WorldWideScience

Sample records for loudspeaker-based room auralization

  1. Validation of a loudspeaker-based room auralization system using speech intelligibility measures

    DEFF Research Database (Denmark)

    Favrot, Sylvain Emmanuel; Buchholz, Jörg

    2009-01-01

    A novel loudspeaker-based room auralization (LoRA) system has been proposed to generate versatile and realistic virtual auditory environments (VAEs) for investigating human auditory perception. This system efficiently combines modern room acoustic models with loudspeaker auralization using either...

  2. A loudspeaker-based room auralization system for auditory research

    DEFF Research Database (Denmark)

    Favrot, Sylvain Emmanuel

    to systematically study the signal processing of realistic sounds by normal-hearing and hearing-impaired listeners, a flexible, reproducible and fully controllable auditory environment is needed. A loudspeaker-based room auralization (LoRA) system was developed in this thesis to provide virtual auditory...... in reverberant environments. Each part of the early incoming sound to the listener was auralized with either higher-order Ambisonic (HOA) or using a single loudspeaker. The late incoming sound was auralized with a specific algorithm in order to provide a diffuse reverberation with minimal coloration artifacts...... assessed the impact of the auralization technique used for the early incoming sound (HOA or single loudspeaker) on speech intelligibility. A listening test showed that speech intelligibility experiments can be reliably conducted with the LoRA system with both techniques. The second evaluation investigated...

  3. Evaluating the auralization of a small room in a virtual sound environment using objective room acoustic measures

    DEFF Research Database (Denmark)

    Ahrens, Axel; Marschall, Marton; Dau, Torsten

    2016-01-01

    To study human auditory perception in realistic environments, loudspeaker-based reproduction techniques have recently become state-of-the-art. To evaluate the accuracy of a simulation-based room auralization of a small room, objective measures, such as early-decay-time (EDT), reverberation time...... of the room. The auralizations were generated using the loudspeaker-based room auralization toolbox (LoRA; Favrot and Buchholz, 2010) and reproduced in a 64-channel loudspeaker array, set up in an anechoic chamber. Differences between the objective measures evaluated in the real and the virtual room were......, clarity, interaural cross-correlation (IACC), and the speech transmission index were measured in an IEC listening room for 28 source-receiver combinations. The room was then modeled in the room acoustics software ODEON, and the same objective measures were also evaluated for the auralized version...

  4. Time based room correction system for low frequencies using multiple loudspeakers

    DEFF Research Database (Denmark)

    Nielsen, Sofus Birkedal; Celestinos, Adrian

    2007-01-01

      Improving sound from loudspeakers in a room is a big issue. We are facing a rather complicated and serious problem, as one can experience very big variations in sound pressure level - up to 30 dB - in a room, especially at low frequencies. An innovative way of looking at the problem in the time......-domain by the construction of a finite-difference time-domain approximation program (FDTD) has lead to a novel and simple solution also working in the time-domain called Controlled Acoustically Bass System (CABS). Working in the time-domain CABS includes additional cancelling loudspeakers at the back wall in order to remove...

  5. Optimizing placement and equalization of multiple low frequency loudspeakers in rooms

    DEFF Research Database (Denmark)

    Celestinos, Adrian; Nielsen, Sofus Birkedal

    2005-01-01

    loudspeakers in rooms a simulation tool has been created based on finite-difference time-domain approximations (FDTD). Simulations have shown that by increasing the number of loudspeakers and modifying their placement a significant improvement is achieved. A more even sound pressure level distribution along...... a listening area is obtained. The placement of loudspeakers has been optimized. Furthermore an equalization strategy can be implemented for optimization purpose. This solution can be combined with multi channel sound systems....

  6. Low frequency sound field enhancement system for rectangular rooms, using multiple loudspeakers

    DEFF Research Database (Denmark)

    Celestinos, Adrian

    2007-01-01

    The scope of this PhD dissertation is within the performance of loudspeakers in rooms at low frequencies. The research concentrates on the improvement of the sound level distribution in rooms produced by loudspeakers at low frequencies. The work focuses on seeing the problem acoustically...... and solving it in the time domain. Loudspeakers are the last link in the sound reproduction chain, and they are typically placed in small or medium size rooms. When low frequency sound is radiated by a loudspeaker the sound level distribution along the room presents large deviations. This is due...... to the multiple reflection of sound at the rigid walls of the room. This may cause level differences of up to 20 dB in the room. Some of these deviations are associated with the standing waves, resonances or anti resonances of the room. The understanding of the problem is accomplished by analyzing the behavior...

  7. Perceptual effects in auralization of virtual rooms

    Science.gov (United States)

    Kleiner, Mendel; Larsson, Pontus; Vastfjall, Daniel; Torres, Rendell R.

    2002-05-01

    By using various types of binaural simulation (or ``auralization'') of physical environments, it is now possible to study basic perceptual issues relevant to room acoustics, as well to simulate the acoustic conditions found in concert halls and other auditoria. Binaural simulation of physical spaces in general is also important to virtual reality systems. This presentation will begin with an overview of the issues encountered in the auralization of room and other environments. We will then discuss the influence of various approximations in room modeling, in particular, edge- and surface scattering, on the perceived room response. Finally, we will discuss cross-modal effects, such as the influence of visual cues on the perception of auditory cues, and the influence of cross-modal effects on the judgement of ``perceived presence'' and the rating of room acoustic quality.

  8. Low-Frequency Loudspeaker-Room Simulation Using Finite Differences in the Time Domain-Part 1: Analysis

    DEFF Research Database (Denmark)

    Celestinos, Adrian; Nielsen, Sofus Birkedal

    2008-01-01

    Small- and medium-size rectangular rooms have a strong influence on the low-frequency performance of loudspeakers. A simulation program based on the finite-difference time-domain (FDTD) method is introduced to analyze the sound field produced by loudspeakers in rectangular rooms at low frequencies...

  9. Applications of a plane wave based room correction system for low frequencies using multiple loudspeakers

    DEFF Research Database (Denmark)

    Celestinos, Adrian; Nielsen, Sofus Birkedal

    2008-01-01

    evaluated by using a computer simulation program based on the Finite Difference Time Domain Method (FDTD). CABS has been simulated in a small car cabin and in an irregular room. Non-ideal placement of loudspeakers in CABS have been evaluated. The influence of utilizing CABS with different types...

  10. Equalization of Loudspeaker and Room Responses Using Kautz Filters: Direct Least Squares Design

    Directory of Open Access Journals (Sweden)

    Karjalainen Matti

    2007-01-01

    Full Text Available DSP-based correction of loudspeaker and room responses is becoming an important part of improving sound reproduction. Such response equalization (EQ is based on using a digital filter in cascade with the reproduction channel to counteract the response errors introduced by loudspeakers and room acoustics. Several FIR and IIR filter design techniques have been proposed for equalization purposes. In this paper we investigate Kautz filters, an interesting class of IIR filters, from the point of view of direct least squares EQ design. Kautz filters can be seen as generalizations of FIR filters and their frequency-warped counterparts. They provide a flexible means to obtain desired frequency resolution behavior, which allows low filter orders even for complex corrections. Kautz filters have also the desirable property to avoid inverting dips in transfer function to sharp and long-ringing resonances in the equalizer. Furthermore, the direct least squares design is applicable to nonminimum-phase EQ design and allows using a desired target response. The proposed method is demonstrated by case examples with measured and synthetic loudspeaker and room responses.

  11. Investigations of incorporating source directivity into room acoustics computer models to improve auralizations

    Science.gov (United States)

    Vigeant, Michelle C.

    Room acoustics computer modeling and auralizations are useful tools when designing or modifying acoustically sensitive spaces. In this dissertation, the input parameter of source directivity has been studied in great detail to determine first its effect in room acoustics computer models and secondly how to better incorporate the directional source characteristics into these models to improve auralizations. To increase the accuracy of room acoustics computer models, the source directivity of real sources, such as musical instruments, must be included in the models. The traditional method for incorporating source directivity into room acoustics computer models involves inputting the measured static directivity data taken every 10° in a sphere-shaped pattern around the source. This data can be entered into the room acoustics software to create a directivity balloon, which is used in the ray tracing algorithm to simulate the room impulse response. The first study in this dissertation shows that using directional sources over an omni-directional source in room acoustics computer models produces significant differences both in terms of calculated room acoustics parameters and auralizations. The room acoustics computer model was also validated in terms of accurately incorporating the input source directivity. A recently proposed technique for creating auralizations using a multi-channel source representation has been investigated with numerous subjective studies, applied to both solo instruments and an orchestra. The method of multi-channel auralizations involves obtaining multi-channel anechoic recordings of short melodies from various instruments and creating individual channel auralizations. These auralizations are then combined to create a total multi-channel auralization. Through many subjective studies, this process was shown to be effective in terms of improving the realism and source width of the auralizations in a number of cases, and also modeling different

  12. Low frequency sound field enhancement system for rectangular rooms using multiple low frequency loudspeakers

    DEFF Research Database (Denmark)

    Celestinos, Adrian; Nielsen, Sofus Birkedal

    2006-01-01

    an enhancement system with extra loudspeakers the sound pressure level distribution along the listening area presents a significant improvement in the subwoofer frequency range. The system is simulated and implemented on the three different rooms and finally verified by measurements on the real rooms.......Rectangular rooms have strong influence on the low frequency performance of loudspeakers. Simulations of three different room sizes have been carried out using finite-difference time-domain method (FDTD) in order to predict the behaviour of the sound field at low frequencies. By using...

  13. Evaluation of room acoustic qualities and defects by use of auralization

    DEFF Research Database (Denmark)

    Rindel, Jens Holger

    2004-01-01

    Auralizations generated by room acoustic computer modeling programs may be used as a tool for evaluation of acoustic qualities and defects, some of which are not easily detected by objective measures. Examples include reverberance, flutter echoes, perceived room size and distance, apparent source...... that the modeling of source directivity and the late room reflections (the reverberation tail) need careful consideration in order to achieve reliable and realistic sounding results. However, when implemented in the software the application for practical use can be simple and quick....... width, listener envelopment, and sound propagation in coupled rooms. In order to reach a sufficiently high level of realism in auralizations for such room acoustic applications it is necessary that all parts of the simulation chain are modeled with sufficient accuracy. In particular it is found...

  14. Auralization of airborne sound insulation including the influence of source room

    DEFF Research Database (Denmark)

    Rindel, Jens Holger

    2006-01-01

    The paper describes a simple and acoustically accurate method for the auralization of airborne sound insulation between two rooms by means of a room acoustic simulation software (ODEON). The method makes use of a frequency independent transparency of the transmitting surface combined...... with a frequency dependent power setting of the source in the source room. The acoustic properties in terms of volume and reverberation time as well as the area of the transmitting surface are all included in the simulation. The user only has to select the position of the source in the source room and the receiver...... of the transmitting surface is used for the simulation of sound transmission. Also the reduced clarity of the auralization due to the reverberance of the source room is inherent in the method. Currently the method is restricted to transmission loss data in octave bands....

  15. The interaction between room and musical instruments studied by multi-channel auralization

    DEFF Research Database (Denmark)

    Rindel, Jens Holger; Otondo, Felipe

    2005-01-01

    in the anechoic recording. With this technique the variations in sound radiation from the musical instrument during the performance e.g. due to changes in level or movements can be reproduced with the influence of the surrounding room surfaces. Examples include a grand piano and a clarinet.......The directivity of musical instruments is very complicated and typically changes from one tone to the next. So, instead of measuring the average directivity, a multi-channel auralization method has been developed, which allows a highly accurate and realistic sounding auralization of musical...... instruments in rooms. Anechoic recordings have been made with 5 and 13 evenly distributed microphones around the musical instrument. The reproduction is made with a room acoustics simulation software using a compound source, which is in fact a number of highly directive sources, one for each of the channels...

  16. Low frequency sound field control for loudspeakers in rectangular rooms using CABS (Controlled Acoustical Bass System)

    DEFF Research Database (Denmark)

    Nielsen, Sofus Birkedal; Celestinos, Adrian

    2010-01-01

    Rectangular rooms are the most common shape for sound reproduction, but at low frequencies the reflections from the boundaries of the room cause large spatial variations in the sound pressure level.  Variations up to 30 dB are normal, not only at the room modes, but basically at all frequencies....... As sound propagates in time, it seems natural that the problems can best be analyzed and solved in the time domain. A time based room correction system named CABS (Controlled Acoustical Bass System) has been developed for sound reproduction in rectangular listening rooms. It can control the sound...... sound field in the whole room, and short impulse response.  In a standard listening room (180 m3) only 4 loudspeakers are needed, 2 more than a traditional stereo setup. CABS is controlled by a developed DSP system. The time based approached might help with the understanding of sound field control...

  17. Investigations of Orchestra Auralizations Using the Multi-Channel Multi-Source Auralization Technique

    DEFF Research Database (Denmark)

    Vigeant, Michelle; Wang, Lily M.; Rindel, Jens Holger

    2008-01-01

    a multi-channel multi-source auralization technique, involving individual five-channel anechoic recordings of each instrumental part of two symphonies. In the first study, these auralizations were subjectively compared to orchestra auralizations made using (a) a single omni-directional source, (b......) a surface source, and (c) single-channel multi-source method. Results show that the multi-source auralizations were rated to be more realistic than the surface source ones and to have larger source width than the single omni-directional source auralizations. No significant differences were found between......Room acoustics computer modeling is a tool for generating impulse responses and auralizations from modeled spaces. The auralizations are commonly made from a single-channel anechoic recording of solo instruments. For this investigation, auralizations of an entire orchestra were created using...

  18. Coupled auralization and virtual video for immersive multimedia displays

    Science.gov (United States)

    Henderson, Paul D.; Torres, Rendell R.; Shimizu, Yasushi; Radke, Richard; Lonsway, Brian

    2003-04-01

    The implementation of maximally-immersive interactive multimedia in exhibit spaces requires not only the presentation of realistic visual imagery but also the creation of a perceptually accurate aural experience. While conventional implementations treat audio and video problems as essentially independent, this research seeks to couple the visual sensory information with dynamic auralization in order to enhance perceptual accuracy. An implemented system has been developed for integrating accurate auralizations with virtual video techniques for both interactive presentation and multi-way communication. The current system utilizes a multi-channel loudspeaker array and real-time signal processing techniques for synthesizing the direct sound, early reflections, and reverberant field excited by a moving sound source whose path may be interactively defined in real-time or derived from coupled video tracking data. In this implementation, any virtual acoustic environment may be synthesized and presented in a perceptually-accurate fashion to many participants over a large listening and viewing area. Subject tests support the hypothesis that the cross-modal coupling of aural and visual displays significantly affects perceptual localization accuracy.

  19. A loudspeaker-based room auralization system for auditory perception research

    DEFF Research Database (Denmark)

    Buchholz, Jörg; Favrot, Sylvain Emmanuel

    2009-01-01

    Most research on basic auditory function has been conducted in anechoic or almost anechoic environments. The knowledge derived from these experiments cannot directly be transferred to reverberant environments. In order to investigate the auditory signal processing of reverberant sounds....... This system provides a flexible research platform for conducting auditory experiments with normal-hearing, hearing-impaired, and aided hearing-impaired listeners in a fully controlled and realistic environment. This includes measures of basic auditory function (e.g., signal detection, distance perception......) and measures of speech intelligibility. A battery of objective tests (e.g., reverberation time, clarity, interaural correlation coefficient) and subjective tests (e.g., speech reception thresholds) is presented that demonstrates the applicability of the LoRA system....

  20. Error Correction of Loudspeakers

    DEFF Research Database (Denmark)

    Pedersen, Bo Rohde

    of a nonlinear feed forward controller. System identification is used for tracking the loudspeaker parameters. Different system identification methods are reviewed, and the investigations ends with a simple FIR based algorithm. Finally, the ­parameter tracking system is tested with music signals on a 6½ inch......Throughout this thesis, the topic of electrodynamic loudspeaker unit design and modelling are reviewed. The research behind this project has been to study loudspeaker design, based on new possibilities introduced by including digital signal processing, and thereby achieving more freedom...... in loudspeaker unit design. This freedom can be used for efficiency improvements where different loudspeaker design cases show design opportunities. Optimization by size and efficiency, instead of flat frequency response and linearity, is the basis of the loudspeaker efficiency designs studied. In the project...

  1. Validation of an auralization system

    DEFF Research Database (Denmark)

    Christensen, Claus Lynge; Weitze, Christoffer Andreas; Rindel, Jens Holger

    2001-01-01

    The room acoustics program odeon provides auralization using fully filtered binaural room impulse responses, each reflection being filtered through nine octave bands and a set of head-related transfer functions. Using the full filtering scheme allows, in principle, a complete audible presentation...

  2. Optimization of Virtual Loudspeakers for Spatial Room Acoustics Reproduction with Headphones

    Directory of Open Access Journals (Sweden)

    Otto Puomio

    2017-12-01

    Full Text Available The use of headphones in reproducing spatial sound is becoming more and more popular. For instance, virtual reality applications often use head-tracking to keep the binaurally reproduced auditory environment stable and to improve externalization. Here, we study one spatial sound reproduction method over headphones, in particular the positioning of the virtual loudspeakers. The paper presents an algorithm that optimizes the positioning of virtual reproduction loudspeakers to reduce the computational cost in head-tracked real-time rendering. The listening test results suggest that listeners could discriminate the optimized loudspeaker arrays for renderings that reproduced a relatively simple acoustic conditions, but optimized array was not significantly different from equally spaced array for a reproduction of a more complex case. Moreover, the optimization seems to change the perceived openness and timbre, according to the verbal feedback of the test subjects.

  3. Loudspeaker handbook

    CERN Document Server

    Eargle, John

    2003-01-01

    The second edition of Loudspeaker Handbook follows the same general outlines as the highly successful first edition and has been augmented and updated in many areas of technology. Most notable are the developments in large-scale, programmable line arrays, distributed mode loudspeakers, and ultrasonic-based audio transduction. Additionally, the core chapters on low frequency systems, system concepts, and horn systems have been expanded to include both more analytical material and a richer array of examples. Much of the success of the first edition has been due to its accessibility both to loudspeaker engineers and to lay technicians working in the field - a point of view the author maintains in the present work. A full understanding of the underlying technology requires a fairly rigorous engineering background through the second year of professional study. At the same time, the generous use of graphs, with their intuitive thrust, will be useful to all readers. Loudspeaker Handbook, Second Edition continues to ...

  4. Micro Loudspeaker Behaviour versus 6½" Driver, Micro Loudspeaker Parameter Drift

    DEFF Research Database (Denmark)

    Pedersen, Bo Rohde

    2010-01-01

    This study tested micro loudspeaker behavior from the perspective of loudspeaker parameter drift. The main difference between traditional transducers and micro loudspeakers, apart from their size, is their suspension construction. The suspension generally is a loudspeaker's most unstable parameter......, and the study investigated temperature drift and signal dependency. There is investigated three different micro loudspeakers and compared their behavior to that of a typical bass mid-range loudspeaker unit. There is measured all linear loudspeaker parameters at different temperatures....

  5. Five aspects of maximizing objectivity from perceptual evaluations of loudspeakers

    DEFF Research Database (Denmark)

    Volk, Christer Peter; Bech, Søren; Pedersen, Torben H.

    2015-01-01

    of data from the listening evaluations. This paper addresses the following subset of aspects for increasing the objectivity of data from listening tests: The choice of perceptual attributes, relevance of perceptual attributes, choice of loudness equalisation strategy, optimum listening room specifications......A literature study was conducted focusing on maximizing objectivity of results from listening evaluations aimed at establishing the relationship between physical and perceptual measurements of loudspeakers. The purpose of the study was to identify and examine factors influencing the objectivity......, as well as loudspeaker listening in-situ vs. listening to recordings of loudspeakers over headphones....

  6. A virtual auditory environment for investigating the auditory signal processing of realistic sounds

    DEFF Research Database (Denmark)

    Favrot, Sylvain Emmanuel; Buchholz, Jörg

    2008-01-01

    In the present study, a novel multichannel loudspeaker-based virtual auditory environment (VAE) is introduced. The VAE aims at providing a versatile research environment for investigating the auditory signal processing in real environments, i.e., considering multiple sound sources and room...... reverberation. The environment is based on the ODEON room acoustic simulation software to render the acoustical scene. ODEON outputs are processed using a combination of different order Ambisonic techniques to calculate multichannel room impulse responses (mRIR). Auralization is then obtained by the convolution...... the VAE development, special care was taken in order to achieve a realistic auditory percept and to avoid “artifacts” such as unnatural coloration. The performance of the VAE has been evaluated and optimized on a 29 loudspeaker setup using both objective and subjective measurement techniques....

  7. Non-linear Loudspeaker Unit Modelling

    DEFF Research Database (Denmark)

    Pedersen, Bo Rohde; Agerkvist, Finn T.

    2008-01-01

    Simulations of a 6½-inch loudspeaker unit are performed and compared with a displacement measurement. The non-linear loudspeaker model is based on the major nonlinear functions and expanded with time-varying suspension behaviour and flux modulation. The results are presented with FFT plots of thr...... frequencies and different displacement levels. The model errors are discussed and analysed including a test with loudspeaker unit where the diaphragm is removed....

  8. Loudspeaker impedance emulator for multi resonant systems

    DEFF Research Database (Denmark)

    Iversen, Niels Elkjær; Knott, Arnold

    2015-01-01

    Specifying the performance of audio amplifiers is typically done by playing sine waves into a pure ohmic load. However real loudspeaker impedances are not purely ohmic but characterised by its electrical, mechanical and acoustical properties. Therefore a loudspeaker emulator capable of adjusting...... its impedance to that of a given loudspeaker is desired for measurement purposes. An adjustable RLC based emulator is implemented with switch controlled capacitors, air gap controlled inductors and potentiometers. Calculations and experimental results are compared and show that it is possible...... to emulate the loudspeaker impedance infinite baffle-, closed box- and the multi resonant vented box-loudspeaker by tuning the component values in the proposed circuit. Future work is outlined and encourage that the proposed impedance emulator is used as part of a control circuit in a switch-mode based...

  9. Graphene Electrostatic Loudspeaker as an Alternative to Current Loudspeaker Designs

    Institute of Scientific and Technical Information of China (English)

    Runyuan Liu

    2014-01-01

    As a new nanomaterial graphene has broad application prospects.Its mechanical strength,low mass and other aspects of the superior features,enable the production of lighter, better quality loudspeakers.This paper wil brielfy describe the physical and structural properties of graphene,analyze the structure and advantages of graphene loudspeakers and then com-pare it with other loudspeakers.

  10. A novel method for perceptual assessment of small room acoustics using rapid sensory analysis

    DEFF Research Database (Denmark)

    Kaplanis, Neofytos; Bech, Søren; Lokki, Tapio

    2016-01-01

    presented with auralized sound over a loudspeaker array and followed a rapid sensory analysis protocol. The elicited attributes and ratings are analyzed and possible links to the acoustical properties of these spaces are discussed. [This study is a part of Marie Curie Network on Dereverberation...

  11. A new method for the radiation representation of musical instruments in auralizations

    DEFF Research Database (Denmark)

    Rindel, Jens Holger; Otondo, Felipe

    2005-01-01

    A new method for the representation of sound sources that vary their directivity in time in auralizations is introduced. A recording method with multi-channel anechoic recordings is proposed in connection with the use of a multiple virtual source reproduction system in auralizations. Listening ex...... to be significant. Further applications of the method are considered for ensembles within room auralizations as well as in the field of studio recording techniques for large instruments....

  12. Experiments with a loudspeaker

    International Nuclear Information System (INIS)

    Kraftmakher, Yaakov

    2009-01-01

    A common moving-coil loudspeaker is useful for learning harmonic motion. A simple optical method is used to observe free and forced oscillations of the diaphragm of a loudspeaker. With a lock-in amplifier and data-acquisition system, the frequency response of the loudspeaker and its electrical impedance are automatically recorded versus frequency. From the measurements, it is easy to calculate electrical and mechanical parameters of the loudspeaker

  13. Loudspeaker Equalization with Post-Processing

    Directory of Open Access Journals (Sweden)

    Ser Wee

    2002-01-01

    Full Text Available Loudspeaker equalization is an essential technique in audio system design. A well-known equalization scheme is based on the deconvolution of the desired equalized response with the measured impulse response of the loudspeaker. In this paper, a post-processing scheme is combined with the deconvolution-based algorithm to provide a better equalization effect. Computer simulation results are given to demonstrate the significant improvement that can be achieved using this method.

  14. Subjective evaluation of auralizations created from multi-channel anechoic recordings of a talker in motion

    Science.gov (United States)

    Vigeant, Michelle C.; Wang, Lily M.

    2005-04-01

    A high degree of speech intelligibility is very important in educational environments. When designing such spaces, like classrooms, auralizations can be used to subjectively assess the degree of speech intelligibility and clarity. Auralizations are most commonly made by convolving the impulse response (IR) of an omni-directional source with a single channel anechoic speech recording. This paper explores the idea of using multi-channel recordings to create the auralizations, using a female talker in motion. An omni-directional source is split into quadrants and the IR is calculated for each section. These IR's are convolved with the appropriate channel of the anechoic recording and then the four auralizations are mixed to create one final auralization. The auralizations were made using four-channel anechoic recordings of a person walking on a platform while talking. Subjective tests were conducted to determine the ease with which subjects could identify the direction of the movement of the source in rooms with varying amounts of absorption. This method can be used to create more realistic classroom auralizations, as teachers typically move around the room as they teach. [Work supported by the National Science Foundation.

  15. Arrangements of a pair of loudspeakers for sound field control with double-layer arrays

    DEFF Research Database (Denmark)

    Chang, Jiho; Agerkvist, Finn T.; Olsen, Martin

    2013-01-01

    Recent studies have attempted to control sound fields, and also to reduce room reflections with a circular or spherical array of loudspeakers. One of the attempts was to suppress sound waves propagating to the walls outside the array with a circular double-layer array of loudspeakers. The double-layer...... array represents a set of a monopole and a dipole in the Kirchhoff-Helmholtz integral equation, and thus the distance between these layers should be short compared with the wavelength. In practice, however, this condition is occasionally hard to satisfy because of the sizes of loudspeaker cabinets...

  16. Investigation of Current Driven Loudspeakers

    DEFF Research Database (Denmark)

    Schneider, Henrik; Agerkvist, Finn T.; Knott, Arnold

    2015-01-01

    Current driven loudspeakers have previously been investigated but the literature is limited and the advantages and disadvantages are yet to be fully identified. This paper makes use of a non-linear loudspeaker model to analyse loudspeakers with distinct non-linear characteristics under voltage an......” woofer where a copper ring in the pole piece has not been implemented to compensate for eddy currents. However the drive method seems to be irrelevant for a 5” woofer where the compliance, force factor as well as the voice coil inductance has been optimized for linearity.......Current driven loudspeakers have previously been investigated but the literature is limited and the advantages and disadvantages are yet to be fully identified. This paper makes use of a non-linear loudspeaker model to analyse loudspeakers with distinct non-linear characteristics under voltage...

  17. A Recording-Based Method for Auralization of Rotorcraft Flyover Noise

    Science.gov (United States)

    Pera, Nicholas M.; Rizzi, Stephen A.; Krishnamurthy, Siddhartha; Fuller, Christopher R.; Christian, Andrew

    2018-01-01

    Rotorcraft noise is an active field of study as the sound produced by these vehicles is often found to be annoying. A means to auralize rotorcraft flyover noise is sought to help understand the factors leading to annoyance. Previous work by the authors focused on auralization of rotorcraft fly-in noise, in which a simplification was made that enabled the source noise synthesis to be based on a single emission angle. Here, the goal is to auralize a complete flyover event, so the source noise synthesis must be capable of traversing a range of emission angles. The synthesis uses a source noise definition process that yields periodic and aperiodic (modulation) components at a set of discrete emission angles. In this work, only the periodic components are used for the source noise synthesis for the flyover; the inclusion of modulation components is the subject of ongoing research. Propagation of the synthesized source noise to a ground observer is performed using the NASA Auralization Framework. The method is demonstrated using ground recordings from a flight test of the AS350 helicopter for the source noise definition.

  18. Challenges and solutions for realistic room simulation

    Science.gov (United States)

    Begault, Durand R.

    2002-05-01

    Virtual room acoustic simulation (auralization) techniques have traditionally focused on answering questions related to speech intelligibility or musical quality, typically in large volumetric spaces. More recently, auralization techniques have been found to be important for the externalization of headphone-reproduced virtual acoustic images. Although externalization can be accomplished using a minimal simulation, data indicate that realistic auralizations need to be responsive to head motion cues for accurate localization. Computational demands increase when providing for the simulation of coupled spaces, small rooms lacking meaningful reverberant decays, or reflective surfaces in outdoor environments. Auditory threshold data for both early reflections and late reverberant energy levels indicate that much of the information captured in acoustical measurements is inaudible, minimizing the intensive computational requirements of real-time auralization systems. Results are presented for early reflection thresholds as a function of azimuth angle, arrival time, and sound-source type, and reverberation thresholds as a function of reverberation time and level within 250-Hz-2-kHz octave bands. Good agreement is found between data obtained in virtual room simulations and those obtained in real rooms, allowing a strategy for minimizing computational requirements of real-time auralization systems.

  19. Simulation of realistic background noise using multiple loudspeakers

    DEFF Research Database (Denmark)

    Song, Wookeun; Marschall, Marton; Gil Corrales, Juan David

    2015-01-01

    Three methods for reproduction of sound using a maximum of eight loudspeakers were investigated in the context of testing telecommunication devices. They are the four-loudspeaker-based method as described in ETSI EG 202 396-1, Higher-Order ambisonics (HOA), and a matrix inversion method. HOA opti...

  20. Quantifying sound quality in loudspeaker reproduction

    NARCIS (Netherlands)

    Beerends, John G.; van Nieuwenhuizen, Kevin; van den Broek, E.L.

    2016-01-01

    We present PREQUEL: Perceptual Reproduction Quality Evaluation for Loudspeakers. Instead of quantifying the loudspeaker system itself, PREQUEL quantifies the overall loudspeakers' perceived sound quality by assessing their acoustic output using a set of music signals. This approach introduces a

  1. Synthesis of Room Impulse Responses for Variable Source Characteristics

    Directory of Open Access Journals (Sweden)

    M. Kunkemoeller

    2011-01-01

    Full Text Available Every acoustic source, e.g. a speaker, a musical instrument or a loudspeaker, generally has a frequency dependent characteristic radiation pattern, which is preeminent at higher frequencies. Room acoustic measurements nowadays only account for omnidirectional source characteristics. This motivates a measurement method that is capable of obtaining room impulse responses for these specific radiation patterns by using a superposition approach of several measurements with technically well-defined sound sources. We propose a method based on measurements with a 12-channel independentlydriven dodecahedron loudspeaker array rotated by an automatically controlled turntable.Radiation patterns can be efficiently described with the use of spherical harmonics representation. We propose a method that uses this representation for the spherical loudspeaker array used for the measurements and the target radiation pattern to be used for the synthesis.We show validating results for a deterministic test sound source inside in a small lecture hall.

  2. The influence of the directivity of musical instruments in a room

    DEFF Research Database (Denmark)

    Otondo, Felipe; Rindel, Jens Holger

    2004-01-01

    Measurements of the directivity of musical instruments are presented as part of the study of the influence of their representation in room acoustic simulations and auralizations. Pairs of measured and averaged directivities have been used both for room simulation comparisons and as a basis...... for listening experiments with auralizations. Room simulation results show a clear influence of the changes in the representation directivity on the distribution of acoustical parameters in the room. The results of the listening experiments with auralizations show that some changes produced by directivity...

  3. Online identification of linear loudspeakers parameters

    DEFF Research Database (Denmark)

    Pedersen, Bo Rohde; Rubak, Per

    2007-01-01

    Feed forward nonlinear error correction of loudspeakers can improve sound quality. For creating a realistic feed forward strategy identification of the loudspeaker parameters is needed. The strategy of the compensator is that the nonlinear behaviour of the loudspeakers has relatively small drift...

  4. Accelerometer Based Motional Feedback Integrated in a 2 3/4" Loudspeaker

    DEFF Research Database (Denmark)

    Bjerregaard, Ruben; Madsen, Anders Normann; Schneider, Henrik

    2016-01-01

    It is a well known fact that loudspeakers produce distortion when they are driven into large diaphragm displacements. Various methods exist to reduce distortion using forward compensation and feedback methods. Acceleration based motional feedback is one of these methods and was already thoroughly...

  5. Small Signal Loudspeaker Impedance Emulator

    DEFF Research Database (Denmark)

    Iversen, Niels Elkjær; Knott, Arnold

    2014-01-01

    Specifying the performance of audio amplifiers is typically done by playing sine waves into a pure ohmic load. However real loudspeaker impedances are not purely ohmic but characterized by the mechanical resonance between the mass of the diaphragm and the compliance of its suspension which vary...... from driver to driver. Therefore, a loudspeaker emulator capable of adjusting its impedance to that of a given driver is desired for measurement purposes. This paper proposes a loudspeaker emulator circuit for small signals. Simulations and experimental results are compared and show that it is possible...... to emulate the loudspeaker impedance with an electric circuit and that its resonance frequency can be changed by tuning two resistors....

  6. Small-signal Loudspeaker Impedance Emulator

    DEFF Research Database (Denmark)

    Knott, Arnold; Iversen, Niels Elkjær

    2014-01-01

    Specifying the performance of audio ampliers is typically done by playing sine waves into a pure ohmic load. However real loudspeaker impedances are not purely ohmic but characterised by the mechanical resonance between the mass of the diaphragm and the compliance of its' suspension which vary from...... driver to driver. Therefore a loudspeaker emulator capable of adjusting its' impedance to a given driver is in need for measurement purposes. This paper proposes a loudspeaker emulator circuit for small signals. Simulations and experimental results are compared and show that it is possible to emulate...... the loudspeaker impedance with an electric circuit and that its' resonance frequency can be changed by tuning two resistors....

  7. Frequency and Angular Resolution for Measuring, Presenting and Predicting Loudspeaker Polar Data

    DEFF Research Database (Denmark)

    Staffeldt, Henrik; Seidel, Felicity

    1996-01-01

    and approved by the AES Standards Committee. The work is a continuation of AES project AES-X07 and is presented to provide background for Call for Comment on Draft AES-5id-xxxx. AES information document for Room acoustics and sound reinforcement systems - Loudspeaker modeling and measurement - Frequency...

  8. Loudspeaker Design and Performance Evaluation

    Science.gov (United States)

    Mäkivirta, Aki Vihtori

    A loudspeaker comprises transducers converting an electrical driving signal into sound pressure, an enclosure working as a holder for transducers, front baffle and box to contain and eliminate the rear-radiating audio signal, and electronic components. Modeling of transducers as well as enclosures is treated in Chap. 32 of this handbook. The purpose of the present chapter is to shed light on the design choices and options for the electronic circuits conditioning the electrical signal fed into loudspeaker transducers in order to optimize the acoustic performance of the loudspeaker.

  9. A systematic study of binaural reproduction systems through loudspeakers

    DEFF Research Database (Denmark)

    Lacouture Parodi, Yesenia

    This Ph.D. thesis presents an investigation of the acoustical and psycho-acoustical characteristics of binaural reproduction systems through loudspeakers. The study was mainly focused on the characteristics of closely spaced loudspeakers – known as stereo-dipoles – when placed at different...... positions, e.g. in front of, above or in the back of the head. The main objective of this study is to set foundations for the design of a binaural reproduction system that is robust to head rotations and reduces front-back confusions. Different crosstalk cancellation techniques were investigated...... when the loudspeakers are placed above the head and that closely spaced loudspeakers are more robust to lateral displacements than wider span angles. Based on the results obtained from those experiments, a binaural reproduction system that uses three stereo-dipoles is proposed: one pair in front...

  10. Auralization fundamentals of acoustics, modelling, simulation, algorithms and acoustic virtual reality

    CERN Document Server

    Vorlander, Michael

    2007-01-01

    "Auralization" is the technique of creation and reproduction of sound on the basis of computer data. With this tool is it possible to predict the character of sound signals which are generated at the source and modified by reinforcement, propagation and transmission in systems such as rooms, buildings, vehicles or other technical devices. This book is organized as a comprehensive collection of the basics of sound and vibration, acoustic modelling, simulation, signal processing and audio reproduction. Implementations of the auralization technique are described using examples drawn from various fields in acoustic’s research and engineering, architecture, sound design and virtual reality.

  11. Modelling nonlinear viscoelastic behaviours of loudspeaker suspensions-like structures

    Science.gov (United States)

    Maillou, Balbine; Lotton, Pierrick; Novak, Antonin; Simon, Laurent

    2018-03-01

    Mechanical properties of an electrodynamic loudspeaker are mainly determined by its suspensions (surround and spider) that behave nonlinearly and typically exhibit frequency dependent viscoelastic properties such as creep effect. The paper aims at characterizing the mechanical behaviour of electrodynamic loudspeaker suspensions at low frequencies using nonlinear identification techniques developed in recent years. A Generalized Hammerstein based model can take into account both frequency dependency and nonlinear properties. As shown in the paper, the model generalizes existing nonlinear or viscoelastic models commonly used for loudspeaker modelling. It is further experimentally shown that a possible input-dependent law may play a key role in suspension characterization.

  12. Modeling of Lossy Inductance in Moving-Coil Loudspeakers

    DEFF Research Database (Denmark)

    Kong, Xiao-Peng; Agerkvist, Finn T.; Zeng, Xin-Wu

    2015-01-01

    The electrical impedance of moving-coil loudspeakers is dominated by the lossy inductance in high frequency range. Using the equivalent electrical circuit method, a new model for the lossy inductance based on separate functions for the magnitude and phase of the impedance is presented. The electr......The electrical impedance of moving-coil loudspeakers is dominated by the lossy inductance in high frequency range. Using the equivalent electrical circuit method, a new model for the lossy inductance based on separate functions for the magnitude and phase of the impedance is presented...

  13. Efficient Non Linear Loudspeakers

    DEFF Research Database (Denmark)

    Petersen, Bo R.; Agerkvist, Finn T.

    2006-01-01

    Loudspeakers have traditionally been designed to be as linear as possible. However, as techniques for compensating non linearities are emerging, it becomes possible to use other design criteria. This paper present and examines a new idea for improving the efficiency of loudspeakers at high levels...... by changing the voice coil layout. This deliberate non-linear design has the benefit that a smaller amplifier can be used, which has the benefit of reducing system cost as well as reducing power consumption....

  14. The Active Listening Room Simulator: Part 2

    OpenAIRE

    Naqvi, Amber; Rumsey, Francis

    2001-01-01

    This paper presents the results of computer simulation of active reflectors in a reference listening room which are used to create artificial reflections in a two speaker, stereo listening configuration. This formulates the second phase of experiments in the active listening room project involving the analysis of computer modeling results and loudspeaker selection based on free field response. The aim of this project is to create a truly variable listening condition in a reference listening r...

  15. Room acoustics computer modelling: Study of the effect of source directivity on auralizations

    DEFF Research Database (Denmark)

    Vigeant, Michelle C.; Wang, Lily M.; Rindel, Jens Holger

    2006-01-01

    auralizations made with one, four and thirteen channels, with three different instrument types and subjects rated differences in realism. An analysis of variance (ANOVA) was carried out to determine the effect of the number of channels and instrument on realism. The primary result from this study...

  16. Nonlinear Modelling of Low Frequency Loudspeakers

    DEFF Research Database (Denmark)

    Olsen, Erling Sandermann

    1997-01-01

    In the Danish LoDist project on distortion from dynamic low frequency loudspeakers a detailed nonlinear model of loudspeakers has been developed. The model has been implemented in a PC program so that it can be used to create signals for listening tests and analysis. Also, different methods...

  17. Nonlinear Modelling of Low Frequency Loudspeakers

    DEFF Research Database (Denmark)

    Olsen, Erling Sandermann

    1997-01-01

    In the Danish LoDist project on distortion from dynamic low-frequency loudspeakers, a detailed nonlinear model of loudspeakers has been developed. The model has been implemented in a PC program so that it can be used to create signals for listening tests and analysis. Also, different methods...

  18. Comparisons between Binaural In-situ Recordings and Auralizations

    DEFF Research Database (Denmark)

    Saher, Konca; Rindel, Jens Holger; Nijs, Lau

    2006-01-01

    -architectural design. This paper deals with comparison between binaural in-situ recordings and auralizations obtained from computer simulations. Listening tests and questionnaires were prepared from auralizations to compare with the reference binaural recordings. The difficulties in evaluation of auralization quality...... are discussed. The results indicate that although auralizations and binaural recordings evoke different aural perception auralization is a strong tool to assess the acoustical environment before the space is built. Two commercial programs are used for the auralizations. (ODEON and CATT-Acoustics)...

  19. A Lightweight Loudspeaker for Aircraft Communications and Active Noise Control

    Science.gov (United States)

    Warnaka, Glenn E.; Kleinle, Mark; Tsangaris, Parry; Oslac, Michael J.; Moskow, Harry J.

    1992-01-01

    A series of new, lightweight loudspeakers for use on commercial aircraft has been developed. The loudspeakers use NdFeB magnets and aluminum alloy frames to reduce the weight. The NdFeB magnet is virtually encapsulated by steel in the new speaker designs. Active noise reduction using internal loudspeakers was demonstrated to be effective in 1983. A weight, space, and cost efficient method for creating the active sound attenuating fields is to use the existing cabin loudspeakers for both communication and sound attenuation. This will require some additional loudspeaker design considerations.

  20. Analysis of design parameters for crosstalk cancellation filters applied to different loudspeaker configurations

    DEFF Research Database (Denmark)

    Parodi, Yesenia Lacouture

    2008-01-01

    Several approaches to render binaural signals through loudspeakers have been proposed previously. Some studies had focused on the optimum loudspeaker arrangement while others had proposed efficient filters. However, to our knowledge, the identification of optimal parameters for inverse methods ap...... loudspeaker arrangements. Least square approximations in frequency and time domain are evaluated along with a crosstalk canceler based on minimum-phase approximation. Filter parameters, such as length and regularization, are varied and simulated for different span and elevation angles....

  1. Frequency Dependence of Damping and Compliance in Loudspeaker Suspensions

    DEFF Research Database (Denmark)

    Thorborg, Knud; Tinggaard, Carsten; Agerkvist, Finn T.

    2010-01-01

    ]. It is an empirical model mathematically describing the effects of visco-elasticity in loudspeaker suspensions. The evaluation is to a high degree based on test loudspeakers with rubber surrounds with a high content of plasticizer combining high compliance and high damping. This is very effective to reduce rim...... resonances, but less used in high quality loudspeakers today – where “Low Loss Rubber Surround” is currently seen as a marketing feature, as it is expected to have positive impact on sound quality. The plasticized type of surround shows significant creep, followed by compliance and damping increasing towards...... - with the additives normally used to adjust stiffness and damping - neither frequency dependency of compliance nor creep are significant problems. Despite this, experience shows that frequency dependent mechanical damping nevertheless might be present. In this paper some modifications to the LOG-model are proposed...

  2. Analysis of design parameters for crosstalk cancellation filters applied to different loudspeaker configurations

    DEFF Research Database (Denmark)

    Lacouture Parodi, Yesenia; Rubak, Per

    2011-01-01

    for crosstalk cancellation filters applied to different loudspeaker configurations has not yet been addressed systematically. A study of three different inversion techniques applied to several loudspeaker arrangements is documented. Least-squares approximations in the frequency and time domains are evaluated...... along with a crosstalk canceler based on minimum-phase approximation with a frequency-independent delay. The three methods were applied to loudspeaker configurations with two channels and the least-squares approaches to configurations with four channels. Several different span angles and elevations were...

  3. Driver-Array Based Flat-Panel Loudspeakers: Theoretical Background and Design Guidelines

    Science.gov (United States)

    Anderson, David Allan

    This thesis relates to the simulation and design of flat-panel loudspeakers using moving-coil driver elements. A brief history of the industry is given, including a collection of products and patents from 1925 until the present, an overview of research papers, and a discussion of current products available. The mechanics of bending flat panels are developed with respect to localized driving forces, both in the frequency domain and the time domain as an impulse response. These simulations are compared to measurements on prototype panels. Additional resonant elements influence the behavior of the system: an optional ported rear enclosure and the resonant characteristics of the drivers. The governing equations for these systems are derived and solutions are implemented using equivalent mechanical circuits and numerical methods. The idea of using driver arrays to independently actuate modes of the panel is discussed at length with respect to modal addressability, modal spillover, and experimental validation. The numerical approach to determining the optimal driver placement for a given set of modes is derived and experimentally validated. An investigation of the acoustic behavior of flat panel loudspeakers is presented, using mechanical simulation results to predict the acoustic radiation. The simulations are compared to measurements and found to accurately predict important mechanical and acoustical behaviors. It is demonstrated that a driver array, with the proper biasing, is capable of creating a flat panel loudspeaker which acts more like a piston than a "diffuse radiator" flat panel loudspeaker. The techniques of "Modal Crossover Networks" are introduced, which use multi-band filters to bias the driver array differently for different frequency bands, optimized for audio reproduction. The question of how many drivers are necessary for a modal crossover network is addressed and found to be dependent on the estimated quality factor (Q) of the panel material and edge

  4. Nonlinear Distortion Mechanisms and Efficiency of Balanced-Armature Loudspeakers

    DEFF Research Database (Denmark)

    Jensen, Joe

    are inherently nonlinear devices, since any displacement of the loudspeaker diaphragm in- evitably changes the magnetic and electrical characteristics of the loudspeaker. Additionally, for the balanced-armature loudspeaker the signal has to be transmitted through the magnetic domain (as a magnetic B -field...... and to validate simpler equivalent circuit models. A large scale model of a balanced-armature loudspeaker has been developed and its inherent nonlinear parameters have been measured and compared to the theoretically predicted values. A measurement setup for determining the magnetic properties of soft magnetic...... materials has also been developed, since it is of great importance to understand what kind of linear and nonlinear transformations the magnetic materials impose on the signal. In hearing aid applications the power efficiency of the loudspeaker is important because every reduction in power consumption...

  5. Electroacoustical simulation of listening room acoustics for project ARCHIMEDES

    DEFF Research Database (Denmark)

    Bech, Søren

    1989-01-01

    ARCHIMEDES is a psychoacoustics research project, funded under the European EUREKA scheme. Three partners share the work involved: The Acoustics Laboratory of The Technical University of Denmark; Bang and Olufsen of Denmark; and KEF Electronics of England. Its primary object is to quantify...... the influence of listening room acoustics on the timbre of reproduced sound. For simulation of the acoustics of a standard listening room, an electroacoustic setup has been built in an anechoic chamber. The setup is based on a computer model of the listening room, and it consists of a number of loudspeakers...

  6. State-Space Modelling of Loudspeakers using Fractional Derivatives

    DEFF Research Database (Denmark)

    King, Alexander Weider; Agerkvist, Finn T.

    2015-01-01

    This work investigates the use of fractional order derivatives in modeling moving-coil loudspeakers. A fractional order state-space solution is developed, leading the way towards incorporating nonlinearities into a fractional order system. The method is used to calculate the response of a fractio......This work investigates the use of fractional order derivatives in modeling moving-coil loudspeakers. A fractional order state-space solution is developed, leading the way towards incorporating nonlinearities into a fractional order system. The method is used to calculate the response...... of a fractional harmonic oscillator, representing the mechanical part of a loudspeaker, showing the effect of the fractional derivative and its relationship to viscoelasticity. Finally, a loudspeaker model with a fractional order viscoelastic suspension and fractional order voice coil is fit to measurement data...

  7. MEMS digital parametric loudspeaker

    KAUST Repository

    Carreno, Armando Arpys Arevalo

    2016-03-23

    This paper reports on the design and fabrication of MEMS actuator arrays suitable for Digital Sound reconstruction and Parametric Directional Loudspeakers. Two distinct versions of the device were fabricated: one using the electrostatic principle actuation and the other one, the piezoelectric principle. Both versions used similar membrane dimensions, with a diameter of 500 μm. These devices are the smallest Micro-Machined Ultrasound Transducer (MUT) arrays that can be operated for both modes: Digital Sound Reconstruction and Parametric Loudspeaker. The chips consist of an array with 256 transducers, in a footprint of 12 mm by 12 mm. The total single chip size is: 2.3 cm by 2.3 cm, including the contact pads. © 2016 IEEE.

  8. MEMS digital parametric loudspeaker

    KAUST Repository

    Carreno, Armando Arpys Arevalo; Castro, David; Conchouso Gonzalez, David; Kosel, Jü rgen; Foulds, Ian G.

    2016-01-01

    This paper reports on the design and fabrication of MEMS actuator arrays suitable for Digital Sound reconstruction and Parametric Directional Loudspeakers. Two distinct versions of the device were fabricated: one using the electrostatic principle actuation and the other one, the piezoelectric principle. Both versions used similar membrane dimensions, with a diameter of 500 μm. These devices are the smallest Micro-Machined Ultrasound Transducer (MUT) arrays that can be operated for both modes: Digital Sound Reconstruction and Parametric Loudspeaker. The chips consist of an array with 256 transducers, in a footprint of 12 mm by 12 mm. The total single chip size is: 2.3 cm by 2.3 cm, including the contact pads. © 2016 IEEE.

  9. Aurally-adequate time-frequency analysis for scattered sound in auditoria

    Science.gov (United States)

    Norris, Molly K.; Xiang, Ning; Kleiner, Mendel

    2005-04-01

    The goal of this work was to apply an aurally-adequate time-frequency analysis technique to the analysis of sound scattering effects in auditoria. Time-frequency representations were developed as a motivated effort that takes into account binaural hearing, with a specific implementation of interaural cross-correlation process. A model of the human auditory system was implemented in the MATLAB platform based on two previous models [A. Härmä and K. Palomäki, HUTear, Espoo, Finland; and M. A. Akeroyd, A. Binaural Cross-correlogram Toolbox for MATLAB (2001), University of Sussex, Brighton]. These stages include proper frequency selectivity, the conversion of the mechanical motion of the basilar membrane to neural impulses, and binaural hearing effects. The model was then used in the analysis of room impulse responses with varying scattering characteristics. This paper discusses the analysis results using simulated and measured room impulse responses. [Work supported by the Frank H. and Eva B. Buck Foundation.

  10. A Compact and Low-Cost MEMS Loudspeaker for Digital Hearing Aids.

    Science.gov (United States)

    Sang-Soo Je; Rivas, F; Diaz, R E; Jiuk Kwon; Jeonghwan Kim; Bakkaloglu, B; Kiaei, S; Junseok Chae

    2009-10-01

    A microelectromechanical-systems (MEMS)-based electromagnetically actuated loudspeaker to reduce form factor, cost, and power consumption, and increase energy efficiency in hearing-aid applications is presented. The MEMS loudspeaker has multilayer copper coils, an NiFe soft magnet on a thin polyimide diaphragm, and an NdFeB permanent magnet on the perimeter. The coil impedance is measured at 1.5 Omega, and the resonant frequency of the diaphragm is located far from the audio frequency range. The device is driven by a power-scalable, 0.25-mum complementary metal-oxide semiconductor class-D SigmaDelta amplifier stage. The class-D amplifier is formed by a differential H-bridge driven by a single bit, pulse-density-modulated SigmaDelta bitstream at a 1.2-MHz clock rate. The fabricated MEMS loudspeaker generates more than 0.8-mum displacement, equivalent to 106-dB sound pressure level (SPL), with 0.13-mW power consumption. Driven by the SigmaDelta class-D amplifier, the MEMS loudspeaker achieves measured 65-dB total harmonic distortion (THD) with a measurement uncertainty of less than 10%. Energy-efficient and cost-effective advanced hearing aids would benefit from further miniaturization via MEMS technology. The results from this study appear very promising for developing a compact, mass-producible, low-power loudspeaker with sufficient sound generation for hearing-aid applications.

  11. Influence of visual appearance on loudspeaker sound quality evaluation

    DEFF Research Database (Denmark)

    Karandreas, Theodoros-Alexandros; Christensen, Flemming

    2008-01-01

    Product sound quality evaluation aims to identify relevant attributes and assess their influence on the overall auditory impression. Extending this sound specific rationale, the present study evaluates overall impression in relation to audition and vision, specifically for loudspeakers. In order...... to quantify the bias that the loudspeaker appearance has on the sound quality evaluation of a naive listening panel, audio stimuli of varied degradation are coupled with actual loudspeakers of different visual appearance....

  12. Real-time Loudspeaker Distance Estimation with Stereo Audio

    DEFF Research Database (Denmark)

    Nielsen, Jesper Kjær; Gaubitch, Nikolay; Heusdens, Richard

    2015-01-01

    Knowledge on how a number of loudspeakers are positioned relative to a listening position can be used to enhance the listening experience. Usually, these loudspeaker positions are estimated using calibration signals, either audible or psycho-acoustically hidden inside the desired audio signal...

  13. Influence of visual stimuli on the sound quality evaluation of loudspeaker systems

    DEFF Research Database (Denmark)

    Karandreas, Theodoros-Alexandros; Christensen, Flemming

    Product sound quality evaluation aims to identify relevant attributes and assess their influence on the overall auditory impression. Extending this sound specific rationale, the present study evaluates overall impression in relation to hearing and vision, specifically for loudspeakers. In order...... to quantify the bias that the image of a loudspeaker has on the sound quality evaluation of a naive listening panel, loudspeaker sounds of varied degradation are coupled with positively or negatively biasing visual input of actual loudspeakers, and in a separate experiment by pictures of the same loudspeakers....

  14. Towards Predicting Room Acoustical Effects on Sound-Field ASSR from Stimulus Modulation Power

    DEFF Research Database (Denmark)

    Zapata Rodriguez, Valentina; Laugesen, Søren; Jeong, Cheol-Ho

    ) is considered. Instead of using insert earphones to deliver the stimuli, as is customary, the auditory signals are reproduced from a loudspeaker placed in front of the subject, so as to include the hearing aid in the transmission path. Loudspeaker presentation of the stimulus can lower its effective modulation...... properties of the measurement room has not been considered. The present work explores the relation between the stimulus modulation power and the ASSR amplitude in a simulated sound-field ASSR data set with varying reverberation time. Three rooms were simulated using the Green's function approach...

  15. A Study of the Creep Effect in Loudspeaker Suspension

    DEFF Research Database (Denmark)

    Agerkvist, Finn T.; Thorborg, Knud; Tinggaard, Carsten

    2008-01-01

    This paper investigates the creep effect, the visco elastic behaviour of loudspeaker suspension parts, which can be observed as an increase in displacement far below the resonance frequency. The creep effect means that the suspension cannot be modelled as a simple spring. The need for an accurate...... creep model is even larger as the validity of loudspeaker models are now sought extended far into the nonlinear domain of the loudspeaker. Different creep models are investigated and implemented both in simple lumped parameter models as well as time domain non-linear models, the simulation results...

  16. Real-time loudspeaker distance estimation with stereo audio

    DEFF Research Database (Denmark)

    2017-01-01

    , using a first microphone arranged adjacent to the first loudspeaker, and acquiring a second recorded signal vector x2 from a second microphone arranged adjacent to the second loudspeaker, wherein x1 and x2 are N-dimensional vectors, setting the distance equal to ηv/f, where v is the speed of sound, f...

  17. Performance Analysis of Digital loudspeaker Arrays

    DEFF Research Database (Denmark)

    Pedersen, Bo Rohde; Kontomichos, Fotios; Mourjopoulos, John

    2008-01-01

    An analysis of digital loudspeaker arrays shows that the ways in which bits are mapped to the drivers influence the quality of the audio result. Specifically, a "bit-summed" rather than the traditional "bit-mapped" strategy greatly reduces the number of times drivers make binary transitions per...... period of the input frequency. Detailed simulations compare the results for a 32-loudspeaker array with a similar configuration with analog excitation of the drivers. Ideally, drivers in digital arrays should be very small and span a small area, but that sets limits on the low-frequency response...

  18. Effects of secondary loudspeaker properties on broadband feedforward active duct noise control.

    Science.gov (United States)

    Chan, Yum-Ji; Huang, Lixi; Lam, James

    2013-07-01

    Dependence of the performance of feedforward active duct noise control on secondary loudspeaker parameters is investigated. Noise reduction performance can be improved if the force factor of the secondary loudspeaker is higher. For example, broadband noise reduction improvement up to 1.6 dB is predicted by increasing the force factor by 50%. In addition, a secondary loudspeaker with a larger force factor was found to have quicker convergence in the adaptive algorithm in experiment. In simulations, noise reduction is improved in using an adaptive algorithm by using a secondary loudspeaker with a heavier moving mass. It is predicted that an extra broadband noise reduction of more than 7 dB can be gained using an adaptive filter if the force factor, moving mass and coil inductance of a commercially available loudspeaker are doubled. Methods to increase the force factor beyond those of commercially available loudspeakers are proposed.

  19. Differences in directional sound source behavior and perception between assorted computer room models

    DEFF Research Database (Denmark)

    Vigeant, Michelle C.; Wang, Lily M.; Rindel, Jens Holger

    2004-01-01

    considering reverberation time. However, for the three other parameters evaluated (sound pressure level, clarity index and lateral fraction), the changing diffusivity of the room does not diminish the importance of the directivity. The study therefore shows the importance of considering source directivity......Source directivity is an important input variable when using room acoustic computer modeling programs to generate auralizations. Previous research has shown that using a multichannel anechoic recording can produce a more natural sounding auralization, particularly as the number of channels...

  20. Differences in directional sound source behavior and perception between assorted computer room models

    DEFF Research Database (Denmark)

    Vigeant, M. C.; Wang, L. M.; Rindel, Jens Holger

    2004-01-01

    time. However, for the three other parameters evaluated (sound-pressure level, clarity index, and lateral fraction), the changing diffusivity of the room does not diminish the importance of the directivity. The study therefore shows the importance of considering source directivity when using computer......Source directivity is an important input variable when using room acoustic computer modeling programs to generate auralizations. Previous research has shown that using a multichannel anechoic recording can produce a more natural sounding auralization, particularly as the number of channels...

  1. Auralizations with loudspeaker arrays from a phased combination of the image source method and acoustical radiosity

    DEFF Research Database (Denmark)

    Marbjerg, Gerd Høy; Brunskog, Jonas; Jeong, Cheol-Ho

    2017-01-01

    In order to create a simulation tool that is well-suited for small rooms with low diffusion and highly absorbing ceilings, a new room acoustic simulation tool has been developed that combines a phased version of the image source with acoustical radiosity and that considers the angle dependence...... of the PARISM impulse response, because more directional information is available with acoustical radiosity. Small rooms with absorbing surfaces are tested, because this is the room type that PARISM is particularly useful for....

  2. Analysis of nonlinear behavior of loudspeakers using the instantaneous frequency

    DEFF Research Database (Denmark)

    Huang, Hai; Jacobsen, Finn

    2003-01-01

    on the Fourier transform. In this work, a new method using the instantaneous frequency is introduced for describing and characterizing loudspeaker nonlinearities. First, numerical integration is applied to simulate the nonlinearities of loudspeakers caused by two nonlinear parameters, force factor and stiffness...

  3. Optimization of Loudspeaker Part Design Parameters by Air Viscosity Damping Effect

    OpenAIRE

    Yue Hu; Xilu Zhao; Takao Yamaguchi; Manabu Sasajima; Yoshio Koike; Akira Hara

    2016-01-01

    This study optimized the design parameters of a cone loudspeaker as an example of high flexibility of the product design. We developed an acoustic analysis software program that considers the impact of damping caused by air viscosity. In sound reproduction, it is difficult to optimize each parameter of the loudspeaker design. To overcome the limitation of the design problem in practice, this study presents an acoustic analysis algorithm to optimize the design parameters of the loudspeaker. Th...

  4. Active low frequency sound field control in a listening room using CABS (Controlled Acoustic Bass System) will also reduce the sound transmitted to neighbour rooms

    DEFF Research Database (Denmark)

    Nielsen, Sofus Birkedal; Celestinos, Adrian

    2012-01-01

    Sound in rooms and transmission of sound between rooms gives the biggest problems at low frequencies. Rooms with rectangular boundaries have strong resonance frequencies and will give big spatial variations in sound pressure level (SPL) in the source room, and an increase in SPL of 20 dB at a wall...... Bass System) is a time based room correction system for reproduced sound using loudspeakers. The system can remove room modes at low frequencies, by active cancelling the reflection from at the rear wall to a normal stereo setup. Measurements in a source room using CABS and in two neighbour rooms have...... shown a reduction in sound transmission of up to 10 dB at resonance frequencies and a reduction at broadband noise of 3 – 5 dB at frequencies up to 100 Hz. The ideas and understanding of the CABS system will also be given....

  5. Low frequency sound field control in rectangular listening rooms using CABS (Controlled Acoustic Bass System) will also reduce sound transmission to neighbor rooms

    DEFF Research Database (Denmark)

    Nielsen, Sofus Birkedal; Celestinos, Adrian

    2011-01-01

    Sound reproduction is often taking place in small and medium sized rectangular rooms. As rectangular rooms have 3 pairs of parallel walls the reflections at especially low frequencies will cause up to 30 dB spatial variations of the sound pressure level in the room. This will take place not only...... at resonance frequencies, but more or less at all frequencies. A time based room correction system named CABS (Controlled Acoustic Bass System) has been developed and is able to create a homogeneous sound field in the whole room at low frequencies by proper placement of multiple loudspeakers. A normal setup...... from the rear wall, and thereby leaving only the plane wave in the room. With a room size of (7.8 x 4.1 x 2.8) m. it is possible to prevent modal frequencies up to 100 Hz. An investigation has shown that the sound transmitted to a neighbour room also will be reduced if CABS is used. The principle...

  6. Shift of the Acoustic Center of a Closed-Box Loudspeaker in a Linear Array: Investigation Using the Beamforming Technique

    DEFF Research Database (Denmark)

    Chang, Ji-Ho; Jensen, Joe; Agerkvist, Finn T.

    2015-01-01

    The center of the spherical waves radiated from a loudspeaker is defined as its acoustic center. This study aims to investigate how the acoustic center of a closed-box loudspeaker is shifted when the loudspeaker is placed in a linear array. That is, the acoustic center of the loudspeaker is estim......The center of the spherical waves radiated from a loudspeaker is defined as its acoustic center. This study aims to investigate how the acoustic center of a closed-box loudspeaker is shifted when the loudspeaker is placed in a linear array. That is, the acoustic center of the loudspeaker...... is estimated when the loudspeaker is placed alone and then the loudspeaker is placed in a linear array composed of two or three identical loudspeakers. The acoustic center of each loudspeaker in the linear arrays is estimated with the other loudspeakers turned off and compared with that in the single...... that the acoustic center is shifted differently depending on the relative position of the loudspeaker in the array. This implies that the performance of sound field control with a linear array of loudspeakers can be improved by taking the shift of the acoustic center into account....

  7. Sound therapy and aural rehabilitation for tinnitus: a person centred therapy framework based on an ecological model of tinnitus.

    Science.gov (United States)

    Searchfield, Grant D; Linford, Tania; Durai, Mithila

    2018-03-23

    Tinnitus is a common oto-neurological complaint often accompanying hearing loss. In this perspective on rehabilitation we describe a framework for sound therapy and aural rehabilitation of tinnitus based on the ecological model of tinnitus. A thematic network analysis-based approach was used to relate aural rehabilitation methods to the ecological model of tinnitus and the client-oriented scale of improvement in tinnitus. Aural rehabilitation methods were mapped to concepts of: (1) Context, (2) presence of sound and (3) reaction to sound. A global theme was: adaptation to sound. The framework is the result of an iterative and cumulative research program exploring tinnitus as the outcome of the relationship between individual psychoacoustics and psychosocial factors including context of perception. The intent of this framework is to help guide audiologists managing tinnitus. The framework has been useful in our clinic as illustrated by a case study. The benefits of this approach relative to standard care needs to be independently ascertained. Implications for Rehabilitation Tinnitus is a common oto-neurological complaint that when severe can be very disabling. Tinnitus is very heterogeneous as a consequence of this no one treatment is suitable for everyone. The sound therapy and aural rehabilitation for tinnitus framework is designed to assist audiologists in clinical planning that addresses individual needs. The framework is the result of an iterative and cumulative research program exploring tinnitus as the outcome of the relationship between individual psychoacoustics and psychosocial factors including context of perception.

  8. A loudspeaker-based room auralisation (LoRA) system for auditory perception research

    DEFF Research Database (Denmark)

    Buchholz, Jörg; Favrot, Sylvain Emmanuel

    Most research on understanding the signal processing of the auditory system has been realized in anechoic or almost anechoic environments. The knowledge derived from these experiments cannot be directly transferred to reverberant environments. In order to investigate the auditory signal processing...... are utilized to realise highly authentic room reverberation. This system aims at providing a flexible research platform for conducting auditory experiments with normal-hearing, hearing-impaired, and aided hearing-impaired listeners in a fully controlled and realistic environment. An overall description...

  9. Objective evaluation of the sweet spot size in spatial sound reproduction using elevated loudspeakers

    DEFF Research Database (Denmark)

    Lacouture Parodi, Yesenia; Rubak, Per

    2010-01-01

    to the loudspeakers. This paper presents a follow-up evaluation of the performance of the three inversion techniques when the above mentioned conditions are relaxed. A setup to measure the sweet spot of different loudspeaker arrangements is described. The sweet spot was measured for 21 different loudspeaker...

  10. Construction of Lightweight Loudspeaker Enclosures

    DEFF Research Database (Denmark)

    Juul-Nyholm, Herle Bagh; Severinsen, Jonas Corfitz; Schneider, Henrik

    2017-01-01

    On the basis of bass cabinets, this paper deals with the problem of reducing loudspeaker enclosure weight. An introductory market analysis emphasizes that lighter cabinets are sought, but maintenance of sound quality is vital. The problem is challenged through experiments and simulations in COMSO...

  11. Measurements of earplug attenuation under supra-aural and circumaural headphones.

    Science.gov (United States)

    Tufts, Jennifer B; Palmer, Jillian V; Marshall, Lynne

    2012-10-01

    Supra-aural audiometric headphones are generally not recommended for use in measuring the attenuation of earplugs, because contact between the headphone and pinna and/or earplug could alter the attenuation obtained, and because of concerns of non-comparability between modes of excitation from supra-aural headphones and the sound-field procedure required by the standardized method. In this study, we compared measurements of earplug attenuation obtained under Telephonics TDH-50P supra-aural headphones with measurements obtained under circumaural headphones designed expressly for such testing. The attenuation of three types of earplugs (foam, premolded quadruple-flange, and custom-molded) was measured in a repeated-measures design. The study sample comprised 42 normal-hearing adults (21 females, 21 males). With the foam earplugs, nearly all of the attenuation measurements under the supra-aural headphones fell within 10 dB of the measurements under the circumaural headphones. With the flange and custom earplugs, approximately 10% of individuals obtained spuriously high attenuation under the supra-aural headphones. We conclude that standard supra-aural audiometric headphones are suitable for measuring the attenuation provided by foam earplugs. However, supra-aural headphones should not be used to measure the attenuation of flange or custom-molded earplugs. The potential exists for substantial over-estimation of attenuation, especially of custom plugs.

  12. Experimental implementation of a low-frequency global sound equalization method based on free field propagation

    DEFF Research Database (Denmark)

    Santillan, Arturo Orozco; Pedersen, Christian Sejer; Lydolf, Morten

    2007-01-01

    An experimental implementation of a global sound equalization method in a rectangular room using active control is described in this paper. The main purpose of the work has been to provide experimental evidence that sound can be equalized in a continuous three-dimensional region, the listening zone......, which occupies a considerable part of the complete volume of the room. The equalization method, based on the simulation of a progressive plane wave, was implemented in a room with inner dimensions of 2.70 m x 2.74 m x 2.40 m. With this method,the sound was reproduced by a matrix of 4 x 5 loudspeakers...... in one of the walls. After traveling through the room, the sound wave was absorbed on the opposite wall, which had a similar arrangement of loudspeakers, by means of active control. A set of 40 digital FIR filters was used to modify the original input signal before it was fed to the loudspeakers, one...

  13. An approach to global equalisation in a rectangular room at low frequencies

    DEFF Research Database (Denmark)

    Orozco, Arturo

    1999-01-01

    The motivation of this study is the fact that sound reproduced in a room undergoes a spectral colouration, which is undesirable. This effect is particularly severe at low frequencies in small enclosures.A theoretical study based on computer simulations is presented. The listening area is a contin......The motivation of this study is the fact that sound reproduced in a room undergoes a spectral colouration, which is undesirable. This effect is particularly severe at low frequencies in small enclosures.A theoretical study based on computer simulations is presented. The listening area...... is a continuous region in a rectangular room that occupies almost the entire room. A travelling wave is generated by feeding a number of loudspeakes with the signal to be reproduced passed through digital filters. The problem of designing these filters is investigated both in the frequency domain and in the time...

  14. How to Teach Aural English More Effectively

    Science.gov (United States)

    Huang, Huan

    2009-01-01

    As a means of communication, listening plays an important role in people's life. In a foreign language classroom, listening comprehension has never drawn the same attention of educators as it now does. So it is a vital importance to teach aural English more effectively. In view of present situation of aural English teaching and wrong ideas about…

  15. Initial Development of a Quadcopter Simulation Environment for Auralization

    Science.gov (United States)

    Christian, Andrew; Lawrence, Joseph

    2016-01-01

    This paper describes a recently created computer simulation of quadcopter flight dynamics for the NASA DELIVER project. The goal of this effort is to produce a simulation that includes a number of physical effects that are not usually found in other dynamics simulations (e.g., those used for flight controller development). These effects will be shown to have a significant impact on the fidelity of auralizations - entirely synthetic time-domain predictions of sound - based on this simulation when compared to a recording. High-fidelity auralizations are an important precursor to human subject tests that seek to understand the impact of vehicle configurations on noise and annoyance.

  16. Influence of visual stimuli in the sound quality evaluation of loudspeaker systems

    DEFF Research Database (Denmark)

    Karandreas, Theodoros-Alexandros; Christensen, Flemming

    2006-01-01

    There is currently an increasing demand to evaluate sound quality attributes of products and understand to what extend they influence a user's overall impression, since there is usually more than one modality stimulating this evaluation. The present study uses the loudspeakers as an example...... and evaluates the overall impression in relation to hearing and vision.In order to quantify the bias that the image of a loudspeaker has on the sound quality evaluation done by a naive listening panel, loudspeaker sounds of varied degradation are coupled with positively or negatively biasing visual input...

  17. Time varying behaviour of the loudspeaker suspension

    DEFF Research Database (Denmark)

    Agerkvist, Finn; Pedersen, Bo Rohde

    2009-01-01

    The compliance of the loudspeaker suspension is known to depend on the recent excitation level history. Previous investigations have shown that the electrical power as well as displacement and velocity plays a role. In this paper the hypothesis that the changes in compliance are caused mainly...... by how much the suspension has been stretched, i.e., the maximum displacement, is investigated. For this purpose the changes in compliance are measured when exposing the loudspeaker to different levels and types of electrical excitation signals, as well as mechanical excitation only. For sinusoidal...... excitation the change in compliance is shown to depend primarily on maximum displacement. But for square pulse excitation the duration of the excitation also plays an important role....

  18. Physical modeling and characterization of thermo-acoustic loudspeakers made of silver nano-wire films

    Science.gov (United States)

    La Torraca, P.; Larcher, L.; Bobinger, M.; Pavan, P.; Seeber, B.; Lugli, P.

    2017-06-01

    Recent developments of ultra-low heat capacity nanostructured materials revived the interest in the thermo-acoustic (TA) loudspeaker technology, which shows important advantages compared to the classical dynamic loudspeakers as they feature a lower cost and weight, flexibility, conformability to the surface of various shapes, and transparency. The development of the TA loudspeaker technology requires accurate physical models connecting the material properties to the thermal and acoustic speaker's performance. We present here a combined theoretical and experimental analysis of TA loudspeakers, where the electro-thermal and the thermo-acoustic transductions are handled separately, thus allowing an in-depth description of both the pressure and temperature dynamics. The electro-thermal transduction is analyzed by accounting for all the heat flow processes taking place between the TA loudspeaker and the surrounding environment, with focus on their frequency dependence. The thermo-acoustic conversion is studied by solving the coupled thermo-acoustic equations, derived from the Navier-Stokes equations, and by exploiting the Huygens-Fresnel principle to decompose the TA loudspeaker surface into a dense set of TA point sources. A general formulation of the 3D pressure field is derived summing up the TA point source contributions via a Rayleigh integral. The model is validated against temperature and sound pressure level measured on the TA loudspeaker sample made of a Silver Nanowire random network deposited on a polyimide substrate. A good agreement is found between measurements and simulations, demonstrating that the model is capable of connecting material properties to the thermo-acoustic performance of the device, thus providing a valuable tool for the design and optimization of TA loudspeakers.

  19. Auralization of an orchestra using multichannel and multisource technique (A)

    DEFF Research Database (Denmark)

    Vigeant, Michelle C.; Wang, Lily M.; Rindel, Jens Holger

    2006-01-01

    Previous work has shown the importance of including source directivity in computer modeling for auralizations. A newer method to capture source directivity in auralizations is the multichannel technique, which uses multichannel anechoic recordings. In this study, five-channel anechoic recordings ...... made with a single channel orchestral anechoic recording using (ii) a surface source and (iii) a single omni-directional source. [Work supported by the National Science Foundation.]......Previous work has shown the importance of including source directivity in computer modeling for auralizations. A newer method to capture source directivity in auralizations is the multichannel technique, which uses multichannel anechoic recordings. In this study, five-channel anechoic recordings...... were obtained for every orchestral part of two symphonies at the Technical University of Denmark. Five-channel auralizations were then created for each instrument, located at its typical position on-stage in a concert hall, by convolving five impulse responses from sources that each represent...

  20. Sound Radiation from a Loudspeaker Cabinet using the Boundary Element Method

    DEFF Research Database (Denmark)

    Fernandez Grande, Efren

    had been reported, based on subjective testing. This study aims to detect the reported problem. The radiation from the cabinet is calculated using the Boundary Element Method. The analysis examines both the frequency domain and the time domain characteristics (in other words, the steady state response......, in some cases becoming clearly audible. The aim of this study is to provide a tool that can evaluate the contribution from the cabinet to the overall sound radiated by a loudspeaker. The specific case of a B&O Beolab 9 early prototype has been investigated. An influence by the cabinet of this prototype...... and the impulse response) of the loudspeaker and the cabinet. A significant influence of the cabinet has been detected, which becomes especially apparent in the time domain, during the sound decay process....

  1. Sound radiation from a loudspeaker, from a spherical pole cap, and from a piston in an infinite baffle

    NARCIS (Netherlands)

    Aarts, R.M.; Janssen, A.J.E.M.

    2011-01-01

    Loudspeakers are often modelled as a rigid piston in an infinite baffle. This model is for real loudspeakers somewhat limited in two ways. One issue is that a loudspeaker is not rigid and a second issue is that a loudspeaker is mostly used in a cabinet. Both issues are addressed here by developing

  2. Sound radiation from a loudspeaker, from a spherical pole cap, and from a piston in an infinite baffle

    NARCIS (Netherlands)

    Aarts, R.M.; Janssen, A.J.E.M.

    2012-01-01

    Loudspeakers are often modelled as a rigid piston in an infinite baffle. As a model for real loudspeakers, this approach is limited in two ways. One issue is that a loudspeaker cone is not rigid, and a second issue is that a loudspeaker is mostly used in a cabinet. Both issues are addressed here by

  3. The technology of binaural listening

    CERN Document Server

    2013-01-01

    This book reports on the application of advanced models of the human binaural hearing system in modern technology, among others, in the following areas:  binaural analysis of aural scenes, binaural de-reverberation, binaural quality assessment of audio channels, loudspeakers and performance spaces, binaural perceptual coding, binaural processing in hearing aids and cochlea implants, binaural systems in robots, binaural/tactile human-machine interfaces, speech-intelligibility prediction in rooms and/or multi-speaker scenarios. An introduction to binaural modeling and an outlook to the future are provided. Further, the book features a MATLAB toolbox to enable readers to construct their own dedicated binaural models on demand.

  4. The effect of scattering on sound field control with a circular double-layer array of loudspeakers

    DEFF Research Database (Denmark)

    Chang, Jiho; Jacobsen, Finn

    2012-01-01

    A recent study has shown that a circular double-layer array of loudspeakers makes it possible to achieve a sound field control that can generate a controlled field inside the array and reduce sound waves propagating outside the array. This is useful if it is desirable not to disturb people outside...... the array or to prevent the effect of reflections from the room. The study assumed free field condition, however in practice a listener will be located inside the array. The listener scatters sound waves, which propagate outward. Consequently, the scattering effect can be expected to degrade the performance...

  5. Mobile Learning: Using Application "Auralbook" to Learn Aural Skills

    Science.gov (United States)

    Chen, Chi Wai Jason

    2015-01-01

    This study is to investigate the effectiveness of using mobile devices such as iPhone/iPad/android phone/tablet to facilitate mobile learning in aural skills. The application "Auralbook" was designed in 2011 by an engineer/musician to use mobile devices to learn aural skills. This application enables students to sing, record, clap and…

  6. Magnetic flux generator for balanced membrane loudspeaker

    DEFF Research Database (Denmark)

    Rehder, Jörg; Rombach, Pirmin; Hansen, Ole

    2002-01-01

    This paper reports the development of a magnetic flux generator with an application in a hearing aid loudspeaker produced in microsystem technology (MST). The technology plans for two different designs for the magnetic flux generator utilizing a softmagnetic substrate or electroplated Ni...

  7. Technologic advances in aural rehabilitation: applications and innovative methods of service delivery.

    Science.gov (United States)

    Sweetow, Robert W; Sabes, Jennifer Henderson

    2007-06-01

    The level of interest in aural rehabilitation has increased recently, both in clinical use and in research presentations and publications. Advances in aural rehabilitation have seen previous techniques such as speech tracking and analytic auditory training reappear in computerized forms. These new delivery methods allow for a consistent, cost-effective, and convenient training program. Several computerized aural rehabilitation programs for hearing aid wearers and cochlear implant recipients have recently been developed and were reported on at the 2006 State of the Science Conference of the Rehabilitation Engineering Research Center on Hearing Enhancement at Gallaudet University. This article reviews these programs and outlines the similarities and differences in their design. Another promising area of aural rehabilitation research is the use of pharmaceuticals in the rehabilitation process. The results from a study of the effect of d-amphetamine in conjunction with intensive aural rehabilitation with cochlear implant patients are also described.

  8. Audible reflection density for different late reflection criteria in rooms

    DEFF Research Database (Denmark)

    Krueger, Donata; Jeong, Cheol-Ho; Brunskog, Jonas

    2012-01-01

    For reasonably accurate but practical auralizations, some simplifications and approximations are needed. The main issue in the present investigation is that the reflection density of a room impulse response, in theory, increases so fast as a quadratic function of the elapsed time, even assuming...

  9. A theoretical study on directivity control of multiple-loudspeaker system with a quadrupole radiation pattern in low frequency range

    Science.gov (United States)

    Irwansyah, Kuse, Naoyuki; Usagawa, Tsuyoshi

    2017-08-01

    Directivity pattern of an ordinary loudspeaker becomes more directive at higher frequencies. However, because a single loudspeaker tends to radiate uniformly in all directions at low frequencies, reverberation from surrounding building walls may affect speech intelligibility when installing a multiple-loudspeaker system at crossroads. As an alternative, a sharply directive sound source is recommended to be used, but in many cases the directivity of an ordinary loudspeaker is less sharp at lower frequencies. Therefore, in order to overcome such a limitation, this paper discusses the possibility of using four loudspeakers under active control to realize a quadrupole radiation pattern in low frequency range. In this study, the radiation pattern of a primary loudspeaker and three secondary loudspeakers has been modelled. By placing the loudspeakers close together in the direction of 0°, 90°, 180°, and 270°, it was theoretically demonstrated that a quadrupole radiation pattern can be shaped in the target frequency range up to 600 Hz by simply controlling the directivity in three of four directions which are 45°, 135°, 225°, and 315°. Although, the radiation pattern model is far from realistic configurations and conditions, it is possible to realize a quadrupole radiation pattern in the low frequency range.

  10. 47 CFR 73.665 - Use of TV aural baseband subcarriers.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Use of TV aural baseband subcarriers. 73.665... RADIO BROADCAST SERVICES Television Broadcast Stations § 73.665 Use of TV aural baseband subcarriers. Licensees of TV broadcast stations may transmit, without further authorization from the FCC, subcarriers and...

  11. Modelling Loudspeaker Non-Linearities

    DEFF Research Database (Denmark)

    Agerkvist, Finn T.

    2007-01-01

    This paper investigates different techniques for modelling the non-linear parameters of the electrodynamic loudspeaker. The methods are tested not only for their accuracy within the range of original data, but also for the ability to work reasonable outside that range, and it is demonstrated...... that polynomial expansions are rather poor at this, whereas an inverse polynomial expansion or localized fitting functions such as the gaussian are better suited for modelling the Bl-factor and compliance. For the inductance the sigmoid function is shown to give very good results. Finally the time varying...

  12. Modelling the Perceptual Components of Loudspeaker Distortion

    DEFF Research Database (Denmark)

    Olsen, Sune L.; Agerkvist, Finn T.; MacDonald, Ewen

    2016-01-01

    While non-linear distortion in loudspeakers decreases audio quality, the perceptual consequences can vary substantially. This paper investigates the metric Rnonlin [1] which was developed to predict subjective measurements of sound quality in nonlinear systems. The generalisability of the metric...... the perceptual consequences of non-linear distortion....

  13. Experimental validation of sound field control with a circular double-layer array of loudspeakers

    DEFF Research Database (Denmark)

    Chang, Jiho; Jacobsen, Finn

    2013-01-01

    This paper is concerned with experimental validation of a recently proposed method of controlling sound fields with a circular double-layer array of loudspeakers [Chang and Jacobsen, J. Acoust. Soc. Am. 131(6), 4518-4525 (2012)]. The double-layer of loudspeakers is realized with 20 pairs of closed...

  14. Effects of incongruent auditory and visual room-related cues on sound externalization

    DEFF Research Database (Denmark)

    Carvajal, Juan Camilo Gil; Santurette, Sébastien; Cubick, Jens

    Sounds presented via headphones are typically perceived inside the head. However, the illusion of a sound source located out in space away from the listener’s head can be generated with binaural headphone-based auralization systems by convolving anechoic sound signals with a binaural room impulse...... response (BRIR) measured with miniature microphones placed in the listener’s ear canals. Sound externalization of such virtual sounds can be very convincing and robust but there have been reports that the illusion might break down when the listening environment differs from the room in which the BRIRs were...... recorded [1,2,3]. This may be due to incongruent auditory cues between the recording and playback room during sound reproduction [2]. Alternatively, an expectation effect caused by the visual impression of the room may affect the position of the perceived auditory image [3]. Here, we systematically...

  15. Improving Aural Skills within the Curriculum: A Literature Review

    Science.gov (United States)

    Barlow, Sarah

    2016-01-01

    Success in music theory studies appears to be simply a matter of learning the rules and applying them. This is not the case with aural skills, which include labelling a scale played on piano, or writing a rhythm heard on a drum. Student success in aural tasks is not always consistent, and the student skill seems to fade over time if there is no…

  16. 46 CFR 113.50-15 - Loudspeakers.

    Science.gov (United States)

    2010-10-01

    ... loudspeakers must be watertight and suitably protected from the effects of the wind and seas. (c) There must be... emergency announcements must be— (1) In interior spaces, 75 dB(A) or, if the background noise level exceeds 75 dB(A), then at least 20 dB(A) above maximum background noise level; and (2) In exterior spaces, 80...

  17. Controlled Acoustic Bass System (CABS) A Method to Achieve Uniform Sound Field Distribution at Low Frequencies in Rectangular Rooms

    DEFF Research Database (Denmark)

    Celestinos, Adrian; Nielsen, Sofus Birkedal

    2008-01-01

    The sound field produced by loudspeakers at low frequencies in small- and medium-size rectangular listening rooms is highly nonuniform due to the multiple reflections and diffractions of sound on the walls and different objects in the room. A new method, called controlled acoustic bass system (CA......-frequency range. CABS has been simulated and measured in two different standard listening rooms with satisfactory results....

  18. 47 CFR 73.653 - Operation of TV aural and visual transmitters.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Operation of TV aural and visual transmitters. 73.653 Section 73.653 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES Television Broadcast Stations § 73.653 Operation of TV aural and visual...

  19. Requirements Specication for Ampliers and Power Supplies in Active Loudspeakers

    DEFF Research Database (Denmark)

    Schneider, Henrik; Jensen, Lasse Crone; Petersen, Lars Press

    2014-01-01

    This work aims to provide designers with a method to develop a requirements specication for power supplies and ampliers in active loudspeakers. The motivation is to avoid over-sizing and unnecessary cost. A realistic estimation of the power supplied during playback of audio in a given loudspeaker...... is obtained by considering a wide range of audio source material, loudness normalization of the source material, crossover ltering, driver characteristics as well as a perceived maximum loudness/volume level. The results from analysing a sub-woofer and a woofer reveals the peak power, peak voltage, peak...... current and apparent power - thus providing a solid foundation for a requirement specication....

  20. Practical considerations for integrating switch mode audio amplifiers and loudspeakers for a higher power efficiency

    DEFF Research Database (Denmark)

    Poulsen, Søren; Andersen, Michael Andreas E.

    2004-01-01

    An integration of electrodynamic loudspeakers and switch mode amplifiers has earlier been proposed in [1]. The work presented in this paper is related to the practical aspects of integration of switch mode audio amplifiers and electro dynamic loudspeakers, using the speaker’s voice coil as output...

  1. Multichannel active control of random noise in a small reverberant room

    DEFF Research Database (Denmark)

    Laugesen, Søren; Elliott, Stephen J.

    1993-01-01

    An algorithm for multichannel adaptive IIR (infinite impulse response) filtering is presented and applied to the active control of broadband random noise in a small reverberant room. Assuming complete knowledge of the primary noise, the theoretically optimal reductions of acoustic energy are init...... with the primary noise field generated by a panel excited by a loudspeaker in an adjoining room. These results show that far better performances are provided by IIR and FIR filters when the primary source has a lightly damped dynamic behavior which the active controller must model...

  2. Validation of Power Requirement Model for Active Loudspeakers

    DEFF Research Database (Denmark)

    Schneider, Henrik; Madsen, Anders Normann; Bjerregaard, Ruben

    2015-01-01

    . There are however many advantages that could be harvested from such knowledge like size, cost and efficiency improvements. In this paper a recently proposed power requirement model for active loudspeakers is experimentally validated and the model is expanded to include the closed and vented type enclosures...

  3. Optimization of orthotropic distributed-mode loudspeaker using attached masses and multi-exciters.

    Science.gov (United States)

    Lu, Guochao; Shen, Yong; Liu, Ziyun

    2012-02-01

    Based on the orthotropic model of the plate, the method to optimize the sound response of the distributed-mode loudspeaker (DML) using the attached masses and the multi-exciters has been investigated. The attached masses method will rebuild the modes distribution of the plate, based on which multi-exciter method will smooth the sound response. The results indicate that the method can be used to optimize the sound response of the DML. © 2012 Acoustical Society of America

  4. Spherical loudspeaker array for local active control of sound.

    Science.gov (United States)

    Rafaely, Boaz

    2009-05-01

    Active control of sound has been employed to reduce noise levels around listeners' head using destructive interference from noise-canceling sound sources. Recently, spherical loudspeaker arrays have been studied as multiple-channel sound sources, capable of generating sound fields with high complexity. In this paper, the potential use of a spherical loudspeaker array for local active control of sound is investigated. A theoretical analysis of the primary and secondary sound fields around a spherical sound source reveals that the natural quiet zones for the spherical source have a shell-shape. Using numerical optimization, quiet zones with other shapes are designed, showing potential for quiet zones with extents that are significantly larger than the well-known limit of a tenth of a wavelength for monopole sources. The paper presents several simulation examples showing quiet zones in various configurations.

  5. Direct-radiator loudspeaker systems with high B1

    NARCIS (Netherlands)

    Vanderkooy, J.; Boers, P.M.; Aarts, R.M.

    2008-01-01

    In an extension of an earlier paper by the authors additional consequences of a dramatic increase in the motor strength Bl of a driver are shown. Not only is the efficiency of the loudspeaker and amplifier greatly increased, but high Bl values have a positive influence on other aspects of

  6. The importance of recording and playback technique for assessment of annoyance

    DEFF Research Database (Denmark)

    Celik, Emine; Persson Waye, Kerstin; Møller, Henrik

    2005-01-01

    in perception related to annoyance, loudness and unpleasantness between monophonic recordings played back through a loudspeaker and binaural recordings played back via headphones and to evaluate whether a possible difference depends on temporal and frequency characteristics as well as spatial characteristics...... a loudspeaker and the binaural recordings were presented through both closed (circum-aural) and completely open (free of the ear) headphones. The results show that for all judgments (annoyance, loudness and unpleasantness), there was no significant main effect of recording and playback techniques; however...

  7. The "boomerang" malleus-incus complex in congenital aural atresia.

    Science.gov (United States)

    Mukherjee, S; Kesser, B W; Raghavan, P

    2014-01-01

    "Boomerang" malleus-incus fusion deformity is identified on axial high-resolution CT in a subset of patients with congenital aural atresia, and it is associated with an absent incudostapedial joint and stapes capitulum and attachment of the incus to the tympanic segment of the facial nerve canal. Twelve patients with this deformity were identified on a retrospective review of imaging from a cohort of 673 patients with congenital aural atresia, with surgical confirmation in 9 of these patients. Eight of 9 patients underwent partial ossicular replacement prosthesis reconstruction with improvement in hearing outcome. We hypothesize that the boomerang anomaly represents a more severe ossicular anomaly than is normally seen in congenital aural atresia, arising from an arrest earlier in the embryonic development of the first and second branchial arch. This has potentially important implications for surgical planning because hearing outcomes with placement of prosthesis may not be as good as with conventional atresia surgery, in which reconstruction is performed with the patient's native ossicular chain. © 2014 by American Journal of Neuroradiology.

  8. Auralization of CFD Vorticity Using an Auditory Illusion

    Science.gov (United States)

    Volpe, C. R.

    2005-12-01

    One way in which scientists and engineers interpret large quantities of data is through a process called visualization, i.e. generating graphical images that capture essential characteristics and highlight interesting relationships. Another approach, which has received far less attention, is to present complex information with sound. This approach, called ``auralization" or ``sonification", is the auditory analog of visualization. Early work in data auralization frequently involved directly mapping some variable in the data to a sound parameter, such as pitch or volume. Multi-variate data could be auralized by mapping several variables to several sound parameters simultaneously. A clear drawback of this approach is the limited practical range of sound parameters that can be presented to human listeners without exceeding their range of perception or comfort. A software auralization system built upon an existing visualization system is briefly described. This system incorporates an aural presentation synchronously and interactively with an animated scientific visualization, so that alternate auralization techniques can be investigated. One such alternate technique involves auditory illusions: sounds which trick the listener into perceiving something other than what is actually being presented. This software system will be used to present an auditory illusion, known for decades among cognitive psychologists, which produces a sound that seems to ascend or descend endlessly in pitch. The applicability of this illusion for presenting Computational Fluid Dynamics data will be demonstrated. CFD data is frequently visualized with thin stream-lines, but thicker stream-ribbons and stream-tubes can also be used, which rotate to convey fluid vorticity. But a purely graphical presentation can yield drawbacks of its own. Thicker stream-tubes can be self-obscuring, and can obscure other scene elements as well, thus motivating a different approach, such as using sound. Naturally

  9. From Musical Detectives to DJs: Expanding Aural Skills and Analysis through Engaging Popular Music and Culture

    Science.gov (United States)

    Tobias, Evan S.

    2015-01-01

    Many music educators address aural skills and analysis by drawing on strategies designed for the realm of Western classical music. Focusing solely on aural skills and analysis within paradigms of Western music can limit students' musical learning and engagement to particular ways of knowing music. To diversify and broaden the types of aural skills…

  10. Hearing, listening, action: Enhancing nursing practice through aural awareness education.

    Science.gov (United States)

    Collins, Anita; Vanderheide, Rebecca; McKenna, Lisa

    2014-01-01

    Abstract Noise overload within the clinical environment has been found to interfere with the healing process for patients, as well as nurses' ability to assess patients effectively. Awareness and responsibility for noise production begins during initial nursing training and consequently a program to enhance aural awareness skills was designed for graduate entry nursing students in an Australian university. The program utilized an innovative combination of music education activities to develop the students' ability to distinguishing individual sounds (hearing), appreciate patients' experience of sounds (listening) and improve their auscultation skills and reduce the negative effects of noise on patients (action). Using a mixed methods approach, students reported heightened auscultation skills and greater recognition of both patients' and clinicians' aural overload. Results of this pilot suggest that music education activities can assist nursing students to develop their aural awareness and to action changes within the clinical environment to improve the patient's experience of noise.

  11. Limitations caused by distortion in room impulse response measurements by swept sine technique

    DEFF Research Database (Denmark)

    Stojic, Branko; Ciric, Dejan; Markovic, Milos

    2011-01-01

    The significance of a room impulse response implies the requirement that its measurement should have a high level of accuracy in certain applications. One of the common problems in a measurement process is nonlinearity leading to the distortion of a room impulse response. Limitations caused...... domain with or without memory. On the other hand, the distortion in measurements is achieved either by applying the nonlinearity model or by using higher excitation level and a loudspeaker with a highly nonlinear characteristic. The results show that the most of distortion energy is located in the non...

  12. Assessment of annoyance, loudness and unpleasantness with different recording and playback techniques

    DEFF Research Database (Denmark)

    Celik, Emine; Persson Waye, Kerstin; Møller, Henrik

    2005-01-01

    if there is a difference in perception related to annoyance, loudness and unpleasantness between monophonic recordings played back through a loudspeaker and binaural recordings played back via headphones and to evaluate whether a possible difference depends on temporal and frequency characteristics as well as spatial...... through a loudspeaker and the binaural recordings were presented through both closed (circum-aural) and completely open (free of the ear) headphones. The results show that for all judgments (annoyance, loudness and unpleasantness), there was no significant main effect of recording and playback techniques...

  13. Readability and quality assessment of websites related to microtia and aural atresia.

    Science.gov (United States)

    Alamoudi, Uthman; Hong, Paul

    2015-02-01

    Many parents and children utilize the Internet for health-related information, but the quality of these websites can vary. The objective of this study was to assess the quality and readability of microtia and aural atresia related websites. The search engine Google was queried with the terms 'microtia' and 'aural atresia.' The first 30 results were evaluated, and those websites containing original information written in English were reviewed. Quality of content was assessed with the DISCERN instrument, and readability was assessed with the Flesch-Kincaid Reading Grade Level (FKGL) and the Flesch Reading Ease Score (FRES) tests. Each website was also reviewed for ownership and the date of last update. Sixteen microtia and 14 aural atresia websites were included for full review. The mean DISCERN score for microtia websites was 54.4 (SD=8.3), and for aural atresia websites it was 47.6 (SD=10.7), which indicates 'good' and 'fair' quality of content, respectively. Readability assessments showed an average reading level requiring a grade 10 education on FKGL, and only one microtia (6.3%) and one aural atresia (7.1%) websites were deemed to be at 'reasonable' reading level on FRES. High-quality websites that are considered easily comprehensible to the general public were lacking. Since parents and children may use websites when making treatment decisions, physicians should be aware of the quality of health information pertaining to their area of expertise available on the Internet. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Effects of Musical Aptitude, Academic Ability, Music Experience, and Motivation on Aural Skills.

    Science.gov (United States)

    Harrison, Carole S.; And Others

    1994-01-01

    Reports on a study of 142 college music theory students on the influence of musical aptitude, academic ability, music experience, and motivation on the development of aural skills. Finds that musical aptitude had the largest effect on performance and motivation for music did not affect aural skills performance. (CFR)

  15. Sound field control with a circular double-layer array of loudspeakers

    DEFF Research Database (Denmark)

    Chang, Jiho; Jacobsen, Finn

    2012-01-01

    , and their performance is examined using computer simulations. Two performance indices are used in this work, (a) the level difference between the average sound energy density in the listening zone and that in the quiet zone (sometimes called “the acoustic contrast”), and (b) a normalized measure of the deviations...... between the desired and the generated sound field in the listening zone. It is concluded that the best compromise is obtained with a method that combines pure contrast maximization with a pressure matching technique.......This paper describes a method of generating a controlled sound field for listeners inside a circular array of loudspeakers without disturbing people outside the array appreciably. To achieve this objective, a double-layer array of loudspeakers is used. Several solution methods are suggested...

  16. Self-regulated learning of aural skills in undergraduate music courses: a case study

    Directory of Open Access Journals (Sweden)

    Pablo da Silva Gusmão

    2011-12-01

    Full Text Available Aural Skills classes, which are required and collective, present some particular issues at the Brazilian universities, such as the diverse student’s proficiency levels, motivational issues and lack of autonomy for learning. This paper present the results of a research that investigated the relationships between the psychological constructs involved in the self- regulation of aural skills learning in Undergraduate music students. Through semi-structured interviews, the objective was to understand the interaction of the processes described in Zimmerman (2002 in the three student’s narratives. In this initial research, it was possible to see a relationship between the achievement in Aural Skill courses and the utilization of self- regulatory process, particularly goal-setting and efficient time management, as well as the lack of strategies related to the division of goals into proximal and specific sub-goals, and to the definition of self-evaluation standards. The investigation of strategies for intervention on cognitive processes involved with self-regulated learning of aural skills may help students to become more motivated and autonomous in their academic study.

  17. Treatment of early and late reflections in a hybrid computer model for room acoustics

    DEFF Research Database (Denmark)

    Naylor, Graham

    1992-01-01

    The ODEON computer model for acoustics in large rooms is intended for use both in design (by predicting room acoustical indices quickly and easily) and in research (by forming the basis of an auralization system and allowing study of various room acoustical phenomena). These conflicting demands...... preclude the use of both ``pure'' image source and ``pure'' particle tracing methods. A hybrid model has been developed, in which rays discover potential image sources up to a specified order. Thereafter, the same ray tracing process is used in a different way to rapidly generate a dense reverberant decay...

  18. Modelling of horn-type loudspeakers for outdoor sound reinforcement systems

    DEFF Research Database (Denmark)

    Schuhmacher, Andreas; Rasmussen, Karsten Bo

    1999-01-01

    -type loudspeakers is made. The agreement between measured and calculated results is very good provided that a sufficient number of modes is included in the simulation. Simulation models of this kind represent one of the first steps towards a CAD tool for outdoor sound reinforcement systems....

  19. Aurally Aided Visual Search Performance Comparing Virtual Audio Systems

    DEFF Research Database (Denmark)

    Larsen, Camilla Horne; Lauritsen, David Skødt; Larsen, Jacob Junker

    2014-01-01

    Due to increased computational power, reproducing binaural hearing in real-time applications, through usage of head-related transfer functions (HRTFs), is now possible. This paper addresses the differences in aurally-aided visual search performance between a HRTF enhanced audio system (3D) and an...... with white dots. The results indicate that 3D audio yields faster search latencies than panning audio, especially with larger amounts of distractors. The applications of this research could fit virtual environments such as video games or virtual simulations.......Due to increased computational power, reproducing binaural hearing in real-time applications, through usage of head-related transfer functions (HRTFs), is now possible. This paper addresses the differences in aurally-aided visual search performance between a HRTF enhanced audio system (3D...

  20. Aurally Aided Visual Search Performance Comparing Virtual Audio Systems

    DEFF Research Database (Denmark)

    Larsen, Camilla Horne; Lauritsen, David Skødt; Larsen, Jacob Junker

    2014-01-01

    Due to increased computational power reproducing binaural hearing in real-time applications, through usage of head-related transfer functions (HRTFs), is now possible. This paper addresses the differences in aurally-aided visual search performance between an HRTF enhanced audio system (3D) and an...... with white dots. The results indicate that 3D audio yields faster search latencies than panning audio, especially with larger amounts of distractors. The applications of this research could fit virtual environments such as video games or virtual simulations.......Due to increased computational power reproducing binaural hearing in real-time applications, through usage of head-related transfer functions (HRTFs), is now possible. This paper addresses the differences in aurally-aided visual search performance between an HRTF enhanced audio system (3D...

  1. Time Varying Behavior of the Loudspeaker Suspension

    DEFF Research Database (Denmark)

    Pedersen, Bo Rohde; Agerkvist, Finn T.

    2007-01-01

    The suspension part of the electrodynamic loudspeaker is often modelled as a simple linear spring with viscous damping, however the dynamic behaviour of the suspension is much more complicated than predicted by such a simple model. At higher levels the compliance becomes non-linear and often chan...... changes during excitation at high levels. This paper investigates how the compliance of the suspension depends on the excitation, i.e. level and frequency content. The measurements are compared with other known measurement methods of the suspension....

  2. Modelling Viscoelasticity of Loudspeaker Suspensions using Retardation Spectra

    DEFF Research Database (Denmark)

    Ritter, Tobias; Agerkvist, Finn T.

    2010-01-01

    , the viscoelastic retardation spectrum, which provides a more fundamental description of the suspension viscoelasticity, is rst used to explain the accuracy of the empirical LOG creep model (Knudsen et al.). Then, two extensions to the LOG model are proposed which include the low and high frequency limit...... of the compliance, not accounted for in the original LOG model. The new creep models are veried by measurements on two 5.5 loudspeakers with different surrounds....

  3. Use of computerized data acquisition system to auralize NDE data for improved inspection capability

    International Nuclear Information System (INIS)

    Light, Glenn M.; Holt, Amos E.; Polk, Kent D.; Clayton, William T.

    2004-01-01

    Southwest Research Institute has developed computer-aided technology for converting electronic signals generated by conventional nondestructive evaluation (NDE) equipment (i.e., ultrasonic, eddy current, and acoustic emission) into audible information so that the inspector can make use of both the conventional NDE signals (which are often confusing) and the audible information to make a flaw/nonflaw decision. One objective of this work was to develop a computerized data acquisition system that could collect ultrasonic data, perform time dilation of the ultrasonic data, and help develop algorithms. The aural technology has been applied to composite impact damage, composite delamination detection, and corrosion detection. In addition, the aural technology was used to detect and discriminate intergranular stress corrosion cracking. Examples of application of aural NDE technology are described. (author)

  4. Timbral aspects of reproduced sound in small rooms. I

    DEFF Research Database (Denmark)

    Bech, Søren

    1995-01-01

    , has been simulated using an electroacoustic setup. The model included the direct sound, 17 individual reflections, and the reverberant field. The threshold of detection and just-noticeable differences for an increase in level were measured for individual reflections using eight subjects for noise......This paper reports some of the influences of individual reflections on the timbre of reproduced sound. A single loudspeaker with frequency-independent directivity characteristics, positioned in a listening room of normal size with frequency-independent absorption coefficients of the room surfaces...... and speech. The results have shown that the first-order floor and ceiling reflections are likely to individually contribute to the timbre of reproduced speech. For a noise signal, additional reflections from the left sidewall will contribute individually. The level of the reverberant field has been found...

  5. Monaural Congenital Deafness Affects Aural Dominance and Degrades Binaural Processing

    Science.gov (United States)

    Tillein, Jochen; Hubka, Peter; Kral, Andrej

    2016-01-01

    Cortical development extensively depends on sensory experience. Effects of congenital monaural and binaural deafness on cortical aural dominance and representation of binaural cues were investigated in the present study. We used an animal model that precisely mimics the clinical scenario of unilateral cochlear implantation in an individual with single-sided congenital deafness. Multiunit responses in cortical field A1 to cochlear implant stimulation were studied in normal-hearing cats, bilaterally congenitally deaf cats (CDCs), and unilaterally deaf cats (uCDCs). Binaural deafness reduced cortical responsiveness and decreased response thresholds and dynamic range. In contrast to CDCs, in uCDCs, cortical responsiveness was not reduced, but hemispheric-specific reorganization of aural dominance and binaural interactions were observed. Deafness led to a substantial drop in binaural facilitation in CDCs and uCDCs, demonstrating the inevitable role of experience for a binaural benefit. Sensitivity to interaural time differences was more reduced in uCDCs than in CDCs, particularly at the hemisphere ipsilateral to the hearing ear. Compared with binaural deafness, unilateral hearing prevented nonspecific reduction in cortical responsiveness, but extensively reorganized aural dominance and binaural responses. The deaf ear remained coupled with the cortex in uCDCs, demonstrating a significant difference to deprivation amblyopia in the visual system. PMID:26803166

  6. Monaural Congenital Deafness Affects Aural Dominance and Degrades Binaural Processing.

    Science.gov (United States)

    Tillein, Jochen; Hubka, Peter; Kral, Andrej

    2016-04-01

    Cortical development extensively depends on sensory experience. Effects of congenital monaural and binaural deafness on cortical aural dominance and representation of binaural cues were investigated in the present study. We used an animal model that precisely mimics the clinical scenario of unilateral cochlear implantation in an individual with single-sided congenital deafness. Multiunit responses in cortical field A1 to cochlear implant stimulation were studied in normal-hearing cats, bilaterally congenitally deaf cats (CDCs), and unilaterally deaf cats (uCDCs). Binaural deafness reduced cortical responsiveness and decreased response thresholds and dynamic range. In contrast to CDCs, in uCDCs, cortical responsiveness was not reduced, but hemispheric-specific reorganization of aural dominance and binaural interactions were observed. Deafness led to a substantial drop in binaural facilitation in CDCs and uCDCs, demonstrating the inevitable role of experience for a binaural benefit. Sensitivity to interaural time differences was more reduced in uCDCs than in CDCs, particularly at the hemisphere ipsilateral to the hearing ear. Compared with binaural deafness, unilateral hearing prevented nonspecific reduction in cortical responsiveness, but extensively reorganized aural dominance and binaural responses. The deaf ear remained coupled with the cortex in uCDCs, demonstrating a significant difference to deprivation amblyopia in the visual system. © The Author 2016. Published by Oxford University Press.

  7. Self-reported aural symptoms, headache and temporomandibular disorders in Japanese young adults.

    Science.gov (United States)

    Akhter, Rahena; Morita, Manabu; Ekuni, Disuke; Hassan, Nur Mohammad Monsur; Furuta, Michiko; Yamanaka, Reiko; Matsuka, Yoshizo; Wilson, David

    2013-02-06

    To investigate the associations of aural symptoms, headache and depression with the presence of temporomandibular disorder (TMD) symptoms in a young adult population in Japan. A personal interview survey was conducted on first-year university students (n = 1,930) regarding symptoms of TMD, aural problems, headache, shoulder pain and depression. Logistic regression was applied to assess the associations of these problems with the presence of TMD symptoms after controlling for age and gender. Among the 1,930 students, 543 students exhibited TMD symptoms and were classified into 7 groups: clicking only (Group I, n = 319), pain in the TMJ only (Group II, n = 21), difficulty in mouth opening only (Group III, n = 18), clicking and pain (Group IV, n = 29), clicking and difficulty in mouth opening (Group V, n = 48), difficulty in mouth opening and pain (Group VI, n = 11), and combination of three symptoms (Group VII, n = 97). The control group (n = 1,387) were subjects without any TMD symptoms. After adjusting for age and gender, a strong association was observed between TMD symptoms (Group II and IV) and tinnitus (OR = 12.1 and 13.2, respectively). TMD symptoms (Group I, II and III) were also associated with vertigo and headache. Otalgia and depression were significantly associated with the presence of clicking only. TMD symptoms were significantly correlated to aural symptoms and headache. A functional evaluation of the stomatognathic system should be considered in subjects with unexplained aural symptoms and headache.

  8. Listeners' expectation of room acoustical parameters based on visual cues

    Science.gov (United States)

    Valente, Daniel L.

    . The addressed visual makeup of the performer included: (1) an actual video of the performance, (2) a surrogate image of the performance, for example a loudspeaker's image reproducing the performance, (3) no visual image of the performance (empty room), or (4) a multi-source visual stimulus (actual video of the performance coupled with two images of loudspeakers positioned to the left and right of the performer). For this experiment, perceived auditory events of sound were measured in terms of two subjective spatial metrics: Listener Envelopment (LEV) and Apparent Source Width (ASW) These metrics were hypothesized to be dependent on the visual imagery of the presented performance. Data was also collected by participants matching direct and reverberant sound levels for the presented audio-visual scenes. In the final experiment, participants judged spatial expectations of an ensemble of musicians presented in the five physical spaces from Experiment 1. Supporting data was accumulated in two stages. First, participants were given an audio-visual matching test, in which they were instructed to align the auditory width of a performing ensemble to a varying set of audio and visual cues. In the second stage, a conjoint analysis design paradigm was explored to extrapolate the relative magnitude of explored audio-visual factors in affecting three assessed response criteria: Congruency (the perceived match-up of the auditory and visual cues in the assessed performance), ASW and LEV. Results show that both auditory and visual factors affect the collected responses, and that the two sensory modalities coincide in distinct interactions. This study reveals participant resiliency in the presence of forced auditory-visual mismatch: Participants are able to adjust the acoustic component of the cross-modal environment in a statistically similar way despite randomized starting values for the monitored parameters. Subjective results of the experiments are presented along with objective

  9. Extraction of 3D Information from Circular Array Measurements for Auralization with Wave Field Synthesis

    NARCIS (Netherlands)

    De Vries, D.; Hörchens, L.; Grond, P.

    2007-01-01

    The state of the art of wave field synthesis (WFS) systems is that they can reproduce sound sources and secondary (mirror image) sources with natural spaciousness in a horizontal plane, and thus perform satisfactory 2D auralization of an enclosed space, based on multitrace impulse response data

  10. Students' Performance When Aurally Identifying Musical Harmonic Intervals: Experimentation of a Teaching Innovation Proposal

    Science.gov (United States)

    Ponsatí, Imma; Miranda, Joaquim; Amador, Miquel; Godall, Pere

    2016-01-01

    The aim of the study was to measure the performance reached by students (N = 138) when aurally identifying musical harmonic intervals (from m2 to P8) after having experienced a teaching innovation proposal for the Music Conservatories of Catalonia (Spain) based on observational methodology. Its design took into account several issues, which had…

  11. Subjective impression of differences in realism, source width, and orientation between auralizations created from multi-channel anechoic recordings

    DEFF Research Database (Denmark)

    Vigeant, Michelle C.; Wang, Lily M.; Rindel, Jens Holger

    2005-01-01

    in realism and source width. Auralizations were made using three different types of musical instruments: woodwinds (flute), brass (trombone) and strings (violin). Subjects were asked to rate each musical track on a seven-point scale for the degree of realism and source width. An analysis of variance (ANOVA......) was carried out to determine the differences between the number of channels and the effect of instrument. A second test was conducted to assess the degree of difficulty in detecting source orientation (facing the audience or facing the stage wall) depending on the number of channels (one, four or thirteen......) and the amount of absorption in the room. [Work supported by the National Science Foundation.]...

  12. Flux Modulation in the Electrodynamic Loudspeaker

    DEFF Research Database (Denmark)

    Halvorsen, Morten; Tinggaard, Carsten; Agerkvist, Finn T.

    2015-01-01

    This paper discusses the effect of flux modulation in the electrodynamic loudspeaker with main focus on the effect on the force factor. A measurement setup to measure the AC flux modulation with static voice coil is explained and the measurements shows good consistency with FEA simulations....... Measurements of the generated AC flux modulation shows, that eddy currents are the main source to magnetic losses in form of phase lag and amplitude changes. Use of a copper cap shows a decrease in flux modulation amplitude at the expense of increased power losses. Finally, simulations show...... that there is a high dependency between the generated AC flux modulation from the voice coil and the AC force factor change....

  13. The Effect of Objective Room Acoustic Parameters on Auditory Steady-State Responses

    DEFF Research Database (Denmark)

    Zapata Rodriguez, Valentina; M. Harte, James; Jeong, Cheol-Ho

    2016-01-01

    -state responses (ASSR), recorded in a sound field is a promising technology to verify the hearing aid fitting. The test involves the presentation of the auditory stimuli via a loudspeaker, unlike the usual procedure of delivering via insert earphones. Room reverberation clearly may significantly affect...... the features of the stimulus important for eliciting a strong electrophysiological response, and thus complicate its detection. This study investigates the effect of different room acoustic conditions on recorded ASSRs via an auralisation approach using insert earphones. Fifteen normal-hearing listeners were...... tested using narrow-band (NB) CE-Chirps centered at the octave-bands of 0.5, 1.0, 2.0 and 4.0 kHz. These stimuli were convolved with impulse responses of three rooms simulated using a Green’s function approach to recreate different sound-field conditions. Comparisons with the unmodified stimuli...

  14. Comparison of Power Supply Pumping of Switch-Mode Audio Power Amplifiers with Resistive Loads and Loudspeakers as Loads

    DEFF Research Database (Denmark)

    Knott, Arnold; Petersen, Lars Press

    2013-01-01

    Power supply pumping is generated by switch-mode audio power amplifiers in half-bridge configuration, when they are driving energy back into their source. This leads in most designs to a rising rail voltage and can be destructive for either the decoupling capacitors, the rectifier diodes...... in the power supply or the power stage of the amplifier. Therefore precautions are taken by the amplifier and power supply designer to avoid those effects. Existing power supply pumping models are based on an ohmic load attached to the amplifier. This paper shows the analytical derivation of the resulting...... waveforms and extends the model to loudspeaker loads. Measurements verify, that the amount of supply pumping is reduced by a factor of 4 when comparing the nominal resistive load to a loudspeaker. A simplified and more accurate model is proposed and the influence of supply pumping on the audio performance...

  15. Self-reported aural symptoms, headache and temporomandibular disorders in Japanese young adults

    Directory of Open Access Journals (Sweden)

    Akhter Rahena

    2013-02-01

    Full Text Available Abstract Background To investigate the associations of aural symptoms, headache and depression with the presence of temporomandibular disorder (TMD symptoms in a young adult population in Japan. Methods A personal interview survey was conducted on first-year university students (n = 1,930 regarding symptoms of TMD, aural problems, headache, shoulder pain and depression. Logistic regression was applied to assess the associations of these problems with the presence of TMD symptoms after controlling for age and gender. Results Among the 1,930 students, 543 students exhibited TMD symptoms and were classified into 7 groups: clicking only (Group I, n = 319, pain in the TMJ only (Group II, n = 21, difficulty in mouth opening only (Group III, n = 18, clicking and pain (Group IV, n = 29, clicking and difficulty in mouth opening (Group V, n = 48, difficulty in mouth opening and pain (Group VI, n = 11, and combination of three symptoms (Group VII, n = 97. The control group (n = 1,387 were subjects without any TMD symptoms. After adjusting for age and gender, a strong association was observed between TMD symptoms (Group II and IV and tinnitus (OR = 12.1 and 13.2, respectively. TMD symptoms (Group I, II and III were also associated with vertigo and headache. Otalgia and depression were significantly associated with the presence of clicking only. Conclusions TMD symptoms were significantly correlated to aural symptoms and headache. A functional evaluation of the stomatognathic system should be considered in subjects with unexplained aural symptoms and headache.

  16. Low Impedance Voice Coils for Improved Loudspeaker Efficiency

    DEFF Research Database (Denmark)

    Iversen, Niels Elkjær; Knott, Arnold; Andersen, Michael A. E.

    2015-01-01

    In modern audio systems utilizing switch-mode amplifiers the total efficiency is dominated by the rather poor efficiency of the loudspeaker. For decades voice coils have been designed so that nominal resistances of 4 to 8 Ohms is obtained, despite modern audio amplifiers, using switch-mode techno...... responses are estimated. For this woofer it is shown that the sensitivity can be improved approximately 1 dB, corresponding to a 30% efficiency improvement, just by increasing the fill factor using a low impedance voice coil with rectangular wire....

  17. Timbral aspects of reproduced sound in small rooms. II

    DEFF Research Database (Denmark)

    Bech, Søren

    1996-01-01

    A single loudspeaker with frequency-dependent directivity characteristics, positioned in a room of normal size with frequency-dependent absorption coefficients of the room surfaces, has been simulated using an electroacoustic setup. The model included the direct sound, seventeen individual...... reflections and the reverberant field. The threshold of detection, and just-noticeable differences for an increase in level were measured for individual reflections. The results have confirmed that the first-order floor reflection is likely to contribute individually to the timbre of reproduced noise. However......, for a speech signal none of the investigated reflections will contribute individually to the timbre. It is suggested that the threshold of detection is determined by the spectral changes in the dominant frequency range of 500 Hz to 2 kHz. For increases in the level of individual reflections, the most likely...

  18. Control of sound fields with a circular double-layer array of loudspeakers

    DEFF Research Database (Denmark)

    Chang, Jiho; Jacobsen, Finn

    2012-01-01

    by the Kirchhoff-Helmholtz integral theorem a double-layer array of loudspeakers is used. Several solution methods are suggested and examined with computer simulations: pure contrast control, pure pressure matching, and a weighted combination. In order to compare the performance of the methods two performance...

  19. Experimental evaluation of the omnidirectional behavior of platonic polyhedron loudspeakers

    Science.gov (United States)

    Rollins, Sarah; Leishman, Timothy; Dix, Gordon

    2003-10-01

    Many architectural acoustics measurements require the use of an omnidirectional source. For several years, the source predominantly used for such applications has been the dodecahedron loudspeaker with small in-phase drivers mounted in each face. While other platonic polyhedron loudspeakers (PPLs) have not been used as frequently, they also produce nearly omnidirectional fields over limited bandwidths. Above cutoff frequencies specific to their geometries, all PPLs depart from ideal omnidirectional behavior, with varying degrees of directivity. While these cutoff frequencies are typically higher for higher-order polyhedra, they commonly fall within the bandwidths of standard measurements. The five types of PPLs have been constructed and measured to gain greater insight into their omnidirectional behaviors. Their frequency responses were taken at 2664 points over a sphere (5-deg polar and azimuthal angle increments) in an anechoic chamber. The measurements were then processed to produce directivity balloon plots. However, to better compare directivities and find the source consistently producing the most omnidirectional field over a useful bandwidth, a frequency-dependent standard deviation formula was implemented. Average values of the standard deviation parameter produce figures of merit that further characterize omnidirectionality. [Research supported by funding from the NSF REU program.

  20. Aural mapping of STEM concepts using literature mining

    Science.gov (United States)

    Bharadwaj, Venkatesh

    Recent technological applications have made the life of people too much dependent on Science, Technology, Engineering, and Mathematics (STEM) and its applications. Understanding basic level science is a must in order to use and contribute to this technological revolution. Science education in middle and high school levels however depends heavily on visual representations such as models, diagrams, figures, animations and presentations etc. This leaves visually impaired students with very few options to learn science and secure a career in STEM related areas. Recent experiments have shown that small aural clues called Audemes are helpful in understanding and memorization of science concepts among visually impaired students. Audemes are non-verbal sound translations of a science concept. In order to facilitate science concepts as Audemes, for visually impaired students, this thesis presents an automatic system for audeme generation from STEM textbooks. This thesis describes the systematic application of multiple Natural Language Processing tools and techniques, such as dependency parser, POS tagger, Information Retrieval algorithm, Semantic mapping of aural words, machine learning etc., to transform the science concept into a combination of atomic-sounds, thus forming an audeme. We present a rule based classification method for all STEM related concepts. This work also presents a novel way of mapping and extracting most related sounds for the words being used in textbook. Additionally, machine learning methods are used in the system to guarantee the customization of output according to a user's perception. The system being presented is robust, scalable, fully automatic and dynamically adaptable for audeme generation.

  1. Use of laterally placed vacuum drains for management of aural hematomas in five dogs.

    Science.gov (United States)

    Pavletic, Michael M

    2015-01-01

    5 dogs (a Newfoundland, Golden Retriever, Shiba Inu, Staffordshire Terrier, and Vizsla) were referred for evaluation and treatment of unilateral aural hematomas within a week after their formation. Aural hematomas involved the left (3) or right (2) ears. With patients under anesthesia, the aural hematomas were approached surgically from the convex, or lateral, pinnal surface. Two small incisions were used to position a vacuum drain into the incised hematoma cavity. The drain exited at the base of the pinna and adjacent cervical skin. The free end of the drain was attached to a vacuum reservoir for 18 to 21 days. Drains and skin sutures were removed at this time along with the protective Elizabethan collar. All hematomas resolved and surgical sites healed during the minimum 6-month follow-up period. Cosmetic results were considered excellent in 4 of 5 patients. Slight wrinkling of the pinna in 1 patient resulted from asymmetric enlargement of the cartilaginous walls of the hematoma, where vacuum application resulted in a slight folding of the redundant lateral cartilage wall. The described treatment was efficient, economical, and minimally invasive and required no bandaging or wound care. Placement of the drain tubing on the convex (lateral) aspect sheltered the system from displacement by patients with an Elizabethan collar in place. Overall cosmetic results were excellent; asymmetric enlargement of the cartilaginous walls of the hematoma with slight folding of the pinna was seen in 1 patient.

  2. Free-field correction values for Interacoustics DD 45 supra-aural audiometric earphones

    DEFF Research Database (Denmark)

    Poulsen, Torben

    2010-01-01

    This paper report free-field correction values for the Interacoustics DD 45 audiometric earphones. The free-field correction values for earphones provide the loudness based equivalence to loudspeaker presentation. Correction values are especially used for the calibration of audiometric equipment...... for the acoustic coupler IEC 60318-3 (NBS 9-A) and for the ear simulator IEC 60318-1. The results are in good agreement with the results of another independent investigation. The reported free-field correction values may be used as part of the basis for future standardization of the DD 45 earphone....

  3. Social media interruption affects the acquisition of visually, not aurally, acquired information during a pathophysiology lecture.

    Science.gov (United States)

    Marone, Jane R; Thakkar, Shivam C; Suliman, Neveen; O'Neill, Shannon I; Doubleday, Alison F

    2018-06-01

    Poor academic performance from extensive social media usage appears to be due to students' inability to multitask between distractions and academic work. However, the degree to which visually distracted students can acquire lecture information presented aurally is unknown. This study examined the ability of students visually distracted by social media to acquire information presented during a voice-over PowerPoint lecture, and to compare performance on examination questions derived from information presented aurally vs. that presented visually. Students ( n = 20) listened to a 42-min cardiovascular pathophysiology lecture containing embedded cartoons while taking notes. The experimental group ( n = 10) was visually, but not aurally, distracted by social media during times when cartoon information was presented, ~40% of total lecture time. Overall performance among distracted students on a follow-up, open-note quiz was 30% poorer than that for controls ( P < 0.001). When the modality of presentation (visual vs. aural) was compared, performance decreased on examination questions from information presented visually. However, performance on questions from information presented aurally was similar to that of controls. Our findings suggest the ability to acquire information during lecture may vary, depending on the degree of competition between the modalities of the distraction and the lecture presentation. Within the context of current literature, our findings also suggest that timing of the distraction relative to delivery of material examined affects performance more than total distraction time. Therefore, when delivering lectures, instructors should incorporate organizational cues and active learning strategies that assist students in maintaining focus and acquiring relevant information.

  4. Therapeutic implications in the treatment of aural Pseudomonas infections based on in vitro susceptibility patterns.

    Science.gov (United States)

    Dohar, J E; Kenna, M A; Wadowsky, R M

    1995-09-01

    To examine the in vitro susceptibility patterns of aural isolates of Pseudomonas aeruginosa and to identify changes over a 4-year period. Retrospective case series. The outpatient department at Children's Hospital of Pittsburgh (Pa), a tertiary referral center. Ambulatory children younger than 18 years from whose ears P aeruginosa was isolated. The in vitro susceptibility of aural isolates of P aeruginosa to ampicillin, cefotaxime, chloramphenicol, sulfisoxazole, ticarcillin, mezlocillin, gentamicin, tobramycin, cefazolin, tetracycline, piperacillin, nitrofurantoin, cephalexin hydrochloride, ceftriaxone, cefuroxime axetil, and sulfamethoxazole-trimethoprim. No changes were found in the trends of the susceptibility patterns over the 4-year study period, with the exception of the semisynthetic penicillins, ticarcillin and mezlocillin. These two agents were found to be relatively ineffective against the strains of P aeruginosa isolated in 1989 (59% and 18% susceptibility, respectively). This finding is in contrast to their effectiveness over the remainder of the study period (96% and 90% susceptibility, respectively), which was excellent. These observations likely reflect a change in the breakpoints for the minimal inhibitory concentrations between these periods. The intravenous agent with the best susceptibility profile was piperacillin (96%). Of the aminoglycosides tested, 94% of the isolates were sensitive to tobramycin, as opposed to only 79% for gentamicin. This finding may have significance when one is empirically selecting ototopical therapy, since both tobramycin and gentamicin are available as topical preparations. Of the oral agents, the combination of sulfamethoxazole-trimethoprim was most effective (46%).

  5. Audibility of individual reflections in a complete sound field, III

    DEFF Research Database (Denmark)

    Bech, Søren

    1996-01-01

    This paper reports on the influence of individual reflections on the auditory localization of a loudspeaker in a small room. The sound field produced by a single loudspeaker positioned in a normal listening room has been simulated using an electroacoustic setup. The setup models the direct sound......-independent absorption coefficients of the room surfaces, and (2) a loudspeaker with directivity according to a standard two-way system and absorption coefficients according to real materials. The results have shown that subjects can distinguish reliably between timbre and localization, that the spectrum level above 2 k...

  6. Usage of measured reverberation tail in a binaural room impulse response synthesis

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Madsen, Esben

    2011-01-01

    The aim of the modern communication technologies is an immersive experience. One of the applications that should provide the feeling of being together and sharing the same environment during the communication process is BEAMING. The goal of this paper is to improve audible spatial impression...... utilizing correct acoustical properties of the specific environments. Binaural room impulse response (BRIR) synthesis represents one of the main tasks in the binaural auralization. When the BRIRs are simulated, high order reflections (reverberation tail) are usually modeled statistically because of the high...

  7. Effects of Music Notation Reinforcement on Aural Memory for Melodies

    Science.gov (United States)

    Buonviri, Nathan

    2015-01-01

    The purpose of this study was to investigate effects of music notation reinforcement on aural memory for melodies. Participants were 41 undergraduate and graduate music majors in a within-subjects design. Experimental trials tested melodic memory through a sequence of target melodies, distraction melodies, and matched and unmatched answer choices.…

  8. Design Considerations for Aural Vital Signs Using PZT Piezoelectric Ceramics Sensor Based on the Computerization Method

    Directory of Open Access Journals (Sweden)

    Jerapong Tantrakoon

    2007-11-01

    Full Text Available The purpose was to illustrate how system developed for measurement of the aural vital signs such as patient’s heart and lung sounds in the hospital. For heart sounds measurement must operate the frequency response between 20 – 800 Hz, and lung sounds measurement must operate the frequency response between 160 – 4,000 Hz. The method was designed PZT piezoelectric ceramics for both frequency response in the same PZT sensor. It converts a signal from aural vital sign form to voltage signal. The signal is suitably amplified and re-filtered in band pass frequency band. It is converted to digital signal by an analog to digital conversion circuitry developed for the purpose. The results were that all signals can fed to personal computer through the sound card port. With the supporting software for drawing of graphic on the screen, the signal for a specific duration is accessed and stored in the computer’s memory in term of each patient’s data. In conclusion, the data of each patient call dot pcg (.pcg for drawing graph and dot wave (.wave for sound listening or automatic sending via electronic mail to the physician for later analysis of interpreting the sounds on the basis of their time domain and frequency domain representation to diagnose heart disorders.

  9. Nanogenerator-based dual-functional and self-powered thin patch loudspeaker or microphone for flexible electronics

    Science.gov (United States)

    Li, Wei; Torres, David; Díaz, Ramón; Wang, Zhengjun; Wu, Changsheng; Wang, Chuan; Lin Wang, Zhong; Sepúlveda, Nelson

    2017-05-01

    Ferroelectret nanogenerators were recently introduced as a promising alternative technology for harvesting kinetic energy. Here we report the device's intrinsic properties that allow for the bidirectional conversion of energy between electrical and mechanical domains; thus extending its potential use in wearable electronics beyond the power generation realm. This electromechanical coupling, combined with their flexibility and thin film-like form, bestows dual-functional transducing capabilities to the device that are used in this work to demonstrate its use as a thin, wearable and self-powered loudspeaker or microphone patch. To determine the device's performance and applicability, sound pressure level is characterized in both space and frequency domains for three different configurations. The confirmed device's high performance is further validated through its integration in three different systems: a music-playing flag, a sound recording film and a flexible microphone for security applications.

  10. Effects of Various Architectural Parameters on Six Room Acoustical Measures in Auditoria.

    Science.gov (United States)

    Chiang, Wei-Hwa

    The effects of architectural parameters on six room acoustical measures were investigated by means of correlation analyses, factor analyses and multiple regression analyses based on data taken in twenty halls. Architectural parameters were used to estimate acoustical measures taken at individual locations within each room as well as the averages and standard deviations of all measured values in the rooms. The six acoustical measures were Early Decay Time (EDT10), Clarity Index (C80), Overall Level (G), Bass Ratio based on Early Decay Time (BR(EDT)), Treble Ratio based on Early Decay Time (TR(EDT)), and Early Inter-aural Cross Correlation (IACC80). A comprehensive method of quantifying various architectural characteristics of rooms was developed to define a large number of architectural parameters that were hypothesized to effect the acoustical measurements made in the rooms. This study quantitatively confirmed many of the principles used in the design of concert halls and auditoria. Three groups of room architectural parameters such as the parameters associated with the depth of diffusing surfaces were significantly correlated with the hall standard deviations of most of the acoustical measures. Significant differences of statistical relations among architectural parameters and receiver specific acoustical measures were found between a group of music halls and a group of lecture halls. For example, architectural parameters such as the relative distance from the receiver to the overhead ceiling increased the percentage of the variance of acoustical measures that was explained by Barron's revised theory from approximately 70% to 80% only when data were taken in the group of music halls. This study revealed the major architectural parameters which have strong relations with individual acoustical measures forming the basis for a more quantitative method for advancing the theoretical design of concert halls and other auditoria. The results of this study provide

  11. Three-dimensional assessment of the temporal bone and mandible deformations in patients with congenital aural atresia.

    Science.gov (United States)

    Fu, Yaoyao; Li, Chenlong; Dai, Peidong; Zhang, Tianyu

    2017-10-01

    To investigate the deformations of temporal bone and mandible combined with congenital aural atresia. A total of 158 patients with congenital aural atresia were included in the study. The raw CT data of the temporal bone was imported into MIMICS v 12 and threshold dissection, region growing and three-dimensional (3D) calculation were used to calculate 3D models. The 3D characteristics of the temporal bone and upper part of mandible were assessed. The tympanic part of the temporal bone was all undeveloped. Of all the patients included, 14 patients were found to have severe maxillofacial malformations. Among them, 2 cases have floating arch, 4 cases have interrupted arch, 5 cases have mandibular processes hypoplasia and 3 cases have interrupted arch combined with severe maxillary malformation. Ten of the 14 patients were suffered from dysplasia of the mastoid part of the temporal bone as well. Maxillofacial malformations may sometimes coexist with congenital aural atresia. Otolaryngologists should not neglect the coexisted maxillofacial malformations and give timely referral to maxillofacial surgeons. Copyright © 2017. Published by Elsevier B.V.

  12. Actualities of Management of Aural, Nasal, and Throat Foreign Bodies

    African Journals Online (AJOL)

    Prevalence was predominantly among the under 5 s; 286/594 (P = 0.001). ENT Fbs were 356/594 (59.9%), 167/594 (28.1%) and 71/59 (12.0%), respectively. Cotton wool 133/356 (37.4%) and beads 75/356 (21.1%) constituted most aural Fbs. Beads 45/167 (27.0%) and grains/seed 37/167 (22.1%) were the most common ...

  13. Sound Effects: The Oral/Aural Dimensions of Literature in English Introduction

    Directory of Open Access Journals (Sweden)

    Chris Jones

    2009-10-01

    Full Text Available _Sound Effects_ traces the history of the relationship between oral conditions and aural effect in English literature from its beginnings in the Anglo-Saxon period through to the twenty-first century. Few collections nowadays, other than textbook histories, would attempt a survey of their field from the early middle ages to the present day, and it is not our intention here to offer a continuous narrative. But despite the many centuries covered by this collection, the reader will find that certain themes recur in different contexts and that the individual essays speak to each other, often over long distances of time. It ends where it might have begun, with Homer, though in modern English form. The effect of this pattern is to create an “envelope” structure in which the ancient oral forms of Greek and Anglo-Saxon verse reappear as contexts for understanding how these forms survive and how sound works in the poetry of the modern world. The scope of the volume is also determined by its subject, since we are concerned with tradition as well as with the oral and aural. In particular, we are concerned with how literary production and reception respond to the different waves of media evolution from oral to written, manuscript to print (and the theater, and the later development of machine technology. We are not specifically concerned with the computer and the Internet, though they are an unstated presence behind the project as a whole. A subsidiary theme is the way in which sound, understood in both oral and aural terms, provides the agency through which high and low, elite and popular cultures are brought into conjunction throughout English literature.

  14. Aural Myiasis in A 2-Week Old Neonate - Case Report | Adegboye ...

    African Journals Online (AJOL)

    Aural myiasis, particularly in neonate, is rare, and the average practitioner of pediatrics is less likely to see a case. We present a 2- week old male neonate seen at Federal Medical Centre, Azare, Bauchi State of Nigeria with four days history of left ear chocolate – colour discharge and inconsolable cry before presentation.

  15. The Movement of Air, the Breath of Meaning: Aurality and Multimodal Composing

    Science.gov (United States)

    Selfe, Cynthia L.

    2009-01-01

    Rhetoric and composition's increasing attention to multimodal composing involves challenges that go beyond issues of access to digital technologies and electronic composing environments. As a specific case study, this article explores the history of aural composing modalities (speech, music, sound) and examines how they have been understood and…

  16. Aurally Handicapped -- Research; A Selective Bibliography. Exceptional Child Bibliography Series No. 625.

    Science.gov (United States)

    Council for Exceptional Children, Reston, VA. Information Center on Exceptional Children.

    The selected bibliography of research on aurally handicapped children contains approximately 95 abstracts with indexing information explained to be drawn from the computer file of abstracts representing the Council for Exceptional Children Information Center's complete holdings as of August, 1972. Abstracts are said to be chosen using the criteria…

  17. Decisional Conflict in Parents Considering Bone-Anchored Hearing Devices in Children With Unilateral Aural Atresia.

    Science.gov (United States)

    Graham, M Elise; Haworth, Rebecca; Chorney, Jill; Bance, Manohar; Hong, Paul

    2015-12-01

    The benefits of bone-anchored hearing devices (BAHD) in children with unilateral aural atresia are controversial. We sought to determine whether there is parental decisional conflict surrounding elective placement of BAHD for this indication. Caregivers of pediatric patients with unilateral aural atresia and normal contralateral ear undergoing percutaneous BAHD consultation were enrolled. All consultations were carried out by one pediatric otolaryngologist in a consistent manner. After consultation, the participants completed a demographics form and the Decisional Conflict Scale (DCS) questionnaire. Twenty-three caregivers of 15 male (65.2%) and 8 female (34.8%) children (mean age 5.65 years) participated. The overall median DCS score was 15.63 (standard error = 4.21). Significant decisional conflict (DCS score ≥ 25) was found in 10 participants (43.5%). The median DCS score in the group choosing surgery was 5.47, and it was 23.44 in those who did not choose surgery (Mann-Whitney U = 39, Z = -1.391, P = .164). The median DCS score for mothers and fathers was 25 and 3.91, respectively. Many parents experienced significant decisional conflict when considering percutaneous BAHD surgery in children with unilateral aural atresia in our study population. Future research should explore the impact of decisional conflict on health outcomes. © The Author(s) 2015.

  18. Using Authentic Aural Materials to Develop Listening Comprehension in the EFL Classroom

    Science.gov (United States)

    Ghaderpanahi, Leila

    2012-01-01

    The purpose of this study was to examine the influences of authentic aural materials on listening ability of thirty female undergraduate psychology majors studying English as a foreign language. It basically focused on using authentic materials and real-life situations as part of the communicative approach. The results of the listening…

  19. An Aural Learning Project: Assimilating Jazz Education Methods for Traditional Applied Pedagogy

    Science.gov (United States)

    Gamso, Nancy M.

    2011-01-01

    The Aural Learning Project (ALP) was developed to incorporate jazz method components into the author's classical practice and her applied woodwind lesson curriculum. The primary objective was to place a more focused pedagogical emphasis on listening and hearing than is traditionally used in the classical applied curriculum. The components of the…

  20. Impact of loudspeaker nonlinear distortion on personal sound zones

    DEFF Research Database (Denmark)

    Ma, Xiaohui; J. Hegarty, Patrick; Abildgaard Pedersen, Jan

    2018-01-01

    Personal sound zone systems aim at creating multiple listening zones within a shared space with minimum interference between zones, but the performance is often poorer than simulations predict and effects of nonlinear distortion are sometimes audible. This paper assesses the impact of nonlinear...... distortion on sound zones through simulations and measurements performed under anechoic conditions. Two sound zones, one bright and one dark, are created with acoustic contrast control using two loudspeaker arrays driven at 250 Hz. Nonlinear distortion is modelled using second or third order nonlinearities....... Simulations show that nonlinear distortion degrades the acoustic contrast, which is confirmed by experimental measurements. The harmonic distortion is audible in the dark zone. Frequency resolved measurements reveal that harmonic distortion contributes to contrast loss, but nonlinear effects...

  1. Room acoustic transition time based on reflection overlap

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Brunskog, Jonas; Jacobsen, Finn

    2010-01-01

    A transition time is defined based on the temporal overlap of reflected pulses in room impulse responses. Assuming specular reflections only, the temporal distance between adjacent reflections, which is proportional to the volume of a room, is compared with the characteristic width of a pulse at ...... in a room with nonuniform absorption and furniture than in a room that satisfies the underlying assumptions....

  2. Room acoustic transition time based on reflection overlap

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Brunskog, Jonas; Jacobsen, Finn

    2013-01-01

    A transition time is defined based on the temporal overlap of reflected pulses in room impulse responses. Assuming specular reflections only, the temporal distance between adjacent reflections, which is proportional to the volume of a room, is compared with the characteristic width of a pulse at ...... in a room with nonuniform absorption and furniture than in a room that satisfies the underlying assumptions....

  3. Presentation of Aural Stimuli to Newborns and Premature Infants: An Audiological Perspective.

    Science.gov (United States)

    Cassidy

    1999-01-01

    The purpose of this study was twofold: (a) to examine extant research in the field of music with premature and full term infants in order to identify protocols being used in the presentation of musical stimuli to neonates and (b) to use knowledge gleaned from audiology as a basis for suggesting a standardized protocol for use of musical stimuli with infants. Articles considered appropriate for inclusion in the analysis met the following criteria: (a) presented data for the effects of music on a dependent measure, (b) had subjects who were identified as either premature or term newborns receiving treatment after birth and prior to discharge from the hospital, and (c) used music for some or all of the aural stimuli. Articles (N = 20) were categorized by demographic information, types of aural stimuli, independent variables, dependent measures, and protocol used to present the musical stimuli. Of primary importance to this study was the protocol used in each study to present musical stimuli. Data regarding total duration of stimuli per day, longest duration of stimuli per day, method of stimuli presentation, placement of speakers, decibel level of stimuli, and where;he decibel level was measured reveal that there is no standard protocol being followed with regard to the presentation of aural stimuli. Recommendations include future research on (a) determining a minimum gestational age where music therapy may be appropriate, (b) determining the frequency spectrum perceived by a premature infant, (c) determining the decibel levels reaching the ear drum and assessing appropriate levels for minimum stimulation with maximum results, and (d) carefully considering the method of stimulus presentation as it will have an impact on the decibel level reaching the ear drum of these infants.

  4. Experiences of an Internet-based aural rehabilitation (IAR) program for hearing aid users: a qualitative study.

    Science.gov (United States)

    Malmberg, Milijana; Sundewall Thorén, Elisabet; Öberg, Marie; Lunner, Thomas; Andersson, Gerhard; Kähäri, Kim

    2018-04-24

    Internet interventions for hearing aid (HA) users have been shown to be effective in helping persons with hearing problems. As earlier research refers to objective data on these effects, little is known about how participants experience the Internet interventions subjectively. The aim of the present study was to explore participants' experiences of an Internet-based aural rehabilitation (IAR) program for HA-users, and to explore the possible subjective benefits of such a program. A qualitative exploratory design was implemented involving semi-structured telephone interviews. The interviews were transcribed and analysed using content analysis. Interviews were conducted with 20 participants (9 men and 11 women) who had completed an IAR program for HA-users. The participants were 57-81 years old and had used HAs for 2-25 years. The results are organised in three main categories: general experiences associated with participating in the program, knowledge obtained from the program and perceived impact of taking part in the program. The overall results indicate positive experiences of the IAR program, and an overreaching theme of increased self-esteem was identified. The findings provide some valuable information for developers of future IAR programs.

  5. Development of Dynamic Loudspeakers Modified as Incident Pressure Sources for Noise Reductiuon in a Double Panel Structure

    NARCIS (Netherlands)

    Ho, J.H.; Berkhoff, A.P.

    2013-01-01

    This paper presents a modified loudspeaker source for decentralized feedback cavity control in a double panel structure to reduce the noise transmission. The double panel structure con-sists of two panels with air in between and offers the advantages of low weight, low sound transmission at high

  6. Development of dynamic loudspeakers modified as incident pressure sources for noise reduction in a double panel structure

    NARCIS (Netherlands)

    Ho, J.; Berkhoff, Arthur P.; Crocker, Malcolm J.; Pawelczyk, Marek; Paosawatyanyong, Boonchoat

    2013-01-01

    This paper presents a modified loudspeaker source for decentralized feedback cavity control in a double panel structure to reduce the noise transmission. The double panel structure con-sists of two panels with air in between and offers the advantages of low weight, low sound transmission at high

  7. The comparison of balance performance among children with cochlear implantation, post-aural aid and normal children

    Directory of Open Access Journals (Sweden)

    Arezoo Ahmad pour

    2014-11-01

    Full Text Available Background: This cross-sectional study was carried out to compare balance performance between children with cochlear implants and post-aural aid and normal children. Methods: The present study was done on 67 severe to profound hearing impaired children. Of these, 21 children with an average age of 7 years and 4 months (±1.7 wore cochlear implant, 46 children with an average age of 7 years and 7 months (±1.7 wore post-aural aid and 60 children with an average 8 years and one month (±11 months were considered as a control group. All of the children were tested with the 9-stage balance subtest of Bruininks-Oseretsky Test of Motor Proficiency2 (BOT2. Results: The mean total BOT2 score of hearing impaired children was significantly lower than the normal group (P≤0.001. The mean total BOT2 score among children with cochlear implant, post-aural aids and normal group showed that cochlear implant group significantly performed weaker than the other two groups (P≤0.001. Conclusion: Hearing impaired children particularly children with cochlear implant are exposed to the risk of balance deficit. Hearing impaired children specially those who wear cochlear implants must be screened for vestibular hypofunction.

  8. Time varying behavior of the loudspeaker suspension: Displacement level dependency

    DEFF Research Database (Denmark)

    Agerkvist, Finn T.; Pedersen, Bo Rohde

    2009-01-01

    The compliance of the loudspeaker suspension is known to depend on the recent excitation level history. Previous investigations have shown that the electrical power as well as displacement and velocity plays a role. In this paper the hypothesis that the changes in compliance are caused mainly...... by how much the suspension has been stretched, i.e. the maximum displacement, is investigated. For this purpose the changes in compliance are measured when exposing the speaker to different levels and types of electrical excitation signals, as well as mechanical excitation only. For sinusoidal excitation...... the change in compliance is shown to depend primarily on maximum displacement. But for square pulse excitation the duration of the excitation also plays an important role...

  9. Occlusal management for a patient with aural symptoms of unknown etiology: a case report

    Directory of Open Access Journals (Sweden)

    Torii Kengo

    2007-09-01

    Full Text Available Abstract Background Although the discrepancy between the habitual occlusal position (HOP and the flat bite plate-induced occlusal position (BPOP (regarded as the muscular physiological reference position has been recently reported to be related to symptoms of temporomandibular disorders (TMDs, it still remains unclear whether the occlusal equilibration in the reference position is effective to resolve TMD-related discrepancy and symptoms. Aural symptoms (otalgia, tinnitus, vertigo et cetera have been included under TMD symptoms. Methods To examine the effect of occlusal equilibration for the treatment of TMDs, occlusal equilibration was performed for a patient with aural symptoms (otalgia, tinnitus and vertigo of unknown etiology in the right ear. An occlusal analysis was performed on this patient with dental models mounted on an articulator after relieving painful symptoms by an appliance therapy and a discrepancy was identified (p Results At completion of treatment, the discrepancy was not significant (p > 0.25, and the patient's right condyle had shifted 2.8 mm posteromedially in the horizontal plane, and the left condyle had shifted 1.0 mm laterally in the voluntarily closed position from the previous HOP. The aural symptoms of the patient were resolved, and there has been no recurrence to date after a two-year follow-up period. Conclusion An occlusal analysis should be performed in patients exhibiting TMD symptoms to identify the presence or absence of any discrepancy between the HOP and the BPOP. If a discrepancy exists, occlusal equilibration should be attempted in the reference position.

  10. Children's Aural and Kinesthetic Understanding of Rhythm: Developing an Instructional Model

    Science.gov (United States)

    Foley, Adam D.

    2013-01-01

    The purpose of this study was to develop a deeper understanding of aural and kinesthetic rhythm skill development in elementary school-age children. In this study, I examined my curriculum model for rhythm understanding, which included creating and implementing assessments of movement skills in meter and rhythm. The research questions were: 1.…

  11. Congenital cholesteatoma of the infratemporal fossa with congenital aural atresia and mastoiditis: a case report

    Directory of Open Access Journals (Sweden)

    Abdel-Aziz Mosaad

    2012-06-01

    Full Text Available Abstract Background Congenital cholesteatoma may be expected in abnormally developed ear, it may cause bony erosion of the middle ear cleft and extend to the infratemporal fossa. We present the first case of congenital cholesteatoma of the infratemporal fossa in a patient with congenital aural atresia that has been complicated with acute mastoiditis. Case presentation A sixteen year old Egyptian male patient presented with congenital cholesteatoma of the infratemporal fossa with congenital aural atresia complicated with acute mastoiditis. Two weeks earlier, the patient suffered pain necessitating hospital admission, magnetic resonance imaging revealed a soft tissue mass in the right infratemporal fossa. On presentation to our institute, Computerized tomography was done as a routine, it proved the diagnosis of mastoiditis, pure tone audiometry showed an air-bone gap of 60 dB. Cortical mastoidectomy was done for treatment of mastoiditis, removal of congenital cholesteatoma was carried out with reconstruction of external auditory canal. Follow-up of the patient for 2 years and 3 months showed a patent, infection free external auditory canal with an air-bone gap has been reduced to 35db. One year after the operation; MRI was done and it showed no residual or recurrent cholesteatoma. Conclusions Congenital cholesteatoma of the infratemporal fossa in cases of congenital aural atresia can be managed safely even if it was associated with mastoiditis. It is an original case report of interest to the speciality of otolaryngology.

  12. Karyotype analysis of a male exhibiting Meckel's diverticulum and aural atresia

    Energy Technology Data Exchange (ETDEWEB)

    Frizzell, B.; Hicks, M.F. (David Lipscomb Univ., Nashville, TN (United States))

    Patau's Syndrome is caused by inheritance of an extra chromosome 13. It is characterized primarily by severe mental retardation, cleft palate, and retarded growth. Most fetuses expressing Patau's Syndrome spontaneously abort, and those that are born usually die before one year. Both Meckel's diverticulum and aural atresia are defects found in patients with Patau's at levels higher than those in the general population. An otherwise asymptomatic male expressing only Meckel's diverticulum and aural atresia has a female sibling whose son expressed Patau's syndrome. Twenty percent of patients with Patau's show a translocation of part of chromosome 13 to another D chromosome. If a translocation were the cause of the expression of Patau's in this family, it is possible that the normal male inherited a balanced translocation and the Patau's male received an unbalanced translocation. A karyotype analysis of the non-Patau's male was done to determine if such a translocation were present.

  13. Aural, visual, and pictorial stimulus formats in false recall.

    Science.gov (United States)

    Beauchamp, Heather M

    2002-12-01

    The present investigation is an initial simultaneous examination of the influence of three stimulus formats on false memories. Several pilot tests were conducted to develop new category associate stimulus lists. 73 women and 26 men (M age=21.1 yr.) were in one of three conditions: they either heard words, were shown words, or were shown pictures highly related to critical nonpresented items. As expected, recall of critical nonpresented stimuli was significantly greater for aural lists than for visually presented words and pictorial images. These findings demonstrate that the accuracy of memory is influenced by the format of the information encoded.

  14. Sound reflection in an acoustic impedance tube terminated with a loudspeaker shunted by a negative impedance converter

    Czech Academy of Sciences Publication Activity Database

    Černík, M.; Mokrý, Pavel

    2012-01-01

    Roč. 21, č. 11 (2012), s. 115016-115016 ISSN 0964-1726 R&D Projects: GA MŠk(CZ) ED2.1.00/03.0079 Institutional research plan: CEZ:AV0Z20430508 Keywords : Sound absorption * electromagnetic shunt damping * electrodynamic loudspeaker * negative impedance converter Subject RIV: BI - Acoustics Impact factor: 2.024, year: 2012

  15. Identification of Aurally Handicapped Children and Methods and Procedures of Developing a Program.

    Science.gov (United States)

    Colorado State Dept. of Education, Denver. Div. of Special Education Services.

    An article on identification of preschool and school age aurally handicapped children and program development by John J. O'Neill precedes discussions of the role of the audiologist in evaluation of these children by Jack A. Willeford, and educational aspects of planning by John J. O'Neill. Three articles are presented on the role of the teacher in…

  16. Analysis of Acoustic Feedback/Echo Cancellation in Multiple-Microphone and Single-Loudspeaker Systems Using a Power Transfer Function Method

    DEFF Research Database (Denmark)

    Guo, Meng; Bo Elmedyb, Thomas; Jensen, Søren Holdt

    2011-01-01

    In this work, we analyze a general multiple-microphone and single-loudspeaker audio processing system, where a multichannel adaptive system is used to cancel the effect of acoustic feedback/echo, and a beamformer processes the feedback/echo canceled signals. We introduce and derive an accurate...

  17. Impact of unilateral conductive hearing loss due to aural atresia on academic performance in children.

    Science.gov (United States)

    Kesser, Bradley W; Krook, Kaelyn; Gray, Lincoln C

    2013-09-01

    This study evaluates the effect of unilateral conductive hearing loss secondary to aural atresia on elementary school children's academic performance. Case control survey and review of audiometric data. One hundred thirty-two surveys were mailed to families of children with aural atresia, and 48 surveys were sent to families of children with unilateral sensorineural hearing loss (SNHL) to identify rates of grade retention, use of any resource, and behavioral problems. Audiometric data of the cohort were tabulated. Of the 40 atresia patients, none repeated a grade, but 65% needed some resources: 12.5% currently use a hearing aid, 32.5% use(d) a frequency-modulated system in school, 47.5% had an Individualized Education Plan, and 45% utilized speech therapy. Compared to the unilateral SNHL group and a cohort of children with unilateral SNHL in an earlier study, children with unilateral atresia were less likely to repeat a grade. Children in both unilateral atresia and SNHL groups were more likely to utilize some resource in the academic setting compared to the unilateral SNHL children in the prior study. Unilateral conductive hearing loss due to aural atresia has an impact on academic performance in children, although not as profound when compared to children with unilateral SNHL. The majority of these children with unilateral atresia utilize resources in the school setting. Parents, educators, and health care professionals should be aware of the impact of unilateral conductive hearing loss and offer appropriate habilitative services. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Requirements for Control Room Computer-Based Procedures for use in Hybrid Control Rooms

    Energy Technology Data Exchange (ETDEWEB)

    Le Blanc, Katya Lee [Idaho National Lab. (INL), Idaho Falls, ID (United States); Oxstrand, Johanna Helene [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey Clark [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    Many plants in the U.S. are currently undergoing control room modernization. The main drivers for modernization are the aging and obsolescence of existing equipment, which typically results in a like-for-like replacement of analogue equipment with digital systems. However, the modernization efforts present an opportunity to employ advanced technology that would not only extend the life, but enhance the efficiency and cost competitiveness of nuclear power. Computer-based procedures (CBPs) are one example of near-term advanced technology that may provide enhanced efficiencies above and beyond like for like replacements of analog systems. Researchers in the LWRS program are investigating the benefits of advanced technologies such as CBPs, with the goal of assisting utilities in decision making during modernization projects. This report will describe the existing research on CBPs, discuss the unique issues related to using CBPs in hybrid control rooms (i.e., partially modernized analog control rooms), and define the requirements of CBPs for hybrid control rooms.

  19. Vortex sound in bass-reflex ports of loudspeakers : part II. a method to estimate the point of separation

    NARCIS (Netherlands)

    Roozen, N.B.; Bockholts, M.; van Eck, P.; Hirschberg, A.

    1998-01-01

    In part I of this paper, the vortex shedding that may occur in a bass-reflex port of a loudspeaker system was discussed. At the Helmholtz frequency of the bass-reflex port, air is pumped in and out at rather high velocities, vortex shedding occurs at the end of the port, and blowing sounds are

  20. A Measure Based on Beamforming Power for Evaluation of Sound Field Reproduction Performance

    DEFF Research Database (Denmark)

    Chang, Ji-ho; Jeong, Cheol-Ho

    2017-01-01

    This paper proposes a measure to evaluate sound field reproduction systems with an array of loudspeakers. The spatially-averaged squared error of the sound pressure between the desired and the reproduced field, namely the spatial error, has been widely used, which has considerable problems in two...... conditions. First, in non-anechoic conditions, room reflections substantially deteriorate the spatial error, although these room reflections affect human localization to a lesser degree. Second, for 2.5-dimensional reproduction of spherical waves, the spatial error increases consistently due...... to the difference in the amplitude decay rate, whereas the degradation of human localization performance is limited. The measure proposed in this study is based on the beamforming powers of the desired and the reproduced fields. Simulation and experimental results show that the proposed measure is less sensitive...

  1. 47 CFR 73.1570 - Modulation levels: AM, FM, TV and Class A TV aural.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Modulation levels: AM, FM, TV and Class A TV... levels: AM, FM, TV and Class A TV aural. (a) The percentage of modulation is to be maintained at as high a level as is consistent with good quality of transmission and good broadcast service, with maximum...

  2. Developing a Vocabulary Size Test Measuring Two Aspects of Receptive Vocabulary Knowledge: Visual versus Aural

    Science.gov (United States)

    Aizawa, Kazumi; Iso, Tatsuo; Nadasdy, Paul

    2017-01-01

    Testing learners' English proficiency is central to university English classes in Japan. This study developed and implemented a set of parallel online receptive aural and visual vocabulary tests that would predict learners' English proficiency. The tests shared the same target words and choices--the main difference was the presentation of the…

  3. On Acoustic Feedback Cancellation Using Probe Noise in Multiple-Microphone and Single-Loudspeaker Systems

    DEFF Research Database (Denmark)

    Guo, Meng; Elmedyb, Thomas Bo; Jensen, Søren Holdt

    2012-01-01

    of the adaptive estimation is significantly decreased when keeping the steady-state error unchanged. The goal of this work is to derive analytic expressions for the system behavior such as convergence rate and steady-state error for a multiple-microphone and single-loudspeaker audio system, where the acoustic...... feedback cancellation is carried out using a probe noise signal. The derived results show how different system parameters and signal properties affect the cancellation performance, and the results explain theoretically the decreased convergence rate. Understanding this is important for making further...

  4. Compensation of the ux modulation distortion using an additional coil in a loudspeaker unit

    DEFF Research Database (Denmark)

    Antonello, Niccoló; Agerkvist, Finn T.

    2014-01-01

    Flux modulation is one of the main causes of distortion in electrodynamic loudspeaker units. A new com- pensation technique that eliminates this type of non-linearity using an additional compensation coil in the speaker unit is presented. An equivalent circuit model of the device including...... the compensation coil is de- rived. The compensation technique consists on feeding the compensation coil and voice coil with ltered versions of the wanted audio signal. Simulations show that a signicant reduction in ux modulation distor- tion can be achieved with this technique. A simple magnetic circuit has been...

  5. Compensation of the flux modulation distortion using an additional coil in a loudspeaker unit

    DEFF Research Database (Denmark)

    Antonello, Niccoló; Agerkvist, Finn T.

    2014-01-01

    the compensation coil is derived. The compensation technique consists on feeding the compensation coil and voice coil with filtered versions of the wanted audio signal. Simulations show that a significant reduction in flux modulation distortion can be achieved with this technique. A simple magnetic circuit has......Flux modulation is one of the main causes of distortion in electrodynamic loudspeaker units. A new compensation technique that eliminates this type of non-linearity using an additional compensation coil in the speaker unit is presented. An equivalent circuit model of the device including...

  6. A Measure Based on Beamforming Power for Evaluation of Sound Field Reproduction Performance

    Directory of Open Access Journals (Sweden)

    Ji-Ho Chang

    2017-03-01

    Full Text Available This paper proposes a measure to evaluate sound field reproduction systems with an array of loudspeakers. The spatially-averaged squared error of the sound pressure between the desired and the reproduced field, namely the spatial error, has been widely used, which has considerable problems in two conditions. First, in non-anechoic conditions, room reflections substantially deteriorate the spatial error, although these room reflections affect human localization to a lesser degree. Second, for 2.5-dimensional reproduction of spherical waves, the spatial error increases consistently due to the difference in the amplitude decay rate, whereas the degradation of human localization performance is limited. The measure proposed in this study is based on the beamforming powers of the desired and the reproduced fields. Simulation and experimental results show that the proposed measure is less sensitive to room reflections and the amplitude decay than the spatial error, which is likely to agree better with the human perception of source localization.

  7. Aural-pharyngeal polyps associated with Cryptosporidium infection in three iguanas (Iguana iguana).

    Science.gov (United States)

    Uhl, E W; Jacobson, E; Bartick, T E; Micinilio, J; Schimdt, R

    2001-03-01

    Cryptosporidium spp. infection was associated with aural-pharyngeal polyps in three iguanas (Iguana iguana). All iguanas were presented for masses protruding from the ear canal, and the disease was characterized by a chronic clinical course. The masses consisted of nests of cystic glands surrounded by abundant fibrous connective tissue and lined by hyperplastic cuboidal to pseudostratified columnar epithelium that was moderately to heavily colonized by cryptosporidial organisms. Electron microscopy revealed that the majority of organisms were trophozoites.

  8. Web based emergency room PACS

    International Nuclear Information System (INIS)

    Cha, Soon Joo; Cheon, Yong Kyung; Choi, Sung Woo Kim

    2005-01-01

    We wished to develop the web based Picture Archiving and Communication System in the emergency room for early decision making in emergency treatment planning at a full PACS Hospital. The program tools were Microsoft Visual Studio 6.0 - Visual C++ 6.0, and the Microsoft SQL 7.0 under the Microsoft Windows 2000 server operation system. The achievement of images was performed by an auto transport program installed in the ER and the radiology department. The average compression rates were 5:1 for CT and MR, and 20:1 for CR with JPEG 2000 lossy compression. All the images were stored on hard disk for 3 months. The patients' information was displayed for 2 weeks for reducing the security risk. For interdepartmental consultation, patient query by patient hospital number was available. Our Web based ER PACS could be useful system for early decision making for treatment planning in the emergency room because it reduces the risk factors for the security of the Web Paces by using a system independent from PACS in the hospital and minimizing the information patients

  9. Web based emergency room PACS

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Soon Joo; Cheon, Yong Kyung; Choi, Sung Woo Kim [Ilsan Paik Hospital, Inje University, Seoul (Korea, Republic of)] (and others)

    2005-07-15

    We wished to develop the web based Picture Archiving and Communication System in the emergency room for early decision making in emergency treatment planning at a full PACS Hospital. The program tools were Microsoft Visual Studio 6.0 - Visual C++ 6.0, and the Microsoft SQL 7.0 under the Microsoft Windows 2000 server operation system. The achievement of images was performed by an auto transport program installed in the ER and the radiology department. The average compression rates were 5:1 for CT and MR, and 20:1 for CR with JPEG 2000 lossy compression. All the images were stored on hard disk for 3 months. The patients' information was displayed for 2 weeks for reducing the security risk. For interdepartmental consultation, patient query by patient hospital number was available. Our Web based ER PACS could be useful system for early decision making for treatment planning in the emergency room because it reduces the risk factors for the security of the Web Paces by using a system independent from PACS in the hospital and minimizing the information patients.

  10. Popularity and Harms of Aural Foreign Bodies: A Descriptive Study of Patients in Baqiyatallah University Hospital, Tehran, Iran.

    Science.gov (United States)

    Taheri, Abolfazl; Mehmandari, Sina Navaei; Shahidi, Mojtaba; Mehdizadeh, Hamidreza; Mirlohi, Seyyed Mohammad Javad; Aref, Nasrin Mohammadi; Avanaki, Mahsa Alborzi; Khosravi, Mohammad Hossein

    2017-12-01

    To evaluate the prevalence of external ear complications among Iranian aural foreign body users attending to otolaryngology clinic of our hospital. In this cross-sectional study patients attending to Otolaryngology clinics of Baqiyatallah hospital were enrolled regardless of their age, gender and reason of attending. Patients between 15 and 60 years of age were included in the present study. Those with positive history of chronic ear diseases, ear surgery, congenital ear disorders, trauma to ear or head and neck region or shock wave trauma were excluded from the study. Demographic information as well as data on chief complaint, educational level, frequency and type of used foreign body and findings of physical examination and Otoscopy by a single otolaryngologist were recorded in a predesigned checklist. Eventually 362 patients (232 male and 130 female) with a mean age of 40.32 ± 16.90 years underwent analysis. Of all patients 244 (67.2%) were using a kind of aural foreign body frequently and Cotton bud was the most popular (63.5%) used foreign body among patients. Drying ear canal was the most common (54.9%) reason of using AFBs among study individuals followed by itching (29.5%) and pyorrhea (11.06%). Also 11 (4.5%) patients were using AFBs as a habit with no specific reason. Itching was the most prevalent symptom reported by both aural foreign body users (78%) and non-users (45.5%); however it was significantly higher among AFB users (p = 0.026). Also hearing loss was significantly more reported by AFB users (p = 0.033). A majority of patients had normal physical examination in both AFB users and non-users group. Inflammation of ear canal was significantly more detected in AFB users (p = 0.004). In addition, rate of right ear wax impaction was higher among AFB users (p = 0.016). In conclusion we realized that 67.2% of patients attending to Otolaryngology clinic of our hospital were using a kind of aural foreign bodies and itching was the most common chief

  11. [Aural Stimulation with Capsaicin Ointment Improved the Swallowing Function in Patients with Dysphagia: Evaluation by the SMRC Scale].

    Science.gov (United States)

    Kondo, Eiji; Jinnouchi, Osamu; Ohnishi, Hiroki; Kawata, Ikuji; Takeda, Noriaki

    2015-11-01

    Cough and swallowing reflexes are important airway-protective mechanisms against aspiration. Angiotensin-converting enzyme (ACE) inhibitors, one of the side effects of which is cough, have been reported to reduce the incidence of aspiration pneumonia in hypertensive patients with stroke. ACE inhibitors have also been reported to improve the swallowing function in post-stroke patients. On the other hand, stimulation of the Arnold nerve, the auricular branch of the vagus, triggers the cough reflex (Arnold's ear-cough reflex). Capsaicin, an agonist of Transient Receptor Potential Vanilloid 1 (TRPV1), has been shown to activate the peripheral sensory C-fibers. Stimulation of the sensory branches of the vagus in the laryngotracheal mucosa with capsaicin induces the cough reflex and has been reported to improve the swallowing function in patients with dysphagia. In our previous study, we showed that aural stimulation of the Arnold nerve with 0.025% capsaicin ointment improved the swallowing function, as evaluated by the endoscopic swallowing score, in 26 patients with dysphagia. In the present study, the video images of swallowing recorded in the previous study were re-evaluated using the SMRC scale by an independent otolaryngologist who was blinded to the information about the patients and the endoscopic swallowing score. The SMRC scale is used to evaluate four aspects of the swallowing function: 1) Sensory: the initiation of the swallowing reflex as assessed by the white-out timing; 2) Motion: the ability to hold blue-dyed water in the oral cavity and induce laryngeal elevation; 3) Reflex: glottal closure and the cough reflex induced by touching the epiglottis or arytenoid with the endoscope; 4) Clearance: pharyngeal clearance of the blue-dyed water after swallowing. Accordingly, we demonstrated that a single application of capsaicin ointment to the external auditory canal of patients with dysphagia significantly improved the R, but not the S, M or C scores, and this

  12. Aural exostoses (surfer's ear) provide vital fossil evidence of an aquatic phase in Man's early evolution.

    Science.gov (United States)

    Rhys Evans, P H; Cameron, M

    2017-11-01

    For over a century, otolaryngologists have recognised the condition of aural exostoses, but their significance and aetiology remains obscure, although they tend to be associated with frequent swimming and cold water immersion of the auditory canal. The fact that this condition is usually bilateral is predictable since both ears are immersed in water. However, why do exostoses only grow in swimmers and why do they grow in the deep bony meatus at two or three constant sites? Furthermore, from an evolutionary point of view, what is or was the purpose and function of these rather incongruous protrusions? In recent decades, paleoanthropological evidence has challenged ideas about early hominid evolution. In 1992 the senior author suggested that aural exostoses were evolved in early hominid Man for protection of the delicate tympanic membrane during swimming and diving by narrowing the ear canal in a similar fashion to other semiaquatic species. We now provide evidence for this theory and propose an aetiological explanation for the formation of exostoses.

  13. Computer vision based room interior design

    Science.gov (United States)

    Ahmad, Nasir; Hussain, Saddam; Ahmad, Kashif; Conci, Nicola

    2015-12-01

    This paper introduces a new application of computer vision. To the best of the author's knowledge, it is the first attempt to incorporate computer vision techniques into room interior designing. The computer vision based interior designing is achieved in two steps: object identification and color assignment. The image segmentation approach is used for the identification of the objects in the room and different color schemes are used for color assignment to these objects. The proposed approach is applied to simple as well as complex images from online sources. The proposed approach not only accelerated the process of interior designing but also made it very efficient by giving multiple alternatives.

  14. Social Media Interruption Affects the Acquisition of Visually, Not Aurally, Acquired Information during a Pathophysiology Lecture

    Science.gov (United States)

    Marone, Jane R.; Thakkar, Shivam C.; Suliman, Neveen; O'Neill, Shannon I.; Doubleday, Alison F.

    2018-01-01

    Poor academic performance from extensive social media usage appears to be due to students' inability to multitask between distractions and academic work. However, the degree to which visually distracted students can acquire lecture information presented aurally is unknown. This study examined the ability of students visually distracted by social…

  15. DML in VIDEO-CONFERENCING APPLICATIONS

    OpenAIRE

    Giske, Mats Andreas

    2012-01-01

    Today's audio in video-conference rooms do not in general have high quality audio standards.Most of the set-ups are PC-Speakers mounted on the wall, with a microphone on the table. With this, strong room modes are often excited from the speakers. When speaking to someone which also have bad equipment, the speech-intelligibility can be really bad. One solution presented with this Master thesis is to improve the loudspeaker set-up by mounting a DML(Distributed Mode Loudspeaker) above and parall...

  16. Optimizing acoustical conditions for speech intelligibility in classrooms

    Science.gov (United States)

    Yang, Wonyoung

    High speech intelligibility is imperative in classrooms where verbal communication is critical. However, the optimal acoustical conditions to achieve a high degree of speech intelligibility have previously been investigated with inconsistent results, and practical room-acoustical solutions to optimize the acoustical conditions for speech intelligibility have not been developed. This experimental study validated auralization for speech-intelligibility testing, investigated the optimal reverberation for speech intelligibility for both normal and hearing-impaired listeners using more realistic room-acoustical models, and proposed an optimal sound-control design for speech intelligibility based on the findings. The auralization technique was used to perform subjective speech-intelligibility tests. The validation study, comparing auralization results with those of real classroom speech-intelligibility tests, found that if the room to be auralized is not very absorptive or noisy, speech-intelligibility tests using auralization are valid. The speech-intelligibility tests were done in two different auralized sound fields---approximately diffuse and non-diffuse---using the Modified Rhyme Test and both normal and hearing-impaired listeners. A hybrid room-acoustical prediction program was used throughout the work, and it and a 1/8 scale-model classroom were used to evaluate the effects of ceiling barriers and reflectors. For both subject groups, in approximately diffuse sound fields, when the speech source was closer to the listener than the noise source, the optimal reverberation time was zero. When the noise source was closer to the listener than the speech source, the optimal reverberation time was 0.4 s (with another peak at 0.0 s) with relative output power levels of the speech and noise sources SNS = 5 dB, and 0.8 s with SNS = 0 dB. In non-diffuse sound fields, when the noise source was between the speaker and the listener, the optimal reverberation time was 0.6 s with

  17. HuRECA: Human Reliability Evaluator for Computer-based Control Room Actions

    International Nuclear Information System (INIS)

    Kim, Jae Whan; Lee, Seung Jun; Jang, Seung Cheol

    2011-01-01

    As computer-based design features such as computer-based procedures (CBP), soft controls (SCs), and integrated information systems are being adopted in main control rooms (MCR) of nuclear power plants, a human reliability analysis (HRA) method capable of dealing with the effects of these design features on human reliability is needed. From the observations of human factors engineering verification and validation experiments, we have drawn some major important characteristics on operator behaviors and design-related influencing factors (DIFs) from the perspective of human reliability. Firstly, there are new DIFs that should be considered in developing an HRA method for computer-based control rooms including especially CBP and SCs. In the case of the computer-based procedure rather than the paper-based procedure, the structural and managerial elements should be considered as important PSFs in addition to the procedural contents. In the case of the soft controllers, the so-called interface management tasks (or secondary tasks) should be reflected in the assessment of human error probability. Secondly, computer-based control rooms can provide more effective error recovery features than conventional control rooms. Major error recovery features for computer-based control rooms include the automatic logic checking function of the computer-based procedure and the information sharing feature of the general computer-based designs

  18. Predicting and auralizing acoustics in classrooms

    DEFF Research Database (Denmark)

    Christensen, Claus Lynge

    2005-01-01

    Although classrooms have fairly simple geometries, this type of room is known to cause problems when trying to predict their acoustics using room acoustics computer modeling. Some typical features from a room acoustics point of view are: Parallel walls, low ceilings (the rooms are flat), uneven...

  19. The Effects of Aural versus Notated Instructional Materials on Achievement and Self-Efficacy in Jazz Improvisation

    Science.gov (United States)

    Watson, Kevin E.

    2010-01-01

    The purpose of the present study was to investigate the effects of aural versus notated pedagogical materials on achievement and self-efficacy in instrumental jazz improvisation performance. A secondary purpose of this study was to investigate how achievement and self-efficacy may be related to selected experience variables. The sample for the…

  20. Affordable headphones for accessible screening audiometry: An evaluation of the Sennheiser HD202 II supra-aural headphone.

    Science.gov (United States)

    Van der Aerschot, Mathieu; Swanepoel, De Wet; Mahomed-Asmail, Faheema; Myburgh, Herman Carel; Eikelboom, Robert Henry

    2016-11-01

    Evaluation of the Sennheiser HD 202 II supra-aural headphones as an alternative headphone to enable more affordable hearing screening. Study 1 measured the equivalent threshold sound pressure levels (ETSPL) of the Sennheiser HD 202 II. Study 2 evaluated the attenuation of the headphones. Study 3 determined headphone characteristics by analyzing the total harmonic distortion (THD), frequency response and force of the headband. Twenty-five participants were included in study 1 and 15 in study 2 with ages ranging between 18 and 25. No participants were involved in study 3. The Sennheiser HD 202 II ETSPLs (250-16000 Hz) showed no significant effects on ETSPL for ear laterality, gender or age. Attenuation was not significantly different (p > 0.01) to TDH 39 except at 8000 Hz (p 3%. Sennheiser HD 202 II supra-aural headphones can be used as an affordable headphone for screening audiometry provided reported MPANLs, maximum intensities and ETSPL values are employed.

  1. In vitro susceptibility of aural isolates of Pseudomonas aeruginosa to commonly used ototopical antibiotics.

    Science.gov (United States)

    Dohar, J E; Kenna, M A; Wadowsky, R M

    1996-03-01

    The choice of antimicrobial agents used to treat Pseudomonas aeruginosa infections of the ear is quite empiric. Yet in spite of this, very little has been published examining susceptibility patterns of aural isolates of P. aeruginosa. Recently, increasing concern has emerged over the development of resistance to many of the commonly used ototopical preparations with activity against P. aeruginosa. This concern stems from the fact that these preparations have been in use for a long time, and P. aeruginosa is known to develop resistance fairly readily. We prospectively studied the susceptibilities of aural isolates of P. aeruginosa in 231 consecutive children who were seen in the outpatient Pediatric Otolaryngology Department at Children's Hospital of Pittsburgh during the years 1992 and 1993. The agents tested included neomycin, polymyxin B, colistin, and norfloxacin. We found that only 17.8% of the isolates were sensitive to neomycin, as opposed to > 95% for each of the other agents tested (polymyxin B, 99.6%; colistin, 97.4%; and norfloxacin, 98.3%). This difference proved to be statistically significant (p < 0.05). Given the concern of aminoglycoside-induced ototoxicity and the high rate of neomycin resistance, we believe that further investigation of other alternative ototopic agents with activity against P. aeruginosa is warranted.

  2. Game-based training environment for nuclear plant control room

    International Nuclear Information System (INIS)

    Hung Tamin; Sun Tienlung; Yang Chihwei; Yang Lichen; Cheng Tsungchieh; Wang Jyhgang

    2011-01-01

    Nuclear power plant's safety is very important problem. In this very conscientious environment if operator has a little mistake, they may threaten with many people influence their safety. Therefore, operating training of control room is very important. However, the operator training is in limited space and time. Each operator must go to simulative control room do some training. If we can let each trainee having more time to do training and does not go to simulative control room. It may have some advantages for trainee. Moreover, in the traditional training ways, each operator may through the video, teaching manual or through the experienced instructor to learn the knowledge. This training way may let operator feel bored and stressful. So, in this paper aims, we hope utilizing virtual reality technology developing a game-based virtual training environment of control room. Finally, we will use presence questionnaire evaluating realism and feasibility of our virtual training environment. Expecting this initial concept of game-based virtual training environment can attract trainees having more learning motivation to do training in off-hour. (author)

  3. Pilot study: Exposure and materiality of the secondary room and its impact in the impulse response of coupled-volume concert halls

    Science.gov (United States)

    Ermann, Michael; Johnson, Marty E.

    2002-05-01

    What does one room sound like when it is partially exposed to another (acoustically coupled)? More specifically, this research aims to quantify how operational and design decisions impact aural impressions in the design of concert halls with acoustical coupling. By adding a second room to a concert hall, and designing doors to control the sonic transparency between the two rooms, designers can create a new, coupled acoustic. Concert halls use coupling to achieve a variable, longer, and distinct reverberant quality for their musicians and listeners. For this study, a coupled-volume shoebox concert hall was conceived with a fixed geometric volume, form, and primary-room sound absorption. Aperture size and secondary-room sound-absorption levels were established as variables. Statistical analysis of sound decay in this simulated hall suggests a highly sensitive relationship between the double-sloped condition and (1) Architectural composition, as defined by the aperture size exposing the chamber and (2) Materiality, as defined by the sound absorbance in the coupled volume. Preliminary calculations indicate that the double-sloped sound decay condition only appears when the total aperture area is less than 1.5% of the total shoebox surface area and the average absorption coefficient of the coupled volume is less than 0.07.

  4. How to Design and Equip a Mentalization-Based Play Therapy Room.

    Science.gov (United States)

    Rüth, Ulrich; Holch, Astrid

    2018-01-01

    Designing and equipping a play therapy room as a differentiated tool in a psychodynamic approach to child psychotherapy is seldom discussed. This article sketches out the equipment and furnishing of a play therapy room to be used for mentalization-based psychodynamic psychotherapy and gives examples of the use of such a room in practice.

  5. Aural hygiene practices among underprivileged children of Delhi.

    Science.gov (United States)

    Bhat, A; Ray, T K; Sahni, J K

    2015-01-01

    Though ear hygiene is important for proper hearing, it is usually neglected. Improper ear care practices may have serious consequences such as loss of hearing. In childhood, loss of hearing may affect learning and development. There is scarcity of information on ear care practices in the community in India. We aimed to ascertain the magnitude of problems related to aural hygiene and assess ear care practices among children of schoolgoing age in a resettlement colony of Delhi. A cross-sectional community-based survey was done among 1398 children 5-14 years of age. The houses were selected by systematic random sampling and all eligible children in the selected house were interviewed and examined. The data were analysed using SPSS version 12 and chi-square test was used to ascertain significance between two variables. Almost two-thirds (60%; 834) of the children gave a history of themselves or an elder cleaning the ear using unhealthy methods. Earbuds were used by 21.7% (304) of children. Match and broomsticks were used for cleaning by 18.3% (256) and 3% (43) of children, respectively. One hundred and fifty-nine children (11.3%) were applying oil to clean the ear canal. Ear cleaning with unhealthy means was significantly higher (56% v. 44%, pmiddle ear infection (p<0.001). A majority of children practised unhealthy/ not recommended methods for cleaning their ear. There is a need to raise awareness about healthy ear cleaning practices in the community. Copyright 2015, NMJI.

  6. The modality-switch effect: Visually and aurally presented prime sentences activate our senses

    Directory of Open Access Journals (Sweden)

    Elisa eScerrati

    2015-10-01

    Full Text Available Verifying different sensory modality properties for concepts results in a processing cost known as the Modality-Switch Effect. It has been argued that this cognitive cost is the result of a perceptual simulation. This paper extends this argument and reports an experiment investigating whether the effect is the result of an activation of sensory information which can also be triggered by perceptual linguistically described stimuli. Participants were first exposed to a prime sentence describing a light or a sound’s perceptual property (e.g. The light is flickering, The sound is echoing, then required to perform a property-verification task on a target sentence (e.g. Butter is yellowish, Leaves rustle. The content modalities of the prime and target sentences could be compatible (i.e. in the same modality: e.g. visual-visual or not (i.e. in different modalities. Crucially, we manipulated the stimuli’s presentation modality such that half of the participants was faced with written sentences while the other half was faced with aurally presented sentences. Results show a cost when two different modalities alternate, compared to when the same modality is repeated with both visual and aural stimuli presentations. This result supports the embodied and grounded cognition view which claims that conceptual knowledge is grounded into the perceptual system. Specifically, this evidence suggests that sensory modalities can be pre-activated through the simulation of either read or listened linguistic stimuli describing visual or acoustic perceptual properties.

  7. Complementing Operating Room Teaching With Video-Based Coaching.

    Science.gov (United States)

    Hu, Yue-Yung; Mazer, Laura M; Yule, Steven J; Arriaga, Alexander F; Greenberg, Caprice C; Lipsitz, Stuart R; Gawande, Atul A; Smink, Douglas S

    2017-04-01

    Surgical expertise demands technical and nontechnical skills. Traditionally, surgical trainees acquired these skills in the operating room; however, operative time for residents has decreased with duty hour restrictions. As in other professions, video analysis may help maximize the learning experience. To develop and evaluate a postoperative video-based coaching intervention for residents. In this mixed methods analysis, 10 senior (postgraduate year 4 and 5) residents were videorecorded operating with an attending surgeon at an academic tertiary care hospital. Each video formed the basis of a 1-hour one-on-one coaching session conducted by the operative attending; although a coaching framework was provided, participants determined the specific content collaboratively. Teaching points were identified in the operating room and the video-based coaching sessions; iterative inductive coding, followed by thematic analysis, was performed. Teaching points made in the operating room were compared with those in the video-based coaching sessions with respect to initiator, content, and teaching technique, adjusting for time. Among 10 cases, surgeons made more teaching points per unit time (63.0 vs 102.7 per hour) while coaching. Teaching in the video-based coaching sessions was more resident centered; attendings were more inquisitive about residents' learning needs (3.30 vs 0.28, P = .04), and residents took more initiative to direct their education (27% [198 of 729 teaching points] vs 17% [331 of 1977 teaching points], P based coaching is a novel and feasible modality for supplementing intraoperative learning. Objective evaluation demonstrates that video-based coaching may be particularly useful for teaching higher-level concepts, such as decision making, and for individualizing instruction and feedback to each resident.

  8. Anatomic measurements of the posterior tympanum related to the round window vibroplasty in congenital aural atresia and stenosis patients.

    Science.gov (United States)

    Chen, Keguang; Yin, Dongming; Lyu, Huiying; Yang, Lin; Zhang, Tianyu; Dai, Peidong

    2016-01-01

    With the aggravation of the external auditory canal malformation, the size of extra-niche fossa became smaller, providing concrete data and valuable information for the better design, selecting and safer implantation of the transducer in the area of round window niche. Three-dimensional measurements and assessments before surgery might be helpful for a safer surgical approach and implantation of a vibrant soundbridge. The aim of this study was to investigate whether differences exist in the morphology of the posterior tympanum related to the round window vibroplasty among congenital aural atresia (CAA), congenital aural stenosis (CAS), and a normal control group, and to analyze its effect on the round window implantation of vibrant soundbridge. CT images of 10 normal subjects (20 ears), 27 CAS patients (30 ears), and 25 CAA patients (30 ears) were analyzed. The depth and the size of outside fossa of round window niche related to the round window vibroplasty (extra-niche fossa)and the distances between the center of round window niche and extra-niche fossa were calculated based on three-dimensional reconstruction using mimics software. Finally, the data were analyzed statistically. The size of extra-niche fossa in the atresia group was smaller than in the stenosis group (p < 0.05); furthermore, the size of extra-niche fossa in the stenosis group was smaller than that of the control group (p < 0.05). There was no statistically significant difference of the depth of extra-niche fossa among different groups.

  9. Wideband aural acoustic absorbance predicts conductive hearing loss in children.

    Science.gov (United States)

    Keefe, Douglas H; Sanford, Chris A; Ellison, John C; Fitzpatrick, Denis F; Gorga, Michael P

    2012-12-01

    This study tested the hypothesis that wideband aural absorbance predicts conductive hearing loss (CHL) in children medically classified as having otitis media with effusion. Absorbance was measured in the ear canal over frequencies from 0.25 to 8 kHz at ambient pressure or as a swept tympanogram. CHL was defined using criterion air-bone gaps of 20, 25, and 30 dB at octaves from 0.25 to 4 kHz. A likelihood-ratio predictor of CHL was constructed across frequency for ambient absorbance, and across frequency and pressure for absorbance tympanometry. Performance was evaluated at individual frequencies and for any frequency at which a CHL was present. Absorbance and conventional 0.226-kHz tympanograms were measured in children of age three to eight years with CHL and with normal hearing. Absorbance was smaller at frequencies above 0.7 kHz in the CHL group than the control group. Based on the area under the receiver operating characteristic curve, wideband absorbance in ambient and tympanometric tests were significantly better predictors of CHL than tympanometric width, the best 0.226-kHz predictor. Accuracies of ambient and tympanometric wideband absorbance did not differ. Absorbance accurately predicted CHL in children and was more accurate than conventional 0.226-kHz tympanometry.

  10. Auralization of Tonal Rotor Noise Components of a Quadcopter Flyover

    Science.gov (United States)

    Christian, Andrew W.; Boyd, David D.; Zawodny, Nikolas S.; Rizzi, Stephen A.

    2015-01-01

    The capabilities offered by small unmanned vertical lift aerial vehicles, for example, quadcopters, continue to captivate entrepreneurs across the private, public, and civil sectors. As this industry rapidly expands, the public will be exposed to these devices (and to the noise these devices generate) with increasing frequency and proximity. Accordingly, an assessment of the human response to these machines will be needed shortly by decision makers in many facets of this burgeoning industry, from hardware manufacturers all the way to government regulators. One factor of this response is that of the annoyance to the noise that is generated by these devices. This paper presents work currently being pursued by NASA toward this goal. First, physics-based (CFD) predictions are performed on a single isolated rotor typical of these devices. The result of these predictions are time records of the discrete tonal components of the rotor noise. These time records are calculated for a number of points that appear on a lattice of locations spread over the lower hemisphere of the rotor. The source noise is then generated by interpolating between these time records. The sound from four rotors are combined and simulated-propagation techniques are used to produce complete flyover auralizations.

  11. Reproduction of nearby sound sources using higher-order ambisonics with practical loudspeaker arrays

    DEFF Research Database (Denmark)

    Favrot, Sylvain Emmanuel; Buchholz, Jörg

    2012-01-01

    the impact of two existing and a new proposed regularization function on the reproduced sound fields and on the main auditory cue for nearby sound sources outside the median plane, i.e, low-frequencies interaural level differences (ILDs). The proposed regularization function led to a better reproduction......In order to reproduce nearby sound sources with distant loudspeakers to a single listener, the near field compensated (NFC) method for higher-order Ambisonics (HOA) has been previously proposed. In practical realization, this method requires the use of regularization functions. This study analyzes...... of point source sound fields compared to existing regularization functions for NFC-HOA. Measurements in realistic playback environments showed that, for very close sources, significant ILDs for frequencies above about 250 Hz can be reproduced with NFC-HOA and the proposed regularization function whereas...

  12. Aural stimulation with capsaicin ointment improved swallowing function in elderly patients with dysphagia: a randomized, placebo-controlled, double-blind, comparative study.

    Science.gov (United States)

    Kondo, Eiji; Jinnouchi, Osamu; Nakano, Seiichi; Ohnishi, Hiroki; Kawata, Ikuji; Okamoto, Hidehiko; Takeda, Noriaki

    2017-01-01

    The aim of this study was to assess whether aural stimulation with ointment containing capsaicin improves swallowing function in elderly patients with dysphagia. A randomized, placebo-controlled, double-blind, comparative study. Secondary hospital. Twenty elderly dysphagic patients with a history of cerebrovascular disorder or Parkinson's disease were randomly divided into two groups: 10 receiving aural stimulation with 0.025% capsaicin ointment and 10 stimulated with placebo. The ointments were applied to the external auditory canal with a cotton swab. Then, swallowing of a bolus of blue-dyed water was recorded using transnasal videoendoscopy, and the swallowing function was evaluated according to both endoscopic swallowing scoring and Sensory-Motor-Reflex-Clearance (SMRC) scale. The sum of endoscopic swallowing scores was significantly decreased 30 and 60 min after a single administration in patients treated with capsaicin, but not with placebo. Reflex score, but not Sensory, Motion and Clearance scores, of the SMRC scale was significantly increased 5, 30 and 60 min after single administration in patients treated with capsaicin, but not with placebo. No patient showed signs of adverse effects. As capsaicin is an agonist of the transient receptor potential vanilloid 1 (TRPV1), these findings suggest that improvement of the swallowing function, especially glottal closure and cough reflexes, in elderly dysphagic patients was due to TRPV1-mediated aural stimulation of vagal Arnold's nerve with capsaicin, but not with a nonspecific mechanical stimulation with a cotton swab.

  13. Virtual environment display for a 3D audio room simulation

    Science.gov (United States)

    Chapin, William L.; Foster, Scott

    1992-06-01

    Recent developments in virtual 3D audio and synthetic aural environments have produced a complex acoustical room simulation. The acoustical simulation models a room with walls, ceiling, and floor of selected sound reflecting/absorbing characteristics and unlimited independent localizable sound sources. This non-visual acoustic simulation, implemented with 4 audio ConvolvotronsTM by Crystal River Engineering and coupled to the listener with a Poihemus IsotrakTM, tracking the listener's head position and orientation, and stereo headphones returning binaural sound, is quite compelling to most listeners with eyes closed. This immersive effect should be reinforced when properly integrated into a full, multi-sensory virtual environment presentation. This paper discusses the design of an interactive, visual virtual environment, complementing the acoustic model and specified to: 1) allow the listener to freely move about the space, a room of manipulable size, shape, and audio character, while interactively relocating the sound sources; 2) reinforce the listener's feeling of telepresence into the acoustical environment with visual and proprioceptive sensations; 3) enhance the audio with the graphic and interactive components, rather than overwhelm or reduce it; and 4) serve as a research testbed and technology transfer demonstration. The hardware/software design of two demonstration systems, one installed and one portable, are discussed through the development of four iterative configurations. The installed system implements a head-coupled, wide-angle, stereo-optic tracker/viewer and multi-computer simulation control. The portable demonstration system implements a head-mounted wide-angle, stereo-optic display, separate head and pointer electro-magnetic position trackers, a heterogeneous parallel graphics processing system, and object oriented C++ program code.

  14. Oral Communication Development in Severe to Profound Hearing Impaired Children After Receiving Aural Habilitation

    Directory of Open Access Journals (Sweden)

    Soleimani Farin

    2009-10-01

    Full Text Available Communication, cognition, language, and speech are interrelated and develop together. It should come as no surprise to us that the key to intervention with deaf children is to establish, as early as possible, a functional communication system for the child and the parents. Early intervention programs need to be multidisciplinary, technologically sound and most important, it should take cognizance of the specific context (community, country in which the child and family function. The main aim of this study was to obtain oral communication development regarding current status of the intervention (aural habilitation and speech therapyfor children with severe to profound hearing impairment in Iran. A prospective longitudinal study was undertaken on a consecutive group of children with severe to profound deafness. Nine severe to profound hearing-impaired children out of the primer 42 cases, who were detected below two years old, had been selected in the previous study to receive aural habilitation. The average of their speech intelligibility scores was near 70% at age 6, which was accounted as poor oral communication and only two of them were able to communicate by spoken language. An integrated intervention services continued again for one year and their oral communication skill was assessed by their speech intelligibility. The intelligibility test of children was recorded on audio-tape, when they read 10 questions such as where is your home. This can be answered only in one word. Each tape was presented to10 normal hearing listeners, and their task was to write down, the answers in Persian orthography. At the beginning (at age 6 the average speech intelligibility score of these children was 72% and only two of them had score of 90% and 100%. At age 7, all of the severe groups were over 90%, and only two profound ones achieved the score of 48% and 62%. All of severe groups develop oral communication, but profound ones had a semi-intelligible speech

  15. Virtual reality in the operating room of the future.

    Science.gov (United States)

    Müller, W; Grosskopf, S; Hildebrand, A; Malkewitz, R; Ziegler, R

    1997-01-01

    In cooperation with the Max-Delbrück-Centrum/Robert-Rössle-Klinik (MDC/RRK) in Berlin, the Fraunhofer Institute for Computer Graphics is currently designing and developing a scenario for the operating room of the future. The goal of this project is to integrate new analysis, visualization and interaction tools in order to optimize and refine tumor diagnostics and therapy in combination with laser technology and remote stereoscopic video transfer. Hence, a human 3-D reference model is reconstructed using CT, MR, and anatomical cryosection images from the National Library of Medicine's Visible Human Project. Applying segmentation algorithms and surface-polygonization methods a 3-D representation is obtained. In addition, a "fly-through" the virtual patient is realized using 3-D input devices (data glove, tracking system, 6-DOF mouse). In this way, the surgeon can experience really new perspectives of the human anatomy. Moreover, using a virtual cutting plane any cut of the CT volume can be interactively placed and visualized in realtime. In conclusion, this project delivers visions for the application of effective visualization and VR systems. Commonly known as Virtual Prototyping and applied by the automotive industry long ago, this project shows, that the use of VR techniques can also prototype an operating room. After evaluating design and functionality of the virtual operating room, MDC plans to build real ORs in the near future. The use of VR techniques provides a more natural interface for the surgeon in the OR (e.g., controlling interactions by voice input). Besides preoperative planning future work will focus on supporting the surgeon in performing surgical interventions. An optimal synthesis of real and synthetic data, and the inclusion of visual, aural, and tactile senses in virtual environments can meet these requirements. This Augmented Reality could represent the environment for the surgeons of tomorrow.

  16. To improve training methods in an engine room simulator-based training

    OpenAIRE

    Lin, Chingshin

    2016-01-01

    The simulator based training are used widely in both industry and school education to reduce the accidents nowadays. This study aims to suggest the improved training methods to increase the effectiveness of engine room simulator training. The effectiveness of training in engine room will be performance indicators and the self-evaluation by participants. In the first phase of observation, the aim is to find out the possible shortcomings of current training methods based on train...

  17. 3D visualization based customer experiences of nuclear plant control room

    International Nuclear Information System (INIS)

    Sun Tienlung; Chou Chinmei; Hung Tamin; Cheng Tsungchieh; Yang Chihwei; Yang Lichen

    2011-01-01

    This paper employs virtual reality (VR) technology to develop an interactive virtual nuclear plant control room in which the general public could easily walk into the 'red zone' and play with the control buttons. The VR-based approach allows deeper and richer customer experiences that the real nuclear plant control room could not offer. When people know more about the serious process control procedures enforced in the nuclear plant control room, they will appropriate more about the safety efforts imposed by the nuclear plant and become more comfortable about the nuclear plant. The virtual nuclear plant control room is built using a 3D game development tool called Unity3D. The 3D scene is connected to a nuclear plant simulation system through Windows API programs. To evaluate the usability of the virtual control room, an experiment will be conducted to see how much 'immersion' the users could feel when they played with the virtual control room. (author)

  18. IMPLEMENTATION OF ACTIVITY BASED ANALYSIS METHOD COSTING SYSTEM IN PRICING COST OF ROOMS IN HOTEL DYNASTY MAKASSAR

    Directory of Open Access Journals (Sweden)

    Muh Nur Hatta

    2017-06-01

    Full Text Available The purpose of this study is to fulfill one of the final project now where Thesis research was held in April to June, 2016. This study aims to know the differences in the calculation of the cost of the room by using a conventional system using activity-based costing (ABC system. method analysis is using descriptive method of analysis of the cost of the hotel this time, set the conventional method and then comparing the cost of a hotel room based activity based result costing. study showed that of calculating the cost of a hotel room by using activity based costing, when compared with the cost of hotel rooms used by the activity based costing Dynasty then give the results in standard rooms, deluxe, suites and family give results the calculation of which is smaller than the cost of the rooms which have been determined by the hotel management. That is, with the difference in price for a Standard room IDR. 58024.84. For a Deluxe room IDR. 175,411.58. For room Suite IDR. 99. 034,88. Family rooms and for IDR. 100,045.60. While in the room Executive Suite / Pent House Activity Based Costing calculation result is greater than the cost of the rooms which have been determined by the hotel management. That is, with the difference amounting to IDR. 368,096.17. The difference in price is due to the method of Activity Based Costing,The overhead on each product is charged to a lot of cost driver. Thus, in the Activity Based Costing method is able to allocate activity costs to each room is right by the consumption of each activity.

  19. Self-reported outcomes of aural rehabilitation for adult hearing aid users in a developing South African context

    Directory of Open Access Journals (Sweden)

    Elaine Pienaar

    2010-12-01

    Full Text Available Hearing impairment has far reaching consequences for affected individuals, in terms of quality of life indicators. In a developing South African context the hearing impaired population is faced with limited aural rehabilitation services. This study evaluated self-reported outcomes of aural rehabilitation in a group of adults in the public healthcare sector with a standardized outcomes measurement tool (IOI-HA. Sixty-one respondents participated (44% males; 56% females, with a mean age of 69.7 years. Results revealed that the majority of respondents experienced favourable outcomes in all domains of the inventory comprising of: daily use of hearing aids, benefits provided by hearing aids, residual activity limitation, satisfaction with hearing aids, residual participation restriction, impact of hearing difficulties on others, and changes in quality of life. Statistically significant relationships were obtained between the daily use of hearing aids, the degree of hearing loss, and the type of hearing aids fitted, as well as the benefits received from hearing aids in difficult listening environments (p < 0.05. Despite challenges of developing contexts, the mean scores distribution compared positively to similar reports from developed countries. Outcomes of improved quality of life emphasize the importance of providing affordable hearing aids and services to all hearing impaired individuals in South Africa.

  20. Design and implementation of a microprocessor based room ...

    African Journals Online (AJOL)

    This paper describes the development of a microprocessor based room illumination control system that offers advantage of improved efficiency in the use of electrical energy and reduced cost of electricity over manually controlled lighting systems. This system is developed to regulate the intensity of light from direct current ...

  1. Equivalent threshold sound pressure levels (ETSPL) for Sennheiser HDA 280 supra-aural audiometric earphones in the frequency range 125 Hz to 8000 Hz.

    Science.gov (United States)

    Poulsen, Torben; Oakley, Sebastian

    2009-05-01

    Hearing threshold sound pressure levels were measured for the Sennheiser HDA 280 audiometric earphone. Hearing thresholds were measured for 25 normal-hearing test subjects at the 11 audiometric test frequencies from 125 Hz to 8000 Hz. Sennheiser HDA 280 is a supra-aural earphone that may be seen as a substitute for the classical Telephonics TDH 39. The results are given as the equivalent threshold sound pressure level (ETSPL) measured in an acoustic coupler specified in IEC 60318-3. The results are in good agreement with an independent investigation from PTB, Braunschweig, Germany. From acoustic laboratory measurements ETSPL values are calculated for the ear simulator specified in IEC 60318-1. Fitting of earphone and coupler is discussed. The data may be used for a future update of the RETSPL standard for supra-aural audiometric earphones, ISO 389-1.

  2. Metal nanoparticle film-based room temperature Coulomb transistor.

    Science.gov (United States)

    Willing, Svenja; Lehmann, Hauke; Volkmann, Mirjam; Klinke, Christian

    2017-07-01

    Single-electron transistors would represent an approach to developing less power-consuming microelectronic devices if room temperature operation and industry-compatible fabrication were possible. We present a concept based on stripes of small, self-assembled, colloidal, metal nanoparticles on a back-gate device architecture, which leads to well-defined and well-controllable transistor characteristics. This Coulomb transistor has three main advantages. By using the scalable Langmuir-Blodgett method, we combine high-quality chemically synthesized metal nanoparticles with standard lithography techniques. The resulting transistors show on/off ratios above 90%, reliable and sinusoidal Coulomb oscillations, and room temperature operation. Furthermore, this concept allows for versatile tuning of the device properties such as Coulomb energy gap and threshold voltage, as well as period, position, and strength of the oscillations.

  3. Room acoustics modeling using a point-cloud representation of the room geometry

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    Room acoustics modeling is usually based on the room geometry that is parametrically described prior to a sound transmission calculation. This is a highly room-specific task and rather time consuming if a complex geometry is to be described. Here, a run time generic method for an arbitrary room...... geometry acquisition is presented. The method exploits a depth sensor of the Kinect device that provides a point based information of a scanned room interior. After post-processing of the Kinect output data, a 3D point-cloud model of the room is obtained. Sound transmission between two selected points...... level of user immersion by a real time acoustical simulation of a dynamic scenes....

  4. A room temperature light source based on silicon nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Lo Faro, M.J. [CNR-IPCF, Istituto per i Processi Chimico-Fisici, V. le F. Stagno D' Alcontres 37, 98158 Messina (Italy); MATIS CNR-IMM, Istituto per la Microelettronica e Microsistemi, Via Santa Sofia 64, 95123 Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Via Santa Sofia 64, 95123 Catania (Italy); D' Andrea, C. [MATIS CNR-IMM, Istituto per la Microelettronica e Microsistemi, Via Santa Sofia 64, 95123 Catania (Italy); Messina, E.; Fazio, B. [CNR-IPCF, Istituto per i Processi Chimico-Fisici, V. le F. Stagno D' Alcontres 37, 98158 Messina (Italy); Musumeci, P. [Dipartimento di Fisica e Astronomia, Università di Catania, Via Santa Sofia 64, 95123 Catania (Italy); Franzò, G. [MATIS CNR-IMM, Istituto per la Microelettronica e Microsistemi, Via Santa Sofia 64, 95123 Catania (Italy); Gucciardi, P.G.; Vasi, C. [CNR-IPCF, Istituto per i Processi Chimico-Fisici, V. le F. Stagno D' Alcontres 37, 98158 Messina (Italy); Priolo, F. [MATIS CNR-IMM, Istituto per la Microelettronica e Microsistemi, Via Santa Sofia 64, 95123 Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Via Santa Sofia 64, 95123 Catania (Italy); Scuola Superiore di Catania, Via Valdisavoia 9, 95123 Catania (Italy); Iacona, F. [MATIS CNR-IMM, Istituto per la Microelettronica e Microsistemi, Via Santa Sofia 64, 95123 Catania (Italy); Irrera, A., E-mail: irrera@me.cnr.it [CNR-IPCF, Istituto per i Processi Chimico-Fisici, V. le F. Stagno D' Alcontres 37, 98158 Messina (Italy)

    2016-08-31

    We synthesized ultrathin Si nanowires (NWs) by metal assisted chemical wet etching, using a very thin discontinuous Au layer as precursor for the process. A bright room temperature emission in the visible range due to electron–hole recombination in quantum confined Si NWs is reported. A single walled carbon nanotube (CNT) suspension was prepared and dispersed in Si NW samples. The hybrid Si NW/CNT system exhibits a double emission at room temperature, both in the visible (due to Si NWs) and the IR (due to CNTs) range, thus demonstrating the realization of a low-cost material with promising perspectives for applications in Si-based photonics. - Highlights: • Synthesis of ultrathin Si nanowires (NWs) by metal-assisted chemical etching • Synthesis of NW/carbon nanotube (CNT) hybrid systems • Structural characterization of Si NWs and Si NW/CNT • Room temperature photoluminescence (PL) properties of Si NWs and of Si NW/CNT • Tuning of the PL properties of the Si NW/CNT hybrid system.

  5. Metal nanoparticle film–based room temperature Coulomb transistor

    Science.gov (United States)

    Willing, Svenja; Lehmann, Hauke; Volkmann, Mirjam; Klinke, Christian

    2017-01-01

    Single-electron transistors would represent an approach to developing less power–consuming microelectronic devices if room temperature operation and industry-compatible fabrication were possible. We present a concept based on stripes of small, self-assembled, colloidal, metal nanoparticles on a back-gate device architecture, which leads to well-defined and well-controllable transistor characteristics. This Coulomb transistor has three main advantages. By using the scalable Langmuir-Blodgett method, we combine high-quality chemically synthesized metal nanoparticles with standard lithography techniques. The resulting transistors show on/off ratios above 90%, reliable and sinusoidal Coulomb oscillations, and room temperature operation. Furthermore, this concept allows for versatile tuning of the device properties such as Coulomb energy gap and threshold voltage, as well as period, position, and strength of the oscillations. PMID:28740864

  6. Virtual Seminar Room

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Fosgerau, Anders; Hansen, Peter Søren Kirk

    1999-01-01

    The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented.......The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented....

  7. Efficient Multichannel NLMS Implementation for Acoustic Echo Cancellation

    Directory of Open Access Journals (Sweden)

    Schüldt Christian

    2007-01-01

    Full Text Available An acoustic echo cancellation structure with a single loudspeaker and multiple microphones is, from a system identification perspective, generally modelled as a single-input multiple-output system. Such a system thus implies specific echo-path models (adaptive filter for every loudspeaker to microphone path. Due to the often large dimensionality of the filters, which is required to model rooms with standard reverberation time, the adaptation process can be computationally demanding. This paper presents a selective updating normalized least mean square (NLMS-based method which reduces complexity to nearly half in practical situations, while showing superior convergence speed performance as compared to conventional complexity reduction schemes. Moreover, the method concentrates the filter adaptation to the filter which is most misadjusted, which is a typically desired feature.

  8. Efficient Multichannel NLMS Implementation for Acoustic Echo Cancellation

    Directory of Open Access Journals (Sweden)

    Fredric Lindstrom

    2007-02-01

    Full Text Available An acoustic echo cancellation structure with a single loudspeaker and multiple microphones is, from a system identification perspective, generally modelled as a single-input multiple-output system. Such a system thus implies specific echo-path models (adaptive filter for every loudspeaker to microphone path. Due to the often large dimensionality of the filters, which is required to model rooms with standard reverberation time, the adaptation process can be computationally demanding. This paper presents a selective updating normalized least mean square (NLMS-based method which reduces complexity to nearly half in practical situations, while showing superior convergence speed performance as compared to conventional complexity reduction schemes. Moreover, the method concentrates the filter adaptation to the filter which is most misadjusted, which is a typically desired feature.

  9. Evaluation of a Loudspeaker-Based Virtual Acoustic Environment for Investigating sound-field auditory steady-state responses

    DEFF Research Database (Denmark)

    Zapata-Rodriguez, Valentina; Marbjerg, Gerd Høy; Brunskog, Jonas

    2017-01-01

    Measuring sound-field auditory steady-state responses (ASSR) is a promising new objective clinical procedure for hearing aid fitting validation, particularly for infants who cannot respond to behavioral tests. In practice, room acoustics of non-anechoic test rooms can heavily influence the audito...... tool PARISM (Phased Acoustical Radiosity and Image Source Method) and validated through measurements. This study discusses the limitations of the system and the potential improvements needed for a more realistic sound-field ASSR simulation....

  10. The Single- and Multichannel Audio Recordings Database (SMARD)

    DEFF Research Database (Denmark)

    Nielsen, Jesper Kjær; Jensen, Jesper Rindom; Jensen, Søren Holdt

    2014-01-01

    A new single- and multichannel audio recordings database (SMARD) is presented in this paper. The database contains recordings from a box-shaped listening room for various loudspeaker and array types. The recordings were made for 48 different configurations of three different loudspeakers and four...... different microphone arrays. In each configuration, 20 different audio segments were played and recorded ranging from simple artificial sounds to polyphonic music. SMARD can be used for testing algorithms developed for numerous application, and we give examples of source localisation results....

  11. Operating room management and operating room productivity: the case of Germany.

    Science.gov (United States)

    Berry, Maresi; Berry-Stölzle, Thomas; Schleppers, Alexander

    2008-09-01

    We examine operating room productivity on the example of hospitals in Germany with independent anesthesiology departments. Linked to anesthesiology group literature, we use the ln(Total Surgical Time/Total Anesthesiologists Salary) as a proxy for operating room productivity. We test the association between operating room productivity and different structural, organizational and management characteristics based on survey data from 87 hospitals. Our empirical analysis links improved operating room productivity to greater operating room capacity, appropriate scheduling behavior and management methods to realign interests. From this analysis, the enforcing jurisdiction and avoiding advance over-scheduling appear to be the implementable tools for improving operating room productivity.

  12. The Influence of Visual Cues on Sound Externalization

    DEFF Research Database (Denmark)

    Carvajal, Juan Camilo Gil; Santurette, Sébastien; Cubick, Jens

    while listeners wore both earplugs and blindfolds. Half of the listeners were then blindfolded during testing but were provided auditory awareness of the room via a controlled noise source (condition A). The other half could see the room but were shielded from room-related acoustic input and tested......Background: The externalization of virtual sounds reproduced via binaural headphone-based auralization systems has been reported to be less robust when the listening environment differs from the room in which binaural room impulse responses (BRIRs) were recorded. It has been debated whether.......Methods: Eighteen naïve listeners rated the externalization of virtual stimuli in terms of perceived distance, azimuthal localization, and compactness in three rooms: 1) a standard IEC listening room, 2) a small reverberant room, and 3) a large dry room. Before testing, individual BRIRs were recorded in room 1...

  13. Computational simulation in architectural and environmental acoustics methods and applications of wave-based computation

    CERN Document Server

    Sakamoto, Shinichi; Otsuru, Toru

    2014-01-01

    This book reviews a variety of methods for wave-based acoustic simulation and recent applications to architectural and environmental acoustic problems. Following an introduction providing an overview of computational simulation of sound environment, the book is in two parts: four chapters on methods and four chapters on applications. The first part explains the fundamentals and advanced techniques for three popular methods, namely, the finite-difference time-domain method, the finite element method, and the boundary element method, as well as alternative time-domain methods. The second part demonstrates various applications to room acoustics simulation, noise propagation simulation, acoustic property simulation for building components, and auralization. This book is a valuable reference that covers the state of the art in computational simulation for architectural and environmental acoustics.  

  14. Sound field control for a low-frequency test facility

    DEFF Research Database (Denmark)

    Pedersen, Christian Sejer; Møller, Henrik

    2013-01-01

    The two largest problems in controlling the reproduction of low-frequency sound for psychoacoustic experiments is the effect of the room due to standing waves and the relatively large sound pressure levels needed. Anechoic rooms are limited downward in frequency and distortion may be a problem even...... at moderate levels, while pressure-field playback can give higher sound pressures but is limited upwards in frequency. A new solution that addresses both problems has been implemented in the laboratory of Acoustics, Aalborg University. The solution uses one wall with 20 loudspeakers to generate a plane wave...... that is actively absorbed when it reaches the 20 loudspeakers on the opposing wall. This gives a homogeneous sound field in the majority of the room with a flat frequency response in the frequency range 2-300 Hz. The lowest frequencies are limited to sound pressure levels in the order of 95 dB. If larger levels...

  15. Supra-aural gossypiboma: case report of a retained textile surgical sponge in an unusual location.

    Science.gov (United States)

    Chawla, N; Gupta, N; Dhawan, N

    2016-11-01

    Gossypiboma or retained surgical sponge is an infrequently encountered surgical complication, more so in the head and neck region. A literature search did not reveal a previously reported case of retained or concealed surgical sponge after microscopic ear surgery. We present a unique and previously unreported case of a 25-year-old male who presented with a cystic swelling in the right supra-aural region 5 months post-modified radical mastoidectomy of the right ear. Surgical excision of the swelling revealed a retained surgical sponge. We emphasise the importance of counting surgical sponges after every surgical step to minimise the incidence of such retained surgical items.

  16. Evaluation of moving-coil loudspeaker and passive radiator parameters using normal-incidence sound transmission measurements: theoretical developments.

    Science.gov (United States)

    Leishman, Timothy W; Anderson, Brian E

    2013-07-01

    The parameters of moving-coil loudspeaker drivers are typically determined using direct electrical excitation and measurement. However, as electro-mechano-acoustical devices, their parameters should also follow from suitable mechanical or acoustical evaluations. This paper presents the theory of an acoustical method of excitation and measurement using normal-incidence sound transmission through a baffled driver as a plane-wave tube partition. Analogous circuits enable key parameters to be extracted from measurement results in terms of open and closed-circuit driver conditions. Associated tools are presented that facilitate adjacent field decompositions and derivations of sound transmission coefficients (in terms of driver parameters) directly from the circuits. The paper also clarifies the impact of nonanechoic receiving tube terminations and the specific benefits of downstream field decompositions.

  17. Characterizing opto-electret based paper speakers by using a real-time projection Moiré metrology system

    Science.gov (United States)

    Chang, Ya-Ling; Hsu, Kuan-Yu; Lee, Chih-Kung

    2016-03-01

    Advancement of distributed piezo-electret sensors and actuators facilitates various smart systems development, which include paper speakers, opto-piezo/electret bio-chips, etc. The array-based loudspeaker system possess several advantages over conventional coil speakers, such as light-weightness, flexibility, low power consumption, directivity, etc. With the understanding that the performance of the large-area piezo-electret loudspeakers or even the microfluidic biochip transport behavior could be tailored by changing their dynamic behaviors, a full-field real-time high-resolution non-contact metrology system was developed. In this paper, influence of the resonance modes and the transient vibrations of an arraybased loudspeaker system on the acoustic effect were measured by using a real-time projection moiré metrology system and microphones. To make the paper speaker even more versatile, we combine the photosensitive material TiOPc into the original electret loudspeaker. The vibration of this newly developed opto-electret loudspeaker could be manipulated by illuminating different light-intensity patterns. Trying to facilitate the tailoring process of the opto-electret loudspeaker, projection moiré was adopted to measure its vibration. By recording the projected fringes which are modulated by the contours of the testing sample, the phase unwrapping algorithm can give us a continuous phase distribution which is proportional to the object height variations. With the aid of the projection moiré metrology system, the vibrations associated with each distinctive light pattern could be characterized. Therefore, we expect that the overall acoustic performance could be improved by finding the suitable illuminating patterns. In this manuscript, the system performance of the projection moiré and the optoelectret paper speakers were cross-examined and verified by the experimental results obtained.

  18. Reliability of estimating the room volume from a single room impulse response

    OpenAIRE

    Kuster, M.

    2008-01-01

    The methods investigated for the room volume estimation are based on geometrical acoustics, eigenmode, and diffuse field models and no data other than the room impulse response are available. The measurements include several receiver positions in a total of 12 rooms of vastly different sizes and acoustic characteristics. The limitations in identifying the pivotal specular reflections of the geometrical acoustics model in measured room impulse responses are examined both theoretically and expe...

  19. Our Urban Living Room

    DEFF Research Database (Denmark)

    Hjortshøj, Rasmus

    2016-01-01

    Our Urban Living Room is an exhibition and a book, created by Cobe. The theme is based on Cobe’s ten years of practice, grounded in social livability and urban democracy, and our aim to create buildings and spaces that invite Copenhageners to use and define them; as an extended living room, where...... the boundaries between private and public space become fluid. Based on specific Cobe projects, Our Urban Living Room tells stories about the architectural development of Copenhagen, while exploring the progression of the Danish Capital - from an industrial city into an urban living room, known as one...... of the world’s most livable places. Photography by Rasmus Hjortshøj....

  20. Improving operating room safety

    Directory of Open Access Journals (Sweden)

    Garrett Jill

    2009-11-01

    Full Text Available Abstract Despite the introduction of the Universal Protocol, patient safety in surgery remains a daily challenge in the operating room. This present study describes one community health system's efforts to improve operating room safety through human factors training and ultimately the development of a surgical checklist. Using a combination of formal training, local studies documenting operating room safety issues and peer to peer mentoring we were able to substantially change the culture of our operating room. Our efforts have prepared us for successfully implementing a standardized checklist to improve operating room safety throughout our entire system. Based on these findings we recommend a multimodal approach to improving operating room safety.

  1. Effects of Point Count Duration, Time-of-Day, and Aural Stimuli on Detectability of Migratory and Resident Bird Species in Quintana Roo, Mexico

    Science.gov (United States)

    James F. Lynch

    1995-01-01

    Effects of count duration, time-of-day, and aural stimuli were studied in a series of unlimited-radius point counts conducted during winter in Quintana Roo, Mexico. The rate at which new species were detected was approximately three times higher during the first 5 minutes of each 15- minute count than in the final 5 minutes. The number of individuals and species...

  2. Analysis on nuclear power plant control room system design and improvement based on human factor engineering

    International Nuclear Information System (INIS)

    Gao Feng; Liu Yanzi; Sun Yongbin

    2014-01-01

    The design of nuclear power plant control room system is a process of improvement with the implementation of human factor engineering theory and guidance. The method of implementation human factor engineering principles into the nuclear power plant control room system design and improvement was discussed in this paper. It is recommended that comprehensive address should be done from control room system function, human machine interface, digital procedure, control room layout and environment design based on the human factor engineering theory and experience. The main issues which should be paid more attention during the control room system design and improvement also were addressed in this paper, and then advices and notices for the design and improvement of the nuclear power plant control room system were afforded. (authors)

  3. Room Temperature Stable PspA-Based Nanovaccine Induces Protective Immunity

    Directory of Open Access Journals (Sweden)

    Danielle A. Wagner-Muñiz

    2018-03-01

    Full Text Available Streptococcus pneumoniae is a major causative agent of pneumonia, a debilitating disease particularly in young and elderly populations, and is the leading worldwide cause of death in children under the age of five. While there are existing vaccines against S. pneumoniae, none are protective across all serotypes. Pneumococcal surface protein A (PspA, a key virulence factor of S. pneumoniae, is an antigen that may be incorporated into future vaccines to address the immunological challenges presented by the diversity of capsular antigens. PspA has been shown to be immunogenic and capable of initiating a humoral immune response that is reactive across approximately 94% of pneumococcal strains. Biodegradable polyanhydrides have been studied as a nanoparticle-based vaccine (i.e., nanovaccine platform to stabilize labile proteins, to provide adjuvanticity, and enhance patient compliance by providing protective immunity in a single dose. In this study, we designed a room temperature stable PspA-based polyanhydride nanovaccine that eliminated the need for a free protein component (i.e., 100% encapsulated within the nanoparticles. Mice were immunized once with the lead nanovaccine and upon challenge, presented significantly higher survival rates than animals immunized with soluble protein alone, even with a 25-fold reduction in protein dose. This lead nanovaccine formulation performed similarly to protein adjuvanted with Alum, however, with much less tissue reactogenicity at the site of immunization. By eliminating the free PspA from the nanovaccine formulation, the lead nanovaccine was efficacious after being stored dry for 60 days at room temperature, breaking the need for maintaining the cold chain. Altogether, this study demonstrated that a single dose PspA-based nanovaccine against S. pneumoniae induced protective immunity and provided thermal stability when stored at room temperature for at least 60 days.

  4. Auralization of Accelerating Passenger Cars Using Spectral Modeling Synthesis

    Directory of Open Access Journals (Sweden)

    Reto Pieren

    2015-12-01

    Full Text Available While the technique of auralization has been in use for quite some time in architectural acoustics, the application to environmental noise has been discovered only recently. With road traffic noise being the dominant noise source in most countries, particular interest lies in the synthesis of realistic pass-by sounds. This article describes an auralizator for pass-bys of accelerating passenger cars. The key element is a synthesizer that simulates the acoustical emission of different vehicles, driving on different surfaces, under different operating conditions. Audio signals for the emitted tire noise, as well as the propulsion noise are generated using spectral modeling synthesis, which gives complete control of the signal characteristics. The sound of propulsion is synthesized as a function of instantaneous engine speed, engine load and emission angle, whereas the sound of tires is created in dependence of vehicle speed and emission angle. The sound propagation is simulated by applying a series of time-variant digital filters. To obtain the corresponding steering parameters of the synthesizer, controlled experiments were carried out. The tire noise parameters were determined from coast-by measurements of passenger cars with idling engines. To obtain the propulsion noise parameters, measurements at different engine speeds, engine loads and emission angles were performed using a chassis dynamometer. The article shows how, from the measured data, the synthesizer parameters are calculated using audio signal processing.

  5. An Overview of Auralization and Psychoacoustics

    Science.gov (United States)

    Begault, Durand R.; Null, Cynthia H. (Technical Monitor)

    1998-01-01

    This viewgraph presentation provides information on a study the goal of which was to determine the auditory threshold for speech reverberation using a specific room model. Procedures and hardware used are detailed as are the participants in the study.

  6. Creating Engaging Escape Rooms for the Classroom

    Science.gov (United States)

    Nicholson, Scott

    2018-01-01

    Escape rooms are "live-action team-based games where players discover clues, solve puzzles, and accomplish tasks in one or more rooms in order to accomplish a specific goal (usually escaping from the room) in a limited amount of time." Escape Rooms are one type of Escape Game, which are narrative-based challenges that use puzzles, tasks,…

  7. Improving operating room turnover time: a systems based approach.

    Science.gov (United States)

    Bhatt, Ankeet S; Carlson, Grant W; Deckers, Peter J

    2014-12-01

    Operating room (OR) turnover time (TT) has a broad and significant impact on hospital administrators, providers, staff and patients. Our objective was to identify current problems in TT management and implement a consistent, reproducible process to reduce average TT and process variability. Initial observations of TT were made to document the existing process at a 511 bed, 24 OR, academic medical center. Three control groups, including one consisting of Orthopedic and Vascular Surgery, were used to limit potential confounders such as case acuity/duration and equipment needs. A redesigned process based on observed issues, focusing on a horizontally structured, systems-based approach has three major interventions: developing consistent criteria for OR readiness, utilizing parallel processing for patient and room readiness, and enhancing perioperative communication. Process redesign was implemented in Orthopedics and Vascular Surgery. Comparisons of mean and standard deviation of TT were made using an independent 2-tailed t-test. Using all surgical specialties as controls (n = 237), mean TT (hh:mm:ss) was reduced by 0:20:48 min (95 % CI, 0:10:46-0:30:50), from 0:44:23 to 0:23:25, a 46.9 % reduction. Standard deviation of TT was reduced by 0:10:32 min, from 0:16:24 to 0:05:52 and frequency of TT≥30 min was reduced from 72.5to 11.7 %. P systems-based focus should drive OR TT design.

  8. Health Service Quality Based On Dabholkar Dimension At Ward Room Of Internal Disease

    OpenAIRE

    Supriyanto, Stefanus; Rahmawati, Alfi Febriana

    2013-01-01

    The NDR average at ward room of internal disease of Bojonegoro General Hospital during 2009-2011 was 58,6 ‰ (more than standard < 25 ‰). This research was aimed to analyze the importance and satisfaction rating of health service quality based on Dabholkar dimension. It used observational approach with cross sectional design. Interview was conducted to 37 patients in internal disease ward room of Bojonegoro General Hospital which selected by simple random sampling. This study found some issues...

  9. Modern control room for AHWR

    International Nuclear Information System (INIS)

    Verghese, Clement C.; Joseph, Jose; Biswas, B.B.; Patil, R.K.

    2005-01-01

    Advanced Heavy Water Reactor (AHWR) is a next generation nuclear power plant being developed by Bhabha Atomic Research Centre. A modern control room has been conceived for operation and monitoring of the plant in tune with the advanced features of the reactor. A state of the art C and I architecture based on extensive use of computers and networking has been conceived for this plant. This architecture enables the implementation of a fully computerised operator friendly control room with soft HMIs. Features of the modern control room and control room and concept of soft HMI based operator interfaces have been described in the paper. (author)

  10. Room temperature ferromagnetism in a phthalocyanine based carbon material

    International Nuclear Information System (INIS)

    Honda, Z.; Sato, K.; Sakai, M.; Fukuda, T.; Kamata, N.; Hagiwara, M.; Kida, T.

    2014-01-01

    We report on a simple method to fabricate a magnetic carbon material that contains nitrogen-coordinated transition metals and has a large magnetic moment. Highly chlorinated iron phthalocyanine was used as building blocks and potassium as a coupling reagent to uniformly disperse nitrogen-coordinated iron atoms on the phthalocyanine based carbon material. The iron phthalocyanine based carbon material exhibits ferromagnetic properties at room temperature and the ferromagnetic phase transition occurs at T c  = 490 ± 10 K. Transmission electron microscopy observation, X-ray diffraction analysis, and the temperature dependence of magnetization suggest that the phthalocyanine molecules form three-dimensional random networks in the iron phthalocyanine based carbon material

  11. Room temperature ferromagnetism in a phthalocyanine based carbon material

    Energy Technology Data Exchange (ETDEWEB)

    Honda, Z., E-mail: honda@fms.saitama-u.ac.jp; Sato, K.; Sakai, M.; Fukuda, T.; Kamata, N. [Graduate School of Science and Engineering, Saitama University, 255 Shimo-Okubo, Sakura-ku, Saitama 338-8570 (Japan); Hagiwara, M.; Kida, T. [KYOKUGEN (Center for Quantum Science and Technology under Extreme Conditions), Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan)

    2014-02-07

    We report on a simple method to fabricate a magnetic carbon material that contains nitrogen-coordinated transition metals and has a large magnetic moment. Highly chlorinated iron phthalocyanine was used as building blocks and potassium as a coupling reagent to uniformly disperse nitrogen-coordinated iron atoms on the phthalocyanine based carbon material. The iron phthalocyanine based carbon material exhibits ferromagnetic properties at room temperature and the ferromagnetic phase transition occurs at T{sub c} = 490 ± 10 K. Transmission electron microscopy observation, X-ray diffraction analysis, and the temperature dependence of magnetization suggest that the phthalocyanine molecules form three-dimensional random networks in the iron phthalocyanine based carbon material.

  12. Auralization of vibroacoustic models in engineering using Wave Field Synthesis: Application to plates and transmission loss

    Science.gov (United States)

    Bolduc, A.; Gauthier, P.-A.; Berry, A.

    2017-12-01

    While perceptual evaluation and sound quality testing with jury are now recognized as essential parts of acoustical product development, they are rarely implemented with spatial sound field reproduction. Instead, monophonic, stereophonic or binaural presentations are used. This paper investigates the workability and interest of a method to use complete vibroacoustic engineering models for auralization based on 2.5D Wave Field Synthesis (WFS). This method is proposed in order that spatial characteristics such as directivity patterns and direction-of-arrival are part of the reproduced sound field while preserving the model complete formulation that coherently combines frequency and spatial responses. Modifications to the standard 2.5D WFS operators are proposed for extended primary sources, affecting the reference line definition and compensating for out-of-plane elementary primary sources. Reported simulations and experiments of reproductions of two physically-accurate vibroacoustic models of thin plates show that the proposed method allows for an effective reproduction in the horizontal plane: Spatial and frequency domains features are recreated. Application of the method to the sound rendering of a virtual transmission loss measurement setup shows the potential of the method for use in virtual acoustical prototyping for jury testing.

  13. TUGAS ROOM ATTENDANT DALAM MENANGANI COMPLAINT TAMU DELUXE ROOM HOTEL HYAAT REGENCY BANDUNG

    Directory of Open Access Journals (Sweden)

    Reza Gustia Purnama

    2016-05-01

    Full Text Available Abstract - The problem is how meticulous the duties and responsibilities of the room attendant in the deluxe room Hotel Hyatt Regency Bandung, standard operational procedures in the deluxe room Hotel Hyatt Regency Bandung, and handling guest complaint in deluxe room Hotel Hyatt Regency Bandung. Author uses descriptive analysis, which is a form of writing in the actual situation describes strive about the object of research, then the data obtained in the form of a report compiled in. Based on the results of observation it can be concluded that the task and responsibility of the room attendant in the deluxe room Hyatt Regency Bandung already carry it out in accordance with standard operational procedures (SOP which is divided into two shifts, morning and evening shift which has a slightly different task, standard operational procedures in the deluxe room Hyatt Regency Bandung has been standard operating procedure in applying it at the hotel Hyatt Regency Bandung, and Guest complaint handling in deluxe room Hyatt Regency Bandung Hotel how to deal with and resolve the complaint vary slightly in view of the type of complaint. Based on the results of observation and discussion, the authors conclude that the Duty room attendant in handling customers compaint deluxe room in the Hyatt Regency Bandung Hotel when his handlers was conducted appropriately and propesional effects will be good for the image of the hyatt regency hotel bandung.   Keywords: Room Attendant, Complaint, Deluxe room   Abstraksi - Masalah yang di teliti adalah tugas dan tanggung jawab room attendant di deluxe room Hotel Hyatt Regency Bandung, standar operasional prosedur di deluxe room Hotel Hyatt Regency Bandung, dan penanganan complaint tamu di deluxe room Hotel Hyatt Regency Bandung.  Metode yang di gunakan menggunakan analisis deskriptif, yaitu bentuk penulisan yang di upayakan menggambarkan keadaan yang sebenarnya tetang objek penelitian,kemudian data yang di peroleh disusun

  14. How does Architecture Sound for Different Musical Instrument Performances?

    DEFF Research Database (Denmark)

    Saher, Konca; Rindel, Jens Holger

    2006-01-01

    This paper discusses how consideration of sound _in particular a specific musical instrument_ impacts the design of a room. Properly designed architectural acoustics is fundamental to improve the listening experience of an instrument in rooms in a conservatory. Six discrete instruments (violin, c...... different instruments and the choir experience that could fit into same category of room. For all calculations and the auralizations, a computational model is used: ODEON 7.0....

  15. Room-temperature base-free copper-catalyzed trifluoromethylation of organotrifluoroborates to trifluoromethylarenes

    KAUST Repository

    Huang, Yuanyuan; Fang, Xin; Lin, Xiaoxi; Li, Huaifeng; He, Weiming; Huang, Kuo-Wei; Yuan, Yaofeng; Weng, Zhiqiang

    2012-01-01

    An efficient room temperature copper-catalyzed trifluoromethylation of organotrifluoroborates under the base free condition using an electrophilic trifluoromethylating reagent is demonstrated. The corresponding trifluoromethylarenes were obtained in good to excellent yields and the reaction tolerates a wide range of functional groups. © 2012 Elsevier Ltd. All rights reserved.

  16. Room-temperature base-free copper-catalyzed trifluoromethylation of organotrifluoroborates to trifluoromethylarenes

    KAUST Repository

    Huang, Yuanyuan

    2012-12-01

    An efficient room temperature copper-catalyzed trifluoromethylation of organotrifluoroborates under the base free condition using an electrophilic trifluoromethylating reagent is demonstrated. The corresponding trifluoromethylarenes were obtained in good to excellent yields and the reaction tolerates a wide range of functional groups. © 2012 Elsevier Ltd. All rights reserved.

  17. Annoyance of low frequency noise and traffic noise

    DEFF Research Database (Denmark)

    Mortensen, F.R.; Poulsen, Torben

    2001-01-01

    The annoyance of different low frequency noise sources was determined and compared to the annoyance from traffic noise. Twenty-two subjects participated in laboratory listening tests. The sounds were presented by loudspeakers in a listening room and the spectra of the low frequency noises were...

  18. Alcohol based surgical prep solution and the risk of fire in the operating room: a case report

    Directory of Open Access Journals (Sweden)

    Gupta Rajiv

    2008-04-01

    Full Text Available Abstract A few cases of fire in the operating room are reported in the literature. The factors that may initiate these fires are many and include alcohol based surgical prep solutions, electrosurgical equipment, flammable drapes etc. We are reporting a case of fire in the operating room while operating on a patient with burst fracture C6 vertebra with quadriplegia. The cause of the fire was due to incomplete drying of the covering drapes with an alcohol based surgical prep solution. This paper discusses potential preventive measures to minimize the incidence of fire in the operating room.

  19. Control room design and human factors using a virtual reality based tool for design, test and training

    International Nuclear Information System (INIS)

    Lirvall, Peter

    1998-02-01

    This report describes a user-centred approach to control room design adopted by IFE for the nuclear industry. The novelty of this approach is the development of a Control Room Philosophy, and the use of Virtual Reality (VR) technology as a tool in the design process, integrated with a specially developed Design Documentation System (DDS) and a process display prototyping tool PICASSO-3. The control room philosophy identifies all functional aspects of a control centre, to define the baseline principles and guidelines for the design. The use of VR technology enables end-users of the control room design (e.g. control room operators) to specify their preferred design of the new control room, and to replace the need for a physical mock-up to test and evaluate the proposed design. The DDS, integrated with the VR design tool, guides the control room operators, through a structured approach, to document the proposed design in a complete design specification. The VR tool, specially developed by IFE, is called the VR based Design, Test and Training tool (VR DTandT). It is not only intended to visualise the design, but also to test and evaluate the design. When the design is implemented, the same model is re-used as a VR based training simulator for operators. A special feature in the VR DTandT tool is that the verification and validation (VandV) tests, concerning human factors, are according to the regulative standards for nuclear control rooms

  20. Check-list for the assessment of functional impairment in children with congenital aural atresia.

    Science.gov (United States)

    Montino, Silvia; Agostinelli, Anna; Trevisi, Patrizia; Martini, Alessandro; Ghiselli, Sara

    2017-11-01

    Congenital Aural Atresia (CAA) is a deformity of the external ear and it is commonly associated with malformations of middle and inner ear and, in some cases, with other facial deformities. Very few assessment measures exist for evaluating the functional impairment in children with CAA. Purpose of this study is to introduce and describe an assessment Checklist, (nominated FOS Checklist) that covers feeding abilities (F), oralmotor skills (O), communication/language development (S) in children with CAA. FOS wants to offer a range of assessment providing a profile of the child in comparison to hearing peers and it aims to make clinicians able to identify additional problems and areas of difficulties as well as specific abilities and skills. Secondary, we want to investigate the presence of correlations between disorders and side of CAA. a new Checklist (FOS Checklist) was administered to 68 children with CAA. Feeding abilities are age-adequate in 94,3% of all patients. 54,4% of all patients are in need for further assessment of their oral-motor skills; delays in language development were found in 44,1% of cases. Orofacial development delays have been observed in 57.2% of subjects among the bilateral CAA group, in 53.9% among the right CAA group and in 53.4% among the left CAA group. Patients referred for further language evaluation were 42,9% in the bilateral CAA group, 33.3% in the right CAA group and 33.3% in the left CAA group. According to the χ 2 analysis, referral for further assessment is independent from side of aural atresia. Subjects with bilateral CAA are more likely to be referred for further assessment, both for oral motor aspects and for speech perception and language development. However, there is not a significant statistical difference between the performances of children with bilateral or unilateral CAA. FOS Checklist is simple, reliable and time effective and can be used in everyday clinical practice. FOS enable clinicians to identify additional

  1. Design and Evaluation of Accelerometer based Motional Feedback

    DEFF Research Database (Denmark)

    Schneider, Henrik; Pranjic, Emilio; Agerkvist, Finn T.

    2015-01-01

    and enable radical design changes in the loudspeaker which can lead to efficiency improvements. In combination this has motivated a revisit of the accelerometer based motional feedback technique. Experimental results on a 8 inch subwoofer show that the total harmonic distortion can be significantly reduced...

  2. Human-machine interface aspects and use of computer-based operator support systems in control room upgrades and new control room designs for nuclear power plants

    International Nuclear Information System (INIS)

    Berg, O.

    1997-01-01

    At the Halden Project efforts are made to explore the possibilities through design, development and validation of Computer-based Operator Support Systems (COSSes) which can assist the operators in different operational situations, ranging from normal operation to disturbance and accident conditions. The programme comprises four main activities: 1) verification and validation of safety critical software systems; 2) man-machine interaction research emphasizing improvements in man-machine interfaces on the basis of human factors studies; 3) computerized operator support systems assisting the operator in fault detection/diagnosis and planning of control actions; and 4) control room development providing a basis for retrofitting of existing control rooms and for the design of advanced concepts. The paper presents the status of this development programme, including descriptions of specific operator support functions implemented in the simulator-based, experimental control room at Halden (HAMMLAB, HAlden Man-Machine LABoratory). These operator aids comprise advanced alarms systems, diagnostic support functions, electronic procedures, critical safety functions surveillance and accident management support systems. The different operator support systems development at the Halden Project are tested and evaluated in HAMMLAB with operators from the Halden Reactor, and occasionally from commercial NPPs, as test subjects. These evaluations provide data on the merits of different operator support systems in an advanced control room setting, as well as on how such systems should be integrated to enhance operator performance. The paper discusses these aspects and the role of computerized operator support systems in plant operation based on the experience from this work at the Halden Project. 15 refs, 5 figs

  3. Human-machine interface aspects and use of computer-based operator support systems in control room upgrades and new control room designs for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Berg, O [Institutt for Energiteknikk, OECD Halden Reactor Project (Netherlands)

    1997-07-01

    At the Halden Project efforts are made to explore the possibilities through design, development and validation of Computer-based Operator Support Systems (COSSes) which can assist the operators in different operational situations, ranging from normal operation to disturbance and accident conditions. The programme comprises four main activities: 1) verification and validation of safety critical software systems; 2) man-machine interaction research emphasizing improvements in man-machine interfaces on the basis of human factors studies; 3) computerized operator support systems assisting the operator in fault detection/diagnosis and planning of control actions; and 4) control room development providing a basis for retrofitting of existing control rooms and for the design of advanced concepts. The paper presents the status of this development programme, including descriptions of specific operator support functions implemented in the simulator-based, experimental control room at Halden (HAMMLAB, HAlden Man-Machine LABoratory). These operator aids comprise advanced alarms systems, diagnostic support functions, electronic procedures, critical safety functions surveillance and accident management support systems. The different operator support systems development at the Halden Project are tested and evaluated in HAMMLAB with operators from the Halden Reactor, and occasionally from commercial NPPs, as test subjects. These evaluations provide data on the merits of different operator support systems in an advanced control room setting, as well as on how such systems should be integrated to enhance operator performance. The paper discusses these aspects and the role of computerized operator support systems in plant operation based on the experience from this work at the Halden Project. 15 refs, 5 figs.

  4. Persuasive technology based on bodily comfort experiences : the effect of color temperature of room lighting on user motivation to change room temperature

    NARCIS (Netherlands)

    Lu, S.; Ham, J.R.C.; Midden, C.J.H.; MacTavish, T.; Basapur, S.

    2015-01-01

    In this paper we propose a new perspective on persuasive technology: Comfort-Experience-Based Persuasive Technology. We argue that comfort experiences have a dominant influence on people’s (energy consumption) behavior. In the current research, we argue that room lighting can influence

  5. TaS2 nanosheet-based room-temperature dosage meter for nitric oxide

    Directory of Open Access Journals (Sweden)

    Qiyuan He

    2014-09-01

    Full Text Available A miniature dosage meter for toxic gas is developed based on TaS2 nanosheets, which is capable of indicating the toxic dosage of trace level NO at room temperature. The TaS2 film-based chemiresistor shows an irreversible current response against the exposure of NO. The unique non-recovery characteristic makes the TaS2 film-based device an ideal indicator of total dosage of chronicle exposure.

  6. Room Volume Estimation Based on Ambiguity of Short-Term Interaural Phase Differences Using Humanoid Robot Head

    Directory of Open Access Journals (Sweden)

    Ryuichi Shimoyama

    2016-07-01

    Full Text Available Humans can recognize approximate room size using only binaural audition. However, sound reverberation is not negligible in most environments. The reverberation causes temporal fluctuations in the short-term interaural phase differences (IPDs of sound pressure. This study proposes a novel method for a binaural humanoid robot head to estimate room volume. The method is based on the statistical properties of the short-term IPDs of sound pressure. The humanoid robot turns its head toward a sound source, recognizes the sound source, and then estimates the ego-centric distance by its stereovision. By interpolating the relations between room volume, average standard deviation, and ego-centric distance experimentally obtained for various rooms in a prepared database, the room volume was estimated by the binaural audition of the robot from the average standard deviation of the short-term IPDs at the estimated distance.

  7. A room-temperature non-volatile CNT-based molecular memory cell

    Science.gov (United States)

    Ye, Senbin; Jing, Qingshen; Han, Ray P. S.

    2013-04-01

    Recent experiments with a carbon nanotube (CNT) system confirmed that the innertube can oscillate back-and-forth even under a room-temperature excitation. This demonstration of relative motion suggests that it is now feasible to build a CNT-based molecular memory cell (MC), and the key to bring the concept to reality is the precision control of the moving tube for sustained and reliable read/write (RW) operations. Here, we show that by using a 2-section outertube design, we are able to suitably recalibrate the system energetics and obtain the designed performance characteristics of a MC. Further, the resulting energy modification enables the MC to operate as a non-volatile memory element at room temperatures. Our paper explores a fundamental understanding of a MC and its response at the molecular level to roadmap a novel approach in memory technologies that can be harnessed to overcome the miniaturization limit and memory volatility in memory technologies.

  8. The effect of foreign accent on employability : a study of the aural dimensions of aesthetic labour in customer-facing and non-customer-facing jobs

    OpenAIRE

    Timming, Andrew R.

    2016-01-01

    Using quantitative methods, this article examines the effect of foreign accents on job applicants’ employability ratings in the context of a simulated employment interview experiment conducted in the USA. It builds upon the literature on aesthetic labour, which focuses largely on the role of physical appearance in employment relations, by shifting attention to its under-investigated auditory and aural dimensions. The results suggest that the managerial respondents actively discriminate in tel...

  9. Hybrid control rooms: the effects of introducing new technology into existing control rooms

    International Nuclear Information System (INIS)

    Morisseau, Dolores S.

    2001-02-01

    The goal of this part of the Hybrid Control Room Project is to gain a perspective on the issues and problems that are an integral part of introducing new technology, automated systems, or support systems into nuclear power plant (NPP) control rooms, particularly when they are introduced on a system-by-system basis. For purposes of this project, hybrid control rooms are defined as those into which new technology, such as digital and computer-based controls are gradually incorporated as opposed to those that are completely, or nearly completely, refitted with new technology. Although the focus of this project is the introduction of computer based, digital systems into NPP control rooms, it is not possible to exclude the effects throughout the process that are inevitable when new technology is introduced anywhere in complex process control systems. Thus, this document examines the effects of such changes within the context of the organisation in which they occur, including the management of change, work procedures and work methods, communications and crew interaction, training, and the interdependent functions in the operational context. (Author)

  10. A hybrid algorithm for selecting head-related transfer function based on similarity of anthropometric structures

    Science.gov (United States)

    Zeng, Xiang-Yang; Wang, Shu-Guang; Gao, Li-Ping

    2010-09-01

    As the basic data for virtual auditory technology, head-related transfer function (HRTF) has many applications in the areas of room acoustic modeling, spatial hearing and multimedia. How to individualize HRTF fast and effectively has become an opening problem at present. Based on the similarity and relativity of anthropometric structures, a hybrid HRTF customization algorithm, which has combined the method of principal component analysis (PCA), multiple linear regression (MLR) and database matching (DM), has been presented in this paper. The HRTFs selected by both the best match and the worst match have been applied into obtaining binaurally auralized sounds, which are then used for subjective listening experiments and the results are compared. For the area in the horizontal plane, the localization results have shown that the selection of HRTFs can enhance the localization accuracy and can also abate the problem of front-back confusion.

  11. Apresentação do processo de confecção da cápsula do aparelho de amplificação sonora individual intra-aural por meio de digitalização Presenting the process of making the capsule of intra-aural hearing aid through digitization

    Directory of Open Access Journals (Sweden)

    Jerusa Roberta Massola de Oliveira

    2013-02-01

    Full Text Available OBJETIVO: o objetivo deste estudo é apresentar as etapas do processo de confecção da cápsula do aparelho de amplificação sonora individual intra-aural por meio da digitalização. MÉTODO: foram utilizadas otoplásticas e os equipamentos Legato para realizar o escaneamento e Envisiontec para sinterização, ambos disponibilizados pela empresa Phonak. RESULTADOS: os resultados sinalizam para cápsula de aparelho de amplificação sonora individual intra-aurais, plenamente satisfatórias, sendo constatada todas as vantagens documentadas pelo fabricante. CONCLUSÃO: a nova técnica de confecção de cápsula por meio de processo de digitalização demonstrou ser eficaz com alta qualidade e mantendo a impressão fiel da orelha, além de durabilidade significativa.PURPOSE: the objective of this study is to present the steps involved in making the capsule of intra-aural hearing aids through scanning. METHOD: we used the Legato otoplasty equipment in order to perform scanning and Enisiontec for sintering, both provided by the company Phonak. RESULTS: the results point out to capsule-ear hearing aid, as being fully satisfying and with all the benefits documented by the manufacturer. CONCLUSION: a new technique in order to make the capsule through the scanning process has been proven effective and with high quality and keeping the faithful imprint of the ear, in addition to significant durability.

  12. Evaluating the short-term and long-term effects of an internet-based aural rehabilitation programme for hearing aid users in general clinical practice: a randomised controlled trial.

    Science.gov (United States)

    Malmberg, Milijana; Lunner, Thomas; Kähäri, Kim; Andersson, Gerhard

    2017-06-06

    Guided internet-based intervention beyond hearing aid (HA) fitting has been shown to be efficacious in randomised controlled trials (RCTs). However, internet interventions have rarely been applied clinically as a part of regular aural rehabilitation (AR). Our aim was to evaluate the effectiveness of internet-based AR for HA users from a clinical population. The Hearing Handicap Inventory for the Elderly (HHIE) was used as the primary outcome measure, and the Communication Strategies Scale (CSS) and the Hospital Anxiety and Depression Scale were used as secondary outcome measures. All questionnaires were administered before and directly after the intervention and at 6 months postintervention. We used a parallel group design (RCT). The data were collected in 2013-2014 at three different clinics. Seventy-four HA users were randomly assigned to receive either full internet-based AR (intervention group, n=37) or one element of the internet-based AR (control group, n=37). Data were analysed following the intention-to-treat principle. Each group showed improved HHIE scores over time and did not differ significantly from each other. The intervention group showed significantly greater improvement compared with the control group for the CSS total and the non-verbal subscale scores. The intervention group and control group were also subdivided into two age groups: 20-59 years and 60-80 years. Significantly better improvement on the CSS total and non-verbal subscale scores was found in the older group compared with the younger participants. This study indicates that participants in an internet-based intervention applied in general clinical practice showed improved self-reported communication skills compared with a control group. Receiving a full intervention was not more effective in improving self-reported hearing problems than receiving just one element of the internet-based intervention. This trial is registered at ClinicalTrals.gov, NCT01837550; results. © Article author

  13. Odeon, a design tool for auditorium acoustics, noise control and loudspeaker systems

    DEFF Research Database (Denmark)

    Christensen, Claus Lynge

    2001-01-01

    The ODEON software was originally developed for prediction of auditorium acoustics. However current editions of the software are not limited to these fields, but also allow prediction in rooms such as churches and mosques, interior noise control, design of room acoustics and sound distribution...

  14. Using an integrative mock-up simulation approach for evidence-based evaluation of operating room design prototypes.

    Science.gov (United States)

    Bayramzadeh, Sara; Joseph, Anjali; Allison, David; Shultz, Jonas; Abernathy, James

    2018-07-01

    This paper describes the process and tools developed as part of a multidisciplinary collaborative simulation-based approach for iterative design and evaluation of operating room (OR) prototypes. Full-scale physical mock-ups of healthcare spaces offer an opportunity to actively communicate with and to engage multidisciplinary stakeholders in the design process. While mock-ups are increasingly being used in healthcare facility design projects, they are rarely evaluated in a manner to support active user feedback and engagement. Researchers and architecture students worked closely with clinicians and architects to develop OR design prototypes and engaged clinical end-users in simulated scenarios. An evaluation toolkit was developed to compare design prototypes. The mock-up evaluation helped the team make key decisions about room size, location of OR table, intra-room zoning, and doors location. Structured simulation based mock-up evaluations conducted in the design process can help stakeholders visualize their future workspace and provide active feedback. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. THE APPLICATION OF EVIDENCE BASED DESIGN IN EMERGENCY ROOM OF PUBLIC HOSPITAL OF DR. R. SOSODORO DJATIKOESOEMO BOJONEGORO

    Directory of Open Access Journals (Sweden)

    Noerkayatin ,

    2015-07-01

    Full Text Available The Hospital facilities built under Evidence Based Design (EBD will create a safe and comfortable environment, lower the nosocomial infection, quicken the patient recovery, lower the treatment cost, and improve staffs’ performance. The emergency room of public hospital of Dr.R.Sosodoro Djatikoesoemo Bojonegoro needs to be redesigned because the existing design does not meet physical safety. The reparation should refer to Facilities and Safety Management (FMS, Indonesian regulation, EBD concept and benchmarking to RSCM Jakarta considered as an application sample. This research applies case study with descriptive single case study design. The result of the research shows that reparation should be done that includes site and location, building components, and rooms lay out. The width of the rooms should meet minimal standard. The placing of triage room and resuscitation should be in the front area. Sinks should be located near the entrance of every room. The isolation and decontamination rooms should be provided.

  16. Calculation of Appropriate Minimum Size of Isolation Rooms based on Questionnaire Survey of Experts and Analysis on Conditions of Isolation Room Use

    Science.gov (United States)

    Won, An-Na; Song, Hae-Eun; Yang, Young-Kwon; Park, Jin-Chul; Hwang, Jung-Ha

    2017-07-01

    After the outbreak of the MERS (Middle East Respiratory Syndrome) epidemic, issues were raised regarding response capabilities of medical institutions, including the lack of isolation rooms at hospitals. Since then, the government of Korea has been revising regulations to enforce medical laws in order to expand the operation of isolation rooms and to strengthen standards regarding their mandatory installation at hospitals. Among general and tertiary hospitals in Korea, a total of 159 are estimated to be required to install isolation rooms to meet minimum standards. For the purpose of contributing to hospital construction plans in the future, this study conducted a questionnaire survey of experts and analysed the environment and devices necessary in isolation rooms, to determine their appropriate minimum size to treat patients. The result of the analysis is as follows: First, isolation rooms at hospitals are required to have a minimum 3,300mm minor axis and a minimum 5,000mm major axis for the isolation room itself, and a minimum 1,800mm minor axis for the antechamber where personal protective equipment is donned and removed. Second, the 15 ㎡-or-larger standard for the floor area of isolation rooms will have to be reviewed and standards for the minimum width of isolation rooms will have to be established.

  17. Equivalent threshold sound pressure levels (ETSPL) for Sennheiser HDA 280 supra-aural audiometric earphones in the frequency range 125 Hz to 8000 Hz

    DEFF Research Database (Denmark)

    Poulsen, Torben; Oakley, Sebastian

    2009-01-01

    Hearing threshold sound pressure levels were measured for the Sennheiser HDA 280 audiometric earphone. Hearing thresholds were measured for 25 normal hearing test subjects at the 11 audiometric test frequencies from 125 Hz to 8000 Hz. Sennheiser HDA 280 is a supra-aural earphone that may be seen...... as a substitute for the classical Telephonics TDH 39. The results are given as the Equivalent Threshold Sound Pressure Level, ETSPL, measured in an acoustic coupler specified in IEC 60318-3. The results are in good agreement with an independent investigation from PTB, Braunschweig, Germany. From acoustic...

  18. Gas explosion in a room with a window and passage to an adjacent room

    Directory of Open Access Journals (Sweden)

    Polandov Yuri

    2016-01-01

    Full Text Available Some publications describe an effect, produced during a physical model experiment, when an adjacent gas-free room influences the gas explosion pressure in a room with a window. The explosion pressure in this case significantly exceeds (2.5 times the explosion pressure in a room without an adjacent room. This result has been confirmed by our studies. Based on other available information about the influence of the ignition point location on the explosion pressure in one room, it was suggested that this could be true for an explosion in two rooms. In our studies we used a test unit with two connected chambers, each having a volume of 1.125 m3. It turned out that this influence of the adjacent volume was not so unambiguous as it was described in those publications. It was found out that the maximum effect of explosion pressure amplification by the adjacent room is achieved, when the igniter is located in the chamber filled with a gas-air mixture in the area between the center of the chamber and the window (maximum amplification by more than 3 times. This effect is lower directly by the window (1.8 times and is practically absent in case of ignition within the area near the passage connecting the chamber with the adjacent room. This suggests that the effect discovered earlier is a special case of the general dependence of the gas explosion pressure in two chambers on the igniter location.

  19. Control room philosophy: Principles of control room design and control room work

    International Nuclear Information System (INIS)

    Skriver, Jan; Ramberg, Jasmine; Allwin, Pernilla

    2006-01-01

    In order to provide insights for improvement of work in control rooms several factors have to be considered. Knowledge of principles including control room philosophies will guide the recommended improvements. In addition to knowledge about specific principles an advantage for an organization can be an understanding of similarities and policies used in other high risk industry. The report has been developed on the basis of a document analysis of international standards and other guiding documents. (NUREG 0711, ISO 11064, ISO 6385, IEC 60964). In addition to the document analysis which has strived to compare the documents to see similarities in important principals, experience from working with control room design, modifications and evaluations in other high risk industries has pervaded the report. Important principles have been identified which are recommended to be included in a control room philosophy. Many of these are similar to the principles identified in the international standards. An additional principal which is regarded as important is the utilization of Key Performance Indicators (KPI) which can be used as a measure to target preventative means. Further more it is critical that the control room philosophy is easy to access and comprehend for all users. One of the challenges that remain after having developed a control room philosophy is how to utilize it in the daily work situation. It is vital that the document remains as a living document, guiding the continual improvement of the control room in the various life cycle stages

  20. [Design and Implementation of a Mobile Operating Room Information Management System Based on Electronic Medical Record].

    Science.gov (United States)

    Liu, Baozhen; Liu, Zhiguo; Wang, Xianwen

    2015-06-01

    A mobile operating room information management system with electronic medical record (EMR) is designed to improve work efficiency and to enhance the patient information sharing. In the operating room, this system acquires the information from various medical devices through the Client/Server (C/S) pattern, and automatically generates XML-based EMR. Outside the operating room, this system provides information access service by using the Browser/Server (B/S) pattern. Software test shows that this system can correctly collect medical information from equipment and clearly display the real-time waveform. By achieving surgery records with higher quality and sharing the information among mobile medical units, this system can effectively reduce doctors' workload and promote the information construction of the field hospital.

  1. Fast rendering of scanned room geometries

    DEFF Research Database (Denmark)

    Olesen, Søren Krarup; Markovic, Milos; Hammershøi, Dorte

    2014-01-01

    Room acoustics are rendered in Virtual Realities based on models of the real world. These are typically rather coarse representations of the true geometry resulting in room impulse responses with a lack of natural detail. This problem can be overcome by using data scanned by sensors, such as e...

  2. A recovery room-based acute pain service.

    Science.gov (United States)

    Leykin, Y; Pellis, T; Ambrosio, C; Zanette, G; Malisano, A; Rapotec, A; Casati, A

    2007-04-01

    Despite routine postoperative pain management improves recovery and reduces postoperative morbidity and overall costs, and the availability of a large armamentarium of analgesic techniques and drugs, a significant portion of patients do not receive adequate postoperative pain control. We describe a recovery room (RR) based acute pain service model. Guidelines on postoperative pain and therapeutic protocols were instituted in January 1999. The analgesic endpoint was a visual analogic scale (VAS) below 4 for all surgical patients for the first 48-72 h. The RR, run by one anesthesiologist and 2 nurses and one assistant, acted as a coordination centre. Discharge from the RR was subject to achieving effective analgesia. Nurses of each ward monitored VAS along with vital signs, administered rescue doses if necessary, and reported to the RR nurse when needed. RR nurses monitored the patient at least twice daily and reported to the anesthesiologist. We have distributed an anonymous questionnaire, within surgical wards, to both surgeons and nurses to evaluate their perception of pain management and of this acute pain service (APS) model. VAS was maintained significantly process confirmed the desire of all professional figures to be informed and involved in acute pain management as part of a coordinated and systematic approach to the surgical patient. A RR-based APS can effectively act as coordinating centre for acute pain treatment without adjunctive personnel.

  3. Room temperature high-detectivity mid-infrared photodetectors based on black arsenic phosphorus.

    Science.gov (United States)

    Long, Mingsheng; Gao, Anyuan; Wang, Peng; Xia, Hui; Ott, Claudia; Pan, Chen; Fu, Yajun; Liu, Erfu; Chen, Xiaoshuang; Lu, Wei; Nilges, Tom; Xu, Jianbin; Wang, Xiaomu; Hu, Weida; Miao, Feng

    2017-06-01

    The mid-infrared (MIR) spectral range, pertaining to important applications, such as molecular "fingerprint" imaging, remote sensing, free space telecommunication, and optical radar, is of particular scientific interest and technological importance. However, state-of-the-art materials for MIR detection are limited by intrinsic noise and inconvenient fabrication processes, resulting in high-cost photodetectors requiring cryogenic operation. We report black arsenic phosphorus-based long-wavelength IR photodetectors, with room temperature operation up to 8.2 μm, entering the second MIR atmospheric transmission window. Combined with a van der Waals heterojunction, room temperature-specific detectivity higher than 4.9 × 10 9 Jones was obtained in the 3- to 5-μm range. The photodetector works in a zero-bias photovoltaic mode, enabling fast photoresponse and low dark noise. Our van der Waals heterojunction photodetectors not only exemplify black arsenic phosphorus as a promising candidate for MIR optoelectronic applications but also pave the way for a general strategy to suppress 1/ f noise in photonic devices.

  4. Communication outcomes for groups of children using cochlear implants enrolled in auditory-verbal, aural-oral, and bilingual-bicultural early intervention programs.

    Science.gov (United States)

    Dettman, Shani; Wall, Elizabeth; Constantinescu, Gabriella; Dowell, Richard

    2013-04-01

    The relative impact of early intervention approach on speech perception and language skills was examined in these 3 well-matched groups of children using cochlear implants. Eight children from an auditory verbal intervention program were identified. From a pediatric database, researchers blind to the outcome data, identified 23 children from auditory oral programs and 8 children from bilingual-bicultural programs with the same inclusion criteria and equivalent demographic factors. All child participants were male, had congenital profound hearing loss (pure tone average >80 dBHL), no additional disabilities, were within the normal IQ range, were monolingual English speakers, had no unusual findings on computed tomography/magnetic resonance imaging, and received hearing aids and cochlear implants at a similar age and before 4 years of age. Open-set speech perception (consonant-nucleus-consonant [CNC] words and Bamford-Kowal-Bench [BKB] sentences) and the Peabody Picture Vocabulary Test (PPVT) were administered. The mean age at cochlear implant was 1.7 years (range, 0.8-3.9; SD, 0.7), mean test age was 5.4 years (range, 2.5-10.1; SD, 1.7), and mean device experience was 3.7 years (range, 0.7-7.9; SD, 1.8). Results indicate mean CNC scores of 60%, 43%, and 24% and BKB scores of 77%, 77%, and 56% for the auditory-verbal (AV), aural-oral (AO), and bilingual-bicultural (BB) groups, respectively. The mean PPVT delay was 13, 19, and 26 months for AV, AO, and BB groups, respectively. Despite equivalent child demographic characteristics at the outset of this study, by 3 years postimplant, there were significant differences in AV, AO, and BB groups. Results support consistent emphasis on oral/aural input to achieve optimum spoken communication outcomes for children using cochlear implants.

  5. Egalisation adaptative et non invasive de la reponse temps-frequence d'une petite salle

    Science.gov (United States)

    Martin, Tristan

    In this research, we are interested in sound, environment wherein it propagates, the interaction between the sound wave and a transmission channel, and the changes induced by the components of an audio chain. The specific context studied is that of listening to music on loudspeakers. For the environment in which sound wave propagates, like for any transmission channel, there are mathematical functions used to characterize the changes induced by a channel on the signal therethrough. An electric signal serves as a input for a system, in this case consisting of an amplifier, a loudspeaker, and the room where the listening takes place, which according to its characteristics, returns as an output at the listening position, an altered sound wave. Frequency response, impulse response, transfer function, the mathematics used are no different from those used commonly for the characterization of a transmission channel or the expression of the outputs of a linear system to its inputs. Naturally, there is a purpose to this modeling exercise: getting the frequency response of the amplifier/loundspeaker/room chain makes possible its equalization. It is common in many contexts of listening to find a filter inserted into the audio chain between the source (Eg CD player) and the amplifier/loudspeaker that converts the electrical signal to an acoustic signal propagated in the room. This filter, called "equalizer" is intended to compensate the frequency effect of the components of the audio chain and the room on the sound signal that will be transmitted. Properties for designing this filter are derived from those of the audio chain. Although analytically rigorous, physical approach, focusing on physical modeling of the loudspeaker and the propagation equation of the acoustic wave is ill-suited to rooms with complex geometry and changing over time. The second approach, experimental modeling, and therefore that addressed in this work, ignores physical properties. The system audio chain

  6. Room Acoustics

    Science.gov (United States)

    Kuttruff, Heinrich; Mommertz, Eckard

    The traditional task of room acoustics is to create or formulate conditions which ensure the best possible propagation of sound in a room from a sound source to a listener. Thus, objects of room acoustics are in particular assembly halls of all kinds, such as auditoria and lecture halls, conference rooms, theaters, concert halls or churches. Already at this point, it has to be pointed out that these conditions essentially depend on the question if speech or music should be transmitted; in the first case, the criterion for transmission quality is good speech intelligibility, in the other case, however, the success of room-acoustical efforts depends on other factors that cannot be quantified that easily, not least it also depends on the hearing habits of the listeners. In any case, absolutely "good acoustics" of a room do not exist.

  7. Vision-based overlay of a virtual object into real scene for designing room interior

    Science.gov (United States)

    Harasaki, Shunsuke; Saito, Hideo

    2001-10-01

    In this paper, we introduce a geometric registration method for augmented reality (AR) and an application system, interior simulator, in which a virtual (CG) object can be overlaid into a real world space. Interior simulator is developed as an example of an AR application of the proposed method. Using interior simulator, users can visually simulate the location of virtual furniture and articles in the living room so that they can easily design the living room interior without placing real furniture and articles, by viewing from many different locations and orientations in real-time. In our system, two base images of a real world space are captured from two different views for defining a projective coordinate of object 3D space. Then each projective view of a virtual object in the base images are registered interactively. After such coordinate determination, an image sequence of a real world space is captured by hand-held camera with tracking non-metric measured feature points for overlaying a virtual object. Virtual objects can be overlaid onto the image sequence by taking each relationship between the images. With the proposed system, 3D position tracking device, such as magnetic trackers, are not required for the overlay of virtual objects. Experimental results demonstrate that 3D virtual furniture can be overlaid into an image sequence of the scene of a living room nearly at video rate (20 frames per second).

  8. Room temperature deformation of in-situ grown quasicrystals embedded in Al-based cast alloy

    Directory of Open Access Journals (Sweden)

    Boštjan Markoli

    2013-12-01

    Full Text Available An Al-based cast alloy containing Mn, Be and Cu has been chosen to investigate the room temperature deformation behavior of QC particles embedded in Al-matrix. Using LOM, SEM (equipped with EDS, conventional TEM with SAED and controlled tensile and compression tests, the deformation response of AlMn2Be2Cu2 cast alloy at room temperature has been examined. Alloy consisted of Al-based matrix, primary particles and eutectic icosahedral quasicrystalline (QC i-phase and traces of Θ-Al2Cu and Al10Mn3. Tensile and compression specimens were used for evaluation of mechanical response and behavior of QC i-phase articles embedded in Al-cast alloy. It has been established that embedded QC i-phase particles undergo plastic deformation along with the Al-based matrix even under severe deformation and have the response resembling that of the metallic materials by formation of typical cup-and-cone feature prior to failure. So, we can conclude that QC i-phase has the ability to undergo plastic deformation along with the Al-matrix to greater extent contrary to e.g. intermetallics such as Θ-Al2Cu for instance.

  9. Uncertainty of input data for room acoustic simulations

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Marbjerg, Gerd; Brunskog, Jonas

    2016-01-01

    Although many room acoustic simulation models have been well established, simulation results will never be accurate with inaccurate and uncertain input data. This study addresses inappropriateness and uncertainty of input data for room acoustic simulations. Firstly, the random incidence absorption...... and scattering coefficients are insufficient when simulating highly non-diffuse rooms. More detailed information, such as the phase and angle dependence, can greatly improve the simulation results of pressure-based geometrical and wave-based models at frequencies well below the Schroeder frequency. Phase...... summarizes potential advanced absorption measurement techniques that can improve the quality of input data for room acoustic simulations. Lastly, plenty of uncertain input data are copied from unreliable sources. Software developers and users should be careful when spreading such uncertain input data. More...

  10. Applying cost accounting to operating room staffing in otolaryngology: time-driven activity-based costing and outpatient adenotonsillectomy.

    Science.gov (United States)

    Balakrishnan, Karthik; Goico, Brian; Arjmand, Ellis M

    2015-04-01

    (1) To describe the application of a detailed cost-accounting method (time-driven activity-cased costing) to operating room personnel costs, avoiding the proxy use of hospital and provider charges. (2) To model potential cost efficiencies using different staffing models with the case study of outpatient adenotonsillectomy. Prospective cost analysis case study. Tertiary pediatric hospital. All otolaryngology providers and otolaryngology operating room staff at our institution. Time-driven activity-based costing demonstrated precise per-case and per-minute calculation of personnel costs. We identified several areas of unused personnel capacity in a basic staffing model. Per-case personnel costs decreased by 23.2% by allowing a surgeon to run 2 operating rooms, despite doubling all other staff. Further cost reductions up to a total of 26.4% were predicted with additional staffing rearrangements. Time-driven activity-based costing allows detailed understanding of not only personnel costs but also how personnel time is used. This in turn allows testing of alternative staffing models to decrease unused personnel capacity and increase efficiency. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  11. The operating room of the future: observations and commentary.

    Science.gov (United States)

    Satava, Richard M

    2003-09-01

    The Operating Room of the Future is a construct upon which to develop the next generation of operating environments for the patient, surgeon, and operating team. Analysis of the suite of visions for the Operating Room of the Future reveals a broad set of goals, with a clear overall solution to create a safe environment for high-quality healthcare. The vision, although planned for the future, is based upon iteratively improving and integrating current systems, both technology and process. This must become the Operating Room of Today, which will require the enormous efforts described. An alternative future of the operating room, based upon emergence of disruptive technologies, is also presented.

  12. Design and analysis of a BLPC vocoder-based adaptive feedback cancellation with probe noise

    DEFF Research Database (Denmark)

    Anand, Ankita; Kar, Asutosh; Swamy, M.N.S.

    2017-01-01

    a BLPC vocoderbased adaptive feedback canceller with probe noise with an objective of reducing the low-frequency bias in digital hearing-aids. A step-wise mathematical analysis of the proposed feedback canceller is presented employing the recursive least square and normalized least mean square adaptive......The band-limited linear predictive coding (BLPC) vocoder-based adaptive feedback cancellation (AFC) removes the high-frequency bias, while the low frequency bias persists between the desired input signal and the loudspeaker signal in the estimate of the feedback path. In this paper, we present...... algorithms. It is observed that the optimal solution of the feedback path is unbiased for an unshaped probe noise, but is biased for a shaped probe signal; the bias term does not consist of correlation between the desired input and the loudspeaker output. The identifiability conditions are analysed...

  13. Development of a plastic rotary heat exchanger for room-based ventilation in existing apartments

    DEFF Research Database (Denmark)

    Smith, Kevin Michael; Svendsen, Svend

    2015-01-01

    The existing building stock will likely undergo widespread energy renovations to meet future emissions targets. Single-room ventilation may enable the process due to its simple installation, low fan power, and potential for local heat recovery. A short plastic rotary heat exchanger is developed...... for single-room ventilation based on thermal design theory. Performance is predicted from correlations of dimensionless groups for regenerative heat exchangers, and this guides the selection of a polycarbonate honeycomb with small circular channels. Experiments quantify flows and determine temperature...... efficiencies at several ventilation rates while accounting for heat gains from motors and air leakage. The measured and modelled temperature efficiencies show adequate agreement and exceed 80% for a balanced nominal ventilation rate of 28m3/h. This result meets the development criteria but cannot validate...

  14. Measurement of low-frequency noise in rooms

    DEFF Research Database (Denmark)

    Pedersen, Steffen; Møller, Henrik; Persson-Waye, Kerstin

    2006-01-01

    Measurement of low-frequency noise in rooms is problematic due to standing wave patterns. The spatial variation in the sound pressure level can typically be as much as 20-30 dB. For assessment of annoyance from low-frequency noise in dwellings, it is important to measure a level close...... rooms. The sound pressure level was measured 1) in three-dimensional corners and 2) according to current Swedish and Danish measurement methods. Furthermore, the entire sound pressure distributions were measured by scanning. The Swedish and Danish measurement methods include a corner measurement...... to the highest level present in a room, rather than a room average level. In order to ensure representative noise measurements, different positions were investigated based on theoretical considerations and observations from numerical room simulations. In addition measurements were performed in three different...

  15. Mathematical Models for Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    1982-01-01

    A number of different models on the air distribution in rooms are introduced. This includes the throw model, a model on penetration length of a cold wall jet and a model for maximum velocity in the dimensioning of an air distribution system in highly loaded rooms and shows that the amount of heat...... removed from the room at constant penetration length is proportional to the cube of the velocities in the occupied zone. It is also shown that a large number of diffusers increases the amount of heat which may be removed without affecting the thermal conditions. Control strategies for dual duct and single...... duct systems are given and the paper is concluded by mentioning a computer-based prediction method which gives the velocity and temperature distribution in the whole room....

  16. Three-dimensional point-cloud room model in room acoustics simulations

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    acquisition and its representation with a 3D point-cloud model, as well as utilization of such a model for the room acoustics simulations. A room is scanned with a commercially available input device (Kinect for Xbox360) in two different ways; the first one involves the device placed in the middle of the room...... and rotated around the vertical axis while for the second one the device is moved within the room. Benefits of both approaches were analyzed. The device's depth sensor provides a set of points in a three-dimensional coordinate system which represents scanned surfaces of the room interior. These data are used...... to build a 3D point-cloud model of the room. Several models are created to meet requirements of different room acoustics simulation algorithms: plane fitting and uniform voxel grid for geometric methods and triangulation mesh for the numerical methods. Advantages of the proposed method over the traditional...

  17. Three-dimensional point-cloud room model for room acoustics simulations

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    acquisition and its representation with a 3D point-cloud model, as well as utilization of such a model for the room acoustics simulations. A room is scanned with a commercially available input device (Kinect for Xbox360) in two different ways; the first one involves the device placed in the middle of the room...... and rotated around the vertical axis while for the second one the device is moved within the room. Benefits of both approaches were analyzed. The device's depth sensor provides a set of points in a three-dimensional coordinate system which represents scanned surfaces of the room interior. These data are used...... to build a 3D point-cloud model of the room. Several models are created to meet requirements of different room acoustics simulation algorithms: plane fitting and uniform voxel grid for geometric methods and triangulation mesh for the numerical methods. Advantages of the proposed method over the traditional...

  18. A Field Evaluation of the Time-of-Detection Method to Estimate Population Size and Density for Aural Avian Point Counts

    Directory of Open Access Journals (Sweden)

    Mathew W. Alldredge

    2007-12-01

    Full Text Available The time-of-detection method for aural avian point counts is a new method of estimating abundance, allowing for uncertain probability of detection. The method has been specifically designed to allow for variation in singing rates of birds. It involves dividing the time interval of the point count into several subintervals and recording the detection history of the subintervals when each bird sings. The method can be viewed as generating data equivalent to closed capture-recapture information. The method is different from the distance and multiple-observer methods in that it is not required that all the birds sing during the point count. As this method is new and there is some concern as to how well individual birds can be followed, we carried out a field test of the method using simulated known populations of singing birds, using a laptop computer to send signals to audio stations distributed around a point. The system mimics actual aural avian point counts, but also allows us to know the size and spatial distribution of the populations we are sampling. Fifty 8-min point counts (broken into four 2-min intervals using eight species of birds were simulated. Singing rate of an individual bird of a species was simulated following a Markovian process (singing bouts followed by periods of silence, which we felt was more realistic than a truly random process. The main emphasis of our paper is to compare results from species singing at (high and low homogenous rates per interval with those singing at (high and low heterogeneous rates. Population size was estimated accurately for the species simulated, with a high homogeneous probability of singing. Populations of simulated species with lower but homogeneous singing probabilities were somewhat underestimated. Populations of species simulated with heterogeneous singing probabilities were substantially underestimated. Underestimation was caused by both the very low detection probabilities of all distant

  19. Auralisations with loudspeaker arrays from a phased combination of the image source method and acoustical radiosity

    DEFF Research Database (Denmark)

    Marbjerg, Gerd Høy

    2017-01-01

    In order to create a simulation tool that is well-suited for small rooms with low diffusion and highly absorbing ceilings, a new room acoustic simulation tool has been developed that combines a phased version of the image source with acoustical radiosity and that considers the angle dependence...... impulse response, because more directional information is available with acoustical radiosity. Small rooms with absorbing surfaces are tested, because this is the room type that PARISM is particularly useful for....

  20. Implementation and evaluation of an interprofessional simulation-based education program for undergraduate nursing students in operating room nursing education: a randomized controlled trial.

    Science.gov (United States)

    Wang, Rongmei; Shi, Nianke; Bai, Jinbing; Zheng, Yaguang; Zhao, Yue

    2015-07-09

    The present study was designed to implement an interprofessional simulation-based education program for nursing students and evaluate the influence of this program on nursing students' attitudes toward interprofessional education and knowledge about operating room nursing. Nursing students were randomly assigned to either the interprofessional simulation-based education or traditional course group. A before-and-after study of nursing students' attitudes toward the program was conducted using the Readiness for Interprofessional Learning Scale. Responses to an open-ended question were categorized using thematic content analysis. Nursing students' knowledge about operating room nursing was measured. Nursing students from the interprofessional simulation-based education group showed statistically different responses to four of the nineteen questions in the Readiness for Interprofessional Learning Scale, reflecting a more positive attitude toward interprofessional learning. This was also supported by thematic content analysis of the open-ended responses. Furthermore, nursing students in the simulation-based education group had a significant improvement in knowledge about operating room nursing. The integrated course with interprofessional education and simulation provided a positive impact on undergraduate nursing students' perceptions toward interprofessional learning and knowledge about operating room nursing. Our study demonstrated that this course may be a valuable elective option for undergraduate nursing students in operating room nursing education.

  1. A transparency model and its applications for simulation of reflector arrays and sound transmission (A)

    DEFF Research Database (Denmark)

    Christensen, Claus Lynge; Rindel, Jens Holger

    2006-01-01

    The paper describes a new method for simulating the frequency-dependent reflection and transmission of reflector arrays, and the frequency-dependent airborne sound insulation between rooms by means of a room acoustic computer model. The method makes use of a transparency method in the ray...... of the partition, and this is useful for the auralization of sound transmission through different building constructions. The acoustic properties like volume, reverberation time, and the area of the transmitting surfaces are included in the simulation....

  2. A highly reversible room-temperature lithium metal battery based on crosslinked hairy nanoparticles.

    KAUST Repository

    Choudhury, Snehashis; Mangal, Rahul; Agrawal, Akanksha; Archer, Lynden A

    2015-01-01

    Rough electrodeposition, uncontrolled parasitic side-reactions with electrolytes and dendrite-induced short-circuits have hindered development of advanced energy storage technologies based on metallic lithium, sodium and aluminium electrodes. Solid polymer electrolytes and nanoparticle-polymer composites have shown promise as candidates to suppress lithium dendrite growth, but the challenge of simultaneously maintaining high mechanical strength and high ionic conductivity at room temperature has so far been unmet in these materials. Here we report a facile and scalable method of fabricating tough, freestanding membranes that combine the best attributes of solid polymers, nanocomposites and gel-polymer electrolytes. Hairy nanoparticles are employed as multifunctional nodes for polymer crosslinking, which produces mechanically robust membranes that are exceptionally effective in inhibiting dendrite growth in a lithium metal battery. The membranes are also reported to enable stable cycling of lithium batteries paired with conventional intercalating cathodes. Our findings appear to provide an important step towards room-temperature dendrite-free batteries.

  3. A highly reversible room-temperature lithium metal battery based on crosslinked hairy nanoparticles.

    KAUST Repository

    Choudhury, Snehashis

    2015-12-04

    Rough electrodeposition, uncontrolled parasitic side-reactions with electrolytes and dendrite-induced short-circuits have hindered development of advanced energy storage technologies based on metallic lithium, sodium and aluminium electrodes. Solid polymer electrolytes and nanoparticle-polymer composites have shown promise as candidates to suppress lithium dendrite growth, but the challenge of simultaneously maintaining high mechanical strength and high ionic conductivity at room temperature has so far been unmet in these materials. Here we report a facile and scalable method of fabricating tough, freestanding membranes that combine the best attributes of solid polymers, nanocomposites and gel-polymer electrolytes. Hairy nanoparticles are employed as multifunctional nodes for polymer crosslinking, which produces mechanically robust membranes that are exceptionally effective in inhibiting dendrite growth in a lithium metal battery. The membranes are also reported to enable stable cycling of lithium batteries paired with conventional intercalating cathodes. Our findings appear to provide an important step towards room-temperature dendrite-free batteries.

  4. Design and modernization of control rooms according to new I and C systems based on HFE principles

    International Nuclear Information System (INIS)

    Rejas, Luis; Larraz, Javier; Ortega, Fernando

    2011-01-01

    The use of new digital I and C systems in the design of new nuclear power plants, as well as the modernization of existing facilities, implies relevant changes in the control room design. New I and C systems provide new features that affect the control room operating concept. Therefore, a detailed analysis is required to take into consideration all the operating and human factors aspects. Based on Tecnatom experience in the field, this article presents the methodological approach used as well as the most relevant aspects of this kind of project. (author)

  5. Design and modernization of control rooms according to new I and C systems based on HFE principles

    Energy Technology Data Exchange (ETDEWEB)

    Rejas, Luis; Larraz, Javier, E-mail: lrejas@tecnatom.e, E-mail: jlarraz@tecnatom.e [Tecnatom S.A., San Sebastian de los Reyes, Madrid (Spain). New Control Room Design Dept.; Ortega, Fernando, E-mail: fortega@tecnatom.e [Tecnatom S.A., San Sebastian de los Reyes, Madrid (Spain). Control Room and Simulation Dept.

    2011-07-01

    The use of new digital I and C systems in the design of new nuclear power plants, as well as the modernization of existing facilities, implies relevant changes in the control room design. New I and C systems provide new features that affect the control room operating concept. Therefore, a detailed analysis is required to take into consideration all the operating and human factors aspects. Based on Tecnatom experience in the field, this article presents the methodological approach used as well as the most relevant aspects of this kind of project. (author)

  6. Operating room fires in periocular surgery.

    Science.gov (United States)

    Connor, Michael A; Menke, Anne M; Vrcek, Ivan; Shore, John W

    2018-06-01

    A survey of ophthalmic plastic and reconstructive surgeons as well as seven-year data regarding claims made to the Ophthalmic Mutual Insurance Company (OMIC) is used to discuss operating room fires in periocular surgery. A retrospective review of all closed claim operating room fires submitted to OMIC was performed. A survey soliciting personal experiences with operating room fires was distributed to all American Society of Oculoplastic and Reconstructive Surgeons. Over the last 2 decades, OMIC managed 7 lawsuits resulting from an operating room fire during periocular surgery. The mean settlement per lawsuit was $145,285 (range $10,000-474,994). All six patients suffered burns to the face, and three required admission to a burn unit. One hundred and sixty-eight surgeons participated in the online survey. Approximately 44% of survey respondents have experienced at least one operating room fire. Supplemental oxygen was administered in 88% of these cases. Most surgical fires reported occurred in a hospital-based operating room (59%) under monitored anesthesia care (79%). Monopolar cautery (41%) and thermal, high-temperature cautery (41%) were most commonly reported as the inciting agents. Almost half of the patients involved in a surgical fire experienced a complication from the fire (48%). Sixty-nine percent of hospital operating rooms and 66% of ambulatory surgery centers maintain an operating room fire prevention policy. An intraoperative fire can be costly for both the patient and the surgeon. Ophthalmic surgeons operate in an oxygen rich and therefore flammable environment. Proactive measures can be undertaken to reduce the incidence of surgical fires periocular surgery; however, a fire can occur at any time and the entire operating room team must be constantly vigilant to prevent and manage operating room fires.

  7. Sweet Spot Size in Virtual Sound Reproduction: A Temporal Analysis

    DEFF Research Database (Denmark)

    Lacouture Parodi, Yesenia; Rubak, Per

    2009-01-01

    The influence of head misalignments on the performance of binaural reproduction systems through loudspeakers is often evaluated in the frequency domain. The changes in magnitude give us an idea of how much of the crosstalk is leaked into the direct signal and therefore a sweet spot performance can......-correlation we estimate the interaural time delay and define a sweet spot. The analysis is based on measurements carried out on 21 different loudspeaker configurations, including two- and four-channels arrangements. Results show that closely spaced loudspeakers are more robust to lateral displacements than wider...... span angles. Additionally, the sweet spot as a function of head rotations increases systematically when the loudspeakers are placed at elevated positions....

  8. Room temperature creep in metals and alloys

    Energy Technology Data Exchange (ETDEWEB)

    Deibler, Lisa Anne [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Materials Characterization and Performance

    2014-09-01

    Time dependent deformation in the form of creep and stress relaxation is not often considered a factor when designing structural alloy parts for use at room temperature. However, creep and stress relaxation do occur at room temperature (0.09-0.21 Tm for alloys in this report) in structural alloys. This report will summarize the available literature on room temperature creep, present creep data collected on various structural alloys, and finally compare the acquired data to equations used in the literature to model creep behavior. Based on evidence from the literature and fitting of various equations, the mechanism which causes room temperature creep is found to include dislocation generation as well as exhaustion.

  9. Ge-Based Spin-Photodiodes for Room-Temperature Integrated Detection of Photon Helicity

    KAUST Repository

    Rinaldi, Christian

    2012-05-02

    Spin-photodiodes based on Fe/MgO/Ge(001) heterostructures are reported. These devices perform the room-temperature integrated electrical detection of the spin polarization of a photocurrent generated by circularly polarized photons with a wavelength of 1300 nm, for light pulses with intensity I 0 down to 200 μW. A forward and reverse-biased average photocurrent variation of 5.9% is measured for the complete reversal of the incident light helicity. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Room with a View: Ethical Encounters in Room 13

    Science.gov (United States)

    Grube, Vicky

    2012-01-01

    In this article, the author describes ethical encounters in Room 13, a schoolroom where children made what they wanted, posed their own questions, and ran an art room like a small business. In Room 13 children had the responsibility to maintain all aspects of the art studio. Specific decisions fell to an annually elected management team, a small…

  11. Continuous-Wave Operation of GaN Based Multi-Quantum-Well Laser Diode at Room Temperature

    International Nuclear Information System (INIS)

    Li-Qun, Zhang; Shu-Ming, Zhang; Hui, Yang; Lian, Ji; Jian-Jun, Zhu; Zong-Shun, Liu; De-Gang, Zhao; De-Sheng, Jiang; Li-Hong, Duan; Hai, Wang; Yong-Sheng, Shi; Su-Ying, Liu; Jun-Wu, Liang; Qing, Cao; Liang-Hui, Chen

    2008-01-01

    Room-temperature operation of cw GaN based multi-quantum-well laser diodes (LDs) is demonstrated. The LD structure is grown on a sapphire (0001) substrate by metalorganic chemical vapour deposition. A 2.5μm × 800μm ridge waveguide structure is fabricated. The electrical and optical characteristics of the laser diode under direct current injection at room temperature are investigated. The threshold current and voltage of the LD under cw operation are 110 mA and 10.5 V, respectively. Thermal induced series resistance decrease and emission wavelength red-shift are observed as the injection current is increased. The full width at half maximum for the parallel and perpendicular far field pattern (FFP) are 12° and 32°, respectively

  12. Operating Room Fires and Surgical Skin Preparation.

    Science.gov (United States)

    Jones, Edward L; Overbey, Douglas M; Chapman, Brandon C; Jones, Teresa S; Hilton, Sarah A; Moore, John T; Robinson, Thomas N

    2017-07-01

    Operating room fires are "never events" that remain an under-reported source of devastating complications. One common set-up that promotes fires is the use of surgical skin preparations combined with electrosurgery and oxygen. Limited data exist examining the incidence of fires and surgical skin preparations. A standardized, ex vivo model was created with a 15 × 15 cm section of clipped porcine skin. An electrosurgical "Bovie" pencil was activated for 2 seconds on 30 Watts coagulation mode in 21% oxygen (room air), both immediately and 3 minutes after skin preparation application. Skin preparations with and without alcohol were tested, and were applied with and without pooling. Alcohol-based skin preparations included 70% isopropyl alcohol (IPA) with 2% chlorhexidine gluconate, 74% IPA with 0.7% iodine povacrylex, and plain 70% IPA. No fires occurred with nonalcohol-based preparations (p fires occurred in 38% (23 of 60) at 0 minutes and 27% (16 of 60) at 3 minutes. Alcohol-based skin preparations fuel operating room fires in common clinical scenarios. Following manufacturer guidelines and allowing 3 minutes for drying, surgical fires were still created in 1 in 10 cases without pooling and more than one-quarter of cases with pooling. Surgeons can decrease the risk of an operating room fire by using nonalcohol-based skin preparations or avoiding pooling of the preparation solution. Published by Elsevier Inc.

  13. Facile fabrication of CNT-based chemical sensor operating at room temperature

    Science.gov (United States)

    Sheng, Jiadong; Zeng, Xian; Zhu, Qi; Yang, Zhaohui; Zhang, Xiaohua

    2017-12-01

    This paper describes a simple, low cost and effective route to fabricate CNT-based chemical sensors, which operate at room temperature. Firstly, the incorporation of silk fibroin in vertically aligned CNT arrays (CNTA) obtained through a thermal chemical vapor deposition (CVD) method makes the direct removal of CNT arrays from substrates without any rigorous acid or sonication treatment feasible. Through a simple one-step in situ polymerization of anilines, the functionalization of CNT arrays with polyaniline (PANI) significantly improves the sensing performance of CNT-based chemical sensors in detecting ammonia (NH3) and hydrogen chloride (HCl) vapors. Chemically modified CNT arrays also show responses to organic vapors like menthol, ethyl acetate and acetone. Although the detection limits of chemically modified CNT-based chemical sensors are of the same orders of magnitudes reported in previous studies, these CNT-based chemical sensors show advantages of simplicity, low cost and energy efficiency in preparation and fabrication of devices. Additionally, a linear relationship between the relative sensitivity and concentration of analyte makes precise estimations on the concentrations of trace chemical vapors possible.

  14. Ti-based bulk metallic glass with high cold workability at room temperature

    International Nuclear Information System (INIS)

    Park, J.M.; Park, J.S.; Kim, J.H.; Lee, M.H.; Kim, D.H.; Kim, W.T.

    2005-01-01

    The cold workability of Ti-based bulk metallic glasses (BMGs) have been investigated. Ti 45 Zr 16 Be 20 Cu 10 Ni 9 BMG with a large compressive plastic strain of 4.7% shows a high cold workability, i.e. total reduction ratio of 50% by cold rolling at room temperature. The multiple shear bands formed during rolling are effective in enhancing the plasticity. The cold rolled Ti 45 Zr 16 Be 20 Cu 10 Ni 9 BMG (reduction ratio: 30%) exhibits a large plastic strain of ∝14%. (orig.)

  15. Prepare to protect: Operating and maintaining a tornado safe room.

    Science.gov (United States)

    Herseth, Andrew; Goldsmith-Grinspoon, Jennifer; Scott, Pataya

    2017-06-01

    Operating and maintaining a tornado safe room can be critical to the effective continuity of business operations because a firm's most valuable asset is its people. This paper describes aspects of operations and maintenance (O&M) for existing tornado safe rooms as well as a few planning and design aspects that affect the ultimate operation of a safe room for situations where a safe room is planned, but not yet constructed. The information is based on several Federal Emergency Management Agency safe room publications that provide guidance on emergency management and operations, as well as the design and construction of tornado safe rooms.

  16. Evaluation of in vitro antibacterial effect of room curing polymethylmethacrylate material adding nano-silver base inorganic antibacterial agents

    International Nuclear Information System (INIS)

    Jia Chunli; Wang Xiaorong; Zhang Citong; Sun Shiqun; Yang Yun

    2012-01-01

    Objective: To investigate the antibacterial effect of room curing polymethylmethacrylate (PMMA) material adding nano-silver base inorganic antibacterial agent and to detect the changes of its mechanical property. Methods: Nano-silver base inorganic antibacterial agent was added to the room curing PMMA material in the range of 0.5% -3.0% at an interval of 0.5% by ball milling specimen. Antibacterial rates of the specimens were detected by film method. Bending strength, impact strength, and wear resistance of the specimens were respectively detected on electronic universal testing machine, impact test machine and friction and wear test machine. Results: The antibacterial rates of Streptococcus mutans and Candida albicans were more than 50% when antibiotics content was 1.0% . The antibacterial rates of Streptococcus mutans and Candida albicans were more than 90% when the antibiotics content was 2.5% . The three mechanical properties were increased compared with control group when the antibacterial agents were in the range of 1.0% -1.5% . Then the three mechanical properties were decreased with the increasing of antimicrobial concentration. When the antibiotics content was 2.0% , the wear resistance had significant difference compared with control group (P<0.05); when the antibiotics content was 2.5% , the bending strength and impact strength had significant difference compared with control group (P<0.05). Conclusion: The antibacterial effect of room curing PMMA adding nano-silver base inorganic antibacterial agent is ideal. The antibacterial rate is increased gradually with the increasing content of antibacterial agents. There is no significant effect on the mechanical properties of room curing PMMA material, but the antibacterial effects are satisfied when the content of antibacterial agents is 2.0% . (authors)

  17. On isocentre adjustment and quality control in linear accelerator based radiosurgery with circular collimators and room lasers

    Energy Technology Data Exchange (ETDEWEB)

    Treuer, H. [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany). E-mail: h.treuer at uni-koeln.de; Hoevels, M.; Luyken, K.; Gierich, A.; Sturm, V. [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Kocher, M.; Mueller, R.-P. [Department of Radiotherapy, University of Cologne, Cologne (Germany)

    2000-08-01

    We have developed a densitometric method for measuring the isocentric accuracy and the accuracy of marking the isocentre position for linear accelerator based radiosurgery with circular collimators and room lasers. Isocentric shots are used to determine the accuracy of marking the isocentre position with room lasers and star shots are used to determine the wobble of the gantry and table rotation movement, the effect of gantry sag, the stereotactic collimator alignment, and the minimal distance between gantry and table rotation axes. Since the method is based on densitometric measurements, beam spot stability is implicitly tested. The method developed is also suitable for quality assurance and has proved to be useful in optimizing isocentric accuracy. The method is simple to perform and only requires a film box and film scanner for instrumentation. Thus, the method has the potential to become widely available and may therefore be useful in standardizing the description of linear accelerator based radiosurgical systems. (author)

  18. On isocentre adjustment and quality control in linear accelerator based radiosurgery with circular collimators and room lasers

    International Nuclear Information System (INIS)

    Treuer, H.; Kocher, M.; Mueller, R.-P.

    2000-01-01

    We have developed a densitometric method for measuring the isocentric accuracy and the accuracy of marking the isocentre position for linear accelerator based radiosurgery with circular collimators and room lasers. Isocentric shots are used to determine the accuracy of marking the isocentre position with room lasers and star shots are used to determine the wobble of the gantry and table rotation movement, the effect of gantry sag, the stereotactic collimator alignment, and the minimal distance between gantry and table rotation axes. Since the method is based on densitometric measurements, beam spot stability is implicitly tested. The method developed is also suitable for quality assurance and has proved to be useful in optimizing isocentric accuracy. The method is simple to perform and only requires a film box and film scanner for instrumentation. Thus, the method has the potential to become widely available and may therefore be useful in standardizing the description of linear accelerator based radiosurgical systems. (author)

  19. Operating Room Performance Improves after Proficiency-Based Virtual Reality Cataract Surgery Training

    DEFF Research Database (Denmark)

    Thomsen, Ann Sofia Skou; Bach-Holm, Daniella; Kjærbo, Hadi

    2017-01-01

    PURPOSE: To investigate the effect of virtual reality proficiency-based training on actual cataract surgery performance. The secondary purpose of the study was to define which surgeons benefit from virtual reality training. DESIGN: Multicenter masked clinical trial. PARTICIPANTS: Eighteen cataract...... surgeons with different levels of experience. METHODS: Cataract surgical training on a virtual reality simulator (EyeSi) until a proficiency-based test was passed. MAIN OUTCOME MEASURES: Technical performance in the operating room (OR) assessed by 3 independent, masked raters using a previously validated...... task-specific assessment tool for cataract surgery (Objective Structured Assessment of Cataract Surgical Skill). Three surgeries before and 3 surgeries after the virtual reality training were video-recorded, anonymized, and presented to the raters in random order. RESULTS: Novices (non...

  20. Modern control room design experience and speculation

    International Nuclear Information System (INIS)

    Smith, J.E.

    1993-01-01

    Can operators trained to use conventional control panels readily adapt to CRT based control rooms? Does automation make the design of good man-machine interfaces more or less difficult? In a conventional, hard-wired control room is the operator's peripheral vision always an asset and how can one do better in a CRT based control room? Are Expert System assisted man-machine interfaces a boon or a bust? This paper explores these questions in the light of actual experience with advanced power plant control environments. This paper discusses how automation has in fact simplified the problem of ensuring that the operator has at all times a clear understanding of the plant state. The author contends that conventional hard-wired control rooms are very poor at providing the operator with a good overview of the plant status particularly under startup, or upset conditions and that CRT-based control rooms offer an opportunity for improvement. Experience with some early attempts at this are discussed together with some interesting proposals from other authors. Finally the paper discusses the experience to date with expert system assisted man-machine interfaces. Although promising for the future progress has been slow. The amount of knowledge research required is often formidable and consequently costly. Often when an adequate knowledge base is finally acquired it turns out to be better to use it to increase the level of automation and thus simplify the operator's task. The risks are not any greater and automation offers more consistent operation. It is important also to carefully distinguish between expert system assisted display selection and expert system operator guidance. The first is intended to help the operator in his quest for information. The second attempts to guide the operator actions. The good and the bad points of each of these approaches is discussed

  1. Hypoxia Room

    Data.gov (United States)

    Federal Laboratory Consortium — The Hypoxia Room is a 8x8x8 ft. clear vinyl plastic and aluminum frame construction enclosure located within USAREIM laboratory 028. The Hypoxia Room (manufactured...

  2. Neutron absorbing room temperature vulcanizable silicone rubber compositions

    International Nuclear Information System (INIS)

    Zoch, H.L.

    1979-01-01

    A neutron absorbing composition is described and consists of a one-component room temperature vulcanizable silicone rubber composition or a two-component room temperature vulcanizable silicone rubber composition in which the composition contains from 25 to 300 parts by weight based on the base silanol or vinyl containing diorganopolysiloxane polymer of a boron compound or boron powder as the neutron absorbing ingredient. An especially useful boron compound in this application is boron carbide. 20 claims

  3. Mathematical Models for Room Air Distribution - Addendum

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    1982-01-01

    A number of different models on the air distribution in rooms are introduced. This includes the throw model, a model on penetration length of a cold wall jet and a model for maximum velocity in the dimensioning of an air distribution system in highly loaded rooms and shows that the amount of heat...... removed from the room at constant penetration length is proportional to the cube of the velocities in the occupied zone. It is also shown that a large number of diffusers increases the amount of heat which may be removed without affecting the thermal conditions. Control strategies for dual duct and single...... duct systems are given and the paper is concluded by mentioning a computer-based prediction method which gives the velocity and temperature distribution in the whole room....

  4. Effect of Room Ventilation Rates in Rodent Rooms with Direct-Exhaust IVC Systems.

    Science.gov (United States)

    Geertsema, Roger S; Lindsell, Claire E

    2015-09-01

    When IVC are directly exhausted from a rodent housing room, the air quality of the room can become independent of the intracage air quality and may reduce the need for high room ventilation rates. This study assessed the effect of decreasing the ventilation rate in rodent rooms using direct-exhaust IVC systems. The study was conducted over 16 wk and compared conditions in 8 rodent rooms that had ventilation rates of 5 to 6 air changes per hour (ACH) with those in rooms at 10 to 12 ACH. At the low ventilation rate, rooms had higher CO₂ concentrations, higher dew point temperature, and lower particulate levels and spent a greater percentage of time above the temperature set point than did rooms at the high rate. The levels of allergens and endotoxins in room air were the same regardless of the ventilation rate. Differences seen in parameters within cages at the 2 ventilation rates were operationally irrelevant. We detected no total volatile organic compounds in the room that were attributable to ammonia, regardless of the ventilation rate. Clearing the air of ethanol after a spill took longer at the low compared with high rate. However, ethanol clearance was faster at the low rate when the demand-control system was activated than at the high ventilation rate alone. Air quality in the room and in the cages were acceptable with room ventilation rates of 5 to 6 ACH in rodent rooms that use direct-exhaust IVC systems.

  5. Discussion on control room habitability assessment

    International Nuclear Information System (INIS)

    Li Bing; Chen Yingying; Xiao Jun; Yang Duanjie; Cui Hao

    2014-01-01

    The discussion on control room envelope integrity, source term analysis in habitability assessments and other impact factors for dose consequence is provided combined with regulatory requirements and the current status of domestic NPPs. Considering that the infiltration is an important factor for control room habitability assessment, CRE integrity test should be performed to demonstrate the CRE's infiltration characteristics. The consequence assessment should be performed based on different DBAs and different pathways, such as pathways internal to the plant. (authors)

  6. From Smart Rooms to Smart Hotels

    OpenAIRE

    Petrevska, Biljana; Cingoski, Vlatko; Gelev, Saso

    2016-01-01

    This paper gives an overview of a potential path that new hotels have to satisfy to improve their status from a hotel with smart rooms towards a full-scale smart hotel facility. It presents a possible transitional way including innovative applications based on modern information technology for ambient settings in the domain of hotel industry that aims to improve the quality of offered services towards clients, starting from the present level of smart rooms. The main objective i...

  7. The Operating Room of the Future Versus the Future of the Operating Room.

    Science.gov (United States)

    Kassam, Amin B; Rovin, Richard A; Walia, Sarika; Chakravarthi, Srikant; Celix, Juanita; Jennings, Jonathan; Khalili, Sammy; Gonen, Lior; Monroy-Sosa, Alejandro; Fukui, Melanie B

    2017-06-01

    Technological advancement in the operating room is evolving into a dynamic system mirroring that of the aeronautics industry. Through data visualization, information is continuously being captured, collected, and stored on a scalable informatics platform for rapid, intuitive, iterative learning. The authors believe this philosophy (paradigm) will feed into an intelligent informatics domain fully accessible to all and geared toward precision, cell-based therapy in which tissue can be targeted and interrogated in situ. In the future, the operating room will be a venue that facilitates this real-time tissue interrogation, which will guide in situ therapeutics to restore the state of health. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Room temperature superconductors

    International Nuclear Information System (INIS)

    Sleight, A.W.

    1995-01-01

    If the Holy Grail of room temperature superconductivity could be achieved, the impact on could be enormous. However, a useful room temperature superconductor for most applications must possess a T c somewhat above room temperature and must be capable of sustaining superconductivity in the presence of magnetic fields while carrying a significant current load. The authors will return to the subject of just what characteristics one might seek for a compound to be a room temperature superconductor. 30 refs., 3 figs., 1 tab

  9. Web Based Room Monitoring System Using Webcam

    Directory of Open Access Journals (Sweden)

    Tole Sutikno

    2008-04-01

    Full Text Available A security has become very important along with the increasing number of crime cases. If some security system fails, there is a need for a mechanism that capable in recording the criminal act. Therefore, it can be used for investigation purpose of the authorities. The objective of this research is to develop a security system using video streaming that able to monitor in real-time manner, display movies in a browser, and record a video as triggered by a sensor. This monitoring system comprises of two security level camera as a video recorder of special events based on infrared sensor that is connected to a microcontroller via serial communication and camera as a real-time room monitor. The hardware system consists of infrared sensor circuit to detect special events that is serially communicated to an AT89S51 microcontroller that controls the system to perform recording process, and the software system consists of a server that displaying video streaming in a webpage and a video recorder. The software for video recording and server camera uses Visual Basic 6.0 and for video streaming uses PHP 5.1.6. As the result, the system can be used to record special events that it is wanted, and can displayed video streaming in a webpage using LAN infrastructure.

  10. Quantum interference effects at room temperature in OPV-based single-molecule junctions

    DEFF Research Database (Denmark)

    Arroyo, Carlos R.; Frisenda, Riccardo; Moth-Poulsen, Kasper

    2013-01-01

    Interference effects on charge transport through an individual molecule can lead to a notable modulation and suppression on its conductance. In this letter, we report the observation of quantum interference effects occurring at room temperature in single-molecule junctions based on oligo(3......)-phenylenevinylene (OPV3) derivatives, in which the central benzene ring is coupled to either para- or meta-positions. Using the break-junction technique, we find that the conductance for a single meta-OPV3 molecule wired between gold electrodes is one order of magnitude smaller than that of a para-OPV3 molecule...

  11. Indium oxide octahedrons based on sol–gel process enhance room temperature gas sensing performance

    Energy Technology Data Exchange (ETDEWEB)

    Mu, Xiaohui [Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, Shandong (China); Chen, Changlong, E-mail: chem.chencl@hotmail.com [Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, Shandong (China); Han, Liuyuan [Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, Shandong (China); Shao, Baiqi [State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Wei, Yuling [Instrumental Analysis Center, Qilu University of Technology, Jinan 250353, Shandong (China); Liu, Qinglong; Zhu, Peihua [Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, Shandong (China)

    2015-07-15

    Highlights: • In{sub 2}O{sub 3} octahedron films are prepared based on sol–gel technique for the first time. • The preparation possesses merits of low temperature, catalyst-free and large production. • It was found that the spin-coating process in film fabrication was key to achieve the octahedrons. • The In{sub 2}O{sub 3} octahedrons could significantly enhance room temperature NO{sub 2} gas sensing performance. - Abstract: Indium oxide octahedrons were prepared on glass substrates through a mild route based on sol–gel technique. The preparation possesses characteristics including low temperature, catalyst-free and large production, which is much distinguished from the chemical-vapor-deposition based methods that usually applied to prepare indium oxide octahedrons. Detailed characterization revealed that the indium oxide octahedrons were single crystalline, with {1 1 1} crystal facets exposed. It was found that the spin-coating technique was key for achieving the indium oxide crystals with octahedron morphology. The probable formation mechanism of the indium oxide octahedrons was proposed based on the experiment results. Room temperature NO{sub 2} gas sensing measurements exhibited that the indium oxide octahedrons could significantly enhance the sensing performance in comparison with the plate-like indium oxide particles that prepared from the dip-coated gel films, which was attributed to the abundant sharp edges and tips as well as the special {1 1 1} crystal facets exposed that the former possessed. Such a simple wet-chemical based method to prepare indium oxide octahedrons with large-scale production is promising to provide the advanced materials that can be applied in wide fields like gas sensing, solar energy conversion, field emission, and so on.

  12. Indium oxide octahedrons based on sol–gel process enhance room temperature gas sensing performance

    International Nuclear Information System (INIS)

    Mu, Xiaohui; Chen, Changlong; Han, Liuyuan; Shao, Baiqi; Wei, Yuling; Liu, Qinglong; Zhu, Peihua

    2015-01-01

    Highlights: • In 2 O 3 octahedron films are prepared based on sol–gel technique for the first time. • The preparation possesses merits of low temperature, catalyst-free and large production. • It was found that the spin-coating process in film fabrication was key to achieve the octahedrons. • The In 2 O 3 octahedrons could significantly enhance room temperature NO 2 gas sensing performance. - Abstract: Indium oxide octahedrons were prepared on glass substrates through a mild route based on sol–gel technique. The preparation possesses characteristics including low temperature, catalyst-free and large production, which is much distinguished from the chemical-vapor-deposition based methods that usually applied to prepare indium oxide octahedrons. Detailed characterization revealed that the indium oxide octahedrons were single crystalline, with {1 1 1} crystal facets exposed. It was found that the spin-coating technique was key for achieving the indium oxide crystals with octahedron morphology. The probable formation mechanism of the indium oxide octahedrons was proposed based on the experiment results. Room temperature NO 2 gas sensing measurements exhibited that the indium oxide octahedrons could significantly enhance the sensing performance in comparison with the plate-like indium oxide particles that prepared from the dip-coated gel films, which was attributed to the abundant sharp edges and tips as well as the special {1 1 1} crystal facets exposed that the former possessed. Such a simple wet-chemical based method to prepare indium oxide octahedrons with large-scale production is promising to provide the advanced materials that can be applied in wide fields like gas sensing, solar energy conversion, field emission, and so on

  13. Control room habitability study - findings and recommendations

    International Nuclear Information System (INIS)

    Driscoll, J.W.

    1987-01-01

    The Advisory Committee on Reactor Safeguards (ACRS) has raised a number of concerns related to control room habitability and has recommended actions which they believe could alleviate these concerns. As a result of the ACRS's concerns, the US Nuclear Regulatory Commission's (NRC) Office of Nuclear Reactor Regulation (NRR) in conjunction with the Offices of Research and Inspection and Enforcement, and the NRC regional offices, embarked upon a program to reevaluate Control Room Habitability. Argonne National Laboratory was contracted by the NRC to perform a Control Room Habitability Study on twelve licensed power reactors. The plants selected for the study were chosen based upon architect engineer, nuclear steam system supplier, utility, and plant location. The major findings of this study are included in this report along with generic recommendations of the review team that apply to control room HVAC systems. Although the study is not complete, at the time of publication of this report, the results obtained to date should be useful to persons responsible for Control Room Habitability in evaluating their own systems

  14. P-type sub-tungsten-oxide based urchin-like nanostructure for superior room temperature alcohol sensor

    Science.gov (United States)

    Yao, Yao; Yin, Mingli; Yan, Junqing; Liu, Shengzhong (Frank)

    2018-05-01

    Nanowires assembled sub-WO3 urchin-like nanostructures have been fabricated via a solvothermal method. The detailed structure and morphology features were characterized by X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM) and transmission electron microscopy (TEM). The results reveal that the individual nanowires are grown along the [0 0 1] direction, and assembled together to form an urchin-like nanostructure. Sensing performance of the sub-WO3 was investigated toward alcohol vapor. At room temperature, the sensor devices based on the WO3-x exhibit significantly higher sensitivity comparing to that of the stoichiometric WO3. The superior sensing performance of this WO3-x sensor is ascribed to the large specific surface area and abundant oxygen vacancies. The obvious enhancement of the gas sensing property can be very useful for the future design and development of room temperature gas sensors for other volatile organic compounds.

  15. Control room philosophy: Principles of control room design and control room work; Kontrollrumsfilosofi: Principer foer kontrollrumsutformning och kontrollrumsarbete

    Energy Technology Data Exchange (ETDEWEB)

    Skriver, Jan; Ramberg, Jasmine; Allwin, Pernilla [Scandpower Risk Management AB, Uppsala (Sweden)

    2006-01-15

    In order to provide insights for improvement of work in control rooms several factors have to be considered. Knowledge of principles including control room philosophies will guide the recommended improvements. In addition to knowledge about specific principles an advantage for an organization can be an understanding of similarities and policies used in other high risk industry. The report has been developed on the basis of a document analysis of international standards and other guiding documents. (NUREG 0711, ISO 11064, ISO 6385, IEC 60964). In addition to the document analysis which has strived to compare the documents to see similarities in important principals, experience from working with control room design, modifications and evaluations in other high risk industries has pervaded the report. Important principles have been identified which are recommended to be included in a control room philosophy. Many of these are similar to the principles identified in the international standards. An additional principal which is regarded as important is the utilization of Key Performance Indicators (KPI) which can be used as a measure to target preventative means. Further more it is critical that the control room philosophy is easy to access and comprehend for all users. One of the challenges that remain after having developed a control room philosophy is how to utilize it in the daily work situation. It is vital that the document remains as a living document, guiding the continual improvement of the control room in the various life cycle stages.

  16. Gallium-Based Room-Temperature Liquid Metals: Actuation and Manipulation of Droplets and Flows

    Directory of Open Access Journals (Sweden)

    Leily Majidi

    2017-08-01

    Full Text Available Gallium-based room-temperature liquid metals possess extremely valuable properties, such as low toxicity, low vapor pressure, and high thermal and electrical conductivity enabling them to become suitable substitutes for mercury and beyond in wide range of applications. When exposed to air, a native oxide layer forms on the surface of gallium-based liquid metals which mechanically stabilizes the liquid. By removing or reconstructing the oxide skin, shape and state of liquid metal droplets and flows can be manipulated/actuated desirably. This can occur manually or in the presence/absence of a magnetic/electric field. These methods lead to numerous useful applications such as soft electronics, reconfigurable devices, and soft robots. In this mini-review, we summarize the most recent progresses achieved on liquid metal droplet generation and actuation of gallium-based liquid metals with/without an external force.

  17. Taking account of human factors in control-room design

    International Nuclear Information System (INIS)

    Dien, Y.; Montmayeul, R.

    1995-07-01

    Since the Three Mile Island accident two ways for improving the Human-Machine Interface have mainly been followed: the development of computerized operator aids in existing control-rooms and the design of advanced control-rooms. Insufficient attention paid to human factors in the design of operator aids has generally led to these aids being neglected or unused by their potential users. While for the design of advanced control-rooms efforts have been made for dealing with human factors in more extensive way. Based upon this experience, a general method for taking account of human factors in a control-room design has been devised and is described in this paper. (author)

  18. Synthesis of Directional Sources Using Wave Field Synthesis, Possibilities, and Limitations

    Directory of Open Access Journals (Sweden)

    Corteel E

    2007-01-01

    Full Text Available The synthesis of directional sources using wave field synthesis is described. The proposed formulation relies on an ensemble of elementary directivity functions based on a subset of spherical harmonics. These can be combined to create and manipulate directivity characteristics of the synthesized virtual sources. The WFS formulation introduces artifacts in the synthesized sound field for both ideal and real loudspeakers. These artifacts can be partly compensated for using dedicated equalization techniques. A multichannel equalization technique is shown to provide accurate results thus enabling for the manipulation of directional sources with limited reconstruction artifacts. Applications of directional sources to the control of the direct sound field and the interaction with the listening room are discussed.

  19. Ergonomic evaluation model of operational room based on team performance

    Directory of Open Access Journals (Sweden)

    YANG Zhiyi

    2017-05-01

    Full Text Available A theoretical calculation model based on the ergonomic evaluation of team performance was proposed in order to carry out the ergonomic evaluation of the layout design schemes of the action station in a multitasking operational room. This model was constructed in order to calculate and compare the theoretical value of team performance in multiple layout schemes by considering such substantial influential factors as frequency of communication, distance, angle, importance, human cognitive characteristics and so on. An experiment was finally conducted to verify the proposed model under the criteria of completion time and accuracy rating. As illustrated by the experiment results,the proposed approach is conductive to the prediction and ergonomic evaluation of the layout design schemes of the action station during early design stages,and provides a new theoretical method for the ergonomic evaluation,selection and optimization design of layout design schemes.

  20. Room temperature ferromagnetism of tin oxide nanocrystal based on synthesis methods

    Energy Technology Data Exchange (ETDEWEB)

    Sakthiraj, K.; Hema, M. [Department of Physics, Kamaraj College of Engineering and Technology, Virudhunagar 626001, Tamil Nadu (India); Balachandrakumar, K. [Department of Physics, Raja Doraisingam Government Arts College, Sivagangai 630561, Tamil Nadu (India)

    2016-04-15

    The experimental conditions used in the preparation of nanocrystalline oxide materials play an important role in the room temperature ferromagnetism of the product. In the present work, a comparison was made between sol–gel, microwave assisted sol–gel and hydrothermal methods for preparing tin oxide nanocrystal. X-ray diffraction analysis indicates the formation of tetragonal rutile phase structure for all the samples. The crystallite size was estimated from the HRTEM images and it is around 6–12 nm. Using optical absorbance measurement, the band gap energy value of the samples has been calculated. It reveals the existence of quantum confinement effect in all the prepared samples. Photoluminescence (PL) spectra confirms that the luminescence process originates from the structural defects such as oxygen vacancies present in the samples. Room temperature hysteresis loop was clearly observed in M–H curve of all the samples. But the sol–gel derived sample shows the higher values of saturation magnetization (M{sub s}) and remanence (M{sub r}) than other two samples. This study reveals that the sol–gel method is superior to the other two methods for producing room temperature ferromagnetism in tin oxide nanocrystal.

  1. Survey of licensee control room habitability practices

    International Nuclear Information System (INIS)

    Boland, J.F.; Brookshire, R.L.; Danielson, W.F.; Driscoll, J.W.; Graham, E.D.; McConnell, R.J.; Thompson, V.N.

    1985-04-01

    This document presents the results of a survey of Licensee control-room-habitability practices. The survey is part of a comprehensive program plan instituted in August 1983 by the NRC to respond to ongoing questions from the Advisory Committee on Reactor Safeguards (ACRS). The emphasis of this survey was to determine by field review the control-room habitability practices at three different plants, one of which is still under construction and scheduled to receive an operating license in 1986. The other two plants are currently operating, having received operating licenses in the mid-1970's and early 1980's. The major finding of this survey is that despite the fact that the latest control-room-habitability systems have become larger and more complex than earlier systems surveyed, the latest systems do not appear to be functionally superior. The major recommendation of this report is to consolidate into a single NRC document, based upon a comprehensive systems engineering approach, the pertinent criteria for control-room-habitability design

  2. Vibrometer based on a self-mixing effect interferometer

    International Nuclear Information System (INIS)

    Marti-Lopez, Luis; Gonzalez-Penna, R.; Martinez-Celorio, R. A.

    2009-01-01

    We outline the basic principles of the self-mixing effect and present the design and construction of an interferometer based on this phenomenon. It differs from the previously reported in the literature by the use of two photodetectors, located at different arms of the interferometer. This feature allows widening the arsenal of strategies for the digital processing of the signal. The interferometer is used as vibrometer for the characterization of professional loudspeakers. Experimental results are presented as an illustration. (Author)

  3. Fission-Product Separation Based on Room-Temperature Ionic Liquids. Final Report

    International Nuclear Information System (INIS)

    Hussey, Charles L.

    2008-01-01

    During previous DOE sponsored research (DE-FG07-01ER63286), a process was developed for removing Cs+ and Sr2+ from simulated aqueous tank waste by extraction of these ions into a hydrophobic room-temperature ionic liquid solvent, tri-n-butylmethylammonium bis((trifluoromethyl)sulfonyl)imide, containing the ionophores, calix(4)arene-bis(tert-octylbenzo-crown-6) and dicyclohexano-18-crown-6. The coordinated Cs+ and Sr2+ could be removed from the ionic liquid extraction solvent by an electrochemical reduction process carried out at mercury electrodes. In this follow-up project, the effects of residual moisture and oxygen on this processing scheme were assessed. It was determined that the electrochemical reduction of ionophore-bound Cs+ at Hg electrodes is surprisingly tolerant of small amounts of water, but greatly affected by oxygen. However, sparging of the ionic liquid with dry N2 lowers the residual water and oxygen content of the extraction solvent to the level where the reduction of Cs+ at Hg is possible. Thus, the entire treatment cycle for the removal of Cs+ from tank waste using this approach can be carried out in an open cell, provided that the cell is continuously sparged with dry N2. (Due to a reduction in the funds designated for the project, it was not possible to investigate the effects of moisture and oxygen on the Sr2+ removal process.) Additional research carried out under this project led to the discovery and characterization of a new low-melting urea-based melt that can be used as an electrochemical solvent. This melt is less expensive to prepare than most of the well-know room-temperature ionic liquid solvents, has a better electrochemical window than existing urea-based melts, and has potential applications for the processing of nuclear waste. This melt is made by combining urea with the N,N-dialkylimidazolium salt, 1-ethyl-3-methylimidazolium chloride.

  4. Shielding design of a treatment room for an accelerator-based epithermal neutron irradiation facility for BNCT

    International Nuclear Information System (INIS)

    Evans, J.F.; Blue, T.E.

    1996-01-01

    Protecting the facility personnel and the general public from radiation exposure is a primary safety concern of an accelerator-based epithermal neutron irradiation facility. This work makes an attempt at answering the questions open-quotes How much?close quotes and open-quotes What kind?close quotes of shielding will meet the occupational limits of such a facility. Shielding effectiveness is compared for ordinary and barytes concretes in combination with and without borated polyethylene. A calculational model was developed of a treatment room, patient open-quotes scatterer,close quotes and the epithermal neutron beam. The Monte Carlo code, MCNP, was used to compute the total effective dose equivalent rates at specific points of interest outside of the treatment room. A conservative occupational effective dose rate limit of 0.01 mSv h -1 was the guideline for this study. Conservative Monte Carlo calculations show that constructing the treatment room walls with 1.5 m of ordinary concrete, 1.2 m of barytes concrete, 1.0 m of ordinary concrete preceded by 10 cm of 5% boron-polyethylene, or 0.8 m of barytes concrete preceded by 10 cm of 5% boron-polyethylene will adequately protect facility personnel. 20 refs., 8 figs., 2 tabs

  5. Room-temperature ductile inorganic semiconductor

    Science.gov (United States)

    Shi, Xun; Chen, Hongyi; Hao, Feng; Liu, Ruiheng; Wang, Tuo; Qiu, Pengfei; Burkhardt, Ulrich; Grin, Yuri; Chen, Lidong

    2018-05-01

    Ductility is common in metals and metal-based alloys, but is rarely observed in inorganic semiconductors and ceramic insulators. In particular, room-temperature ductile inorganic semiconductors were not known until now. Here, we report an inorganic α-Ag2S semiconductor that exhibits extraordinary metal-like ductility with high plastic deformation strains at room temperature. Analysis of the chemical bonding reveals systems of planes with relatively weak atomic interactions in the crystal structure. In combination with irregularly distributed silver-silver and sulfur-silver bonds due to the silver diffusion, they suppress the cleavage of the material, and thus result in unprecedented ductility. This work opens up the possibility of searching for ductile inorganic semiconductors/ceramics for flexible electronic devices.

  6. Limitations of temperature measurement in the aural canal with an ear mould integrated sensor

    International Nuclear Information System (INIS)

    Teunissen, L P J; Daanen, H A M; De Haan, A; De Koning, J J; Clairbois, H E

    2011-01-01

    Aural canal temperature measurement using an ear mould integrated sensor (T ac ) might be a method suited for continuous non-invasive core temperature estimation in operational settings. We studied the effect of ambient temperature, wind and high intensity exercise on T ac and its ability to predict esophageal (T es ) and rectal temperatures (T re ). Seven subjects performed a protocol of rest at 21, 10 and 30 °C, followed by exercise and recovery at 30 °C. The subjects performed the protocol twice: with and without face-wind from halfway through the 30 °C rest period. Extra auricle insulation was applied at one side. Ambient temperature changes affected T ac significantly, while T es and T re remained stable. Insulating the auricle reduced but did not abolish this effect. Wind had an immediate cooling effect on T ac independent of auricle insulation. During exercise and recovery in 30 °C, T ac provided acceptable group predictions of T re in trials without wind (bias: −0.66 ± 0.21 °C covered, −1.20 ± 0.15 °C uncovered). Bias was considerably higher with wind, but variability was similar (−1.73 ± 0.11 °C covered, −2.49 ± 0.04 °C uncovered). Individual predictions of T es and T re showed more variation, especially with wind. We conclude that T ac may be used for core temperature assessment of groups in warm and stable conditions

  7. Room Temperature Hard Radiation Detectors Based on Solid State Compound Semiconductors: An Overview

    Science.gov (United States)

    Mirzaei, Ali; Huh, Jeung-Soo; Kim, Sang Sub; Kim, Hyoun Woo

    2018-05-01

    Si and Ge single crystals are the most common semiconductor radiation detectors. However, they need to work at cryogenic temperatures to decrease their noise levels. In contrast, compound semiconductors can be operated at room temperature due to their ability to grow compound materials with tunable densities, band gaps and atomic numbers. Highly efficient room temperature hard radiation detectors can be utilized in biomedical diagnostics, nuclear safety and homeland security applications. In this review, we discuss room temperature compound semiconductors. Since the field of radiation detection is broad and a discussion of all compound materials for radiation sensing is impossible, we discuss the most important materials for the detection of hard radiation with a focus on binary heavy metal semiconductors and ternary and quaternary chalcogenide compounds.

  8. Room Temperature Hard Radiation Detectors Based on Solid State Compound Semiconductors: An Overview

    Science.gov (United States)

    Mirzaei, Ali; Huh, Jeung-Soo; Kim, Sang Sub; Kim, Hyoun Woo

    2018-03-01

    Si and Ge single crystals are the most common semiconductor radiation detectors. However, they need to work at cryogenic temperatures to decrease their noise levels. In contrast, compound semiconductors can be operated at room temperature due to their ability to grow compound materials with tunable densities, band gaps and atomic numbers. Highly efficient room temperature hard radiation detectors can be utilized in biomedical diagnostics, nuclear safety and homeland security applications. In this review, we discuss room temperature compound semiconductors. Since the field of radiation detection is broad and a discussion of all compound materials for radiation sensing is impossible, we discuss the most important materials for the detection of hard radiation with a focus on binary heavy metal semiconductors and ternary and quaternary chalcogenide compounds.

  9. Cyclic plastic response of nickel-based superalloy at room and at elevated temperatures

    International Nuclear Information System (INIS)

    Polak, Jaroslav; Petrenec, Martin; Chlupova, Alice; Tobias, Jiri; Petras, Roman

    2015-01-01

    Nickel-based cast IN 738LC superalloy has been cycled at increasing strain amplitudes at room temperature and at 800 C. Hysteresis loops were analyzed using general statistical theory of the hysteresis loop. Dislocation structures of specimens cycled at these two temperatures were studied. They revealed localization of the cyclic plastic strain in the thin bands which are rich in dislocations. The analysis of the loop shapes yields effective stresses of the matrix and of the precipitates and the probability density function of the critical internal stresses at both temperatures. It allows to find the sources of the high cyclic stress.

  10. New technologies for control room habitability assessment

    International Nuclear Information System (INIS)

    Lahti, G.P.; Muraida, J.E.; Perchiazzi, W.T.; Harden, P.A.

    1994-01-01

    Older nuclear power plants typically considered only a nominal amount of unfiltered inleakage (typically 10 cfm) impacting their postaccident control room habitability. However, recent measurements of unfiltered inleakage show values in excess of the nominal 10 cfm. A reassessment for two of these ''older'' stations has been completed recently to show that the measured inleakage did not jeopardize the safety of the control room occupants. Recent concerns at the Zion Station and the Palisades Station about control room habitability in the event of a loss-of-coolant accident have led to an extensive effort to increase control room habitability margin. The heating, ventilating and air-conditioning (HVAC) system servicing each of the control rooms has the potential for unfiltered in-leakage through many locations. For example, at the Palisades Station, the current limiting control room habitability analysis allows for 25 cfm unfiltered in-leakage through its normal outside air intake louvered isolation dampers during emergency mode into the control room envelope. This leakage value was not thought to be achievable with the existing as-built configuration. Repairing the system was considered a potential solution; however, this would be costly and could negatively affect plant operation. In addition, the system would still be required to meet the low specified unfiltered in-leakage. An alternate approach was to review the analysis and reassess the most important parameters. The key effort was to determine the atmospheric dispersion factors (χ/Qs) through wind tunnel tests using scale models of the stations. The results of the wind tunnel testing could yield more realistic χ/Qs for control room habitability than previously employed methods. The wind tunnel study options were selected based on their ease of implementation, realistic results, and low cost. More importantly, the results of the studies would allow more realistic values of unfiltered inleakage

  11. New insights into designing metallacarborane based room temperature hydrogen storage media.

    Science.gov (United States)

    Bora, Pankaj Lochan; Singh, Abhishek K

    2013-10-28

    Metallacarboranes are promising towards realizing room temperature hydrogen storage media because of the presence of both transition metal and carbon atoms. In metallacarborane clusters, the transition metal adsorbs hydrogen molecules and carbon can link these clusters to form metal organic framework, which can serve as a complete storage medium. Using first principles density functional calculations, we chalk out the underlying principles of designing an efficient metallacarborane based hydrogen storage media. The storage capacity of hydrogen depends upon the number of available transition metal d-orbitals, number of carbons, and dopant atoms in the cluster. These factors control the amount of charge transfer from metal to the cluster, thereby affecting the number of adsorbed hydrogen molecules. This correlation between the charge transfer and storage capacity is general in nature, and can be applied to designing efficient hydrogen storage systems. Following this strategy, a search for the best metallacarborane was carried out in which Sc based monocarborane was found to be the most promising H2 sorbent material with a 9 wt.% of reversible storage at ambient pressure and temperature.

  12. Parametric Room Acoustic Workflows

    DEFF Research Database (Denmark)

    Parigi, Dario; Svidt, Kjeld; Molin, Erik

    2017-01-01

    The paper investigates and assesses different room acoustics software and the opportunities they offer to engage in parametric acoustics workflow and to influence architectural designs. The first step consists in the testing and benchmarking of different tools on the basis of accuracy, speed...... and interoperability with Grasshopper 3d. The focus will be placed to the benchmarking of three different acoustic analysis tools based on raytracing. To compare the accuracy and speed of the acoustic evaluation across different tools, a homogeneous set of acoustic parameters is chosen. The room acoustics parameters...... included in the set are reverberation time (EDT, RT30), clarity (C50), loudness (G), and definition (D50). Scenarios are discussed for determining at different design stages the most suitable acoustic tool. Those scenarios are characterized, by the use of less accurate but fast evaluation tools to be used...

  13. Real-time adaptive concepts in acoustics blind signal separation and multichannel echo cancellation

    CERN Document Server

    Schobben, Daniel W E

    2001-01-01

    Blind Signal Separation (BSS) deals with recovering (filtered versions of) source signals from an observed mixture thereof. The term `blind' relates to the fact that there are no reference signals for the source signals and also that the mixing system is unknown. This book presents a new method for blind signal separation, which is developed to work on microphone signals. Acoustic Echo Cancellation (AEC) is a well-known technique to suppress the echo that a microphone picks up from a loudspeaker in the same room. Such acoustic feedback occurs for example in hands-free telephony and can lead to a perceived loud tone. For an application such as a voice-controlled television, a stereo AEC is required to suppress the contribution of the stereo loudspeaker setup. A generalized AEC is presented that is suited for multi-channel operation. New algorithms for Blind Signal Separation and multi-channel Acoustic Echo Cancellation are presented. A background is given in array signal processing methods, adaptive filter the...

  14. Control room MMI 2000 for NORS simulator in HAMMLAB

    International Nuclear Information System (INIS)

    Saarni, R.; Foerdestroemmen, N.T.; Meyer, B.D.; Skjerve, A.B.M.

    2001-03-01

    The report presents the control room MMI as of year 2000 for the NORS simulator in HAMMLAB. It consists of two main parts: NORS Reference Control Room MMI and NORS Experimental Control Room MMI. They are both utilised in human factors experiments in HAMMLAB. The HAMMLAB Experimental Control Room 2000 is presented together with the NORS Reference CR MMI, which includes the following display types: Overview displays, process and control displays, trend displays, supplementary alarm displays and logic displays for the protection system and other automatic control systems. User experiences based on feedback from professional Loviisa NPP operators are also given. For the Experimental Control Room MMI, main emphasis is on presenting the design of a new large screen overview display called; experimental Automatic Information Presentation (AIP) display. It was used for the first time last year in the HCA-2000 experiment in HAMMLAB. The design is quite different from previous overview displays being developed and used in HAMMLAB. The display presents the overall dynamic status of both the process and the automatic systems. The plans for the future include to develop and user test an upgraded AIP overview display, and to enhance and user test a limited set of task-based display prototypes. (Author)

  15. Future control room design (modernization of control room systems)

    International Nuclear Information System (INIS)

    Reischl, Ludwig; Freitag, Timo; Dergel, Rene

    2009-01-01

    In the frame of lifetime extension for nuclear power plants the modernization of the complete safety and operational control technology will be digitalized. It is also recommended to modernize the operator facilities, monitoring systems in the control room, the back-up shut-down center and the local control stations. The authors summarize the reasons for the modernization recommendations and discuss possible solutions for display-oriented control rooms. A concept for control room backfitting includes generic requirements, requirements of the local authorities, ergonomic principles information content and information density, and the design process. The backfitting strategy should include a cooperation with the operational personnel, The quality assurance and training via simulator needs sufficient timing during the implementation of the backfitting.

  16. Human-system interface evaluation system for advanced control room based on SQL database

    International Nuclear Information System (INIS)

    Zhang Yan; Zhou Zhiwei; Bian Zhiqiang; Xu Li

    2005-01-01

    User Interface (UI) plays an important role in the advanced control room (ACR) of a nuclear power plant (NPP). In this paper, we present a rule-based ACR Human-system Interface Evaluation System (AHSIES) using expert system technology, which can evaluate UI design shortcomings, propose modification suggestions, and help designer improve the ACR interface design. AHSIES consists of four programs: the UI Editor, the Operation Procedure Manager, the Operation Simulator and the UI Design Evaluator. These four parts respectively function for: editing a set of UI icons employed as the operation screens of an advanced control room; for editing operation procedures aiming at any specified operation with simple language; for simulate the operation sequences dynamically and recording the relevant information for design performance of the UIs; and for evaluating both static and dynamic performance of the ACR UI design according to well established design guidelines and criteria with the information gained from the first three programs. Microsoft SQL Server 2000 DBMS is adopted to manage the voluminous data and its complex relationships. The preliminary test application of AHSIES for a simplified ACR UI design of a PWR NPP has shown that the expert evaluation system is capable of achieving satisfactory evaluation results. (authors)

  17. Controlling the clean room atmosphere

    International Nuclear Information System (INIS)

    Meeks, R.F.

    1979-01-01

    Several types of clean rooms are commonly in use. They include the conventional clean room, the horizontal laminar flow clean room, the vertical laminar flow clean room and a fourth type that incorporates ideas from the previous types and is known as a clean air bench or hood. These clean rooms are briefly described. The origin of contamination and methods for controlling the contamination are discussed

  18. Control room habitability study: findings and recommendations

    International Nuclear Information System (INIS)

    Driscoll, J.W.

    1986-01-01

    The Advisory Committee on Reactor Safeguards (ACRS) has raised a number of concerns related to control room habitability and has recommended actions which they believe could alleviate these concerns. As a result of the ACRS's concerns, the US Nuclear Regulatory Commission's (NRC) Office of Nuclear Reactor Regulation (NRR) in conjunction with the Offices of Research and Inspection and Enforcement, and the NRC regional offices, embarked upon a program to reevaluate Control Room Habitability. Argonne National Laboratory was contracted by the NRC to perform a Control Room Habitability Study on twelve licensed power reactors. The plants selected for the study were chosen based upon architect engineer, nuclear steam system supplier, utility, and plant location. Participants in the study review the plant design as contained in the Updated Safety Analysis Report, Technical Specifications, Three Mile Island action item III.D.3.4 submittal on Control Room Habitability, NRC staff evaluation of the III.D.3.4 submittal, appropriate plant operating procedures, system drawings, and significant Licensee Event Reports on Loss of Cooling to the Control Room Envelope. A two-day visit is then made to the plant to determine if the as-built systems are built, operated, and surveillance performed as described in the documentation reviewed prior to the visit. The major findings of this study are included in this report along with generic recommendations of the review team that apply to control room HVAC systems. Although the study is not complete, at the time of publication of this report, the results obtained to date should be useful to persons responsible for Control Room Habitability in evaluating their own systems

  19. Functionalized Ga2O3 nanowires as active material in room temperature capacitance-based gas sensors.

    Science.gov (United States)

    Mazeina, Lena; Perkins, F Keith; Bermudez, Victor M; Arnold, Stephen P; Prokes, S M

    2010-08-17

    We report the first evidence for functionalization of Ga(2)O(3) nanowires (NWs), which have been incorporated as the active material in room temperature capacitance gas-sensing devices. An adsorbed layer of pyruvic acid (PA) was successfully formed on Ga(2)O(3) NWs by simple room temperature vapor transport, which was confirmed by Fourier transform infrared spectroscopy. The effect of the adsorbed PA on the surface properties was demonstrated by the change in the response of the NW gas-sensing devices. Results indicate that the adsorption of PA reduced the sensitivity of the Ga(2)O(3) NW device to common hydrocarbons such as nitromethane and acetone while improving the response to triethylamine by an order of magnitude. Taking into account the simplicity of this functionalization together with the ease of producing these capacitance-based gas-sensing devices, this approach represents a viable technique for sensor development.

  20. Control room lay-out

    International Nuclear Information System (INIS)

    Toma, Violeta

    2004-01-01

    TRIUMF (Tri-University Meson Facility) is Canada's national laboratory for particle and nuclear physics. There are 6 accelerators and 3 Control Rooms at TRIUMF. The main control room serves the big cyclotron, the 500 MeV, and the adjacent experiment. The 42 MeV and two 32 MeV ones are production dedicated. These cyclotrons belong to a private company but are operated by TRIUMF staff from ATG (Applied Technology Group) Control Room. The last is ISAC (Isotope Acceleration and Separation) Control Room, from which the LINAC is controlled. Research areas cover theoretical (2 subjects), pure (5 subjects) and applied (8 subjects) physics. In the early '70s, as the 500 MeV was being completed, the first Control Room was built in the main accelerator building. The recent topics covered by this paper are proton and pion therapy, what are the operator's duties?, the CP42, TR30 and TR13 cyclotron control rooms, the ISAC control systems including control room modification. Due to the nature of an operator's job, the Control Room layout is pretty important. This is true for any work environment, but when working shifts it becomes essential. Lots of time and effort, not to mention money, were spent to figure out the optimum configuration. It seems to me that the key factor in the control room layout is versatility, and this is because it has to keep happy a group of people with different inclinations, which have a tendency to become quite moody after the second night shift. No matter what, there will still be unhappy people, but we are trying our best. (Y. Tanaka)

  1. Decontamination of the activation product based on a legal revision of the cyclotron vault room on the non-self-shield compact medical cyclotron

    International Nuclear Information System (INIS)

    Komiya, Isao; Umezu, Yoshiyuki; Fujibuchi, Toshiou; Nakamura, Kazumasa; Baba, Shingo; Honda, Hiroshi

    2016-01-01

    The non-self-shield compact medical cyclotron and the cyclotron vault room were in operation for 27 years. They have now been decommissioned. We efficiently implemented a technique to identify an activation product in the cyclotron vault room. Firstly, the distribution of radioactive concentrations in the concrete of the cyclotron vault room was estimated by calculation from the record of the cyclotron operation. Secondly, the comparison of calculated results with an actual measurement was performed using a NaI scintillation survey meter and a high-purity germanium detector. The calculated values were overestimated as compared to the values measured using the Nal scintillation survey meter and the high-purity germanium detector. However, it could limit the decontamination area. By simulating the activation range, we were able to minimize the concrete core sampling. Finally, the appropriate range of radioactivated area in the cyclotron vault room was decontaminated based on the results of the calculation. After decontamination, the radioactive concentration was below the detection limit value in all areas inside the cyclotron vault room. By these procedures, the decommissioning process of the cyclotron vault room was more efficiently performed. (author)

  2. Room-temperature antiferromagnetic memory resistor.

    Science.gov (United States)

    Marti, X; Fina, I; Frontera, C; Liu, Jian; Wadley, P; He, Q; Paull, R J; Clarkson, J D; Kudrnovský, J; Turek, I; Kuneš, J; Yi, D; Chu, J-H; Nelson, C T; You, L; Arenholz, E; Salahuddin, S; Fontcuberta, J; Jungwirth, T; Ramesh, R

    2014-04-01

    The bistability of ordered spin states in ferromagnets provides the basis for magnetic memory functionality. The latest generation of magnetic random access memories rely on an efficient approach in which magnetic fields are replaced by electrical means for writing and reading the information in ferromagnets. This concept may eventually reduce the sensitivity of ferromagnets to magnetic field perturbations to being a weakness for data retention and the ferromagnetic stray fields to an obstacle for high-density memory integration. Here we report a room-temperature bistable antiferromagnetic (AFM) memory that produces negligible stray fields and is insensitive to strong magnetic fields. We use a resistor made of a FeRh AFM, which orders ferromagnetically roughly 100 K above room temperature, and therefore allows us to set different collective directions for the Fe moments by applied magnetic field. On cooling to room temperature, AFM order sets in with the direction of the AFM moments predetermined by the field and moment direction in the high-temperature ferromagnetic state. For electrical reading, we use an AFM analogue of the anisotropic magnetoresistance. Our microscopic theory modelling confirms that this archetypical spintronic effect, discovered more than 150 years ago in ferromagnets, is also present in AFMs. Our work demonstrates the feasibility of fabricating room-temperature spintronic memories with AFMs, which in turn expands the base of available magnetic materials for devices with properties that cannot be achieved with ferromagnets.

  3. Multi-bed patient room architectural evaluation

    Directory of Open Access Journals (Sweden)

    Evangelia Sklavou

    2016-12-01

    Full Text Available Introduction: Leveraging the physical environment’s merits is crucial in healthcare settings towards fostering sustainable healing conditions. In the future, the need to retrofit hospitals already appears more probable than to build new facilities. In Greece, holistic healthcare architecture has significant potential and room to develop. Aim: The architectural research of multi-bed patient room environment. Method: A sample of multi-bed patient rooms of a Greek hospital was studied per architectural documentation and user evaluation survey. Beyond recording the existing situation and user experience, user group differences and the influence of window proximity were studied. The survey sample was based on convenience and comprised 160 patients and 136 visitors. Statistical analysis was performed in SPSS 20, using chi-square exact tests of independence. The chosen level of significance was p < 0.05. Results: Architectural documentation showed that the building morphology had a positive impact in patient rooms, with regard to sunlight penetration and view. Further solar daylight control was deemed necessary, to facilitate overall environmental comfort conditions. High spatial density and considerable disadvantages of the middle patient bed, compared to the one bedside the window and the one further in the back of the room, were also ascertained. User groups did not evaluate their surroundings significantly different, with the exception of ease of access to the view. Window proximity influenced both patients and visitors in evaluating ease of access to the view and visual discomfort. Patients were further affected on window size evaluation and visitors on view related aspects. Conclusions: Synergy between building form and function contributes in creating holistic sustainable healing environments. User evaluation can deviate from objective documentation. Patients and visitors experienced the patient room in a similar manner. The middle bed was

  4. Room Acoustical Fields

    CERN Document Server

    Mechel, Fridolin

    2013-01-01

    This book presents the theory of room acoustical fields and revises the Mirror Source Methods for practical computational use, emphasizing the wave character of acoustical fields.  The presented higher methods include the concepts of “Mirror Point Sources” and “Corner sources which allow for an excellent approximation of complex room geometries and even equipped rooms. In contrast to classical description, this book extends the theory of sound fields describing them by their complex sound pressure and the particle velocity. This approach enables accurate descriptions of interference and absorption phenomena.

  5. Video Conferencing for a Virtual Seminar Room

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Fosgerau, A.; Hansen, Peter Søren K.

    2002-01-01

    A PC-based video conferencing system for a virtual seminar room is presented. The platform is enhanced with DSPs for audio and video coding and processing. A microphone array is used to facilitate audio based speaker tracking, which is used for adaptive beam-forming and automatic camera...

  6. Have it your way. A modular approach to custom compact control rooms

    International Nuclear Information System (INIS)

    Harmon, Daryl; Scarola, Ken

    2003-01-01

    In spite of the recent lack of growth in the nuclear power industry, a transition is taking place to compact main control rooms as the design of choice for power generating facilities. This is evident in the design and construction of new facilities, including Advanced Light Water Reactors such as the Korean Shin Kori 3 and 4 units, as well as Generation IV reactors. Also, compact control rooms are increasingly preferred for the modernization of current generation plants. This shift reflects that compact control rooms combine cost savings through equipment reduction and standardization with operability improvements through increased functionality and flexibility and improved presentation. Though compact control rooms feature significantly fewer Human Machine Interface (HMI) devices than their conventional counterparts, customers still require a wide variety of different configurations to accommodate their individual operations philosophies, cultural norms, licensing regulations and physical constraints. To meet this need, Westinghouse Electric Company has developed an innovative, modular approach to designing compact control rooms for nuclear power plants. This approach features a small set of standard HMI devices serving as building blocks for all compact control room functions. The building blocks include qualified and non-safety video devices for implementing displays, alarms, multi-channel soft controls, computerized procedures, etc. These building blocks can be used for (1) large screen overview displays, (2) console-based control and monitoring and (3) HMI devices for conventional, benchboard-style control panels. Their modular design allows these building blocks to be arranged in various physical configurations to meet a wide variety of customer's control room preferences and constraints. For example, a compact control room could use the qualified building blocks (1) to configure a dedicated safety panel independent of the normal operational consoles, or (2

  7. Control room habitability assessment and in-leakage test for Korean NPP - 15510

    International Nuclear Information System (INIS)

    Song, D.S.; Lee, J.B.; Ha, S.J.; Seong, J.J.

    2015-01-01

    The assessment of control room habitability for Wolsung unit 1 was performed based on GL 2003-01 and Reg. Guide 1.197. The control room habitability program including Control Room Envelope (CRE) in-leakage test procedures, self assessment guidance, CRE boundary control program, CRE maintenance/sealing program was developed for Wolsung unit 1. The integrated CRE test was performed utilizing ASTM E741. There are two operating modes of pressurization and isolation for CRE ventilation test, and four tests were performed using each of the control room HVAC sub-trains. The control room HVAC system lineup of pressurization mode test was based upon a lineup that encompassed the design basis radiological analyses. The other control room HVAC system lineup of isolation mode test was based on an operation mode that considers toxic gas. The in-leakage testing was performed in accordance with CRE in-leakage test procedures. In the pressurization mode, measured unfiltered in-leakage rates for train A and train B were 0 CFM and 405 CFM respectively. In the isolation mode, measured unfiltered in-leakage rates for train A and train B were 1,739 CFM and 1,502 CFM, respectively. Maximum concentration of ammonia at the control room HVAC intake is calculated to be 0.027 g/m 3 (39 ppm), and satisfied the toxicity limit of 300 ppm. The test result shows that the measured unfiltered in-leakage is bounded by the regulatory criteria assumed in the design basis radiological analyses. (authors)

  8. Nuclear power plant control room ventilation system design for meeting general criterion 19

    International Nuclear Information System (INIS)

    Murphy, K.G.; Campe, K.M.

    1975-01-01

    The requirement for protection of control room personnel against radiation is specified in General Design Criterion 19 of Appendix A, 10 CFR Part 50. The evaluation of a control room design, especially its emergency ventilation system, with respect to radiation protection primarily consists of determining the radiation doses to control room personnel under accident conditions. The accident dose assessment involves modeling and evaluation of radiological source terms, atmospheric transport of airborne activity, and protection features of the control room ventilation system. Some of the assumptions and conservatisms used in the dose analyses are based on the technical review experience of existing or proposed control room designs. A review of over 50 control room designs has revealed a great variety of design concepts, not all of which seem to have been based on radiation protection criteria. A summary of the basic control room protection requirements, design features, dose acceptance criteria, and an outline of the methods used by the Regulatory staff for accident dose evaluation are presented. (U.S.)

  9. The measure and control system of mini-type radon room based on PC104

    International Nuclear Information System (INIS)

    Zhou Shumin; East China Inst. of Technology, Fuzhou; Tang Bin; Sun Yamin

    2005-01-01

    Radon room is one of the standard equipment which demarcates radon measure instrument. The paper discusses the dynamic method and mathematic model which keeps the radon consistence stability in radon room. The system is developed on PC104. The system can monitor the radon consistence and replenishment radon according the radon control parameter. (authors)

  10. Use of task analysis in control room evaluations

    International Nuclear Information System (INIS)

    Ross, K.C.

    1981-01-01

    Responding to recently formulated regulatory requirements, the BWR Owners' Group, working in conjunction with General Electric, has formulated a method for performing human factors design reviews of nuclear power plant control rooms. This process incorporates task analyses to analyze operational aspects of panel layout and design. Correlation of operator functions defined by emergency procedures against required controls and displays has proven successful in identifying instrumentation required in the control room to adequately respond to transient conditions, and in evaluating the effectiveness of panel design and physical arrangement. Extensions of the analysis have provided information on operator response paths, frequency of use of instruments, and control room layout. The techniques used were based on a need to identify primary controls and indications required by the operator in performing each step of the applicable procedure. The relative locations of these instruments were then analyzed for information on the adequacy of the control room design for those conditions

  11. Multimode marine engine room simulation system based on field bus technology

    Science.gov (United States)

    Zheng, Huayao; Deng, Linlin; Guo, Yi

    2003-09-01

    Developing multi mode MER (Marine Engine Room) Labs is the main work in Marine Simulation Center, which is the key lab of Communication Ministry of China. It includes FPP (Fixed Pitch Propeller) and CPP (Controllable Pitch Propeller) mode MER simulation systems, integrated electrical propulsion mode MER simulation system, physical mode MER lab, etc. FPP mode simulation system, which was oriented to large container ship, had been completed since 1999, and got second level of Shanghai Municipal Science and Technical Progress award. This paper mainly introduces the recent development and achievements of Marine Simulation Center. Based on the Lon Works field bus, the structure characteristics and control strategies of completely distributed intelligent control network are discussed. The experiment mode of multi-nodes field bus detection and control system is described. Besides, intelligent fault diagnosis technology about some mechatronics integration control systems explored is also involved.

  12. Room temperature large self-biased magnetoelectric effect in non-lead based piezoelectric and magnetostrictive (0−3) particulate composite system

    International Nuclear Information System (INIS)

    Kumari, Mukesh; Prakash, Chandra; Chatterjee, Ratnamala

    2017-01-01

    In this work, room temperature magnetoelectric properties of (0−3) particulate composites of non lead based piezoelectric BNTKNNLTS [0.97(Bi 0.5 Na 0.5 TiO 3 )–0.03(K 0.47 Na 0.47 Li 0.06 Nb 0.74 Sb 0.06 Ta 0.2 O 3 ) and magnetostrictive CZFMO (Co 0.6 Zn 0.4 Fe 1.7 Mn 0.3 O 4 ) are presented. Composite samples of (1-x)(BNTKNNLTS)-x(CZFMO) , with x=0.1 and 0.5, are synthesized by solid state reaction route. X-ray diffraction confirms the single phase formation of parent phases and the presence of two phases in the composites. Similar sintering conditions of the two individual components lead to optimal ferroelectric and ferromagnetic properties in the composites. A large self-biased magnetoelectric (ME) coupling ~74 mV/cm.Oe for the sample with x=0.1 (measured in longitudinally magnetized-transversely polarized configuration) is observed at room temperature. - Highlights: • Modified BNT-CFO based (0−3) particulate composites have been synthesized. • Similar sintering conditions of two components lead to optimal multiferroicity. • A large self-biased ME coupling ~74 mV/cm. Oe is obtained at room temperature.

  13. The development of KNGR control room man-machine interface design

    International Nuclear Information System (INIS)

    Sung-Jae Cho; Yeong-Cheol Shin

    2000-01-01

    KNGR MMI design has been developed for the last 7 years as a part of Korea Next Generation Reactor (KNGR) design development. The KNGR control room has the common features of advanced control room such as large display panel, redundant compact workstations, soft control, and computerized procedure system. A conventional type safety console is provided as a backup when operation at the workstations is impossible. The strong points of an advanced control room are based on the powerful information processing and flexible graphic presentation capability of computer technology. On the other hand, workstation based design has a weak point that the amount of information to be presented in one VDU is limited. This can cause navigational overload and inconsistent interfaces and provide chances for performance errors/failures, if not designed carefully. From this background, the regulators require licensees to follow strict top-down human factor engineering design process. Analysis of operating experiences and iterative evaluations are used to address the potential problems of the KNGR advanced control room MMI design. But, further study is necessary in design area like CPS design, where experiences or design guidance is insufficient. Further study topics for KNGR advanced control room MMI design development are discussed briefly in this paper. (author)

  14. Diversity of anaerobic microbes in spacecraft assembly clean rooms.

    Science.gov (United States)

    Probst, Alexander; Vaishampayan, Parag; Osman, Shariff; Moissl-Eichinger, Christine; Andersen, Gary L; Venkateswaran, Kasthuri

    2010-05-01

    Although the cultivable and noncultivable microbial diversity of spacecraft assembly clean rooms has been previously documented using conventional and state-of-the-art molecular techniques, the occurrence of obligate anaerobes within these clean rooms is still uncertain. Therefore, anaerobic bacterial communities of three clean-room facilities were analyzed during assembly of the Mars Science Laboratory rover. Anaerobic bacteria were cultured on several media, and DNA was extracted from suitable anaerobic enrichments and examined with conventional 16S rRNA gene clone library, as well as high-density phylogenetic 16S rRNA gene microarray (PhyloChip) technologies. The culture-dependent analyses predominantly showed the presence of clostridial and propionibacterial strains. The 16S rRNA gene sequences retrieved from clone libraries revealed distinct microbial populations associated with each clean-room facility, clustered exclusively within gram-positive organisms. PhyloChip analysis detected a greater microbial diversity, spanning many phyla of bacteria, and provided a deeper insight into the microbial community structure of the clean-room facilities. This study presents an integrated approach for assessing the anaerobic microbial population within clean-room facilities, using both molecular and cultivation-based analyses. The results reveal that highly diverse anaerobic bacterial populations persist in the clean rooms even after the imposition of rigorous maintenance programs and will pose a challenge to planetary protection implementation activities.

  15. Guidelines for control room design reviews

    International Nuclear Information System (INIS)

    1981-09-01

    The control room design review is part of a broad program being undertaken by the nuclear industry and the government to ensure consideration of human factors in nuclear power plant design and operation. The purpose of the control room design review described by these guidelines is to (1) review and evaluate the control room workspace, instrumentation, controls, and other equipment from a human factors engineering point of view that takes into account both system demands and operator capabilities; and (2) to identify, assess, and implement control room design modifications that correct inadequate or unsuitable items. The scope of the control room design review described by these guidelines covers the human engineering review of completed control rooms; i.e., operational control rooms or those at that stage of the licensing process where control room design and equipment selection are committed. These guidelines should also be of use during the design process for new control rooms. However, additional analyses to optimize the allocation of functions to man and machine, and further examination of advanced control system technology, are recommended for new control rooms. Guidelines and references for comprehensive system analyses designed to incorporate human factors considerations into the design and development of new control rooms are presented in Appendix B. Where possible, a generic approach to the control room design review process is encouraged; for example, when control room designs are replicated wholly or in part in two or more units. Even when designs are not replicated exactly, generic reviews which can be modified to account for specific differences in particular control rooms should be considered. Industry organizations and owners groups are encouraged to coordinate joint efforts and share data to develop generic approaches to the design review process. The control room design review should accomplish the following specific objectives. To determine

  16. Regenerator-based thermoacoustic refrigerator for ice cream storage applications

    Science.gov (United States)

    Poese, Matthew E.; Smith, Robert W. M.; Garrett, Steven L.

    2003-10-01

    A regenerator-based chiller has been built in the ``bellows bounce'' style [J. Acoust. Soc. Am. 112, 15 (2002)] to replace the vapor compression system in an ice cream sales cabinet. It utilizes a 6-in.-diam metal bellows to form a compliant cavity that contains the dynamic pressure oscillation (>50 kPa). The stiffness of the gas trapped in the bellows is resonated against the mass of the bellows-cap and the mass of a moving-magnet linear motor which is capable of high (>85%) electro-acoustic efficiency. A second resonator, operated well below its natural frequency, uses the gas stiffness of a 1-l volume nested within the bellows and the inertia of an ordinary loudspeaker cone to create the pressure difference across the regenerator that drives gas flow that is in-phase with pressure. The mass of the cone can be adjusted to vary the multiplication factor that is typically 5%-10% greater than the dynamic pressure within the bellows. The loudspeaker cone suffers none of the hydrodynamic losses associated with an acoustic inertance and eliminates problems with dc gas flow in the energy feedback path. The cold heat exchanger forms one surface of the pressure vessel permitting direct contact with any thermal load. [Work supported by Ben and Jerry's Homemade.

  17. Analysis of the operator's tasks: An aid to control room design

    International Nuclear Information System (INIS)

    Blanc, P.; Guesnier, G.P.; Heilbronn, B.; Monnier, B.

    1983-01-01

    The control room designer usually has no knowledge of the tasks performed by the operator in the control room since an overall picture of the situation only becomes available once the whole facility has been constructed. In order to study and design control rooms for its future PWR units, Electricite de France (EDF) felt it was essential to analyse these tasks: the work was facilitated by the existence of 900 MW PWR units which were already in operation and which are controlled in much the same manner as future units of the same type. Accordingly, by analysing the control procedures of these 900 MW PWR units, a data base describing the control and monitoring tasks performed by operators in normal, incident and accident situations has been built up. The data-base files, which were established from a study of 130 control procedures, record all the commands given and data available in the control room (about 7000), describe the tasks connected with these commands and data, and identify the times at which they are made use of by the operator. Using this data base, the principle of operator-system communication and of data processing in the control room of the future has been established: in such a control room, most controls and data will be accessible through computer communication systems to ensure that control and monitoring systems are closely integrated under normal operating conditions as well as in incident and post-accident situations and to enable the plant to be controlled by one or two operators in a seated position. (author)

  18. FRAMEWORK AND APPLICATION FOR MODELING CONTROL ROOM CREW PERFORMANCE AT NUCLEAR POWER PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L Boring; David I Gertman; Tuan Q Tran; Brian F Gore

    2008-09-01

    This paper summarizes an emerging project regarding the utilization of high-fidelity MIDAS simulations for visualizing and modeling control room crew performance at nuclear power plants. The key envisioned uses for MIDAS-based control room simulations are: (i) the estimation of human error associated with advanced control room equipment and configurations, (ii) the investigative determination of contributory cognitive factors for risk significant scenarios involving control room operating crews, and (iii) the certification of reduced staffing levels in advanced control rooms. It is proposed that MIDAS serves as a key component for the effective modeling of cognition, elements of situation awareness, and risk associated with human performance in next generation control rooms.

  19. FRAMEWORK AND APPLICATION FOR MODELING CONTROL ROOM CREW PERFORMANCE AT NUCLEAR POWER PLANTS

    International Nuclear Information System (INIS)

    Ronald L Boring; David I Gertman; Tuan Q Tran; Brian F Gore

    2008-01-01

    This paper summarizes an emerging project regarding the utilization of high-fidelity MIDAS simulations for visualizing and modeling control room crew performance at nuclear power plants. The key envisioned uses for MIDAS-based control room simulations are: (1) the estimation of human error associated with advanced control room equipment and configurations, (2) the investigative determination of contributory cognitive factors for risk significant scenarios involving control room operating crews, and (3) the certification of reduced staffing levels in advanced control rooms. It is proposed that MIDAS serves as a key component for the effective modeling of cognition, elements of situation awareness, and risk associated with human performance in next generation control rooms

  20. Broadcast sound technology

    CERN Document Server

    Talbot-Smith, Michael

    1990-01-01

    Broadcast Sound Technology provides an explanation of the underlying principles of modern audio technology. Organized into 21 chapters, the book first describes the basic sound; behavior of sound waves; aspects of hearing, harming, and charming the ear; room acoustics; reverberation; microphones; phantom power; loudspeakers; basic stereo; and monitoring of audio signal. Subsequent chapters explore the processing of audio signal, sockets, sound desks, and digital audio. Analogue and digital tape recording and reproduction, as well as noise reduction, are also explained.

  1. Airflow and Temperature Distribution in Rooms with Displacement Ventilation

    DEFF Research Database (Denmark)

    Jacobsen, T. V.

    This thesis deals with air flow and temperature distribution in a room ventilated by the displacement principle. The characteristic features of the ventilation system are treated in the whole room but main emphasis is laid on the analysis of the stratified flow region in front of the inlet device....... After a prefatory description of the background and the fundamentals of displacement ventilation the objectives of the current study are specified. The subsequent sections describe the measurements of velocity and temperature profiles carried out in a full scale test room. Based on experimental data...... of measured data is of crucial importance. Qualitatively satisfactory results do not ensure quantitative agreement....

  2. Tunable, Room Temperature THZ Emitters Based on Nonlinear Photonics

    Science.gov (United States)

    Sinha, Raju

    The Terahertz (1012 Hz) region of the electromagnetic spectrum covers the frequency range from roughly 300 GHz to 10 THz, which is in between the microwave and infrared regimes. The increasing interest in the development of ultra-compact, tunable room temperature Terahertz (THz) emitters with wide-range tunability has stimulated in-depth studies of different mechanisms of THz generation in the past decade due to its various potential applications such as biomedical diagnosis, security screening, chemical identification, life sciences and very high speed wireless communication. Despite the tremendous research and development efforts, all the available state-of-the-art THz emitters suffer from either being large, complex and costly, or operating at low temperatures, lacking tunability, having a very short spectral range and a low output power. Hence, the major objective of this research was to develop simple, inexpensive, compact, room temperature THz sources with wide-range tunability. We investigated THz radiation in a hybrid optical and THz micro-ring resonators system. For the first time, we were able to satisfy the DFG phase matching condition for the above-mentioned THz range in one single device geometry by employing a modal phase matching technique and using two separately designed resonators capable of oscillating at input optical waves and generated THz waves. In chapter 6, we proposed a novel plasmonic antenna geometry – the dimer rod-tapered antenna (DRTA), where we created a hot-spot in the nanogap between the dimer arms with a very large intensity enhancement of 4.1x105 at optical resonant wavelength. Then, we investigated DFG operation in the antenna geometry by incorporating a nonlinear nanodot in the hot-spot of the antenna and achieved continuously tunable enhanced THz radiation across 0.5-10 THz range. In chapter 8, we designed a multi-metallic resonators providing an ultrasharp toroidal response at THz frequency, then fabricated and

  3. Control room design and human engineering in power plants

    International Nuclear Information System (INIS)

    Herbst, L.; Hinz, W.

    1982-01-01

    The concept for modern plant control rooms is primary influenced by: The automation of protection, binary control and closed loop control functions; organization employing functional areas; computer based information processing; human engineered design. Automation reduces the human work load. Employment of functional areas permits optimization of operational sequences. Computer based information processing makes it possible to output information in accordance with operating requirements. Design based on human engineering principles assures the quality of the interaction between the operator and the equipment. The degree to which these conceptional features play a role in design of power plant control rooms depends on the unit rating, the mode of operation and on the requirements respecting safety and availability of the plant. (orig.)

  4. Room temperature CO and H2 sensing with carbon nanoparticles

    International Nuclear Information System (INIS)

    Kim, Daegyu; Pikhitsa, Peter V; Yang, Hongjoo; Choi, Mansoo

    2011-01-01

    We report on a shell-shaped carbon nanoparticle (SCNP)-based gas sensor that reversibly detects reducing gas molecules such as CO and H 2 at room temperature both in air and inert atmosphere. Crystalline SCNPs were synthesized by laser-assisted reactions in pure acetylene gas flow, chemically treated to obtain well-dispersed SCNPs and then patterned on a substrate by the ion-induced focusing method. Our chemically functionalized SCNP-based gas sensor works for low concentrations of CO and H 2 at room temperature even without Pd or Pt catalysts commonly used for splitting H 2 molecules into reactive H atoms, while metal oxide gas sensors and bare carbon-nanotube-based gas sensors for sensing CO and H 2 molecules can operate only at elevated temperatures. A pristine SCNP-based gas sensor was also examined to prove the role of functional groups formed on the surface of functionalized SCNPs. A pristine SCNP gas sensor showed no response to reducing gases at room temperature but a significant response at elevated temperature, indicating a different sensing mechanism from a chemically functionalized SCNP sensor.

  5. Room for both qualification and inclusion?

    DEFF Research Database (Denmark)

    Ringskou, Lea Thomsen; Gravesen, David Thore

    2017-01-01

    Our research project concerns the work of leisure time pedagogues in the Danish primary school, more precisely the rooms and roles they practice in and construct. A reform in 2014 invited the pedagogues into a series of new activities and curriculum based school activities. Activities dominated...

  6. CSN's New Emergency Room

    International Nuclear Information System (INIS)

    Sendin, P.

    2005-01-01

    During the month of July 2005 the physical renovation works and technological updating of the basic infrastructures of the CSN Emergency Room (SALEM) were finished, allowing the Room to now have greater functionality and a broader technical capacity. Nevertheless, the technological improvement process of SALEM will reach its full potential within the next few years, once the installation currently underway of the new information integration and monitoring systems and the decision making support systems have been completed. This article describes the improvements introduced to the Room and the objectives pursued in this renovation project to convert the SALEM into a new generation room in accordance with its current technological context. (Author) 4 refs

  7. Room Temperature Co-Precipitation Synthesis of Magnetite Nanoparticles in a Large pH Window with Different Bases.

    Science.gov (United States)

    Mascolo, Maria Cristina; Pei, Yongbing; Ring, Terry A

    2013-11-28

    Magnetite nanoparticles (Fe₃O₄) represent the most promising materials in medical applications. To favor high-drug or enzyme loading on the nanoparticles, they are incorporated into mesoporous materials to form a hybrid support with the consequent reduction of magnetization saturation. The direct synthesis of mesoporous structures appears to be of interest. To this end, magnetite nanoparticles have been synthesized using a one pot co-precipitation reaction at room temperature in the presence of different bases, such as NaOH, KOH or (C₂H₅)₄NOH. Magnetite shows characteristics of superparamagnetism at room temperature and a saturation magnetization (Ms) value depending on both the crystal size and the degree of agglomeration of individual nanoparticles. Such agglomeration appears to be responsible for the formation of mesoporous structures, which are affected by the pH, the nature of alkali, the slow or fast addition of alkaline solution and the drying modality of synthesized powders.

  8. A Fiber Bragg grating based tilt sensor suitable for constant temperature room

    International Nuclear Information System (INIS)

    Tang, Guoyu; Wei, Jue; Zhou, Wei; Wu, Mingyu; Yang, Meichao; Xie, Ruijun; Xu, Xiaofeng

    2015-01-01

    Constant-temperature rooms have been widely used in industrial production, quality testing, and research laboratories. This paper proposes a high-precision tilt sensor suitable for a constant- temperature room, which has achieved a wide-range power change while the fiber Bragg grating (FBG) reflection peak wavelength shifted very little, thereby demonstrating a novel method for obtaining a high-precision tilt sensor. This paper also studies the effect of the reflection peak on measurement precision. The proposed sensor can distinguish the direction of tilt with an excellent sensitivity of 403 dBm/° and a highest achievable resolution of 2.481 × 10 −5 ° (that is, 0.08% of the measuring range). (paper)

  9. Clinical Education Environment Experiences of Operating Room Students

    Directory of Open Access Journals (Sweden)

    Tahereh khazaei

    2016-01-01

    Full Text Available Background and purpose: The objective of medical education is to train competent and qualified workforce in order to provide services in various health environments. One of the important objectives of Operating Room students is to train workforce who can involve in patient’s health and recovery. Training these students should cause clinical ability and independent decision making during surgery. Since students during internship face with many problems, this study has been conducted to explore and describe the challenges and experiences.Methods: This qualitative study is a phenomenology that was conducted based on 20 students in the last semester of Operating Room associate’s degree with purposive sampling. Deep and semi-structured interviews were used to collect data and data were analyzed by content analysis method.Results: The findings in 5 main themes: (1 Physical space and equipment in the operating room, (2 The student’s position in operating room, (3 Integrating knowledge and action, (4 Managing education environment and 5- Student’s viewpoint about operating room and working in it.Conclusions: Interviews with students revealed the educational environment challenges with which they are faced during their study. Teachers can provide solutions to overcome the challenges and create a positive atmosphere for students' learning using results of this study and students may continue their interest in education and improve the quality of their education.Keywords: CLINICAL EDUCATION, OPERATING ROOM STUDENTS, CHALLENGE

  10. Simultaneousness of room heating and ventilation air heating

    International Nuclear Information System (INIS)

    Mathisen, Hans Martin

    2006-01-01

    The report is part of NTNU-SINTEF's Smart Buildings program, Smart Energy Efficient Buildings (2002-2006), subprogram 3.1 Heating, ventilation and cooling systems. An important part of this subprogram is the development and implementation of heating distribution systems with low return temperature. A comparison has been made of the simultaneousness of room heating and ventilation air heating in six buildings. Existing measuring data with hourly measurements of effect requirements for the different purposes have been employed. Based on the measuring data the relation between the requirements for room heating and ventilation is estimated. A 'fictitious' return temperature has also been estimated. The result shows a significant variation between the buildings. For all there are short periods where the efficiency need for room heating and ventilation is equal (ml)

  11. Human factors design review guidelines for advanced nuclear control room technologies

    International Nuclear Information System (INIS)

    O'Hara, J.; Brown, W.; Granda, T.; Baker, C.

    1991-01-01

    Advanced control rooms (ACRs) for future nuclear power plants are being designed utilizing computer-based technologies. The US Nuclear Regulatory Commission reviews the human engineering aspects of such control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported in order to protect public health and safety. This paper describes the rationale, general approach, and initial development of an NRC Advanced Control Room Design Review Guideline. 20 refs., 1 fig

  12. Control room envelope unfiltered air inleakage test protocols

    International Nuclear Information System (INIS)

    Lagus, P.L.; Grot, R.A.

    1997-01-01

    In 1983, the Advisory Committee on Reactor Safeguards (ACRS) recommended that the US NRC develop a control room HVAC performance testing protocol. To date no such protocol has been forthcoming. Beginning in mid-1994, an effort was funded by NRC under a Small Business Innovation Research (SBIR) grant to develop several simplified test protocols based on the principles of tracer gas testing in order to measure the total unfiltered inleakage entering a CRE during emergency mode operation of the control room ventilation system. These would allow accurate assessment of unfiltered air inleakage as required in SRP 6.4. The continuing lack of a standard protocol is unfortunate since one of the significant parameters required to calculate operator dose is the amount of unfiltered air inleakage into the control room. Often it is assumed that, if the Control Room Envelope (CRE) is maintained at +1/8 in. w.g. differential pressure relative to the surroundings, no significant unfiltered inleakage can occur it is further assumed that inleakage due to door openings is the only source of unfiltered air. 23 refs., 13 figs., 2 tabs

  13. Control room envelope unfiltered air inleakage test protocols

    Energy Technology Data Exchange (ETDEWEB)

    Lagus, P.L. [Lagus Applied Technology, San Diego, CA (United States); Grot, R.A. [Lagus Applied Technology, Olney, MD (United States)

    1997-08-01

    In 1983, the Advisory Committee on Reactor Safeguards (ACRS) recommended that the US NRC develop a control room HVAC performance testing protocol. To date no such protocol has been forthcoming. Beginning in mid-1994, an effort was funded by NRC under a Small Business Innovation Research (SBIR) grant to develop several simplified test protocols based on the principles of tracer gas testing in order to measure the total unfiltered inleakage entering a CRE during emergency mode operation of the control room ventilation system. These would allow accurate assessment of unfiltered air inleakage as required in SRP 6.4. The continuing lack of a standard protocol is unfortunate since one of the significant parameters required to calculate operator dose is the amount of unfiltered air inleakage into the control room. Often it is assumed that, if the Control Room Envelope (CRE) is maintained at +1/8 in. w.g. differential pressure relative to the surroundings, no significant unfiltered inleakage can occur it is further assumed that inleakage due to door openings is the only source of unfiltered air. 23 refs., 13 figs., 2 tabs.

  14. Personal Exposure Between People in a Room Ventilated by Textile Terminals

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Hyldgård, Carl-Erik; Melikov, Arsen

    2007-01-01

    This paper describes an investigation made in a room ventilated by an air distribution system based on a textile terminal. The air distribution in the room is mainly controlled by buoyancy forces from the heat sources, although the flow from the textile terminal can be characterized as a displace...

  15. ARDressCode: Augmented Dressing Room with Tag-based Motion Tracking and Real-Time Clothes Simulation

    DEFF Research Database (Denmark)

    Kjærside, Krista; Kortbek, Karen Johanne; Møller, Henrik Hedegaard

    2005-01-01

    This paper introduces a new augmented reality concept for dressing rooms enabling a customer to combine a tactile experience of the fabrics with easy simulated try-on. The dressing room has a camera and a projection surface instead of a mirror. The customers stick a few visual tags to their normal...

  16. Large magneto-conductance and magneto-electroluminescence in exciplex-based organic light-emitting diodes at room temperature

    Science.gov (United States)

    Ling, Yongzhou; Lei, Yanlian; Zhang, Qiaoming; Chen, Lixiang; Song, Qunliang; Xiong, Zuhong

    2015-11-01

    In this work, we report on large magneto-conductance (MC) over 60% and magneto-electroluminescence (MEL) as high as 112% at room temperature in an exciplex-based organic light-emitting diode (OLED) with efficient reverse intersystem crossing (ISC). The large MC and MEL are individually confirmed by the current density-voltage characteristics and the electroluminescence spectra under various magnetic fields. We proposed that this type of magnetic field effect (MFE) is governed by the field-modulated reverse ISC between the singlet and triplet exciplex. The temperature-dependent MFEs reveal that the small activation energy of reverse ISC accounts for the large MFEs in the present exciplex-based OLEDs.

  17. Testing of Method for Assessing of Room Thermal Stability

    Directory of Open Access Journals (Sweden)

    Charvátová Hana

    2017-01-01

    Full Text Available The paper presents the interim results of our research on the developing methodological procedure which could be used for assessment of a thermal stability of buildings with regards to its thermal accumulative parameters. The principle of testing is based on a combination of computer simulation of cooled room model developed in COMSOL Multiphysics software and on theoretical calculations with respect to compliance with valid European and Czech technical standards used in building industry and architecture under conditions obtained by real measurement for the room to be tested. The presented example shows the effect of the heataccumulation properties of the outside wall insulation materials on the course of the cooling room for winter conditions.

  18. A new sensor for ammonia based on cyanidin-sensitized titanium dioxide film operating at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Xiao-wei, Huang [School of Food and Biological Engineering, Jiangsu University, 301 Xuefu Road, 212013 Zhenjiang, Jiangsu (China); Xiao-bo, Zou, E-mail: zou_xiaobo@ujs.edu.cn [School of Food and Biological Engineering, Jiangsu University, 301 Xuefu Road, 212013 Zhenjiang, Jiangsu (China); Key Laboratory of Modern Agricultural Equipment and Technology, 301 Xuefu Road, 212013 Zhenjiang, Jiangsu (China); Ji-yong, Shi; Jie-wen, Zhao; Yanxiao, Li [School of Food and Biological Engineering, Jiangsu University, 301 Xuefu Road, 212013 Zhenjiang, Jiangsu (China); Limin, Hao; Jianchun, Zhang [The Research Center of China Hemp Materials, Beijing (China)

    2013-07-17

    Graphical abstract: -- Highlights: •TiO{sub 2} was prepared by sol–gel method film and then functionalized with the cyanidin dye. •The morphology and the absorption spectra of films were examined. •The hybrid organic–inorganic formed film here can detect ammonia reversibly at room temperature. •The low humidity could promote the sensitivity of the sensors. -- Abstract: Design and fabrication of an ammonia sensor operating at room temperature based on pigment-sensitized TiO{sub 2} films was described. TiO{sub 2} was prepared by sol–gel method and deposited on glass slides containing gold electrodes. Then, the film immersed in a 2.5 × 10{sup −4} M ethanol solution of cyanidin to absorb the pigment. The hybrid organic–inorganic formed film here can detect ammonia reversibly at room temperature. The relative change resistance of the films at a potential difference of 1.5 V is determined when the films are exposed to atmospheres containing ammonia vapors with concentrations over the range 10–50 ppm. The relative change resistance, S, of the films increased almost linearly with increasing concentrations of ammonia (r = 0.92). The response time to increasing concentrations of the ammonia is about 180–220 s, and the corresponding values for decreasing concentrations 240–270 s. At low humidity, ammonia could be ionized by the cyanidin on the TiO{sub 2} film and thereby decrease in the proton concentration at the surface. Consequently, more positively charged holes at the surface of the TiO{sub 2} have to be extracted to neutralize the adsorbed cyanidin and water film. The resistance response to ammonia of the sensors was nearly independent on temperature from 10 to 50 °C. These results are not actually as good as those reported in the literature, but this preliminary work proposes simpler and cheaper processes to realize NH{sub 3} sensor for room temperature applications.

  19. Visual-auditory integration for visual search: a behavioral study in barn owls

    Directory of Open Access Journals (Sweden)

    Yael eHazan

    2015-02-01

    Full Text Available Barn owls are nocturnal predators that rely on both vision and hearing for survival. The optic tectum of barn owls, a midbrain structure involved in selective attention, has been used as a model for studying visual- auditory integration at the neuronal level. However, behavioral data on visual- auditory integration in barn owls are lacking. The goal of this study was to examine if the integration of visual and auditory signals contributes to the process of guiding attention towards salient stimuli. We attached miniature wireless video cameras on barn owls' heads (OwlCam to track their target of gaze. We first provide evidence that the area centralis (a retinal area with a maximal density of photoreceptors is used as a functional fovea in barn owls. Thus, by mapping the projection of the area centralis on the OwlCam's video frame, it is possible to extract the target of gaze. For the experiment, owls were positioned on a high perch and four food items were scattered in a large arena on the floor. In addition, a hidden loudspeaker was positioned in the arena. The positions of the food items and speaker were changed every session. Video sequences from the OwlCam were saved for offline analysis while the owls spontaneously scanned the room and the food items with abrupt gaze shifts (head saccades. From time to time during the experiment, a brief sound was emitted from the speaker. The fixation points immediately following the sounds were extracted and the distances between the gaze position and the nearest items and loudspeaker were measured. The head saccades were rarely towards the location of the sound source but to salient visual features in the room, such as the door knob or the food items. However, among the food items, the one closest to the loudspeaker had the highest probability of attracting a gaze shift. This result supports the notion that auditory signals are integrated with visual information for the selection of the next visual search

  20. Emergency control room design of a nuclear reactor used to produce radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Isaac J.A.L. dos; Farias, Larissa P. de; Ponte, Luana T.L.; Goncalves, Gabriel L.; Castro, Heraclito M.; Farias, Marcos S.; Carvalho, Paulo V.R. de; Vianna Filho, Alfredo M.V., E-mail: luquetti@ien.gov.br [Instituto Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Departamento Engenharia Nuclear

    2015-07-01

    A control room is defined as a functional entity with an associated physical structure, where the operators carry out the centralized control, monitoring and administrative responsibilities. Emergency control room acts as an alternative control room for the purpose of shutting down or maintaining the facility in a safe shutdown state when the main control room is uninhabitable. The mission of emergency control room is to provide the resources to bring the plant to a safe shutdown condition after an evacuation of the main control room. An evacuation of the main control room is assumed when there is no possibility to accomplish tasks involved in the shutdown except reactor trip. The purpose of this paper is to present a specific approach for the design of the emergency control room of a nuclear reactor used to produce radioisotope. The approach is based on human factors standards and the participation of a multidisciplinary team in the development phase of the design. Using the information gathered from standards and from the multidisciplinary team a 3D Sketch and a 3D printing of the emergency control room were created. (author)

  1. Emergency control room design of a nuclear reactor used to produce radioisotope

    International Nuclear Information System (INIS)

    Santos, Isaac J.A.L. dos; Farias, Larissa P. de; Ponte, Luana T.L.; Goncalves, Gabriel L.; Castro, Heraclito M.; Farias, Marcos S.; Carvalho, Paulo V.R. de; Vianna Filho, Alfredo M.V.

    2015-01-01

    A control room is defined as a functional entity with an associated physical structure, where the operators carry out the centralized control, monitoring and administrative responsibilities. Emergency control room acts as an alternative control room for the purpose of shutting down or maintaining the facility in a safe shutdown state when the main control room is uninhabitable. The mission of emergency control room is to provide the resources to bring the plant to a safe shutdown condition after an evacuation of the main control room. An evacuation of the main control room is assumed when there is no possibility to accomplish tasks involved in the shutdown except reactor trip. The purpose of this paper is to present a specific approach for the design of the emergency control room of a nuclear reactor used to produce radioisotope. The approach is based on human factors standards and the participation of a multidisciplinary team in the development phase of the design. Using the information gathered from standards and from the multidisciplinary team a 3D Sketch and a 3D printing of the emergency control room were created. (author)

  2. Room temperature large self-biased magnetoelectric effect in non-lead based piezoelectric and magnetostrictive (0−3) particulate composite system

    Energy Technology Data Exchange (ETDEWEB)

    Kumari, Mukesh [Magnetics & Advanced Ceramics Laboratory, Indian Institute of Technology, Delhi-110016 India (India); Prakash, Chandra [Solid State Physics Laboratory Timarpur, Delhi-110054 India (India); Chatterjee, Ratnamala, E-mail: rmala@physics.iitd.ac.in [Magnetics & Advanced Ceramics Laboratory, Indian Institute of Technology, Delhi-110016 India (India)

    2017-05-01

    In this work, room temperature magnetoelectric properties of (0−3) particulate composites of non lead based piezoelectric BNTKNNLTS [0.97(Bi{sub 0.5}Na{sub 0.5}TiO{sub 3})–0.03(K{sub 0.47}Na{sub 0.47}Li{sub 0.06}Nb{sub 0.74}Sb{sub 0.06}Ta{sub 0.2}O{sub 3}) and magnetostrictive CZFMO (Co{sub 0.6}Zn{sub 0.4}Fe{sub 1.7}Mn{sub 0.3}O{sub 4}) are presented. Composite samples of (1-x)(BNTKNNLTS)-x(CZFMO){sub ,} with x=0.1 and 0.5, are synthesized by solid state reaction route. X-ray diffraction confirms the single phase formation of parent phases and the presence of two phases in the composites. Similar sintering conditions of the two individual components lead to optimal ferroelectric and ferromagnetic properties in the composites. A large self-biased magnetoelectric (ME) coupling ~74 mV/cm.Oe for the sample with x=0.1 (measured in longitudinally magnetized-transversely polarized configuration) is observed at room temperature. - Highlights: • Modified BNT-CFO based (0−3) particulate composites have been synthesized. • Similar sintering conditions of two components lead to optimal multiferroicity. • A large self-biased ME coupling ~74 mV/cm. Oe is obtained at room temperature.

  3. Safety measures in exposure room

    International Nuclear Information System (INIS)

    Muhammad Jamal Md Isa

    2004-01-01

    The contents of this chapter are follows - The exposure room: location and dimension, material and thickness, windows, doors and other openings; Position of the Irradiating Apparatus, Use of Space Adjoining the Room, Warning Signs/Light, Dark Room. Materials and Apparatus: Classification of Areas, Local Rules, Other General Safety Requirements

  4. Fire protection for clean rooms

    International Nuclear Information System (INIS)

    Kirson, D.

    1990-01-01

    The fire protection engineer often must decide what size fire can be tolerated before automatic fire suppression systems actuate. Is it a wastepaper basket fire, a bushel basket fire...? In the case of state-of-the-art clean rooms, the answer clearly is not even an incipient fire. Minor fires in clean rooms can cause major losses. This paper discusses what a clean room is and gives a brief overview of the unique fire protection challenges encountered. The two major causes of fire related to clean rooms in the semiconductor industry are flammable/pyrophoric gas fires in plastic ducts and polypropylene wet bench fires. This paper concentrates on plastic ductwork in clean rooms, sprinkler protection in ductwork, and protection for wet benches

  5. Room Temperature Co-Precipitation Synthesis of Magnetite Nanoparticles in a Large pH Window with Different Bases

    Directory of Open Access Journals (Sweden)

    Maria Cristina Mascolo

    2013-11-01

    Full Text Available Magnetite nanoparticles (Fe3O4 represent the most promising materials in medical applications. To favor high-drug or enzyme loading on the nanoparticles, they are incorporated into mesoporous materials to form a hybrid support with the consequent reduction of magnetization saturation. The direct synthesis of mesoporous structures appears to be of interest. To this end, magnetite nanoparticles have been synthesized using a one pot co-precipitation reaction at room temperature in the presence of different bases, such as NaOH, KOH or (C2H54NOH. Magnetite shows characteristics of superparamagnetism at room temperature and a saturation magnetization (Ms value depending on both the crystal size and the degree of agglomeration of individual nanoparticles. Such agglomeration appears to be responsible for the formation of mesoporous structures, which are affected by the pH, the nature of alkali, the slow or fast addition of alkaline solution and the drying modality of synthesized powders.

  6. Room temperature synthesis of Ni-based alloy nanoparticles by radiolysis.

    Energy Technology Data Exchange (ETDEWEB)

    Nenoff, Tina Maria; Berry, Donald T.; Lu, Ping; Leung, Kevin; Provencio, Paula Polyak; Stumpf, Roland Rudolph; Huang, Jian Yu; Zhang, Zhenyuan

    2009-09-01

    Room temperature radiolysis, density functional theory, and various nanoscale characterization methods were used to synthesize and fully describe Ni-based alloy nanoparticles (NPs) that were synthesized at room temperature. These complementary methods provide a strong basis in understanding and describing metastable phase regimes of alloy NPs whose reaction formation is determined by kinetic rather than thermodynamic reaction processes. Four series of NPs, (Ag-Ni, Pd-Ni, Co-Ni, and W-Ni) were analyzed and characterized by a variety of methods, including UV-vis, TEM/HRTEM, HAADF-STEM and EFTEM mapping. In the first focus of research, AgNi and PdNi were studied. Different ratios of Ag{sub x}- Ni{sub 1-x} alloy NPs and Pd{sub 0.5}- Ni{sub 0.5} alloy NP were prepared using a high dose rate from gamma irradiation. Images from high-angle annular dark-field (HAADF) show that the Ag-Ni NPs are not core-shell structure but are homogeneous alloys in composition. Energy filtered transmission electron microscopy (EFTEM) maps show the homogeneity of the metals in each alloy NP. Of particular interest are the normally immiscible Ag-Ni NPs. All evidence confirmed that homogeneous Ag-Ni and Pd-Ni alloy NPs presented here were successfully synthesized by high dose rate radiolytic methodology. A mechanism is provided to explain the homogeneous formation of the alloy NPs. Furthermore, studies of Pd-Ni NPs by in situ TEM (with heated stage) shows the ability to sinter these NPs at temperatures below 800 C. In the second set of work, CoNi and WNi superalloy NPs were attempted at 50/50 concentration ratios using high dose rates from gamma irradiation. Preliminary results on synthesis and characterization have been completed and are presented. As with the earlier alloy NPs, no evidence of core-shell NP formation occurs. Microscopy results seem to indicate alloying occurred with the CoNi alloys. However, there appears to be incomplete reduction of the Na{sub 2}WO{sub 4} to form the W

  7. Room for caring

    DEFF Research Database (Denmark)

    Timmermann, Connie; Uhrenfeldt, Lisbeth; Birkelund, Regner

    2015-01-01

    Aim This study explores how seriously ill hospitalized patients' experience and assign meaning to their patient room. Background Modern hospitals and the rational underlying care and treatment of today have their emphasis on diagnosis, cure and treatment. Consequently, aesthetics in the patient...... rooms such as a view of nature or natural light entering the room are often neglected in caring for these patients. Method A phenomenological-hermeneutic study design was applied and data was collected through multiple qualitative interviews combined with observations at a teaching hospital in Denmark......-being, relief and hope for the patients during serious illness. Therefore, these sensory impressions should be thought of as holding palliative potential and should be included as a part of caring for the seriously ill patients....

  8. Control room design

    International Nuclear Information System (INIS)

    Zinke, H.

    1980-01-01

    To control a 1300 megawatt nuclear power plant, about 15000 plant parameters must be collected together to control and operate the plant. The control room design therefore is of particular importance. The main design criteria are: Required functions of the power plant process - Level of Automation - Ergonomics - Available Technology. Extensive analysis has resulted in a control room design method. This ensures that an objective solution will be reached. Resulting from this methodical approach are: 1. Scope, position and appearance of the instrumentation. 2. Scope, position and appearance of the operator controls. Process analysis dictates what instrumentation and operator controls are needed. The priority and importance of the control and instrumentation (this we define as the utilisation areas), dictates the rough layout of the control room. (orig./RW)

  9. Impact of healthcare design on patients' perception of a rheumatology outpatient infusion room

    DEFF Research Database (Denmark)

    Bukh, Gunhild; Tommerup, Anne Marie Munk; Madsen, Ole Rintek

    2015-01-01

    Evidence-based healthcare design is a concept aimed at reducing stress factors in the physical environment for the benefit of patients and the medical staff. The objective of this study was to examine the impact of room modifications on patients' perception of an outpatient infusion room used...... the potential to improve patients' perception of outpatient infusion rooms used for treating rheumatologic diseases....

  10. Evaluation of the shielding of a room for radiodiagnostic

    International Nuclear Information System (INIS)

    Padilla R, Z. P.; Acuna D, E.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    The X-ray discovery by Roentgen in 1895 and its application in diagnosis was a breakthrough in medicine. Worldwide, X-ray technique is one of the most widely used procedures in medical diagnosis. At the Mental Health Hospital of Calera Zacatecas a room has been designed as radiology room, however there is not a record of shielding characteristics. In order to determine the features of X-ray equipment that the room can host, in this work a series of calculations were carried out. Calculations were based upon the NCRP 151 recommendations and fulfilling the requirements given in the Mexican standard NOM-229-SSA1-2002. From the actual room conditions this can host a X-ray equipment without fluoroscopy, with a workload of 80 ma-min/week, with 125 k Vp as maximum operating voltage. From the actual conditions a set of recommendations, for better protection of radiation workers and public are also given. (Author)

  11. First installation of a dual-room IVR-CT system in the emergency room.

    Science.gov (United States)

    Wada, Daiki; Nakamori, Yasushi; Kanayama, Shuji; Maruyama, Shuhei; Kawada, Masahiro; Iwamura, Hiromu; Hayakawa, Koichi; Saito, Fukuki; Kuwagata, Yasuyuki

    2018-03-05

    Computed tomography (CT) embedded in the emergency room has gained importance in the early diagnostic phase of trauma care. In 2011, we implemented a new trauma workflow concept with a sliding CT scanner system with interventional radiology features (IVR-CT) that allows CT examination and emergency therapeutic intervention without relocating the patient, which we call the Hybrid emergency room (Hybrid ER). In the Hybrid ER, all life-saving procedures, CT examination, damage control surgery, and transcatheter arterial embolisation can be performed on the same table. Although the trauma workflow realized in the Hybrid ER may improve mortality in severe trauma, the Hybrid ER can potentially affect the efficacy of other in/outpatient diagnostic workflow because one room is occupied by one severely injured patient undergoing both emergency trauma care and CT scanning for long periods. In July 2017, we implemented a new trauma workflow concept with a dual-room sliding CT scanner system with interventional radiology features (dual-room IVR-CT) to increase patient throughput. When we perform emergency surgery or interventional radiology for a severely injured or ill patient in the Hybrid ER, the sliding CT scanner moves to the adjacent CT suite, and we can perform CT scanning of another in/outpatient. We believe that dual-room IVR-CT can contribute to the improvement of both the survival of severely injured or ill patients and patient throughput.

  12. Predicting the Room Air Temperature of the Containment Spray Pump Room for the Loss of HVAC Accidents

    International Nuclear Information System (INIS)

    Yoon, Churl; Park, Jin Hee; Lim, Ho Gon; Han, Sang Hoon

    2007-01-01

    In PSA Models, the HVAC system is essential for the various vital mitigation safety systems operating during a mission time. So far, the unavailability of the safety system when the HVAC system is unavailable, has been applied conservatively or optimistically based on operating experience and expert judgment, so the total core damage frequency could be unrealistic. In this paper, we performed a heat up calculation for the Containment Spray Pump Room at Kori 3 and 4 Units using a CFD code to estimate the operability of the CS pump and its support systems in the pump room under the situation of a loss of the HVAC. The result of this calculation could be applied the PSA Model for Risk Informed Regulation for Kori Units 3 and 4

  13. The Contaminant Distribution in a Ventilated Room with Different Air Terminal Devices

    DEFF Research Database (Denmark)

    Heiselberg, Per; Nielsen, Peter V.

    The room ventilation is investigated for three different air terminal devices under isothermal conditions. Velocity distribution in the occupied zone is measured for each air terminal device at different air exchange rates. The maximum air exchange rate is determined on the base of both the throw...... of the jets and the comfort requirements applied to measured air velocities in the occupied zone. Normalized concentration distribution in the test room is determined along a vertical line through the middle of the room as a function of the air exchange rate and the density of the tracer gas. The relative...... ventilation efficiency, , based on the room average concentration is also determined as a function of the air exchange rate and the density of the tracer gas. The influence from the position of the return opening on the relative ventilation efficiency is found for one air terminal device....

  14. Assessment of control room habitability and unfiltered air inleakage test of the OPR 1000 NPP

    International Nuclear Information System (INIS)

    Song, Dong Soo; Lee, Jong Beom; Ha, Sang Jun; Huh, Seong Cheol

    2015-01-01

    The assessment of control room habitability for Hanbit unit 5 was performed based on GL 2003-01 and Regulatory Guide 1.197. The integrated control room envelope (CRE) test was performed utilizing ASTM E741. Four tests were performed using each of the control room HVAC subtrains. The control room heating, ventilating, and air conditioning (HVAC) system lineup of pressurization mode test was based upon a lineup that encompassed the design basis radiological analyses. The other control room HVAC system lineup of isolation mode test was based on an operation mode that considers toxic gas. The measured inleakage for the isolation test mode remains within the toxicity limit. Radiation effect analysis showed that the measured inleakage satisfied the regulatory criteria, and the inleakage would not result in control room operator dose exceeding 50 mSv whole body and 500 mSv thyroid except train A pressurization test mode. The thyroid dose due to maximum measured unfiltered inleakage of 8976 lpm for train A is corresponding to 700 mSv. Modifications to the CRE boundary and control room HVAC system should be done to demonstrate that the measured unfiltered inleakage for train A pressurization test mode is bounded by the regulatory criteria assumed in the design basis radiological analyses. (author)

  15. Facial development of high performance room temperature NO2 gas sensors based on ZnO nanowalls decorated rGO nanosheets

    Science.gov (United States)

    Liu, Zongyuan; Yu, Lingmin; Guo, Fen; Liu, Sheng; Qi, Lijun; Shan, Minyu; Fan, Xinhui

    2017-11-01

    A highly sensitive NO2 gas sensor based on ZnO nanowalls decorated rGO nanosheets was fabricated using a thermal reduction and soft solution process. The highly developed interconnected microporous networks of ZnO nanowalls were anchored homogeneously on the surface of reduced graphene oxide (rGO). Sensors fabricated with heterojunction structures achieved a higher response (S = 9.61) and shorter response-recovery (25 s, 15 s) behavior at room temperature to 50 ppm level NO2 effectively in contrast to those sensors based on net ZnO nanowalls or rGO layers. The stability and selectivity of ZnO/rGO heterojunction were carried out. Meanwhile, the effects of humidity on ZnO/rGO heterojunction gas sensor were investigated. The more preferable sensing performance of ZnO/rGO heterojunction to NO2 was discussed. It can be surmised that this NO2 gas sensor has potential for use as a portable room temperature gas sensor.

  16. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft; Gao, Yi; Petersson, Eva

    2015-01-01

    This paper presents the design and evaluation of a usability and user experience test of a virtual dressing room. First, we motivate and introduce our recent developed prototype of a virtual dressing room. Next, we present the research and test design grounded in related usability and user...... experience studies. We give a description of the experimental setup and the execution of the designed usability and user experience test. To this end, we report interesting results and discuss the results with respect to user-centered design and development of a virtual dressing room....

  17. Evaluation of Sound Quality, Boominess and Boxiness in Small Rooms

    DEFF Research Database (Denmark)

    Weisser, Adam; Rindel, Jens Holger

    2006-01-01

    ratings. The classical bass ratio definitions showed poor correlation with all subjective ratings. The overall sound quality ratings gave different results for speech and music. For speech the preferred mean RT should be as low as possible, whereas for music there was found a preferred range between 0......The acoustics of small rooms has been studied with emphasis on sound quality, boominess and boxiness when the rooms are used for speech or music. Seven rooms with very different characteristics have been used for the study. Subjective listening tests were made using binaural recordings...... of reproduced speech and music. The test results were compared with a large number of objective acoustic parameters based on the frequency-dependent reverberation times measured in the rooms. This has led to the proposal of three new acoustic parameters, which have shown high correlation with the subjective...

  18. GOTHIC Simulation of APR1400 Auxiliary Charging Pump room heat up

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Hui-Un; Heo, Sun [KHNP, Daejeon (Korea, Republic of)

    2014-10-15

    As a part of the Advanced Power Reactor 1400 (APR1400) U. S. Nuclear Regulatory Commission Design Certification (NRC DC) project, we have been investigating Auxiliary Charging Pump (ACP) room heat up. With reference to the design specification of the ACP room, we determined input information and developed a GOTHIC model of the APR1400 ACP room. This calculation model is described herein, and representative results from the calculation are presented as well. The results of the present paper are used to determine the integrity of ACP operating in the accident. APR 1400 GOTHIC model was developed for ACP room heat up calculation. Calculation results confirm that door opening is cooling the room properly. It is found that the difference due to the surface option of heat conductors is insignificant. Based on this result, further studies should be performed to confirm integrity of ACP.

  19. The Influence of Room Colors in A House for Its Occupants

    Directory of Open Access Journals (Sweden)

    Dila Hendrassukma

    2016-01-01

    Full Text Available Home was a place where each individual could go after doing various routine activities. Residential interior design would support the quality of life of its occupants. The majority of the population of Indonesia, especially in Jakarta, had been aware of the importance of design interior of their homes properly. However, the selection of interior elements of color that was supporting the smoothness of the activities in a room was not considered as whole. The research objective was to analyze a great color for every room in the home based on the theory and the psychology of color. This article was expected to be a guide for those who will design an interior room. The method used was qualitative method in the form of observation and study of literature. Results of the study is the choice of a suitable color that fit in any room home, such as the living room, bedroom, kitchen, and bathroom can maximize the function of the room for the occupants. 

  20. Bulk heterojunction perovskite solar cells based on room temperature deposited hole-blocking layer: Suppressed hysteresis and flexible photovoltaic application

    Science.gov (United States)

    Chen, Zhiliang; Yang, Guang; Zheng, Xiaolu; Lei, Hongwei; Chen, Cong; Ma, Junjie; Wang, Hao; Fang, Guojia

    2017-05-01

    Perovskite solar cells have developed rapidly in recent years as the third generation solar cells. In spite of the great improvement achieved, there still exist some issues such as undesired hysteresis and indispensable high temperature process. In this work, bulk heterojunction perovskite-phenyl-C61-butyric acid methyl ester solar cells have been prepared to diminish hysteresis using a facile two step spin-coating method. Furthermore, high quality tin oxide films are fabricated using pulse laser deposition technique at room temperature without any annealing procedure. The as fabricated tin oxide film is successfully applied in bulk heterojunction perovskite solar cells as a hole blocking layer. Bulk heterojunction devices based on room temperature tin oxide exhibit almost hysteresis-free characteristics with power conversion efficiency of 17.29% and 14.0% on rigid and flexible substrates, respectively.

  1. Teaching and Learning of Aural and Oral Skills in Foreign Languages for Specific Purposes: The Preparation of Bilingual Hosts for the CONFINTEA VI

    Directory of Open Access Journals (Sweden)

    Edwiges Conceição de Souza Fernandes

    2013-12-01

    Full Text Available This paper focuses on a FLSP1 course where principles on the aural and oral development skills were addressed with the aim of preparing competent conference hosts to work for the CONFINTEA VI. The course takers were selected from two Public Brazilian Universities: The State University of Pará and The Federal University of Pará, by a process which involved previous needs assessment, course design, material selection and continuous collaborative teaching. Contextualized communicative strategies were used in order to facilitate interaction in the foreign languages with distinct groups of foreigners invited for the international event. The theoretical foundation of this paper lies principally on the works of Almeida Filho (1998, Dudley-Evans and St. John (1998, Hutchinson and Waters (1987, Munby (1978 and Nunan (1988. This teaching experience is reported through a qualitative perspective and its positive results were accredited to the effective learning environment created for the development of multicultural linguistic knowledge.

  2. Data for Room Fire Model Comparisons.

    Science.gov (United States)

    Peacock, Richard D; Davis, Sanford; Babrauskas, Vytenis

    1991-01-01

    With the development of models to predict fire growth and spread in buildings, there has been a concomitant evolution in the measurement and analysis of experimental data in real-scale fires. This report presents the types of analyses that can be used to examine large-scale room fire test data to prepare the data for comparison with zone-based fire models. Five sets of experimental data which can be used to test the limits of a typical two-zone fire model are detailed. A standard set of nomenclature describing the geometry of the building and the quantities measured in each experiment is presented. Availability of ancillary data (such as smaller-scale test results) is included. These descriptions, along with the data (available in computer-readable form) should allow comparisons between the experiment and model predictions. The base of experimental data ranges in complexity from one room tests with individual furniture items to a series of tests conducted in a multiple story hotel equipped with a zoned smoke control system.

  3. Data for Room Fire Model Comparisons

    Science.gov (United States)

    Peacock, Richard D.; Davis, Sanford; Babrauskas, Vytenis

    1991-01-01

    With the development of models to predict fire growth and spread in buildings, there has been a concomitant evolution in the measurement and analysis of experimental data in real-scale fires. This report presents the types of analyses that can be used to examine large-scale room fire test data to prepare the data for comparison with zone-based fire models. Five sets of experimental data which can be used to test the limits of a typical two-zone fire model are detailed. A standard set of nomenclature describing the geometry of the building and the quantities measured in each experiment is presented. Availability of ancillary data (such as smaller-scale test results) is included. These descriptions, along with the data (available in computer-readable form) should allow comparisons between the experiment and model predictions. The base of experimental data ranges in complexity from one room tests with individual furniture items to a series of tests conducted in a multiple story hotel equipped with a zoned smoke control system. PMID:28184121

  4. Control room design of a nuclear reactor used to produce radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Isaac Jose Antonio Luquetti dos; Carvalho, Paulo Vitor R.; Lacerda, Fabio de; Szabo, Andre P.; Vianna Filho, Alfredo Marques, E-mail: luquetti@ien.gov.br [Instituto Engenharia Nuclear (IEN/CNEN-RJ), Rio Janeiro, RJ (Brazil). Divisao de Instrumentacao e Confiabilidade Humana; Falcao, Mariana A. [Escola de Belas Artes da Universidade Federal do Rio de Janeiro, RJ (Brazil)

    2011-07-01

    A control room is defined as a functional entity with an associated physical structure, where the operators carry out the centralized control, monitoring and administrative responsibilities. Inadequate integration between control room and operators reduces safety, increases the operation complexity, complicates operator training and increases the likelihood of human errors occurrence. The purpose of this paper is to present a specific approach for the design of the main control room of a nuclear reactor used to produce radioisotope. The approach is based on human factors standards and the participation of a multidisciplinary team in the conceptual and basic phases of the design. Using the information gathered from standards and from the multidisciplinary an initial sketch 3D of the main control room is being developed. (author)

  5. Control room design of a nuclear reactor used to produce radioisotope

    International Nuclear Information System (INIS)

    Santos, Isaac Jose Antonio Luquetti dos; Carvalho, Paulo Vitor R.; Lacerda, Fabio de; Szabo, Andre P.; Vianna Filho, Alfredo Marques

    2011-01-01

    A control room is defined as a functional entity with an associated physical structure, where the operators carry out the centralized control, monitoring and administrative responsibilities. Inadequate integration between control room and operators reduces safety, increases the operation complexity, complicates operator training and increases the likelihood of human errors occurrence. The purpose of this paper is to present a specific approach for the design of the main control room of a nuclear reactor used to produce radioisotope. The approach is based on human factors standards and the participation of a multidisciplinary team in the conceptual and basic phases of the design. Using the information gathered from standards and from the multidisciplinary an initial sketch 3D of the main control room is being developed. (author)

  6. An electronic logbook for the HEP control room

    International Nuclear Information System (INIS)

    Roediger, G.; Pomatto, P.; Kyriakopulos, J.; Panacek, S.; Canal, P.; Kubarovsky, A.

    2001-01-01

    The Control Room Logbook (CRL) is designed to improve and replace the paper logbooks traditionally used in the HEP accelerator control room. Its features benefit the on-line coordinator, the shift operators, and the remote observers. The author explains some of the most attractive features for each of these roles. The features include the ability to configure the logbook for the specific needs of a collaboration, a large variety of entry types an operator can add by simply clicking and dragging, and a flexible web interface for the remote observer to keep up with control room activities. The entries and saved as UTF-8 based XML files, which allowed us to give the data structure and meaning such that it can easily be parsed in the present and far into the future. The XML tag data is also indexed in a relational database, making queries on dates, keywords, entry type and other criteria feasible and fast. The CRL is used in the D0 control room. This presentation also discusses our experience with deployment, platform independence and other interesting issues that arose with the installation and use of logbook

  7. An Electronic Logbook for the HEP Control Room

    International Nuclear Information System (INIS)

    Gary Roediger

    2001-01-01

    The Control Room Logbook (CRL) is designed to improve and replace the paper logbooks traditionally used in the HEP accelerator control room. Its features benefit the on-line coordinator, the shift operators, and the remote observers. This paper explains some of the most attractive features for each of these roles. The features include the ability to configure the logbook for the specific needs of a collaboration, a large variety of entry types an operator can add by simply clicking and dragging, and a flexible web interface for the remote observer to keep up with control room activities. The entries are saved as UTF-8 based XML files, which allowed us to give the data structure and meaning such that it can easily be parsed in the present and far into the future. The XML tag data is also indexed in a relational database, making queries on dates, keywords, entry type and other criteria feasible and fast. The CRL is used in the D0 control room. This presentation also discusses our experience with deployment, platform independence and other interesting issues that arose with the installation and use of the logbook

  8. Enhancement of NH3 gas sensitivity at room temperature by carbon nanotube-based sensor coated with Co nanoparticles.

    Science.gov (United States)

    Nguyen, Lich Quang; Phan, Pho Quoc; Duong, Huyen Ngoc; Nguyen, Chien Duc; Nguyen, Lam Huu

    2013-01-30

    Multi-walled carbon nanotube (MWCNT) film has been fabricated onto Pt-patterned alumina substrates using the chemical vapor deposition method for NH(3) gas sensing applications. The MWCNT-based sensor is sensitive to NH(3) gas at room temperature. Nanoclusters of Co catalysts have been sputtered on the surface of the MWCNT film to enhance gas sensitivity with respect to unfunctionalized CNT films. The gas sensitivity of Co-functionalized MWCNT-based gas sensors is thus significantly improved. The sensor exhibits good repeatability and high selectivity towards NH(3), compared with alcohol and LPG.

  9. Assessment of operating room air distribution in a mobile hospital: field experiment based on VDI 2167

    NARCIS (Netherlands)

    Forejt, L.; Drkal, F.; Hensen, J.L.M.; Seppänen, O.; Säteri, J.

    2007-01-01

    Air distribution in mobile operating room was assessed according to the recent acceptance test (VDI, 2004 [1]). This standard presents a simple and uniform validation procedure of operating room air distribution systems. Therefore it was applied as an objective method for evaluating performance of

  10. Highly sensitive and selective room-temperature NO_2 gas sensor based on bilayer transferred chemical vapor deposited graphene

    International Nuclear Information System (INIS)

    Seekaew, Yotsarayuth; Phokharatkul, Ditsayut; Wisitsoraat, Anurat; Wongchoosuk, Chatchawal

    2017-01-01

    Highlights: • Simple and low-cost fabrication of bilayer graphene gas sensor was presented. • Layer effects of graphene on NO_2 gas-sensing properties were investigated. • Bilayer graphene sensor exhibited a high linear NO_2 sensitivity of 1.409 ppm"−"1. • The NO_2-sensing mechanisms based on band diagram were highlighted. - Abstract: This work presents a highly sensitive room-temperature gas sensor based on bilayer graphene fabricated by an interfacial transfer of chemical vapor deposited graphene onto nickel interdigitated electrodes. Scanning electron microscopic and Raman spectroscopic characterizations confirm the presence of graphene on interdigitated nickel electrodes with varying numbers of graphene layers. The NO_2 detection performances of bilayer graphene gas sensor have been investigated in comparison with those of monolayer and multilayer graphene gas sensors at room temperature. From results, the bilayer graphene gas sensor exhibits higher response, sensitivity and selectivity to NO_2 than monolayer and multilayer graphene. The sensitivity of bilayer graphene gas sensor is 1.409 ppm"−"1 towards NO_2 over a concentration range of 1–25 ppm, which is more than twice higher than that of monolayer graphene. The NO_2-sensing mechanism of graphene sensing film has been explained based on the direct charge transfer process due to the adsorption of NO_2 molecules.

  11. Shield design of concrete wall between decay tank room and primary pump room in TRIGA facility

    International Nuclear Information System (INIS)

    Khan, M. J. H.; Rahman, M.; Haque, A.; Zulquarnain, A.; Ahmed, F. U.; Bhuiyan, S. I.

    2007-01-01

    The objective of this study is to recommend the radiation protection design parameters from the shielding point of view for concrete wall between the decay tank room and the primary pump room in TRIGA Mark-II research reactor facility. The shield design for this concrete wall has been performed with the help of Point-kernel Shielding Code Micro-Shield 5.05 and this design was also validated based on the measured dose rate values with Radiation Survey Meter (G-M Counter) considering the ICRP-60 (1990) recommendations for occupational dose rate limit (10 μSv/hr). The recommended shield design parameters are: (i) thickness of 114.3 cm Ilmenite-Magnetite Concrete (IMC) or 129.54 cm Ordinary Reinforced Concrete (ORC) for concrete wall A (ii) thickness of 66.04 cm Ilmenite-Magnetite Concrete (IMC) or 78.74 cm Ordinary Reinforced Concrete (ORC) for concrete wall B and (iii) door thickness of 3.175 cm Mild Steel (MS) on the entrance of decay tank room. In shielding efficiency analysis, the use of I-M concrete in the design of this concrete wall shows that it reduced the dose rate by a factor of at least 3.52 times approximately compared to ordinary reinforced concrete

  12. Criteria for the design of the control room complex for a nuclear power generating station

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This Standard addresses the central control room of a nuclear power generating station and the overall complex in which this room is housed. It is not intended to cover special or normally unattended control rooms, such as those provided for radioactive waste handling or for emergency shutdown operations. The nuclear power generating station control room complex provides a protective envelope for plant operating personnel and for instrument and control equipment vital to the operation of the plant during normal and abnormal conditions. In this capacity, the control room complex must be designed and constructed to meet the following criteria contained in Appendix A of 10CFR50, General Design criteria for Nuclear Power Plants: (1) Criterion 2: design bases for protection against natural phenomena; (2) Criterion 3: fire protection; (3) Criterion 4: environmental and missile design bases; (4) Criterion 5: sharing of structures, systems and components (multiunit stations only); and (5) Criterion 19: control room

  13. Control room habitability during severe accidents

    International Nuclear Information System (INIS)

    Siu, R.P.

    1989-01-01

    The requirements for protection of control room personnel against radiation hazards are specified in 10CFR50, Appendix A, GDC 19. The conventional approach involves a mechanistic evaluation of the radiation doses to control room personnel during design-basis accidents. In this study, an assessment of control room habitability during severe accidents is conducted. The potential levels of radiation hazards to control room personnel are evaluated in terms of both magnitude and probability of occurrence. The expected values for the probabilities of exceeding GDC-19 limits and the cumulative probability distributions of control room doses are determined. In this study, a pressurized water reactor with a large dry containment has been selected for analysis. The types of control rooms evaluated in this study include designs with: (a) filtered local intakes only, (b) filtered recirculation only, (c) filtered local intakes and recirculation, and (d) filtered dual remote intakes and recirculation. From the observations, it is concluded that, except for control room D, all other control room designs may require improvements in order to provide adequate radiation protection during severe accidents, particularly in terms of reducing whole-body gamma doses and skin doses. Potential design improvements include reduction of intake flows for concepts relying on pressurization, reduction in overall leakages, and control room pressurization through the use of bottled air supply

  14. Replacement of the Advanced Test Reactor control room

    International Nuclear Information System (INIS)

    Durney, J.L.; Klingler, W.B.

    1989-01-01

    The control room for the Advanced Test Reactor has been replaced to provide modern equipment utilizing current standards and meeting the current human factors requirements. The control room was designed in the early 1960 era and had not been significantly upgraded since the initial installation. The replacement did not change any of the safety circuits or equipment but did result in replacement of some of the recorders that display information from the safety systems. The replacement was completed in concert with the replacement of the control room simulator which provided important feedback on the design. The design successfully incorporates computer-based systems into the display of the plant variables. This improved design provides the operator with more information in a more usable form than was provided by the original design. The replacement was successfully completed within the scheduled time thereby minimizing the down time for the reactor. 1 fig., 1 tab

  15. Replacement of the Advanced Test Reactor control room

    International Nuclear Information System (INIS)

    Durney, J.L.; Klingler, W.B.

    1990-01-01

    The control room for the Advanced Test Reactor has been replaced to provide modern equipment utilizing current standards and meeting the current human factors requirements. The control room was designed in the early 1960 era and had not been significantly upgraded since the initial installation. The replacement did not change any of the safety circuits or equipment but did result in replacement of some of the recorders that display information from the safety systems. The replacement was completed in concert with the replacement of the control room simulator which provided important feedback on the design. The design successfully incorporates computer-based systems into the display of the plant variables. This improved design provides the operator with more information in a more usable form than was provided by the original design. The replacement was successfully completed within the scheduled time thereby minimizing the down time for the reactor

  16. Room Temperature Memory for Few Photon Polarization Qubits

    Science.gov (United States)

    Kupchak, Connor; Mittiga, Thomas; Jordan, Bertus; Nazami, Mehdi; Nolleke, Christian; Figueroa, Eden

    2014-05-01

    We have developed a room temperature quantum memory device based on Electromagnetically Induced Transparency capable of reliably storing and retrieving polarization qubits on the few photon level. Our system is realized in a vapor of 87Rb atoms utilizing a Λ-type energy level scheme. We create a dual-rail storage scheme mediated by an intense control field to allow storage and retrieval of any arbitrary polarization state. Upon retrieval, we employ a filtering system to sufficiently remove the strong pump field, and subject retrieved light states to polarization tomography. To date, our system has produced signal-to-noise ratios near unity with a memory fidelity of >80 % using coherent state qubits containing four photons on average. Our results thus demonstrate the feasibility of room temperature systems for the storage of single-photon-level photonic qubits. Such room temperature systems will be attractive for future long distance quantum communication schemes.

  17. Films and dark room

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After we know where the radiographic come from, then we must know about the film and also dark room. So, this chapter 5 discusses the two main components for radiography work that is film and dark room, places to process the film. Film are structured with three structured that are basic structured, emulsion and protection structured. So, this film can be classified either with their speed, screen and standard that used. The process to wash the film must be done in dark room otherwise the radiographer cannot get what are they inspected. The processing of film will be discussed briefly in next chapter.

  18. The conference hybrid control room

    International Nuclear Information System (INIS)

    Gieci, A.; Caucik, J.; Macko, J.

    2008-01-01

    An original concept of a hybrid control room was developed for the Mochovce-3 and Mochovce-4 reactor units which are under construction. The basic idea underlying the concept is that the control room should be a main working place for the operators (reactor operator and turbine operator) and for the shift supervisor, designed as a comprehensive unit desk shaped so that all members of the control room crew are in a face-to-face contact constantly. The main desk consists of three clearly identified areas serving the operators and the unit supervisor as their main working places. A soft control system is installed at the main working places. A separate safety-related working place, designed as a panel with classical instrumentations at the conference hybrid control room, is provided in case of abnormal conditions or emergency situation. Principles of ergonomics and cognitive engineering were taken into account when designing the new conference hybrid control room for the Mochovce-3 and -4 reactor units. The sizes, propositions, shapes and disposition of the equipment at the control room have been created and verified by using virtual reality tools. (orig.)

  19. Hemispherical breathing mode speaker using a dielectric elastomer actuator.

    Science.gov (United States)

    Hosoya, Naoki; Baba, Shun; Maeda, Shingo

    2015-10-01

    Although indoor acoustic characteristics should ideally be assessed by measuring the reverberation time using a point sound source, a regular polyhedron loudspeaker, which has multiple loudspeakers on a chassis, is typically used. However, such a configuration is not a point sound source if the size of the loudspeaker is large relative to the target sound field. This study investigates a small lightweight loudspeaker using a dielectric elastomer actuator vibrating in the breathing mode (the pulsating mode such as the expansion and contraction of a balloon). Acoustic testing with regard to repeatability, sound pressure, vibration mode profiles, and acoustic radiation patterns indicate that dielectric elastomer loudspeakers may be feasible.

  20. SU-F-J-44: Development of a Room Laser Based Real-Time Alignment Monitoring System Using An Array of Photodiodes

    International Nuclear Information System (INIS)

    Noh, Y; Kim, T; Kang, S; Kim, D; Cho, M; Kim, K; Shin, D; Suh, T; Kim, S

    2016-01-01

    Purpose: To develop a real-time alignment monitoring system (RAMS) to compensate for the limitations of the conventional room laser based alignment system, and to verify the feasibility of the RAMS. Methods: The RAMS was composed of a room laser sensing array (RLSA), an analog-todigital converter, and a control PC. In the RLSA, seven photodiodes (each in 1 mm width) are arranged in a pattern that the RAMS provides alignment in 1 mm resolution. It works based on detecting laser light aligned on one of photodiodes. When misaligned, the laser would match with different photodiode(s) giving signal at unexpected location. Thus, how much displaced can be determined. To verify the reproducibility of the system with respect to time as well as repeated set-ups, temporal reproducibility and repeatability test was conducted. The accuracy of the system was tested by obtaining detection signals with varying laser-match positions. Results: The signal of the RAMS was found to be stable with respect to time. The repeatability test resulted in a maximum coefficient of variance of 1.14%, suggesting that the signal of the RAMS was stable over repeated set-ups. In the accuracy test, signals between when the laser was aligned and notaligned with any of sensors could be distinguished by signal intensity. The signals of not-aligned sensors were always below 75% of the signal of the aligned sensor. It was confirmed that the system could detect 1 mm of movement by monitoring the pattern of signals, and could observe the movement of the system in real-time. Conclusion: We developed a room laser based alignment monitoring system. The feasibility test verified that the system is capable of quantitative alignment monitoring in real time. The system is relatively simple, not expensive, and considered to be easily incorporated into conventional room laser systems for real-time alignment monitoring. This research was supported by the Mid-career Researcher Program through NRF funded by the

  1. Performance-based evaluation of graphic displays for nuclear-power-plant control rooms

    International Nuclear Information System (INIS)

    Petersen, R.J.; Banks, W.W.; Gertman, D.I.

    1982-01-01

    This paper reports several methodologies for evaluating the perceptual and perceptual/decision making aspects of displays used in the control rooms of nuclear power plants. This NRC funded study focuses upon the Safety Parameter Display System (SPDS) and relates the utility of the display to objective performance and preference measures obtained in experimental conditions. The first condition is a traditional laboratory setting where classical experimental methodologies can be employed. The second condition is an interactive control room simulation where the operator's performance is assessed while he/she operates the simulator. The third condition is a rating scale designed to assess operator preferences and opinions regarding a variety of display formats. The goal of this study is the development of a cost-efficient display evaluation methodology which correlates highly with the operator's ability to control a plant

  2. Leadership in the control room

    International Nuclear Information System (INIS)

    McDougall, S.J.

    2006-01-01

    This paper discusses the importance of leadership within the control rooms at nuclear power facilities. the leadership capability of control room staff has a significant influence over the improvement of human performance and the development of an 'event free' culture within the business. The development of leadership competency in the control room must be an important part of any nuclear power utility business improvement plan. (author)

  3. Development, validation and testing of a nursing home to emergency room transfer checklist.

    Science.gov (United States)

    Tsai, Hsiu-Hsin; Tsai, Yun-Fang

    2018-01-01

    To develop and test the feasibility of an instrument to support patients' nursing home to emergency room transfer. Transfers from a nursing home care facility to an acute care facility such as a hospital emergency room are common. However, the prevalence of an information gap for transferring residents' health data to acute care facility is high. An evidence-based transfer instrument, which could fill this gap, is lacking. Development of a nursing home to emergency room transfer checklist, validation of items using the Delphi method and testing the feasibility and benefits of using the nursing home to emergency room transfer checklist. Items were developed based on qualitative data from previous research. Delphi validation, retrospective chart review (baseline data) and a 6-month prospective study design were applied to test the feasibility of using the checklist. Variables for testing the feasibility of the checklist included residents' 30-day readmission rate and length of hospital stay. Development of the nursing home to emergency room transfer checklist resulted in four main parts: (i) demographic data of the nursing home resident; (ii) critical data for nursing home to emergency room transfer; (iii) contact information and (iv) critical data for emergency room to nursing home transfer. Two rounds of Delphi validation resulted in a mean score (standard deviation) ranging from 4.39 (1.13)-4.98 (.15). Time required to complete the checklist was 3-5 min. Use of the nursing home to emergency room transfer checklist resulted in a 30-day readmission rate of 13.4%, which was lower than the baseline rate of 15.9%. The nursing home to emergency room transfer checklist was developed for transferring nursing home residents to an emergency room. The instrument was found to be an effective tool for this process. Use of the nursing home to emergency room transfer checklist for nursing home transfers could fill the information gap that exists when transferring older adults

  4. Operating room manager game

    NARCIS (Netherlands)

    Hans, Elias W.; Nieberg, T.

    2007-01-01

    The operating room (OR) department of a hospital forms the heart of the organization, where the single largest cost is incurred. This document presents and reports on the “Operating Room Manager Game,” developed to give insight into managing a large hospital's OR department at various levels of

  5. Leadership in the control room

    Energy Technology Data Exchange (ETDEWEB)

    McDougall, S.J. [Bruce Power, Bruce B Operations Div., Tiverton, Ontario (Canada)

    2006-07-01

    This paper discusses the importance of leadership within the control rooms at nuclear power facilities. the leadership capability of control room staff has a significant influence over the improvement of human performance and the development of an 'event free' culture within the business. The development of leadership competency in the control room must be an important part of any nuclear power utility business improvement plan. (author)

  6. Effect of an Ergonomics-Based Educational Intervention Based on Transtheoretical Model in Adopting Correct Body Posture Among Operating Room Nurses.

    Science.gov (United States)

    Moazzami, Zeinab; Dehdari, Tahere; Taghdisi, Mohammad Hosein; Soltanian, Alireza

    2015-11-03

    One of the preventive strategies for chronic low back pain among operating room nurses is instructing proper body mechanics and postural behavior, for which the use of the Transtheoretical Model (TTM) has been recommended. Eighty two nurses who were in the contemplation and preparation stages for adopting correct body posture were randomly selected (control group = 40, intervention group = 42). TTM variables and body posture were measured at baseline and again after 1 and 6 months after the intervention. A four-week ergonomics educational intervention based on TTM variables was designed and conducted for the nurses in the intervention group. Following the intervention, a higher proportion of nurses in the intervention group moved into the action stage (p 0.05) after the intervention. The TTM provides a suitable framework for developing stage-based ergonomics interventions for postural behavior.

  7. Room temperature chemical synthesis of highly oriented PbSe nanotubes based on negative free energy of formation

    Energy Technology Data Exchange (ETDEWEB)

    Sankapal, B.R., E-mail: brsankapal@rediffmail.com [Thin Film and Nano Science Laboratory, Department of Physics, School of Physical Sciences, North Maharashtra University, Jalgaon 425 001 (MS) (India); Ladhe, R.D.; Salunkhe, D.B.; Baviskar, P.K. [Thin Film and Nano Science Laboratory, Department of Physics, School of Physical Sciences, North Maharashtra University, Jalgaon 425 001 (MS) (India); Gupta, V.; Chand, S. [Organic and Hybrid Solar Cell, Physics of Energy Harvesting Division, Dr. K.S. Krishnan Marg, National Physical Laboratory, New Delhi 110012 (India)

    2011-10-13

    Highlights: > Simple, inexpensive and room temperature chemical synthesis route. > Highly oriented PbSe nanotubes from Cd(OH){sub 2} nanowires through lead hydroxination. > The process was template free without the use of any capping agent. > Reaction kinetics was accomplished due to more negative free energy of formation. > The ion exchange mechanism due to difference in the solubility products. - Abstract: The sacrificial template free chemical synthesis of PbSe nanotubes at room temperature has been performed by lead hydroxination from cadmium hydroxide nanowires. This process was based on the ion exchange reaction to replace Cd{sup 2+} with Pb{sup 2+} ions from hydroxyl group followed by replacement of hydroxyl group with selenium ions. The reaction kinetics was accomplished due to more negative free energy of formation and thus the difference in the solubility products. The formed nanotubes were inclusive of Pb and Se with proper inter-chemical bonds with preferred orientations having diameter in tens of nanometer. These nanotubes can have future applications in electronic, optoelectronics and photovoltaic's as well.

  8. Room temperature chemical synthesis of highly oriented PbSe nanotubes based on negative free energy of formation

    International Nuclear Information System (INIS)

    Sankapal, B.R.; Ladhe, R.D.; Salunkhe, D.B.; Baviskar, P.K.; Gupta, V.; Chand, S.

    2011-01-01

    Highlights: → Simple, inexpensive and room temperature chemical synthesis route. → Highly oriented PbSe nanotubes from Cd(OH) 2 nanowires through lead hydroxination. → The process was template free without the use of any capping agent. → Reaction kinetics was accomplished due to more negative free energy of formation. → The ion exchange mechanism due to difference in the solubility products. - Abstract: The sacrificial template free chemical synthesis of PbSe nanotubes at room temperature has been performed by lead hydroxination from cadmium hydroxide nanowires. This process was based on the ion exchange reaction to replace Cd 2+ with Pb 2+ ions from hydroxyl group followed by replacement of hydroxyl group with selenium ions. The reaction kinetics was accomplished due to more negative free energy of formation and thus the difference in the solubility products. The formed nanotubes were inclusive of Pb and Se with proper inter-chemical bonds with preferred orientations having diameter in tens of nanometer. These nanotubes can have future applications in electronic, optoelectronics and photovoltaic's as well.

  9. Toward feasible, valid, and reliable video-based assessments of technical surgical skills in the operating room

    DEFF Research Database (Denmark)

    Aggarwal, R.; Grantcharov, T.; Moorthy, K.

    2008-01-01

    .72). Conclusions: Video-based technical skills evaluation in the operating room is feasible, valid and reliable. Global rating scales hold promise for summative assessment, though further work is necessary to elucidate the value of procedural rating scales Udgivelsesdato: 2008/2......Objective: To determine the feasibility, validity, inter-rater, and intertest reliability of 4 previously published video-based rating scales, for technical skills assessment on a benchmark laparoscopic procedure. Summary Background Data: Assessment of technical skills is crucial...... to the demonstration and maintenance of competent healthcare practitioners. Traditional assessment methods are prone to subjectivity through a lack of proven validity and reliability. Methods: Nineteen surgeons (6 novice and 13 experienced) performed a median of 2 laparoscopic cholecystectomies each (range 1-5) on 53...

  10. Reproduction of Realistic Background Noise for Testing Telecommunications Devices

    DEFF Research Database (Denmark)

    Gil Corrales, Juan David; Song, Wookeun; MacDonald, Ewen

    2015-01-01

    A method for reproduction of sound, based on crosstalk cancellation using inverse filters, was implemented in the context of testing telecommunications devices. The effect of the regularization parameter, number of loudspeakers, type of background noise, and a technique to attenuate audible......, the performance was equally good when using eight or four loudspeakers, and the reproduction method was shown to be robust for different program materials. The proposed technique to reduce audible artifacts increased the perceived similarity....

  11. Strategies for increasing the feasibility of performance assessments during competency-based education: Subjective and objective evaluations correlate in the operating room.

    Science.gov (United States)

    Szasz, Peter; Louridas, Marisa; Harris, Kenneth A; Grantcharov, Teodor P

    2017-08-01

    Competency-based education necessitates assessments that determine whether trainees have acquired specific competencies. The evidence on the ability of internal raters (staff surgeons) to provide accurate assessments is mixed; however, this has not yet been directly explored in the operating room. This study's objective is to compare the ratings given by internal raters vs an expert external rater (independent to the training process) in the operating room. Raters assessed general surgery residents during a laparoscopic cholecystectomy for their technical and nontechnical performance. Fifteen cases were observed. There was a moderately positive correlation (r s = .618, P = .014) for technical performance and a strong positive correlation (r s = .731, P = .002) for nontechnical performance. The internal raters were less stringent for technical (mean rank 3.33 vs 8.64, P = .007) and nontechnical (mean rank 3.83 vs 8.50, P = .01) performances. This study provides evidence to help operationalize competency-based assessments. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. The research and application of green computer room environmental monitoring system based on internet of things technology

    Science.gov (United States)

    Wei, Wang; Chongchao, Pan; Yikai, Liang; Gang, Li

    2017-11-01

    With the rapid development of information technology, the scale of data center increases quickly, and the energy consumption of computer room also increases rapidly, among which, energy consumption of air conditioning cooling makes up a large proportion. How to apply new technology to reduce the energy consumption of the computer room becomes an important topic of energy saving in the current research. This paper study internet of things technology, and design a kind of green computer room environmental monitoring system. In the system, we can get the real-time environment data from the application of wireless sensor network technology, which will be showed in a creative way of three-dimensional effect. In the environment monitor, we can get the computer room assets view, temperature cloud view, humidity cloud view, microenvironment view and so on. Thus according to the condition of the microenvironment, we can adjust the air volume, temperature and humidity parameters of the air conditioning for the individual equipment cabinet to realize the precise air conditioning refrigeration. And this can reduce the energy consumption of air conditioning, as a result, the overall energy consumption of the green computer room will reduce greatly. At the same time, we apply this project in the computer center of Weihai, and after a year of test and running, we find that it took a good energy saving effect, which fully verified the effectiveness of this project on the energy conservation of the computer room.

  13. Enhancement of NH3 Gas Sensitivity at Room Temperature by Carbon Nanotube-Based Sensor Coated with Co Nanoparticles

    Directory of Open Access Journals (Sweden)

    Lich Quang Nguyen

    2013-01-01

    Full Text Available Multi-walled carbon nanotube (MWCNT film has been fabricated onto Pt-patterned alumina substrates using the chemical vapor deposition method for NH3 gas sensing applications. The MWCNT-based sensor is sensitive to NH3 gas at room temperature. Nanoclusters of Co catalysts have been sputtered on the surface of the MWCNT film to enhance gas sensitivity with respect to unfunctionalized CNT films. The gas sensitivity of Co-functionalized MWCNT-based gas sensors is thus significantly improved. The sensor exhibits good repeatability and high selectivity towards NH3, compared with alcohol and LPG.

  14. 32 CFR 518.9 - Reading room.

    Science.gov (United States)

    2010-07-01

    ... RELATIONS THE FREEDOM OF INFORMATION ACT PROGRAM FOIA Reading Rooms § 518.9 Reading room. (a) Reading room... clearly unwarranted invasions of privacy, or competitive harm to business submitters. In appropriate cases... information concerning munitions, equipment, systems, and intelligence activities. (4) (a)(2)(D) records...

  15. 7 CFR 58.312 - Churn rooms.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Churn rooms. 58.312 Section 58.312 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....312 Churn rooms. Churn rooms in addition to proper construction and sanitation shall be so equipped...

  16. The Mechanism of Room-Temperature Ionic-Liquid-Based Electrochemical CO₂ Reduction: A Review.

    Science.gov (United States)

    Lim, Hyung-Kyu; Kim, Hyungjun

    2017-03-28

    Electrochemical CO₂ conversion technology is becoming indispensable in the development of a sustainable carbon-based economy. While various types of electrocatalytic systems have been designed, those based on room-temperature ionic liquids (RTILs) have attracted considerable attention because of their high efficiencies and selectivities. Furthermore, it should be possible to develop more advanced electrocatalytic systems for commercial use because target-specific characteristics can be fine-tuned using various combinations of RTIL ions. To achieve this goal, we require a systematic understanding of the role of the RTIL components in electrocatalytic systems, however, their role has not yet been clarified by experiment or theory. Thus, the purpose of this short review is to summarize recent experimental and theoretical mechanistic studies to provide insight into and to develop guidelines for the successful development of new CO₂ conversion systems. The results discussed here can be summarized as follows. Complex physical and chemical interactions between the RTIL components and the reaction intermediates, in particular at the electrode surface, are critical for determining the activity and selectivity of the electrocatalytic system, although no single factor dominates. Therefore, more fundamental research is required to understand the physical, chemical, and thermodynamic characteristics of complex RTIL-based electrocatalytic systems.

  17. Measures of Rehospitalization, Emergency Room Visit, and Community Discharge

    Data.gov (United States)

    U.S. Department of Health & Human Services — Measures of the Rate of Rehospitalization, Emergency Room Visit, and Community Discharge for Medicare Beneficiaries. These rates are based on Medicare claims data.

  18. Perceived spatial positioning of self-footstep sounds in three surround sound speaker setups for immersive virtual reality

    DEFF Research Database (Denmark)

    Sikström, Erik; Nilsson, Niels Christian; Nordahl, Rolf

    2013-01-01

    Are there differences in how well loudspeaker setups are able to provide a believable illusion of footstep sounds originating from the user of an immersive virtual reality? To investigate this performance in spatial positioning via loudspeakers, a comparison of the three surround sound loudspeaker...

  19. Wind tunnel testing to predict control room atmospheric dispersion factors

    International Nuclear Information System (INIS)

    Holmquist, L.J.; Harden, P.A.; Muraida, J.E.

    1993-01-01

    Recent concerns at Palisades about control room habitability in the event of a loss-of-coolant accident have led to an extensive effort to increase control room habitability margin. The heating, ventilating and air-conditioning (HVAC) system servicing the control room has the potential for unfiltered in-leakage through its normal outside air intake louvered isolation dampers during emergency mode. The current limiting control room habitability analysis allows for 1.2 x 10 -2 m 3 /s (25 ft 3 /min) unfiltered in-leakage into the control room envelope. This leakage value was not thought to be achievable with the existing as-built configuration. Repairing the system was considered as a potential solution; however, this would be costly and could negatively affect plant operation. In addition, the system would still be required to meet the low specified unfiltered in-leakage. A second approach to this problem was to determine the atmospheric dispersion factors (x/Q's) through a wind tunnel test using a scale model of Palisades. The results of the wind tunnel testing could yield more realistic x/Q's for control room habitability than previously employed methods. Palisades selected the wind tunnel study option based on its ease of implementation, realistic results, and low cost. More importantly, the results of the study could increase the allowable unfiltered in-leakage

  20. Manufacturing of NAA laboratory clean room

    International Nuclear Information System (INIS)

    Suwoto; Hasibuan, Djaruddin

    2001-01-01

    The ''NAA laboratory clean room'' has been built in the Reactor Serba Guna G.A. Siwabessy building. The erection of ''AAN laboratory clean room'' doing by started of preparation of the ''manufacturing procedure'' refer to ''Design and manufacturing neutron activation analysis clean room laboratory''. Manufacturing process and erection doing refer to procedures makes. By providing of the ''AAN laboratory clean room'' can be cocluded that the research activity and the user sevises in P2TRR well meet to be done

  1. Radiation shielding design of BNCT treatment room for D-T neutron source.

    Science.gov (United States)

    Pouryavi, Mehdi; Farhad Masoudi, S; Rahmani, Faezeh

    2015-05-01

    Recent studies have shown that D-T neutron generator can be used as a proper neutron source for Boron Neutron Capture Therapy (BNCT) of deep-seated brain tumors. In this paper, radiation shielding calculations have been conducted based on the computational method for designing a BNCT treatment room for a recent proposed D-T neutron source. By using the MCNP-4C code, the geometry of the treatment room has been designed and optimized in such a way that the equivalent dose rate out of the treatment room to be less than 0.5μSv/h for uncontrolled areas. The treatment room contains walls, monitoring window, maze and entrance door. According to the radiation protection viewpoint, dose rate results of out of the proposed room showed that using D-T neutron source for BNCT is safe. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Auditory modelling for assessing room acoustics

    NARCIS (Netherlands)

    Van Dorp Schuitman, J.

    2011-01-01

    The acoustics of a concert hall, or any other room, are generally assessed by measuring room impulse responses for one or multiple source and receiver location(s). From these responses, objective parameters can be determined that should be related to various perceptual attributes of room acoustics.

  3. Convection From a Slender Cylender in a Ventilated Room

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Sandberg, M.

    1990-01-01

    with measurements in the boundary layer flow around a heated vertical slender cylinder in a full-scale test room with displacement ventilation. Both velocity and temperature profiles in the boundary layer flow were recorded. The room was ventilated by a low velocity diffuser, standing on the floor, from which air......The equations, based on an integral formulation, for turbulent natural boundary layer flow are solved in both the constant temperature case and in the constant heat flux case. Solutions are found. for convection along both flat plates and cylinders. Theoretical predictions are compared...... with a negative buoyancy was supplied. The vertical distribution of both temperature and contamination in the room was measured as a function of the heat load and the air flow rate. The contaminant distribution showed a clear stratification between clean and contaminated air, while the temperature was increasing...

  4. Cultural differences in room size perception.

    Science.gov (United States)

    Saulton, Aurelie; Bülthoff, Heinrich H; de la Rosa, Stephan; Dodds, Trevor J

    2017-01-01

    Cultural differences in spatial perception have been little investigated, which gives rise to the impression that spatial cognitive processes might be universal. Contrary to this idea, we demonstrate cultural differences in spatial volume perception of computer generated rooms between Germans and South Koreans. We used a psychophysical task in which participants had to judge whether a rectangular room was larger or smaller than a square room of reference. We systematically varied the room rectangularity (depth to width aspect ratio) and the viewpoint (middle of the short wall vs. long wall) from which the room was viewed. South Koreans were significantly less biased by room rectangularity and viewpoint than their German counterparts. These results are in line with previous notions of general cognitive processing strategies being more context dependent in East Asian societies than Western ones. We point to the necessity of considering culturally-specific cognitive processing strategies in visual spatial cognition research.

  5. Cultural differences in room size perception.

    Directory of Open Access Journals (Sweden)

    Aurelie Saulton

    Full Text Available Cultural differences in spatial perception have been little investigated, which gives rise to the impression that spatial cognitive processes might be universal. Contrary to this idea, we demonstrate cultural differences in spatial volume perception of computer generated rooms between Germans and South Koreans. We used a psychophysical task in which participants had to judge whether a rectangular room was larger or smaller than a square room of reference. We systematically varied the room rectangularity (depth to width aspect ratio and the viewpoint (middle of the short wall vs. long wall from which the room was viewed. South Koreans were significantly less biased by room rectangularity and viewpoint than their German counterparts. These results are in line with previous notions of general cognitive processing strategies being more context dependent in East Asian societies than Western ones. We point to the necessity of considering culturally-specific cognitive processing strategies in visual spatial cognition research.

  6. A room of one's own--Being cared for in a hospital with a single-bed room design.

    Science.gov (United States)

    Persson, Eva; Anderberg, Patrice; Ekwall, Anna Kristensson

    2015-06-01

    To illuminate patients' experiences of being hospitalised in a hospital with a single-bed room design. Many patients seem to prefer single-bed hospital rooms. However, studies have also shown that patients do see the advantages of multiple-bed rooms. Interviews were conducted with 16 inpatients from a surgical ward in a hospital building with a single-bed room design. A hermeneutical-phenomenological approach guided by van Manen's four life-world existentials was used to analyse the interviews. The essential meaning was that patients felt secure because they could create a personal environment without disruptive elements. The room was private, and this implied feelings of homeliness, which allowed patients to focus on themselves and was thought to facilitate the recovery process. The patients preferred staying in their room, and the relationship with the personnel was central. Feelings of loneliness and isolation could occur and could be frightening. Being hospitalised in a single-bed room meant balancing between feeling secure and feeling insecure. The following four themes emerged: A homely environment, The need for company and security, Time as unpredictable and involving waiting and Focus on healing the body. Patients experienced that a single-bed room allowed them to focus on their recovery, have visitors without disturbing others and create a feeling of homeliness. However, mobilisation is not a natural part of the recovery process when patients have all they need in their rooms. The patients' need for social interaction and confirmation was not satisfied without effort and planning on the part of staff. © 2014 Nordic College of Caring Science.

  7. 3D Room Visualization on Android Based Mobile Device (with Philips™’ Surround Sound Music Player

    Directory of Open Access Journals (Sweden)

    Durio Etgar

    2012-12-01

    Full Text Available This project’s specifically purposed as a demo application, so anyone can get the experience of a surround audio room without having to physically involved to it, with a main idea of generating a 3D surround sound room scenery coupled with surround sound in a handier package, namely, a “Virtual Listen Room”. Virtual Listen Room set a foundation of an innovative visualization that later will be developed and released as one of way of portable advertisement. This application was built inside of Android environment. Android device had been chosen as the implementation target, since it leaves massive development spaces and mostly contains essential components needed on this project, including graphic processor unit (GPU.  Graphic manipulation can be done using an embedded programming interface called OpenGL ES, which is planted in all Android devices generally. Further, Android has a Accelerometer Sensor that is needed to be coupled with scene to produce a dynamic movement of the camera. Surround sound effect can be reached with a decoder from Phillips called MPEG Surround Sound Decoder. To sum the whole project, we got an application with sensor-dynamic 3D room visualization coupled with Philips’ Surround Sound Music Player. We can manipulate several room’s properties; Subwoofer location, Room light, and how many speakers inside it, the application itself works well despite facing several performance problems before, later to be solved. [Keywords : Android,Visualization,Open GL; ES; 3D; Surround Sensor

  8. 3D Room Visualization on Android Based Mobile Device (with Philips™’ Surround Sound Music Player

    Directory of Open Access Journals (Sweden)

    Durio Etgar

    2013-01-01

    Full Text Available This project’s specifically purposed as a demo application, so anyone can get the experience of a surround audio room without having to physically involved to it, with a main idea of generating a 3D surround sound room scenery coupled with surround sound in a handier package, namely, a “Virtual Listen Room”. Virtual Listen Room set a foundation of an innovative visualization that later will be developed and released as one of way of portable advertisement. This application was built inside of Android environment. Android device had been chosen as the implementation target, since it leaves massive development spaces and mostly contains essential components needed on this project, including graphic processor unit (GPU. Graphic manipulation can be done using an embedded programming interface called OpenGL ES, which is planted in all Android devices generally. Further, Android has a Accelerometer Sensor that is needed to be coupled with scene to produce a dynamic movement of the camera. Surround sound effect can be reached with a decoder from Phillips called MPEG Surround Sound Decoder. To sum the whole project, we got an application with sensor-dynamic 3D room visualization coupled with Philips’ Surround Sound Music Player. We can manipulate several room’s properties; Subwoofer location, Room light, and how many speakers inside it, the application itself works well despite facing several performance problems before, later to be solved.

  9. Energy Efficiency in Small Server Rooms: Field Surveys and Findings

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Iris [Hoi; Greenberg, Steve; Mahdavi, Roozbeh; Brown, Richard; Tschudi, William

    2014-08-11

    Fifty-seven percent of US servers are housed in server closets, server rooms, and localized data centers, in what are commonly referred to as small server rooms, which comprise 99percent of all server spaces in the US. While many mid-tier and enterprise-class data centers are owned by large corporations that consider energy efficiency a goal to minimize business operating costs, small server rooms typically are not similarly motivated. They are characterized by decentralized ownership and management and come in many configurations, which creates a unique set of efficiency challenges. To develop energy efficiency strategies for these spaces, we surveyed 30 small server rooms across eight institutions, and selected four of them for detailed assessments. The four rooms had Power Usage Effectiveness (PUE) values ranging from 1.5 to 2.1. Energy saving opportunities ranged from no- to low-cost measures such as raising cooling set points and better airflow management, to more involved but cost-effective measures including server consolidation and virtualization, and dedicated cooling with economizers. We found that inefficiencies mainly resulted from organizational rather than technical issues. Because of the inherent space and resource limitations, the most effective measure is to operate servers through energy-efficient cloud-based services or well-managed larger data centers, rather than server rooms. Backup power requirement, and IT and cooling efficiency should be evaluated to minimize energy waste in the server space. Utility programs are instrumental in raising awareness and spreading technical knowledge on server operation, and the implementation of energy efficiency measures in small server rooms.

  10. ALICE’s new meeting room

    CERN Multimedia

    2009-01-01

    There’s no reason to be late for a meeting in Wonderland (Point 2) anymore as ALICE gets a brand new conference room and a ‘clean up’. The new ALICE conference room.You won’t find Building 3294 on the CERN map yet, but it is already being used. If you follow the white rabbit just inside the entrance at point 2, you will find a new conference room and office space for 12 people. "Previously at Point 2 we’ve had very little office space at all. Our old conference room was inside the main building, SX2, but it was cramped and extremely noisy," explained Frank Cliff from ALICE. "As soon as they turned on the overhead cranes you could barely hear yourself think!" The plans for the new building were drawn up by the Civil Engineering Group, and construction started in August last year. The building was completed and already in use before Christmas. The 109 square metre conference room can fit up to 60 people and is fully equipped...

  11. Statistical Modeling of Ultrawideband Body-Centric Wireless Channels Considering Room Volume

    Directory of Open Access Journals (Sweden)

    Miyuki Hirose

    2012-01-01

    Full Text Available This paper presents the results of a statistical modeling of onbody ultrawideband (UWB radio channels for wireless body area network (WBAN applications. Measurements were conducted in five different rooms. A measured delay profile can be divided into two domains; in the first domain (04 ns has multipath components that are dominant and dependent on room volume. The first domain was modeled with a conventional power decay law model, and the second domain with a modified Saleh-Valenzuela model considering the room volume. Realizations of the impulse responses are presented based on the composite model and compared with the measured average power delay profiles.

  12. Preliminary evaluation of sweet spot size in virtual sound reproduction using dipoles

    DEFF Research Database (Denmark)

    Lacouture Parodi, Yesenia; Rubak, Per

    2009-01-01

    to the loudspeakers. In this paper we present a follow up evaluation of the performance of the three inversion techniques when these conditions are violated. A setup to measure the sweet spot of different loudspeakers arrangements is described. Preliminary measurement results are presented for loudspeakers placed...

  13. Low Cycle Fatigue Behavior of Alloy 617 Base Metal and Welded Joints at Room Temperature and 850 .deg. C for VHTR Applications

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seon Jin; Dew, Rando T. [Pukyong National Univ., Busan (Korea, Republic of); Kim, Woo Gon; Kim, Min Hwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Low cycle fatigue (LCF) is an important design consideration for high temperature IHX components. Moreover, some of the components are joined by welding techniques and therefore the welded joints are unavoidable in the construction of mechanical structures. Since Alloy 617 was introduced in early 1970s, many attempts have been made in the past two decades to evaluate the LCF and creep-fatigue behavior in Alloy 617 base metal at room temperature and high temperature. However, little research has focused on the evaluation and characterization of the Alloy 617 welded joints. butt-welded joint specimens was performed at room temperature and 850 .deg. C. Fatigue lives of GTAW welded joint specimens were lower than those of base metal specimens. LCF cracking and failure in welded specimens initiated in the weld metal zone and followed transgranluar dendritic paths for both at RT and 850 .deg. C.

  14. Highly sensitive and selective room-temperature NO{sub 2} gas sensor based on bilayer transferred chemical vapor deposited graphene

    Energy Technology Data Exchange (ETDEWEB)

    Seekaew, Yotsarayuth [Department of Physics, Faculty of Science, Kasetsart University, Chatuchak, Bangkok 10900 (Thailand); Phokharatkul, Ditsayut; Wisitsoraat, Anurat [Nanoelectronics and MEMS Laboratory, National Electronics and Computer Technology Center, Klong Luang, Pathumthani 12120 (Thailand); Wongchoosuk, Chatchawal, E-mail: chatchawal.w@ku.ac.th [Department of Physics, Faculty of Science, Kasetsart University, Chatuchak, Bangkok 10900 (Thailand)

    2017-05-15

    Highlights: • Simple and low-cost fabrication of bilayer graphene gas sensor was presented. • Layer effects of graphene on NO{sub 2} gas-sensing properties were investigated. • Bilayer graphene sensor exhibited a high linear NO{sub 2} sensitivity of 1.409 ppm{sup −1}. • The NO{sub 2}-sensing mechanisms based on band diagram were highlighted. - Abstract: This work presents a highly sensitive room-temperature gas sensor based on bilayer graphene fabricated by an interfacial transfer of chemical vapor deposited graphene onto nickel interdigitated electrodes. Scanning electron microscopic and Raman spectroscopic characterizations confirm the presence of graphene on interdigitated nickel electrodes with varying numbers of graphene layers. The NO{sub 2} detection performances of bilayer graphene gas sensor have been investigated in comparison with those of monolayer and multilayer graphene gas sensors at room temperature. From results, the bilayer graphene gas sensor exhibits higher response, sensitivity and selectivity to NO{sub 2} than monolayer and multilayer graphene. The sensitivity of bilayer graphene gas sensor is 1.409 ppm{sup −1} towards NO{sub 2} over a concentration range of 1–25 ppm, which is more than twice higher than that of monolayer graphene. The NO{sub 2}-sensing mechanism of graphene sensing film has been explained based on the direct charge transfer process due to the adsorption of NO{sub 2} molecules.

  15. An Optimisation Approach for Room Acoustics Design

    DEFF Research Database (Denmark)

    Holm-Jørgensen, Kristian; Kirkegaard, Poul Henning; Andersen, Lars

    2005-01-01

    This paper discuss on a conceptual level the value of optimisation techniques in architectural acoustics room design from a practical point of view. It is chosen to optimise one objective room acoustics design criterium estimated from the sound field inside the room. The sound field is modeled...... using the boundary element method where absorption is incorporated. An example is given where the geometry of a room is defined by four design modes. The room geometry is optimised to get a uniform sound pressure....

  16. Best-effort Support for a Virtual Seminar Room

    DEFF Research Database (Denmark)

    Sharp, Robin; Todirica, Edward Alexandru

    2002-01-01

    This paper describes the RTMM Virtual Seminar Room, an interactive distributed multimedia application based on a platform with a simple middleware architecture, using best effort scheduling and a best effort network service. Emphasis has been placed on achieving low latency in all parts...

  17. Highly selective room temperature NO2 gas sensor based on rGO-ZnO composite

    Science.gov (United States)

    Jyoti, Kanaujiya, Neha; Varma, G. D.

    2018-05-01

    Blending metal oxide nanoparticles with graphene or its derivatives can greatly enhance gas sensing characteristics. In the present work, ZnO nanoparticles have been synthesized via reflux method. Thin films of reduced graphene oxide (rGO) and composite of rGO-ZnO have been fabricated by drop casting method for gas sensing application. The samples have been characterized by X-ray diffraction (XRD) and Field-emission scanning electron microscope (FESEM) for the structural and morphological studies respectively. Sensing measurements have been carried out for the composite film of rGO-ZnO for different concentrations of NO2 ranging from 4 to 100 ppm. Effect of increasing temperature on the sensing performance has also been studied and the rGO-ZnO composite sensor shows maximum percentage response at room temperature. The limit of detection (LOD) for rGO-ZnO composite sensor is 4ppm and it exhibits a high response of 48.4% for 40 ppm NO2 at room temperature. To check the selectivity of the composite sensor, sensor film has been exposed to 40 ppm different gases like CO, NH3, H2S and Cl2 at room temperature and the sensor respond negligibly to these gases. The present work suggests that rGO-ZnO composite material can be a better candidate for fabrication of highly selective room temperature NO2 gas sensor.

  18. Efficient room temperature hydrogen sensor based on UV-activated ZnO nano-network

    Science.gov (United States)

    Kumar, Mohit; Kumar, Rahul; Rajamani, Saravanan; Ranwa, Sapana; Fanetti, Mattia; Valant, Matjaz; Kumar, Mahesh

    2017-09-01

    Room temperature hydrogen sensors were fabricated from Au embedded ZnO nano-networks using a 30 mW GaN ultraviolet LED. The Au-decorated ZnO nano-networks were deposited on a SiO2/Si substrate by a chemical vapour deposition process. X-ray diffraction (XRD) spectrum analysis revealed a hexagonal wurtzite structure of ZnO and presence of Au. The ZnO nanoparticles were interconnected, forming nano-network structures. Au nanoparticles were uniformly distributed on ZnO surfaces, as confirmed by FESEM imaging. Interdigitated electrodes (IDEs) were fabricated on the ZnO nano-networks using optical lithography. Sensor performances were measured with and without UV illumination, at room temperate, with concentrations of hydrogen varying from 5 ppm to 1%. The sensor response was found to be ˜21.5% under UV illumination and 0% without UV at room temperature for low hydrogen concentration of 5 ppm. The UV-photoactivated mode enhanced the adsorption of photo-induced O- and O2- ions, and the d-band electron transition from the Au nanoparticles to ZnO—which increased the chemisorbed reaction between hydrogen and oxygen. The sensor response was also measured at 150 °C (without UV illumination) and found to be ˜18% at 5 ppm. Energy efficient low cost hydrogen sensors can be designed and fabricated with the combination of GaN UV LEDs and ZnO nanostructures.

  19. OMNIDIRECTIONAL SOUND SOURCE

    DEFF Research Database (Denmark)

    1996-01-01

    A sound source comprising a loudspeaker (6) and a hollow coupler (4) with an open inlet which communicates with and is closed by the loudspeaker (6) and an open outlet, said coupler (4) comprising rigid walls which cannot respond to the sound pressures produced by the loudspeaker (6). According...

  20. Birth room images

    DEFF Research Database (Denmark)

    Bowden, Calida; Sheehan, Athena; Foureur, Maralyn Jean

    2016-01-01

    Objective: this study examined images of birth rooms in developed countries to analyse the messages and visual discourse being communicated through images. Design: a small qualitative study using Kress and van Leeuwen's (2006) social semiotic theoretical framework for image analysis, a form...... and implications for practice: as images on the Internet inform and persuade society about stereotypical behaviours, the trends of our time and sociocultural norms, it is important to recognise images of the technological birth room on the Internet may be influential in dictating women's attitudes, choices...