WorldWideScience

Sample records for low-intensity ultrasound increases

  1. Skin temperature increase mediated by wearable, long duration, low-intensity therapeutic ultrasound

    Science.gov (United States)

    Langer, Matthew D.; Huang, Wenyi; Ghanem, Angi; Guo, Yuan; Lewis, George K.

    2017-03-01

    One of the safety concerns with the delivery of therapeutic ultrasound is overheating of the transducer-skin interface due to poor or improper coupling. The objective of this research was to define a model that could be used to calculate the heating in the skin as a result of a novel, wearable long-duration ultrasound device. This model was used to determine that the maximum heating in the skin remained below the minimum threshold necessary to cause thermal injury over multiple hours of use. In addition to this model data, a human clinical study used wire thermocouples on the skin surface to measure heating characteristics during treatment with the sustained ultrasound system. Parametric analysis of the model determined that the maximum temperature increase is at the surface of the skin ranged from 40-41.8° C when perfusion was taken into account. The clinical data agreed well with the model predictions. The average steady state temperature observed across all 44 subjects was 40°C. The maximum temperature observed was less than 44° C, which is clinically safe for over 5 hours of human skin contact. The resultant clinical temperature data paired well with the model data suggesting the model can be used for future transducer and ultrasound system design simulation. As a result, the device was validated for thermal safety for typical users and use conditions.

  2. Low-intensity pulsed ultrasound: Nonunions

    Directory of Open Access Journals (Sweden)

    Dijkman Bernadette

    2009-01-01

    Full Text Available Nonunions occur in 5-10% of fractures and are characterized by the failure to heal without further intervention. Low intensity pulsed ultrasound therapy has been developed as an alternative to surgery in the treatment of nonunions. We describe a systematic review on trials of low-intensity pulsed ultrasound therapy for healing of nonunions. We searched the electronic databases Medline and the Cochrane library for articles on ultrasound and healing of nonunions published up to 2008. Trials selected for the review met the following criteria: treatment of at least one intervention group with low intensity pulsed ultrasound; inclusion of patients (humans with one or more nonunions (defined as "established" or as a failure to heal for a minimum of eight months after initial injury; and assessment of healing and time to healing, as determined radiographically. The following data were abstracted from the included studies: sample size, ultrasound treatment characteristics, nonunion location, healing rate, time to fracture healing, fracture age, and demographic information. We found 79 potentially eligible publications, of which 14 met our inclusion criteria. Of these, eight studies were used for data abstraction. Healing rates averaged 87%, (range 65.6%-100% among eight trials. Mean time to healing was 146.5 days, (range 56-219 days. There is evidence from trials that low-intensity pulsed ultrasound may be an effective treatment for healing of nonunions. More homogeneous and larger controlled series are needed to further investigate its efficacy.

  3. Effects of low intensity pulsed ultrasound with and without increased cortical porosity on structural bone allograft incorporation

    Directory of Open Access Journals (Sweden)

    Ehrhart Nicole

    2008-05-01

    Full Text Available Abstract Background Though used for over a century, structural bone allografts suffer from a high rate of mechanical failure due to limited graft revitalization even after extended periods in vivo. Novel strategies that aim to improve graft incorporation are lacking but necessary to improve the long-term clinical outcome of patients receiving bone allografts. The current study evaluated the effect of low-intensity pulsed ultrasound (LIPUS, a potent exogenous biophysical stimulus used clinically to accelerate the course of fresh fracture healing, and longitudinal allograft perforations (LAP as non-invasive therapies to improve revitalization of intercalary allografts in a sheep model. Methods Fifteen skeletally-mature ewes were assigned to five experimental groups based on allograft type and treatment: +CTL, -CTL, LIPUS, LAP, LIPUS+LAP. The +CTL animals (n = 3 received a tibial ostectomy with immediate replacement of the resected autologous graft. The -CTL group (n = 3 received fresh frozen ovine tibial allografts. The +CTL and -CTL groups did not receive LAP or LIPUS treatments. The LIPUS treatment group (n = 3, following grafting with fresh frozen ovine tibial allografts, received ultrasound stimulation for 20 minutes/day, 5 days/week, for the duration of the healing period. The LAP treatment group (n = 3 received fresh frozen ovine allografts with 500 μm longitudinal perforations that extended 10 mm into the graft. The LIPUS+LAP treatment group (n = 3 received both LIPUS and LAP interventions. All animals were humanely euthanized four months following graft transplantation for biomechanical and histological analysis. Results After four months of healing, daily LIPUS stimulation of the host-allograft junctions, alone or in combination with LAP, resulted in 30% increases in reconstruction stiffness, paralleled by significant increases (p Conclusion The current study has demonstrated in a large animal model the potential of both LIPUS and LAP

  4. Low-intensity pulsed ultrasound: Fracture healing

    Directory of Open Access Journals (Sweden)

    Mundi Raman

    2009-01-01

    Full Text Available Annually, millions of people across the world are inflicted with bone fracture injuries. Untimely healing is a significant burden in terms of socioeconomic costs, personal costs, and patients′ quality of life. Low-intensity pulsed ultrasound (LIPUS has gained much attention as a potential adjunctive therapy for accelerating fresh fracture healing, but its efficacy remains controversial. This paper is presented in two parts a literature review followed by a systematic review. The literature review highlights the physiology of fracture healing and the influence LIPUS exerts on cells and molecules involved in this healing process. In part two, we present a systematic review of randomized controlled trials (RCTs assessing the clinical effectiveness of LIPUS in accelerating the time to fracture healing. The electronic databases we searched for the systematic review are as follows: MEDLINE (from 1996 to November 2008, EMBASE (from 1996 to November 2008, and Healthstar (from 1966 to October 2008. A two-step screening process was used to assess the eligibility of studies yielded by our search. The first step was a review of titles and abstracts for the selection of studies that met the following criteria: (i inclusion of skeletally mature patients with a fresh fracture, (ii a minimum of two treatment arms with at least one arm receiving LIPUS treatment and another arm receiving placebo, (iii random allocation of patients to the different treatment arms, (iv radiological assessment of time to fracture healing, and (v publication in the English language. In the second step, selected articles were reviewed in full text. Eligible trials were all scored independently by two reviewers for methodological reporting quality using the 15-item CLEAR NPT checklist (Checklist to Evaluate the Report of a Nonpharmacological Trial. We identified a total of seventy seven studies, nine of which met our inclusion criteria after the initial screening. Of these nine

  5. Combined Treatment of Alendronate and Low-Intensity Pulsed Ultrasound (LIPUS Increases Bone Mineral Density at the Cancellous Bone Osteotomy Site in Aged Rats: A Preliminary Study.

    Directory of Open Access Journals (Sweden)

    H Aonuma

    2011-12-01

    Full Text Available Introduction: During fracture healing, alendronate encourages callus volume by inhibiting bone resorption, whereas low-intensity pulsed ultrasound (LIPUS enhances bone regeneration by promoting an anabolic response. Methods: In the present study, 9-month-old Sprague-Dawley rats, with a unilateral proximal tibial osteotomy, were treated with alendronate (daily, 1 g/kg plus sham-LIPUS (n = 14, saline plus LIPUS (20 min/day (n = 18, alendronate plus LIPUS (n = 16, or saline plus sham- LIPUS as a control (n = 13 for 4 weeks. The rats were then examined for changes in bone mineral density (BMD during metaphyseal bone repair. Results: The combined therapy signi cantly increased BMD at the osteotomy site at 4 weeks (p < 0.001 compared with the control, without affecting the contralateral, non-osteotomized tibia. Both alendronate and LIPUS alone also exerted a positive, albeit less, effect on BMD in the affected limb (p < 0.001 and p = 0.006, respectively. Conclusions: Alendronate and LIPUS cooperate to enhance BMD during metaphyseal bone healing. Keywords: LIPUS, bisphosphonate, bone mineral density.

  6. A REVIEW OF LOW-INTENSITY ULTRASOUND FOR CANCER THERAPY

    Science.gov (United States)

    WOOD, ANDREW K. W.; SEHGAL, CHANDRA M.

    2015-01-01

    The literature describing the use of low-intensity ultrasound in four major areas of cancer therapy was reviewed - sonodynamic therapy, ultrasound mediated chemotherapy, ultrasound mediated gene delivery and antivascular ultrasound therapy. Each technique consistently resulted in the death of cancer cells and the bioeffects of ultrasound were primarily attributed to thermal actions and inertial cavitation. In each therapeutic modality, theranostic contrast agents composed of microbubbles played a role in both therapy and vascular imaging. The development of these agents is important as it establishes a therapeutic-diagnostic platform which can monitor the success of anti-cancer therapy. Little attention, however, has been given to either the direct assessment of the underlying mechanisms of the observed bioeffects or to the viability of these therapies in naturally occurring cancers in larger mammals; if such investigations provided encouraging data there could be a prompt application of a therapy technique in treating cancer patients. PMID:25728459

  7. Intramuscular Heating Characteristics of Multihour Low-Intensity Therapeutic Ultrasound.

    Science.gov (United States)

    Rigby, Justin H; Taggart, Rebecca M; Stratton, Kelly L; Lewis, George K; Draper, David O

    2015-11-01

    The heating characteristics of a stationary device delivering sustained acoustic medicine with low-intensity therapeutic ultrasound (LITUS) are unknown. To measure intramuscular (IM) heating produced by a LITUS device developed for long-duration treatment of musculoskeletal injuries. Controlled laboratory study. University research laboratory. A total of 26 healthy volunteers (16 men, 10 women; age = 23.0 ± 2.1 years, height = 1.74 ± 0.09 m, mass = 73.48 ± 14.65 kg). Participants were assigned randomly to receive active (n = 20) or placebo (n = 6) LITUS at a frequency of 3 MHz and an energy intensity of 0.132 W/cm(2) continuously for 3 hours with a single transducer or dual transducers on the triceps surae muscle. We measured IM temperature using thermocouples inserted at 1.5- and 3-cm depths into muscle. Temperatures were recorded throughout treatment and 30 minutes posttreatment. We used 2-sample t tests to determine the heating curve of the LITUS treatment and differences in final temperatures between depth and number of transducers. A mild IM temperature increase of 1 °C was reached 10 ± 5 minutes into the treatment, and a more vigorous temperature increase of 4 °C was reached 80 ± 10 minutes into the treatment. The maximal steady-state IM temperatures produced during the final 60 minutes of treatment at the 1.5-cm depth were 4.42 °C ± 0.08 °C and 3.92 °C ± 0.06 °C using 1 and 2 transducers, respectively. At the 3.0-cm depth, the maximal steady-state IM temperatures during the final 60 minutes of treatment were 3.05 °C ± 0.09 °C and 3.17 °C ± 0.05 °C using 1 and 2 transducers, respectively. We observed a difference between the temperatures measured at each depth (t78 = -2.45, P = .02), but the number of transducers used to generate heating was not different (t78 = 1.79, P = .08). The LITUS device elicited tissue heating equivalent to traditional ultrasound but could be sustained for multiple hours. It is a safe and effective alternative tool

  8. Low-intensity pulsed ultrasound stimulation for mandibular condyle osteoarthritis lesions in rats.

    Science.gov (United States)

    Kanaguchi Arita, A; Yonemitsu, I; Ikeda, Y; Miyazaki, M; Ono, T

    2018-05-01

    This study evaluated low-intensity pulsed ultrasound effects for temporomandibular joint osteoarthritis in adult rats. Osteoarthritis-like lesions were induced in 24 adult rats' temporomandibular joints with low-dose mono-iodoacetate injections. The rats were divided into four groups: control and mono-iodoacetate groups, injected with contrast media and mono-iodoacetate, respectively, at 12 weeks and observed until 20 weeks; and low-intensity pulsed ultrasound and mono-iodoacetate + low-intensity pulsed ultrasound groups, injected with contrast media and mono-iodoacetate, respectively, at 12 weeks with low-intensity pulsed ultrasound performed from 16 to 20 weeks. Condylar bone mineral density, bone mineral content and bone volume were evaluated weekly with microcomputed tomography. Histological and immunohistochemical staining for matrix metalloproteinases-13 was performed at 20 weeks. At 20 weeks, the mono-iodoacetate + low-intensity pulsed ultrasound group showed significantly higher bone mineral density, bone mineral content and bone volume than the mono-iodoacetate group; however, these values remained lower than those in the other two groups. On histological and immunohistochemical analysis, the chondrocytes were increased, and fewer matrix metalloproteinases-13 immunopositive cells were identified in the mono-iodoacetate + low-intensity pulsed ultrasound group than mono-iodoacetate group. Low-intensity pulsed ultrasound for 2 weeks may have therapeutic potential for treating temporomandibular joint osteoarthritis lesions. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Low-intensity pulsed ultrasound increases bone volume, osteoid thickness and mineral apposition rate in the area of fracture healing in patients with a delayed union of the osteotomized fibula

    NARCIS (Netherlands)

    Rutten, S.; Nolte, P.A.; Korstjens, C.M.; van Duin, M.A.; Klein-Nulend, J.

    2008-01-01

    Introduction Low-intensity pulsed ultrasound (LIPUS) accelerates impaired fracture healing, but the exact mechanism is unknown. The aim of this study was to investigate how LIPUS affects bone healing at the tissue level in patients with a delayed union of the osteotomized fibula, by using histology

  10. Pulsed-low intensity ultrasound enhances extracellular matrix production by fibroblasts encapsulated in alginate

    Directory of Open Access Journals (Sweden)

    Siti PM Bohari

    2012-12-01

    Full Text Available In this study, the effect of pulsed-low intensity ultrasound on cell proliferation, collagen production and glycosaminoglycan deposition by 3T3 fibroblasts encapsulated in alginate was evaluated. Hoechst 33258 assay for cell number, hydroxyproline assay for collagen content and dimethylamine blue assay for glycosaminoglycan content were performed on samples from cell cultures treated with pulsed-low intensity ultrasound and a control group. Pulsed-low intensity ultrasound shows no effect on cell proliferation, while collagen and glycosaminoglycan contents were consistently higher in the samples treated with pulsed-low intensity ultrasound, showing a statistically significant difference (p < 0.05 on day 10. Alcian blue staining showed that glycosaminoglycans were deposited around the cells in both groups. These results suggest that pulsed-low intensity ultrasound shows no effect on cell proliferation but has potential for inducing collagen and glycosaminoglycan production in cells cultured in alginate gels.

  11. Effect of low-frequency low-intensity ultrasound with microbubbles on prostate cancer hypoxia.

    Science.gov (United States)

    Hou, Rui; Xu, Yanjun; Lu, Qijie; Zhang, Yang; Hu, Bing

    2017-10-01

    Angiogenesis plays an important role in tumor growth, invasiveness, and metastasis. It is well established that prostate cancer is exposed to fluctuating oxygen tensions and both acute and chronic hypoxia exist, and these conditions can upregulate angiogenesis-associated proteins such as hypoxia-inducible factor 1 alpha and vascular endothelial growth factor A. Low-frequency low-intensity ultrasound with microbubbles can induce obvious microvessel damage in tumors, cause cell necrosis or apoptosis. However, there is no information about whether the blocking blood effect of low-frequency low-intensity ultrasound with microbubbles has an influence on hypoxia environment of prostate cancer. Therefore, we investigated the impact of different low-frequency low-intensity ultrasound with microbubbles radiation times on prostate tumors, observed the change in the hypoxia-inducible factor 1 alpha and vascular endothelial growth factor A protein levels, as well as cell proliferation, apoptosis, and tumor volume. The results indicated that as the radiation was repeated four times on each treatment day, the effects of interruption were durable, the cell proliferation was inhibited, and apoptosis was promoted, and the hypoxia-inducible factor 1 alpha and vascular endothelial growth factor A expression levels were lower in the treatment group than in the control group. When the radiation was carried out once per treatment day, the hypoxia response was stimulated, the hypoxia-inducible factor 1 alpha and vascular endothelial growth factor A expression levels were higher compared with the control group, and cell proliferation was promoted. In addition, the tumor volume increased obviously in the hypoxia-stimulated group, whereas tumors grew slowly in the hypoxia-suppressed group. The results of this work demonstrated that under the same conditions, different radiation times of low-frequency low-intensity ultrasound with microbubbles affect the hypoxia response differently, and the

  12. Low-intensity pulsed ultrasound affects human articular chondrocytes in vitro

    NARCIS (Netherlands)

    Korstjens, C.M.; van der Rijt, R.H.H.; Albers, G.H.; Semeins, C.M.; Klein-Nulend, J.

    2008-01-01

    We investigated whether low-intensity pulsed ultrasound (LIPUS) stimulates chondrocyte proliferation and matrix production in explants of human articular cartilage obtained from donors suffering from unicompartimental osteoarthritis of the knee, as well as in isolated human chondrocytes in vitro.

  13. Low intensity pulsed ultrasound (LIPUS) for bone healing: A clinical practice guideline

    NARCIS (Netherlands)

    R.W. Poolman (Rudolf); Agoritsas, T. (Thomas); Siemieniuk, R.A.C. (Reed A C); I. Harris (Ian); I.B. Schipper (Inger); Mollon, B. (Brent); Smith, M. (Maureen); Albin, A. (Alexandra); Nador, S. (Sally); Sasges, W. (Will); S. Schandelmaier; Lytvyn, L. (Lyubov); T. Kuijpers (Ton); Van Beers, L.W.A.H. (Loes W A H); M.H.J. Verhofstad (Michiel); P.O. Vandvik (Per)

    2017-01-01

    textabstractDoes low intensity pulsed ultrasound (LIPUS) accelerate recovery in adults and children who have experienced bone fractures or osteotomy (cutting of a bone)? An expert panel rapidly produced these recommendations based on a linked systematic review triggered by a large multi-centre

  14. The Safety of Using High Frequency, Low Intensity Ultrasound to Enhance Thrombolysis

    International Nuclear Information System (INIS)

    Soltani, Azita

    2006-01-01

    The EKOS Ultrasound Infusion Systems (EKOS Corporation, Bothell, WA) use high frequency, low intensity ultrasound to accelerate thrombolysis by enhancing clot permeability and lytic drug penetration into thrombus. These systems are designed to provide efficacious catheter-directed treatment for the management of stroke, peripheral arterial occlusion and deep vein thrombosis. The in vitro and in vivo results of investigating the stability of therapeutic and diagnostic compounds used in combination with EKOS devices, the potential for adverse biological effects and the clot fragmentation confirmed the safety of EKOS ultrasound infusion systems in thrombolysis treatment

  15. Effects of Low Intensity Continuous Ultrasound (LICU on Mouse Pancreatic Tumor Explants

    Directory of Open Access Journals (Sweden)

    Despina Bazou

    2017-12-01

    Full Text Available This paper describes the effects of low intensity continuous ultrasound (LICU on the inflammatory response of mouse pancreatic tumor explants. While there are many reports focusing on the application of low-intensity pulsed ultrasound (LIPUS on cell cultures and tissues, the effects of continuous oscillations on biological tissues have never been investigated. Here we present an exploratory study of the effects induced by LICU on mouse pancreatic tumor explants. We show that LICU causes significant upregulation of IFN-γ, IL-1β, and TNF-α on tumor explants. No detectable effects were observed on tumor vasculature or collagen I deposition, while thermal and mechanical effects were not apparent. Tumor explants responded as a single unit to acoustic waves, with spatial pressure variations smaller than their size.

  16. Low-intensity pulsed ultrasound accelerates tooth movement via activation of the BMP-2 signaling pathway.

    Directory of Open Access Journals (Sweden)

    Hui Xue

    Full Text Available The present study was designed to determine the underlying mechanism of low-intensity pulsed ultrasound (LIPUS induced alveolar bone remodeling and the role of BMP-2 expression in a rat orthodontic tooth movement model. Orthodontic appliances were placed between the homonymy upper first molars and the upper central incisors in rats under general anesthesia, followed by daily 20-min LIPUS or sham LIPUS treatment beginning at day 0. Tooth movement distances and molecular changes were evaluated at each observation point. In vitro and in vivo studies were conducted to detect HGF (Hepatocyte growth factor/Runx2/BMP-2 signaling pathways and receptor activator of NFκB ligand (RANKL expression by quantitative real time PCR (qRT-PCR, Western blot and immunohistochemistry. At day 3, LIPUS had no effect on the rat orthodontic tooth movement distance and BMP-2-induced alveolar bone remodeling. However, beginning at day 5 and for the following time points, LIPUS significantly increased orthodontic tooth movement distance and BMP-2 signaling pathway and RANKL expression compared with the control group. The qRT-PCR and Western blot data in vitro and in vivo to study BMP-2 expression were consistent with the immunohistochemistry observations. The present study demonstrates that LIPUS promotes alveolar bone remodeling by stimulating the HGF/Runx2/BMP-2 signaling pathway and RANKL expression in a rat orthodontic tooth movement model, and LIPUS increased BMP-2 expression via Runx2 regulation.

  17. Low-intensity pulsed ultrasound regulates proliferation and differentiation of osteoblasts through osteocytes

    International Nuclear Information System (INIS)

    Li, Lei; Yang, Zheng; Zhang, Hai; Chen, Wenchuan; Chen, Mengshi; Zhu, Zhimin

    2012-01-01

    Highlights: ► CM from LIPUS-stimulated osteocytes inhibits proliferation of osteoblasts. ► CM from LIPUS-stimulated osteocytes enhances differentiation of osteoblasts. ► LIPUS stimulates MLO-Y4 cells to secrete PGE 2 and NO. -- Abstract: Low-intensity pulsed ultrasound (LIPUS) has been used as a safe and effective modality to enhance fracture healing. As the most abundant cells in bone, osteocytes orchestrate biological activities of effector cells via direct cell-to-cell contacts and by soluble factors. In this study, we have used the osteocytic MLO-Y4 cells to study the effects of conditioned medium from LIPUS-stimulated MLO-Y4 cells on proliferation and differentiation of osteoblastic MC3T3-E1 cells. Conditioned media from LIPUS-stimulated MLO-Y4 cells (LIPUS-Osteocyte-CM) were collected and added on MC3T3-E1 cell cultures. MC3T3-E1 cells cultured in LIPUS-Osteocyte-CM demonstrated a significant inhibition of proliferation and an increased alkaline phosphatase activity. The results of PGE 2 and NO assay showed that LIPUS could enhance PGE 2 and NO secretion from MLO-Y4 cells at all time points within 24 h after LIPUS stimulation. We conclude that LIPUS regulates proliferation and differentiation of osteoblasts through osteocytes in vitro. Increased secretion of PGE 2 from osteocytes may play a role in this effect.

  18. Low-intensity pulsed ultrasound enhances bone formation around miniscrew implants.

    Science.gov (United States)

    Ganzorig, Khaliunaa; Kuroda, Shingo; Maeda, Yuichi; Mansjur, Karima; Sato, Minami; Nagata, Kumiko; Tanaka, Eiji

    2015-06-01

    Miniscrew implants (MSIs) are currently used to provide absolute anchorage in orthodontics; however, their initial stability is an issue of concern. Application of low-intensity pulsed ultrasound (LIPUS) can promote bone healing. Therefore, LIPUS application may stimulate bone formation around MSIs and enhance their initial stability. To investigate the effect of LIPUS exposure on bone formation after implantation of titanium (Ti) and stainless steel (SS) MSIs. MSIs made of Ti-6Al-4V and 316L SS were placed on rat tibiae and treated with LIPUS. The bone morphology around MSIs was evaluated by scanning electron microscopy and three-dimensional micro-computed tomography. MC3T3-E1 cells cultured on Ti and SS discs were treated with LIPUS, and the temporary expression of alkaline phosphatase (ALP) was examined. Bone-implant contact increased gradually from day 3 to day 14 after MSI insertion. LIPUS application increased the cortical bone density, cortical bone thickness, and cortical bone rate after implantation of Ti and SS MSIs (P<0.05). LIPUS exposure induced ALP upregulation in MC3T3-E1 cells at day 3 (P<0.05). LIPUS enhanced bone formation around Ti and SS MSIs, enhancing the initial stability of MSIs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Low-intensity pulsed ultrasound regulates proliferation and differentiation of osteoblasts through osteocytes

    Energy Technology Data Exchange (ETDEWEB)

    Li, Lei, E-mail: geraldleelei@163.com [State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu (China); Yang, Zheng [State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu (China); Zhang, Hai [Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA (United States); Chen, Wenchuan [State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu (China); Chen, Mengshi [Department of Biomechanics, Sichuan University, Chengdu (China); Zhu, Zhimin, E-mail: hxzhimin@163.com [State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu (China)

    2012-02-10

    Highlights: Black-Right-Pointing-Pointer CM from LIPUS-stimulated osteocytes inhibits proliferation of osteoblasts. Black-Right-Pointing-Pointer CM from LIPUS-stimulated osteocytes enhances differentiation of osteoblasts. Black-Right-Pointing-Pointer LIPUS stimulates MLO-Y4 cells to secrete PGE{sub 2} and NO. -- Abstract: Low-intensity pulsed ultrasound (LIPUS) has been used as a safe and effective modality to enhance fracture healing. As the most abundant cells in bone, osteocytes orchestrate biological activities of effector cells via direct cell-to-cell contacts and by soluble factors. In this study, we have used the osteocytic MLO-Y4 cells to study the effects of conditioned medium from LIPUS-stimulated MLO-Y4 cells on proliferation and differentiation of osteoblastic MC3T3-E1 cells. Conditioned media from LIPUS-stimulated MLO-Y4 cells (LIPUS-Osteocyte-CM) were collected and added on MC3T3-E1 cell cultures. MC3T3-E1 cells cultured in LIPUS-Osteocyte-CM demonstrated a significant inhibition of proliferation and an increased alkaline phosphatase activity. The results of PGE{sub 2} and NO assay showed that LIPUS could enhance PGE{sub 2} and NO secretion from MLO-Y4 cells at all time points within 24 h after LIPUS stimulation. We conclude that LIPUS regulates proliferation and differentiation of osteoblasts through osteocytes in vitro. Increased secretion of PGE{sub 2} from osteocytes may play a role in this effect.

  20. No midterm benefit from low intensity pulsed ultrasound after chevron osteotomy for hallux valgus.

    Science.gov (United States)

    Zacherl, Max; Gruber, Gerald; Radl, Roman; Rehak, Peter H; Windhager, Reinhard

    2009-08-01

    Chevron osteotomy is a widely accepted method for correction of symptomatic hallux valgus deformity. Full weight bearing in regular shoes is not recommended before 6 weeks after surgery. Low intensity pulsed ultrasound is known to stimulate bone formation leading to more stable callus and faster bony fusion. We performed a randomized, placebo-controlled, double-blinded study on 44 participants (52 feet) who underwent chevron osteotomy to evaluate the influence of daily transcutaneous low intensity pulsed ultrasound (LIPUS) treatment at the site of osteotomy. Follow-up at 6 weeks and 1 year included plain dorsoplantar radiographs, hallux-metatarsophalangeal-interphalangeal scale and a questionnaire on patient satisfaction. There was no statistical difference in any pre- or postoperative clinical features, patient satisfaction or radiographic measurements (hallux valgus angle, intermetatarsal angle, sesamoid index and metatarsal index) except for the first distal metatarsal articular angle (DMAA). The DMAA showed statistically significant (p = 0.046) relapse in the placebo group upon comparison of intraoperative radiographs after correction and fixation (5.2 degrees) and at the 6-week follow-up (10.6 degrees). Despite potential impact of LIPUS on bone formation, we found no evidence of an influence on outcome 6 weeks and 1 year after chevron osteotomy for correction of hallux valgus deformity.

  1. Effect of low-intensity pulsed ultrasound on bone regeneration: biochemical and radiologic analyses.

    Science.gov (United States)

    Pomini, Karina T; Andreo, Jesus C; Rodrigues, Antonio de C; de O Gonçalves, Jéssica B; Daré, Letícia R; German, Iris J S; Rosa, Geraldo M; Buchaim, Rogerio L

    2014-04-01

    The purpose of this study was to evaluate the effects of low-intensity pulsed ultrasound at 1.0 MHz on the healing process of fractures with bone loss in the rat fibula by alkaline phosphate level measurement and radiologic analyses. Thirty 70-day-old male Wistar rats underwent a bone resection of 2.5 to 3.0 mm between the proximal and middle third of the right fibular diaphysis. The animals were randomly divided into 3 experimental groups: reference (uninjured), control (injured only), and treated (injured and treated with 5 applications of ultrasound, interspersed by 2 days of rest, beginning 24 hours after the osteotomy). Euthanasia was performed at experimental periods of 7 and 14 days. The right hind limb was removed for radiologic analysis. The blood was collected via cardiac puncture to determine the serum alkaline phosphatase activity. The bone fractures had not been completely consolidated in the treated and control group when analysis of the bone took place. At day 7, the serum alkaline phosphatase activity was higher in the treated group (mean ± SD, 72.17 ± 7.02 U/L) compared to the control (65.26 ± 8.41 U/L) and reference (67.21 ± 7.86 U/L) groups. At day 14, higher alkaline phosphatase activity was seen in the control group (68.96 ± 8.12 U/L) compared to the treated (66.09 ± 8.46 U/L) and reference (67.14 ± 7.96 U/L) groups. The biochemical and radiologic results suggest that low-intensity pulsed ultrasound can be used as an auxiliary method to consolidate fractures and probably reduces the bone healing time, offering clinical benefits.

  2. Drug Release from Phase-Changeable Nanodroplets Triggered by Low-Intensity Focused Ultrasound

    Science.gov (United States)

    Cao, Yang; Chen, Yuli; Yu, Tao; Guo, Yuan; Liu, Fengqiu; Yao, Yuanzhi; Li, Pan; Wang, Dong; Wang, Zhigang; Chen, Yu; Ran, Haitao

    2018-01-01

    Background: As one of the most effective triggers with high tissue-penetrating capability and non-invasive feature, ultrasound shows great potential for controlling the drug release and enhancing the chemotherapeutic efficacy. In this study, we report, for the first time, construction of a phase-changeable drug-delivery nanosystem with programmable low-intensity focused ultrasound (LIFU) that could trigger drug-release and significantly enhance anticancer drug delivery. Methods: Liquid-gas phase-changeable perfluorocarbon (perfluoropentane) and an anticancer drug (doxorubicin) were simultaneously encapsulated in two kinds of nanodroplets. By triggering LIFU, the nanodroplets could be converted into microbubbles locally in tumor tissues for acoustic imaging and the loaded anticancer drug (doxorubicin) was released after the microbubble collapse. Based on the acoustic property of shell materials, such as shell stiffness, two types of nanodroplets (lipid-based nanodroplets and PLGA-based nanodroplets) were activated by different acoustic pressure levels. Ultrasound irradiation duration and power of LIFU were tested and selected to monitor and control the drug release from nanodroplets. Various ultrasound energies were introduced to induce the phase transition and microbubble collapse of nanodroplets in vitro (3 W/3 min for lipid nanodroplets; 8 W/3 min for PLGA nanodroplets). Results: We detected three steps in the drug-releasing profiles exhibiting the programmable patterns. Importantly, the intratumoral accumulation and distribution of the drug with LIFU exposure were significantly enhanced, and tumor proliferation was substantially inhibited. Co-delivery of two drug-loaded nanodroplets could overcome the physical barriers of tumor tissues during chemotherapy. Conclusion: Our study provides a new strategy for the efficient ultrasound-triggered chemotherapy by nanocarriers with programmable LIFU capable of achieving the on-demand drug release. PMID:29507623

  3. Review Paper: A Review on Brain Stimulation Using Low Intensity Focused Ultrasound

    Directory of Open Access Journals (Sweden)

    Ehsan Rezayat

    2016-07-01

    Full Text Available Brain stimulation techniques are important in both basic and clinical studies. Majority of well-known brain stimulating techniques have low spatial resolution or entail invasive processes. Low intensity focused ultrasound (LIFU seems to be a proper candidate for dealing with such deficiencies. This review recapitulates studies which explored the effects of LIFU on brain structures and its function, in both research and clinical areas. Although the mechanism of LIFU action is still unclear, its different effects from molecular level up to behavioral level can be explored in animal and human brain. It can also be coupled with brain imaging assessments in future research.

  4. Complex tibial fracture outcomes following treatment with low-intensity pulsed ultrasound.

    Science.gov (United States)

    Leung, Kwok-Sui; Lee, Wing-Sze; Tsui, Hon-For; Liu, Paul Po-Lung; Cheung, Wing-Hoi

    2004-03-01

    A clinical study was conducted to investigate the effect of low-intensity pulsed ultrasound (US) stimulation (LIPUS) on the healing of complex tibial fractures. Thirty complex tibial fractures were randomly assigned to the treatment with LIPUS (n = 16) or by a dummy machine (sham-exposed: n = 14). The fractures were immobilized by either internal or external fixations according to the clinical indications. LIPUS was given 20 min/day for 90 days. Fracture healing was monitored by clinical, radiological, densitometric and biochemical assessments. The LIPUS-treated group showed statistically significantly better healing, as demonstrated by all assessments. Complications were minimal in the LIPUS group. There were two cases of delayed union, with one in each group. There were two cases of infection in the control group. The delayed-union cases were subsequently treated by LIPUS and the infection cases were treated with standard protocol. Fracture healing in these patients was again treated by LIPUS.

  5. Low-intensity pulsed ultrasound stimulation facilitates osteogenic differentiation of human periodontal ligament cells.

    Directory of Open Access Journals (Sweden)

    Bo Hu

    Full Text Available Human periodontal ligament cells (hPDLCs possess stem cell properties, which play a key role in periodontal regeneration. Physical stimulation at appropriate intensities such as low-intensity pulsed ultrasound (LIPUS enhances cell proliferation and osteogenic differentiation of mesechymal stem cells. However, the impacts of LIPUS on osteogenic differentiation of hPDLCs in vitro and its molecular mechanism are unknown. This study was undertaken to investigate the effects of LIPUS on osteogenic differentiation of hPDLCs. HPDLCs were isolated from premolars of adolescents for orthodontic reasons, and exposed to LIPUS at different intensities to determine an optimal LIPUS treatment dosage. Dynamic changes of alkaline phosphatase (ALP activities in the cultured cells and supernatants, and osteocalcin production in the supernatants after treatment were analyzed. Runx2 and integrin β1 mRNA levels were assessed by reverse transcription polymerase chain reaction analysis after LIPUS stimulation. Blocking antibody against integrinβ1 was used to assess the effects of integrinβ1 inhibitor on LIPUS-induced ALP activity, osteocalcin production as well as calcium deposition. Our data showed that LIPUS at the intensity of 90 mW/cm2 with 20 min/day was more effective. The ALP activities in lysates and supernatants of LIPUS-treated cells started to increase at days 3 and 7, respectively, and peaked at day 11. LIPUS treatment significantly augmented the production of osteocalcin after day 5. LIPUS caused a significant increase in the mRNA expression of Runx2 and integrin β1, while a significant decline when the integrinβ1 inhibitor was used. Moreover, ALP activity, osteocalcin production as well as calcium nodules of cells treated with both daily LIPUS stimulation and integrinβ1 antibody were less than those in the LIPUS-treated group. In conclusion, LIPUS promotes osteogenic differentiation of hPDLCs, which is associated with upregulation of Runx2 and

  6. The effects of low-intensity pulsed ultrasound on tendon-bone healing in a transosseous-equivalent sheep rotator cuff model.

    Science.gov (United States)

    Lovric, Vedran; Ledger, Michael; Goldberg, Jerome; Harper, Wade; Bertollo, Nicky; Pelletier, Matthew H; Oliver, Rema A; Yu, Yan; Walsh, William R

    2013-02-01

    The purpose of this study was to examine the effects Low-intensity Pulsed Ultrasound has on initial tendon-bone healing in a clinically relevant extra-articular transosseous-equivalent ovine rotator cuff model. Eight skeletally mature wethers, randomly allocated to either control group (n = 4) or treatment group (n = 4), underwent rotator cuff surgery following injury to the infraspinatus tendon. All animals were killed 28 days post surgery to allow examination of early effects of Low-intensity Pulsed Ultrasound treatment. General improvement in histological appearance of tendon-bone integration was noted in the treatment group. Newly formed woven bone with increased osteoblast activity along the bone surface was evident. A continuum was observed between the tendon and bone in an interdigitated fashion with Sharpey's fibres noted in the treatment group. Low-intensity Pulsed Ultrasound treatment also increased bone mineral density at the tendon-bone interface (p < 0.01), while immunohistochemistry results revealed an increase in the protein expression patterns of VEGF (p = 0.038), RUNX2 (p = 0.02) and Smad4 (p = 0.05). The results of this study indicate that Low-intensity Pulsed Ultrasound may aid in the initial phase of tendon-bone healing process in patients who have undergone rotator cuff repair. This treatment may also be beneficial following other types of reconstructive surgeries involving the tendon-bone interface.

  7. Design of a Thermoacoustic Sensor for Low Intensity Ultrasound Measurements Based on an Artificial Neural Network.

    Science.gov (United States)

    Xing, Jida; Chen, Jie

    2015-06-23

    In therapeutic ultrasound applications, accurate ultrasound output intensities are crucial because the physiological effects of therapeutic ultrasound are very sensitive to the intensity and duration of these applications. Although radiation force balance is a benchmark technique for measuring ultrasound intensity and power, it is costly, difficult to operate, and compromised by noise vibration. To overcome these limitations, the development of a low-cost, easy to operate, and vibration-resistant alternative device is necessary for rapid ultrasound intensity measurement. Therefore, we proposed and validated a novel two-layer thermoacoustic sensor using an artificial neural network technique to accurately measure low ultrasound intensities between 30 and 120 mW/cm2. The first layer of the sensor design is a cylindrical absorber made of plexiglass, followed by a second layer composed of polyurethane rubber with a high attenuation coefficient to absorb extra ultrasound energy. The sensor determined ultrasound intensities according to a temperature elevation induced by heat converted from incident acoustic energy. Compared with our previous one-layer sensor design, the new two-layer sensor enhanced the ultrasound absorption efficiency to provide more rapid and reliable measurements. Using a three-dimensional model in the K-wave toolbox, our simulation of the ultrasound propagation process demonstrated that the two-layer design is more efficient than the single layer design. We also integrated an artificial neural network algorithm to compensate for the large measurement offset. After obtaining multiple parameters of the sensor characteristics through calibration, the artificial neural network is built to correct temperature drifts and increase the reliability of our thermoacoustic measurements through iterative training about ten seconds. The performance of the artificial neural network method was validated through a series of experiments. Compared to our previous

  8. Design evolution enhances patient compliance for low-intensity pulsed ultrasound device usage

    Directory of Open Access Journals (Sweden)

    Pounder NM

    2016-11-01

    Full Text Available Neill M Pounder, John T Jones, Kevin J Tanis Bioventus LLC, Durham, NC, USA Abstract: Poor patient compliance or nonadherence with prescribed treatments can have a significant unfavorable impact on medical costs and clinical outcomes. In the current study, voice-of-the-customer research was conducted to aid in the development of a next-generation low-intensity pulsed ultrasound (LIPUS bone healing product. An opportunity to improve patient compliance reporting was identified, resulting in the incorporation into the next-generation device of a visual calendar that provides direct feedback to the patient, indicating days for which they successfully completed treatment. Further ­investigation was done on whether inclusion of the visual calendar improved patient adherence to the prescribed therapy (20 minutes of daily treatment over a 6-month period. Thus, 12,984 data files were analyzed from patients prescribed either the earlier- or the next-generation LIPUS device. Over the 6-month period, overall patient compliance was 83.8% with the next-generation LIPUS device, compared with 74.2% for the previous version (p<0.0001. Incorporation of the calendar feature resulted in compliance never decreasing below 76% over the analysis period, whereas compliance with the earlier-generation product fell to 51%. A literature review on the LIPUS device shows a correlation between clinical effectiveness and compliance rates more than 70%. Incorporation of stakeholder feedback throughout the design and innovation process of a next-generation LIPUS device resulted in a measurable improvement in patient adherence, which may help to optimize clinical outcomes. Keywords: LIPUS, ultrasound, compliance, patient adherence, medical device design

  9. Design of a Thermoacoustic Sensor for Low Intensity Ultrasound Measurements Based on an Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Jida Xing

    2015-06-01

    Full Text Available In therapeutic ultrasound applications, accurate ultrasound output intensities are crucial because the physiological effects of therapeutic ultrasound are very sensitive to the intensity and duration of these applications. Although radiation force balance is a benchmark technique for measuring ultrasound intensity and power, it is costly, difficult to operate, and compromised by noise vibration. To overcome these limitations, the development of a low-cost, easy to operate, and vibration-resistant alternative device is necessary for rapid ultrasound intensity measurement. Therefore, we proposed and validated a novel two-layer thermoacoustic sensor using an artificial neural network technique to accurately measure low ultrasound intensities between 30 and 120 mW/cm2. The first layer of the sensor design is a cylindrical absorber made of plexiglass, followed by a second layer composed of polyurethane rubber with a high attenuation coefficient to absorb extra ultrasound energy. The sensor determined ultrasound intensities according to a temperature elevation induced by heat converted from incident acoustic energy. Compared with our previous one-layer sensor design, the new two-layer sensor enhanced the ultrasound absorption efficiency to provide more rapid and reliable measurements. Using a three-dimensional model in the K-wave toolbox, our simulation of the ultrasound propagation process demonstrated that the two-layer design is more efficient than the single layer design. We also integrated an artificial neural network algorithm to compensate for the large measurement offset. After obtaining multiple parameters of the sensor characteristics through calibration, the artificial neural network is built to correct temperature drifts and increase the reliability of our thermoacoustic measurements through iterative training about ten seconds. The performance of the artificial neural network method was validated through a series of experiments. Compared

  10. Low-intensity pulsed ultrasound (LIPUS) and pulsed electromagnetic field (PEMF) treatments affect degeneration of cultured articular cartilage explants

    NARCIS (Netherlands)

    Tan, Lijun; Ren, Yijin; van Kooten, Theo G.; Grijpma, Dirk W.; Kuijer, Roelof

    PURPOSE: Articular cartilage has some capacity for self-repair. Clinically used low-intensity pulsed ultrasound (LIPUS) and pulsed electromagnetic field (PEMF) treatments were compared in their potency to prevent degeneration using an explant model of porcine cartilage. METHODS: Explants of porcine

  11. Low-intensity pulsed ultrasound (LIPUS) and pulsed electromagnetic field (PEMF) treatments affect degeneration of cultured articular cartilage explants

    NARCIS (Netherlands)

    Tan, Lijun; Tan, Lijun; Ren, Yijin; van Kooten, Theo G.; Grijpma, Dirk W.; Kuijer, Roel

    2015-01-01

    Purpose: Articular cartilage has some capacity for self-repair. Clinically used low-intensity pulsed ultrasound (LIPUS) and pulsed electromagnetic field (PEMF) treatments were compared in their potency to prevent degeneration using an explant model of porcine cartilage. Methods: Explants of porcine

  12. Apoptosis induced by low-intensity ultrasound in vitro: Alteration of protein profile and potential molecular mechanism

    Science.gov (United States)

    Feng, Yi; Wan, Mingxi

    2017-03-01

    To analyze the potential mechanism related to the apoptosis induced by low intensity focused ultrasound, comparative proteomic method was introduced in the study. After ultrasound irradiation (3.0 W/cm2, 1 minute, 6 hours incubation post-irradiation), the human SMMC-7721 hepatocarcinoma cells were stained by trypan blue to detect the morphologic changes, and then the percentage of early apoptosis were tested by the flow cytometry with double staining of FITC-labelled Annexin V/Propidium iodide. Two-dimensional SDS polyacrylamide gel electrophoresis was used to get the protein profile and some proteins differently expressed after ultrasound irradiation were identified by MALDI-TOF mass spectrometry. It's proved early apoptosis of cells were induced by low intentisy focused ultrasound. After ultrasound irradiation, the expressing characteristics of several proteins changed, in which protein p53 and heat shock proteins are associated with apoptosis initiation. It is suggested that the low-intensity ultrasound-induced apoptotic cancer therapy has the potential application via understanding its relevant molecular signaling and key proteins. Moreover, the comparative proteomic method is proved to be useful to supply information about the protein expression to analyze the metabolic processes related to bio-effects of biomedical ultrasound.

  13. Effects of low-intensity pulsed ultrasound on injured skeletal muscle

    Directory of Open Access Journals (Sweden)

    Camila S. Montalti

    2013-08-01

    Full Text Available BACKGROUND: Low-intensity pulsed ultrasound (LIPUS has been shown to stimulate tissue metabolism and accelerate muscle healing. However, the optimal parameters in the use of LIPUS are still not clear. OBJECTIVE: The aim of this study was to analyze the effects of LIPUS on muscle healing in rats subjected to a cryolesion. METHOD: Twenty rats were divided into the following groups: an injured control group (CG and an injured treated group (TG. Both groups were divided into 2 sub-groups (n=5 each that were sacrificed 7 and 13 days post-surgery. Treatments were started 24 hours after the surgical procedure and consisted of 3 or 6 sessions. After euthanasia, the muscles were submitted to standard histological procedures. RESULTS: Qualitative analyses were based on morphological assessments of the muscle. The histopathological analysis on day 7 revealed that the muscles in the CG and the TG presented an intense inflammatory infiltrate, a large necrotic area and a disorganized tissue structure. After 13 days, both the CG and the TG had granulation tissue and newly formed fibers. The TG presented a more organized tissue structure. The quantitative analysis of collagen indicated similar findings among the groups, although the qualitative analysis revealed a better organization of collagen fibers in the TG at 13 days. The immunohistochemical analysis indicated that, at both time points, the expression of cyclooxygenase-2 was upregulated in the TG compared to the CG. CONCLUSIONS: LIPUS used as a treatment for muscle injury induced a more organized tissue structure at the site of the injury and stimulated the expression of COX-2 and the formation of new muscle fibers.

  14. Efficacy of low-intensity pulsed ultrasound in the prevention of osteoporosis following spinal cord injury.

    Science.gov (United States)

    Warden, S J; Bennell, K L; Matthews, B; Brown, D J; McMeeken, J M; Wark, J D

    2001-11-01

    Ultrasound (US), a high-frequency acoustic energy traveling in the form of a mechanical wave, represents a potential site-specific intervention for osteoporosis. Bone is a dynamic tissue that remodels in response to applied mechanical stimuli. As a form of mechanical stimulation, US is anticipated to produce a similar remodeling response. This theory is supported by growing in vitro and in vivo evidence demonstrating an osteogenic effect of pulsed-wave US at low spatial-averaged temporal-averaged intensities. The aim of this study was to investigate whether low-intensity pulsed US could prevent calcaneal osteoporosis in individuals following spinal cord injury (SCI). Fifteen patients with a 1-6 month history of SCI were recruited. Active US was introduced to one heel for 20 min/day, 5 days/week, over 6 weeks. The contralateral heel was simultaneously treated with inactive US. Patients were blind to which heel was being actively treated. Active US pulsed with a 10 microsec burst of 1.0 MHz sine waves repeating at 3.3 kHz. The spatial-averaged temporal-averaged intensity was set at 30 mW/cm(2). Bone status was assessed at baseline and following the intervention period by dual-energy X-ray absorptiometry and quantitative US. SCI resulted in significant bone loss. Bone mineral content decreased by 7.5 +/- 3.0% in inactive US-treated calcanei (p 0.05). These findings confirm the negative skeletal impact of SCI, and demonstrate that US at the dose and mode administered was not a beneficial intervention for SCI-induced osteoporosis. This latter finding may primarily relate to the inability of US to effectively penetrate the outer cortex of bone due to its acoustic properties.

  15. Modification of osteoarthritis in the guinea pig with pulsed low-intensity ultrasound treatment.

    Science.gov (United States)

    Gurkan, I; Ranganathan, A; Yang, X; Horton, W E; Todman, M; Huckle, J; Pleshko, N; Spencer, R G

    2010-05-01

    The Hartley guinea pig develops articular cartilage degeneration similar to that seen in idiopathic human osteoarthritis (OA). We investigated whether the application of pulsed low-intensity ultrasound (PLIUS) to the Hartley guinea pig joint would prevent or attenuate the progression of this degenerative process. Treatment of male Hartley guinea pigs was initiated at the onset of degeneration (8 weeks of age) to assess the ability of PLIUS to prevent OA, or at a later age (12 months) to assess the degree to which PLIUS acted to attenuate the progression of established disease. PLIUS (30 mW/cm(2)) was applied to stifle joints for 20 min/day over periods ranging from 3 to 10 months, with contralateral limbs serving as controls. Joint cartilage histology was graded according to a modified Mankin scale to evaluate treatment effect. Immunohistochemical staining for interleukin-1 receptor antagonist (IL-1ra), matrix metalloproteinase (MMP)-3, MMP-13, and transforming growth factor (TGF)-beta1 was performed on the cartilage to evaluate patterns of expression of these proteins. PLIUS did not fully prevent cartilage degeneration in the prevention groups, but diminished the severity of the disease, with the treated joints showing markedly decreased surface irregularities and a much smaller degree of loss of matrix staining as compared to controls. PLIUS also attenuated disease progression in the groups with established disease, although to a somewhat lesser extent as compared to the prevention groups. Immunohistochemical staining demonstrated a markedly decreased degree of TGF-beta1 production in the PLIUS-treated joints. This indicates less active endogenous repair, consistent with the marked reduction in cartilage degradation. PLIUS exhibits the ability to attenuate the progression of cartilage degeneration in an animal model of idiopathic human OA. The effect was greater in the treatment of early, rather than established, degeneration. Published by Elsevier Ltd.

  16. Genes Responsive to Low-Intensity Pulsed Ultrasound in MC3T3-E1 Preosteoblast Cells

    Directory of Open Access Journals (Sweden)

    Yoshiaki Tabuchi

    2013-11-01

    Full Text Available Although low-intensity pulsed ultrasound (LIPUS has been shown to enhance bone fracture healing, the underlying mechanism of LIPUS remains to be fully elucidated. Here, to better understand the molecular mechanism underlying cellular responses to LIPUS, we investigated gene expression profiles in mouse MC3T3-E1 preosteoblast cells exposed to LIPUS using high-density oligonucleotide microarrays and computational gene expression analysis tools. Although treatment of the cells with a single 20-min LIPUS (1.5 MHz, 30 mW/cm2 did not affect the cell growth or alkaline phosphatase activity, the treatment significantly increased the mRNA level of Bglap. Microarray analysis demonstrated that 38 genes were upregulated and 37 genes were downregulated by 1.5-fold or more in the cells at 24-h post-treatment. Ingenuity pathway analysis demonstrated that the gene network U (up contained many upregulated genes that were mainly associated with bone morphology in the category of biological functions of skeletal and muscular system development and function. Moreover, the biological function of the gene network D (down, which contained downregulated genes, was associated with gene expression, the cell cycle and connective tissue development and function. These results should help to further clarify the molecular basis of the mechanisms of the LIPUS response in osteoblast cells.

  17. Low-Intensity Pulsed Ultrasound Prevents the Oxidative Stress Induced Endothelial-Mesenchymal Transition in Human Aortic Endothelial Cells

    Directory of Open Access Journals (Sweden)

    Jiamin Li

    2018-02-01

    Full Text Available Background/Aims: Endothelial-mesenchymal transition (EndMT has been shown to take part in the generation and progression of diverse diseases, involving a series of changes leading to a loss of their endothelial characteristics and an acquirement of properties typical of mesenchymal cells. Low-intensity pulsed ultrasound (LIPUS is a new therapeutic option that has been successfully used in fracture healing. However, whether LIPUS can inhibit oxidative stress-induced endothelial cell damages through inhibiting EndMT remained unknown. This study aimed to investigate the protective effects of LIPUS against oxidative stress-induced endothelial cell damages and the underlying mechanisms. Methods: EndMT was induced by H2O2 (100 µm for seven days. Human aortic endothelial cells (HAECs were exposed to H2O2 with or without LIPUS treatment for seven days. The expression of EndMT markers (CD31, VE-cadherin, FSP1 and α-SMA were analyzed. The levels of total and phosphorylated PI3K and AKT proteins were detected by Western Blot analysis. Cell chemotaxis was determined by wound healing and transwell assay. Results: LIPUS relieved EndMT by decreasing ROS accumulation and increasing activation of the PI3K signaling cascade. LIPUS alleviated the migration of EndMT-derived mesenchymal-like cells through reducing extracellular matrix (ECM deposition that is associated with matrix metallopeptidase (MMP proteolytic activity and collagen production. Conclusion: LIPUS produces cytoprotective effects against oxidative injuries to endothelial cells through suppressing the oxidative stress-induced EndMT, activating the PI3K/AKT pathway under oxidative stress, and limiting cell migration and excessive ECM deposition.

  18. Low-intensity pulsed ultrasound is effective for progressive-stage lumbar spondylolysis with MRI high-signal change.

    Science.gov (United States)

    Arima, Hideyuki; Suzuki, Yoshiji; Togawa, Daisuke; Mihara, Yuki; Murata, Hideyuki; Matsuyama, Yukihiro

    2017-12-01

    This study aimed to investigate the treatment effects of low-intensity pulsed ultrasound (LIPUS) on progressive-stage spondylolysis. Spondylolysis is a stress fracture of the pars interarticularis. Based on the results of computed tomography, spondylolysis was classified into three categories: early, progressive, and terminal. Bone healing was prolonged or not obtained in progressive-stage spondylolysis. The progression of spondylolysis to nonunion has been associated with an increased incidence of spondylolisthesis. To prevent these clinical conditions, achieving bony healing of the spondylolysis site should be the goal of treatment. 15 consecutive pediatric patients with progressive-stage spondylolysis (defects) with MRI high-signal change were analyzed. Nine patients were treated conservative treatment including avoidance of any sport activity and the use of a brace during treatment (conventional). Six patients were treated using LIPUS everyday during treatment in addition to conservative treatment. Approximately every 1.5 months, bone healing was evaluated via CT. Cases that retained defects after 4.5 months were defined as nonunion. Two patients dropped out during the study period. A total of 13 patients (mean 14.6 ± 2.5 years) from the database met with 19 interarticularis defects. The bone union rate in LIPUS group was significantly higher than that in conventional group (66.7 vs. 10.0%, p = 0.020). The treatment period to bone union was 3.8 months and 2.7 ± 0.3 months in conventional and LIPUS groups. This study revealed that LIPUS treatment might be effective for bone union in patients with progressive-stage spondylolysis with MRI high-signal change. 4.

  19. Doxorubicin combined with low intensity ultrasound suppresses the growth of oral squamous cell carcinoma in culture and in xenografts

    Directory of Open Access Journals (Sweden)

    Haixia Fan

    2017-11-01

    Full Text Available Abstract Background Oral squamous cell carcinoma (OSCC invades surrounding tissues by upregulating matrix metalloproteinases (MMPs -2 and −9, which causes over-expression of the Hedgehog signaling proteins Shh and Gli-1 and degradation of the extracellular matrix, thereby creating a “highway” for tumor invasion. We explored the potential of low intensity ultrasound (LIUS and doxorubicin (DOX to inhibit the formation of this “highway”. Methods MTT assays were used to examine OSCC cell viability after exposure to LIUS and DOX. The cell morphological changes and ultrastructure were detected by scanning electron microscopy and transmission electron microscopy. Endogenous autophagy-associated proteins were analyzed by immunofluorescent staining and western blotting. Cell migration and invasion abilities were evaluated by Transwell assays. Collagen fiber changes were evaluated by Masson’s trichrome staining. Invasion-associated proteins were analyzed by immunohistochemistry and western blotting. Results LIUS of 1 W/cm2 increased the in vitro DOX uptake into OSCC by nearly 3-fold in three different cell lines and induced transient autophagic vacuoles on the cell surface. The combination of LIUS and 0.2 μg/ml DOX inhibited tumor cell viability and invasion, promoted tumor stromal collagen deposition, and prolonged the survival of mice. This combination also down-regulated MMP-2, MMP-9, Shh and Gli-1 in tumor xenografts. Collagen fiber expression was negatively correlated with the expression of these proteins in human OSCC samples. Conclusions Our findings suggest that effective low dosages of DOX in combination with LIUS can inhibit cell proliferation, migration and invasion, which might be through MMP-2/9 production mediated by the Hedgehog signaling pathway.

  20. High-Frequency, Low-Intensity Pulsed Ultrasound Enhances Alveolar Bone Healing of Extraction Sockets in Rats: A Pilot Study.

    Science.gov (United States)

    Kang, Kyung Lhi; Kim, Eun-Cheol; Park, Joon Bong; Heo, Jung Sun; Choi, Yumi

    2016-02-01

    Most studies of the beneficial effects of low-intensity pulsed ultrasound (LIPUS) on bone healing have used frequencies between 1.0 and 1.5 MHz. However, after consideration of ultrasound wave characteristics and depth of target tissue, higher-frequency LIPUS may have been more effective on superficially positioned alveolar bone. We investigated this hypothesis by applying LIPUS (frequency, 3.0 MHz; intensity, 30 mW/cm(2)) on shaved right cheeks over alveolar bones of tooth extraction sockets in rats for 10 min/d for 2 wk after tooth extraction; the control group (left cheek of the same rats) did not receive LIPUS treatment. Compared with the control group, the LIPUS group manifested more new bone growth inside the sockets on histomorphometric analysis (maximal difference = 2.5-fold on the seventh day after extraction) and higher expressions of osteogenesis-related mRNAs and proteins than the control group did. These findings indicate that 3.0-MHz LIPUS could enhance alveolar bone formation and calcification in rats. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Low-intensity continuous ultrasound triggers effective bisphosphonate anticancer activity in breast cancer.

    Science.gov (United States)

    Tardoski, Sophie; Ngo, Jacqueline; Gineyts, Evelyne; Roux, Jean-Paul; Clézardin, Philippe; Melodelima, David

    2015-11-18

    Ultrasound (US) is a non-ionizing pressure wave that can produce mechanical and thermal effects. Bisphosphonates have demonstrated clinical utility in bone metastases treatment. Preclinical studies suggest that bisphosphonates have anticancer activity. However, bisphosphonates exhibit a high affinity for bone mineral, which reduces their bioavailability for tumor cells. Ultrasound has been shown to be effective for drug delivery but in interaction with gas bubbles or encapsulated drugs. We examined the effects of a clinically relevant dose of bisphosphonate zoledronate (ZOL) in combination with US. In a bone metastasis model, mice treated with ZOL+US had osteolytic lesions that were 58% smaller than those of ZOL-treated animals as well as a reduced skeletal tumor burden. In a model of primary tumors, ZOL+US treatment reduced by 42% the tumor volume, compared with ZOL-treated animals. Using a fluorescent bisphosphonate, we demonstrated that US forced the release of bisphosphonate from the bone surface, enabling a continuous impregnation of the bone marrow. Additionally, US forced the penetration of ZOL within tumors, as demonstrated by the intratumoral accumulation of unprenylated Rap1A, a surrogate marker of ZOL antitumor activity. Our findings made US a promising modality to trigger bisphosphonate anticancer activity in bone metastases and in primary tumors.

  2. Effects and Mechanisms of Low-Intensity Pulsed Ultrasound for Chronic Prostatitis and Chronic Pelvic Pain Syndrome

    Directory of Open Access Journals (Sweden)

    Guiting Lin

    2016-07-01

    Full Text Available Chronic Prostatitis/Chronic Pelvic Pain Syndrome (CP/CPPS is one of the most common urologic diseases, and no curative treatments have been identified. Low-intensity pulsed ultrasound (LIPUS has been successfully used in promoting tissue healing, inhibiting inflammation and pain, differentiating stem cells, and stimulating nerve regeneration/muscle regeneration, as well as enhancing angiogenesis. Very recently, LIPUS has been proven an effective approach for CP/CPPS. This review summarizes the possible mechanisms responsible for the therapeutic effect of LIPUS for CP/CPPS. To search publications relevant to the topics of this review, the search engine for life sciences of Entrez was used. We reviewed the available evidence from 1954 through 2015 concerning LIPUS for CP/CPPS. According to the literature, both transrectal and transperineal approaches of LIPUS are effective for CP/CPPS.

  3. Low-Intensity Pulsed Ultrasound and Halo Immobilization Is an Effective Treatment for Nonunion Following Traumatic Spondylolisthesis of the Axis.

    Science.gov (United States)

    Oda, Kohtaroh; Ohba, Tetsuro; Ebata, Shigeto; Haro, Hirotaka

    2017-10-01

    This case report describes a unique case involving traumatic spondylolisthesis of the axis that resulted in nonunion, angulation, and displacement after conservative treatment with a cervical collar, but which was successfully achieved union with halo immobilization and low-intensity pulsed ultrasound (LIPUS). Halo immobilization of a traumatic spondylolisthesis in a 20-year-old patient, that previously failed to improve after wearing a cervical collar for 3 months, was immediately followed by treatment with a LIPUS device (SAFHS 4000J; Teijin Pharma, Tokyo, Japan) 20 minutes once daily to the right and left fracture sites which were located using fluoroscopic guidance. Radiographs and computed tomography showed conclusive evidence of bone union after 10 weeks of treatment with halo immobilization. No adverse events were observed. To the best of our knowledge, this is the first report describing that the combination of halo immobilization and LIPUS therapy might be a safe, effective, and feasible method by which to treat cervical spine fractures.

  4. Low-intensity pulsed ultrasound induces angiogenesis and ameliorates left ventricular dysfunction in a porcine model of chronic myocardial ischemia.

    Directory of Open Access Journals (Sweden)

    Kenichiro Hanawa

    Full Text Available Although a significant progress has been made in the management of ischemic heart disease (IHD, the number of severe IHD patients is increasing. Thus, it is crucial to develop new, non-invasive therapeutic strategies. In the present study, we aimed to develop low-intensity pulsed ultrasound (LIPUS therapy for the treatment of IHD.We first confirmed that in cultured human endothelial cells, LIPUS significantly up-regulated mRNA expression of vascular endothelial growth factor (VEGF with a peak at 32-cycle (P<0.05. Then, we examined the in vivo effects of LIPUS in a porcine model of chronic myocardial ischemia with reduced left ventricular ejection fraction (LVEF (n = 28. The heart was treated with either sham (n = 14 or LIPUS (32-cycle with 193 mW/cm2 for 20 min, n = 14 at 3 different short axis levels. Four weeks after the treatment, LVEF was significantly improved in the LIPUS group (46±4 to 57±5%, P<0.05 without any adverse effects, whereas it remained unchanged in the sham group (46±5 to 47±6%, P = 0.33. Capillary density in the ischemic region was significantly increased in the LIPUS group compared with the control group (1084±175 vs. 858±151/mm2, P<0.05. Regional myocardial blood flow was also significantly improved in the LIPUS group (0.78±0.2 to 1.39±0.4 ml/min/g, P<0.05, but not in the control group (0.84±0.3 to 0.97±0.4 ml/min/g. Western blot analysis showed that VEGF, eNOS and bFGF were all significantly up-regulated only in the LIPUS group.These results suggest that the LIPUS therapy is promising as a new, non-invasive therapy for IHD.

  5. Low-intensity focused ultrasound alters the latency and spatial patterns of sensory-evoked cortical responses in vivo

    Science.gov (United States)

    Fisher, Jonathan A. N.; Gumenchuk, Iryna

    2018-06-01

    Objective. The use of transcranial, low intensity focused ultrasound (FUS) is an emerging neuromodulation technology that shows promise for both therapeutic and research applications. Among many, one of the most exciting applications is the use of FUS to rehabilitate or augment human sensory capabilities. While there is compelling empirical evidence demonstrating this capability, basic questions regarding the spatiotemporal extent of the modulatory effects remain. Our objective was to assess the basic, yet often overlooked hypothesis that FUS in fact alters sensory-evoked neural activity within the region of the cerebral cortex at the beam’s focus. Approach. To address this knowledge gap, we developed an approach to optically interrogate patterns of neural activity in the cortex directly at the acoustic focus, in vivo. Implementing simultaneous wide-field optical imaging and FUS stimulation in mice, our experiments probed somatosensory-evoked electrical activity through the use of voltage sensitive dyes (VSDs) and, in transgenic mice expressing GCaMP6f, monitored associated Ca2+ responses. Main results. Our results demonstrate that low-intensity FUS alters both the kinetics and spatial patterns of neural activity in primary somatosensory cortex at the acoustic focus. When preceded by 1 s of pulsed ultrasound at intensities below 1 W cm‑2 (I sppa), the onset of sensory-evoked cortical responses occurred 3.0  ±  0.7 ms earlier and altered the surface spatial morphology of Ca2+ responses. Significance. These findings support the heretofore unconfirmed assumption that FUS-induced sensory modulation reflects, at least in part, altered reactivity in primary sensory cortex at the site of sonication. The findings are significant given the interest in using FUS to target and alter spatial aspects of sensory receptive fields on the cerebral cortex.

  6. Low-intensity focused ultrasound alters the latency and spatial patterns of sensory-evoked cortical responses in vivo.

    Science.gov (United States)

    Fisher, Jonathan A N; Gumenchuk, Iryna

    2018-02-13

    The use of transcranial, low intensity focused ultrasound (FUS) is an emerging neuromodulation technology that shows promise for both therapeutic and research applications. Among many, one of the most exciting applications is the use of FUS to rehabilitate or augment human sensory capabilities. While there is compelling empirical evidence demonstrating this capability, basic questions regarding the spatiotemporal extent of the modulatory effects remain. Our objective was to assess the basic, yet often overlooked hypothesis that FUS in fact alters sensory-evoked neural activity within the region of the cerebral cortex at the beam's focus. To address this knowledge gap, we developed an approach to optically interrogate patterns of neural activity in the cortex directly at the acoustic focus, in vivo. Implementing simultaneous wide-field optical imaging and FUS stimulation in mice, our experiments probed somatosensory-evoked electrical activity through the use of voltage sensitive dyes (VSDs) and, in transgenic mice expressing GCaMP6f, monitored associated Ca 2+ responses. Our results demonstrate that low-intensity FUS alters both the kinetics and spatial patterns of neural activity in primary somatosensory cortex at the acoustic focus. When preceded by 1 s of pulsed ultrasound at intensities below 1 W cm -2 (I sppa ), the onset of sensory-evoked cortical responses occurred 3.0  ±  0.7 ms earlier and altered the surface spatial morphology of Ca 2+ responses. These findings support the heretofore unconfirmed assumption that FUS-induced sensory modulation reflects, at least in part, altered reactivity in primary sensory cortex at the site of sonication. The findings are significant given the interest in using FUS to target and alter spatial aspects of sensory receptive fields on the cerebral cortex.

  7. Influence of low-intensity pulsed ultrasound on osteogenic tissue regeneration in a periodontal injury model: X-ray image alterations assessed by micro-computed tomography.

    Science.gov (United States)

    Wang, Yunji; Chai, Zhaowu; Zhang, Yuanyuan; Deng, Feng; Wang, Zhibiao; Song, Jinlin

    2014-08-01

    This study was conducted to evaluate, with micro-computed tomography, the influence of low-intensity pulsed ultrasound on wound-healing in periodontal tissues. Periodontal disease with Class II furcation involvement was surgically produced at the bilateral mandibular premolars in 8 adult male beagle dogs. Twenty-four teeth were randomly assigned among 4 groups (G): G1, periodontal flap surgery; G2, periodontal flap surgery+low-intensity pulsed ultrasound (LIPUS); G3, guided tissue regeneration (GTR) surgery; G4, GTR surgery plus LIPUS. The affected area in the experimental group was exposed to LIPUS. At 6 and 8weeks, the X-ray images of regenerated teeth were referred to micro-CT scanning for 3-D measurement. Bone volume (BV), bone surface (BS), and number of trabeculae (Tb) in G2 and G4 were higher than in G1 and G3 (pperiodontal flap surgery group. LIPUS irradiation increased the number, volume, and area of new alveolar bone trabeculae. LIPUS has the potential to promote the repair of periodontal tissue, and may work effectively if combined with GTR. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Low intensity pulsed ultrasound enhanced mesenchymal stem cell recruitment through stromal derived factor-1 signaling in fracture healing.

    Directory of Open Access Journals (Sweden)

    Fang-Yuan Wei

    Full Text Available Low intensity pulsed ultrasound (LIPUS has been proven effective in promoting fracture healing but the underlying mechanisms are not fully depicted. We examined the effect of LIPUS on the recruitment of mesenchymal stem cells (MSCs and the pivotal role of stromal cell-derived factor-1/C-X-C chemokine receptor type 4 (SDF-1/CXCR4 pathway in response to LIPUS stimulation, which are essential factors in bone fracture healing. For in vitro study, isolated rat MSCs were divided into control or LIPUS group. LIPUS treatment was given 20 minutes/day at 37 °C for 3 days. Control group received sham LIPUS treatment. After treatment, intracellular CXCR4 mRNA, SDF-1 mRNA and secreted SDF-1 protein levels were quantified, and MSCs migration was evaluated with or without blocking SDF-1/CXCR4 pathway by AMD3100. For in vivo study, fractured 8-week-old young rats received intracardiac administration of MSCs were assigned to LIPUS treatment, LIPUS+AMD3100 treatment or vehicle control group. The migration of transplanted MSC to the fracture site was investigated by ex vivo fluorescent imaging. SDF-1 protein levels at fracture site and in serum were examined. Fracture healing parameters, including callus morphology, micro-architecture of the callus and biomechanical properties of the healing bone were investigated. The in vitro results showed that LIPUS upregulated SDF-1 and CXCR4 expressions in MSCs, and elevated SDF-1 protein level in the conditioned medium. MSCs migration was promoted by LIPUS and partially inhibited by AMD3100. In vivo study demonstrated that LIPUS promoted MSCs migration to the fracture site, which was associated with an increase of local and serum SDF-1 level, the changes in callus formation, and the improvement of callus microarchitecture and mechanical properties; whereas the blockade of SDF-1/CXCR4 signaling attenuated the LIPUS effects on the fractured bones. These results suggested SDF-1 mediated MSCs migration might be one of the

  9. Low-Intensity Pulsed Ultrasound Protects Retinal Ganglion Cell From Optic Nerve Injury Induced Apoptosis via Yes Associated Protein

    Directory of Open Access Journals (Sweden)

    Jia-Xing Zhou

    2018-06-01

    Full Text Available Background: Low-intensity pulsed ultrasound (LIPUS has been used in clinical studies. But little is known about its effects on the central nervous system (CNS, or its mechanism of action. Retinal ganglion cells (RGCs are CNS neuronal cells that can be utilized as a classic model system to evaluate outcomes of LIPUS protection from external trauma-induced retinal injury. In this study, we aim to: (1 determine the pulse energy and the capability of LIPUS in RGC viability, (2 ascertain the protective role of LIPUS in optic nerve (ON crush-induced retinal injury, and 3 explore the cellular mechanisms of RGC apoptosis prevention by LIPUS.Methods: An ON crush model was set up to induce RGC death. LIPUS was used to treat mice eyes daily, and the retina samples were dissected for immunostaining and Western blot. The expression of yes-associated protein (YAP and apoptosis-related proteins was detected by immunostaining and Western blot in vitro and in vivo. Apoptosis of RGCs was evaluated by TUNEL staining, the survival of RGCs and retained axons were labeled by Fluoro-gold and Tuj1 antibody, respectively. Rotenone was used to set up an in vitro cellular degenerative model and siYAP was used to interfering the expression of YAP to detect the LIPUS protective function.Results: LIPUS protected RGC from loss and apoptosis in vivo and in vitro. The ratio of cleaved/pro-caspase3 also decreased significantly under LIPUS treatment. As a cellular mechanical sensor, YAP expression increased and YAP translocated to nucleus in LIPUS stimulation group, however, phospho-YAP was found to be decreased. When YAP was inhibited, the LIPUS could not protect RGC from caspase3-dependent apoptosis.Conclusion: LIPUS prevented RGCs from apoptosis in an ON crush model and in vitro cellular degenerative model, which indicates a potential treatment for further traumatic ON injury. The mechanism of protection is dependent on YAP activation and correlated with caspase-3 signaling.

  10. Effect of Low-Intensity Pulsed Ultrasound on Joint Injury and Post-Traumatic Osteoarthritis: an Animal Study.

    Science.gov (United States)

    Zahoor, Talal; Mitchell, Reed; Bhasin, Priya; Guo, Yi; Paudel, Sharada; Schon, Lew; Zhang, Zijun

    2018-01-01

    This study investigated the therapeutic potential of low-intensity pulsed ultrasound (LIPUS) in post-traumatic osteoarthritis (PTOA). Intra-articular fracture of the medial tibial plateau was surgically created in 30 rats. LIPUS was applied to the operated joints either for the first 2 wk (LIPUS 1-2 group) or in weeks 4 and 5 after intra-articular fracture (LIPUS 4-5 group). In controls, the operated knees were not treated with LIPUS (LIPUS 0 group). The rats were monitored with weekly gait analysis and euthanized at week 8. Among the altered gait parameters, the maximal and average paw print areas in the LIPUS 1-2 and LIPUS 4-5 groups, but not the LIPUS 0 group, had either reached baseline or significantly recovered (70%, p <0.05) by week 8. PTOA pathology in both the LIPUS 1-2 and LIPUS 4-5 groups was less severe than that in the LIPUS 0 group (Mankin score: 5.4 and 4.5 vs. 8.8, p <0.05). In conclusion, LIPUS treatment partially improved the gait of the affected limbs and reduced cartilage degeneration in PTOA. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  11. Circumvention of cisplatin resistance in ovarian cancer by combination of cyclosporin A and low-intensity ultrasound.

    Science.gov (United States)

    Yu, Tinghe; Yang, Yan; Zhang, Jiao; He, Haining; Ren, Xueyi

    2015-04-01

    Cisplatin resistance is a challenge in the treatment of ovarian cancer. The aim of this study was to explore if ultrasound can overcome chemoresistance and enhance chemosensitization due to cyclosporin A. Ultrasound and/or cyclosporin A were employed to overcome cisplatin resistance in human ovarian cancer cell line COC1/DDP. Mechanisms were explored from the perspective of: DNA damage, intracellular platinum level, detoxification, and genes related to drug efflux and DNA repair. In vivo therapeutic efficacy was validated in a short-term model (subrenal cell-clot transplantation) in mice and the survival benefit was investigated in an orthotopic cancer model in mice using HO-8910PM cells. The findings were: (i) ultrasound enhanced the effect of cisplatin leading to a lower cell-survival rate (IC50 decreased from 3.19 to 0.35 μg/ml); (ii) ultrasound enhanced cisplatin via direct (increasing the intercellular level of active platinum) and indirect (decreasing the glutathione level, and expression of LRP and ERCC1 genes) mechanisms that intensified cisplatin-induced DNA damage, thus enhancing cell apoptosis and necrosis; (iii) cisplatin followed by ultrasound led to small tumor sizes in the short-term model without exacerbation of the systemic toxicity, and prolonged the survival times in the orthotopic model; and (iv) ultrasound synergized the sensitization due to cyclosporin A in vitro and in vivo. These data demonstrated that ultrasound combined with cyclosporin A overcame cisplatin resistance in ovarian cancer. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Successful treatment of nonunion in severe finger injury with low-intensity pulsed ultrasound (LIPUS: a case report

    Directory of Open Access Journals (Sweden)

    Huber Michaela

    2012-07-01

    Full Text Available Abstract Introduction Severe injuries of the hand or single fingers require immediate treatment but surgical fixation methods are limited depending on soft tissue damage. Thus, it is very common that severe soft tissue damage along with poor osteosynthetic bone fixation results in a delayed healing process or nonunion. Low-intensity pulsed ultrasound (LIPUS has been proven to stimulate bone formation in in vitro studies and also to significantly accelerate nonunion healing in animal studies and clinical trials but to date there are no data with respect to nonunion in phalanx fracture. Case presentation We report a case in which we successfully used LIPUS in a 19-year-old Caucasian man with a nonunion of his ring finger after injury and first treatment with K-wire osteosynthesis. Conclusion We recommend that LIPUS be considered as an option to treat nonunions in fractures of the hand, especially because it is a soft tissue conserving method with a good functional result.

  13. [Research on ultrasonic permeability of low intensity pulsed ultrasound through PTFE membrane and Bio-Gide collagen membrane].

    Science.gov (United States)

    Chai, Zhaowu; Zhao, Chunliang; Song, Jinlin; Deng, Feng; Yang, Ji; Gao, Xiang; Liu, Minyi

    2013-12-01

    The aim of the present study was to detect the transmission rate of ultrasonic low intensity pulsed ultrasound (LIPUS) through polytetrafluoroethylene (PTFE) membrane (Thickness: 0.01 mm) and Bio-Gide collagen membrane, and to provide the basis for the barrier membrane selection on the study of LIPUS combined with guided tissue regeneration (GTR). The ultrasonic (LIPUS, frequency 1.5 MHz, pulse width 200 micros, repetition rate 1.0 kHz) transmission coefficient of the two kinds of barrier membrane were detected respectively through setting ten groups from 10 to 100mW/cm2 every other 10 mW/cm2. We found in the study that the ultrasonic transmission coefficient through 0.01 mm PTFE membrane was 78.1% to 92.%, and the ultrasonic transmission coefficient through Bio-Gide collagen membrane was 43.9% to 55.8%. The ultrasonic transmission coefficient through PTFE membrane was obviously higher than that through Bio-Gide collagen membrane. The transmission coefficient of the same barrier membrane of the ultrasonic ion was statistically different under different powers (P PTFE membrane and Bio-Gide collagen membrane were relatively high. We should select barrier membranes based on different experimental needs, and exercise ultrasonic transmission coefficient experiments to ensure effective power.

  14. Comparison of low-intensity pulsed ultrasound and pulsed electromagnetic field treatments on OPG and RANKL expression in human osteoblast-like cells

    NARCIS (Netherlands)

    Borsje, Manon A.; Ren, Yijin; de Haan-Visser, H. Willy; Kuijer, Roel

    OBJECTIVE: To compare two clinically applied treatments to stimulate bone healing-low-intensity pulsed ultrasound (LIPUS) and pulsed electromagnetic field (PEMF)-for their effects on RANKL and OPG expression in osteoblast-like cells in vitro. MATERIALS AND METHODS: LIPUS or PEMF was applied to

  15. Effects of low-intensity pulsed ultrasound on new trabecular bone during bone-tendon junction healing in a rabbit model: a synchrotron radiation micro-CT study.

    Directory of Open Access Journals (Sweden)

    Hongbin Lu

    Full Text Available This study was designed to evaluate the effects of low-intensity pulsed ultrasound on bone regeneration during the bone-tendon junction healing process and to explore the application of synchrotron radiation micro computed tomography in three dimensional visualization of the bone-tendon junction to evaluate the microarchitecture of new trabecular bone. Twenty four mature New Zealand rabbits underwent partial patellectomy to establish a bone-tendon junction injury model at the patella-patellar tendon complex. Animals were then divided into low-intensity pulsed ultrasound treatment (20 min/day, 7 times/week and placebo control groups, and were euthanized at week 8 and 16 postoperatively (n = 6 for each group and time point. The patella-patellar tendon specimens were harvested for radiographic, histological and synchrotron radiation micro computed tomography detection. The area of the newly formed bone in the ultrasound group was significantly greater than that of control group at postoperative week 8 and 16. The high resolution three dimensional visualization images of the bone-tendon junction were acquired by synchrotron radiation micro computed tomography. Low-intensity pulsed ultrasound treatment promoted dense and irregular woven bone formation at week 8 with greater bone volume fraction, number and thickness of new trabecular bone but with lower separation. At week 16, ultrasound group specimens contained mature lamellar bone with higher bone volume fraction and thicker trabeculae than that of control group; however, there was no significant difference in separation and number of the new trabecular bone. This study confirms that low-intensity pulsed ultrasound treatment is able to promote bone formation and remodeling of new trabecular bone during the bone-tendon junction healing process in a rabbit model, and the synchrotron radiation micro computed tomography could be applied for three dimensional visualization to quantitatively evaluate

  16. Low-intensity pulsed ultrasound enhances angiogenesis and ameliorates contractile dysfunction of pressure-overloaded heart in mice.

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Ogata

    Full Text Available Chronic left ventricular (LV pressure overload causes relative ischemia with resultant LV dysfunction. We have recently demonstrated that low-intensity pulsed ultrasound (LIPUS improves myocardial ischemia in a pig model of chronic myocardial ischemia through enhanced myocardial angiogenesis. In the present study, we thus examined whether LIPUS also ameliorates contractile dysfunction in LV pressure-overloaded hearts.Chronic LV pressure overload was induced with transverse aortic constriction (TAC in mice. LIPUS was applied to the whole heart three times in the first week after TAC and was repeated once a week for 7 weeks thereafter (n = 22. Animals in the control groups received the sham treatment without LIPUS (n = 23. At 8 weeks after TAC, LV fractional shortening was depressed in the TAC-Control group, which was significantly ameliorated in the TAC-LIPUS group (30.4±0.5 vs. 36.2±3.8%, P<0.05. Capillary density was higher and perivascular fibrosis was less in the LV in the TAC-LIPUS group than in the TAC-Control group. Myocardial relative ischemia evaluated with hypoxyprobe was noted in the TAC-Control group, which was significantly attenuated in the TAC-LIPUS group. In the TAC-LIPUS group, as compared with the control group, mRNA expressions of BNP and collagen III were significantly lower (both P<0.05 and protein expressions of VEGF and eNOS were significantly up-regulated associated with Akt activation (all P<0.05. No adverse effect related to the LIPUS therapy was noted.These results indicate that the LIPUS therapy ameliorates contractile dysfunction in chronically pressure-overloaded hearts through enhanced myocardial angiogenesis and attenuated perivascular fibrosis. Thus, the LIPUS therapy may be a promising, non-invasive treatment for cardiac dysfunction due to chronic pressure overload.

  17. Effects of Low-Intensity Pulsed Ultrasound on Orthodontic Tooth Movement and Orthodontically Induced Inflammatory Root Resorption in Ovariectomized Osteoporotic Rats.

    Science.gov (United States)

    Dahhas, Feras Y; El-Bialy, Tarek; Afify, Ahmed R; Hassan, Ali H

    2016-03-01

    This study investigated the effects of low-intensity pulsed ultrasound (LIPUS) on orthodontic tooth movement (OTM) and orthodontically induced inflammatory root resorption (OIRR) in ovariectomized osteoporotic rats. Forty-eight 28-d-old female Wistar rats were divided into ovariectomized and intact groups. In both groups, animals were left untreated; treated with 50 g mesially directed orthodontic force on the maxillary first molars using nickel-titanium closed-coil springs for 28 d; or treated with the same orthodontic protocol along with a 20-min LIPUS application on alternate days for 28 d. Extent of OTM and amount of OIRR of mesial roots were measured on three-dimensionally reconstructed micro-computed tomography images. Ovariectomy increased OIRR (p root volumetric loss regardless of ovariectomy status (p < 0.05); only ovariectomized animals had decreased OTM (p < 0.05). LIPUS normalizes OTM and attenuates OIRR in ovariectomized osteoporotic rats. It may therefore be beneficial in women with postmenopausal osteoporosis. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  18. Effect of Nonviral Plasmid Delivered Basic Fibroblast Growth Factor and Low Intensity Pulsed Ultrasound on Mandibular Condylar Growth: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Harmanpreet Kaur

    2014-01-01

    Full Text Available Objective. Basic fibroblast growth factor (bFGF is an important regulator of tissue growth. Previous studies have shown that low intensity pulsed ultrasound (LIPUS stimulates bone growth. The objective of this study was to evaluate the possible synergetic effect of LIPUS and local injection of nonviral bFGF plasmid DNA (pDNA on mandibular growth in rats. Design. Groups were control, blank pDNA, bFGF pDNA, LIPUS, and bFGF pDNA + LIPUS. Treatments were performed for 28 days. Significant increase was observed in mandibular height and condylar length in LIPUS groups. MicroCT analysis showed significant increase in bone volume fraction in bFGF pDNA + LIPUS group. Histomorphometric analysis showed increased cell count and condylar proliferative and hypertrophic layers widths in bFGF pDNA group. Results. Current study showed increased mandibular condylar growth in either bFGF pDNA or LIPUS groups compared to the combined group that showed only increased bone volume fraction. Conclusion. It appears that there is an additive effect of bFGF + LIPUS on the mandibular growth.

  19. Low-Intensity Pulsed Ultrasound Enhances Nerve Growth Factor-Induced Neurite Outgrowth through Mechanotransduction-Mediated ERK1/2-CREB-Trx-1 Signaling.

    Science.gov (United States)

    Zhao, Lu; Feng, Yi; Hu, Hong; Shi, Aiwei; Zhang, Lei; Wan, Mingxi

    2016-12-01

    Enhancing the action of nerve growth factor (NGF) is a potential therapeutic approach to neural regeneration. To facilitate neural regeneration, we investigated whether combining low-intensity pulsed ultrasound (LIPUS) and NGF could promote neurite outgrowth, an essential process in neural regeneration. In the present study, PC12 cells were subjected to a combination of LIPUS (1 MHz, 30 or 50 mW/cm 2 , 20% duty cycle and 100-Hz pulse repetition frequency, 10 min every other day) and NGF (50 ng/mL) treatment, and then neurite outgrowth was compared. Our findings indicated that the combined treatment with LIPUS (50 mW/cm 2 ) and NGF (50 ng/mL) promotes neurite outgrowth that is comparable to that achieved by NGF (100 ng/mL) treatment alone. LIPUS significantly increased NGF-induced neurite length, but not neurite branching. These effects were attributed to the enhancing effects of LIPUS on NGF-induced phosphorylation of ERK1/2 and CREB and the expression of thioredoxin (Trx-1). Furthermore, blockage of stretch-activated ion channels with Gd 3+ suppressed the stimulating effects of LIPUS on NGF-induced neurite outgrowth and the downstream signaling activation. Taken together, our findings suggest that LIPUS enhances NGF-induced neurite outgrowth through mechanotransduction-mediated signaling of the ERK1/2-CREB-Trx-1 pathway. The combination of LIPUS and NGF could potentially be used for the treatment of nerve injury and neurodegenerative diseases. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  20. CO2 bubbling-based 'Nanobomb' System for Targetedly Suppressing Panc-1 Pancreatic Tumor via Low Intensity Ultrasound-activated Inertial Cavitation.

    Science.gov (United States)

    Zhang, Kun; Xu, Huixiong; Chen, Hangrong; Jia, Xiaoqing; Zheng, Shuguang; Cai, Xiaojun; Wang, Ronghui; Mou, Juan; Zheng, Yuanyi; Shi, Jianlin

    2015-01-01

    Noninvasive and targeted physical treatment is still desirable especially for those cancerous patients. Herein, we develop a new physical treatment protocol by employing CO2 bubbling-based 'nanobomb' system consisting of low-intensity ultrasound (1.0 W/cm(2)) and a well-constructed pH/temperature dual-responsive CO2 release system. Depending on the temperature elevation caused by exogenous low-intensity therapeutic ultrasound irradiation and the low pH caused by the endogenous acidic-environment around/within tumor, dual-responsive CO2 release system can quickly release CO2 bubbles, and afterwards, the generated CO2 bubbles waves will timely explode before dissolution due to triggering by therapeutic ultrasound waves. Related bio-effects (e.g., cavitation, mechanical, shock waves, etc) caused by CO2 bubbles' explosion effectively induce instant necrosis of panc-1 cells and blood vessel destruction within panc-1 tumor, and consequently inhibit the growth of panc-1 solid tumor, simultaneously minimizing the side effects to normal organs. This new physiotherapy employing CO2 bubbling-based 'nanobomb' system promises significant potentials in targetedly suppressing tumors, especially for those highly deadly cancers.

  1. 99mTechnetium-methylene diphosphonate bone imaging using low-intensity pulsed ultrasound: promotion of bone formation during mandibular distraction osteogenesis in dogs.

    Science.gov (United States)

    Ding, Yuxiang; Li, Guoquan; Ao, Jianhua; Zhou, Libin; Ma, Qin; Liu, Yanpu

    2010-03-01

    Our objective was to assess the value of (99m)technetium-methylene diphosphonate ((99m)Tc-MDP) bone imaging in the use of low-intensity pulsed ultrasound to promote bony formation during mandibular distraction osteogenesis in dogs. The body of the mandibles in 7 dogs were cut between the first and the second premolar and were lengthened at the rate of 1mm/day, twice a day, for 20 days. During the period of distraction one lateral distraction gap was irradiated with low-intensity pulsed ultrasound (LIPUS) for 10min twice a day, and the other side was used as control. Serial radiographic inspections were made at different periods (0, 1, 2, 4, 6, 8, and 12 weeks) during the consolidation phase, followed by a plain radiograph and histological examination. The (99m)Tc-MDP imaging showed that the ratio of bone formation on the LIPUS-treated side was significantly higher than that on the control side during the early period of consolidation (before the 4th week), but later this was reversed and there were no significant differences between the two sides by the 12th week. Plain radiographs and histological examination showed that the new bone on the experimental side had matured earlier than that on the control side. Radionuclide bone imaging is a good way to assess the formation of bone after distraction osteogenesis.

  2. Evaluation of Low Intensity Pulsed Ultrasound Effects on the Osteogenesis Potential of Demineralized Bone Matrix in Experimental Tibial Defect in Rabbits

    Directory of Open Access Journals (Sweden)

    Ezzati Givi

    2016-09-01

    Full Text Available Background Many studies have assessed the effects of either low intensity pulsed ultrasound (LIPUS or demineralized bone matrix (DBM on bone repair; however, an evaluation of the combination of these modalities (LIPUS + DBM has not yet been considered. Objectives This study aimed to investigate combined effects of DBM and LIPUS on fracture healing. Methods Bilateral 5-mm tibial defects were created in male Dutch rabbits (n = 30. Animals were divided to two groups of empty defect (A and DBM group (B, in which commercial DBM putty was used in defects. In each animal left tibia was treated with LIPUS (intensity = 30 mW/cm2, I SATA, 1 MHz, 20 min/day, pulsed duty 1:4 and the contralateral limb was used as the control. Animals, after 14, 28 and 60 days, were submitted to radiographic or computerized tomography (CT scanning analysis. Results At two weeks, LIPUS had no substantial effect on bone formation. Slight increase of average rates in LIPUS group (A2 were seen compared to the empty defect group (A1 at day 21 and 28. In the DBM–treated group compared with the sham LIPUS, bone-healing rate was reduced at the end of the period (60 days after surgery. The average healing rate in group B at the end of the 60-day period was less than group A after 21 days. Conclusions The present study discusses systemic effect of LIPUS because of non-significant results between treated group and control group and is the first to demonstrate that LIPUS decreases bone formation induced by DBM.

  3. Enhancement of osteogenic differentiation and proliferation in human mesenchymal stem cells by a modified low intensity ultrasound stimulation under simulated microgravity.

    Directory of Open Access Journals (Sweden)

    Sardar M Z Uddin

    Full Text Available Adult stem cells can differentiate into multiple lineages depending on their exposure to differing biochemical and biomechanical inductive factors. Lack of mechanical signals due to disuse can inhibit osteogenesis and induce adipogenesis of mesenchymal stem cells (MSCs. Long-term bed rest due to both brain/spinal cord injury and space travel can lead to disuse osteoporosis that is in part caused by a reduced number of osteoblasts. Thus, it is essential to provide proper mechanical stimulation for cellular viability and osteogenesis, particularly under disuse conditions. The objective of this study was to examine the effects of low intensity pulsed ultrasound (LIPUS on the osteogenic differentiation of adipose-derived human stem cells (Ad-hMSC in simulated microgravity conditions. Cells were cultured in a 1D clinostat to simulate microgravity (SMG and treated with LIPUS at 30mW/cm(2 for 20 min/day. It was hypothesized that the application of LIPUS to SMG cultures would restore osteogenesis in Ad-hMSCs. The results showed significant increases in ALP, OSX, RANKL, RUNX2, and decreases in OPG in LIPUS treated SMG cultures of Ad-MSC compared to non-treated cultures. LIPUS also restored OSX, RUNX2 and RANKL expression in osteoblast cells. SMG significantly reduced ALP positive cells by 70% (p<0.01 and ALP activity by 22% (p<0.01, while LIPUS treatment restored ALP positive cell number and activity to equivalence with normal gravity controls. Extracellular matrix collagen and mineralization was assessed by Sirius red and Alizarin red staining, respectively. SMG cultures showed little or no collagen or mineralization, but LIPUS treatment restored collagen content to 50% (p<0.001 and mineralization by 45% (p<0.001 in LIPUS treated-SMG cultures relative to SMG-only cultures. The data suggest that LIPUS treatment can restore normal osteogenic differentiation of MSCs from disuse by daily short duration stimulation.

  4. Recombinant human parathyroid hormone (PTH 1-34) and low-intensity pulsed ultrasound have contrasting additive effects during fracture healing.

    Science.gov (United States)

    Warden, Stuart J; Komatsu, David E; Rydberg, Johanna; Bond, Julie L; Hassett, Sean M

    2009-03-01

    Fracture healing is thought to be naturally optimized; however, recent evidence indicates that it may be manipulated to occur at a faster rate. This has implications for the duration of morbidity associated with bone injuries. Two interventions found to accelerate fracture healing processes are recombinant human parathyroid hormone [1-34] (PTH) and low-intensity pulsed ultrasound (LIPUS). This study aimed to investigate the individual and combined effects of PTH and LIPUS on fracture healing. Bilateral midshaft femur fractures were created in Sprague-Dawley rats, and the animals treated 7 days/week with PTH (10 microg/kg) or a vehicle solution. Each animal also had one fracture treated for 20 min/day with active-LIPUS (spatial-averaged, temporal-averaged intensity [I(SATA)]=100 mW/cm(2)) and the contralateral fracture treated with inactive-LIPUS (placebo). Femurs were harvested 35 days following injury to permit micro-computed tomography, mechanical property and histological assessments of the fracture calluses. There were no interactions between PTH and LIPUS indicating that their effects were additive rather than synergistic. These additive effects were contrasting with LIPUS primarily increasing total callus volume (TV) without influencing bone mineral content (BMC), and PTH having the opposite effect of increasing BMC without influencing TV. As a consequence of the effect of LIPUS on TV but not BMC, it decreased volumetric bone mineral density (vBMD) resulting in a less mature callus. The decreased maturity and persistence of cartilage at the fracture site when harvested offset any beneficial mechanical effects of the increased callus size with LIPUS. In contrast, the effect of PTH on callus BMC but not TV resulted in increased callus vBMD and a more mature callus. This resulted in PTH increasing fracture site mechanical strength and stiffness. These data suggest that PTH may have utility in the treatment of acute bone fractures, whereas LIPUS at an I(SATA) of

  5. Combination of doxorubicin and low-intensity ultrasound causes a synergistic enhancement in cell killing and an additive enhancement in apoptosis induction in human lymphoma U937 cells.

    Science.gov (United States)

    Yoshida, Toru; Kondo, Takashi; Ogawa, Ryohei; Feril, Loreto B; Zhao, Qing-Li; Watanabe, Akihiko; Tsukada, Kazuhiro

    2008-04-01

    Potential clinical use of ultrasound (US) in enhancing the effects of anticancer drugs in the treatment of cancers has been highlighted in previous reports. Increased uptake of drugs by the cancer cells due to US has been suggested as a mechanism. However, the precise mechanism of the enhancement has not yet been elucidated. Here, the combined effects of low-intensity pulsed US and doxorubicin (DOX) on cell killing and apoptosis induction of U937 cells, and mechanisms involved were investigated. Human myelomonocytic lymphoma U937 cells were used for the experiments. Experiments were conducted in 4 groups: (1) non-treated, (2) DOX treated (DOX), (3) US treated (US), and (4) combined (DOX + US). In DOX +US, cells were exposed to 5 microM DOX for 30 min and sonicated by 1 MHz pulsed US (PRF 100 Hz, DF 10%) at intensities of 0.2-0.5 W/cm(2) for 60 s. The cells were washed and incubated for 6 h. The viability was evaluated by Trypan blue dye exclusion test and apoptosis and incorporation of DOX was assessed by flow cytometry. Involvement of sonoporation in molecular incorporation was evaluated using FITC-dextran, hydroxyl radical formation was measured by electron paramagnetic resonance-spin trapping, membrane alteration including lipid peroxidation and membrane fluidity by DOX was evaluated using cis-parinaric acid and perylene fluorescence polarization method, respectively. Synergistic enhancement in cell killing and additive enhancement in induction of apoptosis were observed at and above 0.3 W/cm(2). No enhancement was observed at 0.2 W/cm(2) in cell killing and induction of apoptosis. Hydroxyl radicals formation was detected at and above 0.3 W/cm(2). The radicals were produced more in the DOX + US than US alone. Incorporation of DOX was increased 13% in DOX + US (vs. DOX) at 0.5 W/cm(2). Involvement of sonoporation for increase of drug uptake was suggested by experiment using FITC-labeled dextran. We made the hypothesis that DOX treatment made the cells weaken

  6. Low-intensity training increases peak arm VO2 by enhancing both convective and diffusive O2 delivery

    DEFF Research Database (Denmark)

    Boushel, R; Ara, I; Gnaiger, E

    2014-01-01

    in prolonged low-intensity training of a small muscle group when the cardiac output capacity is not directly limiting. The purpose of this study was to investigate the relative roles of circulatory and muscle metabolic mechanisms by which prolonged low-intensity exercise training alters regional muscle VO2 ....

  7. Low-intensity pulsed ultrasound (LIPUS) stimulates mineralization of MC3T3-E1 cells through calcium and phosphate uptake.

    Science.gov (United States)

    Tassinary, João Alberto Fioravante; Lunardelli, Adroaldo; Basso, Bruno de Souza; Dias, Henrique Bregolin; Catarina, Anderson Velasque; Stülp, Simone; Haute, Gabriela Viegas; Martha, Bianca Andrade; Melo, Denizar Alberto da Silva; Nunes, Fernanda Bordignon; Donadio, Márcio Vinícius Fagundes; Oliveira, Jarbas Rodrigues de

    2018-03-01

    The present study aimed to evaluate the effect of low-intensity pulsed ultrasound (LIPUS) on pre-osteoblast mineralization using in vitro bioassays. Pre-osteoblastic MC3T3-E1 cells were exposed to LIPUS at 1 MHz frequency, 0.2 W/cm 2 intensity and 20% duty cycle for 30 min. The analyses were carried out up to 336 h (14 days) after exposure. The concentration of collagen, phosphate, alkaline phosphatase, calcium and transforming growth factor beta 1 (TGF-β1) in cell supernatant and the presence of calcium deposits in the cells were analyzed. Our results showed that LIPUS promotes mineralized nodules formation. Collagen, phosphate, and calcium levels were decreased in cell supernatant at 192 h after LIPUS exposure. However, alkaline phosphatase and TGF-β1 concentrations remained unchanged. Therapeutic pulsed ultrasound is capable of stimulating differentiation and mineralization of pre-osteoblastic MC3T3-E1 cells by calcium and phosphate uptake with consequent hydroxyapatite formation. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Estimation of the distribution of low-intensity ultrasound mechanical index as a parameter affecting the proliferation of spermatogonia stem cells in vitro.

    Science.gov (United States)

    Moghaddam, Zeinab Hormozi; Mokhtari-Dizaji, Manijhe; Movahedin, Mansoureh; Ravari, Mohammad Ehsan

    2017-07-01

    Considering the use of physical and mechanical stimulation, such as low-intensity ultrasound for proliferation and differentiation of stem cells, it is essential to understand the physical and acoustical mechanisms of acoustic waves in vitro. Mechanical index is used for quantifying acoustic cavitation and the relationship between acoustic pressure and the frequency. In this study, modeling of the mechanical index was applied to provide treatment protocol and to understand the effective physical processes on reproducibility of stem cells. Due to low intensity of ultrasound, Rayleigh integral model has been used for acoustic pressure computation. The acoustic pressure and mechanical index equations are modeled and solved to estimate optimal mechanical index for 28, 40, 150kHz and 1MHz frequencies. This model are solved in different intensities and distances from transducer in cylindrical coordinates. Based on the results of the mechanical index, regions with threshold mechanical index of 0.7 were identified for extracting of radiation arrangement to cell medium. Acoustic pressure distribution along the axial and radial was extracted. In order to validate the results of the modeling, the acoustic pressure in the water and near field depth was measured by a piston hydrophone. Results of modeling and experiments show that the model is consistent well to experimental results with 0.91 and 0.90 correlation of coefficient (pmechanical index is more effective on enhancing the proliferation rate of the spermatogonia stem cells during the seven days of culture. In contrast, higher mechanical index has a harmful effect on the spermatogonial stem cells. Thus, considering cavitation threshold of different materials is necessary to find effective mechanical index ranges on proliferation for the used frequencies. This acoustic propagation model and ultrasound mechanical index assessments can be used with acceptable accuracy, for the extraction special arrangement of acoustic

  9. Optimization of low-frequency low-intensity ultrasound-mediated microvessel disruption on prostate cancer xenografts in nude mice using an orthogonal experimental design.

    Science.gov (United States)

    Yang, Y U; Bai, Wenkun; Chen, Yini; Lin, Yanduan; Hu, Bing

    2015-11-01

    The present study aimed to provide a complete exploration of the effect of sound intensity, frequency, duty cycle, microbubble volume and irradiation time on low-frequency low-intensity ultrasound (US)-mediated microvessel disruption, and to identify an optimal combination of the five factors that maximize the blockage effect. An orthogonal experimental design approach was used. Enhanced US imaging and acoustic quantification were performed to assess tumor blood perfusion. In the confirmatory test, in addition to acoustic quantification, the specimens of the tumor were stained with hematoxylin and eosin and observed using light microscopy. The results revealed that sound intensity, frequency, duty cycle, microbubble volume and irradiation time had a significant effect on the average peak intensity (API). The extent of the impact of the variables on the API was in the following order: Sound intensity; frequency; duty cycle; microbubble volume; and irradiation time. The optimum conditions were found to be as follows: Sound intensity, 1.00 W/cm 2 ; frequency, 20 Hz; duty cycle, 40%; microbubble volume, 0.20 ml; and irradiation time, 3 min. In the confirmatory test, the API was 19.97±2.66 immediately subsequent to treatment, and histological examination revealed signs of tumor blood vessel injury in the optimum parameter combination group. In conclusion, the Taguchi L 18 (3) 6 orthogonal array design was successfully applied for determining the optimal parameter combination of API following treatment. Under the optimum orthogonal design condition, a minimum API of 19.97±2.66 subsequent to low-frequency and low-intensity mediated blood perfusion blockage was obtained.

  10. Improved healing response in delayed unions of the tibia with low-intensity pulsed ultrasound: results of a randomized sham-controlled trial

    Directory of Open Access Journals (Sweden)

    Aigner Julia

    2010-10-01

    Full Text Available Abstract Background We compared the healing response of tibial delayed unions between subjects treated with low-intensity pulsed ultrasound (LIPUS (n = 51 and subjects treated with a sham device (n = 50. Fracture age was ≥ 4 months in all cases. Study personnel and participants were blinded to random treatment assignment throughout the study. Methods This multi-center randomized sham-controlled trial was undertaken at six hospitals in Germany. Adult patients who had sustained a tibial shaft fracture that subsequently showed inadequate progress toward healing (i.e., delayed union were enrolled and randomized to receive either LIPUS (Exogen 2000/2000+, Smith & Nephew GmbH, Schenefeld, Germany or an identical nonoperative sham device. The daily treatment duration was 20 minutes, for a period of 16 weeks. Subjects randomly assigned to active treatment had the ultrasound pressure wave signal set at the following parameters: 1.5 MHz frequency, 1 kHz repetition rate, 200 μs pulse duration, 30 mW/cm2 spatial intensity. Progress toward healing was estimated from changes in bone mineral density (BMD and gap area as determined from computed tomography scans. Intention-to-treat analysis was conducted using a multiple imputation methodology. Results Based on log-transformed data, mean improvement in BMD was 1.34 (90% confidence interval (CI 1.14 to 1.57 times greater for LIPUS-treated subjects compared to sham (p = 0.002. A mean reduction in bone gap area also favored LIPUS treatment (p = 0.014. Conclusions These findings demonstrate significantly greater progress toward bone healing after LIPUS treatment compared to no LIPUS treatment in subjects with established delayed unions of the tibia.

  11. Low-intensity pulsed ultrasound stimulates cell proliferation, proteoglycan synthesis and expression of growth factor-related genes in human nucleus pulposus cell line

    Directory of Open Access Journals (Sweden)

    Y Kobayashi

    2009-06-01

    Full Text Available Low-intensity pulsed ultrasound (LIPUS stimulation has been shown to effect differentiation and activation of human chondrocytes. A study involving stimulation of rabbit disc cells with LIPUS revealed upregulation of cell proliferation and proteoglycan (PG synthesis. However, the effect of LIPUS on human nucleus pulposus cells has not been investigated. In the present study, therefore, we investigated whether LIPUS stimulation of a human nucleus pulposus cell line (HNPSV-1 exerted a positive effect on cellular activity. HNPSV-1 cells were encapsulated in 1.2% sodium alginate solution at 1x105 cells/ml and cultured at 10 beads/well in 6-well plates. The cells were stimulated for 20 min each day using a LIPUS generator, and the effects of LIPUS were evaluated by measuring DNA and PG synthesis. Furthermore, mRNA expression was analyzed by cDNA microarray using total RNA extracted from the cultured cells. Our study revealed no significant difference in cell proliferation between the control and the ultrasound treated groups. However, PG production was significantly upregulated in HNPSV cells stimulated at intensities of 15, 30, 60, and 120 mW/cm2 compared with the control. The results of cDNA array showed that LIPUS significantly stimulated the gene expression of growth factors and their receptors (BMP2, FGF7, TGFbetaR1 EGFRF1, VEGF. These findings suggest that LIPUS stimulation upregulates PG production in human nucleus pulposus cells by the enhancement of several matrix-related genes including growth factor-related genes. Safe and non-invasive stimulation using LIPUS may be a useful treatment for delaying the progression of disc degeneration.

  12. [Histomorphological analyse of accelerating the fibrocartilage layer repair of patella-patellar tendon junction in rabbits by low intensity pulsed ultrasound stimulation].

    Science.gov (United States)

    Zhang, Baoliang; Lü, Hongbin; Hu, Jianzhong; Xu, Daqi; Zhou, Jingyong; Wang, Ye

    2013-08-01

    To analyse the effect of low intensity pulsed ultrasound stimulation (LIPUS) on accelerating the fibrocartilage layer repair of patella-patellar tendon junction. A total of 60 mature female New Zealand white rabbits undergoing standard partial patellectomy were divided into 2 groups randomly. The control group was given comfort treatment and the treatment group was given LIPUS treatment starting from day 3 to the end of week 6 postoperatively. The scheduled time points of animal euthanization would be at week 6, week 12 and week 18 postoperatively. The patella-patellar tendon (PPT) complex would be harvested and cut into sections after decalcification for H&E staining, Safranine o/fast green staining. The thickness and gray value of fibrocartilage layer were analyzed by SANO Microscope Partner image analyzer. At week 6, week 12 and week 18 postoperatively, the fibrocartilage layer in the treatment group was significantly thicker than that in the control group (Pfibrocartilage layer was significantly smaller than that in the control group (Pfibrocartilage layer repair of patella-patellar tendon junction in rabbit models.

  13. Efeitos do ultra-som de baixa intensidade na veia auricular de coelhos Effects of low intensity ultrasound in the auricular vein of rabbits

    Directory of Open Access Journals (Sweden)

    Marcelo Araújo

    2003-01-01

    Full Text Available OBJETIVO: Estudar a ação do ultra-som na veia auricular de coelhos. MÉTODOS: Vinte coelhos foram divididos em dois grupos de dez animais diferindo com relação ao local da aplicação, do ultra-som, o modo e o intervalo de tempo para a análise histopatológica (3 e 7 dias. Os animais foram submetidos à aplicação de ultra-som contínuo e pulsado em dois segmentos venosos da orelha previamente determinados. Cada animal foi o seu próprio controle. Empregou-se a freqüência de 3MHz, intensidade de 3W/cm² nos ciclos pulsado e contínuo por 10 minutos, de forma estacionária. O grupo I foi submetido a eutanásia após 3 dias e o grupo II em 7 dias contemplando a fase aguda do processo inflamatório. Empregou-se o teste exato de Fisher e o teste de Mc Nemar para análise estatística. RESULTADOS: Obteve-se trombose venosa e aumento de linfócitos de forma significativa (p= 0,032 nos grupos tratados com o modo contínuo. O modo pulsado não provocou efeitos deletérios. Outros achados foram congestão, edema, hemorragia e lesão da parede vascular. CONCLUSÕES: O ultra-som pulsado não provoca qualquer alteração na parede vascular nas condições do experimento.O ultra-som contínuo induz a trombose venosa e aumento dos linfócitos de forma significativa.PURPOSE: The purpose of this experimental work was evaluate the effects of low intensity in the auricular vein of rabbits. METHODS: Twenty rabbits were divided in two groups of ten animals. The groups differed about the place where the continuous and pulsed ultrasound were applied and the period that the material was collected for the morphologic examination (3 and 7 days. Acoustic coupling gel was used on marginal ear vein, each animal underwent continuous and pulsed ultrasound treatment, in segments previously marked with indelible ink. Each animal provided its own control. Ultrasound was used in the frequency of 3MHz, intensity of 3W/cm² in the pulsed and continuous modes during 10min

  14. Gene expression profiling analysis of the effects of low-intensity pulsed ultrasound on induced pluripotent stem cell-derived neural crest stem cells.

    Science.gov (United States)

    Xia, Bin; Zou, Yang; Xu, Zhiling; Lv, Yonggang

    2017-11-01

    Low-intensity pulsed ultrasound (LIPUS) is a noninvasive technique that has been shown to affect cell proliferation, migration, and differentiation and promote the regeneration of damaged peripheral nerve. Our previous studies had proved that LIPUS can significantly promote the neural differentiation of induced pluripotent stem cell-derived neural crest stem cells (iPSCs-NCSCs) and enhance the repair of rat-transected sciatic nerve. To further explore the underlying mechanisms of LIPUS treatment of iPSCs-NCSCs, this study reported the gene expression profiling analysis of iPSCs-NCSCs before and after LIPUS treatment using the RNA-sequencing (RNA-Seq) method. It was found that expression of 76 genes of iPSCs-NCSCs cultured in a serum-free neural induction medium and expression of 21 genes of iPSCs-NCSCs cultured in a neuronal differentiation medium were significantly changed by LIPUS treatment. The differentially expressed genes are related to angiogenesis, nervous system activity and functions, cell activities, and so on. The RNA-seq results were further verified by a quantitative real-time reverse transcriptase polymerase chain reaction (qRT-PCR). High correlation was observed between the results obtained from qRT-PCR and RNA-Seq. This study presented new information on the global gene expression patterns of iPSCs-NCSCs after LIPUS treatment and may expand the understanding of the complex molecular mechanism of LIPUS treatment of iPSCs-NCSCs. © 2017 International Union of Biochemistry and Molecular Biology, Inc.

  15. Low intensity ultrasound promotes the sensitivity of rat brain glioma to Doxorubicin by down-regulating the expressions of p-glucoprotein and multidrug resistance protein 1 in vitro and in vivo.

    Directory of Open Access Journals (Sweden)

    Zhen Zhang

    Full Text Available The overall prognosis for malignant glioma is extremely poor, and treatment options are limited in part because of multidrug resistant proteins. Our previous findings suggest low intensity ultrasound (LIUS can induce apoptosis of glioma cells. Given this finding, we were interested in determining if LIUS could help treat glioma by inhibiting multidrug resistant proteins, and if so, which pathways are involved. In this study, the toxicity sensitivity and multidrug resistance proteins of glioma induced by LIUS were investigated using CCK-8, immunohistochemistry, immunofluorency, and RT-PCR in tissue samples and cultured cells. LIUS inhibited increase of C6 cells in an intensity- and time-dependent manner. The toxicity sensitivity of C6 cells increased significantly after LIUS sonication (intensity of 142.0 mW/cm(2 or Doxorubicin (DOX at different concentration, particularly by the combination of LIUS sonication and DOX. The expressions of P-gp and MRP1 decreased significantly post-sonication at intensity of 142.0 mW/cm(2 both in vitro and in vivo. The expressions of p110 delta (PI3K, NF-κB-p65, Akt/PKB, and p-Akt/PKB were downregulated by LIUS sonication and DOX treatment separately or in combination at the same parameters in rat glioma. These results indicate that LIUS could increase the toxicity sensitivity of glioma by down-regulating the expressions of P-gp and MRP1, which might be mediated by the PI3K/Akt/NF-κB pathway.

  16. Low-intensity repetitive magnetic stimulation lowers action potential threshold and increases spike firing in layer 5 pyramidal neurons in vitro.

    Science.gov (United States)

    Tang, Alexander D; Hong, Ivan; Boddington, Laura J; Garrett, Andrew R; Etherington, Sarah; Reynolds, John N J; Rodger, Jennifer

    2016-10-29

    Repetitive transcranial magnetic stimulation (rTMS) has become a popular method of modulating neural plasticity in humans. Clinically, rTMS is delivered at high intensities to modulate neuronal excitability. While the high-intensity magnetic field can be targeted to stimulate specific cortical regions, areas adjacent to the targeted area receive stimulation at a lower intensity and may contribute to the overall plasticity induced by rTMS. We have previously shown that low-intensity rTMS induces molecular and structural plasticity in vivo, but the effects on membrane properties and neural excitability have not been investigated. Here we investigated the acute effect of low-intensity repetitive magnetic stimulation (LI-rMS) on neuronal excitability and potential changes on the passive and active electrophysiological properties of layer 5 pyramidal neurons in vitro. Whole-cell current clamp recordings were made at baseline prior to subthreshold LI-rMS (600 pulses of iTBS, n=9 cells from 7 animals) or sham (n=10 cells from 9 animals), immediately after stimulation, as well as 10 and 20min post-stimulation. Our results show that LI-rMS does not alter passive membrane properties (resting membrane potential and input resistance) but hyperpolarises action potential threshold and increases evoked spike-firing frequency. Increases in spike firing frequency were present throughout the 20min post-stimulation whereas action potential (AP) threshold hyperpolarization was present immediately after stimulation and at 20min post-stimulation. These results provide evidence that LI-rMS alters neuronal excitability of excitatory neurons. We suggest that regions outside the targeted region of high-intensity rTMS are susceptible to neuromodulation and may contribute to rTMS-induced plasticity. Copyright © 2016 IBRO. All rights reserved.

  17. Increasing vaccine production using pulsed ultrasound waves.

    Directory of Open Access Journals (Sweden)

    Jida Xing

    Full Text Available Vaccination is a safe and effective approach to prevent deadly diseases. To increase vaccine production, we propose that a mechanical stimulation can enhance protein production. In order to prove this hypothesis, Sf9 insect cells were used to evaluate the increase in the expression of a fusion protein from hepatitis B virus (HBV S1/S2. We discovered that the ultrasound stimulation at a frequency of 1.5 MHz, intensity of 60 mW/cm2, for a duration of 10 minutes per day increased HBV S1/S2 by 27%. We further derived a model for transport through a cell membrane under the effect of ultrasound waves, tested the key assumptions of the model through a molecular dynamics simulation package, NAMD (Nanoscale Molecular Dynamics program and utilized CHARMM force field in a steered molecular dynamics environment. The results show that ultrasound waves can increase cell permeability, which, in turn, can enhance nutrient / waste exchange thus leading to enhanced vaccine production. This finding is very meaningful in either shortening vaccine production time, or increasing the yield of proteins for use as vaccines.

  18. Ultra-som pulsado de baixa intensidade em fraturas diafisárias: aplicação clínica em cães Low-intensity pulsed ultrasound in diaphyseal fractures: clinical application in dogs

    Directory of Open Access Journals (Sweden)

    Valéria Lima de Sousa

    2008-08-01

    Full Text Available Os efeitos da estimulação ultra-sônica sobre a consolidação óssea têm sido demonstrados por trabalhos experimentais e clínicos. Este estudo teve por objetivo investigar a aplicação clínica do ultra-som pulsado de baixa intensidade como tratamento adjuvante de fraturas diafisárias em cães. Foram utilizados 16 cães de raças variadas, com faixa etária entre sete meses e seis anos, peso corpóreo entre 2,5 e 43kg, portadores de fraturas diafisárias fechadas recentes localizadas no rádio e ulna, fêmur ou tíbia e fíbula, estabilizadas por procedimentos de osteossíntese (fixação esquelética externa, pinos intramedulares ou a associação desses métodos. Os cães foram divididos em dois grupos: fraturas estabilizadas tratadas por ultra-som de baixa intensidade (grupo tratado, n=8; fraturas estabilizadas, não tratadas por estimulação ultra-sônica, (grupo controle, n=8. Os animais foram avaliados por exames clínicos e radiográficos nos períodos pré-operatório, pós-operatório imediato e a cada 30 dias posteriores aos procedimentos cirúrgicos. Realizou-se tratamento com ultra-som pulsado (sinal senoidal com freqüência de 1,5MHz, largura de pulso de 200µs e freqüência de repetição de 1kHz de baixa intensidade (30mW cm-2, aplicado de modo estacionário no foco de fratura. A terapia ultra-sônica foi realizada 20 minutos por dia, durante 21 dias consecutivos, a partir do período compreendido entre o 1° e o 9° dia pós-operatório. O teste t de Student, empregado na análise estatística, mostrou diferença significante (PThe effects of ultrasound stimulation on bone healing have been demonstrated in experimental and clinical studies. The purpose of this study was to investigate the clinical application of low-intensity pulsed ultrasound as an adjuvant for the treatment of diaphyseal fractures in dogs. Sixteen dogs of different breeds, ages ranging from seven months to six years, weighing from 2.5 to 43kg, were

  19. Effects of combined therapy of alendronate and low-intensity pulsed ultrasound on metaphyseal bone repair after osteotomy in the proximal tibia of glucocorticoid-induced osteopenia rats

    Directory of Open Access Journals (Sweden)

    Tetsuya Kawano

    2017-12-01

    Conclusions: ALN monotherapy and combined ALN and LUPUS treatment augmented BMD and stimulated cancellous bone repair with increased Runx2 expression at the osteotomy site in GIO rats. However, the combined treatment had no additional effect on cancellous bone healing compared to ALN monotherapy.

  20. Low-Intensity Ultrasound-Induced Anti-inflammatory Effects Are Mediated by Several New Mechanisms Including Gene Induction, Immunosuppressor Cell Promotion, and Enhancement of Exosome Biogenesis and Docking

    Directory of Open Access Journals (Sweden)

    Qian Yang

    2017-10-01

    Full Text Available Background: Low-intensity ultrasound (LIUS was shown to be beneficial in mitigating inflammation and facilitating tissue repair in various pathologies. Determination of the molecular mechanisms underlying the anti-inflammatory effects of LIUS allows to optimize this technique as a therapy for the treatment of malignancies and aseptic inflammatory disorders.Methods: We conducted cutting-edge database mining approaches to determine the anti-inflammatory mechanisms exerted by LIUS.Results: Our data revealed following interesting findings: (1 LIUS anti-inflammatory effects are mediated by upregulating anti-inflammatory gene expression; (2 LIUS induces the upregulation of the markers and master regulators of immunosuppressor cells including MDSCs (myeloid-derived suppressor cells, MSCs (mesenchymal stem cells, B1-B cells and Treg (regulatory T cells; (3 LIUS not only can be used as a therapeutic approach to deliver drugs packed in various structures such as nanobeads, nanospheres, polymer microspheres, and lipidosomes, but also can make use of natural membrane vesicles as small as exosomes derived from immunosuppressor cells as a novel mechanism to fulfill its anti-inflammatory effects; (4 LIUS upregulates the expression of extracellular vesicle/exosome biogenesis mediators and docking mediators; (5 Exosome-carried anti-inflammatory cytokines and anti-inflammatory microRNAs inhibit inflammation of target cells via multiple shared and specific pathways, suggesting exosome-mediated anti-inflammatory effect of LIUS feasible; and (6 LIUS-mediated physical effects on tissues may activate specific cellular sensors that activate downstream transcription factors and signaling pathways.Conclusions: Our results have provided novel insights into the mechanisms underlying anti-inflammatory effects of LIUS, and have provided guidance for the development of future novel therapeutic LIUS for cancers, inflammatory disorders, tissue regeneration and tissue repair.

  1. Low intensity shear stress increases endothelial ELR+ CXC chemokine production via a focal adhesion kinase-p38{beta} MAPK-NF-{kappa}B pathway.

    Science.gov (United States)

    Shaik, Sadiq S; Soltau, Thomas D; Chaturvedi, Gaurav; Totapally, Balagangadhar; Hagood, James S; Andrews, William W; Athar, Mohammad; Voitenok, Nikolai N; Killingsworth, Cheryl R; Patel, Rakesh P; Fallon, Michael B; Maheshwari, Akhil

    2009-02-27

    CXC chemokines with a glutamate-leucine-arginine (ELR) tripeptide motif (ELR(+) CXC chemokines) play an important role in leukocyte trafficking into the tissues. For reasons that are not well elucidated, circulating leukocytes are recruited into the tissues mainly in small vessels such as capillaries and venules. Because ELR(+) CXC chemokines are important mediators of endothelial-leukocyte interaction, we compared chemokine expression by microvascular and aortic endothelium to investigate whether differences in chemokine expression by various endothelial types could, at least partially, explain the microvascular localization of endothelial-leukocyte interaction. Both in vitro and in vivo models indicate that ELR(+) CXC chemokine expression is higher in microvascular endothelium than in aortic endothelial cells. These differences can be explained on the basis of the preferential activation of endothelial chemokine production by low intensity shear stress. Low shear activated endothelial ELR(+) CXC chemokine production via cell surface heparan sulfates, beta(3)-integrins, focal adhesion kinase, the mitogen-activated protein kinase p38beta, mitogen- and stress-associated protein kinase-1, and the transcription factor.

  2. Low intensity transcranial electric stimulation

    DEFF Research Database (Denmark)

    Antal, Andrea; Alekseichuk, I; Bikson, M

    2017-01-01

    Low intensity transcranial electrical stimulation (TES) in humans, encompassing transcranial direct current (tDCS), transcutaneous spinal Direct Current Stimulation (tsDCS), transcranial alternating current (tACS), and transcranial random noise (tRNS) stimulation or their combinations, appears...

  3. Increased detection of schistosomiasis with Kato-Katz and SWAP-IgG-ELISA in a Northeastern Brazil low-intensity transmission area

    Directory of Open Access Journals (Sweden)

    Teiliane Rodrigues Carneiro

    2012-08-01

    Full Text Available INTRODUCTION: The laboratory diagnosis of schistosomiasis is based mainly on the detection of parasite eggs in stool samples through the Kato-Katz (KK technique, reading one slide by test. However, a widely known limitation of parasitological methods is reduced sensitivity, particularly in low endemic areas. METHODS: To increase sensitivity, we conducted further slide readings from the same stool sample using the parasitological method associated with a serological test. We used the KK method (three slides and the IgG anti-Schistosoma mansoni-enzyme-linked immunosorbent assay (ELISA technique to diagnose schistosomiasis in low endemic areas in the Brazilian State of Ceará. Fecal samples and sera from 250 individuals were analyzed. RESULTS: Sixteen percent and 47.2% of samples were positive in parasitological tests and serological tests, respectively. Parasitological methods showed that 32 (80% individuals tested positive on the first slide, 6 (15% on the second slide, and 2 (5% on the third. The performance of the ELISA test in the diagnosis, using the KK method as diagnostic reference, showed a negative predictive value of 100%, with specificity and positive predictive values of 62.8% and 33.9%, respectively. CONCLUSIONS: In this study, the increase from one to three slides analyzed per sample using the KK technique was shown to be a useful procedure for increasing the diagnostic sensitivity of this technique.

  4. High-frequency, low-intensity vibrations increase bone mass and muscle strength in upper limbs, improving autonomy in disabled children.

    Science.gov (United States)

    Reyes, M Loreto; Hernández, Marta; Holmgren, Luz J; Sanhueza, Enrique; Escobar, Raúl G

    2011-08-01

    Disuse osteoporosis in children is a progressive disease that can affect quality of life. High-frequency, low-magnitude vibration (HFLMV) acts as an anabolic signal for bone and muscle. We undertook a prospective, randomized, double-blind, placebo-controlled clinical trial to assess the efficacy and safety of regional HFLMV in disabled children. Sixty-five children 6 to 9 year of age were randomized into three groups: placebo, 60 Hz, and 90 Hz. In the two active groups, a 0.3-g mechanical vibration was delivered to the radii and femurs for 5 minutes each day. After 6 months, the main endpoint was bone mineral density (BMD) at the ultradistal radius (UDR), 33% radii (33%R), and femoral necks (FN). Secondary endpoints were area and bone mineral content (BMC) at the UDR, 33%R, and FN; grip force of the upper and lower limbs; motor function; and PedsQL evaluation. An intention-to-treat analysis was used. Fifty-seven children (88%) completed the protocol. A significant increase was observed in the 60-Hz group relative to the other groups in BMD at the UDR (p = .011), in grip force of the upper limbs (p = .035), and in the "daily activities item" (p = .035). A mixed model to evaluate the response to intervention showed a stronger effect of 60 Hz on patients with cerebral palsy on the UDR and that between-subject variability significantly affected the response. There were no reported side effects of the intervention. This work provides evidence that regional HFLMV is an effective and safe strategy to improve bone mass, muscle strength, and possibly independence in children with motor disabilities. Copyright © 2011 American Society for Bone and Mineral Research.

  5. Indirect Low-Intensity Ultrasonic Stimulation for Tissue Engineering

    Directory of Open Access Journals (Sweden)

    Hyoungshin Park

    2010-01-01

    Full Text Available Low-intensity ultrasound (LIUS treatment has been shown to increase mass transport, which could benefit tissue grafts during the immediate postimplant period, when blood supply to the implanted tissue is suboptimal. In this in vitro study, we investigated effects of LIUS stimulation on dye diffusion, proliferation, metabolism, and tropomyosin expression of muscle cells (C2C12 and on tissue viability and gene expression of human adipose tissue organoids. We found that LIUS increased dye diffusion within adjacent tissue culture wells and caused anisotropic diffusion patterns. This effect was confirmed by a hydrophone measurement resulting in acoustic pressure 150–341 Pa in wells. Cellular studies showed that LIUS significantly increased proliferation, metabolic activity, and expression of tropomyosin. Adipose tissue treated with LIUS showed significantly increased metabolic activity and the cells had similar morphology to normal unilocular adipocytes. Gene analysis showed that tumor necrosis factor-alpha expression (a marker for tissue damage was significantly lower for stimulated organoids than for control groups. Our data suggests that LIUS could be a useful modality for improving graft survival in vivo.

  6. Low-intensity conflict in multinational corporations

    DEFF Research Database (Denmark)

    Lauring, Jakob; Andersen, Poul Houman; Storgaard, Marianne

    2017-01-01

    in four Danish MNCs. Findings: They describe consequences of low-intensity conflict and identify three types of actions by headquarters’ representatives that could lead to the development of low-intensity conflicts, namely, ignoring, bypassing and educating. Originality/value: Very few studies have dealt......Purpose: This paper aims to identify antecedents for, and consequences of, low-intensity inter-unit conflict in multinational corporations (MNCs). Inter-unit conflict in MNCs is an important and well-researched theme. However, while most studies have focused on open conflict acknowledged by both...... parties, much less research has dealt with low-intensity conflicts. Still, low-intensity conflicts can be highly damaging – not least because they are rarely resolved. Design/methodology/approach: The authors used a qualitative approach to understanding low-intensity conflict relying on 170 interviews...

  7. Therapeutic Ultrasound Examination of Follicular Reserve, and Ovarian Tissue Angiogenesis in Mice, 14 Days after Heterotopic Transplantation

    Directory of Open Access Journals (Sweden)

    N Abtahi

    2014-06-01

    Results: The study results showed that the CD31 angiogenic factor was expressed more in the irradiated animals than in control group animals and ultrasound-therapy resulted in better follicular preservation. Conclusion: The ultrasound therapy can improve preservation of ovarian follicle .This is probably due to acceleration of angiogenesis and increase in production of growth factors by low intensity pulse ultrasound.

  8. Photonuclear physics with low intensity photon beams

    International Nuclear Information System (INIS)

    Mecking, B.A.

    1985-01-01

    Experiments in photonuclear physics are discussed that require a low intensity photon beam and large acceptance detectors. This combination is especially suitable for the investigation of photoprocesses on nucleons and light nuclei. A specific experimental setup for the electron stretcher ring ELSA is presented. (orig.)

  9. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  10. Low-Intensity Repetitive Exercise Induced Rhabdomyolysis

    Directory of Open Access Journals (Sweden)

    Mina Tran

    2015-01-01

    Full Text Available Rhabdomyolysis is a rare condition caused by the proteins of damaged muscle cells entering the bloodstream and damaging the kidneys. Common symptoms of rhabdomyolysis are muscle pain and fatigue in conjunction with dark urine; kidney damage is a common symptom among these patients. We present a case of a 23-year-old woman who displayed myalgia in the upper extremities caused by low-intensity and high-repetition exercise. She was successfully diagnosed and treated for exertional rhabdomyolysis. This patient had no significant medical history that would induce this condition. We urge the emergency medical community to observe and monitor patients that complain of myalgia to ensure they are not suffering from rhabdomyolysis even in atypical cases.

  11. Ultrasound

    Science.gov (United States)

    ... completed. Young children may need additional preparation. When scheduling an ultrasound for yourself or your child, ask ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization ...

  12. Ultrasound

    Science.gov (United States)

    ... reflect off body structures. A computer receives the waves and uses them to create a picture. Unlike with an x-ray or CT scan, this test does not use ionizing radiation. The test is done in the ultrasound ...

  13. Keratomodelling with low-intensity ultraviolet radiation of excimer laser

    International Nuclear Information System (INIS)

    Vitrishchak, I.B.; Vorontsov, V.V.; Murzin, A.G.; Polikarpov, S.S.; Soms, L.N.

    1990-01-01

    A study was made on possibility of keratomodelling with low-intensive UV-radiation of excimer laser with subablation energy density in a pulse. Model specimens of polymers and cornea tissue were used. It is shown that the range of threshold energy density in a pulse expands with increase of UV-radiation wave length and contracts with increase of pulse repetition frequency. This range appeared to be different for polymers and cornea tissue. It was revealed that cornea tissue represented a complex high-molecular bipolymer with high water content

  14. Analysis of low-intensity scintillation spectra

    International Nuclear Information System (INIS)

    Muravsky, V.; Tolstov, S.A.

    2002-01-01

    The maximum likelihood algorithms for nuclides activities estimation from low intensity scintillation γ-ray spectra have been created. The algorithms treat full energy peaks and Compton parts of spectra, and they are more effective than least squares estimators. The factors that could lead to the bias of activity estimates are taken into account. Theoretical analysis of the problem of choosing the optimal set of initial spectra for the spectrum model to minimize errors of the activities estimation has been carried out for the general case of the N-components with Gaussian or Poisson statistics. The obtained criterion allows to exclude superfluous initial spectra of nuclides from the model. A special calibration procedure for scintillation γ-spectrometers has been developed. This procedure is required for application of the maximum likelihood activity estimators processing all the channels of the scintillation γ-spectrum, including the Compton part. It allows one to take into account the influence of the sample mass density variation. The algorithm for testing the spectrum model adequacy to the processed scintillation spectrum has been developed. The algorithms are realized in Borland Pascal 7 as a library of procedures and functions. The developed library is compatible with Delphi 1.0 and higher versions. It can be used as the algorithmic basis for analysis of highly sensitive scintillation γ- and β-spectrometric devices. (author)

  15. Stable cavitation induces increased cytoplasmic calcium in L929 fibroblasts exposed to 1-MHz pulsed ultrasound.

    Science.gov (United States)

    Tsukamoto, Akira; Higashiyama, Satoru; Yoshida, Kenji; Watanabe, Yoshiaki; Furukawa, Katsuko S; Ushida, Takashi

    2011-12-01

    An increase in cytoplasmic calcium (Ca(2+) increase) is a second messenger that is often observed under ultrasound irradiation. We hypothesize that cavitation is a physical mechanism that underlies the increase in Ca(2+) in these experiments. To control the presence of cavitation, the wave type was controlled in a sonication chamber. One wave type largely contained a traveling wave (wave type A) while the other wave type largely contained a standing wave (wave type B). Fast Fourier transform (FFT) analysis of a sound field produced by the wave types ascertained that stable cavitation was present only under wave type A ultrasound irradiation. Under the two controlled wave types, the increase in Ca(2+) in L929 fibroblasts was observed with fluorescence imaging. Under wave type A ultrasound irradiation, an increase in Ca(2+) was observed; however, no increase in Ca(2+) was observed under wave type B ultrasound irradiation. We conclude that stable cavitation is involved in the increase of Ca(2+) in cells subjected to pulsed ultrasound. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Point-of-care ultrasound education: the increasing role of simulation and multimedia resources.

    Science.gov (United States)

    Lewiss, Resa E; Hoffmann, Beatrice; Beaulieu, Yanick; Phelan, Mary Beth

    2014-01-01

    This article reviews the current technology, literature, teaching models, and methods associated with simulation-based point-of-care ultrasound training. Patient simulation appears particularly well suited for learning point-of-care ultrasound, which is a required core competency for emergency medicine and other specialties. Work hour limitations have reduced the opportunities for clinical practice, and simulation enables practicing a skill multiple times before it may be used on patients. Ultrasound simulators can be categorized into 2 groups: low and high fidelity. Low-fidelity simulators are usually static simulators, meaning that they have nonchanging anatomic examples for sonographic practice. Advantages are that the model may be reused over time, and some simulators can be homemade. High-fidelity simulators are usually high-tech and frequently consist of many computer-generated cases of virtual sonographic anatomy that can be scanned with a mock probe. This type of equipment is produced commercially and is more expensive. High-fidelity simulators provide students with an active and safe learning environment and make a reproducible standardized assessment of many different ultrasound cases possible. The advantages and disadvantages of using low- versus high-fidelity simulators are reviewed. An additional concept used in simulation-based ultrasound training is blended learning. Blended learning may include face-to-face or online learning often in combination with a learning management system. Increasingly, with simulation and Web-based learning technologies, tools are now available to medical educators for the standardization of both ultrasound skills training and competency assessment.

  17. Ultrasound stimulation of mandibular bone defect healing

    NARCIS (Netherlands)

    Schortinghuis, Jurjen

    2004-01-01

    The conclusions of the experimental work presented in this thesis are: 1. Low intensity pulsed ultrasound is not effective in stimulating bone growth into a rat mandibular defect, either with or without the use of osteoconductive membranes. 2. Low intensity pulsed ultrasound does not seem to have an

  18. Low-intensity beam diagnostics with particle detectors

    Energy Technology Data Exchange (ETDEWEB)

    Rovelli, A.; Ciavola, G.; Cuttone, G.; Finocchiaro, P.; Raia, G. [INFN-LNS, Via S. Sofia 44/A Catania, 95125 (Italy); De Martinis, C.; Giove, D. [INFN-LASA, Via F.lli Cervi 201 Segrate (Midway Islands), 20090 (Italy)

    1997-01-01

    The measure of low intensity beams at low-medium energy is one of the major challenge in beam diagnostics. This subject is of great interest for the design of accelerator-based medical and radioactive beam facilities. In this paper we discuss new developments in image-based devices to measure low-intensity beams. All the investigated devices must guarantee measurement of the total beam current and its transverse distribution. {copyright} {ital 1997 American Institute of Physics.}

  19. Low-intensity beam diagnostics with particle detectors

    International Nuclear Information System (INIS)

    Rovelli, A.; Ciavola, G.; Cuttone, G.; Finocchiaro, P.; Raia, G.; De Martinis, C.; Giove, D.

    1997-01-01

    The measure of low intensity beams at low-medium energy is one of the major challenge in beam diagnostics. This subject is of great interest for the design of accelerator-based medical and radioactive beam facilities. In this paper we discuss new developments in image-based devices to measure low-intensity beams. All the investigated devices must guarantee measurement of the total beam current and its transverse distribution. copyright 1997 American Institute of Physics

  20. Multiplane wave imaging increases signal-to-noise ratio in ultrafast ultrasound imaging

    International Nuclear Information System (INIS)

    Tiran, Elodie; Deffieux, Thomas; Correia, Mafalda; Maresca, David; Osmanski, Bruno-Felix; Pernot, Mathieu; Tanter, Mickael; Sieu, Lim-Anna; Bergel, Antoine; Cohen, Ivan

    2015-01-01

    Ultrafast imaging using plane or diverging waves has recently enabled new ultrasound imaging modes with improved sensitivity and very high frame rates. Some of these new imaging modalities include shear wave elastography, ultrafast Doppler, ultrafast contrast-enhanced imaging and functional ultrasound imaging. Even though ultrafast imaging already encounters clinical success, increasing even more its penetration depth and signal-to-noise ratio for dedicated applications would be valuable.Ultrafast imaging relies on the coherent compounding of backscattered echoes resulting from successive tilted plane waves emissions; this produces high-resolution ultrasound images with a trade-off between final frame rate, contrast and resolution. In this work, we introduce multiplane wave imaging, a new method that strongly improves ultrafast images signal-to-noise ratio by virtually increasing the emission signal amplitude without compromising the frame rate. This method relies on the successive transmissions of multiple plane waves with differently coded amplitudes and emission angles in a single transmit event. Data from each single plane wave of increased amplitude can then be obtained, by recombining the received data of successive events with the proper coefficients.The benefits of multiplane wave for B-mode, shear wave elastography and ultrafast Doppler imaging are experimentally demonstrated. Multiplane wave with 4 plane waves emissions yields a 5.8  ±  0.5 dB increase in signal-to-noise ratio and approximately 10 mm in penetration in a calibrated ultrasound phantom (0.7 d MHz −1 cm −1 ). In shear wave elastography, the same multiplane wave configuration yields a 2.07  ±  0.05 fold reduction of the particle velocity standard deviation and a two-fold reduction of the shear wave velocity maps standard deviation. In functional ultrasound imaging, the mapping of cerebral blood volume results in a 3 to 6 dB increase of the contrast-to-noise ratio in

  1. Lung surfactant microbubbles increase lipophilic drug payload for ultrasound-targeted delivery.

    Science.gov (United States)

    Sirsi, Shashank R; Fung, Chinpong; Garg, Sumit; Tianning, Mary Y; Mountford, Paul A; Borden, Mark A

    2013-01-01

    The cavitation response of circulating microbubbles to targeted ultrasound can be used for noninvasive, site-specific delivery of shell-loaded materials. One challenge for microbubble-mediated delivery of lipophilic compounds is the limitation of drug loading into the microbubble shell, which is commonly a single phospholipid monolayer. In this study, we investigated the use of natural lung surfactant extract (Survanta(®), Abbott Nutrition) as a microbubble shell material in order to improve drug payload and delivery. Pulmonary surfactant extracts such as Survanta contain hydrophobic surfactant proteins (SP-B and SP-C) that facilitate lipid folding and retention on lipid monolayers. Here, we show that Survanta-based microbubbles exhibit wrinkles in bright-field microscopy and increased lipid retention on the microbubble surface in the form of surface-associated aggregates observed with fluorescence microscopy. The payload of a model lipophilic drug (DiO), measured by flow cytometry, increased by over 2-fold compared to lipid-coated microbubbles lacking SP-B and SP-C. Lung surfactant microbubbles were highly echogenic to contrast enhanced ultrasound imaging at low acoustic intensities. At higher ultrasound intensity, excess lipid was observed to be acoustically cleaved for localized release. To demonstrate targeting, a biotinylated lipopolymer was incorporated into the shell, and the microbubbles were subjected to a sequence of radiation force and fragmentation pulses as they passed through an avidinated hollow fiber. Lung surfactant microbubbles showed a 3-fold increase in targeted deposition of the model fluorescent drug compared to lipid-only microbubbles. Our results demonstrate that lung surfactant microbubbles maintain the acoustic responsiveness of lipid-coated microbubbles with the added benefit of increased lipophilic drug payload.

  2. Strain ratio ultrasound elastography increases the accuracy of colour-Doppler ultrasound in the evaluation of Thy-3 nodules. A bi-centre university experience.

    Science.gov (United States)

    Cantisani, Vito; Maceroni, Piero; D'Andrea, Vito; Patrizi, Gregorio; Di Segni, Mattia; De Vito, Corrado; Grazhdani, Hektor; Isidori, Andrea M; Giannetta, Elisa; Redler, Adriano; Frattaroli, Fabrizio; Giacomelli, Laura; Di Rocco, Giorgio; Catalano, Carlo; D'Ambrosio, Ferdinando

    2016-05-01

    To assess whether ultrasound elastography (USE) with strain ratio increases diagnostic accuracy of Doppler ultrasound in further characterisation of cytologically Thy3 thyroid nodules. In two different university diagnostic centres, 315 patients with indeterminate cytology (Thy3) in thyroid nodules aspirates were prospectively evaluated with Doppler ultrasound and strain ratio USE before surgery. Ultrasonographic features were analysed separately and together as ultrasound score, to assess sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Receiver operating characteristic (ROC) curves to identify optimal cut-off value of the strain ratio were also provided. Diagnosis on a surgical specimen was considered the standard of reference. Higher strain ratio values were found in malignant nodules, with an optimum strain ratio cut-off of 2.09 at ROC analysis. USE with strain ratio showed 90.6% sensitivity, 93% specificity, 82.8% PPV, 96.4% NPV, while US score yielded a sensitivity of 52.9%, specificity of 84.3%, PPV 55.6% and NPV 82.9%. The diagnostic gain with strain ratio was statistically significant as proved by ROC areas, which was 0.9182 for strain ratio and 0.6864 for US score. USE with strain ratio should be considered a useful additional tool to colour-Doppler US, since it improves characterisation of thyroid nodules with indeterminate cytology. • Strain ratio measurements improve differentiation of thyroid nodules with indeterminate cytology • Elastography with strain ratio is more reliable than ultrasound features and ultrasound score • Strain ratio may help to better select patients with Thy 3 nodules candidate for surgery.

  3. On a low intensity 241 Am Compton spectrometer for measurement ...

    Indian Academy of Sciences (India)

    In this paper, a new design and construction of a low intensity (100 mCi) 241Am -ray Compton spectrometer is presented. The planar spectrometer is based on a small disc source with the shortest geometry. Measurement of the momentum density of polycrystalline Al is used to evaluate the performance of the new design.

  4. Can low-intensity extracorporeal shockwave therapy improve erectile dysfunction?

    DEFF Research Database (Denmark)

    Olsen, Anne B; Persiani, Marie; Boie, Sidsel

    2015-01-01

    OBJECTIVE: The aim of this study was to investigate whether low-intensity extracorporeal shockwave therapy (LI-ESWT) can be used as a treatment for men with erectile dysfunction of organic origin. MATERIALS AND METHODS: This prospective, randomized, blinded, placebo-controlled study included 112 ...... are needed. KEYWORDS: Erectile dysfunction; extracorporeal shockwave; penis...

  5. Low intensity surplus activated sludge pretreatment before anaerobic digestion

    Directory of Open Access Journals (Sweden)

    Suschka Jan

    2017-12-01

    Full Text Available Sewage sludge (municipal, or industrial treatment is still a problem in so far that it is not satisfactorily resolved in terms of cost and final disposal. Two common forms of sludge disposal are possible; the first being direct disposal on land (including agriculture and the second being incineration (ash production, although neither of these methods are universally applied. Simplifying the issue, direct sludge disposal on land is seldom applied for sanitary and environmental reasons, while incineration is not popular for financial (high costs reasons. Very often medium and large wastewater treatment plants apply anaerobic digestion for sludge hygiene principles, reducing the amount to be disposed and for biogas (energy production. With the progress in sewage biological treatment aiming at nutrient removal, primary sludge has been omitted in the working processes and only surplus activated sludge requires handling. Anaerobic digestion of waste activated sludge (WAS is more difficult due to the presence of microorganisms, the decomposition of which requires a relatively long time for hydrolysis. In order to upgrade the hydrolysis effects, several different pre-treatment processes have already been developed and introduced. The additional pre-treatment processes applied are aimed at residual sludge bulk mass minimization, shortening of the anaerobic digestion process or higher biogas production, and therefore require additional energy. The water-energy-waste Nexus (treads of of the benefits and operational difficulties, including energy costs are discussed in this paper. The intensity of pre-treatment processes to upgrade the microorganism’s hydrolysis has crucial implications. Here a low intensity pre-treatment process, alkalisation and hydrodynamic disintegration - hybrid process - were presented in order to achieve sufficient effects of WAS anaerobic digestion. A sludge digestion efficiency increase expressed as 45% biogas additional

  6. Ultrasound pregnancy

    Science.gov (United States)

    Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; ...

  7. EFFECT OF HIGH & LOW INTENSITIES OF AEROBIC EXERCISE ON PHYSICAL FITNESS INDEX

    Directory of Open Access Journals (Sweden)

    Madhusudhan

    2015-06-01

    Full Text Available BACKGROUND: Aerobic exercise reduces body fat and improves weight control, increases HDL&Vo2 max. Also improves PFI (physical fitness index which is defined as ability to carry out daily tasks with vigour and alertness without undue fatigue. Though aerobic exercise is found to improve physical fitness, the relative merits of different intensities of aerobi c exercise in improving physical fitness is still uncertain. AIM: The present study was conducted to know the Effect of High & low intensity aerobic training on physical fitness index. MATERIALS & METHODS : 80 sedentary men (18 - 40 years were randomized in to 2 equal groups (High Intensity & low intensity group . The High [80% HR max] & Low intensity [50 % HR max] groups underwent aerobic exercise training using Bicycle ergo meter (COSCO at 900kpm & 540kpm, for 15mins/day & 30mins/day respectively, 5days a week, for a period of 14weeks. Physical fitness index of each subject was recorded by Modified Harvard step test before & after intervention. RESULTS : After 14 weeks of aerobic training both the exercise groups had improvement in PFI, but high intensity gr oup had a significant (p<0.05 improvement in PFI (97.18 - 101.14 than low intensity group (98.12 - 100.6. CONCLUSION : High intensity aerobic exercise is effective in improving physical fitness.

  8. Nucleotide excision repair pathway assessment in DNA exposed to low-intensity red and infrared lasers

    International Nuclear Information System (INIS)

    Fonseca, A.S.; Campos, V.M.A.; Magalhaes, L.A.G.; Paoli, F.

    2015-01-01

    Low-intensity lasers are used for prevention and management of oral mucositis induced by anticancer therapy, but the effectiveness of treatment depends on the genetic characteristics of affected cells. This study evaluated the survival and induction of filamentation of Escherichia coli cells deficient in the nucleotide excision repair pathway, and the action of T 4 endonuclease V on plasmid DNA exposed to low-intensity red and near-infrared laser light. Cultures of wild-type (strain AB1157) E. coli and strain AB1886 (deficient in uvrA protein) were exposed to red (660 nm) and infrared (808 nm) lasers at various fluences, powers and emission modes to study bacterial survival and filamentation. Also, plasmid DNA was exposed to laser light to study DNA lesions produced in vitro by T 4 endonuclease V. Low-intensity lasers: i) had no effect on survival of wild-type E. coli but decreased the survival of uvrA protein-deficient cells, ii) induced bacterial filamentation, iii) did not alter the electrophoretic profile of plasmids in agarose gels, and iv) did not alter the electrophoretic profile of plasmids incubated with T 4 endonuclease V. These results increase our understanding of the effects of laser light on cells with various genetic characteristics, such as xeroderma pigmentosum cells deficient in nucleotide excision pathway activity in patients with mucositis treated by low-intensity lasers. (author)

  9. Nucleotide excision repair pathway assessment in DNA exposed to low-intensity red and infrared lasers

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, A.S.; Campos, V.M.A.; Magalhaes, L.A.G., E-mail: adnfonseca@ig.com.br [Instituto de Biologia Roberto Alcantara Gomes, Rio de Janeiro, RJ (Brazil). Departamento de Biofisica e Biometria. Lab. de Ciencias Radiologicas; Paoli, F. [Universidade Federal de Juiz de Fora (UFJF), Juiz de Fora, MG (Brazil). Instituto de Ciencias Biologicas. Departamento de Morfologia

    2015-10-15

    Low-intensity lasers are used for prevention and management of oral mucositis induced by anticancer therapy, but the effectiveness of treatment depends on the genetic characteristics of affected cells. This study evaluated the survival and induction of filamentation of Escherichia coli cells deficient in the nucleotide excision repair pathway, and the action of T{sub 4} endonuclease V on plasmid DNA exposed to low-intensity red and near-infrared laser light. Cultures of wild-type (strain AB1157) E. coli and strain AB1886 (deficient in uvrA protein) were exposed to red (660 nm) and infrared (808 nm) lasers at various fluences, powers and emission modes to study bacterial survival and filamentation. Also, plasmid DNA was exposed to laser light to study DNA lesions produced in vitro by T{sub 4} endonuclease V. Low-intensity lasers: i) had no effect on survival of wild-type E. coli but decreased the survival of uvrA protein-deficient cells, ii) induced bacterial filamentation, iii) did not alter the electrophoretic profile of plasmids in agarose gels, and iv) did not alter the electrophoretic profile of plasmids incubated with T{sub 4} endonuclease V. These results increase our understanding of the effects of laser light on cells with various genetic characteristics, such as xeroderma pigmentosum cells deficient in nucleotide excision pathway activity in patients with mucositis treated by low-intensity lasers. (author)

  10. Low-intensity training dissociates metabolic from aerobic fitness

    DEFF Research Database (Denmark)

    Helge, J W; Damsgaard, R; Overgaard, K

    2008-01-01

    This study investigated the effect of prolonged whole-body low-intensity exercise on blood lipids, skeletal muscle adaptations and aerobic fitness. Seven male subjects completed a 32-day crossing of the Greenland icecap on cross-country skies and before and after this arm or leg cranking was perf......This study investigated the effect of prolonged whole-body low-intensity exercise on blood lipids, skeletal muscle adaptations and aerobic fitness. Seven male subjects completed a 32-day crossing of the Greenland icecap on cross-country skies and before and after this arm or leg cranking...... sensitive lipase activity was similar in arm and leg muscle prior to the expedition and was not significantly affected by the crossing. In conclusion, an improved blood lipid profile and thus metabolic fitness was present after prolonged low-intensity training and this occurred in spite of a decreased...... aerobic fitness and an unchanged arm and leg muscle hormone-sensitive lipase activity....

  11. Magnetic resonance imaging-guided focused ultrasound to increase localized blood-spinal cord barrier permeability.

    Science.gov (United States)

    Payne, Allison H; Hawryluk, Gregory W; Anzai, Yoshimi; Odéen, Henrik; Ostlie, Megan A; Reichert, Ethan C; Stump, Amanda J; Minoshima, Satoshi; Cross, Donna J

    2017-12-01

    Spinal cord injury (SCI) affects thousands of people every year in the USA, and most patients are left with some permanent paralysis. Therapeutic options are limited and only modestly affect outcome. To address this issue, we used magnetic resonance imaging-guided focused ultrasound (MRgFUS) as a non-invasive approach to increase permeability in the blood-spinal cord barrier (BSCB). We hypothesize that localized, controlled sonoporation of the BSCB by MRgFUS will aid delivery of therapeutics to the injury. Here, we report our preliminary findings for the ability of MRgFUS to increase BSCB permeability in the thoracic spinal cord of a normal rat model. First, an excised portion of normal rat spinal column was used to characterize the acoustic field and to estimate the insertion losses that could be expected in an MRgFUS blood spinal cord barrier opening. Then, in normal rats, MRgFUS was applied in combination with intravenously administered microbubbles to the spinal cord region. Permeability of the BSCB was indicated as signal enhancement by contrast administered prior to T1-weighted magnetic resonance imaging and verified by Evans blue dye. Neurological testing using the Basso, Beattie, and Breshnahan scale and the ladder walk was normal in 8 of 10 rats tested. Two rats showed minor impairment indicating need for further refinement of parameters. No gross tissue damage was evident by histology. In this study, we have opened successfully the blood spinal cord barrier in the thoracic region of the normal rat spine using magnetic resonance-guided focused ultrasound combined with microbubbles.

  12. Post-General Anesthesia Ultrasound-Guided Venous Mapping Increases Autogenous Access Placement Rates.

    Science.gov (United States)

    Png, C Y Maximilian; Korayem, Adam; Finlay, David J

    2018-04-18

    between the groups in terms of outpatient vein mapping plans (P=0.10), however when comparing the PAUS plans to the outpatient vein mapping plans, there was again a significantly increased proportion of preferred access types in the PAUS group compared to the outpatient group (P<0.001). In the ordinal logit multivariate analysis, the only significant variable was the post-anesthesia ultrasound, which positively correlated with more favorable access configurations (coefficient=2.61, P<0.001). The bivariate logit regression for autogenous access maturation rates found no significant difference between the without-PAUS group and the PAUS group (P=0.13). Introducing a post-anesthesia ultrasound mapping to guide vein-finding significantly increases the quality and quantity of suitable veins found, subsequently leading to increased proportions preferred access placement (autogenous vs. prosthetic and forearm vs. upper extremity). Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Low-frequency ultrasound increases non-viral gene transfer to the mouse lung.

    Science.gov (United States)

    Xenariou, Stefania; Liang, Hai-Dong; Griesenbach, Uta; Zhu, Jie; Farley, Raymond; Somerton, Lucinda; Singh, Charanjit; Jeffery, Peter K; Scheule, Ronald K; Cheng, Seng H; Geddes, Duncan M; Blomley, Martin; Alton, Eric W F W

    2010-01-01

    The aim of the study was to assess if low-frequency ultrasound (US), in the range of 30-35 kHz, increases non-viral gene transfer to the mouse lung. US is greatly attenuated in the lung due to large energy losses at the air/tissue interfaces. The advantages of low-frequency US, compared with high-frequency US are: (i) increased cavitation (responsible for the formation of transient pores in the cell membrane) and (ii) reduced energy losses during lung penetration. Cationic lipid GL67/plasmid DNA (pDNA), polyethylenimine (PEI)/pDNA and naked pDNA were delivered via intranasal instillation and the animals were then exposed to US (sonoporation) at 0.07 or 0.1 MPa for 10 min. Under these conditions, US did not enhance GL67 or PEI-mediated transfection. It did, however, increase naked pDNA gene transfer by approximately 4 folds. Importantly, this was achieved in the absence of microbubbles, which are crucial for the commonly used high-frequency (1 MHz) sonoporation but may not be able to withstand nebulization in a clinically relevant setup. Lung hemorrhage was also assessed and shown to increase with US pressure in a dose-dependent manner. We have thus, established that low-frequency US can enhance lung gene transfer with naked pDNA and this enhancement is more effective than the previously reported 1 MHz US.

  14. Increased Incidence of Benign Pancreatic Pathology following Pancreaticoduodenectomy for Presumed Malignancy over 10 Years despite Increased Use of Endoscopic Ultrasound

    Directory of Open Access Journals (Sweden)

    Shadi S. Yarandi

    2014-01-01

    Full Text Available Despite using imaging studies, tissue sampling, and serologic tests about 5–10% of surgeries done for presumed pancreatic malignancies will have benign findings on final pathology. Endoscopic ultrasound (EUS is used with increasing frequency to study pancreatic masses. The aim of this study is to examine the effect of EUS on prevalence of benign diseases undergoing Whipple over the last decade. Patients who underwent Whipple procedure for presumed malignancy at Emory University Hospital from 1998 to 2011 were selected. Demographic data, history of smoking and drinking, history of diabetes and pancreatitis, imaging data, pathology reports, and tumor markers were extracted. 878 patients were found. 95 (10.82% patients had benign disease. Prevalence of benign finding had increased over the recent years despite using more EUS. Logistic regression models showed that abdominal pain (OR: 5.829, 95% CI 2.681–12.674, P ≤ 0.001 and alcohol abuse (OR: 3.221, CI 95%: 1.362–7.261, P: 0.002 were predictors of benign diseases. Jaundice (OR: 0.221, 95% CI: 0.084–0.58, P: 0.002, mass (OR: 0.145, 95% CI: 0.043–0.485, P: 0.008, and ductal dilation (OR: 0.297, 95% CI 0.134–0.657, P: 0.003 were associated with malignancy. Use of imaging studies, ERCP, and EUS has not decreased the percentage of benign findings after surgery for presumed pancreatic malignancy.

  15. Low-intensity interference effects and hidden-variable theories

    Energy Technology Data Exchange (ETDEWEB)

    Buonomano, V [Universidade Estadual de Campinas (Brazil). Inst. de Matematica

    1978-05-11

    The double-slit interference experiment and other similar experiments in the low-intensity limit (that is, one photon in the apparatus at a time) are examined in the spirit of Bell's work from the point of view of hidden-variable theories. It is found that there exists a class of hidden-variable theories which disagrees with quantum mechanics for a certain type of interference experiment. A manufactured conceptualization of this class, which is a particle view of interference, is described. An experiment, which appears to be feasible, is proposed to examine this disagreement.

  16. Sustained, Low?Intensity Exercise Achieved by a Dynamic Feeding System Decreases Body Fat in Ponies

    OpenAIRE

    de Laat, M.A.; Hampson, B.A.; Sillence, M.N.; Pollitt, C.C.

    2016-01-01

    Background Obesity in horses is increasing in prevalence and can be associated with insulin insensitivity and laminitis. Current treatment strategies for obesity include dietary restriction and exercise. However, whether exercise alone is effective for decreasing body fat is uncertain. Hypothesis Our hypothesis was that twice daily use of a dynamic feeding system for 3 months would induce sustained, low?intensity exercise thereby decreasing adiposity and improving insulin sensitivity (SI). An...

  17. Low intensity microwave radiation induced oxidative stress, inflammatory response and DNA damage in rat brain.

    Science.gov (United States)

    Megha, Kanu; Deshmukh, Pravin Suryakantrao; Banerjee, Basu Dev; Tripathi, Ashok Kumar; Ahmed, Rafat; Abegaonkar, Mahesh Pandurang

    2015-12-01

    Over the past decade people have been constantly exposed to microwave radiation mainly from wireless communication devices used in day to day life. Therefore, the concerns over potential adverse effects of microwave radiation on human health are increasing. Until now no study has been proposed to investigate the underlying causes of genotoxic effects induced by low intensity microwave exposure. Thus, the present study was undertaken to determine the influence of low intensity microwave radiation on oxidative stress, inflammatory response and DNA damage in rat brain. The study was carried out on 24 male Fischer 344 rats, randomly divided into four groups (n=6 in each group): group I consisted of sham exposed (control) rats, group II-IV consisted of rats exposed to microwave radiation at frequencies 900, 1800 and 2450 MHz, specific absorption rates (SARs) 0.59, 0.58 and 0.66 mW/kg, respectively in gigahertz transverse electromagnetic (GTEM) cell for 60 days (2h/day, 5 days/week). Rats were sacrificed and decapitated to isolate hippocampus at the end of the exposure duration. Low intensity microwave exposure resulted in a frequency dependent significant increase in oxidative stress markers viz. malondialdehyde (MDA), protein carbonyl (PCO) and catalase (CAT) in microwave exposed groups in comparison to sham exposed group (pmicrowave exposed groups (pmicrowave exposed animal (pmicrowave exposed groups as compared to their corresponding values in sham exposed group (pmicrowave radiation induces oxidative stress, inflammatory response and DNA damage in brain by exerting a frequency dependent effect. The study also indicates that increased oxidative stress and inflammatory response might be the factors involved in DNA damage following low intensity microwave exposure. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Does use of a PACS increase the number of images per study? A case study in ultrasound.

    Science.gov (United States)

    Horii, Steven; Nisenbaum, Harvey; Farn, James; Coleman, Beverly; Rowling, Susan; Langer, Jill; Jacobs, Jill; Arger, Peter; Pinheiro, Lisa; Klein, Wendy; Reber, Michele; Iyoob, Christopher

    2002-03-01

    The purpose of this study was to determine if the use of a picture archiving and communications system (PACS) in ultrasonography increased the number of images acquired per examination. The hypothesis that such an increase does occur was based on anecdotal information; this study sought to test the hypothesis. A random sample of all ultrasound examination types was drawn from the period 1998 through 1999. The ultrasound PACS in use (ACCESS; Kodak Health Information Systems, Dallas, TX) records the number of grayscale and color images saved as part of each study. Each examination in the sample was checked in the ultrasound PACS database,.and the number of grayscale and color images was recorded. The comparison film-based sample was drawn from the period 1994 through 1995. The number of examinations of each type selected was based on the overall statistics of the section; that is, the sample was designed to represent the approximate frequency with which the various examination types are done. For film-based image counts, the jackets were retrieved, and the number of grayscale and color images were counted. The number of images obtained per examination (for most examinations) in ultrasound increased with PACS use. This was more evident with some examination types (eg, pelvis). This result, however, has to be examined for possible systematic biases because ultrasound practice has changed over the time since the authors stopped using film routinely. The use of PACS in ultrasonography was not associated with an increase in the number of images per examination based solely on the use of PACS, with the exception of neonatal head studies. Increases in the number of images per study was otherwise associated with examinations for which changes in protocols resulted in the increased image counts.

  19. Specific features of peroxide stress in children permanently exposed to low-intensity radiation

    International Nuclear Information System (INIS)

    Durnov, L.A.; Bajkova, V.N.; Mayakova, S.A.; Polyakov, V.G.; Kolosov, E.A.; Dumbrajs, K.O.; Gracheva, I.V.; Zakharova, N.V.; Leonidova, Yu.A.; Romanova, L.F.

    2000-01-01

    To study the peculiarities of peroxide stress in children residing at the territories with chronic low-intensity radiation effects, the investigation was performed of tyrosine level, indices of the intensity of free radical lipid peroxidation and antioxidant system status in children and teenagers living in Sverdlovsk and Kolpnyansk districts of the Orel region contaminated due to the Chernobyl accident. Regions mentioned are characterized by low-intensity contamination with radionuclides (mainly 90 Sr, 131 I, 137 Cs), 25% an increase in tyrosine content, 1.8 times in malonic dial, 25-40 % in catalase and superoxide dismutase activity was revealed in blood plasma. Contents of A and E vitamins, glutathione and glutathione-depending enzymes are decreased. It is recommended to observe children health in regions contaminated as a result of the Chernobyl accident and correct failed redox processes using antioxidative vitamins [ru

  20. Transrectal ultrasound-guided biopsy of the prostate: aspirin increases the incidence of minor bleeding complications

    International Nuclear Information System (INIS)

    Halliwell, O.T.; Yadegafar, G.; Lane, C.; Dewbury, K.C.

    2008-01-01

    Aim: To assess whether patients taking aspirin were more likely to experience bleeding complications after transrectal ultrasound (TRUS)-guided prostate biopsy. Materials and methods: Three hundred and eighty-seven patients taking aspirin who underwent prostate biopsy over a 3.5 year period and 731 patients not taking aspirin over a 2 year period returned a questionnaire assessing the incidence and severity of bleeding complications. Results: Patients taking aspirin had a significantly higher cumulative incidence of haematuria and rectal bleeding, but not of haemospermia. They also had a longer mean duration of bleeding, but no increase in bleeding severity. Severe bleeding was very uncommon in both groups and no patients required intervention for bleeding complications. Conclusion: Aspirin exacerbates minor bleeding complications in patients undergoing TRUS guided biopsy of the prostate, but in this large group of aspirin-taking patients no dangerous bleeding complications were encountered. It may be that the risks associated with aspirin cessation outweigh the risks of haemorrhagic complications

  1. Transrectal ultrasound-guided biopsy of the prostate: aspirin increases the incidence of minor bleeding complications

    Energy Technology Data Exchange (ETDEWEB)

    Halliwell, O.T. [Department of Radiology, Southampton General Hospital, Southampton (United Kingdom)], E-mail: hallo99@doctors.org.uk; Yadegafar, G. [Public Health Sciences and Medical Statistics Division, School of Medicine, Southampton General Hospital, Southampton University, Southampton (United Kingdom); Lane, C.; Dewbury, K.C. [Department of Radiology, Southampton General Hospital, Southampton (United Kingdom)

    2008-05-15

    Aim: To assess whether patients taking aspirin were more likely to experience bleeding complications after transrectal ultrasound (TRUS)-guided prostate biopsy. Materials and methods: Three hundred and eighty-seven patients taking aspirin who underwent prostate biopsy over a 3.5 year period and 731 patients not taking aspirin over a 2 year period returned a questionnaire assessing the incidence and severity of bleeding complications. Results: Patients taking aspirin had a significantly higher cumulative incidence of haematuria and rectal bleeding, but not of haemospermia. They also had a longer mean duration of bleeding, but no increase in bleeding severity. Severe bleeding was very uncommon in both groups and no patients required intervention for bleeding complications. Conclusion: Aspirin exacerbates minor bleeding complications in patients undergoing TRUS guided biopsy of the prostate, but in this large group of aspirin-taking patients no dangerous bleeding complications were encountered. It may be that the risks associated with aspirin cessation outweigh the risks of haemorrhagic complications.

  2. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  3. A standardized approach to study human variability in isometric thermogenesis during low-intensity physical activity

    Directory of Open Access Journals (Sweden)

    Delphine eSarafian

    2013-07-01

    Full Text Available Limitations of current methods: The assessment of human variability in various compartments of daily energy expenditure (EE under standardized conditions is well defined at rest (as basal metabolic rate and thermic effect of feeding, and currently under validation for assessing the energy cost of low-intensity dynamic work. However, because physical activities of daily life consist of a combination of both dynamic and isometric work, there is also a need to develop standardized tests for assessing human variability in the energy cost of low-intensity isometric work.Experimental objectives: Development of an approach to study human variability in isometric thermogenesis by incorporating a protocol of intermittent leg press exercise of varying low-intensity isometric loads with measurements of EE by indirect calorimetry. Results: EE was measured in the seated position with the subject at rest or while intermittently pressing both legs against a press-platform at 5 low-intensity isometric loads (+5, +10, + 15, +20 and +25 kg force, each consisting of a succession of 8 cycles of press (30 s and rest (30 s. EE, integrated over each 8-min period of the intermittent leg press exercise, was found to increase linearly across the 5 isometric loads with a correlation coefficient (r > 0.9 for each individual. The slope of this EE-Load relationship, which provides the energy cost of this standardized isometric exercise expressed per kg force applied intermittently (30 s in every min, was found to show good repeatability when assessed in subjects who repeated the same experimental protocol on 3 separate days: its low intra-individual coefficient of variation (CV of ~ 10% contrasted with its much higher inter-individual CV of 35%; the latter being mass-independent but partly explained by height. Conclusion: This standardized approach to study isometric thermogenesis opens up a new avenue for research in EE phenotyping and metabolic predisposition to obesity

  4. The effects of a low-intensity red laser on bacterial growth, filamentation and plasmid DNA

    International Nuclear Information System (INIS)

    Roos, C; Santos, J N; Guimarães, O R; Geller, M; Fonseca, A S; Paoli, F

    2013-01-01

    Exposure of nonphotosynthesizing microorganisms to light could increase cell division in cultures, a phenomenon denominated as biostimulation. However, data concerning the importance of the genetic characteristics of cells on this effect are as yet scarce. The aim of this work was to evaluate the effects of a low-intensity red laser on the growth, filamentation and plasmids in Escherichia coli cells proficient and deficient in DNA repair. E. coli cultures were exposed to a laser (658 nm, 10 mW, 1 and 8 J cm −2 ) to study bacterial growth and filamentation. Also, bacterial cultures hosting pBSK plasmids were exposed to the laser to study DNA topological forms from the electrophoretic profile in agarose gels. Data indicate the low-intensity red laser: (i) had no effect on the growth of E. coli wild type and exonuclease III deficient cells; (ii) induced bacterial filamentation, (iii) led to no alteration in the electrophoretic profile of plasmids from exonuclease III deficient cells, but plasmids from wild type cells were altered. A low-intensity red laser at the low fluences used in phototherapy has no effect on growth, but induces filamentation and alters the topological forms of plasmid DNA in E. coli cultures depending on the DNA repair mechanisms. (paper)

  5. [Suppression of visceral pain by action of the low intensity polarized light on acupuncture antinociceptive points].

    Science.gov (United States)

    Lymans'kyĭ, Iu P; Tamarova, Z A; Huliar, S O

    2003-01-01

    In experiments on mice, statistically authentic weakening of visceral pain has been shown after an action of low intensity polarized light from a device Bioptron on antinociceptive acupuncture points (AP). Pain was caused by an intraperitoneal injection of 2% acetic acid (0.1 ml/10 g). The intensity of pain was judged on duration and frequency of painful behavioral reactions (writhing, licking of abdomen), as well as on duration of sleep, eating and motor activity. In animals which immediately after injections of acetic acid were exposed to polarized light of low intensity for 10 min, applied on any of antinociceptive APs (E-36, E-43, VC-8, RP-6), the duration of painful behavioral reaction was determined to be reduced, while that of non-painful one increased. The comparison of the total duration of the writhing at control and experimental mice showed that an activation of AP E-43 induced the greatest analgesic effect (76.5%), from AP VC-8 it was 76.3%, from RP-6--46.8%, and from E-36--41.4%. We have concluded that the effect of polarized light of low intensity on APs was a convenient non-pharmacological method of treating visceral pain.

  6. Very low intensity storage-ring profile monitor

    International Nuclear Information System (INIS)

    Hardek, T.; Kells, W.; Lai, H.

    1981-01-01

    The Fermilab Colliding Beams Group has now accomplished several cooling experiments (electron and stochastic methods) on proton beams in the ''electron cooling'' synchrotron ring built for this purpose. A key to analyzing the performance of any test cooling system is a complete set of beam diagnostics to measure the beam emittances in all three planes. For longitudinal emittance the authors use Schottky scans (although very low intensities make this difficult, necessitating a departure from the conventional method by bunching the beams). A description is given of the MCP telescope and readout which evolved independently as a complete monitor system using residual gas in lieu of Mg vapor. To date all transverse measurements of coasting beam profiles have been obtained in this mode. 2 refs

  7. Low-Intensity Extracorporeal Shockwave Therapy in Sexual Medicine

    DEFF Research Database (Denmark)

    Fode, Mikkel; Lowenstein, Lior; Reisman, Yacov

    2017-01-01

    INTRODUCTION: Low-intensity extracorporeal shockwave therapy (LI-ESWT) has emerged as a treatment option for male sexual dysfunction. However, results have been contradictory. AIM: To investigate the knowledge, practice patterns, and attitudes regarding LI-ESWT among experts in sexual medicine....... METHODS: A study-specific questionnaire was handed out at the 18th Congress for the European Society for Sexual Medicine. Participants were queried on their knowledge about LI-ESWT and about their use of the equipment. MAIN OUTCOME MEASURES: Descriptive data on the knowledge of LI-ESWT and perception...... of treatment effects. RESULTS: One hundred ninety-two questionnaires were available for analysis. Most respondents were physicians (79.7%) and most of these specialized in urology (58.9%). Overall, 144 of 192 (75%) reported that they were familiar with LI-ESWT in sexual medicine. Twenty-seven (14.1%) had...

  8. Optimizing a novel method for low intensity ultrasound in chondrogenesis induction

    Directory of Open Access Journals (Sweden)

    Hajar Shafaei

    2013-01-01

    Conclusion: Using LIUS resulted in early chondrogenesis in comparison with terminally differentiated chondrocytes by TGFβ. Therefore, LIUS might provide an applicable, safe, efficient, and cheap tool for chondrogenic differentiation of ASCs in cartilage tissue engineering.

  9. A low-cost ultrasound program leads to increased antenatal clinic visits and attended deliveries at a health care clinic in rural Uganda.

    Directory of Open Access Journals (Sweden)

    Andrew B Ross

    Full Text Available BACKGROUND: In June of 2010, an antenatal ultrasound program to perform basic screening for high-risk pregnancies was introduced at a community health care center in rural Uganda. Whether the addition of ultrasound scanning to antenatal visits at the health center would encourage or discourage potential patients was unknown. Our study sought to evaluate trends in the numbers of antenatal visits and deliveries at the clinic, pre- and post-introduction of antenatal ultrasound to determine what effect the presence of ultrasound at the clinic had on these metrics. METHODS AND FINDINGS: Records at Nawanyago clinic were reviewed to obtain the number of antenatal visits and deliveries for the 42 months preceding the introduction of ultrasound and the 23 months following. The monthly mean deliveries and antenatal visits by category (first visit through fourth return visit were compared pre- and post- ultrasound using a Kruskal-Wallis one-way ANOVA. Following the introduction of ultrasound, significant increases were seen in the number of mean monthly deliveries and antenatal visits. The mean number of monthly deliveries at the clinic increased by 17.0 (13.3-20.6, 95% CI from a pre-ultrasound average of 28.4 to a post-ultrasound monthly average of 45.4. The number of deliveries at a comparison clinic remained flat over this same time period. The monthly mean number of antenatal visits increased by 97.4 (83.3-111.5, 95% CI from a baseline monthly average of 133.5 to a post-ultrasound monthly mean of 231.0, with increases seen in all categories of antenatal visits. CONCLUSIONS: The availability of a low-cost antenatal ultrasound program may assist progress towards Millennium Development Goal 5 by encouraging women in a rural environment to come to a health care facility for skilled antenatal care and delivery assistance instead of utilizing more traditional methods.

  10. Low Intensity Laser Therapy Applied in the Healing of Wounds

    Science.gov (United States)

    Kahn, Fred; Matthews, Jeffrey

    2009-06-01

    Objective: The aim of this study was to determine the outcomes of Low Intensity Laser Therapy (LILT) on wound healing for patients presenting with pain, compromised neurological and physical function and tissue damage associated with vascular/diabetic ulcerations of the lower extremity. Methods: A retrospective case review of six patients treated with LILT (GaAlAs SLD, 660 nm, 750 mW, 3.6 J/cm2; GaAlAs SLD, 840 nm, 1,500 mW, 6.48 J/cm2; GaAlAs laser, 830 nm, 75 mW, 270 J/cm2) was conducted of clinical features including pain, measured by visual analogue scale (VAS), motor function, measured by range of motion (ROM) and visual outcome, measured by wound dimensions for six patients (n = 6; 5 males, 1 female; age = 67.83 years). Results: Significant progress with regard to alleviation of pain (ΔVAS = -5), improvements in motor function (ΔROM = +40%), epithelialization (wound closure rate = 3%/week) and complete wound closure was achieved. No recurrence of pathology at least one month post cessation of therapy was evident (x¯% reduction in wound area = 100%). Conclusions: LILT achieved consistent, effective and clear endpoints, was cost effective, created no adverse effects and ultimately led to the salvage of extremities.

  11. Evaluation of the ocular protection for low intensity therapeutic lasers

    International Nuclear Information System (INIS)

    Cordon, Rosely

    2003-01-01

    The low intensity laser therapy (LILT) has been extensively used in medicine and dentistry presenting positive effects. However, the laser radiation can also cause adverse effects. Due to the ocular focalization property, in the wavelength from 400 to 1400 nm, the retina is more susceptible to damage by radiation than any other part of the human body. Then, the ocular protection is frequently emphasized. This protection must attenuate the radiation to a safe level. The International Electrotechnical Commission (IEC) standard IEC 60825-1 suggests safety requirements for medical laser equipment, including the ocular protection, based on maximum permissible exposure levels. The Brazilian legislation adopts a corresponding IEC standard, the NBR IEC 601.2.22, for safety requirements. The aim of this study was to analyze the adequacy of the ocular protectors furnished by four laser equipment manufacturers, commercially available in Brazil, commonly used for LILT. For this purpose, the laser equipment and the respective ocular protectors were characterized. The adequacy was verified according to the IEC standards. It was found, among other results, ocular protectors attenuating to safe levels the radiation emitted by the respective laser equipment, however, presenting inadequate visual transmission. Inefficient protection and protection indicated in cases where they were not necessary were also observed. (author)

  12. Evaluation of low-intensity physical activity by triaxial accelerometry.

    Science.gov (United States)

    Midorikawa, Taishi; Tanaka, Shigeho; Kaneko, Kayoko; Koizumi, Kayo; Ishikawa-Takata, Kazuko; Futami, Jun; Tabata, Izumi

    2007-12-01

    To develop regression-based equations that estimate physical activity ratios [energy expenditure (EE) per minute/sleeping metabolic rate] for low-to-moderate intensity activities using total acceleration obtained by triaxial accelerometry. Twenty-one Japanese adults were fitted with a triaxial accelerometer while also in a whole-body human calorimeter for 22.5 hours. The protocol time was composed of sleep (8 hours), four structured activity periods totaling 4 hours (sitting, standing, housework, and walking on a treadmill at speeds of 71 and 95 m/min, 2 x 30 minutes for each activity), and residual time (10.5 hours). Acceleration data (milligausse) from the different periods and their relationship to physical activity ratio obtained from the human calorimeter allowed for the development of EE equations for each activity. The EE equations were validated on the residual times, and the percentage difference for the prediction errors was calculated as (predicted value - measured value)/measured value x 100. Using data from triaxial accelerations and the ratio of horizontal to vertical accelerations, there was relatively high accuracy in identifying the four different periods of activity. The predicted EE (882 +/- 150 kcal/10.5 hours) was strongly correlated with the actual EE measured by human calorimetry (846 +/- 146 kcal/10.5 hours, r = 0.94 p types of activities and estimate EE for low-intensity physical activities associated with modern lifestyles.

  13. Lung Surfactant Microbubbles Increase Lipophilic Drug Payload for Ultrasound-Targeted Delivery

    OpenAIRE

    Sirsi, Shashank R.; Fung, Chinpong; Garg, Sumit; Tianning, Mary Y.; Mountford, Paul A.; Borden, Mark A.

    2013-01-01

    The cavitation response of circulating microbubbles to targeted ultrasound can be used for noninvasive, site-specific delivery of shell-loaded materials. One challenge for microbubble-mediated delivery of lipophilic compounds is the limitation of drug loading into the microbubble shell, which is commonly a single phospholipid monolayer. In this study, we investigated the use of natural lung surfactant extract (Survanta?, Abbott Nutrition) as a microbubble shell material in order to improve dr...

  14. Assessing Low-Intensity Relationships in Complex Networks

    Science.gov (United States)

    Spitz, Andreas; Gimmler, Anna; Stoeck, Thorsten; Zweig, Katharina Anna; Horvát, Emőke-Ágnes

    2016-01-01

    Many large network data sets are noisy and contain links representing low-intensity relationships that are difficult to differentiate from random interactions. This is especially relevant for high-throughput data from systems biology, large-scale ecological data, but also for Web 2.0 data on human interactions. In these networks with missing and spurious links, it is possible to refine the data based on the principle of structural similarity, which assesses the shared neighborhood of two nodes. By using similarity measures to globally rank all possible links and choosing the top-ranked pairs, true links can be validated, missing links inferred, and spurious observations removed. While many similarity measures have been proposed to this end, there is no general consensus on which one to use. In this article, we first contribute a set of benchmarks for complex networks from three different settings (e-commerce, systems biology, and social networks) and thus enable a quantitative performance analysis of classic node similarity measures. Based on this, we then propose a new methodology for link assessment called z* that assesses the statistical significance of the number of their common neighbors by comparison with the expected value in a suitably chosen random graph model and which is a consistently top-performing algorithm for all benchmarks. In addition to a global ranking of links, we also use this method to identify the most similar neighbors of each single node in a local ranking, thereby showing the versatility of the method in two distinct scenarios and augmenting its applicability. Finally, we perform an exploratory analysis on an oceanographic plankton data set and find that the distribution of microbes follows similar biogeographic rules as those of macroorganisms, a result that rejects the global dispersal hypothesis for microbes. PMID:27096435

  15. SALIVARY CORTISOL RESPONSES AND PERCEIVED EXERTION DURING HIGH INTENSITY AND LOW INTENSITY BOUTS OF RESISTANCE EXERCISE

    Directory of Open Access Journals (Sweden)

    Alison D. Egan

    2004-03-01

    Full Text Available The purpose of this study was to measure the salivary cortisol response to different intensities of resistance exercise. In addition, we wanted to determine the reliability of the session rating of perceived exertion (RPE scale to monitor resistance exercise intensity. Subjects (8 men, 9 women completed 2 trials of acute resistance training bouts in a counterbalanced design. The high intensity resistance exercise protocol consisted of six, ten-repetition sets using 75% of one repetition maximum (RM on a Smith machine squat and bench press exercise (12 sets total. The low intensity resistance exercise protocol consisted of three, ten-repetition sets at 30% of 1RM of the same exercises as the high intensity protocol. Both exercise bouts were performed with 2 minutes of rest between each exercise and sessions were repeated to test reliability of the measures. The order of the exercise bouts was randomized with least 72 hours between each session. Saliva samples were obtained immediately before, immediately after and 30 mins following each resistance exercise bout. RPE measures were obtained using Borg's CR-10 scale following each set. Also, the session RPE for the entire exercise session was obtained 30 minutes following completion of the session. There was a significant 97% increase in the level of salivary cortisol immediately following the high intensity exercise session (P<0.05. There was also a significant difference in salivary cortisol of 145% between the low intensity and high intensity exercise session immediately post-exercise (P<0.05. The low intensity exercise did not result in any significant changes in cortisol levels. There was also a significant difference between the session RPE values for the different intensity levels (high intensity 7.1 vs. low intensity 1.9 (P<0.05. The intraclass correlation coefficient for the session RPE measure was 0.95. It was concluded that the session RPE method is a valid and reliable method of

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and ...

  19. [Reparative Osteogenesis and Angiogenesis in Low Intensity Electromagnetic Radiation of Ultra-High Frequency].

    Science.gov (United States)

    Iryanov, Y M; Kiryanov, N A

    2015-01-01

    Non-drug correction of reparative bone tissue regeneration in different pathological states - one of the most actual problems of modern medicine. Our aim was to conduct morphological analysis of the influence of electromagnetic radiation of ultra-high frequency and low intensity on reparative osteogenesis and angiogenesis in fracture treatment under transosseous osteosynthesis. A controlled nonrandomized study was carried out. In the experiment conducted on rats we modeled tibial fracture with reposition and fixation of the bone fragments both in control and experimental groups. In the animals of the experimental group the fracture zone was exposed to low intensity electromagnetic radiation of ultra-high frequency. Exposure simulation was performed in the control group. The operated bones were examined using radiography, light and electronic microscopy, X-ray electronic probe microanalysis. It has been established that electromagnetic radiation of ultra-high frequency sessions in fracture treatment stimulate secretory activity and degranulation of mast cells, produce microcirculatory bed vascular permeability increase, endotheliocyte migration phenotype expression, provide endovascular endothelial outgrowth formation, activate reparative osteogenesis and angiogenesis while fracture reparation becomes the one of the primary type. The full periosteal, intermediary and intraosteal bone union was defined in 28 days. Among the therapeutic benefits of electromagnetic radiation of ultra-high frequency in fracture treatment we can detect mast cell secretorv activity stimulation and endovascular anziozenesis activation.

  20. Effects of fat adaptation on glucose kinetics and substrate oxidation during low-intensity exercise.

    Science.gov (United States)

    Pagan, J D; Geor, R J; Harris, P A; Hoekstra, K; Gardner, S; Hudson, C; Prince, A

    2002-09-01

    This study was designed to determine the effects of fat adaptation on carbohydrate and fat oxidation in conditioned horses during low-intensity exercise. Five mature Arabians were studied. The study was conducted as a crossover design with 2 dietary periods, each of 10 week's duration: a) a control (CON) diet, and b) a fat-supplemented (FAT) diet. The total amount of digestible energy (DE) supplied by the fat in the CON and FAT diets was 7% and 29%, respectively. During each period, the horses completed exercise tests at the beginning of the period (Week 0) and after 5 and 10 weeks on the diet. Tests consisted of 90 min of exercise at a speed calculated to elicit 35% VO2max on a treadmill inclined to 3 degrees. Oxygen consumption (VO2), carbon dioxide production (VCO2), and respiratory exchange ratio (RER) were measured at 15-min intervals. For determination of glucose kinetics, a stable isotope ([6-6-d2] glucose) technique was used. Compared to the CON diet, FAT diet consumption for 5-10 weeks was associated with an altered metabolic response to low-intensity exercise, as evidenced by a more than 30% reduction in the production and utilisation of glucose; a decrease in RER; a decrease in the estimated rate of whole-body carbohydrate utilisation; and an increase in the whole-body rate of lipid oxidation during exercise.

  1. Application of the Non-Intervention Principle to Low-Intensity Cyber Operations

    OpenAIRE

    Adamson, Liisi

    2015-01-01

    Present work focuses on the non-intervention principle and low-intensity cyber operations. More specifically, its main question is, whether the principle of non-intervention applies to low-intensity cyber operations and if it does, is the legal framework of non-intervention principle an effective way to regulate peacetime low-intensity cyber operations. Information Age and the rapid development of ICTs have provided hostile actors the opportunity to exploit the advantages cyberspace offe...

  2. Microbubble-Mediated Ultrasound Enhances the Lethal Effect of Gentamicin on Planktonic Escherichia coli

    Directory of Open Access Journals (Sweden)

    Han-Xiao Zhu

    2014-01-01

    Full Text Available Previous research has found that low-intensity ultrasound enhanced the lethal effect of gentamicin on planktonic E. coli. We aimed to further investigate whether microbubble-mediated low-intensity ultrasound could further enhance the antimicrobial efficacy of gentamicin. The planktonic E. coli (ATCC 25922 was distributed to four different interventions: control (GCON, microbubble only (GMB, ultrasound only (GUS, and microbubble-mediated ultrasound (GMUS. Ultrasound was applied with 100 mW/cm2 (average intensity and 46.5 KHz, which presented no bactericidal activity. After 12 h, plate counting was used to estimate the number of bacteria, and bacterial micromorphology was observed with transmission electron microscope. The results showed that the viable counts of E. coli in GMUS were decreased by 1.01 to 1.42 log10 CFU/mL compared with GUS (P<0.01. The minimal inhibitory concentration (MIC of gentamicin against E. coli was 1 μg/mL in the GMUS and GUS groups, lower than that in the GCON and GMB groups (2 μg/mL. Transmission electron microscopy (TEM images exhibited more destruction and higher thickness of bacterial cell membranes in the GMUS than those in other groups. The reason might be the increased permeability of cell membranes for gentamicin caused by acoustic cavitation.

  3. Impact of a low intensity controlled-fire in some chemical soil properties.

    Science.gov (United States)

    Martínez-Murillo, Juan F.; Hueso-González, Paloma; Aranda-Gómez, Francisco; Damián Ruiz-Sinoga, José

    2014-05-01

    Some changes in chemical soil properties can be observed after fires of low intensities. pH and electric conductivity tend to increase, while C/N ratio decrease. In the case of organic matter, the content can increase due to the massive incorporation of necromass including, especially, plants and roots. The aim of this study is to assess the impact of low intensity and controlled fire in some soil properties in field conditions. El Pinarillo experimental area is located in South of Spain. Two set of closed plots were installed (24 m2: 12 m length x 2 m width). One of them was remained as control with the original vegetation cover (Mediterranean matorral: Rosmarinus officinalis, Cistus clusii, Lavandula stoechas, Chamaeropos humilis, Thymus baetica), and the other one was burnt in a controlled-fire in 2011. Weather conditions and water content of vegetation influenced in the intensity of fire (low). After the controlled-fire, soil surface sample (0-5 cm) were taken in both set of plots (B, burnt soil samples; C, control soil samples). Some soil chemical properties were analysed: organic matter content (OM), C/N ratio, pH and electrical conductivity (EC). Some changes were observed in B corroborating a controlled-fire of low intensity. pH remained equal after fire (B: pH=7.7±0.11; C: pH=7.7±0.04). An increment was obtained in the case of EC (B: EC=0.45 mScm-1±0.08 mScm-1; C: EC=0.35 mScm-1±0.07 mScm-1) and OM (B: OM=8.7%±3.8%; C: pH=7.3%±1.5%). Finally, C/N ratio decreased after fire respect to the control and initial conditions (B: C/N=39.0±14.6; C: C/N =46.5±10.2).

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to ... Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces pictures ...

  5. [Low-intensity, evidence-based cognitive-behavioural therapy of a patient with Crohn's disease].

    Science.gov (United States)

    Antal-Uram, Dóra; Harsányi, László; Perczel-Forintos, Dóra

    2018-03-01

    Inflammatory bowel disease (Crohn's disease and colitis ulcerosa) is a chronic, long-term condition that causes chronic inflammation in the digestive tract, and shows an increasing incidence and prevalence worldwide. Changes in disease activity over time affect psychological distress which increases the risk of exacerbations. Beside somatic symptoms (such as abdominal pain, diarrhoea and weight loss), psychiatric comorbidity (in particular major depression, anxiety, social phobia) is common in patients with Crohn's disease. This case study illustrates the management and stabilization of a 21-year-old adult male patient with active Crohn's disease and with severe psychiatric comorbidity. The patient was diagnosed with avoidant personality disorder and dysruptive mood dysregulation disorder based on the results of psychodiagnostics (SCID-II structured clinical interview, MMPI personality inventory and disease-specific clinical questionnaires such as Beck Depression Inventory, Beck Hopelessness Scale, Social Cognition Questionnaire, Anger Expression Scale, Cognitive Emotion Regulation Questionnaire, Rosenberg Self-Esteem Scale). The main aim of psychotherapy is to increase the adherence to pharmacotherapy, to promote psychosocial functioning, to improve well-being and to enhance adaptive coping strategies. Low-intensity cognitive-behavioural psychotherapy was used which included psychoeducation, motivational interview, behavioural activation, patient diary, cognitive restructuring, problem-solving training, and family consulting. Twenty-five sessions were held weekly in outpatient form and 3 sessions of crisis intervention after the surgery at the hospital. The efficacy of the treatment was measured by self-reported questionnaires at baseline and at two follow-up sessions which corroborated a very significant decrease in the severity of depression, hopelessness, while emotional regulation and self-esteem became more adaptive. The remission of the above

  6. What does low-intensity rTMS do to the cerebellum?

    Science.gov (United States)

    Morellini, N; Grehl, S; Tang, A; Rodger, J; Mariani, J; Lohof, A M; Sherrard, R M

    2015-02-01

    Non-invasive stimulation of the human cerebellum, such as by transcranial magnetic stimulation (TMS), is increasingly used to investigate cerebellar function and identify potential treatment for cerebellar dysfunction. However, the effects of TMS on cerebellar neurons remain poorly defined. We applied low-intensity repetitive TMS (LI-rTMS) to the mouse cerebellum in vivo and in vitro and examined the cellular and molecular sequelae. In normal C57/Bl6 mice, 4 weeks of LI-rTMS using a complex biomimetic high-frequency stimulation (BHFS) alters Purkinje cell (PC) dendritic and spine morphology; the effects persist 4 weeks after the end of stimulation. We then evaluated whether LI-rTMS could induce climbing fibre (CF) reinnervation to denervated PCs. After unilateral pedunculotomy in adult mice and 2 weeks sham or BHFS stimulation, VGLUT2 immunohistochemistry was used to quantify CF reinnervation. In contrast to sham, LI-rTMS induced CF reinnervation to the denervated hemicerebellum. To examine potential mechanisms underlying the LI-rTMS effect, we verified that BHFS could induce CF reinnervation using our in vitro olivocerebellar explants in which denervated cerebellar tissue is co-cultured adjacent to intact cerebella and treated with brain-derived neurotrophic factor (BDNF) (as a positive control), sham or LI-rTMS for 2 weeks. Compared with sham, BDNF and BHFS LI-rTMS significantly increased CF reinnervation, without additive effect. To identify potential underlying mechanisms, we examined intracellular calcium flux during the 10-min stimulation. Complex high-frequency stimulation increased intracellular calcium by release from intracellular stores. Thus, even at low intensity, rTMS modifies PC structure and induces CF reinnervation.

  7. Low-Intensity Sprint Training With Blood Flow Restriction Improves 100-m Dash.

    Science.gov (United States)

    Behringer, Michael; Behlau, Daniel; Montag, Johannes C K; McCourt, Molly L; Mester, Joachim

    2017-09-01

    Behringer, M, Behlau, D, Montag, JCK, McCourt, ML, and Mester, J. Low-intensity sprint training with blood flow restriction improves 100-m dash. J Strength Cond Res 31(9): 2462-2472, 2017-We investigated the effects of practical blood flow restriction (pBFR) of leg muscles during sprint training on the 100-m dash time in well-trained sport students. Participants performed 6 × 100-m sprints at 60-70% of their maximal 100-m sprinting speed twice a week for 6 weeks, either with (intervention group [IG]; n = 12) or without pBFR (control group [CG]; n = 12). The 100-m dash time significantly decreased more in the IG (-0.38 ± 0.24 seconds) than in the CG (-0.16 ± 0.17 seconds). The muscle thickness of the rectus femoris increased only in the IG, whereas no group-by-time interactions were found for the muscle thickness of the biceps femoris and the biceps brachii. The maximal isometric force, measured using a leg press, did not change in either group. However, the rate of force development improved in the IG. Growth hormone, testosterone, insulin-like growth factor 1, and cortisol concentrations did not significantly differ between both groups at any measurement time point (pre, 1 minute, 20 minutes, 120 minutes, and 24 hours after the 6 all-out sprints of the first training session). The muscle damage marker h-FABP increased significantly more in the CG than in the IG. The pBFR improved the 100-m dash time significantly more than low-intensity sprint interval training alone. Other noted benefits of training with pBFR were a decreased level of muscle damage, a greater increase of the rectus femoris muscle thickness, and a higher rate of force development. However, the tested hormones were unable to explain the additional beneficial effects.

  8. Low-intensity daily walking activity is associated with hippocampal volume in older adults.

    Science.gov (United States)

    Varma, Vijay R; Chuang, Yi-Fang; Harris, Gregory C; Tan, Erwin J; Carlson, Michelle C

    2015-05-01

    Hippocampal atrophy is associated with memory impairment and dementia and serves as a key biomarker in the preclinical stages of Alzheimer's disease. Physical activity, one of the most promising behavioral interventions to prevent or delay cognitive decline, has been shown to be associated with hippocampal volume; specifically increased aerobic activity and fitness may have a positive effect on the size of the hippocampus. The majority of older adults, however, are sedentary and have difficulty initiating and maintaining exercise programs. A modestly more active lifestyle may nonetheless be beneficial. This study explored whether greater objectively measured daily walking activity was associated with larger hippocampal volume. We additionally explored whether greater low-intensity walking activity, which may be related to leisure-time physical, functional, and social activities, was associated with larger hippocampal volume independent of exercise and higher-intensity walking activity. Segmentation of hippocampal volumes was performed using Functional Magnetic Resonance Imaging of the Brain's Software Library (FSL), and daily walking activity was assessed using a step activity monitor on 92, nondemented, older adult participants. After controlling for age, education, body mass index, cardiovascular disease risk factors, and the Mini Mental State Exam, we found that a greater amount, duration, and frequency of total daily walking activity were each associated with larger hippocampal volume among older women, but not among men. These relationships were specific to hippocampal volume, compared with the thalamus, used as a control brain region, and remained significant for low-intensity walking activity, independent of moderate- to vigorous-intensity activity and self-reported exercise. This is the first study, to our knowledge, to explore the relationship between objectively measured daily walking activity and hippocampal volume in an older adult population. Findings

  9. Sustained, Low-Intensity Exercise Achieved by a Dynamic Feeding System Decreases Body Fat in Ponies.

    Science.gov (United States)

    de Laat, M A; Hampson, B A; Sillence, M N; Pollitt, C C

    2016-09-01

    Obesity in horses is increasing in prevalence and can be associated with insulin insensitivity and laminitis. Current treatment strategies for obesity include dietary restriction and exercise. However, whether exercise alone is effective for decreasing body fat is uncertain. Our hypothesis was that twice daily use of a dynamic feeding system for 3 months would induce sustained, low-intensity exercise thereby decreasing adiposity and improving insulin sensitivity (SI). Eight, university-owned, mixed-breed, adult ponies with body condition scores (BCS) ≥5/9 were used. Two treatments ("feeder on" or "feeder off") were administered for a 3-month period by a randomized, crossover design (n = 4/treatment). An interim equilibration period of 6 weeks at pasture separated the 2 study phases. Measurements of body mass (body weight, BCS, cresty neck score [CrNS], and morphometry), body fat (determined before and after the "feeder on" treatment only), triglycerides, and insulin sensitivity (SI; combined glucose-insulin test) were undertaken before and after treatments. The dynamic feeding system induced a 3.7-fold increase in the daily distance travelled (n = 6), compared to with a stationary feeder, which significantly decreased mean BCS (6.53 ± 0.94 to 5.38 ± 1.71), CrNS (2.56 ± 1.12 to 1.63 ± 1.06) and body fat (by 4.95%). An improvement in SI did not occur in all ponies. A dynamic feeding system can be used to induce sustained (daily), low-intensity exercise that promotes weight loss in ponies. However, this exercise may not be sufficient to substantially improve SI. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  10. Low intensity exercise training improves skeletal muscle regeneration potential

    Directory of Open Access Journals (Sweden)

    Tiziana ePietrangelo

    2015-12-01

    Full Text Available Purpose: The aim of this study was to determine whether 12 days of low-to-moderate exercise training at low altitude (598 m a.s.l. improves skeletal muscle regeneration in sedentary adult women.Methods: Satellite cells were obtained from the vastus lateralis skeletal muscle of seven women before and after this exercise training at low altitude. They were investigated for differentiation aspects, superoxide anion production, antioxidant enzymes, mitochondrial potential variation after a depolarizing insult, intracellular Ca2+ concentrations, and micro (miRNA expression (miR-1, miR-133, miR-206.Results: In these myogenic populations of adult stem cells, those obtained after exercise training, showed increased Fusion Index and intracellular Ca2+ concentrations. This exercise training also generally reduced superoxide anion production in cells (by 12% to 67%, although not in two women, where there was an increase of ~15% along with a reduced superoxide dismutase activity. miRNA expression showed an exercise-induced epigenetic transcription profile that was specific according to the reduced or increased superoxide anion production of the cells. Conclusions: The present study shows that low-to-moderate exercise training at low altitude improves the regenerative capacity of skeletal muscle in adult women. The differentiation of cells was favored by increased intracellular calcium concentration and increased the fusion index. This low-to-moderate training at low altitude also depicted the epigenetic signature of cells.

  11. A case-control pilot study of low-intensity IVF in good-prognosis patients.

    Science.gov (United States)

    Gleicher, Norbert; Weghofer, Andrea; Barad, David H

    2012-04-01

    Low-intensity IVF (LI-IVF) is rapidly gaining in popularity. Yet studies comparing LI-IVF to standard IVF are lacking. This is a case-control pilot study, reporting on 14 first LI-IVF and 14 standard IVF cycles in women with normal age-specific ovarian reserve under age 38, matched for age, laboratory environment, staff and time of cycle. LI-IVF cycles underwent mild ovarian stimulation, utilizing clomiphene citrate, augmented by low-dose gonadotrophin stimulation. Control patients underwent routine ovarian stimulation. LI-IVF and regular IVF patients were similar in age, body mass index, FSH and anti-Müllerian hormone. Standard IVF utilized more gonadotrophins (PIVF demonstrated better odds for pregnancy (OR 7.07; P=0.046) and higher cumulative pregnancy rates (63.3% versus 21.4%; OR 6.6; P=0.02). Adjustments for age, ethnicity and diagnosis maintained significance but oocyte adjustment did not. Cost assessments failed to reveal differences between LI-IVF and standard IVF. In this small study, LI-IVF reduced pregnancy chances without demonstrating cost advantages, raising questions about its utility. In the absence of established clinical and/or economic foundations, LI-IVF should be considered an experimental procedure. Low-intensity IVF (LI-IVF) is increasingly propagated as an alternative to standard IVF. LI-IVF has, however, never been properly assessed in comparison to standard IVF. Such a comparison is presented in the format of a small pilot study, matching LI-IVF cycles with regular IVF cycles and comparing outcomes as well as costs. The study suggests that LI-IVF, at least in this setting, is clinically inferior and economically at best similar to standard IVF. LI-IVF should, therefore, as of this point not be offered as routine IVF treatment but only as an experimental procedure. Copyright © 2012 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  12. Increasing the diagnosis of multifocal primary breast cancer by the use of bilateral whole-breast ultrasound

    International Nuclear Information System (INIS)

    Wilkinson, L.S.; Given-Wilson, R.; Hall, T.; Potts, H.; Sharma, A.K.; Smith, E.

    2005-01-01

    AIM: The aim of this study was to evaluate the contribution of bilateral whole-breast ultrasound (BBUS) to the diagnosis and management of women with newly diagnosed breast cancer. METHODS: Over a period of 6 months, 102 women presenting with breast cancer underwent BBUS. Data were collected on clinical findings, radiology, histology and surgical outcome. These women were compared with a control group of 124 women presenting over a similar 6-month period 1 year previously, who had undergone targeted breast ultrasound. RESULTS: Multicentric/multifocal tumours were demonstrated in 35 (34%) of the 102 participants and in 18 (15%) of the 124 controls, a statistically significant difference (Fisher's exact test, p=0.001). Multiple tumours were diagnosed preoperatively in 18% of the study population compared with 8% of the controls, and BBUS identified invasive multifocal/multicentric tumours in significantly more women in the study population (11 versus 1 control) (Fisher's exact test, p=0.019). Contralateral cancer was diagnosed in 4 women in the study population and none in the control population (Fisher's exact test, p=0.040). Surgical review showed that the surgical management changed significantly in 8% (95% confidence interval 4 to 14%) of cases in the study population following BBUS. The increase in the number of women undergoing benign biopsies in the study population (10 versus 5 controls) was not statistically significant (Fisher's exact test, p=0.11). CONCLUSION: BBUS increased the preoperative diagnosis of multiple tumours in women presenting with primary breast cancer, resulting in a management change in 8% of cases

  13. Slope stability improvement using low intensity field electrosmosis

    Science.gov (United States)

    Armillotta, Pasquale

    2014-05-01

    The electrosmosis technique has been introduced in the past for slope stabilization. However, its application to real cases has been scarce due to several drawbacks mostly related to the high intensity electric field needed (1.0 V/cm or higher): the rapid degradation of the electrodes, the high system management cost, the heating and cracking of the soil and the reduction of its colloidal fraction. Thanks to the introduction of new materials, the technique is currently applied to decrease the consolidation time of saturated clay soils (forcing the elimination of water), consequently improving its mechanical strength. In clay soils, the volume variation is influenced by the presence of smectites. The clay compressibility decreases with the increasing of electrolytes concentration. Soil containing smectites that have interacted with calcium showed a reduction or the absence of swelling during hydration with distilled water and a positive increase of their shear strength. The different values of pH between the anode (acid) and the cathode (basic), induced by the electrosmosis create the conditions for the precipitation of CaCO3 near the cathode. The injection of solutions containing calcium in soils and their diffusion induced by the electrosmosis, lead to calcium precipitation and consequential increase of the shear strength. The material technological advances and the laboratory experiences described in this paper, demonstrate that the use low electric field (0.1 V/cm or lower) intensity electrosmosis (LEFE in acronym) can be effective for soil dewatering and shear strength increase while reducing its adverse effect. The LEFE can be used to: reduce the potential for swelling of active clay minerals through the introduction of ions and the precipitation of hardening substances; induce the "dewatering" in cohesive soils. Several Lab activities were carried out, using custom made electrosmosis equipment. These activities can be divided in two phases: Phase 1

  14. Low-intensity shockwave therapy for erectile dysfunction

    DEFF Research Database (Denmark)

    Fode, Mikkel; Hatzichristodoulou, Georgios; Serefoglu, Ege Can

    2017-01-01

    Erectile dysfunction (ED) affects ∼30% of all men above the age of 40 years and its prevalence steadily increases with age. Current nonsurgical treatment options, including phosphodiesterase type 5 inhibitors (PDE5I), provide temporary relief but have failed to provide a permanent improvement...... treatment for ED that might offer a cure, which is the most desired outcome for most men with ED. Li-ESWT has also been suggested to improve the effect of PDE5I in nonresponders, reducing the need for more invasive treatments. Several single-arm trials have shown benefit of Li-ESWT on patient...

  15. Comparação dos efeitos do laser de baixa potência e do ultrassom de baixa intensidade associado ao Biosilicato® no processo de reparo ósseo em tíbias de ratos Comparative study of the effects of low-level laser and low-intensity ultrasound associated with Biosilicate® on the process of bone repair in the rat tibia

    Directory of Open Access Journals (Sweden)

    Poliani de Oliveira

    2012-02-01

    Full Text Available OBJETIVO: Verificar os efeitos da associação do Biosilicato® com o US e com o LLLT no processo de consolidação óssea em ratos, a partir da análise biomecânica e histológica. MÉTODOS: Foram utilizados 40 ratos machos distribuídos em quatro grupos (n = 10: grupo controle fratura sem tratamento (GCF; grupo tratado com Biosilicato® (GB; grupo tratado com Biosilicato® + laser (GBL; grupo tratado com Biosilicato® + US (GBUS. RESULTADOS: A análise biomecânica não apresentou diferença estatisticamente significativa nos grupos após o período experimental de 14 dias. Na análise morfométrica, o grupo controle apresentou presença moderada de tecido ósseo neoformado no interior dos defeitos e o grupo tratado com Biosilicato® apresentou resultados semelhantes. No entanto, foi observado o potencial osteogênico do biomaterial, uma vez que houve grande presença de células e tecido ósseo ao redor das partículas. Interessantemente, os grupos Biosilicato® associado ao laser terapêutico e ao US demonstraram quantidades menores de deposição de tecido ósseo quando comparados aos grupos controle fratura e Biosilicato®. CONCLUSÃO: A partir dos dados deste estudo podemos concluir que o Biosilicato® foi capaz de acelerar e potencializar a recuperação óssea, através da modulação do processo inflamatório e da estimulação da formação de tecido ósseo novo. No entanto, quando a LLLT ou o US foram associados, não foram encontrados resultados positivos.OBJECTIVE: Verify the effects of the association between Biosilicate® and ultrasound and, Biosilicate® and laser in bone consolidation process of rats, through the biomechanical and histological analysis. METHODS: Forthy male rats were used. The animals were randomized into four groups (n=10: control group fracture no treated (CGF; group treated with Biosilicate® (BG; group treated with Biosilicate® and laser (BLG; group treated with Biosilicate® and ultrasound (BUG. RESULTS

  16. Photooptical response of the blood plasma to the low-intensity red light

    International Nuclear Information System (INIS)

    Mints, R.I.; Skopinov, S.A.; Yakovleva, S.V.

    1990-01-01

    Photooptical response to low-intensity red light by irradiation of the whole blood as well as of its pigmentless plasma part is investigated. It is shown by the example of blood irradiation that the mechanism of action of low-intensity red light on the blood is not directly related to pigmented molecular complexes. The conclusion is made, that the effect of low-intensity red light on living organisms includes mechanism not utilizing light absorption by a specialized molecule-photoreceptor as a primary photophysical act

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  18. Effects of the low-intensity red laser radiation on the fluoride uptake in enamel. A clinical trial

    International Nuclear Information System (INIS)

    Nakasone, Regina Keiko

    2004-01-01

    Fluoride has been the most important preventive method on development of the caries. This in vivo study evaluated the effects of low-intensity red laser radiation on the fluoride uptake in enamel. Ten healthy participants were recruited for this study. The two maxillary central incisors of each volunteer to be biopsied were used and divided into 4 groups: group G C (control, which was untreated; group G F (fluoride), which received topical acidulated phosphate fluoride (APF) 1,23% treatment for 4 minutes; group G LF (laser + fluoride), which was irradiated with a low-intensity diode laser (λ= 660 nm and dose= 6 J/cm 2 ) with APF application after irradiation and group G FL (fluoride + laser), which received APF before irradiation using the same parameters as G LF . The determination of fluoride was performed using a fluoride ion electrode after an acid-etch enamel biopsy. The results show a significant increase of the fluoride uptake in enamel for groups G F , G LF and G FL when compared to control group. Although a percentage increase of 57% was observed for G LF with respect to G F , there were no statistical differences among treated groups. These findings suggest that low-intensity laser radiation used before APF could be employed in the clinical practice to prevent dental caries. (author)

  19. Effectiveness of low intensity behavioral treatment for children with autism spectrum disorder and intellectual disability

    NARCIS (Netherlands)

    Peters-Scheffer, N.C.; Didden, H.C.M.; Mulders, M.; Korzilius, H.P.L.M.

    2013-01-01

    To determine the effectiveness of low intensity behavioral treatment (LIBT) supplementing regular treatment in young children with autism spectrum disorder (ASD) and intellectual disability (ID) standardized tests of cognition, adaptive behavior, interpersonal relations, play, language,

  20. Low intensity infrared laser affects expression of oxidative DNA repair genes in mitochondria and nucleus

    International Nuclear Information System (INIS)

    Fonseca, A S; Magalhães, L A G; Mencalha, A L; Geller, M; Paoli, F

    2014-01-01

    Practical properties and physical characteristics of low intensity lasers have made possible their application to treat soft tissue diseases. Excitation of intracellular chromophores by red and infrared radiation at low energy fluences with increase of mitochondrial metabolism is the basis of the biostimulation effect but free radicals can be produced. DNA lesions induced by free radicals are repaired by the base excision repair pathway. In this work, we evaluate the expression of POLγ and APEX2 genes related to repair of mitochondrial and nuclear DNA, respectively. Skin and muscle tissue of Wistar rats were exposed to low intensity infrared laser at different fluences. One hour and 24 hours after laser exposure, tissue samples were withdrawn for total RNA extraction, cDNA synthesis, and evaluation of POLγ and APEX2 mRNA expression by real time quantitative polymerase chain reaction. Skin and muscle tissue of Wistar rats exposed to laser radiation show different expression of POLγ and APEX2 mRNA depending of the fluence and time after exposure. Our study suggests that a low intensity infrared laser affects expression of genes involved in repair of oxidative lesions in mitochondrial and nuclear DNA. (paper)

  1. Impact of aging and comorbidity on the efficacy of low-intensity shock wave therapy for erectile dysfunction.

    Science.gov (United States)

    Hisasue, Shin-ichi; China, Toshiyuki; Horiuchi, Akira; Kimura, Masaki; Saito, Keisuke; Isotani, Shuji; Ide, Hisamitsu; Muto, Satoru; Yamaguchi, Raizo; Horie, Shigeo

    2016-01-01

    To evaluate the efficacy of low-intensity shock wave therapy and to identify the predictive factors of its efficacy in Japanese patients with erectile dysfunction. The present study included 57 patients with erectile dysfunction who satisfied all the following conditions: more than 6-months history of erectile dysfunction, sexual health inventory for men score of ≤ 12 without phosphodiesterase type-5 inhibitor, erection hardness score grade 1 or 2, mean penile circumferential change by erectometer assessing sleep related erection of energy shock waves generator (ED1000; Medispec, Gaithersburg, MD, USA). A total of 12 shock wave treatments were applied. Sexual health inventory for men score, erection hardness score with or without phosphodiesterase type-5 inhibitor, and mean penile circumferential change were assessed at baseline, 1, 3 and 6 months after the termination of low-intensity shock wave therapy. Of 57 patients who were assigned for the low-intensity shock wave therapy trial, 56 patients were analyzed. Patients had a median age of 64 years. The sexual health inventory for men and erection hardness score (with and without phosphodiesterase type-5 inhibitor) were significantly increased (P wave therapy (P wave therapy seems to be an effective physical therapy for erectile dysfunction. Age and comorbidities are negative predictive factors of therapeutic response. © 2015 The Japanese Urological Association.

  2. Benefits of a low intensity exercise programme during haemodialysis sessions in elderly patients

    Directory of Open Access Journals (Sweden)

    Vicent Esteve Simo

    2015-07-01

    Conclusions: (1 An adapted low intensity exercise programme improved muscle strength, functional capacity and health-related quality of life in our elderly patients on HD. (2 Our results highlight the benefits from exercise in HD patients even in this elderly population. (3 In elderly patients on HD, it is worth considering an adapted low intensity intradialytic exercise programme as a part of a comprehensive care.

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  6. Ultrasound -- Pelvis

    Science.gov (United States)

    ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  7. Effects induced by high and low intensity laser plasma on SiC Schottky detectors

    Directory of Open Access Journals (Sweden)

    Sciuto Antonella

    2018-01-01

    Full Text Available Silicon-Carbide detectors are extensively employed as diagnostic devices in laser-generated plasma, allowing the simultaneous detection of photons, electrons and ions, when used in time-of-flight configuration. The plasma generated by high intensity laser (1016 W/cm2 producing high energy ions was characterized by SiC detector with a continuous front-electrode, and a very thick active depth, while SiC detector with an Interdigit front-electrode was used to measure the low energy ions of plasma generated by low intensity laser (1010 W/cm2. Information about ion energy, number of charge states, plasma temperature can be accurately obtained. However, laser exposure induces the formation of surface and bulk defects whose concentration increases with increasing the time to plasma exposure. The surface defects consist of clusters with a main size of the order of some microns and they modify the diode barrier height and the efficiency of the detector as checked by alpha spectrometry. The bulk defects, due to the energy loss of detected ions, strongly affect the electrical properties of the device, inducing a relevant increase of the leakage (reverse current and decrease the forward current related to a deactivation of the dopant in the active detector region.

  8. Effects induced by high and low intensity laser plasma on SiC Schottky detectors

    Science.gov (United States)

    Sciuto, Antonella; Torrisi, Lorenzo; Cannavò, Antonino; Mazzillo, Massimo; Calcagno, Lucia

    2018-01-01

    Silicon-Carbide detectors are extensively employed as diagnostic devices in laser-generated plasma, allowing the simultaneous detection of photons, electrons and ions, when used in time-of-flight configuration. The plasma generated by high intensity laser (1016 W/cm2) producing high energy ions was characterized by SiC detector with a continuous front-electrode, and a very thick active depth, while SiC detector with an Interdigit front-electrode was used to measure the low energy ions of plasma generated by low intensity laser (1010 W/cm2). Information about ion energy, number of charge states, plasma temperature can be accurately obtained. However, laser exposure induces the formation of surface and bulk defects whose concentration increases with increasing the time to plasma exposure. The surface defects consist of clusters with a main size of the order of some microns and they modify the diode barrier height and the efficiency of the detector as checked by alpha spectrometry. The bulk defects, due to the energy loss of detected ions, strongly affect the electrical properties of the device, inducing a relevant increase of the leakage (reverse) current and decrease the forward current related to a deactivation of the dopant in the active detector region.

  9. Design of patient-specific focused ultrasound arrays for non-invasive brain therapy with increased trans-skull transmission and steering range

    Science.gov (United States)

    Hughes, Alec; Hynynen, Kullervo

    2017-09-01

    The use of a phased array of ultrasound transducer elements to sonicate through the skull has opened the way for new treatments and the delivery of therapeutics beyond the blood-brain barrier. The limited steering range of current clinical devices, particularly at higher frequencies, limits the regions of the brain that are considered treatable by ultrasound. A new array design is introduced that allows for high levels of beam steering and increased transmission throughout the brain. These improvements are achieved using concave transducers normal to the outer-skull surface in a patient-specific configuration to target within the skull, so that the far-field of each beam is within the brain. It is shown that by using pulsed ultrasound waves timed to arrive in-phase at the desired target, sufficient levels of acoustic energy are delivered for blood-brain barrier opening throughout the brain.

  10. Commissioning with low-intensity beams helps prepare CMS for this year’s physics run. This event is one of the first low-intensity collisions recorded in the CMS detector, during the early hours of 23 April 2016

    CERN Multimedia

    AUTHOR|(CDS)2068005

    2016-01-01

    Commissioning with low-intensity beams helps prepare CMS for this year’s physics run. This event is one of the first low-intensity collisions recorded in the CMS detector, during the early hours of 23 April 2016

  11. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    Directory of Open Access Journals (Sweden)

    Donghee Park

    Full Text Available Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with

  12. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    Science.gov (United States)

    Park, Donghee; Song, Gillsoo; Jo, Yongjun; Won, Jongho; Son, Taeyoon; Cha, Ohrum; Kim, Jinho; Jung, Byungjo; Park, Hyunjin; Kim, Chul-Woo; Seo, Jongbum

    2016-01-01

    Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa) causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with microbubbles depends on the

  13. P32INCREASED PERCENTAGE RESECTION OF TUMOUR VOLUME USING NEURONAVIGATIONAL 3D INTRAOPERATIVE ULTRASOUND: A SINGLE UNIT EXPERIENCE

    OpenAIRE

    Vaqas, B.; O'Neill, K.; Awad, M.

    2014-01-01

    INTRODUCTION: The use of intraoperative 3D navigational ultrasound (Sonowand) offers a relatively inexpensive method of obtaining imaging of intrinsic brain tumours during resection which takes in account brain shift during surgery and also allows better visualisation of the tumour margin to help control resection. We designed a study to measure the volume of tumour resection in 25 consecutive Sonowand cases compared to 25 matched non-ultrasound guided controls. METHOD: A retrospective consec...

  14. High-Prevalence and Low-Intensity Ichthyophonus Infections in Pacific Halibut.

    Science.gov (United States)

    Hershberger, Paul K; Gregg, Jacob L; Dykstra, Claude L

    2018-03-01

    Ichthyophonus occurred at high prevalence but low intensity in Pacific Halibut Hippoglossus stenolepis throughout the West Coast of North America, ranging from coastal Oregon to the Bering Sea. Infection prevalence in adults was variable on spatial and temporal scales, with the lowest prevalence typically occurring on the edges of the geographic range and highest prevalence consistently occurring inside Prince William Sound, Alaska (58-77%). Additionally, intra-annual differences occurred at Albatross-Portlock, Alaska (71% versus 32% within 2012), and interannual differences occurred along coastal Oregon (50% in 2012 versus 12% in 2015). The infection prevalence was influenced by host age, increasing from 3% or less among the youngest cohorts (age ≤ 6) to 39-54% among age-9-17 cohorts, then decreasing to 27% among the oldest (age-18+) cohorts. There was little indication of significant disease impacts to Pacific Halibut, as the intensity of infection was uniformly low and length at age was similar between infected and uninfected cohorts. These results suggest that Ichthyophonus in Pacific Halibut currently represents a stable parasite-host paradigm in the North Pacific. © 2018 American Fisheries Society.

  15. High prevalence and low intensity Ichthyophonus infections in Pacific Halibut (Hippoglossus stenolepis).

    Science.gov (United States)

    Hershberger, Paul K; Gregg, Jacob L; Dykstra, Claude L

    2017-10-13

    Ichthyophonus occurred at high prevalence but low intensity in Pacific Halibut (Hippoglossus stenolepis) throughout the west coast of North America, ranging from coastal Oregon to the Bering Sea. Infection prevalence in adults was variable on spatial and temporal scales, with the lowest prevalence typically occurring on the edges of the geographic range and highest prevalence consistently occurring inside Prince William Sound, AK (58-77%). Additionally, intra-annual differences occurred at Albatross - Portlock, AK (71% versus 32% within 2012) and inter-annual differences occurred along coastal Oregon (50% versus 12% from 2012 to 2015). The infection prevalence was influenced by host age, increasing from ≤ 3% among the youngest cohorts (≤age 6) to 39-54% among age 9-17 cohorts, then decreasing to 27% among the oldest (age 18+) cohorts. There was little indication of significant disease impacts to Pacific Halibut, as the intensity of infection was uniformly low and length-at-age was similar between infected and uninfected cohorts. These results suggest that Ichthyophonus in Pacific Halibut currently represents a stable parasite-host paradigm in the North Pacific. Received 04 May 2017 accepted 09 Oct 2017 revised 21 Sep 2017.

  16. [Does transcutaneous electrical nerve stimulation or therapeutic ultrasound increase the effectiveness of exercise for knee osteoarthritis: a randomized controlled study].

    Science.gov (United States)

    Eyigör, Sibel; Karapolat, Hale; Ibisoğlu, Uğur; Durmaz, Berrin

    2008-01-01

    The aim of this study was to determine if transcutaneous electrical nerve stimulation (TENS) or therapeutic ultrasound (US) increase the effectiveness of exercise on pain, function, muscle strength and quality of life for knee osteoarthritis (OA). Forty-five patients with primary knee OA diagnosis according to American College Rheumatology criteria were sequentially divided into 3 random groups. The patients in group 1 received TENS (with superficial heat and exercise), group 2 received US (with superficial heat and exercise), and group 3 acted as controls (superficial heat and exercise). Outcome measures were included as visual analog scale (VAS), a 20-meter walking test, Lequesne index, WOMAC scores, isokinetic muscle testing, and the Short Form 36 (SF 36). All treatment groups, physical modalities were carried out for a total fifteen sessions. All of the patients were subjected to six weeks of exercise program. All of the treatment groups had significant improvement on activity VAS, 20 meter walking test, Lequesne index, WOMAC scores, and most of the sub-scores of SF36 when compared with their initial status (p0.05). All of the treatment groups were effective on pain, function, muscle strength and quality of life in patients with knee OA. Statistically significant differences could not be found between the treatment groups. The exercise program, as it is cheaper, more easily performed and efficient, may be preferable for the treatment of knee OA. It is difficult to say, TENS or US could increase the effectiveness of isokinetic exercise for pain, function, muscle strength and quality of life of knee OA in this study.

  17. [Induced thymus aging: radiation model and application perspective for low intensive laser radiation].

    Science.gov (United States)

    Sevost'ianova, N N; Trofimov, A V; Lin'kova, N S; Poliakova, V O; Kvetnoĭ, I M

    2010-01-01

    The influence of gamma-radiation on morphofunctional state of thymus is rather like as natural thymus aging. However gamma-radiation model of thymus aging widely used to investigate geroprotectors has many shortcomings and limitations. Gamma-radiation can induce irreversible changes in thymus very often. These changes are more intensive in comparison with changes, which can be observed at natural thymus aging. Low intensive laser radiation can not destroy structure of thymus and its effects are rather like as natural thymus aging in comparison with gamma-radiation effects. There are many parameters of low intensive laser radiation, which can be changed to improve morphofunctional thymus characteristics in aging model. Using low intensive laser radiation in thymus aging model can be very perspective for investigations of aging immune system.

  18. Echo-lucency of computerized ultrasound images of carotid atherosclerotic plaques are associated with increased levels of triglyceride-rich lipoproteins as well as increased plaque lipid content

    DEFF Research Database (Denmark)

    Grønholdt, Marie-Louise Moes; Nordestgaard, Børge G.; Weibe, Brit M.

    1998-01-01

    carotid plaque echo-lucency and that echo-lucency predicts a high plaque lipid content. Methods and Results-The study included 137 patients with neurological symptoms and greater than or equal to 50% stenosis of the relevant carotid artery, High-resolution B-mode ultrasound images of carotid plaques were......Background-Echo-lucency of carotid atherosclerotic plaques on computerized ultrasound B-mode images has been associated with a high incidence of brain infarcts as evaluated on CT scans. We tested the hypotheses that triglyceride-rich lipoproteins in the fasting and postprandial state predict...

  19. Echolucency of computerized ultrasound images of carotid atherosclerotic plaques are associated with increased levels of triglyceride-rich lipoproteins as well as increased plaque lipid content

    DEFF Research Database (Denmark)

    Grønholdt, Marie-Louise M.; Nordestgaard, Børge; Wiebe, Britt M.

    1998-01-01

    carotid plaque echo-lucency and that echo-lucency predicts a high plaque lipid content. Methods and Results-The study included 137 patients with neurological symptoms and greater than or equal to 50% stenosis of the relevant carotid artery, High-resolution B-mode ultrasound images of carotid plaques were......Background-Echo-lucency of carotid atherosclerotic plaques on computerized ultrasound B-mode images has been associated with a high incidence of brain infarcts as evaluated on CT scans. We tested the hypotheses that triglyceride-rich lipoproteins in the fasting and postprandial state predict...

  20. Low intensity vibration of ankle muscles improves balance in elderly persons at high risk of falling

    Science.gov (United States)

    Toosizadeh, Nima; Mohler, Jane

    2018-01-01

    In our study we examined postural performance of young healthy persons (HY), elderly healthy persons (HE), and elderly persons at high risk of falling (FR). Anterio-posterior (AP) and medio-lateral (ML) ankle and hip angular deviations, as well as linear displacements of the center of mass (COM) were assessed in persons standing with eyes either open or closed, while none, and 40 and 30 Hz vibrations were applied bilaterally to the ankle muscle gastrocnemius. During quiet standing with eyes open, balance parameters in FR group differed from those in healthy groups. ML ankle and hip angular deviations, as well as COM linear displacements were noticeably larger in FR group. During quiet standing with eyes closed, all balance parameters in participants of all groups had a clear trend to increase. During standing with eyes open, 40 Hz vibration increased all but one balance parameter within HY group, ankle angular deviations in HE group, but none in FR group. In response to 30 Hz vibration, only ankle angular deviations and COM linear displacements increased in HY group. There were no changes in both elderly groups. During standing with eyes closed, 40 and 30 Hz vibrations did not produce consistent changes in balance parameters in HY and HE groups. In FR persons, 40 Hz vibration did not change balance parameters. However, in FR groups, 30 Hz vibration decreased ankle and hip angular deviations, and COM linear displacements. The major result of the study is a finding that low intensity vibration of ankle muscles makes balance better in elderly persons at high risk of falling. This result is clinically relevant because it suggests that applying mild vibration to ankle muscles while standing and walking might benefit elderly persons, improving their postural performance and reducing a risk of unexpected falls. PMID:29579098

  1. Low-intensity laser irradiation at 660 nm stimulates cytochrome c oxidase in stressed fibroblast cells.

    Science.gov (United States)

    Houreld, Nicolette N; Masha, Roland T; Abrahamse, Heidi

    2012-07-01

    Low-intensity laser irradiation (LILI) has been used to modulate a variety of biological processes, including diabetic wound healing. The mechanism of action is thought to exist primarily with the mitochondria. This study aimed to determine the effect of irradiation on normal, diabetic, and ischemic mitochondrial electron transport chain (ETC) complexes. Normal, diabetic and ischemic human skin fibroblast mitochondria were irradiated in vitro at a wavelength of 660 nm and a fluence of either 5 or 15 J/cm(2). Non-irradiated mitochondria served as controls. Enzyme activities of mitochondrial complexes I, II, III, and IV were determined immediately post-irradiation. Normal, diabetic, and ischemic cells were irradiated and adenosine triphosphate (ATP) and active mitochondria were determined by luminescence and fluorescent microscopy, respectively. Irradiated diabetic mitochondria at a fluence of 15 J/cm(2) showed a significant decrease in complex III activity (P < 0.05). Normal (P < 0.01) and diabetic (P < 0.05) mitochondria irradiated at either 5 or 15 J/cm(2) showed a significant increase in complex IV activity. ATP results showed a significant increase in irradiated normal cells (5 J/cm(2); P < 0.05) and diabetic cells (15 J/cm(2); P < 0.01). There was a higher accumulation of active mitochondria in irradiated cells than non-irradiated cells. Irradiation at 660 nm has the ability to influence mitochondrial enzyme activity, in particular cytochrome c oxidase. This leads to increased mitochondrial activity and ATP synthesis. Copyright © 2012 Wiley Periodicals, Inc.

  2. Effects of ultrasound on the proliferation and differentiation of cementoblast lineage cells

    NARCIS (Netherlands)

    Inubushi, T.; Tanaka, E.; Rego, E.B.; Kitagawa, M.; Kawazoe, A.; Ohta, A.; Okada, H.; Koolstra, J.H.; Miyauchi, M.; Takata, T.; Tanne, K.

    2008-01-01

    Background: The purpose of this study was to investigate the effects of low-intensity pulsed ultrasound (LIPUS) stimulation on the proliferation and differentiation of cementoblast lineage cells. Methods: An immortalized human periodontal ligament cell line (HPL) showing immature cementoblastic

  3. SU-E-T-245: MR Guided Focused Ultrasound Increased PARP Related Apoptosis On Prostate Cancer in Vivo

    International Nuclear Information System (INIS)

    Chen, L; Chen, X; Cvetkovic, D; Gupta, R; Yang, D; Ma, C

    2014-01-01

    Purpose: Our previous study demonstrated that significant tumor growth delay was observed in the mice treated with pulsed high intensity focused ultrasound (pHIFU). The purpose of this study is to understand the cell killing mechanisms of pHIFU. Methods: Prostate cancer cells (LNCaP), were grown orthotopically in 17 nude mice. Tumor-bearing mice were treated using pHIFU with an acoustic power of 25W, pulse width 100msec and 300 pulses in one sonication under MR guidance. Mutiple sonications were used to cover the whole tumor volume. Temperature (less than 40 degree centigrade in the focal spot) was monitored using MR thermometry. Animals were euthanized at pre-determined time points (n=2) after treatment: 0 hours; 6 hrs; 24 hrs; 48 hrs; 4 days and 7 days. Two tumorbearing mice were used as control. Three tumor-bearing mice were treated with radiation (RT, 2 Gy) using 6 MV photon beams. RT treated mice were euthanized at 0 hr, 6 hrs and 24 hrs. The tumors were processed for immunohistochemical (IHC) staining for PARP (a surrogate of apoptosis). A multispectral imaging analysis system was used to quantify the expression of PARP staining. Cell apoptosis was calculated based on the PARP expression level, which is the intensity of the DAB reaction. Results: Our data showed that PARP related apoptosis peaked at 48 hrs and 7 days in pHIFU treated mice, which is comparable to that for the RT group at 24 hrs. The preliminary results from this study were consistent with our previous study on tumor growth delay using pHIFU. Conclusion: Our results demonstrated that non-thermal pHIFU increased apoptotic tumor cell death through the PARP related pathway. MR guided pHIFU may have a great potential as a safe, noninvasive treatment modality for cancer therapy. This treatment modality might be able to synergize with PARP inhibitors to achieve better result

  4. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  5. Low Intensity Extracorporeal Shock Wave Therapy Improves Erectile Function in a Model of Type II Diabetes Independently of NO/cGMP Pathway.

    Science.gov (United States)

    Assaly-Kaddoum, Rana; Giuliano, François; Laurin, Miguel; Gorny, Diane; Kergoat, Micheline; Bernabé, Jacques; Vardi, Yoram; Alexandre, Laurent; Behr-Roussel, Delphine

    2016-09-01

    Erectile dysfunction is highly prevalent in type II diabetes mellitus. Low intensity extracorporeal shock wave therapy improves erectile function in patients with erectile dysfunction of vasculogenic origin, including diabetes. However, its mode of action remains unknown. We investigated the effects of low intensity extracorporeal shock wave therapy compared to or combined with sildenafil on erectile dysfunction in a type II diabetes mellitus model. Our purpose was to test our hypothesis of a mode of action targeting the cavernous nitric oxide/cyclic guanosine monophosphate pathway. GK rats, a validated model of type II diabetes mellitus, and age matched Wistar rats were treated with low intensity extracorporeal shock wave therapy twice weekly for 3 weeks. Treatment was repeated after a 3-week no-treatment interval. The penis was stretched and dipped in a specifically designed water-filled cage. Shock waves were delivered by a calibrated probe yielding a controlled energy flux density (0.09 mJ/mm(2)). The probe was attached to an electrohydraulic unit with a focused shock wave source, allowing for accurate extrapolation to humans. Following a 4-week washout period erectile function was assessed as well as endothelium dependent and independent, and nitrergic relaxations of the corpus cavernosum of GK rats. Low intensity extracorporeal shock wave therapy significantly improved erectile function in GK rats to the same extent as sildenafil. Treatment effects were potentiated when combined with sildenafil. Shock wave effects were not associated with improved cavernous endothelium dependent or independent, or nitrergic reactivity. Low intensity extracorporeal shock wave therapy improved erectile function in GK rats. Unexpectedly, this was not mediated by a nitric oxide/cyclic guanosine monophosphate dependent mechanism. Sildenafil increased shock wave efficacy. This preclinical paradigm to deliver low intensity extracorporeal shock wave therapy to the rat penis should

  6. THE CYTOTOXIC EFFECTS OF LOW INTENSITY VISIBLE AND INFRARED LIGHT ON HUMAN BREAST CANCER (MCF7 CELLS

    Directory of Open Access Journals (Sweden)

    P Peidaee

    2013-03-01

    Full Text Available A concept of using low intensity light therapy (LILT as an alternative approach to cancer treatment is at early stages of development; while the therapeutic effects of LILT as a non-invasive treatment modality for localized joint and soft tissue wound healing are widely corroborated. The LEDs-based exposure system was designed and constructed to irradiate the selected cancer and normal cells and evaluate the biological effects induced by light exposures in visible and infrared light range. In this study, human breast cancer (MCF7 cells and human epidermal melanocytes (HEM cells (control were exposed to selected far infrared light (3400nm, 3600nm, 3800nm, 3900nm, 4100nm and 4300nm and visible and near infrared wavelengths (466nm, 585nm, 626nm, 810nm, 850nm and 950nm. The optical intensities of LEDs used for exposures were in the range of 15µW to 30µW. Cellular morphological changes of exposed and sham-exposed cells were evaluated using light microscopy. The cytotoxic effects of these low intensity light exposures on human cancer and normal cell lines were quantitatively determined by Lactate dehydrogenase (LDH cytotoxic activity and PrestoBlueTM cell viability assays. Findings reveal that far-infrared exposures were able to reduce cell viability of MCF7 cells as measured by increased LDH release activity and PrestoBlueTM assays. Further investigation of the effects of light irradiation on different types of cancer cells, study of possible signaling pathways affected by electromagnetic radiation (EMR and in vivo experimentation are required in order to draw a firm conclusion about the efficacy of low intensity light as an alternative non-invasive cancer treatment.

  7. Reflecting on mirror mechanisms: motor resonance effects during action observation only present with low-intensity transcranial magnetic stimulation.

    Directory of Open Access Journals (Sweden)

    Michela Loporto

    Full Text Available Transcranial magnetic stimulation (TMS studies indicate that the observation of other people's actions influences the excitability of the observer's motor system. Motor evoked potential (MEP amplitudes typically increase in muscles which would be active during the execution of the observed action. This 'motor resonance' effect is thought to result from activity in mirror neuron regions, which enhance the excitability of the primary motor cortex (M1 via cortico-cortical pathways. The importance of TMS intensity has not yet been recognised in this area of research. Low-intensity TMS predominately activates corticospinal neurons indirectly, whereas high-intensity TMS can directly activate corticospinal axons. This indicates that motor resonance effects should be more prominent when using low-intensity TMS. A related issue is that TMS is typically applied over a single optimal scalp position (OSP to simultaneously elicit MEPs from several muscles. Whether this confounds results, due to differences in the manner that TMS activates spatially separate cortical representations, has not yet been explored. In the current study, MEP amplitudes, resulting from single-pulse TMS applied over M1, were recorded from the first dorsal interosseous (FDI and abductor digiti minimi (ADM muscles during the observation of simple finger abductions. We tested if the TMS intensity (110% vs. 130% resting motor threshold or stimulating position (FDI-OSP vs. ADM-OSP influenced the magnitude of the motor resonance effects. Results showed that the MEP facilitation recorded in the FDI muscle during the observation of index-finger abductions was only detected using low-intensity TMS. In contrast, changes in the OSP had a negligible effect on the presence of motor resonance effects in either the FDI or ADM muscles. These findings support the hypothesis that MN activity enhances M1 excitability via cortico-cortical pathways and highlight a methodological framework by which the

  8. Pulse low-intensity electromagnetic field as prophylaxis of heterotopic ossification in patients with traumatic spinal cord injury

    Directory of Open Access Journals (Sweden)

    Đurović Aleksandar

    2009-01-01

    Full Text Available Background/Aim. Heterotopic ossification (HO is an important complication of head and spinal cord injuries (SCI. Pulse low-intensity electromagnetic field (PLIMF therapy increases blood flow to an area of pain or inflammation, bringing more oxygen to that area and helps to remove toxic substances. The aim of this study was to determine the effect of PLIMF as prophylaxis of HO in patients with SCI. Methods. This prospective random control clinical study included 29 patients with traumatic SCI. The patients were randomly divided into experimental (n = 14 and control group (n = 15. The patients in the experimental group, besides exercise and range of motion therapy, were treated by PLIMF of the following characteristics: induction of 10 mT, frequency of 25 Hz and duration of 30 min. Pulse low-intensity electromagnetic field therapy started in the 7th week after the injury and lasted 4 weeks. The presence or absence of HO around the patients hips we checked by a plane radiography and Brookers classification. Functional capabilities and motor impairment were checked by Functional Independent Measure (FIM, Barthel index and American Spinal Injury Association (ASIA impairment class. Statistic analysis included Kolmogorov-Smirnov test, Shapiro-Wilk test, Mann Whitney Exact test, Exact Wilcoxon signed rank test and Fischer Exact test. Statistical significance was set up to p < 0.05. Results. At the end of the treatment no patient from the experimental group had HO. In the control group, five patients (33.3% had HO. At the end of the treatment the majority of the patients from the experimental group (57.14% moved from ASIA-A to ASIA-B class. Conclusion. Pulse low-intensity electromagnetic field therapy could help as prophylaxis of HO in patients with traumatic SCI.

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are ... Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: pelvic ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Obstetrical Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: ...

  13. A scintillating fibre-based profiler for low intensity ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Finocchiaro, P. [Istituto Nazionale di Fisica Nucleare, Catania (Italy); Amato, A. [Istituto Nazionale di Fisica Nucleare, Catania (Italy); Ciavola, G. [Istituto Nazionale di Fisica Nucleare, Catania (Italy); Cuttone, G. [Istituto Nazionale di Fisica Nucleare, Catania (Italy); Gu, M. [Istituto Nazionale di Fisica Nucleare, Catania (Italy); Raia, G. [Istituto Nazionale di Fisica Nucleare, Catania (Italy); Rovelli, A. [Istituto Nazionale di Fisica Nucleare, Catania (Italy)

    1997-01-11

    In the framework of the EXCYT radioactive ion beam facility, now under development at LNS Catania, we have developed a new beam profile monitor based on a scintillating fibre and a photodetector. Its sensitivity allows the detection of single beam particles in pulse mode, thus representing a useful tool for diagnostics of low and very low intensity beams. (orig.).

  14. A scintillating fibre-based profiler for low intensity ion beams

    International Nuclear Information System (INIS)

    Finocchiaro, P.; Amato, A.; Ciavola, G.; Cuttone, G.; Gu, M.; Raia, G.; Rovelli, A.

    1997-01-01

    In the framework of the EXCYT radioactive ion beam facility, now under development at LNS Catania, we have developed a new beam profile monitor based on a scintillating fibre and a photodetector. Its sensitivity allows the detection of single beam particles in pulse mode, thus representing a useful tool for diagnostics of low and very low intensity beams. (orig.)

  15. Low-intensive proton generators for radiation testing; Nizkointensivnyj protonnyj generator dlya radiatsionnykh ispytanij

    Energy Technology Data Exchange (ETDEWEB)

    Istomin, I V; Gurbich, A F; Semenov, A V

    1994-12-31

    Experiment is conducted and calculations are performed grounding the possibility of creating a low-intensity proton generator based on nuclear reaction. The necessity in such a proton source is defined by the need of conducting long-term testings and by the absence of appropriate equipment.

  16. On the mechanisms of interaction of low-intensity millimeter waves with biological objects

    Energy Technology Data Exchange (ETDEWEB)

    Betskii, O.V.

    1994-07-01

    The interaction of low-intensity millimeter-band electromagnetic waves with biological objects is examined. These waves are widely used in medical practice as a means of physiotherapy for the treatment of various human disorders. Principal attention is given to the mechanisms through which millimeter waves act on the human organism.

  17. Low-intensity infrared lasers alter actin gene expression in skin and muscle tissue

    International Nuclear Information System (INIS)

    Fonseca, A S; Mencalha, A L; Campos, V M A; Ferreira-Machado, S C; Peregrino, A A F; Magalhães, L A G; Geller, M; Paoli, F

    2013-01-01

    The biostimulative effect of low-intensity lasers is the basis for treatment of diseases in soft tissues. However, data about the influence of biostimulative lasers on gene expression are still scarce. The aim of this work was to evaluate the effects of low-intensity infrared lasers on the expression of actin mRNA in skin and muscle tissue. Skin and muscle tissue of Wistar rats was exposed to low-intensity infrared laser radiation at different fluences and frequencies. One and 24 hours after laser exposure, tissue samples were withdrawn for total RNA extraction, cDNA synthesis and evaluation of actin gene expression by quantitative polymerase chain reaction. The data obtained show that laser radiation alters the expression of actin mRNA differently in skin and muscle tissue of Wistar rats depending of the fluence, frequency and time after exposure. The results could be useful for laser dosimetry, as well as to justify the therapeutic protocols for treatment of diseases of skin and muscle tissues based on low-intensity infrared laser radiation. (paper)

  18. Low-intensity red and infrared laser effects at high fluences on Escherichia coli cultures

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, L.L.; Campos, V.M.A.; Magalhaes, L.A.G. [Instituto de Biologia Roberto Alcantara Gomes, Rio de Janeiro, RJ (Brazil). Departamento de Biofisica e Biometria; Paoli, F. [Universidade Federal de Juiz de Fora (UFJF), Juiz de Fora, MG (Brazil). Departamento de Morfologia; Fonseca, A.S., E-mail: adnfonseca@ig.com.br [Universidade Federal do Estado do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Departamento de Ciencias Fisiologicas

    2015-10-15

    Semiconductor laser devices are readily available and practical radiation sources providing wavelength tenability and high monochromaticity. Low-intensity red and near-infrared lasers are considered safe for use in clinical applications. However, adverse effects can occur via free radical generation, and the biological effects of these lasers from unusually high fluences or high doses have not yet been evaluated. Here, we evaluated the survival, filamentation induction and morphology of Escherichia coli cells deficient in repair of oxidative DNA lesions when exposed to low-intensity red and infrared lasers at unusually high fluences. Cultures of wild-type (AB1157), endonuclease III-deficient (JW1625-1), and endonuclease IV-deficient (JW2146-1) E. coli, in exponential and stationary growth phases, were exposed to red and infrared lasers (0, 250, 500, and 1000 J/cm{sup 2}) to evaluate their survival rates, filamentation phenotype induction and cell morphologies. The results showed that low-intensity red and infrared lasers at high fluences are lethal, induce a filamentation phenotype, and alter the morphology of the E. coli cells. Low-intensity red and infrared lasers have potential to induce adverse effects on cells, whether used at unusually high fluences, or at high doses. Hence, there is a need to reinforce the importance of accurate dosimetry in therapeutic protocols. (author)

  19. High or low intensity aerobic fitness training in fibromyalgia: does it matter?

    NARCIS (Netherlands)

    van Santen, Marijke; Bolwijn, Paulien; Landewé, Robert; Verstappen, Frans; Bakker, Carla; Hidding, Alita; van der Kemp, Désirée; Houben, Harry; van der Linden, Sjef

    2002-01-01

    To determine the efficacy of training in fibromyalgia (FM), we compared the effects of high intensity fitness training (HIF) and low intensity fitness training (LIF). Thirty-seven female patients with FM were randomly allocated to either a HIF group (n = 19) or a LIF group (n = 18). Four patients (1

  20. Gravel sediment routing from widespread, low-intensity landscape disturbance, Current River basin, Missouri

    Science.gov (United States)

    Jacobson, Robert B.; Gran, K.B.

    1999-01-01

    During the last 160 years, land-use changes in the Ozarks have had the potential to cause widespread, low-intensity delivery of excess amounts of gravel-sized sediment to stream channels. Previous studies have indicated that this excess gravel bedload is moving in wave-like forms through Ozarks drainage basins. The longitudinal, areal distribution of gravel bars along 160 km of the Current River, Missouri, was evaluated to determine the relative effects of valley-scale controls, tributary basin characteristics, and lagged sediment transport in creating areas of gravel accumulations. The longitudinal distribution of gravel-bar area shows a broad scale wave-like form with increases in gravel-bar area weakly associated with tributary junctions. Secondary peaks of gravel area with 1·8–4·1 km spacing (disturbance reaches) are superimposed on the broad form. Variations in valley width explain some, but not all, of the short-spacing variation in gravel-bar area. Among variables describing tributary drainage basin morphometry, present-day land use and geologic characteristics, only drainage area and road density relate even weakly to gravel-bar areal inventories. A simple, channel network-based sediment routing model shows that many of the features of the observed longitudinal gravel distribution can be replicated by uniform transport of sediment from widespread disturbances through a channel network. These results indicate that lagged sediment transport may have a dominant effect on the synoptic spatial distribution of gravel in Ozarks streams; present-day land uses are only weakly associated with present-day gravel inventories; and valley-scale characteristics have secondary controls on gravel accumulations in disturbance reaches.

  1. Long-Term Low Intensity Physical Exercise Attenuates Heart Failure Development in Aging Spontaneously Hypertensive Rats

    Directory of Open Access Journals (Sweden)

    Luana U. Pagan

    2015-04-01

    Full Text Available Background: Physical exercise is a strategy to control hypertension and attenuate pressure overload-induced cardiac remodeling. The influence of exercise on cardiac remodeling during uncontrolled hypertension is not established. We evaluated the effects of a long-term low intensity aerobic exercise protocol on heart failure (HF development and cardiac remodeling in aging spontaneously hypertensive rats (SHR. Methods: Sixteen month old SHR (n=50 and normotensive Wistar-Kyoto (WKY, n=35 rats were divided into sedentary (SED and exercised (EX groups. Rats exercised in treadmill at 12 m/min, 30 min/day, 5 days/week, for four months. The frequency of HF features was evaluated at euthanasia. Statistical analyses: ANOVA and Tukey or Mann-Whitney, and Goodman test. Results: Despite slightly higher systolic blood pressure, SHR-EX had better functional capacity and lower HF frequency than SHR-SED. Echocardiography and tissue Doppler imaging showed no differences between SHR groups. In SHR-EX, however, left ventricular (LV systolic diameter, larger in SHR-SED than WKY-SED, and endocardial fractional shortening, lower in SHR-SED than WKY-SED, had values between those in WKY-EX and SHR-SED not differing from either group. Myocardial function, assessed in LV papillary muscles, showed improvement in SHR-EX over SHR-SED and WKY-EX. LV myocardial collagen fraction and type I and III collagen gene expression were increased in SHR groups. Myocardial hydroxyproline concentration was lower in SHR-EX than SHR-SED. Lysyl oxidase gene expression was higher in SHR-SED than WKY-SED. Conclusion: Exercise improves functional capacity and reduces decompensated HF in aging SHR independent of elevated arterial pressure. Improvement in functional status is combined with attenuation of LV and myocardial dysfunction and fibrosis.

  2. The effects of low-intensity cycling on cognitive performance following sleep deprivation.

    Science.gov (United States)

    Slutsky, Alexis B; Diekfuss, Jed A; Janssen, James A; Berry, Nate T; Shih, Chia-Hao; Raisbeck, Louisa D; Wideman, Laurie; Etnier, Jennifer L

    2017-10-15

    This study examined the effect of 24h of sleep deprivation on cognitive performance and assessed the effect of acute exercise on cognitive performance following sleep deprivation. Young, active, healthy adults (n=24, 14 males) were randomized to control (age=24.7±3.7years, BMI=27.2±7.0) or exercise (age=25.3±3.3years, BMI=25.6±5.1) groups. Cognitive testing included a 5-min psychomotor vigilance task (PVT), three memory tasks with increasing cognitive load, and performance of the PVT a second time. On morning one, cognitive testing followed a typical night's sleep. Following 24-h of sustained wakefulness, cognitive testing was conducted again prior to and after the acute intervention. Participants in the exercise condition performed low-intensity cycling (∼40%HRR) for 15-min and those in the control condition sat quietly on the bike for 15-min. t-Tests revealed sleep deprivation negatively affected performance on the PVT, but did not affect memory performance. Following the acute intervention, there were no cognitive performance differences between the exercise and rested conditions. We provide support for previous literature suggesting that during simple tasks, sleep deprivation has negative effects on cognitive performance. Importantly, in contrast to previous literature which has shown multiple bouts of exercise adding to cognitive detriment when combined with sleep deprivation, our results did not reveal any further detriments to cognitive performance from a single-bout of exercise following sleep deprivation. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Low Intensity Shock Wave Treatment for Erectile Dysfunction-How Long Does the Effect Last?

    Science.gov (United States)

    Kitrey, Noam D; Vardi, Yoram; Appel, Boaz; Shechter, Arik; Massarwi, Omar; Abu-Ghanem, Yasmin; Gruenwald, Ilan

    2018-03-01

    We studied the long-term efficacy of penile low intensity shock wave treatment 2 years after an initially successful outcome. Men with a successful outcome of low intensity shock wave treatment according to the minimal clinically important difference on the IIEF-EF (International Index of Erectile Function-Erectile Function) questionnaire were followed at 6, 12, 18 and 24 months. Efficacy was assessed by the IIEF-EF. Failure during followup was defined as a decrease in the IIEF-EF below the minimal clinically important difference. We screened a total of 156 patients who underwent the same treatment protocol but participated in different clinical studies. At 1 month treatment was successful in 99 patients (63.5%). During followup a gradual decrease in efficacy was observed. The beneficial effect was maintained after 2 years in only 53 of the 99 patients (53.5%) in whom success was initially achieved. Patients with severe erectile dysfunction were prone to earlier failure than those with nonsevere erectile dysfunction. During the 2-year followup the effect of low intensity shock wave treatment was lost in all patients with diabetes who had severe erectile dysfunction at baseline. On the other hand, patients with milder forms of erectile dysfunction without diabetes had a 76% chance that the beneficial effect of low intensity shock wave treatment would be preserved after 2 years. Low intensity shock wave treatment is effective in the short term but treatment efficacy was maintained after 2 years in only half of the patients. In patients with milder forms of erectile dysfunction the beneficial effect is more likely to be preserved. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. Impacts of sugarcane agriculture expansion over low-intensity cattle ranch pasture in Brazil on greenhouse gases.

    Science.gov (United States)

    Bento, Camila Bolfarini; Filoso, Solange; Pitombo, Leonardo Machado; Cantarella, Heitor; Rossetto, Raffaella; Martinelli, Luiz Antonio; do Carmo, Janaina Braga

    2018-01-15

    Sugarcane is a widespread bioenergy crop in tropical regions, and the growing global demand for renewable energy in recent years has led to a dramatic expansion and intensification of sugarcane agriculture in Brazil. Currently, extensive areas of low-intensity pasture are being converted to sugarcane, while management in the remaining pasture is becoming more intensive, i.e., includes tilling and fertilizer use. In this study, we assessed how such changes in land use and management practices alter emissions of greenhouse gases (GHG) such as CO 2 , N 2 O and CH 4 by measuring in situ fluxes for one year after conversion from low-intensity pasture to conventional sugarcane agriculture and management-intensive pasture. Results show that CO 2 and N 2 O fluxes increased significantly in pasture and sugarcane with tillage, fertilizer use, or both combined. Emissions were highly variable for all GHGs, yet, cumulatively, it was clear that annual emissions in CO 2 -equivalent (CO 2 -eq) were higher in management-intense pasture and sugarcane than in unmanaged pasture. Surprisingly, tilled pasture with fertilizer (management-intensive pasture) resulted in higher CO 2 -eq emissions than conventional sugarcane. We concluded that intensification of pasture management and the conversion of pasture to sugarcane can increase the emission factor (EF) estimated for sugarcane produced in Brazil. The role of management practices and environmental conditions and the potential for reducing emissions are discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  6. Post-processing of polymer foam tissue scaffolds with high power ultrasound: A route to increased pore interconnectivity, pore size and fluid transport

    International Nuclear Information System (INIS)

    Watson, N.J.; Johal, R.K.; Glover, Z.; Reinwald, Y.; White, L.J.; Ghaemmaghami, A.M.; Morgan, S.P.; Rose, F.R.A.J.; Povey, M.J.W.; Parker, N.G.

    2013-01-01

    The aim of this work is to demonstrate that the structural and fluidic properties of polymer foam tissue scaffolds, post-fabrication but prior to the introduction of cells, can be engineered via exposure to high power ultrasound. Our analysis is supported by measurements of fluid uptake during insonification and imaging of the scaffold microstructure via X-ray computed tomography, scanning electron microscopy and acoustic microscopy. The ultrasonic treatment is performed with a frequency of 30 kHz, average intensities up to 80,000 Wm −2 and exposure times up to 20 h. The treatment is found to increase the mean pore size by over 10%. More striking is the improvement in fluid uptake: for scaffolds with only 40% water uptake via standard immersion techniques, we can routinely achieve full saturation of the scaffold over approximately one hour of exposure. These desirable modifications occur with negligible loss of scaffold integrity and mass, and are optimized when the ultrasound treatment is coupled to a pre-wetting stage with ethanol. Our findings suggest that high power ultrasound is highly targeted towards flow obstructions in the scaffold architecture, thereby providing an efficient means to promote pore interconnectivity and fluid transport in thick foam tissue scaffolds. - Highlights: • We expose thick PLA foam tissue scaffolds to high power ultrasound. • This treatment both accelerates and enhances the uptake of fluid into the scaffold. • It leads to significant increases in the mean pore size, pore interconnectivity and porosity. • The ultrasonic treatment is most effective when the scaffold is pre-wet with ethanol. • We demonstrate the use of acoustic microscopy to characterize the scaffold microstructure

  7. Synergistic effects of low-intensity exercise conditioning and β-blockade on cardiovascular and autonomic adaptation in pre- and postmenopausal women with hypertension.

    Science.gov (United States)

    Goldie, Catherine L; Brown, C Ann; Hains, Sylvia M J; Parlow, Joel L; Birtwhistle, Richard

    2013-10-01

    The effects of a 12-week low-intensity exercise conditioning program (walking) on blood pressure (BP), heart rate (HR), rate-pressure product (RPP), and cardiac autonomic function were measured in 40 sedentary women with hypertension. Women were assigned to either an exercise group (n = 20) or a control group (n = 20), matched for β-blockade treatment. They underwent testing at the beginning and at the end of the 12-week study period in three conditions: supine rest, standing, and low-intensity steady state exercise. The exercise group participated in a 12-week, low-intensity walking program, while the control group continued with usual sedentary activity. Compared with the control group, women in the exercise group showed reductions in systolic and diastolic BP and RPP (i.e., the estimated cardiac workload). β-Blockers increased baroreflex sensitivity and lowered BP and HR in all participants; however, those in the exercise group showed the effects of both treatments: a greater reduction in HR and RPP. The combination of exercise training and β-blockade produces cardiac and autonomic adaptations that are not observed with either treatment alone, suggesting that β-blockade enhances the conditioning effects of low-intensity exercise in women with hypertension.

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  10. [The application of low-intensity electromagnetic radiation under immobilization stress conditions (an experimental study)].

    Science.gov (United States)

    Korolev, Iu N; Bobrovnitskiĭ, I P; Nikoulina, L A; Mikhaĭlik, L V; Geniatulina, M S; Bobkova, A S

    2014-01-01

    The experiments carried out on outbred male white rats with the use of optical, electron-microscopic, biochemical, and radioimmunological methods have demonstrated that the application of low-intensity electromagnetic radiation (LI-EMR) with a flow density of 1 mcW/cm2 and a frequency of around 1,000 MHz both in the primary prophylaxis regime and as the therapeuticpreventive modality arrested the development of post-stress disorders in the rat testicles, liver, and thymus; moreover, it promoted activation of the adaptive, preventive, and compensatory processes. The data obtained provide a rationale for the application of low-intensity electromagnetic radiation to protect the organism from negative effects of stressful factors.

  11. Early phase interference between low-intensity running and power training in moderately trained females

    DEFF Research Database (Denmark)

    Terzis, Gerasimos; Spengos, Kostas; Methenitis, Spyros

    2016-01-01

    PURPOSE: The aim of the study was to investigate the effects of low-intensity running performed immediately after lower-body power-training sessions on power development. METHODS: Twenty young females participated in 6 weeks, 3/week, of either lower body power training (PT) or lower body power...... training followed by 30 min of low-intensity running (PET) eliciting 60-70 % of maximal heart rate. The following were measured before and after the training period: counter-movement jump, isometric leg press force and rate of force development (RFD), half squat 1-RM, vastus lateralis fiber type...... performed after lower-body power training impairs the exercise-induced adaptation in stretch-shortening cycle jumping performance (vertical jump height, peak power), during the first 6 weeks of training, which may be partially linked to inhibited muscle fiber hypertrophy and muscle fiber conduction velocity....

  12. A new influence model of low intensive ionizing radiation on organism

    International Nuclear Information System (INIS)

    Bulanova, K.Ya.; Lobanok, L.M.; Berdnikov, M.V.; Ignatenko, A.O.; Konoplya, E.F.

    2006-01-01

    The data and facts about the influence of ionizing radiation in small doses and low intensity on cardiovascular system and blood sells of experimental animals are given in the article. The ideas about its signal perception are used to illustrate and explain the mechanisms of low intensive physical nature factors influencing on organism. The leading role of quantitative information change in the process of forming physiological and pathologic influence of radiation on organism is supposed. The influence of X-ray small doses emission on human organism was analyzed on the basis of entropy calculation with the help of mathematical conversion characteristic of finger-tips luminosity. This method helped us to understand that the amount of information in the system was changed during post-radiation period. (authors)

  13. High-effective position time spectrometer in actual measurements of low intensity region of electron spectra

    International Nuclear Information System (INIS)

    Babenkov, M.I.; Zhdanov, V.S.

    2002-01-01

    Magnetic position-time spectrometer was proposed in previous work, where not only electron coordinates in focal plane are measured by position sensitive detector (PSD) but places of their birth in beta source plane of a large area are fixed using another PSD, situated behind it, by quick effects, accompanying radioactive decay. PSD on the basis of macro-channel plates are used. It is succeeded in position-time spectrometer to combine beta sources of a large area with multichannel registration for a wide energy interval, that efficiency of measurements was two orders of magnitude increase d in comparison magnetic apparatus having PSD only in focal plane. Owing to two detectors' switching on coincidence the relation effect/background in increased minimum on two orders of magnitude in comparison with the same apparatus. At some complication of mathematical analysis it was obtained, that high characteristics of position-time spectrometer are kept during the use the magnetic field, providing double focusing. Owning to this focusing the gain the efficiency of measurements will make one more order of magnitude. Presented high-effective position-time spectrometer is supposed to use in the measurements of low-intensity region of electron spectra, which are important for development of fundamental physics. This is the first of all estimation of electron anti-neutrino mass by the form of beta spectrum of tritium in the region of boundary energy. Recently here there was problem of non physical negative values. This problem can be solved by using in measurement of different in principle high-effective spectrometers, which possess improved background properties. A position-time spectrometers belongs to these apparatus, which provides the best background conditions at very large effectiveness of the measurements of tritium beta spectrum in the region of boundary energy with acceptable high resolution. An important advantage of position-time spectrometer is the possibility of

  14. The Misplaced Ruse: Strategic Military Deception as a Tool in Low-Intensity Conflict

    Science.gov (United States)

    2016-05-20

    potential in not just low-intensity conflict but in warfare in general. Levels of War Tactical 6 JP 1-02, Department of Defense (DoD) Dictionary of...number of other objects and “ pocket litter” that would lend credibility and legitimacy to the character and identity of the body. These things...included a ticket stub from a movie theater, receipts from various stores, and other personal belongings that one may have in their pocket and forget

  15. DNA fragmentation and nuclear phenotype in tendons exposed to low-intensity infrared laser

    Science.gov (United States)

    de Paoli, Flavia; Ramos Cerqueira, Larissa; Martins Ramos, Mayara; Campos, Vera M.; Ferreira-Machado, Samara C.; Geller, Mauro; de Souza da Fonseca, Adenilson

    2015-03-01

    Clinical protocols are recommended in device guidelines outlined for treating many diseases on empirical basis. However, effects of low-intensity infrared lasers at fluences used in clinical protocols on DNA are controversial. Excitation of endogenous chromophores in tissues and free radicals generation could be described as a consequence of laser used. DNA lesions induced by free radicals cause changes in DNA structure, chromatin organization, ploidy degrees and cell death. In this work, we investigated whether low-intensity infrared laser therapy could alter the fibroblasts nuclei characteristics and induce DNA fragmentation. Tendons of Wistar rats were exposed to low-intensity infrared laser (830 nm), at different fluences (1, 5 and 10 J/cm2), in continuous wave (power output of 10mW, power density of 79.6 mW/cm2). Different frequencies were analyzed for the higher fluence (10 J/cm2), at pulsed emission mode (2.5, 250 and 2500 Hz), with the laser source at surface of skin. Geometric, densitometric and textural parameters obtained for Feulgen-stained nuclei by image analysis were used to define nuclear phenotypes. Significant differences were observed on the nuclear phenotype of tendons after exposure to laser, as well as, high cell death percentages was observed for all fluences and frequencies analyzed here, exception 1 J/cm2 fluence. Our results indicate that low-intensity infrared laser can alter geometric, densitometric and textural parameters in tendon fibroblasts nuclei. Laser can also induce DNA fragmentation, chromatin lost and consequently cell death, using fluences, frequencies and emission modes took out from clinical protocols.

  16. Study on low intensity aeration oxygenation model and optimization for shallow water

    Science.gov (United States)

    Chen, Xiao; Ding, Zhibin; Ding, Jian; Wang, Yi

    2018-02-01

    Aeration/oxygenation is an effective measure to improve self-purification capacity in shallow water treatment while high energy consumption, high noise and expensive management refrain the development and the application of this process. Based on two-film theory, the theoretical model of the three-dimensional partial differential equation of aeration in shallow water is established. In order to simplify the equation, the basic assumptions of gas-liquid mass transfer in vertical direction and concentration diffusion in horizontal direction are proposed based on engineering practice and are tested by the simulation results of gas holdup which are obtained by simulating the gas-liquid two-phase flow in aeration tank under low-intensity condition. Based on the basic assumptions and the theory of shallow permeability, the model of three-dimensional partial differential equations is simplified and the calculation model of low-intensity aeration oxygenation is obtained. The model is verified through comparing the aeration experiment. Conclusions as follows: (1)The calculation model of gas-liquid mass transfer in vertical direction and concentration diffusion in horizontal direction can reflect the process of aeration well; (2) Under low-intensity conditions, the long-term aeration and oxygenation is theoretically feasible to enhance the self-purification capacity of water bodies; (3) In the case of the same total aeration intensity, the effect of multipoint distributed aeration on the diffusion of oxygen concentration in the horizontal direction is obvious; (4) In the shallow water treatment, reducing the volume of aeration equipment with the methods of miniaturization, array, low-intensity, mobilization to overcome the high energy consumption, large size, noise and other problems can provide a good reference.

  17. The Saturne beam measurement system for orbit corrections and high and low intensity beam acceleration

    International Nuclear Information System (INIS)

    Degueurce, L.; Nakach, A.; Sole, J.

    1980-07-01

    This paper summarizes the dipolar and multipolar correction system and the main beam diagnostics of Saturne II: wide-band RF electrostatic pick-up electrode for observation of bunches, beam position and tune measurement systems, special electrodes for observation of emittance blow-up when particles cross a resonance line. For low intensity beams, special electrodes and electronics have been developed. All this instrumentation is computer controlled

  18. A study of the effect of low intensity laser therapy on the osseointegration of hydroxyapatite implants

    International Nuclear Information System (INIS)

    Rajab, A.A.

    1999-01-01

    Three significant developments over the last decade in the maxillofacial region have been the predictable use of dental implants, the employment of hydroxyapatite as an implant coating, with a potential for more rapid osseointegration, and the introduction of Low Intensity Laser Therapy (LILT) for the enhancement of healing. Implants, although proving a major advance in prosthetics have the disadvantage that loading has to be delayed for a period, which in the case of the mouth needs to be 3 - 6 months after insertion. Hydroxyapatite offers the possibility of a shortened period of delay. Low Intensity Laser Therapy (LILT) has been shown to accelerate the healing of bony fractures, both experimentally and clinically. This thesis sets out to evaluate whether LILT could enhance the process of osseointegration, particularly when used with ceramic hydroxyapatite implants in an animal model. If so, this could provide a future clinical combination which would allow earlier loading of hydroxyapatite coated dental implants and also their counterparts in femoral head replacement. There has been virtually no research work undertaken on this aspect. An animal research study has been undertaken to investigate the effect of LILT on the osseointegration of endosseous implants. HA ceramic implants were inserted in two different anatomical sites, namely the mandible and femur in 40 rabbits. The animals were divided into three groups, comprising a low energy laser group (25 J/cm 2 per treatment), a high energy group (125 J/cm 2 per treatment ) and a control group. Animals were sacrificed at four and twelve weeks, with equivalent numbers of representatives of the three groups. The evolved method of evaluation involved radiographic methods (plain x-ray, radiovisiography RVG and the innovative technique of x-ray microtomography XMT), mechanical push out testing (Instron machine) and histological examination (qualitative and quantitative histomorphometry). The conclusions of the study

  19. Low-intensity red and infrared lasers on XPA and XPC gene expression

    International Nuclear Information System (INIS)

    Fonseca, A S; Magalhães, L A G; Mencalha, A L; Ferreira-Machado, S C; Geller, M; Paoli, F

    2014-01-01

    Laser devices emit monochromatic, coherent, and highly collimated intense beams of light that are useful for a number of biomedical applications. However, for low-intensity lasers, possible adverse effects of laser light on DNA are still controversial. In this work, the expression of XPA and XPC genes in skin and muscle tissue exposed to low-intensity red and infrared lasers was evaluated. Skin and muscle tissue of Wistar rats were exposed to low-intensity red and infrared lasers at different fluences in continuous mode emission. Skin and muscle tissue samples were withdrawn for total RNA extraction, cDNA synthesis, and evaluation of actin gene expression by quantitative polymerase chain reaction. Data obtained show that laser radiation alters the expression of XPA and XPC mRNA differently in skin and muscle tissue of Wistar rats, depending on physical (fluence and wavelength) and biological (tissue) parameters. Laser light could modify expression of genes related to the nucleotide excision repair pathway at fluences and wavelengths used in clinical protocols. (letter)

  20. Mitigating cutaneous sensation differences during tDCS: comparing sham versus low intensity control conditions.

    Science.gov (United States)

    Brunyé, Tad T; Cantelon, Julie; Holmes, Amanda; Taylor, Holly A; Mahoney, Caroline R

    2014-01-01

    Cutaneous sensations at electrode sites during the administration of direct current brain stimulation may inadvertently influence participants' subjective experience and task performance. The present study evaluated the utility of a methodological variation that substitutes sham administration with very low intensity (0.5 mA) current delivery. We used a 4 × 1 high-definition ring electrode transcranial direct current (HD-tDCS) system to target the left dorsolateral prefrontal cortex (Brodmann's Area 9). Four stimulation conditions were compared in a repeated-measures design: sham 2.0 mA and 0.5 mA intensity, versus active 2.0 mA and 0.5 mA intensity. During stimulation participants performed a cognitive interference task that activates the cingulo-frontal-parietal network, and periodically provided perceived sensation ratings. We demonstrate that a relatively low intensity control condition attenuates otherwise large differences in perceived sensation between active and sham conditions. Critically, behavioral task differences maintained between the two active conditions. A low intensity control stimulation condition may prove a viable methodological alternative to conventional sham techniques used in repeated-measures designs, though important limitations are discussed. Published by Elsevier Inc.

  1. Repeated prolonged whole-body low-intensity exercise: effects on insulin sensitivity and limb muscle adaptations

    DEFF Research Database (Denmark)

    Helge, Jørn Mikael; Overgaard, Kristian; Damsgaard, Rasmus

    2006-01-01

    arbitrary units) than in the arm (54 ± 9 arbitrary units) and was not changed in the leg, but was increased (P increased glucose transporter expression in arm muscle may compensate for the loss of lean body mass...... or body mass, were not affected by the crossing. Citrate synthase activity was higher (P muscle (16 ± 2 µmol · g-1 · min-1) and was unchanged after the crossing. Muscle GLUT4 protein concentration was higher (P ...This study investigates the effect of prolonged whole-body low-intensity exercise on insulin sensitivity and the limb muscle adaptive response. Seven male subjects (weight, 90.2 ± 3.2 kg; age, 35 ± 3 years) completed a 32-day unsupported crossing of the Greenland icecap on cross-country skies...

  2. In vitro magnetic stimulation: a simple stimulation device to deliver defined low intensity electromagnetic fields

    Directory of Open Access Journals (Sweden)

    Stephanie Grehl

    2016-11-01

    Full Text Available Non-invasive electromagnetic field brain stimulation (NIBS appears to benefit human neurological and psychiatric conditions, although the optimal stimulation parameters and underlying mechanisms remain unclear. Although in vitro studies have begun to elucidate cellular mechanisms, stimulation is delivered by a range of coils (from commercially available human stimulation coils to laboratory-built circuits so that the electromagnetic fields induced within the tissue to produce the reported effects are ill-defined.Here we develop a simple in vitro stimulation device with plug-and-play features that allow delivery of a range of stimulation parameters. We chose to test low intensity repetitive magnetic stimulation (LI-rMS delivered at 3 frequencies to hindbrain explant cultures containing the olivocerebellar pathway. We used computational modelling to define the parameters of a stimulation circuit and coil that deliver a unidirectional homogeneous magnetic field of known intensity and direction, and therefore a predictable electric field, to the target. We built the coil to be compatible with culture requirements: stimulation within an incubator; a flat surface allowing consistent position and magnetic field direction; location outside the culture plate to maintain sterility and no heating or vibration. Measurements at the explant confirmed the induced magnetic field was homogenous and matched the simulation results. To validate our system we investigated biological effects following LI-rMS at 1 Hz, 10 Hz and biomimetic high frequency (BHFS, which we have previously shown induces neural circuit reorganisation. We found that gene expression was modified by LI-rMS in a frequency-related manner. Four hours after a single 10-minute stimulation session, the number of c-fos positive cells increased, indicating that our stimulation activated the tissue. Also, after 14 days of LI-rMS, the expression of genes normally present in the tissue was differentially

  3. Low intensity exercise prevents disturbances in rat cardiac insulin signaling and endothelial nitric oxide synthase induced by high fructose diet.

    Science.gov (United States)

    Stanišić, Jelena; Korićanac, Goran; Ćulafić, Tijana; Romić, Snježana; Stojiljković, Mojca; Kostić, Milan; Pantelić, Marija; Tepavčević, Snežana

    2016-01-15

    Increase in fructose consumption together with decrease in physical activity contributes to the development of metabolic syndrome and consequently cardiovascular diseases. The current study examined the preventive role of exercise on defects in cardiac insulin signaling and function of endothelial nitric oxide synthase (eNOS) in fructose fed rats. Male Wistar rats were divided into control, sedentary fructose (received 10% fructose for 9 weeks) and exercise fructose (additionally exposed to low intensity exercise) groups. Concentration of triglycerides, glucose, insulin and visceral adipose tissue weight were determined to estimate metabolic syndrome development. Expression and/or phosphorylation of cardiac insulin receptor (IR), insulin receptor substrate 1 (IRS1), tyrosine-specific protein phosphatase 1B (PTP1B), Akt, extracellular signal-regulated protein kinases 1 and 2 (ERK1/2) and eNOS were evaluated. Fructose overload increased visceral adipose tissue, insulin concentration and homeostasis model assessment index. Exercise managed to decrease visceral adiposity and insulin level and to increase insulin sensitivity. Fructose diet increased level of cardiac PTP1B and pIRS1 (Ser307), while levels of IR and ERK1/2, as well as pIRS1 (Tyr 632), pAkt (Ser473, Thr308) and pERK1/2 were decreased. These disturbances were accompanied by reduced phosphorylation of eNOS at Ser1177. Exercise managed to prevent most of the disturbances in insulin signaling caused by fructose diet (except phosphorylation of IRS1 at Tyr 632 and phosphorylation and protein expression of ERK1/2) and consequently restored function of eNOS. Low intensity exercise could be considered as efficient treatment of cardiac insulin resistance induced by fructose diet. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Low-intensity aerobic exercise training: inhibition of skeletal muscle atrophy in high-fat-diet-induced ovariectomized rats.

    Science.gov (United States)

    Kim, Hye Jin; Lee, Won Jun

    2017-09-30

    Postmenopausal women are highly susceptible to diseases, such as obesity, type 2 diabetes, osteoporosis, or skeletal muscle atrophy and many people recognize the need for regular physical activity. Aerobic exercise training is known to improve the oxidative capacity and insulin sensitivity of skeletal muscles. This study aimed to investigate the role of low-intensity aerobic exercise training on skeletal muscle protein degradation or synthesis in the plantaris muscles of high-fat-fed ovariectomized rats. Ovariectomized female rats were divided into two groups: a high-fat diet-sedentary group (HFD), and a high-fat diet-aerobic exercise group (HFD+EX). The exercise group exercised aerobically on a treadmill 5 days/week for 8 weeks. The rats progressively ran 30 min/day at 15 m/min, up to 40 min/day at 18 m/min, 0% slope, in the last 4 weeks. Although aerobic exercise led to significantly increased AMP-activated protein kinase (AMPK) phosphorylation at Thr172, phosphorylation of the mammalian target of rapamycin (mTOR) substrate Thr389 S6K1 level did not decrease. Additionally, even though Akt activity did not increase at Ser473, the atrogin-1 level significantly decreased in the exercise group compared to the non-exercise group. Immunohistochemical staining revealed that high-fat-induced TSC2 protein expression was eliminated in response to aerobic exercise. These results suggest that aerobic exercise can inhibit skeletal muscle protein degradation, but it cannot increase protein synthesis in the plantaris muscle of high-fat-fed ovariectomized rats. Our findings have implications in understanding skeletal muscle mass maintenance with low intensity aerobic exercise in post-menopausal women. ©2017 The Korean Society for Exercise Nutrition

  5. Children, Learning and Chronic Natural Disasters: How Does the Government of Dominica Address Education during Low-Intensity Hurricanes?

    Science.gov (United States)

    Serrant, Ted Donaldson

    2013-01-01

    By the time today's Grade K students graduate high school in the Commonwealth of Dominica, they will have experienced five major and many low-intensity hurricanes (LIH). Between August and November each year, each hurricane, major or low-intensity, represents a major threat to their safety and schooling. This mixed-method case study investigated…

  6. Hormone Responses to an Acute Bout of Low Intensity Blood Flow Restricted Resistance Exercise in College-Aged Females

    Directory of Open Access Journals (Sweden)

    Eonho Kim

    2014-03-01

    Full Text Available The purpose of this study was to determine whether the acute hormone response to exercise differed between low intensity blood flow restricted resistance exercise and traditional high-intensity resistance exercise in college-aged women. A total of 13 healthy women (aged 18-25 yrs, who were taking oral contraceptives, volunteered for this randomized crossover study. Subjects performed a session of low intensity blood flow restricted resistance exercise (BFR (20% of 1-RM, 1 set 30 reps, 2 sets 15 reps and a session of traditional high intensity resistance exercise without blood flow restriction (HI (3 sets of 10 repetitions at 80% of 1-RM on separate days. Fasting serum cortisol and growth hormone (GH and blood lactate responses were measured in the morning pre and post exercise sessions. GH (Change: HI: 6.34 ± 1.72; BFR: 4.22 ± 1.40 ng·mL-1 and cortisol (Change: HI: 4.46 ± 1.53; BFR: 8.10 ± 2.30 ug·dL-1 significantly (p < 0.05 increased immediately post exercise for both protocols compared to baseline and there were no significant differences between the protocols for these responses. In contrast, blood lactate levels (HI: 7.35 ± 0.45; BFR: 4.02 ± 0.33 mmol·L-1 and ratings of perceived exertion were significantly (p < 0.01 higher for the HI protocol. In conclusion, acute BFR restricted resistance exercise stimulated similar increases in anabolic and catabolic hormone responses in young women.

  7. Bioenergy from Low-Intensity Agricultural Systems: An Energy Efficiency Analysis

    Directory of Open Access Journals (Sweden)

    Oludunsin Arodudu

    2016-12-01

    Full Text Available In light of possible future restrictions on the use of fossil fuel, due to climate change obligations and continuous depletion of global fossil fuel reserves, the search for alternative renewable energy sources is expected to be an issue of great concern for policy stakeholders. This study assessed the feasibility of bioenergy production under relatively low-intensity conservative, eco-agricultural settings (as opposed to those produced under high-intensity, fossil fuel based industrialized agriculture. Estimates of the net energy gain (NEG and the energy return on energy invested (EROEI obtained from a life cycle inventory of the energy inputs and outputs involved reveal that the energy efficiency of bioenergy produced in low-intensity eco-agricultural systems could be as much as much as 448.5–488.3 GJ·ha−1 of NEG and an EROEI of 5.4–5.9 for maize ethanol production systems, and as much as 155.0–283.9 GJ·ha−1 of NEG and an EROEI of 14.7–22.4 for maize biogas production systems. This is substantially higher than for industrialized agriculture with a NEG of 2.8–52.5 GJ·ha−1 and an EROEI of 1.2–1.7 for maize ethanol production systems, as well as a NEG of 59.3–188.7 GJ·ha−1 and an EROEI of 2.2–10.2 for maize biogas production systems. Bioenergy produced in low-intensity eco-agricultural systems could therefore be an important source of energy with immense net benefits for local and regional end-users, provided a more efficient use of the co-products is ensured.

  8. Untreated runoff quality from roof and road surfaces in a low intensity rainfall climate.

    Science.gov (United States)

    Charters, Frances J; Cochrane, Thomas A; O'Sullivan, Aisling D

    2016-04-15

    Sediment and heavy metals in stormwater runoff are key pollutants of urban waterways, and their presence in stormwater is driven by climatic factors such as rainfall intensity. This study describes the total suspended solids (TSS) and heavy metal concentrations found in runoff from four different urban surfaces within a residential/institutional catchment, in a climate where rainfall is typically of low intensity (runoff quality from a compilation of international studies. The road runoff had the highest TSS concentrations, while copper and galvanized roof runoff had the highest copper and zinc concentrations, respectively. Pollutant concentrations were found to be significantly different between surfaces; quantification and prediction of pollutant contributions from urban surfaces should thus take account of the different surface materials, instead of being aggregated into more generalized categories such as land use. The TSS and heavy metal concentrations were found to be at the low to medium end of ranges observed internationally, except for total copper and zinc concentrations generated by dissolution of copper and galvanized roofing material respectively; these concentrations were at least as high as those reported internationally. TSS wash-off from the roofs was seen to be a source-limited process, where all available TSS is washed off during the rain event despite the low intensity rainfall, whereas both road TSS and heavy metals wash-off from roof and road surfaces appeared to all be transport-limited and therefore some carryover of pollutants occurs between rain events. A first flush effect was seen from most surfaces for TSS, but not for heavy metals. This study demonstrates that in low intensity rainfall climates, quantification of untreated runoff quality from key individual surface types in a catchment are needed to enable development of targeted and appropriately sized stormwater treatment systems. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Low-intensity infrared laser effects on zymosan-induced articular inflammatory response

    Science.gov (United States)

    Januária dos Anjos, Lúcia Mara; da Fonseca, Adenilson d. S.; Gameiro, Jacy; de Paoli, Flávia

    2015-03-01

    Low-level therapy laser is a phototherapy treatment that involves the application of low power light in the red or infrared wavelengths in various diseases such as arthritis. In this work, we investigated whether low-intensity infrared laser therapy could cause death by caspase-6 apoptosis or DNA damage pathways in cartilage cells after zymosaninduced articular inflammatory process. Inflammatory process was induced in C57BL/6 mouse by intra-articular injection of zymosan into rear tibio-tarsal joints. Thirty animals were divided in five groups: (I) control, (II) laser, (III) zymosan-induced, (IV) zymosan-induced + laser and (V). Laser exposure was performed after zymosan administration with low-intensity infrared laser (830 nm), power 10 mW, fluence 3.0 J/cm2 at continuous mode emission, in five doses. Twenty-four hours after last irradiation, the animals were sacrificed and the right joints fixed and demineralized. Morphological analysis was observed by hematoxylin and eosin stain, pro-apoptotic (caspase-6) was analyzed by immunocytochemistry and DNA fragmentation was performed by TUNEL assay in articular cartilage cells. Inflammatory process was observed in connective tissue near to articular cartilage, in IV and V groups, indicating zymosan effect. This process was decreased in both groups after laser treatment and dexamethasone. Although groups III and IV presented higher caspase-6 and DNA fragmentation percentages, statistical differences were not observed when compared to groups I and II. Our results suggest that therapies based on low-intensity infrared lasers could reduce inflammatory process and could not cause death by caspase-6 apoptosis or DNA damage pathways in cartilage cells after zymosan-induced articular inflammatory process.

  10. Results of using low-intensity laser radiation for plumbum intoxication

    Science.gov (United States)

    Dejneka, S. Y.

    1999-11-01

    We have studied the noninvasive effect of low-intensive laser impulse radiation in the infrared spectrum region on the liver projection site in experimental lead intoxication achieved by means of intragastric administration of Pb acetate to albino rats over a period of 30 days in a dose of 30 mg/kg. We determined a number of indices in laboratory animals which characterized the state of the nervous system, immune system, muscular performance efficiency. We have also investigated the hematologic indices and the blood and urinary delta-aminolevulinic acid content as well as the plumbum levels in the blood, urine and the animals' inner organs.

  11. Electrostatic system of background suppression under detection of low-intensive ion beams

    International Nuclear Information System (INIS)

    Dubrovin, M.M.; Belyaev, V.A.

    2002-01-01

    Paper describes electrostatic system to suppress background at recording of low-intensive particle fluxes with transverse cross section exceeding the area of detector inlet aperture. Electrostatic system comprises 5 electrodes ensuring such spatial distribution of electrostatic field that enables accumulation of beam all ions with 30 x 40 mm 2 cross section at inlet aperture of secondary electron multiplier (SEM) with 9 mm diameter. In this case, ion trajectories prior to enter SEM are turned by 180 deg thus essentially improving signal/background ratio [ru

  12. Reception of low-intensity millimeter-wave electromagnetic radiation by the electroreceptors in skates

    International Nuclear Information System (INIS)

    Akoev, G.N.; Avelev, V.D.

    1995-01-01

    Low intensity millimeter-wave electromagnetic radiation of less than 10 mW cm -2 power intensity has a nonthermal effect on the body and it is widely used in medical practice for treatment of various diseases. Nevertheless, the effect of EMR on biological tissues is not understood. The skin and its sensory receptors are considered to be responsible for EMR reception, but this has yet to be confirmed. The present experiments were designed to study the effect of millimeter-wave electromagnetic radiation on the ampullae of Lorenzini in skates, which are very sensitive to weak electrical stimuli at low frequency. (author)

  13. Low-intensity extracorporeal shockwave therapy in the treatment of postprostatectomy erectile dysfunction

    DEFF Research Database (Denmark)

    Frey, Anders; Sønksen, Jens; Fode, Mikkel

    2016-01-01

    OBJECTIVE: The objective was to investigate the effect and feasibility of low-intensity extracorporeal shockwave therapy (LI-ESWT) as a treatment for erectile dysfunction (ED) after bilateral nerve-sparing radical prostatectomy (RP). MATERIALS AND METHODS: Patients who had undergone robot......-assisted bilateral nerve-sparing RP more than a year before entering this pilot study, had no preoperative ED and were suffering from mild to severe postoperative ED were invited to participate. Six treatments were given over a 6 week period, using the Duolith® SD1 T-Top machine. The effect of the treatment...

  14. Low intensity aerobic exercise and oxidative stress markers in older adults.

    Science.gov (United States)

    Bouzid, Mohamed A; Hammouda, Omar; Matran, Régis; Robin, Sophie; Fabre, Claudine

    2014-10-01

    This comparative study examined the effects of regular low intensity aerobic exercise on oxidative stress markers in older adults. The study was carried out on 15 sedentary subjects (age: 65.1 ± 3.5 years) versus 18 subjects performing fitness exercises (age: 65.8 ± 3.3 years). Before and after an incremental exercise test, oxidative stress markers were assessed. Superoxide dismutase was higher at rest and at the recovery for the physically active subjects compared with sedentary subjects (p aerobic exercise may be useful to prevent the decline of antioxidants linked with aging.

  15. Physical cleaning by bubbly streaming flow in an ultrasound field

    Science.gov (United States)

    Yamashita, Tatsuya; Ando, Keita

    2017-11-01

    Low-intensity ultrasonic cleaning with gas-supersaturated water is a promising method of physical cleaning without erosion; we are able to trigger cavitation bubble nucleation by weak ultrasound under gas supersaturation and thus clean material surfaces by mild bubble dynamics. Here, we perform particle image velocimetry (PIV) measurement of liquid flow and cavitation bubble translation in an ultrasonic cleaning bath driven at 28 kHz and then relate it to cleaning tests using glass slides at which silica particles are attached. The ultrasound pressure amplitude at the cleaning spot is set at 1.4 atm. We select the supersaturation level of dissolved oxygen (DO) as a parameter and control it by oxygen microbubble aeration. It follows from the PIV measurement that the liquid flow is enhanced by the cavitation bubble translation driven by acoustic radiation force; this trend becomes clearer when the bubbles appear more densely as the DO supersaturation increases. In the cleaning tests, the cleaned areas appear as straight streaks. This suggests that physical cleaning is achieved mainly by cavitation bubbles that translate in ultrasound fields.

  16. [The ultrastructure of Sertoli cells and spermatogonia in the rats exposed to radiation under conditions of therapeutic and prophylactic application of low-intensity electromagnetic emission].

    Science.gov (United States)

    Korolev, Y N; Bobrovnitskii, I P; Geniatulina, M S; Nikulina, L A; Mikhailik, L V

    2018-04-09

    it has been demonstrated in various experimental studies that radiation exposure produces a negative impact on the processes of spermatogenesis associated with the disturbances of the microcirculation processes in the testes and the development of cellular and intracellular disintegration expressed as destructive changes in the cells leading to their death. The objective of the present study was to detect the ultrastructural abnormalities in the cells of Sertoli and spermatogonia under conditions of their exposure to radiation and to identify the peculiarities of their regeneration under the influence of the therapeutic and prophylactic application of low-intensity ultra-high frequency (UHF) electromagnetic radiation (EMR) and low-intensity low-frequency magnetic field (MF). The experiments were carried out on 28 non-pedigree mature male rats with the body weight 180-220 g that were divided into four groups. The first study group was comprised of the animals exposed to radiation followed by the application of low-intensity ultra-high frequency UHF electromagnetic radiation EMR. The rats in the second study group experienced effects of radiation and low-intensity low-frequency MF. The animals of the third (control) group were exposed to radiation alone, and those comprising the fourth group 1 (only radiation exposure) were considered to be intact. The studies with the use of electron microscopy showed that the therapeutic and prophylactic application of low-intensity ultra-high frequency (UHF) electromagnetic radiation and low-intensity low-frequency magnetic field caused the decrease in the number and the severity of post-radiation defects in the treated cells together with the increase of the number and size of mitochondria as well as hyperplasia of ribosomes; moreover, it promoted cellular and intracellular regeneration. UHF electromagnetic radiation had a more pronounced stimulating effect on the regeneration processes as compared with low-frequency MF

  17. Vascular ultrasound.

    Science.gov (United States)

    Pilcher, D B; Ricci, M A

    1998-04-01

    Surgeon-interpreted diagnostic ultrasound has become the preferred screening test and often the definitive test for the diagnosis of arterial stenosis, aneurysm, and venous thrombosis. As a modality for surveillance, its noninvasive quality makes it particularly appealing as the test of choice to screen patients for abdominal aortic aneurysms or to perform follow-up examinations on those patients with a carotid endartectomy or in situ bypass grafts. The increasing reliance on intraoperative duplex imaging of vascular procedures demands that the surgeon learn the skills to perform the studies without a technologist or radiologist to interpret the examination.

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... pictures of a man’s prostate gland and to help diagnose symptoms such as difficulty urinating or an ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... There are three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams ... are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is used to evaluate the: bladder seminal vesicles prostate Transrectal ultrasound, a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ultrasound transducer into ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... questions or for a referral to a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... abnormal masses, such as tumors. In an ultrasound examination, a transducer both sends the sound waves into ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... help to distract the child and make the time pass quickly. The ultrasound exam room may have ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal imaging technique ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... in the sperm or urine following the procedure. After an ultrasound examination, you should be able to ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  5. Obstetrical Ultrasound

    Science.gov (United States)

    ... heartbeat can be seen as an ongoing ultrasound movie. Ultrasound devices also use Doppler, a special application ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... menstrual problems Ultrasound exams also help identify: palpable masses such as ovarian cysts and uterine fibroids ovarian ... In children, pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... most ultrasound exams, you will be positioned lying face-up on an examination table that can be ... region of the prostate. A biopsy will add time to the procedure. If a Doppler ultrasound study ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  13. In vitro effect of low intensity laser on the cytotoxicity produced by substances released by bleaching gel

    Directory of Open Access Journals (Sweden)

    Caroline Maria Gomes Dantas

    2010-12-01

    Full Text Available This in vitro study aimed to analyze the effect of different parameters of phototherapy with low intensity laser on the viability of human dental pulp fibroblasts under the effect of substances released by bleaching gel. Cells were seeded into 96 wells plates (1 x 10³ cells/well and placed in contact with culture medium conditioned by a 35 % hydrogen peroxide bleaching gel for 40 minutes, simulating the clinical condition of the in-office bleaching treatment. Cells cultured in ideal growth conditions served as positive control group (PC, and the cells grown in conditioned medium and non-irradiated served as negative control group (NC. Cells grown in conditioned medium were submitted to a single irradiation with a diode laser (40 mW, 0.04 cm² emitting at visible red (660 nm; RL or near infrared (780 nm; NIR using punctual technique, in contact mode and energy densities of 4, 6 or 10 J/cm². The cell viability was analyzed through the MTT reduction assay immediately and 24 hours after the irradiation. The data was compared by ANOVA followed by the Tukey's test (p < 0.05. The cell viability increased significantly in 24 hours within each group. The PC presented cell viability significantly higher than NC in both experimental times. Only the NIR/10 J/cm² group presented cell viability similar to that of PC in 24 hours. The phototherapy with low intensity laser in defined parameters is able to compensate the cytotoxic effects of substances released by 35 % hydrogen peroxide bleaching gel.

  14. Influence of constant, alternating and cyclotron low-intensity electromagnetic fields on fibroblast proliferative activity in vitro.

    Science.gov (United States)

    Afinogenov, Gennadi; Afinogenova, Anna; Kalinin, Andrey

    2009-12-16

    Available data allow assuming the presence of stimulation of reparative processes under influence of low-intensity electromagnetic field, commensurable with a magnetic field of the Earth. Research of effects of low-intensity electromagnetic fields on fibroblast proliferative activity in human lungs in cell culture was performed.The influence of a constant electromagnetic field, an alternating electromagnetic field by frequency of 50 Hz and cyclotron electromagnetic field with identical intensity for all kinds of fields - 80 mcTl - on value of cellular mass and a correlation of live and dead cells in culture is investigated in three series of experiments. We used the universal electromagnetic radiator generating all three kinds of fields and supplied by a magnetometer which allows measuring the intensity of accurate within 0.1 mcTl including taking into account the Earth's magnetic field intensity.The peak value for stimulation cellular proliferation in the present experiences was two-hour influence by any of the specified kinds of electromagnetic fields. The irradiation by cyclotron electromagnetic field conducts positive dynamics in growth of live cells (up to 206+/-22%) and decreases the number of dead cells (down to 31+/-6%). Application of cyclotron magnetic fields promoted creation of optimum conditions for proliferation. As a result of researches we observed the reliable 30% increase of nitro-tetrazolium index (in nitro-tetrazolium blue test) after irradiation by cyclotron electromagnetic field in experience that testifies to strengthening of the cell breathing of living cells.In our opinion, it is necessary to pay attention not only to a pure gain of cells, but also to reduction of number dead cells that can be criterion of creation of optimum conditions for their specific development and valuable functioning.

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Pelvic Ultrasound Imaging? Ultrasound waves are ...

  16. Effect of low-intensity electromagnetic radiation on structurization properties of bacterial lipopolysaccharide

    Directory of Open Access Journals (Sweden)

    Grigory E. Brill

    2014-09-01

    Full Text Available Purpose — to investigate the effects of low-intensity electromagnetic radiation on the process of dehydration selforganization of bacterial lipopolysaccharide (LPS. Material and Methods — The method of wedge dehydration has been used to study the structure formation of bacterial LPS. Image-phases analysis included their qualitative characteristics, as well as the calculation of quantitative indicators, followed by statistical analysis. Results — Low-intensity ultra high frequency (UHF radiation (1 GHz, 0.1 μW/cm2, 10 min has led to the changes in the suspension system of the LPS-saline reflected in the kinetics of structure formation. Conclusion — 1 GHz corresponds to the natural frequency of oscillation of water clusters and, presumably, the effect of UHF on structure of LPS mediates through the changes in water-salt environment. Under these conditions, properties of water molecules of hydration and possibly the properties of hydrophobic and hydrophilic regions in the molecule of LPS, which can affect the ability of toxin molecules to form aggregates change. Therefore the LPS structure modification may result in the change of its toxic properties.

  17. Arm and leg substrate utilization and muscle adaptation after prolonged low-intensity training

    DEFF Research Database (Denmark)

    Helge, Jørn Wulff

    2010-01-01

    This review will focus on current data where substrate metabolism in arm and leg muscle is investigated and discuss the presence of higher carbohydrate oxidation and lactate release observed during arm compared with leg exercise. Furthermore, a basis for a possible difference in substrate partiti...... at comparable workloads. Finally, the influence and capacity of low-intensity training to influence metabolic fitness in the face of a limited effect on aerobic fitness will be challenged....... partitioning between endogenous and exogenous substrate during arm and leg exercise will be debated. Moreover the review will probe if differences between arm and leg muscle are merely a result of different training status rather than a qualitative difference in limb substrate regulation. Along this line...... the review will address the available studies on low-intensity training performed separately with arm or legs or as whole-body training to evaluate if this leads to different adaptations in arm and leg muscle resulting in different substrate utilization patterns during separate arm or leg exercise...

  18. Dysmorphic choroid plexuses and hydrocephalus associated with increased nuchal translucency: early ultrasound markers of de novo thanatophoric dysplasia type II with cloverleaf skull (Kleeblattschaedel).

    Science.gov (United States)

    Tonni, Gabriele; Palmisano, Marcella; Ginocchi, Vladimiro; Ventura, Alessandro; Baldi, Maurizia; Baffico, Ave Maria

    2014-11-01

    Prenatal diagnosis of thanatophoric dysplasia (TD) type II presenting in the first trimester with increased nuchal translucency (NT) and cloverleaf skull (Kleeblattschaedel) have been scantly reported in the medical record. Abnormal choroid plexus has been seen in association with fetal anomalies. Here we described a case of increased NT associated with indented choroid plexuses, early onset hydrocephalus and cloverleaf skull in a fetus subsequently diagnosed at early second trimester to carry a de novo mutation encoding for TD type II. The findings of dysmorphic choroid plexus, early onset hydrocephalus and cloverleaf skull at first trimester scan may be early, useful ultrasound markers of TD type II. Molecular analysis to control for possible overlapping syndromes were performed and resulted negative. Postmortem X-ray and 3D-CT scan confirmed the cloverleaf skull, narrow thorax, straight femur with rhizomelic shortening of the limbs and the presence of a communicating hydrocephalus. © 2014 Japanese Teratology Society.

  19. The distinguishing effects of low-intensity electromagnetic radiation of different extremely high frequencies on Enterococcus hirae: growth rate inhibition and scanning electron microscopy analysis.

    Science.gov (United States)

    Hovnanyan, K; Kalantaryan, V; Trchounian, A

    2017-09-01

    A low-intensity electromagnetic field of extremely high frequency has inhibitory and stimulatory effects on bacteria, including Enterococcus hirae. It was shown that the low-intensity (the incident power density of 0·06 mW cm -2 ) electromagnetic field at the frequencies of 51·8 GHz and 53 GHz inhibited E. hirae ATCC 9790 bacterial growth rate; a stronger effect was observed with 53 GHz, regardless of exposure duration (0·5 h, 1 h or 2 h). Scanning electron microscopy analysis of these effects has been done; the cells were of spherical shape. Electromagnetic field at 53 GHz, but not 51·8 GHz, changed the cell size-the diameter was enlarged 1·3 fold at 53 GHz. These results suggest the difference in mechanisms of action on bacteria for electromagnetic fields at 51·8 GHz and 53 GHz. A stronger inhibitory effect of low-intensity electromagnetic field on Enterococcus hirae ATCC 9790 bacterial growth rate was observed with 53 GHz vs 51·8 GHz, regardless of exposure duration. Scanning electron microscopy analysis showed that almost all irradiated cells in the population have spherical shapes similar to nonirradiated ones, but they have increased diameters in case of irradiated cells at 53 GHz, but not 51·8 GHz. The results are novel, showing distinguishing effects of low-intensity electromagnetic field of different frequencies. They could be applied in treatment of food and different products in medicine and veterinary, where E. hirae plays an important role. © 2017 The Society for Applied Microbiology.

  20. Competences required for the delivery of high and low-intensity cognitive behavioural interventions for chronic fatigue, chronic fatigue syndrome/ME and irritable bowel syndrome.

    Science.gov (United States)

    Rimes, Katharine A; Wingrove, Janet; Moss-Morris, Rona; Chalder, Trudie

    2014-11-01

    Cognitive behavioural interventions are effective in the treatment of chronic fatigue, chronic fatigue syndrome (sometimes known as ME or CFS/ME) and irritable bowel syndrome (IBS). Such interventions are increasingly being provided not only in specialist settings but in primary care settings such as Improving Access to Psychological Therapies (IAPT) services. There are no existing competences for the delivery of "low-intensity" or "high-intensity" cognitive behavioural interventions for these conditions. To develop "high-intensity" and "low-intensity" competences for cognitive behavioural interventions for chronic fatigue, CFS/ME and IBS. The initial draft drew on a variety of sources including treatment manuals and other information from randomized controlled trials. Therapists with experience in providing cognitive behavioural interventions for CF, CFS/ME and IBS in research and clinical settings were consulted on the initial draft competences and their suggestions for minor amendments were incorporated into the final versions. Feedback from experienced therapists was positive. Therapists providing low intensity interventions reported that the competences were also helpful in highlighting training needs. These sets of competences should facilitate the training and supervision of therapists providing cognitive behavioural interventions for chronic fatigue, CFS/ME and IBS. The competences are available online (see table of contents for this issue: http://journals.cambridge.org/jid_BCP) or on request from the first author.

  1. Low-intensity laser irradiation use for oral and lip precancer treatment

    Science.gov (United States)

    Kunin, Anatoly A.; Podolskaya, Elana E.; Stepanov, Nicolay N.; Petrov, Anatoly; Erina, Stanislava V.; Pankova, Svetlana N.

    1996-09-01

    Precancer and background diseases of the oral mucosa and lips, such as lichen planus, chronic ulcers and fissures, meteorological heilit, lupus erythematosus, after radiation heilit were treated by low-intensity laser irradiation. Laser therapy of the over-mentioned diseases was combined with medicinal treatment. All the patients were selected and treated in the limits of dispensary system. THe choice of diagnostic methods were made according to each concrete nosological form. A great attention was paid to the goal- directly sanitation of the oral cavity and treatment of attended internal diseases. The etiological factors were revealed and statistically analyzed. The results received during our researches demonstrated high effectiveness of laser irradiation combined with medicinal therapy in the treatment of oral mucosa and lips precancer diseases.

  2. Tritium breeding experiments in a fusion blanket assembly using a low-intensity neutron generator

    International Nuclear Information System (INIS)

    Dalton, A.W.; Woodley, H.J.; McGregor, B.J.

    1987-01-01

    Experiments have been carried out to determine the accuracy with which tritium production rates (TPRs) can be measured in a fusion blanket assembly of non-spherical geometry by a non-central low intensity D-T neutron source (2x10 10 neutrons per second). The tritium production was determined for samples of lithium carbonate containing high enrichments of 6 Li(96%) and 7 Li(99.9%). The measured data were used to check the accuracy with which the TPRs could be numerically predicted using current nuclear data and calculational methods. The numerical predictions from tritium production from the 7 Li samples agreed within the experimental errors of the measurements, but 6 Li measurements which differ by more than 20 per cent from the predicted values were observed in the lower half of the assembly

  3. Muscle injury after low-intensity downhill running reduces running economy.

    Science.gov (United States)

    Baumann, Cory W; Green, Michael S; Doyle, J Andrew; Rupp, Jeffrey C; Ingalls, Christopher P; Corona, Benjamin T

    2014-05-01

    Contraction-induced muscle injury may reduce running economy (RE) by altering motor unit recruitment, lowering contraction economy, and disturbing running mechanics, any of which may have a deleterious effect on endurance performance. The purpose of this study was to determine if RE is reduced 2 days after performing injurious, low-intensity exercise in 11 healthy active men (27.5 ± 5.7 years; 50.05 ± 1.67 VO2peak). Running economy was determined at treadmill speeds eliciting 65 and 75% of the individual's peak rate of oxygen uptake (VO2peak) 1 day before and 2 days after injury induction. Lower extremity muscle injury was induced with a 30-minute downhill treadmill run (6 × 5 minutes runs, 2 minutes rest, -12% grade, and 12.9 km·h(-1)) that elicited 55% VO2peak. Maximal quadriceps isometric torque was reduced immediately and 2 days after the downhill run by 18 and 10%, and a moderate degree of muscle soreness was present. Two days after the injury, steady-state VO2 and metabolic work (VO2 L·km(-1)) were significantly greater (4-6%) during the 65% VO2peak run. Additionally, postinjury VCO2, VE and rating of perceived exertion were greater at 65% but not at 75% VO2peak, whereas whole blood-lactate concentrations did not change pre-injury to postinjury at either intensity. In conclusion, low-intensity downhill running reduces RE at 65% but not 75% VO2peak. The results of this study and other studies indicate the magnitude to which RE is altered after downhill running is dependent on the severity of the injury and intensity of the RE test.

  4. Low Intensity laser therapy in patients with burning mouth syndrome: a randomized, placebo-controlled study

    Directory of Open Access Journals (Sweden)

    Norberto Nobuo SUGAYA

    Full Text Available Abstract The aim of this study was to assess the effectiveness of low intensity laser therapy in patients with Burning Mouth Syndrome (BMS. Thirty BMS subjects were randomized into two groups – Laser (LG and Placebo (CG. Seven patients dropped out, leaving 13 patients in LG and 10 patients in CG. Each patient received 4 irradiations (laser or placebo twice a week, for two consecutive weeks (blinded to the type of irradiation received. Infrared laser (AsGaAI irradiations were applied to the affected mucosa in scanning mode, wavelength of 790 nm, output power of 20 mW and fluence of 6 J/cm2. A visual analogue scale (VAS was used to assess the therapeutic effect before and after each irradiation, and at all the control time periods: 7, 14, 30, 60 and 90 days after the last irradiation. One researcher delivered irradiation and another recorded the results. Both researchers were blinded, the first to the results, and the second to the type of radiation applied. The results were categorized according to the percentage of symptom level variation, and showed a statistically better response in LG in only two categories of the control checkpoints (p=0.02; Fisher’s Exact Test. According to the protocol used in this study, low intensity laser therapy is as beneficial to patients with BMS as placebo treatment, indicating a great emotional component of involvement in BMS symptomatology. Nevertheless, there were positive results in some statistical analyses, thus encouraging further research in BMS laser therapy with other irradiation parameters.

  5. SELECTIVE ACTIVATION OF THE RECTUS ABDOMINIS MUSCLE DURING LOW-INTENSITY AND FATIGUING TASKS

    Directory of Open Access Journals (Sweden)

    Paulo H. Marchetti

    2011-06-01

    Full Text Available In order to understand the potential selective activation of the rectus abdominis muscle, we conducted two experiments. In the first, subjects performed two controlled isometric exercises: the curl up (supine trunk raise and the leg raise (supine bent leg raise at low intensity (in which only a few motor units are recruited. In the second experiment, subjects performed the same exercises, but they were required to maintain a certain force level in order to induce fatigue. We recorded the electromyographic (EMG activities of the lower and upper portions of the rectus abdominis muscle during the exercises and used spatial-temporal and frequency analyses to describe muscle activation patterns. At low-intensity contractions, the ratio between the EMG intensities of the upper and lower portions during the curl up exercise was significantly larger than during the leg raise exercise (p = 0.02. A cross-correlation analysis indicated that the signals of the abdominal portions were related to each other and this relation did not differ between the tasks (p = 0.12. In the fatiguing condition, fatigue for the upper portion was higher than for the lower portion during the curl up exercise (p = 0.008. We conclude that different exercises evoked, to a certain degree, individualized activation of each part of the rectus abdominis muscle, but different portions of the rectus abdominis muscle contributed to the same task, acting like a functional unit. These results corroborate the relevance of varying exercise to modify activation patterns of the rectus abdominis muscle

  6. Low Intensity Physical Exercise Attenuates Cardiac Remodeling and Myocardial Oxidative Stress and Dysfunction in Diabetic Rats

    Directory of Open Access Journals (Sweden)

    C. Gimenes

    2015-01-01

    Full Text Available We evaluated the effects of a low intensity aerobic exercise protocol on cardiac remodeling and myocardial function in diabetic rats. Wistar rats were assigned into four groups: sedentary control (C-Sed, exercised control (C-Ex, sedentary diabetes (DM-Sed, and exercised diabetes (DM-Ex. Diabetes was induced by intraperitoneal injection of streptozotocin. Rats exercised for 9 weeks in treadmill at 11 m/min, 18 min/day. Myocardial function was evaluated in left ventricular (LV papillary muscles and oxidative stress in LV tissue. Statistical analysis was given by ANOVA or Kruskal-Wallis. Echocardiogram showed diabetic groups with higher LV diastolic diameter-to-body weight ratio and lower posterior wall shortening velocity than controls. Left atrium diameter was lower in DM-Ex than DM-Sed (C-Sed: 5.73±0.49; C-Ex: 5.67±0.53; DM-Sed: 6.41±0.54; DM-Ex: 5.81±0.50 mm; P<0.05 DM-Sed vs C-Sed and DM-Ex. Papillary muscle function was depressed in DM-Sed compared to C-Sed. Exercise attenuated this change in DM-Ex. Lipid hydroperoxide concentration was higher in DM-Sed than C-Sed and DM-Ex. Catalase and superoxide dismutase activities were lower in diabetics than controls and higher in DM-Ex than DM-Sed. Glutathione peroxidase activity was lower in DM-Sed than C-Sed and DM-Ex. Conclusion. Low intensity exercise attenuates left atrium dilation and myocardial oxidative stress and dysfunction in type 1 diabetic rats.

  7. The hypoalgesic effects of low-intensity infrared laser therapy: a study on 555 cases

    Science.gov (United States)

    Tam, Giuseppe

    2004-09-01

    Objective: Low energy lasers are widely used to treat a variety of musculoskeletal conditions. The aim of this clinical study is to determine the action of the IR diode laser 904 nm pulsed on pain reduction therapy. Summary Background Data: With respect to pain, has been shown the Low power density laser increases the endorphin synthesis in the dorsal posterior horn of the spinal cord stopping the production of bradykinin and serotonin. Besides laser causes local vasodilatation of the capillaries and an improved circulation of drainage liquids in interstitial space causing an analgesic effect. Additionally, laser interferes in the cytochines (TNF-α, interleukin-1 and interleukin-6) that drive inflammation in the arthritis and are secreted from CD4 e T cells. Methods: Treatment was carried out on 555 cases and 525 patients (322 women and 203 men) in the period between 1987 and 2002. The patients, whose age ranged from 25 to 70, with a mean age of 45 years, were suffering from rheumatic, degenerative and traumatic pathologies. The majority of the patients had been seen by orthopaedists and rheumatologists and had undergone x-ray, ultrasound scanning, Tac, RM examination. All patients had received drug-based treatment and/or physiotherapy with poor results. Two thirds were experiencing acute symptomatic pain, while the others presented a chronic pathology with recurrent crises. We used a pulsed IR diode laser, GaAs 904 nm, maximum power 60 W, frequency impulse 1300 Hz, pulsed duration 200 nanoseconds; peak power per pulse 27W; maximal energy density: 9J/cm2; total number of Joules per treatment session: 10-75J/cm2, chronic 12-90J/cm2. Average number of applications: 12; maximum number of applications: 20. Results: In the evaluation of the results the following parameters have been considered: disappearance of spontaneous and induced pain (Likert scale, Rolland Morris disability scale, dynamometer). The pathologies treated were osteoarthritis in general, epicondylitis

  8. [The action of low-intensity extremely high-freguency electromagnetic radiation on growth parameters for bacteria Enterococcus hirae].

    Science.gov (United States)

    Oganian, V; Sarkisian, A; Tadevosian, A; Torchunian, A

    2008-01-01

    It has been found that the exposure of Enterococcus hirae ATCC9790, grown under anaerobic conditions for 30 min or 1 h, to low-intensity (flux capacity 0.06 mW/sm2) coherent electromagnetic radiation (EMI) of extremely high-frequency 45 - 53 GHz), or millimeter waves causes a marked prolongation of the lag-growth phase and a decrease in their specific growth rate, the inhibitory effect increasing in the frequency range from 49 to 53 GHz. The effect enhanced as duration of expocure was encreased from 30 min to 1 h; however, further increase in exposure duration to 2 h did not cause an enhancement of the effect. It has been shown that the action of extremely high-frequency EMI on these bacteria does not depend on medium pH (pH 8.0 or pH 6.0). It is proposed that these bacteria have defensive or reparation mechanisms which compensate for the action of radiation; the occurrence of different mechanisms for pH regulation is not ruled out.

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  10. Ultrasound to stimulate mandibular bone defect healing : A placebo-controlled single-blind study in rats

    NARCIS (Netherlands)

    Schortinghuis, J; Ruben, JL; Raghoebar, GM; Stegenga, B

    Purpose: Because of the limitations of the body to heal large maxillofacial bone defects, an attempt was made to stimulate mandibular defect healing with low intensity pulsed ultrasound in rats. This ultrasound consists of a 1.5-MHz pressure wave administered in pulses of 200 musec, with an average

  11. Low-intensity Extracorporeal Shock Wave Treatment Improves Erectile Function: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Lu, Zhihua; Lin, Guiting; Reed-Maldonado, Amanda; Wang, Chunxi; Lee, Yung-Chin; Lue, Tom F

    2017-02-01

    As a novel therapeutic method for erectile dysfunction (ED), low-intensity extracorporeal shock wave treatment (LI-ESWT) has been applied recently in the clinical setting. We feel that a summary of the current literature and a systematic review to evaluate the therapeutic efficacy of LI-ESWT for ED would be helpful for physicians who are interested in using this modality to treat patients with ED. A systematic review of the evidence regarding LI-ESWT for patients with ED was undertaken with a meta-analysis to identify the efficacy of the treatment modality. A comprehensive search of the PubMed and Embase databases to November 2015 was performed. Studies reporting on patients with ED treated with LI-ESWT were included. The International Index of Erectile Function (IIEF) and the Erection Hardness Score (EHS) were the most commonly used tools to evaluate the therapeutic efficacy of LI-ESWT. There were 14 studies including 833 patients from 2005 to 2015. Seven studies were randomized controlled trials (RCTs); however, in these studies, the setup parameters of LI-ESWT and the protocols of treatment were variable. The meta-analysis revealed that LI-ESWT could significantly improve IIEF (mean difference: 2.00; 95% confidence interval [CI], 0.99-3.00; pwaves per treatment, and duration of LI-ESWT treatment were closely related to clinical outcome, especially regarding IIEF improvement. The number of studies of LI-ESWT for ED have increased dramatically in recent years. Most of these studies presented encouraging results, regardless of variation in LI-ESWT setup parameters or treatment protocols. These studies suggest that LI-ESWT could significantly improve the IIEF and EHS of ED patients. The publication of robust evidence from additional RCTs and longer-term follow-up would provide more confidence regarding use of LI-ESWT for ED patients. We reviewed 14 studies of men who received low-intensity extracorporeal shock wave treatment (LI-ESWT) for erectile dysfunction (ED

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce ... the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and ...

  14. The impact of high and low-intensity exercise in adolescents with movement impairment.

    Directory of Open Access Journals (Sweden)

    Francesca Liu

    Full Text Available Five to six percent of young people have movement impairment (MI associated with reduced exercise tolerance and physical activity levels which persist into adulthood. To better understand the exercise experience in MI, we determined the physiological and perceptual responses during and following a bout of exercise performed at different intensities typically experienced during sport in youth with MI. Thirty-eight adolescents (11-18 years categorised on the Bruininks-Oseretsky Test of Motor Proficiency-2 Short-Form performed a peak oxygen uptake bike test ([Formula: see text] test at visit 1 (V1. At visits 2 (V2 and 3 (V3, participants were randomly assigned to both low-intensity (LI 30min exercise at 50% peak power output (PPO50% and high-intensity (HI 30s cycling at PPO100%, interspersed with 30s rest, for 30min protocol (matched for total work. Heart rate (HR and rating of perceived exertion (RPE for legs, breathing and overall was measured before, during and at 1, 3 and 7-min post-exercise (P1, P3, P7. There was a significant difference in [Formula: see text] between groups (MI:31.5±9.2 vs. NMI:40.0±9.5ml⋅kg-1⋅min-1, p0.05. Both groups experienced similar RPE for breathing and overall (MI:7.0±3.0 vs. NMI:6.0±2.0, p>0.05 at both intensities, but reported higher legs RPE towards the end (p<0.01. Significant differences were found in HRrecovery at P1 post-HI (MI:128±25.9 vs. NMI:154±20.2, p<0.05 but not for legs RPE. Perceived fatigue appears to limit exercise in youth with MI in both high and low-intensity exercise types. Our findings suggest interventions reducing perceived fatigue during exercise may improve exercise tolerance and positively impact on engagement in physical activities.

  15. Leafcutter Ant Nests Inhibit Low-Intensity Fire Spread in the Understory of Transitional Forests at the Amazon's Forest-Savanna Boundary

    Directory of Open Access Journals (Sweden)

    Karine S. Carvalho

    2012-01-01

    Full Text Available Leaf-cutter ants (Atta spp. remove leaf litter and woody debris—potential fuels—in and around their nests and foraging trails. We conducted single and three annual experimental fires to determine the effects of this leaf-cutter ant activity on the behavior of low-intensity, slow-moving fires. In a transitional forest, where the southern Amazon forest meets the Brazilian savanna, we tested whether leaf-cutter ant nests and trails (i inhibit fire spread due to a lack of fuels, and (ii, thereby, reduce the total burned area during these experimental low-intensity fires, particularly at forest edges where leaf-cutter ant abundance was higher. Fine-medium fuel mass increased with an increase in distance from ant nest, and the mean area of bare soil was greater on nests than on the forest floor. Between 60 to 90 percent of the unburned area was within 30 m of ant nests, and burned area significantly increased with increasing distance to ant nests. In addition, the number of ant nests declined with increasing distance from the forest edge, and, with exception of the first experimental fire, burned area also increased with increasing distance from the edge. The present study provides new insight to fire ecology in Amazon environments.

  16. Alterations in Aspergillus brasiliensis (niger) ATCC 9642 membranes associated to metabolism modifications during application of low-intensity electric current.

    Science.gov (United States)

    Velasco-Alvarez, Nancy; Gutiérrez-Rojas, Mariano; González, Ignacio

    2017-12-01

    The effects of electric current on membranes associated with metabolism modifications in Aspergillus brasiliensis (niger) ATCC 9642 were studied. A 450-mL electrochemical cell with titanium ruthenium-oxide coated electrodes and packed with 15g of perlite, as inert support, was inoculated with A. brasiliensis spores and incubated in a solid inert-substrate culture (12 d; 30°C). Then, 4.5days after starting the culture, a current of 0.42mAcm -2 was applied for 24h. The application of low-intensity electric current increased the molecular oxygen consumption rate in the mitochondrial respiratory chain, resulting in high concentrations of reactive oxygen species, promoting high lipoperoxidation levels, according to measured malondialdehyde, and consequent alterations in membrane permeability explained the high n-hexadecane (HXD) degradation rates observed here (4.7-fold higher than cultures without current). Finally, cell differentiation and spore production were strongly stimulated. The study contributes to the understanding of the effect of current on the cell membrane and its association with HXD metabolism. Copyright © 2017. Published by Elsevier B.V.

  17. Effects of lightweight outdoor clothing on the prevention of hypothermia during low-intensity exercise in the cold.

    Science.gov (United States)

    Burtscher, Martin; Kofler, Philipp; Gatterer, Hannes; Faulhaber, Martin; Philippe, Marc; Fischer, Kathrin; Walther, Rebekka; Herten, Anne

    2012-11-01

    To study protective effects of windbreaker jacket and pants during exercise in the cold. Randomized pilot study. Climate chamber. Nine well-trained (V[Combining Dot Above]O2max 61.7 ± 6.6 mL/min/kg) sport students (6 male and 3 female participants). Subjects started walking for 1 hour in a climate chamber (0°C ambient temperature and wind speed of 10 km/h) at 70% V[Combining Dot Above]O2max wearing gloves, a T-shirt, and shorts. Then, the walking speed was reduced to 30% V[Combining Dot Above]O2max for an additional 60 minutes or until core temperature dropped below 35.5°C. Subsequently, 3 groups of 3 participants continued walking without change of clothing or obtaining additionally a cap and a windbreaker jacket or windbreaker jacket and pants. Core and skin temperature, thermal comfort. The main findings of this study were that exercising at 70% V[Combining Dot Above]O2max in the cold was sufficient to prevent hypothermia and that during low-intensity exercise (30% V[Combining Dot Above]O2max), the combined use of a polyester cap, lightweight windbreaker jacket, and pants was necessary to increase a prehypothermic core temperature. We strongly recommend taking a cap, windbreaker jacket, and pants for the prevention of hypothermia during exhaustive walking or running in cold weather conditions.

  18. Low-intensity laser irradiation at 660 nm stimulates transcription of genes involved in the electron transport chain.

    Science.gov (United States)

    Masha, Roland T; Houreld, Nicolette N; Abrahamse, Heidi

    2013-02-01

    Low-intensity laser irradiation (LILI) has been shown to stimulate cellular functions leading to increased adenosine triphosphate (ATP) synthesis. This study was undertaken to evaluate the effect of LILI on genes involved in the mitochondrial electron transport chain (ETC, complexes I-IV) and oxidative phosphorylation (ATP synthase). Four human skin fibroblast cell models were used in this study: normal non-irradiated cells were used as controls while wounded, diabetic wounded, and ischemic cells were irradiated. Cells were irradiated with a 660 nm diode laser with a fluence of 5 J/cm(2) and gene expression determined by quantitative real-time reverse transcription (RT) polymerase chain reaction (PCR). LILI upregulated cytochrome c oxidase subunit VIb polypeptide 2 (COX6B2), cytochrome c oxidase subunit VIc (COX6C), and pyrophosphatase (inorganic) 1 (PPA1) in diabetic wounded cells; COX6C, ATP synthase, H+transporting, mitochondrial Fo complex, subunit B1 (ATP5F1), nicotinamide adenine dinucleotide (NADH) dehydrogenase (ubiquinone) 1 alpha subcomplex, 11 (NDUFA11), and NADH dehydrogenase (ubiquinone) Fe-S protein 7 (NDUFS7) in wounded cells; and ATPase, H+/K+ exchanging, beta polypeptide (ATP4B), and ATP synthase, H+ transporting, mitochondrial Fo complex, subunit C2 (subunit 9) (ATP5G2) in ischemic cells. LILI at 660 nm stimulates the upregulation of genes coding for subunits of enzymes involved in complexes I and IV and ATP synthase.

  19. Neutron beam design for low intensity neutron and gamma-ray radioscopy using small neutron sources

    CERN Document Server

    Matsumoto, T

    2003-01-01

    Two small neutron sources of sup 2 sup 5 sup 2 Cf and sup 2 sup 4 sup 1 Am-Be radioisotopes were used for design of neutron beams applicable to low intensity neutron and gamma ray radioscopy (LINGR). In the design, Monte Carlo code (MCNP) was employed to generate neutron and gamma ray beams suited to LINGR. With a view to variable neutron spectrum and neutron intensity, various arrangements were first examined, and neutron-filter, gamma-ray shield and beam collimator were verified. Monte Carlo calculations indicated that with a suitable filter-shield-collimator arrangement, thermal neutron beam of 3,900 ncm sup - sup 2 s sup - sup 1 with neutron/gamma ratio of 7x10 sup 7 , and 25 ncm sup - sup 2 s sup - sup 1 with very large neutron/gamma ratio, respectively, could be produced by using sup 2 sup 5 sup 2 Cf(122 mu g) and a sup 2 sup 4 sup 1 Am-Be(37GBq)radioisotopes at the irradiation port of 35 cm from the neutron sources.

  20. Non-perturbative measurement of low-intensity charged particle beams

    Science.gov (United States)

    Fernandes, M.; Geithner, R.; Golm, J.; Neubert, R.; Schwickert, M.; Stöhlker, T.; Tan, J.; Welsch, C. P.

    2017-01-01

    Non-perturbative measurements of low-intensity charged particle beams are particularly challenging to beam diagnostics due to the low amplitude of the induced electromagnetic fields. In the low-energy antiproton decelerator (AD) and the future extra low energy antiproton rings at CERN, an absolute measurement of the beam intensity is essential to monitor the operation efficiency. Superconducting quantum interference device (SQUID) based cryogenic current comparators (CCC) have been used for measuring slow charged beams in the nA range, showing a very good current resolution. But these were unable to measure fast bunched beams, due to the slew-rate limitation of SQUID devices and presented a strong susceptibility to external perturbations. Here, we present a CCC system developed for the AD machine, which was optimised in terms of its current resolution, system stability, ability to cope with short bunched beams, and immunity to mechanical vibrations. This paper presents the monitor design and the first results from measurements with a low energy antiproton beam obtained in the AD in 2015. These are the first CCC beam current measurements ever performed in a synchrotron machine with both coasting and short bunched beams. It is shown that the system is able to stably measure the AD beam throughout the entire cycle, with a current resolution of 30 {nA}.

  1. Design of a compact Faraday cup for low energy, low intensity ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Cantero, E.D., E-mail: esteban.cantero@cern.ch [CERN, 1211 Geneva 23 (Switzerland); Sosa, A. [CERN, 1211 Geneva 23 (Switzerland); The University of Liverpool, Liverpool (United Kingdom); Andreazza, W.; Bravin, E.; Lanaia, D.; Voulot, D. [CERN, 1211 Geneva 23 (Switzerland); Welsch, C.P. [The University of Liverpool, Liverpool (United Kingdom); The Cockcroft Institute, Sci-Tech Daresbury, Daresbury, Warrington (United Kingdom)

    2016-01-21

    Beam intensity is one of the key parameters in particle accelerators, in particular during machine commissioning, but also during operation for experiments. At low beam energies and low intensities a number of challenges arise in its measurement as commonly used non-invasive devices are no longer sensitive enough. It then becomes necessary to stop the beam in order to measure its absolute intensity. A very compact Faraday cup for determining ion beam currents from a few nanoamperes down to picoamperes for the HIE-ISOLDE post-accelerator at CERN has been designed, built and tested with beam. It has a large aperture diameter of 30 mm and a total length of only 16 mm, making it one of the most compact designs ever used. In this paper we present the different steps that were involved in the design and optimization of this device, including beam tests with two early prototypes and the final monitor. We also present an analysis of the losses caused by secondary particle emission for different repelling electrode voltages and beam energies. Finally, we show that results obtained from an analytical model for electron loss probability combined with Monte Carlo simulations of particles trajectories provide a very good agreement with experimental data.

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  3. Prostate Ultrasound

    Science.gov (United States)

    ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to ...

  5. Interventional ultrasound

    International Nuclear Information System (INIS)

    VanSonnenberg, E.

    1987-01-01

    This book contains 12 chapters and several case studies. Some of the chapter titles are: The Interplay of Ultrasound and Computed Tomography in the Planning and Execution of Interventional Procedures: Ulltrasound Guided Biopsy; Interventioal Genitourinary Sonography; Diagnosis and Treatment of Pericardial Effusion Using Ultrasonic Guidance; and New Ultrasound-Guided Interventional Procedures--Cholecystostomy, Pancreatography, Gastrostomy

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of ...

  8. Ultrasound stethoscopy

    NARCIS (Netherlands)

    E.C. Vourvouri (Eleni)

    2002-01-01

    textabstractIn this thesis we repmi the many evaluation studies with the hand-held ultrasound device in the assessment of different cardiac pathologies and in different clinical settings. The reason for using the tetm "ultrasound stethoscopy" is that these devices are augmenting our

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not use any ionizing radiation. Ultrasound scanning gives a clear picture of soft tissues that do not show up well on ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  12. Comparison of high- versus low-intensity community health worker intervention to promote newborn and child health in Northern Nigeria

    Directory of Open Access Journals (Sweden)

    Findley SE

    2013-10-01

    the five prior years (baseline: n = 6,906; follow-up: n = 2,310. The follow-up respondents were grouped by level of intensity of the CHW interventions in their community, with “low” including group activities led only by a trained community volunteer and “high” including the community volunteer activities plus CBSD from a CHW providing one-on-one advice and assistance. t-tests were used to test for significant differences from baseline to follow-up, and F-statistics, which adjust for the stratified cluster design, were used to test for significant differences between the control, low-intensity, and high-intensity intervention groups at follow-up. These analyses focused on changes in newborn and sick child care practices.Results: Anti-tetanus vaccination coverage during pregnancy increased from 69.2% at baseline to 85.7% at follow-up in the intervention areas. Breastfeeding within 24 hours increased from 42.9% to 59.0% in the intervention areas, and more newborns were checked by health workers within 48 hours (from 16.8% at baseline to 26.8% at follow-up in the intervention areas. Newborns were more likely to be checked by trained health personnel, and they received more comprehensive newborn care. Compared to the control communities, more than twice as many women in intervention communities knew to watch for specific newborn danger signs. Compared to the control and low-intensity intervention communities, more mothers in the high-intensity communities learned about the care of sick children from CHWs, with a corresponding decline those seeking advice from family or friends or traditional birth attendants. Significantly fewer mothers did nothing when their child was sick. High-intensity intervention communities experienced the most decline. Those who did nothing for children with fever or cough declined from 35% to 30%, and with diarrhea from 40% to 31%. Use of medications, both traditional and modern, increased from baseline to follow-up, with no

  13. Early High-Intensity Versus Low-Intensity Rehabilitation After Total Knee Arthroplasty (TKA) by Bade et al

    DEFF Research Database (Denmark)

    Mechlenburg, Inger; Skoffer, Birgit; Dalgas, Ulrik

    2017-01-01

    Recently, a paper entitled "Early High-Intensity Versus Low-Intensity Rehabilitation After Total Knee Arthroplasty: A Randomized Controlled Trial" was published in Arthritis Care Res by Bade et al. (1). We have read the paper with great interest and noted that the study shows essentially no diffe......Recently, a paper entitled "Early High-Intensity Versus Low-Intensity Rehabilitation After Total Knee Arthroplasty: A Randomized Controlled Trial" was published in Arthritis Care Res by Bade et al. (1). We have read the paper with great interest and noted that the study shows essentially...

  14. Increasing the field-of-view of row–column-addressed ultrasound transducers: implementation of a diverging compound lens

    DEFF Research Database (Denmark)

    Engholm, Mathias; Beers, Christopher; Bouzari, Hamed

    2018-01-01

    was fabricated of a Bi2O3 loaded RTV615 and an unloaded Hapflex 541. The lens was tested using a RCA probe, and a FOV of 32.2° was measured from water tank tests, while the FEM model yielded 33.4°. A wire phantom with 0.15 mm diameter wires was imaged at 3 MHz down to a depth of 14 cm using a synthetic aperture...... imaging sequence with single element transmissions. The beamformed image showed that wires outside the array footprint were visible, demonstrating the increased FOV....

  15. Does the Addition of M-Mode to B-Mode Ultrasound Increase the Accuracy of Identification of Lung Sliding in Traumatic Pneumothoraces?

    Science.gov (United States)

    Avila, Jacob; Smith, Ben; Mead, Therese; Jurma, Duane; Dawson, Matthew; Mallin, Michael; Dugan, Adam

    2018-04-24

    It is unknown whether the addition of M-mode to B-mode ultrasound (US) has any effect on the overall accuracy of interpretation of lung sliding in the evaluation of a pneumothorax by emergency physicians. This study aimed to determine what effect, if any, this addition has on US interpretation by emergency physicians of varying training levels. One hundred forty emergency physicians were randomized via online software to receive a quiz with B-mode clips alone or B-mode with corresponding M-mode images and asked to identify the presence or absence of lung sliding. The sensitivity, specificity, and accuracy of the diagnosis of lung sliding with and without M-mode US were compared. Overall, the sensitivities, specificities, and accuracies of B-mode + M-mode US versus B-mode US alone were 93.1% and 93.2% (P = .8), 96.0% and 89.8% (P < .0001), and 91.5% and 94.5% (P = .0091), respectively. A subgroup analysis showed that in those providers with fewer than 250 total US scans done previously, M-mode US increased accuracy from 88.2% (95% confidence interval, 86.2%-90.2%) to 94.4% (92.8%-96.0%; P = .001) and increased the specificity from 87.0% (84.5%-89.5%) to 97.2% (95.4%-99.0%; P < .0001) compared with B-mode US alone. There was no statistically significant difference observed in the sensitivity, specificity, and accuracy of B-mode + M-mode US compared with B-mode US alone in those with more than 250 scans. The addition of M-mode images to B-mode clips aids in the accurate diagnosis of lung sliding by emergency physicians. The subgroup analysis showed that the benefit of M-mode US disappears after emergency physicians have performed more than 250 US examinations. © 2018 by the American Institute of Ultrasound in Medicine.

  16. Low-intensity laser radiation in complex treatment of inflammatory diseases of parodontium

    Science.gov (United States)

    Sokolova, Irina A.; Erina, Stanislava V.

    1995-04-01

    The problem of complex treatment of inflammatory disease of parodontium has become very acute and actual at the moment. The diseases of inflammatory nature are considered to be the most vital issues of the day. The state of the local immune system of oral cavity plays the most important role in the complicated mechanism of inflammatory process development in the tissues of parodontium. Recently physical factors have become predominant in the system of complex therapy of parodontitis. The application of low-intense laser radiation (LLR) is considered to be the most important and up-to-date method in the preventive dentistry. There were 60 patients of average damage rate suffering from chronic generalizing parodontitis at the age of 25 up to 55 under observation. The major goal of examination was to get the objective results of the following methods' application: parodontium index (Russel, 1956), hygiene index (Fyodorov, Volodkina, 1971), Bacterioscopy of dental-gingival pockets content, simple and broadened stomatoscopy (Kunin, 1970), SIgA level determination in mixed saliva (Manchini et all, 1965) and R-protein level in gingival blood (Kulberg, 1990). All the patients were split into 2 groups. The first group (30 patients) has undergone the laser therapy course while the second group of 30 patients couldn't get it (LLR). Despite the kind of therapy they have undergone, all the patients have got the local anti-inflammatory medicamental therapy. The results of clinical observations have proved the fact that laser therapy application makes it possible to shorten the course of treatment in 1.5 times. The shifts of oral cavity local resistance take place in case of chronic generalizing parodontitis. The direct immunostimulating effect could be observed as a result of LLR- therapy application. The close connection of both anti-inflammatory medicamental and LLR-therapy has proved the possibility of purposeful local immune status correction in case of parodontitis.

  17. Low-Intensity Agricultural Landscapes in Transylvania Support High Butterfly Diversity: Implications for Conservation

    Science.gov (United States)

    Loos, Jacqueline; Dorresteijn, Ine; Hanspach, Jan; Fust, Pascal; Rakosy, László; Fischer, Joern

    2014-01-01

    European farmland biodiversity is declining due to land use changes towards agricultural intensification or abandonment. Some Eastern European farming systems have sustained traditional forms of use, resulting in high levels of biodiversity. However, global markets and international policies now imply rapid and major changes to these systems. To effectively protect farmland biodiversity, understanding landscape features which underpin species diversity is crucial. Focusing on butterflies, we addressed this question for a cultural-historic landscape in Southern Transylvania, Romania. Following a natural experiment, we randomly selected 120 survey sites in farmland, 60 each in grassland and arable land. We surveyed butterfly species richness and abundance by walking transects with four repeats in summer 2012. We analysed species composition using Detrended Correspondence Analysis. We modelled species richness, richness of functional groups, and abundance of selected species in response to topography, woody vegetation cover and heterogeneity at three spatial scales, using generalised linear mixed effects models. Species composition widely overlapped in grassland and arable land. Composition changed along gradients of heterogeneity at local and context scales, and of woody vegetation cover at context and landscape scales. The effect of local heterogeneity on species richness was positive in arable land, but negative in grassland. Plant species richness, and structural and topographic conditions at multiple scales explained species richness, richness of functional groups and species abundances. Our study revealed high conservation value of both grassland and arable land in low-intensity Eastern European farmland. Besides grassland, also heterogeneous arable land provides important habitat for butterflies. While butterfly diversity in arable land benefits from heterogeneity by small-scale structures, grasslands should be protected from fragmentation to provide

  18. Low intensity laser therapy and functional orthopedics contribution in pain and temporo mandibular dysfunction treatment

    International Nuclear Information System (INIS)

    Lollato, Renata Fronzaglia

    2003-01-01

    Temporo Mandibular Dysfunction (TMD) is a term used to describe disorders which involve temporomandibular joint (TMJ), masticatory muscles, and associated structures, isolatedly or not, whose most frequent symptoms pain. Its etiology involve controversies, and among risk factors is Class 11 malocclusion. A lot of techniques are used for TMD treatment, and the most recent are Low Intensity Laser Therapy (LILT) and Functional Orthopedics (FO). The aim of this study was to evaluate pain and buccal mobility in subjects with Class II malocclusion and TMD symptoms, treated with LILT and FO associated or not. Eighteen subjects were selected and divided in three groups. Group 1 was treated with LILT, λ = 780 nm, 70 mW, 15 J/cm 2 per point, in six sessions during two weeks. The application was in three points around the TMJ and in masticatory muscles: masseter, temporalis, sternomastoid and trapezius, on both sides when there was pain. Palpation was made before and five minutes after application and subjects answered a questionnaire with a score for pain evaluation. Group 2 received functional orthopedics aparatology Planas Indirect Composed Plates, and was evaluated once a week during two weeks, after palpation and following the same score as group 1. Group 3 received both therapies at the same time, and the first application coincided with the aparatology installation. The evaluation followed the parameters of group 1. The results were statically analyzed , and in general form did not show significant differences. There was remission of pain symptoms in ali of the groups, and group 3 showed more rapidly results. This fact leaded us to a conclusion that the association of the LILT with FO was the best treatment for the pain symptoms remission in TMD. (author)

  19. The science of ultrasound therapy for fracture healing

    Directory of Open Access Journals (Sweden)

    Della Rocca Gregory

    2009-01-01

    Full Text Available Fracture healing involves a complex interplay of cellular processes, culminating in bridging of a fracture gap with bone. Fracture healing can be compromised by numerous exogenous and endogenous patient factors, and intense research is currently going on to identify modalities that can increase the likelihood of successful healing. Low-intensity pulsed ultrasound (LIPUS has been proposed as a modality that may have a benefit for increasing reliable fracture healing as well as perhaps increasing the rate of fracture healing. We conducted a review to establish basic scince evidence of therapeutic role of lipus in fracture healing. An electronic search without language restrictions was accomplished of three databases (PubMed, Embase, Cinahl for ultrasound-related research in osteocyte and chondrocyte cell culture and in animal fracture models, published from inception of the databases through December, 2008. Studies deemed to be most relevant were included in this review. Multiple in vitro and animal in vivo studies were identified. An extensive body of literature exists which delineates the mechanism of action for ultrasound on cellular and tissue signaling systems that may be related to fracture healing. Research on LIPUS in animal fracture models has demonstrated promising results for acceleration of fracture healing and for promotion of fracture healing in compromised tissue beds. A large body of cellular and animal research exists which reveals that LIPUS may be beneficial for accelerating normal fracture healing or for promoting fracture healing in compromised tissue beds. Further investigation of the effects of LIPUS in human fracture healing is warranted for this promising new therapy.

  20. Measuring topology of low-intensity DNA methylation sites for high-throughput assessment of epigenetic drug-induced effects in cancer cells

    International Nuclear Information System (INIS)

    Gertych, Arkadiusz; Farkas, Daniel L.; Tajbakhsh, Jian

    2010-01-01

    Epigenetic anti-cancer drugs with demethylating effects have shown to alter genome organization in mammalian cell nuclei. The interest in the development of novel epigenetic drugs has increased the demand for cell-based assays to evaluate drug performance in pre-clinical studies. An imaging-based cytometrical approach that can measure demethylation effects as changes in the spatial nuclear distributions of methylated cytosine and global DNA in cancer cells is introduced in this paper. The cells were studied by immunofluorescence with a specific antibody against 5-methylcytosine (MeC), and 4,6-diamidino-2-phenylindole (DAPI) for delineation of methylated sites and global DNA in nuclei. In the preprocessing step the segmentation of nuclei in three-dimensional images (3-D) is followed by an automated assessment of nuclear DAPI/MeC patterns to exclude dissimilar entities. Next, low-intensity MeC (LIM) and low-intensity DNA (LID) sites of similar nuclei are localized and processed to obtain specific nuclear density profiles. These profiles sampled at half of the total nuclear volume yielded two parameters: LIM 0.5 and LID 0.5 . The analysis shows that zebularine and 5-azacytidine-the two tested epigenetic drugs introduce changes in the spatial distribution of low-intensity DNA and MeC signals. LIM 0.5 and LID 0.5 were significantly different (p < 0.001) in 5-azacytidine treated (n = 660) and zebularine treated (n = 496) vs. untreated (n = 649) DU145 human prostate cancer cells. In the latter case the LIM sites were predominantly found at the nuclear border, whereas treated populations showed different degrees of increase in LIMs towards the interior nuclear space, in which a large portion of heterochromatin is located. The cell-by-cell evaluation of changes in the spatial reorganization of MeC/DAPI signals revealed that zebularine is a more gentle demethylating agent than 5-azacytidine. Measuring changes in the topology of low-intensity sites can potentially be a

  1. Feasibility study of a peer-facilitated low intensity cognitive-behavioral intervention for mild to moderate depression and anxiety in older adults.

    Science.gov (United States)

    Seeley, John R; Manitsas, Tara; Gau, Jeff M

    2017-09-01

    The majority of older adults experiencing depression and/or anxiety do not receive adequate treatment due to limited access to evidence-based practices. Low intensity cognitive-behavioral intervention has been established as an evidence-based practice with the potential to increase the reach to older adults. The purpose of the current study is to evaluate the feasibility, acceptability, and potential efficacy of a low intensity, peer-supported, cognitive-behavioral intervention for mild to moderate depression and/or anxiety delivered by a local intergovernmental agency serving older adults. Sixty-two older adults (81% female) between 55 and 96 years of age were randomly assigned to either a peer-facilitated cognitive-behavioral bibliotherapy condition (n = 31) or a wait-list control condition (n = 31). The 10-week feasibility trial data indicated that (1) a majority of the participants were highly engaged in the intervention with an average number of 7.3 peer sessions attended and 2.1 workbooks completed, (2) the participants were quite satisfied with the peer mentoring sessions and moderately satisfied with the workbooks, and (3) there were clinically meaningful reductions in depressive symptoms for those assigned to the treatment condition compared to those that were wait-listed (d = .43), though the effect was non-significant (p = .099) due to the small sample size. The evidence for the impact on reducing anxiety symptoms was more equivocal with a non-significant, small effect size favoring the treatment condition. The pilot study provided preliminary evidence for the feasibility, acceptability, and potential efficacy of the peer-facilitated low intensity cognitive-behavioral therapy intervention approach.

  2. Clinical evaluation of the low intensity laser antialgic action of GaAlAs (λ=785 nm) in the treatment of the temporomandibular disorders

    International Nuclear Information System (INIS)

    Sanseverino, Nelly Tichauer Maluf

    2001-01-01

    The therapy with laser emitting low intensity has been currently used in the most diverse fields of medicine as therapeutic conduct for pain. It is a non invasive, painless, non-thermal and aseptic type therapy, without any collateral effects, having a good cost/benefit relationship. However, for the therapy with low-intensity laser to result in positive effects, a correct diagnosis is fundamental, as well as a protocol of adequate application. n odontology, the majority of patients diagnosed with temporomandibular disorders (TMD), present pain and limitations in the movements of the jaw. In this work, a GaAlAs laser emitting low intensity, was used, λ=785 nm, in patients having a dysfunction of the temporomandibular joint with a complaint of pain. Twenty patients were divided into two groups. The group treated received laser therapy in the temporomandibular articulations and in the muscles affected. The dose applied was 45 J/cm 2 , while the ten patients in the control group received 0 J/cm 2 , in a total of nine applications, carried out three times a week, during three weeks. he evaluation of the patients was made through clinical examinations of manual palpation of the masseter, temporal, cervical, posterior neck and sternocleidomastoid muscles, and measurements of opening and laterality of the mouth. The results obtained showed a diminishing of the pain and an increase of the mandibular mobility in the patients treated, when compared to the control group. These results point to this therapy as being an important tool in the treatment of pain in patients with a dysfunction in the TMJ, indicating this therapeutic modality as a co-adjuvant in these treatments. (author)

  3. Fetal Ultrasound

    Science.gov (United States)

    ... isn't recommended simply to determine a baby's sex. Similarly, fetal ultrasound isn't recommended solely for the purpose of producing keepsake videos or pictures. If your health care provider doesn' ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... nodule felt by a physician during a routine physical exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ... well on x-ray images. Ultrasound causes no health problems and may be repeated as often as ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... no ionizing radiation. Ultrasound scanning may be able to give a clearer picture of soft tissues that do ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... use different transducers (with different capabilities) during a single exam. The transducer sends out high-frequency sound ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is located directly in front of the rectum, so the ultrasound exam is performed transrectally in order ... A follow-up examination may also be necessary so that any change in a known abnormality can ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the rectal wall is relatively insensitive to the pain in the region of the prostate. A biopsy ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... diagnose symptoms such as difficulty urinating or an elevated blood test result. It’s also used to investigate ... physical exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible ... principles involved in the sonar used by bats, ships and fishermen. When a sound wave strikes an ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ... make secure contact with the body and eliminate air pockets between the transducer and the skin that ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... a follow-up exam is done because a potential abnormality needs further evaluation with additional views or ... of soft tissues that do not show up well on x-ray images. Ultrasound causes no health ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a follow-up exam is done because a potential abnormality needs further evaluation with additional views or ... of soft tissues that do not show up well on x-ray images. Ultrasound is the preferred ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is smaller than the standard speculum used when performing a Pap test . A protective cover is placed ... of soft tissues that do not show up well on x-ray images. Ultrasound is the preferred ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... scanning or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... scanning or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on ... the child prior to the exam. Bringing books, small toys, music or games can help to distract ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... less than 20 minutes. top of page What will I experience during and after the procedure? Ultrasound ... in the region of the prostate. A biopsy will add time to the procedure. Rarely, a small ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are reviewed. top of page What will I experience during and after the procedure? For ... in the region of the prostate. A biopsy will add time to the procedure. If a Doppler ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... arteries and veins in the abdomen, arms, legs, neck and/or brain (in infants and children) or ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the best way to see if treatment is working or if a finding is stable or changed ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . ... move through vessels. The movement of blood cells causes a change in pitch of the reflected sound ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs such ... and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time imaging, making it a ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... move through vessels. The movement of blood cells causes a change in pitch of the reflected sound ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  16. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... frequently used to evaluate the reproductive and urinary systems. Ultrasound is safe, noninvasive and does not use ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... be asked to drink water prior to the examination to fill your bladder. Leave jewelry at home ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Prostate Cancer top of page ... to Ultrasound - Prostate Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... with measurements acquired as needed for any treatment planning. detect an abnormal growth within the prostate. help ... end of their bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... tip of the transducer is smaller than the standard speculum used when performing a Pap test . A ... both sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... prostate gland and to help diagnose symptoms such as difficulty urinating or an elevated blood test result. ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in the abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs ... or uterine cancers A transvaginal ultrasound is usually performed to view ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is enlarged, also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any treatment ... caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) (Enlargement of the Prostate) Prostate Cancer Ultrasound- and ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the exam. Bringing books, small toys, music or games can help to distract the child and make ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the examination process. To ensure a smooth experience, it often helps to explain the procedure to the ... on the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... difficulty urinating or an elevated blood test result. It’s also used to investigate a nodule found during ... difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide procedures such ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ... and Resources RTAnswers.org Radiation Therapy for Prostate Cancer top of page This page was reviewed on ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ... and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... legs, neck and/or brain (in infants and children) or within various body organs such as the ... tumors other disorders of the urinary bladder In children, pelvic ultrasound can help evaluate: pelvic masses pelvic ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterus). Sonohysterography allows for a more in-depth investigation of the uterine cavity . Three-dimensional (3-D) ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is Pelvic Ultrasound Imaging? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... quickly. The ultrasound exam room may have a television. Feel free to ask for your child's favorite ... display screen that looks like a computer or television monitor. The image is created based on the ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Prostate Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Pelvis Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... The ultrasound exam room may have a television. Feel free to ask for your child's favorite channel. ... performed over an area of tenderness, you may feel pressure or minor pain from the transducer. Once ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any treatment planning. detect ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view ... detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... kidneys. top of page What are some common uses of the procedure? In women, a pelvic ultrasound ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... various body organs such as the liver or kidneys. top of page What are some common uses ... women, a pelvic ultrasound exam can help identify: kidney stones bladder tumors other disorders of the urinary ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls of the uterus). Sonohysterography allows for a ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is at high risk for cancer. In this case, a biopsy is performed and an ultrasound probe ... will share the results with you. In some cases, the radiologist may discuss results with you at ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls of the uterus). Sonohysterography allows for a more ... needle insertion) is usually minimal because the rectal wall is relatively insensitive to the pain in the ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... pain ambiguous genitalia and anomalies of pelvic organs early or delayed puberty in girls Pelvic ultrasound is ... sensitive to motion, and an active or crying child can prolong the examination process. To ensure a ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... consist of a console containing a computer and electronics, a video display screen and a transducer that ... the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  19. Low intensity radiation in diapazone of high frequency as factor of the survival modification of differentiated plant cells

    International Nuclear Information System (INIS)

    Tordiya, N.V.

    2005-01-01

    The combined effect of low intensity electromagnetic emission in high frequency range (EMI HF) and ionizing radiation on survival of the differential cells of high plant water Elodea canadensis is investigated. It was established, that EMI HF is radioprotective modification of the radiation injury of plant cell

  20. Low intensity behavioral treatment supplementing preschool services for young children with autism spectrum disorders and severe to mild intellectual disability

    NARCIS (Netherlands)

    Peters-Scheffer, N.C.; Didden, H.C.M.; Mulders, M.; Korzilius, H.P.L.M.

    2010-01-01

    This study evaluated the effectiveness of low intensity behavioral treatment (on average 6.5 h per week) supplementing preschool services in 3-6-year-old children with autism spectrum disorder and severe to mild intellectual disability. Treatment was implemented in preschools (i.e., daycare centers)

  1. Investigation of the cellular effects of Low Intensity Laser Irradiation (LILI)

    International Nuclear Information System (INIS)

    Esfandiary, H.

    1998-07-01

    Low Intensity Laser Irradiation (LILI) has become a therapeutic modality for the treatment of various conditions including acceleration of wound healing. Despite extensive experimental cellular research, the biological mechanisms underlying the success of this phenomenon remain unknown. This, in combination with the conflicting reported clinical results of LILI have prevented universal acceptance of this modality by health care professions. The aim of this thesis was to investigate further, in a systematic and well-controlled manner, the biological effects of LILI on two human leukaemic cell lines HL-60 and U937 in vitro. The laser diode used was a Gallium Aluminium Arsenide (GaAlAs) laser with a wavelength of 660nm, output power of 12mW and a chosen therapeutic energy density of 11.5J/cm 2 . Initially, intracellular thermal effects were examined following LILI by monitoring levels of several heat shock protein (hsp) family members over a 24h period. Levels of hsp70, 60, 90 and 27 were unaffected at the chosen LILI energy density of 11.5J/cm 2 . The effect of LILI on the cell cycle was also investigated at the molecular level by probing for protein and mRNA of a number of cell cycle regulatory factors. Levels of p53, c-fos, c-myc hsp70, bcl-2, TNF-α and several others was unaffected by LILI. Finally, the differential display method was used to detect any LILI-induced transcriptional changes in mRNA i.e. altered gene expression and again results were negative with LILI having no effect on gene expression. In conclusion, these results suggest that the biological effects of GaAlAs lasers at an E.D. of 11.5/cm 2 on two human leukaemic cell lines in vitro do not involve a stress response as measured by hsps, do not modulate levels of prominent cell cycle factors and do not induce changes in gene expression at the transcriptional level. These results seriously question the effectiveness of low energy lasers as 'real' therapeutic devices due to lack of any LILI

  2. Low intensity interventions for Obsessive-Compulsive Disorder (OCD): a qualitative study of mental health practitioner experiences.

    Science.gov (United States)

    Gellatly, Judith; Pedley, Rebecca; Molloy, Christine; Butler, Jennifer; Lovell, Karina; Bee, Penny

    2017-02-22

    Obsessive-compulsive disorder (OCD) is a debilitating mental health disorder that can substantially impact upon quality of life and everyday functioning. Guidelines recommend pharmacological and psychological treatments, using a cognitive behaviour therapy approach (CBT) including exposure and response prevention, but access has generally been poor. Low intensity psychological interventions have been advocated. The evidence base for these interventions is emerging but there is a paucity of information regarding practitioners' perceptions and experiences of supporting individuals with OCD using this approach. Qualitative interviews were undertaken with psychological wellbeing practitioners (PWPs) (n = 20) delivering low intensity psychological interventions for adults with OCD within the context of a large pragmatic effectiveness trial. Interviews explored the feasibility and acceptability of delivering two interventions; guided self-help and supported computerised cognitive behaviour therapy (cCBT), within Improving Access to Psychological Therapies (IAPT) services in NHS Trusts. Interviews were recorded with consent, transcribed and analysed using thematic analysis. PWPs acknowledged the benefits of low intensity psychological interventions for individuals experiencing OCD symptoms on an individual and population level. Offering low intensity support provided was perceived to have the opportunity to overcome existing service barriers to access treatment, improve patient choice and flexibility. Professional and service relevant issues were also recognised including self-beliefs about supporting people with OCD and personal training needs. Challenges to implementation were recognised in relation to practitioner resistance and intervention delivery technical complications. This study has provided insight into the implementation of new low intensity approaches to the management of OCD within existing mental health services. Benefits from a practitioner, service

  3. The development and evaluation of ultrasound for the treatment of bacterial suspensions. A study of frequency, power and sonication time on cultured Bacillus species.

    Science.gov (United States)

    Joyce, E; Phull, S S; Lorimer, J P; Mason, T J

    2003-10-01

    Some species of bacteria produce colonies and spores which agglomerate in spherical clusters (Bacillus subtilis) and this serves as a protection for the organisms inside against biocidal attack. Flocs of fine particles e.g. clay can entrap bacteria which can also protect them against the biocides. It is because of problems such as these that alternative methods of disinfecting water are under active investigation. One such method is the use of power ultrasound, either alone or in combination with other methods. Ultrasound is able to inactivate bacteria and deagglomerate bacterial clusters or flocs through a number of physical, mechanical and chemical effects arising from acoustic cavitation. The aim of this study was to investigate the effect of power ultrasound at different powers and frequencies on Bacillus subtilis. Viable plate count techniques were used as a measure of microbial activity. Results showed a significant increase in percent kill for Bacillus species with increasing duration of exposure and intensity of ultrasound in the low-kilohertz range (20 and 38 kHz). Results obtained at two higher frequencies (512 and 850 kHz) indicated a significant increase in bacteria count suggesting declumping. In assessing the bacterial kill with time under different sonication regimes three types of behaviour were characterized: High power ultrasound (lower frequencies) in low volumes of bacterial suspension results in a continuous reduction in bacterial cell numbers i.e. the kill rate predominates. High power ultrasound (lower frequencies) in larger volumes results in an initial rise in cell numbers suggesting declumping of the bacteria but this initial rise then falls as the declumping finishes and the kill rate becomes more important. Low intensity ultrasound (higher frequencies) gives an initial rise in cell numbers as a result of declumping. The kill rate is low and so there is no significant subsequent decrease in bacterial cell numbers.

  4. Cranial Ultrasound/Head Ultrasound

    Science.gov (United States)

    ... used to screen for brain conditions associated with prematurity, such as bleeding or brain tissue damage as ... or crying child will slow the examination process. Large patients are more difficult to image by ultrasound, ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart ... Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and ... be heard with every heartbeat. top of page What are some common uses of the procedure? Ultrasound ...

  10. [The combined action of drinking mineral water and low-intensity electromagnetic radiation under the immobilization stress conditions (an experimental study)].

    Science.gov (United States)

    Korolev, Yu N; Bobrovnitsky, I P; Geniatulina, M S; Mikhailik, L V; Nikulina, L A; Bobkova, A S; Yakovlev, M Yu

    2015-01-01

    The present study carried out on white male rats in experiments with the use of biochemical, radioimmunological, and electron- microscopic methods. It was shown that the combined treatment with potable mineral water (MV) and low-intensity electromagnetic radiation (LIEMR) of ultrahigh frequency (power density less than 1 pW/cm2, the frequency about 1000 MHz) facilitated the activation of metabolic and intracellular regenerative processes in the liver and testes. One of the advantages of the combined application of MV and LIEMR over the single-factor treatment manifested itself as the weakening of stress reactions, the increase in the frequency of the plastic processes, and the more harmonious development of different forms of intracellular regeneration. The results of the study provide a deeper insight ino the mechanisms underlying the combined actions of drinking mineral water and low-intensity electromagnetic radiation; also, they justify the application of these factors for the protection of the reproductive system and the entire body from stress-induced disorders.

  11. High- but not low-intensity light leads to oxidative stress and quality loss of cold-stored baby leaf spinach.

    Science.gov (United States)

    Glowacz, Marcin; Mogren, Lars M; Reade, John P H; Cobb, Andrew H; Monaghan, James M

    2015-07-01

    Quality management in the fresh produce industry is an important issue. Spinach is exposed to various adverse conditions (temperature, light, etc.) within the supply chain. The present experiments were conducted to investigate the effect of light conditions (dark, low-intensity light (LL) and high-intensity light (HL)) and photoperiod (6 h HL and 18 h dark) on the quality changes of cold-stored spinach. HL exposure resulted in oxidative stress, causing tissue damage and quality loss as evidenced by increased membrane damage and water loss. The content of total ascorbic acid was reduced under HL conditions. On the other hand, storage of spinach under LL conditions gave promising results, as nutritional quality was not reduced, while texture maintenance was improved. No significant differences, with the exception of nutritional quality, were found between spinach leaves stored under continuous (24 h) low-intensity light (30-35 µmol m(-2) s(-1)) and their counterparts stored under the same light integral over 6 h (130-140 µmol m(-2) s(-1)). LL extended the shelf-life of spinach. The amount of light received by the leaves was the key factor affecting produce quality. Light intensity, however, has to be low enough not to cause excess oxidative stress and lead to accelerated senescence. © 2014 Society of Chemical Industry.

  12. Bioeffects of low-energy continuous ultrasound on isolated sarcoma 180 cells.

    Science.gov (United States)

    Wang, Xiaobing; Liu, Quanhong; Wang, Zhezhi; Wang, Pan; Hao, Qiao; Li, Chendi

    2009-01-01

    The aim of this study was to investigate the mechanism underlying bioeffects of low-intensity continuous ultrasound on isolated sarcoma 180 (S180) cells and cellular responses to these effects. After sonication, several structural and functional parameters were examined to elucidate ultrasound-induced cell damage. Instant disruption of the cell membrane might be caused by acoustic cavitation, producing mechanical and chemical effects that acted simultaneously on S180 cells; this could be reflected by immediate (morphological) changes such as membrane permeability, membrane fluidity, lipid peroxidation and the generation of hydroxyl radicals in culture medium. Our results of the delayed effects also indicated S180 cells were sensitive to ultrasound-induced apoptosis, and the rate of apoptosis rose gradually with a prolonged incubation time. The presence of apoptotic cells was identified by a distinct morphological form characterized by membrane blebbing, cell shrinkage, chromatin condensation and DNA fragmentation. Moreover, delayed cytotoxicity was accompanied by an increase in intracellular reactive oxygen species (ROS) and a decrease in the mitochondrial membrane potential, and the two events presented obviously a negative correlation. ROS secondarily generated from damaged mitochondria may play a role in the induction of apoptosis. Copyright 2009 S. Karger AG, Basel.

  13. Therapeutic ultrasound

    International Nuclear Information System (INIS)

    Crum, Lawrence A

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  14. Associations of Low-Intensity Resistance Training with Body Composition and Lipid Profile in Obese Patients with Type 2 Diabetes.

    Science.gov (United States)

    Hamasaki, Hidetaka; Kawashima, Yu; Tamada, Yoshiki; Furuta, Masashi; Katsuyama, Hisayuki; Sako, Akahito; Yanai, Hidekatsu

    2015-01-01

    Resistance training to increase muscle mass and functional capacity is an integral part of diet and exercise programs for the management of obesity and type 2 diabetes. Low-intensity resistance training with slow movement and tonic force generation (LST) may be a practical and safe regimen for elderly obese individuals but the health benefits are uncertain. This study investigated the effects of LST on body composition and metabolic parameters in obese patients with type 2 diabetes. Twenty-six obese patients with type 2 diabetes engaged in LST training during hospitalization and were advised to maintain this regimen for 12 weeks after discharge. We compared lipid profile, arterial stiffness, and body composition before and after LST training. After 12 weeks of LST training, the ratio of lower extremity muscle mass to body weight increased significantly (0.176 ± 0.028 to 0.184 ± 0.023, mean ± SD), while body fat mass and body fat percentage decreased significantly (36.2 ± 10.9 kg to 34.3 ± 9.4 kg and 41.2 ± 8.6% to 40.1 ± 7.7%, respectively). Moreover, high-density lipoprotein cholesterol was significantly increased (42.2 ± 14 mg/dl to 46.3 ± 12.4 mg/dl) and both free fatty acids and lipoprotein(a) were decreased (665.2 ± 212.1 μEq/l to 525.4 ± 231.3 μEq/l and 15.4 ± 18 mg/dl to 13.8 ± 18 mg/dl, respectively). No significant change was observed in arterial stiffness. Although this study was a non-controlled investigation and some confounding factors including dietary intake, medication and compliance with training might affect the study result, a brief (12-week) LST training program may be a safe and effective strategy for the management of obesity and type 2 diabetes.

  15. Associations of Low-Intensity Resistance Training with Body Composition and Lipid Profile in Obese Patients with Type 2 Diabetes.

    Directory of Open Access Journals (Sweden)

    Hidetaka Hamasaki

    Full Text Available Resistance training to increase muscle mass and functional capacity is an integral part of diet and exercise programs for the management of obesity and type 2 diabetes. Low-intensity resistance training with slow movement and tonic force generation (LST may be a practical and safe regimen for elderly obese individuals but the health benefits are uncertain. This study investigated the effects of LST on body composition and metabolic parameters in obese patients with type 2 diabetes. Twenty-six obese patients with type 2 diabetes engaged in LST training during hospitalization and were advised to maintain this regimen for 12 weeks after discharge. We compared lipid profile, arterial stiffness, and body composition before and after LST training. After 12 weeks of LST training, the ratio of lower extremity muscle mass to body weight increased significantly (0.176 ± 0.028 to 0.184 ± 0.023, mean ± SD, while body fat mass and body fat percentage decreased significantly (36.2 ± 10.9 kg to 34.3 ± 9.4 kg and 41.2 ± 8.6% to 40.1 ± 7.7%, respectively. Moreover, high-density lipoprotein cholesterol was significantly increased (42.2 ± 14 mg/dl to 46.3 ± 12.4 mg/dl and both free fatty acids and lipoprotein(a were decreased (665.2 ± 212.1 μEq/l to 525.4 ± 231.3 μEq/l and 15.4 ± 18 mg/dl to 13.8 ± 18 mg/dl, respectively. No significant change was observed in arterial stiffness. Although this study was a non-controlled investigation and some confounding factors including dietary intake, medication and compliance with training might affect the study result, a brief (12-week LST training program may be a safe and effective strategy for the management of obesity and type 2 diabetes.

  16. Method for Correction of Consequences of Radiation-Induced Heart Disease using Low-Intensity Electromagnetic Emission under Experimental Conditions.

    Science.gov (United States)

    Bavrina, A P; Monich, V A; Malinovskaya, S L; Yakovleva, E I; Bugrova, M L; Lazukin, V F

    2015-05-01

    Effects of successive exposure to ionizing irradiation and low-intensity broadband red light on electrical activity of the heart and myocardium microstructure were studied in rats. Lowintensity red light corrected some ECG parameters, in particular, it normalized QT and QTc intervals and voltage of R and T waves. Changes in ECG parameters were followed by alterations in microstructure of muscle fi laments in the myocardium of treatment group animals comparing to control group.

  17. Ultrasound appearance of knuckle pads

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Ben, R. [Univ. of Alabama, Birmingham (United States). Dept. of Diagnostic Radiology; Dehghanpisheh, K.; Chatham, W.W.; Alarcon, G.S. [Univ. of Alabama, Birmingham (United States). Dept. of Medicine; Lee, D.H.; Oakes, J. [Univ. of Alabama, Birmingham (United States). Dept. of Surgery

    2006-11-15

    We describe the ultrasound appearance of knuckle pads. Retrospective analysis of imaging in a series of five patients initially referred for evaluation of periarticular soft-tissue swelling of the hands involving the dorsum of the PIP and MP joints. Two patients had associated Dupuytren's contractures. Ultrasound and radiographs of the hands in all patients were reviewed and correlated with clinical history and physical exams. Radiographs in four patients demonstrated dorsal soft-tissue thickening. Ultrasound exams showed increased dorsal subcutaneous thickening, with either diffuse or focal hypoechoic areas corresponding to the areas of soft-tissue fullness identified on physical exam. No erosions or synovial proliferation were identified either by radiographs or ultrasound of the underlying joints. Knuckle pads can sometimes be difficult to distinguish from synovitis on physical examination. Musculoskeletal ultrasound can quickly identify these superficial lesions and exclude underlying synovial proliferation.

  18. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  19. Influence of low-intensity laser therapy on spatial perception threshold and electroneurographic finding in patients with diabetic polyneuropathy

    Directory of Open Access Journals (Sweden)

    Perić Zoran

    2007-01-01

    Full Text Available Introduction: Low-intensity laser therapy (LILT can be applied in cases when patients with diabetic polyneuropathy (DPN suffer from chronic severe neuropathic pain. Objective. We wanted to analyze influence of LILT on spatial perception threshold (SPT and electroneurographic (ENG parameters in patients with painful DPN. Method. We analyzed 45 patients (25 males, average age 54.3 years (54.3±10.9, with clinical and ENG signs of painful DPN. The patients were divided into two groups: A and B. Group A consisted of 30 patients with DPN who had 30 LILT treatments over the period of 12 weeks and group B consisted of 15 patients with DPN who received only vitamin therapy per os within the same period. Prior to and after 12 weeks of treatment, the following ENG parameters were determined using surface electrodes: motor (MCV and sensory conduction velocities (SCV values (in m/s of nervus (n. peroneus (NP, n. tibialis (NT and n. medianus (NM and their motor distal latency (MDL values (in ms. SPT value (score as number from 1 to 8 was determined with Tactile Circumferential Discriminator on dorsal part of foot’s big toe skin. For statistical analysis, we used Student’s t-test and Pearson correlation (sig. 2 tailed study. Results. We registered statistically significant difference between SPT (p<0.01 values prior to (5.25±1.11 and after (4.87±0.90 LILT, as well as NMMCV (p<0.05 values prior to (47.18±5.08 and after (49.12±3.72 LILT. Besides, we registered, only after LILT, statistically significant correlation between SPT and NMDML (p<0.01 values and also between SPT and NMSCV (p<0.05 values. The differences and correlations between other analyzed parameters before and after treatments were not significant (p>0.05. Conclusion. In this study we registered significant decrease of SPT and increase of NMMCV after LILT and that indicated a favorable effect of this treatment in analyzed patients with painful DPN. In our opinion these results need further

  20. Effect of Low-intensity Exercise on Physical and Cognitive Health in Older Adults: a Systematic Review.

    Science.gov (United States)

    Tse, Andy C Y; Wong, Thomson W L; Lee, Paul H

    It is well known that physical exercise is important to promote physical and cognitive health in older population. However, inconsistent research findings were shown regarding exercise intensity, particularly on whether low-intensity exercise (1.5 metabolic equivalent tasks (METs) to 3.0 METs) can improve physical and cognitive health of older adults. This systematic review aimed to fill this research gap. The objective of this study is to conduct a systematic review of the effectiveness of low-intensity exercise interventions on physical and cognitive health of older adults. Published research was identified in various databases including CINAHL, MEDLINE, PEDro, PubMed, Science Direct, SPORTDiscus, and Web of Science. Research studies published from January 01, 1994 to February 01, 2015 were selected for examination. Studies were included if they were published in an academic peer-reviewed journal, published in English, conducted as randomized controlled trial (RCT) or quasi-experimental studies with appropriate comparison groups, targeted participants aged 65 or above, and prescribed with low-intensity exercise in at least one study arm. Two reviewers independently extracted the data (study, design, participants, intervention, and results) and assessed the quality of the selected studies. Fifteen studies met the inclusion criteria. Quality index ranged from 15 to 18 mean = 18.3 with a full score of 28, indicating a moderate quality. Most of the outcomes reported in these studied were lower limb muscle strength ( n  = 9), balancing ( n  = 7), flexibility ( n  = 4), and depressive symptoms ( n  = 3). Out of the 15 selected studies, 11 reported improvement in flexibility, balancing, lower limb muscle strength, or depressive symptoms by low-intensity exercises. The current literature suggests the effectiveness of low-intensity exercise on improved physical and cognitive health for older adults. It may be a desired intensity level in promoting

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of the prostate gland is typically used to help diagnose symptoms such as: a nodule felt by a physician during a routine physical exam or prostate cancer screening exam. an elevated ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... body tissue through which the sound travels. A small amount of gel is put on the skin to allow the sound waves to travel from the transducer to the examined area within the body and then back again. Ultrasound ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... body tissue through which the sound travels. A small amount of gel is put on the skin to allow the sound waves to travel from the transducer to the examined area within the body and then back again. Ultrasound ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during pregnancy. See the ... can help to identify and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and creates graphs ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally ... known harmful effects on humans. top of page What are the ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... symptoms such as difficulty urinating or an elevated blood test result. It’s also used to investigate a nodule ... exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in which needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician to see and evaluate: blockages to blood flow (such as clots) narrowing of vessels tumors ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide procedures such as needle biopsies , in which a needle is used to sample cells (tissue) from an abnormal area in the ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the ... tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the ... tissues that do not show up well on x-ray images. Ultrasound is the preferred imaging modality for ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from the area within the patient that is being examined to the transducer (the device placed on the patient's skin to send and ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from the area within the patient that is being examined to the transducer (the device placed on the patient's skin to send and ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... by a computer, which in turn creates a real-time picture on the monitor. One or more frames ...

  16. Obstetrical ultrasound

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The use of diagnostic ultrasound in obstetrics may provide fuel for legal action. While most legal implications of this relatively new imaging modality are purely speculative, some have already given rise to legal action. Several situations will likely provide a basis for the courts to find against the physician. The failure to perform a sonogram when clinically indicated will most likely be the strongest plaintiff argument. Other major concerns include the use and availability of state-of-the-art equipment, as well as interpretation of the scans by a trained physician. Obstetrical ultrasound is usually performed by a radiologist or obstetrician. However, many physicians performing these examinations have had little or no formal training in the field. While this is now being remedied by the respective board examines who require a certain amount of training, it may not be enough. When ultrasound-related cases reach the courts, the involved physicians will most likely be regarded as experts in the field and, therefore, will be held to a very high standard of care. This would be difficult to achieve without formal training. At the present time, the American Board of Radiology requires more training time in ultrasound than the American Board of Obstetrics and Gynecology

  17. Research interface on a programmable ultrasound scanner.

    Science.gov (United States)

    Shamdasani, Vijay; Bae, Unmin; Sikdar, Siddhartha; Yoo, Yang Mo; Karadayi, Kerem; Managuli, Ravi; Kim, Yongmin

    2008-07-01

    Commercial ultrasound machines in the past did not provide the ultrasound researchers access to raw ultrasound data. Lack of this ability has impeded evaluation and clinical testing of novel ultrasound algorithms and applications. Recently, we developed a flexible ultrasound back-end where all the processing for the conventional ultrasound modes, such as B, M, color flow and spectral Doppler, was performed in software. The back-end has been incorporated into a commercial ultrasound machine, the Hitachi HiVision 5500. The goal of this work is to develop an ultrasound research interface on the back-end for acquiring raw ultrasound data from the machine. The research interface has been designed as a software module on the ultrasound back-end. To increase the amount of raw ultrasound data that can be spooled in the limited memory available on the back-end, we have developed a method that can losslessly compress the ultrasound data in real time. The raw ultrasound data could be obtained in any conventional ultrasound mode, including duplex and triplex modes. Furthermore, use of the research interface does not decrease the frame rate or otherwise affect the clinical usability of the machine. The lossless compression of the ultrasound data in real time can increase the amount of data spooled by approximately 2.3 times, thus allowing more than 6s of raw ultrasound data to be acquired in all the modes. The interface has been used not only for early testing of new ideas with in vitro data from phantoms, but also for acquiring in vivo data for fine-tuning ultrasound applications and conducting clinical studies. We present several examples of how newer ultrasound applications, such as elastography, vibration imaging and 3D imaging, have benefited from this research interface. Since the research interface is entirely implemented in software, it can be deployed on existing HiVision 5500 ultrasound machines and may be easily upgraded in the future. The developed research

  18. Initial laboratory experience with a novel ultrasound probe for standard and single-port robotic kidney surgery: increasing console surgeon autonomy and minimizing instrument clashing.

    Science.gov (United States)

    Yakoubi, Rachid; Autorino, Riccardo; Laydner, Humberto; Guillotreau, Julien; White, Michael A; Hillyer, Shahab; Spana, Gregory; Khanna, Rakesh; Isaac, Wahib; Haber, Georges-Pascal; Stein, Robert J; Kaouk, Jihad H

    2012-06-01

    The aim of this study was to evaluate a novel ultrasound probe specifically developed for robotic surgery by determining its efficiency in identifying renal tumors. The study was carried out using the Da Vinci™ surgical system in one female pig. Renal tumor targets were created by percutaneous injection of a tumor mimic mixture. Single-port and standard robotic partial nephrectomy were performed. Intraoperative ultrasound was performed using both standard laparoscopic probe and the new ProART™ Robotic probe. Probe maneuverability and ease of handling for tumor localization were recorded. The standard laparoscopic probe was guided by the assistant. Significant clashing with robotic arms was noted during the single-port procedure. The novel robotic probe was easily introduced through the assistant trocar, and held by the console surgeon using the robotic Prograsp™ with no registered clashing in the external operative field. The average time for grasping the new robotic probe was less than 10 s. Once inserted and grasped, no limitation was found in terms of instrument clashing during the single-port procedure. This novel ultrasound probe developed for robotic surgery was noted to be user-friendly when performing porcine standard and especially single-port robotic partial nephrectomy. Copyright © 2011 John Wiley & Sons, Ltd.

  19. Ultrasound enhanced delivery of molecular imaging and therapeutic agents in Alzheimer's disease mouse models.

    Directory of Open Access Journals (Sweden)

    Scott B Raymond

    Full Text Available Alzheimer's disease is a neurodegenerative disorder typified by the accumulation of a small protein, beta-amyloid, which aggregates and is the primary component of amyloid plaques. Many new therapeutic and diagnostic agents for reducing amyloid plaques have limited efficacy in vivo because of poor transport across the blood-brain barrier. Here we demonstrate that low-intensity focused ultrasound with a microbubble contrast agent may be used to transiently disrupt the blood-brain barrier, allowing non-invasive, localized delivery of imaging fluorophores and immunotherapeutics directly to amyloid plaques. We administered intravenous Trypan blue, an amyloid staining red fluorophore, and anti-amyloid antibodies, concurrently with focused ultrasound therapy in plaque-bearing, transgenic mouse models of Alzheimer's disease with amyloid pathology. MRI guidance permitted selective treatment and monitoring of plaque-heavy anatomical regions, such as the hippocampus. Treated brain regions exhibited 16.5+/-5.4-fold increase in Trypan blue fluorescence and 2.7+/-1.2-fold increase in anti-amyloid antibodies that localized to amyloid plaques. Ultrasound-enhanced delivery was consistently reproduced in two different transgenic strains (APPswe:PSEN1dE9, PDAPP, across a large age range (9-26 months, with and without MR guidance, and with little or no tissue damage. Ultrasound-mediated, transient blood-brain barrier disruption allows the delivery of both therapeutic and molecular imaging agents in Alzheimer's mouse models, which should aid pre-clinical drug screening and imaging probe development. Furthermore, this technique may be used to deliver a wide variety of small and large molecules to the brain for imaging and therapy in other neurodegenerative diseases.

  20. Improvement of localised corrosion resistance of AISI 2205 Duplex Stainless Steel joints made by gas metal arc welding under electromagnetic interaction of low intensity

    Science.gov (United States)

    García-Rentería, M. A.; López-Morelos, V. H.; García-Hernández, R.; Dzib-Pérez, L.; García-Ochoa, E. M.; González-Sánchez, J.

    2014-12-01

    The resistance to localised corrosion of AISI 2205 duplex stainless steel plates joined by Gas Metal Arc Welding (GMAW) under the effect of electromagnetic interaction of low intensity (EMILI) was evaluated with sensitive electrochemical methods. Welds were made using two shielding gas mixtures: 98% Ar + 2% O2 (M1) and 97% Ar + 3% N2 (M2). Plates were welded under EMILI using the M1 gas with constant welding parameters. The modified microstructural evolution in the high temperature heat affected zone and at the fusion zone induced by application of EMILI during welding is associated with the increase of resistance to localised corrosion of the welded joints. Joints made by GMAW using the shielding gas M2 without the application of magnetic field presented high resistance to general corrosion but high susceptibility to undergo localised attack.

  1. Comparison of Two Intensities of Aerobic Training (low intensity and High Intensity on Expression of Perlipin 2 Skeletal Muscle, Serum Glucose and Insulin levels in Streptozotocin-Diabetic Rats

    Directory of Open Access Journals (Sweden)

    M Ghafari

    2017-06-01

    Full Text Available Abstract   Background & aim: Lipid metabolism disorder plays an important role in insulin resistance in skeletal muscle and lipid drop proteins such as perlipine 2 (PLIN2 are effective in regulating intracellular fat metabolism. One of the suggested pathways for the effects of endurance activity in metabolic diseases is the effect of physical activity on intramuscular. Therefore, the purpose of this study was compare the intensity of aerobic exercise intensity (low intensity and high intensity on expression of PLIN2 skeletal muscle, serum glucose and insulin levels in streptozotocin-diabetic rats.   Methods: In this experimental study, 24 male Wistar rats were randomly divided into three groups of 8, including two intervention groups (low intensity endurance training group and high intensity continuous exercise group and one control group. After induction of diabetic rats by injection streptozotocin (55 mg / kg body weight, Intraperitoneally, endurance training was applied for eight weeks, three sessions per week in diabetic rats. Exercise intensity in the low-intensity group was equal to 5-8 m / min (equivalent to 50-60% Vo2max, the intensity of training in a high intensity training group was equivalent to a speed of 22-25 m / min (equivalent to 80% Vo2max and the control group did not receive intervene in this time. Relative protein expression of PLIN2 was performed using western blot technique. Data were analyzed by one-way ANOVA and Tukey's post hoc test.   Results: The results of the intergroup comparison revealed a significant difference among three groups in the PLIN2 variables (p = 0.037. The results of post hoc test showed a significant increase in PLIN2 in high intensity training diabetic group compared to the control group (p = 0.033 However, there was no significant difference in PLIN2 level in the low exercise group compared to the control group (p = 0.18. Also, there was no significant difference between the low intensity and

  2. Influence of continuous microwave irradiation of low intensity on the behaviour of albino rats

    International Nuclear Information System (INIS)

    Rynskov, V.V.

    1985-01-01

    A study was made of a single 10 min exposure of albino rats to microwaves (6 GHz, 0.2 MW/cm 2 ) on their orientative-trying reaction. The locomotive activity, attentiveness and trying activity of the experimental animals were found to increase

  3. The influence of chronic gamma-radiation of low intensity on Bombyx mori L. embryogenesis

    International Nuclear Information System (INIS)

    Yusifov, N.I.; Kuzin, A.M.; Agaev, F.A.; AN Azerbajdzhanskoj SSR, Baku

    1989-01-01

    γ-Irradiation of a grain during embryogenesis at an intensity only 100 times exceeding that of the natural radioactive background reduces by 4-7 h the average time of embryogenesis for different species and hybrides of the grain. The 10- and 40-time increase in the radiation intensity decreases the stimulatory effect and leads to the delay in the development

  4. Evaluation of a Peer-Led, Low-Intensity Physical Activity Program for Older Adults

    Science.gov (United States)

    Werner, Danilea; Teufel, James; Brown, Stephen L.

    2014-01-01

    Background: Physical inactivity is a primary contributor to decreasing functional physical fitness and increasing chronic disease in older adults. Purpose: This study assessed the health-related benefits of ExerStart for Lay Leaders, a 20-week, community based, peer-led, low-impact exercise program for older adults. ExerStart focuses on aerobic…

  5. Ultrasound in chemical processes

    International Nuclear Information System (INIS)

    Baig, S.; Farooq, R.; Malik, A.H.

    2009-01-01

    The use of ultrasound to promote chemical reactions or sono chemistry is a field of chemistry which involves the process of acoustic cavitations i.e. the collapse of microscopic bubbles in liquid. There are two essential components for the application of sono chemistry, a liquid medium and a source of high-energy vibrations. The liquid medium is necessary because sono chemistry is driven by acoustic cavitations that can only occur in liquids. The source of the vibrational energy is the transducer. The chemical effects of ultrasound include the enhancement of reaction rates at ambient temperatures and striking advancements in stoichiometric and catalytic reactions In some cases, ultrasonic irradiation can increase reactivities by nearly million fold. The ultrasound has large number of applications not only in emending old chemical processes but also in developing new synthetic strategies. Ultrasound enhances all chemical and physical processes e.g., crystallization, vitamin synthesis, preparation of catalysts, dissolution of chemicals, organometallic reactions, electrochemical processes, etc. High-power ultrasonics is a new powerful technology that is not only safe and environmentally friendly in its application but is also efficient and economical. It can be applied to existing processes to eliminate the need for chemicals and/or heat application in a variety of industrial processes. (author)

  6. Low-intensity interval exercise training attenuates coronary vascular dysfunction and preserves Ca2+-sensitive K+ current in miniature swine with LV hypertrophy

    Science.gov (United States)

    Tharp, Darla L.; Ivey, Jan R.; Ganjam, Venkataseshu K.; Bowles, Douglas K.

    2011-01-01

    Coronary vascular dysfunction has been observed in several models of heart failure (HF). Recent evidence indicates that exercise training is beneficial for patients with HF, but the precise intensity and underlying mechanisms are unknown. Left ventricular (LV) hypertrophy can play a significant role in the development of HF; therefore, the purpose of this study was to assess the effects of low-intensity interval exercise training on coronary vascular function in sedentary (HF) and exercise trained (HF-TR) aortic-banded miniature swine displaying LV hypertrophy. Six months postsurgery, in vivo coronary vascular responses to endothelin-1 (ET-1) and adenosine were measured in the left anterior descending coronary artery. Baseline and maximal coronary vascular conductance were similar between all groups. ET-1-induced reductions in coronary vascular conductance (P < 0.05) were greater in HF vs. sedentary control and HF-TR groups. Pretreatment with the ET type A (ETA) receptor blocker BQ-123 prevented ET-1 hypersensitivity in HF animals. Whole cell voltage clamp was used to characterize composite K+ currents (IK+) in coronary smooth muscle cells. Raising internal Ca2+ from 200 to 500 nM increased Ca2+-sensitive K+ current in HF-TR and control, but not HF animals. In conclusion, an ETA-receptor-mediated hypersensitivity to ET-1, elevated resting LV wall tension, and decreased coronary smooth muscle cell Ca2+-sensitive IK+ was found in sedentary animals with LV hypertrophy. Low-intensity interval exercise training preserved normal coronary vascular function and smooth muscle cell Ca2+-sensitive IK+, illustrating a potential mechanism underlying coronary vascular dysfunction in a large-animal model of LV hypertrophy. Our results demonstrate the potential clinical impact of exercise on coronary vascular function in HF patients displaying pathological LV hypertrophy. PMID:21841018

  7. Low-intensity interval exercise training attenuates coronary vascular dysfunction and preserves Ca²⁺-sensitive K⁺ current in miniature swine with LV hypertrophy.

    Science.gov (United States)

    Emter, Craig A; Tharp, Darla L; Ivey, Jan R; Ganjam, Venkataseshu K; Bowles, Douglas K

    2011-10-01

    Coronary vascular dysfunction has been observed in several models of heart failure (HF). Recent evidence indicates that exercise training is beneficial for patients with HF, but the precise intensity and underlying mechanisms are unknown. Left ventricular (LV) hypertrophy can play a significant role in the development of HF; therefore, the purpose of this study was to assess the effects of low-intensity interval exercise training on coronary vascular function in sedentary (HF) and exercise trained (HF-TR) aortic-banded miniature swine displaying LV hypertrophy. Six months postsurgery, in vivo coronary vascular responses to endothelin-1 (ET-1) and adenosine were measured in the left anterior descending coronary artery. Baseline and maximal coronary vascular conductance were similar between all groups. ET-1-induced reductions in coronary vascular conductance (P < 0.05) were greater in HF vs. sedentary control and HF-TR groups. Pretreatment with the ET type A (ET(A)) receptor blocker BQ-123 prevented ET-1 hypersensitivity in HF animals. Whole cell voltage clamp was used to characterize composite K(+) currents (I(K(+))) in coronary smooth muscle cells. Raising internal Ca(2+) from 200 to 500 nM increased Ca(2+)-sensitive K(+) current in HF-TR and control, but not HF animals. In conclusion, an ET(A)-receptor-mediated hypersensitivity to ET-1, elevated resting LV wall tension, and decreased coronary smooth muscle cell Ca(2+)-sensitive I(K(+)) was found in sedentary animals with LV hypertrophy. Low-intensity interval exercise training preserved normal coronary vascular function and smooth muscle cell Ca(2+)-sensitive I(K(+)), illustrating a potential mechanism underlying coronary vascular dysfunction in a large-animal model of LV hypertrophy. Our results demonstrate the potential clinical impact of exercise on coronary vascular function in HF patients displaying pathological LV hypertrophy.

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page How is the procedure performed? For most ultrasound exams, you will be positioned lying face- ... Ultrasound examinations are painless and easily tolerated by most patients. Ultrasound exams in which the transducer is ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called ... terms of the distance traveled per unit of time, rather than as a color picture. It can ...

  12. Influence of chronic low intensively irradiation on the basic metabolic processes in leguminous plants (fabaceae)

    International Nuclear Information System (INIS)

    Goncharova, N.V.

    2011-01-01

    Effect of the incorporated radionuclides on the basic metabolic processes in leguminous plants growth in inspected conditions was studied. There were findings of the accelerated course of a stage development in ontogenesis, increase of the photosynthetic activity of leaf and peroxidase activity along with a rise of the contents of photosynthetic pigments and lipid peroxidation products. The data are indicative of the distinct stimulation effect induced by the incorporated radionuclides. (authors)

  13. Low-Intensity Vibration as a Treatment for Traumatic Muscle Injury

    Science.gov (United States)

    2017-08-01

    potential for LIV as a non-invasive and simple treatment for improving muscle healing, thereby reducing joint stiffness and increasing mobility of...the LIV signal. If successful, LIV would provide an innovative, non- invasive and simple treatment for improving muscle healing and thereby reducing...were the results disseminated to communities of interest ? Nothing to report What do you plan to do during the next reporting period to accomplish the

  14. The Role of Veterinary Medical Civic Action in the Low Intensity Conflict Environment.

    Science.gov (United States)

    1988-06-03

    increased or improved production of animal food products, insect/ rodent vector control, public health and sanitation, and food sanitation...peaks over 20,000 feet. South America is bounded by these mountains on the west and the 22 Amazon Jungle on the east. Infrastructure development such as...food was too scarce to support the people, let alone the animals. Likewise, a protein supplement program in Peru involving the raising of rabbits was

  15. Preliminary Study of the Effect of Low-Intensity Home-Based Physical Therapy in Chronic Stroke Patients

    Directory of Open Access Journals (Sweden)

    Jau-Hong Lin

    2004-01-01

    Full Text Available This study was a preliminary examination of the effect of low-intensity home-based physical therapy on the performance of activities of daily living (ADL and motor function in patients more than 1 year after stroke. Twenty patients were recruited from a community stroke register in Nan-Tou County, Taiwan, to a randomized, crossover trial comparing intervention by a physical therapist immediately after entry into the trial (Group I or after a delay of 10 weeks (Group II. The intervention consisted of home-based physical therapy once a week for 10 weeks. The Barthel Index (BI and Stroke Rehabilitation Assessment of Movement (STREAM were used as standard measures for ADL and motor function. At the first follow-up assessment at 11 weeks, Group I showed greater improvement in lower limb motor function than Group II. At the second follow-up assessment at 22 weeks, Group II showed improvement while Group I had declined. At 22 weeks, the motor function of upper limbs, mobility, and ADL performance in Group II had improved slightly more than in Group I, but the between-group differences were not significant. It appears that low-intensity home-based physical therapy can improve lower limb motor function in chronic stroke survivors. Further studies will be needed to confirm these findings.

  16. Tumour Cell Membrane Poration and Ablation by Pulsed Low-Intensity Electric Field with Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Lijun Wang

    2015-03-01

    Full Text Available Electroporation is a physical method to increase permeabilization of cell membrane by electrical pulses. Carbon nanotubes (CNTs can potentially act like “lighting rods” or exhibit direct physical force on cell membrane under alternating electromagnetic fields thus reducing the required field strength. A cell poration/ablation system was built for exploring these effects of CNTs in which two-electrode sets were constructed and two perpendicular electric fields could be generated sequentially. By applying this system to breast cancer cells in the presence of multi-walled CNTs (MWCNTs, the effective pulse amplitude was reduced to 50 V/cm (main field/15 V/cm (alignment field at the optimized pulse frequency (5 Hz of 500 pulses. Under these conditions instant cell membrane permeabilization was increased to 38.62%, 2.77-fold higher than that without CNTs. Moreover, we also observed irreversible electroporation occurred under these conditions, such that only 39.23% of the cells were viable 24 h post treatment, in contrast to 87.01% cell viability without presence of CNTs. These results indicate that CNT-enhanced electroporation has the potential for tumour cell ablation by significantly lower electric fields than that in conventional electroporation therapy thus avoiding potential risks associated with the use of high intensity electric pulses.

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3- ...

  19. Low-intensity LED therapy (658 nm) on burn healing: a series of cases.

    Science.gov (United States)

    de Oliveira, Rauirys Alencar; Boson, Luara Lis Barbosa; Portela, Seísa Marina Martins; Filho, Antônio Luiz Martins Maia; de Oliveira Santiago, Denyberg

    2018-05-01

    The objective of this study was to evaluate the effects of LED on burns healing. Five patients with skin burns were submitted to photobiomodulation by LED, GaAsIP diode, (λ 658 nm) with 40 mW, 7 J/cm 2 on every other day. Biopsies of burned skin were performed and the healing process was photographed. Patients with bilateral burns were used as self-control, having one limb being irradiated and the contralateral limb irradiated with placebo. The burns treated with LED showed higher epithelization, with keratinocytes and fibroblasts proliferation, increased collagen synthesis, decreased pain, and pruritus. In conclusion, there was a faster clinical improvement in the irradiated limbs.

  20. Effects of the low-intensity red laser radiation on the fluoride uptake in enamel. A clinical trial; Avaliacao dos efeitos da radiacao laser de emissao vermelha em baixa intensidade na incorporacao de fluor no esmalte. Estudo clinico

    Energy Technology Data Exchange (ETDEWEB)

    Nakasone, Regina Keiko

    2004-07-01

    Fluoride has been the most important preventive method on development of the caries. This in vivo study evaluated the effects of low-intensity red laser radiation on the fluoride uptake in enamel. Ten healthy participants were recruited for this study. The two maxillary central incisors of each volunteer to be biopsied were used and divided into 4 groups: group G{sub C} (control, which was untreated; group G{sub F} (fluoride), which received topical acidulated phosphate fluoride (APF) 1,23% treatment for 4 minutes; group G{sub LF} (laser + fluoride), which was irradiated with a low-intensity diode laser ({lambda}= 660 nm and dose= 6 J/cm{sup 2}) with APF application after irradiation and group G{sub FL} (fluoride + laser), which received APF before irradiation using the same parameters as G{sub LF}. The determination of fluoride was performed using a fluoride ion electrode after an acid-etch enamel biopsy. The results show a significant increase of the fluoride uptake in enamel for groups G{sub F}, G{sub LF} and G{sub FL} when compared to control group. Although a percentage increase of 57% was observed for G{sub LF} with respect to G{sub F}, there were no statistical differences among treated groups. These findings suggest that low-intensity laser radiation used before APF could be employed in the clinical practice to prevent dental caries. (author)

  1. Evaluation of low intensity laser effects in the thyroid glands region of male mice

    International Nuclear Information System (INIS)

    Azevedo, Luciane Hiramatsu

    2002-01-01

    Recent studies have demonstrated that the infra-red laser can cause alterations in thyroid glands. Their normal activity must be preserved, as they produce the thyroidal hormones triiodothyronine (T 3 ) and thyroxine (T 4 ), that stimulate the oxidative metabolism, essential to maintain a healthy organism. The increase or diminution of these hormones results in alteration of the mitochondria's activity, that determines the secondary effects in the metabolism. The purpose of this study was to evaluate if there was any alteration of the thyroidal hormones plasma levels under irradiation from infra-red laser, with energy density of 4J/cm 2 , in the region of thyroid glands of male mice. It was concluded that there was an hormonal level alteration statistically significant between the first day of irradiation and seven days after the last application. Histological studies showed that there was no morphological changes in histological sections of thyroid glands. The optical absorption spectroscopy of mice's serum presented a peak at approximately 280 nm, attributed to tyrosine (this is the amino acid compounding these hormones). (author)

  2. The Fight for Oman 1963-1975 Analysis of Civil-Military Operations in Low-Intensity Conflict and its Relevance to Current World Conflict

    National Research Council Canada - National Science Library

    Sarnoski, Robert

    1995-01-01

    .... While often overlooked, the government response to the 1963-1975 insurgency in Oman provides excellent examples of both ineffective and effective national-military strategies for combating a low intensity threat...

  3. Individual common carotid artery wall layer dimensions, but not carotid intima-media thickness, indicate increased cardiovascular risk in women with preeclampsia: an investigation using noninvasive high-frequency ultrasound.

    Science.gov (United States)

    Akhter, Tansim; Wikström, Anna-Karin; Larsson, Marita; Naessen, Tord

    2013-09-01

    Preeclampsia (PE) is associated with increased risk of cardiovascular disease later in life. Ultrasound assessment of the common carotid artery intima-media thickness (IMT) during or after PE has not indicated any increased cardiovascular risk. We used high-frequency ultrasound (22 MHz) to estimate the individual common carotid artery IMTs in 55 women at PE diagnosis and in 64 women with normal pregnancies at a similar stage. All were re-examined about 1 year postpartum. A thick intima, thin media, and high intima/media (I/M) ratio are signs of a less healthy artery wall. PE was associated with a significantly thicker mean common carotid artery intima, thinner media, and higher I/M ratio than in normal pregnancy (mean I/M difference, 0.21; 95% confidence interval, 0.17-0.25; Pwomen with PE were negatively affected during pregnancy and 1 year postpartum compared with women with normal pregnancies, indicating increased cardiovascular risk. Estimation of intima thickness and I/M ratio seem preferable to estimation of common carotid artery IMT in imaging cardiovascular risk in PE. Results from this pilot study warrant further confirmation.

  4. [Effect of low-intensity electromagnetic fields of industrial frequency on the ultrastructure and proliferative activity of rat's thymus cells].

    Science.gov (United States)

    Zhitkevich, T I; Bokut', T B; Netukova, N I

    2001-01-01

    Effects of two types of low-intensity electromagnetic fields (EMF) of industrial frequency (50 Hz) on the fine structure and proliferative activity of thymic cells in white rats were studied. It was found that a weak EMF with a prevailing electrical component (380-480 V/m, 120-140 nT1) did not affect the DNA synthesis intensity. An EMF with a stronger magnetic induction (10-15 V/m, 800-1500 nT1) diminished the glucose-6-phosphate dehydrogenase activity and proliferative processes in cultured stimulated lymphocytes. Electron microscopic investigation of the thymus after both types of exposure revealed an accumulation of lymphocytes with pyknotic nuclei and electron-dense cytoplasm, as well as hypoplasia of the vascular endothelium. At the same time, EMF with a prevailing magnetic component produced a more marked negative effect on the ultrastructure of thymic cells, which indicated a lowered secretory activity of epitheliocytes.

  5. In Situ Irradiation and Measurement of Triple Junction Solar Cells at Low Intensity, Low Temperature (LILT) Conditions

    Science.gov (United States)

    Harris, R.D.; Imaizumi, M.; Walters, R.J.; Lorentzen, J.R.; Messenger, S.R.; Tischler, J.G.; Ohshima, T.; Sato, S.; Sharps, P.R.; Fatemi, N.S.

    2008-01-01

    The performance of triple junction InGaP/(In)GaAs/Ge space solar cells was studied following high energy electron irradiation at low temperature. Cell characterization was carried out in situ at the irradiation temperature while using low intensity illumination, and, as such, these conditions reflect those found for deep space, solar powered missions that are far from the sun. Cell characterization consisted of I-V measurements and quantum efficiency measurements. The low temperature irradiations caused substantial degradation that differs in some ways from that seen after room temperature irradiations. The short circuit current degrades more at low temperature while the open circuit voltage degrades more at room temperature. A room temperature anneal after the low temperature irradiation produced a substantial recovery in the degradation. Following irradiation at both temperatures and an extended room temperature anneal, quantum efficiency measurement suggests that the bulk of the remaining damage is in the (In)GaAs sub-cell

  6. Can Energy Cost During Low-Intensity Resistance Exercise be Predicted by the OMNI-RES Scale?

    Science.gov (United States)

    Vianna, Jefferson M.; Reis, Victor M.; Saavedra, Francisco; Damasceno, Vinicius; Silva, Sérgio G.; Goss, Fredric

    2011-01-01

    The aim of the present study was to assess the precision of the OMNI-RES scale to predict energy cost (EC) at low intensity in four resistance exercises (RE). 17 male recreational body builders (age = 26.6 ± 4.9 years; height = 177.7 ± 0.1 cm; body weight = 79.0 ± 11.1 kg and percent body fat = 10.5 ± 4.6%) served as subjects. Initially tests to determine 1RM for four resistance exercises (bench press, half squat, lat pull down and triceps extension) were administered. Subjects also performed resistance exercise at 12, 16, 20, and 24% of 1RM at a rate of 40 bpm until volitional exhaustion. Oxygen uptake (VO2) and rate of perceived exertion (RPE) using the OMNI-RES were obtained during and after all RE. EC was calculated using VO2 and the caloric values of VO2 for non-protein RER. Regression analyses were performed for every RE, using EC as the dependent and RPE as the predictor variable. The triceps extension, lat pull down and bench press, RPE correlated strongly with EC (R > 0.97) and predicted EC with a error of less than 0.2 kcal.min−1. In conclusion, RPE using the OMNI-RES scale can be considered as an accurate indicator of EC in the bench press, lat pull down and triceps extension performed by recreational bodybuilders, provided lower intensities are used (up to 24% of 1-RM) and provided each set of exercise is performed for the maximal sustainable duration. It would be interesting in future studies to consider having the subjects exercise at low intensities for longer durations than those in the present study. PMID:23486188

  7. Importance of ventricular rate after mode switching during low intensity exercise as assessed by clinical symptoms and ventilatory gas exchange.

    Science.gov (United States)

    Brunner-La Rocca, H P; Rickli, H; Weilenmann, D; Duru, F; Candinas, R

    2000-01-01

    Automatic mode switching from DDD(R) to DDI(R) or VVI(R) pacing modes has improved dual chamber pacing in patients at high risk for supraventricular tachyarrhythmias. However, little is known about the effect of ventricular pacing rate adaptation after mode switching. We conducted a single-blinded, crossover study in 15 patients (58 +/- 21 years) with a DDD pacemaker who had AV block and normal sinus node function to investigate the influence of pacing rate adaptation to intrinsic heart rate during low intensity exercise. Patients performed two tests (A/B) of low intensity treadmill exercise (0.5 W/kg) in randomized order. They initially walked for 6 minutes while paced in DDD mode. The pacing mode was then switched to VVI with a pacing rate of either 70 beats/min (test A) or matched to the intrinsic heart rate (95 +/- 11 beats/min test B). Respiratory gas exchange variables were determined and patients classified the effort before and after mode switching on a Borg scale from 6 to 20. Percentage changes of respiratory gas exchange measurements were significantly larger (O2 consumption: -8.2 +/- 5.0% vs. -0.6 +/- 7.2%; ventilatory equivalent of CO2 exhalation: 5.3 +/- 4.9% vs. 1.5 +/- 4.3%; respiratory exchange ratio: 7.0 +/- 2.2% vs. 3.5 +/- 3.0%; end-tidal CO2: -5.7 +/- 2.9% vs. -1.8 +/- 2.7%; all P rate unadjusted than after adjusted mode switching. Mode switching from DDD to VVI pacing is better tolerated and gas exchange measurements are less influenced if ventricular pacing rate is adjusted to the level of physical activity. Thus, pacing rate adjustment should be considered as part of automatic mode switch algorithms.

  8. Efficacy and Safety of Uninterrupted Low-Intensity Warfarin for Radiofrequency Catheter Ablation of Atrial Fibrillation in the Elderly.

    Science.gov (United States)

    Xing, Yangbo; Xu, Buyun; Xu, Chao; Peng, Fang; Yang, Biao; Qiu, Yufang; Sun, Yong; Wang, Shengkai; Guo, Hangyuan

    2017-09-01

    No previous studies exist investigating the optimal intensity of uninterrupted anticoagulation with warfarin during radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) in the elderly. Evaluate the efficacy and safety of continuous low-intensity warfarin therapy throughout the periprocedural period of RFCA for AF in the elderly. This is a prospective randomized study. We enrolled AF patients (age ≥ 70 years) who underwent first-time RFCA for AF. Enrolled patients were randomized to group A and group B. The international normalized ratios before ablation were maintained at 1.5 to 2.0 and 2.0 to 2.5 in group A and B, respectively. Primary end points were periprocedural thromboembolic complications and major bleeding. Secondary end points included periprocedural asymptomatic cerebral emboli (ACE) and minor bleeding. A total of 101 patients were enrolled in our study (group A: 52; group B: 49). Baseline characteristics were well balanced between the 2 groups. Only 1 patient suffered from stroke in group B. No major bleeding events occurred in either group. The incidence of new ACE lesions was comparable between the 2 groups (11.5% vs 8.2%, P = 0.82). Minor bleeding occurred in 1 of 52 (1.9%) patients in group A and in 5 of 49 (10.2%) patients in group B ( P = 0.10). Uninterrupted low-intensity warfarin for RFCA of AF might be as effective as standard-intensity warfarin in preventing periprocedural thromboembolic complications and might be associated with fewer bleeding events in the elderly.

  9. Effects of the low-intensity laser therapy on the prevention of dental caries induced in rats

    International Nuclear Information System (INIS)

    Mueller, Karin Praia

    2004-01-01

    The purpose of this study was to investigate the effects of low intensity laser therapy, associated or not to an acidulated phosphate fluoride, on the prevention of dental caries induced in rats. It was used 40 wistar rats, female, weaned with 18 days, fed with a cariogenic diet during 48 days and inoculated orally with Streptococcus mutans by three consecutive days starting from the second day of the diet. On the fifth day of experiment the animals were divided into five groups: G c (control) the animas were no submitted to any treatment; G L (laser) irradiation with low power laser (GaAlAs, λ=660 nm, P=30 mW, Δt=5 sec, 5 J/cm 2 ); G F (fluoride) topical application of acidulated phosphate fluoride (APF 1,23%) for four minutes; G LF (laser + fluoride) irradiation with low power laser followed by topical application of acidulated phosphate fluoride; G FL (fluoride + laser) topical application of acidulated phosphate fluoride followed by low power laser. The animals were sacrificed after 48 days; the molars were extracted and prepared to determine the dental caries lesions area by optical microscopy, enamel microhardness and analysis of the calcium and phosphorus ratio (Ca/P) by energy dispersive spectroscopy. The results were statistically analyzed by ANOVA (p LF was smaller than that for G F and G FL groups but no statistical difference was observed. There was no significant statistical difference between the microhardness of the G C and G L groups and among G FL , G LF and G F groups. Regarding to the calcium and phosphorus ratio, it was not observed significant statistical differences among the groups. These findings suggest that low-intensity laser radiation associated with acidulated phosphate fluoride reduces the caries area and could be an alternative in the prevention of the dental caries. (author)

  10. The principles of ultrasound and its application in freezing related processes of food materials: A review.

    Science.gov (United States)

    Cheng, Xinfeng; Zhang, Min; Xu, Baoguo; Adhikari, Benu; Sun, Jincai

    2015-11-01

    Ultrasonic processing is a novel and promising technology in food industry. The propagation of ultrasound in a medium generates various physical and chemical effects and these effects have been harnessed to improve the efficiency of various food processing operations. Ultrasound has also been used in food quality control as diagnostic technology. This article provides an overview of recent developments related to the application of ultrasound in low temperature and closely related processes such as freezing, thawing, freeze concentration and freeze drying. The applications of high intensity ultrasound to improve the efficiency of freezing process, to control the size and size distribution of ice crystals and to improve the quality of frozen foods have been discussed in considerable detail. The use of low intensity ultrasound in monitoring the ice content and to monitor the progress of freezing process has also been highlighted. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Estimation of Tumor Angiogenesis With Contrast Enhanced Subharmonic Ultrasound Imaging

    National Research Council Canada - National Science Library

    Forsberg, Flemming

    2005-01-01

    ...) and receiving at the subharmonic (f0). Hence, the current project proposes to increase the ability of breast ultrasound to differentiate between benign and malignant lesions by combining injection of an ultrasound contrast agent with SHI...

  12. Estimation of Tumor Angiogenesis With Contrast Enhanced Subharmonic Ultrasound Imaging

    National Research Council Canada - National Science Library

    Forsberg, Flemming

    2002-01-01

    .... Hence, the current project proposes to increase the ability of breast ultrasound to differentiate between benign and malignant lesions by combining injection of an ultrasound contrast agent with SHI...

  13. Estimation of Tumor Angiogenesis with Contrast Enhanced Subharmonic Ultrasound Imaging

    National Research Council Canada - National Science Library

    Forsberg, Flemming

    2004-01-01

    .... Hence, the current project proposes to increase the ability of breast ultrasound to differentiate between benign and malignant lesions by combining injection of an ultrasound contrast agent with SHI...

  14. Estimation of Tumor Angiogenesis With Constrast Enhanced Subharmonic Ultrasound Imaging

    National Research Council Canada - National Science Library

    Forsberg, Fleming

    2003-01-01

    .... Hence, the current project proposes to increase the ability of breast ultrasound to differentiate between denign and malignant lesions by combining injection of an ultrasound contrast agent with SHI...

  15. Changes in Antioxidant Defense Capability and Lipid Profile after 12-Week Low- Intensity Continuous Training in Both Cigarette and Hookah Smokers: A Follow-Up Study

    Science.gov (United States)

    Koubaa, Abdessalem; Triki, Moez; Trabelsi, Hajer; Masmoudi, Liwa; Sahnoun, Zouhair; Hakim, Ahmed

    2015-01-01

    To examine the impact of low-intensity continuous training program on antioxidant defense capability and lipid profile in male cigarette or hookah smokers. Forty-three male adults participated in a 12-week continuous training program at an intensity of 40% of VO2max. All subjects were subjected to anthropometric, physical and biochemical tests before and after the training program. The increase of Glutathione reductase (GR) and Superoxide dismutase (SOD) is significant only for cigarette smokers (CS) and hookah smokers (HS) groups. The Malondialdehyde (MDA) decrease and α-tocopherol increase are significant only for HS group. GPx was increased in NS, CS and HS by 2.6% (p< 0.01), 2% (p< 0.05) and 1.7% (p< 0.05) respectively. Likewise, significant improvements of high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C) and TC / HDL-C ratio were observed in three groups. En contrast no significant changes were recorded in triglycerides (TG). Also, significant reduction of total cholesterol (TC) for CS group (p< 0.01) and HS groups (p< 0.05). This continuous training program appears to have an important role in lipid levels improving and oxidative stress attenuation. PMID:26121249

  16. Enhancement or Reduction of Sonochemical Activity of Pulsed Ultrasound Compared to Continuous Ultrasound at 20 kHz?

    Directory of Open Access Journals (Sweden)

    Yujing Sun

    2013-04-01

    Full Text Available Little is known about the efficacy of pulsed ultrasound compared with continuous ultrasound. Previous studies on the efficacy of pulsed ultrasound were not systematic and gave different results. In this study, the effects of pulse length, pulse interval, pulse length × pulse intervals, and treatment time on sonochemical activity were investigated using a simple oxidation of iodide method and a comparison of the efficacy of pulsed ultrasound and continuous ultrasound is made. The results showed that the main factor in the efficacy of pulsed ultrasound was pulse length when pulse length varied from 0.1 to 1 s. However, the main factors were pulse length, the pulse length × pulse interval, and pulse interval when pulse length varied from 1 to 9 s. Pulsed ultrasound had no effect when the pulse length was 0.1 s; however, the sonochemical activity of pulsed ultrasound decreased compared to continuous ultrasound as the pulse length varied from 0.1 to 1 s. The sonochemical activity of pulsed ultrasound either increased or decreased compared to continuous ultrasound when pulse length varied from 1 to 9 s, but the increase or decrease had no clear trend. The sonochemical activity was constant at Ton/Toff = 2 s/2 s and slightly decreased at Ton/Toff = 3 s/2 s with time, whereas the sonochemical activity of continuous ultrasound significantly decreased with time. Enhancement or reduction of sonochemical activity of pulsed ultrasound compared to continuous ultrasound depended on the pulse length and pulse interval.

  17. Sensitivity of simulated transcranial ultrasound fields to acoustic medium property maps

    Science.gov (United States)

    Robertson, James; Martin, Eleanor; Cox, Ben; Treeby, Bradley E.

    2017-04-01

    High intensity transcranial focused ultrasound is an FDA approved treatment for essential tremor, while low-intensity applications such as neurostimulation and opening the blood brain barrier are under active research. Simulations of transcranial ultrasound propagation are used both for focusing through the skull, and predicting intracranial fields. Maps of the skull acoustic properties are necessary for accurate simulations, and can be derived from medical images using a variety of methods. The skull maps range from segmented, homogeneous models, to fully heterogeneous models derived from medical image intensity. In the present work, the impact of uncertainties in the skull properties is examined using a model of transcranial propagation from a single element focused transducer. The impact of changes in bone layer geometry and the sound speed, density, and acoustic absorption values is quantified through a numerical sensitivity analysis. Sound speed is shown to be the most influential acoustic property, and must be defined with less than 4% error to obtain acceptable accuracy in simulated focus pressure, position, and volume. Changes in the skull thickness of as little as 0.1 mm can cause an error in peak intracranial pressure of greater than 5%, while smoothing with a 1 \\text{m}{{\\text{m}}3} kernel to imitate the effect of obtaining skull maps from low resolution images causes an increase of over 50% in peak pressure. The numerical results are confirmed experimentally through comparison with sonications made through 3D printed and resin cast skull bone phantoms.

  18. Ultrasound in Space Medicine

    Science.gov (United States)

    Dulchavsky, Scott A.; Sargsyan, A.E.

    2009-01-01

    This slide presentation reviews the use of ultrasound as a diagnostic tool in microgravity environments. The goals of research in ultrasound usage in space environments are: (1) Determine accuracy of ultrasound in novel clinical conditions. (2) Determine optimal training methodologies, (3) Determine microgravity associated changes and (4) Develop intuitive ultrasound catalog to enhance autonomous medical care. Also uses of Ultrasound technology in terrestrial applications are reviewed.

  19. Effect of Linear Low-Intensity Extracorporeal Shockwave Therapy for Erectile Dysfunction-12-Month Follow-Up of a Randomized, Double-Blinded, Sham-Controlled Study.

    Science.gov (United States)

    Fojecki, Grzegorz Lukasz; Tiessen, Stefan; Osther, Palle Jørn Sloth

    2018-03-01

    Short-term data on the effect of low-intensity extracorporeal shockwave therapy (Li-ESWT) on erectile dysfunction (ED) have been inconsistent. The suggested mechanisms of action of Li-ESWT on ED include stimulation of cell proliferation, tissue regeneration, and angiogenesis, which can be processes with a long generation time. Therefore, long-term data on the effect of Li-ESWT on ED are strongly warranted. To assess the outcome at 6 and 12 months of linear Li-ESWT on ED from a previously published randomized, double-blinded, sham-controlled trial. Subjects with ED (N = 126) who scored lower than 25 points in the erectile function domain of the International Index of Erectile Function (IIEF-EF) were eligible for the study. They were allocated to 1 of 2 groups: 5 weekly sessions of sham treatment (group A) or linear Li-ESWT (group B). After a 4-week break, the 2 groups received active treatment once a week for 5 weeks. At baseline and 6 and 12 months, subjects were evaluated by the IIEF-EF, the Erectile Hardness Scale (EHS), and the Sexual Quality of Life in Men. The primary outcome measure was an increase of at least 5 points in the IIEF-EF (ΔIIEF-EF score). The secondary outcome measure was an increase in the EHS score to at least 3 in men with a score no higher than 2 at baseline. Data were analyzed by linear and logistic regressions. Linear regression of the ΔIIEF-EF score from baseline to 12 months included 95 patients (dropout rate = 25%). Adjusted for the IIEF-EF score at baseline, the difference between groups B and A was -1.30 (95% CI = -4.37 to 1.77, P = .4). The success rate based on the main outcome parameter (ΔIIEF-EF score ≥ 5) was 54% in group A vs 47% in group B (odds ratio = 0.67, P = .28). Improvement based on changes in the EHS score in groups A and B was 34% and 24%, respectively (odds ratio = 0.47, P = .82). Exposure to 2 cycles of linear Li-ESWT for ED is not superior to 1 cycle at 6- and 12-month follow-ups. Fojecki GL, Tiessen S

  20. Correspondence optimization in 2D standardized carotid wall thickness map by description length minimization: A tool for increasing reproducibility of 3D ultrasound-based measurements.

    Science.gov (United States)

    Chen, Yimin; Chiu, Bernard

    2016-12-01

    The previously described 2D standardized vessel-wall-plus-plaque thickness (VWT) maps constructed from 3D ultrasound vessel wall measurements using an arc-length (AL) scaling approach adjusted the geometric variability of carotid arteries and has allowed for the comparisons of VWT distributions in longitudinal and cross-sectional studies. However, this mapping technique did not optimize point correspondence of the carotid arteries investigated. The potential misalignment may lead to errors in point-wise VWT comparisons. In this paper, we developed and validated an algorithm based on steepest description length (DL) descent to optimize the point correspondence implied by the 2D VWT maps. The previously described AL approach was applied to obtain initial 2D maps for a group of carotid arteries. The 2D maps were reparameterized based on an iterative steepest DL descent approach, which consists of the following two steps. First, landmarks established by resampling the 2D maps were aligned using the Procrustes algorithm. Then, the gradient of the DL with respect to horizontal and vertical reparameterizations of each landmark on the 2D maps was computed, and the 2D maps were subsequently deformed in the direction of the steepest descent of DL. These two steps were repeated until convergence. The quality of the correspondence was evaluated in a phantom study and an in vivo study involving ten carotid arteries enrolled in a 3D ultrasound interscan variability study. The correspondence quality was evaluated in terms of the compactness and generalization ability of the statistical shape model built based on the established point correspondence in both studies. In the in vivo study, the effect of the proposed algorithm on interscan variability of VWT measurements was evaluated by comparing the percentage of landmarks with statistically significant VWT-change before and after point correspondence optimization. The statistical shape model constructed with optimized

  1. Point-of-Care Ultrasound: A Trend in Health Care.

    Science.gov (United States)

    Buerger, Anita M; Clark, Kevin R

    2017-11-01

    To discuss the current and growing use of point-of-care (POC) ultrasound in the management and care of patients. Several electronic research databases were searched to find articles that emphasized the use of POC ultrasound by health care providers who manage and treat critically ill or injured patients. Thirty-five relevant peer-reviewed journal articles were selected for this literature review. Common themes identified in the literature included the use of POC ultrasound in emergency medicine, military medicine, and remote care; comparison of POC ultrasound to other medical imaging modalities; investigation of the education and training required for nonimaging health care professionals who perform POC ultrasound in their practices; and discussion of the financial implications and limitations of POC ultrasound. POC ultrasound provides clinicians with real-time information to better manage and treat critically ill or injured patients in emergency medicine, military medicine, and remote care. In addition to providing immediate bedside diagnostic information, use of POC ultrasound has increased because of concerns regarding radiation protection. Finally, the expansion of POC ultrasound to other specialty areas requires nonimaging health care professionals to perform bedside ultrasound examinations and interpret the resulting images. Because POC ultrasound is user-dependent, adequate training is essential for all who perform and interpret the examinations. Research involving POC ultrasound will continue as innovations and confidence in ultrasound applications advance. Future research should continue to examine the broad use of POC ultrasound in patient care and management. ©2017 American Society of Radiologic Technologists.

  2. Increased carotid intima thickness and decreased media thickness in premenopausal women with systemic lupus erythematosus: an investigation by non-invasive high-frequency ultrasound.

    Science.gov (United States)

    Leonard, D; Akhter, T; Nordmark, G; Rönnblom, L; Naessen, T

    2011-01-01

    To determine whether high-frequency ultrasound (US) yielding separate assessments of intima and media thickness gives additional information about the vascular morphology compared with the total common carotid artery intima-media thickness (CCA-IMT). Using a 22 MHz US instrument, we determined the near-wall CCA-IMT, the intima and media layers, and the intima/media (I/M) ratio in 47 premenopausal women with systemic lupus erythematosus (SLE), 20 healthy women, and 17 postmenopausal women (mean ages 37, 40, and 69 years, respectively). In SLE, the carotid intima was thicker (0.19 ± 0.04 vs. 0.12 ± 0.02 mm), the media thinner (0.45 ± 0.12 vs. 0.68 ± 0.24 mm), the I/M ratio higher (0.45 ± 0.17 vs. 0.20 ± 0.07) (all p women (0.19 ± 0.04 vs. 0.14 ± 0.03 mm, p media, and a higher I/M ratio in women with SLE compared to healthy controls and indicated an artery wall status in SLE comparable to 30-years-older healthy women. Separate estimates of carotid intima and media layers may be preferable to CCA-IMT in SLE patients.

  3. Safety of Medical Diagnostic Ultrasound

    International Nuclear Information System (INIS)

    Breyer, B.

    1998-01-01

    Large numbers of people (both sick and healthy) are routinely exposed to ultrasound waves. We shall discuss wave parameters and scanner properties that are relevant to the safety aspect. This includes central pulse frequency, pulse length, intensity (ISPTA and others), focusing, pulse repetition frequency, pulse pressure, etc. Since the transmitted ultrasound power has steadily been increasing during the last two decades, the problems are becoming more serious with time. Doppler methods have gained importance and 'popularity, which additionally increases ultrasound power requirements since the reflectivity of red blood cells is so small that the backscattered pressure is about 100 times less than that from soft tissue structures in the body. Main mechanisms that can potentially present hazard are heating and cavitation. The basic parameter used to assess thermal hazard is ISPTA and the optimal predictor of cavitation hazard is the peak rarefractional pressure. The hazard of heating-up can be summarized in saying that temperatures up to 38.5 o C are safe, while temperatures above 41 o C are definitely not. Care must be taken to stay within the safe zone. However, there does not exist a confirmed report of any type of hazardous effects on humans using intensities presently applied in diagnostic ultrasound scanners. Taking this into account, various international bodies have put limits to the application of ultrasound, which is best summarized in the FDA (USA) regulation that diagnostic apparatus may have an output of maximally 720 mW/cm 2 (derated) provided thermal and mechanical properties are indicated (onscreen) by properly defined Thermal Indices (TI) and Mechanical Index (MI). These aspects shall be discussed in some detail. We shall give the rules for the operator to apply ultrasound with minimal hazard. The general conclusion is that diagnostic ultrasound, as presently known, may be used whenever a qualified expert expects essential medical benefit for the

  4. Decision Making with Ultrasound in Rheumatology

    NARCIS (Netherlands)

    M. van der Ven (Myrthe)

    2018-01-01

    markdownabstractThe _first aim_ of this thesis was to evaluate the added value of ultrasound in clinical decision making in patients with arthralgia, patients with psoriasis and monitoring RA patients. Our _second aim_ was to increase sensitivity of power Doppler ultrasound for MCP joints.

  5. Ultrasound contrast-agent improves imaging of lower limb occlusive disease

    DEFF Research Database (Denmark)

    Eiberg, J P; Hansen, M A; Jensen, F

    2003-01-01

    to evaluate if ultrasound contrast-agent infusion could improve duplex-ultrasound imaging of peripheral arterial disease (PAD) and increase the agreement with digital subtraction arteriography (DSA).......to evaluate if ultrasound contrast-agent infusion could improve duplex-ultrasound imaging of peripheral arterial disease (PAD) and increase the agreement with digital subtraction arteriography (DSA)....

  6. Impact on the Quality of Erections after Completing a Low-Intensity Extracorporeal Shock Wave Treatment Cycle on a Group of 710 Patients

    Directory of Open Access Journals (Sweden)

    Héctor A. Corredor Ayala

    2017-01-01

    Full Text Available Objective. The aim of this study is to evaluate the response to low-intensity extracorporeal shock wave therapy in a group of patients with organic vascular erectile dysfunction. Materials and Methods. This is an observational retrospective study. The researchers reviewed 710 patients with a clinical diagnosis of organic vascular erectile dysfunction (ED of more than 3-month duration from male sexual health clinics of the Boston Medical Group from 12 cities in Spain and 4 in Mexico. Patients received 5 outpatient shock wave therapy sessions. They were evaluated with the erection hardness score (EHS before the first session (n = 710, at the end of the last session (n = 710, and one month after the last session (n = 412. Results. In the first examination, the EHS improved in 43.1% (306/710 of subjects compared to the baseline measurement and ability to penetrate increased from 26.8% to 44% (p<0.0001. In the second examination, the ability to penetrate was 37.9%, lower than in the first (p=0.042 but higher than the baseline (p=0.0001. Conclusions. The results suggest that the shock wave therapy with or without concomitant treatments improved the quality of erections in patients with erectile dysfunction treated in specialised male sexual health clinics. This trial is registered with NCT03237143.

  7. Effect of Linear Low-Intensity Extracorporeal Shockwave Therapy for Erectile Dysfunction-12-Month Follow-Up of a Randomized, Double-Blinded, Sham-Controlled Study

    DEFF Research Database (Denmark)

    Fojecki, Grzegorz Lukasz; Tiessen, Stefan; Sloth Osther, Palle Jørn

    2018-01-01

    -EF (ΔIIEF-EF score). The secondary outcome measure was an increase in the EHS score to at least 3 in men with a score no higher than 2 at baseline. Data were analyzed by linear and logistic regressions. RESULTS: Linear regression of the ΔIIEF-EF score from baseline to 12 months included 95 patients (dropout......INTRODUCTION: Short-term data on the effect of low-intensity extracorporeal shockwave therapy (Li-ESWT) on erectile dysfunction (ED) have been inconsistent. The suggested mechanisms of action of Li-ESWT on ED include stimulation of cell proliferation, tissue regeneration, and angiogenesis, which...... can be processes with a long generation time. Therefore, long-term data on the effect of Li-ESWT on ED are strongly warranted. AIM: To assess the outcome at 6 and 12 months of linear Li-ESWT on ED from a previously published randomized, double-blinded, sham-controlled trial. METHODS: Subjects with ED...

  8. Reactive oxygen species levels and DNA fragmentation on astrocytes in primary culture after acute exposure to low intensity microwave electromagnetic field.

    Science.gov (United States)

    Campisi, Agata; Gulino, Marisa; Acquaviva, Rosaria; Bellia, Paolo; Raciti, Giuseppina; Grasso, Rosaria; Musumeci, Francesco; Vanella, Angelo; Triglia, Antonio

    2010-03-31

    The exposure of primary rat neocortical astroglial cell cultures to acute electromagnetic fields (EMF) in the microwave range was studied. Differentiated astroglial cell cultures at 14 days in vitro were exposed for 5, 10, or 20min to either 900MHz continuous waves or 900MHz waves modulated in amplitude at 50Hz using a sinusoidal waveform and 100% modulation index. The strength of the electric field (rms value) at the sample position was 10V/m. No change in cellular viability evaluated by MTT test and lactate dehydrogenase release was observed. A significant increase in ROS levels and DNA fragmentation was found only after exposure of the astrocytes to modulated EMF for 20min. No evident effects were detected when shorter time intervals or continuous waves were used. The irradiation conditions allowed the exclusion of any possible thermal effect. Our data demonstrate, for the first time, that even acute exposure to low intensity EMF induces ROS production and DNA fragmentation in astrocytes in primary cultures, which also represent the principal target of modulated EMF. Our findings also suggest the hypothesis that the effects could be due to hyperstimulation of the glutamate receptors, which play a crucial role in acute and chronic brain damage. Furthermore, the results show the importance of the amplitude modulation in the interaction between EMF and neocortical astrocytes. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  9. Cellular and genetic effects and recovery of heat-damaged cells of Saccharomyces cerevisiae by low intensity electromagnetic radiation at 915 MHz

    International Nuclear Information System (INIS)

    Sheikh, I.H.

    1984-01-01

    Studies were conducted on two genetically well known strains of Saccharomyces cerevisiae (Wild Type) and repair deficient mutant (UVS). Results obtained showed clear genetic difference between normal and mutants based on UV sensitivity, percent survival at elevated temperatures and high intensity electromagnetic radiation. At the cellular level, both strains showed a consistent increase in the recovery rate of heat damaged cells when exposed to low intensity FMR as compared to sham (non irradiated cells) at 915 MHz. The percent recovery of wild type was higher than mutant. At the molecular level, the uptake of tritiated uridine into thermally damaged cells which were recovered by low level EMR was significantly higher than sham. Total RNA isolated from irradiated cells and sham showed visible differences in the intensity of RNA bands. Gross quantitative analyses suggest more RNA production in radiation recovered cells as compared to sham. Results presented in this dissertation provide conclusive evidence that low level microwave radiation can be used in the recovery of heat damaged cells

  10. Improvement of localised corrosion resistance of AISI 2205 Duplex Stainless Steel joints made by gas metal arc welding under electromagnetic interaction of low intensity

    Energy Technology Data Exchange (ETDEWEB)

    García-Rentería, M.A., E-mail: crazyfim@gmail.com [Instituto de Investigación en Metalurgia y Materiales, Universidad Michoacana de San Nicolás de Hidalgo, A.P. 888, CP 58000, Morelia, Michoacán (Mexico); López-Morelos, V.H., E-mail: vhlopez@umich.mx [Instituto de Investigación en Metalurgia y Materiales, Universidad Michoacana de San Nicolás de Hidalgo, A.P. 888, CP 58000, Morelia, Michoacán (Mexico); García-Hernández, R., E-mail: rgarcia@umich.mx [Instituto de Investigación en Metalurgia y Materiales, Universidad Michoacana de San Nicolás de Hidalgo, A.P. 888, CP 58000, Morelia, Michoacán (Mexico); Dzib-Pérez, L., E-mail: luirdzib@uacam.mx [Centre for Corrosion Research, Autonomous University of Campeche, Av. Agustín Melgar s/n, Col. Buenavista, CP 24039, Campeche, Cam (Mexico); García-Ochoa, E.M., E-mail: emgarcia@uacam.mx [Centre for Corrosion Research, Autonomous University of Campeche, Av. Agustín Melgar s/n, Col. Buenavista, CP 24039, Campeche, Cam (Mexico); González-Sánchez, J., E-mail: jagonzal@uacam.mx [Centre for Corrosion Research, Autonomous University of Campeche, Av. Agustín Melgar s/n, Col. Buenavista, CP 24039, Campeche, Cam (Mexico)

    2014-12-01

    Highlights: • Electromagnetic interaction in welding improved localised corrosion resistance. • Electromagnetic interaction in welding enhanced γ/δ phase balance of DuplexSS. • Welding under Electromagnetic interaction repress formation and growth of detrimental phases. • Welds made with gas protection (2% O{sub 2} + 98% Ar) have better microstructural evolution during welding. - Abstract: The resistance to localised corrosion of AISI 2205 duplex stainless steel plates joined by Gas Metal Arc Welding (GMAW) under the effect of electromagnetic interaction of low intensity (EMILI) was evaluated with sensitive electrochemical methods. Welds were made using two shielding gas mixtures: 98% Ar + 2% O{sub 2} (M1) and 97% Ar + 3% N{sub 2} (M2). Plates were welded under EMILI using the M1 gas with constant welding parameters. The modified microstructural evolution in the high temperature heat affected zone and at the fusion zone induced by application of EMILI during welding is associated with the increase of resistance to localised corrosion of the welded joints. Joints made by GMAW using the shielding gas M2 without the application of magnetic field presented high resistance to general corrosion but high susceptibility to undergo localised attack.

  11. Low-intensity cognitive-behaviour therapy interventions for obsessive-compulsive disorder compared to waiting list for therapist-led cognitive-behaviour therapy: 3-arm randomised controlled trial of clinical effectiveness.

    Directory of Open Access Journals (Sweden)

    Karina Lovell

    2017-06-01

    Full Text Available Obsessive-compulsive disorder (OCD is prevalent and without adequate treatment usually follows a chronic course. "High-intensity" cognitive-behaviour therapy (CBT from a specialist therapist is current "best practice." However, access is difficult because of limited numbers of therapists and because of the disabling effects of OCD symptoms. There is a potential role for "low-intensity" interventions as part of a stepped care model. Low-intensity interventions (written or web-based materials with limited therapist support can be provided remotely, which has the potential to increase access. However, current evidence concerning low-intensity interventions is insufficient. We aimed to determine the clinical effectiveness of 2 forms of low-intensity CBT prior to high-intensity CBT, in adults meeting the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV criteria for OCD.This study was approved by the National Research Ethics Service Committee North West-Lancaster (reference number 11/NW/0276. All participants provided informed consent to take part in the trial. We conducted a 3-arm, multicentre randomised controlled trial in primary- and secondary-care United Kingdom mental health services. All patients were on a waiting list for therapist-led CBT (treatment as usual. Four hundred and seventy-three eligible patients were recruited and randomised. Patients had a median age of 33 years, and 60% were female. The majority were experiencing severe OCD. Patients received 1 of 2 low-intensity interventions: computerised CBT (cCBT; web-based CBT materials and limited telephone support through "OCFighter" or guided self-help (written CBT materials with limited telephone or face-to-face support. Primary comparisons concerned OCD symptoms, measured using the Yale-Brown Obsessive Compulsive Scale-Observer-Rated (Y-BOCS-OR at 3, 6, and 12 months. Secondary outcomes included health-related quality of life, depression, anxiety, and

  12. Yeast cell inactivation related to local heating induced by low-intensity electric fields with long-duration pulses.

    Science.gov (United States)

    Guyot, Stéphane; Ferret, Eric; Boehm, Jean-Baptiste; Gervais, Patrick

    2007-01-25

    The effects of electric field (EF) treatments on Saccharomyces cerevisiae viability were investigated using a PG200 electroporator (Hoefer Scientific Instrument, San Fransisco, CA, USA) with specific attention to induced thermal effects on cell death. Lethal electric fields (1.5 kV cm(-1) for 5 s) were shown to cause heat variations in the cell suspension medium (water+glycerol), while corresponding classical thermal treatments at equivalent temperatures had no effect on the cells viability. Variations of the electrical conductivity of the intra- and extracellular matrix caused by ions and solutes transfer across the membrane were shown to be involved in the observed heating. The results permitted to build a theoretical model for the temperature variations induced by electric fields. Using this model and the electrical conductivity of the different media, a plausible explanation of the cell death induced by low-intensity electric fields with long-duration pulses has been proposed. Indeed, cell mortality could in part be caused by direct and indirect effects of electric fields. Direct effects are related to well known electromechanical phenomena, whereas indirect effects are related to secondary thermal stress caused by plasma membrane thermoporation. This thermoporation was attributed to electrical conductivity variations and the corresponding intracellular heating.

  13. [Effect of Low-Intensity 900 MHz Frequency Electromagnetic Radiation on Rat Brain Enzyme Activities Linked to Energy Metabolism].

    Science.gov (United States)

    Petrosyan, M S; Nersesova, L S; Gazaryants, M G; Meliksetyan, G O; Malakyan, M G; Bajinyan, S A; Akopian, J I

    2015-01-01

    The research deals with the effect of low-intensity 900 MHz frequency electromagnetic radiation (EMR), power density 25 μW/cm2, on the following rat brain and blood serum enzyme activities: creatine kinase (CK), playing a central role in the process of storing and distributing the cell energy, as well as alanine aminotransferase (ALT) and aspartate aminotransferase (AST) that play a key role in providing the conjunction of carbohydrate and amino acid metabolism. The comparative analysis of the changes in the enzyme activity studied at different times following the two-hour single, as well as fractional, radiation equivalent of the total time showed that the most radiosensitive enzyme is the brain creatine kinase, which may then be recommended as a marker of the radio frequency radiation impact. According to the analysis of the changing dynamics of the CK, ALT and AST activity level, with time these changes acquire the adaptive character and are directed to compensate the damaged cell energy metabolism.

  14. [Effect of low-intensity 900 MHz frequency electromagnetic radiation on rat liver and blood serum enzyme activities].

    Science.gov (United States)

    Nersesova, L S; Petrosian, M S; Gazariants, M G; Mkrtchian, Z S; Meliksetian, G O; Pogosian, L G; Akopian, Zh I

    2014-01-01

    The comparative analysis of the rat liver and blood serum creatine kinase, alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase and purine nucleoside phosphorylase post-radiation activity levels after a total two-hour long single and fractional exposure of the animals to low-intensity 900 MHz frequency electromagnetic field showed that the most sensitive enzymes to the both schedules of radiation are the liver creatine kinase, as well as the blood serum creatine kinase and alkaline phosphatase. According to the comparative analysis of the dynamics of changes in the activity level of the liver and blood serum creatine kinase, alanine aminotransferase, aspartate aminotransferase and purine nucleoside phosphorylase, both single and fractional radiation schedules do not affect the permeability of a hepatocyte cell membrane, but rather cause changes in their energetic metabolism. The correlation analysis of the post-radiation activity level changes of the investigated enzymes did not reveal a clear relationship between them. The dynamics of post-radiation changes in the activity of investigated enzyme levels following a single and short-term fractional schedules of radiation did not differ essentially.

  15. Radio and chemioinduced oral mucositis treatment: comparison between conventional drug protocol and treatments with low intensity lasers

    International Nuclear Information System (INIS)

    Alencar, Anelise Ribeiro Peixoto

    2011-01-01

    In this clinical study verified the effects of low intensity laser in the prevention and treatment of oral mucositis radio and/or chemical induced. Thirty one patients with head and neck cancer were selected before being submitted to cancer exclusive radiotherapy or radio and associated chemotherapy. The patients were distributed into three randomly groups as follows: group 1- (control) conventional medicine treatment; group 2 - conventional medicine treatment and daily laser therapy as soon as grade two oral mucositis appeared; group 3 - conventional medicine treatment and daily laser therapy to be initiated immediately before radiotherapy sessions.The irradiation parameters were: wavelength of 660nm, potency of 100mW, continuous mode, punctual application, 2J energy on thirty pre-determined 30 points, with 20s of exposure per point. The control group received medical treatment which consisted in using a set of preventive and therapeutic approach for acute radiation-induced adverse effects. Results were evaluated observing occurrence and grade of oral mucositis, score of pain, loss of body mass, use of nasogastric sound line, internment and interruption of oncologic treatment due to oral mucositis. The results showed that the preventive protocol as used was the most effective in prevention and treatment of oral mucositis and that its daily application contributed in relieving the painful symptomatology so collaborating to maintain and/or bettering the life quality of oncologic patients. (author)

  16. Radiation-induced liver injury showing low intensity on T2-weighted images noted in Budd-Chiari syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Harushi [Tokyo Univ. (Japan). Graduate School of Medicine; Yoshioka, Hiroshi; Saida, Yukihisa; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Mori, Kensaku [Tsukuba Univ., Ibaraki (Japan). Hospital; Ahmadi, T. [Shahid Beheshti Univ. of Medical Sciences, Teheran (Iran, Islamic Republic of); Okumura, Toshiyuki [Ibaraki Prefectural Central Hospital, Tomobe (Japan)

    2002-04-01

    Although it is documented that radiation can cause density or intensity changes on computed tomography or MR imaging in the irradiated hepatic parenchyma, few researchers have reported or understood the MR presentation of changes in hepatic parenchyma following radiotherapy in the patient with Budd-Chiari syndrome. The purpose of this study was to investigate the MR appearance of hepatic radiation injury in Budd-Chiari syndrome and to consider the underlying pathophysiology. The MR examinations of two patients with Budd-Chiari syndrome was compared with those of 11 patients without Budd-Chiari syndrome. The two groups, both of which suffered from hepatocellular carcinoma, underwent 50-72 Gy of proton-beam irradiation during a period of 14-43 days. Examinations including T1- and T2-weighted imaging, superparamagnetic iron oxide-enhanced imaging, and dynamic study were performed 3-10 weeks after the end of irradiation. Radiation-induced hepatic injury was observed as a low-intensity area on T2-weighted images and on delayed phase images of dynamic study in the Budd-Chiari patients, and as iso- or high-intensity areas on both images in the patients without Budd-Chiari syndrome. US-guided needle biopsy from the irradiated area in one patient with Budd-Chiari syndrome revealed mostly necrotic tissue and fibrous tissue. These MR features of hepatic radiation injury in Budd-Chiari syndrome were considered to be due to severe hepatic fibrosis. (author)

  17. Sample Entropy and Traditional Measures of Heart Rate Dynamics Reveal Different Modes of Cardiovascular Control During Low Intensity Exercise

    Directory of Open Access Journals (Sweden)

    Matthias Weippert

    2014-10-01

    Full Text Available Nonlinear parameters of heart rate variability (HRV have proven their prognostic value in clinical settings, but their physiological background is not very well established. We assessed the effects of low intensity isometric (ISO and dynamic (DYN exercise of the lower limbs on heart rate matched intensity on traditional and entropy measures of HRV. Due to changes of afferent feedback under DYN and ISO a distinct autonomic response, mirrored by HRV measures, was hypothesized. Five-minute inter-beat interval measurements of 43 healthy males (26.0 ± 3.1 years were performed during rest, DYN and ISO in a randomized order. Blood pressures and rate pressure product were higher during ISO vs. DYN (p < 0.001. HRV indicators SDNN as well as low and high frequency power were significantly higher during ISO (p < 0.001 for all measures. Compared to DYN, sample entropy (SampEn was lower during ISO (p < 0.001. Concluding, contraction mode itself is a significant modulator of the autonomic cardiovascular response to exercise. Compared to DYN, ISO evokes a stronger blood pressure response and an enhanced interplay between both autonomic branches. Non-linear HRV measures indicate a more regular behavior under ISO. Results support the view of the reciprocal antagonism being only one of many modes of autonomic heart rate control. Under different conditions; the identical “end product” heart rate might be achieved by other modes such as sympathovagal co-activation as well.

  18. Gingival healing after gingivectomy procedure and low intensity laser irradiation. A clinical and biometrical study in anima nobile

    International Nuclear Information System (INIS)

    Amorim, Jose Claudio Faria

    2001-01-01

    For the present study seven patients presenting periodontal disease were selected in a way that they required the performance of gingivectomy procedure in the region of premolars in both sides, being this in the upper or lower region. After the surgical procedure one side was submitted to low intensity laser radiation, wavelength 685 nm, power 50 mW and fluency of 4J/cm 2 , contact mode. The other side was used as a control, not receiving any laser irradiation. Healing process for both sides, was clinically and biometrically evaluated and compared using photographs for the periods: pre-operative, immediate post-operative, 3, 7,14,21, 28 and 35 days. The analysis was performed by 3 specialists in Periodontology considering aspects of healing. Results were submitted to statistical analysis. Biometrical evaluation showed improvement of healing for the period of 21 and 28 days in the lased group. Clinical evaluation showed better reparation mainly after the third day for the active group. Laser group was considered to present an improved healing when compared to the control group. (author)

  19. Randomized, Double-Blind, and Placebo-Controlled Clinic Report of Intranasal Low-Intensity Laser Therapy on Vascular Diseases

    Directory of Open Access Journals (Sweden)

    Timon Cheng-Yi Liu

    2012-01-01

    Full Text Available The intranasal low intensity GaInP/AlGaInP diode 650 nm laser therapy (ILGLT might improve blood lipid and hemorheologic behavior of patients in view of its previous research, but it should be further supported by a randomized, double-blind, and placebo-controlled clinical study. In this paper, 90 patients with coronary heart disease or cerebral infarction were randomly divided into two groups, 60 in the treatment group and 30 in the control group, and were blindly treated with ILGLT at 8.38 and 0 mW/cm2 for 30 min each time once a day ten days each session for two sessions between which there were three days for rest, respectively. Fasting blood lipid such as total cholesterol and low/high-density lipoprotein cholesterol and hemorheologic behavior such as blood viscosity, plasma viscosity, redox viscosity and red blood cell aggregation were assessed before the first treatment and after the two sessions and were found to be significantly improved by ILGLT. It was concluded that ILGLT may improve blood lipid and hemorheologic behavior of patients with coronary heart disease or cerebral infarction.

  20. Evaluation of the ocular protection for low intensity therapeutic lasers; Avaliacao da protecao ocular para lasers terapeuticos em baixa intensidade

    Energy Technology Data Exchange (ETDEWEB)

    Cordon, Rosely

    2003-07-01

    The low intensity laser therapy (LILT) has been extensively used in medicine and dentistry presenting positive effects. However, the laser radiation can also cause adverse effects. Due to the ocular focalization property, in the wavelength from 400 to 1400 nm, the retina is more susceptible to damage by radiation than any other part of the human body. Then, the ocular protection is frequently emphasized. This protection must attenuate the radiation to a safe level. The International Electrotechnical Commission (IEC) standard IEC 60825-1 suggests safety requirements for medical laser equipment, including the ocular protection, based on maximum permissible exposure levels. The Brazilian legislation adopts a corresponding IEC standard, the NBR IEC 601.2.22, for safety requirements. The aim of this study was to analyze the adequacy of the ocular protectors furnished by four laser equipment manufacturers, commercially available in Brazil, commonly used for LILT. For this purpose, the laser equipment and the respective ocular protectors were characterized. The adequacy was verified according to the IEC standards. It was found, among other results, ocular protectors attenuating to safe levels the radiation emitted by the respective laser equipment, however, presenting inadequate visual transmission. Inefficient protection and protection indicated in cases where they were not necessary were also observed. (author)