction between the variable of the same intensity, with correlation values ranging from 0.726 (Torque Moderate – EMG Left Moderate) to 0.923 (Angle Left Light – Angle Right Light) (p < 0.001). This correlation is observed between the variables that describe the same intensity of contraction, showing a poor correlation between variables of different intensities. There is a strong relationship between architecture and function variables of ES muscle when describe an isometric lumbar extension at light or moderate intensity

  10. Determination of silver, bismuth, cadmium, copper, lead, and zinc in geologic materials by atomic absorption spectrometry with tricaprylylmethylammonium chloride

    Science.gov (United States)

    Viets, J.G.

    1978-01-01

    Interferences commonly encountered in the determination of silver, bismuth, cadmium, copper, lead, and zinc at crustal abundance levels are effectively eliminated using a rapid, sensitive, organic extraction technique. A potassium chlorate-hydrochloric acid digestion solubilizes the metals not tightly bound in the silicate lattice of rocks, soils, and stream sediments. The six metals are selectively extracted into a 10% Aliquat 336-MIBK organic phase in the presence of ascorbic acid and potassium iodide. Metals in the organic extract are determined by flame atomic absorption spectrometry to the 0.02-ppm level for silver, cadmium, copper, and zinc and to the 0.2-ppm level for bismuth and lead with a maximum relative standard deviation of 18.8% for known reference samples. An additional hydrofluoric acid digestion may be used to determine metals substituted in the silicate lattice.

  11. Confinement Effects in Low-Dimensional Lead Iodide Perovskite Hybrids

    NARCIS (Netherlands)

    Kamminga, Machteld E.; Fang, Honghua; Filip, Marina R.; Giustino, Feliciano; Baas, Jacobus; Blake, Graeme R.; Loi, Maria Antonietta; Palstra, Thomas T. M.

    2016-01-01

    We use a layered solution crystal growth technique to synthesize high-quality single crystals of phenylalkylammonium lead iodide organic/inorganic hybrid compounds. Single-crystal X-ray diffraction reveals low-dimensional structures consisting of inorganic sheets separated by bilayers of the organic

  12. Identification of appropriate lags and temporal resolutions for low flow indicators in the River Rhine to forecast low flows with different lead times

    NARCIS (Netherlands)

    Demirel, M.C.; Booij, Martijn J.; Hoekstra, Arjen Ysbert

    2013-01-01

    The aim of this paper is to assess the relative importance of low flow indicators for the River Rhine and to identify their appropriate temporal lag and resolution. This is done in the context of low flow forecasting with lead times of 14 and 90 days. First, the Rhine basin is subdivided into seven

  13. Composite materials with metal oxide attached to lead chalcogenide nanocrystal quantum dots with linkers

    Science.gov (United States)

    Fuke, Nobuhiro; Koposov, Alexey Y; Sykora, Milan; Hoch, Laura

    2014-12-16

    Composite materials useful for devices such as photoelectrochemical solar cells include a substrate, a metal oxide film on the substrate, nanocrystalline quantum dots (NQDs) of lead sulfide, lead selenide, and lead telluride, and linkers that attach the NQDs to the metal oxide film. Suitable linkers preserve the 1s absorption peak of the NQDs. A suitable linker has a general structure A-B-C where A is a chemical group adapted for binding to a MO.sub.x and C is a chemical group adapted for binding to a NQD and B is a divalent, rigid, or semi-rigid organic spacer moiety. Other linkers that preserve the 1s absorption peak may also be used.

  14. Who does Red Bull give wings to? Sensation seeking moderates sensitivity to subliminal advertisement.

    Science.gov (United States)

    Bustin, Gaëlle M; Jones, Daniel N; Hansenne, Michel; Quoidbach, Jordi

    2015-01-01

    This study assessed whether subliminal priming of a brand name of a drink can affect people's choices for the primed brand, and whether this effect is moderated by personality traits. Participants with different levels of sensation seeking were presented subliminally with the words Red Bull or Lde Ublr. Results revealed that being exposed to Red Bull lead on average to small increases in participants' preferences for the primed brand. However, this effect was twice as strong for participants high in sensation seeking and did not occur for participants low in sensation seeking. Going beyond previous research showing that situational factors (e.g., thirst, fatigue…) can increase people's sensitivity to subliminal advertisement, our results suggest that some dispositional factors could have the same potentiating effect. These findings highlight the necessity of taking personality into account in non-conscious persuasion research.

  15. Use of a standard meal to study iron absorption in humans

    International Nuclear Information System (INIS)

    Reddy, M.B.; Cook, J.D.

    1994-01-01

    Iron absorption varies widely between subjects and groups of subjects because of differences in iron status which markedly influence iron assimilation from the gastrointestinal tract. A small dose of isotopically labelled inorganic iron termed the reference dose (3 mg iron as FeSO 4 ) has been used extensively during the past two decades to standardize food iron absorption in human subjects and thereby eliminate the effect of differences in iron status. Recent studies from this laboratory have shown that because of the high variability of absorption from the reference dose, nonheme iron absorption from a standardized meal provides a more reliable means of standardizing absorption from regional diets. We therefore performed initial studies with a rice based meal but we found a relatively high variation in absorption from 2.0 to 4.7% that presumably reflects differences in the phytate content of rice fours. We then undertook the evaluation of meals prepared with farina, a wheat product that is available in most regions of the world. In six different studies from a farina based meal, iron absorption ranged from 3.4 to 6.5%. Nonheme iron absorption from the farina meal when evaluated in separate laboratories extensively engaged in human studies of iron absorption, ranged from 5.1 to 10.8% but when related to the FeSO 4 dose, a more consistent ratio between 0.21 to 0.26 was observed with the exception of one laboratory where a very low absorption of 1.1.% was observed. Percentage absorption from the farina based meal decreased when the iron content of the meal was increased and showed the expected facilitation of absorption when increasing amounts of ascorbic acid were added. By reducing variability and measuring iron absorption from food rather than inorganic iron, we believe that the use of this standard meal will facilitate comparison of iron absorption data obtained in laboratories throughout the world. 4 refs, 2 tabs

  16. Low ohmic multilayer contacts in lead-tin-telluride diode lasers

    International Nuclear Information System (INIS)

    Herrmann, K.; Sumpf, B.; Boehme, D.; Hannemann, M.

    1983-01-01

    The preparation and the influence of low ohmic multilayer thin film contacts of lead-salt homo- and heterolasers on the degradation of lasing parameters during recycling processes between low working temperatures and room temperatures storage are described and discussed in detail. (author)

  17. Determining the arsenic, cadmium, lead, copper and chromium contents by atomic absorption spectrometry in Pangasius fillets from Vietnam.

    Science.gov (United States)

    Molognoni, Luciano; Vitali, Luciano; Ploêncio, Leandro As; Santos, Jacson N; Daguer, Heitor

    2016-07-01

    Pangasius is a fish produced on a large scale in Vietnam and exported to many countries. Since river contamination from human activities can affect the safety of this food, fish consumption can cause exposure to potentially toxic elements for humans. The aim of this study, therefore, was to assess arsenic, cadmium, lead, copper and chromium contents by atomic absorption spectrometry in Pangasius fillet produced in the provinces of Dong Thap and Can Tho (Vietnam) and exported to Brazil. The limits of detection were: arsenic 0.5443 µg kg(-1) , cadmium 0.0040 mg kg(-1) , chromium 0.0004 mg kg(-1) , copper 0.0037 mg kg(-1) and lead 0.0284 mg kg(-1) . Analysis of 20 samples showed results below the limit of detection for arsenic, chromium and lead, while copper average concentration was 0.0234 mg kg(-1) . Cadmium average concentration was 0.0547 mg kg(-1) , with no significant difference between the two regions studied. The samples of Pangasius had no detectable concentrations of arsenic, chromium, copper and lead, and do not represent a hazard to public health. However, cadmium analysis revealed non-compliant samples, demonstrating the importance of monitoring the quality of imported Pangasius fish. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  18. Effect of low dose Lead (Pb) administration on tail immersion test ...

    African Journals Online (AJOL)

    Effect of low dose Lead (Pb) administration on tail immersion test and ... subtle decline in cognitive function, and adverse reproductive outcome at low blood Pb level. ... Twenty adult Wistar rats of both sexes (weight 150g to 200g) were used.

  19. A pre-concentration procedure using coprecipitation for determination of lead and iron in several samples using flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Saracoglu, S.; Soylak, M.; Peker, D.S. Kacar; Elci, L.; Santos, W.N.L. dos; Lemos, V.A.; Ferreira, S.L.C.

    2006-01-01

    The present paper proposes a pre-concentration procedure for determination of lead and iron in several samples by flame atomic absorption spectrometry. In it, lead(II) and iron(III) ions are coprecipitated using the violuric acid-copper(II) system as collector. Afterwards, the precipitate is dissolved with 1 M HNO 3 solution and the metal ions are determined. The optimization step was performed using factorial design involving the variables: pH, violuric acid mass (VA) and copper concentration (Cu). Using the optimized experimental conditions, the proposed procedure allows the determination these metals with detection limits of 0.18 μg L -1 for iron and 0.16 μg L -1 for lead. The effects of foreign ions on the pre-concentration procedure were also evaluated and the results demonstrated that this method could be applied for determination of iron and lead in several real samples. The proposed method was successfully applied to the analysis of seawater, urine, mineral water, soil and physiological solution samples. The concentrations of lead and iron achieved in these samples agree well with others data reported in the literature

  20. Up-cycling waste glass to minimal water adsorption/absorption lightweight aggregate by rapid low temperature sintering: optimization by dual process-mixture response surface methodology.

    Science.gov (United States)

    Velis, Costas A; Franco-Salinas, Claudia; O'Sullivan, Catherine; Najorka, Jens; Boccaccini, Aldo R; Cheeseman, Christopher R

    2014-07-01

    Mixed color waste glass extracted from municipal solid waste is either not recycled, in which case it is an environmental and financial liability, or it is used in relatively low value applications such as normal weight aggregate. Here, we report on converting it into a novel glass-ceramic lightweight aggregate (LWA), potentially suitable for high added value applications in structural concrete (upcycling). The artificial LWA particles were formed by rapidly sintering (shrinkage during sintering, density and water adsorption/absorption. The diametrical expansion could be effectively modeled via the RSM and controlled to meet a wide range of specifications; here we optimized for LWA structural concrete. The optimally designed LWA is sintered in comparatively low temperatures (825-835 °C), thus potentially saving costs and lowering emissions; it had exceptionally low water adsorption/absorption (6.1-7.2% w/wd; optimization target: 1.5-7.5% w/wd); while remaining substantially lightweight (density: 1.24-1.28 g.cm(-3); target: 0.9-1.3 g.cm(-3)). This is a considerable advancement for designing effective environmentally friendly lightweight concrete constructions, and boosting resource efficiency of waste glass flows.

  1. Moderate-resolution spectral standards from lambda 5600 to lambda 9000

    Science.gov (United States)

    Allen, Lori E.; Strom, Karen M.

    1995-01-01

    We present a grid of stellar classification spectra of moderate resolution (R approximately 1500) in the range lambda lambda 5600-9000 A, compiled from high signal-to noise spectra of 275 stars, most in the open clusters Praesepe and M67. The grid covers dwarfs from types B8 through M5, giants from G8 through M7, and subgiants from F5 through K0. We catalog atomic and molecular absorption features useful for stellar classification, and demonstrate the use of luminosity-sensitive features to distinguish between late-type dwarf and giant stars. The entire database is made available in digital format on anonymous ftp and through the World Wide Web.

  2. Decreased absorption of midazolam in the stomach due to low pH induced by co-administration of Banha-sasim-tang

    Directory of Open Access Journals (Sweden)

    Jun Hyeon Jo

    2016-08-01

    Full Text Available Objectives Banha-sasim-tang (BST, which consists of seven different herbs, is one of the most popular herbal formulae for treating gastrointestinal disorders in Eastern Asia. The commonly used herbal medicine is often co-administered with other therapeutic drugs, which raises the possibility of herb–drug interactions and may modify the clinical safety profile of therapeutic drugs. Methods We investigated the potential herb–drug interactions between BST extract and midazolam (MDZ in mice. The area under the plasma concentration-time curve (AUC of MDZ and 1ʹ-hydroxymidazolam (1ʹ-OH-MDZ was evaluated for both oral and intraperitoneal administration of MDZ, following oral administration of BST (0.5 and 1 g/kg. Results It was found that the AUC of MDZ and 1ʹ-OH-MDZ was lower in case of oral administration of MDZ. Administration of BST extract was not associated with hepatic cytochrome P450 activity. BST extract induced a strong reduction in pH and it has been reported that oral mucosal absorption of MDZ is lower at low pH. The decreased absorption rate of MDZ might be caused by the ingredients of BST and may not be related to other factors such as increased excretion of MDZ by P-glycoprotein. Conclusions The altered pharmacokinetics of midazolam caused by co-administration with BST in vivo could be attributed to a decrease in pH and subsequent reduction of MDZ absorption rate.

  3. Microwave absorptions of ultrathin conductive films and designs of frequency-independent ultrathin absorbers

    International Nuclear Information System (INIS)

    Li, Sucheng; Anwar, Shahzad; Lu, Weixin; Hang, Zhi Hong; Hou, Bo; Shen, Mingrong; Wang, Chin-Hua

    2014-01-01

    We study the absorption properties of ultrathin conductive films in the microwave regime, and find a moderate absorption effect which gives rise to maximal absorbance 50% if the sheet (square) resistance of the film meets an impedance matching condition. The maximal absorption exhibits a frequency-independent feature and takes place on an extremely subwavelength scale, the film thickness. As a realistic instance, ∼5 nm thick Au film is predicted to achieve the optimal absorption. In addition, a methodology based on metallic mesh structure is proposed to design the frequency-independent ultrathin absorbers. We perform a design of such absorbers with 50% absorption, which is verified by numerical simulations

  4. Feasibility and safety of low-flow extracorporeal CO2 removal managed with a renal replacement platform to enhance lung-protective ventilation of patients with mild-to-moderate ARDS.

    Science.gov (United States)

    Schmidt, Matthieu; Jaber, Samir; Zogheib, Elie; Godet, Thomas; Capellier, Gilles; Combes, Alain

    2018-05-10

    Extracorporeal carbon-dioxide removal (ECCO 2 R) might allow ultraprotective mechanical ventilation with lower tidal volume (VT) (ventilator-induced lung injury. This study was undertaken to assess the feasibility and safety of ECCO 2 R managed with a renal replacement therapy (RRT) platform to enable very low tidal volume ventilation of patients with mild-to-moderate acute respiratory distress syndrome (ARDS). Twenty patients with mild (n = 8) or moderate (n = 12) ARDS were included. VT was gradually lowered from 6 to 5, 4.5, and 4 ml/kg, and PEEP adjusted to reach 23 ≤ P plat  ≤ 25 cmH 2 O. Standalone ECCO 2 R (no hemofilter associated with the RRT platform) was initiated when arterial PaCO 2 increased by > 20% from its initial value. Ventilation parameters (VT, respiratory rate, PEEP), respiratory system compliance, P plat and driving pressure, arterial blood gases, and ECCO 2 R-system operational characteristics were collected during at least 24 h of very low tidal volume ventilation. Complications, day-28 mortality, need for adjuvant therapies, and data on weaning off ECCO 2 R and mechanical ventilation were also recorded. While VT was reduced from 6 to 4 ml/kg and P plat kept ventilation with moderate increase in PaCO 2 in patients with mild-to-moderate ARDS. ClinicalTrials.gov, NCT02606240. Registered on 17 November 2015.

  5. CLINICAL STUDY TO EVALUATE THE VISUAL OUTCOME AND PATIENT COMFORT IN LASIK AND PHOTOREFRACTIVE KERATECTOMY IN LOW-TO-MODERATE MYOPIC ASTIGMATISM PATIENTS

    Directory of Open Access Journals (Sweden)

    Ashok Kumar P

    2017-04-01

    Full Text Available BACKGROUND To evaluate visual outcomes following LASIK and Photorefractive Keratectomy (PRK in low-to-moderate myopia and/or myopic astigmatism in age and refractive error matched eyes. MATERIALS AND METHODS Of a total 30 patients aged ≥21 years, 20 (40 eyes underwent LASIK and 10 (20 eyes underwent PRK for low-to-moderate myopia or myopic astigmatism. LASIK was performed with the Alcon wave light 500 and PRK with the alcohol application for epithelial removal. All ablations were performed using the same excimer laser system. One surgeon operated all patients by using an excimer laser (Alcon wave light 500 system. Age and refractive error matched patients were divided in two groups. Preoperative and one year postoperative uncorrected visual acuity, best corrected visual acuity and manifest refractions were recorded to compare the outcomes of both the procedures. Outcome measures to assess the patient comfort levels in both groups include postoperative pain and quality of vision. Other outcome measures to assess the wound healing includes intraoperative complications, corneal haze and corneal reepithelialisation. RESULTS Sixty eyes of 30 patients were found matched regarding age and refractive error. In PRK group, among 10 patients, 5 (50% were males and 5 (50% were females, whereas in Lasik group, males were 12 (60% and 8 (40% were female patients. Mean preoperative MRSE was -4.06 ± 1.00 Dioptres (D for LASIK versus -4.50 ± 1.25 D for PRK. Complete flap healing was achieved by postoperative day 4 in 86.9% of LASIK eyes versus complete reepithelialisation in 92.4% of PRK eyes. Using Fisher exact test, a significantly higher percentage of LASIK eyes compared to PRK eyes achieved 20/15 or better at 1 month (35.8% vs. 17.8%, P=0.031, 3 months (69.3% vs. 49.3%, P=0.004, 6 months (79.1% vs. 59.9%, P0.50 D occurred in 12.4% of LASIK eyes within the 3- and 12-month interval versus 25.7% of PRK eyes (P=0.04. Patients in both groups were happy

  6. Bismuth as a general internal standard for lead in atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Bechlin, Marcos A.; Fortunato, Felipe M.; Ferreira, Edilene C.; Neto, José A. Gomes; Nóbrega, Joaquim A.; Donati, George L.; Jones, Bradley T.

    2014-01-01

    Highlights: • Single internal standard is commonly proposed for definite application in AAS. • Internal standard for general use in AAS techniques is original. • Bi showed efficiency as internal standard for Pb determinations by FAAS and GFAAS. • Assorted samples were analyzed and accurate results were found. - Abstract: Bismuth was evaluated as internal standard for Pb determination by line source flame atomic absorption spectrometry (LS FAAS), high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) and line source graphite furnace atomic absorption spectrometry (LS GFAAS). Analysis of samples containing different matrices indicated close relationship between Pb and Bi absorbances. Correlation coefficients of calibration curves built up by plotting A Pb /A Bi versus Pb concentration were higher than 0.9953 (FAAS) and higher than 0.9993 (GFAAS). Recoveries of Pb improved from 52–118% (without IS) to 97–109% (IS, LS FAAS); 74–231% (without IS) to 96–109% (IS, HR-CS FAAS); and 36–125% (without IS) to 96–110% (IS, LS GFAAS). The relative standard deviations (n = 12) were reduced from 0.6–9.2% (without IS) to 0.3–4.3% (IS, LS FAAS); 0.7–7.7% (without IS) to 0.1–4.0% (IS, HR-CS FAAS); and 2.1–13% (without IS) to 0.4–5.9% (IS, LS GFAAS)

  7. The effect of exercise on the absorption of inhaled human insulin in healthy volunteers

    DEFF Research Database (Denmark)

    Petersen, Astrid Heide; Kohler, Gerd; Korsatko, Stefan

    2008-01-01

    overall absorption. Aims To investigate the effect of moderate exercise on the absorption of inhaled insulin. Methods A single-centre, randomized, open-label, three-period cross-over trial was carried out in 12 nonsmoking healthy subjects. A dose of 3.5 mg inhaled human insulin was administered via...

  8. The pain, depression, disability pathway in those with low back pain: a moderation analysis of health locus of control.

    Science.gov (United States)

    Campbell, Paul; Hope, Kate; Dunn, Kate M

    2017-01-01

    Low back pain (LBP) is common, impacts on the individual and society, and is a major health concern. Psychological consequences of LBP, such as depression, are significant barriers to recovery, but mechanisms for the development of depression are less well understood. One potential mechanism is the individual's health locus of control (HLoC), that is, perception of the level of control an individual has over their health. The objective of this study is to investigate the moderation effect of HLoC on the pain-depression-disability pathway in those with LBP. The design is a nested cross-sectional analysis of two existing cohorts of patients (n=637) who had previously consulted their primary care physician about LBP. Measures were taken of HLoC, pain intensity and interference, depression, disability, and bothersomeness. Structural Equation Modeling analysis was applied to two path models that examined the pain to depression to disability pathway moderated by the HLoC constructs of Internality and Externality, respectively. Critical ratio (CR) difference tests were applied to the coefficients using pairwise comparisons. The results show that both models had an acceptable model fit and pathways were significant. CR tests indicated a significant moderation effect, with stronger pathway coefficients for depression for those who report low Internality (β 0.48), compared to those with high Internality (β 0.28). No moderation effects were found within the Externality model. HLoC Internality significantly moderates the pain-depression pathway in those with LBP, meaning that those who have a low perception of control report greater levels of depression. HLoC may signify depression among people with LBP, and could potentially be a target for intervention.

  9. Composite hydrogen-solid methane moderators

    International Nuclear Information System (INIS)

    Picton, D.; Bennington, S.; Ansell, S.; Fernandez-Garcia, J.; Broome, T.

    2004-01-01

    This paper describes the results of Monte-Carlo calculations for a coupled moderator on a low-power pulsed neutron spallation source and is part of the design study for a second target station for the ISIS spallation source. Various options were compared including hydrogen, solid methane, grooving the solid methane and compound moderators made of hydrogen in front of solid methane. To maximise the neutron current at low energies two strategies appear to emerge from the calculations. For instruments that view a large area of moderator surface a layer of hydrogen in front of a thin solid-methane moderator is optimum, giving a gain of about a factor 10 relative to the current liquid hydrogen moderator on the existing ISIS tantalum target. For instruments that only view a restricted area higher flux, corresponding to a gain of 13.5, can be achieved with the use of a single groove or re-entrant hole in the moderator. (orig.)

  10. Modeling microwave electromagnetic field absorption in muscle tissues

    Science.gov (United States)

    Felbacq, D.; Clerjon, S.; Damez, J. L.; Zolla, F.

    2002-07-01

    Absorption of electromagnetic energy in human tissues is an important issue with respect to the safety of low-level exposure. Simulation is a way to a better understanding of electromagnetic dosimetry. This letter presents a comparison between results obtained from a numerical simulation and experimental data of absorbed energy by a muscle. Simulation was done using a bidimensional double-scale homogenization scheme leading to the effective permittivity tensor. Experimental measurements were performed at 10 GHz on bovine muscle, 30 hours after slaughter, thanks to the open-ended rectangular waveguide method. Results show a good agreement between measurements and simulated data.

  11. Moderate carbohydrate, moderate protein weight loss diet reduces cardiovascular disease risk compared to high carbohydrate, low protein diet in obese adults: A randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Evans Ellen M

    2008-11-01

    Full Text Available Abstract Background To evaluate the metabolic effects of two weight loss diets differing in macronutrient composition on features of dyslipidemia and post-prandial insulin (INS response to a meal challenge in overweight/obese individuals. Methods This study was a parallel-arm randomized 4 mo weight loss trial. Adults (n = 50, 47 ± 7 y matched on BMI (33.6 ± 0.6 kg/m2, P = 0.79 consumed energy restricted diets (deficit ~500 kcal/d: PRO (1.6 g.kg-1.d-1 protein and -1.d-1 protein and > 220 g/d carbohydrate for 4 mos. Meal challenges of respective diets were utilized for determination of blood lipids and post-prandial INS and glucose response at the beginning and end of the study. Results There was a trend for PRO to lose more weight (-9.1% vs. -7.3%, P = 0.07 with a significant reduction in percent fat mass compared to CHO (-8.7% vs. -5.7%; P = 0.03. PRO also favored reductions in triacylglycerol (-34% vs. -14%; P P = 0.05; however, CHO favored reduction in LDL-C (-7% vs. +2.5%; P P P Conclusion A weight loss diet with moderate carbohydrate, moderate protein results in more favorable changes in body composition, dyslipidemia, and post-prandial INS response compared to a high carbohydrate, low protein diet suggesting an additional benefit beyond weight management to include augmented risk reduction for metabolic disease.

  12. Active feedback regulation of a Michelson interferometer to achieve zero-background absorption measurements.

    Science.gov (United States)

    Lundin, Patrik; Guan, Zuguang; Svanberg, Sune

    2011-01-20

    An active phase-controlling scheme based on a proportional-integral-derivative-controlled piezoelectric transducer is presented with the purpose of stabilizing a quasi-zero-background absorption spectrometer. A fiber-based balanced Michelson interferometer is used, and absorption due to a gas sample in one of its arms results in an increased light signal to a detector, which otherwise, thanks to destructive interference, experiences a very low light level. With the presented approach, the sensitivity of already potent absorption measurement techniques, e.g., based on modulation, could be improved even further.

  13. NTP monograph on health effects of low-level lead.

    Science.gov (United States)

    2012-06-01

    Although reductions in lead (Pb) exposure for the U.S. population have resulted in lower blood Pb levels over time, epidemiological studies continue to provide evidence of health effects at lower and lower blood Pb levels. Low-level Pb was selected for evaluation by the National Toxicology Program (NTP) because of (1) the availability of a large number of epidemiological studies of Pb, (2) a nomination by the National Institute for Occupational Safety and Health for an assessment of Pb at lower levels of exposure, and (3) public concern for effects of Pb in children and adults. This evaluation summarizes the evidence in humans and presents conclusions on health effects in children and adults associated with low-level Pb exposure as indicated by less than 10 micrograms of Pb per deciliter of blood (Monograph on Health Effects of Low-Level Lead. The document and appendices are available at http://ntp.niehs.nih.gov/go/evals. This document provides background on Pb exposure and includes a review of the primary epidemiological literature for evidence that low-level Pb is associated with neurological, immunological, cardiovascular, renal, and/or reproductive and developmental effects. The NTP Monograph presents specific conclusions for each health effect area. Overall, the NTP concludes that there is sufficient evidence that blood Pb levels Monograph on November 17-18, 2011 (http://ntp.niehs.nih.gov/go/37090.

  14. Effect of water absorption on the mechanical properties of poly(3-hydroxybutyrate)/vegetable fiber composites

    Science.gov (United States)

    Marinho, Vithória A. D.; Carvalho, Laura H.; Canedo, Eduardo L.

    2015-05-01

    The present work studies the effect of water absorption on the performance of composites of poly(3-hydroxybutyrate) (PHB) - a fully biodegradable semi-crystalline thermoplastic obtained from renewable resources through low-impact biotechnological process, biocompatible and non-toxic - and vegetable fiber from the fruit (coconut) of babassu palm tree.Water resistance is an important characteristic of structural composites, that may exposed to rain and humid environments. Both water absorption capacity (water solubility in the material) and the rate of water absorption (controlled by the diffusivity of water in the material) are important parameters. However, water absorption per se may not be the most important characteristic, insofar as the performance and applications of the compounds. It is the effect of the water content on the ultimate properties that determine the suitability of the material for applications that involve prolonged exposure to water.PHB/babassu composites with 0-20% load were prepared in an internal mixer. Two different types of babassu fibers having two different article size ranges were compounded with PHB and test specimens molded by compression. The water absorption capacity and the kinetic constant of water absorption were measured in triplicate. Mechanical properties under tension were measured for dry and moist specimens with different amounts of absorbed water.Results indicate that the performance of the composites is comparable to that of the pure matrix. Water absorption capacity increases from 0.7% (pure PHB) to 4% (PHB/20% babassu), but the water diffusivity (4.10□8 cm2/s) was found to be virtually independent of the water absorption level. Water absorption results in moderate drop in elastic modulus (10-30% at saturation, according to fiber content) but has little effect on tensile strength and elongation at break. Fiber type and initial particle size do not have a significant effect on water absorption or mechanical properties.

  15. Low to moderate alcohol consumption on serum vitamin D and other indicators of bone health in postmenopausal women in a controlled feeding study

    Science.gov (United States)

    Heavy alcohol drinking adversely affects vitamin D status and bone health. However, data from randomized, placebo-controlled trials (RCTs) on the effects of low to moderate alcohol consumption on vitamin D status and bone health in humans is unavailable. The objective of this cross-over RCT was to e...

  16. Colocalization of low-methylesterified pectins and Pb deposits in the apoplast of aspen roots exposed to lead

    International Nuclear Information System (INIS)

    Rabęda, Irena; Bilski, Henryk; Mellerowicz, Ewa J.; Napieralska, Anna; Suski, Szymon; Woźny, Adam; Krzesłowska, Magdalena

    2015-01-01

    Low-methylesterified homogalacturonans have been suggested to play a role in the binding and immobilization of Pb in CW. Using root apices of hybrid aspen, a plant with a high phytoremediation potential, as a model, we demonstrated that the in situ distribution pattern of low-methylesterified homogalacturonan, pectin epitope (JIM5-P), reflects the pattern of Pb occurrence. The region which indicated high JIM5-P level corresponded with “Pb accumulation zone”. Moreover, JIM5-P was especially abundant in cell junctions, CWs lining the intercellular spaces and the corners of intercellular spaces indicating the highest accumulation of Pb. Furthermore, JIM5-P and Pb commonly co-localized. The observations indicate that low-methylesterified homogalacturonan is the CW polymer that determines the capacity of CW for Pb sequestration. Our results suggest a promising directions for CW modification for enhancing the efficiency of plant roots in Pb accumulation, an important aspect in the phytoremediation of soils contaminated with trace metals. - Highlights: • Co-localization of low-methylesterified pectins and Pb was analysed in situ. • The pattern of Pb accumulation matched low-methylesterified pectins distribution. • Low-methylesterified pectins and Pb commonly co-localized in cell walls. • Low-methylesterified pectins revealed an important compound in Pb sequestration. • We suggest a new direction in enhancing plant efficiency for phytoremediation. - The distribution of lead in developing tissues of aspen root tips exposed to short-term lead treatment mimics the distribution of low-methylesterified pectin epitope

  17. Playing Moderately Hard to Get

    Directory of Open Access Journals (Sweden)

    Stephen Reysen

    2013-12-01

    Full Text Available In two studies, we examined the effect of different degrees of attraction reciprocation on ratings of attraction toward a potential romantic partner. Undergraduate college student participants imagined a potential romantic partner who reciprocated a low (reciprocating attraction one day a week, moderate (reciprocating attraction three days a week, high (reciprocating attraction five days a week, or unspecified degree of attraction (no mention of reciprocation. Participants then rated their degree of attraction toward the potential partner. The results of Study 1 provided only partial support for Brehm’s emotion intensity theory. However, after revising the high reciprocation condition vignette in Study 2, supporting Brehm’s emotion intensity theory, results show that a potential partners’ display of reciprocation of attraction acted as a deterrent to participants’ intensity of experienced attraction to the potential partner. The results support the notion that playing moderately hard to get elicits more intense feelings of attraction from potential suitors than playing too easy or too hard to get. Discussion of previous research examining playing hard to get is also re-examined through an emotion intensity theory theoretical lens.

  18. Multi-physical Developments for Safety Related Investigations of Low Moderated Boiling Water Reactors

    OpenAIRE

    Schlenker, Markus Thomas

    2014-01-01

    The main objective of this dissertation is the development and optimization of a low moderated boiling water reactor (BWR) core with improved fuel utilization to be incorporated in a Gen II BWR nuclear power plant. The assessment of the new core design is done by comparing it with a full MOX BWR core design regarding neutron physical and thermal-hydraulic design and safety criteria (e.g. inherent reactivity coefficients) and different sustainability parameters (e.g. conversion ratio).

  19. Multi-physical developments for safety related investigations of low moderated boiling water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Schlenker, Markus Thomas

    2014-12-19

    The main objective of this dissertation is the development and optimization of a low moderated boiling water reactor (BWR) core with improved fuel utilization to be incorporated in a Gen II BWR nuclear power plant. The assessment of the new core design is done by comparing it with a full MOX BWR core design regarding neutron physical and thermal-hydraulic design and safety criteria (e.g. inherent reactivity coefficients) and different sustainability parameters (e.g. conversion ratio).

  20. Interference scattering effects on intermediate resonance absorption at operating temperatures

    International Nuclear Information System (INIS)

    Goldstein, R.

    1975-01-01

    Resonance integrals may be accurately calculated using the intermediate resonance (IR) approximation. Results are summarized for the case of an absorber with given potential scattering cross sections and interference scattering parameter admixed with a non absorbing moderator of given cross section and located in a narrow resonance moderating medium. From the form of the IR solutions, it is possible to make some general observations about effects of interference scattering on resonance absorption. 2 figures

  1. Measurement of absorption spectrum of deuterium oxide (D2O) and its application to signal enhancement in multiphoton microscopy at the 1700-nm window

    International Nuclear Information System (INIS)

    Wang, Yuxin; Wen, Wenhui; Wang, Kai; Wang, Ke; Zhai, Peng; Qiu, Ping

    2016-01-01

    1700-nm window has been demonstrated to be a promising excitation window for deep-tissue multiphoton microscopy (MPM). Long working-distance water immersion objective lenses are typically used for deep-tissue imaging. However, absorption due to immersion water at 1700 nm is still high and leads to dramatic decrease in signals. In this paper, we demonstrate measurement of absorption spectrum of deuterium oxide (D 2 O) from 1200 nm to 2600 nm, covering the three low water-absorption windows potentially applicable for deep-tissue imaging (1300 nm, 1700 nm, and 2200 nm). We apply this measured result to signal enhancement in MPM at the 1700-nm window. Compared with water immersion, D 2 O immersion enhances signal levels in second-harmonic generation imaging, 3-photon fluorescence imaging, and third-harmonic generation imaging by 8.1, 24.8, and 24.7 times with 1662-nm excitation, in good agreement with theoretical calculation based on our absorption measurement. This suggests D 2 O a promising immersion medium for deep-tissue imaging

  2. Iron absorption in relation to iron status

    International Nuclear Information System (INIS)

    Magnusson, B.; Bjoern-Rasmussen, E.; Hallberg, L.; Rossander, L.

    1981-01-01

    The absorption from a 3 mg dose of ferrous iron was measured in 250 male subjects. The absorption was related to the log concentration of serum ferritin in 186 subjects of whom 99 were regular blood donors (r= -0.76), and to bone marrow haemosiderin grading in 52 subjects with varying iron status. The purpose was to try and establish a percentage absorption from such a dose that is representative of subjects who are borderline iron deficient. This information is necessary for food iron absorption studies in order (1) to calculate the absorption of iron from the diet at a given iron status and (2) compare the absorption of iron from different meals studied in different groups of subjects by different investigarors. The results suggest that an absorption of about 40% of a 3 mg reference dose of ferrous iron is given in a fasting state, roughly corresponds to the absorption in borderline-iron-deficient subjects. The results indicate that this 40% absorption value corresponds to a serum ferritin level of 30 μg/l and that food iron absorption in a group of subjects should be expressed preferably as the absorption corresponding to a reference-dose absorption of 45%, or possibly a serum ferritin level of 30 μg/l. (author)

  3. Unperturbed moderator brightness in pulsed neutron sources

    International Nuclear Information System (INIS)

    Batkov, K.; Takibayev, A.; Zanini, L.; Mezei, F.

    2013-01-01

    The unperturbed neutron brightness of a moderator can be defined from the number of neutrons leaving the surface of a moderator completely surrounded by a reflector. Without openings for beam extraction, it is the maximum brightness that can be theoretically achieved in a moderator. The unperturbed brightness of a cylindrical cold moderator filled with pure para-H 2 was calculated using MCNPX; the moderator dimensions were optimised, for a fixed target and reflector geometry corresponding to the present concept for the ESS spallation source. This quantity does not depend on openings for beam extraction and therefore can be used for a first-round optimisation of a moderator, before effects due to beam openings are considered. We find that such an optimisation yields to a factor of 2 increase with respect to a conventional volume moderator, large enough to accommodate a viewed surface of 12×12 cm 2 : the unperturbed neutron brightness is maximum for a disc-shaped moderator of 15 cm diameter, 1.4 cm height. The reasons for this increase can be related to the properties of the scattering cross-section of para-H 2 , to the added reflector around the exit surface in the case of a compact moderator, and to a directionality effect. This large optimisation gain in the unperturbed brightness hints towards similar potentials for the perturbed neutron brightness, in particular in conjunction with advancing the optical quality of neutron delivery from the moderator to the sample, where by Liouville theorem the brightness is conserved over the beam trajectory, except for absorption and similar type losses

  4. ICRF full wave field solution and absorption for D-T and D-3He heating scenarios

    International Nuclear Information System (INIS)

    Scharer, J.; Sund, R.

    1989-01-01

    We consider a fundamental power conservation relation, full wave solutions for fields and power absorption in moderate and high density tokamaks to third order in the gyroradius expansion. The power absorption, conductivity tensor and kinetic flux associated with the conservation relation as well as the wave differential equation are obtained. Cases examined include D-T and D- 3 He scenarios for TFTR,JET and CIT at the Fundamental and Second harmonic. Optimum single pass absorption cases for D-T operation in JET and CIT are considered as a function of the K ≡ spectrum of the antenna with an without a minority He 3 resonance. It is found that at elevated temperatures >4 keV, minority (10%) fundamental deuterium absorption is very efficient for either fast wave low or high field incidence or high field Bernstein wave incidence. We consider the effects of a 10 keV bulk and 100 keV tail helium distribution on the second harmonic absorption in a deuterium plasma for Jet parameters. In addition, scenarios with ICRF operation without attendant substantial tritium concentrations are found the fundamental (15%) and second harmonic helium (33%) heating in a the deuterium plasma. For High field operation at high density in CIT, we find a higher part of the K parallel spectrum yields good single pass absorption with a 5% minority helium concentration in D-T

  5. NO kinetics in pulsed low-pressure nitrogen plasmas studied by time resolved quantum cascade laser absorption spectroscopy

    NARCIS (Netherlands)

    Welzel, S.; Guaitella, O.; Lazzaroni, C.; Pintassilgo, C.; Rousseau, A.; Röpcke, J.

    2011-01-01

    Time-resolved quantum cascade laser absorption spectroscopy at 1897 cm-1 (5.27 µm) has been applied to study the NO(X) kinetics on the micro- and millisecond time scale in pulsed low-pressure N2/NO dc discharges. Experiments have been performed under flowing and static gas conditions to infer the

  6. Who does Red Bull give wings to? Sensation seeking moderates sensitivity to subliminal advertisement

    Directory of Open Access Journals (Sweden)

    Gaëlle Marie Bustin

    2015-06-01

    Full Text Available This study assessed whether subliminal priming of a brand name of a drink can affect people’s choices for the primed brand, and whether this effect is moderated by personality traits. Participants with different levels of sensation seeking were presented subliminally with the words Red Bull or Lde Ublr. Results revealed that being exposed to Red Bull lead on average to small increases in participants’ preferences for the primed brand. However, this effect was twice as strong for participants high in sensation seeking and did not occur for participants low in sensation seeking. Going beyond previous research showing that situational factors (e.g., thirst, fatigue… can increase people’s sensitivity to subliminal advertisement, our results suggest that some dispositional factors could have the same potentiating effect. These findings highlight the necessity of taking personality into account in non-conscious persuasion research.

  7. Low Annexin A1 expression predicts benefit from induction chemotherapy in oral cancer patients with moderate or poor pathologic differentiation grade.

    Science.gov (United States)

    Zhu, Dong-wang; Liu, Ying; Yang, Xiao; Yang, Cheng-zhe; Ma, Jie; Yang, Xi; Qiao, Jin-ke; Wang, Li-zhen; Li, Jiang; Zhang, Chen-ping; Zhang, Zhi-yuan; Zhong, Lai-ping

    2013-06-21

    The benefit of induction chemotherapy in locally advanced oral squamous cell carcinoma (OSCC) remains to be clearly defined. Induction chemotherapy is likely to be effective for biologically distinct subgroups of patients and biomarker development might lead to identification of the patients whose tumors are to respond to a particular treatment. Annexin A1 may serve as a biomarker for responsiveness to induction chemotherapy. The aim of this study was to investigate Annexin A1 expression in pre-treatment biopsies from a cohort of OSCC patients treated with surgery and post-operative radiotherapy or docetaxel, cisplatin and 5-fluorouracil (TPF) induction chemotherapy followed by surgery and post-operative radiotherapy. Furthermore we sought to assess the utility of Annexin A1 as a prognostic or predictive biomarker. Immunohistochemical staining for Annexin A1 was performed in pre-treatment biopsies from 232 of 256 clinical stage III/IVA OSCC patients. Annexin A1 index was estimated as the proportion of tumor cells (low and high, benefited from TPF induction chemotherapy as measured by distant metastasis-free survival (P=0.048, HR=0.373) as well as overall survival (P=0.078, HR=0.410). Annexin A1 can be used as a prognostic biomarker for OSCC. Patients with moderate/poorly differentiated OSCC and low Annexin A1 expression can benefit from the addition of TPF induction chemotherapy to surgery and post-operative radiotherapy. Annexin A1 expression can potentially be used as a predictive biomarker to select OSCC patients with moderate/poorly differentiated tumor who may benefit from TPF induction chemotherapy.

  8. Parenting stress and child physical health among a low-income sample: The moderating role of child anxiety.

    Science.gov (United States)

    Kidwell, Katherine M; Nelson, Timothy D; Van Dyk, Tori

    2015-11-01

    This study examined child anxiety as a potential moderator of the relationship between parenting stress and child physical health. Low-income youth (N = 109, M = 9.51 years old) and their parents completed measures of anxiety, health-related quality of life, and parenting stress in an outpatient clinic. As an objective measure of physical health, medical service utilization was extracted from medical records. Parenting stress was associated significantly with worse health-related quality of life and higher service utilization. Child anxiety moderated the relationship between stress and health. Health psychologists should target both family stress and child anxiety in promoting better health outcomes among low-income families. © The Author(s) 2013.

  9. Retail jobs in the Netherlands: low pay in a context of long-term wage moderation

    NARCIS (Netherlands)

    van Klaveren, M.; Salverda, W.; Tijdens, K.

    2009-01-01

    Wage moderation has been at the heart of the Netherlands' model of socio-economic governance since the 1980s. Low-paid employment has grown significantly, lower wages being constrained by declining minimum wages. Lagging incomes and consumption have depressed demand in retail, whose workforce -

  10. Frenkel defect absorption on dislocations and dislocation discharge rate. Modeling determination of the absorption zone

    International Nuclear Information System (INIS)

    Mikhlin, Eh.Ya.

    1988-01-01

    A situation connected with the fact that evaluations of dislocation discharge strength which somehow or other are based on the elasticity theory in the dislocation nucleus or near it, do not lead to results complying with experimental data, is discussed. Bases of the alternative approach to this problem consisting in direct investigation into the process of Frenkel defect absorption on dislocation by its computerized simulation at the microscopic level are also presented. Methods of investigation and results are described using α dislocation in iron-alpha as an example. The concept of zones of vacancy and interstitial atom absorption on dislocation is discussed. It is shown that a spontaneous transition, performed by any of these defects near a dislocation is not always identical to absorption and usually appears to be only a part of a multistage process leading to the defect disappearance. Potential relief characteristics for vacancy movement near the dislocation are found. An area wide enough in a transverse direction is found around the dislocation. Vacncies reaching this area can be easily transported to places of their disappearance. Therefore the vacancy entry to this area is equivalent to the absorption. the procedure of simulating the atomic structure of a crystallite containing a dislocation with a step is described. Positions from which these defects perform spontaneous transitions, reaching the disappearance places are found on the dislocation near the step

  11. Low blood flow at onset of moderate intensity exercise does not limit muscle oxygen uptake

    DEFF Research Database (Denmark)

    Nyberg, Michael Permin; Mortensen, Stefan Peter; Saltin, Bengt

    2010-01-01

    The effect of low blood flow at onset of moderate intensity exercise on the rate of rise in muscle oxygen uptake was examined. Seven male subjects performed a 3.5 minute one-legged knee-extensor exercise bout (24+/-1 (+/-S.D.) W) without (CON) and with (double blockade; DB) arterial infusion of i....... Additionally, prostanoids and/or NO appear to play important roles in elevating skeletal muscle blood flow in the initial phase of exercise. Key words: Oxygen delivery, oxygen extraction, nitric oxide, prostanoids.......The effect of low blood flow at onset of moderate intensity exercise on the rate of rise in muscle oxygen uptake was examined. Seven male subjects performed a 3.5 minute one-legged knee-extensor exercise bout (24+/-1 (+/-S.D.) W) without (CON) and with (double blockade; DB) arterial infusion...... of inhibitors of nitric oxide synthase (NOS; L-NMMA) and cyclooxygenase (COX; indomethacin) in order to inhibit the synthesis of nitric oxide (NO) and prostanoids, respectively.. Leg blood flow and leg oxygen delivery throughout exercise was 25-50 % lower (P

  12. How to take absorptive surfaces into account when designing outdoor sound reinforcement systems

    DEFF Research Database (Denmark)

    Rasmussen, Karsten bo

    1996-01-01

    When sound reinforcement systems are used outdoors, absorptive surfaces are usually present along the propagation path of the sound. This may lead to a very significant colouration of the spectrum received by the audience. The colouration depends on the location and directivity of the loudspeaker......, the nature of the absorptive surface (eg grass) and the location of the audience. It is discussed how this effect may be calculated and numerical examples are shown. The results show a significant colouration and attenuation of the sound due to grass-covered surfaces....

  13. Thiamine absorption is not compromised in folate-deficient rats

    International Nuclear Information System (INIS)

    Walzem, R.L.; Clifford, A.J.

    1988-01-01

    Thiamine absorption and excretion were assessed in rats with severe folate deficiency (FD) by determining the fate of oral 3 H-labeled and intravenous 14 C-labeled thiamine over a 6-h test period. Thiamine status was evaluated in these same rats by measuring transketolase activity levels of blood before (TKA) and after (TPPE) addition of thiamine pyrophosphate to the incubation mixture of the assay procedure. Two additional experiments assessed active transport of thiamine and the effect of dietary succinylsulfathiazole (SST) on TKA and TPPE in rats with moderate FD. Intestinal absorption in general and thiamine absorption in particular and thiamine status were unaltered in rats with severe FD. Inanition associated with severe FD may impair thiamine status. Thiamine absorption by active transport was not compromised in FD, and dietary succinylsulfathiazole did not affect thiamine status

  14. Lead poisoning: The invisible disease

    Science.gov (United States)

    Friend, Milton

    1989-01-01

    Lead poisoning is an intoxication resulting from absorption of hazardous levels of lead into body tissues. Lead pellets from shot shells, when ingested, are the most common source of lead poisoning in migratory birds. Other far less common sources include lead fishing sinkers, mine wastes, paint pigments, bullets, and other lead objects that are swallowed.

  15. Preconcentration of lead using solidification of floating organic drop and its determination by electrothermal atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Mahmoud Chamsaz

    2013-07-01

    Full Text Available A simple microextraction method based on solidification of a floating organic drop (SFOD was developed for preconcentration of lead prior to its determination by electrothermal atomic absorption spectrometry (ETAAS. Ammonium pyrolidinedithiocarbamate (APDC was used as complexing agent, and the formed complex was extracted into a 20 μL of 1-undecanol. The extracted complex was diluted with ethanol and injected into a graphite furnace. An orthogonal array design (OAD with OA16 (45 matrix was employed to study the effects of different parameters such as pH, APDC concentration, stirring rate, sample solution temperature and the exposure time on the extraction efficiency. Under the optimized experimental conditions the limit of detection (based on 3 s and the enhancement factor were 0.058 μg L−1 and 113, respectively. The relative standard deviation (RSD for 8 replicate determinations of 1 μg L−1 of Pb was 8.8%. The developed method was validated by the analysis of certified reference materials and was successfully applied to the determination of lead in water and infant formula base powder samples.

  16. 40 CFR Appendix B to Part 80 - Test Methods for Lead in Gasoline

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test Methods for Lead in Gasoline B... in Gasoline Method 1—Standard Method Test for Lead in Gasoline by Atomic Absorption Spectrometry 1. Scope. 1.1. This method covers the determination of the total lead content of gasoline. The procedure's...

  17. Low-dose x-ray phase-contrast and absorption CT using equally sloped tomography

    International Nuclear Information System (INIS)

    Fahimian, Benjamin P; Miao Jianwei; Mao Yu; Cloetens, Peter

    2010-01-01

    Tomographic reconstruction from undersampled and noisy projections is often desirable in transmission CT modalities for purposes of low-dose tomography and fast acquisition imaging. However under such conditions, due to the violation of the Nyquist sampling criteria and the presence of noise, reconstructions with acceptable accuracy may not be possible. Recent experiments in transmission electron tomography and coherent diffraction microscopy have shown that the technique of equally sloped tomography (EST), an exact tomographic method utilizing an oversampling iterative Fourier-based reconstruction, provides more accurate image reconstructions when the number of projections is significantly undersampled relative to filtered back projection and algebraic iterative methods. Here we extend this technique by developing new reconstruction algorithms which allow for the incorporation of advanced mathematical regularization constraints, such as the nonlocal means total variational model, in a manner that is consistent with experimental projections. We then evaluate the resulting image quality of the developed algorithm through simulations and experiments at the European Synchrotron Radiation Facility on image quality phantoms using the x-ray absorption and phase contrast CT modalities. Both our simulation and experimental results have indicated that the method can reduce the number of projections by 60-75% in parallel beam modalities, while achieving comparable or better image quality than the conventional reconstructions. As large-scale and compact synchrotron radiation facilities are currently under rapid development worldwide, the implementation of low-dose x-ray absorption and phase-contrast CT can find broad applications in biology and medicine using these advanced x-ray sources.

  18. Effect of iron status on iron absorption in different habitual meals in young south Indian women

    Directory of Open Access Journals (Sweden)

    Suneeta Kalasuramath

    2013-01-01

    Full Text Available Background & objectives: Iron deficiency (ID affects a large number of women in India. An inverse relationship exists between iron (Fe status and Fe absorption. Dietary inhibitory and enhancing factors exert a profound influence on bioavailability of Fe. Although the current recommended dietary allowance (RDA for Fe is based on 8 per cent bioavailability, it is not clear if this holds good for the usual highly inhibitory Indian diet matrix. This study was aimed to determine Fe absorption from several habitually consumed south Indian food and to evaluate the interaction of Fe status with absorption. Methods: Four Fe absorption studies were performed on 60 apparently healthy young women, aged 18-35 years. Based on blood biochemistry, 45 of them were ID and 15 were iron replete (IR. The habitual meals assessed were rice, millet and wheat based meals in the ID subjects and rice based meal alone in the IR subjects. Each subject received the test meal labelled with 3 mg of [57] Fe and Fe absorption was measured based on erythrocyte incorporation of isotope label 14 days following administration. Results: Mean fractional Fe absorption from the rice, wheat and millet based meals in the ID subjects were 8.3, 11.2 and 4.6 per cent, respectively. Fe absorption from the rice-based meals was 2.5 per cent in IR subjects. Interpretation & conclusions: Fe absorption is dictated by Fe status from low bioavailability meals. Millet based meals have the lowest bioavailability, while the rice and wheat based meals had moderate to good bioavailability. In millet based meals, it is prudent to consider ways to improve Fe absorption.

  19. Organic palladium and palladium-magnesium chemical modifiers in direct determination of lead in fractions from distillation of crude oil by electrothermal atomic absorption analysis

    Science.gov (United States)

    Kowalewska, Zofia; Bulska, Ewa; Hulanicki, Adam

    1999-05-01

    Platinum reforming catalysts are easily poisoned by increased levels of lead, therefore a sensitive atomic absorption spectrometric procedure for lead determination in fractions from crude oil distillation was developed. Lead was present in organic form in the samples analysed therefore the behaviour of various lead compounds (Pb-alkylarylsulphonate, Pb-4-cyclohexanobutyrate, tetraethyllead, Pb in fuel oil) was studied. The best procedure for the determination of lead in different petroleum products, including those containing asphaltenes includes a pretreatment with iodine and methyltrioctylammonium chloride, followed by the use of an organic Pd-Mg modifier. Under these conditions an effective matrix removal is possible at a pyrolysis temperature up to approximately 1100°C and the behaviour of lead present in different forms is unified. The characteristic mass is 11-12 pg Pb, corresponding to a detection limit of 0.25 ng g -1 for 20 μl sample solution. This can be lowered by multiple injection.

  20. The effects of low to moderate alcohol consumption and binge drinking in early pregnancy on selective and sustained attention in 5-year-old children

    DEFF Research Database (Denmark)

    Underbjerg, Mette; Kesmodel, Ulrik S.; Landrø, Nils Inge

    2012-01-01

    Please cite this paper as: Underbjerg M, Kesmodel U, Landrø N, Bakketeig L, Grove J, Wimberley T, Kilburn T, Svaerke C, Thorsen P, Mortensen E. The effects of low to moderate alcohol consumption and binge drinking in early pregnancy on selective and sustained attention in 5-year-old children. BJOG...... 2012;119:1211-1221. Objective  The aim was to examine the effects of low to moderate maternal alcohol consumption and binge drinking in early pregnancy on children's attention at 5 years of age. Design  Prospective follow-up study. Setting  Neuropsychological testing in four Danish cities 2003......-2008. Population  A cohort of 1628 women and their children sampled from the Danish National Birth Cohort. Methods  Participants were sampled based on maternal alcohol consumption during pregnancy. At 5 years of age, the children were tested with the recently developed Test of Everyday Attention for Children...

  1. Tolerance and efficacy of a low dose of the calcimimetic agent cinacalcet in controlling moderate to severe secondary hyperparathyroidism in hemodialysis patients.

    Science.gov (United States)

    Bashir, Salah O; Omer, Hayder A; Aamer, Mahmoud A; Somialy, Rashid; Morsy, Mohamed D

    2015-11-01

    Secondary hyperparathyroidism is almost a constant feature in chronic kidney disease (CKD) patients maintained on hemodialysis (HD). Calcimimetic agents appear to offer an alternative to surgery in controlling secondary hyperparathyroidism in these patients. Recent studies provide conflicting data on the benefits, efficacy and tolerance of cinacalcet as first-line therapy for the treatment of secondary hyperparathyroidism in CKD. This study was designed to investigate the efficacy and tolerance of a low dose of the calcimimetic agent cinacalcet in patients on long-term HD having moderate to severe secondary hyperparathyroidism. Twenty five adult male patients on HD for more than three years were included in the study. All had moderate to severe secondary hyperparathyroidism with serum intact parathyroid hormone (iPTH) >50 pmol/L, resistant to conventional treatment. We used the targets of Chronic Kidney Disease: Outcomes Quality Initiative (K/DOQI) clinical guidelines as optimal target of serum iPTH, calcium and phosphate. Patients were administered cinacalcet as a single oral daily dose of 30 mg and were followed-up for six months. Cinacalcet treatment for six months resulted in a significant reduction in the serum phosphate and iPTH levels while the serum calcium levels remained unchanged. Thirty-six percent of the patients attained the recommended serum iPTH levels, 40% achieved significant reduction of the serum iPTH levels and 24% showed no favorable response. Only one patient dropped out because of severe gastrointestinal symptoms. Our results suggest that treatment of CKD patients, having moderate to severe secondary hyperparathyroidism, with low-dose cinacalcet is effective and well tolerated.

  2. Constraining Absorption of Organic Aerosol from Biomass Burning with Observations

    Science.gov (United States)

    Feng, Y.; Liu, X.

    2014-12-01

    Biomass burning emissions contribute to a large fraction of global organic aerosol (OA) emissions. In most models, radiative forcing of black carbon (BC) and OA from biomass burning offsets each other to give a small or close to zero total forcing, i.e., an estimate of 0 (-0.2 to +0.2) W m-2 by IPCC-AR5. Recent observational and modeling studies have shown the absorbing part of OA, referred to as "brown" carbon (BrC), to be a significant source of direct absorption of solar radiation thus positive forcing, in particular over regions dominated by biomass burning and biofuel emissions. Here we implement optical treatment for the BrC absorption in the CESM1/CAM5 model, and compare the calculated aerosol spectral absorption with ground-based AERONET and DOE/ARM observations. In this version of CAM5, biomass burning and biofuel OA are treated separately from fossil fuel OA with different imaginary refractive index. Because the absorption of BrC is highly variable and uncertain depending on source, aging, and mixing state, sensitivity studies of BrC refractive index parameterized by fuel type and ratio of BC to OA mass will be examined and the resulting uncertainty in the estimated forcing will be discussed. Preliminary results suggest the simulated wavelength dependence of aerosol absorption, as measured by the absorption Ångström exponent (AAE), increases from 0.9 for non-absorbing OA to 1.2 (or 1.0) for strongly (or moderately) absorbing BrC. The AAE calculated for the strongly absorbing BrC agrees with AERONET spectral observations at 440-870 nm over most regions but overpredicts for the open biomass burning-dominated South America and southern Africa, in which inclusion of moderately absorbing BrC exhibits better agreement.

  3. Erythrocyte fluorescence and lead intoxication.

    Science.gov (United States)

    Clark, K G

    1976-01-01

    Blood samples from people exposed to inorganic lead were examined by fluorescence microscopy for excess erythrocyte porphyrin. With continued lead absorption, fluorescent erythrocytes appeared in the circulation of workers handling this metal or its compounds, and they progressively increased in number and brilliance. These changes ensued if the blood lead concentration was maintained above 2-42 mumol/l (50 mug/100 ml), and preceded any material fall in the haemoglobin value. At one factory, 62-5% of 81 symptomless workers showed erythrocyte fluorescence attributable to the toxic effects of lead. Excess fluorocytes were found in blood samples from a child with pica and three of her eight siblings. These four were subsequently shown to have slightly increased blood lead concentrations (2-03 to 2-32 mumol/l). Fluorescence microscopy for excess erythrocyte porphyrin is a sensitive method for the detection of chronic lead intoxication. A relatively slight increase in the blood lead is associated with demonstrabel changes in erythrocyte porphyrin content. The procedure requires little blood, and may be performed upon stored samples collected for lead estimation. The results are not readily influenced by contamination, and provide good confirmatory evidence for the absorption of biochemically active lead. PMID:963005

  4. A combined matrix isolation spectroscopy and cryosolid positron moderation apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Molek, Christopher D.; Michael Lindsay, C.; Fajardo, Mario E. [Air Force Research Laboratory, Munitions Directorate, Ordnance Division, Energetic Materials Branch, AFRL/RWME, 2306 Perimeter Road, Eglin AFB, Florida 32542-5910 (United States)

    2013-03-15

    We describe the design, construction, and operation of a novel apparatus for investigating efficiency improvements in thin-film cryogenic solid positron moderators. We report results from solid neon, argon, krypton, and xenon positron moderators which illustrate the capabilities and limitations of our apparatus. We integrate a matrix isolation spectroscopy diagnostic within a reflection-geometry positron moderation system. We report the optical thickness, impurity content, and impurity trapping site structures within our moderators determined from infrared absorption spectra. We use a retarding potential analyzer to modulate the flow of slow positrons, and report positron currents vs. retarding potential for the different moderators. We identify vacuum ultraviolet emissions from irradiated Ne moderators as the source of spurious signals in our channel electron multiplier slow positron detection channel. Our design is also unusual in that it employs a sealed radioactive Na-22 positron source which can be translated relative to, and isolated from, the cryogenic moderator deposition substrate. This allows us to separate the influences on moderator efficiency of surface contamination by residual gases from those of accumulated radiation damage.

  5. Spectroscopic study of low-temperature hydrogen absorption in palladium

    Energy Technology Data Exchange (ETDEWEB)

    Ienaga, K., E-mail: ienaga@issp.u-tokyo.ac.jp; Takata, H.; Onishi, Y.; Inagaki, Y.; Kawae, T. [Department of Applied Quantum Physics, Faculty of Engineering, Kyushu University, Motooka, Nishi-Ku, Fukuoka 819-0395 (Japan); Tsujii, H. [Department of Physics, Faculty of Education, Kanazawa University, Kakuma-machi, Kanazawa 920-1192 (Japan); Kimura, T. [Department of Physics, Kyushu University, Hakozaki, Higashi-Ku, Fukuoka 812-8581 (Japan)

    2015-01-12

    We report real-time detection of hydrogen (H) absorption in metallic palladium (Pd) nano-contacts immersed in liquid H{sub 2} using inelastic electron spectroscopy (IES). After introduction of liquid H{sub 2}, the spectra exhibit the time evolution from the pure Pd to the Pd hydride, indicating that H atoms are absorbed in Pd nano-contacts even at the temperature where the thermal process is not expected. The IES time and bias voltage dependences show that H absorption develops by applying bias voltage 30 ∼ 50 mV, which can be explained by quantum tunneling. The results represent that IES is a powerful method to study the kinetics of high density H on solid surface.

  6. Message sidedness in advertising: the moderating roles of need for cognition and time pressure in persuasion.

    Science.gov (United States)

    Kao, Danny Tengti

    2011-08-01

    Persuasion has been extensively researched for decades. Much of this research has focused on different message tactics and their effects on persuasion (e.g., Chang & Chou, 2008; Lafferty, 1999). This research aims to assess whether the persuasion of a specific type of message is influenced by need for cognition (NFC) and time pressure. The 336 undergraduates participated in a 2 (message sidedness: one-sided/two-sided) × 3 (time pressure: low/moderate/high) between-subjects design. Results indicate that two-sided messages tend to elicit more favorable ad attitudes than one-sided messages. As compared with low-NFC individuals, high-NFC individuals are likely to express more favorable ad attitudes, brand attitudes and purchase intention. Moderate time pressure tends to lead to more favorable ad attitudes than low time pressure and high time pressure. In addition, moderate time pressure is likely to elicit more favorable brand attitudes and purchase intentions than high time pressure, but does not elicit more favorable brand attitudes and purchase intentions than low time pressure. Furthermore, when high-NFC individuals are under low or moderate time pressure, two-sided messages are more persuasive than one-sided messages; however, message sidedness does not differentially affect the persuasion when high-NFC individuals are pressed for time. In contrast, one-sided messages are more persuasive than two-sided messages when low-NFC individuals are under low or high time pressure, and two-sided messages are more persuasive than one-sided messages when low-NFC individuals are under moderate time pressure. © 2011 The Author. Scandinavian Journal of Psychology © 2011 The Scandinavian Psychological Associations.

  7. Absorption and Metabolism of Xanthophylls

    Directory of Open Access Journals (Sweden)

    Eiichi Kotake-Nara

    2011-06-01

    Full Text Available Dietary carotenoids, especially xanthophylls, have attracted significant attention because of their characteristic biological activities, including anti-allergic, anti-cancer, and anti-obese actions. Although no less than forty carotenoids are ingested under usual dietary habits, only six carotenoids and their metabolites have been found in human tissues, suggesting selectivity in the intestinal absorption of carotenoids. Recently, facilitated diffusion in addition to simple diffusion has been reported to mediate the intestinal absorption of carotenoids in mammals. The selective absorption of carotenoids may be caused by uptake to the intestinal epithelia by the facilitated diffusion and an unknown excretion to intestinal lumen. It is well known that β-carotene can be metabolized to vitamin A after intestinal absorption of carotenoids, but little is known about the metabolic transformation of non provitamin A xanthophylls. The enzymatic oxidation of the secondary hydroxyl group leading to keto-carotenoids would occur as a common pathway of xanthophyll metabolism in mammals. This paper reviews the absorption and metabolism of xanthophylls by introducing recent advances in this field.

  8. Absorption and metabolism of xanthophylls.

    Science.gov (United States)

    Kotake-Nara, Eiichi; Nagao, Akihiko

    2011-01-01

    Dietary carotenoids, especially xanthophylls, have attracted significant attention because of their characteristic biological activities, including anti-allergic, anti-cancer, and anti-obese actions. Although no less than forty carotenoids are ingested under usual dietary habits, only six carotenoids and their metabolites have been found in human tissues, suggesting selectivity in the intestinal absorption of carotenoids. Recently, facilitated diffusion in addition to simple diffusion has been reported to mediate the intestinal absorption of carotenoids in mammals. The selective absorption of carotenoids may be caused by uptake to the intestinal epithelia by the facilitated diffusion and an unknown excretion to intestinal lumen. It is well known that β-carotene can be metabolized to vitamin A after intestinal absorption of carotenoids, but little is known about the metabolic transformation of non provitamin A xanthophylls. The enzymatic oxidation of the secondary hydroxyl group leading to keto-carotenoids would occur as a common pathway of xanthophyll metabolism in mammals. This paper reviews the absorption and metabolism of xanthophylls by introducing recent advances in this field.

  9. Long Elastic Open Neck Acoustic Resonator for low frequency absorption

    Science.gov (United States)

    Simon, Frank

    2018-05-01

    Passive acoustic liners, used in aeronautic engine nacelles to reduce radiated fan noise, have a quarter-wavelength behavior, because of perforated sheets backed by honeycombs (with one or two degrees of freedom). However, their acoustic absorption ability is naturally limited to medium and high frequencies because of constraints in thickness. The low ratio "plate thickness/hole diameter" generates impedance levels dependent on the incident sound pressure level and the grazing mean flow (by a mechanism of nonlinear dissipation through vortex shedding), which penalises the optimal design of liners. The aim of this paper is to overcome this problem by a concept called LEONAR ("Long Elastic Open Neck Acoustic Resonator"), in which a perforated plate is coupled with tubes of variable lengths inserted in a limited volume of a back cavity. To do this, experimental and theoretical studies, using different types of liners (material nature, hole diameter, tube length, cavity thickness) are described in this paper. It is shown that the impedance can be precisely determined with an analytical approach based on parallel transfer matrices of tubes coupled to the cavity. Moreover, the introduction of tubes in a cavity of a conventional resonator generates a significant shift in the frequency range of absorption towards lower frequencies or allows a reduction of cavity thickness. The impedance is practically independent of sound pressure level because of a high ratio "tube length/tube hole diameter". Finally, a test led in an aeroacoustic bench suggests that a grazing flow at a bulk Mach number of 0.3 has little impact on the impedance value. These first results allow considering these resonators with linear behavior as an alternative to classical resonators, in particular, as needed for future Ultra High Bypass Ratio engines with shorter and thinner nacelles.

  10. In Rwandese Women with Low Iron Status, Iron Absorption from Low-Phytic Acid Beans and Biofortified Beans Is Comparable, but Low-Phytic Acid Beans Cause Adverse Gastrointestinal Symptoms.

    Science.gov (United States)

    Petry, Nicolai; Rohner, Fabian; Gahutu, Jean Bosco; Campion, Bruno; Boy, Erick; Tugirimana, Pierrot L; Zimmerman, Michael Bruce; Zwahlen, Christian; Wirth, James P; Moretti, Diego

    2016-05-01

    Phytic acid (PA) is a major inhibitor of iron bioavailability from beans, and high PA concentrations might limit the positive effect of biofortified beans (BBs) on iron status. Low-phytic acid (lpa) bean varieties could increase iron bioavailability. We set out to test whether lpa beans provide more bioavailable iron than a BB variety when served as part of a composite meal in a bean-consuming population with low iron status. Dietary iron absorption from lpa, iron-biofortified, and control beans (CBs) (regular iron and PA concentrations) was compared in 25 nonpregnant young women with low iron status with the use of a multiple-meal crossover design. Iron absorption was measured with stable iron isotopes. PA concentration in lpa beans was ∼10% of BBs and CBs, and iron concentration in BBs was ∼2- and 1.5-fold compared with CBs and lpa beans, respectively. Fractional iron absorption from lpa beans [8.6% (95% CI: 4.8%, 15.5%)], BBs [7.3% (95% CI: 4.0%, 13.4%)], and CBs [8.0% (95% CI: 4.4%, 14.6%)] did not significantly differ. The total amount of iron absorbed from lpa beans and BBs was 421 μg (95% CI: 234, 756 μg) and 431 μg (95% CI: 237, 786 μg), respectively, and did not significantly differ, but was >50% higher (P beans were hard to cook, and their consumption caused transient adverse digestive side effects in ∼95% of participants. Gel electrophoresis analysis showed phytohemagglutinin L (PHA-L) residues in cooked lpa beans. BBs and lpa beans provided more bioavailable iron than control beans and could reduce dietary iron deficiency. Digestive side effects of lpa beans were likely caused by PHA-L, but it is unclear to what extent the associated digestive problems reduced iron bioavailability. This trial was registered at clinicaltrials.gov as NCT02215278. © 2016 American Society for Nutrition.

  11. Men and Women Exhibit Similar Acute Hypotensive Responses After Low, Moderate, or High-Intensity Plyometric Training.

    Science.gov (United States)

    Ramírez-Campillo, Rodrigo; Abad-Colil, Felipe; Vera, Maritza; Andrade, David C; Caniuqueo, Alexis; Martínez-Salazar, Cristian; Nakamura, Fábio Y; Arazi, Hamid; Cerda-Kohler, Hugo; Izquierdo, Mikel; Alonso-Martínez, Alicia M

    2016-01-01

    The aim of this study was to compare the acute effects of low-, moderate-, high-, and combined-intensity plyometric training on heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), and rate-pressure product (RPP) cardiovascular responses in male and female normotensive subjects. Fifteen (8 women) physically active normotensive subjects participated in this study (age 23.5 ± 2.6 years, body mass index 23.8 ± 2.3 kg · m(-2)). Using a randomized crossover design, trials were conducted with rest intervals of at least 48 hours. Each trial comprised 120 jumps, using boxes of 20, 30, and 40 cm for low, moderate, and high intensity, respectively. For combined intensity, the 3 height boxes were combined. Measurements were taken before and after (i.e., every 10 minutes for a period of 90 minutes) each trial. When data responses of men and women were combined, a mean reduction in SBP, DBP, and RPP was observed after all plyometric intensities. No significant differences were observed pre- or postexercise (at any time point) for HR, SBP, DBP, or RPP when low-, moderate-, high-, or combined-intensity trials were compared. No significant differences were observed between male and female subjects, except for a higher SBP reduction in women (-12%) compared with men (-7%) after high-intensity trial. Although there were minor differences across postexercise time points, collectively, the data demonstrated that all plyometric training intensities can induce an acute postexercise hypotensive effect in young normotensive male and female subjects.

  12. Phytoplankton absorption predicts patterns in primary productivity in Australian coastal shelf waters

    Science.gov (United States)

    Robinson, C. M.; Cherukuru, N.; Hardman-Mountford, N. J.; Everett, J. D.; McLaughlin, M. J.; Davies, K. P.; Van Dongen-Vogels, V.; Ralph, P. J.; Doblin, M. A.

    2017-06-01

    The phytoplankton absorption coefficient (aPHY) has been suggested as a suitable alternate first order predictor of net primary productivity (NPP). We compiled a dataset of surface bio-optical properties and phytoplankton NPP measurements in coastal waters around Australia to examine the utility of an in-situ absorption model to estimate NPP. The magnitude of surface NPP (0.20-19.3 mmol C m-3 d-1) across sites was largely driven by phytoplankton biomass, with higher rates being attributed to the microplankton (>20 μm) size class. The phytoplankton absorption coefficient aPHY for PAR (photosynthetically active radiation; āPHY)) ranged from 0.003 to 0.073 m-1, influenced by changes in phytoplankton community composition, physiology and environmental conditions. The aPHY coefficient also reflected changes in NPP and the absorption model-derived NPP could explain 73% of the variability in measured surface NPP (n = 41; RMSE = 2.49). The absorption model was applied to two contrasting coastal locations to examine NPP dynamics: a high chlorophyll-high variation (HCHV; Port Hacking National Reference Station) and moderate chlorophyll-low variation (MCLV; Yongala National Reference Station) location in eastern Australia using the GIOP-DC satellite aPHY product. Mean daily NPP rates between 2003 and 2015 were higher at the HCHV site (1.71 ± 0.03 mmol C m-3 d-1) with the annual maximum NPP occurring during the austral winter. In contrast, the MCLV site annual NPP peak occurred during the austral wet season and had lower mean daily NPP (1.43 ± 0.03 mmol C m-3 d-1) across the time-series. An absorption-based model to estimate NPP is a promising approach for exploring the spatio-temporal dynamics in phytoplankton NPP around the Australian continental shelf.

  13. A code for the calculation of self-absorption fractions of photons

    International Nuclear Information System (INIS)

    Jaegers, P.; Landsberger, S.

    1988-01-01

    Neutron activation analysis (NAA) is now a well-established technique used by many researchers and commercial companies. It is often wrongly assumed that these NAA methods are matrix independent over a wide variety of samples. Accuracy at the level of a few percent is often difficult to achieve, since components such as timing, pulse pile-up, high dead-time corrections, sample positioning, and chemical separations may severely compromise the results. One area that has received little attention is the calculation of the effect of self-absorption of gamma-rays (including low-energy ones) in samples, particularly those with major components of high-Z values. The analysis of trace components in lead samples is an obvious example, but other high-Z matrices such as various permutations and combinations of zinc, tin, lead, copper, silver, antimony, etc.; ore concentrates; and meteorites are also affected. The authors have developed a simple but effective personal-computer-compatible user-friendly code, however, which can calculate the amount of energy signal that is lost due to the presence of any amount of one or more Z components. The program is based on Dixon's paper of 1951 for the calculation of self-absorption corrections for linear, cylindrical, and spherical sources. To determine the self-absorption fraction of a photon in a source, the FORTRAN computer code SELFABS was written

  14. Apparatus and method for the measurement of neutron moderating or absorbing properties of objects

    International Nuclear Information System (INIS)

    Untermyer, S.I.

    1981-01-01

    An apparatus and method for measuring the neutron moderating or absorbing properties of objects or materials is disclosed in which a fast neutron source cooperates with a neutron absorbing material which reduces the energy of the fast neutrons by inelastic scattering so that they can be readily thermalized by a moderator. A thermal neutron detector is disposed adjacent the material and serves to detect thermal neutrons emitted by a moderator placed to receive and thermalize the reduced energy neutrons. A material whose absorption is to be measured is placed between a moderator and the detector

  15. Resonant Absorption in GaAs-Based Nanowires by Means of Photo-Acoustic Spectroscopy

    Science.gov (United States)

    Petronijevic, E.; Leahu, G.; Belardini, A.; Centini, M.; Li Voti, R.; Hakkarainen, T.; Koivusalo, E.; Guina, M.; Sibilia, C.

    2018-03-01

    Semiconductor nanowires made of high refractive index materials can couple the incoming light to specific waveguide modes that offer resonant absorption enhancement under the bandgap wavelength, essential for light harvesting, lasing and detection applications. Moreover, the non-trivial ellipticity of such modes can offer near field interactions with chiral molecules, governed by near chiral field. These modes are therefore very important to detect. Here, we present the photo-acoustic spectroscopy as a low-cost, reliable, sensitive and scattering-free tool to measure the spectral position and absorption efficiency of these modes. The investigated samples are hexagonal nanowires with GaAs core; the fabrication by means of lithography-free molecular beam epitaxy provides controllable and uniform dimensions that allow for the excitation of the fundamental resonant mode around 800 nm. We show that the modulation frequency increase leads to the discrimination of the resonant mode absorption from the overall absorption of the substrate. As the experimental data are in great agreement with numerical simulations, the design can be optimized and followed by photo-acoustic characterization for a specific application.

  16. Spectrochemical determination of lead in wines

    Directory of Open Access Journals (Sweden)

    DRAGAN MARKOVIC

    2000-06-01

    Full Text Available The determination of lead in wines of different origin was performed by means of atomic emission spectroscopy with argon stabilized DC. U-shaped arc and electrothermal atomic absorption spectrometry. The comparison of the results obtained by the direct and standard addition method has indicated the presence of a depressive effect of the complex organic matrix. The effect is avoided successfully by mineralization, as well as by dissolution of the samples. Thus, a relative simple but precise and sensitive method involving the application of a stabilized arc and photoelectric detection with time integration of the emission signals is recommended for the determination of low concentrations of lead in wines. The complex organic matrix was investigated by recording the IR spectra of different wine fractions.

  17. Effect of the size of experimental channels of the lead slowing-down spectrometer SVZ-100 (Institute for Nuclear Research, Moscow) on the moderation constant

    Energy Technology Data Exchange (ETDEWEB)

    Latysheva, L. N.; Bergman, A. A.; Sobolevsky, N. M., E-mail: sobolevs@inr.ru [Russian Academy of Sciences, Institute for Nuclear Research (Russian Federation); Ilic, R. D. [Vinca Institute of Nuclear Sciences (Serbia)

    2013-04-15

    Lead slowing-down (LSD) spectrometers have a low energy resolution (about 30%), but their luminosity is 10{sup 3} to 10{sup 4} times higher than that of time-of-flight (TOF) spectrometers. A high luminosity of LSD spectrometers makes it possible to use them to measure neutron cross section for samples of mass about several micrograms. These features specify a niche for the application of LSD spectrometers in measuring neutron cross sections for elements hardly available in macroscopic amounts-in particular, for actinides. A mathematical simulation of the parameters of SVZ-100 LSD spectrometer of the Institute for Nuclear Research (INR, Moscow) is performed in the present study on the basis of the MCNPX code. It is found that the moderation constant, which is the main parameter of LSD spectrometers, is highly sensitive to the size and shape of detecting volumes in calculations and, hence, to the real size of experimental channels of the LSD spectrometer.

  18. Effect of the size of experimental channels of the lead slowing-down spectrometer SVZ-100 (Institute for Nuclear Research, Moscow) on the moderation constant

    International Nuclear Information System (INIS)

    Latysheva, L. N.; Bergman, A. A.; Sobolevsky, N. M.; Ilić, R. D.

    2013-01-01

    Lead slowing-down (LSD) spectrometers have a low energy resolution (about 30%), but their luminosity is 10 3 to 10 4 times higher than that of time-of-flight (TOF) spectrometers. A high luminosity of LSD spectrometers makes it possible to use them to measure neutron cross section for samples of mass about several micrograms. These features specify a niche for the application of LSD spectrometers in measuring neutron cross sections for elements hardly available in macroscopic amounts—in particular, for actinides. A mathematical simulation of the parameters of SVZ-100 LSD spectrometer of the Institute for Nuclear Research (INR, Moscow) is performed in the present study on the basis of the MCNPX code. It is found that the moderation constant, which is the main parameter of LSD spectrometers, is highly sensitive to the size and shape of detecting volumes in calculations and, hence, to the real size of experimental channels of the LSD spectrometer.

  19. Feasibility study of a peer-facilitated low intensity cognitive-behavioral intervention for mild to moderate depression and anxiety in older adults.

    Science.gov (United States)

    Seeley, John R; Manitsas, Tara; Gau, Jeff M

    2017-09-01

    The majority of older adults experiencing depression and/or anxiety do not receive adequate treatment due to limited access to evidence-based practices. Low intensity cognitive-behavioral intervention has been established as an evidence-based practice with the potential to increase the reach to older adults. The purpose of the current study is to evaluate the feasibility, acceptability, and potential efficacy of a low intensity, peer-supported, cognitive-behavioral intervention for mild to moderate depression and/or anxiety delivered by a local intergovernmental agency serving older adults. Sixty-two older adults (81% female) between 55 and 96 years of age were randomly assigned to either a peer-facilitated cognitive-behavioral bibliotherapy condition (n = 31) or a wait-list control condition (n = 31). The 10-week feasibility trial data indicated that (1) a majority of the participants were highly engaged in the intervention with an average number of 7.3 peer sessions attended and 2.1 workbooks completed, (2) the participants were quite satisfied with the peer mentoring sessions and moderately satisfied with the workbooks, and (3) there were clinically meaningful reductions in depressive symptoms for those assigned to the treatment condition compared to those that were wait-listed (d = .43), though the effect was non-significant (p = .099) due to the small sample size. The evidence for the impact on reducing anxiety symptoms was more equivocal with a non-significant, small effect size favoring the treatment condition. The pilot study provided preliminary evidence for the feasibility, acceptability, and potential efficacy of the peer-facilitated low intensity cognitive-behavioral therapy intervention approach.

  20. Hopping absorption edge in silicon inversion layers

    International Nuclear Information System (INIS)

    Kostadinov, I.Z.

    1983-09-01

    The low frequency gap observed in the absorption spectrum of silicon inversion layers is related to the AC variable range hopping. The frequency dependence of the absorption coefficient is calculated. (author)

  1. The Concept of Moderation Among Islamic Pious Predecessors

    Directory of Open Access Journals (Sweden)

    Shumsudin Yabi

    2014-12-01

    Full Text Available Islam is religion of simplicity, moderation, just and perfect that leads its followers to the rightful path. Moderation is an important aspect in our daily life. Prophet Muhammad praise be upon him (PBUH moderate lifestyle is a perfect exemplary. These exemplary has been adapted by previous Islamic scholars in their daily life thus they had emphasized the importance of understanding Al-Quran and Sunnah based on the understanding of previous pious predecessors. Some of the factors that had caused the digression are the diversion, misunderstanding and misinterpretation resulting to improper understanding of the concept on moderation. All these had caused misunderstanding and conflict of interests among us that had caused a disaster to the community. Results of the study found that the pious predecessors had drawn the concepts of moderations in five aspects of life. They are moderation in doing justice and goodness, doing pious deeds, in managing the economic and financial, in following the rightful path and finally moderation in leading our daily life following the exemplary of Prophet Muhammad PBUH.

  2. Lead preconcentration in synthetic samples with triton x-114 in the cloud point extraction and analysis by atomic absorption (EAAF)

    International Nuclear Information System (INIS)

    Zegarra Pisconti, Marixa; Cjuno Huanca, Jesus

    2015-01-01

    A methodology was developed about lead preconcentration in water samples that were added dithizone as complexing agent, previously dissolved in the nonionic surfactant Triton X-114, until the formation of the critical micelle concentration and the cloud point temperature. The centrifuged system gave a precipitate with high concentrations of Pb (II) that was measured by atomic absorption spectroscopy with flame (EAAF). The method has proved feasible to be implemented as a method of preconcentration and analysis of Pb in aqueous samples with concentrations less than 1 ppm. Several parameters were evaluated to obtain a percentage recovery of 89.8%. (author)

  3. Influence of food matrix on absorption of flavour compounds by linear low-density polyethylene: proteins and carbohydrates

    NARCIS (Netherlands)

    Willige, van R.W.G.; Linssen, J.P.H.; Voragen, A.G.J.

    2000-01-01

    The influence of oil and food components in real food products on the absorption of four flavour compounds (limonene, decanal, linalool and ethyl 2-methyl butyrate) into linear low-density polyethylene (LLDPE) was studied using a large volume injection GC in vial extraction method. Model food

  4. Inhibition of two-photon absorption in a three-level system with a pair of bichromatic fields

    International Nuclear Information System (INIS)

    Zou Jinhua; Hu Xiangming; Cheng Guangling; Li Xing; Du Dan

    2005-01-01

    We study two-photon absorption in a three-level ladder atomic system driven by a pair of bichromatic fields of equal frequency differences. The high-frequency component of one bichromatic field and the low-frequency component of the other are on two-photon resonance. The transition probability is calculated by employing the method of harmonic expansion and matrix inversion. Unexpectedly, when the sums of the phases of the different pairs of field components on the two-photon resonance are equal to each other, two-photon absorption is dramatically suppressed and the atomic system becomes transparent against two-photon absorption. Physically, due to dynamical Stark splitting, the two-photon transitions induced by the different pairs of field components experience different dressed states with phase difference of π. As a result, destructive interference occurs between the two pathways and leads to the inhibition of two-photon absorption

  5. Variable Emittance Electrochromics Using Ionic Electrolytes and Low Solar Absorptance Coatings

    Science.gov (United States)

    Chandrasekhar, Prasanna

    2011-01-01

    One of the last remaining technical hurdles with variable emittance devices or skins based on conducting polymer electrochromics is the high solar absorptance of their top surfaces. This high solar absorptance causes overheating of the skin when facing the Sun in space. Existing technologies such as mechanical louvers or loop heat pipes are virtually inapplicable to micro (solar absorption to Alpha(s) of between 0.30 and 0.46. Coupled with the emittance properties of the variable emittance skins, this lowers the surface temperature of the skins facing the Sun to between 30 and 60 C, which is much lower than previous results of 100 C, and is well within acceptable satellite operations ranges. The performance of this technology is better than that of current new technologies such as microelectromechanical systems (MEMS), electrostatics, and electrophoretics, especially in applications involving micro and nano spacecraft. The coatings are deposited inside a high vacuum, layering multiple coatings onto the top surfaces of variable emittance skins. They are completely transparent in the entire relevant infrared region (about 2 to 45 microns), but highly reflective in the visible-NIR (near infrared) region of relevance to solar absorptance.

  6. Effectiveness of a Low-Calorie Weight Loss Program in Moderately and Severely Obese Patients

    Directory of Open Access Journals (Sweden)

    Julia K. Winkler

    2013-10-01

    Full Text Available Aims: To compare effectiveness of a 1-year weight loss program in moderately and severely obese patients. Methods: The study sample included 311 obese patients participating in a weight loss program, which comprised a 12-week weight reduction phase (low-calorie formula diet and a 40-week weight maintenance phase. Body weight and glucose and lipid values were determined at the beginning of the program as well as after the weight reduction and the weight maintenance phase. Participants were analyzed according to their BMI class at baseline (30-34.9 kg/m2; 35-39.9 kg/m2; 40-44.9 kg/m2; 45-49.9 kg/m2; ≥50 kg/m2. Furthermore, moderately obese patients (BMI 2 were compared to severely obese participants (BMI ≥ 40 kg/m2. Results: Out of 311 participants, 217 individuals completed the program. Their mean baseline BMI was 41.8 ± 0.5 kg/m2. Average weight loss was 17.9 ± 0.6%, resulting in a BMI of 34.3 ± 0.4 kg/m2 after 1 year (p Conclusion: 1-year weight loss intervention improves body weight as well as lipid and glucose metabolism not only in moderately, but also in severely obese individuals.

  7. Surface extended x-ray absorption fine structure of low-Z absorbates using fluorescence detection

    International Nuclear Information System (INIS)

    Stoehr, J.; Kollin, E.B.; Fischer, D.A.; Hastings, J.B.; Zaera, F.; Sette, F.

    1985-05-01

    Comparison of x-ray fluorescence yield (FY) and electron yield surface extended x-ray absorption fine structure spectra above the S K-edge for c(2 x 2) S on Ni(100) reveals an order of magnitude higher sensitivity of the FY technique. Using FY detection, thiophene (C 4 H 4 S) chemisorption on Ni(100) is studied with S coverages down to 0.08 monolayer. The molecule dissociates at temperatures as low as 100K by interaction with fourfold hollow Ni sites. Blocking of these sites by oxygen leaves the molecule intact

  8. Screening Technique for Lead and Cadmium in Toys and Other Materials Using Atomic Absorption Spectroscopy

    Science.gov (United States)

    Brouwer, Henry

    2005-01-01

    A simple procedure to quickly screen different consumer products for the presence of lead, cadmium, and other metals is described. This screening technique avoids expending a lot of preparation time on samples known to contain low levels of hazardous metals where only samples testing positive for the desired elements need to be analyzed…

  9. [Study on Content Determination of Lead and Arsenic in Four Traditional Tibetan Medicine Prescription Preparations by Wet Digestion Flow Injection-Hydride Generation-Atomic Absorption Spectrometry].

    Science.gov (United States)

    Zheng, Zhi-yuan; Du, Yu-zhi; Zhang, Ming; Yu, Ming-jie; Li, Cen; Yang, Hong-xia; Zhao, Jing; Xia, Zheng-hua; Wei, Li-xin

    2015-04-01

    Four common traditional tibetan medicine prescription preparations "Anzhijinghuasan, Dangzuo, Renqingchangjue and Rannasangpei" in tibetan areas were selected as study objects in the present study. The purpose was to try to establish a kind of wet digestion and flow injection-hydride generation-atomic absorption spectrometry (FI-HAAS) associated analysis method for the content determinations of lead and arsenic in traditional tibetan medicine under optimized digestion and measurement conditions and determine their contents accurately. Under these optimum operating conditions, experimental results were as follows. The detection limits for lead and arsenic were 0.067 and 0.012 µg · mL(-1) respectively. The quantification limits for lead and arsenic were 0.22 and 0.041 µg · mL(-1) respectively. The linear ranges for lead and arsenic were 25-1,600 ng · mL(-1) (r = 0.9995) and 12.5-800 ng · mL(-1) (r = 0.9994) respectively. The degrees of precision(RSD) for lead and arsenic were 2.0% and 3.2% respectively. The recovery rates for lead and arsenic were 98.00%-99.98% and 96.67%-99.87% respectively. The content determination results of lead and arsenic in four traditional tibetan medicine prescription preparations were as fol- lows. The contents of lead and arsenic in Anzhijinghuasan are 0.63-0.67 µg · g(-1) and 0.32-0.33 µg · g(-1) in Anzhijinghua- san, 42.92-43.36 µg · g(-1) and 24.67-25.87 µg · g(-1) in Dangzuo, 1,611. 39-1,631.36 µg · g(-1) and 926.76-956.52 µg- g(-1) in Renqing Changjue, and 1,102.28-1,119.127 µg-g(-1) and 509.96-516.87 µg · g(-1) in Rannasangpei, respectively. This study established a method for content determination of lead and arsenic in traditional tibetan medicine, and determined the content levels of lead and arsenic in four tibetan medicine-prescription preparations accurately. In addition, these results also provide the basis for the safe and effective use of those medicines in clinic.

  10. Outflow and hot dust emission in broad absorption line quasars

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Shaohua; Zhou, Hongyan [Polar Research Institute of China, 451 Jinqiao Road, Shanghai 200136 (China); Wang, Huiyuan; Wang, Tinggui; Xing, Feijun; Jiang, Peng [Key Laboratory for Research in Galaxies and Cosmology, University of Science and Technology of China, Chinese Academy of Sciences, Hefei, Anhui 230026 (China); Zhang, Kai, E-mail: zhangshaohua@pric.gov.cn, E-mail: whywang@mail.ustc.edu.cn [Key Laboratory for Research in Galaxies and Cosmology, Shanghai Astronomical Observatory, Chinese Academy of Sciences, 80 Nandan Road, Shanghai 200030 (China)

    2014-05-01

    We have investigated a sample of 2099 broad absorption line (BAL) quasars with z = 1.7-2.2 built from the Sloan Digital Sky Survey Data Release Seven and the Wide-field Infrared Survey. This sample is collected from two BAL quasar samples in the literature and is refined by our new algorithm. Correlations of outflow velocity and strength with a hot dust indicator (β{sub NIR}) and other quasar physical parameters—such as an Eddington ratio, luminosity, and a UV continuum slope—are explored in order to figure out which parameters drive outflows. Here β{sub NIR} is the near-infrared continuum slope, which is a good indicator of the amount of hot dust emission relative to the accretion disk emission. We confirm previous findings that outflow properties moderately or weakly depend on the Eddington ratio, UV slope, and luminosity. For the first time, we report moderate and significant correlations of outflow strength and velocity with β{sub NIR} in BAL quasars. It is consistent with the behavior of blueshifted broad emission lines in non-BAL quasars. The statistical analysis and composite spectra study both reveal that outflow strength and velocity are more strongly correlated with β{sub NIR} than the Eddington ratio, luminosity, and UV slope. In particular, the composites show that the entire C IV absorption profile shifts blueward and broadens as β{sub NIR} increases, while the Eddington ratio and UV slope only affect the high and low velocity part of outflows, respectively. We discuss several potential processes and suggest that the dusty outflow scenario, i.e., that dust is intrinsic to outflows and may contribute to the outflow acceleration, is most likely.

  11. Modelling LiBr-H2O solution concentration/crystallization of low thermal-powered absorption air conditioning system

    International Nuclear Information System (INIS)

    Abdullah, M.O.

    2000-01-01

    A computer model is developed to predict the concentration of lithium bromide - water (LiBr-H 2 O) solution for used in low thermal energy-driven absorption air conditioning plants design. The computer program is capable to alert the users from undesirable solidification or crystallization zones. Good agreements between simulated concentration and experimental data from standard chart/table have been obtained. (Author)

  12. Developmental immunotoxicology of lead

    International Nuclear Information System (INIS)

    Dietert, Rodney R.; Lee, Ji-Eun; Hussain, Irshad; Piepenbrink, Michael

    2004-01-01

    The heavy metal, lead, is a known developmental immunotoxicant that has been shown to produce immune alterations in humans as well as other species. Unlike many compounds that exert adverse immune effects, lead exposure at low to moderate levels does not produce widespread loss of immune cells. In contrast, changes resulting from lead exposure are subtle at the immune cell population level but, nevertheless, can be functionally dramatic. A hallmark of lead-induced immunotoxicity is a pronounced shift in the balance in T helper cell function toward T helper 2 responses at the expense of T helper 1 functions. This bias alters the nature and range of immune responses that can be produced thereby influencing host susceptibility to various diseases. Immunotoxic responses to lead appear to differ across life stages not only quantitatively with regard to dose response, but also qualitatively in terms of the spectrum of immune alterations. Experimental studies in several lab animal species suggest the latter stages of gestation are a period of considerable sensitivity for lead-induced immunotoxicity. This review describes the basic characteristics of lead-induced immunotoxicity emphasizing experimental animal results. It also provides a framework for the consideration of toxicant exposure effects across life stages. The existence of and probable basis for developmental windows of immune hyper-susceptibility are presented. Finally, the potential for lead to serve as a perinatal risk factor for childhood asthma as well as other diseases is considered

  13. [Studies on markers of exposure and early effect in areas with arsenic pollution: methods and results of the project SEpiAs. Epidemiological studies on population exposed to low-to-moderate arsenic concentration in drinking water].

    Science.gov (United States)

    Bustaffa, Elisa; Bianchi, Fabrizio

    2014-01-01

    Arsenic and its inorganic compounds are classified as human carcinogens. Several epidemiological studies conducted in areas of the world characterized by high arsenic concentration in drinking water, even up to 3,000 μg/l, report associations between arsenic exposure and skin, bladder, lung, liver and kidney cancer as well as cardiovascular diseases, diabetes and reproductive and developmental effects. Since general population is not exposed to these high arsenic concentrations in the last years attention focused on adverse health effects that low-to-moderate arsenic concentrations (0-150 μg/l) in drinking water could induce. The World Health Organization recommends a maximum limit of 10 μg/l for arsenic in drinking water. Almost all epidemiological studies conducted on populations exposed to low-to-moderate arsenic concentrations in drinking water are limited due to problems arising from both individual exposure assessment and low subjects number. The aim of the present review is to collect literature-based evidences regarding adverse health effects associated with exposure to low-to-moderate arsenic concentrations in drinking water (10-150 μg/l) in order to obtain a comprehensive picture of the health outcomes that such exposure can have on general population.

  14. Low blood lead levels impair intellectual and hematological function in children from Cartagena, Caribbean coast of Colombia.

    Science.gov (United States)

    Alvarez-Ortega, Neda; Caballero-Gallardo, Karina; Olivero-Verbel, Jesus

    2017-12-01

    Lead produces numerous biochemical and physiological changes in humans, including hematological disorders, toxic effects on the central nervous system and in the function of several organs. The aim of this study was to determine blood lead levels (BLL) in children from Cartagena, Colombia, associating those with hematological and liver damage markers, the intelligence quotient (IQ), as well as with gene expression of the aminolevulinate dehydratase (ALAD), superoxide dismutase 1 (SOD1), gamma interferon (INF-γ), tumor necrosis factor (TNF) and tumor protein (p53). To achieve this purpose, 118 blood samples were collected from children 5-16 years old, with their respective informed consent from their parents. BLL was measured by atomic absorption; hematological parameters were obtained with automated systems; plasma was utilized to analyze hepatic toxicity markers, alanine aminotransferase (ALT), gamma-glutamyltransferase (γ-GT) and alkaline phosphatase (ALP); the Kaufman Brief Intelligence Test (K-BIT) was administered to measure the IQ; and gene expression was quantified from blood RNA. The mean BLL was 1.7±0.3μg/dL. A low proportion of the children (3.4%) had BLL above the CDC recommended limit (5μg/dL). BLL were correlated weakly, but negatively with child age, weight, height, body mass index, platelets wide distribution, mean platelet volume, γ-GT and IQ. There were not significant changes in the expression of evaluated genes. These results support the hypothesis that BLL below 5μg/dL may still be a detrimental factor on children's cognitive abilities, development and hematology, in line with recent concerns that there is no safe level of pediatric lead exposure. Copyright © 2017 Elsevier GmbH. All rights reserved.

  15. Solid phase extraction of lead on octadecyl bonded silica membrane disk modified with Cyanex302 and determination by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Karve, Manjusha; Rajgor, Reeta V.

    2007-01-01

    A simple, reliable and rapid method for preconcentration and determination of lead using octadecyl bonded silica membrane disk impregnated with Cyanex302 and flame atomic absorption spectrometry is presented. The influence of aqueous phase pH, type of eluent, flow rates of sample solution and eluent, volume of eluent and amount of extractant has been investigated. The break through volume is greater than 4.0 dm 3 with an enrichment factor of more than 400 and a detection limit of 1.0 μg dm -3 . The method developed for determination of lead is good as six replicate determinations using 100 cm 3 solution containing lead in the range 1-4900 μg provides a relative standard deviation (R.S.D.) of 0.4%. The selectivity of the proposed method was confirmed from the interference studies. The developed procedure was successfully applied for the determination of lead in spiked sea water, USGS standard soil sample, sludge and industrial effluents, medicinal formulation, plant, some food products and wine

  16. A novel application of reactive absorption to break the CO2–ethane azeotrope with low energy requirement

    International Nuclear Information System (INIS)

    Tavan, Yadollah; Hosseini, Seyyed Hossein

    2013-01-01

    Highlights: • Investigation of RA for the CO 2 –ethane azeotropic process using Hysys simulator. • Optimization of operating parameters to minimize energy demand in the proposed RA process. • Superior performance of the RA process compared to the conventional process. • Enhance in NGL production from 795 to 1120 mole/s compared to the conventional process. - Abstract: Azeotropic separation of ethane and CO 2 using reactive absorption (RA) is studied by Hysys process software. A new configuration of a RA process is proposed using diethanolamine (DEA) to break the azeotrope. Impacts of amine flow rate, amine inlet temperature and feed–inlet location are investigated to achieve an optimum condition of the process in terms of energy demand. The simulation results show that optimum values of amine flow rate, amine temperature and feed–inlet location are 1900 mole/s, 30 °C and 20th stage, respectively. It is found that the process including RA leads to a significant reduction in operating costs, compared to the conventional extractive process

  17. Thermodynamic performance optimization of the absorption-generation process in an absorption refrigeration cycle

    International Nuclear Information System (INIS)

    Chen, Yi; Han, Wei; Jin, Hongguang

    2016-01-01

    Highlights: • This paper proposes a new thermal compressor model with boost pressure ratio. • The proposed model is an effective way to optimize the absorption-generation process. • Boost pressure ratio is a key parameter in the proposed thermal compressor model. • The optimum boost pressure ratios for two typical refrigeration systems are obtained. - Abstract: The absorption refrigeration cycle is a basic cycle that establishes the systems for utilizing mid-low temperature heat sources. A new thermal compressor model with a key parameter of boost pressure ratio is proposed to optimize the absorption-generation process. The ultimate generation pressure and boost pressure ratio are used to represent the potential and operating conditions of the thermal compressor, respectively. Using the proposed thermal compressor model, the operation mechanism and requirements of the absorption refrigeration system and absorption-compression refrigeration system are elucidated. Furthermore, the two typical heat conversion systems are optimized based on the thermal compressor model. The optimum boost pressure ratios of the absorption refrigeration system and the absorption-compression refrigeration system are 0.5 and 0.75, respectively. For the absorption refrigeration system, the optimum generation temperature is 125.31 °C at the cooling water temperature of 30 °C, which is obtained by simple thermodynamic calculation. The optimized thermodynamic performance of the absorption-compression refrigeration system is 16.7% higher than that of the conventional absorption refrigeration system when the generation temperature is 100 °C. The thermal compressor model proposed in this paper is an effective method for simplifying the optimization of the thermodynamic systems involving an absorption-generation process.

  18. Skin toxicology of lead species evaluated by their permeability and proteomic profiles: a comparison of organic and inorganic lead.

    Science.gov (United States)

    Pan, Tai-Long; Wang, Pei-Wen; Al-Suwayeh, Saleh A; Chen, Chih-Chieh; Fang, Jia-You

    2010-08-01

    Lead compounds are known to cause cytotoxicity and genotoxicity. Lead absorption by the skin is an important route through which this metal enters the body. The purpose of this work was to evaluate the skin permeability and toxicological profiles of two lead species, lead acetate and lead nitrate. This study assessed lead-induced toxicity mechanisms by focusing on the histopathology, proteomics, cell growth, and cellular ATP. In vitro skin permeation assays showed that there was no significant difference of lead accumulation within and across the skin between the two lead species. The presence of simulated sweat reduced the skin uptake of lead. The skin deposition of lead acetate was greater than that of lead nitrate with in vivo topical application. On the other hand, lead nitrate produced greater changes in the skin's histology and proteomic profiles compared to lead acetate. Four protein spots which showed significant changes were identified and are discussed in this study. These included glucose-related protein precursor (GRP) 78, K14, alpha-actin, and Rho GDP-dissociation inhibitor 2 (RhoGDI2). These proteins are respectively associated with oxidative stress, apoptosis, wound healing, and proliferation. Lead presented a biphasic pattern on cell growth and intracellular ATP content, with a stimulating effect at low concentrations and an inhibitory effect on cell proliferation at higher concentrations. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  19. Postoperative Corneal Asphericity in Low, Moderate, and High Myopic Eyes After Transepithelial PRK Using a New Pulse Allocation.

    Science.gov (United States)

    Lin, David T C; Holland, Simon P; Verma, Shwetabh; Hogden, John; Arba-Mosquera, Samuel

    2017-12-01

    To evaluate the postoperative asphericity in low, moderate, and high myopic eyes after combined transepithelial photorefractive keratectomy and SmartSurf ACE treatment (SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany). In this retrospective case series, the outcomes of myopic SmartSurf ACE were evaluated at 3 months postoperatively in 106 eyes and divided into low (less than -4.125 diopters [D]), moderate (-4.125 to -6.25 D), and high (more than -6.25 D) myopia groups. In all cases, standard examinations and preoperative and postoperative corneal topography (SCHWIND Sirius) were performed. The analysis comprised evaluating the change in asphericity versus planned correction, comparing expected and achieved postoperative asphericity for all eyes, and comparison of the three groups in terms of the preoperative and postoperatively expected and achieved asphericity. RESULTS At 3 months postoperatively, the low myopia group (n = 33) improved average negative asphericity (Q = -0.04 ± 0.17 preoperative vs -0.19 ± 0.20 postoperative, P .10), but showed significant differences postoperatively (P < .007). The cohort's average preoperative corrected distance visual acuity was 0.01 ± 0.04 logMAR (range: 0.0 to 0.18 logMAR) and uncorrected distance visual acuity was 0.03 ± 0.08 logMAR (range: -0.12 to 0.40 logMAR) 3 months postoperatively. SmartSurf ACE maintained or slightly improved preoperative corneal asphericity for low to moderate myopic corrections (up to -6.00 D). This may provide advantages in the quality of vision and the onset of presbyopic symptoms after laser refractive surgery in myopic patients. [J Refract Surg. 2017;33(12):820-826.]. Copyright 2017, SLACK Incorporated.

  20. Metabolism of lead-210 in juvenile and adult rhesus monkeys (Macaca mulatta)

    International Nuclear Information System (INIS)

    Pounds, J.G.; Marlar, R.J.; Allen, J.R.

    1978-01-01

    Experiments were conducted measuring the gastrointestinal absorption and elimination of a single dose of lead-210 acetate in infant and adult rhesus monkeys. Urinary and fecal excretion of absorbed lead was followed for 23 days. Infant monkeys eliminated less and absorbed more orally administered lead. Adult animals excreted more absorbed lead in feces, while urinary excretion between adults and infants was similar. Increased absorption of administered lead and reduced fecal excretion of absorbed lead resulted in significantly greater body burden of lead-210 in infant animals. Blood lead values were increased in the infant animals, and were inversely correlated with body burden and percent absorption of ingested lead

  1. Slowing down with resonance absorption

    International Nuclear Information System (INIS)

    Moura Neto, C. de; Nair, R.P.K.

    1979-08-01

    The presence of heavy nuclei in nuclear reactors, in significant concentrations, facilitates the appearance of absorption resonances. For the moderation in the presence of absorbers an exact solution of the integral equations is possible by numerical methods. Approximated solutions for separated resonances in function of the practical width, (NR and NRIM approximations) are discussed in this paper. The method is generalized, presenting the solution by an intermediate approximation, in the definition of the resonance integral. (Author) [pt

  2. Free and protein-bound cobalamin absorption in healthy middle-aged and older subjects.

    Science.gov (United States)

    van Asselt, D Z; van den Broek, W J; Lamers, C B; Corstens, F H; Hoefnagels, W H

    1996-08-01

    and egg yolk 57 Co-cobalamin excretions were not reduced in the atrophic gastritis group when compared with the non-atrophic gastritis group. Median plasma cobalamin concentration was not significantly lower in older subjects (P = .205). Nonetheless, plasma cobalamin concentration correlated negatively with age (r = -.36; P = .008). We demonstrated no significant difference in either free or protein-bound cobalamin absorption between healthy middle-aged and older adults. In addition, no alteration in cobalamin absorption was found in subjects identified as having mild to moderate atrophic gastritis. Therefore, based on our results, the high prevalence of low cobalamin levels in older people cannot be explained by either the aging process or mild to moderate atrophic gastritis.

  3. H2O temperature sensor for low-pressure flames using tunable diode laser absorption near 2.9 νm

    KAUST Repository

    Li, Sijie; Farooq, Aamir; Hanson, Ronald Kenneth

    2011-01-01

    Making use of a newly available rapid-tuning diode laser operating at wavelengths up to 2.9 νm, an absorption-based temperature sensor was developed for in situ measurements in low-pressure flames. Based on the systematic analysis of H2O vapor

  4. Blood lead levels in preschool children in Cape Town

    Energy Technology Data Exchange (ETDEWEB)

    Deveaux, P.; Kibel, M.A.; Dempster, W.S.; Pocock, F.; Formenti, K.

    1986-03-29

    Blood lead levels were assessed in 293 children aged between 4 and 6 years attending preschool centers in metropolitan Cape Town in order to establish the degree of lead absorption. Anthropometric data, blood count, zinc protoporphyrin and blood lead level were obtained for each child. A questionnaire was used to determine socio-economic status, dietary habits and history of pica. Thirteen children, or 4,4% of those sampled, had blood levels of greater than or equal to 30 micrograms/dl. The majority of these children lived in close proximity to one another in a socially deprived inner urban environment. Environmental sampling for lead was carried out in the homes of children with the highest blood levels as well as in the homes of a matched control group with low levels living in the same area. The only difference was a significantly higher incidence of pica in the children with high levels.

  5. Dietary exposure to cadmium, lead and nickel among students from south-east Poland.

    Science.gov (United States)

    Marzec, Zbigniew; Koch, Wojciech; Marzec, Agnieszka; Żukiewicz-Sobczak, Wioletta

    2014-01-01

    The dietary intake of cadmium, lead and nickel was determined among students from three universities in the city of Lublin in south-east Poland to assess the levels of exposure to these contaminants, compared to PTWI and TDI values. The study was performed in 2006–2010 and involved 850 daily food rations of students. The technique of 24-hour dietary recall and diet duplicates was used. Cadmium, lead and nickel complexes with ammonium-pyrrolidindithiocarbamate were formed and extracted to the organic phase with 4-methylpentan-2-one–MIBK, in which their content was measured by flame atomic absorption spectrometry. The highest intake of the elements studied was observed in 2008. The data show that in none of the cases, the level of intake reached 70% of PTWI/TDI values, and thus the risk of developing diseases related to high exposure to these toxic metals absorbed from foodstuffs was low. The parameters of methods were checked during determinations by adding standard solutions to the samples before mineralization and by using two reference materials: Total diet ARC/CL HDP and Bovine muscle RM NIST 8414. The dietary exposure to lead and cadmium has significantly decreased in recent years, whereas the exposures to nickel remains on a stable level.

  6. Searching out the hydrogen absorption/desorption limiting reaction factors: Strategies allowing to increase kinetics

    Energy Technology Data Exchange (ETDEWEB)

    Zeaiter, Ali, E-mail: ali.zeaiter@femto-st.fr; Chapelle, David; Nardin, Philippe

    2015-10-05

    Highlights: • A macro scale thermodynamic model that simulates the response of a FeTi-X hydride tank is performed, and validated experimentally. • A sensibility study to identify the most influent input variables that can changes very largely the reaction rate. - Abstract: Hydrogen gas has become one of the most promising energy carriers. Main breakthrough concerns hydrogen solid storage, specially based on intermetallic material use. Regarding the raw material abundance and cost, the AB type alloy FeTi is an auspicious candidate to store hydrogen. Its absorption/desorption kinetics is a basic hindrance to common use, compared with more usual hydrides. First, discussions based on literature help us identifying the successive steps leading to metal hydriding, and allow to introduce the physical parameters which drive or limit the reaction. This analysis leads us to suggest strategies in order to increase absorption/desorption kinetics. Attention is then paid to a thermofluidodynamic model, allowing to describe a macroscopic solid storage reactor. Thus, we can achieve a simulation which describes the overall reaction inside the hydrogen reactor and, by varying the sub-mentioned parameters (thermal conductivity, the powder granularity, environment heat exchange…), we attempt to hierarchy the reaction limiting factors. These simulations are correlated to absorption/desorption experiments for which pressure, temperature and hydrogen flow are recorded.

  7. Cadmium and lead determination in foods by beam injection flame furnace atomic absorption spectrometry after ultrasound-assisted sample preparation

    International Nuclear Information System (INIS)

    Aleixo, Poliana Carolina; Junior, Dario Santos; Tomazelli, Andrea Cristina; Rufini, Iolanda A.; Berndt, Harald; Krug, Francisco Jose

    2004-01-01

    A simple method for cadmium and lead determination in foods by beam injection flame furnace atomic absorption spectrometry (BIFF-AAS) was proposed. Food slurries were prepared by transferring an exact amount of cryogenic-ground homogenized material (50-100 mg) to centrifuge tubes, followed by addition of 5 ml (up to 2.8 mol l -1 ) nitric acid solution and sonication in an ultrasonic bath during 5-10 min. Thereafter, slurries were diluted with water to 10 ml, centrifuged during 5 min at 5400 rpm and 400 μl aliquot of the supernatant was analyzed by BIFF-AAS. The detection limits based on peak height measurements were 0.03 μg g -1 Cd and 1.6 μg g -1 Pb for 2% (m/v) slurry (200 mg/10 ml). For method validation, the certified reference materials Pig Kidney (BCR 186) and Rice Flour (NIES 10) were used. Quantitative cadmium and lead recoveries were obtained and no statistical differences were found at 95% level by applying the t-test

  8. Agnostic stacking of intergalactic doublet absorption: measuring the Ne VIII population

    Science.gov (United States)

    Frank, Stephan; Pieri, Matthew M.; Mathur, Smita; Danforth, Charles W.; Shull, J. Michael

    2018-05-01

    We present a blind search for doublet intergalactic metal absorption with a method dubbed `agnostic stacking'. Using a forward-modelling framework, we combine this with direct detections in the literature to measure the overall metal population. We apply this novel approach to the search for Ne VIII absorption in a set of 26 high-quality COS spectra. We probe to an unprecedented low limit of log N>12.3 at 0.47≤z ≤1.34 over a path-length Δz = 7.36. This method selects apparent absorption without requiring knowledge of its source. Stacking this mixed population dilutes doublet features in composite spectra in a deterministic manner, allowing us to measure the proportion corresponding to Ne VIII absorption. We stack potential Ne VIII absorption in two regimes: absorption too weak to be significant in direct line studies (12.3 13.7). We do not detect Ne VIII absorption in either regime. Combining our measurements with direct detections, we find that the Ne VIII population is reproduced with a power-law column density distribution function with slope β = -1.86 ^{+0.18 }_{ -0.26} and normalization log f_{13.7} = -13.99 ^{+0.20 }_{ -0.23}, leading to an incidence rate of strong Ne VIII absorbers dn/dz =1.38 ^{+0.97 }_{ -0.82}. We infer a cosmic mass density for Ne VIII gas with 12.3 value significantly lower that than predicted by recent simulations. We translate this density into an estimate of the baryon density Ωb ≈ 1.8 × 10-3, constituting 4 per cent of the total baryonic mass.

  9. A l% and 1cm Perspective Leads to a Novel CDOM Absorption Algorithm

    Science.gov (United States)

    Morrow, J. H.; Hooker, S. B.; Matsuoka, A.

    2012-01-01

    A next-generation in-water profiler designed to measure the apparent optical properties of seawater was developed and validated across a wide dynamic range of water properties. This new Compact-Optical Profiling System (C-OPS) design uses a novel, kite-shaped, free-falling backplane with adjustable buoyancy and is based on 19 state-of-the-art microradiometers, spanning 320-780 nm. Data collected as part of the field commissioning were of a previously unachievable quality and showed that systematic uncertainties in the sampling protocols were discernible at the 1% optical and 1cm depth resolution levels. A sensitivity analysis as a function of three water types, established by the peak in the remote sensing reflectance spectra, revealed which water types and spectral domains were the most indicative of data acquisition uncertainties. The unprecedented vertical resolution of C-OPS measurements provided near-surface data products at the spectral endpoints with a quality level that has not been obtainable. The improved data allowed development of an algorithm for predicting the spectral absorption due to chromophoric dissolved organic matter (CDOM) using ratios of diffuse attenuation coefficients with over 99% of the variance in the data explained.

  10. Applicability of cloud point extraction for the separation trace amount of lead ion in environmental and biological samples prior to determination by flame atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Sayed Zia Mohammadi

    2016-09-01

    Full Text Available A sensitive cloud point extraction procedure(CPE for the preconcentration of trace lead prior to its determination by flame atomic absorption spectrometry (FAAS has been developed. The CPE method is based on the complex of Pb(II ion with 1-(2-pyridylazo-2-naphthol (PAN, and then entrapped in the non-ionic surfactant Triton X-114. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of PAN and Triton X-114, equilibration temperature and time, were investigated in detail. A preconcentration factor of 30 was obtained for the preconcentration of Pb(II ion with 15.0 mL solution. Under the optimal conditions, the calibration curve was linear in the range of 7.5 ng mL−1–3.5 μg mL−1 of lead with R2 = 0.9998 (n = 10. Detection limit based on three times the standard deviation of the blank (3Sb was 5.27 ng mL−1. Eight replicate determinations of 1.0 μg mL−1 lead gave a mean absorbance of 0.275 with a relative standard deviation of 1.6%. The high efficiency of cloud point extraction to carry out the determination of analytes in complex matrices was demonstrated. The proposed method has been applied for determination of trace amounts of lead in biological and water samples with satisfactory results.

  11. Femtosecond all-optical parallel logic gates based on tunable saturable to reverse saturable absorption in graphene-oxide thin films

    International Nuclear Information System (INIS)

    Roy, Sukhdev; Yadav, Chandresh

    2013-01-01

    A detailed theoretical analysis of ultrafast transition from saturable absorption (SA) to reverse saturable absorption (RSA) has been presented in graphene-oxide thin films with femtosecond laser pulses at 800 nm. Increase in pulse intensity leads to switching from SA to RSA with increased contrast due to two-photon absorption induced excited-state absorption. Theoretical results are in good agreement with reported experimental results. Interestingly, it is also shown that increase in concentration results in RSA to SA transition. The switching has been optimized to design parallel all-optical femtosecond NOT, AND, OR, XOR, and the universal NAND and NOR logic gates

  12. Anomalous bioaccumulation of lead in the earthworm Eisenoides lonnbergi (Michaelsen)

    Science.gov (United States)

    Beyer, W. Nelson; Codling, Eton E.; Rutzke, Michael A.

    2018-01-01

    Lead concentrations in soil organisms are usually well below those in the associated soil and tend to decrease with each higher trophic level in a food chain. Earthworms of the species Eisenoides lonnbergi provide an exception to this observation, accumulating very high concentrations of lead from acidic soils. Earthworms belonging to this species were collected from strongly to extremely acidic soils at 16 sites on a wildlife refuge in Maryland, USA. A lead concentration as high as 766 mg/kg, dry weight, was detected in depurated E. lonnbergi collected from soil containing only 17 mg/kg of lead. Concentration factors (ratio of lead concentration in earthworms to lead concentration in soil, dry wt) were highly variable at the sites, from 1.0 to 83. As suggested previously, lead absorption by earthworms is enhanced in low-calcium soils. The anomalously high concentrations of lead found in E. lonnbergi are more closely correlated with the uptake of calcium from acidic soils than with bioaccessibility of soil lead

  13. Investigating the variability in brown carbon light-absorption properties

    Science.gov (United States)

    Saleh, R.; Cheng, Z.; Atwi, K.

    2017-12-01

    Combustion of biomass fuels contributes a significant portion of brown carbon (BrC), the light-absorbing fraction of organic aerosols. BrC exhibits highly variable light-absorption properties, with imaginary part of the refractive indices (k) reported in the literature varying over two orders of magnitude. This high variability in k is attributed to the chaotic nature of combustion; however, there is a major gap in the fundamental understanding of this variability. To address this gap, we hypothesize that BrC is comprised of black carbon (BC) precursors whose transformation to BC has not seen fruition. Depending on the combustion conditions, these BC precursors exhibit different maturity levels which dictate their light-absorption properties (k). The more mature are the precursors, the more absorptive (or BC-like) they are. Therefore, k of BrC obtained from a certain measurement depends on the specific combustion conditions associated with the measurement, leading to the aforementioned variability in the literature. To test this hypothesis, we performed controlled combustion experiments in which the combustion conditions (temperature and air/fuel ratio) were varied and k was retrieved from real-time multi-wavelength light-absorption measurements at each condition. We used benzene, the inception of which during combustion is the initial critical step leading to BC formation, as a model fuel. By varying the combustion conditions from relatively inefficient (low temperature and/or air/fuel ratio) to relatively efficient (high temperature and/or air/fuel ratio), we isolated BrC components with progressively increasing k, spanning the wide range reported in the literature. We also performed thermodenuder measurements to constrain the volatility of the BrC, as well as laser desorption ionization mass spectrometry analysis to constrain its molecular mass. We found that as the combustion conditions approached the BC-formation threshold, the increase in k was associated

  14. Physical properties of the interstellar medium using high-resolution Chandra spectra: O K-edge absorption

    Energy Technology Data Exchange (ETDEWEB)

    Gatuzz, E.; Mendoza, C. [Centro de Física, Instituto Venezolano de Investigaciones Científicas (IVIC), P.O. Box 20632, Caracas 1020A (Venezuela, Bolivarian Republic of); García, J. [Harvard-Smithsonian Center for Astrophysics, MS-6, 60 Garden Street, Cambridge, MA 02138 (United States); Kallman, T. R. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Bautista, M. A.; Gorczyca, T. W., E-mail: egatuzz@ivic.gob.ve, E-mail: claudio@ivic.gob.ve, E-mail: javier@head.cfa.harvard.edu, E-mail: manuel.bautista@wmich.edu, E-mail: thomas.gorczyca@wmich.edu, E-mail: timothy.r.kallman@nasa.gov [Department of Physics, Western Michigan University, Kalamazoo, MI 49008 (United States)

    2014-08-01

    Chandra high-resolution spectra toward eight low-mass Galactic binaries have been analyzed with a photoionization model that is capable of determining the physical state of the interstellar medium. Particular attention is given to the accuracy of the atomic data. Hydrogen column densities are derived with a broadband fit that takes into account pileup effects, and in general are in good agreement with previous results. The dominant features in the oxygen-edge region are O I and O II Kα absorption lines whose simultaneous fits lead to average values of the ionization parameter of log ξ = –2.90 and oxygen abundance of A{sub O} = 0.70. The latter is given relative to the standard by Grevesse and Sauval, but rescaling with the revision by Asplund et al. would lead to an average abundance value fairly close to solar. The low average oxygen column density (N{sub O} = 9.2 × 10{sup 17} cm{sup –2}) suggests a correlation with the low ionization parameters, the latter also being in evidence in the column density ratios N(O II)/N(O I) and N(O III)/N(O I) that are estimated to be less than 0.1. We do not find conclusive evidence for absorption by any other compound but atomic oxygen in our oxygen-edge region analysis.

  15. Moderator Configuration Options for ESS

    DEFF Research Database (Denmark)

    Zanini, L.; Batkov, K.; Klinkby, Esben Bryndt

    2016-01-01

    The current, still evolving status of the design and the optimization work for the moderator configuration for the European Spallation Source is described. The moderator design has been strongly driven by the low-dimensional moderator concept recently proposed for use in spallation neutron sources...... or reactors. Quasi-two dimensional, disc- or tube-shaped moderators,can provide strong brightness increase (factor of 3 or more) with respect to volume para-H2moderators, which constitute the reference, state-of-the-art technology for high-intensity coupled moderators. In the design process other, more...... conventional, principles were also considered,such as the importance of moderator positioning, of the premoderator, and beam extraction considerations. Different design and configuration options are evaluated and compared with the reference volume moderator configuration described in the ESS Technical Design...

  16. Low-field microwave absorption and magnetoresistance in iron nanostructures grown by electrodeposition on n-type lightly doped silicon substrates

    Energy Technology Data Exchange (ETDEWEB)

    Felix, J.F. [Universidade Federal de Viçosa-UFV, Departamento de Física, 36570-900 Viçosa, MG (Brazil); Universidade de Brasília-UnB, Instituto de Física, Núcleo de Física Aplicada, 70910-900 Brasília, DF (Brazil); Figueiredo, L.C. [Universidade de Brasília-UnB, Instituto de Física, Núcleo de Física Aplicada, 70910-900 Brasília, DF (Brazil); Mendes, J.B.S. [Universidade Federal de Viçosa-UFV, Departamento de Física, 36570-900 Viçosa, MG (Brazil); Morais, P.C. [Universidade de Brasília-UnB, Instituto de Física, Núcleo de Física Aplicada, 70910-900 Brasília, DF (Brazil); Huazhong University of Science and Technology, School of Automation, 430074 Wuhan (China); Araujo, C.I.L. de., E-mail: dearaujo@ufv.br [Universidade de Brasília-UnB, Instituto de Física, Núcleo de Física Aplicada, 70910-900 Brasília, DF (Brazil)

    2015-12-01

    In this study we investigate magnetic properties, surface morphology and crystal structure in iron nanoclusters electrodeposited on lightly doped (100) n-type silicon substrates. Our goal is to investigate the spin injection and detection in the Fe/Si lateral structures. The samples obtained under electric percolation were characterized by magnetoresistive and magnetic resonance measurements with cycling the sweeping applied field in order to understand the spin dynamics in the as-produced samples. The observed hysteresis in the magnetic resonance spectra, plus the presence of a broad peak in the non-saturated regime confirming the low field microwave absorption (LFMA), were correlated to the peaks and slopes found in the magnetoresistance curves. The results suggest long range spin injection and detection in low resistive silicon and the magnetic resonance technique is herein introduced as a promising tool for analysis of electric contactless magnetoresistive samples. - Highlights: • Electrodeposition of Fe nanostructures on high resistive silicon substrates. • Spin polarized current among clusters through Si suggested by isotropic magnetoresistance. • Low field microwave absorption arising from the sample shape anisotropy. • Contactless magnetoresistive device characterization by resonance measurements.

  17. [Prenatal lead exposure related to cord blood brain derived neurotrophic factor (BDNF) levels and impaired neonatal neurobehavioral development].

    Science.gov (United States)

    Ren, L H; Mu, X Y; Chen, H Y; Yang, H L; Qi, W

    2016-06-01

    To explore the relationship between umbilical cord blood brain-derived neurotrophic factor (BDNF) and neonatal neurobehavioral development in lead exposure infants. All infants and their mother were randomly selected during 2011 to 2012, subjects were selected according to the umbilical cord blood lead concentrations, which contcentration of lead was higher than 0.48 μmol/L were taken into high lead exposure group, about 60 subjects included. Comparing to the high lead exposure group, according to gender, weight, pregnant week, length and head circumferenece, the level of cord blood lead concentration under 0.48 μmol/L were taken into control group, 60 cases included. Lead content was determined by graphite furnace atomic absorption spectrometry. Neonatal behavioral neurological assessment (NBNA) was used to determine the development of neonatal neuronal behavior. The content of BDNF was detected by ELISA. Comparing the BDNF and the NBNA score between two groups, and linear correlation was given on analysis the correlation between lead concentration in cord blood and BDNF, BDNF and the NBNA score. Lead content in high exposure group was (0.613±0.139) μmol/L, and higher than (0.336±0.142) μmol/L in low exposure group (t=3.21, PBDNF content in high exposure group which was (3.538±1.203) ng/ml was higher than low exposure group (2.464±0.918) ng/ml (t=7.60, PBDNF content was negatively correlated with NBNA summary score, passive muscle tension and active muscle tone score (r was -0.27, -0.29, -0.30, respectively, P values were BDNF was negatively correlated with neonatal neurodevelopment, may serve as a useful biomarker.

  18. Conceptual design of a cold methane moderator system for the European Spallation Source (ESS)

    CERN Document Server

    Barnert-Wiemer, H

    2002-01-01

    As part of the work for the target station of the planned European spallation source (ESS) the Central Department of Technology at the Forschungszentrum Juelich GmbH is also concerned with the moderators, particular attention being given to the development of cold methane moderators. This report discusses the technical feasibility of solid methane moderators. Methods to tailor the neutron output by adding absorption materials (decouplers or poisons) are not considered here, neither are composite moderators. Based on the given target-moderator-reflector assembly of the ESS project a concept for the ESS cold methane moderators has been developed and is being examined at the Forschungszentrum Juelich. According to this moderator concept the moderator is a fixed bed of small spheres, which makes moderator container filling homogeneous and reproducible. Since spheres form a defined packed bed, cooling of the moderator bed by H sub 2 is reliable. The process of filling the moderator container and of removing the pe...

  19. Moderating influence of dominant attentional style and exercise intensity on responses to asynchronous music.

    Science.gov (United States)

    Hutchinson, Jasmin C; Karageorghis, Costas I

    2013-12-01

    We examined independent and combined influences of asynchronous music and dominant attentional style (DAS) on psychological and psychophysical variables during exercise using mixed methods. Participants (N = 34) were grouped according to DAS and completed treadmill runs at three intensities (low, moderate, high) crossed with three music conditions (motivational, oudeterous, no-music control). State attentional focus shifted from dissociative to associative with increasing intensity and was most aligned with DAS during moderate-intensity exercise. Both music conditions facilitated dissociation at low-to-moderate intensities. At high exercise intensity, both music conditions were associated with reduced RPE among participants with an associative DAS. Dissociators reported higher RPE overall during moderate and high intensities. Psychological responses were most positive in the motivational condition, followed by oudeterous and control. Findings illustrate the relevance of individual differences in DAS as well as task intensity and duration when selecting music for exercise.

  20. Effects of using kaolin waste and granite waste as raw materials for the production of low-water absorption ceramic tiles

    International Nuclear Information System (INIS)

    Freires, H.P.; Argonz, R.; Nogueira, R.E.F.Q.; Sasaki, J.M.; Sales, J.C.

    2012-01-01

    This study aims to evaluate the potential of co-use of granite waste (Rain Forest) and kaolin waste as raw material for the manufacture of ceramic coating of low water absorption. Raw materials were characterized by X-ray diffraction. Kaolin residue was added to the residue of granite in the following proportions (in wt%): 0, 10, 20, 30, 40 and 50%. Specimens were fabricated by uniaxial pressing and fired at 1175,1200 and 1225 deg C. Studies of firing linear shrinkage, water absorption, apparent porosity, apparent density and tensile bending test (or rupture modulus) were conducted. The temperature of 1225 deg C allowed the use of a mixture of 50% granite residue and 50% kaolin residue. Ceramic parts made from that mixture exhibited the maximum values required by the Brazilian Standard NBR 13818 for water absorption, shrinkage and density. (author)

  1. Lack of exercise of "moderate to vigorous" intensity in people with low levels of physical activity is a major discriminant for sociodemographic factors and morbidity.

    Directory of Open Access Journals (Sweden)

    José A Serrano-Sánchez

    Full Text Available The aim is to examine the differences between participation at low and zero moderate to vigorous physical activity (MVPA in relation to their trends and associations with known socio-demographic and health factors. We hypothesised that the number of people at zero MVPA level could be rising despite a parallel increase in the population meeting the recommended MVPA level. We also hypothesised that graded associations of sociodemographic and health factors exist across MVPA levels.Two independent population-based samples (n = 4320 [2004] and n = 2176 [1997], were recruited with a stratified and random sampling procedure and interviewed at home by professional interviewers. The MVPA was assessed by validated questionnaire. The participants were classified into three MVPA levels: zero, low and recommended MVPA. The trend of each MVPA level was analysed with the standardized prevalence ratios. Correlates of low and zero MVPA levels were examined using multinomial logistic regression.The population at zero and recommended MVPA levels rose between 1997-2004 by 12% (95% CI, 5-20% and 7% (95% CI,-4-19% respectively, while the population at low MVPA level decreased. At zero MVPA level, associative patterns were observed with sociodemographic and health factors which were different when compared to the population at low MVPA level.Despite the slight increase of population meeting the recommended MVPA level, a higher trend of increase was observed at zero MVPA level. Both recommended and low MPVA levels increased their participation by absorbing participants from the low MVPA level. The sociodemographic profile of those with low MVPA was more similar to the population at recommended MVPA than at zero MVPA level. Methodological implications about the combination of light and moderate-intensity PA could be derived. The prevention of decline in actual low MVPA could change the trend of increase in the population at zero MVPA level, particularly among

  2. Backreflectance from the blood plexus in the skin under the low-power laser heating

    Energy Technology Data Exchange (ETDEWEB)

    Naumenko, E.K. [Institute of Physics National Academy of Sciences of Belarus, Nezavisimosti Avenue, 68, 220072 Minsk (Belarus); Korolevich, A.N. [Institute of Physics National Academy of Sciences of Belarus, Nezavisimosti Avenue, 68, 220072 Minsk (Belarus) and Physics Department, Minho University, Campus Gualtar, 4709 Braga (Portugal)]. E-mail: akaralevich@fisica.uminho.pt; Dubina, N.S. [GP ' MTZ Medservice' , Stahanovskaia Street, 10A, 220009 Minsk (Belarus); Vecherinsky, S.I. [GP ' MTZ Medservice' , Stahanovskaia Street, 10A, 220009 Minsk (Belarus); Belsley, M. [Physics Department, Minho University, Campus Gualtar, 4709 Braga (Portugal)

    2007-07-15

    The intensity of light backscattered when low-power laser radiation is incident on the skin is investigated in vivo. The exposure of blood to low-power laser light in the absorption range of haemoglobin leads to an increased intensity of the backscattered light. The theoretical calculation using the existing optical model of erythrocyte aggregation suggests that the fragmentation of erythrocyte aggregates is the most probable mechanism leading to the enhanced backscattering.

  3. In Everything Moderation

    Centers for Disease Control (CDC) Podcasts

    For many people, drinking alcohol is a regular part of social occasions, but moderation is important. Excessive alcohol consumption can lead to serious health and social problems. A recent report found that binge drinking is common among women and girls. In this podcast, Dr. Dafna Kanny discusses the dangers of binge drinking.

  4. Lithium absorption by the rabbit gall-bladder

    DEFF Research Database (Denmark)

    Hansen, C P; Holstein-Rathlou, N H; Skøtt, O

    1991-01-01

    Lithium (Li+) absorption across the low-resistance epithelium of the rabbit gall-bladder was studied in order to elucidate possible routes and mechanisms of Li+ transfer. Li+ at a concentration of 0.4 mM in both mucosal and serosal media did not affect isosmotic mucosa-to-serosa fluid absorption...... was elicited from the mucosal side and was not accounted for by compensatory Li+ absorption; water and Na+ absorption rates decreased nearly in parallel. The effects of 0.4 mM amiloride and of substitution with 20 mM Li+ were only partly additive. It is concluded that Li+ absorption in the rabbit gall...

  5. Spices as a source of lead exposure: a market-basket survey in Sri Lanka.

    Science.gov (United States)

    Senanayake, M P; Perera, R; Liyanaarachchi, L A; Dassanayake, M P

    2013-12-01

    We performed a laboratory analysis of spices sold in Sri Lanka for lead content. Samples of curry powder, chili powder and turmeric powder from seven provinces, collected using the market basket survey method, underwent atomic absorption spectrometry. Blanks and standards were utilised for instrument calibration and measurement accuracy. The results were validated in two different laboratories. All samples were found to have lead levels below the US Food and Drug Administration's action level of 0.5 μg/g. Spices sold in Sri Lanka contain lead concentrations that are low and within the stipulated safety standards.

  6. All-Optical Wavelength Conversion by Picosecond Burst Absorption in Colloidal PbS Quantum Dots.

    Science.gov (United States)

    Geiregat, Pieter; Houtepen, Arjan J; Van Thourhout, Dries; Hens, Zeger

    2016-01-26

    All-optical approaches to change the wavelength of a data signal are considered more energy- and cost-effective than current wavelength conversion schemes that rely on back and forth switching between the electrical and optical domains. However, the lack of cost-effective materials with sufficiently adequate optoelectronic properties hampers the development of this so-called all-optical wavelength conversion. Here, we show that the interplay between intraband and band gap absorption in colloidal quantum dots leads to a very strong and ultrafast modulation of the light absorption after photoexcitation in which slow components linked to exciton recombination are eliminated. This approach enables all-optical wavelength conversion at rates matching state-of-the-art convertors in speed, yet with cost-effective solution-processable materials. Moreover, the stronger light-matter interaction allows for implementation in small-footprint devices with low switching energies. Being a generic property, the demonstrated effect opens a pathway toward low-power integrated photonics based on colloidal quantum dots as the enabling material.

  7. Aerosol Absorption Measurements in MILAGRO.

    Science.gov (United States)

    Gaffney, J. S.; Marley, N. A.; Arnott, W. P.; Paredes-Miranda, L.; Barnard, J. C.

    2007-12-01

    During the month of March 2006, a number of instruments were used to determine the absorption characteristics of aerosols found in the Mexico City Megacity and nearby Valley of Mexico. These measurements were taken as part of the Department of Energy's Megacity Aerosol Experiment - Mexico City (MAX-Mex) that was carried out in collaboration with the Megacity Interactions: Local and Global Research Observations (MILAGRO) campaign. MILAGRO was a joint effort between the DOE, NSF, NASA, and Mexican agencies aimed at understanding the impacts of a megacity on the urban and regional scale. A super-site was operated at the Instituto Mexicano de Petroleo in Mexico City (designated T-0) and at the Universidad Technologica de Tecamac (designated T-1) that was located about 35 km to the north east of the T-0 site in the State of Mexico. A third site was located at a private rancho in the State of Hidalgo approximately another 35 km to the northeast (designated T-2). Aerosol absorption measurements were taken in real time using a number of instruments at the T-0 and T-1 sites. These included a seven wavelength aethalometer, a multi-angle absorption photometer (MAAP), and a photo-acoustic spectrometer. Aerosol absorption was also derived from spectral radiometers including a multi-filter rotating band spectral radiometer (MFRSR). The results clearly indicate that there is significant aerosol absorption by the aerosols in the Mexico City megacity region. The absorption can lead to single scattering albedo reduction leading to values below 0.5 under some circumstances. The absorption is also found to deviate from that expected for a "well-behaved" soot anticipated from diesel engine emissions, i.e. from a simple 1/lambda wavelength dependence for absorption. Indeed, enhanced absorption is seen in the region of 300-450 nm in many cases, particularly in the afternoon periods indicating that secondary organic aerosols are contributing to the aerosol absorption. This is likely due

  8. Negative affect, negative urgency, thought suppression, and bulimic symptoms: a moderated mediation analysis in a sample at-risk for bulimic symptoms.

    Science.gov (United States)

    Lavender, Jason M; Green, Daniel; Anestis, Michael D; Tull, Matthew T; Gratz, Kim L

    2015-05-01

    Research suggests that negative affect, negative urgency, and thought suppression are related to bulimic symptoms, either directly or indirectly. This study examined associations between these constructs in a sample at-risk for bulimic symptoms. Participants (N = 80) recruited from a residential substance abuse treatment facility completed self-report questionnaires. A regression-based bootstrapping approach was used to examine the indirect effect of negative affect on bulimic symptoms through negative urgency and the moderating role of thought suppression in the association between negative affect and negative urgency. Results revealed a significant indirect effect, significant moderation, and a significant moderated mediation effect, with an indirect effect of negative affect on bulimic symptoms through negative urgency, conditional upon low to moderate (but not high) levels of thought suppression. These findings suggest that negative affect may promote rash actions, particularly in the context of low to moderate thought suppression, leading to increased risk of bulimic symptoms. Copyright © 2015 John Wiley & Sons, Ltd and Eating Disorders Association.

  9. Characterization of the electromagnetic near-field absorption in layered biological tissue in the frequency range from 30 MHz to 6000 MHz

    Energy Technology Data Exchange (ETDEWEB)

    Christ, A [Foundation for Research on Information Technologies in Society (IT' IS), Zeughausstr 43, 8004 Zurich (Switzerland); Samaras, T [Radiocommunications Laboratory, Aristotle University of Thessaloniki, 541 24 Thessaloniki (Greece); Klingenboeck, A [Foundation for Research on Information Technologies in Society (IT' IS), Zeughausstr 43, 8004 Zurich (Switzerland); Kuster, N [Foundation for Research on Information Technologies in Society (IT' IS), Zeughausstr 43, 8004 Zurich (Switzerland)

    2006-10-07

    Currently, standards for the compliance testing of wireless devices are being extended to cover a wider frequency band and different usage patterns of mobile phones as well as of novel body-worn and handheld devices. As a consequence, not only the head but also strongly varying tissue distributions of the body are exposed to electromagnetic radiation. Several authors have reported changes in the SAR absorption of body tissue due to the presence of a low permittivity fat layer. This paper identifies two different effects which can lead to increased SAR in layered tissue in comparison to the SAR assessed using homogeneous tissue simulating liquid: (1) for larger distances between the tissue and the antenna, standing wave effects occur depending on the frequency and fat layer thickness. (2) In the very close near-field (distances approximately {lambda}/40), reactive E-field components lead to high local absorption in the skin. The latter effect occurs at lower frequencies and depends on the antenna type. Modification of the parameters of the homogeneous liquids cannot compensate for these effects. However, a conservative exposure estimate can be obtained by applying a multiplication factor between 1 and 3 to the values assessed using current experimental dosimetric techniques.

  10. Moderator for nuclear reactor

    International Nuclear Information System (INIS)

    Milgram, M.S.; Dunn, J.T.; Hart, R.S.

    1995-01-01

    This invention relates to a moderator for a nuclear reactor and more specifically, to a composite moderator. A moderator is designed to slow down, or thermalize, neutrons which are released during nuclear reactions in the reactor fuel. Pure or almost pure materials like light water, heavy water, beryllium or graphite are used singly as moderators at present. All these materials, are used widely. Graphite has a good mechanical strength at high temperatures encountered in the nuclear core and therefore is used as both the moderator and core structural material. It also exhibits a low neutron-capture cross section and high neutron scattering cross section. However, graphite is susceptible to attach by carbon dioxide and/or oxygen where applicable, and releases stress energy under certain circumstances, although under normal operating conditions these reactions can be controlled. (author). 1 tab

  11. Comparisons of low-intensity versus moderate-intensity combined aerobic and resistance training on body composition, muscle strength, and functional performance in older women.

    Science.gov (United States)

    Shiotsu, Yoko; Yanagita, Masahiko

    2018-06-01

    This study aimed to examine the effects of exercise order of combined aerobic and low- or moderate-intensity resistance training into the same session on body composition, functional performance, and muscle strength in healthy older women. Furthermore, this study compared the effects of different (low- vs moderate-) intensity combined training. A total of 60 healthy older women (age 61-81 y) were randomly assigned to five groups that performed aerobic exercise before low-intensity resistance training (AR-L, n = 12) or after resistance training (RA-L, n = 12), performed aerobic exercise before moderate-intensity resistance training (AR-M, n = 12) or after resistance training (RA-M, n = 12), or nonintervention control conditions (CON, n = 12). Body composition, functional performance, and muscle strength were evaluated before and after the 10-week training. No effects of exercise order of combined aerobic and low- or moderate-intensity resistance training (AR-L vs RA-L, AR-M vs RA-M) were observed in body composition, functional performance, or muscle strength, whereas the effects of training intensity of combined training (AR-L vs AR-M, RA-L vs RA-M) were observed on functional performance. All combined trainings significantly increased muscle strength and gait ability (P Functional reach test significantly increased in the AR-M and RA-M groups (P training increases muscle strength and improves gait ability, regardless of the exercise order. Also, greater improvement in dynamic balance capacity, a risk factor associated with falling, is observed in moderate-intensity combined training.

  12. High-efficiency ventilated metamaterial absorber at low frequency

    Science.gov (United States)

    Wu, Xiaoxiao; Au-Yeung, Ka Yan; Li, Xin; Roberts, Robert Christopher; Tian, Jingxuan; Hu, Chuandeng; Huang, Yingzhou; Wang, Shuxia; Yang, Zhiyu; Wen, Weijia

    2018-03-01

    We demonstrate a ventilated metamaterial absorber operating at low frequency (90%) has been achieved in both simulations and experiments. This high-efficiency absorption under the ventilation condition originates from the weak coupling of two identical split tube resonators constituting the absorber, which leads to the hybridization of the degenerate eigenmodes and breaks the absorption upper limit of 50% for conventional transmissive symmetric acoustic absorbers. The absorber can also be extended to an array and work in free space. The absorber should have potential applications in acoustic engineering where both noise reduction and ventilation are required.

  13. Efficacy and safety of transcatheter aortic valve replacement in aortic stenosis patients at low to moderate surgical risk: a comprehensive meta-analysis

    OpenAIRE

    Elmaraezy, Ahmed; Ismail, Ammar; Abushouk, Abdelrahman Ibrahim; Eltoomy, Moutaz; Saad, Soha; Negida, Ahmed; Abdelaty, Osama Mahmoud; Abdallah, Ahmed Ramadan; Aboelfotoh, Ahmed Magdy; Hassan, Hossam Mahmoud; Elmaraezy, Aya Gamal; Morsi, Mahmoud; Althaher, Farah; Althaher, Moath; AlSafadi, Ammar M.

    2017-01-01

    Background Recently, transcatheter aortic valve replacement (TAVR) has become the procedure of choice in high surgical risk patients with aortic stenosis (AS). However, its value is still debated in operable AS cases. We performed this meta-analysis to compare the safety and efficacy of TAVR to surgical aortic valve replacement (SAVR) in low-to-moderate surgical risk patients with AS. Methods A systematic search of five authentic databases retrieved 11 eligible studies (20,056 patients). Rele...

  14. Low blood flow at onset of moderate-intensity exercise does not limit muscle oxygen uptake

    DEFF Research Database (Denmark)

    Nyberg, Michael Permin; Mortensen, Stefan P; Saltin, Bengt

    2010-01-01

    The effect of low blood flow at onset of moderate-intensity exercise on the rate of rise in muscle oxygen uptake was examined. Seven male subjects performed a 3.5-min one-legged knee-extensor exercise bout (24 +/- 1 W, mean +/- SD) without (Con) and with (double blockade; DB) arterial infusion...... of inhibitors of nitric oxide synthase (N(G)-monomethyl-l-arginine) and cyclooxygenase (indomethacin) to inhibit the synthesis of nitric oxide and prostanoids, respectively. Leg blood flow and leg oxygen delivery throughout exercise was 25-50% lower (P ... +/- 12 vs. 262 +/- 39 ml/min). The present data demonstrate that muscle blood flow and oxygen delivery can be markedly reduced without affecting muscle oxygen uptake in the initial phase of moderate-intensity exercise, suggesting that blood flow does not limit muscle oxygen uptake at the onset...

  15. Effects of Low Versus Moderate Glycemic Index Diets on Aerobic Capacity in Endurance Runners: Three-Week Randomized Controlled Crossover Trial

    Directory of Open Access Journals (Sweden)

    Krzysztof Durkalec-Michalski

    2018-03-01

    Full Text Available The glycemic index (GI of ingested carbohydrates may influence substrate oxidation during exercise and athletic performance. Therefore, the aim of this study was to assess the effect of low- and moderate-GI three-week diets on aerobic capacity and endurance performance in runners. We conducted a randomized crossover feeding study of matched diets differing only in GI (low vs. moderate in 21 endurance-trained runners. Each participant consumed both, low- (LGI and moderate-GI (MGI high-carbohydrate (~60% and nutrient-balanced diets for three weeks each. At the beginning and end of each diet, participants had their aerobic capacity and body composition measured and performed a 12-min running test. After LGI, time to exhaustion during incremental cycling test (ICT and distance covered in the 12-min run were significantly increased. The MGI diet led to an increase in maximal oxygen uptake ( V ˙ O2max, but no performance benefits were found after the MGI diet. The LGI and MGI diets improved time and workload at gas exchange threshold (GET during ICT. The results indicate that a three-week high-carbohydrate LGI diet resulted in a small but significant improvement in athletic performance in endurance runners. Observed increase in V ˙ O2max on MGI diet did not affect performance.

  16. Separation/preconcentration of silver(I) and lead(II) in environmental samples on cellulose nitrate membrane filter prior to their flame atomic absorption spectrometric determinations

    International Nuclear Information System (INIS)

    Soylak, Mustafa; Cay, Rukiye Sungur

    2007-01-01

    An enrichment method for trace amounts of Ag(I) and Pb(II) has been established prior to their flame atomic absorption spectrometric determinations. The preconcentration/separation procedure is based on chelate formation of Ag(I) and Pb(II) with ammonium pyrrolidine dithiocarbamate (APDC) and on retention of the chelates on cellulose nitrate membrane filter. The influences of some analytical parameters including pH and amounts of reagent, etc. on the recoveries of analytes were investigated. The effects of interferic ions on the quantitative recoveries of analytes were also examined. The detection limits (k = 3, N = 11) were 4.6 μg L -1 for silver(I) and 15.3 μg L -1 for lead(II). The relative standard deviations (R.S.D.) of the determinations for analyte ions were below 3%. The method was applied to environmental samples for the determination of analyte ions with satisfactory results (recoveries >95%)

  17. Mild to Moderate Alzheimer Dementia with Insufficient Neuropathological Changes

    Science.gov (United States)

    Serrano-Pozo, Alberto; Qian, Jing; Monsell, Sarah E.; Blacker, Deborah; Gómez-lsla, Teresa; Betensky, Rebecca A.; Growdon, John H.; Johnson, Keith; Frosch, Matthew P.; Sperling, Reisa A.; Hyman, Bradley T.

    2014-01-01

    Recently, ∼16% of participants in an anti-Aβ passive immunotherapy trial for mild-to-moderate Alzheimer disease (AD) had a negative baseline amyloid positron emission tomography (PET) scan. Whether they have AD or are AD clinical phenocopies remains unknown. We examined the 2005-2013 National Alzheimer's Coordinating Center autopsy database and found that ∼14% of autopsied subjects clinically diagnosed with mild-to-moderate probable AD have no or sparse neuritic plaques, which would expectedly yield a negative amyloid PET scan. More than half of these “Aβ-negative” subjects have low neurofibrillary tangle Braak stages. These findings support the implementation of a positive amyloid biomarker as an inclusion criterion in future anti-Aβ drug trials. PMID:24585367

  18. Maternal low-protein diet-induced delayed reflex ontogeny is attenuated by moderate physical training during gestation in rats.

    Science.gov (United States)

    Falcão-Tebas, Filippe; Bento-Santos, Adriano; Fidalgo, Marco Antônio; de Almeida, Marcelus Brito; dos Santos, José Antônio; Lopes de Souza, Sandra; Manhães-de-Castro, Raul; Leandro, Carol Góis

    2012-02-01

    We evaluated the effects of moderate- to low-intensity physical training during gestation on reflex ontogeny in neonate rats whose mothers were undernourished. Virgin female Wistar rats were divided into four groups as follows: untrained (NT, n 7); trained (T, n 7); untrained with a low-protein diet (NT+LP, n 7); trained with a low-protein diet (T+LP, n 4). Trained rats were subjected to a protocol of moderate physical training on a treadmill over a period of 4 weeks (5 d/week and 60 min/d, at 65 % of VO₂max). After confirming the pregnancy, the intensity and duration of the exercise were reduced. Low-protein groups were provided with an 8 % casein diet, and controls were provided with a 17 % casein diet. Their respective offspring were evaluated (during the 10th-17th days of postnatal life) in terms of physical feature maturation, somatic growth and reflex ontogeny. Pups born to mothers provided with the low-protein diet during gestation and lactation showed delayed physical feature and reflex maturation and a deficit in somatic growth when compared with controls. However, most of these deficiencies were attenuated in pups of undernourished mothers undergoing training. In conclusion, physical training during gestation attenuates the effects of perinatal undernutrition on some patterns of maturation in the central nervous system during development.

  19. Iron K Features in the Quasar E 1821+643: Evidence for Gravitationally Redshifted Absorption?

    Science.gov (United States)

    Yaqoob, Tahir; Serlemitsos, Peter

    2005-01-01

    We report a Chandra high-energy grating detection of a narrow, redshifted absorption line superimposed on the red wing of a broad Fe K line in the z = 0.297 quasar E 1821+643. The absorption line is detected at a confidence level, estimated by two different methods, in the range approx. 2 - 3 sigma. Although the detection significance is not high enough to exclude a non-astrophysical origin, accounting for the absorption feature when modeling the X-ray spectrum implies that the Fe-K emission line is broad, and consistent with an origin in a relativistic accretion disk. Ignoring the apparent absorption feature leads to the conclusion that the Fe-K emission line is narrower, and also affects the inferred peak energy of the line (and hence the inferred ionization state of Fe). If the absorption line (at approx. 6.2 keV in the quasar frame) is real, we argue that it could be due to gravitationally redshifted Fe XXV or Fe XXVI resonance absorption within approx. 10 - 20 gravitational radii of the putative central black hole. The absorption line is not detected in earlier ASCA and Chandra low-energy grating observations, but the absorption line is not unequivocally ruled out by these data. The Chandra high-energy grating Fe-K emission line is consistent with an origin predominantly in Fe I-XVII or so. In an ASCA observation eight years earlier, the Fe-K line peaked at approx. 6.6 keV, closer to the energies of He-like Fe triplet lines. Further, in a Chandra low-energy grating observation the Fe-K line profile was double-peaked, one peak corresponding to Fe I-XVII or so, the other peak to Fe XXVI Ly alpha. Such a wide range in ionization state of Fe is not ruled out by the HEG and ASCA data either, and is suggestive of a complex structure for the line-emitter.

  20. Parameter study of self-absorption effects in Total Reflection X-ray Fluorescence-X-ray Absorption Near Edge Structure analysis of arsenic

    International Nuclear Information System (INIS)

    Meirer, F.; Pepponi, G.; Streli, C.; Wobrauschek, P.; Kregsamer, P.; Zoeger, N.; Falkenberg, G.

    2008-01-01

    Total reflection X-ray Fluorescence (TXRF) analysis in combination with X-ray Absorption Near Edge Structure (XANES) analysis is a powerful method to perform chemical speciation studies at trace element levels. However, when measuring samples with higher concentrations and in particular standards, damping of the oscillations is observed. In this study the influence of self-absorption effects on TXRF-XANES measurements was investigated by comparing measurements with theoretical calculations. As(V) standard solutions were prepared at various concentrations and dried on flat substrates. The measurements showed a correlation between the damping of the oscillations and the As mass deposited. A Monte-Carlo simulation was developed using data of the samples shapes obtained from confocal white light microscopy. The results showed good agreement with the measurements; they confirmed that the key parameters are the density of the investigated atom in the dried residues and the shape of the residue, parameters that combined define the total mass crossed by a certain portion of the incident beam. The study presents a simple approach for an a priori evaluation of the self-absorption in TXRF X-ray absorption studies. The consequences for Extended X-ray Absorption Fine Structure (EXAFS) and XANES measurements under grazing incidence conditions are discussed, leading to the conclusion that the damping of the oscillations seems to make EXAFS of concentrated samples non feasible. For XANES 'fingerprint' analysis samples should be prepared with a deposited mass and sample shape leading to an acceptable absorption for the actual investigation

  1. Magnetic nanoparticles with high specific absorption rate of electromagnetic energy at low field strength for hyperthermia therapy

    Science.gov (United States)

    Shubitidze, Fridon; Kekalo, Katsiaryna; Stigliano, Robert; Baker, Ian

    2015-03-01

    Magnetic nanoparticles (MNPs), referred to as the Dartmouth MNPs, which exhibit high specific absorption rate at low applied field strength have been developed for hyperthermia therapy applications. The MNPs consist of small (2-5 nm) single crystals of gamma-Fe2O3 with saccharide chains implanted in their crystalline structure, forming 20-40 nm flower-like aggregates with a hydrodynamic diameter of 110-120 nm. The MNPs form stable (>12 months) colloidal solutions in water and exhibit no hysteresis under an applied quasistatic magnetic field, and produce a significant amount of heat at field strengths as low as 100 Oe at 99-164 kHz. The MNP heating mechanisms under an alternating magnetic field (AMF) are discussed and analyzed quantitatively based on (a) the calculated multi-scale MNP interactions obtained using a three dimensional numerical model called the method of auxiliary sources, (b) measured MNP frequency spectra, and (c) quantified MNP friction losses based on magneto-viscous theory. The frequency responses and hysteresis curves of the Dartmouth MNPs are measured and compared to the modeled data. The specific absorption rate of the particles is measured at various AMF strengths and frequencies, and compared to commercially available MNPs. The comparisons demonstrate the superior heating properties of the Dartmouth MNPs at low field strengths (therapy to deeper tumors that were previously non-viable targets, potentially enabling the treatment of some of the most difficult cancers, such as pancreatic and rectal cancers, without damaging normal tissue.

  2. Radioisotope investigation of iron absorption in humans. Part of a WHO/IAEA coordinated programme on iron nutrition

    International Nuclear Information System (INIS)

    Bothwell, T.H.

    1975-08-01

    The gastrointestinal absorption of iron was investigated in a number of multiparous women living under low socio-economic conditions which are known to lead commonly to iron deficiency. The percentage absorption was deduced by comparing the concentration of 55 Fe and/or 59 Fe in blood with the activity of the corresponding isotope(s) administered orally about two weeks earlier. It was confirmed or established that: (1) food or supplemental iron, if available at all, tends to be absorbed from the intestines as if present there in one of two alternative pools: heme and non-heme, (2) vitamin C substantially increases absorption of food or supplemental non-heme iron, (3) it is technically possible to use common salt or sugar as a carrier for supplemental iron and vitamin C, but practical difficulties of using such systems in a public health prophylactic programme are severe, and (4) tea, presumably because of its tannin content, inhibits absorption of accompanying iron

  3. Manipulating the loss in electromagnetic cloaks for perfect wave absorption.

    Science.gov (United States)

    Argyropoulos, Christos; Kallos, Efthymios; Zhao, Yan; Hao, Yang

    2009-05-11

    We examine several ways to manipulate the loss in electro-magnetic cloaks, based on transformation electromagnetics. It is found that, by utilizing inherent electric and magnetic losses of metamaterials, perfect wave absorption can be achieved based on several popular designs of electromagnetic cloaks. A practical implementation of the absorber, consisting of ten discrete layers of metamaterials, is proposed. The new devices demonstrate super-absorptivity over a moderate wideband range, suitable for both microwave and optical applications. It is corroborated that the device is functional with a subwavelength thickness and, hence, advantageous compared to the conventional absorbers.

  4. Particulate absorption properties in the Red Sea from hyperspectral particulate absorption spectra

    KAUST Repository

    Tiwari, Surya Prakash

    2018-03-16

    This paper aims to describe the variability of particulate absorption properties using a unique hyperspectral dataset collected in the Red Sea as part of the TARA Oceans expedition. The absorption contributions by phytoplankton (aph) and non-algal particles (aNAP) to the total particulate absorption coefficients are determined using a numerical decomposition method (NDM). The NDM is validated by comparing the NDM derived values of aph and aNAP with simulated values of aph and aNAP are found to be in excellent agreement for the selected wavelengths (i.e., 443, 490, 555, and 676nm) with high correlation coefficient (R2), low root mean square error (RMSE), mean relative error (MRE), and with a slope close to unity. Further analyses showed that the total particulate absorption coefficients (i.e., ap(443)average = 0.01995m−1) were dominated by phytoplankton absorption (i.e., aph(443)average = 0.01743m−1) with a smaller contribution by non-algal particles absorption (i.e., aNAP(443)average = 0.002524m−1). The chlorophyll a is computed using the absorption based Line Height Method (LHM). The derived chlorophyll-specific absorption ((a⁎ph = aph(λ)/ChlLH)) showed more variability in the blue part of spectrum as compared to the red part of spectrum representative of the package effect and changes in pigment composition. A new parametrization proposed also enabled the reconstruction of a⁎ph(λ) for the Red Sea. Comparison of derived spectral constants with the spectral constants of existing models showed that our study A(λ) values are consistent with the existing values, despite there is a divergence with the B(λ) values. This study provides valuable information derived from the particulate absorption properties and its spectral variability and this would help us to determine the relationship between the phytoplankton absorption coefficients and chlorophyll a and its host of variables for the Red Sea.

  5. A low-fat high-carbohydrate diet reduces plasma total adiponectin concentrations compared to a moderate-fat diet with no impact on biomarkers of systemic inflammation in a randomized controlled feeding study.

    Science.gov (United States)

    Song, Xiaoling; Kestin, Mark; Schwarz, Yvonne; Yang, Pamela; Hu, Xiaojun; Lampe, Johanna W; Kratz, Mario

    2016-02-01

    We compared the effects of a eucaloric moderate-fat diet (18% protein, 36% fat, and 46% carbohydrate), a eucaloric low-fat high-carbohydrate diet (18% protein, 18% fat, and 64% carbohydrate), and a low-calorie (33% reduced) low-fat high-carbohydrate diet on biomarkers of systemic inflammation. We randomly assigned 102 participants (age 21-76 years and BMI 19.2-35.5 kg/m(2)) to the three different diets for 6 weeks in a parallel design intervention trial. All foods were provided. Ninety-three participants completed all study procedures; 92 were included in the analyses. Endpoints included plasma C-reactive protein (CRP), interleukin-6 (IL-6), soluble tumor necrosis factor receptors I and II (sTNFRI and II), and adiponectin. In the unadjusted primary analyses, none of the endpoints were differentially affected by the dietary interventions despite the significantly greater reductions in body weight and fat mass in participants consuming the low-calorie low-fat diet compared to the eucaloric diets (p loss (time × weight change interaction, p = 0.051). Adjusted for weight change, adiponectin was reduced in the groups consuming the low-fat diets relative to the moderate-fat diet (p = 0.008). No effect of the intervention diets or weight loss on CRP, IL-6, or sTNFRI and II was seen in these secondary analyses. In relatively healthy adults, moderate weight loss had minimal effects on systemic inflammation, and raised plasma adiponectin only modestly. A lower dietary fat and higher carbohydrate content had little impact on measures of systemic inflammation, but reduced adiponectin concentrations compared to a moderate-fat diet. The latter may be of concern given the consistent and strong inverse association of plasma adiponectin with many chronic diseases.

  6. What to Do With "Moderate" Reliability and Validity Coefficients?

    NARCIS (Netherlands)

    Post, Marcel W

    Clinimetric studies may use criteria for test-retest reliability and convergent validity such that correlation coefficients as low as .40 are supportive of reliability and validity. It can be argued that moderate (.40-.60) correlations should not be interpreted in this way and that reliability

  7. Self-Reported Participation in Sport/Exercise Among Adolescents and Young Adults With and Without Mild to Moderate Intellectual Disability.

    Science.gov (United States)

    Robertson, Janet; Emerson, Eric; Baines, Susannah; Hatton, Chris

    2018-04-01

    Physical inactivity is a leading risk factor for mortality. Adults with intellectual disability are extremely inactive, but less is known about physical activity levels in children and youth with intellectual disability. This paper examines the participation by adolescents and young adults with and without mild to moderate intellectual disability in sport/exercise. Secondary analysis was undertaken of Next Steps, an annual panel study that followed a cohort from early adolescence into adulthood. Participants with mild to moderate intellectual disability were identified through data linkage with educational records. Sport/exercise participation rates were consistently lower for adolescents and young people with mild to moderate intellectual disability than for their peers without intellectual disability. Matching participants on between-group differences in exposure to extraneous risk factors did not impact on these between-group differences in participation in sport/exercise. The results support limited existing evidence regarding the low level of participation of children and young people with intellectual disability in sport/exercise compared with their peers. Future work on promoting sport/exercise and physical activity in children and young people with intellectual disability may play a role in helping to reduce the health inequalities experienced by people with intellectual disability.

  8. Moderator configuration options for a low-enriched uranium fueled Kilowatt-class Space Nuclear Reactor

    International Nuclear Information System (INIS)

    King, Jeffrey C.; Mencarini, Leonardo de Holanda; Guimaraes, Lamartine N. F.

    2015-01-01

    The Brazilian Air Force, through its Institute for Advanced Studies (Instituto de Estudos Avancados, IEAv/DCTA), and the Colorado School of Mines (CSM) are studying the feasibility of a space nuclear reactor with a power of 1-5 kW e and fueled with Low-Enriched Uranium (LEU). This type of nuclear reactor would be attractive to signatory countries of the Non-Proliferation Treaty (NPT) or commercial interests. A LEU-fueled space reactor would avoid the security concerns inherent with Highly Enriched Uranium (HEU) fuel. As an initial step, the HEU-fueled Kilowatt Reactor Using Stirling Technology (KRUSTY) designed by the Los Alamos National Laboratory serves as a basis for a similar reactor fueled with LEU fuel. Using the computational code MCNP6 to predict the reactor neutronics performance, the size of the resulting reactor fueled with 19.75 wt% enriched uranium-10 wt% molybdenum alloy fuel is adjusted to match the excess reactivity of KRUSTY. Then, zirconium hydride moderator is added to the core to reduce the size of the reactor. This work presents the preliminary results of the computational modeling, with special emphasis on the comparison between homogeneous and heterogeneous moderator systems, in terms of the core diameter required to meet a specific multiplication factor (k eff = 1.035). This comparison illustrates the impact of moderator configuration on the size and performance of a LEU-fueled kilowatt-class space nuclear reactor. (author)

  9. Moderator configuration options for a low-enriched uranium fueled Kilowatt-class Space Nuclear Reactor

    Energy Technology Data Exchange (ETDEWEB)

    King, Jeffrey C., E-mail: kingjc@mines.edu [Nuclear Science and Engineering Program, Colorado School of Mines (CSM), Golden, CO (United States); Mencarini, Leonardo de Holanda; Guimaraes, Lamartine N. F., E-mail: guimaraes@ieav.cta.br, E-mail: mencarini@ieav.cta.br [Instituto de Estudos Avancados (IEAV), Sao Jose dos Campos, SP (Brazil). Divisao de Energia Nuclear

    2015-07-01

    The Brazilian Air Force, through its Institute for Advanced Studies (Instituto de Estudos Avancados, IEAv/DCTA), and the Colorado School of Mines (CSM) are studying the feasibility of a space nuclear reactor with a power of 1-5 kW{sub e} and fueled with Low-Enriched Uranium (LEU). This type of nuclear reactor would be attractive to signatory countries of the Non-Proliferation Treaty (NPT) or commercial interests. A LEU-fueled space reactor would avoid the security concerns inherent with Highly Enriched Uranium (HEU) fuel. As an initial step, the HEU-fueled Kilowatt Reactor Using Stirling Technology (KRUSTY) designed by the Los Alamos National Laboratory serves as a basis for a similar reactor fueled with LEU fuel. Using the computational code MCNP6 to predict the reactor neutronics performance, the size of the resulting reactor fueled with 19.75 wt% enriched uranium-10 wt% molybdenum alloy fuel is adjusted to match the excess reactivity of KRUSTY. Then, zirconium hydride moderator is added to the core to reduce the size of the reactor. This work presents the preliminary results of the computational modeling, with special emphasis on the comparison between homogeneous and heterogeneous moderator systems, in terms of the core diameter required to meet a specific multiplication factor (k{sub eff} = 1.035). This comparison illustrates the impact of moderator configuration on the size and performance of a LEU-fueled kilowatt-class space nuclear reactor. (author)

  10. Damped Lyman-alpha absorption by disk galaxies with large redshifts. III. Intermediate-resolution spectroscopy

    International Nuclear Information System (INIS)

    Turnshek, D.A.; Wolfe, A.M.; Lanzetta, K.M.; Briggs, F.H.; Cohen, R.D.

    1989-01-01

    New intermediate-resolution spectroscopy for six members of a sample of 68 moderate- to high-redshift QSOs is presented. Evidence is reported which indicates that seven strong absorption features in the QSO spectra are due to damped Ly-alpha absorption. A standard curve-of-growth analysis on five of the damped systems is performed, and relevant properties are tabulated and discussed. Six of the seven damped Ly-alpha systems have H I column densities of 2 x 10 to the 20th/sq cm or larger, while the remaining system has an H I column density of about 10 to the 20th/sq cm. It is suggested that damped Ly-alpha systems arise when a sight line intercepts a high-redshift protogalaxy disk containing a quiescent cloud component characterized by high column density and low effective velocity dispersion. At the same time, the sight line usually intercepts a broader turbulent component, which is identified as the halo, characterized by much lower column density and higher effective velocity dispersion. 42 refs

  11. Contribution of Bound States to the Harmonic Generation in Hydrogen at Moderate Laser Intensities

    National Research Council Canada - National Science Library

    Davis, Jack

    2002-01-01

    .... The disappearance of bound parabolic states with large electric dipole moments in moderately strong fields leads to the simplification of the expression for the total time-dependent dipole moment of the atom...

  12. Optical and X-ray absorption spectroscopy in lead doped lithium fluoride crystals

    Energy Technology Data Exchange (ETDEWEB)

    Somma, F; Aloe, P; D' Acapito, F; Montereali, R M; Polosan, S; Secu, M; Vincenti, M A, E-mail: somma@fis.uniroma3.it

    2010-11-15

    LiF:Pb doped crystals were successfully grown by Kyropoulos method, starting with drying powders. The presence of Pb{sup 2+} ions in the LiF crystals were evidenced by the absorption band at 278 nm and by 375 nm photoluminescence. The presence of some other Pb structures with oxygen compounds in the as made samples was evidenced, decreasing after some annealing procedures. The local environment and valence state of Pb in LiF were studied by X-ray Absorption Spectroscopy at the Pb L{sub III} and L{sub I} edges. XANES data reveal that Pb is present as Pb{sup 2+} whereas EXAFS data show that it is incorporated in the crystal and not forming PbF{sub 2} precipitates. Identical spectra are obtained for samples as prepared and after thermal annealing up to 650 deg. C demonstrating the stability of the incorporation site. Also the concentration of Pb in the crystal has no effect on the location site of the metal as the same spectrum is obtained for specimens with different dopant concentrations.

  13. Effect of water vapor on sound absorption in nitrogen at low frequency/pressure ratios

    Science.gov (United States)

    Zuckerwar, A. J.; Griffin, W. A.

    1981-01-01

    Sound absorption measurements were made in N2-H2O binary mixtures at 297 K over the frequency/pressure range f/P of 0.1-2500 Hz/atm to investigate the vibrational relaxation peak of N2 and its location on f/P axis as a function of humidity. At low humidities the best fit to a linear relationship between the f/P(max) and humidity yields an intercept of 0.013 Hz/atm and a slope of 20,000 Hz/atm-mole fraction. The reaction rate constants derived from this model are lower than those obtained from the extrapolation of previous high-temperature data.

  14. Lead, arsenic, and copper content of crops grown on lead arsenate-treated and untreated soils

    Energy Technology Data Exchange (ETDEWEB)

    Chisholm, D

    1972-01-01

    Increased lead and arsenic concentrations in the surface soil (0-15 cm), resulting from applications of lead arsenate (PbHAs0/sub 1/), increased both lead and arsenic levels in crops grown on treated plots. The lead levels in some crops approached or exceeded the Canadian residue tolerance of 2.0 ppM. Lead arsenate soil treatments did not affect copper absorption by crops. On areas such as old orchard land contaminated with lead arsenate residues it may be advisable to ascertain crops, and also to determine the lead affinity and arsenic sensitivity of the plants to be grown.

  15. Model for next-to-leading order threshold resummed form factors

    International Nuclear Information System (INIS)

    Aglietti, Ugo; Ricciardi, Giulia

    2004-01-01

    We present a model for next-to-leading order resummed threshold form factors based on a timelike coupling recently introduced in the framework of small x physics. Improved expressions for the form factors in N-space are obtained which are not plagued by Landau-pole singularities, as the included absorptive effects - usually neglected - act as regulators. The physical reason is that, because of faster decay of gluon jets, there is not enough resolution time to observe the Landau pole. Our form factors reduce to the standard ones when the absorptive parts related to the coupling are neglected. The inverse transform from N-space to x-space can be done directly without any prescription and we obtain analytical expressions for the form factors, which are well defined in all x-space

  16. [Determination of trace lead and cadmium in transgenic rice by crosslinked carboxymethyl konjac glucomannan microcolumn preconcentration combined with graphite furnace atomic absorption spectrometry].

    Science.gov (United States)

    Liu, Hua-qing; Li, Sheng-qing; Qu, Yang; Chen, Hao

    2012-02-01

    A novel method was developed for the determination of trace lead and cadmium in transgenic brown rice based on separation and preconcentration with a micro column packed with crosslinked carboxymethyl konjac glucomannan (CCMKGM) prior to its determination by graphite furnace atomic absorption spectrometry. Variables affecting the separation and preconcentration of lead and cadmium, such as the acidity of the aqueous solution, sample flow rate and volume, and eluent concentration and volume, were optimized. Under optimized condition, detection limits of the method for the determination of trace lead and cadmium in transgenic brown rice were 0.11 and 0.002 microg x L(-1), respectively. The obtained results of lead and cadmium in the certified reference material (GBW10010, GBS1-1) were in good agreement with the certified values. The recoveries were in the range of 90%-103% and 93%-105% for detection of Pb and Cd in transgenic brown rice and the wild-type brown rice samples respectively. This study could provide technical support for determination of trace Pb and Cd in transgenic rice.

  17. Lead concentration in meat from lead-killed moose and predicted human exposure using Monte Carlo simulation.

    Science.gov (United States)

    Lindboe, M; Henrichsen, E N; Høgåsen, H R; Bernhoft, A

    2012-01-01

    Lead-based hunting ammunitions are still common in most countries. On impact such ammunition releases fragments which are widely distributed within the carcass. In Norway, wild game is an important meat source for segments of the population and 95% of hunters use lead-based bullets. In this paper, we have investigated the lead content of ground meat from moose (Alces alces) intended for human consumption in Norway, and have predicted human exposure through this source. Fifty-two samples from different batches of ground meat from moose killed with lead-based bullets were randomly collected. The lead content was measured by atomic absorption spectroscopy. The lead intake from exposure to moose meat over time, depending on the frequency of intake and portion size, was predicted using Monte Carlo simulation. In 81% of the batches, lead levels were above the limit of quantification of 0.03 mg kg(-1), ranging up to 110 mg kg(-1). The mean lead concentration was 5.6 mg kg(-1), i.e. 56 times the European Commission limit for lead in meat. For consumers eating a moderate meat serving (2 g kg(-1) bw), a single serving would give a lead intake of 11 µg kg(-1) bw on average, with maximum of 220 µg kg(-1) bw. Using Monte Carlo simulation, the median (and 97.5th percentile) predicted weekly intake of lead from moose meat was 12 µg kg(-1) bw (27 µg kg(-1) bw) for one serving per week and 25 µg kg(-1) bw (45 µg kg(-1) bw) for two servings per week. The results indicate that the intake of meat from big game shot with lead-based bullets imposes a significant contribution to the total human lead exposure. The provisional tolerable weekly intake set by the World Health Organization (WHO) of 25 µg kg(-1) bw is likely to be exceeded in people eating moose meat on a regular basis. The European Food Safety Authority (EFSA) has recently concluded that adverse effects may be present at even lower exposure doses. Hence, even occasional consumption of big game meat with lead levels as

  18. Determination of Effect of Low Dose Vs Moderate Dose of Clofibrate on the Decreasing in Serum Bilirubin Level in the Term Healthy Neonate

    OpenAIRE

    Mohammad Ashkan Moslehi; Narges Pishva

    2007-01-01

    Objective: This study was performed to determine the effect of low doses (25 mg/Kg) vs. moderate doses (50 mg/Kg) of clofibrate in treatment of non-hemolytic hyperbilirubin¬emia in healthy term neonates. Material & Methods: A clinical randomized controlled trial was performed in three groups of healthy term neonates. One group was treated with a single low dose of clofibrate (25 mg/Kg) while another group received a single moderate dose (50mg/kg) both orally plus phototherapy; the results wer...

  19. Improvement of the tetrachloromercurate absorption technique for measuring low atmospheric SO2 mixing ratios

    Science.gov (United States)

    Jaeschke, W.; Beltz, N.; Haunold, W.; Krischke, U.

    1997-07-01

    During the Gas-Phase Sulfur Intercomparison Experiment (GASIE) in 1994 an analytical system for measuring sulfur dioxide mixing ratios at low parts per trillion (pptv) levels was employed. It is based on the absorption of SO2 on a tetrachloromercurate(II)-impregnated filter. The subsequent analysis uses a chemiluminescence reaction by treating the resulting disulfitomercurate(II) complex with an acidic cerium sulfate solution. An improved sampling device has been introduced that increases the maximum sampling volume from 200 L to 500 L. It is also possible to determine the blank value accurately for each sample. The absorption efficiency of the sampling system is 98.7±6.4% at a nominal flow rate of 10 L/min. The calculated (3σ) detection limit is 3±1 pptv SO2. The sample solution is stable for up to 30 days, which allows the samples to be safely stored or shipped before analysis. This permits the use of a sensitive, compact, and reliable sampling system in the field with subsequent analysis under optimal conditions in the laboratory. A continuous flow chemiluminescence (CFCL) analyzer for on-line measurements is also presented. The system is based on the same chemical principles as the described filter technique.

  20. Graphite-moderated and heavy water-moderated spectral shift controlled reactors

    International Nuclear Information System (INIS)

    Alcala Ruiz, F.

    1984-01-01

    It has been studied the physical mechanisms related with the spectral shift control method and their general positive effects on economical and non-proliferant aspects (extension of the fuel cycle length and low proliferation index). This methods has been extended to non-hydrogenous fuel cells of high moderator/fuel ratio: heavy water cells have been con- trolled by graphite rods graphite-moderated and gas-cooled cells have been controlled by berylium rods and graphite-moderated and water-cooled cells have been controlled by a changing mixture of heavy and light water. It has been carried out neutron and thermal analysis on a pre design of these types of fuel cells. We have studied its neutron optimization and their fuel cycles, temperature coefficients and proliferation indices. Finally, we have carried out a comparative analysis of the fuel cycles of conventionally controlled PWRs and graphite-moderated, water-cooled and spectral shift controlled reactors. (Author) 71 refs

  1. Spectral studies of ocean water with space-borne sensor SCIAMACHY using Differential Optical Absorption Spectroscopy (DOAS

    Directory of Open Access Journals (Sweden)

    M. Vountas

    2007-09-01

    Full Text Available Methods enabling the retrieval of oceanic parameter from the space borne instrumentation Scanning Imaging Absorption Spectrometer for Atmospheric ChartographY (SCIAMACHY using Differential Optical Absorption Spectroscopy (DOAS are presented. SCIAMACHY onboard ENVISAT measures back scattered solar radiation at a spectral resolution (0.2 to 1.5 nm. The DOAS method was used for the first time to fit modelled Vibrational Raman Scattering (VRS in liquid water and in situ measured phytoplankton absorption reference spectra to optical depths measured by SCIAMACHY. Spectral structures of VRS and phytoplankton absorption were clearly found in these optical depths. Both fitting approaches lead to consistent results. DOAS fits correlate with estimates of chlorophyll concentrations: low fit factors for VRS retrievals correspond to large chlorophyll concentrations and vice versa; large fit factors for phytoplankton absorption correspond with high chlorophyll concentrations and vice versa. From these results a simple retrieval technique taking advantage of both measurements is shown. First maps of global chlorophyll concentrations were compared to the corresponding MODIS measurements with very promising results. In addition, results from this study will be used to improve atmospheric trace gas DOAS-retrievals from visible wavelengths by including these oceanographic signatures.

  2. Does physical activity moderate the relationship between depression symptomatology and low back pain?

    DEFF Research Database (Denmark)

    Hübscher, Markus; Hartvigsen, Jan; Fernandez, Matthew

    2016-01-01

    PURPOSE: To investigate whether depression symptomatology is associated with low back pain (LBP) in twins aged 70+ and whether this effect depends on a person's physical activity (PA) status. METHODS: This prospective cohort and nested case-control study used a nationally representative sample....... This effect is supposedly not attributable to genetic or shared environmental factors. Physical activity did not moderate the effect of depression symptomatology on LBP....... of twins. Data on depression symptomatology (modified Cambridge Mental Disorders Examination) and self-reported PA were obtained from the Longitudinal Study of Aging Danish Twins using twins without LBP at baseline. Associations between depression symptomatology (highest quartile) at baseline and LBP two...

  3. X-ray absorption spectroscopy: EXAFS and XANES - A versatile tool to study the atomic and electronic structure of materials

    International Nuclear Information System (INIS)

    Alp, E.E.; Mini, S.M.; Ramanathan, M.

    1990-01-01

    X-ray absorption spectroscopy (XAS) had been an essential tool to gather spectroscopic information about atomic energy level structure in the early decades of this century. The correct interpretation of the oscillatory structure in the x-ray absorption cross-section above the absorption edge has transformed XAS from a spectroscopic tool to a structural technique. EXAFS (Extended X-ray Absorption Fine Structure) yields information about the interatomic distances, near neighbor coordination numbers, and lattice dynamics. XANES (X-ray Absorption Near Edge Structure), on the other hand, gives information about the valence state, energy bandwidth and bond angles. Today, there are about 50 experimental stations in various synchrotrons around the world dedicated to collecting x-ray absorption data from the bulk and surfaces of solids and liquids. In this chapter, they will give the basic principles of XAS, explain the information content of essentially two different aspects of the absorption process leading to EXAFS and XANES, and discuss the source and sample limitations

  4. H2O temperature sensor for low-pressure flames using tunable diode laser absorption near 2.9 νm

    KAUST Repository

    Li, Sijie

    2011-10-19

    Making use of a newly available rapid-tuning diode laser operating at wavelengths up to 2.9 νm, an absorption-based temperature sensor was developed for in situ measurements in low-pressure flames. Based on the systematic analysis of H2O vapor transitions in the fundamental vibrational bands (ν1 and ν3) of H2O in the range of 2.5-3.0 νm, an optimal closely-spaced spectral line pair near 2.9 νm was selected for its temperature sensitivity in the range of 1000-2500 K. The narrow-linewidth room-temperature laser was scanned repetitively across these spectral features at 5 kHz, enabling fast, accurate temperature sensing. Use of the temperature sensor was investigated in low-pressure flames supported on a McKenna burner at 15, 25 and 60 Torr. To avoid absorption by the cold gases in the flame edges and the recirculation region between the burner and the vacuum chamber wall, a variable-path in situ probe was designed and an optimal path length was determined to accurately measure the flame centerline temperature. Different flame conditions were investigated to illustrate the potential of this sensor system for sensitive measurements of combustion temperature in low-pressure flames. © 2011 IOP Publishing Ltd.

  5. Low toxicity, absorption, turnover and excretion of copper in the Merino sheep

    Energy Technology Data Exchange (ETDEWEB)

    Neethling, L P; Brown, J M.M.; de Wet, P J

    1968-01-01

    The absorption, storage and excretion of copper has been investigated in Merino sheep following intra-abomasal, intraruminal and intravenous administration of Cu-64. The excretion of the element via bile or urine is strictly limited. There is a most effective mechanism operating in the sheep which limits the intestinal absorption of the element when given in physiological or reasonable pharmacological doses. The absorption is increased to a certain threshold value in animals depleted of copper. In such animals administration of single abnormally large doses of copper does not force more copper through the intestinal mucosa. The ovine sheep liver clears administered copper rapidly from the blood stream and retains it avidly. Excess copper presumably previously loosely bound to albumin is rapidly eliminated by the kidneys. 35 references.

  6. Management of moderate to severe Alzheimer’s disease: Focus on memantine

    Directory of Open Access Journals (Sweden)

    Evangelyn Dominguez

    2011-12-01

    Full Text Available Alzheimer’s disease (AD is the most common form of dementia, and one of the principal causes leading to death around the world. It is a progressive neurodegenerative disorder that still remains without definite cure. Memantine, a licensed AD drug, is an open-channel and partial trapping blocker that functions as a potent NMDA receptor antagonist, even at low concentrations. Aside from being uncompetitive, it also allows near-normal physiological NMDA receptor activity throughout the brain even with high glutamate concentrations, making it more reliable and tolerable than other AD-targeted drugs. It has also been found to be effective, safe, and well-tolerated in animal models as well as patients with moderate-to-severe AD. Aside from NMDA receptor antagonism, numerous studies have reported that memantine can also affect dopamine receptors, block excessive calcium influx and production of reactive oxygen species (ROS induced by Aβ oligomers, and inhibit the internal ribosome entry site (IRES, thus preventing the expression of the amyloid precursor and tau proteins which are considered as early indicators of Alzheimer's.

  7. Converting Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2013-01-01

    are suggested: An optimization method for the surface impedances for locally reacting absorbers, the flow resistivity for extendedly reacting absorbers, and the flow resistance for fabrics. With four porous type absorbers, the conversion methods are validated. For absorbers backed by a rigid wall, the surface...... coefficients to random incidence absorption coefficients are proposed. The overestimations of the Sabine absorption coefficient are investigated theoretically based on Miki's model for porous absorbers backed by a rigid wall or an air cavity, resulting in conversion factors. Additionally, three optimizations...... impedance optimization produces the best results, while the flow resistivity optimization also yields reasonable results. The flow resistivity and flow resistance optimization for extendedly reacting absorbers are also found to be successful. However, the theoretical conversion factors based on Miki's model...

  8. Atomic absorption assessment of mineral iron quantity in ferritin

    International Nuclear Information System (INIS)

    Marinova, M.; Vladimirova, L.

    2009-01-01

    Possibilities for quantitative determination of the number of iron atoms in the mineral core of ferritin by atomic absorption spectroscopy (AAS) are investigated in the work. Different measurements with AAS show an iron content from 1000 up to 4500 atoms per molecule ferritin. This motivated us to investigate the amount of iron in the Horse Spleen Ferritin with atomic absorption spectroscopy under application of the Bulgarian standard BDS EN 14082/2003 Foodstuffs - Determination of trace elements - Determination of lead, cadmium, zinc, copper, iron and chromium by atomic absorption spectrometry (AAS) after dry ashing. The obtained results give approx. 1800 atoms per molecule Ferritin. It is in accordance with previous results, published by leading researchers. The investigation of the iron content with AAS under the use of the Bulgarian standard is a good opportunity to study many other objects of biological interest. (authors)

  9. Low energy neutrons from a sup 2 sup 3 sup 9 PuBe isotopic neutron source inserting in moderating media

    CERN Document Server

    Vega, H R

    2002-01-01

    Several neutron applications share a common problem: the neutron source design. In this work MCNP computer code has been used to design a moderated sup 2 sup 3 sup 9 PuBe neutron source to produce low energy neutrons. The design involves the source located at the center of a spherical moderator. Moderator media studied were light water, heavy water and a heterogeneous combination of light water and heavy water. Similar moderating features were found between the 24.5 cm-radius container filled with heavy water (23.0-cm-thick) and that made with light water (3.5-cm-thick) plus heavy water (19.5-cm-thick). A sup 2 sup 3 sup 9 PuBe neutron source inserted in this moderator produces, at 27 cm, a neutron fluence of 1.8 x 10 sup - sup 4 n-cm sup - sup 2 per source neutron, with an average neutron energy of 0.34 MeV, where 47.8 % have an energy <= 0.4 eV. A further study of this moderator was carried out using a reflector medium made of graphite. Thus, 15-cm-thickness reflector improves the neutron field producing...

  10. Reflection effect of localized absorptive potential on non-resonant and resonant tunneling

    International Nuclear Information System (INIS)

    Rubio, A.; Kumar, N.

    1992-06-01

    The reflection due to absorptive potential (-iV i ) for resonant and non-resonant tunneling has been considered. We show that the effect of reflection leads to a non-monotonic dependence of absorption on the strength V i with a maximum absorption of typically 0.5. This has implications for the operation of resonant tunneling devices. General conceptual aspects of absorptive potentials are discussed. (author). 9 refs, 2 figs

  11. A moderation layer to improve the safety behavior of sodium cooled fast reactors

    International Nuclear Information System (INIS)

    Merk, B.; Weiß, F.P.

    2011-01-01

    The nature of the sodium void effect in an infinite lattice is discussed and for a reduction of the effect the insertion of moderating material is proposed. The effect of three different moderating layers on the sodium void defect and the feedback effects is investigated. Especially the uranium zirconium hydride UzrH layer causes a strong reduction of the sodium void effect. Additionally, this layer improves the fuel temperature effect and the coolant effect of the system significantly. All changes caused by the insertion of the UZrH layer lead to a significant increase in stability of the fast reactor system against transients. The moderating layers have only a small influence on the breeding effect and on the production of minor actinides. (author)

  12. A moderation layer to improve the safety behavior of sodium cooled fast reactors

    Energy Technology Data Exchange (ETDEWEB)

    Merk, B.; Weiß, F.P., E-mail: b.merk@fzd.de [Forschungszentrum Dresden-Rossendorf, Institut für Sicherheitsforschung, Dresden (germany)

    2011-07-01

    The nature of the sodium void effect in an infinite lattice is discussed and for a reduction of the effect the insertion of moderating material is proposed. The effect of three different moderating layers on the sodium void defect and the feedback effects is investigated. Especially the uranium zirconium hydride UzrH layer causes a strong reduction of the sodium void effect. Additionally, this layer improves the fuel temperature effect and the coolant effect of the system significantly. All changes caused by the insertion of the UZrH layer lead to a significant increase in stability of the fast reactor system against transients. The moderating layers have only a small influence on the breeding effect and on the production of minor actinides. (author)

  13. Environmental lead exposure increases micronuclei in children

    DEFF Research Database (Denmark)

    Kapka, Lucyna; Baumgartner, Adolf; Siwińska, Ewa

    2007-01-01

    The objective of this pilot study was to investigate the contribution of environmental exposures to lead in the development of cytogenetic damage detected as the frequency of micronuclei (MN) in children. The other aim was to apply the MN assay in combination with fluorescence in situ hybridization...... age from an unexposed recreational area. Exposure to lead was assessed by determination of lead concentrations in blood (PbB) by atomic absorption spectrophotometry, whereas the level of selenium (Se) in serum was detected by using graphite furnace atomic-absorption spectrometry. The frequency of MN...... was determined by the cytokinesis-block MN assay and fluorescence in situ hybridization performed using a specific pan-centromeric probe. Environmental exposure to lead resulted in significantly increased levels of PbB (5.29 +/- 2.09 versus 3.45 +/- 1.20 microg/dl in controls), although the average level...

  14. Automized squark-neutralino production to next-to-leading order

    International Nuclear Information System (INIS)

    Binoth, Thomas; Wigmore, Ioan; Netto, Dorival Goncalves; Lopez-Val, David; Plehn, Tilman; Mawatari, Kentarou

    2011-01-01

    The production of one hard jet in association with missing transverse energy is a major LHC search channel motivated by many scenarios for physics beyond the standard model. In scenarios with a weakly interacting dark matter candidate, like supersymmetry, it arises from the associated production of a quark partner with the dark matter agent. We present the next-to-leading-order cross section calculation as the first application of the fully automized MadGolem package. We find moderate corrections to the production rate with a strongly reduced theory uncertainty.

  15. Seasonal dynamics of light absorption by chromophoric dissolved organic matter (CDOM) in the NW Mediterranean Sea (BOUSSOLE site)

    Science.gov (United States)

    Organelli, Emanuele; Bricaud, Annick; Antoine, David; Matsuoka, Atsushi

    2014-09-01

    We analyze a two-year time-series of chromophoric dissolved organic matter (CDOM) light absorption measurements in the upper 400 m of the water column at the BOUSSOLE site in the NW Mediterranean Sea. The seasonal dynamics of the CDOM light absorption coefficients at 440 nm (acdom(440)) is essentially characterized by (i) subsurface maxima forming in spring and progressively reinforcing throughout summer, (ii) impoverishment in the surface layer throughout summer and (iii) vertical homogeneity in winter. Seasonal variations of the spectral dependence of CDOM absorption, as described by the exponential slope value (Scdom), are characterized by highest values in summer and autumn at the surface and low values at the depths of acdom(440) subsurface maxima or just below them. Variations of acdom(440) are likely controlled by microbial digestion of phytoplankton cells, which leads to CDOM production, and by photochemical destruction (photobleaching), which leads to CDOM degradation. Photobleaching is also the main driver of Scdom variations. Consistently with previous observations, acdom(440) for a given chlorophyll a concentration is higher than expected from Case I waters bio-optical models. The total non-water light absorption budget shows that surface waters at the BOUSSOLE site are largely dominated by CDOM during all seasons but the algal bloom in March and April. These results improve the knowledge of CDOM absorption dynamics in the Mediterranean Sea, which is scarcely documented. In addition, they open the way to improved algorithms for the retrieval of CDOM absorption from field or satellite radiometric measurements.

  16. Lithium absorption by the rabbit gall-bladder

    DEFF Research Database (Denmark)

    Hansen, C P; Holstein-Rathlou, N H; Skøtt, O

    1991-01-01

    Lithium (Li+) absorption across the low-resistance epithelium of the rabbit gall-bladder was studied in order to elucidate possible routes and mechanisms of Li+ transfer. Li+ at a concentration of 0.4 mM in both mucosal and serosal media did not affect isosmotic mucosa-to-serosa fluid absorption...

  17. Identification of genes required for growth of Escherichia coli MG1655 at moderately low pH

    Directory of Open Access Journals (Sweden)

    Bram Vivijs

    2016-10-01

    Full Text Available The survival of some pathotypes of E. coli in very low pH environments like highly acidic foods and the stomach has been well documented and contributes to their success as foodborne pathogens. In contrast, the ability of E. coli to grow at moderately low pH has received less attention, although this property can be anticipated to be also very important for the safety of mildly acidic foods. Therefore, the objective of this study was to identify cellular functions required for growth of the non-pathogenic strain E. coli MG1655 at low pH. First, the role of the four E. coli amino acid decarboxylase systems, which are the major cellular mechanisms allowing extreme acid survival, was investigated using mutants defective in each of the systems. Only the lysine decarboxylase (CadA was required for low pH growth. Secondly, a screening of 8544 random transposon insertion mutants resulted in the identification of six genes affecting growth in LB broth acidified to pH 4.50 with HCl. Two of the genes, encoding the transcriptional regulator LeuO and the elongation factor P-β-lysine ligase EpmA, can be linked to CadA production. Two other genes, encoding the diadenosine tetraphosphatase ApaH and the tRNA modification GTPase MnmE, have been previously implicated in the bacterial response to stresses other than low pH. A fifth gene encodes the LPS heptosyltransferase WaaC, and its mutant has a deep rough colony phenotype, which has been linked to reduced acid tolerance in earlier work. Finally, tatC encodes a secA-independent protein translocase that exports a few dozen proteins and thus is likely to have a pleiotropic phenotype. For mnmE, apaH, epmA,and waaC, de novo in frame deletion and genetic complementation confirmed their role in low pH growth, and these deletion mutants were also affected in growth in apple juice and tomato juice. However, the mutants were not affected in survival in gastric simulation medium at pH 2.5, indicating that growth at

  18. Predictors and moderators of response to enhanced cognitive behaviour therapy and interpersonal psychotherapy for the treatment of eating disorders.

    Science.gov (United States)

    Cooper, Zafra; Allen, Elizabeth; Bailey-Straebler, Suzanne; Basden, Shawnee; Murphy, Rebecca; O'Connor, Marianne E; Fairburn, Christopher G

    2016-09-01

    Consistent predictors, and more especially moderators, of response to psychological treatments for eating disorders have not been identified. The present exploratory study examined predictors and moderators of outcome in adult patients who took part in a randomised clinical trial comparing two leading treatments for these disorders, enhanced cognitive behavioural therapy (CBT-E) and interpersonal psychotherapy (IPT). Four potentially important findings emerged. Firstly, patients with a longer duration of disorder were less likely to benefit from either treatment. Second, across the two treatments the presence, at baseline, of higher levels of over-evaluation of the importance of shape predicted a less good treatment outcome. Third DSM-IV diagnosis did not predict treatment outcome. Fourth, with the exception of patients with baseline low self-esteem who achieved a better outcome with CBT-E, it was generally not possible to identify a subgroup of patients who would differentially benefit from one or other treatment. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Release of lead from bone in pregnancy and lactation

    International Nuclear Information System (INIS)

    Manton, W.I.; Angle, C.R.; Stanek, K.L.; Kuntzelman, D.; Reese, Y.R.; Kuehnemann, T.J.

    2003-01-01

    Concentrations and isotope ratios of lead in blood, urine, 24-h duplicate diets, and hand wipes were measured for 12 women from the second trimester of pregnancy until at least 8 months after delivery. Six bottle fed and six breast fed their infants. One bottle feeder fell pregnant for a second time, as did a breast feeder, and each was followed semicontinuously for totals of 44 and 54 months, respectively. Bone resorption rather than dietary absorption controls changes in blood lead, but in pregnancy the resorption of trabecular and cortical bone are decoupled. In early pregnancy, only trabecular bone (presumably of low lead content) is resorbed, causing blood leads to fall more than expected from hemodilution alone. In late pregnancy, the sites of resorption move to cortical bone of higher lead content and blood leads rise. In bottle feeders, the cortical bone contribution ceases immediately after delivery, but any tendency for blood leads to fall may be compensated by the effect of hemoconcentration produced by the postpartum loss of plasma volume. In lactation, the whole skeleton undergoes resorption and the blood leads of nursing mothers continue to rise, reaching a maximum 6-8 months after delivery. Blood leads fall from pregnancy to pregnancy, implying that the greatest risk of lead toxicity lies with first pregnancies

  20. Social Support Influences on Substance Abuse Outcomes among Sober Living House Residents with Low and Moderate Psychiatric Severity

    Science.gov (United States)

    Polcin, Douglas L.; Korcha, Rachael

    2017-01-01

    Social support and psychiatric severity are known to influence substance abuse. However, little is known about how their influences vary under different conditions. We aimed to study how different types of social support were associated with substance abuse outcomes among persons with low and moderate psychiatric severity who entered Sober Living…

  1. Emission and absorption of radiation

    International Nuclear Information System (INIS)

    Fetter, S.

    1992-01-01

    A full understanding of fissile-material detection requires a solid knowledge of nuclear physics, especially the emission and absorption of radiation. The purpose of this paper is therefore to give a brief explanation of these processes so that the reader can better understand the assumptions leading to the results in the main text

  2. Resonant ULF absorption in storm time conditions

    Directory of Open Access Journals (Sweden)

    Badin V.I.

    2017-03-01

    Full Text Available The work deals with ULF radar observations of the high-latitude ionosphere. Doppler data from the Norwegian STARE instrument are analyzed for the moderate magnetic storm observed on December 31, 1999 – January 01, 2000. Upon averaging the Doppler signals along radar beams, the spectral power of signals is determined for each beam as a function of frequency ranging from 1 to 10 mHz. Sharp drops (about 10 dB of spectral powers with frequency are found for all radar beams. A variational analysis of spectral powers is carried out by least squares, with power drops being modeled by stepwise profiles constructed of mean spectral powers preceding and succeeding the drops. Using this variational analysis, the frequency of the power drop is determined for each radar beam. Being averaged over all beams, this frequency is 4.8±0.5 mHz. The results obtained are interpreted as resonant absorption of ultra-low-frequency (ULF waves occurring on eigenfrequencies of magnetic field lines over wave propagation from the magnetopause deep into the magnetosphere.

  3. Measurement of the C2H2 destruction kinetics by infrared laser absorption spectroscopy in a pulsed low pressure dc discharge

    International Nuclear Information System (INIS)

    Rousseau, A; Guaitella, O; Gatilova, L; Hannemann, M; Roepcke, J

    2007-01-01

    The kinetics of destruction of C 2 H 2 is investigated in a low pressure pulsed dc discharge in dry air. Tuneable diode laser absorption spectroscopy in the mid-infrared region (1350 cm -1 ) has been used to measure the influence of (i) the pulse duration (ii) the pulse repetition rate and (iii) the pulse current on the C 2 H 2 concentration in situ the discharge tube. First, it is shown that in the plasma region under flow conditions the time averaged concentration of C 2 H 2 depends only on the time averaged discharge current. Second, time resolved measurements have been performed in a closed reactor, i.e. under static conditions. A simple kinetic modelling of the pulsed discharge leads to a good agreement with the experimental results and shows that the oxidation rate of C 2 H 2 is mainly controlled by the time averaged concentration of O atoms. Finally, the influence of porous TiO 2 photocatalyst on the C 2 H 2 oxidation rate is reported

  4. Linear absorptive dielectrics

    Science.gov (United States)

    Tip, A.

    1998-06-01

    Starting from Maxwell's equations for a linear, nonconducting, absorptive, and dispersive medium, characterized by the constitutive equations D(x,t)=ɛ1(x)E(x,t)+∫t-∞dsχ(x,t-s)E(x,s) and H(x,t)=B(x,t), a unitary time evolution and canonical formalism is obtained. Given the complex, coordinate, and frequency-dependent, electric permeability ɛ(x,ω), no further assumptions are made. The procedure leads to a proper definition of band gaps in the periodic case and a new continuity equation for energy flow. An S-matrix formalism for scattering from lossy objects is presented in full detail. A quantized version of the formalism is derived and applied to the generation of Čerenkov and transition radiation as well as atomic decay. The last case suggests a useful generalization of the density of states to the absorptive situation.

  5. Principal Physical and Technical Advantages from the Use of Radiogenic Lead as a Coolant of Power Nuclear Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kulikov, G.G. [International Science and Technology Center (ISTC), Krasnoproletarskaya ulitsa 32-34, Moscow, 127473 (Russian Federation); Shmelev, A.N.; Apse, V.A. [Moscow Engineering Physics Institute (State University), Kashirskoe shosse 31, Moscow, 115409 (Russian Federation); Artisyuk, V.V. [Obninsk State Technical University of Nuclear Power Engineering, Obninsk, Kaluzhskaya reg. 249040 (Russian Federation)

    2009-06-15

    )-fuel could be proliferation-protected at an isotopic level by creating favorable conditions for intense generation of even Pu isotopes. These conditions could be created if radiogenic lead is used as a coolant and graphite - as a structural material and neutron moderator. In this case, transition from hard to softened neutron spectrum results in substantial worsening of {sup 239}Pu neutron capture properties while those of {sup 233}U undergo quite insignificant changes. In addition, Pu proliferation protection at an isotopic level is provided under high rate of secondary fuel breeding (mainly of {sup 233}U) just due to weak neutron absorption by radiogenic lead and graphite. Publications on large deposits of thorium and uranium ores [2-3] show that radiogenic lead mainly consists of {sup 208}Pb (useful isotope with low cross-sections of neutron capture). If necessary, {sup 208}Pb may be extracted from already available tailing stocks of uranium and uranium-thorium ore processing mills as a by-product. So, radiogenic lead as a coolant of power nuclear reactors can improve their operation safety, provide proliferation protection of fissionable materials and intensify fuel breeding. In addition to energy generation, radiogenic lead-cooled reactors could be used for hydrogen production and some other kinds of artificial fuel, for production of high-temperature heat and for effective transmutation of radioactive isotopes with extremely low cross-sections of neutron capture reaction. Radiogenic lead opens new opportunities for improving the neutron physical parameters of nuclear reactors and for widening the areas of their future application. References: 1. A.N. Shmelev, et al. Radiowaste Transmutation in Nuclear Reactors. Proceedings of a Specialist Meeting 'Use of Fast Reactors for Actinide Transmutation', September 22-24, 1992, Obninsk, Russia, IAEATECHDOC- 693, IAEA, March 1993, pp.77-86. 2. Jose Marcus Godoy, et al. Aronne. Application of Inductively Coupled Plasma

  6. Moderate drop in water table increases peatland vulnerability to post-fire regime shift.

    Science.gov (United States)

    Kettridge, N; Turetsky, M R; Sherwood, J H; Thompson, D K; Miller, C A; Benscoter, B W; Flannigan, M D; Wotton, B M; Waddington, J M

    2015-01-27

    Northern and tropical peatlands represent a globally significant carbon reserve accumulated over thousands of years of waterlogged conditions. It is unclear whether moderate drying predicted for northern peatlands will stimulate burning and carbon losses as has occurred in their smaller tropical counterparts where the carbon legacy has been destabilized due to severe drainage and deep peat fires. Capitalizing on a unique long-term experiment, we quantify the post-wildfire recovery of a northern peatland subjected to decadal drainage. We show that the moderate drop in water table position predicted for most northern regions triggers a shift in vegetation composition previously observed within only severely disturbed tropical peatlands. The combined impact of moderate drainage followed by wildfire converted the low productivity, moss-dominated peatland to a non-carbon accumulating shrub-grass ecosystem. This new ecosystem is likely to experience a low intensity, high frequency wildfire regime, which will further deplete the legacy of stored peat carbon.

  7. Low voltage operation of electro-absorption modulator promising for high-definition 3D imaging application using a three step asymmetric coupled quantum well structure

    International Nuclear Information System (INIS)

    Na, Byung Hoon; Ju, Gun Wu; Cho, Yong Chul; Lee, Yong Tak; Choi, Hee Ju; Jeon, Jin Myeong; Lee, Soo Kyung; Park, Yong Hwa; Park, Chang Young

    2015-01-01

    In this paper, we propose a transmission type electro-absorption modulator (EAM) operating at 850 nm having low operating voltage and high absorption change with low insertion loss using a novel three step asymmetric coupled quantum well (3 ACQW) structure which can be used as an optical image shutter for high-definition (HD) three dimensional (3D) imaging. Theoretical calculations show that the exciton red shift of 3 ACQW structure is more than two times larger than that of rectangular quantum well (RQW) structure while maintaining high absorption change. The EAM having coupled cavities with 3 ACQW structure shows a wide spectral bandwidth and high amplitude modulation at a bias voltage of only -8V, which is 41% lower in operating voltage than that of RQW, making the proposed EAM highly attractive as an optical image shutter for HD 3D imaging applications

  8. Moderately nonlinear ultrasound propagation in blood-mimicking fluid.

    Science.gov (United States)

    Kharin, Nikolay A; Vince, D Geoffrey

    2004-04-01

    In medical diagnostic ultrasound (US), higher than-in-water nonlinearity of body fluids and tissue usually does not produce strong nonlinearly distorted waves because of the high absorption. The relative influence of absorption and nonlinearity can be characterized by the Gol'dberg number Gamma. There are two limiting cases in nonlinear acoustics: weak waves (Gamma 1). However, at diagnostic frequencies in tissue and body fluids, the nonlinear effects and effects of absorption more likely are comparable (Gol'dberg number Gamma approximately 1). The aim of this work was to study the nonlinear propagation of a moderately nonlinear US second harmonic signal in a blood-mimicking fluid. Quasilinear solutions to the KZK equation are presented, assuming radiation from a flat and geometrically focused circular Gaussian source. The solutions are expressed in a new simplified closed form and are in very good agreement with those of previous studies measuring and modeling Gaussian beams. The solutions also show good agreement with the measurements of the beams produced by commercially available transducers, even without special Gaussian shading.

  9. Absorption-heat-pump system

    Science.gov (United States)

    Grossman, G.; Perez-Blanco, H.

    1983-06-16

    An improvement in an absorption heat pump cycle is obtained by adding adiabatic absorption and desorption steps to the absorber and desorber of the system. The adiabatic processes make it possible to obtain the highest temperature in the absorber before any heat is removed from it and the lowest temperature in the desorber before heat is added to it, allowing for efficient utilization of the thermodynamic availability of the heat supply stream. The improved system can operate with a larger difference between high and low working fluid concentrations, less circulation losses, and more efficient heat exchange than a conventional system.

  10. Moderate alcohol consumption and waiting time to pregnancy

    DEFF Research Database (Denmark)

    Juhl, Mette; Andersen, Anne-Marie Nybo; Grønbæk, Morten

    2001-01-01

    BACKGROUND: Recent research indicates that even a moderate consumption of alcohol in women trying to become pregnant is associated with longer waiting time to pregnancy. The findings, though, are based upon few observations. METHODS: Self-reported data on alcohol intake and waiting time...... to pregnancy (0-2, 3-5, 6-12 and >12 months) was used for 39 612 pregnant women, recruited to the Danish National Birth Cohort within the first 24 weeks of pregnancy from 1997 to 2000. Main outcome measures were odds ratios (OR) for a prolonged waiting time to pregnancy according to alcohol intake. RESULTS......: In nulliparous women neither moderate nor high alcohol intake was related with longer waiting time to pregnancy compared with a low intake. In parous women, a modest association was seen only among those with an intake of >14 drinks per week (subfecundity OR 1.3; 95% confidence interval 1.0-1.7). Women who...

  11. Production And Characterization Of Tungsten-Based Positron Moderators

    International Nuclear Information System (INIS)

    Lucio, O. G. de; Morales, J. G.; Cruz-Manjarrez, H.

    2011-01-01

    Experiments of interest in Atomic Physics require production of well-defined low-energy positron beams through a moderation process of high-energy positrons, which can be produced by either the use of a radioactive source or by accelerator based pair production process. Tungsten is one of the most commonly used moderator materials because of its reasonable efficiency, high work function and relatively low cost. In this work we present different methods to produce tungsten-based candidate moderators in a variety of shapes. We also present results from characterizing these candidate moderators by ion beam analysis and microscopy techniques.

  12. A randomized comparative trial of two low-dose oral isotretinoin regimens in moderate to severe acne vulgaris

    Science.gov (United States)

    Dhaked, Daulat Ram; Meena, Ram Singh; Maheshwari, Anshul; Agarwal, Uma Shankar; Purohit, Saroj

    2016-01-01

    Background: Oral isotretinoin is highly effective in all forms and grades of acne, even in lower dosages (acne vulgaris. Materials and Methods: A total of 240 patients with moderate to severe acne vulgaris were selected and randomized into two groups and treated with a fixed dose of 20 mg of isotretinoin (Group A - daily and Group B - alternate days) for 24 weeks and followed up for 12 weeks post therapy. Results: A total of 234 patients completed the study. At the end of therapy, decrease in the total acne loads up to 98.99% (Group A) and 97.69% (Group B) was achieved from the baseline (P acne, Group A performed significantly better than Group B until the end of 36 weeks. While in the moderate acne, significant difference in the response between both groups was observed only up to 12 weeks. No serious side effect was observed. Conclusion: Both isotretinoin regimens were well tolerated and found to be an effective treatment for moderate to severe acne vulgaris. However, in moderate acne 20 mg alternate day regimen may be preferred. A 20 mg daily regimen is a better choice for severe acne in terms of response. Limitation: Small sample size and short follow-up period. PMID:27730033

  13. Microwave absorption in the singlet paramagnet HoVO4 in high pulsed magnetic fields up to 40 T

    International Nuclear Information System (INIS)

    Goiran, M.; Klingeler, R.; Kazei, Z.A.; Snegirev, V.V.

    2007-01-01

    Microwave absorption of the rare-earth (RE) oxide compound HoVO 4 (tetragonal-zircon structure) is investigated in pulsed magnetic fields up to 40 T in the low-temperature range. For a magnetic field along the tetragonal crystal axis a few resonance absorption lines are observed at the wavelengths 871, 406 and 305 μm corresponding to electron transitions from the ground and low-lying energy levels of the Ho 3+ ion. In addition, broad non-resonance absorption is observed at 871 and 406 μm in fields up to 15 T. The positions and intensities of the observed resonance lines are described quite well within the crystal field formalism with the known crystal field parameters. The effects of the small orthorhombic component of the crystal field, magnetic field misorientation out the symmetry axis and various pair interactions on the absorption spectra in HoVO 4 are analyzed and discussed

  14. Biomarkers of genotoxicity of urban air pollution. Overview and descriptive data from a molecular epidemiology study on populations exposed to moderate-to-low levels of polycyclic aromatic hydrocarbons: the AULIS project

    DEFF Research Database (Denmark)

    Kyrtopoulos, S.A.; Georgiadis, P.; Autrup, H.

    2001-01-01

    in the context of the European Union Environment and Climate Programme, known by the short name of AULIS project, is discussed and descriptive statistics of the main findings of the project are presented. These findings indicate that for cohorts suffering moderate-to-low exposures to airborne particulate...

  15. Studies on absorption of EC waves in assisted startup experiment on FTU

    Science.gov (United States)

    Granucci, G.; Ricci, D.; Farina, D.; Figini, L.; Iraji, D.; Tudisco, O.; Ramponi, G.; Bin, W.

    2012-09-01

    Assistance of EC wave for plasma breakdown and current ramp up is the proposed scenario for the ITER case, characterized by low toroidal electric field. The experimental results on many tokamaks clearly indicate the capabilities of the proposed scheme to have a robust breakdown in ITER. The key aspect of this technique is the EC power required, strongly related to the absorption of the wave in the initial stage of plasma formation. This aspect is generally neglected due to the diagnostics difficulties in the plasma formation phase. As a consequence a multi-pass absorption scheme is usually considered reasonable, leading to a strong absorption after many reflections on the walls. The present study exploits the high temporal and spatial resolution of the fast scanning interferometer of FTU together with the measure of residual power obtained by a sniffer probe. The absorbed EC power is calculated considering also the polarization rotation and the subsequent mode conversion after incidence on the internal wall and compared with that derived from experimental data. The resulting EC power distribution can explain differences observed between perpendicular and oblique injection results, indicating future investigations to define ITER power requirements.

  16. Studies on absorption of EC waves in assisted startup experiment on FTU

    Directory of Open Access Journals (Sweden)

    Ramponi G.

    2012-09-01

    Full Text Available Assistance of EC wave for plasma breakdown and current ramp up is the proposed scenario for the ITER case, characterized by low toroidal electric field. The experimental results on many tokamaks clearly indicate the capabilities of the proposed scheme to have a robust breakdown in ITER. The key aspect of this technique is the EC power required, strongly related to the absorption of the wave in the initial stage of plasma formation. This aspect is generally neglected due to the diagnostics difficulties in the plasma formation phase. As a consequence a multi-pass absorption scheme is usually considered reasonable, leading to a strong absorption after many reflections on the walls. The present study exploits the high temporal and spatial resolution of the fast scanning interferometer of FTU together with the measure of residual power obtained by a sniffer probe. The absorbed EC power is calculated considering also the polarization rotation and the subsequent mode conversion after incidence on the internal wall and compared with that derived from experimental data. The resulting EC power distribution can explain differences observed between perpendicular and oblique injection results, indicating future investigations to define ITER power requirements.

  17. Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2014-01-01

    into random incidence absorption coefficients for porous absorbers are investigated. Two optimization-based conversion methods are suggested: the surface impedance estimation for locally reacting absorbers and the flow resistivity estimation for extendedly reacting absorbers. The suggested conversion methods...

  18. Overview moderator material for nuclear reactor components

    International Nuclear Information System (INIS)

    Mairing Manutu Pongtuluran; Hendra Prihatnadi

    2009-01-01

    In order for a reactor design is considered acceptable absolute technical requirement is fulfilled because the most important part of a reactor design. Safety considerations emphasis on the handling of radioactive substances emitted during the operation of a reactor and radioactive waste handling. Moderator material is a layer that interacts directly with neutrons split the nuclear fuel that will lead to changes in physical properties, nuclear properties, mechanical properties and chemical properties. Reviews moderator of this time is of the types of moderator is often used to meet the requirements as nuclear material. (author)

  19. The EGG 57-CO B-12 absorption test, in the evaluation of patients with low serum B-12

    International Nuclear Information System (INIS)

    Sinow, R.M.; Carmel, R.; Siegel, M.E.

    1985-01-01

    The Schilling Test (ST) is the standard test for diagnosing vitamin B-12 malabsorption (MA). However, patients with subtle gastric dysfunction may have normal ST, but impaired absorption of B-12 given with food. The authors have adapted an Egg B-12 Absorption Test (EBAT) in which 57-Co cyanocobalamin (57-Co B-12) is mixed with scrambled egg to evaluate this phenomenon in patients with low serum B-12, normal ST and possible subtle MA. Lyophilized egg yolk is reconstituted and mixed with 57-Co- B-12 of equal dose to that of ST. The authors studied 46 individuals: 13 controls, 5 patients with known pernicious anemia (PA), in addition to 28 patients with low serum B-12 levels and normal ST. ST/EBAT ratios were calculated. Twenty-eight test patients excreted 13.3% on ST and 3.5% on EBAT. Mean ST/EBAT ratio was 8.2 (1.4-35.9). Five had EBAT results in the PA range (<1%) and ST/EBAT ratios (14.4-35.9) that were significantly elevated. This group is also evaluated with pepsinogen I/II ratios, gastric analysis, deoxyuridine suppression tests, anti intrinsic factor, and antiparietal cell antibodies. The authors' results indicate that the EBAT can differentiate between PA and non PA patients, and that some patients with low serum B-12 levels and normal ST may, in fact, have subtle MA. The EBAT, combined with ST/EBAT ratio, may provide a means for identifying this group of patients

  20. Determination of arsenic, antimony, bismuth, cadmium, copper, lead, molybdenum, silver and zinc in geological materials by atomic-absorption spectrometry

    Science.gov (United States)

    Viets, J.G.; O'Leary, R. M.; Clark, Robert J.

    1984-01-01

    Arsenic, antimony, bismuth, cadmium, copper, lead, molybdenum, silver and zinc are very useful elements in geochemical exploration. In the proposed method, geological samples are fused with potassium pyrosulphate and the fusate is dissolved in a solution of hydrochloric acid, ascorbic acid and potassium iodide. When this solution is shaken with a 10% V/V Aliquat 336 - isobutyl methyl ketone organic phase, the nine elements of interest are selectively partitioned in the organic phase. All nine elements can then be determined in the organic phase using flame atomic-absorption spectrometry. The method is rapid and allows the determination of Ag and Cd at levels down to 0.1 p.p.m., Cu, Mo, and Zn down to 0.5 p.p.m., Pb, Bi and Sb down to 1 p.p.m. and As down to 5 p.p.m. in geological materials.

  1. Extension to Low Energies (<7keV) of High Pressure X-Ray Absorption Spectroscopy

    International Nuclear Information System (INIS)

    Itie, J.-P.; Flank, A.-M.; Lagarde, P.; Idir, M.; Polian, A.; Couzinet, B.

    2007-01-01

    High pressure x-ray absorption has been performed down to 3.6 keV, thanks to the new LUCIA beamline (SLS, PSI) and to the use of perforated diamonds or Be gasket. Various experimental geometries are proposed, depending on the energy of the edge and on the concentration of the studied element. A few examples will be presented: BaTiO3 at the titanium K edge, Zn0.95 Mn0.05O at the manganese K edge, KCl at the potassium K edge

  2. Low dose influenza virus challenge in the ferret leads to increased virus shedding and greater sensitivity to oseltamivir.

    Science.gov (United States)

    Marriott, Anthony C; Dove, Brian K; Whittaker, Catherine J; Bruce, Christine; Ryan, Kathryn A; Bean, Thomas J; Rayner, Emma; Pearson, Geoff; Taylor, Irene; Dowall, Stuart; Plank, Jenna; Newman, Edmund; Barclay, Wendy S; Dimmock, Nigel J; Easton, Andrew J; Hallis, Bassam; Silman, Nigel J; Carroll, Miles W

    2014-01-01

    Ferrets are widely used to study human influenza virus infection. Their airway physiology and cell receptor distribution makes them ideal for the analysis of pathogenesis and virus transmission, and for testing the efficacy of anti-influenza interventions and vaccines. The 2009 pandemic influenza virus (H1N1pdm09) induces mild to moderate respiratory disease in infected ferrets, following inoculation with 106 plaque-forming units (pfu) of virus. We have demonstrated that reducing the challenge dose to 102 pfu delays the onset of clinical signs by 1 day, and results in a modest reduction in clinical signs, and a less rapid nasal cavity innate immune response. There was also a delay in virus production in the upper respiratory tract, this was up to 9-fold greater and virus shedding was prolonged. Progression of infection to the lower respiratory tract was not noticeably delayed by the reduction in virus challenge. A dose of 104 pfu gave an infection that was intermediate between those of the 106 pfu and 102 pfu doses. To address the hypothesis that using a more authentic low challenge dose would facilitate a more sensitive model for antiviral efficacy, we used the well-known neuraminidase inhibitor, oseltamivir. Oseltamivir-treated and untreated ferrets were challenged with high (106 pfu) and low (102 pfu) doses of influenza H1N1pdm09 virus. The low dose treated ferrets showed significant delays in innate immune response and virus shedding, delayed onset of pathological changes in the nasal cavity, and reduced pathological changes and viral RNA load in the lung, relative to untreated ferrets. Importantly, these observations were not seen in treated animals when the high dose challenge was used. In summary, low dose challenge gives a disease that more closely parallels the disease parameters of human influenza infection, and provides an improved pre-clinical model for the assessment of influenza therapeutics, and potentially, influenza vaccines.

  3. Low dose influenza virus challenge in the ferret leads to increased virus shedding and greater sensitivity to oseltamivir.

    Directory of Open Access Journals (Sweden)

    Anthony C Marriott

    Full Text Available Ferrets are widely used to study human influenza virus infection. Their airway physiology and cell receptor distribution makes them ideal for the analysis of pathogenesis and virus transmission, and for testing the efficacy of anti-influenza interventions and vaccines. The 2009 pandemic influenza virus (H1N1pdm09 induces mild to moderate respiratory disease in infected ferrets, following inoculation with 106 plaque-forming units (pfu of virus. We have demonstrated that reducing the challenge dose to 102 pfu delays the onset of clinical signs by 1 day, and results in a modest reduction in clinical signs, and a less rapid nasal cavity innate immune response. There was also a delay in virus production in the upper respiratory tract, this was up to 9-fold greater and virus shedding was prolonged. Progression of infection to the lower respiratory tract was not noticeably delayed by the reduction in virus challenge. A dose of 104 pfu gave an infection that was intermediate between those of the 106 pfu and 102 pfu doses. To address the hypothesis that using a more authentic low challenge dose would facilitate a more sensitive model for antiviral efficacy, we used the well-known neuraminidase inhibitor, oseltamivir. Oseltamivir-treated and untreated ferrets were challenged with high (106 pfu and low (102 pfu doses of influenza H1N1pdm09 virus. The low dose treated ferrets showed significant delays in innate immune response and virus shedding, delayed onset of pathological changes in the nasal cavity, and reduced pathological changes and viral RNA load in the lung, relative to untreated ferrets. Importantly, these observations were not seen in treated animals when the high dose challenge was used. In summary, low dose challenge gives a disease that more closely parallels the disease parameters of human influenza infection, and provides an improved pre-clinical model for the assessment of influenza therapeutics, and potentially, influenza vaccines.

  4. Electronic and optical properties of lead iodide

    DEFF Research Database (Denmark)

    Ahuja, R.; Arwin, H.; Ferreira da Silva, A.

    2002-01-01

    The electronic properties and the optical absorption of lead iodide (PbI2) have been investigated experimentally by means of optical absorption and spectroscopic ellipsometry, and theoretically by a full-potential linear muffin-tin-orbital method. PbI2 has been recognized as a very promising...

  5. Sub-band-gap absorption in Ga2O3

    Science.gov (United States)

    Peelaers, Hartwin; Van de Walle, Chris G.

    2017-10-01

    β-Ga2O3 is a transparent conducting oxide that, due to its large bandgap of 4.8 eV, exhibits transparency into the UV. However, the free carriers that enable the conductivity can absorb light. We study the effect of free carriers on the properties of Ga2O3 using hybrid density functional theory. The presence of free carriers leads to sub-band-gap absorption and a Burstein-Moss shift in the onset of absorption. We find that for a concentration of 1020 carriers, the Fermi level is located 0.23 eV above the conduction-band minimum. This leads to an increase in the electron effective mass from 0.27-0.28 me to 0.35-0.37 me and a sub-band-gap absorption band with a peak value of 0.6 × 103 cm-1 at 3.37 eV for light polarized along the x or z direction. Both across-the-gap and free-carrier absorption depend strongly on the polarization of the incoming light. We also provide parametrizations of the conduction-band shape and the effective mass as a function of the Fermi level.

  6. Numerical study of surface plasmon enhanced nonlinear absorption and refraction.

    Science.gov (United States)

    Kohlgraf-Owens, Dana C; Kik, Pieter G

    2008-07-07

    Maxwell Garnett effective medium theory is used to study the influence of silver nanoparticle induced field enhancement on the nonlinear response of a Kerr-type nonlinear host. We show that the composite nonlinear absorption coefficient, beta(c), can be enhanced relative to the host nonlinear absorption coefficient near the surface plasmon resonance of silver nanoparticles. This enhancement is not due to a resonant enhancement of the host nonlinear absorption, but rather due to a phase shifted enhancement of the host nonlinear refractive response. The enhancement occurs at the expense of introducing linear absorption, alpha(c), which leads to an overall reduced figure of merit beta(c)/alpha(c) for nonlinear absorption. For thin (< 1 microm) composites, the use of surface plasmons is found to result in an increased nonlinear absorption response compared to that of the host material.

  7. Exercise, Insulin Absorption Rates, and Artificial Pancreas Control

    Science.gov (United States)

    Frank, Spencer; Hinshaw, Ling; Basu, Rita; Basu, Ananda; Szeri, Andrew J.

    2016-11-01

    Type 1 Diabetes is characterized by an inability of a person to endogenously produce the hormone insulin. Because of this, insulin must be injected - usually subcutaneously. The size of the injected dose and the rate at which the dose reaches the circulatory system have a profound effect on the ability to control glucose excursions, and therefore control of diabetes. However, insulin absorption rates via subcutaneous injection are variable and depend on a number of factors including tissue perfusion, physical activity (vasodilation, increased capillary throughput), and other tissue geometric and physical properties. Exercise may also have a sizeable effect on the rate of insulin absorption, which can potentially lead to dangerous glucose levels. Insulin-dosing algorithms, as implemented in an artificial pancreas controller, should account accurately for absorption rate variability and exercise effects on insulin absorption. The aforementioned factors affecting insulin absorption will be discussed within the context of both fluid mechanics and data driven modeling approaches.

  8. Comparing the Efficacy of Low Dose and Conventional Dose of Oral Isotretinoin in Treatment of Moderate and Severe Acne Vulgaris.

    Science.gov (United States)

    Faghihi, Gita; Mokhtari, Fatemeh; Fard, Nasrin Motamedi; Motamedi, Narges; Hosseini, Sayed Mohsen

    2017-01-01

    This study was conducted to compare the effect of low-dose isotretinoin with its conventional dose in patients with moderate and severe acne. This was a clinical trial conducted on 60 male and female patients with moderate and severe acne vulgaris. The patients were divided into two treatment groups: 0.5 mg/kg/day isotretinoin capsule and low-dose isotretinoin capsule (0.25 mg/kg/day). Patients in both groups received 6-month treatment. At the end of the 6 th month and 12 th month (6 months after the end of the treatment), they were examined again, and their improvement was determined and compared. The average severity of acne in the two treatment groups did not differ significantly within any of the study periods. The most common side effects were nose dryness in the low-dose group (17%) and hair thinning and loss in the conventional-dose group (33.2%), although all the patients had dry lips. According to the same severity of the acne in two groups in different study periods, as well as fewer side effects and more patients' satisfaction, the low-dose isotretinoin can be considered in the treatment of acne.

  9. Efficacy of low to moderate doses of oxcarbazepine in adult patients with newly diagnosed partial epilepsy.

    Science.gov (United States)

    Zou, Xue-Mei; Chen, Jia-Ni; An, Dong-Mei; Hao, Nan-Ya; Hong, Zhen; Hao, Xiao-Ting; Rao, Ping; Zhou, Dong

    2015-07-01

    The objective of this study was to explore the efficacy of low dose of oxcarbazepine (OXC) in adult patients with newly diagnosed partial epilepsy in an actual clinical setting. The associated factors influencing the poor control of seizures were also evaluated. The epilepsy database (2010-2014) from the Epilepsy Clinic of West China Hospital was retrospectively reviewed. A total of 102 adult patients with newly diagnosed, previously untreated partial epilepsy initially treated with OXC were included, and divided into good response group (64) and poor response group (38) according to whether they were seizure-free for at least 12 months. There were 27 (26.5%) patients becoming seizure-free with OXC 600 mg/day monotherapy. The remaining 75 patients had doses of either increasing OXC to 900 mg/day (n = 59) or the addition of another antiepileptic drug (AED) (n = 16), with another 20 (19.6%) and six (5.9%) patients becoming seizure-free, respectively (P = 0.788). In addition, two (2.0%) and nine (8.8%) patients became seizure-free with OXC > 900 mg/day monotherapy and OXC ≥ 900 mg/day combination therapy, respectively. Multivariate binary logistic regression analysis revealed that the time from onset of epilepsy to treatment initiation is significantly associated with seizure control (P = 0.02). Our results indicated that OXC at low to moderate doses is effective for the treatment of Chinese adult patients with newly diagnosed, previously untreated partial epilepsy, and a longer time interval from the onset of epilepsy to the start of treatment significantly predicts poor seizure control. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  10. A novel solar energy integrated low-rank coal fired power generation using coal pre-drying and an absorption heat pump

    International Nuclear Information System (INIS)

    Xu, Cheng; Bai, Pu; Xin, Tuantuan; Hu, Yue; Xu, Gang; Yang, Yongping

    2017-01-01

    Highlights: •An improved solar energy integrated LRC fired power generation is proposed. •High efficient and economic feasible solar energy conversion is achieved. •Cold-end losses of the boiler and condenser are reduced. •The energy and exergy efficiencies of the overall system are improved. -- Abstract: A novel solar energy integrated low-rank coal (LRC) fired power generation using coal pre-drying and an absorption heat pump (AHP) was proposed. The proposed integrated system efficiently utilizes the solar energy collected from the parabolic trough to drive the AHP to absorb the low-grade waste heat of the steam cycle, achieving larger amount of heat with suitable temperature for coal’s moisture removal prior to the furnace. Through employing the proposed system, the solar energy could be partially converted into the high-grade coal’s heating value and the cold-end losses of the boiler and the steam cycle could be reduced simultaneously, leading to a high-efficient solar energy conversion together with a preferable overall thermal efficiency of the power generation. The results of the detailed thermodynamic and economic analyses showed that, using the proposed integrated concept in a typical 600 MW LRC-fired power plant could reduce the raw coal consumption by 4.6 kg/s with overall energy and exergy efficiencies improvement of 1.2 and 1.8 percentage points, respectively, as 73.0 MW th solar thermal energy was introduced. The cost of the solar generated electric power could be as low as $0.044/kW h. This work provides an improved concept to further advance the solar energy conversion and utilisation in solar-hybrid coal-fired power generation.

  11. Effect of various absorption enhancers based on tight junctions on the intestinal absorption of forsythoside A in Shuang-Huang-Lian, application to its antivirus activity.

    Science.gov (United States)

    Zhou, Wei; Zhu, Xuan Xuan; Yin, Ai Ling; Cai, Bao Chang; Wang, Hai Dan; Di, Liuqing; Shan, Jin Jun

    2014-01-01

    Forsythoside A (FTA), one of the main active ingredients in Shuang-Huang-Lian (SHL), possesses strong antibacterial, antioxidant and antiviral effects, and its pharmacological effects was higher than that of other ingredients, but the absolute bioavailability orally was approximately 0.72%, which was significantly low, influencing clinical efficacies of its oral preparations seriously. In vitro Caco-2 cell and in vivo pharmacokinetics study were simultaneously performed to investigate the effects of absorption enhancers based on tight junctions: sodium caprate and water-soluble chitosan on the intestinal absorption of FTA, and the eventual mucosal epithelial damage resulted from absorption enhancers was evaluated by MTT test and morphology observation, respectively. The pharmacological effects such as antivirus activity improvement by absorption enhancers were verified by MDCK damage inhibition rate after influenza virus propagation. The observations from in vitro Caco-2 cell showed that the absorption of FTA in SHL could be improved by absorption enhancers. Meanwhile, the absorption enhancing effect of water-soluble chitosan may be almost saturable up to 0.0032% (w/v), and sodium caprate at concentrations up to 0.64 mg/mL was safe, but water-soluble chitosan at different concentrations was all safe for these cells. In pharmacokinetics study, water-soluble chitosan at dosage of 50 mg/kg improved the bioavailability of FTA in SHL to the greatest extent, and was safe for gastrointestine from morphological observation. Besides, treatment with SHL with water-soluble chitosan at dosage of 50 mg/kg prevented MDCK damage after influenza virus propagation better significantly than that of control. Water-soluble chitosan at dosage of 50 mg/kg might be safe and effective absorption enhancer for improving the bioavailability of FTA and the antivirus activity in vitro in SHL.

  12. Criticality of moderated and undermoderated low-enriched uranium oxide systems

    International Nuclear Information System (INIS)

    Goebel, G.R.

    1980-06-01

    Uranium oxide was enriched to 4.46 wt % 235 U compacted to a density of 4.68 g/cm 3 . The uranium oxide was packed into cubical aluminum cans and water added to the oxide until an H/U atomic ratio of 0.77 was achieved. A 5 x 5 x 5 array of uranium oxide cans for the experiments were used when no plastic moderator material was placed between cans. High enriched uranium drivers were used to achieve criticality. Criticality was achieved for smaller arrays without a driver when 24.5 mm plastic moderator material was placed between the cans. Twelve critical experiments are reported, six in each reflector

  13. THE INTRINSIC FRACTIONS AND RADIO PROPERTIES OF LOW-IONIZATION BROAD ABSORPTION LINE QUASARS

    International Nuclear Information System (INIS)

    Dai Xinyu; Shankar, Francesco; Sivakoff, Gregory R.

    2012-01-01

    Low-ionization (Mg II, Fe II, and Fe III) broad absorption line quasars (LoBALs) probe a relatively obscured quasar population and could be at an early evolutionary stage for quasars. We study the intrinsic fractions of LoBALs using the Sloan Digital Sky Survey (SDSS), Two Micron All Sky Survey, and Faint Images of the Radio Sky at Twenty cm survey. We find that the LoBAL fractions of the near-infrared (NIR) and radio samples are approximately 5-7 times higher than those measured in the optical sample. This suggests that the fractions measured in the NIR and radio bands are closer to the intrinsic fractions of the populations, and that the optical fractions are significantly biased due to obscuration effects, similar to high-ionization broad absorption line quasars (HiBALs). Considering a population of obscured quasars that do not enter the SDSS, which could have a much higher LoBAL fraction, we expect that the intrinsic fraction of LoBALs could be even higher. We also find that the LoBAL fractions decrease with increasing radio luminosities, again, similarly to HiBALs. In addition, we find evidence for increasing fractions of LoBALs toward higher NIR luminosities, especially for FeLoBALs with a fraction of ∼18% at M K s < -31 mag. This population of NIR-luminous LoBALs may be at an early evolutionary stage of quasar evolution. To interpret the data, we use a luminosity-dependent model for LoBALs that yields significantly better fits than those from a pure geometric model.

  14. Credibility judgments of narratives: language, plausibility, and absorption.

    Science.gov (United States)

    Nahari, Galit; Glicksohn, Joseph; Nachson, Israel

    2010-01-01

    Two experiments were conducted in order to find out whether textual features of narratives differentially affect credibility judgments made by judges having different levels of absorption (a disposition associated with rich visual imagination). Participants in both experiments were exposed to a textual narrative and requested to judge whether the narrator actually experienced the event he described in his story. In Experiment 1, the narrative varied in terms of language (literal, figurative) and plausibility (ordinary, anomalous). In Experiment 2, the narrative varied in terms of language only. The participants' perceptions of the plausibility of the story described and the extent to which they were absorbed in reading were measured. The data from both experiments together suggest that the groups applied entirely different criteria in credibility judgments. For high-absorption individuals, their credibility judgment depends on the degree to which the text can be assimilated into their own vivid imagination, whereas for low-absorption individuals it depends mainly on plausibility. That is, high-absorption individuals applied an experiential mental set while judging the credibility of the narrator, whereas low-absorption individuals applied an instrumental mental set. Possible cognitive mechanisms and implications for credibility judgments are discussed.

  15. Evil genius? How dishonesty can lead to greater creativity.

    Science.gov (United States)

    Gino, Francesca; Wiltermuth, Scott S

    2014-04-01

    We propose that dishonest and creative behavior have something in common: They both involve breaking rules. Because of this shared feature, creativity may lead to dishonesty (as shown in prior work), and dishonesty may lead to creativity (the hypothesis we tested in this research). In five experiments, participants had the opportunity to behave dishonestly by overreporting their performance on various tasks. They then completed one or more tasks designed to measure creativity. Those who cheated were subsequently more creative than noncheaters, even when we accounted for individual differences in their creative ability (Experiment 1). Using random assignment, we confirmed that acting dishonestly leads to greater creativity in subsequent tasks (Experiments 2 and 3). The link between dishonesty and creativity is explained by a heightened feeling of being unconstrained by rules, as indicated by both mediation (Experiment 4) and moderation (Experiment 5).

  16. Solar and Interplanetary Disturbances causing Moderate ...

    Indian Academy of Sciences (India)

    magnetospheric conditions leading to 121 moderate geomagnetic storms. (MGS) have been ... increases on sudden storm commencement (SSC) day than its previous day value and acquires .... Tokyo, Japan. Webb, D. F. 1995, Rev. Geophys.

  17. Upgrades to the ISIS moderator configuration

    International Nuclear Information System (INIS)

    Taylor, A.D.

    1989-01-01

    The current ISIS moderator configuration, was designed in 1980 to provide a flexible set of beams for a hypothetical instrument suite. The use of fluid moderators at three different temperatures offering six faces to the instruments, has proved to be effective. In this paper we discuss an upgrade of these moderators in the light of the current and projected instrument configuration. (author)

  18. Extending supplementary feeding for children younger than 5 years with moderate acute malnutrition leads to lower relapse rates

    Science.gov (United States)

    Children with moderate acute malnutrition (MAM) have a high rate of relapse and death in the year following recovery. In this pilot study, we evaluate the long-term benefits of an extended course of nutritional therapy for children with MAM. Rural Malawian children 6 to 59 months old with MAM, defin...

  19. Absorption dips at low x-ray energies in Cygnus X-1

    International Nuclear Information System (INIS)

    Murdin, P.

    1976-01-01

    Three more looks with the Copernicus satellite at Cygnus X-1 have produced four more examples of absorption dips, decreases in the 2 to 7 keV flux from Cygnus X-1 with an increase of spectral hardness consistent with photoelectric absorption (Mason et al 1974). The nine now seen, including one by OSO-7 (Li and Clark 1974), are listed in Table 1. Their phase in the spectroscopic binary HD 226868 is also listed, calculated from a newer ephemeris than that in Mason et al (1974), adding the radial velocities by Bolton (1975) and unpublished RGO radial velocities from the 1975 season. (These elements do not differ significantly from Bolton's

  20. Moderator temperature coefficient in BWR core

    International Nuclear Information System (INIS)

    Naito, Yoshitaka

    1977-01-01

    Temperature dependences of infinite multiplication factor k sub(infinity) and neutron leakage from the core must be examined for estimation of moderator temperature coefficient. Temperature dependence on k sub(infinity) has been investigated by many researchers, however, the dependence on neutron leakage of a BWR with cruciformed control rods has hardly been done. Because there are difficulties and necessity on calculations of three space dimensional and multi-energy groups neutron distribution in a BWR core. In this study, moderator temperature coefficients of JPDR-II (BWR) core were obtained by calculation with DIFFUSION-ACE, which is newly developed three-dimensional multi-group computer code. The results were compared with experimental data measured from 20 to 275 0 C of the moderator temperature and the good agreement was obtained between calculation and measurement. In order to evaluate neutron leakage from the core, the other two calculations were carried out, adjusting criticality by uniform absorption rate and by material buckling. The former underestimated neutron leakage and the latter overestimated it. Discussion on the results shows that in order to estimate the temperature coefficient of BWR, neutron leakage must be evaluated precisely, therefore the calculation at actual pattern of control rods is necessary. (auth.)

  1. Performance and exposure indices of rats exposed to low concentrations of lead.

    Science.gov (United States)

    Cory-Slechta, D A; Weiss, B; Cox, C

    1985-04-01

    To further characterize the lower end of the function relating lead exposure and biological exposure indices to behavior, male weanling rats were exposed chronically to drinking solutions containing 25 ppm sodium acetate (controls) or 25 ppm lead acetate. Behavioral training began when the animals reached 50 days of age, and performance on a fixed-interval 1-min schedule of food reinforcement was then assessed over 90 experimental sessions (136 days). This exposure produced overall response rate increases over the first 40 sessions that were similar to those observed previously with higher concentrations of lead. Response rates of the two groups tended to merge subsequently. The increased overall response rates in the treated group derived primarily from an increased frequency of shorter interresponse times (IRTs) and increased running rates (calculated without the postreinforcement interval). Blood lead (PbB) and zinc protoporphyrin (ZPP) values were determined following sessions 30, 60, and 90. PbB values of the lead-exposed group averaged 15 to 20 micrograms/dl throughout the study; ZPP did not differ. The mean brain lead value of the treated group was 0.07 micrograms Pb/g. Blood-brain ratios (1.38 to 4.06) were substantially greater than those previously observed at higher exposures. These data extend to even lower exposures, and lower blood lead concentrations, the effective concentration for behavioral effects, and further emphasize the importance of the sensitivity of the endpoint in assessing behavioral toxicity.

  2. Moderate resolution spectrophotometry of high redshift quasars

    Science.gov (United States)

    Schneider, Donald P.; Schmidt, Maarten; Gunn, James E.

    1991-01-01

    A uniform set of photometry and high signal-to-noise moderate resolution spectroscopy of 33 quasars with redshifts larger than 3.1 is presented. The sample consists of 17 newly discovered quasars (two with redshifts in excess of 4.4) and 16 sources drawn from the literature. The objects in this sample have r magnitudes between 17.4 and 21.4; their luminosities range from -28.8 to -24.9. Three of the 33 objects are broad absorption line quasars. A number of possible high redshift damped Ly-alpha systems were found.

  3. A Green Preconcentration Method for Determination of Cobalt and Lead in Fresh Surface and Waste Water Samples Prior to Flame Atomic Absorption Spectrometry

    Directory of Open Access Journals (Sweden)

    Naeemullah

    2012-01-01

    Full Text Available Cloud point extraction (CPE has been used for the preconcentration and simultaneous determination of cobalt (Co and lead (Pb in fresh and wastewater samples. The extraction of analytes from aqueous samples was performed in the presence of 8-hydroxyquinoline (oxine as a chelating agent and Triton X-114 as a nonionic surfactant. Experiments were conducted to assess the effect of different chemical variables such as pH, amounts of reagents (oxine and Triton X-114, temperature, incubation time, and sample volume. After phase separation, based on the cloud point, the surfactant-rich phase was diluted with acidic ethanol prior to its analysis by the flame atomic absorption spectrometry (FAAS. The enhancement factors 70 and 50 with detection limits of 0.26 μg L−1 and 0.44 μg L−1 were obtained for Co and Pb, respectively. In order to validate the developed method, a certified reference material (SRM 1643e was analyzed and the determined values obtained were in a good agreement with the certified values. The proposed method was applied successfully to the determination of Co and Pb in a fresh surface and waste water sample.

  4. Antimony orthophosphate glasses with large nonlinear refractive indices, low two-photon absorption coefficients, and ultrafast response

    International Nuclear Information System (INIS)

    Falcao-Filho, E.L.; Araujo, Cid B. de; Bosco, C.A.C.; Maciel, G.S.; Acioli, L.H.; Nalin, M.; Messaddeq, Y.

    2005-01-01

    Antimony glasses based on the composition Sb 2 O 3 -SbPO 4 were prepared and characterized. The samples present high refractive index, good transmission from 380 to 2000 nm, and high thermal stability. The nonlinear refractive index, n 2 , of the samples was studied using the optical Kerr shutter technique at 800 nm. The third-order correlation signals between pump and probe pulses indicate ultrafast response ( 2 was observed by adding lead oxide to the Sb 2 O 3 -SbPO 4 composition. Large values of n 2 ≅10 -14 cm 2 /W and negligible two-photon absorption coefficients (smaller than 0.01 cm/GW) were determined for all samples. The glass compositions studied present appropriate figure-of-merit for all-optical switching applications

  5. Influence of minerals on lead-induced alterations in liver function in rats exposed to long-term lead exposure

    International Nuclear Information System (INIS)

    Herman, D'souza Sunil; Geraldine, Menezes; T, Venkatesh

    2009-01-01

    The objective of this study was to evaluate the role of minerals on lead-induced effect on the liver. Differentiation of minerals and heavy metals pose an inherent problem due to certain common properties shared by them. With this approach to the problem of heavy metal toxicity, in the present study two groups of male Wistar albino rats, one group (well-nourished) fed on mineral rich diet and other group (undernourished) fed on diet without mineral supplements were used. Both the groups of rats were subjected to long-term lead exposure. The diet of well-nourished group was supplemented with calcium (Ca); 1.2%, phosphorous (P); 0.6%, iron (Fe); 90 mg/kg, zinc (Zn); 50 mg/kg, magnesium (Mg); 0.08%, manganese (Mn); 70 mg/kg, selenium (Se); 0.2 mg/kg, copper (Cu); 5 mg/kg, molybdenum (Mo); 0.8 mg/kg, iodine (I); 0.6 mg/kg, cobalt (Co); 3.0 mg/kg. Their blood lead and parameters of liver function were monitored periodically. Results of the study showed a very high statistically significant increase (p < 0.001) in the blood lead (PbB) levels and liver function test parameters in the undernourished subjects compared to the well-nourished subjects. Nutritional management of lead poisoning is of importance since essential elements and toxic heavy metals may interact to minimize the absorption of lead.

  6. Influence of minerals on lead-induced alterations in liver function in rats exposed to long-term lead exposure

    Energy Technology Data Exchange (ETDEWEB)

    Herman, D' souza Sunil, E-mail: hermansdsouza@rediffmail.com [Department of Biotechnology, Manipal Life Sciences Centre, KMC, Manipal University, Manipal (India); Geraldine, Menezes, E-mail: gere1@rediffmail.com [Department of Biochemistry and Biophysics, St. John' s Medical College, Koramangala, Bangalore 560034, Karnataka (India); T, Venkatesh, E-mail: venky_tv@hotmail.com [Department of Biochemistry and Biophysics, St. John' s Medical College, Koramangala, Bangalore 560034, Karnataka (India)

    2009-07-30

    The objective of this study was to evaluate the role of minerals on lead-induced effect on the liver. Differentiation of minerals and heavy metals pose an inherent problem due to certain common properties shared by them. With this approach to the problem of heavy metal toxicity, in the present study two groups of male Wistar albino rats, one group (well-nourished) fed on mineral rich diet and other group (undernourished) fed on diet without mineral supplements were used. Both the groups of rats were subjected to long-term lead exposure. The diet of well-nourished group was supplemented with calcium (Ca); 1.2%, phosphorous (P); 0.6%, iron (Fe); 90 mg/kg, zinc (Zn); 50 mg/kg, magnesium (Mg); 0.08%, manganese (Mn); 70 mg/kg, selenium (Se); 0.2 mg/kg, copper (Cu); 5 mg/kg, molybdenum (Mo); 0.8 mg/kg, iodine (I); 0.6 mg/kg, cobalt (Co); 3.0 mg/kg. Their blood lead and parameters of liver function were monitored periodically. Results of the study showed a very high statistically significant increase (p < 0.001) in the blood lead (PbB) levels and liver function test parameters in the undernourished subjects compared to the well-nourished subjects. Nutritional management of lead poisoning is of importance since essential elements and toxic heavy metals may interact to minimize the absorption of lead.

  7. Different methods for modeling absorption heat transformer powered by solar pond

    International Nuclear Information System (INIS)

    Sencan, Arzu; Kizilkan, Onder; Bezir, Nalan C.; Kalogirou, Soteris A.

    2007-01-01

    Solar ponds are a type of solar collector used for storing solar energy at temperature below 90 o C. Absorption heat transformers (AHTs) are devices used to increase the temperature of moderately warm fluid to a more useful temperature level. In this study, a theoretical modelling of an absorption heat transformer for the temperature range obtained from an experimental solar pond with dimensions 3.5 x 3.5 x 2 m is presented. The working fluid pair in the absorption heat transformer is aqueous ternary hydroxide fluid consisting of sodium, potassium and caesium hydroxides in the proportions 40:36:24 (NaOH:KOH:CsOH). Different methods such as linear regression (LR), pace regression (PR), sequential minimal optimization (SMO), M5 model tree, M5' rules, decision table and back propagation neural network (BPNN) are used for modelling the absorption heat transformer. The best results were obtained by the back propagation neural network model. A new formulation based on the BPNN is presented to determine the flow ratio (FR) and the coefficient of performance (COP) of the absorption heat transformer. The BPNN procedure is more accurate and requires significantly less computation time than the other methods

  8. Low adolescent self-esteem leads to multiple interpersonal problems: a test a social-adaptation theory.

    Science.gov (United States)

    Kahle, L R; Kulka, R A; Klingel, D M

    1980-09-01

    This article reports the results of a study that annually monitored the self-esteem and interpersonal problems of over 100 boys during their sophomore, junior, and senior years of high school. Cross-lagged panel correlation differences show that low self-esteem leads to interpersonal problems in all three time lags when multiple interpersonal problems constitute the dependent variable but not when single interpersonal problem criteria constitute the dependent variable. These results are interpreted as supporting social-adaptation theory rather than self-perception theory. Implications for the conceptual status of personality variables as causal antecedents and for the assessment of individual differences are discussed.

  9. Effects of warm-up on vertical jump performance and muscle electrical activity using half-squats at low and moderate intensity.

    Science.gov (United States)

    Sotiropoulos, Konstantinos; Smilios, Ilias; Christou, Marios; Barzouka, Karolina; Spaias, Angelos; Douda, Helen; Tokmakidis, Savvas P

    2010-01-01

    The purpose of this study was to determine the effects of a specific warm-up using half-squats at low and moderate intensity on vertical jump performance and electromyographic activity of the thigh muscles. The subjects were 26 men who were divided into a low intensity group (LIG; n = 13) and a moderate intensity group (MIG; n = 13). The LIG performed a specific warm-up protocol that included the explosive execution of half-squats with loads 25 and 35% of the one repetition maximum (1RM) and the MIG with loads 45 and 65% of the 1RM. The two groups performed a countermovement jump (CMJ) before and three minutes after the specific warm-up protocols. During the concentric phase of the CMJ a linear encoder connected to an A/D converter interfaced to a PC with a software for data acquisition and analysis allowed the calculation of average mechanical power. The electromyographic (EMG) activity of the vastus lateralis (VL), vastus medialis (VM) and rectus femoris (RF) were recorded during the concentric phase of the jumps. The average quadriceps (Qc) activity (mean value of the VL, VM and RF) was also calculated. A two way ANOVA (protocols X time) with repeated measures on the second factor was used to analyze the data. Following the specific warm-up procedure both groups improved (p ≤ 0.05) CMJ performance and mechanical power by 3.5% and 6.3%, respectively, with no differences observed between the two groups. EMG activity of the Qc and VL increased (p ≤ 0.05) for both groups by 5.9% and 8.5%, respectively. It is concluded that the use of a specific warm-up that includes half-squats, performed explosively with low to moderate intensity, improves CMJ performance. This may be due to increased muscle activation as evaluated by the surface EMG. Key pointsThe inclusion of two sets of explosively performed half squats with low to moderate loads in the warm up procedure elicited an acute performance en-hancement.The performance was enhanced regardless of the load used in

  10. Does oxytocin lead to emotional interference during a working memory paradigm?

    Science.gov (United States)

    Tollenaar, Marieke S; Ruissen, M; Elzinga, B M; de Bruijn, E R A

    2017-12-01

    Oxytocin administration may increase attention to emotional information. We hypothesized that this augmented emotional processing might in turn lead to interference on concurrent cognitive tasks. To test this hypothesis, we examined whether oxytocin administration would lead to heightened emotional interference during a working memory paradigm. Additionally, moderating effects of childhood maltreatment were explored. Seventy-eight healthy males received 24 IU of intranasal oxytocin or placebo in a randomized placebo-controlled double-blind between-subjects study. A working memory task was performed during which neutral, positive, and negative distractors were presented. The main outcome observed was that oxytocin did not enhance interference by emotional information during the working memory task. There was a non-significant trend for oxytocin to slow down performance irrespective of distractor valence, while accuracy was unaffected. Exploratory analyses showed that childhood maltreatment was related to lower overall accuracy, but in the placebo condition only. However, the maltreated group sample size was very small precluding any conclusions on its moderating effect. Despite oxytocin's previously proposed role in enhanced emotional processing, no proof was found that this would lead to reduced performance on a concurrent cognitive task. The routes by which oxytocin exerts its effects on cognitive and social-emotional processes remain to be fully elucidated.

  11. Heat transfer measurements on an incidence-tolerant low pressure turbine blade in a high speed linear cascade at low to moderate Reynolds numbers

    Science.gov (United States)

    Moualeu, Leolein Patrick Gouemeni

    Runway-independent aircraft are expected to be the future for short-haul flights by improving air transportation and reducing area congestion encountered in airports. The Vehicle Systems Program of NASA identified a Large Civil Tilt-Rotor, equipped with variable-speed power-turbine engines, as the best concept. At cruise altitude, the engine rotor-speed will be reduced by as much as the 50% of take-off speed. The large incidence variation in the low pressure turbine associated with the change in speed can be detrimental to the engine performance. Low pressure turbine blades in cruise altitude are more predisposed to develop regions of boundary layer separation. Typical phenomenon such as impinging wakes on downstream blades and mainstream turbulences enhance the complexity of the flow in low pressure turbines. It is therefore important to be able to understand the flow behavior to accurately predict the losses. Research facilities are seldom able to experimentally reproduce low Reynolds numbers at relevant engine Mach number. Having large incidence swing as an additional parameter in the investigation of the boundary layer development, on a low pressure turbine blade, makes this topic unique and as a consequence requires a unique facility to conduct the experimental research. The compressible flow wind tunnel facility at the University of North Dakota had been updated to perform steady state experiments on a modular-cascade, designed to replicate a large variation of the incidence angles. The high speed and low Reynolds number facility maintained a sealed and closed loop configuration for each incidence angle. The updated facility is capable to produce experimental Reynolds numbers as low as 45,000 and as high as 570,000 at an exit Mach number of 0.72. Pressure and surface temperature measurements were performed at these low pressure turbine conditions. The present thesis investigates the boundary layer development on the surface of an Incidence-tolerant blade. The

  12. Numerical predictions of dry oxidation of iron and low-carbon steel at moderately elevated temperatures

    International Nuclear Information System (INIS)

    Henshall, G.A.

    1996-11-01

    Wrought and cast low-carbon steel are candidate materials for the thick (e.g. 10 cm) outer barrier of nuclear waste packages being considered for use in the potential geological repository at Yucca Mountain. Dry oxidation is possible at the moderately elevated temperatures expected at the container surface (323-533 K or 50-260 C). Numerical predictions of dry oxidation damage were made based on experimental data for iron and low-carbon steel and parabolic oxidation theory. The Forward Euler method was implemented to integrate the parabolic rate law for arbitrary, complex temperature histories. Assuming growth of a defect-free, adherent oxide, the surface penetration of a low-carbon steel barrier following 5000 years of exposure to a severe, but repository-relevant, temperature history is predicted to be only about 0.127 mm, less than 0.13% of the expected container thickness of 10 cm. Allowing the oxide to spall upon reaching a critical thickness increases the predicted metal penetration values, but degradation is still computed to be negligible. Thus, dry oxidation is not expected to significantly degrade the performance of thick, corrosion allowance barriers constructed of low-carbon steel

  13. Low-level lead exposure and autistic behaviors in school-age children.

    Science.gov (United States)

    Kim, Kyoung-Nam; Kwon, Ho-Jang; Hong, Yun-Chul

    2016-03-01

    The association between lead exposure and autism spectrum disorder is inconclusive. We hypothesized an association between higher blood lead concentrations and more autistic behaviors, including impaired social interactions and communication, stereotypical behaviors, and restricted interests, among school-age children. Data from 2473 Korean children aged 7-8years who had no prior history of developmental disorders were analyzed. Two follow-up surveys were conducted biennially until the children reached 11-12years of age. Blood lead concentrations were measured at every survey, and autistic behaviors were evaluated at 11-12years of age using the Autism Spectrum Screening Questionnaire (ASSQ) and Social Responsiveness Scale (SRS). The associations of blood lead concentration with ASSQ and SRS scores were analyzed using negative binomial, logistic, and linear regression models. Blood lead concentrations at 7-8years of age (geometric mean: 1.64μg/dL), but not at 9-10 and 11-12years of age, were associated with more autistic behaviors at 11-12years of age, according to the ASSQ (β=0.151; 95% confidence interval [CI]: 0.061, 0.242) and SRS (β=2.489; 95% CI: 1.378, 3.600). SRS subscale analysis also revealed associations between blood lead concentrations and social awareness, cognition, communication, motivation, and mannerisms. Even low blood lead concentrations at 7-8years of age are associated with more autistic behaviors at 11-12years of age, underscoring the need for continued efforts to reduce lead exposure. Copyright © 2016. Published by Elsevier B.V.

  14. Thermal hydraulic simulation of moderator heat exchanger

    International Nuclear Information System (INIS)

    Anil Lal, S.; Rajakumar, A.; Vaidyanathan, G.; Srinivasan, R.; Chetal, S.C.

    1993-01-01

    Pressurized heavy water reactors form the majority in the first stage of India's nuclear power programme. Heavy water is both moderator and primary coolant. The heat generated in the moderator due to neutron moderation and capture has to be removed in moderator heat exchangers. It has been desired to improve the performance characteristics of moderator heat exchangers, whereby moderator would enter the calandria vessel at a low temperature and would enable higher power of operation for the same limiting temperature of moderator in the calandria. Results of studies carried out using a three dimensional computer code for various operating options are given. Using these velocities the heat exchangers have been analysed for flow induced vibrations. 7 refs., 6 figs., 6 tabs

  15. Infrared-laser spectroscopy using a long-pathlength absorption cell

    International Nuclear Information System (INIS)

    Kim, K.C.; Briesmeister, R.A.

    1983-01-01

    The absorption measurements in an ordinary cell may require typically a few torr pressure of sample gas. At these pressures the absorption lines are usually pressure-broadened and, therefore, closely spaced transitions are poorly resolved even at diode-laser resolution. This situation is greatly improved in Doppler-limited spectroscopy at extremely low sample pressures. Two very long-pathlength absorption cells were developed to be used in conjunction with diode lasers. They were designed to operate at controlled temperatures with the optical pathlength variable up to approx. 1.5 km. Not only very low sample pressures are used for studies with such cells but also the spectroscopic sensitivity is enhanced over conventional methods by a factor of 10 3 to 10 4 , improving the analytical capability of measuring particle densities to the order of 1 x 10'' molecules/cm 3 . This paper presents some analytical aspects of the diode laser spectroscopy using the long-pathlength absorption cells in the areas of absorption line widths, pressure broadening coefficients, isotope composition measurements and trace impurity analysis

  16. Metal-core/semiconductor-shell nanocones for broadband solar absorption enhancement.

    Science.gov (United States)

    Zhou, Lin; Yu, Xiaoqiang; Zhu, Jia

    2014-02-12

    Nanostructure-based photovoltaic devices have exhibited several advantages, such as reduced reflection, extraordinary light trapping, and so forth. In particular, semiconductor nanostructures provide optical modes that have strong dependence on the size and geometry. Metallic nanostructures also attract a lot of attention because of the appealing plasmonic effect on the near-field enhancement. In this study, we propose a novel design, the metal-core/semiconductor-shell nanocones with the core radius varying in a linearly gradient style. With a thin layer of semiconductor absorber coated on a metallic cone, such a design can lead to significant and broadband absorption enhancement across the entire visible and near-infrared solar spectrum. As an example of demonstration, a layer of 16 nm thick crystalline silicon (c-Si) coated on a silver nanocone can absorb 27% of standard solar radiation across a broad spectral range of 300-1100 nm, which is equivalent to a 700 nm thick flat c-Si film. Therefore, the absorption enhancement factor approaching the Yablonovitch limit is achieved with this design. The significant absorption enhancement can be ascribed to three types of optical modes, that is, Fabry-Perot modes, plasmonic modes, and hybrid modes that combine the features of the previous two. In addition, the unique nanocone geometry enables the linearly gradient radius of the semiconductor shell, which can support multiple optical resonances, critical for the broadband absorption. Our design may find general usage as elements for the low cost, high efficiency solar conversion and water-splitting devices.

  17. Characteristics of transplacental lead transfer in rat dams and fetuses

    International Nuclear Information System (INIS)

    Kopfler, F.C.; Miller, R.G.; Kowal, N.E.; Kelty, K.C.; Doerger, J.U.; Mills, T.

    1987-01-01

    This study was designed to quantitate the dose resulting from lead exposure during the critical periods of brain development during gestation by determining: (1) if blood lead concentration in rat dams is affected by pregnancy status or duration of lead exposure, (2) if lead concentration in fetuses is associated with the duration of dam exposure, (3) the rates of lead absorption and elimination in pregnant and nonpregnant dams; and (4) the effect that prebreeding exposure on lead kinetics in the dam and upon fetus blood lead concentrations. The results of experiments in which the dams' drinking water contained 50 mg/L lead indicate blood lead levels (after normalizing by water consumption on a body weight basis) of pregnant rats are significantly higher than blood lead levels of non-pregnant rats. Statistical differences in blood lead levels were observed by day 15 of gestation and continue through day 20 of gestation. These blood lead differences are not due to lead treatment prior to breeding as seen when comparing Figure 1 and Figure 2. The blood lead levels of the fetuses at day 20 of gestation were 50-60% higher than that of the corresponding dams. The results from the latter two phases were ambiguous, due to large variability in individual animal absorption and elimination rates. However, the following observations can be made. Preexposure to lead does not affect the percent of lead transferred from the dams' blood to the fetuses. The rate of elimination of lead from the dams' blood does not appear to be affected by prebreeding exposure to lead or by the status of pregnancy. The fraction of the 203 Pb dose transferred to the fetus increases dramatically toward the end of gestation. The data suggest that lead absorption from the gut of pregnant rats is higher than that for nonpregnant rats

  18. Treatment patterns and low-density lipoprotein cholesterol (LDL-C) goal attainment among patients receiving high- or moderate-intensity statins.

    Science.gov (United States)

    Fox, Kathleen M; Tai, Ming-Hui; Kostev, Karel; Hatz, Maximilian; Qian, Yi; Laufs, Ulrich

    2018-05-01

    European clinical guidelines recommend a low-density lipoprotein cholesterol (LDL-C) goal of C goal attainment among atherosclerotic CV disease (ASCVD) patients with various utilization patterns of moderate- or high-intensity statins in routine care. This retrospective cohort study used electronic medical records data from the QuintilesIMS® Disease Analyzer (> 2 million individuals annually) to identify ASCVD (coronary atherosclerosis, stable/unstable angina, myocardial infarction, ischemic stroke, transient ischemic attack, aneurysm, peripheral artery disease) patients on moderate-/high-intensity statin in Germany. Proportion of patients with LDL-C C value for each patient (index) in 2012, 2013, and 2014, while on statin. Treatment patterns were assessed for patients with at least 1 year of post-index follow-up. Results were stratified by year and treatment pattern [no change, switch, dose up-/down-titration, discontinuation (≥ 90 day gap)]. In > 14,000 patients assessed in each year (mean age 71 years, 35% female, 8-12% taking high-intensity statins), approximately 80% had LDL-C ≥ 70 mg/dL. Treatment patterns were assessed for most (88-93%) patients. Approximately 79-81% of patients made no change to statin regimens, 1% switched statins, 14-16% discontinued; 1% of moderate-intensity patients up-titrated, and 3% of all patients down-titrated. LDL-C goal attainment in these treatment pattern groups was 20, 16-24, 17, 11-14, and 17-19%, respectively. Majority of ASCVD patients had LDL-C ≥ 70 mg/dL while on moderate-/high-intensity statins. Despite low LDL-C goal attainment, few patients changed their treatment regimens.

  19. Levels of lead in foods from the first French total diet study on infants and toddlers.

    Science.gov (United States)

    Guérin, Thierry; Le Calvez, Emilie; Zinck, Julie; Bemrah, Nawel; Sirot, Véronique; Leblanc, Jean-Charles; Chekri, Rachida; Hulin, Marion; Noël, Laurent

    2017-12-15

    Infants and toddlers are highly vulnerable to exposure to lead due to its higher absorption in small children than in adults. This study describes the optimisation and validation of a very sensitive method for the determination of low levels of lead in foods mostly consumed by infants and toddlers. This method, based on inductively coupled plasma-mass spectrometry with a programmable temperature cyclonic spray chamber, attained a limit of quantification (LOQ) of 0.6 or 0.9µgPbkg -1 for a liquid or a solid sample, that was improved by a factor 5.6-8.3 compared to the previous method (LOQ: 5µgkg -1 ). The analytical method was then applied to 291 food samples from the first French total diet study on infants and toddlers. Lead was detected in most samples at relatively low concentrations (range 0.0-16µgkg -1 ). The highest lead concentrations were mainly found in processed food products (e.g. products containing chocolate). Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Predictors of patient dependence in mild-to-moderate Alzheimer's disease.

    Science.gov (United States)

    Benke, Thomas; Sanin, Günter; Lechner, Anita; Dal-Bianco, Peter; Ransmayr, Gerhard; Uranüs, Margarete; Marksteiner, Josef; Gaudig, Maren; Schmidt, Reinhold

    2015-01-01

    Patient dependence has rarely been studied in mild-to-moderate Alzheimer's disease (AD). To identify factors which predict patient dependence in mild-to-moderate AD. We studied 398 non-institutionalized AD patients (234 females) of the ongoing Prospective Registry on Dementia (PRODEM) in Austria. The Dependence Scale (DS) was used to assess patient dependence. Patient assessment comprised functional abilities, neuropsychiatric symptoms and cognitive functions. A multiple linear regression analysis was performed to identify predictors of patient dependence. AD patients were mildly-to-moderately impaired (mean scores and SDs were: CDR 0.84 ± 0.43; DAD 74.4 ± 23.3, MMSE = 22.5 ± 3.6). Psychopathology and caregiver burden were in the low range (mean NPI score 13.2, range 0 to 98; mean ZBI score 18, range 0-64). Seventy five percent of patients were classified as having a mild level of patient dependence (DS sum score 0 to 6). Patient dependence correlated significantly and positively with age, functional measures, psychopathology and depression, disease duration, and caregiver burden. Significant negative, but low correlations were found between patient dependence, cognitive variables, and global cognition. Activities of daily living, patient age, and disease severity accounted for 63% of variance in patient dependence, whereas cognitive variables accounted for only 11%. Dependence in this cohort was mainly related to age and functional impairment, and less so to cognitive and neuropsychiatric variables. This differs from studies investigating patients in more advanced disease stages which found abnormal behavior and impairments of cognition as main predictors of patient dependence.